Sample records for simultaneous venous sampling

  1. Arterial and venous plasma levels of bupivacaine following epidural and intercostal nerve blocks.

    PubMed

    Moore, D C; Mather, L E; Bridenbaugh, P O; Bridenbaugh, L D; Balfour, R I; Lysons, D F; Horton, W G

    1976-07-01

    Arterial and peripheral venous plasma levels of bupivacaine were determined in 30 patients following epidural anesthesia using 150 and 225 mg, as well as following intercostal nerve block with 400 mg. Arterial levels were consistently higher than levels in simultaneously sampled venous blood, and the highest levels occurred with bilateral intercostal nerve block. No evidence of systemic toxicity was observed. The results suggest that bupivacaine may have a wider margin of safety in man than is now stated.

  2. Dried blood spot measurement: application in tacrolimus monitoring using limited sampling strategy and abbreviated AUC estimation.

    PubMed

    Cheung, Chi Yuen; van der Heijden, Jaques; Hoogtanders, Karin; Christiaans, Maarten; Liu, Yan Lun; Chan, Yiu Han; Choi, Koon Shing; van de Plas, Afke; Shek, Chi Chung; Chau, Ka Foon; Li, Chun Sang; van Hooff, Johannes; Stolk, Leo

    2008-02-01

    Dried blood spot (DBS) sampling and high-performance liquid chromatography tandem-mass spectrometry have been developed in monitoring tacrolimus levels. Our center favors the use of limited sampling strategy and abbreviated formula to estimate the area under concentration-time curve (AUC(0-12)). However, it is inconvenient for patients because they have to wait in the center for blood sampling. We investigated the application of DBS method in tacrolimus level monitoring using limited sampling strategy and abbreviated AUC estimation approach. Duplicate venous samples were obtained at each time point (C(0), C(2), and C(4)). To determine the stability of blood samples, one venous sample was sent to our laboratory immediately. The other duplicate venous samples, together with simultaneous fingerprick blood samples, were sent to the University of Maastricht in the Netherlands. Thirty six patients were recruited and 108 sets of blood samples were collected. There was a highly significant relationship between AUC(0-12), estimated from venous blood samples, and fingerprick blood samples (r(2) = 0.96, P < 0.0001). Moreover, there was an excellent correlation between whole blood venous tacrolimus levels in the two centers (r(2) = 0.97; P < 0.0001). The blood samples were stable after long-distance transport. DBS sampling can be used in centers using limited sampling and abbreviated AUC(0-12) strategy as drug monitoring.

  3. Prior exercise alters the difference between arterialised and venous glycaemia: implications for blood sampling procedures.

    PubMed

    Edinburgh, Robert M; Hengist, Aaron; Smith, Harry A; Betts, James A; Thompson, Dylan; Walhin, Jean-Philippe; Gonzalez, Javier T

    2017-05-01

    Oral glucose tolerance and insulin sensitivity are common measures, but are determined using various blood sampling methods, employed under many different experimental conditions. This study established whether measures of oral glucose tolerance and oral glucose-derived insulin sensitivity (insulin sensitivity indices; ISI) differ when calculated from venous v. arterialised blood. Critically, we also established whether any differences between sampling methods are consistent across distinct metabolic conditions (after rest v. after exercise). A total of ten healthy men completed two trials in a randomised order, each consisting of a 120-min oral glucose tolerance test (OGTT), either at rest or post-exercise. Blood was sampled simultaneously from a heated hand (arterialised) and an antecubital vein of the contralateral arm (venous). Under both conditions, glucose time-averaged AUC was greater from arterialised compared with venous plasma but importantly, this difference was larger after rest relative to after exercise (0·99 (sd 0·46) v. 0·56 (sd 0·24) mmol/l, respectively; P<0·01). OGTT-derived ISIMatsuda and ISICederholm were lower when calculated from arterialised relative to venous plasma and the arterialised-venous difference was greater after rest v. after exercise (ISIMatsuda: 1·97 (sd 0·81) v. 1·35 (sd 0·57) arbitrary units (au), respectively; ISICederholm : 14·76 (sd 7·83) v. 8·70 (sd 3·95) au, respectively; both P<0·01). Venous blood provides lower postprandial glucose concentrations and higher estimates of insulin sensitivity, compared with arterialised blood. Most importantly, these differences between blood sampling methods are not consistent after rest v. post-exercise, preventing standardised venous-to-arterialised corrections from being readily applied.

  4. Assessing vitamin D nutritional status: Is capillary blood adequate?

    PubMed

    Jensen, M E; Ducharme, F M; Théorêt, Y; Bélanger, A-S; Delvin, E

    2016-06-01

    Venous blood is the usual sample for measuring various biomarkers, including 25-hydroxyvitamin D (25OHD). However, it can prove challenging in infants and young children. Hence the finger-prick capillary collection is an alternative, being a relatively simple procedure perceived to be less invasive. We elected to validate the use of capillary blood sampling for 25OHD quantification by liquid chromatography tandem-mass spectrometry (LC/MS-MS). Venous and capillary blood samples were simultaneously collected from 15 preschool-aged children with asthma 10days after receiving 100,000IU of vitamin-D3 or placebo and 20 apparently healthy adult volunteers. 25OHD was measured by an in-house LC/MS-MS method. The venous 25OHD values varied between 23 and 255nmol/l. The venous and capillary blood total 25OHD concentrations highly correlated (r(2)=0.9963). The mean difference (bias) of capillary blood 25OHD compared to venous blood was 2.0 (95% CI: -7.5, 11.5) nmol/l. Our study demonstrates excellent agreement with no evidence of a clinically important bias between venous and capillary serum 25OHD concentrations measured by LC/MS-MS over a wide range of values. Under those conditions, capillary blood is therefore adequate for the measurement of 25OHD. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Combined Recirculatory-compartmental Population Pharmacokinetic Modeling of Arterial and Venous Plasma S(+) and R(-) Ketamine Concentrations.

    PubMed

    Henthorn, Thomas K; Avram, Michael J; Dahan, Albert; Gustafsson, Lars L; Persson, Jan; Krejcie, Tom C; Olofsen, Erik

    2018-05-16

    The pharmacokinetics of infused drugs have been modeled without regard for recirculatory or mixing kinetics. We used a unique ketamine dataset with simultaneous arterial and venous blood sampling, during and after separate S(+) and R(-) ketamine infusions, to develop a simplified recirculatory model of arterial and venous plasma drug concentrations. S(+) or R(-) ketamine was infused over 30 min on two occasions to 10 healthy male volunteers. Frequent, simultaneous arterial and forearm venous blood samples were obtained for up to 11 h. A multicompartmental pharmacokinetic model with front-end arterial mixing and venous blood components was developed using nonlinear mixed effects analyses. A three-compartment base pharmacokinetic model with additional arterial mixing and arm venous compartments and with shared S(+)/R(-) distribution kinetics proved superior to standard compartmental modeling approaches. Total pharmacokinetic flow was estimated to be 7.59 ± 0.36 l/min (mean ± standard error of the estimate), and S(+) and R(-) elimination clearances were 1.23 ± 0.04 and 1.06 ± 0.03 l/min, respectively. The arm-tissue link rate constant was 0.18 ± 0.01 min and the fraction of arm blood flow estimated to exchange with arm tissue was 0.04 ± 0.01. Arterial drug concentrations measured during drug infusion have two kinetically distinct components: partially or lung-mixed drug and fully mixed-recirculated drug. Front-end kinetics suggest the partially mixed concentration is proportional to the ratio of infusion rate and total pharmacokinetic flow. This simplified modeling approach could lead to more generalizable models for target-controlled infusions and improved methods for analyzing pharmacokinetic-pharmacodynamic data.

  6. Ammonia concentrations in arterial blood, venous blood, and cerebrospinal fluid of dogs with and without congenital extrahepatic portosystemic shunts.

    PubMed

    Or, Matan; Devriendt, Nausikaa; Kitshoff, Adriaan M; Peremans, Kathelijne; Vandermeulen, Eva; Paepe, Dominique; Polis, Ingeborgh; Martlé, Valentine; de Rooster, Hilde

    2017-11-01

    OBJECTIVE To compare ammonia concentrations in arterial blood, venous blood, and CSF samples of dogs with and without extrahepatic portosystemic shunts (EHPSS). ANIMALS 19 dogs with congenital EHPSS and 6 healthy control dogs. PROCEDURES All dogs underwent a physical examination and then were anesthetized for transsplenic portal scintigraphy to confirm the presence or absence of EHPSS. While dogs were anesthetized, arterial and venous blood samples and a CSF sample were simultaneously collected for determination of ammonia concentration, which was measured by use of a portable blood ammonia analyzer (device A) and a nonportable biochemical analyzer (device B). Results were compared between dogs with EHPSS and control dogs. RESULTS Arterial, venous, and CSF ammonia concentrations for dogs with EHPSS were significantly greater than those for control dogs. For dogs with EHPSS, ammonia concentrations in both arterial and venous blood samples were markedly increased from the reference range. There was a strong positive correlation between arterial and venous ammonia concentrations and between blood (arterial or venous) and CSF ammonia concentrations. CONCLUSIONS AND CLINICAL RELEVANCE Results indicated that blood and CSF ammonia concentrations in dogs with EHPSS were greater than those for healthy dogs and were strongly and positively correlated, albeit in a nonlinear manner. This suggested that the permeability of the blood-brain barrier to ammonia may be abnormally increased in dogs with EHPSS, but further investigation of the relationship between blood or CSF ammonia concentration and clinical signs of hepatic encephalopathy or the surgical outcome for dogs with EHPSS is warranted.

  7. [Venous tone of the limbs. Methods and comparison of 2 areas].

    PubMed

    Journo, H; London, G; Pannier, B; Safar, M

    1989-07-01

    The limb venous tone, index of local venous compliance, was studied with mercury strain gauge plethysmography on 28 male normal subjects (40 +/- 17 years, +/- SD) simultaneously on upper and lower limbs. Measurements were done after 20 mn rest in supine position. Venous tone (VT) equals the slope of the pressure-volume curve established by simultaneous recording of the forearm and calf relative volumes for successive steps of pressure lower than or equal to 30 mmHg. Limb venous capacitance was expressed by means of the maximal limb relative volume (V30) reached for a pressure of 30 mmHg applied through cuffs in standardized conditions. The upper limb venous tone was greater than the lower limb venous tone: 24.3 +/- 8.2 mmHg/ml/100 vs 17.5 +/- 7.9 mmHg/ml/100, p = 0.001. V30 was greater in lower limb than in upper limb: 1.5 +/- 0.5 ml/100 vs 1.1 +/- 0.4 ml/100, p = 0.001. In conclusion, it appears that upper and lower limbs venous distensibility and capacitance are different. They are greater in the lower limb in baseline conditions. Thus simultaneous studies of both these limb venous systems seems important for physiological experiments because of their baseline differences.

  8. [Concordance between central venous and arterial blood gases in post-surgical myocardial revascularization patients in stable condition].

    PubMed

    Santos-Martínez, Luis Efren; Guevara-Carrasco, Marlene; Naranjo-Ricoy, Guillermo; Baranda-Tovar, Francisco Martín; Moreno-Ruíz, Luis Antonio; Herrera-Velázquez, Marco Antonio; Magaña-Serrano, José Antonio; Valencia-Sánchez, Jesús Salvador; Calderón-Abbo, Moisés Cutiel

    2014-01-01

    The concordance between the parameters of arterial and central venous blood gases has not been defined yet. We studied the concordance between both parameters in post-surgical myocardial revascularization patients in stable condition. Consecutive subjects were studied in a cross-sectional design. The position of the central venous catheter was performed and simultaneously we obtained arterial and central venous blood samples prior to discharge from the intensive care unit. Data are expressed according to Bland-Altman statistical method and the intraclass correlation coefficient. Statistical result was accepted at P<.05. Two hundred and six samples were studied of 103 post-surgical patients, pH and lactate had a mean difference (limits of agreement) 0.029±0.048 (-0018, 0.077) and -0.12±0.22 (-0.57, 0.33) respectively. The magnitude of the intraclass correlation coefficient was 0.904 and 0.943 respectively. The values related to oxygen pressure were 27.86±6.08 (15.9, 39.8) and oxygen saturation 33.02±6.13 (21, 45), with magnitude of 0.258 and 0.418 respectively. The best matching parameters between arterial and central venous blood samples were pH and lactate. Copyright © 2013 Instituto Nacional de Cardiología Ignacio Chávez. Published by Masson Doyma México S.A. All rights reserved.

  9. Simultaneous detection of colonic epithelial cells in portal venous and peripheral blood during colorectal cancer surgery.

    PubMed

    Tien, Yu-Wen; Lee, Po-Huang; Wang, Shih-Ming; Hsu, Su-Ming; Chang, King-Jen

    2002-01-01

    This study was designed to show, in certain patients, that colonic epithelial cells can be present in peripheral blood while absent in portal venous blood. The circulating colorectal epithelial cells were detected by a reverse transcriptase-polymerase chain reaction assay, which involved amplifying guanylyl cyclase C transcripts. Portal venous and peripheral blood samples were obtained at intervals from 58 patients undergoing colorectal cancer surgery. Circulating colonic epithelial cells were more frequently detected in portal venous blood than in peripheral blood only before mobilization of the tumor-bearing colon segment in patients with tumors of Stage B. In five other patients, before mobilization of their tumor-bearing colon segments, and in another three patients, during the mobilization, colorectal epithelial cells were detected in peripheral blood but not in portal venous blood. These eight patients had Stage C or D tumors. In 8 of 58 patients, colorectal epithelial cells were detected in peripheral but not in portal venous blood. Metastatic deposits in lymphatic vessels or liver might be the source of these cells.

  10. Venous blood provides lower GLP-1 concentrations than arterialised blood in the postprandial, but not fasted state: Consequences of sampling methods.

    PubMed

    Chen, Yung-Chih; Edinburgh, Robert M; Hengist, Aaron; Smith, Harry A; Walhin, Jean-Philippe; Betts, James A; Thompson, Dylan; Gonzalez, Javier T

    2018-06-27

    What is the central question of this study? Glucagon-like peptide-1 (GLP-1) is an important obesity/diabetes target, with effects dependent on circulating GLP-1 concentrations. Peripheral tissues extract GLP-1, therefore sampling venous versus arterialised blood may provide different GLP-1 concentrations. This study examined whether arterialisation alters GLP-1 concentrations during fasting and feeding. What is the main finding and its importance? This study demonstrates that venous blood provides lower postprandial, but not fasting, GLP-1 concentrations versus arterialised blood. Therefore, when accurate assessment of postprandial peripheral availability of GLP-1 is required, blood sampling methods should be carefully considered, clearly reported, and arterialisation is recommended. Glucagon-like peptide-1 (GLP-1) displays concentration-dependent effects on metabolism, appetite and angiogenesis, so accurate determination of circulating GLP-1 concentrations is important. This study compared GLP-1 concentrations in venous versus arterialised blood under both fasted and fed conditions. Venous and arterialised blood samples were simultaneously drawn from ten, young, healthy men before, and 30, 60 and 120 min after, ingestion of 75 g glucose. Plasma GLP-1 concentrations increased in response to glucose ingestion (time effect: p < 0.01) and to a lesser extend in venous versus arterialised plasma (time x arterialisation interaction: p < 0.01). Accordingly, the plasma incremental area under the curve was lower in venous versus arterialised plasma (974 ± 88 versus 1214 ± 115 pmol·L x 120 min -1 , respectively, p = 0.049). In the postprandial state, there was a positive relationship between arterialised GLP-1 concentrations and the venous-arterialised difference in GLP-1 concentrations (r 2  = 0.51; p < 0.01). Both arterialised and venous peak GLP-1 concentrations showed positive relationships with peak arterialised insulin concentrations (both r 2  > 0.6, p < 0.01). Venous sampling results in lower concentrations of GLP-1 in the postprandial, but not the fasted state compared to arterialised blood. This absolute difference is biologically meaningful and is magnified when GLP-1 availability is high. Therefore, sampling from arterialised blood may provide a better chance of detecting small differences in postprandial GLP-1 availability with interventions and if absolute GLP-1 concentrations are of interest, the blood sampling method should be carefully considered and clearly reported. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  11. Amyloid-β efflux from the CNS into the plasma

    PubMed Central

    Roberts, Kaleigh Filisa; Elbert, Donald L.; Kasten, Tom P.; Patterson, Bruce W.; Sigurdson, Wendy C.; Connors, Rose E.; Ovod, Vitaliy; Munsell, Ling Y.; Mawuenyega, Kwasi G.; Miller-Thomas, Michelle M.; Moran, Christopher J.; Cross, Dewitte T.; Derdeyn, Colin P.; Bateman, Randall J.

    2015-01-01

    Objective The aim of this study was to measure the flux of amyloid-β (Aβ) across the human cerebral capillary bed in order to determine if transport into the blood is a significant mechanism of clearance for Aβ produced in the central nervous system (CNS). Methods Time-matched blood samples were simultaneously collected from a cerebral vein (including the sigmoid sinus, inferior petrosal sinus, and the internal jugular vein), femoral vein, and radial artery of patients undergoing Inferior Petrosal Sinus Sampling (IPSS). For each plasma sample, Aβ concentration was assessed by three assays and the venous to arterial Aβ concentration ratios were determined. Results Aβ concentration was increased by ~7.5% in venous blood leaving the CNS capillary bed compared to arterial blood, indicating efflux from the CNS into the peripheral blood (p < 0.0001). There was no difference in peripheral venous Aβ concentration compared to arterial blood concentration. Interpretation Our results are consistent with clearance of CNS-derived Aβ into the venous blood supply with no increase from a peripheral capillary bed. Modeling these results suggests that direct transport of Aβ across the blood-brain barrier accounts for ~25% of Aβ clearance, and reabsorption of cerebrospinal fluid Aβ accounts for ~25% of the total CNS Aβ clearance in humans. PMID:25205593

  12. Access technique and its problems in parenteral nutrition – Guidelines on Parenteral Nutrition, Chapter 9

    PubMed Central

    Jauch, K. W.; Schregel, W.; Stanga, Z.; Bischoff, S. C.; Braß, P.; Hartl, W.; Muehlebach, S.; Pscheidl, E.; Thul, P.; Volk, O.

    2009-01-01

    Catheter type, access technique, and the catheter position should be selected considering to the anticipated duration of PN aiming at the lowest complication risks (infectious and non-infectious). Long-term (>7–10 days) parenteral nutrition (PN) requires central venous access whereas for PN <3 weeks percutaneously inserted catheters and for PN >3 weeks subcutaneous tunnelled catheters or port systems are appropriate. CVC (central venous catheter) should be flushed with isotonic NaCl solution before and after PN application and during CVC occlusions. Strict indications are required for central venous access placement and the catheter should be removed as soon as possible if not required any more. Blood samples should not to be taken from the CVC. If catheter infection is suspected, peripheral blood-culture samples and culture samples from each catheter lumen should be taken simultaneously. Removal of the CVC should be carried out immediately if there are pronounced signs of local infection at the insertion site and/or clinical suspicion of catheter-induced sepsis. In case PN is indicated for a short period (max. 7–10 days), a peripheral venous access can be used if no hyperosmolar solutions (>800 mosm/L) or solutions with a high titration acidity or alkalinity are used. A peripheral venous catheter (PVC) can remain in situ for as long as it is clinically required unless there are signs of inflammation at the insertion site. PMID:20049083

  13. Analysis of intraosseous samples in endotoxemic shock--an experimental study in the anaesthetised pig.

    PubMed

    Strandberg, G; Larsson, A; Lipcsey, M; Berglund, L; Eriksson, M

    2014-03-01

    Intraosseous (IO) access is used in emergency situations to allow rapid initiation of treatment. IO access is also sometimes used for blood sampling, although data on accuracy of such sampling in critical illness are limited. There is also a potential risk that bone marrow fragments in IO samples may damage laboratory equipment. It is ethically questionable to perform a simultaneous comparison between IO and arterial/venous sampling in critically ill humans. We have, thus, studied the analytical performance of IO sampling in a porcine septic shock model using a cartridge-based analyser. Eight pigs with endotoxin-induced septic shock were sampled hourly for 6 h, and analysed for blood gases, acid base status, haemoglobin, glucose and lactate using point of care instruments. Samples were taken from three IO cannulae (tibia bilaterally, one with infusion, and humerus), one arterial and one venous. An interaction test was used to assess changes in agreement between methods over time. Bland–Altman plots were constructed to study bias between methods. There were, to a varying extent, differences between IO and arterial/venous levels for all studied variables, but agreement did not change significantly during the experiment. A general finding was a large dispersion of differences between methods. IO sample values should be treated with caution in this setting but may add useful information to the clinical picture. The tibia or humerus may be used for sampling. IO infusion decreases agreement, thus sampling during infusion should be avoided.

  14. Arterial and venous plasma levels of bupivacaine following peripheral nerve blocks.

    PubMed

    Moore, D C; Mather, L E; Bridenbaugh, L D; Balfour, R I; Lysons, D F; Horton, W G

    1976-01-01

    Mean arterial plasma (MAP) and peripheral mean venous plasma (MVP) levels of bupivacaine were ascertained in 3 groups of 10 patients each for: (1) intercostal nerve block, 400 mg; (2) block of the sciatic, femoral, and lateral femoral cutaneous nerves, with or without block of the obturator nerve, 400 mg; and (3) supraclavicular brachial plexus block, 300 mg. MAP levels were consistently higher than simultaneously sampled MVP levels, the highest levels occurring from bilateral intercostal nerve block. No evidence of systemic toxicity was observed. The results suggest that bupivacaine has a much wider margin of safety in humans than is now stated.

  15. Accuracy of capillary blood 3-β-hydroxybutyrate determination for the detection and treatment of canine diabetic ketoacidosis.

    PubMed

    Bresciani, Francesca; Pietra, Marco; Corradini, Sara; Giunti, Massimo; Fracassi, Federico

    2014-01-01

    In human medicine, diagnosis of diabetic ketoacidosis (DKA) is usually based on measurement of capillary 3-β-hydroxybutyrate (3-HB) with a hand held ketone sensor. This study was conducted to determine if measurement of capillary 3-HB could be useful for the diagnosis and monitoring of canine DKA. Fifteen dogs with diabetic ketosis and 10 with DKA were evaluated. Paired measurements of 3-HB of capillary and venous blood samples were analysed by the electrochemical sensor and reference method. Use of capillary 3-HB measurement during DKA management was then evaluated through simultaneous measurements of capillary 3-HB, urinary AcAc and venous blood gas analysis. Good agreement between capillary and venous 3-HB measurement was detected by the electrochemical sensor and reference method. Monitoring treatment of DKA revealed a significant correlation between capillary 3-HB and acidosis markers, while no significant correlation was observed between AcAc and acidosis markers. A cut-off value of capillary blood 3-HB > 3.8 mmol/L for diagnosis of DKA resulted in 70% and 92% sensitivity and specificity. The electrochemical sensor accurately measures 3-HB concentration in both capillary and venous blood samples, is accurate in diagnosing canine DKA, and appears to reflect the patient's metabolic status during DKA treatment.

  16. Comparison of Oseltamivir and Oseltamivir Carboxylate Concentrations in Venous Plasma, Venous Blood, and Capillary Blood in Healthy Volunteers

    PubMed Central

    Instiaty, Insti; Lindegardh, Niklas; Jittmala, Podjanee; Hanpithakpong, Warunee; Blessborn, Daniel; Pukrittayakamee, Sasithon; White, Nicholas J.

    2013-01-01

    Oseltamivir and oseltamivir carboxylate concentrations were measured in venous plasma, venous blood, and capillary blood taken simultaneously from 24 healthy volunteers. Median (range) venous-blood-to-plasma ratios were 1.42 (0.920 to 1.97) for oseltamivir and 0.673 (0.564 to 0.814) for oseltamivir carboxylate. Capillary blood/venous plasma ratios were 1.32 (0.737 to 3.16) for oseltamivir and 0.685 (0.502 to 1.34) for oseltamivir carboxylate. Oseltamivir concentrations in venous and capillary blood were similar. Oseltamivir carboxylate showed a time-dependent distribution between venous and capillary blood. PMID:23507284

  17. Lack of utility of arteriojugular venous differences of lactate as a reliable indicator of increased brain anaerobic metabolism in traumatic brain injury.

    PubMed

    Poca, Maria A; Sahuquillo, Juan; Vilalta, Anna; Garnacho, Angel

    2007-04-01

    Ischemic lesions are highly prevalent in patients with traumatic brain injuries (TBIs) and are the single most important cause of secondary brain damage. The prevention and early treatment of these lesions is the primary aim in the modem treatment of these patients. One of the most widely used monitoring techniques at the bedside is quantification of brain extracellular level of lactate by using arteriojugular venous differences of lactate (AVDL). The purpose of this study was to determine the sensitivity, specificity, and predictive value of AVDL as an indicator of increases in brain lactate production in patients with TBIs. Arteriojugular venous differences of lactate were calculated every 6 hours using samples obtained though a catheter placed in the jugular bulb in 45 patients with diffuse head injuries (57.8%) or evacuated brain lesions (42.2%). Cerebral lactate concentration obtained with a 20-kD microdialysis catheter implanted in undamaged tissue was used as the de facto gold standard. Six hundred seventy-three AVDL determinations and cerebral microdialysis samples were obtained simultaneously; 543 microdialysis samples (81%) showed lactate values greater than 2 mmol/L, but only 21 AVDL determinations (3.1%) showed an increase in brain lactate. No correlation was found between AVDL and cerebral lactate concentration (p = 0.014, p = 0.719). Arteriojugular venous differences of lactate had a sensitivity and specificity of 3.3 and 97.7%, respectively, with a false-negative rate of 96.7% and a false-positive rate of 2.3%. Arteriojugular venous differences of lactate do not reliably reflect increased cerebral lactate production and consequently are not reliable in ruling out brain ischemia in patients with TBIs. The clinical use of this monitoring method in neurocritical care should be reconsidered.

  18. Precision of a dry-chemistry method of lipid screening.

    PubMed

    Bowden, Rodney G; Kingery, Paul M; Long, Lindsey

    2006-06-01

    The purpose of this study was to compare total capillary cholesterol values acquired using the Reflotron with a venous sample taken simultaneously, to determine if the Reflotron meets the guidelines of the National Cholesterol Education Program (NCEP) for accuracy. An announcement and a registration form for a cholesterol screening programme were distributed with employee pay slips at a large southern university. Approximately 15 employees were scheduled for each screening date, with walk-ins allowed at the health assessment site as space allowed. Capillary and venous samples were collected from screening participants (n=285). Approximately 20 ml of blood was collected from each participant, after fasting for 12 h, using standardized venepuncture techniques in the antecubital vein in the bend of the elbow. In order to overcome technician error, two drops of blood (30 microl) were collected immediately from the previously drawn venous sample by drawing blood into the capillary tube from the opening in the top of the venous tube before centrifuging the venous sample, rather than 'sticking' the finger. A Kolmogorov-Smirnov (KS) test of normality was calculated for total capillary cholesterol (KS=1.27, P=0.79) and total venous cholesterol (KS=0.99, P=0.28), which revealed insufficient evidence that the distributions were not normal. Participants' total capillary cholesterol values averaged 213.27 mg/dl [standard deviation (SD)=44.66 mg/dl)] when analysed on the Reflotron, and slightly higher (228.86 mg/dl, SD=40.50 mg/dl) for venepuncture. A paired t-test for variance between groups revealed significant differences in total capillary and total venous cholesterol values (t=-41.93, P<0.0001). A mean centered coefficient of variation was performed, revealing a 3.3% error rate, i.e. greater than the 3% allowable by the NCEP III guidelines. The mean percent bias was -7.28% (SD=3.10%) and the absolute mean percent bias was 7.46% (SD=2.64%). The percentage of participants with total cholesterol misclassified was 16.85%. Concomitantly, Spearman correlation coefficients were high (r2=0.94, P=0.01). Although the Reflotron met most of the NCEP III guidelines for accuracy, the portable analyser provided clinically relevant underestimations of total cholesterol values, especially for the lower and upper values. Consequently, lipid values obtained using the Reflotron may be useful for screening, but the Reflotron should not be used as a diagnostic and management tool.

  19. Comparison of oxidative/antioxidative status of penile corpus cavernosum blood and peripheral venous blood.

    PubMed

    Yeni, E; Gulum, M; Selek, S; Erel, O; Unal, D; Verit, A; Savas, M

    2005-01-01

    The aim of the study is to determine and to compare the oxidative and antioxidative status of penile corpus cavernosum and peripheral venous blood. A total of 28 adult healthy males were included in the study. Whole blood was simultaneously withdrawn from penile corpus cavernosum and the cubital vein and their plasma separated. Total antioxidant capacity (TAC), vitamin C, total protein, albumin, uric acid, bilirubin and total peroxide (TP) levels of both plasma samples were measured and compared. While TAC, total protein, albumin, bilirubin and uric acid levels were higher, vitamin C levels were lower in cavernosal blood than that of peripheral blood. On the other hand, TP level was found to be higher in penile blood samples than that of peripheral blood. We thought that the normal erectile process of the penile cavernosal body leads to increased production of oxidants as in the mechanism of ischaemia-reperfusion; however, the increase of TAC can prevent development of oxidative injury.

  20. Agreement between arterial and venous lactate in emergency department patients: a prospective study of 157 consecutive patients.

    PubMed

    Paquet, Anne-Laure; Valli, Vanina; Philippon, Anne-Laure; Devilliers, Catherine; Bloom, Ben; Hausfater, Pierre; Riou, Bruno; Freund, Yonathan

    2018-04-01

    In the emergency department (ED), lactate is routinely used for risk stratification. Whether venous or arterial lactate measured on blood gas is interchangeable is not known. We hypothesized that venous lactate can be used instead of arterial lactate for the evaluation of acute patients in the ED. This was a prospective single-center study. All patients requiring a lactate measurement were enrolled and we simultaneously drew arterial and venous blood. We followed up all patients to hospital discharge. Our primary aim was to evaluate agreements between the two measurements using Bland and Altman plots with the report of bias (mean difference) and limits of agreements. We also aimed to determine the rate of misclassification (defined as one measurement<1.8 mmol/l and the other>2.2). Our secondary aim was to evaluate their respective prognostic value to predict in-hospital death or admission in the ICU longer than 72 h. The mean age of the 132 analyzed patients was 62 years (SD: 18 years), and 59% were men. The mean difference (bias) between arterial and venous lactate was -0.6 mmol/l (limits of agreement: -1.7 to 0.6 mmol/l). The rate of misclassification was 8% (95% confidence interval: 3-2%). Both methods present similar performances for the prediction of poor outcomes, with an area under the receiving operator characteristic curves of 0.67 for both. Results were similar when focused only on septic patients. Venous and arterial lactates do not agree well, and there is a high misclassification rate. Venous lactate does not appear to be interchangeable with arterial sampling.

  1. The use of the venous stripper for graft removal in arterial reoperations.

    PubMed

    Shifrin, E G; Eid, A; Anner, H; Witz, M

    1987-10-01

    A simple technique for removal of synthetic grafts using a standard venous stripper inside the graft is described. The method permits the simultaneous placement of a drainage tube in the canal after graft removal in cases where the graft is infected.

  2. Adrenal vein sampling in primary aldosteronism: concordance of simultaneous vs sequential sampling.

    PubMed

    Almarzooqi, Mohamed-Karji; Chagnon, Miguel; Soulez, Gilles; Giroux, Marie-France; Gilbert, Patrick; Oliva, Vincent L; Perreault, Pierre; Bouchard, Louis; Bourdeau, Isabelle; Lacroix, André; Therasse, Eric

    2017-02-01

    Many investigators believe that basal adrenal venous sampling (AVS) should be done simultaneously, whereas others opt for sequential AVS for simplicity and reduced cost. This study aimed to evaluate the concordance of sequential and simultaneous AVS methods. Between 1989 and 2015, bilateral simultaneous sets of basal AVS were obtained twice within 5 min, in 188 consecutive patients (59 women and 129 men; mean age: 53.4 years). Selectivity was defined by adrenal-to-peripheral cortisol ratio ≥2, and lateralization was defined as an adrenal aldosterone-to-cortisol ratio ≥2, the contralateral side. Sequential AVS was simulated using right sampling at -5 min (t = -5) and left sampling at 0 min (t = 0). There was no significant difference in mean selectivity ratio (P = 0.12 and P = 0.42 for the right and left sides respectively) and in mean lateralization ratio (P = 0.93) between t = -5 and t = 0. Kappa for selectivity between 2 simultaneous AVS was 0.71 (95% CI: 0.60-0.82), whereas it was 0.84 (95% CI: 0.76-0.92) and 0.85 (95% CI: 0.77-0.93) between sequential and simultaneous AVS at respectively -5 min and at 0 min. Kappa for lateralization between 2 simultaneous AVS was 0.84 (95% CI: 0.75-0.93), whereas it was 0.86 (95% CI: 0.78-0.94) and 0.80 (95% CI: 0.71-0.90) between sequential AVS and simultaneous AVS at respectively -5 min at 0 min. Concordance between simultaneous and sequential AVS was not different than that between 2 repeated simultaneous AVS in the same patient. Therefore, a better diagnostic performance is not a good argument to select the AVS method. © 2017 European Society of Endocrinology.

  3. VENOUS SAMPLING FOR CUSHING DISEASE: COMPARISON OF INTERNAL JUGULAR VEIN AND INFERIOR PETROSAL SINUS SAMPLING.

    PubMed

    Radvany, Martin G; Quinones-Hinojosa, Alfredo; Gallia, Gary L; Wand, Gary S; Salvatori, Roberto

    2016-09-01

    Because magnetic resonance imaging (MRI) fails to detect many adrenocorticotropic hormone (ACTH)-secreting pituitary adenomas, inferior petrosal sinus sampling (IPSS) is considered the gold standard to differentiate Cushing disease (CD) from ectopic ACTH secretion syndrome (EAS). Some authors have suggested internal jugular vein sampling (IJVS) as an alternative to IPSS. We simultaneously compared IJVS to IPSS in 30 consecutive patients referred for ACTH-dependent Cushing syndrome and equivocal MRI exams. Five sites were simultaneously sampled in each patient (right and left IPS, right and left IJV, and femoral vein) before and after the administration of corticotrophin-releasing hormone or desmopressin. The test was considered consistent with CD when the IPS to peripheral ratio was >2 at baseline or >3 after stimulus and the IJV to peripheral ratio was >1.7 at baseline or >2 after stimulus. In 27 of 30 patients, IPSS results were consistent with a central source of ACTH. Two of the other 3 patients had EAS (one lung carcinoid and one occult), and 1 patient had pathology-proven CD. The sensitivity of IPSS was 96.4%. Only 64.2% of these patients had results meeting criteria for a central source of ACTH by IJVS criteria. Twenty patients with centralizing IPPS have undergone pituitary surgery. Of these, the central origin of excessive ACTH was confirmed with certainty in 16 patients. Among these 16 patients, the IPSS sensitivity was 93.8%, whereas 5 patients had false-negative IJVS (68.7% sensitivity). These results do not support the routine use of IJVS in establishing if the pituitary is the source of excessive ACTH. ACTH = adrenocorticotropic hormone CD = Cushing disease CRH = corticotrophin-releasing hormone CS = Cushing syndrome DDAVP = desmopressin EAS = ectopic ACTH secretion IJVS = internal jugular vein sampling IPSS = inferior petrosal sinus sampling JVS = jugular venous sampling MRI = magnetic resonance imaging.

  4. Comparison of NIRS, laser Doppler flowmetry, photoplethysmography, and pulse oximetry during vascular occlusion challenges.

    PubMed

    Abay, T Y; Kyriacou, P A

    2016-04-01

    Monitoring changes in blood volume, blood flow, and oxygenation in tissues is of vital importance in fields such as reconstructive surgery and trauma medicine. Near infrared spectroscopy (NIRS), laser Doppler (LDF) flowmetry, photoplethysmography (PPG), and pulse oximetry (PO) contribute to such fields due to their safe and noninvasive nature. However, the techniques have been rarely investigated simultaneously or altogether. The aim of this study was to investigate all the techniques simultaneously on healthy subjects during vascular occlusion challenges. Sensors were attached on the forearm (NIRS and LDF) and fingers (PPG and PO) of 19 healthy volunteers. Different degrees of vascular occlusion were induced by inflating a pressure cuff on the upper arm. The responses of tissue oxygenation index (NIRS), tissue haemoglobin index (NIRS), flux (LDF), perfusion index (PPG), and arterial oxygen saturation (PO) have been recorded and analyzed. Moreover, the optical densities were calculated from slow varying dc PPG, in order to distinguish changes in venous blood volumes. The indexes showed significant changes (p  <  0.05) in almost all occlusions, either venous or over-systolic occlusions. However, differentiation between venous and arterial occlusion by LDF may be challenging and the perfusion index (PI) may not be adequate to indicate venous occlusions. Optical densities may be an additional tool to detect venous occlusions by PPG.

  5. Correlation Between Pediatric Open Heart Surgery Outcomes and Arterial-mixed Venous Oxygen Saturation Differences.

    PubMed

    Samadi, Mahmood; Malaki, Majid; Ghaffari, Shamsi; Golshan Khalili, Roza

    2012-01-01

    Low Cardiac Output Syndrome (LCOS) contributes to postoperative morbidity and mortality. This article tries to find a predictive factor to interpret outcome after cardiac operation. In a cross-sectional study, 100 children with congenital heart disease undergoing cardiovascular surgery with cardiopulmonary bypass (CPB) without significant left-to-right shunt were selected. Arterial and central venous oxygen saturation values were measured via blood samples simultaneously obtained in 6-hr intervals for a total of 24-hr during postoperative period at hours 0, 6, 12, 18, and 24. Postoperative ventilation support (intubation period) and cardiovascular support were also obtained from the hospital records. Statistical analysis was later performed comparing the arterial-mixed venous oxygen saturation differences and durations of required ventilatory and cardiovascular support, both for the complicated and non-complicated patient groups. The data was processed with correlation Pearson and Mann-Whitney U tests in SPSS 15 software, P less than 0.05 was significant. Mortality following cardiac operation is 6% and complications may happen in 45% of the cases. The highest Arterial-mixed venous oxygen saturation difference occurred immediately post operation (up to 57%). These measures were high up to 18 hours in complicated and non-complicated groups (36% vs. 31% ; P< 0.05). This factor cannot predict prolongation of intubation period in patients (P > 0.05). Arterial-mixed venous oxygen saturation difference may be high as much as 57% or as low as 23%.These different measures, being higher up to 18 hours in complicated to non-complicated groups after 18 hours, can be related to tissue ischemia during surgery and cannot be discriminative.

  6. [Clinical value of ammonia determination in venous blood in chronic cor pulmonale].

    PubMed

    Szulc, E J; Sworzyńska, I

    1978-01-01

    The authors have examined 43 workers of the Warszawa works: 20 healthy persons and 23 with chronic pulmocardiac syndrome. An increased ammonia level in venous blood, above 48 gamma %, was found in those with chronic pulmocardiac syndrome with simultaneous circulatory insufficiency. Ammonia level in the blood of those with chronic pulmocardiac syndrome but without circulatory insufficiency was normal. These studies indicate that the increase of ammonia concentration in venous blood in chronic pulmocardiac syndrome results from disturbance in hepatic cell function, intensified during circulatory insufficiency.

  7. Comparison of arterial and venous blood gases and the effects of analysis delay and air contamination on arterial samples in patients with chronic obstructive pulmonary disease and healthy controls.

    PubMed

    O'Connor, T M; Barry, P J; Jahangir, A; Finn, C; Buckley, B M; El-Gammal, A

    2011-01-01

    Arterial blood gases (ABGs) are often sampled incorrectly, leading to a 'mixed' or venous sample. Delays in analysis and air contamination are common. We measured the effects of these errors in patients with chronic obstructive pulmonary disease (COPD) exacerbations and controls. Arterial and venous samples were analyzed from 30 patients with COPD exacerbation and 30 controls. Venous samples were analysed immediately and arterial samples separated into non-air-contaminated and air-contaminated specimens and analysed at 0, 30, 60, 90 and 180 min. Mean venous pH was 7.371 and arterial pH was 7.407 (p < 0.0001). There was a correlation between venous and arterial pH (r = 0.5347, p < 0.0001). The regression equation to predict arterial pH was: arterial pH = 4.2289 + 0.43113 · venous pH. There were no clinically significant differences in arterial PO₂ associated with analysis delay. A statistically significant decline in pH was detected at 30 min in patients with COPD exacerbation (p = 0.0042) and 90 min in controls (p < 0.0001). A clinically significant decline in pH emerged at 73 min in patients with COPD exacerbation and 87 min in controls. Air contamination was associated with a clinically significant increase in PO₂ in all samples, including those that were immediately analyzed. Arterial and venous pH differ significantly. Venous pH cannot accurately replace arterial pH. Temporal delays in ABG analysis result in a significant decline in measured pH. ABGs should be analysed within 30 min. Air contamination leads to an immediate increase in measured PO₂, indicating that air-contaminated ABGs should be discarded. Copyright © 2010 S. Karger AG, Basel.

  8. Simultaneous estimation of arterial and venous oxygen saturation using a camera

    NASA Astrophysics Data System (ADS)

    van Gastel, Mark; Liang, Hangbing; Stuijk, Sander; de Haan, Gerard

    2018-02-01

    Optical monitoring of arterial blood oxygenation, SpO2, using cameras has recently been shown feasible by measuring the relative amplitudes of the remotely sensed PPG waveforms captured at different wavelengths. SvO2 measures the venous blood oxygenation which together with SpO2 provides an indication of tissue oxygen consumption. In contrast to SpO2 it usually still requires a blood sample from a pulmonary artery catheter. In this work we present a method which suggests simultaneous estimation of SpO2 and SvO2 with a camera. Contrary to earlier work, our method does not require external cuffs leading to better usability and improved comfort. Since the arterial blood varies synchronously with the heart rate, all frequencies outside the heart rate band are typically filtered out for SpO2 measurements. For SvO2 estimation, we include intensity variations in the respiratory frequency range since respiration modulates venous blood due to intrathoracic pressure variations in the chest and abdomen. Consequently, under static conditions, the two dominant components in the PPG signals are respiration and pulse. By measuring the amplitude ratios of these components, it seems possible to monitor both SpO2 and SvO2 continuously. We asked healthy subjects to follow an auditory breathing pattern while recording the face and hand. Results show a difference in estimated SpO2 and SvO2 values in the range 5-30 percent for both anatomical locations, which is normal for healthy people. This continuous, non-contact, method shows promise to alert the clinician to a change in patient condition sooner than SpO2 alone.

  9. Venous filling time using air-plethysmography correlates highly with great saphenous vein reflux time using duplex.

    PubMed

    Lattimer, C R; Azzam, M; Kalodiki, E; Geroulakos, G

    2014-03-01

    Venous filling time (VFT90) is the time taken to reach 90% of the venous volume in the calf. It is recorded by air-plethysmography (APG(®)) and is assumed to measure global venous reflux duration. However, this has never been confirmed by duplex. The aim of the study was to compare VFT on APG to venous reflux time/duration (RT) measured simultaneously with duplex on the same patients. Twenty-six consecutive patients, M:F = 16:10, age (25-78), C1 = 1, C2 = 4, C3 = 8, C4a = 6, C4b = 4, C5 = 2, C6 = 1, underwent simultaneous APG with duplex. The venous filling index (VFI, mL/second), VFT90 (seconds), great saphenous vein (GSV) RT on duplex, averaged thigh GSV diameter and thigh length (length) between the APG sensor air-cuff and duplex transducer were recorded. The VFT100 was calculated by VFT90/0.9. The additional time taken to fill the thigh was achieved using the VFI, length and deep vein diameter (d), to determine the corrected reflux duration: CRD = VFT100 + (length × πd(2)/4 (1/VFI)). Twenty-five patients are presented. One patient with very mild reflux (VFT90 = 55.9 seconds) had an indeterminate endpoint on duplex and was excluded. The median (range) VFI and GSV diameter was 4.9(1.3-15.5) mL/second and 7(4-17) mm, respectively. The VFT90 and VFT100 both correlated with RT on duplex (Spearman, P < 0.0005) at: r = 0.933, r(2) linear = 0.72 and r = 0.933, r(2) linear = 0.68, respectively. The median (interquartile range) filling time with VFT90 was less than the duplex RT at 24 (16.9) versus 28 (20) seconds respectively, P < 0.0005 (Wilcoxon). The median percentage underestimation improved from 24% to 16% and then 4% using the VFT90, VFT100 and CRD, respectively. This is the first study to compare APG parameters with duplex by performing simultaneous measurements. There was an excellent correlation between the VFT90 versus duplex RT, thereby comparing reverse flow in a single superficial vein against the legs overall venous haemodynamic status. These tests can both be used in the quantification of reflux.

  10. Quantification of multiple elements in dried blood spot samples.

    PubMed

    Pedersen, Lise; Andersen-Ranberg, Karen; Hollergaard, Mads; Nybo, Mads

    2017-08-01

    Dried blood spots (DBS) is a unique matrix that offers advantages compared to conventional blood collection making it increasingly popular in large population studies. We here describe development and validation of a method to determine multiple elements in DBS. Elements were extracted from punches and analyzed using inductively coupled plasma-mass spectrometry (ICP-MS). The method was evaluated with quality controls with defined element concentration and blood spiked with elements to assess accuracy and imprecision. DBS element concentrations were compared with concentrations in venous blood. Samples with different hematocrit were spotted onto filter paper to assess hematocrit effect. The established method was precise and accurate for measurement of most elements in DBS. There was a significant but relatively weak correlation between measurement of the elements Mg, K, Fe, Cu, Zn, As and Se in DBS and venous whole blood. Hematocrit influenced the DBS element measurement, especially for K, Fe and Zn. Trace elements can be measured with high accuracy and low imprecision in DBS, but contribution of signal from the filter paper influences measurement of some elements present at low concentrations. Simultaneous measurement of K and Fe in DBS extracts may be used to estimate sample hematocrit. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  11. Venous thromboembolism and arterial complications.

    PubMed

    Prandoni, Paolo; Piovella, Chiara; Pesavento, Raffaele

    2012-04-01

    An increasing body of evidence suggests the likelihood of a link between venous and arterial thrombosis. The two vascular complications share several risk factors, such as age, obesity, smoking, diabetes mellitus, blood hypertension, hypertriglyceridemia, and metabolic syndrome. Moreover, there are many examples of conditions accounting for both venous and arterial thrombosis, such as the antiphospholipid antibody syndrome, hyperhomocysteinemia, malignancies, infections, and the use of hormonal treatment. Finally, several recent studies have consistently shown that patients with venous thromboembolism are at a higher risk of arterial thrombotic complications than matched control individuals. We, therefore, speculate the two vascular complications are simultaneously triggered by biological stimuli responsible for activating coagulation and inflammatory pathways in both the arterial and the venous system. Future studies are needed to clarify the nature of this association, to assess its extent, and to evaluate its implications for clinical practice. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  12. Multidetector CT angiography in living donor renal transplantation: accuracy and discrepancies in right venous anatomy.

    PubMed

    Kulkarni, S; Emre, S; Arvelakis, A; Asch, W; Bia, M; Formica, R; Israel, G

    2011-01-01

    Multidetector computed tomography (MDCT) angiography is a reliable technique for assessing pre-operative renal anatomy in living kidney donors. The method has largely evolved into protocols that eliminate dedicated venous phase and instead utilize a combined arterial/venous phase to delineate arterial and venous anatomy simultaneously. Despite adoption of this protocol, there has been no study to assess its accuracy. To assess whether or not MDCT angiography compares favorably to intra-operative findings, 102 donors underwent MDCT angiography without a dedicated venous phase with surgical interpretation of renal anatomy. Anatomical variants included multiple arteries (12%), multiple veins (7%), early arterial bifurcation (13%), late venous confluence (5%), circumaortic renal veins (5%), retroaortic vein (1%), and ureteral duplication (2%). The sensitivity and specificity of multiple arterial anomalies were 100% and 97%, respectively. The sensitivity and specificity of multiple venous anomalies were 92% and 98%, respectively. The most common discrepancy was noted exclusively in the interpretation of right venous anatomy as it pertained to the renal vein/vena cava confluence (3%). MDCT angiography using a combined arterial/venous contrast-enhanced phase provides suitable depiction of renal donor anatomy. Careful consideration should be given when planning a right donor nephrectomy whether the radiographic interpretation is suggestive of a late confluence. © 2010 John Wiley & Sons A/S.

  13. A content validated questionnaire for assessment of self reported venous blood sampling practices

    PubMed Central

    2012-01-01

    Background Venous blood sampling is a common procedure in health care. It is strictly regulated by national and international guidelines. Deviations from guidelines due to human mistakes can cause patient harm. Validated questionnaires for health care personnel can be used to assess preventable "near misses"--i.e. potential errors and nonconformities during venous blood sampling practices that could transform into adverse events. However, no validated questionnaire that assesses nonconformities in venous blood sampling has previously been presented. The aim was to test a recently developed questionnaire in self reported venous blood sampling practices for validity and reliability. Findings We developed a questionnaire to assess deviations from best practices during venous blood sampling. The questionnaire contained questions about patient identification, test request management, test tube labeling, test tube handling, information search procedures and frequencies of error reporting. For content validity, the questionnaire was confirmed by experts on questionnaires and venous blood sampling. For reliability, test-retest statistics were used on the questionnaire answered twice. The final venous blood sampling questionnaire included 19 questions out of which 9 had in total 34 underlying items. It was found to have content validity. The test-retest analysis demonstrated that the items were generally stable. In total, 82% of the items fulfilled the reliability acceptance criteria. Conclusions The questionnaire could be used for assessment of "near miss" practices that could jeopardize patient safety and gives several benefits instead of assessing rare adverse events only. The higher frequencies of "near miss" practices allows for quantitative analysis of the effect of corrective interventions and to benchmark preanalytical quality not only at the laboratory/hospital level but also at the health care unit/hospital ward. PMID:22260505

  14. A content validated questionnaire for assessment of self reported venous blood sampling practices.

    PubMed

    Bölenius, Karin; Brulin, Christine; Grankvist, Kjell; Lindkvist, Marie; Söderberg, Johan

    2012-01-19

    Venous blood sampling is a common procedure in health care. It is strictly regulated by national and international guidelines. Deviations from guidelines due to human mistakes can cause patient harm. Validated questionnaires for health care personnel can be used to assess preventable "near misses"--i.e. potential errors and nonconformities during venous blood sampling practices that could transform into adverse events. However, no validated questionnaire that assesses nonconformities in venous blood sampling has previously been presented. The aim was to test a recently developed questionnaire in self reported venous blood sampling practices for validity and reliability. We developed a questionnaire to assess deviations from best practices during venous blood sampling. The questionnaire contained questions about patient identification, test request management, test tube labeling, test tube handling, information search procedures and frequencies of error reporting. For content validity, the questionnaire was confirmed by experts on questionnaires and venous blood sampling. For reliability, test-retest statistics were used on the questionnaire answered twice. The final venous blood sampling questionnaire included 19 questions out of which 9 had in total 34 underlying items. It was found to have content validity. The test-retest analysis demonstrated that the items were generally stable. In total, 82% of the items fulfilled the reliability acceptance criteria. The questionnaire could be used for assessment of "near miss" practices that could jeopardize patient safety and gives several benefits instead of assessing rare adverse events only. The higher frequencies of "near miss" practices allows for quantitative analysis of the effect of corrective interventions and to benchmark preanalytical quality not only at the laboratory/hospital level but also at the health care unit/hospital ward.

  15. Effects of Changes in Arterial Carbon Dioxide and Oxygen Partial Pressures on Cerebral Oximeter Performance.

    PubMed

    Schober, Andrew; Feiner, John R; Bickler, Philip E; Rollins, Mark D

    2018-01-01

    Cerebral oximetry (cerebral oxygen saturation; ScO2) is used to noninvasively monitor cerebral oxygenation. ScO2 readings are based on the fraction of reduced and oxidized hemoglobin as an indirect estimate of brain tissue oxygenation and assume a static ratio of arterial to venous intracranial blood. Conditions that alter cerebral blood flow, such as acute changes in PaCO2, may decrease accuracy. We assessed the performance of two commercial cerebral oximeters across a range of oxygen concentrations during normocapnia and hypocapnia. Casmed FORE-SIGHT Elite (CAS Medical Systems, Inc., USA) and Covidien INVOS 5100C (Covidien, USA) oximeter sensors were placed on 12 healthy volunteers. The fractional inspired oxygen tension was varied to achieve seven steady-state levels including hypoxic and hyperoxic PaO2 values. ScO2 and simultaneous arterial and jugular venous blood gas measurements were obtained with both normocapnia and hypocapnia. Oximeter bias was calculated as the difference between the ScO2 and reference saturation using manufacturer-specified weighting ratios from the arterial and venous samples. FORE-SIGHT Elite bias was greater during hypocapnia as compared with normocapnia (4 ± 9% vs. 0 ± 6%; P < 0.001). The INVOS 5100C bias was also lower during normocapnia (5 ± 15% vs. 3 ± 12%; P = 0.01). Hypocapnia resulted in a significant decrease in mixed venous oxygen saturation and mixed venous oxygen tension, as well as increased oxygen extraction across fractional inspired oxygen tension levels (P < 0.0001). Bias increased significantly with increasing oxygen extraction (P < 0.0001). Changes in PaCO2 affect cerebral oximeter accuracy, and increased bias occurs with hypocapnia. Decreased accuracy may represent an incorrect assumption of a static arterial-venous blood fraction. Understanding cerebral oximetry limitations is especially important in patients at risk for hypoxia-induced brain injury, where PaCO2 may be purposefully altered.

  16. Usefulness of venous oxygen saturation in the jugular bulb for the diagnosis of brain death: report of 118 patients.

    PubMed

    Díaz-Regañón, Genaro; Miñambres, Eduardo; Holanda, Marisol; González-Herrera, Segundo; López-Espadas, Francisco; Garrido-Díaz, Carlos

    2002-12-01

    To assess the usefulness of venous oxygen saturation in the jugular bulb (SjO(2)) as a complementary test for the diagnosis of brain death. Prospective observational study. Polytrauma intensive care unit (ICU) of an acute-care teaching hospital in Santander, Spain. We studied 118 (44%) out of 270 patients with severe head injury and intracranial hemorrhage meeting criteria of brain death (lack of cardiac response to atropine, unresponsive apnea, and iso-electric EEG in the absence of shock, hypotension and treatment with muscle relaxants and/or central nervous system (CNS) depressant drugs). At the moment at which clinical diagnosis of brain death was made and an iso-electric EEG was obtained, simultaneous oxygen saturation in central venous blood (right atrium) (SvO(2)) and jugular venous bulb (SjO(2)) samples was measured. The ratio between SvO(2) and SjO(2), expressed as CvjO(2) (the so-called central venous-jugular bulb oxygen saturation rate; CvjO(2) = SvO(2)/SjO(2)) was calculated. CvjO(2) less than 1 was obtained in 114 patients [mean (SD): 0.89 (0.02)], whereas CvjO(2) greater than 1 was obtained in only 4 (3.38%). In the group of 152 survivors, a single patient was discharged from the ICU in a vegetative state in which CvjO(2) was below 1. CvjO(2)as a complementary test for the diagnosis of brain death showed 96.6% sensitivity, 99.3% specificity, and 99.1% and 97.4% positive and negative predictive values, respectively. Central venous-jugular bulb oxygen saturation rate below 1 together with accepted clinical criteria (unresponsive coma with brainstem areflexia) provides non-invasive assessment of cerebral circulatory arrest that can help to suspect brain death.

  17. Arterial versus venous lactate: a measure of sepsis in children.

    PubMed

    Samaraweera, Sahan Asela; Gibbons, Berwyck; Gour, Anami; Sedgwick, Philip

    2017-08-01

    This study assessed the agreement between arterial and venous blood lactate and pH levels in children with sepsis. This retrospective, three-year study involved 60 PICU patients, with data collected from electronic or paper patient records. The inclusion criteria comprised of children (≤17 years old) with sepsis and those who had a venous blood gas taken first with an arterial blood gas taken after within one hour. The lactate and pH values measured through each method were analysed. There is close agreement between venous and arterial lactate up to 2 mmol/L. As this value increases, this agreement becomes poor. The limits of agreement (LOA) are too large (±1.90 mmol/L) to allow venous and arterial lactate to be used interchangeably. The mean difference and LOA between both methods would be much smaller if derived using lactate values under 2.0 mmol/L. There is close agreement between arterial and venous pH (MD = -0.056, LOA ± 0.121). However, due to extreme variations in pH readings during sepsis, pH alone is an inadequate marker. A venous lactate ≤2 mmol/L can be used as a surrogate for arterial lactate during early management of sepsis in children. However, if the value exceeds 2 mmol/L, an arterial sample must confirm the venous result. What is known: • In children with septic shock, a blood gas is an important test to show the presence of acidosis and high lactic acid. Hyperlactataemia on admission is an early predictor of outcome and is associated with a greater mortality risk. • An arterial sample is the standard for lactate measurement, however getting a sample may be challenging in the emergency department or a general paediatric ward. Venous samples are quicker and easier to obtain. Adult studies generally advise caution in replacing venous lactate values for the arterial standard, whilst paediatric studies are limited in this area. What is new: • This is the first study assessing the agreement between arterial and peripheral venous lactate in children with sepsis, with a significant sample of patients. • This study shows that a venous sample with a lactate of ≤ 2 mmol/L can be used as a surrogate measurement for arterial lactate during early management of sepsis in children. However, if the venous lactate is above 2 mmol/L, an arterial sample must be taken to confirm the result.

  18. Capillary and venous samples of total creatine kinase are similar after eccentric exercise.

    PubMed

    Knoblauch, Mark A; O'Connor, Daniel P; Clarke, Mark S F

    2010-12-01

    Circulating creatine kinase (CK) levels are often monitored as an indirect biomarker of muscle damage after resistive exercise. The purpose of the present investigation was to evaluate whether capillary whole-blood sampling, a simpler and less invasive method for obtaining a venous blood sample, would allow for a reliable measurement of total CK compared to venipuncture. Fifteen untrained subjects performed 50 maximal eccentric elbow extensions to induce muscle damage of the biceps brachii. Capillary (fingerstick) and venous whole-blood samples were collected contemporaneously at baseline and again at 24, 48, 72, and 96 hours post-exercise. Using a commercial CK analysis kit with a protocol modification to account for a reduced sample size, total CK activity of the capillary and venous samples was analyzed concurrently via spectrophotometry. Results indicated a 0.997 correlation between sampling sites for total CK, with disagreement between the venous and capillary samples estimated at <12% across the range of CK values. These findings indicate capillary sampling for total CK activity provides a valid alternative to venipuncture and should be considered by researchers, clinicians, and strength and conditioning specialists as an alternate sampling technique when indirectly evaluating muscle damage after exercise.

  19. Use of Dried Capillary Blood Sampling for Islet Autoantibody Screening in Relatives: A Feasibility Study.

    PubMed

    Bingley, Polly J; Rafkin, Lisa E; Matheson, Della; Steck, Andrea K; Yu, Liping; Henderson, Courtney; Beam, Craig A; Boulware, David C

    2015-12-01

    Islet autoantibody testing provides the basis for assessment of risk of progression to type 1 diabetes. We set out to determine the feasibility and acceptability of dried capillary blood spot-based screening to identify islet autoantibody-positive relatives potentially eligible for inclusion in prevention trials. Dried blood spot (DBS) and venous samples were collected from 229 relatives participating in the TrialNet Pathway to Prevention Study. Both samples were tested for glutamic acid decarboxylase, islet antigen 2, and zinc transporter 8 autoantibodies, and venous samples were additionally tested for insulin autoantibodies and islet cell antibodies. We defined multiple autoantibody positive as two or more autoantibodies in venous serum and DBS screen positive if one or more autoantibodies were detected. Participant questionnaires compared the sample collection methods. Of 44 relatives who were multiple autoantibody positive in venous samples, 42 (95.5%) were DBS screen positive, and DBS accurately detected 145 of 147 autoantibody-negative relatives (98.6%). Capillary blood sampling was perceived as more painful than venous blood draw, but 60% of participants would prefer initial screening using home fingerstick with clinic visits only required if autoantibodies were found. Capillary blood sampling could facilitate screening for type 1 diabetes prevention studies.

  20. Involvement of pterygoid venous plexus in patulous eustachian tube symptoms.

    PubMed

    Oshima, Takeshi; Ogura, Masaki; Kikuchi, Toshiaki; Hori, Yoko; Mugikura, Shunji; Higano, Shuichi; Takahashi, Shoki; Kawase, Tetsuaki; Kobayashi, Toshimitsu

    2007-07-01

    The pterygoid venous plexus (PVP) is an important factor in the mechanism of eustachian tube (ET) closure under conditions that can cause increased venous pressure in the head, such as during neck compression and postural change from the sitting/standing to the recumbent position. The symptoms of patulous ET are usually improved by neck compression or postural change (from sitting/standing to recumbent position). Venous congestion around the ET and/or gravitational change may be involved in the changing degree of symptoms, but its mechanism is not understood. This study investigated whether the PVP is involved. The dimensions of soft tissues surrounding ET were measured on magnetic resonance images before and after neck compression. The lateral pterygoid muscle became enlarged after neck compression. Simultaneously, the volume of venous plexus observed between the medial pterygoid muscle and tensor veli palatini muscle was increased. Such enlargement was probably due to blood pooling in the PVP, resulting in protrusion of the ET anterior wall to the luminal side, and decreased ET patency.

  1. Blood sample collection and patient identification demand improvement: a questionnaire study of preanalytical practices in hospital wards and laboratories.

    PubMed

    Wallin, Olof; Söderberg, Johan; Van Guelpen, Bethany; Stenlund, Hans; Grankvist, Kjell; Brulin, Christine

    2010-09-01

    Scand J Caring Sci; 2010; 24; 581-591 
 Blood sample collection and patient identification demand improvement: a questionnaire study of preanalytical practices in hospital wards and laboratories   Most errors in venous blood testing result from human mistakes occurring before the sample reach the laboratory.   To survey venous blood sampling (VBS) practices in hospital wards and to compare practices with hospital laboratories.   Staff in two hospitals (all wards) and two hospital laboratories (314 respondents, response rate 94%), completed a questionnaire addressing issues relevant to the collection of venous blood samples for clinical chemistry testing.   The findings suggest that instructions for patient identification and the collection of venous blood samples were not always followed. For example, 79% of the respondents reported the undesirable practice (UDP) of not always using wristbands for patient identification. Similarly, 87% of the respondents noted the UDP of removing venous stasis after the sampling is finished. Compared with the ward staff, a significantly higher proportion of the laboratory staff reported desirable practices regarding the collection of venous blood samples. Neither education nor the existence of established sampling routines was clearly associated with VBS practices among the ward staff.   The results of this study, the first of its kind, suggest that a clinically important risk of error is associated with VBS in the surveyed wards. Most important is the risk of misidentification of patients. Quality improvement of blood sample collection is clearly needed, particularly in hospital wards. © 2009 The Authors. Journal compilation © 2009 Nordic College of Caring Science.

  2. SFE/SFHTA/AFCE consensus on primary aldosteronism, part 4: Subtype diagnosis.

    PubMed

    Bardet, Stéphane; Chamontin, Bernard; Douillard, Claire; Pagny, Jean-Yves; Hernigou, Anne; Joffre, Francis; Plouin, Pierre-François; Steichen, Olivier

    2016-07-01

    To establish the cause of primary aldosteronism (PA), it is essential to distinguish unilateral from bilateral adrenal aldosterone secretion, as adrenalectomy improves aldosterone secretion and controls hypertension and hypokalemia only in the former. Except in the rare cases of type 1 or 3 familial hyperaldosteronism, which can be diagnosed genetically and are not candidates for surgery, lateralized aldosterone secretion is diagnosed on adrenal CT or MRI and adrenal venous sampling. Postural stimulation tests and (131)I-norcholesterol scintigraphy have poor diagnostic value and (11)C-metomidate PET is not yet available. We recommend that adrenal CT or MRI be performed in all cases of PA. Imaging may exceptionally identify adrenocortical carcinoma, for which the surgical objectives are carcinologic, and otherwise shows either normal or hyperplastic adrenals or unilateral adenoma. Imaging alone carries a risk of false positives in patients over 35 years of age (non-aldosterone-secreting adenoma) and false negatives in all patients (unilateral hyperplasia). We suggest that all candidates for surgery over 35 years of age undergo adrenal venous sampling, simultaneously in both adrenal veins, without ACTH stimulation, to confirm the unilateral form of the hypersecretion. Sampling results should be confirmed on adrenal vein cortisol assay showing a concentration at least double that found in peripheral veins. Aldosterone secretion should be considered lateralized when aldosterone/cortisol ratio on the dominant side is at least 4-fold higher than contralaterally. Published by Elsevier Masson SAS.

  3. Use of Dried Capillary Blood Sampling for Islet Autoantibody Screening in Relatives: A Feasibility Study

    PubMed Central

    Rafkin, Lisa E.; Matheson, Della; Steck, Andrea K.; Yu, Liping; Henderson, Courtney; Beam, Craig A.; Boulware, David C.

    2015-01-01

    Abstract Background: Islet autoantibody testing provides the basis for assessment of risk of progression to type 1 diabetes. We set out to determine the feasibility and acceptability of dried capillary blood spot–based screening to identify islet autoantibody–positive relatives potentially eligible for inclusion in prevention trials. Materials and Methods: Dried blood spot (DBS) and venous samples were collected from 229 relatives participating in the TrialNet Pathway to Prevention Study. Both samples were tested for glutamic acid decarboxylase, islet antigen 2, and zinc transporter 8 autoantibodies, and venous samples were additionally tested for insulin autoantibodies and islet cell antibodies. We defined multiple autoantibody positive as two or more autoantibodies in venous serum and DBS screen positive if one or more autoantibodies were detected. Participant questionnaires compared the sample collection methods. Results: Of 44 relatives who were multiple autoantibody positive in venous samples, 42 (95.5%) were DBS screen positive, and DBS accurately detected 145 of 147 autoantibody-negative relatives (98.6%). Capillary blood sampling was perceived as more painful than venous blood draw, but 60% of participants would prefer initial screening using home fingerstick with clinic visits only required if autoantibodies were found. Conclusions: Capillary blood sampling could facilitate screening for type 1 diabetes prevention studies. PMID:26375197

  4. The Essentials of Parathyroid Hormone Venous Sampling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Taslakian, Bedros, E-mail: btaslakian@gmail.com; Trerotola, Scott O., E-mail: streroto@uphs.upenn.edu; Sacks, Barry, E-mail: bsacks@bidmc.harvard.edu

    Hyperparathyroidism is an excess of parathyroid hormone in the blood due to over-activity of one or more parathyroid gland. Localization of abnormal glands with noninvasive imaging modalities, such as technetium sestamibi scan and cross-sectional imaging, has a high success rate. Parathyroid venous sampling is performed for patients with persistent or recurrent disease after previous parathyroid surgery, when repeat noninvasive imaging studies are negative or discordant. The success of invasive localization studies and results interpretation is dependent on the interventional radiologist’s understanding of the normal and ectopic anatomic locations of parathyroid glands, as well as their blood supply and venous drainage.more » Anatomic and technical considerations for selective parathyroid venous sampling are reviewed.« less

  5. Measurement of T1 of human arterial and venous blood at 7T.

    PubMed

    Rane, Swati D; Gore, John C

    2013-04-01

    Techniques for measuring cerebral perfusion require accurate longitudinal relaxation (T1) of blood, an MRI parameter that is field dependent. T1 of arterial and venous human blood was measured at 7T using three different sources - pathology laboratory, blood bank and in vivo. The T1 of venous blood was measured from sealed samples from a pathology lab and in vivo. Samples from a blood bank were oxygenated and mixed to obtain different physiological concentrations of hematocrit and oxygenation. T1 relaxation times were estimated using a three-point fit to a simple inversion recovery equation. At 37°C, the T1 of blood at arterial pO2 was 2.29±0.1s and 2.07±0.12 at venous pO2. The in vivo T1 of venous blood, in three subjects, was slightly longer at 2.45±0.11s. T1 of arterial and venous blood at 7T was measured and found to be significantly different. The T1 values were longer in vivo than in vitro. While the exact cause for the discrepancy is unknown, the additives in the blood samples, degradation during experiment, oxygenation differences, and the non-stagnant nature of blood in vivo could be potential contributors to the lower values of T1 in the venous samples. Copyright © 2013 Elsevier Inc. All rights reserved.

  6. Accuracy of chest radiography for positioning of the umbilical venous catheter.

    PubMed

    Guimarães, Adriana F M; Souza, Aline A C G de; Bouzada, Maria Cândida F; Meira, Zilda M A

    To evaluate the accuracy of the simultaneous analysis of three radiographic anatomical landmarks - diaphragm, cardiac silhouette, and vertebral bodies - in determining the position of the umbilical venous catheter distal end using echocardiography as a reference standard. This was a cross-sectional, observational study, with the prospective inclusion of data from all neonates born in a public reference hospital, between April 2012 and September 2013, submitted to umbilical venous catheter insertion as part of their medical care. The position of the catheter distal end, determined by the simultaneous analysis of three radiographic anatomical landmarks, was compared with the anatomical position obtained by echocardiography; sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were calculated. Of the 162 newborns assessed by echocardiography, only 44 (27.16%) had the catheter in optimal position, in the thoracic portion of the inferior vena cava or at the junction of the inferior vena cava with the right atrium. The catheters were located in the left atrium and interatrial septum in 54 (33.33%) newborns, in the right atrium in 26 (16.05%), intra-hepatic in 37 (22.84%), and intra-aortic in-one newborn (0.62%). The sensitivity, specificity and accuracy of the radiography to detect the catheter in the target area were 56%, 71%, and 67.28%, respectively. Anteroposterior radiography of the chest alone is not able to safely define the umbilical venous catheter position. Echocardiography allows direct visualization of the catheter tip in relation to vascular structures and, whenever possible, should be considered to identify the location of the umbilical venous catheter. Copyright © 2016 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  7. Clinical Validation of Simultaneous Analysis of Tacrolimus, Cyclosporine A, and Creatinine in Dried Blood Spots in Kidney Transplant Patients.

    PubMed

    Veenhof, Herman; Koster, Remco A; Alffenaar, Jan-Willem C; Berger, Stefan P; Bakker, Stephan J L; Touw, Daan J

    2017-07-01

    Monitoring of creatinine and immunosuppressive drug concentrations, such as tacrolimus (TaC) and cyclosporin A (CsA), is important in the outpatient follow-up of kidney transplant recipients. Monitoring by dried blood spot (DBS) provides patients the opportunity to sample a drop of blood from a fingerprick at home, which can be sent to the laboratory by mail. We performed a clinical validation in which we compared measurements from whole-blood samples obtained by venapuncture with measurements from DBS samples simultaneously obtained by fingerprick. After exclusion of 10 DBS for poor quality, and 2 for other reasons, 199, 104, and 58 samples from a total of 172 patients were available for validation of creatinine, TaC and CsA, respectively. Validation was performed by means of Passing & Bablok regression, and bias was assessed by Bland-Altman analysis. For creatinine, we found y = 0.73x - 1.55 (95% confidence interval [95% CI] slope, 0.71-0.76), giving the conversion formula: (creatinine plasma concentration in μmol/L) = (creatinine concentration in DBS in μmol/L)/0.73, with a nonclinically relevant bias of -2.1 μmol/L (95% CI, -3.7 to -0.5 μmol/L). For TaC, we found y = 1.00x - 0.23 (95% CI slope, 0.91-1.08), with a nonclinically relevant bias of -0.28 μg/L (95% CI, -0.45 to -0.12 μg/L). For CsA, we found y = 0.99x - 1.86 (95% CI slope, 0.91-1.08) and no significant bias. Therefore, for neither TaC nor CsA, a conversion formula is required. DBS sampling for the simultaneous analysis of immunosuppressants and creatinine can replace conventional venous sampling in daily routine.

  8. Do capillary dried blood spot concentrations of gamma-hydroxybutyric acid mirror those in venous blood? A comparative study.

    PubMed

    Sadones, Nele; Archer, John R H; Ingels, Ann-Sofie M E; Dargan, Paul I; Wood, David M; Wood, Michelle; Neels, Hugo; Lambert, Willy E; Stove, Christophe P

    2015-04-01

    Gamma-hydroxybutyric acid (GHB) is a well-known illicit club and date-rape drug. Dried blood spot (DBS) sampling is a promising alternative for classical venous sampling in cases of (suspected) GHB intoxication since it allows rapid sampling, which is of interest for the extensively metabolized GHB. However, there is limited data if -and how- capillary DBS concentrations correlate with venous concentrations. We conducted a comparative study in 50 patients with suspected GHB intoxication, to determine and to correlate GHB concentrations in venous DBS (vDBS) and capillary DBS (cDBS). This is the first study that evaluates in a large cohort the correlation between capillary and venous concentrations of an illicit drug in real-life samples. Of the 50 paired samples, 7 were excluded: the vDBS concentration was below the LLOQ of 2 µg/mL in 3 cases and 4 samples were excluded after visual inspection of the DBS. Bland-Altman analysis revealed a mean % difference of -2.8% between cDBS and vDBS concentrations, with the zero value included in the 95% confidence interval of the mean difference in GHB concentration. A paired sample t-test confirmed this observation (p = 0.17). Also the requirement for incurred sample reproducibility was fulfilled: for more than two-thirds of the samples the concentrations obtained in cDBS and those in vDBS were within 20% of their mean. Since equivalent concentrations were observed in cDBS and vDBS, blood obtained by fingerprick can be considered a valid alternative for venous blood for GHB determination. Copyright © 2015 John Wiley & Sons, Ltd.

  9. Iliac vein stenosis is an underdiagnosed cause of pelvic venous insufficiency.

    PubMed

    Santoshi, Ratnam K N; Lakhanpal, Sanjiv; Satwah, Vinay; Lakhanpal, Gaurav; Malone, Michael; Pappas, Peter J

    2018-03-01

    Reflux in the ovarian veins, with or without an obstructive venous outflow component, is reported to be the primary cause of pelvic venous insufficiency (PVI). The degree to which venous outflow obstruction plays a role in PVI is currently ill-defined. We retrospectively reviewed the charts of 227 women with PVI who presented to the Center for Vascular Medicine from January 2012 to September 2015. Assessments and interventions consisted of an evaluation for other causes of chronic pelvic pain by a gynecologist; preintervention and postintervention visual analog scale (VAS) pain score; complete venous duplex ultrasound examination; and Clinical, Etiology, Anatomy, and Pathophysiology classification. All patients underwent diagnostic venography of their pelvic and left ovarian veins as well as intravascular ultrasound of their iliac veins. Patients were treated in one of six ways: ovarian vein embolization (OVE) alone (chemical ± coils), OVE with staged iliac vein stenting, OVE with simultaneous iliac vein stenting, iliac vein stenting alone, OVE with venoplasty, and venoplasty alone. Of the 227 women treated, the average age and number of pregnancies was 46.4 ± 10.4 years and 3.36 ± 1.99, respectively. Treatment distribution was the following: OVE, n = 39; OVE with staged stenting, n = 94; OVE with simultaneous stenting, n = 33; stenting alone, n = 50; OVE with venoplasty, n = 8; and venoplasty alone, n = 3. Seven patients in the OVE and stenting groups (staged) and one patient in the OVE + venoplasty group required a second embolization of the left ovarian vein. Eighty percent (181/227) of patients demonstrated an iliac stenosis >50% by intravascular ultrasound. Average VAS scores for the entire cohort before and after intervention were 8.45 ± 1.11 and 1.86 ± 1.61 (P ≤ .001). In the staged group, only 9 of 94 patients reported a decrease in the VAS score with OVE alone. VAS score decreased from 8.6 ± 0.89 before OVE to 7.97 ± 2.10 after OVE. After the planned staged stenting, VAS score decreased to 1.33 ± 2.33 (P ≤ .001). Similarly, in the simultaneous group, preintervention scores were 8.63 ± 1.07 and decreased to 2.36 ± 2.67 after OVE + stenting (P ≤ .001). The majority of patients in our series (80%) demonstrated a significant iliac vein stenosis. These observations indicate that the incidence of iliac vein outflow obstruction in PVI is greater than previously reported. In patients with combined ovarian vein reflux and iliac vein outflow obstruction, our data suggest that pelvic venous outflow lesions should be treated first and that ovarian vein reflux should be treated only if symptoms persist. In women with an outflow lesion, ovarian vein reflux, and a large pelvic reservoir, we recommend simultaneous treatment. Copyright © 2017 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  10. Evaluation of the performance of a point-of-care method for total and differential white blood cell count in clozapine users.

    PubMed

    Bui, H N; Bogers, J P A M; Cohen, D; Njo, T; Herruer, M H

    2016-12-01

    We evaluated the performance of the HemoCue WBC DIFF, a point-of-care device for total and differential white cell count, primarily to test its suitability for the mandatory white blood cell monitoring in clozapine use. Leukocyte count and 5-part differentiation was performed by the point-of-care device and by routine laboratory method in venous EDTA-blood samples from 20 clozapine users, 20 neutropenic patients, and 20 healthy volunteers. From the volunteers, also a capillary sample was drawn. Intra-assay reproducibility and drop-to-drop variation were tested. The correlation between both methods in venous samples was r > 0.95 for leukocyte, neutrophil, and lymphocyte counts. The correlation between point-of-care (capillary sample) and routine (venous sample) methods for these cells was 0.772; 0.817 and 0.798, respectively. Only for leukocyte and neutrophil counts, the intra-assay reproducibility was sufficient. The point-of-care device can be used to screen for leukocyte and neutrophil counts. Because of the relatively high measurement uncertainty and poor correlation with venous samples, we recommend to repeat the measurement with a venous sample if cell counts are in the lower reference range. In case of clozapine therapy, neutropenia can probably be excluded if high neutrophil counts are found and patients can continue their therapy. © 2016 John Wiley & Sons Ltd.

  11. The measurement of carboxyhemoglobin and methemoglobin using a non-invasive pulse CO-oximeter.

    PubMed

    Zaouter, Cédrick; Zavorsky, Gerald S

    2012-07-01

    The pulse CO-oximeter (Rad-57 Masimo Corporation, Irvine, CA) allows non-invasive and instantaneous measurement of carboxyhemoglobin (COHb) and methemoglobin (MetHb) percentage level using a finger probe. However, the accuracy and reliability of the Rad-57 against the gold standard of venous or arterial blood samples have not been clearly established. Thus, the objective of this trial is to evaluate the accuracy and precision of the Rad-57 pulse CO-oximeter by comparing it with venous sampling on the same subjects. Nine healthy subjects were subjected to carbon monoxide such that it raised the COHb to 10-14% on two different days and pooled together. The COHb and MetHb were measured with a blood gas-analyzer and simultaneously with the Rad-57 as the COHb increased from 1.4 to 14%. Results were compared using linear regression and a Bland and Altman method comparison. Mean bias and precision for COHb measured with the Rad-57 was -1% and 2.5%, respectively. The mean bias and precision for MetHb measured with the Rad-57 was 0.0% and 0.3%, respectively. The ability to detect a COHb ≥ 10% occurred in 54% of the samples in which COHb was ≥ 10-14%. In conclusion, the Rad-57 provides a reading that is between -6% and +4% of the true COHb value for 95% of all samples. The Rad-57 seems to be a good substitute as a first screening test of COHb when the pulse CO-oximeter reads <15%. Copyright © 2012 Elsevier B.V. All rights reserved.

  12. CHANGES IN MAIN VEIN CHARACTERISTICS OF COSMONAUT'S LOWER EXTREMITIES IN THE COURSE OF YEAR-LONG SPACE MISSIONS.

    PubMed

    Kotovskaya, A R; Fomina, G A

    Leg venous measurements were performed in two cosmonauts during the 379-d "Mir" mission (K-1 and 340-d ISS mission (K-2). The paper presents individual changes in venous capacity, distention and filling rate in the legs of these two cosmonauts, and 23 cosmonauts on 6-mos. missions as controls. In the first half of the year-long missions, changes in venous characteristics showed similar trends though had different dimensions. For instance, in K-1 increases in capacity and distention were more pronounced than in K-2. In the second half of the missions, the cosmonauts again displayed different changes in venous characteristics. In K-1 they all were unstable with episodes of simultaneous increases in venous capacity, distention and filling rate that were unfavorable for orthostatic stability (OS). Changes in the K-2 leg veins were less dramatic and detrimental to OS. Recovery of the pre-flight status of leg veins following the year-long missions took a longer time as compared with 6-mos. missions; the process was still incomplete by day 8 after landing. We surmise that in future one-year and longer missions the majority of cosmonauts are likely to have favorable changes in leg veins; however, untoward venous developments and consequent OS impairment must not be excluded.

  13. [Correlation between arterial and venous blood gas analysis parameters in patients with acute exacerbation of chronic obstructive pulmonary disease].

    PubMed

    Novović, Miloš; Topić, Vesna

    2012-01-01

    Arterial blood gas (ABG) analyses have an important role in the assessment and monitoring of the metabolic and oxygen status of patients with acute exacerbation of chronic obstructive pulmonary disease (COPD). Arterial puncture could have a lot of adverse effects, while sampling of venous blood is simpler and is not so invasive. The aim of this study was to evaluate whether venous blood gas (VBG) values of pH, partial pressure of carbon dioxide (PCO2), partial oxygen pressure (PO2), bicarbonate (HCO3), and venous and arterial blood oxygen saturation (SO2) can reliably predict ABG levels in patients with acute exacerbation of COPD. Forty-seven patients with a prior diagnosis of COPD were included in this prospective study. The patients with acute exacerbation of this disease were examined at the General Hospital EMS Department in Prijepolje. ABG samples were taken immediately after venous sampling, and both were analyzed. The Pearson correlation coefficients between arterial and venous parameters were 0.828, 0.877, 0.599, 0.896 and 0.312 for pH, PCO2, PO2, HCO3 and SO2, respectively. The statistically significant correlation between arterial and venous pH, PCO2 and HCO3, values was found in patients with acute exacerbation of COPD (p<0.001). When we cannot provide arterial blood for analysis, venous values of the pH, Pv,CO2 and HCO3 parameters can be an alternative to their arterial equivalents in the interpretation of the metabolic status in patients with acute exacerbation of COPD, while the values of venous Pv,O, and Sv,O2 cannot be used as predictors in the assessment of oxygen status of such patients.

  14. Deep venous thrombosis among diabetic patients in King Abdulaziz University (KAU) Hospital, Jeddah, Kingdom of Saudi Arabia.

    PubMed

    Alotaibi, Hanan Khalid; Abo El-Fetoh, Nagah Mohamed; MenwerAlanazi, Aseel; Alanazi, Omar Ayed; Alanazi, Abdullah Barghash; Alhowaish, Mohammed Ali; Alzahrani, Hussam Saeed Busays; Alshammari, Mashael Abdullah; ALrashidi, Rawan Fulayyih; Alblowi, Thikra Mohammed; Alqahtani, Sarah Jemal; Almaashi, Fatin Salem

    2017-09-01

    Deep venous thrombosis (DVT) is a major cause of morbidity and mortality among hospitalized patients worldwide and, simultaneously, the most preventable. Studies revealed several risk factors of deep venous thrombosis in hospitalized patients. to identify frequency and factors associated with occurrence of deep venous thrombosis among diabetic patients referred to King Abdulaziz University (KAU) Hospital, Jeddah, Kingdom of Saudi Arabia. This cross-sectional hospital-based study was conducted from June to December, 2016. All diabetic patients referred to the hospital departments and who were suspected to have deep venous thrombosis (DVT) and subjected to Doppler examination were included in the study. A questionnaire was designed to obtain data about deep venous thrombosis frequency among participants and factors associated with the development of deep venous thrombosis among them. Data was collected through face to face interviews with patients included in the study. We used SPSS version 16 for data analysis through descriptive statistics and Chi-square test. DVT was detected in 14.7 % of the examined patients. There were significant and positive associations between age and DVT (X 2 =10.13, p=0.03) and between ischemic heart disease and DVT (X 2 =1.628, p=0.043) with the development of deep venous thrombosis among the studied patients. On the other hand, gender, other comorbidities, history of previous DVT, being bed ridden and using orthopedic casting were not significantly associated with the occurrence of deep venous thrombosis among the participants. DVT development rate among the participants was 14.7 %. Aging was significantly associated with DVT occurrence. Most of the studied factors and comorbidities had no significant role in DVT development among participants and only ischemic heart disease was significantly associated with DVT development.

  15. Clinical features of venous insufficiency and the risk of venous thrombosis in older people.

    PubMed

    Engbers, Marissa J; Karasu, Alev; Blom, Jeanet W; Cushman, Mary; Rosendaal, Frits R; van Hylckama Vlieg, Astrid

    2015-11-01

    Venous thrombosis is common in older age, with an incidence of 0·5-1% per year in those aged >70 years. Stasis of blood flow is an important contributor to the development of thrombosis and may be due to venous insufficiency in the legs. The risk of thrombosis associated with clinical features of venous insufficiency, i.e., varicose veins, leg ulcers and leg oedema, obtained with a standardized interview was assessed in the Age and Thrombosis Acquired and Genetic risk factors in the Elderly (AT-AGE) study. The AT-AGE study is a case-control study in individuals aged 70 years and older (401 cases with a first-time venous thrombosis and 431 control subjects). We calculated odds ratios (ORs) and corresponding 95% confidence intervals (CI) adjusted for age, sex and study centre. Varicose veins and leg ulcer were associated with a 1·6-fold (95% CI 1·2-2·3) and 3·3-fold increased risk of thrombosis (95% CI 1·6-6·7), respectively, while the risk was increased 3·0-fold (95% CI 2·1-4·5) in the presence of leg oedema. The risk of thrombosis was highest when all three risk factors occurred simultaneously (OR: 10·5; 95% CI 1·3-86·1). In conclusion, clinical features of venous insufficiency, i.e., varicose veins, leg ulcers and leg oedema, are risk factors for venous thrombosis in older people. © 2015 John Wiley & Sons Ltd.

  16. Selective parathyroid venous sampling in primary hyperparathyroidism: A systematic review and meta-analysis.

    PubMed

    Ibraheem, Kareem; Toraih, Eman A; Haddad, Antoine B; Farag, Mahmoud; Randolph, Gregory W; Kandil, Emad

    2018-05-14

    Minimally invasive parathyroidectomy requires accurate preoperative localization techniques. There is considerable controversy about the effectiveness of selective parathyroid venous sampling (sPVS) in primary hyperparathyroidism (PHPT) patients. The aim of this meta-analysis is to examine the diagnostic accuracy of sPVS as a preoperative localization modality in PHPT. Studies evaluating the diagnostic accuracy of sPVS for PHPT were electronically searched in the PubMed, EMBASE, Web of Science, and Cochrane Controlled Trials Register databases. Two independent authors reviewed the studies, and revised quality assessment of diagnostic accuracy study tool was used for the quality assessment. Study heterogeneity and pooled estimates were calculated. Two hundred and two unique studies were identified. Of those, 12 studies were included in the meta-analysis. Pooled sensitivity, specificity, and positive likelihood ratio (PLR) of sPVS were 74%, 41%, and 1.55, respectively. The area-under-the-receiver operating characteristic curve was 0.684, indicating an average discriminatory ability of sPVS. On comparison between sPVS and noninvasive imaging modalities, sensitivity, PLR, and positive posttest probability were significantly higher in sPVS compared to noninvasive imaging modalities. Interestingly, super-selective venous sampling had the highest sensitivity, accuracy, and positive posttest probability compared to other parathyroid venous sampling techniques. This is the first meta-analysis to examine the accuracy of sPVS in PHPT. sPVS had higher pooled sensitivity when compared to noninvasive modalities in revision parathyroid surgery. However, the invasiveness of this technique does not favor its routine use for preoperative localization. Super-selective venous sampling was the most accurate among all other parathyroid venous sampling techniques. Laryngoscope, 2018. © 2018 The American Laryngological, Rhinological and Otological Society, Inc.

  17. Superficial venous reflux duration and cessation with two concurrent duplex probes.

    PubMed

    Lattimer, Christopher R; Mendoza, Erika

    2015-04-01

    Venous reflux is the principal hemodynamic disorder and therapeutic target in patients with superficial venous insufficiency. To date, no studies have identified where or when it stops, anatomically or regionally, along the course of the refluxive conduit. Duplex measurements of reflux are performed invariably with a single probe. Because many anatomic locations are studied, repeated provocation maneuvers are required. However, this fails to appreciate reflux as a circulation. The use of two probes placed concurrently in different regions may address this limitation. The study compared venous reflux duration and cessation, above the knee and below the knee simultaneously, with two duplex probes. Seventeen legs from 17 consecutive patients (12 female, nine left) with great saphenous vein reflux were studied. Their median (range) age was 51 (28-71) years; weight, 76.8 (63.5-189) kg; height, 169 (153-180) cm; and Venous Clinical Severity Score, 5 (1-12). The clinical class of the Clinical, Etiologic, Anatomic, and Pathophysiologic (CEAP) classification was as follows: C2, 6; C3, 4; C4a, 5; and C4b, 2. After 2 minutes of elevation, the leg was assessed for reflux duration with duplex ultrasound. This occurred when the patient stood up during venous filling. One probe was positioned 10 cm below the saphenofemoral junction over the great saphenous vein (point A) and the other over a refluxive saphenous vein or tributary below the knee (point B). Concurrent images were displayed on adjacent monitors and recorded by a single video camera. Reflux duration was from the onset of dependency, indicated by the start of the video, to the termination of the red color (reflux) on video playback. The probes were swapped to negate for differences in machine sensitivity. Each leg was tested three times. Simultaneous was defined when there was <0.1 second difference between the two sites. The median (range) vein diameters at points A and B were 6.1 (2.8-9.3) mm and 5.5 (2.5-8.1) mm, respectively, with an intertransducer distance of 41 (23-59) cm. There was no significant difference in reflux duration between point A with 27 (9-150) seconds and point B with 27 (10-149) seconds (P = .943 [Wilcoxon]). The correlation was excellent (r = .986; P < .0005 [Spearman]). This is the first study to investigate reflux cessation by introducing a novel two-probe technique. It has demonstrated that reflux may stop simultaneously above and below the knee with use of the elevation to dependency maneuver to provoke reflux. It has shown that either site may be used to measure reflux duration. Furthermore, the two-probe technique confirms the belief that the mechanism of refluxive venous filling is through the descending path of a recirculation circuit. Copyright © 2015 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  18. Simultaneous acute deep vein thrombosis and acute brucellosis. A case report.

    PubMed

    Salihi, Salih; Andaç, Şeyda; Kalender, Mehmet; Yıldırım, Onur; İmre, Ayfer

    2016-06-01

    Brucellosis is a zoonotic disease common in developing countries. Vascular complications, including arterial and venous, associated with Brucella infection have rarely been reported. A case of deep venous thrombosis (DVT) developing after a diagnosis of acute brucellosis in a young milkman is presented. A 26-year-old man presented with pain in the right leg. The patient's medical history included a diagnosis of brucellosis in our hospital where he had presented with complaints of weakness and fever. Peripheral venous Doppler ultrasound showed DVT, and the patient was treated with anticoagulants. The patient was discharged with warfarin therapy and anti-brucellosis treatment. Although rare, some infectious agents may cause vascular pathologies. Patients presenting with symptoms of DVT or similar vascular pathologies should be assessed for infectious agents, particularly in those coming from Brucella-endemic areas.

  19. Epileptogenic developmental venous anomaly: insights from simultaneous EEG/fMRI.

    PubMed

    Scheidegger, Olivier; Wiest, Roland; Jann, Kay; König, Thomas; Meyer, Klaus; Hauf, Martinus

    2013-04-01

    Developmental venous anomalies (DVAs) are associated with epileptic seizures; however, the role of DVA in the epileptogenesis is still not established. Simultaneous interictal electroencephalogram/functional magnetic resonance imaging (EEG/fMRI) recordings provide supplementary information to electroclinical data about the epileptic generators, and thus aid in the differentiation of clinically equivocal epilepsy syndromes. The main objective of our study was to characterize the epileptic network in a patient with DVA and epilepsy by simultaneous EEG/fMRI recordings. A 17-year-old woman with recently emerging generalized tonic-clonic seizures, and atypical generalized discharges, was investigated using simultaneous EEG/fMRI at the university hospital. Previous high-resolution MRI showed no structural abnormalities, except a DVA in the right frontal operculum. Interictal EEG recordings showed atypical generalized discharges, corresponding to positive focal blood oxygen level dependent (BOLD) correlates in the right frontal operculum, a region drained by the DVA. Additionally, widespread cortical bilateral negative BOLD correlates in the frontal and parietal lobes were delineated, resembling a generalized epileptic network. The EEG/fMRI recordings support a right frontal lobe epilepsy, originating in the vicinity of the DVA, propagating rapidly to both frontal and parietal lobes, as expressed on the scalp EEG by secondary bilateral synchrony. The DVA may be causative of focal epilepsies in cases where no concomitant epileptogenic lesions can be detected. Advanced imaging techniques, such as simultaneous EEG/fMRI, may thus aid in the differentiation of clinically equivocal epilepsy syndromes.

  20. Factors affecting the performance of 5 cerebral oximeters during hypoxia in healthy volunteers.

    PubMed

    Bickler, Philip E; Feiner, John R; Rollins, Mark D

    2013-10-01

    Cerebral oximetry is a noninvasive optical technology that measures frontal cortex blood hemoglobin-oxygen saturation. Commercially available cerebral oximeters have not been evaluated independently. Unlike pulse oximeters, there are currently no Food and Drug Administration standards for performance or accuracy. We tested the hypothesis that cerebral oximeters accurately measure a fixed ratio of the oxygen saturation in cerebral mixed venous and arterial blood. We evaluated the performance of 5 commercially available cerebral oximeters: the EQUANOX® 7600 in 3- and 4-wavelength versions (Nonin Medical, Plymouth, MN), FORE-SIGHT® (Casmed, Branford, CT), INVOS® 5100C (Covidien, Boulder, CO), and the NIRO-200NX® (Hamamatsu Photonics, Hamamatsu City, Japan) during stable isocapnic hypoxia in volunteers. Twenty-three healthy adults (14 men, 9 women) had sensors placed on each side of the forehead. The subject's inspired oxygen (FIO2) was then changed to produce 6 steady-state arterial oxygen saturation (SaO2) levels between 100% and 70%, while end-tidal CO2 was maintained constant. At each plateau, simultaneous blood samples from the jugular bulb and radial artery were analyzed with a hemoximeter (OSM-3, Radiometer Medical A/S, Copenhagen, Denmark). Each cerebral oximeter's bias was calculated as the difference between the instrument's reading (cerebral saturation, ScO2) with the weighted saturation of venous and arterial blood (Sa/vO2), as specified by each manufacturer (INVOS: 25% arterial/75% venous; FORE-SIGHT, EQUANOX, and NIRO: 30% arterial/70% venous). Five hundred forty-two comparisons between paired blood samples and oximeter readings were analyzed. The pooled root mean square error was 8.06%, a value higher than for pulse oximeters, which is ±3% by Food and Drug Administration standards. The mean % bias ± SD (precision) and root mean square errors were: FORE-SIGHT 1.76 ± 3.92 and 4.28; INVOS 0.05 ± 9.72 and 9.69; NIRO-200NX -1.13 ± 9.64 and 9.68; EQUANOX-3 λ 2.48 ± 8.12 and 8.47; EQUANOX-4 λ 2.84 ± 6.27 and 6.86. The FORE-SIGHT, NIRO-200NX, and EQUANOX-3 λ had significantly more positive bias at lower SaO2. The amount of bias during hypoxia was reduced when the bias was calculated on the basis of difference between oximeter reading and the arterial and mixed venous saturation difference rather than the weighted average of blood saturation, indicating that differences in the ratio between arterial and venous blood volumes account for some of the positive bias at low saturation. Dark skin pigment tended to produce more negative bias in all instruments but bias was significantly larger than zero only for the FORE-SIGHT oximeter. Bias was significantly more negative in women for INVOS and EQUANOX devices but not for the FORE-SIGHT device. While responsive to desaturation, cerebral oximeters exhibited large variation in reading errors between subjects, with mean bias possibly related to variations in the ratio of arterial and venous blood in the sampling area of the brain. This ratio is probably not fixed, as assumed by the manufacturers, but dynamically changes with hypoxia. Better understanding these factors could improve the performance of cerebral oximeters and help establish saturation or blood flow thresholds for brain well-being.

  1. Clinical Evaluation of the BD FACSPresto™ Near-Patient CD4 Counter in Kenya

    PubMed Central

    Angira, Francis; Akoth, Benta; Omolo, Paul; Opollo, Valarie; Bornheimer, Scott; Judge, Kevin; Tilahun, Henok; Lu, Beverly; Omana-Zapata, Imelda; Zeh, Clement

    2016-01-01

    Background The BD FACSPresto™ Near-Patient CD4 Counter was developed to expand HIV/AIDS management in resource-limited settings. It measures absolute CD4 counts (AbsCD4), percent CD4 (%CD4), and hemoglobin (Hb) from a single drop of capillary or venous blood in approximately 23 minutes, with throughput of 10 samples per hour. We assessed the performance of the BD FACSPresto system, evaluating accuracy, stability, linearity, precision, and reference intervals using capillary and venous blood at KEMRI/CDC HIV-research laboratory, Kisumu, Kenya, and precision and linearity at BD Biosciences, California, USA. Methods For accuracy, venous samples were tested using the BD FACSCalibur™ instrument with BD Tritest™ CD3/CD4/CD45 reagent, BD Trucount™ tubes, and BD Multiset™ software for AbsCD4 and %CD4, and the Sysmex™ KX-21N for Hb. Stability studies evaluated duration of staining (18–120-minute incubation), and effects of venous blood storage <6–24 hours post-draw. A normal cohort was tested for reference intervals. Precision covered multiple days, operators, and instruments. Linearity required mixing two pools of samples, to obtain evenly spaced concentrations for AbsCD4, total lymphocytes, and Hb. Results AbsCD4 and %CD4 venous/capillary (N = 189/ N = 162) accuracy results gave Deming regression slopes within 0.97–1.03 and R2 ≥0.96. For Hb, Deming regression results were R2 ≥0.94 and slope ≥0.94 for both venous and capillary samples. Stability varied within 10% 2 hours after staining and for venous blood stored less than 24 hours. Reference intervals results showed that gender—but not age—differences were statistically significant (p<0.05). Precision results had <3.5% coefficient of variation for AbsCD4, %CD4, and Hb, except for low AbsCD4 samples (<6.8%). Linearity was 42–4,897 cells/μL for AbsCD4, 182–11,704 cells/μL for total lymphocytes, and 2–24 g/dL for Hb. Conclusions The BD FACSPresto system provides accurate, precise clinical results for capillary or venous blood samples and is suitable for near-patient CD4 testing. Trial Registration ClinicalTrials.gov NCT02396355 PMID:27483008

  2. Comparison of EML 105 and advantage analysers measuring capillary versus venous whole blood glucose in neonates.

    PubMed

    McNamara, P J; Sharief, N

    2001-09-01

    Near-patient blood glucose monitoring is an essential component of neonatal intensive care but the analysers currently used are unreliable and inaccurate. The aim of this study was to compare a new glucose electrode-based analyser (EML 105) and a non-wipe reflectance photometry method (Advantage) as opposed to a recognized laboratory reference method (Hexokinase). We also investigated the effect of sample route and haematocrit on the accuracy of the glucose readings obtained by each method of analysis. Whole blood glucose concentrations ranging from 0 to 3.5 mmol/l were carefully prepared in a laboratory setting and blood samples from each respective solution were then measured by EML 105 and Advantage analysers. The results obtained were then compared with the corresponding plasma glucose reading obtained by the Hexokinase method, using linear regression analysis. An in vivo study was subsequently performed on 103 neonates, over a 1-y period, using capillary and venous whole blood samples. Whole blood glucose concentration was estimated from each sample using both analysers and compared with the corresponding plasma glucose concentration estimated by the Hexokinase method. Venous blood was centrifuged and haematocrit was estimated using standardized curves. The effect of haematocrit on the agreement between whole blood and plasma glucose was investigated, estimating the degree of correlation on a scatterplot of the results and linear regression analysis. Both the EML 105 and Hexokinase methods were highly accurate, in vitro, with small proportional biases of 2% and 5%, respectively. However, in vivo, both study analysers overestimated neonatal plasma glucose, ranging from at best 0.45 mmol/l (EML 105 venous) to 0.69 mmol/l (EML capillary). There was no significant difference in the agreement of capillary (GD = 0.12, 95% CI, [-0.32,0.08], p = 0.2) or venous samples (GD = 0.05, 95% CI. [0.09, 0.19], p = 0.49) with plasma glucose when analysed by either study method (GD = glucose difference between study analyser and reference method) However, the venous samples analysed by EML 105 estimated plasma glucose significantly better than capillary samples using the same method of analysis (GD = 0.24, 95% CI. [0.09,0.38], p < 0.01). The relationship between haematocrit and the resultant glucose differences was non-linear with correlation coefficients of r = -0.057 (EML 105 capillary), r = 0.145 (EML 105 venous), r = -0.127 (Advantage capillary) and r = -0.275 (Advantage venous). There was no significant difference in the effect of haematocrit on the performance of EML 105 versus Advantage, regardless of the sample route. Both EML 105 and Advantage overestimated plasma glucose, with no significant difference in the performance of either analyser, regardless of the route of analysis. Agreement with plasma glucose was better for venous samples but this was only statistically significant when EML 105 capillary and venous results were compared. Haematocrit is not a significant confounding factor towards the performance of either EML 105 or Advantage in neonates, regardless of the route of sampling. The margin of overestimation of blood glucose prohibits the recommendation of both EML 105 and Advantage for routine neonatal glucose screening. The consequences include failure accurately to diagnose hypoglycaemia and delays in the instigation of therapeutic measures, both of which may potentially result in an adverse, long-term, neurodevelopmental outcome.

  3. Simultaneous Iliac Vein Bovine Pericardial Patch Venoplasty and Creation of PTFE Lower Limb Arteriovenous Fistula Graft for Rescue Vascular Access.

    PubMed

    Meecham, Lewis; Fisher, Owain; Kirby, George; Evans, Richard; Buxton, Pauline; Legge, Jocelyn; Rajagopalan, Sriram; Asquith, John; Pherwani, Arun

    2016-10-01

    We present a case of external iliac vein patch venoplasty to accommodate rescue vascular access via a polytetrafluoroethylene loop arteriovenous fistula graft (AVG) for a patient with multiple central venous stenoses. A 35-year-old female with anti-glomerular basement membrane antibody disease required rescue vascular access for hemodialysis. Repeated occlusion and/or thrombosis of long-term central venous access cannulae, to facilitate dialysis, had caused stenosis of brachiocephalic veins: right external iliac vein and occlusion of the left common iliac vein. A previous right brachiobasilic fistula had occluded within 1 year. No other upper limb options for arteriovenous fistula (AVF) were available. A right external iliac vein bovine patch angioplasty concurrently with a polytetrafluoroethylene AV graft between common femoral artery and common femoral vein was performed to restore venous patency and allow rescue dialysis access. At 3-year follow-up, the fistula remains widely patent with 2 L/min flow rates and no recurrent stenosis to the treated iliac vein. She has not required any further surgical or interventional radiological procedures to maintain fistula or central venous patency. Central venous stenosis or occlusion is common for patients requiring dialysis, especially those with multiple previous long-term central venous cannulations. If restriction of outflow is present, AVF may fail. Venous patch angioplasty in these cases is a successful technique, allowing AVF formation and long-term patency. Central venous stenosis can be treated successfully with patch venoplasty to accommodate AVF/AVG formation for rescue vascular access; this is a potentially lifesaving intervention for patients requiring dialysis. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. [Participation of leucocytes in pathogenesis of primary forms of lower limb chronic venous disease].

    PubMed

    Bogachev, V Iu; Golovanova, O V; Sergeeva, N A; Kuznetsov, A N

    2011-01-01

    The purpose of the study was to test the hypothesis on participation of WBCs in damaging the venous wall in patients presenting with primary forms of lower limb chronic venous diseases LLCVD . The study included a total of fifteen consecutively selected patients (13 women and 2 men) diagnosed as having grade C2-C-4 LLCVD according to the CEAP classification. Static loading (30 minutes in the sitting position) was followed by simultaneous sampling of blood from the varicose vein of the cms and ulnar vein. The total blood count including determination of both the absolute values and percentage of blood formed elements was performed using the automated haematological counter «Advia 7» («Bayer», USA). The obtained findings were statistically processed using the Microsoft Office Excel software by means of the pared two-sample τ-test for the average values. The number of leukocytes and their subpopulations in blood samples obtained from the crural varicose veins turned out to be significantly less as compared with that in blood sampled from the ulnar vein. Thus, blood sampled from the crural varicose veins demonstrated a decrease in the counts of WBC by 9.6% in fourteen (93.3%) patients, that of neutrophils by 4.9% in twelve (80%) patients, that of lymphocytes by 16,8% in fifteen (100%) patients, and that oi monocytes by 24% in twelve (80%) patients. The mentioned differences were statistically significant at a = 0.05. The eosinophilic counts in blood sampled from the upper and lower extremities appeared similar in 66.7% of the examined subjects. In 33.3% of cases the eosinophilic count in blood samples from crural varicose vein was by 16.7% lower than that for blood samples form the ulnar vein. No differences for the rest parameters of the clinical blood count were revealed. The absolute lymphocytic count in the blood samples taken after the 30-minute static loading from the crural varicose veins was significantly lower as compared with that in blood sampled form the cubital vein. The counts for RBCs and blood platelets, as well as other qualitative haematological indices (haemoglobin, haematocrit, average volume of the RBC, erythrocytic diameter, etc.) in blood sampled form crural and ulnar veins in the same patient were identical, thus strongly suggesting the lack of either haemodynamic or haemorheological phenomena capable of leading to redistribution of the blood formed elements in varicose veins. Hence a decrease in the counts of leukocytes and their subpopulations in blood sampled from crural varicose veins might be associated with the «leukocytic trap» phenomenon.

  5. Relative value of computed tomography scanning and venous sampling in establishing the cause of primary hyperaldosteronism.

    PubMed

    Sheaves, R; Goldin, J; Reznek, R H; Chew, S L; Dacie, J E; Lowe, D G; Ross, R J; Wass, J A; Besser, G M; Grossman, A B

    1996-03-01

    The purpose of this study was to evaluate the relative merits of the postural stimulation test, adrenal computed tomography (CT) and venous sampling in the differential diagnosis of patients presenting with primary hyperaldosteronism. The records of 20 patients presenting with primary hyperaldosteronism were reviewed retrospectively. There were 15 patients with a unilateral aldosterone-producing adenoma (APA), four patients with idiopathic hyperaldosteronism (IHA) and one patient with primary adrenal hyperplasia (PAH). The postural stimulation test was based on measurements of plasma aldosterone and renin activity at 08.00 h and at noon after 4 h of ambulation. The CT scans of the adrenals were reviewed by a single radiologist. Bilateral venous sampling of adrenal veins was attempted in all patients and blood collected for aldosterone and cortisol assay. Plasma aldosterone concentration increased after 4 h of standing in all cases of hyperplasia but was also demonstrated in 10/15 patients with a surgically-proven APA. If one defines a significant postural rise as being greater than 30%, then 8/15 patients with APA can be considered as being posturally responsive. Computed tomography scanning correctly identified all 15 cases of APA and also classified correctly the remaining five cases of hyperplasia (four cases of IHA and one case of PAH). Venous sampling failed technically in 4/15 cases of APA and in one case of IHA: a total of 5/20 (25%,). A correct diagnosis of APA or IHA was established in all the remaining cases. However, the one case of PAH was treated successfully by adrenalectomy following venous sampling, which suggested a unilateral adrenal lesion: this one result was the only instance where venous sampling altered clinical decision-making. Computed tomography scanning may be used alone to confirm the cause of hyperaldosteronism where postural studies suggest an adrenal adenoma, and such patients may be considered for early surgery. Venous catheterization studies are not necessary routinely. but may still be useful in selected patients, particularly when CT scanning shows no clear lesion.

  6. Adrenal venous sampling in a patient with adrenal Cushing syndrome

    PubMed Central

    Villa-Franco, Carlos Andrés; Román-Gonzalez, Alejandro; Velez-Hoyos, Alejandro; Echeverri-Isaza, Santiago

    2015-01-01

    The primary bilateral macronodular adrenal hyperplasia or the independent adrenocorticotropic hormone bilateral nodular adrenal hyperplasia is a rare cause hypercortisolism, its diagnosis is challenging and there is no clear way to decide the best therapeutic approach. Adrenal venous sampling is commonly used to distinguish the source of hormonal production in patients with primary hyperaldosteronism. It could be a useful tool in this context because it might provide information to guide the treatment. We report the case of a patient with ACTH independent Cushing syndrome in whom the use of adrenal venous sampling with some modifications radically modified the treatment and allowed the diagnosis of a macronodular adrenal hyperplasia. PMID:26309345

  7. Hemoglobin measured by Hemocue and a reference method in venous and capillary blood: a validation study.

    PubMed

    Neufeld, Lynnette; García-Guerra, Armando; Sánchez-Francia, Domingo; Newton-Sánchez, Oscar; Ramírez-Villalobos, María Dolores; Rivera-Dommarco, Juan

    2002-01-01

    To assess the comparability of hemoglobin concentration (Hb) in venous and capillary blood measured by Hemocue and an automated spectrophotometer (Celldyn) and to document the influence of type of blood (capillary or venous) and analysis method on anemia prevalence estimates. Between February and May 2000, capillary and venous samples were collected from 72 adults and children at Hospital del Niño Morelense (Morelos State Children's Hospital) in Cuernavaca, Morelos, Mexico, and assessed for Hb using the Hemocue and Celldyn methods. Estimated Hb levels were compared using the concordance correlation coefficient and Student's t test for paired data. The sensitivity and specificity for anemia diagnosis were estimated and compared between type of blood and method of assessment. Capillary blood had higher Hb (+0.5 g/dl) than venous blood in adults and children, as did samples assessed by Celldyn compared to Hemocue (+0.3 g/dl). Specificity to detect anemia was adequate (> 0.90) but sensitivity was low for capillary blood assessed by Hemocue (< 0.80). The difference in Hb between venous and capillary blood is likely related to biological variability. Hemoglobin concentration in capillary blood assessed by Hemocue provides an adequate estimation of population anemia prevalence but may result in excess false negative diagnoses among individuals. The results of this study stress the importance of sample collection technique, particularly for children. Method of analysis and sampling site need to be taken into consideration in field studies. The English version of this paper is available too at: http://www.insp.mx/salud/index.html.

  8. Effect of changes in PCO2 and body positions on intraocular pressure during general anaesthesia.

    PubMed

    Hvidberg, A; Kessing, S V; Fernandes, A

    1981-08-01

    Elevated arterial carbon dioxide tension, induced by the administration of CO2 via the respiratory air or by hypoventilation, entailed a gradual increase in the IOP in patients without eye diseases under general anaesthesia. A sudden cessation of CO2 administration or hyperventilation caused such a rapid, simultaneous fall in IOP to values below the initial level that the pressure variations must be of vascular nature, presumably related to changes in choroidal blood volume. The above-mentioned procedures always cause a change in the central venous pressure (CVP) simultaneously with the IOP changes. Alterations of the CVP induced by hydrostatic factors in postural changes, placing the head 15 degrees above or below the horizontal level while keeping the PaCO2 constant, caused IOP changes of the same configuration and magnitude as described above. It is concluded, therefore, that presumably the CO2-conditioned IOP changes are due predominantly to changes in central venous pressure, being one link in a CO2-conditioned action upon the general circulation, entailing passive secondary changes in the choroidal venous blood volume and thereby an influence upon the IOP. On the basis of the present results it appears rational to recommend hyperventilation to keep the PaCO2 between 25 and 30 mm and a 15 degree anti-Trendelenburg position in operations on the eye under general anaesthesia, since both procedures afford a low central venous pressure and consequently a low pressure in the posterior segment of the eye, with its attendant advantages as regards vitreous complications and the insertion of intraocular lenses. Owing to the risk of an unacceptable fall in BP in the combined procedure, a frequent checking of the BP is needed.

  9. Doppler echo evaluation of pulmonary venous-left atrial pressure gradients: human and numerical model studies

    NASA Technical Reports Server (NTRS)

    Firstenberg, M. S.; Greenberg, N. L.; Smedira, N. G.; Prior, D. L.; Scalia, G. M.; Thomas, J. D.; Garcia, M. J.

    2000-01-01

    The simplified Bernoulli equation relates fluid convective energy derived from flow velocities to a pressure gradient and is commonly used in clinical echocardiography to determine pressure differences across stenotic orifices. Its application to pulmonary venous flow has not been described in humans. Twelve patients undergoing cardiac surgery had simultaneous high-fidelity pulmonary venous and left atrial pressure measurements and pulmonary venous pulsed Doppler echocardiography performed. Convective gradients for the systolic (S), diastolic (D), and atrial reversal (AR) phases of pulmonary venous flow were determined using the simplified Bernoulli equation and correlated with measured actual pressure differences. A linear relationship was observed between the convective (y) and actual (x) pressure differences for the S (y = 0.23x + 0.0074, r = 0.82) and D (y = 0.22x + 0.092, r = 0.81) waves, but not for the AR wave (y = 0. 030x + 0.13, r = 0.10). Numerical modeling resulted in similar slopes for the S (y = 0.200x - 0.127, r = 0.97), D (y = 0.247x - 0. 354, r = 0.99), and AR (y = 0.087x - 0.083, r = 0.96) waves. Consistent with numerical modeling, the convective term strongly correlates with but significantly underestimates actual gradient because of large inertial forces.

  10. Doppler echo evaluation of pulmonary venous-left atrial pressure gradients: human and numerical model studies.

    PubMed

    Firstenberg, M S; Greenberg, N L; Smedira, N G; Prior, D L; Scalia, G M; Thomas, J D; Garcia, M J

    2000-08-01

    The simplified Bernoulli equation relates fluid convective energy derived from flow velocities to a pressure gradient and is commonly used in clinical echocardiography to determine pressure differences across stenotic orifices. Its application to pulmonary venous flow has not been described in humans. Twelve patients undergoing cardiac surgery had simultaneous high-fidelity pulmonary venous and left atrial pressure measurements and pulmonary venous pulsed Doppler echocardiography performed. Convective gradients for the systolic (S), diastolic (D), and atrial reversal (AR) phases of pulmonary venous flow were determined using the simplified Bernoulli equation and correlated with measured actual pressure differences. A linear relationship was observed between the convective (y) and actual (x) pressure differences for the S (y = 0.23x + 0.0074, r = 0.82) and D (y = 0.22x + 0.092, r = 0.81) waves, but not for the AR wave (y = 0. 030x + 0.13, r = 0.10). Numerical modeling resulted in similar slopes for the S (y = 0.200x - 0.127, r = 0.97), D (y = 0.247x - 0. 354, r = 0.99), and AR (y = 0.087x - 0.083, r = 0.96) waves. Consistent with numerical modeling, the convective term strongly correlates with but significantly underestimates actual gradient because of large inertial forces.

  11. Use of plasma metanephrine to aid adrenal venous sampling in combined aldosterone and cortisol over-secretion.

    PubMed

    Goupil, Rémi; Wolley, Martin; Ungerer, Jacobus; McWhinney, Brett; Mukai, Kuniaki; Naruse, Mitsuhide; Gordon, Richard D; Stowasser, Michael

    2015-01-01

    In patients with primary aldosteronism (PA) undergoing adrenal venous sampling (AVS), cortisol levels are measured to assess lateralization of aldosterone overproduction. Concomitant adrenal autonomous cortisol and aldosterone secretion therefore have the potential to confound AVS results. We describe a case where metanephrine was measured during AVS to successfully circumvent this problem. A 55-year-old hypertensive male had raised plasma aldosterone/renin ratios and PA confirmed by fludrocortisone suppression testing. Failure of plasma cortisol to suppress overnight following dexamethasone and persistently suppressed corticotrophin were consistent with adrenal hypercortisolism. On AVS, comparison of adrenal and peripheral A/F ratios (left 5.7 vs peripheral 1.0; right 1.7 vs peripheral 1.1) suggested bilateral aldosterone production, with the left gland dominant but without contralateral suppression. However, using aldosterone/metanephrine ratios (left 9.7 vs peripheral 2.4; right 1.3 vs peripheral 2.5), aldosterone production lateralized to the left with good contralateral suppression. The patient underwent left laparoscopic adrenalectomy with peri-operative glucocorticoid supplementation to prevent adrenal insufficiency. Pathological examination revealed adrenal cortical adenomas producing both cortisol and aldosterone within a background of aldosterone-producing cell clusters. Hypertension improved and cured of PA and hypercortisolism were confirmed by negative post-operative fludrocortisone suppression and overnight 1 mg dexamethasone suppression testing. Routine dexamethasone suppression testing in patients with PA permits detection of concurrent hypercortisolism which can confound AVS results and cause unilateral PA to be misdiagnosed as bilateral with patients thereby denied potentially curative surgical treatment. In such patients, measurement of plasma metanephrine during AVS may overcome this issue. Simultaneous autonomous overproduction of cortisol and aldosterone is increasingly recognised although still apparently uncommon.Because cortisol levels are used during AVS to correct for differences in dilution of adrenal with non-adrenal venous blood when assessing for lateralisation, unilateral cortisol overproduction with contralateral suppression could confound the interpretation of AVS resultsMeasuring plasma metanephrine during AVS to calculate lateralisation ratios may circumvent this problem.

  12. Recurrent epistaxis from Kiesselbach area syndrome in patients suffering from hemorrhoids: fact or fiction?

    PubMed

    Mladina, Ranko; Cavcic, Josip; Subaric, Marin

    2002-01-01

    It has been found that >90% of patients suffering from recurrent epistaxis from Kiesselbach area syndrome (REKAS) simultaneously suffered from hemorrhoids. To clarify this, the authors decided to investigate in the opposite direction, i.e., to find out whether or not REKAS occurs in patients suffering primarily from hemorrhoids. The study group included 53 randomly selected hospitalized patients with hemorrhoidal disorder (31 males and 22 females: age range 18-57 years). A search for essential clinical signs of REKAS was performed in each patient. Incidence was not high, although all clinical parameters were nearly the same: dilated vessels in Kiesselbach venous plexus (83.01%) and a positive hereditary factor (92.7%). The only missing factor in patients with hemorrhoids was anterior septal deformity, so frequent in REKAS patients. CONCLUSIONS; The authors conclude that REKAS and hemorrhoidal syndrome are separate clinical entities that are characterized by dilated vessels of similar venous plexus and simultaneous appearance in the same patient or close relatives.

  13. A study on new method of noninvasive esophageal venous pressure measurement based on the airflow and laser detection technology.

    PubMed

    Hu, Chenghuan; Huang, Feizhou; Zhang, Rui; Zhu, Shaihong; Nie, Wanpin; Liu, Xunyang; Liu, Yinglong; Li, Peng

    2015-01-01

    Using optics combined with automatic control and computer real-time image detection technology, a novel noninvasive method of noncontact pressure manometry was developed based on the airflow and laser detection technology in this study. The new esophageal venous pressure measurement system was tested in-vitro experiments. A stable and adjustable pulse stream was produced from a self-developed pump and a laser emitting apparatus could generate optical signals which can be captured by image acquisition and analysis system program. A synchronization system simultaneous measured the changes of air pressure and the deformation of the vein wall to capture the vascular deformation while simultaneously record the current pressure value. The results of this study indicated that the pressure values tested by the new method have good correlation with the actual pressure value in animal experiments. The new method of noninvasive pressure measurement based on the airflow and laser detection technology is accurate, feasible, repeatable and has a good application prospects.

  14. CD4 Lymphocyte Enumeration and Hemoglobin Assessment Aid for Priority Decisions: A Multisite Evaluation of the BD FACSPresto™ System

    PubMed Central

    Thakar, Madhuri; Angira, Francis; Pattanapanyasat, Kovit; Wu, Alan H.B.; O’Gorman, Maurice; Zeng, Hui; Qu, Chenxue; Mahajan, Bharati; Sukapirom, Kasama; Chen, Danying; Hao, Yu; Gong, Yan; Indig, Monika De Arruda; Graminske, Sharon; Orta, Diana; d’Empaire, Nicole; Lu, Beverly; Omana-Zapata, Imelda; Zeh, Clement

    2017-01-01

    Background: The BD FACSPresto™ system uses capillary and venous blood to measure CD4 absolute counts (CD4), %CD4 in lymphocytes, and hemoglobin (Hb) in approximately 25 minutes. CD4 cell count is used with portable CD4 counters in resource-limited settings to manage HIV/AIDS patients. A method comparison was performed using capillary and venous samples from seven clinical laboratories in five countries. The BD FACSPresto system was assessed for variability between laboratory, instrument/operators, cartridge lots and within-run at four sites. Methods: Samples were collected under approved voluntary consent. EDTA-anticoagulated venous samples were tested for CD4 and %CD4 T cells using the gold-standard BD FACSCalibur™ system, and for Hb, using the Sysmex® KX-21N™ analyzer. Venous and capillary samples were tested on the BD FACSPresto system. Matched data was analyzed for bias (Deming linear regression and Bland-Altman methods), and for concordance around the clinical decision point. The coefficient of variation was estimated per site, instrument/operator, cartridge-lot and between-runs. Results: For method comparison, 93% of the 720 samples were from HIV-positive and 7% from HIV-negative or normal subjects. CD4 and %CD4 T cells venous and capillary results gave slopes within 0.96–1.05 and R2 ≥0.96; Hb slopes were ≥1.00 and R2 ≥0.89. Variability across sites/operators gave %CV <5.8% for CD4 counts, <1.9% for %CD4 and <3.2% for Hb. The total %CV was <7.7% across instrument/cartridge lot. Conclusion: The BD FACSPresto system provides accurate, reliable, precise CD4/%CD4/Hb results compared to gold-standard methods, irrespective of venous or capillary blood sampling. The data showed good agreement between the BD FACSPresto, BD FACSCalibur and Sysmex systems. PMID:29290885

  15. CD4 Lymphocyte Enumeration and Hemoglobin Assessment Aid for Priority Decisions: A Multisite Evaluation of the BD FACSPresto™ System.

    PubMed

    Thakar, Madhuri; Angira, Francis; Pattanapanyasat, Kovit; Wu, Alan H B; O'Gorman, Maurice; Zeng, Hui; Qu, Chenxue; Mahajan, Bharati; Sukapirom, Kasama; Chen, Danying; Hao, Yu; Gong, Yan; Indig, Monika De Arruda; Graminske, Sharon; Orta, Diana; d'Empaire, Nicole; Lu, Beverly; Omana-Zapata, Imelda; Zeh, Clement

    2017-01-01

    The BD FACSPresto ™ system uses capillary and venous blood to measure CD4 absolute counts (CD4), %CD4 in lymphocytes, and hemoglobin (Hb) in approximately 25 minutes. CD4 cell count is used with portable CD4 counters in resource-limited settings to manage HIV/AIDS patients. A method comparison was performed using capillary and venous samples from seven clinical laboratories in five countries. The BD FACSPresto system was assessed for variability between laboratory, instrument/operators, cartridge lots and within-run at four sites. Samples were collected under approved voluntary consent. EDTA-anticoagulated venous samples were tested for CD4 and %CD4 T cells using the gold-standard BD FACSCalibur ™ system, and for Hb, using the Sysmex ® KX-21N ™ analyzer. Venous and capillary samples were tested on the BD FACSPresto system. Matched data was analyzed for bias (Deming linear regression and Bland-Altman methods), and for concordance around the clinical decision point. The coefficient of variation was estimated per site, instrument/operator, cartridge-lot and between-runs. For method comparison, 93% of the 720 samples were from HIV-positive and 7% from HIV-negative or normal subjects. CD4 and %CD4 T cells venous and capillary results gave slopes within 0.96-1.05 and R 2 ≥0.96; Hb slopes were ≥1.00 and R 2 ≥0.89. Variability across sites/operators gave %CV <5.8% for CD4 counts, <1.9% for %CD4 and <3.2% for Hb. The total %CV was <7.7% across instrument/cartridge lot. The BD FACSPresto system provides accurate, reliable, precise CD4/%CD4/Hb results compared to gold-standard methods, irrespective of venous or capillary blood sampling. The data showed good agreement between the BD FACSPresto, BD FACSCalibur and Sysmex systems.

  16. Agreement of arterial sodium and arterial potassium levels with venous sodium and venous potassium in patients admitted to intensive care unit.

    PubMed

    Nanda, Sunil Kumar; Ray, Lopamudra; Dinakaran, Asha

    2015-02-01

    Electrolyte abnormalities are one of the common causes of morbidity and mortality in critically ill patients. The turnaround time for electrolyte reporting should be as low as possible. Electrolytes are measured conventionally in serum obtained from venous blood by electrolyte analyser which takes 20 to 30 min. Point of care analysers are now available where in electrolytes can be measured in arterial blood within 5 min. This study was done to study the agreement of arterial sodium and arterial potassium with venous sodium and venous potassium levels. Venous sodium and venous potassium levels and arterial sodium and arterial potassium levels were analysed on 206 patient samples admitted to Intensive Care Unit (ICU). The venous values were compared with the arterial values for correlation. Venous sodium was compared with arterial sodium by spearman correlation. Venous potassium was compared with arterial potassium by pearson correlation. The mean value of arterial sodium was 134 and venous sodium was 137. The mean value of arterial potassium was 3.6 and venous potassium was 4.1. The correlation coefficient obtained for sodium was 0.787 and correlation coefficient obtained for potassium was 0.701. There was positive correlation of arterial sodium and arterial potassium with venous sodium and venous potassium indicating agreement between the parameters. Arterial sodium and arterial potassium can be used instead of venous sodium and venous potassium levels in management of critically ill patients.

  17. Pharmacokinetic-pharmacodynamic study of subcutaneous injection of depot nandrolone decanoate using dried blood spots sampling coupled with ultrapressure liquid chromatography tandem mass spectrometry assays.

    PubMed

    Singh, Gurmeet K S; Turner, Leo; Desai, Reena; Jimenez, Mark; Handelsman, David J

    2014-07-01

    Testosterone (T) and nandrolone (N) esters require deep im injections by medical personnel but these often deposit injectate into sc fat so that more convenient sc self-administration may be feasible. To investigate the feasibility and pharmacology of sc injection of N decanoate in healthy men using dried blood spot (DBS) for frequent blood sampling without clinic visits. Healthy male volunteers received 100 mg N decanoate by a single sc injection. Finger-prick capillary blood was spotted onto filter paper before injection daily at home for 21 d and stored at room temperature. Venous whole blood was also spotted onto filter paper before and weekly for 3 wk after injection. DBS were extracted for assay of N and T by liquid chromatography tandem mass spectrometry in a single batch with serum concentrations estimated with adjustment for capillary blood sample volume and hematocrit to define peak (N) or nadir (T) time and concentration from individual daily measurements. Daily serum N peaked 2.50 ± 0.25 (SEM) ng/mL at a median (range) of 6 (4-13) days causing a reduction in serum T from 3.50 ± 0.57 ng/mL at baseline to a nadir of 0.38 ± 0.13 (SEM) ng/mL (89 ± 3% suppression) at a median (range) of 8 (5-16) days. Simultaneously sampled capillary, venous whole blood, and serum gave almost identical results for serum T and N. Finger-pricks and sc injections were well tolerated. This study demonstrates that A) DBS sampling with liquid chromatography mass spectrometry steroid analysis achieves frequent time sampling in the community without requiring clinic visits, venesection, or frozen serum storage, and B) androgen esters in an oil vehicle can be delivered effectively by sc injection, thus avoiding the need for medically supervised deep-im injections.

  18. Adrenal venous sampling in primary aldosteronism: multinomial regression modeling to detect aldosterone secretion lateralization when right adrenal sampling is missing.

    PubMed

    Durivage, Camille; Blanchette, Rémi; Soulez, Gilles; Chagnon, Miguel; Gilbert, Patrick; Giroux, Marie-France; Bourdeau, Isabelle; Oliva, Vincent L; Lacroix, André; Therasse, Eric

    2017-02-01

    Difficulty to recognize or canulate the right adrenal vein is the most frequent cause of adrenal venous sampling (AVS) failure. We aimed to assess multinomial regression modeling (MRM) of peripheral and left adrenal vein samplings to detect lateralization of aldosterone secretion when the right AVS is missing. Simultaneous bilateral AVS samplings were performed before (basal) and after intravenous cosyntropin injection in 188 consecutive patients between December 1989 and September 2015. Different reference standards for lateralization of aldosterone secretion were defined for basal and for postcosyntropin AVS and according to lateralization index cutoffs at least 2 and at least 4. MRMs were built to detect lateralization of aldosterone secretion according to these reference standards using only peripheral and left adrenal veins samplings (without the right AVS). Detection accuracy was assessed by the area under the receiver operating characteristic (AUROC) curves and detection sensitivities were reported for specificity at least 95%. For basal AVS with lateralization index at least 2, AUROC were respectively 0.931 [95% confidence interval (CI) 0.894-0.968] and 0.922 (95% CI 0.882-0.962) for right and left lateralization of aldosterone secretion detection and MRM could detect respectively 65.5 and 62.7% of the right and left lateralization of aldosterone secretion. For AVS after cosyntropin with lateralization index at least 4, AUROC were respectively 0.964 (95% CI: 0.940-0.987) and 0.955 (95% CI: 0.927-0.983) for right and left lateralization of aldosterone secretion, and MRM could detect respectively 77.2 and 72.9% of the right and left lateralization of aldosterone secretion. MRM can detect lateralization of aldosterone secretion without the right AVS in most patients and could eliminate the need for repeat AVS when right adrenal vein canulation is nonselective or impossible.

  19. Electrical foot stimulation and implications for the prevention of venous thromboembolic disease.

    PubMed

    Kaplan, Robert E; Czyrny, James J; Fung, Tat S; Unsworth, John D; Hirsh, Jack

    2002-08-01

    Venous stasis caused by immobility is an important risk factor for deep vein thrombosis following surgery and lower limb trauma, in bed-ridden medical patients, and in high-risk long distance air travelers. A safe and convenient method for reducing venous stasis would be useful in patients while in hospital and after discharge during their rehabilitation. 49 healthy subjects aged 51-76 were seated for 4 hours during which they received mild electrical stimulation of the calf, or sole of the foot (plantar muscles). Popliteal and femoral venous blood flow velocities were measured via doppler ultrasound. The non-stimulated lower extremity served as the simultaneous control. Subjects completed a questionnaire regarding their acceptance and tolerance of the electrical stimulation. There was a significant increase in venous femoral and popliteal blood flow for both calf (p < 0.035, p < 0.003), and plantar muscles (p < 0.0001, p < 0.009) on the stimulated side compared to the unstimulated side. The magnitude of the effect was similar for calf and plantar muscle stimulation. Subjects did not find the experience uncomfortable, and would use an electrical stimulator if told by their physician that they were at risk for developing blood clots. Mild electrical stimulation of the feet, as well as the calf, is a safe effective and convenient method for counteracting venous stasis and therefore has the potential to reduce the risk of deep vein thrombosis and pulmonary embolism for subjects who are immobilized.

  20. Transjugular Intrahepatic Portosystemic Shunt Creation in Budd-Chiari Syndrome: Percutaneous Ultrasound-Guided Direct Simultaneous Puncture of the Portal Vein and Vena Cava

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Boyvat, Fatih, E-mail: boyvatf@yahoo.com; Aytekin, Cueneyt; Harman, Ali

    Budd-Chiari syndrome (BCS) is an uncommon disorder that can be life-threatening, depending on the degree of hepatic venous outflow obstruction. Transjugular intrahepatic portosystemic shunt (TIPS) provides decompression of the congested liver but the hepatic vein obstruction makes the procedure more difficult. We describe a modified method that involved a single percutaneous puncture of the portal vein and inferior vena cava simultaneously for TIPS creation in a patient with BCS.

  1. Adrenal Venous Sampling: Where Is the Aldosterone Disappearing to?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Solar, Miroslav; Ceral, Jiri, E-mail: ceral.jiri@fnhk.c; Krajina, Antonin

    Adrenal venous sampling (AVS) is generally considered to be the gold standard in distinguishing unilateral and bilateral aldosterone hypersecretion in primary hyperaldosteronism. However, during AVS, we noticed a considerable variability in aldosterone concentrations among samples thought to have come from the right adrenal glands. Some aldosterone concentrations in these samples were even lower than in samples from the inferior vena cava. We hypothesized that the samples with low aldosterone levels were unintentionally taken not from the right adrenal gland, but from hepatic veins. Therefore, we sought to analyze the impact of unintentional cannulation of hepatic veins on AVS. Thirty consecutivemore » patients referred for AVS were enrolled. Hepatic vein sampling was implemented in our standardized AVS protocol. The data were collected and analyzed prospectively. AVS was successful in 27 patients (90%), and hepatic vein cannulation was successful in all procedures performed. Cortisol concentrations were not significantly different between the hepatic vein and inferior vena cava samples, but aldosterone concentrations from hepatic venous blood (median, 17 pmol/l; range, 40-860 pmol/l) were markedly lower than in samples from the inferior vena cava (median, 860 pmol/l; range, 460-4510 pmol/l). The observed difference was statistically significant (P < 0.001). Aldosterone concentrations in the hepatic veins are significantly lower than in venous blood taken from the inferior vena cava. This finding is important for AVS because hepatic veins can easily be mistaken for adrenal veins as a result of their close anatomic proximity.« less

  2. Hepatic venous pressure gradient after portal vein embolization: An accurate predictor of future liver remnant hypertrophy.

    PubMed

    Mohkam, Kayvan; Rode, Agnès; Darnis, Benjamin; Manichon, Anne-Frédérique; Boussel, Loïc; Ducerf, Christian; Merle, Philippe; Lesurtel, Mickaël; Mabrut, Jean-Yves

    2018-05-09

    The impact of portal hemodynamic variations after portal vein embolization on liver regeneration remains unknown. We studied the correlation between the parameters of hepatic venous pressure measured before and after portal vein embolization and future hypertrophy of the liver remnant after portal vein embolization. Between 2014 and 2017, we reviewed patients who were eligible for major hepatectomy and who had portal vein embolization. Patients had undergone simultaneous measurement of portal venous pressure and hepatic venous pressure gradient before and after portal vein embolization by direct puncture of portal vein and inferior vena cava. We assessed these parameters to predict future liver remnant hypertrophy. Twenty-six patients were included. After portal vein embolization, median portal venous pressure (range) increased from 15 (9-24) to 19 (10-27) mm Hg and hepatic venous pressure gradient increased from 5 (0-12) to 8 (0-14) mm Hg. Median future liver remnant volume (range) was 513 (299-933) mL before portal vein embolization versus 724 (499-1279) mL 3 weeks after portal vein embolization, representing a 35% (7.4-83.6) median hypertrophy. Post-portal vein embolization hepatic venous pressure gradient was the most accurate parameter to predict failure of future liver remnant to reach a 30% hypertrophy (c-statistic: 0.882 [95% CI: 0.727-1.000], P < 0.001). A cut-off value of post-portal vein embolization hepatic venous pressure gradient of 8 mm Hg showed a sensitivity of 91% (95% CI: 57%-99%), specificity of 80% (95% CI: 52%-96%), positive predictive value of 77% (95% CI: 46%-95%) and negative predictive value of 92.3% (95% CI: 64.0%-99.8%). On multivariate analysis, post-portal vein embolization hepatic venous pressure gradient and previous chemotherapy were identified as predictors of impaired future liver remnant hypertrophy. Post-portal vein embolization hepatic venous pressure gradient is a simple and reproducible tool which accurately predicts future liver remnant hypertrophy after portal vein embolization and allows early detection of patients who may benefit from more aggressive procedures inducing future liver remnant hypertrophy. (Surgery 2018;143:1-2.). Copyright © 2018 Elsevier Inc. All rights reserved.

  3. Dried Blood Spot Analysis Suitable for Therapeutic Drug Monitoring of Voriconazole, Fluconazole, and Posaconazole

    PubMed Central

    van der Elst, Kim C. M.; Span, Lambert F. R.; van Hateren, Kai; Vermeulen, Karin M.; van der Werf, Tjip S.; Greijdanus, Ben; Kosterink, Jos G. W.; Uges, Donald R. A.

    2013-01-01

    Invasive aspergillosis and candidemia are important causes of morbidity and mortality in immunocompromised and critically ill patients. The triazoles voriconazole, fluconazole, and posaconazole are widely used for the treatment and prophylaxis of these fungal infections. Due to the variability of the pharmacokinetics of the triazoles among and within individual patients, therapeutic drug monitoring is important for optimizing the efficacy and safety of antifungal treatment. A dried blood spot (DBS) analysis was developed and was clinically validated for voriconazole, fluconazole, and posaconazole in 28 patients. Furthermore, a questionnaire was administered to evaluate the patients' opinions of the sampling method. The DBS analytical method showed linearity over the concentration range measured for all triazoles. Results for accuracy and precision were within accepted ranges; samples were stable at room temperature for at least 12 days; and different hematocrit values and blood spot volumes had no significant influence. The ratio of the drug concentration in DBS samples to that in plasma was 1.0 for voriconazole and fluconazole and 0.9 for posaconazole. Sixty percent of the patients preferred DBS analysis as a sampling method; 15% preferred venous blood sampling; and 25% had no preferred method. There was significantly less perception of pain with the DBS sampling method (P = 0.021). In conclusion, DBS analysis is a reliable alternative to venous blood sampling and can be used for therapeutic drug monitoring of voriconazole, fluconazole, and posaconazole. Patients were satisfied with DBS sampling and had less pain than with venous sampling. Most patients preferred DBS sampling to venous blood sampling. PMID:23896473

  4. Validation of a simple HPLC-UV method for rifampicin determination in plasma: Application to the study of rifampicin arteriovenous concentration gradient.

    PubMed

    Goutal, Sébastien; Auvity, Sylvain; Legrand, Tiphaine; Hauquier, Fanny; Cisternino, Salvatore; Chapy, Hélène; Saba, Wadad; Tournier, Nicolas

    2016-05-10

    In clinical practice, rifampicin exposure is estimated from its concentration in venous blood samples. In this study, we hypothesized that differences in rifampicin concentration may exist between arterial and venous plasma. An HPLC-UV method for determining rifampicin concentration in plasma using rifapentine as an internal standard was validated. The method, which requires a simple protein precipitation procedure as sample preparation, was performed to compare venous and arterial plasma kinetics after a single therapeutic dose of rifampicin (8.6 mg/kg i.v, infused over 30 min) in baboons (n=3). The method was linear from 0.1 to 40 μg mL(-1) and all validation parameters fulfilled the international requirements. In baboons, rifampicin concentration in arterial plasma was higher than in venous plasma. Arterial Cmax was 2.1±0.2 fold higher than venous Cmax. The area under the curve (AUC) from 0 to 120 min was ∼80% higher in arterial plasma, indicating a significant arteriovenous concentration gradient in early rifampicin pharmacokinetics. Arterial and venous plasma concentrations obtained 6h after rifampicin injection were not different. An important arteriovenous equilibration delay for rifampicin pharmacokinetics is reported. Determination in venous plasma concentrations may considerably underestimate rifampicin exposure to organs during the distribution phase. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Closed-Loop Control of Fluid Therapy for Treatment of Hypovolemia

    DTIC Science & Technology

    2008-04-01

    index) (Table 2). Invasive bladder catheterization and blood sampling add the use of urinary output, lactate, central venous oxygen saturation, he...for guiding burn resuscitation Time delay, renal failure, and drugs complicate interpretation Central venous oxygenation ScvO2 Global perfusion index... Central venous pressure (CVP) Sensitive to volume change Pre-injury baseline values vary Arterial pressure by transducer Real-time continuous

  6. Use of giant-sized flow-through venous flap for simultaneous reconstruction of dual or multiple major arteries in salvage therapy for complex upper limb traumatic injury.

    PubMed

    Zheng, Da-Wei; Li, Zhang-Can; Shi, Rong-Jian; Sun, Feng; Xu, Li; Shou, Kui-Shui

    2016-02-01

    Salvage repair after complex upper limb traumatic injury is surgically challenging due to underlying major arterial impairment with complicating a large-sized soft tissue defect. The purpose of this study was to evaluate the effectiveness and safety of using a giant-sized (≥100 cm(2)) flow-through venous flap for reconstruction of dual or multiple forearm, metacarpal, or digital arteries after complex upper limb traumatic injury. Seven patients were consecutively hospitalized for emergency salvage repair after complex upper limb traumatic injury between March 2012 and May 2014. The forearm and palmar artery defects were repaired using the calf great saphenous vein flap and the volar forearm venous flap, respectively. The flow-through venous flap ranged from 9.5 cm × 12.0 cm to 12.0 cm × 20.0 cm (mean, 158.4 cm(2)) in size. The flaps and affected limbs survived uneventfully in five patients, with one patient experiencing distal flap marginal necrosis and a second patient requiring amputation of the affected limb. Computed tomography angiography showed patent vessels in all patients. The mean total active motion of the repaired fingers was 199.5° versus 258.8° for the contralateral counterpart (77.1%). The sensory return was determined to be S2 in 2 patients, S3 in 3 patients and S3+ in 1 patient. The disability scores for the arm, shoulder, and hand ranged from 4.6-18.2 (mean, 11.3), and the mean Michigan hand outcomes questionnaire score was 7.8 ± 0.9. The flow-through venous flap is an effective and safe treatment alternative for salvage therapy of a ≥100-cm(2) complex upper limb traumatic injury with dual or multiple major arterial impairment. This technique allows simultaneous reconstruction of dual or multiple artery injuries and an extensive soft tissue defect. Serious surgical site infection remains a major safety concern and necessitates radical debridement in complicating cases. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. A case of bilateral aldosterone-producing adenomas differentiated by segmental adrenal venous sampling for bilateral adrenal sparing surgery

    PubMed Central

    Morimoto, R; Satani, N; Iwakura, Y; Ono, Y; Kudo, M; Nezu, M; Omata, K; Tezuka, Y; Seiji, K; Ota, H; Kawasaki, Y; Ishidoya, S; Nakamura, Y; Arai, Y; Takase, K; Sasano, H; Ito, S; Satoh, F

    2016-01-01

    Primary aldosteronism due to unilateral aldosterone-producing adenoma (APA) is a surgically curable form of hypertension. Bilateral APA can also be surgically curable in theory but few successful cases can be found in the literature. It has been reported that even using successful adrenal venous sampling (AVS) via bilateral adrenal central veins, it is extremely difficult to differentiate bilateral APA from bilateral idiopathic hyperaldosteronism (IHA) harbouring computed tomography (CT)-detectable bilateral adrenocortical nodules. We report a case of bilateral APA diagnosed by segmental AVS (S-AVS) and blood sampling via intra-adrenal first-degree tributary veins to localize the sites of intra-adrenal hormone production. A 36-year-old man with marked long-standing hypertension was referred to us with a clinical diagnosis of bilateral APA. He had typical clinical and laboratory profiles of marked hypertension, hypokalaemia, elevated plasma aldosterone concentration (PAC) of 45.1 ng dl−1 and aldosterone renin activity ratio of 90.2 (ng dl−1 per ng ml−1 h−1), which was still high after 50 mg-captopril loading. CT revealed bilateral adrenocortical tumours of 10 and 12 mm in diameter on the right and left sides, respectively. S-AVS confirmed excess aldosterone secretion from a tumour segment vein and suppressed secretion from a non-tumour segment vein bilaterally, leading to the diagnosis of bilateral APA. The patient underwent simultaneous bilateral sparing adrenalectomy. Histopathological analysis of the resected adrenals together with decreased blood pressure and PAC of 5.2 ng dl−1 confirmed the removal of bilateral APA. S-AVS was reliable to differentiate bilateral APA from IHA by direct evaluation of intra-adrenal hormone production. PMID:26538381

  8. Comparability of HbA1c and lipids measured with dried blood spot versus venous samples: a systematic review and meta-analysis

    PubMed Central

    2014-01-01

    Background Levels of haemoglobin A1c (HbA1c) and blood lipids are important determinants of risk in patients with diabetes. Standard analysis methods based upon venous blood samples can be logistically challenging in resource-poor settings where much of the diabetes epidemic is occurring. Dried blood spots (DBS) provide a simple alternative method for sample collection but the comparability of data from analyses based on DBS is not well established. Methods We conducted a systematic review and meta-analysis to define the association of findings for HbA1c and blood lipids for analyses based upon standard methods compared to DBS. The Cochrane, Embase and Medline databases were searched for relevant reports and summary regression lines were estimated. Results 705 abstracts were found by the initial electronic search with 6 further reports identified by manual review of the full papers. 16 studies provided data for one or more outcomes of interest. There was a close agreement between the results for HbA1c assays based on venous and DBS samples (DBS = 0.9858venous + 0.3809), except for assays based upon affinity chromatography. Significant adjustment was required for assays of total cholesterol (DBS = 0.6807venous + 1.151) but results for triglycerides (DBS = 0.9557venous + 0.1427) were directly comparable. Conclusions For HbA1c and selected blood lipids, assays based on DBS samples are clearly associated with assays based on standard venous samples. There are, however, significant uncertainties about the nature of these associations and there is a need for standardisation of the sample collection, transportation, storage and analysis methods before the technique can be considered mainstream. This should be a research priority because better elucidation of metabolic risks in resource poor settings, where venous sampling is infeasible, will be key to addressing the global epidemic of cardiovascular diseases. PMID:25045323

  9. Alternating versus synchronous ventilation of left and right lungs in piglets.

    PubMed

    Versprille, A; Hrachovina, V; Jansen, J R

    1995-12-01

    We tested whether alternating ventilation (AV) of each lung (i.e. with a phase difference of half a ventilatory cycle) would decrease central venous pressure and so increase cardiac output when compared with simultaneous ventilation (SV) of both lungs. If, during AV, the inflated lung expands partly via compression of the opposite lung, mean lung volume will be smaller during AV than SV. As a consequence, mean intrathoracic pressure (as cited in the literature), and therefore, central venous pressure will be smaller. The experiments were performed in seven anaesthetized and paralyzed piglets using a double-piston ventilator. Minute ventilation was the same during AV and SV. Starting at SV, we alternated three times between AV and SV for periods of 10 min. During AV, central venous pressure was decreased by 0.7 mmHg and cardiac output was increased by 10 +/- 4.4% (mean, +/-SD) compared with SV. AV also resulted in increased arterial pressure. During one-sided inflation with closed outlet of the opposite lung, a pressure rise occurred in the opposite lung, indicating compression. The higher cardiac output during AV than SV can be explained by the fact that central venous pressure is lower during AV. This lower central venous pressure is very probably due to the lower mean intrathoracic pressure caused by compression of the opposite lung during unilateral inflation.

  10. Venous pooling and drainage affects photoplethysmographic signals at different vertical hand positions

    NASA Astrophysics Data System (ADS)

    Hickey, Michelle; Phillips, Justin P.; Kyriacou, Panayiotis

    2015-03-01

    The aim of the current work is to investigate the possibility of augmenting pulse oximetry algorithms to enable the estimation of venous parameters in peripheral tissues. In order to further understand the contribution of venous blood to the photoplethysmographic (PPG) signal, recordings were made from six healthy volunteer subjects during an exercise in which the right hand was placed in various positions above and below heart level. The left hand was kept at heart level as a control while the right hand was moved. A custom-made two-channel dual wavelength PPG instrumentation system was used to obtain the red and infrared plethysmographic signals from both the right and left index fingers simultaneously using identical sensors. Laser Doppler flowmetry signals were also recorded from an adjacent fingertip on the right hand. Analysis of all acquired PPG signals indicated changes in both ac and dc amplitude of the right hand when the position was changed, while those obtained from the left (control) hand remained relatively constant. Most clearly, in the change from heart level to 50cm below heart level there is a substantial decrease in both dc and ac amplitudes. This decrease in dc amplitude most likely corresponds to increased venous pooling, and hence increased absorption of light. It is speculated that the decrease in ac PPG amplitude is due to reduced arterial emptying during diastole due to increased downstream resistance due to venous pooling.

  11. Simultaneous Kidney-Pancreas Transplantation With an Original "Transverse Pancreas" Technique: Initial 9 Years' Experience With 56 Cases.

    PubMed

    Paulino, J; Martins, A; Vigia, E; Marcelino, P; Nobre, A M; Bicho, L; Filipe, E; Barroso, E

    2017-10-01

    An innovative technique for pancreas transplantation is described. The main aspect consists of the horizontal positioning of the pancreas, which allows a better venous outflow, thus preventing thrombosis and graft loss. The program of pancreas transplantation in this national reference center for pancreatic and liver surgery was started in 2007; the initial results were considered poor, resulting in the loss of half of the grafts due to venous thrombosis. After analyzing the possible causes, this technique was proposed and successfully implemented, reducing the postoperative complications, particularly the problem of venous thrombosis. A detailed description of the new surgical technique is provided. The main clinical and demographic characteristics of the 56 patients who underwent the surgery are analyzed. The incidence of venous thrombosis was 5.3% (3 patients) and graft loss was 3.5% (2 patients). Due to the good results, this technique became the standard surgery for transplantation of the pancreas in our center. The technique proved to be safe and successful. Due to the unique pancreas graft implantation, we called it "transverse pancreas surgery." Copyright © 2017 Elsevier Inc. All rights reserved.

  12. A New Procedure for Wrapped-Negative Pressure Wound Therapy for Congestion After Arterialized Venous Flap Surgery

    PubMed Central

    Niimi, Yosuke; Mori, Satoko; Takeuchi, Masaki

    2017-01-01

    Negative pressure wound therapy (NPWT) is a method for treating wound. However, there are no case reports using NPWT for treating congestion after arterialized venous flap. Therefore, this study reported favorable outcomes after using a single-use NPWT system for managing congestion. A 39-year-old man had his index finger caught by a press machine. The finger had a soft tissue defect at the ventral part. An arterialized venous flap taken from the right forearm was transplanted. Perfusion of the flap was favorable, but on postoperative day 5, congestion and the edema of the flap were found. Then, NPWT was initiated. The congestion and edema in the flap were improved without complications such as flap necrosis and wound infection. At 4 months postoperatively, the morphology of the finger was favorable. In this study, NPWT was speculated to force the deeper blood vessels within the flap to dilate with inducing drainage and the simultaneous reduction in excess blood flow to the cortical layer, resulting in the improvement of congestion. Negative pressure wound therapy was used for treating congestion after the transplantation of arterialized venous flap, and the wound was favorably managed. PMID:29270041

  13. Tricuspid regurgitation contributes to renal dysfunction in patients with heart failure.

    PubMed

    Maeder, Micha T; Holst, Diane P; Kaye, David M

    2008-12-01

    In heart failure (HF), renal dysfunction is associated with an adverse prognosis. Impaired renal perfusion from left ventricular dysfunction is thought to be a principal underlying mechanism. Less is known about the influence of venous congestion, including the potential contribution of tricuspid regurgitation (TR). Echocardiograms and a simultaneous (+/-1 day) blood sample from 196 HF patients were analyzed. Patients with at least moderate TR (n = 78) had larger right-sided cardiac cavities, higher right ventricular systolic pressure, lower estimated glomerular filtration rate (eGFR), higher serum urea nitrogen (SUN), and SUN/creatinine ratio than patients with less than moderate TR (n = 118). In multivariate linear regression analysis, TR severity (P = .003), older age (P < .001), and loop diuretic use (P = .008) were independently associated with lower eGFR, and use of inhibitors of the renin-angiotensin-aldosterone system was associated with higher eGFR (P = .001). TR severity (P < .001) and older age (P < .001) were independently associated with higher SUN. TR severity (P = .004) and smaller left ventricular end-diastolic diameter (P = .048) were independent predictors of a higher SUN/creatinine ratio (P = .004). Although a causal relationship cannot be proven, we suggest that significant TR contributes to renal dysfunction in HF patients, probably by elevation of central and renal venous pressure.

  14. D-Dimer and prothrombin fragment 1 + 2 in urine and plasma in patients with clinically suspected venous thromboembolism.

    PubMed

    Wexels, Fredrik; Seljeflot, Ingebjørg; Pripp, Are H; Dahl, Ola E

    2016-06-01

    Increased levels of urine prothrombin fragment 1 + 2 was recently reported to be associated with imaging-verified venous thromboembolism. In this study we evaluated the relationship between plasma D-dimer and plasma and urine prothrombin fragment 1 + 2 in patients with suspected venous thromboembolism. Urine and blood samples were collected from patients with suspected pulmonary embolism or deep vein thrombosis. The samples were analysed with commercially available ELISA kits. The diagnosis of venous thromboembolism was verified with contrast-enhanced computer tomography of the pulmonary arteries or lower extremity deep vein compression ultrasound and venography as appropriate. Venous thromboembolism was diagnosed in 150 of 720 patients. Significantly higher levels of plasma D-dimer and prothrombin fragment 1 + 2 in plasma and urine were found in those with imaging-confirmed venous thromboembolism versus those without (P < 0.001). The correlation between the three biomarkers was statistically significant (range of rs values 0.45-0.65, P < 0.001). Plasma D-dimer had the highest diagnostic accuracy followed by prothrombin fragment 1 + 2 in plasma. Further development of ELISA analyses for urine testing of prothrombin fragment 1 + 2 may improve its diagnostic accuracy.

  15. Cerebral venous blood oxygenation monitoring during hyperventilation in healthy volunteers with a novel optoacoustic system

    NASA Astrophysics Data System (ADS)

    Petrov, Andrey; Prough, Donald S.; Petrov, Irene Y.; Petrov, Yuriy; Deyo, Donald J.; Henkel, Sheryl N.; Seeton, Roger; Esenaliev, Rinat O.

    2013-03-01

    Monitoring of cerebral venous oxygenation is useful to facilitate management of patients with severe or moderate traumatic brain injury (TBI). Prompt recognition of low cerebral venous oxygenation is a key to avoiding secondary brain injury associated with brain hypoxia. In specialized clinical research centers, jugular venous bulb catheters have been used for cerebral venous oxygenation monitoring and have demonstrated that oxygen saturation < 50% (normal range is 55-75%) correlates with poor clinical outcome. We developed an optoacoustic technique for noninvasive monitoring of cerebral venous oxygenation. Recently, we designed and built a novel, medical grade optoacoustic system operating in the near-infrared spectral range for continuous, real-time oxygenation monitoring in the superior sagittal sinus (SSS), a large central cerebral vein. In this work, we designed and built a novel SSS optoacoustic probe and developed a new algorithm for SSS oxygenation measurement. The SSS signals were measured in healthy volunteers during voluntary hyperventilation, which induced changes in SSS oxygenation. Simultaneously, we measured exhaled carbon dioxide concentration (EtCO2) using capnography. Good temporal correlation between decreases in optoacoustically measured SSS oxygenation and decreases in EtCO2 was obtained. Decreases in EtCO2 from normal values (35-45 mmHg) to 20-25 mmHg resulted in SSS oxygenation decreases by 3-10%. Intersubject variability of the responses may relate to nonspecific brain activation associated with voluntary hyperventilation. The obtained data demonstrate the capability of the optoacoustic system to detect in real time minor changes in the SSS blood oxygenation.

  16. Combining image-derived and venous input functions enables quantification of serotonin-1A receptors with [carbonyl-11C]WAY-100635 independent of arterial sampling.

    PubMed

    Hahn, Andreas; Nics, Lukas; Baldinger, Pia; Ungersböck, Johanna; Dolliner, Peter; Frey, Richard; Birkfellner, Wolfgang; Mitterhauser, Markus; Wadsak, Wolfgang; Karanikas, Georgios; Kasper, Siegfried; Lanzenberger, Rupert

    2012-08-01

    image- derived input functions (IDIFs) represent a promising technique for a simpler and less invasive quantification of PET studies as compared to arterial cannulation. However, a number of limitations complicate the routine use of IDIFs in clinical research protocols and the full substitution of manual arterial samples by venous ones has hardly been evaluated. This study aims for a direct validation of IDIFs and venous data for the quantification of serotonin-1A receptor binding (5-HT(1A)) with [carbonyl-(11)C]WAY-100635 before and after hormone treatment. Fifteen PET measurements with arterial and venous blood sampling were obtained from 10 healthy women, 8 scans before and 7 after eight weeks of hormone replacement therapy. Image-derived input functions were derived automatically from cerebral blood vessels, corrected for partial volume effects and combined with venous manual samples from 10 min onward (IDIF+VIF). Corrections for plasma/whole-blood ratio and metabolites were done separately with arterial and venous samples. 5-HT(1A) receptor quantification was achieved with arterial input functions (AIF) and IDIF+VIF using a two-tissue compartment model. Comparison between arterial and venous manual blood samples yielded excellent reproducibility. Variability (VAR) was less than 10% for whole-blood activity (p>0.4) and below 2% for plasma to whole-blood ratios (p>0.4). Variability was slightly higher for parent fractions (VARmax=24% at 5 min, p<0.05 and VAR<13% after 20 min, p>0.1) but still within previously reported values. IDIFs after partial volume correction had peak values comparable to AIFs (mean difference Δ=-7.6 ± 16.9 kBq/ml, p>0.1), whereas AIFs exhibited a delay (Δ=4 ± 6.4s, p<0.05) and higher peak width (Δ=15.9 ± 5.2s, p<0.001). Linear regression analysis showed strong agreement for 5-HT(1A) binding as obtained with AIF and IDIF+VIF at baseline (R(2)=0.95), after treatment (R(2)=0.93) and when pooling all scans (R(2)=0.93), with slopes and intercepts in the range of 0.97 to 1.07 and -0.05 to 0.16, respectively. In addition to the region of interest analysis, the approach yielded virtually identical results for voxel-wise quantification as compared to the AIF. Despite the fast metabolism of the radioligand, manual arterial blood samples can be substituted by venous ones for parent fractions and plasma to whole-blood ratios. Moreover, the combination of image-derived and venous input functions provides a reliable quantification of 5-HT(1A) receptors. This holds true for 5-HT(1A) binding estimates before and after treatment for both regions of interest-based and voxel-wise modeling. Taken together, the approach provides less invasive receptor quantification by full independence of arterial cannulation. This offers great potential for the routine use in clinical research protocols and encourages further investigation for other radioligands with different kinetic characteristics. Copyright © 2012 Elsevier Inc. All rights reserved.

  17. The effects of catecholamines and adrenoceptor blocking drugs on the canine peripheral lymph flow.

    PubMed Central

    De Micheli, P; Glässer, A H

    1975-01-01

    Blood flow through the femoral artery, lymph flow in a lymphatic vessel in the femoral triangle and metatarsal distal venous pressure were measured simultaneously in a canine moving hind limb. 2. Low intra-arterial doses of adrenaline and noradrenaline increased lymph flow even in the presence of marked arterial vasoconstriction. In contrast, isoprenaline increased arterial blood flow without affecting lymph flow rate. 3. Phenoxybenzamine, dihydroergotoxine, and nicergoline did not inhibit the lymphatic flow increase induced by adrenaline at doses active on arterial or venous vascular alpha-adrenoceptors. 4. Propranolol given intra-arterially into animals pretreated with alpha-adrenoceptor blocking agents restored the vasoconstrictor effect of adrenaline (reversal of adrenaline reversal). PMID:238702

  18. Venous pump of the calf: a study of venous and muscular pressures.

    PubMed

    Alimi, Y S; Barthelemy, P; Juhan, C

    1994-11-01

    Little data are available concerning the relation between the muscular pumping mechanism and the variation of superficial and deep venous pressure during normal action of the calf pump; therefore we undertook this study to determine the pressure values in three compartments of the calf and in the deep and the superficial venous system and to establish correlation between muscular and venous pressure. Nine healthy young women with a mean age of 23 years (range 19 to 28 years) were examined. In the same calf, a muscular catheter was placed in the deep posterior compartment (DPC), in the superficial posterior compartment (SPC), and in the anterior tibial compartment (ATC), and a vascular catheter was placed in the popliteal vein and in the greater saphenous vein (GSV). The five lines of pressure were simultaneously recorded in the following situations: at rest, during Valsalva maneuver, foot flexion, and foot extension. The situation was studied with the patient in the following positions: decubitus, sitting, standing, and squatting. A final continuous recording was carried out after the patient had been walking for 5 minutes. Mean values with standard errors of muscular and venous pressure were established in each situation. At rest and during Valsalva maneuver, the muscular pressures did not vary, whereas venous pressures increased significantly when the patient was sitting and standing. On the other hand, squatting was associated with a rise in the muscular and vein pressures. Foot flexion entailed a significant increase in the ATC pressure and a rise in the GSV pressure, whereas foot extension caused the DPC pressure to rise without venous pressure modifications. Walking was associated with an alternating increase in the DPC, SPC, GSV and popliteal vein pressures when the foot was compressed to floor followed by a significant decrease when the foot pressure was released. The variations in the deep and superficial venous pressures when the patient is sitting and standing both at rest and during Valsalva maneuver are not associated with an increase in the muscular pressure. On the contrary, during foot movements, the ATC and the DPC are responsible for superficial vein pressure variations without modifications of the SPC pressure.

  19. Malaria PCR Detection in Cambodian Low-Transmission Settings: Dried Blood Spots versus Venous Blood Samples

    PubMed Central

    Canier, Lydie; Khim, Nimol; Kim, Saorin; Eam, Rotha; Khean, Chanra; Loch, Kaknika; Ken, Malen; Pannus, Pieter; Bosman, Philippe; Stassijns, Jorgen; Nackers, Fabienne; Alipon, SweetC; Char, Meng Chuor; Chea, Nguon; Etienne, William; De Smet, Martin; Kindermans, Jean-Marie; Ménard, Didier

    2015-01-01

    In the context of malaria elimination, novel strategies for detecting very low malaria parasite densities in asymptomatic individuals are needed. One of the major limitations of the malaria parasite detection methods is the volume of blood samples being analyzed. The objective of the study was to compare the diagnostic accuracy of a malaria polymerase chain reaction assay, from dried blood spots (DBS, 5 μL) and different volumes of venous blood (50 μL, 200 μL, and 1 mL). The limit of detection of the polymerase chain reaction assay, using calibrated Plasmodium falciparum blood dilutions, showed that venous blood samples (50 μL, 200 μL, 1 mL) combined with Qiagen extraction methods gave a similar threshold of 100 parasites/mL, ∼100-fold lower than 5 μL DBS/Instagene method. On a set of 521 field samples, collected in two different transmission areas in northern Cambodia, no significant difference in the proportion of parasite carriers, regardless of the methods used was found. The 5 μL DBS method missed 27% of the samples detected by the 1 mL venous blood method, but most of the missed parasites carriers were infected by Plasmodium vivax (84%). The remaining missed P. falciparum parasite carriers (N = 3) were only detected in high-transmission areas. PMID:25561570

  20. Comparative Evaluation of Two Venous Sampling Techniques for the Assessment of Pancreatic Insulin and Zinc Release upon Glucose Challenge.

    PubMed

    Pillai, Anil Kumar; Silvers, William; Christensen, Preston; Riegel, Matthew; Adams-Huet, Beverley; Lingvay, Ildiko; Sun, Xiankai; Öz, Orhan K

    2015-01-01

    Advances in noninvasive imaging modalities have provided opportunities to study β cell function through imaging zinc release from insulin secreting β cells. Understanding the temporal secretory pattern of insulin and zinc corelease after a glucose challenge is essential for proper timing of administration of zinc sensing probes. Portal venous sampling is an essential part of pharmacological and nutritional studies in animal models. The purpose of this study was to compare two different percutaneous image-guided techniques: transhepatic ultrasound guided portal vein access and transsplenic fluoroscopy guided splenic vein access for ease of access, safety, and evaluation of temporal kinetics of insulin and zinc release into the venous effluent from the pancreas. Both techniques were safe, reproducible, and easy to perform. The mean time required to obtain desired catheter position for venous sampling was 15 minutes shorter using the transsplenic technique. A clear biphasic insulin release profile was observed in both techniques. Statistically higher insulin concentration but similar zinc release after a glucose challenge was observed from splenic vein samples, as compared to the ones from the portal vein. To our knowledge, this is the first report of percutaneous methods to assess zinc release kinetics from the porcine pancreas.

  1. Comparative Evaluation of Two Venous Sampling Techniques for the Assessment of Pancreatic Insulin and Zinc Release upon Glucose Challenge

    PubMed Central

    Pillai, Anil Kumar; Silvers, William; Christensen, Preston; Riegel, Matthew; Adams-Huet, Beverley; Lingvay, Ildiko; Sun, Xiankai; Öz, Orhan K.

    2015-01-01

    Advances in noninvasive imaging modalities have provided opportunities to study β cell function through imaging zinc release from insulin secreting β cells. Understanding the temporal secretory pattern of insulin and zinc corelease after a glucose challenge is essential for proper timing of administration of zinc sensing probes. Portal venous sampling is an essential part of pharmacological and nutritional studies in animal models. The purpose of this study was to compare two different percutaneous image-guided techniques: transhepatic ultrasound guided portal vein access and transsplenic fluoroscopy guided splenic vein access for ease of access, safety, and evaluation of temporal kinetics of insulin and zinc release into the venous effluent from the pancreas. Both techniques were safe, reproducible, and easy to perform. The mean time required to obtain desired catheter position for venous sampling was 15 minutes shorter using the transsplenic technique. A clear biphasic insulin release profile was observed in both techniques. Statistically higher insulin concentration but similar zinc release after a glucose challenge was observed from splenic vein samples, as compared to the ones from the portal vein. To our knowledge, this is the first report of percutaneous methods to assess zinc release kinetics from the porcine pancreas. PMID:26273676

  2. To mix or not to mix venous blood samples collected in vacuum tubes?

    PubMed

    Parenmark, Anna; Landberg, Eva

    2011-09-08

    There are recommendations to mix venous blood samples by inverting the tubes immediately after venipuncture. Though mixing allows efficient anticoagulation in plasma tubes and fast initiation of coagulation in serum tubes, the effect on laboratory analyses and risk of haemolysis has not been thoroughly evaluated. Venous blood samples were collected by venipuncture in vacuum tubes from 50 patients (10 or 20 patients in each group). Four types of tubes and 18 parameters used in routine clinical chemistry were evaluated. For each patient and tube, three types of mixing strategies were used: instant mixing, no mixing and 5 min of rest followed by mixing. Most analyses did not differ significantly in samples admitted to different mixing strategies. Plasma lactate dehydrogenase and haemolysis index showed a small but significant increase in samples omitted to instant mixing compared to samples without mixing. However, in one out of twenty non-mixed samples, activated partial thromboplastin time was seriously affected. These results indicate that mixing blood samples after venipuncture is not mandatory for all types of tubes. Instant mixing may introduce interference for those analyses susceptible to haemolysis. However, tubes with liquid-based citrate buffer for coagulation testing should be mixed to avoid clotting.

  3. Estimation of blood haemoglobin concentration using the HemoCue during caesarean section: the effect of sampling site.

    PubMed

    Richards, N A; Boyce, H; Yentis, S M

    2010-01-01

    Haemoglobin concentration measured using the HemoCue is accurate for capillary and venous/arterial blood, provided the recommended sampling method is strictly observed. Analysis of blood, particularly of capillary samples, using the HemoCue is useful during caesarean section. The toe might be preferred to the thumb since it is numb during neuraxial anaesthesia, but whether sampling at either site is accurate in this situation, given the cardiovascular effects of anaesthesia and pregnancy, is not known. We aimed to compare haemoglobin values measured in venous and capillary samples (toe and thumb) during caesarean section under neuraxial anaesthesia. Fifty healthy women having caesarean section under spinal or combined spinal-epidural anaesthesia were included. At the end of surgery, the great toe and thumb (non-i.v. fluid side) were lanced as recommended for a HemoCue reading. A venous blood sample (non-i.v. fluid side) was also taken and sent for formal laboratory measurement and tested with the HemoCue. Bland-Altman analysis was applied to the haemoglobin values. Bias (mean difference) and precision +/- 2 SD were respectively 0.2 +/-1.6 for laboratory vs. toe, 0.1 +/-1.8 for laboratory vs. thumb, and 0.2 +/-1.6 laboratory vs. venous. Our results suggest that in terms of accuracy, the two sites are equally suitable for use during caesarean section under neuraxial anaesthesia. Copyright 2009 Elsevier Ltd. All rights reserved.

  4. Study of Umbilical Cord Blood Culture in Diagnosis of Early-onset Sepsis Among Newborns with High-risk Factors.

    PubMed

    Kalathia, Mitul Babubhai; Shingala, Prakash Ashokbhai; Parmar, Parin Niranjanbhai; Parikh, Yogesh Narenedrabhai; Kalathia, Ila Mitulkumar

    2013-10-01

    Blood culture is gold standard for diagnosis of neonatal sepsis. Low sensitivity of blood culture is usually due to small volume of blood sample, intrapartum antibiotics, and antibiotics given to newborn before sampling. We evaluated use of Umbilical cord blood culture (UCBC) in diagnosis of neonatal sepsis as compared to peripheral venous blood culture. This study was done in tertiary care teaching hospital during May-June 2012. A total of 45 newborns with presence of two or more risk factors of sepsis were included. Blood sample from placental end of umbilical cord was collected and cultured. Primary outcome was diagnosis of neonatal sepsis by use of umbilical cord blood sample as compared with venous blood sample. Secondary outcome was to compare organisms identified by UCBC and venous blood culture. Sensitivity, specificity, positive and negative predictive values of UCBC were calculated. A total of 24.44% (11 out of 45) high-risk newborns had positive UCBC. A total of 17.8% (8 out of 45) newborns had positive blood culture report. Organisms grown in UCBC were Pseudomonas (45%, 5 out of 11), Acinetobacter (27.27%, 3 out of 11), Escherichia coli (18.18%, 2 out of 11), and Klebsiella (9%, 1 out of 11). UCBC is a good method for diagnosis of neonatal sepsis among high-risk newborns as compared to venous blood culture with a sensitivity of 80% and specificity of 91.43%. Organisms grown are comparable to blood culture samples.

  5. Venipuncture versus peripheral catheter: do infusions alter laboratory results?

    PubMed

    Hambleton, Victoria Lerma; Gómez, Ignacio Arribas; Andreu, Francisco A Bernabeu

    2014-01-01

    Our aim was to evaluate the equivalence between analytic parameters from blood samples obtained from a saline solution lock device used for the infusion of drugs and those from venipuncture. In our emergency department, patients bearing a saline solution lock device have blood extracted by venipuncture to avoid possible contamination of the sample. Adults from the emergency department with a saline solution lock device who required laboratory tests were selected as candidates for this cross-sectional observational study. Infusions were halted and flushed with 0.9% saline solution; 2 minutes later, 2 mL of blood was drawn and discarded, and the corresponding laboratory tubes were filled. Immediately after, another sample was withdrawn from the opposite extremity by venipuncture. Both samples were analyzed for hematology, biochemistry, venous blood gases, and coagulation parameters. Concordance was evaluated by use of the intraclass correlation coefficient with its 95% confidence intervals; Bland-Altman plots were used to illustrate the percentage of samples with differences exceeding 2 SDs. The mean differences were also checked to detect those exceeding the laboratory's systematic error. An intraclass correlation coefficient of over 0.9 was achieved for all parameters except for pH, partial pressure of carbon dioxide, and partial pressure of oxygen. Differences of over 2 SDs were found in fewer than 10% of all parameters. None of them exceeded 3 SDs, except for pH and venous blood gases. All parameters showed differences below the laboratory's accepted systematic error except for pH and venous blood gases. Blood samples extracted from a peripheral catheter with or without drug infusions are valid for the analysis of hematology, biochemistry, and coagulation parameters but not for venous blood gases. Nurses should know the benefits of using an existing peripheral catheter for drawing blood samples for laboratory analysis even when infusing commonly used drugs. Emergency nurses should consider collecting blood specimens from a venous access device regardless of the type of drug infusions administered, because it is a safe, simple, and fast technique, which is time efficient when treating patients with limited venous access sites. This procedure reduces patient discomfort and the risk of complications related to venipunctures. Copyright © 2014 Emergency Nurses Association. Published by Mosby, Inc. All rights reserved.

  6. Endovascular stent-based revascularization of malignant superior vena cava syndrome with concomitant implantation of a port device using a dual venous approach.

    PubMed

    Anton, Susanne; Oechtering, T; Stahlberg, E; Jacob, F; Kleemann, M; Barkhausen, J; Goltz, J P

    2018-06-01

    The aim of this paper is to evaluate the safety and efficacy of endovascular revascularization of malignant superior vena cava syndrome (SVCS) and simultaneous implantation of a totally implantable venous access port (TIVAP) using a dual venous approach. Retrospectively, 31 patients (mean age 67 ± 8 years) with malignant CVO who had undergone revascularization by implantation of a self-expanding stent into the superior vena cava (SVC) (Sinus XL®, OptiMed, Germany; n = 11 [Group1] and Protégé ™ EverFlex, Covidien, Ireland; n = 20 [Group 2]) via a transfemoral access were identified. Simultaneously, percutaneous access via a subclavian vein was used to (a) probe the lesion from above, (b) facilitate a through-and-through maneuver, and (c) implant a TIVAP. Primary endpoints with regard to the SVC syndrome were technical (residual stenosis < 30%) and clinical (relief of symptoms) success; with regard to TIVAP implantation technical success was defined as positioning of the functional catheter within the SVC. Secondary endpoints were complications as well as stent and TIVAP patency. Technical and clinical success rate were 100% for revascularization of the SVS and 100% for implantation of the TIVAP. One access site hematoma (minor complication, day 2) and one port-catheter-associated sepsis (major complication, day 18) were identified. Mean catheter days were 313 ± 370 days. Mean imaging follow-up was 184 ± 172 days. Estimated patency rates at 3, 6, and 12 months were 100% in Group 1 and 84, 84, and 56% in Group 2 (p = 0.338). Stent-based revascularization of malignant SVCS with concomitant implantation of a port device using a dual venous approach appears to be safe and effective.

  7. Exploration of attenuated total reflectance mid-infrared spectroscopy and multivariate calibration to measure immunoglobulin G in human sera.

    PubMed

    Hou, Siyuan; Riley, Christopher B; Mitchell, Cynthia A; Shaw, R Anthony; Bryanton, Janet; Bigsby, Kathryn; McClure, J Trenton

    2015-09-01

    Immunoglobulin G (IgG) is crucial for the protection of the host from invasive pathogens. Due to its importance for human health, tools that enable the monitoring of IgG levels are highly desired. Consequently there is a need for methods to determine the IgG concentration that are simple, rapid, and inexpensive. This work explored the potential of attenuated total reflectance (ATR) infrared spectroscopy as a method to determine IgG concentrations in human serum samples. Venous blood samples were collected from adults and children, and from the umbilical cord of newborns. The serum was harvested and tested using ATR infrared spectroscopy. Partial least squares (PLS) regression provided the basis to develop the new analytical methods. Three PLS calibrations were determined: one for the combined set of the venous and umbilical cord serum samples, the second for only the umbilical cord samples, and the third for only the venous samples. The number of PLS factors was chosen by critical evaluation of Monte Carlo-based cross validation results. The predictive performance for each PLS calibration was evaluated using the Pearson correlation coefficient, scatter plot and Bland-Altman plot, and percent deviations for independent prediction sets. The repeatability was evaluated by standard deviation and relative standard deviation. The results showed that ATR infrared spectroscopy is potentially a simple, quick, and inexpensive method to measure IgG concentrations in human serum samples. The results also showed that it is possible to build a united calibration curve for the umbilical cord and the venous samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Mixing problems in using indicators for measuring regional blood flow

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ushioda, E.; Nuwayhid, B.; Tabsh, K.

    A basic requirement for using indicators for measuring blood flow is adequate mixing of the indicator with blood prior to sampling the site. This requirement has been met by depositing the indicator in the heart and sampling from an artery. Recently, authors have injected microspheres into veins and sampled from venous sites. The present studies were designed to investigate the mixing problems in sheep and rabbits by means of Cardio-Green and labeled microspheres. The indicators were injected at different points in the circulatory system, and blood was sampled at different levels of the venous and arterial systems. Results show themore » following: (a) When an indicator of small molecular size (Cardio-Green) is allowed to pass through the heart chambers, adequate mixing is achieved, yielding accurate and reproducible results. (b) When any indicator (Cardio-Green or microspheres) is injected into veins, and sampling is done at any point in the venous system, mixing is inadequate, yielding flow results which are inconsistent and erratic. (c) For an indicator or large molecular size (microspheres), injecting into the left side of the heart and sampling from arterial sites yield accurate and reproducible results regardless of whether blood is sampled continuously or intermittently.« less

  9. Comparison of digoxin concentration in plastic serum tubes with clot activator and heparinized plasma tubes.

    PubMed

    Dukić, Lora; Simundić, Ana-Maria; Malogorski, Davorin

    2014-01-01

    Sample type recommended by the manufacturer for the digoxin Abbott assay is either serum collected in glass tubes or plasma (sodium heparin, lithium heparin, citrate, EDTA or oxalate as anticoagulant) collected in plastic tubes. In our hospital samples are collected in plastic tubes. Our hypothesis was that the serum sample collected in plastic serum tube can be used interchangeably with plasma sample for measurement of digoxin concentration. Our aim was verification of plastic serum tubes for determination of digoxin concentration. Concentration of digoxin was determined simultaneously in 26 venous blood plasma (plastic Vacuette, LH Lithium heparin) and serum (plastic Vacuette, Z Serum Clot activator; both Greiner Bio-One GmbH, Kremsmünster, Austria) samples, on Abbott AxSYM analyzer using the original Abbott Digoxin III assay (Abbott, Wiesbaden, Germany). Tube comparability was assessed using the Passing Bablok regression and Bland-Altman plot. Serum and plasma digoxin concentrations are comparable. Passing Bablok intercept (0.08 [95% CI = -0.10 to 0.20]) and slope (0.99 [95% CI = 0.92 to 1.11]) showed there is no constant or proportional error. Blood samples drawn in plastic serum tubes and plastic plasma tubes can be interchangeably used for determination of digoxin concentration.

  10. Comparison of digoxin concentration in plastic serum tubes with clot activator and heparinized plasma tubes

    PubMed Central

    Dukić, Lora; Šimundić, Ana-Maria; Malogorski, Davorin

    2014-01-01

    Introduction: Sample type recommended by the manufacturer for the digoxin Abbott assay is either serum collected in glass tubes or plasma (sodium heparin, lithium heparin, citrate, EDTA or oxalate as anticoagulant) collected in plastic tubes. In our hospital samples are collected in plastic tubes. Our hypothesis was that the serum sample collected in plastic serum tube can be used interchangeably with plasma sample for measurement of digoxin concentration. Our aim was verification of plastic serum tubes for determination of digoxin concentration. Materials and methods: Concentration of digoxin was determined simultaneously in 26 venous blood plasma (plastic Vacuette, LH Lithium heparin) and serum (plastic Vacuette, Z Serum Clot activator; both Greiner Bio-One GmbH, Kremsmünster, Austria) samples, on Abbott AxSYM analyzer using the original Abbott Digoxin III assay (Abbott, Wiesbaden, Germany). Tube comparability was assessed using the Passing Bablok regression and Bland-Altman plot. Results: Serum and plasma digoxin concentrations are comparable. Passing Bablok intercept (0.08 [95% CI = −0.10 to 0.20]) and slope (0.99 [95% CI = 0.92 to 1.11]) showed there is no constant or proportional error. Conclusion: Blood samples drawn in plastic serum tubes and plastic plasma tubes can be interchangeably used for determination of digoxin concentration. PMID:24627723

  11. The gaseous messenger carbon monoxide is released from the eye into the ophthalmic venous blood depending on the intensity of sunlight.

    PubMed

    Koziorowski, M; Stefańczyk-Krzymowska, S; Tabecka-Lonczyńska, A; Gilun, P; Kamiński, M

    2012-01-01

    Circadian and seasonal rhythms in daylight affect many physiological processes. In the eye, energy of intense visible light not only initiates a well-studied neural reaction in the retina that modulates the secretory function of the hypothalamus and pineal gland, but also activates the heme oxygenase (HO) to produce carbon monoxide (CO). This study was designed to determine whether the concentration of carbon monoxide (CO) in the ophthalmic venous blood changes depending on the phase of the day and differing extremely light intensity seasons: summer and winter. The concentration of CO in the venous blood flowing out from the nasal cavity, where heme oxygenase (HO) is expressed, but no photoreceptors, was used as a control. Sixteen mature males of a wild boar and pig crossbreed were used for this study. Samples of ophthalmic and nasal venous blood and systemic arterial and venous blood were collected repeatedly for two consecutive days during the longest days of the summer and the shortest days of the winter. The concentrations of CO in blood samples was measured using a standard addition method. During the longest days of the summer the concentration of CO in ophthalmic venous blood averaged 3.32 ± 0.71 and 3.43 ± 0.8 nmol/ml in the morning and afternoon, respectively, and was significantly higher than in the night averaging 0.89 ± 0.12 nmol/ml (p<0.001). During the shortest day of the winter CO concentration in ophthalmic venous blood was 1.11 ± 0.10 and 1.13 ± 0.14 nmol/ml during the light and nocturnal phase, respectively, and did not differ between phases, but was lower than in the light phase of the summer (p<0.01). The CO concentration in the control nasal venous blood did not differ between seasons and day phases and was lower than in ophthalmic venous blood during the summer (p<0.01) and winter (p<0.05). The results indicate that the gaseous messenger carbon monoxide is released from the eye into the ophthalmic venous blood depending on the intensity of sunlight.

  12. Qualitative Slow Blood Flow in Lower Extremity Deep Veins on Doppler Sonography: Quantitative Assessment and Preliminary Evaluation of Correlation With Subsequent Deep Venous Thrombosis Development in a Tertiary Care Oncology Center.

    PubMed

    Jensen, Corey T; Chahin, Antoun; Amin, Veral D; Khalaf, Ahmed M; Elsayes, Khaled M; Wagner-Bartak, Nicolaus; Zhao, Bo; Zhou, Shouhao; Bedi, Deepak G

    2017-09-01

    To determine whether the qualitative sonographic appearance of slow deep venous flow in the lower extremities correlates with quantitative slow flow and an increased risk of deep venous thrombosis (DVT) in oncology patients. In this Institutional Review Board-approved retrospective study, we reviewed lower extremity venous Doppler sonographic examinations of 975 consecutive patients: 482 with slow flow and 493 with normal flow. The subjective slow venous flow and absence of initial DVT were confirmed by 2 radiologists. Peak velocities were recorded at 3 levels. Each patient was followed for DVT development. The associations between DVT and the presence of slow venous flow were examined by the Fisher exact test; a 2-sample t test was used for peak velocity and DVT group comparisons. The optimal cutoff peak velocity for correlation with the radiologists' perceived slow flow was determined by the Youden index. Deep venous thrombosis development in the slow-flow group (21 of 482 [4.36%]) was almost doubled compared with patients who had normal flow (11 of 493 [2.23%]; P = .0456). Measured peak venous velocities were lower in the slow-venous flow group (P < .001). Patients with subsequent DVT did not have a significant difference in venous velocities compared with their respective patient groups. The sum of 3 venous level velocities resulted in the best cutoff for dichotomizing groups into normal versus slow venous flow. Qualitative slow venous flow in the lower extremities on Doppler sonography accurately correlates with quantitatively slower flow, and this preliminary evaluation suggests an associated mildly increased rate of subsequent DVT development in oncology patients. © 2017 by the American Institute of Ultrasound in Medicine.

  13. The accuracy of a near-infrared spectroscopy cerebral oximetry device and its potential value for estimating jugular venous oxygen saturation.

    PubMed

    Ikeda, Keita; MacLeod, David B; Grocott, Hilary P; Moretti, Eugene W; Ames, Warwick; Vacchiano, Charles

    2014-12-01

    An intriguing potential clinical use of cerebral oximeter measurements (SctO2) is the ability to noninvasively estimate jugular bulb venous oxygen saturation (SjvO2). Our purpose in this study was to determine the accuracy of the FORE-SIGHT(®) (CAS Medical Systems, Branford, CT), which is calibrated to a weighted average of 70% (SjvO2) and 30% arterial saturation, for Food and Drug Administration pre-market approval 510(k) certification by adapting an industry standard protocol, ISO 9919:2005 (www.ISO.org) (used for pulse oximeters), and to evaluate the use of SctO2 and SpO2 measurements to noninvasively estimate jugular venous oxygen saturation (SnvO2). Paired blood gas samples from the radial artery and the jugular venous bulb were collected from 20 healthy volunteers undergoing progressive oxygen desaturation from 100% to 70%. The blood sample pairs were analyzed via co-oximetry and used to calculate the approximate mixed vascular cerebral blood oxygen saturation, or reference SctO2 values (refSctO2), during increasing hypoxia. These reference values were compared to bilateral FORE-SIGHT SctO2 values recorded simultaneously with the blood gas draws to determine its accuracy. Bilateral SctO2 and SpO2 measurements were then used to calculate SnvO2 values which were compared to SjvO2. Two hundred forty-six arterial and 253 venous samples from 18 subjects were used in the analysis. The ipsilateral FORE-SIGHT SctO2 values showed a tolerance interval (TI) of [-10.72 to 10.90] and Lin concordance correlation coefficient (CCC) with standard error (SE) of 0.83 ± 0.073 with the refSctO2 values calculated using arterial and venous blood gases. The ipsilateral data had a CCC of 0.81 + 0.059 with TI of [-9.22 to 9.40] with overall bias of 0.09%, and amplitude of the root mean square of error after it was corrected with random effects analysis was 2.92%. The bias and variability values between the ipsilateral and the contralateral FORE-SIGHT SctO2 measurements varied from person to person. The SnvO2 calculated from the ipsilateral SctO2 and SpO2 data showed a CCC ± SE of 0.79 ± 0.088, TI = [-14.93 to 15.33], slope of 0.98, y-intercept of 1.14% with SjvO2 values with a bias of 0.20% and an Arms of 4.08%. The SnvO2 values calculated independently from contralateral forehead FORE-SIGHT SctO2 values were not as correlated with the SjvO2 values (contralateral side CCC + SE = 0.72 ± 0.118, TI = [-14.86 to 15.20], slope of 0.66, and y-intercept of 20.36%). The FORE-SIGHT cerebral oximeter was able to estimate oxygen saturation within the tissues of the frontal lobe under conditions of normocapnia and varying degrees of hypoxia (with 95% confidence interval of [-5.60 to 5.78] with ipsilateral blood sample data). These findings from healthy volunteers also suggest that the use of the calculated SnvO2 derived from SctO2 and SpO2 values may be a reasonable noninvasive method of estimating SjvO2 and therefore global cerebral oxygen consumption in the clinical setting. Further laboratory and clinical research is required to define the clinical utility of near-infrared spectroscopy determination of SctO2 and SnvO2 in the operating room setting.

  14. Correlation of Peripheral Vein Tumour Marker Levels, Internal Iliac Vein Tumour Marker Levels and Radical Prostatectomy Specimens in Patients with Prostate Cancer and Borderline High Prostate-Specific Antigen: A Pilot Study.

    PubMed

    Farrelly, Cormac; Lal, Priti; Trerotola, Scott O; Nadolski, Gregory J; Watts, Micah M; Gorrian, Catherine Mc; Guzzo, Thomas J

    2016-05-01

    To correlate prostate-specific antigen (PSA), free to total PSA percentage (fPSA%) and prostatic acid phosphatase (PAP) levels from peripheral and pelvic venous samples with prostatectomy specimens in patients with prostate adenocarcinoma and borderline elevation of PSA. In this prospective institutional review board approved study, 7 patients with biopsy proven prostate cancer had a venous sampling procedure prior to prostatectomy (mean 3.2 days, range 1-7). Venous samples were taken from a peripheral vein (PVS), the right internal iliac vein, a deep right internal iliac vein branch, left internal iliac vein and a deep left internal iliac vein branch. Venous sampling results were compared to tumour volume, laterality, stage and grade in prostatectomy surgical specimens. Mean PVS PSA was 4.29, range 2.3-6 ng/ml. PSA and PAP values in PVS did not differ significantly from internal iliac or deep internal iliac vein samples (p > 0.05). fPSA% was significantly higher in internal iliac (p = 0.004) and deep internal iliac (p = 0.003) vein samples compared to PVS. One of 7 patients had unilateral tumour only. This patient, with left-sided tumour, had a fPSA% of 6, 6, 6, 14 and 12 in his peripheral, right internal iliac, deep right internal iliac branch, left internal iliac and deep left internal iliac branch samples respectively. There were no adverse events. fPSA%, unlike total PSA or PAP, is significantly higher in pelvic vein compared to peripheral vein samples when prostate cancer is present. Larger studies including patients with higher PSA values are warranted to further investigate this counterintuitive finding.

  15. [Superficial venous thrombosis. A state of art].

    PubMed

    Sándor, Tamás

    2017-01-01

    For a long time superficial thrombophlebitis has been thought to be a rather benign condition. Recently, when duplex ultrasound technique is used for the diagnosis more and more often, the disease is proved to be more dangerous than anticipated. Thrombosis propagates to the deep veins in 6-44% and pulmonary embolism was observed on the patients in 1,5-33%. We can calculate venous thromboembolic complications on every fourth patient. Diagnosis is clinical, but duplex ultrasound examination is mandatory, for estimation of the thrombus extent, for exclusion of the deep venous thrombosis and for follow up. Both legs should be checked with ultrasound, because simultaneous deep venous thrombosis can develop on the contralateral limb. Two different forms can be distinguished: superficial venous thrombosis with, or without varicose veins. In cases of spontaneous, non varicous form, especially when the process is migrating or recurrent, a careful clinical examination is necessery for exclusion of malignant diseases and thrombophilia. The treatment options are summarised on the basis of recent international consensus statements. The American and German guidelines are similar. Compression and mobilisation are cornerstones of the therapy. For a short segment thrombosis non steroidal antiinflammatory drugs are effective. For longer segments low molecular-weight heparins are preferred. Information on the effect of the novel oral anticoagulants for the therapy is lacking but they may appear to be effective in the future for this indication. When thrombus is close to the sapheno-femoral or sapheno-popliteal junction crossectomy (high ligation), or low molecular-weight heparin in therapeutic doses are indicated. The term superficial thrombophlebitis should be discouraged, because inflammation and infection is not the primary pathology. It should be called correctly superficial venous thrombosis in order to avoid the unnecessary administration of antibiotics and the misconception, that superficial venous thrombosis is benign disease. Orv. Hetil., 2017, 158(4), 129-138.

  16. Estrogen Receptors and Chronic Venous Disease.

    PubMed

    Serra, R; Gallelli, L; Perri, P; De Francesco, E M; Rigiracciolo, D C; Mastroroberto, P; Maggiolini, M; de Franciscis, S

    2016-07-01

    Chronic venous disease (CVD) is a common and relevant problem affecting Western people. The role of estrogens and their receptors in the venous wall seems to support the major prevalence of CVD in women. The effects of the estrogens are mediated by three estrogen receptors (ERs): ERα, ERβ, and G protein-coupled ER (GPER). The expression of ERs in the vessel walls of varicose veins is evaluated. In this prospective study, patients of both sexes, with CVD and varicose veins undergoing open venous surgery procedures, were enrolled in order to obtain vein samples. To obtain control samples of healthy veins, patients of both sexes without CVD undergoing coronary artery bypass grafting with autologous saphenous vein were recruited (control group). Samples were processed in order to evaluate gene expression. Forty patients with CVD (10 men [25%], 30 women [75%], mean age 54.3 years [median 52 years, range 33-74 years]) were enrolled. Five patients without CVD (three men, two women [aged 61-73 years]) were enrolled as the control group. A significant increase of tissue expression of ERα, ERβ and GPER in patients with CVD was recorded (p < .01), which was also related to the severity of venous disease. ERs seem to play a role in CVD; in this study, the expression of ERs correlated with the severity of the disease, and their expression was correlated with the clinical stage. Copyright © 2016 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  17. Order of draw practices in venous blood sampling at clinical biochemistry departments in the Danish health care system.

    PubMed

    Jacobsen, Katja Kemp; Brandt, Ida; Christensen, Anne Vindahl; Rimsø, Bjørk Anine; Krøier, Camilla Julie; Sørensen, Michelle; Smith, Julie; Jensen, Kathrine Overgaard Foss; Larsen, Jeppe Madura

    2018-06-01

    Deviation in blood collection procedures is a central source of preanalytical variation affecting overall analytical and diagnostic precision. The order of draw of venous sampling is suspected to affect analytical results, in particular for coagulation analysis. Here we compare the procedures in venous blood sampling among clinical biochemistry departments to assess the uniformity of order of blood draw and adherence to international guidelines in the Danish health care system. We collected venous order of draw procedures from 49 clinical biochemistry departments at 22 public hospitals in Denmark. Procedures were compared to the international guidelines fromthe Clinical Laboratory Standards Institute (CLSI) and World Health Organization (WHO), and assessed in relation to department ISO 15189:2012 accreditation. We observed seven different order of draw procedures related to citrate, serum, heparin, and EDTA tubes, and the use of discard tubes in relation to coagulation assays. 31 departments (63.3%) were found to adhere to CLSI and WHO guidelines. A majority of departments instructs the use of discard tubes before collection for coagulation assays in citrate tubes (44 departments; 89.8%). The citrate tube was the first sample tube to be drawn for most departments (35 departments; 75.5%); and the preferred order of non-citrate tubes was serum-heparin-EDTA (36 departments; 73.5%). Adherence to the CLSI and WHO guidelines was not associated with department ISO 15189:2012 accreditation (p = .57). Venous order of draw procedures is diverse at Danish clinical biochemistry departments and show moderate adherence to international guidelines. Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  18. Structural locus of transmucosal albumin efflux in canine ileum. A fluorescent study.

    PubMed

    Granger, D N; Cook, B H; Taylor, A E

    1976-12-01

    This study demonstrates the effects of elevated intestinal venous pressure on the intestinal tissue spaces and the histological locus of the transmucosal albumin flux under such conditions. The authors were able to localize albumin in the tissues using an Evans blue-albumin fluorescence technique. This technique makes use of the fluorescence properties and albumin affinity of Evans blue dye (T-1824). Evans blue dye has a high affinity for albumin and emits a red-orange fluorescence at a wavelength of 720 nm. Evans blue was mixed with a solution of bovine serum albumin at concentrations that yield negligible amounts of free dye. Control ileal samples were obtained in order to visualize the natural tissue morphology and fluorescence. The Evans blue-albumin solution was injected and tissue samples were obtained 15 and 60 min postinjection, then venous outflow was occluded and after 15 and 60 min the tissues were sampled. Each sample was immediately frozen, freeze dried, embedded in paraffin, and 7-mu sections were made. The Evans blue-albumin was demonstrated histologically with a fluorescence microscope. No leakage sites were apparent at normal venous pressures. However, after elevation of venous pressure, Evans blue-albumin was observed in the interepithelial and/or intraepithelial spaces of villus tips, but no Evans blue-albumin was observed either between or within the epithelial cells of the crypts, or within the tubular crypt lumina. These results indicate that at elevated venous pressures, the transmucosal albumin flux occurs exclusively at the villus tip region, suggesting a great vulnerability of the cells found in this region to elevations in tissue pressure as compared to the crypt epithelial cells.

  19. Detection of Trypanosoma cruzi in untreated chronic chagasic patients is improved by using three parasitological methods simultaneously.

    PubMed

    Zulantay, Inés; Apt, Werner; Valencia, Claudio; Torres, Alberto; Saavedra, Miguel; Rodríguez, Jorge; Sandoval, Lea; Martínez, Gabriela; Thieme, Patricio; Sepúlveda, Eduardo

    2011-10-01

    This study compared three parasitological methods applied simultaneously in individuals with untreated chronic Chagas' disease in order to determine their individual and combined performances. From a total of 100 chronic chagasic patients from endemic areas of Chile, with informed consent, we extracted 2 mL of peripheral venous blood for PCR (PCR-B) and applied two xenodiagnosis (XD) boxes with seven uninfected Triatoma infestans nymphs each for microscopic examination and PCR of faecal samples of the triatomines fed on each patient (PCR-XD). The PCR-B and PCR-XD reactions were performed with oligonucleotides 121 and 122, which anneal to the four constant regions of the minicircles of Trypanosoma cruzi kinetoplasts. The 330 bp PCR product was analysed by electrophoresis in a 2% agarose gel and visualized by staining with ethidium bromide. PCR-B detected T. cruzi in 58% of the cases, while PCR-XD proved to be more sensitive than XD (67% versus 14%, respectively) (P = 0.0001). There was no difference between the detection power of PCR-B and PCR-XD (P = 0.222). The percentage detected as positive was much greater when the three tests were considered (84%) (P = 0.00001). The simultaneous application of more than one technique for the parasitological diagnosis of Chagas' disease in untreated individuals increases the possibility of detection of T. cruzi.

  20. Influence of protein ingestion on human splanchnic and whole-body oxygen consumption, blood flow, and blood temperature.

    PubMed

    Brundin, T; Wahren, J

    1994-05-01

    Splanchnic and whole-body oxygen uptake, blood flow, and blood temperature were studied in 10 healthy subjects before and during 2 hours after oral ingestion of 900 kJ of fish protein. Indirect calorimetry and catheter techniques were used, including blood thermometry in arterial, pulmonary arterial, and hepatic venous blood. After the meal, pulmonary oxygen uptake increased from a basal value of 272 +/- 11 to 332 +/- 23 mL/min. During the first postprandial hour, splanchnic oxygen uptake increased from 62 +/- 5 to 93 +/- 9 mL/min (+50%, P < .05), thereby accounting for 62% +/- 17% of the simultaneous increase in whole-body oxygen consumption. During the second postprandial hour, splanchnic oxygen uptake increased no further, whereas in the extrasplanchnic tissues the oxygen consumption increased, now accounting for the entire simultaneous increase in pulmonary oxygen uptake. Cardiac output increased from basal 6.4 +/- 0.4 to 7.5 +/- 0.5 L/min. Splanchnic blood flow changed little while the arteriohepatic venous oxygen difference increased from 46 +/- 3 to 54 +/- 4 mL/L. Arterial and hepatic venous blood temperatures increased by almost 0.3 degrees C, reflecting a considerable accumulation of heat, indicating a conversion into a positive thermal balance. It is concluded that after protein ingestion, (1) oxygen uptake increases mainly in the splanchnic organs during the first hour, and thereafter exclusively in the extrasplanchnic tissues; (2) the blood flow increases mainly in extrasplanchnic tissues; and (3) the blood temperature increases almost linearly, indicating an upward adjustment of the temperature setpoint in the central thermosensors.

  1. Anatomical Variations of the Right Adrenal Vein: Concordance Between Multidetector Computed Tomography and Catheter Venography.

    PubMed

    Omura, Kensuke; Ota, Hideki; Takahashi, Yuuki; Matsuura, Tomonori; Seiji, Kazumasa; Arai, Yoichi; Morimoto, Ryo; Satoh, Fumitoshi; Takase, Kei

    2017-03-01

    Adrenal venous sampling is the most reliable diagnostic procedure to determine surgical indications in primary aldosteronism. Because guidelines recommend multidetector computed tomography (CT) to evaluate the adrenal gland, some past reports used multidetector CT as a guide for adrenal venous sampling. However, the detailed anatomy of the right adrenal vein and its relationship with an accessory hepatic vein remains uncertain. The purpose of this study was to describe detailed anatomical variations of the right adrenal vein and to determine the concordance between CT and catheter venography in patients with primary aldosteronism. In total, 440 consecutive patients who underwent adrenal venous sampling were included. Four-phase dynamic CT was performed. Anatomical locations and variations of the right adrenal vein and its relationship with the accessory hepatic vein were compared with catheter venographic findings. Successful catheterization was achieved in 437 patients (99%). The right adrenal vein was visualized in the late arterial phase with CT in 420 patients (95%). The right adrenal vein formed a common trunk with the accessory hepatic vein in 87 patients (20%). CT identified the correct craniocaudal level of the orifice in 354 patients (84%). Anatomical variations, location, and angle of inflow of the right adrenal vein based on CT demonstrated high concordance with catheter venography. CT may provide useful information for preparation before adrenal venous sampling. © 2017 American Heart Association, Inc.

  2. Capillary blood sampling as an alternative to venipuncture in the assessment of serum 25 hydroxyvitamin D levels.

    PubMed

    Dayre McNally, J; Matheson, Loren A; Sankaran, Koravangattu; Rosenberg, Alan M

    2008-11-01

    This study compared 25-hydroxyvitamin D [25(OH)D] measurements in capillary and venous blood samples collected, respectively by fingerprick and venipuncture. Capillary blood for measuring 25(OH)D has potential advantages by reducing blood volume required (2mL versus 0.3mL for venipuncture and capillary sampling, respectively), facilitating blood collection for those populations in whom venipuncture is difficult (e.g. infants and children), improving patient convenience and reducing costs associated with phlebotomy. The results demonstrated a highly significant relationship between 25(OH)D levels in serum derived from venous and capillary blood samples (r(2)=0.901). Despite statistically higher 25(OH)D levels in fingerprick samples (108+/-9nmol/L) compared with venipuncture samples (90+/-7nmol/L), the correlation between venous and capillary samples provides support for this approach as a practical alternative to venipuncture for vitamin D determination. However, clinical application may require the incorporation of a correction factor for the assessment of insufficiency, and research studies should avoid using the two methods interchangeably. Studying vitamin D's role in health and disease requires collection techniques and measurement methods that are reliable, reproducible, easily accessible, inexpensive and minimally burdensome to the patient. The option to collect patient samples by fingerprick may facilitate the collection process.

  3. Endogenous pro-thrombotic biomarkers from the arm and leg may not have the same value.

    PubMed

    Lattimer, Christopher R; Kalodiki, Evi; Geroulakos, George; Hoppensteadt, Debra; Fareed, Jawed

    2016-05-01

    Assessments of endogenous pro-thrombotic biomarkers are performed invariably on arm blood. However, the commonest site for thrombosis is in the leg. A leg blood sample may reflect local pro-thrombotic processes more accurately than systemic arm blood. The aim was to determine whether pro-thrombotic biomarkers from standard venous arm samples differed significantly from leg samples. Concurrent blood samples were taken from an ankle/lower calf varicose vein and an ante-cubital vein in 24 patients awaiting laser treatment as well as age approximated and sex matched healthy controls without venous disease. The following assays were performed: thrombin-antithrombin (ng/ml), antithrombin (%) activity, microparticles (nM), fibrinogen (mg/dl), prothrombin fragment 1.2 (F1.2) (pM) and P-selectin (ng/ml). Expressed as median (inter-quartile range). Significant arm/leg differences were observed in thrombin-antithrombin, antithrombin, prothrombin fragment 1.2 and P-selectin. The legs of patients had significantly reduced antithrombin activity and P-selectin concentrations compared to their arms (leg: 101 (90-108) versus arm: 112 (99-126), P = 0.001 and leg: 42 (26-52) versus 45 (27-52), P = 0.044, respectively). Control leg samples had significantly increased thrombin-antithrombin and P-selectin compared to control arm samples (leg: 2.1 (0.9-3.2) versus arm: 0.8 (0.5-1.7), P = 0.015 and leg: 36 (24-50) versus arm: 30 (23-41), P = 0.007, respectively). However, the control legs had significantly reduced F1.2 (leg: 265 (230-333) versus arm: 299 (236-361), P = 0.028). No significant arm/leg differences were detected in the microparticle or fibrinogen levels. These findings indicate that venous arm blood is significantly different from venous leg blood in four out of six biomarkers studied. Recognition of local venous leg sampling as a site for investigation may unravel why the leg has a greater predisposition to thrombosis and lead the way towards an arm/leg differential test. © The Author(s) 2015.

  4. HIV-1 viral load measurement in venous blood and fingerprick blood using Abbott RealTime HIV-1 DBS assay.

    PubMed

    Tang, Ning; Pahalawatta, Vihanga; Frank, Andrea; Bagley, Zowie; Viana, Raquel; Lampinen, John; Leckie, Gregor; Huang, Shihai; Abravaya, Klara; Wallis, Carole L

    2017-07-01

    HIV RNA suppression is a key indicator for monitoring success of antiretroviral therapy. From a logistical perspective, viral load (VL) testing using Dried Blood Spots (DBS) is a promising alternative to plasma based VL testing in resource-limited settings. To evaluate the analytical and clinical performance of the Abbott RealTime HIV-1 assay using a fully automated one-spot DBS sample protocol. Limit of detection (LOD), linearity, lower limit of quantitation (LLQ), upper limit of quantitation (ULQ), and precision were determined using serial dilutions of HIV-1 Virology Quality Assurance stock (VQA Rush University), or HIV-1-containing armored RNA, made in venous blood. To evaluate correlation, bias, and agreement, 497 HIV-1 positive adult clinical samples were collected from Ivory Coast, Uganda and South Africa. For each HIV-1 participant, DBS-fingerprick, DBS-venous and plasma sample results were compared. Correlation and bias values were obtained. The sensitivity and specificity were analyzed at a threshold of 1000 HIV-1 copies/mL generated using the standard plasma protocol. The Abbott HIV-1 DBS protocol had an LOD of 839 copies/mL, a linear range from 500 to 1×10 7 copies/mL, an LLQ of 839 copies/mL, a ULQ of 1×10 7 copies/mL, and an inter-assay SD of ≤0.30 log copies/mL for all tested levels within this range. With clinical samples, the correlation coefficient (r value) was 0.896 between DBS-fingerprick and plasma and 0.901 between DBS-venous and plasma, and the bias was -0.07 log copies/mL between DBS-fingerprick and plasma and -0.02 log copies/mL between DBS-venous and plasma. The sensitivity of DBS-fingerprick and DBS-venous was 93%, while the specificity of both DBS methods was 95%. The results demonstrated that the Abbott RealTime HIV-1 assay with DBS sample protocol is highly sensitive, specific and precise across a wide dynamic range and correlates well with plasma values. The Abbott RealTime HIV-1 assay with DBS sample protocol provides an alternative sample collection and transfer option in resource-limited settings and expands the utility of a viral load test to monitor HIV-1 ART treatment for infected patients. Copyright © 2017 The Author(s). Published by Elsevier B.V. All rights reserved.

  5. Diagnostic accuracy of serological diagnosis of hepatitis C and B using dried blood spot samples (DBS): two systematic reviews and meta-analyses.

    PubMed

    Lange, Berit; Cohn, Jennifer; Roberts, Teri; Camp, Johannes; Chauffour, Jeanne; Gummadi, Nina; Ishizaki, Azumi; Nagarathnam, Anupriya; Tuaillon, Edouard; van de Perre, Philippe; Pichler, Christine; Easterbrook, Philippa; Denkinger, Claudia M

    2017-11-01

    Dried blood spots (DBS) are a convenient tool to enable diagnostic testing for viral diseases due to transport, handling and logistical advantages over conventional venous blood sampling. A better understanding of the performance of serological testing for hepatitis C (HCV) and hepatitis B virus (HBV) from DBS is important to enable more widespread use of this sampling approach in resource limited settings, and to inform the 2017 World Health Organization (WHO) guidance on testing for HBV/HCV. We conducted two systematic reviews and meta-analyses on the diagnostic accuracy of HCV antibody (HCV-Ab) and HBV surface antigen (HBsAg) from DBS samples compared to venous blood samples. MEDLINE, EMBASE, Global Health and Cochrane library were searched for studies that assessed diagnostic accuracy with DBS and agreement between DBS and venous sampling. Heterogeneity of results was assessed and where possible a pooled analysis of sensitivity and specificity was performed using a bivariate analysis with maximum likelihood estimate and 95% confidence intervals (95%CI). We conducted a narrative review on the impact of varying storage conditions or limits of detection in subsets of samples. The QUADAS-2 tool was used to assess risk of bias. For the diagnostic accuracy of HBsAg from DBS compared to venous blood, 19 studies were included in a quantitative meta-analysis, and 23 in a narrative review. Pooled sensitivity and specificity were 98% (95%CI:95%-99%) and 100% (95%CI:99-100%), respectively. For the diagnostic accuracy of HCV-Ab from DBS, 19 studies were included in a pooled quantitative meta-analysis, and 23 studies were included in a narrative review. Pooled estimates of sensitivity and specificity were 98% (CI95%:95-99) and 99% (CI95%:98-100), respectively. Overall quality of studies and heterogeneity were rated as moderate in both systematic reviews. HCV-Ab and HBsAg testing using DBS compared to venous blood sampling was associated with excellent diagnostic accuracy. However, generalizability is limited as no uniform protocol was applied and most studies did not use fresh samples. Future studies on diagnostic accuracy should include an assessment of impact of environmental conditions common in low resource field settings. Manufacturers also need to formally validate their assays for DBS for use with their commercial assays.

  6. Mobile compression devices and aspirin for VTE prophylaxis following simultaneous bilateral total knee arthroplasty.

    PubMed

    Nam, Denis; Nunley, Ryan M; Johnson, Staci R; Keeney, James A; Barrack, Robert L

    2015-03-01

    Recently, Levy et al questioned the effectiveness of mobile compression devices (MCDs) as the sole method of thromboprophylaxis following simultaneous bilateral total knee arthroplasty (TKA). This study's purpose was to assess if the addition of aspirin to MCDs improves venous thromboembolism (VTE) prevention following simultaneous bilateral TKA. Ninety-six patients (192 TKAs) were retrospectively reviewed: 47 patients received MCDs for 10 days and aspirin for 6 weeks postoperatively based on a risk stratification protocol, while 49 patients received warfarin for 4 weeks postoperatively. One symptomatic VTE was noted in the warfarin cohort, while one patient in the MCD/aspirin cohort and three patients in the warfarin cohort were readmitted within 3 months of surgery. In appropriately selected patients, MCDs with aspirin shows promise in VTE prevention following simultaneous bilateral TKA. Copyright © 2014 Elsevier Inc. All rights reserved.

  7. Vascular viscoelasticity of perfused rat hindquarters.

    PubMed

    Chihara, E; Morimoto, T; Shigemi, K; Natsuyama, T; Hashimoto, S

    1991-06-01

    To determine viscoelastic features of the rat hindquarters vasculature, we measured pressure-volume curves. Male Wistar rats were transected at the lumbar level, and the perfused hindquarters were oxygenated with a hollow fiber artificial lung. The blood volume was measured by counting 51Cr-labeled red cells led to a gamma counter through an extracorporeal circuit at a constant rate. With continuous monitoring of the venous pressure and circulating blood volume, saline was infused into the circuit from a venous branch for 5 min [1.2 +/- 0.3% (SD) of tissue weight] followed by a 10-min recovery phase. In the recovery phase, the venous pressure promptly declined to the preinfusion level, whereas the circulating blood volume decreased more slowly. This implied vascular stress relaxation of the hindquarters. Maxwell's viscoelastic model, consisting of a spring component and a viscous component, was applied to analyze the venous pressure-volume diagram. With a curve-fitting method, the calculated vascular compliance and relaxation time (a time constant of stress relaxation) were 1.31 +/- 0.14 ml.mmHg-1.kg-1 and 15.7 +/- 4.0 min (means +/- SE), respectively. The value of compliance of the hindquarters was smaller than those of visceral organs reported. In addition, the value for relaxation time suggests that the viscous response of the vasculature simultaneously overlaps change in blood volume due to extravascular fluid shift during the postinfusion period.

  8. Cardiopulmonary Changes with Moderate Decompression in Rats

    NASA Technical Reports Server (NTRS)

    Robinson, R.; Little, T.; Doursout, M.-F.; Butler, B. D.; Chelly, J. E.

    1996-01-01

    Sprague-Dawley rats were compressed to 616 kPa for 120 min then decompressed at 38 kPa/min to assess the cardiovascular and pulmonary responses to moderate decompression stress. In one series of experiments the rats were chronically instrumented with Doppler ultrasonic probes for simultaneous measurement of blood pressure, cardiac output, heart rate, left and right ventricular wall thickening fraction, and venous bubble detection. Data were collected at base-line, throughout the compression/decompression protocol, and for 120 min post decompression. In a second series of experiments the pulmonary responses to the decompression protocol were evaluated in non-instrumented rats. Analyses included blood gases, pleural and bronchoalveolar lavage (BAL) protein and hemoglobin concentration, pulmonary edema, BAL and lung tissue phospholipids, lung compliance, and cell counts. Venous bubbles were directly observed in 90% of the rats where immediate post-decompression autopsy was performed and in 37% using implanted Doppler monitors. Cardiac output, stroke volume, and right ventricular wall thickening fractions were significantly decreased post decompression, whereas systemic vascular resistance was increased suggesting a decrease in venous return. BAL Hb and total protein levels were increased 0 and 60 min post decompression, pleural and plasma levels were unchanged. BAL white blood cells and neutrophil percentages were increased 0 and 60 min post decompression and pulmonary edema was detected. Venous bubbles produced with moderate decompression profiles give detectable cardiovascular and pulmonary responses in the rat.

  9. Combined Ovarian and Adrenal Venous Sampling in the Localization of Adrenocorticotropic Hormone-Independent Ectopic Cushing Syndrome.

    PubMed

    Chen, Shi; Li, Ran; Zhang, Xiaobo; Lu, Lin; Li, Ji; Pan, Hui; Zhu, Huijuan

    2018-03-01

    Cushing syndrome is rarely caused by the secretion of cortisol from ovarian tumors. In clinical decision-making, it is important to determine whether the ovarian tumor is capable of secreting cortisol. Selective ovarian and adrenal venous sampling is scarcely reported in the localization of ACTH-independent ectopic Cushing syndrome. We present a case of 40-year-old Chinese woman who had weight gain, hirsutism, hypertension, and menstrual disorder over 6 months. Her physical examination and biochemical assessment revealed adrenocorticotropic hormone-independent Cushing syndrome. Adrenal computed tomography scan indicated no abnormality. A mass of 5.7 cm × 4.2 cm × 3.4 cm was discovered by pelvic ultrasonography. Somatostatin receptor scintigraphy revealed no abnormal radioactivity intake. Combined ovarian and adrenal venous sampling together with a cortisol assay were conducted. Results revealed cortisol concentration of the right-side ovarian vein, left-side ovarian vein, and peripheral vein of 268.60, 29.00, and 35.18 μg/dL, respectively, suggesting a right-side ovarian origin. A right-side salpingo-oophorectomy was performed and the pathological diagnosis revealed ovarian steroid cell tumor, not otherwise specified. The cortisol level was substantially lower after the patient underwent surgery and symptoms of Cushing syndrome disappeared. At 3-year follow-up, the patient remained disease free, and no tumor was observed on pelvic ultrasonogram. Combined ovarian and adrenal venous sampling is valuable in the localization of adrenocorticotropic hormone-independent ectopic Cushing syndrome.

  10. Use of an Intravascular Fluorescent Continuous Glucose Sensor in ICU Patients.

    PubMed

    Strasma, Paul J; Finfer, Simon; Flower, Oliver; Hipszer, Brian; Kosiborod, Mikhail; Macken, Lewis; Sechterberger, Marjolein; van der Voort, Peter H J; DeVries, J Hans; Joseph, Jeffrey I

    2015-07-01

    Hyperglycemia and hypoglycemia are associated with adverse clinical outcomes in intensive care patients. In product development studies at 4 ICUs, the safety and performance of an intravascular continuous glucose monitoring (IV-CGM) system was evaluated in 70 postsurgical patients. The GluCath System (GluMetrics, Inc) used a quenched chemical fluorescence mechanism to optically measure blood glucose when deployed via a radial artery catheter or directly into a peripheral vein. Periodic ultrasound assessed blood flow and thrombus formation. Patient glucose levels were managed according to the standard of care and existing protocols at each site. Reference blood samples were acquired hourly and compared against prospectively calibrated sensor results. In all, 63 arterial sensors and 9 venous sensors were deployed in 70 patients. Arterial sensors did not interfere with invasive blood pressure monitoring, sampling or other aspects of patient care. A majority of venous sensors (66%) exhibited thrombus on ultrasound. In all, 89.4% (1383/1547) of arterial and 72.2% (182/252) of venous measurements met ISO15197:2003 criteria (within 20%), and 72.7% (1124/1547) of arterial and 56.3% (142/252) of venous measurements met CLSI POCT 12-A3 criteria (within 12.5%). The aggregate mean absolute relative difference (MARD) between the sensors and the reference was 9.6% for arterial and 14.2% for venous sensors. The GluCath System exhibited acceptable accuracy when deployed in a radial artery for up to 48 hours in ICU patients after elective cardiac surgery. Accuracy of venous deployment was substantially lower with significant rates of intravascular thrombus observed using ultrasound. © 2015 Diabetes Technology Society.

  11. Home Treatment of Deep Venous Thrombosis According to Comorbid Conditions.

    PubMed

    Stein, Paul D; Matta, Fadi; Hughes, Mary J

    2016-04-01

    Cautious exploration of the safety of home treatment of deep venous thrombosis has been recommended by many. Our goal was to identify categories of patients with deep venous thrombosis who typically are hospitalized, and categories frequently treated at home. The Nationwide Emergency Department Sample and the Nationwide Inpatient Sample, 2007-2012, were used to determine the number of patients seen in emergency departments throughout the US with deep venous thrombosis and no diagnosis of pulmonary embolism, the proportion of such patients hospitalized according to comorbid conditions and age, the proportion discharged early (≤2 days), and charges for hospitalization and emergency department visits. From 2007-2012, home treatment was selected for 905,152 of 2,671,452 (33.9%) patients with deep venous thrombosis. Home treatment was more frequent in those with no comorbid conditions than with comorbid conditions, 58.0% compared with 15.5% (P <.0001). Early discharge (≤2 days) was in 23.9% with no comorbid conditions, compared with 12.8% with comorbid conditions. Among patients aged 18-50 years, home treatment was selected in 62.9% with no comorbid conditions, compared with 24.2% with comorbid conditions (P <.0001). Among hospitalized patients with no comorbid conditions, 40.7% were aged 18-50 years. Their charges for hospitalization in 2012 were $494 million. Patients aged 50 years or younger with deep venous thrombosis and no comorbid conditions appear to be a group that can be targeted for more frequent home treatment, which would save millions of dollars. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Correlation of Peripheral Vein Tumour Marker Levels, Internal Iliac Vein Tumour Marker Levels and Radical Prostatectomy Specimens in Patients with Prostate Cancer and Borderline High Prostate-Specific Antigen: A Pilot Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Farrelly, Cormac, E-mail: farrellycormac@gmail.com; Lal, Priti; Trerotola, Scott O.

    PurposeTo correlate prostate-specific antigen (PSA), free to total PSA percentage (fPSA%) and prostatic acid phosphatase (PAP) levels from peripheral and pelvic venous samples with prostatectomy specimens in patients with prostate adenocarcinoma and borderline elevation of PSA.Materials and MethodsIn this prospective institutional review board approved study, 7 patients with biopsy proven prostate cancer had a venous sampling procedure prior to prostatectomy (mean 3.2 days, range 1–7). Venous samples were taken from a peripheral vein (PVS), the right internal iliac vein, a deep right internal iliac vein branch, left internal iliac vein and a deep left internal iliac vein branch. Venous sampling resultsmore » were compared to tumour volume, laterality, stage and grade in prostatectomy surgical specimens.ResultsMean PVS PSA was 4.29, range 2.3–6 ng/ml. PSA and PAP values in PVS did not differ significantly from internal iliac or deep internal iliac vein samples (p > 0.05). fPSA% was significantly higher in internal iliac (p = 0.004) and deep internal iliac (p = 0.003) vein samples compared to PVS. One of 7 patients had unilateral tumour only. This patient, with left–sided tumour, had a fPSA% of 6, 6, 6, 14 and 12 in his peripheral, right internal iliac, deep right internal iliac branch, left internal iliac and deep left internal iliac branch samples respectively. There were no adverse events.ConclusionfPSA%, unlike total PSA or PAP, is significantly higher in pelvic vein compared to peripheral vein samples when prostate cancer is present. Larger studies including patients with higher PSA values are warranted to further investigate this counterintuitive finding.« less

  13. The Accuracy of a Near-Infrared Spectroscopy Cerebral Oximetry Device and Its Potential Value for Estimating Jugular Venous Oxygen Saturation

    PubMed Central

    Ikeda, Keita; MacLeod, David B; Grocott, Hilary P.; Moretti, Eugene W.; Ames, Warwick; Vacchiano, Charles

    2014-01-01

    Background An intriguing potential clinical use of cerebral oximeter measurements (SctO2) is the ability to noninvasively estimate jugular bulb venous oxygen saturation (SjvO2). Our purpose in this study was to determine the accuracy of the FORE-SIGHT® (CAS Medical Systems; Branford, CT), which is calibrated to a weighted average of 70% (SjvO2) and 30% arterial saturation, for Food and Drug Administration pre-market approval 510 (k) certification by adapting an industry standard protocol, ISO 9919:2005 [www.ISO.org] (used for pulse oximeters) and to evaluate the use of SctO2 and SpO2 measurements to noninvasively estimate jugular venous oxygen saturation (SnvO2). Methods Paired blood gas samples from the radial artery and the jugular venous bulb were collected from 20 healthy volunteers undergoing progressive oxygen desaturation from 100 to 70%. The blood sample pairs were analyzed via co-oximetry and used to calculate the approximate mixed vascular cerebral blood oxygen saturation, or reference SctO2 values (refSctO2), during increasing hypoxia. These reference values were compared to bilateral FORE-SIGHT SctO2 values recorded simultaneously with the blood gas draws to determine its accuracy. Bilateral SctO2 and SpO2 measurements were then used to calculate SnvO2 values which were compared to SjvO2. Results Two hundred forty-six arterial and 253 venous samples from 18 subjects were used in the analysis. The ipsilateral FORE-SIGHT SctO2 values showed a tolerance interval (TI) of [−10.72 10.90] Lin’s concordance correlation coefficient (CCC) with standard error (SE) of 0.83 ± 0.073 with the refSctO2 values calculated using arterial and venous blood gases. The combined data had a CCC of 0. 81 + 0.059 with TI of [−9.22 9.40] with overall bias was 0.09% and amplitude of the root mean square of error after it was corrected with random effects analysis was 2.92%. The bias and variability values between the ipsilateral and the contralateral FORE-SIGHT SctO2 measurements varied from person to person. The SnvO2 calculated from the ipsilateral SctO2 and SpO2 data showed a CCC + SE of 0.79 ± 0.088, TI = [−14.93 15.33], slope of 0.98, Y-Intercept of 1.14%) with SjvO2 values with a bias of 0.20% and an Arms of 4.08%. The SnvO2 values calculated independently from contralateral forehead FORE-SIGHT SctO2 values were not as correlated with the SjvO2 values (contralateral side CCC + SE = 0.72 ± 0.118, TI = [−14.86 15.20], slope of 0.66 and y-intercept of 20.36%). Conclusions The FORE-SIGHT cerebral oximeter was able to estimate oxygen saturation within the tissues of the frontal lobe under conditions of normocapnia and varying degrees of hypoxia (with 95% confidence interval of [−5.60 5.78] with ipsilateral blood ample data). These findings from healthy volunteers also suggest that the use of the calculated SnvO2 derived from SctO2 and SpO2 values may be a reasonable noninvasive method of estimating SjvO2 and therefore global cerebral oxygen consumption in the clinical setting. Further laboratory and clinical research is required to define the clinical utility of near-infrared spectroscopy determination of SctO2 and SnvO2 in the operating room setting. PMID:25313967

  14. Simultaneous acquisition sequence for improved hepatic pharmacokinetics quantification accuracy (SAHA) for dynamic contrast-enhanced MRI of liver.

    PubMed

    Ning, Jia; Sun, Yongliang; Xie, Sheng; Zhang, Bida; Huang, Feng; Koken, Peter; Smink, Jouke; Yuan, Chun; Chen, Huijun

    2018-05-01

    To propose a simultaneous acquisition sequence for improved hepatic pharmacokinetics quantification accuracy (SAHA) method for liver dynamic contrast-enhanced MRI. The proposed SAHA simultaneously acquired high temporal-resolution 2D images for vascular input function extraction using Cartesian sampling and 3D large-coverage high spatial-resolution liver dynamic contrast-enhanced images using golden angle stack-of-stars acquisition in an interleaved way. Simulations were conducted to investigate the accuracy of SAHA in pharmacokinetic analysis. A healthy volunteer and three patients with cirrhosis or hepatocellular carcinoma were included in the study to investigate the feasibility of SAHA in vivo. Simulation studies showed that SAHA can provide closer results to the true values and lower root mean square error of estimated pharmacokinetic parameters in all of the tested scenarios. The in vivo scans of subjects provided fair image quality of both 2D images for arterial input function and portal venous input function and 3D whole liver images. The in vivo fitting results showed that the perfusion parameters of healthy liver were significantly different from those of cirrhotic liver and HCC. The proposed SAHA can provide improved accuracy in pharmacokinetic modeling and is feasible in human liver dynamic contrast-enhanced MRI, suggesting that SAHA is a potential tool for liver dynamic contrast-enhanced MRI. Magn Reson Med 79:2629-2641, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  15. Peripheral venous vs. capillary microfilariaemia in a dog co-infected with Dirofilaria repens and D. immitis: A comparative approach using triatomine bugs for blood collection.

    PubMed

    Păstrav, Ioana Raluca; Ionică, Angela Monica; Peştean, Cosmin; Novakova, Eva; Modrý, David; Mihalca, Andrei Daniel

    2018-06-15

    Dirofilaria immitis and D. repens are mosquito-borne nematodes, primarily infecting dogs, but also other species of carnivores and even humans. Given their impact on animal and human health, the transmission of these filarioids has been widely studied. The microfilariaemia has been shown to have a circadian variation for both Dirofilaria species infecting dogs. Due to methodological difficulties, the periodicity was only studied using venous blood samples, while the mosquitoes feed, in fact, on capillary blood. In this context, the present study aimed to test the feasibility of using triatomine bugs for the collection of capillary blood and to comparatively evaluate the level of microfilariaemia and its circadian variation in capillary blood vs. peripheral venous blood in a dog naturally co-infected with D. immitis and D. repens. The results showed a feeding success of 50%, with variations in the blood meal volume that the bugs ingested. The relative values of microfilariaemia (mf/bug) were strongly correlated with the volume of blood recovered: the more blood recovered from each bug, the higher values of microfilariaemia in the evening samples while the opposite results were obtained for the morning samples. The counting of microfilariae revealed a dominance of D. immitis in all the samples, but with significantly higher microfilariaemia in the venous blood. Meanwhile, for D. repens, the situation was opposite, with higher counts in the capillary blood samples. Our study showed that triatomine bugs can be used as a model for the collection and study of microfilariaemia in the capillary blood in mammals. Copyright © 2018 Elsevier B.V. All rights reserved.

  16. Computational modeling of venous sinus stenosis in idiopathic intracranial hypertension

    PubMed Central

    Levitt, Michael R; McGah, Patrick M; Moon, Karam; Albuquerque, Felipe C; McDougall, Cameron G; Kalani, M Yashar S; Kim, Louis J; Aliseda, Alberto

    2016-01-01

    Background and Purpose Idiopathic intracranial hypertension has been associated with dural venous sinus stenosis in some patients, but the hemodynamic environment of the dural venous sinuses has not been quantitatively described. Here, we present the first such computational fluid dynamics model using patient-specific blood pressure measurements. Materials and Methods Six patients with idiopathic intracranial hypertension and at least one stenosis or atresia at the transverse-sigmoid sinus junction underwent MRV followed by cerebral venography and manometry throughout the dural venous sinuses. Patient-specific computational fluid dynamics models were created using MRV anatomy, with venous pressure measurements as boundary conditions. Blood flow and wall shear stress were calculated for each patient. Results Computational models of dural venous sinuses were successfully reconstructed in all six patients with patient-specific boundary conditions. Three patients demonstrated a pathologic pressure gradient (≥ 8 mm Hg) across four dural venous sinus stenoses. Small sample size precludes statistical comparisons, but average overall flow throughout the dural venous sinuses of patients with pathologic pressure gradients was higher than in those without (1041.00 ± 506.52 vs. 358.00 ± 190.95 mL/min). Wall shear stress was also higher across stenoses in patients with pathologic pressure gradients (37.66 ± 48.39 vs 7.02 ± 13.60 Pa). Conclusion The hemodynamic environment of the dural venous sinuses can be computationally modeled using patient-specific anatomy and physiological measurements in patients with idiopathic intracranial hypertension. There was substantially higher blood flow and wall shear stress in patients with pathological pressure gradients. PMID:27197986

  17. Successful treatment of acquired uterine arterial venous malformation using N-butyl-2-cyanoacrylate under balloon occlusion

    PubMed Central

    Ogasawara, Go; Ishida, Kenichiro; Fujii, Kaoru; Yamane, Takuro; Nishimaki, Hiroshi; Matsunaga, Keiji; Inoue, Yusuke

    2014-01-01

    We present two cases of acquired uterine arterial venous malformation (AVM) which was diagnosed because of massive genital bleeding successfully treated with transcatheter arterial embolization (TAE), using N-butyl-2-cyanoacrylate (NBCA) under balloon occlusion. Balloon occlusion at the uterine artery was performed in both patients for diffuse distribution of NBCA in multiple feeding branches, as well as to the pseudoaneurysm, and for the prevention of NBCA reflux. In one of our patients, balloon occlusion of the draining vein was simultaneously performed to prevent NBCA migration through accompanying high-flow arteriovenous fistula (AVF). Doppler ultrasound at 6 months of both patients documented persistent complete occlusion of AVM. Complete and safe obliteration of acquired uterine AVM was accomplished using NBCA as embolic agent, under balloon occlusion at the communicating vessels of acquired uterine AVM. PMID:25346850

  18. Distortion of calculated whole-body hematocrit during lower-body immersion in water.

    PubMed

    Knight, D R; Santoro, T; Bondi, K R

    1986-11-01

    We found a difference between the venous hematocrits of immersed and nonimmersed arms during immersion of the lower body in cold water but not during a comparable exposure to warm water. Fourteen healthy men were exposed to three different experimental conditions: arm immersion, body immersion, and control. The men always sat upright while both upper extremities hung vertically at their sides. During arm immersion, one forearm was completely immersed for 30 min in either cold water (28 degrees C, n = 7) or warm water (38 degrees C, n = 7). This cold-warm water protocol was repeated on separate days for exposure to the remaining conditions of body immersion (immersion of 1 forearm and all tissues below the xiphoid process) and control (no immersion). Blood samples were simultaneously drawn from cannulated veins in both antecubital fossae. Hematocrit difference (Hct diff) was measured by subtracting the nonimmersed forearm's hematocrit (Hct dry) from the immersed forearm's hematocrit (Hct wet). Hct diff was approximately zero when the men were exposed to the control condition and body immersion in warm water. In the remaining conditions, Hct wet dropped below Hct dry (P less than 0.01, 3-way analysis of variance). The decrements of Hct diff showed there were differences between venous hematocrits in immersed and nonimmersed regions of the body, indicating that changes of the whole-body hematocrit cannot be calculated from a large-vessel hematocrit soon after immersing the lower body in cold water.

  19. The agreement between abnormal venous lactate and arterial lactate in the ED: a retrospective chart review.

    PubMed

    Bloom, B; Pott, J; Freund, Y; Grundlingh, J; Harris, T

    2014-06-01

    The evidence for prognostication using lactate is often based on arterial lactate (AL). Arterial sampling is painful and difficult, and carries risks. Studies comparing peripheral venous lactate (PVL) with AL showed little difference but predominantly included patients with normal lactate. The objective of this study was to measure agreement between PVL and AL in patients with elevated venous lactate. This is a retrospective cross-sectional study. ED patients age≥16, attending from October 2010 to June 2011 inclusive, with PVL≥2.0 mmol/L and AL taken within 1 hour. intravenous fluid prior to or between initial venous and arterial sampling. Primary endpoint: agreement between PVL and AL defined as mean difference±95% limits of agreement (LOA). The misclassification rate was assessed. N=232. VL median 3.50 mmol/L, range 2.00 to 15.00 mmol/L. AL median 2.45 mmol/L, range 1.0 to 13.2 mmol/L. The mean difference±SD between PVL and AL for all patients was 1.06±1.30 mmol/L (95%LOA -1.53 to 3.66 mmol/L). Using a cut-off of 2 mmol/L and 4 mmol/L, 36.2% and 17.9% of patients respectively were incorrectly classified as having elevated lactate. We report greater bias between VL and AL with broader LOA than previously documented. This may partly be due to the fact that we studied only patients with abnormal venous values, for whom close agreement would confer greatest clinical significance. The agreement between abnormal PVL and AL is poor and the high rate of misclassification may suggest that PVL is not a good substitute for AL if the venous lactate is abnormal. Copyright © 2014 Elsevier Inc. All rights reserved.

  20. Compression ultrasonography of the lower extremity with portable vascular ultrasonography can accurately detect deep venous thrombosis in the emergency department.

    PubMed

    Crisp, Jonathan G; Lovato, Luis M; Jang, Timothy B

    2010-12-01

    Compression ultrasonography of the lower extremity is an established method of detecting proximal lower extremity deep venous thrombosis when performed by a certified operator in a vascular laboratory. Our objective is to determine the sensitivity and specificity of bedside 2-point compression ultrasonography performed in the emergency department (ED) with portable vascular ultrasonography for the detection of proximal lower extremity deep venous thrombosis. We did this by directly comparing emergency physician-performed ultrasonography to lower extremity duplex ultrasonography performed by the Department of Radiology. This was a prospective, cross-sectional study and diagnostic test assessment of a convenience sample of ED patients with a suspected lower extremity deep venous thrombosis, conducted at a single-center, urban, academic ED. All physicians had a 10-minute training session before enrolling patients. ED compression ultrasonography occurred before Department of Radiology ultrasonography and involved identification of 2 specific points: the common femoral and popliteal vessels, with subsequent compression of the common femoral and popliteal veins. The study result was considered positive for proximal lower extremity deep venous thrombosis if either vein was incompressible or a thrombus was visualized. Sensitivity and specificity were calculated with the final radiologist interpretation of the Department of Radiology ultrasonography as the criterion standard. A total of 47 physicians performed 199 2-point compression ultrasonographic examinations in the ED. Median number of examinations per physician was 2 (range 1 to 29 examinations; interquartile range 1 to 5 examinations). There were 45 proximal lower extremity deep venous thromboses observed on Department of Radiology evaluation, all correctly identified by ED 2-point compression ultrasonography. The 153 patients without proximal lower extremity deep venous thrombosis all had a negative ED compression ultrasonographic result. One patient with a negative Department of Radiology ultrasonographic result was found to have decreased compression of the popliteal vein on ED compression ultrasonography, giving a single false-positive result, yet repeated ultrasonography by the Department of Radiology 1 week later showed a popliteal deep venous thrombosis. The sensitivity and specificity of ED 2-point compression ultrasonography for deep venous thrombosis were 100% (95% confidence interval 92% to 100%) and 99% (95% confidence interval 96% to 100%), respectively. Emergency physician-performed 2-point compression ultrasonography of the lower extremity with a portable vascular ultrasonographic machine, conducted in the ED by this physician group and in this patient sample, accurately identified the presence and absence of proximal lower extremity deep venous thrombosis. Copyright © 2010 American College of Emergency Physicians. Published by Mosby, Inc. All rights reserved.

  1. Pentoxifylline for treating venous leg ulcers.

    PubMed

    Jull, A; Arroll, B; Parag, V; Waters, J

    2007-07-18

    Healing of venous leg ulcers is improved by the use of compression bandaging but some venous ulcers remain unhealed, and some people are unsuitable for compression therapy. Pentoxifylline, a drug which helps blood flow, has been used to treat venous leg ulcers. An earlier version of this review included 9 randomised controlled trials, but more research has been since been conducted and an updated review is required. To assess the effects of pentoxifylline (oxpentifylline or Trental 400) for treating venous leg ulcers, compared with placebo, or other therapies, in the presence or absence of compression therapy. For this second update we searched the Cochrane Wounds Group Specialised Register, CENTRAL, MEDLINE, EMBASE and Cinahl (date of last search was February 2007), and reference lists of relevant articles. Randomised trials comparing pentoxifylline with placebo or other therapy in the presence or absence of compression, in people with venous leg ulcers. Details from eligible trials were extracted and summarised by one author using a coding sheet. Data extraction was independently verified by one other author. Twelve trials involving 864 participants were included. The quality of trials was variable. Eleven trials compared pentoxifylline with placebo or no treatment; in seven of these trials patients received compression therapy. In one trial pentoxifylline was compared with defibrotide in patients who also received compression. Combining 11 trials that compared pentoxifylline with placebo or no treatment (with or without compression) demonstrated that pentoxifylline is more effective than placebo in terms of complete ulcer healing or significant improvement (RR 1.70, 95% CI 1.30 to 2.24). Significant heterogeneity was associated with differences in sample populations (hard-to-heal samples compared with "normal" healing samples). Pentoxifylline plus compression is more effective than placebo plus compression (RR 1.56, 95% CI 1.14 to 2.13). Pentoxifylline in the absence of compression appears to be more effective than placebo or no treatment (RR 2.25, 95% CI 1.49 to 3.39). A comparison between pentoxifylline and defibrotide found no statistically significant difference in healing rates. More adverse effects were reported in people receiving pentoxifylline (RR 1.56, 95% CI 1.10 to 2.22). Nearly three-quarters (72%) of the reported adverse effects were gastrointestinal. Pentoxifylline is an effective adjunct to compression bandaging for treating venous ulcers and may be effective in the absence of compression. The majority of adverse effects were gastrointestinal disturbances.

  2. Correlation of Lactic Acid and Base Deficit Values Obtained From Arterial and Peripheral Venous Samples in a Pediatric Population During Intraoperative Care.

    PubMed

    Bordes, Brianne M; Walia, Hina; Sebastian, Roby; Martin, David; Tumin, Dmitry; Tobias, Joseph D

    2017-12-01

    Lactic acid and base deficit (BD) values are frequently monitored in the intensive care unit and operating room setting to evaluate oxygenation, ventilation, cardiac output, and peripheral perfusion. Although generally obtained from an arterial cannula, such access may not always be available. The current study prospectively investigates the correlation of arterial and peripheral venous values of BD and lactic acid. The study cohort included 48 patients. Arterial BD values ranged from -8 to 4 mEq/L and peripheral venous BD values ranged from -8 to 4 mEq/L. Arterial lactic acid values ranged from 0.36 to 2.45 μmol/L and peripheral venous lactic acid values ranged from 0.38 to 4 μmol/L. The arterial BD (-0.4 ± 2.2 mEq/L) was not significantly different from the peripheral venous BD (-0.6 ± 2.2 mEq/L). The arterial lactic acid (1.0 ± 0.5 μmol/L) was not significantly different from the peripheral venous lactic acid (1.1 ± 0.6 μmol/L). Pearson correlation coefficients demonstrated a very high correlation between arterial and peripheral venous BD ( r = .88, P < .001) and between arterial and peripheral venous lactic acid ( r = .67, P < .001). Bland-Altman plots of both pairs of measures showed that the majority of observations fell within the 95% limits of agreement. Least-squares regression indicated that a 1-unit increase in arterial BD corresponded to a 0.9-unit increase in peripheral venous BD (95% confidence interval [CI]: 0.7-1.0; P < .001) and a 1-unit increase in arterial lactic acid corresponded to a 0.9-unit increase in peripheral venous lactic acid (95% CI: 0.6-1.2; P < .001). These data demonstrate that there is a clinically useful correlation between arterial and peripheral venous lactic acid and BD values.

  3. Single-Session Percutaneous Endovascular Mesocaval Shunt Creation and Balloon-Occluded Retrograde Transvenous Obliteration for the Treatment of Gastric Varices.

    PubMed

    Srinivasa, Ravi Nara; Majdalany, Bill S; Chick, Jeffrey Forris Beecham; Meadows, J Matthew; Fenlon, Jordan Bruce; Brewerton, Charles; Saad, Wael E

    2018-01-01

    In the setting of portal hypertension, the body responds by creating portosystemic venous shunts, which may lead to the development of varices. Endoscopic treatment of these varices is often warranted to prevent catastrophic bleeding. During the course of variceal treatment, 1 or more portosystemic shunts may be sacrificed, which may acutely exacerbate portal hypertension and reduce systemic venous return. This report describes percutaneous creation of a mesocaval shunt and balloon-occluded retrograde transvenous obliteration (BRTO) in a patient with cavernous transformation of the portal vein. The patient had previously undergone an unsuccessful attempt at transjugular intrahepatic portosystemic shunt (TIPS) creation with postoperative bleeding requiring splenectomy. As TIPS was not feasible, creation of a percutaneous mesocaval shunt provided an alternate pathway for portosystemic decompression, facilitating safe treatment of gastric varices with BRTO via a gastrorenal shunt. These procedures were performed simultaneously to reduce the risk of variceal bleeding from acute changes in portal venous pressures and redirect blood flow through the shunt to maintain patency. This is the first reported case of combined mesocaval shunt placement and BRTO in a single session. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Nitrite and S-Nitrosohemoglobin Exchange Across the Human Cerebral and Femoral Circulation: Relationship to Basal and Exercise Blood Flow Responses to Hypoxia.

    PubMed

    Bailey, Damian M; Rasmussen, Peter; Overgaard, Morten; Evans, Kevin A; Bohm, Aske M; Seifert, Thomas; Brassard, Patrice; Zaar, Morten; Nielsen, Henning B; Raven, Peter B; Secher, Niels H

    2017-01-10

    The mechanisms underlying red blood cell (RBC)-mediated hypoxic vasodilation remain controversial, with separate roles for nitrite () and S-nitrosohemoglobin (SNO-Hb) widely contested given their ability to transduce nitric oxide bioactivity within the microcirculation. To establish their relative contribution in vivo, we quantified arterial-venous concentration gradients across the human cerebral and femoral circulation at rest and during exercise, an ideal model system characterized by physiological extremes of O 2 tension and blood flow. Ten healthy participants (5 men, 5 women) aged 24±4 (mean±SD) years old were randomly assigned to a normoxic (21% O 2 ) and hypoxic (10% O 2 ) trial with measurements performed at rest and after 30 minutes of cycling at 70% of maximal power output in hypoxia and equivalent relative and absolute intensities in normoxia. Blood was sampled simultaneously from the brachial artery and internal jugular and femoral veins with plasma and RBC nitric oxide metabolites measured by tri-iodide reductive chemiluminescence. Blood flow was determined by transcranial Doppler ultrasound (cerebral blood flow) and constant infusion thermodilution (femoral blood flow) with net exchange calculated via the Fick principle. Hypoxia was associated with a mild increase in both cerebral blood flow and femoral blood flow (P<0.05 versus normoxia) with further, more pronounced increases observed in femoral blood flow during exercise (P<0.05 versus rest) in proportion to the reduction in RBC oxygenation (r=0.680-0.769, P<0.001). Plasma gradients reflecting consumption (arterial>venous; P<0.05) were accompanied by RBC iron nitrosylhemoglobin formation (venous>arterial; P<0.05) at rest in normoxia, during hypoxia (P<0.05 versus normoxia), and especially during exercise (P<0.05 versus rest), with the most pronounced gradients observed across the bioenergetically more active, hypoxemic, and acidotic femoral circulation (P<0.05 versus cerebral). In contrast, we failed to observe any gradients consistent with RBC SNO-Hb consumption and corresponding delivery of plasma S-nitrosothiols (P>0.05). These findings suggest that hypoxia and, to a far greater extent, exercise independently promote arterial-venous delivery gradients of intravascular nitric oxide, with deoxyhemoglobin-mediated reduction identified as the dominant mechanism underlying hypoxic vasodilation. © 2016 American Heart Association, Inc.

  5. Central Vein Dilatation Prior to Concomitant Port Implantation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Krombach, Gabriele A., E-mail: krombach@rad.rwth-aachen.de; Plumhans, Cedric; Goerg, Fabian

    2010-04-15

    Implantation of subcutaneous port systems is routinely performed in patients requiring repeated long-term infusion therapy. Ultrasound- and fluoroscopy-guided implantation under local anesthesia is broadly established in interventional radiology and has decreased the rate of complications compared to the surgical approach. In addition, interventional radiology offers the unique possibility of simultaneous management of venous occlusion. We present a technique for recanalization of central venous occlusion and angioplasty combined with port placement in a single intervention which we performed in two patients. Surgical port placement was impossible owing to occlusion of the superior vena cava following placement of a cardiac pacemaker andmore » occlusion of multiple central veins due to paraneoplastic coagulopathy, respectively. In both cases the affected vessel segments were dilated with balloon catheters and the port systems were placed thereafter. After successful dilatation, the venous access was secured with a 25-cm-long, 8-Fr introducer sheath, a subcutaneous pocket prepared, and the port catheter tunneled to the venipuncture site. The port catheter was introduced through the sheath with the proximal end connected to a 5-Fr catheter. This catheter was pulled through the tunnel in order to preserve the tunnel and, at the same time, allow safe removal of the long sheath over the wire. The port system functioned well in both cases. The combination of recanalization and port placement in a single intervention is a straightforward alternative for patients with central venous occlusion that can only be offered by interventional radiology.« less

  6. Optoacoustic monitoring of central and peripheral venous oxygenation during simulated hemorrhage

    NASA Astrophysics Data System (ADS)

    Petrov, Andrey; Kinsky, Michael; Prough, Donald S.; Petrov, Yuriy; Petrov, Irene Y.; Henkel, S. Nan; Seeton, Roger; Salter, Michael G.; Khan, Muzna N.; Esenaliev, Rinat O.

    2014-03-01

    Circulatory shock may be fatal unless promptly recognized and treated. The most commonly used indicators of shock (hypotension and tachycardia) lack sensitivity and specificity. In the initial stages of shock, the body compensates by reducing blood flow to the peripheral (skin, muscle, etc.) circulation in order to preserve vital organ (brain, heart, liver) perfusion. Characteristically, this can be observed by a greater reduction in peripheral venous oxygenation (for instance, the axillary vein) compared to central venous oxygenation (the internal jugular vein). While invasive measurements of oxygenation are accurate, they lack practicality and are not without complications. We have developed a novel optoacoustic system that noninvasively determines oxygenation in specific veins. In order to test this application, we used lower body negative pressure (LBNP) system, which simulates hemorrhage by exerting a variable amount of suction on the lower body, thereby reducing the volume of blood available for central circulation. Restoration of normal blood flow occurs promptly upon cessation of LBNP. Using two optoacoustic probes, guided by ultrasound imaging, we simultaneously monitored oxygenation in the axillary and internal jugular veins (IJV). LBNP began at -20 mmHg, thereafter was reduced in a step-wise fashion (up to 30 min). The optoacoustically measured axillary oxygenation decreased with LBNP, whereas IJV oxygenation remained relatively constant. These results indicate that our optoacoustic system may provide safe and rapid measurement of peripheral and central venous oxygenation and diagnosis of shock with high specificity and sensitivity.

  7. Venous access and care: harnessing pragmatics in harm reduction for people who inject drugs.

    PubMed

    Harris, Magdalena; Rhodes, Tim

    2012-06-01

    To explore the facilitators of long-term hepatitis C avoidance among people who inject drugs. We employed a qualitative life history design. Recruitment took place through low-threshold drug services and drug user networks in South East and North London. Participants were interviewed at the recruitment services or in their homes. The sample comprised 35 people who inject drugs, 20 of whom were hepatitis C antibody-negative. Participants' average injecting trajectory was 19 years (6-33), with 66% primarily injecting heroin, and 34% a crack and heroin mix. Nine (26%) of the sample were female and the average age was 39 years (23-53). Two interviews were conducted with each participant, with the second interview incorporating reference to a computer-constructed life history time-line. Interview accounts were audiorecorded, transcribed verbatim and analysed thematically. Hepatitis C risk awareness was recent and deprioritized by the majority of participants. The facilitation of venous access and care was an initial and enduring rationale for safe injecting practices. Difficult venous access resulted in increased contamination of injecting environments and transitions to femoral injecting. Participants expressed an unmet desire for non-judgemental venous access information and advice. Harm reduction interventions which attend to the immediate priorities of people who inject drugs, such as venous access and care, have the potential to re-engage individuals who are jaded or confused by hepatitis C prevention messages. © 2011 The Authors, Addiction © 2011 Society for the Study of Addiction.

  8. Noninvasive oxygen monitoring techniques.

    PubMed

    Wahr, J A; Tremper, K K

    1995-01-01

    As this article demonstrates, tremendous progress has been made in the techniques of oxygen measurement and monitoring over the past 50 years. From the early developments during and after World War II, to the most recent applications of solid state and microprocessor technology today, every patient in a critical care situation will have several continuous measurements of oxygenation applied simultaneously. Information therefore is available readily to alert personnel of acute problems and to guide appropriate therapy. The majority of effort to date has been placed on measuring oxygenation of arterial or venous blood. The next generation of devices will attempt to provide information about living tissue. Unlike the devices monitoring arterial or venous oxygen content, no "gold standards" exist for tissue oxygenation, so calibration will be difficult, as will interpretation of the data provided. The application of these devices ultimately may lead to a much better understanding of how disease (and the treatment of disease) alters the utilization of oxygen by the tissues.

  9. A case of adrenal Cushing's syndrome with bilateral adrenal masses.

    PubMed

    Guo, Ya-Wun; Hwu, Chii-Min; Won, Justin Ging-Shing; Chu, Chia-Huei; Lin, Liang-Yu

    2016-01-01

    A functional lesion in corticotrophin (ACTH)-independent Cushing's syndrome is difficult to distinguish from lesions of bilateral adrenal masses. Methods for distinguishing these lesions include adrenal venous sampling and (131)I-6β-iodomethyl-19-norcholesterol ((131)I-NP-59) scintigraphy. We present a case of a 29-year-old Han Chinese female patient with a history of hypercholesterolaemia and polycystic ovary syndrome. She presented with a 6month history of an 8kg body weight gain and gradual rounding of the face. Serial examinations revealed loss of circadian rhythm of cortisol, elevated urinary free-cortisol level and undetectable ACTH level (<5pg/mL). No suppression was observed in both the low- and high-dose dexamethasone suppression tests. Adrenal computed tomography revealed bilateral adrenal masses. Adrenal venous sampling was performed, and the right-to-left lateralisation ratio was 14.29. The finding from adrenal scintigraphy with NP-59 was consistent with right adrenal adenoma. The patient underwent laparoscopic right adrenalectomy, and the pathology report showed adrenocortical adenoma. Her postoperative cortisol level was 3.2μg/dL, and her Cushingoid appearance improved. In sum, both adrenal venous sampling and (131)I-NP-59 scintigraphy are good diagnostic methods for Cushing's syndrome presenting with bilateral adrenal masses. The clinical presentation of Cushing' syndrome includes symptoms and signs of fat redistribution and protein-wasting features.The diagnosis of patients with ACTH-independent Cushing's syndrome with bilateral adrenal masses is challenging for localisation of the lesion.Both adrenal venous sampling and (131)I-NP-59 scintigraphy are good methods to use in these patients with Cushing's syndrome presenting with bilateral adrenal masses.

  10. Label-free single-cell separation and imaging of cancer cells using an integrated microfluidic system

    PubMed Central

    Antfolk, Maria; Kim, Soo Hyeon; Koizumi, Saori; Fujii, Teruo; Laurell, Thomas

    2017-01-01

    The incidence of cancer is increasing worldwide and metastatic disease, through the spread of circulating tumor cells (CTCs), is responsible for the majority of the cancer deaths. Accurate monitoring of CTC levels in blood provides clinical information supporting therapeutic decision making, and improved methods for CTC enumeration are asked for. Microfluidics has been extensively used for this purpose but most methods require several post-separation processing steps including concentration of the sample before analysis. This induces a high risk of sample loss of the collected rare cells. Here, an integrated system is presented that efficiently eliminates this risk by integrating label-free separation with single cell arraying of the target cell population, enabling direct on-chip tumor cell identification and enumeration. Prostate cancer cells (DU145) spiked into a sample with whole blood concentration of the peripheral blood mononuclear cell (PBMC) fraction were efficiently separated and trapped at a recovery of 76.2 ± 5.9% of the cancer cells and a minute contamination of 0.12 ± 0.04% PBMCs while simultaneously enabling a 20x volumetric concentration. This constitutes a first step towards a fully integrated system for rapid label-free separation and on-chip phenotypic characterization of circulating tumor cells from peripheral venous blood in clinical practice. PMID:28425472

  11. Label-free single-cell separation and imaging of cancer cells using an integrated microfluidic system.

    PubMed

    Antfolk, Maria; Kim, Soo Hyeon; Koizumi, Saori; Fujii, Teruo; Laurell, Thomas

    2017-04-20

    The incidence of cancer is increasing worldwide and metastatic disease, through the spread of circulating tumor cells (CTCs), is responsible for the majority of the cancer deaths. Accurate monitoring of CTC levels in blood provides clinical information supporting therapeutic decision making, and improved methods for CTC enumeration are asked for. Microfluidics has been extensively used for this purpose but most methods require several post-separation processing steps including concentration of the sample before analysis. This induces a high risk of sample loss of the collected rare cells. Here, an integrated system is presented that efficiently eliminates this risk by integrating label-free separation with single cell arraying of the target cell population, enabling direct on-chip tumor cell identification and enumeration. Prostate cancer cells (DU145) spiked into a sample with whole blood concentration of the peripheral blood mononuclear cell (PBMC) fraction were efficiently separated and trapped at a recovery of 76.2 ± 5.9% of the cancer cells and a minute contamination of 0.12 ± 0.04% PBMCs while simultaneously enabling a 20x volumetric concentration. This constitutes a first step towards a fully integrated system for rapid label-free separation and on-chip phenotypic characterization of circulating tumor cells from peripheral venous blood in clinical practice.

  12. Mycobacterium phocaicum bacteremia: an emerging infection in pediatric hematology-oncology patients.

    PubMed

    Shachor-Meyouhas, Yael; Geffen, Yuval; Arad-Cohen, Nira; Zaidman, Irina; Ben-Barak, Ayelet; Davidson, Sima; Kassis, Imad

    2014-12-01

    Nontuberculous mycobacteria may cause central venous catheter-associated bacteremia. Between March 2011 and October 2013, 6 cases of Mycobacterium phocaicum bacteremia were found in the pediatric hematology-oncology department. All patients recovered. No positive blood culture was documented after removal of the central venous catheter. All 4 patients with pulsed field gel electrophoresis had the same pattern, different from the water sample, suggesting a common water source.

  13. Filterability of freshly-collected sickle erythrocytes under venous oxygen pressure without exposure to air.

    PubMed

    Shah, Siddharth; Acholonu, Rhonda Graves; Ohene-Frempong, Kwaku; Asakura, Toshio

    2015-12-01

    We previously found that blood samples collected from steady-state patients with sickle cell disease (SCD) without exposure to air contain a new type of reversibly sickled cells (RSCs) with blunt edges at a level of as high as 78%. Since partial oxygenation of once-deoxygenated sickled cells with pointy edges to near venous oxygen pressure generates similar sickled cells with blunt edges in vitro, we named them as partially oxygenated sickled cells (POSCs). On the other hand, partial deoxygenation of once-oxygenated SS cells to venous oxygen pressure generates partially deoxygenated sickled cells (PDSCs) with pointy edges. In this study, we obtained blood samples from 6 steady-state patients with SCD under venous oxygen pressure without exposure to air, subjected them to various oxygenation/deoxygenation/reoxygenation cycles, and studied their filterability through a membrane filter with pore diameter of 3μm, the theoretical minimum diameter of a capillary. Our results indicated that discocytes, POSCs with blunt edges, and irreversibly sickled cells could deform and pass through the filter, while PDSCs with pointy edges were rigid and could not. The filterability of SS cells seems to be related to the length and amount of deoxy-hemoglobin S fibers in the cells. Copyright © 2015. Published by Elsevier Inc.

  14. Dynamic Liver Magnetic Resonance Imaging in Free-Breathing: Feasibility of a Cartesian T1-Weighted Acquisition Technique With Compressed Sensing and Additional Self-Navigation Signal for Hard-Gated and Motion-Resolved Reconstruction.

    PubMed

    Kaltenbach, Benjamin; Bucher, Andreas M; Wichmann, Julian L; Nickel, Dominik; Polkowski, Christoph; Hammerstingl, Renate; Vogl, Thomas J; Bodelle, Boris

    2017-11-01

    The aim of this study was to assess the feasibility of a free-breathing dynamic liver imaging technique using a prototype Cartesian T1-weighted volumetric interpolated breathhold examination (VIBE) sequence with compressed sensing and simultaneous acquisition of a navigation signal for hard-gated and motion state-resolved reconstruction. A total of 43 consecutive oncologic patients (mean age, 66 ± 11 years; 44% female) underwent free-breathing dynamic liver imaging for the evaluation of liver metastases from colorectal cancer using a prototype Cartesian VIBE sequence (field of view, 380 × 345 mm; image matrix, 320 × 218; echo time/repetition time, 1.8/3.76 milliseconds; flip angle, 10 degrees; slice thickness, 3.0 mm; acquisition time, 188 seconds) with continuous data sampling and additionally acquired self-navigation signal. Data were iteratively reconstructed using 2 different approaches: first, a hard-gated reconstruction only using data associated to the dominating motion state (CS VIBE, Compressed Sensing VIBE), and second, a motion-resolved reconstruction with 6 different motion states as additional image dimension (XD VIBE, eXtended dimension VIBE). Continuous acquired data were grouped in 16 subsequent time increments with 11.57 seconds each to resolve arterial and venous contrast phases. For image quality assessment, both CS VIBE and XD VIBE were compared with the patient's last staging dynamic liver magnetic resonance imaging including a breathhold (BH) VIBE as reference standard 4.5 ± 1.2 months before. Representative quality parameters including respiratory artifacts were evaluated for arterial and venous phase images independently, retrospectively and blindly by 3 experienced radiologists, with higher scores indicating better examination quality. To assess diagnostic accuracy, same readers evaluated the presence of metastatic lesions for XD VIBE and CS VIBE compared with reference BH examination in a second session. Compared with CS VIBE, XD VIBE showed significantly higher overall image quality for both arterial phase (4.2 ± 0.6 vs 3.8 ± 0.7, P = 0.008) and venous phase (4.7 ± 0.4 vs 4.3 ± 0.7, P < 0.001) imaging. There was no significant difference between XD VIBE and BH VIBE for overall image quality in the venous phase (4.7 ± 0.4 vs 4.8 ± 0.4, P = 0.834), whereas arterial phase images were scored slightly lower for XD VIBE (4.5 ± 0.6 vs 4.2 ± 0.6, P = 0.024). Both XD VIBE and BH VIBE were characterized by a very low level of respiratory artifacts with no significant difference between BH and motion-resolved free-breathing strategy (P = 0.505 for arterial phase; P = 0.496 for venous phase). Compared with CS VIBE, obvious quality improvement could be achieved for the extended XD VIBE reconstruction with significantly reduced motion artifacts for venous phase images (P = 0.007). Generally, arterial phase images were scored slightly lower compared with venous phase images when using the free-breathing protocol. Overall, 98% of all metastatic lesions were identified on XD VIBE images and 92% of all metastases were found on CS VIBE. Dynamic liver imaging using the proposed free-breathing Cartesian strategy is feasible in oncologic patients with excellent image quality, high respiratory motion robustness, and accurate lesion detection. Overall, XD VIBE was superior to CS VIBE in our study.

  15. NHEXAS PHASE I REGION 5 STUDY--METALS IN BLOOD ANALYTICAL RESULTS

    EPA Science Inventory

    This data set includes analytical results for measurements of metals in 165 blood samples. These samples were collected to examine the relationships between personal exposure measurements, environmental measurements, and body burden. Venous blood samples were collected by venipun...

  16. NHEXAS PHASE I REGION 5 STUDY--VOCS IN BLOOD ANALYTICAL RESULTS

    EPA Science Inventory

    This data set includes analytical results for measurements of VOCs (volatile organic compounds) in 145 blood samples. These samples were collected to examine the relationships between personal exposure measurements, environmental measurements, and body burden. Venous blood sample...

  17. Comparison of Three Screening Test Kits for G6PD Enzyme Deficiency: Implications for Its Use in the Radical Cure of Vivax Malaria in Remote and Resource-Poor Areas in the Philippines.

    PubMed

    Espino, Fe Esperanza; Bibit, Jo-Anne; Sornillo, Johanna Beulah; Tan, Alvin; von Seidlein, Lorenz; Ley, Benedikt

    2016-01-01

    We evaluated a battery of Glucose-6-Phosphate Dehydrogenase diagnostic point-of-care tests (PoC) to assess the most suitable product in terms of performance and operational characteristics for remote areas. Samples were collected in Puerto Princesa City, Palawan, Philippines and tested for G6PD deficiency with a fluorescent spot test (FST; Procedure 203, Trinity Biotech, Ireland), the semiquantitative WST8/1-methoxy PMS (WST; Dojindo, Japan) and the Carestart G6PD Rapid Diagnostic Test (CSG; AccessBio, USA). Results were compared to spectrophotometry (Procedure 345, Trinity Biotech, Ireland). Sensitivity and specificity were calculated for each test with cut-off activities of 10%, 20%, 30% and 60% of the adjusted male median. The adjusted male median was 270.5 IU/10(12) RBC. FST and WST were tested on 621 capillary blood samples, the CSG was tested on venous and capillary blood on 302 samples. At 30% G6PD activity, sensitivity for the FST was between 87.7% (95%CI: 76.8% to 93.9%) and 96.5% (95%CI: 87.9% to 99.5%) depending on definition of intermediate results; the WST was 84.2% (95%CI: 72.1% to 92.5%); and the CSG was between 68.8% (95%CI: 41.3% to 89.0%) and 93.8% (95%CI: 69.8% to 99.8%) when the test was performed on capillary or venous blood respectively. Sensitivity of FST and CSG (tested with venous blood) were comparable (p>0.05). The analysis of venous blood samples by the CSG yielded significantly higher results than FST and CSG performed on capillary blood (p<0.05). Sensitivity of the CSG varied depending on source of blood used (p<0.05). The operational characteristics of the CSG were superior to all other test formats. Performance and operational characteristics of the CSG performed on venous blood suggest the test to be a good alternative to the FST.

  18. Comparison of Three Screening Test Kits for G6PD Enzyme Deficiency: Implications for Its Use in the Radical Cure of Vivax Malaria in Remote and Resource-Poor Areas in the Philippines

    PubMed Central

    Espino, Fe Esperanza; Sornillo, Johanna Beulah; Tan, Alvin; von Seidlein, Lorenz

    2016-01-01

    Objective We evaluated a battery of Glucose-6-Phosphate Dehydrogenase diagnostic point-of-care tests (PoC) to assess the most suitable product in terms of performance and operational characteristics for remote areas. Methods Samples were collected in Puerto Princesa City, Palawan, Philippines and tested for G6PD deficiency with a fluorescent spot test (FST; Procedure 203, Trinity Biotech, Ireland), the semiquantitative WST8/1-methoxy PMS (WST; Dojindo, Japan) and the Carestart G6PD Rapid Diagnostic Test (CSG; AccessBio, USA). Results were compared to spectrophotometry (Procedure 345, Trinity Biotech, Ireland). Sensitivity and specificity were calculated for each test with cut-off activities of 10%, 20%, 30% and 60% of the adjusted male median. Results The adjusted male median was 270.5 IU/1012 RBC. FST and WST were tested on 621 capillary blood samples, the CSG was tested on venous and capillary blood on 302 samples. At 30% G6PD activity, sensitivity for the FST was between 87.7% (95%CI: 76.8% to 93.9%) and 96.5% (95%CI: 87.9% to 99.5%) depending on definition of intermediate results; the WST was 84.2% (95%CI: 72.1% to 92.5%); and the CSG was between 68.8% (95%CI: 41.3% to 89.0%) and 93.8% (95%CI: 69.8% to 99.8%) when the test was performed on capillary or venous blood respectively. Sensitivity of FST and CSG (tested with venous blood) were comparable (p>0.05). The analysis of venous blood samples by the CSG yielded significantly higher results than FST and CSG performed on capillary blood (p<0.05). Sensitivity of the CSG varied depending on source of blood used (p<0.05). Conclusion The operational characteristics of the CSG were superior to all other test formats. Performance and operational characteristics of the CSG performed on venous blood suggest the test to be a good alternative to the FST. PMID:26849445

  19. NHEXAS PHASE I MARYLAND STUDY--PESTICIDES IN BLOOD ANALYTICAL RESULTS

    EPA Science Inventory

    The Pesticides in Blood Serum data set contains analytical results for measurements of up to 17 pesticides in 358 blood samples over 79 households. Each sample was collected via a venous sample from the primary respondent within each household by a phlebotomist. Samples were ge...

  20. Comparison of Minimally and More Invasive Methods of Determining Mixed Venous Oxygen Saturation.

    PubMed

    Smit, Marli; Levin, Andrew I; Coetzee, Johan F

    2016-04-01

    To investigate the accuracy of a minimally invasive, 2-step, lookup method for determining mixed venous oxygen saturation compared with conventional techniques. Single-center, prospective, nonrandomized, pilot study. Tertiary care hospital, university setting. Thirteen elective cardiac and vascular surgery patients. All participants received intra-arterial and pulmonary artery catheters. Minimally invasive oxygen consumption and cardiac output were measured using a metabolic module and lithium-calibrated arterial waveform analysis (LiDCO; LiDCO, London), respectively. For the minimally invasive method, Step 1 involved these minimally invasive measurements, and arterial oxygen content was entered into the Fick equation to calculate mixed venous oxygen content. Step 2 used an oxyhemoglobin curve spreadsheet to look up mixed venous oxygen saturation from the calculated mixed venous oxygen content. The conventional "invasive" technique used pulmonary artery intermittent thermodilution cardiac output, direct sampling of mixed venous and arterial blood, and the "reverse-Fick" method of calculating oxygen consumption. LiDCO overestimated thermodilution cardiac output by 26%. Pulmonary artery catheter-derived oxygen consumption underestimated metabolic module measurements by 27%. Mixed venous oxygen saturation differed between techniques; the calculated values underestimated the direct measurements by between 12% to 26.3%, this difference being statistically significant. The magnitude of the differences between the minimally invasive and invasive techniques was too great for the former to act as a surrogate of the latter and could adversely affect clinical decision making. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Techniques of adrenal venous sampling in patients with inferior vena cava or renal vein anomalies.

    PubMed

    Endo, Kenji; Morita, Satoru; Suzaki, Shingo; Yamazaki, Hiroshi; Nishina, Yu; Sakai, Shuji

    2018-06-01

    To review the techniques and technical success rate of adrenal venous sampling (AVS) in patients with inferior vena cava (IVC) or renal vein anomalies. The techniques and success rate of AVS in 15 patients with anomalies [8 with double IVC (dIVC), 3 with left IVC (ltIVC), 2 with retroaortic left renal vein (LRV), and 2 with circumaortic LRV] underwent AVS was retrospectively reviewed. Among 11 patients with IVC anomalies, the success rates for sampling the right and left adrenal veins (RAV and LAV) were 81.8 and 90.9%, respectively. In dIVC, the LAV was selected using the following four methods: approaching through the right IVC from the right femoral vein, flipping the LAV catheter tip in the LRV (n = 4) or the interiliac-communicating vein (n = 1), or through the ltIVC from the right (n = 1) or left (n = 2) femoral vein. Among the four patients with LRV anomalies, the success rate was 100% for each adrenal vein. AVS can be successfully performed in patients with anomalies. The key to technical success is understanding the venous anatomy based on pre-procedural CT images and choosing appropriate methods.

  2. NHEXAS PHASE I ARIZONA STUDY--METALS IN BLOOD ANALYTICAL RESULTS

    EPA Science Inventory

    The Metals in Blood data set contains analytical results for measurements of up to 2 metals in 165 blood samples over 165 households. Each sample was collected as a venous sample from the primary respondent within each household during Stage III of the NHEXAS study. The samples...

  3. NHEXAS PHASE I MARYLAND STUDY--METALS IN BLOOD ANALYTICAL RESULTS

    EPA Science Inventory

    The Metals in Blood data set contains analytical results for measurements of up to 2 metals in 374 blood samples over 80 households. Each sample was collected via a venous sample from the primary respondent within each household by a phlebotomist. Samples were generally drawn o...

  4. Evaluation of Marrow Perfusion in the Femoral Head by Dynamic Magnetic Resonance Imaging

    PubMed Central

    Tsukamoto, Hiroshi; Kang, Young S.; Jones, Lynne C.; Cova, Maria; Herold, Christian J.; McVeigh, Elliot; Hungerford, David S.; Zerhouni, Elias A.

    2007-01-01

    Rationale and Objectives There is a continuing need for a greater sensitivity of magnetic resonance imaging (MRI) in the diagnosis of avascular necrosis (AVN). Previously, it was demonstrated that a dynamic MRI method, with gadolinium-DTPA (Gd-DTPA) enhancement, can detect acute changes not seen on spin-echo images after arterial occlusion in a dog model. Because venous congestion appears to be a more directly relevant hemodynamic abnormality in a majority of clinical AVN cases, the authors extended the dynamic MRI technique to study changes in venous occlusion. Methods Dynamic MRI of the proximal femur was performed in five adult dogs before and after unilateral ligation of common iliac and lateral circumflex veins. Sixteen sequential gradient-recalled pulse sequence (GRASS) images (time resolution = 45 mseconds, echo time = 9 mseconds, flip angle = 65°) were obtained immediately after a bolus intravenous injection of 0.2 mmol/kg of Gd-DTPA. Simultaneous measurements of regional blood flow were made using the radioactive microsphere method. Results After venous ligation, there was a 25% to 45% decrease in the degree of enhancement compared with preligation values on the ligated side. The decrease in cumulative enhancement (integrated over the entire time course) was statistically significant. The occlusion technique was verified by confirming a statistically significant decrease in blood flow determined by the microsphere method. Conclusions Dynamic Gd-DTPA-enhanced fast MRI technique can detect acute changes in bone marrow perfusion due to venous occlusion. This technique may have applications in the early detection of nontraumatic AVN. PMID:1601616

  5. Evaluation of four rapid methods for hemoglobin screening of whole blood donors in mobile collection settings.

    PubMed

    Gómez-Simón, Antonia; Navarro-Núñez, Leyre; Pérez-Ceballos, Elena; Lozano, María L; Candela, María J; Cascales, Almudena; Martínez, Constantino; Corral, Javier; Vicente, Vicente; Rivera, José

    2007-06-01

    Predonation hemoglobin measurement is a problematic requirement in mobile donation settings, where accurate determination of venous hemoglobin by hematology analyzers is not available. We have evaluated hemoglobin screening in prospective donors by the semiquantitative copper sulphate test and by capillary blood samples analyzed by three portable photometers, HemoCue, STAT-Site MHgb, and the CompoLab HB system. Capillary blood samples were obtained from 380 donors and tested by the copper sulphate test and by at least one of the named portable photometers. Predonation venous hemoglobin was also determined in all donors using a Coulter Max-M analyzer. The three photometers provided acceptable reproducibility (CV below 5%), and displayed a significant correlation between the capillary blood samples and the venous hemoglobin (R2 0.5-0.8). HemoCue showed the best agreement with venous hemoglobin determination, followed by STAT-Site MHgb, and the CompoLab HB system. The copper sulphate test provided the highest rate of donors acceptance (83%) despite unacceptable hemoglobin levels, and the lowest rate for donor deferral (1%) despite acceptable hemoglobin levels. The percentage of donors correctly categorized for blood donation by the portable hemoglobinometers was 85%, 82%, and 76% for CompoLab HB system, HemoCue and STAT-Site, respectively. Our data suggest that hemoglobin determination remains a conflictive issue in donor selection in the mobile setting. Without appropriate performance control, capillary hemoglobin screening by either the copper sulphate method or by the novel portable hemoglobinometers could be inaccurate, thus potentially affecting both donor safety and the blood supply.

  6. Emergency medical technician-performed point-of-care blood analysis using the capillary blood obtained from skin puncture.

    PubMed

    Kim, Changsun; Kim, Hansol

    2017-12-09

    Comparing a point-of-care (POC) test using the capillary blood obtained from skin puncture with conventional laboratory tests. In this study, which was conducted at the emergency department of a tertiary care hospital in April-July 2017, 232 patients were enrolled, and three types of blood samples (capillary blood from skin puncture, arterial and venous blood from blood vessel puncture) were simultaneously collected. Each blood sample was analyzed using a POC analyzer (epoc® system, USA), an arterial blood gas analyzer (pHOx®Ultra, Nova biomedical, USA) and venous blood analyzers (AU5800, DxH2401, Beckman Coulter, USA). Twelve parameters were compared between the epoc and reference analyzers, with an equivalence test, Bland-Altman plot analysis and linear regression employed to show the agreement or correlation between the two methods. The pH, HCO 3 , Ca 2+ , Na + , K + , Cl - , glucose, Hb and Hct measured by the epoc were equivalent to the reference values (95% confidence interval of mean difference within the range of the agreement target) with clinically inconsequential mean differences and narrow limits of agreement. All of them, except pH, had clinically acceptable agreements between the two methods (results within target value ≥80%). Of the remaining three parameters (pCO 2, pO 2 and lactate), the epoc pCO 2 and lactate values were highly correlated with the reference device values, whereas pO 2 was not. (pCO 2 : R 2 =0.824, y=-1.411+0.877·x; lactate: R 2 =0.902, y=-0.544+0.966·x; pO 2 : R 2 =0.037, y=61.6+0.431·x). Most parameters, except only pO 2 , measured by the epoc were equivalent to or correlated with those from the reference method. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Effect of venous and lymphatic congestion on lymph capillary pressure of the skin in healthy volunteers and patients with lymph edema.

    PubMed

    Gretener, S B; Läuchli, S; Leu, A J; Koppensteiner, R; Franzeck, U K

    2000-01-01

    The aim of the present study was to assess the influence of venous and lymphatic congestion on lymph capillary pressure (LCP) in the skin of the foot dorsum of healthy volunteers and of patients with lymph edema. LCP was measured at the foot dorsum of 12 patients with lymph edema and 18 healthy volunteers using the servo-nulling technique. Glass micropipettes (7-9 microm) were inserted under microscopic control into lymphatic microvessels visualized by fluorescence microlymphography before and during venous congestion. Venous and lymphatic congestion was attained by cuff compression (50 mm Hg) at the thigh level. Simultaneously, the capillary filtration rate was measured using strain gauge plethysmography. The mean LCP in patients with lymph edema increased significantly (p < 0.05) during congestion (15.7 +/- 8.8 mm Hg) compared to the control value (12.2 +/- 8.9 mm Hg). The corresponding values of LCP in healthy volunteers were 4.3 +/- 2.6 mm Hg during congestion and 2.6 +/- 2.8 mm Hg during control conditions (p < 0.01). The mean increase in LCP in patients with lymph edema was 3.4 +/- 4.1 mm Hg, and 1.7 +/- 2.0 mm Hg in healthy volunteers (NS). The maximum spread of the lymph capillary network in patients increased from 13.9 +/- 6.8 mm before congestion to 18.8 +/- 8.2 mm during thigh compression (p < 0.05). No increase could be observed in healthy subjects. In summary, venous and lymphatic congestion by cuff compression at the thigh level results in a significant increase in LCP in healthy volunteers as well as in patients with lymph edema. The increased spread of the contrast medium in the superficial microlymphatics in lymph edema patients indicates a compensatory mechanism for lymphatic drainage during congestion of the veins and lymph collectors of the leg. Copyright 2000 S. Karger AG, Basel

  8. A randomized prospective long-term (>1 year) clinical trial comparing the efficacy and safety of radiofrequency ablation to 980 nm laser ablation of the great saphenous vein.

    PubMed

    Sydnor, Malcolm; Mavropoulos, John; Slobodnik, Natalia; Wolfe, Luke; Strife, Brian; Komorowski, Daniel

    2017-07-01

    Purpose To compare the short- and long-term (>1 year) efficacy and safety of radiofrequency ablation (ClosureFAST™) versus endovenous laser ablation (980 nm diode laser) for the treatment of superficial venous insufficiency of the great saphenous vein. Materials and methods Two hundred patients with superficial venous insufficiency of the great saphenous vein were randomized to receive either radiofrequency ablation or endovenous laser ablation (and simultaneous adjunctive therapies for surface varicosities when appropriate). Post-treatment sonographic and clinical assessment was conducted at one week, six weeks, and six months for closure, complications, and patient satisfaction. Clinical assessment of each patient was conducted at one year and then at yearly intervals for patient satisfaction. Results Post-procedure pain ( p < 0.0001) and objective post-procedure bruising ( p = 0.0114) were significantly lower in the radiofrequency ablation group. Improvements in venous clinical severity score were noted through six months in both groups (endovenous laser ablation 6.6 to 1; radiofrequency ablation 6.2 to 1) with no significant difference in venous clinical severity score ( p = 0.4066) or measured adverse effects; 89 endovenous laser ablation and 87 radiofrequency patients were interviewed at least 12 months out with a mean long-term follow-up of 44 and 42 months ( p = 0.1096), respectively. There were four treatment failures in each group, and every case was correctable with further treatment. Overall, there were no significant differences with regard to patient satisfaction between radiofrequency ablation and endovenous laser ablation ( p = 0.3009). There were no cases of deep venous thrombosis in either group at any time during this study. Conclusions Radiofrequency ablation and endovenous laser ablation are highly effective and safe from both anatomic and clinical standpoints over a multi-year period and neither modality achieved superiority over the other.

  9. Variability in alignment of central venous pressure transducer to physiologic reference point in the intensive care unit-A descriptive and correlational study.

    PubMed

    Sjödin, Carl; Sondergaard, Soren; Johansson, Lotta

    2018-06-01

    The phlebostatic axis is the most commonly used anatomical external reference point for central venous pressure measurements. Deviation in the central venous pressure transducer alignment from the phlebostatic axis causes inadequate pressure readings, which may affect treatment decisions for critically ill patients in intensive care units. The primary aim of the study was to assess the variability in central venous pressure transducer levelling in the intensive care unit. We also assessed whether patient characteristics impacted on central venous pressure transducer alignment deviation. A sample of 61 critical care nurses was recruited and asked to place a transducer at the appropriate level for central venous pressure measurement. The measurements were performed in the intensive care unit on critically ill patients in supine and Fowler's positions. The variability among the participants using eyeball levelling and a laser levelling device was calculated in both sessions and adjusted for patient characteristics. A significant variation was found among critical care nurses in the horizontal levelling of the pressure transducer placement when measuring central venous pressure in the intensive care unit. Using a laser levelling device did not reduce the deviation from the phlebostatic axis. Patient characteristics had little impact on the deviation in the measurements. The anatomical external landmark for the phlebostatic axis varied between critical care nurses, as the variation in the central venous pressure transducer placement was not reduced with a laser levelling device. Standardisation of a zero-level for vascular pressures should be considered to reduce the variability in vascular pressure readings in the intensive care unit to improve patient treatment decisions. Further studies are needed to evaluate critical care nurses' knowledge and use of central venous pressure monitoring and whether assistive tools and/or routines can improve the accuracy in vascular pressure measurements in intensive care units. Copyright © 2018 Australian College of Critical Care Nurses Ltd. Published by Elsevier Ltd. All rights reserved.

  10. The correlation analysis of tumor necrosis factor-alpha-308G/A polymorphism and venous thromboembolism risk: A meta-analysis.

    PubMed

    Gao, Quangen; Zhang, Peijin; Wang, Wei; Ma, He; Tong, Yue; Zhang, Jing; Lu, Zhaojun

    2016-10-01

    Venous thromboembolism is a common complex disorder, being the resultant of gene-gene and gene-environment interactions. Tumor necrosis factor-alpha is a proinflammatory cytokine which has been implicated in venous thromboembolism risk. A promoter 308G/A polymorphism in the tumor necrosis factor-alpha gene has been suggested to modulate the risk for venous thromboembolism. However, the published findings remain inconsistent. In this study, we conducted a meta-analysis of all available data regarding this issue. Eligible studies were identified through search of Pubmed, EBSCO Medline, Web of Science, and China National Knowledge Infrastructure (CNKI, Chinese) databases up to June 2014. Pooled Odd ratios (ORs) with 95% confidence intervals were applied to estimating the strength of the genetic association in the random-effects model or fixed-effects model. A total of 10 studies involving 1999 venous thromboembolism cases and 2166 controls were included in this meta-analysis to evaluate the association between tumor necrosis factor-alpha-308G/A polymorphism and venous thromboembolism risk. Overall, no significantly increased risk venous thromboembolism was observed in all comparison models when all studies were pooled into the meta-analysis. However, in stratified analyses by ethnicity, there was a pronounced association with venous thromboembolism risk among West Asians in three genetic models (A vs. G: OR = 1.82, 95%CI = 1.13-2.94; GA vs. GG: OR = 1.82, 95%CI = 1.08-3.06; AA/GA vs. GG: OR = 1.88, 95%CI = 1.12-3.16). When stratifying by source of controls, no significant result was detected in all genetic models. This meta-analysis demonstrates that tumor necrosis factor-alpha 308G/A polymorphism may contribute to susceptibility to venous thromboembolism among West Asians. Studies are needed to ascertain these findings in larger samples and different racial groups. © The Author(s) 2015.

  11. A comparison of capillary and venous blood haematocrits of pregnant women in Nigeria: the impact on diagnosis and prevalence of anaemia in pregnancy.

    PubMed

    Dim, Cyril Chukwudi; Ugwu, Emmanuel Onyebuchi; Anyaehie, Ugochukwu Bond; Obioha, Kingsley Chukwu

    2014-01-01

    Volume of red cells in capillary blood varies from that of venous blood. The magnitude of this variation as well as its impact on the diagnosis of anaemia in pregnancy needs to be studied. This study demonstrates the disparity between capillary and venous PCV in pregnancy. To determine whether capillary blood PCV (cPCV) differed from venous blood PCV (vPCV) of normal pregnant women in Enugu, Nigeria, and its effect on diagnosis and prevalence of anaemia. PCV was estimated using pairs of venous and capillary blood samples from 200 consecutive pregnant women at the Antenatal Clinic of University of Nigeria Teaching Hospital, Enugu, Nigeria. Participants' cPCV (median = 34.0%, IQR = 31.0-35.8) was significantly lower than their vPCV (median = 34.0%, IQR = 32.0-37.0) (Z = -6.85, P < 0.001). However, women's cPCV had strong positive correlation with their vPCV (r = 0.883, P < 0.001). The prevalence of anaemia among participants using capillary and venous blood was 33.5% (67/200) and 28.0% (56/200), respectively (O.R = 1.3 (CI 95%: 0.85, 1.98),  P = 0.233). Capillary blood PCV was lower than vPCV among pregnant women in Enugu, Nigeria. Nevertheless, the prevalence of anaemia derived from cPCV did not differ significantly from that of vPCV.

  12. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--METALS IN BLOOD ANALYTICAL RESULTS

    EPA Science Inventory

    The Metals in Blood data set contains analytical results for measurements of up to 2 metals in 86 blood samples over 86 households. Each sample was collected as a venous sample from the primary respondent within each household. The samples consisted of two 3-mL tubes. The prim...

  13. Reliability of blood color and blood gases in discriminating arterial from venous puncture during cardiopulmonary resuscitation.

    PubMed

    Park, Je Sung; Lee, Byung Kook; Jeung, Kyung Woon; Choi, Sung Soo; Park, Sang Wook; Song, Kyung Hwan; Lee, Sung Min; Heo, Tag; Min, Yong Il

    2015-04-01

    We investigated the use of blood color brightness and blood gas variables for discriminating arterial from venous puncture during cardiopulmonary resuscitation (CPR). The study's aims were to determine if discrimination using Po2 is superior to using blood color brightness, and if blood color brightness, Po2, and acid-base variables derived from blood gas analysis accurately discriminate arterial from venous blood during CPR. Fifteen pigs underwent ventricular fibrillation followed by CPR. During CPR, paired femoral arterial and venous blood samples were obtained, and 2 blinded observers were asked to identify the blood's origin. Blood color brightness was measured using a blood brightness scale (BBS). The discriminatory performances of the BBS and blood gas variables were evaluated by calculating the area under receiver operating characteristic curves (AUC). The observers accurately discriminated arterial from venous blood with a sensitivity of 97.0% (84.7%-99.5%) and specificity of 84.9% (69.1%-93.4%). The BBS (AUC = 0.983) and Po2 (AUC = 0.981) methods both showed comparable and excellent discriminatory performances. pH, Pco2, and HCO3(-) all discriminated arterial from venous blood (AUC = 0.831, 0.971, and 0.652, respectively). The AUC for Pco2 was comparable to that for Po2 but significantly larger than that for pH (P = .002) or HCO3(-) (P < .001). The BBS and Po2 methods showed comparable and excellent discrimination performances. Using pH, Pco2, and HCO3(-) levels also discriminated arterial from venous blood during CPR with statistical significance. Copyright © 2015 Elsevier Inc. All rights reserved.

  14. Decompression from Saturation Using Oxygen: Its Effect on DCS and RNA in Large Swine

    DTIC Science & Technology

    2010-01-01

    mask. The external jugular vein was catheter- ized with a 14-Ga., 30-cm single lumen catheter ( Central Venous Catheterization Set; Arrow... venous catheterization for sequential blood sampling from the pig. J Invest Surg 1991; 4:103-7. 3. Behnke AR. The isobaric (oxygen window) principle of...pressures may lead to toxicity that involves the pulmonary system and/ or the central nervous system (CNS). There is evidence that 100% oxygen in

  15. The accuracy of home glucose meters in hypoglycemia.

    PubMed

    Sonmez, Alper; Yilmaz, Zeynep; Uckaya, Gokhan; Kilic, Selim; Tapan, Serkan; Taslipinar, Abdullah; Aydogdu, Aydogan; Yazici, Mahmut; Yilmaz, Mahmut Ilker; Serdar, Muhittin; Erbil, M Kemal; Kutlu, Mustafa

    2010-08-01

    Home glucose meters (HGMs) may not be accurate enough to sense hypoglycemia. We evaluated the accuracy and the capillary and venous comparability of five different HGMs (Optium Xceed [Abbott Diabetes Care, Alameda, CA, USA], Contour TS [Bayer Diabetes Care, Basel, Switzerland], Accu-Chek Go [Roche Ltd., Basel, Switzerland], OneTouch Select [Lifescan, Milpitas, CA, USA], and EZ Smart [Tyson Bioresearch Inc., Chu-Nan, Taiwan]) in an adult population. The insulin hypoglycemia test was performed to 59 subjects (56 males; 23.6 +/- 3.2 years old). Glucose was measured from forearm venous blood and finger capillary samples both before and after regular insulin (0.1 U/kg) was injected. Venous samples were analyzed in the reference laboratory by the hexokinase method. In vitro tests for method comparison and precision analyses were also performed by spiking the glucose-depleted venous blood. All HGMs failed to sense hypoglycemia to some extend. EZ Smart was significantly inferior in critical error Zone D, and OneTouch Select was significantly inferior in the clinically unimportant error Zone B. Accu-Chek Go, Optium Xceed, and Contour TS had similar performances and were significantly better than the other two HGMs according to error grid analysis or International Organization for Standardization criteria. The in vitro tests were consistent with the above clinical data. The capillary and venous consistencies of Accu-Chek Go and OneTouch Select were better than the other HGMs. The present results show that not all the HGMs are accurate enough in low blood glucose levels. The patients and the caregivers should be aware of these restrictions of the HGMs and give more credit to the symptoms of hypoglycemia than the values obtained by the HGMs. Finally, these results indicate that there is a need for the revision of the accuracy standards of HGMs in low blood glucose levels.

  16. Do the venous blood samples replicate malaria parasite densities found in capillary blood? A field study performed in naturally-infected asymptomatic children in Cameroon.

    PubMed

    Sandeu, Maurice M; Bayibéki, Albert N; Tchioffo, Majoline T; Abate, Luc; Gimonneau, Geoffrey; Awono-Ambéné, Parfait H; Nsango, Sandrine E; Diallo, Diadier; Berry, Antoine; Texier, Gaétan; Morlais, Isabelle

    2017-08-17

    The measure of new drug- or vaccine-based approaches for malaria control is based on direct membrane feeding assays (DMFAs) where gametocyte-infected blood samples are offered to mosquitoes through an artificial feeder system. Gametocyte donors are identified by the microscopic detection and quantification of malaria blood stages on blood films prepared using either capillary or venous blood. However, parasites are known to sequester in the microvasculature and this phenomenon may alter accurate detection of parasites in blood films. The blood source may then impact the success of mosquito feeding experiments and investigations are needed for the implementation of DMFAs under natural conditions. Thick blood smears were prepared from blood obtained from asymptomatic children attending primary schools in the vicinity of Mfou (Cameroon) over four transmission seasons. Parasite densities were determined microscopically from capillary and venous blood for 137 naturally-infected gametocyte carriers. The effect of the blood source on gametocyte and asexual stage densities was then assessed by fitting cumulative link mixed models (CLMM). DMFAs were performed to compare the infectiousness of gametocytes from the different blood sources to mosquitoes. Prevalence of Plasmodium falciparum asexual stages among asymptomatic children aged from 4 to 15 years was 51.8% (2116/4087). The overall prevalence of P. falciparum gametocyte carriage was 8.9% and varied from one school to another. No difference in the density of gametocyte and asexual stages was found between capillary and venous blood. Attempts to perform DMFAs with capillary blood failed. Plasmodium falciparum malaria parasite densities do not differ between capillary and venous blood in asymptomatic subjects for both gametocyte and trophozoite stages. This finding suggests that the blood source should not interfere with transmission efficiency in DMFAs.

  17. NHEXAS PHASE I MARYLAND STUDY--LIPIDS IN BLOOD ANALYTICAL RESULTS

    EPA Science Inventory

    The Lipids in Blood data set presents concentrations of cholesterol and total triglycerides in blood serum. The data set presents measurements for up to 2 lipids in 358 blood samples over 79 households. Each sample was collected via a venous sample from the primary respondent w...

  18. Plasma lactate concentrations and blood gas values in dogs undergoing surgical attenuation of a single congenital portosystemic shunt.

    PubMed

    Cariou, M P; Lipscomb, V J; Hughes, D; Brodbelt, D; Brockman, D J

    2009-08-22

    Plasma concentration of lactate and the values of pH, pO(2) and pCO(2) were measured in the portal, systemic venous and, when possible, systemic arterial blood of 31 dogs with a single congenital portosystemic shunt, before and shortly after the temporary complete occlusion of the shunt, and at the end of surgery. At completion of the surgery, the shunt in 16 of the dogs had been occluded completely whereas in the other 15 it had been occluded only partially. There were no significant differences between any of the measurements of these variables in the portal venous, systemic venous or arterial plasma of any of the dogs, or between the values measured in the groups in which the shunts had been occluded completely or partially. Furthermore, there were no significant differences between the two groups of dogs in the arteriovenous gradients calculated at any of the sampling sites or sampling times. None of the variables was associated with the development of postoperative complications.

  19. Comparison of intraosseous and infiltration injections for venous lidocaine blood concentrations and heart rate changes after injection of 2% lidocaine with 1:100,000 epinephrine.

    PubMed

    Wood, Mark; Reader, Al; Nusstein, John; Beck, Mike; Padgett, David; Weaver, Joel

    2005-06-01

    The purpose of this prospective, randomized study was to compare the venous blood levels of lidocaine and heart rate changes after intraosseous and infiltration injections of 1.8 ml of 2% lidocaine with 1:100,000 epinephrine. Using a crossover design, 20 subjects randomly received an intraosseous and infiltration injection at two separate appointments. The heart rate was measured using a pulse oximeter. Venous blood samples were collected before the injections and at 2, 5, 10, 15, 20, 25, 30, 45, and 60 min after the injections. The blinded plasma samples were analyzed for lidocaine concentrations using high-performance liquid chromatography (HPLC). The intraosseous injection resulted in a statistically significant increase in heart rate, when compared to the infiltration injection, during solution deposition and for 2 min after the injection. The plasma levels of lidocaine were not statistically different for maxillary anterior intraosseous and infiltration injections when using 1.8 ml of 2% lidocaine with 1:100,000 epinephrine.

  20. Arterio-venous anastomoses in the human skin and their role in temperature control

    PubMed Central

    Walløe, Lars

    2016-01-01

    ABSTRACT Arterio-venous anastomoses (AVAs) are direct connections between small arteries and small veins. In humans they are numerous in the glabrous skin of the hands and feet. The AVAs are short vessel segments with a large inner diameter and a very thick muscular wall. They are densely innervated by adrenergic axons. When they are open, they provide a low-resistance connection between arteries and veins, shunting blood directly into the venous plexuses of the limbs. The AVAs play an important role in temperature regulation in humans in their thermoneutral zone, which for a naked resting human is about 26°C to 36°C, but lower when active and clothed. From the temperature control center in the hypothalamus, bursts of nerve impulses are sent simultaneously to all AVAs. The AVAs are all closed near the lower end and all open near the upper end of the thermoneutral zone. The small veins in the skin of the arms and legs are also contracted near the lower end of the thermoneutral zone and relax to a wider cross section as the ambient temperature rises. At the cold end of the thermoneutral range, the blood returns to the heart through the deep veins and cools the arterial blood through a countercurrent mechanism. As the ambient temperature rises, more blood is returned through the superficial venous plexuses and veins and heats the skin surface of the full length of the 4 limbs. This skin surface is responsible for a large part of the loss of heat from the body toward the upper end of the thermoneutral zone. PMID:27227081

  1. Catheter interventional treatment of congenital portosystemic venous shunts in childhood.

    PubMed

    Knirsch, Walter; Benz, Dominik C; Bühr, Patrick; Quandt, Daniel; Weber, Roland; Kellenberger, Christian; Braegger, Christian P; Kretschmar, Oliver

    2016-06-01

    The study aimed on the catheter interventional treatment of congenital portosystemic venous shunt (CPSVS) in childhood and the impact on vascular growth of hypoplastic portal veins. Clinical course and follow up of partial or complete closure of CPSVS are described. CPSVS is a very rare vascular malformation of the portal venous drainage resulting in potentially life threatening abdominal, pulmonary, cerebral, and cardiac complications. The anatomic type, clinical course, and diagnosis must be determined for optimal management. Single centre case series. Eight (6 female) children with extrahepatic (n = 5) and intrahepatic (n = 3) CPSVS were diagnosed invasively by catheterization, including test balloon occlusion of the shunt and simultaneous retrograde angiography, and treated by catheter interventions (n = 5) with partial (n = 2) and complete (n = 3) occlusion of CPSVS at a median age of 3.9 years (range 0.7-21). Congenital heart disease (CHD) was the most frequent associated organ manifestation (n = 5) followed by mild to severe pulmonary arterial hypertension (n = 4), hepatopulmonary syndrome (n = 2), and portosystemic encephalopathy (n = 1). CHD was simple (n = 3) or complex type (n = 2). Three patients were untreated so far, because they were in excellent clinical condition at an age <1 year, refused treatment, or planned for later treatment. Accurate invasive diagnosis of CPSVS with test balloon occlusion of the shunt is mandatory to depict the anatomic situation. Catheter interventional treatment of CPSVS offers a feasible and safe approach with complete or partial closure of the vascular malformation inducing potentially significant vascular growth of a former hypoplastic portal venous system. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  2. Renal and femoral venous blood flows are regulated by different mechanisms dependent on α-adrenergic receptor subtypes and nitric oxide in anesthetized rats.

    PubMed

    Fioretti, Alexandre C; Ogihara, Cristiana A; Cafarchio, Eduardo M; Venancio, Daniel P; de Almeida, Roberto Lopes; Antonio, Bruno B; Sato, Monica A

    2017-12-01

    Venous and arterial walls are responsive to sympathetic system and circulating substances, nevertheless, very few is known about the venous blood flow regulation simultaneously to arterial vascular beds. In this study, we compared the venous and arterial blood flow regulation in visceral and muscular beds upon injection of different doses of vasoactive drugs which act in arterial vascular beds. Anesthetized adult male Wistar rats underwent to right femoral artery and vein cannulation for hemodynamic recordings and infusion of drugs. Doppler flow probes were placed around the left renal artery and vein, and left femoral artery and vein to evaluate the changes in flood flow. Phenylephrine (PHE) injection (α 1 -adrenergic receptor agonist) elicited vasoconstriction in all arteries and veins. Intravenous prazosin (PZS) (1mg/kg, α 1 -adrenergic receptor blocker) caused renal artery vasodilation, but not in the other beds. Vasoconstrictor effect of PHE was abolished by PZS in all vascular beds, except in femoral vein. Phentolamine (PTL) injection (1mg/kg, α 1 /α 2 -adrenergic receptor blocker) produced renal artery vasodilation with no change in other beds. After PTL, the vasoconstriction evoked by PHE was abolished in all vascular beds. Sodium Nitroprusside (SNP), a nitric oxide donor, elicited vasodilation in all beds, and after PTL but not post PZS injection, SNP enhanced the vasodilatory effect in femoral vein. Our findings suggest that the vasoconstriction in renal and femoral veins is mediated by different subtypes of α-adrenoceptors. The nitric oxide-dependent vasodilation in femoral vein enhances when α 2 -adrenoceptors are not under stimulation, but not in the other vascular beds investigated. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY-PESTICIDES AND POLYCHLORINATED BIPHENYLS (PCBS) IN BLOOD ANALYTICAL RESULTS

    EPA Science Inventory

    The Pesticides and PCBs in Blood data set contains analytical results for measurements of up to 11 pesticides and up to 36 PCBs in 86 blood samples over 86 households. Each sample was collected as a venous sample from the primary respondent within each household. The samples co...

  4. Mesenteric-portal axis thrombosis and deep venous thrombosis in a patient with inferior vena cava agenesis.

    PubMed

    Lluis Pons, Laia; Chahri Vizcarro, Nadia; Llaverias Borrell, Silvia; Miquel Abbad, Carlos

    2017-06-01

    Splenoportal axis thrombosis not associated with cirrhosis or neoplasms has a prevalence lower than 5 per 10,000 people. An etiologic factor responsible for portal thrombosis is finally identified in most cases, usually systemic thrombogenic factors or predisposing local factors. However, despite a detailed study of all etiologic factors, up to 30% of cases are eventually considered as idiopathic in origin. We report the case of a 41-year-old patient who presented with abdominal pain and lower extremity edema. The patient was diagnosed with portal and mesenteric-portal confluence thrombosis, bilateral deep venous thrombosis and right lumbar vein thrombosis based on an abdominal CT scan. This was associated with a likely congenital inferior vena cava agenesis. This malformation is present in approximately 5% of patients with deep vein thrombosis even though it represents a rare cause of portal thrombosis. The fact that several thromboses developed simultaneously makes this a unique and isolated case in the current literature as no similar cases have been reported thus far.

  5. Laparoscopic umbilical hernia repair in a cirrhotic patient with a peritoneovenous shunt.

    PubMed

    Umemura, Akira; Suto, Takayuki; Sasaki, Akira; Fujita, Tomohiro; Endo, Fumitaka; Wakabayashi, Go

    2015-05-01

    A 62-year-old Japanese woman who had developed massive cirrhotic ascites was referred to our hospital for a peritoneovenous shunt implant. However, CT examination revealed an umbilical hernia that had not been observed before the peritoneovenous shunt was implanted. We decided to perform laparoscopic umbilical hernia repair to keep carbon dioxide from flowing backward into the central circulatory system. We first clamped the catheter and set the upper limit of the pneumoperitoneum pressure to 6 mmHg. The central venous pressure was also measured simultaneously. Mesh was then applied over the hernia and fixed by the double-crown technique. Finally, 1000-mL physiological saline was infused into the abdominal cavity while the pneumoperitoneum was slowly released. In this case, we safely performed laparoscopic umbilical hernia repair while making some alterations, specifically catheter clamping, reducing pneumoperitoneum pressure, monitoring central venous pressure, and infusing physiological saline. © 2014 Japan Society for Endoscopic Surgery, Asia Endosurgery Task Force and Wiley Publishing Asia Pty Ltd.

  6. Blood oxygen binding in hypoxaemic calves.

    PubMed

    Cambier, Carole; Clerbaux, Thierry; Detry, Bruno; Marville, Vincent; Frans, Albert; Gustin, Pascal

    2002-01-01

    Blood oxygen transport and tissue oxygenation were studied in 28 calves from the Belgian White and Blue breed (20 healthy and 8 hypoxaemic ones). Hypoxaemic calves were selected according to their high respiratory frequency and to their low partial oxygen pressure (PaO2) in the arterial blood. Venous and arterial blood samples were collected, and 2,3-diphosphoglycerate, adenosine triphosphate, chloride, inorganic phosphate and hemoglobin concentrations, and pH, PCO, and PO2 were determined. An oxygen equilibrium curve (OEC) was measured in standard conditions, for each animal. The arterial and venous OEC were calculated, taking body temperature, pH and PCO2 values in arterial and venous blood into account. The oxygen exchange fraction (OEF%), corresponding to the degree of blood desaturation between the arterial and the venous compartments, and the amount of oxygen released at the tissue level by 100 mL of blood (OEF Vol%) were calculated from the arterial and venous OEC combined with the PO2 and hemoglobin concentration. In hypoxaemic calves investigated in this study, the hemoglobin oxygen affinity, measured under standard conditions, was not modified. On the contrary, in vivo acidosis and hypercapnia induced a decrease in the hemoglobin oxygen affinity in arterial blood, which combined to the decrease in PaO2 led to a reduced hemoglobin saturation degree in the arterial compartment. However, this did not impair the oxygen exchange fraction (OEF%), since the hemoglobin saturation degree in venous blood was also diminished.

  7. [Port device central venous access in children with chronic renal disease--personal experience].

    PubMed

    Szczepańska, Maria; Szprynger, Krystyna; Stoksik, Piotr; Morawiec-Knysak, Aurelia; Adamczyk, Piotr; Ziora, Katarzyna; Oswiecimska, Joanna

    2006-01-01

    The application of central venous lines in children has been widely accepted in the case of pediatric cancer treatment. This is of particular importance when the treatment must be continued during the long period of time. The indication to long-term application of central venous lines became significantly frequent within last years. They are necessary in the treatment of chronic pediatric patients, in whom the central venous line allows continuous access for medication, parenteral rehydration, nutrition and frequent blood sampling. In the current study authors present their experience in subcutaneous port devices application in children with kidney disease. The case history data obtained from 8 children were retrospectively analysed. In these children subcutaneous port devices were applied for mean 26.7 months (totally 9 port devices). The mean age at the time of implantation was 2.2 years, and the mean body weight--10.6 kg. Peripheral venous access in all children was bad. In one child during the time of implantation the hematoma of coli and chest was present. Infectious complications connected with implanted port device were not detected. Thrombotic complications were present in 6 children with chronic renal failure--in 5 the lumen of port device has been successfully recanalysed, in 3 cases even several times. In 1 child the thrombus on the tip of central venous line was detected. In 2 children the removal of port device was necessary because of breakage of venous line and in the second case because of port device thrombosis. Two children died with functioning port device. The cause of death was not connected with implanted port device. The application of subcutaneous port devices definitely improved the comfort of treatment but was significantly associated with thrombotic complications. Infectious complications were not detected as compared to hematological group of patients.

  8. Biomarkers of low-grade inflammation in primary varicose veins of the lower limbs.

    PubMed

    Flore, R; Ponziani, F R; Gerardino, L; Santoliquido, A; Di Giorgio, A; Lupascu, A; Nesci, A; Tondi, P

    2015-02-01

    To analyze serum biomarkers of CVD in selected patients with primary axial reflux of great saphenous vein in one or both lower limbs. Ninety-six patients affected by uncomplicated varicose veins, were enrolled in the study. A unilateral, primary axial reflux in great saphenous veins was detected in 54 patients (U-CVD group) and a bilateral one in 42 (B-CVD group). Sixty-five age and sex-matched subjects without venous reflux were enrolled as controls. Mean venous pressure of both lower limbs at the distal great saphenous vein (mGSVP) and venous reflux were measured by continuous-wave Doppler ultrasound and echoduplex scanning, respectively. Reactive Oxygen Species (ROS), tissue Plasminogen Activator (t-PA) and its Inhibitor 1 (PAI-1) activities, Hematocrit (HTC), White Blood Cells (WBC), Neutrophyls (NEU), Platelets (PLT), Fibrinogen (FIB) and Blood Viscosity (BV) were assessed in blood samples drawn from the antecubital vein. B-CVD group showed higher fibrinogen values (p < 0.005) and higher mean venous pressure (0 < 0.0001) in comparison to controls, while U-CVD did not. No difference was found between both groups and controls for all the other parameters. Increased fibrinogen levels in patients with bilateral varicose veins may represent an early warning signal, as it could be associated to the long-term progression of chronic venous disease.

  9. Whole blood flow cytometry measurements of in vivo platelet activation in critically-Ill patients are influenced by variability in blood sampling techniques.

    PubMed

    Rondina, Matthew T; Grissom, Colin K; Men, Shaohua; Harris, Estelle S; Schwertz, Hansjorg; Zimmerman, Guy A; Weyrich, Andrew S

    2012-06-01

    Flow cytometry is often used to measure in vivo platelet activation in critically-ill patients. Variability in blood sampling techniques, which may confound these measurements, remains poorly characterized. Platelet activation was measured by flow cytometry performed on arterial and venous blood from 116 critically-ill patients. We determined how variability in vascular sampling site, processing times, and platelet counts influenced levels of platelet-monocyte aggregates (PMA), PAC-1 binding (for glycoprotein (GP) IIbIIIa), and P-selectin (P-SEL) expression. Levels of PMA, but not PAC-1 binding or P-SEL expression, were significantly affected by variability in vascular sampling site. Average PMA levels were approximately 60% higher in whole blood drawn from an arterial vessel compared to venous blood (16.2±1.8% vs. 10.7±1.2%, p<0.05). Levels of PMA in both arterial and venous blood increased significantly during ex vivo processing delays (1.7% increase for every 10 minute delay, p<0.05). In contrast, PAC-1 binding and P-SEL expression were unaffected by processing delays. Levels of PMA, but not PAC-1 binding or P-SEL expression, were correlated with platelet count quartiles (9.4±1.6% for the lowest quartile versus 15.4±1.6% for the highest quartile, p<0.05). In critically-ill patients, variability in vascular sampling site, processing times, and platelet counts influence levels of PMA, but not PAC-1 binding or P-SEL expression. These data demonstrate the need for rigorous adherence to blood sampling protocols, particularly when levels of PMA, which are most sensitive to variations in blood collection, are measured for detection of in vivo platelet activation. Copyright © 2011 Elsevier Ltd. All rights reserved.

  10. Calibration in dogs of a subcutaneous miniaturized glucose sensor using a glucose meter for blood glucose determination.

    PubMed

    Poitout, V; Moatti-Sirat, D; Reach, G

    1992-01-01

    The feasibility of calibrating a glucose sensor by using a wearable glucose meter for blood glucose determination and moderate variations of blood glucose concentration was assessed. Six miniaturized glucose sensors were implanted in the subcutaneous tissue of conscious dogs, and the parameters used for the in vivo calibration of the sensor (sensitivity coefficient and extrapolated current in the absence of glucose) were determined from values of blood glucose and sensor response obtained during glucose infusion. (1) Venous plasma glucose level and venous total blood glucose level were measured simultaneously on the same sample, using a Beckman analyser and a Glucometer II, respectively. The regression between plasma glucose (x) and whole blood glucose (y) was y = 1.12x-0.08 mM (n = 114 values, r = 0.96, p = 0.0001). The error grid analysis indicated that the use of a Glucometer II for blood glucose determination was appropriate in dogs. (2) The in vivo sensitivity coefficients were 0.57 +/- 0.11 nA mM-1 when determined from plasma glucose, and 0.51 +/- 0.07 nA mM-1 when determined from whole blood glucose (t = 1.53, p = 0.18, n.s.). The background currents were 0.88 +/- 0.57 nA when determined from plasma glucose, and 0.63 +/- 0.77 nA when determined from whole blood glucose (t = 0.82, p = 0.45, n.s.). (3) The regression equation of the estimation of the subcutaneous glucose level obtained from the two methods was y = 1.04x + 0.56 mM (n = 171 values, r = 0.98, p = 0.0001).(ABSTRACT TRUNCATED AT 250 WORDS)

  11. Surgical model pig ex vivo for venous dissection teaching in medical schools.

    PubMed

    Tube, Milton Ignacio Carvalho; Spencer-Netto, Fernando Antonio Campelo; Oliveira, Anderson Igor Pereira de; Holanda, Arthur Cesário de; Barros, Bruno Leão Dos Santos; Rezende, Caio Cezar Gomes; Cavalcanti, João Pedro Guerra; Batista, Marília Apolinário; Campos, Josemberg Marins

    2017-02-01

    To investigate a method for development of surgical skills in medical students simulating venous dissection in surgical ex vivo pig model. Prospective, analytical, experimental, controlled study with four stages: selection, theoretical teaching, training and assessment. Sample of 312 students was divided into two groups: Group A - 2nd semester students; Group B - students of 8th semester. The groups were divided into five groups of 12 students, trained two hours per week in the semester. They set up four models to three students in each skill station assisted by a monitor. Teaching protocol emergency procedures training were applied to venous dissection, test goal-discursive and OSATS scale. The pre-test confirmed that the methodology has not been previously applied to the students. The averages obtained in the theoretical evaluation reached satisfactory parameters in both groups. The results of applying OSATS scale showed the best performance in group A compared to group B, however, both groups had satisfactory medium. The method was enough to raise a satisfactory level of skill both groups in venous dissection running on surgical swine ex vivo models.

  12. Pulmonary Effects of Eight-Hour MK 16 MOD 1 Dives

    DTIC Science & Technology

    2007-10-01

    carboxyhemoglobin and hemoglobin concentrations,5 and the samples were chosen to ensure that the analyzer signal was stable when measurements were recorded.6...Lexington, MA) determined the pretest carboxyhemoglobin and hemoglobin concentrations from a venous blood sample. An autorefractor (Humphrey model 599

  13. Four-Hour Dives with Exercise While Breathing Oxygen Partial Pressure of 1.3 ATM

    DTIC Science & Technology

    2006-09-01

    carboxyhemoglobin and hemoglobin concentrations, 8 and the samples were chosen to ensure that the analyzer signal was stable when measurements were...Instrumentation Laboratory; Lexington, MA) determined the pretest carboxyhemoglobin and hemoglobin concentrations from a venous blood sample. An autorefractor

  14. Bilateral inferior petrosal sinus sampling

    PubMed Central

    Grossrubatscher, Erika; Dalino Ciaramella, Paolo; Boccardi, Edoardo

    2016-01-01

    Simultaneous bilateral inferior petrosal sinus sampling (BIPSS) plays a crucial role in the diagnostic work-up of Cushing’s syndrome. It is the most accurate procedure in the differential diagnosis of hypercortisolism of pituitary or ectopic origin, as compared with clinical, biochemical and imaging analyses, with a sensitivity and specificity of 88–100% and 67–100%, respectively. In the setting of hypercortisolemia, ACTH levels obtained from venous drainage of the pituitary are expected to be higher than the levels of peripheral blood, thus suggesting pituitary ACTH excess as the cause of hypercortisolism. Direct stimulation of the pituitary corticotroph with corticotrophin-releasing hormone enhances the sensitivity of the procedure. The procedure must be undertaken in the presence of hypercortisolemia, which suppresses both the basal and stimulated secretory activity of normal corticotrophic cells: ACTH measured in the sinus is, therefore, the result of the secretory activity of the tumor tissue. The poor accuracy in lateralization of BIPSS (positive predictive value of 50–70%) makes interpetrosal ACTH gradient alone not sufficient for the localization of the tumor. An accurate exploration of the gland is recommended if a tumor is not found in the predicted area. Despite the fact that BIPSS is an invasive procedure, the occurrence of adverse events is extremely rare, particularly if it is performed by experienced operators in referral centres. PMID:27352844

  15. Bilateral inferior petrosal sinus sampling.

    PubMed

    Zampetti, Benedetta; Grossrubatscher, Erika; Dalino Ciaramella, Paolo; Boccardi, Edoardo; Loli, Paola

    2016-07-01

    Simultaneous bilateral inferior petrosal sinus sampling (BIPSS) plays a crucial role in the diagnostic work-up of Cushing's syndrome. It is the most accurate procedure in the differential diagnosis of hypercortisolism of pituitary or ectopic origin, as compared with clinical, biochemical and imaging analyses, with a sensitivity and specificity of 88-100% and 67-100%, respectively. In the setting of hypercortisolemia, ACTH levels obtained from venous drainage of the pituitary are expected to be higher than the levels of peripheral blood, thus suggesting pituitary ACTH excess as the cause of hypercortisolism. Direct stimulation of the pituitary corticotroph with corticotrophin-releasing hormone enhances the sensitivity of the procedure. The procedure must be undertaken in the presence of hypercortisolemia, which suppresses both the basal and stimulated secretory activity of normal corticotrophic cells: ACTH measured in the sinus is, therefore, the result of the secretory activity of the tumor tissue. The poor accuracy in lateralization of BIPSS (positive predictive value of 50-70%) makes interpetrosal ACTH gradient alone not sufficient for the localization of the tumor. An accurate exploration of the gland is recommended if a tumor is not found in the predicted area. Despite the fact that BIPSS is an invasive procedure, the occurrence of adverse events is extremely rare, particularly if it is performed by experienced operators in referral centres. © 2016 The authors.

  16. Energy dispersive X-ray fluorescence spectrometry for the direct multi-element analysis of dried blood spots

    NASA Astrophysics Data System (ADS)

    Marguí, E.; Queralt, I.; García-Ruiz, E.; García-González, E.; Rello, L.; Resano, M.

    2018-01-01

    Home-based collection protocols for clinical specimens are actively pursued as a means of improving life quality of patients. In this sense, dried blood spots (DBS) are proposed as a non-invasive and even self-administered alternative to sampling whole venous blood. This contribution explores the potential of energy dispersive X-ray fluorescence spectrometry for the simultaneous and direct determination of some major (S, Cl, K, Na), minor (P, Fe) and trace (Ca, Cu, Zn) elements in blood, after its deposition onto clinical filter papers, thus giving rise to DBS. For quantification purposes the best strategy was to use matrix-matched blood samples of known analyte concentrations. The accuracy and precision of the method were evaluated by analysis of a blood reference material (Seronorm™ trace elements whole blood L3). Quantitative results were obtained for the determination of P, S, Cl, K and Fe, and limits of detection for these elements were adequate, taking into account their typical concentrations in real blood samples. Determination of Na, Ca, Cu and Zn was hampered by the occurrence of high sample support (Na, Ca) and instrumental blanks (Cu, Zn). Therefore, the quantitative determination of these elements at the levels expected in blood samples was not feasible. The methodology developed was applied to the analysis of several blood samples and the results obtained were compared with those reported by standard techniques. Overall, the performance of the method developed is promising and it could be used to determine the aforementioned elements in blood samples in a simple, fast and economic way. Furthermore, its non-destructive nature enables further analyses by means of complementary techniques to be carried out.

  17. Tacrolimus placental transfer at delivery and neonatal exposure through breast milk.

    PubMed

    Zheng, Songmao; Easterling, Thomas R; Hays, Karen; Umans, Jason G; Miodovnik, Menachem; Clark, Shannon; Calamia, Justina C; Thummel, Kenneth E; Shen, Danny D; Davis, Connie L; Hebert, Mary F

    2013-12-01

    The current investigation aims to provide new insights into fetal exposure to tacrolimus in utero by evaluating maternal and umbilical cord blood (venous and arterial), plasma and unbound concentrations at delivery. This study also presents a case report of tacrolimus excretion via breast milk. Maternal and umbilical cord (venous and arterial) samples were obtained at delivery from eight solid organ allograft recipients to measure tacrolimus and metabolite bound and unbound concentrations in blood and plasma. Tacrolimus pharmacokinetics in breast milk were assessed in one subject. Mean (±SD) tacrolimus concentrations at the time of delivery in umbilical cord venous blood (6.6 ± 1.8 ng ml(-1)) were 71 ± 18% (range 45-99%) of maternal concentrations (9.0 ± 3.4 ng ml(-1)). The mean umbilical cord venous plasma (0.09 ± 0.04 ng ml(-1)) and unbound drug concentrations (0.003 ± 0.001 ng ml(-1)) were approximately one fifth of the respective maternal concentrations. Arterial umbilical cord blood concentrations of tacrolimus were 100 ± 12% of umbilical venous concentrations. In addition, infant exposure to tacrolimus through the breast milk was less than 0.3% of the mother's weight-adjusted dose. Differences between maternal and umbilical cord tacrolimus concentrations may be explained in part by placental P-gp function, greater red blood cell partitioning and higher haematocrit levels in venous cord blood. The neonatal drug exposure to tacrolimus via breast milk is very low and likely does not represent a health risk to the breastfeeding infant. © 2013 The Authors. British Journal of Clinical Pharmacology © 2013 The British Pharmacological Society.

  18. Correlation of Blood Gas Parameters with Central Venous Pressure in Patients with Septic Shock; a Pilot Study

    PubMed Central

    Baratloo, Alireza; Rahmati, Farhad; Rouhipour, Alaleh; Motamedi, Maryam; Gheytanchi, Elmira; Amini, Fariba; Safari, Saeed

    2014-01-01

    Objective: To determine the correlation between blood gas parameters and central venous pressure (CVP) in patients suffering from septic shock. Methods: Forty adult patients with diagnosis of septic shock who were admitted to the emergency department (ED) of Shohadaye Tajrish Hospital affiliated with Shahid Beheshti University of Medical Sciences, and met inclusion and exclusion criteria were enrolled. For all patients, sampling was done for venous blood gas analysis, serum sodium and chlorine levels. At the time of sampling; blood pressure, pulse rate and CVP were recorded. Correlation between blood gas parameters and hemodynamic indices were. Results: A significant direct correlation between CVP with anion gap (AG) and inversely with base deficit (BD) and bicarbonate. CVP also showed a relative correlation with pH, whereas it was not correlated with BD/ AG ratio and serum chlorine level. There was no significant association between CVP and clinical parameters including shock index (SI) and mean arterial pressure (MAP). Conclusion: It seems that some of non invasive blood gas parameters could be served as alternative to invasive measures such as CVP in treatment planning of patients referred to an ED with septic shock. PMID:27162870

  19. METHOD FOR THE DETERMINATION OF THE HEMATOCRIT OF AN ORGAN IN VIVO (in Italian)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cultrera, G.

    1963-01-01

    A method, based on the almost simuitaneous labeling of the plasma with Cl/sub 3/Cr/sup 51/ and of the red blood cells with Na/sub 2/Cr/sup 51/O/sub 4/, is described, by which the hematocrit can be measured in vivo. The patient's plasma is labeled, and the radioactivity is then almost simultaneously measured in vivo over the organ considered, e.g., the heart; the plasma radioactivity is measured in a sample of blood taken from a vein. The same procedure is then repeated considering the radioactivity of the red blood cells. By applying a formula, the hematocrit of the examined organ can then bemore » calculated. The results of measurements of the cardiac hematocrit were fairly satisfactory as compared with measurements of the venous hematocrit and showed that two factors are of fundamental importance in order to obtain accurate measurements. Highly sensitive counters must be used and relatively large doses of isotope must be employed. Unless these conditions are observed, results will be unsatisfactory on account of the high statistical error. (auth)« less

  20. Comparative effectiveness of venous thromboembolism prophylaxis options for the patient undergoing total hip and knee replacement: a network meta-analysis.

    PubMed

    Kapoor, A; Ellis, A; Shaffer, N; Gurwitz, J; Chandramohan, A; Saulino, J; Ishak, A; Okubanjo, T; Michota, F; Hylek, E; Trikalinos, T A

    2017-02-01

    Essentials Despite trial data, guidelines have not endorsed direct oral Xa inhibitors above other options. We provide profiles of venous thromboembolism and hemorrhage risk for 12 options. Direct oral Xa inhibitors had a favorable profile compared with low-molecular-weight heparin. Other options did not have favorable profiles compared with low-molecular-weight heparin. Background There are numerous trials and several meta-analyses comparing venous thromboembolism (VTE) prophylaxis options after total hip and knee replacement (THR and TKR). None have included simultaneous comparison of new with older options. Objective To measure simultaneously the relative risk of VTE and hemorrhage for 12 prophylaxis options. Methods We abstracted VTE and hemorrhage information from randomized controlled trials published between January 1990 and June 2016 comparing 12 prophylaxis options. We then constructed networks to compute the relative risk for each option, relative to once-daily dosing with low-molecular-weight heparin (LMWH) Low. Results Main: Relative to LMWH Low, direct oral Xa inhibitors had the lowest risk of total deep vein thrombosis (DVT)-asymptomatic and symptomatic- (odds ratio [OR], 0.45; 95% confidence interval [CI], 0.35-0.57), translating to 53-139 fewer DVTs per 1000 patients. Vitamin K antagonists (VKAs) titrated to International Normalized Ratio [INR] 2-3 predicted 56% more DVT events (OR, 1.56; 95% CI, 1.14-2.14). Aspirin performed similarly (OR, 0.80; 95% CI, 0.34-1.86), although small numbers prohibit firm conclusions. Direct oral Xa inhibitors did not lead to significantly more bleeding (OR, 1.21; 95% CI, 0.79-1.90). Secondary: Relative to LMWH Low, direct oral Xa inhibitors prevented 4-fold more symptomatic DVTs (OR, 0.25; 95% CI, 0.13-0.47). Conclusions Relative to LMWH Low, direct oral Xa inhibitors had a more favorable profile of VTE and hemorrhage risk, whereas VKAs had a less favorable profile. The profile of other agents was not more or less favorable. Clinicians should consider these profiles when selecting prophylaxis options. © 2016 International Society on Thrombosis and Haemostasis.

  1. Immune Blood Sample Draw

    NASA Image and Video Library

    2012-04-26

    ISS030-E-257690 (26 April 2012) --- European Space Agency astronaut Andre Kuipers, Expedition 30 flight engineer, prepares for IMMUNE venous blood sample draws in the Columbus laboratory of the International Space Station. Following the blood draws, the samples were temporarily stowed in the Minus Eighty Laboratory Freezer for ISS 1 (MELFI-1) and later packed together with saliva samples on the Soyuz TMA-22 for return to Earth for analysis.

  2. Arterial stick

    MedlinePlus

    ... venous blood) mainly in its content of dissolved gases . Testing arterial blood shows the makeup of the ... arteries. Blood samples are mainly taken to measure gases in the arteries. Abnormal results may point to ...

  3. Wet-cupping removes oxidants and decreases oxidative stress.

    PubMed

    Tagil, Suleyman Murat; Celik, Huseyin Tugrul; Ciftci, Sefa; Kazanci, Fatmanur Hacievliyagil; Arslan, Muzeyyen; Erdamar, Nazan; Kesik, Yunus; Erdamar, Husamettin; Dane, Senol

    2014-12-01

    Wet-cupping therapy is one of the oldest known medical techniques. Although it is widely used in various conditions such as acute\\chronic inflammation, infectious diseases, and immune system disorders, its mechanism of action is not fully known. In this study, we investigated the oxidative status as the first step to elucidate possible mechanisms of action of wet cupping. Wet cupping therapy is implemented to 31 healthy volunteers. Venous blood samples and Wet cupping blood samples were taken concurrently. Serum nitricoxide, malondialdehyde levels and activity of superoxide dismutase and myeloperoxidase were measured spectrophotometrically. Wet cupping blood had higher activity of myeloperoxidase, lower activity of superoxide dismutase, higher levels of malondialdehyde and nitricoxide compared to the venous blood. Wet cupping removes oxidants and decreases oxidative stress. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. Phlebitis risk varies by peripheral venous catheter site and increases after 96 hours: a large multi-centre prospective study.

    PubMed

    Cicolini, Giancarlo; Manzoli, Lamberto; Simonetti, Valentina; Flacco, Maria Elena; Comparcini, Dania; Capasso, Lorenzo; Di Baldassarre, Angela; Eltaji Elfarouki, Ghaleb

    2014-11-01

    This multi-centre prospective field study evaluated whether peripheral venous catheter site of insertion influences the risk of catheter-related phlebitis. Potential predictors of phlebitis were also investigated. Millions of patients worldwide use peripheral venous catheters, which frequently cause local complications including phlebitis, infection and obstruction. Although phlebitis predictors have been broadly investigated, uncertainties remain on the potential effect of cannulation anatomical site, duration and the appropriate time for catheter removal. A prospective cohort design was carried out from January-June 2012. The clinical course of each patient who received a new peripheral venous catheter for any cause in five Italian hospitals was followed by trained nurses until catheter removal. The presence of phlebitis was assessed every 24 hours using the Visual Infusion Phlebitis score. Analyses were based upon multilevel mixed-effects regression. The final sample consisted of 1498 patients. The average time for catheters in situ was 65·6 hours and 23·6% of the catheters were in place beyond 96 hours. Overall phlebitis incidence was 15·4%, 94·4% of which were grade 1. The likelihood of phlebitis independently increased with increasing catheter duration, being highest after 96 hours. Compared with patients with catheter placed in the dorsum of the hand (22·8% of the sample), those with the catheter located in the antecubital fossa (34·1%) or forearm were less likely to have a phlebitis of any grade. Antecubital fossa and forearm veins may be preferential sites for peripheral venous cannulation. Our results support Centers for Disease Control and Prevention recommendations to replace catheters in adults no later than 96 hours. A relevant proportion of healthcare personnel did not adhere to such guidelines - more attention to this issue is required. © 2014 John Wiley & Sons Ltd.

  5. Establishment of a hepatic cirrhosis and portal hypertension model by hepatic arterial perfusion with 80% alcohol.

    PubMed

    Wang, Lei; He, Fu-Liang; Liu, Fu-Quan; Yue, Zhen-Dong; Zhao, Hong-Wei

    2015-08-28

    To determine the feasibility and safety of establishing a porcine hepatic cirrhosis and portal hypertension model by hepatic arterial perfusion with 80% alcohol. Twenty-one healthy Guizhou miniature pigs were randomly divided into three experimental groups and three control groups. The pigs in the three experimental groups were subjected to hepatic arterial perfusion with 7, 12 and 17 mL of 80% alcohol, respectively, while those in the three control groups underwent hepatic arterial perfusion with 7, 12 and 17 mL of saline, respectively. Hepatic arteriography and direct portal phlebography were performed on all animals before and after perfusion, and the portal venous pressure and diameter were measured before perfusion, immediately after perfusion, and at 2, 4 and 6 wk after perfusion. The following procedures were performed at different time points: routine blood sampling, blood biochemistry, blood coagulation and blood ammonia tests before surgery, and at 2, 4 and 6 wk after surgery; hepatic biopsy before surgery, within 6 h after surgery, and at 1, 2, 3, 4 and 5 wk after surgery; abdominal enhanced computed tomography examination before surgery and at 6 wk after surgery; autopsy and multi-point sampling of various liver lobes for histological examination at 6 wk after surgery. In experimental group 1, different degrees of hepatic fibrosis were observed, and one pig developed hepatic cirrhosis. In experimental group 2, there were cases of hepatic cirrhosis, different degrees of increased portal venous pressure, and intrahepatic portal venous bypass, but neither extrahepatic portal-systemic bypass circulation nor death occurred. In experimental group 3, two animals died and three animals developed hepatic cirrhosis, and different degrees of increased portal venous pressure and intrahepatic portal venous bypass were also observed, but there was no extrahepatic portal-systemic bypass circulation. It is feasible to establish an animal model of hepatic cirrhosis and portal hypertension by hepatic arterial perfusion with 80% alcohol, however, the safety of this model depends on a suitable perfusion dose.

  6. Diabetes and hypertension increase the placental and transcellular permeation of the lipophilic drug diazepam in pregnant women

    PubMed Central

    2013-01-01

    Background Previous studies carried out in our laboratories have demonstrated impaired drug permeation in diabetic animals. In this study the permeation of diazepam (after a single dose of 5 mg/day, administered intramuscularly) will be investigated in diabetic and hypertensive pregnant women. Methods A total 75 pregnant women were divided into three groups: group 1 (healthy control, n = 31), group 2 (diabetic, n = 14) and group 3 (hypertensive, n = 30). Two sets of diazepam plasma concentrations were collected and measured (after the administration of the same dose of diazepam), before, during and after delivery. The first set of blood samples was taken from the mother (maternal venous plasma). The second set of samples was taken from the fetus (fetal umbilical venous and arterial plasma). In order to assess the effect of diabetes and hypertension on diazepam placental-permeation, the ratios of fetal to maternal blood concentrations were determined. Differences were considered statistically significant if p ≤ 0.05. Results The diabetes and hypertension groups have 2-fold increase in the fetal umbilical-venous concentrations, compared to the maternal venous concentrations. Feto: maternal plasma-concentrations ratios were higher in diabetes (2.01 ± 1.10) and hypertension (2.26 ± 1.23) groups compared with control (1.30 ± 0.48) while, there was no difference in ratios between the diabetes and hypertension groups. Umbilical-cord arterial: venous ratios (within each group) were similar among all groups (control: 0.97 ± 0.32; hypertension: 1.08 ± 0.60 and diabetes: 1.02 ± 0.77). Conclusions On line with our previous findings which demonstrate disturbed transcellular trafficking of lipophilic drugs in diabetes, this study shows significant increase in diazepam placental-permeation in diabetic and hypertensive pregnant women suggesting poor transcellular control of drug permeation and flux, and bigger exposure of the fetus to drug-placental transport. PMID:24134697

  7. Intraadrenal corticotropin in bilateral macronodular adrenal hyperplasia.

    PubMed

    Louiset, Estelle; Duparc, Céline; Young, Jacques; Renouf, Sylvie; Tetsi Nomigni, Milène; Boutelet, Isabelle; Libé, Rossella; Bram, Zakariae; Groussin, Lionel; Caron, Philippe; Tabarin, Antoine; Grunenberger, Fabienne; Christin-Maitre, Sophie; Bertagna, Xavier; Kuhn, Jean-Marc; Anouar, Youssef; Bertherat, Jérôme; Lefebvre, Hervé

    2013-11-28

    Bilateral macronodular adrenal hyperplasia is a rare cause of primary adrenal Cushing's syndrome. In this form of hyperplasia, hypersecretion of cortisol suppresses the release of corticotropin by pituitary corticotrophs, which results in low plasma corticotropin levels. Thus, the disease has been termed corticotropin-independent macronodular adrenal hyperplasia. We examined the abnormal production of corticotropin in these hyperplastic adrenal glands. We obtained specimens of hyperplastic macronodular adrenal tissue from 30 patients with primary adrenal disease. The corticotropin precursor proopiomelanocortin and corticotropin expression were assessed by means of a polymerase-chain-reaction assay and immunohistochemical analysis. The production of corticotropin and cortisol was assessed in 11 specimens with the use of incubated explants and cell cultures coupled with hormone assays. Corticotropin levels were measured in adrenal and peripheral venous blood samples from 2 patients. The expression of proopiomelanocortin messenger RNA (mRNA) was detected in all samples of hyperplastic adrenal tissue. Corticotropin was detected in steroidogenic cells arranged in clusters that were disseminated throughout the adrenal specimens. Adrenal corticotropin levels were higher in adrenal venous blood samples than in peripheral venous samples, a finding that was consistent with local production of the peptide within the hyperplastic adrenals. The release of adrenal corticotropin was stimulated by ligands of aberrant membrane receptors but not by corticotropin-releasing hormone or dexamethasone. A semiquantitative score for corticotropin immunostaining in the samples correlated with basal plasma cortisol levels. Corticotropin-receptor antagonists significantly inhibited in vitro cortisol secretion. Cortisol secretion by the adrenals in patients with macronodular hyperplasia and Cushing's syndrome appears to be regulated by corticotropin, which is produced by a subpopulation of steroidogenic cells in the hyperplastic adrenals. Thus, the hypercortisolism associated with bilateral macronodular adrenal hyperplasia appears to be corticotropin-dependent. (Funded by the Agence Nationale de la Recherche and others.).

  8. Venous thromboembolic prophylaxis after simultaneous bilateral total knee arthroplasty: aspirin versus warfarin.

    PubMed

    Goel, R; Fleischman, A N; Tan, T; Sterbis, E; Huang, R; Higuera, C; Parvizi, J; Rothman, R H

    2018-01-01

    The aims of this study were to compare the efficacy of two agents, aspirin and warfarin, for the prevention of venous thromboembolism (VTE) after simultaneous bilateral total knee arthroplasty (SBTKA), and to elucidate the risk of VTE conferred by this procedure compared with unilateral TKA (UTKA). A retrospective, multi-institutional study was conducted on 18 951 patients, 3685 who underwent SBTKA and 15 266 who underwent UTKA, using aspirin or warfarin as VTE prophylaxis. Each patient was assigned an individualised baseline VTE risk score based on a system using the Nationwide Inpatient Sample. Symptomatic VTE, including pulmonary embolism (PE) and deep vein thrombosis (DVT), were identified in the first 90 days post-operatively. Statistical analyses were performed with logistic regression accounting for baseline VTE risk. The adjusted incidence of PE following SBTKA was 1.0% (95% confidence interval (CI) 0.86 to 1.2) with aspirin and 2.2% (95% CI 2.0 to 2.4) with warfarin. Similarly, the adjusted incidence of VTE following SBTKA was 1.6% (95% CI 1.1 to 2.3) with aspirin and 2.5% (95% CI 1.9 to 3.3) with warfarin. The risk of PE and VTE were reduced by 66% (odds ratio (OR) 0.44, 95% CI 0.25 to 0.78) and 38% (OR 0.62, 95% CI 0.38 to 1.0), respectively, using aspirin. In addition, the risk of PE was 204% higher for patients undergoing SBTKA relative to those undergoing UTKA. For each ten-point increase in baseline VTE risk, the risk of PE increased by 25.5% for patients undergoing SBTKA compared with 10.5% for those undergoing UTKA. Patients with a history of myocardial infarction or peripheral vascular disease had the greatest increase in risk from undergoing SBTKA instead of UTKA. Aspirin is more effective than warfarin for the prevention of VTE following SBTKA, and serves as the more appropriate agent for VTE prophylaxis for patients in all risk categories. Furthermore, patients undergoing SBTKA are at a substantially increased risk of VTE, even more so for those with significant underlying risk factors. Patients should be informed about the risks associated with undergoing SBTKA. Cite this article: Bone Joint J 2018;100-B(1 Supple A):68-75. ©2018 The British Editorial Society of Bone and Joint Surgery.

  9. Are there clinical signs and symptoms of infection to indicate the presence of multidrug-resistant bacteria in venous ulcers?

    PubMed

    Dos Santos, Silvana de Lima Vieira; Martins, Marlene Andrade; do Prado, Marinésia Aparecida; Soriano, José Verdú; Bachion, Maria Márcia

    2017-12-01

    The selection of topical and systemic therapies for the treatment of venous ulcers with signs of infection is challenging and should be accompanied by specific precautionary measures to protect against cross-contamination in the presence of multidrug-resistant microorganisms. However, there are still no clinical indicators for this situation, and confirmation of resistant strains occurs through culture and sensitivity, which can take up to 14 days. During this period, protective measures may no longer be taken, contributing to the spread of these pathogens. This study aimed to analyze the relationship between clinical signs and symptoms of infection in venous ulcers and the presence of antimicrobial-resistant Staphylococcus aureus and/or Pseudomonas spp. A cross-sectional study was developed including 69 patients with 98 venous ulcers. Clinical observation protocol was applied to detect infection indicators established by the European Wound Management Association and microbiological analysis of samples of the lesions. Fisher's exact test and χ 2 were used for analyses (P < 0.05). Two indicators of infection predominated (f >70%): discoloration of the opaque type and/or dark brick red and increased exudate volume; 31 (31.6%) ulcer samples showed positive culture for the bacteria studied. There was no relationship between signs and symptoms of infection and the presence of multidrug-resistant microorganisms. Taking into account the percentage of lesions with resistant strains, for safe care, contact precautionary measures should be implemented in the treatment rooms, in addition to standard precautions. Copyright © 2017 Society for Vascular Nursing, Inc. Published by Elsevier Inc. All rights reserved.

  10. [On Individualization of Therapeutic Doses of Optical Radiation according to Changes in Parameters of Blood Oxygenation].

    PubMed

    Zalesskaya, G A

    2015-01-01

    The effect of in vivo laser irradiation by optical radiation on blood from different patients is studied. The objects of research were three series of blood samples from patients whose treatment course included extracorporeal UV blood irradiation, intravenous laser blood irradiation and supra-venous blood laser irradiation. Before and after irradiation the results on optic oximetry and gas content of venous blood were compared. The results of positive and negative influence of blood irradiation on characteristics of an oxygen exchange in separate patients and on the maintenance of some products of metabolism are represented. It is shown that at the same power dose, their changes depend on individual, initial values of hemoglobin oxygen saturation of venous blood and its photoinduced changes which objectively reflect individual sensitivity of patients to the action of optical radiation on blood and can be used for assessment of the efficiency of phototherapy.

  11. [Capillary HbA1c determination on type 2 diabetes patients in a primary health centre].

    PubMed

    Font, María Teresa Carrera; Brichs, María Claustre Solé; Álvarez, María Clara Sala; Olivella, Jose María Navarro; Turó, Josefina Servent; Fernández, María Pilar Felipe

    2011-10-01

    To determine the reliability and practicability of the point-of-care- test (POCT) analyzer, Afinion, for capillary HbA1c testing. To assess the benefits of its implementation on the intra-annual follow up of type 2 diabetic patients. Descriptive cross-sectional study. Analytical validation of the Afinion reader. Primary Health Care (CAP Carmel and Bon Pastor Clinic Laboratory). A total of 94 type 2 diabetic patients selected according to their previous HbA1c value. We performed one capillary puncture and one venous extraction on each visit. The capillary sample was assessed in real time on the Afinion in the Primary Health Care Centre and the venous sample was sent to Bon Pastor Clinic Laboratory for assessment on an Afinion analyzer and by a high performance liquid chromatrography (HPLC) reference method. Practicability was assesses by both by the operators of the Afinion and the patients using an 11 question questionnaire. The efficiency in terms of process timings was also evaluated. Intra-serial coefficient of variation (CV) was lower than 1% and inter-serial lower than 3%. The regression analysis showed: Afinion capillary sample=0.95 Afinion venous+0.21. No systematic or proportional error was detected in the 95% confidence interval (95% CI). The comparison between venous HPLC and Afinion showed: Afinion capillary sample=0.80 HPLC+1.14. A statistically significant difference was shown for these values at the 95% CI. Practicability was valued by users from 7 to 9.2 (professionals) and from 7.7 to 9.2 (patients). Implementation of the Afinion capillary method for intra-annual testing in follow up of diabetic patients could result in the saving of 600-900 professional hours/year. Afinion seems to be a good choice for the intra-annual determination of HbA1c when compared to the traditional process due to its accessibility, practicability and efficiency. Professionals should know the limitations of the POCT method in order to consider the validity of the results. Copyright © 2010 Elsevier España, S.L. All rights reserved.

  12. Bacterial signatures in thrombus aspirates of patients with lower limb arterial and venous thrombosis.

    PubMed

    Vakhitov, Damir; Tuomisto, Sari; Martiskainen, Mika; Korhonen, Janne; Pessi, Tanja; Salenius, Juha-Pekka; Suominen, Velipekka; Lehtimäki, Terho; Karhunen, Pekka J; Oksala, Niku

    2018-06-01

    Increasing data supports the role of bacterial inflammation in adverse events of cardiovascular and cerebrovascular diseases. In our previous research, DNA of bacterial species found in coronary artery thrombus aspirates and ruptured cerebral aneurysms were mostly of endodontic and periodontal origin, where Streptococcus mitis group DNA was the most common. We hypothesized that the genomes of S mitis group could be identified in thrombus aspirates of patients with lower limb arterial and deep venous thrombosis. Thrombus aspirates and control blood samples taken from 42 patients with acute or acute-on-chronic lower limb ischemia (Rutherford I-IIb) owing to arterial or graft thrombosis (n = 31) or lower limb deep venous thrombosis (n = 11) were examined using a quantitative real-time polymerase chain reaction to detect all possible bacterial DNA and DNA of S mitis group in particular. The samples were considered positive, if the amount of bacterial DNA in the thrombus aspirates was 2-fold or greater in comparison with control blood samples. In the positive samples the mean difference for the total bacterial DNA was 12.1-fold (median, 7.1), whereas the differences for S mitis group DNA were a mean of 29.1 and a median of 5.2-fold. Of the arterial thrombus aspirates, 57.9% were positive for bacterial DNA, whereas bacterial genomes were found in 75% of bypass graft thrombosis with 77.8% of the prosthetic grafts being positive. Of the deep vein thrombus aspirates, 45.5% contained bacterial genomes. Most (80%) of bacterial DNA-positive cases contained DNA from the S mitis group. Previous arterial interventions were significantly associated with the occurrence of S mitis group DNA (P = .049, Fisher's exact test). This is the first study to report the presence of bacterial DNA, predominantly of S mitis group origin, in the thrombus aspirates of surgical patients with lower limb arterial and deep venous thrombosis, suggesting their possible role in the pathogenesis of thrombotic events. Additional studies will, however, be needed to reach a final conclusion. Copyright © 2017 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  13. Correlation Between Maternal and Fetal Insulin Resistance in Pregnant Women with Gestational Diabetes Mellitus.

    PubMed

    Wang, Xuqin; Yang, Ting; Miao, Jingkun; Liu, Huan; Wu, Kaifeng; Guo, Jing; Chen, Jie; Li, Tingyu

    2018-06-01

    Offspring of mothers with gestational diabetes mellitus (GDM) are far more likely to develop type 2 diabetes. The aim of this study was to investigate the effect of the insulin metabolism of pregnant women with GDM in late pregnancy on the insulin metabolism of the fetuses and their correlation. This study enrolled 55 pregnant women with GDM and 87 control subjects. Fasting venous blood samples and umbilical venous blood samples (reflecting fetal metabolism) were collected from the study subjects. All blood samples were used to evaluate the blood glucose and insulin concentrations. The blood glucose and insulin concentrations were measured using an automatic biochemical analyser and radioimmunoassay, respectively. The homeostasis model assessment (HOMA) was performed to assess the insulin resistance of mother and fetus. 1. The fasting blood glucose, fasting insulin, and HOMA-IR of pregnant women in the late pregnancy GDM group were all significantly higher than those in the control group (fasting blood glucose: 4.70 ± 0.11 vs. 4.11 ± 0.05 mmol/L, p < 0.001; fasting insulin: 44.1 ± 6.76 vs. 25.1 ± 3.58 µU/mL, p = 0.013; HOMA-IR: 8.92 ± 1.25 vs. 5.39 ± 0.83, p = 0.012); 2. The results of logistic regression analyses showed that maternal age, pre-pregnancy body mass index (BMI), and family history of diabetes were high-risk factors for the development of GDM in pregnant women. 3. The insulin level and HOMA-IR in the umbilical venous blood of the late pregnancy GDM group were both significantly higher than those in the control group (insulin: 10.1 ± 1.41 vs. 6.38 ± 0.49 µU/mL, p = 0.035; HOMA-IR: 1.60 ± 0.22 vs. 1.07 ± 0.08, p = 0.006). 4. The umbilical venous blood HOMA-IR in the GDM group positively correlated with the maternal HOMA-IR and fasting insulin level. The neonatal ponderal index (PI) in the GDM group positively correlated with the umbilical venous blood HOMA-IR and insulin level. The HOMA-IR was significantly higher in the late pregnancy GDM women and their fetuses than in the control group. In addition, fetal HOMA-IR positively correlated to maternal HOMA-IR in late pregnancy GDM women.

  14. Combined technetium radioisotope penile plethysmography and xenon washout: A technique for evaluating corpora cavernosal inflow and outflow during early tumescence

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schwartz, A.N.; Graham, M.M.

    1991-03-01

    Combined technetium radioisotope penile plethysmography and xenon washout is a new technique that measures both corporal arterial inflow and venous sinusoidal outflow during early tumescence in patients with erectile dysfunction. Fourteen patients were studied using 99mTc-RBCs to measure inflow and 133Xe or 127Xe in saline to measure outflow. Tumescence was induced by injecting papaverine intracorporally. Peak corporal rates corrected for inflow (r = 0.88) and uncorrected for outflow (r = 0.91) and change in volume over 2 min centered around peak inflow (r = 0.96) all correlated with angiography. Outflow measurements did not correlate with intracorporal resistance. Thus, outflow ratesmore » alone could not be used to predict venous sinusoidal competence. Normal inflow rate is greater than 20 ml/min; probable normal 12-20; indeterminate inflow 7-12; and abnormal inflow less than 7 ml/min. Technetium-99m radioisotope penile plethysmography and xenon washout can be performed together and both provide a method for simultaneously evaluating the relationship between corporal inflow and outflow rates in patients with erectile dysfunction.« less

  15. In-Hospital Mortality with Deep Venous Thrombosis.

    PubMed

    Stein, Paul D; Matta, Fadi; Hughes, Mary J

    2017-05-01

    Little is known about the in-hospital mortality of deep venous thrombosis in recent years. This investigation was undertaken to determine trends in in-hospital mortality in patients with deep venous thrombosis and mortality according to age. Administrative data were analyzed from the National (Nationwide) Inpatient Sample, 2003-2012. We determined in-hospital all-cause mortality according to year and age among patients with a primary (first-listed) diagnosis of deep venous thrombosis. We analyzed all such patients and we analyzed those who had none of the comorbid conditions listed in the Charlson Comorbidity Index. From 2003-2012, 1,603,690 hospitalized patients had a primary diagnosis of deep venous thrombosis. All-cause in-hospital mortality decreased from 1.3% in 2003 to 0.6% in 2012. Mortality increased with age from 0.1% in those aged 18-20 years to 1.5% in those over age 80 years. All-cause in-hospital mortality in those with no comorbid conditions according to the Charlson Comorbidity Index (1,094,184 patients) decreased from 1.1% in 2003 to 0.5% in 2012. Presumably, these deaths were from pulmonary embolism. All-cause mortality in those with no comorbid conditions increased with age from 0.1% in those aged 18-20 years to 1.4% in those over aged 80 years. All-cause death and death due to pulmonary embolism in patients hospitalized with a primary diagnosis of deep venous thrombosis decreased from 2003-2012. The death rate increased with age. The decreased mortality over the period of investigation may have resulted from a shift toward use of low-molecular-weight heparins and newer anticoagulants. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Cryptococcus laurentii fungaemia in a cervical cancer patient.

    PubMed

    Neves, Rejane Pereira; Lima Neto, Reginaldo Gonçalves de; Leite, Melyna Chaves; Silva, Vanessa Karina Alves da; Santos, Franz de Assis Graciano dos; Macêdo, Danielle Patrícia Cerqueira

    2015-01-01

    Infections caused by emerging Cryptococcus non-neoformans species are being reported with increasingly frequency. Here, we present a case of fungaemia by Cryptococcus laurentii in a woman receiving aggressive immunosuppressive therapy for cervical neoplasia. Three venous blood samples were aseptically collected on consecutive days and C. laurentii was isolated and identified through phenotypic and molecular methods. After central venous catheter removal and appropriate antifungal therapy, the patient showed significant improvement and blood culture became negative. Thus, patients following immunosuppressive therapies and using invasive medical devices are at risk of C. laurentii blood infections. Copyright © 2015 Elsevier Editora Ltda. All rights reserved.

  17. Lead poisoning in children.

    PubMed

    Warniment, Crista; Tsang, Katrina; Galazka, Sim S

    2010-03-15

    The prevalence and severity of childhood lead poisoning have been greatly reduced since the removal of lead from paint and gasoline in the 1970s. Despite these efforts, approximately 310,000 U.S. children younger than five years have elevated blood lead levels. Health care professionals should perform targeted screening for lead poisoning in children who are Medicaid-enrolled or -eligible, foreign born, or identified as high risk by the Centers for Disease Control and Prevention (CDC) location-specific recommendations or by a personal risk questionnaire. Venous sampling is the preferred method for measuring blood lead levels, but a carefully collected finger-stick sample is an acceptable alternative. Capillary samples of elevated levels should be confirmed by a venous sample. The CDC recommends that the threshold for follow-up and intervention of lead poisoning be a blood lead level of 10 microg per dL or higher. Recommendations for treatment of elevated blood levels include a thorough environmental investigation, laboratory testing when appropriate, iron supplementation for iron-deficient children, and chelation therapy for blood lead levels of 45 microg per dL or more. Prevention consists of education and avoidance of lead-contaminated products.

  18. Induction of sister chromatid exchange in the presence of gadolinium-DTPA and its reduction by dimethyl sulfoxide

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yamazaki, Etsuo; Fukuda, Hozumi; Shibuya, Hitoshi

    The authors investigate the frequency of sister chromatid exchange (SCE) after the addition of gadolinium (Gd)-DTPA to venous blood samples. Venous blood was obtained from nonsmokers. Samples were incubated with Gd-DTPA alone or in combination with mitomycin C, cytarabine, and dimethyl sulfoxide (DMSO), and then evaluated for SCEs. The frequency of SCE increased with the concentration of Gd-DTPA and as each chemotherapeutic agent was added. Sister chromatid exchange frequencies were lower when the blood was treated with a combination of Gd-DTPA and DMSO compared with Gd-DTPA alone. The increase in frequency of SCE seen after the addition of Gd-DTPA wasmore » decreased by the addition of DMSO, indicating the production of hydroxyl radicals. The effect likely is dissociation-related. 14 refs., 6 tabs.« less

  19. An unusual case of concurrent insulinoma and nesidioblastosis.

    PubMed

    Bright, Elizabeth; Garcea, Giuseppe; Ong, Seok L; Madira, Webster; Berry, David P; Dennison, Ashley R

    2008-09-02

    Endogenous hyperinsulinaemic hypoglycaemia in adults is most commonly caused by an insulinoma. Adult nesidioblastosis is rarely reported. To the best of our knowledge the presence of both insulinoma and nesidioblastosis has not been reported before. We report a case of a 35-year-old female presenting with neuroglycaemic symptoms. A supervised 72-hour fast confirmed hypoglycaemia in the presence of hyperinsulinaemia. Thorough pre-operative biochemical and radiological investigations, including selective splenic, superior mesenteric and portal venous sampling inferred a tentative diagnosis of adult nesidioblastosis. However, a grossly elevated insulin level within the splenic vein on a second set of venous sampling produced a high index of suspicion for the presence of an insulinoma. At surgical exploration both an insulinoma and nesidioblastosis were identified and confirmed by histological examination. We report an even rarer entity of concurrent insulinoma and nesidioblastosis.

  20. Eleven-Year Retrospective Report of Super-Selective Venous Sampling for the Evaluation of Recurrent or Persistent Hyperparathyroidism in 32 Patients.

    PubMed

    Habibollahi, Peiman; Shin, Benjamin; Shamchi, Sara P; Wachtel, Heather; Fraker, Douglas L; Trerotola, Scott O

    2018-01-01

    Parathyroid venous sampling (PAVS) is usually reserved for patients with persistent or recurrent hyperparathyroidism after parathyroidectomy with inconclusive noninvasive imaging studies. A retrospective study was performed to evaluate the diagnostic efficacy of super-selective PAVS (SSVS) in patients needing revision neck surgery with inconclusive imaging. Patients undergoing PAVS between 2005 and 2016 due to persistent or recurrent hyperparathyroidism following surgery were reviewed. PAVS was performed in all patients using super-selective technique. Single-value measurements within central neck veins performed as part of super-selective PAVS were used to simulate selective venous sampling (SVS) and allow for comparison to data, which might be obtained in a non-super-selective approach. 32 patients (mean age 51 ± 15 years; 8 men and 24 women) met inclusion and exclusion criteria. The sensitivity and positive predictive value (PPV) of SSVS for localizing the source of elevated PTH to a limited area in the neck or chest was 96 and 84%, respectively. Simulated SVS, on the other hand, had a sensitivity of 28% and a PPV of 89% based on the predefined gold standard. SSVS had a significantly higher sensitivity compared to simulated SVS (p < 0.001). SSVS is highly effective in localizing the source of hyperparathyroidism in patients undergoing revision surgery for hyperparathyroidism in whom noninvasive imaging studies are inconclusive. SSVS data had also markedly higher sensitivity for localizing disease in these patients compared to simulated SVS.

  1. Efficacy of adrenal venous sampling is increased by point of care cortisol analysis

    PubMed Central

    Viste, Kristin; Grytaas, Marianne A; Jørstad, Melissa D; Jøssang, Dag E; Høyden, Eivind N; Fotland, Solveig S; Jensen, Dag K; Løvås, Kristian; Thordarson, Hrafnkell; Almås, Bjørg; Mellgren, Gunnar

    2013-01-01

    Primary aldosteronism (PA) is a common cause of secondary hypertension and is caused by unilateral or bilateral adrenal disease. Treatment options depend on whether the disease is lateralized or not, which is preferably evaluated with selective adrenal venous sampling (AVS). This procedure is technically challenging, and obtaining representative samples from the adrenal veins can prove difficult. Unsuccessful AVS procedures often require reexamination. Analysis of cortisol during the procedure may enhance the success rate. We invited 21 consecutive patients to participate in a study with intra-procedural point of care cortisol analysis. When this assay showed nonrepresentative sampling, new samples were drawn after redirection of the catheter. The study patients were compared using the 21 previous procedures. The intra-procedural cortisol assay increased the success rate from 10/21 patients in the historical cohort to 17/21 patients in the study group. In four of the 17 successful procedures, repeated samples needed to be drawn. Successful sampling at first attempt improved from the first seven to the last seven study patients. Point of care cortisol analysis during AVS improves success rate and reduces the need for reexaminations, in accordance with previous studies. Successful AVS is crucial when deciding which patients with PA will benefit from surgical treatment. PMID:24169597

  2. Manual calf massage and passive ankle motion reduce the incidence of deep vein thromboembolism after total hip arthroplasty.

    PubMed

    Imai, Norio; Ito, Tomoyuki; Suda, Ken; Miyasaka, Dai; Endo, Naoto

    2017-07-01

    Venous thromboembolism is one of the general complications following total hip arthroplasty, wherein various preventive treatments have been recommended. Several studies reported that venous thromboembolism incidence after total hip arthroplasty was similar in patients who were administered prophylaxis with a conventional mechanical procedure alone, and those who were administered pharmacological anticoagulation therapy. Therefore, the optimum methods of prophylaxis are still controversial. The purpose of this study was to investigate whether manual calf massage and passive ankle motion could lower the risk for venous thromboembolism after total hip arthroplasty. We retrospectively reviewed the data of 126 consecutive patients undergoing elective primary unilateral total hip arthroplasty wherein manual calf massage and passive ankle motion were performed after the surgery at our hospitals between January and October 2014. The 138 patients of the control group underwent total hip arthroplasty using the same surgical approach and pre- and postoperative protocols without this mechanical prophylaxis between January and December 2013. This mechanical prophylaxis was performed simultaneously 30 times during approximately 10 s; these procedures were repeated thrice immediately after total hip arthroplasty. Duplex ultrasonography was performed to observe the veins of both legs in all the patients on postoperative day 7. The incidence of deep vein thrombosis was 6.52% and 0.79% in the control and manual calf massage and passive ankle motion groups, respectively. The odds ratio for the manual calf massage and passive ankle motion groups was 8.72. Performing this mechanical prophylaxis reduced the incidence of venous thromboembolism after total hip arthroplasty. This mechanical prophylaxis is not only simple and easy, but is also safe and inexpensive. We therefore recommend that manual calf massage and passive ankle motion be performed in patients who will undergo total hip arthroplasty, if deep vein thrombosis does not exist before the surgery. Copyright © 2017 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.

  3. Brightness of venous blood in South American camelids: implications for jugular catheterization.

    PubMed

    Grint, Nicola; Dugdale, Alexandra

    2009-01-01

    To compare the brightness of South American camelid venous blood to that of Equidae. Prospective clinical evaluation. Twelve South American camelids (eight llamas, four alpacas), eight horses and ponies (control group). Appropriately sized catheters were placed in the jugular vein of each animal under local anaesthesia. The blood spilt before the catheter was capped was caught on a white tile. A sample of blood was drawn for blood-gas analysis. The brightness of the blood (both on the tile and in the syringe) was matched to a colour chart (1 = darkest red, 8 = brightest red) by a single observer under bright light conditions. Packed cell volume (PCV) and partial pressure of oxygen (PvO(2)) in the blood were also measured on the syringe blood. Normally distributed data were compared using a two tailed t-test, and non-normally distributed data were compared using a Mann-Whitney U-test. Significance was set at p < 0.05. Camelid venous blood was significantly brighter red than that of horses and ponies both on the white tile (p = 0.0003) and in the syringe (p = 0.0001). PCV was significantly lower in camelids (32 +/- 4%) compared with horses (37 +/- 5%). Partial pressure of oxygen values were similar between groups. Jugular venous blood in alpacas and llamas is significantly brighter red than that of horses. Colour should not be used as a sole determinant of venous or arterial catheterization in this species.

  4. Intrahepatic portosystemic venous shunt: diagnosis by color Doppler imaging.

    PubMed

    Kudo, M; Tomita, S; Tochio, H; Minowa, K; Todo, A

    1993-05-01

    Intrahepatic portosystemic venous shunt is a rare clinical entity; only 33 such cases have been reported. It may be congenital, or secondary to portal hypertension. Five patients with this disorder are presented, each of whom was diagnosed by color Doppler imaging, including waveform spectral analysis. One patient with clinical evidence of cirrhosis and portal hypertension had episodes of hepatic encephalopathy and elevated blood levels of ammonia. This patient had a large tubular shunt between the posterior branch of the portal vein and the inferior vena cava. Shunts of this type are considered to be collateral pathways which develop in the hepatic parenchyma as a result of portal hypertension. The other four patients had no evidence of liver disease, and all four evidenced an aneurysmal portohepatic venous shunt within the liver parenchyma. Shunts of this type are considered congenital. The diagnosis of intrahepatic portosystemic venous shunts was established by color Doppler imaging, which demonstrated a direct communication of color flow signals between the portal vein and hepatic vein, in addition to the characterization of the Doppler spectrum at each sampling point from a continuous waveform signal (portal vein) to a turbulent signal (aneurysmal cavity), and finally, to a biphasic waveform signal (hepatic vein). As demonstrated by the five patients, color Doppler imaging is useful in the diagnosis of an intrahepatic portosystemic hepatic venous shunt, and the measurement of shunt ratio may be useful in the follow-up and determining the therapeutic option.

  5. Effect of TGF-beta1 on MMP/TIMP and TGF-beta1 receptors in great saphenous veins and its significance on chronic venous insufficiency.

    PubMed

    Serralheiro, Pedro; Cairrão, Elisa; Maia, Cláudio J; João, Marina; Almeida, Carlos M Costa; Verde, Ignacio

    2017-06-01

    Objectives Transforming growth factor-beta1 (TGF-β1) may participate in local chronic inflammatory processes in varicose veins and in venous wall structure modifications through regulation of matrix metalloproteinases (MMP) and their inhibitors (tissue inhibitor of metalloproteinase (TIMP)). The aim of this study was to analyze the effect of TGF-β1 in the vein wall, namely on the gene expression of selected MMP, TIMP and TGF-β1 receptors. Methods Healthy vein samples were harvested from eight subjects who underwent coronary bypass graft surgery with great saphenous vein. Each vein sample was divided into two segments, which were cultivated separately in vitro (one of the segments had TGF-β1 added) and then submitted to gene expression analysis. Results In the TGF-β1 supplemented group, there was a general increase in the mean gene expression. Specifically, expression of MMP9, MMP12, TIMP1 and TIMP2 were statistically significant. Conclusion The results of this study demonstrate that the gene expression of MMP9, MMP12, TIMP1 and TIMP2 was influenced by the addition of TGF-β1. These results may be translated to chronic venous insufficiency framework and suggest involvement of TGF-β1 in the vein wall pathology.

  6. Use of Capillary Blood Samples Leads to Higher Parasitemia Estimates and Higher Diagnostic Sensitivity of Microscopic and Molecular Diagnostics of Malaria than Venous Blood Samples.

    PubMed

    Mischlinger, Johannes; Pitzinger, Paul; Veletzky, Luzia; Groger, Mirjam; Zoleko-Manego, Rella; Adegnika, Ayola A; Agnandji, Selidji T; Lell, Bertrand; Kremsner, Peter G; Tannich, Egbert; Mombo-Ngoma, Ghyslain; Mordmüller, Benjamin; Ramharter, Michael

    2018-05-25

    Diagnosis of malaria is usually based on samples of peripheral blood. However, it is unclear whether capillary (CAP) or venous (VEN) blood samples provide better diagnostic performance. Quantitative differences of parasitemia between CAP and VEN blood and diagnostic performance characteristics were investigated. Patients were recruited between September 2015 and February 2016 in Gabon. Light microscopy and qPCR quantified parasitemia of paired CAP and VEN samples, whose preparation followed the exact same methodology. CAP and VEN performance characteristics using microscopy were evaluated against a qPCR gold-standard. Microscopy revealed a median (IQR) parasites/L of 495 (853,243) in CAP and 429 (524,074) in VEN samples manifesting in a +16.6% (p=0.04) higher CAPparasitemia compared with VENparasitemia. Concordantly, qPCR demonstrated that -0.278 (p=0.006) cycles were required for signal detection in CAP samples. CAPsensitivity of microscopy relative to the gold-standard was 81.5% (77.485.6%) versus VENsensitivity of 73.4% (68.878.1%), while CAPspecificity and VENspecificity were 91%. CAPsensitivity and VENsensitivity dropped to 63.3% and 45.9%, respectively for a sub-population of low-level parasitemias while specificities were 92%. CAP sampling leads to higher parasitemias compared to VEN sampling and improves diagnostic sensitivity. These findings may have important implications for routine diagnostics, research and elimination campaigns of malaria.

  7. Dried venous blood samples for the detection and quantification of measles IgG using a commercial enzyme immunoassay.

    PubMed Central

    Riddell, Michaela A.; Byrnes, Graham B.; Leydon, Jennie A.; Kelly, Heath A.

    2003-01-01

    OBJECTIVES: To determine whether samples of dried venous blood (DVB) were an acceptable alternative to serum for detecting measles-specific IgG in a commercial enzyme immunoassay. METHODS: Paired samples of serum and DVB were collected from 98 suspected cases of measles and 1153 schoolchildren in Victoria, Australia. All samples were tested using the Dade Behring Enzygnost Anti-Measles-Virus/IgG immunoassay. DVB samples were eluted using either the sample buffer provided with the kit or 5% dry milk powder in phosphate-buffered saline-Tween 20. FINDINGS: DVB samples eluted by sample buffer showed significantly better linear correlation to the serum samples than did DVB samples eluted in 5% dry milk in phosphate-buffered saline-Tween 20. To improve the comparability of serum and DVB samples an adjustment factor of 1.28 was applied to the optical density (OD) values of DVB. This adjustment also enabled quantification of the titre of measles IgG in mIU/ml directly from the OD value using the alpha calculation as specified by the kit protocol. For DVB samples stored for less than six months at 4 degrees C, the assay showed an overall sensitivity of 98.4% and a specificity of 97.2% compared with the results of serum testing. CONCLUSION: These results illustrate the potential for DVB samples to be widely used with the Dade Behring enzyme immunoassay system for determining the immunity of the individual and the population to the measles virus. PMID:14758429

  8. Evaluation of laser speckle contrast imaging as an intrinsic method to monitor blood brain barrier integrity

    PubMed Central

    Dufour, Suzie; Atchia, Yaaseen; Gad, Raanan; Ringuette, Dene; Sigal, Iliya; Levi, Ofer

    2013-01-01

    The integrity of the blood brain barrier (BBB) can contribute to the development of many brain disorders. We evaluate laser speckle contrast imaging (LSCI) as an intrinsic modality for monitoring BBB disruptions through simultaneous fluorescence and LSCI with vertical cavity surface emitting lasers (VCSELs). We demonstrated that drug-induced BBB opening was associated with a relative change of the arterial and venous blood velocities. Cross-sectional flow velocity ratio (veins/arteries) decreased significantly in rats treated with BBB-opening drugs, ≤0.81 of initial values. PMID:24156049

  9. Accuracy of Human and Veterinary Point-of-Care Glucometers for Use in Rhesus Macaques (Macaca mulatta), Sooty Mangabeys (Cercocebus atys), and Chimpanzees (Pan troglodytes).

    PubMed

    Clemmons, Elizabeth A; Stovall, Melissa I; Owens, Devon C; Scott, Jessica A; Jones-Wilkes, Amelia C; Kempf, Doty J; Ethun, Kelly F

    2016-01-01

    Handheld, point-of-care glucometers are commonly used in NHP for clinical and research purposes, but whether these devices are appropriate for use in NHP is unknown. Other animal studies indicate that glucometers should be species-specific, given differences in glucose distribution between RBC and plasma; in addition, Hct and sampling site (venous compared with capillary) influence glucometer readings. Therefore, we compared the accuracy of 2 human and 2 veterinary glucometers at various Hct ranges in rhesus macaques (Macaca mulatta), sooty mangabeys (Cercocebus atys), and chimpanzees (Pan troglodytes) with that of standard laboratory glucose analysis. Subsequent analyses assessed the effect of hypoglycemia, hyperglycemia, and sampling site on glucometer accuracy. The veterinary glucometers overestimated blood glucose (BG) values in all species by 26 to 75 mg/dL. The mean difference between the human glucometers and the laboratory analyzer was 7 mg/dL or less in all species. The human glucometers overestimated BG in hypoglycemic mangabeys by 4 mg/dL and underestimated BG in hyperglycemic mangabeys by 11 mg/dL; similar patterns occurred in rhesus macaques. Hct did not affect glucometer accuracy, but all samples were within the range at which glucometers generally are accurate in humans. BG values were significantly lower in venous than capillary samples. The current findings show that veterinary glucometers intended for companion-animal species are inappropriate for use in the studied NHP species, whereas the human glucometers showed clinically acceptable accuracy in all 3 species. Finally, potential differences between venous and capillary BG values should be considered when comparing and evaluating results.

  10. Inadequacy of Plasma Acyclovir Levels at Delivery in Patients with Genital Herpes Receiving Oral Acyclovir Suppressive Therapy in Late Pregnancy

    PubMed Central

    Leung, Daniel T.; Henning, Paul A.; Wagner, Emily C.; Blasig, Audrey; Wald, Anna; Sacks, Stephen L.; Corey, Lawrence; Money, Deborah M.

    2009-01-01

    Objective: Acyclovir therapy in late pregnancy among women with recurrent genital herpes is effective in decreasing genital lesion frequency and subclinical viral shedding rates at delivery, thereby decreasing the need for caesarean delivery. Despite good adherence and increased dosing schedules, breakthrough lesions and viral shedding are still observed in some women at or near delivery. Anecdotal data suggests that low levels of HSV replication at delivery may result in transmission to the neonate. Therefore, defining optimal acyclovir dosing during labor and delivery is warranted. Our objectives were to determine actual acyclovir levels at delivery, and explore associations between acyclovir levels, duration of labour and time since last acyclovir dose. Methods: Twenty-seven patients were prescribed oral acyclovir 400 mg three times daily from 36 weeks gestation. Cord blood (venous and arterial) and maternal venous blood samples were collected at delivery, and acyclovir levels measured using capillary electrophoresis. Correlations between duration of labour and time since last acyclovir dose with acyclovir blood levels were calculated. Results: Acyclovir levels were below the published mean steady-state trough value (180 ng/ml) in 52% of venous cord, 55% of arterial cord, and 36% of maternal samples. There was a significant inverse correlation between time since last dose and venous cord (rs19=−0.57, p<0.015), arterial cord (rs16=−0.63, p<0.01), and maternal acyclovir levels (r10=−0.69, p<0.03). Conclusions: Oral dosing of acyclovir in late pregnancy may result in insufficient levels at delivery to prevent viral shedding. Alternative approaches should evaluate dosing through labor, perhaps intravenously, and its effect on viral shedding. PMID:20085679

  11. Mixed venous oxygen saturation monitoring revisited: thoughts for critical care nursing practice.

    PubMed

    Christensen, Martin

    2012-05-01

    Less invasive methods of determining cardiac output are now readily available. Using indicator dilution technique, for example has made it easier to continuously measure cardiac output because it uses the existing intra-arterial line. Therefore gone is the need for a pulmonary artery floatation catheter and with it the ability to measure left atrial and left ventricular work indices as well the ability to monitor and measure a mixed venous saturation (SvO(2)). The aim of this paper is to put forward the notion that SvO(2) provides valuable information about oxygen consumption and venous reserve; important measures in the critically ill to ensure oxygen supply meets cellular demand. In an attempt to portray this, a simplified example of the septic patient is offered to highlight the changing pathophysiological sequelae of the inflammatory process and its importance for monitoring SvO(2). SvO(2) monitoring, it could be argued, provides the gold standard for assessing arterial and venous oxygen indices in the critically ill. For the bedside ICU nurse the plethora of information inherent in SvO(2) monitoring could provide them with important data that will assist in averting potential problems with oxygen delivery and consumption. However, it has been suggested that central venous saturation (ScvO(2)) might be an attractive alternative to SvO(2) because of its less invasiveness and ease of obtaining a sample for analysis. There are problems with this approach and these are to do with where the catheter tip is sited and the nature of the venous admixture at this site. Studies have shown that ScvO(2) is less accurate than SvO(2) and should not be used as a sole guiding variable for decision-making. These studies have demonstrated that there is an unacceptably wide range in variance between ScvO(2) and SvO(2) and this is dependent on the presenting disease, in some cases SvO(2) will be significantly lower than ScvO(2). Whilst newer technologies have been developed to continuously measure cardiac output, SvO(2) monitoring is still an important adjunct to clinical decision-making in the ICU. Given the information that it provides, seeking alternatives such as ScvO(2) or blood samples obtained from femorally placed central venous lines, can unnecessarily lead to inappropriate treatment being given or withheld. Instead when using ScvO(2), trending of this variable should provide clinical determinates that are useable for the bedside ICU nurse, remembering that in most conditions SvO(2) will be approximately 16% lower. Copyright © 2011 Australian College of Critical Care Nurses Ltd. Published by Elsevier Ltd. All rights reserved.

  12. Venous Sampling

    MedlinePlus

    ... on an outpatient basis. You will be positioned on the examining table. You may be connected to monitors that track your heart rate, blood pressure and pulse during the procedure. A nurse or technologist will insert an intravenous (IV) line into a ...

  13. Measurement of central venous pressure and determination of hormones in blood serum during weightlessness

    NASA Technical Reports Server (NTRS)

    Kirsch, K.

    1981-01-01

    A Spacelab experiment is described which proposes to obtain data on the degree of engorgement of the cephalad circulation during weightlessness by recording central venous pressure. Of practical importance is the question of how close the astronauts are to pulmonary edema and whether the pressure falls toward normal during the time of the mission. Another experiment to investigate deviations from normal fluid and mineral metabolism, possibly initiated by the central engorgement of the low pressure system, is discussed. Hormones responsible for the control of water and mineral balance (vasopressin, catecholamines, renin, aldosterone, corticosteroids, and prostaglandin E1) will be analyzed from blood samples.

  14. Making the invisible visible: near-infrared spectroscopy and phlebotomy in children.

    PubMed

    Strehle, Eugen-Matthias

    2010-10-01

    Phlebotomy and venous cannulation are the most frequently performed and the most distressing invasive procedures in pediatrics. The aim of this pilot study was to assess whether a novel vein imaging system was advantageous for the identification of superficial veins, thus reducing the number of skin punctures. The Vein Viewer was trialled in 50 children <16 years of age who required venous blood sampling or peripheral venous catheterization as part of their standard clinical care. A questionnaire with 10 questions about their experience of using this equipment was distributed to the pediatric doctors and nurses performing the procedures. During a 9-month period, 38 venipunctures and 12 cannulations were performed in 50 children (mean age 6.67 years). On average, 1.7 puncture attempts per child were necessary. Fifty questionnaires were completed by 11 consultants, 16 registrars, 20 senior house officers, and 3 nurses. Seventy-two percent rated the imaging device as useful, 8% as not useful, and 20% remained neutral. Visibility of the peripheral veins was improved in 76% of children, and the same as with room light in 24%. Near-infrared technology facilitated venipuncture and venous cannulation in a pediatric cohort. Further, controlled trials are required including children of specific age groups and those from ethnic minorities.

  15. Differences in twins: the importance of birth order.

    PubMed

    Young, B K; Suidan, J; Antoine, C; Silverman, F; Lustig, I; Wasserman, J

    1985-04-01

    Despite the clinical impression that firstborn twins do better than second-born twins, recent reports have shown no difference in perinatal mortality between them. In order to evaluate differences in twins, more sensitive means than perinatal deaths are necessary. This study examines differences between 80 firstborn and second-born twin pairs with respect to Apgar score, umbilical venous and arterial blood gas, and acid-base data. The umbilical venous and arterial blood PO2, PCO2, base deficit, pH, and lactic acid concentration were measured in paired samples and compared with the paired t test and chi 2 when applicable. Statistically significant differences favoring twin A, the firstborn, were found in 1-minute Apgar score, umbilical venous pH, PO2, and PCO2, and umbilical arterial PO2. The other factors in umbilical venous and arterial blood did not show statistically significant differences. When these parameters were examined with respect to route of delivery, monochorionic and dichorionic twins, interval between twins, and vertex twins only, with the possible effects of malpresentation eliminated, the results persistently favored the firstborn twin. Thus it is unequivocally demonstrated that there are substantial differences at birth favoring the first twin, despite similar perinatal mortality for both. The data suggest that the second-born twin has potentially greater susceptibility to hypoxia and trauma.

  16. Mechanisms That Modulate Peripheral Oxygen Delivery during Exercise in Heart Failure.

    PubMed

    Kisaka, Tomohiko; Stringer, William W; Koike, Akira; Agostoni, Piergiuseppe; Wasserman, Karlman

    2017-07-01

    Oxygen uptake ([Formula: see text]o 2 ) measured at the mouth, which is equal to the cardiac output (CO) times the arterial-venous oxygen content difference [C(a-v)O 2 ], increases more than 10- to 20-fold in normal subjects during exercise. To achieve this substantial increase in oxygen uptake [[Formula: see text]o 2  = CO × C(a-v)O 2 ] both CO and the arterial-venous difference must simultaneously increase. Although this occurs in normal subjects, patients with heart failure cannot achieve significant increases in cardiac output and must rely primarily on changes in the arterial-venous difference to increase [Formula: see text]o 2 during exercise. Inadequate oxygen delivery to the tissue during exercise in heart failure results in tissue anaerobiosis, lactic acid accumulation, and reduction in exercise tolerance. H + is an important regulatory and feedback mechanism to facilitate additional oxygen delivery to the tissue (Bohr effect) and further aerobic production of ATP when tissue anaerobic metabolism increases the production of lactate (anaerobic threshold). This H + production in the muscle capillary promotes the continued unloading of oxygen (oxyhemoglobin desaturation) while maintaining the muscle capillary Po 2 (Fick principle) at a sufficient level to facilitate aerobic metabolism and overcome the diffusion barriers from capillary to mitochondria ("critical capillary Po 2 ," 15-20 mm Hg). This mechanism is especially important during exercise in heart failure where cardiac output increase is severely constrained. Several compensatory mechanisms facilitate peripheral oxygen delivery during exercise in both normal persons and patients with heart failure.

  17. Changes of loading tensile force-stretch relationships of rabbit mesenteric vein after 21 days of head-down rest

    NASA Astrophysics Data System (ADS)

    Yao, Yong-Jie; Sun, Hui-Pin; Yue, Yong; Sun, Xi-Qing; Wu, Xing-Yu

    Changes of venous compliance may contribute to postflight orthostatic intolerance; however, direct animal studies to address the changes of venous compliance to microgravity have been rare. The purpose of this study was to determine compliance changes of mesenteric veins of rabbits after 21 days of head-down rest (HDR). Twenty-four healthy male New Zealand Rabbits were randomly divided into 21 days of HDR group, horizontal immobilization group (HIG) and control group (Ctrl), with eight in each. Loading tensile force-stretch relationships of mesenteric vein segments were constructed after 21 d HDR. With the increase of loading tensile force, both longitudinal and circumferential stretches of vein samples increased significantly. Under the same loading tensile force, mesenteric vein of the HDR showed significant increase both in circumferential stretch and longitudinal stretches compared to those of Ctrl group and HIG group. These results indicate that, a 21-day simulated weightlessness leads to increase of mesenteric venous compliance.

  18. Association of physical examination with pulmonary artery catheter parameters in acute lung injury.

    PubMed

    Grissom, Colin K; Morris, Alan H; Lanken, Paul N; Ancukiewicz, Marek; Orme, James F; Schoenfeld, David A; Thompson, B Taylor

    2009-10-01

    To correlate physical examination findings, central venous pressure, fluid output, and central venous oxygen saturation with pulmonary artery catheter parameters. Retrospective study. Data from the multicenter Fluid and Catheter Treatment Trial of the National Institutes of Health Acute Respiratory Distress Syndrome Network. Five hundred thirteen patients with acute lung injury randomized to treatment with a pulmonary artery catheter. Correlation of physical examination findings (capillary refill time >2 secs, knee mottling, or cool extremities), central venous pressure, fluid output, and central venous oxygen saturation with parameters from a pulmonary artery catheter. We determined association of baseline physical examination findings and on-study parameters of central venous pressure and central venous oxygen saturation with cardiac index <2.5 L/min/m2 and mixed venous oxygen saturation <60%. We determined correlation of baseline central venous oxygen saturation and mixed venous oxygen saturation and predictive value of a low central venous oxygen saturation for a low mixed venous oxygen saturation. Prevalence of cardiac index <2.5 and mixed venous oxygen saturation <60% was 8.1% and 15.5%, respectively. Baseline presence of all three physical examination findings had low sensitivity (12% and 8%), high specificity (98% and 99%), low positive predictive value (40% and 56%), but high negative predictive value (93% and 86%) for cardiac index <2.5 and mixed venous oxygen saturation <60%, respectively. Central venous oxygen saturation <70% predicted a mixed venous oxygen saturation <60% with a sensitivity 84%,specificity 70%, positive predictive value 31%, and negative predictive value of 96%. Low cardiac index correlated with cool extremities, high central venous pressure, and low 24-hr fluid output; and low mixed venous oxygen saturation correlated with knee mottling and high central venous pressure, but these correlations were not found to be clinically useful. In this subset of patients with acute lung injury, there is a high prior probability that cardiac index and mixed venous oxygen saturation are normal and physical examination findings of ineffective circulation are not useful for predicting low cardiac index or mixed venous oxygen saturation. Central venous oxygen saturation <70% does not accurately predict mixed venous oxygen saturation <60%, but a central venous oxygen saturation >or=70% may be useful to exclude mixed venous oxygen saturation <60%.

  19. Comparison of C-arm computed tomography and on-site quick cortisol assay for adrenal venous sampling: A retrospective study of 178 patients.

    PubMed

    Chang, Chin-Chen; Lee, Bo-Ching; Chang, Yeun-Chung; Wu, Vin-Cent; Huang, Kuo-How; Liu, Kao-Lang

    2017-12-01

    To compare the performance of on-site quick cortisol assay (QCA) and C-arm computed tomography (CT) assistance on adrenal venous sampling (AVS) without adrenocorticotropic hormone stimulation. The institutional review board at our hospital approved this retrospective study, which included 178 consecutive patients with primary aldosteronism. During AVS, we used C-arm CT to confirm right adrenal cannulation between May 2012 and June 2015 (n = 100) and QCA for bilateral adrenal cannulation between July 2015 and September 2016 (n = 78). Successful AVS required a selectivity index (cortisol adrenal vein /cortisol peripheral ) of ≥ 2.0 bilaterally. The overall success rate of C-arm CT-assisted AVS was 87%, which increased to 97.4% under QCA (P = .013). The procedure time (C-arm CT, 49.5 ± 21.3 min; QCA, 37.5 ± 15.6 min; P < .001) and radiation dose (C-arm CT, 673.9 ± 613.8 mGy; QCA, 346.4 ± 387.8 mGy; P < .001) were also improved. The resampling rate was 16% and 21.8% for C-arm CT and QCA, respectively. The initial success rate of the performing radiologist remained stable during the study period (C-arm CT 75%; QCA, 82.1%, P = .259). QCA might be superior to C-arm CT for improving the performance of AVS. • Adrenal venous sampling (AVS) is a technically challenging procedure. • C-arm CT and quick cortisol assay (QCA) are efficient for assisting AVS. • QCA might outperform C-arm CT in enhancing AVS performance.

  20. Low central venous pressure versus acute normovolemic hemodilution versus conventional fluid management for reducing blood loss in radical retropubic prostatectomy: a randomized controlled trial.

    PubMed

    Habib, Ashraf S; Moul, Judd W; Polascik, Thomas J; Robertson, Cary N; Roche, Anthony M; White, William D; Hill, Stephen E; Nosnick, Israel; Gan, Tong J

    2014-05-01

    To compare acute normovolemic hemodilution versus low central venous pressure strategy versus conventional fluid management in reducing intraoperative estimated blood loss, hematocrit drop and need for blood transfusion in patients undergoing radical retropubic prostatectomy under general anesthesia. Patients undergoing radical retropubic prostatectomy under general anesthesia were randomized to conventional fluid management, acute normovolemic hemodilution or low central venous pressure (≤5 mmHg). Treatment effects on estimated blood loss and hematocrit change were tested in multivariable regression models accounting for surgeon, prostate size, and all two-way interactions. Ninety-two patients completed the study. Estimated blood loss (mean ± SD) was significantly lower with low central venous pressure (706 ± 362 ml) compared to acute normovolemic hemodilution (1103 ± 635 ml) and conventional (1051 ± 714 ml) groups (p = 0.0134). There was no difference between the groups in need for blood transfusion, or hematocrit drop from preoperative values. The multivariate model predicting estimated blood loss showed a significant effect of treatment (p = 0.0028) and prostate size (p = 0.0323), accounting for surgeon (p = 0.0013). In the model predicting hematocrit change, accounting for surgeon difference (p = 0.0037), the treatment effect depended on prostate size (p = 0.0007) with the slope of low central venous pressure differing from the other two groups. Hematocrit was predicted to drop more with increased prostate size in acute normovolemic hemodilution and conventional groups but not with low central venous pressure. Limitations include the inability to blind providers to group assignment, possible variability between providers in estimation of blood loss, and the relatively small sample size that was not powered to detect differences between the groups in need for blood transfusion. Maintaining low central venous pressure reduced estimated blood loss compared to conventional fluid management and acute normovolemic hemodilution in patients undergoing radical retropubic prostatectomy but there was no difference in allogeneic blood transfusion between the groups.

  1. Initial Australasian experience with portal-enteric drainage in simultaneous pancreas-kidney transplantation.

    PubMed

    Kave, Ben; Yii, Ming; Bell, Roger; Kanellis, John; Scott, David; Saunder, Alan

    2010-10-01

    Pancreas-kidney transplantation is currently the most effective method to re-establish euglycaemia in insulin-dependent diabetics with associated renal failure. The standard technique employed has been bladder drainage of exocrine secretions coupled with systemic venous drainage ('systemic-bladder' (SB) drainage). The more physiological technique, enteric exocrine with portal venous drainage ('portal-enteric' (PE) drainage), has been utilized sparingly in the past as a result of fears of technical complications. This paper compares the Monash Medical Centre experience with both techniques. A total of 68 simultaneous pancreas-kidney transplantations were performed at Monash Medical Centre from 1991 until 2004. The first 37 received SB drainage. Since March 2001, 27 have received PE drainage. This retrospective study compared the SB group (n= 37) with the PE group (n= 27), with a 2-year follow-up, examining a number of surgical outcomes. Two-year patient (94.3 versus 96.0%), kidney (89.2 versus 85.2%), pancreas (77.9 versus 71.4%) and event-free (73.0 versus 67.7%) survivals were all similar between the SB and PE groups, respectively. Although surgery took longer in PE subjects (4 h : 47 min ± 0:48 versus 5 h : 16 min ± 1:00; P= 0.045), less intraoperative transfusions were required (1.3 ± 1.43 versus 0.52 ± 0.90; P= 0.024). Length of hospital stay and time to insulin independence were similar. Pancreas graft thrombosis rates were similar (10.8% SB versus 7.4% PE, P= 0.497). PE drainage is a safe and viable method for pancreas transplantation, which can be performed with excellent outcomes. An increased rate of complications with PE drainage has not been demonstrated in this series. © 2009 The Authors. ANZ Journal of Surgery © 2009 Royal Australasian College of Surgeons.

  2. Evaluation of thromboembolic events in cancer patients receiving bevacizumab according to the Japanese Adverse Drug Event Report database.

    PubMed

    Matsumura, Chikako; Chisaki, Yugo; Sakimoto, Satoko; Sakae, Honoka; Yano, Yoshitaka

    2018-01-01

    Purpose We aimed to examine the risk factors, time of onset, incidence rates, and outcomes of thromboembolic events induced by bevacizumab in patients with cancer using the Japanese Adverse Drug Event Report (JADER) database of the Pharmaceuticals and Medical Devices Agency. Methods Adverse event data recorded in the JADER database between January 2004 and January 2015 were used. After screening the data using the generic drug name bevacizumab, patient data were classified into two groups by age and five groups by cancer type. The histories of disorders were also categorized. Arterial thromboembolic event and venous thromboembolic event were classified as "favorable" or "unfavorable" outcomes. Results In total, 6076 patients were reported to have developed adverse events during the sample period, of which 233 and 453 developed arterial thromboembolic event and venous thromboembolic event, respectively. Logistic analysis suggested that the presence of cancer was a significant risk factor for both arterial thromboembolic event and venous thromboembolic event. Age (≥70 years), histories of either hypertension or diabetes mellitus were also risk factors for arterial thromboembolic event. Median cumulative times of onset for arterial thromboembolic event and venous thromboembolic event were 60 and 80 days, respectively, and were not significantly different by the log-rank test. By the chi-square test, the rate of unfavorable outcomes was found to be higher after developing arterial thromboembolic event than after venous thromboembolic event. Conclusion Thromboembolism is a leading cause of mortality in patients with cancer. Patients should be monitored for the symptoms of thromboembolic events right from the initial stages of bevacizumab treatment.

  3. Persistent staphylococcal bacteremia in an intravenous drug abuser.

    PubMed

    Barg, N L; Supena, R B; Fekety, R

    1986-02-01

    A patient with methicillin-resistant Staphylococcus aureus bacteremia received vancomycin (MIC = 0.8 microgram/ml, MBC = 15 micrograms/ml) and heparin simultaneously through the same intravenous line to treat a septic deep venous thrombosis. Bacteremia persisted for 7 days. Bacteremia terminated when the simultaneous infusion of heparin and vancomycin through the same line was stopped. This suggested that an interaction between vancomycin and heparin may have occurred, which resulted in a reduction in vancomycin activity. To test for such an interaction, mixtures of heparin and vancomycin in various concentrations were made and tested for antimicrobial activity against the organisms in the patient. A precipitate formed at the concentrations achieved in the intravenous lines, and when the vancomycin concentrations were measured by bioassay, a 50 to 60% reduction in activity was noted. In contrast, when these solutions were prepared and mixed at microgram concentrations, a precipitate was no longer observed, and antimicrobial activity was not reduced. Heparin appeared to interact unfavorably with vancomycin at the concentrations in the intravenous lines when these drugs were administered simultaneously to patients. This may be the cause of poor therapeutic responses to vancomycin in some patients, especially those infected with tolerant organisms.

  4. Effectiveness of a patient education plan on knowledge of post-op venous thromboembolism survival skills.

    PubMed

    Green, Julie; Bernhofer, Esther I

    2018-04-01

    To investigate the effectiveness of a multimethod venous thromboembolism prevention patient education plan on participants' knowledge retention. A potential complication of surgery requiring general anaesthesia, worldwide, is the development of life-threatening venous thromboembolism. Patients need education on preventing, recognising and immediately responding to a suspected thromboembolism. Written instructional materials given to patients at discharge may be inadequate. A randomised controlled trial. Setting was multiple general surgery units at a large Midwestern United States academic medical centre. Sample included patients recovering from surgery with general anaesthesia: (N = 66), 68% female, 34 = experimental, 32 = usual care. Prior to discharge, participants in the experimental group were given a multimethod venous thromboembolism prevention education plan including a video, pamphlet and verbal instruction; control group received usual instructional pamphlet. Both groups received a knowledge test immediately before instruction. Two weeks following discharge, a phone call was made to participants to complete the postinstruction test. The relevant EQUATOR guideline, CONSORT checklist, was used for reporting this study. There were no statistically significant differences in age, gender, race, length of stay, surgery and history of venous thromboembolism among participants and group or test score results. No statistically significant difference in postinstruction score was found between groups. However, there was a trend in greater perception of importance in all groups and higher knowledge scores in the experimental group, with the percentage of participants in the experimental group answering all questions correctly rising from 38.2% correct to 73.5% correct. Teaching patients the importance of knowing venous thromboembolism signs and preventive/survival skills is potentially life-saving and nurses must know the importance of using the most effective methods for the learning needs of their patients. Further research including different education methods and testing is suggested. © 2018 John Wiley & Sons Ltd.

  5. [Sequence of venous blood flow alterations in patients after recently endured acute thrombosis of lower-limb deep veins based on the findings of ultrasonographic duplex scanning].

    PubMed

    Tarkovskiĭ, A A; Zudin, A M; Aleksandrova, E S

    2009-01-01

    This study was undertaken to investigate the sequence of alterations in the venous blood flow to have occurred within the time frame of one year after sustained acute thrombosis of the lower-limb deep veins, which was carried out using the standard technique of ultrasonographic duplex scanning. A total of thirty-two 24-to-62-year-old patients presenting with newly onset acute phlebothrombosis were followed up. All the patients were sequentially examined at 2 days, 3 weeks, 3 months, 6 months and 12 months after the manifestation of the initial clinical signs of the disease. Amongst the parameters to determine were the patency of the deep veins and the condition of the valvular apparatus of the deep, superficial and communicant veins. According to the obtained findings, it was as early as at the first stage of the phlebohaemodynamic alterations after the endured thrombosis, i. e., during the acute period of the disease, that seven (21.9%) patients were found to have developed valvular insufficiency of the communicant veins of the cms, manifesting itself in the formation of a horizontal veno-venous reflux, and 6 months later, these events were observed to have occurred in all the patients examined (100%). Afterwards, the second stage of the phlebohaemodynamic alterations was, simultaneously with the process of recanalization of the thrombotic masses in the deep veins, specifically characterized by the formation of valvular insufficiency of the latter, manifesting itself in the form of the development of a deep vertical veno-venous reflux, which was revealed at month six after the onset of the disease in 56.3% of the examined subjects, to be then observed after 12 months in 93.8% of the patients involved. Recanalization of thrombotic masses was noted to commence 3 months after the onset of thrombosis in twelve (37.5%) patients, and after 12 months it was seen to ensue in all the patients (100%), eventually ending in complete restoration of the patency of the affected veins (to have occurred in 25% of the cases). Of special interest was the finding that insufficiency of the ostial valve of the great saphenous vein, manifesting itself by a superficial vertical veno-venous reflux, was revealed only in two (6.25%) patients examined 12 months after the onset of the disease, which may be regarded as the third stage of the phlebohaemodynamic alterations. That low prevalence and no evidence of varicose transformation of superficial veins appear to suggest an important part they play in compensation of the venous outflow from the extremity affected.

  6. The use of intermittent and continuous recordings of jugular venous bulb oxygen saturation in the unconscious patient.

    PubMed

    Garlick, R; Bihari, D

    1987-01-01

    Monitoring clinical signs in unconscious patients provides only late information about cerebral deterioration. Ischaemia and hypoxia are the mechanisms of much of the damage. Cerebral blood flow (CBF) measurements provide direct evidence of ischaemia but are intermittent values for what may be an unstable situation. Continuous recordings of CBF and oxygenation are more likely to reveal harmful tendencies to ischaemia and hypoxia at an early stage than intermittent readings. We report our experience with intermittent and also continuous recording of the jugular venous bulb oxygen saturation (JVO2Sat) obtained by fibreoptic oximetry in a group of 10 head injured and 7 septic patients. Simultaneous measurements of CBF by an isotopic xenon clearance method were also made. The JVO2Sat has been suggested to be a reliable indicator of cerebral oxygenation, a low value being indicative of ischaemia. We discuss whether our findings support this statement. There are also variations in JVO2Sat with mean arterial blood pressure and intracranial pressure. These variations have important implications in the interpretation that can be made of one single value of JVO2Sat.

  7. Texture analysis of common renal masses in multiple MR sequences for prediction of pathology

    NASA Astrophysics Data System (ADS)

    Hoang, Uyen N.; Malayeri, Ashkan A.; Lay, Nathan S.; Summers, Ronald M.; Yao, Jianhua

    2017-03-01

    This pilot study performs texture analysis on multiple magnetic resonance (MR) images of common renal masses for differentiation of renal cell carcinoma (RCC). Bounding boxes are drawn around each mass on one axial slice in T1 delayed sequence to use for feature extraction and classification. All sequences (T1 delayed, venous, arterial, pre-contrast phases, T2, and T2 fat saturated sequences) are co-registered and texture features are extracted from each sequence simultaneously. Random forest is used to construct models to classify lesions on 96 normal regions, 87 clear cell RCCs, 8 papillary RCCs, and 21 renal oncocytomas; ground truths are verified through pathology reports. The highest performance is seen in random forest model when data from all sequences are used in conjunction, achieving an overall classification accuracy of 83.7%. When using data from one single sequence, the overall accuracies achieved for T1 delayed, venous, arterial, and pre-contrast phase, T2, and T2 fat saturated were 79.1%, 70.5%, 56.2%, 61.0%, 60.0%, and 44.8%, respectively. This demonstrates promising results of utilizing intensity information from multiple MR sequences for accurate classification of renal masses.

  8. Compact dual-mode diffuse optical system for blood perfusion monitoring in a porcine model of microvascular tissue flaps

    NASA Astrophysics Data System (ADS)

    Lee, Seung Yup; Pakela, Julia M.; Helton, Michael C.; Vishwanath, Karthik; Chung, Yooree G.; Kolodziejski, Noah J.; Stapels, Christopher J.; McAdams, Daniel R.; Fernandez, Daniel E.; Christian, James F.; O'Reilly, Jameson; Farkas, Dana; Ward, Brent B.; Feinberg, Stephen E.; Mycek, Mary-Ann

    2017-12-01

    In reconstructive surgery, the ability to detect blood flow interruptions to grafted tissue represents a critical step in preventing postsurgical complications. We have developed and pilot tested a compact, fiber-based device that combines two complimentary modalities-diffuse correlation spectroscopy (DCS) and diffuse reflectance spectroscopy-to quantitatively monitor blood perfusion. We present a proof-of-concept study on an in vivo porcine model (n=8). With a controllable arterial blood flow supply, occlusion studies (n=4) were performed on surgically isolated free flaps while the device simultaneously monitored blood flow through the supplying artery as well as flap perfusion from three orientations: the distal side of the flap and two transdermal channels. Further studies featuring long-term monitoring, arterial failure simulations, and venous failure simulations were performed on flaps that had undergone an anastomosis procedure (n=4). Additionally, benchtop verification of the DCS system was performed on liquid flow phantoms. Data revealed relationships between diffuse optical measures and state of occlusion as well as the ability to detect arterial and venous compromise. The compact construction of the device, along with its noninvasive and quantitative nature, would make this technology suitable for clinical translation.

  9. Duration and Adverse Events of Non-cuffed Catheter in Patients With Hemodialysis

    ClinicalTrials.gov

    2014-10-09

    Renal Failure Chronic Requiring Hemodialysis; Central Venous Catheterization; Inadequate Hemodialysis Blood Flow; Venous Stenosis; Venous Thrombosis; Infection Due to Central Venous Catheter; Central Venous Catheter Thrombosis

  10. The effect of vein repair on the risk of venous thromboembolic events: a review of more than 100 traumatic military venous injuries.

    PubMed

    Quan, Reagan W; Gillespie, David L; Stuart, Rory P; Chang, Audrey S; Whittaker, David R; Fox, Charles J

    2008-03-01

    The management of venous trauma remains controversial. Critics of venous repair have cited an increased incidence of associated venous thromboembolic events with this management. We analyzed the current treatment of wartime venous injuries in United States military personnel in an effort to answer this question. From December 1, 2001, to October 31, 2005, all United States casualties with named venous injuries were evaluated. A retrospective review of a clinical database was performed on demographics, mechanism of injury, associated injuries, treatment, outcomes, and venous thromboembolic events. Data were analyzed using the Fisher exact test, analysis of variance, and logarithmic transformation. During this 5-year period, 82 patients sustained 103 named venous injuries due to combat operations. All patients were male, with an average age of 27.9 years (range, 20.3-58.3 years). Blast injuries accounted for 54 venous injuries (65.9%), gunshot wounds for 25 (30.5%), and motor vehicle accidents for 3 (3.6%). The venous injury was isolated in 28 patients (34.1%), and 16 (19.5%) had multiple venous injuries. The venous injury in two patients was associated with acute phlegmasia, with fractures in 33 (40.2%), and 22 (28.1%) sustained neurologic deficits. Venous injuries were treated by ligation in 65 patients (63.1%) and by open surgical repair in 38 (36.9%). Postoperative extremity edema occurred in all patients irrespective of method of management. Thrombosis after venous repair occurred in six of the 38 cases (15.8%). Pulmonary emboli developed in three patients, one after open repair and two after ligation (P > .99). In the largest review of military venous trauma in more than three decades, we found no difference in the incidence of venous thromboembolic complications between venous injuries managed by open repair vs ligation. Blast injuries of the extremities have caused most of the venous injuries. Ligation is the most common modality of treatment in combat zones. Long-term morbidity associated with venous injuries and their management will be assessed in future follow-up studies.

  11. Comprehensive assessment of cavernosography with 320-row dynamic volume CT versus conventional cavernosography in erectile dysfunction patients caused by venous leakage

    PubMed Central

    Pan, Yu-Ning; Tang, Yi-Fan; Zhang, Jie; Wang, Guo-Yao; Huang, Qiu-Li

    2017-01-01

    The present study aims to investigate and compare the diagnostic and prognostic value of cavernosography with 320-row dynamic volume computed tomography (DVCT) versus conventional cavernosography in men with erectile dysfunction (ED) caused by venous leakage. A total of 174 patients diagnosed with ED were enrolled and received cavernosography with 320-row DVCT (DVCT group) and conventional cavernosography scans (control group) respectively. The diagnosis, complications, and prognosis of patients were evaluated. The DVCT group provided high-resolution images with less processing and testing time, as well as lowered radiological agent and contrast agent compared with the control group. In the DVCT group, 89 patients who were diagnosed with venous ED had six various venous leakage, namely superficial venous leakage, profundus venous leakage, the mixed type, cavernosal venous leakage, crural venous leakage, and also venous leakage between the penis and urethra cavernosum (9, 21, 32, 6, 18, and 3 cases respectively). Similarly, 74 patients out of the 81 who suffered from venous ED were classified to have superficial venous leakage (11), profundus venous leakage (14), the mixed type venous leakage (26), and middle venous leakage (23). Six out of 25 patients in the DVCT group, had improvements in ED while the remaining 19 achieved full erectile function recovery with no penile fibrosis and erectile pain. Cavernosography with 320-row DVCT is a reliable system that can be used to diagnose ED caused by venous leakage. This is especially useful in accurately determining the type of venous and allows for a better prognosis and direction of treatment. PMID:28424371

  12. Iliac Vein Interrogation Augments Venous Ulcer Healing in Patients Who Have Failed Standard Compression Therapy along with Pathological Venous Closure.

    PubMed

    Mousa, Albeir Y; Broce, Mike; Yacoub, Michael; AbuRahma, Ali F

    2016-07-01

    Treatment of venous ulcers is demanding for patients, as well as clinicians, and the investigation of underlying venous hypertension is the cornerstone of therapy. We propose that occult iliac vein stenosis should be ruled out by iliac vein interrogation (IVI) in patients with advanced venous stasis. We conducted a systematic retrospective analysis of a consecutive series of patients who presented with CEAP (clinical, etiological, anatomical, and pathophysiological) 6 venous disease. All patients had great saphenous vein ablation, compressive treatment, wound care (including Unna boot compression), and perforator closure using ablation therapy. Iliac vein stenosis was defined as ≥50% stenosis in cross-sectional surface area on intravascular ultrasound. Primary outcomes include time of venous ulcer healing and/or measurable change in the Venous Clinical Severity Score. Twenty-two patients with CEAP 6 venous disease met the inclusion criteria (active ulcers >1.5 cm in diameter). The average age and body mass index were 62.2 ± 9.2 years and 41.7 ± 16.7, respectively. The majority were female (72.7%) with common comorbidities, such as hyperlipidemia (54.5%), hypertension (36.4%), and diabetes mellitus (27.3%). Twenty-nine ulcers with an average diameter of 3.4 ± 1.9 cm and a depth of 2.2 ± 0.5 mm were treated. The majority of the ulcers occurred on the left limb (n = 17, 58.6%). Average perforator venous reflux was 3.6 ± 0.8 sec, while common femoral reflux was 1.8 ± 1.6. The majority (n = 19, 64.5%) of the perforator veins were located at the base of the ulcer, while the remainder (n = 10, 34.5%) were within 2 cm from the base. Of the 13 patients who underwent IVI, 8 patients (61.5%) had stenosis >50% that was corrected with iliac vein angioplasty and stenting (IVAS). There was a strong trend toward shorter healing time in the IVI group (7.9 ± 9.5 weeks) than for patients in the no iliac vein interrogation (NIVI) group (20.2 ± 15.3 weeks, P = 0.055). The final VCCS score was not significantly different (IVI = 7.9 ± 9.5 vs. NIVI = 10.0 ± 6.5, P = 0.578). However, compared with the NIVI group, the healing time for patients who actually received IVAS was marginally lower (5.8 ± 3.6 weeks, P = 0.075) and final VCCS was significantly lower (2.4 ± 2.9, P = 0.031). Veins that received IVI and IVAS remained patent and the associated ulcers were healed (100%). The small sample size and retrospective design limit the strength of the conclusions but the findings suggest that further studies are needed to define the exact role of IVI including angioplasty/stenting for patients with chronic venous ulcers. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Patterns and Rates of Supplementary Venous Drainage to the Internal Jugular Veins.

    PubMed

    Qureshi, Adnan I; Ishfaq, Muhammad Fawad; Herial, Nabeel A; Khan, Asif A; Suri, M Fareed K

    2016-07-01

    Several studies have found supplemental venous drainage channels in addition to bilateral internal jugular veins for cerebral venous efflux. We performed this study to characterize the supplemental venous outflow patterns in a consecutive series of patients undergoing detailed cerebral angiography with venous phase imaging. The venographic phase of the arteriogram was reviewed to identify and classify supplemental cerebral venous drainage into anterior (cavernous venous sinus draining into pterygoid plexus and retromandibular vein) and posterior drainage pattern. The posterior drainage pattern was further divided into plexiform pattern (with sigmoid venous sinus draining into the paravertebral venous plexus), and solitary vein pattern (dominant single draining deep cervical vein) drainage. The posterior plexiform pattern was further divided into 2 groups: posterior plexiform with or without prominent solitary vein. Supplemental venous drainage was seen ipsilateral to internal jugular vein in 76 (43.7%) of 174 venous drainages (87 patients) analyzed. The patterns were anterior (n = 23, 13.2%), posterior plexiform without prominent solitary vein (n = 40, 23%), posterior plexiform with prominent solitary vein (n = 62, 35.6%), and posterior solitary vein alone (n = 3, 1.7%); occipital emissary veins and/or transosseous veins were seen in 1 supplemental venous drainage. Concurrent ipsilateral anterior and posterior supplemental drainage was seen in 6 of 174 venous drainages analyzed. We provide an assessment of patterns and rates of supplementary venous drainage to internal jugular veins to improve our understanding of anatomical and physiological aspects of cerebral venous drainage. Copyright © 2016 by the American Society of Neuroimaging.

  14. Simultaneous transcatheter closure of intralobar pulmonary sequestration and patent ductus arteriosus in a patient with infantile Scimitar syndrome.

    PubMed

    Aslan, Eyüp; Tanıdır, İbrahim Cansaran; Saygı, Murat; Onan, Sertaç Hanedan; Güzeltaş, Alper

    2015-03-01

    Scimitar syndrome is a rare disease associated with a right lung sequestration vascularised by arteries arising from the abdominal aorta and abnormal venous drainage into the inferior vena cava. The infantile form is generally presented with severe heart failure, pulmonary hypertension and respiratory distress. It may be associated with various intracardiac defects, including atrial septal defects, ventricular septal defects, patent ductus arteriosus or more complicated structural congenital heart defects. Here, we present a 2-month-old girl with Scimitar syndrome whose pulmonary arterial pressure decreased after transcatheter patent ductus arteriosus closure and embolization of the anomalous systemic arterial supply.

  15. The possibility for use of venous flaps in plastic surgery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baytinger, V. F., E-mail: baitinger@mail.tomsknet.ru; Kurochkina, O. S., E-mail: kurochkinaos@yandex.ru; Selianinov, K. V.

    2015-11-17

    The use of venous flaps is controversial. The mechanism of perfusion of venous flaps is still not fully understood. The research was conducted on 56 white rats. In our experimental work we studied two different models of venous flaps: pedicled venous flap (PVF) and pedicled arterialized venous flap (PAVF). Our results showed that postoperative congestion was present in all flaps. However 66.7% of all pedicled venous flaps and 100% of all pedicled arterialized venous flaps eventually survived. Histological examination revealed that postoperatively the blood flow in the skin of the pedicled arterialized venous flap became «re-reversed» again; there were nomore » differences between mechanism of survival of venous flaps and other flaps. On the 7-14th day in the skin of all flaps were processes of neoangiogenesis and proliferation. Hence the best scenario for the clinical use of venous flaps unfolds when both revascularization and skin coverage are required.« less

  16. Medial gastrocnemius vein aneurysm development after compressive trauma in the knee.

    PubMed

    De Santis, Francesco; Candia, Silvia; Scialpi, Renzo; Piccinin, Alfredo; Bruni, Antonio; Morettini, Giuseppe; Loreni, Giorgio

    2017-06-01

    Objectives Venous aneurysms are uncommon. They can involve both superficial and deep venous systems. We hereby present a unique case of gastrocnemius venous aneurysm developed after compressive knee trauma. Report A large venous aneurysm in the left popliteal fossa was detected by chance in a 44-year-old woman one month after a compressive trauma to the posterior surface of the knee. Magnetic resonance-imaging of the same knee had documented normal venous anatomy one year earlier. The venous aneurysm involved the medial gastrocnemius vein near its confluence in the popliteal vein and was surgically resected. Histopathology evidenced a true venous aneurysm. The patient was discharged under oral anticoagulation for three months. At one year follow-up, neither complications nor new venous aneurysm development was detected. Conclusions An accurate evaluation of the venous system is always mandatory after limb traumas which may lead to post-traumatic venous pseudo-aneurysms, as well as more rarely, true venous aneurysms in the lower extremities.

  17. Venous Return and Clinical Hemodynamics: How the Body Works during Acute Hemorrhage

    ERIC Educational Resources Information Center

    Shen, Tao; Baker, Keith

    2015-01-01

    Venous return is a major determinant of cardiac output. Adjustments within the venous system are critical for maintaining venous pressure during loss in circulating volume. This article reviews two factors that are thought to enable the venous system to compensate during acute hemorrhage: 1) changes in venous elastance and 2) mobilization of…

  18. An umbilical venous catheter complication presented as acute abdomen: case report.

    PubMed

    Oztan, Mustafa O; Ilhan, Ozkan; Abay, Elif; Koyluoglu, Gokhan

    2016-12-01

    Umbilical venous catheterization has become a widely accepted intravenous route for premature babies. These catheters allow administration of parenteral nutrition and medication and facilitate blood sampling. Besides these benefits, they also have significant potential complications like portal vein thrombosis, infection, vascular or hepatic injury, arrhythmia and sepsis. One of the rare but important complication is extravasation of the fluids due to misplacement of the catheter. The typical symptoms of this condition are sudden deterioration, hepatic enlargement, hematocrit drop, hypotension and abdominal distension. We herein present a premature newborn with unusual acute abdomen findings suggesting a surgical pathology after the extravasation of total parenteral nutrition into the abdomen. Sociedad Argentina de Pediatría.

  19. To shunt or not to shunt? An experimental study comparing temporary vascular shunts and venous ligation as damage control techniques for vascular trauma.

    PubMed

    Marinho de Oliveira Góes Junior, Adenauer; de Campos Vieira Abib, Simone; de Seixas Alves, Maria Teresa; Venerando da Silva Ferreira, Paulo Sérgio; Carvalho de Andrade, Mariseth

    2014-04-01

    To evaluate vascular flow through temporary vascular shunts inserted into peripheral arteries and veins and the repercussion, on the arterial perfusion, of venous ligation and venous shunt insertion in an experimental model for damage control. Experimental study in pigs. Animals were distributed in 5 groups: group 1, right external iliac artery (EIA) shunting and right external iliac vein (EIV) ligation; group 2, right EIA shunting and right EIV shunting; group 3, right EIV ligation; group 4, right EIV shunting; group 5, no vascular shunting and no venous ligation. Flowmeters were used to measure vascular flow on right and left external iliac vessels, and blood samples were collected from the EIVs for biochemical analysis. A right anterior limb biopsy was performed before shock. Hemorrhagic shock was induced through the external right jugular vein, until the vascular flow through right iliac external artery shunt or right iliac external vein shunt (group 4) ceased or until the animal's death. After the end of the experiments, biopsies of bilateral hind limb were obtained for histologic analysis. For statistical analysis, Microsoft Office Excel 2007 and BioEstat 5.0 (2007) were used. In the absence of hemorrhagic shock, venous ligation (group 1) was associated with a 38.8% reduction (P < 0.05) and venous shunting with a 28.4% reduction on the vascular flow through the arterial shunt. When associated with hemorrhagic shock, the mean vascular flow on the right EIA was 13 mL/min and on the left EIA was 41.2 mL/min; on group 2, the right EIA flow was 8.5 mL/min and the left EIA flow was 8.1 mL/min. When associated with hemorrhagic shock, the pO2 was 25.8 mm Hg on right EIV and 33.8 mm Hg on the left EIV for group 1 (P < 0.05), whereas for group 2, the pO2 was 22.6 mm Hg on right EIV and 22.8 mm Hg on the left EIV. On group 1, serum potassium was 3.84 mEq/L on the right EIV and 3.96 mEq/L on the left EIV, whereas on group 2, it was 7.1 mEq/L on the right EIV and 5.88 mEq/L on the left EIV (P < 0.05). In the developed experimental model, venous shunting, when compared with venous ligation, offered less resistance to vascular flow through the arterial shunt and allowed a more efficient limb venous drainage than simple vein ligature. Copyright © 2014 Elsevier Inc. All rights reserved.

  20. Venous Shunt Versus Venous Ligation for Vascular Damage Control: The Immunohistochemical Evidence.

    PubMed

    Góes Junior, Adenauer Marinho de Oliveira; Abib, Simone de Campos Vieira; Alves, Maria Teresa de Seixas; Ferreira, Paulo Sérgio Venerando da Silva; Andrade, Mariseth Carvalho de

    2017-05-01

    To evaluate the expression of immunohistochemical markers of tissue ischemia (iNOS, eNOS, and HSP70) in a vascular damage control experimental model to determine if a venous temporary vascular shunt insertion leads to a better limb perfusion when compared with the ligature of the injured vein. Experimental study in male Sus Scrofa weighting 40 Kg. Animals were distributed into 5 groups: group 1 animals were submitted to right external iliac artery (EIA) shunting and right external iliac vein (EIV) ligation; group 2 animals were submitted to right EIA shunting and right EIV shunting; group 3 animals were submitted to right EIV ligation; group 4 animals were submitted to right EIV shunting; group 5 animals were not submitted to vascular shunting or venous ligation. Transonic Systems flowmeters were used to measure vascular flow on right and left external iliac vessels, and i-STAT (Abbot) portable blood analyzer was used for EIVs blood biochemical analysis. An initial baseline register of invasive arterial pressure, iliac vessels flow, and venous blood analysis was performed. Arterial pressure and iliac vessels flow were taken immediately after right iliac vessels shunting or ligation. Then, hemorrhagic shock was induced by continuous 20 mL/min blood withdraw from the external right jugular vein whereas arterial blood pressure and iliac vessels flow registers were taken every 10 min, and blood samples from EIVs were obtained every 30 min until the vascular flow through right EIA (or through the shunt inserted into the right EIV for group 4 animals) became inexistent or until the animal's death. After the end of the experiments, bilateral hind limb's biopsies were obtained for immunohistochemical analysis. Using image editing and analysis software, the expression of iNOS, eNOS, and HSP70 (3 well-known ischemic associated immunohistochemical markers) was assessed. The mean expression of each marker in the right hind limb was compared between groups. For statistical analysis, Microsoft Office Excel 2007 and BioEstat 5.0 (2007) were used. Immunohistochemical analysis showed no difference regarding the iNOS expression; nevertheless, both eNOS and HSP70 expression were statistically more intense (P < 0.05) on group 1 (eNOS = 1.32; HSP70 = 15.05) than on group 2 (eNOS = 0.018; HSP70 = 8.56). The higher expression of eNOS and HSP70 in the right hind limbs of group 1 animals (arterial shunt and venous ligature) than group 2 animals (arterial shunt and venous shunt) suggests that venous ligation is associated with more intense ischemic histological findings than venous shunting. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. Lack of association between venous hemodynamics, venous morphology and the postthrombotic syndrome after upper extremity deep venous thrombosis.

    PubMed

    Czihal, M; Paul, S; Rademacher, A; Bernau, C; Hoffmann, U

    2015-03-01

    To explore the association of the postthrombotic syndrome with venous hemodynamics and morphological abnormalities after upper extremity deep venous thrombosis. Thirty-seven patients with a history of upper extremity deep venous thrombosis treated with anticoagulation alone underwent a single study visit (mean time after diagnosis: 44.4 ± 28.1 months). Presence and severity postthrombotic syndrome were classified according to the modified Villalta score. Venous volume and venous emptying were determined by strain-gauge plethysmography. The arm veins were assessed for postthrombotic abnormalities by ultrasonography. The relationship between postthrombotic syndrome and hemodynamic and morphological sequelae was evaluated using univariate significance tests and Spearman's correlation analysis. Fifteen of 37 patients (40.5%) developed postthrombotic syndrome. Venous volume and venous emptying of the arm affected by upper extremity deep venous thrombosis did not correlate with the Villalta score (rho = 0.17 and 0.19; p = 0.31 and 0.25, respectively). Residual morphological abnormalities, as assessed by ultrasonography, did not differ significantly between patients with and without postthrombotic syndrome (77.3% vs. 86.7%, p = 0.68). Postthrombotic syndrome after upper extremity deep venous thrombosis is not associated with venous hemodynamics or residual morphological abnormalities. © The Author(s) 2013 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  2. A Factor Increasing Venous Contamination on Bolus Chase Three-dimensional Magnetic Resonance Imaging: Charcot Neuroarthropathy.

    PubMed

    Çildağ, Mehmet B; Ertuğrul, Mustafa B; Köseoğlu, Ömer Fk; Armstrong, David G

    2018-01-01

    The study aimed to evaluate the ratio of venous contamination in diabetic cases without foot lesion, with foot lesion and with Charcot neuroarthropathy (CN). Bolus-chase three-dimensional magnetic resonance (MR) of 396 extremities of patients with diabetes mellitus was analyzed, retrospectively. Extremities were divided into three groups as follows: diabetic patients without foot ulcer or Charcot arthropathy (Group A), patients with diabetic foot ulcers (Group B) and patients with CN accompanying diabetic foot ulcers (Group C). Furthermore, amount of venous contamination classified as no venous contamination, mild venous contamination, and severe venous contamination. The relationship between venous contamination and extremity groups was investigated. Severe venous contamination was seen in Group A, Group B, and Group C, 5.6%, 15.2%, and 34.1%, respectively. Statistically significant difference was seen between groups with regard to venous contamination. Venous contamination following bolus chase MR was higher in patients with CN.

  3. Tapping but not massage enhances vasodilation and improves venous palpation of cutaneous veins.

    PubMed

    Ichimura, Mika; Sasaki, Shinsuke; Mori, Masaharu; Ogino, Tetsuya

    2015-01-01

    This paper investigated whether tapping on the median cubital vein or massaging the forearm was more effective in obtaining better venous palpation for venipuncture. Forty healthy volunteers in their twenties were subjected to tapping (10 times in 5 sec) or massage (10 strokes in 20 sec from the wrist to the cubital fossa) under tourniquet inflation on the upper arm. Venous palpation was assessed using the venous palpation score (0-6, with 0 being impalpable). Three venous factors-venous depth, cross-sectional area, and elevation-were also measured using ultrasonography. The venous palpation score increased significantly by tapping but not by massage. Moreover, all 3 venous measurements changed significantly by tapping, while only the depth decreased significantly by massage. The three venous measurements correlated significantly with the venous palpation score, indicating that they are useful objective indicators for evaluating vasodilation. We suggest that tapping is an effective vasodilation technique.

  4. Simultaneous total occlusion of two coronary arteries associated with use of drospirenone-ethinyl estradiol (oral contraceptive).

    PubMed

    Atmaca, Hüsnü; Köprülü, Diyar; Kiriş, Tuncay; Zeren, Gönül; Şahin, İrfan

    2018-01-01

    Although the use of oral contraceptives is associated with an increased risk of venous thromboembolic disease, the risk of myocardial infarction (MI) is unclear. A new, third-generation contraceptive agent, drospirenone-ethinyl estradiol, which contains less estrogen and a new progestogen, drospirenone, in a different combination, has been considered more reliable in terms of risk of MI. However, there have been some cases of MI associated with the use of drospirenone-ethinyl estradiol, despite the protective effects of this oral contraceptive. In this report, a 33-year-old woman who had used drospirenone-ethinyl estradiol for 6 months was admitted with MI and symptoms of cardiogenic shock. Coronary angiography revealed the total occlusion of 2 coronary arteries and so percutaneous coronary intervention was performed. To the best of our knowledge, this is the first case report of simultaneous total occlusion of 2 coronary arteries associated with the use of drospirenone-ethinyl estradiol in the English-language medical literature.

  5. Competing risk of atherosclerotic risk factors for arterial and venous thrombosis in a general population: the Tromso study.

    PubMed

    Brækkan, Sigrid K; Hald, Erin M; Mathiesen, Ellisiv B; Njølstad, Inger; Wilsgaard, Tom; Rosendaal, Frits R; Hansen, John-Bjarne

    2012-02-01

    To investigate and compare the impact of traditional atherosclerotic risk factors for the risk of arterial and venous thrombosis, taking into account competing risks. In 1994-1995, 26,185 subjects were screened in the Tromsø study. Information on traditional atherosclerotic risk factors was obtained by physical examination, blood samples, and questionnaires. Subjects were followed to the first incident event of myocardial infarction (MI) or venous thromboembolism (VTE), or December 31, 2005. During a median of 10.8 years of follow-up, there were 1279 cases of incident MI and 341 VTE events. Advancing age and high body mass index were both associated with MI and VTE. Hazard ratio per decade of age was 2.34 (95% CI: 2.25-2.43) for MI and 1.87 (1.74-2.01) for VTE, and 3 kg/m(2) increase in body mass index was associated with 1.16 (1.11-1.21) and 1.20 (1.12-1.29) increased risk of MI and VTE, respectively. Blood pressure, high levels of triglycerides and total cholesterol, low HDL cholesterol, self-reported diabetes, and smoking were all associated with increased risk of MI but not associated with VTE. Our findings imply that traditional atherosclerotic risk factors, such as smoking, hypertension, dyslipidemia, and diabetes mellitus are not shared by arterial and venous thrombosis.

  6. Population-based screening for anemia using first-time blood donors

    PubMed Central

    Mast, Alan E.; Steele, Whitney R.; Johnson, Bryce; Wright, David J.; Cable, Ritchard G.; Carey, Patricia; Gottschall, Jerome L.; Kiss, Joseph E.; Simon, Toby L.; Murphy, Edward L.

    2012-01-01

    Background Anemia is an important public health concern. Data from population-based surveys such as the National Health and Nutrition Examination Survey (NHANES) are the gold standard, but are obtained infrequently and include only small samples from certain minority groups. Objectives We assessed whether readily available databases of blood donor hemoglobin values could be used as a surrogate for population hemoglobin values from NHANES. Design Blood donor venous and fingerstick hemoglobin values were compared to 10,254 NHANES 2005-2008 venous hemoglobin values using demographically stratified analyses and ANOVA. Fingerstick hemoglobins or hematocrits were converted to venous hemoglobin estimates using regression analysis. Results Venous hemoglobin values from 1,609 first time donors correlated extremely well with NHANES data across different age, gender and demographic groups. Cigarette smoking increased hemoglobin by 0.26 to 0.59 g/dL depending on intensity. Converted fingerstick hemoglobin from 36,793 first time donors agreed well with NHANES hemoglobin (weighted mean hemoglobin of 15.53 g/dL for donors and 15.73 g/dL for NHANES) with similar variation in mean hemoglobin by age. However, compared to NHANES, the larger donor dataset showed reduced differences in mean hemoglobin between Blacks and other races/ethnicities. Conclusions Overall, first-time donor fingerstick hemoglobins approximate U.S. population data and represent a readily available public health resource for ongoing anemia surveillance. PMID:22460662

  7. Risk factors associated with PICC-related upper extremity venous thrombosis in cancer patients.

    PubMed

    Yi, Xiao-lei; Chen, Jie; Li, Jia; Feng, Liang; Wang, Yan; Zhu, Jia-An; Shen, E; Hu, Bing

    2014-03-01

    To investigate the incidence and risk factors for peripherally inserted central venous catheters-related upper extremity venous thrombosis in patients with cancer. With the widespread use of peripherally inserted central venous catheters, peripherally inserted central venous catheters-related upper extremity venous thrombosis in patients with cancer leads to increasing morbidity and mortality. It is very important to further explore the incidence and risk factors for peripherally inserted central venous catheters-related venous thrombosis. Consecutive patients with cancer who were scheduled to receive peripherally inserted central venous catheters, between September 2009 and May 2012, were prospectively studied in our centre. They were investigated for venous thrombosis by Doppler sonography three times a day within 30 days after catheter insertion. Univariable and multivariable logistic regressions' analyses were performed to identify the risk factors for peripherally inserted central venous catheters-related thrombosis. A total of 89 patients with cancer were studied in our research. Of these, 81 patients were followed up within one month. The mean interval between catheter insertion and the onset of thrombosis was 12.45 ± 6.17 days. The multivariable analyses showed that chemotherapy history, less activities and diabetes were the key risk factors for thrombosis. Peripherally inserted central venous catheters-related upper extremity venous thrombosis had high incidence rate, and most cases had no significant symptoms. The history of chemotherapy, less activities and diabetes were found to be the key risk factors. It should be routinely scanned in high-risk patients every 3-5 days after catheter insertion, which would then find blood clots in time and reduce the incidence of pulmonary embolism. Risk factors associated with peripherally inserted central venous catheters-related upper extremity venous thrombosis are of critical importance in improving the quality of patients' life. It is very important to grasp the indications to reduce the incidence rate of peripherally inserted central venous catheters-related upper extremity venous thrombosis. © 2013 John Wiley & Sons Ltd.

  8. Risk factors for difficult peripheral venous cannulation in hospitalised patients. Protocol for a multicentre case-control study in 48 units of eight public hospitals in Spain.

    PubMed

    Rodriguez-Calero, Miguel Angel; Fernandez-Fernandez, Ismael; Molero-Ballester, Luis Javier; Matamalas-Massanet, Catalina; Moreno-Mejias, Luis; de Pedro-Gomez, Joan Ernest; Blanco-Mavillard, Ian; Morales-Asencio, Jose Miguel

    2018-02-08

    Patients with difficult venous access experience undesirable effects during healthcare, such as delayed diagnosis and initiation of treatment, stress and pain related to the technique and reduced satisfaction. This study aims to identify risk factors with which to model the appearance of difficulty in achieving peripheral venous puncture in hospital treatment. Case-control study. We will include adult patients requiring peripheral venous cannulation in eight public hospitals, excluding those in emergency situations and women in childbirth or during puerperium. The nurse who performs the technique will record in an anonymised register variables related to the intervention. Subsequently, a researcher will extract the health variables from the patient's medical history. Patients who present one of the following conditions will be assigned to the case group: two or more failed punctures, need for puncture support, need for central access after failure to achieve peripheral access, or decision to reject the technique. The control group will be obtained from records of patients who do not meet the above conditions. It has been stated a minimum sample size of 2070 patients, 207 cases and 1863 controls.A descriptive analysis will be made of the distribution of the phenomenon. The variables hypothesised to be risk factors for the appearance of difficult venous cannulation will be studied using a logistic regression model. The study was funded in January 2017 and obtained ethical approval from the Research Ethics Committee of the Balearic Islands. Informed consent will be obtained prior to data collection. Results will be published in a peer-reviewed scientific journal. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  9. Systemic venous drainage: can we help Newton?

    PubMed

    Corno, Antonio F

    2007-06-01

    In recent years substantial progress occurred in the techniques of cardiopulmonary bypass, but the factor potentially limiting the flexibility of cardiopulmonary bypass remains the drainage of the systemic venous return. In the daily clinical practice of cardiac surgery, the amount of systemic venous return on cardiopulmonary bypass is directly correlated with the amount of the pump flow. As a consequence, the pump flow is limited by the amount of venous return that the pump is receiving. On cardiopulmonary bypass the amount of venous drainage depends upon the central venous pressure, the height differential between patient and inlet of the venous line into the venous reservoir, and the resistance in the venous cannula(s) and circuit. The factors determining the venous return to be taken into consideration in cardiac surgery are the following: (a) characteristics of the individual patient; (b) type of planned surgical procedure; (c) type of venous cannula(s); (d) type of circuit for cardiopulmonary bypass; (e) strategy of cardiopulmonary bypass; (f) use of accessory mechanical systems to increased the systemic venous return. The careful pre-operative evaluation of all the elements affecting the systemic venous drainage, including the characteristics of the individual patient and the type of required surgical procedure, the choice of the best strategy of cardiopulmonary bypass, and the use of the most advanced materials and tools, can provide a systemic venous drainage substantially better than what it would be allowed by the simple "Law of universal gravitation" by Isaac Newton.

  10. Results of the performance verification of the CoaguChek XS system.

    PubMed

    Plesch, W; Wolf, T; Breitenbeck, N; Dikkeschei, L D; Cervero, A; Perez, P L; van den Besselaar, A M H P

    2008-01-01

    This is the first paper reporting a performance verification study of a point-of-care (POC) monitor for prothrombin time (PT) testing according to the requirements given in chapter 8 of the International Organization for Standardization (ISO) 17593:2007 standard "Clinical laboratory testing and in vitro medical devices - Requirements for in vitro monitoring systems for self-testing of oral anticoagulant therapy". The monitor under investigation was the new CoaguChek XS system which is designed for use in patient self testing. Its detection principle is based on the amperometric measurement of the thrombin activity generated by starting the coagulation cascade using a recombinant human thromboplastin. The system performance verification study was performed at four study centers using venous and capillary blood samples on two test strip lots. Laboratory testing was performed from corresponding frozen plasma samples with six commercial thromboplastins. Samples from 73 normal donors and 297 patients on oral anticoagulation therapy were collected. Results were assessed using a refined data set of 260 subjects according to the ISO 17593:2007 standard. Each of the two test strip lots met the acceptance criteria of ISO 17593:2007 versus all thromboplastins (bias -0.19 to 0.18 INR; >97% of data within accuracy limits). The coefficient of variation for imprecision of the PT determinations in INR ranged from 2.0% to 3.2% in venous, and from 2.9% to 4.0% in capillary blood testing. Capillary versus venous INR data showed agreement of results with regression lines equal to the line of identity. The new system demonstrated a high level of trueness and accuracy, and low imprecision in INR testing. It can be concluded that the CoaguChek XS system complies with the requirements in chapter 8 of the ISO standard 17593:2007.

  11. Multidetector CT of blunt traumatic venous injuries in the chest, abdomen, and pelvis.

    PubMed

    Holly, Brian P; Steenburg, Scott D

    2011-01-01

    Venous injuries as a result of blunt trauma are rare. Even though current protocols for multidetector computed tomography (CT) of patients with trauma are designed to evaluate primarily the solid organs and arteries, blunt venous injuries may nevertheless be identified, or at least suspected, on the basis of the multidetector CT findings. Venous injuries are associated with high morbidity and mortality rates. Diagnosis of a possible venous injury is crucial because the physical findings of a venous injury are nonspecific and may be absent. This article aims to make the radiologist aware of various venous injuries caused by blunt trauma and to provide helpful hints to aid in the identification of venous injuries. Multidetector CT technology, in combination with interactive manipulation of the raw dataset, can be useful in the creation of multiplanar reconstructed images and in the identification of a venous injury caused by blunt trauma. Familiarity with direct and indirect signs of venous injuries, as well as with examples of blunt traumatic venous injuries in the chest, abdomen, and pelvis, will help in the diagnosis of these injuries.

  12. The hydrostatic pressure indifference point underestimates orthostatic redistribution of blood in humans.

    PubMed

    Petersen, L G; Carlsen, J F; Nielsen, M B; Damgaard, M; Secher, N H

    2014-04-01

    The hydrostatic indifference point (HIP; where venous pressure is unaffected by posture) is located at the level of the diaphragm and is believed to indicate the orthostatic redistribution of blood, but it remains unknown whether HIP coincides with the indifference point for blood volume (VIP). During graded (± 20°) head-up (HUT) and head-down tilt (HDT) in 12 male volunteers, we determined HIP from central venous pressure and VIP from redistribution of both blood, using ultrasound imaging of the inferior caval vein (VIPui), and fluid volume, by regional electrical admittance (VIPadm). Furthermore, we evaluated whether inflation of medical antishock trousers (to 70 mmHg) affected HIP and VIP. Leaving cardiovascular variables unaffected by tilt, HIP was located 7 ± 4 cm (mean ± SD) below the 4th intercostal space (IC-4) during HUT and was similar (7 ± 3 cm) during HDT and higher (P < 0.0001) than both VIPui (HUT: 22 ± 16 cm; HDT: 13 ± 7 cm) and VIPadm (HUT: 29 ± 9 cm; HDT: 20 ± 9 cm below IC-4). During HUT antishock trousers elevated both HIP and VIPui [to 3 ± 5 cm (P = 0.028) and 17 ± 7 cm below IC-4 (P = 0.051), respectively], while VIPadm remained unaffected. By simultaneous recording of pressure and filling of the inferior caval vein as well as fluid distribution, we found HIP located corresponding to the diaphragm while VIP was placed low in the abdomen, and that medical antishock trousers elevated both HIP and VIP. The low indifference point for volume shows that the gravitational influence on distribution of blood is more profound than indicated by the indifference point for venous pressure.

  13. A reassessment of mercury in silastic strain gauge plethysmography for microvascular permeability assessment in man.

    PubMed Central

    Gamble, J; Gartside, I B; Christ, F

    1993-01-01

    1. We have used non-invasive mercury in a silastic strain gauge system to assess the effect of pressure step size, on the time course of the rapid volume response (RVR) to occlusion pressure. We also obtained values for hydraulic conductance (Kf), isovolumetric venous pressure (Pvi) and venous pressure (Pv) in thirty-five studies on the legs of twenty-three supine control subjects. 2. The initial rapid volume response to small (9.53 +/- 0.45 mmHg, mean +/- S.E.M.) stepped increases in venous pressure, the rapid volume response, could be described by a single exponential of time constant 15.54 +/- 1.14 s. 3. Increasing the size of the pressure step, to 49.8 +/- 1.1 mmHg, gave a larger value for the RVR time constant (mean 77.3 +/- 11.6 s). 4. We propose that the pressure-dependent difference in the duration of the rapid volume response, in these two situations, might be due to a vascular smooth muscle-based mechanism, e.g. the veni-arteriolar reflex. 5. The mean (+/- S.E.M.) values for Kf, Pvi and Pv were 4.27 +/- 0.18 (units, ml min-1 (100 g)-1 mmHg-1 x 10(-3), 21.50 +/- 0.81 (units, mmHg) and 9.11 +/- 0.94 (units, mmHg), respectively. 6. During simultaneous assessment of these parameters in arms and legs, it was found that they did not differ significantly from one another. 7. We propose that the mercury strain gauge system offers a useful, non-invasive means of studying the mechanisms governing fluid filtration in human limbs. Images Fig. 1 PMID:8229810

  14. Venous levels of shear support neutrophil-platelet adhesion and neutrophil aggregation in blood via P-selectin and beta2-integrin

    NASA Technical Reports Server (NTRS)

    Konstantopoulos, K.; Neelamegham, S.; Burns, A. R.; Hentzen, E.; Kansas, G. S.; Snapp, K. R.; Berg, E. L.; Hellums, J. D.; Smith, C. W.; McIntire, L. V.; hide

    1998-01-01

    BACKGROUND: After activation, platelets adhere to neutrophils via P-selectin and beta2-integrin. The molecular mechanisms and adhesion events in whole blood exposed to venous levels of hydrodynamic shear in the absence of exogenous activation remain unknown. METHODS AND RESULTS: Whole blood was sheared at approximately 100 s(-1). The kinetics of neutrophil-platelet adhesion and neutrophil aggregation were measured in real time by flow cytometry. P-selectin was upregulated to the platelet surface in response to shear and was the primary factor mediating neutrophil-platelet adhesion. The extent of neutrophil aggregation increased linearly with platelet adhesion to neutrophils. Blocking either P-selectin, its glycoprotein ligand PSGL-1, or both simultaneously by preincubation with a monoclonal antibody resulted in equivalent inhibition of neutrophil-platelet adhesion (approximately 30%) and neutrophil aggregation (approximately 70%). The residual amount of neutrophil adhesion was blocked with anti-CD11b/CD18. Treatment of blood with prostacyclin analogue ZK36374, which raises cAMP levels in platelets, blocked P-selectin upregulation and neutrophil aggregation to baseline. Complete abrogation of platelet-neutrophil adhesion required both ZK36374 and anti-CD18. Electron microscopic observations of fixed blood specimens revealed that platelets augmented neutrophil aggregation both by forming bridges between neutrophils and through contact-mediated activation. CONCLUSIONS: The results are consistent with a model in which venous levels of shear support platelet adherence to neutrophils via P-selectin binding PSGL-1. This interaction alone is sufficient to mediate neutrophil aggregation. Abrogation of platelet adhesion and aggregation requires blocking Mac-1 in addition to PSGL-1 or P-selectin. The described mechanisms are likely of key importance in the pathogenesis and progression of thrombotic disorders that are exacerbated by leukocyte-platelet aggregation.

  15. Noninvasive Imaging of Early Venous Thrombosis by 19F Magnetic Resonance Imaging With Targeted Perfluorocarbon Nanoemulsions.

    PubMed

    Temme, Sebastian; Grapentin, Christoph; Quast, Christine; Jacoby, Christoph; Grandoch, Maria; Ding, Zhaoping; Owenier, Christoph; Mayenfels, Friederike; Fischer, Jens W; Schubert, Rolf; Schrader, Jürgen; Flögel, Ulrich

    2015-04-21

    Noninvasive detection of deep venous thrombi and subsequent pulmonary thromboembolism is a serious medical challenge, since both incidences are difficult to identify by conventional ultrasound techniques. Here, we report a novel technique for the sensitive and specific identification of developing thrombi using background-free 19F magnetic resonance imaging, together with α2-antiplasmin peptide (α2AP)-targeted perfluorocarbon nanoemulsions (PFCs) as contrast agent, which is cross-linked to fibrin by active factor XIII. Ligand functionality was ensured by mild coupling conditions using the sterol-based postinsertion technique. Developing thrombi with a diameter<0.8 mm could be visualized unequivocally in the murine inferior vena cava as hot spots in vivo by simultaneous acquisition of anatomic matching 1H and 19F magnetic resonance images at 9.4 T with both excellent signal-to-noise and contrast-to-noise ratios (71±22 and 17±5, respectively). Furthermore, α2AP-PFCs could be successfully applied for the diagnosis of experimentally induced pulmonary thromboembolism. In line with the reported half-life of factor XIIIa, application of α2AP-PFCs>60 minutes after thrombus induction no longer resulted in detectable 19F magnetic resonance imaging signals. Corresponding results were obtained in ex vivo generated human clots. Thus, α2AP-PFCs can visualize freshly developed thrombi that might still be susceptible to pharmacological intervention. Our results demonstrate that 1H/19F magnetic resonance imaging, together with α2AP-PFCs, is a sensitive, noninvasive technique for the diagnosis of acute deep venous thrombi and pulmonary thromboemboli. Furthermore, ligand coupling by the sterol-based postinsertion technique represents a unique platform for the specific targeting of PFCs for in vivo 19F magnetic resonance imaging. © 2015 American Heart Association, Inc.

  16. Pulmonary venous flow index as a predictor of pulmonary vascular resistance variability in congenital heart disease with increased pulmonary flow: a comparative study before and after oxygen inhalation.

    PubMed

    Rivera, Ivan Romero; Mendonça, Maria Alayde; Andrade, José Lázaro; Moises, Valdir; Campos, Orlando; Silva, Célia Camelo; Carvalho, Antonio Carlos

    2013-09-01

    There is no definitive and reliable echocardiographic method for estimating the pulmonary vascular resistance (PVR) to differentiate persistent vascular disease from dynamic pulmonary hypertension. The aim of this study was to analyze the relationship between the pulmonary venous blood flow velocity-time integral (VTIpv) and PVR. Eighteen patients (10 females; 4 months to 22 years of age) with congenital heart disease and left to right shunt were studied. They underwent complete cardiac catheterization, including measurements of the PVR and Qp:Qs ratio, before and after 100% oxygen inhalation. Simultaneous left inferior pulmonary venous flow VTIpv was obtained by Doppler echocardiography. The PVR decreased significantly from 5.0 ± 2.6 W to 2.8 ± 2.2 W (P = 0.0001) with a significant increase in the Qp:Qs ratio, from 3.2 ± 1.4 to 4.9 ± 2.4 (P = 0.0008), and the VTIpv increased significantly from 22.6 ± 4.7 cm to 28.1 ± 6.2 cm (P = 0.0002) after 100% oxygen inhalation. VTIpv correlated well with the PVR and Qp:Qs ratio (r = -0.74 and 0.72, respectively). Diagnostic indexes indicated a sensitivity of 86%, specificity of 75%, accuracy of 83%, a positive predictive value of 92% and a negative predictive value of 60%. The VTIpv correlated well with the PVR. The measurement of this index before and after oxygen inhalation may become a useful noninvasive test for differentiating persistent vascular disease from dynamic and flow-related pulmonary hypertension. © 2013, Wiley Periodicals, Inc.

  17. Venous levels of shear support neutrophil-platelet adhesion and neutrophil aggregation in blood via P-selectin and beta2-integrin.

    PubMed

    Konstantopoulos, K; Neelamegham, S; Burns, A R; Hentzen, E; Kansas, G S; Snapp, K R; Berg, E L; Hellums, J D; Smith, C W; McIntire, L V; Simon, S I

    1998-09-01

    After activation, platelets adhere to neutrophils via P-selectin and beta2-integrin. The molecular mechanisms and adhesion events in whole blood exposed to venous levels of hydrodynamic shear in the absence of exogenous activation remain unknown. Whole blood was sheared at approximately 100 s(-1). The kinetics of neutrophil-platelet adhesion and neutrophil aggregation were measured in real time by flow cytometry. P-selectin was upregulated to the platelet surface in response to shear and was the primary factor mediating neutrophil-platelet adhesion. The extent of neutrophil aggregation increased linearly with platelet adhesion to neutrophils. Blocking either P-selectin, its glycoprotein ligand PSGL-1, or both simultaneously by preincubation with a monoclonal antibody resulted in equivalent inhibition of neutrophil-platelet adhesion (approximately 30%) and neutrophil aggregation (approximately 70%). The residual amount of neutrophil adhesion was blocked with anti-CD11b/CD18. Treatment of blood with prostacyclin analogue ZK36374, which raises cAMP levels in platelets, blocked P-selectin upregulation and neutrophil aggregation to baseline. Complete abrogation of platelet-neutrophil adhesion required both ZK36374 and anti-CD18. Electron microscopic observations of fixed blood specimens revealed that platelets augmented neutrophil aggregation both by forming bridges between neutrophils and through contact-mediated activation. The results are consistent with a model in which venous levels of shear support platelet adherence to neutrophils via P-selectin binding PSGL-1. This interaction alone is sufficient to mediate neutrophil aggregation. Abrogation of platelet adhesion and aggregation requires blocking Mac-1 in addition to PSGL-1 or P-selectin. The described mechanisms are likely of key importance in the pathogenesis and progression of thrombotic disorders that are exacerbated by leukocyte-platelet aggregation.

  18. Different regions of latest electrical activation during left bundle-branch block and right ventricular pacing in cardiac resynchronization therapy patients determined by coronary venous electro-anatomic mapping.

    PubMed

    Mafi Rad, Masih; Blaauw, Yuri; Dinh, Trang; Pison, Laurent; Crijns, Harry J; Prinzen, Frits W; Vernooy, Kevin

    2014-11-01

    Current targeted left ventricular (LV) lead placement strategy is directed at the latest activated region during intrinsic activation. However, cardiac resynchronization therapy (CRT) is most commonly applied by simultaneous LV and right ventricular (RV) pacing without contribution from intrinsic conduction. Therefore, targeting the LV lead to the latest activated region during RV pacing might be more appropriate. We investigated the difference in LV electrical activation sequence between left bundle-branch block (LBBB) and RV apex (RVA) pacing using coronary venous electro-anatomic mapping (EAM). Twenty consecutive CRT candidates with LBBB underwent intra-procedural coronary venous EAM during intrinsic activation and RVA pacing using EnSite NavX. Left ventricular lead placement was aimed at the latest activated region during LBBB according to current recommendations. In all patients, LBBB was associated with a circumferential LV activation pattern, whereas RVA pacing resulted in activation from the apex of the heart to the base. In 10 of 20 patients, RVA pacing shifted the latest activated region relative to LBBB. In 18 of 20 patients, the LV lead was successfully positioned in the latest activated region during LBBB. For the whole study population, LV lead electrical delay, expressed as percentage of QRS duration, was significantly shorter during RVA pacing than during LBBB (72 ± 13 vs. 82 ± 5%, P = 0.035). Right ventricular apex pacing alters LV electrical activation pattern in CRT patients with LBBB, and shifts the latest activated region in a significant proportion of these patients. These findings warrant reconsideration of the current practice of LV lead targeting for CRT. © 2014 The Authors. European Journal of Heart Failure © 2014 European Society of Cardiology.

  19. Upper Body Venous Compliance Exceeds Lower Body Venous Compliance in Humans

    NASA Technical Reports Server (NTRS)

    Watenpaugh, Donald E.

    1996-01-01

    Human venous compliance hypothetically decreases from upper to lower body as a mechanism for maintenance of the hydrostatic indifference level 'headward' in the body, near the heart. This maintains cardiac filling pressure, and thus cardiac output and cerebral perfusion, during orthostasis. This project entailed four steps. First, acute whole-body tilting was employed to alter human calf and neck venous volumes. Subjects were tilted on a tilt table equipped with a footplate as follows: 90 deg, 53 deg, 30 deg, 12 deg, O deg, -6 deg, -12 deg, -6 deg, O deg, 12 deg, 30 deg, 53 deg, and 90 deg. Tilt angles were held for 30 sec each, with 10 sec transitions between angles. Neck volume increased and calf volume decreased during head-down tilting, and the opposite occurred during head-up tilt. Second, I sought to cross-validate Katkov and Chestukhin's (1980) measurements of human leg and neck venous pressures during whole-body tilting, so that those data could be used with volume data from the present study to calculate calf and neck venous compliance (compliance = (Delta)volume/(Delta)pressure). Direct measurements of venous pressures during postural chances and whole-body tilting confirmed that the local changes in venous pressures seen by Katkov and Chestukhin (1980) are valid. The present data also confirmed that gravitational changes in calf venous pressure substantially exceed those changes in upper body venous pressure. Third, the volume and pressure data above were used to find that human neck venous compliance exceeds calf venous compliance by a factor of 6, thereby upholding the primary hypothesis. Also, calf and neck venous compliance correlated significantly with each other (r(exp 2) = 0.56). Fourth, I wished to determine whether human calf muscle activation during head-up tilt reduces calf venous compliance. Findings from tilting and from supine assessments of relaxed calf venous compliance were similar, indicating that tilt-induced muscle activation is relatively unimportant. Low calf venous compliance probably results from stiffer venous, skeletal muscle, and connective tissues, and better-developed local and central neural controls of venous distensibility. This research establishes that upper-to-lower body reduction of venous compliance can explain headward positioning of the hydrostatic indifference level in humans.

  20. Modification of hemi-Fontan operation for patients with functional single ventricle and anomalous pulmonary venous connection to the superior vena cava: mid-term results†

    PubMed Central

    Ito, Hiroki; Murata, Masaya; Ide, Yujiro; Sugano, Mikio; Kanno, Kazuyoshi; Imai, Kenta; Ishido, Motonori; Fukuba, Ryohei; Sakamoto, Kisaburo

    2016-01-01

    OBJECTIVES Fontan candidates with mixed totally anomalous pulmonary venous connection often have postoperative pulmonary venous obstruction after cavopulmonary anastomosis. Because some pulmonary venous obstructions have no intimal hypertrophy at reoperation, we considered such pulmonary venous obstructions to be caused by 3D deformities arising from dissection or mobilization of the vessels, and hypothesized that keeping the pulmonary venous branches in a natural position could avoid such obstruction. Here, we evaluated a modified hemi-Fontan strategy consisting of minimal dissection with no division of vessels and patch separation between systemic and pulmonary venous flow. METHODS We retrospectively reviewed clinical records of infants with a functional single ventricle and supracardiac anomalous pulmonary venous connection who had undergone this procedure between 2002 and 2012. RESULTS Nine infants underwent this procedure (median age, 5.6 months; range 3.2–30), all with right atrial isomerism and several pulmonary venous branches directly and separately connecting to the superior vena cava. In 5 patients, all pulmonary veins drained into the superior vena cava; in 1, the right pulmonary veins drained into the superior vena cava and in 3, a pulmonary venous branch drained into the superior vena cava. The median follow-up was 6.9 years (0.8–13 years). Three patients underwent reoperation for postoperative pulmonary venous obstruction caused by intimal hypertrophy; however, we confirmed no pulmonary venous obstruction caused by 3D deformities on the pulmonary venous branches connecting separately to the superior vena cava. Although 2 patients were effectively relieved from pulmonary venous obstruction, 1 died due to recurrent pulmonary venous obstruction. There was no late death and no sinus-node dysfunction. Eight patients underwent successful Fontan operation and catheterization. The median interval from the Fontan operation to the latest catheterization was 3.7 years (0.9–3.7 years). The median arterial oxygen saturation was 94% (91–97%) and the central venous pressure was 12 mmHg (8–14 mmHg); no deficiency of pulmonary arteries and veins was noted. CONCLUSIONS For patients with functional single ventricle and anomalous pulmonary venous connections to the superior vena cava, our novel strategy of second-stage palliation could avoid postoperative pulmonary venous obstruction caused by 3D deformities, but may not eliminate pulmonary venous obstruction caused by intimal hypertrophy. PMID:26860898

  1. Increased brain serotonin turnover in panic disorder patients in the absence of a panic attack: reduction by a selective serotonin reuptake inhibitor.

    PubMed

    Esler, Murray; Lambert, Elisabeth; Alvarenga, Marlies; Socratous, Florentia; Richards, Jeff; Barton, David; Pier, Ciaran; Brenchley, Celia; Dawood, Tye; Hastings, Jacqueline; Guo, Ling; Haikerwal, Deepak; Kaye, David; Jennings, Garry; Kalff, Victor; Kelly, Michael; Wiesner, Glen; Lambert, Gavin

    2007-08-01

    Since the brain neurotransmitter changes characterising panic disorder remain uncertain, we quantified brain noradrenaline and serotonin turnover in patients with panic disorder, in the absence of a panic attack. Thirty-four untreated patients with panic disorder and 24 matched healthy volunteers were studied. A novel method utilising internal jugular venous sampling, with thermodilution measurement of jugular blood flow, was used to directly quantify brain monoamine turnover, by measuring the overflow of noradrenaline and serotonin metabolites from the brain. Radiographic depiction of brain venous sinuses allowed differential venous sampling from cortical and subcortical regions. The relation of brain serotonin turnover to serotonin transporter genotype and panic disorder severity were evaluated, and the influence of an SSRI drug, citalopram, on serotonin turnover investigated. Brain noradrenaline turnover in panic disorder patients was similar to that in healthy subjects. In contrast, brain serotonin turnover, estimated from jugular venous overflow of the metabolite, 5-hydroxyindole acetic acid, was increased approximately 4-fold in subcortical brain regions and in the cerebral cortex (P < 0.01). Serotonin turnover was highest in patients with the most severe disease, was unrelated to serotonin transporter genotype, and was reduced by citalopram (P < 0.01). Normal brain noradrenaline turnover in panic disorder patients argues against primary importance of the locus coeruleus in this condition. The marked increase in serotonin turnover, in the absence of a panic attack, possibly represents an important underlying neurotransmitter substrate for the disorder, although this point remains uncertain. Support for this interpretation comes from the direct relationship which existed between serotonin turnover and illness severity, and the finding that SSRI administration reduced serotonin turnover. Serotonin transporter genotyping suggested that increased whole brain serotonin turnover most likely derived not from impaired serotonin reuptake, but from increased firing in serotonergic midbrain raphe neurons projecting to both subcortical brain regions and the cerebral cortex.

  2. Use of artificial intelligence to identify cardiovascular compromise in a model of hemorrhagic shock.

    PubMed

    Glass, Todd F; Knapp, Jason; Amburn, Philip; Clay, Bruce A; Kabrisky, Matt; Rogers, Steven K; Garcia, Victor F

    2004-02-01

    To determine whether a prototype artificial intelligence system can identify volume of hemorrhage in a porcine model of controlled hemorrhagic shock. Prospective in vivo animal model of hemorrhagic shock. Research foundation animal surgical suite; computer laboratories of collaborating industry partner. Nineteen, juvenile, 25- to 35-kg, male and female swine. Anesthetized animals were instrumented for arterial and systemic venous pressure monitoring and blood sampling, and a splenectomy was performed. Following a 1-hr stabilization period, animals were hemorrhaged in aliquots to 10, 20, 30, 35, 40, 45, and 50% of total blood volume with a 10-min recovery between each aliquot. Data were downloaded directly from a commercial monitoring system into a proprietary PC-based software package for analysis. Arterial and venous blood gas values, glucose, and cardiac output were collected at specified intervals. Electrocardiogram, electroencephalogram, mixed venous oxygen saturation, temperature (core and blood), mean arterial pressure, pulmonary artery pressure, central venous pressure, pulse oximetry, and end-tidal CO(2) were continuously monitored and downloaded. Seventeen of 19 animals (89%) died as a direct result of hemorrhage. Stored data streams were analyzed by the prototype artificial intelligence system. For this project, the artificial intelligence system identified and compared three electrocardiographic features (R-R interval, QRS amplitude, and R-S interval) from each of nine unknown samples of the QRS complex. We found that the artificial intelligence system, trained on only three electrocardiographic features, identified hemorrhage volume with an average accuracy of 91% (95% confidence interval, 84-96%). These experiments demonstrate that an artificial intelligence system, based solely on the analysis of QRS amplitude, R-R interval, and R-S interval of an electrocardiogram, is able to accurately identify hemorrhage volume in a porcine model of lethal hemorrhagic shock. We suggest that this technology may represent a noninvasive means of assessing the physiologic state during and immediately following hemorrhage. Point of care application of this technology may improve outcomes with earlier diagnosis and better titration of therapy of shock.

  3. Effects of acute hypoxia on cardiopulmonary responses to head-down tilt

    NASA Technical Reports Server (NTRS)

    Loeppky, J. A.; Luft, U. C.; Scotto, P.; Chick, T. W.

    1990-01-01

    Six male subjects were exposed on two separate occasions to simulated microgravity with 28 deg head-down tilt (HD) for 1 h with baseline followed by recovery at + 17 deg head-up. Pulmonary ventilation, gas exchange, spirometry, and central and cerebral blood flow characteristics were compared while breathing ambient air and reduced F(I)O2 equivalent to 14,828 ft. With hypoxia (HY), the increased tidal volume served to attenuate the drop in arterial saturation by reducing deadspace ventilation. Arterial and mixed venous PO2, values, estimated from peripheral venous samples and cardiac output (CO), were both maintained during HD in HY. Mixed venous PO2 was elevated by an increase in CO associated with a reduction in systemic resistance. Changes in spirometric indices during HD were not accentuated by HY, making the presence of interstitial edema unlikely. Cerebral flow and resistance showed minor reductions with HD. Tissue oxygenation and cardiopulmonary function were not notably effected by HD during HY, but a combination of these two stressors may predispose subjects to subsequent orthostatic intolerance during initial recovery.

  4. Early pregnancy cerebral venous thrombosis and status epilepticus treated with levetiracetam and lacosamide throughout pregnancy.

    PubMed

    Ylikotila, Pauli; Ketola, Raimo A; Timonen, Susanna; Malm, Heli; Ruuskanen, Jori O

    2015-11-01

    Cerebral venous thrombosis (CVT) is an uncommon cause of stroke, accounting to less than 1% of all strokes. We describe a pregnant woman with a massive CVT in early pregnancy, complicated by status epilepticus. The mother was treated with levetiracetam, lacosamide, and enoxaparin throughout pregnancy. A male infant was born on pregnancy week 36, weighing 2.2kg. Both levetiracetam and and lacosamide were present in cord blood in levels similar to those in maternal blood. The infant was partially breast-fed and experienced poor feeding and sleepiness, starting to resolve after two first weeks. Milk samples were drawn 5 days after the delivery and a blood sample from the infant 3 days later. Lacosamide level in milk was low, resulting in an estimated relative infant dose of 1.8% of the maternal weight-adjusted daily dose in a fully breast-fed infant. This is the first case describing lacosamide use during pregnancy and lactation. Copyright © 2015 Elsevier Inc. All rights reserved.

  5. Evaluation of rivaroxaban use in patients with gynecologic malignancies at an academic medical center: A pilot study.

    PubMed

    Signorelli, Jessie R; Gandhi, Arpita S

    2017-01-01

    Background Patients with gynecologic malignancies are at an increased risk for venous thromboembolism. National guidelines recommend treatment of an acute venous thromboembolism with low molecular weight heparin for 5-10 days followed by long-term secondary prophylaxis with low molecular weight heparin for at least six months. Non-vitamin K oral anticoagulants are not currently recommended to be used in cancer patients for the management of venous thromboembolism because robust data on their efficacy and safety have yet to become available in cancer patients. The objectives of this study were to determine the proportion of gynecologic oncology patients with venous thromboembolism using rivaroxaban compared to warfarin or low molecular weight heparin as well as compare the safety and efficacy of these anticoagulants. Methods This study was a retrospective pilot analysis of adult patients with gynecologic malignancies who received either rivaroxaban, warfarin or low molecular weight heparin for treatment of venous thromboembolism at Augusta University Medical Center from 1 July 2013 to 30 June 2015. Statistical comparisons between the enoxaparin and rivaroxaban group were made using T-tests and Chi-square or Fisher's exact tests, where appropriate. Results Out of the 49 patients, 37% (18) patients were on rivaroxaban, 53% (26) on enoxaparin, and 10% (5) on warfarin. Only one patient (4%) in the enoxaparin group experienced a recurrent deep vein thrombosis while there were no cases of recurrent venous thromboembolism in the rivaroxaban and warfarin group. The incidence of major bleeding was 17% ( n = 2), 20% ( n = 1), and 8% ( n = 2) in patients receiving rivaroxaban, enoxaparin, and warfarin, respectively. The rate of switching to a different anticoagulant than originally prescribed was 42% ( n = 14) in the enoxaparin arm, and 5.5% ( n = 1) in the rivaroxaban arm. Conclusion A high proportion of our gynecologic oncology patients received rivaroxaban for the management of venous thromboembolism. The sample size of this pilot analysis was too small to draw any conclusions regarding efficacy and safety of rivaroxaban compared with enoxaparin and warfarin. High rate of rivaroxaban use in gynecologic oncology patients at our institution highlights the need for larger, well-designed randomized controlled trials to confirm the safety and efficacy of its use in this population.

  6. Peripheral Venous Access Ports: Outcomes Analysis in 109 Patients

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bodner, Leonard J.; Nosher, John L.; Patel, Kaushik M.

    Purpose: To perform a retrospective outcomes analysis of central venous catheters with peripheral venous access ports, with comparison to published data.Methods: One hundred and twelve central venous catheters with peripherally placed access ports were placed under sonographic guidance in 109 patients over a 4-year period. Ports were placed for the administration of chemotherapy, hyperalimentation, long-term antibiotic therapy, gamma-globulin therapy, and frequent blood sampling. A vein in the upper arm was accessed in each case and the catheter was passed to the superior vena cava or right atrium. Povidone iodine skin preparation was used in the first 65 port insertions. Amore » combination of Iodophor solution and povidone iodine solution was used in the last 47 port insertions. Forty patients received low-dose (1 mg) warfarin sodium beginning the day after port insertion. Three patients received higher doses of warfarin sodium for preexistent venous thrombosis. Catheter performance and complications were assessed and compared with published data.Results: Access into the basilic or brachial veins was obtained in all cases. Ports remained functional for a total of 28,936 patient days. The port functioned in 50% of patients until completion of therapy, or the patient's expiration. Ports were removed prior to completion of therapy in 18% of patients. Eleven patients (9.9% of ports placed) suffered an infectious complication (0.38 per thousand catheter-days)-in nine, at the port implantation site, in two along the catheter. In all 11 instances the port was removed. Port pocket infection in the early postoperative period occurred in three patients (4.7%) receiving a Betadine prep vs two patients (4.2%) receiving a standard O.R. prep. This difference was not statistically significant (p = 0.9). Venous thrombosis occurred in three patients (6.8%) receiving warfarin sodium and in two patients (3%) not receiving warfarin sodium. This difference was not statistically significant (p = 0.6). Aspiration occlusion occurred in 13 patients (11.7%). Intracatheter urokinase was infused in eight of these patients and successfully restored catheter function in all but two instances. These complication rates are comparable to or better than those reported with chest ports.Conclusion: Peripheral ports for long-term central venous access placed by interventional radiologists in the interventional radiology suite are as safe and as effective as chest ports.« less

  7. 21 CFR 870.1140 - Venous blood pressure manometer.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Venous blood pressure manometer. 870.1140 Section... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1140 Venous blood pressure manometer. (a) Identification. A venous blood pressure manometer is a device attached to a venous...

  8. 21 CFR 870.1140 - Venous blood pressure manometer.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Venous blood pressure manometer. 870.1140 Section... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1140 Venous blood pressure manometer. (a) Identification. A venous blood pressure manometer is a device attached to a venous...

  9. 21 CFR 870.1140 - Venous blood pressure manometer.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Venous blood pressure manometer. 870.1140 Section... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1140 Venous blood pressure manometer. (a) Identification. A venous blood pressure manometer is a device attached to a venous...

  10. 21 CFR 870.1140 - Venous blood pressure manometer.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Venous blood pressure manometer. 870.1140 Section... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1140 Venous blood pressure manometer. (a) Identification. A venous blood pressure manometer is a device attached to a venous...

  11. Current Status of the Application of Intracranial Venous Sinus Stenting

    PubMed Central

    Xu, Kan; Yu, Tiecheng; Yuan, Yongjie; Yu, Jinlu

    2015-01-01

    The intracranial venous sinus is an important component of vascular disease. Many diseases involve the venous sinus and are accompanied by venous sinus stenosis (VSS), which leads to increased venous pressure and high intracranial pressure. Recent research has focused on stenting as a treatment for VSS related to these diseases. However, a systematic understanding of venous sinus stenting (VS-Stenting) is lacking. Herein, the literature on idiopathic intracranial hypertension (IIH), venous pulsatile tinnitus, sinus thrombosis, high draining venous pressure in dural arteriovenous fistula (AVF) and arteriovenous malformation (AVM), and tumor-caused VSS was reviewed and analyzed to summarize experiences with VS-Stenting as a treatment. The literature review showed that satisfactory therapeutic effects can be achieved through stent angioplasty. Thus, the present study suggests that selective stent release in the venous sinus can effectively treat these diseases and provide new possibilities for treating intracranial vascular disease. PMID:26516306

  12. One versus two venous anastomoses in microsurgical head and neck reconstruction: a cumulative meta-analysis.

    PubMed

    Christianto, S; Lau, A; Li, K Y; Yang, W F; Su, Y X

    2018-05-01

    Venous compromise is still the most common cause of free flap failure. The use of two venous anastomoses has been advocated to reduce venous compromise. However, the effectiveness of this approach remains controversial. A systematic review and cumulative meta-analysis was performed to assess the effect of one versus two venous anastomoses on venous compromise and free flap failure in head and neck microsurgical reconstruction. A total of 27 articles reporting 7389 flaps were included in this study. On comparison of one versus two venous anastomoses, the odds ratio (OR) for flap failure was 1.66 (95% confidence interval 1.11-2.50; P=0.014) and for venous compromise was 1.50 (95% confidence interval 1.10-2.05; P=0.011), suggesting a significant increase in the flap failure rate and venous compromise rate in the single venous anastomosis group. These results show that the execution of two venous anastomoses has significant effects on reducing the vascular compromise and free flap failure rate in head and neck reconstruction. Copyright © 2018 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  13. Is there a link between the structural impact of thoracic outlet and the development of central venous stenosis?

    PubMed

    Kotoda, Atsushi; Akimoto, Tetsu; Sugase, Taro; Yamamoto, Hisashi; Kusano, Eiji

    2013-01-01

    Central venous stenosis (CVS) is a serious complication for chronic hemodialysis (HD) patients. Previous reports of CVS have focused on prior central venous catheterization, because of the higher prevalence and potential for prevention of such an event. However, recent studies have demonstrated that CVS may also develop without a history of central venous catheterization. Although information about the etiological backgrounds regarding the development of CVS without previous central venous catheterization have gradually accumulated, the clinical impact of the chronic compression of the central venous system by the surrounding structures, which may likely determine the central venous susceptibility to CVS, remains poorly understood. This study proposes the hypothesis that the combination of chronic venous compression at the level of thoracic outlet characterized by the natural physique and elevated venous flow induced by the creation of vascular access should be evaluated as a potential factor for the development of CVS, since they may accelerate the development of venous stenosis, presumably through the stimulation of intimal hyperplasia, and thereby the subclavian venous susceptibility to CVS should be determined. Copyright © 2012 Elsevier Ltd. All rights reserved.

  14. Noninvasive assessment of left atrial maximum dP/dt by a combination of transmitral and pulmonary venous flow.

    PubMed

    Nakatani, S; Garcia, M J; Firstenberg, M S; Rodriguez, L; Grimm, R A; Greenberg, N L; McCarthy, P M; Vandervoort, P M; Thomas, J D

    1999-09-01

    The study assessed whether hemodynamic parameters of left atrial (LA) systolic function could be estimated noninvasively using Doppler echocardiography. Left atrial systolic function is an important aspect of cardiac function. Doppler echocardiography can measure changes in LA volume, but has not been shown to relate to hemodynamic parameters such as the maximal value of the first derivative of the pressure (LA dP/dt(max)). Eighteen patients in sinus rhythm were studied immediately before and after open heart surgery using simultaneous LA pressure measurements and intraoperative transesophageal echocardiography. Left atrial pressure was measured with a micromanometer catheter, and LA dP/dt(max) during atrial contraction was obtained. Transmitral and pulmonary venous flow were recorded by pulsed Doppler echocardiography. Peak velocity, and mean acceleration and deceleration, and the time-velocity integral of each flow during atrial contraction was measured. The initial eight patients served as the study group to derive a multilinear regression equation to estimate LA dP/dt(max) from Doppler parameters, and the latter 10 patients served as the test group to validate the equation. A previously validated numeric model was used to confirm these results. In the study group, LA dP/dt(max) showed a linear relation with LA pressure before atrial contraction (r = 0.80, p < 0.005), confirming the presence of the Frank-Starling mechanism in the LA. Among transmitral flow parameters, mean acceleration showed the strongest correlation with LA dP/dt(max) (r = 0.78, p < 0.001). Among pulmonary venous flow parameters, no single parameter was sufficient to estimate LA dP/dt(max) with an r2 > 0.30. By stepwise and multiple linear regression analysis, LA dP/dt(max) was best described as follows: LA dP/dt(max) = 0.1 M-AC +/- 1.8 P-V - 4.1; r = 0.88, p < 0.0001, where M-AC is the mean acceleration of transmitral flow and P-V is the peak velocity of pulmonary venous flow during atrial contraction. This equation was tested in the latter 10 patients of the test group. Predicted and measured LA dP/dt(max) correlated well (r = 0.90, p < 0.0001). Numerical simulation verified that this relationship held across a wide range of atrial elastance, ventricular relaxation and systolic function, with LA dP/dt(max) predicted by the above equation with r = 0.94. A combination of transmitral and pulmonary venous flow parameters can provide a hemodynamic assessment of LA systolic function.

  15. [Experimental study of acute brain swelling under acute intracranial hypertension (author's transl)].

    PubMed

    Shigemori, M; Watanabe, M; Kuramoto, S

    1976-12-01

    There are many problems about the cause, pathophysiology and treatment of acute brain swelling under intracranial hypertension frequently encountered in the neurosurgical clinics. Generally, rapid increase of the cerebral vasoparesis caused by unknown etiology is thought to be the main cause of acute brain swelling under intracranial hypertension. Moreover, disturbance of the cerebral venous circulatory system is discussed recently by many authors. But, research from the point of systemic respiration and hemodynamics is necessary for resolving these problems. This experiment was designed to study the effects of respiration and hemodynamics on the cerebral vasoparesis. Using 22 adult dogs, acute intracranial hypertension was produced by epidural balloon inflation sustained at the level of 300 - 400 mmH2O. Simultaneously with measurement of intracranial pressure at the epidural space, superior sagittal sinus pressure, respirogram, systemic blood pressure (femoral artery), central venous pressure, common carotid blood flow, EKG and bipolar lead EEG were monitored continuously. The experimental group was divided by the respiratory loading into 5 groups as follows: control (6 cases), 10% CO2 hypercapnia (4 cases), 10% O2 hypoxia (4 cases), stenosis of airway (5 cases), 100% O2-controled respiration (3 cases). 1) Cerebral vasoparesis under acute intracranial hypertension took place earlier and showed more rapid progression in groups of stenosis of airway, hypercapnia and hypoxia than control group of spontaneous respiration in room air. No occurrence of cerebral vasoparesis was found out in a group of 100% O2 controlled respiration. It is proved that increased airway resistance or asphyxia, hypercapnia and hypoxia have strictly reference to the occurrence and progression of cerebral vasoparesis and for the prevention of cerebral vasoparesis, correct 100% O2 cont rolled respiration is effective. 2) From the hemodynamic change, the progression of rapid increase of cerebral blood volume with increase of blood volume in the superior sagitta sinus during cerebral vasoparesis under intracranial hypertension is presumed. It is suggested from the superior sagittal sinus pressure in various experimental groups that the site, reactivity and disturbed degree of the cerebral venous system are changed by the difference of respiratory or ventrilatory state and the cerebral venous circulatory disturbance has also reference to the occurrence of acute brain swelling. 3) During cerebral vasopareris under acute intracranial hypertension, remarkable supression of respiration, increased central venous pressure and increased common carotid blood flow were observed. It is concluded that the reaction of systemic hemodynamics following respiratory change effects on cerebral circulation markedly and they are being important factors to occurrence of acute brain swelling.

  16. Noninvasive assessment of left atrial maximum dP/dt by a combination of transmitral and pulmonary venous flow

    NASA Technical Reports Server (NTRS)

    Nakatani, S.; Garcia, M. J.; Firstenberg, M. S.; Rodriguez, L.; Grimm, R. A.; Greenberg, N. L.; McCarthy, P. M.; Vandervoort, P. M.; Thomas, J. D.

    1999-01-01

    OBJECTIVES: The study assessed whether hemodynamic parameters of left atrial (LA) systolic function could be estimated noninvasively using Doppler echocardiography. BACKGROUND: Left atrial systolic function is an important aspect of cardiac function. Doppler echocardiography can measure changes in LA volume, but has not been shown to relate to hemodynamic parameters such as the maximal value of the first derivative of the pressure (LA dP/dt(max)). METHODS: Eighteen patients in sinus rhythm were studied immediately before and after open heart surgery using simultaneous LA pressure measurements and intraoperative transesophageal echocardiography. Left atrial pressure was measured with a micromanometer catheter, and LA dP/dt(max) during atrial contraction was obtained. Transmitral and pulmonary venous flow were recorded by pulsed Doppler echocardiography. Peak velocity, and mean acceleration and deceleration, and the time-velocity integral of each flow during atrial contraction was measured. The initial eight patients served as the study group to derive a multilinear regression equation to estimate LA dP/dt(max) from Doppler parameters, and the latter 10 patients served as the test group to validate the equation. A previously validated numeric model was used to confirm these results. RESULTS: In the study group, LA dP/dt(max) showed a linear relation with LA pressure before atrial contraction (r = 0.80, p < 0.005), confirming the presence of the Frank-Starling mechanism in the LA. Among transmitral flow parameters, mean acceleration showed the strongest correlation with LA dP/dt(max) (r = 0.78, p < 0.001). Among pulmonary venous flow parameters, no single parameter was sufficient to estimate LA dP/dt(max) with an r2 > 0.30. By stepwise and multiple linear regression analysis, LA dP/dt(max) was best described as follows: LA dP/dt(max) = 0.1 M-AC +/- 1.8 P-V - 4.1; r = 0.88, p < 0.0001, where M-AC is the mean acceleration of transmitral flow and P-V is the peak velocity of pulmonary venous flow during atrial contraction. This equation was tested in the latter 10 patients of the test group. Predicted and measured LA dP/dt(max) correlated well (r = 0.90, p < 0.0001). Numerical simulation verified that this relationship held across a wide range of atrial elastance, ventricular relaxation and systolic function, with LA dP/dt(max) predicted by the above equation with r = 0.94. CONCLUSIONS: A combination of transmitral and pulmonary venous flow parameters can provide a hemodynamic assessment of LA systolic function.

  17. CONTROLLED METHYL TERTIARY BUTYL ETHER (MTBE) EXPOSURE TO HUMANS THROUGH DERMAL, INGESTION, AND INHALATION ROUTES AND THE RESULTANT BIOMARKER TERTIARY BUTYL ALCOHOL (TBA) AS MEASURED IN EXHALED BREATH AND VENOUS BLOOD

    EPA Science Inventory

    Radiocarbon (14C) measurements provide an estimate of the fraction of carbon in a sample that is biogenic. In September 1997 during SCOS97 a series of 3-h canister samples of ambient air were collected at the Azusa air monitoring station during morning and afternoon periods. ...

  18. Does the method of expression of venous blood affect ischaemia/reperfusion damage in tourniquet use? An experimental study on rabbits.

    PubMed

    Iltar, Serkan; Kılınç, Cem Yalın; Alemdaroğlu, Kadir Bahadır; Ozcan, Selahattin; Aydoğan, Nevres Hürriyet; Sürer, Hatice; Kılınç, Aytün Şadan

    2013-11-01

    The aim of this study was to compare the ischaemia and reperfusion phases of two tourniquet application models (Group 1: expressing the blood by a sterile rubber bandage and Group 2: elevation of the limb for several minutes) using an analysis of ischaemia/reperfusion parameters and blood pH. Sixteen New Zealand rabbits were used. Muscle samples were extracted from the triceps surae; at phase A (baseline: just before tourniquet application), phase B (ischaemia: 3h after tourniquet inflation) and phase C (2h after tourniquet deflation). Nitrite, nitrate, reduced glutathione, myeloperoxidase, malondyaldehyde were measured in the samples. Blood pH was also measured at each phase. Group 2 had significantly decreased nitrite (p=0.007) and nitrate (p=0.01) levels compared to Group 1 while passing from phase A to phase B. The pH decrease through the phases was significant within Group 1 (p=0.006) and was not significant within Group 2 (p=0.052). Lower levels of NO metabolites nitrate and nitrite, result from tourniquet use with incomplete venous blood expression by elevation. Also, with this technique severe acidosis is less likely to occur than when a tourniquet is used with expression of the venous blood by rubber bandage. These findings may help in the decision of which tourniquet technique is to be used for potentially long operations which may exceed 2h. Copyright © 2013 Elsevier Ltd. All rights reserved.

  19. Stasis dermatitis and ulcers

    MedlinePlus

    ... ulcers; Ulcers - venous; Venous ulcer; Venous insufficiency - stasis dermatitis; Vein - stasis dermatitis ... veins. Some people with venous insufficiency develop stasis dermatitis. Blood pools in the veins of the lower ...

  20. A New Technique for Femoral Venous Access in Infants Using Arterial Injection Venous Return Guidance

    PubMed Central

    Ebishima, Hironori; Kitano, Masataka; Kurosaki, Kenichi; Shiraishi, Isao

    2017-01-01

    Objectives: Although venography guidance is helpful for central venous catheter placement, it is sometimes difficult to place a peripheral intravenous cannula for enhancement. We designed a new technique for establishing femoral venous access using venography guidance in the return phase of peripheral arteriography. This new technique was named arterial injection venous return guidance. Here we assessed the efficacy and safety of arterial injection venous return guidance. Methods: We reviewed data of 29 infants less than 6 months old undergoing catheter intervention at our institute in 2014. Of the 29 patients, femoral venous cannulation was performed using arterial injection venous return guidance in 5 patients, venography in 20 patients, and the landmark method in 4 patients. The technical success rates and incidence of complications were compared. Results: The overall success rates were 100% in the arterial injection venous return-guided and venography-guided groups. The mean procedure duration and mean contrast material injection time were similar between the groups. The contrast effect on the femoral vein in the arterial injection venous return-guided group was lower than that in the venography-guided group, but adequate for surgery. The overall complication rate was 17%, and obstruction of previously placed intravenous catheters was the most common complication. Conclusions: Therefore, the arterial injection venous return guidance technique was as safe and efficient as venography for establishing venous access. PMID:29034015

  1. A failure of preoperative duplex imaging to diagnose a lower extremity venous aneurysm in a patient with severe chronic venous insufficiency.

    PubMed

    Jones, Roy Wesley; Parkerson, Godfrey Ross; Ottinger, Mary; Rodriguez, Eduardo; Park, Brian

    2017-01-01

    We present a case of recurrent bilateral lower extremity venous stasis ulcers in association with a superficial venous aneurysm at the right saphenofemoral junction that was misdiagnosed on preoperative duplex scanning. A 53-year-old female presented to our clinic with 6-year history of bilateral lower extremity venous stasis ulcers. Her past medical history was significant for refractory venous stasis ulcers of the bilateral lower extremities present for 6 years and morbid obesity. Preoperative venous duplex demonstrated severe venous insufficiency of the superficial and deep systems, but a venous aneurysm was not appreciated. During the high ligation of the right saphenofemoral junction, a 3 × 4 × 5 cm aneurysm was encountered. Repair consisted of aneurysm resection, high ligation of the greater saphenous vein, dissociation of the great saphenous and anterior saphenous veins, and stab phlebectomy of large varicose veins of the thigh and lower leg. The patient recovered uneventfully and experienced complete healing of the venous stasis ulcer in several weeks. Superficial venous aneurysms of the lower extremity are rare and can be often missed on preoperative duplex ultrasound imaging. Large diameter measurements of the proximal greater saphenous vein and obesity increase the risk of misdiagnosing venous aneurysms with duplex imaging; therefore, clinical suspicion must remain high. These aneurysms can be associated with significant symptoms for which repair is indicated.

  2. Cerebral venous circulatory system evaluation by ultrasonography.

    PubMed

    Zavoreo, Iris; Basić-Kes, Vanja; Zadro-Matovina, Lucija; Lisak, Marijana; Corić, Lejla; Cvjeticanin, Timon; Ciliga, Dubravka; Bobić, Tatjana Trost

    2013-06-01

    Venous system can be classified as pulmonary veins, systemic veins and venous sinuses that are present only within the skull. Cerebral venous system is divided into two main parts, the superficial and the deep system. The main assignment of veins is to carry away deoxygenated blood and other maleficient materials from the tissues towards the heart. Veins have thinner walls and larger lumina than arteries. Between 60% and 70% of the total blood volume is found in veins. The major factors that influence venous function are the respiratory cycle, venous tone, the function of the right heart, gravity, and the muscle pump. Venous system, in general, can be presented by selective venography, Doppler sonography, computed tomography (CT) venography and magnetic resonance (MR) venography, and cerebral venous system can be displayed by selective venography, cerebral CT venography, cerebral MR venography, and specialized extracranial and transcranial Doppler sonography. The aim of this paper is to show the possibilities of intracranial and extracranial ultrasound evaluation of the head and neck venous circulation and chronic cerebrospinal venous insufficiency as one of the most common pathologies evaluated as part of neurodegenerative processes in the central nervous system.

  3. Normal venous anatomy and physiology of the lower extremity.

    PubMed

    Notowitz, L B

    1993-06-01

    Venous disease of the lower extremities is common but is often misunderstood. It seems that the focus is on the exciting world of arterial anatomy and pathology, while the topic of venous anatomy and pathology comes in second place. However, venous diseases such as chronic venous insufficiency, leg ulcers, and varicose veins affect much of the population and may lead to disability and death. Nurses are often required to answer complex questions from the patients and his or her family about the patient's disease. Patients depend on nurses to provide accurate information in terms they can understand. Therefore it is important to have an understanding of the normal venous system of the legs before one can understand the complexities of venous diseases and treatments. This presents an overview of normal venous anatomy and physiology.

  4. Characterization of Bacterial Communities in Venous Insufficiency Wounds by Use of Conventional Culture and Molecular Diagnostic Methods▿

    PubMed Central

    Tuttle, Marie S.; Mostow, Eliot; Mukherjee, Pranab; Hu, Fen Z.; Melton-Kreft, Rachael; Ehrlich, Garth D.; Dowd, Scot E.; Ghannoum, Mahmoud A.

    2011-01-01

    Microbial infections delay wound healing, but the effect of the composition of the wound microbiome on healing parameters is unknown. To better understand bacterial communities in chronic wounds, we analyzed debridement samples from lower-extremity venous insufficiency ulcers using the following: conventional anaerobic and aerobic bacterial cultures; the Ibis T5000 universal biosensor (Abbott Molecular); and 16S 454 FLX titanium series pyrosequencing (Roche). Wound debridement samples were obtained from 10 patients monitored clinically for at least 6 months, at which point 5 of the 10 sampled wounds had healed. Pyrosequencing data revealed significantly higher bacterial abundance and diversity in wounds that had not healed at 6 months. Additionally, Actinomycetales was increased in wounds that had not healed, and Pseudomonadaceae was increased in wounds that had healed by the 6-month follow-up. Baseline wound surface area, duration, or analysis by Ibis or conventional culture did not reveal significant differences between wounds that healed after 6 months and those that did not. Thus, pyrosequencing identified distinctive baseline characteristics of wounds that did not heal by the 6-month follow-up, furthering our understanding of potentially unique microbiome characteristics of chronic wounds. PMID:21880958

  5. Use of 16S rRNA sequencing and quantitative PCR to correlate venous leg ulcer bacterial bioburden dynamics with wound expansion, antibiotic therapy, and healing

    PubMed Central

    Sprockett, Daniel D.; Ammons, Christine G.; Tuttle, Marie S.

    2016-01-01

    Clinical diagnosis of infection in chronic wounds is currently limited to subjective clinical signs and culture-based methods that underestimate the complexity of wound microbial bioburden as revealed by DNA-based microbial identification methods. Here, we use 16S rRNA next generation sequencing and quantitative polymerase chain reaction to characterize weekly changes in bacterial load, community structure, and diversity associated with a chronic venous leg ulcer over the 15-week course of treatment and healing. Our DNA-based methods and detailed sampling scheme reveal that the bacterial bioburden of the wound is unexpectedly dynamic, including changes in the bacterial load and community structure that correlate with wound expansion, antibiotic therapy, and healing. We demonstrate that these multidimensional changes in bacterial bioburden can be summarized using swabs taken prior to debridement, and therefore, can be more easily collected serially than debridement or biopsy samples. Overall, this case illustrates the importance of detailed clinical indicators and longitudinal sampling to determine the pathogenic significance of chronic wound microbial dynamics and guide best use of antimicrobials for improvement of healing outcomes. PMID:25902876

  6. What are the keys to successful adrenal venous sampling (AVS) in patients with primary aldosteronism?

    PubMed

    Young, William F; Stanson, Anthony W

    2009-01-01

    Adrenal venous sampling (AVS) is the criterion standard to distinguish between unilateral and bilateral adrenal disease in patients with primary aldosteronism. The keys to successful AVS include appropriate patient selection, careful patient preparation, focused technical expertise, defined protocol, and accurate data interpretation. The use of AVS should be based on patient preferences, patient age, clinical comorbidities, and the clinical probability of finding an aldosterone-producing adenoma. AVS is optimally performed in the fasting state in the morning. AVS is an intricate procedure because the right adrenal vein is small and may be difficult to locate - the success rate depends on the proficiency of the angiographer. The key factors that determine the successful catheterization of both adrenal veins are experience, dedication and repetition. With experience, and focusing the expertise to 1 or 2 radiologists at a referral centre, the AVS success rate can be as high as 96%. A centre-specific, written protocol is mandatory. The protocol should be developed by an interested group of endocrinologists, radiologists and laboratory personnel. Safeguards should be in place to prevent mislabelling of the blood tubes in the radiology suite and to prevent sample mix-up in the laboratory.

  7. Effect of venous stenting on intracranial pressure in idiopathic intracranial hypertension.

    PubMed

    Matloob, Samir A; Toma, Ahmed K; Thompson, Simon D; Gan, Chee L; Robertson, Fergus; Thorne, Lewis; Watkins, Laurence D

    2017-08-01

    Idiopathic intracranial hypertension (IIH) is characterised by an increased intracranial pressure (ICP) in the absence of any central nervous system disease or structural abnormality and by normal CSF composition. Management becomes complicated once surgical intervention is required. Venous sinus stenosis has been suggested as a possible aetiology for IIH. Venous sinus stenting has emerged as a possible interventional option. Evidence for venous sinus stenting is based on elimination of the venous pressure gradient and clinical response. There have been no studies demonstrating the immediate effect of venous stenting on ICP. Patients with a potential or already known diagnosis of IIH were investigated according to departmental protocol. ICP monitoring was performed for 24 h. When high pressures were confirmed, CT venogram and catheter venography were performed to look for venous stenosis to demonstrate a pressure gradient. If positive, venous stenting would be performed and ICP monitoring would continue for a further 24 h after deployment of the venous stent. Ten patients underwent venous sinus stenting with concomitant ICP monitoring. Nine out of ten patients displayed an immediate reduction in their ICP that was maintained at 24 h. The average reduction in mean ICP and pulsatility was significant (p = 0.003). Six out of ten patients reported a symptomatic improvement within the first 2 weeks. Venous sinus stenting results in an immediate reduction in ICP. This physiological response to venous stenting has not previously been reported. Venous stenting could offer an alternative treatment option in correctly selected patients with IIH.

  8. A Study to Determine the Evolution of Advances in Medical Technology Expected in the Next 25 Years and Possible Impacts on Coast Guard Operations and Support Programs.

    DTIC Science & Technology

    1980-05-01

    abnormalities in pressure tracings of the systemic, the central venous or pulmonary arterial circulation. At some sites (especially the Latter-Day Saints...accurate measurement of central venous pressure has been by direct venous cannulation. However, a group of Swiss doctors has extended the principle of... venous stop flow pressure to develop a noninvasive method of measuring central venous pressure. The method consists of venous auscultation at the thoracic

  9. Hepatic venous connection to a persistent inferior caval vein in left isomerism.

    PubMed

    Guenthard, J; Carvalho, J S; Anderson, R H; Rigby, M L

    1990-09-01

    In 22 cases of left atrial isomerism studied at the Brompton Hospital, four cases were found to have an unusual arrangement of the abdominal vessels. There was persistence of an inferior caval vein, partially anomalous hepatic venous connection and additional continuation of part of the venous return from the lower body through the azygos venous system. This venous pattern had surgical implications in our index case, since redirection of the inferior caval venous return was necessary.

  10. Improved black-blood imaging using DANTE-SPACE for simultaneous carotid and intracranial vessel wall evaluation

    PubMed Central

    Xie, Yibin; Yang, Qi; Xie, Guoxi; Pang, Jianing; Fan, Zhaoyang; Li, Debiao

    2015-01-01

    Purpose The purpose of this work is to develop a 3D black-blood imaging method for simultaneously evaluating carotid and intracranial arterial vessel wall with high spatial resolution and excellent blood suppression with and without contrast enhancement. Methods DANTE preparation module was incorporated into SPACE sequence to improve blood signal suppression. Simulations and phantom studies were performed to quantify image contrast variations induced by DANTE. DANTE-SPACE, SPACE and 2D TSE were compared for apparent SNR, CNR and morphometric measurements in fourteen healthy subjects. Preliminary clinical validation was performed in six symptomatic patients. Results Apparent residual luminal blood was observed in 5 (pre-CE) and 9 (post-CE) subjects with SPACE, and only 2 (post-CE) subjects with DANTE-SPACE. DANTE-SPACE showed 31% (pre-CE) and 100% (post-CE) improvement in wall-to-blood CNR over SPACE. Vessel wall area measured from SPACE was significantly larger than that from DANTE-SPACE due to possible residual blood signal contamination. In patients DANTE-SPACE showed the potential to detect vessel wall dissection and identify plaque components. Conclusion DANTE-SPACE significantly improved arterial and venous blood suppression compared with SPACE. Simultaneous high-resolution carotid and intracranial vessel wall imaging to potentially identify plaque components was feasible with scan time under 6 minutes. PMID:26152900

  11. Mechanisms controlling the oxygen consumption in experimentally induced hypochloremic alkalosis in calves.

    PubMed

    Cambier, Carole; Clerbaux, Thierry; Amory, Hélène; Detry, Bruno; Florquin, Sandra; Marville, Vincent; Frans, Albert; Gustin, Pascal

    2002-01-01

    The study was carried out on healthy Friesian calves (n = 10) aged between 10 and 30 days. Hypochloremia and alkalosis were induced by intravenous administration of furosemide and isotonic sodium bicarbonate. The venous and arterial blood samples were collected repeatedly. 2,3-diphosphoglycerate (2,3-DPG), hemoglobin and plasmatic chloride concentrations were determined. The red blood cell chloride concentration was also calculated. pH, PCO2 and PO2 were measured in arterial and mixed venous blood. The oxygen equilibrium curve (OEC) was measured in standard conditions. The correspondence of the OEC to the arterial and mixed venous compartments was calculated, taking blood temperature, pH and PCO2 values into account. The oxygen exchange fraction (OEF%), corresponding to the degree of blood desaturation between the arterial and mixed venous compartments and the amount of oxygen released at the tissue level by 100 mL of blood (OEF Vol%) were calculated from the arterial and mixed venous OEC, combined with PO2 and hemoglobin concentration. Oxygen delivery (DO2) was calculated using the arterial oxygen content, the cardiac output measured by thermodilution, and the body weight of the animal. The oxygen consumption (VO2) was derived from the cardiac output, OEF Vol% and body weight values. Despite the plasma hypochloremia, the erythrocyte chloride concentration was not influenced by furosemide and sodium bicarbonate infusion. Due to the alkalosis-induced increase in the 2,3-DPG, the standard OEC was shifted to the right, allowing oxygen to dissociate from hemoglobin more rapidly. These changes opposed the increased affinity of hemoglobin for oxygen induced by alkalosis. Moreover, respiratory acidosis, hemoconcentration, and the slight decrease in the partial oxygen pressure in mixed venous blood (Pvo2) tended to improve the OEF Vol% and maintain the oxygen consumption in a physiological range while the cardiac output, and the oxygen delivery were significantly decreased. It may be concluded that, despite reduced oxygen delivery, oxygen consumption is maintained during experimentally induced hypochloremic alkalosis in healthy 10-30 day old calves.

  12. Effect of Vacuum on Venous Drainage: an Experimental Evaluation on Pediatric Venous Cannulas and Tubing Systems.

    PubMed

    Vida, V L; Bhattarai, A; Speggiorin, S; Zanella, F; Stellin, G

    2014-01-01

    To observe how vacuum assisted venous drainage (VAVD) may influence the flow in a cardiopulmonary bypass circuit with different size of venous lines and cannulas. The experimental circuit was assembled to represent the cardiopulmonary bypass circuit routinely used during cardiac surgery. Wall suction was applied directly, modulated and measured into the venous reservoir. The blood flow was measured with a flow-meter positioned on the venous line. The circuit prime volume was replaced with group O date expired re-suspended red cells and Plasmalyte 148 to a hematocrit of 28% to 30%. In an open circuit with gravity siphon venous drain, angled cannulae drain more than straight ones regardless the amount of suction applied to the venous line (16 Fr straight cannula (S) drains 90 ml/min less than a 16 Fr angled (A) with a siphon gravity). The same flow can be obtained with lower cannula size and higher suction (i.e. 12 A with and -30 mmHg). Tables have been created to list how the flow varies according to the size of the cannulas, the size of the venous tubes, and the amount of suction applied to the system. Vacuum assisted venous drainage allows the use of smaller cannulae and venous lines to maintain a good venous return, which is very useful during minimally invasive approaches. The present study should be considered as a preliminary attempt to create a scientific-based starting point for a uniform the use of VAVD.

  13. External jugular venous pressure as an alternative to conventional central venous pressure in right lobe donor hepatectomies.

    PubMed

    Abdullah, Mohamed Hussein; Soliman, Hossam El Deen; Morad, Wessam Saber

    2011-12-01

    Many centers have adopted central vein cannulation both for central venous pressure monitoring and fluid administration for right hepatectomy in living-liver donors. However, use of central venous catheters is associated with adverse events that are hazardous to patients and expensive to treat. This study sought to examine the use of external jugular venous pressure as an alternative to conventional central venous pressure in right lobe donor hepatectomies Forty ASA grade I adult living liver-donors without a known history of significant cardiac or pulmonary diseases were enrolled in this prospective observational study. Paired measurement of venous pressures (external jugular venous pressure and internal jugular venous pressure) were taken at the following times: after induction of anesthesia, 30 minutes after skin incision, during right lobe mobilization (every 15 minutes), during hepatic transaction (every 15 minutes), after right lobe resection (every 15 minutes), and after abdominal closure. Paired measurements were equal in 47.5%, 53.5%, 61.5%, 46.3%, and 52.5% for after induction, after skin incision, right lobe mobilization, right lobe transection, after resection, and before abdominal closure periods. However, all measurements were within acceptable limits of bias measurements (± 2 mm Hg). Central venous pressure catheter placement can be avoided and replaced by a less-invasive method such as external jugular venous pressure (which gave an acceptable estimate of central venous pressure in all phases of right lobe resection) in living-donor liver transplant and allowed equivalent monitor even during fluid restriction phases.

  14. External Application of Traditional Chinese Medicine for Venous Ulcers: A Systematic Review and Meta-Analysis

    PubMed Central

    Li, Xin; Xiao, Qing-qing; Ze, Kan; Li, Su; Wang, Yi-fei; Zhou, Min; Yang, Qin-tong; Li, Fu-lun; Li, Bin

    2015-01-01

    Objective. To evaluate the effectiveness of external application of traditional Chinese medicine (EA-TCM) on venous ulcers. Methods. Seven databases were searched until April 2015 for randomized controlled trials (RCTs) of EA-TCM for venous ulcers. Risk of bias was assessed using Cochrane Handbook guidelines. Study outcomes were presented as risk ratios (RRs) for dichotomous data or mean differences (MDs) for continuous data. Results. Sixteen of 193 potentially relevant trials met the inclusion criteria; however, their methodological qualities were low. Comparison of the same intervention strategies revealed significant differences in total effectiveness rates between EA-TCM and conventional therapy groups (RR = 1.22, 95% confidence interval [CI] = 1.16–1.29, and P < 0.00001). Compared to conventional therapy, EA-TCM combined with conventional therapy had a superior total effectiveness rate (RR = 1.11, 95% CI = 1.04–1.19, and P = 0.003). There were no significant differences in recurrence rates during followup and final pain measurements between the experimental and those in the control groups (RR = 0.86, 95% CI = 0.31–2.39, and P = 0.85; MD −0.75, 95% CI = −2.15–0.65, and P = 0.29). Conclusion. The evidence that EA-TCM is an effective treatment for venous ulcers is encouraging, but not conclusive due to the low methodological quality of the RCTs. Therefore, more high-quality RCTs with larger sample sizes are required. PMID:26435725

  15. [Hirudo medicinalis-leech applications in plastic and reconstructive microsurgery--a literature review].

    PubMed

    Knobloch, K; Gohritz, A; Busch, K; Spies, M; Vogt, P M

    2007-04-01

    Medical leech therapy has enjoyed a renaissance in the world of reconstructive microsurgery during recent years. Especially venous congestion is decreased using hirudo medicinalis application such as following replantation of amputated fingers or congested flaps. They provide a temporary relief to venous engorgement whilst venous drainage is re-established. Living in symbiosis with Aeromonas hydrophila, who can digest the sixfold blood meal related to their body weight, and a broad number of anticoagulant agents such as the thrombin inhibitor hirudin, apyrase as well as collagenase, hyaluronidase, Factor Xa inhibitor and fibrinase I and II, leeches decrease venous congestion. Laser Doppler flowmetry could demonstrate a significant increase in superficial skin perfusion following leech application 16 mm around the biting zone. Following the initial blood meal accounting for about 2.5 ml, the anticoagulant effect of the various leeches enzymes follows within the next 5-6 hours, which both account for the beneficial effects. Infection associated with leech therapy is a documented complication of leech application, with reported incidences ranging from 2.4 to 20 % and a chinolone antibiotic is currently recommended to face the potential Aeromonas hydrophila infection. Anemia is a second adverse effect during medicinal leech application which has to be taken account with repetitive blood samples. Besides the successful applications of leeches in various applications in plastic and reconstructive microsurgery, randomized-controlled trials are pending to elucidate the value of hirudo medicinalis according to evidence-based criteria above from case series and case studies.

  16. Risk score to predict the outcome of patients with cerebral vein and dural sinus thrombosis.

    PubMed

    Ferro, José M; Bacelar-Nicolau, Helena; Rodrigues, Teresa; Bacelar-Nicolau, Leonor; Canhão, Patrícia; Crassard, Isabelle; Bousser, Marie-Germaine; Dutra, Aurélio Pimenta; Massaro, Ayrton; Mackowiack-Cordiolani, Marie-Anne; Leys, Didier; Fontes, João; Stam, Jan; Barinagarrementeria, Fernando

    2009-01-01

    Around 15% of patients die or become dependent after cerebral vein and dural sinus thrombosis (CVT). We used the International Study on Cerebral Vein and Dural Sinus Thrombosis (ISCVT) sample (624 patients, with a median follow-up time of 478 days) to develop a Cox proportional hazards regression model to predict outcome, dichotomised by a modified Rankin Scale score >2. From the model hazard ratios, a risk score was derived and a cut-off point selected. The model and the score were tested in 2 validation samples: (1) the prospective Cerebral Venous Thrombosis Portuguese Collaborative Study Group (VENOPORT) sample with 91 patients; (2) a sample of 169 consecutive CVT patients admitted to 5 ISCVT centres after the end of the ISCVT recruitment period. Sensitivity, specificity, c statistics and overall efficiency to predict outcome at 6 months were calculated. The model (hazard ratios: malignancy 4.53; coma 4.19; thrombosis of the deep venous system 3.03; mental status disturbance 2.18; male gender 1.60; intracranial haemorrhage 1.42) had overall efficiencies of 85.1, 84.4 and 90.0%, in the derivation sample and validation samples 1 and 2, respectively. Using the risk score (range from 0 to 9) with a cut-off of >or=3 points, overall efficiency was 85.4, 84.4 and 90.1% in the derivation sample and validation samples 1 and 2, respectively. Sensitivity and specificity in the combined samples were 96.1 and 13.6%, respectively. The CVT risk score has a good estimated overall rate of correct classifications in both validation samples, but its specificity is low. It can be used to avoid unnecessary or dangerous interventions in low-risk patients, and may help to identify high-risk CVT patients. (c) 2009 S. Karger AG, Basel.

  17. A survey of current practice of vascular surgeons in venous disease management.

    PubMed

    Bush, Ruth L; Gloviczki, Peter

    2013-01-01

    Acute venous thromboembolism and chronic venous diseases are common conditions that affect a large proportion of the United States population. The diagnosis of venous disease has improved, and the treatment options have rapidly evolved over the past decade. To date, it is unclear to what extent vascular surgeons have become involved in the modern management of venous disorders. This survey was undertaken to explore the current interest and practice of vascular surgeons in the contemporary care of venous disease. A survey was administered via a web-based platform to active and candidate members of the Society for Vascular Surgery (SVS). The survey included 30 questions investigating the characteristics of venous surgeons and scope of venous practice. Open-ended questions were also included for commentary. A total of 1879 surveys were sent to SVS members nationwide, and 385 members participated (response rate of 20.5%). The participants were mostly men (89.6%) with 37.7% practicing in an academic setting and 59.2% in private practice. The respondents treated superficial veins (92.9%) and deep veins (85.8%) in clinical practice, with 89.9% having their own vascular laboratory. A wide spectrum of interventions for superficial (91.9%), deep (85.8%), and perforator veins (52.7% endovenous, 19.4% subfascial endoscopic perforator surgery) are being performed by respondents. Only 26.2% had learned endovenous thermal ablation in their training program; however, over 96% of those performing venous interventions utilized this technique. Overall, the majority (85.5%) devoted 50% or less of practice to venous disorders. Respondents indicated that limitations to expansion of vein practices mainly involved challenges with third party payers, local competition, and existing large volumes of arterial interventions needing to be performed. Despite the widespread incorporation of venous disease into current vascular practices, 66.1% are not members of the American Venous Forum (AVF) or other venous society. Many believe there is still a lack of standardization of care and guidelines for venous disease. The care of patients with venous disease has become more widespread among SVS members, with most offering both deep and superficial venous interventions as well as incorporation of minimally invasive techniques into their treatment armamentarium. Dissemination and incorporation of protocols and guidelines into clinical practice as well as postgraduate courses in venous disease may be areas in which the SVS could facilitate members' involvement in the care of patients with venous disease. Published by Elsevier Inc.

  18. Three-dimensional venous anatomy of the dermis observed using stereography

    PubMed Central

    Imanishi, Nobuaki; Kishi, Kazuo; Chang, Hak; Nakajima, Hideo; Aiso, Sadakazu

    2008-01-01

    Veins of the dermis have been investigated mainly by histological methods in the fields of anatomy and histology, and a large number of schemata of the veins have been depicted in a variety of textbooks. However, the schemata are usually two-dimensional and it is therefore difficult to envisage the actual vasculature of the dermal veins. In this study, we performed a stereographic study of the skin of three fresh cadavers that had been injected with radio-opaque dye, which was dispersed throughout the entire body. A venous network consisting of venous polygons of various sizes existed just under the dermis or in the deep zone of the dermis, which is generally called the subdermal venous plexus. There were many small vessels towards the inside of each venous polygon, and most of them ascended, branching off stereoscopically. Those branches anastomosed with each other, and they formed the dermal and subpapillary venous plexuses. However, there was little vascular connection between dermal venous plexuses of different venous polygons. The characteristic structure of the dermal venous plexus has been considered to bring about venous congestion of the skin in various clinical situations. PMID:18422525

  19. Radionuclide plethysmography and Tc-99m red blood cell venography in venous thrombosis: comparison with contrast venography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Singer, I.; Royal, H.D.; Uren, R.F.

    1984-01-01

    Radionuclide plethysmography (RPG) is a new technique that uses Tc-99m labelled red blood cells to ascertain changes in venous volumes by detecting the change in counts in response to the inflation and deflation of proximal thigh cuffs. Diagnosis of ileofemoral venous occlusion is possible using this technique, which also provides kinetic data of venous outflow. A range of normal values was defined in 19 subjects for per cent change in venous capacitance and venous outflow. Twenty-one patients with suspected deep venous thrombosis were studied prospectively using RPG, radionuclide venography (RV), and contrast venography (CV) to establish the usefulness of RPGmore » alone and in combination with RV in the diagnosis of deep venous thrombosis. RPG proved to be a reliable technique for the diagnosis of ileofemoral venous thrombosis (sensitivity, 91%; specificity, 100%). RV was less sensitive (73%) and less specific (93%) in diagnosing that condition. When RPG is used as the criterion for the detection of ileofemoral vein thrombosis and RV is used as the criterion for the detection of calf vein thrombosis, the combined techniques show improved sensitivity (92%) and specificity (93%) for the detection of all deep venous thromboses.« less

  20. Prospective evaluation of chronic venous insufficiency based on foot venous pressure measurements and air plethysmography findings.

    PubMed

    Fukuoka, Masato; Sugimoto, Takaki; Okita, Yutaka

    2003-10-01

    The purpose of this study was to evaluate lower extremity venous function in patients with chronic venous insufficiency, with foot venous pressure (FVP) measurements and air plethysmography (APG). Eighty-five limbs of 63 patients with a history of chronic venous insufficiency (CVI) from 1995 to 1999 were studied. FVP parameters studied included ambulatory venous pressure (AVP), percent decrease in FVP with manual calf compression (%drop), ratio of increase in FVP over 4 seconds after release of compression (4SR%), and time to 90% recovery of FVP were measured. APG parameters studied included functional venous volume, 90% refilling time (VFT90), venous filling index, ejection fraction, and residual volume fraction. Venous filling index and 90% refilling time were significantly decreased in limbs with stasis syndrome compared with the control group. AVP, %drop, and 4SR% also showed significantly decrease in limbs with stasis syndrome compared with those without it. AVP, %drop, and 4SR% were significantly different for the primary group compared with the secondary group, whereas no differences were found with regard to any APG parameter. APG enables prediction of the presence of CVI, whereas FVP measurements are more useful for evaluation of clinical severity of CVI.

  1. Medical management of venous ulcers.

    PubMed

    Pascarella, Luigi; Shortell, Cynthia K

    2015-03-01

    Venous disease is the most common cause of chronic leg ulceration and represents an advanced clinical manifestation of venous insufficiency. Due to their frequency and chronicity, venous ulcers have a high socioeconomic impact, with treatment costs accounting for 1% of the health care budget in Western countries. The evaluation of patients with venous ulcers should include a thorough medical history for prior deep venous thrombosis, assessment for an hypercoagulable state, and a physical examination. Use of the CEAP (clinical, etiology, anatomy, pathophysiology) Classification System and the revised Venous Clinical Severity Scoring System is strongly recommended to characterize disease severity and assess response to treatment. This venous condition requires lifestyle modification, with affected individuals performing daily intervals of leg elevation to control edema; use of elastic compression garments; and moderate physical activity, such as walking wearing below-knee elastic stockings. Meticulous skin care, treatment of dermatitis, and prompt treatment of cellulitis are important aspects of medical management. The pharmacology of chronic venous insufficiency and venous ulcers include essentially two medications: pentoxifylline and phlebotropic agents. The micronized purified flavonoid fraction is an effective adjunct to compression therapy in patients with large, chronic ulceration. Copyright © 2015 Elsevier Inc. All rights reserved.

  2. Location of the Central Venous Catheter Tip With Bedside Ultrasound in Young Children: Can We Eliminate the Need for Chest Radiography?

    PubMed

    Alonso-Quintela, Paula; Oulego-Erroz, Ignacio; Rodriguez-Blanco, Silvia; Muñiz-Fontan, Manoel; Lapeña-López-de Armentia, Santiago; Rodriguez-Nuñez, Antonio

    2015-11-01

    To compare the use of bedside ultrasound and chest radiography to verify central venous catheter tip positioning. Prospective observational study. PICU of a university hospital. Patients aged 0-14 who required a central venous catheter. None. Central venous catheter tip location was confirmed by ultrasound and chest radiography. Central venous catheters were classified as intra-atrial or extra-atrial according to their positions in relation to the cavoatrial junction. Central venous catheters located outside the vena cava were considered malpositioned. The distance between the catheter tip and the cavoatrial junction was measured. The time elapsed from image capture to interpretation was recorded. Fifty-one central venous catheters in 40 patients were analyzed. Chest radiography and ultrasound results agreed 94% of the time (κ coefficient, 0.638; p < 0.001) in determining intra-atrial and extra-atrial locations and 92% of the time in determining the diagnosis of central venous catheter malposition (κ coefficient, 0.670; p < 0.001). Chest radiography indicated a greater distance between the central venous catheter tip and the cavoatrial junction than measured by ultrasound, with a mean difference of 0.38 cm (95% CI, +0.27, +0.48 cm). Three central venous catheters were classified as extra-atrial by chest radiography but as intra-atrial by ultrasound. To locate the central venous catheter tip, ultrasound required less time than chest radiography (22.96 min [20.43 min] vs 2.23 min [1.06 min]; p < 0.001). Bedside ultrasound showed a good agreement with chest radiography in detecting central venous catheter tip location and revealing incorrect positions. Ultrasound could be a preferable method for routine verification of central venous catheter tip and can contribute to increased patient safety.

  3. Central venous catheter-associated bloodstream infections in a pediatric intensive care unit: effect of the location of catheter insertion.

    PubMed

    Krishnaiah, Anil; Soothill, James; Wade, Angie; Mok, Quen Q; Ramnarayan, Padmanabhan

    2012-05-01

    To compare the rate of central venous catheter-associated bloodstream infections between pediatric intensive care unit admissions where central venous catheters were inserted within the same hospital (internal central venous catheters) and those where central venous catheters were inserted before transfer from other hospitals (external central venous catheters). Retrospective analysis of prospectively collected data. A tertiary care pediatric intensive care unit in London, UK. Consecutive pediatric intensive care unit admissions between May 2007 and March 2009. None. Catheter-associated bloodstream infections were identified using a widely accepted surveillance definition. The rate and time to occurrence of catheter-associated bloodstream infection were compared between internal and external nontunneled central venous catheters. A multilevel Cox-regression model was used to study the association between location of central venous catheter insertion and time to catheter-associated bloodstream infection. In total, 382 central venous catheters were studied (245 internal; 137 external) accounting for a total of 1,737 central venous catheter days. There was a higher catheter-associated bloodstream infection incidence density among external central venous catheters (23.1 [95% confidence interval 11.0-35.2] vs. 9.7 [95% confidence interval 3.9-15.5] per 1,000 catheter-days). Multivariable analyses demonstrated higher infection risk with external central venous catheters (hazard ratio 2.65 [95% confidence interval 1.18-5.96]) despite adjustment for confounding variables. The rate of catheter-associated bloodstream infections in the pediatric intensive care unit is significantly affected by external insertion of the central venous catheter. Future interventions to reduce nosocomial infections on pediatric intensive care units will need to be specifically targeted at this high-risk patient group.

  4. Immune phenomena in neonates of women with depression during pregnancy: a case-control study.

    PubMed

    Kianbakht, Saeed; Mashhadi, Esmat; Jamillian, Hamid Reza; Ghazavi, Ali

    2013-04-01

    To evaluate the effects of major and minor depression during pregnancy on the maternal and neonatal immunities. Peripheral venous blood from depressed women and cord venous blood from their neonates taken simultaneously and immediately after parturition were used. The serum levels of immunoglobulins IgG, IgM and IgA and complements C3 and C4 were determined through single radial immunodiffusion with the kits manufactured by the Biogen company (Mashhad, Iran). To reduce error, all the ring diameters were measured by one experimenter unaware of the study groups. The blood leukocyte and lymphocyte counts and lymphocyte percentage were determined with a H1 counter and for more accuracy also with a Hycel counter. The immune parameters of depressed women were not significantly different from controls. The lymphocyte counts in neonates of women with major and minor depression were increased, whereas ratio of the cord blood level of IgG to the maternal blood level of IgG in neonates of women with major depression were decreased compared to controls. Major depression during pregnancy reduces the prenatal transfer of IgG from mother to neonate. The low prenatal transfer of IgG may have clinical significance, because it can compromise immune competence in neonates.

  5. The effect of acute temperature increases on the cardiorespiratory performance of resting and swimming sockeye salmon (Oncorhynchus nerka).

    PubMed

    Steinhausen, M F; Sandblom, E; Eliason, E J; Verhille, C; Farrell, A P

    2008-12-01

    The mechanism underlying the decrease in aerobic scope in fish at warm temperatures is not fully understood and is the focus of this research. Our study examined oxygen uptake and delivery in resting, swimming and recovering sockeye salmon while water temperature was acutely increased from 15 degrees C to 24 degrees C in 2 degrees C h(-1) increments. Fish swam at a constant speed during the temperature change. By simultaneously measuring oxygen consumption (M(O(2))), cardiac output (Q) and the blood oxygen status of arterial and venous blood, we were able to determine where in the oxygen cascade a limitation appeared when fish stopped sustained swimming as temperature increased. High temperature fatigue of swimming sockeye salmon was not a result of a failure of either oxygen delivery to the gills or oxygen diffusion at the gills because oxygen partial pressure (P(O(2))) and oxygen content (C(O(2))) in arterial blood did not decrease with increasing temperature, as would be predicted for such limitations. Instead, arterial oxygen delivery (Ta(O(2))) was initially hampered due to a failure to adequately increase Q with increasing temperature. Subsequently, lactate appeared in the blood and venous P(O(2)) remained constant.

  6. Maxillary reconstruction with a double-barrel osteocutaneous fibular flap and arteriovenous saphenous loop after a globe-sparing total maxillectomy-A Case Report.

    PubMed

    Chen, Szu-Han; Hung, Kuo-Shu; Lee, Yao-Chou

    2017-05-01

    Maxillary reconstruction using titanium mesh or bone grafts can invite unwanted complications, such as graft resorption, infection, and mesh exposure, especially for patients who require postoperative radiotherapy. Here, we reported a 58-year-old male patient who was diagnosed with maxillary sinus squamous cell carcinoma. The patient received cancer ablation by a globe-sparing total maxillectomy and was immediately reconstructed with a double-barrel osteocutaneous fibular flap to simultaneously restore the alveolar ridge, orbital support, and oro-sinonasal separation. The short pedicle length inherent in the double-barrel design of the fibular flap and the depletion of healthy recipient vessels in the midface after cancer ablation were overcome by creating an arteriovenous saphenous loop in the neck region. Though there was venous congestion on postoperative day 2, the postoperative recovery was uneventful after the revision of the venous anastomoses. During the 6-months follow-up, the outcome was functionally and aesthetically satisfactory. We believe that the double-barrel fibular osteocutaneous flap, which avoids using titanium mesh and bone grafts, may be a viable reconstructive option in cancer patients with globe-sparing total maxillectomy defects, especially for those who require postoperative radiotherapy. © 2015 Wiley Periodicals, Inc. Microsurgery 37:334-338, 2017. © 2015 Wiley Periodicals, Inc.

  7. Reversed differential cyanosis in the newborn: a clinical finding in the supracardiac total anomalous pulmonary venous connection.

    PubMed

    Yap, Shook H; Anania, Nicole; Alboliras, Ernerio T; Lilien, Lawrence D

    2009-04-01

    The newborn can experience two types of differential cyanosis (DC). The common type of DC occurs when oxygen saturation in the right hand is greater than in the foot. The second type of DC, reversed differential cyanosis (RDC), occurs when oxygen saturation is lower in the right hand than in the foot. This phenomenon is observed in transposition of the great arteries (TGA) with patent ductus arteriosis (PDA) and elevated pulmonary vascular resistance or in TGA with PDA and preductal aortic interruption or coarctation. This report describes a case of RDC not previously described involving an infant with supracardiac total anomalous pulmonary venous connection (TAPVC). In supracardiac TAPVC, RDC results from streaming of highly saturated superior vena cava (SVC) blood into the right ventricle, out the main pulmonary artery, through a PDA, and to the descending aorta, with streaming of more desaturated blood from the inferior vena cava (IVC) into the left atrium across the atrial septal defect (ASD)/foramen ovale. Therefore, as part of a neonatal examination to rule out congenital heart disease (CHD), simultaneous pre- and postductal oxygen saturations should be documented. The presence of RDC should initiate immediate full cardiac evaluation for CHD. Supracardiac TAPVC should be included in the differential diagnosis if RDC is observed.

  8. The effects of arterial carbon dioxide partial pressure and sevoflurane on capillary venous cerebral blood flow and oxygen saturation during craniotomy.

    PubMed

    Klein, Klaus Ulrich; Glaser, Martin; Reisch, Robert; Tresch, Achim; Werner, Christian; Engelhard, Kristin

    2009-07-01

    Intraoperative routine monitoring of cerebral blood flow and oxygenation remains a technological challenge. Using the physiological principle of carbon dioxide reactivity of cerebral vasculature, we investigated a recently developed neuromonitoring device (oxygen-to-see, O2C device) for simultaneous measurements of regional cerebral blood flow (rvCBF), blood flow velocity (rvVelo), oxygen saturation (srvO2), and hemoglobin amount (rvHb) at the capillary venous level in patients subjected to craniotomy. Twenty-six neurosurgical patients were randomly assigned to anesthesia with 1.4% or 2.0% sevoflurane end-tidal concentration. After craniotomy, a fiberoptic probe was applied on a macroscopically healthy surface of cerebral tissue next to the site of surgery. Simultaneous measurements in 2 and 8 mm cerebral depth were performed in each patient during lower (35 mm Hg) and higher (45 mm Hg) levels (random order) of arterial carbon dioxide partial pressure (PaCO2). The principle of these measurements relies on the combination of laser-Doppler flowmetry (rvCBF, rvVelo) and photo-spectrometry (srvO2, rvHb). Linear models were fitted to test changes of end points (rvCBF, rvVelo, srvO2, rvHb) in response to lower and higher levels of PaCO2, 1.4% and 2.0% sevoflurane end-tidal concentration, and 2 and 8 mm cerebral depth. RvCBF and rvVelo were elevated by PaCO2 independent of sevoflurane concentration in 2 and 8 mm depth of cerebral tissue (P < 0.001). Higher PaCO2 induced an increase in mean srvO2 from 50% to 68% (P < 0.001). RvVelo (P < 0.001) and srvO2 (P = 0.007) were higher in 8 compared with 2 mm cerebral depth. RvHb was not influenced by alterations in PaCO2 but positively correlated to sevoflurane concentration (P = 0.005). Increases in rvCBF and rvVelo by PaCO2 suggest preserved hypercapnic vasodilation under anesthesia with sevoflurane 1.4% and 2.0% end-tidal concentration. A consecutive increase in srvO2 implies that cerebral arteriovenous difference in oxygen was decreased by elevated PaCO2. Unchanged levels of rvHb signify that there was no blood loss during measurements. Data suggest that the device allows detection of local changes in blood flow and oxygen saturation in response to different PaCO2 levels in predominant venous cerebral microvessels.

  9. Current concepts in repair of extremity venous injury.

    PubMed

    Williams, Timothy K; Clouse, W Darrin

    2016-04-01

    Extremity venous injury management remains controversial. The purpose of this communication is to offer perspective as well as experiential and technical insight into extremity venous injury repair. Available literature is reviewed and discussed. Historical context is provided. Indication, the decision process for repair, including technical conduct, is delineated. In particular, the authors' experiences in both civilian and wartime injury are used for perspective. Extremity venous injury repair was championed within data from the Vietnam Vascular Registry. However, patterns of extremity venous injury differ between combat and civilian settings. Since Vietnam, civilian descriptive series opine the benefits and potential complications associated with both venous injury repair and ligation. These surround extremity edema, chronic venous insufficiency, thromboembolism, and limb loss. Whereas no clear superiority in either approach has been identified to date, there appears to be no increased risk of pulmonary embolism or chronic venous changes with repair. Newer data from the wars in Iraq and Afghanistan and meta-analysis have reinforced this and also have suggested limb salvage benefit for extremity venous repair in combined arterial and venous injuries in modern settings. The patient's physiologic state and associated injury drive five triage categories suggesting vein injury management. Vein repair thrombosis occurs in a significant proportion, yet many recanalize and possibly have a positive impact on limb venous return. Further, early decompression favors reduced blood loss, acute edema, and inflammation, supporting collateral development. Large soft tissue injury minimizing collateral capacity increases the importance of repair. Constructs of repair are varied with modest differences in patency. Venous shunting is feasible, but specific roles remain nebulous. An aggressive posture toward extremity venous injury repair seems justified today because of the likely role in reducing venous hypertensive sequelae as well as a potential role in limb salvage. Appropriate triage selection for extremity vein repair is essential. Copyright © 2016 Society for Vascular Surgery. All rights reserved.

  10. Venous thromboembolism in adults with sickle cell disease: A serious and under-recognized complication

    PubMed Central

    Naik, Rakhi P.; Streiff, Michael B.; Haywood, Carlton; Nelson, Julie A.; Lanzkron, Sophie

    2013-01-01

    BACKGROUND Sickle cell disease is recognized as a hypercoagulable state; however the frequency and characteristics of venous thromboembolism in sickle cell patients have not been well-defined. PURPOSE To establish the prevalence and risk factors for venous thromboembolism in a large cohort of patients with sickle cell disease and determine the relationship between venous thromboembolism and mortality. METHODS We performed a cross-sectional study of 404 sickle cell disease patients cared for at the Sickle Cell Center for Adults at Johns Hopkins. Demographic, sickle cell disease-specific comorbidity, and venous thromboembolism data were collected on all patients. RESULTS 101 patients (25%) had a history of venous thromboembolism with a median age at diagnosis of 29.9 years. A history of non-catheter-related venous thromboembolism was found in 18.8% of patients. Sickle variant genotypes conferred a higher risk of non-catheter-related venous thromboembolism compared to sickle cell anemia genotypes (SS/Sβ0) (relative risk (RR) 1.77, 95% confidence interval (CI) 1.18–2.66). Tricuspid regurgitant jet velocity ≥ 2.5 m/s was also associated with non-catheter-related venous thromboembolism (RR 1.65, CI 1.12–2.45). Thirty patients (7.4%) died during the study period. Adjusting for all variables, non-catheter-related venous thromboembolism was independently correlated with death (RR 3.63, CI 1.66–7.92). CONCLUSION Venous thromboembolism is common in adults with sickle cell disease. Sickle variant genotypes and tricuspid regurgitant jet velocity ≥ 2.5m/s are associated with non-catheter-related venous thromboembolism. In addition, non-catheter-related venous thromboembolism appears to be an independent risk factor for death in our cohort. These results suggest that disease-specific prophylaxis and treatment strategies for venous thromboembolism should be investigated in sickle cell disease patients. PMID:23582935

  11. Cranial dural arteriovenous shunts. Part 4. Clinical presentation of the shunts with leptomeningeal venous drainage.

    PubMed

    Baltsavias, Gerasimos; Spiessberger, Alex; Hothorn, Torsten; Valavanis, Anton

    2015-04-01

    Cranial dural arteriovenous fistulae have been classified into high- and low-risk lesions mainly based on the pattern of venous drainage. Those with leptomeningeal venous drainage carry a higher risk of an aggressive clinical presentation. Recently, it has been proposed that the clinical presentation should be considered as an additional independent factor determining the clinical course of these lesions. However, dural shunts with leptomeningeal venous drainage include a very wide spectrum of inhomogeneous lesions. In the current study, we correlated the clinical presentation of 107 consecutive patients harboring cranial dural arteriovenous shunts with leptomeningeal venous drainage, with their distinct anatomic and angiographic features categorized into eight groups based on the "DES" (Directness and Exclusivity of leptomeningeal venous drainage and features of venous Strain) concept. We found that among these groups, there are significant angioarchitectural differences, which are reflected by considerable differences in clinical presentation. Leptomeningeal venous drainage of dural sinus shunts that is neither direct nor exclusive and without venous strain manifested only benign symptoms (aggressive presentation 0%). On the other end of the spectrum, the bridging vein shunts with direct and exclusive leptomeningeal venous drainage and venous strain are expected to present aggressive symptoms almost always and most likely with bleeding (aggressive presentation 91.5%). Important aspects of the above correlations are discussed. Therefore, the consideration of leptomeningeal venous drainage alone, for prediction of the clinical presentation of these shunts appears insufficient. Angiographic analysis based on the above concept, offers the possibility to distinguish the higher- from the lower-risk types of leptomeningeal venous drainage. In this context, consideration of the clinical presentation as an additional independent factor for the prediction of their clinical course seems superfluous and possibly misleading. Topography is connected to the clinical presentation of the dural shunts inasmuch as the former determines the venous anatomy and the angioarchitectural features of the lesions.

  12. Assessing the kidney function parameters glomerular filtration rate and effective renal plasma flow with dynamic FDG-PET/MRI in healthy subjects.

    PubMed

    Geist, Barbara K; Baltzer, Pascal; Fueger, Barbara; Hamboeck, Martina; Nakuz, Thomas; Papp, Laszlo; Rasul, Sazan; Sundar, Lalith Kumar Shiyam; Hacker, Marcus; Staudenherz, Anton

    2018-05-09

    A method was developed to assess the kidney parameters glomerular filtration rate (GFR) and effective renal plasma flow (ERPF) from 2-deoxy-2-[ 18 F]fluoro-D-glucose (FDG) concentration behavior in kidneys, measured with positron emission tomography (PET) scans. Twenty-four healthy adult subjects prospectively underwent dynamic simultaneous PET/magnetic resonance imaging (MRI) examination. Time activity curves (TACs) were obtained from the dynamic PET series, with the guidance of MR information. Patlak analysis was performed to determine the GFR, and based on integrals, ERPF was calculated. Results were compared to intra-individually obtained reference values determined from venous blood samples. Total kidney GFR and ERPF as estimated by dynamic PET/MRI were highly correlated to their reference values (r = 0.88/p < 0.0001 and r = 0.82/p < 0.0001, respectively) with no significant difference between their means. The study is a proof of concept that GFR and ERPF can be assessed with dynamic FDG PET/MRI scans in healthy kidneys. This has advantages for patients getting a routine scan, where additional examinations for kidney function estimation could be avoided. Further studies are required for transferring this PET/MRI method to PET/CT applications.

  13. Anxiety associated with parachute jumping as the cause of blood red-ox balance impairment.

    PubMed

    Kowalczyk, Mateusz; Kozak, Katarzyna; Ciećwierz, Julita; Sienkiewicz, Monika; Kura, Marcin; Jasiak, Łukasz; Kowalczyk, Edward

    2016-12-23

    The aim of the study was to assess the effect of anxiety associated with parachute jumps on selected redox balance parameters in regular soldiers from airborne forces. The study allows estimating whether the paratroopers exposed to high level of mental stress are simultaneously under severe oxidative stress. The investigations were carried out on 46 professional soldiers from airborne forces divided into groups depending on the number of performed parachute jumps. Peripheral venous blood samples were obtained under fasting conditions three times for the determination of selected parameters of red-ox balance: on an ordinary working day, on the day when the jump was performed and on the day after the jump. The time of the performed determinations was to reflect the initial balance of the organism, the state at the moment of stress and its effect on the organism. Our investigations showed lack of differences in characteristics of the activity of antioxidant enzymes (CAT and SOD) in response to mental stress depending on the experience of the investigated group in parachuting. Decrease in GSH-Px activity was demonstrated in response to mental stress in all the investigated groups. The TBARS level was higher in more experienced parachutists. The analysis of changes in selected redox balance parameters may be useful for monitoring anxiety associated with parachute jumps.

  14. Asystole and increased serum myoglobin levels associated with 'packing blackout' in a competitive breath-hold diver.

    PubMed

    Andersson, Johan P A; Linér, Mats H; Jönsson, Henrik

    2009-11-01

    Many competitive breath-hold divers use 'glossopharyngeal insufflation', also called 'lung packing', to overfill their lungs above normal total lung capacity. This increases intrathoracic pressure, decreases venous return, compromises cardiac pumping, and reduces arterial blood pressure, possibly resulting in a syncope breath-hold divers call 'packing blackout'. We report a case with a breath-hold diver who inadvertently experienced a packing blackout. During the incident, an electrocardiogram (ECG) and blood pressure were recorded, and blood samples for determinations of biomarkers of cardiac muscle perturbation (creatine kinase-MB isoenzyme (CK-MB), cardiac troponin-T (TnT), and myoglobin) were collected. The ECG revealed short periods of asystole during the period of 'packing blackout', simultaneous with pronounced reductions in systolic, diastolic, and pulse pressures. Serum myoglobin concentration was elevated 40 and 150 min after the incident, whereas there were no changes in CK-MB or TnT. The ultimate cause of syncope in this diver probably was a decrease in cerebral perfusion following glossopharyngeal insufflation. The asystolic periods recorded in this diver could possibly indicate that susceptible individuals may be put at risk of a serious cardiac incident if the lungs are excessively overinflated by glossopharyngeal insufflation. This concern is further substantiated by the observed increase in serum myoglobin concentration after the event.

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cantone, M.C.

    The interest in biokinetic studies is driven by problems related to the physiopathology of oligoelements, chemical elemental pollution and radioactive release in case of nuclear accidents. The application of stable isotopes as tracers in studies of trace elements in the area of nutritional and food science is particularly attractive and specifically if considering the investigations on the most radiosensitive age groups of the population and the repeated studies on healthy people for the assessment of the bioavailability of different compounds. A tracer method based on stable isotope administration, which combines the simultaneous use of two tracers and proton activation analysismore » is presented. A study aimed to obtain molybdenum biokinetic data in humans was performed. One tracer ({sup 96}Mo) was orally administered and another ({sup 95}Mo) was intravenously injected to two fasting volunteer subjects. Venous blood samples were withdrawn at different postinjection times. The concentration in plasma for both the isotopes was determined by measuring the intensities of the gamma-lines from the technetium radioisotopes produced via (p,n) reactions. In the adopted experimental conditions a minimum detectable concentration of 2 ng isotope/ml plasma was attained. The parameters describing molybdenum kinetics were obtained for the two individuals. Moreover, the investigation was repeated with different tracer amounts for one of the two subjects, in both fasting and non-fasting condition.« less

  16. Risk factors for hospital-associated venous thromboembolism in critically ill children following cardiothoracic surgery or therapeutic cardiac catheterisation.

    PubMed

    Atchison, Christie M; Amankwah, Ernest; Wilhelm, Jean; Arlikar, Shilpa; Branchford, Brian R; Stock, Arabela; Streiff, Michael; Takemoto, Clifford; Ayala, Irmel; Everett, Allen; Stapleton, Gary; Jacobs, Marshall L; Jacobs, Jeffrey P; Goldenberg, Neil A

    2018-02-01

    Paediatric hospital-associated venous thromboembolism is a leading quality and safety concern at children's hospitals. The aim of this study was to determine risk factors for hospital-associated venous thromboembolism in critically ill children following cardiothoracic surgery or therapeutic cardiac catheterisation. We conducted a retrospective, case-control study of children admitted to the cardiovascular intensive care unit at Johns Hopkins All Children's Hospital (St. Petersburg, Florida, United States of America) from 2006 to 2013. Hospital-associated venous thromboembolism cases were identified based on ICD-9 discharge codes and validated using radiological record review. We randomly selected two contemporaneous cardiovascular intensive care unit controls without hospital-associated venous thromboembolism for each hospital-associated venous thromboembolism case, and limited the study population to patients who had undergone cardiothoracic surgery or therapeutic cardiac catheterisation. Odds ratios and 95% confidence intervals for associations between putative risk factors and hospital-associated venous thromboembolism were determined using univariate and multivariate logistic regression. Among 2718 admissions to the cardiovascular intensive care unit during the study period, 65 met the criteria for hospital-associated venous thromboembolism (occurrence rate, 2%). Restriction to cases and controls having undergone the procedures of interest yielded a final study population of 57 hospital-associated venous thromboembolism cases and 76 controls. In a multiple logistic regression model, major infection (odds ratio=5.77, 95% confidence interval=1.06-31.4), age ⩽1 year (odds ratio=6.75, 95% confidence interval=1.13-160), and central venous catheterisation (odds ratio=7.36, 95% confidence interval=1.13-47.8) were found to be statistically significant independent risk factors for hospital-associated venous thromboembolism in these children. Patients with all three factors had a markedly increased post-test probability of having hospital-associated venous thromboembolism. Major infection, infancy, and central venous catheterisation are independent risk factors for hospital-associated venous thromboembolism in critically ill children following cardiothoracic surgery or cardiac catheter-based intervention, which, in combination, define a high-risk group for hospital-associated venous thromboembolism.

  17. Central venous pressure and mean circulatory filling pressure in the dogfish Squalus acanthias: adrenergic control and role of the pericardium.

    PubMed

    Sandblom, Erik; Axelsson, Michael; Farrell, Anthony P

    2006-11-01

    Subambient central venous pressure (Pven) and modulation of venous return through cardiac suction (vis a fronte) characterizes the venous circulation in sharks. Venous capacitance was estimated in the dogfish Squalus acanthias by measuring the mean circulatory filling pressure (MCFP) during transient occlusion of cardiac outflow. We tested the hypothesis that venous return and cardiac preload can be altered additionally through adrenergic changes of venous capacitance. The experiments involved the surgical opening of the pericardium to place a perivascular occluder around the conus arteriosus. Another control group was identically instrumented, but lacked the occluder, and was subjected to the same pharmacological protocol to evaluate how pericardioectomy affected cardiovascular status. Routine Pven was negative (-0.08+/-0.02 kPa) in control fish but positive (0.09+/-0.01 kPa) in the pericardioectomized group. Injections of 5 microg/kg body mass (Mb) of epinephrine and phenylephrine (100 microg/kg Mb) increased Pven and MCFP, whereas isoproterenol (1 microg/kg Mb) decreased both variables. Thus, constriction and relaxation of the venous vasculature were mediated through the respective stimulation of alpha- and beta-adrenergic receptors. Alpha-adrenergic blockade with prazosin (1 mg/kg Mb) attenuated the responses to phenylephrine and decreased resting Pven in pericardioectomized animals. Our results provide convincing evidence for adrenergic control of the venous vasculature in elasmobranchs, although the pericardium is clearly an important component in the modulation of venous function. Thus active changes in venous capacitance have previously been underestimated as an important means of modulating venous return and cardiac performance in this group.

  18. Non-contact imaging of venous compliance in humans using an RGB camera

    NASA Astrophysics Data System (ADS)

    Nakano, Kazuya; Satoh, Ryota; Hoshi, Akira; Matsuda, Ryohei; Suzuki, Hiroyuki; Nishidate, Izumi

    2015-04-01

    We propose a technique for non-contact imaging of venous compliance that uses the red, green, and blue (RGB) camera. Any change in blood concentration is estimated from an RGB image of the skin, and a regression formula is calculated from that change. Venous compliance is obtained from a differential form of the regression formula. In vivo experiments with human subjects confirmed that the proposed method does differentiate the venous compliances among individuals. In addition, the image of venous compliance is obtained by performing the above procedures for each pixel. Thus, we can measure venous compliance without physical contact with sensors and, from the resulting images, observe the spatial distribution of venous compliance, which correlates with the distribution of veins.

  19. Post-thrombotic syndrome and venous disease-specific quality of life in patients with vascular Behçet's disease.

    PubMed

    Alibaz-Oner, Fatma; Aldag, Belgin; Aldag, Mustafa; Unal, A Ugur; Mutiş, Aydan; Toptas, Tayfur; Ergun, Tulin; Direskeneli, Haner

    2016-07-01

    Deep venous thrombosis (DVT) is the most common form of vascular involvement in Behçet's disease (BD). Chronic post-thrombotic syndrome (PTS) develops in up to one-half of patients with DVT and is associated with impaired quality of life (QoL). There are no data on the severity of DVT-related PTS and its effect on QoL in patients with vascular BD (VBD). We aimed to evaluate PTS and venous disease-specific QoL in patients with VBD. This study included 50 patients (41 men, nine women) with VBD and 31 individuals matched for age and gender (22 men, nine women) with DVT associated with non-BD causes. The Villalta scale was used to assess PTS. The Venous Disability Score and the Venous Clinical Severity Score were used for the assessment of venous disease. Venous disease-specific QoL was measured through Venous Insufficiency Epidemiological and Economic Study Quality of Life/Symptom (VEINES-QoL/Sym) questionnaire. The Behçet Syndrome Activity Score (BSAS) questionnaire was used to assess disease activity. We observed a significantly lower risk of PTS together with significantly better VEINES-QoL/Sym, and Venous Disability Score in the VBD group compared with the non-BD group. When VBD patients with PTS were compared with patients without PTS, VEINES-QoL/Sym, and Venous Clinical Severity Score were significantly worse. BSAS was also significantly higher in patients with PTS. An inverse correlation was found between the VEINES-QoL and the BSAS in multivariate analysis. There were no differences between anticoagulant users and nonusers regarding the presence of PTS and scores of all of the venous assessment tools. We found lower PTS risk and better venous disease-specific QoL, symptom severity, and venous disability scores in VBD patients compared with the non-BD group. Venous disease-specific QoL negatively correlated with disease activity. Effective control of vascular inflammation through treatment in VBD might explain lower rates of PTS and better venous QoL outcomes in VBD patients. Our results suggest that successful control of BD activity might decrease the development of PTS, improve venous disease-specific QoL, and prevent relapses in VBD. Copyright © 2016 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  20. [Actual questions about the prevention of venous thromboembolism in cancer patients receiving chemotherapy].

    PubMed

    Losonczy, Hajna; Nagy, Ágnes; Tar, Attila

    2016-02-07

    Cancer patients have a 2-7 fold increased risk of venous thromboembolism compared with the general population and, since 1990, this is associated with significant morbidity and mortality. This review summarizes the current knowledge on venous thromboembolism and cancer. Notably, the risk of venous thromboembolism varies depending on the type and stage of cancer. For instance, pancreatic and brain cancer patients have a higher risk of venous thromboembolism than breast and prostate cancer patients. Moreover, patients with metastatic disease have a higher risk than those with localized tumors. Tumor-derived procoagulant factors, cytokines and growth factors may directly and indirectly enhance venous thromboembolism. Chemotherapy produces ~6,5 fold increase in venous thromboembolism incidence in cancer patients compared to the general population. Prevention of this complication is challenging. The authors review the development of guidelines concerning venous thromboembolism prevention in hospitalized and also in ambulatory cancer patients treated with chemotherapy. Current guidelines recommend the use of low-molecular-weight heparin. Understanding the underlying mechanisms may allow the development of new therapies to safely prevent venous thromboembolism in cancer patients.

  1. Pathophysiology and Toxicokinetic Studies of Blue-Green Algae Intoxication in the Swine Model

    DTIC Science & Technology

    1991-06-26

    perfusion, renal perfusion, and mean arterial and central venous pressures were decreased, and portal pressure increased. Liver iron and hemoglobin indicated...the lethal dose, aortic mean pressure and central venous pressure decreased significantly, while portal venous pressure significantly increased. The...8217" recorded on a poiygraphY and logged on a hemodynamic analyzer.𔄁 Mean aortic, central venous , and portal venous pressures were determined predosing

  2. Safety of Pregnancy After Cerebral Venous Thrombosis: Results of the ISCVT (International Study on Cerebral Vein and Dural Sinus Thrombosis)-2 PREGNANCY Study.

    PubMed

    Aguiar de Sousa, Diana; Canhão, Patrícia; Crassard, Isabelle; Coutinho, Jonathan; Arauz, Antonio; Conforto, Adriana; Béjot, Yannick; Giroud, Maurice; Ferro, José M

    2017-11-01

    Pregnancy is associated with increased risk of venous thrombotic events, including cerebral venous thrombosis. We aimed to study the complications and outcome of subsequent pregnancies in women with previous cerebral venous thrombosis. Follow-up study of women with acute cerebral venous thrombosis at childbearing age included in a previously described cohort (International Study of Cerebral Vein and Dural Sinus Thrombosis). Patients were interviewed by local neurologists to assess rate of venous thrombotic events, pregnancy outcomes, and antithrombotic prophylaxis during subsequent pregnancies. A total of 119 women were included, with a median follow-up of 14 years. Eighty-two new pregnancies occurred in 47 women. In 83% (68 of 82), some form of antithrombotic prophylaxis was given during at least 1 trimester of pregnancy or puerperium. Venous thrombotic events occurred in 3 pregnancies, including 1 recurrent cerebral venous thrombosis. Two of the 3 women were on prophylactic low-molecular-weight heparin at the time of the event. Outcomes of pregnancies were 51 full-term newborns, 9 preterm births, 2 stillbirths, and 20 abortions (14 spontaneous). In women with prior cerebral venous thrombosis, recurrent venous thrombotic events during subsequent pregnancies are infrequent. © 2017 American Heart Association, Inc.

  3. Proximally pedicled medial plantar flap based on superficial venous system alone for venous drainage.

    PubMed

    Wright, Thomas C; Mossaad, Bassem M; Chummun, Shaheel; Khan, Umraz; Chapman, Thomas W L

    2013-07-01

    The proximally pedicled medial plantar flap is well described for coverage of wounds around the ankle and heel. This flap is usually based on the deep venae comitantes for venous drainage, with the superficial veins divided during dissection. Usually any disruption of the deep venous system of the flap would result in abandoning this choice of flap. Venous congestion is a recognised complication of medial plantar flaps. The patient described in this case report had a medial ankle defect with exposed bone, for which a proximally pedicled medial plantar flap was used. As we raised the flap, both venae comitantes of the medial planter artery were found to be disrupted. The flap was raised based on the superficial veins draining into the great saphenous, as the only system for venous drainage, with no evidence of venous congestion. The flap was successfully transposed into the defect and healed with no complications. The proximally pedicled medial plantar flap can safely rely on the superficial venous system alone for drainage. In addition, preserving the superficial veins minimise the risk of venous congestion in this flap. We recommend preservation of superficial venous system when possible. Copyright © 2013 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  4. The complicated role of venous drainage on the survival of arterialized venous flaps

    PubMed Central

    Weng, Weidong; Zhang, Feng; Zhao, Bin; Wu, Zhipeng; Gao, Weiyang; Li, Zhijie; Yan, Hede

    2017-01-01

    The arterialized venous flap (AVF) has been gradually popularized in clinical settings; however, its survival is still inconsistent and the role of venous drainage remains elusive. In this study, we aimed to investigate the role of venous drainage on the flap survival of arterialized venous flaps. An arterialized venous flap was outlined symmetrically in the rabbit abdomen. The arterial perfusion flap with a unilateral vascular pedicle was taken as the control group and three other experimental groups (I, II and III) were designed based on the number of drainage veins (n = 1, 2 and 3 in the three groups, respectively). Compared with the control group, significant venous congestion was noted in all the experimental groups and the most severe one was seen in group I; while no statistical difference was observed between groups II and III. Similar results regarding blood perfusion state, epidermal metabolite levels and flap survival status were obtained among the three groups. These findings suggested that venous drainage is vital in the survival of the flap, but unlike in the arterial perfusion flaps, the problem of venous congestion can only be partially solved by increasing the number of draining veins. Further studies are warranted to gain insight into this complicated issue. PMID:28145882

  5. Significance of pathological positive superior mesenteric/portal venous invasion in pancreatic cancer.

    PubMed

    Tewari, Mallika

    2016-12-01

    Pancreaticoduodenectomy with superior mesenteric/portal venous resection for pancreatic ductal adenocarcinoma (PDAC) is frequently performed with no added morbidity or mortality in case of tumor abutment to the superior mesenteric or portal vein so as to obtain a margin negative resection. True histopathological portal vein invasion is found only in a small subset of such patients. The aim of this review aimed to discuss the significance of histopathological venous invasion in PDAC. For this review available data was searched from PubMed and analyzed. No randomized trials have been published on this topic. Existing data on prognostic factors in histopathological venous invasion by PDAC are limited and recent studies indicate worse survival in this subgroup of patients. In addition, venous invasion in PDAC has been associated with large tumors, involved lymph nodes, perineural invasion and R1 resection. The survival of patients with portal venous resection but without histologic venous invasion is reportedly better than those with histopathological venous invasion; though conflicting studies do exist on the subject. Some studies also relate the depth of venous invasion to prognosis after surgical resection of PDAC. Frank/'histopathological' invasion of superior mesenteric/portal venous and R1 resection indicate a very poor survival. Such patients may be given the opportunity of benefit of neoadjuvant treatment.

  6. Simultaneous Increases in Proliferation and Apoptosis of Vascular Smooth Muscle Cells Accelerate Diabetic Mouse Venous Atherosclerosis

    PubMed Central

    Liu, Shuying; Zhang, Zhengyu; Wang, Jingjing; Zhou, Yuhuan; Liu, Kefeng; Huang, Jintao; Chen, Dadi; Wang, Junmei; Li, Chaohong

    2015-01-01

    Aims This study was designed to demonstrate simultaneous increases in proliferation and apoptosis of vascular smooth muscle cells (VSMCs) leading to accelerated vein graft remodeling and to explore the underlying mechanisms. Methods Vein grafts were performed in non-diabetic and diabetic mice. The cultured quiescent VSMCs were subjected to mechanical stretch stress (SS) and/or advanced glycosylation end products (AGEs). Harvested vein grafts and treated VSMCs were used to detect cell proliferation, apoptosis, mitogen-activated protein kinases (MAPKs) activation and SM-α-actin expression. Results Significantly thicker vessel walls and greater increases in proliferation and apoptosis were observed in diabetic vein grafts than those in non-diabetic. Both SS and AGEs were found to induce different activation of three members of MAPKs and simultaneous increases in proliferation and apoptosis of VSMCs, and combined treatment with both had a synergistic effect. VSMCs with strong SM-α-actin expression represented more activated JNKs or p38MAPK, and cell apoptosis, while the cells with weak SM-α-actin expression demonstrated preferential activation of ERKs and cell proliferation. In contrast, inhibition of MAPKs signals triggered significant decreases in VSMC proliferation, and apoptosis. Treatment of the cells with RNA interference of receptor of AGEs (RAGE) also resulted in significant decreases in both proliferation and apoptosis. Conclusions Increased pressure-induced SS triggers simultaneous increases in proliferation and apoptosis of VSMCs in the vein grafts leading to vein arterializations, which can be synergistically accelerated by high glucose-induced AGEs resulting in vein graft atherosclerosis. Either SS or AGEs and their combination induce simultaneous increases in proliferation and apoptosis of VSMCs via different activation of three members of MAPKs resulting from different VSMC subtypes classified by SM-α-actin expression levels. PMID:26488175

  7. Validation of Risk Assessment Models of Venous Thromboembolism in Hospitalized Medical Patients.

    PubMed

    Greene, M Todd; Spyropoulos, Alex C; Chopra, Vineet; Grant, Paul J; Kaatz, Scott; Bernstein, Steven J; Flanders, Scott A

    2016-09-01

    Patients hospitalized for acute medical illness are at increased risk for venous thromboembolism. Although risk assessment is recommended and several at-admission risk assessment models have been developed, these have not been adequately derived or externally validated. Therefore, an optimal approach to evaluate venous thromboembolism risk in medical patients is not known. We conducted an external validation study of existing venous thromboembolism risk assessment models using data collected on 63,548 hospitalized medical patients as part of the Michigan Hospital Medicine Safety (HMS) Consortium. For each patient, cumulative venous thromboembolism risk scores and risk categories were calculated. Cox regression models were used to quantify the association between venous thromboembolism events and assigned risk categories. Model discrimination was assessed using Harrell's C-index. Venous thromboembolism incidence in hospitalized medical patients is low (1%). Although existing risk assessment models demonstrate good calibration (hazard ratios for "at-risk" range 2.97-3.59), model discrimination is generally poor for all risk assessment models (C-index range 0.58-0.64). The performance of several existing risk assessment models for predicting venous thromboembolism among acutely ill, hospitalized medical patients at admission is limited. Given the low venous thromboembolism incidence in this nonsurgical patient population, careful consideration of how best to utilize existing venous thromboembolism risk assessment models is necessary, and further development and validation of novel venous thromboembolism risk assessment models for this patient population may be warranted. Published by Elsevier Inc.

  8. Potential involvement of the extracranial venous system in central nervous system disorders and aging

    PubMed Central

    2013-01-01

    Background The role of the extracranial venous system in the pathology of central nervous system (CNS) disorders and aging is largely unknown. It is acknowledged that the development of the venous system is subject to many variations and that these variations do not necessarily represent pathological findings. The idea has been changing with regards to the extracranial venous system. Discussion A range of extracranial venous abnormalities have recently been reported, which could be classified as structural/morphological, hemodynamic/functional and those determined only by the composite criteria and use of multimodal imaging. The presence of these abnormalities usually disrupts normal blood flow and is associated with the development of prominent collateral circulation. The etiology of these abnormalities may be related to embryologic developmental arrest, aging or other comorbidities. Several CNS disorders have been linked to the presence and severity of jugular venous reflux. Another composite criteria-based vascular condition named chronic cerebrospinal venous insufficiency (CCSVI) was recently introduced. CCSVI is characterized by abnormalities of the main extracranial cerebrospinal venous outflow routes that may interfere with normal venous outflow. Summary Additional research is needed to better define the role of the extracranial venous system in relation to CNS disorders and aging. The use of endovascular treatment for the correction of these extracranial venous abnormalities should be discouraged, until potential benefit is demonstrated in properly-designed, blinded, randomized and controlled clinical trials. Please see related editorial: http://www.biomedcentral.com/1741-7015/11/259. PMID:24344742

  9. [Methods for reducing dacarbazine photodegradation and its accompanying venous pain].

    PubMed

    Tsuji, Takumi; Ohtsubo, Tatsuya; Umeyama, Takayo; Sudou, Miho; Komesu, Kana; Matsumoto, Minako; Yoshida, Yuya; Banno, Rie; Mikami, Tadashi; Kohno, Takeyuki

    2014-01-01

    The anticancer drug dacarbazine (DTIC) is photosensitive, and the photodegradation product 5-diazoimidazole-4-carboxamide (diazo-IC) induces adverse reactions including local venous pain during intravenous injection. In this study we evaluated the effectiveness of colored shields (orange and red) to protect against photodegradation of DTIC as determined by ascertaining the concentration of diazo-IC. Samples were prepared and stored under four conditions: (1) no shield; (2) covered with an aluminum (opaque) shield; (3) covered with an orange shield; and (4) covered with a red shield. The samples were exposed to natural light for a specified time (0, 30, 60, 120, and 180 min) prior to measuring the concentration of diazo-IC by HPLC. We found that after 180 min, the diazo-IC concentration was 5.7±0.6 (S.D.) μg/mL with no shield and 1.9±0.2 μg/mL in both colored shield conditions. This production of diazo-IC under the colored shields was suppressed to a level similar to that under the aluminum shield (1.7±0.2 μg/mL). We also evaluated the effectiveness of NSAIDs (zaltoprofen, loxoprofen sodium, and diclofenac sodium) administered to mice prior to DTIC treatment on venous pain by counting their stretching and writhing reactions. Premedication with zaltoprofen significantly decreased expression of pain behavior in the DTIC-treated mice. These results suggest that storing DTIC under the protection of an orange or red shield is clinically beneficial because the shield prevents DTIC photodegradation, and that NSAIDs such as zaltoprofen are a promising premedication candidate for pain.

  10. The Effect of Diabetes and Hypertension on the Placental Permeation of the Hydrophilic Drug, Ranitidine.

    PubMed

    Lalic-Popovic, Mladena; Paunkovic, Jovana; Grujic, Zorica; Golocorbin-Kon, Svetlana; Vasovic, Velibor; Al-Salami, Hani; Mikov, Momir

    2016-12-01

    Ranitidine is a hydrophilic weak base and an H 2 -receptor antagonist which is commonly used for gastroesophageal reflux, including during pregnancy. It has limited placental permeation and can be used as a pre-anesthetic antacid to prevent aspiration of acidic stomach contents. Recent studies suggest that diabetes and hypertension may influence placental permeation of hydrophilic drugs. Thus, this study aimed to investigate the influence of diabetes and hypertension on ranitidine's placental permeation in pregnant women. Forty one pregnant women all scheduled for elective cesarean section entered the study: healthy control (n = 15), with hypertension (n = 16) and with gestational diabetes (n = 10). All women received 50 mg of ranitidine intravenously. Three samples of maternal plasma (after ranitidine application, at delivery and after delivery), and two umbilical cord samples (arterial and venous blood) were collected and analyzed for ranitidine concentrations. Maternal pharmacokinetic parameter were calculated as well as feto:maternal and umbilical cord arterial to venous concentration ratios. Ranitidine maternal and umbilical cord (arterial and venous) concentrations were similar in all three groups and there were no difference between feto:maternal ratios nor volume of distribution, clearance and half life between the groups. Fetal concentrations are dependent on maternal concentrations in healthy and hypertensive women but not in diabetic women. Hypertension and diabetes did not affect fetal handling of ranitidine. Though hypertension and diabetes did not influence ranitidine placental permeation, it appears they altered time needed to achieve unity between maternal and fetal plasma. Copyright © 2016. Published by Elsevier Ltd.

  11. Use of the retrograde limb of the internal mammary vein to avoid venous congestion in DIEP flap breast reconstruction: Further evidences of a reliable and time-sparing procedure.

    PubMed

    La Padula, Simone; Hersant, Barbara; Noel, Warren; Niddam, Jeremy; Hermeziu, Oana; Bouhassira, Jonathan; Bosc, Romain; Meningaud, Jean Paul

    2016-09-01

    Venous congestion is a common cause of DIEP flap failure. When identified intraoperatively, an additional venous anastomosis can improve the venous outflow and prevent flap failure. The aim of this study was to assess if the retrograde limb of the internal mammary vein (IMV) could be considered a good recipient vessel to be used when persistent flap congestion is present, and a second venous anastomosis is required. A retrospective study was conducted in 74 patients who had undergone DIEP flap breast reconstruction. Patients were classified into two groups: SVA (single venous anastomosis) and DVA (dual venous anastomosis). In the SVA group (n = 38), the IMV antegrade limb was used for venous drainage. A single DIEV (Deep Inferior Epigastric Vein) was anastomosed to the superior arm of the IMV. In the DVA group (n = 36), both the antegrade (superior) and retrograde (inferior) stumps of the IMV were used, connecting the larger DIEV to the antegrade IMV and the other DIEV or the SIEV (Superficial Inferior Epigastric Vein) to the IMV retrograde limb. No venous congestion or flap loss was observed when two venous anastomoses were performed using both the IMV antegrade and retrograde limbs (P = 0.3271). In the DVA group, no major complication occurred (P = 0.0453). Operative explorations were significantly reduced in the DVA group (P = 0.0242). These findings suggest that when an additional venous outflow is required, the use of the IMV retrograde limb may help to avoid flap venous congestion. © 2016 Wiley Periodicals, Inc. Microsurgery 36:447-452, 2016. © 2016 Wiley Periodicals, Inc.

  12. Manual lymphatic drainage in chronic venous disease: a duplex ultrasound study.

    PubMed

    Dos Santos Crisóstomo, Rute Sofia; Candeias, Miguel Sandu; Ribeiro, Ana Margarida Martins; da Luz Belo Martins, Catarina; Armada-da-Silva, Paulo As

    2014-12-01

    To compare the effect of call-up and reabsorption maneuvers of manual lymphatic drainage on blood flow in femoral vein and great saphenous vein in patients with chronic venous disease and healthy controls. Forty-one subjects participated in this study (mean age: 42.68(15.23)), 23 with chronic venous disease (chronic venous disease group) with clinical classification C1-5 of clinical-etiological-anatomical-pathological (CEAP) and 18 healthy subjects (control group). Call-up and reabsorption maneuvers were randomly applied in the medial aspect of the thigh. The cross-sectional areas, as well as the peak and the mean blood flow velocity at femoral vein and great saphenous vein, were assessed by Duplex ultrasound at the baseline and during maneuvers. The venous flow volume changes were calculated. The venous flow volume in femoral vein and great saphenous vein increased during both manual lymphatic drainage maneuvers and in both groups (P < 0.05). The two maneuvers had a similar effect on femoral vein and great saphenous vein hemodynamics, and in both the chronic venous disease and control groups. As a result of the call-up maneuver, the flow volume augmentations, as a result of call-up maneuver, decreased with the severity of chronic venous disease in those patients measured by the clinical classification of CEAP (r = -0.64; P = 0.03). Manual lymphatic drainage increases the venous blood flow in the lower extremity with a magnitude that is independent from the specific maneuver employed or the presence of chronic venous disease. Therefore, manual lymphatic drainage may be an alternative strategy for the treatment and prevention of venous stasis complications in chronic venous disease. © The Author(s) 2013 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  13. Central venous catheter-related thrombosis in senile male patients: New risk factors and predictors.

    PubMed

    Liu, Gao; Fu, Zhi-Qing; Zhu, Ping; Li, Shi-Jun

    2015-06-01

    Central venous catheterization (CVC)-related venous thrombosis is a common but serious clinical complication, thus prevention and treatment on this problem should be extensively investigated. In this research, we aimed to investigate the incidence rate of CVC-related venous thrombosis in senile patients and give a further discussion on the related risk factors and predictors. A total of 324 hospitalized senile male patients subjected to CVC were selected. Retrospective investigation and analysis were conducted on age, underlying diseases, clinical medications, catheterization position and side, catheter retention time, and incidence of CVC-related venous thrombosis complications. Basic laboratory test results during catheterization and thrombogenesis were also collected and analyzed. Among the 324 patients, 20 cases (6.17%) of CVC-related venous thrombosis were diagnoseds. The incidence rate of CVC-related venous thrombosis in subclavian vein catheterization was significantly lower than that in femoral vein catheterization (P<0.01) and that in internal jugular vein catheterization (P<0.05). No statistically significant difference was found between femoral vein catheterization and internal jugular vein catheterization (P<0.05). Previous venous thrombosis history (P<0.01), high lactate dehydrogenase level (P<0.01), low high-density lipoprotein (HDL) level (P<0.05), and low albumin level (P<0.05) were found as risk factors or predictors of CVC-related venous thrombosis in senile male patients. Subclavian vein catheterization was the most appropriate choice among senile patients to decrease the incidence of CVC-related venous thrombosis. Previous venous thrombosis history, high lactate dehydrogenase level, low HDL level, and low albumin level were important risk factors in predicting CVC-related venous thrombosis.

  14. Electronic Alerts, Comparative Practitioner Metrics, and Education Improves Thromboprophylaxis and Reduces Thrombosis.

    PubMed

    Woller, Scott C; Stevens, Scott M; Evans, R Scott; Wray, Daniel G; Christensen, John C; Aston, Valerie T; Wayne, Matthew H; Lloyd, James F; Wilson, Emily L; Elliott, C Gregory

    2016-10-01

    Venous thromboembolism chemoprophylaxis remains underutilized in hospitalized medical patients at high risk for venous thromboembolism. We assessed the effect of a health care quality-improvement initiative comprised of a targeted electronic alert, comparative practitioner metrics, and practitioner-specific continuing medical education on the rate of appropriate venous thromboembolism chemoprophylaxis provided to medical inpatients at high risk for venous thromboembolism. We performed a multicenter prospective observational cohort study in an urban Utah hospital system. All medical patients admitted to 1 of 2 participating hospitals from April 1, 2010 to December 31, 2012 were eligible. Patients were members of the "control" (April 1, 2010 to December 31, 2010), "intervention" (January 1, 2011 to December 31, 2011), or "subsequent year" (January 1, 2012 to December 31, 2012) group. The primary outcome was the rate of appropriate chemoprophylaxis among patients at high risk for venous thromboembolism. Secondary outcomes included rates of symptomatic venous thromboembolism, major bleeding, all-cause mortality, heparin-induced thrombocytopenia, physician satisfaction, and alert fatigue. The rate of appropriate chemoprophylaxis among patients at high risk for venous thromboembolism increased (66.1% control period vs 81.0% intervention period vs 88.1% subsequent year; P <.001 for each comparison). A significant reduction of 90-day symptomatic venous thromboembolism accompanied the quality initiative (9.3% control period, 9.7% intervention period, 6.7% subsequent year; P = .009); 30-day venous thromboembolism rates also significantly decreased. A multifaceted intervention was associated with increased appropriate venous thromboembolism chemoprophylaxis among medical inpatients at high risk for venous thromboembolism and reduced symptomatic venous thromboembolism. The effect of the intervention was sustained. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Ambulatory Status Protects against Venous Thromboembolism in Acute Mild Ischemic Stroke Patients.

    PubMed

    Sisante, Jason-Flor V; Abraham, Michael G; Phadnis, Milind A; Billinger, Sandra A; Mittal, Manoj K

    2016-10-01

    Ischemic stroke patients are at high risk (up to 18%) for venous thromboembolism. We conducted a retrospective cross-sectional study to understand the predictors of acute postmild ischemic stroke patient's ambulatory status and its relationship with venous thromboembolism, hospital length of stay, and in-hospital mortality. We identified 522 patients between February 2006 and May 2014 and collected data about patient demographics, admission NIHSS (National Institutes of Health Stroke Scale), venous thromboembolism prophylaxis, ambulatory status, diagnosis of venous thromboembolism, and hospital outcomes (length of stay, mortality). Chi-square test, t-test and Wilcoxon rank-sum test, and binary logistic regression were used for statistical analysis as appropriate. A total of 61 (11.7%), 48 (9.2%), and 23 (4.4%) mild ischemic stroke patients developed venous thromboembolism, deep venous thrombosis, and pulmonary embolism, respectively. During hospitalization, 281 (53.8%) patients were ambulatory. Independent predictors of in-hospital ambulation were being married (OR 1.64, 95% CI 1.10-2.49), being nonreligious (OR 2.19, 95% CI 1.34-3.62), admission NIHSS (per unit decrease in NIHSS; OR 1.62, 95% CI 1.39-1.91), and nonuse of mechanical venous thromboembolism prophylaxis (OR 1.62, 95% CI 1.02-2.61). After adjusting for confounders, ambulatory patients had lower rates of venous thromboembolism (OR .47, 95% CI .25-.89), deep venous thrombosis (OR .36, 95% CI .17-.73), prolonged length of hospital stay (OR .24, 95% CI .16-.37), and mortality (OR .43, 95% CI .21-.84). Our findings suggest that for hospitalized acute mild ischemic stroke patients, ambulatory status is an independent predictor of venous thromboembolism (specifically deep venous thrombosis), hospital length of stay, and in-hospital mortality. Copyright © 2016 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  16. Dot immunoassay for the simultaneous determination of postvaccination immunity against pertussis, diphtheria, and tetanus.

    PubMed

    Khramtsov, Pavel; Bochkova, Maria; Timganova, Valeria; Zamorina, Svetlana; Rayev, Mikhail

    2017-06-01

    A dot immunoassay for simultaneous semiquantitative detection of IgG against tetanus toxoid (Ttx) and diphtheria toxoid (Dtx) and qualitative detection of anti-Bordetella pertussis IgGs in human blood serum using carbon nanoparticles functionalized with streptococcal protein G was developed. Inactivated B. pertussis cells in suspension form were used as an antigen in the immunoassay. Pertussis, tetanus, and diphtheria antigens were separately spotted onto nitrocellulose strips, and then the immunostrips were successively incubated with blood sera and a suspension of carbon nanoparticles. The immunostrips were then scanned with a flatbed scanner, and the images obtained were processed with ImageJ. One hundred fifty-five venous blood serum samples from children vaccinated with diphtheria, tetanus, and whole-cell pertussis (DTwP) vaccine were tested in comparison with a conventional ELISA and agglutination test. The total time required for analysis of 32 serum samples was less than 3 h. Comparison between the results of the dot immunoassay and the corresponding ELISA/agglutination test revealed a high level of agreement (Cohen's kappa between 0.765 and 0.813). The lower limit of quantification was 0.06 IU/ml for anti-Ttx and anti-Dtx. The intra-assay coefficients of variation were less than 15% for anti-Ttx and anti-Dtx and less than 10% for anti-pertussis. The diagnostic sensitivity of detection of the antibody protection level was 93.5% for anti-Ttx [95% confidence interval (CI) 83.5-97.9%], 92.4% for anti-Dtx (95% CI 80.9297.5%), and 90.2% for anti-pertussis (95% CI 75.9-96.8%). The diagnostic specificity was 90.9% for anti-Ttx (95% CI 57.1-99.5%), 85% for anti-Dtx (95% CI 61.1-96.0%), and 89.3% for anti-pertussis (95%CI 80.8-94.5%). The dot immunoassay developed does not require expensive reading equipment, and allows detection of antibodies against three antigens in a single analysis. The immunostrips can be stored for a long time without changes in the coloration of the spots. Graphical Abstract The assay procedure. BC Bordetella pertussis cell suspension, CNP carbon nanoparticle, Dtx diphtheria toxoid, Ttx tetanus toxoid.

  17. The Toxicity of Inhaled Sulphur Mustard

    DTIC Science & Technology

    2012-03-01

    Pulse oximetry Mean arterial pressure Central venous pressure Blood Chemistry (arterial and venous ) pH pO2 pCO2 Sodium Potassium Calcium...Cardiovascular Parameters − CFI – Cardiac Function Index − CO – Cardiac Output − CvO2 – Mixed Venous Oxygenation − CVP – Central Venous Pressure...Data are expressed as mean ± SEM. Changes in central venous pressure following exposure to HD: HD controls () and HD + NAC (). Data are

  18. Detection of deep venous thrombophlebitis by gallium 67 scintigraphy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, J.H.

    1981-07-01

    Deep venous thrombophlebitis may escape clinical detection. Three cases are reported in which whole-body gallium 67 scintigraphy was used to detect unsuspected deep venous thrombophlebitis related to indwelling catheters in three children who were being evaluated for fevers of unknown origin. Two of these children had septicemia from Candida organisms secondary to these venous lines. Gallium 67 scintigraphy may be useful in the detection of complications of indwelling venous catheters.

  19. Detection of deep venous thrombophlebitis by Gallium 67 scintigraphy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, J.H.

    1981-07-01

    Deep venous thrombophlebitis may escape clinical detection. Three cases are reported in which whole-body gallium 67 scintigraphy was used to detect unsuspected deep venous thrombophlebitis related to indwelling catheters in three children who were being evaluated for fevers of unknown origin. Two of these children had septicemia from Candida organisms secondary to these venous lines. Gallium 67 scintigraphy may be useful in the detection of complications of indwelling venous catheters.

  20. Influence of diazepam on blood glucose levels in nondiabetic and non-insulin-dependent diabetic subjects under dental treatment with local anesthesia.

    PubMed Central

    Schaira, Vanessa Rocha Lima; Ranali, José; Saad, Mário José Abdalla; de Oliveira, Patrícia Cristine; Ambrosano, Glaúcia Maria Bovi; Volpato, Maria Cristina

    2004-01-01

    The effect of diazepam on blood glucose concentration (BGC) was investigated in a double-blind cross-over study in 10 healthy and 10 non-insulin-dependent diabetic subjects taking oral hypoglycemic drugs. In the first session, fasting blood samples were taken for blood glucose and glycosylated hemoglobin estimation and at 60, 80, 95, 125, and 155 minutes thereafter for glucose estimation. In another 2 sessions, a venous sample was taken immediately before premedication (5 mg diazepam or placebo randomly given during breakfast). One hour later a blood sample was taken, and the volunteers were submitted to periodontal treatment after injection of 1.8 mL of 2% mepivacaine with 1:100,000 adrenaline. Venous blood samples were taken at 15, 30, 60, and 90 minutes after injection. The changes in BGC were analyzed using analysis of variance (ANOVA) for repeated measures; the means were compared using Tukey test (P = .05). Statistically significant differences in the BGC were observed between diabetic and nondiabetic groups (P = .00003). However, there were no significant differences among the sessions of the same group (P = .29). The results of this study show that a single dose of 5 mg diazepam before dental treatment does not influence BGC in nondiabetic and non-insulin-dependent diabetic subjects. PMID:15106685

  1. Caregiver Education Reduces the Incidence of Community-Acquired CLABSIs in the Pediatric Patient With Intestinal Failure.

    PubMed

    Drews, Barbie; Macaluso, Michelle; Piper, Hannah; Channabasappa, Nandini

    Pediatric patients with intestinal failure often require central venous catheters for extended periods of time for parenteral nutrition, blood sampling, and medication administration, increasing morbidity, mortality, and costs. In 2007, we reported a central line-associated bloodstream infection rate of 7.0 per 1,000 catheter line-days in our pediatric patients with intestinal failure. On the basis of this high rate of catheter-associated infections, we developed and implemented a central line care curriculum for patients/family caregivers and home health nurses. We aim to show with the implementation of patient/family caregiver and home health nurse standardized education, the central line-associated bloodstream infection rate can be significantly reduced and that this is sustainable. A retrospective review of 80 pediatric outpatients with intestinal failure and long-term central venous access was performed between January 1, 2009, and December 31, 2014. During this time period, the nursing department at Children's Medical Center of Dallas implemented a systematic central line care education program for patients and/or caregivers. The number of community-acquired central line-associated bloodstream infections during this time period was collected and compared with our previously reported data from 2005 to 2007 prior to the implementation of education program. With the implementation of standardized care guidelines and a central venous catheter care curriculum, the community-acquired rate decreased from 4.8 to 2.9 per 1,000 catheter-days in 80 patients with intestinal failure between January 1, 2009, and December 31, 2014 (p < .001). This was also a significant decrease compared with the initial central line-associated bloodstream infection rate of 7.0 per 1,000 central line days in 2007 (p < .001) prior to the development of the central venous catheter care curriculum. We have shown that the incidence of community-acquired central line-associated bloodstream infections in children with intestinal failure can be reduced through formal education of central venous catheter care to family members.

  2. The Indian Council of Medical Research–India Diabetes (ICMR–INDIAB) Study: Methodological Details

    PubMed Central

    Anjana, Ranjit Mohan; Pradeepa, Rajendra; Deepa, Mohan; Datta, Manjula; Sudha, Vasudevan; Unnikrishnan, Ranjit; Nath, Lalith M; Das, Ashok Kumar; Madhu, Sri Venkata; Rao, Paturi Vishnupriya; Shukla, Deepak Kumar; Kaur, Tanvir; Ali, Mohammed K; Mohan, Viswanathan

    2011-01-01

    Background Currently available estimates of diabetes prevalence in India are based on published data derived from very few studies. The Indian Council of Medical Research–India Diabetes (ICMR–INDIAB) study is a community-based survey conceived with the aim of obtaining the prevalence rates of diabetes in India as a whole, covering all 28 states, the National Capital Territory of Delhi, and two of the union territories in the mainland of India, with a total sample size of 124,000 individuals. Methods A stratified multistage sampling design has been used. In all study subjects, a structured questionnaire was administered and anthropometric parameters and blood pressure were measured. Fasting capillary blood glucose was first determined using a glucose meter. An oral glucose load was then administered to all subjects except those with self-reported diabetes, and the 2 h post-load capillary blood glucose was estimated. In every fifth subject, a fasting venous sample was collected for measurement of lipids and creatinine, a resting 12-lead electrocardiogram was performed, and dietary assessment questionnaire was administered. In all diabetic subjects, an additional diabetes questionnaire was used and a fasting venous sample drawn for glycated hemoglobin. Results All biological samples collected were analyzed in a central laboratory. All data collected were stored electronically. Quality control was achieved through multiple tiers of checks. Conclusions The ICMR–INDIAB study is the first of its kind attempting to provide accurate and comprehensive state- and national-level data on diabetes prevalence in India. PMID:21880233

  3. Cardiac veins: collateral venous drainage pathways in chronic hemodialysis patients.

    PubMed

    Ozmen, Evrim; Algin, Oktay

    2016-07-12

    Venous anomalies are diagnostic and therapeutic challenges. Subclavian or superior vena cava stenosis can be developed and venous return can be achieved via cardiac veins and coronary sinus in patients with central venous catheter for long-term hemodialysis. These types of abnormalities are not extremely rare especially in patients with a history of central venous catheter placement. Detection of these anomalies and subclavian vein stenosis before the surgical creation of hemodialysis fistulae or tunneled central venous catheter placement may prevent unnecessary interventions in those patients. Multidetector computed tomography (MDCT) technique can give further information when compared with fluoroscopy or digital subtraction angiography in the management of these patients. This case report describes interesting aspects of central vein complications in hemodialysis patients. As a conclusion, there are limited data about thoracic venous return, and further prospective studies with large patient number are required. MDCT with 3D reconstruction is particularly useful for the accurate evaluation of venous patency, variations, and collateral circulation. Also it is an excellent tool for choosing and planning treatment.

  4. A small amount can make a difference: a prospective human study of the paradoxical coagulation characteristics of hemothorax.

    PubMed

    Smith, W Zachary; Harrison, Hannah B; Salhanick, Marc A; Higgins, Russell A; Ortiz, Alfonso; Olson, John D; Schwacha, Martin G; Harrison, Chantal R; Aydelotte, Jayson D; Stewart, Ronald M; Dent, Daniel L

    2013-12-01

    The evacuated hemothorax has been poorly described because it varies with time, it has been found to be incoagulable, and its potential effect on the coagulation cascade during autotransfusion is largely unknown. This is a prospective descriptive study of adult patients with traumatic chest injury necessitating tube thoracostomy. Pleural and venous samples were analyzed for coagulation, hematology, and electrolytes at 1 to 4 hours after drainage. Pleural samples were also analyzed for their effect on the coagulation cascade via mixing studies. Thirty-four subjects were enrolled with a traumatic hemothorax. The following measured coagulation factors were significantly depleted compared with venous blood: international normalized ratio (>9 vs 1.1) (P < .001) and activated partial thromboplastin time (aPTT) (>180 vs 24.5 seconds) (P < .001). Mixing studies showed a dose-dependent increase in coagulation dilutions through 1:8 (P < .05). An evacuated hemothorax does not vary in composition significantly with time and is incoagulable alone. Mixing studies with hemothorax plasma increased coagulation, raising safety concerns. Copyright © 2013 Elsevier Inc. All rights reserved.

  5. Comparison of pre-filter and post-filter ionised calcium monitoring in continuous veno-venous hemodiafiltration (CVVHD-F) with citrate anti-coagulation.

    PubMed

    Brain, Matthew J; Roodenburg, Owen S; McNeil, John

    2017-01-01

    It is widespread practice during citrate anticoagulated renal replacement therapy to monitor circuit ionised calcium (iCa2+) to evaluate the effectiveness of anticoagulation. Whether the optimal site to sample the blood path is before or after the haemofilter is a common question. Using a prospectively collected observational dataset from intensive care patients receiving pre-dilution continuous veno-venous haemodiafiltration (CVVHD-F) with integrated citrate anticoagulation we compared paired samples of pre and post filter iCa2+ where the target range was 0.3-0.5 mmol.L-1 as well as concurrently collected arterial iCa2+. Two nested mixed methods linear models were fitted to the data describing post vs pre filter iCa2+, and the relationship of pre, post and arterial samples. An 11 bed general intensive care unit. 450 grouped samples from 152 time periods in seven patients on CRRT with citrate anticoagulation. The relationship of post to pre-filter iCa2+ was not 1:1 with post = 0.082 + 0.751 x pre-filter iCa2+ (95% CI intercept: 0.015-0.152, slope 0.558-0.942). Variation was greatest between patients rather than between circuits within the same patient or citrate dose. Compared to arterial iCa2+ there was no significant difference between pre and post-filter sampling sites (F-value 0.047, p = 0.827). These results demonstrate that there is minimal difference between pre and post filter samples for iCa2+ monitoring of circuit anticoagulation in citrate patients relative to the arterial iCa2+ in CVVHD-F however compared to pre-filter sampling, post filter sampling has a flatter response and greater variation.

  6. Comparison of pre-filter and post-filter ionised calcium monitoring in continuous veno-venous hemodiafiltration (CVVHD-F) with citrate anti-coagulation

    PubMed Central

    Roodenburg, Owen S.; McNeil, John

    2017-01-01

    Background It is widespread practice during citrate anticoagulated renal replacement therapy to monitor circuit ionised calcium (iCa2+) to evaluate the effectiveness of anticoagulation. Whether the optimal site to sample the blood path is before or after the haemofilter is a common question. Methods Using a prospectively collected observational dataset from intensive care patients receiving pre-dilution continuous veno-venous haemodiafiltration (CVVHD-F) with integrated citrate anticoagulation we compared paired samples of pre and post filter iCa2+ where the target range was 0.3–0.5 mmol.L-1 as well as concurrently collected arterial iCa2+. Two nested mixed methods linear models were fitted to the data describing post vs pre filter iCa2+, and the relationship of pre, post and arterial samples. Setting An 11 bed general intensive care unit. Participants 450 grouped samples from 152 time periods in seven patients on CRRT with citrate anticoagulation. Results The relationship of post to pre-filter iCa2+ was not 1:1 with post = 0.082 + 0.751 x pre-filter iCa2+ (95% CI intercept: 0.015–0.152, slope 0.558–0.942). Variation was greatest between patients rather than between circuits within the same patient or citrate dose. Compared to arterial iCa2+ there was no significant difference between pre and post-filter sampling sites (F-value 0.047, p = 0.827) Conclusion These results demonstrate that there is minimal difference between pre and post filter samples for iCa2+ monitoring of circuit anticoagulation in citrate patients relative to the arterial iCa2+ in CVVHD-F however compared to pre-filter sampling, post filter sampling has a flatter response and greater variation. PMID:29272278

  7. Rivaroxaban attenuates thrombosis by targeting the NF-κB signaling pathway in a rat model of deep venous thrombus

    PubMed Central

    Ma, Junhao; Li, Xinxi; Wang, Yang; Yang, Zhenwei; Luo, Jun

    2017-01-01

    Anticoagulant therapy is commonly used for the prevention and treatment of patients with deep venous thrombus. Evidence has shown that rivaroxaban is a potential oral anticoagulant drug for the acute treatment of venous thromboembolism. However, the rivaroxaban-mediated molecular mechanism involved in the progression of deep venous thrombosis has not been investigated. In the present study, we investigated the efficacy of rivaroxaban and the underlying signaling pathways in the prevention and treatment of rats with deep venous thrombosis. A rat model with deep vein thrombus formation was established and received treatment with rivaroxaban or PBS as control. The thrombin-activatable fibrinolysis inhibitor (TAFI) and plasminogen activator inhibitor-1 (PAI-1) were analyzed both in vitro and in vivo. The progression of thrombosis and stroke was evaluated after treatment with rivaroxaban or PBS. Nuclear factor-κB (NF-κB) signaling pathway in venous endothelial cells and in the rat model of deep venous thrombus was assessed. The therapeutic effects of rivaroxaban were evaluated as determined by changes in deep venous thrombosis in the rat model. Our results showed that rivaroxaban markedly inhibited TAFI and PAI-1 expression levels, neutrophils, tissue factor, neutrophil extracellular traps (NETs), myeloperoxidase and macrophages in venous endothelial cells and in the rat model of deep venous thrombus. Expression levels of ADP, PAIs, von Willebrand factor (vWF) and thromboxane were downregulated in vein endothelial cells and in serum from the experimental rats. Importantly, the incidences of inferior vena cava filter thrombus were protected by rivaroxaban during heparin-induced thrombolysis deep venous thrombosis in the rat model. We observed that activity of the NF-κB signaling pathway was inhibited by rivaroxaban in vein endothelial cells both in vitro and in vivo. Notably, immunohistology indicated that rivaroxaban attenuated deep venous thrombosis and the accumulation of inflammatory factors in the lesions in venous thrombus. Matrix metalloproteinase (MMP) expression and activity were downregulated in rivaroxaban-treated rats with deep venous thrombus. Rivaroxaban inhibited the elasticity of the extracellular matrix and collagen-elastin fibers. On the whole, these results indicate that rivaroxaban attenuates deep venous thrombus through MMP-9-mediated NF-κB signaling pathway. PMID:29039441

  8. Rivaroxaban attenuates thrombosis by targeting the NF-κB signaling pathway in a rat model of deep venous thrombus.

    PubMed

    Ma, Junhao; Li, Xinxi; Wang, Yang; Yang, Zhenwei; Luo, Jun

    2017-12-01

    Anticoagulant therapy is commonly used for the prevention and treatment of patients with deep venous thrombus. Evidence has shown that rivaroxaban is a potential oral anticoagulant drug for the acute treatment of venous thromboembolism. However, the rivaroxaban-mediated molecular mechanism involved in the progression of deep venous thrombosis has not been investigated. In the present study, we investigated the efficacy of rivaroxaban and the underlying signaling pathways in the prevention and treatment of rats with deep venous thrombosis. A rat model with deep vein thrombus formation was established and received treatment with rivaroxaban or PBS as control. The thrombin-activatable fibrinolysis inhibitor (TAFI) and plasminogen activator inhibitor-1 (PAI-1) were analyzed both in vitro and in vivo. The progression of thrombosis and stroke was evaluated after treatment with rivaroxaban or PBS. Nuclear factor-κB (NF-κB) signaling pathway in venous endothelial cells and in the rat model of deep venous thrombus was assessed. The therapeutic effects of rivaroxaban were evaluated as determined by changes in deep venous thrombosis in the rat model. Our results showed that rivaroxaban markedly inhibited TAFI and PAI-1 expression levels, neutrophils, tissue factor, neutrophil extracellular traps (NETs), myeloperoxidase and macrophages in venous endothelial cells and in the rat model of deep venous thrombus. Expression levels of ADP, PAIs, von Willebrand factor (vWF) and thromboxane were downregulated in vein endothelial cells and in serum from the experimental rats. Importantly, the incidences of inferior vena cava filter thrombus were protected by rivaroxaban during heparin-induced thrombolysis deep venous thrombosis in the rat model. We observed that activity of the NF-κB signaling pathway was inhibited by rivaroxaban in vein endothelial cells both in vitro and in vivo. Notably, immunohistology indicated that rivaroxaban attenuated deep venous thrombosis and the accumulation of inflammatory factors in the lesions in venous thrombus. Matrix metalloproteinase (MMP) expression and activity were downregulated in rivaroxaban-treated rats with deep venous thrombus. Rivaroxaban inhibited the elasticity of the extracellular matrix and collagen-elastin fibers. On the whole, these results indicate that rivaroxaban attenuates deep venous thrombus through MMP-9-mediated NF-κB signaling pathway.

  9. Nursing Theory, Terminology, and Big Data: Data-Driven Discovery of Novel Patterns in Archival Randomized Clinical Trial Data.

    PubMed

    Monsen, Karen A; Kelechi, Teresa J; McRae, Marion E; Mathiason, Michelle A; Martin, Karen S

    The growth and diversification of nursing theory, nursing terminology, and nursing data enable a convergence of theory- and data-driven discovery in the era of big data research. Existing datasets can be viewed through theoretical and terminology perspectives using visualization techniques in order to reveal new patterns and generate hypotheses. The Omaha System is a standardized terminology and metamodel that makes explicit the theoretical perspective of the nursing discipline and enables terminology-theory testing research. The purpose of this paper is to illustrate the approach by exploring a large research dataset consisting of 95 variables (demographics, temperature measures, anthropometrics, and standardized instruments measuring quality of life and self-efficacy) from a theory-based perspective using the Omaha System. Aims were to (a) examine the Omaha System dataset to understand the sample at baseline relative to Omaha System problem terms and outcome measures, (b) examine relationships within the normalized Omaha System dataset at baseline in predicting adherence, and (c) examine relationships within the normalized Omaha System dataset at baseline in predicting incident venous ulcer. Variables from a randomized clinical trial of a cryotherapy intervention for the prevention of venous ulcers were mapped onto Omaha System terms and measures to derive a theoretical framework for the terminology-theory testing study. The original dataset was recoded using the mapping to create an Omaha System dataset, which was then examined using visualization to generate hypotheses. The hypotheses were tested using standard inferential statistics. Logistic regression was used to predict adherence and incident venous ulcer. Findings revealed novel patterns in the psychosocial characteristics of the sample that were discovered to be drivers of both adherence (Mental health Behavior: OR = 1.28, 95% CI [1.02, 1.60]; AUC = .56) and incident venous ulcer (Mental health Behavior: OR = 0.65, 95% CI [0.45, 0.93]; Neuro-musculo-skeletal function Status: OR = 0.69, 95% CI [0.47, 1.00]; male: OR = 3.08, 95% CI [1.15, 8.24]; not married: OR = 2.70, 95% CI [1.00, 7.26]; AUC = .76). The Omaha System was employed as ontology, nursing theory, and terminology to bridge data and theory and may be considered a data-driven theorizing methodology. Novel findings suggest a relationship between psychosocial factors and incident venous ulcer outcomes. There is potential to employ this method in further research, which is needed to generate and test hypotheses from other datasets to extend scientific investigations from existing data.

  10. Percutaneous transfemoral repositioning of malpositioned central venous catheters.

    PubMed

    Hartnell, G G; Roizental, M

    1995-04-01

    Central venous catheters inserted by blind surgical placement may not advance into a satisfactory position and may require repositioning. Malpositioning via surgical insertion is common in patients in whom central venous catheters have previously been placed, as these patients are more likely to have central venous thrombosis and distortion of central venous anatomy. This is less of a problem when catheter placement is guided by imaging; however, even when insertion is satisfactory, central venous catheters may become displaced spontaneously after insertion (Fig. 1). Repositioning can be effected by direct manipulation using guidewires or tip-deflecting wires [1, 2], by manipulation via a transfemoral venous approach [3-5], and by injection of contrast material or saline [6]. Limitations of the direct approach include (1) the number and type of maneuvers that can be performed to effect repositioning when anatomy is distorted, (2) difficulty in accessing the catheter, and (3) the risk of introducing infection. Moreover, these patients are often immunosuppressed, and there is a risk of introducing infection by exposing and directly manipulating the venous catheter. Vigorous injection of contrast material or saline may be unsuccessful for the same reasons: It seldom exerts sufficient force to reposition large-caliber central venous catheters and may cause vessel damage or rupture if injection is made into a small or thrombosed vessel. We illustrate several alternative methods for catheter repositioning via a transfemoral venous approach.

  11. The Diagnostic Value of 3-Dimensional Sampling Perfection With Application Optimized Contrasts Using Different Flip Angle Evolutions (SPACE) MRI in Evaluating Lower Extremity Deep Venous Thrombus.

    PubMed

    Wu, Gang; Xie, Ruyi; Zhang, Xiaoli; Morelli, John; Yan, Xu; Zhu, Xiaolei; Li, Xiaoming

    2017-12-01

    The aim of this study was to evaluate the diagnostic performance of noncontrast magnetic resonance imaging utilizing sampling perfection with application optimized contrasts using different flip angle evolutions (SPACE) in detecting deep venous thrombus (DVT) of the lower extremity and evaluating clot burden. This prospective study was approved by the institutional review board. Ninety-four consecutive patients (42 men, 52 women; age range, 14-87 years; average age, 52.7 years) suspected of lower extremity DVT underwent ultrasound (US) and SPACE. The venous visualization score for SPACE was determined by 2 radiologists independently according to a 4-point scale (1-4, poor to excellent). The sensitivity and specificity of SPACE in detecting DVT were calculated based on segment, limb, and patient, with US serving as the reference standard. The clot burden for each segment was scored (0-3, patent to entire segment occlusion). The clot burden score obtained with SPACE was compared with US using a Wilcoxon test based on region, limb, and patient. Interobserver agreement in assessing DVT (absent, nonocclusive, or occlusive) with SPACE was determined by calculating Cohen kappa coefficients. The mean venous visualization score for SPACE was 3.82 ± 0.50 for reader 1 and 3.81 ± 0.50 for reader 2. For reader 1, sensitivity/specificity values of SPACE in detecting DVT were 96.53%/99.90% (segment), 95.24%/99.04% (limb), and 95.89%/95.24% (patient). For reader 2, corresponding values were 97.20%/99.90%, 96.39%/99.05%, and 97.22%/95.45%. The clot burden assessed with SPACE was not significantly different from US (P > 0.05 for region, limb, patient). Interobserver agreement of SPACE in assessing thrombosis was excellent (kappa = 0.894 ± 0.014). Non-contrast-enhanced 3-dimensional SPACE magnetic resonance imaging is highly accurate in detecting lower extremity DVT and reliable in the evaluation of clot burden. SPACE could serve as an important alternative for patients in whom US cannot be performed.

  12. Use of peripherally inserted central venous catheters (PICCs) in children receiving autologous or allogeneic stem-cell transplantation.

    PubMed

    Benvenuti, Stefano; Ceresoli, Rosanna; Boroni, Giovanni; Parolini, Filippo; Porta, Fulvio; Alberti, Daniele

    2018-03-01

    The aim of our study was to present our experience with the use of peripherally inserted central catheters (PICCs) in pediatric patients receiving autologous or allogenic blood stem-cell transplantation. The insertion of the device in older children does not require general anesthesia and does not require a surgical procedure. From January 2014 to January 2017, 13 PICCs were inserted as a central venous device in 11 pediatric patients submitted to 14 autologous or allogeneic stem-cell transplantation, at the Bone Marrow Transplant Unit of the Children's Hospital of Brescia. The mean age of patients at the time of the procedure was 11.3 years (range 3-18 years). PICCs remained in place for an overall period of 4104 days. All PICCs were positioned by the same specifically trained physician and utilized by nurses of our stem-cell transplant unit. No insertion-related complications were observed. Late complications were catheter ruptures and line occlusions (1.2 per 1000 PICC days). No rupture or occlusion required removal of the device. No catheter-related venous thrombosis, catheter-related bloodstream infection (CRBSI), accidental removal or permanent lumen occlusion were observed. Indications for catheter removal were completion of therapy (8 patients) and death (2 patients). Three PICCs are currently being used for blood sampling in follow-up patients after transplantation. Our data suggest that PICCs are a safe and effective alternative to conventional central venous catheters even in pediatric patients with high risk of infectious and hemorrhagic complications such as patients receiving stem-cell transplantation.

  13. Central venous catheter-related infections in patients receiving short-term hemodialysis therapy: incidence, associated factors, and microbiological aspects.

    PubMed

    Menegueti, Mayra Gonçalves; Betoni, Natália Cristina; Bellissimo-Rodrigues, Fernando; Romão, Elen Almeida

    2017-01-01

    Bloodstream infections are the second most common cause of death among patients on hemodialysis. This study aimed to evaluate the incidence of and risk factors associated with central venous catheter-related infections in patients undergoing hemodialysis, and to identify and characterize the type and antimicrobial susceptibility profiles of the primary microorganisms isolated during one year of follow-up. A prospective cohort study was conducted in 2014 in a hemodialysis referral center. We included 200 outpatients with acute kidney injury who had no permanent venous access. A nurse assessed the patients for signs of infection three times per week during dressing changes. The clinicopathologic characteristics of patients with and without local or systemic infection were compared. Fifty-five episodes of catheter-related infections occurred in 43 (22%) patients; 38 (69%) were bloodstream infections and 17 (31%) were local infections. Thirty-two (75%) patients with infection had femoral vein catheter placement. In total, 6,240 hemodialysis sessions were performed; the rates of primary bloodstream and local infection were 6.1 and 2.7 episodes per 1,000 patients on daily dialysis, respectively. In the univariate analysis, diabetes was significantly associated with the development of infection, while level of education, ethnicity, age, and sex were not. Gram-negative bacteria were primarily isolated from blood culture specimens (55% of samples). Of the Gram-negative isolates, 56% were resistant to the carbapenems. We identified a high incidence of catheter-related infections caused by resistant microorganisms in patients undergoing hemodialysis via central venous catheters.

  14. Serial alterations in digital hemodynamics and endothelin-1 immunoreactivity, platelet-neutrophil aggregation, and concentrations of nitric oxide, insulin, and glucose in blood obtained from horses following carbohydrate overload.

    PubMed

    Eades, Susan C; Stokes, Ashley M; Johnson, Philip J; LeBlanc, Casey J; Ganjam, Venkataseshu K; Buff, Preston R; Moore, Rustin M

    2007-01-01

    To quantify changes in endothelium-derived factors and relate those changes to various aspects of digital hemodynamics during the prodromal stages of carbohydrate overload (CHO)-induced laminitis in horses. 20 adult horses without abnormalities of the digit. Digital and jugular venous blood samples were collected at 1-hour intervals (for assessment of endothelin-1 [ET-1] immunoreactivity and measurement of glucose, insulin, and nitric oxide [NO] concentrations) or 4-hour intervals (CBC and platelet-neutrophil aggregate assessment) for 8 hours or 16 hours after induction of CHO-associated laminitis in horses treated with an ET-1 antagonist. Effects of treatment, collection site, and time and the random effects of horse on each variable were analyzed by use of a repeated-measures model. Where treatment and collection site had no significant effect, data were combined. Compared with baseline values, CHO resulted in changes in several variables, including a significant increase from baseline in digital blood ET-like immunoreactivity at 11 hours; digital blood ET-like immunoreactivity was significantly greater than that in jugular venous blood at 8, 9, 11, and 12 hours. Digital and jugular venous blood concentrations of glucose increased from baseline significantly at 3, 4, and 5 hours; insulin concentration increased significantly at 5 hours; and the number of platelet-neutrophil aggregates increased significantly at 12 hours. In horses, concurrent increases in venous blood ET-1 immunoreactivity, insulin and glucose concentrations, and platelet-neutrophil aggregates support a role of endothelial dysfunction in the pathogenesis of CHO-induced laminitis.

  15. Variations in magnetic resonance venographic anatomy of the dorsal dural venous sinus system in 51 dogs.

    PubMed

    Fenn, Joe; Lam, Richard; Kenny, Patrick J

    2013-01-01

    Variations in intracranial dural venous sinus anatomy have been widely reported in humans, but there have been no studies reporting this in dogs. The purpose of this retrospective study was to describe variations in magnetic resonance (MR) venographic anatomy of the dorsal dural venous sinus system in a sample population of dogs with structurally normal brains. Medical records were searched for dogs with complete phase contrast, intracranial MR venograms and a diagnosis of idiopathic epilepsy. Magnetic resonance venograms were retrieved for each dog and characteristics of the dorsal dural sinuses, symmetry of the transverse sinuses and other anatomic variations were recorded. A total of 51 dogs were included. Transverse sinus asymmetry was present in 58.8% of the dogs, with transverse sinus hypoplasia seen in 39.2%, and aplasia in 23.5% of dogs. For 70.6% of dogs, at least one anatomic variation in the dorsal sagittal sinus was observed, including deviation from the midline (33.3%) and collateral branches from either the dorsal sagittal sinus or dorsal cerebral veins (54.9%). In 5 dogs (9.8%) a vessel was also identified running from the proximal transverse sinus to the distal sigmoid sinus, in a similar location to the occipital sinus previously reported in children. Findings from this study indicated that, as in humans, anatomic variations are common in the intracranial dural venous sinus system of dogs. These anatomic variations should be taken into consideration for surgical planning or diagnosis of cerebrovascular disease. © 2013 Veterinary Radiology & Ultrasound.

  16. Evaluation of the monitor cursor-line method for measuring pulmonary artery and central venous pressures.

    PubMed

    Pasion, Editha; Good, Levell; Tizon, Jisebelle; Krieger, Staci; O'Kier, Catherine; Taylor, Nicole; Johnson, Jennifer; Horton, Carrie M; Peterson, Mary

    2010-11-01

    To determine if the monitor cursor-line feature on bedside monitors is accurate for measuring central venous and pulmonary artery pressures in cardiac surgery patients. Central venous and pulmonary artery pressures were measured via 3 methods (end-expiratory graphic recording, monitor cursor-line display, and monitor digital display) in a convenience sample of postoperative cardiac surgery patients. Pressures were measured twice during both mechanical ventilation and spontaneous breathing. Analysis of variance was used to determine differences between measurement methods and the percentage of monitor pressures that differed by 4 mm Hg or more from the measurement obtained from the graphic recording. Significance level was set at P less than .05. Twenty-five patients were studied during mechanical ventilation (50 measurements) and 21 patients during spontaneous breathing (42 measurements). Measurements obtained via the 3 methods did not differ significantly for either type of pressure (P > .05). Graphically recorded pressures and measurements obtained via the monitor cursor-line or digital display methods differed by 4 mm Hg or more in 4% and 6% of measurements, respectively, during mechanical ventilation and 4% and 11%, respectively, during spontaneous breathing. The monitor cursor-line method for measuring central venous and pulmonary artery pressures may be a reasonable alternative to the end-expiratory graphic recording method in hemodynamically stable, postoperative cardiac surgery patients. Use of the digital display on the bedside monitor may result in larger discrepancies from the graphically recorded pressures than when the cursor-line method is used, particularly in spontaneously breathing patients.

  17. Autologous platelet-rich plasma in the treatment of venous leg ulcers in primary care: a randomised controlled, pilot study.

    PubMed

    Burgos-Alonso, Natalia; Lobato, Igone; Hernández, Igone; Sebastian, Kepa San; Rodríguez, Begoña; March, Anna Giné; Perez-Salvador, Adriana; Arce, Veronica; Garcia-Alvarez, Arturo; Gomez-Fernandez, Maria Cruz; Grandes, Gonzalo; Andia, Isabel

    2018-06-01

    To examine the potential efficacy and safety of autologous platelet-rich plasma (PRP) in comparison with the conventional treatment (standard care, SoC) for the treatment of leg ulcers in patients with chronic venous insufficiency, in a primary health-care setting. A Phase I-II, open-label, parallel-group, multicentre, randomised pilot study was conducted. The outcome variables at baseline and at weeks five and nine included reduction in the ulcer area, Chronic Venous Insufficiency Quality of Life Questionnaire score, cost of the treatment for up to nine weeks and average weekly cure rate. A total of eight patients, each with at least a six-month history of venous leg ulcer (VLUs), were included in the study. A total of 12 ulcers were treated with either autologous PRP or standard SoC. Patients treated with PRP required wound care only once per week. In the SoC group, patients required intervention 2-3 times per week. A reduction in the mean ulcer size in the PRP group was 3.9cm 2 compared with the SoC group at 3.2cm 2 , although the sample size was insufficient to reach statistical significance. Improvement in quality of life (QoL) score was observed in the patients in the PRP group. This study offers proof-of-concept of the feasibility and safety of PRP treatment to inform larger clinical trials in patients with VLUs. Our preliminary results suggest that PRP delivers a safe and effective treatment for VLU care that can be implemented in primary health-care settings.

  18. Adrenal hormones before and after venography during adrenal venous sampling: a self-controlled study.

    PubMed

    Koike, Yuya; Matsui, Seishi; Omura, Masao; Makita, Kohzoh; Obara, Alfonso W D; Moriya, Nobukazu; Nishikawa, Tetsuo

    2017-03-01

    A stress reaction involving increased adrenal hormone release occurs when starting adrenal venous sampling (AVS). The purpose of the present study was to investigate the effect of single shot venography on adrenal hormone production during AVS. This was a prospective self-controlled study. We enrolled 54 consecutive patients (21 men, 33 women; mean age 52 ± 11 years) with primary aldosteronism who underwent AVS from May 2014 to February 2015. Under non-stimulated conditions, blood samples were obtained from a common trunk of the left adrenal vein before and after single shot venography. The initial plasma aldosterone and cortisol concentration (PAC and PCC) were compared with those measured after venography for each patient. PAC and PCC were slightly but significantly decreased between before and after venography (after log transformation 2.12 ± 0.73 vs 2.07 ± 0.72, P = 0.00066, 1.89 ± 0.52 vs 1.83 ± 0.53, P = 0.00031, respectively). During non-stimulated left AVS, adrenal hormone secretion was slightly but significantly decreased after venography, similar to the normal time-related stress reaction. Venography did not increase the adrenal hormone secretion.

  19. Non-stimulated adrenal venous sampling using Dyna computed tomography in patients with primary aldosteronism

    PubMed Central

    Chang, Chin-Chen; Lee, Bo-Ching; Liu, Kao-Lang; Chang, Yeun-Chung; Wu, Vin-Cent; Huang, Kuo-How

    2016-01-01

    In this retrospective study, we aimed to examine the effect of applying Dyna computed tomography (CT) on the success rate of adrenal venous sampling (AVS) without adrenocorticotropic hormone stimulation. A total of 100 consecutive patients with primary aldosteronism who underwent AVS between May 2012 and July 2015 were enrolled. In all the cases, Dyna CT was used in AVS to validate catheter position in the right adrenal vein. A selectivity index (cortisoladrenal vein /cortisolinferior vena cava) of ≥2.0 of both adrenal veins were required for successful AVS. Dyna CT indicated misplaced catheters in 16 patients; of these patients, 75% (12/16) eventually had successful right AVS after catheter repositioning. The success rate of initial sampling at the right adrenal vein was 76% (76/100), which increased to 88% (88/100) after Dyna CT was applied (p < 0.001). The most common inadvertently catheterised vessels detected using Dyna CT were the accessory hepatic veins (56.3%, 9/16), followed by the renal capsular veins (37.5%, 6/16). The overall success rate of non-stimulated AVS using Dyna CT was 87% (87/100). Thus, the application of Dyna CT further increased the success rate of non-stimulated AVS. PMID:27876824

  20. [The behavior of arterial and mixed venous oxygen and carbon dioxide partial pressure and the pH value during and following intubation apnoea. Studies on the occurrence of the Christiansen-Douglas-Haldane effect].

    PubMed

    Merkelbach, D; Brandt, L; Mertzlufft, F

    1993-10-01

    The Christiansen-Douglas-Haldane effect describes the reduced CO2 binding capacity of oxygenated compared to deoxygenated haemoglobin. Under the condition of a "closed system", for example hyperoxic apnoea after adequate preoxygenation (continuous O2 uptake with lack of CO2 delivery), specific effects on the arterial and mixed venous blood gas status, due to the Haldane effect, are seen: within 30 s after onset of apnoea, "paradoxical pCO2" (paCO2 exceeds pvCO2) and "pH reversal" (pHa falls under pHv) can be observed. It was the aim of this study to demonstrate how fast arterial and mixed venous pCO2 and pH normalize when a change from apnoea ("closed system") to controlled ventilation ("open system") takes place. METHODS. 12 patients (ASA II-IV, NYHA II-III) scheduled for coronary artery bypass grafting were studied. Premedication consisted of flunitrazepam 2.0 mg p.o. given the evening before operation and another 2.0 mg p.o. given 90-120 min before induction of anaesthesia. Routine preparation for induction consisted of venous and arterial cannulas, pulmonary artery catheter and continuous pulse oximetry. Following standardized preoxygenation, induction of anaesthesia was performed with fentanyl, pancuronium and etomidate. After cessation of spontaneous respiration, controlled ventilation was continued with 100% O2 until intubation. Intubation and insertion of stomach tube and oesophageal temperature probe were undertaken after exactly 2 min. After reconnection to the semi-closed circle breathing system, controlled ventilation was continued with 100% O2. Eighteen arterial (a) and 18 mixed-venous (v) blood samples were drawn simultaneously in a sequential manner immediately before and during the last 20 s of apnoea, as well as within 4 min after onset of controlled ventilation (Table 1). The pO2 (mmHg), pCO2 (mmHg) and pH were determined using a Stat Profile 5 blood gas analyser. RESULTS. During apnoea and within the first 35 s of controlled ventilation the paO2 showed a total decrease of 131.5 mmHg that was followed by an almost linear increase of 29.7 mmHg/min (Fig. 1a). In the course of apnoea and controlled ventilation the pvO2 remained relatively stable, with values ranging from 42 to 43 mmHg (Fig. 1b). During apnoea the paCO2 showed an increase of 12.5 mmHg that was followed by a biphasic decrease (first 13.8 mmHg/min and then 0.75 mmHg/min) beginning 15 s after the onset of controlled ventilation (Fig. 2a). With an increase of 4.2 mmHg, the pvCO2 showed about a third of the increase of the paCO2 during apnoea, reaching a maximum 45 s after the onset of controlled ventilation and then being followed by a linear decrease of 0.86 mmHg/min (Fig.2b). Comparing the course of paCO2 and pvCO2 during apnoea as well as during the period of controlled ventilation, pHa and pHv changed in a reciprocal manner (Fig. 3a/b). The so-called normalization of pCO2 (paCO2 falls under pvCO2) and pH (pHa exceeds pHv) began 18.2 s and 23.2 s respectively after the onset of controlled ventilation (Fig. 4a, b). CONCLUSION. Considering the expected decrease of paO2 during hyperoxic apnoea, insufficient pulmonary N2 elimination prior to the onset of apnoea, as well as direct N2 delivery into the alveoli, due to the so-called a ventilatory mass flow, will limit unrestricted pulmonary O2 uptake. The continuing decrease of the paCO2 after the onset of controlled ventilation can be regarded as indirect proof of a ventilatory mass flow. The course of pCO2 and pH after the onset of controlled ventilation shows that normalization in arterial and mixed-venous blood gas status takes place in about 18.2 s after the cessation of apnoea.

  1. Right atrial pressure: determinant or result of change in venous return?

    PubMed

    Bendjelid, Karim

    2005-11-01

    According to the concept of Guyton, cardiac output is largely controlled by venous return, which is determined by the difference between mean systemic venous pressure and right atrial pressure. In the analysis of the venous return curve, other authors have suggested that right atrial pressure is the dependent variable and venous return is the independent variable (right atrial pressure decreased because cardiac output increased). The present report analyzes this historical debate, which has already lasted > 50 years.

  2. Role of interventional radiologists in the management of lower extremity venous insufficiency.

    PubMed

    Hardman, Rulon L; Rochon, Paul J

    2013-12-01

    Lower extremity venous insufficiency affects over half of all women. Interventional radiologists should be aware of the clinical evaluation of women with venous insufficiency and classification of disease. Endovascular therapies available for treatment of lower extremity venous insufficiency include: endovenous laser ablation, radiofrequency endovascular ablation, and sclerotherapy. The interventional radiologist should be versed on which therapy to select in each clinical presentation and the procedural techniques. The authors review the role of the interventional radiologist in managing this lower extremity venous disorder.

  3. Multimodal noninvasive and invasive imaging of extracranial venous abnormalities indicative of CCSVI: Results of the PREMiSe pilot study

    PubMed Central

    2013-01-01

    Background There is no established noninvasive or invasive diagnostic imaging modality at present that can serve as a ‘gold standard’ or “benchmark” for the detection of the venous anomalies, indicative of chronic cerebrospinal venous insufficiency (CCSVI). We investigated the sensitivity and specificity of 2 invasive vs. 2 noninvasive imaging techniques for the detection of extracranial venous anomalies in the internal jugular veins (IJVs) and azygos vein/vertebral veins (VVs) in patients with multiple sclerosis (MS). Methods The data for this multimodal imaging comparison pilot study was collected in phase 2 of the “Prospective Randomized Endovascular therapy in Multiple Sclerosis” (PREMiSe) study using standardized imaging techniques. Thirty MS subjects were screened initially with Doppler sonography (DS), out of which 10 did not fulfill noninvasive screening procedure requirements on DS that consisted of ≥2 venous hemodynamic extracranial criteria. Accordingly, 20 MS patients with relapsing MS were enrolled into the multimodal diagnostic imaging study. For magnetic resonance venography (MRV), IJVs abnormal findings were considered absent or pinpoint flow, whereas abnormal VVs flow was classified as absent. Abnormalities of the VVs were determined only using non-invasive testing. Catheter venography (CV) was considered abnormal when ≥50% lumen restriction was detected, while intravascular ultrasound (IVUS) was considered abnormal when ≥50% restriction of the lumen or intra-luminal defects or reduced pulsatility was found. Non-invasive and invasive imaging modality comparisons between left, right and total IJVs and between the VVs and azygos vein were performed. Because there is no reliable way of non-invasively assessing the azygos vein, the VVs abnormalities detected by the non-invasive testing were compared to the azygos abnormalities detected by the invasive testing. All image modalities were analyzed in a blinded manner by more than one viewer, upon which consensus was reached. The sensitivity and specificity were calculated using contingency tables denoting the presence or absence of vein-specific abnormality findings between all imaging modalities used individually as the benchmark. Results The sensitivity of CV + IVUS was 68.4% for the right and 90% for the left IJV and 85.7% for the azygos vein/VVs, compared to venous anomalies detected on DS. Compared to the venous anomalies detected on MRV, the sensitivity of CV + IVUS was 71.4% in right and 100% in left IJVs and 100% in the azygos vein/VVs; however, the specificity was 38.5%, 38.9% and 11.8%, respectively. The sensitivity between the two invasive imaging techniques, used as benchmarks, ranged from 72.7% for the right IJV to 90% for the azygos vein but the IVUS showed a higher rate of venous anomalies than the CV. There was excellent correspondence between identifying collateral veins on MRV and CV. Conclusions Noninvasive DS screening for the detection of venous anomalies indicative of CCSVI may be a reliable approach for identifying patients eligible for further multimodal invasive imaging testing of the IJVs. However, the noninvasive screening methods were inadequate to depict the total amount of azygos vein/VVs anomalies identified with invasive testing. This pilot study, with limited sample size, shows that both a non-invasive and invasive multimodal imaging diagnostic approach should be recommended to depict a range of extracranial venous anomalies indicative of CCSVI. However, lack of invasive testing on the study subjects whose results were negative on the DS screening and of healthy controls, limits further generalizibility of our findings. In addition, the findings from the 2 invasive techniques confirmed the existence of severe extracranial venous anomalies that significantly impaired normal blood outflow from the brain in this group of MS patients. PMID:24139135

  4. Thrombophlebitis

    MedlinePlus

    ... thrombophlebitis. Alternative Names Phlebitis; Deep vein thrombosis - thrombophlebitis Images Deep venous thrombosis, iliofemoral Venous blood clot References Ginsberg JS. Peripheral venous disease. In: Goldman L, Schafer AI, ...

  5. Femoral vein injury managed by in situ saphenous vein bypass : a case report.

    PubMed

    Coppin, Th; Kuhnle, M

    2014-01-01

    Injured veins of the lower limbs may cause massive haemorrhage requiring early control. Operative management of injured veins remains a controversial topic and reconstruction or ligation depends on venous and adjacent tissue damage. Nevertheless, venous reconstruction seems to reduce the complications of venous ligation. The case of a 33 year old women with a venous wound to the right groin is presented. Surgical management consisted of controlling the bleeding and venous revascularisation with an in situ saphenous vein bypass to substitute the injured femoral vein. The patient had an uneventful postoperative period without any complications. The case demonstrates this method of vascular venous repair is the preferable one. Copyright© Acta Chirurgica Belgica.

  6. Core content for training in venous and lymphatic medicine.

    PubMed

    Zimmet, Steven E; Min, Robert J; Comerota, Anthony J; Meissner, Mark H; Carman, Teresa L; Rathbun, Suman W; Jaff, Michael R; Wakefield, Thomas W; Feied, Craig F

    2014-10-01

    The major venous societies in the United States share a common mission to improve the standards of medical practitioners, the educational goals for teaching and training programs in venous disease, and the quality of patient care related to the treatment of venous disorders. With these important goals in mind, a task force made up of experts from the specialties of dermatology, interventional radiology, phlebology, vascular medicine, and vascular surgery was formed to develop a consensus document describing the Core Content for venous and lymphatic medicine and to develop a core educational content outline for training. This outline describes the areas of knowledge considered essential for practice in the field, which encompasses the study, diagnosis, and treatment of patients with acute and chronic venous and lymphatic disorders. The American Venous Forum and the American College of Phlebology have endorsed the Core Content. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  7. Duplex investigations in children: Are clinical signs in children with venous disorders relevant?

    PubMed

    Birgitte Maessen-Visch, M; Smeets, L; van Vleuten, C

    2015-12-01

    Ultra sound colored duplex sonography is the preferred method in diagnosing chronic venous disease. Data in children on incidence, indications, and results are lacking. From the total of 9180 duplex investigations performed in our hospital from 2009 to 2012, data on indication and results of the investigation as well as patient characteristics were evaluated retrospectively for the proportion of pediatric patients. Duplex investigations were performed 49 times in 38 children (6-18 years), with an average of 1.3 times (1-6 times) per child. Forty percent showed abnormalities: 17 times deep venous thrombosis was suspected; deep venous thrombosis was objectified in 18%. In the 21 investigations performed for varicosis-related complaints, varicose veins or venous malformations were objectified in 57%. Edema was never a symptom of chronic venous disease. Duplex investigation is not often performed in children. In children with established deep venous thrombosis, a family history with deep venous thrombosis is common. In general, edema was not seen in children with varicose veins and, therefore, does not seem a reliable clinical sign at young age. © The Author(s) 2014.

  8. Performance of the RAD-57 pulse CO-oximeter compared with standard laboratory carboxyhemoglobin measurement.

    PubMed

    Touger, Michael; Birnbaum, Adrienne; Wang, Jessica; Chou, Katherine; Pearson, Darion; Bijur, Polly

    2010-10-01

    We assess agreement between carboxyhemoglobin levels measured by the Rad-57 signal extraction pulse CO-oximeter (RAD), a Food and Drug Administration-approved device for noninvasive bedside measurement, and standard laboratory arterial or venous measurement in a sample of emergency department (ED) patients with suspected carbon monoxide poisoning. The study was a cross-sectional cohort design using a convenience sample of adult and pediatric ED patients in a Level I trauma, burn, and hyperbaric oxygen referral center. Measurement of RAD carboxyhemoglobin was performed simultaneously with blood sampling for laboratory determination of carboxyhemoglobin level. The difference between the measures for each patient was calculated as laboratory carboxyhemoglobin minus carboxyhemoglobin from the carbon monoxide oximeter. The limits of agreement from a Bland-Altman analysis are calculated as the mean of the differences between methods ±1.96 SDs above and below the mean. Median laboratory percentage carboxyhemoglobin level was 2.3% (interquartile range 1 to 8.5; range 0% to 38%). The mean difference between laboratory carboxyhemoglobin values and RAD values was 1.4% carboxyhemoglobin (95% confidence interval [CI] 0.2% to 2.6%). The limits of agreement of differences of measurement made with the 2 devices were -11.6% and 14.4% carboxyhemoglobin. This range exceeded the value of ±5% carboxyhemoglobin defined a priori as clinically acceptable. RAD correctly identified 11 of 23 patients with laboratory values greater than 15% carboxyhemoglobin (sensitivity 48%; 95% CI 27% to 69%). There was one case of a laboratory carboxyhemoglobin level less than 15%, in which the RAD device gave a result greater than 15% (specificity of RAD 96/97=99%; 95% CI 94% to 100%). In the range of carboxyhemoglobin values measured in this sample, the level of agreement observed suggests RAD measurement may not be used interchangeably with standard laboratory measurement. Copyright © 2010 American College of Emergency Physicians. Published by Mosby, Inc. All rights reserved.

  9. [Risk Factors for Oxaliplatin-Induced Phlebitis and Venous Pain, and Evaluation of the Preventive Effect of Preheating with a Hot Compress for Administration of Oxaliplatin].

    PubMed

    Nakauchi, Kana; Kawazoe, Hitoshi; Miyajima, Risa; Waizumi, Chieko; Rokkaku, Yuki; Tsuneoka, Kikue; Higuchi, Noriko; Fujiwara, Mitsuko; Kojima, Yoh; Yakushijin, Yoshihiro

    2015-11-01

    Venous pain induced by oxaliplatin(L-OHP)is a clinical issue related to adherence to the Cape OX regimen. To prevent LOHP- induced venous pain, we provided nursing care to outpatients who were administered a preheated L -OHP diluted solution using a hot compress. We retrospectively evaluated the risk factors for colorectal cancer patients who had L -OHP induced phlebitis and venous pain. Furthermore, the preventive effect of nursing care was compared between inpatients and outpatients from January 2010 to March 2012. At the L-OHP administration site, any symptoms were defined as phlebitis, whereas pain was defined as venous pain. A total of 132 treatment courses among 31 patients were evaluated. Multivariate logistic regression analysis revealed that both phlebitis and venous pain were significantly more common in female patients (adjusted odds ratio, 2.357; 95%CI: 1.053-5.418; and adjusted odds ratio, 5.754; 95%CI: 2.119-18.567, respectively). The prevalence of phlebitis and venous pain did not differ between inpatients and outpatients (phlebitis, 61.3% vs 67.7%; venous pain, 29.0%vs 19.4%). These results suggest that administration of L-OHP via a central venous route should be considered in female patients.

  10. Elevated plasma factor VIII enhances venous thrombus formation in rabbits: contribution of factor XI, von Willebrand factor and tissue factor.

    PubMed

    Sugita, Chihiro; Yamashita, Atsushi; Matsuura, Yunosuke; Iwakiri, Takashi; Okuyama, Nozomi; Matsuda, Shuntaro; Matsumoto, Tomoko; Inoue, Osamu; Harada, Aya; Kitazawa, Takehisa; Hattori, Kunihiro; Shima, Midori; Asada, Yujiro

    2013-07-01

    Elevated plasma levels of factor VIII (FVIII) are associated with increased risk of deep venous thrombosis. The aim of this study is to elucidate how elevated FVIII levels affect venous thrombus formation and propagation in vivo. We examined rabbit plasma FVIII activity, plasma thrombin generation, whole blood coagulation, platelet aggregation and venous wall thrombogenicity before and one hour after an intravenous infusion of recombinant human FVIII (rFVIII). Venous thrombus induced by the endothelial denudation of rabbit jugular veins was histologically assessed. Thrombus propagation was evaluated as indocyanine green fluorescence intensity. Argatroban, a thrombin inhibitor, and neutralised antibodies for tissue factor (TF), factor XI (FXI), and von Willebrand factor (VWF) were infused before or after thrombus induction to investigate their effects on venous thrombus formation or propagation. Recombinant FVIII (100 IU/kg) increased rabbit plasma FVIII activity two-fold and significantly enhanced whole blood coagulation and total plasma thrombin generation, but did not affect initial thrombin generation time, platelet aggregation and venous wall thrombogenicity. The rFVIII infusion also increased the size of venous thrombus 1 hour after thrombus induction. Argatroban and the antibodies for TF, FXI or VWF inhibited such enhanced thrombus formation and all except TF suppressed thrombus propagation. In conclusion, elevated plasma FVIII levels enhance venous thrombus formation and propagation. Excess thrombin generation by FXI and VWF-mediated FVIII recruitment appear to contribute to the growth of FVIII-driven venous thrombus.

  11. Cortical venous disease severity in MELAS syndrome correlates with brain lesion development.

    PubMed

    Whitehead, M T; Wien, M; Lee, B; Bass, N; Gropman, A

    2017-08-01

    MELAS syndrome is a mitochondrial disorder typified by recurrent stroke-like episodes, seizures, and progressive brain injury. Abnormal mitochondria have been found in arterial walls implicating a vasculogenic etiology. We have observed abnormal cortical vein T2/FLAIR signal in MELAS patients, potentially representing wall thickening and sluggish flow. We sought to examine the relationship of hyperintense veins and brain lesions in MELAS. Imaging databases at two children's hospitals were searched for brain MRIs from MELAS patients. Artifact, sedated exams, and lack of 2D-T2/FLAIR sequences were exclusion criteria. Each exam was assigned a venous score based on number of T2/FLAIR hyperintense veins: 1 = <10, 2 = 10 to 20, 3 = >20. Cumulative brain lesions and venous score in MELAS and aged-matched normal exams were compared by Mann-Whitney test. A total of 106 exams from 14 unique MELAS patients (mean 16 ± 3 years) and 30 exams from normal aged-matched patients (mean 15 ± 3 years) were evaluated. Median venous score between MELAS and control patients significantly differed (3 versus 1; p < 0.001). In the MELAS group, venous score correlated with presence (median = 3) or absence (median = 1) of cumulative brain lesions. In all 8 MELAS patients who developed lesions, venous hyperintensity was present prior to, during, and after lesion onset. Venous score did not correlate with brain lesion acuity. Abnormal venous signal correlates with cumulative brain lesion severity in MELAS syndrome. Cortical venous stenosis, congestion, and venous ischemia may be mechanisms of brain injury. Identification of cortical venous pathology may aid in diagnosis and could be predictive of lesion development.

  12. Prevalence of difficult venous access and associated risk factors in highly complex hospitalised patients.

    PubMed

    Armenteros-Yeguas, Victoria; Gárate-Echenique, Lucía; Tomás-López, Maria Aranzazu; Cristóbal-Domínguez, Estíbaliz; Moreno-de Gusmão, Breno; Miranda-Serrano, Erika; Moraza-Dulanto, Maria Inmaculada

    2017-12-01

    To estimate the prevalence of difficult venous access in complex patients with multimorbidity and to identify associated risk factors. In highly complex patients, factors like ageing, the need for frequent use of irritant medication and multiple venous catheterisations to complete treatment could contribute to exhaustion of venous access. A cross-sectional study was conducted. 'Highly complex' patients (n = 135) were recruited from March 2013-November 2013. The main study variable was the prevalence of difficult venous access, assessed using one of the following criteria: (1) a history of difficulties obtaining venous access based on more than two attempts to insert an intravenous line and (2) no visible or palpable veins. Other factors potentially associated with the risk of difficult access were also measured (age, gender and chronic illnesses). Univariate analysis was performed for each potential risk factor. Factors with p < 0·2 were then included in multivariable logistic regression analysis. Odds ratios were also calculated. The prevalence of difficult venous access was 59·3%. The univariate logistic regression analysis indicated that gender, a history of vascular access complications and osteoarticular disease were significantly associated with difficult venous access. The multivariable logistic regression showed that only gender was an independent risk factor and the odds ratios was 2·85. The prevalence of difficult venous access is high in this population. Gender (female) is the only independent risk factor associated with this. Previous history of several attempts at catheter insertion is an important criterion in the assessment of difficult venous access. The prevalence of difficult venous access in complex patients is 59·3%. Significant risk factors include being female and a history of complications related to vascular access. © 2017 John Wiley & Sons Ltd.

  13. Risk factors associated with the occurrence of silent pulmonary embolism in patients with deep venous thrombosis of the lower limb.

    PubMed

    Li, Fenghe; Wang, Xuehu; Huang, Wen; Ren, Wei; Cheng, Jun; Zhang, Mao; Zhao, Yu

    2014-08-01

    The aim of our study is to investigate the prevalence of silent pulmonary embolism in patients with deep venous thrombosis in the lower limbs and to evaluate the associated risk factors. A total of 322 patients with acute deep venous thrombosis confirmed by CT venography or Doppler ultrasonography were studied. The diagnosis of silent pulmonary embolism was established by computed tomography pulmonary arteriography (CTPA). The association between covariates and the prevalence of silent pulmonary embolism in patients with deep venous thrombosis in lower limbs were assessed using chi-square test and multivariable regression. The incidence of silent pulmonary embolism was 33.5% (108 in 322 patients) in all patients with deep venous thrombosis in lower limbs. Chi-square test showed male gender, the right lower limb, proximal location of the thrombus, unprovoked venous thrombosis and coexisting heart diseases were related to a higher incidence of silent pulmonary embolism in patients with deep venous thrombosis in lower limbs. The multivariate regression analysis confirmed that the risk factors associated with silent pulmonary embolism in deep venous thrombosis patients included the right side and proximal location of the thrombus (odds ratio: 2.023, 95% CI: 1.215-3.368; odds ratio: 3.610, 95% CI: 1.772-7.354), unprovoked venous thrombosis (odds ratio: 2.037, 95% CI: 1.188-3.493), coexisting heart diseases (odds ratio: 4.507, 95% CI: 2.667-7.618). Silent pulmonary embolism occurred frequently in patients with deep venous thrombosis in lower limbs. The right side, the proximal location of the thrombus, unprovoked venous thrombosis and coexisting heart diseases increased the risk for the occurrence of silent pulmonary embolism. © The Author(s) 2013 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  14. Molecular identification of venous progenitors in the dorsal aorta reveals an aortic origin for the cardinal vein in mammals

    PubMed Central

    Lindskog, Henrik; Kim, Yung Hae; Jelin, Eric B.; Kong, Yupeng; Guevara-Gallardo, Salvador; Kim, Tyson N.; Wang, Rong A.

    2014-01-01

    Coordinated arterial-venous differentiation is crucial for vascular development and function. The origin of the cardinal vein (CV) in mammals is unknown, while conflicting theories have been reported in chick and zebrafish. Here, we provide the first molecular characterization of endothelial cells (ECs) expressing venous molecular markers, or venous-fated ECs, within the emergent dorsal aorta (DA). These ECs, expressing the venous molecular markers Coup-TFII and EphB4, cohabited the early DA with ECs expressing the arterial molecular markers ephrin B2, Notch and connexin 40. These mixed ECs in the early DA expressed either the arterial or venous molecular marker, but rarely both. Subsequently, the DA exhibited uniform arterial markers. Real-time imaging of mouse embryos revealed EC movement from the DA to the CV during the stage when venous-fated ECs occupied the DA. We analyzed mutants for EphB4, which encodes a receptor tyrosine kinase for the ephrin B2 ligand, as we hypothesized that ephrin B2/EphB4 signaling may mediate the repulsion of venous-fated ECs from the DA to the CV. Using an EC quantification approach, we discovered that venous-fated ECs increased in the DA and decreased in the CV in the mutants, whereas the rest of the ECs in each vessel were unaffected. This result suggests that the venous-fated ECs were retained in the DA and missing in the CV in the EphB4 mutant, and thus that ephrin B2/EphB4 signaling normally functions to clear venous-fated ECs from the DA to the CV by cell repulsion. Therefore, our cellular and molecular evidence suggests that the DA harbors venous progenitors that move to participate in CV formation, and that ephrin B2/EphB4 signaling regulates this aortic contribution to the mammalian CV. PMID:24550118

  15. A mobile compression device for thrombosis prevention in hip and knee arthroplasty.

    PubMed

    Colwell, Clifford W; Froimson, Mark I; Anseth, Scott D; Giori, Nicholas J; Hamilton, William G; Barrack, Robert L; Buehler, Knute C; Mont, Michael A; Padgett, Douglas E; Pulido, Pamela A; Barnes, C Lowery

    2014-02-05

    Venous thromboembolic events, either deep venous thrombosis or pulmonary embolism, are important complications in patients undergoing knee or hip arthroplasty. The purpose of this study was to evaluate the effectiveness of a mobile compression device (ActiveCare+S.F.T.) with or without aspirin compared with current pharmacological protocols for prophylaxis against venous thromboembolism in patients undergoing elective primary unilateral arthroplasty of a lower-extremity joint. A multicenter registry was established to capture the rate of symptomatic venous thromboembolic events following primary knee arthroplasty (1551 patients) or hip arthroplasty (1509 patients) from ten sites. All patients were eighteen years of age or older with no known history of venous thromboembolism, coagulation disorder, or solid tumor. Use of the compression device began perioperatively and continued for a minimum of ten days. Patients with symptoms of deep venous thrombosis or pulmonary embolism underwent duplex ultrasonography and/or spiral computed tomography. All patients were evaluated at three months postoperatively to document any evidence of deep venous thrombosis or pulmonary embolism. Of 3060 patients, twenty-eight (0.92%) had venous thromboembolism (twenty distal deep venous thrombi, three proximal deep venous thrombi, and five pulmonary emboli). One death occurred, with no autopsy performed. Symptomatic venous thromboembolic rates observed in patients who had an arthroplasty of a lower-extremity joint using the mobile compression device were noninferior (not worse than), at a margin of 1.0%, to the rates reported for pharmacological prophylaxis, including warfarin, enoxaparin, rivaroxaban, and dabigatran, except in the knee arthroplasty group, in which the mobile compression device fell short of the rate reported for rivaroxaban by 0.06%. Use of the mobile compression device with or without aspirin for patients undergoing arthroplasty of a lower-extremity joint provides a noninferior risk for the development of venous thromboembolism compared with current pharmacological protocols.

  16. A survey of the European Venous Forum on education and training in venous surgery and phlebology in Europe.

    PubMed

    Spanos, K; De Maeseneer, M; Nicolaides, A; Giannoukas, A D

    2015-04-01

    Venous training in Europe is lacking a formal curriculum among various specialties related to management of venous diseases. We conducted a survey in order to have a snapshot on the actual education and training level among physicians practicing currently venous surgery and phlebology in Europe. From April 7, 2014 to June 11, 2014 a survey was carried out using the Survey Monkey system, including 11 main questions covering all the domains of training and education in venous surgery and phlebology. The questionnaire was sent to all physicians included in the current mailing list of the European Venous Forum (EVF) and the Mediterranean League of Angiology and Vascular Surgery. Two questions were particularly addressed to those physicians who had attended the EVF hands-on workshop (HOW) at least once. The response rate was 24% (97/400) and 51.5% of them were practicing in a hospital service. Most responders were vascular surgeons (67.7%), followed by angiologists (19.4%). Only half of the responders felt as being competent to manage the whole spectrum of venous diseases successfully after completion of their training, while a few were able to perform endovenous ablations and even less more advanced venous interventions. Formal training in Duplex ultrasound was undertaken only in 55.2%. The majority suggested that a venous training program should be a separate part of their specialty rotation and should be organized at a national or European level, or even by a specific scientific society. Over 95% of those physicians who already participated in the EVF HOW considered the knowledge they acquired there as useful for their practice. There is currently an important need for more specialized venous training for all physicians involved in the diagnosis and management of venous diseases. Therefore all local, national and international initiatives should be encouraged to improve education in this field.

  17. Ambulatory Status Protects Against Venous Thromboembolism in Acute Mild Ischemic Stroke Patients

    PubMed Central

    Sisante, Jason-Flor V.; Abraham, Michael G.; Phadnis, Milind A.; Billinger, Sandra A.; Mittal, Manoj K.

    2016-01-01

    Introduction Ischemic stroke patients are at high risk (up to 18%) for venous thromboembolism. We conducted a retrospective cross-sectional study to understand the predictors of acute post-mild ischemic stroke patient’s ambulatory status and its relationship with venous thromboembolism, hospital length of stay, and in-hospital mortality. Methods We identified 522 patients between February 2006 and May 2014 and collected data about patient demographics, admission NIHSS, venous thromboembolism prophylaxis, ambulatory status, diagnosis of venous thromboembolism, and hospital outcomes (length of stay, mortality). Chi-square tests, t-test and Wilcoxon Ranks Sum tests, and binary logistic regression were used for statistical analysis as appropriate. Results A total of 61 (11.7%), 48 (9.2%), and 23 (4.4%) mild ischemic stroke patients developed venous thromboembolism, deep venous thrombosis, and pulmonary embolism, respectively. During hospitalization, 281 (53.8%) patients were ambulatory. Independent predictors of in-hospital ambulation were being married (OR 1.64, 95% CI 1.10–2.49), being non-religious (OR 2.19, 95% CI 1.34–3.62), admission NIHSS (per unit decrease in NIHSS; OR 1.62, 95% CI 1.39–1.91), and non-usage of mechanical venous thromboembolism prophylaxis (OR 1.62, 95% CI 1.02–2.61). After adjusting for confounders, ambulatory patients had lower rates of venous thromboembolism (OR 0.47, 95% CI 0.25–0.89), deep venous thrombosis (OR 0.36, 95% CI 0.17–0.73), prolonged length of hospital stay (OR 0.24, 95% CI 0.16–0.37), and mortality (OR 0.43, 95% CI 0.21–0.84). Conclusions Our findings suggest that for hospitalized acute mild ischemic stroke patients, ambulatory status is an independent predictor of venous thromboembolism (specifically deep venous thrombosis), hospital length of stay, and in-hospital mortality. PMID:27423367

  18. Focal Venous Hypertension as a Pathophysiologic Mechanism for Tissue Hypertrophy, Port-Wine Stains, the Sturge-Weber Syndrome, and Related Disorders: Proof of Concept with Novel Hypothesis for Underlying Etiological Cause (An American Ophthalmological Society Thesis)

    PubMed Central

    Parsa, Cameron F.

    2013-01-01

    Purpose: To provide an in-depth re-examination of assumed causes of tissue hypertrophy, port-wine stains, and the Sturge-Weber, Cobb, Klippel-Trénaunay, and related syndromes to support an alternative unifying pathophysiologic mechanism of venous dysplasia producing focal venous hypertension with attendant tissue responses; to provide proof of concept with new patient data; to propose a novel etiological hypothesis for the venous dysplasia in these syndromes and find supportive evidence. Methods: Data from 20 patients with port-wine stains and corneal pachymetry readings was collected prospectively by the author in an institutional referral-based practice. The literature was searched using MEDLINE, and articles and textbooks were obtained from the bibliographies of these publications. Results: Newly obtained dermatologic, corneal pachymetry, fundus ophthalmoscopic, ocular and orbital venous Doppler ultrasonography, and magnetic resonance imaging findings in patients with the Sturge-Weber syndrome or isolated port-wine stains, along with published data, reveal diffusely thickened tissues and neural atrophy in all areas associated with venous congestion. Conclusions: Contrary to traditional understanding, signs and symptoms in the Sturge-Weber and related syndromes, including both congenital and acquired port-wine stains, are shown to arise from effects of localized primary venous dysplasia or acquired venous obstruction rather than neural dysfunction, differentiating these syndromes from actual phacomatoses. Effects of focal venous hypertension are transmitted to nearby areas via compensatory collateral venous channels in the above conditions, as in the Parkes Weber syndrome. A novel underlying etiology—prenatal venous thrombo-occlusion—is proposed to be responsible for the absence of veins with persistence and enlargement of collateral circulatory pathways with data in the literature backing this offshoot hypothesis. The mechanism for isolated pathologic tissue hypertrophy in these syndromes clarifies physiologic mechanisms for exercise-induced muscle hypertrophy to occur via venous compression and increased capillary transudation. PMID:24385674

  19. Effects of cell salvage on erythrocyte 2,3-disphosphoglycerate and G-6-PD levels and phosphatidylserine expression.

    PubMed

    Che, J; Tian, M; Ding, G; Huai, Q; Dong, P; Li, Y; Li, S

    2013-08-01

    The aim of this study was to investigate the contribution of the perioperative cell salvage process to the changes in erythrocyte 2,3-disphosphoglycerate (2,3-DPG) and glucose-6-phosphate dehydrogenase (G-6-PD) levels and phosphatidylserine (PS) expression using a self-control study comparing washed blood with venous blood. Thirty patients undergoing elective heart and blood vessel surgery were enrolled. Blood was collected and processed using a Fresenius continuous autotransfusion system device. 2,3-DPG and G-6-PD activities, as well as PS expression, from both venous and washed red blood cells (RBC) were measured. We also compared these indicators among washed RBC at 6 h, washed RBC at 0 h, and venous RBC. 2,3-DPG and G-6-PD activities in washed blood at 0 h were significantly higher than in venous RBC (2,3-DPG, venous vs. washed blood P < 0.05; G-6-PD, venous vs. washed blood P < 0.05). Flow cytometry results showed no differences between venous blood and washed RBC at 0 h (n = 23, P > 0.05). 2,3-DPG activity in washed RBC that were allowed to stand for 6 h decreased compared with that in venous blood (venous vs. washed blood at 6 h P < 0.01), whereas no significant difference was observed in G-6-PD activity (venous. vs. washed blood at 6 h P > 0.05). Compared with venous RBC, washed RBC from intraoperative cell salvage exhibited good oxygen-carrying and antioxidant capacities. However, the oxygen-carrying capacity of washed RBC that were allowed to stand for 6 h was not as good as that of venous RBC. Thus, we suggest that washed RBC that were left to stand for more than 6 h should not be reinfused. © 2012 John Wiley & Sons Ltd.

  20. Venous thromboembolism prophylaxis in gynecologic surgery: a systematic review.

    PubMed

    Rahn, David D; Mamik, Mamta M; Sanses, Tatiana V D; Matteson, Kristen A; Aschkenazi, Sarit O; Washington, Blair B; Steinberg, Adam C; Harvie, Heidi S; Lukban, James C; Uhlig, Katrin; Balk, Ethan M; Sung, Vivian W

    2011-11-01

    To comprehensively review and critically assess the available gynecologic surgery venous thromboembolism prophylaxis literature and provide clinical practice guidelines. MEDLINE and Cochrane databases from inception to July 2010. We included randomized controlled trials in gynecologic surgery populations. Interventions and comparators included graduated compression stockings, intermittent pneumatic compression, unfractionated heparin, and low molecular weight heparin; placebo and routine postoperative care were allowed as comparators. One thousand two hundred sixty-six articles were screened, and 14 randomized controlled trials (five benign gynecologic, nine gynecologic oncology) met eligibility criteria. In addition, nine prospective or retrospective studies with at least 150 women were identified and provided data on venous thromboembolism risk stratification, gynecologic laparoscopy, and urogynecologic populations. Two reviewers independently screened articles with discrepancies adjudicated by a third. Eligible randomized controlled trials were extracted for these characteristics: study, participant, surgery, intervention, comparator, and outcomes data, including venous thromboembolism incidence and bleeding complications. Studies were individually and collectively assessed for methodologic quality and strength of evidence. Overall incidence of clinical venous thromboembolism was 0-2% in the benign gynecologic population. With use of intermittent pneumatic compression for benign major procedures, venous thromboembolism incidence was less than 1%. No venous thromboembolisms were identified in prospective studies of benign laparoscopic procedures. Overall quality of evidence in the benign gynecologic literature was poor. Gynecologic-oncology randomized controlled trials reported venous thromboembolism incidence (including "silent" venous thromboembolisms) of 0-14.8% with prophylaxis and up to 34.6% without prophylaxis. Fair quality of evidence supports that unfractionated heparin and intermittent pneumatic compression are both superior to placebo or no intervention but insufficient to determine whether heparins are superior to intermittent pneumatic compression for venous thromboembolism prevention. Combining two of three risks (aged 60 years or older, cancer, or personal venous thromboembolism history) substantially elevated the risk of venous thromboembolism. Intermittent pneumatic compression provides sufficient prophylaxis for the majority of gynecology patients undergoing benign surgery. Additional risk factors warrant the use of combined mechanical and pharmacologic prophylaxis.

  1. Comparison of Interstitial Fluid pH, PCO2, PO2 with Venous Blood Values During Repetitive Handgrip Exercise

    NASA Technical Reports Server (NTRS)

    Hagan, Ronald Donald; Soller, Babs R.; Shear, Michael; Walz, Matthias; Landry, Michelle; Heard, Stephen

    2006-01-01

    We evaluated the use of a small, fiber optic sensor to measure pH, PCO2 and PO2 from forearm muscle interstitial fluid (IF) during handgrip dynamometry. PURPOSE: Compare pH, PCO2 and PO2 values obtained from venous blood with those from the IF of the flexor digitorum superficialis (FDS) during three levels of exercise intensity. METHODS: Six subjects (5M/1F), average age 29+/-5 yrs, participated in the study. A venous catheter was placed in the retrograde direction in the antecubital space and a fiber optic sensor (Paratrend, Diametrics Medical, Inc.) was placed through a 22 G catheter into the FDS muscle under ultrasound guidance. After a 45 min rest period, subjects performed three 5-min bouts of repetitive handgrip exercise (2s contraction/1 s relaxation) at attempted levels of 15%, 30% and 45% of maximal voluntary contraction. The order of the exercise bouts was random with the second and third bouts started after blood lactate had returned to baseline. Venous blood was sampled every minute during exercise and analyzed with an I-Stat CG-4+ cartridge, while IF fiber optic sensor measurements were obtained every 2 s. Change from pre-exercise baseline to end of exercise was computed for pH, PCO2 and PO2. Blood and IF values were compared with a paired t-test. RESULTS: Baseline values for pH, PCO2 and PO2 were 7.37+/-0.02, 46+/-4 mm Hg, and 36+/-6 mm Hg respectively in blood and 7.39+/-0.02, 44+/-6 mm Hg, and 35+/-14 mm Hg in IF. Average changes over all exercise levels are noted in the Table below. For each parameter the exercise-induced change was at least twice as great in IF as in blood. In blood and IF, pH and PCO2 increases were directly related to exercise intensity. Change in venous PO2 was unrelated to exercise intensity, while IF PO2 decreased with increases in exercise intensity. CONCLUSIONS: Measurement of IF pH, PCO2 and PO2 is more sensitive to exercise intensity than measurement of the same parameters in venous blood and provides continuous assessment during and after exercise.

  2. C-Arm Computed Tomography-Assisted Adrenal Venous Sampling Improved Right Adrenal Vein Cannulation and Sampling Quality in Primary Aldosteronism.

    PubMed

    Park, Chung Hyun; Hong, Namki; Han, Kichang; Kang, Sang Wook; Lee, Cho Rok; Park, Sungha; Rhee, Yumie

    2018-05-04

    Adrenal venous sampling (AVS) is a gold standard for subtype classification of primary aldosteronism (PA). However, this procedure has a high failure rate because of the anatomical difficulties in accessing the right adrenal vein. We investigated whether C-arm computed tomography-assisted AVS (C-AVS) could improve the success rate of adrenal sampling. A total of 156 patients, diagnosed with PA who underwent AVS from May 2004 through April 2017, were included. Based on the medical records, we retrospectively compared the overall, left, and right catheterization success rates of adrenal veins during the periods without C-AVS (2004 to 2010, n=32) and with C-AVS (2011 to 2016, n=134). The primary outcome was adequate bilateral sampling defined as a selectivity index (SI) >5. With C-AVS, the rates of adequate bilateral AVS increased from 40.6% to 88.7% (P<0.001), with substantial decreases in failure rates (43.7% to 0.8%, P<0.001). There were significant increases in adequate sampling rates from right (43.7% to 91.9%, P<0.001) and left adrenal veins (53.1% to 95.9%, P<0.001) as well as decreases in catheterization failure from right adrenal vein (9.3% to 0.0%, P<0.001). Net improvement of SI on right side remained significant after adjustment for left side (adjusted SI, 1.1 to 9.0; P=0.038). C-AVS was an independent predictor of adequate bilateral sampling in the multivariate model (odds ratio, 9.01; P<0.001). C-AVS improved the overall success rate of AVS, possibly as a result of better catheterization of right adrenal vein. Copyright © 2018 Korean Endocrine Society.

  3. Methods for the field evaluation of quantitative G6PD diagnostics: a review.

    PubMed

    Ley, Benedikt; Bancone, Germana; von Seidlein, Lorenz; Thriemer, Kamala; Richards, Jack S; Domingo, Gonzalo J; Price, Ric N

    2017-09-11

    Individuals with glucose-6-phosphate dehydrogenase (G6PD) deficiency are at risk of severe haemolysis following the administration of 8-aminoquinoline compounds. Primaquine is the only widely available 8-aminoquinoline for the radical cure of Plasmodium vivax. Tafenoquine is under development with the potential to simplify treatment regimens, but point-of-care (PoC) tests will be needed to provide quantitative measurement of G6PD activity prior to its administration. There is currently a lack of appropriate G6PD PoC tests, but a number of new tests are in development and are likely to enter the market in the coming years. As these are implemented, they will need to be validated in field studies. This article outlines the technical details for the field evaluation of novel quantitative G6PD diagnostics such as sample handling, reference testing and statistical analysis. Field evaluation is based on the comparison of paired samples, including one sample tested by the new assay at point of care and one sample tested by the gold-standard reference method, UV spectrophotometry in an established laboratory. Samples can be collected as capillary or venous blood; the existing literature suggests that potential differences in capillary or venous blood are unlikely to affect results substantially. The collection and storage of samples is critical to ensure preservation of enzyme activity, it is recommended that samples are stored at 4 °C and testing occurs within 4 days of collection. Test results can be visually presented as scatter plot, Bland-Altman plot, and a histogram of the G6PD activity distribution of the study population. Calculating the adjusted male median allows categorizing results according to G6PD activity to calculate standard performance indicators and to perform receiver operating characteristic (ROC) analysis.

  4. Venous and autonomic function in formerly pre-eclamptic women and BMI-matched controls.

    PubMed

    Heidema, Wieteke M; van Drongelen, Joris; Spaanderman, Marc E A; Scholten, Ralph R

    2018-03-25

    Pre-pregnancy reduced plasma volume increases the risk on subsequent pre-eclamptic pregnancy. Reduced plasma volume is thought to reflect venous reserve capacity, especially when venous vasculature is constricted and sympathetic tone is elevated. As obesity might affect these variables and also relates to pre-eclampsia, increased body weight may underlie these observations. We hypothesized that the relationship between reduced venous reserve and preeclampsia is independent of body mass index (BMI). We compared the non-pregnant venous reserve capacity in 30 formerly pre-eclamptic women, equally divided in 3 BMI-classes (BMI 19.5-24.9, BMI 25-29.9, BMI ≥30) to 30 controls. Cases and controls were matched for BMI, age and parity. The venous reserve capacity was quantified by assessing plasma volume and venous compliance. The autonomic nervous system regulating the venous capacitance was evaluated with heart rate variability analysis in resting supine position and during positive head-up tilt (HUT). Formerly pre-eclamptic women had in supine position lower plasma volume than controls (1339 ± 79 vs 1547 ± 139 ml/m 2 (p<0.001)), lower venous compliance (0.04 ± 0.02 vs 0.07 ± 0.02 ml/dl/mmHg (p<0.001)), higher sympathetic tone (1.9 ± 0.1 vs 1.2 ± 0.7 mmHg 2 (p=0.002)) and lower baroreceptor sensitivity (8.7 ± 3.8 vs 19.0 ± 1.7 ms/mmHg (p<0.001)). During HUT, women with a history of preeclampsia have less modulatory capacity over venous compliance and baroreceptor sensitivity, while heart rate and sympathetic tone remain consistently higher. Women with a history of pre-eclampsia have, compared to BMI-matched controls, reduced venous reserve capacity. This is reflected by lower plasma volume and venous compliance, the autonomic balance is shifted towards sympathetic dominance and lower baroreceptor sensitivity. This suggests that not BMI, but underlying reduced venous reserve relates to pre-eclampsia. This article is protected by copyright. All rights reserved.

  5. Comparison of Hand-Sewn versus Coupled Venous Anastomoses in Traumatic Lower Extremity Reconstruction.

    PubMed

    Stranix, John T; Rifkin, William J; Lee, Z-Hye; Anzai, Lavinia; Jacoby, Adam; Ceradini, Daniel J; Thanik, Vishal; Saadeh, Pierre B; Levine, Jamie P

    2018-06-15

     Microvascular reconstruction of the lower extremity has the highest reported complication and flap failure rates of any anatomical region. Despite widespread adoption of the mechanical anastomotic venous coupler and encouraging results in other anatomical regions, there are limited reports examining its use in the lower extremity. This study compares outcomes between coupled and hand-sewn venous anastomoses in traumatic lower extremity reconstruction.  Retrospective review of our institutional flap registry from 1979 to 2016 identified soft tissue free flaps performed for the reconstruction of Gustilo type IIIB/IIIC open tibial fractures. Patient demographics, flap characteristics, use of a venous anastomotic coupler, and perioperative outcomes were examined. Analysis was performed using chi-square and Student's t -tests.  A total of 361 patients received a microvascular free flap for coverage of a Gustilo type IIIB or IIIC tibial fracture following traumatic injury. After excluding cases that lacked adequate information on coupler use, 358 free flaps were included in the study. There were 72 (20%) free flaps performed using a venous coupler and 286 (80%) performed with hand-sewn venous anastomoses. There were comparable rates of major complications (22.2 vs. 26.1%; p  = 0.522), total flap failure (6.5%, vs. 10.2%; p  = 0.362), and partial flap failure (9.7 vs. 12.2%; p  = 0.579) between venous coupler and hand-sewn anastomoses, respectively. Furthermore, use of the venous coupler was not associated with increased rates of operative take backs (22.8 vs. 23.0%; p  = 0.974). However, reconstructions performed using a venous coupler were significantly more likely to have a second venous anastomosis performed (37.5 vs. 21.3%; p  = 0.004).  Complication and flap failure rates were similar between reconstructions performed with a venous coupler and those performed with hand-sewn venous anastomoses. These findings suggest that use of the venous anastomotic coupler is safe and effective in lower extremity reconstruction, with comparable outcomes to conventional sutured anastomoses. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  6. Certain aspects of human metabolism during spaceflights of varying duration

    NASA Technical Reports Server (NTRS)

    Grigoryev, A. I.; Popova, I. A.; Ushakov, A. S.

    1988-01-01

    A comparative analysis is made of hormone reactions after short and long term spaceflights. Endocrinological indicators from venous blood and daily urine samples of cosmonauts completing flights lasting from 7 to 237 days were examined. No pathological indicators were found in the metabolic shifts in the erythrocytes and disruption of the functional state of their membranes.

  7. Radionuclide plethysmography and Tc-99m red blood cell venography in venous thrombosis: comparison with contrast venography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Singer, I.; Royal, H.D.; Uren, R.F.

    1984-01-01

    Radionuclide plethysmography (RPG) is a new technique that uses Tc-99m labelled red blood cells to ascertain changes in venous volumes by detecting the change in counts in response to the inflation and deflation of proximal thigh cuffs. Diagnosis of ileofemoral venous occlusion is possible using this technique, which also provides kinetic data of venous outflow. Twenty-one patients with suspected deep venous thrombosis were studied prospectively using RPG, radionuclide venography (RV), and contrast venography (CV) to establish the usefulness of RPG alone and in combination wth RV in the diagnosis of ileofemoral venous thrombosis (sensitivity, 91%; specificity, 100%). RV was lessmore » sensitive (73%) and less specific (93%) in diagnosing that condition.« less

  8. Warfarin-induced Venous Limb Gangrene

    PubMed Central

    Grim Hostetler, Sarah; Sopkovich, Jennifer; Dean, Steven

    2012-01-01

    Warfarin is a commonly used anticoagulant that has been associated with several significant cutaneous side effects, most notably warfarin-induced skin necrosis. A lesser known adverse reaction to warfarin is warfarin-induced venous limb gangrene. Both cutaneous adverse effects share the same pathophysiology, but are clinically quite different. The majority of cases of warfarin-induced venous limb gangrene has been in patients with cancer or heparin-induced thrombocytopenia. However, other hypercoagulable disease states, such as the antiphospholipid antibody syndrome, can be associated with venous limb gangrene. In order to increase recognition of this important condition, the authors report a case of warfarin-induced venous limb gangrene in a patient with presumed antiphospholipid antibody syndrome and review the literature on warfarin-induced venous limb gangrene. PMID:23198012

  9. Anomalous pulmonary venous connection: An underestimated entity.

    PubMed

    Magalhães, Sara P; Moreno, Nuno; Loureiro, Marília; França, Manuela; Reis, Fernanda; Alvares, Sílvia; Ribeiro, Manuel

    2016-12-01

    Anomalous pulmonary venous connection is an uncommon congenital anomaly in which all (total form) or some (partial form) pulmonary veins drain into a systemic vein or into the right atrium rather than into the left atrium. The authors present one case of total anomalous pulmonary venous connection and two cases of partial anomalous pulmonary venous connection, one of supracardiac drainage into the brachiocephalic vein, and the other of infracardiac anomalous venous drainage (scimitar syndrome). Through the presentation of these cases, this article aims to review the main pulmonary venous developmental defects, highlighting the role of imaging techniques in the assessment of these anomalies. Copyright © 2016 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.

  10. Series of Noncontrast Time-of-Flight Magnetic Resonance Angiographies to Identify Problems with Arteriovenous Fistula Maturation.

    PubMed

    Gonzalez, Aaron J; Casey, Kevin M; Drinkwine, Benjamin J; Weiss, Jeffrey S

    2016-01-01

    Successful maturation of arteriovenous fistulas (AVFs) remains a challenge for those managing patients with end-stage renal disease. Time-of-flight magnetic resonance angiography (TOF-MR) can be used to evaluate AVFs without the risk of radiation exposure, intravenous contrast, or reliance on the operator-dependent modality of color Doppler ultrasonography (CDUS). The objective of our study was to assess the utility of TOF-MR in the evaluation of nonmaturing AVFs and to identify the best clinical situations to use this technology. Consecutive patients with abnormal findings on CDUS or physical examination after AVF creation underwent 3-dimensional (3D) TOF-MR. Imaging was performed at 3 T with a scan acquisition time of approximately 15 min. The technique was similar to head and neck magnetic resonance angiography (MRA), except presaturation bands were not used, thereby allowing simultaneous visualization of both arterial and venous flow. A total of 19 TOF-MR studies were performed. Nineteen patients underwent imaging and were the focus of this study. Seventeen of 19 TOF-MR studies were of diagnostic quality and yielded findings which enabled the vascular surgeon to take corrective measures. Findings included inflow stenosis, anastomotic narrowing, venous outflow stenosis, and hemodynamically significant venous tributaries. Twelve of 17 patients required conventional digital subtraction angiography (DSA). The congruence rate between TOF-MR and DSA was 83.3%. Four patients (21%) avoided DSA and went directly to definitive surgical treatment including branch ligation (3) or new access (1). This is the first report in the literature of successful implementation of 3D TOF-MR to assist in identifying AVF maturation problems. This unique noninvasive imaging modality provides actionable images without contrast or radiation exposure and can obviate the need for invasive diagnostic procedures or provide an anatomic map for planning corrective intervention. Published by Elsevier Inc.

  11. Acute but not chronic metabolic acidosis potentiates the acetylcholine-induced reduction in blood pressure: an endothelium-dependent effect

    PubMed Central

    Celotto, A.C.; Ferreira, L.G.; Capellini, V.K.; Albuquerque, A.A.S.; Rodrigues, A.J.; Evora, P.R.B.

    2015-01-01

    Metabolic acidosis has profound effects on vascular tone. This study investigated the in vivo effects of acute metabolic acidosis (AMA) and chronic metabolic acidosis (CMA) on hemodynamic parameters and endothelial function. CMA was induced by ad libitum intake of 1% NH4Cl for 7 days, and AMA was induced by a 3-h infusion of 6 M NH4Cl (1 mL/kg, diluted 1:10). Phenylephrine (Phe) and acetylcholine (Ach) dose-response curves were performed by venous infusion with simultaneous venous and arterial blood pressure monitoring. Plasma nitrite/nitrate (NOx) was measured by chemiluminescence. The CMA group had a blood pH of 7.15±0.03, which was associated with reduced bicarbonate (13.8±0.98 mmol/L) and no change in the partial pressure of arterial carbon dioxide (PaCO2). The AMA group had a pH of 7.20±0.01, which was associated with decreases in bicarbonate (10.8±0.54 mmol/L) and PaCO2 (47.8±2.54 to 23.2±0.74 mmHg) and accompanied by hyperventilation. Phe or ACh infusion did not affect arterial or venous blood pressure in the CMA group. However, the ACh infusion decreased the arterial blood pressure (ΔBP: -28.0±2.35 mm Hg [AMA] to -4.5±2.89 mmHg [control]) in the AMA group. Plasma NOx was normal after CMA but increased after AMA (25.3±0.88 to 31.3±0.54 μM). These results indicate that AMA, but not CMA, potentiated the Ach-induced decrease in blood pressure and led to an increase in plasma NOx, reinforcing the effect of pH imbalance on vascular tone and blood pressure control. PMID:26648089

  12. [The value of radial shock wave therapy in the management of extended crural ulceration. Case report].

    PubMed

    Fekete, László; Nagy, György Ádám; Diamant, Péter Kamilló; Halmy, Csaba; Zentai, Agnes

    2014-11-09

    The authors present the history of a 36-year-old woman who had crural ulceration in the ventral side of the left lower limb due to venous circulatory failure for 5 years. In addition to the application of dressing adapted to the actual status of the wound, the authors applied an extracorporal shock wave therapy two times per week. After this treatment the size of the ulcer significantly decreased and it became suitable for mesh-graft cover. The patient is currently asymptomatic. The authors draw attention to the fact that the number of patients having crural ulcer is increasing in developed countries including Hungary. Lower limb ulcers occur in 1-5% of the adult population. Predisposing factors include older age and civilization hazards such as obesity, diabetes and sedentary lifestyle. The main cause of the disease is circulatory failure; venous insufficiency occurs in about two-thirds of the patients, arterial ischemia in 15% and diabetic angiopathy in 15% of the cases. Infections, metabolic diseases and immunological disorders may be also an underlying cause in a small number of patients. In several patients the causative factors occur simultaneously making difficult to find and effective treatment. Despite the use of numerous preventive and therapeutic protocols, treatment is usually long and does not always match expectations of the patients.

  13. The effect of nitroglycerin on microvascular perfusion and oxygenation during gastric tube reconstruction.

    PubMed

    Buise, Marc P; Ince, Can; Tilanus, Hugo W; Klein, Jan; Gommers, Diederik; van Bommel, Jasper

    2005-04-01

    Esophagectomy followed by gastric tube reconstruction is the surgical treatment of choice for patients with esophageal cancer. Complications of the cervical anastomosis are associated with impaired microvascular blood flow (MBF) and ischemia in the gastric fundus. The aim of the present study was to differentiate whether the decrease in MBF is a result of arterial insufficiency or of venous congestion. To do this we assessed MBF, microvascular hemoglobin oxygen saturation (muHbSo(2)), and microvascular hemoglobin concentration (muHbcon) simultaneously during different stages of gastric tube reconstruction. In 14 patients, MBF was determined with laser Doppler flowmetry, and muHbSo(2) and muHbcon were determined with reflectance spectro- photometry. After completion of the anastomosis, nitroglycerin was applied at the fundus. Although MBF did not change significantly in the pylorus, MBF decreased progressively during surgery in the fundus from 210 +/- 18 Arbitrary Units at baseline (normal stomach) to 52 +/- 9 Arbitrary Units after completion of reconstruction (mean +/- sem; P < 0.05). There was no change in muHbSo(2) and muHbcon during the reconstruction. After application of nitroglycerin, MBF doubled. We conclude that MBF decreases during gastric tube reconstruction but that muHbSo(2) and muHbcon do not. This decrease might be the result of venous congestion, which can partly be counteracted by application of nitroglycerin.

  14. Immediate ventilatory response to sudden changes in venous return in humans.

    PubMed Central

    Cummin, A R; Iyawe, V I; Jacobi, M S; Mehta, N; Patil, C P; Saunders, K B

    1986-01-01

    We changed venous return transiently by postural manoeuvres, and by lower body positive pressure, to see what happened simultaneously to ventilation. Cardiac output was measured by a Doppler technique. In seven subjects, after inflation of a pressure suit to 80 and 40 mmHg at 30 deg head-up tilt, both cardiac output and ventilation increased. Ventilation increased rapidly to a peak in the first 5 s, cardiac output more slowly to a steady state in about 20 s, at 80 mmHg inflation. After inflation to 80 mmHg in six subjects at 12.5 deg head-up and 30 deg head-down tilt, cardiac output did not change in the first, and fell in the second case. There were no significant changes in ventilation. On release of pressure there were transient increases in both cardiac output and ventilation, with ventilation lagging behind cardiac output, in contrast to (2) above. In five subjects, elevation of the legs at 30 deg head-up tilt caused a rise in both cardiac output and ventilation, but in two subjects neither occurred. In all seven subjects there was a transient increase in cardiac output and ventilation when the legs were lowered. Ventilation and cardiac output changes were approximately in phase. We were therefore unable to dissociate entirely increasing cardiac output from increasing ventilation. The relation between them was certainly not a simple proportional one. PMID:3612571

  15. Reflex respiratory and cardiovascular effects of stimulation of receptors in the nose of the dog.

    PubMed

    James, J E; De Burgh Daly, M

    1972-02-01

    1. In forty-one out of forty-seven dogs under chloralose-urethane or Nembutal anaesthesia, mechanical stimulation of the nasal mucous membrane caused a reduction or inhibition of respiration, bradycardia, variable changes of arterial blood pressure, and a small rise in venous pressure.2. Simultaneous measurements of arterial and venous pressures, and also of blood flow in various arteries by means of an electromagnetic flowmeter indicate that the calculated vascular resistance increases in the intact limb, muscle, and skin, and the vascular beds of the vertebral, superior mesenteric, renal and splenic arteries. No changes in vascular resistance occur in the common carotid circulation.3. Evidence is presented that the increase in vascular resistance is due to vasoconstriction, and occurs in the absence of changes in pulmonary ventilation.4. Stimulation of the nasal mucous membrane causes a reduction in volume of the spleen.5. The respiratory and cardiovascular responses are reflex in nature, being abolished by the application of a local anaesthetic to the nose or by combined division of the maxillary and ethmoidal branches of the trigeminal nerves. The cardiac response is mediated largely by the vagus nerves, and the vascular responses by sympathetic adrenergic fibres.6. Cessation of the stimulus to the nose not infrequently results in the following temporary after-effects: hyperventilation, tachycardia, hypertension, and vasodilatation in the intact limb and in muscle.

  16. Connective tissue-activating peptide III: a novel blood biomarker for early lung cancer detection.

    PubMed

    Yee, John; Sadar, Marianne D; Sin, Don D; Kuzyk, Michael; Xing, Li; Kondra, Jennifer; McWilliams, Annette; Man, S F Paul; Lam, Stephen

    2009-06-10

    There are no reliable blood biomarkers to detect early lung cancer. We used a novel strategy that allows discovery of differentially present proteins against a complex and variable background. Mass spectrometry analyses of paired pulmonary venous-radial arterial blood from 16 lung cancer patients were applied to identify plasma proteins potentially derived from the tumor microenvironment. Two differentially expressed proteins were confirmed in 64 paired venous-arterial blood samples using an immunoassay. Twenty-eight pre- and postsurgical resection peripheral blood samples and two independent, blinded sets of plasma from 149 participants in a lung cancer screening study (49 lung cancers and 100 controls) and 266 participants from the National Heart Lung and Blood Institute Lung Health Study (45 lung cancer and 221 matched controls) determined the accuracy of the two protein markers to detect subclinical lung cancer. Connective tissue-activating peptide III (CTAP III)/ neutrophil activating protein-2 (NAP-2) and haptoglobin were identified to be significantly higher in venous than in arterial blood. CTAP III/NAP-2 levels decreased after tumor resection (P = .01). In two independent population cohorts, CTAP III/NAP-2 was significantly associated with lung cancer and improved the accuracy of a lung cancer risk prediction model that included age, smoking, lung function (FEV(1)), and an interaction term between FEV(1) and CTAP III/NAP-2 (area under the curve, 0.84; 95% CI, 0.77 to 0.91) compared to CAPIII/NAP-2 alone. We identified CTAP III/NAP-2 as a novel biomarker to detect preclinical lung cancer. The study underscores the importance of applying blood biomarkers as part of a multimodal lung cancer risk prediction model instead of as stand-alone tests.

  17. Successful Adrenal Venous Sampling by Non-experts with Reference to CT Images

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Morita, Satoru, E-mail: i@imodey.com; Yamazaki, Hiroshi; Sonoyama, Yasuyuki

    PurposeTo establish technical success rates and safety of adrenal venous sampling (AVS) performed by non-experts with reference to CT images.Materials and Methods104 AVS procedures with adrenocorticotropic hormone stimulation were performed for patients with suspected primary aldosteronism. One of three radiology residents with 2nd, 5th, and 5th grade experience undertook the procedure under the guidance of an experienced, board-certified interventional radiologist with reference to contrast-enhanced CT images obtained in 102 cases. Successful catheterization of the adrenal veins was assessed using three criteria: an adrenal venous cortisol concentration of more than 200 μg/dL (criterion A); an adrenal vein/inferior vena cava cortisol ratio ofmore » more than 5:1 (criterion B); and an adrenal vein/inferior vena cava cortisol ratio of more than 10:1 (criterion C).ResultsThe operators were aware of the anatomy of the left adrenal veins in 102 cases (98 %) and of the right adrenal veins in 99 cases (95 %) prior to the procedure. CT identified the correct position of the right adrenal vein orifice in 82 of 99 cases (83 %). The overall technical success rates for AVS from the right adrenal vein according to criteria A, B, and C, were 96, 96, and 94 %, respectively. Those for the left adrenal vein were 97, 98, and 94 %, respectively. No significant differences in success rates were observed between the operators (p = 0.922–0.984). No major complications, including adrenal vein rupture, were observed.ConclusionsWhen CT images are used to guide AVS, the procedure can be performed successfully and safely even by non-experts.« less

  18. Fibrotic Venous Remodeling and Nonmaturation of Arteriovenous Fistulas.

    PubMed

    Martinez, Laisel; Duque, Juan C; Tabbara, Marwan; Paez, Angela; Selman, Guillermo; Hernandez, Diana R; Sundberg, Chad A; Tey, Jason Chieh Sheng; Shiu, Yan-Ting; Cheung, Alfred K; Allon, Michael; Velazquez, Omaida C; Salman, Loay H; Vazquez-Padron, Roberto I

    2018-03-01

    The frequency of primary failure in arteriovenous fistulas (AVFs) remains unacceptably high. This lack of improvement is due in part to a poor understanding of the pathobiology underlying AVF nonmaturation. This observational study quantified the progression of three vascular features, medial fibrosis, intimal hyperplasia (IH), and collagen fiber organization, during early AVF remodeling and evaluated the associations thereof with AVF nonmaturation. We obtained venous samples from patients undergoing two-stage upper-arm AVF surgeries at a single center, including intraoperative veins at the first-stage access creation surgery and AVFs at the second-stage transposition procedure. Paired venous samples from both stages were used to evaluate change in these vascular features after anastomosis. Anatomic nonmaturation (AVF diameter never ≥6 mm) occurred in 39 of 161 (24%) patients. Neither preexisting fibrosis nor IH predicted AVF outcomes. Postoperative medial fibrosis associated with nonmaturation (odds ratio [OR], 1.55; 95% confidence interval [95% CI], 1.05 to 2.30; P =0.03, per 10% absolute increase in fibrosis), whereas postoperative IH only associated with failure in those individuals with medial fibrosis over the population's median value (OR, 2.63; 95% CI, 1.07 to 6.46; P =0.04, per increase of 1 in the intima/media ratio). Analysis of postoperative medial collagen organization revealed that circumferential alignment of fibers around the lumen associated with AVF nonmaturation (OR, 1.38; 95% CI, 1.03 to 1.84; P =0.03, per 10° increase in angle). This study demonstrates that excessive fibrotic remodeling of the vein after AVF creation is an important risk factor for nonmaturation and that high medial fibrosis determines the stenotic potential of IH. Copyright © 2018 by the American Society of Nephrology.

  19. Clinical application of noradrenaline spillover methodology: delineation of regional human sympathetic nervous responses.

    PubMed

    Esler, M

    1993-11-01

    The proportionality which in general exists between rates of sympathetic nerve firing and the overflow of noradrenaline into the venous drainage of an organ provides the experimental justification for the use of measurements of noradrenaline in plasma as a biochemical measure of sympathetic nervous function. Static measurements of noradrenaline plasma concentration have several limitations. One is the confounding influence of noradrenaline plasma clearance on plasma concentration. Other drawbacks include the distortion arising from antecubital venous sampling (this represents but one venous drainage, that of the forearm), and the inability to detect regional differentiation of sympathetic responses. Clinical regional noradrenaline spillover measurements, performed with infusions of radiolabelled noradrenaline and sampling from centrally placed catheters, and derived from regional isotope dilution, overcome these deficiencies. The strength of the methodology is that sympathetic nervous function may be studied in the internal organs not accessible to nerve recording with microneurography. Examples of the regionalization of human sympathetic responses disclosed include the preferential activation of the cardiac sympathetic outflow with mental stress, cigarette smoking, aerobic exercise, cardiac failure, coronary insufficiency, essential hypertension and in ventricular arrhythmias, and the preferential stimulation or inhibition of the renal sympathetic nerves with low salt diets and mental stress, and with exercise training, respectively. By application of the same principles, regional release of the sympathetic cotransmitters neuropeptide Y and adrenaline can be studied in humans. Cotransmitter release, however, is detected only with some difficulty. In restricted circumstances we find evidence of regional cotransmitter release to plasma, such as the release of neuropeptide Y from the heart at the very high rates of sympathetic nerve firing occurring with aerobic exercise, and cardiac adrenaline release also with exercise and after loading of the neuronal adrenaline pool by intravenous infusion of adrenaline.

  20. An Isolated Venous Sac as a Novel Site for Cell Therapy in Diabetes Mellitus

    PubMed Central

    Kakabadze, Zurab; Shanava, Koba; Ricordi, Camillo; Shapiro, A.M. James; Gupta, Sanjeev; Berishvili, Ekaterine

    2013-01-01

    Background Transplanting pancreatic islets is of significant interest for type 1 diabetes mellitus. After intraportal injection of islets, inferior engraftment and eventual loss of transplanted islets constitute major limitations. Therefore, alternative approaches will be helpful. Here, we evaluated in animals whether an isolated venous sac would support survival of transplanted islets, along with correction of hyperglycemia. Methods Pancreatic islets isolated from adult Lewis rats were transplanted either into an isolated venous sac made from lumbar vein or into the portal vein of syngeneic rats. The integrity and vascular organization of the venous sac was determined by studies of the local microcirculation. The engraftment, survival, and function of transplanted islets were analyzed by histology, including endocrine function in situ and by glycemic control in rats with streptozotocin-induced diabetes. Results Transplanted islets showed normal morphology with insulin expression in isolated venous sac during the long term. Transplanted islets received blood supply from vasa vasorum and had access to drainage through venous tributaries in the venous sac. This resulted in restoration of euglycemia in diabetic rats. Removal of islet graft-bearing venous sac in diabetic rats led to recurrence of hyperglycemia. By contrast, euglycemia was not restored in rats treated by intraportal transplantation of islets. Conclusions We demonstrated that pancreatic islets successfully engrafted and functioned in the isolated venous sac with ability to restore euglycemia in diabetic rats. Therefore, the isolated venous sac offers a new site for transplantation of pancreatic islets. This would be clinically beneficial as an alternative to intrahepatic islet transplantation. PMID:22814331

  1. Evidence for Extending the Duration of Chemoprophylaxis following Free Flap Harvest from the Lower Extremity: Prospective Screening for Deep Venous Thrombosis.

    PubMed

    Rau, Aline S; Harry, Brian L; Leem, Ted H; Song, John I; Deleyiannis, Frederic W-B

    2016-08-01

    The purpose of this study was to investigate the incidence of symptomatic and asymptomatic deep venous thrombosis in patients undergoing harvest of a free flap from the lower extremity who were receiving standard chemoprophylaxis while hospitalized. A retrospective review of 65 consecutive patients undergoing surgery between 2011 and 2013 was performed to determine the incidence of symptomatic deep venous thrombosis. These patients were screened for deep venous thrombosis based on development of symptoms. Prospective evaluation of a similar consecutive population of 37 patients between 2014 and 2015 was then performed to determine the incidence of asymptomatic deep venous thrombosis. These patients underwent routine duplex ultrasonography of both legs at postoperative weeks 1 and 4. Symptomatic deep venous thrombosis occurred in 2.9 percent of all patients. In the prospective cohort, 8.1 percent of the patients were found to have an acute deep venous thrombosis by postoperative week 1. At postoperative week 4, 16.7 percent of the patients developed a new, acute deep venous thrombosis. The estimated costs of screening and treating deep venous thrombosis in the retrospective group and the prospective group were $222 and $2259, respectively. The cost of routine chemoprophylaxis without duplex screening for an additional 14 days after discharge was $125 per patient. The rate of asymptomatic deep venous thrombosis may be much higher than previously appreciated in this population of very high-risk patients, especially during the 2 weeks after discharge. Extending the duration of chemoprophylaxis to 4 weeks after surgery may be warranted. Therapeutic, IV.

  2. Lifetime Risk of Venous Thromboembolism in Two Cohort Studies.

    PubMed

    Bell, Elizabeth J; Lutsey, Pamela L; Basu, Saonli; Cushman, Mary; Heckbert, Susan R; Lloyd-Jones, Donald M; Folsom, Aaron R

    2016-03-01

    Greater public awareness of venous thromboembolism may be an important next step for optimizing venous thromboembolism prevention and treatment. "Lifetime risk" is an easily interpretable way of presenting risk information. Therefore, we sought to calculate the lifetime risk of venous thromboembolism (deep vein thrombosis or pulmonary embolism) using data from 2 large, prospective cohort studies: the Cardiovascular Health Study (CHS) and the Atherosclerosis Risk in Communities (ARIC) study. We followed participants aged 45-64 years in ARIC (n = 14,185) and ≥65 in CHS (n = 5414) at baseline visits (1987-1989 in ARIC, 1989-1990 and 1992-1993 in CHS) for incident venous thromboembolism (n = 728 in ARIC through 2011 and n = 172 in CHS through 2001). We estimated lifetime risks and 95% confidence intervals of incident venous thromboembolism using a modified Kaplan-Meier method, accounting for the competing risk of death from other causes. At age 45 years, the remaining lifetime risk of venous thromboembolism in ARIC was 8.1% (95% confidence interval, 7.1-8.7). High-risk groups were African Americans (11.5% lifetime risk), those with obesity (10.9%), heterozygous for the factor V Leiden (17.1%), or with sickle cell trait or disease (18.2%). Lifetime risk estimates differed by cohort; these differences were explained by differences in time period of venous thromboembolism ascertainment. At least 1 in 12 middle-aged adults will develop venous thromboembolism in their remaining lifetime. This estimate of lifetime risk may be useful to promote awareness of venous thromboembolism and guide decisions at both clinical and policy levels. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Central venous recanalization in patients with short gut syndrome: restoration of candidacy for intestinal and multivisceral transplantation.

    PubMed

    Lang, Elvira V; Reyes, Jorge; Faintuch, Salomao; Smith, Amy; Abu-Elmagd, Kareem

    2005-09-01

    To assess feasibility and success of venous recanalization in patients with short gut syndrome who have lost their traditional central venous access and required intestinal or multivisceral transplantation. Twelve patients between the ages of 7 and 55 years with short gut syndrome and long-standing total parenteral nutrition (TPN) dependency and/or hypercoagulability were treated. All had extensive chronic central venous occlusions and survival was dependent on restoration of access and planned transplantation. Central venous recanalizations were obtained via sharp needle recanalization techniques, venous reconstructions with stents, and/or extraanatomic access to the central venous system for placement of central venous tunneled catheters. Central venous access was restored in all patients without operative-related mortality. Three major hemodynamic perioperative technical complications were recorded and successfully treated. There were three self-limited early infectious complications. With a mean follow-up of 22 months, eight of the 12 patients were alive with successful small bowel or multivisceral transplantation; six of those became independent of TPN. The remaining four patients died of complications related to TPN (n = 3) or transplantation (n = 1). With a mean follow-up of 20 months, all but two of the recanalized venous accesses were maintained, for a success rate of 83%. Recanalizations of extensive chronic vein occlusions are feasible but associated with high risk. The technique is life-saving for TPN-dependent patients and can restore candidacy for intestinal and multivisceral transplantation. This approach is likely to be increasingly requested because of the current clinical availability of the transplant procedure.

  4. Value of the portal venous phase in evaluation of treated hepatocellular carcinoma following transcatheter arterial chemoembolisation.

    PubMed

    Lam, A; Fernando, D; Sirlin, C C; Nayyar, M; Goodwin, S C; Imagawa, D K; Lall, C

    2017-11-01

    To evaluate the utility of the portal venous phase on multiphasic computed tomography (CT) after treatment of hepatocellular carcinoma (HCC) with trans-arterial chemoembolisation (TACE). This was a retrospective review of patients who underwent TACE for HCC between 1 April 2012 and 21 December 2014, with appropriate multiphasic, pre- and post-procedural CT examinations. The maximum non-contrast, arterial phase, and portal venous phase attenuation values of the tumour and tumour bed were evaluated within a region of interest (ROI), with values adjusted against background hepatic parenchyma. Linear regression analyses were performed for both the arterial and venous phases, to assess the level of enhancement and to determine if the venous phase had additional value in this setting. A total of 86 cases from 51 patients were reviewed. All pre-procedural CT examinations of lesions demonstrated arterial phase enhancement with portal venous and delayed phase washout compatible with HCC. The post-procedural CT examinations following TACE revealed expected decreased arterial enhancement. Sixty-five cases (76%) showed persistent non-enhancement on the portal venous phase following embolisation therapy. A total of 21 cases (24%), however, demonstrated progressive portal venous hyper enhancement. Linear regression analysis demonstrated a statistical significance between the difference in maximal arterial and portal venous enhancement in these cases. Following TACE, the treated lesion may demonstrate portal venous phase hyper-enhancement within the tumour bed. As such, full attention should be given to these images for comprehensive evaluation of tumour response following treatment. Copyright © 2017 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  5. Risk factors for venous port migration in a single institute in Taiwan.

    PubMed

    Fan, Wen-Chieh; Wu, Cheng-Han; Tsai, Ming-Ju; Tsai, Ying-Ming; Chang, Hsu-Liang; Hung, Jen-Yu; Chen, Pei-Huan; Yang, Chih-Jen

    2014-01-14

    An implantable port device provides an easily accessible central route for long-term chemotherapy. Venous catheter migration is one of the rare complications of venous port implantation. It can lead to side effects such as pain in the neck, shoulder, or ear, venous thrombosis, and even life-threatening neurologic problems. To date, there are few published studies that discuss such complications. This retrospective study of venous port implantation in a single center, a Taiwan hospital, was conducted from January 2011 to March 2013. Venous port migration was recorded along with demographic and characteristics of the patients. Of 298 patients with an implantable import device, venous port migration had occurred in seven, an incidence rate of 2.3%. All seven were male and had received the Bard port Fr 6.6 which had smaller size than TYCO port Fr 7.5 and is made of silicon. Significantly, migration occurred in male patients (P = 0.0006) and in those with lung cancer (P = 0.004). Multivariable logistic regression analysis revealed that lung cancer was a significant risk factor for port migration (odds ratio: 11.59; P = 0.0059). The migration rate of the Bard port Fr 6.6 was 6.7%. The median time between initial venous port implantation and port migration was 35.4 days (range, 7 to 135 days) and 71.4% (5/7) of patients had port migration within 30 days after initial port implantation. Male sex and lung cancer are risk factors for venous port migration. The type of venous port is also an important risk factor.

  6. To what extent might deep venous thrombosis and chronic venous insufficiency share a common etiology?

    PubMed

    Malone, P Colm; Agutter, P S

    2009-08-01

    According to the valve cusp hypoxia hypothesis (VCHH), deep venous thrombosis is caused by sustained non-pulsatile (streamline) venous blood flow. This leads to hypoxemia in the valve pockets; hypoxic injury to the inner (parietalis) endothelium of the cusp leaflets activates the elk-1/egr-1 pathway, leading to leukocyte and platelet swarming at the site of injury and, potentially, blood coagulation. Here, we propose an extension of the VCHH to account for chronic venous insufficiency. First, should the foregoing events not proceed to frank thrombogenesis, the valves may nevertheless be chronically injured and become incompetent. Serial incompetence in lower limb valves may then generate ''passive'' venous hypertension. Second, should ostial valve thrombosis obstruct venous return from muscles via tributaries draining into the femoral vein, as Virchow illustrated, ''active'' venous hypertension may supervene: muscle contraction would force the blood in the vessels behind the blocked ostial valves to re-route. Passive or active venous hypertension opposes return flow, leading to luminal hypoxemia and vein wall distension, which in turn may impair vasa venarum perfusion; the resulting mural endothelial hypoxia would lead to leukocyte invasion of the wall and remodelling of the media. We propose that varicose veins result if gross active hypertension stretches the valve ''rings'', rendering attached valves incompetent caudad to obstructed sites, replacing normal centripetal flow in perforating veins with centrifugal flow and over-distending those vessels. We also discuss how hypoxemia-related venous/capillary wall lesions may lead to accumulation of leukocytes, progressive blockage of capillary blood flow, lipodermosclerosis and skin ulceration.

  7. Chronic leg ulceration in homozygous sickle cell disease: the role of venous incompetence.

    PubMed

    Clare, Andrea; FitzHenley, Michael; Harris, June; Hambleton, Ian; Serjeant, Graham R

    2002-11-01

    Chronic leg ulceration is a common cause of morbidity in Jamaican patients with homozygous sickle cell (SS) disease. Ulcers heal more rapidly on bed rest and deteriorate on prolonged standing, suggesting a role of venous hypertension in their persistence. This hypothesis has been tested by Doppler detection of venous competence in SS patients and in matched controls with a normal haemoglobin (AA) genotype in the Jamaican Cohort Study. Venous incompetence was significantly more frequent in SS disease [137/183 (75%)] than in non-pregnant AA controls [53/137 (39%)]. Past or present ulceration occurred in 78 (43%) SS patients, with a highly significant association between leg ulceration and venous incompetence in the same leg (P < 0.001). Prominence and/or varicosities of the veins and spontaneous leg ulcers were more common among patients with multiple sites of incompetence. The association of venous incompetence with chronic leg ulceration identifies a further pathological mechanism contributing to the morbidity of SS disease. The cause of venous incompetence is unknown but the sluggish circulation associated with dependency, turbidity and impaired linear flow at venous valves, hypoxia-induced sickling, the rheological effects of high white cell counts, and activation of components of the coagulation system may all contribute. Venous hypertension in SS patients with leg ulceration suggests that firm elastic supportive dressings might promote healing of chronic leg ulcers.

  8. A 1D pulse wave propagation model of the hemodynamics of calf muscle pump function.

    PubMed

    Keijsers, J M T; Leguy, C A D; Huberts, W; Narracott, A J; Rittweger, J; van de Vosse, F N

    2015-07-01

    The calf muscle pump is a mechanism which increases venous return and thereby compensates for the fluid shift towards the lower body during standing. During a muscle contraction, the embedded deep veins collapse and venous return increases. In the subsequent relaxation phase, muscle perfusion increases due to increased perfusion pressure, as the proximal venous valves temporarily reduce the distal venous pressure (shielding). The superficial and deep veins are connected via perforators, which contain valves allowing flow in the superficial-to-deep direction. The aim of this study is to investigate and quantify the physiological mechanisms of the calf muscle pump, including the effect of venous valves, hydrostatic pressure, and the superficial venous system. Using a one-dimensional pulse wave propagation model, a muscle contraction is simulated by increasing the extravascular pressure in the deep venous segments. The hemodynamics are studied in three different configurations: a single artery-vein configuration with and without valves and a more detailed configuration including a superficial vein. Proximal venous valves increase effective venous return by 53% by preventing reflux. Furthermore, the proximal valves shielding function increases perfusion following contraction. Finally, the superficial system aids in maintaining the perfusion during the contraction phase and reduces the refilling time by 37%. © 2015 The Authors. International Journal for Numerical Methods in Biomedical Engineering published by John Wiley & Sons Ltd.

  9. Portal hemodynamic responses after oral intake of glucose in patients with cirrhosis.

    PubMed

    Tsunoda, T; Ohnishi, K; Tanaka, H

    1988-04-01

    Changes of portal, superior mesenteric, and splenic venous flows, and portohepatic gradient (portal vein pressure minus free hepatic vein pressure) after a meal were studied in patients with cirrhosis using the duplex ultrasonic Doppler flowmeter, and portal and hepatic vein catheterizations after ingestion of 227 ml of 33% glucose solution (300 kcal). As a control, changes of portal venous flow and portohepatic gradient after drinking 227 ml of water, were studied. Portal and superior mesenteric venous flows increased significantly at 30 min after glucose intake, and they returned gradually to the basal values, whereas no significant postprandial change occurred in splenic venous flow. The sum of superior mesenteric and splenic venous flows was greater than the estimated portal venous flow before glucose intake, and the difference widened during post-prandial mesenteric hyperemia, indicating an increase of blood flow into the portal-systemic shunts. After glucose intake, portohepatic gradient elevated immediately, in parallel with an increase of portal venous flow, and these changes persisted for the 30 min studied; however, no significant change occurred in these parameters after drinking water. 1) In patients with cirrhosis, hyperemia occurs in the intestine but not in the spleen after glucose intake, and 2) postprandial mesenteric hyperemia causes an increase of portal venous inflow, portal-systemic collateral flow, portal venous flow, and an elevation of portohepatic gradient.

  10. The role of noninvasive and invasive diagnostic imaging techniques for detection of extra-cranial venous system anomalies and developmental variants

    PubMed Central

    2013-01-01

    The extra-cranial venous system is complex and not well studied in comparison to the peripheral venous system. A newly proposed vascular condition, named chronic cerebrospinal venous insufficiency (CCSVI), described initially in patients with multiple sclerosis (MS) has triggered intense interest in better understanding of the role of extra-cranial venous anomalies and developmental variants. So far, there is no established diagnostic imaging modality, non-invasive or invasive, that can serve as the “gold standard” for detection of these venous anomalies. However, consensus guidelines and standardized imaging protocols are emerging. Most likely, a multimodal imaging approach will ultimately be the most comprehensive means for screening, diagnostic and monitoring purposes. Further research is needed to determine the spectrum of extra-cranial venous pathology and to compare the imaging findings with pathological examinations. The ability to define and reliably detect noninvasively these anomalies is an essential step toward establishing their incidence and prevalence. The role for these anomalies in causing significant hemodynamic consequences for the intra-cranial venous drainage in MS patients and other neurologic disorders, and in aging, remains unproven. PMID:23806142

  11. Intravascular thrombosis as a result of central venous access.

    PubMed

    Biernacka, Jadwiga; Nestorowicz, Andrzej; Wach, Małgorzata

    2002-01-01

    Central venous access represents one of the most basic therapeutic procedures in modern medicine. Unfortunately, numerous advantages that result from maintaining a central venous line are accompanied by some complications among which the venous thrombosis is the most significant clinically. The study was designed to assess frequency and natural history of this complication in the setting at a multi profile clinical hospital. Central venous cannulation was performed by a fully qualified anaesthesiologist in every case. There were 887 cannulations and only 5 patients with clinically significant venous thrombosis. The analysis of the collected data allowed us to state that the frequency of intravascular thrombosis is low, but this complication is often associated with extensive impairment of patency of the central veins. Full recanalization is not always achieved regardless of the treatment applied. Pulmonary embolism in the course of central venous thrombosis was diagnosed in one patient only and appeared as a multiple and fine X-ray infiltrates. It seems that in the presence of permanent or even life threatening complications of central venous thrombosis their risk should be minimized by frequent examination of the cannulation site and early initiation of antithrombotic treatment.

  12. Cross sectional survey of ultrasound use for central venous catheter insertion among resident physicians.

    PubMed

    Nomura, Jason T; Sierzenski, Paul R; Nace, Jason E; Bollinger, Melissa

    2008-07-01

    Use of ultrasound guidance for Central Venous Catheter insertion has been associated with decreased complications and increased success rates. Previous reports show low rates of use among physicians. Evaluation of the frequency of Ultrasound Guidance use for Central Venous Catheter insertion among residents at a teaching institution. A cross sectional electronic survey of resident physicians at a tertiary care teaching hospital was conducted to evaluate use of Ultrasound Guidance for Central Venous Catheterization. Assessment included self reported frequency of ultrasound guidance use, and volume of central venous catheter placement. Attitudes toward the use of ultrasound were assessed using Likert scales. There is a high rate. over 90%, of ultrasound guidance use for Internal Jugular central venous catheters among residents. The majority of residents use sterile real-time imaging with a single operator with a reported success rate greater then 80%. Resident use of ultrasound guidance for Internal Jugular central venous catheter insertion can be much higher than previously reported in the literature.

  13. Renal norepinephrine spillover during infusion of nonesterified fatty acids.

    PubMed

    Grekin, Roger J; Ngarmukos, Chardpra-Orn; Williams, David M; Supiano, Mark A

    2005-03-01

    Sympathetic activity and renal norepinephrine spillover are increased in obese individuals. We have reported that infusion of nonesterified fatty acids increases blood pressure in animals through stimulation of the sympathetic nervous system. In this study, we assessed the effect of increasing circulating nonesterified fatty acids on systemic and renal norepinephrine kinetics in healthy adults by infusing fat emulsion and heparin for 4 h. (3)H-norepinephrine was infused for 60 min before and again during the last hour of the fatty acid infusion to assess norepinephrine kinetics. Renal venous blood samples were obtained to calculate renal norepinephrine spillover. Nonesterified fatty acid levels increased threefold during the first hour and remained elevated throughout the study. Arterial and renal venous plasma norepinephrine levels fell by 15% and 20%, respectively, during the infusion (P < .05 for both). Kinetic analysis indicated that systemic release of norepinephrine into an extravascular compartment decreased from 11.6 +/- 1.1 to 10.0 +/- 1.3 nmol/min/m(2) (P = .067) and renal venous norepinephrine spillover decreased from 454 +/- 54 pmol/min (P = .055). These results indicate that nonesterified fatty acids do not have a direct stimulating effect on whole-body or renal sympathetic activity. It is possible that increased plasma levels of fatty acids serve as a signal to decrease sympathetic tone during the fasting state.

  14. Bilateral anomalous drainage of the posterior divisions of renal veins into the azygos venous system in a 20-year-old woman: a case report.

    PubMed

    Pallangyo, Pedro; Lyimo, Frederick; Nicholaus, Paulina; Masatu, Stephano; Janabi, Mohamed

    2016-12-03

    Renal vein anomalies are relatively infrequent and generally asymptomatic. Preoperative knowledge of such variants is, however, of paramount importance in several angiographic and surgical procedures including renal venography, renal vein sampling, spermatic embolization, and renal transplantation. Inadequate knowledge and failure to recognize such anatomic variations may lead to several operative hazards including hemorrhage, nephrectomy, and even death. We report a case of bilateral anomalous drainage of the posterior divisions of renal veins into the azygos venous system in a 20-year-old woman of African descent from Tanzania who presented to us with a 12-year history of recurrent anemia. She had anemia, a positive sickling test, and hemoglobin electrophoresis revealed a sickle cell trait (AS). She underwent computed tomography angiography of her chest and abdomen to rule out the presence of arteriovenous malformations. Aortography findings were normal but venography results revealed features of tortuously dilated azygos and hemiazygos veins each receiving blood from its respective posterior division of renal vein. Although venous anomalies are relatively infrequent and generally lack a clinical significance, a thorough understanding of embryologic development and its associated errors is of immense importance in equipping angiographers and surgeons to select appropriate interventional/operative techniques, anticipate risks, and prevent intervention-related complications.

  15. The role of interventional radiology in management of benign and malignant gynecologic diseases.

    PubMed

    Yu, Hyeon; Stavas, Joseph M

    2013-10-01

    This article focuses on the role of interventional radiology in the therapeutic and diagnostic management of benign and malignant gynecologic conditions. The subspecialty of interventional radiology utilizes minimally invasive advanced image-guided percutaneous techniques in gynecology that include central venous catheter placement, fluid aspiration, drainage catheter placement, tissue biopsy, inferior vena cava filter placement, and pelvic arterial embolization. Central venous catheters, such as ports, peripherally inserted central catheters, and tunneled catheters, are placed for intermediate to long-term intravenous chemotherapy or total parental nutrition or antibiotics. Patients with refractory malignant ascites or pleural effusion from seeding of advanced gynecologic cancers may benefit by percutaneous aspiration of fluid collections or placement of drainage catheters. Postoperative fluid collections including abscess, seroma, or lymphocele are managed by percutaneous drainage catheter insertion. Pelvic, peritoneal, or retroperitoneal masses can be sampled by image-guided percutaneous biopsy or aspiration of fluid to determine a pathologic diagnosis. Certain patients are at risk for deep venous thrombosis with pulmonary embolism and may benefit from an inferior vena cava filter. Patients with uncontrolled postoperative or postpartum bleeding can be effectively managed with emergent transarterial pelvic embolization. Each of the aforementioned interventions with indications, expected benefits, and complications is described including a published literature.

  16. Intraatrial baffle repair of anomalous systemic venous return without hepatic venous drainage in heterotaxy syndrome.

    PubMed

    Turkoz, Riza; Ayabakan, Canan; Vuran, Can; Omay, Oğuz

    2010-08-01

    A 7-month-old boy with heterotaxy syndrome had partial atrioventricular septal defect and interrupted inferior vena cava with hemiazygos continuation to a left superior vena cava. The left side of the common atrium receiving all the venous drainage was in connection with the left ventricle and the aorta. The small atrium and the proximity of the pulmonary and hepatic vein orifices precluded complete baffling. This report describes an intraatrial baffle repair of anomalous systemic venous return without hepatic venous drainage. This resulted in good oxygenation postoperatively, with oxygen saturation ranging from 93% to 98%.

  17. Venous thrombosis and stenosis after peripherally inserted central catheter placement in children.

    PubMed

    Shin, H Stella; Towbin, Alexander J; Zhang, Bin; Johnson, Neil D; Goldstein, Stuart L

    2017-11-01

    Peripherally inserted central catheters (PICCs) can lead to development of venous thrombosis and/or stenosis. The presence of venous thrombosis and/or stenosis may preclude children with chronic medical conditions from receiving lifesaving therapies, from hemodialysis in end-stage renal disease to total parenteral nutrition in short bowel syndrome. Several adult studies have found an association between PICCs and venous thrombosis and/or stenosis, but none has evaluated for this association in children. To determine the incidence of venous thrombosis and/or stenosis after PICC placement and identify factors that increase the risk of venous thrombosis and/or stenosis after PICC placement in children. We conducted a retrospective review of children ages 1-18 years with a PICC placed between January 2010 and July 2013 at our center, and included those who had at least one vascular imaging study of the ipsilateral extremity (Doppler ultrasound, venogram or MR angiogram) after PICC placement. Logistic regression was applied to determine risk factors for development of venous thrombosis and/or stenosis. One thousand, one hundred and ten upper extremity PICCs were placed, with 703 PICCs in the right and 407 PICCs in the left. Eight hundred fifty-one imaging studies (609 Doppler ultrasounds, 193 contrast venograms and 49 MR angiograms) were performed in 376 patients. The incidence of venous thrombosis and/or stenosis in the imaged cohort was 26.3%. PICC laterality, insertion site, duration, patient height to PICC diameter ratio, and number of PICCs per patient were not associated with development of venous thrombosis and/or stenosis. Additionally, primary diagnosis and symptoms at the time of imaging did not predict findings of venous thrombosis and/or stenosis. However, patients exposed to non-PICC central venous catheters (CVC) were more likely to develop venous thrombosis and/or stenosis (odds ratio 1.95, 1.10-3.45). More than a quarter of the vascular imaging studies performed in this study cohort showed previously unknown venous thrombosis and/or stenosis, irrespective of PICC laterality, insertion site, duration and size and the number of PICCs. A history of CVC was associated with a nearly two-fold increase in risk of venous thrombosis and/or stenosis after PICC placement. We suggest that PICCs and CVCs should be placed judiciously in all children, but especially in those with lifelong medical conditions who are more likely to incur direct consequences from limited vascular access.

  18. US Army Institute of Surgical Research Annual Research Progress Report for Fiscal Year 1987.

    DTIC Science & Technology

    1987-10-01

    oases, respiratory rate, chest roentgenograms), cardiovascular (blood pressure, central venous pressure, cardiac output), and renal (urine output, urine...Monitoring includes the precordial and/or esophageal stethoscope, peripheral pulse, blood pressure, central venous pressure, Swan-Ganz catheter... central venous , peripheral venous , and Swan-Ganz (7F, American Edward Laboratories, Irvine CA) catheters and an esophageal balloon were inserted. After a 2

  19. Advanced Technologies in Trauma Critical Care Management

    DTIC Science & Technology

    2012-01-01

    CVL, central venous line; DVT, deep venous thrombosis; FAST, focused assessment with sonography for trauma; IVC, inferior vena cava; PIV, peripheral...either for a 1-time view of the target vein or in real time using a 1- or 2-person technique. Recently, ultrasound-guided subclavian central venous ...technologies such as bedside echocardiography, central venous pressure monitoring, and cardiac electrical velocimetry. These limitations aside, it is

  20. Venous trauma in the Lebanon War--2006.

    PubMed

    Nitecki, Samy S; Karram, Tony; Hoffman, Aaron; Bass, Arie

    2007-10-01

    Reports on venous trauma are relatively sparse. Severe venous trauma is manifested by hemorrhage, not ischemia. Bleeding may be internal or external and rarely may lead to hypovolemic shock. Repair of major extremity veins has been a subject of controversy and the current teaching is to avoid venous repair in an unstable or multi-trauma patient. The aim of the current paper is to present our recent experience in major venous trauma during the Lebanon conflict, means of diagnosis and treatment in a level I trauma center. All cases of major venous trauma, either isolated or combined with arterial injury, admitted to the emergency room during the 33-day conflict were reviewed. Out of 511 wounded soldiers and civilians who were admitted to our service over this period, 12 (2.3%) sustained a penetrating venous injury either isolated (5) or combined with arterial injury (7). All injuries were secondary to high velocity penetrating missiles or from multiple pellets stored in long-range missiles. All injuries were accompanied by additional insult to soft tissue, bone and viscera. The mean injury severity score was 15. Severe external bleeding was the presenting symptom in three cases of isolated venous injury (jugular, popliteal and femoral). The diagnosis of a major venous injury was made by a CTA scan in five cases, angiography in one and during surgical exploration in six cases. All injured veins were repaired: three by venous interposition grafts, four by end to end anastomosis, three by lateral suture and two by endovascular techniques. None of the injuries was treated by ligation of a major named vein. Immediate postoperative course was uneventful in all patients and the 30-day follow-up (by clinical assessment and duplex scan) has demonstrated a patent repair with no evidence of thrombosis. Without contradicting the wisdom of ligating major veins in the setup of multi-trauma or an unstable patient, our experience indicates that a routine repair of venous trauma can be safely and effectively performed in young patients. Postoperative course is not compromised and late sequelae of venous interruption may be prevented.

  1. Placental Glucose Transfer: A Human In Vivo Study

    PubMed Central

    Holme, Ane M.; Roland, Marie Cecilie P.; Lorentzen, Bjørg; Michelsen, Trond M.; Henriksen, Tore

    2015-01-01

    Objectives The placental transfer of nutrients is influenced by maternal metabolic state, placenta function and fetal demands. Human in vivo studies of this interplay are scarce and challenging. We aimed to establish a method to study placental nutrient transfer in humans. Focusing on glucose, we tested a hypothesis that maternal glucose concentrations and uteroplacental arterio-venous difference (reflecting maternal supply) determines the fetal venous-arterial glucose difference (reflecting fetal consumption). Methods Cross-sectional in vivo study of 40 healthy women with uncomplicated term pregnancies undergoing planned caesarean section. Glucose and insulin were measured in plasma from maternal and fetal sides of the placenta, at the incoming (radial artery and umbilical vein) and outgoing vessels (uterine vein and umbilical artery). Results There were significant mean (SD) uteroplacental arterio-venous 0.29 (0.23) mmol/L and fetal venous-arterial 0.38 (0.31) mmol/L glucose differences. The transplacental maternal-fetal glucose gradient was 1.22 (0.42) mmol/L. The maternal arterial glucose concentration was correlated to the fetal venous glucose concentration (r = 0.86, p<0.001), but not to the fetal venous-arterial glucose difference. The uteroplacental arterio-venous glucose difference was neither correlated to the level of glucose in the umbilical vein, nor fetal venous-arterial glucose difference. The maternal-fetal gradient was correlated to fetal venous-arterial glucose difference (r = 0.8, p<0.001) and the glucose concentration in the umbilical artery (r = −0.45, p = 0.004). Glucose and insulin concentrations were correlated in the mother (r = 0.52, p = 0.001), but not significantly in the fetus. We found no significant correlation between maternal and fetal insulin values. Conclusions We did not find a relation between indicators of maternal glucose supply and the fetal venous-arterial glucose difference. Our findings indicate that the maternal-fetal glucose gradient is significantly influenced by the fetal venous-arterial difference and not merely dependent on maternal glucose concentration or the arterio-venous difference on the maternal side of the placenta. PMID:25680194

  2. Upper extremity deep venous thrombosis after port insertion: What are the risk factors?

    PubMed

    Tabatabaie, Omidreza; Kasumova, Gyulnara G; Kent, Tara S; Eskander, Mariam F; Fadayomi, Ayotunde B; Ng, Sing Chau; Critchlow, Jonathan F; Tawa, Nicholas E; Tseng, Jennifer F

    2017-08-01

    Totally implantable venous access devices (ports) are widely used, especially for cancer chemotherapy. Although their use has been associated with upper extremity deep venous thrombosis, the risk factors of upper extremity deep venous thrombosis in patients with a port are not studied adequately. The Healthcare Cost and Utilization Project's Florida State Ambulatory Surgery and Services Database was queried between 2007 and 2011 for patients who underwent outpatient port insertion, identified by Current Procedural Terminology code. Patients were followed in the State Ambulatory Surgery and Services Database, State Inpatient Database, and State Emergency Department Database for upper extremity deep venous thrombosis occurrence. The cohort was divided into a test cohort and a validation cohort based on the year of port placement. A multivariable logistic regression model was developed to identify risk factors for upper extremity deep venous thrombosis in patients with a port. The model then was tested on the validation cohort. Of the 51,049 patients in the derivation cohort, 926 (1.81%) developed an upper extremity deep venous thrombosis. On multivariate analysis, independently significant predictors of upper extremity deep venous thrombosis included age <65 years (odds ratio = 1.22), Elixhauser score of 1 to 2 compared with zero (odds ratio = 1.17), end-stage renal disease (versus no kidney disease; odds ratio = 2.63), history of any deep venous thrombosis (odds ratio = 1.77), all-cause 30-day revisit (odds ratio = 2.36), African American race (versus white; odds ratio = 1.86), and other nonwhite races (odds ratio = 1.35). Additionally, compared with genitourinary malignancies, patients with gastrointestinal (odds ratio = 1.55), metastatic (odds ratio = 1.76), and lung cancers (odds ratio = 1.68) had greater risks of developing an upper extremity deep venous thrombosis. This study identified major risk factors of upper extremity deep venous thrombosis. Further studies are needed to evaluate the appropriateness of thromboprophylaxis in patients at greater risk of upper extremity deep venous thrombosis. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. [The unnecessary application of central venous catheterization in surgical patients].

    PubMed

    Uemura, Keiko; Inoue, Satoki; Kawaguchi, Masahiko

    2018-04-06

    Perioperative physicians occasionally encounter situations where central venous catheters placed preoperatively turn out to be unnecessary. The purpose of this retrospective study is to identify the unnecessary application of central venous catheter placement and determine the factors associated with the unnecessary application of central venous catheter placement. Using data from institutional perioperative central venous catheter surveillance, we analysed data from 1,141 patients who underwent central venous catheter placement. We reviewed the central venous catheter registry and medical charts and allocated registered patients into those with the proper or with unnecessary application of central venous catheter according to standard indications. Multivariate analysis was used to identify factors associated with the unnecessary application of central venous catheter placement. In 107 patients, representing 9.38% of the overall population, we identified the unnecessary application of central venous catheter placement. Multivariate analysis identified emergencies at night or on holidays (odds ratio [OR] 2.109, 95% confidence interval [95% CI] 1.021-4.359), low surgical risk (OR=1.729, 95% CI 1.038-2.881), short duration of anesthesia (OR=0.961/10min increase, 95% CI 0.945-0.979), and postoperative care outside of the intensive care unit (OR=2.197, 95% CI 1.402-3.441) all to be independently associated with the unnecessary application of catheterization. Complications related to central venous catheter placement when the procedure consequently turned out to be unnecessary were frequently observed (9/107) compared with when the procedure was necessary (40/1034) (p=0.032, OR=2.282, 95% CI 1.076-4.842). However, the subsequent multivariate logistic model did not hold this significant difference (p=0.0536, OR=2.115, 95% CI 0.988-4.526). More careful consideration for the application of central venous catheter is required in cases of emergency surgery at night or on holidays, during low risk surgery, with a short duration of anesthesia, or in cases that do not require postoperative intensive care. Copyright © 2018 Sociedade Brasileira de Anestesiologia. Publicado por Elsevier Editora Ltda. All rights reserved.

  4. Hyperspectral venous image quality assessment for optimum illumination range selection based on skin tone characteristics

    PubMed Central

    2014-01-01

    Background Subcutaneous veins localization is usually performed manually by medical staff to find suitable vein to insert catheter for medication delivery or blood sample function. The rule of thumb is to find large and straight enough vein for the medication to flow inside of the selected blood vessel without any obstruction. The problem of peripheral difficult venous access arises when patient’s veins are not visible due to any reason like dark skin tone, presence of hair, high body fat or dehydrated condition, etc. Methods To enhance the visibility of veins, near infrared imaging systems is used to assist medical staff in veins localization process. Optimum illumination is crucial to obtain a better image contrast and quality, taking into consideration the limited power and space on portable imaging systems. In this work a hyperspectral image quality assessment is done to get the optimum range of illumination for venous imaging system. A database of hyperspectral images from 80 subjects has been created and subjects were divided in to four different classes on the basis of their skin tone. In this paper the results of hyper spectral image analyses are presented in function of the skin tone of patients. For each patient, four mean images were constructed by taking mean with a spectral span of 50 nm within near infrared range, i.e. 750–950 nm. Statistical quality measures were used to analyse these images. Conclusion It is concluded that the wavelength range of 800 to 850 nm serve as the optimum illumination range to get best near infrared venous image quality for each type of skin tone. PMID:25087016

  5. Preliminary results after upper cervical chiropractic care in patients with chronic cerebro-spinal venous insufficiency and multiple sclerosis.

    PubMed

    Mandolesi, Sandro; Marceca, Giuseppe; Moser, Jon; Niglio, Tarcisio; d'Alessandro, Aldo; Ciccone, Matteo Marco; Zito, Annapaola; Mandolesi, Dimitri; d'Alessandro, Alessandro; Fedele, Francesco

    2015-01-01

    The aim of the study is to evaluate the clinical and X-ray results of the Upper Cervical Chiropractic care through the specific adjustments (corrections) of C1-C2 on patients with chronic venous cerebral-spinal insufficiency (CCSVI) and multiple sclerosis (MS). We studied a sample of 77 patients before and after the Upper Cervical Chiropractic care, and we analyzed: A) The change of the X-ray parameters; B) The clinical results using a new set of questions. The protocol of the C1- C2 upper Cervical Chiropractic treatment, specific for these patients, lasts four months. From a haemodynamic point of view we divided the patients in 3 types: Type 1 - purely vascular with intravenous alterations; Type 2 - "mechanical" with of external venous compressions; Type 3 - mixed. We found an improvement in all kinds of subluxations after the treatment with respect to the pre-treatment X-ray evaluation, with a significant statistical difference. The differences between the clinical symptoms before and after the specific treatment of C1-C2 are statistically significant with p<0.001 according to the CHI-Square test revised by Yates. The preliminary X-ray and clinical improvements of the Upper Cervical Chiropractic corrections on C1- C2 on these patients with CCSVI and MS encourage us to continue with our studies. We believe that the Upper Cervical correction on C1-C2 could be the main non-invasive treatment of the CCSVI mechanical type in patients with MS. Further studies are required to evaluate the correlation between the Upper Cervical Chiropractic correction on C1-C2 on the cerebral venous drainage and the cerebro-spinal fluid.

  6. Comparison between B·R·A·H·M·S PCT direct, a new sensitive point-of-care testing device for rapid quantification of procalcitonin in emergency department patients and established reference methods - a prospective multinational trial.

    PubMed

    Kutz, Alexander; Hausfater, Pierre; Oppert, Michael; Alan, Murat; Grolimund, Eva; Gast, Claire; Alonso, Christine; Wissmann, Christoph; Kuehn, Christian; Bernard, Maguy; Huber, Andreas; Mueller, Beat; Schuetz, Philipp

    2016-04-01

    Procalcitonin (PCT) is increasingly being used for the diagnostic and prognostic work up of patients with suspected infections in the emergency department (ED). Recently, B·R·A·H·M·S PCT direct, the first high sensitive point-of-care test (POCT), has been developed for fast PCT measurement on capillary or venous blood samples. This is a prospective, international comparison study conducted in three European EDs. Consecutive patients with suspicion of bacterial infection were included. Duplicate determination of PCT was performed in capillary (fingertip) and venous whole blood (EDTA), and compared to the reference method. The diagnostic accuracy was evaluated by correlation and concordance analyses. Three hundred and three patients were included over a 6-month period (60.4% male, median age 65.2 years). The correlation between capillary or venous whole blood and the reference method was excellent: r2=0.96 and 0.97, sensitivity 88.1% and 93.0%, specificity 96.5% and 96.8%, concordance 93% and 95%, respectively at a 0.25 μg/L threshold. No significant bias was observed (-0.04 and -0.02 for capillary and venous whole blood) although there were 6.8% and 5.1% outliers, respectively. B·R·A·H·M·S PCT direct had a shorter time to result as compared to the reference method (25 vs. 144 min, difference 119 min, 95% CI 110-134 min, p<0.0001). This study found a high diagnostic accuracy and a faster time to result of B·R·A·H·M·S PCT direct in the ED setting, allowing shortening time to therapy and a more wide-spread use of PCT.

  7. Treatment and follow-up of venous thrombosis in the neonatal intensive care unit: A retrospective study

    PubMed Central

    Bohnhoff, James C.; DiSilvio, Stefanie A.; Aneja, Rajesh K.; Shenk, Jennifer R.; Domnina, Yuliya A.; Brozanski, Beverly S.; Good, Misty

    2016-01-01

    Objective The critically ill, premature patients of neonatal intensive care units are susceptible to venous thrombosis, an adverse event associated with short- and long-term morbidity. Venous thrombosis is frequently treated with low molecular weight heparins (LMWH) such as enoxaparin, but optimal dosing of LMWH must balance the morbidity of venous thrombosis with the potential adverse affects of anticoagulation. The optimal dosing of enoxaparin for premature infants is unclear. The objective of this study was to describe enoxaparin therapy and follow-up in critically ill neonates diagnosed with venous thrombosis. Study Design Retrospective medical record review in the neonatal intensive care unit (NICU) in a single tertiary care institution. Infants with venous thrombosis diagnosed in the NICU were identified using pre-existing quality improvement lists and medical records. Results Twenty-six infants with 30 venous thromboses were identified with a median gestational age of 31 weeks at birth. Eighteen (69%) infants received enoxaparin for venous thrombosis during their hospitalization, beginning with a median dose of 1.5 mg/kg every 12h. This dose was increased to a median 2.1 mg/kg every 12h to achieve target anti-factor Xa levels. The target dose was significantly higher in patients with a postmenstrual age less than 37 weeks. Enoxaparin treatment was documented after discharge in 12 patients, continuing for a median of 99 days. Four patients died during hospitalization and their deaths were not attributable to venous thrombosis or anticoagulation complication. Follow-up documentation between 6 and 24 months after venous thrombosis diagnosis revealed no major morbidity of venous thrombosis or enoxaparin therapy. Conclusions Our data reinforces the relative safety and necessity of enoxaparin doses above 1.5 mg/kg per 12 hours in most neonates. This was particularly true for infants at lower postmenstrual age. PMID:27906197

  8. Vacuum-assisted venous return reduces blood usage.

    PubMed

    Banbury, Michael K; White, Jennifer A; Blackstone, Eugene H; Cosgrove, Delos M

    2003-09-01

    To determine whether vacuum-assisted venous return has clinical advantages over conventional gravity drainage apart from allowing the use of smaller cannulas and shorter tubing. A total of 150 valve operations were performed at our institution between February and July 1999 using vacuum-assisted venous return with small venous cannulas connected to short tubing. These were compared with (1) 83 valve operations performed between April 1997 and January 1998 using the initial version of vacuum-assisted venous return, and (2) 124 valve operations performed between January and April of 1997 using conventional gravity drainage. Priming volume, hematocrit value, red blood cell usage, and total blood product usage were compared multivariably. These comparisons were covariate and propensity adjusted for dissimilarities between the groups and confirmed by propensity-matched pairs analysis. Priming volume was 1.4 +/- 0.4 L for small-cannula vacuum-assisted venous return, 1.7 +/- 0.4 L for initial vacuum-assisted venous return, and 2.0 +/- 0.4 L for gravity drainage (P <.0001). Smaller priming resulted in higher hematocrit values both at the beginning of cardiopulmonary bypass (27% +/- 5% compared with 26% +/- 4% and 25% +/- 4%, respectively, P <.0001) and at the end (30% +/- 4% compared with 28% +/- 4% and 27% +/- 4%, respectively, P <.0001). Red cell transfusions were used in 17% of the patients having small-cannula vacuum-assisted venous return, 27% of the initial patients having vacuum-assisted venous return, and 37% of the patients having gravity drainage (P =.001); total blood product usage was 19%, 27%, and 39%, respectively (P =.002). Although ministernotomy also was associated with reduced blood product usage (P <.004), propensity matching on type of sternotomy confirmed the association of vacuum-assisted venous return with lowered blood product usage. Vacuum-assisted venous return results in (1) higher hematocrit values during cardiopulmonary bypass and (2) decreased red cell and total blood product usage.

  9. Ultrasound as a Screening Tool for Central Venous Catheter Positioning and Exclusion of Pneumothorax.

    PubMed

    Amir, Rabia; Knio, Ziyad O; Mahmood, Feroze; Oren-Grinberg, Achikam; Leibowitz, Akiva; Bose, Ruma; Shaefi, Shahzad; Mitchell, John D; Ahmed, Muneeb; Bardia, Amit; Talmor, Daniel; Matyal, Robina

    2017-07-01

    Although real-time ultrasound guidance during central venous catheter insertion has become a standard of care, postinsertion chest radiograph remains the gold standard to confirm central venous catheter tip position and rule out associated lung complications like pneumothorax. We hypothesize that a combination of transthoracic echocardiography and lung ultrasound is noninferior to chest radiograph when used to accurately assess central venous catheter positioning and screen for pneumothorax. All operating rooms and surgical and trauma ICUs at the institution. Single-center, prospective noninferiority study. Patients receiving ultrasound-guided subclavian or internal jugular central venous catheters. During ultrasound-guided central venous catheter placement, correct positioning of central venous catheter was accomplished by real-time visualization of the guide wire and positive right atrial swirl sign using the subcostal four-chamber view. After insertion, pneumothorax was ruled out by the presence of lung sliding and seashore sign on M-mode. Data analysis was done for 137 patients. Chest radiograph ruled out pneumothorax in 137 of 137 patients (100%). Lung ultrasound was performed in 123 of 137 patients and successfully screened for pneumothorax in 123 of 123 (100%). Chest radiograph approximated accurate catheter tip position in 136 of 137 patients (99.3%). Adequate subcostal four-chamber views could not be obtained in 13 patients. Accurate positioning of central venous catheter with ultrasound was then confirmed in 121 of 124 patients (97.6%) as described previously. Transthoracic echocardiography and lung ultrasound are noninferior to chest x-ray for screening of pneumothorax and accurate central venous catheter positioning. Thus, the point of care use of ultrasound can reduce central venous catheter insertion to use time, exposure to radiation, and improve patient safety.

  10. Risk of venous thromboembolism in women with polycystic ovary syndrome: a population-based matched cohort analysis.

    PubMed

    Bird, Steven T; Hartzema, Abraham G; Brophy, James M; Etminan, Mahyar; Delaney, Joseph A C

    2013-02-05

    There is an increased risk of venous thromboembolism among women taking oral contraceptives. However, whether there is an additional risk among women with polycystic ovary syndrome (PCOS) is unknown. We developed a population-based cohort from the IMS LifeLink Health Plan Claims Database, which includes managed care organizations in the United States. Women aged 18-46 years taking combined oral contraceptives and who had a claim for PCOS (n = 43 506) were matched, based on a propensity score, to control women (n = 43 506) taking oral contraceptives. Venous thromboembolism was defined using administrative coding and use of anticoagulation. We used Cox proportional hazards models to assess the relative risk (RR) of venous thromboembolism among users of combined oral contraceptives with and without PCOS. The incidence of venous thromboembolism among women with PCOS was 23.7/10 000 person-years, while that for matched controls was 10.9/10 000 person-years. Women with PCOS taking combined oral contraceptives had an RR for venous thromboembolism of 2.14 (95% confidence interval [CI] 1.41-3.24) compared with other contraceptive users. The incidence of venous thromboembolism was 6.3/10 000 person-years among women with PCOS not taking oral contraceptives; the incidence was 4.1/10 000 person-years among matched controls. The RR of venous thromboembolism among women with PCOS not taking oral contraceptives was 1.55 (95% CI 1.10-2.19). We found a 2-fold increased risk of venous thromboembolism among women with PCOS who were taking combined oral contraceptives and a 1.5-fold increased risk among women with PCOS not taking oral contraceptives. Physicians should consider the increased risk of venous thromboembolism when prescribing contraceptive therapy to women with PCOS.

  11. Venous and Arterial Thromboses: Two Sides of the Same Coin?

    PubMed

    Lippi, Giuseppe; Favaloro, Emmanuel J

    2018-04-01

    Arterial and venous thromboses are sustained by development of intraluminal thrombi, respectively, within the venous and arterial systems. The composition and structure of arterial and venous thrombi have been historically considered as being very different. Arterial thrombi (conventionally defined as "white") have been traditionally proposed to be composed mainly of fibrin and platelet aggregates, whilst venous thrombi (conventionally defined as "red") have been proposed as mostly being enriched in fibrin and erythrocytes. This archaic dichotomy seems ever more questionable, since it barely reflects the pathophysiology of thrombus formation in vivo. Both types of thrombi are actually composed of a complex fibrin network but, importantly, also contain essentially the same blood-borne cells (i.e., red blood cells, leukocytes, and platelets), and it is only the relative content of these individual elements that differ between venous and arterial clots or, otherwise, between thrombi generated under different conditions of blood flow and shear stress. Convincing evidence now suggests that either white or red intracoronary thrombi may be present in patients with myocardial infarction and, even more importantly, red thrombi may be more prone to distal embolization during percutaneous coronary intervention than those with lower content of erythrocytes. Conversely, it is now accepted that components traditionally considered to be involved "only" in arterial thrombosis are also represented in venous thrombosis. Thus, platelets comprise important components of venous clots, although they may be present in lower amounts here than in arterial thrombi, and von Willebrand factor is also represented in both arterial and venous thrombi. Of importance, such evidence thus supports the concept that adjunctive treatment normally associated to prevention of arterial thrombosis (e.g., aspirin) may have a role also in prevention and treatment of venous thrombosis. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  12. Association study of methylenetetrahydrofolate reductase C677T mutation with cerebral venous thrombosis in an Iranian population.

    PubMed

    Ghaznavi, Habib; Soheili, Zahra; Samiei, Shahram; Soltanpour, Mohammad S

    2015-12-01

    There are limited data on the role of methylenetetrahydrofolate reductase C677T polymorphism and hyperhomocysteinemia as risk factors for cerebral venous thrombosis in Iranian population. We examined a possible association between fasting plasma homocysteine levels, methylenetetrahydrofolate reductase C677T polymorphism, and cerebral venous thrombosis in 50 patients with a diagnosis of cerebral venous thrombosis (20-63 years old) and 75 healthy controls (18-65 years old). Genotyping of the methylenetetrahydrofolate reductase C677T gene polymorphism was performed by PCR-restriction fragment length polymorphism analysis, and homocysteine levels were measured by enzyme immunoassay. Fasting plasma homocysteine levels were significantly higher in cerebral venous thrombosis patients than in controls (P = 0.015). Moreover, plasma homocysteine levels were significantly higher in methylenetetrahydrofolate reductase 677TT genotype compared to 677CT and 677CC genotypes in both cerebral venous thrombosis patients (P = 0.01) and controls (P = 0.03). Neither 677CT heterozygote genotype [odds ratio (OR) 1.35, 95% confidence interval (CI) 0.64-2.84, P = 0.556] nor 677TT homozygote genotype (OR 1.73, 95% CI 0.32-9.21, P = 0.833) was significantly associated with cerebral venous thrombosis. Additionally, no significant differences in the frequency of 677T allele between cerebral venous thrombosis patients and controls were identified (OR 1.31, 95% CI 0.69-2.50, P = 0.512). In conclusion, our study demonstrated that elevated plasma homocysteine levels are significant risk factors for cerebral venous thrombosis. Also, methylenetetrahydrofolate reductase 677TT genotype is not linked with cerebral venous thrombosis, but is a determinant of elevated plasma homocysteine levels.

  13. A randomized controlled trial of a mixed Kinesio taping-compression technique on venous symptoms, pain, peripheral venous flow, clinical severity and overall health status in postmenopausal women with chronic venous insufficiency.

    PubMed

    Aguilar-Ferrándiz, M Encarnación; Castro-Sánchez, Adelaida María; Matarán-Peñarrocha, Guillermo A; Guisado-Barrilao, Rafael; García-Ríos, M Carmen; Moreno-Lorenzo, Carmen

    2014-01-01

    To investigate the effect of a mixed Kinesio taping treatment in women with chronic venous insufficiency. A double-blinded randomized clinical trial. Clinical setting. One hundred and twenty postmenopausal women with mild-moderate chronic venous insufficiency were randomly assigned to an experimental group receiving standardized Kinesio taping treatment for gastrocnemius muscle enhancement and ankle functional correction, or to a placebo control group for simulated Kinesio taping. MAIN OUTCOMES VARIABLES: Venous symptoms, pain, photoplethysmographic measurements, bioelectrical impedance, temperature, severity and overall health were recorded at baseline and after four weeks of treatment. The 2 × 2 mixed model ANCOVA with repeated measurements showed statistically significant group * time interaction for heaviness (F = 22.99, p = 0.002), claudication (F = 8.57, p = 0.004), swelling (F = 22.58, p = 0.001), muscle cramps (F = 7.14, p = 0.008), venous refill time (right: F = 9.45, p = 0.023; left: F = 14.86, p = 0.001), venous pump function (right: F = 35.55, p = 0.004; left: F = 17.39 p = 0.001), extracellular water (right: F = 35.55, p = 0.004; left: F = 23.84, p = 0.001), severity (F = 18.47, p = 0.001), physical function (F = 9.15, p = 0.003) and body pain (F = 3.36, p = 0.043). Both groups reported significant reduction in pain. Mixed Kinesio taping-compression therapy improves symptoms, peripheral venous flow and severity and slightly increases overall health status in females with mild chronic venous insufficiency. Kinesio taping may have a placebo effect on pain.

  14. Risk factors for venous port migration in a single institute in Taiwan

    PubMed Central

    2014-01-01

    Background An implantable port device provides an easily accessible central route for long-term chemotherapy. Venous catheter migration is one of the rare complications of venous port implantation. It can lead to side effects such as pain in the neck, shoulder, or ear, venous thrombosis, and even life-threatening neurologic problems. To date, there are few published studies that discuss such complications. Methods This retrospective study of venous port implantation in a single center, a Taiwan hospital, was conducted from January 2011 to March 2013. Venous port migration was recorded along with demographic and characteristics of the patients. Results Of 298 patients with an implantable import device, venous port migration had occurred in seven, an incidence rate of 2.3%. All seven were male and had received the Bard port Fr 6.6 which had smaller size than TYCO port Fr 7.5 and is made of silicon. Significantly, migration occurred in male patients (P = 0.0006) and in those with lung cancer (P = 0.004). Multivariable logistic regression analysis revealed that lung cancer was a significant risk factor for port migration (odds ratio: 11.59; P = 0.0059). The migration rate of the Bard port Fr 6.6 was 6.7%. The median time between initial venous port implantation and port migration was 35.4 days (range, 7 to 135 days) and 71.4% (5/7) of patients had port migration within 30 days after initial port implantation. Conclusions Male sex and lung cancer are risk factors for venous port migration. The type of venous port is also an important risk factor. PMID:24423026

  15. Safety and Efficacy Study of Sirolimus in Complicated Vascular Anomalies

    ClinicalTrials.gov

    2015-02-03

    Kaposiform Hemangioendotheliomas; Tufted Angioma; Capillary Venous Lymphatic Malformation; Venous Lymphatic Malformation; Microcystic Lymphatic Malformation; Mucocutaneous Lymphangiomatosis and Thrombocytopenia; Capillary Lymphatic Arterial Venous Malformations; PTEN Overgrowth Syndrome With Vascular Anomaly; Lymphangiectasia Syndromes

  16. Venous return curves obtained from graded series of valsalva maneuvers

    NASA Technical Reports Server (NTRS)

    Mastenbrook, S. M., Jr.

    1974-01-01

    The effects were studied of a graded series of valsalva-like maneuvers on the venous return, which was measured transcutaneously in the jugular vein of an anesthetized dog, with the animal serving as its own control. At each of five different levels of central venous pressure, the airway pressure which just stopped venous return during each series of maneuvers was determined. It was found that this end-point airway pressure is not a good estimator of the animal's resting central venous pressure prior to the simulated valsalva maneuver. It was further found that the measured change in right atrial pressure during a valsalva maneuver is less than the change in airway pressure during the same maneuver, instead of being equal, as had been expected. Relative venous return curves were constructed from the data obtained during the graded series of valsalva maneuvers.

  17. Does the preference of peripheral versus central venous access in peripheral blood stem cell collection/yield change stem cell kinetics in autologous stem cell transplantation?

    PubMed

    Dogu, Mehmet Hilmi; Kaya, Ali Hakan; Berber, Ilhami; Sari, İsmail; Tekgündüz, Emre; Erkurt, Mehmet Ali; Iskender, Dicle; Kayıkçı, Ömur; Kuku, Irfan; Kaya, Emin; Keskin, Ali; Altuntaş, Fevzi

    2016-02-01

    Central venous access is often used during apheresis procedure in stem cell collection. The aim of the present study was to evaluate whether central or peripheral venous access has an effect on stem cell yield and the kinetics of the procedure and the product in patients undergoing ASCT after high dose therapy. A total of 327 patients were retrospectively reviewed. The use of peripheral venous access for stem cell yield was significantly more frequent in males compared to females (p = 0.005). Total volume of the product was significantly lower in central venous access group (p = 0.046). As being a less invasive procedure, peripheral venous access can be used for stem cell yield in eligible selected patients. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Cannulation for veno-venous extracorporeal membrane oxygenation

    PubMed Central

    2018-01-01

    Extracorporeal membrane oxygenation (ECMO) is described as a modified, smaller cardiopulmonary bypass circuit. The veno-venous (VV) ECMO circuit drains venous blood, oxygenate the blood, and pump the blood back into the same venous compartment. Draining and reinfusing in the same compartment means there are a risk of recirculation. The draining position within the venous system, ECMO pump flow, return flow position within the venous system and the patients cardiac output (CO) all have an impact on recirculation. Using two single lumen cannulas or one dual lumen cannula, but also the design of the venous cannula, can have an impact on where within the venous system the cannula is draining blood and will affect the efficiency of the ECMO circuit. VV ECMO can be performed with different cannulation strategies. The use of two single lumen cannulas draining in inferior vena cava (IVC) and reinfusing in superior vena cava (SVC) or draining in SVC and reinfusing in IVC, or one dual lumen cannula inserted in right jugular vein is all possible cannulation strategies. Independent of cannulation strategy there will be a risk of recirculation. Efficiency can be reasonable in either strategy if the cannulas are carefully positioned and monitored during the dynamic procedure of pulmonary disease. The disadvantage draining from IVC only occurs when there is a need for converting from VV to veno-arterial (VA) ECMO, reinfusing in the femoral artery. Then draining from SVC is the most efficient strategy, draining low saturated venous blood, and also means low risk of dual circulation. PMID:29732177

  19. Noninvasive glucose sensing by transcutaneous Raman spectroscopy

    NASA Astrophysics Data System (ADS)

    Shih, Wei-Chuan; Bechtel, Kate L.; Rebec, Mihailo V.

    2015-05-01

    We present the development of a transcutaneous Raman spectroscopy system and analysis algorithm for noninvasive glucose sensing. The instrument and algorithm were tested in a preclinical study in which a dog model was used. To achieve a robust glucose test system, the blood levels were clamped for periods of up to 45 min. Glucose clamping and rise/fall patterns have been achieved by injecting glucose and insulin into the ear veins of the dog. Venous blood samples were drawn every 5 min and a plasma glucose concentration was obtained and used to maintain the clamps, to build the calibration model, and to evaluate the performance of the system. We evaluated the utility of the simultaneously acquired Raman spectra to be used to determine the plasma glucose values during the 8-h experiment. We obtained prediction errors in the range of ˜1.5-2 mM. These were in-line with a best-case theoretical estimate considering the limitations of the signal-to-noise ratio estimates. As expected, the transition regions of the clamp study produced larger predictive errors than the stable regions. This is related to the divergence of the interstitial fluid (ISF) and plasma glucose values during those periods. Two key contributors to error beside the ISF/plasma difference were photobleaching and detector drift. The study demonstrated the potential of Raman spectroscopy in noninvasive applications and provides areas where the technology can be improved in future studies.

  20. Noninvasive glucose sensing by transcutaneous Raman spectroscopy.

    PubMed

    Shih, Wei-Chuan; Bechtel, Kate L; Rebec, Mihailo V

    2015-05-01

    We present the development of a transcutaneous Raman spectroscopy system and analysis algorithm for noninvasive glucose sensing. The instrument and algorithm were tested in a preclinical study in which a dog model was used. To achieve a robust glucose test system, the blood levels were clamped for periods of up to 45 min. Glucose clamping and rise/fall patterns have been achieved by injecting glucose and insulin into the ear veins of the dog. Venous blood samples were drawn every 5 min and a plasma glucose concentration was obtained and used to maintain the clamps, to build the calibration model, and to evaluate the performance of the system. We evaluated the utility of the simultaneously acquired Raman spectra to be used to determine the plasma glucose values during the 8-h experiment. We obtained prediction errors in the range of ~1.5-2  mM. These were in-line with a best-case theoretical estimate considering the limitations of the signal-to-noise ratio estimates. As expected, the transition regions of the clamp study produced larger predictive errors than the stable regions. This is related to the divergence of the interstitial fluid (ISF) and plasma glucose values during those periods. Two key contributors to error beside the ISF/plasma difference were photobleaching and detector drift. The study demonstrated the potential of Raman spectroscopy in noninvasive applications and provides areas where the technology can be improved in future studies.

  1. Plasma Catecholamines and Stress Assessment in Men Exposed to Moderate Altitudes.

    DTIC Science & Technology

    1982-01-01

    posure, as evidenced by a significant fall in PC02 and a respiratory alkalosis , was able to improve blood oxygenation. Heart rate did not fall with...Survey . . . . 21 Oxygen Content and P02 ...... .. ..... 33 Venous PCO2 :’" 33 Venous pH . .. . . . . . . .. 37 Respiratory Rate ............. ... 37 Blood...a 68 L. Venous PC02 Levels . ... .............. 69 M. Venous pH. . .9. . . . . . .. . . . . . . . . . . . 70 N. Respiratory Rates

  2. [Improving venous tone and capillary sealing. Effect of a combination of Ruscus extract and hesperidine methyl chalcone in healthy probands in heat stress].

    PubMed

    Rudofsky, G

    1989-06-30

    The drug combination of Ruscus-extract and hesperidine methyl chalcone (HMC) involves two basic mechanisms in the treatment of venous diseases: increase in venous tonicity and edema protection. This was shown in a double-blind study on 20 healthy volunteers by comparing the effectiveness of the individual substances, the combination and a placebo on the venous hemodynamics and the volume of the foot. Ruscus-extract augments the tonicity of the venous wall. This is expressed by a decrease in venous capacity (p less than 0.01), a reduction in the blood pool in the lower leg under orthostatic conditions, and a decrease in tissue volume of the foot and ankle (p less than 0.01). HMC lowers the capillary filtration rate (p less than 0.01) but augmented the blood pool. The increase in blood volume can be explained by dehydration of the tissue of the lower leg lowering the pressure of tissue on the venous system and increasing the blood pool in the limb. After administration of the combination, the blood volume was between the Ruscus and HMC volumes, while the effects on filtration rate, venous capacity and tissue volume corresponded to the changes seen after administration of HMC and Ruscus extract alone.

  3. Asymptomatic hepatic portal venous gas with gastric emphysema as a chronic complication of gastrostomy tube placement: a case report.

    PubMed

    Sawano, Toyoaki; Nemoto, Tsuyoshi; Tsubokura, Masaharu; Leppold, Claire; Ozaki, Akihiko; Kato, Shigeaki; Kanazawa, Yukio

    2016-08-24

    Percutaneous endoscopic gastrostomy feeding is widely used as a route for enteral feeding for patients with impaired swallowing ability, particularly in older patients. Hepatic portal venous gas is a condition that may arise from several causes. Hepatic portal venous gas that develops after an endoscopic procedure is generally reported to be nonfatal, yet there is little information available concerning the characteristics of hepatic portal venous gas as a chronic complication of percutaneous endoscopic gastrostomy feeding. We experienced a case of hepatic portal venous gas that happened to be detected in an 81-year-old Japanese man with long-term percutaneous endoscopic gastrostomy use who was admitted to our hospital with aspiration pneumonia. While aspiration pneumonia was treated with antibiotics and suspension of tube feedings, he recovered from hepatic portal venous gas without any treatment. The presence of a percutaneous endoscopic gastrostomy tube may have induced hepatic portal venous gas through a mechanism in which vomiting led to increased abdominal pressure and eventually gastric emphysema. This case suggests that hepatic portal venous gas without any signs of bowel ischemia or emphysematous gastritis can resolve without treatment, which is a finding that could be helpful for clinicians who deal with those supported by percutaneous endoscopic gastrostomy feeding.

  4. Deep cerebral venous thrombosis mimicking influenza-associated acute necrotizing encephalopathy: a case report.

    PubMed

    Taniguchi, Daisuke; Nakajima, Sho; Hayashida, Arisa; Kuroki, Takuma; Eguchi, Hiroto; Machida, Yutaka; Hattori, Nobutaka; Miwa, Hideto

    2017-09-26

    Acute necrotizing encephalopathy is one of the most devastating neurological complications of influenza virus infection. Acute necrotizing encephalopathy preferentially affects the thalamus bilaterally, as does deep cerebral venous thrombosis, which can lead to misdiagnosis. A 52-year-old Japanese woman infected with seasonal influenza B virus presented to the emergency care unit in our hospital with progressive alteration of her level of consciousness. Bilateral thalamic lesions were demonstrated by magnetic resonance imaging, leading to a tentative diagnosis of acute necrotizing encephalopathy. However, she had deep cerebral venous thrombosis, and the presence of diminished signal and enlargement of deep cerebral veins on T2*-weighted imaging contributed to a revised diagnosis of deep cerebral venous thrombosis. Anticoagulant therapy was initiated, leading to her gradual recovery, with recanalization of the deep venous system and straight sinus. To the best of our knowledge, these results represent the first report of deep cerebral venous thrombosis associated with influenza infection. It is clinically important to recognize that deep cerebral venous thrombosis, although rare, might be one of the neurological complications of influenza infection. In the presence of bilateral thalamic lesions in patients with influenza infection, deep cerebral venous thrombosis should be considered in addition to acute necrotizing encephalopathy. Delays in diagnosis and commencement of anticoagulant therapy can lead to unfavorable outcomes.

  5. Squamous cell carcinoma lung: Presented with bilateral lower limb deep venous thrombosis with gangrene formation

    PubMed Central

    Saha, Kaushik; Sengupta, Amitabha; Patra, Anupam; Jash, Debraj

    2013-01-01

    Bilateral venous thrombosis due to underlying malignancy is a rare entity. It is worthy to search for malignancy in patients of bilateral venous gangrene. Our patient presented with severe bilateral leg pain as a result of venous gangrene. There was associated left sided massive pleural effusion with scalp nodule. Fine needle aspiration cytology of scalp nodule revealed metastatic squamous cell carcinoma and fiber optic bronchoscopy guided biopsy from growth at left upper lobe bronchus confirmed the case as squamous cell carcinoma lung. It was rare for squamous cell carcinoma lung to present as bilateral venous gangrene with anticardiolipin antibody negative. PMID:24455526

  6. Differences in Temperature Changes in Premature Infants During Invasive Procedures in Incubators and Radiant Warmers.

    PubMed

    Handhayanti, Ludwy; Rustina, Yeni; Budiati, Tri

    Premature infants tend to lose heat quickly. This loss can be aggravated when they have received an invasive procedure involving a venous puncture. This research uses crossover design by conducting 2 intervention tests to compare 2 different treatments on the same sample. This research involved 2 groups with 18 premature infants in each. The process of data analysis used a statistical independent t test. Interventions conducted in an open incubator showed a p value of .001 which statistically related to heat loss in premature infants. In contrast, the radiant warmer p value of .001 statistically referred to a different range of heat gain before and after the venous puncture was given. The radiant warmer saved the premature infant from hypothermia during the invasive procedure. However, it is inadvisable for routine care of newborn infants since it can increase insensible water loss.

  7. Canine bombesin-like gastrin releasing peptides stimulate gastrin release and acid secretion in the dog.

    PubMed Central

    Bunnett, N W; Clark, B; Debas, H T; Del Milton, R C; Kovacs, T O; Orloff, M S; Pappas, T N; Reeve, J R; Rivier, J E; Walsh, J H

    1985-01-01

    The synthetic mammalian bombesin-like peptides, canine gastrin releasing peptide 27, 23 and 10, and porcine gastrin releasing peptide 27 were compared with amphibian bombesin 14 and 10 during intravenous infusions into six conscious dogs with chronic gastric cannulae. Gastrin and gastrin releasing peptide were measured in peripherally sampled venous blood by radioimmunoassay and gastric acid secretions were collected. All forms of gastrin releasing peptide stimulated gastrin release and gastric acid secretion in a dose-dependent manner. The larger canine and porcine peptides were more potent than the decapeptide. Bombesin 14 was more potent than bombesin 10. A rise in the venous concentration of immunoreactive gastrin releasing peptide of only 20 fmol ml-1 stimulated gastrin release to about 50% of maximal. Gastrin releasing peptide 10 was cleared from the circulation three times faster than the larger forms and this may account for the apparent differences in potency. PMID:3839849

  8. Detection of haemoglobins with abnormal oxygen affinity by single blood gas analysis and 2,3-diphosphoglycerate measurement.

    PubMed

    Guerrini, G; Morabito, A; Samaja, M

    2000-10-01

    The aim is to determine if a single measurement of blood 2,3-diphosphoglycerate combined with gas analysis (pH, PCO2, PO2 and saturation) can identify the cause of an altered blood-oxygen affinity: the presence of an abnormal haemoglobin or a red cell disorder. The population (n=94) was divided into healthy controls (A, n=14), carriers of red cell disorders (B, n=72) and carriers of high oxygen affinity haemoglobins (C, n=8). Those variables were measured both in samples equilibrated at selected PCO2 and PO2 and in venous blood. In the univariable approach applied to equilibrated samples, we correctly identified C subjects in 93.6% or 96.8% of the cases depending on the selected variable, the standard P50 (PO2 at which 50% of haemoglobin is oxygenated) or a composite variable calculated from the above measurements. After introducing the haemoglobin concentration as a further discriminating variable, the A and B subjects were correctly identified in 91.9% or 94.2% of the cases, respectively. These figures become 93.0% or 86.1%, and 93.7% or 94.9% of the cases when using direct readings from venous blood, thereby avoiding the blood equilibration step. This test is feasible also in blood samples stored at 4 degrees C for 48 h, or at room temperature for 8 h.

  9. Intensive educational efforts combined with external quality assessment improve the preanalytical phase in general practitioner offices and nursing homes.

    PubMed

    Sølvik, Una Ørvim; Bjelkarøy, Wenche Iren; Berg, Kari van den; Saga, Anne Lise; Hager, Helle Borgstrøm; Sandberg, Sverre

    2017-10-26

    Errors in the preanalytical phase in clinical laboratories affect patient safety. The aim of this study was to evaluate the effect of intensive educational efforts together with external quality assessment (EQA) of the preanalytical phase from 2013 to 2015 to improve patient identification in primary health care in Norway. In addition, routines for venous and capillary blood sampling were investigated. A preanalytical EQA was circulated in 2013 by the Norwegian Quality Improvement of Laboratory Examinations (Noklus) to general practitioner offices and nursing homes (n=2000) to obtain information about important issues to focus on before launching an intensive educational program with courses, posters and visits in 2013-2015. Preanalytical EQA surveys were further circulated in 2014 and 2015. The response rate varied between 42% and 55%. The percentages of participants asking for the patients' name and the Norwegian identification number increased from about 8% in 2013 to about 35% in 2015. The increase was similar for those participating in only one EQA survey and for those who participated in EQA surveys both in 2013 and 2015. Guidelines for venous and capillary blood sampling were not always followed. Educational efforts more than the preanalytical EQA influenced the actions and resulted in an increase in the percentages of participants that followed the guidelines for patient identification. Some aspects of blood sampling routines need improvement.

  10. Experimental investigation of the effects of inserting a bovine venous valve in the inferior vena cava of Fontan circulation

    NASA Astrophysics Data System (ADS)

    Santhanakrishnan, Arvind; Johnson, Jacob; Kotz, Monica; Tang, Elaine; Khiabani, Reza; Yoganathan, Ajit; Maher, Kevin

    2012-11-01

    The Fontan procedure is a palliative surgery performed on patients with single ventricle (SV) congenital heart defects. The SV is used for systemic circulation and the venous return from the inferior vena cava (IVC) and superior vena cava (SVC) is routed to the pulmonary arteries (PA), resulting in a total cavopulmonary connection (TCPC). Hepatic venous hypertension is commonly manifested in the Fontan circulation, leading to long-term complications including liver congestion and cirrhosis. Respiratory intrathoracic pressure changes affect the venous return from the IVC to the PA. Using a physical model of an idealized TCPC, we examine placement of a unidirectional bovine venous valve within the IVC as a method of alleviating hepatic venous hypertension. A piston pump is used to provide pulsatility in the internal flow through the TCPC, while intrathoracic pressure fluctuations are imposed on the external walls of the model using a pair of linear actuators. When implanted in the extrathoracic position, the hepatic venous pressure is lowered from baseline condition. The effects of changing caval flow distribution and intrathoracic pressure on TCPC hemodynamics will be examined.

  11. Patterns of chronic venous insufficiency in the dural sinuses and extracranial draining veins and their relationship with white matter hyperintensities for patients with Parkinson's disease.

    PubMed

    Liu, Manju; Xu, Haibo; Wang, Yuhui; Zhong, Yi; Xia, Shuang; Utriainen, David; Wang, Tao; Haacke, E Mark

    2015-06-01

    Idiopathic Parkinson's disease (IPD) remains one of those neurodegenerative diseases for which the cause remains unknown. Many clinically diagnosed cases of IPD are associated with cerebrovascular disease and white matter hyperintensities (WMHs). The purpose of this study was to investigate the presence of transverse sinus and extracranial venous abnormalities in IPD patients and their relationship with brain WMHs. Twenty-three IPD patients and 23 age-matched normal controls were recruited in this study. They had conventional neurologic magnetic resonance structural and angiographic scans and, for blood flow, quantification of the extracranial vessels. Venous structures were evaluated with two-dimensional time of flight; flow was evaluated with two-dimensional phase contrast; and WMH volume was quantified with T2-weighted fluid-attenuated inversion recovery. The IPD and normal subjects were classified by both the magnetic resonance time-of-flight and phase contrast images into four categories: (1) complete or local missing transverse sinus and internal jugular veins on the time-of-flight images; (2) low flow in the transverse sinus and stenotic internal jugular veins; (3) reduced flow in the internal jugular veins; and (4) normal flow and no stenosis. Broken into the four categories with categories 1 to 3 combined, a significant difference in the distribution of the IPD patients and normal controls (χ(2) = 7.7; P < .01) was observed. Venous abnormalities (categories 1, 2, and 3) were seen in 57% of IPD subjects and in only 30% of controls. In IPD subjects, category type correlated with both flow abnormalities and WMHs. From this preliminary study, we conclude that a major fraction of IPD patients appear to have abnormal venous anatomy and flow on the left side of the brain and neck and that the flow abnormalities appear to correlate with WMH volume. Studies with a larger sample size are still needed to confirm these findings. Copyright © 2015 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  12. Trial Protocol: A randomised controlled trial of extended anticoagulation treatment versus routine anticoagulation treatment for the prevention of recurrent VTE and post thrombotic syndrome in patients being treated for a first episode of unprovoked VTE (The ExACT Study)

    PubMed Central

    2013-01-01

    Background Venous thromboembolism comprising pulmonary embolism and deep vein thrombosis is a common condition with an incidence of approximately 1 per 1,000 per annum causing both mortality and serious morbidity. The principal aim of treatment of a venous thromboembolism with heparin and warfarin is to prevent extension or recurrence of clot. However, the recurrence rate following a deep vein thrombosis remains approximately 10% per annum following treatment cessation irrespective of the duration of anticoagulation therapy. Patients with raised D-dimer levels after discontinuing oral anticoagulation treatment have also been shown to be at high risk of recurrence. Post thrombotic syndrome is a complication of a deep vein thrombosis which can lead to chronic venous insufficiency and ulceration. It has a cumulative incidence after 2 years of around 25% and it has been suggested that extended oral anticoagulation should be investigated as a possible preventative measure. Methods/design Patients with a first idiopathic venous thromboembolism will be recruited through anticoagulation clinics and randomly allocated to either continuing or discontinuing warfarin treatment for a further 2 years and followed up on a six monthly basis. At each visit D-dimer levels will be measured using a Roche Cobas h 232 POC device. In addition a venous sample will be taken for laboratory D-dimer analysis at the end of the study. Patients will be examined for signs and symptoms of PTS using the Villalta scale and complete VEINES and EQ5D quality of life questionnaires. Discussion The primary aim of the study is to investigate whether extending oral anticoagulation treatment (prior to discontinuing treatment) beyond 3–6 months for patients with a first unprovoked proximal deep vein thrombosis or pulmonary embolism prevents recurrence. The study will also determine the role of extending anticoagulation for patients with elevated D-dimer levels prior to discontinuing treatment and identify the potential of D-dimer point of care testing for identification of high risk patients within a primary care setting. Trial registration ISRCTN73819751 PMID:23497371

  13. Monitoring skin microvascular dysfunction of type 1 diabetic mice using in vivo skin optical clearing

    NASA Astrophysics Data System (ADS)

    Feng, Wei; Shi, Rui; Zhu, Dan

    2018-02-01

    To monitor skin microvascular dysfunction of alloxan-induced type 1 diabetic mice model. In this work, we used laser speckle contrast imaging and hyperspectral imaging through in vivo skin optical clearing method to simultaneously monitor the noradrenaline-induced response of microvascular blood flow and blood oxygen with the development of diabetes. The main results showed that venous and arterious blood flow steadily decreased without recovery after injecting noradrenaline (NE), furthermore the influence of NE-induced arterious blood oxygen response greatly decreased, especially for 2-weeks and 4-weeks diabetic mice. This study demonstrated that skin microvascular function was a potential research biomarker for early warning in the occurrence and development of diabetes. And it provides a feasible solution to realize visualization of cutaneous microvessels for monitoring microvascular reactivity.

  14. A case of hirsutism due to bilateral diffuse ovarian Leydig cell hyperplasia in a post-menopausal woman.

    PubMed

    Ali, F S.M.; Stanaway, S E.R.S.; Zakhour, H D.; Spearing, G; Bowen-Jones, D

    2003-11-01

    Hyperandrogenism in females usually results from ovarian or adrenal pathology. We present a case of virilizaton due to very rare bilateral ovarian diffuse interstitial proliferation of Leydig cells with no tumour or hilar cell hyperplasia identified. Interestingly, the case was further complicated by the finding of high levels of testosterone in one adrenal vein on selective venous sampling (SVS), resulting in an unnecessary unilateral adrenalectomy. Further sampling found high levels also in the ovarian veins, and the condition was finally cured by bilateral oophorectomy.

  15. Present Concepts in Internal Medicine, Nutritional Support Symposium. Volume 14, Number 1. Summer 1983,

    DTIC Science & Technology

    1983-01-01

    7- peripheral intravenous route. CARE OF THE CENTRAL VENOUS CATHETER Central venous catheter insertion requires the follow- ing skin preparation: 1...receiving parenteral nutrition who develop sepsis from central venous catheters may show persistent temperature spikes to 38.9 *C to 40.0 *C every 12-24...hours. Evaluating the central venous catheter as the etiology for febrile episodes is often difficult because many patients have other potential

  16. Hydrothorax after Central Venous Catheterization

    PubMed Central

    Rudge, C. J.; Bewick, M.; McColl, I.

    1973-01-01

    Three patients are described who developed hydrothorax as a complication of central venous catheterization. Respiratory distress associated with physical signs of fluid in the chest should arouse suspicion that the venous catheter has perforated the wall of the vein. The complications of central venous catheterization are reviewed and three cases of hydrothorax are presented. Comments on the prevention of these complications, their diagnosis and treatment if they occur, are made. ImagesFIG. 1FIG. 2 PMID:4717421

  17. Measurement of Venous Blood Flow in the Lower Limbs: Prevention of Deep Vein Thrombosis during Prolonged Sitting

    DTIC Science & Technology

    2004-06-01

    Abstract. The venous blood flow during stretching and deep breathing in the sitting posture was examined in the present study. First, an...increase in the venous return. Therefore, we suggest that stretching and deep breathing can be used sometimes as preventive measures for deep vein...thrombosis during prolonged sitting. Keywords. Venous blood flow, Near infrared spectroscopy, Deep vein thrombosis. 1. Introduction It has been

  18. Extrinsic cerebral venous sinus obstruction resulting in intracranial hypertension

    PubMed Central

    Goldsmith, P; Burn, D; Coulthard, A; Jenkins, A

    1999-01-01

    We report the case of a 70-year-old man reporting with headache and visual disturbances who was being treated for prostate cancer. Investigations showed him to have intracranial hypertension caused by venous sinus obstruction. Patients with metastatic disease and raised intracranial pressure in the absence of focal signs should be considered as possible cases of venous outflow obstruction.


Keywords: intracranial hypertension; venous sinus thrombosis; malignancy PMID:10616691

  19. Acute venous sinus thrombosis after chickenpox infection.

    PubMed

    Sardana, Vijay; Mittal, Lal Chand; Meena, S R; Sharma, Deepti; Khandelwal, Girish

    2014-08-01

    Chickenpox is one of the classic childhood diseases. Recently chicken pox has been reported in adults with more severe systemic and neurological complications. Cerebral venous thrombosis (CVT) is a life threatening disorder if not treated in time. We report a patient with post varicella CVT as a rare complication of primary Varicella zoster virus. Vasculitic arterial infarction is known while venous stroke has rarely been reported with Varicella-zoster virus infection. Here, we report an immunocompetent 30 yr old male who developed chickenpox after contact with his daughter two month back. He presented with acute neurological deficit, one week after onset of skin lesion. MR venography revealed non-visualisation of left transverse sinus and left sigmoid sinus suggestive of venous sinus thrombosis. Varicella infection is rarely associated with venous sinus thrombosis. Possibly hypercoagulable state produced by the infection or direct invasion of virus in venous endothelial wall with subsequent damage to endothelium leading to thrombosis could be the cause.

  20. Occult pulmonary embolism: a common occurrence in deep venous thrombosis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dorfman, G.S.; Cronan, J.J.; Tupper, T.B.

    1987-02-01

    Ventilation-perfusion scans were used in a prospective study to determine the prevalence of occult pulmonary embolus in proven deep venous thrombosis. Fifty-eight patients without symptoms of pulmonary embolism, but with venographically proven deep venous thrombosis, were subjected to chest radiographs, /sup 99m/Tc macroaggregated-albumin perfusion scans, and /sup 133/Xe ventilation scans. Of the 49 patients with deep venous thrombosis proximal to the calf veins, 17 (35%) had high-probability scans. Of all 58 patients, only 12 (21%) had normal scans. When the study population was compared with a group of 430 patients described in reports of pulmonary perfusion in asymptomatic persons, amore » significantly higher percentage of high-probability scans was found in the study population with deep venous thrombosis. Baseline ventilation-perfusion lung scanning is valuable for patients with proven above-knee deep venous thrombosis.« less

  1. Stasis Dermatitis: Pathophysiology, Evaluation, and Management.

    PubMed

    Sundaresan, Swaminathan; Migden, Michael R; Silapunt, Sirunya

    2017-06-01

    Stasis dermatitis commonly occurs in older age. It is caused by venous hypertension resulting from retrograde flow due to incompetent venous valves, valve destruction, or obstruction of the venous system. Further tissue changes arise from an inflammatory process mediated by metalloproteinases, which are up-regulated by ferric ion from extravasated red blood cells. Stasis dermatitis presents initially as poorly demarcated erythematous plaques of the lower legs bilaterally, classically involving the medial malleolus. It is one of the spectrum of cutaneous findings that may result from chronic venous insufficiency. Its mimics include cellulitis, contact dermatitis, and pigmented purpuric dermatoses. Duplex ultrasound is useful in demonstrating venous reflux when the clinical diagnosis of stasis dermatitis is inadequate. Conservative treatment involves the use of compression therapy directed at improving ambulatory venous pressure. Interventional therapy currently includes minimally invasive techniques such as endovenous thermal ablation and ultrasound-guided foam sclerotherapy, which have supplanted the use of open surgical techniques.

  2. Unilateral Loss of Spontaneous Venous Pulsations in an Astronaut

    NASA Technical Reports Server (NTRS)

    Mader, Thomas H.; Gibson, C. Robert; Lee, Andrew G.; Patel, Nimesh; Hart, Steven; Pettit, Donald R.

    2014-01-01

    Spontaneous venous pulsations seen on the optic nerve head (optic disc) are presumed to be caused by fluctuations in the pressure gradient between the intraocular and retrolaminar venous systems. The disappearance of previously documented spontaneous venous pulsations is a well-recognized clinical sign usually associated with a rise in intracranial pressure and a concomitant bilateral elevation of pressure in the subarachnoid space surrounding the optic nerves. In this correspondence we report the unilateral loss of spontaneous venous pulsations in an astronaut 5 months into a long duration space flight. We documented a normal lumbar puncture opening pressure 8 days post mission. The spontaneous venous pulsations were also documented to be absent 21 months following return to Earth.. We hypothesize that these changes may have resulted from a chronic unilateral rise in optic nerve sheath pressure caused by a microgravity-induced optic nerve sheath compartment syndrome.

  3. Blue rubber bleb nevus syndrome with simultaneous neurological and skeletal involvement.

    PubMed

    Tzoufi, Meropi S; Sixlimiri, Polyxeni; Nakou, Iliada; Argyropoulou, Maria I; Stefanidis, Constantinos J; Siamopoulou-Mavridou, Antigone

    2008-08-01

    Blue rubber bleb nevus syndrome (BRBNS) is a rare disorder characterized by venous malformations usually affecting the skin and the gastrointestinal tract. These skin haemangiomas are present at birth and deteriorate as the body grows, causing primarily cosmetic problems. The haemangiomas of the gastrointestinal tract may appear later in life and may bleed, causing chronic anaemia, or may present with severe complications such as rupture, intestinal torsion, and intussusception. Other organs may also be involved. This article describes a 13-year-old boy with multiple haemangiomas of the skin, the mucous membranes, and the gastrointestinal tract, which caused anaemia and ileoileic intussusception. In this patient, the nervous system was significantly affected with a haemangioma of the left occipital lobe, with complications of stroke. He also had multiple paravertebral heamangiomas, which caused pressure signs and symptoms. This boy suffered from complex partial and generalized seizures and cerebral palsy. Multiple skeletal anomalies were also present from birth. In the relevant literature, this is the first case of BRBNS with simultaneous neurological and skeletal involvement. Such cases should be recognized early, as they can lead to serious multiple health problems and handicaps.

  4. Observational study on immune response to yellow fever and measles vaccines in 9 to 15-month old children. Is it necessary to wait 4 weeks between two live attenuated vaccines?

    PubMed

    Michel, R; Berger, F; Ravelonarivo, J; Dussart, P; Dia, M; Nacher, M; Rogier, S; Moua, D; Sarr, F D; Diop, O M; Sall, A A; Baril, L

    2015-05-11

    The use of 2 live attenuated vaccines (LAV) is recommended to be simultaneous or after an interval of at least four weeks between injections. The primary objective of this study was to compare the humoral response to yellow fever (YF) and measles vaccines among children vaccinated against these two diseases, either simultaneously or separated by an interval of 7-28 days. A prospective, multicenter observational study was conducted among children aged 9-15 months. The primary endpoint was the occurrence of positive yellow fever antibodies after YF vaccine by estimating the titers of neutralizing antibodies from venous blood samples. Children vaccinated against YF 7-28 days after receiving the vaccine against measles (test group) were compared with children vaccinated the same day against these two diseases (referent group). Analysis was performed on 284 children. Of them, fifty-four belonged to the test group. Measles serology was positive in 91.7% of children. Neutralizing antibodies against YF were detected in 90.7% of the test group and 92.9 of the referent group (p=0.6). In addition, quantitative analysis of the immune response did not show a lower response to YF vaccination when it took place 1-28 days after measles vaccination. In 1965, Petralli showed a lower response to the smallpox vaccine when injected 4-20 days after measles vaccination. Since then, recommendations are to observe an interval of four weeks between LAV not injected on the same day. Other published studies failed to show a significant difference in the immune response to a LAV injected 1-28 days after another LAV. These results suggest that the usual recommendations for immunization with two LAV may not be correct. In low income countries, the current policy should be re-evaluated. This re-evaluation should also be applied to travelers to yellow fever endemic countries. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. Noninvasive optoacoustic system for rapid diagnosis and management of circulatory shock

    NASA Astrophysics Data System (ADS)

    Petrov, Irene Y.; Kinsky, Michael; Petrov, Yuriy; Petrov, Andrey; Henkel, S. N.; Seeton, Roger; Esenaliev, Rinat O.; Prough, Donald S.

    2013-03-01

    Circulatory shock can lead to death or severe complications, if not promptly diagnosed and effectively treated. Typically, diagnosis and management of circulatory shock are guided by blood pressure and heart rate. However, these variables have poor specificity, sensitivity, and predictive value. Early goal-directed therapy in septic shock patients, using central venous catheterization (CVC), reduced mortality from 46.5% to 30%. However, CVC is invasive and complication-prone. We proposed to use an optoacoustic technique for noninvasive, rapid assessment of peripheral and central venous oxygenation. In this work we used a medical grade optoacoustic system for noninvasive, ultrasound image-guided measurement of central and peripheral venous oxygenation. Venous oxygenation during shock declines more rapidly in the periphery than centrally. Ultrasound imaging of the axillary [peripheral] and internal jugular vein [central] was performed using the Vivid e (GE Healthcare). We built an optoacoustic interface incorporating an optoacoustic transducer and a standard ultrasound imaging probe. Central and peripheral venous oxygenations were measured continuously in healthy volunteers. To simulate shock-induced changes in central and peripheral oxygenation, we induced peripheral vasoconstriction in the upper extremity by using a cooling blanket. Central and peripheral venous oxygenations were measured before (baseline) and after cooling and after rewarming. During the entire experiment, central venous oxygenation was relatively stable, while peripheral venous oxygenation decreased by 5-10% due to cooling and recovered after rewarming. The obtained data indicate that noninvasive, optoacoustic measurements of central and peripheral venous oxygenation may be used for diagnosis and management of circulatory shock with high sensitivity and specificity.

  6. Venous thromboembolism associated with air travel: a report of 33 patients.

    PubMed

    Mercer, A; Brown, J D

    1998-02-01

    The medical literature suggests long distance travel, particularly air travel, may be a risk factor for venous thromboembolism, but the risk is poorly quantified. We reviewed 134 records of patients hospitalized with venous thromboembolism for comments regarding recent travel. Patients who had traveled within 31 d prior to venous thromboembolism were defined as recent travelers. Of 134 patients records, 66 (49%) had documented inquiries regarding travel and 33 (50%) were recent air travelers. Data regarding demographics, mode of travel, day of onset of symptoms in relation to travel, and other risk factors for venous thromboembolism were abstracted from the records of the recent travelers. There were 12 (36%) travelers who had no other predisposition for venous thromboembolism. All had traveled non-stop by aircraft for 4 or more hours; none was identified as a crew-member. The median day of onset of venous thromboembolism was on travel day 4 (range: day 1-31). There were 8 (24%) patients who had onset during air travel or on the day of arrival, and 27 (82%) had onset by travel day 15. Air travel for 4 or more hours within the preceding 31 d was the most common risk factor for venous thromboembolism in our study patients and was present in 50%. This incidence is much higher than previously described, perhaps due to limiting the study population to those in which the presence or absence of travel was documented. Prospective studies are needed to better define the risk factors for venous thromboembolism among long distance air passengers and crew-members, and to determine effective preventive measures.

  7. Computed tomographic characteristics of collateral venous pathways in dogs with caudal vena cava obstruction.

    PubMed

    Specchi, Swan; d'Anjou, Marc-André; Carmel, Eric Norman; Bertolini, Giovanna

    2014-01-01

    Collateral venous pathways develop in dogs with obstruction or increased blood flow resistance at any level of the caudal vena cava in order to maintain venous drainage to the right atrium. The purpose of this retrospective study was to describe the sites, causes of obstruction, and configurations of venous collateral pathways for a group of dogs with caudal vena cava obstruction. Computed tomography databases from two veterinary hospitals were searched for dogs with a diagnosis of caudal vena cava obstruction and multidetector row computed tomographic angiographic (CTA) scans that included the entire caudal vena cava. Images for each included dog were retrieved and collateral venous pathways were characterized using image postprocessing and a classification system previously reported for humans. A total of nine dogs met inclusion criteria and four major collateral venous pathways were identified: deep (n = 2), portal (n = 2), intermediate (n = 7), and superficial (n = 5). More than one collateral venous pathway was present in 5 dogs. An alternative pathway consisting of renal subcapsular collateral veins, arising mainly from the caudal pole of both kidneys, was found in three dogs. In conclusion, findings indicated that collateral venous pathway patterns similar to those described in humans are also present in dogs with caudal vena cava obstruction. These collateral pathways need to be distinguished from other vascular anomalies in dogs. Postprocessing of multidetector-row CTA images allowed delineation of the course of these complicated venous pathways and may be a helpful adjunct for treatment planning in future cases. © 2014 American College of Veterinary Radiology.

  8. Risk factors for venous thrombosis associated with peripherally inserted central venous catheters

    PubMed Central

    Pan, Longfang; Zhao, Qianru; Yang, Xiangmei

    2014-01-01

    To evaluate the risk factors associated with an increased risk of symptomatic peripherally inserted central venous catheter (PICC)-related venous thrombosis. Retrospective analyses identified 2313 patients who received PICCs from 1 January 2012 to 31 December 2013. All 11 patients with symptomatic PICC-related venous thrombosis (thrombosis group) and 148 who did not have thromboses (non-thrombosis group) were selected randomly. The medical information of 159 patients (age, body mass index (BMI), diagnosis, smoking history, nutritional risk score, platelet count, leucocyte count as well as levels of D-dimer, fibrinogen, and degradation products of fibrin) were collected. Logistic regression analysis was undertaken to determine the risk factors for thrombosis. Of 2313 patients, 11 (0.47%) were found to have symptomatic PICC-related venous thrombosis by color Doppler ultrasound. Being bedridden for a long time (odds ratio [(OR]), 17.774; P=0.0017), D-dimer >5 mg/L (36.651; 0.0025) and suffering from one comorbidity (8.39; 0.0265) or more comorbidities (13.705; 0.0083) were the major risk factors for PICC-catheter related venous thrombosis by stepwise logistic regression analysis. Among 159 patients, the prevalence of PICC-associated venous thrombosis in those with ≥1 risk factor was 10.34% (12/116), in those with ≥2 risk factors was 20.41% (10/49), and in those with >3 risk factors was 26.67% (4/15). Being bedridden >72 h, having increased levels of D-dimer (>5 mg/L) and suffering from comorbidities were independent risk factors of PICC-related venous thrombosis. PMID:25664112

  9. Gravitational effects on global hemodynamics in different postures: A closed-loop multiscale mathematical analysis

    NASA Astrophysics Data System (ADS)

    Zhang, Xiancheng; Noda, Shigeho; Himeno, Ryutaro; Liu, Hao

    2017-06-01

    We present a novel methodology and strategy to predict pressures and flow rates in the global cardiovascular network in different postures varying from supine to upright. A closed-loop, multiscale mathematical model of the entire cardiovascular system (CVS) is developed through an integration of one-dimensional (1D) modeling of the large systemic arteries and veins, and zero-dimensional (0D) lumped-parameter modeling of the heart, the cardiac-pulmonary circulation, the cardiac and venous valves, as well as the microcirculation. A versatile junction model is proposed and incorporated into the 1D model to cope with splitting and/or merging flows across a multibranched junction, which is validated to be capable of estimating both subcritical and supercritical flows while ensuring the mass conservation and total pressure continuity. To model gravitational effects on global hemodynamics during postural change, a robust venous valve model is further established for the 1D venous flows and distributed throughout the entire venous network with consideration of its anatomically realistic numbers and locations. The present integrated model is proven to enable reasonable prediction of pressure and flow rate waveforms associated with cardiopulmonary circulation, systemic circulation in arteries and veins, as well as microcirculation within normal physiological ranges, particularly in mean venous pressures, which well match the in vivo measurements. Applications of the cardiovascular model at different postures demonstrate that gravity exerts remarkable influence on arterial and venous pressures, venous returns and cardiac outputs whereas venous pressures below the heart level show a specific correlation between central venous and hydrostatic pressures in right atrium and veins.

  10. Endovascular intervention for central venous cannulation in patients with vascular occlusion after previous catheterization.

    PubMed

    Pikwer, Andreas; Acosta, Stefan; Kölbel, Tilo; Åkeson, Jonas

    2010-01-01

    This study was designed to assess endovascular intervention for central venous cannulation in patients with vascular occlusion after previous catheterization. Patients referred for endovascular management of central venous occlusion during a 42-month period were identified from a regional endovascular database, providing prospective information on techniques and clinical outcome. Corresponding patient records, angiograms, and radiographic reports were analyzed retrospectively. Sixteen patients aged 48 years (range 0.5-76), including 11 females, were included. All patients but 1 had had multiple central venous catheters with a median total indwelling time of 37 months. Eleven patients cannulated for hemodialysis had had significantly fewer individual catheters inserted compared with 5 patients cannulated for nutritional support (mean 3.6 vs. 10.2, p<0.001) before endovascular intervention. Preoperative imaging by magnetic resonance tomography (MRT) in 8 patients, computed tomography (CT) venography in 3, conventional angiography in 6, and/or ultrasonography in 8, verified 15 brachiocephalic, 13 internal jugular, 3 superior caval, and/or 3 subclavian venous occlusions. Patients were subjected to recanalization (n=2), recanalization and percutaneous transluminal angioplasty (n=5), or stenting for vena cava superior syndrome (n=1) prior to catheter insertion. The remaining 8 patients were cannulated by avoiding the occluded route. Central venous occlusion occurs particularly in patients under hemodialysis and with a history of multiple central venous catheterizations with large-diameter catheters and/or long total indwelling time periods. Patients with central venous occlusion verified by CT or MRT venography and need for central venous access should be referred for endovascular intervention.

  11. Effects of abdominal pressure on venous return: abdominal vascular zone conditions.

    PubMed

    Takata, M; Wise, R A; Robotham, J L

    1990-12-01

    The effects of changes in abdominal pressure (Pab) on inferior vena cava (IVC) venous return were analyzed using a model of the IVC circulation based on a concept of abdominal vascular zone conditions analogous to pulmonary vascular zone conditions. We hypothesized that an increase in Pab would increase IVC venous return when the IVC pressure at the level of the diaphragm (Pivc) exceeds the sum of Pab and the critical closing transmural pressure (Pc), i.e., zone 3 conditions, but reduce IVC venous return when Pivc is below the sum of Pab and Pc, i.e., zone 2 conditions. The validity of the model was tested in 12 canine experiments with an open-chest IVC bypass. An increase in Pab produced by phrenic stimulation increased the IVC venous return when Pivc-Pab was positive but decreased the IVC venous return when Pivc - Pab was negative. The value of Pivc - Pab that separated net increases from decreases in venous return was 1.00 +/- 0.72 (SE) mmHg (n = 6). An increase in Pivc did not influence the femoral venous pressure when Pivc was lower than the sum of Pab and a constant, 0.96 +/- 0.70 mmHg (n = 6), consistent with presence of a waterfall. These results agreed closely with the predictions of the model and its computer simulation. The abdominal venous compartment appears to function with changes in Pab either as a capacitor in zone 3 conditions or as a collapsible Starling resistor with little wall tone in zone 2 conditions.

  12. [Controlled study of increasing venous tone in primary varicose veins by oral administration of Ruscus aculeatus and trimethylhespiridinchalcone].

    PubMed

    Weindorf, N; Schultz-Ehrenburg, U

    1987-01-01

    In a randomized double blind study, 50 patients suffering from trunk or branch varicosis were orally treated with either a commercial preparation of Ruscus extract, trimethyl hesperidine chalcone and ascorbic acid (Phlebodril), or a placebo over 2 weeks. Changes of the venous tonus were measured by means of venous occlusion plethysmography in rest position (venous capacity, venous distensibility) as well as during (active) exercise (expelled blood volume). All parameters showed a tendency towards improvement in the verum group. The changes were partly significant (p less than 0.5). The course of the study suggests that the period of treatment possibly was too short to obtain the full pharmacologic effect.

  13. Liquid transmission characteristics of padding bandages under pressure.

    PubMed

    Kumar, Bipin; Das, Apurba; Pan, Ning; Alagirusamy, R; Gupta, Rupali; Singh, Jitender

    2015-11-01

    Padding is an essential component in a multilayer compression bandaging system, used inside the compression bandage through which substantial amount of pressure is exerted on the limb of patient for treatment of venous leg ulcers. As a result, the liquid transmission behavior of padding is also critical in managing body fluids or sweat exuded from the affected limb, reducing the excessive moisture build-up around the wound and thereby ensuring comfort to and hence a better compliance from the patients. This study investigates the in-plane fluid transport characteristics of needle-punched nonwoven padding bandages. It first reviewed the existing studies related to the problems, and discussed their limits and possible improvements in dealing with complex fluid transport issues in textile porous media. The measurement of fluid transport under different pressure levels was then done using a newly designed apparatus capable of simultaneously tracing the liquid in-plane spreading along different directions, and obtaining several transport characteristics of a testing sample, e.g. the liquid flow anisotropy, the rate of movement, the area of wet surface with time, etc. Also the effects of several important factors, such as the levels of pressure applied, the specimen bulk density, and needling density of the padding products, have been experimentally investigated. In addition, based on an extended Lucas-Washburn theory, we calculated the liquid flow distance, both instantaneous speed and a more useful time-averaged speed v(av) at any given direction, and also defined a flow anisotropy index I(A) as a convenient parameter to represent the material flow anisotropy. The applications of v(av) and I(A) to actual samples have demonstrated the usefulness of these parameters in characterizing the flow nature and behavior of the materials. © The Author(s) 2015.

  14. The Toxicity of Inhaled Sulphur Mustard

    DTIC Science & Technology

    2012-10-01

    Index − CO – Cardiac Output − CvO2 – Mixed Venous Oxygenation − CVP – Central Venous Pressure − DO2 – Oxygen Delivery − dpMax – Maximum...in central venous pressure following exposure to HD: HD controls () and HD + NAC (). Data are expressed as mean ± SEM. UK UNCLASSIFIED Page 64 of...Respiratory rate (RR) Heart rate (HR) Expired CO2 Pulse oximetry Mean arterial pressure Central venous pressure Blood Chemistry (arterial and

  15. A new approach to non-invasive oxygenated mixed venous PCO(sub)2

    NASA Technical Reports Server (NTRS)

    Fisher, Joseph A.; Ansel, Clifford A.

    1986-01-01

    A clinically practical technique was developed to calculate mixed venous CO2 partial pressure for the calculation of cardiac output by the Fick technique. The Fick principle states that the cardiac output is equal to the CO2 production divided by the arterio-venous CO2 content difference of the pulmonary vessels. A review of the principles involved in the various techniques used to estimate venous CO2 partial pressure is presented.

  16. The Ovine Cerebral Venous System: Comparative Anatomy, Visualization, and Implications for Translational Research

    PubMed Central

    Nitzsche, Björn; Lobsien, Donald; Seeger, Johannes; Schneider, Holm; Boltze, Johannes

    2014-01-01

    Cerebrovascular diseases are significant causes of death and disability in humans. Improvements in diagnostic and therapeutic approaches strongly rely on adequate gyrencephalic, large animal models being demanded for translational research. Ovine stroke models may represent a promising approach but are currently limited by insufficient knowledge regarding the venous system of the cerebral angioarchitecture. The present study was intended to provide a comprehensive anatomical analysis of the intracranial venous system in sheep as a reliable basis for the interpretation of experimental results in such ovine models. We used corrosion casts as well as contrast-enhanced magnetic resonance venography to scrutinize blood drainage from the brain. This combined approach yielded detailed and, to some extent, novel findings. In particular, we provide evidence for chordae Willisii and lateral venous lacunae, and report on connections between the dorsal and ventral sinuses in this species. For the first time, we also describe venous confluences in the deep cerebral venous system and an ‘anterior condylar confluent’ as seen in humans. This report provides a detailed reference for the interpretation of venous diagnostic imaging findings in sheep, including an assessment of structure detectability by in vivo (imaging) versus ex vivo (corrosion cast) visualization methods. Moreover, it features a comprehensive interspecies-comparison of the venous cerebral angioarchitecture in man, rodents, canines and sheep as a relevant large animal model species, and describes possible implications for translational cerebrovascular research. PMID:24736654

  17. Cardiovascular Pressures with Venous Gas Embolism and Decompression

    NASA Technical Reports Server (NTRS)

    Butler, B. D.; Robinson, R.; Sutton, T.; Kemper, G. B.

    1995-01-01

    Venous gas embolism (VGE) is reported with decompression to a decreased ambient pressure. With severe decompression, or in cases where an intracardiac septal defect (patent foramen ovale) exists, the venous bubbles can become arterialized and cause neurological decompression illness. Incidence rates of patent foramen ovale in the general population range from 25-34% and yet aviators, astronauts, and deepsea divers who have decompression-induced venous bubbles do not demonstrate neurological symptoms at these high rates. This apparent disparity may be attributable to the normal pressure gradient across the atria of the heart that must be reversed for there to be flow potency. We evaluated the effects of: venous gas embolism (0.025, 0.05 and 0.15 ml/ kg min for 180 min.) hyperbaric decompression; and hypobaric decompression on the pressure gradient across the left and right atria in anesthetized dogs with intact atrial septa. Left ventricular end-diastolic pressure was used as a measure of left atrial pressure. In a total of 92 experimental evaluations in 22 dogs, there were no reported reversals in the mean pressure gradient across the atria; a total of 3 transient reversals occurred during the peak pressure gradient changes. The reasons that decompression-induced venous bubbles do not consistently cause serious symptoms of decompression illness may be that the amount of venous gas does not always cause sufficient pressure reversal across a patent foramen ovale to cause arterialization of the venous bubbles.

  18. Cerebral venous infarction: a potentially avoidable complication of deep brain stimulation surgery.

    PubMed

    Morishita, Takashi; Okun, Michael S; Burdick, Adam; Jacobson, Charles E; Foote, Kelly D

    2013-01-01

    Despite numerous reports on the morbidity and mortality of deep brain stimulation (DBS), cerebral venous infarction has rarely been reported. We present four cases of venous infarct secondary to DBS surgery. The diagnosis of venous infarction was based on 1) delayed onset of new neurologic deficits on postoperative day 1 or 2; 2) significant edema surrounding the superficial aspect of the implanted lead, with or without subcortical hemorrhage on CT scan. Four cases (0.8% per lead, 1.3% per patient) of symptomatic cerebral venous infarction were identified out of 500 DBS lead implantation procedures between July 2002 and August 2009. All four patients had Parkinson's disease. Their DBS leads were implanted in the subthalamic nucleus (n = 2), and the globus pallidus internus (n = 2). Retrospective review of the targeting confirmed that the planned trajectory passed within 3 mm of a cortical vein in two cases for which contrast-enhanced preoperative magnetic resonance (MR) imaging was available. In the other two cases, contrasted targeting images were not obtained preoperatively. Cerebral venous infarction is a potentially avoidable, but serious complication. To minimize its incidence, we propose the use of high-resolution, contrast-enhanced, T1-weighted MR images to delineate cerebral venous anatomy, along with careful stereotactic planning of the lead trajectory to avoid injury to venous structures. © 2013 International Neuromodulation Society.

  19. Extended Venous Thromboembolism Prophylaxis after Radical Cystectomy: A Call for Adherence to Current Guidelines.

    PubMed

    Klaassen, Zachary; Arora, Karan; Goldberg, Hanan; Chandrasekar, Thenappan; Wallis, Christopher J D; Sayyid, Rashid K; Fleshner, Neil E; Finelli, Antonio; Kutikov, Alexander; Violette, Philippe D; Kulkarni, Girish S

    2018-04-01

    Radical cystectomy is inherently associated with morbidity. We assess the timing and incidence of venous thromboembolism, review current guideline recommendations and provide evidence for considering extended venous thromboembolism prophylaxis in all patients undergoing radical cystectomy. We searched PubMed® for available literature on radical cystectomy and venous thromboembolism, focusing on incidence and timing, evidence supporting extended venous thromboembolism prophylaxis in patients undergoing radical cystectomy or abdominal oncologic surgery, current guideline recommendations, safety considerations and direct oral anticoagulants. Search terms included "radical cystectomy," "venous thromboembolism," "prophylaxis," and "extended oral anticoagulants" and "direct oral anticoagulants" alone and in combination. Relevant articles were reviewed, including original research, reviews and clinical guidelines. References from review articles and guidelines were also assessed to develop a narrative review. The incidence of symptomatic venous thromboembolism in short-term followup after radical cystectomy is 3% to 11.6%, of which more than 50% of cases will occur after hospital discharge. Meta-analyses of clinical trials in patients undergoing major abdominal oncologic operations suggest a decreased risk of venous thromboembolisms for patients receiving extended (4 weeks) venous thromboembolism prophylaxis. Extended prophylaxis should be considered in all radical cystectomy cases. Although the relative risk of bleeding also increases, the overall net benefit of extended prophylaxis clearly favors use for at least 28 days postoperatively. Extrarenal eliminated prophylaxis agents are preferred given the risk of renal insufficiency in radical cystectomy cases, with newer oral anticoagulants providing an alternative route of administration. Patients undergoing radical cystectomy are at high risk for venous thromboembolism after hospital discharge. There is strong evidence that extended prophylaxis significantly decreases the risk of venous thromboembolism in oncologic surgery cases. Use of extended prophylaxis after radical cystectomy has been poorly adopted, emphasizing the need for better adherence to current urology procedure specific guidelines as extended prophylaxis for radical cystectomy is the standard of care. Specific and rare circumstances may require case by case assessment. Copyright © 2018 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  20. Perimesencephalic nonaneurysmal subarachnoid hemorrhage caused by transverse sinus thrombosis: A case report and review of literature.

    PubMed

    Fu, Fang-Wang; Rao, Jie; Zheng, Yuan-Yuan; Song, Liang; Chen, Wei; Zhou, Qi-Hui; Yang, Jian-Guang; Ke, Jiang-Qiong; Zheng, Guo-Qing

    2017-08-01

    Perimesencephalic nonaneurysmal subarachnoid hemorrhage (PNSAH) is characterized by a pattern of extravasated blood restricted to the perimesencephalic cisterns, normal angiographic findings, and an excellent prognosis with an uneventful course and low risks of complication. The precise etiology of bleeding in patients with PNSAH has not yet been established. The most common hypothesis is that PNSAH is venous in origin. Intracranial venous hypertension has been considered as the pivotal factor in the pathogenesis of PNSAH. The underlying venous pathology such as straight sinus stenosis, jugular vein occlusion may contribute to PNSAH. We describe a patient in whom transverse sinus thrombosis preceded intracranial venous hypertension and PNSAH. These findings supported that the source of the subarachnoid hemorrhage is venous in origin. A 45-year-old right-handed man was admitted to the hospital with a sudden onset of severe headache associated with nausea, vomiting, and mild photophobia for 6 hours. The patient was fully conscious and totally alert. An emergency brain computed tomography (CT) revealed an acute subarachnoid hemorrhage restricted to the perimesencephalic cisterns. CT angiography revealed no evidence of an intracranial aneurysm or underlying vascular malformation. Digital subtraction angiography of arterial and capillary phases confirmed the CT angiographic findings. Assessment of the venous phase demonstrated right transverse sinus thrombosis. Magnetic resonance imaging confirmed the diagnosis of cerebral venous sinus thrombosis (CVST). Lumbar puncture revealed an opening pressure of 360 mmH2O, suggestive of intracranial venous hypertension. Grave disease was diagnosed by endocrinological investigation. Low-molecular-weight heparin, followed by oral warfarin, was initiated immediately as the treatment for cerebral venous sinus thrombosis and PNSAH. The patient discharged without any neurologic defect after 3 weeks of hospital stay. MR venography revealed recanalization of right transverse sinus at the 6-month follow-up. No clinical or neuroimaging evidence of relapse was detected at 12 months follow-up. Hyperthyroidism may contribute to the development of CVST. The presence of acute transverse sinus thrombosis, as a cause of PNSAH, provides further support for the hypothesis that the source of PNSAH is venous in origin and intracranial venous hypertension plays a critical role in the pathogenesis of PNSAH.

Top