Sample records for simulated tear fluid

  1. A two-fluid study of oblique tearing modes in a force-free current sheet

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Akçay, Cihan, E-mail: akcay@lanl.gov; Daughton, William; Lukin, Vyacheslav S.

    2016-01-15

    Kinetic simulations have demonstrated that three-dimensional reconnection in collisionless regimes proceeds through the formation and interaction of magnetic flux ropes, which are generated due to the growth of tearing instabilities at multiple resonance surfaces. Since kinetic simulations are intrinsically expensive, it is desirable to explore the feasibility of reduced two-fluid models to capture this complex evolution, particularly, in the strong guide field regime, where two-fluid models are better justified. With this goal in mind, this paper compares the evolution of the collisionless tearing instability in a force-free current sheet with a two-fluid model and fully kinetic simulations. Our results indicatemore » that the most unstable modes are oblique for guide fields larger than the reconnecting field, in agreement with the kinetic results. The standard two-fluid tearing theory is extended to address the tearing instability at oblique angles. The resulting theory yields a flat oblique spectrum and underestimates the growth of oblique modes in a similar manner to kinetic theory relative to kinetic simulations.« less

  2. A two-fluid study of oblique tearing modes in a force-free current sheet

    DOE PAGES

    Akçay, Cihan; Daughton, William; Lukin, Vyacheslav S.; ...

    2016-01-01

    Kinetic simulations have demonstrated that three-dimensional reconnection in collisionless regimes proceeds through the formation and interaction of magnetic flux ropes, which are generated due to the growth of tearing instabilities at multiple resonance surfaces. Because kinetic simulations are intrinsically expensive, it is desirable to explore the feasibility of reduced two-fluid models to capture this complex evolution, particularly, in the strong guide field regime, where two-fluid models are better justified. With this goal in mind, this paper compares the evolution of the collisionless tearing instability in a force-free current sheet with a two-fluid model and fully kinetic simulations. Our results indicatemore » that the most unstable modes are oblique for guide fields larger than the reconnecting field, in agreement with the kinetic results. The standard two-fluid tearing theory is extended to address the tearing instability at oblique angles. As a results this theory yields a flat oblique spectrum and underestimates the growth of oblique modes in a similar manner to kinetic theory relative to kinetic simulations.« less

  3. A MODEL FOR THE TEAR FILM AND OCULAR SURFACE TEMPERATURE FOR PARTIAL BLINKS

    PubMed Central

    Deng, Quan; Braun, R. J.; Driscoll, T. A.; King-Smith, P. E.

    2015-01-01

    In this paper, we investigate the dynamics of tear film and the associated temperature variation for partial blinks. We investigate the mechanism of fluid supply during partial blink cycles, and compare the film thickness with observation in vivo. We find that varying the thickness of the fluid layer beneath the moving upper lid improves the agreement for the in vivo measurement of tear film thickness after a half blink. By examining the flux of the fluid, we provide an explanation of this assumption. We also investigate the temperature dynamics both at the ocular surface and inside the simulated anterior chamber. Our simulation results suggest that the ocular surface temperature readjusts rapidly to normal temperature distribution after partial blinks. PMID:25635242

  4. Characterization of drug release from liposomal formulations in ocular fluid.

    PubMed

    Jafari, M R; Jones, A B; Hikal, A H; Williamson, J S; Wyandt, C M

    1998-01-01

    The successful application of liposomes in topical ophthalmic drug delivery requires knowledge of vesicle stabilization in the presence of tear fluid. The release of procaine hydrochloride (PCH) from large unilamellar liposomes in the presence of simulated tear fluid was studied in vitro as a function of bilayer lipid content and tear protein composition. Reverse-phase evaporation vesicles were prepared from egg phosphatidylcholine, stearylamine or dicetyl phosphate, and cholesterol. The relationship between lipid composition and encapsulation efficiency, vesicle size, drug leakage upon storage at 4 degrees C, and the release of PCH-loaded liposomes was studied. The encapsulation efficiency was found to be dependent upon the lipid composition used in the liposome preparation. In particular, phosphatidylcholine vesicles containing cholesterol and/or charged lipids had a lower entrapment efficiency than liposomes prepared with phosphatidylcholine alone. However, the drug release rate was reduced significantly by inclusion of cholesterol and/or charged lipids in the liposomes. The release kinetics of the entrapped agent seemed to be a biphasic process and the drug-release in both simulated tear fluid (STF) and pH 7.4 phosphate buffered saline (PBS) solutions followed pseudo first-order kinetics in the early stage of the release profile. The drug-release appeared to be diffusion and/or partition controlled. Drug release from liposomes into STF, pH 7.4 PBS, and five different modified tear formulations was also evaluated. While serum-induced leakage is attributed to high-density lipoprotein-mediated destabilization, it was determined that lactoferrin might be the protein component in tear fluid that has the primary influence on the liposome-entrapped drug release rate. Five local anesthetics, benoxinate, proparacaine, procaine, tetracaine, and benzocaine were entrapped in liposomal vesicles by a reverse-phase evaporation (REV) technique. The release of these structurally similar topical anesthetics entrapped in positively charged liposomes (egg phosphatidylcholine, stearylamine, and cholesterol in a 7:2:1 molar ratio) was evaluated in a simulated tear fluid and pH 7.4 phosphate buffered saline solution. The liposomes appeared to be useful carriers for these drugs to retard their in vitro release in tear fluid and perhaps sustain or control their release in the eye for better therapeutic efficacy. An analysis of the release data demonstrated that for this series of drugs, drug partition coefficient has the largest effect on release rate, with molecular weight exhibiting a smaller effect. Release rate was found to decrease with increased lipophilicity or increased molecular weight.

  5. The Potential of Computational Fluid Dynamics Simulation on Serial Monitoring of Hemodynamic Change in Type B Aortic Dissection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yu, Simon C. H., E-mail: simonyu@cuhk.edu.hk; Liu, Wen; Wong, Randolph H. L.

    PurposeWe aimed to assess the potential of computational fluid dynamics simulation (CFD) in detecting changes in pressure and flow velocity in response to morphological changes in type B aortic dissection.Materials and MethodsPressure and velocity in four morphological models of type B aortic dissection before and after closure of the entry tear were calculated with CFD and analyzed for changes among the different scenarios. The control model (Model 1) was patient specific and built from the DICOM data of CTA, which bore one entry tear and three re-entry tears. Models 2–4 were modifications of Model 1, with two re-entry tears lessmore » in Model 2, one re-entry tear more in Model 3, and a larger entry tear in Model 4.ResultsThe pressure and velocity pertaining to each of the morphological models were unique. Changes in pressure and velocity findings were accountable by the changes in morphological features of the different models. There was no blood flow in the false lumen across the entry tear after its closure, the blood flow direction across the re-entry tears was reversed after closure of the entry tear.ConclusionCFD simulation is probably useful to detect hemodynamic changes in the true and false lumens of type B aortic dissection in response to morphological changes, it may potentially be developed into a non-invasive and patient-specific tool for serial monitoring of hemodynamic changes of type B aortic dissection before and after treatment.« less

  6. Realistic facial expression of virtual human based on color, sweat, and tears effects.

    PubMed

    Alkawaz, Mohammed Hazim; Basori, Ahmad Hoirul; Mohamad, Dzulkifli; Mohamed, Farhan

    2014-01-01

    Generating extreme appearances such as scared awaiting sweating while happy fit for tears (cry) and blushing (anger and happiness) is the key issue in achieving the high quality facial animation. The effects of sweat, tears, and colors are integrated into a single animation model to create realistic facial expressions of 3D avatar. The physical properties of muscles, emotions, or the fluid properties with sweating and tears initiators are incorporated. The action units (AUs) of facial action coding system are merged with autonomous AUs to create expressions including sadness, anger with blushing, happiness with blushing, and fear. Fluid effects such as sweat and tears are simulated using the particle system and smoothed-particle hydrodynamics (SPH) methods which are combined with facial animation technique to produce complex facial expressions. The effects of oxygenation of the facial skin color appearance are measured using the pulse oximeter system and the 3D skin analyzer. The result shows that virtual human facial expression is enhanced by mimicking actual sweating and tears simulations for all extreme expressions. The proposed method has contribution towards the development of facial animation industry and game as well as computer graphics.

  7. Realistic Facial Expression of Virtual Human Based on Color, Sweat, and Tears Effects

    PubMed Central

    Alkawaz, Mohammed Hazim; Basori, Ahmad Hoirul; Mohamad, Dzulkifli; Mohamed, Farhan

    2014-01-01

    Generating extreme appearances such as scared awaiting sweating while happy fit for tears (cry) and blushing (anger and happiness) is the key issue in achieving the high quality facial animation. The effects of sweat, tears, and colors are integrated into a single animation model to create realistic facial expressions of 3D avatar. The physical properties of muscles, emotions, or the fluid properties with sweating and tears initiators are incorporated. The action units (AUs) of facial action coding system are merged with autonomous AUs to create expressions including sadness, anger with blushing, happiness with blushing, and fear. Fluid effects such as sweat and tears are simulated using the particle system and smoothed-particle hydrodynamics (SPH) methods which are combined with facial animation technique to produce complex facial expressions. The effects of oxygenation of the facial skin color appearance are measured using the pulse oximeter system and the 3D skin analyzer. The result shows that virtual human facial expression is enhanced by mimicking actual sweating and tears simulations for all extreme expressions. The proposed method has contribution towards the development of facial animation industry and game as well as computer graphics. PMID:25136663

  8. Coupling Osmolarity Dynamics within Human Tear Film on an Eye-Shaped Domain

    NASA Astrophysics Data System (ADS)

    Li, Longfei; Braun, R. J.; Driscoll, T. A.; Henshaw, W. D.; Banks, J. W.; King-Smith, P. E.

    2013-11-01

    The concentration of ions in the tear film (osmolarity) is a key variable in understanding dry eye symptoms and disease. We derived a mathematical model that couples osmolarity (treated as a single solute) and fluid dynamics within the tear film on a 2D eye-shaped domain. The model concerns the physical effects of evaporation, surface tension, viscosity, ocular surface wettability, osmolarity, osmosis and tear fluid supply and drainage. We solved the governing system of coupled nonlinear PDEs using the Overture computational framework developed at LLNL, together with a new hybrid time stepping scheme (using variable step BDF and RKC) that was added to the framework. Results of our numerical simulations show good agreement with existing 1D models (for both tear film and osmolarity dynamics) and provide new insight about the osmolarity distribution over the ocular surface during the interblink.

  9. Computed tear film and osmolarity dynamics on an eye-shaped domain

    PubMed Central

    Li, Longfei; Braun, Richard J.; Driscoll, Tobin A.; Henshaw, William D.; Banks, Jeffrey W.; King-Smith, P. Ewen

    2016-01-01

    The concentration of ions, or osmolarity, in the tear film is a key variable in understanding dry eye symptoms and disease. In this manuscript, we derive a mathematical model that couples osmolarity (treated as a single solute) and fluid dynamics within the tear film on a 2D eye-shaped domain. The model includes the physical effects of evaporation, surface tension, viscosity, ocular surface wettability, osmolarity, osmosis and tear fluid supply and drainage. The governing system of coupled non-linear partial differential equations is solved using the Overture computational framework, together with a hybrid time-stepping scheme, using a variable step backward differentiation formula and a Runge–Kutta–Chebyshev method that were added to the framework. The results of our numerical simulations provide new insight into the osmolarity distribution over the ocular surface during the interblink. PMID:25883248

  10. Goldmann tonometry tear film error and partial correction with a shaped applanation surface.

    PubMed

    McCafferty, Sean J; Enikov, Eniko T; Schwiegerling, Jim; Ashley, Sean M

    2018-01-01

    The aim of the study was to quantify the isolated tear film adhesion error in a Goldmann applanation tonometer (GAT) prism and in a correcting applanation tonometry surface (CATS) prism. The separation force of a tonometer prism adhered by a tear film to a simulated cornea was measured to quantify an isolated tear film adhesion force. Acrylic hemispheres (7.8 mm radius) used as corneas were lathed over the apical 3.06 mm diameter to simulate full applanation contact with the prism surface for both GAT and CATS prisms. Tear film separation measurements were completed with both an artificial tear and fluorescein solutions as a fluid bridge. The applanation mire thicknesses were measured and correlated with the tear film separation measurements. Human cadaver eyes were used to validate simulated cornea tear film separation measurement differences between the GAT and CATS prisms. The CATS prism tear film adhesion error (2.74±0.21 mmHg) was significantly less than the GAT prism (4.57±0.18 mmHg, p <0.001). Tear film adhesion error was independent of applanation mire thickness ( R 2 =0.09, p =0.04). Fluorescein produces more tear film error than artificial tears (+0.51±0.04 mmHg; p <0.001). Cadaver eye validation indicated the CATS prism's tear film adhesion error (1.40±0.51 mmHg) was significantly less than that of the GAT prism (3.30±0.38 mmHg; p =0.002). Measured GAT tear film adhesion error is more than previously predicted. A CATS prism significantly reduced tear film adhesion error bŷ41%. Fluorescein solution increases the tear film adhesion compared to artificial tears, while mire thickness has a negligible effect.

  11. Finite Larmor radius effects on the (m = 2, n = 1) cylindrical tearing mode

    NASA Astrophysics Data System (ADS)

    Chen, Y.; Chowdhury, J.; Parker, S. E.; Wan, W.

    2015-04-01

    New field solvers are developed in the gyrokinetic code GEM [Chen and Parker, J. Comput. Phys. 220, 839 (2007)] to simulate low-n modes. A novel discretization is developed for the ion polarization term in the gyrokinetic vorticity equation. An eigenmode analysis with finite Larmor radius effects is developed to study the linear resistive tearing mode. The mode growth rate is shown to scale with resistivity as γ ˜ η1/3, the same as the semi-collisional regime in previous kinetic treatments [Drake and Lee, Phys. Fluids 20, 1341 (1977)]. Tearing mode simulations with gyrokinetic ions are verified with the eigenmode calculation.

  12. Phospholipid transfer protein is present in human tear fluid.

    PubMed

    Jauhiainen, Matti; Setälä, Niko L; Ehnholm, Christian; Metso, Jari; Tervo, Timo M T; Eriksson, Ove; Holopainen, Juha M

    2005-06-07

    The human tear fluid film consists of a superficial lipid layer, an aqueous middle layer, and a hydrated mucin layer located next to the corneal epithelium. The superficial lipid layer protects the eye from drying and is composed of polar and neutral lipids provided by the meibomian glands. Excess accumulation of lipids in the tear film may lead to drying of the corneal epithelium. In the circulation, phospholipid transfer protein (PLTP) and cholesteryl ester transfer protein (CETP) mediate lipid transfers. To gain insight into the formation of tear film, we investigated whether PLTP and CETP are present in human tear fluid. Tear fluid samples were collected with microcapillaries. The presence of PLTP and CETP was studied in tear fluid by Western blotting, and the PLTP concentration was determined by ELISA. The activities of the enzymes were determined by specific lipid transfer assays. Size-exclusion and heparin-affinity chromatography assessed the molecular form of PLTP. PLTP is present in tear fluid, whereas CETP is not. Quantitative assessment of PLTP by ELISA indicated that the PLTP concentration in tear fluid, 10.9 +/- 2.4 microg/mL, is about 2-fold higher than that in human plasma. PLTP-facilitated phospholipid transfer activity in tears, 15.1 +/- 1.8 micromol mL(-)(1) h(-)(1), was also significantly higher than that measured in plasma. Inactivation of PLTP by heat treatment (+58 degrees C, 60 min) or immunoinhibition abolished the phospholipid transfer activity in tear fluid. Size-exclusion chromatography of tear fluid indicated that PLTP eluted in a position corresponding to a size of 160-170 kDa. Tear fluid PLTP was quantitatively bound to Heparin-Sepharose and could be eluted as a single peak by 0.5 M NaCl. These data indicate that human tear fluid contains catalytically active PLTP protein, which resembles the active form of PLTP present in plasma. The results suggest that PLTP may play a role in the formation of the tear film by supporting phospholipid transfer.

  13. Towards Multiscale Interactions Between Tearing Modes and Microturbulence

    NASA Astrophysics Data System (ADS)

    Williams, Z. R.; Pueschel, M. J.; Terry, P. W.

    2017-10-01

    Work on the Madison Symmetric Torus Reversed-Field Pinch (RFP) has shown that large-scale tearing modes present in standard operation are highly detrimental to confinement. These tearing modes, even when reduced in improved confinement regimes of operation, significantly affect zonal flow activity and play a large role in setting microturbulent-induced transport levels. Previous gyrokinetic work has shown that a small but finite tearing fluctuation amplitude is necessary to produce transport values in agreement with experimental observation. This has previously been implemented via an ad-hoc, constant-in-time A∥ perturbation. This work details self-consistent modeling of tearing fluctuations in the RFP using the Gene code via the inclusion of a current gradient drive incorporated into the background distribution function. Tearing mode growth rates calculated from gyrokinetic simulations are benchmarked with results from fluid theory. Additionally, first results from multiscale Gene simulations describing tearing mode interactions with RFP microturbulence are presented. This work is supported by the U.S. Department of Energy, Grant No. DE-FG02-85ER-53121.

  14. Finite Larmor radius effects on the (m = 2, n = 1) cylindrical tearing mode

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Y.; Chowdhury, J.; Parker, S. E.

    2015-04-15

    New field solvers are developed in the gyrokinetic code GEM [Chen and Parker, J. Comput. Phys. 220, 839 (2007)] to simulate low-n modes. A novel discretization is developed for the ion polarization term in the gyrokinetic vorticity equation. An eigenmode analysis with finite Larmor radius effects is developed to study the linear resistive tearing mode. The mode growth rate is shown to scale with resistivity as γ ∼ η{sup 1∕3}, the same as the semi-collisional regime in previous kinetic treatments [Drake and Lee, Phys. Fluids 20, 1341 (1977)]. Tearing mode simulations with gyrokinetic ions are verified with the eigenmode calculation.

  15. Tear film dynamics with evaporation, wetting, and time-dependent flux boundary condition on an eye-shaped domain

    PubMed Central

    Li, Longfei; Braun, R. J.; Maki, K. L.; Henshaw, W. D.; King-Smith, P. E.

    2014-01-01

    We study tear film dynamics with evaporation on a wettable eye-shaped ocular surface using a lubrication model. The mathematical model has a time-dependent flux boundary condition that models the cycles of tear fluid supply and drainage; it mimics blinks on a stationary eye-shaped domain. We generate computational grids and solve the nonlinear governing equations using the OVERTURE computational framework. In vivo experimental results using fluorescent imaging are used to visualize the influx and redistribution of tears for an open eye. Results from the numerical simulations are compared with the experiment. The model captures the flow around the meniscus and other dynamic features of human tear film observed in vivo. PMID:24926191

  16. Dry eye symptoms are increased in mice deficient in phospholipid transfer protein (PLTP).

    PubMed

    Setälä, Niko L; Metso, Jari; Jauhiainen, Matti; Sajantila, Antti; Holopainen, Juha M

    2011-05-01

    In the tear fluid the outermost part facing the tear-air interface is composed of lipids preventing evaporation of the tears. Phospholipid transfer protein (PLTP) mediates phospholipid transfer processes between serum lipoproteins and is also a normal component of human tears. To study whether PLTP plays any functional role in tear fluid we investigated PLTP-deficient mice, applying functional and morphologic analyses under normal housing and experimentally induced dry eye conditions. Aqueous tear fluid production, corneal epithelial morphology, barrier function, and occludin expression were assessed. In mice with a full deficiency of functional PLTP enhanced corneal epithelial damage, increased corneal permeability to carboxyfluorescein, and decreased corneal epithelial occludin expression were shown. These pathologic signs were worsened by experimentally induced dry eye both in wild-type and PLTP knock-out mice. Deficiency in the production of tear PLTP in mice is accompanied by corneal epithelial damage, a feature that is typical in human dry eye syndrome (DES). To complement animal experiments we collected tear fluid from human dry eye patients as well as healthy control subjects. Increased tear fluid PLTP activity was observed among DES patients. In conclusion, the presence of PLTP in tear fluid appears to be essential for maintaining a healthy and functional ocular surface. Increased PLTP activity in human tear fluid in DES patients suggests an ocular surface protective role for this lipid transfer protein. Copyright © 2011 American Society for Investigative Pathology. Published by Elsevier Inc. All rights reserved.

  17. Effects of DA-6034 on aqueous tear fluid secretion and conjunctival goblet cell proliferation.

    PubMed

    Choi, Seul Min; Lee, Yeong Geon; Seo, Mi Jung; Kang, Kyung Koo; Ahn, Byoung Ok; Yoo, Moohi

    2009-06-01

    This study was conducted to evaluate the effect of DA-6034, a potent secretagogue, on aqueous tear fluid secretion and its quality in normal rabbit. We also evaluated, in animal models of experimentally induced dry eye disease, its effectiveness over time to stimulate aqueous tear production by ocular ferning test and goblet cell proliferation. Aqueous tear production, total protein levels, and glycoprotein levels in normal rabbits were evaluated after topical application of DA-6034 (0.3, 1, and 3%). Moreover, time course aqueous tear volume measurement and ocular ferning test in tear fluid were performed in dry eyes of rabbits that had been given 1% atropine sulfate, topically. Altogether, tear fluid production and conjunctival goblet cell numbers were measured in dry eyes of mice that had been given topical scopolamine. Topical application of DA-6034 (0.3, 1, and 3%) significantly increased (P < 0.05) aqueous tear production in a concentration-dependent manner in normal rabbits. There was no change in total protein levels while glycoprotein levels were significantly increased (P < 0.05) at 3% DA-6034. The increase in aqueous tear fluid was significant (P < 0.05) and lasted for 2 h post-instillation in dry eyes of rabbits that had been given 1% atropine sulfate; 10-day repeated instillation of the drug in this model resulted in large and homogeneous fern-like tear patterns. In a mouse model, DA-6034 given as a 3% eyedrop solution significantly increased (P < 0.05) tear fluid production and conjunctival goblet cell number. These results suggest that DA-6034 accelerates not only tear secretion but also mucin production and may be a potential therapeutic agent for the treatment of dry eye disease.

  18. Human Tear Fluid Reduces Culturability of Contact Lens Associated Pseudomonas aeruginosa Biofilms but Induces Expression of the Virulence Associated Type III Secretion System

    PubMed Central

    Wu, Yvonne T.; Tam, Connie; Zhu, Lucia S.; Evans, David J.; Fleiszig, Suzanne M. J.

    2017-01-01

    Purpose The type III secretion system (T3SS) is a significant virulence determinant for Pseudomonas aeruginosa. Using a rodent model, we found that contact lens (CL)-related corneal infections were associated with lens surface biofilms. Here, we studied the impact of human tear fluid on CL-associated biofilm growth and T3SS expression. Methods P. aeruginosa biofilms were formed on contact lenses for up to 7 days with or without human tear fluid, then exposed to tear fluid for 5 or 24 h. Biofilms were imaged using confocal microscopy. Bacterial culturability was quantified by viable counts, and T3SS gene expression measured by RT-qPCR. Controls included trypticase soy broth, PBS and planktonic bacteria. Results With or without tear fluid, biofilms grew to ~108 cfu viable bacteria by 24 h. Exposing biofilms to tear fluid after they had formed without it on lenses reduced bacterial culturability ~180-fold (p<.001). CL growth increased T3SS gene expression versus planktonic bacteria [5.46 ± 0.24-fold for T3SS transcriptional activitor exsA (p=.02), and 3.76 ± 0.36-fold for T3SS effector toxin exoS (p=.01)]. Tear fluid further enhanced exsA and exoS expression in CL-grown biofilms, but not planktonic bacteria, by 2.09 ± 0.38-fold (p = 0.04) and 1.89 ± 0.26-fold (p<.001), respectively. Conclusions Considering the pivitol role of the T3SS in P. aeruginosa infections, its induction in CL-grown P. aeruginosa biofilms by tear fluid might contribute to the pathogenesis of CL-related P. aeruginosa keratitis. PMID:27670247

  19. Modeling ECCD/MHD coupling using NIMROD, GENRAY, and the Integrated Plasma Simulator

    NASA Astrophysics Data System (ADS)

    Jenkins, Thomas G.; Schnack, D. D.; Sovinec, C. R.; Hegna, C. C.; Callen, J. D.; Ebrahimi, F.; Kruger, S. E.; Carlsson, J.; Held, E. D.; Ji, J.-Y.; Harvey, R. W.; Smirnov, A. P.; Elwasif, W. R.

    2009-11-01

    We summarize ongoing theoretical/numerical work relevant to the development of a self--consistent framework for the inclusion of RF effects in fluid simulations; specifically, we consider the stabilization of resistive tearing modes in tokamak geometry by electron cyclotron current drive. In the fluid equations, ad hoc models for the RF--induced currents have previously been shown to shrink or altogether suppress the nonlinearly saturated magnetic islands generated by tearing modes; progress toward a self--consistent model is reported. The interfacing of the NIMROD [1] code with the GENRAY/CQL3D [2] codes (which calculate RF propagation and energy/momentum deposition) via the Integrated Plasma Simulator (IPS) framework [3] is explained, RF-induced rational surface motion and the equilibration of RF--induced currents over plasma flux surfaces are investigated, and the efficient reduction of saturated island widths through time modulation and spatial localization of the ECCD is explored. [1] Sovinec et al., JCP 195, 355 (2004) [2]www.compxco.com [3] Both the IPS development and the research presented here are part of the SWIM project. Funded by U.S. DoE.

  20. Modeling of RF/MHD coupling using NIMROD, GENRAY, and the Integrated Plasma Simulator

    NASA Astrophysics Data System (ADS)

    Jenkins, Thomas; Schnack, D. D.; Sovinec, C. R.; Hegna, C. C.; Callen, J. D.; Ebrahimi, F.; Kruger, S. E.; Carlsson, J.; Held, E. D.; Ji, J.-Y.; Harvey, R. W.; Smirnov, A. P.

    2009-05-01

    We summarize ongoing theoretical/numerical work relevant to the development of a self--consistent framework for the inclusion of RF effects in fluid simulations; specifically considering resistive tearing mode stabilization in tokamak (DIII--D--like) geometry via ECCD. Relatively simple (though non--self--consistent) models for the RF--induced currents are incorporated into the fluid equations, markedly reducing the width of the nonlinearly saturated magnetic islands generated by tearing modes. We report our progress toward the self--consistent modeling of these RF--induced currents. The initial interfacing of the NIMROD* code with the GENRAY/CQL3D** codes (calculating RF propagation and energy/momentum deposition) via the Integrated Plasma Simulator (IPS) framework*** is explained, equilibration of RF--induced currents over the plasma flux surfaces is investigated, and studies exploring the efficient reduction of saturated island widths through time modulation and spatial localization of the ECCD are presented. *[Sovinec et al., JCP 195, 355 (2004)] **[www.compxco.com] ***[This research and the IPS development are both part of the SWIM project. Funded by U.S. DoE.

  1. Effectiveness of surface enhanced Raman spectroscopy of tear fluid with soft substrate for point-of-care therapeutic drug monitoring

    NASA Astrophysics Data System (ADS)

    Yamada, K.; Endo, T.; Imai, H.; Kido, M.; Jeong, H.; Ohno, Y.

    2016-03-01

    We have developed the point-of-care therapeutic drug monitoring kit based on Raman Spectroscopy of tear fluid. In this study, we were examined a soft substrate for an optimal lattice based on nanoimprint lithography using cyclo-olefin polymer to improve the sensitivity for measuring drug concentration in tear fluid. This is photonics crystal which is one of the nano-photonics based device was fabricated. Target is Sodium Phenobarbital which is an anticonvulsant agent. We show the effectiveness of Surface Enhanced Raman Spectroscopy of tear fluid with soft substrate for point-of-care therapeutic drug monitoring.

  2. Interferometric characterization of tear film dynamics

    NASA Astrophysics Data System (ADS)

    Primeau, Brian Christopher

    The anterior refracting surface of the eye is the thin tear film that forms on the surface of the cornea. When a contact lens is on worn, the tear film covers the contact lens as it would a bare cornea, and is affected by the contact lens material properties. Tear film irregularity can cause both discomfort and vision quality degradation. Under normal conditions, the tear film is less than 10 microns thick and the thickness and topography change in the time between blinks. In order to both better understand the tear film, and to characterize how contact lenses affect tear film behavior, two interferometers were designed and built to separately measure tear film behavior in vitro and in vivo. An in vitro method of characterizing dynamic fluid layers applied to contact lenses mounted on mechanical substrates has been developed using a phase-shifting Twyman-Green interferometer. This interferometer continuously measures light reflected from the surface of the fluid layer, allowing precision analysis of the dynamic fluid layer. Movies showing this fluid layer behavior can be generated. The fluid behavior on the contact lens surface is measured, allowing quantitative analysis beyond what typical contact angle or visual inspection methods provide. The in vivo interferometer is a similar system, with additional modules included to provide capability for human testing. This tear film measurement allows analysis beyond capabilities of typical fluorescein visual inspection or videokeratometry and provides better sensitivity and resolution than shearing interferometry methods.

  3. Assay of mucins in human tear fluid.

    PubMed

    Spurr-Michaud, Sandra; Argüeso, Pablo; Gipson, Ilene

    2007-05-01

    Mucin genes, both secreted (MUC2, MUC5AC, MUC5B, MUC7) and membrane associated (MUC1, MUC4, MUC16), have been reported to be expressed by ocular surface epithelia. The purpose of this study was to comprehensively assay the mucin content of human tear fluid using multiple antibodies for each mucin and to develop a sensitive, semi-quantitative method for the assay of mucins in tears. Tear washes were obtained by instillation of saline onto the ocular surface, followed by collection from the inferior fornix. Tear proteins were separated in 1% agarose gels, transferred to nitrocellulose membrane by vacuum blotting and probed with multiple antibodies recognizing MUC1, MUC2, MUC4, MUC5AC, MUC5B, MUC7 and MUC16. Binding was detected using chemiluminescence, and quantity was determined by densitometry. Serial dilutions of pooled tears from normal individuals were assayed to determine the linear range of detectability. MUC1, MUC4, MUC16, MUC5AC and low levels of MUC2 were consistently detected in human tear fluid, while MUC5B and MUC7 were not. Use of several antibodies recognizing different epitopes on the same mucin confirmed these findings. The antibodies to mucins bound to serial dilutions of tears in a linear fashion (r2 > 0.9), indicating the feasibility of semi-quantitation. MUC5AC in tear fluid had an increased electrophoretic mobility compared to MUC5AC isolated from conjunctival tissue. This study provides clear evidence that the mucin component of tears is a mixture of secreted and shed membrane-associated mucins, and for the first time demonstrates MUC16 in tear fluid. Immunoblots of tears using agarose gel electrophoresis and chemiluminescence detection provide a semi-quantitative assay for mucin protein that will be useful for comparisons with tears from diseased eyes or after pharmacological intervention.

  4. Assay of Mucins in Human Tear Fluid

    PubMed Central

    Spurr-Michaud, Sandra; Argüeso, Pablo; Gipson, Ilene

    2007-01-01

    Mucin genes, both secreted (MUC2, MUC5AC, MUC5B, MUC7) and membrane associated (MUC1, MUC4, MUC16), have been reported to be expressed by ocular surface epithelia. The purpose of this study was to comprehensively assay the mucin content of human tear fluid using multiple antibodies for each mucin and to develop a sensitive, semi-quantitative method for the assay of mucins in tears. Tear washes were obtained by instillation of saline onto the ocular surface, followed by collection from the inferior fornix. Tear proteins were separated in 1% agarose gels, transferred to nitrocellulose membrane by vacuum blotting and probed with multiple antibodies recognizing MUC1, MUC2, MUC4, MUC5AC, MUC5B, MUC7 and MUC16. Binding was detected using chemiluminescence, and quantity was determined by densitometry. Serial dilutions of pooled tears from normal individuals were assayed to determine the linear range of detectability. MUC1, MUC4, MUC16, MUC5AC and low levels of MUC2 were consistently detected in human tear fluid, while MUC5B and MUC7 were not. Use of several antibodies recognizing different epitopes on the same mucin confirmed these findings. The antibodies to mucins bound to serial dilutions of tears in a linear fashion (r2 >0.9), indicating the feasibility of semi-quantitation. MUC5AC in tear fluid had an increased electrophoretic mobility compared to MUC5AC isolated from conjunctival tissue. This study provides clear evidence that the mucin component of tears is a mixture of secreted and shed membrane-associated mucins, and for the first time demonstrates MUC16 in tear fluid. Immunoblots of tears using agarose gel electrophoresis and chemiluminescence detection provide a semi-quantitative assay for mucin protein that will be useful for comparisons with tears from diseased eyes or after pharmacological intervention. PMID:17399701

  5. ECCD-induced tearing mode stabilization in coupled IPS/NIMROD/GENRAY HPC simulations

    NASA Astrophysics Data System (ADS)

    Jenkins, Thomas; Kruger, S. E.; Held, E. D.; Harvey, R. W.; Elwasif, W. R.

    2012-03-01

    We summarize ongoing developments toward an integrated, predictive model for determining optimal ECCD-based NTM stabilization strategies in ITER. We demonstrate the capability of the SWIM Project's Integrated Plasma Simulator (IPS) framework to choreograph multiple executions of, and data exchanges between, physics codes modeling various spatiotemporal scales of this coupled RF/MHD problem on several thousand HPC processors. As NIMROD evolves fluid equations to model bulk plasma behavior, self-consistent propagation/deposition of RF power in the ensuing plasma profiles is calculated by GENRAY. Data from both codes is then processed by computational geometry packages to construct the RF-induced quasilinear diffusion tensor; moments of this tensor (entering as additional terms in NIMROD's fluid equations due to the disparity in RF/MHD spatiotemporal scales) influence the dynamics of current, momentum, and energy evolution as well as the MHD closures. Initial results are shown to correctly capture the physics of magnetic island stabilization; we also discuss the development of a numerical plasma control system for active feedback stabilization of tearing modes.

  6. Mucosal fluid glycoprotein DMBT1 suppresses twitching motility and virulence of the opportunistic pathogen Pseudomonas aeruginosa

    PubMed Central

    Evans, David J.; Fleiszig, Suzanne M. J.

    2017-01-01

    It is generally thought that mucosal fluids protect underlying epithelial surfaces against opportunistic infection via their antimicrobial activity. However, our published data show that human tear fluid can protect against the major opportunistic pathogen Pseudomonas aeruginosa independently of bacteriostatic activity. Here, we explored the mechanisms for tear protection, focusing on impacts of tear fluid on bacterial virulence factor expression. Results showed that tear fluid suppressed twitching motility, a type of surface-associated movement conferred by pili. Previously, we showed that twitching is critical for P. aeruginosa traversal of corneal epithelia, exit from epithelial cells after internalization, and corneal virulence. Inhibition of twitching by tear fluid was dose-dependent with dilutions to 6.25% retaining activity. Purified lactoferrin, lysozyme, and contrived tears containing these, and many other, tear components lacked the activity. Systematic protein fractionation, mass spectrometry, and immunoprecipitation identified the glycoprotein DMBT1 (Deleted in Malignant Brain Tumors 1) in tear fluid as required. DMBT1 purified from human saliva also inhibited twitching, as well as P. aeruginosa traversal of human corneal epithelial cells in vitro, and reduced disease pathology in a murine model of corneal infection. DMBT1 did not affect PilA expression, nor bacterial intracellular cyclicAMP levels, and suppressed twitching motility of P. aeruginosa chemotaxis mutants (chpB, pilK), and an adenylate cyclase mutant (cyaB). However, dot-immunoblot assays showed purified DMBT1 binding of pili extracted from PAO1 suggesting that twitching inhibition may involve a direct interaction with pili. The latter could affect extension or retraction of pili, their interactions with biotic or abiotic surfaces, or cause their aggregation. Together, the data suggest that DMBT1 inhibition of twitching motility contributes to the mechanisms by which mucosal fluids protect against P. aeruginosa infection. This study also advances our understanding of how mucosal fluids protect against infection, and suggests directions for novel biocompatible strategies to protect our surface epithelia against a major opportunistic pathogen. PMID:28489917

  7. Solute Dynamics and Imaging in the Tear Film on an Eye-shaped Domain

    NASA Astrophysics Data System (ADS)

    Braun, R. J.; Li, Longfei; Henshaw, William; Driscoll, Tobin; King-Smith, P. E.

    2015-11-01

    The concentration of ions in the tear film (osmolarity) is a key variable in understanding dry eye symptoms and disease, yet its global distribution is not available; direct measurements are restricted to a region near the temporal canthus. It has been suggested that imaging methods that use solutes such as fluorescein can be used as a proxy for estimating the osmolarity. The concentration of fluorescein is not measured directly either but the intensity as a function of concentration and thickness of the film is well established. We derived a mathematical model that couples multiple solutes and fluid dynamics within the tear film on a 2D eye-shaped domain. The model includes the physical effects of evaporation, surface tension, viscosity, ocular surface wettability, osmolarity, osmosis, fluorescence and tear fluid supply and drainage. We solved the governing system of coupled nonlinear PDEs using the Overture computational framework developed at LLNL, together with a hybrid time stepping scheme (using variable step BDF and RKC). Results of our numerical simulations provide new insight about the osmolarity distribution and its connection with images obtained in vivo over the whole ocular surface and in local regions of tear thinning due to evaporation and other effects. This work was supported in part by NSF grants 1022706 and 1412085, and NIH grant 1R01EY021794.

  8. Effect of viscosity on tear drainage and ocular residence time.

    PubMed

    Zhu, Heng; Chauhan, Anuj

    2008-08-01

    An increase in residence time of dry eye medications including artificial tears will likely enhance therapeutic benefits. The drainage rates and the residence time of eye drops depend on the viscosity of the instilled fluids. However, a quantitative understanding of the dependence of drainage rates and the residence time on viscosity is lacking. The current study aims to develop a mathematical model for the drainage of Newtonian fluids and also for power-law non-Newtonian fluids of different viscosities. This study is an extension of our previous study on the mathematical model of tear drainage. The tear drainage model is modified to describe the drainage of Newtonian fluids with viscosities higher than the tear viscosity and power-law non-Newtonian fluids with rheological parameters obtained from fitting experimental data in literature. The drainage rate through canaliculi was derived from the modified drainage model and was incorporated into a tear mass balance to calculate the transients of total solute quantity in ocular fluids and the bioavailability of instilled drugs. For Newtonian fluids, increasing the viscosity does not affect the drainage rate unless the viscosity exceeds a critical value of about 4.4 cp. The viscosity has a maximum impact on drainage rate around a value of about 100 cp. The trends are similar for shear thinning power law fluids. The transients of total solute quantity, and the residence time agrees at least qualitatively with experimental studies. A mathematical model has been developed for the drainage of Newtonian fluids and power-law fluids through canaliculi. The model can quantitatively explain different experimental observations on the effect of viscosity on the residence of instilled fluids on the ocular surface. The current study is helpful for understanding the mechanism of fluid drainage from the ocular surface and for improving the design of dry eye treatments.

  9. Elimination of Hot Tears in Steel Castings by Means of Solidification Pattern Optimization

    NASA Astrophysics Data System (ADS)

    Kotas, Petr; Tutum, Cem Celal; Thorborg, Jesper; Hattel, Jesper Henri

    2012-06-01

    A methodology of how to exploit the Niyama criterion for the elimination of various defects such as centerline porosity, macrosegregation, and hot tearing in steel castings is presented. The tendency of forming centerline porosity is governed by the temperature distribution close to the end of the solidification interval, specifically by thermal gradients and cooling rates. The physics behind macrosegregation and hot tears indicate that these two defects also are dependent heavily on thermal gradients and pressure drop in the mushy zone. The objective of this work is to show that by optimizing the solidification pattern, i.e., establishing directional and progressive solidification with the help of the Niyama criterion, macrosegregation and hot tearing issues can be both minimized or eliminated entirely. An original casting layout was simulated using a transient three-dimensional (3-D) thermal fluid model incorporated in a commercial simulation software package to determine potential flaws and inadequacies. Based on the initial casting process assessment, multiobjective optimization of the solidification pattern of the considered steel part followed. That is, the multiobjective optimization problem of choosing the proper riser and chill designs has been investigated using genetic algorithms while simultaneously considering their impact on centerline porosity, the macrosegregation pattern, and primarily on hot tear formation.

  10. Isotretinoin in lacrimal gland fluid and tears.

    PubMed

    Rismondo, V; Ubels, J L

    1987-03-01

    Isotretinoin (13-cis-retinoic acid) is used in the treatment of severe cystic acne. Adverse ocular reactions, including blepharoconjunctivitis and dry eye symptoms, are frequent side effects of this drug. Our previous observation that retinol is present in tears and lacrimal gland fluid suggests that isotretinoin may also be secreted by the lacrimal gland. Rabbits were treated with isotretinoin, and lacrimal gland fluid was collected from the cannulated lacrimal gland duct. Tears were collected from patients who were being treated with isotretinoin. Lacrimal gland fluid and tears were analyzed by reverse-phase high-pressure liquid chromatography and a peak eluted from each sample, which was identified as isotretinoin. We conclude that the lacrimal gland is able to secrete isotretinoin in addition to retinol and that, in animals and patients treated systemically with isotretinoin, the ocular surface is exposed to the drug via the tear film.

  11. Investigation of Tear Biomarkers as an Indicator of Human Health

    NASA Technical Reports Server (NTRS)

    Morton, Stephen; Tucker, Bethany; Crucian, Brian; Steinberg, Susan; Hagan, Suzanne

    2017-01-01

    Scientific literature suggests that tear biomarkers can be used as a guide towards clinical diagnosis of human health (Hagan et al., 2016). This study will investigate whether tear biomarkers represents a research and clinical opportunity to assess human health prior to, during, and after exposure to the spaceflight environment. The focus of this study is to compare biomarkers previously identified as potentially relevant to both ocular and brain health against unique physiological outcomes of exposure to the space flight environment. Study subjects suffering from terrestrial conditions thought to be similar to Spaceflight Associated Neuro-ocular Syndrome (SANS: formerly VIIP), e.g. patients with idiopathic intracranial hypertension (IIH) and optic neuritis may be relevant to conditions associated with spaceflight. This study will review methodologies, tear biomarkers related to state of ocular and brain health, the strengths and weakness of using tear fluid biomarkers versus other body fluid samples, and will survey current tear fluid biomarker knowledge in research and clinical practice. A strength of using tear biomarkers is that sampling is non-invasive and used as a guide in understanding pathologies, including ocular and systemic inflammatory conditions (Cocho et al., 2016)., Salvisberg et al., 2014). Moreover, tear biomarkers may reflect diseases affecting the central nervous system (CNS) (Salvisberg et al., 2014). For example, in multiple sclerosis (MS), the concordance rate between tear biomarkers versus cerebrospinal fluid (CSF) is approximately 83%, indicating that, in the majority of cases, tears are at least as effective as CSF in potentially identifying novel MS biomarkers (Devos et al., 2001).

  12. ECCD-induced tearing mode stabilization in coupled IPS/NIMROD/GENRAY HPC simulations

    NASA Astrophysics Data System (ADS)

    Jenkins, Thomas; Kruger, S. E.; Held, E. D.; Harvey, R. W.; Elwasif, W. R.; Schnack, D. D.; SWIM Project Team

    2011-10-01

    We present developments toward an integrated, predictive model for determining optimal ECCD-based NTM stabilization strategies in ITER. We demonstrate the capability of the SWIM Project's Integrated Plasma Simulator (IPS) framework to choreograph multiple executions of, and data exchanges between, physics codes modeling various spatiotemporal scales of this coupled RF/MHD problem on several thousand HPC processors. As NIMROD evolves fluid equations to model bulk plasma behavior, self-consistent propagation/deposition of RF power in the ensuing plasma profiles is calculated by GENRAY. A third code (QLCALC) then interfaces with computational geometry packages to construct the RF-induced quasilinear diffusion tensor from NIMROD/GENRAY data, and the moments of this tensor (entering as additional terms in NIMROD's fluid equations due to the disparity in RF/MHD spatiotemporal scales) influence the dynamics of current, momentum, and energy evolution. Initial results are shown to correctly capture the physics of magnetic island stabilization [Jenkins et al., PoP 17, 012502 (2010)]; we also discuss the development of a numerical plasma control system for active feedback stabilization of tearing modes. Funded by USDoE SciDAC.

  13. Levels of lipocalin-2 in crevicular fluid and tear fluid in chronic periodontitis and obesity subjects.

    PubMed

    Pradeep, Avani Raju; Nagpal, Kanika; Karvekar, Shruti; Patnaik, Kaushik

    2016-11-01

    Lipocalin-2, a 25 kDa secretory glycoprotein, was first found in the neutrophilic granules of humans and in mouse kidney cells. It has been shown to have an important role in inflammation. The aim of this study was to determine the levels of lipocalin-2 in gingival crevicular fluid and tear fluid in patients with obesity and chronic periodontitis. A total of 40 subjects in the age group 25-40 years were divided into four groups based on probing depth, gingival index, clinical attachment level, body mass index, and radiographic evidence of bone loss. The groups were: nonobese healthy group; obese healthy group; nonobese chronic periodontitis group; obese chronic periodontitis group Gingival crevicular fluid and tear fluid samples were collected on the subsequent day. There was an increase in lipocalin-2 levels from group 1 to group 4 (with the nonobese healthy group showing the least levels and obese chronic periodontitis group showing the highest levels) in both gingival crevicular fluid and tear fluid. Lipocalin-2 may be an important inflammatory marker that may help link obesity and chronic periodontitis. © 2015 Wiley Publishing Asia Pty Ltd.

  14. The Effect of Ambient Ozone on Unsaturated Tear Film Wax Esters.

    PubMed

    Paananen, Riku O; Rantamäki, Antti H; Parshintsev, Jevgeni; Holopainen, Juha M

    2015-12-01

    Tear film lipid layer (TFLL) is constantly exposed to reactive ozone in the surrounding air, which may have detrimental effects on ocular health. Behenyl oleate (BO), a representative tear film wax ester, was used to study the reaction with ozone at the air-water interface. Time-dependent changes in mean molecular area of BO monolayers were measured at different ozone concentrations and surface pressures. In addition, the effect of ascorbic acid on the reaction rate was determined. Reaction was followed using thin-layer chromatography and reaction products were identified using liquid chromatography-electrospray ionization mass spectrometry (LC-MS). Tear fluid samples from healthy subjects were analyzed with LC-MS for any ozonolysis reaction products. Behenyl oleate was found to undergo rapid ozonolysis at the air-water interface at normal indoor ozone concentrations. The reaction was observed as an initial expansion followed by a contraction of the film area. Ascorbic acid was found to decrease the rate of ozonolysis. Main reaction products were identified as behenyl 9-oxononanoate and behenyl 8-(5-octyl-1,2,4-trioxolan-3-yl)octanoate. Similar ozonolysis products were not detected in the tear fluid samples. At the air-water interface, unsaturated wax esters react readily with ozone in ambient air. However, no signs of ozonolysis products were found in the tear fluid. This is most likely due to the antioxidant systems present in tear fluid. Last, the results show that ozonolysis needs to be controlled in future surface chemistry studies on tear film lipids.

  15. Simulation of magnetic island dynamics under resonant magnetic perturbation with the TEAR code and validation of the results on T-10 tokamak data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ivanov, N. V.; Kakurin, A. M.

    2014-10-15

    Simulation of the magnetic island evolution under Resonant Magnetic Perturbation (RMP) in rotating T-10 tokamak plasma is presented with intent of TEAR code experimental validation. In the T-10 experiment chosen for simulation, the RMP consists of a stationary error field, a magnetic field of the eddy current in the resistive vacuum vessel and magnetic field of the externally applied controlled halo current in the plasma scrape-off layer (SOL). The halo-current loop consists of a rail limiter, plasma SOL, vacuum vessel, and external part of the circuit. Effects of plasma resistivity, viscosity, and RMP are taken into account in the TEARmore » code based on the two-fluid MHD approximation. Radial distribution of the magnetic flux perturbation is calculated with account of the externally applied RMP. A good agreement is obtained between the simulation results and experimental data for the cases of preprogrammed and feedback-controlled halo current in the plasma SOL.« less

  16. Specific IgE in tear fluid and features of allergic conjunctivitis.

    PubMed

    Mimura, Tatsuya; Yamagami, Satoru; Kamei, Yuko; Goto, Mari; Matsubara, Masao

    2013-09-01

    The level of specific class E immunoglobulins (IgE) in tear fluid is a useful diagnostic indicator for allergic conjunctivitis, but it is still unclear whether the measurement of tear fluid IgE is helpful for assessing the severity of allergic conjunctivitis. In this study, we evaluated the relation between tear fluid levels of specific IgE and features of allergic conjunctivitis. A prospective, nonrandomized, cross-sectional study was conducted in patients with allergic conjunctivitis (n = 55, allergic group) and age- and sex-matched healthy control subjects (n = 50, control group). Levels of specific IgE for cedar pollen, cat epithelium/dander and Dermatophagoides pteronyssinus were measured in tear fluid with the Immfast Check J1®. A severity score (0, 1, 2 or 3) was assigned for various changes of the palpebral and bulbar conjunctiva, as well as for limbal and corneal lesions. The levels of specific IgE for both cedar pollen, and D. pteronyssinus were significantly higher in the allergic group compared with the control group (p < 0.0001), while the level of specific IgE for cat epithelium/dander showed no significant difference between the two groups (p = 0.0777). When IgE levels were divided into four classes, the classes for both D. Pteronyssinus and cat epithelium/dander IgE were correlated with four features of allergic conjunctivitis. On the other hand, no correlation was found between the class of cedar pollen IgE and any of the features of allergic conjunctivitis. This study demonstrated that measurement of specific IgE in tear fluid may be useful for determining the severity of allergic conjunctivitis induced by indoor allergens. Although measurement of IgE in tear fluid is only a supplemental tool for evaluating the clinical activity of allergic conjunctivitis, the test can be useful for detecting specific IgE antibodies responsible for this condition.

  17. Unraveling the molecular repertoire of tears as a source of biomarkers: beyond ocular diseases.

    PubMed

    Pieragostino, Damiana; D'Alessandro, Michele; di Ioia, Maria; Di Ilio, Carmine; Sacchetta, Paolo; Del Boccio, Piero

    2015-02-01

    Proteomics and metabolomics investigations of body fluids present several challenges for biomarker discovery of several diseases. The search for biomarkers is actually conducted in different body fluids, even if the ideal biomarker can be found in an easily accessible biological fluid, because, if validated, the biomarker could be sought in the healthy population. In this regard, tears could be considered an optimum material obtained by noninvasive procedures. In the past years, the scientific community has become more interested in the study of tears for the research of new biomarkers not only for ocular diseases. In this review, we provide a discussion on the current state of biomarkers research in tears and their relevance for clinical practice, and report the main results of clinical proteomics studies on systemic and eye diseases. We summarize the main methods for tear samples analyses and report recent advances in "omics" platforms for tears investigations. Moreover, we want to take stock of the emerging field of metabolomics and lipidomics as a new and integrated approach to study protein-metabolites interplay for biomarkers research, where tears represent a still unexplored and attractive field. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. First-order finite-Larmor-radius fluid modeling of tearing and relaxation in a plasma pincha)

    NASA Astrophysics Data System (ADS)

    King, J. R.; Sovinec, C. R.; Mirnov, V. V.

    2012-05-01

    Drift and Hall effects on magnetic tearing, island evolution, and relaxation in pinch configurations are investigated using a non-reduced first-order finite-Larmor-radius (FLR) fluid model with the nonideal magnetohydrodynamics (MHD) with rotation, open discussion (NIMROD) code [C.R. Sovinec and J. R. King, J. Comput. Phys. 229, 5803 (2010)]. An unexpected result with a uniform pressure profile is a drift effect that reduces the growth rate when the ion sound gyroradius (ρs) is smaller than the tearing-layer width. This drift is present only with warm-ion FLR modeling, and analytics show that it arises from ∇B and poloidal curvature represented in the Braginskii gyroviscous stress. Nonlinear single-helicity computations with experimentally relevant ρs values show that the warm-ion gyroviscous effects reduce saturated-island widths. Computations with multiple nonlinearly interacting tearing fluctuations find that m = 1 core-resonant-fluctuation amplitudes are reduced by a factor of two relative to single-fluid modeling by the warm-ion effects. These reduced core-resonant-fluctuation amplitudes compare favorably to edge coil measurements in the Madison Symmetric Torus (MST) reversed-field pinch [R. N. Dexter et al., Fusion Technol. 19, 131 (1991)]. The computations demonstrate that fluctuations induce both MHD- and Hall-dynamo emfs during relaxation events. The presence of a Hall-dynamo emf implies a fluctuation-induced Maxwell stress, and the simulation results show net transport of parallel momentum. The computed magnitude of force densities from the Maxwell and competing Reynolds stresses, and changes in the parallel flow profile, are qualitatively and semi-quantitatively similar to measurements during relaxation in MST.

  19. First-order finite-Larmor-radius fluid modeling of tearing and relaxation in a plasma pinch

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    King, J. R.; Tech-X Corporation, 5621 Arapahoe Ave., Suite A Boulder, Colorado 80303; Sovinec, C. R.

    Drift and Hall effects on magnetic tearing, island evolution, and relaxation in pinch configurations are investigated using a non-reduced first-order finite-Larmor-radius (FLR) fluid model with the nonideal magnetohydrodynamics (MHD) with rotation, open discussion (NIMROD) code [C.R. Sovinec and J. R. King, J. Comput. Phys. 229, 5803 (2010)]. An unexpected result with a uniform pressure profile is a drift effect that reduces the growth rate when the ion sound gyroradius ({rho}{sub s}) is smaller than the tearing-layer width. This drift is present only with warm-ion FLR modeling, and analytics show that it arises from {nabla}B and poloidal curvature represented in themore » Braginskii gyroviscous stress. Nonlinear single-helicity computations with experimentally relevant {rho}{sub s} values show that the warm-ion gyroviscous effects reduce saturated-island widths. Computations with multiple nonlinearly interacting tearing fluctuations find that m = 1 core-resonant-fluctuation amplitudes are reduced by a factor of two relative to single-fluid modeling by the warm-ion effects. These reduced core-resonant-fluctuation amplitudes compare favorably to edge coil measurements in the Madison Symmetric Torus (MST) reversed-field pinch [R. N. Dexter et al., Fusion Technol. 19, 131 (1991)]. The computations demonstrate that fluctuations induce both MHD- and Hall-dynamo emfs during relaxation events. The presence of a Hall-dynamo emf implies a fluctuation-induced Maxwell stress, and the simulation results show net transport of parallel momentum. The computed magnitude of force densities from the Maxwell and competing Reynolds stresses, and changes in the parallel flow profile, are qualitatively and semi-quantitatively similar to measurements during relaxation in MST.« less

  20. A Disposable Tear Glucose Biosensor—Part 1: Design and Concept Testing

    PubMed Central

    Bishop, Daniel K.; La Belle, Jeffrey T.; Vossler, Stephen R.; Patel, Dharmendra R.; Cook, Curtiss B.

    2010-01-01

    Background Tear glucose has been suggested previously as a potential approach for the noninvasive estimation of blood glucose. While the topic remains unresolved, an overview of previous studies suggests the importance of a tear sampling approach and warrants new technology development. A concept device is presented that meets the needs of a tear glucose biosensor. Methods Three approaches to chronoamperometric glucose sensing were evaluated, including glucose oxidase mediated by potassium ferricyanide or oxygen with a hydrogen peroxide catalyst, Prussian blue, and potassium ferricyanide-mediated glucose dehydrogenase. For tear sampling, calcium alginate, poly(2-hydroxyethyl methacrylate), and polyurethane foam were screened as an absorbent tear sampling material. A quantitative model based on the proposed function of concept device was created. Results For glucose sensing, it was found that potassium ferricyanide with glucose dehydrogenase was ideal, featuring oxygen insensitivity, long-term stability, and a lower limit of detection of 2 μM glucose. Polyurethane foam possessed all of the required characteristics for tear sampling, including reproducible sampling from a hydrogel-simulated, eye surface (4.2 ± 0.5 μl; n = 8). It is estimated that 100 μM of glucose tear fluid would yield 135 nA (14.9% relative standard deviation). Conclusion A novel concept device for tear glucose sampling was presented, and the key functions of this device were tested and used to model the performance of the final device. Based on these promising initial results, the device is achievable and within reach of current technical capabilities, setting the stage for prototype development. PMID:20307389

  1. Impact of Flow Rate, Collection Devices, and Extraction Methods on Tear Concentrations Following Oral Administration of Doxycycline in Dogs and Cats.

    PubMed

    Sebbag, Lionel; Showman, Lucas; McDowell, Emily M; Perera, Ann; Mochel, Jonathan P

    2018-04-30

    Compare the precision of doxycycline quantification in tear fluid collected with either Schirmer strips or polyvinyl acetal (PVA) sponges following oral drug administration. Three dogs and 3 cats were administered doxycycline orally at a dose of 4.2-5 mg/kg every 12 h for 6 consecutive days. At day 5 and 6, blood and tear fluid were sampled to capture doxycycline trough and maximal concentrations. Tear fluid was collected 3 times (spaced 10 min apart) at each session with the absorbent material placed in the lower conjunctival fornix until the 20-mm mark was reached (Schirmer strip, one eye) or for 1 min (PVA sponge, other eye). Tear extraction was performed with either centrifugation or elution in methanol. Doxycycline concentrations were measured with liquid chromatography-mass spectrometry. Low (100 ng/mL) and high (1,000 ng/mL) tear concentrations measured in vivo were spiked into each absorbent material in vitro to evaluate percentage drug recovery. After oral administration of doxycycline, the drug reached the tear compartment at concentrations of 45.1-900.7 ng/mL in cats and 45.4-632.0 ng/mL in dogs, representing a tear-to-serum ratio of 12% and 16%, respectively. Doxycycline tear concentrations were significantly more precise when tear collection was performed with Schirmer strips rather than PVA sponges (P = 0.007), but were not correlated with tear flow rate. In vitro doxycycline recovery was poor to moderate (<75%). Schirmer strips represent a good option for lacrimal doxycycline quantification, although the collection and subsequent extraction have to be optimized to improve drug recovery.

  2. A Disposable Tear Glucose Biosensor—Part 2: System Integration and Model Validation

    PubMed Central

    La Belle, Jeffrey T.; Bishop, Daniel K.; Vossler, Stephen R.; Patel, Dharmendra R.; Cook, Curtiss B.

    2010-01-01

    Background We presented a concept for a tear glucose sensor system in an article by Bishop and colleagues in this issue of Journal of Diabetes Science and Technology. A unique solution to collect tear fluid and measure glucose was developed. Individual components were selected, tested, and optimized, and system error modeling was performed. Further data on prototype testing are now provided. Methods An integrated fluidics portion of the prototype was designed, cast, and tested. A sensor was created using screen-printed sensors integrated with a silicone rubber fluidics system and absorbent polyurethane foam. A simulated eye surface was prepared using fluid-saturated poly(2-hydroxyethyl methacrylate) sheets, and the disposable prototype was tested for both reproducibility at 0, 200, and 400 μM glucose (n = 7) and dynamic range of glucose detection from 0 to 1000 μM glucose. Results From the replicated runs, an established relative standard deviation of 15.8% was calculated at 200 μM and a lower limit of detection was calculated at 43.4 μM. A linear dynamic range was demonstrated from 0 to 1000 μM with an R2 of 99.56%. The previously developed model predicted a 14.9% variation. This compares to the observed variance of 15.8% measured at 200 μM glucose. Conclusion With the newly designed fluidics component, an integrated tear glucose prototype was assembled and tested. Testing of this integrated prototype demonstrated a satisfactory lower limit of detection for measuring glucose concentration in tears and was reproducible across a physiological sampling range. The next step in the device design process will be initial animal studies to evaluate the current prototype for factors such as eye irritation, ease of use, and correlation with blood glucose. PMID:20307390

  3. A disposable tear glucose biosensor-part 2: system integration and model validation.

    PubMed

    La Belle, Jeffrey T; Bishop, Daniel K; Vossler, Stephen R; Patel, Dharmendra R; Cook, Curtiss B

    2010-03-01

    We presented a concept for a tear glucose sensor system in an article by Bishop and colleagues in this issue of Journal of Diabetes Science and Technology. A unique solution to collect tear fluid and measure glucose was developed. Individual components were selected, tested, and optimized, and system error modeling was performed. Further data on prototype testing are now provided. An integrated fluidics portion of the prototype was designed, cast, and tested. A sensor was created using screen-printed sensors integrated with a silicone rubber fluidics system and absorbent polyurethane foam. A simulated eye surface was prepared using fluid-saturated poly(2-hydroxyethyl methacrylate) sheets, and the disposable prototype was tested for both reproducibility at 0, 200, and 400 microM glucose (n = 7) and dynamic range of glucose detection from 0 to 1000 microM glucose. From the replicated runs, an established relative standard deviation of 15.8% was calculated at 200 microM and a lower limit of detection was calculated at 43.4 microM. A linear dynamic range was demonstrated from 0 to 1000 microM with an R(2) of 99.56%. The previously developed model predicted a 14.9% variation. This compares to the observed variance of 15.8% measured at 200 microM glucose. With the newly designed fluidics component, an integrated tear glucose prototype was assembled and tested. Testing of this integrated prototype demonstrated a satisfactory lower limit of detection for measuring glucose concentration in tears and was reproducible across a physiological sampling range. The next step in the device design process will be initial animal studies to evaluate the current prototype for factors such as eye irritation, ease of use, and correlation with blood glucose. (c) 2010 Diabetes Technology Society.

  4. Conversion of the dominantly ideal perturbations into a tearing mode after a sawtooth crash

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Igochine, V., E-mail: valentin.igochine@ipp.mpg.de; Gude, A.; Günter, S.

    2014-11-15

    Forced magnetic reconnection is a topic of common interest in astrophysics, space science, and magnetic fusion research. The tearing mode formation process after sawtooth crashes implies the existence of this type of magnetic reconnection and is investigated in great detail in the ASDEX Upgrade tokamak. The sawtooth crash provides a fast relaxation of the core plasma temperature and can trigger a tearing mode at a neighbouring resonant surface. It is demonstrated for the first time that the sawtooth crash leads to a dominantly ideal kink mode formation at the resonant surface immediately after the sawtooth crash. Local measurements show thatmore » this kink mode transforms into a tearing mode on a much longer timescale (10{sup −3}s−10{sup −2}s) than the sawtooth crash itself (10{sup −4}s). The ideal kink mode formed after the sawtooth crash provides the driving force for magnetic reconnection and its amplitude is one of the critical parameters for the length of the transition phase from a ideal into an resistive mode. Nonlinear two fluid MHD simulations confirm these observations.« less

  5. Explosive magnetic reconnection caused by an X-shaped current-vortex layer in a collisionless plasma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hirota, M.; Hattori, Y.; Morrison, P. J.

    2015-05-15

    A mechanism for explosive magnetic reconnection is investigated by analyzing the nonlinear evolution of a collisionless tearing mode in a two-fluid model that includes the effects of electron inertia and temperature. These effects cooperatively enable a fast reconnection by forming an X-shaped current-vortex layer centered at the reconnection point. A high-resolution simulation of this model for an unprecedentedly small electron skin depth d{sub e} and ion-sound gyroradius ρ{sub s}, satisfying d{sub e}=ρ{sub s}, shows an explosive tendency for nonlinear growth of the tearing mode, where it is newly found that the explosive widening of the X-shaped layer occurs locally aroundmore » the reconnection point with the length of the X shape being shorter than the domain length and the wavelength of the linear tearing mode. The reason for the onset of this locally enhanced reconnection is explained theoretically by developing a novel nonlinear and nonequilibrium inner solution that models the local X-shaped layer, and then matching it to an outer solution that is approximated by a linear tearing eigenmode with a shorter wavelength than the domain length. This theoretical model proves that the local reconnection can release the magnetic energy more efficiently than the global one and the estimated scaling of the explosive growth rate agrees well with the simulation results.« less

  6. Center for Extended Magnetohydrodynamics Modeling - Final Technical Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Parker, Scott

    This project funding supported approximately 74 percent of a Ph.D. graduate student, not including costs of travel and supplies. We had a highly successful research project including the development of a second-order implicit electromagnetic kinetic ion hybrid model [Cheng 2013, Sturdevant 2016], direct comparisons with the extended MHD NIMROD code and kinetic simulation [Schnack 2013], modeling of slab tearing modes using the fully kinetic ion hybrid model and finally, modeling global tearing modes in cylindrical geometry using gyrokinetic simulation [Chen 2015, Chen 2016]. We developed an electromagnetic second-order implicit kinetic ion fluid electron hybrid model [Cheng 2013]. As a firstmore » step, we assumed isothermal electrons, but have included drift-kinetic electrons in similar models [Chen 2011]. We used this simulation to study the nonlinear evolution of the tearing mode in slab geometry, including nonlinear evolution and saturation [Cheng 2013]. Later, we compared this model directly to extended MHD calculations using the NIMROD code [Schnack 2013]. In this study, we investigated the ion-temperature-gradient instability with an extended MHD code for the first time and got reasonable agreement with the kinetic calculation in terms of linear frequency, growth rate and mode structure. We then extended this model to include orbit averaging and sub-cycling of the ions and compared directly to gyrokinetic theory [Sturdevant 2016]. This work was highlighted in an Invited Talk at the International Conference on the Numerical Simulation of Plasmas in 2015. The orbit averaging sub-cycling multi-scale algorithm is amenable to hybrid architectures with GPUS or math co-processors. Additionally, our participation in the Center for Extend Magnetohydrodynamics motivated our research on developing the capability for gyrokinetic simulation to model a global tearing mode. We did this in cylindrical geometry where the results could be benchmarked with existing eigenmode calculations. First, we developed a gyrokinetic code capable of simulating long wavelengths using a fluid electron model [Chen 2015]. We benchmarked this code with an eigenmode calculation. Besides having to rewrite the field solver due to the breakdown in the gyrokinetic ordering for long wavelengths, very high radial resolution was required. We developed a technique where we used the solution from the eigenmode solver to specify radial boundary conditions allowing for a very high radial resolution of the inner solution. Using this technique enabled us to use our direct algorithm with gyrokinetic ions and drift kinetic electrons [Chen 2016]. This work was highlighted in an Invited Talk at the American Physical Society - Division of Plasma Physics in 2015.« less

  7. Computational study of haemodynamic effects of entry- and exit-tear coverage in a DeBakey type III aortic dissection: technical report.

    PubMed

    Karmonik, C; Bismuth, J; Shah, D J; Davies, M G; Purdy, D; Lumsden, A B

    2011-08-01

    Outcome prediction in DeBakey Type III aortic dissections (ADs) remains challenging. Large variations in AD morphology, physiology and treatment exist. Here, we investigate if computational fluid dynamics (CFD) can provide an initial understanding of pressure changes in an AD computational model when covering entry and exit tears and removing the intra-arterial septum (IS). A computational mesh was constructed from magnetic resonance images from one patient (one entrance and one exit tear) and CFD simulations performed (scenario #1). Additional meshes were derived by virtually (1) covering the exit tear (false lumen (FL) thrombus progression) (scenario #2), (2) covering the entrance tear (thoracic endovascular treatment, TEVAR) (scenario #3) and (3) completely removing the IS (fenestration) (scenario #4). Changes in flow patterns and pressures were quantified relative to the initial mesh. Systolic pressures increased for #2 (300 Pa increase) with largest inter-luminal differences distally (2500 Pa). In #3, false lumen pressure decreased essentially to zero. In #4, systolic pressure in combined lumen reduced from 2400 to 800 Pa. CFD results from computational models of a DeBakey type III AD representing separate coverage of entrance and exit tears correlated with clinical experience. The reported results present a preliminary look at a complex clinical problem. Copyright © 2011 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  8. Vascular endothelial growth factor levels in tears of patients with retinal vein occlusion.

    PubMed

    Kasza, M; Balogh, Z; Biro, L; Ujhelyi, B; Damjanovich, J; Csutak, A; Várdai, J; Berta, A; Nagy, V

    2015-09-01

    We measured vascular endothelial growth factor (VEGF) levels in tear fluid and serum in patients with retinal vein occlusion (RVO). Eight patients with RVO due to secondary macular oedema were examined. VEGF levels were measured by enzyme-linked immunosorbent assay. All patients had a full ophthalmic examination (visual acuity, slit lamp biomicroscopy, perimetry, and fluorescein angiography). Central retinal thickness (CRT) was examined using optical coherence tomography (OCT). Tear and serum samples were collected and examinations were performed at diagnosis and 1 and 4 weeks later. VEGF levels in the tears of RVO eyes were significantly higher than in fellow eyes at diagnosis and after both 1 and 4 weeks (paired t test, p1 = 0.01, p2 = 0.02, p3 = 0.006). We found a weak but significant positive correlation between VEGF levels in tear fluid and serum of patients with RVO (r = 0.21), while this correlation tended to be stronger between the fellow eyes and serum levels (r = 0.33). To the best of our knowledge, we are the first to report an increased level of VEGF in the tear fluid of patients with RVO. Alterations of VEGF levels in tears may be useful for determining stages of RVO. This non-invasive and objective method may also be helpful for estimating the severity of macular oedema and efficacy of treatment.

  9. Comparison of Short-Term Effects of Diquafosol and Rebamipide on Mucin 5AC Level on the Rabbit Ocular Surface.

    PubMed

    Hori, Yuichi; Kageyama, Tomofumi; Sakamoto, Asuka; Shiba, Tomoaki; Nakamura, Masatsugu; Maeno, Takatoshi

    To investigate the short-term effects of 2 new secretagogue eye drops for dry eye, 3% diquafosol tetrasodium ophthalmic solution (diquafosol) and 2% rebamipide ophthalmic suspension (rebamipide), on the concentration of mucin 5AC (MUC5AC) in rabbit tear fluid and conjunctival goblet cells. One dose of artificial tears, diquafosol or rebamipide, was instilled into 8 eyes of Japanese white rabbits. MUC5AC concentration in the tear fluid was examined using the enzyme-linked immunosorbent assay 15 min after instillation and compared with 8 untreated controls. Impression cytology was performed to measure the number of periodic acid Schiff (PAS)-positive cells and the ratio of the PAS-positive area using image analysis software. Statistical comparison was performed using ANOVA with post hoc analysis with the Tukey's test. After 15 min, only diquafosol significantly (P ≤ 0.01) increased the MUC5AC level in the tear fluid. Although no drug affected the number of PAS-positive cells, the ratio of the PAS-positive area decreased significantly (P ≤ 0.01) only in the diquafosol group. These data indicated that more PAS-positive MUC5AC was released into the tear fluid from the goblet cells by diquafosol than by rebamipide. There is a difference in the induction pattern of MUC5AC into the tears from the goblet cells between these eye drops.

  10. Comparison of camel tear proteins between summer and winter

    PubMed Central

    Chen, Ziyan; Shamsi, Farrukh A.; Li, Kaijun; Huang, Qiang; Al-Rajhi, Ali A.; Chaudhry, Imtiaz A.

    2011-01-01

    Purpose Proteins in the tear fluid have positive effects on maintaining the integrity and stabilization of the tear film, which is affected by several environmental factors. The aim of this study is to investigate seasonal variation of protein patterns in camel tears collected during the summer and winter season. Methods Tears from both eyes of 50 clinically normal camels (Camelus dromedarius) were collected in the summer (June – July) and in the winter (December – January) respectively. Pooled tear protein samples from two seasons were separated by SDS–PAGE and two-dimensional electrophoresis (2-DE). Protein spots of differential expression in two season gels were excised and subjected to in-gel digestion and identification by matrix assisted laser desorption/ionization-time of flight/time of flight-mass spectrum (MALDI-TOF/TOF-MS) analysis. Two differentially expressed proteins, lactoferrin (LF) and vitelline membrane outer layer protein 1 homolog (VMO1 homolog), were validated by western blotting. Results Thirteen well resolved bands were detected in SDS–PAGE gels of both summer and winter camel tears. By band densitometry, significantly higher intensities of band 6, 7, 11, and lower intensity of band 13 were observed in the summer group compared to the winter group. In 2-DE profiles of camel tears, four protein spots were found expressed differentially in two seasons. Further protein identification by MALDI-TOF/TOF-MS and confirmation by western blotting indicated that there was a significant decrease in LF (p=0.002) and an increase in VMO1 homolog (p=0.042) in tears in the summer compared to the winter. Conclusions The seasonal variation of camel tear fluids has been found in the composition of proteins, including LF and VMO1 homolog. This result will expand our knowledge of physiologic characteristics of tear fluids and establish a foundation for the mechanistic studies and clinical practices on ocular surface disorders. PMID:21293736

  11. Shifting the IGF-axis: An age-related decline in human tear IGF-1 correlates with clinical signs of dry eye.

    PubMed

    Patel, Roshni; Zhu, Meifang; Robertson, Danielle M

    2018-06-01

    The human corneal epithelium expresses both the insulin-like growth factor type 1 receptor (IGF-1R) and the IGF-1R/insulin receptor (INSR) hybrid. Despite the previous identification of IGF-1 in human tear fluid, little is known regarding the regulation of IGF-1 in tear fluid and its role in corneal epithelial homeostasis. In the present study, we investigated the impact of biological parameters on the concentration of human tear levels of IGF-1. Tear levels of IGF-1 were measured in 41 healthy, human volunteers without any reported symptoms of dry eye. All volunteers underwent standard biomicroscopic examination of the cornea and tear film. In a subgroup of volunteers, corneal staining with sodium fluorescein, tear film break up time and tear production using a Schirmer's test strip were measured to assess clinical signs of dry eye. Tears were collected from the inferior tear meniscus using glass microcapillary tubes and IGF-1 levels were measured using a solid phase sandwich ELISA. Tear levels of IGF-1 were highest in young adults and significantly decreased in older adults (P = 0.003). There were no differences in tear IGF-1 between males and females (P = 0.628). Tear IGF-1 levels were correlated with tear film break up time (R = 0.738) and tear production (R = 0.826). These data indicate that there is a progressive decline in tear IGF-1 due to aging that is associated with clinical signs of dry eye. This effect is likely due to age-related changes in the lacrimal gland. Copyright © 2018 Elsevier Ltd. All rights reserved.

  12. Environmental Stability and Infectivity of Hepatitis C Virus (HCV) in Different Human Body Fluids.

    PubMed

    Pfaender, Stephanie; Helfritz, Fabian A; Siddharta, Anindya; Todt, Daniel; Behrendt, Patrick; Heyden, Julia; Riebesehl, Nina; Willmann, Wiebke; Steinmann, Joerg; Münch, Jan; Ciesek, Sandra; Steinmann, Eike

    2018-01-01

    Background: Hepatitis C virus (HCV) is a hepatotropic, blood-borne virus, but in up to one-third of infections of the transmission route remained unidentified. Viral genome copies of HCV have been identified in several body fluids, however, non-parental transmission upon exposure to contaminated body fluids seems to be rare. Several body fluids, e.g., tears and saliva, are renowned for their antimicrobial and antiviral properties, nevertheless, HCV stability has never been systematically analyzed in those fluids. Methods: We used state of the art infectious HCV cell culture techniques to investigate the stability of HCV in different body fluids to estimate the potential risk of transmission via patient body fluid material. In addition, we mimicked a potential contamination of HCV in tear fluid and analyzed which impact commercially available contact lens solutions might have in such a scenario. Results: We could demonstrate that HCV remains infectious over several days in body fluids like tears, saliva, semen, and cerebrospinal fluid. Only hydrogen-peroxide contact lens solutions were able to efficiently inactivate HCV in a suspension test. Conclusion: These results indicate that HCV, once it is present in various body fluids of infected patients, remains infective and could potentially contribute to transmission upon direct contact.

  13. In vitro and in vivo ocular safety and eye surface permanence determination by direct and Magnetic Resonance Imaging of ion-sensitive hydrogels based on gellan gum and kappa-carrageenan.

    PubMed

    Fernández-Ferreiro, Anxo; González Barcia, Miguel; Gil-Martínez, María; Vieites-Prado, Alba; Lema, Isabel; Argibay, Barbara; Blanco Méndez, José; Lamas, Maria Jesus; Otero-Espinar, Francisco Javier

    2015-08-01

    Gellan gum, kappa-carrageenan and alginates are natural polysaccharides able to interact with different cations that can be used to elaborate ion-activated in situ gelling systems for different uses. The interaction between fluid solutions of these polysaccharides and cations presents into the tear made these biopolymers very interesting to elaborate ophthalmic drug delivery systems. The main purpose of this study is to evaluate the ability of mixtures of these polymers to obtain ion-activated ophthalmic in situ gelling systems with optimal properties for ocular use. To achieve this purpose different proportion of the biopolymers were analyzed using a mixture experimental design evaluating their transparency, mechanical properties and bioadhesion in the absence and presence of simulated tear fluid. Tear induces a rapid sol-to-gel phase transition in the mixtures forming a consistent hydrogel. The solution composed by 80% of gellan gum and 20% kappa-carrageenan showed the best mechanical and mucoadhesive properties. This mixture was evaluated for rheological behavior, microstructure, cytotoxicity, acute corneal irritancy, ex-vivo and in vivo ocular toxicity and in vivo corneal contact time using Magnetic Resonance Images (MRI) techniques. Result indicates that the system is safe at ophthalmic level and produces an extensive ocular permanence higher than 6h. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Modeling of RF/MHD coupling using NIMROD and GENRAY

    NASA Astrophysics Data System (ADS)

    Jenkins, Thomas G.; Schnack, D. D.; Sovinec, C. R.; Hegna, C. C.; Callen, J. D.; Ebrahimi, F.; Kruger, S. E.; Carlsson, J.; Held, E. D.; Ji, J.-Y.; Harvey, R. W.; Smirnov, A. P.

    2008-11-01

    We summarize ongoing theoretical/numerical work relevant to the development of a self--consistent framework for the inclusion of RF effects in fluid simulations, specifically considering the stabilization of resistive tearing modes in tokamak (DIII--D--like) geometry by electron cyclotron current drive. Previous investigations [T. G. Jenkins et al., Bull. APS 52, 131 (2007)] have demonstrated that relatively simple (though non--self--consistent) models for the RF--induced currents can be incorporated into the fluid equations, and that these currents can markedly reduce the width of the nonlinearly saturated magnetic islands generated by tearing modes. We report our progress toward the self--consistent modeling of these RF--induced currents. The initial interfacing of the NIMROD* code with the GENRAY/CQL3D** codes (which calculate RF propagation and energy/momentum deposition) is explained, equilibration of RF--induced currents over the plasma flux surfaces is investigated, and initial studies exploring the efficient reduction of saturated island widths through time modulation of the ECCD are presented. Conducted as part of the SWIM*** project; funded by U. S. DoE. *www.nimrodteam.org **www.compxco.com ***www.cswim.org

  15. Antibody Protein Array Analysis of the Tear Film Cytokines

    PubMed Central

    Li, Shimin; Sack, Robert; Vijmasi, Trinka; Sathe, Sonal; Beaton, Ann; Quigley, David; Gallup, Marianne; McNamara, Nancy A.

    2013-01-01

    Purpose Many bioactive proteins including cytokines are reported to increase in dry eye disease although the specific profile and concentration of inflammatory mediators varies considerably from study to study. In part this variability results from inherent difficulties in quantifying low abundance proteins in a limited sample volume using relatively low sensitivity dot ELISA methods. Additional complexity comes with the use of pooled samples collected using a variety of techniques and intrinsic variation in the diurnal pattern of individual tear proteins. The current study describes a recent advance in the area of proteomics that has allowed the identification of dozens of low abundance proteins in human tear samples. Methods Commercially available stationary phase antibody protein arrays were adapted to improve suitability for use in small volume biological fluid analysis with particular emphasis on tear film proteomics. Arrays were adapted to allow simultaneous screening for a panel of inflammatory cytokines in low volume tear samples collected from individual eyes. Results A preliminary study comparing tear array results in a small population of Sjögren’s syndrome patients was conducted. The multiplex microplate array assays of cytokines in tear fluid present an unanticipated challenge due to the unique nature of tear fluid. The presence of factors that exhibit an affinity for plastic, capture antibodies and IgG and create a complex series of matrix effects profoundly impacting the reliability of dot ELISA, including with elevated levels of background reactivity and reduction in capacity to bind targeted protein. Conclusions Preliminary results using tears collected from patients with Sjögren’s syndrome reveal methodological advantages of protein array technology and support the concept that autoimmune-mediated dry eye disease has an inflammatory component. They also emphasize the inherent difficulties one can face when interpreting the results of micro-well arrays that result from blooming effects, matrix effects, image saturation and cross-talk between capture and probe antibodies that can greatly reduce signal-to-noise and limit the ability to obtain meaningful results. PMID:18677223

  16. Upper airway compromise by extravasated fluid: a rare complication after arthroscopic repair of atrophic cuff tear.

    PubMed

    Venkat, Gorthi; Moon, Young Lae; Na, Woong Chae; So, Keum Young

    2009-10-01

    During arthroscopic procedures, leakage of irrigation fluid into surrounding tissue planes is a frequently noticed phenomenon usually clinically asymptomatic and resolving within 12 hours postoperatively. Although rare, this fluid may produce life-threatening complications such as airway compromise. This article describes a case of upper airway obstruction in a 60-year-old man undergoing arthroscopic repair for an atrophic rotator cuff tear. The patient presented with a 6-month history of pain and weakness in the left shoulder. Magnetic resonance imaging studies revealed a massive rotator cuff tear with significant retraction and fatty degeneration of cuff musculature. Perioperatively, all vital cardiorespiratory parameters were within normal limits. Postoperatively, immediately on extubation, he was dyspneic, and examination revealed a diffuse swelling extending from the left shoulder up to the neck and face. He was reintubated and sent to the recovery room, where he recovered 12 hours later. This article highlights the possibility of respiratory compromise due to the extravasation of irrigation fluid into the neck and chest during arthroscopic repair of massive and atrophied cuff tears, even with shorter surgical time as is this case. The widened suprascapular space will offer less resistance to the spread of fluid into the neck and chest from the shoulder. We advocate monitoring the patient continuously to prevent this serious complication from becoming life-threatening.

  17. Antioxidant content and ultraviolet absorption characteristics of human tears.

    PubMed

    Choy, Camus Kar Man; Cho, Pauline; Benzie, Iris F F

    2011-04-01

    Dry eye syndrome is a common age-related disorder, and decreased antioxidant/ultraviolet (UV) radiation protection in tears may be part of the cause. This study aimed to compare the tear antioxidant content and flow rate in young and older adults. The total antioxidant content and UV absorbing properties of various commercially available ophthalmic solutions used to alleviate dry eye symptoms were also examined. Minimally stimulated tears were collected from 120 healthy Chinese adults with no ocular pathology. Two age groups were studied: 19 to 29 years (n = 58) and 50 to 75 years (n = 62). Tear samples from each subject and 13 ophthalmic solutions were analyzed for total antioxidant content (as the Ferric Reducing/Antioxidant Power value). Tear flow rates were estimated from time taken to collect a fixed volume of tear fluid. UV absorbance spectra of pooled fresh reflex tear fluid and the ophthalmic solutions were determined. Results showed that the antioxidant content of minimally stimulated tears from older subjects (398 ± 160 μmol/l) was not significantly lower than that of younger subjects (348 ± 159 μmol/l; p = 0.0915). However, there was a significant difference in the tear flow rates between the two groups (p < 0.0001), with the younger group having three to four fold higher flow rate. None of the commercial preparations tested had detectable antioxidant content, and none showed the UV absorption characteristics of natural reflex tears. The effect of low flow rate on the dynamic antioxidant supply to the corneal surface indicates that older subjects have poorer overall defense against photooxidative and other oxidative processes. This could predispose older persons to corneal stress and development of dry eye syndrome. The commercially available artificial tears tested lack both the antioxidant content and UV absorbing characteristics of natural tears. Artificial tears formulations that help restore natural antioxidant and UV absorbing properties to the tear film of the aging eye may help prevent or improve dry eye symptoms and promote ocular health.

  18. Tears from children with chronic hepatitis B virus (HBV) infection are infectious vehicles of HBV transmission: experimental transmission of HBV by tears, using mice with chimeric human livers.

    PubMed

    Komatsu, Haruki; Inui, Ayano; Sogo, Tsuyoshi; Tateno, Akihiko; Shimokawa, Reiko; Fujisawa, Tomoo

    2012-08-15

    Body fluids such as saliva, urine, sweat, and tears from hepatitis B virus (HBV) carriers are potential sources of HBV transmission. Thirty-nine children and 8 adults who were chronically infected with HBV were enrolled. Real-time polymerase chain reaction was used for the quantification of HBV DNA. HBV DNA was detected in 73.7% of urine samples (14 of 19), 86.8% of saliva samples (33 of 38), 100% of tear samples (11 of 11), and 100% of sweat samples (9 of 9). Mean HBV DNA levels (±SD) in urine, saliva, tears, and sweat were 4.3 ± 1.1 log copies/mL, 5.9 ± 1.2 log copies/mL, 6.2 ± 0.7 log copies/mL, and 5.2 ± 0.6 log copies/mL, respectively. A statistically significant correlation was observed between the HBV DNA level in serum specimens and HBV DNA levels in saliva and tear specimens (r = 0.88; P < .001). Tear specimens from a child were injected intravenously into 2 human hepatocyte-transplanted chimeric mice. One week after inoculation, both chimeric mice had serum positive for HBV DNA. The levels of HBV DNA in tear specimens from young children were high. Tears were confirmed to be infectious, using chimeric mice. Strict precautions should be taken against direct contact with body fluids from HBV carriers with high-level viremia.

  19. Paper-basd surface enhanced Raman spectroscopy of pnenobarbital sodium for point-of-care therapeutic drug monitoring

    NASA Astrophysics Data System (ADS)

    Yokoyama, Moe; Yamada, Kenji; Nishimura, Takahiro; Kido, Michiko; Jeong, Hieyong; Ohno, Yuko

    2015-03-01

    Therapeutic drug monitoring (TDM) contributes to safe and effective pharmacotherapy in clinical fields. A simple, rapid, low-cost, and minimally-invasive drug measurement method attracts much interest for point-of-care TDM. Tear fluids can be collected minimally-invasively compared to blood sampling and there is a correlation between a drug concentration in tears and that in bloods. Surface enhanced Raman spectroscopy (SERS) with paper-based substrate is useful for point-of-care TDM owing to inexpensiveness and high-sensitivity. Paper is also a safe tear collection tool. Then we are studying on a paper-based SERS of tear specimen for point-of-care TDM. In this paper, to improve sensitivity in measuring drug concentration in tear fluids, we fabricated a SERS substrate by coating gold nano-rods on a paper substrate and evaluated whether the fabricated substrate can enhance Raman scattering. Sodium phenobarbital (PB), an anti-convulsant agent, was used as a target. In experiment, the fabricated substrate indicated the lower detection limit of PB in a solution than a plain paper substrate. This result showed the potential of the paper based SERS substrate to measure drug concentration in tears simply and inexpensively.

  20. Development and Validation of Different Ultraviolet-Spectrophotometric Methods for the Estimation of Besifloxacin in Different Simulated Body Fluids.

    PubMed

    Singh, C L; Singh, A; Kumar, S; Kumar, M; Sharma, P K; Majumdar, D K

    2015-01-01

    In the present study a simple, accurate, precise, economical and specific UV-spectrophotometric method for estimation of besifloxacin in bulk and in different pharmaceutical formulation has been developed. The drug shows maximum λmax289 nm in distilled water, simulated tears and phosphate buffer saline. The linearity range of developed methods were in the range of 3-30 μg/ml of drug with a correlation coefficient (r(2)) 0.9992, 0.9989 and 0.9984 with respect to distilled water, simulated tears and phosphate buffer saline, respectively. Reproducibility by repeating methods as %RSD were found to be less than 2%. The limit of detection in different media was found to be 0.62, 0.72 and 0.88 μg/ml, respectively. The limit of quantification was found to be 1.88, 2.10, 2.60 μg/ml, respectively. The proposed method was validated statically according to International Conference on Harmonization guidelines with respect to specificity, linearity, range, accuracy, precision and robustness. The proposed methods of validation were found to be accurate and highly specific for the estimation of besifloxacin in different pharmaceutical formulations.

  1. Next-generation confirmatory disease diagnostics

    NASA Astrophysics Data System (ADS)

    Lin, Robert; Gerver, Rachel; Karns, Kelly; Apori, Akwasi A.; Denisin, Aleksandra K.; Herr, Amy E.

    2014-06-01

    Microfluidic tools are advancing capabilities in screening diagnostics for use in near-patient settings. Here, we review three case studies to illustrate the flexibility and analytical power offered by microanalytical tools. We first overview a near-patient tool for detection of protein markers found in cerebrospinal fluid (CSF), as a means to identify the presence of cerebrospinal fluid in nasal mucous - an indication that CSF is leaking into the nasal cavity. Microfluidic design allowed integration of several up-stream preparatory steps and rapid, specific completion of the human CSF protein assay. Second, we overview a tear fluid based assay for lactoferrin, a protein produced in the lacrimal gland, then secreted into tear fluid. Tear Lf is a putative biomarker for primary SS. A critical contribution of this and related work being measurement of Lf, even in light of well-known and significant matrix interactions and losses during the tear fluid collection and preparation. Lastly, we review a microfluidic barcode platform that enables rapid measurement of multiple infectious disease biomarkers in human sera. The assay presents a new approach to multiplexed biomarker detection, yet in a simple straight microchannel - thus providing a streamlined, simplified microanalytical platform, as is relevant to robust operation in diagnostic settings. We view microfluidic design and analytical chemistry as the basis for emerging, sophisticated assays that will advance not just screening diagnostic technology, but confirmatory assays, sample preparation and handling, and thus introduction and utilization of new biomarkers and assay formats.

  2. A Case Report of an Acromioclavicular Joint Ganglion Associated with a Rotator Cuff Tear.

    PubMed

    Tanaka, Suguru; Gotoh, Masafumi; Mitsui, Yasuhiro; Shirachi, Isao; Okawa, Takahiro; Higuchi, Fujio; Shiba, Naoto

    2017-04-13

    We report a case of subcutaneous ganglion adjacent to the acromioclavicular joint with massive rotator cuff tear [1-7]. An 81-year-old woman presented with a ganglion adjacent to the acromioclavicular joint that had first been identified 9 months earlier. The ganglion had recurred after having been aspirated by her local physician, so she was referred to our hospital. The puncture fluid was yellowish, clear and viscous. Magnetic resonance imaging identified a massive rotator cuff tear with multi- lobular cystic lesions continuous to the acromioclavicular joint, presenting the "geyser sign". During arthroscopy, distal clavicular resection and excision of the ganglion were performed together with joint debridement. At present, the ganglion has not recurred and the patient has returned to normal daily activity. In this case, the ganglion may have developed subsequent to the concomitant massive cuff tear, due to subcutaneous fluid flow through the damaged acromioclavicular joint.

  3. Tear exchange and contact lenses: A review

    PubMed Central

    Muntz, Alex; Subbaraman, Lakshman N.; Sorbara, Luigina; Jones, Lyndon

    2015-01-01

    Tear exchange beneath a contact lens facilitates ongoing fluid replenishment between the ocular surface and the lens. This exchange is considerably lower during the wear of soft lenses compared with rigid lenses. As a result, the accumulation of tear film debris and metabolic by-products between the cornea and a soft contact lens increases, potentially leading to complications. Lens design innovations have been proposed, but no substantial improvement in soft lens tear exchange has been reported. Researchers have determined post-lens tear exchange using several methods, notably fluorophotometry. However, due to technological limitations, little remains known about tear hydrodynamics around the lens and, to-date, true tear exchange with contact lenses has not been shown. Further knowledge regarding tear exchange could be vital in aiding better contact lens design, with the prospect of alleviating certain adverse ocular responses. This article reviews the literature to-date on the significance, implications and measurement of tear exchange with contact lenses. PMID:25575892

  4. Detection of sialomucin complex (MUC4) in human ocular surface epithelium and tear fluid.

    PubMed

    Pflugfelder, S C; Liu, Z; Monroy, D; Li, D Q; Carvajal, M E; Price-Schiavi, S A; Idris, N; Solomon, A; Perez, A; Carraway, K L

    2000-05-01

    To evaluate human ocular surface epithelium and tear fluid for the presence of sialomucin complex (MUC4), a high-molecular-weight heterodimeric glycoprotein composed of mucin (ASGP-1) and transmembrane (ASGP-2) subunits. Reverse transcription-polymerase chain reaction (RT-PCR) and Northern blot analysis assays were used to identify sialomucin complex RNA in ocular surface epithelia. Immunoprecipitation and immunoblot analysis were used to identify immunoreactive species in human tears and in the corneal and conjunctival epithelia using antibodies specific for carbohydrate and peptide epitopes on the sialomucin complex subunits. Immunofluorescence staining was used to detect sialomucin complex in frozen sections and impression cytology specimens of human cornea and conjunctival epithelia. ASGP-1- and ASGP-2-specific sequences were amplified from RNA extracted from both conjunctival and corneal epithelial biopsies by RT-PCR. Sialomucin complex transcripts were also detected in these tissues by Northern blot analysis, with a greater level of RNA detected in the peripheral than the central corneal epithelium. Sialomucin complex was immunoprecipitated from tear fluid samples and both corneal and conjunctival epithelia and detected by immunoblot analysis with specific anti-ASGP-1 and anti-ASGP-2 antibodies. The ASGP-1 peptide antibody HA-1 stained the full thickness of the corneal and conjunctival epithelia. In contrast, antibody 15H10, which reacts against a carbohydrate epitope on ASGP-1, stained only the superficial epithelial layers of these tissues. No staining was observed in the conjunctival goblet cells. Sialomucin complex was originally identified in rat mammary adenocarcinoma cells and has recently been shown to be produced by the ocular surface epithelia of rats. Furthermore, it has been identified as the rat homologue of human MUC4 mucin. The present studies show that it is expressed in the stratified epithelium covering the surface of the human eye and is present in human tear fluid. Expression of a carbohydrate-dependent epitope on the mucin subunit (ASGP-1) of sialomucin complex occurs in a differentiation-dependent fashion. Sialomucin complex joins MUC1 as another membrane mucin produced by the human ocular surface epithelia but is also found in the tear fluid, presumably in a soluble form, as found on the rat ocular surface.

  5. Modelling the evaporation of a tear film over a contact lens.

    PubMed

    Talbott, Kevin; Xu, Amber; Anderson, Daniel M; Seshaiyer, Padmanabhan

    2015-06-01

    A contact lens (CL) separates the tear film into a pre-lens tear film (PrLTF), the fluid layer between the CL and the outside environment, and a post-lens tear film (PoLTF), the fluid layer between the CL and the cornea. We examine a model for evaporation of a PrLTF on a modern permeable CL allowing fluid transfer between the PrLTF and the PoLTF. Evaporation depletes the PrLTF, and continued evaporation causes depletion of the PoLTF via fluid loss through the CL. Governing equations include Navier-Stokes, heat and Darcy's equations for the fluid flow and heat transfer in the PrLTF and porous layer. The PoLTF is modelled by a fixed pressure condition on the posterior surface of the CL. The original model is simplified using lubrication theory for the PrLTF and CL applied to a sagittal plane through the eye. We obtain a partial differential equation (PDE) for the PrLTF thickness that is first-order in time and fourth-order in space. This model incorporates evaporation, conjoining pressure effects in the PrLTF, capillarity and heat transfer. For a planar film, we find that this PDE can be reduced to an ordinary differential equation (ODE) that can be solved analytically or numerically. This reduced model allows for interpretation of the various system parameters and captures most of the basic physics contained in the model. Comparisons of ODE and PDE models, including estimates for the loss of fluid through the lens due to evaporation, are given. © The Authors 2014. Published by Oxford University Press on behalf of the Institute of Mathematics and its Applications. All rights reserved.

  6. Sustained ophthalmic delivery of highly soluble drug using pH-triggered inner layer-embedded contact lens.

    PubMed

    Zhu, Qiang; Cheng, Hongbo; Huo, Yingnan; Mao, Shirui

    2018-06-10

    In the present work the feasibility of using inner layer-embedded contact lenses (CLs) to achieve sustained release of highly water soluble drug, betaxolol hydrochloride (BH) on the ocular surface was investigated. Blend film of cellulose acetate and Eudragit S100 was selected as the inner layer, while silicone hydrogel was used as outer layer to construct inner layer-embedded contact lenses. Influence of polymer ratio in the blend film on in vitro drug release behavior in phosphate buffered solution or simulated tear fluid was studied and drug-polymer interaction, erosion and swelling of the blend film were characterized to better understand drug-release mechanism. Storage stability of the inner layer-embedded contact lenses in phosphate buffer solution was also conducted, with ignorable drug loss and negligible change in drug release pattern within 30 days. In vivo pharmacokinetic study in rabbits showed sustained drug release for over 240 h in tear fluid, indicating prolonged drug precorneal residence time. In conclusion, cellulose acetate/Eudragit S100 inner layer-embedded contact lenses are quite promising as controlled-release carrier of highly water soluble drug for ophthalmic delivery. Copyright © 2018 Elsevier B.V. All rights reserved.

  7. Altered cytokine balance in the tear fluid and conjunctiva of patients with Sjögren's syndrome keratoconjunctivitis sicca.

    PubMed

    Pflugfelder, S C; Jones, D; Ji, Z; Afonso, A; Monroy, D

    1999-09-01

    To compare epidermal growth factor (EGF) concentration in tear fluid and levels of inflammatory cytokines in the conjunctival epithelium of patients with Sjögren's syndrome keratoconjunctivitis sicca with those of normal controls. Schirmer 1 tear testing, corneal fluorescein staining and conjunctival impression cytology for quantitation of goblet cell density were performed in ten patients with Sjögren's syndrome-associated keratoconjunctivitis sicca and ten asymptomatic normal controls. ELISA was used to detect the concentration of EGF in tear fluid and interleukin 6 in lysates of conjunctival cytology specimens obtained from all subjects. The levels of RNA transcripts encoding inflammatory cytokines [interleukin 1alpha_(IL-1alpha), interleukin 6 (IL-6), interleukin 8 (IL-8), tumor necrosis factor alpha_(TNF-alpha), and transforming growth factor beta1 (TGF-beta1)] as well as a housekeeping gene (G3PDH) were evaluated in conjunctival cytology specimens taken from all subjects by semiquantitative competitive reverse transcriptase polymerase chain reaction (RT-PCR). Decreased tear fluid EGF concentration was noted in Sjögren's syndrome patients (mean 0.68 +/- 0.59 ng/ml) compared to controls (mean 1.66 +/- 0.45 ng/ml, P = 0.004). Significantly increased levels of IL-1alpha, IL-6, IL-8, TNF-alpha and TGF-beta1 RNA transcripts were found in the conjunctival epithelium of Sjögren's syndrome patients compared to controls (P < 0.05), while the level of G3PDH was similar in both groups. The concentration of IL-6 protein was significantly higher in Sjögren's syndrome conjunctiva samples (P = 0.012). Tear EGF concentration correlated with Schirmer 1 scores (rho 0.767, P < 0.001), corneal fluorescein staining scores (rho -0.562, P = 0.01), conjunctival goblet cell density (rho 0.661, P = 0.001) and the levels of IL-1alpha_and IL-8 RNA in the conjunctival epithelium (rho -0.677 and -0.747, respectively, P = 0.001). Both IL-1alpha_and IL-8 RNA in the conjunctival epithelium increased as Schirmer 1 scores decreased (P

  8. The effects of 2% rebamipide ophthalmic solution on the tear functions and ocular surface of the superoxide dismutase-1 (sod1) knockout mice.

    PubMed

    Ohguchi, Takeshi; Kojima, Takashi; Ibrahim, Osama M; Nagata, Taeko; Shimizu, Takahiko; Shirasawa, Takuji; Kawakita, Tetsuya; Satake, Yoshiyuki; Tsubota, Kazuo; Shimazaki, Jun; Ishida, Susumu

    2013-11-21

    To investigate the efficacy of 2% rebamipide ophthalmic solution on the tear functions and ocular surface status of the superoxide dismutase-1(Sod1(-/-)) mice. Two percent Rebamipide ophthalmic solution was applied to 40-week-old male Sod1(-/-) and wild-type (WT) mice four times a day for 2 weeks. We examined the cytokine concentrations in the tear fluid (by CytoBead assay), tear film break-up time, amount of tear production, and expressions of mucins 1, 4, and 5AC, by RT-PCR. We also performed vital staining of the ocular surface, PAS staining for muc5AC, and immunohistochemical stainings for 4-hydroxy-2-nonenal (4-HNE), 8-hydroxy-2'-deoxyguanosine (8-OHdG), in the conjunctiva to compare the results before and after rebamipide instillations. The tear functions and ocular surface epithelial damage scores were significantly worse in the Sod1(-/-) than in the WT mice. Application of 2% rebamipide for 2 weeks significantly improved the tear film break-up time, the amount of tear production, and the corneal epithelial damage scores, which also significantly increased the conjunctival goblet cell density and muc5 mRNA expression, in the Sod1(-/-) mice. The mean IL-6, IL-17, TNF-α, and IFN-γ levels in the tear fluid were reduced significantly along with a significant decrease in the density of cells positive for 4-HNE and 8-OHdG in the conjunctiva. Two percent Rebamipide ophthalmic solution significantly improved the tear stability and corneal epithelial damage, and enhanced the expression of muc5 mRNA on the ocular surface. We also observed anti-inflammatory effects in the tear film together with antioxidative effects in the conjunctiva, suggesting the efficacy of rebamipide in age-related dry eye disease attributable to SOD1 knockout.

  9. Development of tearing instability in a current sheet forming by sheared incompressible flow

    NASA Astrophysics Data System (ADS)

    Tolman, Elizabeth A.; Loureiro, Nuno F.; Uzdensky, Dmitri A.

    2018-02-01

    Sweet-Parker current sheets in high Lundquist number plasmas are unstable to tearing, suggesting they will not form in physical systems. Understanding magnetic reconnection thus requires study of the stability of a current sheet as it forms. Formation can occur due to sheared, sub-Alfvénic incompressible flows which narrow the sheet. Standard tearing theory (Furth et al. Phys. Fluids, vol. 6 (4), 1963, pp. 459-484, Rutherford, Phys. Fluids, vol. 16 (11), 1973, pp. 1903-1908, Coppi et al. Fizika Plazmy, vol. 2, 1976, pp. 961-966) is not immediately applicable to such forming sheets for two reasons: first, because the flow introduces terms not present in the standard calculation; second, because the changing equilibrium introduces time dependence to terms which are constant in the standard calculation, complicating the formulation of an eigenvalue problem. This paper adapts standard tearing mode analysis to confront these challenges. In an initial phase when any perturbations are primarily governed by ideal magnetohydrodynamics, a coordinate transformation reveals that the flow compresses and stretches perturbations. A multiple scale formulation describes how linear tearing mode theory (Furth et al. Phys. Fluids, vol. 6 (4), 1963, pp. 459-484, Coppi et al. Fizika Plazmy, vol. 2, 1976, pp. 961-966) can be applied to an equilibrium changing under flow, showing that the flow affects the separable exponential growth only implicitly, by making the standard scalings time dependent. In the nonlinear Rutherford stage, the coordinate transformation shows that standard theory can be adapted by adding to the stationary rates time dependence and an additional term due to the strengthening equilibrium magnetic field. Overall, this understanding supports the use of flow-free scalings with slight modifications to study tearing in a forming sheet.

  10. Tear exchange and contact lenses: a review.

    PubMed

    Muntz, Alex; Subbaraman, Lakshman N; Sorbara, Luigina; Jones, Lyndon

    2015-01-01

    Tear exchange beneath a contact lens facilitates ongoing fluid replenishment between the ocular surface and the lens. This exchange is considerably lower during the wear of soft lenses compared with rigid lenses. As a result, the accumulation of tear film debris and metabolic by-products between the cornea and a soft contact lens increases, potentially leading to complications. Lens design innovations have been proposed, but no substantial improvement in soft lens tear exchange has been reported. Researchers have determined post-lens tear exchange using several methods, notably fluorophotometry. However, due to technological limitations, little remains known about tear hydrodynamics around the lens and, to-date, true tear exchange with contact lenses has not been shown. Further knowledge regarding tear exchange could be vital in aiding better contact lens design, with the prospect of alleviating certain adverse ocular responses. This article reviews the literature to-date on the significance, implications and measurement of tear exchange with contact lenses. Copyright © 2014 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.

  11. Extensive characterization of human tear fluid collected using different techniques unravels the presence of novel lipid amphiphiles1[S

    PubMed Central

    Lam, Sin Man; Tong, Louis; Duan, Xinrui; Petznick, Andrea; Wenk, Markus R.; Shui, Guanghou

    2014-01-01

    The tear film covers the anterior eye and the precise balance of its various constituting components is critical for maintaining ocular health. The composition of the tear film amphiphilic lipid sublayer, in particular, has largely remained a matter of contention due to the limiting concentrations of these lipid amphiphiles in tears that render their detection and accurate quantitation tedious. Using systematic and sensitive lipidomic approaches, we validated different tear collection techniques and report the most comprehensive human tear lipidome to date; comprising more than 600 lipid species from 17 major lipid classes. Our study confers novel insights to the compositional details of the existent tear film model, in particular the disputable amphiphilic lipid sublayer constituents, by demonstrating the presence of cholesteryl sulfate, O-acyl-ω-hydroxyfatty acids, and various sphingolipids and phospholipids in tears. The discovery and quantitation of the relative abundance of various tear lipid amphiphiles reported herein are expected to have a profound impact on the current understanding of the existent human tear film model. PMID:24287120

  12. Immersed boundary peridynamics (IB/PD) method to simulate aortic dissection

    NASA Astrophysics Data System (ADS)

    Bhalla, Amneet Pal Singh; Griffith, Boyce

    2016-11-01

    Aortic dissection occurs when an intimal tear in the aortic wall propagates into the media to form a false lumen within the vessel wall. Rupture of the false lumen and collapse of the true lumen both carry a high risk of morbidity and mortality. Surgical treatment consists of either replacement of a portion of the aorta, or stent implantation to cover the affected segment. Both approaches carry significant risks: open surgical intervention is highly invasive, whereas stents can be challenging to implant and offer unclear long-term patient outcomes. It is also difficult to time optimally the intervention to ensure that the benefits of treatment outweigh its risks. In this work we develop innovative fluid-structure interaction (FSI) model combining elements from immersed boundary (IB) and peridynamics (PD) methods to simulate tears in membranes. The new approach is termed as IB/PD method. We use non-ordinary state based PD to represent material hyperelasticity. Several test problems are taken to validate peridynamics approach to model structural dynamics, with and without accounting for failure in the structures. FSI simulations using IB/PD method are compared with immersed finite element method (IB/FE) to validate the new hybrid approach. NIH Award R01HL117163 NSF Award ACI 1450327.

  13. A 3D coupled hydro-mechanical granular model for the prediction of hot tearing formation

    NASA Astrophysics Data System (ADS)

    Sistaninia, M.; Phillion, A. B.; Drezet, J.-M.; Rappaz, M.

    2012-07-01

    A new 3D coupled hydro-mechanical granular model that simulates hot tearing formation in metallic alloys is presented. The hydro-mechanical model consists of four separate 3D modules. (I) The Solidification Module (SM) is used for generating the initial solid-liquid geometry. Based on a Voronoi tessellation of randomly distributed nucleation centers, this module computes solidification within each polyhedron using a finite element based solute diffusion calculation for each element within the tessellation. (II) The Fluid Flow Module (FFM) calculates the solidification shrinkage and deformation-induced pressure drop within the intergranular liquid. (III) The Semi-solid Deformation Module (SDM) is used to simulate deformation of the granular structure via a combined finite element / discrete element method. In this module, deformation of the solid grains is modeled using an elasto-viscoplastic constitutive law. (IV) The Failure Module (FM) is used to simulate crack initiation and propagation with the fracture criterion estimated from the overpressure required to overcome the capillary forces at the liquid-gas interface. The FFM, SDM, and FM are coupled processes since solid deformation, intergranular flow, and crack initiation are deeply linked together. The granular model predictions have been validated against bulk data measured experimentally and calculated with averaging techniques.

  14. Detection of endogenous cortisol in equine tears and blood at rest and after simulated stress.

    PubMed

    Monk, Caroline S; Hart, Kelsey A; Berghaus, Roy D; Norton, Natalie A; Moore, Phillip A; Myrna, Kathern E

    2014-07-01

    To determine whether cortisol is present in equine tears at rest and during simulated stress and compare tear cortisol to serum free and total cortisol. Fourteen healthy adult horses were included. Paired tear total cortisol and serum total and free cortisol concentrations were measured with ELISA, chemiluminescent immunoassay, and ultrafiltration methodology, respectively, in 10 horses at rest once daily for five consecutive days. In an additional four horses, paired tear and serum samples were collected for cortisol measurement before and after adrenocorticotropic hormone (ACTH) stimulation (cosyntropin, 1 μg/kg IV). Cortisol was detectable in equine tears at rest. Following ACTH stimulation, tear cortisol increased significantly from baseline at 60-120 min (P ≤ 0.001). Serum total and free cortisol also increased significantly at 30-180 min after ACTH stimulation (P ≤ 0.001). Both serum and tear cortisol returned to baseline concentrations by 360 min. Changes in tear cortisol were similarly associated with changes in serum total and free cortisol, although high tear cortisol concentrations suggest a portion of tear cortisol may be protein-bound. Cortisol is present in equine tears and increases in concert with serum cortisol following ACTH stimulation. Further study is needed to determine whether endogenous cortisol in tears contributes to ocular pathology. © 2013 American College of Veterinary Ophthalmologists.

  15. Validation Data and Model Development for Fuel Assembly Response to Seismic Loads

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bardet, Philippe; Ricciardi, Guillaume

    2016-01-31

    Vibrations are inherently present in nuclear reactors, especially in cores and steam generators of pressurized water reactors (PWR). They can have significant effects on local heat transfer and wear and tear in the reactor and often set safety margins. The simulation of these multiphysics phenomena from first principles requires the coupling of several codes, which is one the most challenging tasks in modern computer simulation. Here an ambitious multiphysics multidisciplinary validation campaign is conducted. It relied on an integrated team of experimentalists and code developers to acquire benchmark and validation data for fluid-structure interaction codes. Data are focused on PWRmore » fuel bundle behavior during seismic transients.« less

  16. Laboratory observation of resistive electron tearing in a two-fluid reconnecting current sheet

    DOE PAGES

    Jara-Almonte, Jonathan; Ji, Hantao; Yamada, Masaaki; ...

    2016-08-25

    The spontaneous formation of plasmoids via the resistive electron tearing of a reconnecting current sheet is observed in the laboratory. These experiments are performed during driven, antiparallel reconnection in the two-fluid regime within the Magnetic Reconnection Experiment. It is found that plasmoids are present even at a very low Lundquist number, and the number of plasmoids scales with both the current sheet aspect ratio and the Lundquist number. Furthermore, the reconnection electric field increases when plasmoids are formed, leading to an enhanced reconnection rate.

  17. Dual quantification of dapivirine and maraviroc in cervicovaginal secretions from ophthalmic tear strips and polyester-based swabs via liquid chromatographic-tandem mass spectrometric (LC-MS/MS) analysis.

    PubMed

    Parsons, Teresa L; Emory, Joshua F; Seserko, Lauren A; Aung, Wutyi S; Marzinke, Mark A

    2014-09-01

    Topical microbicidal agents are being actively pursued as a modality to prevent HIV viral transmission during sexual intercourse. Quantification of antiretroviral agents in specimen sources where antiviral activity is elicited is critical, and drug measurements in cervicovaginal fluid can provide key information on local drug concentrations. Two antiretroviral drugs, dapivirine and maraviroc, have gained interest as vaginal microbicidal agents, and rugged methods are required for their quantification in cervicovaginal secretions. Cervicovaginal fluid spiked with dapivirine and maraviroc were applied to ophthalmic tear strips or polyester-based swabs to mimic collection procedures used in clinical studies. Following sample extraction and the addition of isotopically labeled internal standards, samples were subjected to liquid chromatographic-tandem mass spectrometric (LC-MS/MS) analysis using a Waters BEH C8, 50mm×2.1mm, 1.7μm particle size column, on an API 4000 mass analyzer operated in selective reaction monitoring mode. The method was validated according to FDA Bioanalytical Method Validation guidelines. Due to the disparate saturation capacity of the tested collection devices, the analytical measuring ranges for dapivirine and maravirocin cervicovaginal fluid on the ophthalmic tear strip were 0.05-25ng/tear strip, and 0.025-25ng/tear strip, respectively. As for the polyester-based swab, the analytical measuring ranges were 0.25-125ng/swab for dapivirine and 0.125-125ng/swab for maraviroc. Dilutional studies were performed for both analytes to extended ranges of 25,000ng/tear strip and 11,250ng/swab. Standard curves were generated via weighted (1/x(2)) linear or quadratic regression of calibrators. Precision, accuracy, stability and matrix effects studies were all performed and deemed acceptable according to the recommendations of the FDA Bioanalytical Method Validation guidelines. A rugged LC-MS/MS method for the dual quantification of dapivirine and maraviroc in cervicovaginal fluid using two unique collection devices has been developed and validated. The described method meets the criteria to support large research trials. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. Dual Quantification of Dapivirine and Maraviroc in Cervicovaginal Secretions from Ophthalmic Tear Strips and Polyester-Based Swabs via Liquid Chromatographic-Tandem Mass Spectrometric (LC-MS/MS) Analysis

    PubMed Central

    Parsons, Teresa L.; Emory, Joshua F.; Seserko, Lauren A.; Aung, Wutyi S.; Marzinke, Mark A.

    2014-01-01

    Background Topical microbicidal agents are being actively pursued as a modality to prevent HIV viral transmission during sexual intercourse. Quantification of antiretroviral agents in specimen sources where antiviral activity is elicited is critical, and drug measurements in cervicovaginal fluid can provide key information on local drug concentrations. Two antiretroviral drugs, dapivirine and maraviroc, have gained interest as vaginal microbicidal agents, and rugged methods are required for their quantification in cervicovaginal secretions. Methods Cervicovaginal fluid spiked with dapivirine and maraviroc were applied to ophthalmic tear strips or polyester-based swabs to mimic collection procedures used in clinical studies. Following sample extraction and the addition of isotopically-labeled internal standards, samples were subjected to liquid chromatographic-tandem mass spectrometric (LC-MS/MS) analysis using a Waters BEH C8, 50 × 2.1 mm, 1.7 µm particle size column, on an API 4000 mass analyzer operated in selective reaction monitoring mode. The method was validated according to FDA Bioanalytical Method Validation guidelines. Results Due to the disparate saturation capacity of the tested collection devices, the analytical measuring ranges for dapivirine and maravirocin cervicovaginal fluid on the ophthalmic tear strip were 0.05 to 25 ng/tear strip, and 0.025 to 25 ng/tear strip, respectively. As for the polyester-based swab, the analytical measuring ranges were 0.25 to 125 ng/swab for dapivirine and 0.125 to 125 ng/swab for maraviroc. Dilutional studies were performed for both analytes to extended ranges of 25,000 ng/tear strip and 11,250 ng/swab. Standard curves were generated via weighted (1/x2) linear or quadratic regression of calibrators. Precision, accuracy, stability and matrix effects studies were all performed and deemed acceptable according to the recommendations of the FDA Bioanalytical Method Validation guidelines. Conclusions A rugged LC-MS/MS method for the dual quantification of dapivirine and maraviroc in cervicovaginal fluid using two unique collection devices has been developed and validated. The described method meets the criteria to support large research trials. PMID:25005891

  19. Effects of chemosignals from sad tears and postprandial plasma on appetite and food intake in humans.

    PubMed

    Oh, Tae Jung; Kim, Min Young; Park, Kyong Soo; Cho, Young Min

    2012-01-01

    Chemosignals from human body fluids may modulate biological functions in humans. The objective of this study was to examine whether chemosignals from human sad tears and postprandial plasma modulate appetite. We obtained fasting and postprandial plasma from male participants and sad tears and saline, which was trickled below the eyelids, from female volunteers. These samples were then randomly distributed to male participants to sniff with a band-aid containing 100 µl of each fluid on four consecutive days in a double-blind fashion. We checked appetite by a visual analogue scale (VAS) and food intake by measuring the consumption of a test meal. In addition, the serum levels of total testosterone and LH were measured. Twenty men (mean age 26.3±4.6 years) were enrolled in this study. They could not discriminate between the smell of fasting and postprandial plasma and the smell of sad tears and trickled saline. Appetite and the amount of food intake were not different between the groups. Although the VAS ratings of appetite correlated with the food intake upon sniffing fasting plasma, postprandial plasma, and trickled saline, there was no such correlation upon sniffing sad tears. In addition, the decrease in serum testosterone levels from the baseline was greater with sad tears than with the trickled saline (-28.6±3.3% vs. -14.0±5.2%; P = 0.019). These data suggest that chemosignals from human sad tears and postprandial plasma do not appear to reduce appetite and food intake. However, further studies are necessary to examine whether sad tears may alter the appetite-eating behavior relation.

  20. Tear fluid collection in dogs and cats using ophthalmic sponges.

    PubMed

    Sebbag, Lionel; Harrington, Danielle M; Mochel, Jonathan P

    2018-05-01

    To compare the use of two ophthalmic sponges for tear collection in dogs and cats. Ten healthy dogs and 10 healthy cats. A strip (4 × 10 mm) of either cellulose or polyvinyl acetal (PVA) sponge was inserted into the ventral fornix of each eye for either 15, 30, or 60 s. The wetted strip was placed into a 0.2-mL tube that was first punctured at its bottom. Tears were eluted through the drainage hole into a 1.5-mL tube via centrifugation. Tear volume absorbed (VA) and tear volume recovered (VR) were calculated as the difference of the post- and precollection weight of the 0.2-mL tube and 1.5-mL tube, respectively. Recovery ratio (RR) was determined as the ratio between VR and VA. Ophthalmic sponges were well tolerated by all subjects. In dogs and cats, median (95% range) VA, VR, and RR were as follows: 44 μL (11-106 μL) and 16 μL (2-43 μL); 27 μL (1-84 μL) and 6 μL (0-29 μL); 64% (7-91%) and 35% (0-86%), respectively. PVA sponges achieved significantly greater VR in cats and RR in both species. All parameters were significantly greater with a collection time of 60 vs. 30 and 15 s. Body weight was associated with VA and VR in dogs but not cats. Polyvinyl acetal is better than cellulose for tear collection given its superior recovery. Ophthalmic sponges could facilitate routine analysis of tear fluid in dogs and cats, although further studies are needed to evaluate the quality of tears obtained with this method. © 2017 American College of Veterinary Ophthalmologists.

  1. An NGF mimetic, MIM-D3, stimulates conjunctival cell glycoconjugate secretion and demonstrates therapeutic efficacy in a rat model of dry eye.

    PubMed

    Jain, Pooja; Li, Ruihong; Lama, Teresa; Saragovi, H Uri; Cumberlidge, Garth; Meerovitch, Karen

    2011-10-01

    The aim of this study was to evaluate the efficacy of MIM-D3, a small molecule nerve growth factor (NGF) peptidomimetic, as a therapeutic agent in rats with scopolamine induced dry eye. NGF plays an important role in ocular surface maintenance and corneal wound healing and was recently shown to have mucin secretagogue activity in conjunctival cells. We investigated whether MIM-D3 increased glycoconjugate secretion in conjunctival cells in vitro and in rat tear fluids in vivo. Primary rat conjunctival cell cultures were treated with increasing concentrations of MIM-D3 and evaluated for glycoconjugate secretion, proliferation and MAPK1/2 activation. Glycoconjugates were quantitated in tear fluids from normal rats treated topically with increasing doses of MIM-D3 (0.4%, 1% and 2.5%). Dry eye was induced in rats by subcutaneous scopolamine treatment, administered by surgically implanted osmotic pumps for 14 or 28 days. Aqueous tear production, tear clearance, fluorescein corneal staining and tear break-up time (tBUT) were evaluated. Glycoconjugates and NGF were quantitated in the tear fluids by enzyme-linked lectin assay (ELLA) and enzyme-linked immunosorbant assay (ELISA), respectively. We found that 50 μM MIM-D3 statistically significantly induced a 1.3-fold increase in glycoconjugate secretion and a 2.3-fold increase in MAPK1/2 activation without increasing proliferation from conjunctival cell cultures. Application of 2.5% MIM-D3 in normal rat eyes statistically significantly increased tear glycoconjugate concentration by 2.3-fold. In the experimental dry eye model, application of 1% MIM-D3 to rat eyes for either 1 or 17 consecutive days, followed by 1 week of no dosing produced a statistically significant decrease in corneal staining (p < 0.001), a slight increase in tBUT, and increases in tear glycoconjugates (p < 0.05) compared to vehicle. Scopolamine treatment also caused a statistically significant increase of endogenous NGF in tears (p < 0.005). We concluded that the increase in glycoconjugate concentration by the 1% MIM-D3 dose may have improved the quality and stability of the tear film, and thereby improved healing on the ocular surface in dry eye. Therefore, MIM-D3 may have therapeutic potential as a topical agent for the treatment of dry eye. Copyright © 2011 Elsevier Ltd. All rights reserved.

  2. Organization of Lipids in the Tear Film: A Molecular-Level View

    PubMed Central

    Wizert, Alicja; Iskander, D. Robert; Cwiklik, Lukasz

    2014-01-01

    Biophysical properties of the tear film lipid layer are studied at the molecular level employing coarse grain molecular dynamics (MD) simulations with a realistic model of the human tear film. In this model, polar lipids are chosen to reflect the current knowledge on the lipidome of the tear film whereas typical Meibomian-origin lipids are included in the thick non-polar lipids subphase. Simulation conditions mimic those experienced by the real human tear film during blinks. Namely, thermodynamic equilibrium simulations at different lateral compressions are performed to model varying surface pressure, and the dynamics of the system during a blink is studied by non-equilibrium MD simulations. Polar lipids separate their non-polar counterparts from water by forming a monomolecular layer whereas the non-polar molecules establish a thick outermost lipid layer. Under lateral compression, the polar layer undulates and a sorting of polar lipids occurs. Moreover, formation of three-dimensional aggregates of polar lipids in both non-polar and water subphases is observed. We suggest that these three-dimensional structures are abundant under dynamic conditions caused by the action of eye lids and that they act as reservoirs of polar lipids, thus increasing stability of the tear film. PMID:24651175

  3. Extended MHD modeling of nonlinear instabilities in fusion and space plasmas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Germaschewski, Kai

    A number of different sub-projects where pursued within this DOE early career project. The primary focus was on using fully nonlinear, curvilinear, extended MHD simulations of instabilities with applications to fusion and space plasmas. In particular, we performed comprehensive studies of the dynamics of the double tearing mode in different regimes and confi gurations, using Cartesian and cyclindrical geometry and investigating both linear and non-linear dynamics. In addition to traditional extended MHD involving Hall term and electron pressure gradient, we also employed a new multi-fluid moment model, which shows great promise to incorporate kinetic effects, in particular off-diagonal elements ofmore » the pressure tensor, in a fluid model, which is naturally computationally much cheaper than fully kinetic particle or Vlasov simulations. We used our Vlasov code for detailed studies of how weak collisions effect plasma echos. In addition, we have played an important supporting role working with the PPPL theory group around Will Fox and Amitava Bhattacharjee on providing simulation support for HED plasma experiments performed at high-powered laser facilities like OMEGA-EP in Rochester, NY. This project has support a great number of computational advances in our fluid and kinetic plasma models, and has been crucial to winning multiple INCITE computer time awards that supported our computational modeling.« less

  4. Influence of a controlled environment simulating an in-flight airplane cabin on dry eye disease.

    PubMed

    Tesón, Marisa; González-García, María J; López-Miguel, Alberto; Enríquez-de-Salamanca, Amalia; Martín-Montañez, Vicente; Benito, María Jesús; Mateo, María Eugenia; Stern, Michael E; Calonge, Margarita

    2013-03-01

    To evaluate symptoms, signs, and the levels of 16 tears inflammatory mediators of dry eye (DE) patients exposed to an environment simulating an in-flight air cabin in an environmental chamber. Twenty DE patients were exposed to controlled environment simulating an in-flight airplane cabin (simulated in-flight condition [SIC]) of 23°C, 5% relative humidity, localized air flow, and 750 millibars (mb) of barometric pressure. As controls, 15 DE patients were subjected to a simulated standard condition (SSC) of 23°C, 45% relative humidity, and 930 mb. A DE symptoms questionnaire, diagnostic tests, and determination of 16 tear molecules by multiplex bead array were performed before and 2 hours after exposure. After SIC exposure, DE patients became more symptomatic, suffered a significant (P ≤ 0.05) decrease in tear stability (tear break up time) (from 2.18 ± 0.28 to 1.53 ± 0.20), and tear volume (phenol red thread test), and a significant (P ≤ 0.05) increase in corneal staining, both globally (0.50 ± 0.14 before and 1.25 ± 0.19 after) and in each area (Baylor scale). After SSC, DE patients only showed a mild, but significant (P ≤ 0.05), increase in central and inferior corneal staining. Consistently, tear levels of IL-6 and matrix metalloproteinase (MMP)-9 significantly increased and tear epidermal growth factor (EGF) significantly decreased (P ≤ 0.05) only after SIC. The controlled adverse environment conditions in this environmental chamber can simulate the conditions in which DE patients might be exposed during flight. As this clearly impaired their lacrimal functional unit, it would be advisable that DE patients use therapeutic strategies capable of ameliorating these adverse episodes.

  5. Contact Lens Anterior Surface pH

    DTIC Science & Technology

    1991-02-01

    greenhouse effect and contact lenses, in Trans- 4. Nom MS: Tear fluid pH in normals, contact lens wearers, actions of the British Contact Lens...Invest 3. Fullard R), Carney LG: Diurnal variation in human tear en- Op/hdanmol Vis Sci 1978;17:810-813. ymes. Exp Eye Res 1984;38:15-26. 20. Efron N: The

  6. Optimization and validation of an existing, surgical and robust dry eye rat model for the evaluation of therapeutic compounds.

    PubMed

    Joossen, Cedric; Lanckacker, Ellen; Zakaria, Nadia; Koppen, Carina; Joossens, Jurgen; Cools, Nathalie; De Meester, Ingrid; Lambeir, Anne-Marie; Delputte, Peter; Maes, Louis; Cos, Paul

    2016-05-01

    The aim of this research was to optimize and validate an animal model for dry eye, adopting clinically relevant evaluation parameters. Dry eye was induced in female Wistar rats by surgical removal of the exorbital lacrimal gland. The clinical manifestations of dry eye were evaluated by tear volume measurements, corneal fluorescein staining, cytokine measurements in tear fluid, MMP-9 mRNA expression and CD3(+) cell infiltration in the conjunctiva. The animal model was validated by treatment with Restasis(®) (4 weeks) and commercial dexamethasone eye drops (2 weeks). Removal of the exorbital lacrimal gland resulted in 50% decrease in tear volume and a gradual increase in corneal fluorescein staining. Elevated levels of TNF-α and IL-1α have been registered in tear fluid together with an increase in CD3(+) cells in the palpebral conjunctiva when compared to control animals. Additionally, an increase in MMP-9 mRNA expression was recorded in conjunctival tissue. Reference treatment with Restasis(®) and dexamethasone eye drops had a positive effect on all evaluation parameters, except on tear volume. This rat dry eye model was validated extensively and judged appropriate for the evaluation of novel compounds and therapeutic preparations for dry eye disease. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. Trace elements and diabetes: Assessment of levels in tears and serum.

    PubMed

    Cancarini, A; Fostinelli, J; Napoli, L; Gilberti, M E; Apostoli, P; Semeraro, F

    2017-01-01

    Tear film is critical for the well-being and homeostasis of the ocular surface. Although the composition of the tear film is well known, the composition of metallic elements have yet to be analysed. Despite trace elements metabolism has been reported to play a role in the pathogenesis of diabetes mellitus, a metabolic disease that affects several aspects of homeostasis, little is known in the literature regarding concentration and possible variation of metallic elements in tear film. We studied the concentrations of several essential and non-essential metallic elements in the tear fluid and serum of patients with type II diabetes mellitus and a group of non-diabetic controls. Serum and tear fluid were collected from 97 patients: 47 type II diabetic patients and 50 non-diabetic controls. Regarding tear film, there were statistically significant differences in Zinc, Chrome, Cobalt, Manganese, Barium, and Lead between groups; the values of all metallic elements were found to be statistically significant higher in patients with mellitus type II diabetes. Regarding serum values there was a statistically significant difference in Chrome, Cobalt, and Selenium values; the concentrations of Chrome and Cobalt were higher in the control group, while Selenium concentration was higher in diabetic patients. In patients with type II diabetes, metal elements with higher concentrations in tears compared to serum were: Lead, Barium, Manganese, Cobalt, and Chrome. In the control group, the metal elements with the highest concentration in tear film compared to serum were Chrome, Manganese, Barium, and Lead. In this study, we attempted to evaluate the possible effect of a disease, such as diabetes, on the metabolism of metallic elements. Although our evidence was very interesting, it is probably limited in its accuracy due to the fact that individuals in the control group harboured ocular pathologies. This work lays the foundation for future studies. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. Mucin-type O-glycans in Tears of Normal Subjects and Patients with Non-Sjögren’s Dry Eye

    PubMed Central

    Guzman-Aranguez, Ana; Mantelli, Flavio; Argüeso, Pablo

    2009-01-01

    Purpose O-linked carbohydrates (O-glycans) contribute to the hydrophilic character of mucins in mucosal tissues. This study aimed to identify the repertoire of O-glycans in the tear film, and the glycosyltransferases associated with their biosynthesis, in normal subjects and patients with non-Sjögren’s dry eye. Methods Human tear fluid was collected from the inferior conjunctival fornix. O-glycans were released by hydrazinolysis, labeled with 2-aminobenzamide, and analyzed by fluorometric, high-performance liquid chromatography (HPLC) coupled with exoglycosidase digestions. O-glycan structures identified in tears were related to potential biosynthetic pathways in human conjunctival epithelium using a glycogene microarray database. Lectin-binding analyses were performed using agglutinins from Arachis hypogaea, Maackia amurensis, and Sambucus nigra. Results The O-glycan profile of human tears consisted primarily of core 1 (Galβ1-3GalNAcα1-Ser/Thr)-based structures. Mono-sialyl O-glycans represented approximately 66% of the glycan pool, being α2-6-sialyl core 1 the predominant O-glycan structure in human tears (48%). Four families of glycosyltranferases potentially related to the biosynthesis of these structures were identified in human conjunctiva. These included thirteen polypeptide-GalNAc-transferases (GALNT), the core 1 β-3-galactosyltransferase (T-synthase), three α2-6-sialyltransferases (ST6GalNAc), and two α2-3-sialyltransferases (ST3Gal). No significant differences in total amount of O-glycans were detected between tears of normal subjects and dry eye patients, by HPLC and lectin blot. Likewise, no differences in glycosyltransferase expression were found by glycogene microarray. Conclusions This study identifies the most common mucin-type O-glycans in human tears and their expected biosynthetic pathways in ocular surface epithelia. Patients with non-Sjögren’s dry eye show no alterations in composition and amount of O-glycans in the tear fluid. PMID:19407012

  9. Pseudomonas aeruginosa Survival at Posterior Contact Lens Surfaces after Daily Wear

    PubMed Central

    Wu, Yvonne T.; Zhu, Lucia S.; Tam, K. P. Connie; Evans, David J.; Fleiszig, Suzanne M. J.

    2015-01-01

    Purpose Pseudomonas aeruginosa keratitis is a sight-threatening complication of contact lens wear, yet mechanisms by which lenses predispose to infection remain unclear. Here, we tested the hypothesis that tear fluid at the posterior contact lens surface can lose antimicrobial activity over time during lens wear. Methods Daily disposable lenses were worn for 1, 2, 4, 6 or 8 h immediately after removal from their packaging, or after presoaking in sterile saline for 2 days to remove packaging solution. Unworn lenses were also tested, some coated in tears “aged” in vitro for 1 or 8 h. Lenses were placed anterior surface down into tryptic soy agar cradles containing gentamicin (100µg/ml) to kill bacteria already on the lens, and posterior surfaces inoculated with gentamicin-resistant P. aeruginosa for 3 h. Surviving bacteria were enumerated by viable counts of lens homogenates. Results Posterior surfaces of lenses worn by patients for 8 h supported more P. aeruginosa growth than lenses worn for only 1 h, if lenses were presoaked prior to wear (~ 2.4-fold, p = 0.01). This increase was offset if lenses were not presoaked to remove packaging solution (p = 0.04 at 2 h and 4 h). Irrespective of presoaking, lenses worn for 8 h showed more growth on their posterior surface than unworn lenses coated with tear fluid that was “aged” for 8 h vitro (~8.6-fold, presoaked, p = 0.003: ~ 5.4-fold from packaging solution, p = 0.004). Indeed, in vitro incubation did not impact tear antimicrobial activity. Conclusions This study shows that post lens tear fluid can lose antimicrobial activity over time during contact lens wear, supporting the idea that efficient tear exchange under a lens is critical for homeostasis. Additional studies are needed to determine applicability to other lens types, wearing modalities, and relevance to contact lens-related infections. PMID:25955639

  10. 21 CFR 349.3 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... of acids or bases from such sources as drugs, body fluids, tears, etc. (d) Demulcent. An agent... membrane surfaces and relieve dryness and irritation. (e) Emollient. An agent, usually a fat or oil, which... present in body tissues and fluids, so that water is drawn from the body tissues and fluids across...

  11. 21 CFR 349.3 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... of acids or bases from such sources as drugs, body fluids, tears, etc. (d) Demulcent. An agent... membrane surfaces and relieve dryness and irritation. (e) Emollient. An agent, usually a fat or oil, which... present in body tissues and fluids, so that water is drawn from the body tissues and fluids across...

  12. 21 CFR 349.3 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... of acids or bases from such sources as drugs, body fluids, tears, etc. (d) Demulcent. An agent... membrane surfaces and relieve dryness and irritation. (e) Emollient. An agent, usually a fat or oil, which... present in body tissues and fluids, so that water is drawn from the body tissues and fluids across...

  13. Interaction of lysozyme with a tear film lipid layer model: A molecular dynamics simulation study.

    PubMed

    Wizert, Alicja; Iskander, D Robert; Cwiklik, Lukasz

    2017-12-01

    The tear film is a thin multilayered structure covering the cornea. Its outermost layer is a lipid film underneath of which resides on an aqueous layer. This tear film lipid layer (TFLL) is itself a complex structure, formed by both polar and nonpolar lipids. It was recently suggested that due to tear film dynamics, TFLL contains inhomogeneities in the form of polar lipid aggregates. The aqueous phase of tear film contains lachrymal-origin proteins, whereby lysozyme is the most abundant. These proteins can alter TFLL properties, mainly by reducing its surface tension. However, a detailed nature of protein-lipid interactions in tear film is not known. We investigate the interactions of lysozyme with TFLL in molecular details by employing coarse-grained molecular dynamics simulations. We demonstrate that lysozyme, due to lateral restructuring of TFLL, is able to penetrate the tear lipid film embedded in inverse micellar aggregates. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Tear Fluid SIgA as a Noninvasive Biomarker of Mucosal Immunity and Common Cold Risk.

    PubMed

    Hanstock, Helen G; Walsh, Neil P; Edwards, Jason P; Fortes, Matthew B; Cosby, Sara L; Nugent, Aaron; Curran, Tanya; Coyle, Peter V; Ward, Mark D; Yong, Xin Hui Aw

    2016-03-01

    Research has not convincingly demonstrated the utility of saliva secretory immunoglobulin-A (SIgA) as a biomarker of upper respiratory tract infection (URTI) risk, and disagreement exists about the influence of heavy exercise ("open-window theory") and dehydration on saliva SIgA. Prompted by the search for viable alternatives, we compared the utility of tear and saliva SIgA to predict URTI prospectively (study 1) and assessed the influence of exercise (study 2) and dehydration (study 3) using a repeated-measures crossover design. In study 1, 40 subjects were recruited during the common-cold season. Subjects provided tear and saliva samples weekly and recorded upper respiratory symptoms (URS) daily for 3 wk. Real-time PCR confirmed common-cold pathogens in 9 of 11 subjects reporting URS (82%). Predictive utility of tear and saliva SIgA was explored by comparing healthy samples with those collected during the week before URS. In study 2, 13 subjects performed a 2-h run at 65% V˙O2peak. In study 3, 13 subjects performed exercise heat stress to 3% body mass loss followed by overnight fluid restriction. Tear SIgA concentration and secretion rate were 48% and 51% lower, respectively, during URTI and 34% and 46% lower the week before URS (P < 0.05), but saliva SIgA remained unchanged. The risk of URS the following week increased ninefold (95% confidence interval, 1.7-48) when the tear SIgA secretion rate was <5.5 μg·min(-1) and sixfold (95% confidence interval, 1.2-29) when the tear SIgA secretion rate decreased >30%. Tear SIgA secretion rate >5.5 μg·min(-1) or no decrease of >30% predicted subjects free of URS in >80% of cases. Tear SIgA concentration decreased after exercise (-57%, P < 0.05) in line with the "open-window theory" but was unaffected by dehydration. Saliva flow rate decreased and saliva SIgA concentration increased after exercise and during dehydration (P < 0.05). Tear SIgA has utility as a noninvasive biomarker of mucosal immunity and common-cold risk.

  15. Duplex Tear Film Evaporation Analysis.

    PubMed

    Stapf, M R; Braun, R J; King-Smith, P E

    2017-12-01

    Tear film thinning, hyperosmolarity, and breakup can cause irritation and damage to the human eye, and these form an area of active investigation for dry eye syndrome research. Recent research demonstrates that deficiencies in the lipid layer may cause locally increased evaporation, inducing conditions for breakup. In this paper, we explore the conditions for tear film breakup by considering a model for tear film dynamics with two mobile fluid layers, the aqueous and lipid layers. In addition, we include the effects of osmosis, evaporation as modified by the lipid, and the polar portion of the lipid layer. We solve the system numerically for reasonable parameter values and initial conditions and analyze how shifts in these cause changes to the system's dynamics.

  16. Formation, spin-up, and stability of field-reversed configurations

    DOE PAGES

    Omelchenko, Yuri A.

    2015-08-24

    Formation, spontaneous spin-up and stability of theta-pinch formed field-reversed configurations are studied self-consistently in three dimensions with a multiscale hybrid model that treats all plasma ions as full-orbit collisional macro-particles and the electrons as a massless quasineutral fluid. The end-to-end hybrid simulations for the first time reveal poloidal profiles of implosion-driven fast toroidal plasma rotation and demonstrate three well-known discharge regimes as a function of experimental parameters: the decaying stable configuration, the tilt unstable configuration and the nonlinear evolution of a fast growing tearing mode.

  17. A mathematical model of the structure and evolution of small-scale discrete auroral arcs

    NASA Technical Reports Server (NTRS)

    Seyler, Charles E.

    1990-01-01

    A three-dimensional fluid model for the structure and evolution of small-scale discrete auroral arcs originating from Alfven waves is developed and used to study the nonlinear macroscopic plasma dynamics of these auroral arcs. The results of simulations show that stationary auroral arcs can be unstable to a collisionless tearing mode which may be responsible for the observed transverse structuring in the form of folds and curls. At late times, the plasma becomes turbulent having transverse electric field power spectra that tend toward a universal k exp -5/3 spectral form.

  18. Rotator cuff repair with all-suture anchors: a midterm magnetic resonance imaging evaluation of repair integrity and cyst formation.

    PubMed

    Van der Bracht, Hans; Van den Langenbergh, Tom; Pouillon, Marc; Verhasselt, Skrallan; Verniers, Philippe; Stoffelen, Danny

    2018-05-22

    This study investigated the feasibility and safety of all-suture anchors in arthroscopic rotator cuff repair. All patients were diagnosed with a rotator cuff tear by ultrasound or magnetic resonance imaging (MRI). Patients with partial tears, massive tears, subscapularis tears, or previous shoulder surgery, were excluded. MRI and clinical outcome were investigated in all patients at 1.58 years (range, 1.0-2.0 years) after rotator cuff repair with all-suture anchors (prospective case series). Integrity of the cuff repair, cyst formation (encapsulated fluid signal around the anchor), ingrowth of the bone into the anchor, and integrity of the bone tunnel border were evaluated for 47 anchors. Clinical results were evaluated using the Constant-Murley score. An MRI evaluation was performed in 20 patients at 1.58 years (range, 1.0-2.0 years) after rotator cuff repair with all-suture anchors. MRI evaluation showed a very small rim of fluid around 10% of the anchors. None of the anchors showed cyst formation with fluid diameter more than twice the anchor diameter. In approximately 90% of the anchors, no fluid could be detected between the anchors and the edge of the bony tunnel. Full rotator cuff integrity was seen in 19 patients. Only 1 patient sustained a retear. Clinical results comparable with an arthroscopic rotator cuff repair using classic anchors were seen. This prospective clinical cohort study shows promising early radiographic and clinical results after arthroscopic rotator cuff repair using all-suture anchors. Copyright © 2018 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  19. Comparison of low-abundance biomarker levels in capillary-collected nonstimulated tears and washout tears of aqueous-deficient and normal patients.

    PubMed

    Guyette, Nicole; Williams, Larezia; Tran, My-Tho; Than, Tammy; Bradley, John; Kehinde, Lucy; Edwards, Clara; Beasley, Mark; Fullard, Roderick

    2013-05-01

    Low tear volume limits the use of nonstimulated (NS) microcapillary tear collection in aqueous-deficient (AD) patients. Adding a small amount of "washout" fluid to the eye prior to tear collection is a potentially viable alternative method for abundant proteins, but is relatively untested for low-abundance biomarkers. This study determined the feasibility of the washout (WO) method as an NS alternative for low-abundance biomarkers. NS and WO biomarker profiles were compared between AD patients and non-AD controls to determine if the two methods identify the same intergroup differences. Matching NS and WO tears were collected from 48 patients by micropipette, the WO sample after instillation of 10 μL saline. Tear cytokine levels were measured by 27-Plex Bio-Rad assay. Bland-Altman analyses for each biomarker determined the agreement between tear sample types. Patients were grouped as AD or non-AD based on Schirmer score to determine if NS profile between-group differences were preserved in WO tears. Bland-Altman plots showed good biomarker level agreement between NS and WO tears for most cytokines. Five biomarkers, among those most often cited as differing in AD dry eye, differed significantly between non-AD and AD groups in both tear types. Additional biomarker differences were seen in NS tears only. The WO tear collection method is a viable alternative to NS tears for many low-abundance biomarkers and is able to replicate major NS tear differences between dry eye groups. More subtle intergroup differences are lost in WO samples because of reduced statistical power.

  20. Interferometer for measuring dynamic corneal topography

    NASA Astrophysics Data System (ADS)

    Micali, Jason Daniel

    The cornea is the anterior most surface of the eye and plays a critical role in vision. A thin fluid layer, the tear film, coats the outer surface of the cornea and serves to protect, nourish, and lubricate the cornea. At the same time, the tear film is responsible for creating a smooth continuous surface where the majority of refraction takes place in the eye. A significant component of vision quality is determined by the shape of the cornea and stability of the tear film. It is desirable to possess an instrument that can measure the corneal shape and tear film surface with the same accuracy and resolution that is currently performed on common optical elements. A dual interferometer system for measuring the dynamic corneal topography is designed, built, and verified. The completed system is validated by testing on human subjects. The system consists of two co-aligned polarization splitting Twyman-Green interferometers designed to measure phase instantaneously. The primary interferometer measures the surface of the tear film while the secondary interferometer simultaneously tracks the absolute position of the cornea. Eye motion, ocular variation, and a dynamic tear film surface will result in a non-null configuration of the surface with respect to the interferometer system. A non-null test results in significant interferometer induced errors that add to the measured phase. New algorithms are developed to recover the absolute surface topography of the tear film and corneal surface from the simultaneous interferometer measurements. The results are high-resolution and high-accuracy surface topography measurements of the in vivo cornea that are captured at standard camera frame rates. This dissertation will cover the development and construction of an interferometer system for measuring the dynamic corneal topography of the human eye. The discussion starts with the completion of an interferometer for measuring the tear film. The tear film interferometer is part of an ongoing research project that has spanned multiple dissertations. For this research, the instrument was tested on human subjects and resulted in refinements to the interferometer design. The final configuration of the tear film interferometer and results from human subjects testing are presented. Feedback from this instrument was used to support the development and construction of the interferometric corneal topographer system. A calibration is performed on the instrument, and then verified against simulated eye surfaces. Finally, the instrument is validated by testing on human subjects. The result is an interferometer system that can non-invasively measure the dynamic corneal topography with greater accuracy and resolution than existing technologies.

  1. If You Have Chronic Hepatitis B Virus (HBV) Infection

    MedlinePlus

    ... can further damage your liver.  Don’t eat raw oysters. Raw oysters may carry the bacteria Vibrio vulnificus which ... fluids, including tears, sweat, urine, feces, and breast milk, these fluids have not been associated with known ...

  2. Pedestal-to-Wall 3D Fluid Transport Simulations on DIII-D

    DOE PAGES

    Lore, Jeremy D.; Wolfmeister, Alexis Briesemeister; Ferraro, Nathaniel M.; ...

    2017-03-30

    The 3D fluid-plasma edge transport code EMC3-EIRENE is used to test several magnetic field models with and without plasma response against DIII-D experimental data for even and odd-parity n=3 magnetic field perturbations. The field models include ideal and extended MHD equilibria, and the vacuum approximation. Plasma response is required to reduce the stochasticity in the pedestal region for even-parity fields, however too much screening suppresses the measured splitting of the downstream T e profile. Odd-parity perturbations result in weak tearing and only small additional peaks in the downstream measurements. In this case plasma response is required to increase the sizemore » of the lobe structure. Finally, no single model is able to simultaneously reproduce the upstream and downstream characteristics for both odd and even-parity perturbations.« less

  3. Coupled thermal stress simulations of ductile tearing

    DOE PAGES

    Neilsen, Michael K.; Dion, Kristin

    2016-03-01

    Predictions for ductile tearing of a geometrically complex Ti-6Al-4V plate were generated using a Unified Creep Plasticity Damage model in fully coupled thermal stress simulations. Uniaxial tension and butterfly shear tests performed at displacement rates of 0.0254 and 25.4 mm/s were also simulated. Results from these simulations revealed that the material temperature increase due to plastic work can have a dramatic effect on material ductility predictions in materials that exhibit little strain hardening. Furthermore, this occurs because the temperature increase causes the apparent hardening of the material to decrease which leads to the initiation of deformation localization and subsequent ductilemore » tearing earlier in the loading process.« less

  4. Altered tear inflammatory profile in Indian keratoconus patients - The 2015 Col Rangachari Award paper

    PubMed Central

    Shetty, Rohit; Deshmukh, Rashmi; Ghosh, Arkasubhra; Sethu, Swaminathan; Jayadev, Chaitra

    2017-01-01

    Purpose: Conventionally, keratoconus (KC) has been considered a noninflammatory corneal ectatic disorder. Recent evidence suggests a possible role of inflammation in the pathogenesis of KC. Hence, we analyzed the levels of inflammatory factors in the tear fluid of Indian KC patients. Methods: Tear fluid samples were collected from age- and sex-matched healthy controls and KC patients (with different grades). The levels of the inflammatory factors in tears were analyzed using cytometric bead array (Human Soluble Protein Flex Set System, BD Biosciences) for levels of interleukin-1α (IL-1α), IL-1β, IL-2, IL-4, IL-5, IL-6, IL-8, IL-9, IL-10, IL-12p70, IL-23p40, IL-13, IL-17A, IL-17F, IL-21, interferon-α (IFNα), IFNγ, tumor necrosis factor-α, CCL2/monocyte chemotactic protein-1, CCL4/macrophage inflammatory protein-1β (MIP-1β), MIP-1α, CCL5/RANTES, CXCL10/IP10, ICAM1, CD62E, vascular endothelial growth factor and transforming growth factor β. Results: An increase in Kmax and Kmean, and a decrease in central corneal thickness was observed with increasing grades of KC. Tear analysis showed that most of the tear soluble factors, including cytokines, chemokines, growth factors and cell adhesion molecules were significantly elevated in the KC patients compared to the controls. Conclusion: Our findings suggest that inflammatory factors associated with KC may play a role in its pathogenesis. This opens the potential to explore anti-inflammatory strategies to either halt or delay the progression of KC. PMID:29133633

  5. Cerebrospinal fluid leaks following spinal surgery: use of fat grafts for prevention and repair. Technical note.

    PubMed

    Black, Perry

    2002-03-01

    Cerebrospinal fluid (CSF) leaks are relatively common following spinal surgery. A midline dural tear in the spine is readily repaired by direct application of sutures; however, far-lateral or ventral dural tears are problematic. Fat is an ideal sealant because it is impermeable to water. In this paper the author reports his experience with using fat grafts for the prevention or repair of CSF leaks and proposes a technique in which a large sheet of fat, harvested from the patient's subcutaneous layer, is used to cover not only the dural tear(s) but all of the exposed dura and is tucked into the lateral recess. This procedure prevents CSF from seeping around the fat, which may be tacked to the dura with a few sutures. Fibrin glue is spread on the surface of the fat and is further covered with Surgicel or Gelfoam. For ventral dural tears (associated with procedures in which disc material is excised), fat is packed into the disc space to seal off the ventral dural leak. Dural suture lines following spinal intradural exploration are prophylatically protected from CSF leakage in the same manner. With one exception, 27 dural tears noted during 1650 spinal procedures were successfully repaired using this technique. There was one case of postoperative CSF leakage in 140 cases in which intradural exploration for tumor or other lesions was undertaken. Both postoperative CSF leaks were controlled by applying additional skin sutures. The use of a fat graft is recommended as a rapid, effective means of prevention and repair of CSF leaks following spinal surgery.

  6. Extreme Facial Expressions Classification Based on Reality Parameters

    NASA Astrophysics Data System (ADS)

    Rahim, Mohd Shafry Mohd; Rad, Abdolvahab Ehsani; Rehman, Amjad; Altameem, Ayman

    2014-09-01

    Extreme expressions are really type of emotional expressions that are basically stimulated through the strong emotion. An example of those extreme expression is satisfied through tears. So to be able to provide these types of features; additional elements like fluid mechanism (particle system) plus some of physics techniques like (SPH) are introduced. The fusion of facile animation with SPH exhibits promising results. Accordingly, proposed fluid technique using facial animation is the real tenor for this research to get the complex expression, like laugh, smile, cry (tears emergence) or the sadness until cry strongly, as an extreme expression classification that's happens on the human face in some cases.

  7. Relevance of Lipid-Based Products in the Management of Dry Eye Disease.

    PubMed

    Garrigue, Jean-Sébastien; Amrane, Mourad; Faure, Marie-Odile; Holopainen, Juha M; Tong, Louis

    2017-11-01

    Components of the ocular surface synergistically contribute to maintaining and protecting a smooth refractive layer to facilitate the optimal transmission of light. At the air-water interface, the tear film lipid layer (TFLL), a mixture of lipids and proteins, plays a key role in tear surface tension and is important for the physiological hydration of the ocular surface and for ocular homeostasis. Alterations in tear fluid rheology, differences in lipid composition, or downregulation of specific tear proteins are found in most types of ocular surface disease, including dry eye disease (DED). Artificial tears have long been a first line of treatment in DED and aim to replace or supplement tears. More recently, lipid-containing eye drops have been developed to more closely mimic the combination of aqueous and lipid layers of the TFLL. Over the last 2 decades, our understanding of the nature and importance of lipids in the tear film in health and disease has increased substantially. The aim of this article is to provide a brief overview of our current understanding of tear film properties and review the effectiveness of lipid-based products in the treatment of DED. Liposome lid sprays, emulsion eye drops, and other lipid-containing formulations are discussed.

  8. Mechanical risk of rotator cuff repair failure during passive movements: A simulation-based study.

    PubMed

    Haering, Diane; Blache, Yoann; Raison, Maxime; Begon, Mickael

    2015-12-01

    Despite improvements in rotator cuff surgery techniques, re-tear rate remains above 20% and increases with tear severity. Mechanical stresses to failure of repaired tendons have been reported. While optimal immobilization postures were proposed to minimize this stress, post-operative rehabilitation protocols have never been assessed with respect to these values. Purpose was to use musculoskeletal simulation to predict when the stress in repaired tendons exceeds safety limits during passive movements. Hence, guidelines could be provided towards safer post-operative exercises. Sixteen healthy participants volunteered in passive three-dimensional shoulder range-of-motion and passive rehabilitation exercises assessment. Stress in all rotator cuff tendons was predicted during each movement by means of a musculoskeletal model using simulations with different type and size of tears. Safety stress thresholds were defined based on repaired tendon loads to failure reported in the literature and used to discriminate safe from unsafe ranges-of-motion. Increased tear size and multiple tendons tear decreased safe range-of-motion. Mostly, glenohumeral elevations below 38°, above 65°, or performed with the arm held in internal rotation cause excessive stresses in most types and sizes of injury during abduction, scaption or flexion. Larger safe amplitudes of elevation are found in scapular plane for supraspinatus alone, supraspinatus plus infraspinatus, and supraspinatus plus subscapularis tears. This study reinforces that passive early rehabilitation exercises could contribute to re-tear due to excessive stresses. Recommendations arising from this study, for instance to keep the arm externally rotated during elevation in case of supraspinatus or supraspinatus plus infraspinatus tear, could help prevent re-tear. Crown Copyright © 2015. Published by Elsevier Ltd. All rights reserved.

  9. Tear Film Dynamics: the roles of complex structure and rheology

    NASA Astrophysics Data System (ADS)

    Dey, Mohar; Feng, James; Vivek, Atul S.; Dixit, Harish N.; Richhariya, Ashutosh

    2016-11-01

    Ocular surface infections such as microbial and fungal keratitis are among leading causes of blindness in the world. A thorough understanding of the pre-corneal tear film dynamics is essential to comprehend the role of various tear layer components in the escalation of such ocular infections. The pre-corneal tear film comprises of three layers of complex fluids, viz. the innermost mucin layer, a hydrophilic protective cover over the sensitive corneal epithelium, the intermediate aqueous layer that forms the bulk of the tear film and is often embedded with large number of bio-polymers either in the form of soluble mucins or pathogens, and finally the outermost lipid layer that stabilizes the film by decreasing the air/tear film interfacial tension. We have developed a comprehensive mathematical model to describe such a film by incorporating the effects of the non-uniform mucin distribution along with the complex rheology of the aqueous layer with/without pathogens, Marangoni effects from the lipid layer and the slip effects at the base of the tear film. A detailed linear stability analysis and a fully non-linear solution determine the break up time (BUT) of such a tear film. We also probe the role of the various components of the pre-corneal tear film in the dynamics of rupture.

  10. Full-thickness tears of the supraspinatus tendon: A three-dimensional finite element analysis.

    PubMed

    Quental, C; Folgado, J; Monteiro, J; Sarmento, M

    2016-12-08

    Knowledge regarding the likelihood of propagation of supraspinatus tears is important to allow an early identification of patients for whom a conservative treatment is more likely to fail, and consequently, to improve their clinical outcome. The aim of this study was to investigate the potential for propagation of posterior, central, and anterior full-thickness tears of different sizes using the finite element method. A three-dimensional finite element model of the supraspinatus tendon was generated from the Visible Human Project data. The mechanical behaviour of the tendon was fitted from experimental data using a transversely isotropic hyperelastic constitutive model. The full-thickness tears were simulated at the supraspinatus tendon insertion by decreasing the interface area. Tear sizes from 10% to 90%, in 10% increments, of the anteroposterior length of the supraspinatus footprint were considered in the posterior, central, and anterior regions of the tendon. For each tear, three finite element analyses were performed for a supraspinatus force of 100N, 200N, and 400N. Considering a correlation between tendon strain and the risk of tear propagation, the simulated tears were compared qualitatively and quantitatively by evaluating the volume of tendon for which a maximum strain criterion was not satisfied. The finite element analyses showed a significant impact of tear size and location not only on the magnitude, but also on the patterns of the maximum principal strains. The mechanical outcome of the anterior full-thickness tears was consistently, and significantly, more severe than that of the central or posterior full-thickness tears, which suggests that the anterior tears are at greater risk of propagating than the central or posterior tears. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Resistive magnetohydrodynamics with toroidal rotation in toroidal plasmas

    NASA Astrophysics Data System (ADS)

    Cao, Jintao; Cai, Huishan

    2018-01-01

    Toroidal rotation has always existed in tokamak plasmas, and its Mach number can reach unity during neutral beam injection. Toroidal rotation can affect plasma equilibrium and magnetohydrodynamic instabilities significantly. Based on linearized equations including the toroidal rotation effect, the toroidal model derived by Glasser et al. [Phys. Fluids 18, 875 (1975)] is extended to include this effect, and a set of resistive equations including the toroidal rotation effect in the axi-symmetry toroidal geometry is derived. Based on these derived equations, the effect of toroidal rotation on tearing modes is considered, and the growth rate of tearing modes is obtained analytically. It is shown that the effect of toroidal rotation on tearing modes depends on both the direction of toroidal rotation flow and the sign of toroidal rotation flow shear. When they have the same sign, they play a role in stabilizing tearing modes, while when they have opposite signs, they have a destabilizing effect on tearing modes.

  12. Simulation of the hydrodynamic conditions of the eye to better reproduce the drug release from hydrogel contact lenses: experiments and modeling.

    PubMed

    Pimenta, A F R; Valente, A; Pereira, J M C; Pereira, J C F; Filipe, H P; Mata, J L G; Colaço, R; Saramago, B; Serro, A P

    2016-12-01

    Currently, most in vitro drug release studies for ophthalmic applications are carried out in static sink conditions. Although this procedure is simple and useful to make comparative studies, it does not describe adequately the drug release kinetics in the eye, considering the small tear volume and flow rates found in vivo. In this work, a microfluidic cell was designed and used to mimic the continuous, volumetric flow rate of tear fluid and its low volume. The suitable operation of the cell, in terms of uniformity and symmetry of flux, was proved using a numerical model based in the Navier-Stokes and continuity equations. The release profile of a model system (a hydroxyethyl methacrylate-based hydrogel (HEMA/PVP) for soft contact lenses (SCLs) loaded with diclofenac) obtained with the microfluidic cell was compared with that obtained in static conditions, showing that the kinetics of release in dynamic conditions is slower. The application of the numerical model demonstrated that the designed cell can be used to simulate the drug release in the whole range of the human eye tear film volume and allowed to estimate the drug concentration in the volume of liquid in direct contact with the hydrogel. The knowledge of this concentration, which is significantly different from that measured in the experimental tests during the first hours of release, is critical to predict the toxicity of the drug release system and its in vivo efficacy. In conclusion, the use of the microfluidic cell in conjunction with the numerical model shall be a valuable tool to design and optimize new therapeutic drug-loaded SCLs.

  13. Pilot Study on the Investigation of Tear Fluid Biomarkers as an Indicator of Ocular, Neurological, and Immunological Health in Astronauts

    NASA Technical Reports Server (NTRS)

    Morton, Stephen; Crucian, Brian; Hagan, Suzanne; Satyamitra, Merriline; Daily, Anna

    2018-01-01

    The purpose of this pilot study is to investigate the collection, preparation, and analysis of tear biomarkers as a means of assessing ocular, neurological, and immunological health. At present, no published data exists on the cytokine profiles of tears from astronauts exposed to long periods of microgravity and space irradiations. In addition, no published data exist on cytokine (biomarker) profiles of tears that have been collected from irradiated non-human biological systems (primates and other animal models). A goal for the proposed pilot study is to discover novel tear biomarkers which can help inform researchers, clinicians, epidemiologist and healthcare providers about the health status of a living biological system, as well as informing them when a disease state is triggered. This would be done via analysis of the onset of expression of pro-inflammatory cytokines, leading up to the full progression of a disease (i.e. cancer, loss of vision, radiation-induced oxidative stress, cardiovascular disorders, fibrosis in major organs, bone loss). Another goal of this pilot study is to investigate the state of disease against proposed medical countermeasures, in order to determine whether the countermeasures are efficacious in preventing or mitigating these injuries. An example of an up and coming tear biomarker technology, Ascendant Dx, a clinical stage diagnostic company, is developing a screening test to detect breast cancer using proteins from tears. The team utilized Liquid Chromatography -Mass Spectrometry with Mass analysis (LC MS/MS) as a discovery platform followed by validation with ELISA to come up with a panel of protein biomarkers that can differentiate breast cancer samples from control ("cancer free") samples with results far surpassing the results of imaging techniques in use today. Continued research into additional proteins is underway to increase the sensitivity and specificity of the test and development efforts are on the way to transfer the test onto a fast, accurate and inexpensive point of care platform. In conclusion, the expected results from this proposed pilot study are to: a) establish an SOP for retrieving/storing/transporting tear fluid samples from multicentre sites b) establish a normal range for relevant biomarkers in tears; and c) establish a database (biobank) of tears of space naïve versus veteran astronauts, to establish a personal baseline for long-term ocular health monitoring

  14. Cerebrospinal fluid leaks following spinal or posterior fossa surgery: use of fat grafts for prevention and repair.

    PubMed

    Black, P

    2000-01-01

    Cerebrospinal fluid (CSF) leaks are relatively common following spinal or posterior fossa surgery. A midline dural tear in the spine is readily repaired by direct application of a suture. However, far-lateral or ventral dural tears are problematic. Fat is an ideal sealant because it is impermeable to water. In this paper the author reports his experience with using fat grafts for the prevention or repair of CSF leaks and proposes a technique in which a large sheet of fat, harvested from the patient's subcutaneous layer, is used to cover not only the dural tear(s) but all of the exposed dura and is tucked into the lateral recess. This procedure prevents CSF from seeping around the fat, which may be tacked to the dura with a few sutures. Fibrin glue is spread on the surface of the fat and is further covered with Surgicel or Gelfoam. For ventral dural tears (associated with procedures in which disc material is excised), fat is packed into the disc space to seal off the ventral dural leak. Leaks in the posterior fossa are managed similarly to those in the spine. Dural suture lines, following suboccipital or spinal intradural exploration, are prophylactically protected from CSF leakage in the same manner. With one exception, 27 dural tears noted during 1650 spinal procedures were successfully repaired using this technique. There was one case of postoperative CSF leakage in 150 cases in which intradural exploration for tumor or other lesions was undertaken. Both postoperative CSF leaks were controlled by applying additional skin sutures. The use of a fat graft is recommended as a rapid, effective means of prevention and repair of CSF leaks following posterior fossa and spinal surgery.

  15. Vitrectomy and fluid/silicone-oil exchange for giant retinal tears: results at six months.

    PubMed Central

    Leaver, P. K.; Cooling, R. J.; Feretis, E. B.; Lean, J. S.; McLeod, D.

    1984-01-01

    The results of vitrectomy combined with fluid/silicone-oil exchange in 73 eyes with giant retinal tears are reported at six months after surgery. Initial anatomical success was achieved in 71 out of 73 eyes (97%) and, prior to removal of silicone-oil, in 66 out of 73 eyes (90%). In 63 eyes (86%) the retina remained attached six months after surgery. Of these visual acuity was 6/60 or better in 44 (70%). The high proportion of eyes with macular detachment before surgery and the frequency of macular abnormalities are thought to account for reduced vision in many of the anatomically successful cases. PMID:6722076

  16. Dynamics of the aortic arch submitted to a shock loading: Parametric study with fluid-structure models.

    PubMed

    El Baroudi, A; Razafimahery, F; Rakotomanana, L

    2012-01-01

    This work aims to present some fluid-structure models for analyzing the dynamics of the aorta during a brusque loading. Indeed, various lesions may appear at the aortic arch during car crash or other accident such as brusque falling. Aortic stresses evolution are simulated during the shock at the cross section and along the aorta. One hot question was that if a brusque deceleration can generate tissue tearing, or a shock is necessary to provoke such a damage. Different constitutive laws of blood are then tested whereas the aorta is assumed linear and elastic. The overall shock model is inspired from an experimental jig. We show that the viscosity has strong influence on the stress and parietal moments and forces. The nonlinear viscosity has no significant additional effects for healthy aorta, but modifies the stress and parietal loadings for the stenotic aorta.

  17. Patient acceptability of tear collection in the primary healthcare setting.

    PubMed

    Quah, Joanne Hui Min; Tong, Louis; Barbier, Sylvaine

    2014-04-01

    The primary healthcare setting is well placed for health screening. Tear fluid composition gives valuable information about the eye and systemic health, and there is now significant interest in the potential application of tears as a tool for health screening; however, the acceptability of tear collection in the primary healthcare setting as compared with other methods of human sample collection has not been previously addressed. The objective of this study was to evaluate the patient acceptability of tear collection in a primary healthcare setting. This was a cross-sectional study on 383 adult patients seeking primary healthcare, who were not diabetic and were not attending for an eye-related complaint. Tear collection was done using Schirmer strips, and an interviewer-administered questionnaire was conducted to collate information on the pain score (0-10) of the Schirmer tear collection, as well as to score the pain associated with their previous experience of antecubital venous puncture and finger prick test. The pain score for Schirmer tear collection was significantly lower (p < 0.001) than antecubital venous puncture but higher (p < 0.001) than finger prick. The pain scores for all three procedures were significantly higher in participants of younger age, female gender, and higher education level. Among the participants, 70% did not mind their tears being collected to screen for eye problems, whereas only 38% did not mind this procedure being performed for general health screening. Nevertheless, 69% of the participants preferred tear to urine collection, and 74% of participants preferred tear to blood collection. Tear collection using Schirmer strips is a highly acceptable form of investigation that has the potential for use in health screening in the primary healthcare setting. This study has implications on using tear collection as a method of ocular and systemic health screening in the primary healthcare setting.

  18. Relevance of Lipid-Based Products in the Management of Dry Eye Disease

    PubMed Central

    Amrane, Mourad; Faure, Marie-Odile; Holopainen, Juha M.; Tong, Louis

    2017-01-01

    Abstract Components of the ocular surface synergistically contribute to maintaining and protecting a smooth refractive layer to facilitate the optimal transmission of light. At the air–water interface, the tear film lipid layer (TFLL), a mixture of lipids and proteins, plays a key role in tear surface tension and is important for the physiological hydration of the ocular surface and for ocular homeostasis. Alterations in tear fluid rheology, differences in lipid composition, or downregulation of specific tear proteins are found in most types of ocular surface disease, including dry eye disease (DED). Artificial tears have long been a first line of treatment in DED and aim to replace or supplement tears. More recently, lipid-containing eye drops have been developed to more closely mimic the combination of aqueous and lipid layers of the TFLL. Over the last 2 decades, our understanding of the nature and importance of lipids in the tear film in health and disease has increased substantially. The aim of this article is to provide a brief overview of our current understanding of tear film properties and review the effectiveness of lipid-based products in the treatment of DED. Liposome lid sprays, emulsion eye drops, and other lipid-containing formulations are discussed. PMID:28956698

  19. Numerical analysis of two-fluid tearing mode instability in a finite aspect ratio cylinder

    NASA Astrophysics Data System (ADS)

    Ito, Atsushi; Ramos, Jesús J.

    2018-01-01

    The two-fluid resistive tearing mode instability in a periodic plasma cylinder of finite aspect ratio is investigated numerically for parameters such that the cylindrical aspect ratio and two-fluid effects are of order unity, hence the real and imaginary parts of the mode eigenfunctions and growth rate are comparable. Considering a force-free equilibrium, numerical solutions of the complete eigenmode equations for general aspect ratios and ion skin depths are compared and found to be in very good agreement with the corresponding analytic solutions derived by means of the boundary layer theory [A. Ito and J. J. Ramos, Phys. Plasmas 24, 072102 (2017)]. Scaling laws for the growth rate and the real frequency of the mode are derived from the analytic dispersion relation by using Taylor expansions and Padé approximations. The cylindrical finite aspect ratio effect is inferred from the scaling law for the real frequency of the mode.

  20. A unifying hypothesis for a patient with superficial siderosis, low-pressure headache, intraspinal cyst, back pain, and prominent vascularity.

    PubMed

    Kumar, Neeraj; Miller, Gary M; Piepgras, David G; Mokri, Bahram

    2010-07-01

    A source of bleeding is often not evident during the evaluation of patients with superficial siderosis of the CNS despite extensive imaging. An intraspinal fluid-filled collection of variable dimensions is frequently observed on spine MR imaging in patients with idiopathic superficial siderosis. A similar finding has also been reported in patients with idiopathic intracranial hypotension. The authors report on a patient with superficial siderosis and a longitudinally extensive intraspinal fluid-filled collection secondary to a dural tear. The patient had a history of low-pressure headaches. His spine MR imaging and spine CT suggested the possibility of an underlying vascular malformation, but none was found on angiography. Repair of the dural tear resulted in resolution of the intraspinal fluid collection and CSF abnormalities. The significance of the association between superficial siderosis and idiopathic intracranial hypotension, and potential therapeutic and pathophysiological implications, are the subject of this report.

  1. Relationship Between Deltoid and Rotator Cuff Muscles During Dynamic Shoulder Abduction: A Biomechanical Study of Rotator Cuff Tear Progression.

    PubMed

    Dyrna, Felix; Kumar, Neil S; Obopilwe, Elifho; Scheiderer, Bastian; Comer, Brendan; Nowak, Michael; Romeo, Anthony A; Mazzocca, Augustus D; Beitzel, Knut

    2018-05-01

    Previous biomechanical studies regarding deltoid function during glenohumeral abduction have primarily used static testing protocols. (1) Deltoid forces required for scapular plane abduction increase as simulated rotator cuff tears become larger, and (2) maximal abduction decreases despite increased deltoid forces. Controlled laboratory study. Twelve fresh-frozen cadaveric shoulders with a mean age of 67 years (range, 64-74 years) were used. The supraspinatus and anterior, middle, and posterior deltoid tendons were attached to individual shoulder simulator actuators. Deltoid forces and maximum abduction were recorded for the following tear patterns: intact, isolated subscapularis (SSC), isolated supraspinatus (SSP), anterosuperior (SSP + SSC), posterosuperior (infraspinatus [ISP] + SSP), and massive (SSC + SSP + ISP). Optical triads tracked 3-dimensional motion during dynamic testing. Fluoroscopy and computed tomography were used to measure critical shoulder angle, acromial index, and superior humeral head migration with massive tears. Mean values for maximum glenohumeral abduction and deltoid forces were determined. Linear mixed-effects regression examined changes in motion and forces over time. Pearson product-moment correlation coefficients ( r) among deltoid forces, critical shoulder angles, and acromial indices were calculated. Shoulders with an intact cuff required 193.8 N (95% CI, 125.5 to 262.1) total deltoid force to achieve 79.8° (95% CI, 66.4° to 93.2°) of maximum glenohumeral abduction. Compared with native shoulders, abduction decreased after simulated SSP (-27.2%; 95% CI, -43.3% to -11.1%, P = .04), anterosuperior (-51.5%; 95% CI, -70.2% to -32.8%, P < .01), and massive (-48.4%; 95% CI, -65.2% to -31.5%, P < .01) cuff tears. Increased total deltoid forces were required for simulated anterosuperior (+108.1%; 95% CI, 68.7% to 147.5%, P < .01) and massive (+57.2%; 95% CI, 19.6% to 94.7%, P = .05) cuff tears. Anterior deltoid forces were significantly greater in anterosuperior ( P < .01) and massive ( P = .03) tears. Middle deltoid forces were greater with anterosuperior tears ( P = .03). Posterior deltoid forces were greater with anterosuperior ( P = .02) and posterosuperior ( P = .04) tears. Anterior deltoid force was negatively correlated ( r = -0.89, P = .01) with critical shoulder angle (34.3°; 95% CI, 32.0° to 36.6°). Deltoid forces had no statistical correlation with acromial index (0.55; 95% CI, 0.48 to 0.61). Superior migration was 8.3 mm (95% CI, 5.5 to 11.1 mm) during testing of massive rotator cuff tears. Shoulders with rotator cuff tears require considerable compensatory deltoid function to prevent abduction motion loss. Anterosuperior tears resulted in the largest motion loss despite the greatest increase in deltoid force. Rotator cuff tears place more strain on the deltoid to prevent abduction motion loss. Fatigue or injury to the deltoid may result in a precipitous decline in abduction, regardless of tear size.

  2. Analytical and numerical treatment of drift-tearing modes in plasma slab

    NASA Astrophysics Data System (ADS)

    Mirnov, V. V.; Hegna, C. C.; Sovinec, C. R.; Howell, E. C.

    2016-10-01

    Two-fluid corrections to linear tearing modes includes 1) diamagnetic drifts that reduce the growth rate and 2) electron and ion decoupling on short scales that can lead to fast reconnection. We have recently developed an analytical model that includes effects 1) and 2) and important contribution from finite electron parallel thermal conduction. Both the tendencies 1) and 2) are confirmed by an approximate analytic dispersion relation that is derived using a perturbative approach of small ion-sound gyroradius ρs. This approach is only valid at the beginning of the transition from the collisional to semi-collisional regimes. Further analytical and numerical work is performed to cover the full interval of ρs connecting these two limiting cases. Growth rates are computed from analytic theory with a shooting method. They match the resistive MHD regime with the dispersion relations known at asymptotically large ion-sound gyroradius. A comparison between this analytical treatment and linear numerical simulations using the NIMROD code with cold ions and hot electrons in plasma slab is reported. The material is based on work supported by the U.S. DOE and NSF.

  3. High Temperature, Long Service Life Fuel Cell Bladder Materials

    DTIC Science & Technology

    2004-03-01

    50 Table 19. Inner Liner Rubber , D471 Results – Fluid Aging in JP8+100 @ 225°F............................. 52 Table 20. Inner Liner Rubber ...Tensile Properties – Fluid Aging in JP8+100 @ 225°F ..................... 52 Table 21. Inner Liner Rubber , Tear Properties – Fluid Aging in JP8+100...samples in accordance with ASTM D 471: Test Method for Rubber Property - Effects of Liquids. Fluid aging experiments were performed in friction

  4. Dynamics and function of the tear film in relation to the blink cycle.

    PubMed

    Braun, R J; King-Smith, P E; Begley, C G; Li, Longfei; Gewecke, N R

    2015-03-01

    Great strides have recently been made in quantitative measurements of tear film thickness and thinning, mathematical modeling thereof and linking these to sensory perception. This paper summarizes recent progress in these areas and reports on new results. The complete blink cycle is used as a framework that attempts to unify the results that are currently available. Understanding of tear film dynamics is aided by combining information from different imaging methods, including fluorescence, retroillumination and a new high-speed stroboscopic imaging system developed for studying the tear film during the blink cycle. During the downstroke of the blink, lipid is compressed as a thick layer just under the upper lid which is often released as a narrow thick band of lipid at the beginning of the upstroke. "Rippling" of the tear film/air interface due to motion of the tear film over the corneal surface, somewhat like the flow of water in a shallow stream over a rocky streambed, was observed during lid motion and treated theoretically here. New mathematical predictions of tear film osmolarity over the exposed ocular surface and in tear breakup are presented; the latter is closely linked to new in vivo observations. Models include the effects of evaporation, osmotic flow through the cornea and conjunctiva, quenching of fluorescence, tangential flow of aqueous tears and diffusion of tear solutes and fluorescein. These and other combinations of experiment and theory increase our understanding of the fluid dynamics of the tear film and its potential impact on the ocular surface. Copyright © 2014 Elsevier Ltd. All rights reserved.

  5. Dynamics and function of the tear film in relation to the blink cycle

    PubMed Central

    Braun, R.J.; King-Smith, P.E.; Begley, C.G.; Li, Longfei; Gewecke, N.R.

    2014-01-01

    Great strides have recently been made in quantitative measurements of tear film thickness and thinning, mathematical modeling thereof and linking these to sensory perception. This paper summarizes recent progress in these areas and reports on new results. The complete blink cycle is used as a framework that attempts to unify the results that are currently available. Understanding of tear film dynamics is aided by combining information from different imaging methods, including fluorescence, retroillumination and a new high-speed stroboscopic imaging system developed for studying the tear film during the blink cycle. During the downstroke of the blink, lipid is compressed as a thick layer just under the upper lid which is often released as a narrow thick band of lipid at the beginning of the upstroke. “Rippling” of the tear film/air interface due to motion of the tear film over the corneal surface, somewhat like the flow of water in a shallow stream over a rocky streambed, was observed during lid motion and treated theoretically here. New mathematical predictions of tear film osmolarity over the exposed ocular surface and in tear breakup are presented; the latter is closely linked to new in vivo observations. Models include the effects of evaporation, osmotic flow through the cornea and conjunctiva, quenching of fluorescence, tangential flow of aqueous tears and diffusion of tear solutes and fluorescein. These and other combinations of experiment and theory increase our understanding of the fluid dynamics of the tear film and its potential impact on the ocular surface. PMID:25479602

  6. Antimicrobial Compounds in Tears

    PubMed Central

    McDermott, Alison M.

    2013-01-01

    The tear film coats the cornea and conjunctiva and serves several important functions. It provides lubrication, prevents drying of the ocular surface epithelia, helps provide a smooth surface for refracting light, supplies oxygen and is an important component of the innate defense system of the eye providing protection against a range of potential pathogens. This review describes both classic antimicrobial compounds found in tears such as lysozyme and some more recently identified such as members of the cationic antimicrobial peptide family and surfactant protein-D as well as potential new candidate molecules that may contribute to antimicrobial protection. As is readily evident from the literature review herein, tears, like all mucosal fluids, contain a plethora of molecules with known antimicrobial effects. That all of these are active in vivo is debatable as many are present in low concentrations, may be influenced by other tear components such as the ionic environment, and antimicrobial action may be only one of several activities ascribed to the molecule. However, there are many studies showing synergistic/additive interactions between several of the tear antimicrobials and it is highly likely that cooperativity between molecules is the primary way tears are able to afford significant antimicrobial protection to the ocular surface in vivo. In addition to effects on pathogen growth and survival some tear components prevent epithelial cell invasion and promote the epithelial expression of innate defense molecules. Given the protective role of tears a number of scenarios can be envisaged that may affect the amount and/or activity of tear antimicrobials and hence compromise tear immunity. Two such situations, dry eye disease and contact lens wear, are discussed here. PMID:23880529

  7. MaquiBright™ standardized maqui berry extract significantly increases tear fluid production and ameliorates dry eye-related symptoms in a clinical pilot trial.

    PubMed

    Hitoe, S; Tanaka, J; Shimoda, H

    2014-09-01

    Dry eye symptoms, resulting from insufficient tear fluid generation, represent a considerable burden for a largely underestimated number of people. We concluded from earlier pre-clinical investigations that the etiology of dry eyes encompasses oxidative stress burden to lachrymal glands and that antioxidant MaquiBright™ Aristotelia chilensis berry extract helps restore glandular activity. In this pilot trial we investigated 13 healthy volunteers with moderately dry eyes using Schirmer test, as well as a questionnaire which allows for estimating the impact of dry eyes on daily routines. Study participants were assigned to one of two groups, receiving MaquiBright™ at daily dosage of either 30 mg (N.=7) or 60 mg (N.=6) over a period of 60 days. Both groups presented with significantly (P<0.05) improved tear fluid volume already after 30 days treatment. Schirmer test showed an increase from baseline 16.3±2.6 mm to 24.4±4.8 mm (P<0.05) with 30 mg MaquiBright™ and from 18.7±1.9 mm to 27.6±3.4 mm with 60 mg (P<0.05), respectively. Following treatment with 30 mg MaquiBright™ for further 30 days, tear fluid volume dropped slightly to 20.5±2.8 mm, whereas the improvement persisted with 60 mg treatment at 27.1±2.7 mm after 60 days treatment (P<0.05 vs. baseline). The burden of eye dryness on daily routines was evaluated employing the "Dry Eye-related Quality of life Score" (DEQS), with values spanning from zero (impact) to a maximum score of 60. Participants had comparable baseline values of 41.0±7.7 (30 mg) and 40.2±6.3 (60 mg). With 30 mg treatment the score significantly decreased to 21.8±3.9 and 18.9±3.9, after 30 and 60 days, respectively. With 60 mg treatment the DEQS significantly decreased to 26.9±5.3 and 11.1±2.7, after 30 and 60 days, respectively. Blood was drawn for safety analyses (complete blood rheology and -chemistry) at all three investigative time points without negative findings. In conclusion, while daily supplementation with 30 mg MaquiBright™ is effective, the dosage of 60 significantly increased tear fluid volume at all investigative time points and decreased dry eye symptoms to almost a quarter from initial values after two months treatment.

  8. Quantification of surfactant proteins in tears of patients suffering from dry eye disease compared to healthy subjects.

    PubMed

    Posa, Andreas; Paulsen, Friedrich; Dietz, Richard; Garreis, Fabian; Sander, Ralph; Schicht, Martin; Sel, Saadettin; Scholz, Michael; Hammer, Christian M; Bräuer, Lars

    2018-03-01

    To quantify and compare the amounts of surfactant proteins SP-A, SP-B, SP-C and SP-D in the tear fluid collected from patients with dry eye syndrome and from individuals with a healthy ocular surface. Schirmer strips were used to collect tear fluid from both eyes of 241 volunteers (99 men, 142 women; age range: 18-87 years). Dry eye syndrome was diagnosed by ophthalmologists in 125 patients, whereas the healthy control group comprised 116 individuals. The total protein concentration was determined via Bradford assay. The relative concentration of surfactant proteins SP-A through -D was measured by enzyme-linked immuno-sorbent assay (ELISA). The mean relative concentrations of SP-A, SP-C and SP-D were significantly higher in the dry eye group as compared to the healthy controls (p<0.05, one-way ANOVA). SP-B was also detected at a higher concentration in the dry eye group, but the difference to the control group was not statistically significant. The upregulation of SP-A and SP-D in the dry eye group is probably related to these proteins' known antimicrobial and immunomodulatory effects at the ocular surface. It may represent a pathophysiological response to the inflammatory condition of the ocular surface in dry eye. The upregulation of SP-B and SP-C may represent an effort of the lacrimal system to reduce surface tension and thus to counteract the increased tendency of the tear film to tear in dry eye. Copyright © 2017 Elsevier GmbH. All rights reserved.

  9. Hot tearing studies in AA5182

    NASA Astrophysics Data System (ADS)

    van Haaften, W. M.; Kool, W. H.; Katgerman, L.

    2002-10-01

    One of the major problems during direct chill (DC) casting is hot tearing. These tears initiate during solidification of the alloy and may run through the entire ingot. To study the hot tearing mechanism, tensile tests were carried out in semisolid state and at low strain rates, and crack propagation was studied in situ by scanning electron microscopy (SEM). These experimentally induced cracks were compared with hot tears developed in an AA5182 ingot during a casting trial in an industrial research facility. Similarities in the microstructure of the tensile test specimens and the hot tears indicate that hot tearing can be simulated by performing tensile tests at semisolid temperatures. The experimental data were compared with existing hot tearing models and it was concluded that the latter are restricted to relatively high liquid fractions because they do not take into account the existence of solid bridges in the crack.

  10. Influence of Ophthalmic Solutions on Tear Components.

    PubMed

    Shigeyasu, Chika; Yamada, Masakazu; Akune, Yoko

    2016-11-01

    Tear fluids are a mixture of secretions derived from lacrimal glands, accessory lacrimal glands, conjunctiva, and meibomian glands. Compositional changes to tears occur in the normal state and during ocular surface disease, such as dry eye conditions. We have investigated compositional changes to tears after topical application of ophthalmic solutions, with regard to tear-specific proteins (secretory immunoglobulin A, lactoferrin, lipocalin-1, and lysozyme) and ocular surface mucin in normal and dry eye conditions using high-performance liquid chromatography. After application of saline solution (0.9% sodium chloride) in normal subjects, transient but significant decreases in all tear components were observed. The recovery of protein concentrations took up to 30 minutes and lasted longer when the saline solution was applied more frequently. When applying ophthalmic solutions, a balance between washout and dilutional effects should be considered in addition to the therapeutic effect. Investigation of the effect of diquafosol solution (3%) in normal subjects revealed a significant increase in sialic acid concentration, a marker of ocular mucin, at 5 minutes after application, whereas a significant decrease was observed with saline. This result indicates the accelerated secretion of mucin from ocular tissues induced by diquafosol. A clinical study to determine the efficacy of diquafosol in patients with dry eye revealed improvements in tear breakup time, keratoconjunctival staining scores, and Schirmer test score, accompanied by an increase in sialic acid concentration in tears. Investigating normal and dry eye conditions through tear analysis may clarify the pathophysiology of dry eye conditions and support the efficacy of treatments.

  11. Effects of a warm compress containing menthol on the tear film in healthy subjects and dry eye patients

    NASA Astrophysics Data System (ADS)

    Arita, Reiko; Morishige, Naoyuki; Sakamoto, Ichiro; Imai, Natsuko; Shimada, Yuko; Igaki, Michihito; Suzuki, Atsushi; Itoh, Kouzo; Tsubota, Kazuo

    2017-04-01

    Menthol is thought to stimulate lacrimation via activation of cold-sensitive primary afferent neurons in the cornea. We evaluated a warm compress containing menthol as a potential treatment for dry eye by examining its effects on the tear film in healthy subjects (n = 20) and dry eye patients (n = 35). Disposable eyelid-warming steamers that either did (MH) or did not (HO) contain menthol were applied to one eye of each subject either once only for 10 min or repeatedly over 2 weeks. Single application of MH significantly increased tear meniscus volume (P = 8.6 × 10-5, P = 1.3 × 10-5) and tear film breakup time (P = 0.006, P = 0.002) as well as improved meibum condition in healthy subjects and dry eye patients, respectively. Repeated application of MH significantly increased tear meniscus volume (P = 0.004, P = 1.7 × 10-4) and tear film breakup time (P = 0.037, P = 0.010) in healthy subjects and dry eye patients, respectively. Repeated application of MH thus induced persistent increases in tear fluid volume and tear film stability in dry eye patients, suggesting that repeated use of a warm compress containing menthol is a potential novel treatment for dry eye disease.

  12. A Multicenter Study of the Presentation, Treatment, and Outcomes of Cervical Dural Tears.

    PubMed

    O'Neill, Kevin R; Fehlings, Michael G; Mroz, Thomas E; Smith, Zachary A; Hsu, Wellington K; Kanter, Adam S; Steinmetz, Michael P; Arnold, Paul M; Mummaneni, Praveen V; Chou, Dean; Nassr, Ahmad; Qureshi, Sheeraz A; Cho, Samuel K; Baird, Evan O; Smith, Justin S; Shaffrey, Christopher; Tannoury, Chadi A; Tannoury, Tony; Gokaslan, Ziya L; Gum, Jeffrey L; Hart, Robert A; Isaacs, Robert E; Sasso, Rick C; Bumpass, David B; Bydon, Mohamad; Corriveau, Mark; De Giacomo, Anthony F; Derakhshan, Adeeb; Jobse, Bruce C; Lubelski, Daniel; Lee, Sungho; Massicotte, Eric M; Pace, Jonathan R; Smith, Gabriel A; Than, Khoi D; Riew, K Daniel

    2017-04-01

    Retrospective multicenter case series study. Because cervical dural tears are rare, most surgeons have limited experience with this complication. A multicenter study was performed to better understand the presentation, treatment, and outcomes following cervical dural tears. Multiple surgeons from 23 institutions retrospectively identified 21 rare complications that occurred between 2005 and 2011, including unintentional cervical dural tears. Demographic data and surgical history were obtained. Clinical outcomes following surgery were assessed, and any reoperations were recorded. Neck Disability Index (NDI), modified Japanese Orthopaedic Association (mJOA), Nurick classification (NuC), and Short-Form 36 (SF36) scores were recorded at baseline and final follow-up at certain centers. All data were collected, collated, and analyzed by a private research organization. There were 109 cases of cervical dural tears among 18 463 surgeries performed. In 101 cases (93%) there was no clinical sequelae following successful dural tear repair. There were statistical improvements ( P < .05) in mJOA and NuC scores, but not NDI or SF36 scores. No specific baseline or operative factors were found to be associated with the occurrence of dural tears. In most cases, no further postoperative treatments of the dural tear were required, while there were 13 patients (12%) that required subsequent treatment of cerebrospinal fluid drainage. Analysis of those requiring further treatments did not identify an optimum treatment strategy for cervical dural tears. In this multicenter study, we report our findings on the largest reported series (n = 109) of cervical dural tears. In a vast majority of cases, no subsequent interventions were required and no clinical sequelae were observed.

  13. Quantitation of 47 human tear proteins using high resolution multiple reaction monitoring (HR-MRM) based-mass spectrometry.

    PubMed

    Tong, Louis; Zhou, Xi Yuan; Jylha, Antti; Aapola, Ulla; Liu, Dan Ning; Koh, Siew Kwan; Tian, Dechao; Quah, Joanne; Uusitalo, Hannu; Beuerman, Roger W; Zhou, Lei

    2015-02-06

    Tear proteins are intimately related to the pathophysiology of the ocular surface. Many recent studies have demonstrated that the tear is an accessible fluid for studying eye diseases and biomarker discovery. This study describes a high resolution multiple reaction monitoring (HR-MRM) approach for developing assays for quantification of biologically important tear proteins. Human tear samples were collected from 1000 subjects with no eye complaints (411 male, 589 female, average age: 55.5±14.5years) after obtaining informed consent. Tear samples were collected using Schirmer's strips and pooled into a single global control sample. Quantification of proteins was carried out by selecting "signature" peptides derived by trypsin digestion. A 1-h nanoLC-MS/MS run was used to quantify the tear proteins in HR-MRM mode. Good reproducibility of signal intensity (using peak areas) was demonstrated for all 47 HR-MRM assays with an average coefficient of variation (CV%) of 4.82% (range: 1.52-10.30%). All assays showed consistent retention time with a CV of less than 0.80% (average: 0.57%). HR-MRM absolute quantitation of eight tear proteins was demonstrated using stable isotope-labeled peptides. In this study, we demonstrated for the first time the technique to quantify 47 human tear proteins in HR-MRM mode using approximately 1μl of human tear sample. These multiplexed HR-MRM-based assays show great promise of further development for biomarker validation in human tear samples. Both discovery-based and targeted quantitative proteomics can be achieved in a single quadrupole time-of-flight mass spectrometer platform (TripleTOF 5600 system). Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Antimicrobial compounds in tears.

    PubMed

    McDermott, Alison M

    2013-12-01

    The tear film coats the cornea and conjunctiva and serves several important functions. It provides lubrication, prevents drying of the ocular surface epithelia, helps provide a smooth surface for refracting light, supplies oxygen and is an important component of the innate defense system of the eye providing protection against a range of potential pathogens. This review describes both classic antimicrobial compounds found in tears such as lysozyme and some more recently identified such as members of the cationic antimicrobial peptide family and surfactant protein-D as well as potential new candidate molecules that may contribute to antimicrobial protection. As is readily evident from the literature review herein, tears, like all mucosal fluids, contain a plethora of molecules with known antimicrobial effects. That all of these are active in vivo is debatable as many are present in low concentrations, may be influenced by other tear components such as the ionic environment, and antimicrobial action may be only one of several activities ascribed to the molecule. However, there are many studies showing synergistic/additive interactions between several of the tear antimicrobials and it is highly likely that cooperativity between molecules is the primary way tears are able to afford significant antimicrobial protection to the ocular surface in vivo. In addition to effects on pathogen growth and survival some tear components prevent epithelial cell invasion and promote the epithelial expression of innate defense molecules. Given the protective role of tears a number of scenarios can be envisaged that may affect the amount and/or activity of tear antimicrobials and hence compromise tear immunity. Two such situations, dry eye disease and contact lens wear, are discussed here. Copyright © 2013 Elsevier Ltd. All rights reserved.

  15. Verification of long wavelength electromagnetic modes with a gyrokinetic-fluid hybrid model in the XGC code

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hager, Robert; Lang, Jianying; Chang, C. S.

    As an alternative option to kinetic electrons, the gyrokinetic total-f particle-in-cell (PIC) code XGC1 has been extended to the MHD/fluid type electromagnetic regime by combining gyrokinetic PIC ions with massless drift-fluid electrons. Here, two representative long wavelength modes, shear Alfven waves and resistive tearing modes, are verified in cylindrical and toroidal magnetic field geometries.

  16. Verification of long wavelength electromagnetic modes with a gyrokinetic-fluid hybrid model in the XGC code

    DOE PAGES

    Hager, Robert; Lang, Jianying; Chang, C. S.; ...

    2017-05-24

    As an alternative option to kinetic electrons, the gyrokinetic total-f particle-in-cell (PIC) code XGC1 has been extended to the MHD/fluid type electromagnetic regime by combining gyrokinetic PIC ions with massless drift-fluid electrons. Here, two representative long wavelength modes, shear Alfven waves and resistive tearing modes, are verified in cylindrical and toroidal magnetic field geometries.

  17. Suprascapular nerve anatomy during shoulder motion: a cadaveric proof of concept study with implications for neurogenic shoulder pain.

    PubMed

    Massimini, Daniel F; Singh, Anshu; Wells, Jessica H; Li, Guoan; Warner, Jon J P

    2013-04-01

    The suprascapular nerve (SSN) carries sensory fibers which may contribute to shoulder pain. Prior anatomic study demonstrated that alteration in SSN course with simulated rotator cuff tendon (RCT) tears cause tethering and potential traction injury to the nerve at the suprascapular notch. Because the SSN has been implicated as a major source of pain with RCT tearing, it is critical to understand nerve anatomy during shoulder motion. We hypothesized that we could evaluate the SSN course with a novel technique to evaluate effects of simulated RCT tears, repair, and/or release of the nerve. The course of the SSN was tracked with a dual fluoroscopic imaging system in a cadaveric model with simulated rotator cuff muscle forces during dynamic shoulder motion. After a simulated full-thickness supraspinatus/infraspinatus tendon tear, the SSN translated medially 3.5 mm at the spinoglenoid notch compared to the anatomic SSN course. Anatomic footprint repair of these tendons restored the SSN course to normal. Open release of the transverse scapular ligament caused the SSN to move 2.5 mm superior-posterior out of the suprascapular notch. This pilot study demonstrated that the dynamic SSN course can be evaluated and may be altered by a RCT tear. Preliminary results suggest release of the transverse scapular ligament allowed the SSN to move upward out of the notch. This provides a biomechanical proof of concept that SSN traction neuropathy may occur with RCT tears and that release of the transverse scapular ligament may alleviate this by altering the course of the nerve. Copyright © 2013 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  18. A novel capsulorhexis technique using shearing forces with cystotome.

    PubMed

    Karim, Shah M R; Ong, Chin T; Sleep, Tamsin J

    2010-05-15

    To demonstrate a capsulorhexis technique using predominantly shearing forces with a cystotome on a virtual reality simulator and on a human eye. Our technique involves creating the initial anterior capsular tear with a cystotome to raise a flap. The flap left unfolded on the lens surface. The cystotome tip is tilted horizontally and is engaged on the flap near the leading edge of the tear. The cystotome is moved in a circular fashion to direct the vector forces. The loose flap is constantly swept towards the centre so that it does not obscure the view on the tearing edge. Our technique has the advantage of reducing corneal wound distortion and subsequent anterior chamber collapse. The capsulorhexis flap is moved away from the tear leading edge allowing better visualisation of the direction of tear. This technique offers superior control of the capsulorhexis by allowing the surgeon to change the direction of the tear to achieve the desired capsulorhexis size. The EYESI Surgical Simulator is a realistic training platform for surgeons to practice complex capsulorhexis techniques. The shearing forces technique is a suitable alternative and in some cases a far better technique in achieving the desired capsulorhexis.

  19. Study of hot cracking potential in a 6-ton steel ingot casting

    NASA Astrophysics Data System (ADS)

    Yang, Jing'an; Liu, Baicheng; Shen, Houfa

    2018-04-01

    A new hot cracking potential (HCP) criterion, for the appearance of hot tearing in steel ingot castings, is proposed. The maximum value of the first principal stress, divided by the dynamic yield strength in the brittle temperature range (BTR), was used to identify the HCP. Experiments were carried out on a 6-ton P91 steel ingot in which severe hot tearing was detected in the upper centerline. Another ingot, with a better heat preservation riser, and without hot tearing, was used for comparison. Samples were obtained from the area of the ingot body with hot tearing, and their morphologies were inspected by a X-ray high energy industrial computed tomography. The carbon and sulfur distributions around the hot tearing were characterized by an infrared spectrometry carbon and sulfur analyzer. High temperature mechanical properties were obtained by a Gleeble thermal simulation machine, under different strain rates. Then, thermo-mechanical simulations using an elasto-viscoplastic finite-element model were conducted to analyze the stress and strain evolution during ingot solidification. The results showed that the hot tearing area, which was rich in both carbon and sulfur, was under excessive tensile stress in the BTR, bearing the highest HCP.

  20. Diagnostic imaging of the nasolacrimal drainage system. Part I. Radiological anatomy of lacrimal pathways. Physiology of tear secretion and tear outflow.

    PubMed

    Maliborski, Artur; Różycki, Radosław

    2014-04-17

    Excessive watering of the eye is a common condition in ophthalmological practice. It may be the result of excessive production of tear fluid or obstruction and insufficiency of efferent tear pathways. The differentiation between obstruction and insufficiency of the lacrimal pathways is still clinically questionable. In the diagnostic process it is necessary to perform clinical tests and additional diagnostic imaging is often needed. Dacryocystography, with or without the extension of the dynamic phase or subtraction option, still remains the criterion standard for diagnostic imaging of the lacrimal obstruction. It may help to clarify the cause and exact place of the obstruction and provide information for further management, especially surgical treatment. Increasingly, new techniques are used in diagnostic imaging of the lacrimal tract, such as computed tomography, magnetic resonance, and isotopic methods. Adequate knowledge of the anatomy and physiology of the lacrimal system and the secretion and outflow of tears is the basis for proper diagnostic imaging. The purpose of this paper is to present the exact anatomy of the lacrimal system, with particular emphasis on the radiological anatomy and the current state of knowledge about the physiology of tear secretion and drainage.

  1. Paper-based microfluidic system for tear electrolyte analysis† †We declare no competing financial interests. ‡ ‡Electronic supplementary information (ESI) available: Microscopic images of G1 paper and G41 paper under brightfield; optimization of CO2 laser radiation fluence and beam speed for ablating filter paper-G1; photographs of DI water diffusion in microfluidic channels with different lengths, different widths, different viscosities of fluid and different numbers of channels; fluorescence intensity readouts of Na+ and K+ ions with varied concentrations of fluorescent probes; effect of variations in temperature on fluorescence intensity; photographs of DMSO on G1 paper dried in the air; calibration curves of electrolyte sensing on G1 paper using microplate reader measurement; calculation of sensitivity of the fluorescent sensors based on International Union of Pure and Applied Chemistry (IUPAC) guidelines; quantification of ion interference in buffer solution and artificial tear fluid; light attenuation of LED lights using different optical filters; the design of the sample collection device and its potential clinical use; calibration curves of electrolyte sensors using the paper-based microfluidic system; quantifications of evaporation effect on sampling process; design of the sample collection device and its potential clinical use; batch-to-batch variation experiments; equation for background subtraction; movies of sample collection and measurements. See DOI: 10.1039/c6lc01450j Click here for additional data file. Click here for additional data file. Click here for additional data file. Click here for additional data file.

    PubMed Central

    Jiang, Nan; Tamayol, Ali; Ruiz-Esparza, Guillermo U.; Zhang, Yu Shrike; Medina-Pando, Sofía; Gupta, Aditi; Wolffsohn, James S.; Butt, Haider; Khademhosseini, Ali

    2017-01-01

    The analysis of tear constituents at point-of-care settings has a potential for early diagnosis of ocular disorders such as dry eye disease, low-cost screening, and surveillance of at-risk subjects. However, current minimally-invasive rapid tear analysis systems for point-of-care settings have been limited to assessment of osmolarity or inflammatory markers and cannot differentiate between dry eye subclassifications. Here, we demonstrate a portable microfluidic system that allows quantitative analysis of electrolytes in the tear fluid that is suited for point-of-care settings. The microfluidic system consists of a capillary tube for sample collection, a reservoir for sample dilution, and a paper-based microfluidic device for electrolyte analysis. The sensing regions are functionalized with fluorescent crown ethers, o-acetanisidide, and seminaphtorhodafluor that are sensitive to mono- and divalent electrolytes, and their fluorescence outputs are measured with a smartphone readout device. The measured sensitivity values of Na+, K+, Ca2+ ions and pH in artificial tear fluid were matched with the known ion concentrations within the physiological range. The microfluidic system was tested with samples having different ionic concentrations, demonstrating the feasibility for the detection of early-stage dry eye, differential diagnosis of dry eye sub-types, and their severity staging. PMID:28207920

  2. Slab tears and intermediate-depth seismicity

    USGS Publications Warehouse

    Meighan, Hallie E.; ten Brink, Uri S.; Pulliam, Jay

    2013-01-01

    Active tectonic regions where plate boundaries transition from subduction to strike slip can take several forms, such as triple junctions, acute, and obtuse corners. Well-documented slab tears that are associated with high rates of intermediate-depth seismicity are considered here: Gibraltar arc, the southern and northern ends of the Lesser Antilles arc, and the northern end of Tonga trench. Seismicity at each of these locations occurs, at times, in the form of swarms or clusters, and various authors have proposed that each marks an active locus of tear propagation. The swarms and clusters start at the top of the slab below the asthenospheric wedge and extend 30–60 km vertically downward within the slab. We propose that these swarms and clusters are generated by fluid-related embrittlement of mantle rocks. Focal mechanisms of these swarms generally fit the shear motion that is thought to be associated with the tearing process.

  3. Rheological investigation of high-acyl gellan gum hydrogel and its mixtures with simulated body fluids.

    PubMed

    Osmałek, Tomasz Zbigniew; Froelich, Anna; Jadach, Barbara; Krakowski, Marek

    2018-05-01

    Purpose Most of the studies concerning gellan have been focused on its application as a food ingredient, however, gellan is often considered as a candidate for the development of novel pharmaceutical formulations. Taking into account that gellan is ion-sensitive, it can be assumed that its initial mechanical properties can change upon contact with body secretions. Therefore, the aim of the work was to investigate the rheological properties of pure high-acyl gellan gum hydrogel (0.4%) and its mixtures with selected simulated body fluids. Methods The rheological investigations were performed on rotational rheometer and included oscillatory temperature, amplitude, and frequency sweeping. The results enabled estimation of the linear viscoelastic regime, calculation of the cross-over points, and percentage of structure recovery. Results In the case of pure hydrogel no evidence of thermosensitivity was observed in the range of 20-40°C. In pH = 1.2 (NaCl/HCl) the hydrogel structure was almost entirely destroyed. Mixing with phosphate buffer (pH = 4.5) resulted in higher gel strength than after dilution with deionized water. The opposite effect was observed in the case of pH = 7.4. The studies performed for the mixture of GG hydrogel and mucin indicated interaction between the components. The hydrogel elasticity increased in the presence of simulated tear, but decreased in simulated saliva and vaginal fluid. Conclusions In this study, it was shown that the stability of a three-dimensional gellan structure may be affected by pH and the presence of mucin which most probably competed with gellan gum in divalent cations binding. The observations presented in this study may be important in terms of potential application of gellan gum as a potential carrier in drug delivery systems.

  4. Treatment of cerebrospinal fluid leak after spine surgery.

    PubMed

    Fang, Zhao; Tian, Rong; Jia, Yu-Tao; Xu, Tian-Tong; Liu, Yang

    2017-04-01

    Owing to the complexity of spinal surgery, there is a great prevalence of dural tear causing cerebrospinal fluid (CSF) leakage. Many studies focused on suture repair for dural tear to stop CSF leak. Now some new treatment strategies have shown a promising effect that is listed as follows: 1) creating watertight dural closure to stop CSF leak with the help of dural substitute material; and 2) retarding CSF leak by changing pressure difference, including reducing the subarachnoid fluid pressure, increasing the epidural space pressure and both. In fact several methods mentioned above are usually combined to treat CSF leak. However, no update review summarized the relevant studies implemented in recent years. In this review, the authors would compare the effects of different dural closure techniques, and introduce the latest treatment methods and mechanisms. Copyright © 2017 Daping Hospital and the Research Institute of Surgery of the Third Military Medical University. Production and hosting by Elsevier B.V. All rights reserved.

  5. The adhesion of Pseudomonas aeruginosa to high molecular weight human tear film species corresponds to glycoproteins reactive with Sambucus nigra lectin.

    PubMed

    Aristoteli, Lina Panayiota; Willcox, Mark D P

    2006-11-01

    Pseudomonas aeruginosa is a pathogen gaining prevalence in contact lens-related corneal ulcers. Tear outflow protects the ocular surface, where high molecular weight tear glycoproteins bind bacteria for removal from the eye. The purpose of the present study was to identify glycoproteins in human tears involved in the adhesion of ocular P. aeruginosa isolates. Basal human tears were applied to a bacterial adhesion assay involving electrophoretic separation of tear components, transfer to nitrocellulose and incubation with biotin-labelled bacteria. Glycoproteins were further characterised using lectin profiling. The results showed large-dimension agarose gels were imperative for the detection of at least four glycoproteins with a migration >200 kDa, including species not previously identified. P. aeruginosa 6294 preferentially bound to a well-defined glycoprotein near the origin of the gel that, unlike other glycoproteins >200 kDa, reacted with Sambucus nigra lectin (sialic acid alpha2-6) but not WGA lectin (N-acetylglucosamine, sialic acid alpha2-3). Adhesion did not involve free biotin label or hydrophobic interactions. Also, the pre-incubation of separated tear glycoproteins with S. nigra lectin increased subsequent adhesion of 6294 to this tear glycoprotein. The less virulent Paer1 strain showed diffuse adhesion in the S. nigra-reactive region at the gel origin. In conclusion, an overlay adhesion assay was developed that identified slow-migrating sialylated glycoprotein species in human tears preferentially bound by P. aeruginosa ocular strains, and S. nigra lectin seemed to enhance the interaction. The study provides a basis for direct investigation of bacterial adhesion to glycoproteins with an apparent migration >200 kDa in tear fluid.

  6. Efficacy of Rebamipide Instillation for Contact Lens Discomfort With Dry Eye.

    PubMed

    Igarashi, Tsutomu; Kobayashi, Maika; Yaguchi, Chiemi; Fujimoto, Chiaki; Suzuki, Hisaharu; Takahashi, Hiroshi

    2017-11-10

    To examine the effects of rebamipide ophthalmic solution on the symptoms, signs, and cytokine concentrations in tear fluid among soft contact lens (SCL) wearers with Dry eye disease (DED). From November 2015 to June 2017, this open-label, single-arm study examined 40 eyes of 20 SCL wearers with DED who had been using daily disposable SCLs for >3 months (mean age, 30.0±8.33 years; range, 20-47 years). Signs, symptoms, and cytokine concentrations were assessed before and 4 weeks after starting 2% rebamipide ophthalmic solution 4 times/day. Dry eye disease was diagnosed according to: compromised tear dynamics (Schirmer test ≤5 mm or tear break-up time (TBUT) ≤5 sec); ocular surface abnormalities (positive vital staining with fluorescein or lissamine green); and presence of symptoms. Touch thresholds using a Cochet-Bonnet anesthesiometer were also determined for the cornea and conjunctivae. Symptoms were assessed using the 12-item Ocular Surface Disease Index questionnaire. Concentrations of cytokines in tear fluid were measured. Significant improvements in signs were seen for TBUT, surface abnormalities, and touch thresholds. Ocular Surface Disease Index scores likewise improved significantly in all the 12 items. Of the cytokines measured, only interleukin-1β, interleukin-8, and monocyte chemotactic protein-1 were found in ≥60% of tear samples, with no significant differences in concentrations before and after rebamipide use. Rebamipide significantly improved all signs and symptoms in patients with DED who wore daily disposable SCLs. Rebamipide is effective for DED treatment with SCL wear.This is an open access article distributed under the Creative Commons Attribution License 4.0 (CCBY), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

  7. Supercritical fluid-mediated liposomes containing cyclosporin A for the treatment of dry eye syndrome in a rabbit model: comparative study with the conventional cyclosporin A emulsion

    PubMed Central

    Karn, Pankaj Ranjan; Kim, Hyun Do; Kang, Han; Sun, Bo Kyung; Jin, Su-Eon; Hwang, Sung-Joo

    2014-01-01

    Background The objective of this study was to compare the efficacy of cyclosporin (CsA)-encapsulated liposomes with the commercially available CsA emulsion (Restasis®) for the treatment of dry eye syndrome in rabbits. Methods Liposomes containing CsA were prepared by the supercritical fluid (SCF) method consisted of phosphatidylcholine from soybean (SCF-S100) and egg lecithins (SCF-EPCS). An in vitro permeation study was carried out using artificial cellulose membrane in Franz diffusion cells. Dry eye syndrome was induced in male albino rabbits and further subdivided into untreated, Restasis®-treated, EPCS, and S100-treated groups. Tear formation in the dry-eye-induced rabbits was evaluated using the Schirmer tear test. All formulations were also evaluated by ocular irritation tests using the Draize eye and winking methods with the determination of CsA concentration in rabbit tears. Results After the treatment, the Schirmer tear test value significantly improved in EPCS-treated (P=0.005) and S100-treated (P=0.018) groups compared to the Restasis®-treated group. The AUC0–24 h for rabbit’s tear film after the administration of SCF-S100 was 32.75±9.21 μg·h/mg which was significantly higher than that of 24.59±8.69 μg·h/mg reported with Restasis®. Liposomal CsA formulations used in this study showed lower irritation in rabbit eyes compared with Restasis®. Conclusion These results demonstrate that the novel SCF-mediated liposomal CsA promises a significant improvement in overcoming the challenges associated with the treatment of dry eyes. PMID:25143728

  8. Supercritical fluid-mediated liposomes containing cyclosporin A for the treatment of dry eye syndrome in a rabbit model: comparative study with the conventional cyclosporin A emulsion.

    PubMed

    Karn, Pankaj Ranjan; Kim, Hyun Do; Kang, Han; Sun, Bo Kyung; Jin, Su-Eon; Hwang, Sung-Joo

    2014-01-01

    The objective of this study was to compare the efficacy of cyclosporin (CsA)-encapsulated liposomes with the commercially available CsA emulsion (Restasis) for the treatment of dry eye syndrome in rabbits. Liposomes containing CsA were prepared by the supercritical fluid (SCF) method consisted of phosphatidylcholine from soybean (SCF-S100) and egg lecithins (SCF-EPCS). An in vitro permeation study was carried out using artificial cellulose membrane in Franz diffusion cells. Dry eye syndrome was induced in male albino rabbits and further subdivided into untreated, Restasis-treated, EPCS, and S100-treated groups. Tear formation in the dry-eye-induced rabbits was evaluated using the Schirmer tear test. All formulations were also evaluated by ocular irritation tests using the Draize eye and winking methods with the determination of CsA concentration in rabbit tears. After the treatment, the Schirmer tear test value significantly improved in EPCS-treated (P=0.005) and S100-treated (P=0.018) groups compared to the Restasis-treated group. The AUC₀₋₂₄ h for rabbit's tear film after the administration of SCF-S100 was 32.75±9.21 μg·h/mg which was significantly higher than that of 24.59±8.69 μg·h/mg reported with Restasis. Liposomal CsA formulations used in this study showed lower irritation in rabbit eyes compared with Restasis. These results demonstrate that the novel SCF-mediated liposomal CsA promises a significant improvement in overcoming the challenges associated with the treatment of dry eyes.

  9. The spring ligament recess of the talocalcaneonavicular joint: depiction on MR images with cadaveric and histologic correlation.

    PubMed

    Desai, Kapil R; Beltran, Luis S; Bencardino, Jenny T; Rosenberg, Zehava S; Petchprapa, Catherine; Steiner, German

    2011-05-01

    The objective of this study was to describe the anatomy and MR appearance of the spring ligament recess of the talocalcaneonavicular joint. Forty-nine MR examinations of the ankle with a spring ligament recess were prospectively collected. The size of the recess was measured. The presence of the following variables was recorded: talocalcaneonavicular joint effusion, ankle joint effusion, talar head impaction, acute lateral ankle sprain, chronic lateral ankle sprain, spring ligament tear, sinus tarsi ligament tear, talar dome osteochondral injury, and talonavicular osteoarthrosis. The Fisher exact test was performed to quantify the association of the talocalcaneonavicular effusion with the other variables. MR arthrography and dissection with histologic analysis were performed in two cadaveric ankles. Twenty-four men and 25 women (average age, 39 years; range, 21-77 years) were included in the study. The average size of the fluid collection was 0.4 × 0.8 cm (range, 0.2-0.9 × 0.4-1.5 cm). The prevalence of the measured variables was talocalcaneonavicular joint effusion, 67.3%; ankle joint effusion, 61.2%; talar head impaction, 32.7%; acute lateral ankle sprain, 28.6%; chronic lateral ankle sprain, 59.2%; spring ligament tear, 14.3%; sinus tarsi ligament tear, 12.2%; talar dome osteochondral lesion, 20.4%; and talonavicular osteoarthrosis, 18.4%. There was a higher prevalence of talar head impaction among individuals with talocalcaneonavicular joint effusion (p = 0.0522). Cadaveric study revealed communication between the talocalcaneonavicular joint and the spring ligament recess. The spring ligament recess is a synovium-lined, fluid-filled space that communicates with the talocalcaneonavicular joint. The recess should be distinguished from a tear of the plantar components of the spring ligament.

  10. Dual interferometer for dynamic measurement of corneal topography

    NASA Astrophysics Data System (ADS)

    Micali, Jason D.; Greivenkamp, John E.

    2016-08-01

    The cornea is the anterior most surface of the eye and plays a critical role in vision. A thin fluid layer, the tear film, coats the outer surface of the cornea and serves to protect, nourish, and lubricate the cornea. At the same time, the tear film is responsible for creating a smooth continuous surface, where the majority of refraction takes place in the eye. A significant component of vision quality is determined by the shape of the cornea and stability of the tear film. A dual interferometer system for measuring the dynamic corneal topography is designed, built, verified, and qualified by testing on human subjects. The system consists of two coaligned simultaneous phase-shifting polarization-splitting Twyman-Green interferometers. The primary interferometer measures the surface of the tear film while the secondary interferometer tracks the absolute position of the cornea, which provides enough information to reconstruct the absolute shape of the cornea. The results are high-resolution and high-accuracy surface topography measurements of the in vivo tear film and cornea that are captured at standard camera frame rates.

  11. Coupled Kelvin-Helmholtz and Tearing Mode Instabilities at the Mercury's Magnetopause

    NASA Astrophysics Data System (ADS)

    Ivanovski, S. L.; Milillo, A.; Kartalev, M.; Massetti, S.

    2018-05-01

    A MHD approach for numerical simulations of coupled Kelvin-Helmholtz and tearing mode instabilities has been applied to Mercury’s magnetopause and used to perform a physical parameters study constrained by the MESSENGER data.

  12. Quantitative body fluid proteomics in medicine - A focus on minimal invasiveness.

    PubMed

    Csősz, Éva; Kalló, Gergő; Márkus, Bernadett; Deák, Eszter; Csutak, Adrienne; Tőzsér, József

    2017-02-05

    Identification of new biomarkers specific for various pathological conditions is an important field in medical sciences. Body fluids have emerging potential in biomarker studies especially those which are continuously available and can be collected by non-invasive means. Changes in the protein composition of body fluids such as tears, saliva, sweat, etc. may provide information on both local and systemic conditions of medical relevance. In this review, our aim is to discuss the quantitative proteomics techniques used in biomarker studies, and to present advances in quantitative body fluid proteomics of non-invasively collectable body fluids with relevance to biomarker identification. The advantages and limitations of the widely used quantitative proteomics techniques are also presented. Based on the reviewed literature, we suggest an ideal pipeline for body fluid analyses aiming at biomarkers discoveries: starting from identification of biomarker candidates by shotgun quantitative proteomics or protein arrays, through verification of potential biomarkers by targeted mass spectrometry, to the antibody-based validation of biomarkers. The importance of body fluids as a rich source of biomarkers is discussed. Quantitative proteomics is a challenging part of proteomics applications. The body fluids collected by non-invasive means have high relevance in medicine; they are good sources for biomarkers used in establishing the diagnosis, follow up of disease progression and predicting high risk groups. The review presents the most widely used quantitative proteomics techniques in body fluid analysis and lists the potential biomarkers identified in tears, saliva, sweat, nasal mucus and urine for local and systemic diseases. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Human body fluid proteome analysis

    PubMed Central

    Hu, Shen; Loo, Joseph A.; Wong, David T.

    2010-01-01

    The focus of this article is to review the recent advances in proteome analysis of human body fluids, including plasma/serum, urine, cerebrospinal fluid, saliva, bronchoalveolar lavage fluid, synovial fluid, nipple aspirate fluid, tear fluid, and amniotic fluid, as well as its applications to human disease biomarker discovery. We aim to summarize the proteomics technologies currently used for global identification and quantification of body fluid proteins, and elaborate the putative biomarkers discovered for a variety of human diseases through human body fluid proteome (HBFP) analysis. Some critical concerns and perspectives in this emerging field are also discussed. With the advances made in proteomics technologies, the impact of HBFP analysis in the search for clinically relevant disease biomarkers would be realized in the future. PMID:17083142

  14. Human body fluid proteome analysis.

    PubMed

    Hu, Shen; Loo, Joseph A; Wong, David T

    2006-12-01

    The focus of this article is to review the recent advances in proteome analysis of human body fluids, including plasma/serum, urine, cerebrospinal fluid, saliva, bronchoalveolar lavage fluid, synovial fluid, nipple aspirate fluid, tear fluid, and amniotic fluid, as well as its applications to human disease biomarker discovery. We aim to summarize the proteomics technologies currently used for global identification and quantification of body fluid proteins, and elaborate the putative biomarkers discovered for a variety of human diseases through human body fluid proteome (HBFP) analysis. Some critical concerns and perspectives in this emerging field are also discussed. With the advances made in proteomics technologies, the impact of HBFP analysis in the search for clinically relevant disease biomarkers would be realized in the future.

  15. SFTA3 - a novel surfactant protein of the ocular surface and its role in corneal wound healing and tear film surface tension.

    PubMed

    Schicht, Martin; Garreis, Fabian; Hartjen, Nadine; Beileke, Stephanie; Jacobi, Christina; Sahin, Afsun; Holland, Detlef; Schröder, Henrik; Hammer, Christian M; Paulsen, Friedrich; Bräuer, Lars

    2018-06-28

    The study aimed to characterize the expression and function of SFTA3 at the ocular surface and in tears. Ocular tissues, conjunctival (HCjE) and human corneal (HCE) epithelial cell lines as well as tearfilm of patients suffering from different forms of dry eye disease (DED) were analyzed by means of RT-PCR, western blot, immunohistochemistry, and ELISA. A possible role of recombinant SFTA3 in corneal wound healing was investigated performing in vitro scratch assays. Tear film regulatory properties were analyzed with the spinning drop method and the regulation of SFTA3 transcripts was studied in HCE and HCjE after incubation with proinflammatory cytokines as well as typical ocular pathogens by real-time RT-PCR and ELISA. The results reveal that human ocular tissue as well as tears of healthy volunteers express SFTA3 whereas tears from patients with DED showed significantly increased SFTA3 levels. In vitro wounding of HCE cell cultures that had been treated with recombinant SFTA3 demonstrated a significantly increased wound closure rate and rSFTA3 reduced the surface tension of tear fluid. The results indicate that SFTA3 at the ocular surface seemed to be involved in wound healing and the reduction of surface tension.

  16. Allergy and allergic mediators in tears.

    PubMed

    Leonardi, Andrea

    2013-12-01

    The identification of inflammatory mediators in the tear fluid have been extensively used in ocular allergy to find either a 'disease marker', to better understand the immune mechanisms involved in the ocular surface inflammation, or to identify potential targets for therapeutic interventions. While the clinical characteristics allow a relatively convincing diagnosis of ocular allergic diseases, in the initial, non active phases, or in the chronic stages, the diagnosis may not be clear. Although not highly specific, total tear IgE can be measured with local tests by inserting a paper strip in the lower meniscus. The measurement of tear specific inflammatory markers, such as histamine, tryptase, ECP, IL-4, IL-5 and eotaxin, may be useful for the diagnosis or monitoring ocular allergy. New technologies such as multiplex bead assays, membrane-bound antibody array and proteomic techniques can characterize the distribution of a wide range of bioactive trace proteins in tears. Dozens of mediators, cytokines, chemokines, growth factors, angiogenic modulators, enzymes and inhibitors were thus identified in small tear samples using these techniques, providing the possible identification of specific biomarker for either specific disease or disease activity. However, to date, there is no a single specific laboratory test suitable for the diagnosis and monitoring of allergic conjunctivitis. Copyright © 2013 Elsevier Ltd. All rights reserved.

  17. Biological and Clinical Implications of Lysozyme Deposition on Soft Contact Lenses

    PubMed Central

    Omali, Negar Babaei; Subbaraman, Lakshman N.; Coles-Brennan, Chantal; Fadli, Zohra; Jones, Lyndon W.

    2015-01-01

    ABSTRACT Within a few minutes of wear, contact lenses become rapidly coated with a variety of tear film components, including proteins, lipids, and mucins. Tears have a rich and complex composition, allowing a wide range of interactions and competitive processes, with the first event observed at the interface between a contact lens and tear fluid being protein adsorption. Protein adsorption on hydrogel contact lenses is a complex process involving a variety of factors relating to both the protein in question and the lens material. Among tear proteins, lysozyme is a major protein that has both antibacterial and anti-inflammatory functions. Contact lens materials that have high ionicity and high water content have an increased affinity to accumulate lysozyme during wear, when compared with other soft lens materials, notably silicone hydrogel lenses. This review provides an overview of tear film proteins, with a specific focus on lysozyme, and examines various factors that influence protein deposition on contact lenses. In addition, the impact of lysozyme deposition on various ocular physiological responses and bacterial adhesion to lenses and the interaction of lysozyme with other tear proteins are reviewed. This comprehensive review suggests that deposition of lysozyme on contact lens materials may provide a number of beneficial effects during contact lens wear. PMID:26002002

  18. Topical Application of Apricot Kernel Extract Improves Dry Eye Symptoms in a Unilateral Exorbital Lacrimal Gland Excision Mouse

    PubMed Central

    Kim, Chan-Sik; Jo, Kyuhyung; Lee, Ik-Soo; Kim, Junghyun

    2016-01-01

    The purpose of this study was to investigate the therapeutic effects of topical application of apricot kernel extract (AKE) in a unilateral exorbital lacrimal gland excision mouse model of experimental dry eye. Dry eye was induced by surgical removal of the lacrimal gland. Eye drops containing 0.5 or 1 mg/mL AKE were administered twice a day from day 3 to day 7 after surgery. Tear fluid volume and corneal irregularity scores were determined. In addition, we examined the immunohistochemical expression level of Muc4. The topical administration of AKE dose-dependently improved all clinical dry eye symptoms by promoting the secretion of tear fluid and mucin. Thus, the results of this study indicate that AKE may be an efficacious topical agent for treating dry eye disease. PMID:27886047

  19. Topical Application of Apricot Kernel Extract Improves Dry Eye Symptoms in a Unilateral Exorbital Lacrimal Gland Excision Mouse.

    PubMed

    Kim, Chan-Sik; Jo, Kyuhyung; Lee, Ik-Soo; Kim, Junghyun

    2016-11-23

    The purpose of this study was to investigate the therapeutic effects of topical application of apricot kernel extract (AKE) in a unilateral exorbital lacrimal gland excision mouse model of experimental dry eye. Dry eye was induced by surgical removal of the lacrimal gland. Eye drops containing 0.5 or 1 mg/mL AKE were administered twice a day from day 3 to day 7 after surgery. Tear fluid volume and corneal irregularity scores were determined. In addition, we examined the immunohistochemical expression level of Muc4. The topical administration of AKE dose-dependently improved all clinical dry eye symptoms by promoting the secretion of tear fluid and mucin. Thus, the results of this study indicate that AKE may be an efficacious topical agent for treating dry eye disease.

  20. Phospholipids and their degrading enzyme in the tears of soft contact lens wearers.

    PubMed

    Yamada, Masakazu; Mochizuki, Hiroshi; Kawashima, Motoko; Hata, Seiichiro

    2006-12-01

    Low tear phospholipids levels are associated with tear film instability in soft contact lens wearers. We assayed levels of phospholipids and their degrading enzyme secretory phospholipase A2 (sPLA2) both in tears and deposited on contact lenses composed of 2 hydrophilic materials after 1 day of routine use. Polymacon (Medalist; FDA group 1, low water/nonionic) and Etafilcon A (One Day Acuvue; group 4, high water/ionic) contact lenses were worn for 12 hours by 16 experienced contact lens wearers. Phospholipids in tear fluids and deposited on contact lenses were estimated by phosphorus determination with ammonium molybdate through enzymatic digestion. Double-antibody sandwich ELISA was used to determine group IIa sPLA2 concentrations, and sPLA2 activity was assayed using 1,2-diheptanoyl thio-phosphatidylcholine as substrate. Phospholipids concentrations in tears with Polymacon and Etafilcon A were 186 +/- 39 and 162 +/- 33 microg/mL, respectively. The latter concentration was significantly lower than that observed in the same subjects when not wearing contact lenses (P = 0.0023). In tears, both group IIa sPLA2 concentrations and enzymatic activity remained unchanged, regardless of lens wearing. However, Etafilcon A (0.57 +/- 0.09 microg/lens) showed more group IIa sPLA2 deposition than Polymacon (0.01 +/- 0.01 microg/lens; P < 0.001). Furthermore, group IIa sPLA2 deposited on Etafilcon A but not on Polymacon lenses retained its enzymatic activity. Significant differences of group IIa sPLA2 deposition were found in the 2 lenses tested. Such deposition might induce phospholipid hydrolysis in tears and thereby promote tear film instability in hydrophilic contact lens wearers.

  1. Characterization of synovial fluid cytokine profiles in chronic meniscal tear of the knee.

    PubMed

    Bigoni, Marco; Turati, Marco; Sacerdote, Paola; Gaddi, Diego; Piatti, Massimiliano; Castelnuovo, Alberto; Franchi, Silvia; Gandolla, Marta; Pedrocchi, Alessandra; Omeljaniuk, Robert J; Bresciani, Elena; Locatelli, Vittorio; Torsello, Antonio

    2017-02-01

    Concentrations of pro- and anti-inflammatory cytokines in synovial fluid samples collected from patients with chronic meniscal tears were investigated. An acute inflammatory response is generally reported 24-48 h after knee injury, but the largest body of data available in literature concerns anterior cruciate ligament injury and very little information is available about the balance of soluble factors in the synovial fluid of knees with chronic meniscal tears. Sixty-nine patients (46 males and 23 females) with meniscal tear that occurred more than 3 months earlier were enrolled. According to cartilage integrity assessment by arthroscopic examination, patients were assigned to one of the following groups: (i) no chondral damage (n = 18); (ii) chondral damage graded from I to II (n = 15); and (iii) chondral damage graded from III to IV (n = 37). In all groups, levels of IL-10 and inflammatory cytokines IL-6, TNF-α, and IL-8 where greater compared with those reported in the intact population; by contrast, levels of IL-1ra and IL-1β were significantly lower. Interestingly, IL-6 levels were higher in female than male patients. Cytokine levels did not correlate with degree of chondral damage. IL-6 and IL-1ra levels positively correlated with IL-1β, and negatively correlated with TNF-α. Interestingly, levels of IL-1β and TNF-α were inversely correlated. Our data demonstrate increased levels of pro-inflammatory cytokines (IL-6, IL-8, and TNF-α) in the chronic phase of meniscal trauma. This pro-inflammatory state is maintained in the joint from the time of initial injury to several months later and could be a key factor in hampering cartilage regeneration. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:340-346, 2017. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  2. On the Evolution of Pulsatile Flow Subject to a Transverse Impulse Body Force

    NASA Astrophysics Data System (ADS)

    di Labbio, Giuseppe; Keshavarz-Motamed, Zahra; Kadem, Lyes

    2014-11-01

    In the event of an unexpected abrupt traffic stop or car accident, automotive passengers will experience an abrupt body deceleration. This may lead to tearing or dissection of the aortic wall known as Blunt Traumatic Aortic Rupture (BTAR). BTAR is the second leading cause of death in automotive accidents and, although quite frequent, the mechanisms leading to BTAR are still not clearly identified, particularly the contribution of the flow field. As such, this work is intended to provide a fundamental framework for the investigation of the flow contribution to BTAR. In this fundamental study, pulsatile flow in a three-dimensional, straight pipe of circular cross-section is subjected to a unidirectional, transverse, impulse body force applied on a strictly bounded volume of fluid. These models were simulated using the Computational Fluid Dynamics (CFD) software FLUENT. The evolution of fluid field characteristics was investigated during and after the application of the force. The application of the force significantly modified the flow field. The force induces a transverse pressure gradient causing the development of secondary flow structures that dissipate the energy added by the acceleration. Once the force ceases to act, these structures are carried downstream and gradually dissipate their excess energy.

  3. Verification of long wavelength electromagnetic modes with a gyrokinetic-fluid hybrid model in the XGC code

    PubMed Central

    Lang, Jianying; Ku, S.; Chen, Y.; Parker, S. E.; Adams, M. F.

    2017-01-01

    As an alternative option to kinetic electrons, the gyrokinetic total-f particle-in-cell (PIC) code XGC1 has been extended to the MHD/fluid type electromagnetic regime by combining gyrokinetic PIC ions with massless drift-fluid electrons analogous to Chen and Parker [Phys. Plasmas 8, 441 (2001)]. Two representative long wavelength modes, shear Alfvén waves and resistive tearing modes, are verified in cylindrical and toroidal magnetic field geometries. PMID:29104419

  4. First results of coupled IPS/NIMROD/GENRAY simulations

    NASA Astrophysics Data System (ADS)

    Jenkins, Thomas; Kruger, S. E.; Held, E. D.; Harvey, R. W.; Elwasif, W. R.; Schnack, D. D.

    2010-11-01

    The Integrated Plasma Simulator (IPS) framework, developed by the SWIM Project Team, facilitates self-consistent simulations of complicated plasma behavior via the coupling of various codes modeling different spatial/temporal scales in the plasma. Here, we apply this capability to investigate the stabilization of tearing modes by ECCD. Under IPS control, the NIMROD code (MHD) evolves fluid equations to model bulk plasma behavior, while the GENRAY code (RF) calculates the self-consistent propagation and deposition of RF power in the resulting plasma profiles. GENRAY data is then used to construct moments of the quasilinear diffusion tensor (induced by the RF) which influence the dynamics of momentum/energy evolution in NIMROD's equations. We present initial results from these coupled simulations and demonstrate that they correctly capture the physics of magnetic island stabilization [Jenkins et al, PoP 17, 012502 (2010)] in the low-beta limit. We also discuss the process of code verification in these simulations, demonstrating good agreement between NIMROD and GENRAY predictions for the flux-surface-averaged, RF-induced currents. An overview of ongoing model development (synthetic diagnostics/plasma control systems; neoclassical effects; etc.) is also presented. Funded by US DoE.

  5. Comparing magnetic fluctuation dynamics in nonlinear MHD simulations of low-aspect-ratio RFPs to RELAX experiments

    NASA Astrophysics Data System (ADS)

    McCollam, K. J.; den Hartog, D. J.; Jacobson, C. M.; Sovinec, C. R.; Masamune, S.; Sanpei, A.

    2017-10-01

    We present comparisons of magnetic tearing fluctuation activity between RFP experiments on the low-aspect-ratio RELAX device (R / a 2) and nonlinear simulations of zero-beta, single-fluid MHD using the NIMROD code in both cylindrical and toroidal geometries at a Lundquist number of S =104 , nearly as high as experimental values. Time-average fluctuation amplitudes observed in the simulations are similar to those from the experiments, but more rigorous comparisons versus spectral mode numbers are in progress. We also focus on how the spatiotemporal dynamics of the fluctuations vary with RFP equilibrium parameters. Interestingly, at shallow reversal, cylindrical simulations show a relatively uncoupled spectrum of nearly quiescent modes periodically varying in time, whereas the corresponding toroidal cases show a fully chaotic spectrum of strongly nonlinearly interacting modes. We ascribe this to the geometric m = 1 coupling present in the toroidal but not the cylindrical case. We present initial results from convergence studies with increased spatial resolution for both geometries. Simulations at higher S are planned. This work is supported by the U.S. DOE and by the Japan Society for the Promotion of Science.

  6. Forced tearing of ductile and brittle thin sheets.

    PubMed

    Tallinen, T; Mahadevan, L

    2011-12-09

    Tearing a thin sheet by forcing a rigid object through it leads to complex crack morphologies; a single oscillatory crack arises when a tool is driven laterally through a brittle sheet, while two diverging cracks and a series of concertinalike folds forms when a tool is forced laterally through a ductile sheet. On the other hand, forcing an object perpendicularly through the sheet leads to radial petallike tears in both ductile and brittle materials. To understand these different regimes we use a combination of experiments, simulations, and simple theories. In particular, we describe the transition from brittle oscillatory tearing via a single crack to ductile concertina tearing with two tears by deriving laws that describe the crack paths and wavelength of the concertina folds and provide a simple phase diagram for the morphologies in terms of the material properties of the sheet and the relative size of the tool.

  7. Glycomic characterization of basal tears and changes with diabetes and diabetic retinopathy.

    PubMed

    Nguyen-Khuong, Terry; Everest-Dass, Arun V; Kautto, Liisa; Zhao, Zhenjun; Willcox, Mark D P; Packer, Nicolle H

    2015-03-01

    As a secreted fluid, the state of tear glycosylation is particularly important in the role of immunity of the ocular surface. Tears are a valuable source of non-invasive biomarkers for disease and there are continued efforts to characterize their components thoroughly. In this study, a small volume of basal tears (5 μL) was collected from healthy controls, patients with diabetes without retinopathy and patients with diabetes and retinopathy. The detailed N- and O-linked tear protein glycome was characterized and the relative abundance of each structure determined. Of the 50 N-linked glycans found, 89% were complex with 50% containing a bisecting N-acetylglucosamine, 65% containing a core fucose whilst 33% were sialylated. Of the 8 O-linked glycans detected, 3 were of cores 1 and 5 of core 2 type, with a majority of them being sialylated (90%). Additionally, these glycan structures were profiled across the three diabetic disease groups. Whilst the higher abundant structures did not alter across the three groups, only five low abundance N-linked glycans and 1 O-linked glycan did alter with the onset of diabetes mellitus and diabetic retinopathy (DR). These results suggest the conservation of glycan types on basal tear proteins between individuals and point to only small changes in glycan expression on the proteins in tears with the development of diabetes and DR. © The Author 2014. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  8. Tear Film Steroid Profiling in Dry Eye Disease by Liquid Chromatography Tandem Mass Spectrometry

    PubMed Central

    Agnifili, Luca; Cicalini, Ilaria; Calienno, Roberta; Zucchelli, Mirco; Mastropasqua, Leonardo; Sacchetta, Paolo; Del Boccio, Piero; Rossi, Claudia

    2017-01-01

    Dry eye disease (DED) is a multifactorial disorder of the ocular surface unit resulting in eye discomfort, visual disturbance, and ocular surface damage; the risk of DED increases with age in both sexes, while its incidence is higher among females caused by an overall hormonal imbalance. The role of androgens has recently investigated and these hormones were considered to have a protective function on the ocular surface. In order to correlate DED to tear steroid levels, a robust, specific, and selective method for the simultaneous quantification of cortisol (CORT), corticosterone (CCONE), 11-deoxycortisol (11-DECOL), 4-androstene-3,17-dione (ADIONE), testosterone (TESTO), 17α-hydroxyprogesterone (17-OHP), and progesterone (PROG) was developed and applied for the analysis of tear samples. The method involves a simple extraction procedure of steroids from tears collected on Schirmer strips, followed by a high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) analysis. In total, tear samples from 14 DED female patients and 13 healthy female controls were analysed and, CORT, ADIONE, and 17-OHP response levels resulted significantly decreased in dry eye patients respect to controls. The receiver operating characteristic (ROC) curve obtained by the combination of these three steroids (AUC = 0.964) demonstrated the good diagnostic power of the differential tear steroids in identifying DED. In conclusion, the present method made it possible, for the first time, to study steroid profiling directly in tear fluid. PMID:28672794

  9. Long-term results of repeated anti-vascular endothelial growth factor therapy in eyes with retinal pigment epithelial tears.

    PubMed

    Moreira, Carlos A; Arana, Luis A; Zago, Rommel J

    2013-02-01

    To evaluate the long-term results of retinal pigment epithelium tears in eyes treated with repeated anti-vascular endothelial growth factor (VEGF) therapy. Five patients with retinal pigment epithelial tears (without foveal center involvement) after anti-VEGF injection were studied retrospectively. Mean follow-up time was 52 months, with measurements of visual acuity and evaluation of macular findings by angiography and optical coherence tomography during this period. All eyes had a persistent submacular neovascular membrane 30 days after the tear. An anti-VEGF drug was reinjected until the membranes stopped leaking. The mean initial visual acuity immediately after the tear was 20/160, and the mean final visual acuity was 20/60. The number of anti-VEGF reinjections varied from two to eight during the follow-up period. Long-term optical coherence tomography analysis showed reduced fluid and remodeling of the torn retinal pigment epithelium. Long-term visual results with repeated anti-VEGF therapy are not as devastating as suggested previously. Visual acuity and metamorphopsia improve with time as long as the neovascular membrane is inactive. Optical coherence tomography changes in the macular area reflect the visual acuity improvement.

  10. Immunomodulatory effect of the topical ophthalmic Janus kinase inhibitor tofacitinib (CP-690,550) in patients with dry eye disease.

    PubMed

    Huang, Jing-Feng; Yafawi, Rolla; Zhang, Min; McDowell, Michael; Rittenhouse, Kay D; Sace, Frederick; Liew, Shiao Hui Melissa; Cooper, Scott R; Pickering, Eve H

    2012-07-01

    To evaluate the immunomodulatory effect of topical ophthalmic tofacitinib (CP-690,550) after an 8-week treatment period in patients with dry eye disease (DED). Biomarker substudy of a phase 1/2 prospective, randomized, vehicle- and comparator-controlled clinical trial (NCT00784719). A total of 82 patients with moderate to severe DED enrolled. Patients received 1 of 5 doses of tofacitinib (0.0003%, 0.001%, 0.003%, or 0.005% twice daily [BID] or 0.005% once daily [QD]), active comparator (cyclosporine ophthalmic emulsion, 0.05% [Restasis, Allergan Inc., Irvine, CA]), or vehicle control BID for 8 weeks. Conjunctival impression cytology and tear fluid samples were collected at baseline and after an 8-week treatment period. Conjunctival cells were analyzed by flow cytometry for human leukocyte antigen DR-1 (HLA-DR). Tear fluids were analyzed by microsphere-based immunoassays for tear levels of cytokines and inflammation markers. Reduction in inflammation assessed by change from baseline in conjunctival cell surface level of HLA-DR and tear level of cytokines and inflammation markers. At week 8, a decrease in conjunctival cell surface expression of HLA-DR was observed in patients treated with tofacitinib 0.005% QD and 0.003% BID: 71% and 67% of baseline, respectively, compared with 133% of baseline in patients treated with vehicle (P=0.023 and P=0.006, compared with vehicle, respectively). Matrix metalloproteinase (MMP)-3 in tears was reduced from baseline at week 8 (40% of baseline, P=0.035) in the tofacitinib 0.005% QD group, whereas the vehicle group showed 77% of baseline (P>0.20). Interleukin (IL)-1β in tears was 36% of baseline (P=0.053) in the tofacitinib 0.005% QD group and 95% of baseline (P > 0.20) in the vehicle group. Several other cytokines and inflammation markers in tears, including MMP-9, IL-15, IL-17A, and IL-12p70, were markedly reduced in the tofacitinib 0.005% QD group but not the vehicle group. There was an association between the changes in HLA-DR and the tear inflammation markers (P<0.05): HLA-DR with IL-12p70 (r=0.49) and IL-1β (r=0.46), IL-12p70 with IL-1β (r=0.90), and IL-17A with MMP-9 (r=0.82). Topical ophthalmic tofacitinib may act as an immunomodulator in patients with DED. Treatment for 8 weeks showed a promising reduction of conjunctival cell surface HLA-DR expression and tear levels of proinflammatory cytokines and inflammation markers. Copyright © 2012 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  11. [Development of non-invasive clinical examination methods for the anterior segment of the eye and their clinical significance].

    PubMed

    Sawa, Mitsuru

    2011-03-01

    1. Slit-lamp microscopy is a principal ophthalmic clinical method, because it provides microscopic findings of the anterior segment of the eye noninvasively. Its findings, however, are qualitative and there are large inter-observer variations in their evaluation. Furthermore, slit-lamp microscopy provides morphological findings, but a functional evaluation is difficult. We developed two novel methods that establish a qualitative methodology of the slit-lamp microscope and the pathophysiology of the anterior segment of the eye. One is the flare-cell photometer to evaluate flare and cells in the aqueous humor of the eye and the other is an immunohistochemical examination method using tear fluid to evaluate ocular surface disorders. The comprehensive evaluation of these studies is herein overviewed. 2. INNOVATION OF THE FLARE-CELL PHOTOMETER AND ITS CLINICAL SIGNIFICANCE: The breakdown of the blood-aqueous barrier (BAB) causes an increase in protein (flare) and leakage of blood cells (cell) into the aqueous humor of the eye and the severity of BAB breakdown has a positive correlation with the intensity of flare and cells. The flare and cells in the aqueous can be observed qualitatively by slit-lamp microscopy. These findings are primarily distinguished in optics by light scattering. Therefore, detection of the intensity of light scattering due to flare and cells can evaluate the BAB function. The flare-cell photometer comprises 3 novel components: a laser beam system as an incident light, a photomultiplier to detect scattered light intensity and a computer-assisted system to operate the whole system and analyze detected scattered light signals due to flare and cells. The instrument enables us to quantitatively analyze the flare and cells non-invasively and accurately with a wide dynamic measurement range, resulting in a repeated examination of each individual case. It also enables the evaluation of inflammation in the aqueous not only postoperatively but also in endogenous uveitis, evaluation of the effects of anti-inflammatory drugs on BAB and evaluation of aqueous humor dynamics. Furthermore, repeating the examination can minimize inter-individual variations and reduce the number of animals in animal experiments. 3. Sampling of tears can be performed noninvasively, but the obtainable volume is limited. Therefore, a determination of targeting biomarkers and a development of their micro-volume analysis methods play a crucial role in pathophysiological studies of the ocular surface. Targeting biomarkers should be determined according to the various specified bioactive substances such as eosinophil cationic protein (ECP), cytokines and others. A number of microvolume analysis methods, such as chemiluminescent enzyme immunoassay, immunochromatography, micro-array system and polymerase chain reaction method are used. Objective disorders in the studies include allergic conjunctivitis and infectious diseases such as herpetic keratitis. Quantitative evaluation methods for ECP concentration, antigen-specific secretory IgA in allergic diseases and herpetic keratitis, herpes simplex virus-DNA and cytokine and chemokine profile in tear fluid sampled by filter paper method were investigated. We developed a clinically applicable quantitative immunochemical method for ECP concentration in tear fluid. The results revealed that tear fluid analysis using the above mentioned methods is a clinically useful to investigate the pathophysiology of the ocular surface. 4. Laser flare-cell photometer and tear fluid analysis are potent clinical quantitative methods to investigate the pathophysiology of the anterior segment of the eye.

  12. Materials science of the gel to fluid phase transition in a supported phospholipid bilayer.

    PubMed

    Xie, Anne Feng; Yamada, Ryo; Gewirth, Andrew A; Granick, Steve

    2002-12-09

    We report the results of in situ AFM measurements examining the phase transition of bilayers formed from the zwitterionic phospholipid, DMPC, 1,2-dimyristoyl-sn-glycero-3-phosphocholine, supported on mica. The images show that the fluid to gel phase transition process features substantial tearing of the bilayer due to the density change between the two phases. The gel to fluid transition is strongly affected by the resultant stress introduced into the gel phase, which changes the degree of cooperativity, the shape of developing fluid phase regions, and the course of the transition.

  13. Gyrokinetic δ f simulation of collisionless and semi-collisional tearing mode instabilities

    NASA Astrophysics Data System (ADS)

    Wan, Weigang; Chen, Yang; Parker, Scott

    2004-11-01

    The evolution of collisionless and semi-collisional tearing mode instabilities is studied using a three-dimensional particle-in-cell simulation model that utilizes the δ f-method with the split-weight scheme to enhance the time step, and a novel algorithm(Y. Chen and S.E. Parker, J. Comput. Phys. 198), 463 (2003) to accurately solve the Ampere's equation for experimentally relevant β values, βfracm_im_e≫ 1. We use the model of drift-kinetic electrons and gyrokinetic ions. Linear simulation results are benchmarked with eigenmode analysis for the case of fixed ions. In small box simulations the ions response can be neglected but for large box simulations the ions response is important because the width of perturbed current is larger than ρ_i.The nonlinear dynamics of magnetic islands will be studied and the results will be compared with previous theoretical studiesfootnote J.F. Drake and Y. C. Lee, Phys. Rev. Lett. 39, 453 (1977) on the saturation level and the electron bounce frequency. A collision operator is included in the electron drift kinetic equation to study the simulation in the semi-collisional regime. The algebraical growth stage has been observed and compared quantitatively with theory. Our progress on three-dimensional simulations of tearing mode instabilities will be reported.

  14. Wearable smart sensor systems integrated on soft contact lenses for wireless ocular diagnostics

    PubMed Central

    Kim, Joohee; Kim, Minji; Lee, Mi-Sun; Kim, Kukjoo; Ji, Sangyoon; Kim, Yun-Tae; Park, Jihun; Na, Kyungmin; Bae, Kwi-Hyun; Kyun Kim, Hong; Bien, Franklin; Young Lee, Chang; Park, Jang-Ung

    2017-01-01

    Wearable contact lenses which can monitor physiological parameters have attracted substantial interests due to the capability of direct detection of biomarkers contained in body fluids. However, previously reported contact lens sensors can only monitor a single analyte at a time. Furthermore, such ocular contact lenses generally obstruct the field of vision of the subject. Here, we developed a multifunctional contact lens sensor that alleviates some of these limitations since it was developed on an actual ocular contact lens. It was also designed to monitor glucose within tears, as well as intraocular pressure using the resistance and capacitance of the electronic device. Furthermore, in-vivo and in-vitro tests using a live rabbit and bovine eyeball demonstrated its reliable operation. Our developed contact lens sensor can measure the glucose level in tear fluid and intraocular pressure simultaneously but yet independently based on different electrical responses. PMID:28447604

  15. Wearable smart sensor systems integrated on soft contact lenses for wireless ocular diagnostics.

    PubMed

    Kim, Joohee; Kim, Minji; Lee, Mi-Sun; Kim, Kukjoo; Ji, Sangyoon; Kim, Yun-Tae; Park, Jihun; Na, Kyungmin; Bae, Kwi-Hyun; Kyun Kim, Hong; Bien, Franklin; Young Lee, Chang; Park, Jang-Ung

    2017-04-27

    Wearable contact lenses which can monitor physiological parameters have attracted substantial interests due to the capability of direct detection of biomarkers contained in body fluids. However, previously reported contact lens sensors can only monitor a single analyte at a time. Furthermore, such ocular contact lenses generally obstruct the field of vision of the subject. Here, we developed a multifunctional contact lens sensor that alleviates some of these limitations since it was developed on an actual ocular contact lens. It was also designed to monitor glucose within tears, as well as intraocular pressure using the resistance and capacitance of the electronic device. Furthermore, in-vivo and in-vitro tests using a live rabbit and bovine eyeball demonstrated its reliable operation. Our developed contact lens sensor can measure the glucose level in tear fluid and intraocular pressure simultaneously but yet independently based on different electrical responses.

  16. Wearable smart sensor systems integrated on soft contact lenses for wireless ocular diagnostics

    NASA Astrophysics Data System (ADS)

    Kim, Joohee; Kim, Minji; Lee, Mi-Sun; Kim, Kukjoo; Ji, Sangyoon; Kim, Yun-Tae; Park, Jihun; Na, Kyungmin; Bae, Kwi-Hyun; Kyun Kim, Hong; Bien, Franklin; Young Lee, Chang; Park, Jang-Ung

    2017-04-01

    Wearable contact lenses which can monitor physiological parameters have attracted substantial interests due to the capability of direct detection of biomarkers contained in body fluids. However, previously reported contact lens sensors can only monitor a single analyte at a time. Furthermore, such ocular contact lenses generally obstruct the field of vision of the subject. Here, we developed a multifunctional contact lens sensor that alleviates some of these limitations since it was developed on an actual ocular contact lens. It was also designed to monitor glucose within tears, as well as intraocular pressure using the resistance and capacitance of the electronic device. Furthermore, in-vivo and in-vitro tests using a live rabbit and bovine eyeball demonstrated its reliable operation. Our developed contact lens sensor can measure the glucose level in tear fluid and intraocular pressure simultaneously but yet independently based on different electrical responses.

  17. [The peroxidase content of human tears].

    PubMed

    Buchberger, W; Rieger, G

    1989-01-01

    The peroxidase-(POD)-thiocyanate-hydrogenperoxide-system is a well-known antibacterial system, which has been demonstrated to exist, for example, in milk and saliva. Earlier investigations by van Haeringen et al. established a POD level in human tears of 10(3) units/l, yet the thiocyanate concentration was only about 0.2 mmol/l. Therefore van Haeringen et al. excluded the existence of a POD-thiocyanate-hydrogenperoxide antibacterial system in human tears because of the insufficient amount of thiocyanate in the tears examined. Instead of thiocyanate halides such as J- can also complete the POD hydrogen peroxide system as electron donors. Sufficient amounts of iodide can be expected after the application of iodine-containing eye drops or after local treatment with iodine-containing brine, as done in Bad Hall in Austria. Therefore, the above mentioned antibacterial system may be of importance if the POD-level is high enough (greater than 250 units/l). We investigated 22 tear samples from healthy persons: the POD levels were below 20 units/l in 19 cases; in 3 cases the POD concentration was found to be between 20 and 50 units/l. Therefore, in normal human tear fluid, not only the amount of thiocyanate but also the concentration of POD is too low for effective antimicrobial activity of the peroxidase-thiocyanate-hydrogenperoxide system. It is so far not known whether this system is effective under pathological conditions.

  18. Changes in the ocular and nasal signs and symptoms of aircrews in relation to the ban on smoking on intercontinental flights.

    PubMed

    Wieslander, G; Lindgren, T; Norbäck, D; Venge, P

    2000-12-01

    This study determined the influence of exposure to environmental tobacco smoke (ETS) in aircraft on measured and perceived cabin air quality (CAQ), symptoms, tear-film stability, nasal patency, and biomarkers in nasal lavage fluid. Commercial aircrews underwent a standardized examination, including acoustic rhinometry, nasal lavage, and measurement of tear-film break-up time. Eosinophilic cationic protein, myeloperoxidase, lysozyme, and albumin were analyzed in the nasal lavage fluid. Inflight investigations [participation rate 98% (N=39)] were performed on board 4 flights, 2 in each direction between Scandinavia and Japan. Scandinavian crew on 6 flights from Scandinavia to Japan participated in postflight measurements after landing [participation rate 85% (N=41)]. Half the flights permitted smoking on board, and the other half, 0.5 months later, did not. Hygienic measurements showed low relative air humidity on board (2-10%) and a carbon dioxide concentration of <1000 ppm during 99.6% of the cruising time. The smoking ban caused a drastic reduction of respirable particles, from a mean of 66 (SD 56) microg/m3 to 3 (SD 0.8) microg/m3. The perceived CAQ was improved, and there were fewer symptoms, particularly ocular symptoms, headache and tiredness. Tear-film stability increased, and nasal patency was altered. Despite a high air exchange rate and spatial separation between smokers and nonsmokers, smoking in commercial aircraft may cause significant air pollution, as indicated by a large increase in respirable particles. This ETS exposure is associated with an increase in ocular and general symptoms, decreased tear-film stability, and alterations of nasal patency.

  19. Concentrations of MUC16 and MUC5AC using three tear collection methods

    PubMed Central

    Nichols, Jason J.

    2017-01-01

    Purpose To determine the optimal tear collection method for analysis of ocular surface mucins MUC5AC and MUC16. Methods Fifteen subjects without ocular surface disease were recruited. Subjects presented for tear collection on three separate days for three different tear collection methods with the order of method randomized. Methods used to collect tears from right and left eyes included Schirmer’s strip, basal tear collection, and flush tear collection. All samples from the right eyes were individually analyzed for MUC5AC whereas the left eye samples were individually analyzed for MUC16. For each individual sample, 10 μg of protein were loaded per lane into a 1% (w/v) agarose gel and run in electrophoresis buffer for 2 h. After overnight capillary transfer, membranes were incubated with either MUC5AC antibody CLH2 or MUC16 antibody OC125 for western blot analysis. Blots were developed with enhanced chemiluminescence (ECL) and signals captured with the Odyssey Fc (LI-COR). The relative amounts of MUC5AC and MUC16 were quantified with densitometry using software and compared for statistically significant differences between tear collection methods using the Kruskal–Wallis test in SPSS 22 and GraphPad Prism 7.02. Dunn’s multiple comparisons test was used for pairwise post-hoc comparisons. Results Samples containing less than 10 μg of total protein were not used for analysis which left eight samples (out of 45) unusable. The calculated MUC5AC median signal intensities from Schirmer’s strip, basal tears, and flush tears were 2.86 (n = 15, the interquartile range [IQR] = 2.54–3.21), 1.65 (n = 14, IQR = 1.34–3.1), and 1.67 (n = 9, IQR = 1.42–1.72), respectively (H = 9.5, p = 0.009). Post-hoc pairwise comparisons showed a statistically significant difference between Schirmer’s strip and flush tears (p = 0.01). The calculated MUC16 median signal intensities from Schirmer’s strip, basal tears, and flush tears were 1.88 (n = 14, IQR = 1.43–2.61), 5.24 (n = 15, IQR = 4.16–6.21), and 2.45 (n = 7, IQR = 1.85–2.48), respectively (H = 18.1, p = 0.001). Post-hoc pairwise comparison showed statistically significant differences between basal tears and Schirmer’s strip (p = 0.0003) and between basal tears and flush tears (p = 0.006). Conclusions MUC5AC and MUC16 are present in human tear fluid and can be captured using various tear collection methods. Although basal tear collection yielded the highest relative concentration of MUC16, Schirmer’s strip tear collection yielded the highest MUC5AC concentration. Therefore, the tear collection method chosen depends on the mucin of interest. PMID:28761326

  20. Influence of magnetic flutter on tearing growth in linear and nonlinear theory

    NASA Astrophysics Data System (ADS)

    Kreifels, L.; Hornsby, W. A.; Weikl, A.; Peeters, A. G.

    2018-06-01

    Recent simulations of tearing modes in turbulent regimes show an unexpected enhancement in the growth rate. In this paper the effect is investigated analytically. The enhancement is linked to the influence of turbulent magnetic flutter, which is modelled by diffusion terms in magnetohydrodynamics (MHD) momentum balance and Ohm’s law. Expressions for the linear growth rate as well as the island width in nonlinear theory for small amplitudes are derived. The results indicate an enhanced linear growth rate and a larger linear layer width compared with resistive MHD. Also the island width in the nonlinear regime grows faster in the diffusive model. These observations correspond well to simulations in which the effect of turbulence on the magnetic island width and tearing mode growth is analyzed.

  1. In-vitro analysis of the microbicidal activity of 6 contact lens care solutions

    PubMed Central

    2012-01-01

    Background Contact lens-related infections are often associated with inadequate contact lens hygiene, and therefore, contact lens care products should be able to sufficiently minimise the amount of pathogens that are responsible for these infections. In 2001, the EN ISO 14729 was introduced to ensure adequate disinfection efficacy of contact lens care solutions, but this norm has recently been criticised. Methods In this study, six frequently used contact lens care solutions were retested according to the Stand Alone Test of the EN ISO 14729 (2001). The Stand Alone Test is a quantitative suspension test. In addition, the products were tested in a modified setting adding an organic load. The load was a mixture of human blood serum, lysozyme, and mucine, which resembles tear fluid. Results The criteria of the Stand Alone Test recommended in EN ISO 14729 were only met by Aosept Plus. This 3% hydrogen-peroxide-based contact lens care solution attained a reduction factor of > 5 log units for bacteria and > 4 for fungi in all cases. Two further contact lens care solutions, Blue Vision and Optifree Replenish, met the criteria of a reduction factor of > 3 log units for bacteria and > 1 log unit for fungi, but only in the presence of artificial tear fluid. The three remaining products did not exhibit adequate disinfecting efficacy, at least against one of the tested microorganisms. Conclusions Through the observation that the artificial tear fluid used in this study influences the disinfecting efficacy of contact lens care solutions, especially that of multi-purpose solutions, in a different way than does albumin, mucine, or even the organic load suggested in EN ISO 14729, it becomes obvious that the test conditions in the EN ISO 14729 should be revised in order to create more realistic conditions, e.g., by using a more realistic artificial tear fluid. Furthermore, we suggest adapting the EN ISO 14729 to the European test hierarchy for chemical disinfectants and antiseptics, which consists of three test phases and also requests meeting stricter criteria in order to pass the test. Unless the test conditions guarantee a sufficient reduction of potential pathogens, the risk of contact lens-related microbial keratitis and other infections will remain for the users. PMID:23033880

  2. Nonlinear dynamics of toroidal Alfvén eigenmodes in presence of tearing modes

    NASA Astrophysics Data System (ADS)

    Zhu, Jia; Ma, Zhiwei; Wang, Sheng; Zhang, Wei

    2016-10-01

    A new hybrid kinetic-MHD code CLT-K is developed to study nonlinear dynamics of n =1 toroidal Alfvén eigenmodes (TAEs) with the m/n =2/1 tearing mode. It is found that the n =1 TAE is first excited by isotropic energetic particles in the earlier stage and reaches the steady state due to wave-particle interaction. After the saturation of the n =1 TAE, the tearing mode intervenes and triggers the second growth of the mode. The modes goes into the second steady state due to multiple tearing mode-mode nonlinear coupling. Both wave-particle and wave-wave interactions are observed in our hybrid simulation.

  3. Fluid equations in the presence of electron cyclotron current drive

    NASA Astrophysics Data System (ADS)

    Jenkins, Thomas G.; Kruger, Scott E.

    2012-12-01

    Two-fluid equations, which include the physics imparted by an externally applied radiofrequency source near electron cyclotron resonance, are derived in their extended magnetohydrodynamic forms using the formalism of Hegna and Callen [Phys. Plasmas 16, 112501 (2009)]. The equations are compatible with the closed fluid/drift-kinetic model developed by Ramos [Phys. Plasmas 17, 082502 (2010); 18, 102506 (2011)] for fusion-relevant regimes with low collisionality and slow dynamics, and they facilitate the development of advanced computational models for electron cyclotron current drive-induced suppression of neoclassical tearing modes.

  4. Fluid equations in the presence of electron cyclotron current drive

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jenkins, Thomas G.; Kruger, Scott E.

    Two-fluid equations, which include the physics imparted by an externally applied radiofrequency source near electron cyclotron resonance, are derived in their extended magnetohydrodynamic forms using the formalism of Hegna and Callen [Phys. Plasmas 16, 112501 (2009)]. The equations are compatible with the closed fluid/drift-kinetic model developed by Ramos [Phys. Plasmas 17, 082502 (2010); 18, 102506 (2011)] for fusion-relevant regimes with low collisionality and slow dynamics, and they facilitate the development of advanced computational models for electron cyclotron current drive-induced suppression of neoclassical tearing modes.

  5. Partial entropic stabilization of lattice Boltzmann magnetohydrodynamics

    NASA Astrophysics Data System (ADS)

    Flint, Christopher; Vahala, George

    2018-01-01

    The entropic lattice Boltzmann algorithm of Karlin et al. [Phys. Rev. E 90, 031302 (2014), 10.1103/PhysRevE.90.031302] is partially extended to magnetohydrodynamics, based on the Dellar model of introducing a vector distribution for the magnetic field. This entropic ansatz is now applied only to the scalar particle distribution function so as to permit the many problems entailing magnetic field reversal. A 9-bit lattice is employed for both particle and magnetic distributions for our two-dimensional simulations. The entropic ansatz is benchmarked against our earlier multiple relaxation lattice-Boltzmann model for the Kelvin-Helmholtz instability in a magnetized jet. Other two-dimensional simulations are performed and compared to results determined by more standard direct algorithms: in particular the switch over between the Kelvin-Helmholtz or tearing mode instability of Chen et al. [J. Geophys. Res.: Space Phys. 102, 151 (1997), 10.1029/96JA03144], and the generalized Orszag-Tang vortex model of Biskamp-Welter [Phys. Fluids B 1, 1964 (1989), 10.1063/1.859060]. Very good results are achieved.

  6. Punctal plugs versus artificial tears for treating dry eye: a comparative observation of their effects on contrast sensitivity.

    PubMed

    Qiu, Weiqiang; Liu, Ziyuan; Zhang, Zhihong; Ao, Mingxin; Li, Xuemin; Wang, Wei

    2012-01-01

    This study aimed to compare the effects of treatment with punctal plugs versus artificial tears on visual function and tear film stability for dry eye. A total of 56 consecutive eyes of 28 dry eye patients observed at our clinic from May to October in 2009 were divided into two groups. One group (32 eyes of 16 patients) was treated with artificial tears, and punctal plugs were used in the other group (24 eyes of 12 patients). A questionnaire was used in these patients before treatment and was repeated 2 weeks after treatment. Fluorescent staining for tear film break-up time (BUT), the Schirmer test I (STI), and contrast sensitivity was performed at the same time. The questionnaire indicated that all patients complained about the uncomfortable symptoms associated with dry eye. These symptoms were relieved after the application of artificial tears or punctal plugs, and there was no significant difference between these two groups. We found that the corneal fluorescent staining disappeared after treatment. The BUT was improved significantly after treatment in both groups, but the improvement was greater in patients who received punctal plugs than those that received artificial tears. There was no remarkable change in the STI in the artificial tears group, but a significant change was observed in the punctal plugs group. The contrast sensitivities were greatly improved in simulated daylight, night, and glare disability conditions after treatment with artificial tears and punctal plugs. However, the changes in contrast sensitivity did not significantly differ between groups. Both artificial tears and punctal plugs relieved dry eye symptoms, repaired corneal lesions, enhanced tear film stability, and improved contrast sensitivity. Punctal plugs could improve tear film stability and elongate the BUT better than artificial tears.

  7. Noninvasive Diagnostic Devices for Diabetes through Measuring Tear Glucose

    PubMed Central

    Zhang, Jin; Hodge, William; Hutnick, Cindy; Wang, Xianbin

    2011-01-01

    This article reviews the development of a noninvasive diagnostic for diabetes by detecting ocular glucose. Early diagnosis and daily management are very important to diabetes patients to ensure a healthy life. Commercial blood glucose sensors have been used since the 1970s. Millions of diabetes patients have to prick their finger for a drop of blood 4–5 times a day to check blood glucose levels—almost 1800 times annually. There is a strong need to have a noninvasive device to help patients to manage the disease easily and painlessly. Instead of detecting the glucose in blood, monitoring the glucose level in other body fluids may provide a feasible approach for noninvasive diagnosis and diabetes control. Tear glucose has been studied for several decades. This article reviews studies on ocular glucose and its monitoring methods. Attempts to continuously monitor the concentration of tear glucose by using contact lens-based sensors are discussed as well as our current development of a nanostructured lens-based sensor for diabetes. This disposable biosensor for the detection of tear glucose may provide an alternative method to help patients manage the disease conveniently. PMID:21303640

  8. Clinical utility of 3% diquafosol ophthalmic solution in the treatment of dry eyes

    PubMed Central

    Koh, Shizuka

    2015-01-01

    Diquafosol is a drug used for dry eye treatment with a novel mechanism of action. It stimulates the secretion of tear fluid and mucin on the ocular surface, thus enabling us to selectively treat the tear film layer, playing an important role in the establishment of the concept of “Tear Film Oriented Therapy (TFOT)”, an effective therapeutic approach to dry eye in Japan. The 3% diquafosol ophthalmic solution has been widely used for the treatment of dry eye in clinical practice, and it is currently available in Japan and South Korea. This review provides an overview of the clinical utility of 3% diquafosol ophthalmic solution, focusing on the results of clinical studies on various types of dry eye, including aqueous-deficient dry eye, short tear film breakup time-type dry eye, and post dry eye after laser in situ keratomileusis. It also introduces the additive effect of diquafosol on sodium hyaluronate monotherapy for dry eye, and the effect of 3% diquafosol ophthalmic solution for dry eye-related conditions. Additionally, it summarizes the ocular effects of diquafosol in healthy human eyes. Lastly, the importance of improving tear film stability in dry eye treatment, as well as general advances in dry eye treatments, are described. PMID:26028958

  9. Clinical utility of 3% diquafosol ophthalmic solution in the treatment of dry eyes.

    PubMed

    Koh, Shizuka

    2015-01-01

    Diquafosol is a drug used for dry eye treatment with a novel mechanism of action. It stimulates the secretion of tear fluid and mucin on the ocular surface, thus enabling us to selectively treat the tear film layer, playing an important role in the establishment of the concept of "Tear Film Oriented Therapy (TFOT)", an effective therapeutic approach to dry eye in Japan. The 3% diquafosol ophthalmic solution has been widely used for the treatment of dry eye in clinical practice, and it is currently available in Japan and South Korea. This review provides an overview of the clinical utility of 3% diquafosol ophthalmic solution, focusing on the results of clinical studies on various types of dry eye, including aqueous-deficient dry eye, short tear film breakup time-type dry eye, and post dry eye after laser in situ keratomileusis. It also introduces the additive effect of diquafosol on sodium hyaluronate monotherapy for dry eye, and the effect of 3% diquafosol ophthalmic solution for dry eye-related conditions. Additionally, it summarizes the ocular effects of diquafosol in healthy human eyes. Lastly, the importance of improving tear film stability in dry eye treatment, as well as general advances in dry eye treatments, are described.

  10. Effect of repair of radial tears at the root of the posterior horn of the medial meniscus with the pullout suture technique: a biomechanical study using porcine knees.

    PubMed

    Seo, Jeong-Hee; Li, Guoan; Shetty, Gautam M; Kim, Ji-Hoon; Bae, Ji-Hoon; Jo, Myoung-Lae; Kim, Jung-Sung; Lee, Sung-Jae; Nha, Kyung-Wook

    2009-11-01

    Our purpose was to evaluate the result of radial tears at the root of the posterior horn of the medial meniscus (PHMM) in terms of tibiofemoral contact mechanics and the effectiveness of pullout sutures for such tears. Eleven mature pig knees each underwent 15 different testing conditions with an intact, simulated (incised) radial tear at the root of the PHMM and placement of pullout sutures in the radial tears of the medial meniscus at 5 different angles of flexion (0 degrees, 15 degrees, 30 degrees, 60 degrees, and 90 degrees ) under a 1,500-N axial load. A K-Scan pressure sensor (Tekscan, Boston, MA) was used to measure medial tibiofemoral contact area and peak tibiofemoral contact pressure. Data were analyzed to assess the difference in medial contact area and tibiofemoral peak contact pressure among the 3 meniscal conditions at various degrees of knee flexion. The mean contact area was significantly lower, and the peak tibiofemoral contact pressure was significantly high in knees with simulated radial tears at all angles of knee flexion compared with knees with intact menisci (P < .0001). The peak tibiofemoral contact pressure after the pullout suture technique was significantly high at 0 degrees and 15 degrees of flexion (P < .0001) compared with intact knee specimens. Failure of sutures occurred in 45% of the specimens at 0 degrees of flexion. Radial tears at the root of the PHMM in a porcine model significantly increased medial tibiofemoral contact pressure and decreased contact area. Although repair of tears of the PHMM with the pullout suture technique aids in significantly reducing tibiofemoral peak contact pressure between 30 degrees and 90 degrees , it remains significantly high at 0 degrees and 15 degrees of flexion. Pullout sutures for radial tears at the root of the PHMM may lead to an increase in peak medial tibiofemoral contact pressure and may be prone to mechanical failure, especially during the stance (loading) phase of gait (mean, 15 degrees of flexion).

  11. Hand-assisted laparoscopic repair of a grade IV rectal tear in a postparturient mare.

    PubMed

    Stewart, Suzanne G; Johnston, Janet K; Parente, Eric J

    2014-10-01

    An 8-year-old multiparous Thoroughbred broodmare was admitted for evaluation of a rectal tear sustained during parturition. On initial evaluation, the mare had mild signs of abdominal discomfort. A full-thickness rectal tear located 30 cm cranial to the anus and extending approximately 15 cm longitudinally along the surface of the small colon between the 4 and 6 o'clock positions, when viewed from behind, was diagnosed on examination per rectum. Laparoscopic evaluation of the abdomen was performed to assess the tear and extent of peritoneal contamination. A hand-assisted repair via a flank incision was performed. The tear was closed in a single-layer, simple continuous pattern with size-0 polydioxanone with a handheld needle holder. Subsequently, a ventral midline celiotomy was performed, and intestinal contents were evacuated via a pelvic flexure enterotomy and a typhlotomy. Following surgery, the mare was managed with IV fluid therapy, partial parenteral nutrition, antimicrobials, and NSAIDs for 5 to 7 days before being gradually reintroduced to a complete pelleted feed and alfalfa hay. Prior to discharge, examination per rectum revealed no stricture formation associated with repair. The mare was discharged from the hospital and performed successfully as a broodmare, with the delivery of a live foal 1 year after surgery. Successful repair with an excellent outcome was achieved in this mare. Hand-assisted laparoscopic repair should be considered as a possible treatment option in horses with grade IV rectal tears.

  12. [Effect of melatonin instillations on the clinical course of experimental uveitis and biochemical processes in tears and aqueous humor].

    PubMed

    Chesnokova, N B; Beznos, O V; Lozinskaya, N A; Beyshenova, G A; Nesterova, T V

    2016-01-01

    Acute immunogenic uveitis was modeled in rabbits via the subcutaneous and intravitreal injections of normal horse serum. We studied the effect of instillations of 0.1% melatonin solution on the clinical course of uveitis and biochemical parameters of tear fluid and aqueous humor: antioxi-dant activity, protein concentration and α(2)-macroglobulin level. Melatonin instillations decreased clinical manifestations of uveitis. We found that the antioxidant activity in tears of the rabbits treated with melatonin was substantially higher and the α(2)-macroglobulin level lower than in untreated animals. Antioxidant activity in aqueous humor taken on day 10 of uveitis was also twice higher while protein and α(2)-macroglobulin levels were 1.5-2 times lower than in untreated animals. These data indicate that instillations of melatonin increase the local antioxidant activity and decrease the acuity of inflammation and permeability of hematoophthalmic barrier in uveitis.

  13. Effects of resonant magnetic perturbation on the triggering and the evolution of double-tearing mode

    NASA Astrophysics Data System (ADS)

    Wang, L.; Lin, W. B.; Wang, X. Q.

    2018-02-01

    The effects of resonant magnetic perturbation on the triggering and the evolution of the double-tearing mode are investigated by using nonlinear magnetohydrodynamics simulations in a slab geometry. It is found that the double-tearing mode can be destabilized by boundary magnetic perturbation. Moreover, the mode has three typical development stages before it reaches saturation: the linear stable stage, the linear-growth stage, and the exponential-growth stage. The onset and growth of the double-tearing mode significantly depend on the boundary magnetic perturbations, particularly in the early development stage of the mode. The influences of the magnetic perturbation amplitude on the mode for different separations of the two rational surfaces are also discussed.

  14. Non-axisymmetric Flows and Transport in the Edge of MST

    NASA Astrophysics Data System (ADS)

    Miller, Matthew Charles

    Magnetic reconnection occurs in plasmas all throughout the universe and is responsible for spectacular and perplexing phenomena. In the Madison Symmetric Torus (MST) reversed field pinch (RFP), reconnection occurs as quasi-periodic bursts of tearing instabilities (saw-teeth), which give rise to a number of processes that affect the RFP's global behavior and confinement. This work examines the structure of turbulent plasma flow in the edge region and its role in affecting momentum and particle transport through the use of several insertable probes and novel ensemble techniques. Very few measurements exist of tearing mode flow structures. The flow structure has now been measured for m = 0 modes and is in good agreement with theoretical expectations for nonlinear resistive MHD calculated for the RFP using DEBS and NIMROD. The flows are predicted and measured to be different than the classical Sweet-Parker picture with symmetric inward flows. The flow fluctuations have a profound effect on momentum transport, which is trans- ported rapidly at the crash. This work advances the understanding of this process by measuring the Reynolds stress associated with turbulent flow. Combined with measurements of the Maxwell stress, a new picture for magnetic self-organization in the RFP via two-fluid physics has emerged. The Reynolds and Maxwell stresses are measured to be an order of magnitude larger than the rate of change in inertia but oppositely directed such that they almost cancel. Two-fluid effects are significant because of the relationship be- tween the Maxwell stress and the Hall dynamo, a term only existing in two-fluid theories. This relationship inextricably couples the momentum dynamics with the current dynamics. Indeed, the parallel momentum profile exhibits a relaxation at the crash akin to the relaxation seen in the parallel current density profile. Tearing modes also drive particle transport. Fluctuation-induced particle flux is resolved through a crash by measuring it directly as < neur>. The flux increases dramatically during a crash and is non-axisymmetric. Between crashes, the transport from tearing is small, which agrees with previous measurements that identified electrostatic transport as dominant at that time.

  15. Effect of extraoral aging conditions on mechanical properties of maxillofacial silicone elastomer.

    PubMed

    Hatamleh, Muhanad M; Polyzois, Gregory L; Silikas, Nick; Watts, David C

    2011-08-01

    The purpose of this study was to investigate the effect of extraoral human and environmental conditions on the mechanical properties (tensile strength and modulus, elongation, tear strength hardness) of maxillofacial silicone elastomer. Specimens were fabricated using TechSil-S25 silicone elastomer (Technovent Ltd, Leeds, UK). Eight groups were prepared (21 specimens in each group; eight tensile, eight tear, five hardness) and conditioned differently as follows (groups 1 through 8): Dry storage for 24 hours; dry storage in dark for 6 months; storage in simulated sebum solution for 6 months; storage in simulated acidic perspiration for 6 months; accelerated artificial daylight aging under controlled moisture for 360 hours; outdoor weathering for 6 months; storage in antimicrobial silicone-cleaning solution for 30 hours; and mixed conditioning of sebum storage and light aging for 360 hours. The conditioning period selected simulated a prosthesis being in service for up to 12 months. Tensile and tear test specimens were fabricated and tested according to the International Standards Organization (ISO) standards no. 37 and 34, respectively. Shore A hardness test specimens were fabricated and tested according to the American Standards for Testing and Materials (ASTM) D 2240. Data were analyzed with one-way ANOVA, Bonferroni, and Dunnett's T3 post hoc tests (p < 0.05). Weibull analysis was also used for tensile strength and tear strength. Statistically significant differences were evident among all properties tested. Mixed conditioning of simulated sebum storage under accelerated artificial daylight aging significantly degraded mechanical properties of the silicone (p < 0.05). Mechanical properties of maxillofacial elastomers are adversely affected by human and environmental factors. Mixed aging of storage in simulated sebum under accelerated daylight aging was the most degrading regime. Accelerated aging of silicone specimens in simulated sebum under artificial daylight for 12 months of simulated clinical service greatly affected functional properties of silicone elastomer; however, in real practice, the effect is modest, since sebum concentration is lower, and daylight is less concentrated. © 2011 by The American College of Prosthodontists.

  16. Why Does the Healthy Cornea Resist Pseudomonas aeruginosa Infection?

    PubMed Central

    Evans, David J.; Fleiszig, Suzanne M. J.

    2013-01-01

    Purpose To provide our perspective on why the cornea is resistant to infection based on our research results with Pseudomonas aeruginosa. Perspective We focus on our current understanding of the interplay between bacteria, tear fluid and the corneal epithelium that determine health as the usual outcome, and propose a theoretical model for how contact lens wear might change those interactions to enable susceptibility to P. aeruginosa infection. Methods Use of “null-infection” in vivo models, cultured human corneal epithelial cells, contact lens-wearing animal models, and bacterial genetics help to elucidate mechanisms by which P. aeruginosa survive at the ocular surface, adheres, and traverses multilayered corneal epithelia. These models also help elucidate the molecular mechanisms of corneal epithelial innate defense. Results and Discussion Tear fluid and the corneal epithelium combine to make a formidable defense against P. aeruginosa infection of the cornea. Part of that defense involves the expression of antimicrobials such as β-defensins, the cathelicidin LL-37, cytokeratin-derived antimicrobial peptides, and RNase7. Immunomodulators such as SP-D and ST2 also contribute. Innate defenses of the cornea depend in part on MyD88, a key adaptor protein of TLR and IL-1R signaling, but the basal lamina represents the final barrier to bacterial penetration. Overcoming these defenses involves P. aeruginosa adaptation, expression of the type three secretion system, proteases, and P. aeruginosa biofilm formation on contact lenses. Conclusion After more than two decades of research focused on understanding how contact lens wear predisposes to P. aeruginosa infection, our working hypothesis places blame for microbial keratitis on bacterial adaptation to ocular surface defenses, combined with changes to the biochemistry of the corneal surface caused by trapping bacteria and tear fluid against the cornea under the lens. PMID:23601656

  17. Simulation of Thin Film Equations on an Eye-Shaped Domain with Moving Boundary

    NASA Astrophysics Data System (ADS)

    Brosch, Joseph; Driscoll, Tobin; Braun, Richard

    During a normal eye blink, the upper lid moves, and during the upstroke the lid paints a thin tear film over the exposed corneal and conjunctival surfaces. This thin tear film may be modeled by a nonlinear fourth-order PDE derived from lubrication theory. A major stumbling block in the numerical simulation of this model is to include both the geometry of the eye and the movement of the eyelid. Using a pair of orthogonal and conformal maps, we transform a computational box into a rough representation of a human eye where we proceed to simulate the thin tear film equations. Although we give up some realism, we gain spectrally accurate numerical methods on the computational box. We have applied this method to the heat equation on the blinking domain with both Dirichlet and no-flux boundary conditions, in each case demonstrating at least 10 digits of accuracy.. We are able to perform these simulations very quickly (generally in under a minute) using a desktop version of MATLAB. This project was supported by Grant 1022706 (R.J.B., T.A.D., J.K.B.) from the NSF.

  18. Accuracy of two osmometers on standard samples: electrical impedance technique and freezing point depression technique

    NASA Astrophysics Data System (ADS)

    García-Resúa, Carlos; Pena-Verdeal, Hugo; Miñones, Mercedes; Gilino, Jorge; Giraldez, Maria J.; Yebra-Pimentel, Eva

    2013-11-01

    High tear fluid osmolarity is a feature common to all types of dry eye. This study was designed to establish the accuracy of two osmometers, a freezing point depression osmometer (Fiske 110) and an electrical impedance osmometer (TearLab™) by using standard samples. To assess the accuracy of the measurements provided by the two instruments we used 5 solutions of known osmolarity/osmolality; 50, 290 and 850 mOsm/kg and 292 and 338 mOsm/L. Fiske 110 is designed to be used in samples of 20 μl, so measurements were made on 1:9, 1:4, 1:1 and 1:0 dilutions of the standards. Tear Lab is addressed to be used in tear film and only a sample of 0.05 μl is required, so no dilutions were employed. Due to the smaller measurement range of the TearLab, the 50 and 850 mOsm/kg standards were not included. 20 measurements per standard sample were used and differences with the reference value was analysed by one sample t-test. Fiske 110 showed that osmolarity measurements differed statistically from standard values except those recorded for 290 mOsm/kg standard diluted 1:1 (p = 0.309), the 292 mOsm/L H2O sample (1:1) and 338 mOsm/L H2O standard (1:4). The more diluted the sample, the higher the error rate. For the TearLab measurements, one-sample t-test indicated that all determinations differed from the theoretical values (p = 0.001), though differences were always small. For undiluted solutions, Fiske 110 shows similar performance than TearLab. However, for the diluted standards, Fiske 110 worsens.

  19. Rapamycin Eye Drops Suppress Lacrimal Gland Inflammation In a Murine Model of Sjögren's Syndrome

    PubMed Central

    Shah, Mihir; Edman, Maria C.; Reddy Janga, Srikanth; Yarber, Frances; Meng, Zhen; Klinngam, Wannita; Bushman, Jonathan; Ma, Tao; Liu, Siyu; Louie, Stan; Mehta, Arjun; Ding, Chuanqing; MacKay, J. Andrew; Hamm-Alvarez, Sarah F.

    2017-01-01

    Purpose To evaluate the efficacy of topical rapamycin in treating autoimmune dacryoadenitis in a mouse model of Sjögren's syndrome. Methods We developed rapamycin in a poly(ethylene glycol)-distearoyl phosphatidylethanolamine (PEG-DSPE) micelle formulation to maintain solubility. Rapamycin or PEG-DSPE eye drops (vehicle) were administered in a well-established Sjögren's syndrome disease model, the male nonobese diabetic (NOD) mice, twice daily for 12 weeks starting at 8 weeks of age. Mouse tear fluid was collected and tear Cathepsin S, a putative tear biomarker for Sjögren's syndrome, was measured. Lacrimal glands were retrieved for histological evaluation, and quantitative real-time PCR of genes associated with Sjögren's syndrome pathogenesis. Tear secretion was measured using phenol red threads, and corneal fluorescein staining was used to assess corneal integrity. Results Lymphocytic infiltration of lacrimal glands from rapamycin-treated mice was significantly (P = 0.0001) reduced by 3.8-fold relative to vehicle-treated mice after 12 weeks of treatment. Rapamycin, but not vehicle, treatment increased tear secretion and decreased corneal fluorescein staining after 12 weeks. In rapamycin-treated mice, Cathepsin S activity was significantly reduced by 3.75-fold in tears (P < 0.0001) and 1.68-fold in lacrimal gland lysates (P = 0.003) relative to vehicle-treated mice. Rapamycin significantly altered the expression of several genes linked to Sjögren's syndrome pathogenesis, including major histocompatibility complex II, TNF-α, IFN-γ, and IL-12a, as well as Akt3, an effector of autophagy. Conclusions Our findings suggest that topical rapamycin reduces autoimmune-mediated lacrimal gland inflammation while improving ocular surface integrity and tear secretion, and thus has potential for treating Sjögren's syndrome–associated dry eye. PMID:28122086

  20. [Evaluation of chemokines in tears of patients with infectious keratitis].

    PubMed

    Hori, Shinsuke; Shoji, Jun; Inada, Noriko; Sawa, Mitsuru

    2013-02-01

    To investigate the chemokine profile in tears of patients with infectious keratitis. Subjects were 32 eyes of 16 patients with infectious keratitis and 5 eyes of 5 healthy volunteers as a control. The patients with infectious keratitis were classified into two groups of eyes: 10 with bacterial keratitis and 6 with Acanthamoeba keratitis. Tear fluid was obtained from both eyes of the patients with infectious keratitis and from the right eyes of the control subjects using filter paper. Chemokine concentration (unit: Odu/mm2) and its profile in tears was analyzed using an antibody-array. In terms of chemokine profile in the bacterial keratitis group, the expression volume of interleukin-8 (IL-8) and monocyte chemoattractant protein-1 (MCP-1) in the diseased eyes was significantly higher than in the healthy eyes (p < 0.05). The expression volume of mucosae-associated epithelial chemokines (MECs) in the diseased eyes of the bacterial keratitis group was significantly lower than in the healthy eyes of that group (p < 0.05). In the Acanthamoeba keratitis group, chemokines were not significantly increased in the diseased eyes compared with those in the healthy eyes. However, MCP-1 was increased in tears of the Acanthamoeba keratitis group. Regarding the chemokine ratio, the IL-8/MEC ratio in the diseased eyes of the Pseudomonas keratitis group and the MCP-1/IL-8 in the diseased eyes of the Acanthamoeba keratitis group showed a significantly high level (p < 0.05). We concluded that the analyses of the chemokine profile and chemokine ratio in the tears of infectious keratitis patients is useful as a clinical tear laboratory test to interpret the pathologic condition of infectious keratitis

  1. Tear film proteome in age-related macular degeneration.

    PubMed

    Winiarczyk, Mateusz; Kaarniranta, Kai; Winiarczyk, Stanisław; Adaszek, Łukasz; Winiarczyk, Dagmara; Mackiewicz, Jerzy

    2018-06-01

    Age-related macular degeneration (AMD) is the main reason for blindness in elderly people in the developed countries. Current screening protocols have limitations in detecting the early signs of retinal degeneration. Therefore, it would be desirable to find novel biomarkers for early detection of AMD. Development of novel biomarkers would help in the prevention, diagnostics, and treatment of AMD. Proteomic analysis of tear film has shown promise in this research area. If an optimal set of biomarkers could be obtained from accessible body fluids, it would represent a reliable way to monitor disease progression and response to novel therapies. Tear films were collected on Schirmer strips from a total of 22 patients (8 with wet AMD, 6 with dry AMD, and 8 control individuals). 2D electrophoresis was used to separate tear film proteins prior to their identification with matrix-assisted laser desorption/ionization time of flight spectrometer (MALDI-TOF/TOF) and matching with functional databases. A total of 342 proteins were identified. Most of them were previously described in various proteomic studies concerning AMD. Shootin-1, histatin-3, fidgetin-like protein 1, SRC kinase signaling inhibitor, Graves disease carrier protein, actin cytoplasmic 1, prolactin-inducible protein 1, and protein S100-A7A were upregulated in the tear film samples isolated from AMD patients and were not previously linked with this disease in any proteomic analysis. The upregulated proteins supplement our current knowledge of AMD pathogenesis, providing evidence that certain specific proteins are expressed into the tear film in AMD. As far we are aware, this is the first study to have undertaken a comprehensive in-depth analysis of the human tear film proteome in AMD patients.

  2. Tear fluid proteomics multimarkers for diabetic retinopathy screening

    PubMed Central

    2013-01-01

    Background The aim of the project was to develop a novel method for diabetic retinopathy screening based on the examination of tear fluid biomarker changes. In order to evaluate the usability of protein biomarkers for pre-screening purposes several different approaches were used, including machine learning algorithms. Methods All persons involved in the study had diabetes. Diabetic retinopathy (DR) was diagnosed by capturing 7-field fundus images, evaluated by two independent ophthalmologists. 165 eyes were examined (from 119 patients), 55 were diagnosed healthy and 110 images showed signs of DR. Tear samples were taken from all eyes and state-of-the-art nano-HPLC coupled ESI-MS/MS mass spectrometry protein identification was performed on all samples. Applicability of protein biomarkers was evaluated by six different optimally parameterized machine learning algorithms: Support Vector Machine, Recursive Partitioning, Random Forest, Naive Bayes, Logistic Regression, K-Nearest Neighbor. Results Out of the six investigated machine learning algorithms the result of Recursive Partitioning proved to be the most accurate. The performance of the system realizing the above algorithm reached 74% sensitivity and 48% specificity. Conclusions Protein biomarkers selected and classified with machine learning algorithms alone are at present not recommended for screening purposes because of low specificity and sensitivity values. This tool can be potentially used to improve the results of image processing methods as a complementary tool in automatic or semiautomatic systems. PMID:23919537

  3. Stabilizing effect of helical current drive on tearing modes

    NASA Astrophysics Data System (ADS)

    Yuan, Y.; Lu, X. Q.; Dong, J. Q.; Gong, X. Y.; Zhang, R. B.

    2018-01-01

    The effect of helical driven current on the m = 2/n = 1 tearing mode is studied numerically in a cylindrical geometry using the method of reduced magneto-hydro-dynamic simulation. The results show that the local persistent helical current drive from the beginning time can be applied to control the tearing modes, and will cause a rebound effect called flip instability when the driven current reaches a certain value. The current intensity threshold value for the occurrence of flip instability is about 0.00087I0. The method of controlling the development of tearing mode with comparative economy is given. If the local helical driven current is discontinuous, the magnetic island can be controlled within a certain range, and then, the tearing modes stop growing; thus, the flip instability can be avoided. We also find that the flip instability will become impatient with delay injection of the driven current because the high order harmonics have been developed in the original O-point. The tearing mode instability can be controlled by using the electron cyclotron current drive to reduce the gradient of the current intensity on the rational surfaces.

  4. Formation of Hot Tear Under Controlled Solidification Conditions

    NASA Astrophysics Data System (ADS)

    Subroto, Tungky; Miroux, Alexis; Bouffier, Lionel; Josserond, Charles; Salvo, Luc; Suéry, Michel; Eskin, Dmitry G.; Katgerman, Laurens

    2014-06-01

    Aluminum alloy 7050 is known for its superior mechanical properties, and thus finds its application in aerospace industry. Vertical direct-chill (DC) casting process is typically employed for producing such an alloy. Despite its advantages, AA7050 is considered as a "hard-to-cast" alloy because of its propensity to cold cracking. This type of cracks occurs catastrophically and is difficult to predict. Previous research suggested that such a crack could be initiated by undeveloped hot tears (microscopic hot tear) formed during the DC casting process if they reach a certain critical size. However, validation of such a hypothesis has not been done yet. Therefore, a method to produce a hot tear with a controlled size is needed as part of the verification studies. In the current study, we demonstrate a method that has a potential to control the size of the created hot tear in a small-scale solidification process. We found that by changing two variables, cooling rate and displacement compensation rate, the size of the hot tear during solidification can be modified in a controlled way. An X-ray microtomography characterization technique is utilized to quantify the created hot tear. We suggest that feeding and strain rate during DC casting are more important compared with the exerted force on the sample for the formation of a hot tear. In addition, we show that there are four different domains of hot-tear development in the explored experimental window—compression, microscopic hot tear, macroscopic hot tear, and failure. The samples produced in the current study will be used for subsequent experiments that simulate cold-cracking conditions to confirm the earlier proposed model.

  5. Determination of water-soluble and fat-soluble vitamins in tears and blood serum of infants and parents by liquid chromatography/mass spectrometry.

    PubMed

    Khaksari, Maryam; Mazzoleni, Lynn R; Ruan, Chunhai; Kennedy, Robert T; Minerick, Adrienne R

    2017-02-01

    Tears serve as a viable diagnostic fluid with advantages including less invasive sample to collect and less complex to prepare for analysis. Several water-soluble and fat-soluble vitamins were detected and quantified in human tears and compared with blood serum levels. Samples from 15 family pairs, each pair consisting of a four-month-old infant and one parent were analyzed; vitamin concentrations were compared between tears and blood serum for individual subjects, between infants and parents, and against self-reported dietary intakes. Water-soluble vitamins B 1 , B 2 , B 3 (nicotinamide), B 5 , B 9 and fat-soluble vitamin E (α-tocopherol) were routinely detected in tears and blood serum while fat-soluble vitamin A (retinol) was detected only in blood serum. Water-soluble vitamin concentrations measured in tears and blood serum of single subjects were comparable, while higher concentrations were measured in infants compared to their parents. Fat-soluble vitamin E concentrations were lower in tears than blood serum with no significant difference between infants and parents. Serum vitamin A concentrations were higher in parents than infants. Population trends were compiled and quantified using a cross correlation factor. Strong positive correlations were found between tear and blood serum concentrations of vitamin E from infants and parents and vitamin B 3 concentrations from parents, while slight positive correlations were detected for infants B 3 and parents B 1 and B 2 concentrations. Correlations between infants and parents were found for the concentrations of B 1 , B 2 , B 3 , and E in tears, and the concentrations of B 2, A, and E in blood serum. Stronger vitamin concentration correlations were found between infants and parents for the breast-fed infants, while no significant difference was observed between breast-fed and bottle-fed infants. This work is the first to demonstrate simultaneous vitamin A, B, and E detection and to quantify correlations between vitamin concentrations in tears and blood serum. Our results suggest that tears are a viable biofluid to monitor nutritional health because they sufficiently mirror blood serum data and may enhance the speed of deficiency diagnoses. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. In vivo tear film thickness measurement and tear film dynamics visualization using spectral domain OCT and an efficient delay estimator

    NASA Astrophysics Data System (ADS)

    Aranha dos Santos, Valentin; Schmetterer, Leopold; Gröschl, Martin; Garhofer, Gerhard; Werkmeister, René M.

    2016-03-01

    Dry eye syndrome is a highly prevalent disease of the ocular surface characterized by an instability of the tear film. Traditional methods used for the evaluation of tear film stability are invasive or show limited repeatability. Here we propose a new noninvasive approach to measure tear film thickness using an efficient delay estimator and ultrahigh resolution spectral domain OCT. Silicon wafer phantoms with layers of known thickness and group index were used to validate the estimator-based thickness measurement. A theoretical analysis of the fundamental limit of the precision of the estimator is presented and the analytical expression of the Cramér-Rao lower bound (CRLB), which is the minimum variance that may be achieved by any unbiased estimator, is derived. The performance of the estimator against noise was investigated using simulations. We found that the proposed estimator reaches the CRLB associated with the OCT amplitude signal. The technique was applied in vivo in healthy subjects and dry eye patients. Series of tear film thickness maps were generated, allowing for the visualization of tear film dynamics. Our results show that the central tear film thickness precisely measured in vivo with a coefficient of variation of about 0.65% and that repeatable tear film dynamics can be observed. The presented method has the potential of being an alternative to breakup time measurements (BUT) and could be used in clinical setting to study patients with dry eye disease and monitor their treatments.

  7. Neurturin-deficient mice develop dry eye and keratoconjunctivitis sicca.

    PubMed

    Song, Xiu Jun; Li, De-Quan; Farley, William; Luo, Li Hui; Heuckeroth, Robert O; Milbrandt, Jeffrey; Pflugfelder, Stephen C

    2003-10-01

    Neurturin has been identified as a neurotrophic factor for parasympathetic neurons. Neurturin-deficient (NRTN(-/-)) mice have defective parasympathetic innervation of their lacrimal glands. This study was conducted to evaluate tear function and ocular surface phenotype in NRTN(-/-) mice. Determined by tail genomic DNA PCR, 25 NRTN(-/-) mice and 17 neurturin-normal (NRTN(+/+)) mice aged 6 weeks to 4 months were evaluated. Aqueous tear production, tear fluorescein clearance and corneal sensation were serially measured. Corneal permeability to AlexaFluor dextran (AFD; Molecular Probes, Eugene, OR) was measured by a fluorometric assay at 485 nm excitation and 530 nm emission. Histology was evaluated in PAS-stained sections. Mucin and HLA class II (IA) antigen were assessed by immunofluorescent staining. Tear IL-1beta was measured by ELISA, and tear matrix metalloproteinase (MMP)-9 by zymography. Gene expression in the corneal epithelia was analyzed by semiquantitative RT-PCR. In comparison to that in age-matched NRTN(+/+) mice, aqueous tear production, tear fluorescein clearance, and corneal sensation were significantly reduced in NRTN(-/-) mice, whereas corneal permeability to AFD was significantly increased. Immunoreactive MUC-4 and -5AC mucin and goblet cell density (P < 0.001) in the conjunctiva of NRTN(-/-) mice were lower than in NRTN(+/+) mice. The expression of MUC-1 and -4 mRNA by the corneal epithelium was reduced in NRTN(-/-) mice. There were a significantly greater number of IA antigen-positive conjunctival epithelial cells in NRTN(-/-) mice than NRTN(+/+) mice. Tear fluid IL-1beta and MMP-9 concentrations and the expression of IL-1beta, TNF-alpha, macrophage inflammatory protein (MIP)-2, cytokine-induced neutrophil chemoattractant (KC), and MMP-9 mRNA by the corneal epithelia were significantly increased in NRTN(-/-) mice, compared with NRTN(+/+) mice. Neurturin-deficient mice show phenotypic changes and ocular surface inflammation that mimic human keratoconjunctivitis sicca. This model supports the importance of a functional ocular surface-central nervous system-lacrimal gland sensory-autonomic neural network in maintaining ocular surface health and homeostasis.

  8. Scaling and Instabilities in Bubble Pinch-Off

    NASA Astrophysics Data System (ADS)

    Burton, J. C.; Waldrep, R.; Taborek, P.

    2005-05-01

    We have used a 100 000 frame-per-second video to analyze the pinch-off of nitrogen gas bubbles in fluids with a wide range of viscosity. If the external fluid is highly viscous (ηext>100 cP), the bubble neck radius is proportional to the time before break, τ, and decreases smoothly to zero. If the external fluid has low viscosity (ηext<10 cP), the radius scales as τ1/2 until an instability develops in the gas bubble, which causes the neck to rupture and tear apart. Finally, if the viscosity of the external fluid is in an intermediate range, an elongated thread is formed, which breaks apart into micron-sized bubbles.

  9. Sys-BodyFluid: a systematical database for human body fluid proteome research

    PubMed Central

    Li, Su-Jun; Peng, Mao; Li, Hong; Liu, Bo-Shu; Wang, Chuan; Wu, Jia-Rui; Li, Yi-Xue; Zeng, Rong

    2009-01-01

    Recently, body fluids have widely become an important target for proteomic research and proteomic study has produced more and more body fluid related protein data. A database is needed to collect and analyze these proteome data. Thus, we developed this web-based body fluid proteome database Sys-BodyFluid. It contains eleven kinds of body fluid proteomes, including plasma/serum, urine, cerebrospinal fluid, saliva, bronchoalveolar lavage fluid, synovial fluid, nipple aspirate fluid, tear fluid, seminal fluid, human milk and amniotic fluid. Over 10 000 proteins are presented in the Sys-BodyFluid. Sys-BodyFluid provides the detailed protein annotations, including protein description, Gene Ontology, domain information, protein sequence and involved pathways. These proteome data can be retrieved by using protein name, protein accession number and sequence similarity. In addition, users can query between these different body fluids to get the different proteins identification information. Sys-BodyFluid database can facilitate the body fluid proteomics and disease proteomics research as a reference database. It is available at http://www.biosino.org/bodyfluid/. PMID:18978022

  10. Sys-BodyFluid: a systematical database for human body fluid proteome research.

    PubMed

    Li, Su-Jun; Peng, Mao; Li, Hong; Liu, Bo-Shu; Wang, Chuan; Wu, Jia-Rui; Li, Yi-Xue; Zeng, Rong

    2009-01-01

    Recently, body fluids have widely become an important target for proteomic research and proteomic study has produced more and more body fluid related protein data. A database is needed to collect and analyze these proteome data. Thus, we developed this web-based body fluid proteome database Sys-BodyFluid. It contains eleven kinds of body fluid proteomes, including plasma/serum, urine, cerebrospinal fluid, saliva, bronchoalveolar lavage fluid, synovial fluid, nipple aspirate fluid, tear fluid, seminal fluid, human milk and amniotic fluid. Over 10,000 proteins are presented in the Sys-BodyFluid. Sys-BodyFluid provides the detailed protein annotations, including protein description, Gene Ontology, domain information, protein sequence and involved pathways. These proteome data can be retrieved by using protein name, protein accession number and sequence similarity. In addition, users can query between these different body fluids to get the different proteins identification information. Sys-BodyFluid database can facilitate the body fluid proteomics and disease proteomics research as a reference database. It is available at http://www.biosino.org/bodyfluid/.

  11. Incompressibility without tears - How to avoid restrictions of mixed formulation

    NASA Technical Reports Server (NTRS)

    Zienkiewicz, O. C.; Wu, J.

    1991-01-01

    Several time-stepping schemes for incompressibility problems are presented which can be solved directly for steady state or iteratively through the time domain. The difficulty of mixed interpolation is avoided by using these schemes. The schemes are applicable to problems of fluid and solid mechanics.

  12. Noninvasive diagnostic devices for diabetes through measuring tear glucose.

    PubMed

    Zhang, Jin; Hodge, William; Hutnick, Cindy; Wang, Xianbin

    2011-01-01

    This article reviews the development of a noninvasive diagnostic for diabetes by detecting ocular glucose. Early diagnosis and daily management are very important to diabetes patients to ensure a healthy life. Commercial blood glucose sensors have been used since the 1970s. Millions of diabetes patients have to prick their finger for a drop of blood 4-5 times a day to check blood glucose levels--almost 1800 times annually. There is a strong need to have a noninvasive device to help patients to manage the disease easily and painlessly. Instead of detecting the glucose in blood, monitoring the glucose level in other body fluids may provide a feasible approach for noninvasive diagnosis and diabetes control. Tear glucose has been studied for several decades. This article reviews studies on ocular glucose and its monitoring methods. Attempts to continuously monitor the concentration of tear glucose by using contact lens-based sensors are discussed as well as our current development of a nanostructured lens-based sensor for diabetes. This disposable biosensor for the detection of tear glucose may provide an alternative method to help patients manage the disease conveniently. © 2010 Diabetes Technology Society.

  13. Location of eastern Mediterranean hot springs induced by mantle heat flow due to slab roll-back and tearing

    NASA Astrophysics Data System (ADS)

    Roche, V. M.; Sternai, P.; Guillou-Frottier, L.; Jolivet, L.; Gerya, T.

    2016-12-01

    The Aegean-Anatolian retreating subduction and collision zones have been investigated through 3D numerical geodynamic models involving slab rollback/tearing/breakoff constrained by, for instance, seismic tomography or anisotropy and geochemical proxies. Here we integrate these investigations by using geothermal anomaly measurements from western Turkey. Such data provides insights into the thermal state of the Aegean-Anatolian region at depth and reflects the development of a widespread active geothermal province that is unlikely to be related only to the Quaternary volcanism because this has a too limited extent in space and time. Firstly, we look for possible connections with larger-scale mantle dynamics and use 3D high-resolution petrological and thermo-mechanical numerical models to quantify the potential contribution of the Aegean-Anatolian subduction dynamics to such measured thermal anomalies. Secondly, the subduction-induced thermal signature at the base of the continental crust is then inserted as the imposed basal thermal condition of 2D models dedicated to the understanding of fluid flow in the shallow crust. These models couple heat transfer and fluid flow equations with appropriate fluid and rock physical properties. Results from the 3D numerical models suggest an efficient control of subduction-related asthenospheric return flow on the regional distribution of thermal anomalies. Results from the 2D numerical models also highlight that low angle normal faults (detachments) in the back-arc region can control the bulk of the heat transport and fluid circulation patterns. Such detachments can drain hot crustal and/or mantellic fluids down to several kilometers depths, thus allowing for or fostering deep fluid circulation.

  14. Gallium arsenide based surface plasmon resonance for glucose monitoring

    NASA Astrophysics Data System (ADS)

    Patil, Harshada; Sane, Vani; Sriram, G.; Indumathi, T. S; Sharan, Preeta

    2015-07-01

    The recent trends in the semiconductor and microwave industries has enabled the development of scalable microfabrication technology which produces a superior set of performance as against its counterparts. Surface Plasmon Resonance (SPR) based biosensors are a special class of optical sensors that become affected by electromagnetic waves. It is found that bio-molecular recognition element immobilized on the SPR sensor surface layer reveals a characteristic interaction with various sample solutions during the passage of light. The present work revolves around developing painless glucose monitoring systems using fluids containing glucose like saliva, urine, sweat or tears instead of blood samples. Non-invasive glucose monitoring has long been simulated using label free detection mechanisms and the same concept is adapted. In label-free detection, target molecules are not labeled or altered, and are detected in their natural forms. Label-free detection mechanisms involves the measurement of refractive index (RI) change induced by molecular interactions. These interactions relates the sample concentration or surface density, instead of total sample mass. After simulation it has been observed that the result obtained is highly accurate and sensitive. The structure used here is SPR sensor based on channel waveguide. The tools used for simulation are RSOFT FULLWAVE, MEEP and MATLAB etc.

  15. Behavior of sphingomyelin and ceramide in a tear film lipid layer model.

    PubMed

    Olżyńska, Agnieszka; Cwiklik, Lukasz

    2017-03-01

    Tear film lipid layer is a complex lipid mixture forming the outermost interface between eye and environment. Its key characteristics, such as surface tension and structural stability, are governed by the presence of polar lipids. The origin of these lipids and exact composition of the mixture are still elusive. We focus on two minor polar lipid components of the tear film lipid later: sphingomyelin and ceramide. By employing coarse grain molecular dynamics in silico simulations accompanied by Langmuir balance experiments we provide molecular-level insight into behavior of these two lipids in a tear film lipid layer model. Sphingomyelin headgroups are significantly exposed at the water-lipids boundary while ceramide molecules are incorporated between other lipids frequently interacting with nonpolar lipids. Even though these two lipids increase surface tension of the film, their molecular-level behavior suggests that they have a stabilizing effect on the tear film lipid layer. Copyright © 2016 Elsevier GmbH. All rights reserved.

  16. Simultaneous measurement of lipid and aqueous layers of tear film using optical coherence tomography and statistical decision theory

    NASA Astrophysics Data System (ADS)

    Huang, Jinxin; Clarkson, Eric; Kupinski, Matthew; Rolland, Jannick P.

    2014-03-01

    The prevalence of Dry Eye Disease (DED) in the USA is approximately 40 million in aging adults with about $3.8 billion economic burden. However, a comprehensive understanding of tear film dynamics, which is the prerequisite to advance the management of DED, is yet to be realized. To extend our understanding of tear film dynamics, we investigate the simultaneous estimation of the lipid and aqueous layers thicknesses with the combination of optical coherence tomography (OCT) and statistical decision theory. In specific, we develop a mathematical model for Fourier-domain OCT where we take into account the different statistical processes associated with the imaging chain. We formulate the first-order and second-order statistical quantities of the output of the OCT system, which can generate some simulated OCT spectra. A tear film model, which includes a lipid and aqueous layer on top of a rough corneal surface, is the object being imaged. Then we further implement a Maximum-likelihood (ML) estimator to interpret the simulated OCT data to estimate the thicknesses of both layers of the tear film. Results show that an axial resolution of 1 μm allows estimates down to nanometers scale. We use the root mean square error of the estimates as a metric to evaluate the system parameters, such as the tradeoff between the imaging speed and the precision of estimation. This framework further provides the theoretical basics to optimize the imaging setup for a specific thickness estimation task.

  17. Nonlinear dynamics of toroidal Alfvén eigenmodes in the presence of tearing modes

    NASA Astrophysics Data System (ADS)

    Zhu, J.; Ma, Z. W.; Wang, S.; Zhang, W.

    2018-04-01

    A hybrid simulation is carried out to study nonlinear dynamics of n  =  1 toroidal Alfvén eigenmodes (TAEs) with the m/n  =  2/1 tearing mode. It is found that the n  =  1 TAE is first excited by isotropic energetic particles at the linear stage and reaches the first steady state due to wave-particle interaction. After the saturation of the n  =  1 TAE, the m/n  =  2/1 tearing mode grows continuously and reaches its steady state due to nonlinear mode-mode coupling, especially, the n  =  0 component plays a very important role in the tearing mode saturation. The results suggest that the enhancement of the tearing mode activity with increase of the resistivity could weaken the TAE frequency chirping through the interaction between the p  =  1 TAE resonance and the p  =  2 tearing mode resonance for passing particles in the phase space, which is opposite to the classical physical picture of the TAE frequency chirping that is enhanced with dissipation increase.

  18. Property development for biaxial drawing of ethylene-tetrafluoroehtylene copolymer films and resultant fractural behavior analyzed by in situ X-ray measurements.

    PubMed

    Uehara, Hiroki; Ono, Yasunori; Kakiage, Masaki; Sakamura, Takumi; Masunaga, Hiroyasu; Yukawa, Yasumasa; Higuchi, Yoshiaki; Kamiya, Hiroki; Yamanobe, Takeshi

    2015-03-19

    The property development of the ethylene-tetrafluoroethylene copolymer (ETFE) membrane induced by simultaneous biaxial drawing was investigated. Commonly, tensile strength can be increased by drawing; conversely, tear resistance decreases. In this study, the balance between tensile strength and tear resistance for the resultant ETFE membrane was optimized achieved by a combination of lamination of low molecular weight (LMW) and high molecular weight (HMW) layers and subsequent biaxial drawing. The structural factor determining tear resistance of these biaxially drawn membranes was determined based on in situ small-angle X-ray scattering (SAXS) measurement during tensile deformation simulating tearing tests. Lozenge shaped scattering, which indicated inclined lamellae, was observed during such tensile deformation of the resultant membranes. Remarkably, this inclined lamellar structure was observed for the pure LMW membrane; however, it also appeared at the interface between LMW and HMW layers within biaxially drawn membranes. For the membrane exhibiting the highest tearing strength, the fraction of such inclined lamella increased up to the critical strain corresponding to the actual sample breaking. These results confirm that the inclined lamellar structure absorbed strain during membrane tearing.

  19. General Pharmacokinetic Model for Topically Administered Ocular Drug Dosage Forms.

    PubMed

    Deng, Feng; Ranta, Veli-Pekka; Kidron, Heidi; Urtti, Arto

    2016-11-01

    In ocular drug development, an early estimate of drug behavior before any in vivo experiments is important. The pharmacokinetics (PK) and bioavailability depend not only on active compound and excipients but also on physicochemical properties of the ocular drug formulation. We propose to utilize PK modelling to predict how drug and formulational properties affect drug bioavailability and pharmacokinetics. A physiologically relevant PK model based on the rabbit eye was built to simulate the effect of formulation and physicochemical properties on PK of pilocarpine solutions and fluorometholone suspensions. The model consists of four compartments: solid and dissolved drug in tear fluid, drug in corneal epithelium and aqueous humor. Parameter values and in vivo PK data in rabbits were taken from published literature. The model predicted the pilocarpine and fluorometholone concentrations in the corneal epithelium and aqueous humor with a reasonable accuracy for many different formulations. The model includes a graphical user interface that enables the user to modify parameters easily and thus simulate various formulations. The model is suitable for the development of ophthalmic formulations and the planning of bioequivalence studies.

  20. Orgasmic dural tear: an unusual delayed presentation of postural headache following lumbar discectomy.

    PubMed

    Dannawi, Zaher; Lennon, Shirley Evelyn; Zaidan, Ammar; Khazim, Rabi

    2014-11-28

    A 28-year-old woman presented with a severe unremitting frontal postural headache associated with photophobia. This started immediately after standing following reaching orgasm during sexual intercourse. Fifty-two days previously, the patient underwent bilateral L4-L5 decompression laminotomies and a left L4-L5 discectomy for excision of a large herniated intervertebral disc. Subarachnoid haemorrhage was excluded with a CT scan. Brain and lumbar MRI showed enhancement of the pachymeninges and a cerebrospinal fluid (CSF) leak into the deep soft tissue planes. Conservative treatment for 5 days failed to alleviate the patient's symptoms. An exploration and repair of a dural tear was performed. Subsequently, the headache subsided but the patient developed a low-grade infection requiring 12 weeks of antibiotics. Six months later the patient was asymptomatic. This is the first case report of a delayed presentation of a dural tear occurring during sexual intercourse following lumbar surgery. 2014 BMJ Publishing Group Ltd.

  1. Wearable physiological systems and technologies for metabolic monitoring.

    PubMed

    Gao, Wei; Brooks, George A; Klonoff, David C

    2018-03-01

    Wearable sensors allow continuous monitoring of metabolites for diabetes, sports medicine, exercise science, and physiology research. These sensors can continuously detect target analytes in skin interstitial fluid (ISF), tears, saliva, and sweat. In this review, we will summarize developments on wearable devices and their potential applications in research, clinical practice, and recreational and sporting activities. Sampling skin ISF can require insertion of a needle into the skin, whereas sweat, tears, and saliva can be sampled by devices worn outside the body. The most widely sampled metabolite from a wearable device is glucose in skin ISF for monitoring diabetes patients. Continuous ISF glucose monitoring allows estimation of the glucose concentration in blood without the pain, inconvenience, and blood waste of fingerstick capillary blood glucose testing. This tool is currently used by diabetes patients to provide information for dosing insulin and determining a diet and exercise plan. Similar technologies for measuring concentrations of other analytes in skin ISF could be used to monitor athletes, emergency responders, warfighters, and others in states of extreme physiological stress. Sweat is a potentially useful substrate for sampling analytes for metabolic monitoring during exercise. Lactate, sodium, potassium, and hydrogen ions can be measured in sweat. Tools for converting the concentrations of these analytes sampled from sweat, tears, and saliva into blood concentrations are being developed. As an understanding of the relationships between the concentrations of analytes in blood and easily sampled body fluid increases, then the benefits of new wearable devices for metabolic monitoring will also increase.

  2. Preparation and clinical evaluation of succinylated collagen punctal plugs in dry eye syndrome: a pilot study.

    PubMed

    Hadassah, J; Bhuvaneshwari, Namita; Singh, Deepti; Sehgal, P K

    2010-01-01

    This is a pilot study of 10 eyes of 6 patients. This paper describes the preparation and clinical evaluation of succinylated collagen punctal plugs (SCPP) in the treatment of dry eye syndrome (DES). SCPP were prepared from succinylated collagen with the exact dimensions of the punctum (length 1.5-2.5 mm, diameter 0.2-0.5 mm, water content between 50 and 55%). All the patients were clinically evaluated for best corrected visual acuity (BCVA), tear fluid levels (TFL), protein content, tear fluid osmolarity (TFO), fluorescence staining of the cornea and tear break-up time (TBUT) before and after punctal occlusion with SCPP. TFL improved among all the patients after punctal occlusion with SCPP. BCVA showed improvement in case 4 (right eye/left eye), case 5 (left eye) and case 6 (right eye), who had developed dry eyes due to environmental conditions. Protein content increased on day 7 in all the patients and gradually decreased. TFO decreased on days 3 and 5 in all patients after punctal occlusion with SCPP, and showed the same levels on day 14. TFL, PC, TFO and TBUT showed significant improvement in all the patients after punctal occlusion with SCPP. All patients experienced symptomatic relief after punctal occlusion with SCPP. There was no discomfort, foreign body sensation, plug extrusion, corneal aberration, infection, or formation of pyogenic granuloma with SCPP. SCPP stands as a promising alternative to other punctal plugs in the treatment of DES. Copyright 2010 S. Karger AG, Basel.

  3. Distance-Based Tear Lactoferrin Assay on Microfluidic Paper Device Using Interfacial Interactions on Surface-Modified Cellulose.

    PubMed

    Yamada, Kentaro; Henares, Terence G; Suzuki, Koji; Citterio, Daniel

    2015-11-11

    "Distance-based" detection motifs on microfluidic paper-based analytical devices (μPADs) allow quantitative analysis without using signal readout instruments in a similar manner to classical analogue thermometers. To realize a cost-effective and calibration-free distance-based assay of lactoferrin in human tear fluid on a μPAD not relying on antibodies or enzymes, we investigated the fluidic mobilities of the target protein and Tb(3+) cations used as the fluorescent detection reagent on surface-modified cellulosic filter papers. Chromatographic elution experiments in a tear-like sample matrix containing electrolytes and proteins revealed a collapse of attractive electrostatic interactions between lactoferrin or Tb(3+) and the cellulosic substrate, which was overcome by the modification of the paper surface with the sulfated polysaccharide ι-carrageenan. The resulting μPAD based on the fluorescence emission distance successfully analyzed 0-4 mg mL(-1) of lactoferrin in complex human tear matrix with a lower limit of detection of 0.1 mg mL(-1) by simple visual inspection. Assay results of 18 human tear samples including ocular disease patients and healthy volunteers showed good correlation to the reference ELISA method with a slope of 0.997 and a regression coefficient of 0.948. The distance-based quantitative signal and the good batch-to-batch fabrication reproducibility relying on printing methods enable quantitative analysis by simply reading out "concentration scale marks" printed on the μPAD without performing any calibration and using any signal readout instrument.

  4. Lipid order, saturation and surface property relationships: a study of human meibum saturation.

    PubMed

    Mudgil, Poonam; Borchman, Douglas; Yappert, Marta C; Duran, Diana; Cox, Gregory W; Smith, Ryan J; Bhola, Rahul; Dennis, Gary R; Whitehall, John S

    2013-11-01

    Tear film stability decreases with age however the cause(s) of the instability are speculative. Perhaps the more saturated meibum from infants may contribute to tear film stability. The meibum lipid phase transition temperature and lipid hydrocarbon chain order at physiological temperature (33 °C) decrease with increasing age. It is reasonable that stronger lipid-lipid interactions could stabilize the tear film since these interactions must be broken for tear break up to occur. In this study, meibum from a pool of adult donors was saturated catalytically. The influence of saturation on meibum hydrocarbon chain order was determined by infrared spectroscopy. Meibum is in an anhydrous state in the meibomian glands and on the surface of the eyelid. The influence of saturation on the surface properties of meibum was determined using Langmuir trough technology. Saturation of native human meibum did not change the minimum or maximum values of hydrocarbon chain order so at temperatures far above or below the phase transition of human meibum, saturation does not play a role in ordering or disordering the lipid hydrocarbon chains. Saturation did increase the phase transition temperature in human meibum by over 20 °C, a relatively high amount. Surface pressure-area studies showing the late take off and higher maximum surface pressure of saturated meibum compared to native meibum suggest that the saturated meibum film is quite molecularly ordered (stiff molecular arrangement) and elastic (molecules are able to rearrange during compression and expansion) compared with native meibum films which are more fluid agreeing with the infrared spectroscopic results of this study. In saturated meibum, the formation of compacted ordered islands of lipids above the surfactant layer would be expected to decrease the rate of evaporation compared to fluid and more loosely packed native meibum. Higher surface pressure observed with films of saturated meibum compared to native meibum suggests greater film stability especially under the high shear stress of a blink. Copyright © 2013 Elsevier Ltd. All rights reserved.

  5. Oxygen diffusion and edema with modern scleral rigid gas permeable contact lenses.

    PubMed

    Compañ, Vicente; Oliveira, Cristina; Aguilella-Arzo, Marcel; Mollá, Sergio; Peixoto-de-Matos, Sofia C; González-Méijome, José M

    2014-09-04

    We defined the theoretical oxygen tension behind modern scleral contact lenses (CLs) made of different rigid gas permeable (RGP) materials, assuming different thickness of the tear layer behind the lens. A second goal was to show clinically the effect of the postlens tear film on corneal swelling. We simulated the partial pressure of oxygen across the cornea behind scleral CLs made of different lens materials (oxygen permeability Dk, 75-200 barrer) and different thickness (Tav, 100-300 μm). Postlens tear film thicknesses (Tpost-tear) ranging from 150 to 350 μm were considered. Eight healthy subjects were fitted randomly with a scleral lens with a thin and a thick postlens tear layer in two different sessions for a period of 3 hours under open-eye conditions. The CLs with less than 125 barrer of Dk and a thickness over 200 μm depleted the oxygen availability at the lens-cornea interface below 55 mm Hg for a postlens tear film of 150 μm. For a postlens tear film thickness of 350 μm, no combination of material or lens thickness will meet the criteria of 55 mm Hg. Our clinical measures of corneal edema showed that this was significantly higher (P < 0.001, Wilcoxon signed ranks test) with the thicker compared to the thinner Tpost-tear (mean ± SD, 1.66 ± 1.12 vs. 4.27 ± 1.19%). Scleral RGP CLs must be comprised of at least 125 barrer of oxygen permeability and up to 200 μm thick to avoid hypoxic effects even under open eye conditions. Postlens tear film layer should be below 150 μm to avoid clinically significant edema. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.

  6. Wax-tear and meibum protein, wax–β-carotene interactions in vitro using infrared spectroscopy

    PubMed Central

    Faheem, Samad; Kim, Sung-Hye; Nguyen, Jonathan; Neravetla, Shantanu; Ball, Matthew; Foulks, Gary N; Yappert, Marta C; Borchman, Douglas

    2012-01-01

    Protein–meibum and terpenoids–meibum lipid interactions could be important in the etiology of meibomian gland dysfunction (MGD) and dry eye symptoms. In the current model studies, attenuated total reflectance (ATR) infrared (IR) spectroscopy was used to determine if the terpenoid β-carotene and the major proteins in tears and meibum affect the hydrocarbon chain conformation and carbonyl environment of wax, an abundant component of meibum. The main finding of these studies is that mucin binding to wax disordered slightly the conformation of the hydrocarbon chains of wax and caused the wax carbonyls to become hydrogen bonded or experience a more hydrophilic environment. Lysozyme and lactoglobulin, two proteins shown to bind to monolayers of meibum, did not have such an effect. Keratin and β-carotene did not affect the fluidity (viscosity) or environment of the carbonyl moieties of wax. Based on these results, tetraterpenoids are not likely to influence the structure of meibum in the meibomian glands. In addition, these findings suggest that it is unlikely that keratin blocks meibomian glands by causing the meibum to become more viscous. Among the tear fluid proteins studied, mucin is the most likely to influence the conformation and carbonyl environment of meibum at the tear film surface. PMID:22564968

  7. Mucin deficiency causes functional and structural changes of the ocular surface.

    PubMed

    Floyd, Anne M; Zhou, Xu; Evans, Christopher; Rompala, Olivia J; Zhu, Lingxiang; Wang, Mingwu; Chen, Yin

    2012-01-01

    MUC5AC is the most abundant gel-forming mucin in the ocular system. However, the specific function is unknown. In the present study, a Muc5ac knockout (KO) mouse model was subject to various physiological measurements as compared to its wide-type (WT) control. Interestingly, when KO mice were compared to WT mice, the mean tear break up time (TBUT) values were significantly lower and corneal fluorescein staining scores were significantly higher. But the tear volume was not changed. Despite the lack of Muc5ac expression in the conjunctiva of KO mice, Muc5b expression was significantly increased in these mice. Corneal opacification, varying in location and severity, was found in a few KO mice but not in WT mice. The present results suggest a significant difference in the quality, but not the quantity, of tear fluid in the KO mice compared to WT mice. Dry eye disease is multifactorial and therefore further evaluation of the varying components of the tear film, lacrimal unit and corneal structure of these KO mice may help elucidate the role of mucins in dry eye disease. Because Muc5ac knockout mice have clinical features of dry eye, this mouse model will be extremely useful for further studies regarding the pathophysiology of the ocular surface in dry eye in humans.

  8. Acute torn meniscus combined with acute cruciate ligament injury. Second look arthroscopy after 3-month conservative treatment.

    PubMed

    Ihara, H; Miwa, M; Takayanagi, K; Nakayama, A

    1994-10-01

    The purpose of this study was to evaluate arthroscopically the natural healing of an acute torn meniscus combined with an acute cruciate ligament injury treated nonoperatively. There were 30 lateral and 10 medial meniscus tears associated with 25 acute anterior cruciate ligament and 7 posterior cruciate ligament injuries in 32 patients. There was more than 1 tear on some menisci for a total of 51 tear sites. Injuries to the menisci and ligaments were allowed to heal without surgery, but were given protective mobilization immediately in order to stimulate stress oriented healing of injured collagen fibers and promote circulation of synovial fluid to the meniscus and ligament. A Kyuro knee brace with a coil spring traction system was used to add adequate but not excessive stress to the associated injured cruciate ligament. All knees were examined and arthroscoped before and after a 3-month treatment period. Results indicated that 69% of the lateral menisci healed completely and 18% healed partially, whereas 58% of the medial menisci healed completely and none healed partially. Twenty of 25 anterior cruciate ligaments and 3 of 7 posterior cruciate ligaments healed satisfactorily. This study indicated that acute tears of the meniscus, even when they occur in association with a cruciate ligament injury, can heal morphologically with nonsurgical treatment.

  9. Pharmacokinetic Studies of Sustained-Release Depot of Dexamethasone in Beagle Dogs.

    PubMed

    Blizzard, Charles; Desai, Ankita; Driscoll, Arthur

    2016-11-01

    To examine the pharmacokinetic characteristics of sustained-release dexamethasone depots in two separate canine studies. Dexamethasone depots loaded with a clinically representative (0.4 mg) dose (DEXTENZA™; Ocular Therapeutix) or an elevated (0.7 mg) dose were inserted into the canaliculi of beagle eyes (n = 37 and n = 34, respectively). Tear fluid was collected for pharmacokinetic analysis of dexamethasone in both studies at predetermined time points. Explanted 0.4 mg depots were collected weekly to measure remaining drug level. Clinical observations and ophthalmic examinations were performed in both studies at each visit. The 0.4 mg depots released a median 308 μg by day 15 and tapered to complete drug release by day 28. Median dexamethasone tear fluid concentrations in the 0.4 mg study group decreased from 2,805 ng/mL at day 7 to 0 ng/mL on day 28. Median dexamethasone tear fluid concentrations in the 0.7 mg study group decreased from 4,370 ng/mL at 6 h post insertion to 830 ng/mL on day 35. Mean ± standard deviation intraocular pressures in the 0.4 and 0.7 mg study groups were 20.7 ± 2.8 and 19.0 ± 4.1 mmHg at baseline, respectively, and demonstrated no meaningful change (20.5 ± 3.0 and 20.6 ± 2.9 mmHg, respectively) over the studies' durations. No ocular toxicities were attributed to the dexamethasone depot. Sustained-release dexamethasone produced no identifiable ocular toxicity in this animal model, and pharmacokinetics demonstrated a sustained and tapered drug release over 28 days at a 0.4 mg dose and exceeded 35 days at a 0.7 mg dose.

  10. Ocular and systemic pharmacokinetics of lidocaine hydrochloride ophthalmic gel in rabbits after topical ocular administration.

    PubMed

    Liu, Bing; Ding, Li; Xu, Xiaowen; Lin, Hongda; Sun, Chenglong; You, Linjun

    2015-12-01

    Lidocaine hydrochloride ophthalmic gel is a novel ophthalmic preparation for topical ocular anesthesia. The study is aimed at evaluating the ocular and systemic pharmacokinetics of lidocaine hydrochloride 3.5 % ophthalmic gel in rabbits after ocular topical administration. Thirty-six rabbits were randomly placed in 12 groups (3 rabbits per group). The rabbits were quickly killed according to their groups at 0 (predose), 0.0833, 0.167, 0.333, 0.667, 1, 1.5, 2, 3, 4, 6, and 8 h postdose and then the ocular tissue and plasma samples were collected. All the samples were analyzed by a validated LC-MS/MS method. The test result showed that the maximum concentration (C max) of lidocaine in different ocular tissues and plasma were all achieved within 20 min after drug administration, and the data of C max were (2,987 ± 1814) μg/g, (44.67 ± 12.91) μg/g, (26.26 ± 7.19) μg/g, (11,046 ± 2,734) ng/mL, and (160.3 ± 61.0) ng/mL for tear fluid, cornea, conjunctiva, aqueous humor, and plasma, respectively. The data of the elimination half-life in these tissues were 1.5, 3.2, 3.5, 1.9, and 1.7 h for tear fluid, cornea, conjunctiva, aqueous humor, and plasma, respectively. The intraocular lidocaine levels were significantly higher than that in plasma, and the elimination half-life of lidocaine in cornea, conjunctiva, and aqueous humor was relatively longer than that in tear fluid and plasma. The high intraocular penetration, low systemic exposure, and long duration in the ocular tissues suggested lidocaine hydrochloride 3.5 % ophthalmic gel as an effective local anesthetic for ocular anesthesia during ophthalmic procedures.

  11. Passive contribution of the rotator cuff to abduction and joint stability.

    PubMed

    Tétreault, Patrice; Levasseur, Annie; Lin, Jenny C; de Guise, Jacques; Nuño, Natalia; Hagemeister, Nicola

    2011-11-01

    The purpose of this study is to compare shoulder joint biomechanics during abduction with and without intact non-functioning rotator cuff tissue. A cadaver model was devised to simulate the clinical findings seen in patients with a massive cuff tear. Eight full upper limb shoulder specimens were studied. Initially, the rotator cuff tendons were left intact, representing a non-functional rotator cuff, as seen in suprascapular nerve paralysis or in cuff repair with a patch. Subsequently, a massive rotator cuff tear was re-created. Three-dimensional kinematics and force requirements for shoulder abduction were analyzed for each condition using ten abduction cycles in the plane of the scapula. Mediolateral displacements of the glenohumeral rotation center (GHRC) during abduction with an intact non-functioning cuff were minimal, but massive cuff tear resulted in significant lateral displacement of the GHRC (p < 0.013). Similarly, massive cuff tear caused increased superior migration of the GHRC during abduction compared with intact non-functional cuff (p < 0.01). From 5 to 30° of abduction, force requirements were significantly less with an intact non-functioning cuff than with massive cuff tear (p < 0.009). During abduction, an intact but non-functioning rotator cuff resulted in decreased GHRC displacement in two axes as well as lowered the force requirement for abduction from 5 to 30° as compared with the results following a massive rotator cuff tear. This provides insight into the potential biomechanical effect of repairing massive rotator cuff tears with a biological or synthetic "patch," which is a new treatment for massive cuff tear.

  12. Biomechanical analysis of articular-sided partial-thickness rotator cuff tear and repair.

    PubMed

    Mihata, Teruhisa; McGarry, Michelle H; Ishihara, Yoko; Bui, Christopher N H; Alavekios, Damon; Neo, Masashi; Lee, Thay Q

    2015-02-01

    Articular-sided partial-thickness rotator cuff tears are common injuries in throwing athletes. The superior shoulder capsule beneath the supraspinatus and infraspinatus tendons works as a stabilizer of the glenohumeral joint. To assess the effect of articular-sided partial-thickness rotator cuff tear and repair on shoulder biomechanics. The hypothesis was that shoulder laxity might be changed because of superior capsular plication in transtendon repair of articular-sided partial-thickness rotator cuff tears. Controlled laboratory study. Nine fresh-frozen cadaveric shoulders were tested by using a custom shoulder-testing system at the simulated late-cocking phase and acceleration phase of throwing motion. Maximum glenohumeral external rotation angle, anterior translation, position of the humeral head apex with respect to the glenoid, internal impingement area, and glenohumeral and subacromial contact pressures were measured. Each specimen underwent 3 stages of testing: stage 1, with the intact shoulder; stage 2, after creation of articular-sided partial-thickness tears of the supraspinatus and infraspinatus tendons; and stage 3, after transtendon repair of the torn tendons by using 2 suture anchors. Articular-sided partial-thickness tears did not significantly change any of the shoulder biomechanical measurements. In the simulated late-cocking phase, transtendon rotator cuff repair resulted in decreased maximum external rotation angle by 4.2° (P = .03), posterior shift of the humeral head (1.1-mm shift; P = .02), decreased glenohumeral contact pressure by 1.7 MPa (56%; P = .004), and decreased internal impingement area by 26.4 mm(2) (65%; P < .001) compared with values in the torn shoulder. In the acceleration phase, the humeral head shifted inferiorly (1.2-mm shift; P = .03 vs torn shoulder), and glenohumeral anterior translation (1.5-mm decrease; P = .03 vs torn shoulder) and subacromial contact pressure (32% decrease; P = .004 vs intact shoulder) decreased significantly after transtendon repair. Transtendon repair of articular-sided partial-thickness supraspinatus and infraspinatus tears decreased glenohumeral and subacromial contact pressures at time zero; these changes might lead to reduced secondary subacromial and internal impingements and consequently progression to full-thickness rotator cuff tear. However, repair of the tendons decreased anterior translation and external rotation and changed the positional relationship between the humeral head and the glenoid. Careful attention should be paid to shoulder laxity and range of motion when transtendon repair is chosen to treat articular-sided partial-thickness rotator cuff tears, specifically in throwing athletes. © 2014 The Author(s).

  13. A new approach to the linear theory of single-species tearing in two-dimensional quasi-neutral sheets

    NASA Technical Reports Server (NTRS)

    Brittnacher, M.; Quest, K. B.; Karimabadi, H.

    1995-01-01

    We have developed the linear theory of collisionless ion tearing in a two-dimensional magnetotail equilibrium for a single resonant species. We have solved the normal mode problem for tearing instability by an algorithm that employs particle-in-cell simulation to calculate the orbit integrals in the Maxwell-Vlasov eigenmode equation. The results of our single-species tearing analysis can be applied to ion tearing where electron effects are not included. We have calculated the tearing growth rate as a function of the magnetic field component B(sub n) normal to the current sheet for thick and thin current sheets, and we show that marginal stability occurs when the normal gyrofrequency Omega(sub n) is comparable to the Harris neutral sheet growth rate. A cross-tail B(sub y) component has little effect on the growth rate for B(sub y) approximately = B(sub n). Even in the limit B(sub y) much greater than B(sub n), the mode is strongly stabilized by B(sub n). We report than random pitch angle scattering can overcome the stabilizing effect of B(sub n) and drive the growth rate up toward the Harris neutral sheet (B(sub n) = 0) value when the pitch angle diffusion rate is comparable to Omega(sub n).

  14. Paper-based surfaced enhanced Raman spectroscopy for drug level testing with tear fluid

    NASA Astrophysics Data System (ADS)

    Yamada, Kenji; Yokoyama, Moe; Jeong, Hieyong; Kido, Michiko; Ohno, Yuko

    2015-07-01

    The purpose of this study was to show the effectiveness of therapeutic drug level testing by Paper-based Surfaced Enhanced Raman Spectroscopy (PSERS) for artificial lacrimal fluid. We have been used substrates which consist of a common filter paper and gold nano-rods. The targets were Phenobarbital (PB) which dissolved in artificial lacrimal fluid. We measured them using PSERS which the wavelength was 785nm, the power was 30mW. It was found that there were the strong peaks of PB at 997cm-1 and 1026cm-1 which corresponded with solid PB spectral peak for 1mM artificial lacrimal fluid. The results demonstrated the usefulness of this method. It is concluded that our method for therapeutic drug level testing is very efficient.

  15. Gas Bubble Pinch-off in Viscous and Inviscid Liquids

    NASA Astrophysics Data System (ADS)

    Taborek, P.

    2005-11-01

    We have used high-speed video to analyze pinch-off of nitrogen gas bubbles in fluids with a wide range of viscosity. If the external fluid is highly viscous (ηext>100 cP), the radius is proportional to the time before break, τ, and decreases smoothly to zero. If the external fluid has low viscosity (ηext<10 cP), the neck radius scales as &1/2circ; until an instability develops in the gas bubble which causes the neck to rupture and tear apart. Finally, if the viscosity of the external fluid is in an intermediate range, an elongated thread is formed which breaks apart into micron-sized bubbles. 100,000 frame-per-second videos will be presented which illustrate each of these flow regimes.

  16. Investigation of hemodynamics in the development of dissecting aneurysm within patient-specific dissecting aneurismal aortas using computational fluid dynamics (CFD) simulations.

    PubMed

    Tse, Kwong Ming; Chiu, Peixuan; Lee, Heow Pueh; Ho, Pei

    2011-03-15

    Aortic dissecting aneurysm is one of the most catastrophic cardiovascular emergencies that carries high mortality. It was pointed out from clinical observations that the aneurysm development is likely to be related to the hemodynamics condition of the dissected aorta. In order to gain more insight on the formation and progression of dissecting aneurysm, hemodynamic parameters including flow pattern, velocity distribution, aortic wall pressure and shear stress, which are difficult to measure in vivo, are evaluated using numerical simulations. Pulsatile blood flow in patient-specific dissecting aneurismal aortas before and after the formation of lumenal aneurysm (pre-aneurysm and post-aneurysm) is investigated by computational fluid dynamics (CFD) simulations. Realistic time-dependent boundary conditions are prescribed at various arteries of the complete aorta models. This study suggests the helical development of false lumen around true lumen may be related to the helical nature of hemodynamic flow in aorta. Narrowing of the aorta is responsible for the massive recirculation in the poststenosis region in the lumenal aneurysm development. High pressure difference of 0.21 kPa between true and false lumens in the pre-aneurismal aorta infers the possible lumenal aneurysm site in the descending aorta. It is also found that relatively high time-averaged wall shear stress (in the range of 4-8 kPa) may be associated with tear initiation and propagation. CFD modeling assists in medical planning by providing blood flow patterns, wall pressure and wall shear stress. This helps to understand various phenomena in the development of dissecting aneurysm. Copyright © 2011 Elsevier Ltd. All rights reserved.

  17. Biomechanical consequences of a posterior root tear of the lateral meniscus: stabilizing effect of the meniscofemoral ligament.

    PubMed

    Forkel, Philipp; Herbort, Mirco; Schulze, Martin; Rosenbaum, Dieter; Kirstein, Lars; Raschke, Michael; Petersen, Wolf

    2013-05-01

    The purpose of this study was to evaluate the effects of different types of lateral meniscus root tears in terms of tibiofemoral contact stress. Ten porcine knees each underwent five different testing conditions with the menisci intact, a simulated lateral posterior root tear with and without cutting the meniscofemoral ligament and with an artificial tear of the posterior root of the medial meniscus. Biomechanical testing was performed at 30° of flexion with an axial load of 100 N. A pressure sensor (st Sensor Type S2042, Novel, Munich) was used to measure the tibiofemoral contact area and the tibiofemoral contact pressure. Data were analyzed to assess the differences in contact area and tibiofemoral peak contact pressure among the five meniscal conditions. There was no significant difference in mean contact pressure between the state with the menisci intact and an isolated posterior root tear of the lateral meniscus. In case of a root tear and a tear of the meniscofemoral ligament, the contact area decreased in comparison with the intact state of the menisci. After additional cutting of the meniscofemoral ligament, the tibiofemoral contact pressure was significantly higher in comparison with the intact state and the avulsion injury. In the medial compartment, joint compression forces were significantly increased in comparison with the intact state after cutting the posterior root of the medial meniscus (P < 0.05). The consequence of a medial meniscus root tear is well known and was verified by this analysis. The results of the present study show that the biomechanical consequences of a lateral meniscus root tear depend on the state of the meniscofemoral ligament. An increase in tibiofemoral contact pressure is only to be expected in combined injuries of the meniscus root and the meniscofemoral ligaments. Posterior lateral meniscus root tear might have a better prognosis in terms of the development of osteoarthritis when the meniscofemoral ligament is intact.

  18. Bacterial flora of the eye and contact lens. Cases during hydrogel lens wear.

    PubMed

    Callender, M G; Tse, L S; Charles, A M; Lutzi, D

    1986-03-01

    Bacteriological comparisons between the tear fluids of soft contact lens wearers and noncontact lens wearers indicate that there is an increase in the bacterial population in contact lens wearers but not a significant change in the varieties present. Differences between groups of contact lens wearers appear to depend on the method of disinfection used.

  19. Three-Dimensional Simulations of Tearing and Intermittency in Coronal Jets

    NASA Technical Reports Server (NTRS)

    Wyper, P. F.; DeVore, C. R.; Karpen, J. T.; Lynch, B. J.

    2016-01-01

    Observations of coronal jets increasingly suggest that local fragmentation and intermittency play an important role in the dynamics of these events. In this work we investigate this fragmentation in high-resolution simulations of jets in the closed-field corona. We study two realizations of the embedded-bipole model, whereby impulsive helical out flows are driven by reconnection between twisted and untwisted field across the domed fan plane of a magnetic null. We find that the reconnection region fragments following the onset of a tearing-like instability, producing multiple magnetic null points and flux-rope structures within the current layer. The flux ropes formed within the weak- field region in the center of the current layer are associated with \\blobs" of density enhancement that become filamentary threads as the flux ropes are ejected from the layer, whereupon new flux ropes form behind them. This repeated formation and ejection of flux ropes provides a natural explanation for the intermittent out flows, bright blobs of emission, and filamentary structure observed in some jets. Additional observational signatures of this process are discussed. Essentially all jet models invoke reconnection between regions of locally closed and locally open field as the jet-generation mechanism. Therefore, we suggest that this repeated tearing process should occur at the separatrix surface between the two flux systems in all jets. A schematic picture of tearing-mediated jet reconnection in three dimensions is outlined.

  20. THREE-DIMENSIONAL SIMULATIONS OF TEARING AND INTERMITTENCY IN CORONAL JETS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wyper, P. F.; DeVore, C. R.; Karpen, J. T.

    Observations of coronal jets increasingly suggest that local fragmentation and intermittency play an important role in the dynamics of these events. In this work, we investigate this fragmentation in high-resolution simulations of jets in the closed-field corona. We study two realizations of the embedded-bipole model, whereby impulsive helical outflows are driven by reconnection between twisted and untwisted field across the domed fan plane of a magnetic null. We find that the reconnection region fragments following the onset of a tearing-like instability, producing multiple magnetic null points and flux-rope structures within the current layer. The flux ropes formed within the weak-fieldmore » region in the center of the current layer are associated with “blobs” of density enhancement that become filamentary threads as the flux ropes are ejected from the layer, whereupon new flux ropes form behind them. This repeated formation and ejection of flux ropes provides a natural explanation for the intermittent outflows, bright blobs of emission, and filamentary structure observed in some jets. Additional observational signatures of this process are discussed. Essentially all jet models invoke reconnection between regions of locally closed and locally open field as the jet-generation mechanism. Therefore, we suggest that this repeated tearing process should occur at the separatrix surface between the two flux systems in all jets. A schematic picture of tearing-mediated jet reconnection in three dimensions is outlined.« less

  1. Linear tearing mode stability equations for a low collisionality toroidal plasma

    NASA Astrophysics Data System (ADS)

    Connor, J. W.; Hastie, R. J.; Helander, P.

    2009-01-01

    Tearing mode stability is normally analysed using MHD or two-fluid Braginskii plasma models. However for present, or future, large hot tokamaks like JET or ITER the collisionality is such as to place them in the banana regime. Here we develop a linear stability theory for the resonant layer physics appropriate to such a regime. The outcome is a set of 'fluid' equations whose coefficients encapsulate all neoclassical physics: the neoclassical Ohm's law, enhanced ion inertia, cross-field transport of particles, heat and momentum all play a role. While earlier treatments have also addressed this type of neoclassical physics we differ in incorporating the more physically relevant 'semi-collisional fluid' regime previously considered in cylindrical geometry; semi-collisional effects tend to screen the resonant surface from the perturbed magnetic field, preventing reconnection. Furthermore we also include thermal physics, which may modify the results. While this electron description is of wide relevance and validity, the fluid treatment of the ions requires the ion banana orbit width to be less than the semi-collisional electron layer. This limits the application of the present theory to low magnetic shear—however, this is highly relevant to the sawtooth instability—or to colder ions. The outcome of the calculation is a set of one-dimensional radial differential equations of rather high order. However, various simplifications that reduce the computational task of solving these are discussed. In the collisional regime, when the set reduces to a single second-order differential equation, the theory extends previous work by Hahm et al (1988 Phys. Fluids 31 3709) to include diamagnetic-type effects arising from plasma gradients, both in Ohm's law and the ion inertia term of the vorticity equation. The more relevant semi-collisional regime pertaining to JET or ITER, is described by a pair of second-order differential equations, extending the cylindrical equations of Drake et al (1983 Phys. Fluids 26 2509) to toroidal geometry.

  2. Keratoconus: an inflammatory disorder?

    PubMed Central

    Galvis, V; Sherwin, T; Tello, A; Merayo, J; Barrera, R; Acera, A

    2015-01-01

    Keratoconus has been classically defined as a progressive, non-inflammatory condition, which produces a thinning and steepening of the cornea. Its pathophysiological mechanisms have been investigated for a long time. Both genetic and environmental factors have been associated with the disease. Recent studies have shown a significant role of proteolytic enzymes, cytokines, and free radicals; therefore, although keratoconus does not meet all the classic criteria for an inflammatory disease, the lack of inflammation has been questioned. The majority of studies in the tears of patients with keratoconus have found increased levels of interleukin-6 (IL-6), tumor necrosis factor-α(TNF-α), and matrix metalloproteinase (MMP)-9. Eye rubbing, a proven risk factor for keratoconus, has been also shown recently to increase the tear levels of MMP-13, IL-6, and TNF-α. In the tear fluid of patients with ocular rosacea, IL-1α and MMP-9 have been reported to be significantly elevated, and cases of inferior corneal thinning, resembling keratoconus, have been reported. We performed a literature review of published biochemical changes in keratoconus that would support that this could be, at least in part, an inflammatory condition. PMID:25931166

  3. Tearing mode dynamics in the RFX-mod tokamak

    NASA Astrophysics Data System (ADS)

    Cordaro, Luigi; Zanca, Paolo; Zuin, Matteo; Auriemma, Fulvio; Martines, Emilio; Zaniol, Barbara; Pucella, Gianluca; Cavazzana, Roberto; de Masi, Gianluca; Fassina, Alessandro; Grenfell, Gustavo; Momo, Barbara; Spagnolo, Silvia; Spolaore, Monica; Vianello, Nicola

    2017-10-01

    The study of the physical mechanisms that influence the tearing mode (TM) rotation is of interest because, while in present day devices, a significant TM rotation can be induced by Neutral Beam Injection, future reactors, ITER included, are not expected to provide enough induced momentum. We present a study of tearing mode dynamics in the RFX-mod device, a Reserved Field Pinch in Padua (Italy) that can be run as low-current, circular tokamak. Magnetic, flow and kinetic measurements are integrated to characterize the (2,1) and (3,2) TMs fast rotation. We are especially interested to study the role played by the diamagnetic electron drift on the TM rotation, including the slowing down and the wall-locking phases. When the latter occurs, the radial magnetic field penetrates the shell and the TM amplitude increases at a rate given by the wall resistive time constant. This phenomenon can lead to a rapid discharge termination via a disruption. A comparison of experimental data with a two-fluid MHD cylindrical model has been used to interpret the observed TM fast rotation frequencies.

  4. Influence of rotator cuff tears on glenohumeral stability during abduction tasks.

    PubMed

    Hölscher, Thomas; Weber, Tim; Lazarev, Igor; Englert, Carsten; Dendorfer, Sebastian

    2016-09-01

    One of the main goals in reconstructing rotator cuff tears is the restoration of glenohumeral joint stability, which is subsequently of utmost importance in order to prevent degenerative damage such as superior labral anterior posterior (SLAP) lesion, arthrosis, and malfunction. The goal of the current study was to facilitate musculoskeletal models in order to estimate glenohumeral instability introduced by muscle weakness due to cuff lesions. Inverse dynamics simulations were used to compute joint reaction forces for several static abduction tasks with different muscle weakness. Results were compared with the existing literature in order to ensure the model validity. Further arm positions taken from activities of daily living, requiring the rotator cuff muscles were modeled and their contribution to joint kinetics computed. Weakness of the superior rotator cuff muscles (supraspinatus; infraspinatus) leads to a deviation of the joint reaction force to the cranial dorsal rim of the glenoid. Massive rotator cuff defects showed higher potential for glenohumeral instability in contrast to single muscle ruptures. The teres minor muscle seems to substitute lost joint torque during several simulated muscle tears to maintain joint stability. Joint instability increases with cuff tear size. Weakness of the upper part of the rotator cuff leads to a joint reaction force closer to the upper glenoid rim. This indicates the comorbidity of cuff tears with SLAP lesions. The teres minor is crucial for maintaining joint stability in case of massive cuff defects and should be uprated in clinical decision-making. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 34:1628-1635, 2016. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  5. Biomechanical effect of latissimus dorsi tendon transfer for irreparable massive cuff tear.

    PubMed

    Oh, Joo Han; Tilan, Justin; Chen, Yu-Jen; Chung, Kyung Chil; McGarry, Michelle H; Lee, Thay Q

    2013-02-01

    The purpose of this study was to determine the biomechanical effects of latissimus dorsi transfer in a cadaveric model of massive posterosuperior rotator cuff tear. Eight cadaveric shoulders were tested at 0°, 30°, and 60° of abduction in the scapular plane with anatomically based muscle loading. Humeral rotational range of motion and the amount of humeral rotation due to muscle loading were measured. Glenohumeral kinematics and contact characteristics were measured throughout the range of motion. After testing in the intact condition, the supraspinatus and infraspinatus were resected. The cuff tear was then repaired by latissimus dorsi transfer. Two muscle loading conditions were applied after latissimus transfer to simulate increased tension that may occur due to limited muscle excursion. A repeated-measures analysis of variance was used for statistical analysis. The amount of internal rotation due to muscle loading and maximum internal rotation increased with massive cuff tear and was restored with latissimus transfer (P < .05). At maximum internal rotation, the humeral head apex shifted anteriorly, superiorly, and laterally at 0° of abduction after massive cuff tear (P < .05); this abnormal shift was corrected with latissimus transfer (P < .05). However, at 30° and 60° of abduction, latissimus transfer significantly altered kinematics (P < .05) and latissimus transfer with increased muscle loading increased contact pressure, especially at 60° of abduction. Latissimus dorsi transfer is beneficial in restoring humeral internal/external rotational range of motion, the internal/external rotational balance of the humerus, and glenohumeral kinematics at 0° of abduction. However, latissimus dorsi transfer with simulated limited excursion may lead to an overcompensation that can further deteriorate normal biomechanics, especially at higher abduction angles. Published by Mosby, Inc.

  6. Influence of asymmetric magnetic perturbation on the nonlinear evolution of double tearing modes

    NASA Astrophysics Data System (ADS)

    Xiong, G. Z.; Wang, L.; Li, X. Q.; Liu, H. F.; Tang, C. J.; Huang, J.; Zhang, X.; Wang, X. Q.

    2017-06-01

    The effects of asymmetric magnetic perturbation on the triggering and evolution of double tearing modes (DTMs) are investigated using nonlinear magnetohydrodynamics simulations in a slab geometry. We find that for reversed magnetic shear plasmas the resistive reconnection process induced by the initial perturbation at one rational surface can drive a new island at the other rational surface with the same mode number. The four typical states of the mode for the time evolution are found, and include: (i) a linear growth stage; (ii) a linear/nonlinear stable stage; (iii) an interactively driving stage; and (iv) a symmetric DTM stage. These differ from previous simulation results. Moreover, nonlinear DTM growth is found to strongly depend on the asymmetric magnetic perturbation, particularly in the early nonlinear phase. The initial perturbation strength scale of island width suggests that the left island enters into a Sweet-Parker growth process when the right island is sufficiently large to effectively drive the other. These results predict that although externally applied magnetic perturbations can suppress the neoclassical tearing mode they can also trigger new instabilities such as asymmetric DTMs.

  7. Internal Shocks in the Magnetic Reconnection Jet in Solar Flares: Multiple Fast Shocks Created by the Secondary Tearing Instability

    NASA Astrophysics Data System (ADS)

    Tanuma, S.; Shibata, K.

    2005-07-01

    Space solar missions such as Yohkoh and RHESSI observe the hard X- and gamma-ray emission from energetic electrons in impulsive solar flares. Their energization mechanism, however, is unknown. In this Letter, we suggest that the internal shocks are created in the reconnection jet and that they are possible sites of particle acceleration. We examine how magnetic reconnection creates the multiple shocks by performing two-dimensional resistive magnetohydrodynamic simulations. In this Letter, we use a very small grid to resolve the diffusion region. As a result, we find that the current sheet becomes thin due to the tearing instability, and it collapses to a Sweet-Parker sheet. The thin sheet becomes unstable to the secondary tearing instability. Fast reconnection starts by the onset of anomalous resistivity immediately after the secondary tearing instability. During the bursty, time-dependent magnetic reconnection, the secondary tearing instability continues in the diffusion region where the anomalous resistivity is enhanced. As a result, many weak shocks are created in the reconnection jet. This situation produces turbulent reconnection. We suggest that multiple fast shocks are created in the jet and that the energetic electrons can be accelerated by these shocks.

  8. Nonlinear evolution of three-dimensional instabilities of thin and thick electron scale current sheets: Plasmoid formation and current filamentation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jain, Neeraj; Büchner, Jörg; Max Planck Institute for Solar System Research, Justus-Von-Liebig-Weg-3, Göttingen

    Nonlinear evolution of three dimensional electron shear flow instabilities of an electron current sheet (ECS) is studied using electron-magnetohydrodynamic simulations. The dependence of the evolution on current sheet thickness is examined. For thin current sheets (half thickness =d{sub e}=c/ω{sub pe}), tearing mode instability dominates. In its nonlinear evolution, it leads to the formation of oblique current channels. Magnetic field lines form 3-D magnetic spirals. Even in the absence of initial guide field, the out-of-reconnection-plane magnetic field generated by the tearing instability itself may play the role of guide field in the growth of secondary finite-guide-field instabilities. For thicker current sheetsmore » (half thickness ∼5 d{sub e}), both tearing and non-tearing modes grow. Due to the non-tearing mode, current sheet becomes corrugated in the beginning of the evolution. In this case, tearing mode lets the magnetic field reconnect in the corrugated ECS. Later thick ECS develops filamentary structures and turbulence in which reconnection occurs. This evolution of thick ECS provides an example of reconnection in self-generated turbulence. The power spectra for both the thin and thick current sheets are anisotropic with respect to the electron flow direction. The cascade towards shorter scales occurs preferentially in the direction perpendicular to the electron flow.« less

  9. Mucin Deficiency Causes Functional and Structural Changes of the Ocular Surface

    PubMed Central

    Evans, Christopher; Rompala, Olivia J.; Zhu, Lingxiang; Wang, Mingwu; Chen, Yin

    2012-01-01

    MUC5AC is the most abundant gel-forming mucin in the ocular system. However, the specific function is unknown. In the present study, a Muc5ac knockout (KO) mouse model was subject to various physiological measurements as compared to its wide-type (WT) control. Interestingly, when KO mice were compared to WT mice, the mean tear break up time (TBUT) values were significantly lower and corneal fluorescein staining scores were significantly higher. But the tear volume was not changed. Despite the lack of Muc5ac expression in the conjunctiva of KO mice, Muc5b expression was significantly increased in these mice. Corneal opacification, varying in location and severity, was found in a few KO mice but not in WT mice. The present results suggest a significant difference in the quality, but not the quantity, of tear fluid in the KO mice compared to WT mice. Dry eye disease is multifactorial and therefore further evaluation of the varying components of the tear film, lacrimal unit and corneal structure of these KO mice may help elucidate the role of mucins in dry eye disease. Because Muc5ac knockout mice have clinical features of dry eye, this mouse model will be extremely useful for further studies regarding the pathophysiology of the ocular surface in dry eye in humans. PMID:23272068

  10. Computer Simulation Studies of the Tearing Mode Instability in a Field-Reversed Ion Layer.

    DTIC Science & Technology

    1980-09-15

    CLASSIFICATION OF THIS PAGE (when Date Entered) 20. (Abstract continued) .those of the linear theory. In addition, it has been demonstrated that when...However, all the results obtained so far are very encouraging. Using the energy prin- ciple Sudan and Rosenbluth5 have shown with a hybrid model that a...found that finite length layers are stable to tearing modes as a consequence of axial kinetic pressure. Using a hybrid model , in which the ion layer is

  11. Progress in theoretical and numerical modeling of RF/MHD coupling using NIMROD

    NASA Astrophysics Data System (ADS)

    Jenkins, Thomas G.; Schnack, Dalton D.; Hegna, Chris C.; Callen, James D.; Sovinec, Carl R.; Held, Eric D.; Ji, Jeong-Young; Kruger, Scott E.

    2007-11-01

    Preliminary work relevant to the development of a general framework for the self-consistent inclusion of RF effects in fluid codes is presented; specifically, the stabilization of neoclassical and conventional tearing modes by electron cyclotron current drive is considered. For this particular problem, the effects of the RF drive can be formally captured by a quasilinear diffusion operator which enters the fluid equations on the same footing as the collision operator. Furthermore, a Chapman-Enskog-like method can be used to determine the consequent effects of the RF drive on the fluid closures for the parallel heat flow and stress. We summarize our recent research along these lines and discuss issues relevant to its implementation in the NIMROD code.

  12. Advances in the analysis of "less-conventional" human body fluids: An overview of the CE- and HPLC-MS applications in the years 2015-2017.

    PubMed

    Di Venere, Monica; Viglio, Simona; Cagnone, Maddalena; Bardoni, Anna; Salvini, Roberta; Iadarola, Paolo

    2018-01-01

    Aim of this article is to focus the attention of the reader on the application of CE/MS and LC/MS to the analysis of human body fluids not currently used for the diagnosis of disorders and, for this reason, catalogued as "less/nonconventional" fluids, that is, tears, nasal secretions, cerumen, bronchoalveolar lavage fluid, sputum, exhaled breath condensate, nipple aspirate, breast milk, amniotic fluid, bile, seminal plasma, liposuction aspirate fluid, and synovial fluid. The pool of articles presented in this report demonstrates that, rather than being neglected, these fluids are an important resource for the evaluation of possible pathologic conditions. Thus, being a sort of mirror that reflects the normal internal characteristics and disease state of an individual, they benefit of an increasing appreciation. This review follows a previous report of this series and covers the latest developments in this field that have been published in specialist journals in the years 2015-2017. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Sweating the small stuff: Glycoproteins in human sweat and their unexplored potential for microbial adhesion.

    PubMed

    Peterson, Robyn A; Gueniche, Audrey; Adam de Beaumais, Ségolène; Breton, Lionel; Dalko-Csiba, Maria; Packer, Nicolle H

    2016-03-01

    There is increasing evidence that secretory fluids such as tears, saliva and milk play an important role in protecting the human body from infection via a washing mechanism involving glycan-mediated adhesion of potential pathogens to secretory glycoproteins. Interaction of sweat with bacteria is well established as the cause of sweat-associated malodor. However, the role of sweat glycoproteins in microbial attachment has received little, if any, research interest in the past. In this review, we demonstrate how recent published studies involving high-throughput proteomic analysis have inadvertently, and fortuitously, exposed an abundance of glycoproteins in sweat, many of which have also been identified in other secretory fluids. We bring together research demonstrating microbial adhesion to these secretory glycoproteins in tears, saliva and milk and suggest a similar role of the sweat glycoproteins in mediating microbial attachment to sweat and/or skin. The contribution of glycan-mediated microbial adhesion to sweat glycoproteins, and the associated impact on sweat derived malodor and pathogenic skin infections are unchartered new research areas that we are beginning to explore. © The Author 2015. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  14. Capabilities of Fully Parallelized MHD Stability Code MARS

    NASA Astrophysics Data System (ADS)

    Svidzinski, Vladimir; Galkin, Sergei; Kim, Jin-Soo; Liu, Yueqiang

    2016-10-01

    Results of full parallelization of the plasma stability code MARS will be reported. MARS calculates eigenmodes in 2D axisymmetric toroidal equilibria in MHD-kinetic plasma models. Parallel version of MARS, named PMARS, has been recently developed at FAR-TECH. Parallelized MARS is an efficient tool for simulation of MHD instabilities with low, intermediate and high toroidal mode numbers within both fluid and kinetic plasma models, implemented in MARS. Parallelization of the code included parallelization of the construction of the matrix for the eigenvalue problem and parallelization of the inverse vector iterations algorithm, implemented in MARS for the solution of the formulated eigenvalue problem. Construction of the matrix is parallelized by distributing the load among processors assigned to different magnetic surfaces. Parallelization of the solution of the eigenvalue problem is made by repeating steps of the MARS algorithm using parallel libraries and procedures. Parallelized MARS is capable of calculating eigenmodes with significantly increased spatial resolution: up to 5,000 adapted radial grid points with up to 500 poloidal harmonics. Such resolution is sufficient for simulation of kink, tearing and peeling-ballooning instabilities with physically relevant parameters. Work is supported by the U.S. DOE SBIR program.

  15. Resection of Grade III cranial horn tears of the equine medial meniscus alter the contact forces on medial tibial condyle at full extension: an in-vitro cadaveric study.

    PubMed

    Fowlie, Jennifer; Arnoczky, Steven; Lavagnino, Michael; Maerz, Tristan; Stick, John

    2011-12-01

    To evaluate the magnitude and distribution of joint contact pressure on the medial tibial condyle after grade III cranial horn tears of the medial meniscus. Experimental study. Cadaveric equine stifles (n = 6). Cadaveric stifles were mounted in a materials testing system and electronic pressure sensors were placed between the medial tibial condyle and medial meniscus. Specimens were loaded parallel to the longitudinal axis of the tibia to 1800 N at 130°, 140°, 150°, and 160° stifle angle. Peak pressure and contact area were recorded from the contact maps. Testing was repeated after surgical creation of a grade III cranial horn tear of the medial meniscus, and after resection of the simulated tear. In the intact specimens, a significantly smaller contact area was observed at 160° compared with the other angles (P < .05). Creation of a grade III cranial horn tear in the medial meniscus did not significantly alter the pressure or contact area measurements at any stifle angle compared with intact specimens (P > .05). Resection of the tear resulted in significantly higher peak pressures in the central region of the medial tibial condyle at a stifle angle of 160° relative to the intact (P = .026) and torn (P = .012) specimens. Resection of grade III cranial horn tears in the medial meniscus resulted in a central focal region of increased pressure on the medial tibial condyle at 160° stifle angle. © Copyright 2011 by The American College of Veterinary Surgeons.

  16. Effect of Radiation on Chromospheric Magnetic Reconnection: Reactive and Collisional Multi-fluid Simulations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Alvarez Laguna, A.; Poedts, S.; Lani, A.

    We study magnetic reconnection under chromospheric conditions in five different ionization levels from 0.5% to 50% using a self-consistent two-fluid (ions + neutrals) model that accounts for compressibility, collisional effects, chemical inequilibrium, and anisotropic heat conduction. Results with and without radiation are compared, using two models for the radiative losses: an optically thin radiation loss function, and an approximation of the radiative losses of a plasma with photospheric abundances. The results without radiation show that reconnection occurs faster for the weakly ionized cases as a result of the effect of ambipolar diffusion and fast recombination. The tearing mode instability appearsmore » earlier in the low ionized cases and grows rapidly. We find that radiative losses have a stronger effect than was found in previous results as the cooling changes the plasma pressure and the concentration of ions inside the current sheet. This affects the ambipolar diffusion and the chemical equilibrium, resulting in thin current sheets and enhanced reconnection. The results quantify this complex nonlinear interaction by showing that a strong cooling produces faster reconnections than have been found in models without radiation. The results accounting for radiation show timescales and outflows comparable to spicules and chromospheric jets.« less

  17. Release of Membrane-associated Mucins from Ocular Surface Epithelia

    PubMed Central

    Blalock, Timothy D.; Spurr-Michaud, Sandra J.; Tisdale, Ann S.; Gipson, Ilene K.

    2008-01-01

    Purpose Three membrane-associated mucins (MAMs)—MUC1, MUC4 and MUC16—are expressed at the ocular surface epithelium. Soluble forms of MAMs are detected in human tears, but the mechanisms of their release from the apical cells are unknown. The purpose of this study was to identify physiologic agents that induce ocular surface MAM release. Methods An immortalized human corneal-limbal epithelial cell line (HCLE) expressing the same MAMs as native tissue was used. An antibody specific to MUC16’s cytoplasmic tail was developed to confirm that only the extracellular domain is released into the tear fluid or culture media. Effects of agents that have been shown to be present in tears or are implicated in release/shedding of MAMs in other epithelia (neutrophil elastase, tumor necrosis factor (TNF), TNF-α-converting enzyme, and matrix metalloproteinases-7 and –9) were assessed on HCLE cells. HCLE cell surface proteins were biotinylated to measure efficiency of induced MAM release and surface restoration. Effects of induced release on surface barrier function were measured by rose bengal dye penetrance. Results MUC16 in tears and in HCLE-conditioned medium lacked the cytoplasmic tail. TNF induced release of MUC1, MUC4, and MUC16 from the HCLE surface. Matrix metalloproteinase-7 and neutrophil elastase induced release of MUC16 but not MUC1 or MUC4. Neutrophil elastase removed 68% of MUC16—78% of which was restored to the HCLE cell surface 24 hours after release. Neutrophil elastase-treated HCLE cells showed significantly reduced rose bengal dye exclusion. Conclusions Results suggest that extracellular domains of MUC1, 4, and 16 can be released from the ocular surface by agents present in tears. Neutrophil elastase and TNF present in higher amounts in dry eye patients’ tears may cause MAM release—allowing rose bengal staining. PMID:18436821

  18. Response of vascular pigment epithelium detachment due to age-related macular degeneration to monthly treatment with ranibizumab: the prospective, multicentre RECOVER study.

    PubMed

    Clemens, Christoph R; Wolf, Armin; Alten, Florian; Milojcic, Carolin; Heiduschka, Peter; Eter, Nicole

    2017-11-01

    To assess the effects of monthly intravitreal ranibizumab injections in patients with vascularized pigment epithelium detachment (vPED) secondary to age-related macular degeneration (AMD). A total of 40 patients were prospectively observed and treated monthly with 0.5 mg ranibizumab injections (ClinicalTrials.gov Ident. NCT00976222). Inclusion criterion was a treatment-naïve vPED lesion with a minimum height of ≥200 μm. Best-corrected visual acuity (BCVA) and spectral-domain optical coherence tomography (SD-OCT) were evaluated at all visits. Fluorescein angiography and indocyanine green angiography were performed at baseline and quarterly. Lesions were differentiated between serous vascular PED (svPED, group A, 29 patients) and fibrovascular PED (fPED, group B, 11 patients). Primary outcome was the effectivity of continuous monthly treatment during a 12-month period as measured in change in BCVA. Secondary outcomes were change in PED height and PED greatest linear diameter (GLD). Further secondary outcomes were the presence of subretinal fluid and prognostic markers of an impending retinal pigment epithelium (RPE) tear: PED lesion height and diameter, ratio of choroidal neovascularization (CNV) size to PED size, hyperreflective lines in near-infrared images, microrips and subretinal cleft. Mean BCVA was 56.9 ± 11.5 letters (A: 55.4 ± 10.8; B: 59.1 ± 13.4) at baseline and 55.1 ± 15.9 (A: 53.7 ± 17.0; B: 58.9 ± 12.7) at 12-month follow-up. Excluding the RPE tear patients, the svPED group showed an increase in BCVA from 56.1 ± 10.3 at baseline to 62.4 ± 10.2 at 12-month follow-up (p = 0.048). Best-corrected visual acuity in patient who developed a RPE tear was 55.8 ± 12.5 at baseline and 37.1 ± 14.9 at 12-month follow-up. The mean change in PED height was -242.1 μm ± 285.5 (A: -427.3 μm ± 299.7; B: -51.6 μm ± 99.5). The mean decrease in PED GLD was -471.8 μm ± 727.6 (A: -738.9 μm ± 788.2; B: -10.4 μm ± 185.6). In group A, 10 patients developed a RPE tear (25%) after a mean of 3.6 injections. No tear was documented in group B. Lesion height, ratio of CNV size to PED size and presence of hyperreflective lines differed significantly between patients with and without RPE tear development. Serous vascular PED lesions showed an improvement regarding BCVA and morphologic characteristics unless an RPE tear occurred. In fPED lesions, a functional and morphological stabilization was observed. Monthly ranibizumab injections are an effective treatment regarding the resorption of subretinal fluid in vPED due to AMD. Patients should be screened for the presence of morphologic risk factors for RPE tear development before and during treatment. © 2017 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  19. Evaluation of the transforming growth factor-beta activity in normal and dry eye human tears by CCL-185 cell bioassay.

    PubMed

    Zheng, Xiaofen; De Paiva, Cintia S; Rao, Kavita; Li, De-Quan; Farley, William J; Stern, Michael; Pflugfelder, Stephen C

    2010-09-01

    To develop a new bioassay method using human lung epithelial cells (CCL-185) to assess activity of transforming growth factor beta (TGF-beta) in human tear fluid from normal subjects and patients with dry eye. Two epithelial cell lines, mink lung cells (CCL-64) and human lung cells (CCL-185), were compared to detect the active form of TGF-beta by BrdU incorporation (quantitation of cell DNA synthesis) and WST assay (metabolic activity of viable cells). The effect of TGF-beta on the growth of CCL-185 cells was observed microscopically. Human tears from normal control subjects and patients with dry eye (DE) with and without Sjögren syndrome were evaluated for TGF-beta concentration by Luminex microbead assay, and TGF-beta activity by the CCL-185 cell growth inhibition bioassay. The metabolic activity of viable CCL-185 cells, measured by WST, was shown to be proportional to the TGF-beta1 concentration (R = 0.919) and confirmed by BrdU assay (R = 0.969). Compared with CCL-185, metabolic activity of viable cells and DNA synthesis, measured by WST and BrdU incorporation assays, were shown to be less proportional to the TGF-beta1 concentration in the CCL-64 line (R = 0.42 and 0.17, respectively). Coincubation with human anti-TGF-beta1 antibody (MAB-240) yielded a dose-dependent inhibition of TGF-beta1 (0.3 ng/mL) activity. CCL-185 cell growth observed microscopically was noted to decrease in response to increasing TGF-beta1 concentrations. Levels of immuodetectable TGF-beta1 and TGF-beta2 were similar in normal and DE tears. TGF-beta bioactivity in DE human tears measured by the CCL-185 cells assay was found to be higher (9777.5 +/- 10481.9 pg/mL) than those in normal controls (4129.3 +/- 1342.9 pg/mL) (P < 0.05). Among patients with DE, TGF-beta bioactivity was highest in those with Sjögren syndrome. Approximately, 79.1% of TGF-beta in DE tears and 37.6% TGF-beta in normal tears were found to be biologically active. The CCL-185 cell assay was found to be a suitable tool for assessing TGF-beta activity in human tears. Tear TGF-beta bioactivity increases in DE, particularly in Sjögren syndrome, where elevated levels of TGF-beta1 transcripts in the conjunctival epithelium have been previously detected.

  20. The effect of complete radial lateral meniscus posterior root tear on the knee contact mechanics: a finite element analysis.

    PubMed

    Bao, H R C; Zhu, D; Gong, H; Gu, G S

    2013-03-01

    In recent years, with technological advances in arthroscopy and magnetic resonance imaging and improved biomechanical studies of the meniscus, there has been some progress in the diagnosis and treatment of injuries to the roots of the meniscus. However, the biomechanical effect of posterior lateral meniscus root tears on the knee has not yet become clear. The purpose of this study was to determine the effect of a complete radial posterior lateral meniscus root tear on the knee contact mechanics and the function of the posterior meniscofemoral ligament on the knee with tear in the posterior root of lateral meniscus. A finite element model of the knee was developed to simulate different cases for intact knee, a complete radial posterior lateral meniscus root tear, a complete radial posterior lateral meniscus root tear with posterior meniscofemoral ligament deficiency, and total meniscectomy of the lateral meniscus. A compressive load of 1000 N was applied in all cases to calculate contact areas, contact pressure, and meniscal displacements. The complete radial posterior lateral meniscus root tear decreased the contact area and increased the contact pressure on the lateral compartment under compressive load. We also found a decreased contact area and increased contact pressure in the medial compartment, but it was not obvious compared to the lateral compartment. The lateral meniscus was radially displaced by compressive load after a complete radial posterior lateral meniscus root tear, and the displacement took place mainly in the body and posterior horn of lateral meniscus. There were further decrease in contact area and increases in contact pressure and raidial displacement of the lateral meniscus in the case of the complete posterior lateral meniscus root tear in combination with posterior meniscofemoral ligament deficiency. Complete radial posterior lateral meniscus root tear is not functionally equivalent to total meniscectomy. The posterior root torn lateral meniscus continues to provide some load transmission and distribution functions across the joint. The posterior meniscofemoral ligament prevents excessive radial displacement of the posterior root torn lateral meniscus and assists the torn lateral meniscus in transmitting a certain amount of stress in the lateral compartment.

  1. The role of biomaterials in the treatment of meniscal tears

    PubMed Central

    Brown, Robert J.

    2017-01-01

    Extensive investigations over the recent decades have established the anatomical, biomechanical and functional importance of the meniscus in the knee joint. As a functioning part of the joint, it serves to prevent the deterioration of articular cartilage and subsequent osteoarthritis. To this end, meniscus repair and regeneration is of particular interest from the biomaterial, bioengineering and orthopaedic research community. Even though meniscal research is previously of a considerable volume, the research community with evolving material science, biology and medical advances are all pushing toward emerging novel solutions and approaches to the successful treatment of meniscal difficulties. This review presents a tactical evaluation of the latest biomaterials, experiments to simulate meniscal tears and the state-of-the-art materials and strategies currently used to treat tears. PMID:29158995

  2. The effect of rebamipide ophthalmic suspension on ocular surface mucins in soft contact lens wearers.

    PubMed

    Shigeyasu, Chika; Yamada, Masakazu; Akune, Yoko; Fukui, Masaki

    2017-12-13

    To evaluate the changes in ocular surface mucins with 2%rebamipide ophthalmic suspension treatment in soft contact lens (SCL) wearers. Rebamipide suspension is a mucin secretagogue approved for the treatment of dry eye syndrome in Japan. In this study, the fluorescence intensity of wheat germ agglutinin conjugate of fluorescein (F-WGA) was used as a marker of membrane-associated mucins, and sialic acid concentration in tear fluids as a marker of secreted mucins. Thirty-two eyes of 16 SCL wearers with discomfort were treated with rebamipide suspension at a dose of one drop in each eye four times daily for two weeks. The parameters of clinical efficacy were tear break-up time, fluorescein staining scores for the cornea and conjunctiva, and Schirmer test values. Fluorescence intensities in the central cornea were measured by fluorophotometry after the application of 5% F-WGA solution. Tears collected by Schirmer test strips were analyzed by high-performance liquid chromatography, and the concentrations of sialic acid, total protein, and the four major tear proteins, namely secretory IgA, lactoferrin, lipocalin-1, and lysozyme were measured. Significant increases in F-WGA fluorescence intensities (p < 0.005) were seen in the corneal surfaces. Sialic acid concentrations increased over time; however, the differences were not statistically significant. Except for a slight increase in kerato-conjunctival staining scores (p < 0.05) and secretory IgA (p < 0.05), no other significant differences were seen among clinical parameters or tear proteins. Topical application of rebamipide suspension significantly increased F-WGA intensity, a marker of membrane-associated mucins in SCL wearers. Copyright © 2017 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  3. Diabetic retinopathy: Proteomic approaches to help the differential diagnosis and to understand the underlying molecular mechanisms.

    PubMed

    Csősz, Éva; Deák, Eszter; Kalló, Gergő; Csutak, Adrienne; Tőzsér, József

    2017-01-06

    Diabetic retinopathy is the most common diabetic eye disease and a leading cause of blindness among patients with diabetes. The appearance and the severity of the symptoms correlate with the duration of diabetes and poor blood glucose level management. Diabetic retinopathy is also categorized as a chronic low-level inflammatory disease; the high blood glucose level promotes the accumulation of the advanced glycation end products and leads to the stimulation of monocytes and macrophages. Examination of protein level alterations in tears using state-of the art proteomics techniques have identified several proteins as possible biomarkers for the different stages of the diabetic retinopathy. Some of the differentially expressed tear proteins have a role in the barrier function of tears linking the diabetic retinopathy with another eye complication of diabetes, namely the diabetic keratopathy resulting in impaired wound healing. Understanding the molecular events leading to the eye complications caused by hyperglycemia may help the identification of novel biomarkers as well as therapeutic targets in order to improve quality of life of diabetic patients. Diabetic retinopathy (DR), the leading cause of blindness among diabetic patients can develop without any serious symptoms therefore the early detection is crucial. Because of the increasing prevalence there is a high need for improved screening methods able to diagnose DR as soon as possible. The non-invasive collection and the relatively high protein concentration make the tear fluid a good source for biomarker discovery helping the early diagnosis. In this work we have reviewed the administration of advanced proteomics techniques used in tear biomarker studies and the identified biomarkers with potential to improve the already existing screening methods for DR detection. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Establishment of an appropriate animal model for lacritin studies: cloning and characterization of lacritin in monkey eyes.

    PubMed

    Nakajima, T; Walkup, R D; Tochigi, A; Shearer, T R; Azuma, M

    2007-11-01

    Lacritin is a mitogen of human salivary gland cells as well as a stimulator of human corneal epithelial cells. It is expected to be an important factor in maintaining the surrounding ocular surface. The monkey would be a relevant animal model in which to study the role of lacritin in ophthalmic physiology and pathology. However, to our knowledge, no cDNA cloning or functional analysis of monkey lacritin has been performed. Thus, the purposes of this study were: (1) to clone the monkey ortholog of lacritin; (2) to characterize lacritin in tears from several species; and (3) to determine the tissues where lacritin is produced and secreted. cDNA for lacritin from rhesus macaque contained 547 bp, with 411 bp in an open reading frame (ORF) encoding a protein of 137 amino acids. Monkey lacritin showed 89% amino acid homology with human lacritin; one amino acid was deleted in all three monkey strains. The predicted MW of mature lacritin was 12.2 kDa, and the isoelectric point was 4.99. Lacritin showed anomalous migration at approximately 21.0 kDa on SDS-PAGE, as confirmed by immunoblotting and amino acid sequencing. Similar to native lacritin in monkey tears, a 21 kDa band was also detected in human tears. In contrast, no lacritin was observed at a similar position on SDS-PAGE in rat, rabbit and dog tears. In the monkey, lacritin mRNA was expressed highly in the lacrimal gland, moderately in the conjunctiva and the meibomian gland, and weakly in corneal epithelium. In primates, lacritin was produced in the lacrimal gland and secreted into tear fluid. These results suggest that lacritin might be important for the maintenance of the ocular surface in higher animals, such as monkeys and humans.

  5. Eastern Mediterranean geothermal resources and subduction dynamics

    NASA Astrophysics Data System (ADS)

    Roche, Vincent; Sternai, Pietro; Guillou-Frottier, Laurent; Jolivet, Laurent; Gerya, Taras

    2017-04-01

    The Aegean-Anatolian retreating subduction and collision zones have been investigated through 3D numerical geodynamic models involving slab rollback/tearing/breakoff constrained by, for instance, seismic tomography or anisotropy and geochemical proxies. Here, we integrate these investigations by using the well documented geothermal anomalies geothermal anomalies. First, we use 3D high-resolution thermo-mechanical numerical models to quantify the potential contribution of the past Aegean-Anatolian subduction dynamics to such present-day measured thermal anomalies. Results suggest an efficient control of subduction-related asthenospheric return flow on the regional distribution of thermal anomalies. Our quantification shows that the slab-induced shear heating at the base of the crust could partly explain the high heat flow values above the slab tear (i.e. in the Menderes Massif, Western Turkey). Second, the associated thermal signature at the base of the continental crust is used as basal thermal boundary condition for 2D crustal-scale models dedicated to the understanding of heat transfer from the abnormally hot mantle to the shallow geothermal reservoir. These models couple heat transfer and fluid flow equations with appropriate fluid and rock physical properties. Results suggest that permeable low-angle normal faults (detachments) in the back-arc region can control the bulk of the heat transport and fluid circulation patterns. We suggest that detachments can drain crustal and/or mantellic fluids up to several kilometers depths. At the basin-scale, we show that the permeability of detachments may control the reservoirs location. Temperatures at the base of detachments may be subject to protracted increase (due to anomalously high basal heat flow) through time, thereby generating dome-shaped thermal structures. These structures, usually with 20km characteristic wavelength, may reach the Moho involving lateral rheological contrasts and possibly crustal-scale boudinage, thereby driving the formation of new crustal detachments.

  6. Application study of magnetic fluid seal in hydraulic turbine

    NASA Astrophysics Data System (ADS)

    Yu, Z. Y.; Zhang, W.

    2012-11-01

    The waterpower resources of our country are abundant, and the hydroelectric power is developed, but at present the main shaft sealing device of hydraulic turbine is easy to wear and tear and the leakage is great. The magnetic fluid seal has the advantages of no contact, no wear, self-healing, long life and so on. In this paper, the magnetic fluid seal would be used in the main shaft of hydraulic turbine, the sealing structure was built the model, meshed the geometry, applied loads and solved by using MULTIPHYSICS in ANSYS software, the influence of the various sealing structural parameters such as tooth width, height, slot width, sealing gap on the sealing property were analyzed, the magnetic fluid sealing device suitable for large-diameter shaft and sealing water was designed, the sealing problem of the hydraulic turbine main shaft was solved effectively which will bring huge economic benefits.

  7. Not All Lacrimal Epithelial Cells are Created Equal—Heterogeneity of the Rabbit Lacrimal Gland and Differential Secretion

    PubMed Central

    Ding, Chuanqing; Huang, Jianyan; MacVeigh-Aloni, Michelle; Lu, Michael

    2013-01-01

    Aims To test the hypotheses that some epithelial cells in the rabbit lacrimal gland (LG) are mucin-secreting cells that are also particularly rich in aquaporin 5 (AQP5) and sodium potassium ATPase β1 subunit (NKAβ1), LG-secreted mucins contribute to the total mucin pool in tear film, and that the rabbit LG is a heterogenic gland where proteins secreted in response to different agonists are varied. Materials and methods LGs were obtained from adult female rabbits and processed for paraffin sections for hematoxylin and eosin (HE) staining, periodic acid-Schiff (PAS), mucicarmine, and Alcian blue (pH 0.4, 1.0, and 2.5) for the detection of mucins. Serial sections were used for immunohistochemistry (IHC) and PAS. LG lysates and fluids were assayed by dot blot for detection of mucins, and by SDS-PAGE to detect differences in protein profiles of LG fluids stimulated by different agonists. Results HE staining demonstrated that the LG is a heterogeneous gland where most epithelial cells are serous, while all duct cells are mucous cells. Some acini and individual acinar cells within serous acini are also mucous or seromucous cells and these cells are particularly rich in AQP5 and NKAβ1. Dot blot assay showed the presence of mucins in the LG fluids. The protein profiles of LG fluids from pilocarpine, phenylephrine, and isoproterenol varied significantly, particularly in the mid range. Conclusions Our data indicated that the rabbit LG is a heterogeneous gland that is composed of both serous and mucin-secreting cells, and mucins produced by the LG contribute to the mucin pool in the tear film. The heterogeneity of the rabbit LG supports the notion of differential secretion, i.e. the volume and composition of the LG fluids vary depending on various circumstances in the ocular surface and the body’s needs. PMID:21999223

  8. Contact geometry at the undersurface of the acromion with and without a rotator cuff tear.

    PubMed

    Lee, S B; Itoi, E; O'Driscoll, S W; An, K N

    2001-04-01

    The purpose of this study was to investigate the difference in contact geometry at the undersurface of acromion in shoulders with and without a rotator cuff (RC) tear. Case-control study. Forty fresh cadaveric shoulders (average age at death, 61 years) without gross osteoarthritic changes were divided into the intact RC group (n = 20) and the RC tear group (n = 20). Clinical impingement was simulated by compressing the humeral head and the intact portion of the RC against the coracoacromial arch with an axial compressive force of 25 kg while the humerus was held abducted 20 degrees in the scapular plane. The contact pattern between the acromion and the RC was measured with Fuji Prescale super low-pressure-sensitive film (Fuji Photo Film Co, Ltd, Tokyo, Japan). The imprint image was analyzed using Global Lab image software (Automatix, Marlboro, MA). The percentage of the maximum anteroposterior dimension of the imprint on Fuji film to the anteroposterior diameter of the acromial undersurface was 29% +/- 9% in intact RC shoulders, and 39% +/- 13% in shoulders with an RC tear (P >.05). The percentage of the maximum mediolateral dimension of the imprint to the mediolateral diameter of the corresponding part of the acromial undersurface was 27% +/- 12% in intact RC shoulders, and 48% +/- 11% in shoulders with an RC tear. This difference was statistically significant (P <.005). The contact geometry of the acromial undersurface with the underlying RC in the anteroposterior dimension, which might be related to the appearance in supraspinatus outlet view, was not significantly different between shoulders with and without an RC tear. These findings suggest that factors other than acromial shape play a significant role in the pathogenesis of RC tears. The implication regarding the role of acromioplasty remains to be clarified.

  9. Explosive Magnetic Reconnection in Double-current Sheet Systems: Ideal versus Resistive Tearing Mode

    NASA Astrophysics Data System (ADS)

    Baty, Hubert

    2017-03-01

    Magnetic reconnection associated with the tearing instability occurring in double-current sheet systems is investigated within the framework of resistive magnetohydrodynamics (MHD) in a two-dimensional Cartesian geometry. A special emphasis on the existence of fast and explosive phases is taken. First, we extend the recent theory on the ideal tearing mode of a single-current sheet to a double-current layer configuration. A linear stability analysis shows that, in long and thin systems with (length to shear layer thickness) aspect ratios scaling as {S}L9/29 (S L being the Lundquist number based on the length scale L), tearing modes can develop on a fast Alfvénic timescale in the asymptotic limit {S}L\\to ∞ . The linear results are confirmed by means of compressible resistive MHD simulations at relatively high S L values (up to 3× {10}6) for different current sheet separations. Moreover, the nonlinear evolution of the ideal double tearing mode (IDTM) exhibits a richer dynamical behavior than its single-tearing counterpart, as a nonlinear explosive growth violently ends up with a disruption when the two current layers interact trough the merging of plasmoids. The final outcome of the system is a relaxation toward a new state, free of magnetic field reversal. The IDTM dynamics is also compared to the resistive double tearing mode dynamics, which develops in similar systems with smaller aspect ratios, ≳ 2π , and exhibits an explosive secondary reconnection, following an initial slow resistive growth phase. Finally, our results are used to discuss the flaring activity in astrophysical magnetically dominated plasmas, with a particular emphasis on pulsar systems.

  10. Nonlinear asymmetric tearing mode evolution in cylindrical geometry

    DOE PAGES

    Teng, Qian; Ferraro, N.; Gates, David A.; ...

    2016-10-27

    The growth of a tearing mode is described by reduced MHD equations. For a cylindrical equilibrium, tearing mode growth is governed by the modified Rutherford equation, i.e., the nonlinear Δ'(w). For a low beta plasma without external heating, Δ'(w) can be approximately described by two terms, Δ' ql(w), Δ'A(w). In this work, we present a simple method to calculate the quasilinear stability index Δ'ql rigorously, for poloidal mode number m ≥ 2. Δ' ql is derived by solving the outer equation through the Frobenius method. Δ'ql is composed of four terms proportional to: constant Δ' 0, w, wlnw, and w2.more » Δ' A is proportional to the asymmetry of island that is roughly proportional to w. The sum of Δ' ql and Δ' A is consistent with the more accurate expression calculated perturbatively. The reduced MHD equations are also solved numerically through a 3D MHD code M3D-C1. The analytical expression of the perturbed helical flux and the saturated island width agree with the simulation results. Lastly, it is also confirmed by the simulation that the Δ' A has to be considered in calculating island saturation.« less

  11. Velocity space resolved absolute measurement of fast ion losses induced by a tearing mode in the ASDEX Upgrade tokamak

    NASA Astrophysics Data System (ADS)

    Galdon-Quiroga, J.; Garcia-Munoz, M.; Sanchis-Sanchez, L.; Mantsinen, M.; Fietz, S.; Igochine, V.; Maraschek, M.; Rodriguez-Ramos, M.; Sieglin, B.; Snicker, A.; Tardini, G.; Vezinet, D.; Weiland, M.; Eriksson, L. G.; The ASDEX Upgrade Team; The EUROfusion MST1 Team

    2018-03-01

    Absolute flux of fast ion losses induced by tearing modes have been measured by means of fast ion loss detectors (FILD) for the first time in RF heated plasmas in the ASDEX Upgrade tokamak. Up to 30 MW m-2 of fast ion losses are measured by FILD at 5 cm from the separatrix, consistent with infra-red camera measurements, with energies in the range of 250-500 keV and pitch angles corresponding to large trapped orbits. A resonant interaction between the fast ions in the high energy tail of the ICRF distribution and a m/n  =  5/4 tearing mode leads to enhanced fast ion losses. Around 9.3 +/- 0.7 % of the fast ion losses are found to be coherent with the mode and scale linearly with its amplitude, indicating the convective nature of the transport mechanism. Simulations have been carried out to estimate the contribution of the prompt losses. A good agreement is found between the simulated and the measured velocity space of the losses. The velocity space resonances that may be responsible for the enhanced fast ion losses are identified.

  12. Hyaluronan receptors in the human ocular surface: a descriptive and comparative study of RHAMM and CD44 in tissues, cell lines and freshly collected samples.

    PubMed

    García-Posadas, Laura; Contreras-Ruiz, Laura; López-García, Antonio; Villarón Álvarez, Sonia; Maldonado, Miguel J; Diebold, Yolanda

    2012-02-01

    The purpose of this study was to demonstrate the presence of the receptor for hyaluronan-mediated motility (RHAMM) in human conjunctival epithelium and in two widely used cell lines from human corneal (HCE) and conjunctival (IOBA-NHC) epithelia. We compared the distribution of RHAMM proteins and mRNAs in human ocular surface tissues (corneal, limbal and conjunctival), HCE and IOBA-NHC cell lines, and corneal and conjunctival epithelia primary samples from healthy donors with the previously identified hyaluronan receptor CD44. We also aimed to determine if soluble CD44 (sCD44) was present in human tears, as it could have a role in the interaction of the tear fluid with hyaluronan. Protein expression was evaluated by Western blots and immunofluorescence microscopy. mRNA expression was evaluated by RT-PCR and Q-PCR. sCD44 was analyzed by ELISA in culture supernatants and in human tears. We describe the expression of RHAMM in human healthy conjunctiva and in HCE and IOBA-NHC cells at both protein and mRNA levels, and the presence of sCD44 in human tears. Furthermore, we detected CD44 and sCD44 expression variations in in vitro inflammatory conditions. This study also focused on the necessary caution with which the conclusions extracted from cell lines should be made, and in the great value of using primary samples as often as possible.

  13. Ocular allergy and dry eye syndrome.

    PubMed

    Bielory, Leonard

    2004-10-01

    Ocular allergy is a common clinical disorder that includes dry eye syndrome in its differential diagnosis. While ocular allergy treatments have continued to evolve since the early 1990s when the new prescription topical agents became available, there have been no major advances in the treatment of dry eye syndrome other than changes in the chemical structures of various artificial tear formulations. This review is timely and relevant due to the recent FDA approval of several new agents for the treatment of dry eye syndrome. The literature reviewed brings the practicing allergist/clinical immunologist up to date on the recent understanding that T-cell activation plays a key role in dry eye syndrome immunopathophysiology. In addition, the parallel novel treatment developments are discussed, including new formulations for tear substitutes, topical cyclosporine A and purinergic receptor (P2Y2) agonists. The recent developments bode well for patients who are referred for ocular allergy, including dry eye syndrome. A new formulation for a tear substitute that generates a 'soft gel' covering the ocular surface (in situ) is ideal for early forms of dry syndrome, while topical cyclosporine is the first new real prescription treatment for patients with moderate to severe forms of dry eye. Another potential agent to revolutionize the treatment of various disorders is based on the discovery of the purinergic receptor agonists. This is not only relevant for the production of mucin and the change in tear fluid content, but it may also have implications for other sinopulmonary disorders such as cystic fibrosis and chronic sinusitis.

  14. The biomechanical modelling of non-ballistic skin wounding: blunt-force injury.

    PubMed

    Whittle, Kelly; Kieser, Jules; Ichim, Ionut; Swain, Michael; Waddell, Neil; Livingstone, Vicki; Taylor, Michael

    2008-01-01

    Knowledge of the biomechanical dynamics of blunt force trauma is indispensable for forensic reconstruction of a wounding event. In this study, we describe and interpret wound features on a synthetic skin model under defined laboratory conditions. To simulate skin and the sub-dermal tissues we used open-celled polyurethane sponge (foam), covered by a silicone layer. A drop tube device with three tube lengths (300, 400, and 500 mm), each secured to a weighted steel scaffold and into which a round, 5-kg Federal dumbbell of length 180 mm and diameter 8 cm was placed delivered blows of known impact. To calculate energy and velocity at impact the experimental set-up was replicated using rigid-body dynamics and motion simulation software. We soaked each foam square in 500 mL water, until fully saturated, immediately before placing it beneath the drop tube. We then recorded and classified both external and internal lacerations. The association between external wounding rates and the explanatory variables sponge type, sponge thickness, and height were investigated using Poisson regression. Tears (lacerations) of the silicone skin layer resembled linear lacerations seen in the clinical literature and resulted from only 48.6% of impacts. Poisson regression showed there was no significant difference between the rate of external wounding for different sponge types (P = 0.294) or different drop heights (P = 0.276). Most impacts produced "internal wounds" or subsurface cavitation (96%). There were four internal "wound" types; Y-shape (53%), linear (25%), stellate (16%), and double crescent (6%). The two-way interaction height by sponge type was statistically significant in the analysis of variance model (P = 0.035). The other two-way interactions; height by thickness and sponge type by thickness, were also bordering on statistical significance (P = 0.061 and P = 0.071, respectively). The observation that external wounds were present for less than half of impacts only, but that nearly all impacts resulted in internal wounds, might explain the observed haematoma formation and contusions so often associated with blunt-force injuries. Our study also confirms the key role of hydrodynamic pressure changes in the actual tearing of subcutaneous tissue. At the moment and site of impact, transferred kinetic energy creates a region of high pressure on the fluid inside the tissue. As a result of the incompressibility of the fluid, this will be displaced away from the impact at a rate that depends on the velocity (or kinetic energy) of impact and the permeability and stiffness of the polymeric foam and skin layer.

  15. Generating Inviscid and Viscous Fluid Flow Simulations over a Surface Using a Quasi-simultaneous Technique

    NASA Technical Reports Server (NTRS)

    Sturdza, Peter (Inventor); Martins-Rivas, Herve (Inventor); Suzuki, Yoshifumi (Inventor)

    2014-01-01

    A fluid-flow simulation over a computer-generated surface is generated using a quasi-simultaneous technique. The simulation includes a fluid-flow mesh of inviscid and boundary-layer fluid cells. An initial fluid property for an inviscid fluid cell is determined using an inviscid fluid simulation that does not simulate fluid viscous effects. An initial boundary-layer fluid property a boundary-layer fluid cell is determined using the initial fluid property and a viscous fluid simulation that simulates fluid viscous effects. An updated boundary-layer fluid property is determined for the boundary-layer fluid cell using the initial fluid property, initial boundary-layer fluid property, and an interaction law. The interaction law approximates the inviscid fluid simulation using a matrix of aerodynamic influence coefficients computed using a two-dimensional surface panel technique and a fluid-property vector. An updated fluid property is determined for the inviscid fluid cell using the updated boundary-layer fluid property.

  16. Computational predictions of damage propagation preceding dissection of ascending thoracic aortic aneurysms.

    PubMed

    Mousavi, S Jamaleddin; Farzaneh, Solmaz; Avril, Stéphane

    2018-04-01

    Dissections of ascending thoracic aortic aneurysms (ATAAs) cause significant morbidity and mortality worldwide. They occur when a tear in the intima-media of the aorta permits the penetration of the blood and the subsequent delamination and separation of the wall in 2 layers, forming a false channel. To predict computationally the risk of tear formation, stress analyses should be performed layer-specifically and they should consider internal or residual stresses that exist in the tissue. In the present paper, we propose a novel layer-specific damage model based on the constrained mixture theory, which intrinsically takes into account these internal stresses and can predict appropriately the tear formation. The model is implemented in finite-element commercial software Abaqus coupled with user material subroutine. Its capability is tested by applying it to the simulation of different exemplary situations, going from in vitro bulge inflation experiments on aortic samples to in vivo overpressurizing of patient-specific ATAAs. The simulations reveal that damage correctly starts from the intimal layer (luminal side) and propagates across the media as a tear but never hits the adventitia. This scenario is typically the first stage of development of an acute dissection, which is predicted for pressures of about 2.5 times the diastolic pressure by the model after calibrating the parameters against experimental data performed on collected ATAA samples. Further validations on a larger cohort of patients should hopefully confirm the potential of the model in predicting patient-specific damage evolution and possible risk of dissection during aneurysm growth for clinical applications. Copyright © 2017 John Wiley & Sons, Ltd.

  17. Generating Inviscid and Viscous Fluid-Flow Simulations over an Aircraft Surface Using a Fluid-Flow Mesh

    NASA Technical Reports Server (NTRS)

    Rodriguez, David L. (Inventor); Sturdza, Peter (Inventor)

    2013-01-01

    Fluid-flow simulation over a computer-generated aircraft surface is generated using inviscid and viscous simulations. A fluid-flow mesh of fluid cells is obtained. At least one inviscid fluid property for the fluid cells is determined using an inviscid fluid simulation that does not simulate fluid viscous effects. A set of intersecting fluid cells that intersects the aircraft surface are identified. One surface mesh polygon of the surface mesh is identified for each intersecting fluid cell. A boundary-layer prediction point for each identified surface mesh polygon is determined. At least one boundary-layer fluid property for each boundary-layer prediction point is determined using the at least one inviscid fluid property of the corresponding intersecting fluid cell and a boundary-layer simulation that simulates fluid viscous effects. At least one updated fluid property for at least one fluid cell is determined using the at least one boundary-layer fluid property and the inviscid fluid simulation.

  18. Clinical and Molecular Inflammatory Response in Sjögren Syndrome-Associated Dry Eye Patients Under Desiccating Stress.

    PubMed

    López-Miguel, Alberto; Tesón, Marisa; Martín-Montañez, Vicente; Enríquez-de-Salamanca, Amalia; Stern, Michael E; González-García, María J; Calonge, Margarita

    2016-01-01

    To evaluate the response of the lacrimal function unit in Sjögren syndrome (SS)-associated dry eye patients exposed to 2 simulated daily life environmental conditions. Prospective crossover pilot study. Fourteen female SS dry eye patients were exposed for 2 hours to a controlled normal condition (23 C, 45% relative humidity, and air flow 0.10 m/s) and a controlled adverse condition that simulates desiccating stress (23 C, 5% relative humidity, and air flow 0.10 m/s). The following dry eye tests were performed before and after the exposure: tear osmolarity, phenol red thread test, conjunctival hyperemia, fluorescein tear break-up time, corneal fluorescein staining, conjunctival lissamine green staining, and Schirmer test. Levels of 16 molecules were analyzed in tears by multiplex immunobead analysis. Clinical evaluation showed lacrimal functional unit impairment after the desiccating stress: significantly increased tear osmolarity (315.7 ± 3.0 vs 327.7 ± 5.1 mOsm/L, P = .03), conjunctival hyperemia (1.3 ± 0.1 vs 1.6 ± 0.1, P = .05), and corneal staining in temporal (3.5 ± 0.5 vs 4.7 ± 0.4, P = .01) and nasal (3.6 ± 0.5 vs 4.5 ± 0.5, P = .04) areas. Tear concentrations increased for interleukin-1 receptor antagonist (16 557.1 ± 4047.8 vs 31 895.3 ± 5916.5 pg/mL, P = .01), interleukin-6 (63.8 ± 20.2 vs 111.5 ± 29.6 pg/mL, P = .02), interleukin-8 (2196.1 ± 737.9 vs 3753.2 ± 1106.0 pg/mL, P = .03), and matrix metalloproteinase-9 (101 515.6 ± 37 088.4 vs 145 867.1 ± 41 651.5 pg/mL, P = .03). After the simulated normal condition, only a significant increase in nasal corneal staining (2.9 ± 0.5 vs 3.6 ± 0.5, P = .03) was observed. Even a short exposure to a desiccating environment can produce a significant deterioration of the lacrimal function unit in female SS dry eye patients. The often unnoticed exposure to these conditions during daily life may increase inflammatory activity rapidly, triggering an ocular surface deterioration. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. The hip fluid seal--Part II: The effect of an acetabular labral tear, repair, resection, and reconstruction on hip stability to distraction.

    PubMed

    Nepple, Jeffrey J; Philippon, Marc J; Campbell, Kevin J; Dornan, Grant J; Jansson, Kyle S; LaPrade, Robert F; Wijdicks, Coen A

    2014-04-01

    The acetabular labrum is theorized to be important to normal hip function by providing stability to distraction forces through the suction effect of the hip fluid seal. The purpose of this study was to determine the relative contributions of the hip capsule and labrum to the distractive stability of the hip, and to characterize hip stability to distraction forces in six labral conditions: intact labrum, labral tear, labral repair (looped vs. through sutures), partial resection, labral reconstruction with iliotibial band, and complete resection. Eight cadaveric hips with a mean age of 47.8 years (SD 4.3, range 41-51 years) were included. For each condition, the hip seal was broken by distracting the hip at a rate of 0.33 mm/s while the required force, energy, and negative intra-articular pressure were measured. For comparisons between labral conditions, measurements were normalized to the intact labral state (percent of intact). The relative contribution of the labrum to distractive stability was greatest at 1 and 2 mm of displacement, where it was significantly greater than the role of the capsule and accounted for 77 % (SD 27 %, p = 0.006) and 70 % (SD 7 %, p = 0.009) of total distractive stability, respectively. The relative contribution of the capsule to distractive stability increased with progressive displacement, providing 41 % (SD 49 %) and 52 % (SD 53 %) of distractive stability at 3 and 5 mm of distraction, respectively. The maximal distraction force required to break the hip seal in the intact labral state (capsule removed) varied from 124 to 150 N. Labral tear, partial resection, and complete resection resulted in average maximal distraction forces of 76 % (SD 34 %), 29 % (SD 26 %), and 27 % (SD 22 %), respectively, compared to the intact state. Through type labral repairs resulted in significantly greater improvements (from the labral tear state) in maximal negative pressure generated, compared to looped type repairs (median increase; +32 vs. -9 %, p = 0.029). Labral reconstruction resulted in a mean maximal distraction force of 66 % (SD 35 %), with a significant improvement of 37 % compared to partial labral resection (p < 0.001). The acetabular labrum was the primary hip stabilizer to distraction forces at small displacements (1-2 mm). Partial labral resection significantly decreased the distractive strength of the hip fluid seal. Labral reconstruction significantly improved distractive stability, compared to partial labral resection. The results of this study may provide insight into the relative importance of the capsule and labrum to distractive stability of the hip and may help to explain hip microinstability in the setting of labral disease.

  20. Linear growth rates of resistive tearing modes with sub-Alfvénic streaming flow

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wu, L. N.; College of Sciences, China Jiliang University, Hangzhou 310018; Ma, Z. W., E-mail: zwma@zju.edu.cn

    2014-07-15

    The tearing instability with sub-Alfvénic streaming flow along the external magnetic field is investigated using resistive MHD simulation. It is found that the growth rate of the tearing mode instability is larger than that without the streaming flow. With the streaming flow, there exist two Alfvén resonance layers near the central current sheet. The larger perturbation of the magnetic field in two closer Alfvén resonance layers could lead to formation of the observed cone structure and can largely enhance the development of the tearing mode for a narrower streaming flow. For a broader streaming flow, a larger separation of Alfvénmore » resonance layers reduces the magnetic reconnection. The linear growth rate decreases with increase of the streaming flow thickness. The growth rate of the tearing instability also depends on the plasma beta (β). When the streaming flow is embedded in the current sheet, the growth rate increases with β if β < β{sub s}, but decreases if β > β{sub s}. The existence of the specific value β{sub s} can be attributed to competition between the suppressing effect of β and the enhancing effect of the streaming flow on the magnetic reconnection. The critical value β{sub s} increases with increase of the streaming flow strength.« less

  1. Modulation of Core Turbulent Density Fluctuations by Large-Scale Neoclassical Tearing Mode Islands in the DIII-D Tokamak

    DOE PAGES

    Bardóczi, L.; Rhodes, T. L.; Carter, T. A.; ...

    2016-05-26

    We report the first observation of localized modulation of turbulent density uctuations en (via Beam Emission Spectroscopy) by neoclassical tearing modes (NTMs) in the core of the DIII-D tokamak. NTMs are important as they often lead to severe degradation of plasma confinement and disruptions in high-confinement fusion experiments. Magnetic islands associated with NTMs significantly modify the profiles and turbulence drives. In this experiment n was found to be modulated by 14% across the island. Gyrokinetic simulations suggest that en could be dominantly driven by the ion temperature gradient (ITG) instability.

  2. The linear tearing instability in three dimensional, toroidal gyro-kinetic simulations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hornsby, W. A., E-mail: william.hornsby@ipp.mpg.de; Migliano, P.; Buchholz, R.

    2015-02-15

    Linear gyro-kinetic simulations of the classical tearing mode in three-dimensional toroidal geometry were performed using the global gyro-kinetic turbulence code, GKW. The results were benchmarked against a cylindrical ideal MHD and analytical theory calculations. The stability, growth rate, and frequency of the mode were investigated by varying the current profile, collisionality, and the pressure gradients. Both collisionless and semi-collisional tearing modes were found with a smooth transition between the two. A residual, finite, rotation frequency of the mode even in the absence of a pressure gradient is observed, which is attributed to toroidal finite Larmor-radius effects. When a pressure gradientmore » is present at low collisionality, the mode rotates at the expected electron diamagnetic frequency. However, the island rotation reverses direction at high collisionality. The growth rate is found to follow a η{sup 1∕7} scaling with collisional resistivity in the semi-collisional regime, closely following the semi-collisional scaling found by Fitzpatrick. The stability of the mode closely follows the stability analysis as performed by Hastie et al. using the same current and safety factor profiles but for cylindrical geometry, however, here a modification due to toroidal coupling and pressure effects is seen.« less

  3. Does high knee flexion cause separation of meniscal repairs?

    PubMed

    Lin, David L; Ruh, Sarah S; Jones, Hugh L; Karim, Azim; Noble, Philip C; McCulloch, Patrick C

    2013-09-01

    Previous clinical studies comparing nonrestrictive and restrictive protocols after meniscal repair have shown no difference in outcomes; however, some surgeons still limit range of motion out of concern that it will place undue stress on the repair. Large acute medial meniscal tears will gap during simulated open chain exercises at high flexion angles, and a repaired construct with vertical mattress sutures will not gap. Controlled laboratory study. Tantalum beads were implanted in the medial menisci of 6 fresh-frozen cadaveric knees via an open posteromedial approach. Each knee underwent 10 simulated open chain flexion cycles with loading of the quadriceps and hamstrings. Testing was performed on 3 different states of the meniscus: intact, torn, and repaired. Biplanar radiographs were taken of the loaded knee in 90°, 110°, and 135° of flexion for each state. A 2.5-cm tear was created in the posteromedial meniscus and repaired with inside-out vertical mattress sutures. Displacement of pairs of beads spanning the tear was measured in all planes by use of radiostereometric analysis (RSA) with an accuracy of better than 80 μm. With a longitudinal tear, compression rather than gapping occurred in all 3 regions of the posterior horn of the meniscus (mean ± standard deviation for medial collateral ligament [MCL], -321 ± 320 μm; midposterior, -487 ± 256 μm; root, -318 ± 150 μm) with knee flexion. After repair, meniscal displacement returned part way to intact values in both the MCL (+55 ± 250 μm) and root region (-170 ± 123 μm) but not the midposterior region, where further compression was seen (-661 ± 278 μm). Acute posteromedial meniscal tears and repairs with vertical mattress sutures do not gap, but rather compress in the transverse plane at higher flexion angles when subjected to physiologic loads consistent with active, open kinetic chain range of motion rehabilitation exercises. The kinematics of the repaired meniscus more closely resemble that of the intact meniscus than that of the torn meniscus in regions adjacent to the MCL and the root but not in the midposterior region, where meniscal repair led to increased compression across the tear plane. This study supports the idea that nonrestrictive unresisted open chain range of motion protocols do not place undue stress on meniscal repairs.

  4. Hyaluronic acid coated poly-epsilon-caprolactone nanospheres deliver high concentrations of cyclosporine A into the cornea.

    PubMed

    Yenice, Irem; Mocan, Mehmet C; Palaska, Erhan; Bochot, Amélie; Bilensoy, Erem; Vural, Imran; Irkeç, Murat; Hincal, A Atilla

    2008-09-01

    The objective of this study was to determine cyclosporine A (Cy A) levels in ocular tissues and fluids after topical administration of poly-epsilon-caprolactone (PCL)/benzalkonium chloride (BKC) nanospheres and hyaluronic acid (HA) coated PCL/BKC nanospheres onto healthy rabbit corneas. Nanospheres were prepared by nanoprecipitation and purified by gradient-rate centrifugation. Cy A (0.1%) in either castor oil solution (group 1), PCL/BKC nanosphere formulation (group 2) or HA coated PCL/BKC nanosphere formulation (group 3) was instilled onto rabbit corneas. Tear samples were adsorbed onto Schirmer tear strips. Cy A concentrations of fluid (blood, aqueous humor, tear) and specimen extracts (cornea, conjunctiva, iris/ciliary body) were determined by high performance liquid chromatography-mass spectrometry (LC-MS). The mean corneal Cy A concentration obtained at 0.5, 1, 2, 4, 8 and 24h following instillation of the formulations ranged between 0.12 and 1.2 ng/mg tissue for group 1, 5.9-15.5 ng/mg tissue for group 2 and 11.4-23.0 ng/mg for group 3 (one-way analysis of variance (ANOVA) and pairwise tests (SNK (Student-Newman-Keuls) and Tukey); p<0.05). Conjunctival Cy A levels of group 2 and 3 were not significantly different at any of the time points tested. However, there was a significant difference between Cy A concentration of castor oil formulation and that of PCL/BKC nanosphere formulation at 1 and 8h (p<0.05). The mean iris/ciliary body concentrations obtained with the three formulations were not significantly different at any time point with the exception of group 2 levels being higher than those of groups 1 and 3 at 1h (p<0.05). The lowest ocular tear Cy A concentrations (16-114 ng/ml) were found following the instillation of HA coated PCL/BKC nanoparticles (group 3) during the time period tested. Cy A loaded PCL/BKC and HA coated PCL/BKC nanospheres are able to achieve high levels of Cy A in the cornea that is 10-15-fold higher than that is achieved with Cy A solution in castor oil. Nanosphere formulation and HA may play an important role in delivering high levels of cyclosporine A into the cornea.

  5. Integrated simulations of saturated neoclassical tearing modes in DIII-D, Joint European Torus, and ITER plasmas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Halpern, Federico D.; Bateman, Glenn; Kritz, Arnold H.

    2006-06-15

    A revised version of the ISLAND module [C. N. Nguyen et al., Phys. Plasmas 11, 3604 (2004)] is used in the BALDUR code [C. E. Singer et al., Comput. Phys. Commun. 49, 275 (1988)] to carry out integrated modeling simulations of DIII-D [J. Luxon, Nucl. Fusion 42, 614 (2002)], Joint European Torus (JET) [P. H. Rebut et al., Nucl. Fusion 25, 1011 (1985)], and ITER [R. Aymar et al., Plasma Phys. Control. Fusion 44, 519 (2002)] tokamak discharges in order to investigate the adverse effects of multiple saturated magnetic islands driven by neoclassical tearing modes (NTMs). Simulations are carried outmore » with a predictive model for the temperature and density pedestal at the edge of the high confinement mode (H-mode) plasma and with core transport described using the Multi-Mode model. The ISLAND module, which is used to compute magnetic island widths, includes the effects of an arbitrary aspect ratio and plasma cross sectional shape, the effect of the neoclassical bootstrap current, and the effect of the distortion in the shape of each magnetic island caused by the radial variation of the perturbed magnetic field. Radial transport is enhanced across the width of each magnetic island within the BALDUR integrated modeling simulations in order to produce a self-consistent local flattening of the plasma profiles. It is found that the main consequence of the NTM magnetic islands is a decrease in the central plasma temperature and total energy. For the DIII-D and JET discharges, it is found that inclusion of the NTMs typically results in a decrease in total energy of the order of 15%. In simulations of ITER, it is found that the saturated magnetic island widths normalized by the plasma minor radius, for the lowest order individual tearing modes, are approximately 24% for the 2/1 mode and 12% for the 3/2 mode. As a result, the ratio of ITER fusion power to heating power (fusion Q) is reduced from Q=10.6 in simulations with no NTM islands to Q=2.6 in simulations with fully saturated NTM islands.« less

  6. A novel generation of 3D SAR-based passive micromixer: efficient mixing and low pressure drop at a low Reynolds number

    NASA Astrophysics Data System (ADS)

    Viktorov, Vladimir; Nimafar, Mohammad

    2013-05-01

    This study introduces a novel generation of 3D splitting and recombination (SAR) passive micromixer with microstructures placed on the top and bottom floors of microchannels called a ‘chain mixer’. Both experimental verification and numerical analysis of the flow structure of this type of passive micromixer have been performed to evaluate the mixing performance and pressure drop of the microchannel, respectively. We propose here two types of chain mixer—chain 1 and chain 2—and compare their mixing performance and pressure drop with other micromixers, T-, o- and tear-drop micromixers. Experimental tests carried out in the laminar flow regime with a low Reynolds number range, 0.083 ≤ Re ≤ 4.166, and image-based techniques are used to evaluate the mixing efficiency. Also, the computational fluid dynamics code, ANSYS FLUENT-13.0 has been used to analyze the flow and pressure drop in the microchannel. Experimental results show that the chain and tear-drop mixer's efficiency is very high because of the SAR process: specifically, an efficiency of up to 98% can be achieved at the tested Reynolds number. The results also show that chain mixers have a lower required pressure drop in comparison with a tear-drop micromixer.

  7. Biomechanical characterization of a low density silicone elastomer filled with hollow microspheres for maxillofacial prostheses.

    PubMed

    Liu, Q; Shao, L Q; Xiang, H F; Zhen, D; Zhao, N; Yang, S G; Zhang, X L; Xu, J

    2013-01-01

    An ideal material for maxillofacial prostheses has not been found. We created a novel material: silicone elastomer filled with hollow microspheres and characterized its biomechanical properties. Expancel hollow microspheres were mixed with MDX4-4210 silicone elastomer using Q7-9180 silicone fluid as diluent. The volume fractions of microspheres were 0, 5, 15, and 30% v/v (volume ratio to the total volume of MDX4-4210 and microspheres). The microspheres dispersed well in the matrix. The physical properties and biocompatibility of the composites were examined. Shock absorption was the greatest by the 5% v/v composite, and decreased with increasing concentrations of microspheres. The density, thermal conductivity, Shore A hardness, tear and tensile strength decreased with increasing concentrations of microspheres, while elongation at break increased. Importantly, the tear strength of all composites was markedly lower than that of pure silicone elastomer. Cell viability assays indicated that the composite was of good biocompatibility. The composite with a volume fraction of 5% exhibited the optimal properties for use as a maxillofacial prosthesis, though its tear strength was markedly lower than that of silicone elastomer. In conclusion, we developed a novel light and soft material with good flexibility and biocompatibility, which holds a promising prospect for clinical application as maxillofacial prosthesis.

  8. Resistive MHD Simulation of Quasi-Single-Helicity State on KTX

    NASA Astrophysics Data System (ADS)

    Luo, Bing; Zhu, Ping; Li, Hong; Liu, Wandong

    2016-10-01

    The potential formation of quasi-single-helicity (QSH) state on Keda Torus eXperiment (KTX) is evaluated in resistive MHD simulations using the NIMROD code. In this work, we focus on the effects of finite resistivity on the mode structure and characteristics of the dominant linear and nonlinear resistive tearing-mode instability in a finite β, cylindrical reversed field pinch model configuration for KTX. In the typical resistivity regimes of KTX where Lundquist number S =105 , the plasma reaches a steady QSH state after the initial transient phase of multiple helicities. The dominat mode of the QSH state is developed from the dominat linear tearing mode instability. The conditions for and the variations of the formation of QSH states in different resistivity regimes of KTX will be reported and discussed. Supported by National Magnetic Confinement Fusion Science Program of China Grant Nos. 2014GB124002, 2015GB101004, 2011GB106000, and 2011GB106003.

  9. Thermomechanical coupling and dynamic strain ageing in ductile fracture

    NASA Astrophysics Data System (ADS)

    Delafosse, David

    1995-01-01

    This work is concerned with plastic deformation at the tip of a ductile tearing crack during propagation. Two kinds of effects are investigated: the thermomechanical coupling at the tip of a mobile ductile crack, and the influence of Dynamic Strain Aging (DSA) on ductile fracture. Three alloys are studied: a nickel based superalloy (N18), a soft carbon steel, and an Al-Li light alloy (2091). The experimental study of the thermo mechanical coupling effects by means of infrared thermography stresses the importance of plastic dissipation in the energy balance of ductile fracture. Numerical simulations involving plastic deformation as the only dissipation mechanism account for the main part of the measured heating. The effects of DSA on ductile tearing are investigated in the 2091 Al-Li alloy. Based on the strain rate/temperature dependence predicted by the standard model of DSA, an experimental procedure is set up for this purpose. Three main effects are evidenced. A maximum in tearing resistance is shown to be associated with the minimum of strain rate sensitivity. Through a simple model, this peak in tearing resistance is attributed to an increase in plastic dissipation as the strain rate sensitivity is decreased. Heterogenous plastic deformation is observed in the crack tip plastic zone. Comparison with uniaxial testing allows us to identify the observed strain heterogeneities as Portevin-Le Chatelier instabilities in the crack tip plastic zone. We perform a simplified numerical analysis of the effect of strain localization on crack tip screening. Finally, small crack propagation instabilities appear at temperatures slightly above that of the tearing resistance peak. These are interpreted as resulting from a positive feed-back between the local heating at the tip of a moving crack and the decrease in tearing resistance with increasing temperature.

  10. Effects of Prosthetic Mismatch and Subscapularis Tear on Glenohumeral Contact Patterns in Total Shoulder Arthroplasty: A Numerical Musculoskeletal Analysis.

    PubMed

    Sins, Lauranne; Tétreault, Patrice; Nuño, Natalia; Hagemeister, Nicola

    2016-12-01

    Prosthetic components' mismatch and subscapularis (SC) tear are determining factors for glenoid failure complication in nonconforming total shoulder arthroplasty (NC-TSA). Risk factors are linked to glenoid prosthetic loading. However, the mechanisms underlying the clinical observations remain unclear. This study assessed the combined impact of mismatch and subscapularis tear on glenoid loading. It was assumed that adequate glenoid loading was associated with minimal, but non-null, humeral head translations and contact pressure, as well as with maximal glenoid contact area, and that the center of pressure (COP) on the glenoid would have a centered displacement pattern. A numerical model was used to achieve two objectives. The first was to verify whether an optimum mismatch existed, for which failure risk would be minimal. The second was to explore the effect of subscapularis tear on the position of applied forces on the glenoid. A shoulder AnyBody musculoskeletal model was adapted to the arthroplasty context by introducing humeral head translations and contact between implants. Ten simulations were computed to compare combinations of varying mismatches (1.4 mm, 3.4 mm, 6.4 mm, 8.6 mm, and 9 mm) with two shoulder conditions (intact-muscle or subscapularis tear). Humeral head translations, center-of-pressure, contact area, contact pressure, and glenohumeral joint contact forces were numerically estimated. Mismatches between 3.4 mm and 6.4 mm were associated with the most minimal humeral translations and contact pressure, as well as with maximal contact area. Center of pressure displacement pattern differed according to shoulder condition, with an outward anterior tendency in presence of tear.

  11. The science of rotator cuff tears: translating animal models to clinical recommendations using simulation analysis.

    PubMed

    Mannava, Sandeep; Plate, Johannes F; Tuohy, Christopher J; Seyler, Thorsten M; Whitlock, Patrick W; Curl, Walton W; Smith, Thomas L; Saul, Katherine R

    2013-07-01

    The purpose of this article is to review basic science studies using various animal models for rotator cuff research and to describe structural, biomechanical, and functional changes to muscle following rotator cuff tears. The use of computational simulations to translate the findings from animal models to human scale is further detailed. A comprehensive review was performed of the basic science literature describing the use of animal models and simulation analysis to examine muscle function following rotator cuff injury and repair in the ageing population. The findings from various studies of rotator cuff pathology emphasize the importance of preventing permanent muscular changes with detrimental results. In vivo muscle function, electromyography, and passive muscle-tendon unit properties were studied before and after supraspinatus tenotomy in a rodent rotator cuff injury model (acute vs chronic). Then, a series of simulation experiments were conducted using a validated computational human musculoskeletal shoulder model to assess both passive and active tension of rotator cuff repairs based on surgical positioning. Outcomes of rotator cuff repair may be improved by earlier surgical intervention, with lower surgical repair tensions and fewer electromyographic neuromuscular changes. An integrated approach of animal experiments, computer simulation analyses, and clinical studies may allow us to gain a fundamental understanding of the underlying pathology and interpret the results for clinical translation.

  12. On the hot cracking susceptibility of a semisolid aluminium 6061 weld: Application of a coupled solidification- thermomechanical model

    NASA Astrophysics Data System (ADS)

    Zareie Rajani, H. R.; Phillion, A. B.

    2015-06-01

    A coupled solidification-thermomechanical model is presented that investigates the hot tearing susceptibility of an aluminium 6061 semisolid weld. Two key phenomena are considered: excessive deformation of the semisolid weld, initiating a hot tear, and the ability of the semisolid weld to heal the hot tear by circulation of the molten metal. The model consists of two major modules: weld solidification and thermomechanical analysis. 1) By means of a multi-scale model of solidification, the microstructural evolution of the semisolid weld is simulated in 3D. The semisolid structure, which varies as a function of welding parameters, is composed of solidifying grains and a network of micro liquid channels. The weld solidification module is utilized to obtain the solidification shrinkage. The size of the micro liquid channels is used as an indicator to assess the healing ability of the semisolid weld. 2) Using the finite element method, the mechanical interaction between the weld pool and the base metal is simulated to capture the transient force field deforming the semisolid weld. Thermomechanical stresses and shrinkage stresses are both considered in the analysis; the solidification contractions are extracted from the weld solidification module and applied to the deformation simulation as boundary conditions. Such an analysis enables characterization of the potential for excessive deformation of the weld. The outputs of the model are used to study the effect of welding parameters including welding current and speed, and also welding constraint on the hot cracking susceptibility of an aluminium alloy 6061 semisolid weld.

  13. Ethylene/acrylic elastomers (EAE): sealing application candidates for the automotive industry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carr, J.; Ginn, A.

    1979-01-01

    EAE, based on experimental elastomers developed by Du Pont and called ''Vamac'' (formerly ''MPE''), are ethylene/methyl acrylate copolymers compounded with appropriate plasticizers, fillers, and other additives. They function satisfactorily at -54/sup 0/ to +177/sup 0/C and have excellent tensile strength, elongation, and resistance to compression set, corrosion, tear, and weathering. They show good resistance to automatic transmission fluids, engine oil, some gear lubricants and hydrocarbon greases, water, engine coolants, and dilute acids and bases, but should not be used with gasoline, concentrated acids, high-pressure steam, automotive brake fluids, phosphate ester-based hydraulic fluids, diester-based synthetic lubricants, or chlorinated hydrocarbons. They needmore » no solid-lubricant or antiwear additives, but special mold-release preparations are necessary. They should be useful as seals for the transmission front pump, the clutch, and the engine front crankshaft and possibly for other sealing and nonseal applications (e.g., spark-plug boots).« less

  14. Self-folding mechanics of graphene tearing and peeling from a substrate

    NASA Astrophysics Data System (ADS)

    He, Ze-Zhou; Zhu, Yin-Bo; Wu, Heng-An

    2018-06-01

    Understanding the underlying mechanism in the tearing and peeling processes of graphene is crucial for the further hierarchical design of origami-like folding and kirigami-like cutting of graphene. However, the complex effects among bending moduli, adhesion, interlayer interaction, and local crystal structure during origami-like folding and kirigami-like cutting remain unclear, resulting in challenges to the practical applications of existing theoretical and experimental findings as well as to potential manipulations of graphene in metamaterials and nanodevices. Toward this end, classical molecular dynamics (MD) simulations are performed with synergetic theoretical analysis to explore the tearing and peeling of self-folded graphene from a substrate driven by external force and by thermal activation. It is found that the elastic energy localized at the small folding ridge plays a significant role in the crack trajectory. Due to the extremely small bending modulus of monolayer graphene, its taper angle when pulled by an external force follows a scaling law distinct from that in case of bilayer graphene. With the increase in the initial width of the folding ridge, the self-folded graphene, motivated by thermal fluctuations, can be self-assembled by spontaneous self-tearing and peeling from a substrate. Simultaneously, the scaling law between the taper angle and adhesive energy is independent of the motivations for thermal activation-induced self-assembly and external force tearing, providing effective insights into the underlying physics for graphene-based origami-like folding and kirigami-like cutting.

  15. Neoclassical tearing mode seeding by coupling with infernal modes in low-shear tokamaks

    NASA Astrophysics Data System (ADS)

    Kleiner, A.; Graves, J. P.; Brunetti, D.; Cooper, W. A.; Halpern, F. D.; Luciani, J.-F.; Lütjens, H.

    2016-09-01

    A numerical and an analytical study of the triggering of resistive MHD modes in tokamak plasmas with low magnetic shear core is presented. Flat q profiles give rise to fast growing pressure driven MHD modes, such as infernal modes. It has been shown that infernal modes drive fast growing islands on neighbouring rational surfaces. Numerical simulations of such instabilities in a MAST-like configuration are performed with the initial value stability code XTOR-2F in the resistive frame. The evolution of magnetic islands are computed from XTOR-2F simulations and an analytical model is developed based on Rutherford’s theory in combination with a model of resistive infernal modes. The parameter {{Δ }\\prime} is extended from the linear phase to the non-linear phase. Additionally, the destabilising contribution due to a helically perturbed bootstrap current is considered. Comparing the numerical XTOR-2F simulations to the model, we find that coupling has a strong destabilising effect on (neoclassical) tearing modes and is able to seed 2/1 magnetic islands in situations when the standard NTM theory predicts stability.

  16. Apar-T: code, validation, and physical interpretation of particle-in-cell results

    NASA Astrophysics Data System (ADS)

    Melzani, Mickaël; Winisdoerffer, Christophe; Walder, Rolf; Folini, Doris; Favre, Jean M.; Krastanov, Stefan; Messmer, Peter

    2013-10-01

    We present the parallel particle-in-cell (PIC) code Apar-T and, more importantly, address the fundamental question of the relations between the PIC model, the Vlasov-Maxwell theory, and real plasmas. First, we present four validation tests: spectra from simulations of thermal plasmas, linear growth rates of the relativistic tearing instability and of the filamentation instability, and nonlinear filamentation merging phase. For the filamentation instability we show that the effective growth rates measured on the total energy can differ by more than 50% from the linear cold predictions and from the fastest modes of the simulation. We link these discrepancies to the superparticle number per cell and to the level of field fluctuations. Second, we detail a new method for initial loading of Maxwell-Jüttner particle distributions with relativistic bulk velocity and relativistic temperature, and explain why the traditional method with individual particle boosting fails. The formulation of the relativistic Harris equilibrium is generalized to arbitrary temperature and mass ratios. Both are required for the tearing instability setup. Third, we turn to the key point of this paper and scrutinize the question of what description of (weakly coupled) physical plasmas is obtained by PIC models. These models rely on two building blocks: coarse-graining, i.e., grouping of the order of p ~ 1010 real particles into a single computer superparticle, and field storage on a grid with its subsequent finite superparticle size. We introduce the notion of coarse-graining dependent quantities, i.e., quantities depending on p. They derive from the PIC plasma parameter ΛPIC, which we show to behave as ΛPIC ∝ 1/p. We explore two important implications. One is that PIC collision- and fluctuation-induced thermalization times are expected to scale with the number of superparticles per grid cell, and thus to be a factor p ~ 1010 smaller than in real plasmas, a fact that we confirm with simulations. The other is that the level of electric field fluctuations scales as 1/ΛPIC ∝ p. We provide a corresponding exact expression, taking into account the finite superparticle size. We confirm both expectations with simulations. Fourth, we compare the Vlasov-Maxwell theory, often used for code benchmarking, to the PIC model. The former describes a phase-space fluid with Λ = + ∞ and no correlations, while the PIC plasma features a small Λ and a high level of correlations when compared to a real plasma. These differences have to be kept in mind when interpreting and validating PIC results against the Vlasov-Maxwell theory and when modeling real physical plasmas.

  17. Non-invasive estimation of hydration status changes through tear fluid osmolarity during exercise and post-exercise rehydration.

    PubMed

    Ungaro, Corey T; Reimel, Adam J; Nuccio, Ryan P; Barnes, Kelly A; Pahnke, Matthew D; Baker, Lindsay B

    2015-05-01

    To determine if tear fluid osmolarity (Tosm) can track changes in hydration status during exercise and post-exercise rehydration. Nineteen male athletes (18-37 years, 74.6 ± 7.9 kg) completed two randomized, counterbalanced trials; cycling (~95 min) with water intake to replace fluid losses or water restriction to progressively dehydrate to 3 % body mass loss (BML). After exercise, subjects drank water to maintain body mass (water intake trials) or progressively rehydrate to pre-exercise body mass (water restriction trials) over a 90-min recovery period. Plasma osmolality (Posm) and Tosm measurements (mean of right and left eyes) were taken pre-exercise, during rest periods between exercise bouts corresponding to 1, 2, and 3 % BML, and rehydration at 2, 1, and 0 % BML. During exercise mean (± SD) Tosm was significantly higher in water restriction vs. water intake trials at 1 % BML (299 ± 9 vs. 293 ± 9 mmol/L), 2 % BML (301 ± 9 vs. 294 ± 9 mmol/L), and 3 % BML (302 ± 9 vs. 292 ± 8 mmol/L). Mean Tosm progressively decreased during post-exercise rehydration and was not different between trials at 1 % BML (291 ± 8 vs. 290 ± 7 mmol/L) and 0 % BML (288 ± 7 vs. 289 ± 8 mmol/L). Mean Tosm tracked changes in hydration status similar to that of mean Posm; however, the individual responses in Tosm to water restriction and water intake was considerably more variable than that of Posm. Tosm is a valid indicator of changes in hydration status when looking at the group mean; however, large differences among subjects in the Tosm response to hydration changes limit its validity for individual recommendations.

  18. A mathematical model of the structure and evolution of small scale discrete auroral arcs

    NASA Technical Reports Server (NTRS)

    Seyler, C. E.

    1990-01-01

    A three dimensional fluid model which includes the dispersive effect of electron inertia is used to study the nonlinear macroscopic plasma dynamics of small scale discrete auroral arcs within the auroral acceleration zone and ionosphere. The motion of the Alfven wave source relative to the magnetospheric and ionospheric plasma forms an oblique Alfven wave which is reflected from the topside ionosphere by the negative density gradient. The superposition of the incident and reflected wave can be described by a steady state analytical solution of the model equations with the appropriate boundary conditions. This two dimensional discrete auroral arc equilibrium provides a simple explanation of auroral acceleration associated with the parallel electric field. Three dimensional fully nonlinear numerical simulations indicate that the equilibrium arc configuration evolves three dimensionally through collisionless tearing and reconnection of the current layer. The interaction of the perturbed flow and the transverse magnetic field produces complex transverse structure that may be the origin of the folds and curls observed to be associated with small scale discrete arcs.

  19. Dacron graft as replacement to dissected aorta: A three-dimensional fluid-structure-interaction analysis.

    PubMed

    Jayendiran, R; Nour, B M; Ruimi, A

    2018-02-01

    Aortic dissection (AD) is a serious medical condition characterized by a tear in the intima, the inner layer of the aortic walls. In such occurrence, blood is being diverted to the media (middle) layer and may result in patient death if not quickly attended. In the case where the diseased portion of the aorta needs to be replaced, one common surgical technique is to use a graft made of Dacron, a synthetic fabric. We investigate the response of a composite human aortic segment-Dacron graft structure subjected to blood flow using the three-dimensional fluid-structure-interaction (FSI) capability in Abaqus. We obtain stress and strain profiles in each of the three layers of the aortic walls as well as in the Dacron graft. Results are compared when elastic and hyperelastic models are used and when isotropy vs. anisotropy is assumed. The more complex case (hyperelastic-anisotropy) is represented by the Holzapfel-Gasser-Ogden (HGO) model which also accounts for the orientation of the fibers present in the tissues. The fluid flow is taken as Newtonian, incompressible, pulsatile and turbulent. The simulation show that for all the cases, the von Mises stress distribution at aorta-Dacron interface is well below the ultimate strength of the aorta. No significant change in radial displacement at the interface of the two materials due to blood flow is observed. Computation cost is also addressed and results show that the hyperelastic-anisotropic model takes about three times longer to run than the elastic isotropic case. Trade-off between accuracy and computational cost has to be weighted. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Fluid, solid and fluid-structure interaction simulations on patient-based abdominal aortic aneurysm models.

    PubMed

    Kelly, Sinead; O'Rourke, Malachy

    2012-04-01

    This article describes the use of fluid, solid and fluid-structure interaction simulations on three patient-based abdominal aortic aneurysm geometries. All simulations were carried out using OpenFOAM, which uses the finite volume method to solve both fluid and solid equations. Initially a fluid-only simulation was carried out on a single patient-based geometry and results from this simulation were compared with experimental results. There was good qualitative and quantitative agreement between the experimental and numerical results, suggesting that OpenFOAM is capable of predicting the main features of unsteady flow through a complex patient-based abdominal aortic aneurysm geometry. The intraluminal thrombus and arterial wall were then included, and solid stress and fluid-structure interaction simulations were performed on this, and two other patient-based abdominal aortic aneurysm geometries. It was found that the solid stress simulations resulted in an under-estimation of the maximum stress by up to 5.9% when compared with the fluid-structure interaction simulations. In the fluid-structure interaction simulations, flow induced pressure within the aneurysm was found to be up to 4.8% higher than the value of peak systolic pressure imposed in the solid stress simulations, which is likely to be the cause of the variation in the stress results. In comparing the results from the initial fluid-only simulation with results from the fluid-structure interaction simulation on the same patient, it was found that wall shear stress values varied by up to 35% between the two simulation methods. It was concluded that solid stress simulations are adequate to predict the maximum stress in an aneurysm wall, while fluid-structure interaction simulations should be performed if accurate prediction of the fluid wall shear stress is necessary. Therefore, the decision to perform fluid-structure interaction simulations should be based on the particular variables of interest in a given study.

  1. Prediction of Hot Tearing Using a Dimensionless Niyama Criterion

    NASA Astrophysics Data System (ADS)

    Monroe, Charles; Beckermann, Christoph

    2014-08-01

    The dimensionless form of the well-known Niyama criterion is extended to include the effect of applied strain. Under applied tensile strain, the pressure drop in the mushy zone is enhanced and pores grow beyond typical shrinkage porosity without deformation. This porosity growth can be expected to align perpendicular to the applied strain and to contribute to hot tearing. A model to capture this coupled effect of solidification shrinkage and applied strain on the mushy zone is derived. The dimensionless Niyama criterion can be used to determine the critical liquid fraction value below which porosity forms. This critical value is a function of alloy properties, solidification conditions, and strain rate. Once a dimensionless Niyama criterion value is obtained from thermal and mechanical simulation results, the corresponding shrinkage and deformation pore volume fractions can be calculated. The novelty of the proposed method lies in using the critical liquid fraction at the critical pressure drop within the mushy zone to determine the onset of hot tearing. The magnitude of pore growth due to shrinkage and deformation is plotted as a function of the dimensionless Niyama criterion for an Al-Cu alloy as an example. Furthermore, a typical hot tear "lambda"-shaped curve showing deformation pore volume as a function of alloy content is produced for two Niyama criterion values.

  2. Biomechanical comparison of single-row, double-row, and transosseous-equivalent repair techniques after healing in an animal rotator cuff tear model.

    PubMed

    Quigley, Ryan J; Gupta, Akash; Oh, Joo-Han; Chung, Kyung-Chil; McGarry, Michelle H; Gupta, Ranjan; Tibone, James E; Lee, Thay Q

    2013-08-01

    The transosseous-equivalent (TOE) rotator cuff repair technique increases failure loads and contact pressure and area between tendon and bone compared to single-row (SR) and double-row (DR) repairs, but no study has investigated if this translates into improved healing in vivo. We hypothesized that a TOE repair in a rabbit chronic rotator cuff tear model would demonstrate a better biomechanical profile than SR and DR repairs after 12 weeks of healing. A two-stage surgical procedure was performed on 21 New Zealand White Rabbits. The right subscapularis tendon was transected and allowed to retract for 6 weeks to simulate a chronic tear. Repair was done with the SR, DR, or TOE technique and allowed to heal for 12 weeks. Cyclic loading and load to failure biomechanical testing was then performed. The TOE repair showed greater biomechanical characteristics than DR, which in turn were greater than SR. These included yield load (p < 0.05), energy absorbed to yield (p < 0.05), and ultimate load (p < 0.05). For repair of a chronic, retracted rotator cuff tear, the TOE technique was the strongest biomechanical construct after healing followed by DR with SR being the weakest. Copyright © 2013 Orthopaedic Research Society.

  3. The effects of differential flow between rational surfaces on toroidal resistive MHD modes

    NASA Astrophysics Data System (ADS)

    Brennan, Dylan; Halfmoon, Michael; Rhodes, Dov; Cole, Andrew; Okabayashi, Michio; Paz-Soldan, Carlos; Finn, John

    2016-10-01

    Differential flow between resonant surfaces can strongly affect the coupling and penetration of resonant components of resistive modes, and yet this mechanism is not yet fully understood. This study focuses on the evolution of tearing instabilities and the penetration of imposed resonant magnetic perturbations (RMPs) in tokamak configurations relevant to DIII-D and ITER, including equilibrium flow shear. It has been observed on DIII-D that the onset of tearing instabilities leading to disruption is often coincident with a loss of differential rotation between a higher m/n tearing surface (normally the 4/3 or 3/2) and a lower m/n tearing surface (normally the 2/1). Imposing RMPs can strongly affect this coupling and the torques between the modes. We apply the nonlinear 3-D resistive magnetohydrodynamic (MHD) code NIMROD to study the mechanisms by which these couplings occur. Reduced MHD analyses are applied to study the effects of differential flow between resonant surfaces in the simulations. Interaction between resonant modes can cause significant energy transfer between them, effectively stabilizing one mode while the other grows. The flow mitigates this transfer, but also affects the individual modes. The combination of these effects determines the nonlinear outcome. Supported by US DOE Grants DE-SC0014005 and DE-SC0014119.

  4. The Effects of Posterior Rotator Cuff Cable Tears on Glenohumeral Biomechanics in a Cadaveric Model of the Throwing Shoulder

    PubMed Central

    Photopoulos, Christos Demetris; ElAttrache, Neal S.; Doermann, Alex; Akeda, Masaki; McGarry, Michelle H.; Lee, Thay Q.

    2017-01-01

    Objectives: The rotator cuff cable has been postulated to be the primary load bearing substructure of the superior part of the rotator cuff. Tears of the posterior rotator cable are frequently seen in overhead throwing athletes. Although the biomechanical significance of the anterior rotator cable has been well described, our current understanding of the relevance of the posterior cable is limited. The purpose of this study was to examine how partial-thickness tears and full-thickness tears of the posterior rotator cable would alter glenohumeral biomechanics and kinematics in cadaveric shoulder models. Methods: Eight fresh-frozen cadaveric shoulder specimens were prepared and tested. To simulate the sequence of glenohumeral positions during the throwing motion, specimens were mounted on a custom shoulder testing system with the humerus positioned at 90° of abduction (30° scapular upward rotation, 60° glenohumeral abduction) and tested at 30, 60, 90, and 120 degrees of external rotation. After a circumferential capsulotomy was performed, rotator cuff muscles were loaded based on physiologic cross-sectional area ratios, and testing for each specimen was performed on each the following three conditions: intact posterior cable, partial-thickness (50%) articular-sided posterior cable tear, and full-thickness posterior cable tear. Primary outcome measures tested for each condition under the various degrees of glenohumeral rotation were: 1) anterior and total glenohumeral translation after application of a 30N anterior force; 2) path of glenohumeral articulation; 3) glenohumeral joint force. Results: With a 30N anterior force at 120° of external rotation, there was a significant increase in anterior glenohumeral translation between intact and full-thickness tear specimens (7.28±2.00mm and 17.49±3.75mm, respectively; p<0.05). Similarly, total joint translation at 120° of external rotation significantly increased between intact and full-thickness tear specimens (10.37±3.18mm and 23.37±5.05mm, respectively; p<0.05). No significant differences were apparent at other degrees of rotation (30, 60, 90 degrees), or with partial-thickness tears. Changes in the path of glenohumeral articulation were likewise most evident at 120° of external rotation, with a progressively anterior, inferior, and lateral shift in articulation with sequential sectioning of the posterior cable. Lastly, with regards to alterations in glenohumeral joint force, no significant changes were seen in any of the conditions. Conclusion: In this cadaveric shoulder model of the throwing shoulder, tears of the posterior rotator cuff cable lead to altered glenohumeral biomechanics and kinematics. These changes were most profound at 120° of external rotation, suggesting the importance of an intact posterior cable as a potential stabilizer during the late-cocking phase of throwing.

  5. Tear oxygen under hydrogel and silicone hydrogel contact lenses in humans.

    PubMed

    Bonanno, Joseph A; Clark, Christopher; Pruitt, John; Alvord, Larry

    2009-08-01

    To determine the tear oxygen tension under a variety of conventional and silicone hydrogel contact lenses in human subjects. Three hydrogel and five silicone hydrogel lenses (Dk/t = 17 to 329) were coated on the back surface with an oxygen sensitive, bovine serum albumin-Pd meso-tetra (4-carboxyphenyl) porphine complex (BSA-porphine). Each lens type was placed on the right eye of 15 non-contact lens wearers to obtain a steady-state open eye tear oxygen tension using oxygen sensitive phosphorescence decay of BSA-porphine. A closed-eye oxygen tension estimate was obtained by measuring the change in tear oxygen tension after 5 min of eye closure. In separate experiments, a goggle was placed over the lens wearing eye and a gas mixture (PO2 = 51 torr) flowed over the lens to simulate anterior lens oxygen tension during eye closure. Mean open eye oxygen tension ranged from 58 to 133 torr. Closed eye estimates ranged from 11 to 42 torr. Oxygen tension under the goggle ranged from 8 to 48 torr and was higher than the closed eye estimate for six out of the eight lenses, suggesting that the average closed eye anterior lens surface oxygen tension is <51 torr. For Dk/t >30, the measured tear oxygen tension is significantly lower than that predicted from previous studies. The phosphorescence decay methodology is capable of directly measuring the in vivo post lens PO2 of high Dk/t lenses without disturbing the contact lens or cornea. Our data indicate that increasing Dk/t up to and beyond 140 continues to yield increased flux into the central cornea.

  6. Crack Growth Simulation and Residual Strength Prediction in Airplane Fuselages

    NASA Technical Reports Server (NTRS)

    Chen, Chuin-Shan; Wawrzynek, Paul A.; Ingraffea, Anthony R.

    1999-01-01

    The objectives were to create a capability to simulate curvilinear crack growth and ductile tearing in aircraft fuselages subjected to widespread fatigue damage and to validate with tests. Analysis methodology and software program (FRANC3D/STAGS) developed herein allows engineers to maintain aging aircraft economically, while insuring continuous airworthiness, and to design more damage-tolerant aircraft for the next generation. Simulations of crack growth in fuselages were described. The crack tip opening angle (CTOA) fracture criterion, obtained from laboratory tests, was used to predict fracture behavior of fuselage panel tests. Geometrically nonlinear, elastic-plastic, thin shell finite element crack growth analyses were conducted. Comparisons of stress distributions, multiple stable crack growth history, and residual strength between measured and predicted results were made to assess the validity of the methodology. Incorporation of residual plastic deformations and tear strap failure was essential for accurate residual strength predictions. Issue related to predicting crack trajectory in fuselages were also discussed. A directional criterion, including T-stress and fracture toughness orthotropy, was developed. Curvilinear crack growth was simulated in coupon and fuselage panel tests. Both T-stress and fracture toughness orthotropy were essential to predict the observed crack paths. Flapping of fuselages were predicted. Measured and predicted results agreed reasonable well.

  7. A comparison of basal and eye-flush tears for the analysis of cat tear proteins.

    PubMed

    Petznick, Andrea; Evans, Margaret D M; Madigan, Michele C; Markoulli, Maria; Garrett, Qian; Sweeney, Deborah F

    2011-02-01

    To identify a rapid and effective tear collection method providing sufficient tear volume and total protein content (TPC) for analysis of individual proteins in cats. Domestic adult short-haired cats (12-37 months; 2.7-6.6 kg) were used in the study. Basal tears without stimulation and eye-flush tears after instillation of saline (10 μl) were collected using microcapillary tubes from animal eyes either unwounded control or wounded with 9-mm central epithelial debridement giving four groups with n = 3. Tear comparisons were based on total time and rate for tear collection, TPC using micro bicinchoninic acid (BCA), tear immunoglobulin A (IgA), total matrix-metalloproteinase (MMP)-9 concentration using sandwich enzyme-linked immunosorbent assay (ELISA) and MMP-9 activity. Eye-flush tears were collected significantly faster than basal tears in wounded eyes with higher rates for tear collection in unwounded control and wounded eyes. TPC was significantly lower in eye-flush tears compared to basal tears. The relative proportion of tear IgA normalized to TPC (% IgA of TPC) was not significantly different between basal and eye-flush tears. In unwounded control eyes, MMP-9 was slightly higher in eye-flush than in basal tears; activity of MMP-9 in both tear types was similar. In wounded eyes, eye-flush tears showed highest MMP-9 levels and activity on Day 1, which subsequently decreased to Day 7. MMP-9 activity in basal tears from wounded eyes did not display changes in expression. Eye-flush tears can be collected rapidly providing sufficient tear volume and TPC. This study also indicates that eye-flush tears may be more suitable than basal tears for the analysis of MMPs following corneal wounding. © 2011 The Authors. Acta Ophthalmologica © 2011 Acta Ophthalmologica Scandinavica Foundation.

  8. Physically-Based Modelling and Real-Time Simulation of Fluids.

    NASA Astrophysics Data System (ADS)

    Chen, Jim Xiong

    1995-01-01

    Simulating physically realistic complex fluid behaviors presents an extremely challenging problem for computer graphics researchers. Such behaviors include the effects of driving boats through water, blending differently colored fluids, rain falling and flowing on a terrain, fluids interacting in a Distributed Interactive Simulation (DIS), etc. Such capabilities are useful in computer art, advertising, education, entertainment, and training. We present a new method for physically-based modeling and real-time simulation of fluids in computer graphics and dynamic virtual environments. By solving the 2D Navier -Stokes equations using a CFD method, we map the surface into 3D using the corresponding pressures in the fluid flow field. This achieves realistic real-time fluid surface behaviors by employing the physical governing laws of fluids but avoiding extensive 3D fluid dynamics computations. To complement the surface behaviors, we calculate fluid volume and external boundary changes separately to achieve full 3D general fluid flow. To simulate physical activities in a DIS, we introduce a mechanism which uses a uniform time scale proportional to the clock-time and variable time-slicing to synchronize physical models such as fluids in the networked environment. Our approach can simulate many different fluid behaviors by changing the internal or external boundary conditions. It can model different kinds of fluids by varying the Reynolds number. It can simulate objects moving or floating in fluids. It can also produce synchronized general fluid flows in a DIS. Our model can serve as a testbed to simulate many other fluid phenomena which have never been successfully modeled previously.

  9. Virtual reality lead extraction as a method for training new physicians: a pilot study.

    PubMed

    Maytin, Melanie; Daily, Thomas P; Carillo, Roger G

    2015-03-01

    It is estimated that the demand for transvenous lead extraction (TLE) has reached an annual extraction rate of nearly 24,000 patients worldwide. Despite technologic advances, TLE still has the potential for significant morbidity and mortality. Complication rates with TLE directly parallel operator experience. However, obtaining adequate training during and postfellowship can be difficult. Given the potential for catastrophic complications and the steep learning curve (up to 300 cases) associated with this procedure, we sought to validate a virtual reality (VR) lead extraction simulator as an innovative training and evaluation tool for physicians new to TLE. We randomized eight electrophysiology fellows to VR simulator versus conventional training. We compared procedural skill competency between the groups using simulator competency, tactile measurements, markers of proficiency and attitudes, and cognitive abilities battery. Practical skills and simulator complications differed significantly between the VR simulator and conventional training groups. The VR simulator group executed patient preparation and procedure performance better than the conventional group (P < 0.01). All four fellows randomized to conventional training experienced a simulator complication (two superior vena cava [SVC] tears, three right ventricle [RV] avulsions) versus one fellow in the VR simulator group (one SVC tear) (P = 0.02). Tactile measurements revealed a trend toward excess pushing versus pulling forces among the conventionally trained group. The time for lead removal was also significantly higher in the conventional training group (12.46 minutes vs 5.54 minutes, P = 0.02). There was no significant difference in baseline or posttraining cognitive ability. We contend that the implementation of alternative training tools such as a VR simulation model will improve physician training and allow for an innovative pathway to assess the achievement of competency. ©2014 Wiley Periodicals, Inc.

  10. Meniscal tears missed on MR imaging: relationship to meniscal tear patterns and anterior cruciate ligament tears.

    PubMed

    De Smet, A A; Graf, B K

    1994-04-01

    MR imaging of the knee is a valuable technique for diagnosing meniscal tears, but some tears found at arthroscopy are not shown on MR imaging. The purpose of this study was to determine whether or not tears were more frequently missed in the presence of an anterior cruciate ligament tear or when tears had certain locations or configurations. We reviewed the original MR reports and surgical records of 400 patients who had both an MR examination and arthroscopy of the knee. Using chi 2 analysis, we examined how the sensitivity for detecting meniscal tears varied with the presence of a tear of the anterior cruciate ligament, with the location of the tear within the meniscus, and among six configurations of meniscal tears. We also studied whether sensitivity decreased with an increasing delay between MR examination and arthroscopy. In the presence of a tear of the anterior cruciate ligament, the sensitivity decreased from 0.97 to 0.88 (p = .016) for medial meniscal tears and from 0.94 to 0.69 (p = .0005) for lateral tears. The overall sensitivity for lateral meniscal tears was significantly less for posterior (p = .001) and peripheral (p = .005) tears than for other tear locations or configurations. The sensitivities did not significantly differ between tear locations and configurations in the medial meniscus or with an increasing delay until arthroscopy. Patients with a torn anterior cruciate ligament were more likely to have peripheral tears of the medial meniscus (p = .00004) and posterior (p = .0004) and peripheral (p = .04) tears of the lateral meniscus. Because of their location and configuration, meniscal tears associated with an anterior cruciate ligament injury are more difficult to detect on MR images than are tears in knees with an intact ligament. If a tear of the anterior cruciate ligament is detected, special attention should be given to the subtle peripheral tears that may be present in either meniscus, but most commonly in the posterior horn of the lateral meniscus. These tears are especially difficult to detect on MR images.

  11. Gene Expression in Human Accessory Lacrimal Glands of Wolfring

    PubMed Central

    Ubels, John L.; Gipson, Ilene K.; Spurr-Michaud, Sandra J.; Tisdale, Ann S.; Van Dyken, Rachel E.; Hatton, Mark P.

    2012-01-01

    Purpose. The accessory lacrimal glands are assumed to contribute to the production of tear fluid, but little is known about their function. The goal of this study was to conduct an analysis of gene expression by glands of Wolfring that would provide a more complete picture of the function of these glands. Methods. Glands of Wolfring were isolated from frozen sections of human eyelids by laser microdissection. RNA was extracted from the cells and hybridized to gene expression arrays. The expression of several of the major genes was confirmed by immunohistochemistry. Results. Of the 24 most highly expressed genes, 9 were of direct relevance to lacrimal function. These included lysozyme, lactoferrin, tear lipocalin, and lacritin. The glands of Wolfring are enriched in genes related to protein synthesis, targeting, and secretion, and a large number of genes for proteins with antimicrobial activity were detected. Ion channels and transporters, carbonic anhydrase, and aquaporins were abundantly expressed. Genes for control of lacrimal function, including cholinergic, adrenergic, vasoactive intestinal polypeptide, purinergic, androgen, and prolactin receptors were also expressed in gland of Wolfring. Conclusions. The data suggest that the function of glands of Wolfring is similar to that of main lacrimal glands and are consistent with secretion electrolytes, fluid, and protein under nervous and hormonal control. Since these glands secrete directly onto the ocular surface, their location may allow rapid response to exogenous stimuli and makes them readily accessible to topical drugs. PMID:22956620

  12. Inner layer-embedded contact lenses for pH-triggered controlled ocular drug delivery.

    PubMed

    Zhu, Qiang; Liu, Chang; Sun, Zheng; Zhang, Xiaofei; Liang, Ning; Mao, Shirui

    2018-07-01

    Contact lenses (CLs) are ideally suited for controlled ocular drug delivery, but are limited by short release duration, poor storage stability and low drug loading. In this study, we present a novel inner layer-embedded contact lens capable of pH-triggered extended ocular drug delivery with good storage stability. Blend film of ethyl cellulose and Eudragit S100 was used as the inner layer, while pHEMA hydrogel was used as outer layer to fabricate inner layer-embedded contact lens. Using diclofenac sodium(DS) as a drug model, influence of polymer ratio in the blend film, EC viscosity, drug/polymer ratio, inner layer thickness and outlayer thickness of pHEMA hydrogel on drug release behavior was studied and optimized for daily use. The pH-triggered drug eluting pattern enables the inner layer-embedded contact lens being stored in phosphate buffer solution pH 6.8 with ignorable drug loss and negligible changes in drug release pattern. In vivo pharmacokinetic study in rabbits showed sustained drug release for over 24 h in tear fluid, indicating significant improvement in drug corneal residence time. A level A IVIVC was established between in vitro drug release and in vivo drug concentration in tear fluid. In conclusion, this inner layer embedded contact lens design could be used as a platform for extended ocular drug delivery with translational potential for both anterior and posterior ocular diseases therapy. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. Application of a Pore Fraction Hot Tearing Model to Directionally Solidified and Direct Chill Cast Aluminum Alloys

    NASA Astrophysics Data System (ADS)

    Dou, Ruifeng; Phillion, A. B.

    2016-08-01

    Hot tearing susceptibility is commonly assessed using a pressure drop equation in the mushy zone that includes the effects of both tensile deformation perpendicular to the thermal gradient as well as shrinkage feeding. In this study, a Pore Fraction hot tearing model, recently developed by Monroe and Beckermann (JOM 66:1439-1445, 2014), is extended to additionally include the effect of strain rate parallel to the thermal gradient. The deformation and shrinkage pore fractions are obtained on the basis of the dimensionless Niyama criterion and a scaling variable method. First, the model is applied to the binary Al-Cu system under conditions of directional solidification. It is shown that for the same Niyama criterion, a decrease in the cooling rate increases both the deformation and shrinkage pore fractions because of an increase in the time spent in the brittle temperature region. Second, the model is applied to the industrial aluminum alloy AA5182 as part of a finite element simulation of the Direct Chill (DC) casting process. It is shown that an increase in the casting speed during DC casting increases the deformation and shrinkage pore fractions, causing the maximum point of pore fraction to move towards the base of the casting. These results demonstrate that including the strain rate parallel to the thermal gradient significantly improves the predictive quality of hot tearing criteria based on the pressure drop equation.

  14. Tear dynamics in healthy and dry eyes.

    PubMed

    Cerretani, Colin F; Radke, C J

    2014-06-01

    Dry-eye disease, an increasingly prevalent ocular-surface disorder, significantly alters tear physiology. Understanding the basic physics of tear dynamics in healthy and dry eyes benefits both diagnosis and treatment of dry eye. We present a physiological-based model to describe tear dynamics during blinking. Tears are compartmentalized over the ocular surface; the blink cycle is divided into three repeating phases. Conservation laws quantify the tear volume and tear osmolarity of each compartment during each blink phase. Lacrimal-supply and tear-evaporation rates are varied to reveal the dependence of tear dynamics on dry-eye conditions, specifically tear osmolarity, tear volume, tear-turnover rate (TTR), and osmotic water flow. Predicted periodic-steady tear-meniscus osmolarity is 309 and 321 mOsM in normal and dry eyes, respectively. Tear osmolarity, volume, and TTR all match available clinical measurements. Osmotic water flow through the cornea and conjunctiva contribute 10 and 50% to the total tear supply in healthy and dry-eye conditions, respectively. TTR in aqueous-deficient dry eye (ADDE) is only half that in evaporative dry eye (EDE). The compartmental periodic-steady tear-dynamics model accurately predicts tear behavior in normal and dry eyes. Inclusion of osmotic water flow is crucial to match measured tear osmolarity. Tear-dynamics predictions corroborate the use of TTR as a clinical discriminator between ADDE and EDE. The proposed model is readily extended to predict the dynamics of aqueous solutes such as drugs or fluorescent tags.

  15. A Quantitative Proteomics Approach to Clinical Research with Non-Traditional Samples

    PubMed Central

    Licier, Rígel; Miranda, Eric; Serrano, Horacio

    2016-01-01

    The proper handling of samples to be analyzed by mass spectrometry (MS) can guarantee excellent results and a greater depth of analysis when working in quantitative proteomics. This is critical when trying to assess non-traditional sources such as ear wax, saliva, vitreous humor, aqueous humor, tears, nipple aspirate fluid, breast milk/colostrum, cervical-vaginal fluid, nasal secretions, bronco-alveolar lavage fluid, and stools. We intend to provide the investigator with relevant aspects of quantitative proteomics and to recognize the most recent clinical research work conducted with atypical samples and analyzed by quantitative proteomics. Having as reference the most recent and different approaches used with non-traditional sources allows us to compare new strategies in the development of novel experimental models. On the other hand, these references help us to contribute significantly to the understanding of the proportions of proteins in different proteomes of clinical interest and may lead to potential advances in the emerging field of precision medicine. PMID:28248241

  16. A Quantitative Proteomics Approach to Clinical Research with Non-Traditional Samples.

    PubMed

    Licier, Rígel; Miranda, Eric; Serrano, Horacio

    2016-10-17

    The proper handling of samples to be analyzed by mass spectrometry (MS) can guarantee excellent results and a greater depth of analysis when working in quantitative proteomics. This is critical when trying to assess non-traditional sources such as ear wax, saliva, vitreous humor, aqueous humor, tears, nipple aspirate fluid, breast milk/colostrum, cervical-vaginal fluid, nasal secretions, bronco-alveolar lavage fluid, and stools. We intend to provide the investigator with relevant aspects of quantitative proteomics and to recognize the most recent clinical research work conducted with atypical samples and analyzed by quantitative proteomics. Having as reference the most recent and different approaches used with non-traditional sources allows us to compare new strategies in the development of novel experimental models. On the other hand, these references help us to contribute significantly to the understanding of the proportions of proteins in different proteomes of clinical interest and may lead to potential advances in the emerging field of precision medicine.

  17. The tear turnover and tear clearance tests - a review.

    PubMed

    Garaszczuk, Izabela K; Montes Mico, Robert; Iskander, D Robert; Expósito, Alejandro Cerviño

    2018-03-01

    The aim is to provide a summary of methods available for the assessment of tear turnover and tear clearance rates. The review defines tear clearance and tear turnover and describes their implication for ocular surface health. Additionally, it describes main types of techniques for measuring tear turnover, including fluorescein tear clearance tests, techniques utilizing electromagnetic spectrum and tracer molecule and novel experimental techniques utilizing optical coherence tomography and fluorescein profilometry. Areas covered: Internet databases (PubMed, Science Direct, Google Scholar) and most frequently cited references were used as a principal resource of information on tear turnover rate and tear clearance rate, presenting methodologies and equipment, as well as their definition and implications for the anterior eye surface health and function. Keywords used for data-search were as follows: tear turnover, tear clearance, fluorescein clearance, scintigraphy, fluorophotometry, tear flow, drainage, tear meniscus dynamics, Krehbiel flow and lacrimal functional unit. Expert commentary: After decades, the topic of tear turnover assessment has been reintroduced. Recently, new techniques have been developed to propose less invasive, less time consuming and simpler methodologies for the assessment of tear dynamics that have the potential to be utilized in clinical practice.

  18. Lymphotoxin-beta receptor blockade reduces CXCL13 in lacrimal glands and improves corneal integrity in the NOD model of Sjögren's syndrome

    PubMed Central

    2011-01-01

    Introduction In Sjögren's syndrome, keratoconjunctivitis sicca (dry eye) is associated with infiltration of lacrimal glands by leukocytes and consequent losses of tear-fluid production and the integrity of the ocular surface. We investigated the effect of blockade of the lymphotoxin-beta receptor (LTBR) pathway on lacrimal-gland pathology in the NOD mouse model of Sjögren's syndrome. Methods Male NOD mice were treated for up to ten weeks with an antagonist, LTBR-Ig, or control mouse antibody MOPC-21. Extra-orbital lacrimal glands were analyzed by immunohistochemistry for high endothelial venules (HEV), by Affymetrix gene-array analysis and real-time PCR for differential gene expression, and by ELISA for CXCL13 protein. Leukocytes from lacrimal glands were analyzed by flow-cytometry. Tear-fluid secretion-rates were measured and the integrity of the ocular surface was scored using slit-lamp microscopy and fluorescein isothiocyanate (FITC) staining. The chemokine CXCL13 was measured by ELISA in sera from Sjögren's syndrome patients (n = 27) and healthy controls (n = 30). Statistical analysis was by the two-tailed, unpaired T-test, or the Mann-Whitney-test for ocular integrity scores. Results LTBR blockade for eight weeks reduced B-cell accumulation (approximately 5-fold), eliminated HEV in lacrimal glands, and reduced the entry rate of lymphocytes into lacrimal glands. Affymetrix-chip analysis revealed numerous changes in mRNA expression due to LTBR blockade, including reduction of homeostatic chemokine expression. The reduction of CXCL13, CCL21, CCL19 mRNA and the HEV-associated gene GLYCAM-1 was confirmed by PCR analysis. CXCL13 protein increased with disease progression in lacrimal-gland homogenates, but after LTBR blockade for 8 weeks, CXCL13 was reduced approximately 6-fold to 8.4 pg/mg (+/- 2.7) from 51 pg/mg (+/-5.3) in lacrimal glands of 16 week old control mice. Mice given LTBR blockade exhibited an approximately two-fold greater tear-fluid secretion than control mice (P = 0.001), and had a significantly improved ocular surface integrity score (P = 0.005). The mean CXCL13 concentration in sera from Sjögren's patients (n = 27) was 170 pg/ml, compared to 92.0 pg/ml for sera from (n = 30) healthy controls (P = 0.01). Conclusions Blockade of LTBR pathways may have therapeutic potential for treatment of Sjögren's syndrome. PMID:22044682

  19. Clinical evaluation of succinylated collagen bandage lenses for ophthalmic applications.

    PubMed

    Hadassah, J; Prakash, D; Sehgal, P K; Agarwal, A; Bhuvaneshwari, N

    2008-01-01

    To study whether succinylated collagen bandage lenses (SCBL) prepared from modified bovine collagen (succinylated collagen) can replace other bandage lenses presently employed to treat various corneal conditions like filamentary keratitis, dry eyes, recurrent corneal erosions, foreign body removal and epithelial trauma. This observational case study included 32 patients (22 female and 10 male): 8 patients for filamentary keratitis (25%), 10 patients for dry eyes (31%), 4 patients for recurrent corneal erosions (13%), 7 patients for foreign body removal (22%) and 3 patients for epithelial trauma (9%). Their eyes were evaluated for biocompatibility, in vivo transparency, patient comfort, corneal fit, best corrected visual acuity (BCVA), tear fluid level and dissolution rate of SCBL. This was carried out over a 24-hour period of time. SCBL exhibited good transparency and remained transparent throughout the period of study (between 0 and 24 h) in the eyes of patients. SCBL did not cause any irritation, discomfort and foreign body sensation in the eye and eyes remained comfortable throughout the experiment. BCVA in the control group of patients was 1.00 (20/20). Mean (+/-SD) BCVA before inserting SCBL (in decimal equivalent) was 0.31 (20/60) +/- 0.18 (range 0.1- 0.66). BCVA (+/-SD) changed to 0.25 (20/80) +/- 0.18 4 h after the application of SCBL and 0.27 (20/70) +/- 0.18 24 h after the application of SCBL, with a safety index of 1.20. The mean (+/-SD) tear fluid level before application of SCBL was 11.9 +/- 5.39 h (range 3-24 mm) and changed to 13.9 +/- 5.68 h (range 5-28 mm) after 4 h of application of SCBL and 15.9 +/- 5.72 h (range 7-30 mm) after 24 h with a safety index of 13 mm. The mean (+/-SD) dissolution rate of SCBL in the control group of patients was 17.8 +/- 8.65 h (range 10-24 h) and the mean (+/-SD) dissolution rate in the experimental group was 22.2 +/- 9.29 h (range 10-24 h). We report the use of SCBL in various corneal conditions. The present study showed that SCBL has complete corneal fit and good comfort in human eyes. Transparency was maintained for a longer period along with fair visual acuity and improvement in tear fluid levels. The disadvantages of other bandage lenses presently used to treat various corneal conditions could be overcome by the use of SCBL lenses. Copyright 2008 S. Karger AG, Basel.

  20. The Onset of Magnetic Reconnection: Tearing Instability in Current Sheets with a Guide Field

    NASA Astrophysics Data System (ADS)

    Daldorff, L. K. S.; Klimchuk, J. A.; Knizhnik, K. J.

    2016-12-01

    Magnetic reconnection is fundamental to many solar phenomena, ranging from coronal heating, to jets, to flares and CMEs. A poorly understood yet crucial aspect of reconnection is that it does not occur until magnetic stresses have built to sufficiently high levels for significant energy release. If reconnection were to happen too soon, coronal heating would be weak and flares would be small. As part of our program to study the onset conditions for magnetic reconnection, we have investigated the instability of current sheets to tearing. Surprisingly little work has been done on this problem for sheets that include a guide field, i.e., for which the field rotates by less than 180 degrees. This is the most common situation on the Sun. We present numerical 3D resistive MHD simulations of several sheets and show how the behaviour depends on the shear angle (rotation). We compare our results to the predictions of linear theory and discuss the nonlinear evolution in terms of plasmoid formation and the interaction of different oblique tearing modes. The relevance to the Sun is explained.

  1. Collisionless kinetic theory of oblique tearing instabilities

    DOE PAGES

    Baalrud, S. D.; Bhattacharjee, A.; Daughton, W.

    2018-02-15

    The linear dispersion relation for collisionless kinetic tearing instabilities is calculated for the Harris equilibrium. In contrast to the conventional 2D geometry, which considers only modes at the center of the current sheet, modes can span the current sheet in 3D. Modes at each resonant surface have a unique angle with respect to the guide field direction. Both kinetic simulations and numerical eigenmode solutions of the linearized Vlasov-Maxwell equations have recently revealed that standard analytic theories vastly overestimate the growth rate of oblique modes. In this paper, we find that this stabilization is associated with the density-gradient-driven diamagnetic drift. Themore » analytic theories miss this drift stabilization because the inner tearing layer broadens at oblique angles sufficiently far that the assumption of scale separation between the inner and outer regions of boundary-layer theory breaks down. The dispersion relation obtained by numerically solving a single second order differential equation is found to approximately capture the drift stabilization predicted by solutions of the full integro-differential eigenvalue problem. Finally, a simple analytic estimate for the stability criterion is provided.« less

  2. Nonlinear Diamagnetic Stabilization of Double Tearing Modes in Cylindrical MHD Simulations

    NASA Astrophysics Data System (ADS)

    Abbott, Stephen; Germaschewski, Kai

    2014-10-01

    Double tearing modes (DTMs) may occur in reversed-shear tokamak configurations if two nearby rational surfaces couple and begin reconnecting. During the DTM's nonlinear evolution it can enter an ``explosive'' growth phase leading to complete reconnection, making it a possible driver for off-axis sawtooth crashes. Motivated by similarities between this behavior and that of the m = 1 kink-tearing mode in conventional tokamaks we investigate diamagnetic drifts as a possible DTM stabilization mechanism. We extend our previous linear studies of an m = 2 , n = 1 DTM in cylindrical geometry to the fully nonlinear regime using the MHD code MRC-3D. A pressure gradient similar to observed ITB profiles is used, together with Hall physics, to introduce ω* effects. We find the diamagnetic drifts can have a stabilizing effect on the nonlinear DTM through a combination of large scale differential rotation and mechanisms local to the reconnection layer. MRC-3D is an extended MHD code based on the libMRC computational framework. It supports nonuniform grids in curvilinear coordinates with parallel implicit and explicit time integration.

  3. Collisionless kinetic theory of oblique tearing instabilities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baalrud, S. D.; Bhattacharjee, A.; Daughton, W.

    The linear dispersion relation for collisionless kinetic tearing instabilities is calculated for the Harris equilibrium. In contrast to the conventional 2D geometry, which considers only modes at the center of the current sheet, modes can span the current sheet in 3D. Modes at each resonant surface have a unique angle with respect to the guide field direction. Both kinetic simulations and numerical eigenmode solutions of the linearized Vlasov-Maxwell equations have recently revealed that standard analytic theories vastly overestimate the growth rate of oblique modes. In this paper, we find that this stabilization is associated with the density-gradient-driven diamagnetic drift. Themore » analytic theories miss this drift stabilization because the inner tearing layer broadens at oblique angles sufficiently far that the assumption of scale separation between the inner and outer regions of boundary-layer theory breaks down. The dispersion relation obtained by numerically solving a single second order differential equation is found to approximately capture the drift stabilization predicted by solutions of the full integro-differential eigenvalue problem. Finally, a simple analytic estimate for the stability criterion is provided.« less

  4. Energy spectrum of tearing mode turbulence in sheared background field

    NASA Astrophysics Data System (ADS)

    Hu, Di; Bhattacharjee, Amitava; Huang, Yi-Min

    2018-06-01

    The energy spectrum of tearing mode turbulence in a sheared background magnetic field is studied in this work. We consider the scenario where the nonlinear interaction of overlapping large-scale modes excites a broad spectrum of small-scale modes, generating tearing mode turbulence. The spectrum of such turbulence is of interest since it is relevant to the small-scale back-reaction on the large-scale field. The turbulence we discuss here differs from traditional MHD turbulence mainly in two aspects. One is the existence of many linearly stable small-scale modes which cause an effective damping during the energy cascade. The other is the scale-independent anisotropy induced by the large-scale modes tilting the sheared background field, as opposed to the scale-dependent anisotropy frequently encountered in traditional critically balanced turbulence theories. Due to these two differences, the energy spectrum deviates from a simple power law and takes the form of a power law multiplied by an exponential falloff. Numerical simulations are carried out using visco-resistive MHD equations to verify our theoretical predictions, and a reasonable agreement is found between the numerical results and our model.

  5. Collisionless kinetic theory of oblique tearing instabilities

    NASA Astrophysics Data System (ADS)

    Baalrud, S. D.; Bhattacharjee, A.; Daughton, W.

    2018-02-01

    The linear dispersion relation for collisionless kinetic tearing instabilities is calculated for the Harris equilibrium. In contrast to the conventional 2D geometry, which considers only modes at the center of the current sheet, modes can span the current sheet in 3D. Modes at each resonant surface have a unique angle with respect to the guide field direction. Both kinetic simulations and numerical eigenmode solutions of the linearized Vlasov-Maxwell equations have recently revealed that standard analytic theories vastly overestimate the growth rate of oblique modes. We find that this stabilization is associated with the density-gradient-driven diamagnetic drift. The analytic theories miss this drift stabilization because the inner tearing layer broadens at oblique angles sufficiently far that the assumption of scale separation between the inner and outer regions of boundary-layer theory breaks down. The dispersion relation obtained by numerically solving a single second order differential equation is found to approximately capture the drift stabilization predicted by solutions of the full integro-differential eigenvalue problem. A simple analytic estimate for the stability criterion is provided.

  6. Tear Oxygen Under Hydrogel and Silicone Hydrogel Contact Lenses in Humans

    PubMed Central

    Bonanno, Joseph A.; Clark, Christopher; Pruitt, John; Alvord, Larry

    2011-01-01

    Purpose To determine the tear oxygen tension under a variety of conventional and silicone hydrogel contact lenses in human subjects. Methods Three hydrogel and five silicone hydrogel lenses (Dk/t = 17 to 329) were coated on the back surface with an oxygen sensitive, bovine serum albumin-Pd meso-tetra (4-carboxyphenyl) porphine complex (BSA-porphine). Each lens type was placed on the right eye of 15 non-contact lens wearers to obtain a steady-state open eye tear oxygen tension using oxygen sensitive phosphorescence decay of BSA-porphine. A closed-eye oxygen tension estimate was obtained by measuring the change in tear oxygen tension after 5 min of eye closure. In separate experiments, a goggle was placed over the lens wearing eye and a gas mixture (PO2 = 51 torr) flowed over the lens to simulate anterior lens oxygen tension during eye closure. Results Mean open eye oxygen tension ranged from 58 to 133 torr. Closed eye estimates ranged from 11 to 42 torr. Oxygen tension under the goggle ranged from 8 to 48 torr and was higher than the closed eye estimate for six out of the eight lenses, suggesting that the average closed eye anterior lens surface oxygen tension is <51 torr. For Dk/t >30, the measured tear oxygen tension is significantly lower than that predicted from previous studies. Conclusions The phosphorescence decay methodology is capable of directly measuring the in vivo post lens PO2 of high Dk/t lenses without disturbing the contact lens or cornea. Our data indicate that increasing Dk/t up to and beyond 140 continues to yield increased flux into the central cornea. PMID:19609230

  7. Tear progression of symptomatic full-thickness and partial-thickness rotator cuff tears as measured by repeated MRI.

    PubMed

    Kim, Yang-Soo; Kim, Sung-Eun; Bae, Sung-Ho; Lee, Hyo-Jin; Jee, Won-Hee; Park, Chang Kyun

    2017-07-01

    The purpose of this study was to analyse the natural course of symptomatic full-thickness and partial-thickness rotator cuff tears treated non-operatively and to identify risk factors affecting tear enlargement. One hundred and twenty-two patients who received non-surgical treatment for a partial- or full-thickness supraspinatus tear were included in this study. All rotator cuff tears were diagnosed with magnetic resonance imaging (MRI), and the same modality was used for follow-up studies. Follow-up MRI was performed after at least a 6-month interval. We evaluated the correlation between tear enlargement and follow-up duration. Eleven risk factors were analysed by both univariate and multivariate analyses to identify factors that affect enlargement of rotator cuff tears. The mean follow-up period was 24.4 ± 19.5 months. Out of 122 patients, 34 (27.9%) patients had an initial full-thickness tear and 88 (72.1%) patients had a partial-thickness tear. Considering all patients together, tear size increased in 51/122 (41.8%) patients, was unchanged in 65/122 (53.3%) patients, and decreased in 6/122 (4.9%) patients. Tear size increased for 28/34 (82.4%) patients with full-thickness tears and 23/88 (26.1%) patients with partial-thickness tears. From the two groups which were followed over 12 months, a higher rate of enlargement was observed in full-thickness tears than in partial-thickness tears (6-12 months, n.s.; 12-24 months, P = 0.002; over 24 months, P < 0.001). Logistic regression revealed that having a full-thickness tear was the most reliable risk factor for tear progression (P < 0.001). This study found that 28/34 (82.4%) of symptomatic full-thickness rotator cuff tears and 23/88 (26.1%) of symptomatic partial-thickness tears increased in size over a follow-up period of 6-100 months. Full-thickness tears showed a higher rate of enlargement than partial-thickness tears regardless of the follow-up duration. Univariate and multivariate analyses suggested that full-thickness tear was the most reliable risk factor for tear enlargement. The clinical relevance of these observations is that full-thickness rotator cuff tears treated conservatively should be monitored more carefully for progression than partial-thickness tears. IV.

  8. Risk Factors for Tear Progression in Symptomatic Rotator Cuff Tears: A Prospective Study of 174 Shoulders.

    PubMed

    Yamamoto, Nobuyuki; Mineta, Mitsuyoshi; Kawakami, Jun; Sano, Hirotaka; Itoi, Eiji

    2017-09-01

    The risk factors for tear progression in symptomatic rotator cuff tears have not been clarified yet. It is important for orthopaedic surgeons to know the natural course of tear progression when nonoperative management is to be chosen. Tears in younger patients, high-activity patients, or heavy laborers would progress in size more than those in older patients, low-activity patients, or light laborers. Case-control study; Level of evidence, 3. Two hundred twenty-five consecutive patients with symptomatic rotator cuff tears visited our institute between 2009 and 2015. Of these, 174 shoulders of 171 patients (mean age, 66.9 years) who underwent at least 2 magnetic resonance imaging (MRI) examinations were prospectively enrolled. The mean follow-up was 19 months. Tear progression was defined as positive when the tear size increased by ≥2 mm. The demographic factors that were analyzed by multivariate analysis included age, sex, hand dominance, smoking, alcohol drinking, hypercholesterolemia, sports participation, job type, tear size, and tear type (full or partial thickness). Of the 174 shoulders, 82 shoulders (47%) showed tear progression. The mean (±SD) tear length and width in the progression group on final MRI were 23.1 ± 12.5 mm and 17.3 ± 9.6 mm, respectively; the tear size progressed by a mean 5.8 ± 5.6 mm in length and 3.1 ± 5.2 mm in width. The mean propagation speed was 3.8 mm/y in length and 2.0 mm/y in width. The size of full-thickness tears significantly increased compared with that of articular-sided partial-thickness tears ( P = .0215). The size of medium tears significantly increased compared with that of other tears ( P < .0001). According to the logistic regression analysis, smoking was significantly correlated with tear progression ( P = .026). Subgroup analyses showed that male sex, hand dominance, and trauma were correlated with tear progression. Age, alcohol drinking, hypercholesterolemia, sports participation, and job type did not show any correlation with tear progression. The tear size of symptomatic rotator cuff tears progressed in 47% of the shoulders during a mean of 19 months, and the speed of progression was 3.8 mm/y in length and 2.0 mm/y in width. The risk factors for tear progression were (1) a medium-sized tear, (2) a full-thickness tear, and (3) smoking.

  9. Structure and microanalysis of tear film ferning of camel tears, human tears, and Refresh Plus.

    PubMed

    Am, Masmali; Ra, Fagehi; El-Naggar, Ahmad H; Tm, Almubrad

    2018-01-01

    This study aimed to investigate the tear ferning pattern and chemical elements of the tear film of camel tears compared with human tears and Refresh Plus eye lubricant. Refresh Plus was used as a control because it provides a healthy ferning pattern, due to the presence of an optimum ratio of carboxymethylcellulose (CMC) sodium and electrolytes. The main research focus is elucidating the viability of camel tear film in the dry, harsh environment of the desert. The tears were collected from five camels, five male desert workers (20-25 years old) at a small village located 100 km from Riyadh, Saudi Arabia, and five male subjects (20-25 years old) from Riyadh. A small drop (1 μl) of tears was dried on a glass slide and observed under a light (Olympus BX1) and scanning electron microscope (Inspect S50, Field Electron and Ion Company [FEI]). Energy-dispersive X-ray spectroscopy (EDS) of the tear film and Refresh Plus were investigated with a JEOL 1400 scanning transmission electron microscope. The camel tear film pattern was surrounded by thick, peripheral, homogenous layers containing small oily droplets, particles, and tiny branches in the tear ferning. The tear ferning of the camel was grade 0-1, whereas the tear ferning of human tears and Refresh Plus was grade 1-2. The mass percentage of chloride was highest in the camel tears. The mass percentage of potassium in the camel tears was greater than that in the human tears, but it was less than that in the Refresh Plus lubricant. Camel tears exhibit a better quality than human tears and Refresh Plus lubricant do. The presence of oily droplet-like structures at the periphery of tear ferning suggests that camel tear film may have a higher quality and quantity of minerals and lubricants, which may help the animal to avoid eye dryness. Future work is required to investigate the identification of the elements present in the peripheral and central part of the tear ferning.

  10. Effects of Menthol-Containing Artificial Tears on Tear Stimulation and Ocular Surface Integrity in Normal and Dry Eye Rat Models.

    PubMed

    Ahn, Somin; Eom, Youngsub; Kang, Boram; Park, Jungboung; Lee, Hyung Keun; Kim, Hyo Myung; Song, Jong Suk

    2018-05-01

    To evaluate the effects of menthol-containing artificial tears on tear stimulation and ocular surface integrity in normal and dry eye rat models. A total of 54 male Lewis rats were used. The levels of tear secretion and tear MUC5AC concentrations were compared between the menthol-containing artificial tear-treated group (menthol group) and the vehicle-treated group (vehicle group). The groups were compared after a single instillation to evaluate the immediate effects, and after repeated instillation (five times a day for 5 days) to evaluate the longer-term effects. Tear lactate dehydrogenase (LDH) activity was measured to evaluate eye drop instillation-induced ocular surface damage. The effects of menthol-containing artificial tears were also evaluated in a dry eye rat model. After a single instillation of menthol-containing artificial tears, tear secretion increased from 4.37 (±0.75) mm at baseline to 7.37 (±1.60) mm. However, after repeated instillations, the effects of tear stimulation decreased. The tear MUC5AC concentration was significantly lower in the menthol group than in the vehicle group after a single instillation, but not after repeated instillation. However, the tear LDH concentration was significantly increased in the menthol group after repeated instillation. In the dry eye rat model, the extent of menthol-induced tear stimulation was reduced. Menthol-containing artificial tears increased tear secretion, but lowered the tear MUC5AC concentration. Menthol-induced tear stimulation was reduced after repeated instillation for 5 days and in the dry eye rat model. Conversely, repeated instillation of menthol-induced ocular surface damage, resulting in increased tear LDH activity.

  11. Plasminogen activator activity in tears of pregnant women.

    PubMed

    Csutak, Adrienne; Steiber, Zita; Tőzsér, József; Jakab, Attila; Berta, András; Silver, David M

    2017-01-01

    Plasminogen activator activity (PAA) in tears of pregnant women was investigated at various gestation times to assess the availability of plasminogen activator for aiding potential corneal wound healing processes during pregnancy. PAA was measured by a spectrophotometric method. The analysis used 91 tear samples from pregnant and non-pregnant women, supplemented with 10 additional tear PAA measurements from non-pregnant women obtained in a previous study. Tear levels of PAA in pregnant women formed a bimodal distribution. Either the tear PAA level was zero or non-zero during pregnancy. When non-zero, the tear PAA level was dissociated from gestation time and not different than non-pregnant and post-pregnant levels. The frequency of occurrence of zero level tear PAA increased with gestation: 16%, 17% and 46% had zero tear PAA in samples taken from women in the first, second and third trimester, respectively. Overall, of the tear samples taken from women during pregnancy, a total of 26% were at zero tear PAA. The remaining tear samples had non-zero tear PAA values throughout gestation equivalent to non-pregnant tear PAA values, suggesting local control of the source of PAA in tears. Given the importance of the plasminogen activator system in tears to wound healing in the cornea, and the high occurrence of zero tear PAA in our sample of pregnant women, elective corneal surgery would be contraindicated. If corneal surgery is nevertheless necessary, the tear PAA level would be worth checking and patients with low level should be closely observed during the postoperative period.

  12. Levels of interleukin-6 in tears before and after excimer laser treatment.

    PubMed

    Resan, Mirko; Stanojević, Ivan; Petković, Aleksandra; Pajić, Bojan; Vojvodić, Danilo

    2015-04-01

    Immune response and consequent inflammatory process which originate on ocular surface after a trauma are mediated by cytokines. Photoablation of corneal stroma performed by excimer laser causes surgically induced trauma. Interleukin-6 (IL-6) is mostly known as a proinflammatory cytokine. However, it also has regenerative and anti-inflammatory effects. It is supposed that this cytokine is likely to play a significant role in the process of corneal wound healing response after photoablation of stroma carried out by laser in situ keratomileusis (LASIK) or photorefractive keratectomy (PRK) methods. The aim of this study was to determine and compare the levels of IL-6 in tears before and after treatment with LASIK and PRK methods. The study included 68 shortsighted eyes up to -3.0 diopter sphere, i.e. 198 samples of tears (per three samples taken from each of the eyes), divided into two groups according to the kind of excimer laser intervention performed: the group 1--eyes treated by LASIK method (n=31), and the group 2--eyes treated by the PRK method (n=37). The samples of tears were taken from each eye at the following time points: before excimer laser treatment (0 h, the control group), 1 h after the treatment (1 h) and 24 h after the treatment (24 h). The patients did not use anti-inflammatory therapy 24 h after the intervention. Tear samples were collected using microsurgical sponge. Level of IL-6 in tear fluid was determined by the flow cytometry method, applying a commercial test kit which allowed cytokine detection from a small sample volume. Results. The values of IL-6 were detectable in 16% of samples before LASIK treatment and in 30% of samples before PRK treatment. One h after the treatment IL-6 was detectable in 29% of samples for the LASIK group and 43% of samples for the PRK group, and 24 h after the treatment it was detectable in 19% of samples for the LASIK group and in 57% of samples for the PRK group. When we analyzed the dynamics of IL76 production in particular groups, we noticed that both in the LASIK and PRK group the number of samples with increased values of IL-6 after 1 h, and after 24 h, was con- siderably larger than the number of samples with decreased values of IL-6 after the intervention. Analyzing the dynamics of IL-6 concentration changes in the 1 h samples vs. 24 h samples there was a statistically significant increase in the number of samples with IL-6 concentration decline in the LASIK group, while at the same time no considerable changes occurred in the PRK group. Comparing average IL-6 values between the two treatment groups in all tear samples at 0 h, 1 h and 24 h after intervention a significantly higher level in the PRK group 24 h after procedure (p = 0.0031) was detected. IL-6 level in tears increases 1 h and 24 h after LASIK and PRK treatments. This increment is significantly larger 24 h after the treatment with the PRK method than with the LASIK method. Changes of IL-6 production levels in tears after excimer laser treatment indicate that this cytokine takes part in the corneal recovery process after stromal photoablation.

  13. How often do surgeons intervene on shoulder labral lesions detected at MR examination? A retrospective review of MR examinations correlated with arthroscopy

    PubMed Central

    2014-01-01

    Objective: We report the prevalence of surgical intervention on shoulder labral lesions detected at MR examinations and how surgeons describe labral tears seen at MR examinations in their arthroscopy reports. Methods: A retrospective review of 100 consecutive patients aged 50 years or younger who had shoulder labral tears on MR and went on to have surgery performed. It was determined whether surgical intervention was performed on the MR lesions. Results: Of these 100 patients, 72 had superior labral anterior to posterior (SLAP) tears, 38 had posterior labral tears and 28 had anterior labral tears on MR examination. All 100 patients went on to arthroscopy. All lesions described on MRI were described on arthroscopy. Of the 72 SLAP tears, 64 were described as fraying on arthroscopy with 51 debrided. The remaining eight SLAP tears were tacked surgically. Of the 38 posterior labral tears, 36 were described as fraying on arthroscopy with 29 debrided and 2 had surgical tacking performed. Of the 28 anterior labral tears described on MR examination, 26 had surgical tacking performed and 2 were debrided. There were four SLAP tears, two anterior labral tears and three posterior labral tears seen on arthroscopy but not seen on MR examination. Conclusion: In this series, a high percentage of SLAP tears and posterior labral tears described on MR examination did not have surgical tacking. Most anterior labral tears had surgical tacking. Based on the above, our surgeons request we describe superior and posterior labral lesions as fraying and/or tearing, unless we can see a displaced tear. Most anterior labral lesions are treated with surgical tacking. Advances in knowledge: MRI allows for sensitive detection of labral tears. The tears often are not clinically significant. PMID:24712320

  14. Rotator cuff tears in children and adolescents: experience at a large pediatric hospital.

    PubMed

    Zbojniewicz, Andrew M; Maeder, Matthew E; Emery, Kathleen H; Salisbury, Shelia R

    2014-06-01

    Prior literature, limited to small case series and case reports, suggests that rotator cuff tears are rare in adolescents. However, we have identified rotator cuff tears in numerous children and adolescents who have undergone shoulder MRI evaluation. The purpose of this study is to describe the prevalence and characteristics of rotator cuff tears in children and adolescents referred for MRI evaluation of the shoulder at a large pediatric hospital and to correlate the presence of rotator cuff tears with concurrent labral pathology, skeletal maturity and patient activity and outcomes. We reviewed reports from 455 consecutive non-contrast MRI and magnetic resonance arthrogram examinations of the shoulder performed during a 2-year period, and following exclusions we yielded 205 examinations in 201 patients (ages 8-18 years; 75 girls, 126 boys). Rotator cuff tears were classified by tendon involved, tear thickness (partial or full), surface and location of tear (when partial) and presence of delamination. We recorded concurrent labral pathology when present. Physeal patency of the proximal humerus was considered open, closing or closed. Statistical analysis was performed to evaluate for a relationship between rotator cuff tears and degree of physeal patency. We obtained patient activity at the time of injury, surgical reports and outcomes from clinical records when available. Twenty-five (12.2%) rotator cuff tears were identified in 17 boys and 7 girls (ages 10-18 years; one patient had bilateral tears). The supraspinatus tendon was most frequently involved (56%). There were 2 full-thickness and 23 partial-thickness tears with articular-side partial-thickness tears most frequent (78%). Insertional partial-thickness tears were more common (78%) than critical zone tears (22%) and 10 (43%) partial-thickness tears were delamination tears. Nine (36%) patients with rotator cuff tears had concurrent labral pathology. There was no statistically significant relationship between rotator cuff tears and physeal patency (P > 0.05). Most patients were athletes (76%). Five tears were confirmed at surgery. Poor clinical follow-up limited evaluation of patient outcomes. Rotator cuff tears can be identified during MRI examination of symptomatic child and adolescent shoulders and often consist of tear patterns associated with repetitive microtrauma in overhead athletic activities or with single traumatic events. Rotator cuff tears are seen throughout the range of skeletal maturity, often coexist with labral tears and typically are found in athletes.

  15. Surfactant properties of human meibomian lipids.

    PubMed

    Mudgil, Poonam; Millar, Thomas J

    2011-03-25

    Human meibomian lipids are the major part of the lipid layer of the tear film. Their surfactant properties enable their spread across the aqueous layer and help maintain a stable tear film. The purpose of this study was to investigate surfactant properties of human meibomian lipids in vitro and to determine effects of different physical conditions such as temperature and increased osmolarity, such as occur in dry eye, on these properties. Human meibomian lipids were spread on an artificial tear solution in a Langmuir trough. The lipid films were compressed and expanded to record the surface pressure-area (Π-A) isocycles. The isocycles were recorded under different physical conditions such as high pressure, increasing concentration and size of divalent cations, increasing osmolarity, and varying temperature. Π-A isocycles of meibomian lipids showed that they form liquid films that are compressible and multilayered. The isocycles were unaffected by increasing concentration or size of divalent cations and increasing osmolarity in the subphase. Temperature had a marked effect on the lipids. Increase in temperature caused lipid films to become fluid, an expected feature, but decrease in temperature unexpectedly caused expansion of lipids and an increase in pressure suggesting enhanced surfactant properties. Human meibomian lipids form highly compressible, non-collapsible, multilayered liquid films. These lipids have surfactants that allow them to spread across an aqueous subphase. Their surfactant properties are unaffected by increasing divalent cations or hyperosmolarity but are sensitive to temperature. Cooling of meibomian lipids enhances their surfactant properties.

  16. Soft, smart contact lenses with integrations of wireless circuits, glucose sensors, and displays

    PubMed Central

    Park, Jihun; Kim, Joohee; Kim, So-Yun; Cheong, Woon Hyung; Jang, Jiuk; Park, Young-Geun; Na, Kyungmin; Kim, Yun-Tae; Heo, Jun Hyuk; Lee, Chang Young; Lee, Jung Heon; Bien, Franklin; Park, Jang-Ung

    2018-01-01

    Recent advances in wearable electronics combined with wireless communications are essential to the realization of medical applications through health monitoring technologies. For example, a smart contact lens, which is capable of monitoring the physiological information of the eye and tear fluid, could provide real-time, noninvasive medical diagnostics. However, previous reports concerning the smart contact lens have indicated that opaque and brittle components have been used to enable the operation of the electronic device, and this could block the user’s vision and potentially damage the eye. In addition, the use of expensive and bulky equipment to measure signals from the contact lens sensors could interfere with the user’s external activities. Thus, we report an unconventional approach for the fabrication of a soft, smart contact lens in which glucose sensors, wireless power transfer circuits, and display pixels to visualize sensing signals in real time are fully integrated using transparent and stretchable nanostructures. The integration of this display into the smart lens eliminates the need for additional, bulky measurement equipment. This soft, smart contact lens can be transparent, providing a clear view by matching the refractive indices of its locally patterned areas. The resulting soft, smart contact lens provides real-time, wireless operation, and there are in vivo tests to monitor the glucose concentration in tears (suitable for determining the fasting glucose level in the tears of diabetic patients) and, simultaneously, to provide sensing results through the contact lens display. PMID:29387797

  17. Soft, smart contact lenses with integrations of wireless circuits, glucose sensors, and displays.

    PubMed

    Park, Jihun; Kim, Joohee; Kim, So-Yun; Cheong, Woon Hyung; Jang, Jiuk; Park, Young-Geun; Na, Kyungmin; Kim, Yun-Tae; Heo, Jun Hyuk; Lee, Chang Young; Lee, Jung Heon; Bien, Franklin; Park, Jang-Ung

    2018-01-01

    Recent advances in wearable electronics combined with wireless communications are essential to the realization of medical applications through health monitoring technologies. For example, a smart contact lens, which is capable of monitoring the physiological information of the eye and tear fluid, could provide real-time, noninvasive medical diagnostics. However, previous reports concerning the smart contact lens have indicated that opaque and brittle components have been used to enable the operation of the electronic device, and this could block the user's vision and potentially damage the eye. In addition, the use of expensive and bulky equipment to measure signals from the contact lens sensors could interfere with the user's external activities. Thus, we report an unconventional approach for the fabrication of a soft, smart contact lens in which glucose sensors, wireless power transfer circuits, and display pixels to visualize sensing signals in real time are fully integrated using transparent and stretchable nanostructures. The integration of this display into the smart lens eliminates the need for additional, bulky measurement equipment. This soft, smart contact lens can be transparent, providing a clear view by matching the refractive indices of its locally patterned areas. The resulting soft, smart contact lens provides real-time, wireless operation, and there are in vivo tests to monitor the glucose concentration in tears (suitable for determining the fasting glucose level in the tears of diabetic patients) and, simultaneously, to provide sensing results through the contact lens display.

  18. Model of transient drug diffusion across cornea.

    PubMed

    Zhang, Wensheng; Prausnitz, Mark R; Edwards, Aurélie

    2004-09-30

    A mathematical model of solute transient diffusion across the cornea to the anterior chamber of the eye was developed for topical drug delivery. Solute bioavailability was predicted given solute molecular radius and octanol-to-water distribution coefficient (Phi), ocular membrane ultrastructural parameters, tear fluid hydrodynamics, as well as solute distribution volume (Vd) and clearance rate (Cla) in the anterior chamber. The results suggest that drug bioavailability is primarily determined by solute lipophilicity. In human eyes, bioavailability is predicted to range between 1% and 5% for lipophilic molecules (Phi>1), and to be less than 0.5% for hydrophilic molecules (Phi<0.01). The simulations indicate that the distribution coefficient that maximizes bioavailability is on the order of 10. It was also found that the maximum solute concentration in the anterior chamber (Cmax) and the time needed to reach Cmax significantly depend on Phi, Vd, and Cla. Consistent with experimental findings, model predictions suggest that drug bioavailability can be increased by lowering the conjunctival-to-corneal permeability ratio and reducing precorneal solute drainage. Because of its mechanistic basis, this model will be useful to predict drug transport kinetics and bioavailability for new compounds and in diseased eyes.

  19. Incidence and patterns of meniscal tears accompanying the anterior cruciate ligament injury: possible local and generalized risk factors.

    PubMed

    Mansori, Ashraf El; Lording, Timothy; Schneider, Antoine; Dumas, Raphael; Servien, Elvire; Lustig, Sebastien

    2018-05-26

    Injury to the anterior cruciate ligament (ACL) is frequently accompanied by tears of the menisci. Some of these tears occur at the time of injury, but others develop over time in the ACL-deficient knee. The aim of this study was to evaluate the effects of the patient characteristics, time from injury (TFI), and posterior tibial slope (PTS) on meniscal tear patterns. Our hypothesis was that meniscal tears would occur more frequently in ACL-deficient knees with increasing age, weight, TFI, PTS, and in male patients. Of the ACL-injured patients, 362 were analyzed, and details of meniscal lesions were collected. The medial and lateral tibial slopes (MTS, LTS) were measured via computed tomography. Patient demographics, TFI, MTS, and LTS were correlated with the diagnosed meniscal tears. Of the patients, 113 had a medial meniscus (MM) tear, 54 patients had a lateral meniscus (LM) tear, 34 patients had tears of both menisci, and 161 patients had no meniscal tear. The most common tear location was the posterior horn (PH) of the MM, followed by tear involving the whole MM. Patient age, BMI, and TFI were significantly associated with the incidence of MM tear. Female patients had a higher incidence of injury than males in all tear sites except in the body and PH. Male patients had more vertical and peripheral tears. The median MTS and LTS for patients with MM tears were 7.0°and 8.7°, respectively, while those of patients with LM tears were 6.9° and 8.1°. Steeper LTS was significantly associated with tears of LM and of both menisci. Older age, male sex, increased BMI, and prolonged TFI were significant factors for the development of MM tears. An increase in the tibial slope, especially of the lateral plateau, seems to increase the risk of tear of the LM and of both menisci. Level III.

  20. Symptomatic rotator cuff tears show higher radioisotope uptake on bone scintigraphy compared with asymptomatic tears.

    PubMed

    Koike, Yoichi; Sano, Hirotaka; Kita, Atushi; Itoi, Eiji

    2013-09-01

    Some patients with rotator cuff tears complain of pain, whereas others are asymptomatic. Previous studies have pointed out the presence of active bone metabolism in the painful shoulder, identified with increased radioisotope uptake during bone scintigraphy. Shoulders with symptomatic rotator cuff tears will demonstrate higher radioisotope uptake than shoulders with asymptomatic tears with bone scintigraphy, reflecting active bone metabolism in symptomatic tears. Cross-sectional study; Level of evidence, 3. The study consisted of 3 groups: patients with symptomatic tears (symptomatic group), patients with asymptomatic tears (asymptomatic group), and controls (no tear group). The symptomatic group consisted of 28 shoulders from 28 patients with symptomatic rotator cuff tears (pain score ≤4 on the University of California, Los Angeles [UCLA] shoulder evaluation form) who underwent bone scintigraphy followed by rotator cuff repair. Of 70 volunteers who had previously undergone bone scintigraphy for diseases unrelated to their shoulder, 34 were selected for the asymptomatic group (pain score ≥8 on the UCLA shoulder form), and 32 were selected for the no tear group. The mean radioisotope uptake in the symptomatic group was significantly higher than that in the asymptomatic group (P = .02) and the no tear group (P = .02). Ten of 28 shoulders (36%) in the symptomatic group showed increased radioisotope uptake exceeding 2 standard deviations from the mean of the no tear group. This percentage was significantly higher when compared with the asymptomatic group (0%) (P < .01). Shoulders with a symptomatic rotator cuff tear showed higher radioisotope uptake on bone scintigraphy than those with an asymptomatic tear. The radioisotope uptake in shoulders with an asymptomatic tear was comparable with that in shoulders without a tear. Positive radioisotope uptake may be associated with pain in a subgroup of patients with rotator cuff tears.

  1. Direct measurement of hoop strains in the intact and torn human medial meniscus.

    PubMed

    Jones, R Spencer; Keene, G C R; Learmonth, D J A; Bickerstaff, D; Nawana, N S; Costi, J J; Pearcy, M J

    1996-07-01

    OBJECTIVE: To measure the circumferential or hoop strains generated in the medial meniscus during loading of the knee joint and to examine the effect of longitudinal and radial tears in the meniscus on these strain values. DESIGN: An in vitro investigation measuring the circumferential strains in the medial menisci of cadaveric human knees as they were loaded in a materials testing machine. BACKGROUND: The menisci transmit approximately 50% of the load through the knee, the rest being transmitted by direct contact of the articular cartilage. Damage to the menisci will alter the pattern of load transmission as will meniscectomy. This study examined the changes in the mechanics of the meniscus in situ as a result of simulated tears to assess the effect of its load carrying capacity and the implications of surgery to remove part or all of a damaged meniscus. METHODS: Nineteen human cadaveric knees were tested. Windows were made in the joint capsule and strain gauges inserted into the anterior, middle and posterior sections of the medial meniscus. The knees were then loaded to three times body weight at speeds of 50 and 500 mm/min, with the knee joint at 0 degrees and 30 degrees of flexion. The tests were repeated following the creation of a longitudinal or a radial tear in the meniscus. RESULTS: The intact menisci showed significantly less strain in the posterior section compared to the anterior and middle sections (P < 0.003, with strains of 1.54%, 2.86% and 2.65% respectively). With a longitudinal tear this pattern changed with strains decreasing anteriorly and increasing posteriorly. There were also significant differences at different angles of knee joint flexion not seen in the intact meniscus. 50% radial tears reduced the strains anteriorly whilst a complete radial tear completely defunctioned the meniscus. CONCLUSIONS: This study has shown that there are significantly different hoop strains produced in different sections of the medial meniscus under load and the patterns of strain distribution are disturbed by meniscal tears. RELEVANCE: These results provide important data for mathematical models which must include non-uniform behaviour. They also have implications for the surgical management of torn menisci. Undamaged portions should be preserved and the integrity of the circumferential fibres maintained to ensure the menisci retain a load bearing capability.

  2. Size heterogeneity of epidermal growth factor in human body fluids

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pesonen, K.; Viinikka, L.; Koskimies, A.

    The authors measured the concentration of immunoreactive (IR) hEGF in various body fluids by radioimmunoassay (RIA) and evaluated its size heterogeneity by size exclusion high performance liquid chromatography combined with RIA or with time-resolved immunofluorometric assay (TR-IFMA). Mean concentration was 80 ng/ml in urine, 65 ng/ml in milk, 50 ng/ml in seminal plasma, 25 ng/ml in armpit sweat, 1 ng/ml in breast sweat, 0.3 ng/ml in third-trimester amniotic fluid, 3 ng/ml in saliva, 1.5 ng/ml in tears and 0.3 ng/ml in gastric juice. All the fluids except armpit sweat and gastric juice contained two to five molecular sizes of IR-hEGF.more » As well as the 6200-dalton (6.2kDa) hEGF the authors found at least four other different molecular sizes with approximate weights of greater than or equal to300, 150, 70 and 20 kDa. The authentic 6.2kDa form made up >90% of the total IR-hEGF in all except the amniotic fluid where its proportion was 71%, and the seminal plasma where the proportion could not be determined. 18 references, 1 figure, 1 table.« less

  3. Divalent cations in tears, and their influence on tear film stability in humans and rabbits.

    PubMed

    Wei, Xiaojia Eric; Markoulli, Maria; Millar, Thomas J; Willcox, Mark D P; Zhao, Zhenjun

    2012-06-05

    Reduced tear film stability is reported to contribute to dry eye. Rabbits are known to have a more stable tear film than humans. Thus, we sought to examine the tears of rabbits and humans for metal cations, and to test how they influence tear film stability. Tears were collected from 10 healthy humans and 6 rabbits. Tear osmolality was measured by vapor pressure osmometer, and metals analyzed using inductively coupled plasma (ICP) mass spectrometry or ICP atomic emission spectroscopy. The influence of divalent cations on tears was analyzed by measuring surface tension using the Langmuir trough in vitro, using different concentrations of cations in the subphase, and grading the tear break-up in rabbits in vivo after instillation of chelating agents. Rabbit tears had a higher osmolality compared to humans. Major metals did not differ between species; however, rabbits had higher levels of Mg(2+) (1.13 vs. 0.39 mM) and Ca(2+) (0.75 vs. 0.36 mM). In rabbit tears in vitro, diminishing divalent cations resulted in a decrease in the maximum surface pressure from 37 to 30 mN/m. In vivo, an increase in the amount of tear film that was broken-up was found. In contrast, when changing divalent cation concentrations in human tears, the maximum surface pressure remained at 26 mN/m. The normal osmolality of rabbit tears is significantly higher than that in humans. While divalent cations had little influence on human tears, they appear to have an important role in maintaining tear film stability in rabbits.

  4. Increasing age and tear size reduce rotator cuff repair healing rate at 1 year.

    PubMed

    Rashid, Mustafa S; Cooper, Cushla; Cook, Jonathan; Cooper, David; Dakin, Stephanie G; Snelling, Sarah; Carr, Andrew J

    2017-12-01

    Background and purpose - There is a need to understand the reasons why a high proportion of rotator cuff repairs fail to heal. Using data from a large randomized clinical trial, we evaluated age and tear size as risk factors for failure of rotator cuff repair. Patients and methods - Between 2007 and 2014, 65 surgeons from 47 hospitals in the National Health Service (NHS) recruited 447 patients with atraumatic rotator cuff tendon tears to the United Kingdom Rotator Cuff Trial (UKUFF) and 256 underwent rotator cuff repair. Cuff integrity was assessed by imaging in 217 patients, at 12 months post-operation. Logistic regression analysis was used to determine the influence of age and intra-operative tear size on healing. Hand dominance, sex, and previous steroid injections were controlled for. Results - The overall healing rate was 122/217 (56%) at 12 months. Healing rate decreased with increasing tear size (small tears 66%, medium tears 68%, large tears 47%, and massive tears 27% healed). The mean age of patients with a healed repair was 61 years compared with 64 years for those with a non-healed repair. Mean age increased with larger tear sizes (small tears 59 years, medium tears 62 years, large tears 64 years, and massive tears 66 years). Increasing age was an independent factor that negatively influenced healing, even after controlling for tear size. Only massive tears were an independent predictor of non-healing, after controlling for age. Interpretation - Although increasing age and larger tear size are both risks for failure of rotator cuff repair healing, age is the dominant risk factor.

  5. [Predicting the probability of development and progression of primary open angle glaucoma by regression modeling].

    PubMed

    Likhvantseva, V G; Sokolov, V A; Levanova, O N; Kovelenova, I V

    2018-01-01

    Prediction of the clinical course of primary open-angle glaucoma (POAG) is one of the main directions in solving the problem of vision loss prevention and stabilization of the pathological process. Simple statistical methods of correlation analysis show the extent of each risk factor's impact, but do not indicate the total impact of these factors in personalized combinations. The relationships between the risk factors is subject to correlation and regression analysis. The regression equation represents the dependence of the mathematical expectation of the resulting sign on the combination of factor signs. To develop a technique for predicting the probability of development and progression of primary open-angle glaucoma based on a personalized combination of risk factors by linear multivariate regression analysis. The study included 66 patients (23 female and 43 male; 132 eyes) with newly diagnosed primary open-angle glaucoma. The control group consisted of 14 patients (8 male and 6 female). Standard ophthalmic examination was supplemented with biochemical study of lacrimal fluid. Concentration of matrix metalloproteinase MMP-2 and MMP-9 in tear fluid in both eyes was determined using 'sandwich' enzyme-linked immunosorbent assay (ELISA) method. The study resulted in the development of regression equations and step-by-step multivariate logistic models that can help calculate the risk of development and progression of POAG. Those models are based on expert evaluation of clinical and instrumental indicators of hydrodynamic disturbances (coefficient of outflow ease - C, volume of intraocular fluid secretion - F, fluctuation of intraocular pressure), as well as personalized morphometric parameters of the retina (central retinal thickness in the macular area) and concentration of MMP-2 and MMP-9 in the tear film. The newly developed regression equations are highly informative and can be a reliable tool for studying of the influence vector and assessment of pathogenic potential of the independent risk factors in specific personalized combinations.

  6. Coefficient of Friction of Human Corneal Tissue.

    PubMed

    Wilson, Tawnya; Aeschlimann, Rudolf; Tosatti, Samuele; Toubouti, Youssef; Kakkassery, Joseph; Osborn Lorenz, Katherine

    2015-09-01

    A novel property evaluation methodology was used to determine the elusive value for the human corneal coefficient of friction (CoF). Using a microtribometer on 28 fresh human donor corneas with intact epithelia, the CoF was determined in 4 test solutions (≥5 corneas/solution): tear-mimicking solution (TMS) in borate-buffered saline (TMS-PS), TMS in phosphate-buffered saline (TMS-PBS), TMS with HEPES-buffered saline (TMS-HEPES), and tear-like fluid in PBS (TLF-PBS). Mean (SD) CoF values ranged from 0.006 to 0.015 and were 0.013 (0.010) in TMS-PS, 0.006 (0.003) in TMS-PBS, 0.014 (0.005) in TMS-HEPES, and 0.015 (0.009) in TLF-PBS. Statistically significant differences were shown for TMS-PBS versus TLF (P = 0.0424) and TMS-PBS versus TMS-HEPES (P = 0.0179), but not for TMS-PBS versus TMS-PS (P = 0.2389). Successful measurement of the fresh human corneal tissue CoF was demonstrated, with values differing in the evaluated buffer solutions, within this limited sample size.

  7. Secretion of a recombinant protein without a signal peptide by the exocrine glands of transgenic rabbits

    PubMed Central

    Iski, Gergely; Lipták, Nándor; Gócza, Elen; Kues, Wilfried A.; Bősze, Zsuzsanna

    2017-01-01

    Transgenic rabbits carrying mammary gland specific gene constructs are extensively used for excreting recombinant proteins into the milk. Here, we report refined phenotyping of previously generated Venus transposon-carrying transgenic rabbits with particular emphasis on the secretion of the reporter protein by exocrine glands, such as mammary, salivary, tear and seminal glands. The Sleeping Beauty (SB) transposon transgenic construct contains the Venus fluorophore cDNA, but without a signal peptide for the secretory pathway, driven by the ubiquitous CAGGS (CAG) promoter. Despite the absence of a signal peptide, the fluorophore protein was readily detected in milk, tear, saliva and seminal fluids. The expression pattern was verified by Western blot analysis. Mammary gland epithelial cells of SB-CAG-Venus transgenic lactating does also showed Venus-specific expression by tissue histology and fluorescence microscopy. In summary, the SB-CAG-Venus transgenic rabbits secrete the recombinant protein by different glands. This finding has relevance not only for the understanding of the biological function of exocrine glands, but also for the design of constructs for expression of recombinant proteins in dairy animals. PMID:29077768

  8. A Controlled Study on the Correlation between Tear Film Volume and Tear Film Stability in Diabetic Patients.

    PubMed

    Eissa, Iman M; Khalil, Noha M; El-Gendy, Heba A

    2016-01-01

    Purpose. To assess the tear film quantity and correlate it with the quality and stability of the tear film in diabetics and compare them to age matched controls. Introduction. Diabetes affects tear film parameters in multiple ways. Poor metabolic control and neuropathy are postulated factors. To further understand how diabetes affects tear film parameters this study was conducted. Subjects and Methods. Tear meniscus height was measured by anterior segment OCT, along with tear thinning time, a subtype of noninvasive tear break-up time, and blinking rate per minute which were all recorded for 22 diabetic patients. Correlations between these tear film parameters were studied and then compared to 16 age matched controls. Results. A statistically significant difference was found in blinking rate between the diabetic and the control group (P = 0.002), with higher blinking rate among diabetics. All tear film parameters were negatively correlated with duration of diabetes. A positive correlation was found between tear film volume and stability. Conclusion. Diabetes affects the tear film in various ways. Diabetics should be examined for dry eye signs even in absence of symptoms which may be masked by associated neuropathy. Duration of diabetes has an impact on tear film status.

  9. A novel feedback algorithm for simulating controlled dynamics and confinement in the advanced reversed-field pinch

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dahlin, J.-E.; Scheffel, J.

    2005-06-15

    In the advanced reversed-field pinch (RFP), the current density profile is externally controlled to diminish tearing instabilities. Thus the scaling of energy confinement time with plasma current and density is improved substantially as compared to the conventional RFP. This may be numerically simulated by introducing an ad hoc electric field, adjusted to generate a tearing mode stable parallel current density profile. In the present work a current profile control algorithm, based on feedback of the fluctuating electric field in Ohm's law, is introduced into the resistive magnetohydrodynamic code DEBSP [D. D. Schnack and D. C. Baxter, J. Comput. Phys. 55,more » 485 (1984); D. D. Schnack, D. C. Barnes, Z. Mikic, D. S. Marneal, E. J. Caramana, and R. A. Nebel, Comput. Phys. Commun. 43, 17 (1986)]. The resulting radial magnetic field is decreased considerably, causing an increase in energy confinement time and poloidal {beta}. It is found that the parallel current density profile spontaneously becomes hollow, and that a formation, being related to persisting resistive g modes, appears close to the reversal surface.« less

  10. Magnetic and velocity fluctuations from nonlinearly coupled tearing modes in the reversed field pinch with and without the reversal surface

    NASA Astrophysics Data System (ADS)

    Craig, D.; Martin, D.; Den Hartog, D. J.; Nornberg, M. D.; Reusch, J. A.

    2017-08-01

    We investigate the role of poloidal mode number m = 0 fluctuations on m = 1 velocity and magnetic field fluctuations in the Reversed Field Pinch (RFP). Removing the m = 0 resonant surface in the Madison Symmetric Torus (MST), results in suppressed m = 0 activity without a reduction in m = 1 magnetic activity. However, the m = 1 velocity fluctuations and fluctuation-induced mean emf are reduced as m = 0 modes are suppressed. Velocity fluctuations are measured directly using fast Doppler spectroscopy. Similar results are seen in visco-resistive MHD simulation with the DEBS code. An artificial line-averaged velocity diagnostic is developed for DEBS simulations to facilitate direct comparisons with experimental measurements. The sensitivity of the m = 1 velocity fluctuations and corresponding emf to changes in m = 0 mode activity is a feature of tearing modes in the nonlinear regime with a spectrum of interacting modes. These results have implications for RFP sustainment strategies and inform our understanding of the role of magnetic turbulence in astrophysical contexts.

  11. Mechanical testing and finite element analysis of orthodontic teardrop loop.

    PubMed

    Coimbra, Maria Elisa Rodrigues; Penedo, Norman Duque; de Gouvêa, Jayme Pereira; Elias, Carlos Nelson; de Souza Araújo, Mônica Tirre; Coelho, Paulo Guilherme

    2008-02-01

    Understanding how teeth move in response to mechanical loads is an important aspect of orthodontic treatment. Treatment planning should include consideration of the appliances that will meet the desired loading of the teeth to result in optimized treatment outcomes. The purpose of this study was to evaluate the use of computer simulation to predict the force and the torsion obtained after the activation of tear drop loops of 3 heights. Seventy-five retraction loops were divided into 3 groups according to height (6, 7, and 8 mm). The loops were subjected to tensile load through displacements of 0.5, 1.0, 1.5, and 2.0 mm, and the resulting forces and torques were recorded. The loops were designed in AutoCAD software(2005; Autodesk Systems, Alpharetta, GA), and finite element analysis was performed with Ansys software(version 7.0; Swanson Analysis System, Canonsburg, PA). Statistical analysis of the mechanical experiment results was obtained by ANOVA and the Tukey post-hoc test (P < .01). The correlation test and the paired t test (P < .05) were used to compare the computer simulation with the mechanical experiment. The computer simulation accurately predicted the experimentally determined mechanical behavior of tear drop loops of different heights and should be considered an alternative for designing orthodontic appliances before treatment.

  12. Simulation of Semi-Solid Material Mechanical Behavior Using a Combined Discrete/Finite Element Method

    NASA Astrophysics Data System (ADS)

    Sistaninia, M.; Phillion, A. B.; Drezet, J.-M.; Rappaz, M.

    2011-01-01

    As a necessary step toward the quantitative prediction of hot tearing defects, a three-dimensional stress-strain simulation based on a combined finite element (FE)/discrete element method (DEM) has been developed that is capable of predicting the mechanical behavior of semisolid metallic alloys during solidification. The solidification model used for generating the initial solid-liquid structure is based on a Voronoi tessellation of randomly distributed nucleation centers and a solute diffusion model for each element of this tessellation. At a given fraction of solid, the deformation is then simulated with the solid grains being modeled using an elastoviscoplastic constitutive law, whereas the remaining liquid layers at grain boundaries are approximated by flexible connectors, each consisting of a spring element and a damper element acting in parallel. The model predictions have been validated against Al-Cu alloy experimental data from the literature. The results show that a combined FE/DEM approach is able to express the overall mechanical behavior of semisolid alloys at the macroscale based on the morphology of the grain structure. For the first time, the localization of strain in the intergranular regions is taken into account. Thus, this approach constitutes an indispensible step towards the development of a comprehensive model of hot tearing.

  13. Hypertrophy of the extra-articular tendon of the long head of biceps correlates with the location and size of a rotator cuff tear.

    PubMed

    Takahashi, N; Sugaya, H; Matsuki, K; Miyauchi, H; Matsumoto, M; Tokai, M; Onishi, K; Hoshika, S; Ueda, Y

    2017-06-01

    The aim of this study was to assess hypertrophy of the extra-articular tendon of the long head of biceps (LHB) in patients with a rotator cuff tear. The study involved 638 shoulders in 334 patients (175 men, 159 women, mean age 62.6 years; 25 to 81) with unilateral symptomatic rotator cuff tears. The cross-sectional area (CSA) of the LHB tendon in the bicipital groove was measured pre-operatively in both shoulders using ultrasound. There were 154 asymptomatic rotator cuff tears in the contralateral shoulder. Comparisons were made between those with a symptomatic tear, an asymptomatic tear and those with no rotator cuff tear. In the affected shoulders, the CSAs were compared in relation to the location and size of the rotator cuff tear. The mean CSA was 21.0 mm 2 (4 to 71) in those with a symptomatic rotator cuff tear, 19.9 mm 2 (4 to 75) in those with an asymptomatic rotator cuff tear and 14.1 mm 2 (5 to 43) in those with no rotator cuff tear. The mean CSA in patients with both symptomatic and asymptomatic rotator cuff tears was significantly larger than in those with no rotator cuff tear (p < 0.001). In the affected shoulders, there were significant differences between patients with more than a medium sized posterosuperior cuff tear and those with an antero-superior cuff tear. Regardless of the symptoms, there was significant hypertrophy of the extra-articular LHB tendon in patients with a rotator cuff tear. The values were significantly related to the size of the tear. Cite this article: Bone Joint J 2017;99-B:806-11. ©2017 The British Editorial Society of Bone & Joint Surgery.

  14. Increasing age and tear size reduce rotator cuff repair healing rate at 1 year

    PubMed Central

    Rashid, Mustafa S; Cooper, Cushla; Cook, Jonathan; Cooper, David; Dakin, Stephanie G; Snelling, Sarah; Carr, Andrew J

    2017-01-01

    Background and purpose — There is a need to understand the reasons why a high proportion of rotator cuff repairs fail to heal. Using data from a large randomized clinical trial, we evaluated age and tear size as risk factors for failure of rotator cuff repair. Patients and methods — Between 2007 and 2014, 65 surgeons from 47 hospitals in the National Health Service (NHS) recruited 447 patients with atraumatic rotator cuff tendon tears to the United Kingdom Rotator Cuff Trial (UKUFF) and 256 underwent rotator cuff repair. Cuff integrity was assessed by imaging in 217 patients, at 12 months post-operation. Logistic regression analysis was used to determine the influence of age and intra-operative tear size on healing. Hand dominance, sex, and previous steroid injections were controlled for. Results — The overall healing rate was 122/217 (56%) at 12 months. Healing rate decreased with increasing tear size (small tears 66%, medium tears 68%, large tears 47%, and massive tears 27% healed). The mean age of patients with a healed repair was 61 years compared with 64 years for those with a non-healed repair. Mean age increased with larger tear sizes (small tears 59 years, medium tears 62 years, large tears 64 years, and massive tears 66 years). Increasing age was an independent factor that negatively influenced healing, even after controlling for tear size. Only massive tears were an independent predictor of non-healing, after controlling for age. Interpretation — Although increasing age and larger tear size are both risks for failure of rotator cuff repair healing, age is the dominant risk factor. PMID:28880113

  15. Analysis of flow patterns in a patient-specific aortic dissection model.

    PubMed

    Cheng, Z; Tan, F P P; Riga, C V; Bicknell, C D; Hamady, M S; Gibbs, R G J; Wood, N B; Xu, X Y

    2010-05-01

    Aortic dissection is the most common acute catastrophic event affecting the thoracic aorta. The majority of patients presenting with an uncomplicated type B dissection are treated medically, but 25% of these patients develop subsequent aneurysmal dilatation of the thoracic aorta. This study aimed at gaining more detailed knowledge of the flow phenomena associated with this condition. Morphological features and flow patterns in a dissected aortic segment of a presurgery type B dissection patient were analyzed based on computed tomography images acquired from the patient. Computational simulations of blood flow in the patient-specific model were performed by employing a correlation-based transitional version of Menter's hybrid k-epsilon/k-omega shear stress transport turbulence model implemented in ANSYS CFX 11. Our results show that the dissected aorta is dominated by locally highly disturbed, and possibly turbulent, flow with strong recirculation. A significant proportion (about 80%) of the aortic flow enters the false lumen, which may further increase the dilatation of the aorta. High values of wall shear stress have been found around the tear on the true lumen wall, perhaps increasing the likelihood of expanding the tear. Turbulence intensity in the tear region reaches a maximum of 70% at midsystolic deceleration phase. Incorporating the non-Newtonian behavior of blood into the same transitional flow model has yielded a slightly lower peak wall shear stress and higher maximum turbulence intensity without causing discernible changes to the distribution patterns. Comparisons between the laminar and turbulent flow simulations show a qualitatively similar distribution of wall shear stress but a significantly higher magnitude with the transitional turbulence model.

  16. Discrete Element Method Simulation of a Boulder Extraction From an Asteroid

    NASA Technical Reports Server (NTRS)

    Kulchitsky, Anton K.; Johnson, Jerome B.; Reeves, David M.; Wilkinson, Allen

    2014-01-01

    The force required to pull 7t and 40t polyhedral boulders from the surface of an asteroid is simulated using the discrete element method considering the effects of microgravity, regolith cohesion and boulder acceleration. The connection between particle surface energy and regolith cohesion is estimated by simulating a cohesion sample tearing test. An optimal constant acceleration is found where the peak net force from inertia and cohesion is a minimum. Peak pulling forces can be further reduced by using linear and quadratic acceleration functions with up to a 40% reduction in force for quadratic acceleration.

  17. Fluids of the ocular surface: concepts, functions and physics.

    PubMed

    Cher, Ivan

    2012-08-01

    General adoption of the ocular surface (OS) concept has advanced the therapy of the external eye. Fresh physical findings have prompted new concepts; examples taken from each section of the text are: (i) ever-present lipid sealant bridges the palpebral fissure capping the three-dimensional 'OS' sac. The muco-aqueous pool (MAP) is thus enclosed, secluded from atmosphere, evaporation mitigated. Hence, the OS is conceptually, a compartment. The term 'dacruon' (otherwise 'tear film') has been coined for the combined fluids of the OS, viz. lipid film and MAP. (ii) Investigative techniques of physics yield data on (say) surface tension and viscosity, and on functions such as anchorage of dacruon base to the varied mucosae of the OS, lubrication, renovation of intermarginal fluid layers as the eye opens after each blink, and refinement of optics and vision by the fluids attached to the cornea. (iii) Physical events in the opening eye produce the unique 'black line' phenomenon in which capillary force induces subsurface flows into thirsty menisci, bringing about parameniscal dark grooves, pupil-ward of each meniscus. Attenuation of fluorescein in the shallowed fluid gaps behind each groove makes the dye appear unilluminated ('black lines') relative to adjacent full-thickness MAP fluid glowing under cobalt-blue illumination. Isolated from cornea by grooves and gaps, the meniscal fluid cannot pass freely over the cornea. It therefore streams through the menisci to nasolacrimal outflow. © 2012 The Author. Clinical and Experimental Ophthalmology © 2012 Royal Australian and New Zealand College of Ophthalmologists.

  18. Potential Market for New Meniscus Repair Strategies: Evaluation of the MOON Cohort

    PubMed Central

    Fetzer, Gary B.; Spindler, Kurt P.; Amendola, Annunziato; Andrish, Jack T.; Bergfeld, John A.; Dunn, Warren R.; Flanigan, David C.; Jones, Morgan; Kaeding, Christopher C.; Marx, Robert G.; Matava, Matthew J.; McCarty, Eric C.; Parker, Richard D.; Wolcott, Michelle; Vidal, Armando; Wolf, Brian R.; Wright, Rick W.

    2013-01-01

    Background An estimated 200,000 ACL reconstructions are performed each year in the United States. The presence of concomitant meniscus tears and subsequent treatment at the time of ACL reconstruction may determine long-term outcomes of these knees. The authors contend that a substantial number of these meniscal tears are treated in a fashion that reduces meniscal function and that new technologies are needed to treat meniscal tears in a fashion that preserves function. A large cohort of patients with meniscal tears is needed to demonstrate this need. The purpose of this study is to determine the incidence of meniscal tears, describe tear morphology, and selected treatment in the MOON prospective longitudinal cohort of ACL reconstruction. We also will demonstrate based on national statistics the large potential market that exists for future tissue engineering aimed at preserving meniscal function. Methods A multicenter cohort of 1014 patients undergoing ACL reconstruction between January 2002 and December 2003 were evaluated. All procedures were performed by nine fellowship trained sports medicine orthopaedic surgeons. Data on patient demographics, presence of a meniscus tear at time of ACL reconstruction, tear morphology, and meniscal treatment were collected prospectively. Meniscal tears were categorized into three potential tissue engineering treatment strategies: all-biologic repair, advanced repair, and scaffold replacement. Results 1014 ACL reconstructions were performed over the two year period. The median age at the time of surgery was 24 years. Thirty-six percent of the knees had medial meniscal tears and 44% of the knees had lateral meniscal tears. Longitudinal tears were the most common tear morphology. The most frequent treatment modality was partial meniscectomy (60%). Thirty percent of medial meniscal tears and 10% of lateral meniscal tears could be treated with all-biologic repair, 32% of medial meniscal tears and 28% of lateral meniscal tears could be treated with an advanced repair technique, and 35% of medial meniscal tears and 62% of lateral meniscal tears could be treated with scaffold replacement. Conclusions Although meniscal preservation is a generally accepted concept in the treatment of meniscal tears, the majority of tears in this young cohort undergoing ACL reconstruction were either not repairable types (radial) and/or in the avascular zone. Even with contemporary approaches to meniscal tear repair, we found significant limitations faced by the treating surgeon. The majority of tears in this population are currently treated by partial meniscectomy. The results of this cohort will hopefully, stimulate and focus future research and development of new tissue engineering strategies for a large potential market for meniscal function in an ACL reconstructed cohort. PMID:19634719

  19. The prevalence of rotator cuff tears: is the contralateral shoulder at risk?

    PubMed

    Liem, Dennis; Buschmann, Vera Elisa; Schmidt, Carolin; Gosheger, Georg; Vogler, Tim; Schulte, Tobias L; Balke, Maurice

    2014-04-01

    Rotator cuff tears are a common cause of pain and disability of the shoulder. Information on the prevalence and identification of potential risk factors could help in early detection of rotator cuff tears and improve treatment outcome. Patients treated for a symptomatic rotator cuff tear on one side have a higher prevalence of rotator cuff tears and decreased shoulder function on the contralateral side compared with an age- and sex-matched group of healthy individuals. Case control study; Level of evidence, 3. One group consisted of 55 patients who had been arthroscopically treated on one shoulder for rotator cuff tear (tear group). In this group, the nonoperated contralateral shoulder was examined. For comparison, the matching shoulder in a control group consisting of 55 subjectively healthy individuals matched by age (±1 year) and sex to the tear group was included. Diagnosis of a rotator cuff tear was made by ultrasound. Outcomes were measured using the Constant score. The prevalence of supraspinatus tears was significantly higher (P < .0001) in the tear group (67.3%) compared with the control group (11.0%). The Constant score for the activities of daily living subscale, however, was significantly lower (18.4) in the tear group compared with the control group (19.9; P = .012). No other subcategory score nor the overall score showed a significant difference. There was a significantly higher tear prevalence in the tear group of patients aged between 50 and 59 years (P < .001) and 60 and 69 years (P = .004). No tear was diagnosed in the control group in individuals younger than 60 years. Patients treated for partial and full-thickness rotator cuff tears have a significantly higher risk of having a tear on the contralateral side and have noticeable deficits in their shoulder function regarding activities of daily living even if the tear is otherwise asymptomatic.

  20. The Degeneration of Meniscus Roots Is Accompanied by Fibrocartilage Formation, Which May Precede Meniscus Root Tears in Osteoarthritic Knees.

    PubMed

    Park, Do Young; Min, Byoung-Hyun; Choi, Byung Hyune; Kim, Young Jick; Kim, Mijin; Suh-Kim, Haeyoung; Kim, Joon Ho

    2015-12-01

    Fibrocartilage metaplasia in tendons and ligaments is an adaptation to compression as well as a pathological feature during degeneration. Medial meniscus posterior roots are unique ligaments that resist multidirectional forces, including compression. To characterize the degeneration of medial meniscus posterior root tears in osteoarthritic knees, with an emphasis on fibrocartilage and calcification. Cross-sectional study; Level of evidence, 3. Samples of medial meniscus posterior roots were harvested from cadaveric specimens and patients during knee replacement surgery and grouped as follows: normal reference, no tear, partial tear, and complete tear. Degeneration was analyzed with histology, immunohistochemistry, and real-time polymerase chain reaction. Uniaxial tensile tests were performed on specimens with and without fibrocartilage. Quantifiable data were statistically analyzed by the Kruskal-Wallis test with the Dunn comparison test. Thirty, 28, and 42 samples harvested from 99 patients were allocated into the no tear, partial tear, and complete tear groups, respectively. Mean modified Bonar tendinopathy scores for each group were 3.97, 9.31, and 14.15, respectively, showing a higher degree of degeneration associated with the extent of the tear (P < .05 for all groups). The characterization of root matrices revealed an increase in fibrocartilage according to the extent of the tear. Tear margins revealed fibrocartilage in 59.3% of partial tear samples and 76.2% of complete tear samples, with a distinctive cleavage-like shape. Root tears with a similar shape were induced within fibrocartilaginous areas during uniaxial tensile testing. Even in the no tear group, 56.7% of samples showed fibrocartilage in the anterior margin of the root, adjacent to the meniscus. An increased stained area of calcification and expression of the ectonucleotide pyrophosphatase/phosphodiesterase 1 gene were observed in the complete tear group compared with the no tear group (P < .0001 and P = .24, respectively). Fibrocartilage and calcification increased in medial meniscus posterior roots, associated with the degree of the tear. Both findings, which impair the ligament's resistance to tension, may play a pivotal role during the pathogenesis of degenerative meniscus root tears in osteoarthritic knees. Fibrocartilage and calcification may be useful as diagnostic markers as well as markers of degeneration, which may aid in determining the treatment modality in meniscus root tears. The presence of fibrocartilage in intact roots may suggest an impending tear in osteoarthritic knees. © 2015 The Author(s).

  1. Modeling the biomechanical and injury response of human liver parenchyma under tensile loading.

    PubMed

    Untaroiu, Costin D; Lu, Yuan-Chiao; Siripurapu, Sundeep K; Kemper, Andrew R

    2015-01-01

    The rapid advancement in computational power has made human finite element (FE) models one of the most efficient tools for assessing the risk of abdominal injuries in a crash event. In this study, specimen-specific FE models were employed to quantify material and failure properties of human liver parenchyma using a FE optimization approach. Uniaxial tensile tests were performed on 34 parenchyma coupon specimens prepared from two fresh human livers. Each specimen was tested to failure at one of four loading rates (0.01s(-1), 0.1s(-1), 1s(-1), and 10s(-1)) to investigate the effects of rate dependency on the biomechanical and failure response of liver parenchyma. Each test was simulated by prescribing the end displacements of specimen-specific FE models based on the corresponding test data. The parameters of a first-order Ogden material model were identified for each specimen by a FE optimization approach while simulating the pre-tear loading region. The mean material model parameters were then determined for each loading rate from the characteristic averages of the stress-strain curves, and a stochastic optimization approach was utilized to determine the standard deviations of the material model parameters. A hyperelastic material model using a tabulated formulation for rate effects showed good predictions in terms of tensile material properties of human liver parenchyma. Furthermore, the tissue tearing was numerically simulated using a cohesive zone modeling (CZM) approach. A layer of cohesive elements was added at the failure location, and the CZM parameters were identified by fitting the post-tear force-time history recorded in each test. The results show that the proposed approach is able to capture both the biomechanical and failure response, and accurately model the overall force-deflection response of liver parenchyma over a large range of tensile loadings rates. Copyright © 2014 Elsevier Ltd. All rights reserved.

  2. Anterior Segment Optical Coherence Tomography for Tear Meniscus Evaluation and its Correlation with other Tear Variables in Healthy Individuals

    PubMed Central

    Dhasmana, Renu; Nagpal, Ramesh Chander

    2016-01-01

    Introduction Dry eye is one of the most common ocular diseases in this cyber era. Despite availability of multiple tests, no single test is accurate for the diagnosis of dry eye. Anterior segment optical coherence tomography is the recent tool which can be added in the armentarium of dry eye tests. Aim To evaluate tear meniscus with anterior segment optical coherence tomography and its correlation with other tear variables in normal healthy individuals. Materials and Methods In this prospective cross-sectional observational study, right eye of 203 consecutive patients were studied. All the patients were divided into three groups Group 1, 2 and 3 according to their age ≤20 years, 21-40 years and >40 years respectively. All patients underwent routine ophthalmologic examinations along with slit-lamp bio-microscopy for tear meniscus height measurement, tear film break up time, Schirmer’s I test (with anaesthesia) and optical coherence tomography imaging of inferior tear meniscus height. After focusing of the instrument with a Cross Line (CL) centered on lower tear meniscus at 6’0 clock of cornea, a 6 mm long scan was obtained. The tear meniscus height (μm) and tear meniscus area (mm2) were measured manually with help of callipers by joining upper corneo-meniscus junction to the lower lid-meniscus junction and tear meniscus height and area within the plotted line respectively and calculated by using the integrated analysis available in the custom software. Results There was significant decrease in the all tear variables with the increase in the age. According to age groups in group 1, the mean Schirmer’s (24.0±4.9)mm, tear film break up time (11.1±1.9) sec, tear meniscus height on slit lamp (600.2±167.3)mm were higher but decreased in group 2 (21.5±5.4,10.8±1.4, 597.5±186.3) and group 3 (19.8 ± 5.1, 10.2 ± 1.6, 485.6 ± 157.7) respectively. Schirmer’s test values and tear film break up time were similar in both sexes (p=0.1 and p= 0.9). Tear meniscus height on slit lamp and Optical coherence based tear meniscus area were similar in both sexes (p=0.5 and p=0.1). However, tear meniscus height on optical coherence tomography was significantly higher in females (p=0.04). Value of Schirmer’s and tear film break up time (r =0.2; p= 0.001) and Schirmer’s and tear meniscus height on slit lamp (r=0.6; p<0.001) had positive correlation. Tear meniscus height and tear meniscus area on optical coherence tomography had positive correlation (r =.9; p<0.001). Conclusion On optical coherence tomography tear meniscus height and area significantly correlated. Despite higher values of Schirmer’s, tear film break up time, Slit lamp based tear meniscus height in younger age group the tear meniscus height and tear meniscus area with optical coherence tomography were lower. PMID:27437253

  3. TFOS DEWS II Tear Film Report.

    PubMed

    Willcox, Mark D P; Argüeso, Pablo; Georgiev, Georgi A; Holopainen, Juha M; Laurie, Gordon W; Millar, Tom J; Papas, Eric B; Rolland, Jannick P; Schmidt, Tannin A; Stahl, Ulrike; Suarez, Tatiana; Subbaraman, Lakshman N; Uçakhan, Omür Ö; Jones, Lyndon

    2017-07-01

    The members of the Tear Film Subcommittee reviewed the role of the tear film in dry eye disease (DED). The Subcommittee reviewed biophysical and biochemical aspects of tears and how these change in DED. Clinically, DED is characterized by loss of tear volume, more rapid breakup of the tear film and increased evaporation of tears from the ocular surface. The tear film is composed of many substances including lipids, proteins, mucins and electrolytes. All of these contribute to the integrity of the tear film but exactly how they interact is still an area of active research. Tear film osmolarity increases in DED. Changes to other components such as proteins and mucins can be used as biomarkers for DED. The Subcommittee recommended areas for future research to advance our understanding of the tear film and how this changes with DED. The final report was written after review by all Subcommittee members and the entire TFOS DEWS II membership. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. The brilliant beauty of the eye: light reflex from the cornea and tear film.

    PubMed

    Goto, Eiki

    2006-12-01

    Light reflex from the cornea and tear film as contributors to beautiful eyes ("eye sparkling") are reviewed. A systematic literature review was conducted using "Purkinje-Sanson image," "corneal light reflex," "corneal topography," "corneal wavefront aberration," and "tear interference image" as search terms. Articles on corneal surface regularity and stability and tear interferometry of the precorneal tear lipid layer were reviewed. PS-1 image, that is light reflex from the cornea and tear film, is widely used in practical ophthalmic examination. To achieve a brilliant beauty of the eye ("eye sparkling"), it is important that the tear film (aqueous layer) surface is smooth and stable with adequate tear volume and that the tear lipid layer is present in adequate thickness.

  5. A comparison of MRI findings in patients with acute and chronic ACL tears.

    PubMed

    Dimond, P M; Fadale, P D; Hulstyn, M J; Tung, G A; Greisberg, J

    1998-01-01

    This retrospective study compared the magnetic resonance imaging (MRI) findings in 87 patients with acute and chronic anterior cruciate ligament (ACL) tears. Sixty patients had acute tears and 27 had chronic tears. The appearance of the torn ligament was examined on MRI, and associated meniscal and osteochondral injuries were described. All findings were verified at arthroscopy. Acute ACL tears (MRI examination was performed within 6 weeks of injury) were typified by the presence of diffuse (58%) or focal (42%) increased signal within the ligament, whereas chronic ACL tears (MRI examination was performed more than 6 months after injury) usually appeared as either a fragmented ligament (44%) or an intact band of low signal with abnormal orientation (30%). Patients with chronic ACL tears had a higher prevalence of medial meniscal tears (78% versus 40%), articular chondromalacia, and an increased posterior cruciate bow ratio (0.47 versus 0.37) in association with chronic ACL tears. A bone bruise was seen in 68% of acute ACL tears but in no case of chronic ACL tear. On MRI, there are salient differences between acute and chronic ACL tears. Chronic ACL tears are associated with a greater prevalence of meniscal and osteochondral injuries. These findings may have implications for future treatment recommendations.

  6. Simultaneous measurement of tear film dynamics using wavefront sensor and optical coherence tomography.

    PubMed

    Koh, Shizuka; Tung, Cynthia; Aquavella, James; Yadav, Rahul; Zavislan, James; Yoon, Geunyoung

    2010-07-01

    PURPOSE. To investigate tear film dynamics using simultaneous measurements of ocular aberrations and lower tear meniscus. METHODS. Simultaneous measurements of wavefront aberration and lower tear meniscus were performed for 11 normal eyes and 7 eyes with short tear film break-up time (SBUT) dry eye, with a tear film break-up time shorter than 5 seconds, using a wavefront sensor and an anterior segment optical coherence tomography (OCT). During the measurement, the subjects were instructed to blink every 6 seconds for a total of 30 seconds. From the measured aberration, root mean square (RMS) wavefront error and volume modulation transfer function (vMTF) induced by changes in tear film dynamics were calculated for a 5-mm pupil. Lower tear meniscus height (TMH) and area (TMA) were estimated from the cross-sectional OCT images of lower tear meniscus. RESULTS. There was a positive correlation between RMS and tear meniscus dimensions and a negative correlation between vMTF and tear meniscus in both groups. There were moderate negative correlations between the postblink initial RMS change and baseline TMH (R = -0.61) and TMA (R = -0.54) in SBUT dry eyes that were stronger than in normal eyes (R = -0.37, R = -0.38). CONCLUSIONS. Tear meniscus dimensions increase with RMS over time, and tear quantity before blink has a significant role in maintaining initial optical integrity, especially in SBUT dry eye. Simultaneous measurement of optical quality and tear meniscus has the potential to improve understanding of tear stability in normal eyes and dry eyes.

  7. Mass Spectrometric Identification of Phospholipids in Human Tears and Tear Lipocalin

    PubMed Central

    Dean, Austin W.; Glasgow, Ben J.

    2012-01-01

    Purpose. The purpose of this article was to identify by mass spectrometry phosphocholine lipids in stimulated human tears and determine the molecules bound to tear lipocalin or other proteins. Methods. Tear proteins were separated isocratically from pooled stimulated human tears by gel filtration fast performance liquid chromatography. Separation of tear lipocalin was confirmed by SDS tricine gradient PAGE. Protein fractions were extracted with chloroform/methanol and analyzed with electrospray ionization MS/MS triple quadrupole mass spectrometry in precursor ion scan mode for select leaving groups. For quantification, integrated ion counts were derived from standard curves of authentic compounds of phosphatidylcholine (PC) and phosphatidylserine. Results. Linear approximation was possible from integration of the mass spectrometrically obtained ion peaks at 760 Da for the PC standard. Tears contained 194 ng/mL of the major intact PC (34:2), m/z 758.6. Ten other monoisotopic phosphocholines were found in tears. A peak at 703.3 Da was assigned as a sphingomyelin. Four lysophosphatidylcholines (m/z 490–540) accounted for about 80% of the total integrated ion count. The [M+H]+ compound, m/z 496.3, accounted for 60% of the signal intensity. Only the tear lipocalin–bearing fractions showed phosphocholines (104 ng/mL). Although the intact phospholipids bound to tear lipocalin corresponded precisely in mass and relative signal intensity to that found in tears, we did not identify phosphocholines between m/z 490 and 540 in any of the gel-filtration fractions. Conclusions. Phospholipids, predominantly lysophospholipids, are present in tears. The higher mass intact PCs in tears are native ligands of tear lipocalin. PMID:22395887

  8. Mass spectrometric identification of phospholipids in human tears and tear lipocalin.

    PubMed

    Dean, Austin W; Glasgow, Ben J

    2012-04-02

    The purpose of this article was to identify by mass spectrometry phosphocholine lipids in stimulated human tears and determine the molecules bound to tear lipocalin or other proteins. Tear proteins were separated isocratically from pooled stimulated human tears by gel filtration fast performance liquid chromatography. Separation of tear lipocalin was confirmed by SDS tricine gradient PAGE. Protein fractions were extracted with chloroform/methanol and analyzed with electrospray ionization MS/MS triple quadrupole mass spectrometry in precursor ion scan mode for select leaving groups. For quantification, integrated ion counts were derived from standard curves of authentic compounds of phosphatidylcholine (PC) and phosphatidylserine. Linear approximation was possible from integration of the mass spectrometrically obtained ion peaks at 760 Da for the PC standard. Tears contained 194 ng/mL of the major intact PC (34:2), m/z 758.6. Ten other monoisotopic phosphocholines were found in tears. A peak at 703.3 Da was assigned as a sphingomyelin. Four lysophosphatidylcholines (m/z 490-540) accounted for about 80% of the total integrated ion count. The [M+H](+) compound, m/z 496.3, accounted for 60% of the signal intensity. Only the tear lipocalin-bearing fractions showed phosphocholines (104 ng/mL). Although the intact phospholipids bound to tear lipocalin corresponded precisely in mass and relative signal intensity to that found in tears, we did not identify phosphocholines between m/z 490 and 540 in any of the gel-filtration fractions. Phospholipids, predominantly lysophospholipids, are present in tears. The higher mass intact PCs in tears are native ligands of tear lipocalin.

  9. IETI – Isogeometric Tearing and Interconnecting

    PubMed Central

    Kleiss, Stefan K.; Pechstein, Clemens; Jüttler, Bert; Tomar, Satyendra

    2012-01-01

    Finite Element Tearing and Interconnecting (FETI) methods are a powerful approach to designing solvers for large-scale problems in computational mechanics. The numerical simulation problem is subdivided into a number of independent sub-problems, which are then coupled in appropriate ways. NURBS- (Non-Uniform Rational B-spline) based isogeometric analysis (IGA) applied to complex geometries requires to represent the computational domain as a collection of several NURBS geometries. Since there is a natural decomposition of the computational domain into several subdomains, NURBS-based IGA is particularly well suited for using FETI methods. This paper proposes the new IsogEometric Tearing and Interconnecting (IETI) method, which combines the advanced solver design of FETI with the exact geometry representation of IGA. We describe the IETI framework for two classes of simple model problems (Poisson and linearized elasticity) and discuss the coupling of the subdomains along interfaces (both for matching interfaces and for interfaces with T-joints, i.e. hanging nodes). Special attention is paid to the construction of a suitable preconditioner for the iterative linear solver used for the interface problem. We report several computational experiments to demonstrate the performance of the proposed IETI method. PMID:24511167

  10. ITER Baseline Scenario with ECCD Applied to Neoclassical Tearing Modes in DIII-D

    NASA Astrophysics Data System (ADS)

    Welander, A. G.; La Haye, R. J.; Lohr, J. M.; Humphreys, D. A.; Prater, R.; Paz-Soldan, C.; Kolemen, E.; Turco, F.; Olofsson, E.

    2015-11-01

    The neoclassical tearing mode (NTM) is a magnetic island that can occur on flux surfaces where the safety factor q is a rational number. Both m/n=3/2 and 2/1 NTM's degrade confinement, and the 2/1 mode often locks to the wall and disrupts the plasma. An NTM can be suppressed by depositing electron cyclotron current drive (ECCD) on the q-surface by injecting microwave beams into the plasma from gyrotrons. Recent DIII-D experiments have studied the application of ECCD/ECRH in the ITER Baseline Scenario. The power required from the gyrotrons can be significant enough to impact the fusion gain, Q in ITER. However, if gyrotron power could be minimized or turned off in ITER when not needed, this impact would be small. In fact, tearing-stable operation at low torque has been achieved previously in DIII-D without EC power. A vision for NTM control in ITER will be described together with results obtained from simulations and experiments in DIII-D under ITER like conditions. Work supported by the US DOE under DE-FC02-04ER54698, DE-AC02-09CH11466, DE-FG02-04ER54761.

  11. A numerical simulation of magnetic reconnection and radiative cooling in line-tied current sheets

    NASA Technical Reports Server (NTRS)

    Forbes, T. G.; Malherbe, J. M.

    1991-01-01

    Radiative MHD equations are used for an optically thin plasma to carry out a numerical experiment related to the formation of 'postflare' loops. The numerical experiment starts with a current sheet that is in mechanical and thermal equilibrium but is unstable to both tearing-mode and thermal-condensation instabilities. The current sheet is line-tied at one end to a photospheric-like boundary and evolves asymmetrically. The effects of thermal conduction, resistivity variation, and gravity are ignored. In general, reconnection in the nonlinear stage of the tearing-mode instability can strongly affect the onset of condensations unless the radiative-cooling time scale is much smaller than the tearing-mode time scale. When the ambient plasma is less than 0.2, the reconnection enters a regime where the outflow from the reconnection region is supermagnetosonic with respect to the fast-mode wave speed. In the supermagnetosonic regime the most rapidly condensing regions occur downstream of a fast-mode shock that forms where the outflow impinges on closed loops attached to the photospheric-like boundary. A similar shock-induced condensation might occur during the formation of 'postflare' loops.

  12. Current/Pressure Profile Effects on Tearing Mode Stability in DIII-D Hybrid Discharges

    NASA Astrophysics Data System (ADS)

    Kim, K.; Park, J. M.; Murakami, M.; La Haye, R. J.; Na, Yong-Su

    2015-11-01

    It is important to understand the onset threshold and the evolution of tearing modes (TMs) for developing a high-performance steady state fusion reactor. As initial and basic comparisons to determine TM onset, the measured plasma profiles (such as temperature, density, rotation) were compared with the calculated current profiles between a pair of discharges with/without n=1 mode based on the database for DIII-D hybrid plasmas. The profiles were not much different, but the details were analyzed to determine their characteristics, especially near the rational surface. The tearing stability index calculated from PEST3, Δ' tends to increase rapidly just before the n=1 mode onset for these cases. The modeled equilibrium with varying pressure or current profiles parametrically based on the reference discharge is reconstructed for checking the onset dependency on Δ' or neoclassical effects such as bootstrap current. Simulations of TMs with the modeled equilibrium using resistive MHD codes will also be presented and compared with experiments to determine the sensibility for predicting TM onset. Work supported by US DOE under DE-FC02-04ER54698 and DE-AC52-07NA27344.

  13. Non-contrast magnetic resonance imaging for diagnosing shoulder injuries.

    PubMed

    Arnold, Heino

    2012-12-01

    To compare preoperative non-contrast magnetic resonance imaging (MRI) with arthroscopy findings in diagnosing labral and rotator cuff tears. 86 men and 60 women aged 21 to 70 (mean, 52) years underwent non-contrast MRI before arthroscopic operations on the glenohumeral joint. Slices were made in a transverse, parasagittal, and paracoronar orientation. The sequences used were T2- and proton-weighted for paracoronar imaging, T1- and T2-weighted for transverse and parasagittal imaging, and T2-weigthed sequences with fat suppression and short tau inversion recovery sequences. MRI was evaluated with the surgeon to eliminate interobserver bias. Arthroscopic surgery was performed by a single surgeon. If a labral or rotator cuff tear was found, surgery was performed using corkscrew anchors. For full thickness rotator cuff tears, MRI and arthroscopy detected them in 76 and 82 patients, respectively. One such tear found by MRI could not be confirmed by arthroscopy. MRI missed 4 subscapularis and 3 supraspinatus tears. The sensitivity and specificity of MRI in diagnosing full thickness rotator cuff tears were 0.90 and 0.91, respectively. For labral tears, MRI and arthroscopy detected them in 16 and 31 patients, respectively. One anterior labral tear detected by MRI could not be verified by arthroscopy. All 16 labral tears detected by MRI were Bankart type-I tears (of the anterior glenoid) except for one superior labral tear from anterior to posterior (SLAP tear). All 13 SLAP tears (10 type 2 and 3 type 3) except for one could be found by arthroscopy only. The sensitivity and specificity of MRI in diagnosing labral tears were 0.52 and 0.89, respectively. Non-contrast MRI is reliable only for diagnosing full thickness rotator cuff tears and anterior labral tears. Direct or indirect contrast enhancement is recommended for more differentiation. Special scan orientation is necessary for SLAP tears.

  14. Tear-Film Evaporation Rate from Simultaneous Ocular-Surface Temperature and Tear-Breakup Area.

    PubMed

    Dursch, Thomas J; Li, Wing; Taraz, Baseem; Lin, Meng C; Radke, Clayton J

    2018-01-01

    A corneal heat-transfer model is presented to quantify simultaneous measurements of fluorescein tear-breakup area (TBA) and ocular-surface temperature (OST). By accounting for disruption of the tear-film lipid layer (TFLL), we report evaporation rates through lipid-covered tear. The modified heat-transfer model provides new insights into evaporative dry eye. A quantitative analysis is presented to assess human aqueous tear evaporation rate (TER) through intact TFLLs from simultaneous in vivo measurement of time-dependent infrared OST and fluorescein TBA. We interpret simultaneous OST and TBA measurements using an extended heat-transfer model. We hypothesize that TBAs are ineffectively insulated by the TFLL and therefore exhibit higher TER than does that for a well-insulting TFLL-covered tear. As time proceeds, TBAs increase in number and size, thereby increasing the cornea area-averaged TER and decreasing OST. Tear-breakup areas were assessed from image analysis of fluorescein tear-film-breakup video recordings and are included in the heat-transfer description of OST. Model-predicted OSTs agree well with clinical experiments. Percent reductions in TER of lipid-covered tear range from 50 to 95% of that for pure water, in good agreement with literature. The physical picture of noninsulating or ruptured TFLL spots followed by enhanced evaporation from underlying cooler tear-film ruptures is consistent with the evaporative-driven mechanism for local tear rupture. A quantitative analysis is presented of in vivo TER from simultaneous clinical measurement of transient OST and TBA. The new heat-transfer model accounts for increased TER through expanding TBAs. Tear evaporation rate varies strongly across the cornea because lipid is effectively missing over tear-rupture troughs. The result is local faster evaporation compared with nonruptured, thick lipid-covered tear. Evaporative-driven tear-film ruptures deepen to a thickness where fluorescein quenching commences and local salinity rises to uncomfortable levels. Mitigation of tear-film rupture may therefore reduce dry eye-related symptoms.

  15. The Fate of Meniscus Tears Left in situ at the time of Anterior Cruciate Ligament Reconstruction: A 6-year Follow-up Study from the MOON Cohort

    PubMed Central

    Duchman, Kyle R.; Westermann, Robert W.; Spindler, Kurt P.; Reinke, Emily K.; Huston, Laura J.; Amendola, Annunziato; Wolf, Brian R.

    2016-01-01

    Background The management of meniscus tears identified at the time of primary ACL reconstruction is highly variable and includes repair, meniscectomy, and non-treatment. Hypothesis/Purpose The purpose of this study is to determine the reoperation rate for meniscus tears left untreated at the time of ACL reconstruction with minimum follow-up of 6 years. We hypothesize that small, peripheral tears identified at the time of ACL reconstruction managed with “no treatment” will have successful clinical outcomes. Study Design Retrospective study of a prospective cohort; Level of Evidence, 3 Methods Patients with meniscus tears left untreated at the time of primary ACL reconstruction were identified from a multicenter study group with minimum 6-year follow-up. Patient, tear, and reoperation data were obtained for analysis. Need for reoperation was used as the primary endpoint, with analysis performed to determine patient and tear characteristics associated with reoperation. Results There were 194 patients with 208 meniscus tears (71 medial; 137 lateral) left in situ without treatment with complete follow-up for analysis. Of these, 97.8% of lateral and 94.4% of medial untreated tears required no reoperation. Sixteen tears (7.7%) left in situ without treatment underwent subsequent reoperation: 9 tears (4.3%) underwent reoperation in the setting of revision ACL reconstruction and 7 tears (3.4%) underwent reoperation for isolated meniscus pathology. Patient age was significantly lower in patients requiring reoperation, while tears measuring ≥ 10 mm more frequently required reoperation. Conclusions Lateral and medial meniscus tears left in situ at the time of ACL reconstruction did not require reoperation at minimum 6-year follow-up for 97.8% and 94.4% of tears, respectively. These findings reemphasize the low reoperation rate following non-treatment of small, peripheral lateral meniscus tears while noting less predictable results for medial meniscus tears left without treatment. PMID:26430058

  16. Posterior meniscus root tears: associated pathologies to assist as diagnostic tools.

    PubMed

    Matheny, Lauren M; Ockuly, Andrew C; Steadman, J Richard; LaPrade, Robert F

    2015-10-01

    The purpose of this study was to investigate associated pathologies identified at arthroscopy in patients with meniscus root tears. This study was Institutional Review Board approved. All patients who underwent arthroscopic knee surgery where a complete meniscus root tear was identified were included in this study. Concurrent ligament tears and articular cartilage changes ≥Outerbridge grade 2 were recorded and stored in a data registry. Fifty patients (28 males, 22 females) [mean age = 36.5 years (range 17.1-68.1 years)] who were diagnosed with a medial or lateral meniscus root tear at arthroscopy were included in this study out of 673 arthroscopic surgeries (prevalence 7.4 %). Twenty-three (46 %) patients had a medial meniscus root tear, 26 (52 %) patients had a lateral meniscus root tear and one (2 %) patient had both. Thirty-four per cent of patients (n = 17) underwent partial meniscectomy, while 60 % (n = 31) underwent suture repair. During arthroscopy, 60 % (n = 30) of patients were diagnosed with an anterior cruciate ligament (ACL) tear. Patients with lateral meniscus root tears were 10.3 times (95 % CI 2.6-42.5) more likely to have ACL tears than patients with medial meniscus root tears (p = 0.012). Patients who had medial meniscus root tears were 5.8 times (95 % CI 1.6-20.5) more likely to have chondral defects than patients who had lateral meniscus root tears (p = 0.044). In this study, patients' preoperative functional scores and activity levels were low. Patients with lateral meniscal root tears were more likely to have an ACL tear. Patients with medial meniscal root tears were more likely to have an knee articular cartilage defect with an Outerbridge grade 2 or higher chondral defect. This study confirms the importance of comprehensive assessment of concurrent injuries to properly diagnose meniscus root tears. IV.

  17. The Fate of Meniscus Tears Left In Situ at the Time of Anterior Cruciate Ligament Reconstruction: A 6-Year Follow-up Study From the MOON Cohort.

    PubMed

    Duchman, Kyle R; Westermann, Robert W; Spindler, Kurt P; Reinke, Emily K; Huston, Laura J; Amendola, Annunziato; Wolf, Brian R

    2015-11-01

    The management of meniscus tears identified at the time of primary anterior cruciate ligament (ACL) reconstruction is highly variable and includes repair, meniscectomy, and nontreatment. The purpose of this study was to determine the reoperation rate for meniscus tears left untreated at the time of ACL reconstruction with a minimum follow-up of 6 years. The hypothesis was that small peripheral tears identified at the time of ACL reconstruction managed with "no treatment" would have successful clinical outcomes. Cohort study; Level of evidence, 3. Patients with meniscus tears left untreated at the time of primary ACL reconstruction were identified from a multicenter study group with a minimum 6-year follow-up. Patient, tear, and reoperation data were obtained for analysis. The need for reoperation was used as the primary endpoint, with analysis performed to determine patient and tear characteristics associated with reoperation. There were 194 patients with 208 meniscus tears (71 medial, 137 lateral) left in situ without treatment with a complete follow-up for analysis. Of these, 97.8% of lateral and 94.4% of medial untreated tears required no reoperation. Sixteen tears (7.7%) left in situ without treatment underwent subsequent reoperation: 9 tears (4.3%) underwent reoperation in the setting of revision ACL reconstruction, and 7 tears (3.4%) underwent reoperation for an isolated meniscus injury. The patient age was significantly lower in patients requiring reoperation, while tears measuring ≥10 mm more frequently required reoperation. Lateral and medial meniscus tears left in situ at the time of ACL reconstruction did not require reoperation at a minimum 6-year follow-up for 97.8% and 94.4% of tears, respectively. These findings re-emphasize the low reoperation rate after the nontreatment of small, peripheral lateral meniscus tears while noting less predictable results for medial meniscus tears left without treatment. © 2015 The Author(s).

  18. Tear Film Osmolarity in Subjects with Acute Allergic Rhinoconjunctivitis

    PubMed Central

    NITODA, EIRINI; LAVARIS, ANASTASIOS; LAIOS, KONSTANTINOS; ANDROUDI, SOPHIA; KALOGEROPOULOS, CHRIS D; TSATSOS, MICHAEL; DAMASKOS, CHRISTOS; GARMPIS, NIKOLAOS; MOSCHOS, MARILITA M

    2018-01-01

    Background/Aim: Acute allergic rhinoconjuctivitis is the most common form of ocular allergies. The pathogenetic mechanisms are based on an immunoglobulin E (IgE)-mediated hypersensitivity reaction. On the other hand, tear osmolarity has been suggested to be an index of ocular surface damage and inflammation. These data were the motive to investigate the levels of tear osmolarity in subjects with acute allergic rhinoconjuctivitis, before and after administration of artificial tears. Patients and Methods: Forty-five subjects with acute allergic rhinoconjuctivitis were randomly divided into three groups, based on the type of artificial tears that they received: Group A (Thera tears), Group B (Wet therapy) and Group C (Tears Naturale free). The eye drops were administered six times a day for 60 days and all subjects underwent grading of subjective symptoms and clinical examination at baseline and at the end of the treatment. Results: The diagnosis of severe eye disease, which was based on ocular surface disease index (OSDI; Allergan, Inc, Irvine, CA, USA) and tear osmolarity values, concerned all patients at baseline. Although the administration of artificial tears significantly ameliorated the symptoms and the ocular variables in all groups, the results were better in the first group. Tear osmolarity was strongly and negatively correlated with tear film breakup time (BUT) and Schirmer I test at 2 months. Contrariwise, symptoms were eliminated, when tear osmolarity was decreased. Conclusion: Acute allergic rhinoconjuctivitis is characterized by tear hyperosmolarity, which can be rehabilitated with the administration of hypotonic artificial tears. PMID:29475928

  19. Effect of controlled adverse chamber environment exposure on tear functions in silicon hydrogel and hydrogel soft contact lens wearers.

    PubMed

    Kojima, Takashi; Matsumoto, Yukihiro; Ibrahim, Osama M A; Wakamatsu, Tais Hitomi; Uchino, Miki; Fukagawa, Kazumi; Ogawa, Junko; Dogru, Murat; Negishi, Kazuno; Tsubota, Kazuo

    2011-11-11

    To prospectively evaluate the effect of controlled adverse chamber environment (CACE) exposure on tear function, including tear osmolarity, in subjects wearing narafilcon A versus those wearing etafilcon A soft contact lens (SCL). Thirty-one healthy subjects with no history of contact lens wear (13 women, 18 men; average age, 30.5 ± 6.5 years) were randomly divided into age- and sex-matched groups (15 subjects wearing narafilcon A SCL; 16 subjects wearing etafilcon A SCL) and entered a CACE for 20 minutes. All subjects underwent tear osmolarity, tear evaporation rate, strip meniscometry, tear film breakup time, fluorescein vital staining, and functional visual acuity measurement before and after exposure to the controlled adverse chamber. The mean blink rate increased with significant deteriorations in the mean symptom VAS scores, mean tear osmolarity, tear evaporation rate, strip meniscometry score, and tear stability with CACE exposure along with a decrease in visual maintenance ratio in functional visual acuity testing in etafilcon A wearers. The mean symptom VAS scores, mean tear evaporation rate, tear stability, blink rates, and visual maintenance ratios did not change significantly in narafilcon A wearers after CACE exposure. This study suggested marked tear instability, higher tear osmolarity, and increased tear evaporation with marked dry eye and visual symptomatology in nonadapted hydrogel SCL wearers, suggesting that silicone hydrogel SCLs may be suitable for persons who live and work in cool, low-humidity, and windy environments, as tested in this study.

  20. Tear analysis in contact lens wearers.

    PubMed Central

    Farris, R L

    1985-01-01

    Tear analysis in contact lens wearers was compared with tear analysis in aphakics without contact lens wear and normal phakic patients. Subjects were divided into five groups: group 1, aphakic without contact lens; group 2, phakic with daily-wear hard contact lens; group 3, phakic with daily-wear soft contact lens; group 4, phakic with extended-wear soft contact lens; and group 5, aphakic with extended-wear soft contact lens. The experimental groups were compared with age- and sex-matched control groups for statistical analysis of tear variables by means of the Student's t-test. The variables measured were tear osmolarity, tear albumin, and lysozyme and lactoferrin concentrations in basal and reflex tears. Highly significant elevations of tear osmolarity were found in aphakic subjects without contact lenses. Less significant differences in tear osmolarity were found in phakic subjects with hard daily-wear lenses or with extended-wear soft lenses. Tear albumin, lysozyme, and lactoferrin in basal and reflex tears were not significantly different in the different groups of contact lens wearers or in the group of aphakic subjects without contact lenses compared with their control groups. Individual variations in tear albumin, lysozyme, and lactoferrin appeared to be responsible for the inability to demonstrate significant differences in tear composition in association with the wearing of different types of contact lenses. Older and aphakic patients demonstrated a tendency to have increased concentrations of proteins in the tears compared with younger, phakic contact lens wearers and normal controls without contact lenses. PMID:3914131

  1. Reconnection and interchange instability in the near magnetotail

    DOE PAGES

    Birn, Joachim; Liu, Yi -Hsin; Daughton, William; ...

    2015-07-16

    This paper provides insights into the possible coupling between reconnection and interchange/ballooning in the magnetotail related to substorms and flow bursts. The results presented are largely based on recent simulations of magnetotail dynamics, exploring onset and progression of reconnection. 2.5-dimensional particle-in-cell (PIC) simulations with different tail deformation demonstrate a clear boundary between stable and unstable cases depending on the amount of deformation, explored up to the real proton/electron mass ratio. The evolution prior to onset, as well as the evolution of stable cases, are governed by the conservation of integral flux tube entropy S as imposed in ideal MHD, maintainingmore » a monotonic increase with distance downtail. This suggests that ballooning instability in the tail should not be expected prior to the onset of tearing and reconnection. 3-D MHD simulations confirm this conclusion, showing no indication of ballooning prior to reconnection, if the initial state is ballooning stable. The simulation also shows that, after imposing resistivity necessary to initiate reconnection, the reconnection rate and energy release initially remain slow. However, when S becomes reduced from plasmoid ejection and lobe reconnection, forming a negative slope in S as a function of distance from Earth, the reconnection rate and energy release increase drastically. The latter condition has been shown to be necessary for ballooning/interchange instability, and the cross-tail structures that develop subsequently in the MHD simulation are consistent with such modes. The simulations support a concept in which tail activity is initiated by tearing instability but significantly enhanced by the interaction with ballooning/interchange enabled by plasmoid loss and lobe reconnection.« less

  2. Behavioral and neural responses to infant and adult tears: The impact of maternal love withdrawal.

    PubMed

    Riem, Madelon M E; van IJzendoorn, Marinus H; De Carli, Pietro; Vingerhoets, Ad J J M; Bakermans-Kranenburg, Marian J

    2017-09-01

    The current study examined behavioral and neural responses to infant and adult tears, taking into account childhood experiences with parental love-withdrawal. With functional MRI (fMRI), we measured neural reactivity to pictures of infants and adults with and without tears on their faces in nulliparous women with varying childhood experiences of maternal use of love withdrawal. Behavioral responses to infant and adult tears were measured with an approach-avoidance task. We found that individuals with experiences of love withdrawal showed less amygdala and insula reactivity to adult tears, but love withdrawal did not affect amygdala and insula reactivity to infant tears. During the approach-avoidance task, individuals responded faster to adult tears in the approach condition compared with the avoidance condition, indicating that adult tears facilitate approach behavior. Individuals responded faster to infant tears than to adult tears, regardless of approach or avoidance condition. Our findings suggest that infant tears are highly salient and may, therefore, overrule the effects of contextual and personal characteristics that influence the perception of adult crying. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  3. [Rotator cuff tear athropathy prevalence].

    PubMed

    Guerra-Soriano, F; Encalada-Díaz, M I; Ruiz-Suárez, M; Valero-González, F S

    2017-01-01

    Glenohumeral arthritis secondary to massive rotator cuff tear presents with a superior displacement and femoralization of the humeral head with coracoacromial arch acetabularization. The purpose of this study was to establish prevalence of rotator cuff tear artropathy (CTA) at our institution. Four hundred electronic records were reviewed from which we identified 136 patients with rotator cuff tears. A second group was composed with patients with massive cuff tears that were analized and staged by the Seebauer cuff tear arthropathy classification. Thirty four patients with massive rotator cuff tears were identified, 8 male and 26 female (age 60.1 ± 10.26 years). Massive rotator cuff tear prevalence was 25%. CTA prevalence found in the rotator cuff group was 19 and 76% in the massive cuff tears group. Patients were staged according to the classification with 32% in stage 1a, 11% 1b, 32% 2a and 0% 2b. CTA prevalence in patients with rotator cuff tears and massive cuff tears is higher than the one reported in American population. We consider that a revision of the Seebauer classification to be appropriate to determine its reliability.

  4. Characteristics of radial tears in the posterior horn of the medial meniscus compared to horizontal tears.

    PubMed

    Choi, Chul-Jun; Choi, Yun-Jin; Song, In-Bum; Choi, Chong-Hyuk

    2011-06-01

    The clinical and radiologic features of radial tears of the medial meniscus posterior horn were compared with those of horizontal tears. From January 2007 to December 2008, 387 consecutive cases of medial meniscal tears were treated arthroscopically. Among these, 91 were radial tears in the medial meniscus posterior horn, and 95 were horizontal tears in the posterior segment of the medial meniscus. The patients' data (age, gender, duration of symptom, body mass index, and injury history), radiographic findings (Kellgren and Lawrence score, posterior tibial slope, and femorotibial angle), and chondral lesions were recorded. The patient factors of age, gender, and body mass index were related to radial tears of the medial meniscus posterior horn. Radial tears were significantly correlated with Kellgren and Lawrence score, varus alignment, posterior tibial slope, and severity of the chondral lesion. Radial tears of the medial meniscus posterior horn are a unique clinical entity that are associated with older age, females and obesity, and are strongly associated with an increased incidence and severity of cartilage degeneration compared to horizontal tears.

  5. Skin fragility syndrome in a cat with feline infectious peritonitis and hepatic lipidosis.

    PubMed

    Trotman, Tara K; Mauldin, Elizabeth; Hoffmann, Vickie; Del Piero, Fabio; Hess, Rebecka S

    2007-10-01

    A 6-year-old spayed female domestic shorthair cat with a 3-week history of inappetence, weight loss, and hiding was examined. A palpable abdominal fluid wave, dehydration, and a small tear on the left flank were noted during initial examination. When the cat was gently restrained for blood sampling, the skin on the dorsal neck tore, leaving a 15 cm x 7 cm flap of skin. Clinicopathological abnormalities included nonregenerative anaemia, hypoalbuminaemia, increased globulin concentration, and mildly elevated aspartate aminotransferase and alkaline phosphatase activities. Abdominal fluid was viscous and had a total protein of 5.3 g dL(-1) with 316 cells microL(-1), consistent with a modified transudate. Cytology of the abdominal fluid revealed 86% nondegenerate neutrophils, 13% macrophages, and 1% small lymphocytes. Histopathological evaluation and indirect immunohistochemistry confirmed a diagnosis of feline infectious peritonitis, hepatic lipidosis and feline skin fragility syndrome. Feline skin fragility syndrome has not previously been reported in association with feline infectious peritonitis (FIP). Its inclusion as a clinical sign associated with FIP may facilitate a diagnosis.

  6. The Coracohumeral Distance in Shoulders With Traumatic and Degenerative Subscapularis Tendon Tears.

    PubMed

    Balke, Maurice; Banerjee, Marc; Greshake, Oliver; Hoeher, Juergen; Bouillon, Bertil; Liem, Dennis

    2016-01-01

    A reduced coracohumeral distance (CHD) is thought to be responsible for subcoracoid impingement. This only accounts for degenerative tendon tears. In traumatic tears, the subcoracoid space should be normal. The CHD in patients with traumatic subscapularis tendon tears is larger than that in patients with degenerative tears and does not differ from patients with an intact subscapularis tendon. Cohort study; Level of evidence, 3. A total of 83 patients with arthroscopically certified subscapularis tendon tears were included in the study. Forty-four patients had degenerative causes (group 1), and 39 had traumatic causes (group 2). The control group consisted of 20 patients with traumatic supraspinatus tendon tears and arthroscopically proven, intact subscapularis tendons (group 3). On preoperative axial magnetic resonance imaging, the distance between the CHD was measured, and the values of the 3 groups were compared using the t test. The mean (±SD) CHD in patients with degenerative subscapularis tendon tears was 8.6 ± 2.0 mm (range, 4.0-13.2 mm) and was significantly (P = .0003) smaller than that in patients with traumatic tears (10.2 ± 2.0 mm; range, 6.6-16.2 mm) or controls (10.4 ± 1.8 mm; range, 6.8-14.0 mm). The CHD of controls and patients with traumatic tears did not differ significantly (P = .7875). A CHD of less than 6 mm only occurred in patients with degenerative subscapularis tendon tears. The hypothesis that the CHD in patients with degenerative subscapularis tendon tears is significantly smaller than that in patients with traumatic tears or intact subscapularis tendons was confirmed. The CHD in patients with traumatic tears does not differ from that in controls. A CHD of less than 6 mm only occurs in patients with degenerative subscapularis tendon tears. © 2015 The Author(s).

  7. Incidence of skin tears in the extremities among elderly patients at a long-term medical facility in Japan: A prospective cohort study.

    PubMed

    Sanada, Hiromi; Nakagami, Gojiro; Koyano, Yuiko; Iizaka, Shinji; Sugama, Junko

    2015-08-01

    There is a lack of data from cohort studies for the incidence of skin tears among an elderly population in an Asian country. We estimated the cumulative incidence of skin tear, and identify its risk factor. The present prospective cohort study was carried out at a long-term medical facility in Japan. Participants included patients (n = 368) aged 65 years or older receiving hospital care. The 3-month cumulative incidence of skin tears was estimated by identifying them using direct inspection of the extremities. In order to find the risk factors for the skin tear incidence, odds ratios and their 95% confidence intervals of skin tear development in association with the factors were estimated using logistic regression analyses. A total of 14 patients developed skin tears, and their cumulative incidence was 3.8%. No patients with skin tears developed multiple wounds on their extremities. Half of the skin tears occurred on the outside of the right forearm, and just three skin tears were found in the lower legs. Multiple logistic analyses showed that pre-existing skin tears (odds ratio 15.42, 95% confidence interval 3.53-67.43, P < 0.001) and a 6-point decrease in the total score of the Braden Scale (odds ratio 0.10, 95% confidence interval 0.01-0.83, P < 0.033) were significantly associated with skin tear development. Patients with pre-existing skin tears and a low score of the Braden Scale have a higher risk of skin tear development during 3 months. These factors could be used to identify patients requiring prevention care for skin tears. © 2014 Japan Geriatrics Society.

  8. The Relationship Between Intraoperative Tear Dimensions and Postoperative Pain in 1624 Consecutive Arthroscopic Rotator Cuff Repairs.

    PubMed

    Yeo, Daniel Y T; Walton, Judie R; Lam, Patrick; Murrell, George A C

    2017-03-01

    Rotator cuff repair often results in significant pain postoperatively, the cause of which is undetermined. Purpose/Hypothesis: The aim of this study was to evaluate the relationship between rotator cuff tear area and postoperative pain in patients who had undergone arthroscopic rotator cuff repair. We hypothesized that larger tears would be more painful because of elevated repair tension at 1 week postoperatively but that smaller tears would be more painful because of a greater healing response, especially from 6 weeks postoperatively. Cohort study; Level of evidence, 3. A total of 1624 patients who underwent arthroscopic rotator cuff repair were included in this study. Exclusion criteria were moderate to severe osteoarthritis, isolated subscapularis repair, calcific tendinitis, synthetic patch repair, revision surgery, and retears on ultrasound at 6 months after surgery. Rotator cuff tears were subdivided into groups based on the tear size and retear rate found for each group. A modified L'Insalata questionnaire was given before surgery and at 1 week, 6 weeks, 3 months, and 6 months after surgery. Pearson and Spearman correlation coefficient tests were performed between rotator cuff tear areas and pain scores. Intraoperative rotator cuff tear areas did not correlate with pain scores preoperatively or at 1 week after surgery. A smaller tear area was associated with more frequent and severe pain with overhead activities, at rest, and during sleep as well as a poorer perceived overall shoulder condition at 6 weeks, 3 months, and 6 months after repair ( r = 0.11-0.23, P < .0001). Patients who were younger, had partial-thickness tears, and had occupational injuries experienced more pain postoperatively ( r = 0.10-0.28, P < .0001). Larger tears did not have more pain at 1 week after surgery. The retear rate was 7% in tears <2 cm 2 but reached 44% in tears >8 cm 2 . There were fewer retears with smaller tears, but they were more painful than large tears postoperatively from 6 weeks to 6 months after surgery. Smaller tears may heal more vigorously, causing more pain. Patients with smaller tears experienced more pain after rotator cuff repair compared with patients with larger tears. These findings are contrary to previous ideas about tear size and postoperative pain. Healing is likely a determinant of postoperative pain.

  9. Biomechanical comparison of single-row arthroscopic rotator cuff repair technique versus transosseous repair technique.

    PubMed

    Tocci, Stephen L; Tashjian, Robert Z; Leventhal, Evan; Spenciner, David B; Green, Andrew; Fleming, Braden C

    2008-01-01

    This study determined the effect of tear size on gap formation of single-row simple-suture arthroscopic rotator cuff repair (ARCR) vs transosseous Mason-Allen suture open RCR (ORCR) in 13 pairs of human cadaveric shoulders. A massive tear was created in 6 pairs and a large tear in 7. Repairs were cyclically tested in low-load and high-load conditions, with no significant difference in gap formation. Under low-load, gapping was greater in massive tears. Under high-load, there was a trend toward increased gap with ARCR for large tears. All repairs of massive tears failed in high-load. Gapping was greater posteriorly in massive tears for both techniques. Gap formation of a modeled RCR depends upon the tear size. ARCR of larger tears may have higher failure rates than ORCR, and the posterior aspect appears to be the site of maximum gapping. Specific attention should be directed toward maximizing initial fixation of larger rotator cuff tears, especially at the posterior aspect.

  10. Ultrasound determination of rotator cuff tear repairability

    PubMed Central

    Tse, Andrew K; Lam, Patrick H; Walton, Judie R; Hackett, Lisa

    2015-01-01

    Background Rotator cuff repair aims to reattach the torn tendon to the greater tuberosity footprint with suture anchors. The present study aimed to assess the diagnostic accuracy of ultrasound in predicting rotator cuff tear repairability and to assess which sonographic and pre-operative features are strongest in predicting repairability. Methods The study was a retrospective analysis of measurements made prospectively in a cohort of 373 patients who had ultrasounds of their shoulder and underwent rotator cuff repair. Measurements of rotator cuff tear size and muscle atrophy were made pre-operatively by ultrasound to enable prediction of rotator cuff repairability. Tears were classified following ultrasound as repairable or irreparable, and were correlated with intra-operative repairability. Results Ultrasound assessment of rotator cuff tear repairability has a sensitivity of 86% (p < 0.0001) and a specificity of 67% (p < 0.0001). The strongest predictors of rotator cuff repairability were tear size (p < 0.001) and age (p = 0.004). Sonographic assessments of tear size ≥4 cm2 or anteroposterior tear length ≥25 mm indicated an irreparable rotator cuff tear. Conclusions Ultrasound assessment is accurate in predicting rotator cuff tear repairability. Tear size or anteroposterior tear length and age were the best predictors of repairability. PMID:27582996

  11. Tear Film Osmolarity in Subjects with Acute Allergic Rhinoconjunctivitis.

    PubMed

    Nitoda, Eirini; Lavaris, Anastasios; Laios, Konstantinos; Androudi, Sophia; Kalogeropoulos, Chris D; Tsatsos, Michael; Damaskos, Christos; Garmpis, Nikolaos; Moschos, Marilita M

    2018-01-01

    Acute allergic rhinoconjuctivitis is the most common form of ocular allergies. The pathogenetic mechanisms are based on an immunoglobulin E (IgE)-mediated hypersensitivity reaction. On the other hand, tear osmolarity has been suggested to be an index of ocular surface damage and inflammation. These data were the motive to investigate the levels of tear osmolarity in subjects with acute allergic rhinoconjuctivitis, before and after administration of artificial tears. Forty-five subjects with acute allergic rhinoconjuctivitis were randomly divided into three groups, based on the type of artificial tears that they received: Group A (Thera tears), Group B (Wet therapy) and Group C (Tears Naturale free). The eye drops were administered six times a day for 60 days and all subjects underwent grading of subjective symptoms and clinical examination at baseline and at the end of the treatment. The diagnosis of severe eye disease, which was based on ocular surface disease index (OSDI; Allergan, Inc, Irvine, CA, USA) and tear osmolarity values, concerned all patients at baseline. Although the administration of artificial tears significantly ameliorated the symptoms and the ocular variables in all groups, the results were better in the first group. Tear osmolarity was strongly and negatively correlated with tear film breakup time (BUT) and Schirmer I test at 2 months. Contrariwise, symptoms were eliminated, when tear osmolarity was decreased. Acute allergic rhinoconjuctivitis is characterized by tear hyperosmolarity, which can be rehabilitated with the administration of hypotonic artificial tears. Copyright© 2018, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.

  12. Evaporation-driven instability of the precorneal tear film.

    PubMed

    Peng, Cheng-Chun; Cerretani, Colin; Braun, Richard J; Radke, C J

    2014-04-01

    Tear-film instability is widely believed to be a signature of eye health. When an interblink is prolonged, randomly distributed ruptures occur in the tear film. "Black spots" and/or "black streaks" appear in 15 to 40 s for normal individuals. For people who suffer from dry eye, tear-film breakup time (BUT) is typically less than a few seconds. To date, however, there is no satisfactory quantitative explanation for the origin of tear rupture. Recently, it was proposed that tear-film breakup is related to locally high evaporative thinning. A spatial variation in the thickness of the tear-film lipid layer (TFLL) may lead to locally elevated evaporation and subsequent tear-film breakup. We examine the local-evaporation-driven tear-film-rupture hypothesis in a one-dimensional (1-D) model for the evolution of a thin aqueous tear film overriding the cornea subject to locally elevated evaporation at its anterior surface and osmotic water influx at its posterior surface. Evaporation rate depends on mass transfer both through the coating lipid layer and through ambient air. We establish that evaporation-driven tear-film breakup can occur under normal conditions but only for higher aqueous evaporation rates. Predicted roles of environmental conditions, such as wind speed and relative humidity, on tear-film stability agree with clinical observations. More importantly, locally elevated evaporation leads to hyperosmolar spots in the tear film and, hence, vulnerability to epithelial irritation. In addition to evaporation rate, tear-film instability depends on the strength of healing flow from the neighboring region outside the breakup region, which is determined by the surface tension at the tear-film surface and by the repulsive thin-film disjoining pressure. This study provides a physically consistent and quantitative explanation for the formation of black streaks and spots in the human tear film during an interblink. Copyright © 2013 Elsevier B.V. All rights reserved.

  13. 49 CFR 178.1070 - Tear test.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 3 2013-10-01 2013-10-01 false Tear test. 178.1070 Section 178.1070... Containers § 178.1070 Tear test. (a) General. The tear test must be conducted for the qualification of all of Flexible Bulk Containers design types. (b) Special preparation for the tear test. Flexible Bulk Container...

  14. Human tears contain a chemosignal.

    PubMed

    Gelstein, Shani; Yeshurun, Yaara; Rozenkrantz, Liron; Shushan, Sagit; Frumin, Idan; Roth, Yehudah; Sobel, Noam

    2011-01-14

    Emotional tearing is a poorly understood behavior that is considered uniquely human. In mice, tears serve as a chemosignal. We therefore hypothesized that human tears may similarly serve a chemosignaling function. We found that merely sniffing negative-emotion-related odorless tears obtained from women donors induced reductions in sexual appeal attributed by men to pictures of women's faces. Moreover, after sniffing such tears, men experienced reduced self-rated sexual arousal, reduced physiological measures of arousal, and reduced levels of testosterone. Finally, functional magnetic resonance imaging revealed that sniffing women's tears selectively reduced activity in brain substrates of sexual arousal in men.

  15. Tear thinning time and topical anesthesia as assessed using the HIRCAL grid and the NCCA.

    PubMed

    Blades, K J; Murphy, P J; Patel, S

    1999-03-01

    The literature contains conflicting reports of the effects of topical anesthetics on tear film stability, with some consensus that unpreserved topical anesthetics are less likely to reduce tear film stability than preserved preparations. This experiment investigated the effect of unpreserved 0.4% benoxinate hydrochloride on tear thinning time (TTT), in parallel with "real time" corneal sensitivity assessment. Tear film stability was assessed (HIRCAL grid) in parallel with real time assessment of the pharmacological activity (NCCA) of unpreserved 0.4% benoxinate hydrochloride in normal eyes. The anesthetic used did not significantly affect tear film stability. This finding is in agreement with previous investigators. Unpreserved 0.4% benoxinate hydrochloride could be used to facilitate tear film stability assessment. The experimental protocol used could also be applied to investigate the temporal relationship between anesthesia and tear film stability with preserved topical anesthetics that have been found to decrease tear film stability.

  16. Tear dysfunction and the cornea: LXVIII Edward Jackson Memorial Lecture.

    PubMed

    Pflugfelder, Stephen C

    2011-12-01

    To describe the cause and consequence of tear dysfunction-related corneal disease. Perspective on effects of tear dysfunction on the cornea. Evidence is presented on the effects of tear dysfunction on corneal morphology, function, and health, as well as efficacy of therapies for tear dysfunction-related corneal disease. Tear dysfunction is a prevalent eye disease and the most frequent cause for superficial corneal epithelial disease that results in corneal barrier disruption, an irregular optical surface, light scattering, optical aberrations, and exposure and sensitization of pain-sensing nerve endings (nociceptors). Tear dysfunction-related corneal disease causes irritation and visual symptoms such as photophobia and blurred and fluctuating vision that may decrease quality of life. Dysfunction of 1 or more components of the lacrimal functional unit results in changes in tear composition, including elevated osmolarity and increased concentrations of matrix metalloproteinases, inflammatory cytokines, and chemokines. These tear compositional changes promote disruption of tight junctions, alter differentiation, and accelerate death of corneal epithelial cells. Corneal epithelial disease resulting from tear dysfunction causes eye irritation and decreases visual function. Clinical and basic research has improved understanding of the pathogenesis of tear dysfunction-related corneal epithelial disease, as well as treatment outcomes. Copyright © 2011 Elsevier Inc. All rights reserved.

  17. Increased Tear Film Osmolarity in Systemic Lupus Erythematosus.

    PubMed

    Duru, Necati; Altinkaynak, Hasan; Uysal, Betul Seher; Duru, Zeynep; Can, Mehmet Erol; Erten, Sukran; Yuksel, Nilay; Kalkan Akcay, Emine

    2017-01-01

    To evaluate tear film osmolarity in patients with systemic lupus erythematosus (SLE). A total of 55 eyes from 55 patients with SLE and 47 eyes from 47 age- and gender-matched healthy individuals were included in this study. Tear film osmolarity was evaluated with a lab-on-a-chip technique (TearLab; TearLab Corporation, San Diego, CA) in SLE patients in comparison with healthy individuals, and results were correlated to clinically available diagnostic tests for dry eye, such as tear film break-up time (BUT), Schirmer's test, and Ocular Surface Disease Index (OSDI). The mean tear film osmolarity in the SLE patients and healthy individuals was 306.02 ± 13.27 mOsm/L and 300.74 ± 9.11 mOsm/L, respectively, which made for a statistically significant difference (p = 0.020). In the SLE group, tear film osmolarity was negatively correlated with the Schirmer's test score and the BUT value (r = -0.295 p = 0.029 and r = 0.347 p = 0.009, respectively), whereas tear film osmolarity was not correlated with OSDI score (r = -0.182 p = 0.183). This study revealed that tear film hyperosmolarity and abnormal tear film function are associated with SLE.

  18. Emotional tears facilitate the recognition of sadness and the perceived need for social support.

    PubMed

    Balsters, Martijn J H; Krahmer, Emiel J; Swerts, Marc G J; Vingerhoets, Ad J J M

    2013-02-12

    The tearing effect refers to the relevance of tears as an important visual cue adding meaning to human facial expression. However, little is known about how people process these visual cues and their mediating role in terms of emotion perception and person judgment. We therefore conducted two experiments in which we measured the influence of tears on the identification of sadness and the perceived need for social support at an early perceptional level. In two experiments (1 and 2), participants were exposed to sad and neutral faces. In both experiments, the face stimuli were presented for 50 milliseconds. In experiment 1, tears were digitally added to sad faces in one condition. Participants demonstrated a significant faster recognition of sad faces with tears compared to those without tears. In experiment 2, tears were added to neutral faces as well. Participants had to indicate to what extent the displayed individuals were in need of social support. Study participants reported a greater perceived need for social support to both sad and neutral faces with tears than to those without tears. This study thus demonstrated that emotional tears serve as important visual cues at an early (pre-attentive) level.

  19. Anatomical significance of a posterior horn of medial meniscus: the relationship between its radial tear and cartilage degradation of joint surface.

    PubMed

    Kan, Akinori; Oshida, Midori; Oshida, Shigemi; Imada, Masato; Nakagawa, Takumi; Okinaga, Shuji

    2010-01-12

    Traumatic injury and surgical meniscectomy of a medial meniscus are known to cause subsequent knee osteoarthritis. However, the difference in the prevalence of osteoarthritis caused by the individual type of the medial meniscal tear has not been elucidated. The aim of this study was to investigate what type of tear is predominantly responsible for the degradation of articular cartilage in the medial compartment of knee joints. Five hundred and forty eight cadaveric knees (290 male and 258 female) were registered in this study. The average age of cadavers at death was 78.8 years old (range: 52-103 years). The knees were macroscopically examined and their medial menisci were classified into four groups according to types of tears: "no tear", "radial tear of posterior horn", "other types of tear" and "worn-out meniscus" groups. The severity of cartilage degradation in their medial compartment of knee joints was evaluated using the international cartilage repair society (ICRS) grading system. We statistically compared the ICRS grades among the groups using Mann-Whitney U test. The knees were assigned into the four groups: 416 "no tear" knees, 51 "radial tear of posterior horn" knees, 71 "other types of tear" knees, and 10 "worn-out meniscus" knees. The knees with substantial meniscal tears showed the severer ICRS grades of cartilage degradation than those without meniscal tears. In addition, the ICRS grades were significantly severer in the "radial tear of posterior horn" group than in the "other types of tear" group, suggesting that the radial tear of posterior horn in the medial meniscus is one of the risk factors for cartilage degradation of joint surface. We have clarified the relationship between the radial tear of posterior horn in the medial meniscus and the severer grade of cartilage degradation. This study indicates that the efforts should be made to restore the anatomical role of the posterior horn in keeping the hoop strain, when patients' physical activity levels are high and the tear pattern is simple enough to be securely sutured.

  20. Development of risk reduction behavioral counseling for Ebola virus disease survivors enrolled in the Sierra Leone Ebola Virus Persistence Study, 2015-2016.

    PubMed

    Abad, Neetu; Malik, Tasneem; Ariyarajah, Archchun; Ongpin, Patricia; Hogben, Matthew; McDonald, Suzanna L R; Marrinan, Jaclyn; Massaquoi, Thomas; Thorson, Anna; Ervin, Elizabeth; Bernstein, Kyle; Ross, Christine; Liu, William J; Kroeger, Karen; Durski, Kara N; Broutet, Nathalie; Knust, Barbara; Deen, Gibrilla F

    2017-09-01

    During the 2014-2016 West Africa Ebola Virus Disease (EVD) epidemic, the public health community had concerns that sexual transmission of the Ebola virus (EBOV) from EVD survivors was a risk, due to EBOV persistence in body fluids of EVD survivors, particularly semen. The Sierra Leone Ebola Virus Persistence Study was initiated to investigate this risk by assessing EBOV persistence in numerous body fluids of EVD survivors and providing risk reduction counseling based on test results for semen, vaginal fluid, menstrual blood, urine, rectal fluid, sweat, tears, saliva, and breast milk. This publication describes implementation of the counseling protocol and the key lessons learned. The Ebola Virus Persistence Risk Reduction Behavioral Counseling Protocol was developed from a framework used to prevent transmission of HIV and other sexually transmitted infections. The framework helped to identify barriers to risk reduction and facilitated the development of a personalized risk-reduction plan, particularly around condom use and abstinence. Pre-test and post-test counseling sessions included risk reduction guidance, and post-test counseling was based on the participants' individual test results. The behavioral counseling protocol enabled study staff to translate the study's body fluid test results into individualized information for study participants. The Ebola Virus Persistence Risk Reduction Behavioral Counseling Protocol provided guidance to mitigate the risk of EBOV transmission from EVD survivors. It has since been shared with and adapted by other EVD survivor body fluid testing programs and studies in Ebola-affected countries.

  1. The Location of Anterior Cruciate Ligament Tears: A Prevalence Study Using Magnetic Resonance Imaging

    PubMed Central

    van der List, Jelle P.; Mintz, Douglas N.; DiFelice, Gregory S.

    2017-01-01

    Background: Over the past decade, there has been a resurgence of interest in anterior cruciate ligament (ACL) preservation. Proximal and distal avulsion tears have been treated with arthroscopic primary repair, while augmented repair, remnant tensioning, primary repair with biological scaffold, and remnant preservation have been proposed for different types of midsubstance tears. Currently, the incidence of these different tear types is unknown. Purpose: To propose a magnetic resonance imaging (MRI) classification system for different tear types based on clinical relevance and to assess the distribution of these different ACL tear types. Study Design: Case series; Level of evidence, 4. Methods: A retrospective search in an institutional radiographic database was performed for patients who underwent knee MRI at our institution between June 2014 and June 2016. Patients younger than 18 years and those with reports of chronic tears, partial tears, multiligamentous injuries, were excluded. Tear types were graded as proximal avulsion (distal remnant length >90% of total ligament length, type I), proximal (75%-90%, type II), midsubstance (25%-75%, type III), distal (10%-25%, type IV), and distal avulsion (<10%, type V). An orthopaedic surgeon, a radiologist, and a research fellow graded the tear type on 30 MRIs to determine reliability, and the research fellow graded all MRIs. Inter- and intraobserver reliability were measured using kappa statistics. Results: A total of 353 patients (57% male; mean age, 37.1 years; range, 18.1-81.2 years) were included. Interobserver reliability was 0.670 (95% confidence interval, 0.505-0.836), and intraobserver reliability ranged from 0.741 to 0.934. Incidence of type I tears was 16%, type II tears 27%, type III tears 52%, type IV tears 1%, and type V tears 3% (2.5% with bony avulsion). Type I tears were more common in patients older than 35 years compared with those younger than 35 years (23% vs 8%; P < .001). Conclusion: This classification system was reliable in assessing tear location in acute ACL injuries. Type I tears were seen in 16%, type II in 27%, and type III in 52% of patients in our cohort. These data suggest that there may be greater potential application for ACL preservation techniques. PMID:28680889

  2. Can the optimum artificial tear treatment for dry eye disease be predicted from presenting signs and symptoms?

    PubMed

    Essa, Laika; Laughton, Deborah; Wolffsohn, James S

    2018-02-01

    To assess dry eye treatment with four preservative-free dry eye artificial tear treatments to facilitate evidence-based prescribing. A randomised, single masked crossover trial of Clinitas Soothe, Hyabak, Tears Again and TheraTears artificial tears was conducted on 50 symptomatic dry eye patients, aged 60.8±14.2years. At baseline and after trialling each treatment for 4 weeks, signs and symptoms were assessed using the Ocular Surface Disease Index (OSDI), non-invasive tear break-up time, fluorescein tear break-up time, tear meniscus height (TMH), Phenol Red test, lid-parallel conjunctival folds (LIPCOF), ocular surface staining, and lipid layer grading and osmolarity (baseline visit only). OSDI (p=0.002), LIPCOF (p=0.014) and conjunctival staining (p<0.001) significantly improved from baseline, however, the impact of each dry eye treatment on ocular symptoms and signs was similar. Clinitas Soothe and Hyabak were preferred by 34%/30% of participants, but only subjective comparison with the other drops influenced this choice. TheraTears was preferred (by 24%) by those with a lower baseline tear volume (p=0.01) and Tears Again (by 12%) by those with a thinner baseline lipid layer (p=0.04). The treatment that afforded the greatest improvement in clinical signs did not consistently match each individual's preferred treatment. If prescribed to a general dry eye population, the artificial tears performed similarly, improving symptoms and conjunctival signs. However, osmolarity balanced artificial tears were the preferred treatment in individuals with low baseline tear volume and lipisomal spray for individuals with a baseline lipid layer deficiency. Copyright © 2017 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  3. Does partial tear repair of adjacent tendons improve the outcome of supraspinatus tendonfull-thickness tear reinsertion?

    PubMed

    Nich, C; Dhiaf, N; Di Schino, M; Augereau, B

    2014-11-01

    Partial tearing of the infraspinatus and/or subscapularis tendon(s) is frequently associated with supraspinatus full-thickness tears. However, limited data regarding its influence on supraspinatus surgical repair is available. Our aim was to assess the functional and anatomical outcomes of open repair of supraspinatus full-thickness tears combined with adjacent partial tearing, comparatively to a control. We retrospectively identified 22 patients (22 shoulders) with a partial tear, most of them being a delamination tear, of the infraspinatus and/or subscapularis tendons associated with a complete detachment of the supraspinatus tendon. Twenty-seven patients (27 shoulders) treated for an isolated complete detachment of the supraspinatus tendon by open repair served as controls. The mean age was 58 years. A proximalized trans-osseous reinsertion of the supraspinatus tendon was combined with a curettage-closure of the delamination tear. Patients were evaluated with standardized MRI at last follow-up. At a mean of 75-month follow-up, the presence of a partial tear of either infraspinatus or subscapularis, or both, did not influence function and healing rates of supraspinatus tendon repair. Conversely to the control, when a retear occurred, the functional score tended to worsen. Preoperatively, fatty muscular degeneration was more pronounced when a partial tear was present. Fatty degeneration worsened regardless of repair healing. Open reinsertion of a supraspinatus full-thickness tear associated with a thorough treatment of partial tear of adjacent tendons led to optimal functional and anatomical mid term outcomes. Our results suggest the presence of a partial tear of adjacent tendons could be associated with poorer function in case of supraspinatus tendon re-rupture. Level III case-control study. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  4. Fluid-structure interaction simulations of deformable structures with non-linear thin shell elements

    NASA Astrophysics Data System (ADS)

    Asgharzadeh, Hafez; Hedayat, Mohammadali; Borazjani, Iman; Scientific Computing; Biofluids Laboratory Team

    2017-11-01

    Large deformation of structures in a fluid is simulated using a strongly coupled partitioned fluid-structure interaction (FSI) approach which is stabilized with under-relaxation and the Aitken acceleration technique. The fluid is simulated using a recently developed implicit Newton-Krylov method with a novel analytical Jacobian. Structures are simulated using a triangular thin-shell finite element formulation, which considers only translational degrees of freedom. The thin-shell method is developed on the top of a previously implemented membrane finite element formulation. A sharp interface immersed boundary method is used to handle structures in the fluid domain. The developed FSI framework is validated against two three-dimensional experiments: (1) a flexible aquatic vegetation in the fluid and (2) a heaving flexible panel in fluid. Furthermore, the developed FSI framework is used to simulate tissue heart valves, which involve large deformations and non-linear material properties. This work was supported by American Heart Association (AHA) Grant 13SDG17220022 and the Center of Computational Research (CCR) of University at Buffalo.

  5. Involvement of synovial matrix degradation and angiogenesis in oxidative stress-exposed degenerative rotator cuff tears with osteoarthritis.

    PubMed

    Noh, Kyu-Cheol; Park, Sin-Hye; Yang, Cheol Jung; Lee, Geun Woo; Kim, Min Ki; Kang, Young-Hee

    2018-01-01

    Shoulder osteoarthritis is a gradual wearing of the articular cartilage concomitant with degenerative rotator cuff tears (RCTs). This pathologic disorder is related to inflammation, oxidative stress, and angiogenesis. Degenerative alterations may prompt production of cytokines and angiogenesis-related proteins, evoking rotator cuff diseases. This study tested the hypothesis that oxidative stress-responsive mediators can influence joint inflammation of patients with RCT. Twelve healthy RCT patients not suffering shoulder osteoarthritis were categorized as the control group, and 24 patients were allocated to 2 RCT groups (RCTP1 and RCTP2), according to severity of RCT and glenohumeral arthritis. Cytokines, growth factors, and angiogenic biomarkers in synovial fluids, blood, platelet-rich plasma (PRP), and tendon tissues were analyzed with enzyme-linked immunosorbent assay, immunoblotting, and collagen zymography. Induction of interleukin 8, tumor necrosis factor α, and interleukin 1β was considerably elevated in synovial fluids of RCTP groups (P = .0398, P = .0428, P = .0828, respectively). The joint inflammation highly enhanced insulin-like growth factor 1 and transforming growth factor β1 (TGF-β1) in the synovial fluids and serum. Angiogenesis-related angiopoietin (Ang) 1 and 2, Tie-2, and hypoxia-inducible factor 1α were upregulated in reactive oxygen species-exposed RCTP synovium (P < .05). The production of matrix metalloproteinase 1 markedly increased in synovial fluids of the RCTP group (P = .043), whereas tissue collagen type I expression diminished with reduction of connective tissue growth factor expression (P = .032). Although the secretion of platelet-derived growth factor AB and vascular endothelial growth factor was marginal in the circulation (P = .714, P = .335), platelet-derived growth factor AB, TGF-β1, Ang-1, and matrix metalloproteinase 1 were enriched in PRP of the RCTP group (P < .001, P = .002, P = .0389, respectively). Synovial matrix degradation and oxidative stress-triggered angiogenesis may be involved in inducing RCT with joint inflammation. TGF-β1, Ang-1, and Ang-2 are the major components to repair RCT and to alleviate joint inflammation in PRP therapy. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  6. 49 CFR 178.818 - Tear test.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 3 2013-10-01 2013-10-01 false Tear test. 178.818 Section 178.818 Transportation... Tear test. (a) General. The tear test must be conducted for the qualification of all flexible IBC design types. (b) Special preparation for the tear test. The flexible IBC must be filled to not less than...

  7. 49 CFR 178.818 - Tear test.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Tear test. 178.818 Section 178.818 Transportation... § 178.818 Tear test. (a) General. The tear test must be conducted for the qualification of all flexible IBC design types. (b) Special preparation for the tear test. The flexible IBC must be filled to not...

  8. Artificial tears potpourri: a literature review

    PubMed Central

    Moshirfar, Majid; Pierson, Kasey; Hanamaikai, Kamalani; Santiago-Caban, Luis; Muthappan, Valliammai; Passi, Samuel F

    2014-01-01

    Numerous brands and types of artificial tears are available on the market for the treatment of dysfunctional tear syndrome. Past literature has focused on comparing the components of these products on patient’s clinical improvement. The wide array of products on the market presents challenges to both clinicians and patients when trying to choose between available tear replacement therapies. Different formulations affect patients based on etiology and severity of disease. In order to provide an unbiased comparison between available tear replacement therapies, we conducted a literature review of existing studies and National Institutes of Health clinical trials on commercially available, brand name artificial tears. Outcomes evaluated in each study, as well as the percent of patients showing clinical and symptomatic improvement, were analyzed. Fifty-one studies evaluating different brands of artificial tears, and their efficacy were identified. Out of the 51 studies, 18 were comparison studies testing brand name artificial tears directly against each other. Nearly all formulations of artificial tears provided significant benefit to patients with dysfunctional tear syndrome, but some proved superior to others. From the study data, a recommended treatment flowchart was derived. PMID:25114502

  9. Numerical MHD study for plasmoid instability in uniform resistivity

    NASA Astrophysics Data System (ADS)

    Shimizu, Tohru; Kondoh, Koji; Zenitani, Seiji

    2017-11-01

    The plasmoid instability (PI) caused in uniform resistivity is numerically studied with a MHD numerical code of HLLD scheme. It is shown that the PI observed in numerical studies may often include numerical (non-physical) tearing instability caused by the numerical dissipations. By increasing the numerical resolutions, the numerical tearing instability gradually disappears and the physical tearing instability remains. Hence, the convergence of the numerical results is observed. Note that the reconnection rate observed in the numerical tearing instability can be higher than that of the physical tearing instability. On the other hand, regardless of the numerical and physical tearing instabilities, the tearing instability can be classified into symmetric and asymmetric tearing instability. The symmetric tearing instability tends to occur when the thinning of current sheet is stopped by the physical or numerical dissipations, often resulting in the drastic changes in plasmoid chain's structure and its activity. In this paper, by eliminating the numerical tearing instability, we could not specify the critical Lundquist number Sc beyond which PI is fully developed. It suggests that Sc does not exist, at least around S = 105.

  10. [Abnormal of tear lipid layer and recent advances in clinical study of dry eye].

    PubMed

    Xiao, Xin-Ye; Liu, Zu-Guo

    2012-03-01

    Dry eye is a common disease in the ophthalmological clinic, which is related to the dysfunction of tear film. The tear film is composed of lipid layer, aqueous layer and mucin layer (or lipid layer, aqueous/mucin layer). The lipid of the outmost layer derived from Meibomian gland and distributed on the tear film after blinking can decrease the evaporation and stabilize the tear film. The thickness, quality, and distribution of lipid layer are impaired in many dry eye patients, hence restoring the physiological function of lipid layer may be crucial for the treatment of this kind of dry eye. The lipid artificial tears manifest great effects on increasing lipid layer thickness, stabilizing tear film, improving Meibomian gland dysfunction, and promoting tear film distribution.

  11. A novel remaining tendon preserving repair technique leads to improved outcomes in special rotator cuff tear patterns.

    PubMed

    Jeon, Yoon Sang; Kim, Rag Gyu; Shin, Sang-Jin

    2018-05-16

    The purpose of this study was to identify the tear pattern that could be anatomically repaired by preserving the remaining tendon on footprint and evaluate clinical outcomes of patients who underwent remaining tendon preserving cuff repair. Of 523 patients with full-thickness rotator cuff tears who underwent arthroscopic repair, 41 (7.8%) patients had repairable rotator cuff tear while preserving the remaining tendon. Among them, 31 patients were followed-up for more than 2 years, including 26 patients with posterior L-shaped tear and 5 patients with transtendinous tear patterns. Clinical outcomes were evaluated using ASES and Constant score, SANE score for patient satisfaction, and VAS for pain. MRI was taken for tendon integrity 6 months postoperatively. Of the 31 patients, 11 (35.5%) had previous injury history before rotator cuff tear, including 7 (26.9%) of the 26 patients with posterior L-shaped tear and 4 (80%) of the 5 patients with transtendinous tear. The average size of preoperative cuff tear was 17.8 ± 6.8 mm in anterior-to-posterior direction and 15.2 ± 5.1 mm in medial-to-lateral direction. ASES and Constant score, SANE score, and VAS for pain were significantly (p < 0.001) improved after remaining tendon preserving rotator cuff repair. Rotator cuff tendons of 22(84.6%) patients with posterior L-shaped tear and 4(80%) patients with transtendinous tear patterns were healed. Patients who underwent rotator cuff repair with preservation of the remaining tendon on the footprint obtained satisfactory functional outcomes. Rotator cuff tears in patients who had posterior L-shaped tear extending between supraspinatus and infraspinatus tendons or transtendinous tear pattern with substantial remaining tendon could be repaired using remaining tendon preserving repair technique. Anatomic reduction of torn cuff tendon without undue tension could be achieved using the remaining tendon preserving repair technique.

  12. [Diagnostic value of MRI for posterior root tear of medial and lateral meniscus].

    PubMed

    Qian, Yue-Nan; Liu, Fang; Dong, Yi-Long; Cai, Chun-Yuan

    2018-03-25

    To explore diagnostic value of MRI on posterior root tear of medial and lateral meniscus. From January 2012 to January 2016, clinical data of 43 patients with meniscal posterior root tear confirmed by arthroscopy were retrospective analyzed, including 25 males and 18 females, aged from 27 to 69 years old with an average age of(42.5±8.3)years old;27 cases on the right side and 16 cases on the left side. MRI examinations of 43 patients with tear of posterior meniscus root confirmed by knee arthroscopies were retrospectively reviewed. MRI images were double-blinded, independently, retrospectively scored by two imaging physicians. Sensitivity, specificity and accuracy of MRI diagnosis of lateral and medial meniscus posterior root tear were calculated, and knee ligament injury and meniscal dislocation were calculated. Forty-three of 143 patients were diagnosed with meniscus posterior root tears by arthroscopy, including 19 patients with lateral tears and 24 patients with medial tears. The sensitivity, specificity and accuracy in diagnosis of posterior medial meniscus root tears for doctor A were 91.67%, 86.6% and 83.9% respectively, and for doctor B were 87.5%, 87.4% and 87.4%, 19 patients with medial meniscal protrusion and 2 patients with anterior cruciate ligament tear. The sensitivity, specificity and accuracy in diagnosis of posterior lateral meniscus root tears for doctor A were 73.7%, 79.9% and 79% respectively, and for doctor B were 78.9%, 82.3% and 82.5%, 4 patients with lateral meniscus herniation and 16 patients with cruciate ligament tear. Kappa statistics for posterior medial meniscus root tears and posterior lateral meniscus root tears were 0.84 and 0.72. MRI could effectively demonstrate imaging features of medial and lateral meniscal root tear and its accompanying signs. It could provide the basis for preoperative diagnosis of clinicians, and be worthy to be popularized. Copyright© 2018 by the China Journal of Orthopaedics and Traumatology Press.

  13. Blepharitis

    MedlinePlus

    ... tear film can result in excess tearing or dry eye. Because tears are necessary to keep the cornea ... redness of the eye, blurred vision, frothy tears, dry eye, or crusting of the eyelashes on awakening. Treatment ...

  14. Rotator cuff problems

    MedlinePlus

    ... smooth layer) lining these tendons. A rotator cuff tear occurs when one of the tendons is torn ... Poor posture over many years Aging Rotator cuff tears TEARS Rotator cuff tears may occur in two ...

  15. Tearing relaxation and the globalization of transport in field-reversed configurations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Steinhauer, Loren; Barnes, D. C.

    2009-09-15

    Tearing instability of field-reversed configurations (FRC) is investigated using the method of neighboring equilibria. It is shown that the conducting wall position in experiment lies very close to the location needed for tearing stability. This strongly suggests that vigorous but benign tearing modes, acting globally, are the engine of continual self-organization in FRCs, i.e., tearing relaxation. It also explains the ''profile consistency'' and anomalous loss rate of magnetic flux. In effect, tearing globalizes the effect of edge-driven transport.

  16. Cemental tear: To know what we have neglected in dental practice.

    PubMed

    Jeng, Po-Yuan; Luzi, Arlinda Luzi; Pitarch, Rocio Marco; Chang, Mei-Chi; Wu, Yu-Hsueh; Jeng, Jiiang-Huei

    2018-04-01

    Cemental tear is a special kind of root surface fracture, contributing to periodontal and periapical breakdown. However, it is a challenge for doctors to diagnose, resulting in delayed or improper treatment. We reviewed the predisposing factors, location, radiographic/clinical characteristics, diagnosis and treatments of cemental tears. From the literature, patients with cemental tear were mainly males, over 60 year-old. Possible predisposing factors include gender, age, tooth type, traumatic occlusal force and vital teeth. Cemental tears were common in upper and lower anterior teeth, single or multiple, and can be present in cervical, middle and apical third of roots. Morphology of cemental tears can be either piece-shaped or U-shaped. Clinically, cemental tear shows a unitary periodontal pocket and signs/symptoms mimicking localized periodontitis, apical periodontitis and vertical root fractures. Treatment of cemental tears include scaling, root planning, root canal treatment, periodontal/periapical surgery, guided tissue regeneration, bone grafting, and intentional replantation. Recurrence of cemental tear is possible especially when the fracture involves root apex. Extraction is recommended for teeth with poor prognosis. In conclusion, cemental tears can involve both periodontal and periapical area. Dentists should understand the predisposing factors and clinical features of cemental tears for early diagnosis/treatment to prevent bone loss/tooth extraction. Copyright © 2017. Published by Elsevier B.V.

  17. Two types of peak emotional responses to music: The psychophysiology of chills and tears

    PubMed Central

    Mori, Kazuma; Iwanaga, Makoto

    2017-01-01

    People sometimes experience a strong emotional response to artworks. Previous studies have demonstrated that the peak emotional experience of chills (goose bumps or shivers) when listening to music involves psychophysiological arousal and a rewarding effect. However, many aspects of peak emotion are still not understood. The current research takes a new perspective of peak emotional response of tears (weeping, lump in the throat). A psychophysiological experiment showed that self-reported chills increased electrodermal activity and subjective arousal whereas tears produced slow respiration during heartbeat acceleration, although both chills and tears induced pleasure and deep breathing. A song that induced chills was perceived as being both happy and sad whereas a song that induced tears was perceived as sad. A tear-eliciting song was perceived as calmer than a chill-eliciting song. These results show that tears involve pleasure from sadness and that they are psychophysiologically calming; thus, psychophysiological responses permit the distinction between chills and tears. Because tears may have a cathartic effect, the functional significance of chills and tears seems to be different. We believe that the distinction of two types of peak emotions is theoretically relevant and further study of tears would contribute to more understanding of human peak emotional response. PMID:28387335

  18. Factors predicting rotator cuff retears: an analysis of 1000 consecutive rotator cuff repairs.

    PubMed

    Le, Brian T N; Wu, Xiao L; Lam, Patrick H; Murrell, George A C

    2014-05-01

    The rate of retears after rotator cuff repair varies from 11% to 94%. A retear is associated with poorer subjective and objective clinical outcomes than intact repair. This study was designed to determine which preoperative and/or intraoperative factors held the greatest association with retears after arthroscopic rotator cuff repair. Cohort study; Level of evidence, 3. This study retrospectively evaluated 1000 consecutive patients who had undergone a primary rotator cuff repair by a single surgeon using an arthroscopic inverted-mattress knotless technique and who had undergone an ultrasound evaluation 6 months after surgery to assess repair integrity. Exclusion criteria included previous rotator cuff repair on the same shoulder, incomplete repair, and repair using a synthetic polytetrafluoroethylene patch. All patients had completed the modified L'Insalata Questionnaire and underwent a clinical examination before surgery. Measurements of tear size, tear thickness, associated shoulder injury, tissue quality, and tendon mobility were recorded intraoperatively. The overall retear rate at 6 months after surgery was 17%. Retears occurred in 27% of full-thickness tears and 5% of partial-thickness tears (P < .0001). The best independent predictors of retears were anteroposterior tear length (correlation coefficient r = 0.41, P < .0001), tear size area (r = 0.40, P < .0001), mediolateral tear length (r = 0.34, P < .0001), tear thickness (r = 0.29, P < .0001), age at surgery (r = 0.27, P < .0001), and operative time (r = 0.18, P < .0001). These factors produced a predictive model for retears: logit P = (0.039 × age at surgery in years) + (0.027 × tear thickness in %) + (1 × anteroposterior tear length in cm) + (0.76 × mediolateral tear length in cm) - (0.17 × tear size area in cm(2)) + (0.018 × operative time in minutes) -9.7. Logit P can be transformed into P, which is the chance of retears at 6 months after surgery. A rotator cuff retear is a multifactorial process with no single preoperative or intraoperative factor being overwhelmingly predictive of it. Nevertheless, rotator cuff tear size (tear dimensions, tear size area, and tear thickness) showed stronger associations with retears at 6 months after surgery than did measures of tissue quality and concomitant shoulder injuries.

  19. Prevalence of Skin Tears in Elderly Patients: A Retrospective Chart Review of Incidence Reports in 6 Long-term Care Facilities.

    PubMed

    Hawk, Joyce; Shannon, Mary

    2018-04-01

    The incidence and prevalence of skin tears in long-term care (LTC) facilities has not been well established. To ascertain the point prevalence of reported skin tears, a retrospective review of incident reports was performed in 6 LTC facilities in western Pennsylvania from November 1, 2016 through December 31, 2016. Report data, including resident age; gender; mobility limitations; skin tear location, number, and cause (if known); occurrence time (7 am to 3 pm, 3 pm to 11 pm, or 11 pm to 7 am nursing shift); and history of previous skin tears, were abstracted. All data were entered into a statistical analysis program and analyzed using descriptive statistics. Period prevalence was used to determine prevalence rate; an independent t test was used to compare the presence of skin tears between genders. Differences between location and cause of skin tears were evaluated using a multinomial test of related proportions. A test of proportions was used to evaluate skin tear occurrence time (nursing shift) differences. The overall point prevalence rate was 9% (N = 1253 residents) ranging from 6 to 28 skin tears per facility. The average age of residents with a skin tear (n = 119) was 83.5 years. The majority (111, 93%) had mobility limitations. Falls accounted for 38 skin tears (31.9%), followed by propelling in a wheelchair (18, 15.1%; X2 =7.14; P = .008). Forearm skin tears (37, 31.1%) occurred significantly more frequently than lower leg skin tears (19, 16%; P = .016). Significantly more skin tears occurred during the 7 am to 3 pm shift (47, 39.5%) and 3 pm to 11 pm shift (49, 41.2%) than during the 11 pm to 7 am shift (23, 19.3%; X2 = 5.78; P <.01). The results of this study confirm skin tears are a significant problem among elderly residents in LTC, especially because the reported rate is likely lower than the actual rate. Research to further elucidate the incidence and prevalence of skin tears and associated risk factors is needed to help develop evidence-based risk assessment, classification systems, treatment guidelines, and preventive measures.

  20. Aspergillus flavus induced alterations in tear protein profile reveal pathogen-induced host response to fungal infection.

    PubMed

    Kandhavelu, Jeyalakshmi; Demonte, Naveen Luke; Namperumalsamy, Venkatesh Prajna; Prajna, Lalitha; Thangavel, Chitra; Jayapal, Jeya Maheshwari; Kuppamuthu, Dharmalingam

    2017-01-30

    Aspergillus flavus and Fusarium sp. are primary causative agents of keratitis that results in corneal tissue damage leading to vision loss particularly in individuals from the tropical parts of the world. Proteins in the tear film collected from control and keratitis patients was profiled and compared. A total of 1873 proteins from control and 1400 proteins from patient tear were identified by mass spectrometry. While 847 proteins were found to be glycosylated in the patient tear, only 726 were glycosylated in control tear. And, some of the tear proteins showed alterations in their glycosylation pattern after infection. Complement system proteins, proteins specific for neutrophil extracellular traps and proteins involved in would healing were found only in the patient tear. The presence of these innate immune system proteins in the tear film of patients supports the previous data indicating the involvement of neutrophil and complement pathways in antifungal defense. High levels of wound healing proteins in keratitis patient tear implied activation of tissue repair during infection. The early appearance of the host defense proteins and wound healing response indicates that tear proteins could be used as an early marker system for monitoring the progression of pathogenesis. Identification of negative regulators of the above defense pathways in keratitis tear indicates an intricate balance of pro and anti-defense mechanisms operating in fungal infection of the eye. Tear proteins from control and mycotic keratitis patients were separated into glycoproteins and non-glycosylated proteins and then identified by mass spectrometry. Tear proteins from keratitis patients showed alteration in the glycosylation pattern indicating the alteration of glycosylation machinery due to infection. Neutrophil extracellular traps specific proteins, complement pathway proteins, as well as wound healing proteins, were found only in patient tear showing the activation of antifungal defense in the patient tear. Negative regulators of these defense pathways were also found in patient tear indicating a fine balance between pathogen clearance and host tissue destruction during fungal infection depending upon the individual specific host - pathogen interaction. This understanding could be used to predict the progression and outcome of infection. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Arthroscopic repair of partial-thickness and small full-thickness rotator cuff tears: tendon quality as a prognostic factor for repair integrity.

    PubMed

    Chung, Seok Won; Kim, Jae Yoon; Yoon, Jong Pil; Lyu, Seong Hwa; Rhee, Sung Min; Oh, Se Bong

    2015-03-01

    The healing failure rate is high for partial-thickness or small full-thickness rotator cuff tears. To retrospectively evaluate and compare outcomes after arthroscopic repair of high-grade partial-thickness and small full-thickness rotator cuff tears and factors affecting rotator cuff healing. Cohort study; Level of evidence, 3. Included in the study were 55 consecutive patients (mean age, 57.9 ± 7.2 years) who underwent arthroscopic repair for high-grade partial-thickness (n = 34) and small full-thickness (n = 21) rotator cuff tears. The study patients also underwent magnetic resonance imaging (MRI) preoperatively and computed tomography arthrography (CTA) at least 6 months postoperatively, and their functional outcomes were evaluated preoperatively and at the last follow-up (>24 months). All partial-thickness tears were repaired after being converted to full-thickness tears; thus, the repair process was almost the same as for small full-thickness tears. The tendinosis of the torn tendon was graded from the MRI images using a 4-point scale, and the reliabilities were assessed. The outcomes between high-grade partial-thickness tears that were converted to small full-thickness tears and initially small full-thickness tears were compared, and factors affecting outcomes were evaluated. The inter- and intraobserver reliabilities of the tendinosis grade were good (intraclass correlation coefficient, 0.706 and 0.777, respectively). Failure to heal as determined by CTA was observed in 12 patients with a high-grade partial-thickness tear (35.3%; complete failure in 4 and partial failure in 8) and in 3 patients with a small full-thickness tear (14.3%; complete failure in 1 and partial failure in 2). The patients with high-grade partial-thickness rotator cuff tears showed a higher tendinosis grade than did those with small full-thickness tears (P = .014), and the severity of the tendinosis was related to the failure to heal (P = .037). Tears with a higher tendinosis grade showed a 7.64-times higher failure rate (95% CI, 1.43-36.04) than did those with a lower tendinosis grade (P = .013). All functional outcome scores improved after surgery (all P < .001); however, there was no difference between groups. The high-grade partial-thickness rotator cuff tears showed more severe tendinosis compared with the small full-thickness tears in this study. Contrary to previous impressions that tear size or fatty infiltration is the factor that most influences healing, tendinosis severity assessed by preoperative MRI was the only factor associated with failure to heal, given the numbers available for analysis, in patients with partial-thickness and small full-thickness rotator cuff tears. Surgeons should pay more attention to tendon quality during repair surgery or rehabilitation in smaller rotator cuff tears, especially in high-grade partial-thickness tears with severe tendinosis. © 2014 The Author(s).

  2. Stochastic Simulation of Complex Fluid Flows

    DTIC Science & Technology

    The PI has developed novel numerical algorithms and computational codes to simulate the Brownian motion of rigidparticles immersed in a viscous fluid...processes and to the design of novel nanofluid materials. Therandom Brownian motion of particles in fluid can be accounted for in fluid-structure

  3. Rotation profile flattening and toroidal flow shear reversal due to the coupling of magnetic islands in tokamaks

    DOE PAGES

    Tobias, B.; Chen, M.; Classen, I. G. J.; ...

    2016-04-15

    The electromagnetic coupling of helical modes, including those having different toroidal mode numbers, modifies the distribution of toroidal angular momentum in tokamak discharges. This can have deleterious effects on other transport channels as well as on magnetohydrodynamic (MHD) stability and disruptivity. At low levels of externally injected momentum, the coupling of core-localized modes initiates a chain of events, whereby flattening of the core rotation profile inside successive rational surfaces leads to the onset of a large m/n = 2/1 tearing mode and locked-mode disruption. Furthermore, with increased torque from neutral beam injection, neoclassical tearing modes in the core may phase-lockmore » to each other without locking to external fields or structures that are stationary in the laboratory frame. The dynamic processes observed in these cases are in general agreement with theory, and detailed diagnosis allows for momentum transport analysis to be performed, revealing a significant torque density that peaks near the 2/1 rational surface. However, as the coupled rational surfaces are brought closer together by reducing q95, additional momentum transport in excess of that required to attain a phase-locked state is sometimes observed. Rather than maintaining zero differential rotation (as is predicted to be dynamically stable by single-fluid, resistive MHD theory), these discharges develop hollow toroidal plasma fluid rotation profiles with reversed plasma flow shear in the region between the m/n = 3/2 and 2/1 islands. Additional forces expressed in this state are not readily accounted for, and therefore, analysis of these data highlights the impact of mode coupling on torque balance and the challenges associated with predicting the rotation dynamics of a fusion reactor-a key issue for ITER. Published by AIP Publishing.« less

  4. Rotation profile flattening and toroidal flow shear reversal due to the coupling of magnetic islands in tokamaks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tobias, B.; Grierson, B. A.; Okabayashi, M.

    2016-05-15

    The electromagnetic coupling of helical modes, even those having different toroidal mode numbers, modifies the distribution of toroidal angular momentum in tokamak discharges. This can have deleterious effects on other transport channels as well as on magnetohydrodynamic (MHD) stability and disruptivity. At low levels of externally injected momentum, the coupling of core-localized modes initiates a chain of events, whereby flattening of the core rotation profile inside successive rational surfaces leads to the onset of a large m/n = 2/1 tearing mode and locked-mode disruption. With increased torque from neutral beam injection, neoclassical tearing modes in the core may phase-lock to each othermore » without locking to external fields or structures that are stationary in the laboratory frame. The dynamic processes observed in these cases are in general agreement with theory, and detailed diagnosis allows for momentum transport analysis to be performed, revealing a significant torque density that peaks near the 2/1 rational surface. However, as the coupled rational surfaces are brought closer together by reducing q{sub 95}, additional momentum transport in excess of that required to attain a phase-locked state is sometimes observed. Rather than maintaining zero differential rotation (as is predicted to be dynamically stable by single-fluid, resistive MHD theory), these discharges develop hollow toroidal plasma fluid rotation profiles with reversed plasma flow shear in the region between the m/n = 3/2 and 2/1 islands. The additional forces expressed in this state are not readily accounted for, and therefore, analysis of these data highlights the impact of mode coupling on torque balance and the challenges associated with predicting the rotation dynamics of a fusion reactor—a key issue for ITER.« less

  5. A collision scheme for hybrid fluid-particle simulation of plasmas

    NASA Astrophysics Data System (ADS)

    Nguyen, Christine; Lim, Chul-Hyun; Verboncoeur, John

    2006-10-01

    Desorption phenomena at the wall of a tokamak can lead to the introduction of impurities at the edge of a thermonuclear plasma. In particular, the use of carbon as a constituent of the tokamak wall, as planned for ITER, requires the study of carbon and hydrocarbon transport in the plasma, including understanding of collisional interaction with the plasma. These collisions can result in new hydrocarbons, hydrogen, secondary electrons and so on. Computational modeling is a primary tool for studying these phenomena. XOOPIC [1] and OOPD1 are widely used computer modeling tools for the simulation of plasmas. Both are particle type codes. Particle simulation gives more kinetic information than fluid simulation, but more computation time is required. In order to reduce this disadvantage, hybrid simulation has been developed, and applied to the modeling of collisions. Present particle simulation tools such as XOOPIC and OODP1 employ a Monte Carlo model for the collisions between particle species and a neutral background gas defined by its temperature and pressure. In fluid-particle hybrid plasma models, collisions include combinations of particle and fluid interactions categorized by projectile-target pairing: particle-particle, particle-fluid, and fluid-fluid. For verification of this hybrid collision scheme, we compare simulation results to analytic solutions for classical plasma models. [1] Verboncoeur et al. Comput. Phys. Comm. 87, 199 (1995).

  6. Prevalence of triceps tendon tears on MRI of the elbow and clinical correlation.

    PubMed

    Koplas, Monica C; Schneider, Erika; Sundaram, Murali

    2011-05-01

    Triceps tendon injuries are reported to be very rare. To our knowledge, there have been no studies describing its prevalence or injury patterns on MR imaging. The purpose of this retrospective study was to determine the prevalence and patterns of triceps injuries based on a large series of consecutive MR examinations. Clinical correlation was obtained. From 801 consecutive elbow MR examinations over a 15-year period, 28 patients with 30 triceps tendon injuries were identified and graded as partial tendon tear and complete tendon tear. The patients' medical records were reviewed to determine age, gender, cause of tears, and management. The prevalence of triceps tendon injuries was 3.8%. There were 5 women and 23 men with partial or complete tears (mean age: 46.6 years; range: 2.7 to 75.1 years). The most common injury was partial tear, found in 18 patients. There were 10 patients with 12 complete tears (2 had re-torn following surgical repair). A tear was suspected in 12 out 28 (43%) patients prior to the MRI. The most common presenting symptom was pain. The most common cause was athletic injury (8 patients [29%], including weightlifting [2 patients]). Tendon tear was found to be a complication of infection in 6 patients, and in 3 patients the tears were a complication of steroid use. Thirteen tendon tears were surgically repaired (8 of these were complete tears). Triceps tendon injury is not as rare as commonly reported and may often be clinically underdiagnosed.

  7. The Changes of Tear Status after Conventional and Wavefront-Guided IntraLASIK

    PubMed Central

    Foo, Say Kiang; Kaur, Sharanjeet; Abd Manan, Faudziah; Low, Aloysius Joseph

    2011-01-01

    Background: IntraLASIK is a LASIK surgery that involved IntraLase femtosecond laser for the corneal flap creating. The objective of this research was to investigate and compare the changes in tear status at 1 and 3 months after undergoing conventional IntraLASIK with Bausch & Lomb PlanoScan (PS) algorithm, Bausch & Lomb Zyoptix Tissue Saving (ZTS) algorithm, and wavefront-guided (WG) IntraLASIK with VISX CustomVue. Methods: Tear status of 36 patients who were divided into 3 groups depending on the type of IntraLASIK they underwent (PS, n = 13; ZTS, n = 9; WG, n = 14) was evaluated. Tear status was determined by classifying the category of the thickness of pre-corneal tear lipid layer, non-invasive tear break-up time, and tear meniscus height. Repeated measures analysis of variance (ANOVA) and one way ANOVA were used for the statistical analyses. Results: The category of the thickness of tear lipid layer, non-invasive tear break up time and tear meniscus height were neither significantly changed after IntraLASIK for all groups nor showed significant difference among groups at 1 and 3 months post-IntraLASIK (P > 0.05). Blinking rate and palpebral aperture also had no significant changed after IntraLASIK. Conclusion: Both conventional (PS and ZTS) and WG IntraLASIK did not affect tear status up to 3 months post-IntraLASIK. WG IntraLASIK did not show superiority in preserving tear status 1 and 3 months post-surgery compared with conventional IntraLASIK. PMID:22135584

  8. Malnutrition is independently associated with skin tears in hospital inpatient setting-Findings of a 6-year point prevalence audit.

    PubMed

    Munro, Emma L; Hickling, Donna F; Williams, Damian M; Bell, Jack J

    2018-05-24

    Skin tears cause pain, increased length of stay, increased costs, and reduced quality of life. Minimal research reports the association between skin tears, and malnutrition using robust measures of nutritional status. This study aimed to articulate the association between malnutrition and skin tears in hospital inpatients using a yearly point prevalence of inpatients included in the Queensland Patient Safety Bedside Audit, malnutrition audits and skin tear audits conducted at a metropolitan tertiary hospital between 2010 and 2015. Patients were excluded if admitted to mental health wards or were <18 years. A total of 2197 inpatients were included, with a median age of 71 years. The overall prevalence of skin tears was 8.1%. Malnutrition prevalence was 33.5%. Univariate analysis demonstrated associations between age (P ˂ .001), body mass index (BMI) (P < .001) and malnutrition (P ˂ .001) but not gender (P = .319). Binomial logistic regression analysis modelling demonstrated that malnutrition diagnosed using the Subjective Global Assessment was independently associated with skin tear incidence (odds ratio, OR: 1.63; 95% confidence interval, CI: 1.13-2.36) and multiple skin tears (OR 2.48 [95% CI 1.37-4.50]). BMI was not independently associated with skin tears or multiple skin tears. This study demonstrated independent associations between malnutrition and skin tear prevalence and multiple skin tears. It also demonstrated the limitations of BMI as a nutritional assessment measure. © 2018 Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  9. Implementation of the full viscoresistive magnetohydrodynamic equations in a nonlinear finite element code

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Haverkort, J.W.; Dutch Institute for Fundamental Energy Research, P.O. Box 6336, 5600 HH Eindhoven; Blank, H.J. de

    Numerical simulations form an indispensable tool to understand the behavior of a hot plasma that is created inside a tokamak for providing nuclear fusion energy. Various aspects of tokamak plasmas have been successfully studied through the reduced magnetohydrodynamic (MHD) model. The need for more complete modeling through the full MHD equations is addressed here. Our computational method is presented along with measures against possible problems regarding pollution, stability, and regularity. The problem of ensuring continuity of solutions in the center of a polar grid is addressed in the context of a finite element discretization of the full MHD equations. Amore » rigorous and generally applicable solution is proposed here. Useful analytical test cases are devised to verify the correct implementation of the momentum and induction equation, the hyperdiffusive terms, and the accuracy with which highly anisotropic diffusion can be simulated. A striking observation is that highly anisotropic diffusion can be treated with the same order of accuracy as isotropic diffusion, even on non-aligned grids, as long as these grids are generated with sufficient care. This property is shown to be associated with our use of a magnetic vector potential to describe the magnetic field. Several well-known instabilities are simulated to demonstrate the capabilities of the new method. The linear growth rate of an internal kink mode and a tearing mode are benchmarked against the results of a linear MHD code. The evolution of a tearing mode and the resulting magnetic islands are simulated well into the nonlinear regime. The results are compared with predictions from the reduced MHD model. Finally, a simulation of a ballooning mode illustrates the possibility to use our method as an ideal MHD method without the need to add any physical dissipation.« less

  10. Evaluation of inter-day and inter-individual variability of tear peptide/protein profiles by MALDI-TOF MS analyses

    PubMed Central

    González, Nerea; Iloro, Ibon; Durán, Juan A.; Elortza, Félix

    2012-01-01

    Purpose To characterize the tear film peptidome and low molecular weight protein profiles of healthy control individuals, and to evaluate changes due to day-to-day and individual variation and tear collection methods, by using solid phase extraction coupled to matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) profiling. Methods The tear protein profiles of six healthy volunteers were analyzed over seven days and inter-day and inter-individual variability was evaluated. The bilaterality of tear film and the effect of tear collection methods on protein profiles were also analyzed in some of these patients. MALDI-TOF MS analyses were performed on tear samples purified by using a solid phase extraction (SPE) method based on C18 functionalized magnetic beads for peptide and low molecular weight protein enrichment, focusing spectra acquisition on the 1 to 20 kDa range. Spectra were analyzed using principal component analysis (PCA) with MultiExperiment Viewer (TMeV) software. Volunteers were examined in terms of tear production status (Schirmer I test), clinical assessment of palpebral lids and meibomian glands, and a subjective OSD questionnaire before tear collection by a glass micro-capillary. Results Analysis of peptides and proteins in the 1–20 kDa range showed no significant inter-day differences in tear samples collected from six healthy individuals during seven days of monitoring, but revealed subtle intrinsic inter-individual differences. Profile analyses of tears collected from the right and left eyes confirmed tear bilaterality in four healthy patients. The addition of physiologic serum for tear sample collection did not affect the peptide and small protein profiles with respect to the number of resolved peaks, but it did reduce the signal intensity of the peaks, and increased variability. Magnetic beads were found to be a suitable method for tear film purification for the profiling study. Conclusions No significant variability in tear peptide and protein profiles below 20 kDa was found in healthy controls over a seven day period, nor in right versus left eye profiles from the same individual. Subtle inter-individual differences can be observed upon tear profiling analysis and confirm intrinsic variability between control subjects. Addition of physiologic serum for tear collection affects the proteome and peptidome in terms of peak intensities, but not in the composition of the profiles themselves. This work shows that MALDI-TOF MS coupled with C18 magnetic beads is an effective and reproducible methodology for tear profiling studies in the clinical monitoring of patients. PMID:22736947

  11. Warm and touching tears: tearful individuals are perceived as warmer because we assume they feel moved and touched.

    PubMed

    Zickfeld, Janis H; Schubert, Thomas W

    2018-01-31

    Recent work investigated the inter-individual functions of emotional tears in depth. In one study (Van de Ven, N., Meijs, M. H. J., & Vingerhoets, A. (2017). What emotional tears convey: Tearful individuals are seen as warmer, but also as less competent. British Journal of Social Psychology, 56(1), 146-160. Https://doi.org/10.1111/bjso.12162) tearful individuals were rated as warmer, and participants expressed more intentions to approach and help such individuals. Simultaneously, tearful individuals were rated as less competent, and participants expressed less intention to work with the depicted targets. While tearful individuals were perceived as sadder, perceived sadness mediated only the effect on competence, but not on warmth. We argue that tearful individuals might be perceived as warm because they are perceived as feeling moved and touched. We ran a pre-registered extended replication of Van de Ven et al. Results replicate the warmth and helping findings, but not the competence and work effects. The increase in warmth ratings was completely mediated by perceiving feeling moved and touched. Possible functions of feeling moved and touched with regard to emotional tears are discussed.

  12. In vitro effect of a corrosive hostile ocular surface on candidate biomaterials for keratoprosthesis skirt

    PubMed Central

    Tan, Xiao Wei; Riau, Andri; Shi, Zhi Long; Tan, Anna C S; Neoh, Koon Gee; Khor, Khiam Aik; Beuerman, Roger W; Tan, Donald; Mehta, Jodhbir S

    2012-01-01

    Aim Keratoprosthesis (KPro) devices are prone to long-term corrosion and microbiological assault. The authors aimed to compare the inflammatory response and material dissolution properties of two candidate KPro skirt materials, hydroxyapatite (HA) and titania (TiO2) in a simulated in vitro cornea inflammation environment. Methods Lipopolysaccharide-stimulated cytokine secretions were evaluated with human corneal fibroblasts on both HA and TiO2. Material specimens were subjected to electrochemical and long-term incubation test with artificial tear fluid (ATF) of various acidities. Topography and surface roughness of material discs were analysed by scanning electron microscopy and atomic force microscopy. Results There were less cytokines secreted from human corneal fibroblasts seeded on TiO2 substrates as compared with HA. TiO2 was more resistant to the corrosion effect caused by acidic ATF in contrast to HA. Moreover, the elemental composition of TiO2 was more stable than HA after long-term incubation with ATF. Conclusions TiO2 is more resistant to inflammatory degradation and has a higher corrosion resistance as compared with HA, and in this regard may be a suitable material to replace HA as an osteo-odonto-keratoprosthesis skirt. This would reduce resorption rates for KPro surgery. PMID:22802307

  13. Design and evaluation of novel fast forming pilocarpine-loaded ocular hydrogels for sustained pharmacological response

    PubMed Central

    Anumolu, SivaNaga S.; Singh, Yashveer; Gao, Dayuan; Stein, Stanley; Sinko, Patrick J.

    2009-01-01

    Fast forming hydrogels prepared by crosslinking a poly(ethylene glycol) (PEG)-based copolymer containing multiple thiol (SH) groups were evaluated for the controlled ocular delivery of pilocarpine and subsequent pupillary constriction. Physical properties of the hydrogels were characterized using UV-Vis spectrophotometry, transmission electron microscopy (TEM), rheometry, and swelling kinetics. Pilocarpine loading efficiency and release properties were measured in simulated tear fluid. The hydrogel formulations exhibited high drug loading efficiency (~74%). Pilocarpine release was found to be biphasic with release half times of ~2 and 94 h, respectively, and 85–100% of the drug was released over 8-days. Pilocarpine-loaded (2% w/v) hydrogels were evaluated in a rabbit model and compared to a similar dose of drug in aqueous solution. The hydrogels were retained in the eye for the entire period of the study with no observed irritation. Pilocarpine-loaded hydrogels sustained pupillary constriction for 24 h after administration as compared to 3 h for the solution, an 8-fold increase in duration of action. A strong correlation between pilocarpine release and pupillary response was observed. In conclusion, the current studies demonstrate that in situ forming PEG hydrogels possess the viscoelastic, retention, and sustained delivery properties required for an efficient ocular drug delivery system. PMID:19341773

  14. Wrist Traction During MR Arthrography Improves Detection of Triangular Fibrocartilage Complex and Intrinsic Ligament Tears and Visibility of Articular Cartilage.

    PubMed

    Lee, Ryan K L; Griffith, James F; Ng, Alex W H; Nung, Ryan C H; Yeung, David K W

    2016-01-01

    The purpose of this study was to assess the effects of traction during MR arthrography of the wrist on joint space widening, cartilage visibility, and detection of tears of the triangular fibrocartilage complex (TFCC) and intrinsic ligaments. A prospective study included 40 wrists in 39 patients (25 men, 14 women; mean age, 35 years). MR arthrography was performed with a 3-T MRI system with and without axial traction. Two radiologists independently measured wrist and carpal joint space widths and semiquantitatively graded articular cartilage visibility. Using conventional arthrography as the reference standard and working in consensus, they assessed for the presence of tears of the TFCC, lunotriquetral ligament (LTL), and scapholunate ligament (SLL). Visibility of a tear before traction was compared with visibility after traction. With traction, all joint spaces in the wrist and carpus were significantly widened (change, 0.15-1.01 mm; all p < 0.006). Subjective cartilage visibility of all joint spaces improved after traction (all p ≤ 0.048) except for that of the radioscaphoid space, which was well visualized even before traction. Conventional arthrography depicted 24 TFCC tears, seven LTL tears, and three SLL tears. The accuracy of tear detection improved after traction for the TFCC (98% after traction vs 83% before traction), the LTL (100% vs 88%), and the SLL (100% vs 95%). Tear visibility improved after traction for 54% of TFCC tears, 71% of LTL tears, and 66% of SLL tears. Wrist MR arthrography with axial traction significantly improved the visibility of articular cartilage and the detection and visibility of tears of the TFCC and intrinsic ligaments. The results favor more widespread use of traction during MR arthrography of the wrist.

  15. Evaluating tear clearance rate with optical coherence tomography.

    PubMed

    Garaszczuk, Izabela K; Mousavi, Maryam; Cervino Exposito, Alejandro; Bartuzel, Maciej M; Montes-Micó, Robert; Iskander, D Robert

    2018-02-01

    To assess the early-phase of tear clearance rate (TCR) with anterior segment optical coherence tomography (OCT) and to determine the association between TCR and other clinical measures of the tear film in a group of young subjects with different levels of tear film quality. TCR was classified as the percentage decrease of subject's inferior tear meniscus height 30s after instillation of 5μl 0.9% saline solution. Fifty subjects (32F and 18M) aged (mean±standard deviation) 25.5±4.3 years volunteered for the study. It consisted of a review of medical history, Ocular Surface Disease Index (OSDI) questionnaire, tear film osmolarity measurements, slit lamp examination and TCR estimation based on dynamic measurements of the lower tear meniscus with OCT. Estimates of TCR were contrasted against subject age and tear film measures commonly used for dry eye diagnosis, which includes OSDI score, fluorescein tear film break-up time (FBUT), tear meniscus height (TMH), blinking frequency, tear film osmolarity and corneal staining. The group mean TCR was 29±13% and 36±19% respectively after 30 and 60s margin after saline solution instillation. Statistically significant correlations were found between TCR and FBUT (r 2 =0.319, p<0.001), blinking frequency (r 2 =0.138, p<0.01), tear film osmolarity (r 2 =0.133, p<0.01) and subject's age (r 2 =0.095, p<0.05). Anterior segment optical coherence tomography allows following changes of tear meniscus morphology post saline solution instillation and evaluating the TCR. OCT based TCR might be used as additional measure of the lacrimal functional unit. Copyright © 2017 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  16. Predicting Rotator Cuff Tears Using Data Mining and Bayesian Likelihood Ratios

    PubMed Central

    Lu, Hsueh-Yi; Huang, Chen-Yuan; Su, Chwen-Tzeng; Lin, Chen-Chiang

    2014-01-01

    Objectives Rotator cuff tear is a common cause of shoulder diseases. Correct diagnosis of rotator cuff tears can save patients from further invasive, costly and painful tests. This study used predictive data mining and Bayesian theory to improve the accuracy of diagnosing rotator cuff tears by clinical examination alone. Methods In this retrospective study, 169 patients who had a preliminary diagnosis of rotator cuff tear on the basis of clinical evaluation followed by confirmatory MRI between 2007 and 2011 were identified. MRI was used as a reference standard to classify rotator cuff tears. The predictor variable was the clinical assessment results, which consisted of 16 attributes. This study employed 2 data mining methods (ANN and the decision tree) and a statistical method (logistic regression) to classify the rotator cuff diagnosis into “tear” and “no tear” groups. Likelihood ratio and Bayesian theory were applied to estimate the probability of rotator cuff tears based on the results of the prediction models. Results Our proposed data mining procedures outperformed the classic statistical method. The correction rate, sensitivity, specificity and area under the ROC curve of predicting a rotator cuff tear were statistical better in the ANN and decision tree models compared to logistic regression. Based on likelihood ratios derived from our prediction models, Fagan's nomogram could be constructed to assess the probability of a patient who has a rotator cuff tear using a pretest probability and a prediction result (tear or no tear). Conclusions Our predictive data mining models, combined with likelihood ratios and Bayesian theory, appear to be good tools to classify rotator cuff tears as well as determine the probability of the presence of the disease to enhance diagnostic decision making for rotator cuff tears. PMID:24733553

  17. Effect of lipid-based dry eye supplements on the tear film in wearers of eye cosmetics.

    PubMed

    Wang, Michael T M; Cho, Irene Sung Hee; Jung, Soo Hee; Craig, Jennifer P

    2017-08-01

    To compare the effects on tear film parameters and contamination in cosmetic eyeliner wearers, after single application of two lipid-based dry eye treatments: a lipid-containing lubricant eye drop and a phospholipid liposomal spray. Fifty participants were enrolled in a prospective, randomised, paired-eye, investigator-masked trial. Pencil eyeliner (Body Shop ® Crayon Eye Definer) was applied to the upper eyelid periocular skin of both eyes, anterior to the lash line. Baseline tear film quality was assessed fifteen minutes after eyeliner application. A lubricant drop (Systane ® Balance) was then applied to one eye (randomised), and liposomal spray (Tears Again ® ) to the contralateral eye. Tear film contamination, lipid layer grade, non-invasive tear film break-up time and tear evaporation rate were evaluated fifteen minutes post-treatment and compared to pre-treatment values. Pre-treatment measurements did not differ between eyes assigned to lubricant drop and liposomal spray. Tear film contamination was observed in a greater proportion of eyes following both treatments (both p<0.05), with no significant difference between treatments (p=0.41). Both treatments improved lipid layer thickness (both p≤0.01), but effected no significant change in non-invasive tear film break-up time or tear evaporation rate (all p>0.05). Changes in tear film parameters did not differ between treatments (all p>0.05). Both the lipid-containing lubricant eye drop and phospholipid liposomal spray result in clinically apparent tear film contamination in eyeliner cosmetic wearers. Although both treatments effected an increase in lipid layer thickness, neither displayed clinical efficacy in improving tear film stability. Copyright © 2017 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  18. The evaluation of central corneal thickness and intraocular pressure in conjunction with tear IGF-1 levels in patients with acromegaly.

    PubMed

    Kan, Emrah; Kan, Elif K; Okuyucu, Ali

    2017-08-30

    To compare the central corneal thickness (CCT), intraocular pressure (IOP), and tear insulin-like growth factor 1 (IGF-1) levels between patients with acromegaly and a control group and to evaluate the possible effect of tear IGF-1 and duration of the disease on CCT and IOP. We included 31 patients with acromegaly (study group) and 40 age- and sex-matched controls in the study. Patients with acromegaly were divided into 2 subgroups based on disease status (active/inactive). All participants underwent complete ophthalmologic evaluation including CCT and IOP values. Basal tear samples were collected from both groups and tear IGF-1 levels were measured. The CCT, IOP, and tear IGF-1 levels were compared between groups and subgroups and the association between tear IGF-I levels and ocular parameters (CCT, IOP) and disease duration were also evaluated. Central corneal thickness, IOP, and tear IGF-1 levels did not show a significant difference between study and control groups. We also did not find a significant difference in terms of CCT, IOP, or tear IGF-1 levels between subgroups of patients. Correlation analysis did not show an association between the duration of disease and tear IGF-1 levels with CCT or IOP. There was no significant difference in tear IGF-1 levels between patients with acromegaly and controls. Additionally, there was no correlation between disease duration and tear IGF-1 levels with CCT or IOP levels. This lack of association may suggest that tear IGF-1 levels might not have an effect on CCT or IOP findings in patients with acromegaly.

  19. Rotator cuff muscle degeneration and tear severity related to myogenic, adipogenic, and atrophy genes in human muscle.

    PubMed

    Shah, Shivam A; Kormpakis, Ioannis; Cavinatto, Leonardo; Killian, Megan L; Thomopoulos, Stavros; Galatz, Leesa M

    2017-12-01

    Large rotator cuff tear size and advanced muscle degeneration can affect reparability of tears and compromise tendon healing. Clinicians often rely on direct measures of rotator cuff tear size and muscle degeneration from magnetic resonance imaging (MRI) to determine whether the rotator cuff tear is repairable. The objective of this study was to identify the relationship between gene expression changes in rotator cuff muscle degeneration to standard data available to clinicians. Radiographic assessment of preoperative rotator cuff tear severity was completed for 25 patients with varying magnitudes of rotator cuff tears. Tear width and retraction were measured using MRI, and Goutallier grade, tangent (tan) sign, and Thomazeau grade were determined. Expression of myogenic-, adipogenic-, atrophy-, and metabolism-related genes in biopsied muscles were correlated with tear width, tear retraction, Goutallier grade, tan sign, and Thomazeau grade. Tear width positively correlated with Goutallier grade in both the supraspinatus (r = 0.73) and infraspinatus (r = 0.77), along with tan sign (r = 0.71) and Thomazeau grade (r = 0.68). Decreased myogenesis (Myf5), increased adipogenesis (CEBPα, Lep, Wnt10b), and decreased metabolism (PPARα) correlated with radiographic assessments. Gene expression changes suggest that rotator cuff tears lead to a dramatic molecular response in an attempt to maintain normal muscle tissue, increase adipogenesis, and decrease metabolism. Fat accumulation and muscle atrophy appear to stem from endogenous changes rather than from changes mediated by infiltrating cells. Results suggest that chronic unloading of muscle, induced by rotator cuff tear, disrupts muscle homeostasis. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:2808-2814, 2017. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  20. Diagnostic accuracy of 3T conventional shoulder MRI in the detection of the long head of the biceps tendon tears associated with rotator cuff tendon tears.

    PubMed

    Lee, Ro Woon; Choi, Soo-Jung; Lee, Man Ho; Ahn, Jae Hong; Shin, Dong Rock; Kang, Chae Hoon; Lee, Ki Won

    2016-12-01

    To evaluate the diagnostic performance (DP) of 3T (3 Tesla field strength) conventional shoulder magnetic resonance imaging (MRI) in detecting the long head of the biceps tendon (LHBT) tears in association with rotator cuff tendon tears. This study included 80 consecutive patients who underwent arthroscopic surgery for rotator cuff tendon tears. Two radiologists independently evaluated the preoperative 3T shoulder MRI for the presence of LHBT tears. The DP of MRI was evaluated using the results of arthroscopy as the reference standard. We also evaluated the DP of several MR signs of LHBT in detection of partial LHBT tears. Arthroscopic examination revealed 35 partial and 5 complete tears. According to the results of evaluation by reviewers 1 and 2, shoulder MRI exhibited sensitivities of 77.14 and 80 % and specificities of 71.11 and 73.33 % in detection of partial LHBT tears and sensitivities of 80 and 100 % and a specificity of 100% (both) in detection of complete LHBT tears. In detecting partial LHBT tears, increased T2 signal intensity of the LHBT exhibited high sensitivities (reviewers 1 and 2; 82.85 and 80 %, respectively) and the presence of intratendinous defects or C-signs exhibited the highest specificities (reviewers 1 and 2; 95.55 and 93.33 %, respectively), followed by abnormalities in shape and outer margins of the LHBT (reviewers 1 and 2; 91.11 and 82 %; 91.11 and 86.66 %, respectively). Non-contrast-enhanced 3T shoulder MRI is potentially highly accurate in detection of complete LHBT tears, but moderately accurate in detection of partial LHBT tears.

  1. Atraumatic tears of the ligamentum teres are more frequent in professional ballet dancers than a sporting population.

    PubMed

    Mayes, Susan; Ferris, April-Rose; Smith, Peter; Garnham, Andrew; Cook, Jill

    2016-07-01

    To compare the frequency of atraumatic ligamentum teres (LT) tear in professional ballet dancers with that of athletes, and to determine the relationship with clinical and imaging findings. Forty-nine male and female professional ballet dancers (98 hips) and 49 age and sex-matched non-dancing athletes (98 hips) completed questionnaires on hip symptoms and physical activity levels, underwent hip rotation range of movement (ROM) and hypermobility testing, and 3.0-Tesla magnetic resonance imaging (3 T MRI) on both hips to detect LT tears, acetabular labral tears, and articular cartilage defects, and to measure the lateral centre edge angles (LCE). A higher frequency of LT tear was found in dancers (55 %) compared with athletes (22 %, P = 0.001). The frequency and severity of LT tears in dancers increased with older age (P = 0.004, P = 0.006, respectively). The Hip and Groin Outcome Score (HAGOS) pain scores or hip rotation ROM did not differ significantly among participants with normal, partial, or complete tears of LT (P > 0.01 for all). Neither the frequency of generalised joint hypermobility (P = 0.09) nor the LCE angles (P = 0.32, P = 0.16, left and right hips respectively) differed between those with and those without LT tear. In most hips, LT tear co-existed with either a labral tear or a cartilage defect, or both. The higher frequency of atraumatic LT tears in professional ballet dancers suggests that the LT might be abnormally loaded in ballet, and caution is required when evaluating MRI, as LT tears may be asymptomatic. A longitudinal study of this cohort is required to determine if LT tear predisposes the hip joint to osteoarthritis.

  2. Tear-Duct Obstruction and Surgery

    MedlinePlus

    ... Staying Safe Videos for Educators Search English Español Tear-Duct Obstruction and Surgery KidsHealth / For Parents / Tear- ... year old with little or no treatment. About Tear Ducts Our eyes are continually exposed to dust, ...

  3. Watery eyes

    MedlinePlus

    ... JavaScript. Watery eyes means you have too many tears draining from the eyes. Tears help keep the surface of the eye moist. ... the eye. Causes Your eyes are always making tears. These tears leave the eye through a small ...

  4. Application of maximum-likelihood estimation in optical coherence tomography for nanometer-class thickness estimation

    NASA Astrophysics Data System (ADS)

    Huang, Jinxin; Yuan, Qun; Tankam, Patrice; Clarkson, Eric; Kupinski, Matthew; Hindman, Holly B.; Aquavella, James V.; Rolland, Jannick P.

    2015-03-01

    In biophotonics imaging, one important and quantitative task is layer-thickness estimation. In this study, we investigate the approach of combining optical coherence tomography and a maximum-likelihood (ML) estimator for layer thickness estimation in the context of tear film imaging. The motivation of this study is to extend our understanding of tear film dynamics, which is the prerequisite to advance the management of Dry Eye Disease, through the simultaneous estimation of the thickness of the tear film lipid and aqueous layers. The estimator takes into account the different statistical processes associated with the imaging chain. We theoretically investigated the impact of key system parameters, such as the axial point spread functions (PSF) and various sources of noise on measurement uncertainty. Simulations show that an OCT system with a 1 μm axial PSF (FWHM) allows unbiased estimates down to nanometers with nanometer precision. In implementation, we built a customized Fourier domain OCT system that operates in the 600 to 1000 nm spectral window and achieves 0.93 micron axial PSF in corneal epithelium. We then validated the theoretical framework with physical phantoms made of custom optical coatings, with layer thicknesses from tens of nanometers to microns. Results demonstrate unbiased nanometer-class thickness estimates in three different physical phantoms.

  5. Diagnosing dry eye with dynamic-area high-speed videokeratoscopy

    NASA Astrophysics Data System (ADS)

    Alonso-Caneiro, David; Turuwhenua, Jason; Iskander, D. Robert; Collins, Michael J.

    2011-07-01

    Dry eye syndrome is one of the most commonly reported eye health conditions. Dynamic-area high-speed videokeratoscopy (DA-HSV) represents a promising alternative to the most invasive clinical methods for the assessment of the tear film surface quality (TFSQ), particularly as Placido-disk videokeratoscopy is both relatively inexpensive and widely used for corneal topography assessment. Hence, improving this technique to diagnose dry eye is of clinical significance and the aim of this work. First, a novel ray-tracing model is proposed that simulates the formation of a Placido image. This model shows the relationship between tear film topography changes and the obtained Placido image and serves as a benchmark for the assessment of indicators of the ring's regularity. Further, a novel block-feature TFSQ indicator is proposed for detecting dry eye from a series of DA-HSV measurements. The results of the new indicator evaluated on data from a retrospective clinical study, which contains 22 normal and 12 dry eyes, have shown a substantial improvement of the proposed technique to discriminate dry eye from normal tear film subjects. The best discrimination was obtained under suppressed blinking conditions. In conclusion, this work highlights the potential of the DA-HSV as a clinical tool to diagnose dry eye syndrome.

  6. Measurements of the momentum and current transport from tearing instability in the Madison Symmetric Torus reversed-field pinch

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kuritsyn, A.; Fiksel, G.; Almagri, A. F.

    2009-05-15

    In this paper measurements of momentum and current transport caused by current driven tearing instability are reported. The measurements are done in the Madison Symmetric Torus reversed-field pinch [R. N. Dexter, D. W. Kerst, T. W. Lovell, S. C. Prager, and J. C. Sprott, Fusion Technol. 19, 131 (1991)] in a regime with repetitive bursts of tearing instability causing magnetic field reconnection. It is established that the plasma parallel momentum profile flattens during these reconnection events: The flow decreases in the core and increases at the edge. The momentum relaxation phenomenon is similar in nature to the well established relaxationmore » of the parallel electrical current and could be a general feature of self-organized systems. The measured fluctuation-induced Maxwell and Reynolds stresses, which govern the dynamics of plasma flow, are large and almost balance each other such that their difference is approximately equal to the rate of change of plasma momentum. The Hall dynamo, which is directly related to the Maxwell stress, drives the parallel current profile relaxation at resonant surfaces at the reconnection events. These results qualitatively agree with analytical calculations and numerical simulations. It is plausible that current-driven instabilities can be responsible for momentum transport in other laboratory and astrophysical plasmas.« less

  7. Conjunctival Tear Layer Temperature, Evaporation, Hyperosmolarity, Inflammation, Hyperemia, Tissue Damage, and Symptoms: A Review of an Amplifying Cascade.

    PubMed

    McMonnies, Charles W

    2017-12-01

    This review examines the evidence for and significance of pre-conjunctival tear temperature being higher than central pre-corneal temperature with associated more rapid evaporation of warmer pre-conjunctival tears in normal eyes but especially in hyperemic dry eye disease. PubMed searches using the terms "evaporative dry eye," "conjunctival tear evaporation," "tear evaporation," and "dry eye conjunctival hyperemia" indicated 157, 49, 309, and 96 potentially relevant papers, respectively. Selections from these lists were the basis for examining the significance of the evidence relevant to pre-conjunctival tear layer temperature and evaporation. There is evidence supporting an amplifying inflammatory and para-inflammatory hyperemia dry eye cascade, which increases pre-conjunctival tear temperature and the risk of accelerated pre-conjunctival tear evaporation with exacerbated osmolarity elevation and inflammation. Dry eye cascade amplification is consistent with increases in symptoms and inflammatory as well as para-inflammatory hyperemia toward the end of the waking day. Apart from age-related conjunctivochalasis, dry eye-related conjunctival epithelial cell pathology including reduced goblet cell numbers and associated mucin deficiency, squamous metaplasia, and increased separation of cell layers could help to destabilize tears and facilitate evaporation as part of an amplifying cascade. Greater difficulty in assessing conjunctival tear break up may contribute to an underestimation of a role for faster evaporation of pre-conjunctival tears in dry eye disease and help explain any non-correspondence between symptoms and corneal signs of dry eye disease. Success with anti-inflammatory therapies for dry eye disease may be at least partly due to reductions in conjunctival hyperemia and deamplification of evaporative cascades. Conjunctival inflammatory hyperemia in other diseases may contribute to accelerated pre-conjunctival tear evaporation and the risk of tear-deficiency- associated exacerbation of those diseases including impaired responses to therapeutic approaches to them. Similarly, postsurgical conjunctival inflammation and associated acceleration of tear evaporation could contribute to delayed wound healing.

  8. Total IgE and eotaxin (CCL11) contents in tears of patients suffering from seasonal allergic conjunctivitis.

    PubMed

    Eperon, Simone; Berguiga, Marouen; Ballabeni, Pierluigi; Guex-Crosier, Catherine; Guex-Crosier, Yan

    2014-09-01

    To prospectively investigate patients with seasonal allergic conjunctivitis (SAC) during the pollen season and test associations between tears total IgE, eotaxin concentrations, and SAC severity. Enrolled patients presented ocular symptoms and clinical signs of SAC at the time of presentation. Ocular itching, hyperaemia, chemosis, eyelid swelling, and tearing were scored, and the sum of these scores was defined as the clinical score. Conjunctival papillae were separately graded. We measured eotaxin concentration in tears by an enzyme-linked immunosorbent assay (ELISA) and total tear IgE by Lacrytest strip. Among thirty patients (30 eyes), 11 showed neither tear IgE nor tear eotaxin, while 15 out of 19 patients with positive IgE values presented a positive amount of eotaxin in their tears (Fisher's test: p < 0.001). The mean eotaxin concentration was 641 ± 154 (SEM) pg/ml. In patients with no amount of tear IgE, we observed a lower conjunctival papilla grade than in patients whose tears contained some amount of IgE (trend test: p = 0.032). In the 15 patients whose tear eotaxin concentration was null, tear IgE concentration was 5.3 ± 3.5 arbitrary units; in the other 15 patients whose eotaxin was positive, IgE reached 21 ± 4.3 arbitrary U (Mann-Whitney: p < 0.001). We measured 127 ± 47 pg/ml eotaxin in patients with no history of SAC but newly diagnosed as suffering from SAC, and 852 ± 218 pg/ml eotaxin in patients with a known SAC (p = 0.008). In contrast, tear IgE concentrations of both groups did not differ statistically significantly (p = 0.947). If IgE and eotaxin secreted in tears are major contributors in SAC pathogenesis, they however act at different steps of the process.

  9. Classification of ulnar triangular fibrocartilage complex tears. A treatment algorithm for Palmer type IB tears.

    PubMed

    Atzei, A; Luchetti, R; Garagnani, L

    2017-05-01

    The classical definition of 'Palmer Type IB' triangular fibrocartilage complex tear, includes a spectrum of clinical conditions. This review highlights the clinical and arthroscopic criteria that enable us to categorize five classes on a treatment-oriented classification system of triangular fibrocartilage complex peripheral tears. Class 1 lesions represent isolated tears of the distal triangular fibrocartilage complex without distal radio-ulnar joint instability and are amenable to arthroscopic suture. Class 2 tears include rupture of both the distal triangular fibrocartilage complex and proximal attachments of the triangular fibrocartilage complex to the fovea. Class 3 tears constitute isolated ruptures of the proximal attachment of the triangular fibrocartilage complex to the fovea; they are not visible at radio-carpal arthroscopy. Both Class 2 and Class 3 tears are diagnosed with a positive hook test and are typically associated with distal radio-ulnar joint instability. If required, treatment is through reattachment of the distal radio-ulnar ligament insertions to the fovea. Class 4 lesions are irreparable tears due to the size of the defect or to poor tissue quality and, if required, treatment is through distal radio-ulnar ligament reconstruction with tendon graft. Class 5 tears are associated with distal radio-ulnar joint arthritis and can only be treated with salvage procedures. This subdivision of type IB triangular fibrocartilage complex tear provides more insights in the pathomechanics and treatment strategies. II.

  10. Interferometric measurements of the tear film irregularities on the human cornea

    NASA Astrophysics Data System (ADS)

    Szczesna, Dorota H.; Jaronski, Jaroslaw; Kasprzak, Henryk T.; Stenevi, Ulf

    2005-09-01

    The pre-ocular tear film is the most anterior refractive surface of the eye. Its stability plays an important role in the condition of vision from the optical and physiological point of view. If the eye is opened for a significantly long time or suffers from an anormalities in tear production, there appear isolated dry islands - break-ups - with a random distribution in the continuous lacrimal film. We applied an interferometric method - Lateral Shearing Technique for investigating the tear film stability and the smoothness of the tear film surface. This method is non-invasive and it is characterised by the high accuracy and sensitivity. Interferometry allows dynamic measurements of the tear film stability in real time by observation of interference fringes. The evaporation of tears and appearance of the breakups causes changes in the fringe geometry. Fast Fourier Transform has been used for quantitative assessment of the fringe smoothness and as a consequence of the tear film surface geometry. This paper presents the method used for quantitative evaluation of the tear film distribution on the cornea. Examples of interferograms recorded on eyes of patients with healthy eyes, suffering from dry eye syndrome and wearing contact lenses are also given. With our technique we were able to observe distinct differences in stability of the tear film between healthy and dry eyes, and the tear film on contact lenses.

  11. Bone mineralization changes of the glenoid in shoulders with symptomatic rotator cuff tear.

    PubMed

    Harada, Yohei; Yokoya, Shin; Akiyama, Yuji; Mochizuki, Yu; Ochi, Mitsuo; Adachi, Nobuo

    2018-06-06

    Computed tomography osteoabsorptiometry (CTO) is a method to analyze the stress distribution in joints by measuring the subchondral bone density. The purpose of this study was to evaluate the bone mineralization changes of the glenoid in shoulders with rotator cuff tears by CTO and to evaluate whether rotator cuff tears are associated with stress changes in the glenoid. In total, 32 patients, who were diagnosed with unilateral rotator cuff tears and underwent arthroscopic rotator cuff repair, were enrolled in this study. They underwent CT scanning of both shoulders pre-operatively and the glenoid was evaluated using CTO. Hounsfield units (HU) in seven areas of the glenoid were compared between the affected and unaffected sides. The central area of the glenoid on the affected side had significantly lower HU than on the unaffected side among all patients. Focusing on the rotator cuff tear size and the subscapularis tendon, only patients with larger cuff tears or with subscapularis tendon tears showed significantly lower HU in the central area of the affected side. This study showed a decrease in bone mineralization density in the central glenoid in shoulders with rotator cuff tear. This change was observed in the case of larger cuff tears and subscapularis tendon tears. Our results help clarify the changes in stress distribution in the shoulder joint caused by symptomatic rotator cuff tears.

  12. New testing options for diagnosing and grading dry eye disease.

    PubMed

    Foulks, Gary N; Pflugfelder, Stephen C

    2014-06-01

    To describe new options for diagnosis and severity grading of dry eye disease. Perspective on technological advancements to identify tear dysfunction and their value in diagnosing and grading dry eye disease. Evidence is presented on new and evolving technologies to measure tear stability, composition, and meniscus height and their role in dry eye diagnosis and therapeutic efficacy grading is assessed. Evolving concepts regarding pathogenesis and new technologies to evaluate the tears and ocular surface have improved the ability to diagnose, classify, and grade the severity of dry eye disease. New technologies include noninvasive imaging of tear stability and tear meniscus height as a measure of tear volume and tear composition (osmolarity, lacrimal factors, inflammatory mediators, growth and differentiation factors). Approved tests, such as tear osmolarity and tear imaging, are being integrated into clinical practice and may eventually supplant certain traditional tests that have greater variability and less sensitivity. Other tests, such as molecular assays of tears and conjunctival cells, are currently being used in studies investigating pathogenesis and therapeutic mechanism of action. They may eventually translate to routine clinical practice. New technologies have emerged that can noninvasively evaluate the tears and measure disease-associated compositional changes. These tests are being integrated into clinical practice and therapeutic trials for diagnosis, classification, and severity grading of dry eye disease. Copyright © 2014 Elsevier Inc. All rights reserved.

  13. Partial articular-sided rotator cuff tears: in situ repair versus tear completion prior to repair.

    PubMed

    Sethi, Paul M; Rajaram, Arun; Obopilwe, Elifho; Mazzocca, Augustus D

    2013-06-01

    Uncertainty exists over the ideal surgical treatment method for partial articular-sided rotator cuff tears, with options ranging from debridement to in situ repair to tear completion prior to repair. The purpose of this study was to determine whether in situ repair was a viable biomechanical treatment option compared with tear completion prior to repair of partial articular-sided rotator cuff tears. Fourteen fresh-frozen cadaveric shoulders were dissected. Partial articular-sided tears were created and repaired using in situ repair or tear completion prior to the repair. Strain and displacement were measured at 45°, 60°, and 90° of glenohumeral abduction. Testing was performed with a load of 100 N applied for 30 cycles. Data from the biomechanical testing displayed 4 conditions that showed improved characteristics of in situ repair over completion and repair: bursal-sided strain anteriorly at 45°, bursal-sided strain anteriorly at 90°, bursal-sided displacement anteriorly at 45°, and bursal-sided displacement anteriorly at 90°. The data indicate that in situ repair is a viable biomechanical treatment option compared with tear completion prior to repair of partial articular-sided rotator cuff tears. When clinically appropriate, the in situ repair may offer some biomechanical advantages, with lower strain and displacement observed on the bursal side compared with tear completion prior to repair. Copyright 2013, SLACK Incorporated.

  14. Blocked Tear Duct

    MedlinePlus

    ... of the nose (lacrimal sac). From there tears travel down a duct (the nasolacrimal duct) draining into your nose. Once in the nose, tears are reabsorbed. A blockage can occur at any point in the tear drainage system, from the puncta ...

  15. Metabolomics and Trace Element Analysis of Camel Tear by GC-MS and ICP-MS.

    PubMed

    Ahamad, Syed Rizwan; Raish, Mohammad; Yaqoob, Syed Hilal; Khan, Altaf; Shakeel, Faiyaz

    2017-06-01

    Camel tear metabolomics and elemental analysis are useful in getting the information regarding the components responsible for maintaining the protective system that allows living in the desert and dry regions. The aim of this study was to correlate that the camel tears can be used as artificial tears for the evaluation of dryness in the eye. Eye biomarkers of camel tears were analyzed by gas chromatography-mass spectroscopy (GC-MS) and inductively coupled plasma mass spectroscopy (ICP-MS). The major compounds detected in camel tears by GC-MS were alanine, valine, leucine, norvaline, glycine, cadaverine, urea, ribitol, sugars, and higher fatty acids like octadecanoic acid and hexadecanoic acid. GC-MS analysis of camel tears also finds several products of metabolites and its associated metabolic participants. ICP-MS analysis showed the presence of different concentration of elemental composition in the camel tears.

  16. Hot-tearing of multicomponent Al-Cu alloys based on casting load measurements in a constrained permanent mold

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sabau, Adrian S; Mirmiran, Seyed; Glaspie, Christopher

    Hot-tearing is a major casting defect that is often difficult to characterize, especially for multicomponent Al alloys used for cylinder head castings. The susceptibility of multicomponent Al-Cu alloys to hot-tearing during permanent mold casting was investigated using a constrained permanent mold in which the load and displacement was measured. The experimental results for hot tearing susceptibility are compared with those obtained from a hot-tearing criterion based temperature range evaluated at fraction solids of 0.87 and 0.94. The Cu composition was varied from approximately 5 to 8 pct. (weight). Casting experiments were conducted without grain refining. The measured load during castingmore » can be used to indicate the severity of hot tearing. However, when small hot-tears are present, the load variation cannot be used to detect and assess hot-tearing susceptibility.« less

  17. Sphincter tears in primiparous women: Is age a factor?

    PubMed Central

    BOWLING, C. Bryce; WHEELER, Thomas L.; GERTEN, Kimberly A.; CHAPMAN, Victoria R.; BURGIO, Kathryn L.; RICHTER, Holly E.

    2011-01-01

    Introduction and Hypothesis Anal sphincter tears during vaginal delivery may result in serious sequelae. We examined whether younger primiparous patients were at increased risk for sphincter tears during vaginal delivery. Methods Data from an obstetric automated record were analyzed. Primiparous women delivering term infants (n = 5,937) were included to test for an association between age and sphincter tear rates. Three age groups were considered: young adolescents (≤16 years), older adolescents (17-20 years) and adults (≥21 years). Results No significant difference was found in tear rates among age cohorts (9.2%, 8.0%, and 9.6% respectively; p = 0.12). Logistic regression modeling revealed that young adolescents were not more likely to have sphincter tears compared to older cohorts. Conclusions Younger adolescents may not be at increased risk of anal sphincter tears. Decisions regarding interventions to decrease sphincter tears during vaginal delivery should not be made on the basis of maternal age alone. PMID:18985267

  18. Meniscus root repair.

    PubMed

    Vyas, Dharmesh; Harner, Christopher D

    2012-06-01

    Root tears are a subset of meniscal injuries that result in significant knee joint pathology. Occurring on either the medial or lateral side, root tears are defined as radial tears or avulsions of the posterior horn attachment to bone. After a root tear, there is a significant increase in tibio-femoral contact pressure concomitant with altered knee joint kinematics. Previous cadaver studies from our institution have shown that root repair of the medial meniscus is successful in restoring joint biomechanics to within normal limits. Indications for operative management of meniscal root tears include (1) a symptomatic medial meniscus root tear with minimal arthritis and having failed non-operative treatment, and (2) a lateral root tear in associated with an ACL tear. In this review, we describe diagnosis, imaging, patient selection, and arthroscopic surgical technique of medial and lateral meniscus root injuries. In addition we highlight the pearls of repair technique, associated complications, post-operative rehabilitation regimen, and expected outcomes.

  19. Water Hammer Simulations of MMH Propellant - New Capability Demonstration of the Generalized Fluid Flow Simulation Program

    NASA Technical Reports Server (NTRS)

    Burkhardt, Z.; Ramachandran, N.; Majumdar, A.

    2017-01-01

    Fluid Transient analysis is important for the design of spacecraft propulsion system to ensure structural stability of the system in the event of sudden closing or opening of the valve. Generalized Fluid System Simulation Program (GFSSP), a general purpose flow network code developed at NASA/MSFC is capable of simulating pressure surge due to sudden opening or closing of valve when thermodynamic properties of real fluid are available for the entire range of simulation. Specifically GFSSP needs an accurate representation of pressure-density relationship in order to predict pressure surge during a fluid transient. Unfortunately, the available thermodynamic property programs such as REFPROP, GASP or GASPAK does not provide the thermodynamic properties of Monomethylhydrazine (MMH). This paper will illustrate the process used for building a customized table of properties of state variables from available properties and speed of sound that is required by GFSSP for simulation. Good agreement was found between the simulations and measured data. This method can be adopted for modeling flow networks and systems with other fluids whose properties are not known in detail in order to obtain general technical insight. Rigorous code validation of this approach will be done and reported at a future date.

  20. Randomized Controlled Study to Investigate the Effect of Topical Diquafosol Tetrasodium on Corneal Sensitivity in Short Tear Break-Up Time Dry Eye.

    PubMed

    Kaido, Minako; Kawashima, Motoko; Shigeno, Yuta; Yamada, Yoshiaki; Tsubota, Kazuo

    2018-05-01

    Complex mechanisms underlie dry eye (DE) symptom provocation. In particular, corneal hypersensitivity may provoke symptoms in short tear break-up time (BUT) DE characterized by tear film instability. We hypothesized that improved tear film stability may alleviate corneal sensitivity in patients with short tear BUT DE. Therefore, we investigated the effect of topical diquafosol tetrasodium (DQS) on corneal sensitivity in unstable tear film DE. This prospective, randomized study included 27 subjects (age: 39.1 ± 8.4 years; range: 25-59 years) with short tear BUT DE, defined based on the presence of DE symptoms and tear film instability. Subjects were randomly divided into DQS (3% DQS, 12 subjects) and artificial tear (AT; preservative-free AT, 15 subjects) groups. Subjects applied the medication 6 times a day for 5 weeks. The perception of touch (S-touch) and pain (S-pain) sensitivity was measured using a Cochet-Bonnet esthesiometer. Tear evaluation, corneal sensitivity, and DE symptoms were compared before and after DQS or AT administration. The correlation between the improvement degrees of corneal sensitivity and DE symptoms following medication was analyzed. DQS significantly improved tear BUT and tear meniscus height (TMH) scores (p < 0.05), while AT significantly improved tear BUT (p < 0.05) but not TMH score. Mean S-pain and DE symptom scores were lower after medication use in the DQS (S-pain and DE symptoms: p  < 0.05) and AT groups (S-pain: p  = 0.05; DE symptoms: p  < 0.05). However, S-touch did not change significantly in either group. A positive correlation was observed between the improvement degrees of S-pain and DE symptoms in the overall subjects studied. Both DQS and AT alleviate corneal hypersensitivity and DE symptoms in eyes with short tear BUT DE. However, DQS seems to be more effective to adjust tear environment, leading to the normalization of corneal sensitivity and DE symptoms. UMIN Clinical Trials Registry Identifier, UMIN000014536.

  1. A mass and solute balance model for tear volume and osmolarity in the normal and the dry eye.

    PubMed

    Gaffney, E A; Tiffany, J M; Yokoi, N; Bron, A J

    2010-01-01

    Tear hyperosmolarity is thought to play a key role in the mechanism of dry eye, a common symptomatic condition accompanied by visual disturbance, tear film instability, inflammation and damage to the ocular surface. We have constructed a model for the mass and solute balance of the tears, with parameter estimation based on extensive data from the literature which permits the influence of tear evaporation, lacrimal flux and blink rate on tear osmolarity to be explored. In particular the nature of compensatory events has been estimated in aqueous-deficient (ADDE) and evaporative (EDE) dry eye. The model reproduces observed osmolarities of the tear meniscus for the healthy eye and predicts a higher concentration in the tear film than meniscus in normal and dry eye states. The differential is small in the normal eye, but is significantly increased in dry eye, especially for the simultaneous presence of high meniscus concentration and low meniscus radius. This may influence the interpretation of osmolarity values obtained from meniscus samples since they need not fully reflect potential damage to the ocular surface caused by tear film hyperosmolarity. Interrogation of the model suggests that increases in blink rate may play a limited role in compensating for a rise in tear osmolarity in ADDE but that an increase in lacrimal flux, together with an increase in blink rate, may delay the development of hyperosmolarity in EDE. Nonetheless, it is predicted that tear osmolarity may rise to much higher levels in EDE than ADDE before the onset of tear film breakup, in the absence of events at the ocular surface which would independently compromise tear film stability. Differences in the predicted responses of the pre-ocular tears in ADDE compared to EDE or hybrid disease to defined conditions suggest that no single, empirically-accessible variable can act as a surrogate for tear film concentration and the potential for ocular surface damage. This emphasises the need to measure and integrate multiple diagnostic indicators to determine outcomes and prognosis. Modelling predictions in addition show that further studies concerning the possibility of a high lacrimal flux phenotype in EDE are likely to be profitable.

  2. The risk of stanford type-A aortic dissection with different tear size and location: a numerical study.

    PubMed

    Shi, Yue; Zhu, Minjia; Chang, Yu; Qiao, Huanyu; Liu, Yongmin

    2016-12-28

    This study is to investigate the influence of hemodynamics on Stanford type-A aortic dissection with different tear size and location, to provide some support for the relationships between the risks (rupture, reverse tearing and further tearing) and tear size and location for clinical treatment. Four numerical models of Stanford type-A aortic dissection were established, with different size and location of the tears. The ratio of the area between the entry and re-entry tears(RA) is various within the model; while, the size and the location of the re-entry in the distal descending aorta are fixed. In model A11 and A21, the entry tears are located near the ascending aorta. The RA in these models are 1 and 2, respectively; In the model B11 and B21, the entry tears are located near the proximal descending aorta and the RA in these models are again assigned to 1 and 2, respectively. Then hemodynamics in these models was solved with numerically and the flow patterns and loading distributions were investigated. The flow velocity of the true lumen in model A21, B21 is lower than that in A11, B11, respectively; the time-averaged wall shear stress (TAWSS) of the false lumen in model A21 and B21 is higher, and for ascending aorta false lumen, A11, A21 are higher than B11, B21, respectively. False lumen intimal wall pressure of A11, A21 are always higher than the true lumen ones. The variation of the RA can significantly affect the dynamics of blood within the aortic dissection. When the entry tear size is larger than the re-entry tear ones, the false lumen, proximal descending aorta and the wall near re-entry tear are prone to cracking. Entry tear location can significantly alter the hemodynamics of aortic dissection as well. When entry tear location is closer to proximal ascending aorta, false lumen continues to expand and compress the true lumen resulting in the true lumen reduction. For proximal ascending aorta, high pressure in false lumen predicts a higher risk of reverse tear.

  3. Monte Carlo simulations of dipolar and quadrupolar linear Kihara fluids. A test of thermodynamic perturbation theory

    NASA Astrophysics Data System (ADS)

    Garzon, B.

    Several simulations of dipolar and quadrupolar linear Kihara fluids using the Monte Carlo method in the canonical ensemble have been performed. Pressure and internal energy have been directly determined from simulations and Helmholtz free energy using thermodynamic integration. Simulations were carried out for fluids of fixed elongation at two different densities and several values of temperature and dipolar or quadrupolar moment for each density. Results are compared with the perturbation theory developed by Boublik for this same type of fluid and good agreement between simulated and theoretical values was obtained especially for quadrupole fluids. Simulations are also used to obtain the liquid structure giving the first few coefficients of the expansion of pair correlation functions in terms of spherical harmonics. Estimations of the triple point temperature to critical temperature ratio are given for some dipole and quadrupole linear fluids. The stability range of the liquid phase of these substances is shortly discussed and an analysis about the opposite roles of the dipole moment and the molecular elongation on this stability is also given.

  4. Tear cytokine profile as a noninvasive biomarker of inflammation for ocular surface diseases: standard operating procedures.

    PubMed

    Wei, Yi; Gadaria-Rathod, Neha; Epstein, Seth; Asbell, Penny

    2013-12-23

    To provide standard operating procedures (SOPs) for measuring tear inflammatory cytokine concentrations and to validate the resulting profile as a minimally invasive objective metric and biomarker of ocular surface inflammation for use in multicenter clinical trials on dry eye disease (DED). Standard operating procedures were established and then validated with cytokine standards, quality controls, and masked tear samples collected from local and distant clinical sites. The concentrations of the inflammatory cytokines in tears were quantified using a high-sensitivity human cytokine multiplex kit. A panel of inflammatory cytokines was initially investigated, from which four key inflammatory cytokines (IL-1β, IL-6, INF-γ, and TNF-α) were chosen. Results with cytokine standards statistically satisfied the manufacturer's quality control criteria. Results with pooled tear samples were highly reproducible and reliable with tear volumes ranging from 4 to 10 μL. Incorporation of the SOPs into clinical trials was subsequently validated. Tear samples were collected at a distant clinical site, stored, and shipped to our Biomarker Laboratory, where a masked analysis of the four tear cytokines was successfully performed. Tear samples were also collected from a feasibility study on DED. Inflammatory cytokine concentrations were decreased in tears of subjects who received anti-inflammatory treatment. Standard operating procedures for human tear cytokine assessment suitable for multicenter clinical trials were established. Tear cytokine profiling using these SOPs may provide objective metrics useful for diagnosing, classifying, and analyzing treatment efficacy in inflammatory conditions of the ocular surface, which may further elucidate the mechanisms involved in the pathogenesis of ocular surface disease.

  5. The Relationship between Metabolic Syndrome, Its Components, and Dry Eye: A Cross-Sectional Study.

    PubMed

    Erdur, Sevil Karaman; Aydin, Rukiye; Ozsutcu, Mustafa; Olmuscelik, Oktay; Eliacik, Mustafa; Demirci, Goktug; Kocabora, Mehmet Selim

    2017-08-01

    The aim of this study was to evaluate tear osmolarity and tear film function and ocular surface changes in patients with metabolic syndrome. 108 eyes of 64 patients with metabolic syndrome (group 1) and 110 eyes of 55 healthy individuals (group 2) were included in this cross-sectional study. All participants were evaluated using the Ocular Surface Disease Index (OSDI) questionnaire, Schirmer I test, tear film break-up time (TBUT), and tear osmolarity. Main outcome measures were Ocular Surface Disease Index (OSDI) questionnaire, Schirmer I test, tear film break-up time (TBUT), and tear osmolarity values. Tear osmolarity values and OSDI scores were significantly higher in group 1 (314.4 ± 19.1 mOsm and 38.9 ± 1.1, respectively) compared with group 2 (295 ± 14.3 mOsm and 18.69 ± 17.2, respectively) (p = 0.01 for both). The Schirmer test values and TBUT in group 1 (10 ± 3.7 mm and 14.8 ± 3.6 sec, respectively) were significantly lower compared with group 2 (16.8 ± 2.6 mm and 18.1 ± 0.5 sec, respectively) (p < 0.001 for both). There was significant correlation between tear osmolarity versus waist circumference and fasting blood glucose in the study group (r = 0.364, p = 0.04; and r = 0.542, p ≤ 0.001, respectively). This study showed that metabolic syndrome can influence tear osmolarity and tear film function. Patients with metabolic syndrome showed tear hyperosmolarity and tear film dysfunction.

  6. Subregional effects of meniscal tears on cartilage loss over 2 years in knee osteoarthritis.

    PubMed

    Chang, Alison; Moisio, Kirsten; Chmiel, Joan S; Eckstein, Felix; Guermazi, Ali; Almagor, Orit; Cahue, September; Wirth, Wolfgang; Prasad, Pottumarthi; Sharma, Leena

    2011-01-01

    Meniscal tears have been linked to knee osteoarthritis progression, presumably by impaired load attenuation. How meniscal tears affect osteoarthritis is unclear; subregional examination may help to elucidate whether the impact is local. This study examined the association between a tear within a specific meniscal segment and subsequent 2-year cartilage loss in subregions that the torn segment overlies. Participants with knee osteoarthritis underwent bilateral knee MRI at baseline and 2 years. Mean cartilage thickness within each subregion was quantified. Logistic regression with generalised estimating equations were used to analyse the relationship between baseline meniscal tear in each segment and baseline to 2-year cartilage loss in each subregion, adjusting for age, gender, body mass index, tear in the other two segments and extrusion. 261 knees were studied in 159 individuals. Medial meniscal body tear was associated with cartilage loss in external subregions and in central and anterior tibial subregions, and posterior horn tear specifically with posterior tibial subregion loss; these relationships were independent of tears in the other segments and persisted in tibial subregions after adjustment for extrusion. Lateral meniscal body and posterior horn tear were also associated with cartilage loss in underlying subregions but not after adjustment for extrusion. Cartilage loss in the internal subregions, not covered by the menisci, was not associated with meniscal tear in any segment. These results suggest that the detrimental effect of meniscal tears is not spatially uniform across the tibial and femoral cartilage surfaces and that some of the effect is experienced locally.

  7. Complete vs partial-thickness tears of the posterior cruciate ligament: MR findings.

    PubMed

    Patten, R M; Richardson, M L; Zink-Brody, G; Rolfe, B A

    1994-01-01

    We sought to define the MRI appearance of both complete and partial-thickness tears of the posterior cruciate ligament (PCL) and to describe patterns of injury and associated MRI findings. Three radiologists retrospectively reviewed MR images and medical records on 32 patients with PCL tears (15 complete, 17 partial) and correlated MRI findings to results of clinical testing and surgery. The PCL had indistinct margins in 27 (84%) of 32 patients and was abnormally thick in 25 (78%) patients. In 31 (97%) patients, the torn PCL showed increased signal intensity on both T1- and T2-weighted pulse sequences. Although there was no statistically significant difference between patients with complete tears and those with partial tears with regard to thickness, margination, and signal intensity of the PCL, MR images in patients with complete tears were more likely to show focal areas of ligamentous discontinuity (10 of 15 cases) (p = 0.01). Associated knee injuries were seen in 21 (66%) patients and were seen more frequently in patients with complete PCL tears (p = 0.015). Bony injury (n = 11, 34%) and tears of the medial collateral ligament (n = 13, 41%) and menisci (n = 10, 31%) were common. No specific pattern of bony injury was found. Posterior cruciate ligament tears can be diagnosed readily by multiplanar MRI using both morphological and signal intensity characteristics. Although differentiation between complete and partial-thickness PCL tears by MRI criteria alone is more problematic, complete tears are more likely to show focal areas of discontinuity and partial tears are more likely to show at least some intact fibers.

  8. Age-related changes in the signal value of tears.

    PubMed

    Zeifman, Debra M; Brown, Sarah A

    2011-08-12

    Emotional tears may be uniquely human and are an effective signal of distress in adults. The present study explored whether tears signal distress in younger criers and whether the effect of tears on observers is similar in magnitude across the life span. Participants rated photographs of crying infants, young children, and adults, with tears digitally removed or added. The effectiveness of tears in conveying sadness and eliciting sympathy was greatest for images of adults, intermediate for images of children, and least potent for images of infants. These findings suggest that the signal value of tears varies with the age of the crier. The results may shed light on the functional significance of crying at different stages of human development.

  9. Relationship of Tear Size and Location to Fatty Degeneration of the Rotator Cuff

    PubMed Central

    Kim, H. Mike; Dahiya, Nirvikar; Teefey, Sharlene A.; Keener, Jay D.; Galatz, Leesa M.; Yamaguchi, Ken

    2010-01-01

    Background: Fatty degeneration of the rotator cuff muscles may have detrimental effects on both anatomical and functional outcomes following shoulder surgery. The purpose of this study was to investigate the relationship between tear geometry and muscle fatty degeneration in shoulders with a deficient rotator cuff. Methods: Ultrasonograms of both shoulders of 262 patients were reviewed to assess the type of rotator cuff tear and fatty degeneration in the supraspinatus and infraspinatus muscles. The 251 shoulders with a full-thickness tear underwent further evaluation for tear size and location. The relationship of tear size and location to fatty degeneration of the supraspinatus and infraspinatus muscles was investigated with use of statistical comparisons and regression models. Results: Fatty degeneration was found almost exclusively in shoulders with a full-thickness rotator cuff tear. Of the 251 shoulders with a full-thickness tear, eighty-seven (34.7%) had fatty degeneration in either the supraspinatus or infraspinatus, or both. Eighty-two (32.7%) of the 251 full-thickness tears had a distance of 0 mm between the biceps tendon and anterior margin of the tear. Ninety percent of the full-thickness tears with fatty degeneration in both muscles had a distance of 0 mm posterior from the biceps, whereas only 9% of those without fatty degeneration had a distance of 0 mm. Tears with fatty degeneration had significantly greater width and length than those without fatty degeneration (p < 0.0001). Tears with fatty degeneration had a significantly shorter distance posterior from the biceps than those without fatty degeneration (p < 0.0001). The distance posterior from the biceps was found to be the most important predictor for supraspinatus fatty degeneration, whereas tear width and length were found to be the most important predictors for infraspinatus fatty degeneration. Conclusions: Fatty degeneration of the rotator cuff muscles is closely associated with tear size and location. The finding of this study suggests that the integrity of the anterior supraspinatus tendon is important to the development of fatty degeneration. Patients with full-thickness tears that extend through this area may benefit from earlier surgical intervention if fatty degeneration has not already occurred. Additionally, the findings suggest the importance of secure fixation and healing of the anterior aspect of the supraspinatus with surgical repair. PMID:20360505

  10. Immersed Boundary Simulations of Active Fluid Droplets

    PubMed Central

    Hawkins, Rhoda J.

    2016-01-01

    We present numerical simulations of active fluid droplets immersed in an external fluid in 2-dimensions using an Immersed Boundary method to simulate the fluid droplet interface as a Lagrangian mesh. We present results from two example systems, firstly an active isotropic fluid boundary consisting of particles that can bind and unbind from the interface and generate surface tension gradients through active contractility. Secondly, a droplet filled with an active polar fluid with homeotropic anchoring at the droplet interface. These two systems demonstrate spontaneous symmetry breaking and steady state dynamics resembling cell motility and division and show complex feedback mechanisms with minimal degrees of freedom. The simulations outlined here will be useful for quantifying the wide range of dynamics observable in these active systems and modelling the effects of confinement in a consistent and adaptable way. PMID:27606609

  11. Radial tears associated with cleavage tears of the medial meniscus in athletes.

    PubMed

    Kidron, Amos; Thein, Rafael

    2002-03-01

    To evaluate the significance of a small radial tear in the root of the posterior horn of the medial meniscus in an otherwise normal-looking meniscus in individuals who play vigorous sports. Retrospective review. Arthroscopy was performed in 1,270 patients; 11 patients (0.86%) had a small radial tear in the root of the medial meniscus. Trimming of the tear revealed a large horizontal cleavage tear of the posterior horn and body of the meniscus. The average age of the affected patients was 29.6 years (range, 21 to 45 years), and all were active in sports. Magnetic resonance imaging was of dubious diagnostic value. Three patients had undergone previous arthroscopy at which time the small radial root tear had been noted but was not thought to warrant treatment. All 11 patients returned to their former levels of activity after adequate surgery. When a radial root tear in the medial meniscus is found in an athletic patient, the edges of the tear should be trimmed, the root of the medial meniscus examined, and any additional torn cartilage resected.

  12. Patterns of meniscal tears associated with anterior cruciate ligament lesions in athletes.

    PubMed

    Binfield, P M; Maffulli, N; King, J B

    1993-09-01

    In this study, 400 clinically anterior cruciate ligament (ACL) deficient knees were arthroscoped and studied prospectively in the period January 1986 to April 1992. An ACL tear was always confirmed, and 41 per cent of these patients did not have an associated meniscal tear. In 30.25 per cent the lateral meniscus was torn; in 21.25 per cent the ACL tear was associated with a medial meniscus tear, and in the remaining 7 per cent both menisci were torn. The most frequently associated meniscal injury was the bucket handle tear of the medial meniscus (9 per cent), followed by the posterior horn tear of the lateral meniscus, which showed the same frequency as the ragged (or degenerated) tear of the lateral meniscus (6 per cent). The horizontal tear of the posterior part of the lateral meniscus showed a prevalence of 4.3 per cent. This picture is probably dependent on a secondary referral nature of the centre surveyed, in which the average time between injury and arthroscopy was 23.3 months.

  13. Ocular Pharmacology of Tear Film, Dry Eye, and Allergic Conjunctivitis.

    PubMed

    Gulati, Shilpa; Jain, Sandeep

    2017-01-01

    Dry Eye Disease (DED) is "a multifactorial disease of the tears and ocular surface that results in symptoms of discomfort, visual disturbance, and tear-film instability with potential damage to the ocular surface." DED comprises two etiologic categories: aqueous-deficient dry eye (ADDE) and evaporative dry eye (EDE). Diagnostic workup of DED should include clinical history, symptom questionnaire, fluorescein TBUT, ocular surface staining grading, Schirmer I/II, lid and meibomian pathology, meibomian expression, followed by other available tests. New diagnostic tests employ the Oculus Keratograph, which performs non-invasive tear-film analysis and a bulbar redness (BR). The TearLab Osmolarity Test enables rapid clinical evaluation of tear osmolarity. Lipiview is a recently developed diagnostic tool that uses interferometry to quantitatively evaluate tear-film thickness. In DED, epithelial and inflammatory cells produce a variety of inflammatory mediators. A stagnant tear film and decreased concentration of mucin result in the accumulation of inflammatory factors that can penetrate tight junctions and cause epithelial cell death. DED treatment algorithms are based on severity of clinical signs and symptoms, and disease etiology. Therapeutic approaches include lubricating artificial tears and immunomodulatory agents.

  14. Mechanical and Morphological Effect of Plant Based Antimicrobial Solutions on Maxillofacial Silicone Elastomer.

    PubMed

    Tetteh, Sophia; Bibb, Richard J; Martin, Simon J

    2018-05-30

    The objective of this study was to determine the effect of plant based antimicrobial solutions specifically tea tree and Manuka oil on facial silicone elastomers. The purpose of this in vitro study was to evaluate the effect of disinfection with plant extract solution on mechanical properties and morphology on the silicone elastomer. Test specimens were subjected to disinfection using tea tree oil, Manuka oil and the staphylococcus epidermidis bacteria. Furthermore, a procedure duration was used in the disinfection process to simulate up to one year of usage. Over 500 test specimens were fabricated for all tests performed namely hardness, elongation, tensile, tear strength tests, visual inspection and lastly surface characterization using SEM. A repeated measures ANOVA revealed that hardness and elongation at break varied significantly over the time period, whereas this was not observed in the tear and tensile strength parameters of the test samples.

  15. Resistive MHD modelling of the quasi-single helicity state in the KTX regimes

    NASA Astrophysics Data System (ADS)

    Luo, Bing; Zhu, Ping; Li, Hong; Liu, Wandong; KTX Team

    2018-01-01

    The potential formation of a quasi-single-helicity (QSH) state in the Keda Torus eXperiment (KTX) is investigated in resistive MHD simulations using the NIMROD code. We focus on the effects of finite resistivity on the mode structure and characteristics of the dominant linear and nonlinear resistive tearing-mode in a finite β, cylindrical configuration of a reversed field pinch model for KTX. In the typical resistive regimes of KTX where the Lundquist number S=5 × 104 , the plasma transitions to a steady QSH state after evolving through an initial transient phase with multiple helicities. The dominant mode of the QSH state develops from the dominant linear tearing mode instability. In the lower β regime, the QSH state is intermittent and short in duration; in the higher β regime, the QSH state persists for a longer time and should be more easily observed in experiments.

  16. Impact of a large density gradient on linear and nonlinear edge-localized mode simulations

    DOE PAGES

    Xi, P. W.; Xu, X. Q.; Xia, T. Y.; ...

    2013-09-27

    Here, the impact of a large density gradient on edge-localized modes (ELMs) is studied linearly and nonlinearly by employing both two-fluid and gyro-fluid simulations. In two-fluid simulations, the ion diamagnetic stabilization on high-n modes disappears when the large density gradient is taken into account. But gyro-fluid simulations show that the finite Larmor radius (FLR) effect can effectively stabilize high-n modes, so the ion diamagnetic effect alone is not sufficient to represent the FLR stabilizing effect. We further demonstrate that additional gyroviscous terms must be kept in the two-fluid model to recover the linear results from the gyro-fluid model. Nonlinear simulations show that the density variation significantly weakens the E × B shearing at the top of the pedestal and thus leads to more energy loss during ELMs. The turbulence spectrum after an ELM crash is measured and has the relation ofmore » $$P(k_{z})\\propto k_{z}^{-3.3}$$ .« less

  17. [The correlations between corneal sensation, tear meniscus volume, and tear film osmolarity after femtosecond laser-assisted LASIK].

    PubMed

    Zhang, Luyan; Sun, Xiyu; Yu, Ye; Xiong, Yan; Cui, Yuxin; Wang, Qinmei; Hu, Liang

    2016-01-01

    To investigate the correlations between corneal sensation, tear meniscus volume, and tear film osmolarity after femtosecond laser-assisted LASIK (FS-LASIK) surgery. In this prospective clinical study, 31 patients undergoing FS-LASIK for myopia were recruited. The upper and lower tear meniscus volumes (UTMV and LTMV) were measured by customized anterior segment optical coherence tomography, tear film osmolarity was measured by a TearLab Osmolarity test device, central corneal sensation was measured by a Cochet-Bonner esthesiometer preoperatively, at 1 week, 1 and 3 months postoperatively. Repeated measures analysis of variance was used to evaluate whether the tear film osmolarity, tear meniscus volume, and corneal sensation were changed after surgery. The correlations between these variables were analyzed by the Pearson correlation analysis. The tear film osmolarity was (310.03 ± 16.48) mOsms/L preoperatively, (323.51 ± 15.92) mOsms/L at 1 week, (319.93 ± 14.27) mOsms/L at 1 month, and (314.97±12.91) mOsms/L at 3 months. The UTMV was (0.42±0.15), (0.25± 0.09), (0.30±0.11), and (0.35±0.09) μL, respectively; the LTMV was (0.60±0.21),(0.37±0.08), (0.44± 0.14), and (0.52±0.17) μL, respectively. The tear film osmolarity was significantly higher at 1 week and 1 month postoperatively compared with the baseline (P=0.001, 0.004), and reduced to the preoperative level at 3 months (P=0.573). The UTMV, LTMV, and corneal sensation values presented significant decreases at all postoperative time points (all P<0.05). The Pearson correlation analysis showed the postoperative UTMV had a weak relationship with corneal sensation at 1 week after surgery (r=0.356,P=0.005). There were significant correlations between the preoperative LTMV and corneal sensation at 1 week, 1 and 3 months (respectively, r=0.422, 0.366, 0.352;P=0.001, 0.004, 0.006). No significant correlations were found between the tear film osmolarity, tear meniscus volume, and corneal sensation after surgery (all P>0.05). The tear film osmolarity, tear meniscus volume, and corneal sensation became aggravated due to the FS-LASIK surgery procedures. There were significant correlations between the preoperative tear meniscus volume and recovery of corneal sensation early after surgery. A higher tear meniscus volume before surgery may contribute to a faster corneal sensation recovery.

  18. Status of the contralateral rotator cuff in patients undergoing rotator cuff repair.

    PubMed

    Ro, Kyung-Han; Park, Jong-Hoon; Lee, Soon-Hyuck; Song, Dong-Ik; Jeong, Ha-Joon; Jeong, Woong-Kyo

    2015-05-01

    Although the prevalence of rotator cuff tear (RCT) in the general population has been analyzed, little information is available on the status of the opposite-side rotator cuff in patients who have undergone arthroscopic rotator cuff repair. To identify the characteristics of the contralateral shoulder and to identify factors associated with RCT of the contralateral shoulder in patients who underwent surgery for symptomatic RCT. The hypothesis was that the prevalence of RCT in the contralateral shoulder would be higher in patients with increasingly larger cuff tears requiring surgical intervention. Case series; Level of evidence, 4. The study cohort consisted of 140 patients with RCT who underwent arthroscopic rotator cuff repair. Opposite-shoulder rotator cuff tendons of all patients were evaluated by ultrasonography. Demographic information and factors related to contralateral RCT were investigated, and risk factors associated with contralateral RCT were assessed. Of the 140 patients who underwent arthroscopic rotator cuff repair, 54 (38.6%) had an RCT of the contralateral shoulder. Of 51 patients with partial-thickness and small-sized full-thickness tears of the operated shoulder, 35 (68.6%) had no tears; 14 (27.5%) had partial-thickness tears; and 2 (3.9%) had small-sized full-thickness tears of the contralateral shoulder. Of 75 patients with medium-sized full-thickness tears, 43 (57.3%) had no tears; 12 (16%) had partial-thickness tears; and 20 (26.7%) had full-thickness tears of the contralateral shoulder. Of 14 patients with large to massive full-thickness tears, 8 (57.1%) had no tears; 1 (7.1%) had a partial-thickness tear; and 5 (35.7%) had full-thickness tears of the contralateral shoulder. The prevalence of RCT of the contralateral shoulder differed significantly among groups classified by tear size (P=.007). The mean American Shoulder and Elbow Surgeons score was significantly lower in the RCT than in the nontear group (55.8±16.9 vs 61.6±13.3; P=.03). Of 29 subjects with symptomatic tears involving the nondominant arm, 17 (58.6%) had contralateral asymptomatic RCT, compared with 37 of 111 (33.3%) subjects with symptomatic tears involving the dominant arm (P=.007). The prevalence of RCT of the contralateral asymptomatic shoulder tends to be higher in patients with more symptomatic RCT on one side, in patients with medium-sized or larger RCT in the operated shoulder, and in patients with symptomatic RCT in the nondominant arm. © 2015 The Author(s).

  19. Oxygen-deficient metabolism and corneal edema

    PubMed Central

    Leung, B.K.; Bonanno, J.A.; Radke, C.J.

    2014-01-01

    Wear of low-oxygen-transmissible soft contact lenses swells the cornea significantly, even during open eye. Although oxygen-deficient corneal edema is well-documented, a self-consistent quantitative prediction based on the underlying metabolic reactions is not available. We present a biochemical description of the human cornea that quantifies hypoxic swelling through the coupled transport of water, salt, and respiratory metabolites. Aerobic and anaerobic consumption of glucose, as well as acidosis and pH buffering, are incorporated in a seven-layer corneal model (anterior chamber, endothelium, stroma, epithelium, postlens tear film, contact lens, and prelens tear film). Corneal swelling is predicted from coupled transport of water, dissolved salts, and especially metabolites, along with membrane-transport resistances at the endothelium and epithelium. At the endothelium, the Na+/K+ - ATPase electrogenic channel actively transports bicarbonate ion from the stroma into the anterior chamber. As captured by the Kedem–Katchalsky membrane-transport formalism, the active bicarbonate-ion flux provides the driving force for corneal fluid pump-out needed to match the leak-in tendency of the stroma. Increased lactate-ion production during hypoxia osmotically lowers the pump-out rate requiring the stroma to swell to higher water content. Concentration profiles are predicted for glucose, water, oxygen, carbon dioxide, and hydronium, lactate, bicarbonate, sodium, and chloride ions, along with electrostatic potential and pressure profiles. Although the active bicarbonate-ion pump at the endothelium drives bicarbonate into the aqueous humor, we find a net flux of bicarbonate ion into the cornea that safeguards against acidosis. For the first time, we predict corneal swelling upon soft-contact-lens wear from fundamental biophysico-chemical principles. We also successfully predict that hypertonic tear alleviates contact-lens-induced edema. PMID:21820076

  20. Oxygen-deficient metabolism and corneal edema.

    PubMed

    Leung, B K; Bonanno, J A; Radke, C J

    2011-11-01

    Wear of low-oxygen-transmissible soft contact lenses swells the cornea significantly, even during open eye. Although oxygen-deficient corneal edema is well-documented, a self-consistent quantitative prediction based on the underlying metabolic reactions is not available. We present a biochemical description of the human cornea that quantifies hypoxic swelling through the coupled transport of water, salt, and respiratory metabolites. Aerobic and anaerobic consumption of glucose, as well as acidosis and pH buffering, are incorporated in a seven-layer corneal model (anterior chamber, endothelium, stroma, epithelium, postlens tear film, contact lens, and prelens tear film). Corneal swelling is predicted from coupled transport of water, dissolved salts, and especially metabolites, along with membrane-transport resistances at the endothelium and epithelium. At the endothelium, the Na+/K+ - ATPase electrogenic channel actively transports bicarbonate ion from the stroma into the anterior chamber. As captured by the Kedem-Katchalsky membrane-transport formalism, the active bicarbonate-ion flux provides the driving force for corneal fluid pump-out needed to match the leak-in tendency of the stroma. Increased lactate-ion production during hypoxia osmotically lowers the pump-out rate requiring the stroma to swell to higher water content. Concentration profiles are predicted for glucose, water, oxygen, carbon dioxide, and hydronium, lactate, bicarbonate, sodium, and chloride ions, along with electrostatic potential and pressure profiles. Although the active bicarbonate-ion pump at the endothelium drives bicarbonate into the aqueous humor, we find a net flux of bicarbonate ion into the cornea that safeguards against acidosis. For the first time, we predict corneal swelling upon soft-contact-lens wear from fundamental biophysico-chemical principles. We also successfully predict that hypertonic tear alleviates contact-lens-induced edema. Copyright © 2011 Elsevier Ltd. All rights reserved.

  1. Evaluating the efficacy of epinastine ophthalmic solution using a conjunctivitis allergen challenge model in patients with birch pollen allergic conjunctivitis.

    PubMed

    Tagawa, Yoshiaki; Namba, Kenichi; Nakazono, Yumi; Iwata, Daiju; Ishida, Susumu

    2017-04-01

    The efficacy of epinastine 0.05% ophthalmic solution for pollen allergic conjunctivitis has already been shown in a conjunctival allergen challenge (CAC) test using cedar pollen as a challenge. The present study investigated the efficacy of this solution against birch pollen conjunctivitis in a CAC test. Ten adult subjects (eight males and two females) with asymptomatic birch pollen conjunctivitis were enrolled in this study. The average age of the subjects was 41.1 years. This study was conducted during a period without birch pollen dispersion. In each subject, the epinastine 0.05% ophthalmic solution was instilled in one eye, and an artificial tear fluid was instilled in the fellow eye in a double-blind manner. Five minutes or 4 h after the drug instillation, both eyes were challenged with an optimal concentration of birch pollen, and ocular itching and conjunctival hyperemia were then graded. Tears were collected before the drug instillation and 20 min after the pollen challenge, and the histamine level was measured. The ocular itching scores and palpebral conjunctival hyperemia scores of the epinastine-treated eyes were significantly lower than those of the contralateral control eyes when the eyes were pretreated with the drug 4 h before the CAC. There was a significant correlation between the tear histamine level and mean ocular itching score of three time points (3, 5 and 10 min) following the CAC in the control eyes but not the epinastine-treated eyes. Epinastine is effective in suppressing ocular itching and conjunctival hyperemia in birch pollen conjunctivitis. Copyright © 2017 Japanese Society of Allergology. Production and hosting by Elsevier B.V. All rights reserved.

  2. Earlier therapeutic effects associated with high dose (2.0 mg) Ranibizumab for treatment of vascularized pigment epithelial detachments in age-related macular degeneration

    PubMed Central

    Chan, C K; Abraham, P; Sarraf, D; Nuthi, A S D; Lin, S G; McCannel, C A

    2015-01-01

    Summary statement Intravitreal high dose (2 mg) ranibizumab may lead to quicker resolution of choroidal neovascularization (CNV) and associated retinal pigment epithelial detachment in eyes with exudative age-related macular degeneration, although it may possibly correlate with RPE tears in certain cases. Purpose This prospective study compared the outcomes of 0.5 vs 2.0 mg intravitreal ranibizumab injections (RI) for treating vascularized pigment epithelial detachment (vPED) due to age-related macular degeneration. Methods Patients with vPED were randomized to receive 2.0 vs 0.5 mg RI monthly for 12 months or for 4 months and then repeated on a pro-re nata basis. Optical coherence tomography, fundus photography, and fluorescein and indocyanine-green angiography were obtained at baseline and subsequent specific intervals. Outcome measures were best-corrected standardized visual acuities, central 1-mm thickness, surface area (SA), greatest linear diameter (GLD), heights (PED and CNV), and amount of subretinal fluid (SRF) and cystoid macular edema (CME). Results Both groups yielded reductions of the central 1-mm thickness, PED and CNV SA and PED height and GLD, SRF, and CME. Vision improvement and reduction in SRF and PED height occurred earlier for eyes receiving the 2.0 mg dose. Cataract progression was similar but RPE tears developed more often with the 2.0 mg dose. Conclusions There were similar visual and anatomical outcomes at the end of the study; however, the higher dose yielded more rapid reductions and more complete resolution of the PED, although there was possible increased tendency for an RPE tear with the higher dose. PMID:25277305

  3. Effect of rebamipide ophthalmic suspension on signs and symptoms of keratoconjunctivitis sicca in Sjögren syndrome patients with or without punctal occlusions.

    PubMed

    Arimoto, Atsushi; Kitagawa, Kazuko; Mita, Norihiro; Takahashi, Yoriko; Shibuya, Eri; Sasaki, Hiroshi

    2014-08-01

    The aim of this study was to investigate the efficacy of 2% rebamipide suspension in treatment of keratoconjunctivitis sicca (KCS) in patients with Sjögren syndrome (SS) with or without punctal occlusions. Thirty patients with SS, diagnosed based on the presence of autoantibodies and/or focus score >1 on lip biopsies, with corneal fluorescein staining scores (FSS) >3, and conjunctival lissamine green-staining scores (LSS) >3, were treated 4 times daily for 4 weeks with 2% rebamipide ocular suspension. Ocular examinations were performed before treatment and 2 and 4 weeks after treatment to evaluate FSS (0-9), LSS (0-6), and tear film break-up time (BUT). Hyaluronate and/or artificial tears were not discontinued. The patients were interviewed regarding the 5 major KCS symptoms, foreign body sensation, dry eye sensation, photophobia, ocular pain, and blurred vision, with each graded from none (0) to very severe (4). Of the 30 patients, 3 failed to attend all sessions, leaving 27 (25 females, 2 males, mean age 62.5 ± 10.8 years) to be studied. FSS and LSS showed improvement at week 2, but BUT showed improvement later, at week 4. All 5 symptoms improved significantly. When the patients were divided into 3 groups according to the presence of punctal occlusions, FSS and LSS were found to improve in all groups, but BUT improved only in patients with both puncta occluded at week 4. Rebamipide ophthalmic suspension was effective in treating KCS of patients with SS, probably by increasing mucins and suppressing inflammatory cytokines. Punctal occlusions resulted in sufficient retention of tear fluid to enhance the activities of rebamipide and improve BUT.

  4. Outcome of external dacryocystorhinostomy in Ethiopian patients.

    PubMed

    Mekonnen, Worku; Adamu, Yilikal

    2009-07-01

    An imbalance between tear production and drainage results in epiphora, which is an annoying symptom embarrassing the patient socially and functionally. The two widely accepted modalities of treatment for nasolacrimal duct obstruction (NLDO) are external dacryocystorhinostomy (EDCR) and endoscopic dacryocystorhinostomy. EDCR is the mainstay of treatment of NLDO and it remains to be the gold standard with which all other methods must be compared. To determine the outcome of EDCR in Menelik II hospital, Addis Ababa, Ethiopia. The study was also intended to give a baseline data at a tertiary eye care center. A prospective study was done in Menelik II Hospital. All patients scheduled for EDCR between June 2005 and May 2006 were included in the study. EDCR was done for all our cases. Success was defined by patient satisfaction (no complaint of tearing) supported by examination for regurgitation of fluid on pressing the lacrimal sac; and slit lamp assessment for increased tear meniscus. One hundred and twenty eight eyes of 106 patients were included in the study, 36 (34%) were males and 70 (66%) were females. The male to female ratio was approximately 1:2. The commonest indication for dacryocystorhinostomy was chronic dacryocystitis 93 (72.7%). Patients were followed postoperatively for a mean follow up period of 9.3 months (6-12 months). Success was recorded in 119 (93%) of operated eyes. Patients graded incision scar as excellent in 107 (83.6%) eyes, good in 9 (14.8%) and bad in 2 (1.6%) eyes. All patients respond that they would recommend operation for others. The success rate of EDCR in our set up is comparable to studies done in other parts of the world and EDCR is a very effective surgical procedure for our patients with NLDO.

  5. Thermal Analysis System

    NASA Technical Reports Server (NTRS)

    DiStefano, III, Frank James (Inventor); Wobick, Craig A. (Inventor); Chapman, Kirt Auldwin (Inventor); McCloud, Peter L. (Inventor)

    2014-01-01

    A thermal fluid system modeler including a plurality of individual components. A solution vector is configured and ordered as a function of one or more inlet dependencies of the plurality of individual components. A fluid flow simulator simulates thermal energy being communicated with the flowing fluid and between first and second components of the plurality of individual components. The simulation extends from an initial time to a later time step and bounds heat transfer to be substantially between the flowing fluid, walls of tubes formed in each of the individual components of the plurality, and between adjacent tubes. Component parameters of the solution vector are updated with simulation results for each of the plurality of individual components of the simulation.

  6. Numerical Temperature And Fluid-Flow Modelling For The Topographic Effects On Hydrothermal Circulation; A case study in Lucy Strike Vent Field

    NASA Astrophysics Data System (ADS)

    Erçetin, Engin; Düşünür Doǧan, Doǧa

    2017-04-01

    The aim of the study is to present a numerical temperature and fluid-flow modelling for the topographic effects on hydrothermal circulation. Bathymetry can create a major disturbance on fluid flow pattern. ANSYS Fluent Computational fluid dynamics software is used for simulations. Coupled fluid flow and temperature quations are solved using a 2-Dimensional control volume finite difference approach. Darcy's law is assumed to hold, the fluid is considered to be anormal Boussinesq incompressible fluid neglecting inertial effects. Several topographic models were simulated and both temperature and fluid flow calculations obtained for this study. The preliminary simulations examine the effect of a ingle bathymetric high on a single plume and the secondary study of simulations investigates the effect of multiple bathymetric highs on multiple plume. The simulations were also performed for the slow spreading Lucky Strike segment along the Mid-Atlantic Ridge (MAR), one of the best studied regions along the MAR, where a 3.4 km deep magma chamber extending 6 km along-axis is found at its center. The Lucky Strike segment displays a transitional morphology between that of the FAMOUS - North FAMOUS segments, which are characterized by well-developed axial valleys typical of slow-spreading segments, and that of the Menez Gwen segment, characterized by an axial high at the segment center. Lucky Strike Segment hosts a central volcano and active vent field located at the segment center and thus constitutes an excellent case study to simulate the effects of bathymetry on fluid flow. Results demonstrate that bathymetric relief has an important influence on hydrothermal flow. Subsurface pressure alterations can be formed by bathymetric highs, for this reason, bathymetric relief ought to be considered while simulating hydrothermal circulation systems. Results of this study suggest the dominant effect of bathymetric highs on fluid flow pattern and Darcy velocities will be presented. Keywords: Hydrothermal Circulation, Lucky Strike, Bathymetry - Topography, Vent Location, Fluid Flow, Numerical Modelling

  7. Fluid Structural Analysis of Human Cerebral Aneurysm Using Their Own Wall Mechanical Properties

    PubMed Central

    Valencia, Alvaro; Burdiles, Patricio; Ignat, Miguel; Mura, Jorge; Rivera, Rodrigo; Sordo, Juan

    2013-01-01

    Computational Structural Dynamics (CSD) simulations, Computational Fluid Dynamics (CFD) simulation, and Fluid Structure Interaction (FSI) simulations were carried out in an anatomically realistic model of a saccular cerebral aneurysm with the objective of quantifying the effects of type of simulation on principal fluid and solid mechanics results. Eight CSD simulations, one CFD simulation, and four FSI simulations were made. The results allowed the study of the influence of the type of material elements in the solid, the aneurism's wall thickness, and the type of simulation on the modeling of a human cerebral aneurysm. The simulations use their own wall mechanical properties of the aneurysm. The more complex simulation was the FSI simulation completely coupled with hyperelastic Mooney-Rivlin material, normal internal pressure, and normal variable thickness. The FSI simulation coupled in one direction using hyperelastic Mooney-Rivlin material, normal internal pressure, and normal variable thickness is the one that presents the most similar results with respect to the more complex FSI simulation, requiring one-fourth of the calculation time. PMID:24151523

  8. Response of Metals and Metallic Structures to Dynamic Loading

    DTIC Science & Technology

    1978-05-01

    materials for service by testing under high rates of loading. Impact tests such as the Charpy test, the drop-weight tear test, and the dynamic tear...have clearly shown this for precracked charpy specimens and for the drop-weight tear test. Hence, there is a strong need for additional dynamic...dynamic fracture resistance ( Charpy , dynamic-tear, drop-weight tear test, etc.), normally assures that fracture in dynamically loaded structures is

  9. Interferometer for measuring the dynamic surface topography of a human tear film

    NASA Astrophysics Data System (ADS)

    Primeau, Brian C.; Greivenkamp, John E.

    2012-03-01

    The anterior refracting surface of the eye is the thin tear film that forms on the surface of the cornea. Following a blink, the tear film quickly smoothes and starts to become irregular after 10 seconds. This irregularity can affect comfort and vision quality. An in vivo method of characterizing dynamic tear films has been designed based upon a near-infrared phase-shifting interferometer. This interferometer continuously measures light reflected from the tear film, allowing sub-micron analysis of the dynamic surface topography. Movies showing the tear film behavior can be generated along with quantitative metrics describing changes in the tear film surface. This tear film measurement allows analysis beyond capabilities of typical fluorescein visual inspection or corneal topography and provides better sensitivity and resolution than shearing interferometry methods. The interferometer design is capable of identifying features in the tear film much less than a micron in height with a spatial resolution of about ten microns over a 6 mm diameter. This paper presents the design of the tear film interferometer along with the considerations that must be taken when designing an interferometer for on-eye diagnostics. Discussions include eye movement, design of null optics for a range of ocular geometries, and laser emission limits for on-eye interferometry.

  10. Ocular surface inflammation, and nerve growth factor level in tears in active thyroid-associated ophthalmopathy.

    PubMed

    Yoon, Jin Sook; Choi, Soo Hyun; Lee, Joon H; Lee, Sung Jun; Lee, Sang Yeul

    2010-02-01

    To measure tear nerve growth factor (NGF) concentrations in cases of active thyroid-associated ophthalmopathy (TAO) before and after glucocorticoid treatment, and to correlate NGF levels with disease inflammatory activity and thyroid autoantibody concentration. The study involved 20 patients with active TAO and 20 age- and gender-matched controls. Tear break-up time (BUT) was obtained, the Schirmer test was performed, and tear NGF/total protein ratio was measured in control subjects and patients with active TAO before, and 2 and 4 weeks after, steroid treatment. Tear BUT and Schirmer values significantly increased after 2 and 4 weeks of steroid treatment (p < 0.001 and p = 0.004 respectively). Baseline tear NGF/total protein ratio was higher in patients with active TAO than in control subjects, and the ratio significantly decreased after 2 and 4 weeks of steroid treatment (p < 0.001). Tear NGF/total protein ratio did not correlate with inflammatory activity score, exophthalmos value and thyroid binding inhibiting immunoglobulin (TBII) level (p > 0.05). Tear NGF may have a specific role in ocular surface inflammation, which protects against ocular surface damage in patients with active TAO. Anti-inflammatory treatment significantly reduced the level of NGF in tears, increased tear film stability and production, and decreased congestive symptoms.

  11. Clinical Evaluation of the Root Tear of the Posterior Horn of the Medial Meniscus in Total Knee Arthroplasty for Osteoarthritis.

    PubMed

    Choi, Eui-Sung; Park, Sang-Jun

    2015-06-01

    To investigate the incidence of root tears of the posterior horn of the medial meniscus in total knee replacement arthroplasty for knee osteoarthritis and retrospectively analyze clinical results and factors associated with root tears. There were 197 knees of 140 enrolled patients who had undergone total knee replacement arthroplasty between September 2010 and May 2014. The presence of a root tear of the posterior horn of the medial meniscus was confirmed in all patients. Statistical analysis was performed to investigate the correlation between root tears and the possible factors of meniscal tears including gender, age, severity of symptoms (visual analogue scale [VAS] score and medial joint line tenderness), grade of osteoarthritis (Kellgren-Lawrence grading scale), body mass index (BMI), varus deformity, and mechanical axis deviation. Meniscal tears were observed in 154 knees (78.17%). The root tear had correlation with the severity of osteoarthritis (p<0.05), varus deformity (p<0.05), mechanical axis deviation (p<0.05), and BMI (p<0.05). Factors considered to represent the severity of osteoarthritis were found to be associated with root tears of the medial meniscus posterior horn. Increased BMI seemed to be associated with the increased incidence of root tears of the medial meniscus posterior horn.

  12. A Simulation Program with Latency Exploitation and Node Tearing.

    DTIC Science & Technology

    1985-02-01

    translation table JUNODE is constructed to give the relation between the user-defined node set and the node set used in the pro- gram. The ground node...90, 0, 45 and 80, then, user’s node renumbered node JUNODE table 0(ground) 1 nodplc(IUNODE+1)=O 10 2 ( +2)=10 45 3 ( +3)=45 80 4 ( +4)=80 90 5 ( +5

  13. Does simulated walking cause gapping of meniscal repairs?

    PubMed

    McCulloch, Patrick C; Jones, Hugh L; Hamilton, Kendall; Hogen, Michael G; Gold, Jonathan E; Noble, Philip C

    2016-12-01

    The objective of rehabilitation following meniscal repair is to promote healing by limiting stresses on repairs, while simultaneously preserving muscle strength and joint motion. Both protective protocols limiting weight bearing and accelerated which do not, have shown clinical success. This study assesses the effects of physiologic gait loading on the kinematic behavior of a repaired medial meniscus. The medial menisci of eight fresh cadaveric knees were implanted with arrays of six 0.8-1.0 mm beads. Pneumatic actuators delivered muscle loads and forces on the knee as each specimen was subjected to a simulated stance phase of gait. Meniscus motion was measured at loading response, mid stance, and toe-off positions. Measurements were performed using biplanar radiography and RSA, with each knee: (a) intact, (b) with posterior longitudinal tear, and (c) after inside-out repair. The tissue spanning the site of the longitudinal tear underwent compression rather than gapping open in all states (intact [I], torn [T] and repaired [R] states). Average compression at three sites along the posterior half of the meniscus was: posterior horn -0.20 ± 0.08 mm [I], -0.39 ± 0.10 mm [T], and -0.20 ± 0.06 mm [R] (p = 0.15); junction of posterior horn and body -0.11 ± 0.12 mm [I], -0.21 ± 12 mm [T], -0.17 ± 0.09 mm [R] (p = 0.87); and adjacent to the medial collateral ligament -0.07 ± 0.06 mm [I], -0.29 ± 0.13 mm [T], -0.07 ± 0.17 mm [R] (p = 0.35). The entire meniscus translated posteriorly from mid-stance to toe off. Displacement was greatest in the torn state compared to intact, but was not restored to normal levels after repair. The edges of a repaired longitudinal medial meniscal tear undergo compression, not gapping, during simulated gait.

  14. Reduced tear production in three canine endocrinopathies.

    PubMed

    Williams, D L; Pierce, V; Mellor, P; Heath, M F

    2007-05-01

    Previous reports have suggested that hypothyroid and diabetic patients can be predisposed to keratoconjunctivitis sicca. This study aimed to measure tear production in dogs with diabetes, hypothyroidism and hyperadrenocorticism using the Schirmer tear test and to compare these results with Schirmer tear test values for a group of normal dogs. Schirmer tear tests were performed on 16 dogs with hyperadrenocorticism, 18 with diabetes and 12 with hypothyroidism together with 100 control dogs. Corneal sensitivity was also measured in 12 of the 18 diabetic dogs with a Cochet Bonnet aesthesiometer and compared with age- and breed-matched normal dogs. Schirmer tear test values in dogs with hypothyroidism, hyperadrenocorticism and diabetes were 12.3+/-3.2, 14.0+/-4.0 and 12.3+/-5.3 mm/minutes, respectively. Schirmer tear test values were significantly lower than that for the control group (19.6+/-4.2 mm/minutes) in all dogs with an endocrinopathy. Only in two hypothyroid dogs and three diabetics, this was manifested as profound keratoconjunctivitis sicca with Schirmer tear test value lower than 5 mm/minutes. Diabetic dogs had significantly reduced corneal sensitivity compared with a matched set of control dogs. This study shows a significant reduction in tear production in animals with diabetes mellitus, hypothyroidism and hyperadrenocorticism. Further research is needed to elucidate the mechanisms by which this reduction in tear production occurs. Assessment of tear production should be undertaken in animals diagnosed with these endocrinopathies, as these animals may progress to clinical keratoconjunctivitis sicca.

  15. Diadenosine tetraphosphate contributes to carbachol-induced tear secretion.

    PubMed

    Fonseca, Begoña; Martínez-Águila, Alejandro; Díaz-Hernández, Miguel; Pintor, Jesús

    2015-03-01

    The purpose of this study is to investigate if the cholinergic stimulation by carbachol on tear secretion is a direct process or if it is also mediated by purinergic mechanisms. Experiments were performed in New Zealand male rabbits. The amount of tear secretion was measured with Schirmer's test and then analyzed by a HPLC protocol in order to study the nucleotide levels. Animal eyes were instilled with carbachol (a cholinergic agonist), pirenzepine, gallamine and 4-DAMP (muscarinic antagonists), PPADS, suramin and reactive blue 2 (purinergic antagonists), and a P2Y2 receptor small interfering RNA (siRNA). Tear secretion increased with the instillation of carbachol, approximately 84 % over control values 20 min after the instillation and so did Ap4A and ATP release. When we applied carbachol in the presence of muscarinic antagonists, tear volume only increased to 4 % with atropine, 12 % in the case of pirenzepine, 3 % with gallamine, and 8 % with 4-DAMP. In the presence of carbachol and purinergic antagonists, tear secretion was increased to 12 % (all values compared to basal tear secretion). By analyzing tear secretion induced with carbachol in presence of a P2Y2 receptor siRNA, we found that tear secretion was diminished to 60 %. The inhibition of tear secretion in the presence of carbachol and purinergic antagonists or P2Y2 siRNA occurred with no apparent change in the tear amount of Ap4A. These experiments demonstrated the participation of Ap4A in lacrimal secretion process.

  16. Evaluation of cartilage degeneration in a rat model of rotator cuff tear arthropathy

    PubMed Central

    Kramer, Erik J.; Bodendorfer, Blake M.; Laron, Dominique; Wong, Jason; Kim, Hubert T.; Liu, Xuhui; Feeley, Brian T.

    2013-01-01

    Introduction Rotator cuff tears are the most common injury seen by shoulder surgeons. Many late stage rotator cuff tear patients develop glenohumeral osteoarthritis as a result of torn cuff tendons, termed cuff tear arthropathy. However, the mechanisms of cuff tear arthropathy have not been fully established. It has been hypothesized that a combination of synovial and mechanical factors contribute equally to the development of cuff tear arthropathy. The goal of this study was to assess the utility of this model in investigating cuff-tear arthropathy. Methods We utilized a rat model which accurately reflects rotator cuff muscle degradation after massive rotator cuff tears through either infraspinatus and supraspinatus tenotomy or suprascapular nerve transection. Using a Modified-Mankin Scoring System (MMS), we found significant glenohumeral cartilage damage following both rotator cuff tenotomy and suprascapular nerve transection after only 12 weeks. Results Cartilage degeneration was similar between groups, and was present on both the humeral head and the glenoid. Denervation of the supraspinatus and infraspinatus muscles without opening the joint capsule caused cartilage degeneration similar to that found in the tendon transection group. Conclusions These results suggest that altered mechanical loading after rotator cuff tears is the primary factor in cartilage degeneration after rotator cuff tears. Clinically, understanding the process of cartilage degeneration after rotator cuff injury will help guide treatment decisions in the setting of rotator cuff tears. Level of evidence Basic Science Study, Animal Model PMID:23664745

  17. A review of patient and skin characteristics associated with skin tears.

    PubMed

    Rayner, R; Carville, K; Leslie, G; Roberts, P

    2015-09-01

    Skin tears are the most common wound among the elderly and have the potential to cause infection, form chronic wounds, reduce quality of life and increase health-care costs. Our aim was to identify studies that reviewed patient and skin characteristics associated with skin tears. A review of skin tear studies reported in the English literature between 1980 and 2013 was undertaken using the following electronic databases: PubMed, Medline, CINAHL, Embase, Scopus, Evidence Based and Medicine Reviews (EBM). Search terms included aged, skin, tears or lacerations, skin tearing, geri tear, epidermal tear and prevalence. There were 343 articles found with using the search terms. After abstract review nine were found to be relevant to the search. The principle findings from these eight published articles and one unpublished study revealed that the most common patient characteristics were a history of skin tears, impaired mobility and impaired cognition. Skin characteristics associated with skin tears included senile purpura, ecchymosis and oedema. This review provides an overview of identified patient and skin characteristics that predispose the elderly to skin tears and exposes the lack of research within this domain. R. Rayner is a recipient of a 2013 Australian Postgraduate Award, Curtin University Postgraduate Scholarship and a Wound Management Cooperative Research Centre (CRC) PhD stipend. The School of Nursing, Midwifery and Paramedicine, Curtin University and the Silver Chain Group, Western Australia are participants in the Wound Management Innovation CRC. No conflict of interest exists among the authors.

  18. Blast and the Consequences on Traumatic Brain Injury-Multiscale Mechanical Modeling of Brain

    DTIC Science & Technology

    2011-02-17

    blast simulation. LS-DYNA as an explicit FE code has been employed to simulate this multi- material fluid –structure interaction problem. The 3-D head...formulation is implemented to model the air-blast simulation. LS-DYNA as an explicit FE code has been employed to simulate this multi-material fluid ...Biomechanics Study of Influencing Parameters for brain under Impact ............................... 12 5.1 The Impact of Cerebrospinal Fluid

  19. Neurostimulation of the Lacrimal Nerve for Enhanced Tear Production

    PubMed Central

    Kossler, Andrea L.; Wang, Jianhua; Feuer, William; Tse, David T.

    2014-01-01

    Purpose To design a proof-of-concept study to assess the effect of lacrimal nerve stimulation (LNS) with an implantable pulse generator (IPG) to increase aqueous tear production. Methods Experimental animal study design of six Dutch Belted rabbits. Ultra high-resolution optical coherence tomography (UHR-OCT) quantified tear production by measuring the baseline tear volume of each rabbit’s right and left eye. A neurostimulator was implanted adjacent to the right lacrimal nerve. After two minutes of LNS (100 μs, 1.6 mAmp, 20 Hz, 5–8 volts), the tear volumes were measured with UHR-OCT. The change in tear volume was quantified and compared to the non-stimulated left eye. Three rabbits underwent chronic LNS (100 μS, 1.6 mAmp, 10 Hz, 2 volts) and their lacrimal glands were harvested for histopathologic analysis. Results UHR-OCT imaging of the right eyes tear volume showed a 441% average increase in tear production after LNS as a percent of baseline. After stimulation, right eyes had statistically significant greater increase in tear volumes than left eyes (p=0.028, Wilcoxon test). Post-stimulation right eye tear volumes were significantly greater compared to baseline (p=0.028, Wilcoxon test). Histopathologic examination of the lacrimal glands showed no discernible tissue damage from chronic neurostimulation. Additionally, there were no gross adverse effects on the general well-beings of the animals due to chronic stimulation. Conclusions Lacrimal nerve stimulation with an implantable pulse generator appears to increase aqueous tear production. Chronic LNS showed no histopathologic lacrimal gland damage. This study suggests LNS is a promising new treatment strategy to increase aqueous tear production. PMID:25126767

  20. Identification and Comparison of the Polar Phospholipids in Normal and Dry Eye Rabbit Tears by MALDI-TOF Mass Spectrometry

    PubMed Central

    Ham, Bryan M.; Cole, Richard B.; Jacob, Jean T.

    2008-01-01

    Purpose To identify and compare the phosphorylated lipids in normal and dry eye rabbit tears using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS). Methods MALDI-TOF MS studies were performed on tear samples from normal and dry eyes of female New Zealand White rabbits. Experimental dry eye was induced by complete removal of the main and accessory lacrimal glands and nictitating membranes. A solid ionic crystal MALDI matrix of paranitroaniline and butyric acid was used to enhance the mass spectral responses of the phospholipids. In addition, a novel lipid isolation, preconcentration, and clean-up method using pipettes containing immobilized metal ion affinity chromatography (IMAC) medium was used. Results The polar phospholipids present in the normal and dry eye rabbit tears showed both similarities and differences. Species related to platelet-activating factor (PAF) and/or lysophosphatidylcholine (lyso-PC), phosphatidylcholine (PC), and sphingomyelin (SM) were found in both the normal and dry eye rabbit tears. However, the number of types and the concentrations of SM molecules were markedly greater in the dry eye tears than in the normal tears. In addition, phosphatidylserine (PS) species that were readily detectable in dry eye tears were not found in normal tears. Conclusions The combination of immobilized metal ion affinity chromatography and the solid ionic crystal matrix for MALDI enabled the detection and study of phosphorylated lipids in the tears. Specific differences between phospholipid levels in normal and dry eye tears were observable with this methodology. The appearance of various SM species only in the dry eye tears may provide markers for this disease state in the future. PMID:16877399

Top