Sample records for simulating hpge detector

  1. Environmental radionuclides as contaminants of HPGe gamma-ray spectrometers: Monte Carlo simulations for Modane underground laboratory.

    PubMed

    Breier, R; Brudanin, V B; Loaiza, P; Piquemal, F; Povinec, P P; Rukhadze, E; Rukhadze, N; Štekl, I

    2018-05-21

    The main limitation in the high-sensitive HPGe gamma-ray spectrometry has been the detector background, even for detectors placed deep underground. Environmental radionuclides such as 40 K and decay products in the 238 U and 232 Th chains have been identified as the most important radioactive contaminants of construction parts of HPGe gamma-ray spectrometers. Monte Carlo simulations have shown that the massive inner and outer lead shields have been the main contributors to the HPGe-detector background, followed by aluminum cryostat, copper cold finger, detector holder and the lead ring with FET. The Monte Carlo simulated cosmic-ray background gamma-ray spectrum has been by about three orders of magnitude lower than the experimental spectrum measured in the Modane underground laboratory (4800 m w.e.), underlying the importance of using radiopure materials for the construction of ultra-low-level HPGe gamma-ray spectrometers. Copyright © 2018 Elsevier Ltd. All rights reserved.

  2. Monte Carlo simulation of the full energy peak efficiency of an HPGe detector.

    PubMed

    Khan, Waseem; Zhang, Qingmin; He, Chaohui; Saleh, Muhammad

    2018-01-01

    This paper presents a Monte Carlo method to obtain the full energy peak efficiency (FEPE) curve for a High Purity Germanium (HPGe) detector, as it is difficult and time-consuming to measure the FEPE curve experimentally. The Geant4 simulation toolkit was adopted to establish a detector model since detector specifications provided by the nominal manufacturer are usually insufficient to calculate the accurate efficiency of a detector. Several detector parameters were optimized. FEPE curves for a given HPGe detectors over the energy range of 59.50-1836keV were obtained and showed good agreements with those measured experimentally. FEPE dependences on detector parameters and source-detector distances were investigated. A best agreement with experimental result was achieved for a certain detector geometry and source-detector distance. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. New approach to calculate the true-coincidence effect of HpGe detector

    NASA Astrophysics Data System (ADS)

    Alnour, I. A.; Wagiran, H.; Ibrahim, N.; Hamzah, S.; Siong, W. B.; Elias, M. S.

    2016-01-01

    The corrections for true-coincidence effects in HpGe detector are important, especially at low source-to-detector distances. This work established an approach to calculate the true-coincidence effects experimentally for HpGe detectors of type Canberra GC3018 and Ortec GEM25-76-XLB-C, which are in operation at neutron activation analysis lab in Malaysian Nuclear Agency (NM). The correction for true-coincidence effects was performed close to detector at distances 2 and 5 cm using 57Co, 60Co, 133Ba and 137Cs as standard point sources. The correction factors were ranged between 0.93-1.10 at 2 cm and 0.97-1.00 at 5 cm for Canberra HpGe detector; whereas for Ortec HpGe detector ranged between 0.92-1.13 and 0.95-100 at 2 and 5 cm respectively. The change in efficiency calibration curve of the detector at 2 and 5 cm after correction was found to be less than 1%. Moreover, the polynomial parameters functions were simulated through a computer program, MATLAB in order to find an accurate fit to the experimental data points.

  4. Determination of efficiency of an aged HPGe detector for gaseous sources by self absorption correction and point source methods

    NASA Astrophysics Data System (ADS)

    Sarangapani, R.; Jose, M. T.; Srinivasan, T. K.; Venkatraman, B.

    2017-07-01

    Methods for the determination of efficiency of an aged high purity germanium (HPGe) detector for gaseous sources have been presented in the paper. X-ray radiography of the detector has been performed to get detector dimensions for computational purposes. The dead layer thickness of HPGe detector has been ascertained from experiments and Monte Carlo computations. Experimental work with standard point and liquid sources in several cylindrical geometries has been undertaken for obtaining energy dependant efficiency. Monte Carlo simulations have been performed for computing efficiencies for point, liquid and gaseous sources. Self absorption correction factors have been obtained using mathematical equations for volume sources and MCNP simulations. Self-absorption correction and point source methods have been used to estimate the efficiency for gaseous sources. The efficiencies determined from the present work have been used to estimate activity of cover gas sample of a fast reactor.

  5. Testing the Ge Detectors for the MAJORANA DEMONSTRATOR

    NASA Astrophysics Data System (ADS)

    Xu, W.; Abgrall, N.; Aguayo, E.; Avignone, F. T.; Barabash, A. S.; Bertrand, F. E.; Boswell, M.; Brudanin, V.; Busch, M.; Byram, D.; Caldwell, A. S.; Chan, Y.-D.; Christofferson, C. D.; Combs, D. C.; Cuesta, C.; Detwiler, J. A.; Doe, P. J.; Efremenko, Yu.; Egorov, V.; Ejiri, H.; Elliott, S. R.; Fast, J. E.; Finnerty, P.; Fraenkle, F. M.; Galindo-Uribarri, A.; Giovanetti, G. K.; Goett, J.; Green, M. P.; Gruszko, J.; Guiseppe, V. E.; Gusev, K.; Hallin, A. L.; Hazama, R.; Hegai, A.; Henning, R.; Hoppe, E. W.; Howard, S.; Howe, M. A.; Keeter, K. J.; Kidd, M. F.; Kochetov, O.; Konovalov, S. I.; Kouzes, R. T.; LaFerriere, B. D.; Leon, J.; Leviner, L. E.; Loach, J. C.; MacMullin, J.; MacMullin, S.; Martin, R. D.; Meijer, S.; Mertens, S.; Nomachi, M.; Orrell, J. L.; O'Shaughnessy, C.; Overman, N. R.; Phillips, D. G.; Poon, A. W. P.; Pushkin, K.; Radford, D. C.; Rager, J.; Rielage, K.; Robertson, R. G. H.; Romero-Romero, E.; Ronquest, M. C.; Schubert, A. G.; Shanks, B.; Shima, T.; Shirchenko, M.; Snavely, K. J.; Snyder, N.; Suriano, A. M.; Thompson, J.; Timkin, V.; Tornow, W.; Trimble, J. E.; Varner, R. L.; Vasilyev, S.; Vetter, K.; Vorren, K.; White, B. R.; Wilkerson, J. F.; Wiseman, C.; Yakushev, E.; Young, A. R.; Yu, C.-H.; Yumatov, V.

    High purity germanium (HPGe) crystals will be used for the MAJORANA DEMONSTRATOR, where they serve as both the source and the detector for neutrinoless double beta decay. It is crucial for the experiment to understand the performance of the HPGe crystals. A variety of crystal properties are being investigated, including basic properties such as energy resolution, efficiency, uniformity, capacitance, leakage current and crystal axis orientation, as well as more sophisticated properties, e.g. pulse shapes and dead layer and transition layer distributions. In this talk, we will present our measurements that characterize the HPGe crystals. We will also discuss the our simulation package for the detector characterization setup, and show that additional information can be extracted from data-simulation comparisons.

  6. Testing the Ge detectors for the MAJORANA DEMONSTRATOR

    DOE PAGES

    Xu, W.; Abgrall, N.; Aguayo, E.; ...

    2015-03-24

    High purity germanium (HPGe) crystals will be used for the Majorana Demonstrator, where they serve as both the source and the detector for neutrinoless double beta decay. It is crucial for the experiment to understand the performances of the HPGe crystals. A variety of crystal properties are being investigated, including both basic properties such as energy resolution, efficiency, uniformity, capacitance, leakage current and crystal axis orientation, as well as more sophisticated properties, e.g. pulse shapes and dead layer and transition layer distribution. In this talk, we will present our measurements that characterize the HPGe crystals. In addition, we will discussmore » the experiment’s simulation package for the detector characterization setup, where additional information is learned from data simulation comparisons.« less

  7. Performance revaluation of a N-type coaxial HPGe detector with front edges crystal using MCNPX.

    PubMed

    Azli, Tarek; Chaoui, Zine-El-Abidine

    2015-03-01

    The MCNPX code was used to determine the efficiency of a N-type HPGe detector after two decades of operation. Accounting for the roundedness of the crystal`s front edges and an inhomogeneous description of the detector's dead layers were shown to achieve better agreement between measurements and simulation efficiency determination. The calculations were experimentally verified using point sources in the energy range from 50keV to 1400keV, and an overall uncertainty less than 2% was achieved. In order to use the detector for different matrices and geometries in radioactivity, the suggested model was validated by changing the counting geometry and by using multi-gamma disc sources. The introduced simulation approach permitted the revaluation of the performance of an HPGe detector in comparison of its initial condition, which is a useful tool for precise determination of the thickness of the inhomogeneous dead layer. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. New approach to calculate the true-coincidence effect of HpGe detector

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Alnour, I. A., E-mail: aaibrahim3@live.utm.my, E-mail: ibrahim.elnour@yahoo.com; Wagiran, H.; Ibrahim, N.

    The corrections for true-coincidence effects in HpGe detector are important, especially at low source-to-detector distances. This work established an approach to calculate the true-coincidence effects experimentally for HpGe detectors of type Canberra GC3018 and Ortec GEM25-76-XLB-C, which are in operation at neutron activation analysis lab in Malaysian Nuclear Agency (NM). The correction for true-coincidence effects was performed close to detector at distances 2 and 5 cm using {sup 57}Co, {sup 60}Co, {sup 133}Ba and {sup 137}Cs as standard point sources. The correction factors were ranged between 0.93-1.10 at 2 cm and 0.97-1.00 at 5 cm for Canberra HpGe detector; whereas for Ortec HpGemore » detector ranged between 0.92-1.13 and 0.95-100 at 2 and 5 cm respectively. The change in efficiency calibration curve of the detector at 2 and 5 cm after correction was found to be less than 1%. Moreover, the polynomial parameters functions were simulated through a computer program, MATLAB in order to find an accurate fit to the experimental data points.« less

  9. SU-F-T-368: Improved HPGe Detector Precise Efficiency Calibration with Monte Carlo Simulations and Radioactive Sources

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhai, Y. John

    2016-06-15

    Purpose: To obtain an improved precise gamma efficiency calibration curve of HPGe (High Purity Germanium) detector with a new comprehensive approach. Methods: Both of radioactive sources and Monte Carlo simulation (CYLTRAN) are used to determine HPGe gamma efficiency for energy range of 0–8 MeV. The HPGe is a GMX coaxial 280 cm{sup 3} N-type 70% gamma detector. Using Momentum Achromat Recoil Spectrometer (MARS) at the K500 superconducting cyclotron of Texas A&M University, the radioactive nucleus {sup 24} Al was produced and separated. This nucleus has positron decays followed by gamma transitions up to 8 MeV from {sup 24} Mg excitedmore » states which is used to do HPGe efficiency calibration. Results: With {sup 24} Al gamma energy spectrum up to 8MeV, the efficiency for γ ray 7.07 MeV at 4.9 cm distance away from the radioactive source {sup 24} Al was obtained at a value of 0.194(4)%, by carefully considering various factors such as positron annihilation, peak summing effect, beta detector efficiency and internal conversion effect. The Monte Carlo simulation (CYLTRAN) gave a value of 0.189%, which was in agreement with the experimental measurements. Applying to different energy points, then a precise efficiency calibration curve of HPGe detector up to 7.07 MeV at 4.9 cm distance away from the source {sup 24} Al was obtained. Using the same data analysis procedure, the efficiency for the 7.07 MeV gamma ray at 15.1 cm from the source {sup 24} Al was obtained at a value of 0.0387(6)%. MC simulation got a similar value of 0.0395%. This discrepancy led us to assign an uncertainty of 3% to the efficiency at 15.1 cm up to 7.07 MeV. The MC calculations also reproduced the intensity of observed single-and double-escape peaks, providing that the effects of positron annihilation-in-flight were incorporated. Conclusion: The precision improved gamma efficiency calibration curve provides more accurate radiation detection and dose calculation for cancer radiotherapy treatment.« less

  10. MCNP HPGe detector benchmark with previously validated Cyltran model.

    PubMed

    Hau, I D; Russ, W R; Bronson, F

    2009-05-01

    An exact copy of the detector model generated for Cyltran was reproduced as an MCNP input file and the detection efficiency was calculated similarly with the methodology used in previous experimental measurements and simulation of a 280 cm(3) HPGe detector. Below 1000 keV the MCNP data correlated to the Cyltran results within 0.5% while above this energy the difference between MCNP and Cyltran increased to about 6% at 4800 keV, depending on the electron cut-off energy.

  11. Measured and simulated performance of Compton-suppressed TIGRESS HPGe clover detectors

    NASA Astrophysics Data System (ADS)

    Schumaker, M. A.; Hackman, G.; Pearson, C. J.; Svensson, C. E.; Andreoiu, C.; Andreyev, A.; Austin, R. A. E.; Ball, G. C.; Bandyopadhyay, D.; Boston, A. J.; Chakrawarthy, R. S.; Churchman, R.; Drake, T. E.; Finlay, P.; Garrett, P. E.; Grinyer, G. F.; Hyland, B.; Jones, B.; Maharaj, R.; Morton, A. C.; Phillips, A. A.; Sarazin, F.; Scraggs, H. C.; Smith, M. B.; Valiente-Dobón, J. J.; Waddington, J. C.; Watters, L. M.

    2007-01-01

    Tests of the performance of a 32-fold segmented HPGe clover detector coupled to a 20-fold segmented Compton-suppression shield, which form a prototype element of the TRIUMF-ISAC Gamma-Ray Escape-Suppressed Spectrometer (TIGRESS), have been made. Peak-to-total ratios and relative efficiencies have been measured for a variety of γ-ray energies. These measurements were used to validate a GEANT4 simulation of the TIGRESS detectors, which was then used to create a simulation of the full 12-detector array. Predictions of the expected performance of TIGRESS are presented. These predictions indicate that TIGRESS will be capable, for single 1 MeV γ rays, of absolute detection efficiencies of 17% and 9.4%, and peak-to-total ratios of 54% and 61% for the "high-efficiency" and "optimized peak-to-total" configurations of the array, respectively.

  12. Peak-to-valley ratios for three different HPGe detectors for the assessment of 137Cs deposition on the ground and the impact of the detector field-of-view.

    PubMed

    Östlund, Karl; Samuelsson, Christer; Mattsson, Sören; Rääf, Christopher L

    2017-02-01

    The peak-to-valley (PTV) method was investigated experimentally comparing PTV ratios for three HPGe detectors, with complementary Monte Carlo simulations of scatter in air for larger source-detector distances. The measured PTV ratios for 137Cs in air were similar for three different detectors for incident angles between 0 and 90°. The study indicated that the PTV method can differentiate between surface and shallow depth sources if the detector field of view is limited to a radius of less than 3.5m. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Computational characterization of HPGe detectors usable for a wide variety of source geometries by using Monte Carlo simulation and a multi-objective evolutionary algorithm

    NASA Astrophysics Data System (ADS)

    Guerra, J. G.; Rubiano, J. G.; Winter, G.; Guerra, A. G.; Alonso, H.; Arnedo, M. A.; Tejera, A.; Martel, P.; Bolivar, J. P.

    2017-06-01

    In this work, we have developed a computational methodology for characterizing HPGe detectors by implementing in parallel a multi-objective evolutionary algorithm, together with a Monte Carlo simulation code. The evolutionary algorithm is used for searching the geometrical parameters of a model of detector by minimizing the differences between the efficiencies calculated by Monte Carlo simulation and two reference sets of Full Energy Peak Efficiencies (FEPEs) corresponding to two given sample geometries, a beaker of small diameter laid over the detector window and a beaker of large capacity which wrap the detector. This methodology is a generalization of a previously published work, which was limited to beakers placed over the window of the detector with a diameter equal or smaller than the crystal diameter, so that the crystal mount cap (which surround the lateral surface of the crystal), was not considered in the detector model. The generalization has been accomplished not only by including such a mount cap in the model, but also using multi-objective optimization instead of mono-objective, with the aim of building a model sufficiently accurate for a wider variety of beakers commonly used for the measurement of environmental samples by gamma spectrometry, like for instance, Marinellis, Petris, or any other beaker with a diameter larger than the crystal diameter, for which part of the detected radiation have to pass through the mount cap. The proposed methodology has been applied to an HPGe XtRa detector, providing a model of detector which has been successfully verificated for different source-detector geometries and materials and experimentally validated using CRMs.

  14. The effects of Doppler broadening and detector resolution on the performance of three-stage Compton cameras

    PubMed Central

    Mackin, Dennis; Polf, Jerimy; Peterson, Steve; Beddar, Sam

    2013-01-01

    Purpose: The authors investigated how the characteristics of the detectors used in a three-stage Compton camera (CC) affect the CC's ability to accurately measure the emission distribution and energy spectrum of prompt gammas (PG) emitted by nuclear de-excitations during proton therapy. The detector characteristics they studied included the material (high-purity germanium [HPGe] and cadmium zinc telluride [CZT]), Doppler broadening (DB), and resolution (lateral, depth, and energy). Methods: The authors simulated three-stage HPGe and CZT CCs of various configurations, detecting gammas from point sources with energies ranging from 0.511 to 7.12 MeV. They also simulated a proton pencil beam irradiating a tissue target to study how the detector characteristics affect the PG data measured by CCs in a clinical proton therapy setting. They used three figures of merit: the distance of closest approach (DCA) and the point of closest approach (PCA) between the measured and actual position of the PG emission origin, and the calculated energy resolution. Results: For CCs with HPGe detectors, DB caused the DCA to be greater than 3 mm for 14% of the 6.13 MeV gammas and 20% of the 0.511 MeV gammas. For CCs with CZT detectors, DB caused the DCA to be greater than 3 mm for 18% of the 6.13 MeV gammas and 25% of the 0.511 MeV gammas. The full width at half maximum (FWHM) of the PCA in the \\documentclass[12pt]{minimal} \\usepackage{amsmath} \\usepackage{wasysym} \\usepackage{amsfonts} \\usepackage{amssymb} \\usepackage{amsbsy} \\usepackage{upgreek} \\usepackage{mathrsfs} \\setlength{\\oddsidemargin}{-69pt} \\begin{document} \\begin{equation*}\\hat z\\end{equation*} \\end{document}z^ direction for HPGe and CZT detectors ranged from 1.3 to 0.4 mm for gammas with incident energy ranging from 0.511 to 7.12 MeV. For CCs composed of HPGe detectors, the resolution of incident gamma energy calculated by the CC ranged from 6% to 1% for gammas with true incident energies from 0.511 to 7.12 MeV. For CCs composed of CZT detectors, the resolution of gamma energy calculated by the CC ranged from 10% to 1% for gammas with true incident energies from 0.511 to 7.12 MeV. For HPGe and CZT CCs in which all detector effect were included, the DCA was less than 3 mm for 75% and 68% of the detected gammas, respectively, and restricting gammas to those having energy greater than 2.0 MeV increased these percentages to 83% and 77% for HPGe and CZT, respectively. Distributions of the true gamma origins and the PCA after detector characteristics had been included showed good agreement on beam range and some loss of resolution for the lateral profile of the PG emission. Characteristic energy lines were evident in the calculated gamma energy spectrum. Conclusions: The authors found the following: (1) DB is the dominant source of spatial and energy resolution loss in the CCs at all energy levels; (2) the largest difference in the spatial resolution of HPGe and CZT CCs is that the spatial resolution distributions of CZT have broader tails. The differences in the FWHM of these distributions are small; (3) the energy resolution of both HPGe and CZT three-stage CCs is adequate for PG spectroscopy; and (4) restricting the gammas to those having energy greater than 2.0 MeV can improve the achievable image resolution. PMID:23298111

  15. The feasibility of well-logging measurements of arsenic levels using neutron-activation analysis

    USGS Publications Warehouse

    Oden, C.P.; Schweitzer, J.S.; McDowell, G.M.

    2006-01-01

    Arsenic is an extremely toxic metal, which poses a significant problem in many mining environments. Arsenic contamination is also a major problem in ground and surface waters. A feasibility study was conducted to determine if neutron-activation analysis is a practical method of measuring in situ arsenic levels. The response of hypothetical well-logging tools to arsenic was simulated using a readily available Monte Carlo simulation code (MCNP). Simulations were made for probes with both hyperpure germanium (HPGe) and bismuth germanate (BGO) detectors using accelerator and isotopic neutron sources. Both sources produce similar results; however, the BGO detector is much more susceptible to spectral interference than the HPGe detector. Spectral interference from copper can preclude low-level arsenic measurements when using the BGO detector. Results show that a borehole probe could be built that would measure arsenic concentrations of 100 ppm by weight to an uncertainty of 50 ppm in about 15 min. ?? 2006 Elsevier Ltd. All rights reserved.

  16. Monte Carlo simulation of gamma-ray interactions in an over-square high-purity germanium detector for in-vivo measurements

    NASA Astrophysics Data System (ADS)

    Saizu, Mirela Angela

    2016-09-01

    The developments of high-purity germanium detectors match very well the requirements of the in-vivo human body measurements regarding the gamma energy ranges of the radionuclides intended to be measured, the shape of the extended radioactive sources, and the measurement geometries. The Whole Body Counter (WBC) from IFIN-HH is based on an “over-square” high-purity germanium detector (HPGe) to perform accurate measurements of the incorporated radionuclides emitting X and gamma rays in the energy range of 10 keV-1500 keV, under conditions of good shielding, suitable collimation, and calibration. As an alternative to the experimental efficiency calibration method consisting of using reference calibration sources with gamma energy lines that cover all the considered energy range, it is proposed to use the Monte Carlo method for the efficiency calibration of the WBC using the radiation transport code MCNP5. The HPGe detector was modelled and the gamma energy lines of 241Am, 57Co, 133Ba, 137Cs, 60Co, and 152Eu were simulated in order to obtain the virtual efficiency calibration curve of the WBC. The Monte Carlo method was validated by comparing the simulated results with the experimental measurements using point-like sources. For their optimum matching, the impact of the variation of the front dead layer thickness and of the detector photon absorbing layers materials on the HPGe detector efficiency was studied, and the detector’s model was refined. In order to perform the WBC efficiency calibration for realistic people monitoring, more numerical calculations were generated simulating extended sources of specific shape according to the standard man characteristics.

  17. Calculation of Coincidence Summing Correction Factors for an HPGe detector using GEANT4.

    PubMed

    Giubrone, G; Ortiz, J; Gallardo, S; Martorell, S; Bas, M C

    2016-07-01

    The aim of this paper was to calculate the True Coincidence Summing Correction Factors (TSCFs) for an HPGe coaxial detector in order to correct the summing effect as a result of the presence of (88)Y and (60)Co in a multigamma source used to obtain a calibration efficiency curve. Results were obtained for three volumetric sources using the Monte Carlo toolkit, GEANT4. The first part of this paper deals with modeling the detector in order to obtain a simulated full energy peak efficiency curve. A quantitative comparison between the measured and simulated values was made across the entire energy range under study. The True Summing Correction Factors were calculated for (88)Y and (60)Co using the full peak efficiencies obtained with GEANT4. This methodology was subsequently applied to (134)Cs, and presented a complex decay scheme. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Development of CANDLES low background HPGe detector and half-life measurement of 180Tam

    NASA Astrophysics Data System (ADS)

    Chan, W. M.; Kishimoto, T.; Umehara, S.; Matsuoka, K.; Suzuki, K.; Yoshida, S.; Nakajima, K.; Iida, T.; Fushimi, K.; Nomachi, M.; Ogawa, I.; Tamagawa, Y.; Hazama, R.; Takemoto, Y.; Nakatani, N.; Takihira, Y.; Tozawa, M.; Kakubata, H.; Trang, V. T. T.; Ohata, T.; Tetsuno, K.; Maeda, T.; Khai, B. T.; Li, X. L.; Batpurev, T.

    2018-01-01

    A low background HPGe detector system was developed at CANDLES Experimental Hall for multipurpose use. Various low background techniques were employed, including hermatic shield design, radon gas suppression, and background reduction analysis. A new pulse shape discrimination (PSD) method was specially created for coaxial Ge detector. Using this PSD method, microphonics noise and background event at low energy region less than 200 keV can be rejected effectively. Monte Carlo simulation by GEANT4 was performed to acquire the detection efficiency and study the interaction of gamma-rays with detector system. For rare decay measurement, the detector was utilized to detect the nature's most stable isomer tantalum-180m (180Tam) decay. Two phases of tantalum physics run were completed with total livetime of 358.2 days, which Phase II has upgraded shield configuration. The world most stringent half-life limit of 180Tam has been successfully achieved.

  19. Germanium detectors in homeland security at PNNL

    DOE PAGES

    Stave, S.

    2015-05-01

    Neutron and gamma-ray detection is used for non-proliferation and national security applications. While lower energy resolution detectors such as NaI(Tl) have their place, high purity germanium (HPGe) also has a role to play. A detection with HPGe is often a characterization due to the very high energy resolution. However, HPGe crystals remain small and expensive leaving arrays of smaller crystals as an excellent solution. PNNL has developed two similar HPGe arrays for two very different applications. One array, the Multisensor Aerial Radiation Survey (MARS) detector is a fieldable array that has been tested on trucks, boats, and helicopters. The CASCADESmore » HPGe array is an array designed to assay samples in a low background environment. The history of HPGe arrays at PNNL and the development of MARS and CASCADES will be detailed in this paper along with some of the other applications of HPGe at PNNL.« less

  20. Optimization of Compton-suppression and summing schemes for the TIGRESS HPGe detector array

    NASA Astrophysics Data System (ADS)

    Schumaker, M. A.; Svensson, C. E.; Andreoiu, C.; Andreyev, A.; Austin, R. A. E.; Ball, G. C.; Bandyopadhyay, D.; Boston, A. J.; Chakrawarthy, R. S.; Churchman, R.; Drake, T. E.; Finlay, P.; Garrett, P. E.; Grinyer, G. F.; Hackman, G.; Hyland, B.; Jones, B.; Maharaj, R.; Morton, A. C.; Pearson, C. J.; Phillips, A. A.; Sarazin, F.; Scraggs, H. C.; Smith, M. B.; Valiente-Dobón, J. J.; Waddington, J. C.; Watters, L. M.

    2007-04-01

    Methods of optimizing the performance of an array of Compton-suppressed, segmented HPGe clover detectors have been developed which rely on the physical position sensitivity of both the HPGe crystals and the Compton-suppression shields. These relatively simple analysis procedures promise to improve the precision of experiments with the TRIUMF-ISAC Gamma-Ray Escape-Suppressed Spectrometer (TIGRESS). Suppression schemes will improve the efficiency and peak-to-total ratio of TIGRESS for high γ-ray multiplicity events by taking advantage of the 20-fold segmentation of the Compton-suppression shields, while the use of different summing schemes will improve results for a wide range of experimental conditions. The benefits of these methods are compared for many γ-ray energies and multiplicities using a GEANT4 simulation, and the optimal physical configuration of the TIGRESS array under each set of conditions is determined.

  1. Detection system for high-resolution gamma radiation spectroscopy with neutron time-of-flight filtering

    DOEpatents

    Dioszegi, Istvan; Salwen, Cynthia; Vanier, Peter

    2014-12-30

    A .gamma.-radiation detection system that includes at least one semiconductor detector such as HPGe-Detector, a position-sensitive .alpha.-Detector, a TOF Controller, and a Digitizer/Integrator. The Digitizer/Integrator starts to process the energy signals of a .gamma.-radiation sent from the HPGe-Detector instantly when the HPGe-Detector detects the .gamma.-radiation. Subsequently, it is determined whether a coincidence exists between the .alpha.-particles and .gamma.-radiation signal, based on a determination of the time-of-flight of neutrons obtained from the .alpha.-Detector and the HPGe-Detector. If it is determined that the time-of-flight falls within a predetermined coincidence window, the Digitizer/Integrator is allowed to continue and complete the energy signal processing. If, however, there is no coincidence, the Digitizer/Integrator is instructed to be clear and reset its operation instantly.

  2. Gamma-gamma coincidence performance of LaBr 3:Ce scintillation detectors vs HPGe detectors in high count-rate scenarios

    DOE PAGES

    Drescher, A.; Yoho, M.; Landsberger, S.; ...

    2017-01-15

    In this study, a radiation detection system consisting of two cerium doped lanthanum bromide (LaBr 3:Ce) scintillation detectors in a gamma-gamma coincidence configuration has been used to demonstrate the advantages that coincident detection provides relative to a single detector, and the advantages that LaBr 3:Ce detectors provide relative to high purity germanium (HPGe) detectors. Signal to noise ratios of select photopeak pairs for these detectors have been compared to high-purity germanium (HPGe) detectors in both single and coincident detector configurations in order to quantify the performance of each detector configuration. The efficiency and energy resolution of LaBr 3:Ce detectors havemore » been determined and compared to HPGe detectors. Coincident gamma-ray pairs from the radionuclides 152Eu and 133Ba have been identified in a sample that is dominated by 137Cs. Gamma-gamma coincidence successfully reduced the Compton continuum from the large 137Cs peak, revealed several coincident gamma energies characteristic of these nuclides, and improved the signal-to-noise ratio relative to single detector measurements. LaBr 3:Ce detectors performed at count rates multiple times higher than can be achieved with HPGe detectors. The standard background spectrum consisting of peaks associated with transitions within the LaBr 3:Ce crystal has also been significantly reduced. Finally, it is shown that LaBr 3:Ce detectors have the unique capability to perform gamma-gamma coincidence measurements in very high count rate scenarios, which can potentially benefit nuclear safeguards in situ measurements of spent nuclear fuel.« less

  3. Gamma-gamma coincidence performance of LaBr 3:Ce scintillation detectors vs HPGe detectors in high count-rate scenarios

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Drescher, A.; Yoho, M.; Landsberger, S.

    In this study, a radiation detection system consisting of two cerium doped lanthanum bromide (LaBr 3:Ce) scintillation detectors in a gamma-gamma coincidence configuration has been used to demonstrate the advantages that coincident detection provides relative to a single detector, and the advantages that LaBr 3:Ce detectors provide relative to high purity germanium (HPGe) detectors. Signal to noise ratios of select photopeak pairs for these detectors have been compared to high-purity germanium (HPGe) detectors in both single and coincident detector configurations in order to quantify the performance of each detector configuration. The efficiency and energy resolution of LaBr 3:Ce detectors havemore » been determined and compared to HPGe detectors. Coincident gamma-ray pairs from the radionuclides 152Eu and 133Ba have been identified in a sample that is dominated by 137Cs. Gamma-gamma coincidence successfully reduced the Compton continuum from the large 137Cs peak, revealed several coincident gamma energies characteristic of these nuclides, and improved the signal-to-noise ratio relative to single detector measurements. LaBr 3:Ce detectors performed at count rates multiple times higher than can be achieved with HPGe detectors. The standard background spectrum consisting of peaks associated with transitions within the LaBr 3:Ce crystal has also been significantly reduced. Finally, it is shown that LaBr 3:Ce detectors have the unique capability to perform gamma-gamma coincidence measurements in very high count rate scenarios, which can potentially benefit nuclear safeguards in situ measurements of spent nuclear fuel.« less

  4. Study of Compton suppression for use in spent nuclear fuel assay

    NASA Astrophysics Data System (ADS)

    Bender, Sarah

    The focus of this study has been to assess Compton suppressed gamma-ray detection systems for the multivariate analysis of spent nuclear fuel. This objective has been achieved using direct measurement of samples of irradiated fuel elements in two geometrical configurations with Compton suppression systems. In order to address the objective to quantify the number of additionally resolvable photopeaks, direct Compton suppressed spectroscopic measurements of spent nuclear fuel in two configurations were performed: as intact fuel elements and as dissolved feed solutions. These measurements directly assessed and quantified the differences in measured gamma-ray spectrum from the application of Compton suppression. Several irradiated fuel elements of varying cooling time from the Penn State Breazeale Reactor spent fuel inventory were measured using three Compton suppression systems that utilized different primary detectors: HPGe, LaBr3, and NaI(Tl). The application of Compton suppression using a LaBr3 primary detector to the measurement of the current core fuel element, which presented the highest count rate, allowed four additional spectral features to be resolved. In comparison, the HPGe-CSS was able to resolve eight additional photopeaks as compared to the standalone HPGe measurement. Measurements with the NaI(Tl) primary detector were unable to resolve any additional peaks, due to its relatively low resolution. Samples of Approved Test Material (ATM) commercial fuel elements were obtained from Pacific Northwest National Laboratory. The samples had been processed using the beginning stages of the PUREX method and represented the unseparated feed solution from a reprocessing facility. Compton suppressed measurements of the ATM fuel samples were recorded inside the guard detector annulus, to simulate the siphoning of small quantities from the main process stream for long dwell measurement periods. Photopeak losses were observed in the measurements of the dissolved ATM fuel samples because the spectra was recorded from the source in very close proximity to the detector and surrounded by the guard annulus, so the detection probability is very high. Though this configuration is optimal for a Compton suppression system for the measurement of low count rate samples, measurement of high count rate samples in the enclosed arrangement leads to sum peaks in both the suppressed and unsuppressed spectra and losses to photopeak counts in the suppressed spectra. No additional photopeaks were detected using Compton suppression with this geometry. A detector model was constructed that can accurately simulate a Compton suppressed spectral measurement of radiation from spent nuclear fuel using HPGe or LaBr3 detectors. This is the first detector model capable of such an accomplishment. The model uses the Geant4 toolkit coupled with the RadSrc application and it accepts spent fuel composition data in list form. The model has been validated using dissolved ATM fuel samples in the standard, enclosed geometry of the PSU HPGe-CSS. The model showed generally good agreement with both the unsuppressed and suppressed measured fuel sample spectra, however the simulation is more appropriate for the generation of gamma-ray spectra in the beam source configuration. Photopeak losses due to cascade decay emissions in the Compton suppressed spectra were not appropriately managed by the simulation. Compton suppression would be a beneficial addition to NDA process monitoring systems if oriented such that the gamma-ray photons are collimated to impinge the primary detector face as a beam. The analysis has shown that peak losses through accidental coincidences are minimal and the reduction in the Compton continuum allows additional peaks to be resolved. (Abstract shortened by UMI.).

  5. The study of in vivo quantification of aluminum (Al) in human bone with a compact DD generator-based neutron activation analysis (NAA) system.

    PubMed

    Byrne, Patrick; Mostafaei, Farshad; Liu, Yingzi; Blake, Scott P; Koltick, David; Nie, Linda H

    2016-05-01

    The feasibility and methodology of using a compact DD generator-based neutron activation analysis system to measure aluminum in hand bone has been investigated. Monte Carlo simulations were used to simulate the moderator, reflector, and shielding assembly and to estimate the radiation dose. A high purity germanium (HPGe) detector was used to detect the Al gamma ray signals. The minimum detectable limit (MDL) was found to be 11.13 μg g(-1) dry bone (ppm). An additional HPGe detector would improve the MDL by a factor of 1.4, to 7.9 ppm. The equivalent dose delivered to the irradiated hand was calculated by Monte Carlo to be 11.9 mSv. In vivo bone aluminum measurement with the DD generator was found to be feasible among general population with an acceptable dose to the subject.

  6. Assessment of uncertainties in the lung activity measurement of low-energy photon emitters using Monte Carlo simulation of ICRP male thorax voxel phantom.

    PubMed

    Nadar, M Y; Akar, D K; Rao, D D; Kulkarni, M S; Pradeepkumar, K S

    2015-12-01

    Assessment of intake due to long-lived actinides by inhalation pathway is carried out by lung monitoring of the radiation workers inside totally shielded steel room using sensitive detection systems such as Phoswich and an array of HPGe detectors. In this paper, uncertainties in the lung activity estimation due to positional errors, chest wall thickness (CWT) and detector background variation are evaluated. First, calibration factors (CFs) of Phoswich and an array of three HPGe detectors are estimated by incorporating ICRP male thorax voxel phantom and detectors in Monte Carlo code 'FLUKA'. CFs are estimated for the uniform source distribution in lungs of the phantom for various photon energies. The variation in the CFs for positional errors of ±0.5, 1 and 1.5 cm in horizontal and vertical direction along the chest are studied. The positional errors are also evaluated by resizing the voxel phantom. Combined uncertainties are estimated at different energies using the uncertainties due to CWT, detector positioning, detector background variation of an uncontaminated adult person and counting statistics in the form of scattering factors (SFs). SFs are found to decrease with increase in energy. With HPGe array, highest SF of 1.84 is found at 18 keV. It reduces to 1.36 at 238 keV. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  7. Positron annihilation spectroscopy techniques applied to the study of an HPGe detector

    NASA Astrophysics Data System (ADS)

    Nascimento, E. do; Vanin, V. R.; Maidana, N. L.; Silva, T. F.; Rizzutto, M. A.; Fernández-Varea, J. M.

    2013-05-01

    Doppler Broadening Spectroscopy of the large Ge crystal of an HPGe detector was performed using positrons from pair production of 6.13 MeV γ-rays from the 19F(p,αγ)16O reaction. Two HPGe detectors facing opposite sides of the Ge crystal acting as target provided both coincidence and singles spectra. Changes in the shape of the annihilation peak were observed when the high voltage applied to the target detector was switched on or off, amounting to somewhat less than 20% when the areas of equivalent energy intervals in the corresponding normalized spectra are compared.

  8. On the accuracy of gamma spectrometric isotope ratio measurements of uranium

    NASA Astrophysics Data System (ADS)

    Ramebäck, H.; Lagerkvist, P.; Holmgren, S.; Jonsson, S.; Sandström, B.; Tovedal, A.; Vesterlund, A.; Vidmar, T.; Kastlander, J.

    2016-04-01

    The isotopic composition of uranium was measured using high resolution gamma spectrometry. Two acid solutions and two samples in the form of UO2 pellets were measured. The measurements were done in close geometries, i.e. directly on the endcap of the high purity germanium detector (HPGe). Applying no corrections for count losses due to true coincidence summing (TCS) resulted in up to about 40% deviation in the abundance of 235U from the results obtained with mass spectrometry. However, after correction for TCS, excellent agreement was achieved between the results obtained using two different measurement methods, or a certified value. Moreover, after corrections, the fitted relative response curves correlated excellently with simulated responses, for the different geometries, of the HPGe detector.

  9. Simulated characteristics of the DEGAS γ-detector array

    NASA Astrophysics Data System (ADS)

    Li, G. S.; Lizarazo, C.; Gerl, J.; Kojouharov, I.; Schaffner, H.; Górska, M.; Pietralla, N.; Saha, S.; Liu, M. L.; Wang, J. G.

    2018-05-01

    The performance of the novel HPGe-Cluster array DEGAS to be used at FAIR has been studied through GEANT4 simulations using accurate geometries of most of the detector components. The simulation framework has been tested by comparing experimental data of various detector setups. The study showed that the DEGAS system could provide a clear improvement of the photo-peak efficiency compared to the previous RISING array. In addition, the active BGO Back-catcher could greatly enhance the background suppression capability. The add-back analysis revealed that even at a γ multiplicity of six the sensitivity is improved by adding back the energy depositions of the neighboring Ge crystals.

  10. Dependence of energy resolution of a plane-parallel HPGe detector on bias voltage upon registration of low-energy X-rays

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Samedov, V. V., E-mail: v-samedov@yandex.ru

    2016-12-15

    In this study, we theoretically analyze the processes in a plane-parallel high-purity germanium (HPGe) detector. The generating function of factorial moments describing the process of registration of low-energy X-rays by the HPGe detector with consideration of capture of charge carriers by traps is obtained. It is demonstrated that the coefficients of expansion of the average signal amplitude and variance in power series over the quantity inversely proportional to the bias voltage of the detector allow one to determine the Fano factor, the product of the charge carrier lifetime and mobility, and other characteristics of the semiconductor material of the detector.

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stave, Sean C.

    Neutron and gamma-ray detection is used for non-proliferation and national security applications. While lower energy resolution detectors such as NaI(Tl) have their place, high purity germanium (HPGe) also has a role to play. A detection with HPGe is often a characterization due to the very high energy resolution. However, HPGe crystals remain small and expensive leaving arrays of smaller crystals as an excellent solution. PNNL has developed two similar HPGe arrays for two very different applications. One array, the Multisensor Aerial Radiation Survey (MARS) detector is a fieldable array that has been tested on trucks, boats, and helicopters. The CASCADESmore » HPGe array is an array designed to assay samples in a low background environment. The history of HPGe arrays at PNNL and the development of MARS and CASCADES will be detailed in this paper along with some of the other applications of HPGe at PNNL.« less

  12. Theoretical consideration of the energy resolution in planar HPGe detectors for low energy X-rays

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Samedov, Victor V.

    In this work, theoretical consideration of the processes in planar High Purity Ge (HPGe) detectors for low energy X-rays using the random stochastic processes formalism was carried out. Using the random stochastic processes formalism, the generating function of the processes of X-rays registration in a planar HPGe detector was derived. The power serial expansions of the detector amplitude and the variance in terms of the inverse bias voltage were derived. The coefficients of these expansions allow determining the Fano factor, electron mobility lifetime product, nonuniformity of the trap density, and other characteristics of the semiconductor material. (authors)

  13. Germanium detectors for nuclear spectroscopy: Current research and development activity at LNL

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Napoli, D. R., E-mail: daniel.r.napoli@lnl.infn.it; Maggioni, G., E-mail: maggioni@lnl.infn.it; Carturan, S.

    2016-07-07

    High-purity Germanium (HPGe) detectors have reached an unprecedented level of sophistication and are still the best solution for high-resolution gamma spectroscopy. In the present work, we will show the results of the characterization of new surface treatments for the production of these detectors, studied in the framework of our multidisciplinary research program in HPGe detector technologies.

  14. Performance of Geant4 in simulating semiconductor particle detector response in the energy range below 1 MeV

    NASA Astrophysics Data System (ADS)

    Soti, G.; Wauters, F.; Breitenfeldt, M.; Finlay, P.; Kraev, I. S.; Knecht, A.; Porobić, T.; Zákoucký, D.; Severijns, N.

    2013-11-01

    Geant4 simulations play a crucial role in the analysis and interpretation of experiments providing low energy precision tests of the Standard Model. This paper focuses on the accuracy of the description of the electron processes in the energy range between 100 and 1000 keV. The effect of the different simulation parameters and multiple scattering models on the backscattering coefficients is investigated. Simulations of the response of HPGe and passivated implanted planar Si detectors to β particles are compared to experimental results. An overall good agreement is found between Geant4 simulations and experimental data.

  15. Background Model for the Majorana Demonstrator

    NASA Astrophysics Data System (ADS)

    Cuesta, C.; Abgrall, N.; Aguayo, E.; Avignone, F. T.; Barabash, A. S.; Bertrand, F. E.; Boswell, M.; Brudanin, V.; Busch, M.; Byram, D.; Caldwell, A. S.; Chan, Y.-D.; Christofferson, C. D.; Combs, D. C.; Detwiler, J. A.; Doe, P. J.; Efremenko, Yu.; Egorov, V.; Ejiri, H.; Elliott, S. R.; Fast, J. E.; Finnerty, P.; Fraenkle, F. M.; Galindo-Uribarri, A.; Giovanetti, G. K.; Goett, J.; Green, M. P.; Gruszko, J.; Guiseppe, V. E.; Gusev, K.; Hallin, A. L.; Hazama, R.; Hegai, A.; Henning, R.; Hoppe, E. W.; Howard, S.; Howe, M. A.; Keeter, K. J.; Kidd, M. F.; Kochetov, O.; Konovalov, S. I.; Kouzes, R. T.; LaFerriere, B. D.; Leon, J.; Leviner, L. E.; Loach, J. C.; MacMullin, J.; MacMullin, S.; Martin, R. D.; Meijer, S.; Mertens, S.; Nomachi, M.; Orrell, J. L.; O'Shaughnessy, C.; Overman, N. R.; Phillips, D. G.; Poon, A. W. P.; Pushkin, K.; Radford, D. C.; Rager, J.; Rielage, K.; Robertson, R. G. H.; Romero-Romero, E.; Ronquest, M. C.; Schubert, A. G.; Shanks, B.; Shima, T.; Shirchenko, M.; Snavely, K. J.; Snyder, N.; Suriano, A. M.; Thompson, J.; Timkin, V.; Tornow, W.; Trimble, J. E.; Varner, R. L.; Vasilyev, S.; Vetter, K.; Vorren, K.; White, B. R.; Wilkerson, J. F.; Wiseman, C.; Xu, W.; Yakushev, E.; Young, A. R.; Yu, C.-H.; Yumatov, V.

    The Majorana Collaboration is constructing a system containing 40 kg of HPGe detectors to demonstrate the feasibility and potential of a future tonne-scale experiment capable of probing the neutrino mass scale in the inverted-hierarchy region. To realize this, a major goal of the Majorana Demonstrator is to demonstrate a path forward to achieving a background rate at or below 1 cnt/(ROI-t-y) in the 4 keV region of interest around the Q-value at 2039 keV. This goal is pursued through a combination of a significant reduction of radioactive impurities in construction materials with analytical methods for background rejection, for example using powerful pulse shape analysis techniques profiting from the p-type point contact HPGe detectors technology. The effectiveness of these methods is assessed using simulations of the different background components whose purity levels are constrained from radioassay measurements.

  16. Field analyses of (238)U and (226)Ra in two uranium mill tailings piles from Niger using portable HPGe detector.

    PubMed

    Déjeant, Adrien; Bourva, Ludovic; Sia, Radia; Galoisy, Laurence; Calas, Georges; Phrommavanh, Vannapha; Descostes, Michael

    2014-11-01

    The radioactivities of (238)U and (226)Ra in mill tailings from the U mines of COMINAK and SOMAÏR in Niger were measured and quantified using a portable High-Purity Germanium (HPGe) detector. The (238)U and (226)Ra activities were measured under field conditions on drilling cores with 600s measurements and without any sample preparation. Field results were compared with those obtained by Inductive Coupled Plasma Atomic Emission Spectroscopy (ICP-AES) and emanometry techniques. This comparison indicates that gamma-ray absorption by such geological samples does not cause significant deviations. This work shows the feasibility of using portable HPGe detector in the field as a preliminary method to observe variations of radionuclides concentration with the aim of identifying samples of interest. The HPGe is particularly useful for samples with strong secular disequilibrium such as mill tailings. Copyright © 2014 Elsevier Ltd. All rights reserved.

  17. Development of a Compton suppressed gamma spectrometer using Monte Carlo techniques

    NASA Astrophysics Data System (ADS)

    Britton, Richard

    Gamma ray spectroscopy is routinely used to measure radiation in a number of situations. These include security applications, nuclear forensics studies, characterisation of radioactive sources, and environmental monitoring. For routine studies of environmental materials, the amount of radioactivity present is often very low, requiring spectroscopy systems which have to monitor the source for up to 7 days to achieve the required sensitivity. Recent developments in detector technology and data processing techniques have opened up the possibility of developing a highly efficient Compton Suppressed system, that was previously the preserve of large experimental collaborations. The accessibility of Monte-Carlo toolkits such as GEANT4 also provide the opportunity to optimise these systems using computer simulations, greatly reducing the need for expensive (and inefficient) testing in the laboratory. This thesis details the development of such a Compton Suppressed, planar HPGe detector system. Using the GEANT4 toolkit in combination with the experimental facilities at AWE, Aldermaston (which include HPGe detection systems, scintillator based detector systems, advanced shielding materials and gamma-gamma coincidence systems), simulations were built and validated to reproduce the detector response seen in the 'real-life' systems. This resulted in several improvements to the current system; for the shielding materials used, terrestrial and cosmic radiation were minimised, while reducing the X-ray fluorescence seen in the primary HPGe detector by an order of magnitude. With respect to the HPGe detector itself, an optimum thickness was identified for low energy (<300 keV) radiation, which maximised the efficiency for the energy range of interest while minimising the interaction probability for higher energy radionuclides (which are the primary cause of the Compton continuum that obscures lower energy decays). A combination of secondary detectors were then optimised to design a Compton Suppression system for the primary detector, which could improve the performance of the current Compton Suppression system by an order of magnitude. This equates to a reduction of the continuum by up to a factor of 240 for a nuclide such as Co-60, which is crucial for the detection of low-energy, low-activity emitters typically swamped by such a continuum. Finally, thoroughly optimised acquisition and analysis software has also been written to process data created by future high sensitivity gamma coincidence systems. This includes modules for the creation of histograms, coincidence matrices, and an ASCII to binary converter (for historical data) that has resulted in an analysis speed increase of up to 20000 times when compared to the software originally used for the extraction of coincidence information. Modules for low-energy time-walk correction and the removal of accidental coincidences are also included, which represent a capability that was not previously available.

  18. Identifying and quantifying short-lived fission products from thermal fission of HEU using portable HPGe detectors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pierson, Bruce D.; Finn, Erin C.; Friese, Judah I.

    2013-03-01

    Due to the emerging potential for trafficking of special nuclear material, research programs are investigating current capabilities of commercially available portable gamma ray detection systems. Presented in this paper are the results of three different portable high-purity germanium (HPGe) detectors used to identify short-lived fission products generated from thermal neutron interrogation of small samples of highly enriched uranium. Samples were irradiated at the Washington State University (WSU) Nuclear Radiation Center’s 1MW TRIGA reactor. The three portable, HPGe detectors used were the ORTEC MicroDetective, the ORTEC Detective, and the Canberra Falcon. Canberra’s GENIE-2000 software was used to analyze the spectral datamore » collected from each detector. Ultimately, these three portable detectors were able to identify a large range of fission products showing potential for material discrimination.« less

  19. Characterization of the first true coaxial 18-fold segmented n-type prototype HPGe detector for the GERDA project

    NASA Astrophysics Data System (ADS)

    Abt, I.; Caldwell, A.; Gutknecht, D.; Kröninger, K.; Lampert, M.; Liu, X.; Majorovits, B.; Quirion, D.; Stelzer, F.; Wendling, P.

    2007-07-01

    The first true coaxial 18-fold segmented n-type HPGe prototype detector produced by Canberra-France for the GERDA neutrinoless double beta-decay project was tested both at Canberra-France and at the Max-Planck-Institut für Physik in Munich. The main characteristics of the detector are given and measurements concerning detector properties are described. A novel method to establish contacts between the crystal and a Kapton cable is presented.

  20. Measurement and simulation of a Compton suppression system for safeguards application

    NASA Astrophysics Data System (ADS)

    Lee, Seung Kyu; Seo, Hee; Won, Byung-Hee; Lee, Chaehun; Shin, Hee-Sung; Na, Sang-Ho; Song, Dae-Yong; Kim, Ho-Dong; Park, Geun-Il; Park, Se-Hwan

    2015-11-01

    Plutonium (Pu) contents in spent nuclear fuels, recovered uranium (U) or uranium/transuranium (U/TRU) products must be measured in order to secure the safeguardability of a pyroprocessing facility. Self-induced X-Ray fluorescence (XRF) and gamma-ray spectroscopy are useful techniques for determining Pu-to-U ratios and Pu isotope ratios of spent fuel. Photon measurements of spent nuclear fuel by using high-resolution spectrometers such as high-purity germanium (HPGe) detectors show a large continuum background in the low-energy region, which is due in large part to Compton scattering of energetic gamma rays. This paper proposes a Compton suppression system for reducing of the Compton continuum background. In the present study, the system was configured by using an HPGe main detector and a BGO (bismuth germanate: Bi4Ge3O12) guard detector. The system performances for gamma-ray measurement and XRF were evaluated by means of Monte Carlo simulations and measurements of the radiation source. The Monte Carlo N-Particle eXtended (MCNPX) simulations were performed using the same geometry as for the experiments, and considered, for exact results, the production of secondary electrons and photons. As a performance test of the Compton suppression system, the peak-to-Compton ratio, which is a figure of merit to evaluate the gamma-ray detection, was enhanced by a factor of three or more when the Compton suppression system was used.

  1. Background model for the Majorana Demonstrator

    DOE PAGES

    Cuesta, C.; Abgrall, N.; Aguayo, E.; ...

    2015-01-01

    The Majorana Collaboration is constructing a system containing 40 kg of HPGe detectors to demonstrate the feasibility and potential of a future tonne-scale experiment capable of probing the neutrino mass scale in the inverted-hierarchy region. To realize this, a major goal of the Majorana Demonstrator is to demonstrate a path forward to achieving a background rate at or below 1 cnt/(ROI-t-y) in the 4 keV region of interest around the Q-value at 2039 keV. This goal is pursued through a combination of a significant reduction of radioactive impurities in construction materials with analytical methods for background rejection, for example usingmore » powerful pulse shape analysis techniques profiting from the p-type point contact HPGe detectors technology. The effectiveness of these methods is assessed using simulations of the different background components whose purity levels are constrained from radioassay measurements.« less

  2. Signal recognition efficiencies of artificial neural-network pulse-shape discrimination in HPGe -decay searches

    NASA Astrophysics Data System (ADS)

    Caldwell, A.; Cossavella, F.; Majorovits, B.; Palioselitis, D.; Volynets, O.

    2015-07-01

    A pulse-shape discrimination method based on artificial neural networks was applied to pulses simulated for different background, signal and signal-like interactions inside a germanium detector. The simulated pulses were used to investigate variations of efficiencies as a function of used training set. It is verified that neural networks are well-suited to identify background pulses in true-coaxial high-purity germanium detectors. The systematic uncertainty on the signal recognition efficiency derived using signal-like evaluation samples from calibration measurements is estimated to be 5 %. This uncertainty is due to differences between signal and calibration samples.

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Guinn, I.; Buuck, M.; Cuesta, C.

    The MAJORANA Collaboration will seek neutrinoless double beta decay (0νββ) in {sup 76}Ge using isotopically enriched p-type point contact (PPC) high purity Germanium (HPGe) detectors. A tonne-scale array of HPGe detectors would require background levels below 1 count/ROI-tonne-year in the 4 keV region of interest (ROI) around the 2039 keV Q-value of the decay. In order to demonstrate the feasibility of such an experiment, the MAJORANA DEMONSTRATOR, a 40 kg HPGe detector array, is being constructed with a background goal of < 3 count/ROI-tonne-year, which is expected to scale down to < 1 count/ROI-tonne-year for a tonne-scale experiment. The signalmore » readout electronics, which must be placed in close proximity to the detectors, present a challenge toward reaching this background goal. This talk will discuss the materials and design used to construct signal readout electronics with low enough backgrounds for the MAJORANA DEMONSTRATOR.« less

  4. Performance of a Facility for Measuring Scintillator Non-Proportionality

    NASA Astrophysics Data System (ADS)

    Choong, Woon-Seng; Hull, Giulia; Moses, William W.; Vetter, Kai M.; Payne, Stephen A.; Cherepy, Nerine J.; Valentine, John D.

    2008-06-01

    We have constructed a second-generation Compton coincidence instrument, known as the Scintillator Light Yield Non-proportionality Characterization Instrument (SLYNCI), to characterize the electron response of scintillating materials. While the SLYNCI design includes more and higher efficiency HPGe detectors than the original apparatus (five 25%-30% detectors versus one 10% detector), the most novel feature is that no collimator is placed in front of the HPGe detectors. Because of these improvements, the SLYNCI data collection rate is over 30 times higher than the original instrument. In this paper, we present a validation study of this instrument, reporting on the hardware implementation, calibration, and performance. We discuss the analysis method and present measurements of the electron response of two different NaI:Tl samples. We also discuss the systematic errors of the measurement, especially those that are unique to SLYNCI. We find that the apparatus is very stable, but that careful attention must be paid to the energy calibration of the HPGe detectors.

  5. Pulsed laser diffusion of thin hole-barrier contacts in high purity germanium for gamma radiation detectors

    NASA Astrophysics Data System (ADS)

    Maggioni, G.; Carturan, S.; Raniero, W.; Riccetto, S.; Sgarbossa, F.; Boldrini, V.; Milazzo, R.; Napoli, D. R.; Scarpa, D.; Andrighetto, A.; Napolitani, E.; De Salvador, D.

    2018-03-01

    A new method for the formation of hole-barrier contacts in high purity germanium (HPGe) is described, which consists in the sputter deposition of a Sb film on HPGe, followed by Sb diffusion produced through laser annealing of the Ge surface in the melting regime. This process gives rise to a very thin ( ≤ 100 nm) n-doped layer, as determined by SIMS measurement, while preserving the defect-free morphology of HPGe surface. A small prototype of gamma ray detector with a Sb laser-diffused contact was produced and characterized, showing low leakage currents and good spectroscopy data with different gamma ray sources.

  6. Monte Carlo Simulations for the Detection of Buried Objects Using Single Sided Backscattered Radiation.

    PubMed

    Yip, Mary; Saripan, M Iqbal; Wells, Kevin; Bradley, David A

    2015-01-01

    Detection of buried improvised explosive devices (IEDs) is a delicate task, leading to a need to develop sensitive stand-off detection technology. The shape, composition and size of the IEDs can be expected to be revised over time in an effort to overcome increasingly sophisticated detection methods. As an example, for the most part, landmines are found through metal detection which has led to increasing use of non-ferrous materials such as wood or plastic containers for chemical based explosives being developed. Monte Carlo simulations have been undertaken considering three different commercially available detector materials (hyperpure-Ge (HPGe), lanthanum(III) bromide (LaBr) and thallium activated sodium iodide (NaI(Tl)), applied at a stand-off distance of 50 cm from the surface and burial depths of 0, 5 and 10 cm, with sand as the obfuscating medium. Target materials representing medium density wood and mild steel have been considered. Each detector has been modelled as a 10 cm thick cylinder with a 20 cm diameter. It appears that HPGe represents the most promising detector for this application. Although it was not the highest density material studied, its excellent energy resolving capability leads to the highest quality spectra from which detection decisions can be inferred. The simulation work undertaken here suggests that a vehicle-born threat detection system could be envisaged using a single betatron and a series of detectors operating in parallel observing the space directly in front of the vehicle path. Furthermore, results show that non-ferrous materials such as wood can be effectively discerned in such remote-operated detection system, with the potential to apply a signature analysis template matching technique for real-time analysis of such data.

  7. Estimation of neutron spectrum in the low-level gamma spectroscopy system using unfolding procedure

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Knežević, D., E-mail: david.knezevic@df.uns.ac.rs; Jovančević, N.; Krmar, M.

    2016-03-25

    The radiation resulting from neutron interactions with Ge nuclei in active volume of HPGe detectors is one of the main concerns in low-level gamma spectroscopy measurements [1,2]. It is usually not possible to measure directly spectrum of neutrons which strike detector. This paper explore the possibility of estimation of neutron spectrum using measured activities of certain Ge(n,γ) and Ge(n,n’) reactions (obtained from low-level gamma measurements), available ENDF cross section data and unfolding procedures. In this work HPGe detector with passive shield made from commercial low background lead was used for the measurement. The most important objective of this study wasmore » to reconstruct muon induced neutron spectrum created in the shield of the HPGe detector. MAXED [3] and GRAVEL [4] algorithms for neutron spectra unfolding were used. The results of those two algorithms were compared and we analyzed the sensitivity of the unfolding procedure to the various input parameters.« less

  8. Mod 1 ICS TI Report: ICS Conversion of a 140% HPGe Detector

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bounds, John Alan

    This report evaluates the Mod 1 ICS, an electrically cooled 140% HPGe detector. It is a custom version of the ORTEC Integrated Cooling System (ICS) modified to make it more practical for us to use in the field. Performance and operating characteristics of the Mod 1 ICS are documented, noting both pros and cons. The Mod 1 ICS is deemed a success. Recommendations for a Mod 2 ICS, a true field prototype, are provided.

  9. Intercomparison NaI(Tl) and HPGe spectrometry to studies of natural radioactivity on geological samples.

    PubMed

    Hung, Nguyen Quoc; Chuong, Huynh Dinh; Vuong, Le Quang; Thanh, Tran Thien; Tao, Chau Van

    2016-11-01

    In this study, in situ gamma spectra using NaI(Tl) detector have been compared with the laboratory measurements by using HPGe detector on geological samples. The results for measuring naturally occurring terrestrial gamma radiation of 4 0 K and the decay series of 232 Th and, 238 U respectively of both detectors show a maximum deviation about 5%. The mass activities series from both detectors were checked for coherence using proficiency test procedure from the International Atomic Energy Agency. The reliability and precision pass for final scores for all the analytical determinations of are received "acceptable" for all radionuclides. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. High voltage testing for the Majorana Demonstrator

    DOE PAGES

    Abgrall, N.; Arnquist, I. J.; Avignone, III, F. T.; ...

    2016-04-04

    The Majorana Collaboration is constructing the Majorana Demonstrator, an ultra-low background, 44-kg modular high-purity Ge (HPGe) detector array to search for neutrinoless double-beta decay in 76Ge. The phenomenon of surface micro-discharge induced by high-voltage has been studied in the context of the Majorana Demonstrator. This effect can damage the front-end electronics or mimic detector signals. To ensure the correct performance, every high-voltage cable and feedthrough must be capable of supplying HPGe detector operating voltages as high as 5 kV without exhibiting discharge. R&D measurements were carried out to understand the testing system and determine the optimum design configuration of themore » high-voltage path, including different improvements of the cable layout and feedthrough flange model selection. Every cable and feedthrough to be used at the Majorana Demonstrator was characterized and the micro-discharge effects during the Majorana Demonstrator commissioning phase were studied. Furthermore, a stable configuration has been achieved, and the cables and connectors can supply HPGe detector operating voltages without exhibiting discharge.« less

  11. High voltage testing for the Majorana Demonstrator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abgrall, N.; Arnquist, Isaac J.; Avignone, F. T.

    2016-07-01

    The Majorana Collaboration is constructing theMajorana Demonstrator, an ultra-low background, 44-kg modular high-purity Ge (HPGe) detector array to search for neutrinoless double-beta decay in 76Ge. The phenomenon of surface micro-discharge induced by high-voltage has been studied in the context of theMajorana Demonstrator. This effect can damage the front-end electronics or mimic detector signals. To ensure the correct performance, every high-voltage cable and feedthrough must be capable of supplying HPGe detector operating voltages as high as 5 kV without exhibiting discharge. R&D measurements were carried out to understand the testing system and determine the optimum design configuration of the high-voltage path,more » including different improvements of the cable layout and feedthrough flange model selection. Every cable and feedthrough to be used at the Majorana Demonstrator was characterized and the micro-discharge effects during theMajorana Demonstrator commissioning phase were studied. A stable configuration has been achieved, and the cables and connectors can supply HPGe detector operating voltages without exhibiting discharge.« less

  12. Performance of a segmented HPGe detector at KRISS.

    PubMed

    Han, Jubong; Lee, K B; Lee, Jong-Man; Lee, S H; Park, Tae Soon; Oh, J S

    2018-04-01

    A 24 segmented HPGe coaxial detector was set up with a digitized data acquisition system (DAQ). The DAQ was composed of a digitizer (5 × 10 7 sampling/s), a Field-Programmable Gate Array (FPGA), and a real time operating system. The Full Width Half Maximum (FWHM), rise time, signal characteristics, and spectra of a 137 Cs source were evaluated. The data were processed using an in-house developed gamma-ray tracking system. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. HPGe detector shielding optimization with MCNPX for the MEDINA PGNAA cell

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nicol, T.; Perot, B.; Carasco, C.

    2015-07-01

    Radioactive waste repositories must guarantee the non-toxicity of the waste in the long term, not only regarding radioactivity but also regarding other environmental contamination such as toxic chemicals. Analytical methods already exist for chemical characterization (ICP-MS, ICP-AES...) but they are based on test sampling. A possible alternative, for waste packages with an appropriate gamma radiation level, is to use Prompt Gamma Neutron Activation Analysis (PGNAA), a non-destructive measurement technique sensitive to several toxic chemicals. In view of the characterization of radioactive wastes in Germany and France, collaboration between the CEA Cadarache (France) and the Forschungszentrum Juelich (Germany) was initiated amore » few years ago. FZJ holds a PGNAA graphite cell called MEDINA (Multi Element Detection based on Instrumental Neutron Activation), allowing the characterization of 225 L drums. Fast neutrons are emitted from a D-T pulsed 14 MeV neutron generator and thermalized in graphite to induced radiative captures in the waste materials. Prompt capture gamma rays are detected using a 104% relative efficiency n-type HPGe. However, HPGe crystal is sensitive to fast neutron damage and to thermal neutron activation. A thermal neutron shield made of lithium fluorine and lithium carbonate is already used around the detector. In order to further decrease the current of fast and thermal neutrons coming into the crystal without penalizing MEDINA sensitivity (by decreasing the thermal neutron flux and neutron die away time of the cell, the gamma detection efficiency, or increasing the gamma background), some configurations based on easy-to-implement modifications of MEDINA have been simulated with MCNPX with a model of the cell already validated by experiments. Results show that fast and thermal neutron incoming current in the HPGe could easily be reduced by about a factor of 2 by additional quantities of graphite and by replacing lithium carbonate by lithium fluorine with a higher {sup 6}Li concentration. In addition, these modifications slightly increase the thermal neutron flux in the cell without deteriorating the neutron die away time, and reduce the gamma background about a factor of 2 during the neutron pulse but 5 times less after it. More important changes have also been tested, such as the addition of polyethylene and lead between the neutron generator and the HPGe detector, which is more effective regarding neutron shielding but decreases the neutron die away time, partly compensated by a larger initial thermal neutron flux. Concerning gamma background, hydrogen capture gamma ray (2.23 MeV) is increased due to the presence of polyethylene but lead around the HPGe decreases the total gamma background. In conclusion, simple modifications are possible to improve detector shielding and life time before thermal annealing of the crystal, without reducing MEDINA cell performances. Some of these modifications will be tested in the coming months. (authors)« less

  14. Background Model for the Majorana Demonstrator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cuesta, C.; Abgrall, N.; Aguayo, Estanislao

    2015-06-01

    The Majorana Collaboration is constructing a prototype system containing 40 kg of HPGe detectors to demonstrate the feasibility and potential of a future tonne-scale experiment to search for neutrinoless double-beta (0v BB) decay in 76Ge. In view of the requirement that the next generation of tonne-scale Ge-based 0vBB-decay experiment be capable of probing the neutrino mass scale in the inverted-hierarchy region, a major goal of theMajorana Demonstrator is to demonstrate a path forward to achieving a background rate at or below 1 cnt/(ROI-t-y) in the 4 keV region of interest around the Q-value at 2039 keV. This goal is pursuedmore » through a combination of a significant reduction of radioactive impurities in construction materials with analytical methods for background rejection, for example using powerful pulse shape analysis techniques profiting from the p-type point contact HPGe detectors technology. The effectiveness of these methods is assessed using Geant4 simulations of the different background components whose purity levels are constrained from radioassay measurements.« less

  15. Improved plutonium identification and characterization results with NaI(Tl) detector using ASEDRA

    NASA Astrophysics Data System (ADS)

    Detwiler, R.; Sjoden, G.; Baciak, J.; LaVigne, E.

    2008-04-01

    The ASEDRA algorithm (Advanced Synthetically Enhanced Detector Resolution Algorithm) is a tool developed at the University of Florida to synthetically enhance the resolved photopeaks derived from a characteristically poor resolution spectra collected at room temperature from scintillator crystal-photomultiplier detector, such as a NaI(Tl) system. This work reports on analysis of a side-by-side test comparing the identification capabilities of ASEDRA applied to a NaI(Tl) detector with HPGe results for a Plutonium Beryllium (PuBe) source containing approximately 47 year old weapons-grade plutonium (WGPu), a test case of real-world interest with a complex spectra including plutonium isotopes and 241Am decay products. The analysis included a comparison of photopeaks identified and photopeak energies between the ASEDRA and HPGe detector systems, and the known energies of the plutonium isotopes. ASEDRA's performance in peak area accuracy, also important in isotope identification as well as plutonium quality and age determination, was evaluated for key energy lines by comparing the observed relative ratios of peak areas, adjusted for efficiency and attenuation due to source shielding, to the predicted ratios from known energy line branching and source isotopics. The results show that ASEDRA has identified over 20 lines also found by the HPGe and directly correlated to WGPu energies.

  16. Precise determination of neutron binding energy of 64Cu

    NASA Astrophysics Data System (ADS)

    Telezhnikov, S. A.; Granja, C.; Honzatko, J.; Pospisil, S.; Tomandl, I.

    2016-05-01

    The neutron binding energy in 64Cu has been accurately measured in thermal neutron capture. A composite target of natural Cu and NaCl was used on a high flux neutron beam using a large measuring time. The γ-ray spectrum emitted in the ( n, γ) reaction was measured with a HPGe detector in large statistics (up to 106 events per channel). Intrinsic limitations of HPGe detectors, which restrict the accuracy of energy calibration, were determined. The value B n of 64Cu was determined as 7915.867(24) keV.

  17. Nuclear resonance fluorescence in U-238 using LaBr detectors for nuclear security

    NASA Astrophysics Data System (ADS)

    Hayakawa, Takehito; Negm, Hani; Ohgaki, Hideaki; Daito, Izuru; Kii, Toshiteru; Zen, Heishun; Omer, Mohamed; Shizuma, Toshiyuki; Hajima, Ryoichi

    2014-09-01

    Recently, a nondestructive measurement method of shielded fissional isotopes such as 235U or 239Pu has been proposed for the nuclear security. These isotopes are measured by using nuclear resonance fluorescence (NRF) with monochromatic energy gamma-ray beams generated by laser Compton-scattering (LCS). We have proposed that one measure scattered gamma-rays from NRF with LCS gamma-ray beams using the LaBr3(Ce) detectors. The LaBr3(Ce) crystals include internal radioisotopes of a meta-stable isotope 138La and alpha decay chains from some actinides as 227Ac. There is a broad pump at about 2 MeV. This pump is considered to be an overlap of alpha-rays from decay chains of some actinides but its detailed structure has not been established. Here we have measured NRF spectra of 238U using the LCS gamma-rays with energy of about 2.5 MeV at the HIgS facility of the Duke University. The background has been evaluated using a simulation code GEAT4. The 9 peaks, 8 NRF gamma-rays plus the Compton scattered gamma-ray of the incident beam, are finally assigned in an energy range of about 200 keV at about 2.5 MeV. The 8 integrated NRF cross-sections measured by LaBr3(Ce) have been consistent with results by an HPGe detector. The three levels are newly assigned using the HPGe detector. Two of them are also measured by LaBr3(Ce).

  18. Purification of Germanium Crystals by Zone Refining

    NASA Astrophysics Data System (ADS)

    Kooi, Kyler; Yang, Gang; Mei, Dongming

    2016-09-01

    Germanium zone refining is one of the most important techniques used to produce high purity germanium (HPGe) single crystals for the fabrication of nuclear radiation detectors. During zone refining the impurities are isolated to different parts of the ingot. In practice, the effective isolation of an impurity is dependent on many parameters, including molten zone travel speed, the ratio of ingot length to molten zone width, and number of passes. By studying the theory of these influential factors, perfecting our cleaning and preparation procedures, and analyzing the origin and distribution of our impurities (aluminum, boron, gallium, and phosphorous) identified using photothermal ionization spectroscopy (PTIS), we have optimized these parameters to produce HPGe. We have achieved a net impurity level of 1010 /cm3 for our zone-refined ingots, measured with van der Pauw and Hall-effect methods. Zone-refined ingots of this purity can be processed into a detector grade HPGe single crystal, which can be used to fabricate detectors for dark matter and neutrinoless double beta decay detection. This project was financially supported by DOE Grant (DE-FG02-10ER46709) and the State Governor's Research Center.

  19. A method for the complete analysis of NORM building materials by γ-ray spectrometry using HPGe detectors.

    PubMed

    Quintana, B; Pedrosa, M C; Vázquez-Canelas, L; Santamaría, R; Sanjuán, M A; Puertas, F

    2018-04-01

    A methodology including software tools for analysing NORM building materials and residues by low-level gamma-ray spectrometry has been developed. It comprises deconvolution of gamma-ray spectra using the software GALEA with focus on the natural radionuclides and Monte Carlo simulations for efficiency and true coincidence summing corrections. The methodology has been tested on a range of building materials and validated against reference materials. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Search for double beta decay with HPGe detectors at the Gran Sasso underground laboratory

    NASA Astrophysics Data System (ADS)

    Chkvorets, Oleg

    2008-12-01

    Neutrinoless double-beta decay is practically the only way to establish the Majorana nature of the neutrino mass and its decay rate provides a probe of an effective neutrino mass. Double beta experiments are long-running underground experiments with specific challenges concerning the background reduction and the long term stability. These problems are addressed in this work for the Heidelberg-Moscow (HdM), GENIUS Test Facility (TF) and GERDA experiments. The HdM experiment collected data with enriched 76Ge high purity (HPGe) detectors from 1990 to 2003. An improved analysis of HdM data is presented, exploiting new calibration and spectral shape measurements with the HdM detectors. GENIUS-TF was a test-facility that verified the feasibility of using bare germanium detectors in liquid nitrogen. The first year results of this experiment are discussed. The GERDA experiment has been designed to further increase the sensitivity by operating bare germanium detectors in a high purity cryogenic liquid, which simultaneously serves as a shielding against background and as a cooling media. In the preparatory stage of GERDA, an external background gamma flux measurement was done at the experimental site in the Hall A of the Gran Sasso laboratory. The characterization of the enriched detectors from the HdM and IGEX experiments was performed in the underground detector laboratory for the GERDA collaboration. Long term stability measurements of a bare HPGe detector in liquid argon were carried out. Based on these measurements, the first lower limit on the half-life of neutrinoless double electron capture of 36Ar was established to be 1.85*10^18 years at 68% C.L.

  1. Efficiency transfer using the GEANT4 code of CERN for HPGe gamma spectrometry.

    PubMed

    Chagren, S; Tekaya, M Ben; Reguigui, N; Gharbi, F

    2016-01-01

    In this work we apply the GEANT4 code of CERN to calculate the peak efficiency in High Pure Germanium (HPGe) gamma spectrometry using three different procedures. The first is a direct calculation. The second corresponds to the usual case of efficiency transfer between two different configurations at constant emission energy assuming a reference point detection configuration and the third, a new procedure, consists on the transfer of the peak efficiency between two detection configurations emitting the gamma ray in different energies assuming a "virtual" reference point detection configuration. No pre-optimization of the detector geometrical characteristics was performed before the transfer to test the ability of the efficiency transfer to reduce the effect of the ignorance on their real magnitude on the quality of the transferred efficiency. The obtained and measured efficiencies were found in good agreement for the two investigated methods of efficiency transfer. The obtained agreement proves that Monte Carlo method and especially the GEANT4 code constitute an efficient tool to obtain accurate detection efficiency values. The second investigated efficiency transfer procedure is useful to calibrate the HPGe gamma detector for any emission energy value for a voluminous source using one point source detection efficiency emitting in a different energy as a reference efficiency. The calculations preformed in this work were applied to the measurement exercise of the EUROMET428 project. A measurement exercise where an evaluation of the full energy peak efficiencies in the energy range 60-2000 keV for a typical coaxial p-type HpGe detector and several types of source configuration: point sources located at various distances from the detector and a cylindrical box containing three matrices was performed. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. Development of a transportable neutron activation analysis system to quantify manganese in bone in vivo: feasibility and methodology.

    PubMed

    Liu, Yingzi; Koltick, David; Byrne, Patrick; Wang, Haoyu; Zheng, Wei; Nie, Linda H

    2013-12-01

    This study was conducted to investigate the methodology and feasibility of developing a transportable neutron activation analysis (NAA) system to quantify manganese (Mn) in bone using a portable deuterium-deuterium (DD) neutron generator as the neutron source. Since a DD neutron generator was not available in our laboratory, a deuterium-tritium (DT) neutron generator was used to obtain experimental data and validate the results from Monte Carlo (MC) simulations. After validation, MC simulations using a DD generator as the neutron source were then conducted. Different types of moderators and reflectors were simulated, and the optimal thicknesses for the moderator and reflector were determined. To estimate the detection limit (DL) of the system, and to observe the interference of the magnesium (Mg) γ line at 844 keV to the Mn γ line at 847 keV, three hand phantoms with Mn concentrations of 30 parts per million (ppm), 150 ppm, and 500 ppm were made and irradiated by the DT generator system. The Mn signals in these phantoms were then measured using a 50% high-efficiency high-purity germanium (HPGe) detector. The DL was calculated to be about 4.4 ppm for the chosen irradiation, decay, and measurement time. This was calculated to be equivalent to a DL of about 3.3 ppm for the DD generator system. To achieve this DL with one 50% high-efficiency HPGe detector, the dose to the hand was simulated to be about 37 mSv, with the total body equivalent dose being about 23µSv. In conclusion, it is feasible to develop a transportable NAA system to quantify Mn in bone in vivo with an acceptable radiation exposure to the subject.

  3. Development of a transportable neutron activation analysis system to quantify manganese in bone in vivo: feasibility and methodology

    PubMed Central

    Liu, Yingzi; Koltick, David; Byrne, Patrick; Wang, Haoyu; Zheng, Wei; Nie, Linda H

    2014-01-01

    This study was conducted to investigate the methodology and feasibility of developing a transportable neutron activation analysis (NAA) system to quantify manganese (Mn) in bone using a portable deuterium–deuterium (DD) neutron generator as the neutron source. Since a DD neutron generator was not available in our laboratory, a deuterium–tritium (DT) neutron generator was used to obtain experimental data and validate the results from Monte Carlo (MC) simulations. After validation, MC simulations using a DD generator as the neutron source were then conducted. Different types of moderators and reflectors were simulated, and the optimal thicknesses for the moderator and reflector were determined. To estimate the detection limit (DL) of the system, and to observe the interference of the magnesium (Mg) γ line at 844 keV to the Mn γ line at 847 keV, three hand phantoms with Mn concentrations of 30 parts per million (ppm), 150 ppm, and 500 ppm were made and irradiated by the DT generator system. The Mn signals in these phantoms were then measured using a 50% high-efficiency high-purity germanium (HPGe) detector. The DL was calculated to be about 4.4 ppm for the chosen irradiation, decay, and measurement time. This was calculated to be equivalent to a DL of about 3.3 ppm for the DD generator system. To achieve this DL with one 50% high-efficiency HPGe detector, the dose to the hand was simulated to be about 37 mSv, with the total body equivalent dose being about 23μSv. In conclusion, it is feasible to develop a transportable NAA system to quantify Mn in bone in vivo with an acceptable radiation exposure to the subject. PMID:24165395

  4. Gamma-ray Full Spectrum Analysis for Environmental Radioactivity by HPGe Detector

    NASA Astrophysics Data System (ADS)

    Jeong, Meeyoung; Lee, Kyeong Beom; Kim, Kyeong Ja; Lee, Min-Kie; Han, Ju-Bong

    2014-12-01

    Odyssey, one of the NASA¡¯s Mars exploration program and SELENE (Kaguya), a Japanese lunar orbiting spacecraft have a payload of Gamma-Ray Spectrometer (GRS) for analyzing radioactive chemical elements of the atmosphere and the surface. In these days, gamma-ray spectroscopy with a High-Purity Germanium (HPGe) detector has been widely used for the activity measurements of natural radionuclides contained in the soil of the Earth. The energy spectra obtained by the HPGe detectors have been generally analyzed by means of the Window Analysis (WA) method. In this method, activity concentrations are determined by using the net counts of energy window around individual peaks. Meanwhile, an alternative method, the so-called Full Spectrum Analysis (FSA) method uses count numbers not only from full-absorption peaks but from the contributions of Compton scattering due to gamma-rays. Consequently, while it takes a substantial time to obtain a statistically significant result in the WA method, the FSA method requires a much shorter time to reach the same level of the statistical significance. This study shows the validation results of FSA method. We have compared the concentration of radioactivity of 40K, 232Th and 238U in the soil measured by the WA method and the FSA method, respectively. The gamma-ray spectrum of reference materials (RGU and RGTh, KCl) and soil samples were measured by the 120% HPGe detector with cosmic muon veto detector. According to the comparison result of activity concentrations between the FSA and the WA, we could conclude that FSA method is validated against the WA method. This study implies that the FSA method can be used in a harsh measurement environment, such as the gamma-ray measurement in the Moon, in which the level of statistical significance is usually required in a much shorter data acquisition time than the WA method.

  5. TIGRESS highly-segmented high-purity germanium clover detector

    NASA Astrophysics Data System (ADS)

    Scraggs, H. C.; Pearson, C. J.; Hackman, G.; Smith, M. B.; Austin, R. A. E.; Ball, G. C.; Boston, A. J.; Bricault, P.; Chakrawarthy, R. S.; Churchman, R.; Cowan, N.; Cronkhite, G.; Cunningham, E. S.; Drake, T. E.; Finlay, P.; Garrett, P. E.; Grinyer, G. F.; Hyland, B.; Jones, B.; Leslie, J. R.; Martin, J.-P.; Morris, D.; Morton, A. C.; Phillips, A. A.; Sarazin, F.; Schumaker, M. A.; Svensson, C. E.; Valiente-Dobón, J. J.; Waddington, J. C.; Watters, L. M.; Zimmerman, L.

    2005-05-01

    The TRIUMF-ISAC Gamma-Ray Escape-Suppressed Spectrometer (TIGRESS) will consist of twelve units of four high-purity germanium (HPGe) crystals in a common cryostat. The outer contacts of each crystal will be divided into four quadrants and two lateral segments for a total of eight outer contacts. The performance of a prototype HPGe four-crystal unit has been investigated. Integrated noise spectra for all contacts were measured. Energy resolutions, relative efficiencies for both individual crystals and for the entire unit, and peak-to-total ratios were measured with point-like sources. Position-dependent performance was measured by moving a collimated source across the face of the detector.

  6. Efficiency study of a big volume well type NaI(Tl) detector by point and voluminous sources and Monte-Carlo simulation.

    PubMed

    Hansman, Jan; Mrdja, Dusan; Slivka, Jaroslav; Krmar, Miodrag; Bikit, Istvan

    2015-05-01

    The activity of environmental samples is usually measured by high resolution HPGe gamma spectrometers. In this work a set-up with a 9in.x9in. NaI well-detector with 3in. thickness and a 3in.×3in. plug detector in a 15-cm-thick lead shielding is considered as an alternative (Hansman, 2014). In spite of its much poorer resolution, it requires shorter measurement times and may possibly give better detection limits. In order to determine the U-238, Th-232, and K-40 content in the samples by this NaI(Tl) detector, the corresponding photopeak efficiencies must be known. These efficiencies can be found for certain source matrix and geometry by Geant4 simulation. We found discrepancy between simulated and experimental efficiencies of 5-50%, which can be mainly due to effects of light collection within the detector volume, an effect which was not taken into account by simulations. The influence of random coincidence summing on detection efficiency for radionuclide activities in the range 130-4000Bq, was negligible. This paper describes also, how the efficiency in the detector depends on the position of the radioactive point source. To avoid large dead time, relatively weak Mn-54, Co-60 and Na-22 point sources of a few kBq were used. Results for single gamma lines and also for coincidence summing gamma lines are presented. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. Design and Optimization of a Dual-HPGe Gamma Spectrometer and Its Cosmic Veto System

    NASA Astrophysics Data System (ADS)

    Zhang, Weihua; Ro, Hyunje; Liu, Chuanlei; Hoffman, Ian; Ungar, Kurt

    2017-03-01

    In this paper, a dual high purity germanium (HPGe) gamma spectrometer detection system with an increased solid angle was developed. The detection system consists of a pair of Broad Energy Germanium (BE-5030p) detectors and an XIA LLC digital gamma finder/Pixie-4 data-acquisition system. A data file processor was developed containing five modules that parses Pixie-4 list-mode data output files and classifies detections into anticoincident/coincident events and their specific coincidence types (double/triple/quadruple) for further analysis. A novel cosmic veto system was installed in the detection system. It was designed to be easy to install around an existing system while still providing sufficient cosmic veto shielding comparable to other designs. This paper describes the coverage and efficiency of this cosmic veto and the data processing system. It has been demonstrated that the cosmic veto system can provide a mean background reduction of 66.1%, which results in a mean MDA improvement of 58.3%. The counting time to meet the required MDA for specific radionuclide can be reduced by a factor of 2-3 compared to those using a conventional HPGe system. This paper also provides an initial overview of coincidence timing distributions between an incoming event from a cosmic veto plate and HPGe detector.

  8. Development of an underground HPGe array facility for ultra low radioactivity measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sala, E.; Kang, W. G.; Kim, Y. D.

    Low Level Counting techniques using low background facilities are continuously under development to increase the possible sensitivity needed for rare physics events experiments. The CUP (Center for Underground Physics) group of IBS is developing, in collaboration with Canberra, a ultra low background instrument composed of two arrays facing each other with 7 HPGe detectors each. The low radioactive background of each detector has been evaluated and improved by the material selection of the detector components. Samples of all the building materials have been provided by the manufacturer and the contaminations had been measured using an optimized low background 100% HPGemore » with a dedicated shielding. The evaluation of the intrinsic background has been performed using MonteCarlo simulations and considering the contribution of each material with the measured contamination. To further reduce the background, the instrument will be placed in the new underground laboratory at YangYang exploiting the 700m mountain coverage and radon-free air supplying system. The array has been designed to perform various Ultra Low background measurements; the sensitivity we are expecting will allow not only low level measurements of Ra and Th contaminations in Copper or other usually pure materials, but also the search for rare decays. In particular some possible candidates and configurations to detect the 0νECEC (for example {sup 106}Cd and {sup 156}Dy) and rare β decays ({sup 96}Zr, {sup 180m}Ta , etc ) are under study.« less

  9. Efficiency calibration and minimum detectable activity concentration of a real-time UAV airborne sensor system with two gamma spectrometers.

    PubMed

    Tang, Xiao-Bin; Meng, Jia; Wang, Peng; Cao, Ye; Huang, Xi; Wen, Liang-Sheng; Chen, Da

    2016-04-01

    A small-sized UAV (NH-UAV) airborne system with two gamma spectrometers (LaBr3 detector and HPGe detector) was developed to monitor activity concentration in serious nuclear accidents, such as the Fukushima nuclear accident. The efficiency calibration and determination of minimum detectable activity concentration (MDAC) of the specific system were studied by MC simulations at different flight altitudes, different horizontal distances from the detection position to the source term center and different source term sizes. Both air and ground radiation were considered in the models. The results obtained may provide instructive suggestions for in-situ radioactivity measurements of NH-UAV. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. Summing coincidence correction for γ-ray measurements using the HPGe detector with a low background shielding system

    NASA Astrophysics Data System (ADS)

    He, L.-C.; Diao, L.-J.; Sun, B.-H.; Zhu, L.-H.; Zhao, J.-W.; Wang, M.; Wang, K.

    2018-02-01

    A Monte Carlo method based on the GEANT4 toolkit has been developed to correct the full-energy peak (FEP) efficiencies of a high purity germanium (HPGe) detector equipped with a low background shielding system, and moreover evaluated using summing peaks in a numerical way. It is found that the FEP efficiencies of 60Co, 133Ba and 152Eu can be improved up to 18% by taking the calculated true summing coincidence factors (TSCFs) correction into account. Counts of summing coincidence γ peaks in the spectrum of 152Eu can be well reproduced using the corrected efficiency curve within an accuracy of 3%.

  11. Obelix, a new low-background HPGe at Modane Underground Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Loaiza, P.; LAL, Univ. Paris-Sud, CNRS/IN2P3, 91405 Orsay; Brudanin, V.

    An ultra-low background coaxial HPGe detector for gamma-ray spectrometry with a relative efficiency of 160%, corresponding to a 600 cm{sup 3} Ge crystal, was installed at the Laboratoire Souterrain de Modane, France (4800 m.w.e). To reduce the instrinsic detector background, all parts involved in the detector cryostat were selected for their low radioactivity contamination. A shielding, composed of an inner layer of roman lead and an external layer of regular lead was installed, together with a system to reduce the Rn level inside the sample chamber. The shielding was designed to allow the measurement of Marinelli-shaped samples. We present the constructional detailsmore » which lead to a remarkable low detector background of 73 cts/kg·d in [40, 3000] keV. Measured samples showed that sensitivities about 100 μBq/kg in {sup 226}Ra and {sup 228}Th are reached for samples of some kg and 30 days of lifetime.« less

  12. Comparison of experimental results of a Quad-CZT array detector, a NaI(Tl), a LaBr3(Ce), and a HPGe for safeguards applications

    NASA Astrophysics Data System (ADS)

    Kwak, S.-W.; Choi, J.; Park, S. S.; Ahn, S. H.; Park, J. S.; Chung, H.

    2017-11-01

    A compound semiconductor detector, CdTe (or CdZnTe), has been used in various areas including nuclear safeguards applications. To address its critical drawback, low detection efficiency, which leads to a long measurement time, a Quad-CZT array-based gamma-ray spectrometer in our previous study has been developed by combining four individual CZT detectors. We have re-designed the developed Quad-CZT array system to make it more simple and compact for a hand-held gamma-ray detector. The objective of this paper aims to compare the improved Quad-CZT array system with the traditional gamma-ray spectrometers (NaI(Tl), LaBr3(Ce), HPGe); these detectors currently have been the most commonly used for verification of nuclear materials. Nuclear materials in different physical forms in a nuclear facility of Korea were measured by the Quad-CZT array system and the existing gamma-ray detectors. For measurements of UO2 pellets and powders, and fresh fuel rods, the Quad-CZT array system turned out to be superior to the NaI(Tl) and LaBr3(Ce). For measurements of UF6 cylinders with a thick wall, the Quad-CZT array system and HPGe gave similar accuracy under the same measurement time. From the results of the field tests conducted, we can conclude that the improved Quad-CZT array system would be used as an alternative to HPGes and scintillation detectors for the purpose of increasing effectivenss and efficiency of safeguards applications. This is the first paper employing a multi-element CZT array detector for measurement of nuclear materials—particularly uranium in a UF6 cylinder—in a real nuclear facility. The present work also suggests that the multi-CZT array system described in this study would be one promising method to address a serious weakness of CZT-based radiation detection.

  13. Background rejection of n+ surface events in GERDA Phase II

    NASA Astrophysics Data System (ADS)

    Lehnert, Björn

    2016-05-01

    The GERDA experiment searches for neutrinoless double beta (0vββ) decay in 76Ge using an array of high purity germanium (HPGe) detectors immersed in liquid argon (LAr). Phase II of the experiment uses 30 new broad energy germanium (BEGe) detectors with superior pulse shape discrimination capabilities compared to the previously used semi-coaxial detector design. By far the largest background component for BEGe detectors in GERDA are n+-surface events from 42K β decays which are intrinsic in LAr. The β particles with up to 3.5 MeV can traverse the 0.5 to 0.9 mm thick electrode and deposit energy within the region of interest for the 0vββ decay. However, those events have particular pulse shape features allowing for a strong discrimination. The understanding and simulation of this background, showing a reduction by up to a factor 145 with pulse shape discrimination alone, is presented in this work.

  14. Improving axion detection sensitivity in high purity germanium detector based experiments

    NASA Astrophysics Data System (ADS)

    Xu, Wenqin; Elliott, Steven

    2015-04-01

    Thanks to their excellent energy resolution and low energy threshold, high purity germanium (HPGe) crystals are widely used in low background experiments searching for neutrinoless double beta decay, e.g. the MAJORANA DEMONSTRATOR and the GERDA experiments, and low mass dark matter, e.g. the CDMS and the EDELWEISS experiments. A particularly interesting candidate for low mass dark matter is the axion, which arises from the Peccei-Quinn solution to the strong CP problem and has been searched for in many experiments. Due to axion-photon coupling, the postulated solar axions could coherently convert to photons via the Primakeoff effect in periodic crystal lattices, such as those found in HPGe crystals. The conversion rate depends on the angle between axions and crystal lattices, so the knowledge of HPGe crystal axis is important. In this talk, we will present our efforts to improve the HPGe experimental sensitivity to axions by considering the axis orientations in multiple HPGe crystals simultaneously. We acknowledge the support of the U.S. Department of Energy through the LANL/LDRD Program.

  15. Optimal Cooling of High Purity Germanium Spectrometers for Missions to Planets and Moons

    NASA Astrophysics Data System (ADS)

    Chernenko, A.; Kostenko, V.; Konev, S.; Rybkin, B.; Paschin, A.; Prokopenko, I.

    2004-04-01

    Gamma-ray spectrometers based on high purity germanium (HPGe) detectors are ultimately sensitive instruments for composition studies of surfaces of planets and moons. However, they require deep cooling well below 120K for the entire duration of space mission, and this challenges the feasibility of such instruments in the era of small and cost-efficient missions. In this paper we summarise our experience in the field of the theoretical and experimental studies of optimal cryogenic cooling of gamma-ray spectrometers based on HPGe detectors in order to find out how efficient, light and compact these instruments could be, provided such technologies like cryogenic heat pipe diodes (HPDs), efficient thermal insulation and efficient miniature cryocoolers are used.

  16. Active noise canceling system for mechanically cooled germanium radiation detectors

    DOEpatents

    Nelson, Karl Einar; Burks, Morgan T

    2014-04-22

    A microphonics noise cancellation system and method for improving the energy resolution for mechanically cooled high-purity Germanium (HPGe) detector systems. A classical adaptive noise canceling digital processing system using an adaptive predictor is used in an MCA to attenuate the microphonics noise source making the system more deployable.

  17. Digital gamma-gamma coincidence HPGe system for environmental analysis.

    PubMed

    Marković, Nikola; Roos, Per; Nielsen, Sven Poul

    2017-08-01

    The performance of a new gamma-gamma coincidence spectrometer system for environmental samples analysis at the Center for Nuclear Technologies of the Technical University of Denmark (DTU) is reported. Nutech Coincidence Low Energy Germanium Sandwich (NUCLeGeS) system consists of two HPGe detectors in a surface laboratory with a digital acquisition system used to collect the data in time-stamped list mode with 10ns time resolution. The spectrometer is used in both anticoincidence and coincidence modes. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Calibration of a portable HPGe detector using MCNP code for the determination of 137Cs in soils.

    PubMed

    Gutiérrez-Villanueva, J L; Martín-Martín, A; Peña, V; Iniguez, M P; de Celis, B; de la Fuente, R

    2008-10-01

    In situ gamma spectrometry provides a fast method to determine (137)Cs inventories in soils. To improve the accuracy of the estimates, one can use not only the information on the photopeak count rates but also on the peak to forward-scatter ratios. Before applying this procedure to field measurements, a calibration including several experimental simulations must be carried out in the laboratory. In this paper it is shown that Monte Carlo methods are a valuable tool to minimize the number of experimental measurements needed for the calibration.

  19. A compact DD neutron generator-based NAA system to quantify manganese (Mn) in bone in vivo.

    PubMed

    Liu, Yingzi; Byrne, Patrick; Wang, Haoyu; Koltick, David; Zheng, Wei; Nie, Linda H

    2014-09-01

    A deuterium-deuterium (DD) neutron generator-based neutron activation analysis (NAA) system has been developed to quantify metals, including manganese (Mn), in bone in vivo. A DD neutron generator with a flux of up to 3*10(9) neutrons s(-1) was set up in our lab for this purpose. Optimized settings, including moderator, reflector, and shielding material and thickness, were selected based on Monte Carlo (MC) simulations conducted in our previous work. Hand phantoms doped with different Mn concentrations were irradiated using the optimized DD neutron generator irradiation system. The Mn characteristic γ-rays were collected by an HPGe detector system with 100% relative efficiency. The calibration line of the Mn/calcium (Ca) count ratio versus bone Mn concentration was obtained (R(2) = 0.99) using the hand phantoms. The detection limit (DL) was calculated to be about 1.05 μg g(-1) dry bone (ppm) with an equivalent dose of 85.4 mSv to the hand. The DL can be reduced to 0.74 ppm by using two 100% HPGe detectors. The whole body effective dose delivered to the irradiated subject was calculated to be about 17 μSv. Given the average normal bone Mn concentration of 1 ppm in the general population, this system is promising for in vivo bone Mn quantification in humans.

  20. Elemental analysis using natural gamma-ray spectroscopy

    NASA Astrophysics Data System (ADS)

    Aksoy, A.; Naqvi, A. A.; Khiari, F. Z.; Abujarad, F.; Al-Ohali, M.; Sumani, M.

    1994-12-01

    A gamma-ray spectroscopy setup has been recently established to measure the natural gamma-ray activity from potassium ( 40K), uranium ( 238U), and thorium ( 232Th) isotopes in rock samples of oil well-logs. The setup mainly consists of a shielded 135 cm 3 Hyper Pure Germanium (HPGe) detector, a 5 in. × 5 in. NaT(Tl) detector and a PC based data acquisition system. The core samples, with 70-100 g weight, have cylindrical geometry and are sealed such that radon gas from 238U decay would not escape from the sample. For room background subtraction, pure quartz samples identical to core samples were used. The sample is first counted with the HPGe detector to identify the elements through its characteristics gamma rays. Then the elemental concentration is determined by counting the sample with a NaI detector. In order to determine the absolute concentrations, the sample activity is compared with the activities of standards supplied by NIST and IAEA. The concentration of 238U and 232Th has been determined in ppm range with that of 40K in wt.%.

  1. X-ray spectroscopy of warm and hot electron components in the CAPRICE source plasma at EIS testbench at GSI.

    PubMed

    Mascali, D; Celona, L; Maimone, F; Maeder, J; Castro, G; Romano, F P; Musumarra, A; Altana, C; Caliri, C; Torrisi, G; Neri, L; Gammino, S; Tinschert, K; Spaedtke, K P; Rossbach, J; Lang, R; Ciavola, G

    2014-02-01

    An experimental campaign aiming to detect X radiation emitted by the plasma of the CAPRICE source - operating at GSI, Darmstadt - has been carried out. Two different detectors (a SDD - Silicon Drift Detector and a HpGe - hyper-pure Germanium detector) have been used to characterize the warm (2-30 keV) and hot (30-500 keV) electrons in the plasma, collecting the emission intensity and the energy spectra for different pumping wave frequencies and then correlating them with the CSD of the extracted beam measured by means of a bending magnet. A plasma emissivity model has been used to extract the plasma density along the cone of sight of the SDD and HpGe detectors, which have been placed beyond specific collimators developed on purpose. Results show that the tuning of the pumping frequency considerably modifies the plasma density especially in the warm electron population domain, which is the component responsible for ionization processes: a strong variation of the plasma density near axis region has been detected. Potential correlations with the charge state distribution in the plasma are explored.

  2. Applying a low energy HPGe detector gamma ray spectrometric technique for the evaluation of Pu/Am ratio in biological samples.

    PubMed

    Singh, I S; Mishra, Lokpati; Yadav, J R; Nadar, M Y; Rao, D D; Pradeepkumar, K S

    2015-10-01

    The estimation of Pu/(241)Am ratio in the biological samples is an important input for the assessment of internal dose received by the workers. The radiochemical separation of Pu isotopes and (241)Am in a sample followed by alpha spectrometry is a widely used technique for the determination of Pu/(241)Am ratio. However, this method is time consuming and many times quick estimation is required. In this work, Pu/(241)Am ratio in the biological sample was estimated with HPGe detector based measurements using gamma/X-rays emitted by these radionuclides. These results were compared with those obtained from alpha spectroscopy of sample after radiochemical analysis and found to be in good agreement. Copyright © 2015 Elsevier Ltd. All rights reserved.

  3. Multiagency Urban Search Experiment Detector and Algorithm Test Bed

    NASA Astrophysics Data System (ADS)

    Nicholson, Andrew D.; Garishvili, Irakli; Peplow, Douglas E.; Archer, Daniel E.; Ray, William R.; Swinney, Mathew W.; Willis, Michael J.; Davidson, Gregory G.; Cleveland, Steven L.; Patton, Bruce W.; Hornback, Donald E.; Peltz, James J.; McLean, M. S. Lance; Plionis, Alexander A.; Quiter, Brian J.; Bandstra, Mark S.

    2017-07-01

    In order to provide benchmark data sets for radiation detector and algorithm development, a particle transport test bed has been created using experimental data as model input and validation. A detailed radiation measurement campaign at the Combined Arms Collective Training Facility in Fort Indiantown Gap, PA (FTIG), USA, provides sample background radiation levels for a variety of materials present at the site (including cinder block, gravel, asphalt, and soil) using long dwell high-purity germanium (HPGe) measurements. In addition, detailed light detection and ranging data and ground-truth measurements inform model geometry. This paper describes the collected data and the application of these data to create background and injected source synthetic data for an arbitrary gamma-ray detection system using particle transport model detector response calculations and statistical sampling. In the methodology presented here, HPGe measurements inform model source terms while detector response calculations are validated via long dwell measurements using 2"×4"×16" NaI(Tl) detectors at a variety of measurement points. A collection of responses, along with sampling methods and interpolation, can be used to create data sets to gauge radiation detector and algorithm (including detection, identification, and localization) performance under a variety of scenarios. Data collected at the FTIG site are available for query, filtering, visualization, and download at muse.lbl.gov.

  4. TH-CD-201-02: A Monte Carlo Investigation of a Novel Detector Arrangement for the Energy Spectrum Measurement of a 6MV Linear Accelerator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Taneja, S; Bartol, L; Culberson, W

    2016-06-15

    Purpose: Direct measurement of the energy spectrum of a 6MV linear accelerator has not been successful due to the high fluence rate, high energy nature of these photon beams. Previous work used a Compton Scattering (CS) spectrometry setup with a shielded spectrometer for spectrum measurements. Despite substantial lead shielding, excessive pulse pile-up was seen. MCNP6 transport code was used to investigate the feasibility and effectiveness of performing measurements using a novel detector setup. Methods: Simulations were performed with a shielded high-purity germanium (HPGe) semiconductor detector placed in the accelerator vault’s maze, with a 2 cm diameter collimator through a 92more » cm thick concrete wall. The detector was positioned 660 cm from a scattering rod (placed at isocenter) at an angle of 45° relative to the central axis. This setup was compared with the shielded detector positioned in the room, 200 cm from the scattering rod at the same CS angle. Simulations were used to determine fluence contributions from three sources: (1) CS photons traveling through the collimator aperture, the intended signal, (2) CS scatter photons penetrating the detector shield, and (3) room-scattered photons penetrating the detector shield. Variance reduction techniques including weight windows, DXTRAN spheres, forced collisions, and energy cutoffs were used. Results: Simulations showed that the number of pulses per starting particle from an F8 detector tally for the intended signal decreased by a factor of 10{sup 2} when moving the detector out of the vault. This reduction in signal was amplified for the unwanted scatter signal which decreased by up to a factor of 10{sup 9}. Conclusion: This work used MCNP6 to show that using a vault wall to shield unwanted scatter and increasing isocenter-to-detector distance reduces unwanted fluence to the detector. This study aimed to provide motivation for future experimental work using the proposed setup.« less

  5. The MCNP Simulation of a PGNAA System at TRR-1/M1

    NASA Astrophysics Data System (ADS)

    Sangaroon, S.; Ratanatongchai, W.; Picha, R.; Khaweerat, S.; Channuie, J.

    2017-06-01

    The prompt-gamma neutron activation analysis system (PGNAA) has been installed at Thai Research Reactor-1/Modified 1 (TRR-1/M1) since 1999. The purpose of the system is for elemental and isotopic analyses. The system mainly consists of a series of the moderator and collimator, neutron and gamma-ray shielding and the HPGe detector. In this work, the condition of the system is carried out based on the Monte Carlo method using Monte Carlo N-Particle transport code and the experiment. The flux ratios (Φthermal/Φepithermal and Φthermal/Φfast) and thermal neutron flux have been obtained. The simulated prompt gamma rays of the Portland cement sample have been carried out. The simulation provides significant contribution in upgrading the PGNAA station to be available in various applications.

  6. Wilcoxon signed-rank-based technique for the pulse-shape analysis of HPGe detectors

    NASA Astrophysics Data System (ADS)

    Martín, S.; Quintana, B.; Barrientos, D.

    2016-07-01

    The characterization of the electric response of segmented-contact high-purity germanium detectors requires scanning systems capable of accurately associating each pulse with the position of the interaction that generated it. This process requires an algorithm sensitive to changes above the electronic noise in the pulse shapes produced at different positions, depending on the resolution of the Ge crystal. In this work, a pulse-shape comparison technique based on the Wilcoxon signed-rank test has been developed. It provides a method to distinguish pulses coming from different interaction points in the germanium crystal. Therefore, this technique is a necessary step for building a reliable pulse-shape database that can be used later for the determination of the position of interaction for γ-ray tracking spectrometry devices such as AGATA, GRETA or GERDA. The method was validated by comparison with a χ2 test using simulated and experimental pulses corresponding to a Broad Energy germanium detector (BEGe).

  7. A high-resolution gamma-ray and hard X-ray spectrometer for solar flare observations in Max 1991

    NASA Technical Reports Server (NTRS)

    Lin, R. P.; Curtis, D. W.; Harvey, P.; Hurley, K.; Primbsch, J. H.; Smith, D. M.; Pelling, R. M.; Duttweiler, F.

    1988-01-01

    A long duration balloon flight instrument for Max 1991 designed to study the acceleration of greater than 10 MeV ions and greater than 15 keV electrons in solar flares through high resolution spectroscopy of the gamma ray lines and hard X-ray and gamma ray continuum is described. The instrument, HIREGS, consists of an array of high-purity, n-type coaxial germanium detectors (HPGe) cooled to less than 90 K and surrounded by a bismuth germanate (BGO) anticoincidence shield. It will cover the energy range 15 keV to 20 MeV with keV spectral resolution, sufficient for accurate measurement of all parameters of the expected gamma ray lines with the exception of the neutron capture deuterium line. Electrical segmentation of the HPGe detector into a thin front segment and a thick rear segment, together with pulse-shape discrimination, provides optimal dynamic range and signal-to-background characteristics for flare measurements. Neutrons and gamma rays up to approximately 0.1 to 1 GeV can be detected and identified with the combination of the HPGe detectors and rear BGO shield. The HIREGS is planned for long duration balloon flights (LDBF) for solar flare studies during Max 1991. The two exploratory LDBFs carried out at mid-latitudes in 1987 to 1988 are described, and the LDBFs in Antarctica, which could in principle provide 24 hour/day solar coverage and very long flight durations (20 to 30 days) because of minimal ballast requirements are discussed.

  8. Material screening with HPGe counting station for PandaX experiment

    NASA Astrophysics Data System (ADS)

    Wang, X.; Chen, X.; Fu, C.; Ji, X.; Liu, X.; Mao, Y.; Wang, H.; Wang, S.; Xie, P.; Zhang, T.

    2016-12-01

    A gamma counting station based on high-purity germanium (HPGe) detector was set up for the material screening of the PandaX dark matter experiments in the China Jinping Underground Laboratory. Low background gamma rate of 2.6 counts/min within the energy range of 20 to 2700 keV is achieved due to the well-designed passive shield. The sentivities of the HPGe detetector reach mBq/kg level for isotopes like K, U, Th, and even better for Co and Cs, resulted from the low-background rate and the high relative detection efficiency of 175%. The structure and performance of the counting station are described in this article. Detailed counting results for the radioactivity in materials used by the PandaX dark-matter experiment are presented. The upgrading plan of the counting station is also discussed.

  9. X-ray spectroscopy of warm and hot electron components in the CAPRICE source plasma at EIS testbench at GSI

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mascali, D., E-mail: davidmascali@lns.infn.it; Celona, L.; Castro, G.

    2014-02-15

    An experimental campaign aiming to detect X radiation emitted by the plasma of the CAPRICE source – operating at GSI, Darmstadt – has been carried out. Two different detectors (a SDD – Silicon Drift Detector and a HpGe – hyper-pure Germanium detector) have been used to characterize the warm (2–30 keV) and hot (30–500 keV) electrons in the plasma, collecting the emission intensity and the energy spectra for different pumping wave frequencies and then correlating them with the CSD of the extracted beam measured by means of a bending magnet. A plasma emissivity model has been used to extract themore » plasma density along the cone of sight of the SDD and HpGe detectors, which have been placed beyond specific collimators developed on purpose. Results show that the tuning of the pumping frequency considerably modifies the plasma density especially in the warm electron population domain, which is the component responsible for ionization processes: a strong variation of the plasma density near axis region has been detected. Potential correlations with the charge state distribution in the plasma are explored.« less

  10. Measurement of the prompt fissionγ-ray spectrum of 242Pu

    NASA Astrophysics Data System (ADS)

    Urlass, Sebastian; Beyer, Roland; Junghans, Arnd Rudolf; Kögler, Toni; Schwengner, Ronald; Wagner, Andreas

    2018-03-01

    The prompt γ-ray spectrum of fission fragments is important in understanding the dynamics of the fission process, as well as for nuclear engineering in terms of predicting the γ-ray heating in nuclear reactors. The γ-ray spectrum measured from the fission fragments of the spontaneous fission of 242Pu will be presented here. A fission chamber containing in total 37mg of 242Pu was used as active sample. The γ-quanta were detected with high time- and energy-resolution using LaBr3 and HPGe detectors, respectively, in coincidence with spontaneous fission events detected by the fission chamber. The acquired γ-ray spectra were corrected for the detector response using the spectrum stripping method. About 70 million fission events were detected which results in a very low statistical uncertainty and a wider energy range covered compared to previous measurements. The prompt fission γ-ray spectrum measured with the HPGe detectors shows structures that allow conclusions about the nature of γ-ray transitions in the fission fragments. The average photon multiplicity of 8.2 and the average total energy release by prompt photons per fission event of about 6.8 MeV were determined for both detector types.

  11. Novel HPGe Probe solution for Harsh Environments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Clauss, J.; Pirard, B.; Menaa, N.

    2015-07-01

    In situ measurement is a privileged way of monitoring radioactive contamination compared to analyzing samples in a distant, specialized laboratory. Scintillators based spectrometers offer small footprints and are easy to easy to use, however they do not provide an accurate nuclide identification capability and activities measurement because notably of their limited energy resolution, for instance when low minimum detectable activity (MDA) are required, or in complex mixture of sources. On the other hand, High Purity Germanium (HPGe) detectors provide unmatched nuclide identification capability with the lowest MDA but they are not always of practical use on the field because themore » crystal needs to be cooled down to liquid nitrogen temperature, increasing the overall weight, bulkiness and complexity of the measurement. This paper presents the configuration and performance of a novel turnkey and compact HPGe solution developed by Canberra for radionuclide identification under harsh environments. Radio-contaminations surveys now can be undertaken outdoor under various weather conditions, in contaminated areas, underground or underwater locations (including under sea water), with fast on site deployment. The spectrometer is also designed in a small diameter tubular shape to offer minimal footprint for an operation in narrow and confined spaces. Besides, this innovative design does not mitigate the performances nor the reliability experienced with standard laboratory-grade HPGe spectrometers. This achievement relies on advanced technologies such as the encapsulation of the crystal in ultra-high vacuum (UHV) which provides higher robustness and does not requires thermal cycles faced with regular HPGe equipment. It also relies on a low vibration, low consumption electrical cooler so that no liquid nitrogen is being used. The detector is connected to a state-of-the-art digital spectroscopy suite embedded in an autonomous acquisition station monitoring the cryo-cooler and including the spectroscopy software. This system presented is therefore a new solution to perform high resolution spectroscopy where no current products are compact or robust enough to be installed, for instance for soil and water decontamination measurement when anthropogenic radioactive sources must be identified from natural ones or when low contamination levels are expected, the MDA being 3 to 5 times higher than scintillator-based detectors of similar sizes. Environmental inspection such as well logging for geophysics and mining, water contamination monitoring, or decommissioning works can thus benefits from both ruggedness, mobility without compromise on the nuclide identification or activity measurement capability. (authors)« less

  12. Long-term assessment of contaminated articles from the Chernobyl reactor.

    PubMed

    Alkhomashi, N; Monged, M H E

    2015-06-01

    The Chernobyl accident caused a release of radioactive materials from the reactor into the environment. This event contaminated people, their surroundings and their personal property, especially in the zone around the reactor. Among the affected individuals were British students who were studying in Minsk and Kiev at the time of the Chernobyl accident. These students were exposed to external and internal radiation, and the individuals' articles of clothing were contaminated. The primary objective of this study was to analyze a sample of this contaminated clothing 20 years after the accident using three different detectors, namely, a BP4/4C scintillation detector, a Min-Con Geiger-Müller tube detector and a high-purity germanium (HPGe) detector. The clothing articles were initially assessed and found not to be significantly contaminated. However, there were several hot spots of contamination in various regions of the articles. The net count rates for these hot spots were in the range of 10.00 ± 3.16 c/s to 41.00 ± 6.40 c/s when the BP4/4C scintillation detector was used. The HPGe detector was used to identify the radionuclides present in the clothing, and the results indicated that the only active radionuclide was (137)Cs because of this isotope's long half-life. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. Digital pulse-shape analysis with a TRACE early silicon prototype

    NASA Astrophysics Data System (ADS)

    Mengoni, D.; Dueñas, J. A.; Assié, M.; Boiano, C.; John, P. R.; Aliaga, R. J.; Beaumel, D.; Capra, S.; Gadea, A.; Gonzáles, V.; Gottardo, A.; Grassi, L.; Herrero-Bosch, V.; Houdy, T.; Martel, I.; Parkar, V. V.; Perez-Vidal, R.; Pullia, A.; Sanchis, E.; Triossi, A.; Valiente Dobón, J. J.

    2014-11-01

    A highly segmented silicon-pad detector prototype has been tested to explore the performance of the digital pulse shape analysis in the discrimination of the particles reaching the silicon detector. For the first time a 200 μm thin silicon detector, grown using an ordinary floating zone technique, has been shown to exhibit a level discrimination thanks to the fine segmentation. Light-charged particles down to few MeV have been separated, including their punch-through. A coaxial HPGe detector in time coincidence has further confirmed the quality of the particle discrimination.

  14. The ROSPHERE γ-ray spectroscopy array

    NASA Astrophysics Data System (ADS)

    Bucurescu, D.; Căta-Danil, I.; Ciocan, G.; Costache, C.; Deleanu, D.; Dima, R.; Filipescu, D.; Florea, N.; Ghiţă, D. G.; Glodariu, T.; Ivaşcu, M.; Lică, R.; Mărginean, N.; Mărginean, R.; Mihai, C.; Negret, A.; Niţă, C. R.; Olăcel, A.; Pascu, S.; Sava, T.; Stroe, L.; Şerban, A.; Şuvăilă, R.; Toma, S.; Zamfir, N. V.; Căta-Danil, G.; Gheorghe, I.; Mitu, I. O.; Suliman, G.; Ur, C. A.; Braunroth, T.; Dewald, A.; Fransen, C.; Bruce, A. M.; Podolyák, Zs.; Regan, P. H.; Roberts, O. J.

    2016-11-01

    The ROmanian array for SPectroscopy in HEavy ion REactions (ROSPHERE) has been designed as a multi-detector setup dedicated to γ-ray spectroscopy studies at the Bucharest 9 MV Tandem accelerator. Consisting of up to 25 detectors (either Compton suppressed HPGe detectors or fast LaBr3(Ce) scintillator detectors) together with a state of the art plunger device, ROSPHERE is a powerful tool for lifetime measurements using the Recoil Distance Doppler Shift (RDDS) and the in-beam Fast Electronic Scintillation Timing (FEST) methods. The array's geometry, detectors, electronics and data acquisition system are described. Selected results from the first experimental campaigns are also presented.

  15. Search for double beta processes in {sup 106}Cd with enriched {sup 106}CdWO{sub 4} crystal scintillator in coincidence with four crystals HPGe detector

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Danevich, F. A., E-mail: danevich@kinr.kiev.ua; Chernyak, D. M.; Mokina, V. M.

    2015-10-28

    A radiopure cadmium tungstate crystal scintillator, enriched in {sup 106}Cd ({sup 106}CdWO{sub 4}), was used to search for double beta decay processes in {sup 106}Cd in coincidence with an ultra-low background set-up containing four high purity germanium (HPGe) detectors in a single cryostat. The experiment has been completed after 13085 h of data taking. New improved limits on most of the double beta processes in {sup 106}Cd have been set on the level of 10{sup 20}−10{sup 21} yr. Tn particular, the half-life limit on the two neutrino electron capture with positron emission, T{sub 1/2} ≥ 1.8 × 10{sup 21} yr, reachedmore » the region of theoretical predictions.« less

  16. Development of cryogenic CMOS Readout ASICs for the Point-Contact HPGe Detectors for Dark Matter Search and Neutrino Experiments

    NASA Astrophysics Data System (ADS)

    Deng, Zhi; He, Li; Liu, Feng; Liu, Yinong; Xue, Tao; Li, Yulan; Yue, Qian

    2017-05-01

    The paper presents the developments of two cryogenic readout ASICs for the point-contact HPGe detectors for dark matter search and neutrino experiments. Extremely low noise readout electronics were demanded and the capability of working at cryogenic temperatures may bring great advantages. The first ASIC was a monolithic CMOS charge sensitive preamplifier with its noise optimized for ∼1 pF input capacitance. The second ASIC was a waveform recorder based on switched capacitor array. These two ASICs were fabricated in CMOS 350 nm and 180 nm processes respectively. The prototype chips were tested and showed promising results. Both ASICs worked well at low temperature. The preamplifier had achieved ENC of 10.3 electrons with 0.7 pF input capacitance and the SCA chip could run at 9 bit effective resolution and 25 MSPS sampling rate.

  17. High resolution gamma-ray spectroscopy at high count rates with a prototype High Purity Germanium detector

    NASA Astrophysics Data System (ADS)

    Cooper, R. J.; Amman, M.; Vetter, K.

    2018-04-01

    High-resolution gamma-ray spectrometers are required for applications in nuclear safeguards, emergency response, and fundamental nuclear physics. To overcome one of the shortcomings of conventional High Purity Germanium (HPGe) detectors, we have developed a prototype device capable of achieving high event throughput and high energy resolution at very high count rates. This device, the design of which we have previously reported on, features a planar HPGe crystal with a reduced-capacitance strip electrode geometry. This design is intended to provide good energy resolution at the short shaping or digital filter times that are required for high rate operation and which are enabled by the fast charge collection afforded by the planar geometry crystal. In this work, we report on the initial performance of the system at count rates up to and including two million counts per second.

  18. Direct and precise determination of environmental radionuclides in solid materials using a modified Marinelli beaker and a HPGe detector.

    PubMed

    Seo, B K; Lee, K Y; Yoon, Y Y; Lee, D W

    2001-06-01

    A simple but precise detection method was studied for the determination of natural radionuclides using a conventional HPGe detector. A new aluminium beaker instead of a plastic Marinelli beaker was constructed and examined to reach radioactive equilibrium conditions between radon and its daughter elements without the escape of gaseous radon. Using this beaker fifteen natural radionuclides from three natural decay series could be determined by direct gamma-ray measurement and sixteen radionuclides could be determined indirectly after radioactive equilibrium had been reached. Analytical results from ground water were compared with those from conventional alpha spectroscopy and the results agreed well within 12% difference. Nitrogen gas purge was used to replace the surrounding air of the detector to obtain a stable background and reducing the interference of radon daughter nuclides in the atmosphere. The use of nitrogen purging and the aluminium Marinelli beaker results in an approximately tenfold increase of sensitivity and a decrease of the detection limit of 226Ra to about 0.74 Bq kg(-1) in soil samples.

  19. Neutron-Induced Partial Cross-Section Measurements on ^76Ge Motivated by The Majorana Project 0νββ Decay Search

    NASA Astrophysics Data System (ADS)

    Hilderbrand, S.; Kwan, E.; Angell, C.; Fallin, B.; Howell, C. R.; Hutcheson, A.; Karwowski, H. J.; Kelley, J. H.; Tonchev, A. P.; Tornow, W.; Masters, D. B.; Pedroni, R. S.; Weisel, G. J.

    2007-10-01

    The goal of the Majorana Collaboration is to study 0νββ in order to verify that the neutrino is its own anti-particle; and if so, what is the mass ofthe electron neutrino. Observation of a sharp peak at the ββ endpoint energy will confirm 0νββ as a decay mode, and determination of the partial width will determine the matrix element which depends directly on the electron neutrino mass. In order to observe and verify the existence of 0νββ, it is important to reduce intrinsic, extrinsic,& cosmogenic backgrounds. The Majorana Project will operate with HPGe detectors deep underground to achieve a low-background environment. Recent advances in signal processing and detector design have also enabled scientists to further understand background sources. γ-ray spectra from the interaction of pulsed mono-energetic neutrons with ^76Ge were measured at TUNL using segmented HPGe clover detectors. The neutron-induced partial cross-sections for γ transitions in ^76Ge were measured at En = 8 and 12MeV.

  20. Status of the MAJORANA DEMONSTRATOR

    NASA Astrophysics Data System (ADS)

    Vasilyev, S.; Abgrall, N.; Arnquist, I. J.; Avignone, F. T.; Balderrot-Barrera, C. X.; Barabash, A. S.; Bertrand, F. E.; Bradley, A. W.; Brudanin, V.; Busch, M.; Buuck, M.; Byram, D.; Caldwell, A. S.; Chan, Y.-D.; Christofferson, C. D.; Cuesta, C.; Detwiler, J. A.; Efremenko, Yu.; Ejiri, H.; Elliott, S. R.; Galindo-Uribarri, A.; Gilliss, T.; Giovanetti, G. K.; Goett, J.; Green, M. P.; Gruszko, J.; Guinn, I.; Guiseppe, V. E.; Henning, R.; Hoppe, E. W.; Howard, S.; Howe, M. A.; Jasinski, B. R.; Keeter, K. E.; Kidd, M. F.; Konovalov, S. I.; Kouzes, R. T.; LaFerriere, B. D.; Leon, J.; MacMullin, J.; Martin, R. D.; Meijer, S. J.; Mertens, S.; Orrell, J. L.; O'Shaughnessy, C.; Poon, A. W. P.; Radford, D. C.; Rager, J.; Rielage, K.; Robertson, R. G. H.; Romero-Romero, E.; Shanks, B.; Shirchenko, M.; Snyder, N.; Suriano, A. M.; Tedeschi, D.; Trimble, J. E.; Varner, R. L.; Vetter, K.; Vorren, K.; White, B. R.; Wilkerson, J. F.; Wiseman, C.; Xu, W.; Yakushev, E.; Yu, C.-H.; Yumatov, V.; Zhitnikov, I.

    2017-01-01

    The MAJORANA Collaboration is constructing the MAJORANA DEMONSTRATOR, an ultralow background, 40-kg modular high purity Ge (HPGe) detector array to search for neutrinoless double-beta decay (0νββ-decay) in 76Ge. The goal of the experiment is to demonstrate a background rate at or below 3 counts/(t-y) in the 4 keV region of interest (ROI) around the 2039 keV Q-value for 76Ge 0νββ-decay. In this paper, the status of the MAJORANA DEMONSTRATOR, including its design and measurements of properties of the HPGe crystals is presented.

  1. Spatially-resolved HPGe Gamma-ray Spectroscopy of Swipe Samples

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McDonald, Benjamin S.; VanDevender, Brent A.; Wood, Lynn S.

    Measurement of swipe samples is a critical element of the National Technical Nuclear Forensics (NTNF) mission. A unique, portable, germanium gamma imager (GeGI-s) from PHDS Co may provide complementary information to current techniques for swipe sample screening. The GeGI-s is a modified version of the commercial GeGI-4, a planar HPGe detector, capable of several million counts per second across the whole detector. The GeGI-s detector is a prototype of a commercial off-the-shelf high rate GeGI. The high rate capability allows high-activity samples be placed directly on the face of the detector. Utilizing the high energy resolution and pixelization of themore » detector, the GeGI-s can generate isotope specific spatial maps of the materials on the swipe sample. To prove this technology is viable for such mapping, the GeGI-s detector response to spatially distributed events must be well characterized. The detection efficiency as a function of location has been characterized to understand the non-uniformities presented as a collimated photon beam was rastered vertically and horizontally across the face of the detector. The detection efficiency as a function of location has been characterized to understand the non-uniformities presented as a collimated photon beam was rastered vertically and horizontally across the face of the detector. The response was found to be primarily uniform and symmetric, however two causes of non-uniformity were found. Both of these causes can ultimately be corrected for in off-line data analysis.« less

  2. Electronic catalogue of muonic X-rays

    NASA Astrophysics Data System (ADS)

    Zinatulina, Daniya; Briançon, Chantal; Brudanin, Victor; Egorov, Viacheslav; Perevoshchikov, Lev; Shirchenko, Mark; Yutlandov, Igor; Petitjean, Claude

    2018-04-01

    μX-ray spectra for Z=9-90 were measured with HPGe detectors and muonic beams of PSI (Villigen, Switzerland) [1]. The results are presented as electronic atlas composed of graphic plots. The atlas is available at JINR site [2].

  3. Performance of A Compact Multi-crystal High-purity Germanium Detector Array for Measuring Coincident Gamma-ray Emissions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Howard, Chris; Daigle, Stephen; Buckner, Matt

    2015-02-18

    The Multi-sensor Airborne Radiation Survey (MARS) detector is a 14-crystal array of high-purity germanium (HPGe) detectors housed in a single cryostat. The array was used to measure the astrophysical S-factor for the 14N(p,γ) 15O* reaction for several transition energies at an effective center of mass energy of 163 keV. Owing to the segmented nature of the MARS detector, the effect of gamma-ray summing was greatly reduced in comparison to past experiments which utilized large, single-crystal detectors. The new S-factor values agree within the uncertainties with the past measurements. Details of the analysis and detector performance will be presented.

  4. A novel approach for predicting the response of the spectrometer for INTEGRAL satellite.

    PubMed

    Kshetri, R

    2013-05-01

    A basic phenomenological approach has been presented in three recent papers (Kshetri R., 2012. JINST 7, P04008; Kshetri R., 2012. JINST 7, P07006; Kshetri R., 2012. JINST 7, P12007) for understanding the operation of encapsulated type composite detectors including the SPI spectrometer. In the present paper, we have considered the fact that the experimental two-fold events between two detectors include the three and higher fold events between the same two detectors. The formalism has been further developed and the peak-to-total ratio of a general composite detector are predicted for energy region with no direct experimental information about them. At 8MeV, the peak-to-total ratio for the SPI spectrometer and a very large detector (comprising of infinite number of single HPGe modules) are found to be 9% and 12%, respectively. The predictions for fold distribution of the SPI spectrometer are found to be in agreement with experimental data. Our formulation does not include ad-hoc fits, but expressions that are justifiable by probability flow arguments. Instead of using an empirical method or simulation, we present a novel approach for calculating the peak-to-total ratio of the SPI spectrometer for high gamma energies. Copyright © 2013 Elsevier Ltd. All rights reserved.

  5. TIGRESS: TRIUMF-ISAC gamma-ray escape-suppressed spectrometer

    NASA Astrophysics Data System (ADS)

    Svensson, C. E.; Amaudruz, P.; Andreoiu, C.; Andreyev, A.; Austin, R. A. E.; Ball, G. C.; Bandyopadhyay, D.; Boston, A. J.; Chakrawarthy, R. S.; Chen, A. A.; Churchman, R.; Drake, T. E.; Finlay, P.; Garrett, P. E.; Grinyer, G. F.; Hackman, G.; Hyland, B.; Jones, B.; Kanungo, R.; Maharaj, R.; Martin, J. P.; Morris, D.; Morton, A. C.; Pearson, C. J.; Phillips, A. A.; Ressler, J. J.; Roy, R.; Sarazin, F.; Schumaker, M. A.; Scraggs, H. C.; Smith, M. B.; Starinsky, N.; Valiente-Dobón, J. J.; Waddington, J. C.; Watters, L. M.

    2005-10-01

    The TRIUMF-ISAC gamma-ray escape-suppressed spectrometer (TIGRESS) is a new γ-ray detector array being developed for use at TRIUMF's Isotope Separator and Accelerator (ISAC) radioactive ion beam facility. TIGRESS will comprise 12 32-fold segmented clover-type HPGe detectors coupled with 20-fold segmented modular Compton suppression shields and custom digital signal processing electronics. This paper provides an overview of the TIGRESS project and progress in its development to date.

  6. The Gerda search for neutrinoless double beta decay

    NASA Astrophysics Data System (ADS)

    O'Shaughnessy, Christopher; Gerda Collaboration

    2013-10-01

    The Germanium Detector Array (Gerda) is a search for the neutrinoless double beta decay of 76Ge. High Purity Germanium (HPGe) detectors enriched in the isotope-76 are operated bare in liquid argon (LAr). LAr is used for both cooling of the HPGe diodes to their operating temperatures and for shielding from external radiation sources. From the measurements of the first phase that began data taking on 1 Nov. 2011 it is expected to have a sensitivity on the level of T1/2>2E25 yr at a 90% CL after 15 kġyr. The goal of this phase will be to probe the claim of an observation by part of the Heidelberg-Moscow collaboration. Efforts will then focus on increasing the sensitivity of the experiment by deploying additional enriched detectors that are in an advanced stage of production and by reducing the background index further by making use of pulse shape discrimination techniques as well as an active LAr veto. While the 0νββ region of interest continues to remain blinded, here the status of Phase-I data taking is presented along with the work towards improving the experimental sensitivity.

  7. Design of an explosive detection system using Monte Carlo method.

    PubMed

    Hernández-Adame, Pablo Luis; Medina-Castro, Diego; Rodriguez-Ibarra, Johanna Lizbeth; Salas-Luevano, Miguel Angel; Vega-Carrillo, Hector Rene

    2016-11-01

    Regardless the motivation terrorism is the most important risk for the national security in many countries. Attacks with explosives are the most common method used by terrorists. Therefore several procedures to detect explosives are utilized; among these methods are the use of neutrons and photons. In this study the Monte Carlo method an explosive detection system using a 241 AmBe neutron source was designed. In the design light water, paraffin, polyethylene, and graphite were used as moderators. In the work the explosive RDX was used and the induced gamma rays due to neutron capture in the explosive was estimated using NaI(Tl) and HPGe detectors. When light water is used as moderator and HPGe as the detector the system has the best performance allowing distinguishing between the explosive and urea. For the final design the Ambient dose equivalent for neutrons and photons were estimated along the radial and axial axis. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. Analytical response function for planar Ge detectors

    NASA Astrophysics Data System (ADS)

    García-Alvarez, Juan A.; Maidana, Nora L.; Vanin, Vito R.; Fernández-Varea, José M.

    2016-04-01

    We model the response function (RF) of planar HPGe x-ray spectrometers for photon energies between around 10 keV and 100 keV. The RF is based on the proposal of Seltzer [1981. Nucl. Instrum. Methods 188, 133-151] and takes into account the full-energy absorption in the Ge active volume, the escape of Ge Kα and Kβ x-rays and the escape of photons after one Compton interaction. The relativistic impulse approximation is employed instead of the Klein-Nishina formula to describe incoherent photon scattering in the Ge crystal. We also incorporate a simple model for the continuous component of the spectrum produced by the escape of photo-electrons from the active volume. In our calculations we include external interaction contributions to the RF: (i) the incoherent scattering effects caused by the detector's Be window and (ii) the spectrum produced by photo-electrons emitted in the Ge dead layer that reach the active volume. The analytical RF model is compared with pulse-height spectra simulated using the PENELOPE Monte Carlo code.

  9. Characterization of naturally occurring radioactive materials in Libyan oil pipe scale using a germanium detector and Monte Carlo simulation

    NASA Astrophysics Data System (ADS)

    Habib, A. S.; Shutt, A. L.; Regan, P. H.; Matthews, M. C.; Alsulaiti, H.; Bradley, D. A.

    2014-02-01

    Radioactive scale formation in various oil production facilities is acknowledged to pose a potential significant health and environmental issue. The presence of such an issue in Libyan oil fields was recognized as early as 1998. The naturally occurring radioactive materials (NORM) involved in this matter are radium isotopes (226Ra and 228Ra) and their decay products, precipitating into scales formed on the surfaces of production equipment. A field trip to a number of onshore Libyan oil fields has indicated the existence of elevated levels of specific activity in a number of locations in some of the more mature oil fields. In this study, oil scale samples collected from different parts of Libya have been characterized using gamma spectroscopy through use of a well shielded HPGe spectrometer. To avoid potential alpha-bearing dust inhalation and in accord with safe working practices at this University, the samples, contained in plastic bags and existing in different geometries, are not permitted to be opened. MCNP, a Monte Carlo simulation code, is being used to simulate the spectrometer and the scale samples in order to obtain the system absolute efficiency and then to calculate sample specific activities. The samples are assumed to have uniform densities and homogeneously distributed activity. Present results are compared to two extreme situations that were assumed in a previous study: (i) with the entire activity concentrated at a point on the sample surface proximal to the detector, simulating the sample lowest activity, and; (ii) with the entire activity concentrated at a point on the sample surface distal to the detector, simulating the sample highest activity.

  10. A feasibility and optimization study to determine cooling time and burnup of advanced test reactor fuels using a nondestructive technique

    NASA Astrophysics Data System (ADS)

    Navarro, Jorge

    The goal of this study presented is to determine the best available nondestructive technique necessary to collect validation data as well as to determine burnup and cooling time of the fuel elements on-site at the Advanced Test Reactor (ATR) canal. This study makes a recommendation of the viability of implementing a permanent fuel scanning system at the ATR canal and leads to the full design of a permanent fuel scan system. The study consisted at first in determining if it was possible and which equipment was necessary to collect useful spectra from ATR fuel elements at the canal adjacent to the reactor. Once it was establish that useful spectra can be obtained at the ATR canal, the next step was to determine which detector and which configuration was better suited to predict burnup and cooling time of fuel elements nondestructively. Three different detectors of High Purity Germanium (HPGe), Lanthanum Bromide (LaBr3), and High Pressure Xenon (HPXe) in two system configurations of above and below the water pool were used during the study. The data collected and analyzed were used to create burnup and cooling time calibration prediction curves for ATR fuel. The next stage of the study was to determine which of the three detectors tested was better suited for the permanent system. From spectra taken and the calibration curves obtained, it was determined that although the HPGe detector yielded better results, a detector that could better withstand the harsh environment of the ATR canal was needed. The in-situ nature of the measurements required a rugged fuel scanning system, low in maintenance and easy to control system. Based on the ATR canal feasibility measurements and calibration results, it was determined that the LaBr3 detector was the best alternative for canal in-situ measurements; however, in order to enhance the quality of the spectra collected using this scintillator, a deconvolution method was developed. Following the development of the deconvolution method for ATR applications, the technique was tested using one-isotope, multi-isotope, and fuel simulated sources. Burnup calibrations were perfomed using convoluted and deconvoluted data. The calibrations results showed burnup prediction by this method improves using deconvolution. The final stage of the deconvolution method development was to perform an irradiation experiment in order to create a surrogate fuel source to test the deconvolution method using experimental data. A conceptual design of the fuel scan system is path forward using the rugged LaBr 3 detector in an above the water configuration and deconvolution algorithms.

  11. A Monte Carlo Simulation of the in vivo measurement of lung activity in the Lawrence Livermore National Laboratory torso phantom.

    PubMed

    Acha, Robert; Brey, Richard; Capello, Kevin

    2013-02-01

    A torso phantom was developed by the Lawrence Livermore National Laboratory (LLNL) that serves as a standard for intercomparison and intercalibration of detector systems used to measure low-energy photons from radionuclides, such as americium deposited in the lungs. DICOM images of the second-generation Human Monitoring Laboratory-Lawrence Livermore National Laboratory (HML-LLNL) torso phantom were segmented and converted into three-dimensional (3D) voxel phantoms to simulate the response of high purity germanium (HPGe) detector systems, as found in the HML new lung counter using a Monte Carlo technique. The photon energies of interest in this study were 17.5, 26.4, 45.4, 59.5, 122, 244, and 344 keV. The detection efficiencies at these photon energies were predicted for different chest wall thicknesses (1.49 to 6.35 cm) and compared to measured values obtained with lungs containing (241)Am (34.8 kBq) and (152)Eu (10.4 kBq). It was observed that no statistically significant differences exist at the 95% confidence level between the mean values of simulated and measured detection efficiencies. Comparisons between the simulated and measured detection efficiencies reveal a variation of 20% at 17.5 keV and 1% at 59.5 keV. It was found that small changes in the formulation of the tissue substitute material caused no significant change in the outcome of Monte Carlo simulations.

  12. The γ-ray angular distribution in fast neutron inelastic scattering from iron

    NASA Astrophysics Data System (ADS)

    Beyer, Roland; Dietz, Mirco; Bemmerer, Daniel; Junghans, Arnd R.; Kögler, Toni; Massarczyk, Ralph; Müller, Stefan; Schmidt, Konrad; Schwengner, Ronald; Szücs, Tamás; Takács, Marcell P.; Wagner, Andreas

    2018-04-01

    The angular distribution of γ-rays emitted after inelastic scattering of fast neutrons from iron was determined at the n ELBE neutron time-of-flight facility. An iron sample of natural isotopic composition was irradiated by a continuous photo-neutron spectrum in the energy range from about 0.1 up to 10 MeV. The de-excitation γ-rays of the four lowest excited states of 56Fe and the first excited state of 54Fe were detected using a setup of five high-purity germanium (HPGe) detectors and five LaBr3 scintillation detectors positioned around the sample at 30°, 55°, 90°, 125° and 150° with respect to the incoming neutron beam. The resulting angular distributions were fitted by Legendre polynomials up to 4th order and the angular distribution coefficients a2 and a4 were extracted. The angular distribution coefficients of three transitions in 56Fe are reported here for the first time. The results are applied to a previous measurement of the inelastic scattering cross section determined using a single HPGe detector positioned at 125°. Using the updated γ-ray angular distribution, the previous cross section results are in good agreement with reference data.

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gilbert, Andrew J.; Fast, James E.; Fulsom, Bryan G.

    For many nuclear material safeguards inspections, spectroscopic gamma detectors are required which can achieve high event rates (in excess of 10^6 s^-1) while maintaining very good energy resolution for discrimination of neighboring gamma signatures in complex backgrounds. Such spectra can be useful for non-destructive assay (NDA) of spent nuclear fuel with long cooling times, which contains many potentially useful low-rate gamma lines, e.g., Cs-134, in the presence of a few dominating gamma lines, such as Cs-137. Detectors in use typically sacrifice energy resolution for count rate, e.g., LaBr3, or visa versa, e.g., CdZnTe. In contrast, we anticipate that beginning withmore » a detector with high energy resolution, e.g., high-purity germanium (HPGe), and adapting the data acquisition for high throughput will be able to achieve the goals of the ideal detector. In this work, we present quantification of Cs-134 and Cs-137 activities, useful for fuel burn-up quantification, in fuel that has been cooling for 22.3 years. A segmented, planar HPGe detector is used for this inspection, which has been adapted for a high-rate throughput in excess of 500k counts/s. Using a very-high-statistic spectrum of 2.4*10^11 counts, isotope activities can be determined with very low statistical uncertainty. However, it is determined that systematic uncertainties dominate in such a data set, e.g., the uncertainty in the pulse line shape. This spectrum offers a unique opportunity to quantify this uncertainty and subsequently determine required counting times for given precision on values of interest.« less

  14. Gamma-ray mirror technology for NDA of spent fuel

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Descalle, M. A.; Ruz-Armendariz, J.; Decker, T.

    Direct measurements of gamma rays emitted by fissile material have been proposed as an alternative to measurements of the gamma rays from fission products. From a safeguards applications perspective, direct detection of uranium (U) and plutonium (Pu) K-shell fluorescence emission lines and specific lines from some of their isotopes could lead to improved shipper-receiver difference or input accountability at the start of Pu reprocessing. However, these measurements are difficult to implement when the spent fuel is in the line-of-sight of the detector, as the detector is exposed to high rates dominated by fission product emissions. To overcome the combination ofmore » high rates and high background, grazing incidence multilayer mirrors have been proposed as a solution to selectively reflect U and Pu hard X-ray and soft gamma rays in the 90 to 420 keV energy into a high-purity germanium (HPGe) detector shielded from the direct line-of-sight of spent fuel. Several groups demonstrated that K-shell fluorescence lines of U and Pu in spent fuel could be detected with Ge detectors. In the field of hard X-ray optics the performance of reflective multilayer coated reflective optics was demonstrated up to 645 keV at the European Synchrotron Radiation Facility. Initial measurements conducted at Oak Ridge National Laboratory with sealed sources and scoping experiments conducted at the ORNL Irradiated Fuels Examination Laboratory (IFEL) with spent nuclear fuel further demonstrated the pass-band properties of multilayer mirrors for reflecting specific emission lines into 1D and 2D HPGe detectors, respectively.« less

  15. Inelastic neutron scattering with GAINS at GELINA: An overview of the last decade

    NASA Astrophysics Data System (ADS)

    Borcea, Catalin; Dessagne, Philippe; Kerveno, Maëlle; Mihailescu, Cristian; Nankov, Nikolay; Negret, Alexandru; Nyman, Markus; Olacel, Adina; Oláh, Laszlo; Plompen, Arjan; Rouki, Chariklia; Rudolf, Gerard

    2017-09-01

    GAINS is an array of HPGe detectors installed at the GELINA neutron source of Joint Research Center, Geel, Belgium. It served to measure the cross section for (n,n'γ) reactions on many isotopes. The paper presents the experimental setup and reviews the main results obtained in the last decade

  16. Partial Cross Sections of Neutron-Induced Reactions on nCu at En = 6, 8, 10, 12, 14, and 16 MeV for 0νββ Background Studies

    NASA Astrophysics Data System (ADS)

    Gooden, M. E.; Fallin, B. A.; Finch, S. W.; Kelley, J. H.; Howell, C. R.; Rusev, G.; Tonchev, A. P.; Tornow, W.; Stanislav, V.

    2014-05-01

    Partial cross-section measurements of (n,n'γ) reactions on natCu were carried out at TUNL using monoenergetic neutrons at six energies of En = 6, 8, 10, 12, 14, 16 MeV. These studies were performed to provide accurate cross-section data on materials abundant in experimental setups involving HPGe detectors used to search for rare events, like the neutrino-less double-beta decay of 76Ge. Spallation and (α,n) neutrons are expected to cause the largest source of external background in the energy region of interest. At TUNL pulsed neutron beams were produced via the 2H(d,n)3He reaction and the deexcitation γ rays from the reaction natCu(n,xγ) were detected with clover HPGe detectors. Cross-section results for the strongest transtions in 63Cu and 65Cu will be reported, and will compared to model calculations and to data recently obtained at LANL with a white neutron beam.

  17. Nanosecond lifetime measurements of Iπ=9/2- intrinsic excited states and low-lying B(E1) strengths in 183Re using combined HPGe-LaBr3 coincidence spectroscopy

    NASA Astrophysics Data System (ADS)

    Gurgi, L. A.; Regan, P. H.; Daniel, T.; Podolyák, Zs.; Bruce, A. M.; Mason, P. J. R.; Mǎrginean, N.; Mǎrginean, R.; Werner, V.; Alharbi, T.; Alkhomashi, N.; Bajoga, A. D.; Britton, R.; Cǎta-Danil, I.; Carroll, R. J.; Deleanu, D.; Bucurescu, D.; Florea, N.; Gheorghe, I.; Ghita, D. G.; Glodariu, T.; Lice, R.; Mihai, C.; Mulholland, K. F.; Negret, A.; Olacel, A.; Roberts, O. J.; Sava, T.; Söderström, P.-A.; Stroe, L.; Suvaila, R.; Toma, S.; Wilson, E.; Wood, R. T.

    2017-08-01

    This paper presents precision measurements of electromagnetic decay probabilities associated with electric dipole transitions in the prolate-deformed nucleus 183Re. The nucleus of interest was formed using the fusion evaporation reaction 180Hf(7Li,4n)183Re at a beam energy of 30 MeV at the tandem accelerator at the HH-IFIN Institute, Bucharest Romania. Coincident decay gamma rays from near-yrast cascades were detected using the combined HPGe-LaBr3 detector array ROSPHERE. The time differences between cascade gamma rays were measured using the LaBr3 detectors to determine the half-lives of the two lowest lying spin-parity 9/2- states at excitation energies of 496 and 617 keV to be 5.65(5) and 2.08(3) ns respectively. The deduced E1 transition rates from these two states are discussed in terms of the K-hindrance between the low-lying structures in this prolate-deformed nucleus.

  18. Half-life of the superallowed β+ emitter Ne18

    NASA Astrophysics Data System (ADS)

    Grinyer, G. F.; Smith, M. B.; Andreoiu, C.; Andreyev, A. N.; Ball, G. C.; Bricault, P.; Chakrawarthy, R. S.; Daoud, J. J.; Finlay, P.; Garrett, P. E.; Hackman, G.; Hyland, B.; Leslie, J. R.; Morton, A. C.; Pearson, C. J.; Phillips, A. A.; Schumaker, M. A.; Svensson, C. E.; Valiente-Dobón, J. J.; Williams, S. J.; Zganjar, E. F.

    2007-08-01

    The half-life of Ne18 has been determined by detecting 1042-keV γ rays in the daughter F18 following the superallowed-Fermi β+ decay of samples implanted at the center of the 8πγ-ray spectrometer, a spherical array of 20 HPGe detectors. Radioactive Ne18 beams were produced on-line, mass-separated, and ionized using an electron-cyclotron-resonance ionization source at the ISAC facility at TRIUMF in Vancouver, Canada. This is the first high-precision half-life measurement of a superallowed Fermi β decay to utilize both a large-scale HPGe spectrometer and the isotope separation on-line technique. The half-life of Ne18, 1.6656 ± 0.0019 s, deduced following a 1.4σ correction for detector pulse pile-up, is four times more precise than the previous world average. As part of an investigation into potential systematic effects, the half-life of the heavier isotope Ne23 was determined to be 37.11 ± 0.06 s, a factor of 2 improvement over the previous precision.

  19. Half-life of the superallowed {beta}{sup +} emitter {sup 18}Ne

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Grinyer, G. F.; Andreoiu, C.; Finlay, P.

    The half-life of {sup 18}Ne has been determined by detecting 1042-keV {gamma} rays in the daughter {sup 18}F following the superallowed-Fermi {beta}{sup +} decay of samples implanted at the center of the 8{pi}{gamma}-ray spectrometer, a spherical array of 20 HPGe detectors. Radioactive {sup 18}Ne beams were produced on-line, mass-separated, and ionized using an electron-cyclotron-resonance ionization source at the ISAC facility at TRIUMF in Vancouver, Canada. This is the first high-precision half-life measurement of a superallowed Fermi {beta} decay to utilize both a large-scale HPGe spectrometer and the isotope separation on-line technique. The half-life of {sup 18}Ne, 1.6656 {+-} 0.0019 s,more » deduced following a 1.4{sigma} correction for detector pulse pile-up, is four times more precise than the previous world average. As part of an investigation into potential systematic effects, the half-life of the heavier isotope {sup 23}Ne was determined to be 37.11 {+-} 0.06 s, a factor of 2 improvement over the previous precision.« less

  20. Ultra-Low Noise Germanium Neutrino Detection system (ULGeN).

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cabrera-Palmer, Belkis; Barton, Paul

    Monitoring nuclear power plant operation by measuring the antineutrino flux has become an active research field for safeguards and non-proliferation. We describe various efforts to demonstrate the feasibility of reactor monitoring based on the detection of the Coherent Neutrino Nucleus Scattering (CNNS) process with High Purity Germanium (HPGe) technology. CNNS detection for reactor antineutrino energies requires lowering the electronic noise in low-capacitance kg-scale HPGe detectors below 100 eV as well as stringent reduction in other particle backgrounds. Existing state- of-the-art detectors are limited to an electronic noise of 95 eV-FWHM. In this work, we employed an ultra-low capacitance point-contact detectormore » with a commercial integrated circuit preamplifier- on-a-chip in an ultra-low vibration mechanically cooled cryostat to achieve an electronic noise of 39 eV-FWHM at 43 K. We also present the results of a background measurement campaign at the Spallation Neutron Source to select the area with sufficient low background to allow a successful first-time measurement of the CNNS process.« less

  1. New isotope technologies in environmental physics

    NASA Astrophysics Data System (ADS)

    Povinec, P. P.; Betti, M.; Jull, A. J. T.; Vojtyla, P.

    2008-02-01

    As the levels of radionuclides observed at present in the environment are very low, high sensitive analytical systems are required for carrying out environmental investigations. We review recent progress which has been done in low-level counting techniques in both radiometrics and mass spectrometry sectors, with emphasis on underground laboratories, Monte Carlo (GEANT) simulation of background of HPGe detectors operating in various configurations, secondary ionisation mass spectrometry, and accelerator mass spectrometry. Applications of radiometrics and mass spectrometry techniques in radioecology and climate change studies are presented and discussed as well. The review should help readers in better orientation on recent developments in the field of low-level counting and spectrometry, and to advice on construction principles of underground laboratories, as well as on criteria how to choose low or high energy mass spectrometers for environmental investigations.

  2. A methodology to evaluate occupational internal exposure to fluorine-18.

    PubMed

    Oliveira, C M; Dantas, A L A; Dantas, B M

    2009-11-15

    The objective of this work is to develop procedures for internal monitoring of (18)F to be applied in cases of possible incorporation of fluoride and (18)FDG, using in vivo and in vitro methods of measurements. The Na I (Tl) 8" x 4" scintillation detector installed at IRD-Whole Body Counter was calibrated for measurements with a whole body anthropomorphic phantom, simulating homogeneous distribution of (18)F in the body. The NaI(Tl) 3"x 3" scintillation detector installed at the IRD-Whole Body Counter was calibrated for in vivo measurements with a brain phantom inserted in an artificial skull, simulating (18)FDG incorporation. The HPGe detection system installed at the IRD-Bioassay Laboratory was calibrated for in vitro measurements of urine samples with 1 liter plastic bottles containing a standard liquid source. A methodology for bioassay data interpretation, based on standard ICRP models edited with the software AIDE-version 6, was established. It is concluded that in vivo measurements have sufficient sensitivity for monitoring (18)F in the forms of fluoride and (18)FDG. The use of both in vitro and in vivo bioassay data can provide useful information for the interpretation of bioassay data in cases of accidental incorporation in order to identify the chemical form of (18)F incorporated.

  3. A feasibility and optimization study to determine cooling time and burnup of advanced test reactor fuels using a nondestructive technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Navarro, Jorge

    2013-12-01

    The goal of this study presented is to determine the best available non-destructive technique necessary to collect validation data as well as to determine burn-up and cooling time of the fuel elements onsite at the Advanced Test Reactor (ATR) canal. This study makes a recommendation of the viability of implementing a permanent fuel scanning system at the ATR canal and leads3 to the full design of a permanent fuel scan system. The study consisted at first in determining if it was possible and which equipment was necessary to collect useful spectra from ATR fuel elements at the canal adjacent tomore » the reactor. Once it was establish that useful spectra can be obtained at the ATR canal the next step was to determine which detector and which configuration was better suited to predict burnup and cooling time of fuel elements non-destructively. Three different detectors of High Purity Germanium (HPGe), Lanthanum Bromide (LaBr3), and High Pressure Xenon (HPXe) in two system configurations of above and below the water pool were used during the study. The data collected and analyzed was used to create burnup and cooling time calibration prediction curves for ATR fuel. The next stage of the study was to determine which of the three detectors tested was better suited for the permanent system. From spectra taken and the calibration curves obtained, it was determined that although the HPGe detector yielded better results, a detector that could better withstand the harsh environment of the ATR canal was needed. The in-situ nature of the measurements required a rugged fuel scanning system, low in maintenance and easy to control system. Based on the ATR canal feasibility measurements and calibration results it was determined that the LaBr3 detector was the best alternative for canal in-situ measurements; however in order to enhance the quality of the spectra collected using this scintillator a deconvolution method was developed. Following the development of the deconvolution method for ATR applications the technique was tested using one-isotope, multi-isotope and fuel simulated sources. Burnup calibrations were perfomed using convoluted and deconvoluted data. The calibrations results showed burnup prediction by this method improves using deconvolution. The final stage of the deconvolution method development was to perform an irradiation experiment in order to create a surrogate fuel source to test the deconvolution method using experimental data. A conceptual design of the fuel scan system is path forward using the rugged LaBr3 detector in an above the water configuration and deconvolution algorithms.« less

  4. Phase II Upgrade of the GERDA Experiment for the Search of Neutrinoless Double Beta Decay

    NASA Astrophysics Data System (ADS)

    Majorovits, B.

    Observation of neutrinoless double beta decay could answer the question regarding the Majorana or Dirac nature of neutrinos. The GERDA experiment utilizes HPGe detectors enriched with the isotope 76Ge to search for this process. Recently the GERDA collaboration has unblinded data of Phase I of the experiment. In order to further improve the sensitivity of the experiment, additionally to the coaxial detectors used, 30 BEGe detectors made from germanium enriched in 76Ge will be deployed in GERDA Phase II. BEGe detectors have superior PSD capability, thus the background can be further reduced. The liquid argon surrounding the detector array will be instrumented in order to reject background by detecting scintillation light induced in the liquid argon by radiation. After a short introduction the hardware preparations for GERDA Phase II as well as the processing and characterization of the 30 BEGe detectors are discussed.

  5. A New Approach for the Determination of Dose Rate and Radioactivity for Detected Gamma Nuclides Using an Environmental Radiation Monitor Based on an NaI(Tl) Detector.

    PubMed

    Ji, Young-Yong; Kim, Chang-Jong; Lim, Kyo-Sun; Lee, Wanno; Chang, Hyon-Sock; Chung, Kun Ho

    2017-10-01

    To expand the application of dose rate spectroscopy to the environment, the method using an environmental radiation monitor (ERM) based on a 3' × 3' NaI(Tl) detector was used to perform real-time monitoring of the dose rate and radioactivity for detected gamma nuclides in the ground around an ERM. Full-energy absorption peaks in the energy spectrum for dose rate were first identified to calculate the individual dose rates of Bi, Ac, Tl, and K distributed in the ground through interference correction because of the finite energy resolution of the NaI(Tl) detector used in an ERM. The radioactivity of the four natural radionuclides was then calculated from the in situ calibration factor-that is, the dose rate per unit curie-of the used ERM for the geometry of the ground in infinite half-space, which was theoretically estimated by Monte Carlo simulation. By an intercomparison using a portable HPGe and samples taken from the ground around an ERM, this method to calculate the dose rate and radioactivity of four nuclides using an ERM was experimentally verified and finally applied to remotely monitor them in real-time in the area in which the ERM had been installed.

  6. Improved background suppression for radiative capture reactions at LUNA with HPGe and BGO detectors

    NASA Astrophysics Data System (ADS)

    Boeltzig, A.; Best, A.; Imbriani, G.; Junker, M.; Aliotta, M.; Bemmerer, D.; Broggini, C.; Bruno, C. G.; Buompane, R.; Caciolli, A.; Cavanna, F.; Chillery, T.; Ciani, G. F.; Corvisiero, P.; Csedreki, L.; Davinson, T.; deBoer, R. J.; Depalo, R.; Di Leva, A.; Elekes, Z.; Ferraro, F.; Fiore, E. M.; Formicola, A.; Fülöp, Z.; Gervino, G.; Guglielmetti, A.; Gustavino, C.; Gyürky, G.; Kochanek, I.; Menegazzo, R.; Mossa, V.; Pantaleo, F. R.; Paticchio, V.; Perrino, R.; Piatti, D.; Prati, P.; Schiavulli, L.; Stöckel, K.; Straniero, O.; Strieder, F.; Szücs, T.; Takács, M. P.; Trezzi, D.; Wiescher, M.; Zavatarelli, S.

    2018-02-01

    Direct measurements of small nuclear reaction cross sections require a low background in the signal region of interest to achieve the necessary sensitivity. We describe two complementary detector setups that have been used for studies of ({{p}},γ ) reactions with solid targets at the Laboratory for Underground Nuclear Astrophysics (LUNA): a high-purity germanium detector and a bismuth germanate (BGO) detector. We present the effect of a customised lead shielding on the measured background spectra in the two detector setups at LUNA. We developed a model to describe the contributions of environmental and intrinsic backgrounds in the BGO detector measurements. Furthermore we present an upgrade of the data acquisition system for our BGO detector, which allows us to exploit the features of the segmented detector and overcome some of the limitations encountered in previous experiments. We conclude with a discussion on the improved sensitivity of the presented setups, and the benefits for ongoing and possible future measurements.

  7. Conceptual design of a hybrid neutron-gamma detector for study of β-delayed neutrons at the RIB facility of RIKEN

    NASA Astrophysics Data System (ADS)

    Tarifeño-Saldivia, A.; Tain, J. L.; Domingo-Pardo, C.; Calviño, F.; Cortés, G.; Phong, V. H.; Riego, A.; Agramunt, J.; Algora, A.; Brewer, N.; Caballero-Folch, R.; Coleman-Smith, P. J.; Davinson, T.; Dillmann, I.; Estradé, A.; Griffin, C. J.; Grzywacz, R.; Harkness-Brennan, L. J.; Kiss, G. G.; Kogimtzis, M.; Labiche, M.; Lazarus, I. H.; Lorusso, G.; Matsui, K.; Miernik, K.; Montes, F.; Morales, A. I.; Nishimura, S.; Page, R. D.; Podolyák, Z. S.; Pucknell, V. F. E.; Rasco, B. C.; Regan, P.; Rubio, B.; Rykaczewski, K. P.; Saito, Y.; Sakurai, H.; Simpson, J.; Sokol, E.; Surman, R.; Svirkhin, A.; Thomas, S. L.; Tolosa, A.; Woods, P.

    2017-04-01

    The conceptual design of the BRIKEN neutron detector at the radioactive ion beam factory (RIBF) of the RIKEN Nishina Center is reported. The BRIKEN setup is a complex system aimed at detecting heavy-ion implants, β particles, γ rays and β-delayed neutrons. The whole setup includes the Advanced Implantation Detection Array (AIDA), two HPGe Clover detectors and up to 166 3He-filled counters embedded in a high-density polyethylene moderator. The design is quite complex due to the large number and different types of 3He-tubes involved and the additional constraints introduced by the ancillary detectors for charged particles and γ rays. This article reports on a novel methodology developed for the conceptual design and optimisation of the 3He-counter array, aiming for the best possible performance in terms of neutron detection. The algorithm is based on a geometric representation of two selected detector parameters of merit, namely, the average neutron detection efficiency and the efficiency flatness as a function of a reduced number of geometric variables. The response of the neutron detector is obtained from a systematic Monte Carlo simulation implemented in GEANT4. The robustness of the algorithm allowed us to design a versatile detection system, which operated in hybrid mode includes the full neutron counter and two clover detectors for high-precision gamma spectroscopy. In addition, the system can be reconfigured into a compact mode by removing the clover detectors and re-arranging the 3He tubes in order to maximize the neutron detection performance. Both operation modes shows a rather flat and high average efficiency. In summary, we have designed a system which shows an average efficiency for hybrid mode (3He tubes + clovers) of 68.6% and 64% for neutron energies up to 1 and 5 MeV, respectively. For compact mode (only 3He tubes), the average efficiency is 75.7% and 71% for neutron energies up to 1 and 5 MeV, respectively. The performance of the BRIKEN detection system has been also quantified by means of Monte Carlo simulations with different neutron energy distributions.

  8. Simulation and experimental verification of prompt gamma-ray emissions during proton irradiation.

    PubMed

    Schumann, A; Petzoldt, J; Dendooven, P; Enghardt, W; Golnik, C; Hueso-González, F; Kormoll, T; Pausch, G; Roemer, K; Fiedler, F

    2015-05-21

    Irradiation with protons and light ions offers new possibilities for tumor therapy but has a strong need for novel imaging modalities for treatment verification. The development of new detector systems, which can provide an in vivo range assessment or dosimetry, requires an accurate knowledge of the secondary radiation field and reliable Monte Carlo simulations. This paper presents multiple measurements to characterize the prompt γ-ray emissions during proton irradiation and benchmarks the latest Geant4 code against the experimental findings. Within the scope of this work, the total photon yield for different target materials, the energy spectra as well as the γ-ray depth profile were assessed. Experiments were performed at the superconducting AGOR cyclotron at KVI-CART, University of Groningen. Properties of the γ-ray emissions were experimentally determined. The prompt γ-ray emissions were measured utilizing a conventional HPGe detector system (Clover) and quantitatively compared to simulations. With the selected physics list QGSP_BIC_HP, Geant4 strongly overestimates the photon yield in most cases, sometimes up to 50%. The shape of the spectrum and qualitative occurrence of discrete γ lines is reproduced accurately. A sliced phantom was designed to determine the depth profile of the photons. The position of the distal fall-off in the simulations agrees with the measurements, albeit the peak height is also overestimated. Hence, Geant4 simulations of prompt γ-ray emissions from irradiation with protons are currently far less reliable as compared to simulations of the electromagnetic processes. Deviations from experimental findings were observed and quantified. Although there has been a constant improvement of Geant4 in the hadronic sector, there is still a gap to close.

  9. Real time method and computer system for identifying radioactive materials from HPGe gamma-ray spectroscopy

    DOEpatents

    Rowland, Mark S.; Howard, Douglas E.; Wong, James L.; Jessup, James L.; Bianchini, Greg M.; Miller, Wayne O.

    2007-10-23

    A real-time method and computer system for identifying radioactive materials which collects gamma count rates from a HPGe gamma-radiation detector to produce a high-resolution gamma-ray energy spectrum. A library of nuclear material definitions ("library definitions") is provided, with each uniquely associated with a nuclide or isotope material and each comprising at least one logic condition associated with a spectral parameter of a gamma-ray energy spectrum. The method determines whether the spectral parameters of said high-resolution gamma-ray energy spectrum satisfy all the logic conditions of any one of the library definitions, and subsequently uniquely identifies the material type as that nuclide or isotope material associated with the satisfied library definition. The method is iteratively repeated to update the spectrum and identification in real time.

  10. Gamma-Ray Spectroscopy at TRIUMF-ISAC: the New Frontier of Radioactive Ion Beam Research

    NASA Astrophysics Data System (ADS)

    Ball, G. C.; Andreoiu, C.; Austin, R. A. E.; Bandyopadhyay, D.; Becker, J. A.; Bricault, P.; Brown, N.; Chan, S.; Churchman, R.; Colosimo, S.; Coombes, H.; Cross, D.; Demand, G.; Drake, T. E.; Dombsky, M.; Ettenauer, S.; Finlay, P.; Furse, D.; Garnsworthy, A.; Garrett, P. E.; Green, K. L.; Grinyer, G. F.; Hyland, B.; Hackman, G.; Kanungo, R.; Kulp, W. D.; Lassen, J.; Leach, K. G.; Leslie, J. R.; Mattoon, C.; Melconian, D.; Morton, A. C.; Pearson, C. J.; Phillips, A. A.; Rand, E.; Sarazin, F.; Svensson, C. E.; Sumithrarachchi, S.; Schumaker, M. A.; Triambak, S.; Waddington, J. C.; Walker, P. M.; Williams, S. J.; Wood, J. L.; Wong, J.; Zganjar, E. F.

    2009-03-01

    High-resolution gamma-ray spectroscopy is essential to fully exploit the unique scientific opportunities at the next generation radioactive ion beam facilities such as the TRIUMF Isotope Separator and Accelerator (ISAC). At ISAC the 8π spectrometer and its associated auxiliary detectors is optimize for β-decay studies while TIGRESS an array of segmented clover HPGe detectors has been designed for studies with accelerated beams. This paper gives a brief overview of these facilities and also presents recent examples of the diverse experimental program carried out at the 8π spectrometer.

  11. Position Sensitive Proximity Charge Sensing Readout of HPGe Detectors

    NASA Astrophysics Data System (ADS)

    Priest, Anders Peterson

    Electrode segmentation is a necessity to achieve position sensitivity in semicon- ductor radiation detectors. Traditional segmentation requires decreasing electrode sizes while increasing channel numbers to achieve very fine position resolution. These electrodes can be complicated to fabricate, and many electrodes with individual electronic channels are required to instrument large detector areas. To simplify the fabrication process, we have moved the readout electrodes onto a printed circuit board that is positioned above the ionization type detection material. In this scheme, charge from radiation interactions will be shared amongst several electrodes, allowing for position interpolation. Because events can be reconstructed in between electrodes, fewer electrodes are needed to instrument large detector areas. The proximity charge sensing method of readout promises to simplify detector fabrication while maintaining the position resolution that is required by fields such as homeland security, astrophysics, environmental remediation, nuclear physics, and medical imaging. We performed scanning measurements on a proof of principle detector that we fabricated at Lawrence Berkeley National Laboratory (LBNL). These measurements showed that position resolution much finer than the strip pitch was achievable using the proximity charge readout method. We performed analytic calculations and Monte Carlo modeling to optimize the readout electrode geometry for a larger detector to test the limits of this technology. We achieved an average position resolution of 288 microm with eight proximity electrodes at a 5 mm pitch and 1 mm strip width, set 100 microm away from the detector surface by a Kapton spacer. To achieve this resolution using standard technologies, 300 microm pitch strips are necessary, and would require 100 channels to instrument the same area. Through our optimization calculations, we found that there is a trade-off between position resolution and energy resolution, and this system provided comparatively poor energy resolution by HPGe standards, with 4.7 keV FWHM at 59.5 keV. With another electrode geometry, we were able to achieve 2.9 keV FWHM at 59.5 keV. This dissertation describes the work we completed to achieve these results.

  12. Detection of Special Nuclear Material with High Purity Germanium (HPGe) and Mercuric Iodide (HgI2) Gamma Detectors

    DTIC Science & Technology

    2003-03-01

    to Achieve and Verify Deep Reductions in the Nuclear Arsenals. Ed. F. von Hippel and R.Z. Sagdeev. New York: Gordon and Breach Science Publishers... 1996 p . 1253-60. 21. Shleien, Bernard, Lester Slaback, and Brian Birky, Handbook of Health Physics and Radiological Health, 3rd Edition. Williams...70 13. Pu- 240 key gammas

  13. Natural and man-made radioactivity in soils and plants around the research reactor of Inshass.

    PubMed

    Higgy, R H; Pimpl, M

    1998-12-01

    The specific radioactivities of the U-series, 232Th, 137Cs and 40K were measured in soil samples around the Inshass reactor in Cairo, using a gamma-ray spectrometer with a HpGe detector. The alpha activity of 238U, 234U and 235U was measured in the same soil samples by surface barrier detectors after radiochemical separation and the obtained results were compared with the specific activities determined by gamma-measurements. The alpha-activity of 238Pu, 239+240Pu, 241Am, 242Cm and 244Cm was measured after radiochemical separation by surface barrier detectors for both soil and plant samples. Then beta-activity of 241Pu was measured using liquid scintillation spectrometry.

  14. The νGeN experiment at the Kalinin Nuclear Power Plant

    NASA Astrophysics Data System (ADS)

    Belov, V.; Brudanin, V.; Egorov, V.; Filosofov, D.; Fomina, M.; Gurov, Yu.; Korotkova, L.; Lubashevskiy, A.; Medvedev, D.; Pritula, R.; Rozova, I.; Rozov, S.; Sandukovsky, V.; Timkin, V.; Yakushev, E.; Yurkowski, J.; Zhitnikov, I.

    2015-12-01

    The ν GeN is new experiment at the Kalinin Nuclear Power Plant (KNPP) for detection of coherent Neutrino-Ge Nucleus elastic scattering. Recent neutrino and Dark Matter search experiments have revolutionized the detection of rear events, and rear events with low energies, in particular. Experiments have achieved sensitivities on the level of several events per hundred kg of detector material per day with energy thresholds from few hundred eV. This opens up a new unique possibility for experimental detection of neutrino-nucleus coherent scattering that has been considered to be impossible so far. The νGeN project uses low threshold high-purity Ge-detectors (HPGe) developed by JINR (Dubna, Russia) in collaboration with BSI (Baltic Scientific Instruments, Riga, Latvia) for creation of a setup designated for first observation of neutrino coherent scattering on Ge. As a powerful neutrino source the experiment will use electron antineutrinos from one of the power-generating units (reactor unit #3) of the KNPP. The coherent neutrino scattering will be observed using a differential method that compares 1) the spectra measured at the reactor operation and shut-down periods; 2) the spectra measured at different distances from the reactor core during the reactor operation. For a setup placed at a 10 m distance from the center of reactor core and with an energy threshold of 350 eV up to tens of events corresponding to neutrino coherent scattering on Ge are expected to be detected per day in the constructed setup with four HPGe low-energy-threshold detectors (~ 400 grams each). The setup sensitivity will be even more increased by using new detectors with total mass up to 5 kg.

  15. Development, Testing and Validation of a Waste Assay System for the Measurement and Characterisation of Active Spent Fuel Element Debris From UK Magnox Reactors - 12533

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mason, John A.; Burke, Kevin J.; Looman, Marc R.

    2012-07-01

    This paper describes the development, testing and validation of a waste measurement instrument for characterising active remote handled radioactive waste arising from the operation of Magnox reactors in the United Kingdom. Following operation in UK Magnox gas cooled reactors and a subsequent period of cooling, parts of the magnesium-aluminium alloy cladding were removed from spent fuel and the uranium fuel rods with the remaining cladding were removed to Sellafield for treatment. The resultant Magnox based spent fuel element debris (FED), which constitutes active intermediate level waste (ILW) has been stored in concrete vaults at the reactor sites. As part ofmore » the decommissioning of the FED vaults the FED must be removed, measured and characterised and placed in intermediate storage containers. The present system was developed for use at the Trawsfynydd nuclear power station (NPS), which is in the decommissioning phase, but the approach is potentially applicable to FED characterisation at all of the Magnox reactors. The measurement system consists of a heavily shielded and collimated high purity Germanium (HPGe) detector with electromechanical cooling and a high count-rate preamplifier and digital multichannel pulse height analyser. The HPGe based detector system is controlled by a software code, which stores the measurement result and allows a comprehensive analysis of the measured FED data. Fuel element debris is removed from the vault and placed on a tray to a uniform depth of typically 10 cm for measurement. The tray is positioned approximately 1.2 meters above the detector which views the FED through a tungsten collimator with an inverted pyramid shape. At other Magnox sites the positions may be reversed with the shielded and collimated HPGe detector located above the tray on which the FED is measured. A comprehensive Monte Carlo modelling and analysis of the measurement process has been performed in order to optimise the measurement geometry and eliminate interferences from radioactive sources and FED in the immediate vicinity of the measurement position. The detector system has been calibrated and high activity radioactive sources of Cs-137, Co-60 and Na-22 have been used to validate the measurement process. The data acquisition and analysis software code has been tested and validated in keeping with the software quality assurance requirements of both ISO:9001-2008 - TICK-IT in the UK and NQA-1. The measurement and analysis system has been comprehensively tested with high activity sources, is flexible and may be applicable to a wide range of remote handled radioactive waste measurement applications. It is due to be installed at Trawsfynydd NPS later this year. This paper describes the Waste Tray Assay System (WTAS) that has been developed for the measurement of Magnox FED waste. The WTAS has been tested with a range of radioactive sources and its operation has been simulated with benchmarked MCNP Monte Carlo calculations. The measurement software has been validated as has the operation of the system for a range of strong radioactive sources. A system based on the design is due for installation and operation in 2012. The system has application to the measurement of Magnox Fuel Element Debris (FED) waste at other Magnox reactor sites. The major design objective of the WTAS that has been achieved is the ability of the assay system to determine the content of Cs-137, and in turn to enable the fissile burden to be assessed using a radionuclide fingerprint, in the presence of higher and highly variable quantities of Co-60, typically from nimonic springs. The approach can be used in other Magnox FED waste configurations where the detector is located above the FED waste sorting tray and where the collimation is fixed below the detector and at a distance above the tray. In this case, which has also been investigated, there are different shielding problems and mechanical support issues. The extensive use of MCNP Monte Carlo modelling to simulate the geometry of the sorting cell and the distribution of radioactive sources has helped to ensure that all of the detector shielding requirements are addressed and suitable Cs-137 and Co-60 discrimination can be achieved. The WTAS in its present form or in other configurations has relevance to the measurement of other active ILW and highly active RH waste. Examples include high activity RH LLW and RH TRU (Transuranic) waste as defined in the United States arising from both commercial nuclear and Department of Energy (DOE) operations. The analysis is able to analyse a range of radionuclides beyong those expected in the Magnox FED cases. (authors)« less

  16. PHOTON SPECTRA IN NPL STANDARD RADIONUCLIDE NEUTRON FIELDS.

    PubMed

    Roberts, N J

    2017-09-23

    A HPGe detector has been used to measure the photon spectra from the majority of radionuclide neutron sources in use at NPL (252Cf, 241Am-Be, 241Am-Li, 241Am-B). The HPGe was characterised then modelled to produce a response matrix. The measured pulse height spectra were then unfolded to produce photon fluence spectra. Changes in the photon spectrum with time from a 252Cf source are evident. Spectra from a 2-year-old and 42-year-old 252Cf source are presented showing the change from a continuum to peaks from long-lived isotopes of Cf. Other radionuclide neutron source spectra are also presented and discussed. The new spectra were used to improve the photon to neutron dose equivalent ratios from some earlier work at NPL with GM tubes and EPDs. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  17. Quarterly Report 24.1.3.1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shusterman, Jennifer A.

    We are measuring freshly separated uranium samples using modern list mode (event-by-event) electronics with high resolution HPGe detectors to study the in-growth behaviors of uranium daughters’ gamma-rays. These data will show how we can use gamma-ray spectroscopy to determine the separation date for processed uranium. With this knowledge, one can obtain proper uranium isotope ratios using standard safeguards accountability software such as U-235 or MGAU.

  18. Precision measurement of ^23Al beta-decay

    NASA Astrophysics Data System (ADS)

    Zhai, Yongjun; Iacob, V. E.; Hardy, J. C.; Al-Abdullah, T.; Banu, A.; Fu, C.; Golovko, V. V.; McCleskey, M.; Nica, N.; Park, H. I.; Tabacaru, G.; Tribble, R. E.; Trache, L.

    2007-10-01

    The beta-decay of ^23Al (See [1]) was re-measured with higher statistics and better accuracy at Texas A&M University. Using MARS we produced and separated pure ^23Al at 4000 pps, with a 48 MeV/u ^24Mg beam via the ^24Mg (p, 2n)^ 23Al reaction on a H2 cryogenic target. New β and β-γ coincidence measurements were made with a scintillator, an HPGe detector with BGO shielding and the fast tape transport system. The BGO Compton shield very much improved the quality of the γ spectra around the transition from the IAS state at 7803 keV. From the measured β singles and β-γ coincidence decay spectra we obtained an improved β-decay scheme and a more precise lifetime: t=447(4) ms. We use the method of detailed balance to obtain absolute β-branching ratios and absolute logft values for transitions to final states in ^23Mg. For this method, precise efficiency calibration of the HPGe detector up to about 8 MeV is needed. We extended our previous efficiency calibration to the range Eγ=3.5-8 MeV using the β-decay of ^24Al. [1] V.E. Iacob, Y. Zhai et al., Phys. Rev. C 74, 045810 (2006).

  19. Background rejection of TEXONO experiment to explore the sub-keV energy region with HPGe detector

    NASA Astrophysics Data System (ADS)

    Singh, M. K.; Sharma, V.; Singh, L.; Chen, J. H.; Singh, V.; Subrahmanyam, V. S.; Soma, A. K.; Wong, H. T.

    2017-10-01

    To observe the neutrino-nucleus coherent scattering as well as for dark matter search, a detection system with ultra-low energy high purity germanium detector has been set up by the TEXONO Collaboration in Kuo-Sheng Nuclear Power Plant. Owing to the weak nature and small recoil energy of these rare events, understanding of background sources and their contribution to the energy spectrum are the key factors in this experiment. In this report, we will focus in detail on the different sources of backgrounds in the TEXONO experiment and the techniques used to reject/minimize them.

  20. First Results with TIGRESS and Accelerated Radioactive Ion Beams from ISAC: Coulomb Excitation of 20,21,29Na

    NASA Astrophysics Data System (ADS)

    Schumaker, M. A.; Hurst, A. M.; Svensson, C. E.; Wu, C. Y.; Becker, J. A.; Cline, D.; Hackman, G.; Pearson, C. J.; Stoyer, M. A.; Andreyev, A.; Austin, R. A. E.; Ball, G. C.; Bandyopadhyay, D.; Barton, C. J.; Boston, A. J.; Boston, H. C.; Buchmann, L.; Churchman, R.; Cifarelli, F.; Colosimo, S. J.; Cooper, R. J.; Cross, D. S.; Dashdorj, D.; Demand, G. A.; Dimmock, M. R.; Djongolov, M.; Drake, T. E.; Finlay, P.; Gallant, A. T.; Garrett, P. E.; Gray-Jones, C.; Green, K. L.; Grint, A. N.; Grinyer, G. F.; Harkness, L. J.; Hayes, A. B.; Kanungo, R.; Leach, K. G.; Kulp, W. D.; Lisetskiy, A. F.; Lee, G.; Lloyd, S.; Maharaj, R.; Martin, J.-P.; Millar, B. A.; Moisan, F.; Morton, A. C.; Mythili, S.; Nelson, L.; Newman, O.; Nolan, P. J.; Orce, J. N.; Oxley, D. C.; Padilla-Rodal, E.; Phillips, A. A.; Porter-Peden, M.; Ressler, J. J.; Rigby, S. V.; Roy, R.; Ruiz, C.; Sarazin, F.; Scraggs, D. P.; Sumithrarachchi, C. S.; Triambak, S.; Waddington, J. C.; Walker, P. M.; Wan, J.; Whitbeck, A.; Williams, S. J.; Wong, J.; Wood, J. L.

    2009-03-01

    The TRIUMF-ISAC Gamma-Ray Escape Suppressed Spectrometer (TIGRESS) is a state-of-the-art γ-ray spectrometer being constructed at the ISAC-II radioactive ion beam facility at TRIUMF. TIGRESS will be comprised of twelve 32-fold segmented high-purity germanium (HPGe) clover-type γ-ray detectors, with BGO/CsI(Tl) Compton-suppression shields, and is currently operational at ISAC-II in an early-implementation configuration of six detectors. Results have been obtained for the first experiments performed using TIGRESS, which examined the A = 20, 21, and 29 isotopes of Na by Coulomb excitation.

  1. High-resolution γ-ray spectroscopy: a versatile tool for nuclear β-decay studies at TRIUMF-ISAC

    NASA Astrophysics Data System (ADS)

    Ball, G. C.; Achtzehn, T.; Albers, D.; Khalili, J. S. Al; Andreoiu, C.; Andreyev, A.; Ashley, S. F.; Austin, R. A. E.; Becker, J. A.; Bricault, P.; Chan, S.; Chakrawarthy, R. S.; Churchman, R.; Coombes, H.; Cunningham, E. S.; Daoud, J.; Dombsky, M.; Drake, T. E.; Eshpeter, B.; Finlay, P.; Garrett, P. E.; Geppert, C.; Grinyer, G. F.; Hackman, G.; Hanemaayer, V.; Hyland, B.; Jones, G. A.; Koopmans, K. A.; Kulp, W. D.; Lassen, J.; Lavoie, J. P.; Leslie, J. R.; Litvinov, Y.; Macdonald, J. A.; Mattoon, C.; Melconian, D.; Morton, A. C.; Osborne, C. J.; Pearson, C. J.; Pearson, M.; Phillips, A. A.; Ressler, J. J.; Sarazin, F.; Schumaker, M. A.; Schwarzenberg, J.; Scraggs, H. C.; Smith, M. B.; Svensson, C. E.; Valiente-Dobon, J. J.; Waddington, J. C.; Walker, P. M.; Wendt, K.; Williams, S. J.; Wood, J. L.; Zganjar, E. F.

    2005-10-01

    High-resolution γ-ray spectroscopy is essential to fully exploit the unique, high-quality beams available at the next generation of radioactive ion beam facilities such as the TRIUMF isotope separator and accelerator (ISAC). The 8π spectrometer, which consists of 20 Compton-suppressed HPGe detectors, has recently been reconfigured for a vigorous research programme in weak interaction and nuclear structure physics. With the addition of a variety of ancillary detectors it has become the world's most powerful device dedicated to β-decay studies. This paper provides a brief overview of the apparatus and highlights from recent experiments.

  2. Characteristics of signals originating near the lithium-diffused N+ contact of high purity germanium p-type point contact detectors

    DOE PAGES

    Aguayo, E.; Amman, M.; Avignone, F. T.; ...

    2012-11-09

    A study of signals originating near the lithium-diffused n+ contact of p-type point contact (PPC) high purity germanium detectors (HPGe) is presented. The transition region between the active germanium and the fully dead layer of the n+ contact is examined. Energy depositions in this transition region are shown to result in partial charge collection. This provides a mechanism for events with a well defined energy to contribute to the continuum of the energy spectrum at lower energies. A novel technique to quantify the contribution from this source of background is introduced. Furthermore, experiments that operate germanium detectors with a verymore » low energy threshold may benefit from the methods presented herein.« less

  3. DESCANT--The DEuterated SCintillator Array for Neutron Tagging

    NASA Astrophysics Data System (ADS)

    Bildstein, Vinzenz; Garrett, P. E.; Bandyopadhay, D.; Bangay, J.; Bianco, L.; Demand, G.; Hadinia, B.; Leach, K. G.; Sumithrarachchi, C.; Wong, J.; Ashley, S. F.; Crider, B. P.; McEllistrem, M. T.; Peters, E. E.; Prados-Estévez, F. M.; Yates, S. W.; Vanhoy, J. R.; Ball, G. C.; Garnsworthy, A. B.; Hackman, G.; Pearson, C. J.; Sarazin, F.

    2014-09-01

    The DESCANT array at TRIUMF is designed to track neutrons from RIB experiments. DESCANT is composed of 70 close-packed deuterated organic liquid scintillators coupled to digital fast read-out ADC modules. This configuration will permit online pulse-shape discrimination between neutron and γ-ray events. The anisotropy of the n - d scattering will allow distinction of higher neutron multiplicities from scattering within the array and determination of the neutron energy spectrum directly from the pulse-height spectrum without using TOF. A prototype detector has been tested with monoenergetic neutrons at the accelerator laboratory of the University of Kentucky and a 24Mg(3He, n)26Si experiment has been performed with eight DESCANT detectors and two HPGe detectors. The results of the tests and the status of DESCANT will be presented.

  4. Experimental research of neutron yield and spectrum from deuterium gas-puff z-pinch on the GIT-12 generator at current above 2 MA

    NASA Astrophysics Data System (ADS)

    Cherdizov, R. K.; Fursov, F. I.; Kokshenev, V. A.; Kurmaev, N. E.; Labetsky, A. Yu; Ratakhin, N. A.; Shishlov, A. V.; Cikhardt, J.; Cikhardtova, B.; Klir, D.; Kravarik, J.; Kubes, P.; Rezac, K.; Dudkin, G. N.; Garapatsky, A. A.; Padalko, V. N.; Varlachev, V. A.

    2017-05-01

    The Z-pinch experiments with deuterium gas-puff surrounded by an outer plasma shell were carried out on the GIT-12 generator (Tomsk, Russia) at currents of 2 MA. The plasma shell consisting of hydrogen and carbon ions was formed by 48 plasma guns. The deuterium gas-puff was created by a fast electromagnetic valve. This configuration provides an efficient mode of the neutron production in DD reaction, and the neutron yield reaches a value above 1012 neutrons per shot. Neutron diagnostics included scintillation TOF detectors for determination of the neutron energy spectrum, bubble detectors BD-PND, a silver activation detector, and several activation samples for determination of the neutron yield analysed by a Sodium Iodide (NaI) and a high-purity Germanium (HPGe) detectors. Using this neutron diagnostic complex, we measured the total neutron yield and amount of high-energy neutrons.

  5. Energy reconstruction of an n-type segmented inverted coaxial point-contact HPGe detector

    DOE PAGES

    Salathe, M.; Cooper, R. J.; Crawford, H. L.; ...

    2017-06-27

    We have characterized, for the rst time, an n-type segmented Inverted Coaxial Point-Contact detector. This novel detector technology relys on a large variation in drift time of the majority charge carriers, as well as image and net charges observed on the segments, to achieve a potential -ray interaction position resolution of better than 1 mm. However, the intrinsic energy resolution in such a detector is poor (more than 20 keV at 1332 keV) because of charge (electron) trapping e ects. We propose an algorithm that enables restoration of the resolution to a value of 3.44 0.03 keV at 1332 keVmore » for events with a single interaction. The algorithm is based on a measurement of the azimuthal angle and the electron drift time of a given event; the energy of the event is corrected as a function of these two values.« less

  6. Sci-Sat AM: Radiation Dosimetry and Practical Therapy Solutions - 11: Commissioning of a system for the measurement of electron stopping powers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McEwen, Malcolm; Roy, Timothy; Tessier, Frederic

    Purpose: To develop the techniques required to experimentally determine electron stopping powers for application in primary standards and dosimetry protocols. Method and Materials: A large-volume HPGe detector system (>80% efficiency) was commissioned for the measurement of high energy (5–35 MeV) electron beams. As a proof of principle the system was used with a Y-90/Sr-90 radioactive source. Thin plates of absorbing material (< 0.1 gcm-2) were then placed between the source and detector and the emerging electron spectrum was acquired. The full experimental geometry was modelled using the EGSnrc package to validate the detector design, optimize the experimental setup and comparemore » measured and calculated spectra. Results: The biggest challenge using a beta source was to identify a robust spectral parameter to determine for each measurement. An end-point-fitting routine was used to determine the maximum energy, Emax, of the beta spectrum for each absorber thickness t. The parameter dEmax/dt is related to the electron stopping power and the same routine was applied to both measured and simulated spectra. Although the standard uncertainty in dEmax/dt was of the order of 5 %, by taking the ratio of measured and Monte Carlo values for dEmax/dt the uncertainty of the fitting routine was eliminated and the uncertainty was reduced to less than 2 %. The agreement between measurement and simulation was within this uncertainty estimate. Conclusion: The investigation confirmed the experimental approach and demonstrated that EGSnrc could accurately determine correction factors that will be required for the final measurement setup in a linac beam.« less

  7. Low Background Signal Readout Electronics for the MAJORANA DEMONSTRATOR

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Guinn, I.; Abgrall, N.; Arnquist, Isaac J.

    2015-03-18

    The Majorana Demonstrator (MJD)[1] is an array of p-type point contact (PPC) high purity Germanium (HPGe) detectors intended to search for neutrinoless double beta decay (0vBB decay) in 76Ge. MJD will consist of 40 kg of detectors, 30 kg of which will be isotopically enriched to 87% 76Ge. The array will consist of 14 strings of four or ve detectors placed in two separate cryostats. One of the main goals of the experiment is to demonstrate the feasibility of building a tonne-scale array of detectors to search for 0vBB decay with a much higher sensitivity. This involves acheiving backgrounds inmore » the 4 keV region of interest (ROI) around the 2039 keV Q-value of the BB decay of less than 1 count/ROI-t-y. Because many backgrounds will not directly scale with detector mass, the specific background goal of MJD is less than 3 counts/ROI-t-y.« less

  8. Determination of photon emission probability for the main gamma ray and half-life measurements of 64Cu.

    PubMed

    Pibida, L; Zimmerman, B; Bergeron, D E; Fitzgerald, R; Cessna, J T; King, L

    2017-11-01

    The National Institute of Standards and Technology (NIST) performed new standardization measurements for 64 Cu. As part of this work the photon emission probability for the main gamma-ray line and the half-life were determined using several high-purity germanium (HPGe) detectors. Half-life determinations were also carried out with a NaI(Tl) well counter and two pressurized ionization chambers. Published by Elsevier Ltd.

  9. How to improve x-ray scattering techniques to quantify bone mineral density using spectroscopy

    PubMed Central

    Krmar, M.; Ganezer, K.

    2012-01-01

    Purpose: The purpose of this study was to develop a new diagnostic technique for measuring bone mineral density (BMD) for the assessment of osteoporosis, which improves upon the coherent to Compton scattering ratio (CCSR) method, which was first developed in the 1980s. To help the authors achieve these goals, they have identified and studied two new indices for CCSR, the forward scattered to backward scattered (FS-BS) and the forward scattered to transmitted (FS-T) ratios. They believe that, at small angles, these two parameters can offer a practical in vivo determination of BMD that can be used to overcome the limitations of past CCSR systems, including high radiation dosages, costs, and examination durations. Methods: In previous CCSR studies, a high-activity radioactive source with a long half-live (usually 241Am) and an expensive and bulky cryogenic HPGe detector were applied to both in vivo and in vitro measurements. To make this technique more suitable for clinical applications, the possibility of using a standard diagnostic x-ray tube generating a continuous spectrum was investigated in this paper. Scattered radiation from trabecular bone-simulating phantoms containing various mineral densities that span the normal range of in vivo BMD was collected in this study using relatively inexpensive noncryogenic CdTe or NaI detectors. Results: The initial results demonstrate that a modified version of CCSR can be successfully applied to trabecular bone assessment using a diagnostic x-ray tube with a continuous spectrum in two variations, the FS-BS and the FS-T ratio. When FS-BS is measured, intensity spectra in the forward and backward directions must be collected while FS-T requires only the integral intensity of the scattered and transmitted (T) spectra in the energy region above 40 keV. For both of these methods, forward scattering angles less than or equal to 15° and backward scattering angles greater than or equal to (165°= 180° − 15°) are needed. Conclusions: The authors determined that FS-T is more sensitive to changes in BMD than transmission or absorption alone and that the FS-BS method can yield an absolute measurement of the mean atomic number of the scattering medium, after a correction for path-dependent attenuation. Since this study determined that the FS-T ratio is independent of the incident energy over a broad energy region, it will be possible to apply FS-T to bone densitometry using inexpensive integral photon detectors. The authors believe that, by replacing the radionuclide source with an x-ray tube and the cryogenically cooled HPGe detector with a single solid state CdTe, NaI, or silicon detector or an annular array of detectors, as suggested in this study, the past difficulties of CCSR concerning high radiation exposure, costs, and durations as well as lack of convenience can be overcome and that CCSR could eventually become popular in clinical settings. PMID:22482605

  10. Positronium formation at surfaces and studies towards the production of low energy antihydrogen

    NASA Astrophysics Data System (ADS)

    Cassidy, David Barry

    A magnetically guided slow positron beam has been used to measure positronium formation fractions via spectroscopy of annihilation radiation. Positrons with energies in the range 0-3 keV were implanted into tungsten, copper, magnesium oxide powder and silica aerogel targets at room temperature and at cryogenic temperatures ( 30 K). This was done with and without nitrogen gas condensed on the surface of these materials. The resulting gamma rays were detected by a CsI detector and an associated PC-based spectroscopy system. In most cases studied the measured energy dependence of the positronium fractions was consistent with previous similar work, however, anomalous behaviour was found in some of the data when gas was condensed on metal surfaces. Using the same positron beam initial measurements of positronium energy distributions have been made. This was accomplished using a HPGe detector to measure the Doppler shift of the energy' of the positronium annihilation radiation. This novel technique has not yet been refined and estimates of its potential are reported. A Monte Carlo simulation of the reaction to form antihydrogen by positronium impact upon antiprotons has been undertaken. Total and differential cross sections have been utilised as input to the simulation which models the conditions foreseen in planned antihydrogen formation experiments using antiprotons and positrons held in Penning traps. Thus, predictions of antihydrogen production rates, angular distributions and the variation of the mean antihydrogen temperature as a function of the incident positronium energy have been made.

  11. Gamma decay of pygmy states in 90,94Zr from inelastic scattering of light ions

    NASA Astrophysics Data System (ADS)

    Crespi, F. C. L.; Bracco, A.; Tamii, A.; Blasi, N.; Camera, F.; Wieland, O.; Aoi, N.; Balabanski, D.; Bassauer, S.; Brown, A. S.; Carpenter, M. P.; Carroll, J. J.; Ciemala, M.; Czeszumska, A.; Davies, P. J.; Donaldson, L.; Fang, Y.; Fujita, H.; Gey, G.; Hoang, T. H.; Ichige, N.; Ideguchi, E.; Inoue, A.; Isaak, J.; Iwamoto, C.; Jenkins, D. G.; Jin, O. H.; Klaus, T.; Kobayashi, N.; Koike, T.; Krzysiek, M.; Raju, M. Kumar; Liu, M.; Maj, A.; Montanari, D.; Morris, L.; Noji, S.; Pickstone, S. G.; Savran, D.; Spieker, M.; Steinhilber, G.; Sullivan, C.; Wasilewska, B.; Werner, V.; Yamamoto, T.; Yamamoto, Y.; Zhou, X.; Zhu, S.

    2018-05-01

    We performed experiments to study the low-energy part of the E1 response (Pygmy Dipole Resonance) in 90,94Zr nuclei, by measuring the (p,p’γ) and (α,α’γ) inelastic scattering reactions at energies Ebeam,p = 80 MeV and Ebeam,α = 130 MeV respectively. The inelastically scattered particles were measured by employing the high-resolution spectrometer Grand Raiden. The gamma-rays emitted following the de-excitation of the Zr target nuclei were detected using both the clover type HPGe detectors of the CAGRA array and the large volume LaBr3:Ce scintillation detectors from the HECTOR+ array. Some preliminary results are presented here.

  12. Rapid, autonomous analysis of He spectra I: Overview of the RadID program, user experience, and structure

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gosnell, Thomas B.; Chavez, Joseph R.; Rowland, Mark S.

    2014-02-26

    RadID is a new gamma-ray spectrum analysis program for rapid screening of HPGe gamma-ray data to reveal the presence of radionuclide signatures. It is an autonomous, rule-based heuristic system that can identify well over 200 radioactive sources with particular interest in uranium and plutonium characteristics. It executes in about one second. RadID does not require knowledge of the detector efficiency, the source-to-detector distance, or the geometry of the inspected radiation source—including any shielding. In this first of a three-document series we sketch the RadID program’s origin, its minimal requirements, the user experience, and the program operation.

  13. Study of Natural Radioactivity in Coal Samples of Baganuur Coal Mine, Mongolia

    NASA Astrophysics Data System (ADS)

    Altangerel, M.; Norov, N.; Altangerel, D.

    2009-03-01

    Coal and soil samples from Baganuur Coal Mine (BCM) of Mongolia have been investigated. The activities of 226Ra, 232Th and 40K have been measured by gamma-ray spectrometry using shielded HPGe detector. Contents of natural radionuclide elements (U, Th and K) have been determined. Also the activities and contents of radionuclide of ashes were determined which generated in Thermal Power Plant ♯3 of Ulaanbaatar from coal supplied from BCM.

  14. Investigations of 2β decay of {sup 106}Cd and {sup 58}Ni with HPGe spectrometer OBELIX

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rukhadze, E.; Fajt, L.; Hodák, R.

    2015-08-17

    Investigations of double beta decay processes to excited states of daughter nuclei were performed at the Modane underground laboratory (LSM, France, 4800 m w.e.) using the high sensitivity spectrometer OBELIX [1], which is a common activity of JINR Dubna, IEAP CTU in Prague and LSM. The spectrometer is based on the HPGe detector with the sensitive volume of 600 cm{sup 3} and relative efficiency of 160%. Investigation of resonant neutrino-less double electron capture of {sup 106}Cd was performed with ∼23.2 g of {sup 106}Cd (enrichment of 99.57%) during ∼17 days. The experiment with natural Ni (∼21.7 kg of mass) was also carried out duringmore » ∼47 days. The preliminary experimental limits for 0νEC/EC resonant decay to the excited states of {sup 106}Pd and different modes of β β decay {sup 58}Ni are presented.« less

  15. Metrological tests of a 200 L calibration source for HPGE detector systems for assay of radioactive waste drums.

    PubMed

    Boshkova, T; Mitev, K

    2016-03-01

    In this work we present test procedures, approval criteria and results from two metrological inspections of a certified large volume (152)Eu source (drum about 200L) intended for calibration of HPGe gamma assay systems used for activity measurement of radioactive waste drums. The aim of the inspections was to prove the stability of the calibration source during its working life. The large volume source was designed and produced in 2007. It consists of 448 identical sealed radioactive sources (modules) apportioned in 32 transparent plastic tubes which were placed in a wooden matrix which filled the drum. During the inspections the modules were subjected to tests for verification of their certified characteristics. The results show a perfect compliance with the NIST basic guidelines for the properties of a radioactive certified reference material (CRM) and demonstrate the stability of the large volume CRM-drum after 7 years of operation. Copyright © 2015 Elsevier Ltd. All rights reserved.

  16. Nondestructive Analysis of MET-5 Paint Can at TA35 Building 2 A-Wing Vault

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Desimone, David J.; Vo, Duc Ta

    In Building 2 A-wing vault MET-5 has some drums and other packages they wanted NEN-1 help identifying nondestructively. Measurements using a mechanically cooled portable high-purity germanium HPGe Ortec detective were taken of a paint can container labeled DU-2A to determine if any radioactive material was inside. The HPGe detector measures the gamma rays emitted by radioactive material and displays it as a spectrum. The spectrum is used to identify this radioactive material by using appropriate analysis software and identifying the gamma ray peaks. A paint can container, DU-2A, was analyzed with PeakEasy 4.84 and FRAM 5.2. The FRAM report ismore » shown. The enrichment is 0.091% U235 and 99.907% U238. This material is depleted uranium. The measurement was performed in the near field, and to extract a mass a far field measurement will need to be taken.« less

  17. Aerial Measuring System Sensor Modeling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    R. S. Detwiler

    2002-04-01

    This project deals with the modeling the Aerial Measuring System (AMS) fixed-wing and rotary-wing sensor systems, which are critical U.S. Department of Energy's National Nuclear Security Administration (NNSA) Consequence Management assets. The fixed-wing system is critical in detecting lost or stolen radiography or medical sources, or mixed fission products as from a commercial power plant release at high flying altitudes. The helicopter is typically used at lower altitudes to determine ground contamination, such as in measuring americium from a plutonium ground dispersal during a cleanup. Since the sensitivity of these instruments as a function of altitude is crucial in estimatingmore » detection limits of various ground contaminations and necessary count times, a characterization of their sensitivity as a function of altitude and energy is needed. Experimental data at altitude as well as laboratory benchmarks is important to insure that the strong effects of air attenuation are modeled correctly. The modeling presented here is the first attempt at such a characterization of the equipment for flying altitudes. The sodium iodide (NaI) sensors utilized with these systems were characterized using the Monte Carlo N-Particle code (MCNP) developed at Los Alamos National Laboratory. For the fixed wing system, calculations modeled the spectral response for the 3-element NaI detector pod and High-Purity Germanium (HPGe) detector, in the relevant energy range of 50 keV to 3 MeV. NaI detector responses were simulated for both point and distributed surface sources as a function of gamma energy and flying altitude. For point sources, photopeak efficiencies were calculated for a zero radial distance and an offset equal to the altitude. For distributed sources approximating an infinite plane, gross count efficiencies were calculated and normalized to a uniform surface deposition of 1 {micro}Ci/m{sup 2}. The helicopter calculations modeled the transport of americium-241 ({sup 241}Am) as this is the ''marker'' isotope utilized by the system for Pu detection. The helicopter sensor array consists of 2 six-element NaI detector pods, and the NaI pod detector response was simulated for a distributed surface source of {sup 241}Am as a function of altitude.« less

  18. Measurement of picosecond lifetimes in neutron-rich Xe isotopes

    NASA Astrophysics Data System (ADS)

    Ilieva, S.; Kröll, Th.; Régis, J.-M.; Saed-Samii, N.; Blanc, A.; Bruce, A. M.; Fraile, L. M.; de France, G.; Hartig, A.-L.; Henrich, C.; Ignatov, A.; Jentschel, M.; Jolie, J.; Korten, W.; Köster, U.; Lalkovski, S.; Lozeva, R.; Mach, H.; Mǎrginean, N.; Mutti, P.; Paziy, V.; Regan, P. H.; Simpson, G. S.; Soldner, T.; Thürauf, M.; Ur, C. A.; Urban, W.; Warr, N.

    2016-09-01

    Background: Lifetimes of nuclear excited states in fission fragments have been studied in the past following isotope separation, thus giving access mainly to the fragments' daughters and only to long-lived isomeric states in the primary fragments. For the first time now, short-lived excited states in the primary fragments, produced in neutron-induced prompt fission of 235U and 241Pu, were studied within the EXILL&FATIMA campaign at the intense neutron-beam facility of the Institute Laue-Langevin in Grenoble. Purpose: We aim to investigate the quadrupole collective properties of neutron-rich even-even 138,140,142Xe isotopes lying between the double shell closure N =82 and Z =50 and a deformed region with octupole collectivity. Method: The γ rays emitted from the excited fragments were detected with a mixed array consisting of 8 HPGe EXOGAM Clover detectors (EXILL) and 16 LaBr3(Ce) fast scintillators (FATIMA). The detector system has the unique ability to select the interesting fragment making use of the high resolution of the HPGe detectors and determine subnanosecond lifetimes using the fast scintillators. For the analysis the generalized centroid difference method was used. Results: We show that quadrupole collectivity increases smoothly with increasing neutron number above the closed N =82 neutron shell. Our measurements are complemented by state-of-the-art theory calculations based on shell-model descriptions. Conclusions: The observed smooth increase in quadrupole collectivity is similar to the evolution seen in the measured masses of the xenon isotopic chain and is well reproduced by theory. This behavior is in contrast to higher Z even-even nuclei where abrupt change in deformation occurs around N =90 .

  19. Radioisotope studies of the farmville meteorite using γγ-coincidence spectrometry.

    PubMed

    Howard, Chris; Ferm, Megan; Cesaratto, John; Daigle, Stephen; Iliadis, Christian

    2014-12-01

    Radionuclides are cosmogenically produced in meteorites before they fall to the surface of the Earth. Measurement of the radioactive decay of such nuclides provides a wealth of information on the irradiation conditions of the meteorite fragment, the intensity of cosmic rays in the inner solar system, and the magnetic activity of the Sun. We report here on the detection of (26)Al using a sophisticated spectrometer consisting of a HPGe detector and a NaI(Tl) annulus. It is shown that modern γ-ray spectrometers represent an interesting alternative to other detection techniques. Data are obtained for a fragment of the Farmville meteorite and compared to results from Geant4 simulations. In particular, we report on optimizing the detection sensitivity by using suitable coincidence gates for deposited energy and event multiplicity. We measured an (26)Al activity of 48.5±3.5dpm/kg for the Farmville meteorite, in agreement with previously reported values for other H chondrites. Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. Cross section of the 197Au(n,2n)196Au reaction

    NASA Astrophysics Data System (ADS)

    Kalamara, A.; Vlastou, R.; Kokkoris, M.; Diakaki, M.; Serris, M.; Patronis, N.; Axiotis, M.; Lagoyannis, A.

    2017-09-01

    The 197Au(n,2n)196Au reaction cross section has been measured at two energies, namely at 17.1 MeV and 20.9 MeV, by means of the activation technique, relative to the 27Al(n,α)24Na reference reaction cross section. Quasi-monoenergetic neutron beams were produced at the 5.5 MV Tandem T11/25 accelerator laboratory of NCSR "Demokritos", by means of the 3H(d,n)4He reaction, implementing a new Ti-tritiated target of ˜ 400 GBq activity. The induced γ-ray activity at the targets and reference foils has been measured with HPGe detectors. The cross section for the population of the second isomeric (12-) state m2 of 196Au was independently determined. Auxiliary Monte Carlo simulations were performed using the MCNP code. The present results are in agreement with previous experimental data and with theoretical calculations of the measured reaction cross sections, which were carried out with the use of the EMPIRE code.

  1. Initial Results from the Majorana Demonstrator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Elliott, S. R.; Abgrall, N.; Arnquist, I. J.

    The Majorana Collaboration has assembled an array of high purity Ge detectors to search for neutrinoless double-beta decay in 76Ge with the goal of establishing the required background and scalability of a Ge-based next-generation tonne-scale experiment. The Majorana Demonstrator consists of 44 kg of high-purity Ge (HPGe) detectors (30 kg enriched in 76Ge) with a low-noise p-type point contact (PPC) geometry. The detectors are split between two modules which are contained in a single lead and high-purity copper shield at the Sanford Underground Research Facility in Lead, South Dakota. Following a commissioning run that started in June 2015, the fullmore » detector array has been acquiring data since August 2016. We will discuss the status of the Majorana Demonstrator and initial results from the first physics run; including current background estimates, exotic low-energy physics searches, projections on the physics reach of the Demonstrator, and implications for a tonne-scale Ge based Neutrinoless double-beta decay search.« less

  2. Fluorescent x-ray computed tomography with synchrotron radiation using fan collimator

    NASA Astrophysics Data System (ADS)

    Takeda, Tohoru; Akiba, Masahiro; Yuasa, Tetsuya; Kazama, Masahiro; Hoshino, Atsunori; Watanabe, Yuuki; Hyodo, Kazuyuki; Dilmanian, F. Avraham; Akatsuka, Takao; Itai, Yuji

    1996-04-01

    We describe a new system of fluorescent x-ray computed tomography applied to image nonradioactive contrast materials in vivo. The system operates on the basis of computed tomography (CT) of the first generation. The experiment was also simulated using the Monte Carlo method. The research was carried out at the BLNE-5A bending-magnet beam line of the Tristan Accumulation Ring in Kek, Japan. An acrylic cylindrical phantom containing five paraxial channels of 5 and 4 mm diameters was imaged. The channels were filled with a diluted iodine-based contrast material, with iodine concentrations of 2 mg/ml and 500 (mu) g/ml. Spectra obtained with the system's high purity germanium (HPGe) detector separated clearly the K(alpha ) and K(beta 1) x-ray fluorescent lines, and the Compton scattering. CT images were reconstructed from projections generated by integrating the counts in these spectral lines. The method had adequate sensitivity and detection power, as shown by the experiment and predicted by the simulations, to show the iodine content of the phantom channels, which corresponded to 1 and 4 (mu) g iodine content per pixel in the reconstructed images.

  3. CREPT-MCNP code for efficiency calibration of HPGe detectors with the representative point method.

    PubMed

    Saegusa, Jun

    2008-01-01

    The representative point method for the efficiency calibration of volume samples has been previously proposed. For smoothly implementing the method, a calculation code named CREPT-MCNP has been developed. The code estimates the position of a representative point which is intrinsic to each shape of volume sample. The self-absorption correction factors are also given to make correction on the efficiencies measured at the representative point with a standard point source. Features of the CREPT-MCNP code are presented.

  4. Radiation Templates of Spent Fuel in Casks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vanier, Peter

    BNL and INL propose to perform a scoping study, using heavily collimated gamma and fast neutron detectors, to obtain passive radiation templates of dry storage casks containing spent fuel. The goal is to demonstrate sufficient spatial resolution and sensitivity to detect a missing fuel assembly. Such measurements, combined with detailed modeling and decay corrections should provide confidence that the cask contents have not been altered, despite loss of continuity of knowledge (CoK). The concept relies on the leakage of high energy gammas and neutrons through the shielding of the casks. Tests will emphasize organic scintillators with pulse shape discrimination, butmore » baseline comparisons will be made to high purity germanium (HPGe) and collimated moderated 3He detectors deployed in the same locations. Commercial off-the-shelf (COTS) detectors and data acquisition electronics will be used with custom-built collimators and shielding.« less

  5. A deviation display method for visualising data in mobile gamma-ray spectrometry.

    PubMed

    Kock, Peder; Finck, Robert R; Nilsson, Jonas M C; Ostlund, Karl; Samuelsson, Christer

    2010-09-01

    A real time visualisation method, to be used in mobile gamma-spectrometric search operations using standard detector systems is presented. The new method, called deviation display, uses a modified waterfall display to present relative changes in spectral data over energy and time. Using unshielded (137)Cs and (241)Am point sources and different natural background environments, the behaviour of the deviation displays is demonstrated and analysed for two standard detector types (NaI(Tl) and HPGe). The deviation display enhances positive significant changes while suppressing the natural background fluctuations. After an initialization time of about 10min this technique leads to a homogeneous display dominated by the background colour, where even small changes in spectral data are easy to discover. As this paper shows, the deviation display method works well for all tested gamma energies and natural background radiation levels and with both tested detector systems.

  6. A Test Apparatus for the MAJORANA DEMONSTRATOR Front-end Electronics

    NASA Astrophysics Data System (ADS)

    Singh, Harjit; Loach, James; Poon, Alan

    2012-10-01

    One of the most important experimental programs in neutrino physics is the search for neutrinoless double-beta decay. The MAJORANA collaboration is searching for this rare nuclear process in the Ge-76 isotope using HPGe detectors. Each detector is instrumented with high-performance electronics to read out and amplify the signals. The part of the electronics close to the detectors, consisting of a novel front-end circuit, cables and connectors, is made of radio-pure materials and is exceedingly delicate. In this work a dedicated test apparatus was created to benchmark the performance of the electronics before installation in the experiment. The apparatus was designed for cleanroom use, with fixtures to hold the components without contaminating them, and included the electronics necessary for power and readout. In addition to testing, the station will find longer term use in development of future versions of the electronics.

  7. Skyshine Contribution to Gamma Ray Background Between 0 and 4 MeV

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mitchell, Allison L.; Borgardt, James D.; Kouzes, Richard T.

    2009-08-14

    Natural gamma-ray background is composed of four components; which include cosmic rays, cosmic ray produced atmospheric activity, terrestrial sources, and skyshine from terrestrial sources. Skyshine is radiation scattered from the air above a source that can produce a signal in radiation detection instrumentation. Skyshine has been studied for many years but its contribution to the natural background observed in a detector has not been studied. A large NaI(Tl) detector was used to investigate each of the four components of the natural background using a series of 48-hour measurements and appropriate lead shielding configured to discriminate contributions from each component. Itmore » was found that while the contribution from skyshine decreases rapidly with energy, it represents a significant portion of the background spectrum below ~500keV. A similar campaign of measurements using a HPGe detector is underway.« less

  8. Validation of an advanced analytical procedure applied to the measurement of environmental radioactivity.

    PubMed

    Thanh, Tran Thien; Vuong, Le Quang; Ho, Phan Long; Chuong, Huynh Dinh; Nguyen, Vo Hoang; Tao, Chau Van

    2018-04-01

    In this work, an advanced analytical procedure was applied to calculate radioactivity in spiked water samples in a close geometry gamma spectroscopy. It included MCNP-CP code in order to calculate the coincidence summing correction factor (CSF). The CSF results were validated by a deterministic method using ETNA code for both p-type HPGe detectors. It showed that a good agreement for both codes. Finally, the validity of the developed procedure was confirmed by a proficiency test to calculate the activities of various radionuclides. The results of the radioactivity measurement with both detectors using the advanced analytical procedure were received the ''Accepted'' statuses following the proficiency test. Copyright © 2018 Elsevier Ltd. All rights reserved.

  9. Full-Spectrum-Analysis Isotope ID

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mitchell, Dean J.; Harding, Lee; Thoreson, Gregory G.

    2017-06-28

    FSAIsotopeID analyzes gamma ray spectra to identify radioactive isotopes (radionuclides). The algorithm fits the entire spectrum with combinations of pre-computed templates for a comprehensive set of radionuclides with varying thicknesses and compositions of shielding materials. The isotope identification algorithm is suitable for the analysis of spectra collected by gamma-ray sensors ranging from medium-resolution detectors, such a NaI, to high-resolution detectors, such as HPGe. In addition to analyzing static measurements, the isotope identification algorithm is applied for the radiation search applications. The search subroutine maintains a running background spectrum that is passed to the isotope identification algorithm, and it also selectsmore » temporal integration periods that optimize the responsiveness and sensitivity. Gain stabilization is supported for both types of applications.« less

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ginsz, M.; Duchene, G.; Didierjean, F.

    The state-of-the art gamma-ray spectrometers such as AGATA and GRETA are using position sensitive multi-segmented HPGe crystals. Pulse-shape analysis (PSA) allows to retrieve the localisation of the gamma interactions and to perform gamma-ray tracking within germanium. The precision of the localisation depends on the quality of the pulse-shape database used for comparison. The IPHC laboratory developed a new fast scanning table allowing to measure experimental pulse shapes in the whole volume of any crystal. The results of the scan of an AGATA 36-fold segmented tapered coaxial detector are shown here, 48580 experimental pulse shapes are extracted within 2 weeks ofmore » scanning. These data will contribute to AGATA PSA performances, but have also applications for gamma cameras or Compton-suppressed detectors. (authors)« less

  11. High-spatial resolution and high-spectral resolution detector for use in the measurement of solar flare hard X-rays

    NASA Technical Reports Server (NTRS)

    Desai, U. D.; Orwig, Larry E.

    1988-01-01

    In the areas of high spatial resolution, the evaluation of a hard X-ray detector with 65 micron spatial resolution for operation in the energy range from 30 to 400 keV is proposed. The basic detector is a thick large-area scintillator faceplate, composed of a matrix of high-density scintillating glass fibers, attached to a proximity type image intensifier tube with a resistive-anode digital readout system. Such a detector, combined with a coded-aperture mask, would be ideal for use as a modest-sized hard X-ray imaging instrument up to X-ray energies as high as several hundred keV. As an integral part of this study it was also proposed that several techniques be critically evaluated for X-ray image coding which could be used with this detector. In the area of high spectral resolution, it is proposed to evaluate two different types of detectors for use as X-ray spectrometers for solar flares: planar silicon detectors and high-purity germanium detectors (HPGe). Instruments utilizing these high-spatial-resolution detectors for hard X-ray imaging measurements from 30 to 400 keV and high-spectral-resolution detectors for measurements over a similar energy range would be ideally suited for making crucial solar flare observations during the upcoming maximum in the solar cycle.

  12. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gruetzmacher, Kathleen M.; Bustos, Roland M.; Ferran, Scott G.

    Los Alamos National Laboratory (LANL) uses the Nevada National Security Site (NNSS) as an off-site disposal facility for low-level waste (LLW), including sludge waste. NNSS has issued a position paper that indicates that systems that are not certified by the Carlsbad Field Office (CBFO) for Waste Isolation Pilot Plant (WIPP) disposal of Transuranic (TRU) waste must demonstrate equivalent practices to the CBFO certified systems in order to assign activity concentration values to assayed items without adding in the Total Measurement Uncertainty (TMU) when certifying waste for NNSS disposal. Efforts have been made to meet NNSS requirements to accept sludge wastemore » for disposal at their facility. The LANL LLW Characterization Team uses portable high purity germanium (HPGe) detector systems for the nondestructive assay (NDA) of both debris and sludge LLW. A number of performance studies have been conducted historically by LANL to support the efficacy and quality of assay results generated by the LANL HPGe systems, and, while these detector systems are supported by these performance studies and used with LANL approved procedures and processes, they are not certified by CBFO for TRU waste disposal. Beginning in 2009, the LANL LLW Characterization Team undertook additional NDA measurements of both debris and sludge simulated waste containers to supplement existing studies and procedures to demonstrate full compliance with the NNSS position paper. Where possible, Performance Demonstration Project (PDP) drums were used for the waste matrix and PDP sources were used for the radioactive sources. Sludge drums are an example of a matrix with a uniform distribution of contaminants. When attempting to perform a gamma assay of a sludge drum, it is very important to adequately simulate this uniform distribution of radionuclides in order to accurately model the assay results. This was accomplished by using a spiral radial source tube placement in a sludge drum rather than the standard three source tubes seen in debris PDP drums. Available line sources (Eu-152) were placed in the spiral tubes to further accomplish the desired uniform distribution of radionuclides. The standard PDP drum (PDP matrix drum 005) and PDP sources were used to determine the lower limits of detection (LLD) and TMU. Analysis results for the sludge drum matrix case for two HPGe detectors were tabulated and evaluated. NNSS has accepted the methodology and results of the measurements towards demonstrating equivalence to CBFO certified systems. In conclusion, the WES-WGS and CMR-OPS gamma spectroscopy teams at LANL have defined and performed measurements that serve to establish and demonstrate equivalency with the processes used by CBFO certified NDA systems. The supplemental measurements address four key areas in Appendix A of DOE/WIPP-02-3122: Annual Calibration Confirmation and Performance Check measurements; LLD determination; and TMU definition. For these measurements the containers, matrices and activity loadings are selected to represent items being assayed in real LLW cases. The LLD and the TMU bounding measurements are to be performed one time and will not be required to be repeated in future campaigns. The annual calibration and performance check measurements were performed initially and planned to repeat in annual campaigns in order to maintain NNSS certification. PDP sources and a PDP sludge drum as well as Eu-152 line sources and a spiral sludge drum were used for the measurements. In all cases, the results for accuracy and precision (%R and %RSD, respectively) were within allowable ranges as defined by the WIPP PDP program. LLD (or MDC) results were established for all the ten WIPP reportable radionuclides and U-235, and the MDC for Pu-239 was established in all cases to be well under 100 nCi/g. Useful results for reducing estimated uncertainties were established and an interesting unexpected case of high bias was observed and will be applied toward this end. (authors)« less

  13. Spent Fuel Assay with an Ultra-High Rate HPGe Spectrometer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fast, James; Fulsom, Bryan; Pitts, Karl

    2015-07-01

    Traditional verification of spent nuclear fuel (SNF) includes determination of initial enrichment, burnup and cool down time (IE, BU, CT). Along with neutron measurements, passive gamma assay provides important information for determining BU and CT. Other gamma-ray-based assay methods such as passive tomography and active delayed gamma offer the potential to measure the spatial distribution of fission products and the fissile isotopic concentration of the fuel, respectively. All fuel verification methods involving gamma-ray spectroscopy require that the spectrometers manage very high count rates while extracting the signatures of interest. PNNL has developed new digital filtering and analysis techniques to producemore » an ultra-high rate gamma-ray spectrometer from a standard coaxial high-purity germanium (HPGe) crystal. This 37% relative efficiency detector has been operated for SNF measurements at input count rates of 500-1300 kcps and throughput in excess of 150 kcps. Optimized filtering algorithms preserve the spectroscopic capability of the system even at these high rates. This paper will present the results of both passive and active SNF measurement performed with this system at PNNL. (authors)« less

  14. Investigation of the γ-decay behavior of 52Cr with the γ 3 setup at HIγS

    NASA Astrophysics Data System (ADS)

    Wilhelmy, J.; Erbacher, P.; Gayer, U.; Isaak, J.; Löher, B.; Müscher, M.; Pickstone, S. G.; Pietralla, N.; Ries, P.; Romig, C.; Savran, D.; Spieker, M.; Tornow, W.; Werner, V.; Zilges, A.; Zweidinger, M.

    2018-02-01

    The γ-ray strength function is an important input parameter for the calculation of nucleosynthesis processes. To study the dipole response in more detail, the γ-decay behavior of the fp shell nucleus 52Cr was investigated with the high-efficiency γ 3 setup at the High Intensity γ-ray Source facility at TUNL in Durham, USA. The highly intense quasi mono-energetic γ-ray beam allows for excitations selective in multipolarity (J=1 and J=2) and energy. The γ 3 setup is a multi-detector array consisting of HPGe and LaBr3 detectors with high efficiency and enables the measurement of γ-γ coincidences. Experimental results of 52Cr will be presented and discussed in this contribution.

  15. The search for 0νββ decay with the GERDA experiment: Status and prospects

    NASA Astrophysics Data System (ADS)

    Majorovits, B.

    2015-08-01

    The GERDA experiment is designed to search for neutrinoless double beta decay of 76Ge using HPGe detectors directly immersed into liquid argon. In its first phase the GERDA experiment has yielded a half life limit on this decay of T1/2 0 v>2.1 ṡ1025 . A background model has been developed. It explains the measured spectrum well, taking into account only components with distances to the detectors less then 2 cm. Competitive limits on Majoron accompanied double beta decay have been derived. Phase II of the experiment, now with additional liquid argon veto installed, is presently starting its commissioning phase. First commissioning spectra from calibration measurements are shown, proving that the liquid argon veto leads to a significant reduction of background events.

  16. Orthogonal strip HPGe planar SmartPET detectors in Compton configuration

    NASA Astrophysics Data System (ADS)

    Boston, H. C.; Gillam, J.; Boston, A. J.; Cooper, R. J.; Cresswell, J.; Grint, A. N.; Mather, A. R.; Nolan, P. J.; Scraggs, D. P.; Turk, G.; Hall, C. J.; Lazarus, I.; Berry, A.; Beveridge, T.; Lewis, R.

    2007-10-01

    The evolution of Germanium detector technology over the last decade has lead to the possibility that they can be employed in medical and security imaging. The potential of excellent energy resolution coupled with good position information that Germanium affords removes the necessity for mechanical collimators that would be required in a conventional gamma camera system. By removing this constraint, the overall dose to the patient can be reduced or the throughput of the system can be increased. An additional benefit of excellent energy resolution is that tight gates can be placed on energies from either a multi-lined gamma source or from multi-nuclide sources increasing the number of sources that can be used in medical imaging. In terms of security imaging, segmented Germanium gives directionality and excellent spectroscopic information.

  17. Resistor-less charge sensitive amplifier for semiconductor detectors

    NASA Astrophysics Data System (ADS)

    Pelczar, K.; Panas, K.; Zuzel, G.

    2016-11-01

    A new concept of a Charge Sensitive Amplifier without a high-value resistor in the feedback loop is presented. Basic spectroscopic parameters of the amplifier coupled to a coaxial High Purity Germanium detector (HPGe) are discussed. The amplifier signal input is realized with an n-channel J-FET transistor. The feedback capacitor is discharged continuously by the second, forward biased n-channel J-FET, driven by an RC low-pass filter. Both the analog-with a standard spectroscopy amplifier and a multi-channel analyzer-and the digital-by applying a Flash Analog to Digital Converter-signal readouts were tested. The achieved resolution in the analog and the digital readouts was 0.17% and 0.21%, respectively, at the Full Width at Half Maximum of the registered 60Co 1332.5 keV gamma line.

  18. Half-life of Xe120

    NASA Astrophysics Data System (ADS)

    Phillips, A. A.; Andreoiu, C.; Ball, G. C.; Bandyopadhyay, D.; Behr, J. A.; Chupp, T. E.; Finlay, P.; Garrett, P. E.; Grinyer, G. F.; Hackman, G.; Hayden, M. E.; Hyland, B.; Nuss-Warren, S. R.; Pearson, M. R.; Schumaker, M. A.; Smith, M. B.; Svensson, C. E.; Tardiff, E. R.; Valiente-Dobón, J. J.; Warner, T.

    2006-08-01

    We have measured the half-life of Xe120 using a high-purity germanium (HPGe) detector to monitor the 176, 178, and 762 keV γ rays from Xe120 β+ decay. The result, 46±0.6 min, differs significantly from the value 40±1 min reported by Andersson [Ark. Fys. 28, 37 (1964)]. We have also measured the half-lives of Cs120 and I120 to be 60±0.7 s and 82.1±0.6 min, respectively, both of which are consistent with previous measurements.

  19. High-spin studies: Recent results from the 8π spectrometer

    NASA Astrophysics Data System (ADS)

    Radford, D. C.; Galindo-Uribarri, A.; Hackman, G.; Janzen, V. P.; 8π Collaboration

    1993-05-01

    Selected highlights of recent high-spin nuclear-structure studies with the 8π spectrometer are presented. These include an extensive systematic study of high- j intruder bands in A ˜ 110 Sb, Sn and In nuclei; evidence for hyperdeformation, observed in the reaction 120Sn( 37Cl,px n) populating 152,153Dy; and the observation of a new superdeformed band in the N = 80 nucleus 142Sm. The design of "TRIGAM", a new HPGe-detector array proposed to replace the 8π spectrometer, is also presented.

  20. GRAPhEME: a setup to measure (n, xn γ) reaction cross sections

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Henning, Greg; Bacquias, A.; Capdevielle, O.

    2015-07-01

    Most of nuclear reactor developments are using evaluated data base for numerical simulations. However, the considered databases present still large uncertainties and disagreements. To improve their level of precision, new measurements are needed, in particular for (n, xn) reactions, which are of great importance as they modify the neutron spectrum, the neutron population, and produce radioactive species. The IPHC group started an experimental program to measure (n, xn gamma) reaction cross sections using prompt gamma spectroscopy and neutron energy determination by time of flight. Measurements of (n, xn gamma) cross section have been performed for {sup 235,238}U, {sup 232}Th, {supmore » nat,182,183,184,186}W, {sup nat}Zr. The experimental setup is installed at the neutron beam at GELINA (Geel, Belgium). The setup has recently been upgraded with the addition of a highly segmented 36 pixels planar HPGe detector. Significant efforts have been made to reduce radiation background and electromagnetic perturbations. The setup is equipped with a high rate digital acquisition system. The analysis of the segmented detector data requires a specific procedure to account for cross signals between pixels. An overall attention is paid to the precision of the measurement. The setup characteristic and the analysis procedure will be presented along with the acquisition and analysis challenges. Examples of results and their impact on models will be discussed. (authors)« less

  1. The majorana experiment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rielage, Keith R; Elliott, Steven R; Boswell, Melissa

    2010-12-13

    The MAJORANA Collaboration is assembling an array of HPGe detectors to search for neutrinoless double-beta decay in {sup 76}Ge. Initially, MAJORANA aims to construct a prototype module to demonstrate the potential of a future 1-tonne experiment. The design and potential reach of this prototype DEMONSTRATOR module are presented. Our proposed method uses the well-established technique of searching for neutrinoless double-beta decay in high purity Ge-diode radiation detectors that play both roles of source and detector. The use of P-PC Ge detectors present advances in background rejection and a Significantly lower energy threshold than conventional Ge detector technologies. The lower energymore » threshold opens up a broader and exciting physics program including searches for dark matter and axions concurrent with the double-beta decay search. The DEMONSTRATOR should establish that the backgrounds are low enough to justify scaling to tonne-scale experiment, probe the neutrino effective mass region above 100 meV, and search the low energy region with a sensitivity to dark matter. The DEMONSTRATOR will be sited at the 4850-ft level (4200 m.w.e) of the Sanford Underground Laboratory at Homestake and preparations for construction are currently underway.« less

  2. Characterization of uranium bearing material using x-ray fluorescence and direct gamma-rays measurement techniques

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mujaini, M., E-mail: madihah@uniten.edu.my; Chankow, N.; Yusoff, M. Z.

    2016-01-22

    Uranium ore can be easily detected due to various gamma-ray energies emitted from uranium daughters particularly from {sup 238}U daughters such as {sup 214}Bi, {sup 214}Pb and {sup 226}Ra. After uranium is extracted from uranium ore, only low energy gamma-rays emitted from {sup 235}U may be detected if the detector is placed in close contact to the specimen. In this research, identification and characterization of uranium bearing materials is experimentally investigated using direct measurement of gamma-rays from {sup 235}U in combination with the x-ray fluorescence (XRF) technique. Measurement of gamma-rays can be conducted by using high purity germanium (HPGe) detectormore » or cadmium telluride (CdTe) detector while a {sup 57}Coradioisotope-excited XRF spectrometer using CdTe detector is used for elemental analysis. The proposed technique was tested with various uranium bearing specimens containing natural, depleted and enriched uranium in both metallic and powder forms.« less

  3. a High-Precision Branching-Ratio Measurement for the Superallowed β+ Emitter 74Rb

    NASA Astrophysics Data System (ADS)

    Dunlop, R.; Chagnon-Lessard, S.; Finlay, P.; Garrett, P. E.; Hadinia, B.; Leach, K. G.; Svensson, C. E.; Wong, J.; Ball, G.; Garnsworthy, A. B.; Glister, J.; Hackman, G.; Tardiff, E. R.; Triambak, S.; Williams, S. J.; Leslie, J. R.; Andreoiu, C.; Chester, A.; Cross, D.; Starosta, K.; Yates, S. W.; Zganjar, E. F.

    2013-03-01

    Precision measurements of superallowed Fermi beta decay allow for tests of the Cabibbo-Kobayashi-Maskawa matrix (CKM) unitarity, the conserved vector current hypothesis, and the magnitude of isospin-symmetry-breaking effects in nuclei. A high-precision measurement of the branching ratio for the β+ decay of 74Rb has been performed at the Isotope Separator and ACcelerator (ISAC) facility at TRIUMF. The 8π spectrometer, an array of 20 close-packed HPGe detectors, was used to detect gamma rays emitted following the decay of 74Rb. PACES, an array of 5 Si(Li) detectors, was used to detect emitted conversion electrons, while SCEPTAR, an array of plastic scintillators, was used to detect emitted beta particles. A total of 51γ rays have been identified following the decay of 21 excited states in the daughter nucleus 74Kr.

  4. Analysis of nuclear resonance fluorescence excitation measured with LaBr3(Ce) detectors near 2 MeV

    NASA Astrophysics Data System (ADS)

    Omer, Mohamed; Negm, Hani; Ohgaki, Hideaki; Daito, Izuru; Hayakawa, Takehito; Bakr, Mahmoud; Zen, Heishun; Hori, Toshitada; Kii, Toshiteru; Masuda, Kai; Hajima, Ryoichi; Shizuma, Toshiyuki; Toyokawa, Hiroyuki; Kikuzawa, Nobuhiro

    2013-11-01

    The performance of LaBr3(Ce) to measure nuclear resonance fluorescence (NRF) excitations is discussed in terms of limits of detection and in comparison with high-purity germanium (HPGe) detectors near the 2 MeV region where many NRF excitation levels from special nuclear materials are located. The NRF experiment was performed at the High Intensity γ-ray Source (HIγS) facility. The incident γ-rays, of 2.12 MeV energy, hit a B4C target to excite the 11B nuclei to the first excitation level. The statistical-sensitive non-linear peak clipping (SNIP) algorithm was implemented to eliminate the background and enhance the limits of detection for the spectra measured with LaBr3(Ce). Both detection and determination limits were deduced from the experimental data.

  5. Determination of uranium and thorium using gamma spectrometry: a pilot study

    NASA Astrophysics Data System (ADS)

    Olivares, D. M. M.; Koch, E. S.; Guevara, M. V. M.; Velasco, F. G.

    2018-03-01

    This paper presents the results of a pilot experiment aimed at standardizing procedures for the CPqCTR/UESC Gamma Spectrometry Laboratory (LEG) for the quantification of natural radioactive elements in solid environmental samples. The concentrations of 238U, 232Th and 40K in two sediment matrix belonging to the Caetité region were determined, by using the absolute method with uncertainties about 5%. The results were obtained using gamma spectrometry with a high-resolution p-type HPGe detector. As a closure, the absorbed dose, radium equivalent activity and the annual effective dose were calculated.

  6. Determination of photon emission probabilities for the main gamma-rays of ²²³Ra in equilibrium with its progeny.

    PubMed

    Pibida, L; Zimmerman, B; Fitzgerald, R; King, L; Cessna, J T; Bergeron, D E

    2015-07-01

    The currently published (223)Ra gamma-ray emission probabilities display a wide variation in the values depending on the source of the data. The National Institute of Standards and Technology performed activity measurements on a (223)Ra solution that was used to prepare several sources that were used to determine the photon emission probabilities for the main gamma-rays of (223)Ra in equilibrium with its progeny. Several high purity germanium (HPGe) detectors were used to perform the gamma-ray spectrometry measurements. Published by Elsevier Ltd.

  7. Search for 0νββ-decay with gerda phase II

    NASA Astrophysics Data System (ADS)

    Majorovits, B.

    2018-01-01

    The Gerda experiment is designed to search for neutrinoless double beta decay of 76Ge. From data taken during Phase I of the experiment some knowledge on background contributions important for future experiments could be obtained: limits on the bulk contamination of HPGe with primordial uranium and thorium are presented and first evidence for observation of the decay of the meta-stable state of 77mGe due to neutron capture on 76Ge is discussed. In Phase II of the Gerda experiment 37 HPGe detectors enriched in the isotope 76Ge are deployed into the Gerda cryostat. From non-observation of a peak at 2039 keV a half-life limit on neutrinoless double beta decay of 76Ge of T1/2 > 5.3 . 1025 yr has been obtained. The background rate in the energy region of interest, after pulse shape discrimination and liquid argon veto cuts is in the range of a few Cts//ROI ton yr). This makes Gerda the first 0νββ-experiment that has a background so low that <1 counts are expected in the RoI within the anticipated life time of the experiment.

  8. Measurements of the (n,2n) Reaction Cross Section of 181Ta from 8 to 15 MeV

    NASA Astrophysics Data System (ADS)

    Bhatia, C.; Gooden, M. E.; Tornow, W.; Tonchev, A. P.

    2014-05-01

    The cross section for the reaction 181Ta(n,2n)180Tag was measured from 8 to 15 MeV in small energy steps to resolve inconsistencies in the existing databases. The activation technique was used, and the 93.4 keV γ-ray from the decay of the 180Tag ground state was recorded with a HPGe detector. In addition, the γ-rays from the monitor reactions 27Al(n,α)24Na and 197Au(n,2n)196Au were measured for neutron fluence determination. As a cross check, a calibrated neutron detector was also used. The ENDF/B-VII.1 and TENDL-2011 evaluations are in considerable disagreement with the present data, which in turn agree very well with the majority of the existing data in the 14 MeV energy region.

  9. Analysis techniques for background rejection at the Majorana Demonstrator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cuestra, Clara; Rielage, Keith Robert; Elliott, Steven Ray

    2015-06-11

    The MAJORANA Collaboration is constructing the MAJORANA DEMONSTRATOR, an ultra-low background, 40-kg modular HPGe detector array to search for neutrinoless double beta decay in 76Ge. In view of the next generation of tonne-scale Ge-based 0νββ-decay searches that will probe the neutrino mass scale in the inverted-hierarchy region, a major goal of the MAJORANA DEMONSTRATOR is to demonstrate a path forward to achieving a background rate at or below 1 count/tonne/year in the 4 keV region of interest around the Q-value at 2039 keV. The background rejection techniques to be applied to the data include cuts based on data reduction, pulsemore » shape analysis, event coincidences, and time correlations. The Point Contact design of the DEMONSTRATOR's germanium detectors allows for significant reduction of gamma background.« less

  10. Four-dimensional positron age-momentum correlation

    NASA Astrophysics Data System (ADS)

    Ackermann, Ulrich; Löwe, Benjamin; Dickmann, Marcel; Mitteneder, Johannes; Sperr, Peter; Egger, Werner; Reiner, Markus; Dollinger, Günther

    2016-11-01

    We have performed first four-dimensional age-momentum correlation (4D-AMOC) measurements at a pulsed high intensity positron micro beam and determined the absolute value of the three-dimensional momentum of the electrons annihilating with the positrons in coincidence with the positron age in the sample material. We operated two position sensitive detectors in coincidence to measure the annihilation radiation: a pixelated HPGe-detector and a microchannel plate image intensifier with a CeBr3 scintillator pixel array. The transversal momentum resolution of the 4D-AMOC setup was measured to be about 17 × 10-3 {m}0c (FWHM) and was circa 3.5 times larger than the longitudinal momentum resolution. The total time resolution was 540 ps (FWHM). We measured two samples: a gold foil and a carbon tape at a positron implantation energy of 2 keV. For each sample discrete electron momentum states and their respective positron lifetimes were extracted.

  11. The Prompt Gamma Neutron Activation Analysis Facility at ICN—Pitesti

    NASA Astrophysics Data System (ADS)

    Bǎrbos, D.; Pǎunoiu, C.; Mladin, M.; Cosma, C.

    2008-08-01

    PGNAA is a very widely applicable technique for determining the presence and amount of many elements simultaneously in samples ranging in size from micrograms to many grams. PGNAA is characterized by its capability for nondestructive multi-elemental analysis and its ability to analyse elements that cannot be determined by INAA. By means of this PGNAA method we are able to increase the performace of INAA method. A facility has been developed at Institute for Nuclear Research—Piteşti so that the unique features of prompt gamma-ray neutron activation analysis can be used to measure trace and major elements in samples. The facility is linked at the radial neutron beam tube at ACPR-TRIGA reactor. During the PGNAA—facility is in use the ACPR reactor will be operated in steady-state mode at 250 KW maximum power. The facility consists of a radial beam-port, external sample position with shielding, and induced prompt gamma-ray counting system. Thermal neutron flux with energy lower than cadmium cut-off at the sample position was measured using thin gold foil is: φscd = 1.106 n/cm2/s with a cadmium ratio of:80. The gamma-ray detection system consist of an HpGe detector of 16% efficiency (detector model GC1518) with 1.85 keV resolution capability. The HpGe is mounted with its axis at 90° with respect to the incident neutron beam at distance about 200mm from the sample position. To establish the performance capabilities of the facility, irradiation of pure element or sample compound standards were performed to identify the gama-ray energies from each element and their count rates.

  12. Investigation of FPGA-Based Real-Time Adaptive Digital Pulse Shaping for High-Count-Rate Applications

    NASA Astrophysics Data System (ADS)

    Saxena, Shefali; Hawari, Ayman I.

    2017-07-01

    Digital signal processing techniques have been widely used in radiation spectrometry to provide improved stability and performance with compact physical size over the traditional analog signal processing. In this paper, field-programmable gate array (FPGA)-based adaptive digital pulse shaping techniques are investigated for real-time signal processing. National Instruments (NI) NI 5761 14-bit, 250-MS/s adaptor module is used for digitizing high-purity germanium (HPGe) detector's preamplifier pulses. Digital pulse processing algorithms are implemented on the NI PXIe-7975R reconfigurable FPGA (Kintex-7) using the LabVIEW FPGA module. Based on the time separation between successive input pulses, the adaptive shaping algorithm selects the optimum shaping parameters (rise time and flattop time of trapezoid-shaping filter) for each incoming signal. A digital Sallen-Key low-pass filter is implemented to enhance signal-to-noise ratio and reduce baseline drifting in trapezoid shaping. A recursive trapezoid-shaping filter algorithm is employed for pole-zero compensation of exponentially decayed (with two-decay constants) preamplifier pulses of an HPGe detector. It allows extraction of pulse height information at the beginning of each pulse, thereby reducing the pulse pileup and increasing throughput. The algorithms for RC-CR2 timing filter, baseline restoration, pile-up rejection, and pulse height determination are digitally implemented for radiation spectroscopy. Traditionally, at high-count-rate conditions, a shorter shaping time is preferred to achieve high throughput, which deteriorates energy resolution. In this paper, experimental results are presented for varying count-rate and pulse shaping conditions. Using adaptive shaping, increased throughput is accepted while preserving the energy resolution observed using the longer shaping times.

  13. 235U enrichment determination on UF6 cylinders with CZT detectors

    NASA Astrophysics Data System (ADS)

    Berndt, Reinhard; Mortreau, Patricia

    2018-04-01

    Measurements of uranium enrichment in UF6 transit cylinders are an important nuclear safeguards verification task, which is performed using a non-destructive assay method, the traditional enrichment meter, which involves measuring the count rate of the 186 keV gamma ray. This provides a direct measure of the 235U enrichment. Measurements are typically performed using either high-resolution detectors (Germanium) with e-cooling and battery operation, or portable devices equipped with low resolution detectors (NaI). Despite good results being achieved when measuring Low Enriched Uranium in 30B type cylinders and natural uranium in 48Y type containers using both detector systems, there are situations, which preclude the use of one or both of these systems. The focus of this work is to address some of the recognized limitations in relation to the current use of the above detector systems by considering the feasibility of an inspection instrument for 235U enrichment measurements on UF6 cylinders using the compact and light Cadmium Zinc Telluride (CZT) detectors. In the present work, test measurements were carried out, under field conditions and on full-size objects, with different CZT detectors, in particular for situations where existing systems cannot be used e.g. for stacks of 48Y type containers with depleted uranium. The main result of this study shows that the CZT detectors, actually a cluster of four μCZT1500 micro spectrometers provide as good results as the germanium detector in the ORTEC Micro-trans SPEC HPGe Portable spectrometer, and most importantly in particular for natural and depleted uranium in 48Y cylinders.

  14. Production and characterization of 228Th calibration sources with low neutron emission for GERDA

    NASA Astrophysics Data System (ADS)

    Baudis, L.; Benato, G.; Carconi, P.; Cattadori, C.; De Felice, P.; Eberhardt, K.; Eichler, R.; Petrucci, A.; Tarka, M.; Walter, M.

    2015-12-01

    The GERDA experiment at the Laboratori Nazionali del Gran Sasso (LNGS) searches for the neutrinoless double beta decay of 76Ge. In view of the GERDA Phase II data collection, four new 228Th radioactive sources for the calibration of the germanium detectors enriched in 76Ge have been produced with a new technique, leading to a reduced neutron emission rate from (α, n) reactions. The gamma activities of the sources were determined with a total uncertainty of ~4% using an ultra-low background HPGe detector operated underground at LNGS. The neutron emission rate was determined using a low background LiI(Eu) detector and a 3He counter at LNGS. In both cases, the measured neutron activity is ~10-6 n/(sṡBq), with a reduction of about one order of magnitude with respect to commercially available 228Th sources. Additionally, a specific leak test with a sensitivity to leaks down to ~10 mBq was developed to investigate the tightness of the stainless steel capsules housing the sources after their use in cryogenic environment.

  15. Quantity of 135I released from the AGR-1, AGR-2, and AGR-3/4 experiments and discovery of 131I at the FPMS traps during the AGR-3/4 experiment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Scates, Dawn M.

    2014-09-01

    A series of three Advanced Gas Reactor (AGR) experiments have been conducted in the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL). From 2006 through 2014, these experiments supported the development and qualification of the new U.S. tristructural isotropic (TRISO) particle fuel for Very High Temperature Reactors (VHTR). Each AGR experiment consisted of multiple fueled capsules, each plumbed for independent temperature control using a mix of helium and neon gases. The gas leaving a capsule was routed to individual Fission Product Monitor (FPM) detectors. For intact fuel particles, the TRISO particle coatings provide a substantial barrier to fission productmore » release. However, particles with failed coatings, whether because of a minute percentage of initially defective particles, those which fail during irradiation, or those designed to fail (DTF) particles, can release fission products to the flowing gas stream. Because reactive fission product elements like iodine and cesium quickly deposit on cooler capsule components and piping structures as the effluent gas leaves the reactor core, only the noble fission gas isotopes of Kr and Xe tend to reach FPM detectors. The FPM system utilizes High Purity Germanium (HPGe) detectors coupled with a thallium activated sodium iodide NaI(Tl) scintillator. The HPGe detector provides individual isotopic information, while the NaI(Tl) scintillator is used as a gross count rate meter. During irradiation, the 135mXe concentration reaching the FPM detectors is from both direct fission and by decay of the accumulated 135I. About 2.5 hours after irradiation (ten 15.3 minute 135mXe half lives) the directly produced 135mXe has decayed and only the longer lived 135I remains as a source. Decay systematics dictate that 135mXe will be in secular equilibrium with its 135I parent, such that its production rate very nearly equals the decay rate of the parent, and its concentration in the flowing gas stream will appear to decay with the parent half life. This equilibrium condition enables the determination of the amount of 135I released from the fuel particles by measurement of the 135mXe at the FPM following reactor shutdown. In this paper, the 135I released will be reported and compared to similar releases for noble gases as well as the unexpected finding of 131I deposition from intentional impure gas injection into capsule 11 of experiment AGR 3/4.« less

  16. Summary of the Graduate Mentoring Assistance Program for PNNL PNNL.12.006 (April 2012 – May 31, 2013)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schwantes, Jon M.

    2013-05-01

    Summary of Students and Projects Sarah Bender The possible improvement of the Multi-Isotope Process (MIP) Monitor by the addition of Compton suppression is investigated for this study. The Compton continuum from the dominant 661.7 keV Cs-137 fission product peak obscures lower energy lines which could be used for spectral and multivariate analysis. A novel Compton suppression system which uses fast, room-temperature materials will be developed using simulation. As opposed to the standard high purity germanium (HPGe) detector suppressed using a thallium-doped sodium iodide (NaI(Tl)) guard detector array, cerium-doped lanthanum bromide (LaBr3) will be used as the primary spectroscopic detector. Formore » Sarah’s Master’s degree, she constructed and validated the unsuppressed detector response of the Pennsylvania State University (PSU)-Compton suppression system. For Sarah’s PhD, she is completing that simulation by including the suppressed operation which will be validated with spent fuel samples. She is also going to use the validation of suppressed operation to predict the detector response of a LaBr3 based Compton suppression system. Richard Clark Richard Clark completed his study this FY of a new technique known as Intrinsic Dosimetry. Intrinsic Dosimetry is the method of measuring total absorbed dose received by the walls of a container holding radioactive material. By considering the total absorbed dose received by a container in tandem with the physical characteristics of the radioactive material housed within that container, this method has the potential to provide enhanced pathway information regarding the history of the container and its radioactive contents. The latest in a series of experiments designed to validate and demonstrate this newly developed tool are reported. Kenneth Dayman The MIP Monitor is an online, non-destructive approach to process monitoring in a nuclear fuel reprocessing facility using gamma spectra taken of process streams and multivariate data analysis to detect anomalies in operation. Last year, Mr. Dayman investigated methods to classify spent nuclear fuel according to both reactor type and burn up based on the constituent nuclide activities, which may be used to more accurately calibrate other models in an analysis scheme in order to improve the accuracy and precision of predictions. He is currently writing up his results for publication and has transitioned to another project with Dr. Derrick Haas at PNNL.« less

  17. A system for the measurement of delayed neutrons and gammas from special nuclear materials

    DOE PAGES

    Andrews, M. T.; Corcoran, E. C.; Goorley, J. T.; ...

    2014-11-27

    The delayed neutron counting (DNC) system at the Royal Military College of Canada has been upgraded to accommodate concurrent delayed neutron and gamma measurements. This delayed neutron and gamma counting (DNGC) system uses a SLOWPOKE-2 reactor to irradiate fissile materials before their transfer to a counting arrangement consisting of six ³He and one HPGe detector. The application of this system is demonstrated in an example where delayed neutron and gamma emissions are used in complement to examine ²³³U content and determine fissile mass with an average relative error and accuracy of -2.2 and 1.5 %, respectively.

  18. Standardisation and half-life of 89Zr.

    PubMed

    García-Toraño, E; Peyrés, V; Roteta, M; Mejuto, M; Sánchez-Cabezudo, A; Romero, E

    2018-04-01

    The nuclide 89 Zr is being tested for the labelling of compounds with long blood circulation times. It decays by beta plus emission (22.8%) and by electron capture (77.2%) to 89 Y. Its half-life has been determined by following the decay rate with two measurement systems; an Ionisation Chamber and an HPGe detector. The combination of six results gives a value of T 1/2 = 78.333 (38) h, slightly lower than the DDEP recommended value of 78.42 (13) h. This radionuclide has also been standardised by liquid scintillation counting, 4πγ counting and coincidence techniques. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Mass attenuation coefficient of chromium and manganese compounds around absorption edge.

    PubMed

    Sharanabasappa; Kaginelli, S B; Kerur, B R; Anilkumar, S; Hanumaiah, B

    2009-01-01

    The total mass attenuation coefficient for Potassium dichromate, Potassium chromate and Manganese acetate compounds are measured at different photon energies 5.895, 6.404, 6.490, 7.058, 8.041 and 14.390 keV using Fe-55, Co-57 and 241Am source with Copper target, radioactive sources. The photon intensity is analyzed using a high resolution HPGe detector system coupled to MCA under good geometrical arrangement. The obtained values of mass attenuation coefficient values are compared with theoretical values. This study suggests that measured mass attenuation coefficient values at and near absorption edges differ from the theoretical value by about 5-28%.

  20. Coulomb Excitation of the 64Ni Nucleus and Application of Inverse Kinematics

    NASA Astrophysics Data System (ADS)

    Greaves, Beau; Muecher, Dennis; Ali, Fuad A.; Drake, Tom; Bildstein, Vinzenz; Berner, Christian; Gernhaeuser, Roman; Nowak, K.; Hellgartner, S.; Lutter, R.; Reichert, S.

    2017-09-01

    In this contribution, we present new data on the semi-magic 64Ni nucleus, close to the N =40 harmonic oscillator shell gap. Recent studies suggest a complicated existence of shape coexistence in 68Ni, likely caused by type-II shell evolutions. The region studied here thus might define the ``shore'' of the region of more deformed nuclei in the Island of Inversion below 68Ni. At the Maier-Leibnitz-Laboratory (MLL) in Munich, a beam of 64Ni was excited using Coulomb excitation. The high-granularity MINIBALL HPGe array and a segmented silicon strip detector were used to identify gamma decays in 64Ni. Doppler-shifted attenuation method (DSAM) analysis was applied to the experimental data acquired to resolve the low-lying excited states and acquire a lifetime measurement based on Geant4 simulations of the first excited 2 + state, clarifying the previously conflicting results. Furthermore, we show DSAM data following transfer reactions in inverse kinematics. This new method has the potential to provide insight into tests of ab-initio shell model calculations in the sd-pf shell and for the study of nuclear reaction rates. Supported under NSERC SAPIN-2016-00030.

  1. Measurement of the 235U Induced Fission Gamma-ray Spectrum as an Active Non-destructive Assay of Fresh Nucleear Fuel

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sarnoski, Sarah E.; Fast, James E.; Fulsom, Bryan G.

    2017-07-17

    Non-destructive assay is a powerful tool the International Atomic Energy Agency (IAEA) employs to verify adherence to safeguards agreements. Current IAEA veri- cation techniques for fresh nuclear fuel include passive gamma-ray spectroscopy to determine fuel enrichment. This technique suers from self-shielding and lakes the percision to detect diversion of central fuel rods. The aim of this research is to develop a new, more capable non-destructive analysis technique using active neutron interroga- tion of fuel assemblies and determining the yields of short-lived ssion products from high-resolution gamma-ray spectroscopy using high-purity germanium (HPGe). This paper reports results from irradiation of a onemore » meter tall mock fresh fuel assembly with low enriched uranium (LEU) or depleted uranium (DU) rods using a down-scattered deuterium-tritium (D-T) neutron source. Both prompt and delayed gamma-ray spec- tra were collected as time-stamped list-mode data in a coax detector and without list mode data in a planar strip detector. No dierentiating signatures were observed in the prompt spectra in either detector; however, both detectors observed several short-lived ssion product signatures in LEU and not DU fuel, indicating that this technique has potential for determination of enrichment of fresh fuel assemblies. There were eight unique ssion products observed in the LEU spectra with the coax detector spectra, and three ssion products were observed in the LEU spectra with the strip detector.« less

  2. A high-efficiency HPGe coincidence system for environmental analysis.

    PubMed

    Britton, R; Davies, A V; Burnett, J L; Jackson, M J

    2015-08-01

    The Comprehensive Nuclear-Test-Ban Treaty (CTBT) is supported by a network of certified laboratories which must meet certain sensitivity requirements for CTBT relevant radionuclides. At the UK CTBT Radionuclide Laboratory (GBL15), a high-efficiency, dual-detector gamma spectroscopy system has been developed to improve the sensitivity of measurements for treaty compliance, greatly reducing the time required for each sample. Utilising list-mode acquisition, each sample can be counted once, and processed multiple times to further improve sensitivity. For the 8 key radionuclides considered, Minimum Detectable Activities (MDA's) were improved by up to 37% in standard mode (when compared to a typical CTBT detector system), with the acquisition time required to achieve the CTBT sensitivity requirements reduced from 6 days to only 3. When utilising the system in coincidence mode, the MDA for (60) Co in a high-activity source was improved by a factor of 34 when compared to a standard CTBT detector, and a factor of 17 when compared to the dual-detector system operating in standard mode. These MDA improvements will allow the accurate and timely quantification of radionuclides that decay via both singular and cascade γ emission, greatly enhancing the effectiveness of CTBT laboratories. Crown Copyright © 2015. Published by Elsevier Ltd. All rights reserved.

  3. Cancer Cell Radiobiological Studies Using In-House-Developed α-Particle Irradiator.

    PubMed

    Nilsson, Jenny; Bauden, Monika Posaric; Nilsson, Jonas M; Strand, Sven-Erik; Elgqvist, Jörgen

    2015-11-01

    An α-particle irradiator, enabling high-precision irradiation of cells for in vitro studies, has been constructed. The irradiation source was a (241)Am source, on which well inserts containing cancer cells growing in monolayer were placed. The total radioactivity, uniformity, and α-particle spectrum were determined by use of HPGe detector, Gafchromic dosimetry film, and PIPS detector measurements, respectively. Monte Carlo simulations were used for dosimetry. Three prostate cancer (LNCaP, DU145, PC3) and three pancreatic cancer (Capan-1, Panc-1, BxPC-3) cell lines were irradiated by α-particles to the absorbed doses 0, 0.5, 1, and 2 Gy. For reference, cells were irradiated using (137)Cs to the absorbed doses 0, 1, 2, 4, 6, 8, and 10 Gy. Radiation sensitivity was estimated using a tetrazolium salt-based colorimetric assay with absorbance measurements at 450 nm. The relative biological effectiveness for α-particles relative to γ-irradiation at 37% cell survival for the LNCaP, DU145, PC3, Capan-1, Panc-1, and BxPC-3 cells was 7.9 ± 1.7, 8.0 ± 0.8, 7.0 ± 1.1, 12.5 ± 1.6, 9.4 ± 0.9, and 6.2 ± 0.7, respectively. The results show the feasibility of constructing a desktop α-particle irradiator as well as indicate that both prostate and pancreatic cancers are good candidates for further studies of α-particle radioimmunotherapy.

  4. Photo-Induced depopulation of the 180mTa isomer

    NASA Astrophysics Data System (ADS)

    Bhike, Megha; Krishichayan, Fnu; Tornow, W.

    2015-10-01

    The 180mTa nucleus is the rarest isotope in the universe, existing only in an isomeric state at 77.2 keV (Jπ = 9-) with half-life of greater than 7.1 ×1015 years. The stellar production of this high-spin isomer has been a challenging astrophysical problem. Cross-section measurements for the depopulation of the 180mTa isomer with monoenergetic photon beams of energies 2.5 and 3.1 MeV have been carried out at the HI γS facility. The activated Ta foils of natural abundance and containing 14.4 mg of 180mTa were γ-ray counted at TUNL's low background facility using a 13% planar HPGe detector. A 8'' ×12'' NaI detector in combination with the standard HI γS scintillator paddle system was employed for absolute photon-flux determination. Preliminary results will be discussed, and measurements at lower energies are planned. This work was supported by the U.S. DOE under Grant NO. DE-FG02-97ER41033.

  5. Nuclear Structure Studies in the 132Sn Region: Safe Coulex with Carbon Targets

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Allmond, James M; Stuchbery, Andrew E; Galindo-Uribarri, Alfredo

    2015-01-01

    The collective and single-particle structure of nuclei in the 132Sn region was recently studied by Coulomb excitation and heavy-ion induced transfer reactions using carbon, beryllium, and titanium targets. In particular, Coulomb excitation was used determine a complete set of electromagnetic moments for the first 2 + states and one-neutron transfer was used to probe the purity and evolution of single-neutron states. These recent experiments were conducted at the Holifield Radioactive Ion Beam Facility at ORNL using a CsI-HPGe detector array (BareBall- CLARION) to detect scattered particles and emitted gamma rays from the in-beam reactions. A Bragg-curve detector was used tomore » measure the energy loss of the various beams through the targets and to measure the radioactive beam compositions. A sample of the Coulomb excitation results is presented here with an emphasis placed on 116Sn. In particular, the safe Coulex criterion for carbon targets will be analyzed and discussed.« less

  6. Gamma-ray spectroscopy of 131Sn81 via the (9Be, 8Be γ) reaction

    NASA Astrophysics Data System (ADS)

    Burcher, Sean; Bey, A.; Jones, K.; Ahn, S. H.; Ayres, A.; Schmitt, K. T.; Allmond, J.; Galindo-Urribari, A.; Radford, D. C.; Liang, J. F.; Neseraja, C. D.; Pain, S. D.; Pittman, S. T.; Smith, M. S.; Stracener, D. W.; Varner, R. L.; Bardayan, D. W.; O'Malley, P. D.; Cizewski, J. A.; Howard, M. E.; Manning, B. M.; Garcia Ruiz, R. F.; Kozub, R. L.; Matos, M.; Padilla-Rodal, E.

    2016-09-01

    Nuclear data in the region of the doubly-magic nucleus 132Sn82 is useful for benchmarking nuclear structure theories due to the clean single-particle nature of the nuclear wavefunction near the closed shells. At the Holifield Radioactive Ion Beam Facility (HRIBF) neutron-rich beams in the 132Sn82 region were produced via proton-induced fission of a Uranium-Carbide target. The CLARION array of HPGe detectors was coupled with the HyBall array of CsI detectors to allow for particle-gamma coincidence measurements. The gamma-ray de-excitation of the four lowest lying single-neutron states has been observed for the first time via the (9Be,8Be γ) reaction. The excitation energy of these states have been measured to higher precision than was possible with the previous charged particle measurement. This work was supported in part by the U.S. Department of Energy and the National Science Foundation.

  7. Cosmic-muon intensity measurement and overburden estimation in a building at surface level and in an underground facility using two BC408 scintillation detectors coincidence counting system.

    PubMed

    Zhang, Weihua; Ungar, Kurt; Liu, Chuanlei; Mailhot, Maverick

    2016-10-01

    A series of measurements have been recently conducted to determine the cosmic-muon intensities and attenuation factors at various indoor and underground locations for a gamma spectrometer. For this purpose, a digital coincidence spectrometer was developed by using two BC408 plastic scintillation detectors and an XIA LLC Digital Gamma Finder (DGF)/Pixie-4 software and card package. The results indicate that the overburden in the building at surface level absorbs a large part of cosmic ray protons while attenuating the cosmic-muon intensity by 20-50%. The underground facility has the largest overburden of 39 m water equivalent, where the cosmic-muon intensity is reduced by a factor of 6. The study provides a cosmic-muon intensity measurement and overburden assessment, which are important parameters for analysing the background of an HPGe counting system, or for comparing the background of similar systems. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. Optimized digital filtering techniques for radiation detection with HPGe detectors

    NASA Astrophysics Data System (ADS)

    Salathe, Marco; Kihm, Thomas

    2016-02-01

    This paper describes state-of-the-art digital filtering techniques that are part of GEANA, an automatic data analysis software used for the GERDA experiment. The discussed filters include a novel, nonlinear correction method for ballistic deficits, which is combined with one of three shaping filters: a pseudo-Gaussian, a modified trapezoidal, or a modified cusp filter. The performance of the filters is demonstrated with a 762 g Broad Energy Germanium (BEGe) detector, produced by Canberra, that measures γ-ray lines from radioactive sources in an energy range between 59.5 and 2614.5 keV. At 1332.5 keV, together with the ballistic deficit correction method, all filters produce a comparable energy resolution of 1.61 keV FWHM. This value is superior to those measured by the manufacturer and those found in publications with detectors of a similar design and mass. At 59.5 keV, the modified cusp filter without a ballistic deficit correction produced the best result, with an energy resolution of 0.46 keV. It is observed that the loss in resolution by using a constant shaping time over the entire energy range is small when using the ballistic deficit correction method.

  9. Characterization of HPGe gamma spectrometric detectors systems for Instrumental Neutron Activation Analysis (INAA) at the Colombian Geological Survey

    NASA Astrophysics Data System (ADS)

    Sierra, O.; Parrado, G.; Cañón, Y.; Porras, A.; Alonso, D.; Herrera, D. C.; Peña, M.; Orozco, J.

    2016-07-01

    This paper presents the progress made by the Neutron Activation Analysis (NAA) laboratory at the Colombian Geological Survey (SGC in its Spanish acronym), towards the characterization of its gamma spectrometric systems for Instrumental Neutron Activation Analysis (INAA), with the aim of introducing corrections to the measurements by variations in sample geometry. Characterization includes the empirical determination of the interaction point of gamma radiation inside the Germanium crystal, through the application of a linear model and the use of a fast Monte Carlo N-Particle (MCNP) software to estimate correction factors for differences in counting efficiency that arise from variations in sample density between samples and standards.

  10. K β to K α X-ray intensity ratios and K to L shell vacancy transfer probabilities of Co, Ni, Cu, and Zn

    NASA Astrophysics Data System (ADS)

    Anand, L. F. M.; Gudennavar, S. B.; Bubbly, S. G.; Kerur, B. R.

    2015-12-01

    The K to L shell total vacancy transfer probabilities of low Z elements Co, Ni, Cu, and Zn are estimated by measuring the K β to K α intensity ratio adopting the 2π-geometry. The target elements were excited by 32.86 keV barium K-shell X-rays from a weak 137Cs γ-ray source. The emitted K-shell X-rays were detected using a low energy HPGe X-ray detector coupled to a 16 k MCA. The measured intensity ratios and the total vacancy transfer probabilities are compared with theoretical results and others' work, establishing a good agreement.

  11. Thermal neutron cross-section and resonance integral of the 152Sm(n,γ)153Sm reaction induced by pulsed neutrons

    NASA Astrophysics Data System (ADS)

    Van Do, Nguyen; Khue, Pham Duc; Thanh, Kim Tien; Hien, Nguyen Thi; Kim, Guinyun; Kim, Kwangsoo; Shin, Sung-Gyun; Kye, Yong-Uk; Cho, Moo-Hyun

    2017-10-01

    We measured the thermal neutron cross-section (σ0) and resonance integral (I0) of the 152Sm(n,γ)153Sm reaction relative to that of the 197Au(n,γ)198Au reaction. Sm and Au foils with and without a cadmium cover of 0.5 mm were irradiated with moderated pulsed neutrons produced from the electron linac. The induced activities of the reaction products were determined via high energy resolution HPGe detector. The present results: σ0,Sm =212±8 b and I0,Sm =3.02±0.19 kb are consistent with most of the existing reference data.

  12. Excitation function of alpha-particle-induced reactions on natNi from threshold to 44 MeV

    NASA Astrophysics Data System (ADS)

    Uddin, M. S.; Kim, K. S.; Nadeem, M.; Sudár, S.; Kim, G. N.

    2017-05-01

    Excitation functions of the natNi(α,x)62,63,65Zn, natNi(α,x)56,57Ni and natNi(α,x)56,57,58m+gCo reactions were measured from the respective thresholds to 44MeV using the stacked-foil activation technique. The tests for the beam characterization are described. The radioactivity was measured using HPGe γ-ray detectors. Theoretical calculations on α-particles-induced reactions on natNi were performed using the nuclear model code TALYS-1.8. A few results are new, the others strengthen the database. Our experimental data were compared with results of nuclear model calculations and described the reaction mechanism.

  13. Fast-timing lifetime measurement of 152Gd

    NASA Astrophysics Data System (ADS)

    Wiederhold, J.; Kern, R.; Lizarazo, C.; Pietralla, N.; Werner, V.; Jolos, R. V.; Bucurescu, D.; Florea, N.; Ghita, D.; Glodariu, T.; Lica, R.; Marginean, N.; Marginean, R.; Mihai, C.; Mihai, R.; Mitu, I. O.; Negret, A.; Nita, C.; Olacel, A.; Pascu, S.; Stroe, L.; Toma, S.; Turturica, A.

    2016-10-01

    The lifetime τ (02+) of 152Gd has been measured using fast electronic scintillation timing (FEST) with an array of high-purity germanium (HPGe) and cerium-doped lanthanum bromide (LaBr3) detectors. 152Gd was produced via an (α ,n ) reaction on a gold backed 149Sm target. The measured lifetime of τ (02+) =96 (6 ) ps corresponds to a reduced transition strength of B (E 2 ;02+→21+) =111 (7 ) W.u. and an E 0 transition strength of ρ2(E 0 ) =39 (3 ) ×10-3 to the ground state. This result provides experimental support for the validity of a correlation that would be a novel indicator for a quantum phase transition (QPT).

  14. Surface Alpha Interactions in P-Type Point-Contact HPGe Detectors: Maximizing Sensitivity of 76Ge Neutrinoless Double-Beta Decay Searches

    NASA Astrophysics Data System (ADS)

    Gruszko, Julieta

    Though the existence of neutrino oscillations proves that neutrinos must have non-zero mass, Beyond-the-Standard-Model physics is needed to explain the origins of that mass. One intriguing possibility is that neutrinos are Majorana particles, i.e., they are their own anti-particles. Such a mechanism could naturally explain the observed smallness of the neutrino masses, and would have consequences that go far beyond neutrino physics, with implications for Grand Unification and leptogenesis. If neutrinos are Majorana particles, they could undergo neutrinoless double-beta decay (0nBB), a hypothesized rare decay in which two antineutrinos annihilate one another. This process, if it exists, would be exceedingly rare, with a half-life over 1E25 years. Therefore, searching for it requires experiments with extremely low background rates. One promising technique in the search for 0nBB is the use of P-type point-contact (P-PC) high-purity Germanium (HPGe) detectors enriched in 76Ge, operated in large low-background arrays. This approach is used, with some key differences, by the MAJORANA and GERDA Collaborations. A problematic background in such large granular detector arrays is posed by alpha particles incident on the surfaces of the detectors, often caused by 222Rn contamination of parts or of the detectors themselves. In the MAJORANA DEMONSTRATOR, events have been observed that are consistent with energy-degraded alphas originating near the passivated surface of the detectors, leading to a potential background contribution in the region-of-interest for neutrinoless double-beta decay. However, it is also observed that when energy deposition occurs very close to the passivated surface, high charge trapping occurs along with subsequent slow charge re-release. This leads to both a reduced prompt signal and a measurable change in slope of the tail of a recorded pulse. Here we discuss the characteristics of these events and the development of a filter that can identify the occurrence of this delayed charge recovery (DCR) effect, allowing for the efficient rejection of passivated surface alpha events in analysis. Using a dedicated test-stand called the TUM Upside-down BEGe (TUBE) scanner, we have characterized the response of a P-PC detector like those used in the DEMONSTRATOR to alphas incident on the sensitive surfaces, developing a model for the radial dependence of the energy loss to charge trapping and determining the dominant mechanism behind the delayed charge effect. We have also used these measurements to demonstrate the complementarity of the DCR analysis with the drift-time analysis that is used to identify alpha background candidate events in the GERDA detectors. Using these two methods, we demonstrate the ability to effectively reject all alpha events (to within statistical uncertainty) with only 0.2% bulk event sacrifice. Applying the DCR analysis to the events observed in the MAJORANA DEMONSTRATOR, we find that it reduces the backgrounds in the 0nBB region-of-interest by a factor of 29, increasing the expected experimental sensitivity by a factor of 3 over the lifetime of the DEMONSTRATOR. The results of the dedicated measurements in the TUBE scanner can be used to build a background model for alpha decays in the DEMONSTRATOR; here, we examine two simplified geometric models for the alpha source distribution and find that the observed spectral shape is consistent with alpha events originating in the plastics of the detector units.

  15. New Opportunities in Decay Spectroscopy with the GRIFFIN and DESCANT Arrays

    NASA Astrophysics Data System (ADS)

    Bildstein, V.; Andreoiu, C.; Ball, G. C.; Ballast, T.; Bartlett, C.; Bender, P. C.; Bernier, N.; Bianco, L.; Bishop, D.; Brennan, D.; Bruhn, T.; Cheeseman, A.; Churchman, R.; Ciccone, S.; Davids, B.; Demand, G.; Dillmann, I.; Garnsworthy, A. B.; Garrett, P. E.; Georges, S.; Hackman, G.; Hadinia, B.; Kokke, R.; Krücken, R.; Linn, Y.; Lim, C.; Martin, J.-P.; Miller, D.; Mills, W. J.; Morrison, L. N.; Ohlmann, C. A.; Park, J.; Pearson, C. J.; Pore, J. L.; Rajabali, M. M.; Rand, E. T.; Rizwan, U.; Sarazin, F.; Shaw, B.; Starosta, K.; Svensson, C. E.; Sumithrarachchi, C.; Unsworth, C.; Voss, P.; Wang, Z. M.; Williams, J.; Wong, J.; Wong, S.

    The GRIFFIN (Gamma-Ray Infrastructure For Fundamental Investigations of Nuclei) project is a major upgrade of the decay spectroscopy capabilities at TRIUMF-ISAC. GRIFFIN will replace the 8π spectrometer with an array of up to 16 large-volume HPGe clover detectors and use a state-of-the-art digital data acquisition system. The existing ancillary detector systems that had been developed for 8π, such as the SCEPTAR array for β-tagging, PACES for high-resolution internal conversion electron spectroscopy, and the DANTE array of LaBr3/BaF2 scintillators for fast γ-ray timing, will be used with GRIFFIN. GRIFFIN can also accommodate the new neutron detector array DESCANT (Deuterated Scintillator Array for Neutron Tagging), enabling the study of β-delayed neutron emitters. DESCANT consists of up to 70 detectors, each filled with approximately 2 liters of deuterated benzene, a liquid scintillator that provides pulse-shape discrimination (PSD) capabilities to distinguish between neutrons and γ-rays interacting with the detector. In addition, the anisotropic nature of n-d scattering as compared to the isotropic n-p scattering allows for the determination of the neutron energy spectrum directly from the pulse-height spectrum, complementing the time-of-flight (TOF) information. The installation of GRIFFIN is under way and first experiments are planned for the fall of 2014. The array will be completed in 2015 with the full complement of 16 clovers. DESCANT will be tested coupled with GRIFFIN in spring of 2015.

  16. RESPONSE OF THE GREEK EARLY WARNING SYSTEM REUTER-STOKES IONIZATION CHAMBERS TO TERRESTRIAL AND COSMIC RADIATION EVALUATED IN COMPARISON WITH SPECTROSCOPIC DATA AND TIME SERIES ANALYSIS.

    PubMed

    Leontaris, F; Clouvas, A; Xanthos, S; Maltezos, A; Potiriadis, C; Kiriakopoulos, E; Guilhot, J

    2018-02-01

    The Telemetric Early Warning System Network of the Greek Atomic Energy Commission consists mainly of a network of 24 Reuter-Stokes high-pressure ionization chambers (HPIC) for gamma dose rate measurements and covers all Greece. In the present work, the response of the Reuter-Stokes HPIC to terrestrial and cosmic radiation was evaluated in comparison with spectroscopic data obtained by in situ gamma spectrometry measurements with portable hyper pure Germanium detectors (HPGe), near the Reuter-Stokes detectors and time series analysis. For the HPIC detectors, a conversion factor for the measured absorbed dose rate in air (in nGy h-1) to the total ambient dose equivalent rate Ḣ*(10), due to terrestrial and cosmic component, was deduced by the field measurements. Time series analysis of the mean monthly dose rate (measured by the Reuter-Stokes detector in Thessaloniki, northern Greece, from 2001 to 2016) was performed with advanced statistical methods (Fast Fourier Analysis and Zhao Atlas Marks Transform). Fourier analysis reveals several periodicities (periodogram). The periodogram of the absorbed dose rate in air values was compared with the periodogram of the values measured for the same period (2001-16) and in the same location with a NaI (Tl) detector which in principle is not sensitive to cosmic radiation. The obtained results are presented and discussed. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  17. Measurement of caesium-137 in the human body using a whole body counter

    NASA Astrophysics Data System (ADS)

    Elessawi, Elkhadra Abdulmula

    Gamma radiation in the environment is mainly due to naturally occurring radionuclides. However, there is also a contribution from anthropogenic radionuclides such as 137Cs which originate from nuclear fission processes. Since 1986, the accident at the Chernobyl power plant has been a significant source of artificial environmental radioactivity. In order to assess the radiological impact of these radionuclides, it is necessary to measure their activities in samples drawn from the environment and in plants and animals including human populations. The whole body counter (WBC) at the University Hospital of Wales in Cardiff makes in vivo measurements of gamma emitting radionuclides using a scanning ring of six large-volume thallium-doped sodium iodide (Nal(Tl)) scintillation detectors. In this work the WBC was upgraded by the addition of two high purity germanium (HPGe) detectors. The performance and suitability of the detection systems were evaluated by comparing the detection limits for Cs. Sensitivities were measured using sources of known activity in a water filled anthropomorphic phantom and theoretical minimum detectable count-rates were estimated from phantom background pulse height spectra. The theoretical minimum detectable activity was about 24 Bq for the combination of six Nal(Tl) detectors whereas for the individual HPGe detectors it was 64 Bq and 65 Bq, despite the much improved energy resolution Activities of 137Cs in the human body between 1993 and 2007 were estimated from the background Nal(Tl) spectra of 813 patients and compared with recent measurements in 14 volunteers. The body burden of Cs in Cardiff patients increased from an average of about 60 Bq in the early and mid 1990s to a maximum of about 100 Bq in 2000. By 2007 it had decreased to about 40 Bq. This latter value was similar to that of Cardiff residents at the time of the Chernobyl accident and to that of the volunteers measured in 2007 (51 Bq). However, it was less than the mean activity of Cardiff residents in 1988 (130 Bq) indicating an overall decrease over a period of about 20 years. The variation in the in vivo activity is probably due to complex inter-relationships between a number of factors such as the removal of deposited 137Cs into the sea by rainfall, individual dietary choices, the imposition and removal of restrictions on foodstuffs from Chernobyl-affected areas and travel to countries that suffered greater initial fall-out than the UK.

  18. EXILL—a high-efficiency, high-resolution setup for γ-spectroscopy at an intense cold neutron beam facility

    NASA Astrophysics Data System (ADS)

    Jentschel, M.; Blanc, A.; de France, G.; Köster, U.; Leoni, S.; Mutti, P.; Simpson, G.; Soldner, T.; Ur, C.; Urban, W.; Ahmed, S.; Astier, A.; Augey, L.; Back, T.; Baczyk, P.; Bajoga, A.; Balabanski, D.; Belgya, T.; Benzoni, G.; Bernards, C.; Biswas, D. C.; Bocchi, G.; Bottoni, S.; Britton, R.; Bruyneel, B.; Burnett, J.; Cakirli, R. B.; Carroll, R.; Catford, W.; Cederwall, B.; Celikovic, I.; Cieplicka-Oryńczak, N.; Clement, E.; Cooper, N.; Crespi, F.; Csatlos, M.; Curien, D.; Czerwiński, M.; Danu, L. S.; Davies, A.; Didierjean, F.; Drouet, F.; Duchêne, G.; Ducoin, C.; Eberhardt, K.; Erturk, S.; Fraile, L. M.; Gottardo, A.; Grente, L.; Grocutt, L.; Guerrero, C.; Guinet, D.; Hartig, A.-L.; Henrich, C.; Ignatov, A.; Ilieva, S.; Ivanova, D.; John, B. V.; John, R.; Jolie, J.; Kisyov, S.; Krticka, M.; Konstantinopoulos, T.; Korgul, A.; Krasznahorkay, A.; Kröll, T.; Kurpeta, J.; Kuti, I.; Lalkovski, S.; Larijani, C.; Leguillon, R.; Lica, R.; Litaize, O.; Lozeva, R.; Magron, C.; Mancuso, C.; Ruiz Martinez, E.; Massarczyk, R.; Mazzocchi, C.; Melon, B.; Mengoni, D.; Michelagnoli, C.; Million, B.; Mokry, C.; Mukhopadhyay, S.; Mulholland, K.; Nannini, A.; Napoli, D. R.; Olaizola, B.; Orlandi, R.; Patel, Z.; Paziy, V.; Petrache, C.; Pfeiffer, M.; Pietralla, N.; Podolyak, Z.; Ramdhane, M.; Redon, N.; Regan, P.; Regis, J. M.; Regnier, D.; Oliver, R. J.; Rudigier, M.; Runke, J.; Rzaca-Urban, T.; Saed-Samii, N.; Salsac, M. D.; Scheck, M.; Schwengner, R.; Sengele, L.; Singh, P.; Smith, J.; Stezowski, O.; Szpak, B.; Thomas, T.; Thürauf, M.; Timar, J.; Tom, A.; Tomandl, I.; Tornyi, T.; Townsley, C.; Tuerler, A.; Valenta, S.; Vancraeyenest, A.; Vandone, V.; Vanhoy, J.; Vedia, V.; Warr, N.; Werner, V.; Wilmsen, D.; Wilson, E.; Zerrouki, T.; Zielinska, M.

    2017-11-01

    In the EXILL campaign a highly efficient array of high purity germanium (HPGe) detectors was operated at the cold neutron beam facility PF1B of the Institut Laue-Langevin (ILL) to carry out nuclear structure studies, via measurements of γ-rays following neutron-induced capture and fission reactions. The setup consisted of a collimation system producing a pencil beam with a thermal capture equivalent flux of about 108 n s-1cm-2 at the target position and negligible neutron halo. The target was surrounded by an array of eight to ten anti-Compton shielded EXOGAM Clover detectors, four to six anti-Compton shielded large coaxial GASP detectors and two standard Clover detectors. For a part of the campaign the array was combined with 16 LaBr3:(Ce) detectors from the FATIMA collaboration. The detectors were arranged in an array of rhombicuboctahedron geometry, providing the possibility to carry out very precise angular correlation and directional-polarization correlation measurements. The triggerless acquisition system allowed a signal collection rate of up to 6 × 105 Hz. The data allowed to set multi-fold coincidences to obtain decay schemes and in combination with the FATIMA array of LaBr3:(Ce) detectors to analyze half-lives of excited levels in the pico- to microsecond range. Precise energy and efficiency calibrations of EXILL were performed using standard calibration sources of 133Ba, 60Co and 152Eu as well as data from the reactions 27Al(n,γ)28Al and 35Cl(n,γ)36Cl in the energy range from 30 keV up to 10 MeV.

  19. Experimental Determination of the HPGe Spectrometer Efficiency Calibration Curves for Various Sample Geometry for Gamma Energy from 50 keV to 2000 keV

    NASA Astrophysics Data System (ADS)

    Saat, Ahmad; Hamzah, Zaini; Yusop, Mohammad Fariz; Zainal, Muhd Amiruddin

    2010-07-01

    Detection efficiency of a gamma-ray spectrometry system is dependent upon among others, energy, sample and detector geometry, volume and density of the samples. In the present study the efficiency calibration curves of newly acquired (August 2008) HPGe gamma-ray spectrometry system was carried out for four sample container geometries, namely Marinelli beaker, disc, cylindrical beaker and vial, normally used for activity determination of gamma-ray from environmental samples. Calibration standards were prepared by using known amount of analytical grade uranium trioxide ore, homogenized in plain flour into the respective containers. The ore produces gamma-rays of energy ranging from 53 keV to 1001 keV. Analytical grade potassium chloride were prepared to determine detection efficiency of 1460 keV gamma-ray emitted by potassium isotope K-40. Plots of detection efficiency against gamma-ray energy for the four sample geometries were found to fit smoothly to a general form of ɛ = AΕa+BΕb, where ɛ is efficiency, Ε is energy in keV, A, B, a and b are constants that are dependent on the sample geometries. All calibration curves showed the presence of a "knee" at about 180 keV. Comparison between the four geometries showed that the efficiency of Marinelli beaker is higher than cylindrical beaker and vial, while cylindrical disk showed the lowest.

  20. LArGe: active background suppression using argon scintillation for the Gerda 0ν β β -experiment

    NASA Astrophysics Data System (ADS)

    Agostini, M.; Barnabé-Heider, M.; Budjáš, D.; Cattadori, C.; Gangapshev, A.; Gusev, K.; Heisel, M.; Junker, M.; Klimenko, A.; Lubashevskiy, A.; Pelczar, K.; Schönert, S.; Smolnikov, A.; Zuzel, G.

    2015-10-01

    LArGe is a Gerda low-background test facility to study novel background suppression methods in a low-background environment, for future application in the Gerda experiment. Similar to Gerda, LArGe operates bare germanium detectors submersed into liquid argon (1 m^3, 1.4 tons), which in addition is instrumented with photomultipliers to detect argon scintillation light. The scintillation signals are used in anti-coincidence with the germanium detectors to effectively suppress background events that deposit energy in the liquid argon. The background suppression efficiency was studied in combination with a pulse shape discrimination (PSD) technique using a BEGe detector for various sources, which represent characteristic backgrounds to Gerda. Suppression factors of a few times 10^3 have been achieved. First background data of LArGe with a coaxial HPGe detector (without PSD) yield a background index of (0.12-4.6)× 10^{-2} cts/(keV kg year) (90 % C.L.), which is at the level of Gerda Phase I. Furthermore, for the first time we monitor the natural ^{42}Ar abundance (parallel to Gerda), and have indication for the 2ν β β -decay in natural germanium. These results show the effectivity of an active liquid argon veto in an ultra-low background environment. As a consequence, the implementation of a liquid argon veto in Gerda Phase II is pursued.

  1. Explosives (and other threats) detection using pulsed neutron interrogation and optimized detectors

    NASA Astrophysics Data System (ADS)

    Strellis, Dan A.; Elsalim, Mashal; Gozani, Tsahi

    2011-06-01

    We have previously reported results from a human-portable system using neutron interrogation to detect contraband and explosives. We summarized our methodology for distinguishing threat materials such as narcotics, C4, and mustard gas in the myriad of backgrounds present in the maritime environment. We are expanding our mission for the Domestic Nuclear Detection Office (DNDO) to detect Special Nuclear Material (SNM) through the detection of multiple fission signatures without compromising the conventional threat detection performance. This paper covers our initial investigations into using neutrons from compact pulsed neutron generators via the d(D,n)3He or d(T,n)α reactions with energies of ~2.5 and 14 MeV, respectively, for explosives (and other threats) detection along with a variety of gamma-ray detectors. Fast neutrons and thermal neutrons (after successive collisions) can stimulate the emission of various threat detection signatures. For explosives detection, element-specific gamma-ray signatures via the (n,n'γ) inelastic scattering reaction and the (n,'γ) thermal capture reaction are detected. For SNM, delayed gamma-rays following fission can be measured with the same detector. Our initial trade-off investigations of several gamma-ray detectors types (NaI, CsI, LaBr3, HPGe) for measuring gamma-ray signatures in a pulsed neutron environment for potential application in a human-portable active interrogation system are covered in this paper.

  2. Search for possible solar influences in Ra-226 decays

    NASA Astrophysics Data System (ADS)

    Stancil, Daniel D.; Balci Yegen, Sümeyra; Dickey, David A.; Gould, Chris R.

    Measurements of Ra-226 activity from eight HPGe gamma ray detectors at the NC State University PULSTAR Reactor were analyzed for evidence of periodic variations, with particular attention to annual variations. All measurements were made using the same reference source, and data sets were of varying length taken over the time period from September 1996 through August 2014. Clear evidence of annual variations was observed in data from four of the detectors. Short time periodograms from the data sets suggest temporal variability of both the amplitude and frequency of these variations. The annual variations in two of the data sets show peak values near the first of February, while surprisingly, the annual variations in the other two are roughly out of phase with the first two. Three of the four detectors exhibited annual variations over approximately the same time period. A joint statistic constructed by combining spectra from these three shows peaks approximating the frequencies of solar r-mode oscillations with νR = 11.74 cpy, m = 1, and l = 3, 5, 6. The fact that similar variations were not present in all detectors covering similar time periods rules out variations in activity as the cause, and points to differing sensitivities to unspecified environmental parameters instead. In addition to seasonal variations, the modulation of environmental parameters by solar processes remains a possible explanation of periodogram features, but without requiring new physics.

  3. Low gamma counting for measuring NORM/TENORM with a radon reducing system

    NASA Astrophysics Data System (ADS)

    Paschoa, Anselmo S.

    2001-06-01

    A detection system for counting low levels of gamma radiation was built by upgrading an existing rectangular chamber made of 18 metric tonne of steel fabricated before World War II. The internal walls, the ceiling, and the floor of the chamber are covered with copper sheets. The new detection system consists of a stainless steel hollow cylinder with variable circular apertures in the cylindrical wall and in the base, to allow introduction of a NaI (Tl) crystal, or alternatively, a HPGe detector in its interior. This counting system is mounted inside the larger chamber, which in turn is located in a subsurface air-conditioned room. The access to the subsurface room is made from a larger entrance room through a tunnel plus a glass anteroom to decrease the air-exchange rate. Both sample and detector are housed inside the stainless steel cylinder. This cylinder is filled with hyper pure nitrogen gas, before counting a sample, to prevent radon coming into contact with the detector surface. As a consequence, the contribution of the 214Bi photopeaks to the background gamma spectra is minimized. The reduction of the gamma radiation background near the detector facilitates measurement of naturally occurring radioactive materials (NORM), and/or technologically enhanced NORM (TENORM), which are usually at concentration levels only slightly higher than those typically found in the natural radioactive background.

  4. Recoil distance method lifetime measurements at TRIUMF-ISAC using the TIGRESS Integrated Plunger

    NASA Astrophysics Data System (ADS)

    Chester, A.; Ball, G. C.; Bernier, N.; Cross, D. S.; Domingo, T.; Drake, T. E.; Evitts, L. J.; Garcia, F. H.; Garnsworthy, A. B.; Hackman, G.; Hallam, S.; Henderson, J.; Henderson, R.; Krücken, R.; MacConnachie, E.; Moukaddam, M.; Padilla-Rodal, E.; Paetkau, O.; Pore, J. L.; Rizwan, U.; Ruotsalainen, P.; Shoults, J.; Smallcombe, J.; Smith, J. K.; Starosta, K.; Svensson, C. E.; Van Wieren, K.; Williams, J.; Williams, M.

    2018-02-01

    The TIGRESS Integrated Plunger device (TIP) has been developed for recoil distance method (RDM) lifetime measurements using the TIGRESS array of HPGe γ-ray detectors at TRIUMF's ISAC-II facility. A commissioning experiment was conducted utilizing a 250 MeV 84Kr beam at ≈ 2 × 108 particles per second. The 84Kr beam was Coulomb excited to the 21+ state on a movable 27Al target. A thin Cu foil fixed downstream from the target was used as a degrader. Excited nuclei emerged from the target and decayed by γ-ray emission at a distance determined by their velocity and the lifetime of the 21+ state. The ratio of decays which occur between the target and degrader to those occurring after traversing the degrader changes as a function of the target-degrader separation distance. Gamma-ray spectra at 13 target-degrader separation distances were measured and compared to simulated lineshapes to extract the lifetime. The result of τ = 5 . 541 ± 0 . 013(stat.) ± 0 . 063(sys.) ps is shorter than the literature value of 5 . 84 ± 0 . 18 ps with a reduction in uncertainty by a factor of approximately two. The TIP plunger device, experimental technique, analysis tools, and result are discussed.

  5. Primary standardization of 57Co.

    PubMed

    Koskinas, Marina F; Moreira, Denise S; Yamazaki, Ione M; de Toledo, Fábio; Brancaccio, Franco; Dias, Mauro S

    2010-01-01

    This work describes the method developed by the Nuclear Metrology Laboratory in IPEN, São Paulo, Brazil, for the standardization of a (57)Co radioactive solution. Cobalt-57 is a radionuclide used for calibrating gamma-ray and X-ray spectrometers, as well as a gamma reference source for dose calibrators used in nuclear medicine services. Two 4pibeta-gamma coincidence systems were used to perform the standardization, the first used a 4pi(PC) counter coupled to a pair of 76 mm x 76 mm NaI(Tl) scintillators for detecting gamma-rays, the other one used a HPGe spectrometer for gamma detection. The measurements were performed by selecting a gamma-ray window comprising the (122 keV+136 keV) total absorption energy peaks in the NaI(Tl) and selecting the total absorption peak of 122 keV in the germanium detector. The electronic system used the TAC method developed at LMN for registering the observed events. The methodology recently developed by the LMN for simulating all detection processes in a 4pibeta-gamma coincidence system, by means of the Monte Carlo technique, was applied and the behavior of extrapolation curve compared to experimental data. The final activity obtained by the Monte Carlo calculation agrees with the experimental results within the experimental uncertainty. Copyright 2009 Elsevier Ltd. All rights reserved.

  6. A Multi-Contact, Low Capacitance HPGe Detector for High Rate Gamma Spectroscopy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cox, Christopher

    2014-12-04

    The detection, identification and non-destructive assay of special nuclear materials and nuclear fission by-products are critically important activities in support of nuclear non-proliferation programs. Both national and international nuclear safeguard agencies recognize that current accounting methods for spent nuclear fuel are inadequate from a safeguards perspective. Radiation detection and analysis by gamma-ray spectroscopy is a key tool in this field, but no instrument exists that can deliver the required performance (energy resolution and detection sensitivity) in the presence of very high background count rates encountered in the nuclear safeguards arena. The work of this project addresses this critical need bymore » developing a unique gamma-ray detector based on high purity germanium that has the previously unachievable property of operating in the 1 million counts-per-second range while achieving state-of-the-art energy resolution necessary to identify and analyze the isotopes of interest. The technical approach was to design and fabricate a germanium detector with multiple segmented electrodes coupled to multi-channel high rate spectroscopy electronics. Dividing the germanium detector’s signal electrode into smaller sections offers two advantages; firstly, the energy resolution of the detector is potentially improved, and secondly, the detector is able to operate at higher count rates. The design challenges included the following; determining the optimum electrode configuration to meet the stringent energy resolution and count rate requirements; determining the electronic noise (and therefore energy resolution) of the completed system after multiple signals are recombined; designing the germanium crystal housing and vacuum cryostat; and customizing electronics to perform the signal recombination function in real time. In this phase I work, commercial off-the-shelf electrostatic modeling software was used to develop the segmented germanium crystal geometry, which underwent several iterations before an optimal electrode configuration was found. The model was tested and validated against real-world measurements with existing germanium detectors. Extensive modeling of electronic noise was conducted using established formulae, and real-world measurements were performed on candidate front-end electronic components. This initial work proved the feasibility of the design with respect to expected high count rate and energy resolution performance. Phase I also delivered the mechanical design of the detector housing and vacuum cryostat to be built in Phase II. Finally, a Monte Carlo simulation was created to show the response of the complete design to a Cs-137 source. This development presents a significant advance for nuclear safeguards instrumentation with increased speed and accuracy of detection and identification of special nuclear materials. Other significant applications are foreseen for a gamma-ray detector that delivers high energy resolution (1keV FWHM noise) at high count rate (1 Mcps), especially in the areas of physics research and materials analysis.« less

  7. An accurate redetermination of the 118Sn binding energy

    NASA Astrophysics Data System (ADS)

    Borzakov, S. B.; Chrien, R. E.; Faikow-Stanczyk, H.; Grigoriev, Yu. V.; Panteleev, Ts. Ts.; Pospisil, S.; Smotritsky, L. M.; Telezhnikov, S. A.

    2002-03-01

    The energy of well-known strong γ line from 198Au, the "gold standard", has been modified in the light of new adjustments in the fundamental constants and the value of 411.80176(12) keV was determined, which is 0.29 eV lower than the latest 1999 value. An energy calibration procedure for determining the neutron binding energy, Bn, from complicated (n, γ) spectra has been developed. A mathematically simple minimization function consisting only of terms having as parameters the coefficients of the energy calibration curve (polynomial) is used. A priori information about the relationships among the energies of different peaks on the spectrum is taken into account by a Monte-Carlo simulation. The procedure was used in obtaining Bn for 118Sn. The γ-ray spectrum from thermal neutron radiative capture by 117Sn has been measured on the IBR-2 pulsed reactor. γ-rays were detected by a 72 cm 3 HPGe detector. For a better determination of Bn it was important to determine Bn for 64Cu. This value was obtained from two γ-spectra. One spectrum was measured on the IBR-2 by the same detector. The other spectrum was measured with a pair spectrometer at the Brookhaven High Flux Beam Reactor. From these two spectra, Bn for 64Cu was determined to be equal to 7915.52(8) keV. This result essentially differs from the previous value of 7915.96(11) keV. The mean value of the two most precise results of the Bn for 118Sn, was determined to be 9326.35(9) keV. The Bn for 57Fe was determined to be 7646.08(9) keV.

  8. γγ coincidence spectrometer for instrumental neutron-activation analysis

    NASA Astrophysics Data System (ADS)

    Tomlin, B. E.; Zeisler, R.; Lindstrom, R. M.

    2008-05-01

    Neutron-activation analysis (NAA) is an important technique for the accurate and precise determination of trace and ultra-trace elemental compositions. The application of γγ coincidence counting to NAA in order to enhance specificity was first explored over 40 years ago but has not evolved into a regularly used technique. A γγ coincidence spectrometer has been constructed at the National Institute of Standards and Technology, using two HPGe γ-ray detectors and an all-digital data-acquisition system, for the purpose of exploring coincidence NAA and its value in characterizing reference materials. This paper describes the initial evaluation of the quantitative precision of coincidence counting versus singles spectrometry, based upon a sample of neutron-irradiated bovine liver material.

  9. Measurement of natural radionuclides in phosphgypsum using an anti-cosmic gamma-ray spectrometer.

    PubMed

    Ferreux, Laurent; Moutard, Gérard; Branger, Thierry

    2009-05-01

    Gamma-ray spectrometry measurements have been carried out to determine the activity of natural radionuclides in a phosphogypsum sample included in a specific tight container. The gamma spectrometer includes an N-type coaxial high-purity germanium (HPGe) detector equipped with an anti-cosmic system. This measurement required the determination of linear attenuation coefficients of phosphogypsum to calculate self-absorption correction between efficiency calibration conditions and measurement ones. The results are given for the three natural chains and for (40)K, in term of specific activity/g of dry material, ranging from a few Bq kg(-1) to a few hundreds Bq kg(-1). The equilibrium within the different families and the (235)U/(238)U ratio are discussed.

  10. New low-spin states of 122Xe observed via high-statistics β-decay of 122Cs

    NASA Astrophysics Data System (ADS)

    Jigmeddorj, B.; Garrett, P. E.; Andreoiu, C.; Ball, G. C.; Bruhn, T.; Cross, D. S.; Garnsworthy, A. B.; Hadinia, B.; Moukaddam, M.; Park, J.; Pore, J. L.; Radich, A. J.; Rajabali, M. M.; Rand, E. T.; Rizwan, U.; Svensson, C. E.; Voss, P.; Wang, Z. M.; Wood, J. L.; Yates, S. W.

    2018-05-01

    Excited states of 122Xe were studied via the β+/EC decay of 122Cs with the 8π γ-ray spectrometer at the TRIUMF-ISAC facility. Compton-suppressed HPGe detectors were used for measurements of γ-ray intensities, γγ coincidences, and γ-γ angular correlations. Two sets of data were collected to optimize the decays of the ground (21.2 s) and isomeric (3.7 min) states of 122Cs. The data collected have enabled the observation of about 505 new transitions and about 250 new levels, including 51 new low-spin states. Spin assignments have been made for 58 low-spin states based on the deduced β-decay feeding and γ-γ angular correlation analyses.

  11. K{sub β} to K{sub α} X-ray intensity ratios and K to L shell vacancy transfer probabilities of Co, Ni, Cu, and Zn

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Anand, L. F. M.; Gudennavar, S. B., E-mail: shivappa.b.gudennavar@christuniversity.in; Bubbly, S. G.

    The K to L shell total vacancy transfer probabilities of low Z elements Co, Ni, Cu, and Zn are estimated by measuring the K{sub β} to K{sub α} intensity ratio adopting the 2π-geometry. The target elements were excited by 32.86 keV barium K-shell X-rays from a weak {sup 137}Cs γ-ray source. The emitted K-shell X-rays were detected using a low energy HPGe X-ray detector coupled to a 16 k MCA. The measured intensity ratios and the total vacancy transfer probabilities are compared with theoretical results and others’ work, establishing a good agreement.

  12. Characterization of HPGe gamma spectrometric detectors systems for Instrumental Neutron Activation Analysis (INAA) at the Colombian Geological Survey

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sierra, O., E-mail: osierra@sgc.gov.co; Parrado, G., E-mail: gparrado@sgc.gov.co; Cañón, Y.

    This paper presents the progress made by the Neutron Activation Analysis (NAA) laboratory at the Colombian Geological Survey (SGC in its Spanish acronym), towards the characterization of its gamma spectrometric systems for Instrumental Neutron Activation Analysis (INAA), with the aim of introducing corrections to the measurements by variations in sample geometry. Characterization includes the empirical determination of the interaction point of gamma radiation inside the Germanium crystal, through the application of a linear model and the use of a fast Monte Carlo N-Particle (MCNP) software to estimate correction factors for differences in counting efficiency that arise from variations in samplemore » density between samples and standards.« less

  13. Natural radioactivity in soil in the Baluchistan province of Pakistan.

    PubMed

    Mujahid, S A; Hussain, S

    2010-08-01

    The measurements of natural radioactivity and the assessment of radiological hazards in the soil samples of Baluchistan province of Pakistan have been carried out using HPGe detector. The soil gas radon activities in these areas have also been measured using lucas cell technique. The measured activities of (226)Ra, (232)Th and (40)K were found in the range of 15-27, 20-37 and 328-648 Bq kg(-1), respectively. The calculated absorbed dose rate in air and the annual effective dose were in the range of 35-59 nGy h(-1) and 0.17-0.29 mSv, respectively. Radon activity in the soil gas was found in the range of 357-2476 Bq m(-3).

  14. Direct measurement of beta-delayed neutron emission at and beyond doubly-magic 78Ni

    NASA Astrophysics Data System (ADS)

    Yokoyama, Rin; Briken Collaboration Collaboration

    2017-09-01

    An experiment aiming to measure the beta-neutron-gamma decay properties of nuclei around 78Ni produced by in-flight fission of a 238U beam at 345 MeV/u and selected by means of BigRIPS was recently performed using the BRIKEN setup. The BRIKEN detector is composed of the AIDA implantation-decay array as well as 140 3He tubes and 2 HPGe clovers. The counting efficiency of a single beta-delayed neutron (β1 n) is above 60. National Nuclear Security Administration under the Stewardship Sci- ence Academic Alliances program through DOE Award No. DE- NA0002132 and the Office of Nuclear Physics, U.S. Department of Energy under Award No. DE-FG02-96ER40983.

  15. Measurement of low radioactivity background in a high voltage cable by high resolution inductively coupled plasma mass spectrometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vacri, M. L. di; Nisi, S.; Balata, M.

    2013-08-08

    The measurement of naturally occurring low level radioactivity background in a high voltage (HV) cable by high resolution inductively coupled plasma mass spectrometry (HR ICP MS) is presented in this work. The measurements were performed at the Chemistry Service of the Gran Sasso National Laboratory. The contributions to the radioactive background coming from the different components of the heterogeneous material were separated. Based on the mass fraction of the cable, the whole contamination was calculated. The HR ICP MS results were cross-checked by gamma ray spectroscopy analysis that was performed at the low background facility STELLA (Sub Terranean Low Levelmore » Assay) of the LNGS underground lab using HPGe detectors.« less

  16. Unattended Radiation Sensor Systems for Remote Terrestrial Applications and Nuclear Nonproliferation

    NASA Astrophysics Data System (ADS)

    van den Berg, Lodewijk; Proctor, Alan E.; Pohl, Ken R.; Bolozdynya, Alex; De Vito, Raymond

    2002-10-01

    The design of instrumentation for remote sensing presents special requirements in the areas of power consumption, long-term stability, and compactness. At the same time, the high sensitivity and resolution of the devices needs to be preserved. This paper will describe several instruments suitable for remote sensing developed under the sponsorship of the Defense Threat Reduction Agency (DTRA). The first is a system consisting of a mechanical cryocooler coupled with a high-purity germanium (HPGe) detector. The system is portable and can be operated for extended periods of time at remote locations without servicing. The second is a hand-held radiation intensity meter with high sensitivity that can operate for several months on two small batteries. Intensity signals above a set limit can be transmitted to a central monitoring station by cable or radio transmission. The third is a small module incorporating one or more high resolution mercuric iodide detectors and front end electronics. This unit can be operated using standard electronic systems, or it can be connected to a separately designed, pocket-size module that can provide power to any detector system and can process detector signals. It incorporates a shaping amplifier, a multichannel analyzer, and gated integrator electronics to process the slow signal pulses generated by room temperature solid state detectors. The fourth is a high pressure xenon (HPXe) ionization chamber filled with very pure xenon gas at high pressure, so that the efficiency and spectral resolution are increased above the normally available gas-filled tubes. The performance of these systems will be described and discussed.

  17. A system to measure isomeric state half-lives in the 10 ns to 10 μs range

    NASA Astrophysics Data System (ADS)

    Toufen, D. L.; Allegro, P. R. P.; Medina, N. H.; Oliveira, J. R. B.; Cybulska, E. W.; Seale, W. A.; Linares, R.; Silveira, M. A. G.; Ribas, R. V.

    2014-07-01

    The Isomeric State Measurement System (SISMEI) was developed to search for isomeric nuclear states produced by fusion-evaporation reactions. The SISMEI consists of 10 plastic phoswich telescopes, two lead shields, one NaI(Tl) scintillation detector, two Compton suppressed HPGe γ-ray detectors, and a cone with a recoil product catcher. The new system was tested at the 8 UD Pelletron tandem accelerator of the University of São Paulo with the measurement of two known isomeric states: 54Fe, 10+ state (E = 6527.1 (11) keV, T1/2 = 364(7) ns) and the 5/2+ state of 19F (E = 197.143 (4) keV, T1/2 = 89.3 (10) ns). The results indicate that the system is capable of identifying delayed transitions, of measuring isomeric state lifetimes, and of identifying the feeding transitions of the isomeric state through the delayed γ-γ coincidence method. The measured half-life for the 10+ state was T1/2 = 365(14) ns and for the 5/2+ state, 100(36) ns.

  18. A system to measure isomeric state half-lives in the 10 ns to 10 μs range.

    PubMed

    Toufen, D L; Allegro, P R P; Medina, N H; Oliveira, J R B; Cybulska, E W; Seale, W A; Linares, R; Silveira, M A G; Ribas, R V

    2014-07-01

    The Isomeric State Measurement System (SISMEI) was developed to search for isomeric nuclear states produced by fusion-evaporation reactions. The SISMEI consists of 10 plastic phoswich telescopes, two lead shields, one NaI(Tl) scintillation detector, two Compton suppressed HPGe γ-ray detectors, and a cone with a recoil product catcher. The new system was tested at the 8 UD Pelletron tandem accelerator of the University of São Paulo with the measurement of two known isomeric states: (54)Fe, 10(+) state (E = 6527.1 (11) keV, T(1/2) = 364(7) ns) and the 5/2(+) state of (19)F (E = 197.143 (4) keV, T(1/2) = 89.3 (10) ns). The results indicate that the system is capable of identifying delayed transitions, of measuring isomeric state lifetimes, and of identifying the feeding transitions of the isomeric state through the delayed γ-γ coincidence method. The measured half-life for the 10(+) state was T(1/2) = 365(14) ns and for the 5/2(+) state, 100(36) ns.

  19. White sand potentially suppresses radon emission from uranium tailings

    NASA Astrophysics Data System (ADS)

    Abdel Ghany, H. A.; El Aassy, Ibrahim E.; Ibrahim, Eman M.; Gamil, S. H.

    2018-03-01

    Uranium tailings represent a huge radioactive waste contaminant, where radon emanation is considered a major health hazard. Many trials have been conducted to minimize radon exhalation rate by using different covering materials. In the present work, three covering materials, commonly available in the local environment, (kaolin, white sand and bentonite) have been used with different thickness 10, 15, and 20 mm). 238U, 232Th, 40K and the radon exhalation rate were measured by using gamma spectrometry with a Hyper Pure Germanium (HPGe) detector and solid state nuclear track detectors (CR-39). Radon exhalation rate, calculated before and after covering, ranged from 2.80 ± 0.14 to 4.20 ± 0.21 Bq m-2 h-1, and from 0.30 ± 0.01 to 4.00 ± 0.20 Bq m-2 h-1, respectively. Also, the attenuation coefficients of different covering materials and radon emanation were calculated. The obtained results demonstrate that covering of uranium tailings by kaolin, white sand and bentonite has potentially minimized both the radon exhalation rate and the corresponding internal doses.

  20. Radiological maps for Trabzon, Turkey.

    PubMed

    Kurnaz, A; Kucukomeroglu, B; Damla, N; Cevik, U

    2011-04-01

    The activity concentrations and absorbed gamma dose rates due to primordial radionuclides and (137)Cs have been ascertained in 222 soil samples in 18 counties of the Trabzon province of Turkey using a HPGe detector. The mean activity concentrations of (238)U, (232)Th, (40)K and (137)Cs in soil samples were 41, 35, 437 and 21 Bq kg(-1), respectively. Based on the measured concentrations of these radionuclides, the mean absorbed gamma dose in air was calculated as 59 nGy h(-1) and hence, the mean annual effective dose due to terrestrial gamma radiation was calculated as 72 μSv y(-1). In addition, outdoor in situ gamma dose rate (D) measurements were performed in the same 222 locations using a portable NaI detector and the annual effective dose was calculated to be 66 μSv y(-1) from these results. The results presented in this study are compared with other parts of Turkey. Radiological maps of the Trabzon province were composed using the results obtained from the study. Copyright © 2011 Elsevier Ltd. All rights reserved.

  1. Optimal measurement counting time and statistics in gamma spectrometry analysis: The time balance

    NASA Astrophysics Data System (ADS)

    Joel, Guembou Shouop Cebastien; Penabei, Samafou; Maurice, Ndontchueng Moyo; Gregoire, Chene; Jilbert, Nguelem Mekontso Eric; Didier, Takoukam Serge; Werner, Volker; David, Strivay

    2017-01-01

    The optimal measurement counting time for gamma-ray spectrometry analysis using HPGe detectors was determined in our laboratory by comparing twelve hours measurement counting time at day and twelve hours measurement counting time at night. The day spectrum does not fully cover the night spectrum for the same sample. It is observed that the perturbation come to the sun-light. After several investigations became clearer: to remove all effects of radiation from outside (earth, the sun, and universe) our system, it is necessary to measure the background for 24, 48 or 72 hours. In the same way, the samples have to be measured for 24, 48 or 72 hours to be safe to be purified the measurement (equality of day and night measurement). It is also possible to not use the background of the winter in summer. Depend on to the energy of radionuclide we seek, it is clear that the most important steps of a gamma spectrometry measurement are the preparation of the sample and the calibration of the detector.

  2. Evaluation of Multi-Channel ADCs for Gamma-Ray Spectroscopy

    NASA Astrophysics Data System (ADS)

    Tan, Hui; Hennig, Wolfgang; Walby, Mark D.; Breus, Dimitry; Harris, Jackson

    2013-04-01

    As nuclear physicists increasingly design large scale experiments with hundreds or thousands of detector channels, there are growing needs for high density readout electronics with good timing and energy resolution that at the same time offer lower cost per channel compared to existing commercial solutions. Recent improvements in the design of commercial analog to digital converters (ADCs) have resulted in a variety of multi-channel ADCs that are natural choice for designing such high density readout modules. However, multi-channel ADCs typically are designed for medical imaging/ultrasound applications and therefore are not rated for their spectroscopic characteristics. In this work, we evaluated the gamma-ray spectroscopic performance of several multi-channel ADCs, including their energy resolution, nonlinearity, and timing resolution. Some of these ADCs demonstrated excellent energy resolution, 2.66% FWHM at 662 keV with a LaBr3 or 1.78 keV FWHM at 1332.5 keV with a high purity germanium (HPGe) detector, and sub-nanosecond timing resolution with LaBr 3. We present results from these measurements to illustrate their suitability for gamma-ray spectroscopy.

  3. Study of astrophysical α +22 Ne reaction using alpha transfer with TIARA and MDM spectrometer

    NASA Astrophysics Data System (ADS)

    Ota, Shuya; Christian, Gregory A.; Bennett, Eames B.; Jayatissa, Heshani; Hooker, Joshua; Hunt, Curtis; Magana, Cordero; Rogachev, Grigory; Saastamoinen, Antti; Upadhyayula, Sriteja; Catford, Wilton N.; Hallam, Sam; Lotay, Gavin; Mouhkaddam, Mohamad; Wilkinson, Ryan

    2017-09-01

    In core He burning and C-shell burning of massive stars, the 22Ne(α,n)25Mg reaction is considered to be a main neutron source driving the synthesis of nuclides in the A =60-90 mass range during the s process. While a variety of attempts to experimentally determine the rate for this reaction at the Gamow window corresponding to s process temperatures have been made either through direct 22Ne(α,n)25Mg measurements or indirect measurements, uncertainties of some resonance parameters in 26Mg has remained a longstanding problem. To address this problem, we performed an experiment using the 6Li(22Ne,26Mg) d α -transfer reaction at K150 cyclotron of Texas A&M University. A 6LiF target was bombarded with a 7 MeV/u 22Ne beam. Deuterons, gamma-rays, and recoil Mg ions were detected in coincidence using a large Si detector array, TIARA, HPGe clover detectors, and an MDM spectrometer backed by an ionization chamber, respectively. Preliminary data from the experiment will be presented.

  4. Delayed gamma-ray spectroscopy with lanthanum bromide detector for non-destructive assay of nuclear material

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Favalli, Andrea; Iliev, Metodi; Ianakiev, Kiril

    High-energy delayed γ-ray spectroscopy is a potential technique for directly assaying spent fuel assemblies and achieving the safeguards goal of quantifying nuclear material inventories for spent fuel handling, interim storage, reprocessing facilities, repository sites, and final disposal. Requirements for the γ-ray detection system, up to ~6 MeV, can be summarized as follows: high efficiency at high γ-ray energies, high energy resolution, good linearity between γ-ray energy and output signal amplitude, ability to operate at very high count rates, and ease of use in industrial environments such as nuclear facilities. High Purity Germanium Detectors (HPGe) are the state of the artmore » and provide excellent energy resolution but are limited in their count rate capability. Lanthanum Bromide (LaBr 3) scintillation detectors offer significantly higher count rate capabilities at lower energy resolution. Thus, LaBr 3 detectors may be an effective alternative for nuclear spent-fuel applications, where count-rate capability is a requirement. This paper documents the measured performance of a 2” (length) × 2” (diameter) of LaBr3 scintillation detector system, coupled to a negatively biased PMT and a tapered active high voltage divider, with count-rates up to ~3 Mcps. An experimental methodology was developed that uses the average current from the PMT’s anode and a dual source method to characterize the detector system at specific very high count rate values. Delayed γ-ray spectra were acquired with the LaBr 3 detector system at the Idaho Accelerator Center, Idaho State University, where samples of ~3g of 235U were irradiated with moderated neutrons from a photo-neutron source. Results of the spectroscopy characterization and analysis of the delayed γ-ray spectra acquired indicate the possible use of LaBr3 scintillation detectors when high count rate capability may outweigh the lower energy resolution.« less

  5. Delayed gamma-ray spectroscopy with lanthanum bromide detector for non-destructive assay of nuclear material

    DOE PAGES

    Favalli, Andrea; Iliev, Metodi; Ianakiev, Kiril; ...

    2017-10-09

    High-energy delayed γ-ray spectroscopy is a potential technique for directly assaying spent fuel assemblies and achieving the safeguards goal of quantifying nuclear material inventories for spent fuel handling, interim storage, reprocessing facilities, repository sites, and final disposal. Requirements for the γ-ray detection system, up to ~6 MeV, can be summarized as follows: high efficiency at high γ-ray energies, high energy resolution, good linearity between γ-ray energy and output signal amplitude, ability to operate at very high count rates, and ease of use in industrial environments such as nuclear facilities. High Purity Germanium Detectors (HPGe) are the state of the artmore » and provide excellent energy resolution but are limited in their count rate capability. Lanthanum Bromide (LaBr 3) scintillation detectors offer significantly higher count rate capabilities at lower energy resolution. Thus, LaBr 3 detectors may be an effective alternative for nuclear spent-fuel applications, where count-rate capability is a requirement. This paper documents the measured performance of a 2” (length) × 2” (diameter) of LaBr3 scintillation detector system, coupled to a negatively biased PMT and a tapered active high voltage divider, with count-rates up to ~3 Mcps. An experimental methodology was developed that uses the average current from the PMT’s anode and a dual source method to characterize the detector system at specific very high count rate values. Delayed γ-ray spectra were acquired with the LaBr 3 detector system at the Idaho Accelerator Center, Idaho State University, where samples of ~3g of 235U were irradiated with moderated neutrons from a photo-neutron source. Results of the spectroscopy characterization and analysis of the delayed γ-ray spectra acquired indicate the possible use of LaBr3 scintillation detectors when high count rate capability may outweigh the lower energy resolution.« less

  6. Delayed gamma-ray spectroscopy with lanthanum bromide detector for non-destructive assay of nuclear material

    NASA Astrophysics Data System (ADS)

    Favalli, Andrea; Iliev, Metodi; Ianakiev, Kiril; Hunt, Alan W.; Ludewigt, Bernhard

    2018-01-01

    High-energy delayed γ-ray spectroscopy is a potential technique for directly assaying spent fuel assemblies and achieving the safeguards goal of quantifying nuclear material inventories for spent fuel handling, interim storage, reprocessing facilities, repository sites, and final disposal. Requirements for the γ-ray detection system, up to ∼6 MeV, can be summarized as follows: high efficiency at high γ-ray energies, high energy resolution, good linearity between γ-ray energy and output signal amplitude, ability to operate at very high count rates, and ease of use in industrial environments such as nuclear facilities. High Purity Germanium Detectors (HPGe) are the state of the art and provide excellent energy resolution but are limited in their count rate capability. Lanthanum Bromide (LaBr3) scintillation detectors offer significantly higher count rate capabilities at lower energy resolution. Thus, LaBr3 detectors may be an effective alternative for nuclear spent-fuel applications, where count-rate capability is a requirement. This paper documents the measured performance of a 2" (length) × 2" (diameter) of LaBr3 scintillation detector system, coupled to a negatively biased PMT and a tapered active high voltage divider, with count-rates up to ∼3 Mcps. An experimental methodology was developed that uses the average current from the PMT's anode and a dual source method to characterize the detector system at specific very high count rate values. Delayed γ-ray spectra were acquired with the LaBr3 detector system at the Idaho Accelerator Center, Idaho State University, where samples of ∼3g of 235U were irradiated with moderated neutrons from a photo-neutron source. Results of the spectroscopy characterization and analysis of the delayed γ-ray spectra acquired indicate the possible use of LaBr3 scintillation detectors when high count rate capability may outweigh the lower energy resolution.

  7. Impurities in Tc-99m radiopharmaceutical solution obtained from Mo-100 in cyclotron.

    PubMed

    Tymiński, Zbigniew; Saganowski, Paweł; Kołakowska, Ewa; Listkowska, Anna; Ziemek, Tomasz; Cacko, Daniel; Dziel, Tomasz

    2018-04-01

    The gamma emitting impurities in 99m Tc solution obtained from enriched molybdenum 100 Mo metallic target after its irradiation in a cyclotron were measured using a high-purity germanium (HPGe) detector. The radioactivity range of tested samples of 99m Tc was rather low, in the range from 0.34 to 2.39 MBq, thus creating a challenge to investigate the standard measurement HPGe system for impurity detection and quantification. In the process of 99m Tc separation from irradiated target the AnaLig® Tc-02 resin, Dionex H + and Alumina A columns were used. Fractions of eluates from various steps of separation process were taken and measured for radionuclidic purity. The overall measurement sensitivity of gamma emitters in terms of minimum detectable activity (MDA) was found at the level of 14-70Bq with emission lines in range of 36 - 1836keV resulting in impurity content range of 6.7 × 10 -4 to 3.4 × 10 -3 % for 93 Tc, 93m Tc, 94 Tc, 94m Tc, 95 Tc, 95m Tc, 96 Tc 96 Nb, 97 Nb, 99 Mo contaminants and 9.4 × 10 -3 % for 97m Tc. The usefulness of the chosen measurement conditions and the method applied to testing the potential contaminators was proved by reaching satisfactory results of MDAs less than the criteria of impurity concentration of all nuclides specified in the European Pharmacopoeia. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Performance of a miniature mechanically cooled HPGe gamma-spectrometer for space applications

    NASA Astrophysics Data System (ADS)

    Kondratjev, V.; Pchelintsev, A.; Jakovlevs, O.; Sokolov, A.; Gostilo, V.; Owens, A.

    2018-01-01

    We report on the development of a miniaturized HPGe gamma-spectrometer for space applications. The instrument is designed around a 158 cm3 intrinsically pure Ge crystal in the closed-end coaxial configuration, cooled by a Thales RM3 miniature Stirling cycle electric cooler. To compensate the noise induced by the mechanical cooler the digital procession of the spectrometric signals with low frequency reject filter (LFR) is applied. The complete spectrometer assembly has a mass of 3.1 kg and consumes less than 10 W under working operation. The spectrometer was tested under a number of operating conditions in a specially designed chamber, which simulates the space environment. With the mechanical cooler switched off, FWHM energy resolutions of 1.5 keV and 2.2 keV were obtained at 122 keV and 1333 keV, respectively, at the nominal operating temperature of 90 K. When the cooler was switched on the energy resolutions degraded to 2.5 keV and 4 keV respectively. However, with the LFR filter switched in, the resolutions improved significantly to 1.8 keV and 2.4 keV.

  9. The Majorana Demonstrator search for neutrinoless double beta decay

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cuesta, C.; Buuck, M.; Detwiler, Jason A.

    2016-12-12

    The MAJORANA Collaboration is constructing the MAJORANA DEMONSTRATOR, an ultra-low background, modular, HPGe detector array with a mass of 44.8-kg (29.7 kg enriched 88% in 76Ge) to search for neutrinoless double beta decay in 76Ge. The next generation of tonnescale Ge-based neutrinoless double beta decay searches will probe the neutrino mass scale in the inverted-hierarchy region. The MAJORANA DEMONSTRATOR is envisioned to demonstrate a path forward to achieve a background rate at or below 1 count/tonne/year in the 4 keV region of interest around the Q-value of 2039 keV. The MAJORANA DEMONSTRATOR follows a modular implementation to be easily scalablemore » to the next generation experiment. First data taken with the DEMONSTRATOR are introduced here.« less

  10. Experimental measurement of the 12C+16O fusion cross sections at astrophysical energies

    NASA Astrophysics Data System (ADS)

    Fang, X.; Tan, W. P.; Beard, M.; deBoer, R. J.; Gilardy, G.; Jung, H.; Liu, Q.; Lyons, S.; Robertson, D.; Setoodehnia, K.; Seymour, C.; Stech, E.; Vande Kolk, B.; Wiescher, M.; de Souza, R.; Hudan, S.; Singh, V.; Tang, X. D.; Uberseder, E.

    2018-05-01

    The total cross sections of the 12C+16O fusion have been experimentally determined at low energies to investigate the role of this reaction during late stellar evolution burning phases. A high-intensity oxygen beam was produced by the 5MV pelletron accelerator at the University of Notre Dame impinging on a thick ultra-pure graphite target. Protons and γ-rays were measured simultaneously in the center-of-mass energy range from 3.64 to 5.01 MeV, using strip silicon and HPGe detectors. Statistical model calculations were employed to interpret the experimental results. A new broad resonance-like structure is observed for the 12C+16O reaction, and a decreasing trend of its S-factor towards low energies is found.

  11. Excitations of one-valence-proton, one-valence-neutron nucleus {sup 210}Bi from cold-neutron capture

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cieplicka-Oryńczak, N.; Institute of Nuclear Physics, Polish Academy of Sciences, PL-31342 Kraków; Fornal, B.

    2015-10-15

    The low-spin structure of one-proton, one-neutron {sup 210}Bi nucleus was investigated in cold-neutron capture reaction on {sup 209}Bi. The γ-coincidence measurements were performed with use of EXILL array consisted of 16 HPGe detectors. The experimental results were compared to shell-model calculations involving valence particles excitations. The {sup 210}Bi nucleus offers the potential to test the effective proton-neutron interactions because most of the states should arise from the proton-neutron excitations. Additionally, it was discovered that a few states should come from the couplings of valence particles to the 3{sup −} octupole vibration in {sup 208}Pb which provides also the possibility ofmore » testing the calculations involving the core excitations.« less

  12. The ground support equipment for the LAUE project

    NASA Astrophysics Data System (ADS)

    Caroli, E.; Auricchio, N.; Basili, A.; Carassiti, V.; Cassese, F.; Del Sordo, S.; Frontera, F.; Pecora, M.; Recanatesi, L.; Schiavone, F.; Silvestri, S.; Squerzanti, S.; Stephen, J. B.; Virgilli, E.

    2013-09-01

    The development of wide band Laue lens imaging technology is challenging, but has important potential applications in hard X- and γ-ray space instrumentation for the coming decades. The Italian Space Agency has funded a project dedicated to the development of a reliable technology to assemble a wide band Laue lens for use in space. The ground support equipment (GSE) for this project was fundamental to its eventual success... The GSE was implemented in a hard X-ray beam line built at the University of Ferrara and had the main purpose of controlling the assembly of crystals onto the Laue lens petal and to verify its final performance. The GSE incorporates the management and control of all the movements of the beam line mechanical subsystems and of the precision positioner (based on a Hexapod tool) of crystals on the petal, as well as the acquisition, storing and analysis of data obtained from the focal plane detectors (an HPGe spectrometer and an X-ray flat panel imager). The GSE is based on two PC's connected through a local network: one, placed inside the beam line, to which all the movement subsystems and the detector I/O interface and on which all the management and acquisition S/W runs, the other in the control room allows the remote control and implements the offline analysis S/W of the data obtained from the detectors. Herein we report on the GSE structure with its interface with the beam line mechanical system, with the fine crystal positioner and with the focal plane detector. Furthermore we describe the SW developed for the handling of the mechanical movement subsystems and for the analysis of the detector data with the procedure adopted for the correct orientation of the crystals before their bonding on the lens petal support.

  13. The use of γ-rays analysis by HPGe detector to assess the gross alpha and beta activities in waters.

    PubMed

    Casagrande, M F S; Bonotto, D M

    2018-07-01

    This paper describes an alternative method for evaluating gross alpha and beta radioactivity in waters by using γ-rays analysis performed with hyper-pure germanium detector (HPGe). Several gamma emissions related to α and β - decays were used to provide the activity concentration data due to natural radionuclides commonly present in waters like 40 K and those belonging to the 238 U and 232 Th decay series. The most suitable gamma emissions related to β - decays were 214 Bi (1120.29 keV, 238 U series) and 208 Tl (583.19 keV, 232 Th series) as the equation in activity concentration yielded values compatible to those generated by the formula taking into account the detection efficiency. The absence of isolated and intense γ-rays peaks associated to α decays limited the choice to 226 Ra (186.21 keV, 238 U series) and 224 Ra (240.99 keV, 232 Th series). In these cases, it was adopted appropriate correction factors involving the absolute intensities and specific activities for avoiding the interferences of other γ-rays energies. The critical level of detection across the 186-1461 keV energy region corresponded to 0.010, 0.023, 0.038, 0.086, and 0.042 Bq/L, respectively, for 226 Ra, 224 Ra, 208 Tl, 214 Bi and 40 K. It is much lower than the WHO guideline reference value for gross alpha (0.5 Bq/L) and beta (1.0 Bq/L) in waters. The method applicability was checked by the analysis of groundwater samples from different aquifer systems occurring in the Brazilian states of São Paulo, Minas Gerais and Mato Grosso do Sul. The waters exhibit very different chemical composition and the samples with the highest radioactivity levels were those associated with lithotypes possessing enhanced uranium and thorium levels. The technique allowed directly discard the 40 K contribution to the gross beta activity as potassium is an essential element for humans. Copyright © 2018 Elsevier Ltd. All rights reserved.

  14. Study of the counting efficiency of a WBC setup by using a computational 3D human body library in sitting position based on polygonal mesh surfaces.

    PubMed

    Fonseca, T C Ferreira; Bogaerts, R; Lebacq, A L; Mihailescu, C L; Vanhavere, F

    2014-04-01

    A realistic computational 3D human body library, called MaMP and FeMP (Male and Female Mesh Phantoms), based on polygonal mesh surface geometry, has been created to be used for numerical calibration of the whole body counter (WBC) system of the nuclear power plant (NPP) in Doel, Belgium. The main objective was to create flexible computational models varying in gender, body height, and mass for studying the morphology-induced variation of the detector counting efficiency (CE) and reducing the measurement uncertainties. First, the counting room and an HPGe detector were modeled using MCNPX (Monte Carlo radiation transport code). The validation of the model was carried out for different sample-detector geometries with point sources and a physical phantom. Second, CE values were calculated for a total of 36 different mesh phantoms in a seated position using the validated Monte Carlo model. This paper reports on the validation process of the in vivo whole body system and the CE calculated for different body heights and weights. The results reveal that the CE is strongly dependent on the individual body shape, size, and gender and may vary by a factor of 1.5 to 3 depending on the morphology aspects of the individual to be measured.

  15. Screening and Spectral Summing of LANL Empty Waste Drums - 13226

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gruetzmacher, Kathleen M.; Bustos, Roland M.; Ferran, Scott G.

    2013-07-01

    Empty 55-gallon drums that formerly held transuranic (TRU) waste (often over-packed in 85- gallon drums) are generated at LANL and require radiological characterization for disposition. These drums are typically measured and analyzed individually using high purity germanium (HPGe) gamma detectors. This approach can be resource and time intensive. For a project requiring several hundred drums to be characterized in a short time frame, an alternative approach was developed. The approach utilizes a combination of field screening and spectral summing that was required to be technically defensible and meet the Nevada Nuclear Security Site (NNSS) Waste Acceptance Criteria (WAC). In themore » screening phase of the operation, the drums were counted for 300 seconds (compared to 600 seconds for the typical approach) and checked against Low Level (LL)/TRU thresholds established for each drum configuration and detector. Multiple TRU nuclides and multiple gamma rays for each nuclide were evaluated using an automated spreadsheet utility that can process data from up to 42 drums at a time. Screening results were reviewed by an expert analyst to confirm the field LL/TRU determination. The spectral summing analysis technique combines spectral data (channel-by-channel) associated with a group of individual waste containers producing a composite spectrum. The grouped drums must meet specific similarity criteria. Another automated spreadsheet utility was used to spectral sum data from an unlimited number of similar drums grouped together. The composite spectrum represents a virtual combined drum for the group of drums and was analyzed using the SNAP{sup TM}/Radioassay Data Sheet (RDS)/Batch Data Report (BDR) method. The activity results for a composite virtual drum were divided equally amongst the individual drums to generate characterization results for each individual drum in the group. An initial batch of approximately 500 drums were measured and analyzed in less than 2 months in 2011. A second batch of approximately 500 more drums were measured and analyzed during the following 2 1/2 months. Four different HPGe detectors were employed for the operation. The screening and spectral summing approach can reduce the overall measurement and analysis time required. However, developing the technical details and automation spreadsheets requires a significant amount of expert time prior to beginning field operations and must be considered in the overall project schedule. This approach has continued to be used for characterizing several hundred more empty drums in 2012 and is planned to continue in 2013. (authors)« less

  16. Neutron Capture Reaction on 112Cd to Study of the s-process Origin of 115Sn

    NASA Astrophysics Data System (ADS)

    Hayakawa, Takehito; Toh, Yosuke; Shizuma, Toshiyuki; Kimura, Atsushi; Nakamura, Shoji; Harada, Hideo; Iwamoto, Nobuyuki; Kajino, Toshitaka; Chiba, Satoshi

    The astrophysical origin of 115Sn has remained still an open question. An isomer with a half-life of 14.1 y in 113Cd is a branching point from which a nucleosynthesis flow reaches to a rare isotope 115Sn. The s-process abundance of 115Sn depends on the ratio of the 112Cd(n, γ)113Cdm reaction cross section to the 112Cd(n, γ)113Cdgs reaction cross section. However, the isomer production ratio following the neutron capture reaction has not been measured in an energy region higher than the thermal energy. We have measured γ-ray intensity ratios following neutron capture reactions on 112Cd using the HPGe detectors in conjunction with a time-of-flight method at ANNRI in J-PARC.

  17. Natural radioactivity investigation in Dam sediments of northeast Algeria using gamma spectroscopy

    NASA Astrophysics Data System (ADS)

    Benrachi, Fatima; Bouhila, Ghania; Saadi, Asma; Ramdhane, Mourad

    2017-09-01

    Current research paper intends to estimate the natural radioactivity levels in sediments samples collected from Beni Haroun Dam in the northeast Algeria, using high resolution HPGe detector. The mean activity concentrations values measured for the radionuclides 232Th, 226Ra and 40K are 18.9 ± 1.9, 37.3 ± 2.7 and 149.9 ± 5.5 Bq/kg, respectively. The 137Cs anthropogenic radionuclide has been observed with maximum activity concentration value of 0.8 ± 0.4 Bq/kg, which is considered an insignificant amount. In order to assess the radiological threat of gamma radiations emitted by these radionuclides on the health of the population, absorbed dose rate, annual effective dose equivalent and radiation hazard indices were had been calculated. The obtained values are compared with the world wide average ones.

  18. Investigation of the vibration and EMC characteristics of miniature Stirling electric coolers for space applications

    NASA Astrophysics Data System (ADS)

    Kondratjev, V.; Gostilo, V.; Owens, anb A.

    2017-08-01

    We present the results of an investigation into the detrimental effects that electromechanical coolers can have on the spectral performance of compact, large volume HPGe spectrometers for space applications. Both mechanical vibration and electromagnetic pickup effects were considered, as well as a comparative assessment between three miniature Stirling cycle coolers—two Ricor model K508 coolers and one Thales model RM3 cooler. In spite of the limited number of coolers tested, the following conclusions can be made. There are significant differences in the vibration characteristics not only between the various types of cooler but also between coolers of the same type. It was also found that compared to the noise induced by mechanical vibrations, electromagnetic interference emanating from the embedded controllers does not significantly impact the energy resolution of detectors.

  19. Prompt-delayed $$\\gamma$$-ray spectroscopy with AGATA, EXOGAM and VAMOS++

    DOE PAGES

    Kim, Y. H.; Lemasson, A.; Rejmund, M.; ...

    2017-08-10

    Here, a new experimental setup to measure prompt-delayed γ-ray coincidences from isotopically identified fission fragments, over a wide time range of 100ns-200μ s, is presented. The fission fragments were isotopically identified, on an event-by-event basis, using the VAMOS++ large acceptance spectrometer. The prompt γ rays emitted at the target position and corresponding delayed γ rays emitted at the focal plane of the spectrometer were detected using, respectively, thirty two crystals of the AGATA γ-ray tracking array and seven EXOGAM HPGe Clover detectors. Finally, fission fragments produced in fusion and transfer-induced fission reactions, using a 238U beam at an energy ofmore » 6.2 MeV/u impinging on a 9Be target, were used to characterize and qualify the performance of the detection system.« less

  20. Characterisation of imperial college reactor centre legacy waste using gamma-ray spectrometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shuhaimi, Alif Imran Mohd

    Waste characterisation is a principal component in waste management strategy. The characterisation includes identification of chemical, physical and radiochemical parameters of radioactive waste. Failure to determine specific waste properties may result in sentencing waste packages which are not compliant with the regulation of long term storage or disposal. This project involved measurement of intensity and energy of gamma photons which may be emitted by radioactive waste generated during decommissioning of Imperial College Reactor Centre (ICRC). The measurement will use High Purity Germanium (HPGe) as Gamma-ray detector and ISOTOPIC-32 V4.1 as analyser. In order to ensure the measurements provide reliable results,more » two quality control (QC) measurements using difference matrices have been conducted. The results from QC measurements were used to determine the accuracy of the ISOTOPIC software.« less

  1. Neutron capture cross-section studies of Tellurium isotopes for neutrinoless double beta decay applications

    NASA Astrophysics Data System (ADS)

    Bhike, Megha; Tornow, Werner

    2014-09-01

    The CUORE detector at Gran Sasso, aimed at searching for neutrinoless double-beta decay of 130Te, employs an array of TeO2 bolometer modules. To understand and identify the contribution of muon and (α,n) induced neutrons to the CUORE background, fast neutron cature cross-section data of the tellurium isotopes 126Te, 128Te and 130Te have been measured with the activation method at eight different energies in the neutron energy range 0.5-7.5 MeV. Plastic pill boxes of diameter 1.6 cm and width 1 cm containing Te were irradiated with mono-energetic neutrons produced via the 3H(p,n)3He and 2H(d,n)3He reactions. The cross-sections were determined relative to the 197Au(n, γ)198Au and 115In(n,n')115m In standard cross sections. The activities of the products were measured using 60% lead-shielded HPGe detectors at TUNL's low background counting facility. The present results are compared with the evaluated data from TENDL-2012, ENDF/B-VII.1, JEFF-3.2 and JENDL-4.0, as well as with literature data.

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ovard R. Perry; David L. Georgeson

    This report describes the April 2011 calibration of the Accuscan II HpGe In Vivo system for high energy lung counting. The source used for the calibration was a NIST traceable lung set manufactured at the University of Cincinnati UCLL43AMEU & UCSL43AMEU containing Am-241 and Eu-152 with energies from 26 keV to 1408 keV. The lung set was used in conjunction with a Realistic Torso phantom. The phantom was placed on the RMC II counting table (with pins removed) between the v-ridges on the backwall of the Accuscan II counter. The top of the detector housing was positioned perpendicular to themore » junction of the phantom clavicle with the sternum. This position places the approximate center line of the detector housing with the center of the lungs. The energy and efficiency calibrations were performed using a Realistic Torso phantom (Appendix I) and the University of Cincinnati lung set. This report includes an overview introduction and records for the energy/FWHM and efficiency calibration including performance verification and validation counting. The Accuscan II system was successfully calibrated for high energy lung counting and verified in accordance with ANSI/HPS N13.30-1996 criteria.« less

  3. Low energy positron beam system for the investigation of 2D and porous materials

    NASA Astrophysics Data System (ADS)

    Chrysler, M. D.; Chirayath, V. A.; Mcdonald, A. D.; Gladen, R. W.; Fairchild, A. J.; Koymen, A. R.; Weiss, A. H.

    2017-01-01

    An advanced variable energy positron beam (~2 eV to 20 keV) has been designed, tested and utilized for coincidence Doppler broadening (CDB) measurements at the University of Texas at Arlington (UTA). A high efficiency solidified rare gas (Neon) moderator was used for the generation of a slow positron beam. The gamma rays produced as a result of the annihilation of positrons with the sample electrons are measured using a high purity Germanium (HPGe) detector in coincidence with a NaI(Tl) detector. Modifications to the system, currently underway, permits simultaneous measurements utilizing Positron annihilation induced Auger Electron Spectroscopy (PAES) and CDB. The tendency of positrons to become trapped in an image potential well at the surface will allow the new system to be used in measurements of the chemical structure of surfaces, internal or external and interfaces. The system will utilize a time of flight (TOF) technique for electron energy measurements. A 3m flight path from the sample to a micro-channel plate (MCP) in the new system will give it superior energy resolution at higher electron energies as compared to previous TOF systems utilizing shorter flight paths.

  4. A system to measure isomeric state half-lives in the 10 ns to 10 μs range

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Toufen, D. L., E-mail: dennis@if.usp.br; Federal Institute of Education, Science and Technology of São Paulo - IFSP, 07115-000 Guarulhos, São Paulo; Allegro, P. R. P.

    2014-07-15

    The Isomeric State Measurement System (SISMEI) was developed to search for isomeric nuclear states produced by fusion-evaporation reactions. The SISMEI consists of 10 plastic phoswich telescopes, two lead shields, one NaI(Tl) scintillation detector, two Compton suppressed HPGe γ-ray detectors, and a cone with a recoil product catcher. The new system was tested at the 8 UD Pelletron tandem accelerator of the University of São Paulo with the measurement of two known isomeric states: {sup 54}Fe, 10{sup +} state (E = 6527.1 (11) keV, T{sub 1/2} = 364(7) ns) and the 5/2{sup +} state of {sup 19}F (E = 197.143 (4)more » keV, T{sub 1/2} = 89.3 (10) ns). The results indicate that the system is capable of identifying delayed transitions, of measuring isomeric state lifetimes, and of identifying the feeding transitions of the isomeric state through the delayed γ-γ coincidence method. The measured half-life for the 10{sup +} state was T{sub 1/2} = 365(14) ns and for the 5/2{sup +} state, 100(36) ns.« less

  5. The boundary of the N=90 shape phase transition: 148Ce

    NASA Astrophysics Data System (ADS)

    Koseoglou, P.; Werner, V.; Pietralla, N.; Ilieva, S.; Thürauf, M.; Bernards, C.; Blanc, A.; Bruce, A. M.; Cakirli, R. B.; Cooper, N.; Fraile, L. M.; de France, G.; Jentschel, M.; Jolie, J.; Koester, U.; Korten, W.; Kröll, T.; Lalkovski, S.; Mach, H.; Mărginean, N.; Mutti, P.; Patel, Z.; Paziy, V.; Podolyák, Z.; Regan, P. H.; Régis, J.-M.; Roberts, O. J.; Saed-Samii, N.; Simpson, G. S.; Soldner, T.; Ur, C. A.; Urban, W.; Wilmsen, D.; Wilson, E.

    2018-05-01

    The even-even N=90 isotones with Z=60-66 are known to undergo a first order phase transition. Such a phase transition in atomic nuclei is characterized by a sudden change of the shape of the nucleus due to changes in the location of the potential minimum. In these proceedings we report a measurement of the B4/2 ratio of 148Ce, which will probe the location of the low-Z boundary of the N=90 phase transitional region. The measured B4/2 value is compared to the prediction from the X(5) symmetry within the interacting boson model at the critical point between the geometrical limits of vibrators and rigid/axial rotors. The EXILL&FATIMA campaign took place at the high-flux reactor of the Institut Laue Langevin, Grenoble, were 235U and 241Pu fission fragments were measured by a hybrid spectrometer consisting of high-resolution HPGe and fast LaBr3(Ce)-scintillator detectors. The fast LaBr3(Ce) detectors in combination with the generalized centroid difference method allowed lifetime measurements in the picosecond region. Furthermore, this kind of analysis can serve as preparation for the FATIMA experiments at FAIR.

  6. Pulse Shape Discrimination in the MAJORANA DEMONSTRATOR

    NASA Astrophysics Data System (ADS)

    Haufe, Christopher; Majorana Collaboration

    2017-09-01

    The MAJORANA DEMONSTRATOR is an experiment constructed to search for neutrinoless double-beta decays in germanium-76 and to demonstrate the feasibility to deploy a large-scale experiment in a phased and modular fashion. It consists of two modular arrays of natural and 76Ge-enriched germanium p-type point contact detectors totaling 44.1 kg, located at the 4850' level of the Sanford Underground Research Facility in Lead, South Dakota, USA. A large effort is underway to analyze the data currently being taken by the DEMONSTRATOR. Key components of this effort are analysis tools that allow for pulse shape discrimination-techniques that significantly reduce background levels in the neutrinoless double-beta decay region of interest. These tools are able to identify and reject multi-site events from Compton scattering as well as events from alpha particle interactions. This work serves as an overview for these analysis tools and highlights the unique advantages that the HPGe p-type point contact detector provides to pulse shape discrimination. This material is supported by the U.S. Department of Energy, Office of Science, Office of Nuclear Physics, the Particle Astrophysics and Nuclear Physics Programs of the National Science Foundation, and the Sanford Underground Research Facility.

  7. Radon emanation based material measurement and selection for the SuperNEMO double beta experiment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cerna, Cédric, E-mail: cerna@cenbg.in2p3.fr; Soulé, Benjamin; Perrot, Frédéric

    The SuperNEMO Demonstrator experiment aims to study the neutrinoless double beta decay of 7 kg of {sup 82}Se in order to reach a limit on the light Majorana neutrino mass mechanism T{sub 1/2} (ββ0ν) > 6.5 10{sup 24} years (90%CL) equivalent to a mass sensitivity mβ{sub β} < 0.20 - 0.40 eV (90%CL) in two years of data taking. The detector construction started in 2014 and its installation in the Laboratoire Souterrain de Modane (LSM) is expected during the course of 2015. The remaining level of {sup 226}Ra ({sup 238}U chain) in the detector components can lead to the emanationmore » of {sup 222}Rn gas. This isotope should be controlled and reduced down to the level of a 150 µBq/m{sup 3} in the tracker chamber of the detector to achieve the physics goals. Besides the HPGe selection of the detector materials for their radiopurity, the most critical materials have been tested and selected in a dedicated setup facility able to measure their {sup 222}Rn emanation level. The operating principle relies on a large emanation tank (0.7m{sup 3}) that allows measuring large material surfaces or large number of construction pieces. The emanation tank is coupled to an electrostatic detector equipped with a silicon diode to perform the alpha spectroscopy of the gas it contains and extract the {sup 222}Rn daughters. The transfer efficiency and the detector efficiency have been carefully calibrated through different methods. The intrinsic background of the system allows one to measure 222Rn activities down to 3 mBq, leading to a typical emanation sensitivity of 20 µBq/m{sup 2}/day for a 30 m{sup 2} surface sample. Several construction materials have been measured and selected, such as nylon and aluminized Mylar films, photomultipliers and tracking of the SuperNEMO Demonstrator.« less

  8. Simulation and Digitization of a Gas Electron Multiplier Detector Using Geant4 and an Object-Oriented Digitization Program

    NASA Astrophysics Data System (ADS)

    McMullen, Timothy; Liyanage, Nilanga; Xiong, Weizhi; Zhao, Zhiwen

    2017-01-01

    Our research has focused on simulating the response of a Gas Electron Multiplier (GEM) detector using computational methods. GEM detectors provide a cost effective solution for radiation detection in high rate environments. A detailed simulation of GEM detector response to radiation is essential for the successful adaption of these detectors to different applications. Using Geant4 Monte Carlo (GEMC), a wrapper around Geant4 which has been successfully used to simulate the Solenoidal Large Intensity Device (SoLID) at Jefferson Lab, we are developing a simulation of a GEM chamber similar to the detectors currently used in our lab. We are also refining an object-oriented digitization program, which translates energy deposition information from GEMC into electronic readout which resembles the readout from our physical detectors. We have run the simulation with beta particles produced by the simulated decay of a 90Sr source, as well as with a simulated bremsstrahlung spectrum. Comparing the simulation data with real GEM data taken under similar conditions is used to refine the simulation parameters. Comparisons between results from the simulations and results from detector tests will be presented.

  9. Decay spectroscopy for nuclear astrophysics: β- and β-delayed proton decay

    NASA Astrophysics Data System (ADS)

    Trache, L.; Banu, A.; Hardy, J. C.; Iacob, V. E.; McCleskey, M.; Roeder, B. T.; Simmons, E.; Spiridon, A.; Tribble, R. E.; Saastamoinen, A.; Jokinen, A.; Äysto, J.; Davinson, T.; Lotay, G.; Woods, P. J.; Pollacco, E.

    2012-02-01

    In several radiative proton capture reactions important in novae and XRBs, the resonant parts play the capital role. We use decay spectroscopy techniques to find these resonances and study their properties. We have developed techniques to measure beta- and beta-delayed proton decay of sd-shell, proton-rich nuclei produced and separated with the MARS recoil spectrometer of Texas A&M University. The short-lived radioactive species are produced in-flight, separated, then slowed down (from about 40 MeV/u) and implanted in the middle of very thin Si detectors. This allows us to measure protons with energies as low as 200 keV from nuclei with lifetimes of 100 ms or less. At the same time we measure gamma-rays up to 8 MeV with high resolution HPGe detectors. We have studied the decay of 23Al, 27P, 31Cl, all important for understanding explosive H-burning in novae. The technique has shown a remarkable selectivity to beta-delayed charged-particle emission and works even at radioactive beam rates of a few pps. The states populated are resonances for the radiative proton capture reactions 22Na(p,γ)23Mg (crucial for the depletion of 22Na in novae), 26mAl(p,γ)27Si and 30P(p,γ)31S (bottleneck in novae and XRB burning), respectively. Lastly, results with a new detector that allowed us to measure down to about 80 keV proton energy are announced.

  10. Photon strength and the low-energy enhancement

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wiedeking, M.; Bernstein, L. A.; Bleuel, D. L.

    2014-08-14

    Several measurements in medium mass nuclei have reported a low-energy enhancement in the photon strength function. Although, much effort has been invested in unraveling the mysteries of this effect, its physical origin is still not conclusively understood. Here, a completely model-independent experimental approach to investigate the existence of this enhancement is presented. The experiment was designed to study statistical feeding from the quasi-continuum (below the neutron separation energy) to individual low-lying discrete levels in {sup 95}Mo produced in the (d, p) reaction. A key aspect to successfully study gamma decay from the region of high-level density is the detection andmore » extraction of correlated particle-gamma-gamma events which was accomplished using an array of Clover HPGe detectors and large area annular silicon detectors. The entrance channel excitation energy into the residual nucleus produced in the reaction was inferred from the detected proton energies in the silicon detectors. Gating on gamma-transitions originating from low-lying discrete levels specifies the state fed by statistical gamma-rays. Any particle-gamma-gamma event in combination with specific energy sum requirements ensures a clean and unambiguous determination of the initial and final state of the observed gamma rays. With these requirements the statistical feeding to individual discrete levels is extracted on an event-by-event basis. The results are presented and compared to {sup 95}Mo photon strength function data measured at the University of Oslo.« less

  11. X-ray pinhole camera setups used in the Atomki ECR Laboratory for plasma diagnostics.

    PubMed

    Rácz, R; Biri, S; Pálinkás, J; Mascali, D; Castro, G; Caliri, C; Romano, F P; Gammino, S

    2016-02-01

    Imaging of the electron cyclotron resonance (ECR) plasmas by using CCD camera in combination with a pinhole is a non-destructive diagnostics method to record the strongly inhomogeneous spatial density distribution of the X-ray emitted by the plasma and by the chamber walls. This method can provide information on the location of the collisions between warm electrons and multiple charged ions/atoms, opening the possibility to investigate the direct effect of the ion source tuning parameters to the plasma structure. The first successful experiment with a pinhole X-ray camera was carried out in the Atomki ECR Laboratory more than 10 years ago. The goal of that experiment was to make the first ECR X-ray photos and to carry out simple studies on the effect of some setting parameters (magnetic field, extraction, disc voltage, gas mixing, etc.). Recently, intensive efforts were taken to investigate now the effect of different RF resonant modes to the plasma structure. Comparing to the 2002 experiment, this campaign used wider instrumental stock: CCD camera with a lead pinhole was placed at the injection side allowing X-ray imaging and beam extraction simultaneously. Additionally, Silicon Drift Detector (SDD) and High Purity Germanium (HPGe) detectors were installed to characterize the volumetric X-ray emission rate caused by the warm and hot electron domains. In this paper, detailed comparison study on the two X-ray camera and detector setups and also on the technical and scientific goals of the experiments is presented.

  12. Measurements of the 169Tm(n,2n)168Tm cross section between 9.0 and 17.5 MeV

    NASA Astrophysics Data System (ADS)

    Soter, J.; Bhike, Megha; Krishichayan, Fnu; Finch, S. W.; Tornow, W.

    2016-09-01

    Measurements of the 169Tm(n,2n)168Tm cross section have been performed in 0.5 MeV intervals for neutron energies ranging from 9.0 MeV to 17.5 MeV in order to resolve discrepancies in the current literature data. The neutron activation technique was used with 90Zr and 197Au as monitor foils. After irradiation, de-excitation gamma rays were recorded off-line with High-Purity Germanium (HPGE) detectors in TUNL's Low-Background Counting Facility. In addition, data for the 169Tm(n,3n)167Tm reaction have also been obtained from 15.5 MeV to 17.5 MeV. The results of these measurements provide the basis for investigating properties of the interial confinement fusion plasma in deuterium-tritium (DT) capsules at the National Ignition Facility located at Lawrence Livermore National Laboratory.

  13. High-Precision Half-life Measurements for the Superallowed β+ Emitter 14O

    NASA Astrophysics Data System (ADS)

    Laffoley, A. T.; Svensson, C. E.; Andreoiu, C.; Austin, R. A. E.; Ball, G. C.; Blank, B.; Bouzomita, H.; Cross, D. S.; Diaz Varela, A.; Dunlop, R.; Finlay, P.; Garnsworthy, A. B.; Garrett, P. E.; Giovinazzo, J.; Grinyer, G. F.; Hackman, G.; Hadinia, B.; Jamieson, D. S.; Ketelhut, S.; Leach, K. G.; Leslie, J. R.; Tardiff, E. R.; Thomas, J. C.; Unsworth, C.

    2014-03-01

    The half-life of 14O, a superallowed Fermi β+ emitter, has been determined via simultaneous γ and β counting experiments at TRIUMF's Isotope Separator and Accelerator facility. Following the implantation of 14O samples at the center of the 8π spectrometer, a γ counting measurement was performed by detecting the 2313 keV γ-rays emitted from the first excited state of the daughter 14N using 20 high-purity germanium (HPGe) detectors. A simultaneous β counting experiment was performed using a fast plastic scintillator positioned directly behind the implantation site. The results, T½(γ) = 70:632 ± 0:094 s and T½(β) = 70:610 ± 0:030 s, are consistent with one another and, together with eight previous measurements, establish a new average for the 14O half-life of T½ = 70:619 ± 0:011 s with a reduced χ2 of 0.99.

  14. Automation system for measurement of gamma-ray spectra of induced activity for multi-element high volume neutron activation analysis at the reactor IBR-2 of Frank Laboratory of Neutron Physics at the joint institute for nuclear research

    NASA Astrophysics Data System (ADS)

    Pavlov, S. S.; Dmitriev, A. Yu.; Chepurchenko, I. A.; Frontasyeva, M. V.

    2014-11-01

    The automation system for measurement of induced activity of gamma-ray spectra for multi-element high volume neutron activation analysis (NAA) was designed, developed and implemented at the reactor IBR-2 at the Frank Laboratory of Neutron Physics. The system consists of three devices of automatic sample changers for three Canberra HPGe detector-based gamma spectrometry systems. Each sample changer consists of two-axis of linear positioning module M202A by DriveSet company and disk with 45 slots for containers with samples. Control of automatic sample changer is performed by the Xemo S360U controller by Systec company. Positioning accuracy can reach 0.1 mm. Special software performs automatic changing of samples and measurement of gamma spectra at constant interaction with the NAA database.

  15. Radiological Impact of Phosphogypsum Application in Agriculture

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dias, Nivea M. P.; Caires, Eduardo F.; Pires, Luiz F.

    2010-08-04

    Phosphogypsum (PG) contains radionuclides from {sup 238}U and {sup 232}Th decay series. Due to the presence of these radionuclides, many countries restricted the use of PG in agriculture, however there is not such restriction in Brazil. The main objective of this work was to evaluate the impact of PG application on {sup 226}Ra ({sup 238}U) and {sup 228}Ra ({sup 232}Th) concentrations in soil. Gamma-spectrometry was carried out using HPGe detector. No increment of {sup 226}Ra and {sup 228}Ra was observed for increasing PG doses. Average values found for {sup 226}Ra and {sup 228}Ra were respectively 37 Bq kg{sup -1} andmore » 57 Bq kg{sup -1}. The results showed that the increasing PG doses in the specific conditions of the experiment did not cause a significant increment of radionuclides.« less

  16. Novel method of measurement of radon exhalation from building materials.

    PubMed

    Awhida, A; Ujić, P; Vukanac, I; Đurašević, M; Kandić, A; Čeliković, I; Lončar, B; Kolarž, P

    2016-11-01

    In the era of the energy saving policy (i.e. more air tight doors and windows), the radon exhaled from building materials tends to increase its concentration in indoor air, which increases the importance of the measurement of radon exhalation from building materials. This manuscript presents a novel method of the radon exhalation measurement using only a HPGe detector or any other gamma spectrometer. Comparing it with the already used methods of radon exhalation measurements, this method provides the measurement of the emanation coefficient, the radon diffusion length and the radon exhalation rate, all within the same measurement, which additionally defines material's radon protective properties. Furthermore it does not necessitate additional equipment for radon or radon exhalation measurement, which simplifies measurement technique, and thus potentially facilitates introduction of legal obligation for radon exhalation determination in building materials. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. Lead Levels in Utah Eagles

    NASA Astrophysics Data System (ADS)

    Arnold, Michelle

    2006-10-01

    Lead is a health hazard to most animals, causing adverse effects to the nervous and reproductive systems if in sufficient quantity. Found in most fishing jigs and sinkers, as well as some ammunition used in hunting, this metal can poison wildlife such as eagles. Eagles are raptors, or predatory birds, and their lead exposure would most likely comes from their food -- a fish which has swallowed a sinker or lead shot in carrion (dead animal matter). As part of an ongoing project to investigate the environment lead levels in Utah, the bone lead levels in the wing bones of eagles have been measured for eagle carcasses found throughout Utah. The noninvasive technique of x-ray fluorescence was used, consisting of a Cd-109 radioactive source to activate lead atoms and a HPGe detector with digital electronics to collect the gamma spectra. Preliminary results for the eagles measured to date will be presented.

  18. Measurement of the total activity concentrations of Libyan oil scale

    NASA Astrophysics Data System (ADS)

    Da Silva, F. C. A.; Bradley, D. A.; Regan, P. H.; Rozaila, Z. Siti

    2017-08-01

    Twenty-three oil scale samples obtained from the Libyan oil and gas industry production facilities onshore have been measured using high-resolution gamma-ray spectrometry with a shielded HPGe detector, the work being carried out within the Environmental Radioactivity Laboratory at the University of Surrey. The main objectives of this work were to determine the extent to which the predominant radionuclides associated with the uranium and thorium natural decay chains were in secular equilibrium with their decay progeny, also to compare differences between the total activity concentrations (TAC) in secular equilibrium and disequilibrium and to evaluate the measured activities for the predominant gamma-ray emitting decay radionuclides within the 232Th and 238U chains. The oil scale NORM samples did not exhibit radioactive equilibrium between the decay progeny and longer-lived parent radionuclides of the 238U and 232Th series.

  19. Scintillation gamma spectrometer for analysis of hydraulic fracturing waste products.

    PubMed

    Ying, Leong; O'Connor, Frank; Stolz, John F

    2015-01-01

    Flowback and produced wastewaters from unconventional hydraulic fracturing during oil and gas explorations typically brings to the surface Naturally Occurring Radioactive Materials (NORM), predominantly radioisotopes from the U238 and Th232 decay chains. Traditionally, radiological sampling are performed by sending collected small samples for laboratory tests either by radiochemical analysis or measurements by a high-resolution High-Purity Germanium (HPGe) gamma spectrometer. One of the main isotopes of concern is Ra226 which requires an extended 21-days quantification period to allow for full secular equilibrium to be established for the alpha counting of its progeny daughter Rn222. Field trials of a sodium iodide (NaI) scintillation detector offers a more economic solution for rapid screenings of radiological samples. To achieve the quantification accuracy, this gamma spectrometer must be efficiency calibrated with known standard sources prior to field deployments to analyze the radioactivity concentrations in hydraulic fracturing waste products.

  20. In-beam γ -ray spectroscopy studies of medium-spin states in the odd-odd nucleus Re 186

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Matters, D. A.; Kondev, F. G.; Aoi, N.

    2017-07-01

    Excited states in 186Re with spins up to J = 12~ were investigated in two separate experiments using 186W(d, 2n) reactions at beam energies of 12.5 MeV and 14.5 MeV. Two- and three-fold γ-ray coincidence data were collected using the CAESAR and CAGRA spectrometers, respectively, each composed of Compton-suppressed HpGe detectors. Analysis of the data revealed rotational bands built on several two-quasiparticle intrinsic states, including a long-lived Kπ = (8+) isomer. Configuration assignments were supported by an analysis of in-band properties, such as |gK - gR| values. The excitation energies of the observed intrinsic states were compared with results frommore » multiquasiparticle blocking calculations, based on the Lipkin-Nogami pairing approach, that included contributions from the residual proton-neutron interactions.« less

  1. Cambio : a file format translation and analysis application for the nuclear response emergency community.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lasche, George P.

    2009-10-01

    Cambio is an application intended to automatically read and display any spectrum file of any format in the world that the nuclear emergency response community might encounter. Cambio also provides an analysis capability suitable for HPGe spectra when detector response and scattering environment are not well known. Why is Cambio needed: (1) Cambio solves the following problem - With over 50 types of formats from instruments used in the field and new format variations appearing frequently, it is impractical for every responder to have current versions of the manufacturer's software from every instrument used in the field; (2) Cambio convertsmore » field spectra to any one of several common formats that are used for analysis, saving valuable time in an emergency situation; (3) Cambio provides basic tools for comparing spectra, calibrating spectra, and isotope identification with analysis suited especially for HPGe spectra; and (4) Cambio has a batch processing capability to automatically translate a large number of archival spectral files of any format to one of several common formats, such as the IAEA SPE or the DHS N42. Currently over 540 analysts and members of the nuclear emergency response community worldwide are on the distribution list for updates to Cambio. Cambio users come from all levels of government, university, and commercial partners around the world that support efforts to counter terrorist nuclear activities. Cambio is Unclassified Unlimited Release (UUR) and distributed by internet downloads with email notifications whenever a new build of Cambio provides for new formats, bug fixes, or new or improved capabilities. Cambio is also provided as a DLL to the Karlsruhe Institute for Transuranium Elements so that Cambio's automatic file-reading capability can be included at the Nucleonica web site.« less

  2. The use of MCNP and gamma spectrometry in supporting the evaluation of NORM in Libyan oil pipeline scale

    NASA Astrophysics Data System (ADS)

    Habib, Ahmed S.; Bradley, D. A.; Regan, P. H.; Shutt, A. L.

    2010-07-01

    The accumulation of scales in production pipes is a common problem in the oil industry, reducing fluid flow and also leading to costly remedies and disposal issues. Typical materials found in such scale are sulphates and carbonates of calcium and barium, or iron sulphide. Radium arising from the uranium/thorium present in oil-bearing rock formations may replace the barium or calcium in these salts to form radium salts. This creates what is known as technologically enhanced naturally occurring radioactive material (TENORM or simply NORM). NORM is a serious environmental and health and safety issue arising from commercial oil and gas extraction operations. Whilst a good deal has been published on the characterisation and measurement of radioactive scales from offshore oil production, little information has been published regarding NORM associated with land-based facilities such as that of the Libyan oil industry. The ongoing investigation described in this paper concerns an assessment of NORM from a number of land based Libyan oil fields. A total of 27 pipe scale samples were collected from eight oil fields, from different locations in Libya. The dose rates, measured using a handheld survey meter positioned on sample surfaces, ranged from 0.1-27.3 μSv h -1. In the initial evaluations of the sample activity, use is being made of a portable HPGe based spectrometry system. To comply with the prevailing safety regulations of the University of Surrey, the samples are being counted in their original form, creating a need for correction of non-homogeneous sample geometries. To derive a detection efficiency based on the actual sample geometries, a technique has been developed using a Monte Carlo particle transport code (MCNPX). A preliminary activity determination has been performed using an HPGe portable detector system.

  3. A novel method for rapid in vitro radiobioassay

    NASA Astrophysics Data System (ADS)

    Crawford, Evan Bogert

    Rapid and accurate analysis of internal human exposure to radionuclides is essential to the effective triage and treatment of citizens who have possibly been exposed to radioactive materials in the environment. The two most likely scenarios in which a large number of citizens would be exposed are the detonation of a radiation dispersal device (RDD, "dirty bomb") or the accidental release of an isotope from an industrial source such as a radioisotopic thermal generator (RTG). In the event of the release and dispersion of radioactive materials into the environment in a large city, the entire population of the city -- including all commuting workers and tourists -- would have to be rapidly tested, both to satisfy the psychological needs of the citizens who were exposed to the mental trauma of a possible radiation dose, and to satisfy the immediate medical needs of those who received the highest doses and greatest levels of internal contamination -- those who would best benefit from rapid, intensive medical care. In this research a prototype rapid screening method to screen urine samples for the presence of up to five isotopes, both individually and in a mixture, has been developed. The isotopes used to develop this method are Co-60, Sr-90, Cs-137, Pu-238, and Am-241. This method avoids time-intensive chemical separations via the preparation and counting of a single sample on multiple detectors, and analyzing the spectra for isotope-specific markers. A rapid liquid-liquid separation using an organic extractive scintillator can be used to help quantify the activity of the alpha-emitting isotopes. The method provides quantifiable results in less than five minutes for the activity of beta/gamma-emitting isotopes when present in the sample at the intervention level as defined by the Centers for Disease Control and Prevention (CDC), and quantifiable results for the activity levels of alpha-emitting isotopes present at their respective intervention levels in approximately 30 minutes of sample preparation and counting time. Radiation detector spectra -- e.g. those from high-purity germanium (HPGe) gamma detectors and liquid scintillation detectors -- which contain decay signals from multiple isotopes often have overlapping signals: the counts from one isotope's decay can appear in energy channels associated with another isotope's decay, complicating the calculation of each isotope's activity. The uncertainties associated with analyzing these spectra have been traced in order to determine the effects of one isotope's count rate on the sensitivity and uncertainty associated with each other isotope. The method that was developed takes advantage of activated carbon filtration to eliminate quenching effects and to make the liquid scintillation spectra from different urine samples comparable. The method uses pulse-shape analysis to reduce the interference from beta emitters in the liquid scintillation spectrum and improve the minimum detectable activity (MDA) and minimum quantifiable activity (MQA) for alpha emitters. The method uses an HPGe detector to quantify the activity of gamma emitters, and subtract their isotopes' contributions to the liquid scintillation spectra via a calibration factor, such that the pure beta and pure alpha emitters can be identified and quantified from the resulting liquid scintillation spectra. Finally, the method optionally uses extractive scintillators to rapidly separate the alpha emitters from the beta emitters when the activity from the beta emitters is too great to detect or quantify the activity from the alpha emitters without such a separation. The method is able to detect and quantify all five isotopes, with uncertainties and biases usually in the 10-40% range, depending upon the isotopic mixtures and the activity ratios between each of the isotopes.

  4. The energy spectrum of neutrons from 7Li(d,n)8Be reaction at deuteron energy 2.9 MeV

    NASA Astrophysics Data System (ADS)

    Mitrofanov, Konstantin V.; Piksaikin, Vladimir M.; Zolotarev, Konstantin I.; Egorov, Andrey S.; Gremyachkin, Dmitrii E.

    2017-09-01

    The neutron beams generated at the electrostatic accelerators using nuclear reactions T(p,n)3He, D(d,n)3He, 7Li(p,n)7Be, T(d,n)4He, 7Li(d,n)8Be, 9Be(d,n)10B are widely used in neutron physics and in many practical applications. Among these reactions the least studied reactions are 7Li(d,n)8Be and 9Be(d,n)10B. The present work is devoted to the measurement of the neutron spectrum from 7Li(d,n)8Be reaction at 0∘ angle to the deuteron beam axis on the electrostatic accelerator Tandetron (JSC "SSC RF - IPPE") using activation method and a stilbene crystal scintillation detector. The first time ever 7Li(d,n)8Be reaction was measured by activation method. The target was a thick lithium layer on metallic backing. The energy of the incident deuteron was 2.9 MeV. As activation detectors a wide range of nuclear reactions were used: 27Al(n,p)27Mg, 27Al(n,α)24Na, 113In(n,n')113mIn, 115In(n,n')115mIn, 115In(n,γ)116mIn, 58Ni(n,p)58mCo, 58Ni(n,2n)57Ni, 197Au(n,γ)198Au, 197Au(n,2n)196Au, 59Co(n,p)59Fe, 59Co(n,2n)58m+gCo, 59Co (n,g)60Co. Measurement of the induced gamma-activity was carried out using HPGe detector Canberra GX5019 [1]. The up-to-date evaluations of the cross sections for these reactions were used in processing of the data. The program STAYSL was used to unfold the energy spectra. The neutron spectra obtained by activation detectors is consistent with the corresponding data measured by a stilbene crystal scintillation detector within their uncertainties.

  5. Calibration of the Accuscan II In Vivo System for I-125 Thyroid Counting

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ovard R. Perry; David L. Georgeson

    2011-07-01

    This report describes the March 2011 calibration of the Accuscan II HpGe In Vivo system for I-125 thyroid counting. The source used for the calibration was a DOE manufactured Am-241/Eu-152 source contained in a 22 ml vial BEA Am-241/Eu-152 RMC II-1 with energies from 26 keV to 344 keV. The center of the detector housing was positioned 64 inches from the vault floor. This position places the approximate center line of the detector housing at the center line of the source in the phantom thyroid tube. The energy and efficiency calibration were performed using an RMC II phantom (Appendix J).more » Performance testing was conducted using source BEA Am-241/Eu-152 RMC II-1 and Validation testing was performed using an I-125 source in a 30 ml vial (I-125 BEA Thyroid 002) and an ANSI N44.3 phantom (Appendix I). This report includes an overview introduction and records for the energy/FWHM and efficiency calibration including performance verification and validation counting. The Accuscan II system was successfully calibrated for counting the thyroid for I-125 and verified in accordance with ANSI/HPS N13.30-1996 criteria.« less

  6. Coulomb excitation of the proton-dripline nucleus Na20

    NASA Astrophysics Data System (ADS)

    Schumaker, M. A.; Cline, D.; Hackman, G.; Pearson, C. J.; Svensson, C. E.; Wu, C. Y.; Andreyev, A.; Austin, R. A. E.; Ball, G. C.; Bandyopadhyay, D.; Becker, J. A.; Boston, A. J.; Boston, H. C.; Buchmann, L.; Churchman, R.; Cifarelli, F.; Cooper, R. J.; Cross, D. S.; Dashdorj, D.; Demand, G. A.; Dimmock, M. R.; Drake, T. E.; Finlay, P.; Gallant, A. T.; Garrett, P. E.; Green, K. L.; Grint, A. N.; Grinyer, G. F.; Harkness, L. J.; Hayes, A. B.; Kanungo, R.; Lisetskiy, A. F.; Leach, K. G.; Lee, G.; Maharaj, R.; Martin, J.-P.; Moisan, F.; Morton, A. C.; Mythili, S.; Nelson, L.; Newman, O.; Nolan, P. J.; Orce, J. N.; Padilla-Rodal, E.; Phillips, A. A.; Porter-Peden, M.; Ressler, J. J.; Roy, R.; Ruiz, C.; Sarazin, F.; Scraggs, D. P.; Waddington, J. C.; Wan, J. M.; Whitbeck, A.; Williams, S. J.; Wong, J.

    2009-10-01

    The low-energy structure of the proton dripline nucleus Na20 has been studied using Coulomb excitation at the TRIUMF-ISAC radioactive ion beam facility. A 1.7-MeV/nucleon Na20 beam of ~5×106 ions/s was Coulomb excited by a 0.5-mg/cm2natTi target. Scattered beam and target particles were detected by the BAMBINO segmented Si detector while γ rays were detected by two TIGRESS HPGe clover detectors set perpendicular to the beam axis. Coulomb excitation from the 2+ ground state to the first excited 3+ and 4+ states was observed, and B(λL) values were determined using the 2+→0+ de-excitation in Ti48 as a reference. The resulting B(λL)↓ values are B(E2;3+→2+)=55±6e2fm4 (17.0±1.9 W.u.), B(E2;4+→2+)=35.7±5.7e2fm4 (11.1±1.8 W.u.), and B(M1;4+→3+)=0.154±0.030μN2 (0.086±0.017 W.u.). These measurements provide the first experimental determination of B(λL) values for this proton dripline nucleus of astrophysical interest.

  7. Technologically enhanced 210Pb and 210Po in iron and steel industry.

    PubMed

    Khater, Ashraf E M; Bakr, Wafaa F

    2011-05-01

    Iron and steel manufacture has been ranked as the largest industrial source of environmental contamination in the USA; the wastes generated in their production processes contain heavy elements that can be a source of contamination, and natural radionuclides that can produce an occupational and/or public radiological impact. In this work the potential occupational effective dose rate (μSv/y) due to inhalation in four integrated steel-making factories from Egypt has been evaluated, by assuming a well defined scenario and with basis in the (210)Pb and (210)Po activity concentrations determined in ore and wastes collected in the aforementioned factories. Activity concentrations, in Bq/kg, of (210)Pb and (210)Po, and leachable Pb and Fe were measured using gamma-ray spectrometry based on HPGe detector, alpha particle spectrometry based on PIPS detector, and inductively coupled plasma-mass spectrometry (ICP-MS). Levels of (210)Pb and (210)Po in the range of

  8. Development of a new type of germanium detector for dark matter searches

    NASA Astrophysics Data System (ADS)

    Wei, Wenzhao

    Monte Carlo simulation is an important tool used to develop a better understanding of important physical processes. This thesis describes three Monte Carlo simulations used to understand germanium detector response to low energy nuclear recoils and radiogenic backgrounds for direct dark matter searches. The first simulation is the verification of Barker-Mei model, a theoretical model for calculating the ionization efficiency for germanium detector for the energy range of 1 - 100 keV. Utilizing the shape analysis, a bin-to-bin comparison between simulation and experimental data was performed for verifying the accuracy of the Barker-Mei model. A percentage difference within 4% was achieved between data and simulation, which showed the validity of the Barker-Mei model. The second simulation is the study of a new type of germanium detector for n/gamma discrimination at 77 K with plasma time difference in pulse shape. Due to the poor time resolution, conventional P-type Point Contact (PPC) and coaxial germanium detectors are not capable of discriminating nuclear recoils from electron recoils. In this thesis, a new idea of using great detector granularity and plasma time difference in pulse shape to discriminate nuclear recoils from electron recoils with planar germanium detectors in strings was discussed. The anticipated sensitivity of this new detector array is shown for detecting dark matter. The last simulation is a study of a new type of germanium-detector array serving as a PMT screening facility for ultra-low background dark matter experiments using noble liquid xenon as detector material such LUX/LZ and XENON100/XENON1T. A well-shaped germanium detector array and a PMT were simulated to study the detector response to the signal and background for a better understanding of the radiogenic gamma rays from PMTs. The detector efficiency and other detector performance were presented in this work.

  9. A fast method for optical simulation of flood maps of light-sharing detector modules.

    PubMed

    Shi, Han; Du, Dong; Xu, JianFeng; Moses, William W; Peng, Qiyu

    2015-12-01

    Optical simulation of the detector module level is highly desired for Position Emission Tomography (PET) system design. Commonly used simulation toolkits such as GATE are not efficient in the optical simulation of detector modules with complicated light-sharing configurations, where a vast amount of photons need to be tracked. We present a fast approach based on a simplified specular reflectance model and a structured light-tracking algorithm to speed up the photon tracking in detector modules constructed with polished finish and specular reflector materials. We simulated conventional block detector designs with different slotted light guide patterns using the new approach and compared the outcomes with those from GATE simulations. While the two approaches generated comparable flood maps, the new approach was more than 200-600 times faster. The new approach has also been validated by constructing a prototype detector and comparing the simulated flood map with the experimental flood map. The experimental flood map has nearly uniformly distributed spots similar to those in the simulated flood map. In conclusion, the new approach provides a fast and reliable simulation tool for assisting in the development of light-sharing-based detector modules with a polished surface finish and using specular reflector materials.

  10. Detector Simulations with DD4hep

    NASA Astrophysics Data System (ADS)

    Petrič, M.; Frank, M.; Gaede, F.; Lu, S.; Nikiforou, N.; Sailer, A.

    2017-10-01

    Detector description is a key component of detector design studies, test beam analyses, and most of particle physics experiments that require the simulation of more and more different detector geometries and event types. This paper describes DD4hep, which is an easy-to-use yet flexible and powerful detector description framework that can be used for detector simulation and also extended to specific needs for a particular working environment. Linear collider detector concepts ILD, SiD and CLICdp as well as detector development collaborations CALICE and FCal have chosen to adopt the DD4hep geometry framework and its DDG4 pathway to Geant4 as its core simulation and reconstruction tools. The DDG4 plugins suite includes a wide variety of input formats, provides access to the Geant4 particle gun or general particles source and allows for handling of Monte Carlo truth information, eg. by linking hits and the primary particle that caused them, which is indispensable for performance and efficiency studies. An extendable array of segmentations and sensitive detectors allows the simulation of a wide variety of detector technologies. This paper shows how DD4hep allows to perform complex Geant4 detector simulations without compiling a single line of additional code by providing a palette of sub-detector components that can be combined and configured via compact XML files. Simulation is controlled either completely via the command line or via simple Python steering files interpreted by a Python executable. It also discusses how additional plugins and extensions can be created to increase the functionality.

  11. X-ray pinhole camera setups used in the Atomki ECR Laboratory for plasma diagnostics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rácz, R., E-mail: rracz@atomki.hu; Biri, S.; Pálinkás, J.

    Imaging of the electron cyclotron resonance (ECR) plasmas by using CCD camera in combination with a pinhole is a non-destructive diagnostics method to record the strongly inhomogeneous spatial density distribution of the X-ray emitted by the plasma and by the chamber walls. This method can provide information on the location of the collisions between warm electrons and multiple charged ions/atoms, opening the possibility to investigate the direct effect of the ion source tuning parameters to the plasma structure. The first successful experiment with a pinhole X-ray camera was carried out in the Atomki ECR Laboratory more than 10 years ago.more » The goal of that experiment was to make the first ECR X-ray photos and to carry out simple studies on the effect of some setting parameters (magnetic field, extraction, disc voltage, gas mixing, etc.). Recently, intensive efforts were taken to investigate now the effect of different RF resonant modes to the plasma structure. Comparing to the 2002 experiment, this campaign used wider instrumental stock: CCD camera with a lead pinhole was placed at the injection side allowing X-ray imaging and beam extraction simultaneously. Additionally, Silicon Drift Detector (SDD) and High Purity Germanium (HPGe) detectors were installed to characterize the volumetric X-ray emission rate caused by the warm and hot electron domains. In this paper, detailed comparison study on the two X-ray camera and detector setups and also on the technical and scientific goals of the experiments is presented.« less

  12. Simulation of the MoEDAL experiment

    NASA Astrophysics Data System (ADS)

    King, Matthew; MoEDAL Collaboration

    2016-04-01

    The MoEDAL experiment (Monopole and Exotics Detector at the LHC) is designed to directly search for magnetic monopoles and other highly ionising stable or meta-stable particles at the LHC. The MoEDAL detector comprises an array of plastic track detectors and aluminium trapping volumes around the P8 intersection region, opposite from the LHCb detector. TimePix devices are also installed for monitoring of the experiment. As MoEDAL mostly employs passive detectors the software development focusses on particle simulation, rather than digitisation or reconstruction. Here, we present the current status of the MoEDAL simulation software. Specifically, the development of a material description of the detector and simulations of monopole production and propagation at MoEDAL.

  13. A fast method for optical simulation of flood maps of light-sharing detector modules

    PubMed Central

    Shi, Han; Du, Dong; Xu, JianFeng; Moses, William W.; Peng, Qiyu

    2016-01-01

    Optical simulation of the detector module level is highly desired for Position Emission Tomography (PET) system design. Commonly used simulation toolkits such as GATE are not efficient in the optical simulation of detector modules with complicated light-sharing configurations, where a vast amount of photons need to be tracked. We present a fast approach based on a simplified specular reflectance model and a structured light-tracking algorithm to speed up the photon tracking in detector modules constructed with polished finish and specular reflector materials. We simulated conventional block detector designs with different slotted light guide patterns using the new approach and compared the outcomes with those from GATE simulations. While the two approaches generated comparable flood maps, the new approach was more than 200–600 times faster. The new approach has also been validated by constructing a prototype detector and comparing the simulated flood map with the experimental flood map. The experimental flood map has nearly uniformly distributed spots similar to those in the simulated flood map. In conclusion, the new approach provides a fast and reliable simulation tool for assisting in the development of light-sharing-based detector modules with a polished surface finish and using specular reflector materials. PMID:27660376

  14. A fast method for optical simulation of flood maps of light-sharing detector modules

    DOE PAGES

    Shi, Han; Du, Dong; Xu, JianFeng; ...

    2015-09-03

    Optical simulation of the detector module level is highly desired for Position Emission Tomography (PET) system design. Commonly used simulation toolkits such as GATE are not efficient in the optical simulation of detector modules with complicated light-sharing configurations, where a vast amount of photons need to be tracked. Here, we present a fast approach based on a simplified specular reflectance model and a structured light-tracking algorithm to speed up the photon tracking in detector modules constructed with polished finish and specular reflector materials. We also simulated conventional block detector designs with different slotted light guide patterns using the new approachmore » and compared the outcomes with those from GATE simulations. And while the two approaches generated comparable flood maps, the new approach was more than 200–600 times faster. The new approach has also been validated by constructing a prototype detector and comparing the simulated flood map with the experimental flood map. The experimental flood map has nearly uniformly distributed spots similar to those in the simulated flood map. In conclusion, the new approach provides a fast and reliable simulation tool for assisting in the development of light-sharing-based detector modules with a polished surface finish and using specular reflector materials.« less

  15. A SPECT system simulator built on the SolidWorks TM 3D-Design package.

    PubMed

    Li, Xin; Furenlid, Lars R

    2014-08-17

    We have developed a GPU-accelerated SPECT system simulator that integrates into instrument-design workflow [1]. This simulator includes a gamma-ray tracing module that can rapidly propagate gamma-ray photons through arbitrary apertures modeled by SolidWorks TM -created stereolithography (.STL) representations with a full complement of physics cross sections [2, 3]. This software also contains a scintillation detector simulation module that can model a scintillation detector with arbitrary scintillation crystal shape and light-sensor arrangement. The gamma-ray tracing module enables us to efficiently model aperture and detector crystals in SolidWorks TM and save them as STL file format, then load the STL-format model into this module to generate list-mode results of interacted gamma-ray photon information (interaction positions and energies) inside the detector crystals. The Monte-Carlo scintillation detector simulation module enables us to simulate how scintillation photons get reflected, refracted and absorbed inside a scintillation detector, which contributes to more accurate simulation of a SPECT system.

  16. A SPECT system simulator built on the SolidWorksTM 3D design package

    NASA Astrophysics Data System (ADS)

    Li, Xin; Furenlid, Lars R.

    2014-09-01

    We have developed a GPU-accelerated SPECT system simulator that integrates into instrument-design work flow [1]. This simulator includes a gamma-ray tracing module that can rapidly propagate gamma-ray photons through arbitrary apertures modeled by SolidWorksTM-created stereolithography (.STL) representations with a full com- plement of physics cross sections [2, 3]. This software also contains a scintillation detector simulation module that can model a scintillation detector with arbitrary scintillation crystal shape and light-sensor arrangement. The gamma-ray tracing module enables us to efficiently model aperture and detector crystals in SolidWorksTM and save them as STL file format, then load the STL-format model into this module to generate list-mode results of interacted gamma-ray photon information (interaction positions and energies) inside the detector crystals. The Monte-Carlo scintillation detector simulation module enables us to simulate how scintillation photons get reflected, refracted and absorbed inside a scintillation detector, which contributes to more accurate simulation of a SPECT system.

  17. The Application of SNiPER to the JUNO Simulation

    NASA Astrophysics Data System (ADS)

    Lin, Tao; Zou, Jiaheng; Li, Weidong; Deng, Ziyan; Fang, Xiao; Cao, Guofu; Huang, Xingtao; You, Zhengyun; JUNO Collaboration

    2017-10-01

    The JUNO (Jiangmen Underground Neutrino Observatory) is a multipurpose neutrino experiment which is designed to determine neutrino mass hierarchy and precisely measure oscillation parameters. As one of the important systems, the JUNO offline software is being developed using the SNiPER software. In this proceeding, we focus on the requirements of JUNO simulation and present the working solution based on the SNiPER. The JUNO simulation framework is in charge of managing event data, detector geometries and materials, physics processes, simulation truth information etc. It glues physics generator, detector simulation and electronics simulation modules together to achieve a full simulation chain. In the implementation of the framework, many attractive characteristics of the SNiPER have been used, such as dynamic loading, flexible flow control, multiple event management and Python binding. Furthermore, additional efforts have been made to make both detector and electronics simulation flexible enough to accommodate and optimize different detector designs. For the Geant4-based detector simulation, each sub-detector component is implemented as a SNiPER tool which is a dynamically loadable and configurable plugin. So it is possible to select the detector configuration at runtime. The framework provides the event loop to drive the detector simulation and interacts with the Geant4 which is implemented as a passive service. All levels of user actions are wrapped into different customizable tools, so that user functions can be easily extended by just adding new tools. The electronics simulation has been implemented by following an event driven scheme. The SNiPER task component is used to simulate data processing steps in the electronics modules. The electronics and trigger are synchronized by triggered events containing possible physics signals. The JUNO simulation software has been released and is being used by the JUNO collaboration to do detector design optimization, event reconstruction algorithm development and physics sensitivity studies.

  18. Simulation of radiation environment for the LHeC detector

    NASA Astrophysics Data System (ADS)

    Nayaz, Abdullah; Piliçer, Ercan; Joya, Musa

    2017-02-01

    The detector response and simulation of radiation environment for the Large Hadron electron Collider (LHeC) baseline detector is estimated to predict its performance over the lifetime of the project. In this work, the geometry of the LHeC detector, as reported in LHeC Conceptual Design Report (CDR), built in FLUKA Monte Carlo tool in order to simulate the detector response and radiation environment. For this purpose, events of electrons and protons with high enough energy were sent isotropically from interaction point of the detector. As a result, the detector response and radiation background for the LHeC detector, with different USRBIN code (ENERGY, HADGT20M, ALL-CHAR, ALL-PAR) in FLUKA, are presented.

  19. Attributes from NMIS Time Coincidence, Fast-Neutron Imaging, Fission Mapping, And Gamma-Ray Spectrometry Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Swift, Alicia L; Grogan, Brandon R; Mullens, James Allen

    This work tests a systematic procedure for analyzing data acquired by the Nuclear Materials Identification System (NMIS) at Oak Ridge National Laboratory with fast-neutron imaging and high-purity germanium (HPGe) gamma spectrometry capabilities. NMIS has been under development by the US Department of Energy Office of Nuclear Verification since the mid-1990s, and prior to that by the National Nuclear Security Administration Y-12 National Security Complex, with NMIS having been used at Y-12 for template matching to confirm inventory and receipts. In this present work, a complete set of NMIS time coincidence, fast-neutron imaging, fission mapping, and HPGe gamma-ray spectrometry data wasmore » obtained from Monte Carlo simulations for a configuration of fissile and nonfissile materials. The data were then presented for analysis to someone who had no prior knowledge of the unknown object to accurately determine the description of the object by applying the previously-mentioned procedure to the simulated data. The best approximation indicated that the unknown object was composed of concentric cylinders: a void inside highly enriched uranium (HEU) (84.7 {+-} 1.9 wt % {sup 235}U), surrounded by depleted uranium, surrounded by polyethylene. The final estimation of the unknown object had the correct materials and geometry, with error in the radius estimates of material regions varying from 1.58% at best and 4.25% at worst; error in the height estimates varied from 2% to 12%. The error in the HEU enrichment estimate was 5.9 wt % (within 2.5{sigma} of the true value). The accuracies of the determinations could be adequate for arms control applications. Future work will apply this iterative reconstructive procedure to other unknown objects to further test and refine it.« less

  20. Comparing performances of a CdTe X-ray spectroscopic detector and an X-ray dual-energy sandwich detector

    NASA Astrophysics Data System (ADS)

    Gorecki, A.; Brambilla, A.; Moulin, V.; Gaborieau, E.; Radisson, P.; Verger, L.

    2013-11-01

    Multi-energy (ME) detectors are becoming a serious alternative to classical dual-energy sandwich (DE-S) detectors for X-ray applications such as medical imaging or explosive detection. They can use the full X-ray spectrum of irradiated materials, rather than disposing only of low and high energy measurements, which may be mixed. In this article, we intend to compare both simulated and real industrial detection systems, operating at a high count rate, independently of the dimensions of the measurements and independently of any signal processing methods. Simulations or prototypes of similar detectors have already been compared (see [1] for instance), but never independently of estimation methods and never with real detectors. We have simulated both an ME detector made of CdTe - based on the characteristics of the MultiX ME100 and - a DE-S detector - based on the characteristics of the Detection Technology's X-Card 1.5-64DE model. These detectors were compared to a perfect spectroscopic detector and an optimal DE-S detector. For comparison purposes, two approaches were investigated. The first approach addresses how to distinguise signals, while the second relates to identifying materials. Performance criteria were defined and comparisons were made over a range of material thicknesses and with different photon statistics. Experimental measurements in a specific configuration were acquired to checks simulations. Results showed good agreement between the ME simulation and the ME100 detector. Both criteria seem to be equivalent, and the ME detector performs 3.5 times better than the DE-S detector with same photon statistics based on simulations and experimental measurements. Regardless of the photon statistics ME detectors appeared more efficient than DE-S detectors for all material thicknesses between 1 and 9 cm when measuring plastics with an attenuation signature close that of explosive materials. This translates into an improved false detection rate (FDR): DE-S detectors have an FDR 2.87±0.03-fold higher than ME detectors for 4 cm of POM with 20 000 incident photons, when identifications are screened against a two-material base.

  1. Experimental measurement and Monte Carlo assessment of Argon-41 production in a PET cyclotron facility.

    PubMed

    Infantino, Angelo; Valtieri, Lorenzo; Cicoria, Gianfranco; Pancaldi, Davide; Mostacci, Domiziano; Marengo, Mario

    2015-12-01

    In a medical cyclotron facility, (41)Ar (t1/2 = 109.34 m) is produced by the activation of air due to the neutron flux during irradiation, according to the (40)Ar(n,γ)(41)Ar reaction; this is particularly relevant in widely diffused high beam current cyclotrons for the production of PET radionuclides. While theoretical estimations of the (41)Ar production have been published, no data are available on direct experimental measurements for a biomedical cyclotron. In this work, we describe a sampling methodology and report the results of an extensive measurement campaign. Furthermore, the experimental results are compared with Monte Carlo simulations performed with the FLUKA code. To measure (41)Ar activity, air samples were taken inside the cyclotron bunker in sealed Marinelli beakers, during the routine production of (18)F with a 16.5 MeV GE-PETtrace cyclotron; this sampling thus reproduces a situation of absence of air changes. Samples analysis was performed in a gamma-ray spectrometry system equipped with HPGe detector. Monte Carlo assessment of the (41)Ar saturation yield was performed directly using the standard FLUKA score RESNUCLE, and off-line by the convolution of neutron fluence with cross section data. The average (41)Ar saturation yield per one liter of air of (41)Ar, measured in gamma-ray spectrometry, resulted to be 3.0 ± 0.6 Bq/µA*dm(3) while simulations gave a result of 6.9 ± 0.3 Bq/µA*dm(3) in the direct assessment and 6.92 ± 0.22 Bq/µA*dm(3) by the convolution neutron fluence-to-cross section. Copyright © 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  2. Simulation of image detectors in radiology for determination of scatter-to-primary ratios using Monte Carlo radiation transport code MCNP/MCNPX.

    PubMed

    Smans, Kristien; Zoetelief, Johannes; Verbrugge, Beatrijs; Haeck, Wim; Struelens, Lara; Vanhavere, Filip; Bosmans, Hilde

    2010-05-01

    The purpose of this study was to compare and validate three methods to simulate radiographic image detectors with the Monte Carlo software MCNP/MCNPX in a time efficient way. The first detector model was the standard semideterministic radiography tally, which has been used in previous image simulation studies. Next to the radiography tally two alternative stochastic detector models were developed: A perfect energy integrating detector and a detector based on the energy absorbed in the detector material. Validation of three image detector models was performed by comparing calculated scatter-to-primary ratios (SPRs) with the published and experimentally acquired SPR values. For mammographic applications, SPRs computed with the radiography tally were up to 44% larger than the published results, while the SPRs computed with the perfect energy integrating detectors and the blur-free absorbed energy detector model were, on the average, 0.3% (ranging from -3% to 3%) and 0.4% (ranging from -5% to 5%) lower, respectively. For general radiography applications, the radiography tally overestimated the measured SPR by as much as 46%. The SPRs calculated with the perfect energy integrating detectors were, on the average, 4.7% (ranging from -5.3% to -4%) lower than the measured SPRs, whereas for the blur-free absorbed energy detector model, the calculated SPRs were, on the average, 1.3% (ranging from -0.1% to 2.4%) larger than the measured SPRs. For mammographic applications, both the perfect energy integrating detector model and the blur-free energy absorbing detector model can be used to simulate image detectors, whereas for conventional x-ray imaging using higher energies, the blur-free energy absorbing detector model is the most appropriate image detector model. The radiography tally overestimates the scattered part and should therefore not be used to simulate radiographic image detectors.

  3. Optimization of Single-Sided Charge-Sharing Strip Detectors

    NASA Technical Reports Server (NTRS)

    Hamel, L.A.; Benoit, M.; Donmez, B.; Macri, J. R.; McConnell, M. L.; Ryan, J. M.; Narita, T.

    2006-01-01

    Simulation of the charge sharing properties of single-sided CZT strip detectors with small anode pads are presented. The effect of initial event size, carrier repulsion, diffusion, drift, trapping and detrapping are considered. These simulations indicate that such a detector with a 150 m pitch will provide good charge sharing between neighboring pads. This is supported by a comparison of simulations and measurements for a similar detector with a coarser pitch of 225 m that could not provide sufficient sharing. The performance of such a detector used as a gamma-ray imager is discussed.

  4. Precise 238U(n,2n)237U reaction cross-section measurements using the activation facility at TUNL

    NASA Astrophysics Data System (ADS)

    Krishichayan, Fnu; Bhike, M.; Tornow, W.

    2014-09-01

    Accurate neutron-induced 238U(n,2n)237U reaction data are required for many practical applications, especially in the field of nuclear energy, including advanced heavy water reactors, where 238U is used as the breeding material to regenerate the fissile material 239Pu. Precise (n,2n) cross-section measurements of 238U are underway at TUNL with mono-energetic neutrons in the 8.0 to 14.0 MeV energy range in steps of 0.25 MeV using the activation technique. After activation of the 0.5 inch diameter and 442 mg 238U foil, the activity of the 208 keV characteristic γ-line is tracked for 6 weeks with a high efficient HPGe clover detector to determine the initial activity needed for the cross-section determination. Results of the cross-section measurements, determined relative to 27Al and 197Au neutron activation monitor foils, and the comparison with theoretical models will be presented during the meeting.

  5. Measurement of Fission Product Yields from Fast-Neutron Fission

    NASA Astrophysics Data System (ADS)

    Arnold, C. W.; Bond, E. M.; Bredeweg, T. A.; Fowler, M. M.; Moody, W. A.; Rusev, G.; Vieira, D. J.; Wilhelmy, J. B.; Becker, J. A.; Henderson, R.; Kenneally, J.; Macri, R.; McNabb, D.; Ryan, C.; Sheets, S.; Stoyer, M. A.; Tonchev, A. P.; Bhatia, C.; Bhike, M.; Fallin, B.; Gooden, M. E.; Howell, C. R.; Kelley, J. H.; Tornow, W.

    2014-09-01

    One of the aims of the Stockpile Stewardship Program is a reduction of the uncertainties on fission data used for analyzing nuclear test data [1,2]. Fission products such as 147Nd are convenient for determining fission yields because of their relatively high yield per fission (about 2%) and long half-life (10.98 days). A scientific program for measuring fission product yields from 235U,238U and 239Pu targets as a function of bombarding neutron energy (0.1 to 15 MeV) is currently underway using monoenergetic neutron beams produced at the 10 MV Tandem Accelerator at TUNL. Dual-fission chambers are used to determine the rate of fission in targets during activation. Activated targets are counted in highly shielded HPGe detectors over a period of several weeks to identify decaying fission products. To date, data have been collected at neutron bombarding energies 4.6, 9.0, 14.5 and 14.8 MeV. Experimental methods and data reduction techniques are discussed, and some preliminary results are presented.

  6. High-precision half-life measurements for the superallowed Fermi β+ emitter 14O

    NASA Astrophysics Data System (ADS)

    Laffoley, A. T.; Svensson, C. E.; Andreoiu, C.; Austin, R. A. E.; Ball, G. C.; Blank, B.; Bouzomita, H.; Cross, D. S.; Diaz Varela, A.; Dunlop, R.; Finlay, P.; Garnsworthy, A. B.; Garrett, P. E.; Giovinazzo, J.; Grinyer, G. F.; Hackman, G.; Hadinia, B.; Jamieson, D. S.; Ketelhut, S.; Leach, K. G.; Leslie, J. R.; Tardiff, E.; Thomas, J. C.; Unsworth, C.

    2013-07-01

    The half-life of the superallowed Fermi β+ emitter 14O has been determined via simultaneous direct β and γ counting experiments at TRIUMF's Isotope Separator and Accelerator (ISAC) facility. A γ-ray counting measurement was performed by detecting the 2312.6-keV γ rays emitted from an excited state of the daughter 14N following the implantation of samples at the center of the 8π γ-ray spectrometer, a spherical array of 20 high-purity germanium (HPGe) detectors. A simultaneous β counting experiment was performed using a fast plastic scintillator positioned behind the implantation site with a solid angle coverage of ˜20%. The results, T1/2(β)=70.610±0.030s and T1/2(γ)=70.632±0.094s, form a consistent set and, together with eight previous measurements, establish a new average for the 14O half-life of T1/2=70.619±0.011s with a reduced χ2 of 0.99.

  7. Measurement of the Ir-191,193(n,2n)Ir-190,192 Reaction Cross Section Between 9.0 and 16.5 MeV

    NASA Astrophysics Data System (ADS)

    Wildenhain, Elizabeth; Finch, Sean; Tornow, Werner; Krishichayan, F.

    2017-09-01

    Iridium is one of the elements prioritized by Nonproliferation and Homeland Security agencies. In addition, Ir-192 is being used in various medical treatments. Improved data and corresponding evaluations of neutron-induced reactions on the iridium isotopes are required to meet the demands of several applications of societal interest. This study measured the cross section of the Ir-191,193(n, 2n)Ir-190,192 reactions at energies from 9.0 to 16.5 MeV using the activation technique. Natural Ir samples [Ir-191 37.3%, Ir-193 62.7%] were sandwiched between Au-197 monitor foils and irradiated with monoenergetic neutron beams at the tandem facility of the Triangle Universities Nuclear Laboratory (TUNL). Gamma rays from the irradiated samples were counted in TUNL's low background facility using high-efficient HPGe detectors. Measured cross-section data are compared to previous data and to predictions from nuclear data libraries (e.g. ENDF). Research at TUNL funded by the NSF.

  8. Implementation of k0-INAA standardisation at ITU TRIGA Mark II research reactor, Turkey based on k0-IAEA software

    NASA Astrophysics Data System (ADS)

    Esen, Ayse Nur; Haciyakupoglu, Sevilay

    2016-02-01

    The purpose of this study is to test the applicability of k0-INAA method at the Istanbul Technical University TRIGA Mark II research reactor. The neutron spectrum parameters such as epithermal neutron flux distribution parameter (α), thermal to epithermal neutron flux ratio (f) and thermal neutron flux (φth) were determined at the central irradiation channel of the ITU TRIGA Mark II research reactor using bare triple-monitor method. HPGe detector calibrations and calculations were carried out by k0-IAEA software. The α, f and φth values were calculated to be -0.009, 15.4 and 7.92·1012 cm-2 s-1, respectively. NIST SRM 1633b coal fly ash and intercomparison samples consisting of clay and sandy soil samples were used to evaluate the validity of the method. For selected elements, the statistical evaluation of the analysis results was carried out by z-score test. A good agreement between certified/reported and experimental values was obtained.

  9. Detection of pulsed bremsstrahlung-induced prompt neutron capture gamma rays with a HPGe detector

    NASA Astrophysics Data System (ADS)

    Jones, James L.

    1997-02-01

    The Idaho National Engineering Laboratory (INEL) is developing a novel photoneutron-based nondestructive evaluation technique which uses a pulsed, high-energy electron accelerator and gamma-ray spectrometry. Highly penetrating pulses of bremsstrahlung photons are produced by each pulse of electrons. Interrogating neutrons are generated by the bremsstrahlung photons interacting within a photoneutron source material. The interactions of the neutrons within a target result in the emission of elemental characteristic gamma-rays. Spectrometry is performed by analyzing the photoneutron-induced, prompt gama-rays acquired between accelerator pulses with a unique, high- purity germanium gamma-ray detection system using a modified transistor reset preamplifier. The detection system, the experimental configuration, and the accelerator operation used to characterize the detection systems performance are described. Using a 6.5-MeV electron accelerator and a beryllium metal photoneutron source, gamma-ray spectra were successfully acquired for Al, Cu, polyethylene, NaCl, and depleted uranium targets as soon as 30 microsecond(s) after each bremsstrahlung flash.

  10. PB-210 concentrations in cigarettes tobaccos and radiation doses to the smokers.

    PubMed

    Tahir, S N A; Alaamer, A S

    2008-01-01

    Cigarette smoking is a source of radiation exposure due to the concentrations of natural radionuclides in the tobacco leaves. From the health point of view, measurement of (210)Pb and (210)Po contents in cigarette tobacco is important to assess the radiological effects associated with the tobacco smoking for the smokers. In the present study, activity concentrations of (210)Pb, which is a (210)Po precursor in the (238)U-decay series, were measured in cigarette tobaccos. Samples of nine different commonly sold brands of cigarette tobaccos were analysed by employing a planar high purity germanium (HPGe) low background detector. Activity concentrations of (210)Pb were measured from its gamma peak at 47 keV. Mean activity concentration of (210)Pb was measured to be 13 +/- 4 Bq kg(-1) from all samples analysed. The annual committed effective dose for a smoker and the collective committed effective dose corresponding to annual cigarettes production were estimated to be 64 +/- 20 microSv and 0.6 x 10(2) man-Sv, respectively.

  11. Assessment of Natural Radioactivity and radiation hazards in beach sand samples from Kanyakumari District, TamilNadu

    NASA Astrophysics Data System (ADS)

    Ajithra, A. K.; Shanthi, G.

    2016-07-01

    Natural radionuclides of terrestrial origin have very long half - lives or driven from very long - lived parent radionuclides, which have been created in stellar processes before the earth formation. The study of natural radioactivity in marine and coastal environments is of significant importance for better understanding of oceanographic and sedimentological processes. The sampling sites are selected to cover randomly to cover the southern part. The soil samples have been collected in beach sides. In situ gamma measurements were conducted using a high-purity germanium (HPGe) detector (coaxial cylinder of 50.1 mm in diameter and 44 mm in length) with a relative efficiency of 50% and an energy resolution (FWHM) of 1.8 keV at the 1.33 MeV reference transition of 60Co. The measurements shows that the values of the absorbed dose rates in air in the investigated area are lower than the recommended limit by the United Nations Scientific Committee on the Effect of Atomic Radiation.

  12. Determination of the energy transitions and half-lives of Rubidium nuclei

    NASA Astrophysics Data System (ADS)

    Biçer, Ahmet; Manisa, Kaan; Engin Çalık, Abdullah; Erdoğan, Mehmet; Şen, Mürsel; Bircan, Hasan; Dapo, Haris; Boztosun, Ismail

    2018-03-01

    The photonuclear reactions, first extensively studied in the 1970's and performed using the gamma rays obtained via bremsstrahlung, are a standard nuclear physics experiment. In this study, a non-enriched Rubidium sample was irradiated with photons produced by a clinical linear electron accelerator (cLINACs) with energies up to 18 MeV with the aim of activating it through photonuclear reactions. The activated sample was measured with a high purity germanium detector (HPGe) with the aim of measuring the transition energies and half-lives. The spectroscopic analysis performed on the obtained data yielded high quality results for the transition energies with precision matching or surpassing the literature data. For the half-lives the results were consistent with the literature, most notably the half-life of 84mRb decay was determined as 20.28(2) m. The results for both energies and half-lives further show that the clinical linear accelerators can be successfully used as an efficient tool in experimental nuclear research endeavors.

  13. Production of 13N by 12C(d,n)13N reaction in a medium energy plasma focus.

    PubMed

    Shirani, B; Abbasi, F; Nikbakht, M

    2013-04-01

    This paper explores the production of (13)N by bombardment of a carbon target by high energy deuterons in a medium energy plasma focus. A set of experiments in the energy range of 2.7-3.1kJ and initial pressure of 200-700Pa, with three or five shots in each experiment, was performed. A HPGe detector was used for gamma spectroscopy, and 511keV photons emitted by positron annihilation were utilized to measure the (13)N radioactivity. The highest activity of (13)N in these experiments was 14Bq which was acquired after five shots at a pressure of 450Pa and a 3.1kJ stored energy. Calculations based on thick target yield showed that at least 1.9×10(9) deuterons with energies higher than 330keV were ejected from the pinch region. Copyright © 2013 Elsevier Ltd. All rights reserved.

  14. Determination of neutron capture cross sections of 232Th at 14.1 MeV and 14.8 MeV using the neutron activation method

    NASA Astrophysics Data System (ADS)

    Lan, Chang-Lin; Zhang, Yi; Lv, Tao; Xie, Bao-Lin; Peng, Meng; Yao, Ze-En; Chen, Jin-Gen; Kong, Xiang-Zhong

    2017-04-01

    The 232Th(n, γ)233Th neutron capture reaction cross sections were measured at average neutron energies of 14.1 MeV and 14.8 MeV using the activation method. The neutron flux was determined using the monitor reaction 27Al(n,α)24Na. The induced gamma-ray activities were measured using a low background gamma ray spectrometer equipped with a high resolution HPGe detector. The experimentally determined cross sections were compared with the data in the literature, and the evaluated data of ENDF/B-VII.1, JENDL-4.0u+, and CENDL-3.1. The excitation functions of the 232Th(n,γ)233Th reaction were also calculated theoretically using the TALYS1.6 computer code. Supported by Chinese TMSR Strategic Pioneer Science and Technology Project-The Th-U Fuel Physics Term (XDA02010100) and National Natural Science Foundation of China (11205076, 21327801)

  15. Measurements of the thermal neutron cross-section and resonance integral for the 108Pd(n,γ)109Pd reaction

    NASA Astrophysics Data System (ADS)

    Hien, Nguyen Thi; Kim, Guinyun; Kim, Kwangsoo; Do, Nguyen Van; Khue, Pham Duc; Thanh, Kim Tien; Shin, Sung-Gyun; Cho, Moo-Hyun

    2018-06-01

    The thermal neutron capture cross-section (σ0) and resonance integral (I0) of the 108Pd(n,γ)109Pd reaction have been measured relative to that of the monitor reaction 197Au(n,γ)198Au. The measurements were carried out using the neutron activation with the cadmium ratio method. Both the samples and monitors were irradiated with and without cadmium cover of 0.5 mm thickness. The induced activities of the reaction products were measured with a well calibrated HPGe γ-ray detector. In order to improve the accuracy of the results, the necessary corrections for the counting losses were made. The thermal neutron capture cross-section and resonance integral of the 108Pd(n,γ)109Pd reaction were determined to be σ0,Pd = 8.68 ± 0.41 barn and I0,Pd = 245.6 ± 24.8 barn, respectively. The obtained results are compared with literature values and discussed.

  16. The NOvA simulation chain

    NASA Astrophysics Data System (ADS)

    Aurisano, A.; Backhouse, C.; Hatcher, R.; Mayer, N.; Musser, J.; Patterson, R.; Schroeter, R.; Sousa, A.

    2015-12-01

    The NOνA experiment is a two-detector, long-baseline neutrino experiment operating in the recently upgraded NuMI muon neutrino beam. Simulating neutrino interactions and backgrounds requires many steps including: the simulation of the neutrino beam flux using FLUKA and the FLUGG interface; cosmic ray generation using CRY; neutrino interaction modeling using GENIE; and a simulation of the energy deposited in the detector using GEANT4. To shorten generation time, the modeling of detector-specific aspects, such as photon transport, detector and electronics noise, and readout electronics, employs custom, parameterized simulation applications. We will describe the NOνA simulation chain, and present details on the techniques used in modeling photon transport near the ends of cells, and in developing a novel data-driven noise simulation. Due to the high intensity of the NuMI beam, the Near Detector samples a high rate of muons originating in the surrounding rock. In addition, due to its location on the surface at Ash River, MN, the Far Detector collects a large rate (˜ 140 kHz) of cosmic muons. We will discuss the methods used in NOνA for overlaying rock muons and cosmic ray muons with simulated neutrino interactions and show how realistically the final simulation reproduces the preliminary NOνA data.

  17. The NO vA simulation chain

    DOE PAGES

    Aurisano, A.; Backhouse, C.; Hatcher, R.; ...

    2015-12-23

    The NO vA experiment is a two-detector, long-baseline neutrino experiment operating in the recently upgraded NuMI muon neutrino beam. Simulating neutrino interactions and backgrounds requires many steps including: the simulation of the neutrino beam flux using FLUKA and the FLUGG interface, cosmic ray generation using CRY, neutrino interaction modeling using GENIE, and a simulation of the energy deposited in the detector using GEANT4. To shorten generation time, the modeling of detector-specific aspects, such as photon transport, detector and electronics noise, and readout electronics, employs custom, parameterized simulation applications. We will describe the NO vA simulation chain, and present details onmore » the techniques used in modeling photon transport near the ends of cells, and in developing a novel data-driven noise simulation. Due to the high intensity of the NuMI beam, the Near Detector samples a high rate of muons originating in the surrounding rock. In addition, due to its location on the surface at Ash River, MN, the Far Detector collects a large rate ((˜) 140 kHz) of cosmic muons. Furthermore, we will discuss the methods used in NO vA for overlaying rock muons and cosmic ray muons with simulated neutrino interactions and show how realistically the final simulation reproduces the preliminary NO vA data.« less

  18. The Majorana Demonstrator: A search for neutrinoless double-beta decay of germanium-76

    NASA Astrophysics Data System (ADS)

    Elliott, S. R.; Abgrall, N.; Aguayo, E.; Avignone, F. T., III; Barabash, A. S.; Bertrand, F. E.; Boswell, M.; Brudanin, V.; Busch, M.; Caldwell, A. S.; Chan, Y.-D.; Christofferson, C. D.; Combs, D. C.; Detwiler, J. A.; Doe, P. J.; Efremenko, Yu.; Egorov, V.; Ejiri, H.; Esterline, J.; Fast, J. E.; Finnerty, P.; Fraenkle, F. M.; Galindo-Uribarri, A.; Giovanetti, G. K.; Goett, J.; Green, M. P.; Gruszko, J.; Guiseppe, V. E.; Gusev, K.; Hallin, A. L.; Hazama, R.; Hegai, A.; Henning, R.; Hoppe, E. W.; Howard, S.; Howe, M. A.; Keeter, K. J.; Kidd, M. F.; Kochetov, O.; Konovalov, S. I.; Kouzes, R. T.; LaFerriere, B. D.; Leon, J.; Leviner, L. E.; Loach, J. C.; MacMullin, S.; Martin, R. D.; Mertens, S.; Mizouni, L.; Nomachi, M.; Orrell, J. L.; O'Shaughnessy, C.; Overman, N. R.; Phillips, D. G., II; Poon, A. W. P.; Pushkin, K.; Radford, D. C.; Rielage, K.; Robertson, R. G. H.; Ronquest, M. C.; Schubert, A. G.; Shanks, B.; Shima, T.; Shirchenko, M.; Snavely, K. J.; Snyder, N.; Soin, A.; Strain, J.; Suriano, A. M.; Timkin, V.; Tornow, W.; Varner, R. L.; Vasilyev, S.; Vetter, K.; Vorren, K.; White, B. R.; Wilkerson, J. F.; Xu, W.; Yakushev, E.; Young, A. R.; Yu, C.-H.; Yumatov, V.

    2013-12-01

    The Majorana collaboration is searching for neutrinoless double beta decay using 76Ge, which has been shown to have a number of advantages in terms of sensitivities and backgrounds. The observation of neutrinoless double-beta decay would show that lepton number is violated and that neutrinos are Majorana particles and would simultaneously provide information on neutrino mass. Attaining sensitivities for neutrino masses in the inverted hierarchy region, 15 - 50 meV, will require large, tonne-scale detectors with extremely low backgrounds, at the level of ˜1 count/t-y or lower in the region of the signal. The Majorana collaboration, with funding support from DOE Office of Nuclear Physics and NSF Particle Astrophysics, is constructing the Demonstrator, an array consisting of 40 kg of p-type point-contact high-purity germanium (HPGe) detectors, of which ˜30 kg will be enriched to 87% in 76Ge. The Demonstrator is being constructed in a clean room laboratory facility at the 4850' level (4300 m.w.e.) of the Sanford Underground Research Facility (SURF) in Lead, SD. It utilizes a compact graded shield approach with the inner portion consisting of ultra-clean Cu that is being electroformed and machined underground. The primary aim of the Demonstrator is to show the feasibility of a future tonne-scale measurement in terms of backgrounds and scalability.

  19. High-precision branching-ratio measurement for the superallowed β+ emitter 74Rb

    NASA Astrophysics Data System (ADS)

    Dunlop, R.; Ball, G. C.; Leslie, J. R.; Svensson, C. E.; Towner, I. S.; Andreoiu, C.; Chagnon-Lessard, S.; Chester, A.; Cross, D. S.; Finlay, P.; Garnsworthy, A. B.; Garrett, P. E.; Glister, J.; Hackman, G.; Hadinia, B.; Leach, K. G.; Rand, E. T.; Starosta, K.; Tardiff, E. R.; Triambak, S.; Williams, S. J.; Wong, J.; Yates, S. W.; Zganjar, E. F.

    2013-10-01

    A high-precision branching-ratio measurement for the superallowed β+ decay of 74Rb was performed at the TRIUMF Isotope Separator and Accelerator (ISAC) radioactive ion-beam facility. The scintillating electron-positron tagging array (SCEPTAR), composed of 10 thin plastic scintillators, was used to detect the emitted β particles; the 8π spectrometer, an array of 20 Compton-suppressed HPGe detectors, was used for detecting γ rays that were emitted following Gamow-Teller and nonanalog Fermi β+ decays of 74Rb; and the Pentagonal Array of Conversion Electron Spectrometers (PACES), an array of 5 Si(Li) detectors, was employed for measuring β-delayed conversion electrons. Twenty-three excited states were identified in 74Kr following 8.241(4)×108 detected 74Rb β decays. A total of 58 γ-ray and electron transitions were placed in the decay scheme, allowing the superallowed branching ratio to be determined as B0=99.545(31)%. Combined with previous half-life and Q-value measurements, the superallowed branching ratio measured in this work leads to a superallowed ft value of 3082.8(65) s. Comparisons between this superallowed ft value and the world-average-corrected Ft¯ value, as well as the nonanalog Fermi branching ratios determined in this work, provide guidance for theoretical models of the isospin-symmetry-breaking corrections in this mass region.

  20. Energy distribution measurement of narrow-band ultrashort x-ray beams via K-edge filters subtraction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cardarelli, Paolo; Di Domenico, Giovanni; Marziani, Michele

    2012-10-01

    The characterization of novel x-ray sources includes the measurement of the photon flux and the energy distribution of the produced beam. The aim of BEATS2 experiment at the SPARC-LAB facility of the INFN National Laboratories of Frascati (Rome, Italy) is to investigate possible medical applications of an x-ray source based on Thomson relativistic back-scattering. This source is expected to produce a pulsed quasi-monochromatic x-ray beam with an instantaneous flux of 10{sup 20} ph/s in pulses 10 ps long and with an average energy of about 20 keV. A direct measurement of energy distribution of this beam is very difficult withmore » traditional detectors because of the extremely high photon flux. In this paper, we present a method for the evaluation of the energy distribution of quasi-monochromatic x-ray beams based on beam filtration with K-edge absorbing foils in the energy range of interest (16-22 keV). The technique was tested measuring the energy distribution of an x-ray beam having a spectrum similar to the expected one (SPARC-LAB Thomson source) by using a tungsten anode x-ray tube properly filtered and powered. The energy distribution obtained has been compared with the one measured with a HPGe detector showing very good agreement.« less

  1. E2/M1 mixing ratios in transitions from the gamma vibrational bands to the ground state rotational bands of 102, 104, 106, 108Mo, 108, 110, 112Ru, and 112, 114, 116Pd

    NASA Astrophysics Data System (ADS)

    Eldridge, J. M.; Fenker, B.; Hamilton, J. H.; Goodin, C.; Zachary, C. J.; Wang, E.; Ramayya, A. V.; Daniel, A. V.; Ter-Akopian, G. M.; Oganessian, Yu. Ts.; Luo, Y. X.; Rasmussen, J. O.; Zhu, S. J.

    2018-02-01

    E2/ M1 mixing ratios have been measured for transitions from states in the γ vibrational bands ( I+_{γ}) to states in the ground state bands (I+ or [I-1]+) of the neutron rich, even-even, deformed isotopes, 102, 104, 106, 108Mo, 108, 110, 112Ru, and 112, 114, 116Pd, including from states as high as 9+_{γ}. These measurements were done using the GAMMASPHERE detector array, which, at the time of the experiment, had 101 working HPGe detectors, arranged at 64 different angles. A 62 μCi source of 252Cf was placed inside GAMMASPHERE yielding 5.7× 10^{11} γ-γ-γ and higher coincidence events. The angular correlations between the transitions from the γ-bands to the ground bands, and the pure E2 transitions within the ground band were then measured. These angular correlations yielded the mixing ratios, demonstrating that these transitions are pure or nearly pure E2, in agreement with theory. In order to correct for possible attenuation due to the lifetime of the intermediate state in these correlations, the g-factors of the intermediate states needed to be known. Therefore, the g-factors of the 2+ states in the ground state band have been measured.

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gurgi, L. A.; Regan, P. H.; Söderström, P. -A.

    In-flight fission of a 345 MeV per nucleon 238U primary beam on a 2 mm thick 9Be target has been used to produce and study the decays of a range of neutron-rich nuclei centred around the doubly mid-shell nucleus 170Dy at the RIBF Facility, RIKEN, Japan. The produced secondary fragments of interest were identified event-by-event using the BigRIPS separator. The fragments were implanted into the WAS3ABI position sensitive silicon active stopper which allowed pixelated correlations between implants and their subsequent β-decay. Discrete γ-ray transitions emitted following decays from either metastable states or excited states populated following beta decay were identifiedmore » using the 84 coaxial high-purity germanium (HPGe) detectors of the EURICA spectrometer, which was complemented by 18 additional cerium-doped lanthanum bromide (LaBr3) fast-timing scintillation detectors from the FATIMA collaboration. This paper presents the internal decay of a metastable isomeric excited state in the odd-odd nucleus 168Tb, which corresponds to a single proton-neutron hole configuration in the valence maximum nucleus 170Dy. These data represent the first information on excited states in this nucleus, which is the most neutron-rich odd-odd isotope of terbium (Z=65) studied to date. Nilsson configurations associated with an axially symmetric, prolate-deformed nucleus are proposed for the 168Tb ground state the observed isomeric state by comparison with Blocked BCS-Nilsson calculations.« less

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gurgi, L. A.; Regan, P. H.; Söderström, P. -A.

    In-flight fission of a 345 MeV per nucleon 238U primary beam on a 2 mm thick 9Be target has been used to produce and study the decays of a range of neutron-rich nuclei centred around the doubly mid-shell nucleus 170Dy at the RIBF Facility, RIKEN, Japan. The produced secondary fragments of interest were identified event-by-event using the BigRIPS separator. The fragments were implanted into the WAS3ABI position sensitive silicon active stopper which allowed pixelated correlations between implants and their subsequent β-decay. Discrete γ-ray transitions emitted following decays from either metastable states or excited states populated following beta decay were identifiedmore » using the 84 coaxial high-purity germanium (HPGe) detectors of the EURICA spectrometer, which was complemented by 18 additional cerium-doped lanthanum bromide (LaBr 3) fast-timing scintillation detectors from the FATIMA collaboration. This paper presents the internal decay of a metastable isomeric excited state in the odd-odd nucleus 168Tb, which corresponds to a single proton-neutron hole configuration in the valence maximum nucleus 170Dy. These data represent the first information on excited states in this nucleus, which is the most neutron-rich odd-odd isotope of terbium (Z = 65) studied to date. Here, Nilsson configurations associated with an axially symmetric, prolate-deformed nucleus are proposed for the 168Tb ground state the observed isomeric state by comparison with Blocked BCS-Nilsson calculations.« less

  4. An assessment of absorbed dose and radiation hazard index from soil around repository facility at Bukit Kledang, Perak, Malaysia

    NASA Astrophysics Data System (ADS)

    Adziz, M. I. Abdul; Khoo, K. S.

    2018-01-01

    The process of natural decay of radionuclides that emit gamma rays can infect humans and other living things. In this study, soil samples were taken at various locations which have been identified around the Long Term Storage Facility (LTSF) in Bukit Kledang, Perak. In addition, the respective dose rates in the sampling sites were measured at 5cm and 1m above the ground using a survey meter with Geiger Muller (GM) detector. Soil samples were taken using a hand Auger and then brought back to the laboratory for sample prepreparation process. The measuring of radioactivity concentration in soil samples were carried out using gamma spectrometer counting system equipped with HPGe detector. The obtained results show, the radioactivity concentration ranged from 11.98 - 29.93 Bq/kg for Radium-226 (226Ra), 20.97 - 41.45 Bq/kg for Thorium-232 (232Th) and 5.73 - 59.41 Bq/kg for Potassium-40 (40K), with mean values of 20.83 ± 5.88 Bq/kg, 32.87 ± 5.88 Bq/kg and 21.50 ± 2.79 Bq/kg, respectively. To assess the radiological hazards of natural radioactivity, radium equivalent activity (Raeq), the rate of absorption dose (D), the annual effective dose and external hazard index (Hex) was calculated and compared to the world average values.

  5. X-ray Measurements of a Thermo Scientific P385 DD Neutron Generator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    E.H. Seabury; D.L. Chichester; A.J. Caffrey

    2001-08-01

    Idaho National Laboratory is experimenting with electrical neutron generators, as potential replacements for californium-252 radioisotopic neutron sources in its PINS prompt gamma-ray neutron activation analysis (PGNAA) system for the identification of military chemical warfare agents and explosives. In addition to neutron output, we have recently measured the x-ray output of the Thermo Scientific P385 deuterium-deuterium neutron generator. X-rays are a normal byproduct from a neutron generator and depending on their intensity and energy they can interfere with gamma rays from the object under test, increase gamma-spectrometer dead time, and reduce PGNAA system throughput. The P385 x-ray energy spectrum was measuredmore » with a high-purity germanium (HPGe) detector, and a broad peak is evident at about 70 keV. To identify the source of the x-rays within the neutron generator assembly, it was scanned by collimated scintillation detectors along its long axis. At the strongest x-ray emission points, the generator also was rotated 60° between measurements. The scans show the primary source of x-ray emission from the P385 neutron generator is an area 60 mm from the neutron production target, in the vicinity of the ion source. Rotation of the neutron generator did not significantly alter the x-ray count rate, and the x-ray emission appears to be axially symmetric within the neutron generator.« less

  6. Development of a Monte Carlo Simulation for APD-Based PET Detectors Using a Continuous Scintillating Crystal

    NASA Astrophysics Data System (ADS)

    Clowes, P.; Mccallum, S.; Welch, A.

    2006-10-01

    We are currently developing a multilayer avalanche photodiode (APD)-based detector for use in positron emission tomography (PET), which utilizes thin continuous crystals. In this paper, we developed a Monte Carlo-based simulation to aid in the design of such detectors. We measured the performance of a detector comprising a single thin continuous crystal (3.1 mm times 9.5 mm times 9.5 mm) of lutetium yttrium ortho-silicate (LYSO) and an APD array (4times4) elements; each element 1.6 mm2 and on a 2.3 mm pitch. We showed that a spatial resolution of better than 2.12 mm is achievable throughout the crystal provided that we adopt a Statistics Based Positioning (SBP) Algorithm. We then used Monte Carlo simulation to model the behavior of the detector. The accuracy of the Monte Carlo simulation was verified by comparing measured and simulated parent datasets (PDS) for the SBP algorithm. These datasets consisted of data for point sources at 49 positions uniformly distributed over the detector area. We also calculated the noise in the detector circuit and verified this value by measurement. The noise value was included in the simulation. We show that the performance of the simulation closely matches the measured performance. The simulations were extended to investigate the effect of different noise levels on positioning accuracy. This paper showed that if modest improvements could be made in the circuit noise then positioning accuracy would be greatly improved. In summary, we have developed a model that can be used to simulate the performance of a variety of APD-based continuous crystal PET detectors

  7. SU-E-T-543: Measurement of Neutron Activation From Different High Energy Varian Linear Accelerators

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thatcher, T; Madsen, S; Sudowe, R

    2015-06-15

    Purpose: Linear accelerators producing photons above 10 MeV may induce photonuclear reactions in high Z components of the accelerator. These liberated neutrons can then activate the structural components of the accelerator and other materials in the beam path through neutron capture reactions. The induced activity within the accelerator may contribute to additional dose to both patients and personnel. This project seeks to determine the total activity and activity per activated isotope following irradiation in different Varian accelerators at energies above 10 MeV. Methods: A Varian 21IX accelerator was used to irradiate a 30 cm × 30 cm × 20 cmmore » solid water phantom with 15 MV x-rays. The phantom was placed at an SSD of 100 cm and at the center of a 20 cm × 20 cm field. Activation induced gamma spectra were acquired over a 5 minute interval after 1 and 15 minutes from completion of the irradiation. All measurements were made using a CANBERRA Falcon 5000 Portable HPGe detector. The majority of measurements were made in scattering geometry with the detector situated at 90° to the incident beam, 30 cm from the side of the phantom and approximately 10 cm from the top. A 5 minute background count was acquired and automatically subtracted from all subsequent measurements. Photon spectra were acquired for both open and MLC fields. Results: Based on spectral signatures, nuclides have been identified and their activities calculated for both open and MLC fields. Preliminary analyses suggest that activities from the activation products in the microcurie range. Conclusion: Activation isotopes have been identified and their relative activities determined. These activities are only gross estimates since efficiencies have not been determined for this source-detector geometry. Current efforts are focused on accurate determination of detector efficiencies using Monte Carlo calculations.« less

  8. DHS Internship Paper

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dreyer, J

    2007-09-18

    During my internship at Lawrence Livermore National Laboratory I worked with microcalorimeter gamma-ray and fast-neutron detectors based on superconducting Transition Edge Sensors (TESs). These instruments are being developed for fundamental science and nuclear non-proliferation applications because of their extremely high energy resolution; however, this comes at the expense of a small pixel size and slow decay times. The small pixel sizes are being addressed by developing detector arrays while the low count rate is being addressed by developing Digital Signal Processors (DSPs) that allow higher throughput than traditional pulse processing algorithms. Traditionally, low-temperature microcalorimeter pulses have been processed off-line withmore » optimum filtering routines based on the measured spectral characteristics of the signal and the noise. These optimum filters rely on the spectral content of the signal being identical for all events, and therefore require capturing the entire pulse signal without pile-up. In contrast, the DSP algorithm being developed is based on differences in signal levels before and after a trigger event, and therefore does not require the waveform to fully decay, or even the signal level to be close to the base line. The readout system allows for real time data acquisition and analysis at count rates exceeding 100 Hz for pulses with several {approx}ms decay times with minimal loss of energy resolution. Originally developed for gamma-ray analysis with HPGe detectors we have modified the hardware and firmware of the system to accommodate the slower TES signals and optimized the parameters of the filtering algorithm to maximize either resolution or throughput. The following presents an overview of the digital signal processing hardware and discusses the results of characterization measurements made to determine the systems performance.« less

  9. The Application of Neutron Transport Green's Functions to Threat Scenario Simulation

    NASA Astrophysics Data System (ADS)

    Thoreson, Gregory G.; Schneider, Erich A.; Armstrong, Hirotatsu; van der Hoeven, Christopher A.

    2015-02-01

    Radiation detectors provide deterrence and defense against nuclear smuggling attempts by scanning vehicles, ships, and pedestrians for radioactive material. Understanding detector performance is crucial to developing novel technologies, architectures, and alarm algorithms. Detection can be modeled through radiation transport simulations; however, modeling a spanning set of threat scenarios over the full transport phase-space is computationally challenging. Previous research has demonstrated Green's functions can simulate photon detector signals by decomposing the scenario space into independently simulated submodels. This paper presents decomposition methods for neutron and time-dependent transport. As a result, neutron detector signals produced from full forward transport simulations can be efficiently reconstructed by sequential application of submodel response functions.

  10. Software Geometry in Simulations

    NASA Astrophysics Data System (ADS)

    Alion, Tyler; Viren, Brett; Junk, Tom

    2015-04-01

    The Long Baseline Neutrino Experiment (LBNE) involves many detectors. The experiment's near detector (ND) facility, may ultimately involve several detectors. The far detector (FD) will be significantly larger than any other Liquid Argon (LAr) detector yet constructed; many prototype detectors are being constructed and studied to motivate a plethora of proposed FD designs. Whether it be a constructed prototype or a proposed ND/FD design, every design must be simulated and analyzed. This presents a considerable challenge to LBNE software experts; each detector geometry must be described to the simulation software in an efficient way which allows for multiple authors to easily collaborate. Furthermore, different geometry versions must be tracked throughout their use. We present a framework called General Geometry Description (GGD), written and developed by LBNE software collaborators for managing software to generate geometries. Though GGD is flexible enough to be used by any experiment working with detectors, we present it's first use in generating Geometry Description Markup Language (GDML) files to interface with LArSoft, a framework of detector simulations, event reconstruction, and data analyses written for all LAr technology users at Fermilab. Brett is the other of the framework discussed here, the General Geometry Description (GGD).

  11. Simulation and experimental measurement of radon activity using a multichannel silicon-based radiation detector.

    PubMed

    Ozdemir, F B; Selcuk, A B; Ozkorucuklu, S; Alpat, A B; Ozdemir, T; Ӧzek, N

    2018-05-01

    In this study, high-precision radiation detector (HIPRAD), a new-generation semiconductor microstrip detector, was used for detecting radon (Rn-222) activity. The aim of this study was to detect radon (Rn-222) activity experimentally by measuring the energy of particles in this detector. Count-ADC channel, eta-charge, and dose-response values were experimentally obtained using HIPRAD. The radon simulation in the radiation detector was theoretically performed using the Geant4 software package. The obtained radioactive decay, energy generation, energy values, and efficiency values of the simulation were plotted using the root program. The new-generation radiation detector proved to have 95% reliability according to the obtained dose-response graphs. The experimental and simulation results were found to be compatible with each other and with the radon decays and literature studies. Copyright © 2018 Elsevier Ltd. All rights reserved.

  12. Optimization of 6LiF:ZnS(Ag) scintillator light yield using GEANT4

    NASA Astrophysics Data System (ADS)

    Yehuda-Zada, Y.; Pritchard, K.; Ziegler, J. B.; Cooksey, C.; Siebein, K.; Jackson, M.; Hurlbut, C.; Kadmon, Y.; Cohen, Y.; Ibberson, R. M.; Majkrzak, C. F.; Maliszewskyj, N. C.; Orion, I.; Osovizky, A.

    2018-06-01

    A new cold neutron detector has been developed at the NIST Center for Neutron Research (NCNR) for the CANDoR (Chromatic Analysis Neutron Diffractometer or Reflectometer) project. Geometric and performance constraints dictate that this detector be exceptionally thin (∼ 2 mm). For this reason, the design of the detector consists of a 6LiF:ZnS(Ag) scintillator with embedded wavelength shifting (WLS) fibers. We used the GEANT4 package to simulate neutron capture and light transport in the detector to optimize the composition and arrangement of materials to satisfy the competing requirements of high neutron capture probability and light production and transport. In the process, we have developed a method for predicting light collection and total neutron detection efficiency for different detector configurations. The simulation was performed by adjusting crucial parameters such as the scintillator stoichiometry, light yield, component grain size, WLS fiber geometry, and reflectors at the outside edges of the scintillator volume. Three different detector configurations were fabricated and their test results were correlated with the simulations. Through this correlation we have managed to find a common photon threshold for the different detector configurations which was then used to simulate and predict the efficiencies for many other detector configurations. New detectors that have been fabricated based on simulation results yielding the desired sensitivity of 90% for 3.27 meV (5 Å) cold neutrons. The simulation has proven to be a useful tool by dramatically reducing the development period and the required number of detector prototypes. It can be used to test new designs with different thicknesses and different target neutron energies.

  13. Computational steering of GEM based detector simulations

    NASA Astrophysics Data System (ADS)

    Sheharyar, Ali; Bouhali, Othmane

    2017-10-01

    Gas based detector R&D relies heavily on full simulation of detectors and their optimization before final prototypes can be built and tested. These simulations in particular those with complex scenarios such as those involving high detector voltages or gas with larger gains are computationally intensive may take several days or weeks to complete. These long-running simulations usually run on the high-performance computers in batch mode. If the results lead to unexpected behavior, then the simulation might be rerun with different parameters. However, the simulations (or jobs) may have to wait in a queue until they get a chance to run again because the supercomputer is a shared resource that maintains a queue of other user programs as well and executes them as time and priorities permit. It may result in inefficient resource utilization and increase in the turnaround time for the scientific experiment. To overcome this issue, the monitoring of the behavior of a simulation, while it is running (or live), is essential. In this work, we employ the computational steering technique by coupling the detector simulations with a visualization package named VisIt to enable the exploration of the live data as it is produced by the simulation.

  14. Monte Carlo simulation of a NaI(Tl) detector for in situ radioactivity measurements in the marine environment.

    PubMed

    Zhang, Yingying; Li, Changkai; Liu, Dongyan; Zhang, Ying; Liu, Yan

    2015-04-01

    To develop in situ NaI(Tl) detector for radioactivity measurement in the marine environment, the Monte Carlo N-Particle (MCNP) Transport Code was utilized to simulate the measurement of NaI(Tl) detector immersed in seawater, taking into account the material and geometry of the detector, and the interactions between the photons with the atoms of the seawater and the detector. The simulation results of the marine detection efficiency and distance were deduced and analyzed. In order to test their reliability, the field measurement was made at open sea and the experimental value of the marine detection efficiency was deduced and seems to be in good agreement with the simulated one. The minimum detectable activity for (137)Cs in the seawater of NaI(Tl) detector developed was determined mathematically at last. The simulation method and results in the paper can be used for the better design and quantitative calculation of in situ NaI(Tl) detector for radioactivity measurement in the marine environment, and also for some applications such as the installation on the marine monitoring platform and the quantitative analysis of radionuclides. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. CatSim: a new computer assisted tomography simulation environment

    NASA Astrophysics Data System (ADS)

    De Man, Bruno; Basu, Samit; Chandra, Naveen; Dunham, Bruce; Edic, Peter; Iatrou, Maria; McOlash, Scott; Sainath, Paavana; Shaughnessy, Charlie; Tower, Brendon; Williams, Eugene

    2007-03-01

    We present a new simulation environment for X-ray computed tomography, called CatSim. CatSim provides a research platform for GE researchers and collaborators to explore new reconstruction algorithms, CT architectures, and X-ray source or detector technologies. The main requirements for this simulator are accurate physics modeling, low computation times, and geometrical flexibility. CatSim allows simulating complex analytic phantoms, such as the FORBILD phantoms, including boxes, ellipsoids, elliptical cylinders, cones, and cut planes. CatSim incorporates polychromaticity, realistic quantum and electronic noise models, finite focal spot size and shape, finite detector cell size, detector cross-talk, detector lag or afterglow, bowtie filtration, finite detector efficiency, non-linear partial volume, scatter (variance-reduced Monte Carlo), and absorbed dose. We present an overview of CatSim along with a number of validation experiments.

  16. The Monte Carlo simulation of the Borexino detector

    NASA Astrophysics Data System (ADS)

    Agostini, M.; Altenmüller, K.; Appel, S.; Atroshchenko, V.; Bagdasarian, Z.; Basilico, D.; Bellini, G.; Benziger, J.; Bick, D.; Bonfini, G.; Borodikhina, L.; Bravo, D.; Caccianiga, B.; Calaprice, F.; Caminata, A.; Canepa, M.; Caprioli, S.; Carlini, M.; Cavalcante, P.; Chepurnov, A.; Choi, K.; D'Angelo, D.; Davini, S.; Derbin, A.; Ding, X. F.; Di Noto, L.; Drachnev, I.; Fomenko, K.; Formozov, A.; Franco, D.; Froborg, F.; Gabriele, F.; Galbiati, C.; Ghiano, C.; Giammarchi, M.; Goeger-Neff, M.; Goretti, A.; Gromov, M.; Hagner, C.; Houdy, T.; Hungerford, E.; Ianni, Aldo; Ianni, Andrea; Jany, A.; Jeschke, D.; Kobychev, V.; Korablev, D.; Korga, G.; Kryn, D.; Laubenstein, M.; Litvinovich, E.; Lombardi, F.; Lombardi, P.; Ludhova, L.; Lukyanchenko, G.; Machulin, I.; Magnozzi, M.; Manuzio, G.; Marcocci, S.; Martyn, J.; Meroni, E.; Meyer, M.; Miramonti, L.; Misiaszek, M.; Muratova, V.; Neumair, B.; Oberauer, L.; Opitz, B.; Ortica, F.; Pallavicini, M.; Papp, L.; Pocar, A.; Ranucci, G.; Razeto, A.; Re, A.; Romani, A.; Roncin, R.; Rossi, N.; Schönert, S.; Semenov, D.; Shakina, P.; Skorokhvatov, M.; Smirnov, O.; Sotnikov, A.; Stokes, L. F. F.; Suvorov, Y.; Tartaglia, R.; Testera, G.; Thurn, J.; Toropova, M.; Unzhakov, E.; Vishneva, A.; Vogelaar, R. B.; von Feilitzsch, F.; Wang, H.; Weinz, S.; Wojcik, M.; Wurm, M.; Yokley, Z.; Zaimidoroga, O.; Zavatarelli, S.; Zuber, K.; Zuzel, G.

    2018-01-01

    We describe the Monte Carlo (MC) simulation of the Borexino detector and the agreement of its output with data. The Borexino MC "ab initio" simulates the energy loss of particles in all detector components and generates the resulting scintillation photons and their propagation within the liquid scintillator volume. The simulation accounts for absorption, reemission, and scattering of the optical photons and tracks them until they either are absorbed or reach the photocathode of one of the photomultiplier tubes. Photon detection is followed by a comprehensive simulation of the readout electronics response. The MC is tuned using data collected with radioactive calibration sources deployed inside and around the scintillator volume. The simulation reproduces the energy response of the detector, its uniformity within the fiducial scintillator volume relevant to neutrino physics, and the time distribution of detected photons to better than 1% between 100 keV and several MeV. The techniques developed to simulate the Borexino detector and their level of refinement are of possible interest to the neutrino community, especially for current and future large-volume liquid scintillator experiments such as Kamland-Zen, SNO+, and Juno.

  17. Numerical integration of detector response functions via Monte Carlo simulations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kelly, Keegan John; O'Donnell, John M.; Gomez, Jaime A.

    Calculations of detector response functions are complicated because they include the intricacies of signal creation from the detector itself as well as a complex interplay between the detector, the particle-emitting target, and the entire experimental environment. As such, these functions are typically only accessible through time-consuming Monte Carlo simulations. Furthermore, the output of thousands of Monte Carlo simulations can be necessary in order to extract a physics result from a single experiment. Here we describe a method to obtain a full description of the detector response function using Monte Carlo simulations. We also show that a response function calculated inmore » this way can be used to create Monte Carlo simulation output spectra a factor of ~1000× faster than running a new Monte Carlo simulation. A detailed discussion of the proper treatment of uncertainties when using this and other similar methods is provided as well. Here, this method is demonstrated and tested using simulated data from the Chi-Nu experiment, which measures prompt fission neutron spectra at the Los Alamos Neutron Science Center.« less

  18. Numerical integration of detector response functions via Monte Carlo simulations

    NASA Astrophysics Data System (ADS)

    Kelly, K. J.; O'Donnell, J. M.; Gomez, J. A.; Taddeucci, T. N.; Devlin, M.; Haight, R. C.; White, M. C.; Mosby, S. M.; Neudecker, D.; Buckner, M. Q.; Wu, C. Y.; Lee, H. Y.

    2017-09-01

    Calculations of detector response functions are complicated because they include the intricacies of signal creation from the detector itself as well as a complex interplay between the detector, the particle-emitting target, and the entire experimental environment. As such, these functions are typically only accessible through time-consuming Monte Carlo simulations. Furthermore, the output of thousands of Monte Carlo simulations can be necessary in order to extract a physics result from a single experiment. Here we describe a method to obtain a full description of the detector response function using Monte Carlo simulations. We also show that a response function calculated in this way can be used to create Monte Carlo simulation output spectra a factor of ∼ 1000 × faster than running a new Monte Carlo simulation. A detailed discussion of the proper treatment of uncertainties when using this and other similar methods is provided as well. This method is demonstrated and tested using simulated data from the Chi-Nu experiment, which measures prompt fission neutron spectra at the Los Alamos Neutron Science Center.

  19. Refined lateral energy correction functions for the KASCADE-Grande experiment based on Geant4 simulations

    NASA Astrophysics Data System (ADS)

    Gherghel-Lascu, A.; Apel, W. D.; Arteaga-Velázquez, J. C.; Bekk, K.; Bertaina, M.; Blümer, J.; Bozdog, H.; Brancus, I. M.; Cantoni, E.; Chiavassa, A.; Cossavella, F.; Daumiller, K.; de Souza, V.; Di Pierro, F.; Doll, P.; Engel, R.; Engler, J.; Fuchs, B.; Fuhrmann, D.; Gils, H. J.; Glasstetter, R.; Grupen, C.; Haungs, A.; Heck, D.; Hörandel, J. R.; Huber, D.; Huege, T.; Kampert, K.-H.; Kang, D.; Klages, H. O.; Link, K.; Łuczak, P.; Mathes, H. J.; Mayer, H. J.; Milke, J.; Mitrica, B.; Morello, C.; Oehlschläger, J.; Ostapchenko, S.; Palmieri, N.; Petcu, M.; Pierog, T.; Rebel, H.; Roth, M.; Schieler, H.; Schoo, S.; Schröder, F. G.; Sima, O.; Toma, G.; Trinchero, G. C.; Ulrich, H.; Weindl, A.; Wochele, J.; Zabierowski, J.

    2015-02-01

    In previous studies of KASCADE-Grande data, a Monte Carlo simulation code based on the GEANT3 program has been developed to describe the energy deposited by EAS particles in the detector stations. In an attempt to decrease the simulation time and ensure compatibility with the geometry description in standard KASCADE-Grande analysis software, several structural elements have been neglected in the implementation of the Grande station geometry. To improve the agreement between experimental and simulated data, a more accurate simulation of the response of the KASCADE-Grande detector is necessary. A new simulation code has been developed based on the GEANT4 program, including a realistic geometry of the detector station with structural elements that have not been considered in previous studies. The new code is used to study the influence of a realistic detector geometry on the energy deposited in the Grande detector stations by particles from EAS events simulated by CORSIKA. Lateral Energy Correction Functions are determined and compared with previous results based on GEANT3.

  20. Numerical integration of detector response functions via Monte Carlo simulations

    DOE PAGES

    Kelly, Keegan John; O'Donnell, John M.; Gomez, Jaime A.; ...

    2017-06-13

    Calculations of detector response functions are complicated because they include the intricacies of signal creation from the detector itself as well as a complex interplay between the detector, the particle-emitting target, and the entire experimental environment. As such, these functions are typically only accessible through time-consuming Monte Carlo simulations. Furthermore, the output of thousands of Monte Carlo simulations can be necessary in order to extract a physics result from a single experiment. Here we describe a method to obtain a full description of the detector response function using Monte Carlo simulations. We also show that a response function calculated inmore » this way can be used to create Monte Carlo simulation output spectra a factor of ~1000× faster than running a new Monte Carlo simulation. A detailed discussion of the proper treatment of uncertainties when using this and other similar methods is provided as well. Here, this method is demonstrated and tested using simulated data from the Chi-Nu experiment, which measures prompt fission neutron spectra at the Los Alamos Neutron Science Center.« less

  1. The ATLAS Simulation Infrastructure

    DOE PAGES

    Aad, G.; Abbott, B.; Abdallah, J.; ...

    2010-09-25

    The simulation software for the ATLAS Experiment at the Large Hadron Collider is being used for large-scale production of events on the LHC Computing Grid. This simulation requires many components, from the generators that simulate particle collisions, through packages simulating the response of the various detectors and triggers. All of these components come together under the ATLAS simulation infrastructure. In this paper, that infrastructure is discussed, including that supporting the detector description, interfacing the event generation, and combining the GEANT4 simulation of the response of the individual detectors. Also described are the tools allowing the software validation, performance testing, andmore » the validation of the simulated output against known physics processes.« less

  2. Monte Carlo simulation of simultaneous radiation detection in the hybrid tomography system ClearPET-XPAD3/CT

    NASA Astrophysics Data System (ADS)

    Dávila, H. Olaya; Sevilla, A. C.; Castro, H. F.; Martínez, S. A.

    2016-07-01

    Using the Geant4 based simulation framework SciFW1, a detailed simulation was performed for a detector array in the hybrid tomography prototype for small animals called ClearPET / XPAD, which was built in the Centre de Physique des Particules de Marseille. The detector system consists of an array of phoswich scintillation detectors: LSO (Lutetium Oxy-ortosilicate doped with cerium Lu2SiO5:Ce) and LuYAP (Lutetium Ortoaluminate of Yttrium doped with cerium Lu0.7Y0.3AlO3:Ce) for Positron Emission Tomography (PET) and hybrid pixel detector XPAD for Computed Tomography (CT). Simultaneous acquisition of deposited energy and the corresponding time - position for each recorded event were analyzed, independently, for both detectors. interference between detection modules for PET and CT. Information about amount of radiation reaching each phoswich crystal and XPAD detector using a phantom in order to study the effectiveness by radiation attenuation and influence the positioning of the radioactive source 22Na was obtained. The simulation proposed will improve distribution of detectors rings and interference values will be taken into account in the new versions of detectors.

  3. Monte Carlo Simulation of a Segmented Detector for Low-Energy Electron Antineutrinos

    NASA Astrophysics Data System (ADS)

    Qomi, H. Akhtari; Safari, M. J.; Davani, F. Abbasi

    2017-11-01

    Detection of low-energy electron antineutrinos is of importance for several purposes, such as ex-vessel reactor monitoring, neutrino oscillation studies, etc. The inverse beta decay (IBD) is the interaction that is responsible for detection mechanism in (organic) plastic scintillation detectors. Here, a detailed study will be presented dealing with the radiation and optical transport simulation of a typical segmented antineutrino detector withMonte Carlo method using MCNPX and FLUKA codes. This study shows different aspects of the detector, benefiting from inherent capabilities of the Monte Carlo simulation codes.

  4. GRABGAM Analysis of Ultra-Low-Level HPGe Gamma Spectra

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Winn, W.G.

    The GRABGAM code has been used successfully for ultra-low level HPGe gamma spectrometry analysis since its development in 1985 at Savannah River Technology Center (SRTC). Although numerous gamma analysis codes existed at that time, reviews of institutional and commercial codes indicated that none addressed all features that were desired by SRTC. Furthermore, it was recognized that development of an in-house code would better facilitate future evolution of the code to address SRTC needs based on experience with low-level spectra. GRABGAM derives its name from Gamma Ray Analysis BASIC Generated At MCA/PC.

  5. Design and optimization of a novel 3D detector: The 3D-open-shell-electrode detector

    NASA Astrophysics Data System (ADS)

    Liu, Manwen; Tan, Jian; Li, Zheng

    2018-04-01

    A new type of three-dimensional (3D) detector, namely 3D-Open-Shell-Electrode Detector (3DOSED), is proposed in this study. In a 3DOSED, the trench electrode can be etched all the way through the detector thickness, totally eliminating the low electric field region existed in the conventional 3D-Trench-Electrode detector. Full 3D technology computer-aided design (TCAD) simulations have been done on this novel silicon detector structure. Through comparing of the simulation results of the detector, we can obtain the best design of the 3SOSED. In addition, simulation results show that, as compared to the conventional 3D detector, the proposed 3DOSED can improve not only detector charge collection efficiency but also its radiation hardness with regard to solving the trapping problem in the detector bulk. What is more, it has been shown that detector full depletion voltage is also slightly reduced, which can improve the utility aspects of the detector. When compared to the conventional 3D detector, we find that the proposed novel 3DOSED structure has better electric potential and electric field distributions, and better electrical properties such as detector full depletion voltage. In 3DOSED array, each pixel cell is isolated from each other by highly doped trenches, but also electrically and physically connected with each other through the remaining silicon bulk between broken electrodes.

  6. Performance simulation of a detector for 4th generation photon sources: The AGIPD

    NASA Astrophysics Data System (ADS)

    Potdevin, G.; Trunk, U.; Graafsma, H.; Agipd Consortium

    2009-08-01

    Future 4th generation photon sources, such as the European XFEL based in Hamburg, will deliver around 1012 X-ray photons in less than 100 fs with full lateral coherence. These new sources will offer unprecedented possibilities in photon science. The high peak brilliance, combined with a 5 MHz repetition rate poses very high demands for the 2D detectors. In order to provide appropriate detectors during XFEL startup, three dedicated development projects have been initiated, one of them being the Adaptive Gain Integrating Pixel Detector (AGIPD) project which is a collaborative effort between DESY, PSI, University of Bonn, and University of Hamburg. An essential part of the AGIPD project is the development of a simulation tool for the complete detection system. The simulation tool as well as preliminary simulations of the detector characteristics is presented.

  7. MCNP6 simulation of radiographs generated from megaelectron volt X-rays for characterizing a computed tomography system

    NASA Astrophysics Data System (ADS)

    Dooraghi, Alex A.; Tringe, Joseph W.

    2018-04-01

    To evaluate conventional munition, we simulated an x-ray computed tomography (CT) system for generating radiographs from nominal x-ray energies of 6 or 9 megaelectron volts (MeV). CT simulations, informed by measured data, allow for optimization of both system design and acquisition techniques necessary to enhance image quality. MCNP6 radiographic simulation tools were used to model ideal detector responses (DR) that assume either (1) a detector response proportional to photon flux (N) or (2) a detector response proportional to energy flux (E). As scatter may become significant with MeV x-ray systems, simulations were performed with and without the inclusion of object scatter. Simulations were compared against measurements of a cylindrical munition component principally composed of HMX, tungsten and aluminum encased in carbon fiber. Simulations and measurements used a 6 MeV peak energy x-ray spectrum filtered with 3.175 mm of tantalum. A detector response proportional to energy which includes object scatter agrees to within 0.6 % of the measured line integral of the linear attenuation coefficient. Exclusion of scatter increases the difference between measurement and simulation to 5 %. A detector response proportional to photon flux agrees to within 20 % when object scatter is included in the simulation and 27 % when object scatter is excluded.

  8. CAD tools for detector design

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Womersley, J.; DiGiacomo, N.; Killian, K.

    1990-04-01

    Detailed detector design has traditionally been divided between engineering optimization for structural integrity and subsequent physicist evaluation. The availability of CAD systems for engineering design enables the tasks to be integrated by providing tools for particle simulation within the CAD system. We believe this will speed up detector design and avoid problems due to the late discovery of shortcomings in the detector. This could occur because of the slowness of traditional verification techniques (such as detailed simulation with GEANT). One such new particle simulation tool is described. It is being used with the I-DEAS CAD package for SSC detector designmore » at Martin-Marietta Astronautics and is to be released through the SSC Laboratory.« less

  9. Seasonal measurement and dose assessment of natural radionuclides in sediments of Darbandikhan Lake in Kurdistan-Iraq

    NASA Astrophysics Data System (ADS)

    Omer Jafir, Adeeb; Ahmed, Ali Hassan; Saridan, Wan Muhammad

    2017-11-01

    A total of 100 sediment samples were collected from Darbandikhan Lake and its different resources (spring, stream, and lake) during the four seasons. Spectrometry analysis of HPGe detector was used for measuring the specific activity. The seasonally measured mean activity concentration of 238U, 232Th and40K for sediment samples were 11.9±1.0, 7.8±1.0 and 213.4±3.4 Bq/kg in spring; 9.2±1.1, 7.9±1.0 and 205.8±3.0 Bq/kg in summer; 12.7±1.5, 8.2±1.0 and 188.1±3.1 Bq/kg in autumn; 11.9±1.6, 9.1±1.0 and 218.7±3.0 Bq/kg in winter, respectively. The obtained activity concentrations of 238U, 232Th and 40K are all below the recommended values suggested by UNSCEAR (2000) for sediment 35, 30 and 400 Bq/kg, respectively. The ordinary kriging method was used to draw the contour maps using the surfer digital program. RESRAD-BUILD simulation code was used to determine the indoor dose, annual dose rate and cancer risks received and exposed to individuals in the dwellings, which show an increase over a period of 50 years. Two scenario descriptions of changing wall thickness and room dimension were, studied and they shows that the indoor dose and cancer risks increase with wall thicknesses until 50 cm and over a period of 50 years, as well as the increase of room size increases the internal dose and cancer risks inside the buildings. From the analyzed results it was concluded that the sediments in the Darbandikhan Lake has no risks when used in building construction.

  10. A Fast Monte Carlo Simulation for the International Linear Collider Detector

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Furse, D.; /Georgia Tech

    2005-12-15

    The following paper contains details concerning the motivation for, implementation and performance of a Java-based fast Monte Carlo simulation for a detector designed to be used in the International Linear Collider. This simulation, presently included in the SLAC ILC group's org.lcsim package, reads in standard model or SUSY events in STDHEP file format, stochastically simulates the blurring in physics measurements caused by intrinsic detector error, and writes out an LCIO format file containing a set of final particles statistically similar to those that would have found by a full Monte Carlo simulation. In addition to the reconstructed particles themselves, descriptionsmore » of the calorimeter hit clusters and tracks that these particles would have produced are also included in the LCIO output. These output files can then be put through various analysis codes in order to characterize the effectiveness of a hypothetical detector at extracting relevant physical information about an event. Such a tool is extremely useful in preliminary detector research and development, as full simulations are extremely cumbersome and taxing on processor resources; a fast, efficient Monte Carlo can facilitate and even make possible detector physics studies that would be very impractical with the full simulation by sacrificing what is in many cases inappropriate attention to detail for valuable gains in time required for results.« less

  11. Upgrades for the CMS simulation

    DOE PAGES

    Lange, D. J.; Hildreth, M.; Ivantchenko, V. N.; ...

    2015-05-22

    Over the past several years, the CMS experiment has made significant changes to its detector simulation application. The geometry has been generalized to include modifications being made to the CMS detector for 2015 operations, as well as model improvements to the simulation geometry of the current CMS detector and the implementation of a number of approved and possible future detector configurations. These include both completely new tracker and calorimetry systems. We have completed the transition to Geant4 version 10, we have made significant progress in reducing the CPU resources required to run our Geant4 simulation. These have been achieved throughmore » both technical improvements and through numerical techniques. Substantial speed improvements have been achieved without changing the physics validation benchmarks that the experiment uses to validate our simulation application for use in production. As a result, we will discuss the methods that we implemented and the corresponding demonstrated performance improvements deployed for our 2015 simulation application.« less

  12. Impact of detector simulation in particle physics collider experiments

    NASA Astrophysics Data System (ADS)

    Daniel Elvira, V.

    2017-06-01

    Through the last three decades, accurate simulation of the interactions of particles with matter and modeling of detector geometries has proven to be of critical importance to the success of the international high-energy physics (HEP) experimental programs. For example, the detailed detector modeling and accurate physics of the Geant4-based simulation software of the CMS and ATLAS particle physics experiments at the European Center of Nuclear Research (CERN) Large Hadron Collider (LHC) was a determinant factor for these collaborations to deliver physics results of outstanding quality faster than any hadron collider experiment ever before. This review article highlights the impact of detector simulation on particle physics collider experiments. It presents numerous examples of the use of simulation, from detector design and optimization, through software and computing development and testing, to cases where the use of simulation samples made a difference in the precision of the physics results and publication turnaround, from data-taking to submission. It also presents estimates of the cost and economic impact of simulation in the CMS experiment. Future experiments will collect orders of magnitude more data with increasingly complex detectors, taxing heavily the performance of simulation and reconstruction software. Consequently, exploring solutions to speed up simulation and reconstruction software to satisfy the growing demand of computing resources in a time of flat budgets is a matter that deserves immediate attention. The article ends with a short discussion on the potential solutions that are being considered, based on leveraging core count growth in multicore machines, using new generation coprocessors, and re-engineering HEP code for concurrency and parallel computing.

  13. Low background screening capability in the UK

    NASA Astrophysics Data System (ADS)

    Ghag, Chamkaur

    2015-08-01

    Low background rare event searches in underground laboratories seeking observation of direct dark matter interactions or neutrino-less double beta decay have the potential to profoundly advance our understanding of the physical universe. Successful results from these experiments depend critically on construction from extremely radiologically clean materials and accurate knowledge of subsequent low levels of expected background. The experiments must conduct comprehensive screening campaigns to reduce radioactivity from detector components, and these measurements also inform detailed characterisation and quantification of background sources and their impact, necessary to assign statistical significance to any potential discovery. To provide requisite sensitivity for material screening and characterisation in the UK to support our rare event search activities, we have re-developed our infrastructure to add ultra-low background capability across a range of complementary techniques that collectively allow complete radioactivity measurements. Ultra-low background HPGe and BEGe detectors have been installed at the Boulby Underground Laboratory, itself undergoing substantial facility re-furbishment, to provide high sensitivity gamma spectroscopy in particular for measuring the uranium and thorium decay series products. Dedicated low-activity mass spectrometry instrumentation has been developed at UCL for part per trillion level contaminant identification to complement underground screening with direct U and Th measurements, and meet throughput demands. Finally, radon emanation screening at UCL measures radon background inaccessible to gamma or mass spectrometry techniques. With this new capability the UK is delivering half of the radioactivity screening for the LZ dark matter search experiment.

  14. High resolution monitoring system for IRE stack releases.

    PubMed

    Deconninck, B; De Lellis, C

    2013-11-01

    The main activity of IRE (Institute for Radio-Element) is radioisotope production of bulk (99)Mo and (131)I for medical application (diagnosis and therapy). Those isotopes are chemically extracted from HEU (High Enriched Uranium) targets activated in reactors. During this process, fission products are released from the targets, including noble gases isotopes (Xe and Kr). Like any nuclear plant, IRE has release limits which are given by the Belgium authority and moreover IRE is in the process of continuously reducing the level of its releases. To achieve this mission, the need of an accurate tool is necessary and IRE has developed a specific monitoring system using a high resolution detector in order to identify and accurately estimate its gaseous releases. This system has a continuous air sampling system in the plant main stack. The sampled gases cross charcoal cartridges where they are slowed down and concentrated for higher detection efficiency. In front of those cartridges is installed an HPGe detector with a detection chain connected to a specific analysis system allowing on-line spectrum analysis. Each isotope can be separately followed without interferences, especially during the production process where high activity can be released. Due to its conception, the system also allows to measure iodine isotopes by integration on the charcoal cartridges. This device is of great help for accurately estimate IRE releases and to help for understanding specific releases and their origin in the production or maintenance process. Copyright © 2013 Elsevier Ltd. All rights reserved.

  15. Coulomb excitation of radioactive 20, 21Na

    NASA Astrophysics Data System (ADS)

    Schumaker, M. A.; Cline, D.; Hackman, G.; Pearson, C.; Svensson, C. E.; Wu, C. Y.; Andreyev, A.; Austin, R. A. E.; Ball, G. C.; Bandyopadhyay, D.; Becker, J. A.; Boston, A. J.; Boston, H. C.; Buchmann, L.; Churchman, R.; Cifarelli, F.; Cooper, R. J.; Cross, D. S.; Dashdorj, D.; Demand, G. A.; Dimmock, M. R.; Drake, T. E.; Finlay, P.; Gallant, A. T.; Garrett, P. E.; Green, K. L.; Grint, A. N.; Grinyer, G. F.; Harkness, L. J.; Hayes, A. B.; Kanungo, R.; Lisetskiy, A. F.; Leach, K. G.; Lee, G.; Maharaj, R.; Martin, J.-P.; Moisan, F.; Morton, A. C.; Mythili, S.; Nelson, L.; Newman, O.; Nolan, P. J.; Orce, J. N.; Padilla-Rodal, E.; Phillips, A. A.; Porter-Peden, M.; Ressler, J. J.; Roy, R.; Ruiz, C.; Sarazin, F.; Scraggs, D. P.; Waddington, J. C.; Wan, J. M.; Whitbeck, A.; Williams, S. J.; Wong, J.

    2009-12-01

    The low-energy structures of the radioactive nuclei 20, 21Na have been examined using Coulomb excitation at the TRIUMF-ISAC radioactive ion beam facility. Beams of ˜ 5×106 ions/s were accelerated to 1.7MeV/A and Coulomb excited in a 0.5mg/cm^2 natTi target. Two TIGRESS HPGe clover detectors perpendicular to the beam axis were used for γ -ray detection, while scattered nuclei were observed by the Si detector BAMBINO. For 21Na , Coulomb excitation from the 3/2+ ground state to the first excited 5/2+ state was observed, while for 20Na , Coulomb excitation was observed from the 2+ ground state to the first excited 3+ and 4+ states. For both beams, B ( λ L) values were determined using the 2+ rightarrow 0+ de-excitation in 48Ti as a reference. The resulting B( E2) ↓ value for 21Na is 137±9 e^2fm^4, while the resulting B( λ L) ↓ values for 20Na are 55±6 e^2fm^4 for the 3+ rightarrow 2+ , 35.7±5.7 e^2 fm^4 for the 4+ rightarrow 2+ , and 0.154±0.030 μ_ N^2 for the 4+ rightarrow 3+ transitions. This analysis significantly improves the measurement of the 21Na B( E2) value, and provides the first experimental determination of B( λ L) values for the proton dripline nucleus 20Na .-1

  16. E 2 / M 1 Mixing Ratios in Transitions From the Gamma-Vibrational-Bands to the Ground-State-Rotational-Bands of 102 , 104 , 106 , 108Mo, 108 , 110 , 112Ru, and 112 , 114 , 116Pd

    NASA Astrophysics Data System (ADS)

    Eldridge, Jonathan M.; Fenker, B.; Goodin, C.; Hamilton, J. H.; Wang, E. H.; Ramayya, A. V.; Daniel, A. V.; Ter-Akopian, G. M.; Luo, Y. X.; Rasmussen, J. O.; Oganesson, Yu. Ts.; Zhu, S. J.

    2017-09-01

    E 2 / M 1 mixing ratios have been measured for transitions from states in the γ-vibrational-bands (Iγ+) to states in the ground-state-bands (Ig+ or [I- 1 ] g +) of the neutron rich, deformed isotopes, 102 , 104 , 106 , 108Mo, 108 , 110 , 112Ru, and 112 , 114 , 116Pd, including from states as high as 9γ+. These measurements were done using the GAMMASPHERE detector array, which, at the time of the experiment, had 101 working HPGe detectors, arranged at 64 different angles. A 62 μCi source of 252Cf was placed inside GAMMASPHERE yielding 5.7 ×1011 γ - γ - γ and higher coincidence events. The angular correlation between the transitions from the γ-band to the ground band, and the pure E2 transitions within the ground band were then measured. These angular correlations yielded the mixing ratios, demonstrating that these transitions are all pure or nearly pure E2, in agreement with theory. In order to correct for possible attenuation due to the lifetime of the intermediate state in these correlations, the g-factors of the intermediate states needed to be known. Therefore, the g-factors of the 2g+ states in the ground state band have been measured. Supported by the US Department of Energy; Grant No. DE-FG0588ER40407, Contract No. DE-AC03-76SF00098.

  17. Isomer spectroscopy of neutron-rich 168Tb 103

    DOE PAGES

    Gurgi, L. A.; Regan, P. H.; Söderström, P. -A.; ...

    2016-12-29

    In-flight fission of a 345 MeV per nucleon 238U primary beam on a 2 mm thick 9Be target has been used to produce and study the decays of a range of neutron-rich nuclei centred around the doubly mid-shell nucleus 170Dy at the RIBF Facility, RIKEN, Japan. The produced secondary fragments of interest were identified event-by-event using the BigRIPS separator. The fragments were implanted into the WAS3ABI position sensitive silicon active stopper which allowed pixelated correlations between implants and their subsequent β-decay. Discrete γ-ray transitions emitted following decays from either metastable states or excited states populated following beta decay were identifiedmore » using the 84 coaxial high-purity germanium (HPGe) detectors of the EURICA spectrometer, which was complemented by 18 additional cerium-doped lanthanum bromide (LaBr 3) fast-timing scintillation detectors from the FATIMA collaboration. This paper presents the internal decay of a metastable isomeric excited state in the odd-odd nucleus 168Tb, which corresponds to a single proton-neutron hole configuration in the valence maximum nucleus 170Dy. These data represent the first information on excited states in this nucleus, which is the most neutron-rich odd-odd isotope of terbium (Z = 65) studied to date. Here, Nilsson configurations associated with an axially symmetric, prolate-deformed nucleus are proposed for the 168Tb ground state the observed isomeric state by comparison with Blocked BCS-Nilsson calculations.« less

  18. The feasibility of in vivo detection of lanthanum using a 241Am K x-ray fluorescence system.

    PubMed

    Nguyen, Joanna; Keldani, Zaid; Da Silva, Eric; Pejović-Milić, Ana; Gräfe, James L

    2017-08-21

    Lanthanum (La) is commonly used in phosphate binders in the form of lanthanum carbonate in patients with end-stage kidney disease undergoing hemodialysis treatments. With this administration, there is the potential for La storage in the body with bone being the main site of concern. However, the long-term effects of residual La in the body on bone health are not yet known. In this work, we investigate the feasibility of using a K x-ray fluorescence (K-XRF) spectroscopy system to measure bone La in vivo. A series of hydroxyapatite (HAp) bone mineral phantoms were created to represent human bone. A 1.09 GBq 241 Am source was used to excite the HAp phantoms doped with various known concentrations of La placed in a 90° geometry relative to the photon source and high-purity germanium (HPGe) detector. For a detector live time of 2000 s, the minimum detection limit was calculated to be 1.7 µg La g -1 Ca or 0.7 µg La g -1 HAp and is comparable to previously reported in vivo bone La concentrations. The technique developed in this study shows promising results and provides an alternative method to invasive biopsy sampling techniques to monitor the accumulation of bone La. To the best of our knowledge, this is the first reported work that seeks to non-invasively measure bone La via in vivo XRF.

  19. Isomer spectroscopy of neutron-rich 168Tb103

    NASA Astrophysics Data System (ADS)

    Gurgi, L. A.; Regan, P. H.; Söderström, P.-A.; Watanabe, H.; Walker, P. M.; Podolyák, Zs.; Nishimura, S.; Berry, T. A.; Doornenbal, P.; Lorusso, G.; Isobe, T.; Baba, H.; Xu, Z. Y.; Sakurai, H.; Sumikama, T.; Catford, W. N.; Bruce, A. M.; Browne, F.; Lane, G. J.; Kondev, F. G.; Odahara, A.; Wu, J.; Liu, H. L.; Xu, F. R.; Korkulu, Z.; Lee, P.; Liu, J. J.; Phong, V. H.; Yag, A.; Zhang, G. X.; Alharbi, T.; Carroll, R. J.; Chae, K. Y.; Dombradi, Zs.; Estrade, A.; Fukuda, N.; Griffin, C.; Ideguchi, E.; Inabe, N.; Kanaoka, H.; Kojouharov, I.; Kubo, T.; Kubono, S.; Kurz, N.; Kuti, I.; Lalkovski, S.; Lee, E. J.; Lee, C. S.; Lotay, G.; Moon, C.-B.; Nishizuka, I.; Nita, C. R.; Patel, Z.; Roberts, O. J.; Schaffner, H.; Shand, C. M.; Suzuki, H.; Takeda, H.; Terashima, S.; Vajta, Zs.; Yoshida, S.; Valiente-Dòbon, J. J.

    2017-11-01

    In-flight fission of a 345 MeV per nucleon 238U primary beam on a 2 mm thick 9Be target has been used to produce and study the decays of a range of neutron-rich nuclei centred around the doubly mid-shell nucleus 170Dy at the RIBF Facility, RIKEN, Japan. The produced secondary fragments of interest were identified event-by-event using the BigRIPS separator. The fragments were implanted into the WAS3ABI position sensitive silicon active stopper which allowed pixelated correlations between implants and their subsequent β-decay. Discrete γ-ray transitions emitted following decays from either metastable states or excited states populated following beta decay were identified using the 84 coaxial high-purity germanium (HPGe) detectors of the EURICA spectrometer, which was complemented by 18 additional cerium-doped lanthanum bromide (LaBr3) fast-timing scintillation detectors from the FATIMA collaboration. This paper presents the internal decay of a metastable isomeric excited state in the odd-odd nucleus 168Tb, which corresponds to a single proton-neutron hole configuration in the valence maximum nucleus 170Dy. These data represent the first information on excited states in this nucleus, which is the most neutron-rich odd-odd isotope of terbium (Z=65) studied to date. Nilsson configurations associated with an axially symmetric, prolate-deformed nucleus are proposed for the 168Tb ground state the observed isomeric state by comparison with Blocked BCS-Nilsson calculations.

  20. X-Ray Measurements Of A Thermo Scientific P385 DD Neutron Generator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wharton, C. J.; Seabury, E. H.; Chichester, D. L.

    2011-06-01

    Idaho National Laboratory is experimenting with electrical neutron generators, as potential replacements for californium-252 radioisotopic neutron sources in its PINS prompt gamma-ray neutron activation analysis (PGNAA) system for the identification of military chemical warfare agents and explosives. In addition to neutron output, we have recently measured the x-ray output of the Thermo Scientific P385 deuterium-deuterium neutron generator. X rays are a normal byproduct from neutron generators, but depending on their intensity and energy, x rays can interfere with gamma rays from the object under test, increase gamma-spectrometer dead time, and reduce PGNAA system throughput. The P385 x-ray energy spectrum wasmore » measured with a high-purity germanium (HPGe) detector, and a broad peak is evident at about 70 keV. To identify the source of the x rays within the neutron generator assembly, it was scanned by collimated scintillation detectors along its long axis. At the strongest x-ray emission points, the generator also was rotated 60 deg. between measurements. The scans show the primary source of x-ray emission from the P385 neutron generator is an area 60 mm from the neutron production target, in the vicinity of the ion source. Rotation of the neutron generator did not significantly alter the x-ray count rate, and its x-ray emission appears to be axially symmetric. A thin lead shield, 3.2 mm (1/8 inch) thick, reduced the 70-keV generator x rays to negligible levels.« less

  1. X-Ray Measurements Of A Thermo Scientific P385 DD Neutron Generator

    NASA Astrophysics Data System (ADS)

    Wharton, C. J.; Seabury, E. H.; Chichester, D. L.; Caffrey, A. J.; Simpson, J.; Lemchak, M.

    2011-06-01

    Idaho National Laboratory is experimenting with electrical neutron generators, as potential replacements for californium-252 radioisotopic neutron sources in its PINS prompt gamma-ray neutron activation analysis (PGNAA) system for the identification of military chemical warfare agents and explosives. In addition to neutron output, we have recently measured the x-ray output of the Thermo Scientific P385 deuterium-deuterium neutron generator. X rays are a normal byproduct from neutron generators, but depending on their intensity and energy, x rays can interfere with gamma rays from the object under test, increase gamma-spectrometer dead time, and reduce PGNAA system throughput. The P385 x-ray energy spectrum was measured with a high-purity germanium (HPGe) detector, and a broad peak is evident at about 70 keV. To identify the source of the x rays within the neutron generator assembly, it was scanned by collimated scintillation detectors along its long axis. At the strongest x-ray emission points, the generator also was rotated 60° between measurements. The scans show the primary source of x-ray emission from the P385 neutron generator is an area 60 mm from the neutron production target, in the vicinity of the ion source. Rotation of the neutron generator did not significantly alter the x-ray count rate, and its x-ray emission appears to be axially symmetric. A thin lead shield, 3.2 mm (1/8 inch) thick, reduced the 70-keV generator x rays to negligible levels.

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ghag, Chamkaur

    Low background rare event searches in underground laboratories seeking observation of direct dark matter interactions or neutrino-less double beta decay have the potential to profoundly advance our understanding of the physical universe. Successful results from these experiments depend critically on construction from extremely radiologically clean materials and accurate knowledge of subsequent low levels of expected background. The experiments must conduct comprehensive screening campaigns to reduce radioactivity from detector components, and these measurements also inform detailed characterisation and quantification of background sources and their impact, necessary to assign statistical significance to any potential discovery. To provide requisite sensitivity for material screeningmore » and characterisation in the UK to support our rare event search activities, we have re-developed our infrastructure to add ultra-low background capability across a range of complementary techniques that collectively allow complete radioactivity measurements. Ultra-low background HPGe and BEGe detectors have been installed at the Boulby Underground Laboratory, itself undergoing substantial facility re-furbishment, to provide high sensitivity gamma spectroscopy in particular for measuring the uranium and thorium decay series products. Dedicated low-activity mass spectrometry instrumentation has been developed at UCL for part per trillion level contaminant identification to complement underground screening with direct U and Th measurements, and meet throughput demands. Finally, radon emanation screening at UCL measures radon background inaccessible to gamma or mass spectrometry techniques. With this new capability the UK is delivering half of the radioactivity screening for the LZ dark matter search experiment.« less

  3. The Application of High Energy Resolution Green's Functions to Threat Scenario Simulation

    NASA Astrophysics Data System (ADS)

    Thoreson, Gregory G.; Schneider, Erich A.

    2012-04-01

    Radiation detectors installed at key interdiction points provide defense against nuclear smuggling attempts by scanning vehicles and traffic for illicit nuclear material. These hypothetical threat scenarios may be modeled using radiation transport simulations. However, high-fidelity models are computationally intensive. Furthermore, the range of smuggler attributes and detector technologies create a large problem space not easily overcome by brute-force methods. Previous research has demonstrated that decomposing the scenario into independently simulated components using Green's functions can simulate photon detector signals with coarse energy resolution. This paper extends this methodology by presenting physics enhancements and numerical treatments which allow for an arbitrary level of energy resolution for photon transport. As a result, spectroscopic detector signals produced from full forward transport simulations can be replicated while requiring multiple orders of magnitude less computation time.

  4. DQE simulation of a-Se x-ray detectors using ARTEMIS

    NASA Astrophysics Data System (ADS)

    Fang, Yuan; Badano, Aldo

    2016-03-01

    Detective Quantum Efficiency (DQE) is one of the most important image quality metrics for evaluating the spatial resolution performance of flat-panel x-ray detectors. In this work, we simulate the DQE of amorphous selenium (a-Se) xray detectors with a detailed Monte Carlo transport code (ARTEMIS) for modeling semiconductor-based direct x-ray detectors. The transport of electron-hole pairs is achieved with a spatiotemporal model that accounts for recombination and trapping of carriers and Coulombic effects of space charge and external applied electric field. A range of x-ray energies has been simulated from 10 to 100 keV. The DQE results can be used to study the spatial resolution characteristics of detectors at different energies.

  5. Simulation of the GEM detector for BM@N experiment

    NASA Astrophysics Data System (ADS)

    Baranov, Dmitriy; Rogachevsky, Oleg

    2017-03-01

    The Gas Electron Multiplier (GEM) detector is one of the basic parts of the BM@N experiment included in the NICA project. The simulation model that takes into account features of signal generation process in an ionization GEM chamber is presented in this article. Proper parameters for the simulation were extracted from data retrieved with the help of Garfield++ (a toolkit for the detailed simulation of particle detectors). Due to this, we are able to generate clusters in layers of the micro-strip readout that correspond to clusters retrieved from a real physics experiment.

  6. Miles Hand Grenade

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Harrington, John J.; Buttz, James H.; Maish, Alex B.

    2005-11-15

    A simulated grenade for MILES-type simulations generates a unique RF signal and a unique audio signal. A detector utilizes the time between receipt of the RF signal and the slower-traveling audio signal to determine the distance between the detector and the simulated grenade.

  7. Depth profile of production yields of natPb(p, xn) 206,205,204,203,202,201Bi nuclear reactions

    NASA Astrophysics Data System (ADS)

    Mokhtari Oranj, Leila; Jung, Nam-Suk; Kim, Dong-Hyun; Lee, Arim; Bae, Oryun; Lee, Hee-Seock

    2016-11-01

    Experimental and simulation studies on the depth profiles of production yields of natPb(p, xn) 206,205,204,203,202,201Bi nuclear reactions were carried out. Irradiation experiments were performed at the high-intensity proton linac facility (KOMAC) in Korea. The targets, irradiated by 100-MeV protons, were arranged in a stack consisting of natural Pb, Al, Au foils and Pb plates. The proton beam intensity was determined by activation analysis method using 27Al(p, 3p1n)24Na, 197Au(p, p1n)196Au, and 197Au(p, p3n)194Au monitor reactions and also by Gafchromic film dosimetry method. The yields of produced radio-nuclei in the natPb activation foils and monitor foils were measured by HPGe spectroscopy system. Monte Carlo simulations were performed by FLUKA, PHITS/DCHAIN-SP, and MCNPX/FISPACT codes and the calculated data were compared with the experimental results. A satisfactory agreement was observed between the present experimental data and the simulations.

  8. ATLAS Simulation using Real Data: Embedding and Overlay

    NASA Astrophysics Data System (ADS)

    Haas, Andrew; ATLAS Collaboration

    2017-10-01

    For some physics processes studied with the ATLAS detector, a more accurate simulation in some respects can be achieved by including real data into simulated events, with substantial potential improvements in the CPU, disk space, and memory usage of the standard simulation configuration, at the cost of significant database and networking challenges. Real proton-proton background events can be overlaid (at the detector digitization output stage) on a simulated hard-scatter process, to account for pileup background (from nearby bunch crossings), cavern background, and detector noise. A similar method is used to account for the large underlying event from heavy ion collisions, rather than directly simulating the full collision. Embedding replaces the muons found in Z→μμ decays in data with simulated taus at the same 4-momenta, thus preserving the underlying event and pileup from the original data event. In all these cases, care must be taken to exactly match detector conditions (beamspot, magnetic fields, alignments, dead sensors, etc.) between the real data event and the simulation. We will discuss the status of these overlay and embedding techniques within ATLAS software and computing.

  9. New transitions and feeding of the Jπ=(8+) isomer in 186Re

    NASA Astrophysics Data System (ADS)

    Matters, D. A.; Fotiades, N.; Carroll, J. J.; Chiara, C. J.; McClory, J. W.; Kawano, T.; Nelson, R. O.; Devlin, M.

    2015-11-01

    The spallation neutron source at the Los Alamos Neutron Science Center Weapons Neutron Research facility was used to populate excited states in 186Re via (n ,2 n γ ) reactions on an enriched 187Re target. Gamma rays were detected with the GErmanium Array for Neutron Induced Excitations spectrometer, a Compton-suppressed array of 18 HPGe detectors. Incident neutron energies were determined by the time-of-flight technique and used to obtain γ -ray excitation functions for the purpose of identifying γ rays by reaction channel. Analysis of the singles γ -ray spectrum gated on the neutron energy range 10 ≤En≤25 MeV resulted in five transitions and one level added to the 186Re level scheme. The additions include the placement of three γ rays at 266.7, 381.2, and 647.7 keV which have been identified as feeding the 2.0 ×105yr , Jπ=(8+) isomer and yield an improved value of 148.2 (5 )keV for the isomer energy. These transitions may have astrophysical implications related to the use of the Re-Os cosmochronometer.

  10. New search for double electron capture in {sup 106}Cd decay with the TGV-2 spectrometer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Briançon, Ch.; Brudanin, V. B.; Egorov, V. G.

    2015-09-15

    A new experiment devoted to searches for double electron capture in {sup 106}Cd decay is being performed at the Modane underground laboratory (4800 mwe) with the 32-detector TGV-2 spectrometer. The limit T{sub 1/2}(2νEC/EC) > 2.0×10{sup 20} yr at a 90%confidence level (C.L.) was obtained from a preliminary analysis of data obtained over 2250 h of measurements with about 23.2 g sample enriched in the isotope {sup 106}Cd to 99.57%. The limits T{sub 1/2}(KL, 2741 keV) > 0.9 × 10{sup 20} yr and T{sub 1/2}(KK, 2718 keV) ≫ 1.4 × 10{sup 20} yr at a 90% C.L. on the neutrinoless decaymore » of {sup 106}Cd were obtained from measurements performed with the Obelix low-background spectrometer from high-purity germanium (HPGe spectrometer) for a sample of mass about 23.2 g enriched in the isotope {sup 106}Cd.« less

  11. Dead time corrections for inbeam γ-spectroscopy measurements

    NASA Astrophysics Data System (ADS)

    Boromiza, M.; Borcea, C.; Negret, A.; Olacel, A.; Suliman, G.

    2017-08-01

    Relatively high counting rates were registered in a proton inelastic scattering experiment on 16O and 28Si using HPGe detectors which was performed at the Tandem facility of IFIN-HH, Bucharest. In consequence, dead time corrections were needed in order to determine the absolute γ-production cross sections. Considering that the real counting rate follows a Poisson distribution, the dead time correction procedure is reformulated in statistical terms. The arriving time interval between the incoming events (Δt) obeys an exponential distribution with a single parameter - the average of the associated Poisson distribution. We use this mathematical connection to calculate and implement the dead time corrections for the counting rates of the mentioned experiment. Also, exploiting an idea introduced by Pommé et al., we describe a consistent method for calculating the dead time correction which completely eludes the complicated problem of measuring the dead time of a given detection system. Several comparisons are made between the corrections implemented through this method and by using standard (phenomenological) dead time models and we show how these results were used for correcting our experimental cross sections.

  12. Systematic study of proton capture reactions in medium-mass nuclei relevant to the p process: The case of 103Rh and In,115113

    NASA Astrophysics Data System (ADS)

    Harissopulos, S.; Spyrou, A.; Foteinou, V.; Axiotis, M.; Provatas, G.; Demetriou, P.

    2016-02-01

    The cross sections of the 103Rh(p ,γ )104Pd and the In,115113(p ,γ )Sn,116114 reactions have been determined from γ angular distribution measurements carried out at beam energies from 2 to 3.5 MeV. An array of four highly efficient HPGe detectors all shielded with BGO crystals for Compton background suppression was used. Astrophysical S factors and reaction rates were deduced from the measured cross sections. Statistical model calculations were performed using the Hauser-Feshbach (HF) code TALYS and were compared with the new data. A good agreement between theory and experiment was found. In addition, the effect of different combinations of the nuclear input parameters entering the HF calculations on the ground-state reaction rates was investigated. It was found that these rates differ by a factor 3 at the most, being thus within the average discrepancies observed between calculated p -nuclei abundances and observations, if certain combinations of optical model potentials, nuclear level densities, and γ -ray strength functions are used.

  13. Non destructive multi elemental analysis using prompt gamma neutron activation analysis techniques: Preliminary results for concrete sample

    NASA Astrophysics Data System (ADS)

    Dahing, Lahasen@Normanshah; Yahya, Redzuan; Yahya, Roslan; Hassan, Hearie

    2014-09-01

    In this study, principle of prompt gamma neutron activation analysis has been used as a technique to determine the elements in the sample. The system consists of collimated isotopic neutron source, Cf-252 with HPGe detector and Multichannel Analysis (MCA). Concrete with size of 10×10×10 cm3 and 15×15×15 cm3 were analysed as sample. When neutrons enter and interact with elements in the concrete, the neutron capture reaction will occur and produce characteristic prompt gamma ray of the elements. The preliminary result of this study demonstrate the major element in the concrete was determined such as Si, Mg, Ca, Al, Fe and H as well as others element, such as Cl by analysis the gamma ray lines respectively. The results obtained were compared with NAA and XRF techniques as a part of reference and validation. The potential and the capability of neutron induced prompt gamma as tool for multi elemental analysis qualitatively to identify the elements present in the concrete sample discussed.

  14. Study of dietary supplements compositions by neutron activation analysis at the VR-1 training reactor

    NASA Astrophysics Data System (ADS)

    Stefanik, Milan; Rataj, Jan; Huml, Ondrej; Sklenka, Lubomir

    2017-11-01

    The VR-1 training reactor operated by the Czech Technical University in Prague is utilized mainly for education of students and training of various reactor staff; however, R&D is also carried out at the reactor. The experimental instrumentation of the reactor can be used for the irradiation experiments and neutron activation analysis. In this paper, the neutron activation analysis (NAA) is used for a study of dietary supplements containing the zinc (one of the essential trace elements for the human body). This analysis includes the dietary supplement pills of different brands; each brand is represented by several different batches of pills. All pills were irradiated together with the standard activation etalons in the vertical channel of the VR-1 reactor at the nominal power (80 W). Activated samples were investigated by the nuclear gamma-ray spectrometry technique employing the semiconductor HPGe detector. From resulting saturated activities, the amount of mineral element (Zn) in the pills was determined using the comparative NAA method. The results show clearly that the VR-1 training reactor is utilizable for neutron activation analysis experiments.

  15. Studies on mass attenuation coefficient, effective atomic number and electron density of some thermoluminescent dosimetric compounds

    NASA Astrophysics Data System (ADS)

    Önder, P.; Turşucu, A.; Demir, D.; Gürol, A.

    2012-12-01

    Mass attenuation coefficient, μm , effective atomic number, Zeff, and effective electron density, Nel, were determined experimentally and theoretically for some thermoluminescent dosimetric (TLD) compounds such as MgSO4, CdSO4, Al2O3, Mg2SiO4, ZnSO4, CaSO4, CaF2, NaSO4, Na4P2O7, Ca5F(PO4)3, SiO2, CaCO3 and BaSO4 at 8.04, 8.91, 13.37, 14.97, 17.44, 19.63, 22.10, 24.90, 30.82, 32.06, 35.40, 36.39, 37.26, 43.74, 44.48, 50.38, 51.70, 53.16, 80.99, 276.40, 302.85, 356.01, 383.85 and 661.66 keV photon energies by using an HPGe detector with a resolution of 182 eV at 5.9 keV. The theoretical mass attenuation coefficients were estimated using mixture rule. The calculated values were compared with the experimental values for all compounds. Good agreement has been observed between experimental and theoretical values within experimental uncertainties.

  16. Measurements Conducted on an Unknown Object Labeled Pu-239

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hoteling, Nathan

    Measurements were carried out on 12 November 2013 to determine whether Pu-239 was present on an object discovered in a plastic bag with label “Pu-­239 6 uCi.” Following initial survey measurements to verify that the object was not leaking or contaminated, spectra were collected with a High Purity Germanium (HPGe) detector with object positioned in two different configurations. Analysis of the spectra did not yield any direct evidence of Pu-­239. From the measured spectra, minimum detectable activity (MDA) was determined to be approximately 2 uCi for the gamma-­ray measurements. Although there was no direct evidence of Pu-239, a peak atmore » 60 keV characteristic of Am-­241 decay was observed. Since it is very likely that Am-­241 would be present in aged plutonium samples, this was interpreted as indirect evidence for the presence of plutonium on the object. Analysis of this peak led to an estimated Pu-­239 activity of 0.02–0.04 uCi, or <1x10 -6 grams.« less

  17. Reaction rates of the 113In(γ,n)112mIn and 115In(γ,n)114mIn

    NASA Astrophysics Data System (ADS)

    Skakun, Ye; Semisalov, I.; Kasilov, V.; Popov, V.; Kochetov, S.; Maslyuk, V.; Mazur, V.; Parlag, O.; Gajnish, I.

    2016-01-01

    The integral yields of the 113In(γ,n)112mIn (Jπ=9/2+→Jπ=4+) and 115In(γ,n)114mIn (Jπ=9/2+→Jπ=5+) photonuclear reactions were measured in the bremsstrahlung end-point energy range from the respective thresholds up to 14 MeV by a conventional activation/decay technique using the 197Au(γ,n)196Au reaction cross sections as the standard for the absolute photon intensity determination. The metallic indium samples of the natural and enriched compositions were irradiated by the bremsstrahlung beams from thin tantalum converters of the electron linear accelerator of NSC KIPT (Kharkiv) and the microtron of IEP (Ughhorod). The integral reaction yields were determined from the activities of the nuclei-products measured by the high resolution γ-ray spectrometry technique with Ge(Li)- and HPGe-detectors. The reaction rates for the Planck spectrum of a thermal photon bath were derived for the ground state target nuclei and compared to the predictions of the statistical model of nuclear reactions.

  18. Measurement of the strengths of the resonances at 417, 458, 611, 632 and 1222 keV in the 22Ne(p, γ)23Na reaction

    NASA Astrophysics Data System (ADS)

    Ferraro, Federico

    2018-01-01

    The 22Ne(p, γ)23Na reaction is part of the NeNa cycle of hydrogen burning. This cycle plays a key role in the nucleosynthesis of the elements between 20Ne and 27Al in red giant stars, asymptotic giant stars and classical nova explosions. The strengths of the resonances at proton energies above 400 keV are still affected by high uncertainty. In order to reduce this uncertainty, a precision study of some of the most intense resonances between 400 keV and 1250 keV has been performed at the HZDR 3 MV Tandetron. The target, made of 22Ne implanted in a 0.22 mm thick Ta backing, has been characterized using the 1222 keV and 458 keV resonances, well known in literature. Subsequently, the strengths of the resonances at 417, 458, 611, 632 and 1222 keV were determined. Two HPGe detectors equipped with active anti-Compton shielding have been used.

  19. Assay Methods for 238U, 232Th, and 210Pb in Lead and Calibration of 210Bi Bremsstrahlung Emission from Lead

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Orrell, John L.; Aalseth, Craig E.; Arnquist, Isaac J.

    2016-02-13

    Assay methods for measuring 238U, 232Th, and 210Pb concentrations in refined lead are presented. The 238U and 232Th concentrations are assayed via inductively coupled plasma mass spectrometry (ICP-MS) after anion exchange column separation on dissolved lead samples. The 210Pb concentration is inferred through α-spectroscopy of a daughter isotope, 210Po, after chemical precipitation separation on dissolved lead samples. Subsequent to the 210Po α-spectroscopy assay, a method for evaluating 210Pb concentrations in solid lead samples was developed via measurement of bremsstrahlung radiation from β-decay of a daughter isotope, 210Bi, by employing a 14-crystal array of high purity germanium (HPGe) detectors. Ten sourcesmore » of refined lead were assayed. The 238U concentrations were <34 microBq/kg and the 232Th concentrations ranged <0.6 – 15 microBq/kg, as determined by the ICP-MS assay method. The 210Pb concentrations ranged from ~0.1 – 75 Bq/kg, as inferred by the 210Po α-spectroscopy assay method.« less

  20. Cosmic veto gamma-spectrometry for Comprehensive Nuclear-Test-Ban Treaty samples

    NASA Astrophysics Data System (ADS)

    Burnett, J. L.; Davies, A. V.

    2014-05-01

    The Comprehensive Nuclear-Test-Ban Treaty (CTBT) is supported by a global network of monitoring stations that perform high-resolution gamma-spectrometry on air filter samples for the identification of 85 radionuclides. At the UK CTBT Radionuclide Laboratory (GBL15), a novel cosmic veto gamma-spectrometer has been developed to improve the sensitivity of station measurements, providing a mean background reduction of 80.8% with mean MDA improvements of 45.6%. The CTBT laboratory requirement for a 140Ba MDA is achievable after 1.5 days counting compared to 5-7 days using conventional systems. The system consists of plastic scintillation plates that detect coincident cosmic-ray interactions within an HPGe gamma-spectrometer using the Canberra LynxTM multi-channel analyser. The detector is remotely configurable using a TCP/IP interface and requires no dedicated coincidence electronics. It would be especially useful in preventing false-positives at remote station locations (e.g. Halley, Antarctica) where sample transfer to certified laboratories is logistically difficult. The improved sensitivity has been demonstrated for a CTBT air filter sample collected after the Fukushima incident.

  1. Radiological impact of natural radioactivity in Egyptian phosphate rocks, phosphogypsum and phosphate fertilizers.

    PubMed

    El-Bahi, S M; Sroor, A; Mohamed, Gehan Y; El-Gendy, N S

    2017-05-01

    In this study, the activity concentrations of the natural radionuclides in phosphate rocks and its products were measured using a high- purity germanium detector (HPGe). The obtained activity results show remarkable wide variation in the radioactive contents for the different phosphate samples. The average activity concentration of 235 U, 238 U, 226 Ra, 232 Th and 40 K was found as (45, 1031, 786, 85 and 765Bq/kg) for phosphate rocks, (28, 1234, 457, 123 and 819Bq/kg) for phosphate fertilizers, (47, 663, 550, 79 and 870Bq/kg) for phosphogypsum and (25, 543, 409, 54 and 897Bq/kg) for single super phosphate respectively. Based on the measured activities, the radiological parameters (activity concentration index, absorbed gamma dose rate in outdoor and indoor and the corresponding annual effective dose rates and total excess lifetime cancer risk) were estimated to assess the radiological hazards. The total excess lifetime cancer risk (ELCR) has been calculated and found to be high in all samples, which related to high radioactivity, representing radiological risk for the health of the population. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. 197Au(n ,2 n ) reaction cross section in the 15-21 MeV energy range

    NASA Astrophysics Data System (ADS)

    Kalamara, A.; Vlastou, R.; Kokkoris, M.; Nicolis, N. G.; Patronis, N.; Serris, M.; Michalopoulou, V.; Stamatopoulos, A.; Lagoyannis, A.; Harissopulos, S.

    2018-03-01

    The cross section of the 197Au(n ,2 n )196Au reaction has been determined at six energies ranging from 15.3-20.9 MeV by means of the activation technique, relative to the 27Al(n ,α )24Na reaction. Quasimonoenergetic neutron beams were produced via the 3H(d ,n )4He reaction at the 5.5 MV Tandem T11/25 accelerator laboratory of NCSR "Demokritos". After the irradiations, the induced γ -ray activity of the target and reference foils was measured with high-resolution HPGe detectors. The cross section for the high spin isomeric state (12-) was determined along with the sum of the ground (2-), the first (5+), and second (12-) isomeric states. Theoretical calculations were carried out with the codes empire 3.2.2 and talys 1.8. Optimum input parameters were chosen in such a way as to simultaneously reproduce several experimental reaction channel cross sections in a satisfactory way, namely the (n ,elastic ), (n ,2 n ), (n ,3 n ), (n ,p ), (n ,α ), and (n ,total) ones.

  3. Committed effective dose determination in southern Brazilian cereal flours.

    PubMed

    Scheibel, V; Appoloni, C R

    2013-01-01

    The health impact of radionuclide ingestion from foodstuffs was evaluated by the committed effective doses determined in eight commercial samples of South-Brazilian cereal flours (soy, wheat, cornmeal, cassava, rye, oat, barley and rice flours). The radioactivity traces of (228)Th, (228)Ra, (226)Ra, (40)K, (7)Be and (137)Cs were measured by gamma-ray spectrometry employing an HPGe detector of 66 % relative efficiency. The efficiency curve has taken into account the differences in densities and chemical composition between the matrix and the certified sample. The highest concentration levels of (228)Th and (40)K were 3.5±0.4 and 1469±17 Bq kg(-1) for soy flour, respectively, within the 95 % confidence level. The lower limit of detection for (137)Cs ranged from 0.04 to 0.4 Bq kg(-1). The highest committed effective dose was 0.36 μSv.y(-1) for (228)Ra in cassava flour (adults). All committed effective doses determined at the present work were lower than the International Atomic Energy Agency dose limit of 1 mSv.y(-1), to the public exposure.

  4. The proton radius puzzle

    NASA Astrophysics Data System (ADS)

    Bonesini, Maurizio

    2017-12-01

    The FAMU (Fisica degli Atomi Muonici) experiment has the goal to measure precisely the proton Zemach radius, thus contributing to the solution of the so-called proton radius "puzzle". To this aim, it makes use of a high-intensity pulsed muon beam at RIKEN-RAL impinging on a cryogenic hydrogen target with an high-Z gas admixture and a tunable mid-IR high power laser, to measure the hyperfine (HFS) splitting of the 1S state of the muonic hydrogen. From the value of the exciting laser frequency, the energy of the HFS transition may be derived with high precision ( 10-5) and thus, via QED calculations, the Zemach radius of the proton. The experimental apparatus includes a precise fiber-SiPMT beam hodoscope and a crown of eight LaBr3 crystals and a few HPGe detectors for detection of the emitted characteristic X-rays. Preliminary runs to optimize the gas target filling and its operating conditions have been taken in 2014 and 2015-2016. The final run, with the pump laser to drive the HFS transition, is expected in 2018.

  5. Analysis of SMELS and reference materials for validation of the k0-based internal monostandard NAA method using in-situ detection efficiency

    NASA Astrophysics Data System (ADS)

    Acharya, R.; Swain, K. K.; Reddy, A. V. R.

    2010-10-01

    Three synthetic multielement standards (SMELS I, II and III) and two reference materials (RMs), SL-3 and Soil-7 of IAEA were analyzed for validation of the k0-based internal monostandard neutron activation analysis (IM-NAA) method utilizing in-situ relative detection efficiency. The internal monostandards used in SMELS and RMs were Au and Sc, respectively. The samples were irradiated in Apsara and Dhruva reactors, BARC and radioactive assay was carried out using a 40% relative efficiency HPGe detector coupled to an 8 k MCA. Concentrations of 23 elements were determined in both SMELS and RMs. In the case of RMs, concentrations of a few elements, whose certified values are not available, could also be determined. The % deviations for the elements determined in SMELS with respect to the assigned values and RMs with respect to certified values were within ±8%. The Z-score values at 95% confidence level for most of the elements in both the materials were within ±1.

  6. Half-life Measurements of Excited Levels in Fission Products around Mass Number 150

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kojima, Y., E-mail: kojima.yasuaki@f.mbox.nagoya-u.ac.jp; Shima, Y.; Hayashi, H.

    2014-06-15

    A spectrometer to measure nuclear level half-lives has been installed at the on-line isotope separator of the Kyoto University Reactor. This spectrometer consists of a LaBr3 scintillator, a thin plastic scintillator and an HPGe detector. Half-lives are deduced using the β-γ-γ delayed coincidence method. The prompt-time distribution curves measured with the spectrometer give a time resolution (FWHM) of 600 ps for 100-keV γ rays. This resolution means that half-lives down to the subnanosecond range or shorter can be measured. We reported recent measurements of the half-life of {sup 149}Pr and {sup 149}Nd. Some of the more interesting results include themore » first determination of the half-lives of {sup 149}Pr levels at 86.5 and 125.6 keV, which are 4.2(5) ns and 1.0(2) ns, respectively. In addition, the data indicate that the half-life of the 270.8-keV level in {sup 149}Nd is not 5.1(3) ns as reported previously, but 0.42(3) ns.« less

  7. [Experimental study and correction of the absorption and enhancement effect between Ti, V and Fe].

    PubMed

    Tuo, Xian-Guo; Mu, Ke-Liang; Li, Zhe; Wang, Hong-Hui; Luo, Hui; Yang, Jian-Bo

    2009-11-01

    The absorption and enhancement effects in X-ray fluorescence analysis for Ti, V and Fe elements were studied in the present paper. Three bogus duality systems of Ti-V/Ti-Fe/V-Fe samples were confected and measured by X-ray fluorescence analysis technique using HPGe semiconductor detector, and the relation curve between unitary coefficient (R(K)) of element count rate and element content (W(K)) were obtained after the experiment. Having analyzed the degree of absorption and enhancement effect between every two elements, the authors get the result, and that is the absorption and enhancement effect between Ti and V is relatively distinctness, while it's not so distinctness in Ti-Fe and V-Fe. After that, a mathematics correction method of exponential fitting was used to fit the R(K)-W(K) curve and get a function equation of X-ray fluorescence count rate and content. Three groups of Ti-V duality samples were used to test the fitting method and the relative errors of Ti and V were less than 0.2% as compared to the actual results.

  8. Constraining the astrophysical 23Mg(p, γ)24Al reaction rate using the 23Na(d,p)24Na reaction

    NASA Astrophysics Data System (ADS)

    Bennett, E. A.; Catford, W. N.; Christian, G.; Dede, S.; Hallam, S.; Lotay, G.; Ota, S.; Saastamoinen, A.; Wilkinson, R.

    2017-09-01

    The 23Mg(p, γ)24Al reaction provides an escape from the Ne-Na cycle in classical novae and is therefore important in understanding nova nucleosynthesis in the A > 20 mass range. Although several resonances may contribute to the overall rate at novae temperatures, the resonance at 475 keV is thought to be dominant. The strength of this resonance has been directly measured using a radioactive 23Mg beam impinging on a windowless H2 gas target; however, recent high-precision 24Al mass measurements have called this result into question. Here we make an indirect measurement using the 23Na(d,p)24Na reaction in inverse kinematics to study the mirror state of the 475 keV resonance in 24Na. The experiment, performed at the Texas A&M Cyclotron Institute, utilized the TIARA silicon array, four HPGe detectors, and the MDM spectrometer to measure the excited states of the 24Na nucleus. Preliminary results from the experiment will be presented along with progress from the ongoing analysis.

  9. Implementation of the TDCR liquid scintillation method at CNEA-LMR, Argentina.

    PubMed

    Arenillas, Pablo; Cassette, Philippe

    2006-01-01

    During the last two years, a triple-to-double coincidence ratio (TDCR) system was assembled and adjusted at the CNEA-LMR, Argentina. The new counting system will add complementary capabilities to the absolute measurements section of the CNEA-LMR. This work describes its implementation and validation. Several checks and a set of beta-emitting standard solutions were used in order to perform the validation experiments. In preliminary measurements, a 3H LNHB solution with reference activity concentration of (119.7+/-0.9) kBq/g on 11 November 2003 was used. The CNEA-LMR TDCR counter gave, at the same reference date, an activity concentration of (120+/-1) kBq/g. Results and improvements are presented in detail. Concerning the asymmetry of the system, the quantum efficiency of the three photomultiplier tubes was studied for different operating conditions of the focusing voltage. The counter also includes an automatic system to change the efficiency by defocusing the photomultipliers and on the other hand, it was coupled to a HPGe detector to also measure beta-gamma coincidences.

  10. Customized compact neutron activation analysis system to quantify manganese (Mn) in bone in vivo

    PubMed Central

    Liu, Yingzi; Mostafaei, Farshad; Sowers, Daniel; Hsieh, Mindy; Zheng, Wei; Nie, Linda H

    2018-01-01

    Objective In the US alone, millions of workers, including over 300 000 welders, are at high risk of occupational manganese (Mn) exposure. Those who have been chronically exposed to excessive amount of Mn can develop severe neurological disorders similar, but not identical, to the idiopathic Parkinson’s disease. One challenge of identifing the health effects of Mn exposure is to find a reliable biomarker for exposure assessment, especially for long-term cumulative exposure. Approach Mn’s long biological half-life as well as its relatively high concentration in bone makes bone Mn (BnMn) a potentially valuable biomarker for Mn exposure. Our group has been working on the development of a deuterium–deuterium (D–D)-based neutron generator to quantify Mn in bone in vivo. Main results and significance In this paper, we report the latest advancements in our system. With a customized hand irradiation assembly, a fully characterized high purity germanium (HPGe) detector system, and an acceptable hand dose of 36 mSv, a detection limit of 0.64 µg Mn/g bone (ppm) has been achieved. PMID:28060775

  11. Design and implementation of a low-cost multiple-range digital phase detector

    NASA Astrophysics Data System (ADS)

    Omran, Hesham; Albasha, Lutfi; Al-Ali, A. R.

    2012-06-01

    This article describes the design, simulation, implementation and testing of a novel low-cost multiple-range programmable digital phase detector. The detector receives two periodic signals and calculates the ratio of the time difference to the time period to measure and display the phase difference. The resulting output values are in integer form ranging from -180° to 180°. Users can select the detector pre-set operation frequency ranges using a three-bit pre-scalar. This enables to use the detector for various applications. The proposed detector can be programmed over a frequency range of 10 Hz to 25 kHz by configuring its clock divider circuit. Detector simulations were conducted and verified using ModelSim and the design was implemented and tested using an Altera Cyclone II field-programmable gate array board. Both the simulation and actual circuit testing results showed that the phase detector has a magnitude of error of only 1°. The detector is ideal for applications such as power factor measurement and correction, self-tuning resonant circuits and in metal detection systems. Unlike other stand-alone phase detection systems, the reported system has the ability to be programmed to several frequency ranges, hence expanding its bandwidth.

  12. Fast Photon Monte Carlo for Water Cherenkov Detectors

    NASA Astrophysics Data System (ADS)

    Latorre, Anthony; Seibert, Stanley

    2012-03-01

    We present Chroma, a high performance optical photon simulation for large particle physics detectors, such as the water Cerenkov far detector option for LBNE. This software takes advantage of the CUDA parallel computing platform to propagate photons using modern graphics processing units. In a computer model of a 200 kiloton water Cerenkov detector with 29,000 photomultiplier tubes, Chroma can propagate 2.5 million photons per second, around 200 times faster than the same simulation with Geant4. Chroma uses a surface based approach to modeling geometry which offers many benefits over a solid based modelling approach which is used in other simulations like Geant4.

  13. Status of the Simbol-X Background Simulation Activities

    NASA Astrophysics Data System (ADS)

    Tenzer, C.; Briel, U.; Bulgarelli, A.; Chipaux, R.; Claret, A.; Cusumano, G.; Dell'Orto, E.; Fioretti, V.; Foschini, L.; Hauf, S.; Kendziorra, E.; Kuster, M.; Laurent, P.; Tiengo, A.

    2009-05-01

    The Simbol-X background simulation group is working towards a simulation based background and mass model which can be used before and during the mission. Using the Geant4 toolkit, a Monte-Carlo code to simulate the detector background of the Simbol-X focal plane instrument has been developed with the aim to optimize the design of the instrument. Achieving an overall low instrument background has direct impact on the sensitivity of Simbol-X and thus will be crucial for the success of the mission. We present results of recent simulation studies concerning the shielding of the detectors with respect to the diffuse cosmic hard X-ray background and to the cosmic-ray proton induced background. Besides estimates of the level and spectral shape of the remaining background expected in the low and high energy detector, also anti-coincidence rates and resulting detector dead time predictions are discussed.

  14. Simulation of the Interactions Between Gamma-Rays and Detectors Using BSIMUL

    NASA Technical Reports Server (NTRS)

    Haywood, S. E.; Rester, A. C., Jr.

    1996-01-01

    Progress made during 1995 on the Monte-Carlo gamma-ray spectrum simulation program BSIMUL is discussed. Several features have been added, including the ability to model shield that are tapered cylinders. Several simulations were made on the Near Earth Asteroid Rendezvous detector.

  15. Comparison of Fluka-2006 Monte Carlo Simulation and Flight Data for the ATIC Detector

    NASA Technical Reports Server (NTRS)

    Gunasingha, R.M.; Fazely, A.R.; Adams, J.H.; Ahn, H.S.; Bashindzhagyan, G.L.; Chang, J.; Christl, M.; Ganel, O.; Guzik, T.G.; Isbert, J.; hide

    2007-01-01

    We have performed a detailed Monte Carlo (MC) simulation for the Advanced Thin Ionization Calorimeter (ATIC) detector using the MC code FLUKA-2006 which is capable of simulating particles up to 10 PeV. The ATIC detector has completed two successful balloon flights from McMurdo, Antarctica lasting a total of more than 35 days. ATIC is designed as a multiple, long duration balloon flight, investigation of the cosmic ray spectra from below 50 GeV to near 100 TeV total energy; using a fully active Bismuth Germanate(BGO) calorimeter. It is equipped with a large mosaic of.silicon detector pixels capable of charge identification, and, for particle tracking, three projective layers of x-y scintillator hodoscopes, located above, in the middle and below a 0.75 nuclear interaction length graphite target. Our simulations are part of an analysis package of both nuclear (A) and energy dependences for different nuclei interacting in the ATIC detector. The MC simulates the response of different components of the detector such as the Si-matrix, the scintillator hodoscopes and the BGO calorimeter to various nuclei. We present comparisons of the FLUKA-2006 MC calculations with GEANT calculations and with the ATIC CERN data and ATIC flight data.

  16. Temperature distribution model for the semiconductor dew point detector

    NASA Astrophysics Data System (ADS)

    Weremczuk, Jerzy; Gniazdowski, Z.; Jachowicz, Ryszard; Lysko, Jan M.

    2001-08-01

    The simulation results of temperature distribution in the new type silicon dew point detector are presented in this paper. Calculations were done with use of the SMACEF simulation program. Fabricated structures, apart from the impedance detector used to the dew point detection, contained the resistive four terminal thermometer and two heaters. Two detector structures, the first one located on the silicon membrane and the second one placed on the bulk materials were compared in this paper.

  17. GEANT4 simulations of a novel 3He-free thermalization neutron detector

    NASA Astrophysics Data System (ADS)

    Mazzone, A.; Finocchiaro, P.; Lo Meo, S.; Colonna, N.

    2018-05-01

    A novel concept for 3He-free thermalization detector is here investigated by means of GEANT4 simulations. The detector is based on strips of solid-state detectors with 6Li deposit for neutron conversion. Various geometrical configurations have been investigated in order to find the optimal solution, in terms of value and energy dependence of the efficiency for neutron energies up to 10 MeV. The expected performance of the new detector are compared with those of an optimized thermalization detector based on standard 3He tubes. Although an 3He-based detector is superior in terms of performance and simplicity, the proposed solution may become more appealing in terms of costs in case of shortage of 3He supply.

  18. Accuracy of Monte Carlo photon transport simulation in characterizing brachytherapy dosimeter energy-response artefacts.

    PubMed

    Das, R K; Li, Z; Perera, H; Williamson, J F

    1996-06-01

    Practical dosimeters in brachytherapy, such as thermoluminescent dosimeters (TLD) and diodes, are usually calibrated against low-energy megavoltage beams. To measure absolute dose rate near a brachytherapy source, it is necessary to establish the energy response of the detector relative to that of the calibration energy. The purpose of this paper is to assess the accuracy of Monte Carlo photon transport (MCPT) simulation in modelling the absolute detector response as a function of detector geometry and photon energy. We have exposed two different sizes of TLD-100 (LiF chips) and p-type silicon diode detectors to calibrated 60Co, HDR source (192Ir) and superficial x-ray beams. For the Scanditronix electron-field diode, the relative detector response, defined as the measured detector readings per measured unit of air kerma, varied from 38.46 V cGy-1 (40 kVp beam) to 6.22 V cGy-1 (60Co beam). Similarly for the large and small chips the same quantity varied from 2.08-3.02 nC cGy-1 and 0.171-0.244 nC cGy-1, respectively. Monte Carlo simulation was used to calculate the absorbed dose to the active volume of the detector per unit air kerma. If the Monte Carlo simulation is accurate, then the absolute detector response, which is defined as the measured detector reading per unit dose absorbed by the active detector volume, and is calculated by Monte Carlo simulation, should be a constant. For the diode, the absolute response is 5.86 +/- 0.15 (V cGy-1). For TLDs of size 3 x 3 x 1 mm3 the absolute response is 2.47 +/- 0.07 (nC cGy-1) and for TLDs of 1 x 1 x 1 mm3 it is 0.201 +/- 0.008 (nC cGy-1). From the above results we can conclude that the absolute response function of detectors (TLDs and diodes) is directly proportional to absorbed dose by the active volume of the detector and is independent of beam quality.

  19. LArSoft: toolkit for simulation, reconstruction and analysis of liquid argon TPC neutrino detectors

    NASA Astrophysics Data System (ADS)

    Snider, E. L.; Petrillo, G.

    2017-10-01

    LArSoft is a set of detector-independent software tools for the simulation, reconstruction and analysis of data from liquid argon (LAr) neutrino experiments The common features of LAr time projection chambers (TPCs) enable sharing of algorithm code across detectors of very different size and configuration. LArSoft is currently used in production simulation and reconstruction by the ArgoNeuT, DUNE, LArlAT, MicroBooNE, and SBND experiments. The software suite offers a wide selection of algorithms and utilities, including those for associated photo-detectors and the handling of auxiliary detectors outside the TPCs. Available algorithms cover the full range of simulation and reconstruction, from raw waveforms to high-level reconstructed objects, event topologies and classification. The common code within LArSoft is contributed by adopting experiments, which also provide detector-specific geometry descriptions, and code for the treatment of electronic signals. LArSoft is also a collaboration of experiments, Fermilab and associated software projects which cooperate in setting requirements, priorities, and schedules. In this talk, we outline the general architecture of the software and the interaction with external libraries and detector-specific code. We also describe the dynamics of LArSoft software development between the contributing experiments, the projects supporting the software infrastructure LArSoft relies on, and the core LArSoft support project.

  20. Technical Note: Detective quantum efficiency simulation of a-Se imaging detectors using ARTEMIS.

    PubMed

    Fang, Yuan; Ito, Takaaki; Nariyuki, Fumito; Kuwabara, Takao; Badano, Aldo; Karim, Karim S

    2017-08-01

    This work studies the detective quantum efficiency (DQE) of a-Se-based solid state x-ray detectors for medical imaging applications using ARTEMIS, a Monte Carlo simulation tool for modeling x-ray photon, electron and charged carrier transport in semiconductors with the presence of applied electric field. ARTEMIS is used to model the signal formation process in a-Se. The simulation model includes x-ray photon and high-energy electron interactions, and detailed electron-hole pair transport with applied detector bias taking into account drift, diffusion, Coulomb interactions, recombination and trapping. For experimental validation, the DQE performance of prototype a-Se detectors is measured following IEC Testing Standard 62220-1-3. Comparison of simulated and experimental DQE results show reasonable agreement for RQA beam qualities. Experimental validation demonstrated within 5% percentage difference between simulation and experimental DQE results for spatial frequency above 0.25 cycles/mm using uniform applied electric field for RQA beam qualities (RQA5, RQA7 and RQA9). Results include two different prototype detectors with thicknesses of 240 μm and 1 mm. ARTEMIS can be used to model the DQE of a-Se detectors as a function of x-ray energy, detector thickness, and spatial frequency. The ARTEMIS model can be used to improve understanding of the physics of x-ray interactions in a-Se and in optimization studies for the development of novel medical imaging applications. © 2017 American Association of Physicists in Medicine.

  1. Gamma-Ray Holdup Measurements of U-235, Np-237, and Am-241 Content in the C and D Out-gassing Ovens in the Deactivation and Decommissioning Activities in 321-M

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    RAYMOND, DEWBERRY

    2004-09-16

    The Analytical Development Section of Savannah River National Laboratory (SRNL) was requested by the Facilities Disposition Projects (FDP) to determine the holdup of enriched uranium in the 321-M facility as part of an overall deactivation project of the facility. The 321-M facility was used to fabricate enriched uranium fuel assemblies, lithium-aluminum target tubes, neptunium assemblies, and miscellaneous components for the production reactors. The results of the holdup assays are essential for determining compliance with the Waste Acceptance Criteria, Material Control and Accountability, and to meet criticality safety controls. This report covers holdup measurements in the C and D out-gassing ovensmore » that were used to remove gas entrained in billet assembly material prior to the billets being extruded into rods by the extrusion press. A portable high purity germanium (HPGe) detection system and a portable sodium iodide (NaI) detection system were used to determine highly enriched uranium (HEU) holdup and to determine holdup of Np-237 and Am-241 that were observed in these components. The HPGe detector was run by an EG and G Dart (TM) system that contains the high voltage power supply and signal processing electronics. A personal computer with Gamma-Vision software was used to control the Dart (TM) MCA and provide space to store and manipulate multiple 4096-channel spectra. The NaI detector was run with a Canberra NaI plus MCA card that converts a personal computer to a full function multichannel analyzer and with Canberra Genie-2000 acquisition and analysis software. The measured Np-237 and Am-241 contents were especially important in these components because their presence is unusual and unexpected in 321-M. It was important to obtain a measured value of these two species to disposition the out-gassing ovens and to determine whether a separate waste stream was necessary for release of these contaminated components to the E-Area Solid Waste Vault. The reported values for Np-237 are (17 plus or minus 7) mg in oven C and less than 0.5 mg in oven D. The reported values for Am-241 are (1.3 plus or minus 0.2) in oven C and less than 400 ng in oven D. Our results indicate an upper limit of U-235 content of 0.2 g for oven C and (0.105 plus or minus 0.048) g in oven D. This report discusses the methodology, non-destructive assay (NDA) measurements, and results of the holdup measured for each of the three actinide species in these out-gassing ovens.« less

  2. Determination of output factor for 6 MV small photon beam: comparison between Monte Carlo simulation technique and microDiamond detector

    NASA Astrophysics Data System (ADS)

    Krongkietlearts, K.; Tangboonduangjit, P.; Paisangittisakul, N.

    2016-03-01

    In order to improve the life's quality for a cancer patient, the radiation techniques are constantly evolving. Especially, the two modern techniques which are intensity modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) are quite promising. They comprise of many small beam sizes (beamlets) with various intensities to achieve the intended radiation dose to the tumor and minimal dose to the nearby normal tissue. The study investigates whether the microDiamond detector (PTW manufacturer), a synthetic single crystal diamond detector, is suitable for small field output factor measurement. The results were compared with those measured by the stereotactic field detector (SFD) and the Monte Carlo simulation (EGSnrc/BEAMnrc/DOSXYZ). The calibration of Monte Carlo simulation was done using the percentage depth dose and dose profile measured by the photon field detector (PFD) of the 10×10 cm2 field size with 100 cm SSD. Comparison of the values obtained from the calculations and measurements are consistent, no more than 1% difference. The output factors obtained from the microDiamond detector have been compared with those of SFD and Monte Carlo simulation, the results demonstrate the percentage difference of less than 2%.

  3. Quantitative comparison of simulated and measured signals in the STEM mode of a SEM

    NASA Astrophysics Data System (ADS)

    Walker, C. G. H.; Konvalina, I.; Mika, F.; Frank, L.; Müllerová, I.

    2018-01-01

    The transmission of electrons with energies 15 keV and 30 keV through Si and Au films of 100 nm thickness each have been studied in a Scanning Transmission Electron Microscope. The electrons that were transmitted through the films were detected using a multi-annular photo-detector consisting of a central Bright Field (BF) and several Dark Field (DF) detectors. For the experiment the detector was gradually offset from the axis and the signal from the central BF detector was studied as a function of the offset distance and compared with MC simulations. The experiment showed better agreement between experiment and several different MC simulations as compared to previous results, but differences were still found particularly for low angle scattering from Si. Data from Au suggest that high energy secondary electrons contribute to the signal on the central BF detector for low primary beam energies, when the STEM detector is in its usual central position.

  4. Simulations of radiation-damaged 3D detectors for the Super-LHC

    NASA Astrophysics Data System (ADS)

    Pennicard, D.; Pellegrini, G.; Fleta, C.; Bates, R.; O'Shea, V.; Parkes, C.; Tartoni, N.

    2008-07-01

    Future high-luminosity colliders, such as the Super-LHC at CERN, will require pixel detectors capable of withstanding extremely high radiation damage. In this article, the performances of various 3D detector structures are simulated with up to 1×1016 1 MeV- neq/cm2 radiation damage. The simulations show that 3D detectors have higher collection efficiency and lower depletion voltages than planar detectors due to their small electrode spacing. When designing a 3D detector with a large pixel size, such as an ATLAS sensor, different electrode column layouts are possible. Using a small number of n+ readout electrodes per pixel leads to higher depletion voltages and lower collection efficiency, due to the larger electrode spacing. Conversely, using more electrodes increases both the insensitive volume occupied by the electrode columns and the capacitive noise. Overall, the best performance after 1×1016 1 MeV- neq/cm2 damage is achieved by using 4-6 n+ electrodes per pixel.

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Graf, Norman A.; /SLAC

    Maximizing the physics performance of detectors being designed for the International Linear Collider, while remaining sensitive to cost constraints, requires a powerful, efficient, and flexible simulation, reconstruction and analysis environment to study the capabilities of a large number of different detector designs. The preparation of Letters Of Intent for the International Linear Collider involved the detailed study of dozens of detector options, layouts and readout technologies; the final physics benchmarking studies required the reconstruction and analysis of hundreds of millions of events. We describe the Java-based software toolkit (org.lcsim) which was used for full event reconstruction and analysis. The componentsmore » are fully modular and are available for tasks from digitization of tracking detector signals through to cluster finding, pattern recognition, track-fitting, calorimeter clustering, individual particle reconstruction, jet-finding, and analysis. The detector is defined by the same xml input files used for the detector response simulation, ensuring the simulation and reconstruction geometries are always commensurate by construction. We discuss the architecture as well as the performance.« less

  6. The AAO fiber instrument data simulator

    NASA Astrophysics Data System (ADS)

    Goodwin, Michael; Farrell, Tony; Smedley, Scott; Heald, Ron; Heijmans, Jeroen; De Silva, Gayandhi; Carollo, Daniela

    2012-09-01

    The fiber instrument data simulator is an in-house software tool that simulates detector images of fiber-fed spectrographs developed by the Australian Astronomical Observatory (AAO). In addition to helping validate the instrument designs, the resulting simulated images are used to develop the required data reduction software. Example applications that have benefited from the tool usage are the HERMES and SAMI instrumental projects for the Anglo-Australian Telescope (AAT). Given the sophistication of these projects an end-to-end data simulator that accurately models the predicted detector images is required. The data simulator encompasses all aspects of the transmission and optical aberrations of the light path: from the science object, through the atmosphere, telescope, fibers, spectrograph and finally the camera detectors. The simulator runs under a Linux environment that uses pre-calculated information derived from ZEMAX models and processed data from MATLAB. In this paper, we discuss the aspects of the model, software, example simulations and verification.

  7. Fast Simulation of Electromagnetic Showers in the ATLAS Calorimeter: Frozen Showers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barberio, E.; /Melbourne U.; Boudreau, J.

    2011-11-29

    One of the most time consuming process simulating pp interactions in the ATLAS detector at LHC is the simulation of electromagnetic showers in the calorimeter. In order to speed up the event simulation several parametrisation methods are available in ATLAS. In this paper we present a short description of a frozen shower technique, together with some recent benchmarks and comparison with full simulation. An expected high rate of proton-proton collisions in ATLAS detector at LHC requires large samples of simulated events (Monte Carlo) to study various physics processes. A detailed simulation of particle reactions ('full simulation') in the ATLAS detectormore » is based on GEANT4 and is very accurate. However, due to complexity of the detector, high particle multiplicity and GEANT4 itself, the average CPU time spend to simulate typical QCD event in pp collision is 20 or more minutes for modern computers. During detector simulation the largest time is spend in the calorimeters (up to 70%) most of which is required for electromagnetic particles in the electromagnetic (EM) part of the calorimeters. This is the motivation for fast simulation approaches which reduce the simulation time without affecting the accuracy. Several of fast simulation methods available within the ATLAS simulation framework (standard Athena based simulation program) are discussed here with the focus on the novel frozen shower library (FS) technique. The results obtained with FS are presented here as well.« less

  8. SU-C-201-02: Quantitative Small-Animal SPECT Without Scatter Correction Using High-Purity Germanium Detectors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gearhart, A; Peterson, T; Johnson, L

    2015-06-15

    Purpose: To evaluate the impact of the exceptional energy resolution of germanium detectors for preclinical SPECT in comparison to conventional detectors. Methods: A cylindrical water phantom was created in GATE with a spherical Tc-99m source in the center. Sixty-four projections over 360 degrees using a pinhole collimator were simulated. The same phantom was simulated using air instead of water to establish the true reconstructed voxel intensity without attenuation. Attenuation correction based on the Chang method was performed on MLEM reconstructed images from the water phantom to determine a quantitative measure of the effectiveness of the attenuation correction. Similarly, a NEMAmore » phantom was simulated, and the effectiveness of the attenuation correction was evaluated. Both simulations were carried out using both NaI detectors with an energy resolution of 10% FWHM and Ge detectors with an energy resolution of 1%. Results: Analysis shows that attenuation correction without scatter correction using germanium detectors can reconstruct a small spherical source to within 3.5%. Scatter analysis showed that for standard sized objects in a preclinical scanner, a NaI detector has a scatter-to-primary ratio between 7% and 12.5% compared to between 0.8% and 1.5% for a Ge detector. Preliminary results from line profiles through the NEMA phantom suggest that applying attenuation correction without scatter correction provides acceptable results for the Ge detectors but overestimates the phantom activity using NaI detectors. Due to the decreased scatter, we believe that the spillover ratio for the air and water cylinders in the NEMA phantom will be lower using germanium detectors compared to NaI detectors. Conclusion: This work indicates that the superior energy resolution of germanium detectors allows for less scattered photons to be included within the energy window compared to traditional SPECT detectors. This may allow for quantitative SPECT without implementing scatter correction, reducing uncertainties introduced by scatter correction algorithms. Funding provided by NIH/NIBIB grant R01EB013677; Todd Peterson, Ph.D., has had a research contract with PHDs Co., Knoxville, TN.« less

  9. Study of a new design of p-N semiconductor detector array for nuclear medicine imaging by monte carlo simulation codes.

    PubMed

    Hajizadeh-Safar, M; Ghorbani, M; Khoshkharam, S; Ashrafi, Z

    2014-07-01

    Gamma camera is an important apparatus in nuclear medicine imaging. Its detection part is consists of a scintillation detector with a heavy collimator. Substitution of semiconductor detectors instead of scintillator in these cameras has been effectively studied. In this study, it is aimed to introduce a new design of P-N semiconductor detector array for nuclear medicine imaging. A P-N semiconductor detector composed of N-SnO2 :F, and P-NiO:Li, has been introduced through simulating with MCNPX monte carlo codes. Its sensitivity with different factors such as thickness, dimension, and direction of emission photons were investigated. It is then used to configure a new design of an array in one-dimension and study its spatial resolution for nuclear medicine imaging. One-dimension array with 39 detectors was simulated to measure a predefined linear distribution of Tc(99_m) activity and its spatial resolution. The activity distribution was calculated from detector responses through mathematical linear optimization using LINPROG code on MATLAB software. Three different configurations of one-dimension detector array, horizontal, vertical one sided, and vertical double-sided were simulated. In all of these configurations, the energy windows of the photopeak were ± 1%. The results show that the detector response increases with an increase of dimension and thickness of the detector with the highest sensitivity for emission photons 15-30° above the surface. Horizontal configuration array of detectors is not suitable for imaging of line activity sources. The measured activity distribution with vertical configuration array, double-side detectors, has no similarity with emission sources and hence is not suitable for imaging purposes. Measured activity distribution using vertical configuration array, single side detectors has a good similarity with sources. Therefore, it could be introduced as a suitable configuration for nuclear medicine imaging. It has been shown that using semiconductor P-N detectors such as P-NiO:Li, N-SnO2 :F for gamma detection could be possibly applicable for design of a one dimension array configuration with suitable spatial resolution of 2.7 mm for nuclear medicine imaging.

  10. Recent developments in track reconstruction and hadron identification at MPD

    NASA Astrophysics Data System (ADS)

    Mudrokh, A.; Zinchenko, A.

    2017-03-01

    A Monte Carlo simulation of real detector effects with as many details as possible has been carried out instead of a simplified Geant point smearing approach during the study of the detector performance. Some results of realistic simulation of the MPD TPC (Time Projection Chamber) including digitization in central Au+Au collisions have been obtained. Particle identification (PID) has been tuned to account for modifications in the track reconstruction. Some results on hadron identification in the TPC and TOF (Time Of Flight) detectors with realistically simulated response have been also obtained.

  11. Organic Scintillator Detector Response Simulations with DRiFT

    DOE PAGES

    Andrews, Madison Theresa; Bates, Cameron Russell; Mckigney, Edward Allen; ...

    2016-06-11

    Here, this work presents the organic scintillation simulation capabilities of DRiFT, a post-processing Detector Response Function Toolkit for MCNPR output. DRiFT is used to create realistic scintillation detector response functions to incident neutron and gamma mixed- field radiation. As a post-processing tool, DRiFT leverages the extensively validated radiation transport capabilities of MCNPR ®6, which also provides the ability to simulate complex sources and geometries. DRiFT is designed to be flexible, it allows the user to specify scintillator material, PMT type, applied PMT voltage, and quenching data used in simulations. The toolkit's capabilities, which include the generation of pulse shape discriminationmore » plots and full-energy detector spectra, are demonstrated in a comparison of measured and simulated neutron contributions from 252Cf and PuBe, and photon spectra from 22Na and 228Th sources. DRiFT reproduced energy resolution effects observed in EJ-301 measurements through the inclusion of scintillation yield variances, photon transport noise, and PMT photocathode and multiplication noise.« less

  12. Monte-Carlo background simulations of present and future detectors in x-ray astronomy

    NASA Astrophysics Data System (ADS)

    Tenzer, C.; Kendziorra, E.; Santangelo, A.

    2008-07-01

    Reaching a low-level and well understood internal instrumental background is crucial for the scientific performance of an X-ray detector and, therefore, a main objective of the instrument designers. Monte-Carlo simulations of the physics processes and interactions taking place in a space-based X-ray detector as a result of its orbital environment can be applied to explain the measured background of existing missions. They are thus an excellent tool to predict and optimize the background of future observatories. Weak points of a design and the main sources of the background can be identified and methods to reduce them can be implemented and studied within the simulations. Using the Geant4 Monte-Carlo toolkit, we have created a simulation environment for space-based detectors and we present results of such background simulations for XMM-Newton's EPIC pn-CCD camera. The environment is also currently used to estimate and optimize the background of the future instruments Simbol-X and eRosita.

  13. Organic scintillator detector response simulations with DRiFT

    NASA Astrophysics Data System (ADS)

    Andrews, M. T.; Bates, C. R.; McKigney, E. A.; Solomon, C. J.; Sood, A.

    2016-09-01

    This work presents the organic scintillation simulation capabilities of DRiFT, a post-processing Detector Response Function Toolkit for MCNP® output. DRiFT is used to create realistic scintillation detector response functions to incident neutron and gamma mixed-field radiation. As a post-processing tool, DRiFT leverages the extensively validated radiation transport capabilities of MCNP® 6 , which also provides the ability to simulate complex sources and geometries. DRiFT is designed to be flexible, it allows the user to specify scintillator material, PMT type, applied PMT voltage, and quenching data used in simulations. The toolkit's capabilities, which include the generation of pulse shape discrimination plots and full-energy detector spectra, are demonstrated in a comparison of measured and simulated neutron contributions from 252Cf and PuBe, and photon spectra from 22Na and 228Th sources. DRiFT reproduced energy resolution effects observed in EJ-301 measurements through the inclusion of scintillation yield variances, photon transport noise, and PMT photocathode and multiplication noise.

  14. Impact of detector simulation in particle physics collider experiments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Elvira, V. Daniel

    Through the last three decades, precise simulation of the interactions of particles with matter and modeling of detector geometries has proven to be of critical importance to the success of the international high-energy physics experimental programs. For example, the detailed detector modeling and accurate physics of the Geant4-based simulation software of the CMS and ATLAS particle physics experiments at the European Center of Nuclear Research (CERN) Large Hadron Collider (LHC) was a determinant factor for these collaborations to deliver physics results of outstanding quality faster than any hadron collider experiment ever before. This review article highlights the impact of detectormore » simulation on particle physics collider experiments. It presents numerous examples of the use of simulation, from detector design and optimization, through software and computing development and testing, to cases where the use of simulation samples made a difference in the accuracy of the physics results and publication turnaround, from data-taking to submission. It also presents the economic impact and cost of simulation in the CMS experiment. Future experiments will collect orders of magnitude more data, taxing heavily the performance of simulation and reconstruction software for increasingly complex detectors. Consequently, it becomes urgent to find solutions to speed up simulation software in order to cope with the increased demand in a time of flat budgets. The study ends with a short discussion on the potential solutions that are being explored, by leveraging core count growth in multicore machines, using new generation coprocessors, and re-engineering of HEP code for concurrency and parallel computing.« less

  15. Impact of detector simulation in particle physics collider experiments

    DOE PAGES

    Elvira, V. Daniel

    2017-06-01

    Through the last three decades, precise simulation of the interactions of particles with matter and modeling of detector geometries has proven to be of critical importance to the success of the international high-energy physics experimental programs. For example, the detailed detector modeling and accurate physics of the Geant4-based simulation software of the CMS and ATLAS particle physics experiments at the European Center of Nuclear Research (CERN) Large Hadron Collider (LHC) was a determinant factor for these collaborations to deliver physics results of outstanding quality faster than any hadron collider experiment ever before. This review article highlights the impact of detectormore » simulation on particle physics collider experiments. It presents numerous examples of the use of simulation, from detector design and optimization, through software and computing development and testing, to cases where the use of simulation samples made a difference in the accuracy of the physics results and publication turnaround, from data-taking to submission. It also presents the economic impact and cost of simulation in the CMS experiment. Future experiments will collect orders of magnitude more data, taxing heavily the performance of simulation and reconstruction software for increasingly complex detectors. Consequently, it becomes urgent to find solutions to speed up simulation software in order to cope with the increased demand in a time of flat budgets. The study ends with a short discussion on the potential solutions that are being explored, by leveraging core count growth in multicore machines, using new generation coprocessors, and re-engineering of HEP code for concurrency and parallel computing.« less

  16. Effect of electron transport properties on unipolar CdZnTe radiation detectors: LUND, SpectrumPlus, and Coplanar Grid

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ralph B. James

    2000-01-07

    Device simulations of (1) the laterally-contacted-unipolar-nuclear detector (LUND), (2) the SpectrumPlus, (3) and the coplanar grid made of Cd{sub 0.9}Zn{sub 0.1}Te (CZT) were performed for {sup 137}Cs irradiation by 662.15 keV gamma-rays. Realistic and controlled simulations of the gamma-ray interactions with the CZT material were done using the MCNP4B2 Monte Carlo program, and the detector responses were simulated using the Sandia three-dimensional multielectrode simulation program (SandTMSP). The simulations were done for the best and the worst expected carrier nobilities and lifetimes of currently commercially available CZT materials for radiation detector applications. For the simulated unipolar devices, the active device volumesmore » were relatively large and the energy resolutions were fairly good, but these performance characteristics were found to be very sensitive to the materials properties. The internal electric fields, the weighting potentials, and the charge induced efficiency maps were calculated to give insights into the operation of these devices.« less

  17. Simulating the Response of a New Beta Delayed Proton Detector

    NASA Astrophysics Data System (ADS)

    Roosa, Michael; Friedman, Moshe; Wrede, Christopher

    2017-09-01

    To better understand reactions of astrophysical importance, such as 15O(α, γ)19Ne and 30P(p, γ)31S, a new gas filled detector of β-delayed charged particles has been designed and built for use at the National Superconducting Cyclotron Laboratory. The detector has separate drift and proportional amplification regions provided by a flex-board field cage and a Micromegas structure, respectively. We have developed a simulation to model the response of this detector using Magboltz and Garfield++ which calculate the electron transport and amplification through the two regions. The simulation provides information that is useful for understanding the microscopic function of the detector and will help optimize its operation. This work is supported by the U.S. National Science Foundation under Award Nos. PHY-1102511 and PHY- 1565546 and the U.S. Department of Energy, Office of Science, under Award No. DE-SC0016052.

  18. Monte Carlo simulation of a photodisintegration of 3 H experiment in Geant4

    NASA Astrophysics Data System (ADS)

    Gray, Isaiah

    2013-10-01

    An upcoming experiment involving photodisintegration of 3 H at the High Intensity Gamma-Ray Source facility at Duke University has been simulated in the software package Geant4. CAD models of silicon detectors and wire chambers were imported from Autodesk Inventor using the program FastRad and the Geant4 GDML importer. Sensitive detectors were associated with the appropriate logical volumes in the exported GDML file so that changes in detector geometry will be easily manifested in the simulation. Probability distribution functions for the energy and direction of outgoing protons were generated using numerical tables from previous theory, and energies and directions were sampled from these distributions using a rejection sampling algorithm. The simulation will be a useful tool to optimize detector geometry, estimate background rates, and test data analysis algorithms. This work was supported by the Triangle Universities Nuclear Laboratory REU program at Duke University.

  19. Activation of QA devices and phantom materials under clinical scanning proton beams—a gamma spectrometry study

    NASA Astrophysics Data System (ADS)

    Hanušová, Tereza; Johnová, Kamila; Navrátil, Matěj; Valenta, Jiří; Müller, Lutz

    2018-06-01

    Activation of detectors and phantoms used for commissioning and quality assurance of clinical proton beams may lead to radiation protection issues. Good understanding of the activation nuclide vectors involved is necessary to assess radiation risk for the personnel working with these devices on a daily basis or to fulfill legal requirements regarding transport of radioactive material and its release to the public. 11 devices and material samples were irradiated with a 220 MeV proton pencil beam (PBS, Proton Therapy Center, Prague). This study focuses on devices manufactured by IBA Dosimetry GmbH: MatriXX PT, PPC05, Stingray, Zebra, Lynx, a Blue Phantom rail and samples of RW3, PMMA, titanium, copper and carbon fibre plastic. Monitor units (MU) were monitored during delivery. Gamma spectrometry was then performed for each item using a HPGe detector, with a focus on longer lived gamma emitting radionuclides. Activities were quantified for all found isotopes and compared to relevant legal limits for exemption and clearance of radioactive objects. Activation was found to be significant after long irradiation sessions, as done during commissioning of a proton therapy room. Some of the investigated devices may also cumulate activity in time, depending on the scenario of periodic irradiation in routine clinical practice. However, the levels of activity and resulting beta/gamma doses are more comparable to internationally recommended concentration limits for exemption than to dose limits for radiation workers. Results of this study will help to determine nuclide inventories required by some legal authorities for radiation protection purposes.

  20. Anthropic influences on the sedimentation rates of lakes situated in different geographic areas.

    PubMed

    Simon, Hedvig; Kelemen, Szabolcs; Begy, Róbert-Csaba

    2017-07-01

    The aim of this study is to determine the effects of natural and anthropic events occurring in the last 30 years in the catchment areas of four Romanian lakes (St. Anna Lake, Red Lake, Vârşolţ Lake and Matiţa Lake) originating from four different geomorphologic areas. A total of eleven sediment cores have been processed for age and sedimentation rate determination using the 210 Pb dating method. Total 210 Pb was measured via alpha spectrometry by 210 Po using PIPS detectors, while supported 210 Pb was measured by 226 Ra using HPGe detectors. Ages and sedimentation rates were calculated using the CRS model. The values of the sedimentation rates have grown multiply in the last three decades: 2.66 times in case of the St. Anna Lake (from 0.06 ± 0.01 g/cm 2 y to 0.16 ± 0.02 g/cm 2 y), up to 6.72 times in case of Red Lake (0.36 ± 0.04 g/cm 2 y to 2.42 ± 0.36 g/cm 2 y), 4.02 times in case of Vârşolţ Lake (04 g/cm 2 y to 1.53 ± 0.18 g/cm 2 y) and up to 16.18 times in case of Matiţa Lake (0.27 ± 0.03 g/cm 2 y to 4.37 ± 0.32). Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. Activation of QA devices and phantom materials under clinical scanning proton beams-a gamma spectrometry study.

    PubMed

    Hanušová, Tereza; Johnová, Kamila; Navrátil, Matěj; Valenta, Jiří; Müller, Lutz

    2018-06-07

    Activation of detectors and phantoms used for commissioning and quality assurance of clinical proton beams may lead to radiation protection issues. Good understanding of the activation nuclide vectors involved is necessary to assess radiation risk for the personnel working with these devices on a daily basis or to fulfill legal requirements regarding transport of radioactive material and its release to the public. 11 devices and material samples were irradiated with a 220 MeV proton pencil beam (PBS, Proton Therapy Center, Prague). This study focuses on devices manufactured by IBA Dosimetry GmbH: MatriXX PT, PPC05, Stingray, Zebra, Lynx, a Blue Phantom rail and samples of RW3, PMMA, titanium, copper and carbon fibre plastic. Monitor units (MU) were monitored during delivery. Gamma spectrometry was then performed for each item using a HPGe detector, with a focus on longer lived gamma emitting radionuclides. Activities were quantified for all found isotopes and compared to relevant legal limits for exemption and clearance of radioactive objects. Activation was found to be significant after long irradiation sessions, as done during commissioning of a proton therapy room. Some of the investigated devices may also cumulate activity in time, depending on the scenario of periodic irradiation in routine clinical practice. However, the levels of activity and resulting beta/gamma doses are more comparable to internationally recommended concentration limits for exemption than to dose limits for radiation workers. Results of this study will help to determine nuclide inventories required by some legal authorities for radiation protection purposes.

  2. Detection of explosive substances by tomographic inspection using neutron and gamma-ray spectroscopy

    NASA Astrophysics Data System (ADS)

    Farahmand, M.; Boston, A. J.; Grint, A. N.; Nolan, P. J.; Joyce, M. J.; Mackin, R. O.; D'Mellow, B.; Aspinall, M.; Peyton, A. J.; van Silfhout, R.

    2007-08-01

    In recent years the detection and identification of hazardous materials has become increasingly important. This work discusses research and development of a technique which is capable of detecting and imaging hidden explosives. It is proposed to utilise neutron interrogation of the substances under investigation facilitating the detection of emitted gamma radiation and scattered neutrons. Pulsed fast neutron techniques are attractive because they can be used to determine the concentrations of the light elements (hydrogen, carbon, nitrogen, and oxygen) which can be the primary components of explosive materials. Using segmented High Purity Ge (HPGe) detectors and digital pulse processing [R.J. Cooper, G. Turk, A.J. Boston, H.C. Boston, J.R. Cresswell, A.R. Mather, P.J. Nolan, C.J. Hall, I. Lazarus, J. Simpson, A. Berry, T. Beveridge, J. Gillam, R.A. Lewis, in: Proceedings of the 7th International Conference on Position Sensitive Detectors, Nuclear Instruments and Methods A, in press; I. Lazarus, D.E. Appelbe, A. J. Boston, P.J. Coleman-Smith, J.R. Cresswell, M. Descovich, S.A.A. Gros, M. Lauer, J. Norman, C.J. Pearson, V.F.E. Pucknell, J.A. Sampson, G. Turk, J.J. Valiente-Dobón, IEEE Trans. Nucl. Sci., 51 (2004) 1353; R.J. Cooper, A.J. Boston, H.C. Boston, J.R. Cresswell, A.N. Grint, A.R. Mather, P.J. Nolan, D.P. Scraggs, G. Turk, C.J. Hall, I. Lazarus, A. Berry, T. Beveridge, J. Gillam, R.A. Lewis, in: Proceedings of the 11th International Symposium on Radiation Measurements and Application, 2006. [1-3

  3. Radiation hazard indices of soil and water samples in Northern Malaysian Peninsula.

    PubMed

    Almayahi, B A; Tajuddin, A A; Jaafar, M S

    2012-11-01

    The radioactivity quantity and quality were determined in soil and water samples in Northern Malaysian Peninsula (NMP) using HPGe spectroscopy and GR-135 spectrometer. The (226)Ra, (232)Th and (40)K concentrations in soil samples are 57±2, 68±4 and 427±17 Bq kg(-1), respectively, whereas in water samples were found to be 2.86±0.79, 3.78±1.73 and 152±12 Bq l(-1), respectively. These concentrations are within those reported from literature in other countries in the world. The radiological hazard indices of the samples were also calculated. The mean values obtained from soil samples are 186 Bq kg(-1), 88 nGy h(-1), 108 μSv y(-1), 0.50 and 0.65 for Radium Equivalent Activity (Ra(eq)), Absorbed Dose Rates (D(R)), Annual Effective Dose Rates (ED), External Hazard Index (H(ex)) and Internal Hazard Index (H(in)) respectively, whereas, for water samples were found to be 20, 10, 13, 0.05 and 0.06, respectively. All the health hazard indices are well below their recommended limits, except in two soil sampling sites which were found to be (*)025 (1.1 H(ex)) and (*)026 (1.1 H(ex), 1.6 H(in)). The calculated and the measured gamma dose rates had a good correlation coefficient, R=0.88. Moreover, the average value radon is 20 (in the range of 7-64) Bq m(-3), a positive correlation (R=0.81) was observed between the (222)Rn and (226)Ra concentrations in samples measured by the SNC continuous radon monitor (model 1029, Sun Nuclear Corporation) and HPGe detector, respectively. Some soils in this study with H(in) and H(ex)<1 are suitable for use in agriculture and as building materials. Also, in this study H(in) and H(ex)<1 for water samples, therefore, water after processing and filtration is safe and suitable for use in household and industrial purposes. Copyright © 2012 Elsevier Ltd. All rights reserved.

  4. Abstract ID: 242 Simulation of a Fast Timing Micro-Pattern Gaseous Detector for TOF-PET.

    PubMed

    Radogna, Raffaella; Verwilligen, Piet

    2018-01-01

    Micro-Pattern Gas Detectors (MPGDs) are a new generation of gaseous detectors that have been developed thanks to advances in micro-structure technology. The main features of the MPGDs are: high rate capability (>50 MHz/cm 2 ); excellent spatial resolution (down to 50 μm); good time resolution (down to 3 ns); reduced radiation length, affordable costs, and possible flexible geometries. A new detector layout has been recently proposed that aims at combining both the high spatial resolution and high rate capability (100 MHz/cm 2 ) of the current state-of-the-art MPGDs with a high time resolution. This new type of MPGD is named the Fast Timing MPGD (FTM) detector [1,2]. The FTM developed for detecting charged particles can potentially reach sub-millimeter spatial resolution and 100 ps time resolution. This contribution introduces a Fast Timing MPGD technology optimized to detect photons, as an innovative PET imaging detector concept and emphases the importance of full detector simulation to guide the design of the detector geometry. The design and development of a new FTM, combining excellent time and spatial resolution, while exploiting the advantages of a reasonable energy resolution, will be a boost for the design of affordable TOF-PET scanner with improved image contrast. The use of such an affordable gas detector allows to instrument large areas in a cost-effective way, and to increase in image contrast for shorter scanning times (lowering the risk for the patient) and better diagnosis of the disease. In this report a dedicated simulation study is performed to optimize the detector design in the contest of the INFN project MPGD-Fatima. Results are obtained with ANSYS, COMSOL, GARFIELD++ and GEANT4 simulation tools. The final detector layout will be trade-off between fast time and good energy resolution. Copyright © 2017.

  5. Improved image quality using monolithic scintillator detectors with dual-sided readout in a whole-body TOF-PET ring: a simulation study.

    PubMed

    Tabacchini, Valerio; Surti, Suleman; Borghi, Giacomo; Karp, Joel S; Schaart, Dennis R

    2017-02-13

    We have recently built and characterized the performance of a monolithic scintillator detector based on a 32 mm  ×  32 mm  ×  22 mm LYSO:Ce crystal read out by digital silicon photomultiplier (dSiPM) arrays coupled to the crystal front and back surfaces in a dual-sided readout (DSR) configuration. The detector spatial resolution appeared to be markedly better than that of a detector consisting of the same crystal with conventional back-sided readout (BSR). Here, we aim to evaluate the influence of this difference in the detector spatial response on the quality of reconstructed images, so as to quantify the potential benefit of the DSR approach for high-resolution, whole-body time-of-flight (TOF) positron emission tomography (PET) applications. We perform Monte Carlo simulations of clinical PET systems based on BSR and DSR detectors, using the results of our detector characterization experiments to model the detector spatial responses. We subsequently quantify the improvement in image quality obtained with DSR compared to BSR, using clinically relevant metrics such as the contrast recovery coefficient (CRC) and the area under the localized receiver operating characteristic curve (ALROC). Finally, we compare the results with simulated rings of pixelated detectors with DOI capability. Our results show that the DSR detector produces significantly higher CRC and increased ALROC values than the BSR detector. The comparison with pixelated systems indicates that one would need to choose a crystal size of 3.2 mm with three DOI layers to match the performance of the BSR detector, while a pixel size of 1.3 mm with three DOI layers would be required to get on par with the DSR detector.

  6. Improved image quality using monolithic scintillator detectors with dual-sided readout in a whole-body TOF-PET ring: a simulation study

    NASA Astrophysics Data System (ADS)

    Tabacchini, Valerio; Surti, Suleman; Borghi, Giacomo; Karp, Joel S.; Schaart, Dennis R.

    2017-03-01

    We have recently built and characterized the performance of a monolithic scintillator detector based on a 32 mm  ×  32 mm  ×  22 mm LYSO:Ce crystal read out by digital silicon photomultiplier (dSiPM) arrays coupled to the crystal front and back surfaces in a dual-sided readout (DSR) configuration. The detector spatial resolution appeared to be markedly better than that of a detector consisting of the same crystal with conventional back-sided readout (BSR). Here, we aim to evaluate the influence of this difference in the detector spatial response on the quality of reconstructed images, so as to quantify the potential benefit of the DSR approach for high-resolution, whole-body time-of-flight (TOF) positron emission tomography (PET) applications. We perform Monte Carlo simulations of clinical PET systems based on BSR and DSR detectors, using the results of our detector characterization experiments to model the detector spatial responses. We subsequently quantify the improvement in image quality obtained with DSR compared to BSR, using clinically relevant metrics such as the contrast recovery coefficient (CRC) and the area under the localized receiver operating characteristic curve (ALROC). Finally, we compare the results with simulated rings of pixelated detectors with DOI capability. Our results show that the DSR detector produces significantly higher CRC and increased ALROC values than the BSR detector. The comparison with pixelated systems indicates that one would need to choose a crystal size of 3.2 mm with three DOI layers to match the performance of the BSR detector, while a pixel size of 1.3 mm with three DOI layers would be required to get on par with the DSR detector.

  7. Analytical modeling and numerical simulation of the short-wave infrared electron-injection detectors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Movassaghi, Yashar; Fathipour, Morteza; Fathipour, Vala

    2016-03-21

    This paper describes comprehensive analytical and simulation models for the design and optimization of the electron-injection based detectors. The electron-injection detectors evaluated here operate in the short-wave infrared range and utilize a type-II band alignment in InP/GaAsSb/InGaAs material system. The unique geometry of detectors along with an inherent negative-feedback mechanism in the device allows for achieving high internal avalanche-free amplifications without any excess noise. Physics-based closed-form analytical models are derived for the detector rise time and dark current. Our optical gain model takes into account the drop in the optical gain at high optical power levels. Furthermore, numerical simulation studiesmore » of the electrical characteristics of the device show good agreement with our analytical models as well experimental data. Performance comparison between devices with different injector sizes shows that enhancement in the gain and speed is anticipated by reducing the injector size. Sensitivity analysis for the key detector parameters shows the relative importance of each parameter. The results of this study may provide useful information and guidelines for development of future electron-injection based detectors as well as other heterojunction photodetectors.« less

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cho, H; Ding, H; Ziemer, B

    Purpose: To investigate the feasibility of energy calibration and energy response characterization of a photon counting detector using x-ray fluorescence. Methods: A comprehensive Monte Carlo simulation study was done to investigate the influence of various geometric components on the x-ray fluorescence measurement. Different materials, sizes, and detection angles were simulated using Geant4 Application for Tomographic Emission (GATE) Monte Carlo package. Simulations were conducted using 100 kVp tungsten-anode spectra with 2 mm Al filter for a single pixel cadmium telluride (CdTe) detector with 3 × 3 mm2 in detection area. The fluorescence material was placed 300 mm away from both themore » x-ray source and the detector. For angular dependence measurement, the distance was decreased to 30 mm to reduce the simulation time. Compound materials, containing silver, barium, gadolinium, hafnium, and gold in cylindrical shape, were simulated. The object size varied from 5 to 100 mm in diameter. The angular dependence of fluorescence and scatter were simulated from 20° to 170° with an incremental step of 10° to optimize the fluorescence to scatter ratio. Furthermore, the angular dependence was also experimentally measured using a spectrometer (X-123CdTe, Amptek Inc., MA) to validate the simulation results. Results: The detection angle between 120° to 160° resulted in more optimal x-ray fluorescence to scatter ratio. At a detection angle of 120°, the object size did not have a significant effect on the fluorescence to scatter ratio. The experimental results of fluorescence angular dependence are in good agreement with the simulation results. The Kα and Kβ peaks of five materials could be identified. Conclusion: The simulation results show that the x-ray fluorescence procedure has the potential to be used for detector energy calibration and detector response characteristics by using the optimal system geometry.« less

  9. Designing a new type of neutron detector for neutron and gamma-ray discrimination via GEANT4.

    PubMed

    Shan, Qing; Chu, Shengnan; Ling, Yongsheng; Cai, Pingkun; Jia, Wenbao

    2016-04-01

    Design of a new type of neutron detector, consisting of a fast neutron converter, plastic scintillator, and Cherenkov detector, to discriminate 14-MeV fast neutrons and gamma rays in a pulsed n-γ mixed field and monitor their neutron fluxes is reported in this study. Both neutrons and gamma rays can produce fluorescence in the scintillator when they are incident on the detector. However, only the secondary charged particles of the gamma rays can produce Cherenkov light in the Cherenkov detector. The neutron and gamma-ray fluxes can be calculated by measuring the fluorescence and Cherenkov light. The GEANT4 Monte Carlo simulation toolkit is used to simulate the whole process occurring in the detector, whose optimum parameters are known. Analysis of the simulation results leads to a calculation method of neutron flux. This method is verified by calculating the neutron fluxes using pulsed n-γ mixed fields with different n/γ ratios, and the results show that the relative errors of all calculations are <5%. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. FastSim: A Fast Simulation for the SuperB Detector

    NASA Astrophysics Data System (ADS)

    Andreassen, R.; Arnaud, N.; Brown, D. N.; Burmistrov, L.; Carlson, J.; Cheng, C.-h.; Di Simone, A.; Gaponenko, I.; Manoni, E.; Perez, A.; Rama, M.; Roberts, D.; Rotondo, M.; Simi, G.; Sokoloff, M.; Suzuki, A.; Walsh, J.

    2011-12-01

    We have developed a parameterized (fast) simulation for detector optimization and physics reach studies of the proposed SuperB Flavor Factory in Italy. Detector components are modeled as thin sections of planes, cylinders, disks or cones. Particle-material interactions are modeled using simplified cross-sections and formulas. Active detectors are modeled using parameterized response functions. Geometry and response parameters are configured using xml files with a custom-designed schema. Reconstruction algorithms adapted from BaBar are used to build tracks and clusters. Multiple sources of background signals can be merged with primary signals. Pattern recognition errors are modeled statistically by randomly misassigning nearby tracking hits. Standard BaBar analysis tuples are used as an event output. Hadronic B meson pair events can be simulated at roughly 10Hz.

  11. Representing Misalignments of the STAR Geometry Model using AgML

    NASA Astrophysics Data System (ADS)

    Webb, Jason C.; Lauret, Jérôme; Perevotchikov, Victor; Smirnov, Dmitri; Van Buren, Gene

    2017-10-01

    The STAR Heavy Flavor Tracker (HFT) was designed to provide high-precision tracking for the identification of charmed hadron decays in heavy-ion collisions at RHIC. It consists of three independently mounted subsystems, providing four precision measurements along the track trajectory, with the goal of pointing decay daughters back to vertices displaced by less than 100 microns from the primary event vertex. The ultimate efficiency and resolution of the physics analysis will be driven by the quality of the simulation and reconstruction of events in heavy-ion collisions. In particular, it is important that the geometry model properly accounts for the relative misalignments of the HFT subsystems, along with the alignment of the HFT relative to STARs primary tracking detector, the Time Projection Chamber (TPC). The Abstract Geometry Modeling Language (AgML) provides a single description of the STAR geometry, generating both our simulation (GEANT 3) and reconstruction geometries (ROOT). AgML implements an ideal detector model, while misalignments are stored separately in database tables. These have historically been applied at the hit level. Simulated detector hits are projected from their ideal position along the track’s trajectory, until they intersect the misaligned detector volume, where the struck detector element is calculated for hit digitization. This scheme has worked well as hit errors have been negligible compared with the size of sensitive volumes. The precision and complexity of the HFT detector require us to apply misalignments to the detector volumes themselves. In this paper we summarize the extension of the AgML language and support libraries to enable the static misalignment of our reconstruction and simulation geometries, discussing the design goals, limitations and path to full misalignment support in ROOT/VMC-based simulation.

  12. Performance Evaluation of Spectroscopic Detectors for LEU Hold-up Measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Venkataraman, Ramkumar; Nutter, Greg; McElroy, Robert Dennis

    The hold-up measurement of low-enriched uranium materials may require use of alternate detector types relative to the measurement of highly enriched uranium. This is in part due to the difference in process scale (i.e., the components are generally larger for low-enriched uranium systems), but also because the characteristic gamma-ray lines from 235U used for assay of highly enriched uranium will be present at a much reduced intensity (on a per gram of uranium basis) at lower enrichments. Researchers at Oak Ridge National Laboratory examined the performance of several standard detector types, e.g., NaI(Tl), LaBr3(Ce), and HPGe, to select a suitablemore » candidate for measuring and quantifying low-enriched uranium hold-up in process pipes and equipment at the Portsmouth gaseous diffusion plant. Detector characteristics, such as energy resolution (full width at half maximum) and net peak count rates at gamma ray energies spanning a range of 60–1332 keV, were measured for the above-mentioned detector types using the same sources and in the same geometry. Uranium enrichment standards (Certified Reference Material no. 969 and Certified Reference Material no. 146) were measured using each of the detector candidates in the same geometry. The net count rates recorded by each detector at 186 keV and 1,001 keV were plotted as a function of enrichment (atom percentage). Background measurements were made in unshielded and shielded configurations under both ambient and elevated conditions of 238U activity. The highly enriched uranium hold-up measurement campaign at the Portsmouth plant was performed on process equipment that had been cleaned out. Therefore, in most cases, the thickness of the uranium deposits was less than the “infinite thickness” for the 186 keV gamma rays to be completely self-attenuated. Because of this, in addition to measuring the 186 keV gamma, the 1,001 keV gamma ray from 234mPa—a daughter of 238U in secular equilibrium with its parent—will also need to be measured. Based on the performance criteria of detection efficiency, energy resolution, peak-to-continuum ratios, minimum detectable limits, and the weight of the shielded probe, a shielded (0.5 in. thick lead shield) 2 × 2 in. NaI(Tl) detector is recommended for use. The recommended approach is to carry out analysis using data from both 186 keV and 1,001 keV gamma rays, and select a best result based on propagated uncertainty estimates. It is also highly recommended that a two-point gain stabilization scheme based on an 241Am seed embedded in the probe be implemented. Shielding configurations to reduce the impact of background interference on the measurement of 1,001 keV gamma-ray are discussed.« less

  13. What are the assets and weaknesses of HFO detectors? A benchmark framework based on realistic simulations

    PubMed Central

    Pizzo, Francesca; Bartolomei, Fabrice; Wendling, Fabrice; Bénar, Christian-George

    2017-01-01

    High-frequency oscillations (HFO) have been suggested as biomarkers of epileptic tissues. While visual marking of these short and small oscillations is tedious and time-consuming, automatic HFO detectors have not yet met a large consensus. Even though detectors have been shown to perform well when validated against visual marking, the large number of false detections due to their lack of robustness hinder their clinical application. In this study, we developed a validation framework based on realistic and controlled simulations to quantify precisely the assets and weaknesses of current detectors. We constructed a dictionary of synthesized elements—HFOs and epileptic spikes—from different patients and brain areas by extracting these elements from the original data using discrete wavelet transform coefficients. These elements were then added to their corresponding simulated background activity (preserving patient- and region- specific spectra). We tested five existing detectors against this benchmark. Compared to other studies confronting detectors, we did not only ranked them according their performance but we investigated the reasons leading to these results. Our simulations, thanks to their realism and their variability, enabled us to highlight unreported issues of current detectors: (1) the lack of robust estimation of the background activity, (2) the underestimated impact of the 1/f spectrum, and (3) the inadequate criteria defining an HFO. We believe that our benchmark framework could be a valuable tool to translate HFOs into a clinical environment. PMID:28406919

  14. A machine learning method for fast and accurate characterization of depth-of-interaction gamma cameras

    NASA Astrophysics Data System (ADS)

    Pedemonte, Stefano; Pierce, Larry; Van Leemput, Koen

    2017-11-01

    Measuring the depth-of-interaction (DOI) of gamma photons enables increasing the resolution of emission imaging systems. Several design variants of DOI-sensitive detectors have been recently introduced to improve the performance of scanners for positron emission tomography (PET). However, the accurate characterization of the response of DOI detectors, necessary to accurately measure the DOI, remains an unsolved problem. Numerical simulations are, at the state of the art, imprecise, while measuring directly the characteristics of DOI detectors experimentally is hindered by the impossibility to impose the depth-of-interaction in an experimental set-up. In this article we introduce a machine learning approach for extracting accurate forward models of gamma imaging devices from simple pencil-beam measurements, using a nonlinear dimensionality reduction technique in combination with a finite mixture model. The method is purely data-driven, not requiring simulations, and is applicable to a wide range of detector types. The proposed method was evaluated both in a simulation study and with data acquired using a monolithic gamma camera designed for PET (the cMiCE detector), demonstrating the accurate recovery of the DOI characteristics. The combination of the proposed calibration technique with maximum- a posteriori estimation of the coordinates of interaction provided a depth resolution of  ≈1.14 mm for the simulated PET detector and  ≈1.74 mm for the cMiCE detector. The software and experimental data are made available at http://occiput.mgh.harvard.edu/depthembedding/.

  15. Lead foil wrapping of the plastic scintillators for the gamma ray detection: optical reflector or spectrum intensifier?

    NASA Astrophysics Data System (ADS)

    Taheri, A.; Askari, M.; Taghan Sasanpour, M.

    2017-08-01

    This paper studies the effect of lead wrapping on the response of the plastic scintillators as gamma detectors. Experimental tests and Geant4 simulations showed that lead wrapping cannot increase the gamma absorption efficiency of the detector but, as a reflector, it can improve the optical properties of the detector. The reflectivity of the lead foil as an optical reflector was determined equal to 66% using an experimental-simulation combined method. Based on the obtained results, the optical collection efficiency of the detector was also increased about 4% after employing the lead reflector.

  16. Simulation and Measurement of Absorbed Dose from 137 Cs Gammas Using a Si Timepix Detector

    NASA Technical Reports Server (NTRS)

    Stoffle, Nicholas; Pinsky, Lawrence; Empl, Anton; Semones, Edward

    2011-01-01

    The TimePix readout chip is a hybrid pixel detector with over 65k independent pixel elements. Each pixel contains its own circuitry for charge collection, counting logic, and readout. When coupled with a Silicon detector layer, the Timepix chip is capable of measuring the charge, and thus energy, deposited in the Silicon. Measurements using a NIST traceable 137Cs gamma source have been made at Johnson Space Center using such a Si Timepix detector, and this data is compared to simulations of energy deposition in the Si layer carried out using FLUKA.

  17. Investigating the response of Micromegas detector to low-energy neutrons using Monte Carlo simulation

    NASA Astrophysics Data System (ADS)

    Khezripour, S.; Negarestani, A.; Rezaie, M. R.

    2017-08-01

    Micromegas detector has recently been used for high-energy neutron (HEN) detection, but the aim of this research is to investigate the response of the Micromegas detector to low-energy neutron (LEN). For this purpose, a Micromegas detector (with air, P10, BF3, 3He and Ar/BF3 mixture) was optimized for the detection of 60 keV neutrons using the MCNP (Monte Carlo N Particle) code. The simulation results show that the optimum thickness of the cathode is 1 mm and the optimum of microgrid location is 100 μm above the anode. The output current of this detector for Ar (3%) + BF3 (97%) mixture is greater than the other ones. This mixture is considered as the appropriate gas for the Micromegas neutron detector providing the output current for 60 keV neutrons at the level of 97.8 nA per neutron. Consecuently, this detector can be introduced as LEN detector.

  18. Simulating the x-ray image contrast to setup techniques with desired flaw detectability

    NASA Astrophysics Data System (ADS)

    Koshti, Ajay M.

    2015-04-01

    The paper provides simulation data of previous work by the author in developing a model for estimating detectability of crack-like flaws in radiography. The methodology is developed to help in implementation of NASA Special x-ray radiography qualification, but is generically applicable to radiography. The paper describes a method for characterizing the detector resolution. Applicability of ASTM E 2737 resolution requirements to the model are also discussed. The paper describes a model for simulating the detector resolution. A computer calculator application, discussed here, also performs predicted contrast and signal-to-noise ratio calculations. Results of various simulation runs in calculating x-ray flaw size parameter and image contrast for varying input parameters such as crack depth, crack width, part thickness, x-ray angle, part-to-detector distance, part-to-source distance, source sizes, and detector sensitivity and resolution are given as 3D surfaces. These results demonstrate effect of the input parameters on the flaw size parameter and the simulated image contrast of the crack. These simulations demonstrate utility of the flaw size parameter model in setting up x-ray techniques that provide desired flaw detectability in radiography. The method is applicable to film radiography, computed radiography, and digital radiography.

  19. Gamma-Ray Simulated Spectrum Deconvolution of a LaBr₃ 1-in. x 1-in. Scintillator for Nondestructive ATR Fuel Burnup On-Site Predictions

    DOE PAGES

    Navarro, Jorge; Ring, Terry A.; Nigg, David W.

    2015-03-01

    A deconvolution method for a LaBr₃ 1"x1" detector for nondestructive Advanced Test Reactor (ATR) fuel burnup applications was developed. The method consisted of obtaining the detector response function, applying a deconvolution algorithm to 1”x1” LaBr₃ simulated, data along with evaluating the effects that deconvolution have on nondestructively determining ATR fuel burnup. The simulated response function of the detector was obtained using MCNPX as well with experimental data. The Maximum-Likelihood Expectation Maximization (MLEM) deconvolution algorithm was selected to enhance one-isotope source-simulated and fuel- simulated spectra. The final evaluation of the study consisted of measuring the performance of the fuel burnup calibrationmore » curve for the convoluted and deconvoluted cases. The methodology was developed in order to help design a reliable, high resolution, rugged and robust detection system for the ATR fuel canal capable of collecting high performance data for model validation, along with a system that can calculate burnup and using experimental scintillator detector data.« less

  20. A scintillator-based approach to monitor secondary neutron production during proton therapy.

    PubMed

    Clarke, S D; Pryser, E; Wieger, B M; Pozzi, S A; Haelg, R A; Bashkirov, V A; Schulte, R W

    2016-11-01

    The primary objective of this work is to measure the secondary neutron field produced by an uncollimated proton pencil beam impinging on different tissue-equivalent phantom materials using organic scintillation detectors. Additionally, the Monte Carlo code mcnpx-PoliMi was used to simulate the detector response for comparison to the measured data. Comparison of the measured and simulated data will validate this approach for monitoring secondary neutron dose during proton therapy. Proton beams of 155- and 200-MeV were used to irradiate a variety of phantom materials and secondary particles were detected using organic liquid scintillators. These detectors are sensitive to fast neutrons and gamma rays: pulse shape discrimination was used to classify each detected pulse as either a neutron or a gamma ray. The mcnpx-PoliMi code was used to simulate the secondary neutron field produced during proton irradiation of the same tissue-equivalent phantom materials. An experiment was performed at the Loma Linda University Medical Center proton therapy research beam line and corresponding models were created using the mcnpx-PoliMi code. The authors' analysis showed agreement between the simulations and the measurements. The simulated detector response can be used to validate the simulations of neutron and gamma doses on a particular beam line with or without a phantom. The authors have demonstrated a method of monitoring the neutron component of the secondary radiation field produced by therapeutic protons. The method relies on direct detection of secondary neutrons and gamma rays using organic scintillation detectors. These detectors are sensitive over the full range of biologically relevant neutron energies above 0.5 MeV and allow effective discrimination between neutron and photon dose. Because the detector system is portable, the described system could be used in the future to evaluate secondary neutron and gamma doses on various clinical beam lines for commissioning and prospective data collection in pediatric patients treated with proton therapy.

  1. Simulation of energy spectrum of GEM detector from an x-ray quantum

    NASA Astrophysics Data System (ADS)

    Malinowski, K.; Chernyshova, M.; Czarski, T.; Kowalska-Strzęciwilk, E.; Linczuk, P.; Wojeński, A.; Krawczyk, R.; Gąska, M.

    2018-01-01

    This paper presents the results of the energy resolution simulation for the triple GEM-based detector for x-ray quantum of 5.9 keV . Photons of this energy are emitted by 55Fe source, which is a standard calibration marker for this type of detectors. The calculations were made in Garfield++ in two stages. In the first stage, the distribution of the amount of primary electrons generated in the drift volume by the x-ray quantum was simulated using the Heed program. Secondly, the primary electrons of the resulting quantitative distribution were treated as a source of electron avalanches propagated through the whole volume of the triple GEM-based detector. The distribution of the obtained signals created a spectrum corresponding to the peak at 5.9 keV, which allowed us to determine the theoretical energy resolution of the detector. Its knowledge allows observing and improving the eventual experimental deterioration of the energy resolution, inevitably accompanying processes of registration and processing of the signals.

  2. Applications of a Fast Neutron Detector System to Verification of Special Nuclear Materials

    NASA Astrophysics Data System (ADS)

    Mayo, Douglas R.; Byrd, Roger C.; Ensslin, Norbert; Krick, Merlyn S.; Mercer, David J.; Miller, Michael C.; Prettyman, Thomas H.; Russo, Phyllis A.

    1998-04-01

    An array of boron-loaded plastic optically coupled to bismuth germanate scintillators has been developed to detect neutrons for measurement of special nuclear materials. The phoswiched detection system has the advantage of a high neutron detection efficiency and short die-away time. This is achieved by mixing the moderator (plastic) and the detector (^10B) at the molecular level. Simulations indicate that the neutron capture probabilities equal or exceed those of the current thermal neutron multiplicity techniques which have the moderator (polyethylene) and detectors (^3He gas proportional tubes) macroscopically separate. Experiments have been performed to characterize the response of these detectors and validate computer simulations. The fast neutron detection system may be applied to the quantitative assay of plutonium in high (α,n) backgrounds, with emphasis on safeguards and enviromental scenarios. Additional applications of the insturment, in a non-quantative mode, has been tested for possible verification activities involving dismantlement of nuclear weapons. A description of the detector system, simulations and preliminary data will be presented.

  3. Robust MOE Detector for DS-CDMA Systems with Signature Waveform Mismatch

    NASA Astrophysics Data System (ADS)

    Lin, Tsui-Tsai

    In this letter, a decision-directed MOE detector with excellent robustness against signature waveform mismatch is proposed for DS-CDMA systems. Both the theoretic analysis and computer simulation results demonstrate that the proposed detector can provide better SINR performance than that of conventional detectors.

  4. Position resolution simulations for the inverted-coaxial germanium detector, SIGMA

    NASA Astrophysics Data System (ADS)

    Wright, J. P.; Harkness-Brennan, L. J.; Boston, A. J.; Judson, D. S.; Labiche, M.; Nolan, P. J.; Page, R. D.; Pearce, F.; Radford, D. C.; Simpson, J.; Unsworth, C.

    2018-06-01

    The SIGMA Germanium detector has the potential to revolutionise γ-ray spectroscopy, providing superior energy and position resolving capabilities compared with current large volume state-of-the-art Germanium detectors. The theoretical position resolution of the detector as a function of γ-ray interaction position has been studied using simulated detector signals. A study of the effects of RMS noise at various energies has been presented with the position resolution ranging from 0.33 mm FWHM at Eγ = 1 MeV, to 0.41 mm at Eγ = 150 keV. An additional investigation into the effects pulse alignment have on pulse shape analysis and in turn, position resolution has been performed. The theoretical performance of SIGMA operating in an experimental setting is presented for use as a standalone detector and as part of an ancillary system.

  5. A silicon strip detector array for energy verification and quality assurance in heavy ion therapy.

    PubMed

    Debrot, Emily; Newall, Matthew; Guatelli, Susanna; Petasecca, Marco; Matsufuji, Naruhiro; Rosenfeld, Anatoly B

    2018-02-01

    The measurement of depth dose profiles for range and energy verification of heavy ion beams is an important aspect of quality assurance procedures for heavy ion therapy facilities. The steep dose gradients in the Bragg peak region of these profiles require the use of detectors with high spatial resolution. The aim of this work is to characterize a one dimensional monolithic silicon detector array called the "serial Dose Magnifying Glass" (sDMG) as an independent ion beam energy and range verification system used for quality assurance conducted for ion beams used in heavy ion therapy. The sDMG detector consists of two linear arrays of 128 silicon sensitive volumes each with an effective size of 2mm × 50μm × 100μm fabricated on a p-type substrate at a pitch of 200 μm along a single axis of detection. The detector was characterized for beam energy and range verification by measuring the response of the detector when irradiated with a 290 MeV/u 12 C ion broad beam incident along the single axis of the detector embedded in a PMMA phantom. The energy of the 12 C ion beam incident on the detector and the residual energy of an ion beam incident on the phantom was determined from the measured Bragg peak position in the sDMG. Ad hoc Monte Carlo simulations of the experimental setup were also performed to give further insight into the detector response. The relative response profiles along the single axis measured with the sDMG detector were found to have good agreement between experiment and simulation with the position of the Bragg peak determined to fall within 0.2 mm or 1.1% of the range in the detector for the two cases. The energy of the beam incident on the detector was found to vary less than 1% between experiment and simulation. The beam energy incident on the phantom was determined to be (280.9 ± 0.8) MeV/u from the experimental and (280.9 ± 0.2) MeV/u from the simulated profiles. These values coincide with the expected energy of 281 MeV/u. The sDMG detector response was studied experimentally and characterized using a Monte Carlo simulation. The sDMG detector was found to accurately determine the 12 C beam energy and is suited for fast energy and range verification quality assurance. It is proposed that the sDMG is also applicable for verification of treatment planning systems that rely on particle range. © 2017 American Association of Physicists in Medicine.

  6. Studies of the Low-energy Gamma Background

    NASA Astrophysics Data System (ADS)

    Bikit, K.; Mrđa, D.; Bikit, I.; Slivka, J.; Veskovic, M.; Knezevic, D.

    The investigations of contribution to the low-energy part of background gamma spectrum (below 100 keV) and knowing detection efficiency for this region are important for both, a fundamental, as well as for applied research. In this work, the components contributing to the low-energy region of background gamma spectrum for shielded detector are analyzed, including the production and spectral distribution of muon-induced continuous low-energy radiation in the vicinity of high-purity germanium detector.In addition, the detection efficiency for low energy gamma region is determined using the GEANT 4 simulation package. This technique offers excellent opportunity to predict the detection response in mentioned region. Unfortunately, the frequently weakly known dead layer thickness on the surface of the extended-range detector, as well as some processes which are not incorporated in simulation (e.g. charge collection from detector active volume) may limit the reliability of simulation technique. Thus, the 14, 17, 21, 26, 33, 59.5 keV transitions in the calibrated 241Am point source were used to check the simulated efficiencies.

  7. Cross-Section Measurements via the Activation Technique at the Cologne Clover Counting Setup

    NASA Astrophysics Data System (ADS)

    Heim, Felix; Mayer, Jan; Netterdon, Lars; Scholz, Philipp; Zilges, Andreas

    The activation technique is a widely used method for the determination of cross-section values for charged-particle induced reactions at astrophysically relevant energies. Since network calculations of nucleosynthesis processes often depend on reaction rates calculated in the scope of the Hauser-Feshbach statistical model, these cross-sections can be used to improve the nuclear-physics input-parameters like optical-model potentials (OMP), γ-ray strength functions, and nuclear level densities. In order to extend the available experimental database, the 108Cd(α, n)111Sn reaction cross section was investigated at ten energies between 10.2 and 13.5 MeV. As this reaction at these energies is almost only sensitive on the α-decay width, the results were compared to statistical model calculations using different models for the α-OMP. The irradiation as well as the consecutive γ-ray counting were performed at the Institute for Nuclear Physics of the University of Cologne using the 10 MV FN-Tandem accelerator and the Cologne Clover Counting Setup. This setup consists of two clover- type high purity germanium (HPGe) detectors in a close face-to-face geometry to cover a solid angle of almost 4π.

  8. New limits for the 2 νββ decay of 96Zr to excited nuclear states of 96Mo

    NASA Astrophysics Data System (ADS)

    Finch, Sean; Tornow, Werner

    2015-10-01

    The final results from our search for the 2 νββ decay of 96Zr to excited 0+ and 2+ states of 96Mo are presented. Such measurements provide valuable test cases for 2 νββ -decay nuclear matrix element calculations, which in turn are used to tune 0 νββ -decay nuclear matrix element calculations. After undergoing double- β decay to an excited state, the excited daughter nucleus decays to the ground state, emitting two coincident γ rays. These two γ rays are detected in coincidence by two HPGe detectors sandwiching the 96Zr sample, with a NaI veto in anti-coincidence. This experimental apparatus, located at the Kimballton Underground Research Facility (KURF), has previously measured the 2 νββ decay of 100Mo and 150Nd to excited nuclear states. Experimental limits on the T1 / 2 and corresponding nuclear matrix element are presented for each of these decays. As a byproduct of this experiment, limits were also set on the single- β decay of 96Zr. Supported by DOE Grant: DE-FG02-97ER41033.

  9. Radiological characterization and evaluation of high volume bauxite residue alkali activated concretes.

    PubMed

    Croymans, Tom; Schroeyers, Wouter; Krivenko, Pavel; Kovalchuk, Oleksandr; Pasko, Anton; Hult, Mikael; Marissens, Gerd; Lutter, Guillaume; Schreurs, Sonja

    2017-03-01

    Bauxite residue, also known as red mud, can be used as an aggregate in concrete products. The study involves the radiological characterization of different types of concretes containing bauxite residue from Ukraine. The activity concentrations of radionuclides from the 238 U, 232 Th decay series and 40 K were determined for concrete mixture samples incorporating 30, 40, 50, 60, 75, 85 and 90% (by mass) of bauxite residue using gamma-ray spectrometry with a HPGe detector. The studied bauxite residue can, from a radiological point of view using activity concentration indexes developed by Markkanen, be used in concrete for building materials and in road construction, even in percentages reaching 90% (by mass). However, when also occupational exposure is considered it is recommended to incorporate less than 75% (by mass) of Ukrainian bauxite residue during the construction of buildings in order to keep the dose to workers below the dose criterion used by Radiation Protection (RP) 122 (0.3 mSv/a). Considering RP122 for evaluation of the total effective dose to workers no restrictions are required for the use of the Ukrainian bauxite residue in road construction. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. Mercury mass measurement in fluorescent lamps via neutron activation analysis

    NASA Astrophysics Data System (ADS)

    Viererbl, L.; Vinš, M.; Lahodová, Z.; Fuksa, A.; Kučera, J.; Koleška, M.; Voljanskij, A.

    2015-11-01

    Mercury is an essential component of fluorescent lamps. Not all fluorescent lamps are recycled, resulting in contamination of the environment with toxic mercury, making measurement of the mercury mass used in fluorescent lamps important. Mercury mass measurement of lamps via instrumental neutron activation analysis (NAA) was tested under various conditions in the LVR-15 research reactor. Fluorescent lamps were irradiated in different positions in vertical irradiation channels and a horizontal channel in neutron fields with total fluence rates from 3×108 cm-2 s-1 to 1014 cm-2 s-1. The 202Hg(n,γ)203Hg nuclear reaction was used for mercury mass evaluation. Activities of 203Hg and others induced radionuclides were measured via gamma spectrometry with an HPGe detector at various times after irradiation. Standards containing an Hg2Cl2 compound were used to determine mercury mass. Problems arise from the presence of elements with a large effective cross section in luminescent material (europium, antimony and gadolinium) and glass (boron). The paper describes optimization of the NAA procedure in the LVR-15 research reactor with particular attention to influence of neutron self-absorption in fluorescent lamps.

  11. Lichens as environmental risk detectors

    NASA Astrophysics Data System (ADS)

    Caridi, F.; D'Agostino, M.; Messina, M.; Marcianò, G.; Grioli, L.; Belvedere, A.; Marguccio, S.; Belmusto, G.

    2017-04-01

    Several studies carried out after the Chernobyl nuclear accident in 1986 showed that lichens are suitable biomonitors of the fall-out, given their long life expectancy. 137Cs activity concentrations were measured through HPGe gamma spectrometry in different epiphytic lichens ( Usnea SPP, Platismatia glauca, Pseudevernia furfuracea, Ramalina SPP), collected from three sampling sites in the Calabria region, south of Italy. Data on variations in the contents of airborne particulates heavy metals, As, Be, Cd, Cu, Hg, Pb and Zn, measured in the thalli of the investigated lichens through inductively coupled plasma mass spectrometry (ICP-MS), were reported in accordance with a lichen thalli naturalness/alteration scale. Energy-dispersive X-ray microanalysis in a scanning electron microscope (SEM-EDX), with an electron beam of 20keV, that interacts with the sample leading to the emission of characteristic X-rays as secondary radiation, was also employed to investigate about the chemistry of the adherent particles to the surface of investigated lichens and about the possible interaction between them and the surrounding environment. Data obtained in this article provide useful information on the environmental risk of the studied area and can be further used for a radiological and chemical mapping.

  12. NDA Batch 2002-13

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hollister, R

    QC sample results (daily background check drum and 100-gram SGS check drum) were within acceptance criteria established by WIPP's Quality Assurance Objectives for TRU Waste Characterization. Replicate runs were performed on drum LL85501243TRU. Replicate measurement results are identical at the 95% confidence level as established by WIPP criteria. HWM NCAR No. 02-1000168 issued on 17-Oct-2002 regarding a partially dislodged Cd sheet filter on the HPGe coaxial detector. This physical geometry occurred on 01-Oct-2002 and was not corrected until 10-Oct-2002, during which period is inclusive of the present batch run of drums. Per discussions among the Independent Technical Reviewer, Expert Reviewermore » and the Technical QA Supervisor, as well as in consultation with John Fleissner, Technical Point of Contact from Canberra, the analytical results are technically reliable. All QC standard runs during this period were in control. Data packet for SGS Batch 2002-13 generated using passive gamma-ray spectroscopy with the Pu Facility SGS unit is technically reasonable. All QC samples are in compliance with establiShed control limits. The batch data packet has been reviewed for correctness, completeness, consistency and compliance with WIPP's Quality Assurance Objectives and determined to be acceptable.« less

  13. Shielding experiments by the JASMIN Collaboration at Fermilab (II) - radioactivity measurement induced by secondary particles from the anti-proton production target

    DOE PAGES

    Hiroshi, Yashima; Norihiro, Matsuda; Yoshimi, Kasugai; ...

    2011-08-01

    The JASMIN Collaboration has performed an experiment to conduct measurements of nuclear reaction rates around the anti-proton production (Pbar) target at the Fermi National Accelerator Laboratory (FNAL). At the Pbar target station, the target, consisting of an Inconel 600 cylinder, was irradiated by a 120 GeV/c proton beam from the FNAL Main Injector. The beam intensity was 3.6 x 10 12 protons per second. The samples of Al, Nb, Cu, and Au were placed near the target to investigate the spatial and energy distribution of secondary particles emitted from it. After irradiation, the induced activities of the samples were measuredmore » by studying their gamma ray spectra using HPGe detectors. The production rates of 30 nuclides induced in Al, Nb, Cu, Au samples were obtained. These rates increase for samples placed in a forward (small angle) position relative to the target. The angular dependence of these reaction rates becomes larger for increasing threshold energy. These experimental results are compared with Monte Carlo calculations. The calculated results generally agree with the experimental results to within a factor of 2 to 3.« less

  14. VERTICAL MIGRATION OF RADIONUCLIDES IN THE VICINITY OF THE CHERNOBYL CONFINEMENT SHELTER

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Farfan, E.; Jannik, T.; Marra, J.

    2011-10-01

    Studies on vertical migration of Chernobyl-origin radionuclides in the 5-km zone of the Chernobyl Nuclear Power Plant (ChNPP) in the area of the Red Forest experimental site were completed. Measurements were made by gamma spectrometric methods using high purity germanium (HPGe) detectors with beryllium windows. Alpha-emitting isotopes of plutonium were determined by the measurement of the x-rays from their uranium progeny. The presence of {sup 60}Co, {sup 134,137}Cs, {sup 154,155}Eu, and {sup 241}Am in all soil layers down to a depth of 30 cm was observed. The presence of {sup 137}Cs and {sup 241}Am were noted in the area containingmore » automorphous soils to a depth of 60 cm. In addition, the upper soil layers at the test site were found to contain {sup 243}Am and {sup 243}Cm. Over the past ten years, the {sup 241}Am/{sup 137}Cs ratio in soil at the experimental site has increased by a factor of 3.4, nearly twice as much as would be predicted based solely on radioactive decay. This may be due to 'fresh' fallout emanating from the ChNPP Confinement Shelter.« less

  15. Measurements of fission product yield in the neutron-induced fission of 238U with average energies of 9.35 MeV and 12.52 MeV

    NASA Astrophysics Data System (ADS)

    Mukerji, Sadhana; Krishnani, Pritam Das; Shivashankar, Byrapura Siddaramaiah; Mulik, Vikas Kaluram; Suryanarayana, Saraswatula Venkat; Naik, Haladhara; Goswami, Ashok

    2014-07-01

    The yields of various fission products in the neutron-induced fission of 238U with the flux-weightedaveraged neutron energies of 9.35 MeV and 12.52 MeV were determined by using an off-line gammaray spectroscopic technique. The neutrons were generated using the 7Li(p, n) reaction at Bhabha Atomic Research Centre-Tata Institute of Fundamental Research Pelletron facility, Mumbai. The gamma- ray activities of the fission products were counted in a highly-shielded HPGe detector over a period of several weeks to identify the decaying fission products. At both the neutron energies, the fission-yield values are reported for twelve fission product. The results obtained from the present work have been compared with the similar data for mono-energetic neutrons of comparable energy from the literature and are found to be in good agreement. The peak-to-valley (P/V) ratios were calculated from the fission-yield data and were found to decreases for neutron energy from 9.35 to 12.52 MeV, which indicates the role of excitation energy. The effect of the nuclear structure on the fission product-yield is discussed.

  16. Shielding experiments by the JASMIN collaboration at Fermilab (II) - Radioactivity measurement induced by secondary particles from the anti-proton production target

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yashima, Hiroshi; /Kyoto U., KURRI; Matsuda, Norihiro

    2011-01-01

    The JASMIN Collaboration has performed an experiment to conduct measurements of nuclear reaction rates around the anti-proton production (Pbar) target at the Fermi National Accelerator Laboratory (FNAL). At the Pbar target station, the target, consisting an Inconel 600 cylinder, was irradiated by a 120 GeV/c proton beam from the FNAL Main Injector. The beam intensity was 3.6 x 10{sub 12} protons per second. Samples of Al, Nb, Cu, and Au were placed near the target to investigate the spatial and energy distribution of secondary particles emitted from it. After irradiation, the induced activities of the samples were measured by studyingmore » their gamma ray spectra using HPGe detectors. The production rates of 30 nuclides induced in Al, Nb, Cu, Au samples were obtained. These rates increase for samples placed in a forward (small angle) position relative to the target. The angular dependence of these reaction rates becomes larger for increasing threshold energy. These experimental results are compared with Monte Carlo calculations. The calculated results generally agree with the experimental results to within a factor of 2 to 3.« less

  17. On-line detection of key radionuclides for fuel-rod failure in a pressurized water reactor.

    PubMed

    Qin, Guoxiu; Chen, Xilin; Guo, Xiaoqing; Ni, Ning

    2016-08-01

    For early on-line detection of fuel rod failure, the key radionuclides useful in monitoring must leak easily from failing rods. Yield, half-life, and mass share of fission products that enter the primary coolant also need to be considered in on-line analyses. From all the nuclides that enter the primary coolant during fuel-rod failure, (135)Xe and (88)Kr were ultimately chosen as crucial for on-line monitoring of fuel-rod failure. A monitoring system for fuel-rod failure detection for pressurized water reactor (PWR) based on the LaBr3(Ce) detector was assembled and tested. The samples of coolant from the PWR were measured using the system as well as a HPGe γ-ray spectrometer. A comparison showed the method was feasible. Finally, the γ-ray spectra of primary coolant were measured under normal operations and during fuel-rod failure. The two peaks of (135)Xe (249.8keV) and (88)Kr (2392.1keV) were visible, confirming that the method is capable of monitoring fuel-rod failure on-line. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Measurement of 235U(n,n'γ) and 235U(n,2nγ) reaction cross sections

    NASA Astrophysics Data System (ADS)

    Kerveno, M.; Thiry, J. C.; Bacquias, A.; Borcea, C.; Dessagne, P.; Drohé, J. C.; Goriely, S.; Hilaire, S.; Jericha, E.; Karam, H.; Negret, A.; Pavlik, A.; Plompen, A. J. M.; Romain, P.; Rouki, C.; Rudolf, G.; Stanoiu, M.

    2013-02-01

    The design of generation IV nuclear reactors and the studies of new fuel cycles require knowledge of the cross sections of various nuclear reactions. Our research is focused on (n,xnγ) reactions occurring in these new reactors. The aim is to measure unknown cross sections and to reduce the uncertainty on present data for reactions and isotopes of interest for transmutation or advanced reactors. The present work studies the 235U(n,n'γ) and 235U(n,2nγ) reactions in the fast neutron energy domain (up to 20 MeV). The experiments were performed with the Geel electron linear accelerator GELINA, which delivers a pulsed white neutron beam. The time characteristics enable measuring neutron energies with the time-of-flight (TOF) technique. The neutron induced reactions [in this case inelastic scattering and (n,2n) reactions] are identified by on-line prompt γ spectroscopy with an experimental setup including four high-purity germanium (HPGe) detectors. A fission ionization chamber is used to monitor the incident neutron flux. The experimental setup and analysis methods are presented and the model calculations performed with the TALYS-1.2 code are discussed.

  19. Determination of elements in hospital waste with neutron activation analysis method

    NASA Astrophysics Data System (ADS)

    Dwijananti, P.; Astuti, B.; Alwiyah; Fianti

    2018-03-01

    The producer of the biggest B3 waste is hospital. The waste is from medical and laboratory activities. The purpose of this study is to determine the elements contained in the liquid waste from hospital and calculate the levels of these elements. This research was done by analysis of the neutron activation conducted at BATAN Yogyakarta. The neutron activation analysis is divided into two stages: activation of the samples using neutron sources of reactor Kartini, then chopping by using a set of tools, gamma spectrometer with HPGe detector. Qualitative and quantitative analysis were done by matching the gamma spectrum peak to the Neutron Activation Table. The sample was taken from four points of the liquid waste treatment plant (WWTP) Bhakti Wira Tamtama Semarang hospital. The results showed that the samples containing elements of Cr, Zn, Fe, Co, and Na, with the levels of each element is Cr (0.033 - 0.075) mg/L, Zn (0.090 - 1.048) mg/L, Fe (2.937-37.743) mg/L, Co (0.005-0.023) mg/L, and Na (61.088-116.330) mg/L. Comparing to the standard value, the liquid is safe to the environment.

  20. A Radiation Laboratory Curriculum Development at Western Kentucky University

    NASA Astrophysics Data System (ADS)

    Barzilov, Alexander P.; Novikov, Ivan S.; Womble, Phil C.

    2009-03-01

    We present the latest developments for the radiation laboratory curriculum at the Department of Physics and Astronomy of Western Kentucky University. During the last decade, the Applied Physics Institute (API) at WKU accumulated various equipment for radiation experimentation. This includes various neutron sources (computer controlled d-t and d-d neutron generators, and isotopic 252 Cf and PuBe sources), the set of gamma sources with various intensities, gamma detectors with various energy resolutions (NaI, BGO, GSO, LaBr and HPGe) and the 2.5-MeV Van de Graaff particle accelerator. XRF and XRD apparatuses are also available for students and members at the API. This equipment is currently used in numerous scientific and teaching activities. Members of the API also developed a set of laboratory activities for undergraduate students taking classes from the physics curriculum (Nuclear Physics, Atomic Physics, and Radiation Biophysics). Our goal is to develop a set of radiation laboratories, which will strengthen the curriculum of physics, chemistry, geology, biology, and environmental science at WKU. The teaching and research activities are integrated into real-world projects and hands-on activities to engage students. The proposed experiments and their relevance to the modern status of physical science are discussed.

  1. Analysis of radiocaesium in the Lebanese soil one decade after the Chernobyl accident.

    PubMed

    El Samad, O; Zahraman, K; Baydoun, R; Nasreddine, M

    2007-01-01

    Fallout from the Chernobyl reactor accident due to the transport of a radioactive cloud over Lebanon in the beginning of May 1986 was studied 12 years after the accident for determining the level of (137)Cs concentration in soil. Gamma spectroscopy measurements were performed by using coaxial high sensitivity HPGe detectors. More than 90 soil samples were collected from points uniformly distributed throughout the land of Lebanon in order to evaluate their radioactivity. The data obtained showed a relatively high (137)Cs activity per surface area contamination, up to 6545Bqm(-2) in the top soil layer 0-3cm. The average activity of (137)Cs in the top soil layer 0-3cm in depth was 59.7Bqkg(-1) dry soil ranging from 15 to 119Bqkg(-1) dry soil. The horizontal variability was found to be about 45% between the sampling sites. The depth distribution of total (137)Cs activity in soil showed an exponential decrease. Estimation of the annual effective dose due to external radiation from (137)Cs contaminated soil for selected sites gave values ranging from 19.3 to 91.6 micro Svy(-1).

  2. Radiological Risk Assessments for Occupational Exposure at Fuel Fabrication Facility in AlTuwaitha Site Baghdad – Iraq by using RESRAD Computer Code

    NASA Astrophysics Data System (ADS)

    Ibrahim, Ziadoon H.; Ibrahim, S. A.; Mohammed, M. K.; Shaban, A. H.

    2018-05-01

    The purpose of this study is to evaluate the radiological risks for workers for one year of their activities at Fuel Fabrication Facility (FFF) so as to make the necessary protection to prevent or minimize risks resulted from these activities this site now is under the Iraqi decommissioning program (40). Soil samples surface and subsurface were collected from different positions of this facility and analyzed by gamma rays spectroscopy technique High Purity Germanium detector (HPGe) was used. It was found out admixture of radioactive isotopes (232Th 40K 238U 235U137Cs) according to the laboratory results the highest values were (975758) for 238U (21203) for 235U (218) for 232Th (4046) for 40K and (129) for 137Cs in (Bqkg1) unit. The annual total radiation dose and risks were estimated by using RESRAD (onsite) 70 computer code. The highest total radiation dose was (5617μSv/year) in area that represented by soil sample (S7) and the radiological risks morbidity and mortality (118E02 8661E03) respectively in the same area

  3. Monte Carlo code G3sim for simulation of plastic scintillator detectors with wavelength shifter fiber readout.

    PubMed

    Mohanty, P K; Dugad, S R; Gupta, S K

    2012-04-01

    A detailed description of a compact Monte Carlo simulation code "G3sim" for studying the performance of a plastic scintillator detector with wavelength shifter (WLS) fiber readout is presented. G3sim was developed for optimizing the design of new scintillator detectors used in the GRAPES-3 extensive air shower experiment. Propagation of the blue photons produced by the passage of relativistic charged particles in the scintillator is treated by incorporating the absorption, total internal, and diffuse reflections. Capture of blue photons by the WLS fibers and subsequent re-emission of longer wavelength green photons is appropriately treated. The trapping and propagation of green photons inside the WLS fiber is treated using the laws of optics for meridional and skew rays. Propagation time of each photon is taken into account for the generation of the electrical signal at the photomultiplier. A comparison of the results from G3sim with the performance of a prototype scintillator detector showed an excellent agreement between the simulated and measured properties. The simulation results can be parametrized in terms of exponential functions providing a deeper insight into the functioning of these versatile detectors. G3sim can be used to aid the design and optimize the performance of scintillator detectors prior to actual fabrication that may result in a considerable saving of time, labor, and money spent. © 2012 American Institute of Physics

  4. Electrical properties study under radiation of the 3D-open-shell-electrode detector

    NASA Astrophysics Data System (ADS)

    Liu, Manwen; Li, Zheng

    2018-05-01

    Since the 3D-Open-Shell-Electrode Detector (3DOSED) is proposed and the structure is optimized, it is important to study 3DOSED's electrical properties to determine the detector's working performance, especially in the heavy radiation environments, like the Large Hadron Collider (LHC) and it's upgrade, the High Luminosity (HL-LHC) at CERN. In this work, full 3D technology computer-aided design (TCAD) simulations have been done on this novel silicon detector structure. Simulated detector properties include the electric field distribution, the electric potential distribution, current-voltage (I-V) characteristics, capacitance-voltage (C-V) characteristics, charge collection property, and full depletion voltage. Through the analysis of calculations and simulation results, we find that the 3DOSED's electric field and potential distributions are very uniform, even in the tiny region near the shell openings with little perturbations. The novel detector fits the designing purpose of collecting charges generated by particle/light in a good fashion with a well defined funnel shape of electric potential distribution that makes these charges drifting towards the center collection electrode. Furthermore, by analyzing the I-V, C-V, charge collection property and full depletion voltage, we can expect that the novel detector will perform well, even in the heavy radiation environments.

  5. Track reconstruction and particle identification developments for a study of event-by-event fluctuations in heavy ion collisions at NICA

    NASA Astrophysics Data System (ADS)

    Mudrokh, A. A.; Zinchenko, A. I.

    2017-01-01

    A Monte Carlo simulation of heavy ion collisions (Au+Au) has been performed at MPD (Multi Purpose Detector) at NICA (Dubna) for a study of the possible critical point in the phase diagram of the hot nuclear matter. The simulation took into account real detector effects with as many details as possible to properly describe the apparatus response. Particle identification (PID) has been tuned to account for modifications in track reconstruction. Some results on hadron identification in the TPC and TOF (Time Of Flight) detectors with realistically simulated response have been also obtained.

  6. Modeling and analysis of hybrid pixel detector deficiencies for scientific applications

    NASA Astrophysics Data System (ADS)

    Fahim, Farah; Deptuch, Grzegorz W.; Hoff, James R.; Mohseni, Hooman

    2015-08-01

    Semiconductor hybrid pixel detectors often consist of a pixellated sensor layer bump bonded to a matching pixelated readout integrated circuit (ROIC). The sensor can range from high resistivity Si to III-V materials, whereas a Si CMOS process is typically used to manufacture the ROIC. Independent, device physics and electronic design automation (EDA) tools are used to determine sensor characteristics and verify functional performance of ROICs respectively with significantly different solvers. Some physics solvers provide the capability of transferring data to the EDA tool. However, single pixel transient simulations are either not feasible due to convergence difficulties or are prohibitively long. A simplified sensor model, which includes a current pulse in parallel with detector equivalent capacitor, is often used; even then, spice type top-level (entire array) simulations range from days to weeks. In order to analyze detector deficiencies for a particular scientific application, accurately defined transient behavioral models of all the functional blocks are required. Furthermore, various simulations, such as transient, noise, Monte Carlo, inter-pixel effects, etc. of the entire array need to be performed within a reasonable time frame without trading off accuracy. The sensor and the analog front-end can be modeling using a real number modeling language, as complex mathematical functions or detailed data can be saved to text files, for further top-level digital simulations. Parasitically aware digital timing is extracted in a standard delay format (sdf) from the pixel digital back-end layout as well as the periphery of the ROIC. For any given input, detector level worst-case and best-case simulations are performed using a Verilog simulation environment to determine the output. Each top-level transient simulation takes no more than 10-15 minutes. The impact of changing key parameters such as sensor Poissonian shot noise, analog front-end bandwidth, jitter due to clock distribution etc. can be accurately analyzed to determine ROIC architectural viability and bottlenecks. Hence the impact of the detector parameters on the scientific application can be studied.

  7. Time-resolved diode dosimetry calibration through Monte Carlo modeling for in vivo passive scattered proton therapy range verification.

    PubMed

    Toltz, Allison; Hoesl, Michaela; Schuemann, Jan; Seuntjens, Jan; Lu, Hsiao-Ming; Paganetti, Harald

    2017-11-01

    Our group previously introduced an in vivo proton range verification methodology in which a silicon diode array system is used to correlate the dose rate profile per range modulation wheel cycle of the detector signal to the water-equivalent path length (WEPL) for passively scattered proton beam delivery. The implementation of this system requires a set of calibration data to establish a beam-specific response to WEPL fit for the selected 'scout' beam (a 1 cm overshoot of the predicted detector depth with a dose of 4 cGy) in water-equivalent plastic. This necessitates a separate set of measurements for every 'scout' beam that may be appropriate to the clinical case. The current study demonstrates the use of Monte Carlo simulations for calibration of the time-resolved diode dosimetry technique. Measurements for three 'scout' beams were compared against simulated detector response with Monte Carlo methods using the Tool for Particle Simulation (TOPAS). The 'scout' beams were then applied in the simulation environment to simulated water-equivalent plastic, a CT of water-equivalent plastic, and a patient CT data set to assess uncertainty. Simulated detector response in water-equivalent plastic was validated against measurements for 'scout' spread out Bragg peaks of range 10 cm, 15 cm, and 21 cm (168 MeV, 177 MeV, and 210 MeV) to within 3.4 mm for all beams, and to within 1 mm in the region where the detector is expected to lie. Feasibility has been shown for performing the calibration of the detector response for three 'scout' beams through simulation for the time-resolved diode dosimetry technique in passive scattered proton delivery. © 2017 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  8. A New Simulation Framework for the Electron-Ion Collider

    NASA Astrophysics Data System (ADS)

    Arrington, John

    2017-09-01

    Last year, a collaboration between Physics Division and High-Energy Physics at Argonne was formed to enable significantly broader contributions to the development of the Electron-Ion Collider. This includes efforts in accelerator R&D, theory, simulations, and detector R&D. I will give a brief overview of the status of these efforts, with emphasis on the aspects aimed at enabling the community to more easily become involved in evaluation of physics, detectors, and details of spectrometer designs. We have put together a new, easy-to-use simulation framework using flexible software tools. The goal is to enable detailed simulations to evaluate detector performance and compare detector designs. In addition, a common framework capable of providing detailed simulations of different spectrometer designs will allow for fully consistent evaluations of the physics reach of different spectrometer designs or detector systems for a variety of physics channels. In addition, new theory efforts will provide self-consistent models of GPDs (including QCD evolution) and TMDs in nucleons and light nuclei, as well as providing more detailed physics input for the evaluation of some new observables. This material is based upon work supported by Laboratory Directed Research and Development (LDRD) funding from Argonne National Laboratory, provided by the Director, Office of Science, of the U.S. Department of Energy under Contract DE-AC02-06CH11357.

  9. The detector response matrices of the burst and transient source experiment (BATSE) on the Compton Gamma Ray Observatory

    NASA Technical Reports Server (NTRS)

    Pendleton, Geoffrey N.; Paciesas, William S.; Mallozzi, Robert S.; Koshut, Tom M.; Fishman, Gerald J.; Meegan, Charles A.; Wilson, Robert B.; Horack, John M.; Lestrade, John Patrick

    1995-01-01

    The detector response matrices for the Burst And Transient Source Experiment (BATSE) on board the Compton Gamma Ray Observatory (CGRO) are described, including their creation and operation in data analysis. These response matrices are a detailed abstract representation of the gamma-ray detectors' operating characteristics that are needed for data analysis. They are constructed from an extensive set of calibration data coupled with a complex geometry electromagnetic cascade Monte Carlo simulation code. The calibration tests and simulation algorithm optimization are described. The characteristics of the BATSE detectors in the spacecraft environment are also described.

  10. Status of the EDDA experiment at COSY

    NASA Astrophysics Data System (ADS)

    Scobel, W.; EDDA Collaboration; Bisplinghoff, J.; Bollmann, R.; Cloth, P.; Dohrmann, F.; Dorner, G.; Drüke, V.; Ernst, J.; Eversheim, P. D.; Filges, D.; Gasthuber, M.; Gebel, R.; Groß, A.; Groß-Hardt, R.; Hinterberger, F.; Jahn, R.; Lahr, U.; Langkau, R.; Lippert, G.; Mayer-Kuckuk, T.; Maschuw, R.; Mertler, G.; Metsch, B.; Mosel, F.; Paetz gen Schieck, H.; Petry, H. R.; Prasuhn, D.; von Przewoski, B.; Rohdjeß, H.; Rosendaal, D.; von Rossen, P.; Scheid, H.; Schirm, N.; Schwandt, F.; Stein, H.; Theis, D.; Weber, J.; Wiedmann, W.; Woller, K.; Ziegler, R.

    1993-07-01

    The EDDA experiment is designed to study p + p excitation functions with high energy resolution and narrow step size in the kinetic energy range from 250 MeV to 2500 MeV at the Cooler Synchrotron COSY. Measurements during the accelertion phase in conjunction with internal targets will allow to achieve a fast and precise energy variation. Prototypes of the detector elements and the fiber target have been extensively tested with proton and electron beams; the detector performance and trigger efficiency have been studied in Monte Carlo simulations. In this contribution, results concerning detector design, prototype studies, Monte Carlo simulations and the anticipated detector resolutions will be reported.

  11. Low Gain Avalanche Detectors (LGAD) for particle physics and synchrotron applications

    NASA Astrophysics Data System (ADS)

    Moffat, N.; Bates, R.; Bullough, M.; Flores, L.; Maneuski, D.; Simon, L.; Tartoni, N.; Doherty, F.; Ashby, J.

    2018-03-01

    A new avalanche silicon detector concept is introduced with a low gain in the region of ten, known as a Low Gain Avalanche Detector, LGAD. The detector's characteristics are simulated via a full process simulation to obtain the required doping profiles which demonstrate the desired operational characteristics of high breakdown voltage (500 V) and a gain of 10 at 200 V reverse bias for X-ray detection. The first low gain avalanche detectors fabricated by Micron Semiconductor Ltd are presented. The doping profiles of the multiplication junctions were measured with SIMS and reproduced by simulating the full fabrication process which enabled further development of the manufacturing process. The detectors are 300 μm thick p-type silicon with a resistivity of 8.5 kΩcm, which fully depletes at 116 V. The current characteristics are presented and demonstrate breakdown voltages in excess of 500 V and a current density of 40 to 100 nAcm‑2 before breakdown measured at 20oC. The gain of the LGAD has been measured with a red laser (660 nm) and shown to be between 9 and 12 for an external bias voltage range from 150 V to 300 V.

  12. A Detailed FLUKA-2005 Monte Carlo Simulation for the ATIC Detector

    NASA Technical Reports Server (NTRS)

    Gunasingha, R. M.; Fazely, A. R.; Adams, J. H.; Ahn, H. S.; Bashindzhagyan, G. L.; Batkov, K. E.; Chang, J.; Christl, M.; Ganel, O.; Guzik, T. G.

    2006-01-01

    We have performed a detailed Monte Carlo (MC) calculation for the Advanced thin Ionization Calorimeter (ATIC) detector using the MC code FLUKA-2005 which is capable of simulating particles up to 10 PeV. The ATIC detector has completed two successful balloon flights from McMurdo, Antarctica lasting a total of more than 35 days. ATIC is designed as a multiple, long duration balloon Bight, investigation of the cosmic ray spectra from below 50 GeV to near 100 TeV total energy; using a fully active Bismuth Germanate @GO) calorimeter. It is equipped with a large mosaic of silicon detector pixels capable of charge identification and as a particle tracking system, three projective layers of x-y scintillator hodoscopes were employed, above, in the middle and below a 0.75 nuclear interaction length graphite target. Our calculations are part of an analysis package of both A- and energy-dependences of different nuclei interacting with the ATIC detector. The MC simulates the responses of different components of the detector such as the Simatrix, the scintillator hodoscopes and the BGO calorimeter to various nuclei. We also show comparisons of the FLUKA-2005 MC calculations with a GEANT calculation and data for protons, He and CNO.

  13. Absolute efficiency calibration of 6LiF-based solid state thermal neutron detectors

    NASA Astrophysics Data System (ADS)

    Finocchiaro, Paolo; Cosentino, Luigi; Lo Meo, Sergio; Nolte, Ralf; Radeck, Desiree

    2018-03-01

    The demand for new thermal neutron detectors as an alternative to 3He tubes in research, industrial, safety and homeland security applications, is growing. These needs have triggered research and development activities about new generations of thermal neutron detectors, characterized by reasonable efficiency and gamma rejection comparable to 3He tubes. In this paper we show the state of the art of a promising low-cost technique, based on commercial solid state silicon detectors coupled with thin neutron converter layers of 6LiF deposited onto carbon fiber substrates. A few configurations were studied with the GEANT4 simulation code, and the intrinsic efficiency of the corresponding detectors was calibrated at the PTB Thermal Neutron Calibration Facility. The results show that the measured intrinsic detection efficiency is well reproduced by the simulations, therefore validating the simulation tool in view of new designs. These neutron detectors have also been tested at neutron beam facilities like ISIS (Rutherford Appleton Laboratory, UK) and n_TOF (CERN) where a few samples are already in operation for beam flux and 2D profile measurements. Forthcoming applications are foreseen for the online monitoring of spent nuclear fuel casks in interim storage sites.

  14. A new kind of metal detector based on chaotic oscillator

    NASA Astrophysics Data System (ADS)

    Hu, Wenjing

    2017-12-01

    The sensitivity of a metal detector greatly depends on the identification ability to weak signals from the probe. In order to improve the sensitivity of metal detectors, this paper applies the Duffing chaotic oscillator to metal detectors based on its characteristic which is very sensitive to weak periodic signals. To make a suitable Duffing system for detectors, this paper computes two Lyapunov characteristics exponents of the Duffing oscillator, which help to obtain the threshold of the Duffing system in the critical state accurately and give quantitative criteria for chaos. Meanwhile, a corresponding simulation model of the chaotic oscillator is made by the Simulink tool box of Matlab. Simulation results shows that Duffing oscillator is very sensitive to sinusoidal signals in high frequency cases. And experimental results show that the measurable diameter of metal particles is about 1.5mm. It indicates that this new method can feasibly and effectively improve the metal detector sensitivity.

  15. Evaluation of PET Imaging Resolution Using 350 mu{m} Pixelated CZT as a VP-PET Insert Detector

    NASA Astrophysics Data System (ADS)

    Yin, Yongzhi; Chen, Ximeng; Li, Chongzheng; Wu, Heyu; Komarov, Sergey; Guo, Qingzhen; Krawczynski, Henric; Meng, Ling-Jian; Tai, Yuan-Chuan

    2014-02-01

    A cadmium-zinc-telluride (CZT) detector with 350 μm pitch pixels was studied in high-resolution positron emission tomography (PET) imaging applications. The PET imaging system was based on coincidence detection between a CZT detector and a lutetium oxyorthosilicate (LSO)-based Inveon PET detector in virtual-pinhole PET geometry. The LSO detector is a 20 ×20 array, with 1.6 mm pitches, and 10 mm thickness. The CZT detector uses ac 20 ×20 ×5 mm substrate, with 350 μm pitch pixelated anodes and a coplanar cathode. A NEMA NU4 Na-22 point source of 250 μm in diameter was imaged by this system. Experiments show that the image resolution of single-pixel photopeak events was 590 μm FWHM while the image resolution of double-pixel photopeak events was 640 μm FWHM. The inclusion of double-pixel full-energy events increased the sensitivity of the imaging system. To validate the imaging experiment, we conducted a Monte Carlo (MC) simulation for the same PET system in Geant4 Application for Emission Tomography. We defined LSO detectors as a scanner ring and 350 μm pixelated CZT detectors as an insert ring. GATE simulated coincidence data were sorted into an insert-scanner sinogram and reconstructed. The image resolution of MC-simulated data (which did not factor in positron range and acolinearity effect) was 460 μm at FWHM for single-pixel events. The image resolutions of experimental data, MC simulated data, and theoretical calculation are all close to 500 μm FWHM when the proposed 350 μm pixelated CZT detector is used as a PET insert. The interpolation algorithm for the charge sharing events was also investigated. The PET image that was reconstructed using the interpolation algorithm shows improved image resolution compared with the image resolution without interpolation algorithm.

  16. Simulation study of signal formation in position sensitive planar p-on-n silicon detectors after short range charge injection

    NASA Astrophysics Data System (ADS)

    Peltola, T.; Eremin, V.; Verbitskaya, E.; Härkönen, J.

    2017-09-01

    Segmented silicon detectors (micropixel and microstrip) are the main type of detectors used in the inner trackers of Large Hadron Collider (LHC) experiments at CERN. Due to the high luminosity and eventual high fluence of energetic particles, detectors with fast response to fit the short shaping time of 20-25 ns and sufficient radiation hardness are required. Charge collection measurements carried out at the Ioffe Institute have shown a reversal of the pulse polarity in the detector response to short-range charge injection. Since the measured negative signal is about 30-60% of the peak positive signal, the effect strongly reduces the CCE even in non-irradiated detectors. For further investigation of the phenomenon the measurements have been reproduced by TCAD simulations. As for the measurements, the simulation study was applied for the p-on-n strip detectors similar in geometry to those developed for the ATLAS experiment and for the Ioffe Institute designed p-on-n strip detectors with each strip having a window in the metallization covering the p+ implant, allowing the generation of electron-hole pairs under the strip implant. Red laser scans across the strips and the interstrip gap with varying laser diameters and Si-SiO2 interface charge densities (Qf) were carried out. The results verify the experimentally observed negative response along the scan in the interstrip gap. When the laser spot is positioned on the strip p+ implant the negative response vanishes and the collected charge at the active strip increases respectively. The simulation results offer a further insight and understanding of the influence of the oxide charge density in the signal formation. The main result of the study is that a threshold value of Qf, that enables negligible losses of collected charges, is defined. The observed effects and details of the detector response for different charge injection positions are discussed in the context of Ramo's theorem.

  17. Proton Straggling in Thick Silicon Detectors

    NASA Technical Reports Server (NTRS)

    Selesnick, R. S.; Baker, D. N.; Kanekal, S. G.

    2017-01-01

    Straggling functions for protons in thick silicon radiation detectors are computed by Monte Carlo simulation. Mean energy loss is constrained by the silicon stopping power, providing higher straggling at low energy and probabilities for stopping within the detector volume. By matching the first four moments of simulated energy-loss distributions, straggling functions are approximated by a log-normal distribution that is accurate for Vavilov k is greater than or equal to 0:3. They are verified by comparison to experimental proton data from a charged particle telescope.

  18. Output factor determination based on Monte Carlo simulation for small cone field in 10-MV photon beam.

    PubMed

    Fukata, Kyohei; Sugimoto, Satoru; Kurokawa, Chie; Saito, Akito; Inoue, Tatsuya; Sasai, Keisuke

    2018-06-01

    The difficulty of measuring output factor (OPF) in a small field has been frequently discussed in recent publications. This study is aimed to determine the OPF in a small field using 10-MV photon beam and stereotactic conical collimator (cone). The OPF was measured by two diode detectors (SFD, EDGE detector) and one micro-ion chamber (PinPoint 3D chamber) in a water phantom. A Monte Carlo simulation using simplified detector model was performed to obtain the correction factor for the detector measurements. About 12% OPF difference was observed in the measurement at the smallest field (7.5 mm diameter) for EDGE detector and PinPoint 3D chamber. By applying the Monte Carlo-based correction factor to the measurement, the maximum discrepancy among the three detectors was reduced to within 3%. The results indicate that determination of OPF in a small field should be carefully performed. Especially, detector choice and appropriate correction factor application are very important in this regard.

  19. Implementation of the P barANDA Planar-GEM tracking detector in Monte Carlo simulations

    NASA Astrophysics Data System (ADS)

    Divani Veis, Nazila; Ehret, Andre; Firoozabadi, Mohammad M.; Karabowicz, Radoslaw; Maas, Frank; Saito, Nami; Saito, Takehiko R.; Voss, Bernd; PANDA Gem-Tracker Subgroup

    2018-02-01

    The P barANDA experiment at FAIR will be performed to investigate different aspects of hadron physics using anti-proton beams interacting with a fixed nuclear target. The experimental setup consists of a complex series of detector components covering a large solid angle. A detector with a gaseous active media equipped with gas electron multiplier (GEM) technique will be employed to measure tracks of charged particles at forward direction in order to achieve a high momentum resolution. In this work, a full setup of the GEM tracking detector has been implemented in the P barANDA Monte Carlo simulation package (PandaRoot) based on the current technical and conceptual design, and the expected performance of the P barANDA GEM-tracking detector has been investigated. Furthermore, material-budget studies in terms of the radiation length of the P barANDA GEM-tracking detector have been made in order to investigate the effect of the detector materials and its associated structures to particle measurements.

  20. Muon flux measurements at the davis campus of the sanford underground research facility with the MAJORANA DEMONSTRATOR veto system

    NASA Astrophysics Data System (ADS)

    Abgrall, N.; Aguayo, E.; Avignone, F. T.; Barabash, A. S.; Bertrand, F. E.; Bradley, A. W.; Brudanin, V.; Busch, M.; Buuck, M.; Byram, D.; Caldwell, A. S.; Chan, Y.-D.; Christofferson, C. D.; Chu, P.-H.; Cuesta, C.; Detwiler, J. A.; Dunagan, C.; Efremenko, Yu.; Ejiri, H.; Elliott, S. R.; Galindo-Uribarri, A.; Gilliss, T.; Giovanetti, G. K.; Goett, J.; Green, M. P.; Gruszko, J.; Guinn, I. S.; Guiseppe, V. E.; Henning, R.; Hoppe, E. W.; Howard, S.; Howe, M. A.; Jasinski, B. R.; Keeter, K. J.; Kidd, M. F.; Konovalov, S. I.; Kouzes, R. T.; LaFerriere, B. D.; Leon, J.; Lopez, A. M.; MacMullin, J.; Martin, R. D.; Massarczyk, R.; Meijer, S. J.; Mertens, S.; Orrell, J. L.; O'Shaughnessy, C.; Overman, N. R.; Poon, A. W. P.; Radford, D. C.; Rager, J.; Rielage, K.; Robertson, R. G. H.; Romero-Romero, E.; Ronquest, M. C.; Schmitt, C.; Shanks, B.; Shirchenko, M.; Snyder, N.; Suriano, A. M.; Tedeschi, D.; Trimble, J. E.; Varner, R. L.; Vasilyev, S.; Vetter, K.; Vorren, K.; White, B. R.; Wilkerson, J. F.; Wiseman, C.; Xu, W.; Yakushev, E.; Yu, C.-H.; Yumatov, V.; Zhitnikov, I.

    2017-07-01

    We report the first measurement of the total muon flux underground at the Davis Campus of the Sanford Underground Research Facility at the 4850 ft level. Measurements were performed using the MAJORANADEMONSTRATOR muon veto system arranged in two different configurations. The measured total flux is (5.31 ± 0.17) ×10-9 μ /s/cm2. Demonstrate a path forward to achieving a background rate at or below 1 count/(ROI-t-y)in the 4-keV region of interest (ROI) around the 2039-keV Q-value for 76Ge ββ(0ν) decay. This is required for tonne-scale germanium-based searches that will probe the inverted-ordering neutrino-mass parameter space for the effective Majorana neutrino mass in ββ(0ν) decay. Show technical and engineering scalability toward a tonne-scale instrument. Perform searches for additional physics beyond the Standard Model, such as dark matter and axions. The MAJORANA Collaboration has designed a modular instrument composed of two cryostats built from ultra-pure electroformed copper, with each cryostat capable of housing over 20 kg of HPGe detectors. The MAJORANADEMONSTRATOR contains 30 kg of detectors fabricated from Ge material enriched to 88% in 76Ge and another 15 kg fabricated from natural Ge (7.8% 76Ge). The modular approach allows us to assemble and optimize each cryostat independently, providing a fast deployment with minimal effect on already-operational detectors.Starting from the innermost cavity, the cryostats are surrounded by a compact graded shield composed of an inner layer of electroformed copper, a layer of commercially sourced C10100 copper, high-purity lead, an active muon veto, borated polyethylene, and pure polyethylene shielding. The cryostats, copper, and lead shielding are enclosed in a radon exclusion box and rest on an over-floor table that has openings for the active muon veto and polyethylene shielding panels situated below the detector. The entire experiment is located in a clean room at the 4850 ft level of SURF. A high-level summary of shield components is shown in Fig. 1.A large fraction of the plastic scintillator panels comprising the active muon-veto system were operated in different configurations at the experimental site during Ge detector constructions and commissioning. We used the resulting data to measure the total muon flux at the Davis Campus at SURF for the first time.

  1. Simulation of Top Quark Pair Production as a Background for Higgs Events at the Compact Muon Solenoid

    NASA Astrophysics Data System (ADS)

    Justus, Christopher

    2005-04-01

    In this study, we simulated top-antitop (tt-bar) quark events at the Compact Muon Solenoid (CMS), an experiment presently being constructed at the Large Hadron Collider in Geneva, Switzerland. The tt-bar process is an important background for Higgs events. We used a chain of software to simulate and reconstruct processes that will occur inside the detector. CMKIN was used to generate and store Monte Carlo Events. OSCAR, a GEANT4 based CMS detector simulator, was used to simulate the CMS detector and how particles would interact with the detector. Next, we used ORCA to simulate the response of the readout electronics at CMS. Last, we used the Jet/MET Root maker to create root files of jets and missing energy. We are now using this software analysis chain to complete a systematic study of initial state radiation at hadron colliders. This study is essential because tt-bar is the main background for the Higgs boson and these processes are extremely sensitive to initial state radiation. Results of our initial state radiation study will be presented. We started this study at the new LHC Physics Center (LPC) located at Fermi National Accelerator Laboratory, and we are now completing the study at the University of Rochester.

  2. Simulating the X-Ray Image Contrast to Set-Up Techniques with Desired Flaw Detectability

    NASA Technical Reports Server (NTRS)

    Koshti, Ajay M.

    2015-01-01

    The paper provides simulation data of previous work by the author in developing a model for estimating detectability of crack-like flaws in radiography. The methodology is being developed to help in implementation of NASA Special x-ray radiography qualification, but is generically applicable to radiography. The paper describes a method for characterizing X-ray detector resolution for crack detection. Applicability of ASTM E 2737 resolution requirements to the model are also discussed. The paper describes a model for simulating the detector resolution. A computer calculator application, discussed here, also performs predicted contrast and signal-to-noise ratio calculations. Results of various simulation runs in calculating x-ray flaw size parameter and image contrast for varying input parameters such as crack depth, crack width, part thickness, x-ray angle, part-to-detector distance, part-to-source distance, source sizes, and detector sensitivity and resolution are given as 3D surfaces. These results demonstrate effect of the input parameters on the flaw size parameter and the simulated image contrast of the crack. These simulations demonstrate utility of the flaw size parameter model in setting up x-ray techniques that provide desired flaw detectability in radiography. The method is applicable to film radiography, computed radiography, and digital radiography.

  3. Pendulum detector testing device

    DOEpatents

    Gonsalves, J.M.

    1997-09-30

    A detector testing device is described which provides consistent, cost-effective, repeatable results. The testing device is primarily constructed of PVC plastic and other non-metallic materials. Sensitivity of a walk-through detector system can be checked by: (1) providing a standard test object simulating the mass, size and material content of a weapon or other contraband, (2) suspending the test object in successive positions, such as head, waist and ankle levels, simulating where the contraband might be concealed on a person walking through the detector system; and (3) swinging the suspended object through each of the positions, while operating the detector system and observing its response. The test object is retained in a holder in which the orientation of the test device or target can be readily changed, to properly complete the testing requirements. 5 figs.

  4. Pendulum detector testing device

    DOEpatents

    Gonsalves, John M.

    1997-01-01

    A detector testing device which provides consistent, cost-effective, repeatable results. The testing device is primarily constructed of PVC plastic and other non-metallic materials. Sensitivity of a walk-through detector system can be checked by: 1) providing a standard test object simulating the mass, size and material content of a weapon or other contraband, 2) suspending the test object in successive positions, such as head, waist and ankle levels, simulating where the contraband might be concealed on a person walking through the detector system; and 3) swinging the suspended object through each of the positions, while operating the detector system and observing its response. The test object is retained in a holder in which the orientation of the test device or target can be readily changed, to properly complete the testing requirements.

  5. Efficient Charge Collection in Coplanar-Grid Radiation Detectors

    NASA Astrophysics Data System (ADS)

    Kunc, J.; Praus, P.; Belas, E.; Dědič, V.; Pekárek, J.; Grill, R.

    2018-05-01

    We model laser-induced transient-current waveforms in radiation coplanar-grid detectors. Poisson's equation is solved by the finite-element method and currents induced by a photogenerated charge are obtained using the Shockley-Ramo theorem. The spectral response on a radiation flux is modeled by Monte Carlo simulations. We show a 10 × improved spectral resolution of the coplanar-grid detector using differential signal sensing. We model the current waveform dependence on the doping, depletion width, diffusion, and detector shielding, and their mutual dependence is discussed in terms of detector optimization. The numerical simulations are successfully compared to experimental data, and further model simplifications are proposed. The space charge below electrodes and a nonhomogeneous electric field on a coplanar-grid anode are found to be the dominant contributions to laser-induced transient-current waveforms.

  6. Use of a Si(Li) detector as β spectrometer.

    PubMed

    Dryák, P; Kovář, P

    2014-05-01

    The aim of this work is to demonstrate the capability of a Si(Li) detector for the measurement of β spectra, despite the energy absorption in air and in the Be window. A simple source holder fixes the source on the symmetry axis at 3mm from the detector window. The β-sources are produced by evaporation on a plastic backing plate. Absorbing materials between the source and the sensitive volume of the detector are 3 mm of air, a Be window, 0.1 μm Si and 20 nm of gold. A model of the detector was created for β spectra simulation using the MCNP 4A code. Experimental spectra of (14)C, (147)Pm, (204)Tl, (90)Sr/(90)Y were compared with simulated spectra. © 2013 Published by Elsevier Ltd.

  7. Air-kerma strength determination of a new directional (103)Pd source.

    PubMed

    Aima, Manik; Reed, Joshua L; DeWerd, Larry A; Culberson, Wesley S

    2015-12-01

    A new directional (103)Pd planar source array called a CivaSheet™ has been developed by CivaTech Oncology, Inc., for potential use in low-dose-rate (LDR) brachytherapy treatments. The array consists of multiple individual polymer capsules called CivaDots, containing (103)Pd and a gold shield that attenuates the radiation on one side, thus defining a hot and cold side. This novel source requires new methods to establish a source strength metric. The presence of gold material in such close proximity to the active (103)Pd region causes the source spectrum to be significantly different than the energy spectra of seeds normally used in LDR brachytherapy treatments. In this investigation, the authors perform air-kerma strength (S(K)) measurements, develop new correction factors for these measurements based on an experimentally verified energy spectrum, and test the robustness of transferring S(K) to a well-type ionization chamber. S(K) measurements were performed with the variable-aperture free-air chamber (VAFAC) at the University of Wisconsin Medical Radiation Research Center. Subsequent measurements were then performed in a well-type ionization chamber. To realize the quantity S(K) from a directional source with gold material present, new methods and correction factors were considered. Updated correction factors were calculated using the MCNP 6 Monte Carlo code in order to determine S(K) with the presence of gold fluorescent energy lines. In addition to S(K) measurements, a low-energy high-purity germanium (HPGe) detector was used to experimentally verify the calculated spectrum, a sodium iodide (NaI) scintillating counter was used to verify the azimuthal and polar anisotropy, and a well-type ionization chamber was used to test the feasibility of disseminating S(K) values for a directional source within a cylindrically symmetric measurement volume. The UW VAFAC was successfully used to measure the S(K) of four CivaDots with reproducibilities within 0.3%. Monte Carlo methods were used to calculate the UW VAFAC correction factors and the calculated spectrum emitted from a CivaDot was experimentally verified with HPGe detector measurements. The well-type ionization chamber showed minimal variation in response (<1.5%) as a function of source positioning angle, indicating that an American Association of Physicists in Medicine (AAPM) Accredited Dosimetry Calibration Laboratory calibrated well chamber would be a suitable device to transfer an S(K)-based calibration to a clinical user. S(K) per well-chamber ionization current ratios were consistent among the four dots measured. Additionally, the measurements and predictions of anisotropy show uniform emission within the solid angle of the VAFAC, which demonstrates the robustness of the S(K) measurement approach. This characterization of a new (103)Pd directional brachytherapy source helps to establish calibration methods that could ultimately be used in the well-established AAPM Task Group 43 formalism. Monte Carlo methods accurately predict the changes in the energy spectrum caused by the fluorescent x-rays produced in the gold shield.

  8. Air-kerma strength determination of a new directional 103Pd source

    PubMed Central

    Reed, Joshua L.; DeWerd, Larry A.; Culberson, Wesley S.

    2015-01-01

    Purpose: A new directional 103Pd planar source array called a CivaSheet™ has been developed by CivaTech Oncology, Inc., for potential use in low-dose-rate (LDR) brachytherapy treatments. The array consists of multiple individual polymer capsules called CivaDots, containing 103Pd and a gold shield that attenuates the radiation on one side, thus defining a hot and cold side. This novel source requires new methods to establish a source strength metric. The presence of gold material in such close proximity to the active 103Pd region causes the source spectrum to be significantly different than the energy spectra of seeds normally used in LDR brachytherapy treatments. In this investigation, the authors perform air-kerma strength (SK) measurements, develop new correction factors for these measurements based on an experimentally verified energy spectrum, and test the robustness of transferring SK to a well-type ionization chamber. Methods: SK measurements were performed with the variable-aperture free-air chamber (VAFAC) at the University of Wisconsin Medical Radiation Research Center. Subsequent measurements were then performed in a well-type ionization chamber. To realize the quantity SK from a directional source with gold material present, new methods and correction factors were considered. Updated correction factors were calculated using the mcnp 6 Monte Carlo code in order to determine SK with the presence of gold fluorescent energy lines. In addition to SK measurements, a low-energy high-purity germanium (HPGe) detector was used to experimentally verify the calculated spectrum, a sodium iodide (NaI) scintillating counter was used to verify the azimuthal and polar anisotropy, and a well-type ionization chamber was used to test the feasibility of disseminating SK values for a directional source within a cylindrically symmetric measurement volume. Results: The UW VAFAC was successfully used to measure the SK of four CivaDots with reproducibilities within 0.3%. Monte Carlo methods were used to calculate the UW VAFAC correction factors and the calculated spectrum emitted from a CivaDot was experimentally verified with HPGe detector measurements. The well-type ionization chamber showed minimal variation in response (<1.5%) as a function of source positioning angle, indicating that an American Association of Physicists in Medicine (AAPM) Accredited Dosimetry Calibration Laboratory calibrated well chamber would be a suitable device to transfer an SK-based calibration to a clinical user. SK per well-chamber ionization current ratios were consistent among the four dots measured. Additionally, the measurements and predictions of anisotropy show uniform emission within the solid angle of the VAFAC, which demonstrates the robustness of the SK measurement approach. Conclusions: This characterization of a new 103Pd directional brachytherapy source helps to establish calibration methods that could ultimately be used in the well-established AAPM Task Group 43 formalism. Monte Carlo methods accurately predict the changes in the energy spectrum caused by the fluorescent x-rays produced in the gold shield. PMID:26632069

  9. High resolution micro-CT of low attenuating organic materials using large area photon-counting detector

    NASA Astrophysics Data System (ADS)

    Kumpová, I.; Vavřík, D.; Fíla, T.; Koudelka, P.; Jandejsek, I.; Jakůbek, J.; Kytýř, D.; Zlámal, P.; Vopálenský, M.; Gantar, A.

    2016-02-01

    To overcome certain limitations of contemporary materials used for bone tissue engineering, such as inflammatory response after implantation, a whole new class of materials based on polysaccharide compounds is being developed. Here, nanoparticulate bioactive glass reinforced gelan-gum (GG-BAG) has recently been proposed for the production of bone scaffolds. This material offers promising biocompatibility properties, including bioactivity and biodegradability, with the possibility of producing scaffolds with directly controlled microgeometry. However, to utilize such a scaffold with application-optimized properties, large sets of complex numerical simulations using the real microgeometry of the material have to be carried out during the development process. Because the GG-BAG is a material with intrinsically very low attenuation to X-rays, its radiographical imaging, including tomographical scanning and reconstructions, with resolution required by numerical simulations might be a very challenging task. In this paper, we present a study on X-ray imaging of GG-BAG samples. High-resolution volumetric images of investigated specimens were generated on the basis of micro-CT measurements using a large area flat-panel detector and a large area photon-counting detector. The photon-counting detector was composed of a 010× 1 matrix of Timepix edgeless silicon pixelated detectors with tiling based on overlaying rows (i.e. assembled so that no gap is present between individual rows of detectors). We compare the results from both detectors with the scanning electron microscopy on selected slices in transversal plane. It has been shown that the photon counting detector can provide approx. 3× better resolution of the details in low-attenuating materials than the integrating flat panel detectors. We demonstrate that employment of a large area photon counting detector is a good choice for imaging of low attenuating materials with the resolution sufficient for numerical simulations.

  10. Adaptive algorithms of position and energy reconstruction in Anger-camera type detectors: experimental data processing in ANTS

    NASA Astrophysics Data System (ADS)

    Morozov, A.; Defendi, I.; Engels, R.; Fraga, F. A. F.; Fraga, M. M. F. R.; Gongadze, A.; Guerard, B.; Jurkovic, M.; Kemmerling, G.; Manzin, G.; Margato, L. M. S.; Niko, H.; Pereira, L.; Petrillo, C.; Peyaud, A.; Piscitelli, F.; Raspino, D.; Rhodes, N. J.; Sacchetti, F.; Schooneveld, E. M.; Solovov, V.; Van Esch, P.; Zeitelhack, K.

    2013-05-01

    The software package ANTS (Anger-camera type Neutron detector: Toolkit for Simulations), developed for simulation of Anger-type gaseous detectors for thermal neutron imaging was extended to include a module for experimental data processing. Data recorded with a sensor array containing up to 100 photomultiplier tubes (PMT) or silicon photomultipliers (SiPM) in a custom configuration can be loaded and the positions and energies of the events can be reconstructed using the Center-of-Gravity, Maximum Likelihood or Least Squares algorithm. A particular strength of the new module is the ability to reconstruct the light response functions and relative gains of the photomultipliers from flood field illumination data using adaptive algorithms. The performance of the module is demonstrated with simulated data generated in ANTS and experimental data recorded with a 19 PMT neutron detector. The package executables are publicly available at http://coimbra.lip.pt/~andrei/

  11. Characterizing scintillator detector response for correlated fission experiments with MCNP and associated packages

    DOE PAGES

    Andrews, M. T.; Rising, M. E.; Meierbachtol, K.; ...

    2018-06-15

    Wmore » hen multiple neutrons are emitted in a fission event they are correlated in both energy and their relative angle, which may impact the design of safeguards equipment and other instrumentation for non-proliferation applications. The most recent release of MCNP 6 . 2 contains the capability to simulate correlated fission neutrons using the event generators CGMF and FREYA . These radiation transport simulations will be post-processed by the detector response code, DRiFT , and compared directly to correlated fission measurements. DRiFT has been previously compared to single detector measurements, its capabilities have been recently expanded with correlated fission simulations in mind. Finally, this paper details updates to DRiFT specific to correlated fission measurements, including tracking source particle energy of all detector events (and non-events), expanded output formats, and digitizer waveform generation.« less

  12. X-Ray Detector Simulations - Oral Presentation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tina, Adrienne

    2015-08-20

    The free-electron laser at LCLS produces X-Rays that are used in several facilities. This light source is so bright and quick that we are capable of producing movies of objects like proteins. But making these movies would not be possible without a device that can detect the X-Rays and produce images. We need X-Ray cameras. The challenges LCLS faces include the X-Rays’ high repetition rate of 120 Hz, short pulses that can reach 200 femto-seconds, and extreme peak brightness. We need detectors that are compatible with this light source, but before they can be used in the facilities, they mustmore » first be characterized. My project was to do just that, by making a computer simulation program. My presentation discusses the individual detectors I simulated, the details of my program, and how my project will help determine which detector is most useful for a specific experiment.« less

  13. Characterizing scintillator detector response for correlated fission experiments with MCNP and associated packages

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Andrews, M. T.; Rising, M. E.; Meierbachtol, K.

    Wmore » hen multiple neutrons are emitted in a fission event they are correlated in both energy and their relative angle, which may impact the design of safeguards equipment and other instrumentation for non-proliferation applications. The most recent release of MCNP 6 . 2 contains the capability to simulate correlated fission neutrons using the event generators CGMF and FREYA . These radiation transport simulations will be post-processed by the detector response code, DRiFT , and compared directly to correlated fission measurements. DRiFT has been previously compared to single detector measurements, its capabilities have been recently expanded with correlated fission simulations in mind. Finally, this paper details updates to DRiFT specific to correlated fission measurements, including tracking source particle energy of all detector events (and non-events), expanded output formats, and digitizer waveform generation.« less

  14. Position, Orientation and Velocity Detection of Unmanned Underwater Vehicles (UUVs) Using an Optical Detector Array

    PubMed Central

    Pe’eri, Shachak; Thein, May-Win; Rzhanov, Yuri; Celikkol, Barbaros; Swift, M. Robinson

    2017-01-01

    This paper presents a proof-of-concept optical detector array sensor system to be used in Unmanned Underwater Vehicle (UUV) navigation. The performance of the developed optical detector array was evaluated for its capability to estimate the position, orientation and forward velocity of UUVs with respect to a light source fixed in underwater. The evaluations were conducted through Monte Carlo simulations and empirical tests under a variety of motion configurations. Monte Carlo simulations also evaluated the system total propagated uncertainty (TPU) by taking into account variations in the water column turbidity, temperature and hardware noise that may degrade the system performance. Empirical tests were conducted to estimate UUV position and velocity during its navigation to a light beacon. Monte Carlo simulation and empirical results support the use of the detector array system for optics based position feedback for UUV positioning applications. PMID:28758936

  15. Comparison of different width detector on the gross tumor volume delineation of the solitary pulmonary lesion.

    PubMed

    Shang, Dongping; Yue, Jinbo; Li, Jianbin; Duan, Jinghao; Yin, Yong; Yu, Jinming

    2017-01-01

    To explore the impact of different width detector on the volume and geometric position of gross tumor volume (GTV) of the solitary pulmonary lesion (SPL), as well as the impact on scanning time and radiation dose during the simulation. Twenty-three patients with SPL underwent three-dimensional computed tomography (3DCT) simulation using different width detector, followed by four-dimensional computed tomography (4DCT) scans. GTV16 and GTV4 derived from different width detectors were compared with internal gross tumor volume (IGTV) generated from 4DCT on the volume and geometric position. Fourteen patients with lesions located in the upper lobe were defined as Group A and nine patients in the middle or lower lobe were defined as Group B. The scanning time and radiation dose during the simulation with the different width detector were compared as well. The volumes of IGTV, GTV16, and GTV4 in Group A were 13.86 ± 14.42 cm3, 11.88 ± 11.93 cm3, and 11.64 ± 12.88 cm3, respectively, and the corresponding volumes in Group B were 12.84 ± 11.48 cm3, 6.90 ± 6.63 cm3, and 7.22 ± 7.15 cm3, respectively. No difference was found between GTV16 and GTV4 in Groups A and B (PA = 0.11, PB = 0.86). Either GTV16 or GTV4 was smaller than IGTV (P16 = 0.001, P4 = 0.000). The comparison of the centroidal positions in x, y, and z directions for GTV16, GTV4, and IGTV showed no significant difference both in Groups A and B (Group A: Px = 0.19, Py = 0.14, Pz = 0.47. Group B: Px = 0.09, Py = 0.90, Pz = 0.90). The scanning time was shorter and radiation dose patient received was lower using 16 × 1.5 mm detector combination than 4 × 1.5 mm detector (P = 0.000). Different width detector had no impact on the volume and geometric position of GTV of SPL during 3DCT simulation. Using wide detector would save time and decrease radiation dose compared with the narrow one. 3DCT simulation using either 16 × 1.5 mm detector or 4 × 1.5 mm detector could not cover all tumor motion information that 4DCT offered under free breathing conditions.

  16. Quantification of the Spatial Distribution of Radionuclides in Field Lysimeters with a Collimated High-Resolution Gamma-Ray Spectrometer

    NASA Astrophysics Data System (ADS)

    Erdmann, Bryan James

    The objective of this work is to quantify the one-dimensional spatial distribution of radionuclides in field lysimeters from the Radionuclide Field Lysimeter Experiment (RadFLEX) facility at the Savannah River Nationals Laboratory (SRNL). The lysimeters, containing 137Cs, 60Co, 133Ba and 152Eu incorporated either into solid wasteforms (Portland cement and reducing grout) or introduced into soil via a filter paper wasteform, were weathered for three to four years. The initial contaminant activities range from 4.0 to 9.0 MBq for the cementitious wasteforms and 0.25 to 0.47 MBq for the filter paper wasteform. An analytical method was developed to perform non-destructive measurements to quantify the spatial distributions measured in field lysimeters. This method provides an alternative to traditional destructive techniques to determine the spatial distribution of activity. This non-destructive method also allows for multiple scans to be performed periodically. Observing how these distributions change with time would improve modeling transport parameters. The detection system consists of a collimated high-purity germanium (HPGe) radiation detector coupled with a linear translational table. A lead collimator is used to achieve spatial resolution as high as 0.25 cm. The lysimeters are positioned relative to the detector using a linear translation stage that can move vertically via a computercontrolled stepping motor. A user control interface was developed with National Instruments LabVIEWRTM that synchronizes the data acquisition from the radiation detector with the lysimeter movement and positioning thus allowing the lysimeter scans to be automated. The detection efficiency of the system was investigated using two methods. Europium-152 is an ideal candidate for calibration source due to its multiple gamma-ray emissions across a wide range of energies. One method uses a 152Eu point source as the calibration standard while the other method uses the 152Eu within the lysimeter systems themselves as the calibration standard. These methods show that system geometry and source distribution are the key factors influencing the detection efficiency. This suggest that to reduce the impact from the source distribution and geometry variability within a volume, that lysimeters be rotated during measurements. These scans showed downward mobility of 60Co and 133Ba when the radionuclides were incorporated directly into the Savannah River Site (SRS) soil via the filter paper wasteform. When radionuclides were incorporated into the cementitious wasteforms positioned in the SRSS soil, 137Cs exhibited both upward and downward dispersion while the other radionuclides showed no movement. This dispersion was more significant for the Portland cement than the reducing grout wasteform. In the case of the filter paper wasteform, 137Cs mobility was greatly reduced. This suggests the presence of a cementitious wasteform enhances 137Cs mobility. The movement of 137Cs from the solid wasteform was modelled using a retarded diffusion model. Retardation factors for 137Cs are determined to range from approximately 700-2500 for Portland cement, 1500-4000 for reducing grout, and up to 2500-8000 the filter paper wasteform. Numerical simulations were run to investigate the hypothesis that ions released from the wasteforms compete for sorption sites in the SRS soil, enhancing the mobility of 137Cs. These simulations suggest ion-competition could be a factor, but more data is needed to explore this mechanism for Cs+ transport. Understanding radionuclide movement in the environment is important for informing strategies used for waste management and disposal.

  17. Characterization of cartridge filters from the IEA-R1 Nuclear Reactor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    The management of radioactive waste ensures safety to human health and the environment nowadays and for the future, without overwhelming the upcoming generations. The primary characterization of radioactive waste is one of the main steps in the management of radioactive waste. This step permits to choose the best treatment for the radioactive waste before forwarding it to its final disposal. The aim of the present work is the primary characterization of cartridge filters from the IEA-R1 nuclear reactor utilizing gamma-ray spectrometry, and the method of Monte Carlo for calibration. The IEA-R1 is located in the Nuclear and Energy Research Institutemore » (IPEN - CNEN) in the city of Sao Paulo, Brazil. Cartridge filters are used for purification of the cooling water that is pumped through the core of the pool type nuclear research reactors. Once worn out, these filters are replaced and then become radioactive waste. Determination of the radioactive inventory is of paramount importance in the management of such radioactive waste, and one of the main methods for doing so is the gamma-ray spectrometry, which can identify and quantify high energy photon emitters. The technique chosen for the characterization of radioactive waste in the present work is the gamma-ray spectrometry with High purity Germanium (HPGe) detectors. From the energy identified in the experimental spectrum, three radioisotopes were identified in the cartridge filter: {sup 108m}Ag, {sup 110m}Ag, {sup 60}Co. For the estimated activity of the filter, the calibration in efficiency was made utilizing the MCNP4C code of the Monte Carlo method. Such method was chosen because there is no standard source available in the same geometry of the cartridge filter, therefore a simulation had to be developed in order to reach a calibration equation, necessary to estimate the activity of the radioactive waste. The results presented an activity value in the order of MBq for all radioisotopes. (authors)« less

  18. Sensitivity booster for DOI-PET scanner by utilizing Compton scattering events between detector blocks

    NASA Astrophysics Data System (ADS)

    Yoshida, Eiji; Tashima, Hideaki; Yamaya, Taiga

    2014-11-01

    In a conventional PET scanner, coincidence events are measured with a limited energy window for detection of photoelectric events in order to reject Compton scatter events that occur in a patient, but Compton scatter events caused in detector crystals are also rejected. Scatter events within the patient causes scatter coincidences, but inter crystal scattering (ICS) events have useful information for determining an activity distribution. Some researchers have reported the feasibility of PET scanners based on a Compton camera for tracing ICS into the detector. However, these scanners require expensive semiconductor detectors for high-energy resolution. In the Anger-type block detector, single photons interacting with multiple detectors can be obtained for each interacting position and complete information can be gotten just as for photoelectric events in the single detector. ICS events in the single detector have been used to get coincidence, but single photons interacting with multiple detectors have not been used to get coincidence. In this work, we evaluated effect of sensitivity improvement using Compton kinetics in several types of DOI-PET scanners. The proposed method promises to improve the sensitivity using coincidence events of single photons interacting with multiple detectors, which are identified as the first interaction (FI). FI estimation accuracy can be improved to determine FI validity from the correlation between Compton scatter angles calculated on the coincidence line-of-response. We simulated an animal PET scanner consisting of 42 detectors. Each detector block consists of three types of scintillator crystals (LSO, GSO and GAGG). After the simulation, coincidence events are added as information for several depth-of-interaction (DOI) resolutions. From the simulation results, we concluded the proposed method promises to improve the sensitivity considerably when effective atomic number of a scintillator is low. Also, we showed that FI estimate accuracy is improved, as DOI resolution is high.

  19. Simulation of gamma-ray spectra for a variety of user-specified detector designs

    NASA Technical Reports Server (NTRS)

    Rester, A. C., Jr.

    1994-01-01

    The gamma-ray spectrum simulation program BSIMUL was designed to allow the operator to follow the path of a gamma-ray through a detector, shield and collimator whose dimensions are entered by the operator. It can also be used to simulate spectra that would be generated by a detector. Several improvements have been made to the program within the last few months. The detector, shield and collimator dimensions can now be entered through an interactive menu whose options are discussed below. In addition, spectra containing more than one gamma-ray energy can now be generated with the menu - for isotopes listed in the program. Adding isotopes to the main routine is also quite easy. Subroutines have been added to enable the operator to specify the material and dimensions of a collimator. This report details the progress made in simulating gamma-ray spectra for a variety of user-specified detector designs. In addition, a short discussion of work done in the related areas of pulse shape analysis and the spectral analysis is included. The pulse shape analysis and spectral analysis work is being performed pursuant to the requirements of contract F-94-C-0006, for the Advanced Research Projects Agency and the U.S. Air Force.

  20. Optical detector calibrator system

    NASA Technical Reports Server (NTRS)

    Strobel, James P. (Inventor); Moerk, John S. (Inventor); Youngquist, Robert C. (Inventor)

    1996-01-01

    An optical detector calibrator system simulates a source of optical radiation to which a detector to be calibrated is responsive. A light source selected to emit radiation in a range of wavelengths corresponding to the spectral signature of the source is disposed within a housing containing a microprocessor for controlling the light source and other system elements. An adjustable iris and a multiple aperture filter wheel are provided for controlling the intensity of radiation emitted from the housing by the light source to adjust the simulated distance between the light source and the detector to be calibrated. The geared iris has an aperture whose size is adjustable by means of a first stepper motor controlled by the microprocessor. The multiple aperture filter wheel contains neutral density filters of different attenuation levels which are selectively positioned in the path of the emitted radiation by a second stepper motor that is also controlled by the microprocessor. An operator can select a number of detector tests including range, maximum and minimum sensitivity, and basic functionality. During the range test, the geared iris and filter wheel are repeatedly adjusted by the microprocessor as necessary to simulate an incrementally increasing simulated source distance. A light source calibration subsystem is incorporated in the system which insures that the intensity of the light source is maintained at a constant level over time.