Activation of the hip adductor muscles varies during a simulated weight-bearing task.
Hides, Julie A; Beall, Paula; Franettovich Smith, Melinda M; Stanton, Warren; Miokovic, Tanja; Richardson, Carolyn
2016-01-01
To investigate the pattern of muscle activation of the individual hip adductor muscles using a standardised simulated unilateral weight-bearing task. A repeated measures design. Laboratory. 20 healthy individuals (11 females, 9 males) participated in the study. Age ranged from 20 to 25 years. Surface electromyography recordings from adductor magnus and adductor longus muscles were taken at levels representing 10-50% of body weight during a simulated weight-bearing task. Electromyography (EMG) data were normalised to maximal voluntary isometric contraction. The adductor magnus was recruited at significantly higher levels than the adductor longus muscle during a simulated weight-bearing task performed across 10-50% of body weight (p < 0.01). Adductor magnus and adductor longus muscles are recruited to different extents during a simulated weight-bearing task. This information should be considered when selecting exercises for management and prevention of groin strains. Closed chain exercises with weight-bearing through the lower limb are more likely to recruit the adductor magnus muscle over the adductor longus muscle. Copyright © 2015 Elsevier Ltd. All rights reserved.
Hides, Julie A; Belavý, Daniel L; Cassar, Lana; Williams, Michelle; Wilson, Stephen J; Richardson, Carolyn A
2009-03-01
An important aspect of neuromuscular control at the lumbo-pelvic region is stabilization. Subjects with low back pain (LBP) have been shown to exhibit impairments in motor control of key muscles which contribute to stabilization of the lumbo-pelvic region. However, a test of automatic recruitment that relates to function has been lacking. A previous study used ultrasound imaging to show that healthy subjects automatically recruited the transversus abdominis (TrA) and internal oblique (IO) muscles in response to a simulated weight-bearing task. This task has not been investigated in subjects with LBP. The aim of this study was to compare the automatic recruitment of the abdominal muscles among subjects with and without LBP in response to the simulated weight-bearing task. Twenty subjects with and without LBP were tested. Real-time ultrasound imaging was used to assess changes in thickness of the TrA and internal oblique IO muscles as well as lateral movement ("slide") of the anterior fascial insertion of the TrA muscle. Results showed that subjects with LBP showed significantly less shortening of the TrA muscle (P < 0.0001) and greater increases in thickness of the IO muscle (P = 0.002) with the simulated weight-bearing task. There was no significant difference between groups for changes in TrA muscle thickness (P = 0.055). This study provides evidence of changes in motor control of the abdominal muscles in subjects with LBP. This test may provide a functionally relevant and non-invasive method to investigate the automatic recruitment of the abdominal muscles in people with and without LBP.
Hyde, Jodie; Stanton, Warren R; Hides, Julie A
2012-02-01
The aim of this study was to examine the automatic recruitment of the deep abdominal muscles during a unilateral simulated weight-bearing task by elite Australian Rules football (AFL) players with and without low back pain (LBP). An observational cross-sectional study was conducted using ultrasound imaging to measure the thickness of the internal oblique (IO) and transversus abdominis (TrA) muscles. Thirty-seven elite male AFL players participated. Repeated measures factors included 'force level' (rest, 25% and 45% of body weight), 'leg' (dominant or non-dominant kicking leg) and 'side' (ultrasound side ipsilateral or contralateral to the leg used for the weight-bearing task). The dependent variables were thickness of the IO and TrA muscles. The results of this study showed that thickness of the IO (p<.0001) and TrA (p<.0001) muscles increased in response to 'force level'. During the task, the thickness of the IO muscle on the contralateral side of the trunk relative to the leg being tested, increased more in participants with current LBP (p=.034). This pattern was more distinct on the non-dominant kicking leg. Altered abdominal muscle recruitment in elite athletes with low back pain may be an attempt by the central nervous system (CNS) to compensate for inadequate lumbo-pelvic stability. Copyright © 2011 Elsevier B.V. All rights reserved.
Cronström, Anna; Creaby, Mark W; Nae, Jenny; Ageberg, Eva
2016-09-01
Increased knee abduction during weight-bearing activities is suggested to be a contributing factor for the high knee injury risk reported in women. However, studies investigating gender difference in knee abduction are inconclusive. To systematically review gender-differences in knee abduction during weight-bearing activities in individuals with or without knee injury. A systematic review and meta-analysis were conducted according to the PRISMA guidelines. A search in the databases Medline, CINAHL and EMBASE was performed until September 2015. Inclusion criteria were studies that reported (1) gender differences, (2) healthy individuals and/or those with anterior cruciate ligament (ACL) deficiency or reconstruction or patellofemoral pain PFP, and (3) knee abduction assessed with either motion analysis or visual observation during weight-bearing activity. Fifty-eight articles met the inclusion criteria. Women with PFP had greater peak knee abduction compared to men (Std diff in mean; -1.34, 95%CI; -1.83 to -0.84). In healthy individuals, women performed weight-bearing tasks with greater knee abduction throughout the movement (initial contact, peak abduction, excursion) (Std diff in mean; -0.68 to -0.79, 95%CI; -1.04 to -0.37). In subgroup analyses by task, differences in knee abduction between genders were present for most tasks, including running, jump landings and cutting movements. There were too few studies in individuals with ACL injury to perform meta-analysis. The gender difference in knee abduction during weight-bearing activities should be considered in training programs aimed at preventing or treating knee injury. Copyright © 2016 Elsevier B.V. All rights reserved.
Hides, Julie A; Endicott, Timothy; Mendis, M Dilani; Stanton, Warren R
2016-07-01
To investigate whether motor control training alters automatic contraction of abdominal muscles in elite cricketers with low back pain (LBP) during performance of a simulated unilateral weight-bearing task. Clinical trial. 26 male elite-cricketers attended a 13-week cricket training camp. Prior to the camp, participants were allocated to a LBP or asymptomatic group. Real-time ultrasound imaging was used to assess automatic abdominal muscle response to axial loading. During the camp, the LBP group performed a staged motor control training program. Following the camp, the automatic response of the abdominal muscles was re-assessed. At pre-camp assessment, when participants were axially loaded with 25% of their own bodyweight, the LBP group showed a 15.5% thicker internal oblique (IO) muscle compared to the asymptomatic group (p = 0.009). The post-camp assessment showed that participants in the LBP group demonstrated less contraction of the IO muscle in response to axial loading compared with the asymptomatic group. A trend was found in the automatic recruitment pattern of the transversus abdominis (p = 0.08). Motor control training normalized excessive contraction of abdominal muscles in response to a low load task. This may be a useful strategy for rehabilitation of cricketers with LBP. Copyright © 2016 Elsevier Ltd. All rights reserved.
Pivoting neuromuscular control and proprioception in females and males.
Lee, Song Joo; Ren, Yupeng; Kang, Sang Hoon; Geiger, François; Zhang, Li-Qun
2015-04-01
Noncontact ACL injuries occur most commonly in pivoting sports and are much more frequent in females than in males. However, information on sex differences in proprioceptive acuity under weight-bearing and leg neuromuscular control in pivoting is scarce. The objective of this study was to investigate sex differences in pivoting neuromuscular control during strenuous stepping tasks and proprioceptive acuity under weight-bearing. 21 male and 22 female subjects were recruited to evaluate pivoting proprioceptive acuity under weight-bearing, and pivoting neuromuscular control (in terms of leg pivoting instability, stiffness, maximum internal and external pivoting angles, and entropy of time-to-peak EMG in lower limb muscles) during strenuous stepping tasks performed on a novel offaxis elliptical trainer. Compared to males, females had significantly lower proprioceptive acuity under weight-bearing in both internal and external pivoting directions, higher pivoting instability, larger maximum internal pivoting angle, lower leg pivoting stiffness, and higher entropy of time-to-peak EMG in the gastrocnemius muscles during strenuous stepping tasks with internal and external pivoting perturbations. Results of this study may help us better understand factors contributing to ACL injuries in females and males, develop training strategies to improve pivoting neuromuscular control and proprioceptive acuity, and potentially reduce ACL and lower-limb musculoskeletal injuries.
Braun, Benedikt J; Veith, Nils T; Rollmann, Mika; Orth, Marcel; Fritz, Tobias; Herath, Steven C; Holstein, Jörg H; Pohlemann, Tim
2017-08-01
Rehabilitation after lower-extremity fractures is based on the physicians' recommendation for non-, partial-, or full weight-bearing. Clinical studies rely on this assumption, but continuous compliance or objective loading rates are unknown. The purpose of this study was to determine the compliance to weight-bearing recommendations by introducing a novel, pedobarography system continuously registering postoperative ground forces into ankle, tibial shaft and proximal femur fracture aftercare and test its feasibility for this purpose. In this prospective, observational study, a continuously measuring pedobarography insole was placed in the patients shoe during the immediate post-operative aftercare after ankle, tibial shaft and intertrochanteric femur fractures. Weight-bearing was ordered as per the institutional standard and controlled by physical therapy. The insole was retrieved after a maximum of six weeks (28 days [range 5-42 days]). Non-compliance was defined as a failure to maintain, or reach the ordered weight-bearing within 30%. Overall 30 patients were included in the study. Fourteen (47%) of the patients were compliant to the weight-bearing recommendations. Within two weeks after surgery patients deviated from the recommendation by over 50%. Sex, age and weight did not influence the performance (p > 0.05). Ankle fracture patients (partial weight-bearing) showed a significantly increased deviation from the recommendation (p = 0.01). Our study results show that, despite physical therapy training, weight-bearing compliance to recommended limits was low. Adherence to the partial weight-bearing task was further decreased over time. Uncontrolled weight-bearing recommendations should thus be viewed with caution and carefully considered as fiction. The presented insole is feasible to determine weight bearing continuously, could immediately help define real-time patient behaviour and establish realistic, individual weight-bearing recommendations.
Gade, Venkata; Allen, Jerome; Cole, Jeffrey L; Barrance, Peter J
2016-07-01
To characterize the ability of patients with symptomatic knee osteoarthritis (OA) to perform a weight-bearing activity compatible with upright magnetic resonance imaging (MRI) scanning and how this ability is affected by knee pain symptoms and flexion angles. Cross-sectional observational study assessing effects of knee flexion angle, pain level, and study sequence on accuracy and duration of performing a task used in weight-bearing MRI evaluation. Visual feedback of knee position from an MRI compatible sensor was provided. Pain levels were self-reported on a standardized scale. Simulated MRI setup in a research laboratory. Convenience sample of individuals (N=14; 9 women, 5 men; mean, 69±14y) with symptomatic knee OA. Not applicable. Averaged absolute and signed angle error from target knee flexion for each minute of trial and duration tolerance (the duration that subjects maintained position within a prescribed error threshold). Absolute targeting error increased at longer trial durations (P<.001). Duration tolerance decreased with increasing pain (mean ± SE, no pain: 3min 19s±11s; severe pain: 1min 49s±23s; P=.008). Study sequence affected duration tolerance (first knee: 3min 5s±9.1s; second knee: 2min 19s±9.7s; P=.015). The study provided evidence that weight-bearing MRI evaluations based on imaging protocols in the range of 2 to 3 minutes are compatible with patients reporting mild to moderate knee OA-related pain. Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Abujaber, Sumayeh; Gillispie, Gregory; Marmon, Adam; Zeni, Joseph
2015-01-01
Weight bearing asymmetry is common in patients with unilateral lower limb musculoskeletal pathologies. The Nintendo Wii Balance Board (WBB) has been suggested as a low-cost and widely-available tool to measure weight bearing asymmetry in a clinical environment; however no study has evaluated the validity of this tool during dynamic tasks. Therefore, the purpose of this study was to determine the concurrent validity of force measurements acquired from the WBB as compared to laboratory force plates. Thirty-five individuals before, or within 1 year of total joint arthroplasty performed a sit-to-stand and return-to-sit task in two conditions. First, subjects performed the task with both feet placed on a single WBB. Second, the task was repeated with each foot placed on an individual laboratory force plate. Peak vertical ground reaction force (VGRF) under each foot and the inter-limb symmetry ratio were calculated. Validity was examined using Intraclass Correlation Coefficients (ICC), regression analysis, 95% limits of agreement and Bland-Altman plots. Force plates and the WBB exhibited excellent agreement for all outcome measurements (ICC =0.83–0.99). Bland-Altman plots showed no obvious relationship between the difference and the mean for the peak VGRF, but there was a consistent trend in which VGRF on the unaffected side was lower and VGRF on the affected side was higher when using the WBB. However, these consistent biases can be adjusted for by utilizing regression equations that estimate the force plate values based on the WBB force. The WBB may serve as a valid, suitable, and low-cost alternative to expensive, laboratory force plates for measuring weight bearing asymmetry in clinical settings. PMID:25715680
Abujaber, Sumayeh; Gillispie, Gregory; Marmon, Adam; Zeni, Joseph
2015-02-01
Weight bearing asymmetry is common in patients with unilateral lower limb musculoskeletal pathologies. The Nintendo Wii Balance Board (WBB) has been suggested as a low-cost and widely-available tool to measure weight bearing asymmetry in a clinical environment; however no study has evaluated the validity of this tool during dynamic tasks. Therefore, the purpose of this study was to determine the concurrent validity of force measurements acquired from the WBB as compared to laboratory force plates. Thirty-five individuals before, or within 1 year of total joint arthroplasty performed a sit-to-stand and return-to-sit task in two conditions. First, subjects performed the task with both feet placed on a single WBB. Second, the task was repeated with each foot placed on an individual laboratory force plate. Peak vertical ground reaction force (VGRF) under each foot and the inter-limb symmetry ratio were calculated. Validity was examined using Intraclass Correlation Coefficients (ICC), regression analysis, 95% limits of agreement and Bland-Altman plots. Force plates and the WBB exhibited excellent agreement for all outcome measurements (ICC=0.83-0.99). Bland-Altman plots showed no obvious relationship between the difference and the mean for the peak VGRF, but there was a consistent trend in which VGRF on the unaffected side was lower and VGRF on the affected side was higher when using the WBB. However, these consistent biases can be adjusted for by utilizing regression equations that estimate the force plate values based on the WBB force. The WBB may serve as a valid, suitable, and low-cost alternative to expensive, laboratory force plates for measuring weight bearing asymmetry in clinical settings. Copyright © 2015 Elsevier B.V. All rights reserved.
Chen, Weng-Pin; Tai, Ching-Lung; Tan, Chih-Feng; Shih, Chun-Hsiung; Hou, Shun-Hsin; Lee, Mel S
2005-01-01
Transtrochanteric rotational osteotomy is a technical demanding procedure. Currently, the pre-operative planning of the transtrochanteric rotational osteotomy is mostly based on X-ray images. The surgeons would need to reconstruct the three-dimensional structure of the femoral head and the necrosis in their mind. This study develops a simulation platform using computer models based on the computed tomography images of the femoral head to evaluate the degree to which transtrochanteric rotational osteotomy moves the region of osteonecrotic femoral head out of the weight-bearing area in stance and gait cycle conditions. Based on this simulation procedure, the surgeons would be better informed before the surgery and the indication can be carefully assessed. A case with osteonecrosis involving 15% of the femoral head was recruited. Virtual models with the same size lesion but at different locations were devised. Computer models were created using SolidWorks 2000 CAD software. The area ratio of weight-bearing zone occupied by the necrotic lesion on two conditions, stance and gait cycle, were measured after surgery simulations. For the specific case and virtual models devised in this study, computer simulation showed the following two findings: (1) The degrees needed to move the necrosis out of the weight-bearing zone in stance were less by anterior rotational osteotomy as compared to that of posterior rotational osteotomy. However, the necrotic region would still overlap with the weight-bearing area during gait cycle. (2) Because the degrees allowed for posterior rotation were less restricted than anterior rotation, posterior rotational osteotomies were often more effective to move the necrotic region out of the weight-bearing area during gait cycle. The computer simulation platform by registering actual CT images is a useful tool to assess the direction and degrees needed for transtrochanteric rotational osteotomy. Although the results indicated that anterior rotational osteotomy was more effective to move the necrosis out of the weight-bearing zone in stance for models devised in this study, in circumstances where the necrotic region located at various locale, considering the limitation of anterior rotation inherited with the risk of vascular compromise, it might be more beneficial to perform posterior rotation osteotomy in taking account of gait cycle.
Van Rossom, Sam; Wesseling, Mariska; Van Assche, Dieter; Jonkers, Ilse
2018-01-01
Objective Early detection of degenerative changes in the cartilage matrix composition is essential for evaluating early interventions that slow down osteoarthritis (OA) initiation. T1rho and T2 relaxation times were found to be effective for detecting early changes in proteoglycan and collagen content. To use these magnetic resonance imaging (MRI) methods, it is important to document the topographical variation in cartilage thickness, T1rho and T2 relaxation times in a healthy population. As OA is partially mechanically driven, the relation between these MRI-based parameters and localized mechanical loading during walking was investigated. Design MR images were acquired in 14 healthy adults and cartilage thickness and T1rho and T2 relaxation times were determined. Experimental gait data was collected and processed using musculoskeletal modeling to identify weight-bearing zones and estimate the contact force impulse during gait. Variation of the cartilage properties (i.e., thickness, T1rho, and T2) over the femoral cartilage was analyzed and compared between the weight-bearing and non-weight-bearing zone of the medial and lateral condyle as well as the trochlea. Results Medial condyle cartilage thickness was correlated to the contact force impulse ( r = 0.78). Lower T1rho, indicating increased proteoglycan content, was found in the medial weight-bearing zone. T2 was higher in all weight-bearing zones compared with the non-weight-bearing zones, indicating lower relative collagen content. Conclusions The current results suggest that medial condyle cartilage is adapted as a long-term protective response to localized loading during a frequently performed task and that the weight-bearing zone of the medial condyle has superior weight bearing capacities compared with the non-weight-bearing zones.
Demirbüken, İlkşan; Özyürek, Seher; Angın, Salih
2016-12-01
Knee osteoarthritis has commonly been associated with a symptom of pain resulting in an inter-limb weight-bearing asymmetry during functional tasks. Patellar tendon strap is one of the non-pharmacologic interventions to alleviate knee pain. To investigate the immediate effect of a patellar tendon strap on weight-bearing asymmetry during squatting in people with unilateral knee osteoarthritis. Cross-sectional study. Ten patients with unilateral knee osteoarthritis and 10 healthy subjects were included in the study. Weight-bearing asymmetry of patients was assessed using a weight-bearing squat test during squatting at 30° and 60° both with and without patellar tendon strap. Pain intensity was assessed during squatting in unstrapped and strapped conditions with Visual Analog Scale. The decrease in weight-bearing asymmetry values immediately after wearing patellar tendon strap during 30° (p = 0.006) and 60° (p = 0.011) of squatting tests was significantly higher in knee osteoarthritis patients than in healthy subjects. Reported pain intensity was similar in unstrapped and strapped conditions (p = 0.066). The results of this study showed improved inter-limb weight-bearing symmetry during squatting. Further research with larger sample sizes investigating the effect of patellar tendon strap on weight-bearing asymmetry during functional activities in people with knee osteoarthritis is warranted. Patellar tendon straps (easily fit and cheap unlike knee braces) had more improvements in inter-limb weight-bearing symmetry during squatting in people with knee osteoarthritis compared to healthy subjects. This study is a new insight for future studies to investigate clinical benefits of wearing patellar tendon straps in this population. © The International Society for Prosthetics and Orthotics 2015.
Huang, Jerry I; Peterson, Bret; Bellevue, Kate; Lee, Nicolas; Smith, Sean; Herfat, Safa
2017-04-01
The goal of this study was to compare the biomechanical stability of a 2.4-mm dorsal spanning bridge plate with a volar locking plate (VLP) in a distal radius fracture model, during simulated crutch weight-bearing. Five paired cadaveric forearms were tested. A 1-cm dorsal wedge osteotomy was created to simulate an unstable distal radius fracture with dorsal comminution. Fractures were fixed with a VLP or a dorsal bridge plate (DBP). Specimens were mounted to a crutch handle, and optical motion-tracking sensors were attached to the proximal and distal segments. Specimens were loaded in compression at 1 mm/s on a servohydraulic test frame until failure, defined as 2 mm of gap site displacement. The VLP construct was significantly more stable to axial load in a crutch weight-bearing model compared with the DBP plate (VLP: 493 N vs DBP: 332 N). Stiffness was higher in the VLP constructs, but this was not statistically significant (VLP: 51.4 N/mm vs DBP: 32.4 N/mm). With the crutch weight-bearing model, DBP failed consistently with wrist flexion and plate bending, whereas VLP failed with axial compression at the fracture site and dorsal collapse. Dorsal spanning bridge plating is effective as an internal spanning fixator in treating highly comminuted intra-articular distal radius fracture and prevents axial collapse at the radiocarpal joint. However, bridge plating may not offer advantages in early weight-bearing or transfer in polytrauma patients, with less axial stability in our crutch weight-bearing model compared with volar plating. A stiffer 3.5-mm DBP or use of a DBP construct without the central holes may be considered for distal radius fractures if the goal is early crutch weight-bearing through the injured extremity.
NASA Technical Reports Server (NTRS)
Fielder, Paul J.; Morey, Emily R.; Roberts, W. Eugene
1986-01-01
Utilizing the nuclear morphometric assay for osteoblast histogenesis, the effect of simulated weightlessness (SW) on the relative numbers of the periodontal ligament (PDL) osteoblast progenitors and on the total number of osteogenic cells was determined in rats. Weightlessness was simulated by subjecting rats to continuous 30-deg head-down posture using a modified back-harness device of Morey (1979). The response of a partially unloaded, weight-bearing bone, tibial primary spongiosa (PS), was compared to a normally loaded, nonweight-bearing PDL bone. Data indicated a similar differentiation sequence in PS and PDL, which suggests that these bones might be sensitive to the same systemic factors. Preosteoblast numbers were seen to decrease in both nonweight-bearing and weight-bearing bones during SW (compared with rats not exposed to SW), indicating the importance of systemic mediators, such as cephalad fluid shift, physiological stress, and/or growth retardation.
NASA Technical Reports Server (NTRS)
Adams, M. L.; Padovan, J.; Fertis, D. G.
1980-01-01
A general purpose squeeze-film damper interactive force element was developed, coded into a software package (module) and debugged. This software package was applied to nonliner dynamic analyses of some simple rotor systems. Results for pressure distributions show that the long bearing (end sealed) is a stronger bearing as compared to the short bearing as expected. Results of the nonlinear dynamic analysis, using a four degree of freedom simulation model, showed that the orbit of the rotating shaft increases nonlinearity to fill the bearing clearance as the unbalanced weight increases.
Muscle glucose uptake in the rat after suspension with single hindlimb weight bearing
NASA Technical Reports Server (NTRS)
Stump, Craig S.; Woodman, Christopher R.; Fregosi, Ralph F.; Tipton, Charles M.
1993-01-01
An examination is conducted of the effect of nonweight-bearing conditions, and the systemic influences of simulated microgravity on rat hindlimb muscles. The results obtained suggest that the increases in hindlimb muscle glucose uptake and extracellular space associated with simulated microgravity persist with hindlimb weightbearing, despite the prevention of muscle atrophy. The mechanism (or mechanisms) responsible for these effects are currently unknown.
The Effects of Differential Goal Weights on the Performance of a Complex Financial Task.
ERIC Educational Resources Information Center
Edmister, Robert O.; Locke, Edwin A.
1987-01-01
Determined whether people could obtain outcomes on a complex task that would be in line with differential goal weights corresponding to different aspects of the task. Bank lending officers were run through lender-simulation exercises. Five performance goals were weighted. Demonstrated effectiveness of goal setting with complex tasks, using group…
NASA Astrophysics Data System (ADS)
Kerst, Stijn; Shyrokau, Barys; Holweg, Edward
2018-05-01
This paper proposes a novel semi-analytical bearing model addressing flexibility of the bearing outer race structure. It furthermore presents the application of this model in a bearing load condition monitoring approach. The bearing model is developed as current computational low cost bearing models fail to provide an accurate description of the more and more common flexible size and weight optimized bearing designs due to their assumptions of rigidity. In the proposed bearing model raceway flexibility is described by the use of static deformation shapes. The excitation of the deformation shapes is calculated based on the modelled rolling element loads and a Fourier series based compliance approximation. The resulting model is computational low cost and provides an accurate description of the rolling element loads for flexible outer raceway structures. The latter is validated by a simulation-based comparison study with a well-established bearing simulation software tool. An experimental study finally shows the potential of the proposed model in a bearing load monitoring approach.
Systematic review: plantar fasciitis and prolonged weight bearing.
Waclawski, E R; Beach, J; Milne, A; Yacyshyn, E; Dryden, D M
2015-03-01
Plantar fasciitis (PF) is one of the most common causes of foot pain. Work can involve factors that may predispose to foot pain. To systematically review the evidence of the association between weight bearing (walking or standing) and PF among workers. Literature search of relevant indexing databases from inception to May 2012, grey literature, websites of relevant organizations and reference lists for all identified articles. Two reviewers independently selected studies for full review, assessed methodological quality and graded evidence. Findings were summarized qualitatively. Four studies were included; all were assessed as high or unclear risk of bias. Three studies were case-control studies; two used clinic populations and one used volunteers. The other study was cross-sectional involving the workforce of an assembly plant. A number of associations between PF and risk factors were identified including sex, obesity, foot biomechanics and job factors (e.g. job tenure). Two case-control studies and the cross-sectional study found an association with weight bearing, but the assessment of weight bearing varied (e.g. time on feet, time walking or standing). There was low-quality evidence to confirm a causal relationship (Royal College of General Practitioners (RCGP) * grade). This systematic review found low-quality evidence of an association between PF and weight-bearing tasks such as walking and standing on hard surfaces. The only occupations specifically identified as having higher risk were those associated with the engine assembly plant. Further research is required to fully determine the association between weight bearing and PF. © The Author 2015. Published by Oxford University Press on behalf of the Society of Occupational Medicine. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Finite element simulation of a novel composite light-weight microporous cladding panel
NASA Astrophysics Data System (ADS)
Tian, Lida; Wang, Dongyan
2018-04-01
A novel composite light-weight microporous cladding panel with matched connection detailing is developed. Numerical simulation on the experiment is conducted by ABAQUS. The accuracy and rationality of the finite element model is verified by comparison between the simulation and the experiment results. It is also indicated that the novel composite cladding panel is of desirable bearing capacity, stiffness and deformability under out-of-plane load.
Wünschel, Markus; Wülker, Nikolaus; Müller, Otto
2013-11-01
Females have a higher risk in terms of anterior cruciate ligament injuries during sports than males. Reasons for this fact may be different anatomy and muscle recruitment patterns leading to less protection for the cruciate- and collateral-ligaments. This in vitro study aims to evaluate gender differences in knee joint kinematics and muscle force during weight-bearing knee flexions. Thirty-four human knee specimens (17 females/17 males) were mounted on a dynamic knee simulator. Weight-bearing single-leg knee flexions were performed with different amounts of simulated body weight (BW). Gender-specific kinematics was measured with an ultrasonic motion capture system and different loading conditions were examined. Knee joint kinematics did not show significant differences regarding anteroposterior and medial-lateral movement as well as tibial varus-valgus and internal-external rotation. This applied to all simulated amounts of BW. Simulating 100 N BW in contrast to AF50 led to a significant higher quadriceps overall force in female knees from 45° to 85° of flexion in contrast to BW 50 N. In these female specimens, the quadriceps overall force was about 20 % higher than in male knees being constant in higher flexion angles. It is indicated by our results that in a squatting movement females compared with males produce higher muscle forces, suggesting an increased demand for muscular stabilization, whereas tibio-femoral kinematics was similar for both genders.
Menz, Hylton B.; Dufour, Alyssa B.; Katz, Patricia; Hannan, Marian T.
2015-01-01
Background The foot plays an important role in supporting the body when undertaking weight bearing activities. Aging is associated with an increased prevalence of foot pain and a lowering of the arch of the foot, both of which may impair mobility. Objective To examine the associations of foot pain, foot posture and dynamic foot function with self-reported mobility limitations in community-dwelling older adults. Methods Foot examinations were conducted on 1,860 members of the Framingham Study in 2002–2005. Foot posture was categorized as normal, planus or cavus using static pressure measurements, and foot function was categorized as normal, pronated or supinated using dynamic pressure measurements. Participants were asked whether they had foot pain and any difficulty performing a list of nine weight bearing tasks. Multivariate logistic regression and linear regression models were used to examine the associations of foot pain, posture, function and ability to perform these activities. Results After adjusting for age, sex, height and weight, foot pain was significantly associated with difficulty performing all nine weight bearing activities. Compared to those with normal foot posture and function, participants with planus foot posture were more likely to report difficulty remaining balanced (odds ratio [OR] = 1.40, 95% confidence interval [CI] 1.06 to 1.85; p=0.018) and individuals with pronated foot function were more likely to report difficulty walking across a small room (OR = 2.07, 95% CI 1.02 to 4.22; p=0.045). Foot pain and planus foot posture were associated with an overall mobility limitation score combining performances on each measure. Conclusion Foot pain, planus foot posture and pronated foot function are associated with self-reported difficulty undertaking common weight bearing tasks. Interventions to reduce foot pain and improve foot posture and function may therefore have a role in improving mobility in older adults. PMID:26645379
Sung, Yun-Hee; Kim, Chang-Ju; Yu, Byong-Kyu; Kim, Kyeong-Mi
2013-01-01
We investigated whether a hippotherapy simulator has influence on symmetric body weight bearing during gait in patients with stroke. Stroke patients were divided into a control group (n = 10) that received conventional rehabilitation for 60 min/day, 5 times/week for 4 weeks and an experimental group (n = 10) that used a hippotherapy simulator for 15 min/day, 5 times/week for 4 weeks after conventional rehabilitation for 45 min/day. Temporospatial gait assessed using OptoGait and trunk muscles (abdominis and erector spinae on affected side) activity evaluated using surface electromyography during sit-to-stand and gait. Prior to starting the experiment, pre-testing was performed. At the end of the 4-week intervention, we performed post-testing. Activation of the erector spinae in the experimental group was significantly increased compared to that in the control group (p < 0.01), whereas activation of the rectus abdominis decreased during sit-to-stand. Of the gait parameters, load response, single support, total double support, and pre-swing showed significant changes in the experimental group with a hippotherapy simulator compared to control group (p < 0.05). Moreover, activation of the erector spinae and rectus abdominis in gait correlate with changes of gait parameters including load response, single support, total double support, and pre-swing in experimental group. These findings suggest that use of a hippotherapy simulator to patients with stroke can improve asymmetric weight bearing by influencing trunk muscles.
NASA Technical Reports Server (NTRS)
Chung, W. Richard; Jara, Steve; Suffel, Susan
2003-01-01
To many national park campers and mountain climbers saving their foods in a safe and unbreakable storage container without worrying being attacked by a bear is a challenging task. In some parks, the park rangers have mandated that park visitors rent a bear canister for their food storage. Commercially available bear canisters are made of ABS plastic, weigh 2.8 pounds, and have a 180 cubic inch capacity for food storage. A new design with similar capacity was conducted in this study to reduce its weight and make it a stiffer and stronger canister. Two prototypes incorporating carbon prepreg with and without honeycomb constructions were manufactured using hand lay-up and vacuum bag forming techniques. A 6061-T6-aluminum ring was machined to dimensions in order to reinforce the opening area of the canister. Physical properties (weight and volume) along with mechanical properties (flexural strength and specific allowable moment) of the newly fabricated canisters are compared against the commercial ones. The composite canister weighs only 56% of the ABS one can withstand 9 times of the force greater. The advantages and limitations of using composite bear canisters will be discussed in the presentation.
Duvall, Susanne W.; Erickson, Sarah J.; MacLean, Peggy; Lowe, Jean R.
2014-01-01
The goal was to identify perinatal predictors of early executive dysfunction in preschoolers born very low birth weight. Fifty-seven preschoolers completed three executive function tasks (Dimensional Change Card Sort-Separated (inhibition, working memory and cognitive flexibility), Bear Dragon (inhibition and working memory) and Gift Delay Open (inhibition)). Relationships between executive function and perinatal medical severity factors (gestational age, days on ventilation, size for gestational age, maternal steroids and number of surgeries), and chronological age were investigated by multiple linear regression and logistic regression. Different perinatal medical severity factors were predictive of executive function tasks, with gestational age predicting Bear Dragon and Gift Open; and number of surgeries and maternal steroids predicting performance on Dimensional Change Card Sort-Separated. By understanding the relationship between perinatal medical severity factors and preschool executive outcomes, we may be able to identify children at highest risk for future executive dysfunction, thereby focusing targeted early intervention services. PMID:25117418
A better sequence-read simulator program for metagenomics.
Johnson, Stephen; Trost, Brett; Long, Jeffrey R; Pittet, Vanessa; Kusalik, Anthony
2014-01-01
There are many programs available for generating simulated whole-genome shotgun sequence reads. The data generated by many of these programs follow predefined models, which limits their use to the authors' original intentions. For example, many models assume that read lengths follow a uniform or normal distribution. Other programs generate models from actual sequencing data, but are limited to reads from single-genome studies. To our knowledge, there are no programs that allow a user to generate simulated data following non-parametric read-length distributions and quality profiles based on empirically-derived information from metagenomics sequencing data. We present BEAR (Better Emulation for Artificial Reads), a program that uses a machine-learning approach to generate reads with lengths and quality values that closely match empirically-derived distributions. BEAR can emulate reads from various sequencing platforms, including Illumina, 454, and Ion Torrent. BEAR requires minimal user input, as it automatically determines appropriate parameter settings from user-supplied data. BEAR also uses a unique method for deriving run-specific error rates, and extracts useful statistics from the metagenomic data itself, such as quality-error models. Many existing simulators are specific to a particular sequencing technology; however, BEAR is not restricted in this way. Because of its flexibility, BEAR is particularly useful for emulating the behaviour of technologies like Ion Torrent, for which no dedicated sequencing simulators are currently available. BEAR is also the first metagenomic sequencing simulator program that automates the process of generating abundances, which can be an arduous task. BEAR is useful for evaluating data processing tools in genomics. It has many advantages over existing comparable software, such as generating more realistic reads and being independent of sequencing technology, and has features particularly useful for metagenomics work.
Concept verification of three dimensional free motion simulator for space robot
NASA Technical Reports Server (NTRS)
Okamoto, Osamu; Nakaya, Teruomi; Pokines, Brett
1994-01-01
In the development of automatic assembling technologies for space structures, it is an indispensable matter to investigate and simulate the movements of robot satellites concerned with mission operation. The movement investigation and simulation on the ground will be effectively realized by a free motion simulator. Various types of ground systems for simulating free motion have been proposed and utilized. Some of these methods are a neutral buoyancy system, an air or magnetic suspension system, a passive suspension balance system, and a free flying aircraft or drop tower system. In addition, systems can be simulated by computers using an analytical model. Each free motion simulation method has limitations and well known problems, specifically, disturbance by water viscosity, limited number of degrees-of-freedom, complex dynamics induced by the attachment of the simulation system, short experiment time, and the lack of high speed super-computer simulation systems, respectively. The basic idea presented here is to realize 3-dimensional free motion. This is achieved by combining a spherical air bearing, a cylindrical air bearing, and a flat air bearing. A conventional air bearing system has difficulty realizing free vertical motion suspension. The idea of free vertical suspension is that a cylindrical air bearing and counter balance weight realize vertical free motion. This paper presents a design concept, configuration, and basic performance characteristics of an innovative free motion simulator. A prototype simulator verifies the feasibility of 3-dimensional free motion simulation.
Forces associated with launch into space do not impact bone fracture healing
NASA Astrophysics Data System (ADS)
Childress, Paul; Brinker, Alexander; Gong, Cynthia-May S.; Harris, Jonathan; Olivos, David J.; Rytlewski, Jeffrey D.; Scofield, David C.; Choi, Sungshin Y.; Shirazi-Fard, Yasaman; McKinley, Todd O.; Chu, Tien-Min G.; Conley, Carolynn L.; Chakraborty, Nabarun; Hammamieh, Rasha; Kacena, Melissa A.
2018-02-01
Segmental bone defects (SBDs) secondary to trauma invariably result in a prolonged recovery with an extended period of limited weight bearing on the affected limb. Soldiers sustaining blast injuries and civilians sustaining high energy trauma typify such a clinical scenario. These patients frequently sustain composite injuries with SBDs in concert with extensive soft tissue damage. For soft tissue injury resolution and skeletal reconstruction a patient may experience limited weight bearing for upwards of 6 months. Many small animal investigations have evaluated interventions for SBDs. While providing foundational information regarding the treatment of bone defects, these models do not simulate limited weight bearing conditions after injury. For example, mice ambulate immediately following anesthetic recovery, and in most cases are normally ambulating within 1-3 days post-surgery. Thus, investigations that combine disuse with bone healing may better test novel bone healing strategies. To remove weight bearing, we have designed a SBD rodent healing study in microgravity (μG) on the International Space Station (ISS) for the Rodent Research-4 (RR-4) Mission, which launched February 19, 2017 on SpaceX CRS-10 (Commercial Resupply Services). In preparation for this mission, we conducted an end-to-end mission simulation consisting of surgical infliction of SBD followed by launch simulation and hindlimb unloading (HLU) studies. In brief, a 2 mm defect was created in the femur of 10 week-old C57BL6/J male mice (n = 9-10/group). Three days after surgery, 6 groups of mice were treated as follows: 1) Vivarium Control (maintained continuously in standard cages); 2) Launch Negative Control (placed in the same spaceflight-like hardware as the Launch Positive Control group but were not subjected to launch simulation conditions); 3) Launch Positive Control (placed in spaceflight-like hardware and also subjected to vibration followed by centrifugation); 4) Launch Positive Experimental (identical to Launch Positive Control group, but placed in qualified spaceflight hardware); 5) Hindlimb Unloaded (HLU, were subjected to HLU immediately after launch simulation tests to simulate unloading in spaceflight); and 6) HLU Control (single housed in identical HLU cages but not suspended). Mice were euthanized 28 days after launch simulation and bone healing was examined via micro-Computed Tomography (μCT). These studies demonstrated that the mice post-surgery can tolerate launch conditions. Additionally, forces and vibrations associated with launch did not impact bone healing (p = .3). However, HLU resulted in a 52.5% reduction in total callus volume compared to HLU Controls (p = .0003). Taken together, these findings suggest that mice having a femoral SBD surgery tolerated the vibration and hypergravity associated with launch, and that launch simulation itself did not impact bone healing, but that the prolonged lack of weight bearing associated with HLU did impair bone healing. Based on these findings, we proceeded with testing the efficacy of FDA approved and novel SBD therapies using the unique spaceflight environment as a novel unloading model on SpaceX CRS-10.
Failure Simulation Testing of the Z-1 Spacesuit Titanium Bearing Assemblies
NASA Technical Reports Server (NTRS)
de Baca, Richard C.; Juarez, Alfredo; Peralta, Stephen; Tylka, Jonathan; Rhodes, Richard
2016-01-01
The Z-2 is a candidate for NASA's next generation spacesuit, designed for a range of possible missions with enhanced mobility for spacewalks both on planetary surfaces and in microgravity. Increased mobility was accomplished through innovations in shoulder and hip joints, using a number of new bearings to allow spacesuit wearers to dip, walk, and bend with ease; all important tasks for a planetary explorer collecting samples or traveling over rough terrain. The Advanced Spacesuit Development Team of NASA Johnson Space Center requested that the NASA White Sands Test Facility (WSTF) perform a series failure simulation tests on three titanium bearing assemblies, an elemental part of the joint construction used in new spacesuit designs. This testing simulated two undetected failures within the bearings and as a result the objective of this test program was to evaluate whether a failed or failing bearing could result in ignition of the titanium race material due to friction. The first failure was an inner seal leak sufficient to pressurize the race with +99 percent oxygen. The second failure was an improperly installed or mismatched ball port that created a protrusion in the ball bearing race, partially obstructing the nominal rolling path of each ball bearing. When the spacesuit bearings are assembled, bearing balls are loaded into the assembly via a ball port. The ball port is specific and unique to each bearing assembly (matched pair). The simulated mismatched ball port is a significant source of friction, which would be caused by an assembly error. To evaluate this risk, the bearings were cycled in a simulated worst-case scenario environment, with operational loads, and potential flaw conditions. During test the amount of actuation torque required and heat generated through continuous operation were measured and the bearings were observed for sparks or burning events. This paper provides detailed descriptions of the test hardware, methodology, and results.
Schmitz, Randy J; Kim, Hyunsoo; Shultz, Sandra J
2015-01-01
Fatigue is suggested to be a risk factor for anterior cruciate ligament injury. Fatiguing exercise can affect neuromuscular control and laxity of the knee joint, which may render the knee less able to resist externally applied loads. Few authors have examined the effects of fatiguing exercise on knee biomechanics during the in vivo transition of the knee from non-weight bearing to weight bearing, the time when anterior cruciate ligament injury likely occurs. To investigate the effect of fatiguing exercise on tibiofemoral joint biomechanics during the transition from non-weight bearing to early weight bearing. Cross-sectional study. Research laboratory. Ten participants (5 men and 5 women; age = 25.3 ± 4.0 years) with no previous history of knee-ligament injury to the dominant leg. Participants were tested before (preexercise) and after (postexercise) a protocol consisting of repeated leg presses (15 repetitions from 10°-40° of knee flexion, 10 seconds' rest) against a 60% body-weight load until they were unable to complete a full bout of repetitions. Electromagnetic sensors measured anterior tibial translation and knee-flexion excursion during the application of a 40% body-weight axial compressive load to the bottom of the foot, simulating weight acceptance. A force transducer recorded axial compressive force. The axial compressive force (351.8 ± 44.3 N versus 374.0 ± 47.9 N; P = .018), knee-flexion excursion (8.0° ± 4.0° versus 10.2° ± 3.7°; P = .046), and anterior tibial translation (6.7 ± 1.7 mm versus 8.2 ± 1.9 mm; P < .001) increased from preexercise to postexercise. No significant correlations were noted. Neuromuscular fatigue may impair initial knee-joint stabilization during weight acceptance, leading to greater accessory motion at the knee and the potential for greater anterior cruciate ligament loading.
Influence of bi- and tri-compartmental knee arthroplasty on the kinematics of the knee joint.
Wünschel, Markus; Lo, Jiahsuan; Dilger, Torsten; Wülker, Nikolaus; Müller, Otto
2011-01-27
The cruciate ligaments are important stabilizers of the knee joint and determine joint kinematics in the natural knee and after cruciate retaining arthroplasty.No in vitro data is available to biomechanically evaluate the ability of the anterior cruciate ligament (ACL) to maintain knee joint kinematics after bicruciate-retaining bi-compartmental knee arthroplasty (BKA).Therefore, the objective of the current study was to investigate the kinematics of the natural knee joint, before and after installing bicruciate-retaining BKA and posterior cruciate retaining total knee arthroplasty. Specifically, we incorporated a dynamic knee simulator to simulate weight-bearing flexions on cadaveric knee specimen before and after surgical manipulations. In this cadaveric study we investigated rotational and translational tibiofemoral kinematics during simulated weight-bearing flexions of the intact knee, after bi-compartmental knee arthroplasty (BKA+), after resecting the ACL in BKA (BKA-), and after posterior cruciate retaining total knee arthroplasty (TKA). Rotation of BKA+ is closest to the intact knee joint, whereas TKA shows significant differences from 30 to 90 degree of flexion. Within the tested flexion range (15 to 90 degree of flexion), there was no significant difference in the anterior-posterior translation among intact, BKA+, and TKA knees. Resecting the ACL in BKA leads to a significant anterior tibial translation. BKA with intact cruciate ligaments resembles rotation and translation of the natural knee during a simulated weight-bearing flexion. It is a suitable treatment option for medial and patellofemoral osteoarthritis with advantages in rotational characteristics compared to TKA.
Fatigue strength of common tibial intramedullary nail distal locking screws
Griffin, Lanny V; Harris, Robert M; Zubak, Joseph J
2009-01-01
Background Premature failure of either the nail and/or locking screws with unstable fracture patterns may lead to angulation, shortening, malunion, and IM nail migration. Up to thirty percent of all unreamed nail locking screws can break after initial weight bearing is allowed at 8–10 weeks if union has not occurred. The primary problem this presents is hardware removal during revision surgery. The purposes of our study was to evaluate the relative fatigue resistance of distal locking screws and bolts from representative manufacturers of tibial IM nail systems, and develop a relative risk assessment of screws and materials used. Evaluations included quantitative and qualitative measures of the relative performance of these screws. Methods Fatigue tests were conducted to simulate a comminuted fracture that was treated by IM nailing assuming that all load was carried by the screws. Each screw type was tested ten times in a single screw configuration. One screw type was tested an additional ten times in a two-screw parallel configuration. Fatigue tests were performed using a servohydraulic materials testing system and custom fixturing that simulated screws placed in the distal region of an appropriately sized tibial IM nail. Fatigue loads were estimated based on a seventy-five kilogram individual at full weight bearing. The test duration was one million cycles (roughly one year), or screw fracture, whichever occurred first. Failure analysis of a representative sample of titanium alloy and stainless steel screws included scanning electron microscopy (SEM) and quantitative metallography. Results The average fatigue life of a single screw with a diameter of 4.0 mm was 1200 cycles, which would correspond roughly to half a day of full weight bearing. Single screws with a diameter of 4.5 mm or larger have approximately a 50 percent probability of withstanding a week of weight bearing, whereas a single 5.0 mm diameter screw has greater than 90 percent probability of withstanding more than a week of weight bearing. If two small diameter screws are used, our tests showed that the probability of withstanding a week of weight bearing increases from zero to about 20 percent, which is similar to having a single 4.5 mm diameter screw providing fixation. Conclusion Our results show that selecting the system that uses the largest distal locking screws would offer the best fatigue resistance for an unstable fracture pattern subjected to full weight bearing. Furthermore, using multiple screws will substantially reduce the risk of premature hardware failure. PMID:19371438
Intelligent Engine Systems: Bearing System
NASA Technical Reports Server (NTRS)
Singh, Arnant P.
2008-01-01
The overall requirements necessary for sensing bearing distress and the related criteria to select a particular rotating sensor were established during the phase I. The current phase II efforts performed studies to evaluate the Robustness and Durability Enhancement of the rotating sensors, and to design, and develop the Built-in Telemetry System concepts for an aircraft engine differential sump. A generic test vehicle that can test the proposed bearing diagnostic system was designed, developed, and built. The Timken Company, who also assisted with testing the GE concept of using rotating sensors for the differential bearing diagnostics during previous phase, was selected as a subcontractor to assist General Electric (GE) for the design, and procurement of the test vehicle. A purchase order was prepared to define the different sub-tasks, and deliverables for this task. The University of Akron was selected to provide the necessary support for installing, and integrating the test vehicle with their newly designed test facility capable of simulating the operating environment for the planned testing. The planned testing with good and damaged bearings will be on hold pending further continuation of this effort during next phase.
Forces associated with launch into space do not impact bone fracture healing.
Childress, Paul; Brinker, Alexander; Gong, Cynthia-May S; Harris, Jonathan; Olivos, David J; Rytlewski, Jeffrey D; Scofield, David C; Choi, Sungshin Y; Shirazi-Fard, Yasaman; McKinley, Todd O; Chu, Tien-Min G; Conley, Carolynn L; Chakraborty, Nabarun; Hammamieh, Rasha; Kacena, Melissa A
2018-02-01
Segmental bone defects (SBDs) secondary to trauma invariably result in a prolonged recovery with an extended period of limited weight bearing on the affected limb. Soldiers sustaining blast injuries and civilians sustaining high energy trauma typify such a clinical scenario. These patients frequently sustain composite injuries with SBDs in concert with extensive soft tissue damage. For soft tissue injury resolution and skeletal reconstruction a patient may experience limited weight bearing for upwards of 6 months. Many small animal investigations have evaluated interventions for SBDs. While providing foundational information regarding the treatment of bone defects, these models do not simulate limited weight bearing conditions after injury. For example, mice ambulate immediately following anesthetic recovery, and in most cases are normally ambulating within 1-3 days post-surgery. Thus, investigations that combine disuse with bone healing may better test novel bone healing strategies. To remove weight bearing, we have designed a SBD rodent healing study in microgravity (µG) on the International Space Station (ISS) for the Rodent Research-4 (RR-4) Mission, which launched February 19, 2017 on SpaceX CRS-10 (Commercial Resupply Services). In preparation for this mission, we conducted an end-to-end mission simulation consisting of surgical infliction of SBD followed by launch simulation and hindlimb unloading (HLU) studies. In brief, a 2 mm defect was created in the femur of 10 week-old C57BL6/J male mice (n = 9-10/group). Three days after surgery, 6 groups of mice were treated as follows: 1) Vivarium Control (maintained continuously in standard cages); 2) Launch Negative Control (placed in the same spaceflight-like hardware as the Launch Positive Control group but were not subjected to launch simulation conditions); 3) Launch Positive Control (placed in spaceflight-like hardware and also subjected to vibration followed by centrifugation); 4) Launch Positive Experimental (identical to Launch Positive Control group, but placed in qualified spaceflight hardware); 5) Hindlimb Unloaded (HLU, were subjected to HLU immediately after launch simulation tests to simulate unloading in spaceflight); and 6) HLU Control (single housed in identical HLU cages but not suspended). Mice were euthanized 28 days after launch simulation and bone healing was examined via micro-Computed Tomography (µCT). These studies demonstrated that the mice post-surgery can tolerate launch conditions. Additionally, forces and vibrations associated with launch did not impact bone healing (p = .3). However, HLU resulted in a 52.5% reduction in total callus volume compared to HLU Controls (p = .0003). Taken together, these findings suggest that mice having a femoral SBD surgery tolerated the vibration and hypergravity associated with launch, and that launch simulation itself did not impact bone healing, but that the prolonged lack of weight bearing associated with HLU did impair bone healing. Based on these findings, we proceeded with testing the efficacy of FDA approved and novel SBD therapies using the unique spaceflight environment as a novel unloading model on SpaceX CRS-10. Copyright © 2017 The Committee on Space Research (COSPAR). All rights reserved.
2010-08-01
using load - bearing tanks with parasitic TPS was considered to be a lower weight design when all details were accounted for. The cold structure...share one very key element with the design of load bearing hot structure – the design drive toward thin gauge metallic skin under complex and coupled...39 skin panel joints and their susceptibility to high acoustic loading coupled with transient heating, and hot structure skin deflections and
Influence of bi- and tri-compartmental knee arthroplasty on the kinematics of the knee joint
2011-01-01
Background The cruciate ligaments are important stabilizers of the knee joint and determine joint kinematics in the natural knee and after cruciate retaining arthroplasty. No in vitro data is available to biomechanically evaluate the ability of the anterior cruciate ligament (ACL) to maintain knee joint kinematics after bicruciate-retaining bi-compartmental knee arthroplasty (BKA). Therefore, the objective of the current study was to investigate the kinematics of the natural knee joint, before and after installing bicruciate-retaining BKA and posterior cruciate retaining total knee arthroplasty. Specifically, we incorporated a dynamic knee simulator to simulate weight-bearing flexions on cadaveric knee specimen before and after surgical manipulations. Methods In this cadaveric study we investigated rotational and translational tibiofemoral kinematics during simulated weight-bearing flexions of the intact knee, after bi-compartmental knee arthroplasty (BKA+), after resecting the ACL in BKA (BKA-), and after posterior cruciate retaining total knee arthroplasty (TKA). Results Rotation of BKA+ is closest to the intact knee joint, whereas TKA shows significant differences from 30 to 90 degree of flexion. Within the tested flexion range (15 to 90 degree of flexion), there was no significant difference in the anterior-posterior translation among intact, BKA+, and TKA knees. Resecting the ACL in BKA leads to a significant anterior tibial translation. Conclusions BKA with intact cruciate ligaments resembles rotation and translation of the natural knee during a simulated weight-bearing flexion. It is a suitable treatment option for medial and patellofemoral osteoarthritis with advantages in rotational characteristics compared to TKA. PMID:21272328
Altered cellular kinetics in growth plate according to alterations in weight bearing.
Park, Hoon; Kong, Sun Young; Kim, Hyun Woo; Yang, Ick Hwan
2012-05-01
To examine the effects of change in weight bearing on the growth plate metabolism, a simulated animal model of weightlessness was introduced and the chondrocytes' cellular kinetics was evaluated. Unloading condition on the hind-limb of Sprague-Dawley rats was created by fixing a tail and lifting the hind-limb. Six rats aged 6 weeks old were assigned to each group of unloading, reloading, and control groups of unloading or reloading. Unloading was maintained for three weeks, and then reloading was applied for another one week thereafter. Histomorphometry for the assessment of vertical length of the growth plate, 5-bromo-2'-deoxyuridin immunohistochemistry for cellular kinetics, and biotin nick end labeling transferase-mediated deoxyuridine triphosphate-biotin nick end labeling (TUNEL) assay for chondrocytes apoptosis in the growth plate were performed. The vertical length of the growth plate and the proliferative potential of chondrocytes were decreased in the unloading group compared to those of control groups. Inter-group differences were more significant in the proliferative and hypertrophic zones. Reloading increased the length of growth plate and proliferative potential of chondrocytes. However, apoptotic changes in the growth plate were not affected by the alterations of weight bearing. Alterations in the weight bearing induced changes in the chondrocytic proliferative potential of the growth plate, however, had no effects on the apoptosis. This may explain why non-weight bearing in various clinical situations hampers normal longitudinal bone growth. Further studies on the factors for reversibility of chondrocytic proliferation upon variable mechanical stresses are needed.
Evaluation of changes in pelvic belt tension during 2 weight-bearing functional tasks.
Arumugam, Ashokan; Milosavljevic, Stephan; Woodley, Stephanie; Sole, Gisela
2012-06-01
The purposes of this study were to evaluate changes in pelvic belt tension during 2 weight-bearing functional tasks (transition from bipedal to unipedal stance [BUS] and walking) and to evaluate the reliability and the percentage variation for belt tension scores from trial to trial. A cross-sectional repeated-measures study was conducted with 10 healthy male participants (mean age, 28.3 ± 8.8years). Participants performed 10 trials of BUS and walking while wearing a nonelastic pelvic compression belt (PCB) applied distal to the anterior superior iliac spines, with a load cell positioned in the center of the belt. The load cell was calibrated using known weights (1-10kg) to define the relationship between the applied tension and voltage change (R(2) = 0.99). Load cell tension values were recorded in voltage signals and then converted to newtons of force using appropriate conversion values (0.012V = 10N). Mean and standard deviation values, intraclass correlation coefficients (ICC 3,1), and percentage standard error of measurements (% SEM) were analyzed for PCB tension recorded during the BUS and walking trials. The mean tension achieved with a PCB was found to be 41.02 (±4.23) N during BUS and 44.07 (±5.80) N during walking. The trial-to-trial reliability (ICC 3,1) was high (ICC ≥0.9), and the variation in PCB tension across 10 trials (% SEM) was 4% or less. The mean tension achieved during the tasks was 44 N or less. The reliability is high, and the variation is low across the trials, which implies that a PCB could be used to produce consistent effects during repetition of the tasks (BUS and walking). Copyright © 2012 National University of Health Sciences. Published by Mosby, Inc. All rights reserved.
The Avoidance of Saturation Limits in Magnetic Bearing Systems During Transient Excitation
NASA Technical Reports Server (NTRS)
Rutland, Neil K.; Keogh, Patrick S.; Burrows, Clifford R.
1996-01-01
When a transient event, such as mass loss, occurs in a rotor/magnetic bearing system, optimal vibration control forces may exceed bearing capabilities. This will be inevitable when the mass loss is sufficiently large and a conditionally unstable dynamic system could result if the bearing characteristic become non-linear. This paper provides a controller design procedure to suppress, where possible, bearing force demands below saturation levels while maintaining vibration control. It utilizes H(sub infinity) optimization with appropriate input and output weightings. Simulation of transient behavior following mass loss from a flexible rotor is used to demonstrate the avoidance of conditional instability. A compromise between transient control force and vibration levels was achieved.
Dill, Karli E; Begalle, Rebecca L; Frank, Barnett S; Zinder, Steven M; Padua, Darin A
2014-01-01
Ankle-dorsiflexion (DF) range of motion (ROM) may influence movement variables that are known to affect anterior cruciate ligament loading, such as knee valgus and knee flexion. To our knowledge, researchers have not studied individuals with limited or normal ankle DF-ROM to investigate the relationship between those factors and the lower extremity movement patterns associated with anterior cruciate ligament injury. To determine, using 2 different measurement techniques, whether knee- and ankle-joint kinematics differ between participants with limited and normal ankle DF-ROM. Cross-sectional study. Sports medicine research laboratory. Forty physically active adults (20 with limited ankle DF-ROM, 20 with normal ankle DF-ROM). Ankle DF-ROM was assessed using 2 techniques: (1) nonweight-bearing ankle DF-ROM with the knee straight, and (2) weight-bearing lunge (WBL). Knee flexion, knee valgus-varus, knee internal-external rotation, and ankle DF displacements were assessed during the overhead-squat, single-legged squat, and jump-landing tasks. Separate 1-way analyses of variance were performed to determine whether differences in knee- and ankle-joint kinematics existed between the normal and limited groups for each assessment. We observed no differences between the normal and limited groups when classifying groups based on nonweight-bearing passive-ankle DF-ROM. However, individuals with greater ankle DF-ROM during the WBL displayed greater knee-flexion and ankle-DF displacement and peak knee flexion during the overhead-squat and single-legged squat tasks. In addition, those individuals also demonstrated greater knee-varus displacement during the single-legged squat. Greater ankle DF-ROM assessed during the WBL was associated with greater knee-flexion and ankle-DF displacement during both squatting tasks as well as greater knee-varus displacement during the single-legged squat. Assessment of ankle DF-ROM using the WBL provided important insight into compensatory movement patterns during squatting, whereas nonweight-bearing passive ankle DF-ROM did not. Improving ankle DF-ROM during the WBL may be an important intervention for altering high-risk movement patterns commonly associated with noncontact anterior cruciate ligament injury.
Effect of simulated weightlessness on the immune system in rats
NASA Technical Reports Server (NTRS)
Caren, L. D.; Mandel, A. D.; Nunes, J. A.
1980-01-01
Rats suspended in a model system designed to simulate many aspects of weightlessness were immunized with sheep red blood cells. Parameters measured on these and control rats included titers of anti-sheep red blood cell antibodies, serum immunoglobulin levels, spleen and thymus weights, hematocrits, and leukocyte differential counts on peripheral blood. No significant differences were found between test and weight-bearing, harnessed controls; however, the thymuses of animals in both these groups were significantly smaller than untreated cage controls. The lack of an effect of simulated weightlessness on the immune system is an interesting result, and its significance is discussed.
Raaben, Marco; Holtslag, Herman R; Leenen, Luke P H; Augustine, Robin; Blokhuis, Taco J
2018-01-01
Individuals with lower extremity fractures are often instructed on how much weight to bear on the affected extremity. Previous studies have shown limited therapy compliance in weight bearing during rehabilitation. In this study we investigated the effect of real-time visual biofeedback on weight bearing in individuals with lower extremity fractures in two conditions: full weight bearing and touch-down weight bearing. 11 participants with full weight bearing and 12 participants with touch-down weight bearing after lower extremity fractures have been measured with an ambulatory biofeedback system. The participants first walked 15m and the biofeedback system was only used to register the weight bearing. The same protocol was then repeated with real-time visual feedback during weight bearing. The participants could thereby adapt their loading to the desired level and improve therapy compliance. In participants with full weight bearing, real-time visual biofeedback resulted in a significant increase in loading from 50.9±7.51% bodyweight (BW) without feedback to 63.2±6.74%BW with feedback (P=0.0016). In participants with touch-down weight bearing, the exerted lower extremity load decreased from 16.7±9.77kg without feedback to 10.27±4.56kg with feedback (P=0.0718). More important, the variance between individual steps significantly decreased after feedback (P=0.018). Ambulatory monitoring weight bearing after lower extremity fractures showed that therapy compliance is low, both in full and touch-down weight bearing. Real-time visual biofeedback resulted in significantly higher peak loads in full weight bearing and increased accuracy of individual steps in touch-down weight bearing. Real-time visual biofeedback therefore results in improved therapy compliance after lower extremity fractures. Copyright © 2017 Elsevier B.V. All rights reserved.
Human Performance in Continuous Operations. Volume 3. Technical Documentation
1980-03-01
completed for the U. S. Commander, V Corps. Artillery, by Manning (1978). Manning collected information which bears on the following three questions: 0 Can...performance data were not collected in these pre- liminary studies. Field Studies of Continuous Tank OperationsLI __ _ _ __ _ _ _ To simulate a combat...on routine, monotonous tasks tends A show rapid and severe decrement after peri- odk of more than 24 hours without sleep. I Increasing task complexity
Carrera, Ion; Gelber, Pablo Eduardo; Chary, Gaetan; González-Ballester, Miguel A; Monllau, Juan Carlos; Noailly, Jerome
2016-10-01
To assess, with finite element (FE) calculations, whether immediate weight bearing would be possible after surgical stabilization either with cannulated screws or with a locking plate in a split fracture of the lateral tibial plateau (LTP). A split fracture of the LTP was recreated in a FE model of a human tibia. A three-dimensional FE model geometry of a human femur-tibia system was obtained from the VAKHUM project database, and was built from CT images from a subject with normal bone morphologies and normal alignment. The mesh of the tibia was reconverted into a geometry of NURBS surfaces. A split fracture of the lateral tibial plateau was reproduced by using geometrical data from patient radiographs. A locking screw plate (LP) and a cannulated screw (CS) systems were modelled to virtually reduce the fracture and 80 kg static body-weight was simulated. While the simulated body-weight led to clinically acceptable interfragmentary motion, possible traumatic bone shear stresses were predicted nearby the cannulated screws. With a maximum estimation of about 1.7 MPa maximum bone shear stresses, the Polyax system might ensure more reasonable safety margins. Split fractures of the LTP fixed either with locking screw plate or cannulated screws showed no clinically relevant IFM in a FE model. The locking screw plate showed higher mechanical stability than cannulated screw fixation. The locking screw plate might also allow full or at least partial weight bearing under static posture at time zero.
Analytic Modeling of the Hydrodynamic, Thermal, and Structural Behavior of Foil Thrust Bearings
NASA Technical Reports Server (NTRS)
Bruckner, Robert J.; DellaCorte, Christopher; Prahl, Joseph M.
2005-01-01
A simulation and modeling effort is conducted on gas foil thrust bearings. A foil bearing is a self acting hydrodynamic device capable of separating stationary and rotating components of rotating machinery by a film of air or other gaseous lubricant. Although simple in appearance these bearings have proven to be complicated devices in analysis. They are sensitive to fluid structure interaction, use a compressible gas as a lubricant, may not be in the fully continuum range of fluid mechanics, and operate in the range where viscous heat generation is significant. These factors provide a challenge to the simulation and modeling task. The Reynolds equation with the addition of Knudsen number effects due to thin film thicknesses is used to simulate the hydrodynamics. The energy equation is manipulated to simulate the temperature field of the lubricant film and combined with the ideal gas relationship, provides density field input to the Reynolds equation. Heat transfer between the lubricant and the surroundings is also modeled. The structural deformations of the bearing are modeled with a single partial differential equation. The equation models the top foil as a thin, bending dominated membrane whose deflections are governed by the biharmonic equation. A linear superposition of hydrodynamic load and compliant foundation reaction is included. The stiffness of the compliant foundation is modeled as a distributed stiffness that supports the top foil. The system of governing equations is solved numerically by a computer program written in the Mathematica computing environment. Representative calculations and comparisons with experimental results are included for a generation I gas foil thrust bearing.
Occupational-Specific Strength Predicts Astronaut-Related Task Performance in a Weighted Suit.
Taylor, Andrew; Kotarsky, Christopher J; Bond, Colin W; Hackney, Kyle J
2018-01-01
Future space missions beyond low Earth orbit will require deconditioned astronauts to perform occupationally relevant tasks within a planetary spacesuit. The prediction of time-to-completion (TTC) of astronaut tasks will be critical for crew safety, autonomous operations, and mission success. This exploratory study determined if the addition of task-specific strength testing to current standard lower body testing would enhance the prediction of TTC in a 1-G test battery. Eight healthy participants completed NASA lower body strength tests, occupationally specific strength tests, and performed six task simulations (hand drilling, construction wrenching, incline walking, collecting weighted samples, and dragging an unresponsive crewmember to safety) in a 48-kg weighted suit. The TTC for each task was recorded and summed to obtain a total TTC for the test battery. Linear regression was used to predict total TTC with two models: 1) NASA lower body strength tests; and 2) NASA lower body strength tests + occupationally specific strength tests. Total TTC of the test battery ranged from 20.2-44.5 min. The lower body strength test alone accounted for 61% of the variability in total TTC. The addition of hand drilling and wrenching strength tests accounted for 99% of the variability in total TTC. Adding occupationally specific strength tests (hand drilling and wrenching) to standard lower body strength tests successfully predicted total TTC in a performance test battery within a weighted suit. Future research should couple these strength tests with higher fidelity task simulations to determine the utility and efficacy of task performance prediction.Taylor A, Kotarsky CJ, Bond CW, Hackney KJ. Occupational-specific strength predicts astronaut-related task performance in a weighted suit. Aerosp Med Hum Perform. 2018; 89(1):58-62.
Eccentric exercise training as a countermeasure to non-weight-bearing soleus muscle atrophy
NASA Technical Reports Server (NTRS)
Kirby, Christopher R.; Ryan, Mirelle J.; Booth, Frank W.
1992-01-01
This investigation tested whether eccentric resistance training could prevent soleus muscle atrophy during non-weight bearing. Adult female rats were randomly assigned to either weight bearing +/- intramuscular electrodes or non-weight bearing +/- intramuscular electrodes groups. Electrically stimulated maximal eccentric contractions were performed on anesthetized animals at 48-h intervals during the 10-day experiment. Non-weight bearing significantly reduced soleus muscle wet weight (28-31 percent) and noncollagenous protein content (30-31 percent) compared with controls. Eccentric exercise training during non-weight bearing attenuated but did not prevent the loss of soleus muscle wet weight and noncollagenous protein by 77 and 44 percent, respectively. The potential of eccentric exercise training as an effective and highly efficient counter-measure to non-weight-bearing atrophy is demonstrated in the 44 percent attenuation of soleus muscle noncollagenous protein loss by eccentric exercise during only 0.035 percent of the total non-weight-bearing time period.
Interfacing modules for integrating discipline specific structural mechanics codes
NASA Technical Reports Server (NTRS)
Endres, Ned M.
1989-01-01
An outline of the organization and capabilities of the Engine Structures Computational Simulator (Simulator) at NASA Lewis Research Center is given. One of the goals of the research at Lewis is to integrate various discipline specific structural mechanics codes into a software system which can be brought to bear effectively on a wide range of engineering problems. This system must possess the qualities of being effective and efficient while still remaining user friendly. The simulator was initially designed for the finite element simulation of gas jet engine components. Currently, the simulator has been restricted to only the analysis of high pressure turbine blades and the accompanying rotor assembly, although the current installation can be expanded for other applications. The simulator presently assists the user throughout its procedures by performing information management tasks, executing external support tasks, organizing analysis modules and executing these modules in the user defined order while maintaining processing continuity.
Active magnetic damper in a power transmission system
NASA Astrophysics Data System (ADS)
Kozanecka, D.; Kozanecki, Z.; Łagodziński, J.
2011-05-01
In rotor dynamics, the bearing characteristics exerts a decisive influence on dynamics of the rotating shaft. The research and application experience have led to active magnetic bearings (AMBs), which allow for unique applications in rotating systems. The paper presents the investigations concerning optimization of the magnetic bearing construction. An active magnetic bearing operates as a radial, auxiliary damper, which cooperates with the long, flexible shaft line (aircraft industry applications) and modifies its dynamic properties. In the developed concept of AMBs for aviation purposes, a necessity of increasing its bearing load capacity and damping has occurred. The second important criterion is a weight reduction. This advanced problem leads to specific requirements on the design and materials for the AMB. To achieve these goals, some simulations have been performed. The experimental results are presented as well.
Optimizing Disaster Relief: Real-Time Operational and Tactical Decision Support
1993-01-01
efficiencies in completing the tAsks. Allocations recognize task priorities and the logistica l effects of geographic prox- imity, In addition...as if they ar~ collocated. Arcs connect loc-•I J>airs of zones to represent feasible dTrect point-to-point transportation and bear cost> ror...data to thl.’ de >~red level of aggregation. We have tested ARES manuall)’ ;mtl by replacins tbc deci~ion maker wrlh the decision simulator which
Rath, Ehud; Sharfman, Zachary T; Paret, Matan; Amar, Eyal; Drexler, Michael; Bonin, Nicolas
2017-01-01
The objectives of this study are to survey the weight-bearing limitation practices and delay for returning to running and impact sports of high volume hip arthroscopy orthopedic surgeons. The study was designed in the form of expert survey questionnaire. Evidence-based data are scares regarding hip arthroscopy post-operative weight-bearing protocols. An international cross-sectional anonymous Internet survey of 26 high-volume hip arthroscopy specialized surgeons was conducted to report their weight-bearing limitations and rehabilitation protocols after various arthroscopic hip procedures. The International Society of Hip Arthroscopy invited this study. The results were examined in the context of supporting literature to inform the studies suggestions. Four surgeons always allow immediate weight bearing and five never offer immediate weight bearing. Seventeen surgeons provide weight bearing depending on the procedures performed: 17 surgeons allowed immediate weight bearing after labral resection, 10 after labral repair and 8 after labral reconstruction. Sixteen surgeons allow immediate weight bearing after psoas tenotomy. Twenty-one respondents restrict weight bearing after microfracture procedures for 3-8 weeks post-operatively. Return to running and impact sports were shorter for labral procedures and bony procedures and longer for cartilaginous and capsular procedures. Marked variability exists in the post-operative weight-bearing practices of hip arthroscopy surgeons. This study suggests that most surgeons allow immediate weight bearing as tolerated after labral resection, acetabular osteoplasty, chondroplasty and psoas tenotomy. For cartilage defect procedures, 6 weeks or more non-weight bearing is suggested depending on the area of the defect and lateral central edge angle. Delayed return to sports activities is suggested after microfracture procedures. The level of evidence was Level V expert opinions.
Rath, Ehud; Paret, Matan; Amar, Eyal; Drexler, Michael; Bonin, Nicolas
2017-01-01
Abstract The objectives of this study are to survey the weight-bearing limitation practices and delay for returning to running and impact sports of high volume hip arthroscopy orthopedic surgeons. The study was designed in the form of expert survey questionnaire. Evidence-based data are scares regarding hip arthroscopy post-operative weight-bearing protocols. An international cross-sectional anonymous Internet survey of 26 high-volume hip arthroscopy specialized surgeons was conducted to report their weight-bearing limitations and rehabilitation protocols after various arthroscopic hip procedures. The International Society of Hip Arthroscopy invited this study. The results were examined in the context of supporting literature to inform the studies suggestions. Four surgeons always allow immediate weight bearing and five never offer immediate weight bearing. Seventeen surgeons provide weight bearing depending on the procedures performed: 17 surgeons allowed immediate weight bearing after labral resection, 10 after labral repair and 8 after labral reconstruction. Sixteen surgeons allow immediate weight bearing after psoas tenotomy. Twenty-one respondents restrict weight bearing after microfracture procedures for 3–8 weeks post-operatively. Return to running and impact sports were shorter for labral procedures and bony procedures and longer for cartilaginous and capsular procedures. Marked variability exists in the post-operative weight-bearing practices of hip arthroscopy surgeons. This study suggests that most surgeons allow immediate weight bearing as tolerated after labral resection, acetabular osteoplasty, chondroplasty and psoas tenotomy. For cartilage defect procedures, 6 weeks or more non-weight bearing is suggested depending on the area of the defect and lateral central edge angle. Delayed return to sports activities is suggested after microfracture procedures. The level of evidence was Level V expert opinions. PMID:28630722
Battaglia, Patrick J; Mattox, Ross; Winchester, Brett; Kettner, Norman W
The primary aim of this study was to determine the reliability of diagnostic ultrasound imaging for select intrinsic foot muscles using both non-weight-bearing and weight-bearing postures. Our secondary aim was to describe the change in muscle cross-sectional area (CSA) and dorsoplantar thickness when bearing weight. An ultrasound examination was performed with a linear ultrasound transducer operating between 9 and 12 MHz. Long-axis and short-axis ultrasound images of the abductor hallucis, flexor digitorum brevis, and quadratus plantae were obtained in both the non-weight-bearing and weight-bearing postures. Two examiners independently collected ultrasound images to allow for interexaminer and intraexaminer reliability calculation. The change in muscle CSA and dorsoplantar thickness when bearing weight was also studied. There were 26 participants (17 female) with a mean age of 25.5 ± 3.8 years and a mean body mass index of 28.0 ± 7.8 kg/m 2 . Inter-examiner reliability was excellent when measuring the muscles in short axis (intraclass correlation coefficient >0.75) and fair to good in long axis (intraclass correlation coefficient >0.4). Intraexaminer reliability was excellent for the abductor hallucis and flexor digitorum brevis and ranged from fair to good to excellent for the quadratus plantae. Bearing weight did not reduce interexaminer or intraexaminer reliability. All muscles exhibited a significant increase in CSA when bearing weight. This is the first report to describe weight-bearing diagnostic ultrasound of the intrinsic foot muscles. Ultrasound imaging is reliable when imaging these muscles bearing weight. Furthermore, muscle CSA increases in the weight-bearing posture. Copyright © 2016. Published by Elsevier Inc.
Heare, Austin; Kramer, Nicholas; Salib, Christopher; Mauffrey, Cyril
2017-07-01
Despite overall improved outcomes with open reduction and internal fixation of acetabular fractures, posterior wall fractures show disproportionately poor results. The effect of weight bearing on outcomes of fracture management has been investigated in many lower extremity fractures, but evidence-based recommendations in posterior wall acetabular fractures are lacking. The authors systematically reviewed the current literature to determine if a difference in outcome exists between early and late postoperative weight-bearing protocols for surgically managed posterior wall acetabular fractures. PubMed and MEDLINE were searched for posterior wall acetabular fracture studies that included weight-bearing protocols and Merle d'Aubigné functional scores. Twelve studies were identified. Each study was classified as either early or late weight bearing. Early weight bearing was defined as full, unrestricted weight bearing at or before 12 weeks postoperatively. Late weight bearing was defined as restricted weight bearing for greater than 12 weeks postoperatively. The 2 categories were then compared by functional score using a 2-tailed t test and by complication rate using chi-square analysis. Six studies (152 fractures) were placed in the early weight-bearing category. Six studies (302 fractures) were placed in the late weight-bearing category. No significant difference in Merle d'Aubigné functional scores was found between the 2 groups. No difference was found regarding heterotopic ossification, avascular necrosis, superficial infections, total infections, or osteoarthritis. This systematic review found no difference in functional outcome scores or complication rates between early and late weight-bearing protocols for surgically treated posterior wall fractures. [Orthopedics. 2017: 40(4):e652-e657.]. Copyright 2017, SLACK Incorporated.
Dill, Karli E.; Begalle, Rebecca L.; Frank, Barnett S.; Zinder, Steven M.; Padua, Darin A.
2014-01-01
Context: Ankle-dorsiflexion (DF) range of motion (ROM) may influence movement variables that are known to affect anterior cruciate ligament loading, such as knee valgus and knee flexion. To our knowledge, researchers have not studied individuals with limited or normal ankle DF-ROM to investigate the relationship between those factors and the lower extremity movement patterns associated with anterior cruciate ligament injury. Objective: To determine, using 2 different measurement techniques, whether knee- and ankle-joint kinematics differ between participants with limited and normal ankle DF-ROM. Design: Cross-sectional study. Setting: Sports medicine research laboratory. Patients or Other Participants: Forty physically active adults (20 with limited ankle DF-ROM, 20 with normal ankle DF-ROM). Main Outcome Measure(s): Ankle DF-ROM was assessed using 2 techniques: (1) nonweight-bearing ankle DF-ROM with the knee straight, and (2) weight-bearing lunge (WBL). Knee flexion, knee valgus-varus, knee internal-external rotation, and ankle DF displacements were assessed during the overhead-squat, single-legged squat, and jump-landing tasks. Separate 1-way analyses of variance were performed to determine whether differences in knee- and ankle-joint kinematics existed between the normal and limited groups for each assessment. Results: We observed no differences between the normal and limited groups when classifying groups based on nonweight-bearing passive-ankle DF-ROM. However, individuals with greater ankle DF-ROM during the WBL displayed greater knee-flexion and ankle-DF displacement and peak knee flexion during the overhead-squat and single-legged squat tasks. In addition, those individuals also demonstrated greater knee-varus displacement during the single-legged squat. Conclusions: Greater ankle DF-ROM assessed during the WBL was associated with greater knee-flexion and ankle-DF displacement during both squatting tasks as well as greater knee-varus displacement during the single-legged squat. Assessment of ankle DF-ROM using the WBL provided important insight into compensatory movement patterns during squatting, whereas nonweight-bearing passive ankle DF-ROM did not. Improving ankle DF-ROM during the WBL may be an important intervention for altering high-risk movement patterns commonly associated with noncontact anterior cruciate ligament injury. PMID:25144599
Changes in skeletal muscle gene expression consequent to altered weight bearing
NASA Technical Reports Server (NTRS)
Booth, F. W.; Kirby, C. R.
1992-01-01
Skeletal muscle is a dynamic organ that adapts to alterations in weight bearing. This brief review examines changes in muscle gene expression resulting from the removal of weight bearing by hindlimb suspension and from increased weight bearing due to eccentric exercise. Acute (less than or equal to 2 days) non-weight bearing of adult rat soleus muscle alters only the translational control of muscle gene expression, while chronic (greater than or equal to 7 days) removal of weight bearing appears to influence pretranslational, translational, and posttranslational mechanisms of control. Acute and chronic eccentric exercise are associated with alterations of translational and posttranslational control, while chronic eccentric training also alters the pretranslational control of muscle gene expression. Thus alterations in weight bearing influence multiple sites of gene regulation.
NASA Technical Reports Server (NTRS)
Chappell, Steven P.; Abercromby, Andrew F.; Gernhardt, Michael L.
2011-01-01
The ultimate success of future human space exploration missions is dependent on the ability to perform extravehicular activity (EVA) tasks effectively, efficiently, and safely, whether those tasks represent a nominal mode of operation or a contingency capability. To optimize EVA systems for the best human performance, it is critical to study the effects of varying key factors such as suit center of gravity (CG), suit mass, and gravity level. During the 2-week NASA Extreme Environment Mission Operations (NEEMO) 14 mission, four crewmembers performed a series of EVA tasks under different simulated EVA suit configurations and used full-scale mockups of a Space Exploration Vehicle (SEV) rover and lander. NEEMO is an underwater spaceflight analog that allows a true mission-like operational environment and uses buoyancy effects and added weight to simulate different gravity levels. Quantitative and qualitative data collected during NEEMO 14, as well as from spacesuit tests in parabolic flight and with overhead suspension, are being used to directly inform ongoing hardware and operations concept development of the SEV, exploration EVA systems, and future EVA suits. OBJECTIVE: To compare human performance across different weight and CG configurations. METHODS: Four subjects were weighed out to simulate reduced gravity and wore either a specially designed rig to allow adjustment of CG or a PLSS mockup. Subjects completed tasks including level ambulation, incline/decline ambulation, standing from the kneeling and prone position, picking up objects, shoveling, ladder climbing, incapacitated crewmember handling, and small and large payload transfer. Subjective compensation, exertion, task acceptability, and duration data as well as photo and video were collected. RESULTS: There appear to be interactions between CG, weight, and task. CGs nearest the subject s natural CG are the most predictable in terms of acceptable performance across tasks. Future research should focus on understanding the interactions between CG, mass, and subject differences.
INFLUENCE OF AGE ON NEUROMUSCULAR CONTROL DURING A DYNAMIC WEIGHT BEARING TASK
Madhavan, Sangeetha; Burkart, Sarah; Baggett, Gail; Nelson, Katie; Teckenburg, Trina; Zwanziger, Mike; Shields, Richard K.
2009-01-01
Neuromuscular control strategies may change with age and predispose elderly to knee joint injury. The purposes of this study were to determine if long latency responses (LLR), muscle activation patterns, and movement accuracy differs between the young and elderly during a novel single limb squat (SLS) task. Ten young and ten elderly subjects performed a series of resistive SLS (~0–30 degrees) while matching a computer-generated sinusoidal target. The SLS device provided a 16% body weight resistance to knee movement. Both young and elderly showed significant overshoot error when the knee was perturbed (p < 0.05). Accuracy of the tracking task was similar between the young and elderly (p=0.34), but the elderly required more muscle activity compared to the younger subjects (p < 0.05). The elderly group had larger long latency responses (LLRs) than the younger group (p < 0.05). These results support that neuromuscular control of the knee changes with age, and may contribute to injury. PMID:19799103
Weighted low-rank sparse model via nuclear norm minimization for bearing fault detection
NASA Astrophysics Data System (ADS)
Du, Zhaohui; Chen, Xuefeng; Zhang, Han; Yang, Boyuan; Zhai, Zhi; Yan, Ruqiang
2017-07-01
It is a fundamental task in the machine fault diagnosis community to detect impulsive signatures generated by the localized faults of bearings. The main goal of this paper is to exploit the low-rank physical structure of periodic impulsive features and further establish a weighted low-rank sparse model for bearing fault detection. The proposed model mainly consists of three basic components: an adaptive partition window, a nuclear norm regularization and a weighted sequence. Firstly, due to the periodic repetition mechanism of impulsive feature, an adaptive partition window could be designed to transform the impulsive feature into a data matrix. The highlight of partition window is to accumulate all local feature information and align them. Then, all columns of the data matrix share similar waveforms and a core physical phenomenon arises, i.e., these singular values of the data matrix demonstrates a sparse distribution pattern. Therefore, a nuclear norm regularization is enforced to capture that sparse prior. However, the nuclear norm regularization treats all singular values equally and thus ignores one basic fact that larger singular values have more information volume of impulsive features and should be preserved as much as possible. Therefore, a weighted sequence with adaptively tuning weights inversely proportional to singular amplitude is adopted to guarantee the distribution consistence of large singular values. On the other hand, the proposed model is difficult to solve due to its non-convexity and thus a new algorithm is developed to search one satisfying stationary solution through alternatively implementing one proximal operator operation and least-square fitting. Moreover, the sensitivity analysis and selection principles of algorithmic parameters are comprehensively investigated through a set of numerical experiments, which shows that the proposed method is robust and only has a few adjustable parameters. Lastly, the proposed model is applied to the wind turbine (WT) bearing fault detection and its effectiveness is sufficiently verified. Compared with the current popular bearing fault diagnosis techniques, wavelet analysis and spectral kurtosis, our model achieves a higher diagnostic accuracy.
Kalmet, Pishtiwan H S; Meys, Guido; V Horn, Yvette Y; Evers, Silvia M A A; Seelen, Henk A M; Hustinx, Paul; Janzing, Heinrich; Vd Veen, Alexander; Jaspars, Coen; Sintenie, Jan Bernard; Blokhuis, Taco J; Poeze, Martijn; Brink, Peter R G
2018-02-02
The standard aftercare treatment in surgically treated trauma patients with fractures around or in a joint, known as (peri)- or intra-articular fractures of the lower extremities, is either non-weight bearing or partial weight bearing. We have developed an early permissive weight bearing post-surgery rehabilitation protocol in surgically treated patients with fractures of the lower extremities. In this proposal we want to compare our early permissive weight bearing protocol to the existing current non-weight bearing guidelines in a prospective comparative cohort study. The study is a prospective multicenter comparative cohort study in which two rehabilitation aftercare treatments will be contrasted, i.e. permissive weight bearing and non-weight bearing according to the AO-guideline. The study population consists of patients with a surgically treated fracture of the pelvis/acetabulum or a surgically treated (peri)- or intra-articular fracture of the lower extremities. The inclusion period is 12 months. The duration of follow up is 6 months, with measurements taken at baseline, 2,6,12 and 26 weeks post-surgery. ADL with Lower Extremity Functional Scale. Outcome variables for compliance, as measured with an insole pressure measurement system, encompass peak load and step duration. This study will investigate the (cost-) effectiveness of a permissive weight bearing aftercare protocol. The results will provide evidence whether a permissive weight bearing protocol is more effective than the current non-weight bearing protocol. The study is registered in the Dutch Trial Register ( NTR6077 ). Date of registration: 01-09-2016.
Lack, Simon; Barton, Christian; Woledge, Roger; Laupheimer, Markus; Morrissey, Dylan
2014-11-01
Evidence shows that anti-pronating foot orthoses improve patellofemoral pain, but there is a paucity of evidence concerning mechanisms. We investigated the immediate effects of prefabricated foot orthoses on (i) hip and knee kinematics; (ii) electromyography variables of vastus medialis oblique, vastus lateralis and gluteus medius during a functional step-up task, and (iii) associated clinical measures. Hip muscle activity and kinematics were measured during a step-up task with and without an anti-pronating foot orthoses, in people (n=20, 9 M, 11 F) with patellofemoral pain. Additionally, we measured knee function, foot posture index, isometric hip abductor and knee extensor strength and weight-bearing ankle dorsiflexion. Reduced hip adduction (0.82°, P=0.01), knee internal rotation (0.46°, P=0.03), and decreased gluteus medius peak amplitude (0.9mV, P=0.043) were observed after ground contact in the 'with orthoses' condition. With the addition of orthoses, a more pronated foot posture correlated with earlier vastus medialis oblique onset (r=-0.51, P=0.02) whilst higher Kujala scores correlated with earlier gluteus medius onset (r=0.52, P=0.02). Although small in magnitude, reductions in hip adduction, knee internal rotation and gluteus medius amplitude observed immediately following orthoses application during a task that commonly aggravates symptoms, offer a potential mechanism for their effectiveness in patellofemoral pain management. Given the potential for cumulative effects of weight bearing repetitions completed with a foot orthoses, for example during repeated stair ascent, the differences are likely to be clinically meaningful. Copyright © 2014. Published by Elsevier Ltd.
High Variability of Observed Weight Bearing During Standing Foot and Ankle Radiographs.
Miller, Christopher P; Ghorbanhoseini, Mohammad; Ehrlichman, Lauren K; Walley, Kempland C; Ghaheri, Azadeh; Kwon, John Y
2017-06-01
Weight-bearing radiographs are a critical component of evaluating foot and ankle pathology. An underlying assumption is that patients are placing 50% of their body weight on the affected foot during image acquisition. The accuracy of weight bearing during radiographs is unknown and, presumably, variable, which may result in uncertain ability of the resultant radiographs to appropriately portray the pathology of interest. Fifty subjects were tested. The percentage body weight through the foot of interest was measured at the moment of radiographic image acquisition. The subject was then instructed to bear "half [their] weight" prior to the next radiograph. The percentage body weight was calculated and compared to ideal 50% weight bearing. The mean percentage body weight in trial 1 and 2 was 45.7% ± 3.2% ( P = .012 compared to the 50% mark) and 49.2% ± 2.4%, respectively ( P = .428 compared to 50%). The mean absolute difference in percentage weight bearing compared to 50% in trials 1 and 2 was 9.3% ± 2.3% and 5.8% ± 1.8%, respectively ( P = .005). For trial 1, 18/50 subjects were within the "ideal" (45%-55%) range for weight bearing compared to 32/50 on trial 2 ( P = .005). In trial 1, 24/50 subjects had "appropriate" (>45%) weight bearing compared to 39/50 on trial 2 ( P = .002). There was substantial variability in the weight applied during radiograph acquisition. This study raises questions regarding the assumptions, reliability, and interpretation when evaluating weight-bearing radiographs. Level III, comparative study.
Gene Expression and Structural Skeletal Responses to Long-Duration Simulated Microgravity in Rats
NASA Technical Reports Server (NTRS)
Shirazi-Fard, Yasaman; Rael, Victoria E.; Torres, Samantha; Steczina, Sonette; Bryant, Sheenah; Tahimic, Candice; Globus, Ruth K.
2017-01-01
In this study, we aim to examine skeletal responses to simulated long-duration spaceflight (90 days) and weight-bearing recovery on bone loss using the ground-based hindlimb unloading (HU) model in adolescent (3-month old) male rats. We hypothesized that simulated microgravity leads to the temporal regulation of oxidative defense genes and pro-bone resorption factors, where there is a progression and eventual plateau; furthermore, early transient changes in these pathways precede skeletal adaptations.
Rector, R Scott; Loethen, Joanne; Ruebel, Meghan; Thomas, Tom R; Hinton, Pamela S
2009-10-01
Weight loss improves metabolic fitness and reduces morbidity and mortality; however, weight reduction also reduces bone mineral density (BMD) and increases bone turnover. Weight-bearing aerobic exercise may preserve bone mass and maintain normal bone turnover during weight reduction. We investigated the impact of weight-bearing and nonweight-bearing exercise on serum markers of bone formation and breakdown during short-term, modest weight loss in overweight premenopausal women. Subjects (n = 36) were assigned to 1 of 3 weight-loss interventions designed to produce a 5% reduction in body weight over 6 weeks: (i) energy restriction only (n = 11; DIET); (ii) energy restriction plus nonweight-bearing exercise (n = 12, CYCLE); or (iii) energy restriction plus weight-bearing exercise (n = 13, RUN). Bone turnover markers were measured in serum collected at baseline and after weight loss. All groups achieved a ~5% reduction in body weight (DIET = 5.2%; CYCLE = 5.0%; RUN = 4.7%). Osteocalcin (OC) and C-terminal telopeptide of type I collagen (CTX) increased with weight loss in all 3 groups (p < 0.05), whereas bone alkaline phosphatase was unaltered by the weight-loss interventions. At baseline, OC and CTX were positively correlated (r = 0.36, p = 0.03), but the strength of this association was diminished (r = 0.30, p = 0.06) after weight loss. Modest weight loss, regardless of method, resulted in a significant increase in both OC and CTX. Low-impact, weight-bearing exercise had no effect on serum markers of bone formation or resorption in premenopausal women during weight loss. Future studies that examine the effects of high-impact, weight-bearing activity on bone turnover and BMD during weight loss are warranted.
Schoenmakers, Daphne A L; Feczko, Peter Z; Boonen, Bert; Schotanus, Martijn G M; Kort, Nanne P; Emans, Pieter J
2017-11-01
Previous studies have compared weight-bearing mechanical leg axis (MLA) measurements to non-weight-bearing measurement modalities. Most of these studies compared mean or median values and did not analyse within-person differences between measurements. This study evaluates the within-person agreement of MLA measurements between weight-bearing full-length radiographs (FLR) and non-weight-bearing measurement modalities (computer-assisted surgery (CAS) navigation or MRI). Two independent observers measured the MLA on pre- and postoperative weight-bearing FLR in 168 patients. These measurements were compared to non-weight-bearing measurements obtained by CAS navigation or MRI. Absolute differences in individual subjects were calculated to determine the agreement between measurement modalities. Linear regression was used to evaluate the possibility that other independent variables impact the differences in measurements. A difference was found in preoperative measurements between FLR and CAS navigation (mean of 2.5° with limit of agreement (1.96 SD) of 6.4°), as well as between FLR and MRI measurements (mean of 2.4° with limit of agreement (1.96 SD) of 6.9°). Postoperatively, the mean difference between MLA measured on FLR compared to CAS navigation was 1.5° (limit of agreement (1.96 SD) of 4.6°). Linear regression analysis showed that weight-bearing MLA measurements vary significantly from non-weight-bearing MLA measurements. Differences were more severe in patients with mediolateral instability (p = 0.010), age (p = 0.049) and ≥3° varus or valgus alignment (p = 0.008). The clinical importance of this study lies in the finding that there are within-person differences between weight-bearing and non-weight-bearing measurement modalities. This has implications for preoperative planning, performing total knee arthroplasty (TKA), and clinical follow-up after TKA surgery using CAS navigation or patient-specific instrumentation. III.
Matsushita, Isao; Motomura, Hiraku; Seki, Eiko; Kimura, Tomoatsu
2017-07-01
The long-term effects of tumor necrosis factor (TNF)-blocking therapies on weight-bearing joints in patients with rheumatoid arthritis (RA) have not been fully characterized. The purpose of this study was to assess the radiographic changes of weight-bearing joints in patients with RA during 3-year of TNF-blocking therapies and to identify factors related to the progression of joint damage. Changes in clinical variables and radiological findings in 243 weight-bearing joints (63 hips, 54 knees, 71 ankles, and 55 subtalar joints) in 38 consecutive patients were investigated during three years of treatment with TNF-blocking agents. Multivariate logistic regression analysis was used to identify risk factors for the progression of weight-bearing joint damage. Seventeen (14.5%) of proximal weight-bearing joints (hips and knees) showed apparent radiographic progression during three years of treatment, whereas none of the proximal weight-bearing joints showed radiographic evidence of improvement or repair. In contrast, distal weight-bearing joints (ankle and subtalar joints) displayed radiographic progression and improvement in 20 (15.9%) and 8 (6.3%) joints, respectively. Multivariate logistic analysis for proximal weight-bearing joints identified the baseline Larsen grade (p < 0.001, OR:24.85, 95%CI: 5.07-121.79) and disease activity at one year after treatment (p = 0.003, OR:3.34, 95%CI:1.50-7.46) as independent factors associated with the progression of joint damage. On the other hand, multivariate analysis for distal weight-bearing joints identified disease activity at one year after treatment (p < 0.001, OR:2.13, 95%CI:1.43-3.18) as an independent factor related to the progression of damage. Baseline Larsen grade was strongly associated with the progression of damage in the proximal weight-bearing joints. Disease activity after treatment was an independent factor for progression of damage in proximal and distal weight-bearing joints. Early treatment with TNF-blocking agents and tight control of disease activity are necessary to prevent the progression of damage of the weight-bearing joints.
Patient Compliance with Postoperative Lower-Extremity Non-Weight-Bearing Restrictions.
Chiodo, Christopher P; Macaulay, Alec A; Palms, David A; Smith, Jeremy T; Bluman, Eric M
2016-09-21
A period of non-weight-bearing is prescribed following many orthopaedic injuries and procedures. It is believed that a period of non-weight-bearing is important for proper healing and recovery. The degree to which patients are compliant with non-weight-bearing instructions is unknown. The purpose of this study was to measure patient compliance with a period of prescribed non-weight-bearing. In this single-blinded study, pressure-sensitive film was embedded into short leg casts of 51 consecutive adult orthopaedic patients with unilateral lower-extremity abnormality who had been instructed to be strictly non-weight-bearing. Sensors were retrieved at the time of cast removal (mean, 24.3 days [range, 7 to 48 days]) and then were analyzed for force distribution and magnitude. Noncompliance was defined as maximum detectable pressure exerted on ≥50% of the film. Patient characteristics and the time of year that the casts were worn were also examined to determine if they correlated with weight-bearing. Fourteen (27.5%) of 51 patients were noncompliant with the non-weight-bearing restriction. Six (42.9%) of the 14 noncompliant patients compared with 11 (29.7%) of the 37 compliant patients experienced an adverse event (p = 0.51). Sex, age, language spoken, body mass index, time in the cast, and the treating surgeon did not have a significant influence on weight-bearing performance (p > 0.05). Significantly greater weight-bearing was found (p = 0.04) in warmer months (June to October) than in colder months (November to March) in the United States. The noncompliance rate with the postoperative non-weight-bearing restriction was 27.5% (95% confidence interval, 15.2% to 39.8%) in this patient group, despite explicit instructions and education about possible complications associated with weight-bearing. The only factor found to have a significant effect on weight-bearing compliance was the time of year that the cast was worn. No significant difference was found between the complication rate of the compliant patients and that of the noncompliant patients. Prognostic Level IV. See Instructions for Authors for a complete description of levels of evidence. Copyright © 2016 by The Journal of Bone and Joint Surgery, Incorporated.
NASA Astrophysics Data System (ADS)
Wu, Dongxu; Qiao, Zheng; Wang, Bo; Wang, Huiming; Li, Guo
2014-08-01
In this paper, a four-axis ultra-precision lathe for machining large-scale drum mould with microstructured surface is presented. Firstly, because of the large dimension and weight of drum workpiece, as well as high requirement of machining accuracy, the design guidelines and component parts of this drum lathe is introduced in detail, including control system, moving and driving components, position feedback system and so on. Additionally, the weight of drum workpiece would result in the structural deformation of this lathe, therefore, this paper analyses the effect of structural deformation on machining accuracy by means of ANSYS. The position change is approximately 16.9nm in the X-direction(sensitive direction) which could be negligible. Finally, in order to study the impact of bearing parameters on the load characteristics of aerostatic journal bearing, one of the famous computational fluid dynamics(CFD) software, FLUENT, is adopted, and a series of simulations are carried out. The result shows that the aerostatic spindle has superior performance of carrying capacity and stiffness, it is possible for this lathe to bear the weight of drum workpiece up to 1000kg since there are two aerostatic spindles in the headstock and tailstock.
Gitajn, Ida Leah; Connelly, Daniel; Mascarenhas, Daniel; Breazeale, Stephen; Berger, Peter; Schoonover, Carrie; Martin, Brook; O'Toole, Robert V; Pensy, Raymond; Sciadini, Marcus
2018-02-01
Evaluate whether mortality after discharge is elevated in geriatric fracture patients whose lower extremity weight-bearing is restricted. Retrospective cohort study SETTING: Urban Level 1 trauma center PATIENTS/PARTICIPANTS: 1746 patients >65 years of age INTERVENTION: Post-operative lower extremity weight-bearing status MAIN OUTCOME MEASURE: Mortality, as determined by the Social Security Death Index RESULTS: Univariate analysis demonstrated that patients who were weight-bearing as tolerated on bilateral lower extremities (BLE) had significantly higher 5-year mortality compared to patients with restricted weight-bearing on one lower extremity and restricted weight-bearing on BLE (30%, 21% and 22% respectively, p < 0.001). Cox regression analysis controlling for variables including age, Charlson Comorbidity Index, Injury Severity Scale, combined UE/LE injury, injury mechanism (high vs low), sex, BMI and GCS demonstrated that, in comparison to patients who were weight bearing as tolerated on BLE, restricted weight-bearing on one lower extremity had a hazard ratio (HR) of 0.97 (95% confidence interval 0.78 to 1.20, p = 0.76) and restricted weight-bearing in BLE had a HR of 0.91 (95% confidence interval 0.60 to 1.36, p = 0.73). In geriatric patients, prescribed weight-bearing status did not have a statistically significant association with mortality after discharge, when controlling for age, sex, body mass index, medical comorbidities, Injury Severity Scale (ISS), mechanism of injury, nonoperative treatment and admission GCS. This remained true in when the analysis was restricted to operative injuries only. Copyright © 2017 Elsevier Ltd. All rights reserved.
Kim, Ki-Hyun; Hwangbo, Gak; Kim, Seong-Gil
2015-04-01
[Purpose] The purpose of this study was to access the effect of weight bearing exercise (treadmill exercise) and non-weight-bearing exercise (swimming exercise) on gait in the recovery process after a sciatic nerve crush injury. [Subjects and Methods] Rats were randomly divided into a swimming group (n=3) with non-weight-bearing exercise after a sciatic nerve crush and a treadmill group (n=3) with weight bearing exercise after a sciatic nerve crush. Dartfish is a program that can analyze and interpret motion through video images. The knee lateral epicondyle, lateral malleolus, and metatarsophalangeal joint of the fifth toe were marked by black dots before recording. [Results] There were significant differences in TOK (knee angle toe off) and ICK (knee angle at initial contact) in the swimming group and in TOK, ICA (ankle angle at initial contact), and ICK in the treadmill group. In comparison between groups, there were significant differences in TOA (ankle angle in toe off) and ICA at the 7th day. [Conclusion] There was no difference between weight bearing and non-weight-bearing exercise in sciatic nerve damage, and both exercises accelerated the recovery process in this study.
Song, Young Dong; Jain, Nimash; Kang, Yeon Gwi; Kim, Tae Yune; Kim, Tae Kyun
2016-06-01
Correlations between maximum flexion and functional outcomes in total knee arthroplasty (TKA) patients are reportedly weak. We investigated whether there are differences between passive maximum flexion in nonweight bearing and other types of maximum flexion and whether the type of maximum flexion correlates with functional outcomes. A total of 210 patients (359 knees) underwent preoperative evaluation and postoperative follow-up evaluations (6, 12, and 24 months) for the assessment of clinical outcomes including maximum knee flexion. Maximum flexion was measured under five conditions: passive nonweight bearing, passive weight bearing, active nonweight bearing, and active weight bearing with or without arm support. Data were analyzed for relationships between passive maximum flexion in nonweight bearing by Pearson correlation analyses, and a variance comparison between measurement techniques via paired t test. We observed substantial differences between passive maximum flexion in nonweight bearing and the other four maximum flexion types. At all time points, passive maximum flexion in nonweight bearing correlated poorly with active maximum flexion in weight bearing with or without arm support. Active maximum flexion in weight bearing better correlated with functional outcomes than the other maximum flexion types. Our study suggests active maximum flexion in weight bearing should be reported together with passive maximum flexion in nonweight bearing in research on the knee motion arc after TKA.
Song, Young Dong; Jain, Nimash; Kang, Yeon Gwi; Kim, Tae Yune
2016-01-01
Purpose Correlations between maximum flexion and functional outcomes in total knee arthroplasty (TKA) patients are reportedly weak. We investigated whether there are differences between passive maximum flexion in nonweight bearing and other types of maximum flexion and whether the type of maximum flexion correlates with functional outcomes. Materials and Methods A total of 210 patients (359 knees) underwent preoperative evaluation and postoperative follow-up evaluations (6, 12, and 24 months) for the assessment of clinical outcomes including maximum knee flexion. Maximum flexion was measured under five conditions: passive nonweight bearing, passive weight bearing, active nonweight bearing, and active weight bearing with or without arm support. Data were analyzed for relationships between passive maximum flexion in nonweight bearing by Pearson correlation analyses, and a variance comparison between measurement techniques via paired t test. Results We observed substantial differences between passive maximum flexion in nonweight bearing and the other four maximum flexion types. At all time points, passive maximum flexion in nonweight bearing correlated poorly with active maximum flexion in weight bearing with or without arm support. Active maximum flexion in weight bearing better correlated with functional outcomes than the other maximum flexion types. Conclusions Our study suggests active maximum flexion in weight bearing should be reported together with passive maximum flexion in nonweight bearing in research on the knee motion arc after TKA. PMID:27274468
A novel lunar bed rest analogue.
Cavanagh, Peter R; Rice, Andrea J; Licata, Angelo A; Kuklis, Matthew M; Novotny, Sara C; Genc, Kerim O; Englehaupt, Ricki K; Hanson, Andrea M
2013-11-01
Humans will eventually return to the Moon and thus there is a need for a ground-based analogue to enable the study of physiological adaptations to lunar gravity. An important unanswered question is whether or not living on the lunar surface will provide adequate loading of the musculoskeletal system to prevent or attenuate the bone loss that is seen in microgravity. Previous simulations have involved tilting subjects to an approximately 9.5 degrees angle to achieve a lunar gravity component parallel to the long-axis of the body. However, subjects in these earlier simulations were not weight-bearing, and thus these protocols did not provide an analogue for load on the musculoskeletal system. We present a novel analogue which includes the capability to simulate standing and sitting in a lunar loading environment. A bed oriented at a 9.5 degrees angle was mounted on six linear bearings and was free to travel with one degree of freedom along rails. This allowed approximately 1/6 body weight loading of the feet during standing. "Lunar" sitting was also successfully simulated. A feasibility study demonstrated that the analogue was tolerated by subjects for 6 d of continuous bed rest and that the reaction forces at the feet during periods of standing were a reasonable simulation of lunar standing. During the 6 d, mean change in the volume of the quadriceps muscles was -1.6% +/- 1.7%. The proposed analogue would appear to be an acceptable simulation of lunar gravity and deserves further exploration in studies of longer duration.
Noh, Dong Koog; Lim, Jae-Young; Shin, Hyung-Ik; Paik, Nam-Jong
2008-01-01
To evaluate the effect of an aquatic therapy programme designed to increase balance in stroke survivors. A randomized, controlled pilot trial. Rehabilitation department of a university hospital. Ambulatory chronic stroke patients (n = 25):13 in an aquatic therapy group and 12 in a conventional therapy group. The aquatic therapy group participated in a programme consisting of Ai Chi and Halliwick methods, which focused on balance and weight-bearing exercises. The conventional therapy group performed gym exercises. In both groups, the interventions occurred for 1 hour, three times per week, for eight weeks. The primary outcome measures were Berg Balance Scale score and weight-bearing ability, as measured by vertical ground reaction force during four standing tasks (rising from a chair and weight-shifting forward, backward and laterally). Secondary measures were muscle strength and gait. Compared with the conventional therapy group, the aquatic therapy group attained significant improvements in Berg Balance Scale scores, forward and backward weight-bearing abilities of the affected limbs, and knee flexor strength (P < 0.05), with effect sizes of 1.03, 1.14, 0.72 and 1.13 standard deviation units and powers of 75, 81, 70 and 26%, respectively. There were no significant changes in the other measures between the two groups. Postural balance and knee flexor strength were improved after aquatic therapy based on the Halliwick and Ai Chi methods in stroke survivors. Because of limited power and a small population base, further studies with larger sample sizes are required.
Valkering, Kars P; Aufwerber, Susanna; Ranuccio, Francesco; Lunini, Enricomaria; Edman, Gunnar; Ackermann, Paul W
2017-06-01
Functional weight-bearing mobilization may improve repair of Achilles tendon rupture (ATR), but the underlying mechanisms and outcome were unknown. We hypothesized that functional weight-bearing mobilization by means of increased metabolism could improve both early and long-term healing. In this prospective randomized controlled trial, patients with acute ATR were randomized to either direct post-operative functional weight-bearing mobilization (n = 27) in an orthosis or to non-weight-bearing (n = 29) plaster cast immobilization. During the first two post-operative weeks, 15°-30° of plantar flexion was allowed and encouraged in the functional weight-bearing mobilization group. At 2 weeks, patients in the non-weight-bearing cast immobilization group received a stiff orthosis, while the functional weight-bearing mobilization group continued with increased range of motion. At 6 weeks, all patients discontinued immobilization. At 2 weeks, healing metabolites and markers of procollagen type I (PINP) and III (PIIINP) were examined using microdialysis. At 6 and 12 months, functional outcome using heel-rise test was assessed. Healing tendons of both groups exhibited increased levels of metabolites glutamate, lactate, pyruvate, and of PIIINP (all p < 0.05). Patients in functional weight-bearing mobilization group demonstrated significantly higher concentrations of glutamate compared to the non-weight-bearing cast immobilization group (p = 0.045).The upregulated glutamate levels were significantly correlated with the concentrations of PINP (r = 0.5, p = 0.002) as well as with improved functional outcome at 6 months (r = 0.4; p = 0.014). Heel-rise tests at 6 and 12 months did not display any differences between the two groups. Functional weight-bearing mobilization enhanced the early healing response of ATR. In addition, early ankle range of motion was improved without the risk of Achilles tendon elongation and without altering long-term functional outcome. The relationship between functional weight-bearing mobilization-induced upregulation of glutamate and enhanced healing suggests novel opportunities to optimize post-operative rehabilitation.
Ma, Kunlong; Fang, Yue; Luan, Fujun; Tu, Chongqi; Yang, Tianfu
2012-03-01
To investigate the relationships between residual displacement of weight-bearing and non weight-bearing zones (gap displacement and step displacement) and hip function by analyzing the CT images after reconstruction of acetabular fractures. The CT measures and clinical outcome were retrospectively analyzed from 48 patients with displaced acetabular fracture between June 2004 and June 2009. All patients were treated by open reduction and internal fixation, and were followed up 24 to 72 months (mean, 36 months); all fractures healed after operation. The residual displacement involved the weight-bearing zone in 30 cases (weight-bearing group), and involved the non weight-bearing zone in 18 cases (non weight-bearing group). The clinical outcomes were evaluated by Merle d'Aubigné-Postel criteria, and the reduction of articular surface by CT images, including the maximums of two indexes (gap displacement and step displacement). All the data were analyzed in accordance with the Spearman rank correlation coefficient analysis. There was strong negative correlation between the hip function and the residual displacement values in weight-bearing group (r(s) = -0.722, P = 0.001). But there was no correlation between the hip function and the residual displacement values in non weight-bearing group (r(s) = 0.481, P = 0.059). The results of clinical follow-up were similar to the correlation analysis results. In weight-bearing group, the hip function had strong negative correlation with step displacement (r(s) = 0.825, P = 0.002), but it had no correlation with gap displacement (r(s) = 0.577, P = 0.134). In patients with acetabular fracture, the hip function has correlation not only with the extent of the residual displacement but also with the location of the residual displacement, so the residual displacement of weight-bearing zone is a key factor to affect the hip function. In patients with residual displacement in weight-bearing zone, the bigger the step displacement is, the worse the hip function is.
Dr. von Braun Tries Out the Neutral Buoyancy Simulator (NBS)
NASA Technical Reports Server (NTRS)
1967-01-01
Marshall Space Flight Center (MSFC) Director, Dr. von Braun, submerges after spending some time under water in the MSFC Neutral Buoyancy Simulator (NBS). Weighted to a neutrally buoyant condition, Dr. von Braun was able to perform tasks underwater which simulated weightless conditions found in space.
Lee, O-Sung; Ahn, Soyeon; Lee, Yong Seuk
2017-07-01
The purpose of this systematic review and meta-analysis was to evaluate the effectiveness and safety of early weight-bearing by comparing clinical and radiological outcomes between early and traditional delayed weight-bearing after OWHTO. A rigorous and systematic approach was used. The methodological quality was also assessed. Results that are possible to be compared in two or more than two articles were presented as forest plots. A 95% confidence interval was calculated for each effect size, and we calculated the I 2 statistic, which presents the percentage of total variation attributable to the heterogeneity among studies. The random-effects model was used to calculate the effect size. Six articles were included in the final analysis. All case groups were composed of early full weight-bearing within 2 weeks. All control groups were composed of late full weight-bearing between 6 weeks and 2 months. Pooled analysis was possible for the improvement in Lysholm score, but there was no statistically significant difference shown between groups. Other clinical results were also similar between groups. Four studies reported mechanical femorotibial angle (mFTA) and this result showed no statistically significant difference between groups in the pooled analysis. Furthermore, early weight-bearing showed more favorable results in some radiologic results (osseointegration and patellar height) and complications (thrombophlebitis and recurrence). Our analysis supports that early full weight-bearing after OWHTO using a locking plate leads to improvement in outcomes and was comparable to the delayed weight-bearing in terms of clinical and radiological outcomes. On the contrary, early weight-bearing was more favorable with respect to some radiologic parameters and complications compared with delayed weight-bearing.
Sex-based differences in knee ligament biomechanics during robotically simulated athletic tasks.
Bates, Nathaniel A; Nesbitt, Rebecca J; Shearn, Jason T; Myer, Gregory D; Hewett, Timothy E
2016-06-14
ACL injury rates are greater in female athletes than their male counterparts. As female athletes are at increased risk, it is important to understand the underlying mechanics that contribute to this sex bias. The purpose of this investigation was to employ a robotic manipulator to simulate male and female kinematics from athletic tasks on cadaveric specimens and identify sex-based mechanical differences relative to the ACL loading. It was hypothesized that simulations of female motion would generate the higher loads and ligament strains associated with in vivo ACL injury risk than simulations of male motion. A 6-degree-of-freedom robotic manipulator articulated cadaveric lower extremity specimens from 12 donors through simulations of in vivo kinematics recorded from male and female athletic tasks. Simulation of female kinematics exhibited lower peak lateral joint force during the drop vertical jump and lower peak anterior and lateral joint force and external joint torque during the sidestep cut (P<0.05). Peak ACL strain during a drop vertical jump was 6.27% and 6.61% for the female and male kinematic simulations, respectively (P=0.86). Peak ACL strain during a sidestep cut was 4.33% and 7.57% for female and male kinematic simulations respectively (P=0.21). For the tasks simulated, the sex-based loading and strain differences identified were unlikely to have a significant bearing on the increased rate of ACL injures observed in female athletes. Additional perturbation may be necessary to invoke the mechanisms that lead to higher rates of ACL injury in female populations. Copyright © 2016. Published by Elsevier Ltd.
Changes in muscles accompanying non-weight-bearing and weightlessness
NASA Technical Reports Server (NTRS)
Tischler, M. E.; Henriksen, E. J.; Jaspers, S. R.; Jacob, S.; Kirby, C.
1989-01-01
Results of hindlimb suspension and space flight experiments with rats examine the effects of weightlessness simulation, weightlessness, and delay in postflight recovery of animals. Parameters examined were body mass, protein balance, amino acid metabolism, glucose and glycogen metabolism, and hormone levels. Tables show metabolic responses to unweighting of the soleus muscle.
Health assessment of cooling fan bearings using wavelet-based filtering.
Miao, Qiang; Tang, Chao; Liang, Wei; Pecht, Michael
2012-12-24
As commonly used forced convection air cooling devices in electronics, cooling fans are crucial for guaranteeing the reliability of electronic systems. In a cooling fan assembly, fan bearing failure is a major failure mode that causes excessive vibration, noise, reduction in rotation speed, locked rotor, failure to start, and other problems; therefore, it is necessary to conduct research on the health assessment of cooling fan bearings. This paper presents a vibration-based fan bearing health evaluation method using comblet filtering and exponentially weighted moving average. A new health condition indicator (HCI) for fan bearing degradation assessment is proposed. In order to collect the vibration data for validation of the proposed method, a cooling fan accelerated life test was conducted to simulate the lubricant starvation of fan bearings. A comparison between the proposed method and methods in previous studies (i.e., root mean square, kurtosis, and fault growth parameter) was carried out to assess the performance of the HCI. The analysis results suggest that the HCI can identify incipient fan bearing failures and describe the bearing degradation process. Overall, the work presented in this paper provides a promising method for fan bearing health evaluation and prognosis.
Health Assessment of Cooling Fan Bearings Using Wavelet-Based Filtering
Miao, Qiang; Tang, Chao; Liang, Wei; Pecht, Michael
2013-01-01
As commonly used forced convection air cooling devices in electronics, cooling fans are crucial for guaranteeing the reliability of electronic systems. In a cooling fan assembly, fan bearing failure is a major failure mode that causes excessive vibration, noise, reduction in rotation speed, locked rotor, failure to start, and other problems; therefore, it is necessary to conduct research on the health assessment of cooling fan bearings. This paper presents a vibration-based fan bearing health evaluation method using comblet filtering and exponentially weighted moving average. A new health condition indicator (HCI) for fan bearing degradation assessment is proposed. In order to collect the vibration data for validation of the proposed method, a cooling fan accelerated life test was conducted to simulate the lubricant starvation of fan bearings. A comparison between the proposed method and methods in previous studies (i.e., root mean square, kurtosis, and fault growth parameter) was carried out to assess the performance of the HCI. The analysis results suggest that the HCI can identify incipient fan bearing failures and describe the bearing degradation process. Overall, the work presented in this paper provides a promising method for fan bearing health evaluation and prognosis. PMID:23262486
Oh, Won Seok; Lee, Yong Seuk; Kim, Byung Kak; Sim, Jae Ang; Lee, Beom Koo
2016-06-01
To analyze the contact mechanics of the femoral component and polyethylene of the Low Contact Stress rotating platform (LCS-RP) in nonweight bearing and weight bearing conditions using full flexion lateral radiographs. From May 2009 to December 2013, 58 knees in 41 patients diagnosed with osteoarthritis and treated with total knee arthroplasty (TKA) were included in this study. TKA was performed using an LCS-RP knee prosthesis. Full flexion lateral radiographs in both weight bearing and nonweight bearing condition were taken at least one month postoperatively (average, 28.8 months). Translation of femoral component was determined by the contact point between the femoral component and polyethylene. Maximum flexion was measured as the angle between the lines drawn at the midpoint of the femur and tibia. Posterior shift of the contact point in LCS-RP TKA was observed under weight bearing condition, which resulted in deeper flexion compared to LCS-RP TKA under nonweight bearing condition. In the LCS-RP TKA, the contact point between the femoral component and polyethylene moved posteriorly under weight bearing condition, and the joint was more congruent and maximum flexion increased with weight bearing.
Emitter location errors in electronic recognition system
NASA Astrophysics Data System (ADS)
Matuszewski, Jan; Dikta, Anna
2017-04-01
The paper describes some of the problems associated with emitter location calculations. This aspect is the most important part of the series of tasks in the electronic recognition systems. The basic tasks include: detection of emission of electromagnetic signals, tracking (determining the direction of emitter sources), signal analysis in order to classify different emitter types and the identification of the sources of emission of the same type. The paper presents a brief description of the main methods of emitter localization and the basic mathematical formulae for calculating their location. The errors' estimation has been made to determine the emitter location for three different methods and different scenarios of emitters and direction finding (DF) sensors deployment in the electromagnetic environment. The emitter has been established using a special computer program. On the basis of extensive numerical calculations, the evaluation of precise emitter location in the recognition systems for different configuration alignment of bearing devices and emitter was conducted. The calculations which have been made based on the simulated data for different methods of location are presented in the figures and respective tables. The obtained results demonstrate that calculation of the precise emitter location depends on: the number of DF sensors, the distances between emitter and DF sensors, their mutual location in the reconnaissance area and bearing errors. The precise emitter location varies depending on the number of obtained bearings. The higher the number of bearings, the better the accuracy of calculated emitter location in spite of relatively high bearing errors for each DF sensor.
2011-09-01
years 2 and 3, Cho laboratory) Task 9: Treatment of tumor-bearing mice with cisplatin accompanied by MRI and BLI (completed years 2 and 3, Rehemtulla...and Cho laboratories) Task 10: Treatment of tumor-bearing mice with perifosine accompanied by MRI and BLI (completed, years 2 and 3, Rehemtulla and...Cho laboratories). Task 11: Treatment of tumor-bearing mice with SC-560 accompanied by MRI and BLI (not performed) Task 12: Histological and
Weight bearing of the limb as a confounding factor in assessment of mechanical allodynia in the rat.
Kauppila, T; Kontinen, V K; Pertovaara, A
1998-01-01
Effect of weight bearing of the hindlimbs on the assessment of mechanically-induced hindlimb withdrawal threshold was determined in intact rats and in rats with various pathophysiological conditions causing allodynia or hyperalgesia. Hindlimb withdrawal was elicited by applying a series of calibrated monofilaments to the plantar or the dorsal surface of the paw. During testing the rat was either in a restraint tube with hindlimbs hanging semi-extended without weight bearing or it was standing on a metal grid (bearing its own weight). In intact rats, the withdrawal thresholds were significantly lower when the stimulus site was the dorsal hairy skin rather than the plantar glabrous skin. Also, thresholds were significantly lower when the hindlimbs were not bearing weight. Following carrageenan-induced unilateral inflammation of the plantar paw or a tibial nerve cut there was a marked threshold decrease to test stimuli applied to plantar or dorsal paw, respectively, ipsilateral to the pathological condition in standing rats. However, when the hindlimbs were not weight bearing the unilateral threshold decrease was markedly attenuated (carrageenan-treated rats) or completely abolished (tibial cut). In contrast, in rats with a unilateral spinal nerve ligation the threshold decrease ipsilateral to the nerve lesion was highly significant independent of the weight bearing of the hindlimbs. The results indicate that weight bearing of hindlimbs is an important confounding factor in the assessment of tactile allodynia in rats.
Swart, Eric; Bezhani, Hariklia; Greisberg, Justin; Vosseller, J Turner
2015-01-01
Ankle fractures are common injuries treated routinely by orthopaedic surgeons. A variety of different post-operative protocols have been described with differing periods of non-weight bearing after surgery. The aim of this study was to identify how patient injury characteristics and medical comorbidities contribute to the period of non-weight bearing chosen by orthopaedic surgeons after open reduction and internal fixation of rotational ankle fractures. A cross sectional expert opinion survey was administered to members of the AOFAS as well as OTA to determine how long they would instruct patients to be non-weight bearing after open reduction and internal fixation of ankle fractures. Three different injury characteristics were described: supination external rotation type 4 equivalents, bimalleolar, and trimalleolar patterns. These patterns were combined with three different medical statuses: young and healthy, older and healthy, and older with significant medical comorbidity. Respondents selected how long they would keep the patient non-weight bearing after surgery for each of the potential scenarios. Finally, they were directly asked which factors they felt affected their decision about length of time to keep patients non-weight bearing. Seven hundred and two surgeons (31%) responded to the survey. The average time of non-weight bearing selected varied from 4.9 (± 3.1) weeks for in young, healthy patients with SER4 equivalent injuries to 7.6 (± 6.0) weeks for older patients with medical comorbidities with trimalleolar fractures. Responses had a high degree of heterogeneity, but both injury pattern and medical status were significant predictors of non-weight bearing period (p<0.01), with medical status the stronger determinant. There is significant variation among orthopaedic surgeons when selecting period of non-weight bearing after fixation of ankle fractures, with both injury pattern and medical comorbidity playing a role in decision of time to keep patient non-weight bearing. Further research further evaluating the relationship between these factors and safe periods of non-weight bearing could help identify patients that may benefit from earlier mobilization, and improve surgeon's comfort with early mobilization. Therapeutic Level V. Copyright © 2015 Elsevier Ltd. All rights reserved.
Muscle regeneration during hindlimb unloading results in a reduction in muscle size after reloading
NASA Technical Reports Server (NTRS)
Mozdziak, P. E.; Pulvermacher, P. M.; Schultz, E.
2001-01-01
The hindlimb-unloading model was used to study the ability of muscle injured in a weightless environment to recover after reloading. Satellite cell mitotic activity and DNA unit size were determined in injured and intact soleus muscles from hindlimb-unloaded and age-matched weight-bearing rats at the conclusion of 28 days of hindlimb unloading, 2 wk after reloading, and 9 wk after reloading. The body weights of hindlimb-unloaded rats were significantly (P < 0.05) less than those of weight-bearing rats at the conclusion of hindlimb unloading, but they were the same (P > 0.05) as those of weight-bearing rats 2 and 9 wk after reloading. The soleus muscle weight, soleus muscle weight-to-body weight ratio, myofiber diameter, number of nuclei per millimeter, and DNA unit size were significantly (P < 0.05) smaller for the injured soleus muscles from hindlimb-unloaded rats than for the soleus muscles from weight-bearing rats at each recovery time. Satellite cell mitotic activity was significantly (P < 0.05) higher in the injured soleus muscles from hindlimb-unloaded rats than from weight-bearing rats 2 wk after reloading, but it was the same (P > 0.05) as in the injured soleus muscles from weight-bearing rats 9 wk after reloading. The injured soleus muscles from hindlimb-unloaded rats failed to achieve weight-bearing muscle size 9 wk after reloading, because incomplete compensation for the decrease in myonuclear accretion and DNA unit size expansion occurred during the unloading period.
Dr. von Braun Tries Out the Neutral Buoyancy Simulator (NBS)
NASA Technical Reports Server (NTRS)
1967-01-01
Marshall Space Flight Center (MSFC) Director, Dr. von Braun, is shown leaving the suiting-up van wearing a pressure suit prepared for a tryout in the MSFC Neutral Buoyancy Simulator (NBS). Weighted to a neutrally buoyant condition, Dr. von Braun was able to perform tasks underwater which simulated weightless conditions found in space.
Biomechanical patterns of text-message distraction.
Le, Peter; Hwang, Jaejin; Grawe, Sarah; Li, Jing; Snyder, Alison; Lee, Christina; Marras, William S
2015-01-01
The objective of this study was to identify biomechanical measures that can distinguish texting distraction in a laboratory-simulated driving environment. The goal would be to use this information to provide an intervention for risky driving behaviour. Sixteen subjects participated in this study. Three independent variables were tested: task (texting, visual targeting, weighted and non-weighted movements), task direction (front and side) and task distance (close and far). Dependent variables consisted of biomechanical moments, head displacement and the length of time to complete each task. Results revealed that the time to complete each task was higher for texting compared to other tasks. Peak moments during texting were only distinguishable from visual targeting. Peak head displacement and cumulative biomechanical exposure measures indicated that texting can be distinguished from other tasks. Therefore, it may be useful to take into account both temporal and biomechanical measures when considering warning systems to detect texting distraction.
Lawlor, Mark C; Kluczynski, Melissa A; Marzo, John M
2018-03-01
The utility of computed tomography (CT) for measuring medial clear space (MCS) for determination of the stability of supination external rotation (SER) ankle fractures and in comparison to standard radiographs is unknown. We compared MCS on gravity stress (GS) radiographs to GS and weight bearing (WB) cone-beam CT (CBCT). An AO SER 44B3.1 ankle fracture was simulated in 10 human cadavers, also serving as controls. MCS was measured on GS radiographs, GS CBCT, and a simulated WB CBCT scan. Specimens were stable if MCS was <5 mm and unstable if MCS was ≥5 mm. Paired t tests were used to compare MCS from each imaging modality for controls versus SER injuries and stable versus unstable specimens. Compared with controls assessed by GS radiographs, MCS was greater for an SER injury when assessed by GS radiograph and GS CBCT scan within the stable group. Compared with controls assessed by GS radiographs, MCS was greater for SER injuries when assessed by GS radiograph, GS CBCT scan, and WB CBCT within the unstable group. MCS was reduced for stable versus unstable SER injuries assessed by WB CBCT. In a cadaveric model of SER ankle fracture, the medial clear space was statistically significantly greater for the experimental condition when assessed by gravity stress radiograph and gravity stress CBCT scan. Under weight-bearing conditions, the cone-beam CT scanner distinguished between stable and unstable ankles in the experimental condition. This study suggests that a WB cone-beam CT scan may be able to distinguish between stable and unstable SER ankle fractures and influence operative decision making.
Elhakeem, Ahmed; Hannam, Kimberly; Deere, Kevin C; Hartley, April; Clark, Emma M; Moss, Charlotte; Edwards, Mark H; Dennison, Elaine; Gaysin, Tim; Kuh, Diana; Wong, Andrew; Fox, Kenneth R; Cooper, Cyrus; Cooper, Rachel; Tobias, Jon H
2017-12-01
High impact physical activity (PA) is thought to benefit bone. We examined associations of lifetime walking and weight bearing exercise with accelerometer-measured high impact and overall PA in later life. Data were from 848 participants (66.2% female, mean age = 72.4 years) from the Cohort for Skeletal Health in Bristol and Avon, Hertfordshire Cohort Study and MRC National Survey of Health and Development. Acceleration peaks from seven-day hip-worn accelerometer recordings were used to derive counts of high impact and overall PA. Walking and weight bearing exercise up to age 18, between 18-29, 30-49 and since age 50 were recalled using questionnaires. Responses in each age category were dichotomised and cumulative scores derived. Linear regression was used for analysis. Greater lifetime walking was related to higher overall, but not high impact PA, whereas greater lifetime weight bearing exercise was related to higher overall and high impact PA. For example, fully-adjusted differences in log-overall and log-high impact PA respectively for highest versus lowest lifetime scores were: walking [0.224 (0.087, 0.362) and 0.239 (- 0.058, 0.536)], and weight bearing exercise [0.754 (0.432, 1.076) and 0.587 (0.270, 0.904)]. For both walking and weight bearing exercise, associations were strongest in the 'since age 50' category. Those reporting the most walking and weight bearing exercise since age 50 had highest overall and high impact PA, e.g. fully-adjusted difference in log-high impact PA versus least walking and weight bearing exercise = 0.588 (0.226, 0.951). Promoting walking and weight bearing exercise from midlife may help increase potentially osteogenic PA levels in later life.
Precision Formation Keeping at L2 Using the Autonomous Formation Flying Sensor
NASA Technical Reports Server (NTRS)
McLoughlin, Terence H.; Campbell, Mark
2004-01-01
Recent advances in formation keeping for large numbers of spacecraft using the Autonomous Formation Flying are presented. This sensor, currently under development at JPL, has been identified as a key component in future formation flying spacecraft missions. The sensor provides accurate range and bearing measurements between pairs of spacecraft using GPS technology. Previous theoretical work by the authors has focused on developing a decentralized scheduling algorithm to control the tasking of such a sensor between the relative range and bearing measurements to each node in the formation. The resulting algorithm has been modified to include switching constraints in the sensor. This paper also presents a testbed for real time validation of a sixteen-node formation based on the Stellar Imager mission. Key aspects of the simulation include minimum fuel maneuvers based on free-body dynamics and a three body propagator for simulating the formation at L2.
Array Simulation at the Bearing Stake Sites
1981-04-01
C) The array was generally towed at 300 m depth. Four depth sensors on the array gave depth and tilt. With the exception of Site 1B the array was...Site 2, weights were added to the array to overcome its apparent buoyancy. The depth sensors failed on this run and the actual *ilt is not known. Data...horizontal axis title, " Sensor Group Separation," refers to posicion along che array. It .s equivalent to our simulated receiver depth with shallower
Kato, T; Yamashita, T; Mizutani, S; Honda, A; Matumoto, M; Umemura, Y
2009-12-01
To investigate whether childhood sports participation, particularly weight-bearing sports, has any effect on bone mineral content (BMC), areal bone mineral density (aBMD) and bone geometric characteristics in middle-aged postmenopausal women. Design/ In this cross-sectional comparison of two groups, 46 middle-aged women (mean age, 60.2 (SD 5.6) years; range, 52-73 years) were grouped according to sport participation during growth: weight-bearing sports, including high-impact weight-bearing activities; and low-impact non-weight-bearing sports or no participation. Dual energy X-ray absorptiometry (DXA)-measured BMC, aBMD in the lumbar spine and femur. Magnetic resonance imaging (MRI) determined bone geometric characteristics in the femur, such as femoral mid-diaphyseal cross-sectional area, periosteal and endosteal perimeters and maximum and minimum second moment of area. Postmenopausal middle-aged women with participation in weight-bearing sports during junior high to high school (12-18 years old) displayed significantly greater BMC in both lumbar spine and femoral neck regions, and also significantly greater femoral mid-diaphyseal bone cross-sectional area, periosteal perimeter and maximum and minimum second moment of area than the non-weight-bearing sports group. Adolescent weight-bearing exercise exerts preservational effects on femoral mid-diaphyseal size and shape, while DXA-measured BMC effectively identified the same tendency. Weight-bearing exercise in youth affects bone, and these effects may be preserved as BMC, geometric and structural advantages even after 40 years.
Connell, Louise; Lynott, Dermot
2009-06-01
Color is undeniably important to object representations, but so too is the ability of context to alter the color of an object. The present study examined how implied perceptual information about typical and atypical colors is represented during language comprehension. Participants read sentences that implied a (typical or atypical) color for a target object and then performed a modified Stroop task in which they named the ink color of the target word (typical, atypical, or unrelated). Results showed that color naming was facilitated both when ink color was typical for that object (e.g., bear in brown ink) and when it matched the color implied by the previous sentence (e.g., bear in white ink following Joe was excited to see a bear at the North Pole). These findings suggest that unusual contexts cause people to represent in parallel both typical and scenario-specific perceptual information, and these types of information are discussed in relation to the specialization of perceptual simulations.
Effect of motion inputs on the wear prediction of artificial hip joints
Liu, Feng; Fisher, John; Jin, Zhongmin
2013-01-01
Hip joint simulators have been largely used to assess the wear performance of joint implants. Due to the complexity of joint movement, the motion mechanism adopted in simulators varies. The motion condition is particularly important for ultra-high molecular weight polyethylene (UHMWPE) since polyethylene wear can be substantially increased by the bearing cross-shear motion. Computational wear modelling has been improved recently for the conventional UHMWPE used in total hip joint replacements. A new polyethylene wear law is an explicit function of the contact area of the bearing and the sliding distance, and the effect of multidirectional motion on wear has been quantified by a factor, cross-shear ratio. In this study, the full simulated walking cycle condition based on a walking measurement and two simplified motions, including the ISO standard motion and a simplified ProSim hip simulator motion, were considered as the inputs for wear modelling based on the improved wear model. Both the full simulation and simplified motions generated the comparable multidirectional motion required to reproduce the physiological wear of the bearing in vivo. The predicted volumetric wear of the ProSim simulator motion and the ISO motion conditions for the walking cycle were 13% and 4% lower, respectively, than that of the measured walking condition. The maximum linear wear depths were almost the same, and the areas of the wear depth distribution were 13% and 7% lower for the ProSim simulator and the ISO condition, respectively, compared with that of the measured walking cycle motion condition. PMID:25540472
Arnold, John B; Tu, Chen Gang; Phan, Tri M; Rickman, Mark; Varghese, Viju Daniel; Thewlis, Dominic; Solomon, Lucian B
2017-12-01
To identify and describe the characteristics of existing practices for postoperative weight bearing and management of tibial plateau fractures (TPFs), identify gaps in the literature, and inform the design of future research. Seven electronic databases and clinical trial registers were searched from inception until November 17th 2016. Studies were included if they reported on the surgical management of TPFs, had a mean follow-up time of ≥1year and provided data on postoperative management protocols. Data were extracted and synthesized according to study demographics, patient characteristics and postoperative management (weight bearing regimes, immobilisation devices, exercises and complications). 124 studies were included involving 5156 patients with TPFs. The mean age across studies was 45.1 years (range 20.8-72; 60% male), with a mean follow-up of 34.9 months (range 12-264). The most frequent fracture types were AO/OTA classification 41-B3 (29.5%) and C3 (25%). The most commonly reported non-weight bearing time after surgery was 4-6 weeks (39% of studies), with a further 4-6 weeks of partial weight bearing (51% of studies), resulting in 9-12 weeks before full weight bearing status was recommended (55% of studies). Loading recommendations for initial weight bearing were most commonly toe-touch/<10kg (28%), 10kg-20kg (33%) and progressive (39%). Time to full weight bearing was positively correlated with the proportion of fractures of AO/OTA type C (r=0.465, p=0.029) and Schatzker type IV-VI (r=0.614, p<0.001). Similar rates of rigid (47%) and hinged braces were reported (58%), most frequently for 3-6 weeks (43% of studies). Complication rates averaged 2% of patients (range 0-26%) for abnormal varus/valgus and 1% (range 0-22%) for non-union or delayed union. Postoperative rehabilitation for TPFs most commonly involves significant non-weight bearing time before full weight bearing is recommended at 9-12 weeks. Partial weight bearing protocols and brace use were varied. Type of rehabilitation may be an important factor influencing recovery, with future high quality prospective studies required to determine the impact of different protocols on clinical and radiological outcomes. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Kawamura, K.; Beale, G. O.; Schaffer, J. D.; Hsieh, B. J.; Padalkar, S.; Rodriguez-Moscoso, J. J.
1985-01-01
The results of the first phase of Research on an Expert System for Database Operation of Simulation/Emulation Math Models, is described. Techniques from artificial intelligence (AI) were to bear on task domains of interest to NASA Marshall Space Flight Center. One such domain is simulation of spacecraft attitude control systems. Two related software systems were developed to and delivered to NASA. One was a generic simulation model for spacecraft attitude control, written in FORTRAN. The second was an expert system which understands the usage of a class of spacecraft attitude control simulation software and can assist the user in running the software. This NASA Expert Simulation System (NESS), written in LISP, contains general knowledge about digital simulation, specific knowledge about the simulation software, and self knowledge.
Induced sadness increases persistence in a simulated slot machine task among recreational gamblers.
Devos, Gaëtan; Clark, Luke; Maurage, Pierre; Billieux, Joël
2018-05-01
Gambling may constitute a strategy for coping with depressive mood, but a direct influence of depressive mood on gambling behaviors has never been tested via realistic experimental designs in gamblers. The current study tested whether experimentally induced sadness increases persistence on a simulated slot machine task using real monetary reinforcement in recreational gamblers. Sixty participants were randomly assigned to an experimental (sadness induction) or control (no emotional induction) condition, and then performed a slot machine task consisting of a mandatory phase followed by a persistence phase. Potential confounding variables (problem gambling symptoms, impulsivity traits, gambling cognitions) were measured to ensure that the experimental and control groups were comparable. The study showed that participants in the sadness condition displayed greater gambling persistence than control participants (p = .011). These data support the causal role of negative affect in decisions to gamble and persistence, which bears important theoretical and clinical implications. (PsycINFO Database Record (c) 2018 APA, all rights reserved).
Gilleard, W; Smith, T
2007-02-01
Effects of obesity on trunk forward flexion motion in sitting and standing, and postural adaptations and hip joint moment for a standing work task. Cross-sectional comparison of obese and normal weight groups. Ten obese subjects (waist girth 121.2+/-16.8 cm, body mass index (BMI) 38.9+/-6.6 kg m(-2)) and 10 age- and height-matched normal weight subjects (waist girth 79.6+/-6.4 cm, BMI 21.7+/-1.5 kg m(-2)). Trunk motion during seated and standing forward flexion, and trunk posture, hip joint moment and hip-to-bench distance during a simulated standing work task were recorded. Forward flexion motion of the thoracic segment and thoracolumbar spine was decreased for the obese group with no change in pelvic segment and hip joint motion. Obese subjects showed a more flexed trunk posture and increased hip joint moment and hip-to-bench distance for a simulated standing work task. Decreased range of forward flexion motion, differing effects within the trunk, altered posture during a standing work task and concomitant increases in hip joint moment give insight into the aetiology of functional decrements and musculoskeletal pain seen in obesity.
Foot kinematics and loading of professional athletes in American football-specific tasks.
Riley, Patrick O; Kent, Richard W; Dierks, Tracy A; Lievers, W Brent; Frimenko, Rebecca E; Crandall, Jeff R
2013-09-01
The purpose of this study was to describe stance foot and ankle kinematics and the associated ground reaction forces at the upper end of human performance in professional football players during commonly performed football-specific tasks. Nine participants were recruited from the spring training squad of a professional football team. In a motion analysis laboratory setting, participants performed three activities used at the NFL Scouting Combine to assess player speed and agility: the 3-cone drill, the shuttle run, and the standing high jump. The talocrural and first metatarsophalangial joint dorsiflexion, subtalar joint inversion, and the ground reaction forces were determined for the load bearing portions of each activity. We documented load-bearing foot and ankle kinematics of elite football players performing competition-simulating activities, and confirmed our hypothesis that the talocrural, subtalar, and metatarsophalangeal joint ranges of motion for the activities studied approached or exceeded reported physiological limits. Copyright © 2012 Elsevier B.V. All rights reserved.
Haptic biofeedback for improving compliance with lower-extremity partial weight bearing.
Fu, Michael C; DeLuke, Levi; Buerba, Rafael A; Fan, Richard E; Zheng, Ying Jean; Leslie, Michael P; Baumgaertner, Michael R; Grauer, Jonathan N
2014-11-01
After lower-extremity orthopedic trauma and surgery, patients are often advised to restrict weight bearing on the affected limb. Conventional training methods are not effective at enabling patients to comply with recommendations for partial weight bearing. The current study assessed a novel method of using real-time haptic (vibratory/vibrotactile) biofeedback to improve compliance with instructions for partial weight bearing. Thirty healthy, asymptomatic participants were randomized into 1 of 3 groups: verbal instruction, bathroom scale training, and haptic biofeedback. Participants were instructed to restrict lower-extremity weight bearing in a walking boot with crutches to 25 lb, with an acceptable range of 15 to 35 lb. A custom weight bearing sensor and biofeedback system was attached to all participants, but only those in the haptic biofeedback group were given a vibrotactile signal if they exceeded the acceptable range. Weight bearing in all groups was measured with a separate validated commercial system. The verbal instruction group bore an average of 60.3±30.5 lb (mean±standard deviation). The bathroom scale group averaged 43.8±17.2 lb, whereas the haptic biofeedback group averaged 22.4±9.1 lb (P<.05). As a percentage of body weight, the verbal instruction group averaged 40.2±19.3%, the bathroom scale group averaged 32.5±16.9%, and the haptic biofeedback group averaged 14.5±6.3% (P<.05). In this initial evaluation of the use of haptic biofeedback to improve compliance with lower-extremity partial weight bearing, haptic biofeedback was superior to conventional physical therapy methods. Further studies in patients with clinical orthopedic trauma are warranted. Copyright 2014, SLACK Incorporated.
Skou, Nikolaj; Egund, Niels
2017-03-01
Background Diagnosis and treatment of patellofemoral disorders including osteoarthritis are currently often based on imaging and clinical assessment with patients in the supine position. Purpose To evaluate differences in patellar position in the trochlear groove and to assess the detection of medial and lateral patellofemoral (PF) osteoarthritis (OA) on axial radiographs in supine and standing positions, respectively. Material and Methods Thirty-five women and 23 men (mean age, 56 years; age range, 18-87 years) referred for routine radiographic examinations of the knees were included. Axial radiographs of the PF joint in both supine non-weight-bearing and standing weight-bearing position in 30° knee flexion were obtained of 111 knees. Measurements performed on the radiographs: patellar tilt, patellar displacement, joint space width, and grade of OA according to Ahlbäck. Results From supine to standing position the patella moved medially and medial joint space width and lateral patellar tilt angle decreased ( P < 0.0001 for the three measured parameters). In the standing position, medial PF OA was observed in 19 knees compared to three knees in the supine position. Fourteen knees had lateral PF OA with almost unchanged grade of OA irrespective of position. Conclusion In weight-bearing positions, the patella is positioned medially in the trochlear groove compared to supine non-weight-bearing positions. Therefore, this study suggests that the common occurrence of medial PF OA can generally not be detected on axial radiographs in supine non-weight-bearing positions and confirms the importance of imaging the PF joint in standing weight-bearing positions.
Nakagawa, Theresa H; Muniz, Thiago B; Baldon, Rodrigo M; Maciel, Carlos D; Amorim, César F; Serrão, Fábio V
2011-01-01
Proximal factors have been proposed to influence the biomechanics of the patellofemoral joint. A delayed or diminished gluteus medius (GM) activation, before the foot contact on the ground during functional activities could lead to excessive femur adduction and internal rotation and be associated with anterior knee pain (AKP). There are few studies on this topic and the results were inconclusive, therefore, it is necessary to investigate the GM preactivation pattern during functional activities. To compare the GM electromyographic (EMG) preactivation pattern during walking, descending stairs and in single leg jump task in women with and without AKP. Nine women clinically diagnosed with AKP and ten control subjects with no history of knee injury participated in this study. We evaluated GM EMG linear envelope before the foot contact on the ground during walking and GM onset time and EMG linear envelope during descending stairs as well as in a single leg vertical jump. Mann-Whitney U tests were used to determine the between-group differences in GM EMG preactivation pattern. No between-group differences were observed in GM linear envelope during walking (P=0.41), GM onset time and linear envelope during descending stairs (P=0.17 and P=0.15) and single leg jump (P=0.81 and P=0.33). Women with AKP did not demonstrated altered GM preactivation pattern during functional weight bearing activities. Our results did not support the hypothesis that poor GM preactivation pattern could be associated with AKP.
Biofeedback in Partial Weight Bearing: Validity of 3 Different Devices.
van Lieshout, Remko; Stukstette, Mirelle J; de Bie, Rob A; Vanwanseele, Benedicte; Pisters, Martijn F
2016-11-01
Study Design Controlled laboratory study to assess criterion-related validity, with a cross-sectional within-subject design. Background Patients with orthopaedic conditions have difficulties complying with partial weight-bearing instructions. Technological advances have resulted in biofeedback devices that offer real-time feedback. However, the accuracy of these devices is mostly unknown. Inaccurate feedback can result in incorrect lower-limb loading and may lead to delayed healing. Objectives To investigate validity of peak force measurements obtained using 3 different biofeedback devices under varying levels of partial weight-bearing categories. Methods Validity of 3 biofeedback devices (OpenGo science, SmartStep, and SensiStep) was assessed. Healthy participants were instructed to walk at a self-selected speed with crutches under 3 different weight-bearing conditions, categorized as a percentage range of body weight: 1% to 20%, greater than 20% to 50%, and greater than 50% to 75%. Peak force data from the biofeedback devices were compared with the peak vertical ground reaction force measured with a force plate. Criterion validity was estimated using simple and regression-based Bland-Altman 95% limits of agreement and weighted kappas. Results Fifty-five healthy adults (58% male) participated. Agreement with the gold standard was substantial for the SmartStep, moderate for OpenGo science, and slight for SensiStep (weighted ± = 0.76, 0.58, and 0.19, respectively). For the 1% to 20% and greater than 20% to 50% weight-bearing categories, both the OpenGo science and SmartStep had acceptable limits of agreement. For the weight-bearing category greater than 50% to 75%, none of the devices had acceptable agreement. Conclusion The OpenGo science and SmartStep provided valid feedback in the lower weight-bearing categories, and the SensiStep showed poor validity of feedback in all weight-bearing categories. J Orthop Sports Phys Ther 2016;46(11):-1. Epub 12 Oct 2016. doi:10.2519/jospt.2016.6625.
Support system, excavation arrangement, and process of supporting an object
DOE Office of Scientific and Technical Information (OSTI.GOV)
Arnold, Bill W.
2017-08-01
A support system, an excavation arrangement, and a process of supporting an object are disclosed. The support system includes a weight-bearing device and a camming mechanism positioned below the weight-bearing device. A downward force on the weight-bearing device at least partially secures the camming mechanism to opposing surfaces. The excavation arrangement includes a borehole, a support system positioned within and secured to the borehole, and an object positioned on and supported by the support system. The process includes positioning and securing the support system and positioning the object on the weight-bearing device.
Dr. von Braun Tries Out the NBS
NASA Technical Reports Server (NTRS)
1967-01-01
Marshall Space Flight Center (MSFC) Director, Dr. von Braun, is shown fitted with suit and diving equipment as he prepares for a tryout in the MSFC Neutral Buoyancy Simulator (NBS). Weighted to a neutrally buoyant condition, Dr. von Braun was able to perform tasks underwater which simulated weightless conditions found in space.
2011-09-01
Treatment of tumor-bearing mice with cisplatin accompanied by MRI and BLI (completed years 2 and 3, Rehemtulla and Cho laboratories) Task 10: Treatment...of tumor-bearing mice with perifosine accompanied by MRI and BLI (completed, years 2 and 3, Rehemtulla and Cho laboratories). Task 11: Treatment of...tumor-bearing mice with SC-560 accompanied by MRI and BLI (not performed) Task 12: Histological and immunohistochemical analysis of β-catenin
Martins, Emerson Fachin; de Araujo Barbosa, Paulo Henrique Ferreira; de Menezes, Lidiane Teles; de Sousa, Pedro Henrique Côrtes; Costa, Abraão Souza
2011-11-01
Injuries may cause unilateral deterioration of brain areas related to postural control resulting in lateralized motor disability with abnormal asymmetry in weight-bearing distribution. Although overloading toward the nonaffected limb has been described as the preferred posture among individuals with hemiparesis, characterization of the weight-bearing asymmetry is poorly and indirectly described. Therefore, this study aimed to describe weight-bearing distribution during upright stance, establishing criteria to consider asymmetry in hemiparesis when analyzed within the limits defined by controls matched by age and gender. Forty subjects with (n = 20) or without hemiparesis (n = 20) were included in procedures to record weight-bearing values between hemibodies, and these values were used to calculate a symmetry ratio. Control presented 95% confidence interval (CI) of the mean for symmetry ratio ranging from 0.888 to 1.072, defining limits to symmetry. Four subjects with hemiparesis (20%) had symmetry ratios inside limits defined by controls (i.e., weight-bearing symmetrically distributed), and 11 (55%) subjects without hemiparesis showed symmetry ratios outside the limits, suggesting asymmetrical weight-bearing distribution. It was concluded that asymmetry, when present in a control group, was more frequently overloading nonpredominantly used hemibody (nondominant side), differing from a hemiparesis group commonly forced to assume the nonaffected side as the predominantly used hemibody and where the overload was observed.
Tang, Liang; Gao, Xiaohang; Yang, Xiaoying; Zhang, Didi; Zhang, Xiaojun; Du, Haiping; Han, Yanqi; Sun, Lijun
2016-12-01
Weight-bearing exercise is beneficial to bone health. Myostatin (MSTN) deficiency has a positive effect on bone formation. We wondered if a combination of weight-bearing training and polyclonal antibody for MSTN (MsAb) would augment bone formation to a greater degree than single treatment. In this study, rats were randomly assigned to four groups: Control, weight-bearing training (WT), MsAb, and WT+MsAb. The trained rats ran at 15 m/min bearing with 35% of their body weight, 40 min/day (2 min of running followed by 2 min of rest), 6 days/week, for 8 weeks. The rats with MsAb were injected once a week with MsAb for 8 weeks. MicroCT analysis showed that compared with the MsAb group, WT+MsAb significantly enhanced cortical bone mineral density (BMD) (p < .01), bone volume over total volume (BV/TV) (p < .01), trabecular thickness (p < .05), and reduced trabecular separation (Tb.Sp) (p < .01). Compared with the WT group, WT+MsAb significantly increased trabecular BMD (p < .05), BV/TV (p < .05), and decreased Tb.Sp (p < .05). Three-point bending test demonstrated that MsAb failed to improve bone biomechanical properties (p > .05), weight-bearing training significantly increased energy absorption (p < .05) and elastic modulus (p < .05). However, when they combined, biomechanical properties including maximum load (p < .05), stiffness (p < .05), elastic modulus (p < .01) and energy absorption (p < .01) were all significantly enhanced. In conclusion, the combination of weight-bearing training and MsAb have a greater positive effect on bone than treatment with either MsAb or weight-bearing training alone, suggesting that resistance training in combination with MSTN antagonists could be an effective approach for improving bone health and reducing osteoporosis risk.
Becher, Christoph; Fleischer, Benjamin; Rase, Marten; Schumacher, Thees; Ettinger, Max; Ostermeier, Sven; Smith, Tomas
2017-08-01
This study analysed the effects of upright weight bearing and the knee flexion angle on patellofemoral indices, determined using magnetic resonance imaging (MRI), in patients with patellofemoral instability (PI). Healthy volunteers (control group, n = 9) and PI patients (PI group, n = 16) were scanned in an open-configuration MRI scanner during upright weight bearing and supine non-weight bearing positions at full extension (0° flexion) and at 15°, 30°, and 45° flexion. Patellofemoral indices included the Insall-Salvati Index, Caton-Deschamp Index, and Patellotrochlear Index (PTI) to determine patellar height and the patellar tilt angle (PTA), bisect offset (BO), and the tibial tubercle-trochlear groove (TT-TG) distance to assess patellar rotation and translation with respect to the femur and alignment of the extensor mechanism. A significant interaction effect of weight bearing by flexion angle was observed for the PTI, PTA, and BO for subjects with PI. At full extension, post hoc pairwise comparisons revealed a significant effect of weight bearing on the indices, with increased patellar height and increased PTA and BO in the PI group. Except for the BO, no such changes were seen in the control group. Independent of weight bearing, flexing the knee caused the PTA, BO, and TT-TG distance to be significantly reduced. Upright weight bearing and the knee flexion angle affected patellofemoral MRI indices in PI patients, with significantly increased values at full extension. The observations of this study provide a caution to be considered by professionals when treating PI patients. These patients should be evaluated clinically and radiographically at full extension and various flexion angles in context with quadriceps engagement. Explorative case-control study, Level III.
Hicks, D A; Millis, D L
2014-01-01
To determine ground reaction forces, head and pelvis vertical motion (HVM and PVM, respectively), and thoraco-lumbar lateral angular motion (LAM) of the spine using kinematic gait analysis in dogs with mild asymmetric weight-bearing of the pelvic limbs while trotting. Twenty-seven hound-type dogs were fitted with reflective markers placed on the sagittal crest of the skull, the ischiatic tuberosity, and thoracolumbar spine of dogs to track motion while trotting. Kinetic and kinematic data were used to characterize asymmetry between the left and right pelvic limbs, and to describe HVM, PVM and thoraco-lumbar LAM. Maximum and minimum position and total motion values were determined for each measured variable. Dogs with asymmetric weight bearing of the pelvic limbs had greater PVM on the side with a greater peak vertical force (PVF), and greater thoraco-lumbar LAM toward the side with a lower PVF while trotting. No differences in mean HVM were detected, and there were no significant correlations between the magnitude of HVM, PVM and thoraco-lumbar LAM and the degree of asymmetric weight bearing. Dogs with subtle asymmetric weight bearing of a pelvic limb had patterns of body motion that may be useful in identifying subtle lameness in dogs; greater PVM on the side with greater weight bearing and greater thoraco-lumbar LAM toward the side with less weight bearing while trotting. Description of these compensatory movements is valuable when evaluating dogs with subtle weight bearing asymmetry in the pelvic limbs and may improve the sensitivity of lameness detection during subjective clinical lameness examination.
Verification of accurate technical insight: a prerequisite for self-directed surgical training.
Hu, Yinin; Kim, Helen; Mahmutovic, Adela; Choi, Joanna; Le, Ivy; Rasmussen, Sara
2015-03-01
Simulation-based surgical skills training during preclinical education is a persistent challenge due to time constraints of trainees and instructors alike. Self-directed practice is resource-efficient and flexible; however, insight into technical proficiency among trainees is often lacking. The purpose of this study is to prospectively assess the accuracy of self-assessments among medical students learning basic surgical suturing. Over seven weekly practice sessions, preclinical medical students performed serial repetitions of a simulation-based suturing task under one-on-one observation by one of four trainers. Following each task repetition, self- and trainer-assessments (SA-TA) were performed using a 36-point weighted checklist of technical standards developed a priori by expert consensus. Upon study completion, agreement between SA and TA was measured using weighted Cohen's kappa coefficients. Twenty-nine medical students each performed a median of 25 suture task repetitions (IQR 21.5-28). Self-assessments tended to overestimate proficiency during the first tertile of practice attempts. Agreement between SA and TA improved with experience, such that the weighted kappa statistics for the two-handed and instrument ties were >0.81 after 18-21 task attempts. Inexperienced trainees frequently overestimate technical proficiency through self-assessments. However, this bias diminishes with repetitive practice. Only after trainees have attained the capacity to accurately self-assess can effective self-directed learning take place.
Perkins, Bryan; Gronbeck, Kyle R; Yue, Ruixian Alexander; Tompkins, Marc A
2017-08-16
Post-operative weight bearing after meniscal repair is a point of debate among physicians. This study sought to evaluate whether patients adhering to an immediate WBAT rehabilitation programme have a higher failure rate compared to those adhering to a more traditional, protected, NWB status following meniscal repair. The null hypothesis was that there would be no difference in failure between the two groups. A retrospective review of meniscal repair patients greater than 5 years from surgery was performed for patients receiving meniscal repair treatment. Patients were categorized by post-surgical weight-bearing status, either NWB or WBAT, and then analysed for failure of repair. Failure was defined as re-operation on the torn meniscus. The study controlled for variables including age at surgery, sex, height, weight, and BMI, classification of tear type, acuity of the tear, repair location (medial or lateral), repair location within the meniscus, repair technique, and concomitant procedures. Re-operations were performed in 61 of 157 patients [38.9%]. There was no difference between weight-bearing groups for failure of meniscus repair (n.s.). The tears were acute vertical tears located in the posterior horn and body. For the 61 patients with re-operation, the average time to re-operation was 2.2 years with 10 [16%] > 5 years from surgery, 17 [28%] 2-5 years from surgery, and 34 [56%] < 2 years from surgery. In isolated meniscal repair patients (n = 62), there was no difference between weight-bearing groups for rate of re-operation (n.s.). Weight bearing as tolerated after meniscal repair for peripheral, vertical tears does not result in a higher failure rate than traditional, non-weight bearing over a five-year follow-up period. The clinical relevance is that, based on these data, it may be appropriate to allow weight bearing as tolerated following meniscal repair of peripheral, vertical tears. Retrospective cohort study, Level III.
A novel method to determine the elastic modulus of extremely soft materials.
Stirling, Tamás; Zrínyi, Miklós
2015-06-07
Determination of the elastic moduli of extremely soft materials that may deform under their own weight is a rather difficult experimental task. A new method has been elaborated by means of which the elastic modulus of such materials can be determined. This method is generally applicable to all soft materials with purely neo-Hookean elastic deformation behaviour with elastic moduli lower than 1 kPa. Our novel method utilises the self-deformation of pendent gel cylinders under gravity. When suspended, the material at the very top bears the weight of the entire gel cylinder, but that at the bottom carries no load at all. Due to the non-uniform stress distribution along the gel sample both the stress and the resulting strain show position dependence. The cross-sectional area of the material is lowest at the top of the sample and gradually increases towards its bottom. The equilibrium geometry of the pendant gel is used to evaluate the elastic modulus. Experimental data obtained by the proposed new method were compared to the results obtained from underwater measurements. The parameters affecting the measurement uncertainty were studied by a Pareto analysis of a series of adaptive Monte Carlo simulations. It has been shown that our method provides an easily achievable method to provide an accurate determination of the elastic modulus of extremely soft matter typically applicable for moduli below 1 kPa.
Advanced Aerospace Materials by Design
NASA Technical Reports Server (NTRS)
Srivastava, Deepak; Djomehri, Jahed; Wei, Chen-Yu
2004-01-01
The advances in the emerging field of nanophase thermal and structural composite materials; materials with embedded sensors and actuators for morphing structures; light-weight composite materials for energy and power storage; and large surface area materials for in-situ resource generation and waste recycling, are expected to :revolutionize the capabilities of virtually every system comprising of future robotic and :human moon and mars exploration missions. A high-performance multiscale simulation platform, including the computational capabilities and resources of Columbia - the new supercomputer, is being developed to discover, validate, and prototype next generation (of such advanced materials. This exhibit will describe the porting and scaling of multiscale 'physics based core computer simulation codes for discovering and designing carbon nanotube-polymer composite materials for light-weight load bearing structural and 'thermal protection applications.
NASA Astrophysics Data System (ADS)
Wang, Qian
Development of automotive engines with high power output demands the application of high strength materials with good tribological properties. Metal matrix composites (MMC's) and some nitrogen ceramics are of interest to replace some conventional materials in the piston/pin/connecting rod design. A simulation study has been developed to explore the possibility to employ MMC's as bearing materials and ceramics as journal materials, and to investigate the related wear mechanisms and the possible journal bearing failure mechanisms. Conventional tin coated Al-Si alloy (Al-Si/Sn) have been studied for the base line information. A mixed lubrication model for journal bearing with a soft coating has been developed and applied to the contact and temperature analysis of the Al-Si/Sn bearing. Experimental studies were performed to reveal the bearing friction and wear behavior. Tin coating exhibited great a advantage in friction reduction, however, it suffered significant wear through pitting and debonding. When the tin wore out, the Al-Si/steel contact experienced higher friction. A cast and P/M MMC's in the lubricated contact with case hardened steel and ceramic journals were studied experimentally. Without sufficient material removal in the conformal contact situation, MMC bearings in the MMC/steel pairs gained weight due to iron transfer and surface tribochemical reactions with the lubricant additives and contact failure occurred. However, the MMC/ceramic contacts demonstrated promising tribological behavior with low friction and high wear resistance, and should be considered for new journal bearing design. Ceramics are wear resistant. Ceramic surface roughness is very crucial when the journals are in contact with the tin coated bearings. In contact with MMC bearings, ceramic surface quality and fracture toughness seem to play some important roles in affecting the friction coefficient. The wear of silicon nitride and beta sialon (A) journals is pitting due to grain boundary fracture and grain pull-out.
Kutzner, Ines; Dymke, Jörn; Damm, Philipp; Duda, Georg N.; Günzl, Reiner; Bergmann, Georg
2017-01-01
Aquatic exercises are widely used for rehabilitation or preventive therapies in order to enable mobilization and muscle strengthening while minimizing joint loading of the lower limb. The load reducing effect of water due to buoyancy is a main advantage compared to exercises on land. However, also drag forces have to be considered that act opposite to the relative motion of the body segments and require higher muscle activity. Due to these opposing effects on joint loading, the load-reducing effect during aquatic exercises remains unknown. The aim of this study was to quantify the joint loads during various aquatic exercises and to determine the load reducing effect of water. Instrumented knee and hip implants with telemetric data transfer were used to measure the resultant joint contact forces in 12 elderly subjects (6x hip, 6x knee) in vivo. Different dynamic, weight-bearing and non-weight-bearing activities were performed by the subjects on land and in chest-high water. Non-weight-bearing hip and knee flexion/extension was performed at different velocities and with additional Aquafins. Joint forces during aquatic exercises ranged between 32 and 396% body weight (BW). Highest forces occurred during dynamic activities, followed by weight-bearing and slow non-weight-bearing activities. Compared to the same activities on land, joint forces were reduced by 36–55% in water with absolute reductions being greater than 100%BW during weight-bearing and dynamic activities. During non-weight-bearing activities, high movement velocities and additional Aquafins increased the joint forces by up to 59% and resulted in joint forces of up to 301%BW. This study confirms the load reducing effect of water during weight-bearing and dynamic exercises. Nevertheless, high drag forces result in increased joint contact forces and indicate greater muscle activity. By the choice of activity, movement velocity and additional resistive devices joint forces can be modulated individually in the course of rehabilitation or preventive therapies. PMID:28319145
Kutzner, Ines; Richter, Anja; Gordt, Katharina; Dymke, Jörn; Damm, Philipp; Duda, Georg N; Günzl, Reiner; Bergmann, Georg
2017-01-01
Aquatic exercises are widely used for rehabilitation or preventive therapies in order to enable mobilization and muscle strengthening while minimizing joint loading of the lower limb. The load reducing effect of water due to buoyancy is a main advantage compared to exercises on land. However, also drag forces have to be considered that act opposite to the relative motion of the body segments and require higher muscle activity. Due to these opposing effects on joint loading, the load-reducing effect during aquatic exercises remains unknown. The aim of this study was to quantify the joint loads during various aquatic exercises and to determine the load reducing effect of water. Instrumented knee and hip implants with telemetric data transfer were used to measure the resultant joint contact forces in 12 elderly subjects (6x hip, 6x knee) in vivo. Different dynamic, weight-bearing and non-weight-bearing activities were performed by the subjects on land and in chest-high water. Non-weight-bearing hip and knee flexion/extension was performed at different velocities and with additional Aquafins. Joint forces during aquatic exercises ranged between 32 and 396% body weight (BW). Highest forces occurred during dynamic activities, followed by weight-bearing and slow non-weight-bearing activities. Compared to the same activities on land, joint forces were reduced by 36-55% in water with absolute reductions being greater than 100%BW during weight-bearing and dynamic activities. During non-weight-bearing activities, high movement velocities and additional Aquafins increased the joint forces by up to 59% and resulted in joint forces of up to 301%BW. This study confirms the load reducing effect of water during weight-bearing and dynamic exercises. Nevertheless, high drag forces result in increased joint contact forces and indicate greater muscle activity. By the choice of activity, movement velocity and additional resistive devices joint forces can be modulated individually in the course of rehabilitation or preventive therapies.
Dr. von Braun Tries Out the Neutral Buoyancy Simulator (NBS)
NASA Technical Reports Server (NTRS)
1967-01-01
Astronaut L. Gordon Cooper checks the neck ring of a space suit worn by Marshall Space Flight Center (MSFC) Director, Dr. von Braun before he submerges into the water of the MSFC Neutral Buoyancy Simulator (NBS). Wearing a pressurized suit and weighted to a neutrally buoyant condition, Dr. von Braun was able to perform tasks underwater which simulated weightless conditions found in space.
Jacobs, Jeremy M.; Evanson, J. Richard; Pniewski, Josh; Dickston, Michelle L.; Mueller, Terry; Bojescul, John A.
2017-01-01
Introduction Hip arthroscopy allows surgeons to address intra-articular pathology of the hip while avoiding more invasive open surgical dislocation. However the post-operative rehabilitation protocols have varied greatly in the literature, with many having prolonged periods of limited motion and weight bearing. Purpose The purpose of this study was to describe a criterion-based early weight bearing protocol following hip arthroscopy and investigate functional outcomes in the subjects who were active duty military. Methods Active duty personnel undergoing hip arthroscopy for symptomatic femoroacetabular impingement were prospectively assessed in a controlled environment for the ability to incorporate early postoperative weight-bearing with the following criteria: no increased pain complaint with weight bearing and normalized gait pattern. Modified Harris Hip (HHS) and Hip Outcome score (HOS) were performed preoperatively and at six months post-op. Participants were progressed with a standard hip arthroscopy protocol. Hip flexion was limited to not exceed 90 degrees for the first three weeks post-op, with progression back to running beginning at three months. Final discharge was dependent upon the ability to run two miles at military specified pace and do a single leg broad jump within six inches of the contralateral leg without an increase in pain. Results Eleven participants met inclusion criteria over the study period. Crutch use was discontinued at an average of five days following surgery based on established weight bearing criteria. Only one participant required continued crutch use at 15 days. Participants’ functional outcome was improved postoperatively, as demonstrated by significant increases in HOS and HHS. At the six month follow up, eight of 11 participants were able to take and complete a full Army Physical Fitness Test. Conclusions Following completion of the early weight bearing rehabilitation protocol, 81% of participants were able to progress to full weight bearing by four days post-operative, with normalized pain-free gait patterns. Active duty personnel utilizing an early weight bearing protocol following hip arthroscopy demonstrated significant functional improvement at six months. Level of Evidence Level 4, Case-series PMID:29181261
Braun, Benedikt J; Bushuven, Eva; Hell, Rebecca; Veith, Nils T; Buschbaum, Jan; Holstein, Joerg H; Pohlemann, Tim
2016-02-01
Weight bearing after lower extremity fractures still remains a highly controversial issue. Even in ankle fractures, the most common lower extremity injury no standard aftercare protocol has been established. Average non weight bearing times range from 0 to 7 weeks, with standardised, radiological healing controls at fixed time intervals. Recent literature calls for patient-adapted aftercare protocols based on individual fracture and load scenarios. We show the clinical feasibility and first results of a new, insole embedded gait analysis tool for continuous monitoring of gait, load and activity. Ten patients were monitored with a new, independent gait analysis insole for up to 3 months postoperatively. Strict 20 kg partial weight bearing was ordered for 6 weeks. Overall activity, load spectrum, ground reaction forces, clinical scoring and general health data were recorded and correlated. Statistical analysis with power analysis, t-test and Spearman correlation was performed. Only one patient completely adhered to the set weight bearing limit. Average time in minutes over the limit was 374 min. Based on the parameters load, activity, gait time over 20 kg weight bearing and maximum ground reaction force high and low performers were defined after 3 weeks. Significant difference in time to painless full weight bearing between high and low performers was shown. Correlation analysis revealed a significant correlation between weight bearing and clinical scoring as well as pain (American Orthopaedic Foot and Ankle Society (AOFAS) Score rs=0.74; Olerud-Molander Score rs=0.93; VAS pain rs=-0.95). Early, continuous gait analysis is able to define aftercare performers with significant differences in time to full painless weight bearing where clinical or radiographic controls could not. Patient compliance to standardised weight bearing limits and protocols is low. Highly individual rehabilitation patterns were seen in all patients. Aftercare protocols should be adjusted to real-time patient conditions, rather than fixed intervals and limits. With a real-time measuring device high performers could be identified and influenced towards optimal healing conditions early, while low performers are recognised and missing healing influences could be corrected according to patient condition. Copyright © 2015 Elsevier Ltd. All rights reserved.
Di Miceli, Riccardo; Marambio, Carlotta Bustos; Zati, Alessandro; Monesi, Roberta; Benedetti, Maria Grazia
2017-12-01
Purpose The aim of this study was to assess the effect of knee bracing and timing of full weight bearing after anterior cruciate ligament reconstruction (ACLR) on functional outcomes at mid-term follow-up. Methods We performed a retrospective study on 41 patients with ACLR. Patients were divided in two groups: ACLR group, who received isolated ACL reconstruction and ACLR-OI group who received ACL reconstruction and adjunctive surgery. Information about age at surgery, bracing, full or progressive weight bearing permission after surgery were collected for the two groups. Subjective IKDC score was obtained at follow-up. Statistical analysis was performed to compare the two groups for IKDC score. Subgroup analysis was performed to assess the effect of postoperative regimen (knee bracing and weight bearing) on functional outcomes. Results The mean age of patients was 30.8 ± 10.6 years. Mean IKDC score was 87.4 ± 13.9. The mean follow-up was 3.5 ± 1.8 years. Twenty-two (53.7%) patients underwent ACLR only, while 19 (46.3%) also received other interventions, such as meniscal repair and/or collateral ligament suture. Analysis of overall data showed no differences between the groups for IKDC score. Patients in the ACLR group exhibited a significantly better IKDC score when no brace and full weight bearing after 4 weeks from surgery was prescribed in comparison with patients who worn a brace and had delayed full weight bearing. No differences were found with respect to the use of brace and postoperative weight bearing regimen in the ACLR-OI group. Conclusion Brace and delayed weight bearing after ACLR have a negative influence on long-term functional outcomes. Further research is required to explore possible differences in the patients operated on ACLR and other intervention with respect to the use of a brace and the timing of full weight bearing to identify optimal recovery strategies. Level of Evidence Level III, retrospective observational study.
Shaw, K Aaron; Jacobs, Jeremy M; Evanson, J Richard; Pniewski, Josh; Dickston, Michelle L; Mueller, Terry; Bojescul, John A
2017-10-01
Hip arthroscopy allows surgeons to address intra-articular pathology of the hip while avoiding more invasive open surgical dislocation. However the post-operative rehabilitation protocols have varied greatly in the literature, with many having prolonged periods of limited motion and weight bearing. The purpose of this study was to describe a criterion-based early weight bearing protocol following hip arthroscopy and investigate functional outcomes in the subjects who were active duty military. Active duty personnel undergoing hip arthroscopy for symptomatic femoroacetabular impingement were prospectively assessed in a controlled environment for the ability to incorporate early postoperative weight-bearing with the following criteria: no increased pain complaint with weight bearing and normalized gait pattern. Modified Harris Hip (HHS) and Hip Outcome score (HOS) were performed preoperatively and at six months post-op. Participants were progressed with a standard hip arthroscopy protocol. Hip flexion was limited to not exceed 90 degrees for the first three weeks post-op, with progression back to running beginning at three months. Final discharge was dependent upon the ability to run two miles at military specified pace and do a single leg broad jump within six inches of the contralateral leg without an increase in pain. Eleven participants met inclusion criteria over the study period. Crutch use was discontinued at an average of five days following surgery based on established weight bearing criteria. Only one participant required continued crutch use at 15 days. Participants' functional outcome was improved postoperatively, as demonstrated by significant increases in HOS and HHS. At the six month follow up, eight of 11 participants were able to take and complete a full Army Physical Fitness Test. Following completion of the early weight bearing rehabilitation protocol, 81% of participants were able to progress to full weight bearing by four days post-operative, with normalized pain-free gait patterns. Active duty personnel utilizing an early weight bearing protocol following hip arthroscopy demonstrated significant functional improvement at six months. Level 4, Case-series.
Tighilet, Brahim; Péricat, David; Frelat, Alais; Cazals, Yves; Rastoldo, Guillaume; Boyer, Florent; Dumas, Olivier
2017-01-01
Vestibular disorders, by inducing significant posturo-locomotor and cognitive disorders, can significantly impair the most basic tasks of everyday life. Their precise diagnosis is essential to implement appropriate therapeutic countermeasures. Monitoring their evolution is also very important to validate or, on the contrary, to adapt the undertaken therapeutic actions. To date, the diagnosis methods of posturo-locomotor impairments are restricted to examinations that most often lack sensitivity and precision. In the present work we studied the alterations of the dynamic weight distribution in a rodent model of sudden and complete unilateral vestibular loss. We used a system of force sensors connected to a data analysis system to quantify in real time and in an automated way the weight bearing of the animal on the ground. We show here that sudden, unilateral, complete and permanent loss of the vestibular inputs causes a severe alteration of the dynamic ground weight distribution of vestibulo lesioned rodents. Characteristics of alterations in the dynamic weight distribution vary over time and follow the sequence of appearance and disappearance of the various symptoms that compose the vestibular syndrome. This study reveals for the first time that dynamic weight bearing is a very sensitive parameter for evaluating posturo-locomotor function impairment. Associated with more classical vestibular examinations, this paradigm can considerably enrich the methods for assessing and monitoring vestibular disorders. Systematic application of this type of evaluation to the dizzy or unstable patient could improve the detection of vestibular deficits and allow predicting better their impact on posture and walk. Thus it could also allow a better follow-up of the therapeutic approaches for rehabilitating gait and balance. PMID:29112981
Tighilet, Brahim; Péricat, David; Frelat, Alais; Cazals, Yves; Rastoldo, Guillaume; Boyer, Florent; Dumas, Olivier; Chabbert, Christian
2017-01-01
Vestibular disorders, by inducing significant posturo-locomotor and cognitive disorders, can significantly impair the most basic tasks of everyday life. Their precise diagnosis is essential to implement appropriate therapeutic countermeasures. Monitoring their evolution is also very important to validate or, on the contrary, to adapt the undertaken therapeutic actions. To date, the diagnosis methods of posturo-locomotor impairments are restricted to examinations that most often lack sensitivity and precision. In the present work we studied the alterations of the dynamic weight distribution in a rodent model of sudden and complete unilateral vestibular loss. We used a system of force sensors connected to a data analysis system to quantify in real time and in an automated way the weight bearing of the animal on the ground. We show here that sudden, unilateral, complete and permanent loss of the vestibular inputs causes a severe alteration of the dynamic ground weight distribution of vestibulo lesioned rodents. Characteristics of alterations in the dynamic weight distribution vary over time and follow the sequence of appearance and disappearance of the various symptoms that compose the vestibular syndrome. This study reveals for the first time that dynamic weight bearing is a very sensitive parameter for evaluating posturo-locomotor function impairment. Associated with more classical vestibular examinations, this paradigm can considerably enrich the methods for assessing and monitoring vestibular disorders. Systematic application of this type of evaluation to the dizzy or unstable patient could improve the detection of vestibular deficits and allow predicting better their impact on posture and walk. Thus it could also allow a better follow-up of the therapeutic approaches for rehabilitating gait and balance.
Zhang, Tianlong; Gao, Jiazi; Fang, Juan; Gong, He
2018-03-01
This study aimed to explore the effects of additional weight bearing in combination with low-magnitude high-frequency vibration (LMHFV; 45 Hz, 0.3 g) on bone quality. One hundred twenty rats were randomly divided into ten groups; namely, sedentary (SED), additional weight bearing in which the rat wears a backpack whose weight is x% of the body weight (WBx; x = 5, 12, 19, 26), basic vibration (V), and additional weight bearing in combination with LMHFV in which the rat wears a backpack whose weight is x% of the body weight (Vx; x = 5, 12, 19, 26). The experiment was conducted for 12 weeks, 7 days per week, and 15 min per day. A three-point bending mechanical test, micro computed tomography, and a nanoindentation test were used. Serum samples were analyzed chemically. Failure load in V19 rats was significantly lower than that in SED rats (P < 0.05). Vx (x = 5, 12, 19, 26) rats showed poor microarchitectures. The content of tartrate-resistant acid phosphatase 5b was significantly higher in Vx (x = 5, 12, 19, 26) rats than that in SED rats (P < 0.05). V26 rats demonstrated comparatively better nanomechanical properties of materials than the other vibrational groups. Additional weight bearing in combination with LMHFV negatively affected the macromechanical properties and microarchitecture of bone. Heavy additional weight bearing, such as 26% of body weight, in combination with LMHFV was able to improve the nanomechanical properties of growing bone material compared with LMHFV. A combined mechanical stimulation was used, which may provide useful information to understand the mechanism of this mechanical stimulation on bone.
[Controlled weight bearing after osteosynthesis].
Perren, T; Matter, P
1993-01-01
Patient compliance with postoperative partial weight bearing can be a difficult management problem. The problem may be intentional or unintentional. There is no objective way to assess the amount of weight placed on the lower extremity by the patient. It is our clinical suspicion that patients place more weight than is desirable on the effected limb. There are few reports in the literature on this topic. One study has confirmed our suspicion of poor patient compliance with postoperative weight bearing. Our goal is to develop a system to accurately assess weight bearing and to improve this aspect of postoperative fracture care. Through an active feedback device we hope to improve patient education and understanding. We plan to study the clinical applications of using a pressure sensitive shoe insert device. Our ultimate goal is to improve upon the present device and to study the clinical application of there use.
Vonk, Jennifer; Johnson-Ulrich, Zoe
2014-09-01
One captive adult chimpanzee and 3 adult American black bears were presented with a series of natural category discrimination tasks on a touch-screen computer. This is the first explicit comparison of bear and primate abilities using identical tasks, and the first test of a social concept in a carnivore. The discriminations involved a social relationship category (mother/offspring) and a nonsocial category involving food items. The social category discrimination could be made using knowledge of the overarching mother/offspring concept, whereas the nonsocial category discriminations could be made only by using perceptual rules, such as "choose images that show larger and smaller items of the same type." The bears failed to show above-chance transfer on either the social or nonsocial discriminations, indicating that they did not use either the perceptual rule or knowledge of the overarching concept of mother/offspring to guide their choices in these tasks. However, at least 1 bear remembered previously reinforced stimuli when these stimuli were recombined, later. The chimpanzee showed transfer on a control task and did not consistently apply a perceptual rule to solve the nonsocial task, so it is possible that he eventually acquired the social concept. Further comparisons between species on identical tasks assessing social knowledge will help illuminate the selective pressures responsible for a range of social cognitive skills.
2012-08-21
FINAL DEMONSTRATION OF A WIRELESS DATA TASK SUPPORTED BY SLS ADVANCED DEVELOPMENT USED TO DEMONSTRATE REAL-TIME VIDEO OVER WIRELESS CONNECTIONS ALONG WITH DATA AND COMMANDS AS DEMONSTRATED VIA THE ROBOTIC ARMS. THE ARMS AND VIDEO CAMERAS WERE MOUNTED ON FREE FLOATING AIR-BEARING VEHICLES TO SIMULATE CONDITIONS IN SPACE. THEY WERE USED TO SHOW HOW A CHASE VEHICLE COULD MOVE UP TO AND CAPTURE A SATELLITE, SUCH AS THE FASTSAT MOCKUP DEMONSTRITING HOW ROBOTIC TECHNOLOGY AND SMALL SPACECRAFT COULD ASSIST WITH ORBITAL DEBRIS MITIGATION
2012-08-21
FINAL DEMONSTRATION OF A WIRELESS DATA TASK SUPPORTED BY SLS ADVANCED DEVELOPMENT USED TO DEMONSTRATE REAL-TIME VIDEO OVER WIRELESS CONNECTIONS ALONG WITH DATA AND COMMANDS AS DEMONSTRATED VIA THE ROBOTIC ARMS. THE ARMS AND VIDEO CAMERAS WERE MOUNTED ON FREE FLOATING AIR-BEARING VEHICLES TO SIMULATE CONDITIONS IN SPACE. THEY WERE USED TO SHOW HOW A CHASE VEHICLE COULD MOVE UP TO AND CAPTURE A SATELLITE, SUCH AS THE FASTSAT MOCKUP DEMONSTRITING HOW ROBOTIC TECHNOLOGY AND SMALL SPACECRAFT COULD ASSIST WITH ORBITAL DEBRIS MITIGATION
2012-08-21
FINAL DEMONSTRATION OF A WIRELESS DATA TASK SUPPORTED BY SLS ADVANCED DEVELOPMENT USED TO DEMONSTRATE REAL-TIME VIDEO OVER WIRELESS CONNECTIONS ALONG WITH DATA AND COMMANDS AS DEMONSTRATED VIA THE ROBOTIC ARMS. THE ARMS AND VIDEO CAMERAS WERE MOUNTED ON FREE FLOATING AIR-BEARING VEHICLES TO SIMULATE CONDITIONS IN SPACE. THEY WERE USED TO SHOW HOW A CHASE VEHICLE COULD MOVE UP TO AND CAPTURE A SATELLITE, SUCH AS THE FASTSAT MOCKUP DEMONSTRITING HOW ROBOTIC TECHNOLOGY AND SMALL SPACECRAFT COULD ASSIST WITH ORBITAL DEBRIS MITIGATION
Beumer, Annechien; Campo, Martin M; Niesing, Ruud; Day, Judd; Kleinrensink, Gert-Jan; Swierstra, Bart A
2005-01-01
We assessed syndesmotic set screw strength and fixation capacity during cyclical testing in a cadaver model simulating protected weight bearing. Sixteen fresh frozen legs with artificial syndesmotic injuries and a syndesmotic set screw made of stainless steel or titanium, inserted through three or four cortices, were axially loaded with 800 N for 225,000 cycles in a materials testing machine. The 225,000 cycles equals the number of paces taken by a person walking in a below knee plaster during 9 weeks. Syndesmotic fixation failure was defined as: bone fracture, screw fatigue failure, screw pullout, and/or excessive syndesmotic widening. None of the 14 out of 16 successfully tested legs or screws failed. No difference was found in fixation of the syndesmosis when stainless steel screws were compared to titanium screws through three or four cortices. Mean lateral displacement found after testing was 1.05 mm (S.D. = 0.42). This increase in tibiofibular width exceeds values described in literature for the intact syndesmosis loaded with body weight. Based on this laboratory study it is concluded that the syndesmotic set screw cannot prevent excessive syndesmotic widening when loaded with a load comparable with body weight. Therefore, we advise that patients with a syndesmotic set screw in situ should not bear weight.
Subchondral impaction fractures of the non-weight-bearing portion of the lateral femoral condyle.
Depasquale, Ruben; Fotiadou, Anastasia; Kumar, Dalavaye Suresh; Lalam, Radhesh; Tins, Bernhard; Tyrrell, Prudencia N M; Singh, Jaspreet; Cassar-Pullicino, Victor N
2013-02-01
To document the first report of intra-articular, non-weight-bearing, impaction fractures of the lateral femoral condyle. Institutional Review Board and Regional Ethics Committee approval for this study was obtained and patient informed consent deemed unnecessary. We prospectively documented all potential cases of non-weight-bearing posterior subchondral impaction fractures of the femoral condyles diagnosed on magnetic resonance imaging (MRI) of the knee performed at our institution between January 2006 and December 2011. The cases were reviewed and discussed by three experienced musculoskeletal radiologists and only cases satisfying pre-defined MRI criteria were included. Sixteen cases of intra-articular impaction fractures in a posterior, non-weight-bearing area of the lateral femoral condyle were diagnosed in patients with a mean age of 40. Eight were associated with recreational sports activities and 4 with repeated kneeling. There were no fractures documented in the non-weight-bearing aspect of the medial femoral condyles. Proposed underlying mechanisms for development of this type of fracture are presented. Awareness, along with a high level of suspicion, that non-specific knee pain, especially in patients involved in athletic activities, could be due to intra-articular impaction fractures of the non-weight-bearing posterior aspect of the lateral femoral condyle is essential and MRI is the mainstay of diagnosis.
Inoue, Hiroaki; Atsumi, Satoru; Ichimaru, Shohei; Fujiwara, Hiroyoshi; Kubo, Toshikazu
2014-01-01
Complications of patellar dislocation include osteochondral injury of the lateral femoral condyle and patella. Most cases of osteochondral injury occur in the anterior region, which is the non-weight-bearing portion of the lateral femoral condyle. We describe two patients with osteochondral injury of the weight-bearing surface of the lateral femoral condyle associated with lateral dislocation of the patella. The patients were 18- and 11-year-old females. Osteochondral injury occurred on the weight-bearing surface distal to the lateral femoral condyle. The presence of a free osteochondral fragment and osteochondral injury of the lateral femoral condyle was confirmed on MRI and reconstruction CT scan. Treatment consisted of osteochondral fragment fixation or microfracture, as well as patellar stabilization. Osteochondral injury was present in the weight-bearing portion of the lateral femoral condyle in both patients, suggesting that the injury was caused by friction between the patella and lateral femoral condyle when the patella was dislocated or reduced at about 90° flexion of the knee joint. These findings indicate that patellar dislocation may occur and osteochondral injury may extend to the weight-bearing portion of the femur even in deep flexion, when the patella is stabilized on the bones of the femoral groove. PMID:25506015
Chizewski, Michael G; Chiu, Loren Z F
2012-05-01
Joint angle is the relative rotation between two segments where one is a reference and assumed to be non-moving. However, rotation of the reference segment will influence the system's spatial orientation and joint angle. The purpose of this investigation was to determine the contribution of leg and calcaneal rotations to ankle rotation in a weight-bearing task. Forty-eight individuals performed partial squats recorded using a 3D motion capture system. Markers on the calcaneus and leg were used to model leg and calcaneal segment, and ankle joint rotations. Multiple linear regression was used to determine the contribution of leg and calcaneal segment rotations to ankle joint dorsiflexion. Regression models for left (R(2)=0.97) and right (R(2)=0.97) ankle dorsiflexion were significant. Sagittal plane leg rotation had a positive influence (left: β=1.411; right: β=1.418) while sagittal plane calcaneal rotation had a negative influence (left: β=-0.573; right: β=-0.650) on ankle dorsiflexion. Sagittal plane rotations of the leg and calcaneus were positively correlated (left: r=0.84, P<0.001; right: r=0.80, P<0.001). During a partial squat, the calcaneus rotates forward. Simultaneous forward calcaneal rotation with ankle dorsiflexion reduces total ankle dorsiflexion angle. Rear foot posture is reoriented during a partial squat, allowing greater leg rotation in the sagittal plane. Segment rotations may provide greater insight into movement mechanics that cannot be explained via joint rotations alone. Copyright © 2012 Elsevier B.V. All rights reserved.
Houben, I B; Raaben, M; Van Basten Batenburg, M; Blokhuis, T J
2018-04-09
The relation between timing of weight bearing after a fracture and the healing outcome is yet to be established, thereby limiting the implementation of a possibly beneficial effect for our patients. The current study was undertaken to determine the effect of timing of weight bearing after a surgically treated tibial shaft fracture. Surgically treated diaphyseal tibial fractures were retrospectively studied between 2007 and 2015. The timing of initial weight bearing (IWB) was analysed as a predictor for impaired healing in a multivariate regression. Totally, 166 diaphyseal tibial fractures were included, 86 cases with impaired healing and 80 with normal healing. The mean age was 38.7 years (range 16-89). The mean time until IWB was significantly shorter in the normal fracture healing group (2.6 vs 7.4 weeks, p < 0.001). Correlation analysis yielded four possible confounders: infection requiring surgical intervention, fracture type, fasciotomy and open fractures. Logistic regression identified IWB as an independent predictor for impaired healing with an odds ratio of 1.13 per week delay (95% CI 1.03-1.25). Delay in initial weight bearing is independently associated with impaired fracture healing in surgically treated tibial shaft fractures. Unlike other factors such as fracture type or soft tissue condition, early resumption of weight bearing can be influenced by the treating physician and this factor therefore has a direct clinical relevance. This study indicates that early resumption of weight bearing should be the treatment goal in fracture fixation. 3b.
Schröter, S; Ateschrang, A; Löwe, W; Nakayama, H; Stöckle, U; Ihle, C
2017-01-01
Open wedge high tibial osteotomy is a widespread treatment option in patients with varus malalignment and medial compartment osteoarthritis. There is no standardised protocol for post-operative rehabilitation available. The purpose of this study was to compare two post-operative rehabilitation protocols and to evaluate the clinical outcome of early full weight-bearing after open wedge HTO. One hundred and twenty consecutive patients with varus malalignment and medial compartment osteoarthritis received an open wedge HTO using an angular locking plate fixation between December 2008 and December 2011. All patients were assigned randomly into one of two groups with different post-operative rehabilitation protocols (11-day vs. 6-week 20-kg partial weight-bearing). Clinical outcome was evaluated using established instruments (Lequesne, Lysholm, HSS and IKDC scores) preoperatively, 6, 12 and 18 months post-operatively. Deformity analysis was performed preoperatively and during follow-up. All clinical scores showed a significant pre- to post-operative improvement. After 6 months, there was a higher improvement in the group of early full weight-bearing. The difference between preoperative and 6-month follow-up for the group with early full weight-bearing and for the group with 20-kg PWB for 6 weeks was 28 ± 26 and 18 ± 22, respectively, for the Lysholm score and -5.0 ± 5.1 and -3.0 ± 3.6, respectively, for the Lequesne score. Early full weight-bearing (11-day 20-kg partial weight-bearing) after open wedge HTO without bone graft leads to earlier improvement of the clinical results and can be recommended for post-operative rehabilitation after open wedge HTO and fixation with an angular locking plate. Therapeutic study, Level I.
Influences of chemical sympathectomy and simulated weightlessness on male and female rats
NASA Technical Reports Server (NTRS)
Woodman, Christopher R.; Stump, Craig S.; Stump, Jane A.; Sebastian, Lisa A.; Rahman, Z.; Tipton, Charles M.
1991-01-01
Consideration is given to a study aimed at determining whether the sympathetic nervous system is associated with the changes in maximum oxygen consumption (VO2max), run time, and mechanical efficiency observed during simulated weightlessness in male and female rats. Female and male rats were compared for food consumption, body mass, and body composition in conditions of simulated weightlessness to provide an insight into how these parameters may influence aerobic capacity and exercise performance. It is concluded that chemical sympathectomy and/or a weight-bearing stimulus will attenuate the loss in VO2max associated with simulated weightlessness in rats despite similar changes in body mass and composition. It is noted that the mechanisms remain unclear at this time.
Demonstration, Testing and Qualification of a High Temperature, High Speed Magnetic Thrust Bearing
NASA Technical Reports Server (NTRS)
DeWitt, Kenneth
2005-01-01
The gas turbine industry has a continued interest in improving engine performance and reducing net operating and maintenance costs. These goals are being realized because of advancements in aeroelasticity, materials, and computational tools such as CFD and engine simulations. These advancements aid in increasing engine thrust-to-weight ratios, specific fuel consumption, pressure ratios, and overall reliability through higher speed, higher temperature, and more efficient engine operation. Currently, rolling element bearing and squeeze film dampers are used to support rotors in gas turbine engines. Present ball bearing configurations are limited in speed (<2 million DN) and temperature (<5OO F) and require both cooling air and an elaborate lubrication system. Also, ball bearings require extensive preventative maintenance in order to assure their safe operation. Since these bearings are at their operational limits, new technologies must be found in order to take advantage of other advances. Magnetic bearings are well suited to operate at extreme temperatures and higher rotational speeds and are a promising solution to the problems that conventional rolling element bearings present. Magnetic bearing technology is being developed worldwide and is considered an enabling technology for new engine designs. Using magnetic bearings, turbine and compressor spools can be radically redesigned to be significantly larger and stiffer with better damping and higher rotational speeds. These advances, a direct result of magnetic bearing technology, will allow significant increases in engine power and efficiency. Also, magnetic bearings allow for real-time, in-situ health monitoring of the system, lower maintenance costs and down time.
Muhit, A; Zbijewski, W; Stayman, J; Thawait, G; Yorkston, J; Foos, D; Packard, N; Yang, D; Senn, R; Carrino, J; Siewerdsen, J
2012-06-01
To assess the diagnostic performance of a prototype cone-beam CT (CBCT) scanner developed for musculoskeletal extremity imaging. Studies involved controlled observer studies conducted subsequent to rigorous technical assessment as well as patient images from the first clinical trial in imaging the hand and knee. Performance assessment included: 1.) rigorous technical assessment; 2.) controlled observer studies using CBCT images of cadaveric specimens; and 3.) first clinical images. Technical assessment included measurement of spatial resolution (MTF), constrast, and noise (SDNR) versus kVp and dose using standard CT phantoms. Diagnostic performance in comparison to multi- detector CT (MDCT) was assessed in controlled observer studies involving 12 cadaveric hands and knees scanned with and without abnormality (fracture). Observer studies involved five radiologists rating pertinent diagnostics tasks in 9-point preference and 10-point diagnostic satisfaction scales. Finally, the first clinical images from an ongoing pilot study were assessed in terms of diagnostic utility in disease assessment and overall workflow in patient setup. Quantitative assessment demonstrated sub-mm spatial resolution (MTF exceeding 10% out to 15-20 cm-1) and SDNR sufficient for relevant soft-tissue visualization tasks at dose <10 mGy. Observer studies confirmed optimal acquisition techniques and demonstrated superior utility of combined soft-tissue visualization and isotropic spatial resolution in diagnostic tasks. Images from the patient trial demonstrate exquisite contrast and detail and the ability to detect tissue impingement in weight-bearing exams. The prototype CBCT scanner provides isotropic spatial resolution superior to standard-protocol MDCT with soft-tissue visibility sufficient for a broad range of diagnostic tasks in musculoskeletal radiology. Dosimetry and workflow were advantageous in comparison to whole-body MDCT. Multi-mode and weight-bearing capabilities add valuable functionality. An ongoing clinical study further assesses diagnostic utility and defines the role of such technology in the diagnostic arsenal. - Research Grant, Carestream Health - Research Grant, National Institutes of Health 2R01-CA-112163. © 2012 American Association of Physicists in Medicine.
Reproducibilty of partial weight bearing.
Malviya, A; Richards, J; Jones, Richard K; Udwadia, A; Doyle, J
2005-04-01
To find out whether partial weight bearing can be reproduced and retained. In vivo experiment in normal subjects. Training for partial weight bearing (25% of body weight) using bathroom scales. Reproducibility on force platform immediately after training and after 60 min. Twelve subjects were asked to reproduce 25% of their body weight through either the dominant or non-dominant limb on force platform after three practice attempts on bathroom scales with concurrent visual feedback. No feedback was provided after the measurements on force plate. The process was repeated after 1h without any practice sessions in the interim period to find out if the weight practised could be retained. The mean 0-min reading was found to be 25.9% of body weight while the mean 60-min reading was found to be 24.4%. The p-value for the difference between the two means was found to be 0.3841. This study indicates that partial weight bearing instructions can be quantified and graded. Simple bathroom scales are sufficient to educate the patients and this can be practised at home after an initial period of supervision.
The Impact of Human-Automation Collaboration in Decentralized Multiple Unmanned Vehicle Control
2011-01-01
based decentralized auctions for robust task allocation ,[ IEEE Trans. Robot., vol. 25, no. 4, pp...operators can aid such systems by bringing their knowledge- based reasoning and experience to bear. Given a decentralized task planner and a goal- based ...experience to bear. Given a decentralized task planner and a goal- based operator interface for a network of unmanned vehicles in a search, track,
Seki, Eiko; Matsushita, Isao; Sugiyama, Eiji; Taki, Hirohumi; Shinoda, Koichiro; Hounoki, Hiroyuki; Motomura, Hiraku; Kimura, Tomoatsu
2009-04-01
The aim of the present study was to assess the influence of tumor necrosis factor (TNF)-blocking therapies on weight-bearing joints in patients with rheumatoid arthritis. Changes in clinical variables and radiological findings in 213 weight-bearing joints (69 hip joints, 63 knee joints, and 81 ankle joints) of 42 consecutive patients were investigated at baseline and at 1 year of TNF-blocking therapies. Structural damage to the weight-bearing joints was assessed using the Larsen scoring method. Detailed comparisons of the sizes and locations of erosions were performed for each set of radiographs of the respective joints. Assessment of radiographs of the 213 weight-bearing joints indicated progression of the Larsen grade in eight joints. Another five joints without Larsen grade progression showed apparent radiographic progression of joint damage based on increases in bony erosions. Overall, 13 joints (6%) of eight patients (19%) showed progression of joint damage after 1 year of TNF-blocking therapies. Analysis of each baseline grade indicated that radiographic progression of joint damage was inhibited in most grade 0-II joints. On the other hand, all hip and knee joints with pre-existing damage of grade III/IV showed apparent progression even in patients with good response. The results further suggested that radiographic progression may occur in less damaged joints when the patients were non-responders to the therapy. Among the weight-bearing joints, ankle joints showed different radiographic behavior and four ankle joints displayed improvement of radiographic damage. Early initiation of anti-TNF therapy should be necessary especially when the patients are starting to show early structural damage in weight-bearing joints.
Xu, Bowen; Zhang, Qingsong; An, Siqi; Pei, Baorui; Wu, Xiaobo
2017-08-01
To establish the model of compression fracture of acetabular dome, and to measure the contact characteristics of acetabular weight-bearing area of acetabulum after 3 kinds of internal fixation. Sixteen fresh adult half pelvis specimens were randomly divided into 4 groups, 4 specimens each group. Group D was the complete acetabulum (control group), and the remaining 3 groups were prepared acetabular dome compression fracture model. The fractures were fixed with reconstruction plate in group A, antegrade raft screws in group B, and retrograde raft screws in group C. The pressure sensitive films were attached to the femoral head, and the axial compression test was carried out on the inverted single leg standing position. The weight-bearing area, average stress, and peak stress were measured in each group. Under the loading of 500 N, the acetabular weight-bearing area was significantly higher in group D than in other 3 groups ( P <0.05), and the average stress and peak stress were significantly lower than in other 3 groups ( P <0.05). The acetabular weight-bearing area were significantly higher in group B and group C than in group A, and the average stress and peak stress were significantly lower than in group A ( P <0.05). There was no significant difference in the above indexes between group B and group C ( P >0.05). For the compression fracture of the acetabular dome, the contact characteristics of the weight-bearing area can not restore to the normal level, even if the anatomical reduction and rigid internal fixation were performed; compared with the reconstruction plate fixation, antegrade and retrograde raft screws fixations can increase the weight-bearing area, reduce the average stress and peak stress, and reduce the incidence of traumatic arthritis.
Lardelli, Patrizia; Frech-Dörfler, Martina; Holland-Cunz, Stefan; Mayr, Johannes
2016-01-01
Abstract Stabilization of diaphyseal long-bone fractures using elastic stable intramedullary nails (ESIN) in children promises early mobilization and rapid resumption of full weight bearing. We evaluated the duration of postoperative functional rehabilitation after ESIN, measured by the time from stabilization until first partial weight bearing, full weight bearing, and resumption of school sports. Fifty children with unstable, displaced fractures of the femur or lower leg treated with ESIN between 2002 and 2012 were included in this retrospective analysis. We classified fractures according to the pediatric comprehensive classification of fractures (PCCF). Thirty-five children sustained a femur fracture, and 15 children had a fracture of the lower leg or tibia. The surgeons in charge applied an additional plaster cast in 7 of 15 children who suffered a lower leg fracture. The postoperative time interval until full weight bearing in the group of children who had suffered transverse or short oblique femur fractures was significantly shorter (median: 4.4 weeks; range: 0.1–9.1 weeks) than that in the group who had sustained more complex fracture patterns (median: 6.8 weeks; range: 2.9–13.9 weeks; P = 0.04). Similarly, transverse and short oblique lower leg and tibia fractures required less time until full weight bearing (median: 4.1 weeks; range 2.7–6.0 weeks) than complex lower leg fractures (median: 6.1 weeks; range: 1.3–12.9 weeks; P = 0.04). ESIN proved fairly effective in restoring full weight bearing in transverse or short oblique fractures of the lower extremities but was less effective in complex fractures. PMID:26986106
Lardelli, Patrizia; Frech-Dörfler, Martina; Holland-Cunz, Stefan; Mayr, Johannes
2016-03-01
Stabilization of diaphyseal long-bone fractures using elastic stable intramedullary nails (ESIN) in children promises early mobilization and rapid resumption of full weight bearing. We evaluated the duration of postoperative functional rehabilitation after ESIN, measured by the time from stabilization until first partial weight bearing, full weight bearing, and resumption of school sports. Fifty children with unstable, displaced fractures of the femur or lower leg treated with ESIN between 2002 and 2012 were included in this retrospective analysis. We classified fractures according to the pediatric comprehensive classification of fractures (PCCF). Thirty-five children sustained a femur fracture, and 15 children had a fracture of the lower leg or tibia. The surgeons in charge applied an additional plaster cast in 7 of 15 children who suffered a lower leg fracture. The postoperative time interval until full weight bearing in the group of children who had suffered transverse or short oblique femur fractures was significantly shorter (median: 4.4 weeks; range: 0.1-9.1 weeks) than that in the group who had sustained more complex fracture patterns (median: 6.8 weeks; range: 2.9-13.9 weeks; P = 0.04). Similarly, transverse and short oblique lower leg and tibia fractures required less time until full weight bearing (median: 4.1 weeks; range 2.7-6.0 weeks) than complex lower leg fractures (median: 6.1 weeks; range: 1.3-12.9 weeks; P = 0.04). ESIN proved fairly effective in restoring full weight bearing in transverse or short oblique fractures of the lower extremities but was less effective in complex fractures.
Development of smart bridge bearings system : a feasibility study : final report.
DOT National Transportation Integrated Search
2005-12-01
The goal of this project has been achieved through three tasks. The main goal of Task I has been : to identify appropriate sensors that have potential for bridge bearings applications. This has been : achieved through the following subtasks and has b...
Schildhauer, T A; Josten, Ch; Muhr, G
2006-01-01
Presentation of a new triangular osteosynthesis technique that permits early weight-bearing in vertically unstable sacral fractures. : Retrospective evaluation of a consecutive series. Level I trauma center. Thirty-four patients, twenty-eight of whom were poly-traumatized, all with vertically unstable sacral fractures. This group included eight women and twenty-six men, with a mean age of thirty-five years. Average time between trauma and definite operation was thirteen days (range 0 to 28 days). All patients underwent triangular osteosynthesis using a combination of a vertical vertebro-pelvic distraction osteosynthesis (pedicle screw system) and a transverse fixation of the sacrum fracture with either iliosacral screws or trans-sacral plating. Immediate postoperative weight-bearing was permitted postoperatively. Nineteen patients were treated with early progressive weight-bearing and advanced to full weight-bearing, on average, after twenty-three days (range 8 to 70 days). Three of the thirty-four patients (9 percent) experienced loosening of hardware, including two patients (6 percent) who required secondary intervention because of loss of the original reduction. Further complications included one pulmonary embolism (3 percent), one iatrogenic nerve lesion (3 percent), one wound necrosis (3 percent), and two local infections (6 percent). Triangular osteosynthesis is a demanding procedure that can be performed on vertically unstable sacral fractures to allow early progressive weight-bearing with an acceptable complication rate.
NASA Technical Reports Server (NTRS)
Block, Jon E.; Friedlander, Anne L.; Brooks, George A.; Steiger, Peter; Stubbs, Harrison A.
1989-01-01
The effect of weight bearing activity on the bone density was investigated in athletes by comparing the measures of bone density of athletes engaged in weight-training programs with those of polo players and nonexercising subjects. All subjects had measurements of spinal trabecular and integral bone density by quantitative tomography, as well as determinations of hip bone density by dual photon absorptiometry. Results confirmed previous findings by Block et al. (1987) of significantly greater bone density among highly trained athletes compared with nonexercising subjects of similar age. Results also indicated that athletes engaged in non-weight-bearing forms of rigorous exercise had greater levels of bone density. However, as the participants in this study were exceptional athletes, engaged in a strenuous sport with both aerobic and heavy resistance components, a confirmation of these data is needed, using larger samples of individuals.
Normal axial alignment of the lower extremity and load-bearing distribution at the knee.
Hsu, R W; Himeno, S; Coventry, M B; Chao, E Y
1990-06-01
Based on a series of 120 normal subjects of different gender and age, the geometry of the knee joint was analyzed using a full-length weight-bearing roentgenogram of the lower extremity. A special computer program based on the theory of a rigid body spring model was applied to calculate the important anatomic and biomechanical factors of the knee joint. The tibiofemoral mechanical angle was 1.2 degrees varus. Hence, it is difficult to rationalize the 3 degree varus placement of the tibial component in total knee arthroplasty suggested by some authors. The distal femoral anatomic valgus (measured from the lower one-half of the femur) was 4.2 degrees in reference to its mechanical axis. This angle became 4.9 degrees when the full-length femoral anatomic axis was used. When simulating a one-legged weight-bearing stance by shifting the upper-body gravity closer to the knee joint, 75% of the knee joint load passed through the medial tibial plateau. The knee joint-line obliquity was more varus in male subjects. The female subjects had a higher peak joint pressure and a greater patello-tibial Q angle. Age had little effect on the factors relating to axial alignment of the lower extremity and load transmission through the knee joint.
Evacuated load-bearing high performance insulation study
NASA Technical Reports Server (NTRS)
Parmley, R. T.; Cunnington, G. R.
1977-01-01
A light weight, vacuum jacketed, load bearing cryogenic insulation system was developed and tested on a 1.17-m (46-in.) spherical test tank. The vacuum jacket consists of 0.08 mm (0.003 in.) thick 321 stainless steel formed into a wedge design that allows elastic jacket movements as the tank shrinks (cools) or expands (warms up or is pressurized). Hollow glass spheres, approximately 80 micrometers in diameter with a bulk density of 0.069 g/cc (4.3 lb cubic foot), provide the insulating qualities and one atmosphere load bearing capability required. The design, fabrication, and test effort developed the manufacturing methods and engineering data needed to scale the system to other tank sizes, shapes, and applications. The program demonstrated that thin wall jackets can be formed and welded to maintain the required vacuum level of .013 Pa yet flex elastically for multiple reuses. No significant shifting or breakage of the microspheres occurred after 13 simulated Space Tug flight cycles on the test tank and a hundred 1 atmosphere load cycles in a flat plate calorimeter. The test data were then scaled to the Space Tug LO2 and LH2 tanks, and weight, thermal performance, payload performance, and costs were compared with a helium purged multilayer insulation system.
Overview of Lightweight Structures for Rotorcraft Engines and Drivetrains
NASA Technical Reports Server (NTRS)
Roberts, Gary D.
2011-01-01
This is an overview presentation of research being performed in the Advanced Materials Task within the NASA Subsonic Rotary Wing Project. This research is focused on technology areas that address both national goals and project goals for advanced rotorcraft. Specific technology areas discussed are: (1) high temperature materials for advanced turbines in turboshaft engines; (2) polymer matrix composites for lightweight drive system components; (3) lightweight structure approaches for noise and vibration control; and (4) an advanced metal alloy for lighter weight bearings and more reliable mechanical components. An overview of the technology in each area is discussed, and recent accomplishments are presented.
Pfeil, Thomas; Potjans, Tobias C; Schrader, Sven; Potjans, Wiebke; Schemmel, Johannes; Diesmann, Markus; Meier, Karlheinz
2012-01-01
Large-scale neuromorphic hardware systems typically bear the trade-off between detail level and required chip resources. Especially when implementing spike-timing dependent plasticity, reduction in resources leads to limitations as compared to floating point precision. By design, a natural modification that saves resources would be reducing synaptic weight resolution. In this study, we give an estimate for the impact of synaptic weight discretization on different levels, ranging from random walks of individual weights to computer simulations of spiking neural networks. The FACETS wafer-scale hardware system offers a 4-bit resolution of synaptic weights, which is shown to be sufficient within the scope of our network benchmark. Our findings indicate that increasing the resolution may not even be useful in light of further restrictions of customized mixed-signal synapses. In addition, variations due to production imperfections are investigated and shown to be uncritical in the context of the presented study. Our results represent a general framework for setting up and configuring hardware-constrained synapses. We suggest how weight discretization could be considered for other backends dedicated to large-scale simulations. Thus, our proposition of a good hardware verification practice may rise synergy effects between hardware developers and neuroscientists.
Pfeil, Thomas; Potjans, Tobias C.; Schrader, Sven; Potjans, Wiebke; Schemmel, Johannes; Diesmann, Markus; Meier, Karlheinz
2012-01-01
Large-scale neuromorphic hardware systems typically bear the trade-off between detail level and required chip resources. Especially when implementing spike-timing dependent plasticity, reduction in resources leads to limitations as compared to floating point precision. By design, a natural modification that saves resources would be reducing synaptic weight resolution. In this study, we give an estimate for the impact of synaptic weight discretization on different levels, ranging from random walks of individual weights to computer simulations of spiking neural networks. The FACETS wafer-scale hardware system offers a 4-bit resolution of synaptic weights, which is shown to be sufficient within the scope of our network benchmark. Our findings indicate that increasing the resolution may not even be useful in light of further restrictions of customized mixed-signal synapses. In addition, variations due to production imperfections are investigated and shown to be uncritical in the context of the presented study. Our results represent a general framework for setting up and configuring hardware-constrained synapses. We suggest how weight discretization could be considered for other backends dedicated to large-scale simulations. Thus, our proposition of a good hardware verification practice may rise synergy effects between hardware developers and neuroscientists. PMID:22822388
Bower, Kelly J.; McGinley, Jennifer L.; Miller, Kimberly J.; Clark, Ross A.
2014-01-01
Background and Objectives The Wii Balance Board (WBB) is a globally accessible device that shows promise as a clinically useful balance assessment tool. Although the WBB has been found to be comparable to a laboratory-grade force platform for obtaining centre of pressure data, it has not been comprehensively studied in clinical populations. The aim of this study was to investigate the measurement properties of tests utilising the WBB in people after stroke. Methods Thirty individuals who were more than three months post-stroke and able to stand unsupported were recruited from a single outpatient rehabilitation facility. Participants performed standardised assessments incorporating the WBB and customised software (static stance with eyes open and closed, static weight-bearing asymmetry, dynamic mediolateral weight shifting and dynamic sit-to-stand) in addition to commonly employed clinical tests (10 Metre Walk Test, Timed Up and Go, Step Test and Functional Reach) on two testing occasions one week apart. Test-retest reliability and construct validity of the WBB tests were investigated. Results All WBB-based outcomes were found to be highly reliable between testing occasions (ICC = 0.82 to 0.98). Correlations were poor to moderate between WBB variables and clinical tests, with the strongest associations observed between task-related activities, such as WBB mediolateral weight shifting and the Step Test. Conclusions The WBB, used with customised software, is a reliable and potentially useful tool for the assessment of balance and weight-bearing asymmetry following stroke. Future research is recommended to further investigate validity and responsiveness. PMID:25541939
Bower, Kelly J; McGinley, Jennifer L; Miller, Kimberly J; Clark, Ross A
2014-01-01
The Wii Balance Board (WBB) is a globally accessible device that shows promise as a clinically useful balance assessment tool. Although the WBB has been found to be comparable to a laboratory-grade force platform for obtaining centre of pressure data, it has not been comprehensively studied in clinical populations. The aim of this study was to investigate the measurement properties of tests utilising the WBB in people after stroke. Thirty individuals who were more than three months post-stroke and able to stand unsupported were recruited from a single outpatient rehabilitation facility. Participants performed standardised assessments incorporating the WBB and customised software (static stance with eyes open and closed, static weight-bearing asymmetry, dynamic mediolateral weight shifting and dynamic sit-to-stand) in addition to commonly employed clinical tests (10 Metre Walk Test, Timed Up and Go, Step Test and Functional Reach) on two testing occasions one week apart. Test-retest reliability and construct validity of the WBB tests were investigated. All WBB-based outcomes were found to be highly reliable between testing occasions (ICC = 0.82 to 0.98). Correlations were poor to moderate between WBB variables and clinical tests, with the strongest associations observed between task-related activities, such as WBB mediolateral weight shifting and the Step Test. The WBB, used with customised software, is a reliable and potentially useful tool for the assessment of balance and weight-bearing asymmetry following stroke. Future research is recommended to further investigate validity and responsiveness.
Nonlinear Control of Large Disturbances in Magnetic Bearing Systems
NASA Technical Reports Server (NTRS)
Jiang, Yuhong; Zmood, R. B.
1996-01-01
In this paper, the nonlinear operation of magnetic bearing control methods is reviewed. For large disturbances, the effects of displacement constraints and power amplifier current and di/dt limits on bearing control system performance are analyzed. The operation of magnetic bearings exhibiting self-excited large scale oscillations have been studied both experimentally and by simulation. The simulation of the bearing system has been extended to include the effects of eddy currents in the actuators, so as to improve the accuracy of the simulation results. The results of these experiments and simulations are compared, and some useful conclusions are drawn for improving bearing system robustness.
Marzo, John M; Kluczynski, Melissa A; Clyde, Corey; Anders, Mark J; Mutty, Christopher E; Ritter, Christopher A
2017-12-01
For AO 44-B2 ankle fractures of uncertain stability, the current diagnostic standard is to obtain a gravity stress radiograph, but some have advocated for the use of weight-bearing radiographs. The primary aim was to compare measures of medial clear space (MCS) on weight-bearing cone beam computed tomography (CBCT) scans versus gravity stress radiographs for determining the state of stability of ankle fractures classified as AO SER 44-B2 or Weber B. The secondary aim was to evaluate the details offered by CBCT scans with respect to other findings that may be relevant to patient care. Nine patients were enrolled in this cross-sectional study between April 2016 and February 2017 if they had an AO SER 44-B2 fracture of uncertain stability, had a gravity stress radiograph, and were able to undergo CT scan within seven days. The width of the MCS was measured at the level of the talar dome on all radiographs and at the mid coronal slice on CT. Wilcoxon signed-ranks tests were used to compare MCS between initial radiographs, gravity stress radiographs and weight-bearing CBCT scans. MCS on weight-bearing CBCT scan (1.41±0.41 mm) was significantly less than standard radiographs (3.28±1.63 mm, P=0.004) and gravity stress radiographs (5.82±1.93 mm, P=0.02). There was no statistically significant difference in MCS measured on standard radiographs versus gravity stress radiographs (P=0.11). Detailed review of the multiplanar CT images revealed less than perfect anatomical reduction of the fractures, with residual fibular shortening, posterior displacement, and fracture fragments in the incisura as typical findings. Similar to weight-bearing radiographs, weight-bearing CBCT scan can predict stability of AO 44-B2 ankle fractures by showing restoration of the MCS, and might be used to indicate patients for non-operative treatment. None of the fractures imaged in this study were perfectly reduced however, and further clinical research is necessary to determine if any of the detailed weight-bearing CBCT findings are related to patient outcomes.
Automated assessment of pain in rats using a voluntarily accessed static weight-bearing test.
Kim, Hung Tae; Uchimoto, Kazuhiro; Duellman, Tyler; Yang, Jay
2015-11-01
The weight-bearing test is one method to assess pain in rodent animal models; however, the acceptance of this convenient method is limited by the low throughput data acquisition and necessity of confining the rodents to a small chamber. We developed novel data acquisition hardware and software, data analysis software, and a conditioning protocol for an automated high throughput static weight-bearing assessment of pain. With this device, the rats voluntarily enter the weighing chamber, precluding the necessity to restrain the animals and thereby removing the potential stress-induced confounds as well as operator selection bias during data collection. We name this device the Voluntarily Accessed Static Incapacitance Chamber (VASIC). Control rats subjected to the VASIC device provided hundreds of weight-bearing data points in a single behavioral assay. Chronic constriction injury (CCI) surgery and paw pad injection of complete Freund's adjuvant (CFA) or carrageenan in rats generated hundreds of weight-bearing data during a 30 minute recording session. Rats subjected to CCI, CFA, or carrageenan demonstrated the expected bias in weight distribution favoring the un-operated leg, and the analgesic effect of i.p. morphine was demonstrated. In comparison with existing methods, brief water restriction encouraged the rats to enter the weighing chamber to access water, and an infrared detector confirmed the rat position with feet properly positioned on the footplates, triggering data collection. This allowed hands-off measurement of weight distribution data reducing operator selection bias. The VASIC device should enhance the hands-free parallel collection of unbiased weight-bearing data in a high throughput manner, allowing further testing of this behavioral measure as an effective assessment of pain in rodents. Copyright © 2015. Published by Elsevier Inc.
Automated assessment of pain in rats using a voluntarily accessed static weight-bearing test
Kim, Hung Tae; Uchimoto, Kazuhiro; Duellman, Tyler; Yang, Jay
2015-01-01
The weight-bearing test is one method to assess pain in rodent animal models; however, the acceptance of this convenient method is limited by the low throughput data acquisition and necessity of confining the rodents to a small chamber. New methods We developed novel data acquisition hardware and software, data analysis software, and a conditioning protocol for an automated high throughput static weight-bearing assessment of pain. With this device, the rats voluntarily enter the weighing chamber, precluding the necessity to restrain the animals and thereby removing the potential stress-induced confounds as well as operator selection bias during data collection. We name this device the Voluntarily Accessed Static Incapacitance Chamber (VASIC). Results Control rats subjected to the VASIC device provided hundreds of weight-bearing data points in a single behavioral assay. Chronic constriction injury (CCI) surgery and paw pad injection of complete Freund's adjuvant (CFA) or carrageenan in rats generated hundreds of weight-bearing data during a 30 minute recording session. Rats subjected to CCI, CFA, or carrageenan demonstrated the expected bias in weight distribution favoring the un-operated leg, and the analgesic effect of i.p. morphine was demonstrated. In comparison with existing methods, brief water restriction encouraged the rats to enter the weighing chamber to access water, and an infrared detector confirmed the rat position with feet properly positioned on the footplates, triggering data collection. This allowed hands-off measurement of weight distribution data reducing operator selection bias. Conclusion The VASIC device should enhance the hands-free parallel collection of unbiased weight-bearing data in a high throughput manner, allowing further testing of this behavioral measure as an effective assessment of pain in rodents. PMID:26143745
Treatment of periprosthetic femoral fractures of the knee.
Ehlinger, Matthieu; Adam, Philippe; Abane, Lamine; Rahme, Michel; Moor, Beat Kaspar; Arlettaz, Yvan; Bonnomet, François
2011-09-01
We report a continuous series of periprosthetic femoral fractures after knee arthroplasty treated with a locking plate. We hypothesize that minimally invasive surgery and immediate weight-bearing improve functional recovery. From June 2002 to December 2008, 15 patients with 16 fractures were treated. Median age was 81 years. The autonomy level according to the mobility score of Parker and Palmer showed a median of 5 (0-9). Osteosynthesis was performed mainly through a minimally invasive approach using a locking compression plate. The rehabilitation protocol consisted of immediate mobilization and, whenever possible, immediate unrestricted weight-bearing. Five patients died during follow-up, more than 1 year after osteosynthesis. Their results were included. Autonomy and mobility were preserved with a median postoperative score of 4 (0-9) according to Parker and Palmer. The consolidation rate was 93.8%, which was obtained within 10 weeks. There were no mechanical or infectious complications. Fourteen cases were treated with minimally invasive surgery without fracture exposition; the remaining 2 required a slightly more extended approach. Full weight-bearing occurred 10 times; 20-kg partial weight-bearing was advised twice; and on 4 occasions, no weight-bearing was allowed for 6 weeks. Osteosynthesis with a minimally invasive bridge-plating technique is effective in the treatment of periprosthetic, distal femoral fractures without component loosening. Immediate full weight-bearing is possible if certain rules are respected. The surgical management presented herein is beneficial for these challenging fractures, and it may help reduce the complication rate and improve functional outcome.
Space Shuttle Main Engine (SSME) LOX turbopump pump-end bearing analysis
NASA Technical Reports Server (NTRS)
1986-01-01
A simulation of the shaft/bearing system of the Space Shuttle Main Engine Liquid Oxygen turbopump was developed. The simulation model allows the thermal and mechanical characteristics to interact as a realistic simulation of the bearing operating characteristics. The model accounts for single and two phase coolant conditions, and includes the heat generation from bearing friction and fluid stirring. Using the simulation model, parametric analyses were performed on the 45 mm pump-end bearings to investigate the sensitivity of bearing characteristics to contact friction, axial preload, coolant flow rate, coolant inlet temperature and quality, heat transfer coefficients, outer race clearance and misalignment, and the effects of thermally isolating the outer race from the isolator.
Smith, Jo Armour; Popovich, John M; Kulig, Kornelia
2014-07-01
Cross-sectional laboratory study. To compare peak lower-limb, pelvis, and trunk kinematics and interjoint and intersegmental coordination in women with strong and weak hip muscle performance. Persons with lower extremity musculoskeletal disorders often demonstrate a combination of weak hip musculature and altered kinematics during weight-bearing dynamic tasks. However, the association between hip strength and kinematics independent of pathology or pain is unclear. Peak hip extensor and abductor torques were measured in 150 healthy young women. Of these, 10 fit the criteria for the strong group and 9 for the weak group, representing those with the strongest and weakest hip musculature, respectively, of the 150 screened individuals. Kinematics of the hip, knee, pelvis, and trunk were measured during the stance phases of walking and rate-controlled hopping. Hip/knee and pelvis/trunk coordination were calculated using the vector coding technique. There were no group differences in peak hip, knee, or pelvis kinematics. Participants in the weak group demonstrated greater trunk lateral bend toward the stance limb during hopping (P = .002, effect size [d] = 1.88). In the transverse plane, those in the weak group utilized less inphase coordination between the hip and the knee during walking (P = .036, d = 1.45) and more antiphase coordination between the hip and knee during hopping (P = .03, d = 1.47). In the absence of pain or pathology, poor hip muscle performance does not affect peak hip or knee joint kinematics in young women, but is associated with significantly different lower-limb and trunk/pelvis coordination during weight-bearing dynamic tasks. J Orthop Sports Phys Ther 2014;44(7):525-531. Epub 10 May 2014. doi:10.2519/jospt.2014.5028.
Foot Loading Characteristics of Different Graduations of Partial Weight Bearing
ERIC Educational Resources Information Center
Gusinde, Johannes; Pauser, Johannes; Swoboda, Bernd; Gelse, Kolja; Carl, Hans-Dieter
2011-01-01
Limited weight bearing of the lower extremity is a commonly applied procedure in orthopaedic rehabilitation after reconstructive forefoot surgery, trauma surgery and joint replacement. The most frequent limitations are given as percentage of body weight (BW) and represent 10 or 50% BW. The extent of foot loading under these graduations of partial…
Effects of insulin and exercise on rat hindlimb muscles after simulated microgravity
NASA Technical Reports Server (NTRS)
Stump, Craig S.; Balon, Thomas W.; Tipton, Charles M.
1992-01-01
The effect of simulated microgravity on the insulin- and exercise-stimulated glucose uptake and metabolism in the hindlimb muscles of rats was investigated using three groups of rats suspended at 45 head-down tilt (SUS) for 14 days: (1) cage control, (2) exercising (treadmill running) control, and (3) rats subjected to suspension followed by exercise (SUS-E). It was found that the suspension of rats with hindlimbs non-weight bearing led to enhanced muscle responses to insulin and exercise, when these stimuli were applied separately. However, the insulin affect appeared to be impaired after exercise for the SUS-E rats, especially for the soleus muscle.
System Finds Horizontal Location of Center of Gravity
NASA Technical Reports Server (NTRS)
Johnston, Albert S.; Howard, Richard T.; Brewster, Linda L.
2006-01-01
An instrumentation system rapidly and repeatedly determines the horizontal location of the center of gravity of a laboratory vehicle that slides horizontally on three air bearings (see Figure 1). Typically, knowledge of the horizontal center-of-mass location of such a vehicle is needed in order to balance the vehicle properly for an experiment and/or to assess the dynamic behavior of the vehicle. The system includes a load cell above each air bearing, electronic circuits that generate digital readings of the weight on each load cell, and a computer equipped with software that processes the readings. The total weight and, hence, the mass of the vehicle are computed from the sum of the load-cell weight readings. Then the horizontal position of the center of gravity is calculated straightforwardly as the weighted sum of the known position vectors of the air bearings, the contribution of each bearing being proportional to the weight on that bearing. In the initial application for which this system was devised, the center- of-mass calculation is particularly simple because the air bearings are located at corners of an equilateral triangle. However, the system is not restricted to this simple geometry. The system acquires and processes weight readings at a rate of 800 Hz for each load cell. The total weight and the horizontal location of the center of gravity are updated at a rate of 800/3 approx. equals 267 Hz. In a typical application, a technician would use the center-of-mass output of this instrumentation system as a guide to the manual placement of small weights on the vehicle to shift the center of gravity to a desired horizontal position. Usually, the desired horizontal position is that of the geometric center. Alternatively, this instrumentation system could be used to provide position feedback for a control system that would cause weights to be shifted automatically (see Figure 2) in an effort to keep the center of gravity at the geometric center.
Balance Asymmetry in Parkinson’s Disease and Its Contribution to Freezing of Gait
Boonstra, Tjitske A.; van Vugt, Jeroen P. P.; van der Kooij, Herman; Bloem, Bastiaan R.
2014-01-01
Balance control (the ability to maintain an upright posture) is asymmetrically controlled in a proportion of patients with Parkinson’s disease. Gait asymmetries have been linked to the pathophysiology of freezing of gait. We speculate that asymmetries in balance could contribute to freezing by a) hampering the unloading of the stepping leg and/or b) leading to a preferred stance leg during gait, which then results in asymmetric gait. To investigate this, we examined the relationship between balance control and weight-bearing asymmetries and freezing. We included 20 human patients with Parkinson (tested OFF medication; nine freezers) and nine healthy controls. Balance was perturbed in the sagittal plane, using continuous multi-sine perturbations, applied by a motion platform and by a force at the sacrum. Applying closed-loop system identification techniques, relating the body sway angle to the joint torques of each leg separately, determined the relative contribution of each ankle and hip joint to the total amount of joint torque. We also calculated weight-bearing asymmetries. We determined the 99-percent confidence interval of weight-bearing and balance-control asymmetry using the responses of the healthy controls. Freezers did not have larger asymmetries in weight bearing (p = 0.85) nor more asymmetrical balance control compared to non-freezers (p = 0.25). The healthy linear one-to-one relationship between weight bearing and balance control was significantly different for freezers and non-freezers (p = 0.01). Specifically, non-freezers had a significant relationship between weight bearing and balance control (p = 0.02), whereas this relation was not significant for freezers (p = 0.15). Balance control is asymmetrical in most patients (about 75 percent) with Parkinson’s disease, but this asymmetry is not related to freezing. The relationship between weight bearing and balance control seems to be less pronounced in freezers, compared to healthy controls and non-freezers. However, this relationship should be investigated further in larger groups of patients. PMID:25032994
Effects of pivoting neuromuscular training on pivoting control and proprioception.
Lee, Song Joo; Ren, Yupeng; Chang, Alison H; Geiger, François; Zhang, Li-Qun
2014-07-01
Pivoting neuromuscular control and proprioceptive acuity may play an important role in anterior cruciate ligament injuries. The goal of this study was to investigate whether pivoting off-axis intensity adjustable neuromuscular control training (POINT) could improve pivoting neuromuscular control, proprioceptive acuity, and functional performance. Among 41 subjects, 21 subjects participated in 18 sessions of POINT (three sessions per week for 6 wk), and 20 subjects served as controls who did their regular workout. Both groups received pre-, mid-, and postintervention evaluations. Propensity score analysis with multivariable regression adjustment was used to investigate the effect of training on pivoting neuromuscular control (pivoting instability, leg pivoting stiffness, maximum internal, and external pivoting angles), proprioceptive acuity, and functional performance in both groups. Compared with the control group, the training group significantly improved pivoting neuromuscular control as reduced pivoting instability, reduced maximum internal and external pivoting angles, increased leg pivoting stiffness, and decreased entropy of time to peak EMG in the gluteus maximus and lateral gastrocnemius under pivoting perturbations. Furthermore, the training group enhanced weight-bearing proprioceptive acuity and improved the single leg hop distance. Improvement of pivoting neuromuscular control in functional weight-bearing activities and task performances after POINT may help develop lower limb injury prevention and rehabilitation methods to reduce anterior cruciate ligament and other musculoskeletal injuries associated with pivoting sports.
Weight-bearing asymmetries during Sit-To-Stand in patients with mild-to-moderate hip osteoarthritis.
Eitzen, Ingrid; Fernandes, Linda; Nordsletten, Lars; Snyder-Mackler, Lynn; Risberg, May Arna
2014-02-01
The Sit-To-Stand (STS) transition is a mechanically demanding task that may pose particular challenges for individuals with lower limb osteoarthritis (OA). Biomechanical features of STS have been investigated in patients with OA, but not in patients with early stage hip OA. The purpose of this study was to explore inter-limb weight-bearing asymmetries (WBA) and selected kinematic and kinetic variables during STS in patients with mild-to-moderate hip OA compared with healthy controls. Twenty-one hip OA patients and 23 controls were included in the study. Sagittal and frontal plane kinematic and kinetic data were collected using an eight-camera motion analysis system synchronized with two force plates embedded in the floor. There were no distinctive biomechanical alterations in sagittal or frontal plane kinematics or kinetics, movement time, or time to reach peak ground reaction force (GRF) in hip OA patients compared with controls. However, the hip OA patients revealed a distinct pattern of WBA compared with the controls, in unloading their involved limb by 18.4% at peak GRF. These findings indicate that patients with early stage hip OA are not yet forced into a stereotypical movement strategy for STS; however, the observed pattern of WBA requires clinical attention. Copyright © 2013 Elsevier B.V. All rights reserved.
Effects of Pivoting Neuromuscular Training on Pivoting Control and Proprioception
Lee, Song Joo; Ren, Yupeng; Chang, Alison H.; Geiger, François; Zhang, Li-Qun
2014-01-01
Purpose Pivoting neuromuscular control and proprioceptive acuity may play an important role in ACL injuries. The goal of this study was to investigate whether pivoting neuromuscular training on an offaxis elliptical trainer (POINT) could improve pivoting neuromuscular control, proprioceptive acuity, and functional performance. Methods Among 41 subjects, 21 subjects participated in 18 sessions of POINT (3 sessions/week for 6 weeks), and 20 subjects served as controls who did their regular workout. Both groups received pre-, mid-, and post-intervention evaluations. Propensity score analysis with multivariable regression adjustment was used to investigate the effect of training on pivoting neuromuscular control (pivoting instability, leg pivoting stiffness, maximum internal and external pivoting angles), proprioceptive acuity, and functional performance in both groups. Results Compared to the control group, the training group significantly improved pivoting neuromuscular control as reduced pivoting instability, reduced maximum internal and external pivoting angles, increased leg pivoting stiffness, and decreased entropy of time to peak EMG in the gluteus maximus and lateral gastrocnemius under pivoting perturbations. Furthermore, the training group enhanced weight-bearing proprioceptive acuity and improved the single leg hop distance. Conclusion Improvement of pivoting neuromuscular control in functional weight-bearing activities and task performances following POINT may help develop lower limb injury prevention and rehabilitation methods to reduce ACL and other musculoskeletal injuries associated with pivoting sports. PMID:24389517
NASA Astrophysics Data System (ADS)
Gireesh Kumar, Pala; Jayalekshmi, S.
2018-03-01
Wheel-soil Interaction studies are gaining momentum in the field of Terramechanics, but the basis is Terzaghi’s bearing capacity equation. For the current study, on a lunar soil simulant TRI – 1, two plain rigid wheels are considered, i.e., small wheel (dia. of 210 mm and width of 50 mm) and large wheel (dia. 160 mm and width 32 mm). Also, different number of lugs (N = 8, 12, 16) with various lug heights (h = 5 mm, 10 mm, 15 mm) are used. In this paper, the variation of wheel sinkages from experiments obtained for various wheel weights are examined and presented. The parameter, Coefficient of rolling resistance (CRR) is determined for various cases. Hence, rolling resistance was determined and examined from the obtained CRR for all cases. Among the cases examined, the large wheel with weight 67.44 N for plain wheels and weight 67.85 N for lugged wheel (no. of lugs = 16, and height of lugs = 5 mm) registered better mobility. Similarly, for small wheel with weight 52.189 N for plain wheel and weight 52.481 N for lugged wheel (no. of lugs = 16, and height of lugs = 5 mm) registered better mobility, a lesser rolling resistance for these cases.
NASA Technical Reports Server (NTRS)
Musacchia, X. J.; Steffen, J. M.
1984-01-01
Suspension systems are used to simulate hypokinetic/hypodynamic (H/H) and anitorthostatic (AO) responses seen under conditions of weightlessness. Growing rats in H/H suspension with unloaded hindlimbs for one and two weeks respond with muscle atrophy and increased excretion of nitrogenous end products such as urea, NH3 and 3 methyl histidine. Since muscle is in a dynamic state of synthesis and breakdown of protein, relationships between protein, RNA and DNA contents in the four muscles which reflect weight bearing and non-weight bearing functions were assessed. Protein and RNA progressively decreased over a one and two week period of H/H suspension: soleus gastrocnemius=plantaris EDL. Concommitant analysis of DNA contents showed there were no changes. The interpretation was that protein synthesis was slowed during H/H. As with muscle mass, protein and RNA levels recovered rapidly after removal from H/H. The AO rats (which are also H/H) respond with diuresis, natriuresis and kaliuresis in a manner comparable to responses seen when thoracic blood vessels are volume loaded.
Biomechanical study on axillary crutches during single-leg swing-through gait.
Goh, J C; Toh, S L; Bose, K
1986-08-01
This paper describes a kinetic and kinematic study on axillary crutches during one-leg swing-through gait. The primary objective is to evaluate the interplay of forces at the crutch and body interfaces and to relate them in the understanding of problems associated with the use of axillary crutches. Ten normal adult male subjects with simulated left leg impairment participated in the study. For data acquisition, the VICON kinematic system, a Kistler force plate and an instrumented crutch (with force transducers at the two upper struts close to the axillary bar and one near the crutch tip) were used. Results showed that the peak ground reaction force on the weight-bearing leg during lower limb stance increased by 21.6 percent bodyweight. The peak reaction force transmitted to the arm during crutch stance was 44.4 percent bodyweight. These increased loadings could be detrimental to patients with unsound weight-bearing leg and upper extremities respectively. When the crutches were used incorrectly, 34 percent bodyweight was carried by the underarm. This could cause undue pressure over the neurovascular structures at the axillary region.
Kurtosis based weighted sparse model with convex optimization technique for bearing fault diagnosis
NASA Astrophysics Data System (ADS)
Zhang, Han; Chen, Xuefeng; Du, Zhaohui; Yan, Ruqiang
2016-12-01
The bearing failure, generating harmful vibrations, is one of the most frequent reasons for machine breakdowns. Thus, performing bearing fault diagnosis is an essential procedure to improve the reliability of the mechanical system and reduce its operating expenses. Most of the previous studies focused on rolling bearing fault diagnosis could be categorized into two main families, kurtosis-based filter method and wavelet-based shrinkage method. Although tremendous progresses have been made, their effectiveness suffers from three potential drawbacks: firstly, fault information is often decomposed into proximal frequency bands and results in impulsive feature frequency band splitting (IFFBS) phenomenon, which significantly degrades the performance of capturing the optimal information band; secondly, noise energy spreads throughout all frequency bins and contaminates fault information in the information band, especially under the heavy noisy circumstance; thirdly, wavelet coefficients are shrunk equally to satisfy the sparsity constraints and most of the feature information energy are thus eliminated unreasonably. Therefore, exploiting two pieces of prior information (i.e., one is that the coefficient sequences of fault information in the wavelet basis is sparse, and the other is that the kurtosis of the envelope spectrum could evaluate accurately the information capacity of rolling bearing faults), a novel weighted sparse model and its corresponding framework for bearing fault diagnosis is proposed in this paper, coined KurWSD. KurWSD formulates the prior information into weighted sparse regularization terms and then obtains a nonsmooth convex optimization problem. The alternating direction method of multipliers (ADMM) is sequentially employed to solve this problem and the fault information is extracted through the estimated wavelet coefficients. Compared with state-of-the-art methods, KurWSD overcomes the three drawbacks and utilizes the advantages of both family tools. KurWSD has three main advantages: firstly, all the characteristic information scattered in proximal sub-bands is gathered through synthesizing those impulsive dominant sub-band signals and thus eliminates the dilemma of the IFFBS phenomenon. Secondly, the noises in the focused sub-bands could be alleviated efficiently through shrinking or removing the dense wavelet coefficients of Gaussian noise. Lastly, wavelet coefficients with faulty information are reliably detected and preserved through manipulating wavelet coefficients discriminatively based on the contribution to the impulsive components. Moreover, the reliability and effectiveness of the KurWSD are demonstrated through simulated and experimental signals.
49 CFR 229.69 - Side bearings.
Code of Federal Regulations, 2010 CFR
2010-10-01
....69 Side bearings. (a) Friction side bearings with springs designed to carry weight may not have more than 25 percent of the springs in any one nest broken. (b) Friction side bearings may not be run in...
49 CFR 229.69 - Side bearings.
Code of Federal Regulations, 2012 CFR
2012-10-01
....69 Side bearings. (a) Friction side bearings with springs designed to carry weight may not have more than 25 percent of the springs in any one nest broken. (b) Friction side bearings may not be run in...
49 CFR 229.69 - Side bearings.
Code of Federal Regulations, 2011 CFR
2011-10-01
....69 Side bearings. (a) Friction side bearings with springs designed to carry weight may not have more than 25 percent of the springs in any one nest broken. (b) Friction side bearings may not be run in...
49 CFR 229.69 - Side bearings.
Code of Federal Regulations, 2013 CFR
2013-10-01
....69 Side bearings. (a) Friction side bearings with springs designed to carry weight may not have more than 25 percent of the springs in any one nest broken. (b) Friction side bearings may not be run in...
49 CFR 229.69 - Side bearings.
Code of Federal Regulations, 2014 CFR
2014-10-01
....69 Side bearings. (a) Friction side bearings with springs designed to carry weight may not have more than 25 percent of the springs in any one nest broken. (b) Friction side bearings may not be run in...
Design and fabrication of the Brayton rotating unit
NASA Technical Reports Server (NTRS)
Davis, J. E.
1972-01-01
The Brayton rotating unit (BRU), operating on a gas bearing system, has been designed, fabricated, and demonstrated for use in a closed Brayton cycle space power conversion system. The BRU uses a binary mixture of xenon and helium (molecular weight, 83.8) as the cycle working fluid and bearing lubricating medium and was designed to produce from 2.25 to 10.5 kw sub e of 1200 Hz three-phase electrical power. The single-shaft rotating assembly operates at a design speed of 36,000 rpm and comprises a radial single-stage compressor, a four-pole Rice alternator rotor, and a radial inflow turbine. Four units, a dynamic simulator and three component research packages, were supplied to the NASA Lewis Research Center for performance testing and further development.
NASA Technical Reports Server (NTRS)
Beatty, R. F.; Hine, M. J.
1986-01-01
The high pressure turbomachinery of the Space Shuttle Main Engine has the highest power-to-weight ratio of any operational machine known. Subsynchronous rotor whirl of the high pressure oxygen turbopump occurred in development testing at full-power level (109 percent thrust). The means by which the turbopump was successfully uprated is presented herein. The subsynchronous motion was determined to be driven by impeller destabilizing forces in combination with low net damping and bearing degradation. The degradation resulted from ball wear due primarily to an excessive loading condition of operating too near the lightly damped rotor second critical speed while under a large static load and, secondarily, from reverse bearing loading or loss of internal clearance and coolant during simulated flight conditions. The rotor response was reduced by stiffening the shaft and supports, optimizing the stiffness and damping of annular seals, and increasing the bearing deadband. The uprated oxygen turbopump configuration was verified by converting the pump and bearing support into a load cell for the purpose of systematically quantifying the load reduction benefits relative to baseline turbopumps. The damped second critical speed margin and the load sharing have been substantially improved which has resulted in reduced bearing loads for improved service life of the machine at full-power level.
REISTETTER, TIMOTHY; ABREU, BEATRIZ C.; BEAR-LEHMAN, JANE; OTTENBACHER, KENNETH J.
2010-01-01
The purpose of the study was to investigate the effect of upper extremity (UE) weight bearing on UE impairment functional performance of persons with acquired brain injury (BI). A quasi-experimental design was used to examine a convenience sample of 99 persons with acquired BI and 22 without BI (WBI) living in a community re-entry centre. A computerized force-sensing array pressure map system was used to determine the UE pressure during unilateral and bilateral conditions. Differences between groups were examined using t-tests. Correlations were computed between UE weight bearing and hand function, and functional performance as measured by the Fugl-Meyer scale and functional independence measure (FIM) scale. The group of people with BI exerted significantly lower UE weight bearing during unilateral conditions as compared with persons WBI [left: t (119) = 2.34, p = 0.021; right: t (119) = 4.79, p = 0.043). UE weight-bearing measures correlated strongly with FIM motor scores with bilateral UE conditions yielded the highest significant correlation (bilateral left r = 0.487, p < 0.001; bilateral right r = 0.469, p < 0.01). The results indicated that UE weight-bearing pressure differs in unilateral and bilateral conditions, between persons with and WBI and between persons with stroke and traumatic brain injury. These findings may have implications for occupational therapists that use unilateral versus bilateral motor training for rehabilitation. There is a need to replicate the study design with a randomized and stratified sample of persons with BI. PMID:19551694
Unver, Bayram; Karatosun, Vasfi; Gunal, Izge; Angin, Salih
2004-02-01
Weight bearing after total hip arthroplasty is postponed in order to prevent early loosening, but this negatively affects the rehabilitation programme. For the force transfer characteristics of thrust plate prosthesis (TPP), a new type of hip prosthesis used without cement is similar to the normal hip. We evaluated the possibilities of early weight bearing after TPP by comparing early partial with early full weight bearing. Randomized controlled study. Department of orthopaedics and traumatology in a university hospital. Sixty hips of 51 patients who underwent total hip arthroplasty with TPP were randomly assigned into two groups. Both groups received accelerated rehabilitation programmes: group 1 with early partial weight bearing and group 2 with early full weight bearing. Patients were evaluated by a blind observer preoperatively, at three months after surgery by clinical (measurement of range of hip motion (universal goniometry), muscle strength (Manual Muscle Test), functional test (6-minute walk test), hip function (Harris Hip Scoring System)) and radiographical parameters and one year after surgery by clinical (Harris Hip Scoring System) and radiographical parameters. Group 2 performed transfer activities earlier, had more walking distance at the time of discharge and shorter hospital stay than group 1. At three months, Harris Hip Score, muscle strength, 6-minute walk test, and duration of crutch use were significantly (p < 0.05) in favour of group 2. None of the patients in either group showed signs of loosening one year after the operation. These results suggest that patients with TPP can tolerate an accelerated rehabilitation programme with early weight bearing and will gain the goals of rehabilitation earlier.
Gait analysis and weight bearing in pre-clinical joint pain research.
Ängeby Möller, Kristina; Svärd, Heta; Suominen, Anni; Immonen, Jarmo; Holappa, Johanna; Stenfors, Carina
2018-04-15
There is a need for better joint pain treatment, but development of new medication has not been successful. Pre-clinical models with readouts that better reflect the clinical situation are needed. In patients with joint pain, pain at rest and pain at walking are two major complaints. We describe a new way of calculating results from gait analysis using the CatWalk™ setup. Rats with monoarthritis induced by injection of Complete Freund's Adjuvant (CFA) intra-articularly into the ankle joint of one hind limb were used to assess gait and dynamic weight bearing. The results show that dynamic weight bearing was markedly reduced for the injected paw. Gait parameters such as amount of normal step sequences, walking speed and duration of step placement were also affected. Treatment with naproxen (an NSAID commonly used for inflammatory pain) attenuated the CFA-induced effects. Pregabalin, which is used for neuropathic pain, had no effect. Reduced dynamic weight bearing during locomotion, assessed and calculated in the way we present here, showed a dose-dependent and lasting normalization after naproxen treatment. In contrast, static weight bearing while standing (Incapacitance tester) showed a significant effect for a limited time only. Mechanical sensitivity (von Frey Optihairs) was completely normalized by naproxen, and the window for testing pharmacological effect disappeared. Objective and reproducible effects, with an endpoint showing face validity compared to pain while walking in patients with joint pain, are achieved by a new way of calculating dynamic weight bearing in monoarthritic rats. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Deng, Feiyue; Yang, Shaopu; Tang, Guiji; Hao, Rujiang; Zhang, Mingliang
2017-04-01
Wheel bearings are essential mechanical components of trains, and fault detection of the wheel bearing is of great significant to avoid economic loss and casualty effectively. However, considering the operating conditions, detection and extraction of the fault features hidden in the heavy noise of the vibration signal have become a challenging task. Therefore, a novel method called adaptive multi-scale AVG-Hat morphology filter (MF) is proposed to solve it. The morphology AVG-Hat operator not only can suppress the interference of the strong background noise greatly, but also enhance the ability of extracting fault features. The improved envelope spectrum sparsity (IESS), as a new evaluation index, is proposed to select the optimal filtering signal processed by the multi-scale AVG-Hat MF. It can present a comprehensive evaluation about the intensity of fault impulse to the background noise. The weighted coefficients of the different scale structural elements (SEs) in the multi-scale MF are adaptively determined by the particle swarm optimization (PSO) algorithm. The effectiveness of the method is validated by analyzing the real wheel bearing fault vibration signal (e.g. outer race fault, inner race fault and rolling element fault). The results show that the proposed method could improve the performance in the extraction of fault features effectively compared with the multi-scale combined morphological filter (CMF) and multi-scale morphology gradient filter (MGF) methods.
Exploring biological interaction networks with tailored weighted quasi-bicliques
2012-01-01
Background Biological networks provide fundamental insights into the functional characterization of genes and their products, the characterization of DNA-protein interactions, the identification of regulatory mechanisms, and other biological tasks. Due to the experimental and biological complexity, their computational exploitation faces many algorithmic challenges. Results We introduce novel weighted quasi-biclique problems to identify functional modules in biological networks when represented by bipartite graphs. In difference to previous quasi-biclique problems, we include biological interaction levels by using edge-weighted quasi-bicliques. While we prove that our problems are NP-hard, we also describe IP formulations to compute exact solutions for moderately sized networks. Conclusions We verify the effectiveness of our IP solutions using both simulation and empirical data. The simulation shows high quasi-biclique recall rates, and the empirical data corroborate the abilities of our weighted quasi-bicliques in extracting features and recovering missing interactions from biological networks. PMID:22759421
Neuromodulation of the lumbar spinal locomotor circuit.
AuYong, Nicholas; Lu, Daniel C
2014-01-01
The lumbar spinal cord contains the necessary circuitry to independently drive locomotor behaviors. This function is retained following spinal cord injury (SCI) and is amenable to rehabilitation. Although the effectiveness of task-specific training and pharmacologic modulation has been repeatedly demonstrated in animal studies, results from human studies are less striking. Recently, lumbar epidural stimulation (EDS) along with locomotor training was shown to restore weight-bearing function and lower-extremity voluntary control in a chronic, motor-complete human SCI subject. Related animal studies incorporating EDS as part of the therapeutic regiment are also encouraging. EDS is emerging as a promising neuromodulatory tool for SCI. Copyright © 2014 Elsevier Inc. All rights reserved.
Estimating Potential Effects of Hypothetical Oil Spills on Polar Bears
Amstrup, Steven C.; Durner, George M.; McDonald, T.L.; Johnson, W.R.
2006-01-01
Much is known about the transport and fate of oil spilled into the sea and its toxicity to exposed wildlife. Previously, however, there has been no way to quantify the probability that wildlife dispersed over the seascape would be exposed to spilled oil. Polar bears, the apical predator of the arctic, are widely dispersed near the continental shelves of the Arctic Ocean, an area also undergoing considerable hydrocarbon exploration and development. We used 15,308 satellite locations from 194 radiocollared polar bears to estimate the probability that polar bears could be exposed to hypothetical oil spills. We used a true 2 dimensional Gausian kernel density estimator, to estimate the number of bears likely to occur in each 1.00 km2 cell of a grid superimposed over near shore areas surrounding 2 oil production facilities: the existing Northstar oil production facility, and the proposed offshore site for the Liberty production facility. We estimated the standard errors of bear numbers per cell with bootstrapping. Simulated oil spill footprints for September and October, the times during which we hypothesized effects of an oil-spill would be worst, were estimated using real wind and current data collected between 1980 and 1996. We used ARC/Info software to calculate overlap (numbers of bears oiled) between simulated oil-spill footprints and polar bear grid-cell values. Numbers of bears potentially oiled by a hypothetical 5912 barrel spill (the largest spill thought probable from a pipeline breach) ranged from 0 to 27 polar bears for September open water conditions, and from 0 to 74 polar bears in October mixed ice conditions. Median numbers oiled by the 5912 barrel hypothetical spill from the Liberty simulation in September and October were 1 and 3 bears, equivalent values for the Northstar simulation were 3 and 11 bears. In October, 75% of trajectories from the 5912 barrel simulated spill at Liberty oiled 9 or fewer bears while 75% of the trajectories affected 20 or fewer polar bears when we simulated an October spill at the Northstar site. Northstar Island is nearer the active ice flaw zone than Liberty. Simulations suggested that oil spilled at Northstar would spread more effectively and more consistently into surrounding areas. Also, polar bear densities are consistently higher near Northstar. Oil spills simulated for the Liberty site were more erratic in the areas they covered and the numbers of bears impacted, and numbers of bears hypothetically exposed were usually smaller. Methods described here are broadly applicable to other dispersed marine wildlife. Key words: Arctic, Beaufort Sea, clustering, kernel, management, oil spill, polar bears, population delineation, radiotelemetry, satellite, smoothing, Ursus maritimus
Toward a 3D dynamic model of a faulty duplex ball bearing
NASA Astrophysics Data System (ADS)
Kogan, Gideon; Klein, Renata; Kushnirsky, Alex; Bortman, Jacob
2015-03-01
Bearings are vital components for safe and proper operation of machinery. Increasing efficiency of bearing diagnostics usually requires training of health and usage monitoring systems via expensive and time-consuming ground calibration tests. The main goal of this research, therefore, is to improve bearing dynamics modeling tools in order to reduce the time and budget needed to implement the health and usage monitoring approach. The proposed three-dimensional ball bearing dynamic model is based on the classic dynamic and kinematic equations. Interactions between the bodies are simulated using non-linear springs combined with dampers described by Hertz-type contact relation. The force friction is simulated using the hyperbolic-tangent function. The model allows simulation of a wide range of mechanical faults. It is validated by comparison to known bearing behavior and to experimental results. The model results are verified by demonstrating numerical convergence. The model results for the two cases of single and duplex angular ball bearings with axial deformation in the outer ring are presented. The qualitative investigation provides insight into bearing dynamics, the sensitivity study generalizes the qualitative findings for similar cases, and the comparison to the test results validates model reliability. The article demonstrates the variety of the cases that the 3D bearing model can simulate and the findings to which it may lead. The research allowed the identification of new patterns generated by single and duplex bearings with axially deformed outer race. It also enlightened the difference between single and duplex bearing manifestation. In the current research the dynamic model enabled better understanding of the physical behavior of the faulted bearings. Therefore, it is expected that the modeling approach has the potential to simplify and improve the development process of diagnostic algorithms. • A deformed outer race of a single axially loaded bearing is simulated. • The model results are subjected to a sensitivity study. • Duplex bearing with deformed outer race is simulated as well as tested. • The simulation results are in a good agreement with the experimental results.
Working Performance Analysis of Rolling Bearings Used in Mining Electric Excavator Crowd Reducer
NASA Astrophysics Data System (ADS)
Zhang, Y. H.; Hou, G.; Chen, G.; Liang, J. F.; Zheng, Y. M.
2017-12-01
Refer to the statistical load data of digging process, on the basis of simulation analysis of crowd reducer system dynamics, the working performance simulation analysis of rolling bearings used in crowd reducer of large mining electric excavator is completed. The contents of simulation analysis include analysis of internal load distribution, rolling elements contact stresses and rolling bearing fatigue life. The internal load characteristics of rolling elements in cylindrical roller bearings are obtained. The results of this study identified that all rolling bearings satisfy the requirements of contact strength and fatigue life. The rationality of bearings selection and arrangement is also verified.
Weights and hematology of wild black bears during hibernation
DelGiudice, Glenn D.; Rogers, Lynn L.; Allen, Arthur W.; Seal, U.S.
1991-01-01
We compared weights and hematological profiles of adult (greater than 3-yr-old) female black bears (Ursus americanus) during hibernation (after 8 January). We handled 28 bears one to four times (total of 47) over 4 yr of varying mast and berry production. Mean weight of lactating bears was greater (P less than 0.0001) than that of non-lactating females. White blood cells (P less than 0.05) and mean corpuscular volume (P = 0.005) also differed between lactating and non-lactating bears. Hemoglobin (P = 0.006) and mean corpuscular hemoglobin concentration (P = 0.02) varied among years; values were lowest during 1975, following decreased precipitation and the occurrence of a second year of mast and berry crop shortages in a three-year period. Significant (P less than 0.05) interaction between reproductive status (lactating versus non-lactating) and study year for hemoglobin, red blood cells, and packed cell volume, and increased mean corpuscular volume, suggested a greater nutritional challenge for lactating females compared to non-lactating females during the 1975 denning season. Our data suggest that hematological characteristics of denning bears may be more sensitive than weights as indicators of annual changes in nutritional status; however, other influential factors, in addition to mast and berry crop production, remain to be examined.
McKeon, Gabriel P; Pacharinsak, Cholawat; Long, Charles T; Howard, Antwain M; Jampachaisri, Katechan; Yeomans, David C; Felt, Stephen A
2011-01-01
Postoperative pain management in laboratory animals relies heavily on a limited number of drug classes, such as opioids and nonsteroidal antiinflammatory drugs. Here we evaluated the effects of saline, tramadol, tramadol with gabapentin, and buprenorphine (n = 6 per group) in a rat model of incisional pain by examining thermal hyperalgesia and weight-bearing daily for 6 d after surgery. All drugs were administered preemptively and continued for 2 consecutive days after surgery. Rats treated with saline or with tramadol only showed thermal hyperalgesia on days 1 through 4 and 1 through 3 after surgery, respectively. In contrast, buprenorphine-treated rats showed no thermal hyperalgesia on days 1 and 2 after surgery, and rats given tramadol with gabapentin showed reduced thermal hyperalgesia on days 2 and 4. For tests of weight-bearing, rats treated with saline or with tramadol only showed significantly less ipsilateral weight-bearing on day 1 after surgery, whereas rats given either buprenorphine or tramadol with gabapentin showed no significant change in ipsilateral weight-bearing after surgery. These data suggest that tramadol alone provides insufficient analgesia in this model of incisional pain; buprenorphine and, to a lesser extent, tramadol with gabapentin provide relief of thermal hyperalgesia and normalize weight-bearing. PMID:21439212
Research on safety evaluation model for in-vehicle secondary task driving.
Jin, Lisheng; Xian, Huacai; Niu, Qingning; Bie, Jing
2015-08-01
This paper presents a new method for evaluating in-vehicle secondary task driving safety. There are five in-vehicle distracter tasks: tuning the radio to a local station, touching the touch-screen telephone menu to a certain song, talking with laboratory assistant, answering a telephone via Bluetooth headset, and finding the navigation system from Ipad4 computer. Forty young drivers completed the driving experiment on a driving simulator. Measures of fixations, saccades, and blinks are collected and analyzed. Based on the measures of driver eye movements which have significant difference between the baseline and secondary task driving conditions, the evaluation index system is built. The Analytic Network Process (ANP) theory is applied for determining the importance weight of the evaluation index in a fuzzy environment. On the basis of the importance weight of the evaluation index, Fuzzy Comprehensive Evaluation (FCE) method is utilized to evaluate the secondary task driving safety. Results show that driving with secondary tasks greatly distracts the driver's attention from road and the evaluation model built in this study could estimate driving safety effectively under different driving conditions. Crown Copyright © 2014. Published by Elsevier Ltd. All rights reserved.
Coordination Polymerization of Renewable 3-Methylenecyclopentene with Rare-Earth-Metal Precursors.
Liu, Bo; Li, Shihui; Wang, Meiyan; Cui, Dongmei
2017-04-10
Coordination polymerization of renewable 3-methylenecyclopentene has been investigated for the first time using rare-earth metal-based precursors bearing various bulky ligands. All the prepared complexes catalyze controllable polymerization of 3-methylenecyclopentene into high molecular weight polymers, of which the NPN- and NSN-tridentate non-Cp ligated lutetium-based catalytic systems exhibited extremely high activities up to 11 520 kg/(mol Lu ⋅h) in a dilute toluene solution (3.2 g/100 mL) at room temperature. The resultant polymers have pure 1,4-regioregularity (>99 %) and tailorable number average molecular weights (1-20×10 4 ) with narrow molecular weight distributions (polydispersity index (PDI)=1.45-1.79). DFT simulations were employed to study the polymerization mechanism and stereoregularity control. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.
Aerospace applications of magnetic bearings
NASA Technical Reports Server (NTRS)
Downer, James; Goldie, James; Gondhalekar, Vijay; Hockney, Richard
1994-01-01
Magnetic bearings have traditionally been considered for use in aerospace applications only where performance advantages have been the primary, if not only, consideration. Conventional wisdom has been that magnetic bearings have certain performance advantages which must be traded off against increased weight, volume, electric power consumption, and system complexity. These perceptions have hampered the use of magnetic bearings in many aerospace applications because weight, volume, and power are almost always primary considerations. This paper will review progress on several active aerospace magnetic bearings programs at SatCon Technology Corporation. The magnetic bearing programs at SatCon cover a broad spectrum of applications including: a magnetically-suspended spacecraft integrated power and attitude control system (IPACS), a magnetically-suspended momentum wheel, magnetic bearings for the gas generator rotor of a turboshaft engine, a vibration-attenuating magnetic bearing system for an airborne telescope, and magnetic bearings for the compressor of a space-rated heat pump system. The emphasis of these programs is to develop magnetic bearing technologies to the point where magnetic bearings can be truly useful, reliable, and well tested components for the aerospace community.
Aerospace applications of magnetic bearings
NASA Astrophysics Data System (ADS)
Downer, James; Goldie, James; Gondhalekar, Vijay; Hockney, Richard
1994-05-01
Magnetic bearings have traditionally been considered for use in aerospace applications only where performance advantages have been the primary, if not only, consideration. Conventional wisdom has been that magnetic bearings have certain performance advantages which must be traded off against increased weight, volume, electric power consumption, and system complexity. These perceptions have hampered the use of magnetic bearings in many aerospace applications because weight, volume, and power are almost always primary considerations. This paper will review progress on several active aerospace magnetic bearings programs at SatCon Technology Corporation. The magnetic bearing programs at SatCon cover a broad spectrum of applications including: a magnetically-suspended spacecraft integrated power and attitude control system (IPACS), a magnetically-suspended momentum wheel, magnetic bearings for the gas generator rotor of a turboshaft engine, a vibration-attenuating magnetic bearing system for an airborne telescope, and magnetic bearings for the compressor of a space-rated heat pump system. The emphasis of these programs is to develop magnetic bearing technologies to the point where magnetic bearings can be truly useful, reliable, and well tested components for the aerospace community.
Can flexibility help you float?
NASA Astrophysics Data System (ADS)
Burton, L. J.; Bush, J. W. M.
2012-10-01
We consider the role of flexibility in the weight-bearing characteristics of bodies floating at an interface. Specifically, we develop a theoretical model for a two-dimensional thin floating plate that yields the maximum stable plate load and optimal stiffness for weight support. Plates small relative to the capillary length are primarily supported by surface tension, and their weight-bearing potential does not benefit from flexibility. Above a critical size comparable to the capillary length, flexibility assists interfacial flotation. For plates on the order of and larger than the capillary length, deflection from an initially flat shape increases the force resulting from hydrostatic pressure, allowing the plate to support a greater load. In this large plate limit, the shape that bears the most weight is a semicircle, which displaces the most fluid above the plate for a fixed plate length. Exact results for maximum weight-bearing plate shapes are compared to analytic approximations made in the limits of large and small plate sizes. The value of flexibility for floating to a number of biological organisms is discussed in light of our study.
Padilha, Camila Souza; Borges, Fernando Henrique; Costa Mendes da Silva, Lilian Eslaine; Frajacomo, Fernando Tadeu Trevisan; Jordao, Alceu Afonso; Duarte, José Alberto; Cecchini, Rubens; Guarnier, Flávia Alessandra; Deminice, Rafael
2017-09-01
The aim of this study was to investigate the effects of resistance exercise training (RET) on oxidative stress, systemic inflammatory markers, and muscle wasting in Walker-256 tumor-bearing rats. Male (Wistar) rats were divided into 4 groups: sedentary controls (n = 9), tumor-bearing (n = 9), exercised (n = 9), and tumor-bearing exercised (n = 10). Exercised and tumor-bearing exercised rats were exposed to resistance exercise of climbing a ladder apparatus with weights tied to their tails for 6 weeks. The physical activity of control and tumor-bearing rats was confined to the space of the cage. After this period, tumor-bearing and tumor-bearing exercised animals were inoculated subcutaneously with Walker-256 tumor cells (11.0 × 10 7 cells in 0.5 mL of phosphate-buffered saline) while control and exercised rats were injected with vehicle. Following inoculation, rats maintained resistance exercise training (exercised and tumor-bearing exercised) or sedentary behavior (control and tumor-bearing) for 12 more days, after which they were euthanized. Results showed muscle wasting in the tumor-bearing group, with body weight loss, increased systemic leukocytes, and inflammatory interleukins as well as muscular oxidative stress and reduced mTOR signaling. In contrast, RET in the tumor-bearing exercised group was able to mitigate the reduced body weight and muscle wasting with the attenuation of muscle oxidative stress and systemic inflammatory markers. RET also prevented loss of muscle strength associated with tumor development. RET, however, did not prevent the muscle proteolysis signaling via FBXO32 gene messenger RNA expression in the tumor-bearing group. In conclusion, RET performed prior tumor implantation prevents cachexia development by attenuating tumor-induced systemic pro-inflammatory condition with muscle oxidative stress and muscle damage.
Knee Brace Would Lock And Unlock Automatically
NASA Technical Reports Server (NTRS)
Myers, Neill; Forbes, John; Shadoan, Mike; Baker, Kevin
1995-01-01
Proposed knee brace designed to aid rehabilitation of person who suffered some muscle damage in leg. Not limited to locking in straight-leg position and, instead, locks at any bend angle. Does not prevent knee from bearing weight. Instead, knee brace allows knee to bear weight and locks only when foot and lower leg bear weight. Thus, brace prevents flexion that wearer desired to prevent but could not prevent because of weakened muscles. Knee bends freely to exercise knee-related muscles. Knee brace strapped at upper end to leg above knee, and anchored at lower end by stirrup under foot. Joint mechanism (identical mechanisms used in left and right assemblies) allows knee joint to flex freely except when weight applied to heel.
Influence of hydrodynamic thrust bearings on the nonlinear oscillations of high-speed rotors
NASA Astrophysics Data System (ADS)
Chatzisavvas, Ioannis; Boyaci, Aydin; Koutsovasilis, Panagiotis; Schweizer, Bernhard
2016-10-01
This paper investigates the effect of hydrodynamic thrust bearings on the nonlinear vibrations and the bifurcations occurring in rotor/bearing systems. In order to examine the influence of thrust bearings, run-up simulations may be carried out. To be able to perform such run-up calculations, a computationally efficient thrust bearing model is mandatory. Direct discretization of the Reynolds equation for thrust bearings by means of a Finite Element or Finite Difference approach entails rather large simulation times, since in every time-integration step a discretized model of the Reynolds equation has to be solved simultaneously with the rotor model. Implementation of such a coupled rotor/bearing model may be accomplished by a co-simulation approach. Such an approach prevents, however, a thorough analysis of the rotor/bearing system based on extensive parameter studies. A major point of this work is the derivation of a very time-efficient but rather precise model for transient simulations of rotors with hydrodynamic thrust bearings. The presented model makes use of a global Galerkin approach, where the pressure field is approximated by global trial functions. For the considered problem, an analytical evaluation of the relevant integrals is possible. As a consequence, the system of equations of the discretized bearing model is obtained symbolically. In combination with a proper decomposition of the governing system matrix, a numerically efficient implementation can be achieved. Using run-up simulations with the proposed model, the effect of thrust bearings on the bifurcations points as well as on the amplitudes and frequencies of the subsynchronous rotor oscillations is investigated. Especially, the influence of the magnitude of the axial force, the geometry of the thrust bearing and the oil parameters is examined. It is shown that the thrust bearing exerts a large influence on the nonlinear rotor oscillations, especially to those related with the conical mode of the rotor. A comparison between a full co-simulation approach and a reduced Galerkin implementation is carried out. It is shown that a speed-up of 10-15 times may be obtained with the Galerkin model compared to the co-simulation model under the same accuracy.
Morseth, Bente; Ahmed, Luai A; Bjørnerem, Åshild; Emaus, Nina; Jacobsen, Bjarne K; Joakimsen, Ragnar; Størmer, Jan; Wilsgaard, Tom; Jørgensen, Lone
2012-06-01
Our aim was to examine associations between leisure time physical activity and risk of non-vertebral fractures in men and women aged ≥55 years, with focus on the anatomical fracture location. Self-reported physical activity was registered in 3,450 men and 4,072 women aged 55-97 years at baseline in the Tromsø Study, Norway, in 1994-1995. Non-vertebral fractures were registered through December 31, 2009. During 75,546 person-years at risk, 1,693 non-vertebral fractures were identified. Risk of any non-vertebral fracture decreased with increasing physical activity level in men (P (trend) = 0.006) and non-significantly in women (P (trend) = 0.15), after adjustment for age, body mass index, height, smoking, and previous fracture. The reduced fracture risk was due to a reduced risk in the weight-bearing skeleton, particular at the hip, whereas risk of fracture in the non-weight-bearing skeleton was not related to physical activity. At weight-bearing sites, an inverse relationship between physical activity and fracture risk was present in both sexes (P (trend) ≤ 0.013). Compared with sedentary subjects, the most active men and women had respectively 37% (HR = 0.63, 95% CI: 0.45, 0.88) and 23% (HR = 0.77, 95% CI: 0.62, 0.95) reduced fracture risk in the weight-bearing skeleton. Physical activity is associated with reduced fracture risk at weight-bearing sites, with no associations at non-weight-bearing sites, in both sexes. Habitual physical activity is an important amendable approach to prevent hip fracture.
Tanaka, Ryo; Ozawa, Junya; Kito, Nobuhiro; Moriyama, Hideki
2013-12-01
We performed a systematic review and meta-analysis of randomized controlled trials to investigate the differences in the efficacies between strengthening and aerobic exercises for pain relief in people with knee osteoarthritis. This search was applied to Medline, Cochrane Central Register of Controlled Trials, the Physiotherapy Evidence Database, and the Cumulative Index to Nursing and Allied Health Literature. All literature published from each source's earliest date to March 2013 was included. Trials comparing the effects of exercise intervention with those of either non-intervention or psycho-educational intervention were collected. Meta-analysis was performed for trials in which therapeutic exercise was carried out with more than three sessions per week up to eight weeks, for pain in people with knee osteoarthritis. All trials were categorised into three subgroups (non-weight-bearing strengthening exercise, weight-bearing strengthening exercise, and aerobic exercise). Subgroup analyses were also performed. Data from eight studies were integrated. Overall effect of exercise was significant with a large effect size (standardised mean difference (SMD): -0.94; 95% confidence interval -1.31 to -0.57). Subgroup analyses showed a larger SMD for non-weight-bearing strengthening exercise (-1.42 [-2.09 to -0.75]) compared with weight-bearing strengthening exercise (-0.70 [-1.05 to -0.35]), and aerobic exercise (-0.45 [-0.77 to -0.13]). Muscle strengthening exercises with or without weight-bearing and aerobic exercises are effective for pain relief in people with knee osteoarthritis. In particular, for pain relief by short-term exercise intervention, the most effective exercise among the three types is non-weight-bearing strengthening exercise.
Sutera, R; Iovane, A; Sorrentino, F; Candela, F; Mularo, V; La Tona, G; Midiri, M
2010-03-01
This study assessed the usefulness of upright weight-bearing examination of the ankle/hind foot performed with a dedicated magnetic resonance (MR) imaging scanner in the evaluation of the plantar fascia in healthy volunteers and in patients with clinical evidence of plantar fasciitis. Between January and March 2009, 20 patients with clinical evidence of plantar fasciitis (group A) and a similar number of healthy volunteers (group B) underwent MR imaging of the ankle/hind foot in the upright weight-bearing and conventional supine position. A 0.25-Tesla MR scanner (G-Scan, Esaote SpA, Genoa, Italy) was used with a dedicated receiving coil for the ankle/hind foot. Three radiologists, blinded to patients' history and clinical findings, assessed in consensus morphological and dimensional changes and signal intensity alterations on images acquired in both positions, in different sequences and in different planes. In group A, MR imaging confirmed the diagnosis in 15/20 cases; in 4/15 cases, a partial tear of the plantar fascia was identified in the upright weight-bearing position alone. In the remaining 5/20 cases in group A and in all cases in group B, the plantar fascia showed no abnormal signal intensity. Because of the increased stretching of the plantar fascia, in all cases in group A and B, thickness in the proximal third was significantly reduced (p<0.0001) under upright weight-bearing compared with the supine position. Imaging the ankle/hind foot in the upright weight-bearing position with a dedicated MR scanner and a dedicated coil might enable the identification of partial tears of the plantar fascia, which could be overlooked in the supine position.
Hajiaghaei, Behnam; Ebrahimi, Ismail; Kamyab, Mojtaba; Saeedi, Hassan; Jalali, Maryam
2016-01-01
Creating a socket with proper fit is an important factor to ensure the comfort and control of prosthetic devices. Several techniques are commonly used to cast transtibial stumps but their effect on stump shape deformation is not well understood. This study compares the dimensions, circumferences and volumes of the positive casts and also the socket comfort between two casting methods. Our hypothesis was that the casts prepared by air pressure method have less volume and are more comfortable than those prepared by weight bearing method. Fifteen transtibial unilateral amputees participated in the study. Two weight bearing and air pressure casting methods were utilized for their residual limbs. The diameters and circumferences of various areas of the residual limbs and positive casts were compared. The volumes of two types of casts were measured by a volumeter and compared. Visual Analogue Scale (VAS) was used to measure the sockets fit comfort. Circumferences at 10 and 15 cm below the patella on the casts were significantly smaller in air pressure casting method compared to the weight bearing method (p=0.00 and 0.01 respectively). The volume of the cast in air pressure method was lower than that of the weight bearing method (p=0.006). The amputees found the fit of the sockets prepared by air pressure method more comfortable than the weight bearing sockets (p=0.015). The air pressure casting reduced the circumferences of the distal portion of residual limbs which has more soft tissue and because of its snug fit it provided more comfort for amputees, according to the VAS measurements.
Fault detection in rotor bearing systems using time frequency techniques
NASA Astrophysics Data System (ADS)
Chandra, N. Harish; Sekhar, A. S.
2016-05-01
Faults such as misalignment, rotor cracks and rotor to stator rub can exist collectively in rotor bearing systems. It is an important task for rotor dynamic personnel to monitor and detect faults in rotating machinery. In this paper, the rotor startup vibrations are utilized to solve the fault identification problem using time frequency techniques. Numerical simulations are performed through finite element analysis of the rotor bearing system with individual and collective combinations of faults as mentioned above. Three signal processing tools namely Short Time Fourier Transform (STFT), Continuous Wavelet Transform (CWT) and Hilbert Huang Transform (HHT) are compared to evaluate their detection performance. The effect of addition of Signal to Noise ratio (SNR) on three time frequency techniques is presented. The comparative study is focused towards detecting the least possible level of the fault induced and the computational time consumed. The computation time consumed by HHT is very less when compared to CWT based diagnosis. However, for noisy data CWT is more preferred over HHT. To identify fault characteristics using wavelets a procedure to adjust resolution of the mother wavelet is presented in detail. Experiments are conducted to obtain the run-up data of a rotor bearing setup for diagnosis of shaft misalignment and rotor stator rubbing faults.
Shi, Jingsheng; Chen, Jie; Wu, Jianguo; Chen, Feiyan; Huang, Gangyong; Wang, Zhan; Zhao, Guanglei; Wei, Yibing; Wang, Siqun
2014-01-01
Background The aim of this study was to contrast the collapse values of the postoperative weight-bearing areas of different tantalum rod implant positions, fibula implantation, and core decompression model and to investigate the advantages and disadvantages of tantalum rod implantation in different ranges of osteonecrosis in comparison with other methods. Material/Methods The 3D finite element method was used to establish the 3D finite element model of normal upper femur, 3D finite element model after tantalum rod implantation into different positions of the upper femur in different osteonecrosis ranges, and other 3D finite element models for simulating fibula implant and core decompression. Results The collapse values in the weight-bearing area of the femoral head of the tantalum rod implant model inside the osteonecrosis area, implant model in the middle of the osteonecrosis area, fibula implant model, and shortening implant model exhibited no statistically significant differences (p>0.05) when the osteonecrosis range was small (60°). The stress values on the artificial bone surface for the tantalum rod implant model inside the osteonecrosis area and the shortening implant model exhibited statistical significance (p<0.01). Conclusions Tantalum rod implantation into the osteonecrosis area can reduce the collapse values in the weight-bearing area when osteonecrosis of the femoral head (ONFH) was in a certain range, thereby obtaining better clinical effects. When ONFH was in a large range (120°), the tantalum rod implantation inside the osteonecrosis area, shortening implant or fibula implant can reduce the collapse values of the femoral head, as assessed by other methods. PMID:25479830
NASA Technical Reports Server (NTRS)
Simmons, D. J.; Winter, F.; Morey-Holton, E. R.
1984-01-01
The effect of a hypogravity simulating model on the rate of mandibular incisor formation, dentinogenesis and, amelogenesis in laboratory rats was studied. The model is the partial unloading by elevating the hindquarters. In this system, rat hindquarters are elevated 30 to 40 deg from the cage floors to completely unload the hindlimbs, but the animals are free to move about using their forelimbs. This model replicates the fluid sift changes which occur during the weightlessness of spaceflight and produces an osteopenia in the weight bearing skeletons. The histogenesis and/or mineralization rates of the mandibular incisor during the first 19d of PULEH in young growing rats are recorded.
Foot loading with an ankle-foot orthosis: the accuracy of an integrated physical strain trainer.
Pauser, Johannes; Jendrissek, Andreas; Brem, Matthias; Gelse, Kolja; Swoboda, Bernd; Carl, Hans-Dieter
2012-07-01
To investigate the value of a built-in physical strain trainer for the monitoring of partial weight bearing with an ankle-foot orthosis. 12 healthy volunteers were asked to perform three trials. Plantar peak pressure values from normal gait (trial one) were defined as 100% (baseline). The following trials were performed with the Vacoped® dynamic vacuum ankle orthosis worn in a neutral position with full weight bearing (trial two) and a restriction to 10% body weight (BW) (trial three), as monitored with an integrated physical strain trainer. Peak plantar pressure values were obtained using the pedar® X system. Peak pressure values were statistically significantly reduced wearing the Vacoped® shoe with full weight bearing for the hindfoot to 68% of the baseline (normal gait) and for the midfoot and forefoot to 83% and 60%, respectively. Limited weight bearing with 10% BW as controlled by physical strain trainer further reduced plantar peak pressure values for the hindfoot to 19%, for the midfoot to 43% of the baseline and the forefoot to 22% of the baseline. The Vacoped® vacuum ankle orthosis significantly reduces plantar peak pressure. The integrated physical strain trainer seems unsuitable to monitor a limitation to 10% BW adequately for the total foot. The concept of controlling partial weight bearing with the hindfoot-addressing device within the orthosis seems debatable but may be useful when the hindfoot in particular must be off-loaded.
Skeletal unloading induces selective resistance to the anabolic actions of growth hormone on bone
NASA Technical Reports Server (NTRS)
Halloran, B. P.; Bikle, D. D.; Harris, J.; Autry, C. P.; Currier, P. A.; Tanner, S.; Patterson-Buckendahl, P.; Morey-Holton, E.
1995-01-01
Loss of skeletal weight bearing or physical unloading of bone in the growing animal inhibits bone formation and induces a bone mineral deficit. To determine whether the inhibition of bone formation induced by skeletal unloading in the growing animal is a consequence of diminished sensitivity to growth hormone (GH) we studied the effects of skeletal unloading in young hypophysectomized rats treated with GH (0, 50, 500 micrograms/100 g body weight/day). Skeletal unloading reduced serum osteocalcin, impaired uptake of 3H-proline into bone, decreased proximal tibial mass, and diminished periosteal bone formation at the tibiofibular junction. When compared with animals receiving excipient alone, GH administration increased bone mass in all animals. The responses in serum osteocalcin, uptake of 3H-proline and 45Ca into the proximal tibia, and proximal tibial mass in non-weight bearing animals were equal to those in weight bearing animals. The responses in trabecular bone volume in the proximal tibia and bone formation at the tibiofibular junction to GH, however, were reduced significantly by skeletal unloading. Bone unloading prevented completely the increase in metaphyseal trabecular bone normally induced by GH and severely dampened the stimulatory effect (158% vs. 313%, p < 0.002) of GH on periosteal bone formation. These results suggest that while GH can stimulate the overall accumulation of bone mineral in both weight bearing and non-weight bearing animals, skeletal unloading selectively impairs the response of trabecular bone and periosteal bone formation to the anabolic actions of GH.
NASA Astrophysics Data System (ADS)
Shen, Fei; Chen, Chao; Yan, Ruqiang
2017-05-01
Classical bearing fault diagnosis methods, being designed according to one specific task, always pay attention to the effectiveness of extracted features and the final diagnostic performance. However, most of these approaches suffer from inefficiency when multiple tasks exist, especially in a real-time diagnostic scenario. A fault diagnosis method based on Non-negative Matrix Factorization (NMF) and Co-clustering strategy is proposed to overcome this limitation. Firstly, some high-dimensional matrixes are constructed using the Short-Time Fourier Transform (STFT) features, where the dimension of each matrix equals to the number of target tasks. Then, the NMF algorithm is carried out to obtain different components in each dimension direction through optimized matching, such as Euclidean distance and divergence distance. Finally, a Co-clustering technique based on information entropy is utilized to realize classification of each component. To verity the effectiveness of the proposed approach, a series of bearing data sets were analysed in this research. The tests indicated that although the diagnostic performance of single task is comparable to traditional clustering methods such as K-mean algorithm and Guassian Mixture Model, the accuracy and computational efficiency in multi-tasks fault diagnosis are improved.
Takagi, Shigeru; Sato, Takashi; Watanabe, Satoshi; Tanifuji, Osamu; Mochizuki, Tomoharu; Omori, Go; Endo, Naoto
2017-11-17
Abnormalities of lower extremity alignment (LEA) in recurrent patella dislocation (RPD) have been studied mostly by two-dimensional (2D) procedures leaving three-dimensional (3D) factors unknown. This study aimed to three-dimensionally examine risk factors for RPD in lower extremity alignment under the weight-bearing conditions. The alignment of 21 limbs in 15 RPD subjects was compared to the alignment of 24 limbs of 12 healthy young control subjects by an our previously reported 2D-3D image-matching technique. The sagittal, coronal, and transverse alignment in full extension as well as the torsional position of the femur (anteversion) and tibia (tibial torsion) under weight-bearing standing conditions were assessed by our previously reported 3D technique. The correlations between lower extremity alignment and RPD were assessed using multiple logistic regression analysis. The difference of lower extremity alignment in RPD between under the weight-bearing conditions and under the non-weight-bearing conditions was assessed. In the sagittal and coronal planes, there was no relationship (statistically or by clinically important difference) between lower extremity alignment angle and RPD. However, in the transverse plane, increased external tibial rotation [odds ratio (OR) 1.819; 95% confidence interval (CI) 1.282-2.581], increased femoral anteversion (OR 1.183; 95% CI 1.029-1.360), and increased external tibial torsion (OR 0.880; 95% CI 0.782-0.991) were all correlated with RPD. The tibia was more rotated relative to femur at the knee joint in the RPD group under the weight-bearing conditions compared to under the non-weight-bearing conditions (p < 0.05). This study showed that during weight-bearing, alignment parameters in the transverse plane related to the risk of RPD, while in the sagittal and coronal plane alignment parameters did not correlate with RPD. The clinical importance of this study is that the 3D measurements more directly, precisely, and sensitively detect rotational parameters associated with RPD and hence predict risk of RPD. III.
A kinetics database and scripts for PHREEQC
NASA Astrophysics Data System (ADS)
Hu, B.; Zhang, Y.; Teng, Y.; Zhu, C.
2017-12-01
Kinetics of geochemical reactions has been increasingly used in numerical models to simulate coupled flow, mass transport, and chemical reactions. However, the kinetic data are scattered in the literature. To assemble a kinetic dataset for a modeling project is an intimidating task for most. In order to facilitate the application of kinetics in geochemical modeling, we assembled kinetics parameters into a database for the geochemical simulation program, PHREEQC (version 3.0). Kinetics data were collected from the literature. Our database includes kinetic data for over 70 minerals. The rate equations are also programmed into scripts with the Basic language. Using the new kinetic database, we simulated reaction path during the albite dissolution process using various rate equations in the literature. The simulation results with three different rate equations gave difference reaction paths at different time scale. Another application involves a coupled reactive transport model simulating the advancement of an acid plume in an acid mine drainage site associated with Bear Creek Uranium tailings pond. Geochemical reactions including calcite, gypsum, and illite were simulated with PHREEQC using the new kinetic database. The simulation results successfully demonstrated the utility of new kinetic database.
Cooperative network clustering and task allocation for heterogeneous small satellite network
NASA Astrophysics Data System (ADS)
Qin, Jing
The research of small satellite has emerged as a hot topic in recent years because of its economical prospects and convenience in launching and design. Due to the size and energy constraints of small satellites, forming a small satellite network(SSN) in which all the satellites cooperate with each other to finish tasks is an efficient and effective way to utilize them. In this dissertation, I designed and evaluated a weight based dominating set clustering algorithm, which efficiently organizes the satellites into stable clusters. The traditional clustering algorithms of large monolithic satellite networks, such as formation flying and satellite swarm, are often limited on automatic formation of clusters. Therefore, a novel Distributed Weight based Dominating Set(DWDS) clustering algorithm is designed to address the clustering problems in the stochastically deployed SSNs. Considering the unique features of small satellites, this algorithm is able to form the clusters efficiently and stably. In this algorithm, satellites are separated into different groups according to their spatial characteristics. A minimum dominating set is chosen as the candidate cluster head set based on their weights, which is a weighted combination of residual energy and connection degree. Then the cluster heads admit new neighbors that accept their invitations into the cluster, until the maximum cluster size is reached. Evaluated by the simulation results, in a SSN with 200 to 800 nodes, the algorithm is able to efficiently cluster more than 90% of nodes in 3 seconds. The Deadline Based Resource Balancing (DBRB) task allocation algorithm is designed for efficient task allocations in heterogeneous LEO small satellite networks. In the task allocation process, the dispatcher needs to consider the deadlines of the tasks as well as the residue energy of different resources for best energy utilization. We assume the tasks adopt a Map-Reduce framework, in which a task can consist of multiple subtasks. The DBRB algorithm is deployed on the head node of a cluster. It gathers the status from each cluster member and calculates their Node Importance Factors (NIFs) from the carried resources, residue power and compute capacity. The algorithm calculates the number of concurrent subtasks based on the deadlines, and allocates the subtasks to the nodes according to their NIF values. The simulation results show that when cluster members carry multiple resources, resource are more balanced and rare resources serve longer in DBRB than in the Earliest Deadline First algorithm. We also show that the algorithm performs well in service isolation by serving multiple tasks with different deadlines. Moreover, the average task response time with various cluster size settings is well controlled within deadlines as well. Except non-realtime tasks, small satellites may execute realtime tasks as well. The location-dependent tasks, such as image capturing, data transmission and remote sensing tasks are realtime tasks that are required to be started / finished on specific time. The resource energy balancing algorithm for realtime and non-realtime mixed workload is developed to efficiently schedule the tasks for best system performance. It calculates the residue energy for each resource type and tries to preserve resources and node availability when distributing tasks. Non-realtime tasks can be preempted by realtime tasks to provide better QoS to realtime tasks. I compared the performance of proposed algorithm with a random-priority scheduling algorithm, with only realtime tasks, non-realtime tasks and mixed tasks. It shows the resource energy reservation algorithm outperforms the latter one with both balanced and imbalanced workloads. Although the resource energy balancing task allocation algorithm for mixed workload provides preemption mechanism for realtime tasks, realtime tasks can still fail due to resource exhaustion. For LEO small satellite flies around the earth on stable orbits, the location-dependent realtime tasks can be considered as periodical tasks. Therefore, it is possible to reserve energy for these realtime tasks. The resource energy reservation algorithm preserves energy for the realtime tasks when the execution routine of periodical realtime tasks is known. In order to reserve energy for tasks starting very early in each period that the node does not have enough energy charged, an energy wrapping mechanism is also designed to calculate the residue energy from the previous period. The simulation results show that without energy reservation, realtime task failure rate can reach more than 60% when the workload is highly imbalanced. In contrast, the resource energy reservation produces zero RT task failures and leads to equal or better aggregate system throughput than the non-reservation algorithm. The proposed algorithm also preserves more energy because it avoids task preemption. (Abstract shortened by ProQuest.).
An identification method for damping ratio in rotor systems
NASA Astrophysics Data System (ADS)
Wang, Weimin; Li, Qihang; Gao, Jinji; Yao, Jianfei; Allaire, Paul
2016-02-01
Centrifugal compressor testing with magnetic bearing excitations is the last step to assure the compressor rotordynamic stability in the designed operating conditions. To meet the challenges of stability evaluation, a new method combining the rational polynomials method (RPM) with the weighted instrumental variables (WIV) estimator to fit the directional frequency response function (dFRF) is presented. Numerical simulation results show that the method suggested in this paper can identify the damping ratio of the first forward and backward modes with high accuracy, even in a severe noise environment. Experimental tests were conducted to study the effect of different bearing configurations on the stability of rotor. Furthermore, two example centrifugal compressors (a nine-stage straight-through and a six-stage back-to-back) were employed to verify the feasibility of identification method in industrial configurations as well.
1980-10-01
AFAPL-TR-78-6 ’: Part Vill (U ROTOR -BEARING DYNAMICS - TECHNOLOGY DESIGN GUIDE ¢ Part Vil A Comput eri eval Syteftor Fluid Film Bearings SHAKER...Protection," Task 304806, "Aerospace Lubrication," Work Unit 30480685, " Rotor -Bearing Dynamics Design." The work reported herein was performed during the...the previous issue of the Rotor -Bearing Dynamics Technology Design Guide, - one volume dealt with the calculation of performance parameters and pertur
A New High-Speed Oil-Free Turbine Engine Rotordynamic Simulator Test Rig
NASA Technical Reports Server (NTRS)
Howard, Samuel A.
2007-01-01
A new test rig has been developed for simulating high-speed turbomachinery rotor systems using Oil-Free foil air bearing technology. Foil air bearings have been used in turbomachinery, primarily air cycle machines, for the past four decades to eliminate the need for oil lubrication. The goal of applying this bearing technology to other classes of turbomachinery has prompted the fabrication of this test rig. The facility gives bearing designers the capability to test potential bearing designs with shafts that simulate the rotating components of a target machine without the high cost of building "make-and-break" hardware. The data collected from this rig can be used to make design changes to the shaft and bearings in subsequent design iterations. This paper describes the new test rig and demonstrates its capabilities through the initial run with a simulated shaft system.
Upright CT of the knee: the effect of weight-bearing on joint alignment.
Hirschmann, Anna; Buck, Florian M; Fucentese, Sandro F; Pfirrmann, Christian W A
2015-11-01
To prospectively compare patellofemoral and femorotibial alignment in supine non-weight-bearing computed tomography (NWBCT) and upright weight-bearing CT (WBCT) and assess the differences in joint alignment. NWBCT and WBCT images of the knee were obtained in 26 patients (mean age, 57.0 ± 15.9 years; range, 21-81) using multiple detector CT for NWBCT and cone-beam extremity CT for WBCT. Two musculoskeletal radiologists independently quantified joint alignment by measuring femorotibial rotation, tibial tuberosity-trochlear groove distance (TTTG), lateral patellar tilt angle, lateral patellar shift, and medial and lateral femorotibial joint space widths. Significant differences between NWBCT and WBCT were sought using Wilcoxon signed-rank test (P-value < 0.05). Significant differences were found for femorotibial rotation (the NWBCT mean changed from 2.7° ± 5.1 (reader 1)/2.6° ± 5.6 (reader 2) external rotation to WBCT 0.4° ± 7.7/0.2° ± 7.5 internal rotation; P = 0.009/P = 0.004), TTTG (decrease from NWBCT (13.8 mm ± 5.1/13.9 mm ± 3.9) to WBCT (10.5 mm ± 5.0/10.9 mm ± 5.2; P = 0.008/P = 0.002), lateral patellar tilt angle (decrease from NWBCT (15.6° ± 6.7/16.9° ± 7.4) to WBCT (12.5° ± 7.7/15.0° ± 6.2; P = 0.011/P = 0.188). The medial femorotibial joint space decreased from NWBCT (3.9 mm ± 1.4/4.5 mm ± 1.3) to WBCT (2.9 mm ± 2.2/3.5 mm ± 2.2; P = 0.003/P = 0.004). Inter-reader agreement ranged from 0.52-0.97. Knee joint alignment changes significantly in the upright weight-bearing position using CT when compared to supine non-weight-bearing CT. • Cone-beam extremity CT offers upright weight-bearing examinations of the lower extremities. • Knee alignment changes significantly in an upright position compared to supine position. • Tibial tuberosity-trochlear groove distance (TTTG) is less pronounced in a weight-bearing position. • The weight-bearing position leads to a decrease of the lateral patellar tilt angle.
Measurement of the extreme ankle range of motion required by female ballet dancers.
Russell, Jeffrey A; Kruse, David W; Nevill, Alan M; Koutedakis, Yiannis; Wyon, Matthew A
2010-12-01
Female ballet dancers require extreme ankle motion, especially plantar flexion, but research about measuring such motion is lacking. The purposes of this study were to determine in a sample of ballet dancers whether non-weight-bearing ankle range of motion is significantly different from the weight-bearing equivalent and whether inclinometric plantar flexion measurement is a suitable substitute for standard plantar flexion goniometry. Fifteen female ballet dancers (5 university, 5 vocational, and 5 professional dancers; age 21 ± 3.0 years) volunteered. Subjects received 5 assessments on 1 ankle: non-weight-bearing goniometry dorsiflexion (NDF) and plantar flexion (NPF), weight-bearing goniometry in the ballet positions demi-plié (WDF) and en pointe (WPF), and non-weight-bearing plantar flexion inclinometry (IPF). Mean NDF was significantly lower than WDF (17° ± 1.3° vs 30° ± 1.8°, P < .001). NPF (77° ± 2.5°) was significantly lower than both WPF (83° ± 2.2°, P = .01) and IPF (89° ± 1.6°, P < .001), and WPF was significantly lower than IPF (P = .013). Dorsiflexion tended to decrease and plantar flexion tended to increase with increasing ballet proficiency. The authors conclude that assessment of extreme ankle motion in female ballet dancers is challenging, and goniometry and inclinometry appear to measure plantar flexion differently.
NASA Astrophysics Data System (ADS)
Nobis, M.; Stücke, P.; Schmidt, M.; Riedel, M.
2013-04-01
The laser-optical research of the flow inside the lubricating gap of a journal bearing model is one important task in a larger overall project. The long-term objective is the development of an easy-to-work calculation tool which delivers information about the causes and consequences of cavitation processes in hydrodynamically lubricated journal bearings. Hence, it will be possible to find statements for advantageous and disadvantageous geometrical shapes of the bushings. In conclusion such a calculation tool can provide important insights for the construction and design of future journal bearings. Current design programs are based on a two-dimensional approach for the lubricating gap. The first dimension is the breath of the bearing and the second dimension is the circumferential direction of the bearing. The third dimension, the expansion of the gap in radial direction, will be neglected. Instead of an exact resolution of the flow pattern inside the gap, turbulence models are in use. Past studies on numerical and experimental field have shown that inside the lubricating gap clearly organized and predominantly laminar flow structures can be found. Thus, for a detailed analysis of the reasons and effects of cavitation bubbles, a three-dimensional resolution of the lubricating gap is inevitable. In addition to the qualitative evaluation of the flow with visualization experiments it is possible to perform angle-based velocity measurements inside the gap with the help of a triggered Laser-Doppler- Velocimeter (LDV). The results of these measurements are used to validate three-dimensional CFD flow simulations, and to optimize the numerical mesh structure and the boundary conditions. This paper will present the experimental setup of the bearing model, some exemplary results of the visualization experiments and LDV measurements as well as a comparison between experimental and numerical results.
Garg, Arun; Moore, J Steven; Kapellusch, Jay M
2017-08-01
The Composite Strain Index (COSI) quantifies biomechanical stressors for complex tasks consisting of exertions at different force levels and/or with different exertion times. The Cumulative Strain Index (CUSI) further integrates biomechanical stressors from different tasks to quantify exposure for the entire work shift. The paper provides methodologies to compute COSI and CUSI along with examples. Complex task simulation produced 169,214 distinct tasks. Use of average, time-weighted average (TWA) and peak force and COSI classified 66.9, 28.2, 100 and 38.9% of tasks as hazardous, respectively. For job rotation the simulation produced 10,920 distinct jobs. TWA COSI, peak task COSI and CUSI classified 36.5, 78.1 and 66.6% jobs as hazardous, respectively. The results suggest that the TWA approach systematically underestimates the biomechanical stressors and peak approach overestimates biomechanical stressors, both at the task and job level. It is believed that the COSI and CUSI partially address these underestimations and overestimations of biomechanical stressors. Practitioner Summary: COSI quantifies exposure when applied hand force and/or duration of that force changes during a task cycle. CUSI integrates physical exposures from job rotation. These should be valuable tools for designing and analysing tasks and job rotation to determine risk of musculoskeletal injuries.
Safety assessment of a shallow foundation using the random finite element method
NASA Astrophysics Data System (ADS)
Zaskórski, Łukasz; Puła, Wojciech
2015-04-01
A complex structure of soil and its random character are reasons why soil modeling is a cumbersome task. Heterogeneity of soil has to be considered even within a homogenous layer of soil. Therefore an estimation of shear strength parameters of soil for the purposes of a geotechnical analysis causes many problems. In applicable standards (Eurocode 7) there is not presented any explicit method of an evaluation of characteristic values of soil parameters. Only general guidelines can be found how these values should be estimated. Hence many approaches of an assessment of characteristic values of soil parameters are presented in literature and can be applied in practice. In this paper, the reliability assessment of a shallow strip footing was conducted using a reliability index β. Therefore some approaches of an estimation of characteristic values of soil properties were compared by evaluating values of reliability index β which can be achieved by applying each of them. Method of Orr and Breysse, Duncan's method, Schneider's method, Schneider's method concerning influence of fluctuation scales and method included in Eurocode 7 were examined. Design values of the bearing capacity based on these approaches were referred to the stochastic bearing capacity estimated by the random finite element method (RFEM). Design values of the bearing capacity were conducted for various widths and depths of a foundation in conjunction with design approaches DA defined in Eurocode. RFEM was presented by Griffiths and Fenton (1993). It combines deterministic finite element method, random field theory and Monte Carlo simulations. Random field theory allows to consider a random character of soil parameters within a homogenous layer of soil. For this purpose a soil property is considered as a separate random variable in every element of a mesh in the finite element method with proper correlation structure between points of given area. RFEM was applied to estimate which theoretical probability distribution fits the empirical probability distribution of bearing capacity basing on 3000 realizations. Assessed probability distribution was applied to compute design values of the bearing capacity and related reliability indices β. Conducted analysis were carried out for a cohesion soil. Hence a friction angle and a cohesion were defined as a random parameters and characterized by two dimensional random fields. A friction angle was described by a bounded distribution as it differs within limited range. While a lognormal distribution was applied in case of a cohesion. Other properties - Young's modulus, Poisson's ratio and unit weight were assumed as deterministic values because they have negligible influence on the stochastic bearing capacity. Griffiths D. V., & Fenton G. A. (1993). Seepage beneath water retaining structures founded on spatially random soil. Géotechnique, 43(6), 577-587.
Engineering Design Handbook. Military Vehicle Power Plant Cooling
1975-06-01
ILTR BYASSCOOLING NOZZLES PRESSURE OI COLE OIL PUMP -TO ENGINE MAIN BEARINGS,BYPASS VALVE CONNECTING ROD BEARINGS. Is psi -ft-4 CAMSHAFT BEARINGS, I I...intended missions, tasks, and tree stumps, dust, and mud. Most vehicles functions under the conditions specified in have requirements for towing trailers
Effects of general principles of person transfer techniques on low back joint extension moment.
Katsuhira, Junji; Yamasaki, Syun; Yamamoto, Sumiko; Maruyama, Hitoshi
2010-01-01
The purpose of this study was to examine the effects of general principles of person transfer techniques specifically on the low back joint extension moment. These effects were examined by the following measurable quantitative parameters: 1) trunk bending angle, 2) knee flexion angle, 3) distance between the centers of gravity (COGs) of the caregiver and patient, representing the distance between the caregiver and patient, and 4) the vertical component of the ground reaction force representing the amount of the weight-bearing load on the caregiver's low back during transfers with and without assistive devices. Twenty students each took the role of caregiver, and one healthy adult simulated a patient. The participants performed three different transfer tasks: without any assistive device, with the patient wearing a low back belt, and with the caregiver using a transfer board. We found that the distance between the COGs and the vertical component of the ground reaction force, but not the trunk bending and knee flexion angles, were the variables that affected the low back joint extension moment. Our results suggest that the general principle of decreasing the distance between COGs is most effective for decreasing the low back joint extension moment during transfers under all conditions.
Hetherington-Rauth, Megan; Bea, Jennifer W; Blew, Robert M; Funk, Janet L; Hingle, Melanie D; Lee, Vinson R; Roe, Denise J; Wheeler, Mark D; Lohman, Timothy G; Going, Scott B
2018-05-22
With the high prevalence of childhood obesity, especially among Hispanic children, understanding how body weight and its components of lean and fat mass affect bone development is important, given that the amount of bone mineral accrued during childhood can determine osteoporosis risk later in life. The aim of this study was to assess the independent contributions of lean and fat mass on volumetric bone mineral density (vBMD), geometry, and strength in both weight-bearing and non-weight-bearing bones of Hispanic and non-Hispanic girls. Bone vBMD, geometry, and strength were assessed at the 20% distal femur, the 4% and 66% distal tibia, and the 66% distal radius of the non-dominant limb of 326, 9- to 12-year-old girls using peripheral quantitative computed tomography (pQCT). Total body lean and fat mass were measured by dual-energy x-ray absorptiometry (DXA). Multiple linear regression was used to assess the independent relationships of fat and lean mass with pQCT bone measures while adjusting for relevant confounders. Potential interactions between ethnicity and both fat and lean mass were also tested. Lean mass was a significant positive contributor to all bone outcomes (p < 0.05) with the exception of vBMD at diaphyseal sites. Fat mass was a significant contributor to bone strength at weight bearing sites, but did not significantly contribute to bone strength at the non-weight bearing radius and was negatively associated with radius cortical content and thickness. Bone measures did not significantly differ between Hispanic and non-Hispanic girls, although there was a significant interaction between ethnicity and fat mass with total bone area at the femur (p = 0.02) and 66% tibia (p = 0.005) as well as bone strength at the femur (p = 0.03). Lean mass is the main determinant of bone strength for appendicular skeletal sites. Fat mass contributes to bone strength in the weight-bearing skeleton but does not add to bone strength in non-weight-bearing locations and may potentially be detrimental. Bone vBMD, geometry, and strength did not differ between Hispanic and non-Hispanic girls; fat mass may be a stronger contributor to bone strength in weight-bearing bones of Hispanic girls compared to non-Hispanic. Copyright © 2018. Published by Elsevier Inc.
Osteoporosis. The Effects of Exercise Variables.
ERIC Educational Resources Information Center
Brodigan, Diane E.
1992-01-01
Reports a study of postmenopausal women's practice of exercise after age 30. Subjects (n=111) were studied with regard to their practice of weight-bearing, aerobic, regular, and area specific exercise. Findings indicated that regular practice (at least 90 minutes weekly) of weight-bearing, aerobic, and regular exercise affected the development of…
Berglund, Johan; Johansson, Henrik; Lundqvist, Mats; Cederström, Björn; Fredenberg, Erik
2014-01-01
Abstract. In x-ray imaging, contrast information content varies with photon energy. It is, therefore, possible to improve image quality by weighting photons according to energy. We have implemented and evaluated so-called energy weighting on a commercially available spectral photon-counting mammography system. The technique was evaluated using computer simulations, phantom experiments, and analysis of screening mammograms. The CNR benefit of energy weighting for a number of relevant target-background combinations measured by the three methods fell in the range of 2.2 to 5.2% when using optimal weight factors. This translates to a potential dose reduction at constant CNR in the range of 4.5 to 11%. We expect the choice of weight factor in practical implementations to be straightforward because (1) the CNR improvement was not very sensitive to weight, (2) the optimal weight was similar for all investigated target-background combinations, (3) aluminum/PMMA phantoms were found to represent clinically relevant tasks well, and (4) the optimal weight could be calculated directly from pixel values in phantom images. Reasonable agreement was found between the simulations and phantom measurements. Manual measurements on microcalcifications and automatic image analysis confirmed that the CNR improvement was detectable in energy-weighted screening mammograms. PMID:26158045
Mechanical response of the herniated human abdomen to the placement of different prostheses.
Hernández-Gascón, Belén; Peña, Estefanía; Grasa, Jorge; Pascual, Gemma; Bellón, Juan M; Calvo, Begoña
2013-05-01
This paper describes a method designed to model the repaired herniated human abdomen just after surgery and examine its static mechanical response to the maximum intra-abdominal pressure provoked by a physiological movement (standing cough). The model is based on the real geometry of the human abdomen bearing a large incisional hernia with several anatomical structures differentiated by MRI. To analyze the outcome of hernia repair, the surgical procedure was simulated by modeling a prosthesis placed over the hernia. Three surgical meshes with different mechanical properties were considered: an isotropic heavy-weight mesh (Surgipro®), a slightly anisotropic light-weight mesh (Optilene®), and a highly anisotropic medium-weight mesh (Infinit®). Our findings confirm that anisotropic implants need to be positioned such that the most compliant axis of the mesh coincides with the craneo-caudal direction of the body.
Kuntze, A; Kuntze, O
1991-02-01
For the control of scabies in tylopodes (L. bactrianus, L. guanicoe, L. glama) and brown bears 0.2 mg/kg body weight (1 ml/50 kg body weight) of Ivermectin subcutaneously injected proved to be remedy of choice. In Kodiak-bears the oral application of Ivomec-solution was effective against ascariasis, not, however, in polar bears. Sufficient effect was reached only once, whereas Equalan-paste proved to be highly effective. Despite of strong hygienic measures continous follow-up treatment for the prevention of re-invasion is indispensible.
Inaccuracy of a physical strain trainer for the monitoring of partial weight bearing.
Pauser, Johannes; Jendrissek, Andreas; Swoboda, Bernd; Gelse, Kolja; Carl, Hans-Dieter
2011-11-01
To investigate the use of a physical strain trainer for the monitoring of partial weight bearing. Case series with healthy volunteers. Orthopedic clinic. Healthy volunteers (N=10) with no history of foot complaints. Volunteers were taught to limit weight bearing to 10% body weight (BW) and 50% BW, monitored by a physical strain trainer. The parameters peak pressure, maximum force, force-time integral, and pressure-time integral were assessed by dynamic pedobarography when volunteers walked with full BW (condition 1), 50% BW (condition 2), and 10% BW (condition 3). With 10% BW (condition 3), forces with normative gait (condition 1) were statistically significantly reduced under the hindfoot where the physical strain trainer is placed. All pedobarographic parameters were, however, exceeded when the total foot was measured. A limitation to 10% BW with the physical strain trainer (condition 3) was equal to a bisection of peak pressure and maximum force for the total foot with normative gait (condition 1). Halved BW (condition 2) left a remaining mean 82% of peak pressure and mean 59% of maximum force from full BW (condition 1). The concept of controlling partial weight bearing with the hindfoot-addressing device does not represent complete foot loading. Such devices may be preferably applied in cases when the hindfoot in particular must be off-loaded. Other training devices (eg, biofeedback soles) that monitor forces of the total foot have to be used to control partial weight bearing of the lower limb accurately. Copyright © 2011 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Paul-Murphy, Joanne R.; Krugner-Higby, Lisa A.; Tourdot, Renee L.; Sladky, Kurt K.; Klauer, Julia M.; Keuler, Nicholas S.; Brown, Carolyn S.; Heath, Timothy D.
2014-01-01
Objective To evaluate injection of microcrystalline sodium urate (MSU) for inducing articular pain in green-cheeked conures (Pyrrhura molinae) and the analgesic efficacy of liposome-encapsulated butorphanol tartrate (LEBT) by use of weight load data, behavioral scores, and fecal corticosterone concentration. Animals 8 conures. Procedures In a crossover study, conures were randomly assigned to receive LEBT (15 mg/kg) or liposomal vehicle subsequent to experimental induction of arthritis or sham injection. The MSU was injected into 1 tibiotarsal-tarsometatarsal (intertarsal) joint to induce arthritis (time 0). Weight-bearing load and behavioral scores were determined at 0, 2, 6, 26, and 30 hours. Results MSU injection into 1 intertarsal joint caused a temporary decrease in weight bearing on the affected limb. Treatment of arthritic conures with LEBT resulted in significantly more weight bearing on the arthritic limb than treatment with vehicle. Administration of vehicle to arthritic conures caused a decrease in activity and feeding behaviors during the induction phase of arthritis, but as the arthritis resolved, there was a significant increase in voluntary activity at 30 hours and feeding behaviors at 26 and 30 hours, compared with results for LEBT treatment of arthritic birds. Treatment with LEBT or vehicle in conures without arthritis resulted in similar measurements for weight bearing and voluntary and motivated behaviors. Conclusions and Clinical Relevance Experimental induction of arthritis in conures was a good method for evaluating tonic pain. Weight-bearing load was the most sensitive measure of pain associated with induced arthritis. Pain associated with MSU-induced arthritis was alleviated by administration of LEBT. PMID:19795935
Inadequate thickness of the weight-bearing surface of claws in ruminants.
Shakespeare, A S
2009-12-01
The term 'thin soles' refers to the suboptimal thickness of the weight-bearing surface of claws in ruminants. These palmar/plantar surfaces of the claws support the weight of the animal and consist of the distal wall horn, the sole proper, the heel and the minute white line area. The sole should normally only bear weight on uneven or undulating surfaces. A decrease in the thickness of the weight-bearing claw surface will decrease the protective function of this structure and may alter the proportion of weight-bearing by each section with possible detrimental effects on hoof function. Horn tissue readily absorbs water and becomes softer which can lead to increased wear rates. Growth rates normally match wear rates but, unlike the latter, time is needed for the growth rate response to adapt to changes in wear rate. Concrete surfaces can be abrasive and dairy cows that spend their lactation cycle on these floors should be let out to pasture in the dry period so that their claws can recoup lost horn. Frictional coefficient is a measure of the'slipperiness' of hooves on various surfaces. Newly laid or fresh concrete is not only abrasive but the thin surface suspension of calcium hydroxide that forms has a very alkaline pH which causes keratin degradation and is mostly responsible for the excessive claw wear that occurs. Four case studies are used to illustrate the importance of the distal wall horn, the dangers of over-trimming and the effects of disease and concrete on horn growth and wear rates.
NASA Astrophysics Data System (ADS)
Seagroves, Scott; Harker, Justin; Laughlin, Gregory; Lacy, Justin; Castellano, Tim
2003-12-01
We describe a project (transitsearch.org) currently attempting to discover transiting intermediate-period planets orbiting bright parent stars, and we simulate that project's performance. The discovery of such a transit would be an important astronomical advance, bridging the critical gap in understanding between HD 209458b and Jupiter. However, the task is made difficult by intrinsically low transit probabilities and small transit duty cycles. This project's efficient and economical strategy is to photometrically monitor stars that are known (from radial velocity surveys) to bear planets, using a network of widely spaced observers with small telescopes. These observers, each individually capable of precision (1%) differential photometry, monitor candidates during the time windows in which the radial velocity solution predicts a transit if the orbital inclination is close to 90°. We use Monte Carlo techniques to simulate the performance of this network, performing simulations with different configurations of observers in order to optimize coordination of an actual campaign. Our results indicate that transitsearch.org can reliably rule out or detect planetary transits within the current catalog of known planet-bearing stars. A distributed network of skilled amateur astronomers and small college observatories is a cost-effective method for discovering the small number of transiting planets with periods in the range 10 days
Biofeedback device for patients on axillary crutches.
Ang, E J; Goh, J C; Bose, K; Toh, S L; Choo, A
1989-08-01
The axillary crutch is commonly prescribed as an ambulatory aid to patients with temporal or permanent disability in the lower extremity. When fitting the axillary crutch, it is important that the user be instructed not to bear excessive weight on the axillary bar. Excessive weight bearing on the axillary bar can result in a sevenfold increase in the reaction force under the armpit. This force may be a contributory factor to crutch paralysis or thrombosis of the axillobrachial artery. In order to prevent this occurrence an electronic biofeedback device was designed and developed for use in the training of 3-point swing-through axillary crutch ambulation. It detects excessive weight bearing on the axillary bar during crutch ambulation and produces an audible signal which prompts the patient to make necessary adjustment to relieve load bearing on the axillary bar. The design and development of the biofeedback device is discussed in this paper.
Situation awareness measures for simulated submarine track management.
Loft, Shayne; Bowden, Vanessa; Braithwaite, Janelle; Morrell, Daniel B; Huf, Samuel; Durso, Francis T
2015-03-01
The aim of this study was to examine whether the Situation Present Assessment Method (SPAM) and the Situation Awareness Global Assessment Technique (SAGAT) predict incremental variance in performance on a simulated submarine track management task and to measure the potential disruptive effect of these situation awareness (SA) measures. Submarine track managers use various displays to localize and track contacts detected by own-ship sensors. The measurement of SA is crucial for designing effective submarine display interfaces and training programs. Participants monitored a tactical display and sonar bearing-history display to track the cumulative behaviors of contacts in relationship to own-ship position and landmarks. SPAM (or SAGAT) and the Air Traffic Workload Input Technique (ATWIT) were administered during each scenario, and the NASA Task Load Index (NASA-TLX) and Situation Awareness Rating Technique were administered postscenario. SPAM and SAGAT predicted variance in performance after controlling for subjective measures of SA and workload, and SA for past information was a stronger predictor than SA for current/future information. The NASA-TLX predicted performance on some tasks. Only SAGAT predicted variance in performance on all three tasks but marginally increased subjective workload. SPAM, SAGAT, and the NASA-TLX can predict unique variance in submarine track management performance. SAGAT marginally increased subjective workload, but this increase did not lead to any performance decrement. Defense researchers have identified SPAM as an alternative to SAGAT because it would not require field exercises involving submarines to be paused. SPAM was not disruptive, but it is potentially problematic that SPAM did not predict variance in all three performance tasks. © 2014, Human Factors and Ergonomics Society.
An analysis of the 70-meter antenna hydrostatic bearing by means of computer simulation
NASA Technical Reports Server (NTRS)
Bartos, R. D.
1993-01-01
Recently, the computer program 'A Computer Solution for Hydrostatic Bearings with Variable Film Thickness,' used to design the hydrostatic bearing of the 70-meter antennas, was modified to improve the accuracy with which the program predicts the film height profile and oil pressure distribution between the hydrostatic bearing pad and the runner. This article presents a description of the modified computer program, the theory upon which the computer program computations are based, computer simulation results, and a discussion of the computer simulation results.
Development of a large support surface for an air-bearing type zero-gravity simulator
NASA Technical Reports Server (NTRS)
Glover, K. E.
1976-01-01
The methods used in producing a large, flat surface to serve as the supporting surface for an air-bearing type zero-gravity simulator using low clearance, thrust-pad type air bearings are described. Major problems encountered in the use of self-leveled epoxy coatings in this surface are discussed and techniques are recommended which proved effective in overcoming these problems. Performance requirements of the zero-gravity simulator vehicle which were pertinent to the specification of the air-bearing support surface are also discussed.
Influence of single hindlimb support during simulated weightlessness in the rat
NASA Technical Reports Server (NTRS)
Stump, Craig S.; Overton, J. Michael; Tipton, Charles M.
1990-01-01
A study was carried out to develop and evaluate a hindlimb suspension model, making it possible to differentiate the effects of non-weight bearing by hindlimbs per se from the systemic influence of simulated weightlessness. A support platform was designed which allowed the animal to maintain one hindlimb in a posture similar to the hindlimbs of the control animals at rest and to maintain one hindlimb in a posture similar to the hindlimbs of the control animals, providing a support for the animal to contract or stretch hindlimb muscles against at any time during suspension. The results of this study indicated that hindlimb support during head-down suspension will maintain muscle-mass/body-mass ratios, glycogen concentration, and blood flow. However, it will not prevent the loss in citrate synthase activity associated with conditions of simulated weightlessness.
Age, alcohol, and simulated altitude : effects on performance and breathalyzer scores.
DOT National Transportation Integrated Search
1988-01-01
Trained men in two groups, 30-39 (n=12) and 60-69 (n=13), each performed at the Multiple Task Performance Battery (MTPB) in four separate full-day sessions with and without alcohol (2.2 mL of 100-proof vodka per kg of body weight) at ground level and...
NASA Astrophysics Data System (ADS)
Rupcich, Franco John
The purpose of this study was to quantify the effectiveness of techniques intended to reduce dose to the breast during CT coronary angiography (CTCA) scans with respect to task-based image quality, and to evaluate the effectiveness of optimal energy weighting in improving contrast-to-noise ratio (CNR), and thus the potential for reducing breast dose, during energy-resolved dedicated breast CT. A database quantifying organ dose for several radiosensitive organs irradiated during CTCA, including the breast, was generated using Monte Carlo simulations. This database facilitates estimation of organ-specific dose deposited during CTCA protocols using arbitrary x-ray spectra or tube-current modulation schemes without the need to run Monte Carlo simulations. The database was used to estimate breast dose for simulated CT images acquired for a reference protocol and five protocols intended to reduce breast dose. For each protocol, the performance of two tasks (detection of signals with unknown locations) was compared over a range of breast dose levels using a task-based, signal-detectability metric: the estimator of the area under the exponential free-response relative operating characteristic curve, AFE. For large-diameter/medium-contrast signals, when maintaining equivalent AFE, the 80 kV partial, 80 kV, 120 kV partial, and 120 kV tube-current modulated protocols reduced breast dose by 85%, 81%, 18%, and 6%, respectively, while the shielded protocol increased breast dose by 68%. Results for the small-diameter/high-contrast signal followed similar trends, but with smaller magnitude of the percent changes in dose. The 80 kV protocols demonstrated the greatest reduction to breast dose, however, the subsequent increase in noise may be clinically unacceptable. Tube output for these protocols can be adjusted to achieve more desirable noise levels with lesser dose reduction. The improvement in CNR of optimally projection-based and image-based weighted images relative to photon-counting was investigated for six different energy bin combinations using a bench-top energy-resolving CT system with a cadmium zinc telluride (CZT) detector. The non-ideal spectral response reduced the CNR for the projection-based weighted images, while image-based weighting improved CNR for five out of the six investigated bin combinations, despite this non-ideal response, indicating potential for image-based weighting to reduce breast dose during dedicated breast CT.
Mobile-bearing knee systems: ultra-high molecular weight polyethylene wear and design issues.
Greenwald, A Seth; Heim, Christine S
2005-01-01
In June 2004, the U.S. Food and Drug Administration Orthopaedic Advisory Panel recommended the reclassification of mobile-bearing knee systems for general use. This reflects the increasing use of mobile-bearing knee systems internationally, which is currently limited in the United States by regulatory requirement. Mobile-bearing knee systems are distinguished from conventional, fixed-plateau systems in that they allow dual-surface articulation between an ultra-high molecular weight polyethylene insert and metallic femoral and tibial tray components. Their in vivo success is dependent on patient selection, design, and material choice, as well as surgical precision during implantation. Laboratory and clinical experience extending over 25 years with individual systems suggests that mobile-bearing knee systems represent a viable treatment option for patients with knee arthrosis.
Biodynamic feedback training to assure learning partial load bearing on forearm crutches.
Krause, Daniel; Wünnemann, Martin; Erlmann, Andre; Hölzchen, Timo; Mull, Melanie; Olivier, Norbert; Jöllenbeck, Thomas
2007-07-01
To examine how biodynamic feedback training affects the learning of prescribed partial load bearing (200N). Three pre-post experiments. Biomechanics laboratory in a German university. A volunteer sample of 98 uninjured subjects who had not used crutches recently. There were 24 subjects in experiment 1 (mean age, 23.2y); 64 in experiment 2 (mean age, 43.6y); and 10 in experiment 3 (mean age, 40.3y), parallelized by arm force. Video instruction and feedback training: In experiment 1, 2 varied instruction videos and reduced feedback frequency; in experiment 2, varied frequencies of changing tasks (contextual interference); and in experiment 3, feedback training (walking) and transfer (stair tasks). Vertical ground reaction force. Absolute error of practiced tasks was significantly reduced for all samples (P<.050). Varied contextual interference conditions did not significantly affect retention (P=.798) or transfer (P=.897). Positive transfer between tasks was significant in experiment 2 (P<.001) and was contrary to findings in experiment 3 (P=.071). Biodynamic feedback training is applicable for learning prescribed partial load bearing. The frequency of changing tasks is irrelevant. Despite some support for transfer effects, additional practice in climbing and descending stairs might be beneficial.
Kim, Jong-Hee; Thompson, LaDora V
2014-07-15
We tested the hypothesis that non-weight bearing-induced muscle weakness (i.e., specific force) results from decreases in myosin protein quantity (i.e., myosin content per half-sarcomere and the ratio of myosin to actin) and quality (i.e., force per half-sarcomere and population of myosin heads in the strong-binding state during muscle contraction) in single myosin heavy chain (MHC) type II fibers. Fisher-344 rats were assigned to weight-bearing control (Con) or non-weight bearing (NWB). The NWB rats were hindlimb unloaded for 2 wk. Diameter, force, and MHC content were determined in permeabilized single fibers from the semimembranosus muscle. MHC isoform and the ratio of MHC to actin in each fiber were determined by gel electrophoresis and silver staining techniques. The structural distribution of myosin from spin-labeled fiber bundles during maximal isometric contraction was evaluated using electron paramagnetic resonance spectroscopy. Specific force (peak force per cross-sectional area) in MHC type IIB and IIXB fibers from NWB was significantly reduced by 38% and 18%, respectively. MHC content per half-sarcomere was significantly reduced by 21%. Two weeks of hindlimb unloading resulted in a reduced force per half-sarcomere of 52% and fraction of myosin strong-binding during contraction of 34%. The results suggest that reduced myosin and actin content (quantity) and myosin quality concomitantly contribute to non-weight bearing-related muscle weakness. Copyright © 2014 the American Physiological Society.
French, Simone A; Story, Mary; Fulkerson, Jayne A; Himes, John H; Hannan, Peter; Neumark-Sztainer, Dianne; Ensrud, Kristine
2005-01-01
Background A two-year, community-based, group-randomized trial to promote bone mass gains among 9–11 year-old girls through increased intake of calcium-rich foods and weight-bearing physical activity was evaluated. Methods Following baseline data collection, 30 5th-grade Girl Scout troops were randomized to a two-year behavioral intervention program or to a no-treatment control group. Evaluations were conducted at baseline, one year, and two years. Measures included bone mineral content, density, and area (measured by DXA), dietary calcium intake (24-hour recall), and weight-bearing physical activity (physical activity checklist interview). Mixed-model regression was used to evaluate treatment-related changes in bone mineral content (g) for the total body, lumbar spine (L1-L4), proximal femur, one-third distal radius, and femoral neck. Changes in eating and physical activity behavioral outcomes were examined. Results Although the intervention was implemented with high fidelity, no significant intervention effects were observed for total bone mineral content or any specific bone sites. Significant intervention effects were observed for increases in dietary calcium. No significant intervention effects were observed for increases in weight-bearing physical activity. Conclusion Future research needs to identify the optimal dosage of weight-bearing physical activity and calcium-rich dietary behavior change required to maximize bone mass gains in pre-adolescent and adolescent girls. PMID:16029507
Superconducting Meissner Effect Bearings for Cryogenic Turbomachines
1993-05-01
Maximum 200 words) This report describes the second year efforts to develop a Meissner bearing system for miniature cryogenic turboexpanders used in... Turboexpander ....................................................................... 6 4.3. Task 7-Management and Reporting...The program is aimed at the development of a Meissner bearing system for miniature cryogenic turboexpanders used in Brayton cycle cryocoolers. "TIM
Polat, Gökhan; Karademir, Gökhan; Akalan, Ekin; Aşık, Mehmet; Erdil, Mehmet
2017-03-20
The aim of this study was to prospectively evaluate the compliance of our patients with a touchdown weight bearing (without supporting any weight on the affected side by only touching the plantar aspect of the foot to the ground to maintain balance to protect the affected side from mechanical loading) postoperative rehabilitation protocol after treatment of talar osteochondral lesion (TOL). Fourteen patients, who had been treated with arthroscopic debridement and microfracture, were followed prospectively. The patients were evaluated for weight bearing compliance with using a stationary gait analysis and feedback system at the postoperative first day, first week, third week, and sixth week. The mean visual analog scale (VAS) scores of the patients at the preoperative, postoperative first day, first week, third week, and sixth weeks were 5.5, 5.9, 3.6, 0.9, and 0.4, respectively. The decrease in VAS scores were statistically significant (p < 0.0001). First postoperative day revealed a mean value of transmitted weight of 4.08% ±0.8 (one non-compliant patient). The mean value was 4.34% ±0.8 at the first postoperative week (two non-compliant patients), 6.95% ±2.3 at the third postoperative week (eight non-compliant patients), and 10.8% ±4.8 at the sixth postoperative week (11 non-compliant patients). In the analysis of data, we found a negative correlation between VAS scores and transmitted weight (Kendall's tau b = -0.445 and p = 0.0228). Although patients were able to learn and adjust to the touchdown weight bearing gait protocol during the early postoperative period, most patients became non-compliant when their pain was relieved. To prevent this situation of non-compliance, patients should be warned to obey the weight bearing restrictions, and patients should be called for a follow-up at the third postoperative week.
Fault Detection of Roller-Bearings Using Signal Processing and Optimization Algorithms
Kwak, Dae-Ho; Lee, Dong-Han; Ahn, Jong-Hyo; Koh, Bong-Hwan
2014-01-01
This study presents a fault detection of roller bearings through signal processing and optimization techniques. After the occurrence of scratch-type defects on the inner race of bearings, variations of kurtosis values are investigated in terms of two different data processing techniques: minimum entropy deconvolution (MED), and the Teager-Kaiser Energy Operator (TKEO). MED and the TKEO are employed to qualitatively enhance the discrimination of defect-induced repeating peaks on bearing vibration data with measurement noise. Given the perspective of the execution sequence of MED and the TKEO, the study found that the kurtosis sensitivity towards a defect on bearings could be highly improved. Also, the vibration signal from both healthy and damaged bearings is decomposed into multiple intrinsic mode functions (IMFs), through empirical mode decomposition (EMD). The weight vectors of IMFs become design variables for a genetic algorithm (GA). The weights of each IMF can be optimized through the genetic algorithm, to enhance the sensitivity of kurtosis on damaged bearing signals. Experimental results show that the EMD-GA approach successfully improved the resolution of detectability between a roller bearing with defect, and an intact system. PMID:24368701
Shalumon, K T; Jayabalan, M
2009-12-01
Biodegradation of crosslinked-hydroxy terminated-poly(proplyene fumarate) (X-HTPPF) has been studied in simulated physiological media to assess the formation of porous scaffold structure for bone growth and remodeling in load bearing orthopedic applications. Variation in crosslink density and surface hydrophilicity of X-HTPPF are observed due to non-stoichiometric mass of reacting partners. These variations influence absorption of the medium and biodegradation during aging. Though the initial absorption of medium is relatively higher with the crosslinked polymer (PNVP1) having 63.6% HT-PPF and 36.4% comonomer n-vinyl pyrrolidone (NVP) during the initial period of aging, the weight loss due to subsequent degradation with time is relatively lesser. PNVP1 undergo slow degradation with formation of fibril structure on the surface. The present crosslinked material PNVP1 is a candidate for the load bearing orthopedic applications.
Research Capabilities for Oil-Free Turbomachinery Expanded by New Rotordynamic Simulator Facility
NASA Technical Reports Server (NTRS)
Howard, Samuel A.
2004-01-01
A new test rig has been developed for simulating high-speed turbomachinery shafting using Oil-Free foil air bearing technology. Foil air journal bearings are self-acting hydrodynamic bearings with a flexible inner sleeve surface using air as the lubricant. These bearings have been used in turbomachinery, primarily air cycle machines, for the past four decades to eliminate the need for oil lubrication. More recently, interest has been growing in applying foil bearings to aircraft gas turbine engines. They offer potential improvements in efficiency and power density, decreased maintenance costs, and other secondary benefits. The goal of applying foil air bearings to aircraft gas turbine engines prompted the fabrication of this test rig. The facility enables bearing designers to test potential bearing designs with shafts that simulate the rotating components of a target engine without the high cost of building actual flight hardware. The data collected from this rig can be used to make changes to the shaft and bearings in subsequent design iterations. The rest of this article describes the new test rig and demonstrates some of its capabilities with an initial simulated shaft system. The test rig has two support structures, each housing a foil air journal bearing. The structures are designed to accept any size foil journal bearing smaller than 63 mm (2.5 in.) in diameter. The bearing support structures are mounted to a 91- by 152-cm (3- by 5-ft) table and can be separated by as much as 122 cm (4 ft) and as little as 20 cm (8 in.) to accommodate a wide range of shaft sizes. In the initial configuration, a 9.5-cm (3.75-in.) impulse air turbine drives the test shaft. The impulse turbine, as well as virtually any number of "dummy" compressor and turbine disks, can be mounted on the shaft inboard or outboard of the bearings. This flexibility allows researchers to simulate various engine shaft configurations. The bearing support structures include a unique bearing mounting fixture that rotates to accommodate a laserbased alignment system. This can measure the misalignment of the bearing centers in each of 2 translational degrees of freedom and 2 rotational degrees of freedom. In the initial configuration, with roughly a 30.5-cm- (12-in.-) long shaft, two simulated aerocomponent disks, and two 50.8-cm (2-in.) foil journal bearings, the rig can operate at 65,000 rpm at room temperature. The test facility can measure shaft displacements in both the vertical and horizontal directions at each bearing location. Horizontal and vertical structural vibrations are monitored using accelerometers mounted on the bearing support structures. This information is used to determine system rotordynamic response, including critical speeds, mode shapes, orbit size and shape, and potentially the onset of instabilities. Bearing torque can be monitored as well to predict the power loss in the foil bearings. All of this information is fed back and forth between NASA and the foil bearing designers in an iterative fashion to converge on a final bearing and shaft design for a given engine application. In addition to its application development capabilities, the test rig offers several unique capabilities for basic bearing research. Using the laser alignment system mentioned earlier, the facility will be used to map foil air journal bearing performance. A known misalignment of increasing severity will be induced to determine the sensitivity of foil bearings to misalignment. Other future plans include oil-free integral starter generator testing and development, and dynamic load testing of foil journal bearings.
A wearable navigation display can improve attentiveness to the surgical field.
Stewart, James; Billinghurst, Mark
2016-06-01
Surgical navigation is typically shown on a computer display that is distant from the patient, making it difficult for the surgeon to watch the patient while performing a guided task. We investigate whether a light-weight, untracked, wearable display (such as Google Glass, which has the same size and weight as corrective glasses) can improve attentiveness to the surgical field in a simulated surgical task. Three displays were tested: a computer monitor; a peripheral display above the eye; and a through-the-lens display in front of the eye. Twelve subjects performed a task to position and orient a tracked tool on a plastic femur. Both wearable displays were tested on the dominant and non-dominant eyes of each subject. Attentiveness during the task was measured by the time taken to respond to randomly illuminated LEDs on the femur. Attentiveness was improved with the wearable displays at the cost of a decrease in accuracy. The through-the-lens display performed better than the peripheral display. The peripheral display performed better when on the dominant eye, while the through-the-lens display performed better when on the non-dominant eye. Attentiveness to the surgical field can be improved with the use of a light-weight, untracked, wearable display. A through-the-lens display performs better than a peripheral display, and both perform better than a computer monitor. Eye dominance should be considered when positioning the display.
Lee, Dong-Kyu; An, Duk-Hyun; Yoo, Won-Gyu; Hwang, Byong-Yong; Kim, Tae-Ho; Oh, Jae-Seop
2017-05-01
Neural reorganization for movement therapy after a stroke is thought to be an important mechanism that facilitates motor recovery. However, there is a lack of evidence for the effectiveness of exercise programs in improving the lower limbs. We investigated the immediate effect of isolating the paretic limb using different foot positions ((i) foot parallel; both feet parallel, (ii) foot asymmetry; paretic foot backward by 10 cm, and (iii) foot lifting; nonparetic foot lifting by normalization to 25% of knee height) on weight-bearing distribution and electromyography (EMG) of the thigh muscle during squats. In total, 20 patients with hemiplegia and 16 healthy subjects randomly performed three squat conditions in which the knee joint was flexed to 30°. Weight distribution was measured using the BioRescue system. Muscle activity was measured using a surface EMG system. Patients with hemiplegia exhibited significantly decreased weight bearing on the paretic foot at 0° and 30° knee flexion compared with the nondominant foot of a healthy subject. The muscle activity of the quadriceps was significantly lower in patients with hemiplegia compared to healthy subjects. Weight bearing and EMG activity of the quadriceps femoris on the paretic or nondominant side significantly increased during a knee flexion of 30° with under the foot asymmetry and foot lifting positions compared with the parallel foot position. Isolating the paretic limb using the asymmetric foot positions and lifting of the foot during squats might help patients with hemiplegia to improve weight-bearing and achieve greater activation of the quadriceps muscle in the paretic limb.
ERIC Educational Resources Information Center
Terrio, Kate; Auld, Garry W.
2002-01-01
Determined the extent and integration of osteoporosis knowledge in three age groups of women, comparing knowledge to calcium intake and weight bearing physical activity (WBPA). Overall calcium intake was relatively high. There were no differences in knowledge, calcium intake, or WBPA by age, nor did knowledge predict calcium intake and WBPA. None…
Henning, Troy; Lueders, Daniel; Chang, Kate; Yang, Lynda
2018-03-06
The prevalence of carpal tunnel syndrome (CTS) in patients with postpolio syndrome occurs at a rate of 22%. Irrespective of those with CTS, 74% of postpolio patients weight bear through their arms for ambulation or transfers. As open carpal tunnel release is performed along the weight-bearing region of the wrist, their functional independence may be altered while recovering. This case demonstrates that ultrasound-guided carpal tunnel release was successfully performed in a patient with postpolio syndrome allowing him to immediately weight bear through his hands after the procedure so he could recover at home. Copyright © 2018 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.
Load-bearing capacity of all-ceramic posterior inlay-retained fixed dental prostheses.
Puschmann, Djamila; Wolfart, Stefan; Ludwig, Klaus; Kern, Matthias
2009-06-01
The purpose of this in vitro study was to compare the quasi-static load-bearing capacity of all-ceramic resin-bonded three-unit inlay-retained fixed dental prostheses (IRFDPs) made from computer-aided design/computer-aided manufacturing (CAD/CAM)-manufactured yttria-stabilized tetragonal zirconia polycrystals (Y-TZP) frameworks with two different connector dimensions, with and without fatigue loading. Twelve IRFDPs each were made with connector dimensions 3 x 3 mm(2) (width x height) (control group) and 3 x 2 mm(2) (test group). Inlay-retained fixed dental prostheses were adhesively cemented on identical metal-models using composite resin cement. Subgroups of six specimens each were fatigued with maximal 1,200,000 loading cycles in a chewing simulator with a weight load of 25 kg and a load frequency of 1.5 Hz. The load-bearing capacity was tested in a universal testing machine for IRFDPs without fatigue loading and for IRFDPs that had not already fractured during fatigue loading. During fatigue testing one IRFDP (17%) of the test group failed. Under both loading conditions, IRFDPs of the control group exhibited statistically significantly higher load-bearing capacities than the test group. Fatigue loading reduced the load-bearing capacity in both groups. Considering the maximum chewing forces in the molar region, it seems possible to use zirconia ceramic as a core material for IRFDPs with a minimum connector dimension of 9 mm(2). A further reduction of the connector dimensions to 6 mm(2) results in a significant reduction of the load-bearing capacity.
Review of LOX Bearing and Seal Materials Tester (BSMT) radial load system
NASA Technical Reports Server (NTRS)
Dufrane, K. F.; Kannel, J. W.
1984-01-01
Problems concerning the bearings in the high pressure oxygen turbopumps (HPOTP) were investigated. The tasks involved: failure analyses, bearing dynamics calculations, lubrication studies, wear studies, and analyses of thermal transients. The radial load system on MSFC's bearing and seal tester used to study components for the HPOTP in liquid oxygen (LOX) is analyzed and the wear behavior of AISI 440C steel with polytetrafluoroethylene (PTFE) lubrication is studied.
Objective Model Selection for Identifying the Human Feedforward Response in Manual Control.
Drop, Frank M; Pool, Daan M; van Paassen, Marinus Rene M; Mulder, Max; Bulthoff, Heinrich H
2018-01-01
Realistic manual control tasks typically involve predictable target signals and random disturbances. The human controller (HC) is hypothesized to use a feedforward control strategy for target-following, in addition to feedback control for disturbance-rejection. Little is known about human feedforward control, partly because common system identification methods have difficulty in identifying whether, and (if so) how, the HC applies a feedforward strategy. In this paper, an identification procedure is presented that aims at an objective model selection for identifying the human feedforward response, using linear time-invariant autoregressive with exogenous input models. A new model selection criterion is proposed to decide on the model order (number of parameters) and the presence of feedforward in addition to feedback. For a range of typical control tasks, it is shown by means of Monte Carlo computer simulations that the classical Bayesian information criterion (BIC) leads to selecting models that contain a feedforward path from data generated by a pure feedback model: "false-positive" feedforward detection. To eliminate these false-positives, the modified BIC includes an additional penalty on model complexity. The appropriate weighting is found through computer simulations with a hypothesized HC model prior to performing a tracking experiment. Experimental human-in-the-loop data will be considered in future work. With appropriate weighting, the method correctly identifies the HC dynamics in a wide range of control tasks, without false-positive results.
Trunk extensor muscle fatigue influences trunk muscle activities.
Hoseinpoor, Tahere Seyed; Kahrizi, Sedighe; Mobini, Bahram
2015-01-01
Trunk muscles fatigue is one of the risk factors in workplaces and daily activities. Loads would be redistributed among active and passive tissues in a non-optimal manner in fatigue conditions. Therefore, a single tissue might be overloaded with minimal loads and as a result the risk of injury would increase. The goal of this paper was to assess the electromyographic response of trunk extensor and abdominal muscles after trunk extensor muscles fatigue induced by cyclic lifting task. This was an experimental study that twenty healthy women participated. For assessing automatic response of trunk extensor and abdominal muscles before and after the fatigue task, electromyographic activities of 6 muscles: thorasic erector spine (TES), lumbar erector spine (LES), lumbar multifidus (LMF), transverse abdominis/ internal oblique (TrA/IO), rectus abdominis (RA) and external oblique (EO) were recorded in standing position with no load and symmetric axial loads equal to 25% of their body weights. Statistical analysis showed that all the abdominal muscles activity decreased with axial loads after performing fatigue task but trunk extensor activity remained constant. Results of the current study indicated that muscle recruitment strategies changed with muscle fatigue and load bearing, therefore risks of tissue injury may increase in fatigue conditions.
The effect of chronic mild stress on tumor-bearing rats' behavior and its mechanism.
Xiu, Li-Juan; Lin, Hui-Ming; Wei, Pin-Kang
2010-03-31
Much evidence has demonstrated that stress and tumor interact, but the mechanisms are poorly understood. The purpose of this study is to discuss the effect of unpredictable chronic mild stress (CMS) upon the behavior of Walker 256 tumor-bearing rats and its mechanism. Observe the effects of CMS on the sucrose consumption, activities, body weight and levels of serums TNF-alpha and IL-6 of both tumor-bearing rats and non-tumor-bearing rats, and on the levels of Bcl-2 and the phosphor-ERK1/2 in their hippocampus. CMS can reduce the average sucrose consumption, behavioral scores, body weight gain, expression of Bcl-2 and p-ERK1/2 protein in hippocampus, and increase serums TNF-alpha and IL-6 of both tumor-bearing rats and non-tumor-bearing rats. The stressed tumor-bearing rats had less sucrose consumption, body weight gain and lower behavioral scores, but higher level of serum TNF-alpha than stressed non-tumor-bearing rats. A negative correlation was found between the levels of serum TNF-alpha and sucrose consumption, while a positive correlation between the expression of Bcl-2 protein in hippocampus proper and sucrose consumption. CMS can reduce the protein levels of Bcl-2 and p-ERK1/2 in the rats' hippocampus, which contributes to the changes in the rats' behavior caused by CMS. Tumor-bearing rats are prone to behave depressively after the exposure to CMS. Our findings have suggested that the tumor, by increasing the inflammatory reaction, can be taken as a stressor, affecting the hippocampus and consequently causing depression by decreasing the expression of Bcl-2 and p-ERK1/2 in hippocampus. Copyright 2009 Elsevier Ireland Ltd. All rights reserved.
Orbit transfer vehicle engine technology program. Task B-6 high speed turbopump bearings
NASA Technical Reports Server (NTRS)
1992-01-01
Bearing types were evaluated for use on the Orbit Transfer Vehicle (OTV) high pressure fuel pump. The high speed, high load, and long bearing life requirements dictated selection of hydrostatic bearings as the logical candidate for this engine. Design and fabrication of a bearing tester to evaluate these cryogenic hydrostatic bearings was then conducted. Detailed analysis, evaluation of bearing materials, and design of the hydrostatic bearings were completed resulting in fabrication of Carbon P5N and Kentanium hydrostatic bearings. Rotordynamic analyses determined the exact bearing geometry chosen. Instrumentation was evaluated and data acquisition methods were determined for monitoring shaft motion up to speeds in excess of 200,000 RPM in a cryogenic atmosphere. Fabrication of all hardware was completed, but assembly and testing was conducted outside of this contract.
Analysis of spatial thermal field in a magnetic bearing
NASA Astrophysics Data System (ADS)
Wajnert, Dawid; Tomczuk, Bronisław
2018-03-01
This paper presents two mathematical models for temperature field analysis in a new hybrid magnetic bearing. Temperature distributions have been calculated using a three dimensional simulation and a two dimensional one. A physical model for temperature testing in the magnetic bearing has been developed. Some results obtained from computer simulations were compared with measurements.
Meireles, S; De Groote, F; Van Rossom, S; Verschueren, S; Jonkers, I
2017-03-01
This study, firstly, investigates the effect of using an anatomical versus a functional axis of rotation (FAR) on knee adduction moment (KAM) in healthy subjects and patients with knee osteoarthritis (KOA). Secondly, this study reports KAM for models with FAR calculated using weight-bearing and non-weight-bearing motion. Three musculoskeletal models were created using OpenSim with different knee axis of rotation (AR): transepicondylar axis (TEA); FAR calculated based on SARA algorithm using a weight-bearing motion (wFAR) and a non-weight-bearing motion (nwFAR). KAM were calculated during gait in fifty-nine subjects (n=20 healthy, n=16 early OA, n=23 established OA) for all models and groups. Significant differences between the three groups in the first peak KAM were found when TEA was used (p=0.038). However, these differences were no longer present when using FAR. In subjects with established OA, KAMs were significantly reduced when using nwFAR compared to TEA models but also compared to wFAR models. The presence of excessive KAM in subjects with established KOA showed to be dependent on the definition of the AR: anatomical versus functional. Therefore, caution should be accounted when comparing KAM in different studies on KOA patients. In patients with end-stage knee OA where increased passive knee laxity is likely to exist, the use of weight-bearing motions should be considered to avoid increased variability in the location and orientation of a FAR obtained from activities with only limited joint loading. Copyright © 2017 Elsevier B.V. All rights reserved.
Parisi, Maria Candida Ribeiro; Godoy-Santos, Alexandre Leme; Ortiz, Rafael Trevisan; Sposeto, Rafael Barban; Sakaki, Marcos Hideyo; Nery, Marcia; Fernandes, Tulio Diniz
2013-01-01
One of the most common gold standards for the treatment of Charcot neuroarthropathy (CN) in the early Eichenholtz stages I and II is immobilization with the total contact casting and lower limb offloading. However, the total amount of offloading is still debatable. This study evaluates the clinical and radiographic findings in the treatment of early stages of CN (Eichenholtz stages I and II) with a walker boot and immediate total weight-bearing status. Twenty-two patients with type 2 diabetes mellitus (DM) and CN of Eichenholtz stages I and II were selected for non-operative treatment. All patients were educated about their condition, and full weight bearing was allowed as tolerated. Patients were monitored on a fortnightly basis in the earlier stages, with clinical examination, temperature measurement, and standardized weight-bearing radiographs. Their American Orthopedic Foot and Ankle Society (AOFAS) scores were determined before and after the treatment protocol. No cutaneous ulcerations or infections were observed in the evaluated cases. The mean measured angles at the beginning and end of the study, although showing relative increase, did not present a statistically significant difference (p > 0.05). Mean AOFAS scores showed a statistically significant improvement by the end of the study (p < 0.005). The treatment of early stages of CN (Eichenholtz stages I and II) with emphasis on walker boot and immediate weight bearing has shown a good functional outcome, non-progressive deformity on radiographic assessment, and promising results as a safe treatment option.
Bae, Dae Kyung; Lee, Jong Whan; Cho, Seong Jin; Song, Sang Jun
2017-01-01
Purpose To compare navigation and weight bearing radiographic measurements of mechanical axis (MA) before and after closed wedge high tibial osteotomy (HTO) and to evaluate post-osteotomy changes in MA assessed during application of external varus or valgus force. Materials and Methods Data from 30 consecutive patients (30 knees) who underwent computer-assisted closed-wedge HTO were prospectively analyzed. Pre- and postoperative weight bearing radiographic evaluation of MA was performed. Under navigation guidance, pre- and post-osteotomy MA values were measured in an unloaded position. Any change in the post-osteotomy MA in response to external varus or valgus force, which was named as dynamic range, was evaluated with the navigation system. The navigation and weight bearing radiographic measurements were compared. Results Although there was a positive correlation between navigation and radiographic measurements, the reliability of navigation measurements of coronal alignment was reduced after osteotomy and wedge closing. The mean post-osteotomy MA value measured with the navigation was 3.5°±0.8° valgus in an unloaded position. It was 1.3°±0.8° valgus under varus force and 5.8°±1.1° valgus under valgus force. The average dynamic range was >±2°. Conclusions Potential differences between the postoperative MAs assessed by weight bearing radiographs and the navigation system in unloaded position should be considered during computer-assisted closed wedge HTO. Care should be taken to keep the dynamic range within the permissible range of alignment goal in HTO. PMID:28854769
NASA Technical Reports Server (NTRS)
Lawen, James L., Jr.; Flowers, George T.
1995-01-01
This study examines the response of a flexible rotor supported by load sharing between linear bearings and an auxiliary clearance bearing. The objective is to develop a better understanding of the dynamical behavior of a magnetic bearing supported rotor system interacting with auxiliary bearings during a critical operating condition. Of particular interest is the effect of coupling between the bearing/housing and shaft vibration on the rotordynamical responses. A simulation model is developed and a number of studies are performed for various parametric configurations. An experimental investigation is also conducted to compare and verify the rotordynamic behavior predicted by the simulation studies. A strategy for reducing synchronous shaft vibration through appropriate design of coupled shaft/bearing/housing vibration modes is identified.
NASA Astrophysics Data System (ADS)
Liao, Yuhe; Sun, Peng; Wang, Baoxiang; Qu, Lei
2018-05-01
The appearance of repetitive transients in a vibration signal is one typical feature of faulty rolling element bearings. However, accurate extraction of these fault-related characteristic components has always been a challenging task, especially when there is interference from large amplitude impulsive noises. A frequency domain multipoint kurtosis (FDMK)-based fault diagnosis method is proposed in this paper. The multipoint kurtosis is redefined in the frequency domain and the computational accuracy is improved. An envelope autocorrelation function is also presented to estimate the fault characteristic frequency, which is used to set the frequency hunting zone of the FDMK. Then, the FDMK, instead of kurtosis, is utilized to generate a fast kurtogram and only the optimal band with maximum FDMK value is selected for envelope analysis. Negative interference from both large amplitude impulsive noise and shaft rotational speed related harmonic components are therefore greatly reduced. The analysis results of simulation and experimental data verify the capability and feasibility of this FDMK-based method
Embedding Task-Based Neural Models into a Connectome-Based Model of the Cerebral Cortex.
Ulloa, Antonio; Horwitz, Barry
2016-01-01
A number of recent efforts have used large-scale, biologically realistic, neural models to help understand the neural basis for the patterns of activity observed in both resting state and task-related functional neural imaging data. An example of the former is The Virtual Brain (TVB) software platform, which allows one to apply large-scale neural modeling in a whole brain framework. TVB provides a set of structural connectomes of the human cerebral cortex, a collection of neural processing units for each connectome node, and various forward models that can convert simulated neural activity into a variety of functional brain imaging signals. In this paper, we demonstrate how to embed a previously or newly constructed task-based large-scale neural model into the TVB platform. We tested our method on a previously constructed large-scale neural model (LSNM) of visual object processing that consisted of interconnected neural populations that represent, primary and secondary visual, inferotemporal, and prefrontal cortex. Some neural elements in the original model were "non-task-specific" (NS) neurons that served as noise generators to "task-specific" neurons that processed shapes during a delayed match-to-sample (DMS) task. We replaced the NS neurons with an anatomical TVB connectome model of the cerebral cortex comprising 998 regions of interest interconnected by white matter fiber tract weights. We embedded our LSNM of visual object processing into corresponding nodes within the TVB connectome. Reciprocal connections between TVB nodes and our task-based modules were included in this framework. We ran visual object processing simulations and showed that the TVB simulator successfully replaced the noise generation originally provided by NS neurons; i.e., the DMS tasks performed with the hybrid LSNM/TVB simulator generated equivalent neural and fMRI activity to that of the original task-based models. Additionally, we found partial agreement between the functional connectivities using the hybrid LSNM/TVB model and the original LSNM. Our framework thus presents a way to embed task-based neural models into the TVB platform, enabling a better comparison between empirical and computational data, which in turn can lead to a better understanding of how interacting neural populations give rise to human cognitive behaviors.
Quantifying weight bearing while in passive standers and a comparison of standers.
Kecskemethy, Heidi H; Herman, Daniel; May, Ryan; Paul, Kathleen; Bachrach, Steven J; Henderson, Richard C
2008-07-01
Mechanical loading plays an important role in skeletal health, and this is a major reason standing devices are widely used with non-ambulatory persons. However, little is known about the true axial loading that occurs while in a stander, or the factors which may impact loading. The purpose of this study was to quantify weight borne while in a stander, and to directly compare different standers. Load measuring footplate adaptors were designed and fabricated specifically for this study. Weight bearing loads in 20 non-ambulatory persons with quadriplegic cerebral palsy aged 6 to 21 years (median 14 y) were continuously monitored during routine 30-minute standing sessions. Fourteen participants were female, six were male; one was Gross Motor Function Classification System (GMFCS) Level IV, and 19 were GMFCS Level V. Each participant was monitored on four to six occasions over an 8-week period, two to three times in each of two different standers (total 108 standing sessions). Weight bearing loads ranged widely from 37 to 101% of body weight. The difference between standers was as much as 29% body weight. There is wide variance in the actual weight borne while in passive standers. The type of stander utilized is one factor which can significantly affect the amount of weight borne.
Ellman, Rachel; Spatz, Jordan; Cloutier, Alison; Palme, Rupert; Christiansen, Blaine A; Bouxsein, Mary L
2014-01-01
Although the musculoskeletal system is known to be sensitive to changes in its mechanical environment, the relationship between functional adaptation and below-normal mechanical stimuli is not well defined. We investigated bone and muscle adaptation to a range of reduced loading using the partial weight suspension (PWS) system, in which a two-point harness is used to offload a tunable amount of body weight while maintaining quadrupedal locomotion. Skeletally mature female C57Bl/6 mice were exposed to partial weight bearing at 20%, 40%, 70%, or 100% of body weight for 21 days. A hindlimb unloaded (HLU) group was included for comparison in addition to age-matched controls in normal housing. Gait kinematics was measured across the full range of weight bearing, and some minor alterations in gait from PWS were identified. With PWS, bone and muscle changes were generally proportional to the degree of unloading. Specifically, total body and hindlimb bone mineral density, calf muscle mass, trabecular bone volume of the distal femur, and cortical area of the femur midshaft were all linearly related to the degree of unloading. Even a load reduction to 70% of normal weight bearing was associated with significant bone deterioration and muscle atrophy. Weight bearing at 20% did not lead to better bone outcomes than HLU despite less muscle atrophy and presumably greater mechanical stimulus, requiring further investigation. These data confirm that the PWS model is highly effective in applying controllable, reduced, long-term loading that produces predictable, discrete adaptive changes in muscle and bone of the hindlimb. PMID:23165526
Compelled body weight shift approach in rehabilitation of individuals with chronic stroke.
Aruin, Alexander S; Rao, Noel; Sharma, Asha; Chaudhuri, Gouri
2012-01-01
This study was designed to evaluate the effectiveness of the compelled body weight shift (CBWS) therapy approach in the rehabilitation of individuals with chronic stroke. CBWS involves a forced shift of body weight toward a person's affected side by means of a shoe insert that establishes a lift of the nonaffected lower extremity. Eighteen individuals with chronic, unilateral stroke (mean age 57.7 ± 11.9 years, with a range of 35-75 years; mean time since stroke 6.7 ± 3.9 years, with a range of 1.1-14.1 years) who showed asymmetrical stance were randomly divided into 2 groups: the experimental group received 6 weeks of physical therapy combined with CBWS therapy, and the control group received only physical therapy. Both groups underwent a battery of identical tests (Fugl-Meyer Assessment, Berg Balance Scale, weight bearing, and gait velocity) before the start of the rehabilitation intervention, following its completion, and 3 months after the end of therapy. After the intervention, weight bearing on the affected side (measured with the Balance Master) increased in the experimental group to a larger degree compared to the control group (9.7% vs 6.4%). Similarly, gait velocity increased 10.5% in the experimental group compared to the control group. Improvements in weight bearing and gait velocity were maintained in the experimental group after the 3-month retention period. The study outcome revealed that a 6-week intervention involving CBWS therapy could result in a long-lasting improvement of the symmetry of weight bearing and velocity of gait in individuals with chronic stroke.
NASA Technical Reports Server (NTRS)
Whalley, Matthew S.
1993-01-01
A piloted simulation study was performed by the U.S. Army Aeroflighydynamics Directorate to develop insight into the maneuverability requirements for aggressive helicopter maneuvering tasks such as air-to-air combat. Both a conventional helicopter and a helicopter with auxiliary thrust were examined. The aircraft parameters of interest were the normal and longitudinal load factor envelopes. Of particular interest were the mission performance and handling qualities tradeoffs with the parameters of interest. Two air-to-air acquisition and tracking tasks and a return-to-cover task were performed to assess mission performance. Results indicate that without auxiliary thrust, the ownship normal load factor capability needs to match that of the adversary in order to provide satisfactory handling qualities. Auxiliary thrust provides significant handling qualities advantages and can be substituted to some extent for normal load factor capability. Auxiliary thrust levels as low as 0.2 thrust/weight can provide significant handling qualities advantages.
Design and test of a magnetic thrust bearing
NASA Technical Reports Server (NTRS)
Allaire, P. E.; Mikula, A.; Banerjee, B.; Lewis, D. W.; Imlach, J.
1993-01-01
A magnetic thrust bearing can be employed to take thrust loads in rotating machinery. The design and construction of a prototype magnetic thrust bearing for a high load per weight application is described. The theory for the bearing is developed. Fixtures were designed and the bearing was tested for load capacity using a universal testing machine. Various shims were employed to have known gap thicknesses. A comparison of the theory and measured results is presented.
NASA Astrophysics Data System (ADS)
Chasalevris, Athanasios; Dohnal, Fadi
2015-02-01
The idea for a journal bearing with variable geometry was formerly developed and investigated on its principles of operation giving very optimistic theoretical results for the vibration quenching of simple and more complicated rotor bearing systems during the passage through the first critical speed. The journal bearing with variable geometry is presented in this paper in its final form with the detailed design procedure. The current journal bearing was constructed in order to be applied in a simple real rotor bearing system that already exists as an experimental facility. The current paper presents details on the manufactured prototype bearing as an experimental continuation of previous works that presented the simulation of the operating principle of this journal bearing. The design parameters are discussed thoroughly under the numerical simulation for the fluid film pressure in dependency of the variable fluid film thickness during the operation conditions. The implementation of the variable geometry bearing in an experimental rotor bearing system is outlined. Various measurements highlight the efficiency of the proposed bearing element in vibration quenching during the passage through resonance. The inspiration for the current idea is based on the fact that the alteration of the fluid film characteristics of stiffness and damping during the passage through resonance results in vibration quenching. This alteration of the bearing characteristics is achieved by the introduction of an additional fluid film thickness using the passive displacement of the lower half-bearing part. • The contribution of the current journal bearing in vibration quenching. • Experimental evidence for the VGJB contribution.
Lansdaal, Joris Radboud; Mouton, Tanguy; Wascher, Daniel Charles; Demey, Guillaume; Lustig, Sebastien; Neyret, Philippe; Servien, Elvire
2017-12-01
The need for a period of non-weight bearing after medial opening wedge high tibial osteotomy remains controversial. It is hypothesized that immediate weight bearing after medial opening wedge high tibial osteotomy would have no difference in functional scores at one year compared to delayed weight bearing. Fifty patients, median age 54 years (range 40-65), with medial compartment osteoarthritis, underwent a medial opening wedge high tibial osteotomy utilizing a locking plate without bone grafting. Patients were randomized into an Immediate or a Delayed (2 months) weight bearing group. All patients were assessed at one-year follow-up and the two groups compared. The primary outcome measure was the IKS score. Secondary outcome measures included the IKDC score, the VAS pain score and rate of complications. The functional scores significantly improved in both groups. The IKS score increased from 142 ± 31 to 171 ± 26 in the Immediate group (p < 0.001) and from 148 ± 22 to 178 ± 23 in the Delayed group (p < 0.001). The IKDC score increased from 49 ± 17 pre-operatively to 68 ± 14 one-year post-operatively in the Immediate group (p < 0.0001) and from 44 ± 16 to 69 ± 19 in the Delayed group (p < 0.001). The average VAS for pain 2 months after surgery was 3 ± 3 in the Immediate group and 3 ± 2 in the Delayed (n.s.). There was no significant difference between the two groups in any of the outcome measures. The mean mechanical femorotibial angle changed from 6° of varus (0°-15° of varus, SD = 3°) to 4° of valgus (5°-11° of valgus, SD = 3°) in the Immediate group and from 5° of varus (0°-10° of varus, SD = 3°) to 3° of valgus (2° of varus to 8° of valgus, SD = 3°) in the Delayed group. No difference was seen between groups, and no loss of correction was observed in any patient. Two cases of non-union occurred, one in each group. One infection and one deep vein thrombosis occurred in the Immediate group. Immediate weight bearing after medial opening wedge high tibial osteotomy had no effect on functional scores at 1 year follow-up and did not significantly increase the complication rate. Immediate weight bearing after medial opening wedge high tibial osteotomy appears to be safe and can allow some patients a quicker return to activities of daily living and a decreased convalescence period. II.
NASA Technical Reports Server (NTRS)
Flowers, George T.
1996-01-01
This report presents a synopsis of the research work. Specific accomplishments are itemized below: (1) Experimental facilities have been developed. This includes a magnetic bearing test rig and an auxiliary bearing test rig. In addition, components have been designed, constructed, and tested for use with a rotordynamics test rig located at NASA Lewis Research Center. (2) A study of the rotordynamics of an auxiliary bearing supported T-501 engine model was performed. (3) An experimental/simulation study of auxiliary bearing rotordynamics has been performed. (4) A rotordynamical model for a magnetic bearing supported rotor system, including auxiliary bearing effects has been developed and simulation studies performed.(5) A finite element model for a foil bearing has been developed and studies of a rotor supported by foil bearings have been performed. (6) Two students affiliated with this project have graduated with M.S. degrees.
NASA Astrophysics Data System (ADS)
Tamez-Peña, José G.; Barbu-McInnis, Monica; Totterman, Saara
2006-03-01
Abnormal MR findings including cartilage defects, cartilage denuded areas, osteophytes, and bone marrow edema (BME) are used in staging and evaluating the degree of osteoarthritis (OA) in the knee. The locations of the abnormal findings have been correlated to the degree of pain and stiffness of the joint in the same location. The definition of the anatomic region in MR images is not always an objective task, due to the lack of clear anatomical features. This uncertainty causes variance in the location of the abnormality between readers and time points. Therefore, it is important to have a reproducible system to define the anatomic regions. This works present a computerized approach to define the different anatomic knee regions. The approach is based on an algorithm that uses unique features of the femur and its spatial relation in the extended knee. The femur features are found from three dimensional segmentation maps of the knee. From the segmentation maps, the algorithm automatically divides the femur cartilage into five anatomic regions: trochlea, medial weight bearing area, lateral weight bearing area, posterior medial femoral condyle, and posterior lateral femoral condyle. Furthermore, the algorithm automatically labels the medial and lateral tibia cartilage. The unsupervised definition of the knee regions allows a reproducible way to evaluate regional OA changes. This works will present the application of this automated algorithm for the regional analysis of the cartilage tissue.
Task force report on the M-2 axle/bearing failure investigation.
DOT National Transportation Integrated Search
1983-01-31
This investigation of the tubular-axle/roller-bearing failures experienced with M-2 multiple-unit cars of New York's Metropolitan Transportation Authority was aimed at establishing failure mechanisms, assessing the effectiveness of interim and long-t...
Analytical Fuselage and Wing Weight Estimation of Transport Aircraft
NASA Technical Reports Server (NTRS)
Chambers, Mark C.; Ardema, Mark D.; Patron, Anthony P.; Hahn, Andrew S.; Miura, Hirokazu; Moore, Mark D.
1996-01-01
A method of estimating the load-bearing fuselage weight and wing weight of transport aircraft based on fundamental structural principles has been developed. This method of weight estimation represents a compromise between the rapid assessment of component weight using empirical methods based on actual weights of existing aircraft, and detailed, but time-consuming, analysis using the finite element method. The method was applied to eight existing subsonic transports for validation and correlation. Integration of the resulting computer program, PDCYL, has been made into the weights-calculating module of the AirCraft SYNThesis (ACSYNT) computer program. ACSYNT has traditionally used only empirical weight estimation methods; PDCYL adds to ACSYNT a rapid, accurate means of assessing the fuselage and wing weights of unconventional aircraft. PDCYL also allows flexibility in the choice of structural concept, as well as a direct means of determining the impact of advanced materials on structural weight. Using statistical analysis techniques, relations between the load-bearing fuselage and wing weights calculated by PDCYL and corresponding actual weights were determined.
Willey, J S; Kwok, A T; Moore, J E; Payne, V; Lindburg, C A; Balk, S A; Olson, J; Black, P J; Walb, M C; Yammani, R R; Munley, M T
2016-10-01
There is little known about the effect of both reduced weight bearing and exposure to radiation during spaceflight on the mechanically-sensitive cartilage lining the knee joint. In this study, we characterized cartilage damage in rat knees after periods of reduced weight bearing with/without exposure to solar-flare-relevant radiation, then cartilage recovery after return to weight bearing. Male Sprague Dawley rats (n = 120) were either hindlimb unloaded (HLU) via tail suspension or remained weight bearing in cages (GROUND). On day 5, half of the HLU and GROUND rats were 1 Gy total-body X-ray irradiated during HLU, and half were sham irradiated (SHAM), yielding 4 groups: GROUND-SHAM; GROUND-IR; HLU-SHAM; and HLU-IR. Hindlimbs were collected from half of each group of rats on day 13. The remaining rats were then removed from HLU or remained weight bearing, and hindlimbs from these rats were collected on day 62. On day 13, glycosaminoglycan (GAG) content in cartilage lining the tibial plateau and femoral condyles of HLU rats was lower than that of the GROUND animals. Likewise, on day 13, immunoreactivity of the collagen type II-degrading matrix metalloproteinase-13 (MMP-13) and of a resultant metalloproteinase-generated neoepitope VDIPEN was increased in all groups versus GROUND-SHAM. Clustering of chondrocytes indicating cartilage damage was present in all HLU and IR groups versus GROUND-SHAM on day 13. On day 62, after 49 days of reloading, the loss of GAG content was attenuated in the HLU-SHAM and HLU-IR groups, and the increased VDIPEN staining in all treatment groups was attenuated. However, the increased chondrocyte clustering remained in all treatment groups on day 62. MMP-13 activity also remained elevated in the GROUND-IR and HLU-IR groups. Increased T2 relaxation times, measured on day 62 using 7T MRI, were greater in GROUND-IR and HLU-IR knees, indicating persistent cartilage damage in the irradiated groups. Both HLU and total-body irradiation resulted in acute degenerative and pre-arthritic changes in the knee articular cartilage of rats. A return to normal weight bearing resulted in some recovery from cartilage degradation. However, radiation delivered as both a single challenge and when combined with HLU resulted in chronic cartilage damage. These findings suggest that radiation exposure during spaceflight leads to and/or impairs recovery of cartilage upon return to reloading, generating long-term joint problems for astronauts.
NASA Technical Reports Server (NTRS)
Groom, N. J.; Woolley, C. T.; Joshi, S. M.
1981-01-01
A linear analysis and the results of a nonlinear simulation of a magnetic bearing suspension system which uses permanent magnet flux biasing are presented. The magnetic bearing suspension is part of a 4068 N-m-s (3000 lb-ft-sec) laboratory model annular momentum control device (AMCD). The simulation includes rigid body rim dynamics, linear and nonlinear axial actuators, linear radial actuators, axial and radial rim warp, and power supply and power driver current limits.
A new controller for battery-powered electric vehicles
NASA Technical Reports Server (NTRS)
Belsterling, C. A.; Stone, J.
1980-01-01
This paper describes the development, under a NASA/DOE contract, of a new concept for efficient and reliable control of battery-powered vehicles. It avoids the detrimental effects of pulsed-power controllers like the SCR 'chopper' by using rotating machines to meter continuous currents to the traction motor. The concept is validated in a proof-of-principle demonstration system and a complete vehicle is simulated on an analog computer. Test results show exceptional promise for a full-scale system. Optimum control strategies to minimize controller weight are developed by means of the simulated vehicle. The design for an Engineering Model is then prepared in the form of a practical, compact two-bearing package with forced air cooling. Predicted performance is outstanding, with controller efficiency of over 90% at high speed.
NASA Technical Reports Server (NTRS)
Lawen, James, Jr.; Flowers, George T.
1992-01-01
This study examines the response of a flexible rotor supported by load sharing between linear bearings and an auxiliary clearance bearing. The objective of the work is to develop a better understanding of the dynamical behavior of a magnetic bearing supported rotor system interacting with auxiliary bearings during a critical operating condition. Of particular interest is the effect of coupling between the bearing/housing and shaft vibration on the rotordynamical responses. A simulation model is developed and a number of studies are performed for various parametric configurations. An experimental investigation is also conducted to compare and verify the rotordynamic behavior predicted by the simulation studies. A strategy for reducing synchronous shaft vibration through appropriate design of coupled shaft/bearing/housing vibration modes is identified. The results are presented and discussed.
Choi, Ho-Suk; Shin, Won-Seob; Bang, Dae-Hyouk; Choi, Sung-Jin
2017-03-01
The aims of this work were to determine whether game-based constraint-induced movement therapy (CIMT) is effective at improving balance ability in patients with stroke, and to provide clinical knowledge of game-based training that allows application of CIMT to the lower extremities. Thirty-six patients with chronic stroke were randomly assigned to game-based CIMT (n = 12), general game-based training (n = 12), and conventional (n = 12) groups. All interventions were conducted 3 times a week for 4 weeks. The static balance control and weight-bearing symmetry were assessed, and the Functional Reach Test (FRT), modified Functional Reach Test (mFRT), and Timed Up and Go (TUG) test were performed to evaluate balance ability. All 3 groups showed significant improvement in anterior-posterior axis (AP-axis) distance, sway area, weight-bearing symmetry, FRT, mFRT, and TUG test after the intervention (P < 0.05). Post hoc analysis revealed significant differences in AP-axis, and sway area, weight-bearing symmetry of the game-based CIMT group compared with the other group (P < 0.05). Although the general game-based training and the game-based CIMT both improved on static and dynamic balance ability, game-based CIMT had a larger effect on static balance control, weight-bearing symmetry, and side-to-side weight shift.
Leung, K-S.; Li, Y-H.; Liu, Y.; Wang, H.; Tam, K-F.; Chow, D.H.K.; Wan, Y.; Ling, S.; Dai, Z.; Qin, L.; Cheung, W-H.
2015-01-01
Objectives: To investigate deterioration of musculoskeletal system due to prolonged disuse and the potential of daily short-duration weight-bearing as countermeasures. Methods: Twenty-four adult male Sprague-Dawley rats were divided into Control Group (CG, no intervention), Tail-suspension Group (TG, tail-suspension without treatment), and Weight-Bearing Group (WBG, tail-suspension with 20 min/day, 5 days/week body weight loading). After four weeks of treatment, femur and tibia, soleus and extensor digitorum longus were evaluated for bone and muscle quality respectively. Tensile properties of bone-tendon insertion (BTI) were evaluated using patella-patellar tendon complex. Results: Disuse induced deterioration on bone, muscle, and BTI after four weeks. Compared with CG, TG and WBG showed significant decrease in bone mineral density (BMD) of trabecular bone in distal femur (4.3-15.2%), muscle mass (31.3-52.3%), muscle cross-sectional area (29.1-35%), and failure strength of BTI (23.9-29.4%). Tensile test showed that the failure mode was avulsion of bone at the BTI. No significant difference was detected between TG and WBG for all assessments on bone, muscle, and BTI. Conclusions: Disuse caused deterioration of bone, muscle, and BTI while daily short-duration of weight-bearing did not prevent this deterioration. Mechanical stimulation with higher intensity and longer duration may be necessary to prevent musculoskeletal deterioration resulted from prolonged disuse. PMID:26032214
Impaired control of weight bearing ankle inversion in subjects with chronic ankle instability.
Terrier, R; Rose-Dulcina, K; Toschi, B; Forestier, N
2014-04-01
Previous studies have proposed that evertor muscle weakness represents an important factor affecting chronic ankle instability. For research purposes, ankle evertor strength is assessed by means of isokinetic evaluations. However, this methodology is constraining for daily clinical use. The present study proposes to assess ankle evertor muscle weakness using a new procedure, one that is easily accessible for rehabilitation specialists. To do so, we compared weight bearing ankle inversion control between patients suffering from chronic ankle instability and healthy subjects. 12 healthy subjects and 11 patients suffering from chronic ankle instability conducted repetitions of one leg weight bearing ankle inversion on a specific ankle destabilization device equipped with a gyroscope. Ankle inversion control was performed by means of an eccentric recruitment of evertor muscles. Instructions were to perform, as slow as possible, the ankle inversion while resisting against full body weight applied on the tested ankle. Data clearly showed higher angular inversion velocity peaks in patients suffering from chronic ankle instability. This illustrates an impaired control of weight bearing ankle inversion and, by extension, an eccentric weakness of evertor muscles. The present study supports the hypothesis of a link between the decrease of ankle joint stability and evertor muscle weakness. Moreover, it appears that the new parameter is of use in a clinical setting. Copyright © 2014 Elsevier Ltd. All rights reserved.
The effect of limb amputation on standing weight distribution in the remaining three limbs in dogs.
Cole, Grayson Lee; Millis, Darryl
2017-01-16
Despite the fact that limb amputation is a commonly performed procedure in veterinary medicine, quantitative data regarding outcomes are lacking. The intention of this study was to evaluate the effect of limb amputation on weight distribution to the remaining three limbs at a stance in dogs. Ten dogs with a prior forelimb amputation and ten dogs with a prior hindlimb amputation; all of which had no history of orthopaedic or neural disease in the remaining three limbs were included in the study. Standing weight bearing was evaluated with a commercial stance analyzer in all dogs. Five valid trials were obtained and a mean percentage of weight bearing was calculated for each remaining limb. The dogs with a previous forelimb amputation, and also those with a previous hindlimb amputation, had the largest mean increase in weight bearing in the contralateral forelimb. In conclusion, proactive monitoring of orthopaedic disease in the contralateral forelimb may be advisable in dogs with a previous limb amputation. In addition, when determining candidacy for a limb amputation, disease of the contralateral forelimb should be thoroughly evaluated.
Thewlis, Dominic; Fraysse, Francois; Callary, Stuart A; Verghese, Viju Daniel; Jones, Claire F; Findlay, David M; Atkins, Gerald J; Rickman, Mark; Solomon, Lucian B
2017-07-01
Tibial plateau fractures are complex and the current evidence for postoperative rehabilitation is weak, especially related to the recommended postoperative weight bearing. The primary aim of this study was to investigate if loading in the first 12 weeks of recovery is associated with patient reported outcome measures at 26 and 52 weeks postoperative. We hypothesized that there would be no association between loading and patient reported outcome measures. Seventeen patients, with a minimum of 52-week follow-up following fragment-specific open reduction and internal fixation for tibial plateau fracture, were selected for this retrospective analysis. Postoperatively, patients were advised to load their limb to a maximum of 20kg during the first 6 weeks. Loading data were collected during walking using force platforms. A ratio of limb loading (affected to unaffected) was calculated at 2, 6 and 12 weeks postoperative. Knee Injury and Osteoarthritis Scores were collected at 6, 12, 26 and 52 weeks postoperative. The association between loading ratios and patient reported outcomes were investigated. Compliance with weight bearing recommendations and changes in the patient reported outcome measures are described. Fracture reduction and migration were assessed on plain radiographs. No fractures demonstrated any measurable postoperative migration at 52 weeks. Significant improvements were seen in all patient reported outcome measures over the first 52 weeks, despite poor adherence to postoperative weight bearing restrictions. There were no associations between weight bearing ratio and patient reported outcomes at 52 weeks postoperative. Significant associations were identified between the loading ratio at 2 weeks and knee-related quality of life at six months (R 2 =0.392), and between the loading ratio at 6 weeks combined with injury severity and knee-related quality of life at 26 weeks (R 2 =0.441). In summary, weight bearing as tolerated does not negatively affect the results of tibial plateau fracture and may therefore be safe for postoperative management. These findings should be taken in context of the sample size, which was not sufficient for sub-group analysis to investigate the role of impaction grafting. Copyright © 2017 Elsevier Ltd. All rights reserved.
An initial test of a normative Figure Of Merit for the quality of overall task performance
NASA Technical Reports Server (NTRS)
Lemay, Moira; Comstock, J. R., Jr.
1990-01-01
An overall indicator, or Figure Of Merit (FOM), of the quality of crew/vehicle system performance is needed to establish the effect of workload on efficiency and to identify overload conditions. A normative FOM is proposed in which performance is measured on a representative task and a normative data base obtained. FOMs for subsequent executions of the task are then reported in terms of weighted deviations from average task performance. Performance of discrete tasks is measured primarily in terms of subtask time and errors. Discrete task performance is then combined with a measure of continuous vehicle control. In order to test the normative FOM procedure, the technique was applied to an existing set of data from a simulated landing task in which standard communications with ATC was compared with a data link communications system. The results indicated that while mean task performance was not affected, task variability, as measured by the FOM, was significantly higher when data link communications were used. In order to establish the sensitivity of the normative FOM method, further testing of the measure is recommended.
Role of Glucocorticoids in the Response to Unloading of Muscle Protein and Amino Acid Metabolism
NASA Technical Reports Server (NTRS)
Tischler, M. E.; Jaspers, S. R.
1985-01-01
Intact control (weight bearing) and suspended rats gained weight at a similar rate during a 6 day period. Adrenaectomized (adx) weight bearing rats gained less weight during this period while adrenalectomized suspended rats showed no significant weight gain. Cortisol treatment of both of these groups of animals caused a loss of body weight. Results from these studies show several important findings: (1) Metabolic changes in the extensor digitorum longus muscle of suspended rats are due primarily to increased circulating gluccorticoids; (2) Metabolic changes in the soleus due to higher steroid levels are probably potentiated by greater numbers of receptors; and (3) Not all metabolic responses in the unloaded soleus muscle are due to direct action of elevated glucocorticoids or increased sensitivity to these hormones.
FEASIBILITY STUDY OF AIR BEARING ROCKET SLED SLIPPERS
a simple self-acting type of bearing can support a typical monorail rocket sled, without contact between the slipper and the rail, at speeds between...slipper bearing is capable of preventing slipper-rail contact over the entire speed range of typical monorail and dual rail sleds. However, the weight and
Parameter Design and Optimal Control of an Open Core Flywheel Energy Storage System
NASA Technical Reports Server (NTRS)
Pang, D.; Anand, D. K.; Kirk, J. A.
1996-01-01
In low earth orbit (LEO) satellite applications spacecraft power is provided by photovoltaic cells and batteries. To overcome battery shortcomings the University of Maryland, working in cooperation with NASA/GSFC and NASA/LeRC, has developed a magnetically suspended flywheel for energy storage applications. The system is referred to as an Open Core Composite Flywheel (OCCF) energy storage system. Successful application of flywheel energy storage requires integration of several technologies, viz. bearings, rotor design, motor/generator, power conditioning, and system control. In this paper we present a parameter design method which has been developed for analyzing the linear SISO model of the magnetic bearing controller for the OCCF. The objective of this continued research is to principally analyze the magnetic bearing system for nonlinear effects in order to increase the region of stability, as determined by high speed and large air gap control. This is achieved by four tasks: (1) physical modeling, design, prototyping, and testing of an improved magnetically suspended flywheel energy storage system, (2) identification of problems that limit performance and their corresponding solutions, (3) development of a design methodology for magnetic bearings, and (4) design of an optimal controller for future high speed applications. Both nonlinear SISO and MIMO models of the magnetic system were built to study limit cycle oscillations and power amplifier saturation phenomenon observed in experiments. The nonlinear models include the inductance of EM coils, the power amplifier saturation, and the physical limitation of the flywheel movement as discussed earlier. The control program EASY5 is used to study the nonlinear SISO and MIMO models. Our results have shown that the characteristics and frequency responses of the magnetic bearing system obtained from modeling are comparable to those obtained experimentally. Although magnetic saturation is shown in the bearings, there are good correlations between the theoretical model and experimental data. Both simulation and experiment confirm large variations of the magnetic bearing characteristics due to air gap growth. Therefore, the gap growth effect should be considered in the magnetic bearing system design. Additionally, the magnetic bearing control system will be compared to other design methods using not only parameter design but H-infinity optimal control and mu synthesis.
Understanding Skill in EVA Mass Handling. Volume 2; Empirical Investigation
NASA Technical Reports Server (NTRS)
Riccio, Gary; McDonald, Vernon; Peters, Brian; Layne, Charles; Bloomberg, Jacob
1997-01-01
In this report we describe the details of our empirical protocol effort investigating skill in extravehicular mass handling using NASA's principal mass handling simulator, the precision air bearing floor. Contents of this report include a description of the necessary modifications to the mass handling simulator; choice of task, and the description of an operationally relevant protocol. Our independent variables are presented in the context of the specific operational issues they were designed to simulate. The explanation of our dependent variables focuses on the specific data processing procedures used to transform data from common laboratory instruments into measures that are relevant to a special class of nested control systems (discussed in Volume 1): manual interactions between an individual and the substantial environment. The data reduction is explained in the context of the theoretical foundation described in Volume 1. Finally as a preface to the presentation of the empirical data in Volume 3 of this report series, a set of detailed hypotheses is presented.
Development of VR simulator for nurse training
NASA Astrophysics Data System (ADS)
Nakagawa, Y.; Tsetserukou, D.; Terashima, K.
2014-02-01
Our research focuses on the development of the VR simulator NurseSim to train nurse and hospital aides how to carry unconscious or injured person. The motivation behind this project is the fact that nurses consider patient lifting, transfer, and turning as most physically demanding. The user experiences the 3D environment in which they hold the subject. The task is to maintain such posture so that to prevent further injuries of the patient and distribute the weight of the patient over both hands evenly. Nurses are taught to mitigate and manage fatigue while at work.
Astronaut Jones donning EMU during space walk simulations for STS-59
1993-08-16
Astronaut Thomas D. Jones, mission specialist, dons a space suit prior to participating in contingency space walk simulations at the JSC Weightless Environment Training Facility (WETF). Jones is assisted by Frank Hernandez (left) and suit technician Charles Hudson of Hamilton Standard. Jones suit is weighted to that he can achieve a neutrally buoyant state once under water. Extravehicular tasks are not planned for the STS-59 mission, but a number of chores are rehearsed in case of failure of remote systems to perform those jobs.
NASA Technical Reports Server (NTRS)
Mcdonald, Gary H.
1987-01-01
The MSFC bearing seal material tester (BSMT) can be used to evaluate the SSME high pressure oxygen turbopump (HPOTP) bearing performance. The four HPOTP bearings have both an imposed radial and axial load. These radial and axial loads are caused by the HPOTP's shaft, main impeller, preburner impeller, turbine and by the LOX coolant flow through the bearings, respectively. These loads coupled with bearing geometry and operating speed can define bearing contact angle, contact Hertz stress, and heat generation rates. The BSMT has the capability of operating at HPOTP shaft speeds, provide proper coolant flowrates but can only apply an axial load. Due to the inability to operate the bearings in the BSMT with an applied radial load, it is important to develop an equivalency between the applied axial loads and the actual HPOTP loadings. A shaft-bearing-thermal computer code (SHABERTH/SINDA) is used to simulate the BSMT bearing-shaft geometry and thermal-fluid operating conditions.
Kinematic cues in perceptual weight judgement and their origins in box lifting
Hamilton, A.; Joyce, D. W.; Flanagan, R.; Frith, C. D.; Wolpert, D. M.
2009-01-01
When accepting a parcel from another person, we are able to use information about that person’s movement to estimate in advance the weight of the parcel, that is, to judge its weight from observed action. Perceptual weight judgment provides a powerful method to study our interpretation of other people’s actions, but it is not known what sources of information are used in judging weight. We have manipulated full form videos to obtain precise control of the perceived kinematics of a box lifting action, and use this technique to explore the kinematic cues that affect weight judgment. We find that observers rely most on the duration of the lifting movement to judge weight, and make less use of the durations of the grasp phase, when the box is first gripped, or the place phase, when the box is put down. These findings can be compared to the kinematics of natural box lifting behaviour, where we find that the duration of the grasp component is the best predictor of true box weight. The lack of accord between the optimal cues predicted by the natural behaviour and the cues actually used in the perceptual task has implications for our understanding of action observation in terms of a motor simulation. The differences between perceptual and motor behaviour are evidence against a strong version of the motor simulation hypothesis. PMID:16311765
Dumas, Jerald E.; Prieto, Edna M.; Zienkiewicz, Katarzyna J.; Guda, Teja; Wenke, Joseph C.; Bible, Jesse; Holt, Ginger E.
2014-01-01
There is a compelling clinical need for bone grafts with initial bone-like mechanical properties that actively remodel for repair of weight-bearing bone defects, such as fractures of the tibial plateau and vertebrae. However, there is a paucity of studies investigating remodeling of weight-bearing bone grafts in preclinical models, and consequently there is limited understanding of the mechanisms by which these grafts remodel in vivo. In this study, we investigated the effects of the rates of new bone formation, matrix resorption, and polymer degradation on healing of settable weight-bearing polyurethane/allograft composites in a rabbit femoral condyle defect model. The grafts induced progressive healing in vivo, as evidenced by an increase in new bone formation, as well as a decrease in residual allograft and polymer from 6 to 12 weeks. However, the mismatch between the rates of autocatalytic polymer degradation and zero-order (independent of time) new bone formation resulted in incomplete healing in the interior of the composite. Augmentation of the grafts with recombinant human bone morphogenetic protein-2 not only increased the rate of new bone formation, but also altered the degradation mechanism of the polymer to approximate a zero-order process. The consequent matching of the rates of new bone formation and polymer degradation resulted in more extensive healing at later time points in all regions of the graft. These observations underscore the importance of balancing the rates of new bone formation and degradation to promote healing of settable weight-bearing bone grafts that maintain bone-like strength, while actively remodeling. PMID:23941405
A new distraction arthroplasty device using magnetic force; a cadaveric study.
Kamei, Goki; Ochi, Mitsuo; Okuhara, Atsushi; Fujimiya, Mineko; Deie, Masataka; Adachi, Nobuo; Nakamae, Atsuo; Nakasa, Tomoyuki; Ohkawa, Shingo; Takazawa, Kobun; Eguchi, Akio; Katou, Tomohiro; Takada, Tsuyoshi; Usman, Muhammad Andry
2013-04-01
It is difficult for an articular cartilage injury to repair spontaneously. There are many procedures for treating cartilage injury, however there is no standard procedure for middle-aged patients who have diffuse knee osteoarthritis, especially of the lateral compartment. Therefore, Ochi developed a new distraction device that uses magnetic power to enlarge a joint space and promote cartilage regeneration with microfracture. The purpose of this study is to evaluate this new distraction arthroplasty system by using the cadaveric knee. This study used ten knees from six cadavers that were embalmed by Thiel's methods. The medial and lateral joint space was measured by AP radiographic view before and after distraction, and after weight-bearing to evaluate the joint distraction. The contact pressure of the medial and lateral compartments at the knee extension position by using a prescale film system was measured before and after weight-bearing with a 15 or 30-kg weight-bearing load to evaluate the effectiveness of this device. The lateral joint space significantly increased from the pre-distraction to the post-distraction; however, it did not change significantly between post-distraction and post-weight-bearing. With a 15 or 30-kg weight-bearing load, the contact pressure of the lateral compartment significantly decreased from the pre-distraction to the post-distraction. The most important advantage of this device is that it maintains a continuous distraction tension and enables almost the full range of motion of the knee. We believe that joint distraction by using magnetic force can be a promising option for cartilage injury in middle-aged patients. Copyright © 2013 Elsevier Ltd. All rights reserved.
2013-01-01
Background The validity of studies describing clinicians’ judgements based on their responses to paper cases is questionable, because - commonly used - paper case simulations only partly reflect real clinical environments. In this study we test whether paper case simulations evoke similar risk assessment judgements to the more realistic simulated patients used in high fidelity physical simulations. Methods 97 nurses (34 experienced nurses and 63 student nurses) made dichotomous assessments of risk of acute deterioration on the same 25 simulated scenarios in both paper case and physical simulation settings. Scenarios were generated from real patient cases. Measures of judgement ‘ecology’ were derived from the same case records. The relationship between nurses’ judgements, actual patient outcomes (i.e. ecological criteria), and patient characteristics were described using the methodology of judgement analysis. Logistic regression models were constructed to calculate Lens Model Equation parameters. Parameters were then compared between the modeled paper-case and physical-simulation judgements. Results Participants had significantly less achievement (ra) judging physical simulations than when judging paper cases. They used less modelable knowledge (G) with physical simulations than with paper cases, while retaining similar cognitive control and consistency on repeated patients. Respiration rate, the most important cue for predicting patient risk in the ecological model, was weighted most heavily by participants. Conclusions To the extent that accuracy in judgement analysis studies is a function of task representativeness, improving task representativeness via high fidelity physical simulations resulted in lower judgement performance in risk assessments amongst nurses when compared to paper case simulations. Lens Model statistics could prove useful when comparing different options for the design of simulations used in clinical judgement analysis. The approach outlined may be of value to those designing and evaluating clinical simulations as part of education and training strategies aimed at improving clinical judgement and reasoning. PMID:23718556
An experimental study of human pilot's scanning behavior
NASA Technical Reports Server (NTRS)
Washizu, K.; Tanaka, K.; Osawa, T.
1982-01-01
The scanning behavior and the control behavior of the pilot who manually controls the two-variable system, which is the most basic one of multi-variable systems are investigated. Two control tasks which simulate the actual airplane attitude and airspeed control were set up. In order to simulate the change of the situation where the pilot is placed, such as changes of flight phase, mission and others, the subject was requested to vary the weightings, as his control strategy, upon each task. Changes of human control dynamics and his canning properties caused by the modification of the situation were investigated. By making use of the experimental results, the optimal model of the control behavior and the scanning behavior of the pilot in the two-variable system is proposed from the standpoint of making the performance index minimal.
Compelled Body-Weight Shift Approach in Rehabilitation of Individuals with Chronic Stroke
Aruin, Alexander S.; Rao, Noel; Sharma, Asha; Chaudhuri, Gouri
2013-01-01
Purpose To evaluate the effectiveness of the Compelled Body Weight Shift (CBWS) therapy approach in the rehabilitation of individuals with chronic stroke. CBWS involves a forced shift of body weight towards a person’s affected side by means of a shoe insert that establishes a lift of the non-affected lower extremity. Method Eighteen individuals with chronic, unilateral stroke (mean age 57.7 ± 11.9 years, with a range of 35–75 years, mean time since stroke 6.7±3.9 years with a range of 1.1–14.1 years) who showed asymmetrical stance were randomly divided into two groups: the experimental group received a six-week physical therapy combined with CBWS therapy and the control group received only physical therapy. Both groups underwent a battery of identical tests (Fugl-Meyer assessment, Berg Balance Scale, weight bearing, and gait velocity) before the start of the rehabilitation intervention, following its completion, and three months after the end of therapy. Results After the intervention, weight bearing on the affected side (measured with the Balance Master®) increased in the experimental group to a larger degree compared to the control group (9.7% vs. 6.4%). Similarly, gait velocity increased 10.5% in the experimental group compared to the control group. Improvements in weight bearing and gait velocity were maintained in the experimental group after the three month retention period. Conclusion The study outcome revealed that a six-week intervention involving CBWS therapy could result in a long-lasting improvement of the symmetry of weight bearing and velocity of gait in individuals with chronic stroke. PMID:23192720
Analytical Fuselage and Wing Weight Estimation of Transport Aircraft
DOT National Transportation Integrated Search
1996-05-01
A method of estimating the load-bearing fuselage weight and wing weight of transport aircraft based on fundamental structural principles has been developed. This method of weight estimation represents a compromise between the rapid assessment of comp...
NASA Technical Reports Server (NTRS)
Schultheis, L.; Ruff, C. B.; Rastogi, S.; Bloomfield, S.; Hogan, H. A.; Fedarko, N.; Thierry-Palmer, M.; Ruiz, J.; Bauss, F.; Shapiro, J. R.
2000-01-01
The purpose of this study was to evaluate potential countermeasures for bone loss during long-term space missions in the hindquarter suspended rat, including partial weight bearing (surrogate for artificial gravity) episodic full weight bearing (2 hour/day full weight bearing) and treatment with the third generation bisphosphonate ibandronate (Roche). Graded mechanical loading was studied by housing the animals on a novel servo controlled force plate system which permitted the titration of mechanical force at varying frequency and amplitude and different levels of weight bearing. The force plate, which forms the cage floor, is a glass platform supported by an 18" diameter speaker cone filled with expanding polyurethane foam. An infrared optical sensor attached to the speaker cone yields a voltage linearly related to vertical displacement of the glass platform. The dynamic force on the paw was computed as a product of the apparent mass of the animal on the platform at rest and the acceleration of the platform determined from the second derivative of the optical sensor output. The mass of the animal on the platform was varied by adjusting tension on the tether suspending the animal. Mechanical impact loading was titrated with the force plate resonating at different frequencies, including 3 Hz and 16 Hz.
Takacs, Judit; Leiter, Jeff R S; Peeler, Jason D
2011-06-01
Lower extremity fractures, if not treated appropriately, can increase the risk of morbidity. Partial weight-bearing after surgical repair is recommended; however, current methods of partial weight-bearing may cause excessive loads through the lower extremity. A new rehabilitation tool that uses lower body positive-pressure is described, that may allow partial weight-bearing while preventing excessive loads, thereby improving functional outcomes. A patient with multiple lower extremity fractures underwent a 6-month rehabilitation programme using bodyweight support technology 3 times per week, post-surgery. The patient experienced a reduction in pain and an improvement in ankle range of motion (p=0.002), walking speed (p>0.05) and physical function (p=0.004), as assessed by the Foot and Ankle Module of the American Academy of Orthopaedic Surgeons Lower Limb Outcomes Assessment Instrument. Training did not appear to affect fracture healing, as was evident on radiograph. The effect of lower body positive-pressure on effusion, which has not previously been reported in the literature, was also investigated. No significant difference in effusion of the foot and ankle when using lower body positive-pressure was found. Initial results suggest that this new technology may be a useful rehabilitation tool that allows partial weight-bearing during the treatment of lower extremity injuries.
Zhou, Shenghan; Qian, Silin; Chang, Wenbing; Xiao, Yiyong; Cheng, Yang
2018-06-14
Timely and accurate state detection and fault diagnosis of rolling element bearings are very critical to ensuring the reliability of rotating machinery. This paper proposes a novel method of rolling bearing fault diagnosis based on a combination of ensemble empirical mode decomposition (EEMD), weighted permutation entropy (WPE) and an improved support vector machine (SVM) ensemble classifier. A hybrid voting (HV) strategy that combines SVM-based classifiers and cloud similarity measurement (CSM) was employed to improve the classification accuracy. First, the WPE value of the bearing vibration signal was calculated to detect the fault. Secondly, if a bearing fault occurred, the vibration signal was decomposed into a set of intrinsic mode functions (IMFs) by EEMD. The WPE values of the first several IMFs were calculated to form the fault feature vectors. Then, the SVM ensemble classifier was composed of binary SVM and the HV strategy to identify the bearing multi-fault types. Finally, the proposed model was fully evaluated by experiments and comparative studies. The results demonstrate that the proposed method can effectively detect bearing faults and maintain a high accuracy rate of fault recognition when a small number of training samples are available.
Elastic properties of gas hydrate-bearing sediments
Lee, M.W.; Collett, T.S.
2001-01-01
Downhole-measured compressional- and shear-wave velocities acquired in the Mallik 2L-38 gas hydrate research well, northwestern Canada, reveal that the dominant effect of gas hydrate on the elastic properties of gas hydrate-bearing sediments is as a pore-filling constituent. As opposed to high elastic velocities predicted from a cementation theory, whereby a small amount of gas hydrate in the pore space significantly increases the elastic velocities, the velocity increase from gas hydrate saturation in the sediment pore space is small. Both the effective medium theory and a weighted equation predict a slight increase of velocities from gas hydrate concentration, similar to the field-observed velocities; however, the weighted equation more accurately describes the compressional- and shear-wave velocities of gas hydrate-bearing sediments. A decrease of Poisson's ratio with an increase in the gas hydrate concentration is similar to a decrease of Poisson's ratio with a decrease in the sediment porosity. Poisson's ratios greater than 0.33 for gas hydrate-bearing sediments imply the unconsolidated nature of gas hydrate-bearing sediments at this well site. The seismic characteristics of gas hydrate-bearing sediments at this site can be used to compare and evaluate other gas hydrate-bearing sediments in the Arctic.
Monte Carlo Simulation of Sudden Death Bearing Testing
NASA Technical Reports Server (NTRS)
Vlcek, Brian L.; Hendricks, Robert C.; Zaretsky, Erwin V.
2003-01-01
Monte Carlo simulations combined with sudden death testing were used to compare resultant bearing lives to the calculated hearing life and the cumulative test time and calendar time relative to sequential and censored sequential testing. A total of 30 960 virtual 50-mm bore deep-groove ball bearings were evaluated in 33 different sudden death test configurations comprising 36, 72, and 144 bearings each. Variations in both life and Weibull slope were a function of the number of bearings failed independent of the test method used and not the total number of bearings tested. Variation in L10 life as a function of number of bearings failed were similar to variations in lift obtained from sequentially failed real bearings and from Monte Carlo (virtual) testing of entire populations. Reductions up to 40 percent in bearing test time and calendar time can be achieved by testing to failure or the L(sub 50) life and terminating all testing when the last of the predetermined bearing failures has occurred. Sudden death testing is not a more efficient method to reduce bearing test time or calendar time when compared to censored sequential testing.
Firkins, P; Hailey, J L; Fisher, J; Lettington, A H; Butter, R
1998-10-01
The wear of ultra-high molecular weight polyethylene (UHMWPE) in artificial joints and the resulting wear debris-induced osteolysis remains a major clinical concern in the orthopaedic sector. Third-body damage of metallic femoral heads is often cited as a cause of accelerated polyethylene wear, and the use of ceramic femoral heads in the hip is gaining increasing favour. In the knee prostheses and for smaller diameter femoral heads, the application of hard surface coatings, such as diamond-like carbon, is receiving considerable attention. However, to date, there has been little or no investigation of the tribology of these coatings in simulated biological environments. In this study, diamond-like carbon (DLC) has been compared to stainless steel in its undamaged form and following simulated third-body damage. The wear of UHMWPE was found to be similar when sliding against undamaged DLC and stainless steel counterfaces. DLC was found to be much more damage resistant than DLC. Under test conditions that simulate third-body damage to the femoral head, the wear of UHMWPE was seven times lower against DLC than against stainless steel (P < 0.05). The study shows DLC has considerable potential as a femoral bearing surface in artificial joints.
A new task scheduling algorithm based on value and time for cloud platform
NASA Astrophysics Data System (ADS)
Kuang, Ling; Zhang, Lichen
2017-08-01
Tasks scheduling, a key part of increasing resource utilization and enhancing system performance, is a never outdated problem especially in cloud platforms. Based on the value density algorithm of the real-time task scheduling system and the character of the distributed system, the paper present a new task scheduling algorithm by further studying the cloud technology and the real-time system: Least Level Value Density First (LLVDF). The algorithm not only introduces some attributes of time and value for tasks, it also can describe weighting relationships between these properties mathematically. As this feature of the algorithm, it can gain some advantages to distinguish between different tasks more dynamically and more reasonably. When the scheme was used in the priority calculation of the dynamic task scheduling on cloud platform, relying on its advantage, it can schedule and distinguish tasks with large amounts and many kinds more efficiently. The paper designs some experiments, some distributed server simulation models based on M/M/C model of queuing theory and negative arrivals, to compare the algorithm against traditional algorithm to observe and show its characters and advantages.
DOT National Transportation Integrated Search
2015-05-01
The overall goal of this project is the experimental evaluation and design of unfilled and concrete-filled FRP composite piles for load-bearing in bridges. This report covers Task 7, Final Report - Thesis. : This final report covers Tasks 1, 2, 3, 5 ...
Feasibility of magnetic bearings for advanced gas turbine engines
NASA Technical Reports Server (NTRS)
Hibner, David; Rosado, Lewis
1992-01-01
The application of active magnetic bearings to advanced gas turbine engines will provide a product with major improvements compared to current oil lubricated bearing designs. A rethinking of the engine rotating and static structure design is necessary and will provide the designer with significantly more freedom to meet the demanding goals of improved performance, increased durability, higher reliability, and increased thrust to weight ratio via engine weight reduction. The product specific technology necessary for this high speed, high temperature, dynamically complex application has been defined. The resulting benefits from this approach to aircraft engine rotor support and the complementary engine changes and improvements have been assessed.
van Amstel, Sarel R
2017-07-01
Corkscrew claw (CSC) is a conformational abnormality of the digit and affecting mostly but not exclusively the claws of the back leg, first reported during the 1950s in Dutch black and white cattle. The affected claws are longer and narrower than the claw and have an inward and upward spiral rotation of the toe. Similarly, the bearing surface of the wall is displaced inward. The animal starts to bear weight on the abaxial wall surface, particularly the caudal segment, and the sole may become completely non-weight bearing. The axial wall is displaced dorsomedially and a fold develops in the wall. Copyright © 2017 Elsevier Inc. All rights reserved.
Analysis of Skeletal Muscle Metrics as Predictors of Functional Task Performance
NASA Technical Reports Server (NTRS)
Ryder, Jeffrey W.; Buxton, Roxanne E.; Redd, Elizabeth; Scott-Pandorf, Melissa; Hackney, Kyle J.; Fiedler, James; Ploutz-Snyder, Robert J.; Bloomberg, Jacob J.; Ploutz-Snyder, Lori L.
2010-01-01
PURPOSE: The ability to predict task performance using physiological performance metrics is vital to ensure that astronauts can execute their jobs safely and effectively. This investigation used a weighted suit to evaluate task performance at various ratios of strength, power, and endurance to body weight. METHODS: Twenty subjects completed muscle performance tests and functional tasks representative of those that would be required of astronauts during planetary exploration (see table for specific tests/tasks). Subjects performed functional tasks while wearing a weighted suit with additional loads ranging from 0-120% of initial body weight. Performance metrics were time to completion for all tasks except hatch opening, which consisted of total work. Task performance metrics were plotted against muscle metrics normalized to "body weight" (subject weight + external load; BW) for each trial. Fractional polynomial regression was used to model the relationship between muscle and task performance. CONCLUSION: LPMIF/BW is the best predictor of performance for predominantly lower-body tasks that are ambulatory and of short duration. LPMIF/BW is a very practical predictor of occupational task performance as it is quick and relatively safe to perform. Accordingly, bench press work best predicts hatch-opening work performance.
Accelerated weight histogram method for exploring free energy landscapes
NASA Astrophysics Data System (ADS)
Lindahl, V.; Lidmar, J.; Hess, B.
2014-07-01
Calculating free energies is an important and notoriously difficult task for molecular simulations. The rapid increase in computational power has made it possible to probe increasingly complex systems, yet extracting accurate free energies from these simulations remains a major challenge. Fully exploring the free energy landscape of, say, a biological macromolecule typically requires sampling large conformational changes and slow transitions. Often, the only feasible way to study such a system is to simulate it using an enhanced sampling method. The accelerated weight histogram (AWH) method is a new, efficient extended ensemble sampling technique which adaptively biases the simulation to promote exploration of the free energy landscape. The AWH method uses a probability weight histogram which allows for efficient free energy updates and results in an easy discretization procedure. A major advantage of the method is its general formulation, making it a powerful platform for developing further extensions and analyzing its relation to already existing methods. Here, we demonstrate its efficiency and general applicability by calculating the potential of mean force along a reaction coordinate for both a single dimension and multiple dimensions. We make use of a non-uniform, free energy dependent target distribution in reaction coordinate space so that computational efforts are not wasted on physically irrelevant regions. We present numerical results for molecular dynamics simulations of lithium acetate in solution and chignolin, a 10-residue long peptide that folds into a β-hairpin. We further present practical guidelines for setting up and running an AWH simulation.
Accelerated weight histogram method for exploring free energy landscapes.
Lindahl, V; Lidmar, J; Hess, B
2014-07-28
Calculating free energies is an important and notoriously difficult task for molecular simulations. The rapid increase in computational power has made it possible to probe increasingly complex systems, yet extracting accurate free energies from these simulations remains a major challenge. Fully exploring the free energy landscape of, say, a biological macromolecule typically requires sampling large conformational changes and slow transitions. Often, the only feasible way to study such a system is to simulate it using an enhanced sampling method. The accelerated weight histogram (AWH) method is a new, efficient extended ensemble sampling technique which adaptively biases the simulation to promote exploration of the free energy landscape. The AWH method uses a probability weight histogram which allows for efficient free energy updates and results in an easy discretization procedure. A major advantage of the method is its general formulation, making it a powerful platform for developing further extensions and analyzing its relation to already existing methods. Here, we demonstrate its efficiency and general applicability by calculating the potential of mean force along a reaction coordinate for both a single dimension and multiple dimensions. We make use of a non-uniform, free energy dependent target distribution in reaction coordinate space so that computational efforts are not wasted on physically irrelevant regions. We present numerical results for molecular dynamics simulations of lithium acetate in solution and chignolin, a 10-residue long peptide that folds into a β-hairpin. We further present practical guidelines for setting up and running an AWH simulation.
Moglia, Andrea; Morelli, Luca; Ferrari, Vincenzo; Ferrari, Mauro; Mosca, Franco; Cuschieri, Alfred
2018-03-14
There is an increasing interest for a test assessing objectively the innate aptitude for surgery as a craft specialty to complement the current selection process of surgical residents. The aim of this study was to quantify the size of individuals with high, average, and low level of innate psychomotor skills among medical students. A volunteer sample of 155 medical students, without prior experience with surgical simulator, executed five tasks at a virtual simulator for robot-assisted surgery. They had to reach proficiency twice consecutively in each before moving to the next one. A weighting based on time and number of attempts needed to reach proficiency was assigned to each task. Nine students (5.8%) out of 155 significantly outperformed all the others on median (i.q.r.) weighted time [44.7 (42.2-47.3) min vs. 98.5 (70.8-131.8) min, p < 0.001], and number of attempts to reach proficiency [14 (12-15) vs. 23 (19-32.75), p < 0.001). Seventeen students (11.0%) scored significantly much worse than the rest on median weighted time [202.2 (182.5-221.0) min vs. 84.3 (65.7-114.4) min, p < 0.001], and number of attempts [42 (40-48) vs. 22 (17.25-28), p < 0.001]. Low correlation between simulator scores and extracurricular activities, like videogames and musical instruments, was found. The test successfully identified two groups straddling the large cohort with average innate aptitude for psychomotor skills: (i) innately gifted and (ii) with scarce level. Hence, exercises on a virtual simulator are a valid test of innate manual dexterity and can be considered to complement the selection process for a surgical training program, primarily to identify individuals with low innate aptitude for surgery and advise them to consider specialization in other (non-craft) medical specialties.
Simulating polar bear energetics during a seasonal fast using a mechanistic model.
Mathewson, Paul D; Porter, Warren P
2013-01-01
In this study we tested the ability of a mechanistic model (Niche Mapper™) to accurately model adult, non-denning polar bear (Ursus maritimus) energetics while fasting during the ice-free season in the western Hudson Bay. The model uses a steady state heat balance approach, which calculates the metabolic rate that will allow an animal to maintain its core temperature in its particular microclimate conditions. Predicted weight loss for a 120 day fast typical of the 1990s was comparable to empirical studies of the population, and the model was able to reach a heat balance at the target metabolic rate for the entire fast, supporting use of the model to explore the impacts of climate change on polar bears. Niche Mapper predicted that all but the poorest condition bears would survive a 120 day fast under current climate conditions. When the fast extended to 180 days, Niche Mapper predicted mortality of up to 18% for males. Our results illustrate how environmental conditions, variation in animal properties, and thermoregulation processes may impact survival during extended fasts because polar bears were predicted to require additional energetic expenditure for thermoregulation during a 180 day fast. A uniform 3°C temperature increase reduced male mortality during a 180 day fast from 18% to 15%. Niche Mapper explicitly links an animal's energetics to environmental conditions and thus can be a valuable tool to help inform predictions of climate-related population changes. Since Niche Mapper is a generic model, it can make energetic predictions for other species threatened by climate change.
Simulating Polar Bear Energetics during a Seasonal Fast Using a Mechanistic Model
Mathewson, Paul D.; Porter, Warren P.
2013-01-01
In this study we tested the ability of a mechanistic model (Niche Mapper™) to accurately model adult, non-denning polar bear (Ursus maritimus) energetics while fasting during the ice-free season in the western Hudson Bay. The model uses a steady state heat balance approach, which calculates the metabolic rate that will allow an animal to maintain its core temperature in its particular microclimate conditions. Predicted weight loss for a 120 day fast typical of the 1990s was comparable to empirical studies of the population, and the model was able to reach a heat balance at the target metabolic rate for the entire fast, supporting use of the model to explore the impacts of climate change on polar bears. Niche Mapper predicted that all but the poorest condition bears would survive a 120 day fast under current climate conditions. When the fast extended to 180 days, Niche Mapper predicted mortality of up to 18% for males. Our results illustrate how environmental conditions, variation in animal properties, and thermoregulation processes may impact survival during extended fasts because polar bears were predicted to require additional energetic expenditure for thermoregulation during a 180 day fast. A uniform 3°C temperature increase reduced male mortality during a 180 day fast from 18% to 15%. Niche Mapper explicitly links an animal’s energetics to environmental conditions and thus can be a valuable tool to help inform predictions of climate-related population changes. Since Niche Mapper is a generic model, it can make energetic predictions for other species threatened by climate change. PMID:24019883
Telemetry experiments with a hibernating black bear
NASA Technical Reports Server (NTRS)
Craighead, J. J.; Varney, J. R.; Sumner, J. S.; Craighead, F. C., Jr.
1972-01-01
The objectives of this research were to develop and test telemetry equipment suitable for monitoring physiological parameters and activity of a hibernating bear in its den, to monitor this data and other environmental information with the Nimbus 3 IRLS data collection system, and to refine immobilizing, handling, and other techniques required in future work with wild bears under natural conditions. A temperature-telemetering transmitter was implanted in the abdominal cavity of a captive black bear and body temperature data was recorded continuously during a 3 month hibernation period. Body temperatures ranging between 37.5 and 31.8 C were observed. Body temperature and overall activity were influenced by disturbances and ambient den temperature. Nychthemeral temperature changes were not noticable. A load cell weight recording device was tested for determining weight loss during hibernation. Monitoring of data by satellite was not attempted. The implanted transmitter was removed and the bear was released with a radiolocation collar at the conclusion of the experiment.
Compelled Body Weight Shift Technique to Facilitate Rehabilitation of Individuals with Acute Stroke.
Mohapatra, Sambit; Eviota, Aileen C; Ringquist, Keir L; Muthukrishnan, Sri Ranjini; Aruin, Alexander S
2012-05-01
The study evaluates the effectiveness of Compelled Body Weight Shift (CBWS) approach in the rehabilitation of individuals with stroke. CBWS involves a forced shift of body weight towards a person's affected side by means of a shoe insert that establishes a lift of the nonaffected lower extremity. Eleven patients with acute stroke were randomly assigned to experimental and control groups. The experimental group received a two-week conventional physical therapy combined with CBWS and the control group received only a two-week conventional therapy. Weight bearing, Gait velocity, Berg's Balance, and Fugl-Meyer's Scores were recorded before and after the intervention. Weight bearing on the affected side increased in the experimental group and decreased in the control group. The increase in gait velocity with treatment was significant in both the groups ( P < 0.05). However, experimental group ( P = 0.01) demonstrated larger improvements in gait velocity compared to the control group ( P = 0.002). Berg Balance and Fugl-Meyer scores increased for both the groups. The implementation of a two-week intervention with CBWS resulted in the improvement in weight bearing and gait velocity of individuals with acute stroke. The present preliminary study suggests that CBWS technique could be implemented as an adjunct to conventional rehabilitation program for individuals with acute stroke.
Case 24: Stress Fracture of the Tibia
2008-03-01
extremity weight bearing bones. Most often this micro trauma is found in military recruits and athletes taking part in running activities. A...application of force most commonly related to running and jumping results in micro trauma to the cortical bone. The weight bearing bones of the lower...year old active duty U.S Army combat soldier deployed to Iraq. He had had progressive pain over his lower right leg that radiated to his knee joint
Multiple Tibial Insufficiency Fractures in the Same Tibia
Defoort, Saartje; Mertens, Peter
2011-01-01
Stress fractures were first described by Briethaupt in 1855. Since then, there have been many discussions in the literature concerning stress fractures, which have been described in both weight-bearing and non-weight-bearing bones. Currently, the tibia is the most frequent location, but multiple stress fractures in the same tibia are rare. This paper presents an unusual case of a 60-year-old woman with multiple tibial stress fractures of spontaneous onset. PMID:23569673
Recovery of lower limb function following 6 weeks of non-weight bearing
NASA Astrophysics Data System (ADS)
MacIntyre, Donna L.; Eng, Janice J.; Allen, Trevor J.
2005-05-01
Skeletal muscle weakness and atrophy occur following an extended period of decreased use, including space flight and limb unloading. It is also likely that affected muscles will be susceptible to a re-loading injury when they begin return to earth or weight bearing. However, there is a paucity of literature evaluating the response of human unloaded muscle to exercise and return to activity. The purpose of this pilot study was to evaluate the soreness, function and strength response of muscle to re-loading in seven patients who were non-weight bearing for 6 weeks, compared to five healthy subjects. Function improved significantly over time for the patients but was still less than the healthy subjects over 12 weeks of physiotherapy. Concentric quadriceps muscle strength increased significantly over time for the patients. There was considerable variability in the patients' reports of muscle soreness but there were no significant changes over time or between groups.
Compatibility of the totally replaced hip. Reduction of wear by amorphous diamond coating.
Santavirta, Seppo
2003-12-01
Particulate wear debris in totally replaced hips causes adverse local host reactions. The extreme form of such a reaction, aggressive granulomatosis, was found to be a distinct condition and different from simple aseptic loosening. Reactive and adaptive tissues around the totally replaced hip were made of proliferation of local fibroblast like cells and activated macrophages. Methylmethacrylate and high-molecular-weight polyethylene were shown to be essentially immunologically inert implant materials, but in small particulate form functioned as cellular irritants initiating local biological reactions leading to loosening of the implants. Chromium-cobalt-molybdenum is the most popular metallic implant material; it is hard and tough, and the bearings of this metal are partially self-polishing. In total hip implants, prerequisites for longevity of the replaced hip are good biocompatibility of the materials and sufficient tribological properties of the bearings. The third key issue is that the bearing must minimize frictional shear at the prosthetic bone-implant interface to be compatible with long-term survival. Some of the approaches to meet these demands are alumina-on-alumina and metal-on-metal designs, as well as the use of highly crosslinked polyethylene for the acetabular component. In order to avoid the wear-based deleterious properties of the conventional total hip prosthesis materials or coatings, the present work included biological and tribological testing of amorphous diamond. Previous experiments had demonstrated that a high adhesion of tetrahedral amorphous carbon coatings to a substrate can be achieved by using mixing layers or interlayers. Amorphous diamond was found to be biologically inert, and simulator testing indicated excellent wear properties for conventional total hip prostheses, in which either the ball or both bearing surfaces were coated with hydrogen-free tetrahedral amorphous diamond films. Simulator testing with such total hip prostheses showed no measurable wear or detectable delamination after 15,000,000 test cycles corresponding to 15 years of clinical use. The present work clearly shows that wear is one of the basic problems with totally replaced hips. Diamond coating of the bearing surfaces appears to be an attractive solution to improve longevity of the totally replaced hip.
Wilson, George; Drust, Barry; Morton, James P; Close, Graeme L
2014-06-01
Professional jockeys are unique amongst weight-making athletes given that they face the requirement to make weight daily. Furthermore, unlike other weight-limited sports, jockeys who have engaged in rapid weight loss cannot fully rehydrate prior to competition because post-race weight must not be more than 1 kg different to their pre-race weight. As such, jockeys have reported a variety of acute and chronic methods to make weight that include sporadic eating, caloric restriction, diuretics, laxatives, vomiting and fluid restriction as well as regular use of sweat suits and saunas. Typical daily energy intake is reported to be 6.5-8.0 MJ (carbohydrate 3 g kg(-1) body weight, fat 1 g kg(-1) body weight, protein 1 g kg(-1) body weight) and jockeys also exhibit micronutrient deficiencies that include vitamin D and calcium. Accordingly, the combination of low macronutrient, micronutrient and fluid intake results in poor bone health and abnormal mood profiles and can also impair simulated riding performance. Although the energy cost of real-world training and racing is unknown, energy expenditure during simulated race riding and total daily energy expenditure was 0.20 and 11.0 MJ, respectively. Such estimates of energy expenditure are considerably lower than that of other sports and suggest that conventional sports nutrition guidelines may not be applicable to the elite jockey. Furthermore, the use of daily diets that emphasise a high-protein and reduced carbohydrate intake (in the form of six small daily meals) in combination with structured exercise has also proven effective in reducing body mass and maintaining target racing weight. In this regard, available data suggest the need for those organisations responsible for jockey welfare to implement widespread educational programmes to assist in improving both the physical and mental well-being of professional jockeys. Given the high occupational risks associated with race riding (e.g. falls and bone fractures), future research should specifically target strategies to improve bone health through the use of structured weight-bearing exercise and correcting nutritional deficiencies.
Effects of simulated weightlessness and sympathectomy on maximum VO2 of male rats
NASA Technical Reports Server (NTRS)
Woodman, C. R.; Stump, C. S.; Beaulieu, S. M.; Rahman, Z.; Sebastian, L. A.
1989-01-01
The effects of simulated weightlessness (hind-limb suspension) and chemical sympathectomy (by repeated injections with guanethidine sulfate) on the maximum oxygen consumption (VO2 max) of female rats were investigated in rats assigned for 14 days to one of three groups: a head-down hind-limb suspension, a horizontal suspension with hind limbs weight bearing, or the caged control. The VO2 max values were assessed by having rats run on a treadmill enclosed in an airtight chamber. The hind-limb-suspended sympathectomized rats were found to exhibit shorter run times and lower mechanical efficiencies, compared to their presuspension values or the values from saline-injected suspended controls. On the other hand, the suspended sympathectomized rats did not demonstrate a decrease in the VO2 max values that was observed in saline-injected controls.
An automatic method for detecting sliding railway wheels and hot bearings using thermal imagery.
DOT National Transportation Integrated Search
2016-05-03
One of the most important safety-related tasks in the rail industry is early detection of defective rolling : stock components. Railway wheels and wheel bearings are two components prone to damage due to : their interactions with brakes and railway t...
Embedding Task-Based Neural Models into a Connectome-Based Model of the Cerebral Cortex
Ulloa, Antonio; Horwitz, Barry
2016-01-01
A number of recent efforts have used large-scale, biologically realistic, neural models to help understand the neural basis for the patterns of activity observed in both resting state and task-related functional neural imaging data. An example of the former is The Virtual Brain (TVB) software platform, which allows one to apply large-scale neural modeling in a whole brain framework. TVB provides a set of structural connectomes of the human cerebral cortex, a collection of neural processing units for each connectome node, and various forward models that can convert simulated neural activity into a variety of functional brain imaging signals. In this paper, we demonstrate how to embed a previously or newly constructed task-based large-scale neural model into the TVB platform. We tested our method on a previously constructed large-scale neural model (LSNM) of visual object processing that consisted of interconnected neural populations that represent, primary and secondary visual, inferotemporal, and prefrontal cortex. Some neural elements in the original model were “non-task-specific” (NS) neurons that served as noise generators to “task-specific” neurons that processed shapes during a delayed match-to-sample (DMS) task. We replaced the NS neurons with an anatomical TVB connectome model of the cerebral cortex comprising 998 regions of interest interconnected by white matter fiber tract weights. We embedded our LSNM of visual object processing into corresponding nodes within the TVB connectome. Reciprocal connections between TVB nodes and our task-based modules were included in this framework. We ran visual object processing simulations and showed that the TVB simulator successfully replaced the noise generation originally provided by NS neurons; i.e., the DMS tasks performed with the hybrid LSNM/TVB simulator generated equivalent neural and fMRI activity to that of the original task-based models. Additionally, we found partial agreement between the functional connectivities using the hybrid LSNM/TVB model and the original LSNM. Our framework thus presents a way to embed task-based neural models into the TVB platform, enabling a better comparison between empirical and computational data, which in turn can lead to a better understanding of how interacting neural populations give rise to human cognitive behaviors. PMID:27536235
How preschoolers and adults represent their joint action partner's behavior.
Sacheli, Lucia Maria; Meyer, M; Hartstra, E; Bekkering, H; Hunnius, S
2017-10-24
We investigated the cognitive mechanisms underlying turn-taking joint action in 42-month-old children (Experiment 1) and adults (Experiment 2) using a behavioral task of dressing a virtual bear together. We aimed to investigate how participants represent a partners' behavior, i.e., in terms of specific action kinematics or of action effects. The bear was dressed by pressing a smaller and a bigger button. In the Action-response task, instructions asked participants to respond to the partner by pressing the same or opposite button; in the Action-effect task they had to respond to the partner's action effect by dressing the bear with the lacking part of the clothing, which in some cases implied pressing the same button and in other cases implied pressing the opposite button. In 50% of the trials, the partner's association between each button and the ensuing effect (dressing the bear with t-shirt or pants) was reversed, while it never changed for participants. Both children and adults showed no effect of physical congruency of actions, but showed impaired performance in the Action-effect task if their partner achieved her effect through a different action-effect association than their own. These results suggest that, when encoding their partner's actions, agents are influenced by action-effect associations that they learnt through their own experience. While interference led to overt errors in children, it caused longer reaction times in adults, suggesting that a flexible cognitive control (that is still in development in young children) is required to take on the partner's perspective.
Code of Federal Regulations, 2011 CFR
2011-01-01
... otherwise make any marking device containing any official mark or simulation thereof, or any label bearing any such mark or simulation, without the written authority therefor of the Administrator. However... legend shown in Figure 5 of § 381.102 or any simulation of that legend. (1) The certificate is a Food...
Code of Federal Regulations, 2010 CFR
2010-01-01
... otherwise make any marking device containing any official mark or simulation thereof, or any label bearing any such mark or simulation, without the written authority therefor of the Administrator. However... legend shown in Figure 5 of § 381.102 or any simulation of that legend. (1) The certificate is a Food...
Code of Federal Regulations, 2012 CFR
2012-01-01
... otherwise make any marking device containing any official mark or simulation thereof, or any label bearing any such mark or simulation, without the written authority therefor of the Administrator. However... legend shown in Figure 5 of § 381.102 or any simulation of that legend. (1) The certificate is a Food...
Code of Federal Regulations, 2013 CFR
2013-01-01
... otherwise make any marking device containing any official mark or simulation thereof, or any label bearing any such mark or simulation, without the written authority therefor of the Administrator. However... legend shown in Figure 5 of § 381.102 or any simulation of that legend. (1) The certificate is a Food...
Code of Federal Regulations, 2014 CFR
2014-01-01
... otherwise make any marking device containing any official mark or simulation thereof, or any label bearing any such mark or simulation, without the written authority therefor of the Administrator. However... legend shown in Figure 5 of § 381.102 or any simulation of that legend. (1) The certificate is a Food...
NASA Technical Reports Server (NTRS)
McDonald, P. Vernon; Newman, Dava
1999-01-01
The empirical investigation of extravehicular activity (EVA) mass handling conducted on NASA's Precision Air-Bearing Floor led to a Phase I SBIR from JSC. The purpose of the SBIR was to design an innovative system for evaluating space suit mobility and stability in conditions that simulate EVA on the surface of the Moon or Mars. The approach we used to satisfy the Phase I objectives was based on a structured methodology for the development of human-systems technology. Accordingly the project was broken down into a number of tasks and subtasks. In sequence, the major tasks were: 1) Identify missions and tasks that will involve EVA and resulting mobility requirements in the near and long term; 2) Assess possible methods for evaluating mobility of space suits during field-based EVA tests; 3) Identify requirements for behavioral evaluation by interacting with NASA stakeholders;.4) Identify necessary and sufficient technology for implementation of a mobility evaluation system; and 5) Prioritize and select technology solutions. The work conducted in these tasks is described in this final volume of the series on EVA mass handling. While prior volumes in the series focus on novel data-analytic techniques, this volume addresses technology that is necessary for minimally intrusive data collection and near-real-time data analysis and display.
Li, Sha; Tan, Hor Yue; Wang, Ning; Hong, Ming; Li, Lei; Cheung, Fan; Feng, Yibin
2016-01-01
Bear bile has been a well-known Chinese medicine for thousands of years. Because of the endangered species protection, the concept on substitutes for bear bile was proposed decades ago. Based on their chemical composition and pharmacologic actions, artificial bear bile, bile from other animals, synthetic compounds, and medicinal plants may be the promising candidates to replace bear bile for the similar therapeutic purpose. Accumulating research evidence has indicated that these potential substitutes for bear bile have displayed the same therapeutic effects as bear bile. However, stopping the use of bear bile is a challenging task. In this review, we extensively searched PubMed and CNKI for literatures, focusing on comparative studies between bear bile and its substitutes for the treatment of liver diseases. Recent research progress in potential substitutes for bear bile in the last decade is summarized, and a strategy for the use of substitutes for bear bile is discussed carefully. PMID:27087822
Effects of Alcohol on Performance on a Distraction Task During Simulated Driving
Allen, Allyssa J.; Meda, Shashwath A.; Skudlarski, Pawel; Calhoun, Vince; Astur, Robert; Ruopp, Kathryn C.; Pearlson, Godfrey D.
2009-01-01
Background Prior studies report that accidents involving intoxicated drivers are more likely to occur during performance of secondary tasks. We studied this phenomenon, using a dual-task paradigm, involving performance of a visual oddball (VO) task while driving in an alcohol challenge paradigm. Previous functional MRI (fMRI) studies of the VO task have shown activation in the anterior cingulate, hippocampus, and prefrontal cortex. Thus, we predicted dose-dependent decreases in activation of these areas during VO performance. Methods Forty healthy social drinkers were administered 3 different doses of alcohol, individually tailored to their gender and weight. Participants performed a VO task while operating a virtual reality driving simulator in a 3T fMRI scanner. Results Analysis showed a dose-dependent linear decrease in Blood Oxygen Level Dependent activation during task performance, primarily in hippocampus, anterior cingulate, and dorsolateral prefrontal areas, with the least activation occurring during the high dose. Behavioral analysis showed a dose-dependent linear increase in reaction time, with no effects associated with either correct hits or false alarms. In all dose conditions, driving speed decreased significantly after a VO stimulus. However, at the high dose this decrease was significantly less. Passenger-side line crossings significantly increased at the high dose. Conclusions These results suggest that driving impairment during secondary task performance may be associated with alcohol-related effects on the above brain regions, which are involved with attentional processing/decision-making. Drivers with high blood alcohol concentrations may be less able to orient or detect novel or sudden stimuli during driving. PMID:19183133
NASA Astrophysics Data System (ADS)
Rybus, Tomasz; Seweryn, Karol
2016-03-01
All devices designed to be used in space must be thoroughly tested in relevant conditions. For several classes of devices the reduced gravity conditions are the key factor. In early stages of development and later due to financial reasons, the tests need to be done on Earth. However, in Earth conditions it is impossible to obtain a different gravity field independent on all linear and rotational spatial coordinates. Therefore, various test-bed systems are used, with their design driven by the device's specific needs. One of such test-beds are planar air-bearing microgravity simulators. In such an approach, the tested objects (e.g., manipulators intended for on-orbit operations or vehicles simulating satellites in a close formation flight) are mounted on planar air-bearings that allow almost frictionless motion on a flat surface, thus simulating microgravity conditions in two dimensions. In this paper we present a comprehensive review of research activities related to planar air-bearing microgravity simulators, demonstrating achievements of the most active research groups and describing newest trends and ideas, such as tests of landing gears for low-g bodies. Major design parameters of air-bearing test-beds are also reviewed and a list of notable existing test-beds is presented.
Tapered Roller Bearing Damage Detection Using Decision Fusion Analysis
NASA Technical Reports Server (NTRS)
Dempsey, Paula J.; Kreider, Gary; Fichter, Thomas
2006-01-01
A diagnostic tool was developed for detecting fatigue damage of tapered roller bearings. Tapered roller bearings are used in helicopter transmissions and have potential for use in high bypass advanced gas turbine aircraft engines. A diagnostic tool was developed and evaluated experimentally by collecting oil debris data from failure progression tests conducted using health monitoring hardware. Failure progression tests were performed with tapered roller bearings under simulated engine load conditions. Tests were performed on one healthy bearing and three pre-damaged bearings. During each test, data from an on-line, in-line, inductance type oil debris sensor and three accelerometers were monitored and recorded for the occurrence of bearing failure. The bearing was removed and inspected periodically for damage progression throughout testing. Using data fusion techniques, two different monitoring technologies, oil debris analysis and vibration, were integrated into a health monitoring system for detecting bearing surface fatigue pitting damage. The data fusion diagnostic tool was evaluated during bearing failure progression tests under simulated engine load conditions. This integrated system showed improved detection of fatigue damage and health assessment of the tapered roller bearings as compared to using individual health monitoring technologies.
A novel model to assess lamellar signaling relevant to preferential weight bearing in the horse.
Gardner, A K; van Eps, A W; Watts, M R; Burns, T A; Belknap, J K
2017-03-01
Supporting limb laminitis (SLL) is a devastating sequela to severe unilateral lameness in equine patients. The manifestation of SLL, which usually only affects one limb, is unpredictable and the etiology is unknown. A novel, non-painful preferential weight bearing model designed to mimic the effects of severe unilateral forelimb lameness was developed to assess lamellar signaling events in the supporting limb (SL). A custom v-shaped insert was attached to the shoe of one forelimb to prevent normal weight bearing and redistribute weight onto the SL. Testing of the insert using a custom scale platform built into the floor of stocks confirmed increased distribution of weight on the SL compared with the unloaded forelimb (UL) and the contralateral (CH) and ipsilateral (IH) hind limbs in six Standardbred horses. In a second part of the study, eight healthy Standardbred horses were fitted with the insert and tied with consistent monitoring and free access to hay and water for 48 h, after which the lamellae were harvested. Real-time qPCR was performed to assess lamellar mRNA concentrations of inflammatory genes and immunoblotting and immunofluorescence were performed to assess lamellar protein concentration and cellular localization of hypoxia-related proteins, respectively. Lamellar mRNA concentrations of inflammatory signaling proteins did not differ between SL and either CH or IH samples. HIF-1α concentrations were greater (P < 0.05) in the SL compared to the CH. This work establishes an experimental model to study preferential weight bearing and initial results suggest that lamellar hypoxia may occur in the SL. Copyright © 2017. Published by Elsevier Ltd.
Sclerostin antibody inhibits skeletal deterioration in mice exposed to partial weight-bearing
NASA Astrophysics Data System (ADS)
Spatz, J. M.; Ellman, R.; Cloutier, A. M.; Louis, L.; van Vliet, M.; Dwyer, D.; Stolina, M.; Ke, H. Z.; Bouxsein, M. L.
2017-02-01
Whereas much is known regarding the musculoskeletal responses to full unloading, little is known about the physiological effects and response to pharmacological agents in partial unloading (e.g. Moon and Mars) environments. To address this, we used a previously developed ground-based model of partial weight-bearing (PWB) that allows chronic exposure to reduced weight-bearing in mice to determine the effects of murine sclerostin antibody (SclAbII) on bone microstructure and strength across different levels of mechanical unloading. We hypothesize that treatment with SclAbII would improve bone mass, microarchitecture and strength in all loading conditions, but that there would be a greater skeletal response in the normally loaded mice than in partially unloaded mice suggesting the importance of combined countermeasures for exploration-class long duration spaceflight missions. Eleven-week-old female mice were assigned to one of four loading groups: normal weight-bearing controls (CON) or weight-bearing at 20% (PWB20), 40% (PWB40) or 70% (PWB70) of normal. Mice in each group received either SclAbII (25 mg/kg) or vehicle (VEH) via twice weekly subcutaneous injection for 3 weeks. In partially-unloaded VEH-treated groups, leg BMD decreased -5 to -10% in a load-dependent manner. SclAbII treatment completely inhibited bone deterioration due to PWB, with bone properties in SclAbII-treated groups being equal to or greater than those of CON, VEH-treated mice. SclAbII treatment increased leg BMD from +14 to +18% in the PWB groups and 30 ± 3% in CON (p < 0.0001 for all). Trabecular bone volume, assessed by μCT at the distal femur, was lower in all partially unloaded VEH-treated groups vs. CON-VEH (p < 0.05), and was 2-3 fold higher in SclAbII-treated groups (p < 0.001). Midshaft femoral strength was also significantly higher in SclAbII vs. VEH-groups in all-loading conditions. These results suggest that greater weight bearing leads to greater benefits of SclAbII on bone mass, particularly in the trabecular compartment. Altogether, these results demonstrate the efficacy of sclerostin antibody therapy in preventing astronaut bone loss during terrestrial solar system exploration.
Sclerostin antibody inhibits skeletal deterioration in mice exposed to partial weight-bearing.
Spatz, J M; Ellman, R; Cloutier, A M; Louis, L; van Vliet, M; Dwyer, D; Stolina, M; Ke, H Z; Bouxsein, M L
2017-02-01
Whereas much is known regarding the musculoskeletal responses to full unloading, little is known about the physiological effects and response to pharmacological agents in partial unloading (e.g. Moon and Mars) environments. To address this, we used a previously developed ground-based model of partial weight-bearing (PWB) that allows chronic exposure to reduced weight-bearing in mice to determine the effects of murine sclerostin antibody (SclAbII) on bone microstructure and strength across different levels of mechanical unloading. We hypothesize that treatment with SclAbII would improve bone mass, microarchitecture and strength in all loading conditions, but that there would be a greater skeletal response in the normally loaded mice than in partially unloaded mice suggesting the importance of combined countermeasures for exploration-class long duration spaceflight missions. Eleven-week-old female mice were assigned to one of four loading groups: normal weight-bearing controls (CON) or weight-bearing at 20% (PWB20), 40% (PWB40) or 70% (PWB70) of normal. Mice in each group received either SclAbII (25mg/kg) or vehicle (VEH) via twice weekly subcutaneous injection for 3 weeks. In partially-unloaded VEH-treated groups, leg BMD decreased -5 to -10% in a load-dependent manner. SclAbII treatment completely inhibited bone deterioration due to PWB, with bone properties in SclAbII-treated groups being equal to or greater than those of CON, VEH-treated mice. SclAbII treatment increased leg BMD from +14 to +18% in the PWB groups and 30 ± 3% in CON (p< 0.0001 for all). Trabecular bone volume, assessed by μCT at the distal femur, was lower in all partially unloaded VEH-treated groups vs. CON-VEH (p< 0.05), and was 2-3 fold higher in SclAbII-treated groups (p< 0.001). Midshaft femoral strength was also significantly higher in SclAbII vs. VEH-groups in all-loading conditions. These results suggest that greater weight bearing leads to greater benefits of SclAbII on bone mass, particularly in the trabecular compartment. Altogether, these results demonstrate the efficacy of sclerostin antibody therapy in preventing astronaut bone loss during terrestrial solar system exploration. Copyright © 2017 The Committee on Space Research (COSPAR). Published by Elsevier Ltd. All rights reserved.
Chen, Wei; Liu, Bo; Lv, Hongzhi; Su, Yanling; Chen, Xiao; Zhu, Yanbin; Du, Chenguang; Zhang, Xiaolin; Zhang, Yingze
2017-09-01
Early post-operative exercise and weight-bearing activities are found to improve the functional recovery of patients with displaced intra-articular calcaneal fractures (DIACFs). We hypothesized that early functional exercise after surgery might have a secondary reduction effect on the subtalar joint, in particular the smaller fracture fragments that were not fixed firmly. A prospective study was conducted to verify this hypothesis. From December 2012 to September 2013, patients with unilateral DIACFs were enrolled and received a treatment consisting of percutaneous leverage and minimally invasive fixation. After surgery, patients in the study group started exercising on days two to three, using partial weight bearing starting week three, and full weight bearing starting week 12. Patients in the control group followed a conventional post-operative protocol of partial weight bearing after week six and full weight bearing after the bone healed. Computed tomography (CT) scanning was performed at post-operative day one, week four, week eight, and week 12 to reconstruct coronal, sagittal, and axial images, on which the maximal residual displacements of the fractures were measured. Function was evaluated using the American Orthopaedic Foot and Ankle Society (AOFAS) scoring scale at the 12th post-operative month. Twenty-eight patients in the study group and 32 in the control group were followed up for more than 12 months; their data were collected and used for the final analysis. Repeated-measures analysis of variance (ANOVA) of the maximal residual displacements of the fracture measured on CT images revealed significant differences between the study and the control groups. There were interaction effects between group and time point. Except for the first time point, the differences between the groups at all studied time points were significant. In the study group, the differences between all studied time points were significant. Strong correlations were observed between the AOFAS score at post-operative month 12 and the maximal residual displacement of the fractures on the CT images at postoperative week 12. Early functional exercise and weight bearing activity can smooth and shape the subtalar joint and reduce the residual displacement of the articular surface, improving functional recovery of the affected foot. Therefore, early rehabilitation functional exercise can be recommended in clinical practice.
NASA Astrophysics Data System (ADS)
Arirajan, K. A.; Chockalingam, K.; Vignesh, C.
2018-04-01
Implants are the artificial parts to replace the missing bones or joints in human anatomy to give mechanical support. Hip joint replacement is an important issue in orthopaedic surgery. The main concern limiting the long-run success of the total hip replacement is the limited service life. Hip replacement technique is widely used in replacing the femur head and acetabular cup by materials that are highly biocompatible. The success of the artificial hip replacement depends upon proper material selection, structure, and shape of the hip prosthesis. Many orthopaedic analyses have been tried with different materials, but ended with partial success on the application side. It is a critical task for selecting the best material pair in the hip prosthesis design. This work develops the finite element analysis of an artificial hip implant to study highest von Mises stress, contact pressure and elastic strain occurs for the dissimilar material combination. The different bearing couple considered for the analysis are Metal on Metal, Metal on Plastic, Metal on Ceramic, Ceramic on Plastic, Ceramic on Ceramic combinations. The analysis is carried out at different static positions of a human (i.e) standing, sitting. The results reveals that the combination with metal in contact with plastic (i.e) Titanium femoral head paired with Ultra High Molecular Weight Poly Ethylene acetabular cup reduces maximum von Mises stress and also it gives lowest contact pressure than other combination of bearing couples.
Periyasamy, Kuppusamy; Baskaran, Kuppusamy; Ilakkia, Aruldass; Vanitha, Kalappan; Selvaraj, Sundaramoorthy; Sakthisekaran, Dhanapal
2015-02-01
The aim of the present study was to assess the chemopreventive and chemotherapeutic efficacy of tangeretin on DMBA-induced oxidative stress in breast cancer-bearing Sprague-Dawley rats. In this study, the experimental animals were divided into five groups of six animals each. Group I was control, Group II was DMBA-induced breast cancer-bearing rats, Group III was tangeretin pre-treated (50 mg/kg body weight for 30 days orally) breast cancer-bearing animals, Group IV was tangeretin post-treated (50 mg/kg body weight for 30 days orally) and Group V was tangeretin (50 mg/kg body weight) alone treated animals. We have observed the general characteristics of cancer, oxidative stress markers, breast cancer marker, antioxidants and histopathological changes in the experimental animals. We have recorded the body weight, tumor weights, tumor volume and antitumor activity of tangeretin in the experimental animals. Oxidative stress markers, like NO and LPO, and breast cancer marker CEA levels were significantly (p < 0.001, p < 0.05) increased as well as the antioxidants like SOD, CAT, GPx, GST, GSH, ascorbic acid and α-tocopherol were found to be significantly (p < 0.05) decreased in cancer-bearing Group II animals. Whereas, the enzymic and non-enzymic antioxidant levels were found to be significantly decreased in cancer-bearing animals. However, in tangeretin pre-treated and post- treated animals, the levels of antioxidants and breast cancer marker were found to be significantly (p < 0.05) reduced with a concomitant increase in the activities of the antioxidants (p < 0.05). In tangeretin alone treated Group V animals, no significant changes were observed in the levels of antioxidants and breast cancer marker. These results were adequately supported by the histopathological studies in the mammary tissues of the experimental animals. From this study, we conclude that the administration of tangeretin was found to be beneficial against DMBA-induced oxidative stress in breast cancer-bearing animals. Hence, we strongly suggest that tangeretin is effective and efficient candidate for the treatment of experimental breast cancer.
Hoch, Matthew C.; Farwell, Kelley E.; Gaven, Stacey L.; Weinhandl, Joshua T.
2015-01-01
Context People with chronic ankle instability (CAI) exhibit less weight-bearing dorsiflexion range of motion (ROM) and less knee flexion during landing than people with stable ankles. Examining the relationship between dorsiflexion ROM and landing biomechanics may identify a modifiable factor associated with altered kinematics and kinetics during landing tasks. Objective To examine the relationship between weight-bearing dorsiflexion ROM and single-legged landing biomechanics in persons with CAI. Design Cross-sectional study. Setting Laboratory. Patients or Other Participants Fifteen physically active persons with CAI (5 men, 10 women; age = 21.9 ± 2.1 years, height = 168.7 ± 9.0 cm, mass = 69.4 ± 13.3 kg) participated. Intervention(s) Participants performed dorsiflexion ROM and single-legged landings from a 40-cm height. Sagittal-plane kinematics of the lower extremity and ground reaction forces (GRFs) were captured during landing. Main Outcome Measure(s) Static dorsiflexion was measured using the weight-bearing–lunge test. Kinematics of the ankle, knee, and hip were observed at initial contact, maximum angle, and sagittal displacement. Sagittal displacements of the ankle, knee, and hip were summed to examine overall sagittal displacement. Kinetic variables were maximum posterior and vertical GRFs normalized to body weight. We used Pearson product moment correlations to evaluate the relationships between dorsiflexion ROM and landing biomechanics. Correlations (r) were interpreted as weak (0.00–0.40), moderate (0.41–0.69), or strong (0.70–1.00). The coefficient of determination (r2) was used to determine the amount of explained variance among variables. Results Static dorsiflexion ROM was moderately correlated with maximum dorsiflexion (r = 0.49, r2 = 0.24), ankle displacement (r = 0.47, r2 = 0.22), and total displacement (r = 0.67, r2 = 0.45) during landing. Dorsiflexion ROM measured statically and during landing demonstrated moderate to strong correlations with maximum knee (r = 0.69–0.74, r2 = 0.47–0.55) and hip (r = 0.50–0.64, r2 = 0.25–0.40) flexion, hip (r = 0.53–0.55, r2 = 0.28–0.30) and knee (r = 0.53–0.70, r2 = 0.28–0.49) displacement, and vertical GRF (−0.47– −0.50, r2 = 0.22–0.25). Conclusions Dorsiflexion ROM was moderately to strongly related to sagittal-plane kinematics and maximum vertical GRF during single-legged landing in persons with CAI. Persons with less dorsiflexion ROM demonstrated a more erect landing posture and greater GRF. PMID:26067428
Filtration effects on ball bearing life and condition in a contaminated lubricant
NASA Technical Reports Server (NTRS)
Loewenthal, S. H.; Moyer, D. W.
1978-01-01
Ball bearings were fatigue tested with a noncontaminated lubricant and with a contaminated lubricant under four levels of filtration. The test filters had absolute particle removal ratings of 3, 30, 49, and 105 microns. Aircraft turbine engine contaminants were injected into the filter's supply line at a constant rate of 125 milligrams per bearing hour. Bearing life and running track condition generally improved with finer filtration. The experimental lives of 3 and 30 micron filter bearings were statistically equivalent, approaching those obtained with the noncontaminated lubricant bearings. Compared to these bearings, the lives of the 49 micron bearings were statistically lower. The 105 micron bearings experienced gross wear. The degree of surface distress, weight loss, and probable failure mode were dependent on filtration level, with finer filtration being clearly beneficial.
Hydrostatic Bearing Pad Maximum Load and Overturning Conditions for the 70-meter Antenna
NASA Technical Reports Server (NTRS)
Mcginness, H. D.
1985-01-01
The reflector diameters of the 64-m antennas were increased to 70-m. In order to evaluate the minimum film thickness of the hydrostatic bearing which supports the antenna weight, it is first necessary to have a good estimation of the maximum operational load on the most heavily loaded bearing pad. The maximum hydrostatic bearing load is shown to be sufficiently small and the ratios of stabilizing to over turning moments are ample.
Effects of different modes of exercise on appetite and appetite-regulating hormones.
Kawano, Hiroshi; Mineta, Mayuko; Asaka, Meiko; Miyashita, Masashi; Numao, Shigeharu; Gando, Yuko; Ando, Takafumi; Sakamoto, Shizuo; Higuchi, Mitsuru
2013-07-01
The present study determined the changes in appetite and appetite-regulating gut hormones during and following bouts of both rope skipping exercise (weight-bearing) and bicycle ergometer exercise (non-weight-bearing). After a 12-h fast, 15 young men (mean ± SD, age 24.4 ± 1.7 yrs, maximal oxygen uptake 47.0 ± 6.5 mL/kg/min) participated in three 160 min trials: (1) rope skipping exercise (295 ± 40 kcal, 3 sets × 10 min with 5-min interval, then rested for 120 min); (2) bicycle ergometer exercise (288 ± 36 kcal, 3 sets × 10 min with 5-min interval, then rested for 120 min); (3) control (rested for 160 min). Ratings of perceived hunger and acylated ghrelin were suppressed and total peptide YY (PYY) were increased during and immediately after exercise in both exercise trials, but glucagon liked peptide-1 was not changed. Furthermore, suppressed hunger during rope skipping exercise was greater than that during bicycle ergometer exercise, but there were no differences in acylated ghrelin and total PYY. These results indicate that weight-bearing exercise has a greater exercise-induced appetite suppressive effect compared with non-weight-bearing exercise, and both forms of exercise lowered acylated ghrelin and increased total PYY, but the changes did not differ significantly between exercise modes. Copyright © 2013 Elsevier Ltd. All rights reserved.
Factors affecting bone mineral mass loss after lower-limb fractures in a pediatric population.
Ceroni, Dimitri; Martin, Xavier; Kherad, Omar; Salvo, Davide; Dubois-Ferrière, Victor
2015-06-01
The purpose of this study was to assess the effects of the durations of cast immobilization and non-weight-bearing periods, and decreases in vigorous physical activity (VPA) on bone mineral parameters in a pediatric population treated for a lower-limb fracture. Fifty children and teenagers who had undergone a cast-mediated immobilization for a leg or ankle fracture were prospectively recruited. The durations of cast immobilization and non-weight-bearing periods were recorded for each participant. Dual-energy x-ray absorptiometry scans were performed at the time of fracture treatment (baseline) and at cast removal. Physical activity during cast immobilization was assessed using accelerometers. A strong negative correlation was found between the total duration of cast immobilization and decreases in both calcaneal bone mineral density (BMD) (r=-0.497) and total lower-limb bone mineral content (BMC) (r=-0.405). A strong negative correlation was also noted between the durations of the non-weight-bearing periods and alterations in calcaneal BMD (r=-0.420). No apparent correlations were found between lower BMD and BMC and decreased VPA. Bone mineral loss was correlated to the total duration of cast immobilization for all measurement sites on the affected leg, whereas it was only correlated to the durations of non-weight-bearing periods for calcaneal BMD and total lower-limb BMC. However, no correlations were noted between bone mineral loss and decreased VPA.
Production of iron from metallurgical waste
Hendrickson, David W; Iwasaki, Iwao
2013-09-17
A method of recovering metallic iron from iron-bearing metallurgical waste in steelmaking comprising steps of providing an iron-bearing metallurgical waste containing more than 55% by weight FeO and FeO equivalent and a particle size of at least 80% less than 10 mesh, mixing the iron-bearing metallurgical waste with a carbonaceous material to form a reducible mixture where the carbonaceous material is between 80 and 110% of the stoichiometric amount needed to reduce the iron-bearing waste to metallic iron, and as needed additions to provide a silica content between 0.8 and 8% by weight and a ratio of CaO/SiO.sub.2 between 1.4 and 1.8, forming agglomerates of the reducible mixture over a hearth material layer to protect the hearth, heating the agglomerates to a higher temperature above the melting point of iron to form nodules of metallic iron and slag material from the agglomerates by melting.
NASA Astrophysics Data System (ADS)
Abrahamsen, Asger Bech; Natarajan, Anand
2016-09-01
The drivetrain of a 10 MW wind turbine has been designed as a direct drive transmission with a superconducting generator mounted in front of the hub and connected to the main frame through a King-pin stiff assembly by DNV-GL. The aeroelastic design loads of such an arrangement are evaluated based on the thrust and bending moments at the main bearing, both for ultimate design and in fatigue. It is found that the initial superconductor generator weight of 363 tons must be reduced by 25% in order not to result in higher extreme loads on main and yaw bearing than the reference10 MW geared reference drive train. A weight reduction of 50% is needed in order to maintain main bearing fatigue damage equivalent to the reference drive train. Thus a target mass of front mounted superconducting direct drive generators is found to be between 183-272 tons.
Processing of probabilistic information in weight perception and motor prediction.
Trampenau, Leif; van Eimeren, Thilo; Kuhtz-Buschbeck, Johann
2017-02-01
We studied the effects of probabilistic cues, i.e., of information of limited certainty, in the context of an action task (GL: grip-lift) and of a perceptual task (WP: weight perception). Normal subjects (n = 22) saw four different probabilistic visual cues, each of which announced the likely weight of an object. In the GL task, the object was grasped and lifted with a pinch grip, and the peak force rates indicated that the grip and load forces were scaled predictively according to the probabilistic information. The WP task provided the expected heaviness related to each probabilistic cue; the participants gradually adjusted the object's weight until its heaviness matched the expected weight for a given cue. Subjects were randomly assigned to two groups: one started with the GL task and the other one with the WP task. The four different probabilistic cues influenced weight adjustments in the WP task and peak force rates in the GL task in a similar manner. The interpretation and utilization of the probabilistic information was critically influenced by the initial task. Participants who started with the WP task classified the four probabilistic cues into four distinct categories and applied these categories to the subsequent GL task. On the other side, participants who started with the GL task applied three distinct categories to the four cues and retained this classification in the following WP task. The initial strategy, once established, determined the way how the probabilistic information was interpreted and implemented.
Ohta, Yoichi; Ishii, Yasumitsu; Ikudome, Sachi; Nakamoto, Hiroki
2014-02-01
The effects of weighted bat warm-up on adjustment of upper limb muscle activity were investigated during baseball bat swinging under dynamic conditions that require a spatial and temporal adjustment of the swinging to hit a moving target. Seven male college baseball players participated in this study. Using a batting simulator, the task was to swing the standard bat coincident with the arrival timing and position of a moving target after three warm-up swings using a standard or weighted bat. There was no significant effect of weighted bat warm-up on muscle activity before impact associated with temporal or spatial movement corrections. However, lower inhibition of the extensor carpi ulnaris muscle activity was observed in a velocity-changed condition in the weighted bat warm-up, as compared to a standard bat warm-up. It is suggested that weighted bat warm-up decreases the adjustment ability associated with inhibition of muscle activation under movement correction conditions.
Code of Federal Regulations, 2011 CFR
2011-01-01
... marking device containing any official mark or simulation thereof, or any label bearing any such mark or simulation, without the written authority therefor of the Administrator. However, when any such sample label... inspection legend, or simulation thereof, shown in § 312.2(a), § 312.3(a) (only the legend appropriate for...
Code of Federal Regulations, 2013 CFR
2013-01-01
... marking device containing any official mark or simulation thereof, or any label bearing any such mark or simulation, without the written authority therefor of the Administrator. However, when any such sample label... inspection legend, or simulation thereof, shown in § 312.2(a), § 312.3(a) (only the legend appropriate for...
Code of Federal Regulations, 2014 CFR
2014-01-01
... marking device containing any official mark or simulation thereof, or any label bearing any such mark or simulation, without the written authority therefor of the Administrator. However, when any such sample label... inspection legend, or simulation thereof, shown in § 312.2(a), § 312.3(a) (only the legend appropriate for...
Code of Federal Regulations, 2010 CFR
2010-01-01
... marking device containing any official mark or simulation thereof, or any label bearing any such mark or simulation, without the written authority therefor of the Administrator. However, when any such sample label... inspection legend, or simulation thereof, shown in § 312.2(a), § 312.3(a) (only the legend appropriate for...
Code of Federal Regulations, 2012 CFR
2012-01-01
... marking device containing any official mark or simulation thereof, or any label bearing any such mark or simulation, without the written authority therefor of the Administrator. However, when any such sample label... inspection legend, or simulation thereof, shown in § 312.2(a), § 312.3(a) (only the legend appropriate for...
Marcinik, E J; Hodgdon, J A; Englund, C E; O'Brien, J J
1987-01-01
Pre- and post-physiological data were collected on 57 Navy men (mean age = 19.5 years) who participated in either circuit weight training/continuous run (CWT/CR) (N = 31) or circuit weight training/interval run (CWT/IR) (N = 26) programs. Measured variables included 4 measures of upper torso dynamic strength (one repetition maximum [1 RM] for arm curl, bench press, shoulder press, and lat pull-down); two measures of lower torso dynamic strength (1 RM) for knee extension and leg press); one measure of power (number of revolutions completed on an arm ergometer (Monark) at maximum drag); three measures of muscular endurance (number of repetitions at 60% 1 RM for bench press and leg press and maximal number of bent-knee sit-ups in 120 s); one stamina measure (time to exhaustion on a cycle ergometer (Monark) maximal work capacity [MWC] test; and three simulated shipboard tasks: manikin shoulder drag, open/secure a water tight door and paint bucket carry. Composite shipboard performance derived from the summed time (s) required to complete the three tasks was also calculated. Results show performance on the manikin shoulder drag and majority of evaluative fitness measures was significantly (p less than 0.05) enhanced following both circuit weight training/run formats. Significantly (p less than 0.05) higher values for shoulder press (F = 7.2), arm ergometer (F = 5.3), and sit-ups (F = 6.8) and lower values for leg press muscular endurance (F = 5.1) were observed in CWT/IR when compared to CWT/CR.(ABSTRACT TRUNCATED AT 250 WORDS)
A leakage-free resonance sparse decomposition technique for bearing fault detection in gearboxes
NASA Astrophysics Data System (ADS)
Osman, Shazali; Wang, Wilson
2018-03-01
Most of rotating machinery deficiencies are related to defects in rolling element bearings. Reliable bearing fault detection still remains a challenging task, especially for bearings in gearboxes as bearing-defect-related features are nonstationary and modulated by gear mesh vibration. A new leakage-free resonance sparse decomposition (LRSD) technique is proposed in this paper for early bearing fault detection of gearboxes. In the proposed LRSD technique, a leakage-free filter is suggested to remove strong gear mesh and shaft running signatures. A kurtosis and cosine distance measure is suggested to select appropriate redundancy r and quality factor Q. The signal residual is processed by signal sparse decomposition for highpass and lowpass resonance analysis to extract representative features for bearing fault detection. The effectiveness of the proposed technique is verified by a succession of experimental tests corresponding to different gearbox and bearing conditions.
Tissue adaptations to gravitational stress - Newborn versus adult giraffes
NASA Technical Reports Server (NTRS)
Hargens, Alan R; Gershuni, David H.; Danzig, Larry A.; Millard, Ronald W.; Pettersson, Knut
1988-01-01
Preliminary results on developmental alterations in load-bearing tissues of newborn and adult giraffes are presented. Attention is focused on vascular wall thickness in relation to local blood pressure, and on meniscal adaptations to increased load bearing in the developing giraffe. It is believed that the developing giraffe provides an excellent model for investigations of adaptive mechanisms of increased weight bearing.
Cryogenic Magnetic Bearing Test Facility (CMBTF)
NASA Technical Reports Server (NTRS)
1992-01-01
The Cryogenic Magnetic Bearing Test Facility (CMBTF) was designed and built to evaluate compact, lightweight magnetic bearings for use in the SSME's (space shuttle main engine) liquid oxygen and liquid hydrogen turbopumps. State of the art and tradeoff studies were conducted which indicated that a hybrid permanent magnet bias homopolar magnetic bearing design would be smaller, lighter, and much more efficient than conventional industrial bearings. A test bearing of this type was designed for the test rig for use at both room temperature and cryogenic temperature (-320 F). The bearing was fabricated from state-of-the-art materials and incorporated into the CMBTF. Testing at room temperature was accomplished at Avcon's facility. These preliminary tests indicated that this magnetic bearing is a feasible alternative to older bearing technologies. Analyses showed that the hybrid magnetic bearing is one-third the weight, considerably smaller, and uses less power than previous generations of magnetic bearings.
Study on properties of CFRP fabricated by VA-RTM process
NASA Astrophysics Data System (ADS)
Jeoung, Sun Kyoung; Hwang, Ye Jin; Lee, Hyun Wook; Son, Soon Keun; Kim, Hyung Sik; Ha, Jin Uk
2016-03-01
Carbon fiber reinforced plastics (CFRP) have a lot of attention from industry and academia due to its excellent mechanical property. It has been used for aircraft, automotive and so on, since it can replace metallic materials and reduce total weight with increased physical properties. However, the manufacturing process and the material cost are still challenging to be commercialized in the automotive market. Therefore, many researchers are trying to minimize materials and process cost for broadening their applications. In this study, thermoset epoxy resins were used for binder of CFRP. Epoxy resins were investigated in order to figure out optimized curing speed under vacuum assisted resin transfer molding (VARTM) processing condition. Mechanical properties of CFRP with different carbon fiber orientation and woven carbon fiber were compared to mathematically simulated results. In order to develop the application of automobile component, reliability tests of CFRP were carried out. Tensile strength of CFRP is increased when the orientation angle between fiber and axis of load was decreased (90°→ 0°). It is considered that epoxy and carbon fiber absorbed the tensile energy because the orientation of fiber and the load bearing are matched with axis direction. In addition, the CFRP automobile engine hood was fabricated by VARTM process. Drop weight impact tests (20kg & 100kg weight) were carried out in order to simulate crash performance of CFRP engine hoods.
Relationships Among Lower Body Strength, Power, and Performance of Functional Tasks
NASA Technical Reports Server (NTRS)
Ploutz-Snyder, Lori; Ryder, J.; Hackney, K.; Scott-Pandorf, M.; Redd, E.; Buxton, R.; Bloomberg, J.
2010-01-01
There is a large degree of variability among crewmembers with respect to decrements in muscle strength and power following long duration spaceflight, ranging from 0 to approx.30% reductions. The purpose of this study was to investigate the influence of varying decrements in lower body muscle strength and power (relative to body weight) on the performance of 2 occupationally relevant tasks (ladder climb and supine egress & walk). Seventeen participants with leg strength similar to US crewmembers performed a leg press power test, an isokinetic knee extension strength test and they were asked to complete the 2 functional tasks as quickly as possible. On additional test days the participants were asked to repeat the functional tasks under 3 conditions where a different external load was applied each time using a weighted suit in order to experimentally manipulate participants strength/body weight and power/body weight ratios. The weight in the suit ranged from 20-120% of body weight and was distributed in proportion to limb segment weights to minimize changes in center of gravity. The ladder task consisted of climbing 40 rungs on a ladder treadmill as fast as possible. The supine egress & walk task consisted of rising from a supine position and walking through an obstacle course. Results show a relatively linear relationship between strength/body weight and task time and power/body weight with task time such that the fastest performance times are associated with higher strength and power with about half the variance in task time is accounted for by a single variable (either strength or power). For the average person, a 20% reduction in power/body weight (from 18 to 14.4 W/kg) induces an increase (slowing) of about 10 seconds in the ladder climb task from 14 to 24 seconds (approx.70%) and a slowing of the supine egress & walk task from 14 to 21 seconds (approx.50%). Similar relationships were observed with strength/body weight and task performance. For the average person, a 20% reduction in strength/body weight (from 2.1 to 1.7 Nm/kg) resulted in a slowing of the ladder climb from 10.5 to 24 seconds (approx.128%) and a slowing of the supine egress & walk from 11 to 20 seconds (approx.82%). These data suggest that the single variable of either low body muscle strength or power, relative to body weight is predictive of about 50% of the variance in task performance time, and that considerable slowing in task performance is associated with relatively typical decrements in muscle performance seen with long duration spaceflight. The observation of a relatively linear relationship between strength/power and task time suggests that across the full spectrum of initial crew strengths and typical decrements in strength previously observed, that task performance would be expected to be slowed following long duration spaceflight. These data will be confirmed in actual spaceflight with subsequent studies.
NASA Astrophysics Data System (ADS)
Lyu, Mindong; Liu, Tao; Wang, Zixi; Yan, Shaoze; Jia, Xiaohong; Wang, Yuming
2018-05-01
Touchdown can make active magnetic bearings (AMB) unable to work, and bring severe damages to touchdown bearings (TDB). To resolve it, we presents a novel re-levitation method consisting of two operations, i.e., orbit response recognition and rotor re-levitation. In the operation of orbit response recognition, the three orbit responses (pendulum vibration, combined rub and bouncing, and full rub) can be identified by the expectation of radial displacement of rotor and expectation of instantaneous frequency (IF) of rotor motion in the sampling period. In the rotor re-levitation operation, a decentralized PID control algorithm is employed for pendulum vibration and combined rub and bouncing, and the decentralized PID control algorithm and another whirl damping algorithm, in which the weighting factor is determined by the whirl frequency, are jointly executed for the full rub. The method has been demonstrated by the simulation results of an AMB model. The results reveal that the method is effective in actively suppressing the whirl motion and promptly re-levitating the rotor. As the PID control algorithm and the simple operations of signal processing are employed, the algorithm has a low computation intensity, which makes it more easily realized in practical applications.
Paul-Murphy, Joanne R; Sladky, Kurt K; Krugner-Higby, Lisa A; Stading, Ben R; Klauer, Julia M; Keuler, Nicholas S; Brown, Carolyn S; Heath, Timothy D
2009-10-01
To evaluate the microcrystalline sodium urate (MSU) method for inducing arthritis in parrots and to compare the analgesic efficacy of long-acting liposome-encapsulated butorphanol (LEBT), carprofen, or a combination of both. 20 Hispaniolan parrots. MSU was injected into a tibiotarsal-tarsometatarsal (intertarsal) joint to induce arthritis (time 0). Four treatments were compared (LEBT [15 mg/kg, SC] administered once at time 0; injections of carprofen [3 mg/kg, IM, q 12 h] starting at time 0; administration of LEBT plus carprofen; and a control treatment of saline [0.9% NaCl] solution). Weight load testing and behavioral scoring were conducted at 0, 2, 6, 26, and 30 hours. Injection of MSU into the intertarsal joint induced arthritis, which resolved within 30 hours. Treatment with LEBT or LEBT plus carprofen resulted in significantly greater weight-bearing load on the limb with induced arthritis, compared with the control treatment. Treatment with carprofen alone caused a slight but nonsignificant improvement in weight-bearing load on the arthritic limb, compared with the control treatment. Behaviors associated with motor activity and weight bearing differed between the control and analgesic treatments. Butorphanol was an effective treatment for pain associated with arthritis, but carprofen administered every 12 hours was insufficient. Injection of MSU to induce arthritis in a single joint was a good method for evaluating tonic pain in parrots, and measurement of the weight-bearing load was accurate for assessment of arthritic pain; however, behavioral changes associated with pain were subtle.
Predicting functional recovery after acute ankle sprain.
O'Connor, Sean R; Bleakley, Chris M; Tully, Mark A; McDonough, Suzanne M
2013-01-01
Ankle sprains are among the most common acute musculoskeletal conditions presenting to primary care. Their clinical course is variable but there are limited recommendations on prognostic factors. Our primary aim was to identify clinical predictors of short and medium term functional recovery after ankle sprain. A secondary analysis of data from adult participants (N = 85) with an acute ankle sprain, enrolled in a randomized controlled trial was undertaken. The predictive value of variables (age, BMI, gender, injury mechanism, previous injury, weight-bearing status, medial joint line pain, pain during weight-bearing dorsiflexion and lateral hop test) recorded at baseline and at 4 weeks post injury were investigated for their prognostic ability. Recovery was determined from measures of subjective ankle function at short (4 weeks) and medium term (4 months) follow ups. Multivariate stepwise linear regression analyses were undertaken to evaluate the association between the aforementioned variables and functional recovery. Greater age, greater injury grade and weight-bearing status at baseline were associated with lower function at 4 weeks post injury (p<0.01; adjusted R square=0.34). Greater age, weight-bearing status at baseline and non-inversion injury mechanisms were associated with lower function at 4 months (p<0.01; adjusted R square=0.20). Pain on medial palpation and pain on dorsiflexion at 4 weeks were the most valuable prognostic indicators of function at 4 months (p< 0.01; adjusted R square=0.49). The results of the present study provide further evidence that ankle sprains have a variable clinical course. Age, injury grade, mechanism and weight-bearing status at baseline provide some prognostic information for short and medium term recovery. Clinical assessment variables at 4 weeks were the strongest predictors of recovery, explaining 50% of the variance in ankle function at 4 months. Further prospective research is required to highlight the factors that best inform the expected convalescent period, and risk of recurrence.
Chimenti, Ruth L; Flemister, A Samuel; Tome, Joshua; McMahon, James M; Houck, Jeff R
2016-12-01
Study Design Controlled laboratory study; cross-sectional. Background Little is known about ankle range of motion (ROM) and strength among patients with insertional Achilles tendinopathy (IAT) and whether limited ankle ROM and plantar flexor weakness impact IAT symptom severity. Objectives The purposes of the study were (1) to examine whether participants with IAT exhibit limited non-weight-bearing dorsiflexion ROM, reduced plantar flexor strength, and/or altered ankle biomechanics during stair ascent; and (2) to determine which impairments are associated with symptom severity. Methods Participants included 20 patients with unilateral IAT (mean ± SD age, 59 ± 8 years; 55% female) and 20 individuals without tendinopathy (age, 58.2 ± 8.5 years; 55% female). A dynamometer was used to measure non-weight-bearing ROM and isometric plantar flexor strength. Three-dimensional motion analysis was used to quantify ankle biomechanics during stair ascent. End-range dorsiflexion was quantified as the percentage of non-weight-bearing dorsiflexion used during stair ascent. Group differences were compared using 2-way and 1-way analyses of variance. Pearson correlations were used to test for associations among dependent variables and symptom severity. Results Groups differed in ankle biomechanics, but not non-weight-bearing ROM or strength. During stair ascent, the IAT group used greater end-range dorsiflexion (P = .03), less plantar flexion (P = .02), and lower peak ankle plantar flexor power (P = .01) than the control group. Higher end-range dorsiflexion and lower ankle power during stair ascent were associated with greater symptom severity (P<.05). Conclusion Patients with IAT do not experience restrictions in non-weight-bearing dorsiflexion ROM or isometric plantar flexor strength. However, altered ankle biomechanics during stair ascent were linked with greater symptom severity and likely contribute to decreased function. J Orthop Sports Phys Ther 2016;46(12):1051-1060. Epub 29 Oct 2016. doi:10.2519/jospt.2016.6462.
van Lieshout, Remko; Pisters, Martijn F; Vanwanseele, Benedicte; de Bie, Rob A; Wouters, Eveline J; Stukstette, Mirelle J
2016-01-01
Partial weight bearing is frequently instructed by physical therapists in patients after lower-limb trauma or surgery. The use of biofeedback devices seems promising to improve the patient's compliance with weight-bearing instructions. SmartStep and OpenGo-Science are biofeedback devices that provide real-time feedback. For a successful implementation, usability of the devices is a critical aspect and should be tested from a user's perspective. To describe the usability from the physical therapists' and a patients' perspective of Smartstep and OpenGo-Science to provide feedback on partial weight bearing during supervised rehabilitation of patients after lower-limb trauma or surgery. In a convergent mixed-methods design, qualitative and quantitative data were collected. Usability was subdivided into user performance, satisfaction and acceptability. Patients prescribed with partial weight bearing and their physical therapists were asked to use SmartStep and OpenGo-Science during supervised rehabilitation. Usability was qualitatively tested by a think-aloud method and a semi-structured interview and quantitatively tested by the System-Usability-Scale (SUS) and closed questions. For the qualitative data thematic content analyses were used. Nine pairs of physical therapists and their patients participated. The mean SUS scores for patients and physical therapists were for SmartStep 70 and 53, and for OpenGo-Science 79 and 81, respectively. Scores were interpreted with the Curved Grading Scale. The qualitative data showed that there were mixed views and perceptions from patients and physical therapists on satisfaction and acceptability. This study gives insight in the usability of two biofeedback devices from the patient's and physical therapist's perspective. The overall usability from both perspectives seemed to be acceptable for OpenGo-Science. For SmartStep, overall usability seemed only acceptable from the patient's perspective. The study findings could help clinicians to decide which biofeedback device is appropriate for their given situation and provide information for future development of biofeedback devices.
Pediatric Diaphyseal Femur Fractures: Submuscular Plating Compared With Intramedullary Nailing.
Sutphen, Sean A; Mendoza, Juan D; Mundy, Andrew C; Yang, Jingzhen G; Beebe, Allan C; Samora, Walter P; Klingele, Kevin E
2016-11-01
This study compared the radiographic and clinical outcomes of pediatric diaphyseal femur fractures treated by submuscular plating, flexible retrograde intramedullary nailing, or rigid antegrade intramedullary nailing with a trochanteric entry point in skeletally immature patients who were 8 years and older. A retrospective review was conducted of skeletally immature patients 8 years and older who were treated for femur fracture with submuscular plating, flexible intramedullary nailing, or rigid intramedullary nailing from 2001 to 2014 with a minimum 12-week follow-up. Treatment outcomes were compared for statistical significance, including time to union, malunion, nonunion, heterotopic ossification, avascular necrosis, time to full weight bearing, limb length discrepancy, residual limp, painful hardware, and infection. The study identified 198 femur fractures in 196 patients (mean age, 11.9 years). Each femur fracture was treated with submuscular plating (35), flexible intramedullary nailing (61), or rigid intramedullary nailing (102). Mean follow-up across the cohort was 48 weeks, ranging from 12 to 225 weeks. Flexible nailing was associated with an increased incidence of malunion (P<.0001) and hardware irritation (P=.0204) and longer time to full weight bearing (P=.0018). Rigid nailing was associated with an increased incidence of limp at 12-week followup (P=.0412). Additionally, 23.5% of patients who were treated with rigid nailing had heterotopic ossification. Of all surgical methods, submuscular plating allowed for the most rapid return to full weight bearing (mean, 7 weeks) and offered the fastest healing rate (mean, 6 weeks). Submuscular plating resulted in faster times to union and full weight bearing, with minimal complication rates. Rigid intramedullary nailing with trochanteric entry resulted in a lower incidence of malunion and hardware-related complications; however, these patients had an increased incidence of heterotopic ossification and residual limp postoperatively. Flexible retrograde intramedullary nailing resulted in the highest rates of malunion and hardware irritation and the longest time to full weight bearing. [Orthopedics. 2016; 39(6):353-358.]. Copyright 2016, SLACK Incorporated.
Vico, Laurence; van Rietbergen, Bert; Vilayphiou, Nicolas; Linossier, Marie-Thérèse; Locrelle, Hervé; Normand, Myriam; Zouch, Mohamed; Gerbaix, Maude; Bonnet, Nicolas; Novikov, Valery; Thomas, Thierry; Vassilieva, Galina
2017-10-01
Risk for premature osteoporosis is a major health concern in astronauts and cosmonauts; the reversibility of the bone lost at the weight-bearing bone sites is not established, although it is suspected to take longer than the mission length. The bone three-dimensional structure and strength that could be uniquely affected by weightlessness is currently unknown. Our objective is to evaluate bone mass, microarchitecture, and strength of weight-bearing and non-weight-bearing bone in 13 cosmonauts before and for 12 months after a 4-month to 6-month sojourn in the International Space Station (ISS). Standard and advanced evaluations of trabecular and cortical parameters were performed using high-resolution peripheral quantitative computed tomography. In particular, cortical analyses involved determination of the largest common volume of each successive individual scan to improve the precision of cortical porosity and density measurements. Bone resorption and formation serum markers, and markers reflecting osteocyte activity or periosteal metabolism (sclerostin, periostin) were evaluated. At the tibia, in addition to decreased bone mineral densities at cortical and trabecular compartments, a 4% decrease in cortical thickness and a 15% increase in cortical porosity were observed at landing. Cortical size and density subsequently recovered and serum periostin changes were associated with cortical recovery during the year after landing. However, tibial cortical porosity or trabecular bone failed to recover, resulting in compromised strength. The radius, preserved at landing, unexpectedly developed postflight fragility, from 3 months post-landing onward, particularly in its cortical structure. Remodeling markers, uncoupled in favor of bone resorption at landing, returned to preflight values within 6 months, then declined farther to lower than preflight values. Our findings highlight the need for specific protective measures not only during, but also after spaceflight, because of continuing uncertainties regarding skeletal recovery long after landing. © 2017 American Society for Bone and Mineral Research. © 2017 American Society for Bone and Mineral Research.
Code of Federal Regulations, 2013 CFR
2013-01-01
... abbreviation or simulation of any official mark, to or on any product, or container thereof, except under the... product, any container bearing or intended to bear any official mark, or any abbreviation or simulation of...
Code of Federal Regulations, 2011 CFR
2011-01-01
... abbreviation or simulation of any official mark, to or on any product, or container thereof, except under the... product, any container bearing or intended to bear any official mark, or any abbreviation or simulation of...
Code of Federal Regulations, 2012 CFR
2012-01-01
... abbreviation or simulation of any official mark, to or on any product, or container thereof, except under the... product, any container bearing or intended to bear any official mark, or any abbreviation or simulation of...
Code of Federal Regulations, 2010 CFR
2010-01-01
... abbreviation or simulation of any official mark, to or on any product, or container thereof, except under the... product, any container bearing or intended to bear any official mark, or any abbreviation or simulation of...
Code of Federal Regulations, 2014 CFR
2014-01-01
... abbreviation or simulation of any official mark, to or on any product, or container thereof, except under the... product, any container bearing or intended to bear any official mark, or any abbreviation or simulation of...
Cao, Hongrui; Niu, Linkai; He, Zhengjia
2012-01-01
Bearing defects are one of the most important mechanical sources for vibration and noise generation in machine tool spindles. In this study, an integrated finite element (FE) model is proposed to predict the vibration responses of a spindle bearing system with localized bearing defects and then the sensor placement for better detection of bearing faults is optimized. A nonlinear bearing model is developed based on Jones' bearing theory, while the drawbar, shaft and housing are modeled as Timoshenko's beam. The bearing model is then integrated into the FE model of drawbar/shaft/housing by assembling equations of motion. The Newmark time integration method is used to solve the vibration responses numerically. The FE model of the spindle-bearing system was verified by conducting dynamic tests. Then, the localized bearing defects were modeled and vibration responses generated by the outer ring defect were simulated as an illustration. The optimization scheme of the sensor placement was carried out on the test spindle. The results proved that, the optimal sensor placement depends on the vibration modes under different boundary conditions and the transfer path between the excitation and the response. PMID:23012514
Picture object recognition in an American black bear (Ursus americanus).
Johnson-Ulrich, Zoe; Vonk, Jennifer; Humbyrd, Mary; Crowley, Marilyn; Wojtkowski, Ela; Yates, Florence; Allard, Stephanie
2016-11-01
Many animals have been tested for conceptual discriminations using two-dimensional images as stimuli, and many of these species appear to transfer knowledge from 2D images to analogous real life objects. We tested an American black bear for picture-object recognition using a two alternative forced choice task. She was presented with four unique sets of objects and corresponding pictures. The bear showed generalization from both objects to pictures and pictures to objects; however, her transfer was superior when transferring from real objects to pictures, suggesting that bears can recognize visual features from real objects within photographic images during discriminations.
An electric motor with magnetic bearings: A concept
NASA Technical Reports Server (NTRS)
Studer, P. A.
1973-01-01
Because same magnetic flux is used to control rotor as to drive it, size, weight, and power required are minimized. Constant total current keeps motor torque invarient, and absence of mechanical bearings eliminates wear and reduces frictional power loss.
NASA Astrophysics Data System (ADS)
Ousaloo, H. S.; Nodeh, M. T.; Mehrabian, R.
2016-09-01
This paper accomplishes one goal and it was to verify and to validate a Spin Magnetic Attitude Control System (SMACS) program and to perform Hardware-In-the-Loop (HIL) air-bearing experiments. A study of a closed-loop magnetic spin controller is presented using only magnetic rods as actuators. The magnetic spin rate control approach is able to perform spin rate control and it is verified with an Attitude Control System (ACS) air-bearing MATLAB® SIMULINK® model and a hardware-embedded LABVIEW® algorithm that controls the spin rate of the test platform on a spherical air bearing table. The SIMULINK® model includes dynamic model of air-bearing, its disturbances, actuator emulation and the time delays caused by on-board calculations. The air-bearing simulator is employed to develop, improve, and carry out objective tests of magnetic torque rods and spin rate control algorithm in the experimental framework and to provide a more realistic demonstration of expected performance of attitude control as compared with software-based architectures. Six sets of two torque rods are used as actuators for the SMACS. It is implemented and simulated to fulfill mission requirement including spin the satellite up to 12 degs-1 around the z-axis. These techniques are documented for the full nonlinear equations of motion of the system and the performances of these techniques are compared in several simulations.
New technique for simulation of microgravity and variable gravity conditions
NASA Astrophysics Data System (ADS)
de la Rosa, R.; Alonso, A.; Abasolo, D. E.; Hornero, R.; Abasolo, D. E.
2005-08-01
This paper suggests a microgravity or variable gravity conditions simulator based on a Neuromuscular Control System (NCS), working as a man-machine interface. The subject under training lies on an active platform that counteracts his weight. And a Virtual Reality (VR) system displays a simulated environment, where the subject can interact a number of settings: extravehicular activity (EVA), walking on the Moon or training the limb response faced with variable acceleration scenes. Results related to real-time voluntary control have been achieved with neuromuscular interfaces at the Bioengineering Group in the University of Valladolid. It has been employed a custom real-time system to train arm movements. This paper outlines a more complex design that can complement other training facilities, like the buoyancy pool, in the task of microgravity simulation.
Influence of structural parameters of deep groove ball bearings on vibration
NASA Astrophysics Data System (ADS)
Yu, Guangwei; Wu, Rui; Xia, Wei
2018-04-01
Taking 6201 bearing as the research object, a dynamic model of 4 degrees of freedom is established to solve the vibration characteristics such as the displacement, velocity and acceleration of deep groove ball bearings by MATLAB and Runge-Kutta method. By calculating the theoretical value of the frequency of the rolling element passing through the outer ring and the simulation value of the model, it can be known that the theoretical calculation value and the simulation value have good consistency. By the experiments, the measured values and simulation values are consistent. Using the mathematical model, the effect of structural parameters on vibration is obtained. The method in the paper is testified to be feasible and the results can be used as references for the design, manufacturing and testing of deep groove ball bearings.
Compelled Body Weight Shift Technique to Facilitate Rehabilitation of Individuals with Acute Stroke
Mohapatra, Sambit; Eviota, Aileen C.; Ringquist, Keir L.; Muthukrishnan, Sri Ranjini; Aruin, Alexander S.
2014-01-01
Background The study evaluates the effectiveness of Compelled Body Weight Shift (CBWS) approach in the rehabilitation of individuals with stroke. CBWS involves a forced shift of body weight towards a person’s affected side by means of a shoe insert that establishes a lift of the nonaffected lower extremity. Methods Eleven patients with acute stroke were randomly assigned to experimental and control groups. The experimental group received a two-week conventional physical therapy combined with CBWS and the control group received only a two-week conventional therapy. Weight bearing, Gait velocity, Berg’s Balance, and Fugl-Meyer’s Scores were recorded before and after the intervention. Results Weight bearing on the affected side increased in the experimental group and decreased in the control group. The increase in gait velocity with treatment was significant in both the groups (P < 0.05). However, experimental group (P = 0.01) demonstrated larger improvements in gait velocity compared to the control group (P = 0.002). Berg Balance and Fugl-Meyer scores increased for both the groups. Conclusion The implementation of a two-week intervention with CBWS resulted in the improvement in weight bearing and gait velocity of individuals with acute stroke. The present preliminary study suggests that CBWS technique could be implemented as an adjunct to conventional rehabilitation program for individuals with acute stroke. PMID:25530888
Augmenting forearm crutches with wireless sensors for lower limb rehabilitation
NASA Astrophysics Data System (ADS)
Merrett, Geoff V.; Ettabib, Mohamed A.; Peters, Christian; Hallett, Georgina; White, Neil M.
2010-12-01
Forearm crutches are frequently used in the rehabilitation of an injury to the lower limb. The recovery rate is improved if the patient correctly applies a certain fraction of their body weight (specified by a clinician) through the axis of the crutch, referred to as partial weight bearing (PWB). Incorrect weight bearing has been shown to result in an extended recovery period or even cause further damage to the limb. There is currently no minimally invasive tool for long-term monitoring of a patient's PWB in a home environment. This paper describes the research and development of an instrumented forearm crutch that has been developed to wirelessly and autonomously monitor a patient's weight bearing over the full period of their recovery, including its potential use in a home environment. A pair of standard forearm crutches are augmented with low-cost off-the-shelf wireless sensor nodes and electronic components to provide indicative measurements of the applied weight, crutch tilt and hand position on the grip. Data are wirelessly transmitted between crutches and to a remote computer (where they are processed and visualized in LabVIEW), and the patient receives biofeedback by means of an audible signal when they put too much or too little weight through the crutch. The initial results obtained highlight the capability of the instrumented crutch to support physiotherapists and patients in monitoring usage.
Hosny, Iman Abbas; Elghawabi, Hamed Samir; Younan, Wael Bahat Fahmy; Sabbour, Adly Aly; Gobrial, Mona Abdel Messih
2012-04-01
The aim of this study was to assess the impact of caloric restriction diet versus caloric restriction diet combined with aerobic exercises on bone mineral density (BMD) in obese premenopausal women. Forty premenopausal obese women were classified randomly into two groups equal in number. The first group (group A) received caloric restriction diet, while the second (group B) received caloric restriction diet combined with a program of aerobic exercises, over 3 months. The variables measured in this study included age, weight, height, body mass index, fat weight, lean mass, fat percent, basal metabolic rate, and BMD. The comparison between group A and group B showed significantly higher post-treatment lean mass, basal metabolic rate, and BMD in weight-bearing bones (L2-L4 lumbar spine and total hip) in group B compared to group A. In contrast to the BMD of the weight-bearing bones, the BMD of the radius showed significant decrease between the pre- and post-treatment results in groups A and B with no significant differences between the two groups. A greater improvement in the BMD of weight-bearing bones was observed in obese premenopausal women undergoing caloric restriction combined with exercise than in those not undergoing exercise. Anaerobic exercises incorporated into weight loss programs help offset the adverse effects of dietary restriction on bone.
Li, Xuejun; Xu, Jia; Yang, Yun
2015-01-01
Cloud workflow system is a kind of platform service based on cloud computing. It facilitates the automation of workflow applications. Between cloud workflow system and its counterparts, market-oriented business model is one of the most prominent factors. The optimization of task-level scheduling in cloud workflow system is a hot topic. As the scheduling is a NP problem, Ant Colony Optimization (ACO) and Particle Swarm Optimization (PSO) have been proposed to optimize the cost. However, they have the characteristic of premature convergence in optimization process and therefore cannot effectively reduce the cost. To solve these problems, Chaotic Particle Swarm Optimization (CPSO) algorithm with chaotic sequence and adaptive inertia weight factor is applied to present the task-level scheduling. Chaotic sequence with high randomness improves the diversity of solutions, and its regularity assures a good global convergence. Adaptive inertia weight factor depends on the estimate value of cost. It makes the scheduling avoid premature convergence by properly balancing between global and local exploration. The experimental simulation shows that the cost obtained by our scheduling is always lower than the other two representative counterparts.
Li, Xuejun; Xu, Jia; Yang, Yun
2015-01-01
Cloud workflow system is a kind of platform service based on cloud computing. It facilitates the automation of workflow applications. Between cloud workflow system and its counterparts, market-oriented business model is one of the most prominent factors. The optimization of task-level scheduling in cloud workflow system is a hot topic. As the scheduling is a NP problem, Ant Colony Optimization (ACO) and Particle Swarm Optimization (PSO) have been proposed to optimize the cost. However, they have the characteristic of premature convergence in optimization process and therefore cannot effectively reduce the cost. To solve these problems, Chaotic Particle Swarm Optimization (CPSO) algorithm with chaotic sequence and adaptive inertia weight factor is applied to present the task-level scheduling. Chaotic sequence with high randomness improves the diversity of solutions, and its regularity assures a good global convergence. Adaptive inertia weight factor depends on the estimate value of cost. It makes the scheduling avoid premature convergence by properly balancing between global and local exploration. The experimental simulation shows that the cost obtained by our scheduling is always lower than the other two representative counterparts. PMID:26357510
Preschool physics: Using the invisible property of weight in causal reasoning tasks
Williamson, Rebecca A.; Meltzoff, Andrew N.
2018-01-01
Causal reasoning is an important aspect of scientific thinking. Even young human children can use causal reasoning to explain observations, make predictions, and design actions to bring about specific outcomes in the physical world. Weight is an interesting type of cause because it is an invisible property. Here, we tested preschool children with causal problem-solving tasks that assessed their understanding of weight. In an experimental setting, 2- to 5-year-old children completed three different tasks in which they had to use weight to produce physical effects—an object displacement task, a balance-scale task, and a tower-building task. The results showed that the children’s understanding of how to use object weight to produce specific object-to-object causal outcomes improved as a function of age, with 4- and 5-year-olds showing above-chance performance on all three tasks. The younger children’s performance was more variable. The pattern of results provides theoretical insights into which aspects of weight processing are particularly difficult for preschool children and why they find it difficult. PMID:29561840
Preschool physics: Using the invisible property of weight in causal reasoning tasks.
Wang, Zhidan; Williamson, Rebecca A; Meltzoff, Andrew N
2018-01-01
Causal reasoning is an important aspect of scientific thinking. Even young human children can use causal reasoning to explain observations, make predictions, and design actions to bring about specific outcomes in the physical world. Weight is an interesting type of cause because it is an invisible property. Here, we tested preschool children with causal problem-solving tasks that assessed their understanding of weight. In an experimental setting, 2- to 5-year-old children completed three different tasks in which they had to use weight to produce physical effects-an object displacement task, a balance-scale task, and a tower-building task. The results showed that the children's understanding of how to use object weight to produce specific object-to-object causal outcomes improved as a function of age, with 4- and 5-year-olds showing above-chance performance on all three tasks. The younger children's performance was more variable. The pattern of results provides theoretical insights into which aspects of weight processing are particularly difficult for preschool children and why they find it difficult.
Filtration effects on ball bearing life and condition in a contaminated lubricant
NASA Technical Reports Server (NTRS)
Loewenthal, S. H.; Moyer, D. W.
1978-01-01
Ball bearings were fatigue tested with a noncontaminated MIL-L-23699 lubricant and with a contaminated MIL-L-23699 lubricant under four levels of filtration. The test filters had absolute particle removal ratings of 3, 30, 49, and 105 microns. Aircraft turbine engine contaminants were injected into the filter's supply line at a constant rate of 125 milligrams per bearing hour. Bearing life and running track condition generally improved with finer filtration. The experimental lives of 3- and 30-micron filter bearings were statistically equivalent, approaching those obtained with the noncontaminated lubricant bearings. Compared to these bearings, the lives of the 49-micron bearings were statistically lower. The 105-micron bearings experienced gross wear. The degree of surface distress, weight loss, and probable failure mode were dependent on filtration level, with finer filtration being clearly beneficial.
Robust gene selection methods using weighting schemes for microarray data analysis.
Kang, Suyeon; Song, Jongwoo
2017-09-02
A common task in microarray data analysis is to identify informative genes that are differentially expressed between two different states. Owing to the high-dimensional nature of microarray data, identification of significant genes has been essential in analyzing the data. However, the performances of many gene selection techniques are highly dependent on the experimental conditions, such as the presence of measurement error or a limited number of sample replicates. We have proposed new filter-based gene selection techniques, by applying a simple modification to significance analysis of microarrays (SAM). To prove the effectiveness of the proposed method, we considered a series of synthetic datasets with different noise levels and sample sizes along with two real datasets. The following findings were made. First, our proposed methods outperform conventional methods for all simulation set-ups. In particular, our methods are much better when the given data are noisy and sample size is small. They showed relatively robust performance regardless of noise level and sample size, whereas the performance of SAM became significantly worse as the noise level became high or sample size decreased. When sufficient sample replicates were available, SAM and our methods showed similar performance. Finally, our proposed methods are competitive with traditional methods in classification tasks for microarrays. The results of simulation study and real data analysis have demonstrated that our proposed methods are effective for detecting significant genes and classification tasks, especially when the given data are noisy or have few sample replicates. By employing weighting schemes, we can obtain robust and reliable results for microarray data analysis.
Mills, Brennen W; Miles, Alecka K; Phan, Tina; Dykstra, Peggy M C; Hansen, Sara S; Walsh, Andrew S; Reid, David N; Langdon, Claire
2018-04-18
Many healthcare education commentators suggest that moulage can be used in simulation to enhance scenario realism. However, few studies investigate to what extent using moulage in simulation impacts learners. We undertook a mixed-methods pilot study investigating how moulage influences student immersion and performance in simulation. Fifty undergraduate paramedicine students were randomized into two groups completing a trauma-based scenario with or without patient moulage. Task immersion was determined via a self-report questionnaire (National Aeronautics and Space Administration Task Load Index), eye-tracking, and postsimulation interviews. Performance was measured via independent observation of video by two paramedic clinical educators and time-to-action-when students first applied pressure to the primary wound. Eye-tracking suggested that students attended to the thigh wound more often with the inclusion of moulage than without. National Aeronautics and Space Administration Task Load Index data suggested that the inclusion of moulage heightened students' feeling of being rushed throughout the scenario. This elicited an expedited performance of tasks with moulage present compared with not. Students experienced greater immersion with the inclusion of moulage. However, including moulage enhanced scenario difficulty to the extent that overall clinical performance was negatively affected. However, no differences were found when more heavily weighting items felt to contribute most to the survivability of the patient. Including moulage engendered immersion and a greater sense of urgency and did not sacrifice performance of key life-saving interventions. As a result of undertaking this pilot project, we suggest that a large-scale randomized controlled trial is feasible and should be undertaken before implementing change to curricula.
Superconducting Meissner Effect Bearings for Cryogenic Turbomachines
1991-02-27
mnft turboexpanders used in spaceborne cryocoolers for surveillance sensors. A bearingi breadboard was designed, fabricated, and tested to a... Turboexpander ................................ 8 4.4 Task 7 - Report and Manage ................................... 10 5 SUMMARY AND CONCLUSIONS...fabrication techniques. These studies were performed for a I watt, 10 K cryocooler, where gas bearings for the coldest turboexpander were replaced with
Shen, Changqing; Liu, Fang; Wang, Dong; Zhang, Ao; Kong, Fanrang; Tse, Peter W.
2013-01-01
The condition of locomotive bearings, which are essential components in trains, is crucial to train safety. The Doppler effect significantly distorts acoustic signals during high movement speeds, substantially increasing the difficulty of monitoring locomotive bearings online. In this study, a new Doppler transient model based on the acoustic theory and the Laplace wavelet is presented for the identification of fault-related impact intervals embedded in acoustic signals. An envelope spectrum correlation assessment is conducted between the transient model and the real fault signal in the frequency domain to optimize the model parameters. The proposed method can identify the parameters used for simulated transients (periods in simulated transients) from acoustic signals. Thus, localized bearing faults can be detected successfully based on identified parameters, particularly period intervals. The performance of the proposed method is tested on a simulated signal suffering from the Doppler effect. Besides, the proposed method is used to analyze real acoustic signals of locomotive bearings with inner race and outer race faults, respectively. The results confirm that the periods between the transients, which represent locomotive bearing fault characteristics, can be detected successfully. PMID:24253191
Shen, Changqing; Liu, Fang; Wang, Dong; Zhang, Ao; Kong, Fanrang; Tse, Peter W
2013-11-18
The condition of locomotive bearings, which are essential components in trains, is crucial to train safety. The Doppler effect significantly distorts acoustic signals during high movement speeds, substantially increasing the difficulty of monitoring locomotive bearings online. In this study, a new Doppler transient model based on the acoustic theory and the Laplace wavelet is presented for the identification of fault-related impact intervals embedded in acoustic signals. An envelope spectrum correlation assessment is conducted between the transient model and the real fault signal in the frequency domain to optimize the model parameters. The proposed method can identify the parameters used for simulated transients (periods in simulated transients) from acoustic signals. Thus, localized bearing faults can be detected successfully based on identified parameters, particularly period intervals. The performance of the proposed method is tested on a simulated signal suffering from the Doppler effect. Besides, the proposed method is used to analyze real acoustic signals of locomotive bearings with inner race and outer race faults, respectively. The results confirm that the periods between the transients, which represent locomotive bearing fault characteristics, can be detected successfully.
Multiphysics Object Oriented Simulation Environment
DOE Office of Scientific and Technical Information (OSTI.GOV)
The Multiphysics Object Oriented Simulation Environment (MOOSE) software library developed at Idaho National Laboratory is a tool. MOOSE, like other tools, doesn't actually complete a task. Instead, MOOSE seeks to reduce the effort required to create engineering simulation applications. MOOSE itself is a software library: a blank canvas upon which you write equations and then MOOSE can help you solve them. MOOSE is comparable to a spreadsheet application. A spreadsheet, by itself, doesn't do anything. Only once equations are entered into it will a spreadsheet application compute anything. Such is the same for MOOSE. An engineer or scientist can utilizemore » the equation solvers within MOOSE to solve equations related to their area of study. For instance, a geomechanical scientist can input equations related to water flow in underground reservoirs and MOOSE can solve those equations to give the scientist an idea of how water could move over time. An engineer might input equations related to the forces in steel beams in order to understand the load bearing capacity of a bridge. Because MOOSE is a blank canvas it can be useful in many scientific and engineering pursuits.« less
Integration of an Earth-Based Science Team During Human Exploration of Mars
NASA Technical Reports Server (NTRS)
Chappell, Steven P.; Beaton, Kara H.; Newton, Carolyn; Graff, Trevor G.; Young, Kelsey E.; Coan, David; Abercromby, Andrew F. J.; Gernhardt, Michael L.
2017-01-01
NASA Extreme Environment Mission Operations (NEEMO) is an underwater spaceflight analog that allows a true mission-like operational environment and uses buoyancy effects and added weight to simulate different gravity levels. A mission was undertaken in 2016, NEEMO 21, at the Aquarius undersea research habitat. During the mission, the effects of varied oper-ations concepts with representative communication latencies as-sociated with Mars missions were studied. Six subjects were weighed out to simulate partial gravity and evaluated different operations concepts for integration and management of a simulated Earth-based science team (ST) who provided input and direction during exploration activities. Exploration traverses were planned in advance based on precursor data collected. Subjects completed science-related tasks including presampling surveys and marine-science-based sampling during saturation dives up to 4 hours in duration that simulated extravehicular activity (EVA) on Mars. A communication latency of 15 minutes in each direction between space and ground was simulated throughout the EVAs. Objective data included task completion times, total EVA time, crew idle time, translation time, ST assimilation time (defined as time available for the science team to discuss, to review and act upon data/imagery after they have been collected and transmitted to the ground). Subjective data included acceptability, simulation quality, capability assessment ratings, and comments. In addition, comments from both the crew and the ST were captured during the post-mission debrief. Here, we focus on the acceptability of the operations concepts studied and the capabilities most enhancing or enabling in the operations concept. The importance and challenges of designing EVA time-lines to account for the length of the task, level of interaction with the ground that is required/desired, and communication latency, are discussed.
Design and fabrication of a full-scale actively controlled satellite appendage simulator unit
NASA Astrophysics Data System (ADS)
Jacobs, Jack H.; Quenon, Dan; Hadden, Steve; Self, Rick
1999-07-01
Modern satellites require the ability to slew and settle quickly in order to acquire or transmit data efficiently. Solar arrays and communication antennas cause low frequency disturbances to the satellite bus during these maneuvers causing undesirable induced vibration of the payload. The ability to develop and experimentally demonstrate attitude control laws which compensate for these flexible body disturbances is of prime importance to modern day satellite manufacturers. Honeywell has designed and fabricated an actively controlled Appendage Simulator Unit (ASU) which can physically induce the modal characteristics of satellite appendages on to a ground based satellite test bed installed on an air bearing. The ASU consists of two orthogonal fulcrum beams weighting over 800 pounds each utilizing two electrodynamic shakers to induce active torques onto the bus. The ASU is programmed with the state space characteristics of the desired appendage and responds in real time to the bus motion to generate realistic disturbances back onto the satellite. Two LVDT's are used on each fulcrum beam to close the loop and insure the system responds in real time the same way a real solar array would on-orbit. Each axis is independently programmable in order to simulate various orientations or modal contributions from an appendage. The design process for the ASU involved the optimization of sensors, actuators, control authority, weight, power and functionality. The smart structure system design process and experimental results are described in detail.
Milella, Ferdinando; Pinto, Carlo; Cant, Iain; White, Mark; Meyer, Georg
2018-01-01
Objective and subjective measures of performance in virtual reality environments increase as more sensory cues are delivered and as simulation fidelity increases. Some cues (colour or sound) are easier to present than others (object weight, vestibular cues) so that substitute cues can be used to enhance informational content in a simulation at the expense of simulation fidelity. This study evaluates how substituting cues in one modality by alternative cues in another modality affects subjective and objective performance measures in a highly immersive virtual reality environment. Participants performed a wheel change in a virtual reality (VR) environment. Auditory, haptic and visual cues, signalling critical events in the simulation, were manipulated in a factorial design. Subjective ratings were recorded via questionnaires. The time taken to complete the task was used as an objective performance measure. The results show that participants performed best and felt an increased sense of immersion and involvement, collectively referred to as ‘presence’, when substitute multimodal sensory feedback was provided. Significant main effects of audio and tactile cues on task performance and on participants' subjective ratings were found. A significant negative relationship was found between the objective (overall completion times) and subjective (ratings of presence) performance measures. We conclude that increasing informational content, even if it disrupts fidelity, enhances performance and user’s overall experience. On this basis we advocate the use of substitute cues in VR environments as an efficient method to enhance performance and user experience. PMID:29390023
Cooper, Natalia; Milella, Ferdinando; Pinto, Carlo; Cant, Iain; White, Mark; Meyer, Georg
2018-01-01
Objective and subjective measures of performance in virtual reality environments increase as more sensory cues are delivered and as simulation fidelity increases. Some cues (colour or sound) are easier to present than others (object weight, vestibular cues) so that substitute cues can be used to enhance informational content in a simulation at the expense of simulation fidelity. This study evaluates how substituting cues in one modality by alternative cues in another modality affects subjective and objective performance measures in a highly immersive virtual reality environment. Participants performed a wheel change in a virtual reality (VR) environment. Auditory, haptic and visual cues, signalling critical events in the simulation, were manipulated in a factorial design. Subjective ratings were recorded via questionnaires. The time taken to complete the task was used as an objective performance measure. The results show that participants performed best and felt an increased sense of immersion and involvement, collectively referred to as 'presence', when substitute multimodal sensory feedback was provided. Significant main effects of audio and tactile cues on task performance and on participants' subjective ratings were found. A significant negative relationship was found between the objective (overall completion times) and subjective (ratings of presence) performance measures. We conclude that increasing informational content, even if it disrupts fidelity, enhances performance and user's overall experience. On this basis we advocate the use of substitute cues in VR environments as an efficient method to enhance performance and user experience.
Choi, Jang-Hwan; Maier, Andreas; Keil, Andreas; Pal, Saikat; McWalter, Emily J; Beaupré, Gary S; Gold, Garry E; Fahrig, Rebecca
2014-06-01
A C-arm CT system has been shown to be capable of scanning a single cadaver leg under loaded conditions by virtue of its highly flexible acquisition trajectories. In Part I of this study, using the 4D XCAT-based numerical simulation, the authors predicted that the involuntary motion in the lower body of subjects in weight-bearing positions would seriously degrade image quality and the authors suggested three motion compensation methods by which the reconstructions could be corrected to provide diagnostic image quality. Here, the authors demonstrate that a flat-panel angiography system is appropriate for scanning both legs of subjects in vivo under weight-bearing conditions and further evaluate the three motion-correction algorithms using in vivo data. The geometry of a C-arm CT system for a horizontal scan trajectory was calibrated using the PDS-2 phantom. The authors acquired images of two healthy volunteers while lying supine on a table, standing, and squatting at several knee flexion angles. In order to identify the involuntary motion of the lower body, nine 1-mm-diameter tantalum fiducial markers were attached around the knee. The static mean marker position in 3D, a reference for motion compensation, was estimated by back-projecting detected markers in multiple projections using calibrated projection matrices and identifying the intersection points in 3D of the back-projected rays. Motion was corrected using three different methods (described in detail previously): (1) 2D projection shifting, (2) 2D deformable projection warping, and (3) 3D rigid body warping. For quantitative image quality analysis, SSIM indices for the three methods were compared using the supine data as a ground truth. A 2D Euclidean distance-based metric of subjects' motion ranged from 0.85 mm (±0.49 mm) to 3.82 mm (±2.91 mm) (corresponding to 2.76 to 12.41 pixels) resulting in severe motion artifacts in 3D reconstructions. Shifting in 2D, 2D warping, and 3D warping improved the SSIM in the central slice by 20.22%, 16.83%, and 25.77% in the data with the largest motion among the five datasets (SCAN5); improvement in off-center slices was 18.94%, 29.14%, and 36.08%, respectively. The authors showed that C-arm CT control can be implemented for nonstandard horizontal trajectories which enabled us to scan and successfully reconstruct both legs of volunteers in weight-bearing positions. As predicted using theoretical models, the proposed motion correction methods improved image quality by reducing motion artifacts in reconstructions; 3D warping performed better than the 2D methods, especially in off-center slices.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Choi, Jang-Hwan; Maier, Andreas; Keil, Andreas
2014-06-15
Purpose: A C-arm CT system has been shown to be capable of scanning a single cadaver leg under loaded conditions by virtue of its highly flexible acquisition trajectories. In Part I of this study, using the 4D XCAT-based numerical simulation, the authors predicted that the involuntary motion in the lower body of subjects in weight-bearing positions would seriously degrade image quality and the authors suggested three motion compensation methods by which the reconstructions could be corrected to provide diagnostic image quality. Here, the authors demonstrate that a flat-panel angiography system is appropriate for scanning both legs of subjectsin vivo undermore » weight-bearing conditions and further evaluate the three motion-correction algorithms using in vivo data. Methods: The geometry of a C-arm CT system for a horizontal scan trajectory was calibrated using the PDS-2 phantom. The authors acquired images of two healthy volunteers while lying supine on a table, standing, and squatting at several knee flexion angles. In order to identify the involuntary motion of the lower body, nine 1-mm-diameter tantalum fiducial markers were attached around the knee. The static mean marker position in 3D, a reference for motion compensation, was estimated by back-projecting detected markers in multiple projections using calibrated projection matrices and identifying the intersection points in 3D of the back-projected rays. Motion was corrected using three different methods (described in detail previously): (1) 2D projection shifting, (2) 2D deformable projection warping, and (3) 3D rigid body warping. For quantitative image quality analysis, SSIM indices for the three methods were compared using the supine data as a ground truth. Results: A 2D Euclidean distance-based metric of subjects’ motion ranged from 0.85 mm (±0.49 mm) to 3.82 mm (±2.91 mm) (corresponding to 2.76 to 12.41 pixels) resulting in severe motion artifacts in 3D reconstructions. Shifting in 2D, 2D warping, and 3D warping improved the SSIM in the central slice by 20.22%, 16.83%, and 25.77% in the data with the largest motion among the five datasets (SCAN5); improvement in off-center slices was 18.94%, 29.14%, and 36.08%, respectively. Conclusions: The authors showed that C-arm CT control can be implemented for nonstandard horizontal trajectories which enabled us to scan and successfully reconstruct both legs of volunteers in weight-bearing positions. As predicted using theoretical models, the proposed motion correction methods improved image quality by reducing motion artifacts in reconstructions; 3D warping performed better than the 2D methods, especially in off-center slices.« less
Engine Power Turbine and Propulsion Pod Arrangement Study
NASA Technical Reports Server (NTRS)
Robuck, Mark; Zhang, Yiyi
2014-01-01
A study has been conducted for NASA Glenn Research Center under contract NNC10BA05B, Task NNC11TA80T to identify beneficial arrangements of the turboshaft engine, transmissions and related systems within the propulsion pod nacelle of NASA's Large Civil Tilt-Rotor 2nd iteration (LCTR2) vehicle. Propulsion pod layouts were used to investigate potential advantages, disadvantages, as well as constraints of various arrangements assuming front or aft shafted engines. Results from previous NASA LCTR2 propulsion system studies and tasks performed by Boeing under NASA contracts are used as the basis for this study. This configuration consists of two Fixed Geometry Variable Speed Power Turbine Engines and related drive and rotor systems (per nacelle) arranged in tilting nacelles near the wing tip. Entry-into-service (EIS) 2035 technology is assumed for both the engine and drive systems. The variable speed rotor system changes from 100 percent speed for hover to 54 percent speed for cruise by the means of a two speed gearbox concept developed under previous NASA contracts. Propulsion and drive system configurations that resulted in minimum vehicle gross weight were identified in previous work and used here. Results reported in this study illustrate that a forward shafted engine has a slight weight benefit over an aft shafted engine for the LCTR2 vehicle. Although the aft shafted engines provide a more controlled and centered CG (between hover and cruise), the length of the long rotor shaft and complicated engine exhaust arrangement outweighed the potential benefits. A Multi-Disciplinary Analysis and Optimization (MDAO) approach for transmission sizing was also explored for this study. This tool offers quick analysis of gear loads, bearing lives, efficiencies, etc., through use of commercially available RomaxDESIGNER software. The goal was to create quick methods to explore various concept models. The output results from RomaxDESIGNER have been successfully linked to Boeing spreadsheets that generate gear tooth geometry in Catia 3D environment. Another initial goal was to link information from RomaxDESIGNER (such as hp, rpm, gear ratio) to populate Boeing's parametric weight spreadsheet and create an automated method to estimate drive system weight. This was only partially achieved due to the variety of weight models, number of manual inputs, and qualitative assessments required. A simplified weight spreadsheet was used with data inputs from RomaxDESIGNER along with manual inputs to perform rough weight calculations.
NASA Astrophysics Data System (ADS)
Yu, Yunluo; Pu, Guang; Jiang, Kyle
2017-12-01
The paper presents a numerical simulation study on hydrostatic thrust air bearings to assess the load capacity, compressed air consumptions, and the dynamic response. Finite Difference Method (FDM) and Finite Volume Method (FVM) are combined to solve the non-linear Reynolds equation to find the pressure distribution of the air bearing gas film and the total loading capacity of the bearing. The influence of design parameters on air film gap characteristics, including the air film thickness, supplied pressure, depth of the groove and external load, are investigated based on the proposed FDM model. The simulation results show that the thrust air bearings with a groove have a higher load capacity and air consumption than without a groove, and the load capacity and air consumption both increase with the depth of the groove. Bearings without the groove are better damped than those with the grooves, and the stability of thrust bearing decreases when the groove depth increases. The stability of the thrust bearings is also affected by their loading.
Interaction Dynamics Between a Flexible Rotor and an Auxiliary Clearance Bearing
NASA Technical Reports Server (NTRS)
Lawen, James L., Jr.; Flowers, George T.
1996-01-01
This study investigates the application of synchronous interaction dynamics methodology to the design of auxiliary bearing systems. The technique is applied to a flexible rotor system and comparisons are made between the behavior predicted by this analysis method and the observed simulation response characteristics. Of particular interest is the influence of coupled shaft/bearing vibration modes on rotordynamical behavior. Experimental studies are also perFormed to validate the simulation results and provide insight into the expected behavior of such a system.
Complex double-mass dynamic model of rotor on thrust foil gas dynamic bearings
NASA Astrophysics Data System (ADS)
Sytin, A.; Babin, A.; Vasin, S.
2017-08-01
The present paper considers simulation of a rotor’s dynamics behaviour on thrust foil gas dynamic bearings based on simultaneous solution of gas dynamics differential equations, equations of theory of elasticity, motion equations and some additional equations. A double-mass dynamic system was considered during the rotor’s motion simulation which allows not only evaluation of rotor’s dynamic behaviour, but also to evaluate the influence of operational and load parameters on the dynamics of the rotor-bearing system.
NDARC NASA Design and Analysis of Rotorcraft - Input, Appendix 4
NASA Technical Reports Server (NTRS)
Johnson, Wayne
2016-01-01
The NDARC code performs design and analysis tasks. The design task involves sizing the rotorcraft to satisfy specified design conditions and missions. The analysis tasks can include off-design mission performance analysis, flight performance calculation for point operating conditions, and generation of subsystem or component performance maps. The principal tasks (sizing, mission analysis, flight performance analysis) are shown in the figure as boxes with heavy borders. Heavy arrows show control of subordinate tasks. The aircraft description consists of all the information, input and derived, that denes the aircraft. The aircraft consists of a set of components, including fuselage, rotors, wings, tails, and propulsion. This information can be the result of the sizing task; can come entirely from input, for a fixed model; or can come from the sizing task in a previous case or previous job. The aircraft description information is available to all tasks and all solutions. The sizing task determines the dimensions, power, and weight of a rotorcraft that can perform a specified set of design conditions and missions. The aircraft size is characterized by parameters such as design gross weight, weight empty, rotor radius, and engine power available. The relations between dimensions, power, and weight generally require an iterative solution. From the design flight conditions and missions, the task can determine the total engine power or the rotor radius (or both power and radius can be fixed), as well as the design gross weight, maximum takeoff weight, drive system torque limit, and fuel tank capacity. For each propulsion group, the engine power or the rotor radius can be sized. Missions are defined for the sizing task, and for the mission performance analysis. A mission consists of a number of mission segments, for which time, distance, and fuel burn are evaluated. For the sizing task, certain missions are designated to be used for design gross weight calculations; for transmission sizing; and for fuel tank sizing. The mission parameters include mission takeoff gross weight and useful load. For specified takeoff fuel weight with adjustable segments, the mission time or distance is adjusted so the fuel required for the mission equals the takeoff fuel weight. The mission iteration is on fuel weight or energy. Flight conditions are specified for the sizing task, and for the flight performance analysis. For the sizing task, certain flight conditions are designated to be used for design gross weight calculations; for transmission sizing; for maximum takeoff weight calculations; and for anti-torque or auxiliary thrust rotor sizing. The flight condition parameters include gross weight and useful load. For flight conditions and mission takeoff, the gross weight can be maximized, such that the power required equals the power available. A flight state is defined for each mission segment and each flight condition. The aircraft performance can be analyzed for the specified state, or a maximum effort performance can be identified. The maximum effort is specified in terms of a quantity such as best endurance or best range, and a variable such as speed, rate of climb, or altitude.
Alterations of collagen matrix in weight-bearing bones during skeletal unloading
NASA Technical Reports Server (NTRS)
Shiiba, M.; Arnaud, S. B.; Tanzawa, H.; Uzawa, K.; Yamauchi, M.
2001-01-01
Skeletal unloading induces loss of bone mineral density in weight-bearing bones. The objectives of this study were to characterize the post-translational modifications of collagen of weight-bearing bones subjected to hindlimb unloading for 8 weeks. In unloaded bones, tibiae and femurs, while the overall amino acid composition was essentially identical in the unloaded and control tibiae and femurs, the collagen cross-link profile showed significant differences. Two major reducible cross-links (analyzed as dihydroxylysinonorleucine and hydroxylysinonorleucine) were increased in the unloaded bones. In addition, the ratios of the former to the latter as well as pyridinoline to deoxypyridinoline were significantly decreased in the unloaded bones indicating a difference in the extent of lysine hydroxylation at the cross-linking sites between these two groups. These results indicate that upon skeletal unloading the relative pool of newly synthesized collagen is increased and it is post-translationally altered. The alteration could be associated with impaired osteoblastic differentiation induced by skeletal unloading that results in a mineralization defect.
Effects of immobilization on rat hind limb muscles under non-weight-bearing conditions
NASA Technical Reports Server (NTRS)
Jaspers, Stephen R.; Fagan, Julie M.; Satarug, Soisungwan; Cook, Paul H.; Tischler, Marc E.
1988-01-01
The effect of stretched and unstretched immobilization of a hind limb on the concentration and the metabolism of proteins in the hind-limb muscles of rats was investigated. The animals were divided into three groups: (1) weight-bearing controls, (2) tail-cast-suspended, and (3) suspended, with one hind limb immobilized with the ankle in dorsiflexion (30-40 deg angle) and the other freely moving. It was found that unloading the hind limbs for 6 days by tail cast suspension caused soleus to atrophy and reduced growth of the gastrocnemius and plantaris muscles; unloading resulted in a higher degradation rate and lower synthesis rate in both in vitro and in vivo. Chronic stretch of the unloaded soleus not only prevented its atrophy but led to significant hypertrophy, relative to weight-bearing controls, with increases in both the sarcoplasmic and myofibrillar protein fractions. Immobilizing one ankle in dorsiflexion prevented the inhibition of growth in the plantaris and gastrocnemius muscles due to unloading.
Antitumor activities of ginseng polysaccharide in C57BL/6 mice with Lewis lung carcinoma.
Zhou, Xiao; Shi, Huaiyin; Jiang, Gening; Zhou, Yongan; Xu, Jianfang
2014-12-01
In the present study, we prepared ginseng polysaccharide (GP) and evaluated its antitumor and immunomodulatory activities in C57BL/6 mice bearing with Lewis lung carcinoma (LLC). Administration of GP (50, 100, and 200 mg/kg) could not only significantly inhibit the growth of transplantable LLC tumor in C57BL/6 mice but also remarkably increase relative weight of spleen and thymus, splenocytes proliferation, and the ratio of CD4(+)/CD8(+) T lymphocyte in peripheral blood in LLC-bearing mice. Furthermore, the serum IL-2 and IFN-γ production and NK cytolytic activity were also prompted in LLC-bearing mice in response to GP treatment at three doses. Additionally, GP showed no side effects such as weight loss in body weight and internal organs (lung, liver, kidney, and heart) as well as inactivity during the experiment. Therefore, GP might be conveniently exploited to be good immune-stimulating modifiers and had the potential value for tumor therapy.
Yaw rate control of an air bearing vehicle
NASA Technical Reports Server (NTRS)
Walcott, Bruce L.
1989-01-01
The results of a 6 week project which focused on the problem of controlling the yaw (rotational) rate the air bearing vehicle used on NASA's flat floor facility are summarized. Contained within is a listing of the equipment available for task completion and an evaluation of the suitability of this equipment. The identification (modeling) process of the air bearing vehicle is detailed as well as the subsequent closed-loop control strategy. The effectiveness of the solution is discussed and further recommendations are included.
NASA Technical Reports Server (NTRS)
Braun, M. J.; Adams, M. L.; Mullen, R. L.
1985-01-01
A computer algorithm for simulation of hydrostatic journal bearing pressure-flow behavior has been generated. The effects taken into account are inertia, cavitation, variable properties (isothermal bearing) and roughness. The program has been specifically tailored for simulation of the hybrid bearing of the cryogenic turbopumps of the main shuttle engine. Due to the high pressure (515 psia) of the supply line no cavitation has been found. The influence of the roughness effects have been found to become important only when the surface-roughness order of magnitude is comparable with that of the bearing clearance itself. Pocket edge inertia and variable properties have been found to have quite an important influence upon the pocket pressure, field pressure distribution and lubricant mass flow.
Estimation of spectral kurtosis
NASA Astrophysics Data System (ADS)
Sutawanir
2017-03-01
Rolling bearings are the most important elements in rotating machinery. Bearing frequently fall out of service for various reasons: heavy loads, unsuitable lubrications, ineffective sealing. Bearing faults may cause a decrease in performance. Analysis of bearing vibration signals has attracted attention in the field of monitoring and fault diagnosis. Bearing vibration signals give rich information for early detection of bearing failures. Spectral kurtosis, SK, is a parameter in frequency domain indicating how the impulsiveness of a signal varies with frequency. Faults in rolling bearings give rise to a series of short impulse responses as the rolling elements strike faults, SK potentially useful for determining frequency bands dominated by bearing fault signals. SK can provide a measure of the distance of the analyzed bearings from a healthy one. SK provides additional information given by the power spectral density (psd). This paper aims to explore the estimation of spectral kurtosis using short time Fourier transform known as spectrogram. The estimation of SK is similar to the estimation of psd. The estimation falls in model-free estimation and plug-in estimator. Some numerical studies using simulations are discussed to support the methodology. Spectral kurtosis of some stationary signals are analytically obtained and used in simulation study. Kurtosis of time domain has been a popular tool for detecting non-normality. Spectral kurtosis is an extension of kurtosis in frequency domain. The relationship between time domain and frequency domain analysis is establish through power spectrum-autocovariance Fourier transform. Fourier transform is the main tool for estimation in frequency domain. The power spectral density is estimated through periodogram. In this paper, the short time Fourier transform of the spectral kurtosis is reviewed, a bearing fault (inner ring and outer ring) is simulated. The bearing response, power spectrum, and spectral kurtosis are plotted to visualize the pattern of each fault. Keywords: frequency domain Fourier transform, spectral kurtosis, bearing fault
USDA-ARS?s Scientific Manuscript database
The overall objective of this study was to examine the relationship between executive function, specifically decision making, and weight loss. We used the Iowa Gambling Task (IGT) to characterize decision making and compared performance on this task to weight loss in obese women (n=29) participatin...
Dr.LiTHO: a development and research lithography simulator
NASA Astrophysics Data System (ADS)
Fühner, Tim; Schnattinger, Thomas; Ardelean, Gheorghe; Erdmann, Andreas
2007-03-01
This paper introduces Dr.LiTHO, a research and development oriented lithography simulation environment developed at Fraunhofer IISB to flexibly integrate our simulation models into one coherent platform. We propose a light-weight approach to a lithography simulation environment: The use of a scripting (batch) language as an integration platform. Out of the great variety of different scripting languages, Python proved superior in many ways: It exhibits a good-natured learning-curve, it is efficient, available on virtually any platform, and provides sophisticated integration mechanisms for existing programs. In this paper, we will describe the steps, required to provide Python bindings for existing programs and to finally generate an integrated simulation environment. In addition, we will give a short introduction into selected software design demands associated with the development of such a framework. We will especially focus on testing and (both technical and user-oriented) documentation issues. Dr.LiTHO Python files contain not only all simulation parameter settings but also the simulation flow, providing maximum flexibility. In addition to relatively simple batch jobs, repetitive tasks can be pooled in libraries. And as Python is a full-blown programming language, users can add virtually any functionality, which is especially useful in the scope of simulation studies or optimization tasks, that often require masses of evaluations. Furthermore, we will give a short overview of the numerous existing Python packages. Several examples demonstrate the feasibility and productiveness of integrating Python packages into custom Dr.LiTHO scripts.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xu, Zuwei; Zhao, Haibo, E-mail: klinsmannzhb@163.com; Zheng, Chuguang
2015-01-15
This paper proposes a comprehensive framework for accelerating population balance-Monte Carlo (PBMC) simulation of particle coagulation dynamics. By combining Markov jump model, weighted majorant kernel and GPU (graphics processing unit) parallel computing, a significant gain in computational efficiency is achieved. The Markov jump model constructs a coagulation-rule matrix of differentially-weighted simulation particles, so as to capture the time evolution of particle size distribution with low statistical noise over the full size range and as far as possible to reduce the number of time loopings. Here three coagulation rules are highlighted and it is found that constructing appropriate coagulation rule providesmore » a route to attain the compromise between accuracy and cost of PBMC methods. Further, in order to avoid double looping over all simulation particles when considering the two-particle events (typically, particle coagulation), the weighted majorant kernel is introduced to estimate the maximum coagulation rates being used for acceptance–rejection processes by single-looping over all particles, and meanwhile the mean time-step of coagulation event is estimated by summing the coagulation kernels of rejected and accepted particle pairs. The computational load of these fast differentially-weighted PBMC simulations (based on the Markov jump model) is reduced greatly to be proportional to the number of simulation particles in a zero-dimensional system (single cell). Finally, for a spatially inhomogeneous multi-dimensional (multi-cell) simulation, the proposed fast PBMC is performed in each cell, and multiple cells are parallel processed by multi-cores on a GPU that can implement the massively threaded data-parallel tasks to obtain remarkable speedup ratio (comparing with CPU computation, the speedup ratio of GPU parallel computing is as high as 200 in a case of 100 cells with 10 000 simulation particles per cell). These accelerating approaches of PBMC are demonstrated in a physically realistic Brownian coagulation case. The computational accuracy is validated with benchmark solution of discrete-sectional method. The simulation results show that the comprehensive approach can attain very favorable improvement in cost without sacrificing computational accuracy.« less
NASA Technical Reports Server (NTRS)
1981-01-01
The specific objectives of the FY 1980-81 tasks are: (1) further refinements to the weighted aggregation procedure; (2) improved approaches for estimating within-stratum variance; (3) more intensive investigation of alternative sampling strategies such as full-frame sampling strategy, and (4) further developments in regard to a simulated approach for assessing the performance of the overall designed sampling and aggregation system.
van Ijsseldijk, Emiel A; Valstar, Edward R; Stoel, Berend C; de Ridder, Ruud; Nelissen, Rob G H H; Kaptein, Bart L
2014-04-01
Measuring the minimum-joint-space-width (mJSW) in total knee arthroplasty (TKA) in Roentgen stereophotogrammetric analysis (RSA) provides valuable information on polyethylene wear, a leading cause for TKA failure. Most existing studies use non-weight-bearing (NWB) patient positioning. The latter may compromise mJSW measurements due to knee laxity with subsequent non-contact between the TKA components. We investigated the difference in mJSW between weight-bearing (WB) and NWB images and the association with mediolateral (ML) knee stability. At one-year follow-up, 23 TKAs were included from an ongoing RSA study, and ML stability was evaluated. For each examination, the mJSW and femoral-tibial contact locations were measured. A linear regression model was used to analyze the association between the mJSW difference (NWB-WB) with the ML stability and contact locations. The mean mJSW difference was 0.28 mm medially and 0.20 mm laterally. Four TKAs had medium (5-9°) and 19 TKAs had high (<5°) ML stability. A higher mJSW difference was found for TKAs with medium stability (0.36 mm, P = 0.01). In conclusion, mJSW measurements in existing (NWB) RSA studies are influenced by knee laxity, but may still provide information on wear progression based on TKA with high ML stability. A direct comparison of mJSW measurements from WB and NWB data is not possible. © 2014 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
NASA Technical Reports Server (NTRS)
Linderman, J. K.; Talmadge, R. J.; Gosselink, K. L.; Tri, P. N.; Roy, R. R.; Grindeland, R. E.
1996-01-01
The purpose of this study was to investigate whether the soleus muscle undergoes atrophy and alterations in myosin heavy chain (MHC) composition during non-weight bearing in the absence of synergists. Thirty-two female rats were randomly assigned to four groups: control (C), synergistic ablation (ABL) of the gastrocnemius and plantaris muscles to overload the soleus muscle, hindlimb suspension (HLS), or a combination of synergistic ablation and hindlimb suspension (HLS-ABL). After 28 days of hindlimb suspension, soleus atrophy was more pronounced in HLS (58%) than in HLS-ABL (43%) rats. Compared to C rats, non-weight bearing decreased mixed and myofibrillar protein contents and Type I MHC 49%, 45%, and 7%, respectively, in HLS animals. In addition, de novo expression of fast Type IIx and Type IIb MHC (5% and 2%, respectively) was observed in HLS animals. Similarly, when compared to C rats, mixed and myofibrillar protein contents and Type I MHC decreased 43%, 46%, and 4%, respectively, in HLS-ABL animals. Also, de novo expression of Type IIx (4%) and IIb (1%) MHC was observed. Collectively, these data indicate that the loss of muscle protein and Type I MHC, and the de novo expression of Type IIx and Type IIb MHC in the rat soleus occur independently of the presence of synergists during non-weight bearing. Furthermore, these results confirm the contention that soleus mass and MHC expression are highly sensitive to alterations in mechanical load.
Cho, Yumi; Kim, Minkyu; Lee, Wanhee
2015-01-01
[Purpose] The purpose of this study was to determine the effect of proprioceptive training on foot progression angle, weight-bearing ratio, and knee adduction moment in patients with degenerative osteoarthritis of the knee. [Subjects] The subjects were 37 patients diagnosed with Kellgren-Lawrence grade 2 or 3 degenerative knee osteoarthritis. They were randomly allocated to three groups: a proprioceptive training group (PT group), quadriceps strengthening group (QS group), and control group. [Methods] The study parameters of the three groups were compared before and after a 12-week training period. Therapeutic exercises were performed twice per week for 12 weeks. Outcomes included the foot progression angle, weight-bearing ratio, and knee adduction moment. [Results] First, a significant difference in the foot progression angle was observed among the groups, significantly increasing in the PTG compared with the CG. Second, a significant difference in the weight-bearing ratio was observed among the groups, significantly increasing in the PTG compared with the CG. Third, a significant difference in the first peak knee adduction moment was observed among the groups, significantly decreasing in the PTG compared with the CG. [Conclusion] The results of the present study indicate that proprioceptive training increased the foot progression angle and weight-bearing ratio and decreased the first peak knee adduction moment. Moreover, incorporating proprioceptive training into a physical therapy exercise program could improve functional ability and delay the progression of degenerative osteoarthritis. PMID:25729170
Krapf, Daniel; Kaipel, Martin; Majewski, Martin
2012-09-01
Acute Achilles tendon ruptures are common sports injuries; however, treatment remains a clinical challenge. Studies show a superior effect of early mobilization and full weight bearing on tendon healing and clinical outcome; however, few data exist on structural and biomechanical characteristics in the early healing phase. This study investigated the histological and biomechanical characteristics of early mobilization and full weight bearing in an Achilles tendon rupture model. Eighty rats underwent dissection of a hindpaw Achilles tendon; 40 rats were treated conservatively and 40 underwent open repair of the transected Achilles tendon by suturing. Early mobilization and full weight bearing were allowed in both groups. At 1, 2, 4, and 8 weeks after tenotomy, tensile strength, stiffness, thickness, tissue characteristics (histological analysis), and length were determined. Dissected Achilles tendons healed in all animals during full weight-bearing early mobilization. One and 2 weeks after tenotomy, rats in the operative group showed increased tensile strength and stiffness compared with the nonoperative group. Repair-site diameters were increased at 1, 2, and 8 weeks after tenotomy. Tendon length was decreased in the operative group throughout observation, whereas the nonoperative group showed increased structural characteristics on the cellular level and a more homogeneous collagen distribution. Surgical treatment of dissected rat Achilles tendons showed superior biomechanical characteristics within the first 2 weeks. Conservative treatment resulted in superior histological findings but significant lengthening of the tendon in the early healing phase (weeks 1-8). Copyright 2012, SLACK Incorporated.
NASA Technical Reports Server (NTRS)
Parker, R. J.; Bamberger, E. N.; Nahm, A. H.
1983-01-01
Corrosion tests were run with AISI 52100, AISI M-50 and AMS 5794 under conditions that simulate the crevice corrosion found in aircraft ball and roller bearings rejected at overhaul for corrosion. Test specimens were fabricated that simulated the contacts of balls or rollers and the raceways. Corrosion cells were assembled in the presence of a lubricant contaminated with water and chloride ions. The cell was then thermally cycled between 339 K (150 F) and 276 K (37 F). The corrosion observed after 14 cycles was that of crevice and pitting corrosion typically found in aircraft bearings. AMS 5749 showed a very slight amount of corrosion. No appreciable differences were noted between AISI 52100 and AISI M-50, but both showed much greater corrosion than AMS 5749. The corrosion pits observed in AISI M-50 appeared to be fewer in number but generally deeper and larger than in AISI 52100.
NASA Technical Reports Server (NTRS)
Guman, W. J. (Editor)
1972-01-01
Design details are presented of the solid propellant pulsed plasma microthruster which was analyzed during the Task 1 effort. The design details presented show that the inherent functional simplicity underlying the flight proven LES-6 design can be maintained in the SMS systems design even with minimum weight constraints imposed. A 1293 hour uninterrupted vacuum test with the engineering thermal model, simulating an 18.8 to 33 g environment of the propellant, its feed system and electrode assembly, revealed that program thruster performance requirements could be met. This latter g environment is a more severe environment than will be ever encountered in the SMS spacecraft.
King, Lauren K.; March, Lyn; Anandacoomarasamy, Ananthila
2013-01-01
The most significant impact of obesity on the musculoskeletal system is associated with osteoarthritis (OA), a disabling degenerative joint disorder characterized by pain, decreased mobility and negative impact on quality of life. OA pathogenesis relates to both excessive joint loading and altered biomechanical patterns together with hormonal and cytokine dysregulation. Obesity is associated with the incidence and progression of OA of both weight-bearing and non weight-bearing joints, to rate of joint replacements as well as operative complications. Weight loss in OA can impart clinically significant improvements in pain and delay progression of joint structural damage. Further work is required to determine the relative contributions of mechanical and metabolic factors in the pathogenesis of OA. PMID:24056594
Maiti, Swatilekha; Mallick, Sanjaya Kumar; Bhutia, Sujit Kumar; Behera, Birendra; Mandal, Mohitosh; Maiti, Tapas K
2011-01-01
Previously, we reported the in vitro anticancer and immunomodulatory effect of a protein fraction designated as Cibacron blue affinity purified protein (CBAEP) obtained from the culinary-medicinal oyster mushroom, Pleurotus ostreatus. In the present study, we investigated the in vivo antitumor potential of CBAEP in different tumor-bearing mice models and studied the detailed mechanism of tumor regression in Dalton lymphoma (DL)-bearing mice. The lethal dose (LD50) of CBAEP was found to be 55 mg/kg body weight and sublethal doses (5 mg/kg and 10 mg/kg body weight) showed a prolonged tumor survival time in DL, Sarcoma-180, and B16F0 melanoma tumor-bearing mice. Further, CBAEP reduced about 35.68 and 51.43% DL cell growth in 5 and 10 mg/kg body weight, respectively. The in vivo CBAEP treatment showed an apoptotic feature as demonstrated in morphological study and sub-G0/G1 population in cell cycle and Western blot of DL cells. CBAEP also activated immunosuppression condition in DL tumor-bearing host. It also stimulated immune cells in the presence of nonspecific immunostunulator (LPS and ConA) ex vivo as well as enhanced Th1 response with production of TNF-α, IFN-γ, and IL-2. Moreover, it activated tumor-associated macrophages and NK cells. The present findings revealed the potent antitumor property of CBAEP, which might help in developing a new anticancer drug.
Heller, P.R.
1958-09-16
A thrust bearing suitable for use with a rotor or blower that is to rotate about a vertical axis is descrihed. A centrifagal jack is provided so thnt the device may opernte on one hearing at starting and lower speeds, and transfer the load to another bearing at higher speeds. A low viscosity fluid is used to lubricate the higher speed operation bearing, in connection with broad hearing -surfaces, the ability to withstand great loads, and a relatively high friction loss, as contraated to the lower speed operatio;n bearing which will withstand only light thrust loads but is sufficiently frictionfree to avoid bearing seizure during slow speed or startup operation. An axially aligned shaft pin provides the bearing surface for low rotational speeds, but at higher speed, weights operating against spring tension withdraw nthe shaft pin into the bearing proper and the rotor shaft comes in contact with the large bearing surfaces.
Shultz, Sandra J; Beynnon, Bruce D; Schmitz, Randy J
2009-06-01
Knee ligament injuries frequently happen when the joint transitions from non-weight bearing (NWB) to weight bearing (WB). To gain insight into the mechanism that produces these injuries, physically active females (N = 41) and males (N = 39) underwent measurement of coupled tibiofemoral joint displacements [anterior tibial translation (ATT) and varus-valgus and internal-external rotations] and neuromuscular responses as the knee transitioned from NWB to WB in response to a 40% body weight load applied under the control of gravity. The transition from NWB to WB produced no difference in ATT between males and females; however, significant sex-based differences were noted for both transverse and frontal plane knee motions. With the knee NWB, females were in a greater absolute valgus compared to males (6.6 vs. 5.0 degrees), and moved through greater varus motion than males during the transition from NW to WB (2.3 vs. 1.4 degrees), resulting in similar valgus alignment for both sexes at peak WB (4.3 vs. 3.6 degrees). In the transverse plane, the knees of females were positioned in more external rotation compared to males when NWB (1.4 vs. -0.3 degrees), then females externally rotated their knees while males internally rotated their knees during the transition from NWB to WB. This resulted in a 3.4 degrees difference in transverse plane knee position at peak WB (2.3 vs. -1.1 degrees). Our findings suggest that the coupled knee motions produced during the transition from NWB to WB are sex dependent, and may provide insight into the knee motion patterns that place females at increased risk of knee ligament injury. Copyright 2008 Orthopaedic Research Society
de Morais, Hely; de Fatima Silva, Flaviane; da Silva, Francemilson Goulart; Silva, Milene Ortiz; Graciano, Maria Fernanda Rodrigues; Martins, Maria Isabel Lovo; Carpinelli, Ângelo Rafael; Mazucco, Tânia Longo; Bazotte, Roberto Barbosa; de Souza, Helenir Medri
2017-07-05
Cachexia is the main cause of mortality in advanced cancer patients. We investigated the effects of insulin (INS) and glutamine dipeptide (GDP), isolated or associated, on cachexia and metabolic changes induced by Walker 256 tumor in rats. INS (NPH, 40 UI/kg, sc) or GDP (1.5g/kg, oral gavage) was once-daily administered during 11 days after tumor cell inoculation. GDP, INS or INS+GDP treatments did not influence the tumor growth. However, INS and INS+GDP prevented retroperitoneal fat wasting and body weight loss of tumor-bearing rats. In consistency, INS and INS+GDP prevented the increased expression of triacylglycerol lipase (ATGL) and hormone sensitive lipase (HSL), without changing the expression of tumor necrosis factor α (TNF-α) and interleukin-6 (IL-6) in the retroperitoneal adipose tissue of tumor-bearing rats. INS and INS+GDP also prevented anorexia and hyperlactatemia of tumor-bearing rats. However, INS and INS+GDP accentuated the loss of muscle mass (gastrocnemius, soleus and long digital extensor) without affecting the myostatin expression in the gastrocnemius muscle and blood corticosterone. GDP treatment did not promote beneficial effects. It can be concluded that treatment with INS (INS or INS+GDP), not with GDP, prevented fat wasting and weight loss in tumor-bearing rats without reducing tumor growth. These effects might be attributed to the reduction of lipases expression (ATGL and LHS) and increased food intake. The results show the physiological function of INS in the suppression of lipolysis induced by cachexia mediators in tumor-bearing rats. Copyright © 2017 Elsevier B.V. All rights reserved.
Wang, Xia; Jin, Xingzhong; Han, Weiyu; Cao, Yuelong; Halliday, Andrew; Blizzard, Leigh; Pan, Faming; Antony, Benny; Cicuttini, Flavia; Jones, Graeme; Ding, Changhai
2016-01-01
To describe the cross-sectional and longitudinal associations between knee regional effusion synovitis and knee pain in older adults. Data from a population-based random sample (n = 880, mean age 62 yrs, 50% women) were used. Baseline knee joint effusion synovitis was graded (0-3) using T2-weighted magnetic resonance imaging (MRI) in the suprapatellar pouch, central portion, posterior femoral recess, and subpopliteal recess. Effusion synovitis of the whole joint was defined as a score of ≥ 2 in any subregion. Other knee structural (including cartilage, bone marrow, and menisci) lesions were assessed by MRI at baseline. Knee pain was assessed by the Western Ontario and McMaster Universities Osteoarthritis Index questionnaire at baseline and 2.6 years later. Multivariable analyses were performed after adjustment for age, sex, body mass index, and other structural lesions. The prevalence of effusion synovitis was 67%. Suprapatellar pouch effusion synovitis was significantly and independently associated with increased total and nonweight-bearing knee pain in both cross-sectional and longitudinal analyses (for an increase in total knee pain of ≥ 5, RR 1.26 per grade, 95% CI 1.04-1.52), and increased weight-bearing knee pain in longitudinal analysis only. Effusion synovitis in posterior femoral recess and central portion were independently associated with increases in nonweight-bearing pain (RR 1.63 per grade, 95% CI 1.32-2.01 and RR 1.29 per grade, 95% CI 1.01-1.65, respectively) in longitudinal analyses only. Knee joint effusion synovitis has independent associations with knee pain in older adults. Suprapatellar pouch effusion synovitis is associated with nonweight-bearing and weight-bearing knee pain, while posterior femoral recess and central portion effusion synovitis are only associated with nonweight-bearing pain.
Kim, Harry K W; Aruwajoye, Olumide; Du, Justin; Kamiya, Nobuhiro
2014-09-17
Non-weight-bearing decreases the femoral head deformity but increases bone resorption without increasing bone formation in an experimental animal model of Legg-Calvé-Perthes disease. We sought to determine if local administration of bone morphogenetic protein (BMP)-2 with or without bisphosphonate can increase the bone formation during the non-weight-bearing treatment in the large animal model of Legg-Calvé-Perthes disease. Eighteen piglets were surgically induced with femoral head ischemia. Immediately following the surgery, all animals received an above-the-knee amputation to enforce local non-weight-bearing (NWB). One to two weeks later, six animals received local BMP-2 to the necrotic head (BMP group), six received local BMP-2 and ibandronate (BMP+IB group), and the remaining six received no treatment (NWB group). All animals were killed at eight weeks after the induction of ischemia. Radiographic, microcomputed tomography (micro-CT), and histomorphometric assessments were performed. Radiographic assessment showed that the femoral heads in the NWB, BMP, and BMP+IB groups had a decrease of 20%, 14%, and 10%, respectively, in their mean epiphyseal quotient in comparison with the normal control group. Micro-CT analyses showed significantly higher femoral head bone volume in the BMP+IB group than in the BMP group (p = 0.02) and the NWB group (p < 0.001). BMP+IB and BMP groups had a significantly higher trabecular number (p < 0.01) and lower trabecular separation (p < 0.02) than the NWB group. In addition, the osteoclast number per bone surface was significantly lower in the BMP+IB group compared with the NWB group. Calcein labeling showed significantly higher bone formation in the BMP and BMP+IB groups than in the NWB group (p < 0.05). Heterotopic ossification was found in the capsule of four hips in the BMP+IB group but not in the BMP group. Administration of BMP-2 with bisphosphonate best decreased bone resorption and increased new bone formation during non-weight-bearing treatment of ischemic osteonecrosis in a pig model, but heterotopic ossification is a concern. This preclinical study provides new evidence that BMP-2 with bisphosphonate can effectively prevent the extreme bone loss associated with the non-weight-bearing treatment and increase new bone formation in the femoral head in this animal model of ischemic osteonecrosis. Copyright © 2014 by The Journal of Bone and Joint Surgery, Incorporated.
Wang, Joon Ho; Shin, Jung Min; Kim, Hyun Ho; Kang, Seung-Hoon; Lee, Byung Hoon
2017-01-01
To evaluate the differences in the amount of varus malalignment and valgus (over) correction in relation to three different weight bearing conditions from whole leg AP radiographs (single-limb (SL) stance, double-limb (DL) stance, supine position (S)) before and after high tibial osteotomy (HTO), and to evaluate which alignment parameters affect the changes for patients in three different weight bearing conditions. A total of 40 consecutive patients (43 knees) with varus osteoarthritis underwent navigation assisted open wedge HTO. Mechanical axis angle (MA) was measured before and after surgery from hip-to-ankle radiographs taken with patients in three different weight bearing conditions. To find significant factors that affect the alignment differences, several variables including patient demographics, soft tissue laxity, pelvic obliquity, and ground mechanical axis deviation of tibia (calculated by the angle between two lines, tibial anatomical axis and weight-bearing line) were evaluated. Pre-operatively, mean MA measured on SL stance radiographs was significantly more varus than on DL stance (10.1° ± 2.4° and 8.0° ± 2.6°, respectively, p < 0.001), which was significantly more varus than on supine position (6.6° ± 2.6°, p < 0.001). Meanwhile, in patients with post-operatively valgus corrected knee, MA did not show the same pattern of change as with pre-operative varus knee. Mean MA measured on DL stance radiographs was more valgus than in supine position (-3.0 o ± 2.4 o and -2.6 o ± 3.1 o , p = 0.455), while mean MA on SL stance radiographs (-2.0 o ± 2.1 o ) was significantly less valgus than on DL stance (p = 0.002). The ground mechanical axis deviation of tibia showed a significant correlation with MA difference between SL and DL stance radiographs before (β = -0.341, p = 0.045) and after surgery (β = -0.536, p = 0.001). In pre-operative varus knee, the mean MA on SL stance was changed to more varus than on DL stance, which changed to less valgus in post-operative valgus knee. The understanding in discrepancy of alignment in different weight bearing conditions before and after HTO should be considered for the appropriate realignment of the limb. Level II Prospective comparative study.
NASA Technical Reports Server (NTRS)
Ishii, Masahiro; Sukanya, P.; Sato, Makoto
1994-01-01
This paper describes the construction of a virtual work space for tasks performed by two handed manipulation. We intend to provide a virtual environment that encourages users to accomplish tasks as they usually act in a real environment. Our approach uses a three dimensional spatial interface device that allows the user to handle virtual objects by hand and be able to feel some physical properties such as contact, weight, etc. We investigated suitable conditions for constructing our virtual work space by simulating some basic assembly work, a face and fit task. We then selected the conditions under which the subjects felt most comfortable in performing this task and set up our virtual work space. Finally, we verified the possibility of performing more complex tasks in this virtual work space by providing simple virtual models and then let the subjects create new models by assembling these components. The subjects can naturally perform assembly operations and accomplish the task. Our evaluation shows that this virtual work space has the potential to be used for performing tasks that require two-handed manipulation or cooperation between both hands in a natural manner.
Squeeze-Film Air Damping of a Five-Axis Electrostatic Bearing for Rotary Micromotors
Wang, Shunyue; Han, Fengtian; Sun, Boqian; Li, Haixia
2017-01-01
Air-film damping, which dominates over other losses, plays a significant role in the dynamic response of many micro-fabricated devices with a movable mass suspended by various bearing mechanisms. Modeling the damping characteristics accurately will be greatly helpful to the bearing design, control, and test in various micromotor devices. This paper presents the simulated and experimental squeeze-film air damping results of an electrostatic bearing for use in a rotary high-speed micromotor. It is shown that the boundary condition to solve the three-dimensional Reynolds equation, which governs the squeeze-film damping in the air gap between the rotor and its surrounding stator sealed in a three-layer evacuated cavity, behaves with strong cross-axis coupling characteristics. To accurately characterize the damping effect, a set of multiphysics finite-element simulations are performed by computing both the rotor velocity and the distribution of the viscous damping force acting on the rotor. The damping characteristics varying with several key structure parameters are simulated and discussed to optimize the device structure for desirable rotor dynamics. An electrical measurement method is also proposed and applied to validate the numerical results of the damping coefficients experimentally. Given that the frequency response of the electric bearing is critically dependent on the damping coefficients at atmospheric pressure, a solution to the air-film damping measurement problem is presented by taking approximate curve fitting of multi-axis experimental frequency responses. The measured squeeze-film damping coefficients for the five-axis electric bearing agrees well with the numerical solutions. This indicates that numerical multiphysics simulation is an effective method to accurately examine the air-film damping effect for complex device geometry and arbitrary boundary condition. The accurate damping coefficients obtained by FEM simulation will greatly simplify the design of the five-axis bearing control system and facilitate the initial suspension test of the rotor for various micromotor devices. PMID:28505089
Squeeze-Film Air Damping of a Five-Axis Electrostatic Bearing for Rotary Micromotors.
Wang, Shunyue; Han, Fengtian; Sun, Boqian; Li, Haixia
2017-05-13
Air-film damping, which dominates over other losses, plays a significant role in the dynamic response of many micro-fabricated devices with a movable mass suspended by various bearing mechanisms. Modeling the damping characteristics accurately will be greatly helpful to the bearing design, control, and test in various micromotor devices. This paper presents the simulated and experimental squeeze-film air damping results of an electrostatic bearing for use in a rotary high-speed micromotor. It is shown that the boundary condition to solve the three-dimensional Reynolds equation, which governs the squeeze-film damping in the air gap between the rotor and its surrounding stator sealed in a three-layer evacuated cavity, behaves with strong cross-axis coupling characteristics. To accurately characterize the damping effect, a set of multiphysics finite-element simulations are performed by computing both the rotor velocity and the distribution of the viscous damping force acting on the rotor. The damping characteristics varying with several key structure parameters are simulated and discussed to optimize the device structure for desirable rotor dynamics. An electrical measurement method is also proposed and applied to validate the numerical results of the damping coefficients experimentally. Given that the frequency response of the electric bearing is critically dependent on the damping coefficients at atmospheric pressure, a solution to the air-film damping measurement problem is presented by taking approximate curve fitting of multi-axis experimental frequency responses. The measured squeeze-film damping coefficients for the five-axis electric bearing agrees well with the numerical solutions. This indicates that numerical multiphysics simulation is an effective method to accurately examine the air-film damping effect for complex device geometry and arbitrary boundary condition. The accurate damping coefficients obtained by FEM simulation will greatly simplify the design of the five-axis bearing control system and facilitate the initial suspension test of the rotor for various micromotor devices.
A compact magnetic bearing for gimballed momentum wheel
NASA Technical Reports Server (NTRS)
Yabu-Uchi, K.; Inoue, M.; Akishita, S.; Murakami, C.; Okamoto, O.
1983-01-01
A three axis controlled magnetic bearing and its application to a momentum wheel are described. The four divided stators provide a momentum wheel with high reliability, low weight, large angular momentum storage capacity, and gimbal control. Those characteristics are desirable for spacecraft attitude control.
19 CFR 133.22 - Restrictions on importation of articles bearing copying or simulating trademarks.
Code of Federal Regulations, 2010 CFR
2010-04-01
... copying or simulating trademarks. 133.22 Section 133.22 Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF THE TREASURY TRADEMARKS, TRADE NAMES, AND COPYRIGHTS Importations Bearing Registered and/or Recorded Trademarks or Recorded Trade Names § 133.22 Restrictions on...
DOT National Transportation Integrated Search
2015-08-01
The overall goal of this project is the experimental evaluation and design of unfilled and concrete-filled FRP composite piles for load-bearing in bridges. This report covers Task 4A, Design Specifications. : Structural design specifications are base...
NASA Technical Reports Server (NTRS)
Newman, Dava J.
1995-01-01
Simulations of astronaut motions during extravehicular activity (EVA) tasks were performed using computational multibody dynamics methods. The application of computational dynamic simulation to EVA was prompted by the realization that physical microgravity simulators have inherent limitations: viscosity in neutral buoyancy tanks; friction in air bearing floors; short duration for parabolic aircraft; and inertia and friction in suspension mechanisms. These limitations can mask critical dynamic effects that later cause problems during actual EVA's performed in space. Methods of formulating dynamic equations of motion for multibody systems are discussed with emphasis on Kane's method, which forms the basis of the simulations presented herein. Formulation of the equations of motion for a two degree of freedom arm is presented as an explicit example. The four basic steps in creating the computational simulations were: system description, in which the geometry, mass properties, and interconnection of system bodies are input to the computer; equation formulation based on the system description; inverse kinematics, in which the angles, velocities, and accelerations of joints are calculated for prescribed motion of the endpoint (hand) of the arm; and inverse dynamics, in which joint torques are calculated for a prescribed motion. A graphical animation and data plotting program, EVADS (EVA Dynamics Simulation), was developed and used to analyze the results of the simulations that were performed on a Silicon Graphics Indigo2 computer. EVA tasks involving manipulation of the Spartan 204 free flying astronomy payload, as performed during Space Shuttle mission STS-63 (February 1995), served as the subject for two dynamic simulations. An EVA crewmember was modeled as a seven segment system with an eighth segment representing the massive payload attached to the hand. For both simulations, the initial configuration of the lower body (trunk, upper leg, and lower leg) was a neutral microgravity posture. In the first simulation, the payload was manipulated around a circular trajectory of 0.15 m radius in 10 seconds. It was found that the wrist joint theoretically exceeded its ulnal deviation limit by as much as 49. 8 deg and was required to exert torques as high as 26 N-m to accomplish the task, well in excess of the wrist physiological limit of 12 N-m. The largest torque in the first simulation, 52 N-m, occurred in the ankle joint. To avoid these problems, the second simulation placed the arm in a more comfortable initial position and the radius and speed of the circular trajectory were reduced by half. As a result, the joint angles and torques were reduced to values well within their physiological limits. In particular, the maximum wrist torque for the second simulation was only 3 N-m and the maximum ankle torque was only 6 N-m.
Stress fracture of ulna due to excessive push-ups.
Meena, Sanjay; Rastogi, Devarshi; Solanki, Bipin; Chowdhury, Buddhadev
2014-01-01
Stress fractures are most common in the weight-bearing bones of the lower extremities and spine, but are rarely found in non-weight-bearing bones of the body. Stress fracture of the ulna is extremely rare. We report a case of complete stress fracture of ulna caused due to excessive push ups in a young athlete. Conservative management was successful in healing of fracture and returning this patient back to his previous activity level. Physician should have high index of suspicion, whenever they encounter a young athlete complaining of forearm pain.
Assessment of executive functioning in binge-eating disorder independent of weight status.
Eneva, Kalina T; Arlt, Jean M; Yiu, Angelina; Murray, Susan M; Chen, Eunice Y
2017-08-01
Executive functioning (EF) problems may serve as vulnerability or maintenance factors for Binge-Eating Disorder (BED). However, it is unclear if EF problems observed in BED are related to overweight status or BED status. The current study extends this literature by examining EF in overweight and normal-weight BED compared to weight-matched controls. Participants were normal-weight women with BED (n = 23), overweight BED (n = 32), overweight healthy controls (n = 48), and normal-weight healthy controls (n = 29). The EF battery utilized tests from the National Institutes of Health (NIH) Toolbox and Delis-Kaplan Executive Function System (D-KEFS). After controlling for years of education and minority status, overweight individuals performed more poorly than normal-weight individuals on a task of cognitive flexibility requiring generativity (p < .01), and speed on psychomotor performance tasks (p = .01). Normal-weight and overweight BED performed worse on working memory tasks compared to controls (p = .04). Unexpectedly, normal-weight BED individuals out-performed all other groups on an inhibitory control task (p < .01). No significant differences were found between the four groups on tasks of planning. Regardless of weight status, BED is associated with working memory problems. Replication of the finding that normal-weight BED is associated with enhanced inhibitory control is needed. © 2017 Wiley Periodicals, Inc.
Bone and hormonal changes induced by skeletal unloading in the mature male rat
NASA Technical Reports Server (NTRS)
Dehority, W.; Halloran, B. P.; Bikle, D. D.; Curren, T.; Kostenuik, P. J.; Wronski, T. J.; Shen, Y.; Rabkin, B.; Bouraoui, A.; Morey-Holton, E.
1999-01-01
To determine whether the rat hindlimb elevation model can be used to study the effects of spaceflight and loss of gravitational loading on bone in the adult animal, and to examine the effects of age on bone responsiveness to mechanical loading, we studied 6-mo-old rats subjected to hindlimb elevation for up to 5 wk. Loss of weight bearing in the adult induced a mild hypercalcemia, diminished serum 1,25-dihydroxyvitamin D, decreased vertebral bone mass, and blunted the otherwise normal increase in femoral mass associated with bone maturation. Unloading decreased osteoblast numbers and reduced periosteal and cancellous bone formation but had no effect on bone resorption. Mineralizing surface, mineral apposition rate, and bone formation rate decreased during unloading. Our results demonstrate the utility of the adult rat hindlimb elevation model as a means of simulating the loss of gravitational loading on the skeleton, and they show that the effects of nonweight bearing are prolonged and have a greater relative effect on bone formation in the adult than in the young growing animal.
Brydges, Ryan; Hatala, Rose; Mylopoulos, Maria
2016-07-01
Simulation-based training is currently embedded in most health professions education curricula. Without evidence for how trainees think about their simulation-based learning, some training techniques may not support trainees' learning strategies. This study explored how residents think about and self-regulate learning during a lumbar puncture (LP) training session using a simulator. In 2010, 20 of 45 postgraduate year 1 internal medicine residents attended a mandatory procedural skills training boot camp. Independently, residents practiced the entire LP skill on a part-task trainer using a clinical LP tray and proper sterile technique. We interviewed participants regarding how they thought about and monitored their learning processes, and then we conducted a thematic analysis of the interview data. The analysis suggested that participants considered what they could and could not learn from the simulator; they developed their self-confidence by familiarizing themselves with the LP equipment and repeating the LP algorithmic steps. Participants articulated an idiosyncratic model of learning they used to interpret the challenges and successes they experienced. Participants reported focusing on obtaining cerebrospinal fluid and memorizing the "routine" version of the LP procedure. They did not report much thinking about their learning strategies (eg, self-questioning). During simulation-based training, residents described assigning greater weight to achieving procedural outcomes and tended to think that the simulated task provided them with routine, generalizable skills. Over this typical 1-hour session, trainees did not appear to consider their strategic mindfulness (ie, awareness and use of learning strategies).
Effect of Food Deprivation on a Delayed Nonmatch-to-place T-maze Task
Jang, Eun-Hae; Ahn, Seo-Hee; Lee, Ye-Seul; Lee, Hye-Ryeon
2013-01-01
Food deprivation can affect performance on difficult cognitive task, such as the delayed nonmatch-to-place T-maze task (DNMT). The importance of food deprivation on maintaining high motivation for DNMT task has been emphasized, but not many studies have investigated the optimal conditions for depriving rodents to maximize performance. Establishing appropriate conditions for food deprivation is necessary to maintain DNMT task motivation. We applied different conditions of food deprivation (1-h food restriction vs. 1.5-g food restriction; single caging vs. group caging) and measured body weight and the number of correct choices that 8-week-old C57BL/6J mice made during the DNMT task. The 1.5-g food restriction group maintained 76.0±0.6% of their initial body weight, but the final body weight of the 1-h food restriction condition group was reduced to 62.2±0.8% of their initial body weight. These results propose that 1.5-g food restriction condition is effective condition for maintaining both body weight and motivation to complete the DNMT task. PMID:23833561
Static and Dynamic Analysis in Design of Exoskeleton Structure
NASA Astrophysics Data System (ADS)
Ivánkova, Ol'ga; Méri, Dávid; Vojteková, Eva
2017-10-01
This paper introduces a numerical experiment of creating the load bearing system of a high rise building. When designing the high-rise building, it is always an important task to find the right proportion between the height of the building and its perceptive width from the various angles of street view. Investigated high rise building in this article was designed according to these criteria. The load bearing structure of the analysed object consists of a reinforced core, plates and steel tubes of an exoskeleton. Eight models of the building were created using the spatial variant of FEM in Scia Engineer Software. Individual models varied in number and dimensions of diagrids in the exoskeleton. In the models, loadings due to the own weight, weight of external glass cladding, and due to the wind according to the Standard, have been considered. The building was loaded by wind load from all four main directions with respect to its shape. Wind load was calculated using the 3D wind generator, which is a part of the Scia Engineer Software. For each model the static analysis was performed. Its most important criterion was the maximum or minimum horizontal displacement (rotation) of the highest point of the building. This displacement was compared with the limit values of the displacement of the analysed high-rise building. By step-by-step adding diagrids and optimizing their dimensions the building model was obtained that complied with the criteria of the Limit Serviceability State. The last model building was assessed also for the Ultimate Limit State. This model was loaded also by seismic loads for comparison with the load due to the wind.
NASA Technical Reports Server (NTRS)
Padovan, J.; Adams, M.; Fertis, J.; Zeid, I.; Lam, P.
1982-01-01
Finite element codes are used in modelling rotor-bearing-stator structure common to the turbine industry. Engine dynamic simulation is used by developing strategies which enable the use of available finite element codes. benchmarking the elements developed are benchmarked by incorporation into a general purpose code (ADINA); the numerical characteristics of finite element type rotor-bearing-stator simulations are evaluated through the use of various types of explicit/implicit numerical integration operators. Improving the overall numerical efficiency of the procedure is improved.
Off-line simulation inspires insight: A neurodynamics approach to efficient robot task learning.
Sousa, Emanuel; Erlhagen, Wolfram; Ferreira, Flora; Bicho, Estela
2015-12-01
There is currently an increasing demand for robots able to acquire the sequential organization of tasks from social learning interactions with ordinary people. Interactive learning-by-demonstration and communication is a promising research topic in current robotics research. However, the efficient acquisition of generalized task representations that allow the robot to adapt to different users and contexts is a major challenge. In this paper, we present a dynamic neural field (DNF) model that is inspired by the hypothesis that the nervous system uses the off-line re-activation of initial memory traces to incrementally incorporate new information into structured knowledge. To achieve this, the model combines fast activation-based learning to robustly represent sequential information from single task demonstrations with slower, weight-based learning during internal simulations to establish longer-term associations between neural populations representing individual subtasks. The efficiency of the learning process is tested in an assembly paradigm in which the humanoid robot ARoS learns to construct a toy vehicle from its parts. User demonstrations with different serial orders together with the correction of initial prediction errors allow the robot to acquire generalized task knowledge about possible serial orders and the longer term dependencies between subgoals in very few social learning interactions. This success is shown in a joint action scenario in which ARoS uses the newly acquired assembly plan to construct the toy together with a human partner. Copyright © 2015 Elsevier Ltd. All rights reserved.
DOT National Transportation Integrated Search
2015-07-01
The overall goal of this project is the experimental evaluation and design of unfilled and concrete-filled FRP composite piles for load-bearing in bridges. This report covers Task 4B, Materials and Construction Specifications. : This technical report...
DOT National Transportation Integrated Search
2014-06-01
The overall goal of this project is the experimental evaluation and design of unfilled and concrete-filled FRP : composite piles for load-bearing in bridges. This report covers Task 3, FRP Composite Pile Flexural Testing. : Hollow and concrete filled...
DOT National Transportation Integrated Search
2015-04-01
The overall goal of this project is the experimental evaluation and design of unfilled and concrete-filled FRP : composite piles for load-bearing in bridges. This report covers Task 6, FRP Composite Pile Axial Compression : Testing. : Hollow and conc...
DOT National Transportation Integrated Search
2015-05-01
The overall goal of this project is the experimental evaluation and design of unfilled and concrete-filled FRP composite piles for load-bearing in bridges. This report covers Task 5, Laminate Durability Testing. : Mechanical properties of the FRP mat...
DOT National Transportation Integrated Search
2014-10-01
The overall goal of this project is the experimental evaluation and design of unfilled and concrete-filled FRP : composite piles for load-bearing in bridges. This report covers Task 1, Mechanical Properties of FRP Piles. : Mechanical and geotechnic...
Li, Lian-Hui; Mo, Rong
2015-01-01
The production task queue has a great significance for manufacturing resource allocation and scheduling decision. Man-made qualitative queue optimization method has a poor effect and makes the application difficult. A production task queue optimization method is proposed based on multi-attribute evaluation. According to the task attributes, the hierarchical multi-attribute model is established and the indicator quantization methods are given. To calculate the objective indicator weight, criteria importance through intercriteria correlation (CRITIC) is selected from three usual methods. To calculate the subjective indicator weight, BP neural network is used to determine the judge importance degree, and then the trapezoid fuzzy scale-rough AHP considering the judge importance degree is put forward. The balanced weight, which integrates the objective weight and the subjective weight, is calculated base on multi-weight contribution balance model. The technique for order preference by similarity to an ideal solution (TOPSIS) improved by replacing Euclidean distance with relative entropy distance is used to sequence the tasks and optimize the queue by the weighted indicator value. A case study is given to illustrate its correctness and feasibility.
Li, Lian-hui; Mo, Rong
2015-01-01
The production task queue has a great significance for manufacturing resource allocation and scheduling decision. Man-made qualitative queue optimization method has a poor effect and makes the application difficult. A production task queue optimization method is proposed based on multi-attribute evaluation. According to the task attributes, the hierarchical multi-attribute model is established and the indicator quantization methods are given. To calculate the objective indicator weight, criteria importance through intercriteria correlation (CRITIC) is selected from three usual methods. To calculate the subjective indicator weight, BP neural network is used to determine the judge importance degree, and then the trapezoid fuzzy scale-rough AHP considering the judge importance degree is put forward. The balanced weight, which integrates the objective weight and the subjective weight, is calculated base on multi-weight contribution balance model. The technique for order preference by similarity to an ideal solution (TOPSIS) improved by replacing Euclidean distance with relative entropy distance is used to sequence the tasks and optimize the queue by the weighted indicator value. A case study is given to illustrate its correctness and feasibility. PMID:26414758
Ichihara, Hideaki; Kuwabara, Keiji; Matsumoto, Yoko
2017-11-01
Previous evidence demonstrates that trehalose liposomes (DMTreC14) composed of L-α-dimyristoylphosphatidylcholine (DMPC) and α-D-glycopyranosyl-α-D-glucopyranoside monomyristate (TreC14) inhibit proliferation and invasion on lung carcinoma (A549 cells) in vitro. Here, we aimed to investigate suppressive effects of DMTreC14 on the growth of tumor on human lung carcinoma bearing mice. DMTreC14 composed of 30 mol% DMPC and 70 mol% TreC14 were prepared by the sonication method. Anti-tumor activities of DMTreC14 using the subcutaneous and orthotopic graft-bearing mice of A549 cells were investigated in vivo. The remarkable reduction of volume and weight in subcutaneous tumors on subcutaneous lung carcinoma-bearing mice topically administrated with DMTreC14 were obtained. Apoptotic-positive cells in the subcutaneous tumor slice of subcutaneous lung carcinoma-bearing mice topically administrated with DMTreC14 were observed using TUNEL staining. Lung weights on the orthotopic graft-bearing mice of lung carcinoma intravenously administrated with DMTreC14 were markedly decreased compared to those of the control group. Remarkable decrease in dimensions of tumor area of lung on the orthotopic graft-bearing mice of lung carcinoma intravenously administrated with DMTreC14 was obtained in histological analysis using the hematoxylin and eosin staining. Remarkably high anti-tumor activities of DMTreC14 for the subcutaneous and orthotopic graft-bearing mice of lung carcinoma accompanied with apoptosis were revealed for the first time in vivo. Copyright© 2017, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.
Iizuka, Norio; Hazama, Shoichi; Yoshimura, Kiyoshi; Yoshino, Shigefumi; Tangoku, Akira; Miyamoto, Koji; Okita, Kiwamu; Oka, Masaaki
2002-05-10
We previously showed that the natural herb Coptidis rhizoma has an anticachectic effect in nude mice bearing human esophageal cancer cells. We further investigated this phenomenon by examining the anticachectic effect of C. rhizoma in syngeneic mice bearing colon 26/clone 20 carcinoma cells, which cause IL-6-related cachexia after cell injection. We evaluated nutritional parameters such as serum glucose level and wasting of adipose tissue and muscle in tumor-bearing and non-tumor-bearing mice treated with C. rhizoma (CR) supplement or a normal diet. IL-6 levels in those mice were quantified by ELISA and real-time RT-PCR. CR supplementation significantly attenuated weight loss in tumor-bearing mice without changing food intake or tumor growth. Furthermore, these mice maintained good nutritional status. IL-6 mRNA levels in tumors and spleens and IL-6 protein levels in tumors and sera were significantly lower in tumor-bearing mice treated with CR supplement than in those treated with a normal diet. CR supplementation did not affect food intake, body weight, nutritional parameters and IL-6 levels in non-tumor-bearing mice. An in vitro study showed that C. rhizoma and its major component, berberine, inhibited IL-1-induced IL-6 mRNA expression in a dose-dependent manner in colon 26/clone 20 cells. Our results showed that C. rhizoma exerts an anticachectic effect on colon 26/clone 20-transplanted mice and that its effect is associated with tumor IL-6 production. We also suggest that its effect might be due to berberine. Copyright 2002 Wiley-Liss, Inc.
NASA Technical Reports Server (NTRS)
DellaCorte, Christopher; Radil, Kevin C.; Bruckner, Robert J.; Howard, S. Adam
2007-01-01
Foil gas bearings are self-acting hydrodynamic bearings made from sheet metal foils comprised of at least two layers. The innermost top foil layer traps a gas pressure film that supports a load while a layer or layers underneath provide an elastic foundation. Foil bearings are used in many lightly loaded, high-speed turbo-machines such as compressors used for aircraft pressurization, and small micro-turbines. Foil gas bearings provide a means to eliminate the oil system leading to reduced weight and enhanced temperature capability. The general lack of familiarity of the foil bearing design and manufacturing process has hindered their widespread dissemination. This paper reviews the publicly available literature to demonstrate the design, fabrication and performance testing of both first and second generation bump style foil bearings. It is anticipated that this paper may serve as an effective starting point for new development activities employing foil bearing technology.
Parallel Online Temporal Difference Learning for Motor Control.
Caarls, Wouter; Schuitema, Erik
2016-07-01
Temporal difference (TD) learning, a key concept in reinforcement learning, is a popular method for solving simulated control problems. However, in real systems, this method is often avoided in favor of policy search methods because of its long learning time. But policy search suffers from its own drawbacks, such as the necessity of informed policy parameterization and initialization. In this paper, we show that TD learning can work effectively in real robotic systems as well, using parallel model learning and planning. Using locally weighted linear regression and trajectory sampled planning with 14 concurrent threads, we can achieve a speedup of almost two orders of magnitude over regular TD control on simulated control benchmarks. For a real-world pendulum swing-up task and a two-link manipulator movement task, we report a speedup of 20× to 60× , with a real-time learning speed of less than half a minute. The results are competitive with state-of-the-art policy search.
Limit cycles of a flexible shaft with hydrodynamic journal bearings in unstable regimes
NASA Technical Reports Server (NTRS)
Brown, R. D.; Black, H. F.
1980-01-01
A symmetric 3 mass rotor supported on hydrodynamic bearings is described. An approximate method of representing finite bearings is used to calculate bearing forces. As the method sums forces from a number of independent circular lobes lemon 3 and 4 lobe bearings are taken into account. The calculations are based on an axial groove bearing. Linear analysis precedes nonlinear simulation of some unstable conditions. The demonstration of small limit cycles suggests that necessarily flexible rotors e.g., helicopter tail rotors, may be practical without either tilt pad bearings or external dampers.
NASA Technical Reports Server (NTRS)
Flowers, George T.
1995-01-01
This semiannual status report lists specific accomplishments made on the research of the influence of backup bearings and support structure dynamics on the behavior of rotors with active supports. Papers have been presented representing work done on the T-501 engine model; an experimental/simulation study of auxiliary bearing rotordynamics; and a description of a rotordynamical model for a magnetic bearing supported rotor system, including auxiliary bearing effects. A finite element model for a foil bearing has been developed. Additional studies of rotor/bearing/housing dynamics are currently being performed as are studies of the effects of sideloading on auxiliary bearing rotordynamics using the magnetic bearing supported rotor model.
van Lieshout, Remko; Pisters, Martijn F.; Vanwanseele, Benedicte; de Bie, Rob A.; Wouters, Eveline J.; Stukstette, Mirelle J.
2016-01-01
Background Partial weight bearing is frequently instructed by physical therapists in patients after lower-limb trauma or surgery. The use of biofeedback devices seems promising to improve the patient’s compliance with weight-bearing instructions. SmartStep and OpenGo-Science are biofeedback devices that provide real-time feedback. For a successful implementation, usability of the devices is a critical aspect and should be tested from a user’s perspective. Aim To describe the usability from the physical therapists’ and a patients’ perspective of Smartstep and OpenGo-Science to provide feedback on partial weight bearing during supervised rehabilitation of patients after lower-limb trauma or surgery. Methods In a convergent mixed-methods design, qualitative and quantitative data were collected. Usability was subdivided into user performance, satisfaction and acceptability. Patients prescribed with partial weight bearing and their physical therapists were asked to use SmartStep and OpenGo-Science during supervised rehabilitation. Usability was qualitatively tested by a think-aloud method and a semi-structured interview and quantitatively tested by the System-Usability-Scale (SUS) and closed questions. For the qualitative data thematic content analyses were used. Results Nine pairs of physical therapists and their patients participated. The mean SUS scores for patients and physical therapists were for SmartStep 70 and 53, and for OpenGo-Science 79 and 81, respectively. Scores were interpreted with the Curved Grading Scale. The qualitative data showed that there were mixed views and perceptions from patients and physical therapists on satisfaction and acceptability. Conclusion This study gives insight in the usability of two biofeedback devices from the patient’s and physical therapist’s perspective. The overall usability from both perspectives seemed to be acceptable for OpenGo-Science. For SmartStep, overall usability seemed only acceptable from the patient’s perspective. Implication The study findings could help clinicians to decide which biofeedback device is appropriate for their given situation and provide information for future development of biofeedback devices. PMID:27798674
Mahato, Niladri Kumar; Sybert, Daryl; Law, Tim; Clark, Brian
2017-05-01
Our objective was to use an open weight-bearing MRI to identify the effects of different loading conditions on the inter-vertebral anatomy of the lumbar spine in a post-discectomy recurrent lumbar disc herniation patient. A 43-year-old male with a left-sided L5-S1 post-decompression re-herniation underwent MR imaging in three spine-loading conditions: (1) supine, (2) weight-bearing on standing (WB), and (3) WB with 10 % of body mass axial loading (WB + AL) (5 % through each shoulder). A segmentation-based proprietary software was used to calculate and compare linear dimensions, angles and cross sections across the lumbar spine. The L5 vertebrae showed a 4.6 mm posterior shift at L5-S1 in the supine position that changed to an anterior translation >2.0 mm on WB. The spinal canal sagittal thickness at L5-S1 reduced from supine to WB and WB + AL (13.4, 10.6, 9.5 mm) with corresponding increases of 2.4 and 3.5 mm in the L5-S1 disc protrusion with WB and WB + AL, respectively. Change from supine to WB and WB + AL altered the L5-S1 disc heights (10.2, 8.6, 7.0 mm), left L5-S1 foramen heights (12.9, 11.8, 10.9 mm), L5-S1 segmental angles (10.3°, 2.8°, 4.3°), sacral angles (38.5°, 38.3°, 40.3°), L1-L3-L5 angles (161.4°, 157.1°, 155.1°), and the dural sac cross sectional areas (149, 130, 131 mm 2 ). Notably, the adjacent L4-L5 segment demonstrated a retro-listhesis >2.3 mm on WB. We observed that with weight-bearing, measurements indicative of spinal canal narrowing could be detected. These findings suggest that further research is warranted to determine the potential utility of weight-bearing MRI in clinical decision-making.
Hirschmann, Anna; Buck, Florian M; Herschel, Ramin; Pfirrmann, Christian W A; Fucentese, Sandro F
2017-03-01
To prospectively compare patellofemoral and tibiofemoral articulations in the upright weight-bearing position with different degrees of flexion using CT in order to gain a more thorough understanding of the development of diseases of the knee joint in a physiological position. CT scans of the knee in 0°, 30°, 60° flexion in the upright weight-bearing position and in 120° flexion upright without weight-bearing were obtained of 10 volunteers (mean age 33.7 ± 6.1 years; range 24-41) using a cone-beam extremity-CT. Two independent readers quantified tibiofemoral and patellofemoral rotation, tibial tuberosity-trochlear groove distance (TTTG) and patellofemoral distance. Tibiofemoral contact points were assessed in relation to the anteroposterior distance of the tibial plateau. Significant differences between degrees of flexion were sought using Wilcoxon signed-rank test (P < 0.05). With higher degrees of flexion, internal tibiofemoral rotation increased (0°/120° flexion; mean, 0.5° ± 4.5/22.4° ± 7.6); external patellofemoral rotation decreased (10.6° ± 7.6/1.6° ± 4.2); TTTG decreased (11.1 mm ±3.7/-2.4 mm ±6.4) and patellofemoral distance decreased (38.7 mm ±3.0/21.0 mm ±7.0). The CP shifted posterior, more pronounced laterally. Significant differences were found for all measurements at all degrees of flexion (P = 0.005-0.037), except between 30° and 60°. ICC was almost perfect (0.80-0.99), except for the assessment of the CP (0.20-0.96). Knee joint articulations change significantly during flexion using upright weight-bearing CT. Progressive internal tibiofemoral rotation leads to a decrease in the TTTG and a posterior shift of the contact points in higher degrees of flexion. This elucidates patellar malalignment predominantly close to extension and meniscal tears commonly affecting the posterior horns.
NASA Technical Reports Server (NTRS)
Turner, R. T.; Evans, G. L.; Cavolina, J. M.; Halloran, B.; Morey-Holton, E.
1998-01-01
Gonadal insufficiency and reduced mechanical usage are two important risk factors for osteoporosis. The beneficial effects of PTH therapy to reverse the estrogen deficiency-induced bone loss in the laboratory rat are well known, but the influence of mechanical usage in this response has not been established. In this study, the effects of programed administration of PTH on cancellous bone volume and turnover at the proximal tibial metaphysis were determined in hindlimb-unloaded, ovariectomized (OVX), 3-month-old Sprague-Dawley rats. PTH was administered to weight-bearing and hindlimb-unloaded OVX rats with osmotic pumps programed to deliver 20 microg human PTH (approximately 80 microg/kg x day) during a daily 1-h infusion for 7 days. Compared with sham-operated rats, OVX increased longitudinal and radial bone growth, increased indexes of cancellous bone turnover, and resulted in net resorption of cancellous bone. Hindlimb unloading of OVX rats decreased longitudinal and radial bone growth, decreased osteoblast number, increased osteoclast number, and resulted in a further decrease in cancellous bone volume compared with those in weight-bearing OVX rats. Programed administration of PTH had no effect on either radial or longitudinal bone growth in weight-bearing and hindlimb-unloaded OVX rats. PTH treatment had dramatic effects on selected cancellous bone measurements; PTH maintained cancellous bone volume in OVX weight-bearing rats and greatly reduced cancellous bone loss in OVX hindlimb-unloaded rats. In the latter animals, PTH treatment prevented the hindlimb unloading-induced reduction in trabecular thickness, but the hormone was ineffective in preventing either the increase in osteoclast number or the loss of trabecular plates. Importantly, PTH treatment increased the retention of a baseline flurochrome label, osteoblast number, and bone formation in the proximal tibial metaphysis regardless of the level of mechanical usage. These findings demonstrate that programed administration of PTH is effective in increasing osteoblast number and bone formation and has beneficial effects on bone volume in the absence of weight-bearing and gonadal hormones. We conclude that the actions of PTH on cancellous bone are independent of the level of mechanical usage.
19 CFR 133.22 - Restrictions on importation of articles bearing copying or simulating trademarks.
Code of Federal Regulations, 2011 CFR
2011-04-01
... copying or simulating trademarks. 133.22 Section 133.22 Customs Duties U.S. CUSTOMS AND BORDER PROTECTION... Importations Bearing Registered and/or Recorded Trademarks or Recorded Trade Names § 133.22 Restrictions on... be denied entry and subject to detention as provided in § 133.25. (c) Relief from detention of...
NASA Technical Reports Server (NTRS)
Ma, Ki; Lamb, Mark; Chen, Peter; Wilson, Thomas; Cooley, Rodger; Xia, Harold; Fowler, Clay; Chen, Quark; Chu, Wei-Kan
1995-01-01
A bearing for telescope mounts on the moon has to function in a cold dusty vacuum environment that impairs the operation of almost all traditional bearings, but it is a natural environment for bearings constructed out of magnets and high temperature superconductors. The challenge lies not so much in the weight of the telescope that has to be supported, but in the smoothness of forces required for precision positioning control over a long stretch of time without human intervention. In this paper, we present a design of hybrid superconductor magnet bearings intended for use on the azimuth mount of an altitude-azimuth telescope mount system. In addition to the general features of hybrid super conducting magnet bearings, we will address particular issues connected with the application of these bearings on a telescope mount.
NASA Astrophysics Data System (ADS)
Weaver, John B.; Miller, Timothy B.; Perrinez, Philip R.; Doyley, Marvin M.; Wang, Huifang; Cheung, Yvonne Y.; Wrobel, James S.; Comi, Richard J.; Kennedy, Francis E.; Paulsen, Keith D.
2006-03-01
MR elastography (MRE) images the intrinsic mechanical properties of soft tissues; e.g., the shear modulus, μ. The μ of the plantar soft tissues is important in understanding the mechanisms whereby the forces induced during normal motion produce ulcers that lead to amputation in diabetic feet. We compared the compliance of the heel fat pad to compressive forces and to shearing forces. The design of prosthetics to protect the foot depends on the proper understanding of the mechanisms inducing damage. In the heel fat pads of six normal subjects, between 25 and 65 years of age, the μ for deformation perpendicular to the direction of weight bearing is similar but not identical to that determined for deformation along the weight bearing axis. The average difference between μ along the weight bearing axis and μ perpendicular to the weight bearing axis, is well correlated with age (Correlation Coefficient = 0.789). The p-value for the data being random was 0.0347 indicating that the observed difference is not likely to be random. The p-value for control points is 0.8989, indicating a random process. The results are suggestive that the high compressive forces imposed during walking damage the heel fat pads over time resulting in softening to compression preferentially over shearing. It is important to validate the observed effect with larger numbers of subjects, and better controls including measures of activity, and to understand if diseases like diabetes increase the observed damage.
Fadel, Mohamed; Ahmed, Mohamed Ali; Al-Dars, Ahmed Mounir; Maabed, Mustafa Ahmed; Shawki, Hashem
2015-03-01
The purpose of this study was to evaluate the outcome of Ilizarov external fixation (IE) versus dynamic compression plate (PO) in the management of extra-articular distal tibial fractures. Between 2010 and 2011, extra-articular distal tibial fractures in 40 consecutive patients met the inclusion criteria. They were classified according to AO classification fracture type A (A1, A2, and A3). In a randomized method, two equal groups were managed using either IE or PO. PO was performed using open reduction and internal fixation (ORIF) and DCP through anterolateral approach. IE was done using Ilizarov frame. For the PO group, non-weight bearing ambulation was permitted on the second postoperative day but partial weight bearing was permitted according to the progression in union criteria clinically and radiologically. For the IE group, weight bearing started as tolerated from the first postoperative day. Physiotherapy and pin-site care was performed by the patient themselves. Modified Mazur ankle score was applied to IE (excellent 10, good 10) and in PO (excellent 2, good 8, poor 6). Data were statically analysed using (Mann-Whitney test). The rate of healing in the IE group (average 130) was higher than the PO (average 196.5); plus, there were no cases of delayed union or nonunion in the IE group (p value 0.003). It was found that IE compared with PO provides provision of immediate weight bearing as tolerated following postoperative recovery, irrespective of radiological or clinical healing with no infection, deformity or non-union.
Relationship between asymmetry of quiet standing balance control and walking post-stroke.
Hendrickson, Janna; Patterson, Kara K; Inness, Elizabeth L; McIlroy, William E; Mansfield, Avril
2014-01-01
Spatial and temporal gait asymmetry is common after stroke. Such asymmetric gait is inefficient, can contribute to instability and may lead to musculoskeletal injury. However, understanding of the determinants of such gait asymmetry remains incomplete. The current study is focused on revealing if there is a link between asymmetry during the control of standing balance and asymmetry during walking. This study involved review of data from 94 individuals with stroke referred to a gait and balance clinic. Participants completed three tests: (1) walking at their usual pace; (2) quiet standing; and (3) standing with maximal loading of the paretic side. A pressure sensitive mat recorded placement and timing of each footfall during walking. Standing tests were completed on two force plates to evaluate symmetry of weight bearing and contribution of each limb to balance control. Multiple regression was conducted to determine the relationships between symmetry during standing and swing time, stance time, and step length symmetry during walking. Symmetry of antero-posterior balance control and weight bearing were related to swing time and step length symmetry during walking. Weight-bearing symmetry, weight-bearing capacity, and symmetry of antero-posterior balance control were related to stance time symmetry. These associations were independent of underlying lower limb impairment. The results support the hypothesis that impaired ability of the paretic limb to control balance may contribute to gait asymmetry post-stroke. Such work suggests that rehabilitation strategies that increase the contribution of the paretic limb to standing balance control may increase symmetry of walking post-stroke. Copyright © 2013 Elsevier B.V. All rights reserved.
NEEMO 18-20: Analog Testing for Mitigation of Communication Latency During Human Space Exploration
NASA Technical Reports Server (NTRS)
Chappell, Steven P.; Beaton, Kara H.; Miller, Matthew J.; Graff, Trevor G.; Abercromby, Andrew F. J.; Gernhardt, Michael L.; Halcon, Christopher
2016-01-01
NASA Extreme Environment Mission Operations (NEEMO) is an underwater spaceflight analog that allows a true mission-like operational environment and uses buoyancy effects and added weight to simulate different gravity levels. Three missions were undertaken from 2014-2015, NEEMO's 18-20. All missions were performed at the Aquarius undersea research habitat. During each mission, the effects of communication latencies on operations concepts, timelines, and tasks were studied. METHODS: Twelve subjects (4 per mission) were weighed out to simulate near-zero or partial gravity extravehicular activity (EVA) and evaluated different operations concepts for integration and management of a simulated Earth-based science team (ST) to provide input and direction during exploration activities. Exploration traverses were preplanned based on precursor data. Subjects completed science-related tasks including pre-sampling surveys, geologic-based sampling, and marine-based sampling as a portion of their tasks on saturation dives up to 4 hours in duration that were designed to simulate extravehicular activity (EVA) on Mars or the moons of Mars. One-way communication latencies, 5 and 10 minutes between space and mission control, were simulated throughout the missions. Objective data included task completion times, total EVA times, crew idle time, translation time, ST assimilation time (defined as time available for ST to discuss data/imagery after data acquisition). Subjective data included acceptability, simulation quality, capability assessment ratings, and comments. RESULTS: Precursor data can be used effectively to plan and execute exploration traverse EVAs (plans included detailed location of science sites, high-fidelity imagery of the sites, and directions to landmarks of interest within a site). Operations concepts that allow for pre-sampling surveys enable efficient traverse execution and meaningful Mission Control Center (MCC) interaction across communication latencies and can be done with minimal crew idle time. Imagery and contextual information from the EVA crew that is transmitted real-time to the intravehicular (IV) crewmember(s) can be used to verify that exploration traverse plans are being executed correctly. That same data can be effectively used by MCC (across comm latency) to provide meaningful feedback and instruction to the crew regarding sampling priorities, additional tasks, and changes to the EVA timeline. Text / data capabilities are preferred over voice capabilities between MCC and IV when executing exploration traverse plans over communication latency.
Vibration analysis of paper machine's asymmetric tube roll supported by spherical roller bearings
NASA Astrophysics Data System (ADS)
Heikkinen, Janne E.; Ghalamchi, Behnam; Viitala, Raine; Sopanen, Jussi; Juhanko, Jari; Mikkola, Aki; Kuosmanen, Petri
2018-05-01
This paper presents a simulation method that is used to study subcritical vibrations of a tube roll in a paper machine. This study employs asymmetric 3D beam elements based on the Timoshenko beam theory. An asymmetric beam model accounts for varying stiffness and mass distributions. Additionally, a detailed rolling element bearing model defines the excitations arising from the set of spherical roller bearings at both ends of the rotor. The results obtained from the simulation model are compared against the results from the measurements. The results indicate that the waviness of the bearing rolling surfaces contributes significantly to the subcritical vibrations while the asymmetric properties of the tube roll have only a fractional effect on the studied vibrations.
Effect of armor and carrying load on body balance and leg muscle function.
Park, Huiju; Branson, Donna; Kim, Seonyoung; Warren, Aric; Jacobson, Bert; Petrova, Adriana; Peksoz, Semra; Kamenidis, Panagiotis
2014-01-01
This study investigated the impact of weight and weight distribution of body armor and load carriage on static body balance and leg muscle function. A series of human performance tests were conducted with seven male, healthy, right-handed military students in seven garment conditions with varying weight and weight distributions. Static body balance was assessed by analyzing the trajectory of center of plantar pressure and symmetry of weight bearing in the feet. Leg muscle functions were assessed by analyzing the peak electromyography amplitude of four selected leg muscles during walking. Results of this study showed that uneven weight distribution of garment and load beyond an additional 9 kg impaired static body balance as evidenced by increased sway of center of plantar pressure and asymmetry of weight bearing in the feet. Added weight on non-dominant side of the body created greater impediment to static balance. Increased garment weight also elevated peak EMG amplitude in the rectus femoris to maintain body balance and in the medial gastrocnemius to increase propulsive force. Negative impacts on balance and leg muscle function with increased carrying loads, particularly with an uneven weight distribution, should be stressed to soldiers, designers, and sports enthusiasts. Copyright © 2013 Elsevier B.V. All rights reserved.
Color Filtering Localization for Three-Dimensional Underwater Acoustic Sensor Networks
Liu, Zhihua; Gao, Han; Wang, Wuling; Chang, Shuai; Chen, Jiaxing
2015-01-01
Accurate localization of mobile nodes has been an important and fundamental problem in underwater acoustic sensor networks (UASNs). The detection information returned from a mobile node is meaningful only if its location is known. In this paper, we propose two localization algorithms based on color filtering technology called PCFL and ACFL. PCFL and ACFL aim at collaboratively accomplishing accurate localization of underwater mobile nodes with minimum energy expenditure. They both adopt the overlapping signal region of task anchors which can communicate with the mobile node directly as the current sampling area. PCFL employs the projected distances between each of the task projections and the mobile node, while ACFL adopts the direct distance between each of the task anchors and the mobile node. The proportion factor of distance is also proposed to weight the RGB values. By comparing the nearness degrees of the RGB sequences between the samples and the mobile node, samples can be filtered out. The normalized nearness degrees are considered as the weighted standards to calculate the coordinates of the mobile nodes. The simulation results show that the proposed methods have excellent localization performance and can localize the mobile node in a timely way. The average localization error of PCFL is decreased by about 30.4% compared to the AFLA method. PMID:25774706
Wang, Chi-Hsu; Chen, Chun-Yao; Hung, Kun-Neng
2015-06-01
In this paper, a new adaptive self-organizing map (SOM) with recurrent neural network (RNN) controller is proposed for task assignment and path evolution of missile defense system (MDS). We address the problem of N agents (defending missiles) and D targets (incoming missiles) in MDS. A new RNN controller is designed to force an agent (or defending missile) toward a target (or incoming missile), and a monitoring controller is also designed to reduce the error between RNN controller and ideal controller. A new SOM with RNN controller is then designed to dispatch agents to their corresponding targets by minimizing total damaging cost. This is actually an important application of the multiagent system. The SOM with RNN controller is the main controller. After task assignment, the weighting factors of our new SOM with RNN controller are activated to dispatch the agents toward their corresponding targets. Using the Lyapunov constraints, the weighting factors for the proposed SOM with RNN controller are updated to guarantee the stability of the path evolution (or planning) system. Excellent simulations are obtained using this new approach for MDS, which show that our RNN has the lowest average miss distance among the several techniques.
Detection of faults in rotating machinery using periodic time-frequency sparsity
NASA Astrophysics Data System (ADS)
Ding, Yin; He, Wangpeng; Chen, Binqiang; Zi, Yanyang; Selesnick, Ivan W.
2016-11-01
This paper addresses the problem of extracting periodic oscillatory features in vibration signals for detecting faults in rotating machinery. To extract the feature, we propose an approach in the short-time Fourier transform (STFT) domain where the periodic oscillatory feature manifests itself as a relatively sparse grid. To estimate the sparse grid, we formulate an optimization problem using customized binary weights in the regularizer, where the weights are formulated to promote periodicity. In order to solve the proposed optimization problem, we develop an algorithm called augmented Lagrangian majorization-minimization algorithm, which combines the split augmented Lagrangian shrinkage algorithm (SALSA) with majorization-minimization (MM), and is guaranteed to converge for both convex and non-convex formulation. As examples, the proposed approach is applied to simulated data, and used as a tool for diagnosing faults in bearings and gearboxes for real data, and compared to some state-of-the-art methods. The results show that the proposed approach can effectively detect and extract the periodical oscillatory features.
[Distal femoral osteotomy using a lateral opening wedge technique].
Feucht, M J; Mehl, J; Forkel, P; Imhoff, A B; Hinterwimmer, S
2017-08-01
To shift the weight-bearing axis of the lower limb medially by opening a lateral-based metaphyseal osteotomy at the distal femur. Femoral-based valgus malalignment and symptomatic lateral unicompartimental osteoarthritis, lateral hyperpression syndrome, cartilage therapy of the lateral compartment, lateral meniscal replacement/transplantation, medial instability with valgus thrust, reconstruction of the medial collateral ligament, patellar instability and/or maltracking. Advanced cartilage damage (>grade 2) or subtotal meniscal loss of the medial compartment, age >65 years (relative), nicotine abuse, body mass index >30, flexion contracture >25°, corrections with a wedge base >10 mm in case of congenital deformities, inflammatory or septic arthritis, severe osteoporosis. Lateral approach to the distal femur; biplanar osteotomy (frontal + axial osteotomy), gradual opening of the osteotomy, osteotomy fixation with a locking plate. Free range of motion. Partial weight bearing with 20 kg for 2 weeks, followed by progressive weight bearing thereafter. Mean improvement of knee scores from 20-30 points and mean 10-year survival rate of 80% in patients with lateral unicompartimental osteoarthritis. Mean complication rate of 9%.
Locomotor Adaptation to an Asymmetric Force on the Human Pelvis Directed Along the Right Leg.
Vashista, Vineet; Martelli, Dario; Agrawal, Sunil
2015-09-11
In this work, we study locomotor adaptation in healthy adults when an asymmetric force vector is applied to the pelvis directed along the right leg. A cable-driven Active Tethered Pelvic Assist Device (A-TPAD) is used to apply an external force on the pelvis, specific to a subject's gait pattern. The force vector is intended to provide external weight bearing during walking and modify the durations of limb supports. The motivation is to use this paradigm to improve weight bearing and stance phase symmetry in individuals with hemiparesis. An experiment with nine healthy subjects was conducted. The results show significant changes in the gait kinematics and kinetics while the healthy subjects developed temporal and spatial asymmetry in gait pattern in response to the applied force vector. This was followed by aftereffects once the applied force vector was removed. The adaptation to the applied force resulted in asymmetry in stance phase timing and lower limb muscle activity. We believe this paradigm, when extended to individuals with hemiparesis, can show improvements in weight bearing capability with positive effects on gait symmetry and walking speed.
Women, work and pregnancy outcome.
Huffman, S
1988-01-01
In developing countries, 1/3 of infants are born weighing less than 2500 grams. A study conducted in Ethiopia among women consuming about 1600 kcal/day, those who were very physically active during pregnancy bore smaller babies, and gained less weight during pregnancy, than those who were not so active. Average birth weight was 3068 grams for the 1st group, 3270 grams for the less active. The active group of women gained an average of 6.5 kilograms, and the less active 9.2 kilograms. Women who did not engage in heavy work during pregnancy, although they were undernourished, apparently did not bear growth-retarded babies. Indirect evidence for the effect of physical activity on pregnancy outcome comes from studies conducted in Taiwan, and the Gambia. These studies, and others from Malawi, Burkina Faso, and Kenya have shown that women's energy expenditures vary greatly with the agricultural season. Daily housekeeping tasks, however, also consume a lot of women's energy. Technologies that allow women to reduce energy expenditure can have beneficial effects, if they do not simultaneously reduce their incomes. For instance, programs improving water or fuel availability, or reducing fuel needs, reduce women's energy expenditures. Food processing mills can help too if women have access to them, and are thus not in danger of being displaced from their jobs and losing necessary income. Examples of technology improving women's tasks are pedal drying machines for nice in Bangladesh, using a greater and pressing machine to prepare gari in Ghana; but growing thicker rice stalks in Indonesia displaced women workers and reduced income.
Cherry, S.; White, G.C.; Keating, K.A.; Haroldson, Mark A.; Schwartz, Charles C.
2007-01-01
Current management of the grizzly bear (Ursus arctos) population in Yellowstone National Park and surrounding areas requires annual estimation of the number of adult female bears with cubs-of-the-year. We examined the performance of nine estimators of population size via simulation. Data were simulated using two methods for different combinations of population size, sample size, and coefficient of variation of individual sighting probabilities. We show that the coefficient of variation does not, by itself, adequately describe the effects of capture heterogeneity, because two different distributions of capture probabilities can have the same coefficient of variation. All estimators produced biased estimates of population size with bias decreasing as effort increased. Based on the simulation results we recommend the Chao estimator for model M h be used to estimate the number of female bears with cubs of the year; however, the estimator of Chao and Shen may also be useful depending on the goals of the research.
NASA Technical Reports Server (NTRS)
Tipton, Charles M.
1991-01-01
The primary purpose of this research is to study the physiological mechanisms associated with the exercise performance of rats subjected to conditions of simulated weightlessness. A secondary purpose is to study related physiological changes associated with other systems. To facilitate these goals, a rodent suspension model was developed (Overton-Tipton) and a VO2 max testing procedure was perfected. Three methodological developments occurred during this past year deserving of mention. The first was the refinement of the tail suspension model so that (1) the heat dissipation functions of the caudal artery can be better utilized, and (2) the blood flow distribution to the tail would have less external constriction. The second was the development on a one-leg weight bearing model for use in simulated weightlessness studies concerned with change in muscle mass, muscle enzyme activity, and hind limb blood flow. The chemical body composition of 30 rats was determined and used to develop a prediction equation for percent fat using underwater weighing procedures to measure carcass specific gravity and to calculate body density, body fat, and fat free mass.
Reduction in bearing size due to superconductors in magnetic bearings
NASA Technical Reports Server (NTRS)
Rao, Dantam K.; Lewis, Paul; Dill, James F.
1991-01-01
A design concept that reduces the size of magnetic bearings is assessed. The small size will enable magnetic bearings to fit into limited available bearing volume of cryogenic machinery. The design concept, called SUPERC, uses (high Tc) superconductors or high-purity aluminum conductors in windings instead of copper. The relatively high-current density of these conductors reduces the slot radial thickness for windings, which reduces the size of the bearings. MTI developed a sizing program called SUPERC that translates the high-current density of these conductors into smaller sized bearings. This program was used to size a superconducting bearing to carry a 500 lb. load. The sizes of magnetic bearings needed by various design concepts are as follows: SUPERC design concept = 3.75 in.; magnet-bias design concept = 5.25 in.; and all electromagnet design concept = 7.0 in. These results indicate that the SUPERC design concept can significantly reduce the size of the bearing. This reduction, in turn, reduces the weight and yields a lighter bearing. Since the superconductors have inherently near-zero resistance, they are also expected to save power needed for operation considerably.
Tonouchi, Hidekazu; Sasayama, Akina
2018-01-01
Low-carbohydrate, high-fat diets (ketogenic diets) might prevent tumor progression and could be used as supportive therapy; however, few studies have addressed the effect of such diets on colorectal cancer. An infant formula with a ketogenic composition (ketogenic formula; KF) is used to treat patients with refractory epilepsy. We investigated the effect of KF on cancer and cancer cachexia in colon tumor-bearing mice. Mice were randomized into normal (NR), tumor-bearing (TB), and ketogenic formula (KF) groups. Colon 26 cells were inoculated subcutaneously into TB and KF mice. The NR and TB groups received a standard diet, and the KF mice received KF ad libitum. KF mice preserved their body, muscle, and carcass weights. Tumor weight and plasma IL-6 levels were significantly lower in KF mice than in TB mice. In the KF group, energy intake was significantly higher than that in the other two groups. Blood ketone body concentrations in KF mice were significantly elevated, and there was a significant negative correlation between blood ketone body concentration and tumor weight. Therefore, KF may suppress the progression of cancer and the accompanying systemic inflammation without adverse effects on weight gain, or muscle mass, which might help to prevent cancer cachexia. PMID:29443873
Bang, Yo-Soon; Son, Kyung Hyun; Kim, Hyun Jin
2016-11-01
[Purpose] The purpose of this study is to investigate the effects of virtual reality training using Nintendo Wii on balance and walking for stroke patients. [Subjects and Methods] Forty stroke patients with stroke were randomly divided into two exercise program groups: virtual reality training (n=20) and treadmill (n=20). The subjects underwent their 40-minute exercise program three times a week for eight weeks. Their balance and walking were measured before and after the complete program. We measured the left/right weight-bearing and the anterior/posterior weight-bearing for balance, as well as stance phase, swing phase, and cadence for walking. [Results] For balance, both groups showed significant differences in the left/right and anterior/posterior weight-bearing, with significant post-program differences between the groups. For walking, there were significant differences in the stance phase, swing phase, and cadence of the virtual reality training group. [Conclusion] The results of this study suggest that virtual reality training providing visual feedback may enable stroke patients to directly adjust their incorrect weight center and shift visually. Virtual reality training may be appropriate for patients who need improved balance and walking ability by inducing their interest for them to perform planned exercises on a consistent basis.
Bang, Yo-Soon; Son, Kyung Hyun; Kim, Hyun Jin
2016-01-01
[Purpose] The purpose of this study is to investigate the effects of virtual reality training using Nintendo Wii on balance and walking for stroke patients. [Subjects and Methods] Forty stroke patients with stroke were randomly divided into two exercise program groups: virtual reality training (n=20) and treadmill (n=20). The subjects underwent their 40-minute exercise program three times a week for eight weeks. Their balance and walking were measured before and after the complete program. We measured the left/right weight-bearing and the anterior/posterior weight-bearing for balance, as well as stance phase, swing phase, and cadence for walking. [Results] For balance, both groups showed significant differences in the left/right and anterior/posterior weight-bearing, with significant post-program differences between the groups. For walking, there were significant differences in the stance phase, swing phase, and cadence of the virtual reality training group. [Conclusion] The results of this study suggest that virtual reality training providing visual feedback may enable stroke patients to directly adjust their incorrect weight center and shift visually. Virtual reality training may be appropriate for patients who need improved balance and walking ability by inducing their interest for them to perform planned exercises on a consistent basis. PMID:27942130
Biot-Gassmann theory for velocities of gas hydrate-bearing sediments
Lee, M.W.
2002-01-01
Elevated elastic velocities are a distinct physical property of gas hydrate-bearing sediments. A number of velocity models and equations (e.g., pore-filling model, cementation model, effective medium theories, weighted equations, and time-average equations) have been used to describe this effect. In particular, the weighted equation and effective medium theory predict reasonably well the elastic properties of unconsolidated gas hydrate-bearing sediments. A weakness of the weighted equation is its use of the empirical relationship of the time-average equation as one element of the equation. One drawback of the effective medium theory is its prediction of unreasonably higher shear-wave velocity at high porosities, so that the predicted velocity ratio does not agree well with the observed velocity ratio. To overcome these weaknesses, a method is proposed, based on Biot-Gassmann theories and assuming the formation velocity ratio (shear to compressional velocity) of an unconsolidated sediment is related to the velocity ratio of the matrix material of the formation and its porosity. Using the Biot coefficient calculated from either the weighted equation or from the effective medium theory, the proposed method accurately predicts the elastic properties of unconsolidated sediments with or without gas hydrate concentration. This method was applied to the observed velocities at the Mallik 2L-39 well, Mackenzie Delta, Canada.
Dietz, R; Born, E W; Rigét, F; Aubail, A; Sonne, C; Drimmie, R; Basu, N
2011-02-15
Hair samples from 117 Northwest Greenland polar bears (Ursus maritimus) were taken during 1892-2008 and analyzed for total mercury (hereafter Hg). The sample represented 28 independent years and the aim of the study was to analyze for temporal Hg trends. Mercury concentrations showed yearly significant increases of 1.6-1.7% (p < 0.0001) from 1892 to 2008 and the two most recent median concentrations from 2006 and 2008 were 23- to 27-fold higher respectively than baseline level from 1300 A.D. in the same region (Nuullit). This indicates that the present (2006-2008) Northwest Greenland polar bear Hg exposure is 95.6-96.2% anthropogenic in its origin. Assuming a continued anthropogenic increase, this model estimated concentrations in 2050 and 2100 will be 40- and 92-fold the baseline concentration, respectively, which is equivalent to a 97.5 and 98.9% man-made contribution. None of the 2001-2008 concentrations of Hg in Northwest Greenland polar bear hair exceeded the general guideline values of 20-30 μg/g dry weight for terrestrial wildlife, whereas the neurochemical effect level of 5.4 μg Hg/g dry weight proposed for East Greenland polar bears was exceeded in 93.5% of the cases. These results call for detailed effect studies in main target organs such as brain, liver, kidney, and sexual organs in the Northwest Greenland polar bears.
Nelson, O. Lynne; Wood, Rachael M.; Häggström, Jens; Kvart, Clarence; Robbins, Charles T.
2017-01-01
Adiponectin is the most abundant plasma adipokine, and is well known for its role in energy homeostasis and cardiac protection. In humans with dilated cardiomyopathy, myocardial adiponectin protein expression is reduced compared to normal hearts and has been implicated in the pathology of cardiomyopathy. Serum adiponectin levels are often conflicting, with higher levels associated with poor survival in humans with congestive heart failure (CHF). We evaluated adiponectin serum concentrations and myocardial protein expression in dogs with naturally occurring myxomatous mitral valve disease and CHF. We compared the findings to active and hibernating brown bears as bears are adapted to endure an extreme period of low cardiac output during their annual hibernation. Bears exhibited largely the active high-molecular weight (HMW) versus the low-molecular weight isoforms of myocardial adiponectin (HMW:LMW = 6.3) during both the active period and hibernation, while healthy dogs exhibited a more balanced mix of isoforms. Dogs with CHF expressed predominately HMW isoforms of adiponectin (HMW:LMW = 12.5), appearing more similar to bears. In contrast to humans, serum adiponectin was significantly lower in dogs with CHF and lowest levels in the severest CHF class. In both dogs and bears, myocardial adiponectin was expressed independent of circulating adiponectin concentrations, suggesting a local regulatory mechanism within the heart. PMID:29056695
Veeraselvam, M.; Sridhar, R.; Perumal, P.; Jayathangaraj, M. G.
2014-01-01
The present study was conducted to define the physiological responses of captive sloth bears immobilized with ketamine hydrochloride and xylazine hydrochloride and to determine and compare the values of hematology and serum biochemical parameters between sexes. A total of 15 sloth bears were immobilized using combination of ketamine hydrochloride and xylazine hydrochloride drugs at the dose rate of 5.0 milligram (mg) per kg body weight and 2.0 mg per kg body weight, respectively. The use of combination of these drugs was found satisfactory for the chemical immobilization of captive sloth bears. There were no significant differences observed in induction time and recovery time and physiological parameters such as heart rate, respiratory rate, and rectal temperature between sexes. Health related parameters comprising hematological values like packed cell volume (PCV), hemoglobin (Hb), red blood cell count (RBC), erythrocyte indices, and so forth and biochemical values like total protein, blood urea nitrogen (BUN), creatinine, alkaline amino-transferase (ALT), aspartate amino-transferase (AST), and so forth were estimated in 11 (5 males and 6 females) apparently healthy bears. Comparison between sexes revealed significant difference in PCV (P < 0.05) and mean corpuscular hemoglobin concentration (MCHC) (P < 0.05). The study might help to evaluate health profiles of sloth bears for appropriate line treatment. PMID:24876990
Helicopter flight-control design using an H(2) method
NASA Technical Reports Server (NTRS)
Takahashi, Marc D.
1991-01-01
Rate-command and attitude-command flight-control designs for a UH-60 helicopter in hover are presented and were synthesized using an H(2) method. Using weight functions, this method allows the direct shaping of the singular values of the sensitivity, complementary sensitivity, and control input transfer-function matrices to give acceptable feedback properties. The designs were implemented on the Vertical Motion Simulator, and four low-speed hover tasks were used to evaluate the control system characteristics. The pilot comments from the accel-decel, bob-up, hovering turn, and side-step tasks indicated good decoupling and quick response characteristics. However, an underlying roll PIO tendency was found to exist away from the hover condition, which was caused by a flap regressing mode with insufficient damping.
Damping capacity of a sealed squeeze film bearing
NASA Technical Reports Server (NTRS)
Dede, M. M.; Dogan, M.; Holmes, R.
1984-01-01
The advantages of incorporating an open-ended or weakly-sealed squeeze-film bearing in a flexible support structure simulating an aero-engine assembly were examined. Attention is given to empirically modelling the hydrodynamics of the more usual tightly-sealed squeeze-film bearing, with a view to assessing its damping performance.
Supervisory control of mobile sensor networks: math formulation, simulation, and implementation.
Giordano, Vincenzo; Ballal, Prasanna; Lewis, Frank; Turchiano, Biagio; Zhang, Jing Bing
2006-08-01
This paper uses a novel discrete-event controller (DEC) for the coordination of cooperating heterogeneous wireless sensor networks (WSNs) containing both unattended ground sensors (UGSs) and mobile sensor robots. The DEC sequences the most suitable tasks for each agent and assigns sensor resources according to the current perception of the environment. A matrix formulation makes this DEC particularly useful for WSN, where missions change and sensor agents may be added or may fail. WSN have peculiarities that complicate their supervisory control. Therefore, this paper introduces several new tools for DEC design and operation, including methods for generating the required supervisory matrices based on mission planning, methods for modifying the matrices in the event of failed nodes, or nodes entering the network, and a novel dynamic priority assignment weighting approach for selecting the most appropriate and useful sensors for a given mission task. The resulting DEC represents a complete dynamical description of the WSN system, which allows a fast programming of deployable WSN, a computer simulation analysis, and an efficient implementation. The DEC is actually implemented on an experimental wireless-sensor-network prototyping system. Both simulation and experimental results are presented to show the effectiveness and versatility of the developed control architecture.
NASA Technical Reports Server (NTRS)
Kibler, K. S.; Mcdaniel, G. A.
1981-01-01
A digital local linearization technique was used to solve a system of stiff differential equations which simulate a magnetic bearing assembly. The results prove the technique to be accurate, stable, and efficient when compared to a general purpose variable order Adams method with a stiff option.
Geometric Mixing, Peristalsis, and the Geometric Phase of the Stomach.
Arrieta, Jorge; Cartwright, Julyan H E; Gouillart, Emmanuelle; Piro, Nicolas; Piro, Oreste; Tuval, Idan
2015-01-01
Mixing fluid in a container at low Reynolds number--in an inertialess environment--is not a trivial task. Reciprocating motions merely lead to cycles of mixing and unmixing, so continuous rotation, as used in many technological applications, would appear to be necessary. However, there is another solution: movement of the walls in a cyclical fashion to introduce a geometric phase. We show using journal-bearing flow as a model that such geometric mixing is a general tool for using deformable boundaries that return to the same position to mix fluid at low Reynolds number. We then simulate a biological example: we show that mixing in the stomach functions because of the "belly phase," peristaltic movement of the walls in a cyclical fashion introduces a geometric phase that avoids unmixing.
Geometric Mixing, Peristalsis, and the Geometric Phase of the Stomach
Arrieta, Jorge; Cartwright, Julyan H. E.; Gouillart, Emmanuelle; Piro, Nicolas; Piro, Oreste; Tuval, Idan
2015-01-01
Mixing fluid in a container at low Reynolds number— in an inertialess environment—is not a trivial task. Reciprocating motions merely lead to cycles of mixing and unmixing, so continuous rotation, as used in many technological applications, would appear to be necessary. However, there is another solution: movement of the walls in a cyclical fashion to introduce a geometric phase. We show using journal-bearing flow as a model that such geometric mixing is a general tool for using deformable boundaries that return to the same position to mix fluid at low Reynolds number. We then simulate a biological example: we show that mixing in the stomach functions because of the “belly phase,” peristaltic movement of the walls in a cyclical fashion introduces a geometric phase that avoids unmixing. PMID:26154384
Liljelind, Ingrid; Pettersson, Hans; Nilsson, Leif; Wahlström, Jens; Toomingas, Allan; Lundström, Ronnie; Burström, Lage
2013-10-01
There are numerous factors including physical, biomechanical, and individual that influence exposure to hand-transmitted vibration (HTV) and cause variability in the exposure measurements. Knowledge of exposure variability and determinants of exposure could be used to improve working conditions. We performed a quasi-experimental study, where operators performed routine work tasks in order to obtain estimates of the variance components and to evaluate the effect of determinants, such as machine-wheel combinations and individual operator characteristics. Two pre-defined simulated work tasks were performed by 11 operators: removal of a weld puddle of mild steel and cutting of a square steel pipe. In both tasks, four angle grinders were used, two running on compressed air and two electrically driven. Two brands of both grinding and cutting wheels were used. Each operator performed both tasks twice in a random order with each grinder and wheel and the time to complete each task was recorded. Vibration emission values were collected and the wheel wear was measured as loss of weight. Operators' characteristics collected were as follows: age, body height and weight, length and volume of their hands, maximum hand grip force, and length of work experience with grinding machines (years). The tasks were also performed by one operator who used four machines of the same brand. Mixed and random effects models were used in the statistical evaluation. The statistical evaluation was performed for grinding and cutting separately and we used a measure referring to the sum of the 1-s r.m.s. average frequency-weighted acceleration over time for completing the work task (a(sa)). Within each work task, there was a significant effect as a result of the determinants 'the machine used', 'wheel wear', and 'time taken to complete the task'. For cutting, 'the brand of wheel' used also had a significant effect. More than 90% of the inherent variability in the data was explained by the determinants. The two electrically powered machines had a mean a(sa) that was 2.6 times higher than the two air-driven machines. For cutting, the effect of the brand of wheel on a(sa) was ~0.1 times. The a(sa) increased both with increasing wheel wear and with time taken to complete the work task. However, there were also a number of interaction effects which, to a minor extent, modified the a(sa). Only a minor part (1%) of the total variability was attributed to the operator: for cutting, the volume of the hands, maximum grip force, and body weight were significant, while for grinding, it was the maximum grip force. There was no clear difference in a(sa) between the four copies of the same brand of each machine. By including determinants that were attributed to the brand of both machine and wheel used as well as the time taken to complete the work task, we were able to explain >90% of the variability. The dominating determinant was the brand of the machine. Little variability was found between operators, indicating that the overall effect as due to the operator was small.
Bernhardt, Kathie A; Beck, Lisa A; Lamb, Jeffry L; Kaufman, Kenton R; Amin, Shreyasee; Wuermser, Lisa-Ann
2012-04-01
The aim of the study was to determine the proportion of body weight borne through the lower limbs in persons with complete motor paraplegia using a standing frame, with and without the support of their arms. We also examined the effect of low-magnitude whole-body vibration on loads borne by the lower limbs. Vertical ground reaction forces (GRFs) were measured in 11 participants (six men and five women) with paraplegia of traumatic origin (injury level T3-T12) standing on a low-magnitude vibrating plate using a standing frame. GRFs were measured in four conditions: (1) no vibration with arms on standing frame tray, (2) no vibration with arms at side, (3) vibration with arms on tray, and (4) vibration with arms at side. GRF with arms on tray, without vibration, was 0.76 ± 0.07 body weight. With arms at the side, GRF increased to 0.85 ± 0.12 body weight. With vibration, mean GRF did not significantly differ from no-vibration conditions for either arm positions. Oscillation of GRF with vibration was significantly different from no-vibration conditions (P < 0.001) but similar in both arm positions. Men and women with paraplegia using a standing frame bear most of their weight through their lower limbs. Supporting their arms on the tray reduces the GRF by approximately 10% body weight. Low-magnitude vibration provided additional oscillation of the load-bearing forces and was proportionally similar regardless of arm position.
The role of uncertainty and reward on eye movements in a virtual driving task
Sullivan, Brian T.; Johnson, Leif; Rothkopf, Constantin A.; Ballard, Dana; Hayhoe, Mary
2012-01-01
Eye movements during natural tasks are well coordinated with ongoing task demands and many variables could influence gaze strategies. Sprague and Ballard (2003) proposed a gaze-scheduling model that uses a utility-weighted uncertainty metric to prioritize fixations on task-relevant objects and predicted that human gaze should be influenced by both reward structure and task-relevant uncertainties. To test this conjecture, we tracked the eye movements of participants in a simulated driving task where uncertainty and implicit reward (via task priority) were varied. Participants were instructed to simultaneously perform a Follow Task where they followed a lead car at a specific distance and a Speed Task where they drove at an exact speed. We varied implicit reward by instructing the participants to emphasize one task over the other and varied uncertainty in the Speed Task with the presence or absence of uniform noise added to the car's velocity. Subjects' gaze data were classified for the image content near fixation and segmented into looks. Gaze measures, including look proportion, duration and interlook interval, showed that drivers more closely monitor the speedometer if it had a high level of uncertainty, but only if it was also associated with high task priority or implicit reward. The interaction observed appears to be an example of a simple mechanism whereby the reduction of visual uncertainty is gated by behavioral relevance. This lends qualitative support for the primary variables controlling gaze allocation proposed in the Sprague and Ballard model. PMID:23262151
ERIC Educational Resources Information Center
Zembylas, Michalinos
2009-01-01
How can educators and their students interrogate the ethics and politics of suffering in ways that do not create fixed and totalized narratives from the past? In responding to this question, this essay draws on J. M. Coeetze's "Disgrace," and discusses how this novel constitutes a crucial site for bearing witness to the suffering…
NASA Technical Reports Server (NTRS)
Free, April M.; Flowers, George T.; Trent, Victor S.
1995-01-01
Auxiliary bearings are a critical feature of any magnetic bearing system. They protect the soft iron core of the magnetic bearing during an overload or failure. An auxiliary bearing typically consists of a rolling element bearing or bushing with a clearance gap between the rotor and the inner race of the support. The dynamics of such systems can be quite complex. It is desired to develop a rotordynamic model which describes the dynamic behavior of a flexible rotor system with magnetic bearings including auxiliary bearings. The model is based upon an experimental test facility. Some simulation studies are presented to illustrate the behavior of the model. In particular, the effects of introducing sideloading from the magnetic bearing when one coil fails is studied.