Dynamics of Single-Photon Emission from Electrically Pumped Color Centers
NASA Astrophysics Data System (ADS)
Khramtsov, Igor A.; Agio, Mario; Fedyanin, Dmitry Yu.
2017-08-01
Low-power, high-speed, and bright electrically driven true single-photon sources, which are able to operate at room temperature, are vital for the practical realization of quantum-communication networks and optical quantum computations. Color centers in semiconductors are currently the best candidates; however, in spite of their intensive study in the past decade, the behavior of color centers in electrically controlled systems is poorly understood. Here we present a physical model and establish a theoretical approach to address single-photon emission dynamics of electrically pumped color centers, which interprets experimental results. We support our analysis with self-consistent numerical simulations of a single-photon emitting diode based on a single nitrogen-vacancy center in diamond and predict the second-order autocorrelation function and other emission characteristics. Our theoretical findings demonstrate remarkable agreement with the experimental results and pave the way to the understanding of single-electron and single-photon processes in semiconductors.
Public School Center vs. Family Home Day Care: Single Parents' Reasons for Selection.
ERIC Educational Resources Information Center
Rothschild, Maria Stupp
This study investigates the reasons single parents in San Diego had for choosing either a public day care center or a licensed day care home for their children. A sample of 30 single parents with children in school district administered children's centers was drawn and matched by a similarly geographically distributed sample of 23 parents with…
Mantke, Rene; Diener, Markus; Kropf, Siegfried; Otto, Ronny; Manger, Thomas; Vestweber, Boris; Mirow, Lutz; Winde, Günther; Lippert, Hans
2016-09-07
Increasing experience with minimally invasive surgery and the development of new instruments has resulted in a tendency toward reducing the number of abdominal skin incisions. Retrospective and randomized prospective studies could show the feasibility of single-incision surgery without any increased risk to the patient. However, large prospective multicenter observational datasets do not currently exist. This prospective multicenter observational quality study will provide a relevant dataset reflecting the feasibility and safety of single-incision surgery. This study focuses on external validity, clinical relevance, and the patients' perspective. Accordingly, the single-incision multiport/single port laparoscopic abdominal surgery (SILAP) study will supplement the existing evidence, which does not currently allow evidence-based surgical decision making. The SILAP study is an international prospective multicenter observational quality study. Mortality, morbidity, complications during surgery, complications postoperatively, patient characteristics, and technical aspects will be monitored. We expect more than 100 surgical centers to participate with 5000 patients with abdominal single-incision surgery during the study period. Funding was obtained in 2012. Enrollment began on January 01, 2013, and will be completed on December 31, 2018. As of January 2016, 2119 patients have been included, 106 German centers are registered, and 27 centers are very active (>5 patients per year). This prospective multicenter observational quality study will provide a relevant dataset reflecting the feasibility and safety of single-incision surgery. An international enlargement and recruitment of centers outside of Germany is meaningful. German Clinical Trials Register: DRKS00004594; https://drks-neu.uniklinik-freiburg.de/drks_web/navigate.do?navigationId=trial.HTML&TRIAL_ID=DRKS00004594 (Archived by WebCite at http://www.webcitation.org/6jK6ZVyUs).
Quantum logic readout and cooling of a single dark electron spin
NASA Astrophysics Data System (ADS)
Shi, Fazhan; Zhang, Qi; Naydenov, Boris; Jelezko, Fedor; Du, Jiangfeng; Reinhard, Friedemann; Wrachtrup, Jörg
2013-05-01
We study a single dark N2 electron spin defect in diamond, which is magnetically coupled to a nearby nitrogen-vacancy (NV) center. We perform pulsed electron spin resonance on this single spin by mapping its state to the NV center spin and optically reading out the latter. Moreover, we show that the NV center's spin polarization can be transferred to the electron spin by combined two decoupling control-NOT gates. These two results allow us to extend the NV center's two key properties—optical spin polarization and detection—to any electron spin in its vicinity. This enables dark electron spins to be used as local quantum registers and engineerable memories.
The advantages and disadvantages of centralized control of air power at operational level
NASA Astrophysics Data System (ADS)
Arisoy, Uǧur
2014-05-01
People do not want to see and hear a war. In today's world, if war is inevitable, the use of air power is seen as the preferable means of conducting operations instead of financially burdensome land battles which are more likely to cause heavy loss of life. The use of Air Power has gained importance in NATO operations in the Post-Cold War era. For example, air power has undertaken a decisive role from the beginning to the end of the operation in Libya. From this point of view, the most important issue to consider is how to direct air power more effectively at operational level. NATO's Core JFAC (Joint Force Air Command) was established in 2012 to control joint air power at operational level from a single center. US had experienced JFAC aproach in the Operation Desert Storm in 1991. UK, France, Germany, Italy and Spain are also directing their air power from their JFAC structures. Joint air power can be directed from a single center at operational level by means of JFAC. JFAC aproach provides complex planning progress of Air Power to be controled faster in a single center. An Air Power with a large number of aircrafts, long range missiles of cutting-edge technology may have difficulties in achieving results unless directed effectively. In this article, directing air power more effectively at operational level has been studied in the framework of directing air power from a single center carried out by SWOT analysis technique. "Directing Air Power at operational level from a single center similar to JFAC-like structure" is compared with "Directing Air Power at operational level from two centers similar to AC (Air Command) + CAOC (Combined Air Operations Center) structure" As a result of this study, it is assessed that directing air power at operational level from a single center would bring effectiveness to the air campaign. The study examines directing air power at operational level. Developments at political, strategic and tactical levels have been ignored.
EPR study of the effect of ionizing radiation on chromium centers in Mg2SiO4: Cr,Li laser crystals
NASA Astrophysics Data System (ADS)
Akhmetzyanov, D. A.; Dudnikova, V. B.; Zharikov, E. V.; Zhiteitsev, E. R.; Konovalov, A. A.; Tarasov, V. F.
2013-09-01
Forsterite single crystals doped with chromium and lithium and exposed to ionizing radiation have been studied using multifrequency electron paramagnetic resonance (EPR) spectroscopy. It has been found that ionizing irradiation up to a dose of 108 rad does not lead to a significant change in the concentration of single chromium impurity centers. At the same time, γ-ray irradiation of the crystal leads to a decrease in the concentration of active laser centers, which form an associate of trivalent chromium and monovalent lithium in the crystallographic positions M2 and M1, respectively, and to the formation of new centers of divalent chromium. The structure and magnetic properties of the new centers have been discussed.
NASA Astrophysics Data System (ADS)
Caliskan, Betul; Caliskan, Ali Cengiz
2017-06-01
Bis(cyclopentadienyl)zirconium dichloride (BCZD; zirconocene dichloride) single crystals were exposed to 60Co-γ irradiation at room temperature. The irradiated single crystals were investigated between 125 and 470 K by electron paramagnetic resonance spectroscopy. The spectra of the crystals were found to be temperature independent. The paramagnetic center was attributed to the cyclopentadienyl radical. The g values of the radiation damage center observed in BCZD single crystal and the hyperfine structure constants of the free electron with nearby protons were obtained.
Vacancy-impurity centers in diamond: prospects for synthesis and applications
NASA Astrophysics Data System (ADS)
Ekimov, E. A.; Kondrin, M. V.
2017-06-01
The bright luminescence of impurity-vacancy complexes, combined with high chemical and radiation resistance, makes diamond an attractive platform for the production of single-photon emitters and luminescent biomarkers for applications in nanoelectronics and medicine. Two representatives of this kind of defects in diamond, silicon-vacancy (SiV) and germanium-vacancy (GeV) centers, are discussed in this review; their similarities and differences are demonstrated in terms of the more thoroughly studied nitrogen-vacancy (NV) complexes. The recent discovery of GeV luminescent centers opens a unique opportunity for the controlled synthesis of single-photon emitters in nanodiamonds. We demonstrate prospects for the high-pressure high-temperature (HPHT) technique to create single-photon emitters, not only as an auxiliary to chemical vapor deposition (CVD) and ion-implantation methods but also as a primary synthesis tool for producing color centers in nanodiamonds. Besides practical applications, comparative studies of these two complexes, which belong to the same structural class of defects, have a fundamental importance for deeper understanding of shelving levels, the electronic structure, and optical properties of these centers. In conclusion, we discuss several open problems regarding the structure, charge state, and practical application of these centers, which still require a solution.
Jamshaid, Anila; Ather, M Hammad; Hussain, Ghazi; Khawaja, Karim B
2008-11-01
This study compared the efficacy and safety profile of electrohydraulic (EH) and electromagnetic (EM) lithotriptors in the treatment of 10- to 20-mm renal and proximal ureteric stones at a single center and by a single operator. Between January 2001 and December 2006, we sequentially treated patients meeting study inclusion criteria with MPL 9000 Dornier EH for the first 3 years, followed by the EM Siemens Modularis shockwave lithotripsy (SWL) unit. A single operator performed all SWL treatments under the supervision of an admitting urologist. We analyzed the demographic features and stone- and treatment-related parameters including complications for both groups. In each group, the stone-free rate and efficiency quotient was determined at 1-3 months. Of 274 patients, we sequentially treated 112 using the EH lithotriptor, and 162 the EM lithotriptor. The pre-SWL patients and stone-related parameters were similar in the two groups, except for diagnostic imaging modalities. The mean number of SWL sessions, need for ancillary procedure, retreatment rate, stone location, stone-free rate, and efficiency quotient were not significantly different between groups. The mean number of shockwaves required for complete fragmentation was 2977 and 6044 (P < .000) for the EH and EM groups, respectively. Single center, single operator experience with two types of lithotriptor indicated that both are equally efficacious, with similar safety profiles. The only significant difference was that the EH lithotriptor required fewer shockwaves for fragmentation.
Alexander, Paul E; Bonner, Ashley J; Agarwal, Arnav; Li, Shelly-Anne; Hariharan, Abishek; Izhar, Zain; Bhatnagar, Neera; Alba, Carolina; Akl, Elie A; Fei, Yutong; Guyatt, Gordon H; Beyene, Joseph
2016-06-01
Prior studies regarding whether single-center trial estimates are larger than multi-center are equivocal. We examined the extent to which single-center trials yield systematically larger effects than multi-center trials. We searched the 119 core clinical journals and the Cochrane Database of Systematic Reviews for meta-analyses (MAs) of randomized controlled trials (RCTs) published during 2012. In this meta-epidemiologic study, for binary variables, we computed the pooled ratio of ORs (RORs), and for continuous outcomes mean difference in standardized mean differences (SMDs), we conducted weighted random-effects meta-regression and random-effects MA modeling. Our primary analyses were restricted to MAs that included at least five RCTs and in which at least 25% of the studies used each of single trial center (SC) and more trial center (MC) designs. We identified 81 MAs for the odds ratio (OR) and 43 for the SMD outcome measures. Based on our analytic plan, our primary analysis (core) is based on 25 MAs/241 RCTs (binary outcome) and 18 MAs/173 RCTs (continuous outcome). Based on the core analysis, we found no difference in magnitude of effect between SC and MC for binary outcomes [RORs: 1.02; 95% confidence interval (CI): 0.83, 1.24; I(2) 20.2%]. Effect sizes were systematically larger for SC than MC for the continuous outcome measure (mean difference in SMDs: -0.13; 95% CI: -0.21, -0.05; I(2) 0%). Our results do not support prior findings of larger effects in SC than MC trials addressing binary outcomes but show a very similar small increase in effect in SC than MC trials addressing continuous outcomes. Authors of systematic reviews would be wise to include all trials irrespective of SC vs. MC design and address SC vs. MC status as a possible explanation of heterogeneity (and consider sensitivity analyses). Copyright © 2015 Elsevier Inc. All rights reserved.
Coherent control of a single nitrogen-vacancy center spin in optically levitated nanodiamond
Pettit, Robert M.; Neukirch, Levi Patrick; Zhang, Yi; ...
2017-05-12
Here, we report the first observation, to the best of our knowledge, of electron spin transients in single negatively charged nitrogen-vacancy (NV -) centers, contained within optically trapped nanodiamonds, in both atmospheric pressure and low vacuum. It is shown that, after an initial exposure to low vacuum, the trapped nanodiamonds remain at temperatures near room temperature even in low vacuum. Furthermore, the transverse coherence time of the NV - center spin, measured to be T 2=101.4 ns, is robust over the range of trapping powers considered in this study.
ERIC Educational Resources Information Center
Phipps, Christa Brown
2017-01-01
Low income male preschoolers with externalizing behaviors have continued behavior issues throughout elementary school, middle school, high school, and into adulthood and create stress for their teachers. Because of this, it is important to detect externalizing behaviors early and implement an appropriate intervention. A single subject reversal…
Agarwal, Rolly S; Agarwal, Jatin; Jain, Pradeep; Chandra, Anil
2015-05-01
The ability of an endodontic instrument to remain centered in the root canal system is one of the most important characteristic influencing the clinical performance of a particular file system. Thus, it is important to assess the canal centering ability of newly introduced single file systems before they can be considered a viable replacement of full-sequence rotary file systems. The aim of the study was to compare the canal transportation, centering ability, and time taken for preparation of curved root canals after instrumentation with single file systems One Shape and Wave One, using cone-beam computed tomography (CBCT). Sixty mesiobuccal canals of mandibular molars with an angle of curvature ranging from 20(o) to 35(o) were divided into three groups of 20 samples each: ProTaper PT (group I) - full-sequence rotary control group, OneShape OS (group II)- single file continuous rotation, WaveOne WO - single file reciprocal motion (group III). Pre instrumentation and post instrumentation three-dimensional CBCT images were obtained from root cross-sections at 3mm, 6mm and 9mm from the apex. Scanned images were then accessed to determine canal transportation and centering ability. The data collected were evaluated using one-way analysis of variance (ANOVA) with Tukey's honestly significant difference test. It was observed that there were no differences in the magnitude of transportation between the rotary instruments (p >0.05) at both 3mm as well as 6mm from the apex. At 9 mm from the apex, Group I PT showed significantly higher mean canal transportation and lower centering ability (0.19±0.08 and 0.39±0.16), as compared to Group II OS (0.12±0.07 and 0.54±0.24) and Group III WO (0.13±0.06 and 0.55±0.18) while the differences between OS and WO were not statistically significant. It was concluded that there was minor difference between the tested groups. Single file systems demonstrated average canal transportation and centering ability comparable to full sequence Protaper system in curved root canals.
NASA Technical Reports Server (NTRS)
Freeman, D. C., Jr.; Powell, R. W.
1979-01-01
Aft center-of-gravity locations dictated by the large number of rocket engines required has been a continuing problem of single-stage-to-orbit vehicles. Recent work at Langley has demonstrated that these aft center-of-gravity problems become more pronounced for the proposed heavy-lift mission, creating some unique design problems for both the SSTO and staged vehicle systems. During the course of this study, an effort was made to bring together automated vehicle design, wind-tunnel tests, and flight control analyses to assess the impact of longitudinal and lateral-directional instability, and control philosophy on entry vehicle design technology.
NASA Astrophysics Data System (ADS)
Volz, T.; Schwaiger, R.; Wang, J.; Weygand, S. M.
2018-05-01
Tungsten is a promising material for plasma facing components in future nuclear fusion reactors. In the present work, we numerically investigate the deformation behavior of unirradiated tungsten (a body-centered cubic (bcc) single crystal) underneath nanoindents. A finite element (FE) model is presented to simulate wedge indentation. Crystal plasticity finite element (CPFE) simulations were performed for face-centered and body-centered single crystals accounting for the slip system family {110} <111> in the bcc crystal system and the {111} <110> slip family in the fcc system. The 90° wedge indenter was aligned parallel to the [1 ¯01 ]-direction and indented the crystal in the [0 1 ¯0 ]-direction up to a maximum indentation depth of 2 µm. In both, the fcc and bcc single crystals, the activity of slip systems was investigated and compared. Good agreement with the results from former investigations on fcc single crystals was observed. Furthermore, the in-plane lattice rotation in the material underneath an indent was determined and compared for the fcc and bcc single crystals.
Perspectives: When the Centers Do Not Hold
ERIC Educational Resources Information Center
Rosen, Lawrence
2010-01-01
During the last twenty years or so, the number of endowed centers at many universities has increased enormously--to as many as fifty or more at a single institution. There are centers for every region (or sub-region) of the world and every ethnic/religious group (or sub-group) known to history. There are centers for the study of illness and…
Finding a Child Care Solution for the Single Parent during Mobilization.
1987-04-01
Major Taylor is currently a student at the Air Command and Staff College. Major Taylor has masters degrees in business management and international...center family day care centers are especially applicable to the needs of the PRO" single parent during mobility. Recommendations of the study are to...recommended to implement family day care as soon as possible. 20. DISTRISUTION/AVAILASILITY OF AB3STRACT 21 ABSTRACT SECURITY CLASSIFICATION
NASA Astrophysics Data System (ADS)
Caliskan, Betul; Caliskan, Ali Cengiz; Er, Emine
2017-09-01
Succinic anhydride single crystals were exposed to 60Co-gamma irradiation at room temperature. The irradiated single crystals were investigated at 125 K by Electron Paramagnetic Resonance (EPR) Spectroscopy. The investigation of EPR spectra of irradiated single crystals of succinic anhydride showed the presence of two succinic anhydride anion radicals. The anion radicals observed in gamma-irradiated succinic anhydride single crystal were created by the scission of the carbon-oxygen double bond. The structure of EPR spectra demonstrated that the hyperfine splittings arise from the same radical species. The reduction of succinic anhydride was identified which is formed by the addition of an electron to oxygen of the Csbnd O bond. The g values, the hyperfine structure constants and direction cosines of the radiation damage centers observed in succinic anhydride single crystal were obtained.
Color center annealing and ageing in electron and ion-irradiated yttria-stabilized zirconia
NASA Astrophysics Data System (ADS)
Costantini, Jean-Marc; Beuneu, François
2005-04-01
We have used X-band electron paramagnetic resonance (EPR) measurements at room-temperature (RT) to study the thermal annealing and RT ageing of color centers induced in yttria-stabilized zirconia (YSZ), i.e. ZrO2:Y with 9.5 mol% Y2O3, by swift electron and ion-irradiations. YSZ single crystals with the <1 0 0> orientation were irradiated with 2.5 MeV electrons, and implanted with 100 MeV 13C ions. Electron and ion beams produce the same two color centers, namely an F+-type center (singly ionized oxygen vacancy) and the so-called T-center (Zr3+ in a trigonal oxygen local environment) which is also produced by X-ray irradiations. Isochronal annealing was performed in air up to 973 K. For both electron and ion irradiations, the defect densities are plotted versus temperature or time at various fluences. The influence of a thermal treatment at 1373 K of the YSZ single crystals under vacuum prior to the irradiations was also investigated. In these reduced samples, color centers are found to be more stable than in as-received samples. Two kinds of recovery processes are observed depending on fluence and heat treatment.
DOT National Transportation Integrated Search
2010-12-01
The purpose of this qualitative case study was to identify the types of obstacles and patterns experienced by a single heavy rail transit agency located in North America that embedded a Reliability Centered Maintenance (RCM) Process. The outcome of t...
NASA Technical Reports Server (NTRS)
Hepler, A. K.; Zeck, H.; Walker, W. H.; Polack, A.
1982-01-01
Control requirements of Controlled Configured Design Approach vehicles with far-aft center of gravity locations are studied. The baseline system investigated is a fully reusable vertical takeoff/horizontal landing single stage-to-orbit vehicle with mission requirements similar to that of the space shuttle vehicle. Evaluations were made to determine dynamic stability boundaries, time responses, trim control, operational center-of-gravity limits, and flight control subsystem design requirements. Study tasks included a baseline vehicle analysis, an aft center of gravity study, a payload size study, and a technology assessment.
34 CFR 656.4 - What types of Centers receive grants?
Code of Federal Regulations, 2010 CFR
2010-07-01
...? The Secretary awards grants to Centers that— (a) Focus on— (1) A single country or on a world area... the country or area; or (2) International studies or the international aspects of contemporary issues...
Agarwal, Jatin; Jain, Pradeep; Chandra, Anil
2015-01-01
Background The ability of an endodontic instrument to remain centered in the root canal system is one of the most important characteristic influencing the clinical performance of a particular file system. Thus, it is important to assess the canal centering ability of newly introduced single file systems before they can be considered a viable replacement of full-sequence rotary file systems. Aim The aim of the study was to compare the canal transportation, centering ability, and time taken for preparation of curved root canals after instrumentation with single file systems One Shape and Wave One, using cone-beam computed tomography (CBCT). Materials and Methods Sixty mesiobuccal canals of mandibular molars with an angle of curvature ranging from 20o to 35o were divided into three groups of 20 samples each: ProTaper PT (group I) – full-sequence rotary control group, OneShape OS (group II)- single file continuous rotation, WaveOne WO – single file reciprocal motion (group III). Pre instrumentation and post instrumentation three-dimensional CBCT images were obtained from root cross-sections at 3mm, 6mm and 9mm from the apex. Scanned images were then accessed to determine canal transportation and centering ability. The data collected were evaluated using one-way analysis of variance (ANOVA) with Tukey’s honestly significant difference test. Results It was observed that there were no differences in the magnitude of transportation between the rotary instruments (p >0.05) at both 3mm as well as 6mm from the apex. At 9 mm from the apex, Group I PT showed significantly higher mean canal transportation and lower centering ability (0.19±0.08 and 0.39±0.16), as compared to Group II OS (0.12±0.07 and 0.54±0.24) and Group III WO (0.13±0.06 and 0.55±0.18) while the differences between OS and WO were not statistically significant Conclusion It was concluded that there was minor difference between the tested groups. Single file systems demonstrated average canal transportation and centering ability comparable to full sequence Protaper system in curved root canals. PMID:26155551
The Savage Origins of Child-Centered Pedagogy, 1871-1913
ERIC Educational Resources Information Center
Fallace, Thomas
2015-01-01
Child-centered pedagogy is at the ideological core of progressive education. The simple idea that the child rather than the teacher or textbook should be the major focus of the classroom is, perhaps, the single most enduring educational idea of the era. In this historical study, the author argues that child-centered education emerged directly from…
Enhancing Cultural Adaptation through Friendship Training: A Single-Case Study.
ERIC Educational Resources Information Center
Liu, Yi-Ching; Baker, Stanley B.
1993-01-01
Four-year-old girl from mainland China experienced culture shock when attending American university day-care center. Counseling intern from Taiwan designed friendship training program based on assumptions concerning adaptation, acculturation, and peer relationships. Evaluated as intensive single-case study, findings indicated the program may be…
Rubin, Samuel J; Kirke, Diana N; Ezzat, Waleed H; Truong, Minh T; Salama, Andrew R; Jalisi, Scharukh
Determine whether marital status is a significant predictor of survival in human papillomavirus-positive oropharyngeal cancer. A single center retrospective study included patients diagnosed with human papilloma virus-positive oropharyngeal cancer at Boston Medical Center between January 1, 2010 and December 30, 2015, and initiated treatment with curative intent at Boston Medical Center. Demographic data and tumor-related variables were recorded. Univariate analysis was performed using a two-sample t-test, chi-squared test, Fisher's exact test, and Kaplan Meier curves with a log rank test. Multivariate survival analysis was performed using a Cox regression model. A total of 65 patients were included in the study with 24 patients described as married and 41 patients described as single. There was no significant difference in most demographic variables or tumor related variables between the two study groups, except single patients were significantly more likely to have government insurance (p=0.0431). Furthermore, there was no significant difference in 3-year overall survival between married patients and single patients (married=91.67% vs single=87.80%; p=0.6532) or 3-year progression free survival (married=79.17% vs single=85.37%; p=0.8136). After adjusting for confounders including age, sex, race, insurance type, smoking status, treatment, and AJCC combined pathologic stage, marital status was not a significant predictor of survival [HR=0.903; 95% CI (0.126,6.489); p=0.9192]. Although previous literature has demonstrated that married patients with head and neck cancer have a survival benefit compared to single patients with head and neck cancer, we were unable to demonstrate the same survival benefit in a cohort of patients with human papilloma virus-positive oropharyngeal cancer. Copyright © 2017 Elsevier Inc. All rights reserved.
Comparison of postural stability between injured and uninjured ballet dancers.
Lin, Cheng-Feng; Lee, I-Jung; Liao, Jung-Hsien; Wu, Hong-Wen; Su, Fong-Chin
2011-06-01
Ballet movements require a limited base of support; thus, ballet dancers require a high level of postural control. However, postural stability in ballet dancers is still unclear and needs to be understood. To evaluate ballet dancers' postural stability in performing single-leg standing, the en pointe task, and the first and fifth positions and to determine differences in task performance among healthy nondancers, healthy dancers, and dancers with ankle sprains. Controlled laboratory study. Injured dancers, uninjured dancers, and nondancers were recruited for this study (N = 33 age-matched participants; n= 11 per group). The tasks tested were single-leg standing with eyes open and closed, first position, fifth position, and en pointe. Center of pressure parameters were calculated from the ground-reaction force collected with 1 force plate. Analysis of variance was used to assess the differences of center of pressure parameters among 3 groups in single-leg standing; independent t test was used to examine the differences of center of pressure parameters between injured and uninjured dancers. During single-leg standing, injured dancers had significantly greater maximum displacement in the medial-lateral direction and total trajectory of center of pressure, compared with the uninjured dancers and nondancers. During the first and fifth positions, the injured dancers demonstrated significantly greater standard deviation of center of pressure position in the medial-lateral and anterior-posterior directions, compared with the uninjured dancers. During en pointe, the injured dancers had significantly greater maximum displacement in the medial-lateral direction and the anterior-posterior direction, compared with the uninjured dancers. The injured and uninjured dancers demonstrated differences in postural stability in the medial-lateral direction during single-leg standing and the ballet postures. Although the injured dancers received ballet training, their postural stability may still be inferior to that of the nondancers. This study is a first step in understanding that injured ballet dancers do not have the same postural stability as uninjured dancers and that it is even inferior to that of nondancers, which is important to understand for further study on rehabilitation. The future development of effective balance training programs for ballet dancers with ankle injuries should emphasize improvements in medial-lateral directional balance.
Stevens, Dennis C; Helseth, Carol C; Khan, M Akram; Munson, David P; Reid, E J
2011-01-01
The purpose of this research was to test the hypothesis that parental satisfaction with neonatal intensive care is greater in a single-family room facility as compared with a conventional open-bay neonatal intensive care unit (NICU). This investigation was a prospective cohort study comparing satisfaction survey results for parents who responded to a commercially available parent NICU satisfaction survey following the provision of NICU care in open-bay and single-family room facilities. A subset of 16 items indicative of family-centered care was also computed and compared for these two NICU facilities. Parents whose babies received care in the single-family room facility expressed significantly improved survey responses in regard to the NICU environment, overall assessment of care, and total survey score than did parents of neonates in the open-bay facility. With the exception of the section on nursing in which scores in both facilities were high, nonsignificant improvement in median scores for the sections on delivery, physicians, discharge planning, and personal issues were noted. The total median item score for family-centered care was significantly greater in the single-family room than the open-bay facility. Parental satisfaction with care in the single-family room NICU was improved in comparison with the traditional open-bay NICU. The single-family room environment appears more conducive to the provision of family-centered care. Improved parental satisfaction with care and the potential for enhanced family-centered care need to be considered in decisions made regarding the configuration of NICU facilities in the future.
Problems of Eskimo Relocation for Industrial Employment. A Preliminary Study.
ERIC Educational Resources Information Center
Stevenson, D. S.
A study was conducted to determine the reasons for variable success in relocating Eskimo families from rural areas of the northern territories of Canada to southern centers of industrial employment (railways, mining centers). The data were collected by interviewing 105 Eskimos, both male and female, married and single, who had migrated south. The…
NASA Astrophysics Data System (ADS)
Fathy, Adel; Ghamry, Essam
2017-03-01
Though the Equatorial Ionospheric Anomaly (EIA) is represented by two crests within ±15° latitude, a single crest is also observed in the entire ionosphere. Few studies have addressed single crest phenomena. A statistical study of 2237 single crest phenomenon from the in situ electron density measurements of Swarm A satellite was investigated during December 2013-December 2015. Our analysis focused on local time, seasonal, and both geographic and geomagnetic latitudinal variations. Our results show the following observations: 1 - The maximum number of events peaks mainly in the dayside region around 0800-1200 LT and these occur mainly within the magnetic equator. 2 - The maximum amplitude of the single crests take place most prominently during equinoxes. 3 - The majority of single crests occur in the northern hemisphere. 4 - The seasonal distribution of the events shows that the summer events are located further from the magnetic equator in the northern hemisphere and shift their locations into the southern hemisphere in winter, while spring events are centered along the magnetic equator. 5 - Dayside single crest events appear close to the magnetic equator and more centered on the equator in winter season. 6 - Dawn, night and dusk side events reverse their location from northern hemisphere in summer to southern hemisphere in winter.
Faklaris, Orestis; Garrot, Damien; Joshi, Vandana; Druon, Frédéric; Boudou, Jean-Paul; Sauvage, Thierry; Georges, Patrick; Curmi, Patrick A; Treussart, François
2008-12-01
Diamond nanoparticles are promising photoluminescent probes for tracking intracellular processes, due to embedded, perfectly photostable color centers. In this work, the spontaneous internalization of such nanoparticles (diameter 25 nm) in HeLa cancer cells is investigated by confocal microscopy and time-resolved techniques. Nanoparticles are observed inside the cell cytoplasm at the single-particle and single-color-center level, assessed by time-correlation intensity measurements. Improvement of the nanoparticle signal-to-noise ratio inside the cell is achieved using a pulsed-excitation laser and time-resolved detection taking advantage of the long radiative lifetime of the color-center excited state as compared to cell autofluorescence. The internalization pathways are also investigated, with endosomal marking and colocalization analyses. The low colocalization ratio observed proves that nanodiamonds are not trapped in endosomes, a promising result in prospect of drug delivery by these nanoparticles. Low cytotoxicity of these nanoparticles in this cell line is also shown.
Correlates of Living Alone among Single Elderly Chinese Immigrants in Canada
ERIC Educational Resources Information Center
Lai, Daniel W. L.; Leonenko, Wendy L.
2007-01-01
According to traditional Chinese culture, families will care for their elderly. Therefore, it appears to be uncommon for elderly Chinese to live alone. This study examines the correlates for single elderly Chinese immigrants in Canada to live alone. Using a probability sample of single elderly Chinese immigrants (N = 660) in seven urban centers,…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Xufan; Budai, John D.; Liu, Feng
2013-01-01
Phosphor-converted white light-emitting diodes for indoor illumination need to be warm-white (i.e., correlated color temperature <4000 K) with good color rendition (i.e., color rendering index >80). However, no single-phosphor, single-emitting-center-converted white light-emitting diodes can simultaneously satisfy the color temperature and rendition requirements due to the lack of sufficient red spectral component in the phosphors’ emission spectrum. Here, we report a new yellow Ba 0.93Eu 0.07Al 2O 4 phosphor that has a new orthorhombic lattice structure and exhibits a broad yellow photoluminescence band with sufficient red spectral component. Warm-white emissions with correlated color temperature <4000 K and color rendering index >80more » were readily achieved when combining the Ba 0.93Eu 0.07Al 2O 4 phosphor with a blue light-emitting diode (440–470 nm). This study demonstrates that warm-white light-emitting diodes with high color rendition (i.e., color rendering index >80) can be achieved based on single-phosphor, single-emitting-center conversion.« less
Single-bubble and multibubble cavitation in water triggered by laser-driven focusing shock waves
NASA Astrophysics Data System (ADS)
Veysset, D.; Gutiérrez-Hernández, U.; Dresselhaus-Cooper, L.; De Colle, F.; Kooi, S.; Nelson, K. A.; Quinto-Su, P. A.; Pezeril, T.
2018-05-01
In this study a single laser pulse spatially shaped into a ring is focused into a thin water layer, creating an annular cavitation bubble and cylindrical shock waves: an outer shock that diverges away from the excitation laser ring and an inner shock that focuses towards the center. A few nanoseconds after the converging shock reaches the focus and diverges away from the center, a single bubble nucleates at the center. The inner diverging shock then reaches the surface of the annular laser-induced bubble and reflects at the boundary, initiating nucleation of a tertiary bubble cloud. In the present experiments, we have performed time-resolved imaging of shock propagation and bubble wall motion. Our experimental observations of single-bubble cavitation and collapse and appearance of ring-shaped bubble clouds are consistent with our numerical simulations that solve a one-dimensional Euler equation in cylindrical coordinates. The numerical results agree qualitatively with the experimental observations of the appearance and growth of large bubble clouds at the smallest laser excitation rings. Our technique of shock-driven bubble cavitation opens interesting perspectives for the investigation of shock-induced single-bubble or multibubble cavitation phenomena in thin liquids.
ERIC Educational Resources Information Center
Brackin, Mike
2012-01-01
A single qualitative case study design was used to determine the opinions of administrators and faculty from a community college that is considered to be transitioning to a learning-centered college. The researcher conducted the case study to describe, explain, and evaluate the phenomenon. The researcher also recorded facilitators or roadblocks…
Curriculum and Assessment Policies and Practices in a Day Treatment Center in North Carolina
ERIC Educational Resources Information Center
Ferrell, Kimberly Ann
2013-01-01
The purpose of this qualitative single case study was to describe current instructional policies and practices in a one-day treatment center in North Carolina for students with emotional and behavioral disorders (EBD). The following research questions guided the study: (1) What are the curriculum policies, practices, and philosophies of day…
Baffelli, Renata; Notarangelo, Lucia D; Imberti, Luisa; Hershfield, Michael S; Serana, Federico; Santisteban, Ines; Bolda, Federica; Porta, Fulvio; Lanfranchi, Arnalda
2015-10-01
We carried out a retrospective analysis of 27 patients with Adenosine Deaminase (ADA) deficiency diagnosed in a single center from 1997 to the 2013, for evaluating whether data regarding types of disease-inducing mutations, biochemical and immunological features as well as clinical outcomes of patients treated with enzyme replacement or transplantation, were comparable to those obtained in multicenter studies. The ADA deficiency diagnosis was performed with biochemical, immunological and molecular techniques. Ten patients treated with hematopoietic stem cell transplantation and three in treatment with enzyme replacement were followed up in our center. Twenty-four different mutations were identified and five were not previously reported. Identical mutations were found among patients from the same Romani ethnic group or from the same geographical region. A more rapid recovery was observed in enzyme replacement treated patients in comparison with those transplanted that, however, showed a continuous and long-lasting improvement both in terms of immune and metabolic recovery. The data obtained in our single center are comparable with those that have been reported in multicenter surveys.
Phonon Self-Energy Corrections to Nonzero Wave-Vector Phonon Modes in Single-Layer Graphene
NASA Astrophysics Data System (ADS)
Araujo, P. T.; Mafra, D. L.; Sato, K.; Saito, R.; Kong, J.; Dresselhaus, M. S.
2012-07-01
Phonon self-energy corrections have mostly been studied theoretically and experimentally for phonon modes with zone-center (q=0) wave vectors. Here, gate-modulated Raman scattering is used to study phonons of a single layer of graphene originating from a double-resonant Raman process with q≠0. The observed phonon renormalization effects are different from what is observed for the zone-center q=0 case. To explain our experimental findings, we explored the phonon self-energy for the phonons with nonzero wave vectors (q≠0) in single-layer graphene in which the frequencies and decay widths are expected to behave oppositely to the behavior observed in the corresponding zone-center q=0 processes. Within this framework, we resolve the identification of the phonon modes contributing to the G⋆ Raman feature at 2450cm-1 to include the iTO+LA combination modes with q≠0 and also the 2iTO overtone modes with q=0, showing both to be associated with wave vectors near the high symmetry point K in the Brillouin zone.
Wu, Zhenggang; Gao, Y. F.; Bei, Hongbin
2015-07-25
To understand the fundamental deformation mechanisms of compositionally complex alloys, single crystals of a multi-component equiatomic FeNiCoCr alloy with face-centered cubic (FCC) structure were grown for mechanical studies. Similarly to typical FCC pure metals, slip trace analyses indicate that dislocation slips take place on (1 1 1) planes along [11¯0] directions. The critical resolved shear stress (CRSS) obeys the Schmid law at both 77 and 293 K, and tension–compression asymmetry is not observed. Although this material slips in a normal FCC manner both at 293 and 77 K, compared to typical FCC metals the CRSS’s strong temperature dependence is abnormal.
Paramagnetic resonance of LaGaO3: Mn single crystals grown by floating zone melting
NASA Astrophysics Data System (ADS)
Vazhenin, V. A.; Potapov, A. P.; Artyomov, M. Yu.; Salosin, M. A.; Fokin, A. V.; Gil'mutdinov, I. F.; Mukhamedshin, I. R.
2016-02-01
The EPR spectrum of Mn-doped lanthanum gallate single crystals grown by floating zone melting with optical heating has been studied. In contrast to the crystals grown according to the Czochralski method, no manganese is found in these crystals even after high-temperature annealing in air. The spectral characteristics of Fe3+ and Gd3+ centers in crystals prepared by various methods have been compared in the rhombohedral phase, and the fourth-rank nondiagonal parameters of the Fe3+ trigonal centers have been determined, as well.
Biological Information Processing in Single Microtubules
2014-03-05
single Microtubule Google Mountain view campus, workshop on quantum biology 22 October 2010 3. Paul Davies Beyond Center at Arizona State University...Phoenix) Phoenix, workshop on quantum biology and cancer research, Experimental studies on single microtubule, 25-27 October 2010, Tempe, Arizona...State University, USA 4. Quantum aspects of microtubule: Direct experimental evidence for the existence of quantum states in microtubule, Towards a
34 CFR 656.23 - What priorities may the Secretary establish?
Code of Federal Regulations, 2010 CFR
2010-07-01
... POSTSECONDARY EDUCATION, DEPARTMENT OF EDUCATION NATIONAL RESOURCE CENTERS PROGRAM FOR FOREIGN LANGUAGE AND AREA... priorities: (1) Specific countries or world areas, such as, for example, East Asia, Africa, or the Middle East. (2) Specific focus of a Center, such as, for example, a single world area; international studies...
Relaxometry and Dephasing Imaging of Superparamagnetic Magnetite Nanoparticles Using a Single Qubit.
Schmid-Lorch, Dominik; Häberle, Thomas; Reinhard, Friedemann; Zappe, Andrea; Slota, Michael; Bogani, Lapo; Finkler, Amit; Wrachtrup, Jörg
2015-08-12
To study the magnetic dynamics of superparamagnetic nanoparticles, we use scanning probe relaxometry and dephasing of the nitrogen vacancy (NV) center in diamond, characterizing the spin noise of a single 10 nm magnetite particle. Additionally, we show the anisotropy of the NV sensitivity's dependence on the applied decoherence measurement method. By comparing the change in relaxation (T1) and dephasing (T2) time in the NV center when scanning a nanoparticle over it, we are able to extract the nanoparticle's diameter and distance from the NV center using an Ornstein-Uhlenbeck model for the nanoparticle's fluctuations. This scanning probe technique can be used in the future to characterize different spin label substitutes for both medical applications and basic magnetic nanoparticle behavior.
Relaxometry and Dephasing Imaging of Superparamagnetic Magnetite Nanoparticles Using a Single Qubit
NASA Astrophysics Data System (ADS)
Schmid-Lorch, Dominik; Häberle, Thomas; Reinhard, Friedemann; Zappe, Andrea; Slota, Michael; Bogani, Lapo; Finkler, Amit; Wrachtrup, Jörg
2015-08-01
To study the magnetic dynamics of superparamagnetic nanoparticles we use scanning probe relaxometry and dephasing of the nitrogen-vacancy (NV) center in diamond, characterizing the spin-noise of a single 10-nm magnetite particle. Additionally, we show the anisotropy of the NV sensitivity's dependence on the applied decoherence measurement method. By comparing the change in relaxation (T 1 ) and dephasing (T 2 ) time in the NV center when scanning a nanoparticle over it, we are able to extract the nanoparticle's diameter and distance from the NV center using an Ornstein-Uhlenbeck model for the nanoparticle's fluctuations. This scanning-probe technique can be used in the future to characterize different spin label substitutes for both medical applications and basic magnetic nanoparticle behavior.
Hodel, Sandro; Seeli, Franziska; Fuchs, Bruno
2015-06-17
Retrospective analysis of presentation, diagnosis and outcome of patients with osteosarcoma, chondrosarcoma and Ewing's sarcoma was performed for a single Sarcoma Center in Zurich at the University Hospital Balgrist. 201 patients were included. Overall survival at five and ten years were 74 ± 6%, 69 ± 7% for osteosarcoma (n = 85, since 2000), 85 ± 7%, 80 ± 9% for Ewing's sarcoma (n = 43, since 1990) and 86 ± 5%, 78 ± 9% for chondrosarcoma (n = 73, since 2000). The here presented overall survival rates from a single Sarcoma Center in Switzerland appear to be equivalent to other large international monocenter studies. The presentation and epidemiology of these patients are in accordance with large multicenter epidemiological studies. A nationwide sarcoma database (SwissSARCOS; www.sarcoma.ch) seems indispensable for more detailed analysis and quality management in such rare diseases.
ERIC Educational Resources Information Center
Rondeau, Ann E.
2010-01-01
This dissertation touches on a series of events leading to an aspect of United States public policy dealing with weapons of mass destruction (WMD). After exploring the literature that describes the understanding of public policy, this paper uses the case study method to understand why and how a single research center and a particular set of…
Employer-Sponsored Child Care Models and Related Issues.
ERIC Educational Resources Information Center
Renfroe, Martha Lou
This study was designed to describe the different models of Employer-Sponsored Child Care (ESCC) available to employers and child care professionals. Examples of specific child care programs sponsored by employers are described, and five ESCC models are identified: on-site and off-site centers for a single employer, off-site centers for multiple…
Single-dose volume regulation algorithm for a gas-compensated intrathecal infusion pump.
Nam, Kyoung Won; Kim, Kwang Gi; Sung, Mun Hyun; Choi, Seong Wook; Kim, Dae Hyun; Jo, Yung Ho
2011-01-01
The internal pressures of medication reservoirs of gas-compensated intrathecal medication infusion pumps decrease when medication is discharged, and these discharge-induced pressure drops can decrease the volume of medication discharged. To prevent these reductions, the volumes discharged must be adjusted to maintain the required dosage levels. In this study, the authors developed an automatic control algorithm for an intrathecal infusion pump developed by the Korean National Cancer Center that regulates single-dose volumes. The proposed algorithm estimates the amount of medication remaining and adjusts control parameters automatically to maintain single-dose volumes at predetermined levels. Experimental results demonstrated that the proposed algorithm can regulate mean single-dose volumes with a variation of <3% and estimate the remaining medication volume with an accuracy of >98%. © 2010, Copyright the Authors. Artificial Organs © 2010, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Quantum Properties of Dichroic Silicon Vacancies in Silicon Carbide
NASA Astrophysics Data System (ADS)
Nagy, Roland; Widmann, Matthias; Niethammer, Matthias; Dasari, Durga B. R.; Gerhardt, Ilja; Soykal, Öney O.; Radulaski, Marina; Ohshima, Takeshi; Vučković, Jelena; Son, Nguyen Tien; Ivanov, Ivan G.; Economou, Sophia E.; Bonato, Cristian; Lee, Sang-Yun; Wrachtrup, Jörg
2018-03-01
Although various defect centers have displayed promise as either quantum sensors, single photon emitters, or light-matter interfaces, the search for an ideal defect with multifunctional ability remains open. In this spirit, we study the dichroic silicon vacancies in silicon carbide that feature two well-distinguishable zero-phonon lines and analyze the quantum properties in their optical emission and spin control. We demonstrate that this center combines 40% optical emission into the zero-phonon lines showing the contrasting difference in optical properties with varying temperature and polarization, and a 100% increase in the fluorescence intensity upon the spin resonance, and long spin coherence time of their spin-3 /2 ground states up to 0.6 ms. These results single out this defect center as a promising system for spin-based quantum technologies.
Jacob, R Lorie; Geddes, Jonah; McCartney, Shirley; Burchiel, Kim J
2016-05-01
OBJECT The objective of this study was to compare the cost of deep brain stimulation (DBS) performed awake versus asleep at a single US academic health center and to compare costs across the University HealthSystem Consortium (UHC) Clinical Database. METHODS Inpatient and outpatient demographic and hospital financial data for patients receiving a neurostimulator lead implant (from the first quarter of 2009 to the second quarter of 2014) were collected and analyzed. Inpatient charges included those associated with International Classification of Diseases, Ninth Revision (ICD-9) procedure code 0293 (implantation or replacement of intracranial neurostimulator lead). Outpatient charges included all preoperative charges ≤ 30 days prior to implant and all postoperative charges ≤ 30 days after implant. The cost of care based on reported charges and a cost-to-charge ratio was estimated. The UHC database was queried (January 2011 to March 2014) with the same ICD-9 code. Procedure cost data across like hospitals (27 UHC hospitals) conducting similar DBS procedures were compared. RESULTS Two hundred eleven DBS procedures (53 awake and 158 asleep) were performed at a single US academic health center during the study period. The average patient age ( ± SD) was 65 ± 9 years old and 39% of patients were female. The most common primary diagnosis was Parkinson's disease (61.1%) followed by essential and other forms of tremor (36%). Overall average DBS procedure cost was $39,152 ± $5340. Asleep DBS cost $38,850 ± $4830, which was not significantly different than the awake DBS cost of $40,052 ± $6604. The standard deviation for asleep DBS was significantly lower (p ≤ 0.05). In 2013, the median cost for a neurostimulator implant lead was $34,052 at UHC-affiliated hospitals that performed at least 5 procedures a year. At Oregon Health & Science University, the median cost was $17,150 and the observed single academic health center cost for a neurostimulator lead implant was less than the expected cost (ratio 0.97). CONCLUSIONS In this single academic medical center cost analysis, DBS performed asleep was associated with a lower cost variation relative to the awake procedure. Furthermore, costs compared favorably to UHC-affiliated hospitals. While asleep DBS is not yet standard practice, this center exclusively performs asleep DBS at a lower cost than comparable institutions.
Sweis, R; Heinrich, H; Fox, M
2018-03-01
Advances in clinical measurement of esophageal motility and function have improved the assessment of swallowing disorders and reflux symptoms. Variation in data acquisition, analysis, and reporting exists and impacts on diagnosis and management. This study examined variation in esophageal manometry methodology between institutions to establish the status in current practice. A structured survey was distributed through international NGM societies using an Internet-based platform. Questions explored infrastructure, technology, analysis, and reporting. Responses were received from 91 centers from 29 countries. Eighteen (20%) centers used "conventional" manometry, 75 (82%) high-resolution manometry, and 53 (58%) HR impedance manometry. All centers documented motility for single water swallows. The Chicago Classification was applied by 65 (71.4%) centers. In contrast, analysis of EGJ morphology varied widely. Adjunctive testing was often applied: multiple rapid swallows (77%), rapid drink challenge (77%), single solid swallows (63%), and a standard test meal (18%). Of 86 (94.5%) units that offered pH impedance (pH-Z) studies, approximately half (53.5%) performed tests on acid-suppressant medication in patients with a high pretest probability (eg, erosive esophagitis). Most (75.6%) centers manually reviewed every reflux event. Others examined pH-Z data only prior to symptoms. To assess symptom association with reflux events, 73.6% centers analyzed each symptom separately, whereas 29.7% centers pooled symptoms. There is marked variation in the data acquisition, analysis, and reporting of esophageal manometry studies. Further efforts to improve quality and uniformity in testing and reporting are required. This survey provides information upon which best-practice guidelines can be developed. © 2017 John Wiley & Sons Ltd.
Su, Wei; Zhang, Yisen; Chen, Junfan; Liu, Jian; Rajah, Gary; Yang, Xinjian
2018-04-23
Background For the treatment of intracranial aneurysms, the low-profile visualized intraluminal support (LVIS) stent is a new generation of highly visible-braided stent that was recently introduced in China. Here, we report our single-center retrospective experience of safety and efficacy utilizing LVIS for stent-assisted coiling of intracranial aneurysms. Methods We included 218 patients with intracranial aneurysms consecutively treated with LVIS SR stents at our center in this study. Postoperative and follow-up embolization scores, procedural complications, clinical and angiographic findings at mid-term follow-up, as well as recurrence rate, preoperative and follow-up mRS scores were analyzed. Results Two hundred and eighteen patients with two hundred and twenty five intracranial aneurysms were enrolled. The locations and distribution were ICA (125, 55.6%), PcomA (47, 20.9%), VA (38, 16.8%), and BA (15, 6.7%). Two hundred and eighteen aneurysms were treated with the stent-assisted coiling and seven patients with LVIS stents alone. Angiographic follow-up was available for 115 (51.1%) aneurysms, 8 (7.0%) of which had recurrences including 7 (6.5%) unruptured aneurysms and 1(14.3%) ruptured aneurysm. The procedural complication rate was 2.75% in total, including distal hemorrhage (1, 0.45%; SAH), ischemic events (5, 2.3%). Conclusions Our single-center retrospective experience is one of the larger studies to date assessing the LVIS device. Compared with many laser-cut stent studies, the LVIS device had a higher aneurysm complete occlusion rate at follow-up coupled with low complication rates. However, this study was our initial experience with LVIS, larger patient numbers, and longer follow-up will be needed to fully assess the long-term efficacy of LVIS in treating intracranial aneurysms.
Family Support Center Village: A Unique Approach for Low-Income Single Women with Children
ERIC Educational Resources Information Center
Graber, Helen V.; Wolfe, Jayne L.
2004-01-01
The Family Support Center, recognizing the need for single women with children to maintain stability, has developed a program referred to as the Family Support Center Village, which incorporates a service enriched co-housing model. The "Village" will be the catalyst for these mothers' self-sufficiency and will provide opportunities to develop…
Quality of Care Assessment: The Role of Faculty at Academic Medical Centers.
ERIC Educational Resources Information Center
Brook, Robert H.
Currently, there is not a single university medical center in which an acceptable routine system to assure quality of care has been established. This may result from reliance on the structure of the medical education process as a proxy measure to assure that physicians perform appropriately in their role. Several studies have been conducted to…
Thiering, Gergő; Londero, Elisa; Gali, Adam
2014-10-21
Fluorescent nanodiamonds constitute an outstanding alternative to semiconductor quantum dots and dye molecules for in vivo biomarker applications, where the fluorescence comes from optically active point defects acting as color centers in the nanodiamonds. For practical purposes, these color centers should be photostable as a function of the laser power or the surface termination of nanodiamonds. Furthermore, they should exhibit a sharp and nearly temperature-independent zero-phonon line. In this study, we show by hybrid density functional theory calculations that nickel doped nanodiamonds exhibit the desired properties, thus opening the avenue to practical applications. In particular, harnessing the strong quantum confinement effect in molecule-sized nanodiamonds is very promising for achieving multicolor imaging by single nickel-related defects.
NASA Astrophysics Data System (ADS)
Thiering, Gergő; Londero, Elisa; Gali, Adam
2014-09-01
Fluorescent nanodiamonds constitute an outstanding alternative to semiconductor quantum dots and dye molecules for in vivo biomarker applications, where the fluorescence comes from optically active point defects acting as color centers in the nanodiamonds. For practical purposes, these color centers should be photostable as a function of the laser power or the surface termination of nanodiamonds. Furthermore, they should exhibit a sharp and nearly temperature-independent zero-phonon line. In this study, we show by hybrid density functional theory calculations that nickel doped nanodiamonds exhibit the desired properties, thus opening the avenue to practical applications. In particular, harnessing the strong quantum confinement effect in molecule-sized nanodiamonds is very promising for achieving multicolor imaging by single nickel-related defects.
Novel Plasmonic Materials and Nanodevices for Integrated Quantum Photonics
NASA Astrophysics Data System (ADS)
Shalaginov, Mikhail Y.
Light-matter interaction is the foundation for numerous important quantum optical phenomena, which may be harnessed to build practical devices with higher efficiency and unprecedented functionality. Nanoscale engineering is seen as a fruitful avenue to significantly strengthen light-matter interaction and also make quantum optical systems ultra-compact, scalable, and energy efficient. This research focuses on color centers in diamond that share quantum properties with single atoms. These systems promise a path for the realization of practical quantum devices such as nanoscale sensors, single-photon sources, and quantum memories. In particular, we explored an intriguing methodology of utilizing nanophotonic structures, such as hyperbolic metamaterials, nanoantennae, and plasmonic waveguides, to improve the color centers performance. We observed enhancement in the color center's spontaneous emission rate, emission directionality, and cooperativity over a broad optical frequency range. Additionally, we studied the effect of plasmonic environments on the spin-readout sensitivity of color centers. The use of CMOS-compatible epitaxially grown plasmonic materials in the design of these nanophotonic structures promises a new level of performance for a variety of integrated room-temperature quantum devices based on diamond color centers.
NASA Astrophysics Data System (ADS)
Osipov, V. Yu.; Shames, A. I.; Efimov, N. N.; Shakhov, F. M.; Kidalov, S. V.; Minin, V. V.; Vul', A. Ya.
2018-04-01
The electron paramagnetic resonance (EPR) spectra of triplet centers in detonation nanodiamonds (DNDs) and diamond single crystals of submicrometer size, synthesized from those DNDs at high pressures and temperatures, are studied. In the EPR spectra of DNDs, signals from negatively charged nitrogen- vacancy centers (NV)/sup(-) with a g factor of g 1 = 4.24 and multivacancies with g 2 = 4.00 are observed. The signals from (NV)/sup(-) centers disappear in the spectra of diamond single crystals, and a quintet signal with g = 4.00 is detected at the position of the signal from multivacancies. Analysis of the shape and position of the quintet' lines showed that this ESR signal is due to the pairs of nitrogen substitution centers in diamond, separated from each other by distances not exceeding 0.7 nm, between which a strong exchange interaction takes place. A comparison of the experimental data and the simulation results allows determining the spin-Hamiltonian parameters of the exchange-coupled pairs of paramagnetic impurity nitrogen atoms.
NASA Astrophysics Data System (ADS)
Mysore, Abhishek Arun Babu
A medium data center consists of servers performing operations such as file sharing, collaboration and email. There are a large number of small and medium data centers across the world which consume more energy and are less efficient when compared to large data center facilities of companies such as GOOGLE, APPLE and FACEBOOK. Such companies are making their data center facilities more environmental friendly by employing renewable energy solutions such as wind and solar to power the data center or in data center cooling. This not only reduces the carbon footprint significantly but also decreases the costs incurred over a period of time. Cooling of data center play a vital role in proper functioning of the servers. It is found that cooling consumes about 50% of the total power consumed by the data center. Traditional method of cooling includes the use of mechanical compression chillers which consume lot of power and is not desirable. In order to eliminate the use of mechanical compressor chillers renewable energy resources such as solar and wind should be employed. One such technology is solar thermal cooling by means of absorption chiller which is powered by solar energy. The absorption chiller unit can be coupled with either flat plate or evacuated tube collectors in order to achieve the required inlet temperature for the generator of the absorption chiller unit. In this study a modular data center is considered having a cooling load requirement of 23kw. The performance characteristics of a single stage Lithium Bromide/ water refrigeration is presented in this study considering the cooling load of 23kw. Performance characteristics of each of the 4 heat exchangers within the unit is discussed which helps in customizing the unit according to the users' specific needs. This analysis helps in studying the importance of different properties such as the effect of inlet temperatures of hot water for generator, inlet temperatures of cooling water for absorber and condenser and outlet chilled water temperatures of the evaporator.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liebermeister, Lars, E-mail: lars.liebermeister@physik.uni-muenchen.de; Petersen, Fabian; Münchow, Asmus v.
2014-01-20
A diamond nano-crystal hosting a single nitrogen vacancy (NV) center is optically selected with a confocal scanning microscope and positioned deterministically onto the subwavelength-diameter waist of a tapered optical fiber (TOF) with the help of an atomic force microscope. Based on this nano-manipulation technique, we experimentally demonstrate the evanescent coupling of single fluorescence photons emitted by a single NV-center to the guided mode of the TOF. By comparing photon count rates of the fiber-guided and the free-space modes and with the help of numerical finite-difference time domain simulations, we determine a lower and upper bound for the coupling efficiency ofmore » (9.5 ± 0.6)% and (10.4 ± 0.7)%, respectively. Our results are a promising starting point for future integration of single photon sources into photonic quantum networks and applications in quantum information science.« less
NASA Astrophysics Data System (ADS)
Khramtsov, Igor A.; Vyshnevyy, Andrey A.; Fedyanin, Dmitry Yu.
2018-03-01
Practical applications of quantum information technologies exploiting the quantum nature of light require efficient and bright true single-photon sources which operate under ambient conditions. Currently, point defects in the crystal lattice of diamond known as color centers have taken the lead in the race for the most promising quantum system for practical non-classical light sources. This work is focused on a different quantum optoelectronic material, namely a color center in silicon carbide, and reveals the physics behind the process of single-photon emission from color centers in SiC under electrical pumping. We show that color centers in silicon carbide can be far superior to any other quantum light emitter under electrical control at room temperature. Using a comprehensive theoretical approach and rigorous numerical simulations, we demonstrate that at room temperature, the photon emission rate from a p-i-n silicon carbide single-photon emitting diode can exceed 5 Gcounts/s, which is higher than what can be achieved with electrically driven color centers in diamond or epitaxial quantum dots. These findings lay the foundation for the development of practical photonic quantum devices which can be produced in a well-developed CMOS compatible process flow.
Nakatani, Tomotaka; Yoshiasa, Akira; Nakatsuka, Akihiko; Hiratoko, Tatsuya; Mashimo, Tsutomu; Okube, Maki; Sasaki, Satoshi
2016-02-01
A variable-temperature single-crystal X-ray diffraction study of a synthetic BaTiO3 perovskite has been performed over the temperature range 298-778 K. A transition from a tetragonal (P4mm) to a cubic (Pm3m) phase has been revealed near 413 K. In the non-centrosymmetric P4mm symmetry group, both Ti and O atoms are displaced along the c-axis in opposite directions with regard to the Ba position fixed at the origin, so that Ti(4+) and Ba(2+) cations occupy off-center positions in the TiO6 and BaO12 polyhedra, respectively. Smooth temperature-dependent changes of the atomic coordinates become discontinuous with the phase transition. Our observations imply that the cations remain off-center even in the high-temperature cubic phase. The temperature dependence of the mean-square displacements of Ti in the cubic phase includes a significant static component which means that Ti atoms are statistically distributed in the off-center positions.
Samsel, R; Chmura, A; Włodarczyk, Z; Wyzgał, J; Cieciura, T; Lagiewska, B; Pliszczyński, J; Korczak, G; Lazowski, T; Paczek, L; Wałaszewski, J; Lao, M; Rowiński, W
1999-01-01
Monoclonal and polyclonal antilymphocyte antibodies have been used successfully in organ transplantation as induction therapy and in the treatment of acute graft rejection. Used for induction the medication is generally given for the first 7-10 days. The aim of this study was to assess the safety and efficacy of single high dose (9 mg/kg) ATG Fresenius S given perioperatively, before revascularization, to kidney allograft recipients. During last twelve months seventy six, first cadaveric kidney adult recipients were included into the study in two centers (center A-64, center B-12). All patients received triple drug immunosuppression (Neoral, steroids and Cellcept which was replaced by azathioprine after 4 months), and were randomized to receive ATG or not. The follow-up period ranged from 1 month up to 1 year. The preliminary results are very promising, the rejection rate in bolus group was significantly lower than in control. No significant side effects or serious adverse events in both groups were observed.
Formation mechanism of fivefold deformation twins in a face-centered cubic alloy.
Zhang, Zhenyu; Huang, Siling; Chen, Leilei; Zhu, Zhanwei; Guo, Dongming
2017-03-28
The formation mechanism considers fivefold deformation twins originating from the grain boundaries in a nanocrystalline material, resulting in that fivefold deformation twins derived from a single crystal have not been reported by molecular dynamics simulations. In this study, fivefold deformation twins are observed in a single crystal of face-centered cubic (fcc) alloy. A new formation mechanism is proposed for fivefold deformation twins in a single crystal. A partial dislocation is emitted from the incoherent twin boundaries (ITBs) with high energy, generating a stacking fault along {111} plane, and resulting in the nucleating and growing of a twin by the successive emission of partials. A node is fixed at the intersecting center of the four different slip {111} planes. With increasing stress under the indentation, ITBs come into being close to the node, leading to the emission of a partial from the node. This generates a stacking fault along a {111} plane, nucleating and growing a twin by the continuous emission of the partials. This process repeats until the formation of fivefold deformation twins.
Formation mechanism of fivefold deformation twins in a face-centered cubic alloy
NASA Astrophysics Data System (ADS)
Zhang, Zhenyu; Huang, Siling; Chen, Leilei; Zhu, Zhanwei; Guo, Dongming
2017-03-01
The formation mechanism considers fivefold deformation twins originating from the grain boundaries in a nanocrystalline material, resulting in that fivefold deformation twins derived from a single crystal have not been reported by molecular dynamics simulations. In this study, fivefold deformation twins are observed in a single crystal of face-centered cubic (fcc) alloy. A new formation mechanism is proposed for fivefold deformation twins in a single crystal. A partial dislocation is emitted from the incoherent twin boundaries (ITBs) with high energy, generating a stacking fault along {111} plane, and resulting in the nucleating and growing of a twin by the successive emission of partials. A node is fixed at the intersecting center of the four different slip {111} planes. With increasing stress under the indentation, ITBs come into being close to the node, leading to the emission of a partial from the node. This generates a stacking fault along a {111} plane, nucleating and growing a twin by the continuous emission of the partials. This process repeats until the formation of fivefold deformation twins.
A nanodiamond-tapered fiber system with high single-mode coupling efficiency.
Schröder, Tim; Fujiwara, Masazumi; Noda, Tetsuya; Zhao, Hong-Quan; Benson, Oliver; Takeuchi, Shigeki
2012-05-07
We present a fiber-coupled diamond-based single photon system. Single nanodiamonds containing nitrogen vacancy defect centers are deposited on a tapered fiber of 273 nanometer in diameter providing a record-high number of 689,000 single photons per second from a defect center in a single-mode fiber. The system can be cooled to cryogenic temperatures and coupled evanescently to other nanophotonic structures, such as microresonators. The system is suitable for integrated quantum transmission experiments, two-photon interference, quantum-random-number generation and nano-magnetometry.
Bright nanowire single photon source based on SiV centers in diamond
Marseglia, L.; Saha, K.; Ajoy, A.; ...
2018-01-01
The practical implementation of quantum technologies such as quantum commu- nication and quantum cryptography relies on the development of indistinguishable, robust, and bright single photon sources that works at room temperature. The silicon- vacancy (SiV -) center in diamond has emerged as a possible candidate for a single photon source with all these characteristics. Unfortunately, due to the high refraction index mismatch between diamond and air, color centers in diamond show low photon out-coupling. This drawback can be overcome by fabrication of photonic structures that improve the in-coupling of excitation laser to the diamond defect as well as the out-couplingmore » emission from the color centers. An additional shortcoming is due to the random localization of native defects in the diamond sample. Here we demonstrate deterministic implantation of Si ions with high conversion effciency to single SiV -, targeted to fabricated nanowires. The co-localization of single SiV - defects with the nanostructures yields a ten times higher light coupling effciency as compared to single SiV - in the bulk. This result, with its intrinsic scalability, enables a new class of devices for integrated photonics and quantum information processing.« less
Root, Jenny R; Stevenson, Bradley S; Davis, Luann Ley; Geddes-Hall, Jennifer; Test, David W
2017-02-01
Computer-assisted instruction (CAI) is growing in popularity and has demonstrated positive effects for students with disabilities, including those with autism spectrum disorder (ASD). In this review, criteria for group experimental and single case studies were used to determine quality (Horner et al., Exceptional Children 71:165-179, 2005; Gersten et al., Exceptional Children 71:149-164, 2005; National Technical Assistance Center on Transition Center 2015). Included studies of high and adequate quality were further analyzed in terms of content, context, and specific instructional practices. Based on the NTACT criteria, this systematic review has established CAI as an evidence-based practice for teaching academics to students with ASD with support from 10 single-case and two group design studies of high or adequate quality. Suggestions for future research and implications for practice are discussed.
Coupling a single nitrogen-vacancy center with a superconducting qubit via the electro-optic effect
NASA Astrophysics Data System (ADS)
Li, Chang-Hao; Li, Peng-Bo
2018-05-01
We propose an efficient scheme for transferring quantum states and generating entangled states between two qubits of different nature. The hybrid system consists of a single nitrogen-vacancy (NV) center and a superconducting (SC) qubit, which couple to an optical cavity and a microwave resonator, respectively. Meanwhile, the optical cavity and the microwave resonator are coupled via the electro-optic effect. By adjusting the relative parameters, we can achieve high-fidelity quantum state transfer as well as highly entangled states between the NV center and the SC qubit. This protocol is within the reach of currently available techniques, and may provide interesting applications in quantum communication and computation with single NV centers and SC qubits.
Motivation to volunteer among senior center participants.
Pardasani, Manoj
2018-04-01
Senior centers in the United States play a vital role in the aging continuum of care as the focal points of a community-based system of services targeting independent older adults to promote their social integration and civically engagement. Although several studies have evaluated the diversity of senior center programs, demographic characteristics of participants, and benefits of participation, very few have explored motivations to volunteer among participants. Many senior centers rely on a cadre of participants who volunteer there to assist with programs and meal services. However, a systematic examination of volunteering interests and the rationale for volunteering among senior center participants has been missing from the literature. This mixed-methods study, conducted at a large suburban senior center, explores the interests and motivations of volunteerism among the participants. The study found that there was limited interest in volunteering among senior center participants. Those who were motivated to volunteer wanted to do so in order to stay connected with their community. There was strong interest in volunteering for single events or projects rather than a long-term commitment. Implications for senior centers are discussed.
Radiation damage induced in Al2O3 single crystal by 90 MeV Xe ions
NASA Astrophysics Data System (ADS)
Zirour, H.; Izerrouken, M.; Sari, A.
2015-12-01
Radiation damage induced in Al2O3 single crystal by 90 MeV Xe ions were investigated by optical absorption measurements, Raman spectroscopy and X-ray diffraction (XRD) techniques. The irradiations were performed at the GANIL accelerator in Caen, France for the fluence in the range from 1012 to 6 × 1013 cm-2 at room temperature under normal incidence. The F+ and F22+ centers kinetic as a function of fluence deduced from the optical measurements explains that the single defects (F and F+) aggregate to F center clusters (F2 , F2+, F22+) during irradiation at high fluence (>1013 cm-2). Raman and XRD analysis reveal a partial disorder of 40% of Al2O3 in the studied fluence range in accordance with Kabir et al. (2008) study. The result suggests that this is due to the stress relaxation process which occurs at high fluence (>1013 cm-2).
Planning Paths Through Singularities in the Center of Mass Space
NASA Technical Reports Server (NTRS)
Doggett, William R.; Messner, William C.; Juang, Jer-Nan
1998-01-01
The center of mass space is a convenient space for planning motions that minimize reaction forces at the robot's base or optimize the stability of a mechanism. A unique problem associated with path planning in the center of mass space is the potential existence of multiple center of mass images for a single Cartesian obstacle, since a single center of mass location can correspond to multiple robot joint configurations. The existence of multiple images results in a need to either maintain multiple center of mass obstacle maps or to update obstacle locations when the robot passes through a singularity, such as when it moves from an elbow-up to an elbow-down configuration. To illustrate the concepts presented in this paper, a path is planned for an example task requiring motion through multiple center of mass space maps. The object of the path planning algorithm is to locate the bang- bang acceleration profile that minimizes the robot's base reactions in the presence of a single Cartesian obstacle. To simplify the presentation, only non-redundant robots are considered and joint non-linearities are neglected.
NASA Astrophysics Data System (ADS)
Kim, Kiho; Yun, Jiwon; Lee, Donghyuck; Kim, Dohun
2018-02-01
A simple and convenient design enables real-time three-dimensional position tracking of nitrogen-vacancy (NV) centers in diamond. The system consists entirely of commercially available components (a single-photon counter, a high-speed digital-to-analog converter, a phase-sensitive detector-based feedback device, and a piezo stage), eliminating the need for custom programming or rigorous optimization processes. With a large input range of counters and trackers combined with high sensitivity of single-photon counting, high-speed position tracking (upper bound recovery time of 0.9 s upon 250 nm of step-like positional shift) not only of bright ensembles, but also of low-photon-collection-efficiency single to few NV centers (down to 103 s-1) is possible. The tracking requires position modulation of only 10 nm, which allows simultaneous position tracking and pulsed measurements in the long term. Therefore, this tracking system enables measuring a single-spin magnetic resonance and Rabi oscillations at a very high resolution even without photon collection optimization. The system is widely applicable to various fields related to NV center quantum manipulation research such as NV optical trapping, NV tracking in fluid dynamics, and biological sensing using NV centers inside a biological cell.
Crucibleless crystal growth and Radioluminescence study of calcium tungstate single crystal fiber
NASA Astrophysics Data System (ADS)
Silva, M. S.; Jesus, L. M.; Barbosa, L. B.; Ardila, D. R.; Andreeta, J. P.; Silva, R. S.
2014-11-01
In this article, single phase and high optical quality scheelite calcium tungstate single crystal fibers were grown by using the crucibleless laser heated pedestal growth technique. The as-synthesized calcium tungstate powders used for shaping seed and feed rods were investigated by X-ray diffraction technique. As-grown crystals were studied by Raman spectroscopy and Radioluminescence measurements. The results indicate that in both two cases, calcined powder and single crystal fiber, only the expected scheelite CaWO4 phase was observed. It was verified large homogeneity in the crystal composition, without the presence of secondary phases. The Radioluminescence spectra of the as-grown single crystal fibers are in agreement with that present in Literature for bulk single crystals, presented a single emission band centered at 420 nm when irradiated with β-rays.
A full-potential approach to the relativistic single-site Green's function
Liu, Xianglin; Wang, Yang; Eisenbach, Markus; ...
2016-07-07
One major purpose of studying the single-site scattering problem is to obtain the scattering matrices and differential equation solutions indispensable to multiple scattering theory (MST) calculations. On the other hand, the single-site scattering itself is also appealing because it reveals the physical environment experienced by electrons around the scattering center. In this study, we demonstrate a new formalism to calculate the relativistic full-potential single-site Green's function. We implement this method to calculate the single-site density of states and electron charge densities. Lastly, the code is rigorously tested and with the help of Krein's theorem, the relativistic effects and full potentialmore » effects in group V elements and noble metals are thoroughly investigated.« less
Fiadjoe, John E; Hirschfeld, Matthew; Wu, Stephan; Markley, James; Gurnaney, Harshad; Jawad, Abbas F; Stricker, Paul; Kilbaugh, Todd; Ross, Patrick; Kovatsis, Pete
2015-08-01
The GlideScope Cobalt Video laryngoscope is being used more often in children with challenging laryngoscopy. There are, however, no pediatric trials comparing it to flexible fiberoptic bronchoscopy, the current accepted gold standard. This preliminary manikin study compares the first-attempt intubation success of the GlideScope Cobalt video laryngoscope to the flexible fiberoptic bronchoscope when performed by attending pediatric anesthesiologists at two major pediatric centers. This prospective randomized, crossover study evaluated 120 attempts (60 with each study device) to intubate the AirSim Pierre Robin manikin (PRM) with fiberoptic bronchoscopy and video laryngoscopy (VL). Attending pediatric anesthesiologists from two quaternary pediatric centers were eligible to participate. Each attending anesthesiologist randomly performed a single tracheal intubation attempt with one of the study devices followed by the alternate method. The primary outcome was the first-attempt success rate of tracheal intubation. Blinding was not feasible. We hypothesized that first-attempt success would be higher with fiberoptic bronchoscopy. Thirty anesthesiologists from each center were randomized to use one of the study devices followed by the alternate method. We analyzed all participants' data. There was no overall difference in first-attempt success between VL and fiberoptic bronchoscopy (88.3% vs 85% respectively, P = 0.59). There were significant institutional differences in first-attempt success using VL (76.7% vs 100%). There was no difference in first-attempt success of tracheal intubation using VL vs fiberoptic bronchoscopy when performed by attending anesthesiologists at two large pediatric centers. However, institutional differences exist in success rates with VL across the two centers. Results from single-center device evaluations should be verified by multi-center evaluations. A significant proportion of attending anesthesiologists lack experience with advanced airway devices; targeted education may enhance intubation success and patient safety. © 2015 John Wiley & Sons Ltd.
De Serres, Sacha A; Caumartin, Yves; Noël, Réal; Lachance, Jean-Guy; Côté, Isabelle; Naud, Alain; Fradet, Yves; Mfarrej, Bechara G; Agharazii, Mohsen; Houde, Isabelle
2010-11-27
Organ shortage has led to the use of dual-kidney transplant (DKT) of very marginal donors into a single recipient to increase the use of marginal organs. To date, few data are available about the long-term outcome of DKT and its usefulness to increase the pool of available organ. We conducted a single-center cohort study of DKTs with longitudinal follow-up over an 8-year period. Between 1999 and 2007, 63 DKTs were performed. All kidneys from donors younger than 75 years refused by all centers for single transplantation, and kidneys from donors aged 75 years or older were routinely evaluated based on preimplantation glomerulosclerosis. Renal function, patient or graft survival, and perioperative complications were compared with 66 single kidneys from expanded criteria donors (ECD) and 63 ideal kidney donors. After a median follow-up of 56 months, patient or graft survival was similar between the three groups. Twelve-, 36-, and 84-month creatinine clearance were similar for DKT and ECD (12 months: 58 and 59 mL/min; 36 months: 54 and 60 mL/min; and 84 months: 62 and 51 mL/min, respectively). For the study period, the routine evaluation of very marginal kidneys for DKT in our center has led to an increase of 47% in the transplants from donors aged 50 years or older, which represent 12% at the level of our organ procurement organization. DKT patients can expect long-term results comparable with single kidney ECD. The implementation of a DKT program in our unit safely increased the pool of organs from marginal donors.
Enhanced water purification: a single atom makes a difference.
Stewart, Tom A; Trudell, Daniel E; Alam, Todd M; Ohlin, C André; Lawler, Christian; Casey, William H; Jett, Stephen; Nyman, May
2009-07-15
The aluminum Keggin polycation (Al13) has been identified as an effective specie for neutralization and coagulation of anionic contaminants in water. In this study, we compare efficacy of the aluminum Keggin-ion to the analogues containing a single Ga-atom or single Ge-atom (GaAl12 and GeAl12, respectively) substituted into the center of the polycation in water-treatment studies. We investigated removal of bacteriophage (model viruses), Cryptosporidium, dissolved organic carbon (DOC), and turbidity. In every study, the order of contaminant removal efficacy trends GaAl12 > Al13 > GeAl12. By ESI MS (electrospray ionization mass spectrometry), we noted the GaAl12 deprotonates least of the three aluminum polycations, and thus probably carries the highest charge, and also optimal contaminant-neutralization ability. The ESI MS studies of the aluminum polycation solutions, as well as solid-state characterization of their resulting precipitates both reveal some conversion of Al13 to larger polycations, Al30 for instance. The GaAl12 does not show any evidence for this alteration that is responsible for poor shelf life of commercial prehydrolyzed aluminum coagulants such as polyaluminum chloride. Based on these studies, we conclude that substitution of a single Ga-atom in the center of the aluminum Keggin polycation produces an optimal water-treatment product due to enhanced shelf life and efficacy in neutralization of anionic contaminants.
Di Nardo, Giovanni; Rossi, Paolo; Oliva, Salvatore; Aloi, Marina; Cozzi, Denis A; Frediani, Simone; Redler, Adriano; Mallardo, Saverio; Ferrari, Federica; Cucchiara, Salvatore
2012-11-01
The use of pneumatic dilation (PD) is well established in adults with achalasia; however, it is less commonly used in children. To evaluate the efficacy of PD in pediatric achalasia and to define predictive factors for its treatment failure. Single-center, prospective cohort study. Academic tertiary referral center. Twenty-four patients with achalasia were enrolled from January 2004 to November 2009 and were followed for a median of 6 years. PD was performed with the patients under general anesthesia. Efficacy and safety of PD. Follow-up was performed by using the Eckardt score, barium swallow contrast studies, and esophageal manometry at baseline; 1, 3, and 6 months after dilation; and every year thereafter. A Cox regression model was used to identify independent predictors of failure after the first PD. The PD success rate was 67%. In 8 patients, the first PD failed, but the parents of one patient refused a second PD and requested surgery. Of the 7 patients who underwent repeated treatment, the second PD failed in 3 (43%). Overall, only 3 of the 24 patients underwent surgery (overall success rate after a maximum of 3 PDs was 87%). Multivariate analysis showed that only older age was independently associated with a higher probability of the procedure success (hazard ratio [HR] 0.66; 95% CI, 0.45-0.97). Small sample size, single-center study. PD is a safe and effective technique in the management of pediatric achalasia. Young age is an independent negative predictive factor for successful clinical outcome. Copyright © 2012 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.
Choi, Kyunghak; Han, Youngjin; Ko, Gi-Young; Cho, Yong-Pil; Kwon, Tae-Won
2018-06-09
The objective of the study was to compare the treatment outcomes and cost of endovascular aortic aneurysm repair (EVAR) and open surgical repair (OSR) in patients with an abdominal aortic aneurysm (AAA) at a single center. Patients treated for an AAA at a single center between January 2007 and December 2012 were retrospectively identified and classified based on the treatment they received (EVAR or OSR). Patient demographics and in-hospital costs were recorded. Long-term survival was calculated using the Kaplan-Meier method. During the study period, 401 patients with AAA were treated at Asan Medical Center. Among these cases, 226 were treated with EVAR (56%) and 175 received OSR (44%). The mean age of the EVAR group was higher than that of the OSR group (71.25 ± 7.026 vs. 61.26 ± 8.175, P < 0.001). The need for intraoperative transfusion and total length of in-hospital stay were significantly lower in the EVAR group (P < 0.001). The OSR group showed significantly reduced rates of overall mortality (P = 0.003), overall reintervention (P = 0.001), and long-term survival (63.98 ± 1.86 vs. 99.54 ± 3.17, P < 0.001). The OSR group was charged significantly less than the EVAR group ($12,879.21 USD vs. $18,057.78 USD, P < 0.001). EVAR has advantages over OSR in terms of short-term mortality, in-hospital length of stay, and rates of perioperative transfusion. However, OSR is associated with better long-term survival, lower reintervention rates, and lower costs. Copyright © 2018 Elsevier Inc. All rights reserved.
ERIC Educational Resources Information Center
Brown, Stephen; Birch, David; Thyagaraj, Sujan; Teufel, James; Phillips, Cheryl
2007-01-01
One in five students report experimenting with tobacco before the age of 13 and most prevention efforts take place in the school setting. This study measures the effect of a single-lesson tobacco prevention curriculum, conducted by a health education center, focusing on knowledge of tobacco, ability to identify refusal techniques, and intent not…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Xianglin; Wang, Yang; Eisenbach, Markus
One major purpose of studying the single-site scattering problem is to obtain the scattering matrices and differential equation solutions indispensable to multiple scattering theory (MST) calculations. On the other hand, the single-site scattering itself is also appealing because it reveals the physical environment experienced by electrons around the scattering center. In this study, we demonstrate a new formalism to calculate the relativistic full-potential single-site Green's function. We implement this method to calculate the single-site density of states and electron charge densities. Lastly, the code is rigorously tested and with the help of Krein's theorem, the relativistic effects and full potentialmore » effects in group V elements and noble metals are thoroughly investigated.« less
Competition of the self-activated and Mn-related luminescence in ZnS single crystals
NASA Astrophysics Data System (ADS)
Bacherikov, Yu. Yu.; Vorona, I. P.; Markevich, I. V.; Korsunska, N. O.; Kurichka, R. V.
2018-06-01
The photoluminescence (PL) and photoluminescence excitation (PLE) spectra of ZnS single crystals thermally doped from ZnS/MnS mixture were studied at 300 and 77 K. PL spectra exhibit bands caused by Mn-related centers and centers of self-activated (SA) emission. Besides intrinsic maximum, a number of narrow peaks corresponded to Mn-related absorption are found in the PLE spectra of both SA and Mn-related emission. A redistribution of SA and Mn-related emission intensities is observed with temperature change. The mechanism of this phenomenon involving free hole trapping by MnZn and the possible position of a ground energy level of substitutional Mn are discussed.
Direct experimental observation of nonclassicality in ensembles of single-photon emitters
NASA Astrophysics Data System (ADS)
Moreva, E.; Traina, P.; Forneris, J.; Degiovanni, I. P.; Ditalia Tchernij, S.; Picollo, F.; Brida, G.; Olivero, P.; Genovese, M.
2017-11-01
In this work we experimentally demonstrate a recently proposed criterion addressed to detect nonclassical behavior in the fluorescence emission of ensembles of single-photon emitters. In particular, we apply the method to study clusters of nitrogen-vacancy centers in diamond characterized with single-photon-sensitive confocal microscopy. Theoretical considerations on the behavior of the parameter at any arbitrary order in the presence of Poissonian noise are presented and, finally, the opportunity of detecting manifold coincidences is discussed.
Cote, Claudia; MacLeod, Jeffrey B; Yip, Alexandra M; Ouzounian, Maral; Brown, Craig D; Forgie, Rand; Pelletier, Marc P; Hassan, Ansar
2015-01-01
Rates of perioperative transfusion vary widely among patients undergoing cardiac surgery. Few studies have examined factors beyond the clinical characteristics of the patients that may be responsible for such variation. The purpose of this study was to determine whether differing practice patterns had an impact on variation in perioperative transfusion at a single center. Patients who underwent cardiac surgery at a single center between 2004 and 2011 were considered. Comparisons were made between patients who had received a perioperative transfusion and those who had not from the clinical factors at baseline, intraoperative variables, and differing practice patterns, as defined by the surgeon, anesthesiologist, perfusionist, and the year in which the procedure was performed. The risk-adjusted effect of these factors on perioperative transfusion rates was determined using multivariable regression modeling techniques. The study population comprised 4823 patients, of whom 1929 (40.0%) received a perioperative transfusion. Significant variation in perioperative transfusion rates was noted between surgeons (from 32.4% to 51.5%, P < .0001), anesthesiologists (from 34.4% to 51.9%, P < .0001) and across year (from 28.2% in 2004 to 48.8% in 2008, P < .0001). After adjustment for baseline and intraoperative variables, surgeon, anesthesiologist, and year of procedure were each found to be independent predictors of perioperative transfusion. Differing practice patterns contribute to significant variation in rates of perioperative transfusion within a single center. Strategies aimed at reducing overall transfusion rates must take into account such variability in practice patterns and account for nonclinical factors as well as known clinical predictors of blood transfusions. Copyright © 2015 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.
Transmission of low-energy negative ions through insulating nanocapillaries
NASA Astrophysics Data System (ADS)
Zhang, Qi; Liu, Zhonglin; Li, Pengfei; Jin, Bo; Song, Guangyin; Jin, Dingkun; Niu, Ben; Wei, Long; Ha, Shuai; Xie, Yiming; Ma, Yue; Wan, Chengliang; Cui, Ying; Zhou, Peng; Zhang, Hongqiang; Chen, Ximeng
2018-04-01
A simulation is performed to study the transmission of low-energy C l- ions through A l2O3 nanocapillaries. For the trajectory simulations, there are several processes involved: the image forces induced by the projectile; the electrostatic force from the deposited charges; the scattering from the inner surface and charge exchange. The simulation reproduces the main features of the experiments; i.e., the double peak structure in the transmitted angular distribution and the transmitted fractions of C l- , C l+ , and C l0 were found in the charge state distribution. The transmitted C l- ions are centered around the beam direction while the transmitted fractions of C l0 and C l+ are centered around the tilt angles. The role of the deposited charge is also studied by simulations. With the deposited charge, it is found that C l- is dominant in the transmission and the majority of the ions, centered around the tilt angle, are mainly from the single deflection by the negative charge patches on the inner surfaces of the capillaries, and only a few directly transmitted C l- ions are centered around the incident direction. There are also a few transmitted fractions of C l0 and C l+ from close surface scatterings. In the case that there are no negative charge patches, the simulation agrees with the experiment in detail: The majority of the directly transmitted C l- ions are centered around the incident direction while only a few scattered C l- ions are centered around the tilt angle from the single close collisions with the inner surfaces of the capillaries. There is a portion, comparable to the transmitted fraction of C l- , of the transmitted fractions of C l0 and C l+ , centered around the tilt angle, from the single scatterings with the inner surfaces of the capillaries. This confirms that at the present experimental conditions there are most probably no negative charge patches formed to guide the negative ions through insulating A l2O3 nanocapillaries.
Measuring mechanical motion with a single spin
NASA Astrophysics Data System (ADS)
Bennett, S. D.; Kolkowitz, S.; Unterreithmeier, Q. P.; Rabl, P.; Bleszynski Jayich, A. C.; Harris, J. G. E.; Lukin, M. D.
2012-12-01
We study theoretically the measurement of a mechanical oscillator using a single two-level system as a detector. In a recent experiment, we used a single electronic spin associated with a nitrogen-vacancy center in diamond to probe the thermal motion of a magnetized cantilever at room temperature (Kolkowitz et al 2012 Science 335 1603). Here, we present a detailed analysis of the sensitivity limits of this technique, as well as the possibility to measure the zero-point motion of the oscillator. Further, we discuss the issue of measurement backaction in sequential measurements and find that although backaction heating can occur, it does not prohibit the detection of zero-point motion. Throughout the paper, we focus on the experimental implementation of a nitrogen-vacancy center coupled to a magnetic cantilever; however, our results are applicable to a wide class of spin-oscillator systems. The implications for the preparation of nonclassical states of a mechanical oscillator are also discussed.
Orbital State Manipulation of a Diamond Nitrogen-Vacancy Center Using a Mechanical Resonator
NASA Astrophysics Data System (ADS)
Chen, H. Y.; MacQuarrie, E. R.; Fuchs, G. D.
2018-04-01
We study the resonant optical transitions of a single nitrogen-vacancy (NV) center that is coherently dressed by a strong mechanical drive. Using a gigahertz-frequency diamond mechanical resonator that is strain coupled to a NV center's orbital states, we demonstrate coherent Raman sidebands out to the ninth order and orbital-phonon interactions that mix the two excited-state orbital branches. These interactions are spectroscopically revealed through a multiphonon Rabi splitting of the orbital branches which scales as a function of resonator driving amplitude and is successfully reproduced in a quantum model. Finally, we discuss the application of mechanical driving to engineering NV-center orbital states.
An analytical and experimental study of crack extension in center-notched composites
NASA Technical Reports Server (NTRS)
Beuth, Jack L., Jr.; Herakovich, Carl T.
1987-01-01
The normal stress ratio theory for crack extension in anisotropic materials is studied analytically and experimentally. The theory is applied within a microscopic-level analysis of a single center notch of arbitrary orientation in a unidirectional composite material. The bulk of the analytical work of this study applies an elasticity solution for an infinite plate with a center line to obtain critical stress and crack growth direction predictions. An elasticity solution for an infinite plate with a center elliptical flaw is also used to obtain qualitative predictions of the location of crack initiation on the border of a rounded notch tip. The analytical portion of the study includes the formulation of a new crack growth theory that includes local shear stress. Normal stress ratio theory predictions are obtained for notched unidirectional tensile coupons and unidirectional Iosipescu shear specimens. These predictions are subsequently compared to experimental results.
1987-01-01
BLOOD FLOW CHANGE Steven E. Petersen, Peter T. Fox, Michael I. Posner, Marcus Raichle McDonnell Center for Studies of Higher Brain Function...Single Words Using Positron Emission Tomographic Measurements of Cerebral Blood Flow Change *= ’I PERSONAL AUTHOR(S) * Petersen, Steven E. 13a. TYPE OF...CHANGE Steven E. Petersen, Peter T. Fox, Michael I. Posner, Marcus E. Raichle INTRODUCTION Language is an essential characteristic of the human
Optical characterization of single-crystal diamond grown by DC arc plasma jet CVD
NASA Astrophysics Data System (ADS)
Hei, Li-fu; Zhao, Yun; Wei, Jun-jun; Liu, Jin-long; Li, Cheng-ming; Lü, Fan-xiu
2017-12-01
Optical centers of single-crystal diamond grown by DC arc plasma jet chemical vapor deposition (CVD) were examined using a low-temperature photoluminescence (PL) technique. The results show that most of the nitrogen-vacancy (NV) complexes are present as NV- centers, although some H2 and H3 centers and B-aggregates are also present in the single-crystal diamond because of nitrogen aggregation resulting from high N2 incorporation and the high mobility of vacancies under growth temperatures of 950-1000°C. Furthermore, emissions of radiation-induced defects were also detected at 389, 467.5, 550, and 588.6 nm in the PL spectra. The reason for the formation of these radiation-induced defects is not clear. Although a Ni-based alloy was used during the diamond growth, Ni-related emissions were not detected in the PL spectra. In addition, the silicon-vacancy (Si-V)-related emission line at 737 nm, which has been observed in the spectra of many previously reported microwave plasma chemical vapor deposition (MPCVD) synthetic diamonds, was absent in the PL spectra of the single-crystal diamond prepared in this work. The high density of NV- centers, along with the absence of Ni-related defects and Si-V centers, makes the single-crystal diamond grown by DC arc plasma jet CVD a promising material for applications in quantum computing.
Success of single-balloon enteroscopy in patients with surgically altered anatomy.
Kurzynske, Frank C; Romagnuolo, Joseph; Brock, Andrew S
2015-08-01
Single-balloon enteroscopy (SBE) was introduced in 2007 to diagnose and treat small-bowel disorders. No study to date has evaluated SBE in patients with surgically altered anatomy outside of ERCP. To evaluate the efficacy, yield, and safety of SBE in patients with surgically altered anatomy. Retrospective study. Tertiary-care academic medical center. All patients with altered surgical anatomy who underwent SBE at the Medical University of South Carolina from July 2007 to September 2013. SBE. Diagnostic yield, therapeutic yield, technical success, and adverse events. A total of 48 patients met inclusion criteria. Mean age was 56 years (77% female). Eleven patients underwent single-balloon PEG placement, 8 single-balloon ERCP, 22 non-PEG/non-ERCP anterograde SBE, and 7 retrograde SBE. Previous surgeries included Roux-en-Y gastric bypass (n=26), small-intestine resection (n=6), colon resection (n=5), Whipple procedure (n=4), choledochojejunostomy (n=3), hepaticojejunostomy (n=1), Billroth I (n=1), Billroth II (n=1), and Puestow procedure (n=1). Procedural indications were PEG tube placement (n=11), choledocholithiasis (n=2), biliary stricture (n=2), obstructive jaundice (n=1), cholangitis (n=1), ampullary mass (n=1), sphincter of Oddi dysfunction (n=1), anemia and/or bleeding (n=15), abdominal pain (n=9), radiologic evidence of obstruction (n=3), and Peutz-Jeghers syndrome (n=2). The technical success rate was 73% in single-balloon PEG placement, 88% in single-balloon ERCP, 82% in other anterograde SBEs, and 86% in retrograde SBEs. No intraprocedural or postprocedural adverse events were observed. Single center, retrospective study. SBE is safe and effective in patients with surgically altered anatomy. Copyright © 2015 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.
Myer, Gregory D; Wordeman, Samuel C; Sugimoto, Dai; Bates, Nathaniel A; Roewer, Benjamin D; Medina McKeon, Jennifer M; DiCesare, Christopher A; Di Stasi, Stephanie L; Barber Foss, Kim D; Thomas, Staci M; Hewett, Timothy E
2014-05-01
Multi-center collaborations provide a powerful alternative to overcome the inherent limitations to single-center investigations. Specifically, multi-center projects can support large-scale prospective, longitudinal studies that investigate relatively uncommon outcomes, such as anterior cruciate ligament injury. This project was conceived to assess within- and between-center reliability of an affordable, clinical nomogram utilizing two-dimensional video methods to screen for risk of knee injury. The authors hypothesized that the two-dimensional screening methods would provide good-to-excellent reliability within and between institutions for assessment of frontal and sagittal plane biomechanics. Nineteen female, high school athletes participated. Two-dimensional video kinematics of the lower extremity during a drop vertical jump task were collected on all 19 study participants at each of the three facilities. Within-center and between-center reliability were assessed with intra- and inter-class correlation coefficients. Within-center reliability of the clinical nomogram variables was consistently excellent, but between-center reliability was fair-to-good. Within-center intra-class correlation coefficient for all nomogram variables combined was 0.98, while combined between-center inter-class correlation coefficient was 0.63. Injury risk screening protocols were reliable within and repeatable between centers. These results demonstrate the feasibility of multi-site biomechanical studies and establish a framework for further dissemination of injury risk screening algorithms. Specifically, multi-center studies may allow for further validation and optimization of two-dimensional video screening tools. 2b.
Shin, Hyun Phil; Burman, Blaire; Kozarek, Richard A.; Zeigler, Amy; Wang, Chia; Lee, Houghton; Zehr, Troy; Edwards, Alicia M.; Siddique, Asma
2017-01-01
Background/Aims The approval of sofosbuvir (SOF), a direct-acting antiviral, has revolutionized the treatment of chronic hepatitis C virus (HCV). Methods We assessed the sustained virological response (SVR) of SOF-based regimens in a real-world single-center setting for the treatment of chronic HCV genotype 1 (G1) patients. This was a retrospective review of chronic HCV G1 adult patients treated with a SOF-based regimen at Virginia Mason Medical Center between December 2013 and August 2015. Results The cohort comprised 343 patients. Patients received SOF+ledipasvir (LDV) (n=155), SOF+simeprevir (SIM) (n=154), or SOF+peginterferon (PEG)+ribavirin (RBV) (n=34). Of the patients, 50.1% (n=172) had cirrhosis. The SVR rate was 92.2% for SOF/LDV, 87.0% for SOF/SIM, and 82.4% for SOF/PEG/RBV. Compared with the cirrhotic patients, the patients without cirrhosis had a higher SVR (96.8% vs 85.5%, p=0.01, SOF/LDV; 98.2% vs 80.6%, p=0.002, SOF/SIM; 86.4% vs 75.0%, p=0.41, SOF/PEG/RBV). In this study, prior treatment experience adversely affected the response rate in subjects treated with SOF/PEG/RBV. Conclusions In this single-center, real-world setting, the treatment of chronic HCV G1 resulted in a high rate of SVR, especially in patients without cirrhosis. PMID:28651301
Shin, Hyun Phil; Burman, Blaire; Kozarek, Richard A; Zeigler, Amy; Wang, Chia; Lee, Houghton; Zehr, Troy; Edwards, Alicia M; Siddique, Asma
2017-09-15
The approval of sofosbuvir (SOF), a direct-acting antiviral, has revolutionized the treatment of chronic hepatitis C virus (HCV). We assessed the sustained virological response (SVR) of SOF-based regimens in a real-world single-center setting for the treatment of chronic HCV genotype 1 (G1) patients. This was a retrospective review of chronic HCV G1 adult patients treated with a SOF-based regimen at Virginia Mason Medical Center between December 2013 and August 2015. The cohort comprised 343 patients. Patients received SOF+ledipasvir (LDV) (n=155), SOF+simeprevir (SIM) (n=154), or SOF+peginterferon (PEG)+ribavirin (RBV) (n=34). Of the patients, 50.1% (n=172) had cirrhosis. The SVR rate was 92.2% for SOF/LDV, 87.0% for SOF/SIM, and 82.4% for SOF/PEG/RBV. Compared with the cirrhotic patients, the patients without cirrhosis had a higher SVR (96.8% vs 85.5%, p=0.01, SOF/LDV; 98.2% vs 80.6%, p=0.002, SOF/SIM; 86.4% vs 75.0%, p=0.41, SOF/PEG/RBV). In this study, prior treatment experience adversely affected the response rate in subjects treated with SOF/PEG/RBV. In this single-center, real-world setting, the treatment of chronic HCV G1 resulted in a high rate of SVR, especially in patients without cirrhosis.
Zhang, Jingyuan Linda; Lagoudakis, Konstantinos G.; Tzeng, Yan -Kai; ...
2017-10-23
Arrays of identical and individually addressable qubits lay the foundation for the creation of scalable quantum hardware such as quantum processors and repeaters. Silicon-vacancy (SiV) centers in diamond offer excellent physical properties such as low inhomogeneous broadening, fast photon emission, and a large Debye–Waller factor. The possibility for all-optical ultrafast manipulation and techniques to extend the spin coherence times makes them promising candidates for qubits. Here, we have developed arrays of nanopillars containing single (SiV) centers with high yield, and we demonstrate ultrafast all-optical complete coherent control of the excited state population of a single SiV center at the opticalmore » transition frequency. The high quality of the chemical vapor deposition (CVD) grown SiV centers provides excellent spectral stability, which allows us to coherently manipulate and quasi-resonantly read out the excited state population of individual SiV centers on picosecond timescales using ultrafast optical pulses. Furthermore, this work opens new opportunities to create a scalable on-chip diamond platform for quantum information processing and scalable nanophotonics applications.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Jingyuan Linda; Lagoudakis, Konstantinos G.; Tzeng, Yan -Kai
Arrays of identical and individually addressable qubits lay the foundation for the creation of scalable quantum hardware such as quantum processors and repeaters. Silicon-vacancy (SiV) centers in diamond offer excellent physical properties such as low inhomogeneous broadening, fast photon emission, and a large Debye–Waller factor. The possibility for all-optical ultrafast manipulation and techniques to extend the spin coherence times makes them promising candidates for qubits. Here, we have developed arrays of nanopillars containing single (SiV) centers with high yield, and we demonstrate ultrafast all-optical complete coherent control of the excited state population of a single SiV center at the opticalmore » transition frequency. The high quality of the chemical vapor deposition (CVD) grown SiV centers provides excellent spectral stability, which allows us to coherently manipulate and quasi-resonantly read out the excited state population of individual SiV centers on picosecond timescales using ultrafast optical pulses. Furthermore, this work opens new opportunities to create a scalable on-chip diamond platform for quantum information processing and scalable nanophotonics applications.« less
DiCesare, Christopher A.; Bates, Nathaniel A.; Barber Foss, Kim D.; Thomas, Staci M.; Wordeman, Samuel C.; Sugimoto, Dai; Roewer, Benjamin D.; Medina McKeon, Jennifer M.; Di Stasi, Stephanie; Noehren, Brian W.; Ford, Kevin R.; Kiefer, Adam W.; Hewett, Timothy E.; Myer, Gregory D.
2015-01-01
Background: Anterior cruciate ligament (ACL) injuries are physically and financially devastating but affect a relatively small percentage of the population. Prospective identification of risk factors for ACL injury necessitates a large sample size; therefore, study of this injury would benefit from a multicenter approach. Purpose: To determine the reliability of kinematic and kinetic measures of a single-leg cross drop task across 3 institutions. Study Design: Controlled laboratory study. Methods: Twenty-five female high school volleyball players participated in this study. Three-dimensional motion data of each participant performing the single-leg cross drop were collected at 3 institutions over a period of 4 weeks. Coefficients of multiple correlation were calculated to assess the reliability of kinematic and kinetic measures during the landing phase of the movement. Results: Between-centers reliability for kinematic waveforms in the frontal and sagittal planes was good, but moderate in the transverse plane. Between-centers reliability for kinetic waveforms was good in the sagittal, frontal, and transverse planes. Conclusion: Based on these findings, the single-leg cross drop task has moderate to good reliability of kinematic and kinetic measures across institutions after implementation of a standardized testing protocol. Clinical Relevance: Multicenter collaborations can increase study numbers and generalize results, which is beneficial for studies of relatively rare phenomena, such as ACL injury. An important step is to determine the reliability of risk assessments across institutions before a multicenter collaboration can be initiated. PMID:26779550
ADHD Symptom Reduction in Elementary Students: A Single-Case Effectiveness Design
ERIC Educational Resources Information Center
Schottelkorb, April A.; Ray, Dee C.
2009-01-01
The authors used a single-case design to examine the effectiveness of child-centered play therapy (CCPT) and person-centered teacher consultation (PCTC) for four elementary students identified with attention deficit hyperactivity disorder (ADHD) symptoms. Two students participated in CCPT and their teachers participated in PCTC. Two students…
Economic Burden of Road Traffic Accidents; Report from a Single Center from South Eastern Iran.
Sargazi, Aliyeh; Sargazi, Atefeh; Nadakkavukaran Jim, Prigil Kumar; Danesh, HoseinAli; Aval, ForoughSargolzaee; Kiani, Zohre; Lashkarinia, AmirHosein; Sepehri, Zahra
2016-01-01
To determine the economic burden of road traffic accidents (RTAs) in patients admitted to a single center in south eastern Iran. This cross-sectional study was conducted in Amir-Al-Momenin hospital of Zabol affiliated with Zabol University of Medical Sciences during a 12-month period from April 2012 to April 2013. All the RTAs patients who were admitted to our emergency department were included. The direct expenses of hospital care were recorded according to their medical charts and the accountant registration information. Data are presented according to different RTAs characteristics. Overall 1155 patients were included in the current study with mean age of 36.7 ± 5.14 years among whom there were 673(58.3%) men and 482 (41.7%) women. The annual incidence of RTAs were calculated to be 288 per 100,000 population. The RTAs economic burden in our center was 589,448.49 USD which accounted for 10.4% of total hospital expenses during the study period. The money spend on RTAs in our center was 130 times more than gross national income per capita. Cost of each patient in road traffic was 15 times more than cost of an average patient of the hospital in other sections. With considerable high ratio of accidents in Zabol, proper intervention is needed for controlling and preventing RTAs in order to decrease its injuries, impact and the associated economic burden.
A real-time digital computer program for the simulation of a single rotor helicopter
NASA Technical Reports Server (NTRS)
Houck, J. A.; Gibson, L. H.; Steinmetz, G. G.
1974-01-01
A computer program was developed for the study of a single-rotor helicopter on the Langley Research Center real-time digital simulation system. Descriptions of helicopter equations and data, program subroutines (including flow charts and listings), real-time simulation system routines, and program operation are included. Program usage is illustrated by standard check cases and a representative flight case.
Ito, Hiroaki; Inoue, Haruhiro; Odaka, Noriko; Satodate, Hitoshi; Suzuki, Michitaka; Mukai, Shumpei; Takehara, Yusuke; Omoto, Tomokatsu; Kudo, Shin-ei
2013-01-01
Background. This study addresses clinicopathological differences between patients with gastric cardia and subcardial cancer with and without esophagogastric junctional invasion. Methods. We performed a single-center, retrospective cohort study. We studied patients who underwent curative surgery for gastric cardia and subcardial cancers. Tumors centered in the proximal 5 cm of the stomach were classed into two types, according to whether they did (Ge) or did not (G) invade the esophagogastric junction. Results. A total of 80 patients were studied; 19 (73.1%) of 26 Ge tumors and 16 (29.6%) of 54 G tumors had lymph nodes metastases. Incidence of nodal metastasis in pT1 tumors was significantly higher in the Ge tumor group. No nodal metastasis in cervical lymph nodes was recognized. Only two patients with Ge tumors had mediastinal lymph node metastases. Incidence of perigastric lymph node metastasis was significantly higher in those with Ge tumors. Ge tumors tended to be staged as progressive disease using the esophageal cancer staging manual rather than the gastric cancer staging manual. Conclusion. Because there are some differences in clinicopathological characteristics, it is thought to be adequate to distinguish type Ge from type G tumor. PMID:23365732
Yunus, Mahira; Aziz, Tahir; Mubarak, Muhammed
2012-01-01
To study the incidence, types and distribution pattern of malignant tumors in renal transplant recipients at a single center in Pakistan. This retrospective study was conducted at Sindh Institute of Urology and Transplantation (SIUT) and included all transplant patients on regular follow-up from November 1986 to December 2008. The original biopsy reports and case files of all patients who developed posttransplant malignancies were reviewed and relevant demographic, clinical, radiological, and histopathological data were retrieved and analyzed. SPSS version 10.0 was used for statistical analysis. Over 22 years of study period, 1816 renal transplants were carried out at our center. Among these, 44 patients developed malignancies constituting an overall incidence rate of 2.4%. All patients in this study were males with a mean age of 34.9±9.5 years (range: 9 to 60 years). The most common type of malignancy was lymphoma (27 patients, 61.4%), followed by Kaposi's sarcoma (11 patients, 25%) and skin malignancies (3 patients, 6.8%). One case each of adenocarcinoma of the gallbladder, acute myeloid leukemia (AML), conjunctival carcinoma-in-situ and seminoma were also diagnosed. Posttransplant malignancies occurring in our renal transplant recipients show different incidence rates and patterns as compared with western studies.
ERIC Educational Resources Information Center
Cosbey, Joanna; Muldoon, Deirdre
2017-01-01
This study evaluated the effectiveness of a family-centered feeding intervention, Easing Anxiety Together with Understanding and Perseverance (EAT-UP™), for promoting food acceptance of children with autism spectrum disorder at home. A concurrent multiple-baseline design was used with systematic replication across three families. Baseline was…
Task Allocation for Single Pilot Operations: A Role for the Ground
NASA Technical Reports Server (NTRS)
Johnson, Walter; Lachter, Joel; Feary, Mike; Comerford, Doreen; Battiste, Vernol; Mogford, Richard
2012-01-01
Researchers at NASA Ames Research Center and NASA Langley Research Center are jointly investigating issues associated with potential configurations for an environment in which a single pilot, or reduced crew, might operate. The research summarized in this document represents several of the efforts being put forth at NASA Ames Research Center. Specifically, researchers at NASA Ames Research Center coordinated and hosted a technical interchange meeting in order to gain insight from members of the aviation community. A description of this meeting and the findings are presented first. Thereafter, plans for ensuing research are presented.
Kamperman, Tom; Henke, Sieger; Visser, Claas Willem; Karperien, Marcel; Leijten, Jeroen
2017-06-01
Single-cell-laden microgels support physiological 3D culture conditions while enabling straightforward handling and high-resolution readouts of individual cells. However, their widespread adoption for long-term cultures is limited by cell escape. In this work, it is demonstrated that cell escape is predisposed to off-center encapsulated cells. High-speed microscopy reveals that cells are positioned at the microgel precursor droplets' oil/water interface within milliseconds after droplet formation. In conventional microencapsulation strategies, the droplets are typically gelled immediately after emulsification, which traps cells in this off-center position. By delaying crosslinking, driving cells toward the centers of microgels is succeeded. The centering of cells in enzymatically crosslinked microgels prevents their escape during at least 28 d. It thereby uniquely enables the long-term culture of individual cells within <5-µm-thick 3D uniform hydrogel coatings. Single cell analysis of mesenchymal stem cells in enzymatically crosslinked microgels reveals unprecedented high cell viability (>90%), maintained metabolic activity (>70%), and multilineage differentiation capacity (>60%) over a period of 28 d. The facile nature of this microfluidic cell-centering method enables its straightforward integration into many microencapsulation strategies and significantly enhances control, reproducibility, and reliability of 3D single cell cultures. © 2017 The Authors. Published by WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Gorin, Michael A; Kates, Max; Mullins, Jeffrey K; Pierorazio, Phillip M; Matlaga, Brian R; Schoenberg, Mark P; Bivalacqua, Trinity J
2014-02-01
The objective of this study was to evaluate the impact of hospital case volume on perioperative outcomes and costs of radical cystectomy (RC) after controlling for differences in patient case mix. The Maryland Health Services Cost Review Commission database was queried for patients who underwent an open RC between 2000 and 2011. Patients were divided into tertiles based on hospital case volume. Groups were compared for differences in length of intensive care unit (ICU) stay, length of total hospital stay, rate of in-hospital deaths and procedure-related costs. In total, 1620 patients underwent a RC during the study period. Of these patients, 457 (28.2%) underwent surgery at 37 low volume centers, 465 (28.7%) at six mid volume centers and 698 (43.1%) at a single high volume center. The mean case volume of each group was 1.1, 7.0 and 63.5 RC/center/year, respectively. After controlling for marked differences in patient case mix, having surgery at the single high-volume center was independently associated with a decrease in length of ICU stay (coefficient = -0.41 days, 95% CI -0.78--0.05, p = 0.03), in-hospital mortality (OR 0.18, 95% CI 0.04-0.80, p = 0.02) and total medical costs (coefficient = -2.91k USD, 95% CI -4.15--1.67, p < 0.001). Decreased total costs were driven by reductions in charges associated with the operating room, drugs, radiology tests, labs, supplies and physical/occupational therapy (all p < 0.001). Undergoing RC at a high volume medical center was associated with improved outcomes and reduced costs. These data support the centralization of RC to high volume centers.
DiCesare, Christopher A; Bates, Nathaniel A; Barber Foss, Kim D; Thomas, Staci M; Wordeman, Samuel C; Sugimoto, Dai; Roewer, Benjamin D; Medina McKeon, Jennifer M; Di Stasi, Stephanie; Noehren, Brian W; Ford, Kevin R; Kiefer, Adam W; Hewett, Timothy E; Myer, Gregory D
2015-12-01
Anterior cruciate ligament (ACL) injuries are physically and financially devastating but affect a relatively small percentage of the population. Prospective identification of risk factors for ACL injury necessitates a large sample size; therefore, study of this injury would benefit from a multicenter approach. To determine the reliability of kinematic and kinetic measures of a single-leg cross drop task across 3 institutions. Controlled laboratory study. Twenty-five female high school volleyball players participated in this study. Three-dimensional motion data of each participant performing the single-leg cross drop were collected at 3 institutions over a period of 4 weeks. Coefficients of multiple correlation were calculated to assess the reliability of kinematic and kinetic measures during the landing phase of the movement. Between-centers reliability for kinematic waveforms in the frontal and sagittal planes was good, but moderate in the transverse plane. Between-centers reliability for kinetic waveforms was good in the sagittal, frontal, and transverse planes. Based on these findings, the single-leg cross drop task has moderate to good reliability of kinematic and kinetic measures across institutions after implementation of a standardized testing protocol. Multicenter collaborations can increase study numbers and generalize results, which is beneficial for studies of relatively rare phenomena, such as ACL injury. An important step is to determine the reliability of risk assessments across institutions before a multicenter collaboration can be initiated.
Texter, Karen; Davis, Jo Ann M; Phelps, Christina; Cheatham, Sharon; Cheatham, John; Galantowicz, Mark; Feltes, Timothy F
2017-07-01
With increasing survival of children with HLHS and other single ventricle lesions, the complexity of medical care for these patients is substantial. Establishing and adhering to best practice models may improve outcome, but requires careful coordination and monitoring. In 2013 our Heart Center began a process to build a comprehensive Single Ventricle Team designed to target these difficult issues. Comprehensive Single Ventricle Team in 2014 was begun, to standardize care for children with single ventricle heart defects from diagnosis to adulthood within our institution. The team is a multidisciplinary group of providers committed to improving outcomes and quality of life for children with single ventricle heart defects, all functioning within the medical home of our heart center. Standards of care were developed and implemented in five target areas to standardize medical management and patient and family support. Under the team 100 patients have been cared for. Since 2014 a decrease in interstage mortality for HLHS were seen. Using a team approach and the tools of Quality Improvement they have been successful in reaching high protocol compliance for each of these areas. This article describes the process of building a successful Single Ventricle team, our initial results, and lessons learned. Additional study is ongoing to demonstrate the effects of these interventions on patient outcomes. © 2017 Wiley Periodicals, Inc.
1976-04-15
System, Dual-System, Single-Mode, and Dual-Mode configurations. Tests were conducted to determine the feasibility of incorporating modular hardware on a...and 11-1/2 feet OFF-CENTER with the BAK-12 configured in the Single and Dual Mode to determine the effect of engaging the aircraft arresting-hook...cable OFF-CENTER. 90,000- pound deadload arrestments were conducted ON-CENTER in the Dual Mode to determine system performance with high-energy
NASA Astrophysics Data System (ADS)
Costantini, J. M.; Beuneu, F.
We have used electron spin resonance spectroscopy to study the defects induced in yttria-stabilized zirconia (YSZ) single crystals by 2.5-MeV electron irradiations. Two paramagnetic centers are produced: the first one with an axial <111> symmetry is similar to the trigonal Zr3+ electron center (T center) found after X-ray irradiation or thermo-chemical reduction, whereas the second one is a new oxygen hole center with an axial <100> symmetry different from the orthorhombic O- center induced by X-ray irradiation. At a fluence around 10(18) e/cm(2) , both centers are bleached out near 600 K, like the corresponding X-ray induced defects. At a fluence around 10(19) e/cm(2) , defects are much more stable, since complete thermal bleaching occurs near 1000 K. Accordingly, ageing of as-irradiated samples shows that high-dose defects at more stable than the low-dose ones.
NASA's Single-Pilot Operations Technical Interchange Meeting: Proceedings and Findings
NASA Technical Reports Server (NTRS)
Comerford, Doreen; Brandt, Summer L.; Lachter, Joel B.; Wu, Shu-Chieh; Mogford, Richard H.; Battiste, Vernol; Johnson, Walter W.
2013-01-01
Researchers at the National Aeronautics and Space Administration (NASA) Ames Research Center and Langley Research Center are jointly investigating issues associated with potential concepts, or configurations, in which a single pilot might operate under conditions that are currently reserved for a minimum of two pilots. As part of early efforts, NASA Ames Research Center hosted a technical interchange meeting in order to gain insight from members of the aviation community regarding single-pilot operations (SPO). The meeting was held on April 10-12, 2012 at NASA Ames Research Center. Professionals in the aviation domain were invited because their areas of expertise were deemed to be directly related to an exploration of SPO. NASA, in selecting prospective participants, attempted to represent various relevant sectors within the aviation domain. Approximately 70 people representing government, academia, and industry attended. A primary focus of this gathering was to consider how tasks and responsibilities might be re-allocated to allow for SPO.
Nitrogen-vacancy centers in diamond: nanoscale sensors for physics and biology.
Schirhagl, Romana; Chang, Kevin; Loretz, Michael; Degen, Christian L
2014-01-01
Crystal defects in diamond have emerged as unique objects for a variety of applications, both because they are very stable and because they have interesting optical properties. Embedded in nanocrystals, they can serve, for example, as robust single-photon sources or as fluorescent biomarkers of unlimited photostability and low cytotoxicity. The most fascinating aspect, however, is the ability of some crystal defects, most prominently the nitrogen-vacancy (NV) center, to locally detect and measure a number of physical quantities, such as magnetic and electric fields. This metrology capacity is based on the quantum mechanical interactions of the defect's spin state. In this review, we introduce the new and rapidly evolving field of nanoscale sensing based on single NV centers in diamond. We give a concise overview of the basic properties of diamond, from synthesis to electronic and magnetic properties of embedded NV centers. We describe in detail how single NV centers can be harnessed for nanoscale sensing, including the physical quantities that may be detected, expected sensitivities, and the most common measurement protocols. We conclude by highlighting a number of the diverse and exciting applications that may be enabled by these novel sensors, ranging from measurements of ion concentrations and membrane potentials to nanoscale thermometry and single-spin nuclear magnetic resonance.
[Topiramate in substance-related and addictive disorders].
Cohen, Johan; Dervaux, Alain; Laqueille, Xavier
2014-09-01
Drug treatments used in substance use disorders are not effective in all patients. To assess the effectiveness of topiramate use in the treatment of substance use disorders. Medline database from January 1966 to December 2013, Cochrane database and clinicaltrials.gov. We used keywords topiramate, addiction, substance abuse, alcohol, tobacco, nicotine, cocaine, methamphetamine, opiate, heroin, benzodiazepine, cannabis, bulimia nervosa, binge eating disorder, gambling. All clinical trials were included. Animal trials, laboratory tests, reviews, answers to writers, case-reports, case series and publications unrelated to the topic were excluded. Twenty-eight articles investigating the efficacy of topiramate in substance use were included. In alcohol-related disorder, several trials and a meta-analysis showed a reduction of days of consumption. In a single-center trial on tobacco-related disorder, topiramate was not found effective in reducing the carbon monoxide expired. In cocaine-related disorder, one single-center trial showed a reduction of days of consumption and two single-center trials have found a trend in favour of topiramate. In alcohol and cocaine co-dependency, a single-center trial found a trend in favour of topiramate. In methamphetamine-related disorder, a multicenter trial found a trend in favour of topiramate. In bulimia nervosa, two single-center trials showed a reduction in binge eating and compensatory behaviours. In binge eating disorder, several trials showed a reduction of binge eating and weight. In gambling, one single-center trial did not show any significant results. There were no randomized controlled trials found in opioid-related disorder, benzodiazepines-related disorder, and cannabis-related disorder. Definition of abstinence and methods to assess the efficacy of topiramate differed between trials. The methodological quality of included trials was variable, especially with no double-blind procedure in eight trials. Topiramate showed interest mainly in alcoholism, binge eating disorder and bulimia nervosa. No definitive conclusions can be reached for other substance use disorders such as nicotine dependence, cocaine dependence, amphetamine dependence or cannabis dependence and for gambling. Copyright © 2014 Elsevier Masson SAS. All rights reserved.
Single-molecule conductance studies of photo-active and photochromic molecules
NASA Astrophysics Data System (ADS)
Tam, E. S.; Parks, J. J.; Santiago-Berrios, M. B.; Zhong, Y.-W.; Abruna, H. D.; Ralph, D. C.
2010-03-01
We perform statistical measurements of single molecule conductance in repeatedly-formed metal-molecule-metal junctions at room temperature. Our results on diaminoalkanes are consistent with those reported by the Venkataraman group. We focus on photo-active and photochromic molecules, including a series of transition-metal complexes with different metal centers and endgroups. We compare the trend in conductance across the family of complexes with that expected from electrochemical measurements. We will also report initial results on the voltage dependence of single-molecule conductances and the effects of optical excitations.
An education initiative modifies opinions of hemodialysis nurses towards home dialysis.
Phillips, Matthew; Wile, Colleen; Bartol, Carolyn; Stockman, Cynthia; Dhir, Minakshi; Soroka, Steven D; Hingwala, Jay; Bargman, Joanne M; Chan, Christopher T; Tennankore, Karthik K
2015-01-01
It has been shown that in-center hemodialysis (HD) nurses prefer in-center HD for patients with certain characteristics; however it is not known if their opinions can be changed. To determine if an education initiative modified the perceptions of in-center HD nurses towards home dialysis. Cross-sectional survey of in-center HD nurses before and after a three hour continuing nursing education (CNE) initiative. Content of the CNE initiative included a didactic review of benefits of home dialysis, common misconceptions about patient eligibility, cost comparisons of different modalities and a home dialysis patient testimonial video. All in-center HD nurses (including those working in satellite dialysis units) affiliated with a single academic institution. Survey themes included perceived barriers to home dialysis, preferred modality (home versus in-center HD), ideal modality distribution in the local program, awareness of home dialysis and patient education about home modalities. Paired comparisons of responses before and after the CNE initiative. Of the 115 in-center HD nurses, 100 registered for the CNE initiative and 89 completed pre and post surveys (89% response rate). At baseline, in-center HD nurses perceived that impaired cognition, poor motor strength and poor visual acuity were barriers to peritoneal dialysis and home HD. In-center HD was preferred for availability of multidisciplinary care and medical personnel in case of catastrophic events. After the initiative, perceptions were more in favor of home dialysis for all patient characteristics, and most patient/system factors. Home dialysis was perceived to be underutilized both at baseline and after the initiative. Finally, in-center HD nurses were more aware of home dialysis, felt better informed about its benefits and were more comfortable teaching in-center HD patients about home modalities after the CNE session. Single-center study. CNE initiatives can modify the opinions of in-center HD nurses towards home modalities and should complement the multitude of strategies aimed at promoting home dialysis.
Kanekar, Neeta; Aruin, Alexander S
2015-04-01
Humans use anticipatory and compensatory postural strategies to maintain and restore balance when perturbed. Inefficient generation and utilization of anticipatory postural adjustments (APAs) is one of the reasons for postural instability. The aim of the study was to investigate the role of training in improvement of APAs and its effect on subsequent control of posture. Thirteen healthy young adults were exposed to predictable external perturbations before and after a single training session consisting of catches of a medicine ball thrown at the shoulder level. 3-D body kinematics, EMG activity of thirteen trunk and lower limb muscles, and ground reaction forces were recorded before and immediately after a single training session. Muscle onsets, EMG integrals, center of pressure (COP), and center of mass (COM) displacements were analyzed during the anticipatory and compensatory phases of postural control. The effect of a single training session was seen as significantly early muscle onsets and larger anticipatory COP displacements. As a result, significantly smaller peak COM displacements were observed after the perturbation indicating greater postural stability. The outcome of this study provides a background for examining the role of training in improvement of APAs and its effect on postural stability in individuals in need. Copyright © 2014 Elsevier Ltd. All rights reserved.
Geramy, Allahyar; Tanne, Kazuo; Moradi, Meisam; Golshahi, Hamid; Farajzadeh Jalali, Yasamin
2016-06-01
The aim of this study was to investigate how very high and very low M/F ratios affect the location of the center of rotation (CRo). A 3D model of a mesiodistal slice of the mandible was used for this purpose. The model comprised the lower right central incisor, its PDL, the spongy and cortical bone, and a bracket on the labial surface of the bracket. A couple of 1N was applied to the bracket slot to find the level of the center of resistance (Cre). In a second stage, we attempted to produce bodily movement by applying the appropriate M/F ratio. M/F ratios of ±100, 200, 400, and 800 were applied to the last tenths of a millimeter of a pre-activated loop. Higher M/F ratios with positive or negative values, at constant force, increased both incisal and apical movements. The change in the tooth inclination before and after force application matched the difference produced by the different M/F ratios. It was found that a single center of rotation can be constructed for any tooth position. However, this single point does not act as the center of rotation during the entire movement. Copyright © 2016 CEO. Published by Elsevier Masson SAS. All rights reserved.
NASA Astrophysics Data System (ADS)
Fuchs, Gregory
2011-03-01
Nitrogen vacancy (NV) center spins in diamond have emerged as a promising solid-state system for quantum information processing and precision metrology at room temperature. Understanding and developing the built-in resources of this defect center for quantum logic and memory is critical to achieving these goals. In the first case, we use nanosecond duration microwave manipulation to study the electronic spin of single NV centers in their orbital excited-state (ES). We demonstrate ES Rabi oscillations and use multi-pulse resonant control to differentiate between phonon-induced dephasing, orbital relaxation, and coherent electron-nuclear interactions. A second resource, the nuclear spin of the intrinsic nitrogen atom, may be an ideal candidate for a quantum memory due to both the long coherence of nuclear spins and their deterministic presence. We investigate coherent swaps between the NV center electronic spin state and the nuclear spin state of nitrogen using Landau-Zener transitions performed outside the asymptotic regime. The swap gates are generated using lithographically fabricated waveguides that form a high-bandwidth, two-axis vector magnet on the diamond substrate. These experiments provide tools for coherently manipulating and storing quantum information in a scalable solid-state system at room temperature. We gratefully acknowledge support from AFOSR, ARO, and DARPA.
Strongly Cavity-Enhanced Spontaneous Emission from Silicon-Vacancy Centers in Diamond
Zhang, Jingyuan Linda; Sun, Shuo; Burek, Michael J.; ...
2018-01-29
Quantum emitters are an integral component for a broad range of quantum technologies, including quantum communication, quantum repeaters, and linear optical quantum computation. Solid-state color centers are promising candidates for scalable quantum optics due to their long coherence time and small inhomogeneous broadening. However, once excited, color centers often decay through phonon-assisted processes, limiting the efficiency of single-photon generation and photon-mediated entanglement generation. Herein, we demonstrate strong enhancement of spontaneous emission rate of a single silicon-vacancy center in diamond embedded within a monolithic optical cavity, reaching a regime in which the excited-state lifetime is dominated by spontaneous emission into themore » cavity mode. We observe 10-fold lifetime reduction and 42-fold enhancement in emission intensity when the cavity is tuned into resonance with the optical transition of a single silicon-vacancy center, corresponding to 90% of the excited-state energy decay occurring through spontaneous emission into the cavity mode. Here, we also demonstrate the largest coupling strength ( g/2π = 4.9 ± 0.3 GHz) and cooperativity ( C = 1.4) to date for color-center-based cavity quantum electrodynamics systems, bringing the system closer to the strong coupling regime.« less
Complete Quantum Control of a Single Silicon-Vacancy Center in a Diamond Nanopillar
NASA Astrophysics Data System (ADS)
Zhang, Jingyuan Linda; Lagoudakis, Konstantinos G.; Tzeng, Yan-Kai; Dory, Constantin; Radulaski, Marina; Kelaita, Yousif; Shen, Zhi-Xun; Melosh, Nicholas A.; Chu, Steven; Vuckovic, Jelena
Coherent quantum control of a quantum bit (qubit) is an important step towards its use in a quantum network. SiV- center in diamond offers excellent physical qualities such as low inhomogeneous broadening, fast photon emission, and a large Debye-Waller factor, while the fast spin manipulation and techniques to extend the spin coherence time are under active investigation. Here, we demonstrate full coherent control over the state of a single SiV- center in a diamond nanopillar using ultrafast optical pulses. The high quality of the chemical vapor deposition grown SiV- centers allows us to coherently manipulate and quasi-resonantly read out the state of the single SiV- center. Moreover, the SiV- centers being coherently controlled are integrated into diamond nanopillar arrays in a site-controlled, individually addressable manner with high yield, low strain, and high spectral stability, which paves the way for scalable on chip optically accessible quantum system in a quantum photonic network. Financial support is provided by the DOE Office of Basic Energy Sciences, Division of Materials Sciences through Stanford Institute for Materials and Energy Sciences (SIMES) under contract DE-AC02-76SF00515.
Strongly Cavity-Enhanced Spontaneous Emission from Silicon-Vacancy Centers in Diamond
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Jingyuan Linda; Sun, Shuo; Burek, Michael J.
Quantum emitters are an integral component for a broad range of quantum technologies, including quantum communication, quantum repeaters, and linear optical quantum computation. Solid-state color centers are promising candidates for scalable quantum optics due to their long coherence time and small inhomogeneous broadening. However, once excited, color centers often decay through phonon-assisted processes, limiting the efficiency of single-photon generation and photon-mediated entanglement generation. Herein, we demonstrate strong enhancement of spontaneous emission rate of a single silicon-vacancy center in diamond embedded within a monolithic optical cavity, reaching a regime in which the excited-state lifetime is dominated by spontaneous emission into themore » cavity mode. We observe 10-fold lifetime reduction and 42-fold enhancement in emission intensity when the cavity is tuned into resonance with the optical transition of a single silicon-vacancy center, corresponding to 90% of the excited-state energy decay occurring through spontaneous emission into the cavity mode. Here, we also demonstrate the largest coupling strength ( g/2π = 4.9 ± 0.3 GHz) and cooperativity ( C = 1.4) to date for color-center-based cavity quantum electrodynamics systems, bringing the system closer to the strong coupling regime.« less
Automatic control of solar power plants
NASA Astrophysics Data System (ADS)
Ermakov, V. S.; Dubilovich, V. M.
1982-02-01
The automatic control of the heliostat field of a 200-MW solar power plant is discussed. The advantages of the decentralized control principle with the solution of a number of individual problems in a single control center are emphasized. The basic requirements on heliostat construction are examined, and possible functional schemes for the automatic control of a heliostat field are described. It is proposed that groups of heliostats can be controlled from a single center and on the basis of a single algorithm.
Campylobacter bacteremia in London: A 44-year single-center study.
O'Hara, Geraldine A; Fitchett, Joseph R A; Klein, John L
2017-09-01
Campylobacter species are a well-recognized but rare cause of bloodstream infection. Here we reviewed 41 cases of Campylobacter bloodstream infection occurring at a single center in London over 44years, comprising 0.2% of all recorded episodes during this time period. Patients had a mean age of 46years and, contrasting with previous reports, nearly 50% of our patients did not have significant comorbidities. Ciprofloxacin resistance increased over the study period with 35% of isolates overall being resistant compared with only 3% exhibiting macrolide resistance. Despite a minority of patients receiving appropriate empirical antibiotic therapy, overall mortality was only 7%. Campylobacter bacteremia remains a rare but significant cause of morbidity with a low associated mortality. Underlying immunosuppressive conditions are common but by no means universal. In our setting, macrolides would be favored as empirical agents to treat suspected Campylobacter enteritis, including cases with associated bacteremia. Copyright © 2017 Elsevier Inc. All rights reserved.
Comparative Study of Impedance Eduction Methods, Part 2: NASA Tests and Methodology
NASA Technical Reports Server (NTRS)
Jones, Michael G.; Watson, Willie R.; Howerton, Brian M.; Busse-Gerstengarbe, Stefan
2013-01-01
A number of methods have been developed at NASA Langley Research Center for eduction of the acoustic impedance of sound-absorbing liners mounted in the wall of a flow duct. This investigation uses methods based on the Pridmore-Brown and convected Helmholtz equations to study the acoustic behavior of a single-layer, conventional liner fabricated by the German Aerospace Center and tested in the NASA Langley Grazing Flow Impedance Tube. Two key assumptions are explored in this portion of the investigation. First, a comparison of results achieved with uniform-flow and shear-flow impedance eduction methods is considered. Also, an approach based on the Prony method is used to extend these methods from single-mode to multi-mode implementations. Finally, a detailed investigation into the effects of harmonic distortion on the educed impedance is performed, and the results are used to develop guidelines regarding acceptable levels of harmonic distortion
Catalytic reduction of dinitrogen to ammonia at a single molybdenum center
Weare, Walter W.; Dai, Xuliang; Byrnes, Matthew J.; Chin, Jia Min; Schrock, Richard R.; Müller, Peter
2006-01-01
Since our discovery of the catalytic reduction of dinitrogen to ammonia at a single molybdenum center, we have embarked on a variety of studies designed to further understand this complex reaction cycle. These include studies of both individual reaction steps and of ligand variations. An important step in the reaction sequence is exchange of ammonia for dinitrogen in neutral molybdenum(III) compounds. We have found that this exchange reaction is first order in dinitrogen and relatively fast (complete in <1 h) at 1 atm of dinitrogen. Variations of the terphenyl substituents in the triamidoamine ligand demonstrate that the original ligand is not unique in its ability to yield successful catalysts. However, complexes that contain sterically less demanding ligands fail to catalyze formation of ammonia from dinitrogen; it is proposed as a consequence of a base-catalyzed decomposition of a diazenido (MoNNH) intermediate. PMID:17085586
The role of CEUS in characterization of superficial lymph nodes: a single center prospective study
de Stefano, Giorgio; Scognamiglio, Umberto; Di Martino, Filomena; Parrella, Roberto; Scarano, Francesco; Signoriello, Giuseppe; Farella, Nunzia
2016-01-01
Accurate lymph node characterization is important in a large number of clinical settings. We evaluated the usefulness of Contrast Enhanced Ultrasound (CEUS) in distinguishing between benign and malignant lymph nodes compared with conventional ultrasonography in the differential diagnosis of superficial lymphadenopathy. We present our experience for 111 patients enrolled in a single center. 111 superficial lymph nodes were selected and only 1 lymph node per patient underwent CEUS. A definitive diagnosis for all lymph nodes was obtained by ultrasonographically guided biopsy and/or excision biopsy. The size of the lymph nodes, the site (neck, axilla, inguinal region) being easily accessible for biopsy, and the US and color Doppler US characteristics guided us in selecting the nodes to be evaluated by CEUS. In our study we identified different enhancement patterns in benign and malignant lymph nodes, with a high degree of diagnostic accuracy for superficial lymphadenopathy in comparison with conventional US. PMID:27191746
NASA Technical Reports Server (NTRS)
Lauenstein, J.-M.; Casey, M. C.; Campola, M. A.; Phan, A. M.; Wilcox, E. P.; Topper, A. D.; Ladbury, R. L.
2017-01-01
This study was being undertaken to determine the single event effect susceptibility of the commercial Vishay 60-V TrenchFET power MOSFET. Heavy-ion testing was conducted at the Texas AM University Cyclotron Single Event Effects Test Facility (TAMU) and the Lawrence Berkeley National Laboratory BASE Cyclotron Facility (LBNL). In addition, initial 200-MeV proton testing was conducted at Massachusetts General Hospital (MGH) Francis H. Burr Proton Beam Therapy Center. Testing was performed to evaluate this device for single-event effects from lower-LET, lighter ions relevant to higher risk tolerant space missions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hargreaves, L. R.; Colyer, C.; Stevenson, M. A.
A number of previous studies have suggested the possibility of two-center interference effects in the single ionization of diatomic molecules such as H{sub 2} and N{sub 2}. While interference effects have been successfully observed in the ionization of H{sub 2}, to date evidence for interference in N{sub 2} ionization has yet to be conclusively demonstrated. This study presents triply differential cross sections for electron impact ionization of N{sub 2}, measured using the (e,2e) technique. The data are probed for signatures of two-center interference effects. Evidence for interference manifesting in the cross sections is observed.
EPR and photoluminescence study of irradiated anion-defective alumina single crystals
NASA Astrophysics Data System (ADS)
Kortov, V. S.; Ananchenko, D. V.; Konev, S. F.; Pustovarov, V. A.
2017-09-01
Electron paramagnetic resonance (EPR) and photoluminescence (PL) spectra of anion-defective alumina single crystals were measured. Exposure to a dose 10 Gy-1 kGy causes isotropic EPR signal of a complex form, this signal contains narrow and broad components. At the same time, in the PL spectrum alongside with a band of F+-centers (3.8 eV) an additional emission band with the maximum of 2.25 eV is registered. This band corresponds to aggregate F22+-centers which were create under irradiation. By comparing measurements in EPR and PL spectra with further stepped annealing in the temperature range of 773-1473 K of the samples exposed to the same doses, we were able to conclude that a narrow component of isotropic EPR signal is associated with the formation of paramagnetic F22+-centers under irradiation. A wide component can be caused by deep hole traps which are created by a complex defect (VAl2- - F+) with a localized hole.
Magnetization measurements of Sr2RuO4-Ru eutectic microplates using dc-SQUIDs
NASA Astrophysics Data System (ADS)
Nago, Y.; Sakuma, D.; Ishiguro, R.; Kashiwaya, S.; Nomura, S.; Kono, K.; Maeno, Y.; Takayanagi, H.
2018-03-01
We report magnetization measurements of Sr2RuO4-Ru eutectic microplates using micro-dc-SQUIDs. Sr2RuO4 is considered as a chiral p-wave superconductor and hence Sr2RuO4-Ru eutectic becomes in an unstable state with a superconducting phase frustration between a chiral p-wave state of Sr2RuO4 and a s-wave state of Ru. To compensate the frustration, a single quantum vortex is spontaneously formed at the center of the Ru inclusion at sufficiently low temperatures. However, such a spontaneous vortex state has not been experimentally observed yet. In this study, we prepared a micro-dc-SQUID and a Sr2RuO4-Ru eutectic microplate containing a single Ru-inclusion at the center of the microplate. We performed magnetization measurements down below the superconducting transition temperature of the Ru inclusion to investigate the spontaneous Ru-center vortex state.
Hydrogen centers and the conductivity of In 2O 3 single crystals
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yin, Weikai; Smithe, Kirby; Weiser, Philip
2015-02-24
A series of infrared absorption experiments and complementary theory have been performed in order to determine the properties of OH and OD centers in In 2O 3 single crystals. Annealing In 2O 3 samples in H 2 or D 2 at temperatures near 450°C produces an n-type layer ≈0.06mm thick with an n-type doping of 1.6×1019 cm -3. The resulting free-carrier absorption is correlated with an OH center with a vibrational frequency of 3306 cm -1 that we associate with interstitial H +. Additional O-H (O-D) vibrational lines are assigned to metastable configurations of the interstitial H +(D +) centermore » and complexes of H (D) with In vacancies. In addition, unlike other oxides studied recently where H trapped at an oxygen vacancy is the dominant shallow donor (ZnO and SnO 2, for example), interstitial H + is found to be the dominant H-related shallow donor in In 2O 3.« less
Williams, Richard V.; Zak, Victor; Ravishankar, Chitra; Altmann, Karen; Anderson, Jeffrey; Atz, Andrew M.; Dunbar-Masterson, Carolyn; Ghanayem, Nancy; Lambert, Linda; Lurito, Karen; Medoff-Cooper, Barbara; Margossian, Renee; Pemberton, Victoria L.; Russell, Jennifer; Stylianou, Mario; Hsu, Daphne
2011-01-01
Objectives To describe growth patterns in infants with single ventricle physiology and determine factors influencing growth. Study design Data from 230 subjects enrolled in the Pediatric Heart Network Infant Single Ventricle Enalapril Trial were used to assess factors influencing change in weight-for-age z-score (Δz) from study enrollment (0.7 ± 0.4 months) to pre-superior cavopulmonary connection (SCPC) (5.1 ± 1.8 months, period 1), and pre-SCPC to final study visit (14.1 ± 0.9 months, period 2). Predictor variables included patient characteristics, feeding regimen, clinical center, and medical factors during neonatal (period 1) and SCPC hospitalizations (period 2). Univariate regression analysis was performed, followed by backward stepwise regression and bootstrapping reliability to inform a final multivariable model. Results Weights were available for 197/230 subjects for period 1 and 173/197 for period 2. For period 1, greater gestational age, younger age at study enrollment, tube feeding at neonatal discharge, and clinical center were associated with a greater negative Δz (poorer growth) in multivariable modeling (adjusted R2 = 0.39, p < 0.001). For period 2, younger age at SCPC and greater daily caloric intake were associated with greater positive Δz (better growth) (R2 = 0.10, p = 0.002). Conclusions Aggressive nutritional support and earlier SCPC are modifiable factors associated with a favorable change in weight-for-age z-score. PMID:21784436
Riordan, Coleman P; Orbach, Darren B; Smith, Edward R; Scott, R Michael
2018-06-01
OBJECTIVE The most significant adverse outcome of intracranial hemorrhage from an arteriovenous malformation (AVM) is death. This study reviews a single-center experience with pediatric AVMs to quantify the incidence and characterize clinical and radiographic factors associated with sudden death from the hemorrhage of previously undiagnosed AVMs in children. METHODS A single-center database review of the period from 2006 to 2017 identified all patients with a first-time intracranial hemorrhage from a previously undiagnosed AVM. Clinical and radiographic data were collected and compared between patients who survived to hospital discharge and those who died at presentation. RESULTS A total of 57 patients (average age 10.8 years, range 0.1-19 years) presented with first-time intracranial hemorrhage from a previously undiagnosed AVM during the study period. Of this group, 7/57 (12%) patients (average age 11.5 years, range 6-16 years) suffered hemorrhages that led directly to their deaths. Compared to the cohort of patients who survived their hemorrhage, patients who died were 4 times more likely to have an AVM in the posterior fossa. No clear pattern of antecedent triggering activity (sports, trauma, etc.) was identified, and 3/7 (43%) experienced cardiac arrest in the prehospital setting. Surviving patients were ultimately treated with resection of the AVM in 42/50 (84%) of cases. CONCLUSIONS Children who present with hemorrhage from a previously undiagnosed intracranial AVM had a 12% chance of sudden death in our single-institution series of pediatric cerebrovascular cases. Clinical triggers of hemorrhage are unpredictable, but subsequent radiographic evidence of a posterior fossa AVM was present in 57% of fatal cases, and all fatal cases were in locations with high risk of potential herniation. These data support a proactive, aggressive approach toward definitive treatment of AVMs in children.
Peschel, G; Moleda, L; Baier, L; Selgrad, M; Schmid, S; Scherer, M N; Müller, M; Weigand, K
2018-06-01
Patients after liver transplantation (LT) with hepatitis C virus (HCV) infection often suffer from renal or hepatic impairment. Treating patients after LT with direct-acting antivirals (DAA) might result in decreasing renal function due to interaction of DAA and immunosuppressive therapy. In this single-center study we analyzed clinical parameters of 18 HCV-infected patients treated with DAA therapy after LT. The primary end points were change of renal function (glomerular filtration rate) and sustained virologic response 12 weeks after therapy (SVR12). For secondary end points, we investigated the influence of DAA therapy on transaminases, bilirubin, international normalized ratio, noninvasive fibrosis measurement, and Model for End-Stage Liver Disease (MELD) score. Five out of 18 patients treated with DAA suffered from renal impairment stage 2, and 7 patients of renal impairment stage 3. Renal function at SVR12 was not influenced by preexisting renal impairment (P > .5), type of immunosuppressant (P > .5), or type of DAA regimen (P > .5). All patients reached SVR12. The levels of transaminases and bilirubin declined rapidly, as expected. Ten out of 18 patients already suffered from cirrhosis or liver fibrosis >F3 according to noninvasive measurement before initiation of treatment. Single-point acoustic radiation force impulse imaging improved in 9 patients (P = .012). In 7 patients, MELD score improved owing to the decrease of bilirubin levels. In 6 patients it worsened. DAA therapy in LT patients was effective and safe in this single-center real-life cohort. Renal function was not influenced by the administered drug combinations, even in patients with preexisting renal impairment. Copyright © 2018. Published by Elsevier Inc.
Initial Comparison of Single Cylinder Stirling Engine Computer Model Predictions with Test Results
NASA Technical Reports Server (NTRS)
Tew, R. C., Jr.; Thieme, L. G.; Miao, D.
1979-01-01
A Stirling engine digital computer model developed at NASA Lewis Research Center was configured to predict the performance of the GPU-3 single-cylinder rhombic drive engine. Revisions to the basic equations and assumptions are discussed. Model predictions with the early results of the Lewis Research Center GPU-3 tests are compared.
Toward efficient fiber-based quantum interface (Conference Presentation)
NASA Astrophysics Data System (ADS)
Soshenko, Vladimir; Vorobyov, Vadim V.; Bolshedvorsky, Stepan; Lebedev, Nikolay; Akimov, Alexey V.; Sorokin, Vadim; Smolyaninov, Andrey
2016-04-01
NV center in diamond is attracting a lot of attention in quantum information processing community [1]. Been spin system in clean and well-controlled environment of diamond it shows outstanding performance as quantum memory even at room temperature, spin control with single shot optical readout and possibility to build up quantum registers even on single NV center. Moreover, NV centers could be used as high-resolution sensitive elements of detectors of magnetic or electric field, temperature, tension, force or rotation. For all of these applications collection of the light emitted by NV center is crucial point. There were number of approaches suggested to address this issue, proposing use of surface plasmoms [2], manufacturing structures in diamond [3] etc. One of the key feature of any practically important interface is compatibility with the fiber technology. Several groups attacking this problem using various approaches. One of them is placing of nanodiamonds in the holes of photonic crystal fiber [4], another is utilization of AFM to pick and place nanodiamond on the tapered fiber[5]. We have developed a novel technique of placing a nanodiamond with single NV center on the tapered fiber by controlled transfer of a nanodiamond from one "donor" tapered fiber to the "target" clean tapered fiber. We verify our ability to transfer only single color centers by means of measurement of second order correlation function. With this technique, we were able to double collection efficiency of confocal microscope. The majority of the factors limiting the collection of photons via optical fiber are technical and may be removed allowing order of magnitude improved in collection. We also discuss number of extensions of this technique to all fiber excitation and integration with nanostructures. References: [1] Marcus W. Doherty, Neil B. Manson, Paul Delaney, Fedor Jelezko, Jörg Wrachtrup, Lloyd C.L. Hollenberg , " The nitrogen-vacancy colour centre in diamond," Physics Reports, vol. 528, no. 1, p. 1-45, 2013. [2] A.V. Akimov, A. Mukherjee, C.L. Yu, D.E. Chang, A.S. Zibrov, P.R. Hemmer, H. Park and M.D. Lukin, "Generation of single optical plasmons in metallic nanowires coupled to quantum dots," Nature, vol. 450, p. 402-406, 2007. [3] Michael J. Burek , Yiwen Chu, Madelaine S.Z. Liddy, Parth Patel, Jake Rochman , Srujan Meesala, Wooyoung Hong, Qimin Quan, Mikhail D. Lukin and Marko Loncar High quality-factor optical nanocavities in bulk single-crystal diamond, Nature communications 6718 (2014) [4] Tim Schroder, Andreas W. Schell, Gunter Kewes, Thomas Aichele, and Oliver Benson Fiber-Integrated Diamond-Based Single Photon Source, Nano Lett. 2011, 11, 198-202 [5]Lars Liebermeister, et. al. "Tapered fiber coupling of single photons emitted by a deterministically positioned single nitrogen vacancy center", Appl. Phys. Lett. 104, 031101 (2014)
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-02
... Project Clearance Liaison, Science Policy and Evaluation Branch, OSPPC, NIMH, NIH, Neuroscience Center... NIMH-sponsored clinical research studies that plan to enroll 150 or more human subjects in a single study. Clinical studies can have difficulty recruiting, and accurate and timely reporting is the best...
Gibbons, Raymond J; Askew, J Wells; Hodge, David; Miller, Todd D
2010-03-01
The purpose of this study was to apply published appropriateness criteria for single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI) in a single academic medical center to determine if the percentage of inappropriate studies was changing over time. In a previous study, we applied the American College of Cardiology Foundation/American Society of Nuclear Cardiology (ASNC) appropriateness criteria for stress SPECT MPI and reported that 14% of stress SPECT studies were performed for inappropriate reasons. Using similar methodology, we retrospectively examined 284 patients who underwent stress SPECT MPI in October 2006 and compared the findings to the previous cohort of 284 patients who underwent stress SPECT MPI in May 2005. The indications for testing in the 2 cohorts were very similar. The overall level of agreement in characterizing categories of appropriateness between 2 experienced cardiovascular nurse abstractors was good (kappa = 0.68), which represented an improvement from our previous study (kappa = 0.56). There was a significant change between May 2005 and October 2006 in the overall classification of categories for appropriateness (P = .024 by chi(2) statistic). There were modest, but insignificant, increases in the number of patients who were unclassified (15% in the current study vs 11% previously), appropriate (66% vs 64%), and uncertain (12% vs 11%). Only 7% of the studies in the current study were inappropriate, which represented a significant (P = .004) decrease from the 14% reported in the 2005 cohort. In the absence of any specific intervention, there was a significant change in the overall classification of SPECT appropriateness in an academic medical center over 17 months. The only significant difference in individual categories was a decrease in inappropriate studies. Additional measurements over time will be required to determine if this trend is sustainable or generalizable.
Economic Burden of Road Traffic Accidents; Report from a Single Center from South Eastern Iran
Sargazi, Aliyeh; Sargazi, Atefeh; Nadakkavukaran Jim, Prigil Kumar; Danesh, HoseinAli; Aval, ForoughSargolzaee; Kiani, Zohre; Lashkarinia, AmirHosein; Sepehri, Zahra
2016-01-01
Objective: To determine the economic burden of road traffic accidents (RTAs) in patients admitted to a single center in south eastern Iran. Methods: This cross-sectional study was conducted in Amir-Al-Momenin hospital of Zabol affiliated with Zabol University of Medical Sciences during a 12-month period from April 2012 to April 2013. All the RTAs patients who were admitted to our emergency department were included. The direct expenses of hospital care were recorded according to their medical charts and the accountant registration information. Data are presented according to different RTAs characteristics. Results: Overall 1155 patients were included in the current study with mean age of 36.7 ± 5.14 years among whom there were 673(58.3%) men and 482 (41.7%) women. The annual incidence of RTAs were calculated to be 288 per 100,000 population. The RTAs economic burden in our center was 589,448.49 USD which accounted for 10.4% of total hospital expenses during the study period. The money spend on RTAs in our center was 130 times more than gross national income per capita. Cost of each patient in road traffic was 15 times more than cost of an average patient of the hospital in other sections. Conclusion: With considerable high ratio of accidents in Zabol, proper intervention is needed for controlling and preventing RTAs in order to decrease its injuries, impact and the associated economic burden. PMID:27162926
Nitrogen and silicon defect incorporation during homoepitaxial CVD diamond growth on (111) surfaces
Moore, Samuel L.; Vohra, Yogesh K.
2015-01-01
Chemical Vapor Deposited (CVD) diamond growth on (111)-diamond surfaces has received increased attention lately because of the use of N-V related centers in quantum computing as well as application of these defect centers in sensing nano-Tesla strength magnetic fields. We have carried out a detailed study of homoepitaxial diamond deposition on (111)-single crystal diamond (SCD) surfaces using a 1.2 kW microwave plasma CVD (MPCVD) system employing methane/hydrogen/nitrogen/oxygen gas phase chemistry. We have utilized Type Ib (111)-oriented single crystal diamonds as seed crystals in our study. The homoepitaxially grown diamond films were analyzed by Raman spectroscopy, Photoluminescence Spectroscopy (PL), X-ray Photoelectronmore » Spectroscopy (XPS), Scanning Electron Microscopy (SEM) and Atomic Force Microscopy (AFM). The nitrogen concentration in the plasma was carefully varied between 0 and 1500 ppm while a ppm level of silicon impurity is present in the plasma from the quartz bell jar. The concentration of N-V defect centers with PL zero phonon lines (ZPL) at 575nm and 637nm and the Si-defect center with a ZPL at 737nm were experimentally detected from a variation in CVD growth conditions and were quantitatively studied. As a result, altering nitrogen and oxygen concentration in the plasma was observed to directly affect N-V and Si-defect incorporation into the (111)-oriented diamond lattice and these findings are presented.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jiang, Qianqing; Liu, Dongqi; Liu, Gangqin
2014-07-28
Sources of single photons are of fundamental importance in many applications as to provide quantum states for quantum communication and quantum information processing. Color centers in diamond are prominent candidates to generate and manipulate quantum states of light, even at room temperature. However, the efficiency of photon collection of the color centers in bulk diamond is greatly reduced by refraction at the diamond/air interface. To address this issue, diamond structuring has been investigated by various methods. Among them, focused-ion-beam (FIB) direct patterning has been recognized as the most favorable technique. But it has been noted that diamond tends to presentmore » significant challenges in FIB milling, e.g., the susceptibility of forming charging related artifacts and topographical features. In this work, periodically-positioned-rings and overlay patterning with stagger-superimposed-rings were proposed to alleviate some problems encountered in FIB milling of diamond, for improved surface morphology and shape control. Cross-scale network and uniform nanostructure arrays have been achieved in single crystalline diamond substrates. High quality diamond solid immersion lens and nanopillars were sculptured with a nitrogen-vacancy center buried at the desired position. Compared with the film counterpart, an enhancement of about ten folds in single photon collection efficiency was achieved with greatly improved signal to noise ratio. All these results indicate that FIB milling through over-lay patterning could be an effective approach to fabricate diamond structures, potentially for quantum information studies.« less
Bone metabolism in oxalosis: a single-center study using new imaging techniques and biomarkers.
Bacchetta, Justine; Fargue, Sonia; Boutroy, Stéphanie; Basmaison, Odile; Vilayphiou, Nicolas; Plotton, Ingrid; Guebre-Egziabher, Fitsum; Dohin, Bruno; Kohler, Rémi; Cochat, Pierre
2010-06-01
The deposition of calcium oxalate crystals in the kidney and bone is a hallmark of primary hyperoxaluria type 1 (PH1). We report here an evaluation of the bone status of 12 PH1 children based on bone biomarkers [parathyroid hormone, vitamin D, fibroblast growth factor 23 (FGF23)] and radiological assessments (skeletal age, three-dimensional high-resolution peripheral quantitative computed tomography, HR-pQCT) carried out within the framework of a cross-sectional single-center study. The controls consisted of healthy and children with chronic kidney disease already enrolled in local bone and mineral metabolism studies. The mean age (+ or - standard deviation) age of the patients was 99 (+ or - 63) months. Six children suffered from fracture. Bone maturation was accelerated in five patients, four of whom were <5 years. The combination of new imaging techniques and biomarkers highlighted new and unexplained features of PH1: advanced skeletal age in young PH1 patients, increased FGF23 levels and decreased total volumetric bone mineral density with bone microarchitecture alteration.
Gu, Jiande; Wang, Jing; Leszczynski, Jerzy
2014-01-30
Computational chemistry approach was applied to explore the nature of electron attachment to cytosine-rich DNA single strands. An oligomer dinucleoside phosphate deoxycytidylyl-3',5'-deoxycytidine (dCpdC) was selected as a model system for investigations by density functional theory. Electron distribution patterns for the radical anions of dCpdC in aqueous solution were explored. The excess electron may reside on the nucleobase at the 5' position (dC(•-)pdC) or at the 3' position (dCpdC(•-)). From comparison with electron attachment to the cytosine related DNA fragments, the electron affinity for the formation of the cytosine-centered radical anion in DNA is estimated to be around 2.2 eV. Electron attachment to cytosine sites in DNA single strands might cause perturbations of local structural characteristics. Visible absorption spectroscopy may be applied to validate computational results and determine experimentally the existence of the base-centered radical anion. The time-dependent DFT study shows the absorption around 550-600 nm for the cytosine-centered radical anions of DNA oligomers. This indicates that if such species are detected experimentally they would be characterized by a distinctive color.
Effects of Collaborative Online Learning on EFL Learners' Writing Performance and Self-Efficacy
ERIC Educational Resources Information Center
Tai, Hung-Cheng
2016-01-01
This study explored the effects of collaborative writing instruction on undergraduate nursing students' writing performance and self-efficacy beliefs within an online learning system. A single-group experimental study utilized two instruments, the NCEEC (National College Entrance Examination Center) writing grading criteria (the SRCT) and a…
Jain, Aditi; Asrani, Hemant; Singhal, Abhinav Chand; Bhatia, Taranjeet Kaur; Sharma, Vaibhav; Jaiswal, Pragya
2016-01-01
Aims: To compare the canal transportation, centering ability, and remaining dentin thickness of WaveOne and ProTaper systems using cone beam computed tomography. Subjects and Methods: Forty extracted human single-rooted premolars were used in the present study. Preinstrumentation scanning of all teeth was taken; canal curvatures were calculated, and the samples were randomly divided into two groups, with twenty samples in each group; one group was instrumented with WaveOne system and the other group with ProTaper rotary system. Postinstrumentation scans were performed, and the two scans were compared to determine canal transportation, centering ability, and remaining dentin thickness at 3 mm, 6 mm, and 9 mm from the root apex. Statistical Analysis Used: Student's unpaired t-test. Results: Using Student's unpaired t-test, results were as follows: for canal transportation, Group 1 showed significant difference at 3 mm and 6 mm and insignificant difference at 9 mm while Group 2 showed insignificant difference in all the three regions. For centering ability and remaining dentin thickness, Group 1 showed insignificant difference at 3 mm and 9 mm while significant difference at 6 mm was obtained. When comparison of remaining dentin thickness was done at three levels using two groups WaveOne and ProTaper, there was no significant difference between two groups. Conclusions: (1) WaveOne single reciprocation file system respected better canal anatomy better than ProTaper. (2) Individually, centering ability of WaveOne was better at 3 mm, 6 mm, and 9 mm levels. (3) However, ProTaper individually was better centered at 3 mm (apical third) and 9 mm (coronal 3rd) levels than 6 mm level (middle third). PMID:27656063
Cai, Guilan; Wang, Yini; Liu, Xiaojing; Han, Yanfei; Wang, Zhao
2017-08-01
Hemophagocytic lymphohistiocytosis (HLH) is a rare multisystem disorder characterized by proliferation and diffuse infiltration multiple organs with histiocytes, including the central nervous system (CNS). Neurological manifestations of HLH have been recognized in different studies with children, but they remain relatively ill-defined in adults with HLH. From March 2008 to October 2014, 289 adult patients with HLH were admitted to our center. Clinical, radiological, and cerebral spinal fluid (CSF) data of the patients with CNS involvement were reviewed, and a retrospective study in our single-center was carried out. CNS involvement was observed in 29 patients (10%) either in their diagnosis process or during disease course. CNS symptoms included disturbance of consciousness, cranial nerve palsies, seizures, headache, limb paralysis, irritability, meningism, and memory loss. CSF analysis was conducted in 17 patients (59%). Among them, 11 patients (65%) were reported as having abnormal CSF. Neuroradiological studies were performed in 25 patients (86%). Among the 13 cases that underwent CT scan, one patient hemorrhaged. Single or multiple hypodense foci were detected in the other 2 patients. Magnetic resonance imaging (MRI) abnormalities were found in 15 patients, including focal lesions in cortical and adjacent subcortical regions with or without variable nodular or ring contrast-enhancement, multiple lesions in white matter, diffuse white matter signal changes, and meningeal enhancement. Basal ganglia, cerebellum, and brainstem lesions were also observed. CNS involvement could also be found in adult patients with HLH, but not as frequent as it was in children. The clinical manifestations could be diversified. By carrying out rigorous CNS examinations, an early diagnosis could be made and it was of the utmost importance for the prevention of further lesions.
High-spin europium and gadolinium centers in yttrium-aluminum garnet
NASA Astrophysics Data System (ADS)
Vazhenin, V. A.; Potapov, A. P.; Asatryan, G. R.; Uspenskaya, Yu. A.; Petrosyan, A. G.; Fokin, A. V.
2016-08-01
Electron-spin resonance spectra of Eu2+ and Gd3+ centers substituting Y3+ ions in single-crystal yttrium-aluminum garnet have been studied and the parameters of their rhombic spin Hamiltonian have been determined. The fine-structure parameters of the above ions have been calculated in the superposition model disregarding changes in the angular coordinates of the ligand environment of the impurity defect thus demonstrating the necessity of taking these changes into account.
Bartke, Rebecca M; Cameron, Elizabeth L; Cristie-David, Ajitha S; Custer, Thomas C; Denies, Maxwell S; Daher, May; Dhakal, Soma; Ghosh, Soumi; Heinicke, Laurie A; Hoff, J Damon; Hou, Qian; Kahlscheuer, Matthew L; Karslake, Joshua; Krieger, Adam G; Li, Jieming; Li, Xiang; Lund, Paul E; Vo, Nguyen N; Park, Jun; Pitchiaya, Sethuramasundaram; Rai, Victoria; Smith, David J; Suddala, Krishna C; Wang, Jiarui; Widom, Julia R; Walter, Nils G
2015-05-01
Four days after the announcement of the 2014 Nobel Prize in Chemistry for "the development of super-resolved fluorescence microscopy" based on single molecule detection, the Single Molecule Analysis in Real-Time (SMART) Center at the University of Michigan hosted a "Principles of Single Molecule Techniques 2014" course. Through a combination of plenary lectures and an Open House at the SMART Center, the course took a snapshot of a technology with an especially broad and rapidly expanding range of applications in the biomedical and materials sciences. Highlighting the continued rapid emergence of technical and scientific advances, the course underscored just how brightly the future of the single molecule field shines. © 2014 Wiley Periodicals, Inc.
Controlling Spin Coherence with Semiconductor Nanostructures
NASA Astrophysics Data System (ADS)
Awschalom, David D.
We present two emerging opportunities for manipulating and communicating coherent spin states in semiconductors. First, we show that semiconductor microcavities offer unique means of controlling light-matter interactions in confined geometries, resulting in a wide range of applications in optical communications and inspiring proposals for quantum information processing and computational schemes. Studies of spin dynamics in microcavities — a new and promising research field — have revealed novel effects such as polarization beats, stimulated spin scattering, and giant Faraday rotation. Here, we study the electron spin dynamics in optically-pumped GaAs microdisk lasers with quantum wells and interface-fluctuation quantum dots in the active region. In particular, we examine how the electron spin dynamics are modified by the stimulated emission in the disks, and observe an enhancement of the spin coherence time when the optical excitation is in resonance with a high quality (Q ~ 5000) lasing mode.1 This resonant enhancement, contrary to expectations from the observed trend in the carrier recombination time, is then manipulated by altering the cavity design and dimensions. In analogy to devices based on excitonic coherence, this ability to engineer coherent interactions between electron spins and photons may provide novel pathways towards spin dependent quantum optoelectronics. In a second example, the nitrogen-vacancy (N-V) center in diamond has garnered interest as a room-temperature solid-state system not only for exploring electronic and nuclear spin phenomena but also as a candidate for spin-based quantum information processing. Spin coherence times of up to 50 microseconds have been reported for ensembles of N-V centers and a two-qubit gate utilizing the electron spin of a N-V center and the nuclear spin of a nearby C-13 atom has been demonstrated. Here, we present experiments using angle-resolved magneto-photoluminescence microscopy to investigate anisotropic spin interactions of single N-V centers in diamond at room temperature.2 Negative peaks in the photoluminescence intensity are observed as a function of both magnetic field magnitude and angle, and can be explained by coherent spin precession and anisotropic relaxation at spin-level anticrossings. Additionally, precise field alignment with the symmetry axis of a single N-V center reveals the resonant magnetic dipolar coupling of a single "bright" electron spin of an N-V center to small numbers of "dark" spins of nitrogen defects in its immediate vicinity, which are otherwise undetected by photoluminescence. Most recently, we are exploring the possibility of utilizing this magnetic dipole coupling between bright and dark spins to couple two spatially separated single N-V center spins by means of intermediate nitrogen spins. Note from Publisher: This article contains the abstract only.
Phonon self-energy corrections to non-zero wavevector phonon modes in single-layer graphene
NASA Astrophysics Data System (ADS)
Araujo, Paulo; Mafra, Daniela; Sato, Kentaro; Saito, Richiiro; Kong, Jing; Dresselhaus, Mildred
2012-02-01
Phonon self-energy corrections have mostly been studied theoretically and experimentally for phonon modes with zone-center (q = 0) wave-vectors. Here, gate-modulated Raman scattering is used to study phonons of a single layer of graphene (1LG) in the frequency range from 2350 to 2750 cm-1, which shows the G* and the G'-band features originating from a double-resonant Raman process with q 0. The observed phonon renormalization effects are different from what is observed for the zone-center q = 0 case. To explain our experimental findings, we explored the phonon self-energy for the phonons with non-zero wave-vectors (q 0) in 1LG in which the frequencies and decay widths are expected to behave oppositely to the behavior observed in the corresponding zone-center q = 0 processes. Within this framework, we resolve the identification of the phonon modes contributing to the G* Raman feature at 2450 cm-1 to include the iTO+LA combination modes with q 0 and the 2iTO overtone modes with q = 0, showing both to be associated with wave-vectors near the high symmetry point K in the Brillouin zone.
Plasmon resonance enhanced temperature-dependent photoluminescence of Si-V centers in diamond
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cheng, Shaoheng; State Key Laboratory on Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University, Changchun 130012; Song, Jie
2015-11-23
Temperature dependent optical property of diamond has been considered as a very important factor for realizing high performance diamond-based optoelectronic devices. The photoluminescence feature of the zero phonon line of silicon-vacancy (Si-V) centers in Si-doped chemical vapor deposited single crystal diamond (SCD) with localized surface plasmon resonance (LSPR) induced by gold nanoparticles has been studied at temperatures ranging from liquid nitrogen temperature to 473 K, as compared with that of the SCD counterpart in absence of the LSPR. It is found that with LSPR the emission intensities of Si-V centers are significantly enhanced by factors of tens and the magnitudes ofmore » the redshift (width) of the emissions become smaller (narrower), in comparison with those of normal emissions without plasmon resonance. More interestingly, these strong Si-V emissions appear remarkably at temperatures up to 473 K, while the spectral feature was not reported in previous studies on the intrinsic Si-doped diamonds when temperatures are higher than room temperature. These findings would lead to reaching high performance diamond-based devices, such as single photon emitter, quantum cryptography, biomarker, and so forth, working under high temperature conditions.« less
Characterizing Oscillatory Bursts in Single-Trial EEG Data
NASA Technical Reports Server (NTRS)
Knuth, K. H.; Shah, A. S.; Lakatos, P.; Schroeder, C. E.
2004-01-01
Oscillatory bursts in numerous bands ranging from low (theta) to high frequencies (e.g., gamma) undoubtedly play an important role in cortical dynamics. Largely because of the inadequacy of existing analytic techniques. however, oscillatory bursts and their role in cortical processing remains poorly understood. To study oscillatory bursts effectively one must be able to isolate them and characterize them in the single trial. We describe a series of straightforward analysis techniques that produce useful indices of burst characteristics. First, stimulus-evoked responses are estimated using Differentially Variable Component Analysis (dVCA), and are subtracted from the single-trial. The single-trial characteristics of the evoked responses are stored to identify possible correlations with burst activity. Time-frequency (T-F), or wavelet, analyses are then applied to the single trial residuals. While T-F plots have been used in recent studies to identify and isolate bursts, we go further by fitting each burst in the T-F plot with a two-dimensional Gaussian. This provides a set of burst characteristics, such as, center time. burst duration, center frequency. frequency dispersion. and amplitude, all of which contribute to the accurate characterization of the individual burst. The burst phase can also be estimated. Burst characteristics can be quantified with several standard techniques (e.g.. histogramming and clustering), as well as Bayesian techniques (e.g., blocking) to allow a more parametric description analysis of the characteristics of oscillatory bursts, and the relationships of specific parameters to cortical excitability and stimulus integration.
Reevaluating the two-representation model of numerical magnitude processing.
Jiang, Ting; Zhang, Wenfeng; Wen, Wen; Zhu, Haiting; Du, Han; Zhu, Xiangru; Gao, Xuefei; Zhang, Hongchuan; Dong, Qi; Chen, Chuansheng
2016-01-01
One debate in mathematical cognition centers on the single-representation model versus the two-representation model. Using an improved number Stroop paradigm (i.e., systematically manipulating physical size distance), in the present study we tested the predictions of the two models for number magnitude processing. The results supported the single-representation model and, more importantly, explained how a design problem (failure to manipulate physical size distance) and an analytical problem (failure to consider the interaction between congruity and task-irrelevant numerical distance) might have contributed to the evidence used to support the two-representation model. This study, therefore, can help settle the debate between the single-representation and two-representation models.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Marseglia, L.; Saha, K.; Ajoy, A.
The practical implementation of quantum technologies such as quantum commu- nication and quantum cryptography relies on the development of indistinguishable, robust, and bright single photon sources that works at room temperature. The silicon- vacancy (SiV -) center in diamond has emerged as a possible candidate for a single photon source with all these characteristics. Unfortunately, due to the high refraction index mismatch between diamond and air, color centers in diamond show low photon out-coupling. This drawback can be overcome by fabrication of photonic structures that improve the in-coupling of excitation laser to the diamond defect as well as the out-couplingmore » emission from the color centers. An additional shortcoming is due to the random localization of native defects in the diamond sample. Here we demonstrate deterministic implantation of Si ions with high conversion effciency to single SiV -, targeted to fabricated nanowires. The co-localization of single SiV - defects with the nanostructures yields a ten times higher light coupling effciency as compared to single SiV - in the bulk. This result, with its intrinsic scalability, enables a new class of devices for integrated photonics and quantum information processing.« less
Innovative mechanism for measuring the mass properties of an object
NASA Technical Reports Server (NTRS)
Wolcott, Kedron R.; Graham, Todd A.; Doty, Keith L.
1994-01-01
The Kennedy Space Center Robotics Group recently completed development and testing on a novel approach to measure the mass properties of a rigid body. This unique design can measure the payload's weight, mass center location, and moments of inertia about three orthogonal axes. Furthermore, these measurements only require a single torque sensor and a single angular position sensor.
Sadot, Dan; Dorman, G; Gorshtein, Albert; Sonkin, Eduard; Vidal, Or
2015-01-26
112Gbit/sec DSP-based single channel transmission of PAM4 at 56Gbaud over 15GHz of effective analog bandwidth is experimentally demonstrated. The DSP enables use of mature 25G optoelectronics for 2-10km datacenter intra-connections, and 8Tbit/sec over 80km interconnections between data centers.
ERIC Educational Resources Information Center
Middlesex County Vocational and Technical High Schools, New Brunswick, NJ.
The Teenage Parent Center of the Single Parent Assistance, Counseling and Education Project was developed to support, guide, and direct adolescent mothers, pregnant teenagers, and teens at risk of becoming parents through successful completion of a high school diploma or school year in a vocational setting in Middlesex County, New Jersey. The…
The Sakai Spinner: A Paperclip Top
ERIC Educational Resources Information Center
Corrao, Christian T.
2014-01-01
A challenge: Can you create a stable top from a single paper clip? Several interesting solutions to this problem were provided by Takao Sakai from Japan, the requirement of each being that the center of gravity be located on the vertical y-axis at the center of the top. In the simplest configuration, we see that there exists a single angle ?…
Ross, Scott E.; Linens, Shelley W.; Wright, Cynthia J.; Arnold, Brent L.
2013-01-01
Context: Stochastic resonance stimulation (SRS) administered at an optimal intensity could maximize the effects of treatment on balance. Objective: To determine if a customized optimal SRS intensity is better than a traditional SRS protocol (applying the same percentage sensory threshold intensity for all participants) for improving double- and single-legged balance in participants with or without functional ankle instability (FAI). Design: Case-control study with an embedded crossover design. Setting: Laboratory. Patients or Other Participants: Twelve healthy participants (6 men, 6 women; age = 22 ± 2 years, height = 170 ± 7 cm, mass = 64 ± 10 kg) and 12 participants (6 men, 6 women; age = 23 ± 3 years, height = 174 ± 8 cm, mass = 69 ± 10 kg) with FAI. Intervention(s): The SRS optimal intensity level was determined by finding the intensity from 4 experimental intensities at the percentage sensory threshold (25% [SRS25], 50% [SRS50], 75% [SRS75], 90% [SRS90]) that produced the greatest improvement in resultant center-of-pressure velocity (R-COPV) over a control condition (SRS0) during double-legged balance. We examined double- and single-legged balance tests, comparing optimal SRS (SRSopt1) and SRS0 using a battery of center-of-pressure measures in the frontal and sagittal planes. Main Outcome Measure(s): Anterior-posterior (A-P) and medial-lateral (M-L) center-of-pressure velocity (COPV) and center-of-pressure excursion (COPE), R-COPV, and 95th percentile center-of-pressure area ellipse (COPA-95). Results: Data were organized into bins that represented optimal (SRSopt1), second (SRSopt2), third (SRSopt3), and fourth (SRSopt4) improvement over SRS0. The SRSopt1 enhanced R-COPV (P ≤ .05) over SRS0 and other SRS conditions (SRS0 = 0.94 ± 0.32 cm/s, SRSopt1 = 0.80 ± 0.19 cm/s, SRSopt2 = 0.88 ± 0.24 cm/s, SRSopt3 = 0.94 ± 0.25 cm/s, SRSopt4 = 1.00 ± 0.28 cm/s). However, SRS did not improve R-COPV over SRS0 when data were categorized by sensory threshold. Furthermore, SRSopt1 improved double-legged balance over SRS0 from 11% to 25% in all participants for the center-of-pressure frontal- and sagittal-plane assessments (P ≤ .05). The SRSopt1 also improved single-legged balance over SRS0 from 10% to 17% in participants with FAI for the center-of-pressure frontal- and sagittal-plane assessments (P ≤ .05). The SRSopt1 did not improve single-legged balance in participants with stable ankles. Conclusions: The SRSopt1 improved double-legged balance and transfers to enhancing single-legged balance deficits associated with FAI. PMID:23724774
Myer, Gregory D; Bates, Nathaniel A; DiCesare, Christopher A; Barber Foss, Kim D; Thomas, Staci M; Wordeman, Samuel C; Sugimoto, Dai; Roewer, Benjamin D; Medina McKeon, Jennifer M; Di Stasi, Stephanie L; Noehren, Brian W; McNally, Michael; Ford, Kevin R; Kiefer, Adam W; Hewett, Timothy E
2015-05-01
Due to the limitations of single-center studies in achieving appropriate sampling with relatively rare disorders, multicenter collaborations have been proposed to achieve desired sampling levels. However, documented reliability of biomechanical data is necessary for multicenter injury-prevention studies and is currently unavailable. To measure the reliability of 3-dimensional (3D) biomechanical waveforms from kinetic and kinematic variables during a single-leg landing (SLL) performed at 3 separate testing facilities. Multicenter reliability study. 3 laboratories. 25 female junior varsity and varsity high school volleyball players who visited each facility over a 1-mo period. Subjects were instrumented with 43 reflective markers to record 3D motion as they performed SLLs. During the SLL the athlete balanced on 1 leg, dropped down off of a 31-cm-high box, and landed on the same leg. Kinematic and kinetic data from both legs were processed from 2 trials across the 3 laboratories. Coefficients of multiple correlations (CMC) were used to statistically compare each joint angle and moment waveform for the first 500 ms of landing. Average CMC for lower-extremity sagittal-plane motion was excellent between laboratories (hip .98, knee .95, ankle .99). Average CMC for lower-extremity frontal-plane motion was also excellent between laboratories (hip .98, knee .80, ankle .93). Kinetic waveforms were repeatable in each plane of rotation (3-center mean CMC ≥.71), while knee sagittal-plane moments were the most consistent measure across sites (3-center mean CMC ≥.94). CMC waveform comparisons were similar relative to the joint measured to previously published reports of between-sessions reliability of sagittal- and frontal-plane biomechanics performed at a single institution. Continued research is needed to further standardize technology and methods to help ensure that highly reliable results can be achieved with multicenter biomechanical screening models.
NASA Astrophysics Data System (ADS)
Rong, Youying; Ma, Jianhui; Chen, Lingxiao; Liu, Yan; Siyushev, Petr; Wu, Botao; Pan, Haifeng; Jelezko, Fedor; Wu, E.; Zeng, Heping
2018-05-01
We report a method with high time resolution to measure the excited-state lifetime of silicon vacancy centers in bulk diamond avoiding timing jitter from the single-photon detectors. Frequency upconversion of the fluorescence emitted from silicon vacancy centers was achieved from 738 nm to 436 nm via sum frequency generation with a short pump pulse. The excited-state lifetime can be obtained by measuring the intensity of upconverted light while the pump delay changes. As a probe, a pump laser with pulse duration of 11 ps provided a high temporal resolution of the measurement. The lifetime extracted from the pump–probe curve was 0.755 ns, which was comparable to the timing jitter of the single-photon detectors.
NASA Astrophysics Data System (ADS)
Bray, Kerem; Previdi, Rodolfo; Gibson, Brant C.; Shimoni, Olga; Aharonovich, Igor
2015-03-01
Fluorescent nanodiamonds are attracting major attention in the field of bio-sensing and bio-labeling. In this work we demonstrate a robust approach to achieve an encapsulation of individual nanodiamonds with phenol-ionic complexes that enhance the photoluminescence from single nitrogen vacancy (NV) centers. We show that single NV centres in the coated nanodiamonds also exhibit shorter lifetimes, opening another channel for high resolution sensing. We propose that the nanodiamond encapsulation reduces the non-radiative decay pathways of the NV color centers. Our results provide a versatile and assessable way to enhance photoluminescence from nanodiamond defects that can be used in a variety of sensing and imaging applications.Fluorescent nanodiamonds are attracting major attention in the field of bio-sensing and bio-labeling. In this work we demonstrate a robust approach to achieve an encapsulation of individual nanodiamonds with phenol-ionic complexes that enhance the photoluminescence from single nitrogen vacancy (NV) centers. We show that single NV centres in the coated nanodiamonds also exhibit shorter lifetimes, opening another channel for high resolution sensing. We propose that the nanodiamond encapsulation reduces the non-radiative decay pathways of the NV color centers. Our results provide a versatile and assessable way to enhance photoluminescence from nanodiamond defects that can be used in a variety of sensing and imaging applications. Electronic supplementary information (ESI) available. See DOI: 10.1039/c4nr07510b
Head bobbing and the body movement of little egrets ( Egretta garzetta) during walking.
Fujita, Masaki
2003-01-01
Although previous studies have indicated that head bobbing of birds is an optokinetic movement, head bobbing can also be controlled by some biomechanical constraints when it occurs during walking. In the present study, the head bobbing, center of gravity, and body movements of little egrets (Egretta garzetta) during walking were examined by determination of the position of the center of gravity using carcasses and by motion analysis of video films of wild egrets during walking. The results showed that the hold phase occurs while the center of gravity is over the supporting foot during the single support phase. In addition, the peak speed of neck extension was coincident with the peak speed of the center of gravity. These movements are similar to those of pigeons, and suggest the presence of biomechanical constraints on the pattern of head bobbing and body movements during walking.
Color-Center Production and Formation in Electron-Irradiated Magnesium Aluminate Spinel and Ceria
Costantini, Jean-Marc; Lelong, Gerald; Guillaumet, Maxime; ...
2016-06-20
Single crystals of magnesium aluminate spinel (MgAl2O4) with (100) or (110) orientations and cerium dioxide or ceria (CeO2) were irradiated by 1.0-MeV and 2.5-MeV electrons in a high fluence range. Point-defect production was studied by off-line UV-visible optical spectroscopy after irradiation. For spinel, regardless of both crystal orientation and electron energy, two characteristic broad bands centered at photon energies of 5.4 eV and 4.9 eV were assigned to F and F+ centers (neutral and singly-ionized oxygen vacancies), respectively, on the basis of available literature data. No clear differences in colour-centre formation were observed for the two crystal orientations. Using calculationsmore » of displacement cross sections by elastic collisions, these results are consistent with a very large threshold displacement energy (200 eV) for oxygen atoms at RT. A third very broad band centered at 3.7 eV might be attributed either to an oxygen hole center (V-type center) or an F2 dimer center (oxygen di-vacancy). The onset of recovery of these color centers took place at 200°C with almost full bleaching at 600°C. Activation energies (~0.3-0.4 eV) for defect recovery were deduced from the isochronal annealing data by using a first-order kinetics analysis. For ceria, a sub band-gap absorption feature peaked at ~3.1 eV was recorded for 2.5-MeV electron irradiation only. Assuming a ballistic process, we suggest that the latter defect might result from cerium atom displacement on the basis of computed cross sections.« less
Schwartz, J.; Aloni, S.; Ogletree, D. F.; ...
2012-04-20
Exposure to beams of low-energy electrons (2-30 keV) in a scanning electron microscope locally induces formation of NV-centers without thermal annealing in diamonds that have been implanted with nitrogen ions. In this study, we find that non-thermal, electron-beam-induced NV-formation is about four times less efficient than thermal annealing. But NV-center formation in a consecutive thermal annealing step (800°C) following exposure to low-energy electrons increases by a factor of up to 1.8 compared to thermal annealing alone. Finally, these observations point to reconstruction of nitrogen-vacancy complexes induced by electronic excitations from low-energy electrons as an NV-center formation mechanism and identify localmore » electronic excitations as a means for spatially controlled room-temperature NV-center formation.« less
EPR investigation of the trivalent chromium complexes in SrTiO3
NASA Astrophysics Data System (ADS)
Azamat, D. V.; Dejneka, A.; Lančok, J.; Jastrabik, L.; Trepakov, V. A.; Bryknar, Z.; Neverova, E. V.; Badalyan, A. G.
2014-02-01
The trivalent chromium centers were investigated by means of electron paramagnetic resonance (EPR) in SrTiO3 single crystals grown using the Verneuil technique. It was shown that the charge compensation of the Cr3+-VO dominant centers in octahedral environment is due to the remote oxygen vacancy located on the axial axis of the center. In order to provide insight into spin-phonon relaxation processes the studies of axial distortion of Cr3+-VO centers have been performed as function of temperature. The analysis of the trigonal Cr3+ centers found in SrTiO3 indicates the presence of the nearest-neighbor strontium vacancy. The next-nearest-neighbor exchange-coupled pairs of Cr3+ in SrTiO3 has been analyzed from the angular variation of the total electron spin of S=2 resonance lines.
Dislocation Multiplication by Single Cross Slip for FCC at Submicron Scales
NASA Astrophysics Data System (ADS)
Cui, Yi-Nan; Liu, Zhan-Li; Zhuang, Zhuo
2013-04-01
The operation mechanism of single cross slip multiplication (SCSM) is investigated by studying the response of one dislocation loop expanding in face-centered-cubic (FCC) single crystal using three-dimensional discrete dislocation dynamic (3D-DDD) simulation. The results show that SCSM can trigger highly correlated dislocation generation in a short time, which may shed some light on understanding the large strain burst observed experimentally. Furthermore, we find that there is a critical stress and material size for the operation of SCSM, which agrees with that required to trigger large strain burst in the compression tests of FCC micropillars.
Solano, Jesús Ramírez; Baños, Alejandro Trejo; Durán, Álvaro Miranda; Quiroz, Eliel Carvajal; Irisson, Miguel Cruz
2017-09-26
In the development of quantum computing and communications, improvements in materials capable of single photon emission are of great importance. Advances in single photon emission have been achieved experimentally by introducing nitrogen-vacancy (N-V) centers on diamond nanostructures. However, theoretical modeling of the anisotropic effects on the electronic properties of these materials is almost nonexistent. In this study, the electronic band structure and density of states of diamond nanowires with N-V defects were analyzed through first principles approach using the density functional theory and the supercell scheme. The nanowires were modeled on two growth directions [001] and [111]. All surface dangling bonds were passivated with hydrogen (H) atoms. The results show that the N-V introduces multiple trap states within the energy band gap of the diamond nanowire. The energy difference between these states is influenced by the growth direction of the nanowires, which could contribute to the emission of photons with different wavelengths. The presence of these trap states could reduce the recombination rate between the conduction and the valence band, thus favoring the single photon emission. Graphical abstract Diamond nanowires with nitrogen-vacancy centerᅟ.
Impaired health-related quality of life in acute myeloid leukemia survivors: a single-center study.
Leunis, Annemieke; Redekop, William K; Uyl-de Groot, Carin A; Löwenberg, Bob
2014-09-01
The purpose of this study was to assess the impact of acute myeloid leukemia (AML) and its treatment on health-related quality of life (HRQOL) by comparing the HRQOL of AML survivors with the HRQOL in the general population. Two HRQOL questionnaires (EQ-5D and QLQ-C30) were sent to patients diagnosed with AML between 1999 and 2011 at a single academic hospital and still alive in 2012. HRQOL in AML survivors was compared with general population reference values. Multivariate analysis was used to identify factors associated with HRQOL in AML survivors. Questionnaires were returned by 92 of the 103 patients (89%). AML survivors reported significantly worse functioning, more fatigue, pain, dyspnea, appetite loss, and financial difficulties and lower EQ-VAS scores than the general population (P < 0.05). Impaired HRQOL in AML survivors was mainly found in survivors without a paid job. Other factors associated with a poor HRQOL were allogeneic hematopoietic stem cell transplantation and the absence of social support. This single-center study showed that the HRQOL in AML survivors is worse than the HRQOL in the general population. HRQOL in these patients can be improved by adequately treating and preventing fatigue, pain, dyspnea, and appetite loss. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
NASA Astrophysics Data System (ADS)
Kim, Moonyong; Chen, Daniel; Abbott, Malcolm; Nampalli, Nitin; Wenham, Stuart; Stefani, Bruno; Hallam, Brett
2018-04-01
We explore the influence of interstitial iron (Fei) on lifetime spectroscopy of boron-oxygen (B-O) related degradation in p-type Czochralski silicon. Theoretical and experimental evidence presented in this study indicate that iron-boron pair (Fe-B) related reactions could have influenced several key experimental results used to derive theories on the fundamental properties of the B-O defect. Firstly, the presence of Fei can account for higher apparent capture cross-section ratios (k) of approximately 100 observed in previous studies during early stages of B-O related degradation. Secondly, the association of Fe-B pairs can explain the initial stage of a two-stage recovery of carrier lifetime with dark annealing after partial degradation. Thirdly, Fei can result in high apparent k values after the permanent deactivation of B-O defects. Subsequently, we show that a single k value can describe the recombination properties associated with B-O defects throughout degradation, that the recovery during dark annealing occurs with a single-stage, and both the fast- and slow-stage B-O related degradation can be permanently deactivated during illuminated annealing. Accounting for the recombination activity of Fei provides further evidence that the B-O defect is a single defect, rather than two separate defects normally attributed to fast-forming recombination centers and slow-forming recombination centers. Implications of this finding for the nature of the B-O defect are also discussed.
Prabhakar, Attiguppe R; Yavagal, Chandrashekar; Dixit, Kratika; Naik, Saraswathi V
2016-01-01
Primary root canals are considered to be most challenging due to their complex anatomy. "Wave one" and "one shape" are single-file systems with reciprocating and rotary motion respectively. The aim of this study was to evaluate and compare dentin thickness, centering ability, canal transportation, and instrumentation time of wave one and one shape files in primary root canals using a cone beam computed tomographic (CBCT) analysis. This is an experimental, in vitro study comparing the two groups. A total of 24 extracted human primary teeth with minimum 7 mm root length were included in the study. Cone beam computed tomographic images were taken before and after the instrumentation for each group. Dentin thickness, centering ability, canal transportation, and instrumentation times were evaluated for each group. A significant difference was found in instrumentation time and canal transportation measures between the two groups. Wave one showed less canal transportation as compared with one shape, and the mean instrumentation time of wave one was significantly less than one shape. Reciprocating single-file systems was found to be faster with much less procedural errors and can hence be recommended for shaping the root canals of primary teeth. How to cite this article: Prabhakar AR, Yavagal C, Dixit K, Naik SV. Reciprocating vs Rotary Instrumentation in Pediatric Endodontics: Cone Beam Computed Tomographic Analysis of Deciduous Root Canals using Two Single-File Systems. Int J Clin Pediatr Dent 2016;9(1):45-49.
Kim, Nam Hoon; Hwang, Wooseup; Baek, Kangkyun; Rohman, Md Rumum; Kim, Jeehong; Kim, Hyun Woo; Mun, Jungho; Lee, So Young; Yun, Gyeongwon; Murray, James; Ha, Ji Won; Rho, Junsuk; Moskovits, Martin; Kim, Kimoon
2018-04-04
Single-molecule surface-enhanced Raman spectroscopy (SERS) offers new opportunities for exploring the complex chemical and biological processes that cannot be easily probed using ensemble techniques. However, the ability to place the single molecule of interest reliably within a hot spot, to enable its analysis at the single-molecule level, remains challenging. Here we describe a novel strategy for locating and securing a single target analyte in a SERS hot spot at a plasmonic nanojunction. The "smart" hot spot was generated by employing a thiol-functionalized cucurbit[6]uril (CB[6]) as a molecular spacer linking a silver nanoparticle to a metal substrate. This approach also permits one to study molecules chemically reluctant to enter the hot spot, by conjugating them to a moiety, such as spermine, that has a high affinity for CB[6]. The hot spot can accommodate at most a few, and often only a single, analyte molecule. Bianalyte experiments revealed that one can reproducibly treat the SERS substrate such that 96% of the hot spots contain a single analyte molecule. Furthermore, by utilizing a series of molecules each consisting of spermine bound to perylene bisimide, a bright SERS molecule, with polymethylene linkers of varying lengths, the SERS intensity as a function of distance from the center of the hot spot could be measured. The SERS enhancement was found to decrease as 1 over the square of the distance from the center of the hot spot, and the single-molecule SERS cross sections were found to increase with AgNP diameter.
Wang, Rui-Xia; Cai, Kang; Yin, Zhang-Qi; Long, Gui-Lu
2017-11-27
In a diamond, the mechanical vibration-induced strain can lead to interaction between the mechanical mode and the nitrogen-vacancy (NV) centers. In this work, we propose to utilize the strain-induced coupling for the quantum non-demolition (QND) single phonon measurement and memory in a diamond. The single phonon in a diamond mechanical resonator can be perfectly absorbed and emitted by the NV centers ensemble (NVE) with adiabatically tuning the microwave driving. An optical laser drives the NVE to the excited states, which have much larger coupling strength to the mechanical mode. By adiabatically eliminating the excited states under large detuning limit, the effective coupling between the mechanical mode and the NVE can be used for QND measurement of the single phonon state. Under realistic experimental conditions, we numerically simulate the scheme. It is found that the fidelity of the absorbing and emitting process can reach a much high value. The overlap between the input and the output phonon shapes can reach 98.57%.
Li, Fuzhong; Harmer, Peter
2014-05-26
Falls are the leading cause of injury death in older adults and present a significant public health problem and a major burden to healthcare. Although there is sufficient evidence from randomized controlled trials to indicate that exercise can prevent falls in older people, few effective, evidence-based fall prevention programs exist in community practice. Thus, there is a pressing need to translate and disseminate evidence-based exercise programs to community providers that serve older adults at increased risk of falling. The current study addresses this public health need by disseminating the evidence-based Tai Ji Quan: Moving for Better Balance (TJQMBB) program through community senior centers. The study uses a single-group design in which the TJQMBB program is being delivered to community-dwelling older adults through collaboration with senior centers in selected counties in Oregon, USA, for 48 weeks, followed by a 24-week post-intervention follow-up. Study process and outcome measures will be evaluated in accordance with the components of the RE-AIM framework that focus on Reach, Effectiveness, Adoption, Implementation and Maintenance. This study will determine whether the evidence-based TJQMBB fall prevention program can be disseminated through a broad spectrum of community-based senior centers that often cater to low-income, underserved community-dwelling older adults at risk of falling. If shown to be both practically implementable and sustainable, the TJQMBB program will provide an effective, potentially low-cost, easy-to-implement intervention that could be used by public health practitioners and community-based organizations to address the problem of falls among older adults. ClinicalTrials.gov Identifier: NCT01854931.
Secondary Writing Centers: Benefits of College and Secondary Collaboration.
ERIC Educational Resources Information Center
Brinkley, Ellen H.
Based on college writing center models, a number of high schools are deciding to establish writing centers, some of them in anticipation of competency tests in composition. Staffing can be the single most significant and expensive factor for secondary schools wanting to provide writing centers. Among the options for dealing with the staffing…
NASA Astrophysics Data System (ADS)
Rajchl, Martin; Abhari, Kamyar; Stirrat, John; Ukwatta, Eranga; Cantor, Diego; Li, Feng P.; Peters, Terry M.; White, James A.
2014-03-01
Multi-center trials provide the unique ability to investigate novel techniques across a range of geographical sites with sufficient statistical power, the inclusion of multiple operators determining feasibility under a wider array of clinical environments and work-flows. For this purpose, we introduce a new means of distributing pre-procedural cardiac models for image-guided interventions across a large scale multi-center trial. In this method, a single core facility is responsible for image processing, employing a novel web-based interface for model visualization and distribution. The requirements for such an interface, being WebGL-based, are minimal and well within the realms of accessibility for participating centers. We then demonstrate the accuracy of our approach using a single-center pacemaker lead implantation trial with generic planning models.
Woolacott, Nerys; Corbett, Mark; Jones-Diette, Julie; Hodgson, Robert
2017-10-01
Regulatory authorities are approving innovative therapies with limited evidence. Although this level of data is sufficient for the regulator to establish an acceptable risk-benefit balance, it is problematic for downstream health technology assessment, where assessment of cost-effectiveness requires reliable estimates of effectiveness relative to existing clinical practice. Some key issues associated with a limited evidence base include using data, from nonrandomized studies, from small single-arm trials, or from single-center trials; and using surrogate end points. We examined these methodological challenges through a pragmatic review of the available literature. Methods to adjust nonrandomized studies for confounding are imperfect. The relative treatment effect generated from single-arm trials is uncertain and may be optimistic. Single-center trial results may not be generalizable. Surrogate end points, on average, overestimate treatment effects. Current methods for analyzing such data are limited, and effectiveness claims based on these suboptimal forms of evidence are likely to be subject to significant uncertainty. Assessments of cost-effectiveness, based on the modeling of such data, are likely to be subject to considerable uncertainty. This uncertainty must not be underestimated by decision makers: methods for its quantification are required and schemes to protect payers from the cost of uncertainty should be implemented. Crown Copyright © 2017. Published by Elsevier Inc. All rights reserved.
An overview of the NASA rotary engine research program
NASA Technical Reports Server (NTRS)
Meng, P. R.; Hady, W. F.
1984-01-01
A brief overview and technical highlights of the research efforts and studies on rotary engines over the last several years at the NASA Lewis Research Center are presented. The test results obtained from turbocharged rotary engines and preliminary results from a high performance single rotor engine were discussed. Combustion modeling studies of the rotary engine and the use of a Laser Doppler Velocimeter to confirm the studies were examined. An in-house program in which a turbocharged rotary engine was installed in a Cessna Skymaster for ground test studies was reviewed. Details are presented on single rotor stratified charge rotary engine research efforts, both in-house and on contract.
X-ray-induced fluorescent centers formation in zinc- phosphate glasses doped with Ag and Cu ions
NASA Astrophysics Data System (ADS)
Klyukin, D. A.; Pshenova, A. S.; Sidorov, A. I.; Stolyarchuk, M. V.
2016-08-01
Fluorescent properties of silver and copper doped zinc-phosphate glasses were studied. By X-ray irradiation of silver and copper co-doped glasses we could create and identify new emission centers which do not exist in single-doped samples. Doping of the glass with both silver and copper ions leads to the increase of quantum yield by 2.7 times. The study was complemented by quantum chemical calculations using the time-dependent density functional theory. It was shown that fluorescence may be attributed to the formation of mixed Ag-Cu molecular clusters.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Abraham, John Bishoy Sam; Pacheco, Jose L.; Aguirre, Brandon Adrian
2016-08-09
We demonstrate low energy single ion detection using a co-planar detector fabricated on a diamond substrate and characterized by ion beam induced charge collection. Histograms are taken with low fluence ion pulses illustrating quantized ion detection down to a single ion with a signal-to-noise ratio of approximately 10. We anticipate that this detection technique can serve as a basis to optimize the yield of single color centers in diamond. In conclusion, the ability to count ions into a diamond substrate is expected to reduce the uncertainty in the yield of color center formation by removing Poisson statistics from the implantationmore » process.« less
Validation of Caregiver-Centered Delirium Detection Tools: A Systematic Review.
Rosgen, Brianna; Krewulak, Karla; Demiantschuk, Danielle; Ely, E Wesley; Davidson, Judy E; Stelfox, Henry T; Fiest, Kirsten M
2018-04-18
To summarize the validity of caregiver-centered delirium detection tools in hospitalized adults and assess associated patient and caregiver outcomes. Systematic review. We searched MEDLINE, EMBASE, PsycINFO, CINAHL, and Scopus from inception to May 15, 2017. Hospitalized adults. Caregiver-centered delirium detection tools. We drafted a protocol from the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Two reviewers independently completed abstract and full-text review, data extraction, and quality assessment. We summarized findings using descriptive statistics including mean, median, standard deviation, range, frequencies (percentages), and Cohen's kappa. Studies that reported on the validity of caregiver-centered delirium detection tools or associated patient and caregiver outcomes and were cohort or cross-sectional in design were included. We reviewed 6,056 titles and abstracts, included 6 articles, and identified 6 caregiver-centered tools. All tools were designed to be administered in several minutes or less and had 11 items or fewer. Three tools were caregiver administered (completed independently by caregivers): Family Confusion Assessment Method (FAM-CAM), Informant Assessment of Geriatric Delirium (I-AGeD), and Sour Seven. Three tools were caregiver informed (administered by a healthcare professional using caregiver input): Single Question in Delirium (SQiD), Single Screening Question Delirium (SSQ-Delirium), and Stressful Caregiving Response to Experiences of Dying. Caregiver-administered tools had better psychometric properties (FAM-CAM sensitivity 75%, 95% confidence interval (CI)=35-95%, specificity 91%, 95% CI=74-97%; Sour Seven positive predictive value 89.5%, negative predictive value 90%) than caregiver-informed tools (SQiD: sensitivity 80%, 95% CI=28.4-99.5%; specificity 71%, 95% CI=41.9-91.6%; SSQ-Delirium sensitivity 79.6%, specificity 56.1%). Delirium detection is essential for appropriate delirium management. Caregiver-centered delirium detection tools show promise in improving delirium detection and associated patient and caregiver outcomes. Comparative studies using larger sample sizes and multiple centers are required to determine validity and reliability characteristics. © 2018, Copyright the Authors Journal compilation © 2018, The American Geriatrics Society.
Prabhakar, Attiguppe R; Yavagal, Chandrashekar; Naik, Saraswathi V
2016-01-01
ABSTRACT Background: Primary root canals are considered to be most challenging due to their complex anatomy. "Wave one" and "one shape" are single-file systems with reciprocating and rotary motion respectively. The aim of this study was to evaluate and compare dentin thickness, centering ability, canal transportation, and instrumentation time of wave one and one shape files in primary root canals using a cone beam computed tomographic (CBCT) analysis. Study design: This is an experimental, in vitro study comparing the two groups. Materials and methods: A total of 24 extracted human primary teeth with minimum 7 mm root length were included in the study. Cone beam computed tomographic images were taken before and after the instrumentation for each group. Dentin thickness, centering ability, canal transportation, and instrumentation times were evaluated for each group. Results: A significant difference was found in instrumentation time and canal transportation measures between the two groups. Wave one showed less canal transportation as compared with one shape, and the mean instrumentation time of wave one was significantly less than one shape. Conclusion: Reciprocating single-file systems was found to be faster with much less procedural errors and can hence be recommended for shaping the root canals of primary teeth. How to cite this article: Prabhakar AR, Yavagal C, Dixit K, Naik SV. Reciprocating vs Rotary Instrumentation in Pediatric Endodontics: Cone Beam Computed Tomographic Analysis of Deciduous Root Canals using Two Single-File Systems. Int J Clin Pediatr Dent 2016;9(1):45-49. PMID:27274155
Laundry pack exposures in children 0-5 years evaluated at a single pediatric institution.
Yin, Shan; Behrman, Alysha; Colvin, Jonathan
2015-05-01
Case reports and poison center series have highlighted increased safety concerns with laundry packs, especially when compared to traditional laundry detergents. The purpose of this study was to examine the clinical experience with laundry pack exposures at a single institution. A retrospective chart review was performed for exposures to laundry packs seen at a single tertiary care children's hospital medical center. Cases were identified by searching the poison center database for exposures to laundry products from March 2012 to October 2013 in children <5 years old. Medical records were reviewed for all identified cases. Data collected included demographics, treatments, laboratory and radiology data, disposition, and length of stay in the emergency department (ED). Forty cases were included. Thirty-two were ingestions and eight were ocular exposures. Nine children were admitted, two of which were admitted to a critical care unit. Seven other children were discharged after 1-night admissions; none received any treatments after initial ED treatment. Of these, four children were admitted for the possibility of central nervous system (CNS) depression, but none showed any progression. Twenty-nine children with ingestions were discharged directly from the ED. No children had progression of CNS symptoms. Children discharged from the ED were observed a mean of 189 min. Cases of laundry pack exposures seen at our institution were similar to cases described by US poison centers. No child had progression of CNS depression suggesting that prolonged observation is not necessary if the child does not have CNS depression at presentation. Copyright © 2015 Elsevier Inc. All rights reserved.
Liu, Winnie; Zahr, Roula Shraiky; McCartney, Shirley; Cetas, Justin S; Dogan, Aclan; Fleseriu, Maria
2018-06-23
Lactotroph adenomas (LA) are the most frequently encountered pituitary tumors. Although more frequently observed in women, LAs in men were recently included in a more aggressive category regardless of histological grading, by the WHO. We aimed to perform a rigorous retrospective review of a single center's pre-operative evaluation, patient characteristics and outcomes of male LAs patients requiring pituitary surgery. A retrospective review, over 11 years, of patients who underwent resection of a pituitary adenoma at a single center was conducted. Predictors of persistent disease in male LAs patients along with a comparison to predictors of silent corticotroph adenomas (SCAs) patients who also underwent surgery at the center was also conducted. Thirty-one male patients with LAs were identified. When compared to SCAs patients, LAs male patients were younger (41 vs. 50 years of age, p = 0.01). Men with LAs had more invasive tumors (75% vs. 44.7% p = 0.02). More LAs in men had residual tumor after surgery than patients with SCA (92.6% vs. 42.1%, p < 0.001). Male patients with LAs and patients with SCA had similar rates of requiring additional surgery (28.9% vs. 24.1%, p = NS) and radiation therapy (18.4% vs. 19.4%, p = NS). High rates of DA resistance, invasive tumors and postoperative residual disease in male patients with LA who required surgery are shown. Surgery improved optic chiasm compression, PRL level and central hypogonadism but, not surprisingly, failed to normalize other pituitary hormones and/or eliminate need for DA therapy.
Single, transcervical insemination using frozen-thawed semen in the Greyhound: a case series study.
Pretzer, S D; Lillich, R K; Althouse, G C
2006-04-01
Transcervical insemination (TCI) has generated recent interest as an assisted reproductive technique in the dog. A case series study was performed to determine if TCI using frozen-thawed semen was a viable technique to offer in a general veterinary practice setting. Over a period exceeding 28 months, 137 Greyhound bitches were presented for assisted breeding. A single, timed insemination using a rigid cystoscope to aid in transcervical deposition of a frozen-thawed semen dose was given within 72 h after the behaviorally estrual bitch had a > 4 ng/mL serum progesterone concentration and estrus-categorized vaginal cytology. Litter size, pregnancy and whelping rate were collected; their association to semen center and stud dog were quantified. Of the 137 bitches, 117 were bred for one cycle and 20 were bred for two or more cycles, giving a total of 161 single, timed inseminations. Pregnancy rate was 89.4%, with 141 (87.5%) whelping. Litter size was 6.9+/-2.7 (mean+/-S.D.) pups. Semen center (P=0.84) and stud (P=0.79) had no effect on pregnancy. These results were quite favorable when compared to prior TCI studies, and are possibly due to the use of a single breed (i.e., Greyhound) with good fertility. This study supported the application of TCI, in Greyhounds, as a successful and viable service to offer in private practice. Additionally, these results have value in their use for benchmarking future breed-specific and TCI research. Serendipitously, the apparent fecundity results obtained in this observational study suggests a possible greater appreciation be given to breed composition and choice in assisted reproductive technique studies.
Summary of compliant and multi-arm control at NASA. Langley Research Center
NASA Technical Reports Server (NTRS)
Harrison, Fenton W.
1992-01-01
The topics are presented in viewgraph form and include the: single arm system, single arm axis system, single arm control systems, single arm hand controller axis system, single arm position axis system, single arm vision axis system, single arm force axis system, multi-arm system, multi-arm axis system, and the dual arm hand control axis system with control signals.
Burkhardt, Dwight A.; Bartoletti, Theodore M.; Thoreson, Wallace B.
2012-01-01
Receptive field organization of cone-driven bipolar cells was investigated by intracellular recording in the intact light-adapted retina of the tiger salamander (Ambystoma tigrinum). Centered spots and concentric annuli of optimum dimensions were used to selectively stimulate the receptive field center and surround with sinusoidal modulations of contrast at 3 Hz. At low contrasts, responses of both the center and surround of both ON and OFF bipolar cells were linear, showing high gain and thus contrast enhancement relative to cones. The contrast/response curves for the fundamental response, measured by a Fast Fourier Transform, reached half maximum amplitude quickly at 13% contrast followed by saturation at high contrasts. The variation of the normalized amplitude of the center and surround responses was remarkably similar, showing linear regression over the entire response range with very high correlations, r2 = 0.97 for both ON and OFF cells. The contrast/response curves of both center and surround for both ON and OFF cells were well fit (r2 = 0.98) by an equation for single-site binding. In about half the cells studied, the nonlinear waveforms of center and surround could be brought into coincidence by scaling and shifting the surround response in time. This implies that a nonlinearity, common to both center and surround, occurs after polarity inversion at the cone feedback synapse. Evidence from paired whole-cell recordings between single cones and OFF bipolar cells suggests that substantial nonlinearity is not due to transmission at the cone synapse but instead arises from intrinsic bipolar cell and network mechanisms. When sinusoidal contrast modulations were applied to the center and surround simultaneously, clear additivity was observed for small responses in both ON and OFF cells, whereas the interaction was strikingly nonadditive for large responses. The contribution of the surround was then greatly reduced, suggesting attenuation at the cone feedback synapse. PMID:21439110
NASA Astrophysics Data System (ADS)
Bolshedvorskii, S. V.; Vorobyov, V. V.; Soshenko, V. V.; Zeleneev, A.; Sorokin, V. N.; Smolyaninov, A. N.; Akimov, A. V.
2018-02-01
Quickly developing application of nitrogen-vacancy color centers in diamond sets demands on cheap and high optical and spin properties nanodiamonds. Among other types, detonation nanodiamonds are easiest for production but often show no NV color centers inside. In this work we show, that aggregates of detonation nanodiamonds could be as good, or even better in terms of brightness and spin properties, than more expensive single crystal nanodiamonds. This way aggregates of detonation nanodiamonds could efficiently serve as cheap and bright source of single photon radiation or sensitive element of biocompatible sensor.
Superresolution Microscopy of Single Rare-Earth Emitters in YAG and H 3 Centers in Diamond
NASA Astrophysics Data System (ADS)
Kolesov, R.; Lasse, S.; Rothfuchs, C.; Wieck, A. D.; Xia, K.; Kornher, T.; Wrachtrup, J.
2018-01-01
We demonstrate superresolution imaging of single rare-earth emitting centers, namely, trivalent cerium, in yttrium aluminum garnet crystals by means of stimulated emission depletion (STED) microscopy. The achieved all-optical resolution is ≈50 nm . Similar results were obtained on H 3 color centers in diamond. In both cases, STED resolution is improving slower than the conventional inverse square-root dependence on the depletion beam intensity. In the proposed model of this effect, the anomalous behavior is caused by excited state absorption and the interaction of the emitter with nonfluorescing crystal defects in its local surrounding.
Single crystal and optical ceramic multicomponent garnet scintillators: A comparative study
NASA Astrophysics Data System (ADS)
Wu, Yuntao; Luo, Zhaohua; Jiang, Haochuan; Meng, Fang; Koschan, Merry; Melcher, Charles L.
2015-04-01
Multicomponent garnet materials can be made in optical ceramic as well as single crystal form due to their cubic crystal structure. In this work, high-quality Gd3Ga3Al2O12:0.2 at% Ce (GGAG:Ce) single crystal and (Gd,Lu)3Ga3Al2O12:1 at% Ce (GLuGAG:Ce) optical ceramics were fabricated by the Czochralski method and a combination of hot isostatic pressing (HIPing) and annealing treatment, respectively. Under optical and X-ray excitation, the GLuGAG:Ce optical ceramic exhibits a broad Ce3+ transition emission centered at 550 nm, while the emission peak of the GGAG:Ce single crystal is centered at 540 nm. A self-absorption effect in GLuGAG:Ce optical ceramic results in this red-shift of the Ce3+ emission peak compared to that in the GGAG:Ce single crystal. The light yield under 662 keV γ-ray excitation was 45,000±2500 photons/MeV and 48,200±2410 photons/MeV for the GGAG:Ce single crystal and GLuGAG:Ce optical ceramic, respectively. An energy resolution of 7.1% for 662 keV γ-rays was achieved in the GLuGAG:Ce optical ceramic with a Hamamatsu R6231 PMT, which is superior to the value of 7.6% for a GGAG:Ce single crystal. Scintillation decay time measurements under 137Cs irradiation show two exponential decay components of 58 ns (47%) and 504 ns (53%) for the GGAG:Ce single crystal, and 84 ns (76%) and 148 ns (24%) for the GLuGAG:Ce optical ceramic. The afterglow level after X-ray cutoff in the GLuGAG:Ce optical ceramic is at least one order of magnitude lower than in the GGAG:Ce single crystal.
Scientist, Single Cell Analysis Facility | Center for Cancer Research
The Cancer Research Technology Program (CRTP) develops and implements emerging technology, cancer biology expertise and research capabilities to accomplish NCI research objectives. The CRTP is an outward-facing, multi-disciplinary hub purposed to enable the external cancer research community and provides dedicated support to NCI’s intramural Center for Cancer Research (CCR). The dedicated units provide electron microscopy, protein characterization, protein expression, optical microscopy and nextGen sequencing. These research efforts are an integral part of CCR at the Frederick National Laboratory for Cancer Research (FNLCR). CRTP scientists also work collaboratively with intramural NCI investigators to provide research technologies and expertise. KEY ROLES AND RESPONSIBILITIES We are seeking a highly motivated Scientist II to join the newly established Single Cell Analysis Facility (SCAF) of the Center for Cancer Research (CCR) at NCI. The SCAF will house state of the art single cell sequencing technologies including 10xGenomics Chromium, BD Genomics Rhapsody, DEPPArray, and other emerging single cell technologies. The Scientist: Will interact with close to 200 laboratories within the CCR to design and carry out single cell experiments for cancer research Will work on single cell isolation/preparation from various tissues and cells and related NexGen sequencing library preparation Is expected to author publications in peer reviewed scientific journals
A successful backward step correlates with hip flexion moment of supporting limb in elderly people.
Takeuchi, Yahiko
2018-01-01
The objective of this study was to determine the positional relationship between the center of mass (COM) and the center of pressure (COP) at the time of step landing, and to examine their relationship with the joint moments exerted by the supporting limb, with regard to factors of the successful backward step response. The study population comprised 8 community-dwelling elderly people that were observed to take successive multi steps after the landing of a backward stepping. Using a motion capture system and force plate, we measured the COM, COP and COM-COP deviation distance on landing during backward stepping. In addition, we measured the moment of the supporting limb joint during backward stepping. The multi-step data were compared with data from instances when only one step was taken (single-step). Variables that differed significantly between the single- and multi-step data were used as objective variables and the joint moments of the supporting limb were used as explanatory variables in single regression analyses. The COM-COP deviation in the anteroposterior was significantly larger in the single-step. A regression analysis with COM-COP deviation as the objective variable obtained a significant regression equation in the hip flexion moment (R2 = 0.74). The hip flexion moment of supporting limb was shown to be a significant explanatory variable in both the PS and SS phases for the relationship with COM-COP distance. This study found that to create an appropriate backward step response after an external disturbance (i.e. the ability to stop after 1 step), posterior braking of the COM by a hip flexion moment are important during the single-limbed standing phase.
On the role of adhesion in single-file dynamics
NASA Astrophysics Data System (ADS)
Fouad, Ahmed M.; Noel, John A.
2017-08-01
For a one-dimensional interacting system of Brownian particles with hard-core interactions (a single-file model), we study the effect of adhesion on both the collective diffusion (diffusion of the entire system with respect to its center of mass) and the tracer diffusion (diffusion of the individual tagged particles). For the case with no adhesion, all properties of these particle systems that are independent of particle labeling (symmetric in all particle coordinates and velocities) are identical to those of non-interacting particles (Lebowitz and Percus, 1967). We clarify this last fact twice. First, we derive our analytical predictions that show that the probability-density functions of single-file (ρsf) and ordinary (ρord) diffusion are identical, ρsf =ρord, predicting a nonanomalous (ordinary) behavior for the collective single-file diffusion, where the average second moment with respect to the center of mass, < x(t) 2 > , is calculated from ρ for both diffusion processes. Second, for single-file diffusion, we show, both analytically and through large-scale simulations, that < x(t) 2 > grows linearly with time, confirming the nonanomalous behavior. This nonanomalous collective behavior comes in contrast to the well-known anomalous sub-diffusion behavior of the individual tagged particles (Harris, 1965). We introduce adhesion to single-file dynamics as a second inter-particle interaction rule and, interestingly, we show that adding adhesion does reduce the magnitudes of both < x(t) 2 > and the mean square displacement per particle Δx2; but the diffusion behavior remains intact independent of adhesion in both cases. Moreover, we study the dependence of both the collective diffusion constant D and the tracer diffusion constant DT on the adhesion coefficient α.
Resonance fluorescence and quantum interference of a single NV center
NASA Astrophysics Data System (ADS)
Ma, Yong-Hong; Zhang, Xue-Feng; Wu, E.
2017-11-01
The detection of a single nitrogen-vacancy center in diamond has attracted much interest, since it is expected to lead to innovative applications in various domains of quantum information, including quantum metrology, information processing and communications, as well as in various nanotechnologies, such as biological and subdiffraction limit imaging, and tests of entanglement in quantum mechanics. We propose a novel scheme of a single NV center coupled with a multi-mode superconducting microwave cavity driven by coherent fields in squeezed vacuum. We numerically investigate the spectra in-phase quadrature and out-of-phase quadrature for different driving regimes with or without detunings. It shows that the maximum squeezing can be obtained for optimal Rabi fields. Moreover, with the same parameters, the maximum squeezing is greatly increased when the detunings are nonzero compared to the resonance case.
Shin, Sang Soo; Shin, Young-Jeon
2016-01-01
With an increasing number of studies highlighting regional social capital (SC) as a determinant of health, many studies are using multi-level analysis with merged and averaged scores of community residents' survey responses calculated from community SC data. Sufficient examination is required to validate if the merged and averaged data can represent the community. Therefore, this study analyzes the validity of the selected indicators and their applicability in multi-level analysis. Within and between analysis (WABA) was performed after creating community variables using merged and averaged data of community residents' responses from the 2013 Community Health Survey in Korea, using subjective self-rated health assessment as a dependent variable. Further analysis was performed following the model suggested by WABA result. Both E-test results (1) and WABA results (2) revealed that single-level analysis needs to be performed using qualitative SC variable with cluster mean centering. Through single-level multivariate regression analysis, qualitative SC with cluster mean centering showed positive effect on self-rated health (0.054, p<0.001), although there was no substantial difference in comparison to analysis using SC variables without cluster mean centering or multi-level analysis. As modification in qualitative SC was larger within the community than between communities, we validate that relational analysis of individual self-rated health can be performed within the group, using cluster mean centering. Other tests besides the WABA can be performed in the future to confirm the validity of using community variables and their applicability in multi-level analysis.
Joint Center Estimation Using Single-Frame Optimization: Part 1: Numerical Simulation.
Frick, Eric; Rahmatalla, Salam
2018-04-04
The biomechanical models used to refine and stabilize motion capture processes are almost invariably driven by joint center estimates, and any errors in joint center calculation carry over and can be compounded when calculating joint kinematics. Unfortunately, accurate determination of joint centers is a complex task, primarily due to measurements being contaminated by soft-tissue artifact (STA). This paper proposes a novel approach to joint center estimation implemented via sequential application of single-frame optimization (SFO). First, the method minimizes the variance of individual time frames’ joint center estimations via the developed variance minimization method to obtain accurate overall initial conditions. These initial conditions are used to stabilize an optimization-based linearization of human motion that determines a time-varying joint center estimation. In this manner, the complex and nonlinear behavior of human motion contaminated by STA can be captured as a continuous series of unique rigid-body realizations without requiring a complex analytical model to describe the behavior of STA. This article intends to offer proof of concept, and the presented method must be further developed before it can be reasonably applied to human motion. Numerical simulations were introduced to verify and substantiate the efficacy of the proposed methodology. When directly compared with a state-of-the-art inertial method, SFO reduced the error due to soft-tissue artifact in all cases by more than 45%. Instead of producing a single vector value to describe the joint center location during a motion capture trial as existing methods often do, the proposed method produced time-varying solutions that were highly correlated ( r > 0.82) with the true, time-varying joint center solution.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-23
... Denver, Kempe Center for the Prevention and Treatment of Child Abuse & Neglect AGENCY: Children's Bureau... Colorado Denver, Kempe Center for the Prevention and Treatment of Child Abuse & Neglect. SUMMARY: The..., Kempe Center for the Prevention and Treatment of Child Abuse & Neglect (Kempe Center), Denver, CO, an...
President’s Malaria Initiative
2008-11-16
the single most serious several projects on the bionomics and health hazard to Allied troops in the ecology of Anopheles in West Java, South Pacific...that augments rather than duplicates Medicine, Malaria Alert Center, in a their efforts. window exit trap study to measure the bionomics and
Modern Methods for Modeling Change in Obesity Research in Nursing.
Sereika, Susan M; Zheng, Yaguang; Hu, Lu; Burke, Lora E
2017-08-01
Persons receiving treatment for weight loss often demonstrate heterogeneity in lifestyle behaviors and health outcomes over time. Traditional repeated measures approaches focus on the estimation and testing of an average temporal pattern, ignoring the interindividual variability about the trajectory. An alternate person-centered approach, group-based trajectory modeling, can be used to identify distinct latent classes of individuals following similar trajectories of behavior or outcome change as a function of age or time and can be expanded to include time-invariant and time-dependent covariates and outcomes. Another latent class method, growth mixture modeling, builds on group-based trajectory modeling to investigate heterogeneity within the distinct trajectory classes. In this applied methodologic study, group-based trajectory modeling for analyzing changes in behaviors or outcomes is described and contrasted with growth mixture modeling. An illustration of group-based trajectory modeling is provided using calorie intake data from a single-group, single-center prospective study for weight loss in adults who are either overweight or obese.
Sekine, Ryojun; Aoki, Hiroyuki; Ito, Shinzaburo
2009-05-21
The localization and orientation of the symmetric diblock copolymer chain in a quasi-two-dimensional microphase-separated structure were studied by scanning near-field optical microscopy (SNOM). In the monolayer of poly(isobutyl methacrylate)-block-poly(octadecyl methacrylate) (PiBMA-b-PODMA), the individual PiBMA subchains were directly observed by SNOM, and the center of mass (CM) and orientational angle relative to the phase interface were examined at the single chain level. It was found that the position of the CM and the orientation of the PiBMA subchain in the lamellar structure were dependent on the curvature of the PiBMA/PODMA interface. As the interface was bent toward the objective chain, the block chain preferred the CM position closer to the domain center, and the conformation was strongly oriented perpendicularly to the domain interface. With increase of the curvature, the steric hindrance among the block chain increases, resulting in the stretched conformation.
Soluble intercellular adhesion molecule-1 and clinical outcomes in patients with acute lung injury
Eisner, Mark D.; Parsons, Polly E.; Thompson, B. Taylor; Conner, Edward R.; Matthay, Michael A.; Ware, Lorraine B.
2009-01-01
Objective To determine if levels of soluble intercellular adhesion molecule-1 (sICAM-1), a marker of alveolar epithelial and endothelial injury, differ in patients with hydrostatic pulmonary edema and acute lung injury (ALI) and are associated with clinical outcomes in patients with ALI. Design, setting, and participants Measurement of sICAM-1 levels in (1) plasma and edema fluid from 67 patients with either hydrostatic pulmonary edema or ALI enrolled in an observational, prospective single center study, and (2) in plasma from 778 patients with ALI enrolled in a large multi-center randomized controlled trial of ventilator strategy. Results In the single-center study, levels of sICAM-1 were significantly higher in both edema fluid and plasma (median 938 and 545 ng/ml, respectively) from ALI patients compared to hydrostatic edema patients (median 384 and 177 ng/ml, P < 0.03 for both comparisons). In the multi-center study, higher plasma sICAM-1 levels were associated with poor clinical outcomes in both unadjusted and multivariable models. Subjects with ALI whose plasma sICAM-1 levels increased over the first 3 days of the study had a higher risk of death, after adjusting for other important predictors of outcome (odds ratio 1.48; 95% CI 1.03–2.12, P = 0.03). Conclusions Both plasma and edema fluid levels of sICAM-1 are higher in patients with ALI than in patients with hydrostatic pulmonary edema. Higher plasma sICAM-1 levels and increasing sICAM-1 levels over time are associated with poor clinical outcomes in ALI. Measurement of sICAM-1 levels may be useful for identifying patients at highest risk of poor outcomes from ALI. PMID:18670758
Water Immersion Affects Episodic Memory and Postural Control in Healthy Older Adults.
Bressel, Eadric; Louder, Talin J; Raikes, Adam C; Alphonsa, Sushma; Kyvelidou, Anastasia
2018-05-04
Previous research has reported that younger adults make fewer cognitive errors on an auditory vigilance task while in chest-deep water compared with on land. The purpose of this study was to extend this previous work to include older adults and to examine the effect of environment (water vs land) on linear and nonlinear measures of postural control under single- and dual-task conditions. Twenty-one older adult participants (age = 71.6 ± 8.34 years) performed a cognitive (auditory vigilance) and motor (standing balance) task separately and simultaneously on land and in chest-deep water. Listening errors (n = count) from the auditory vigilance test and sample entropy (SampEn), center of pressure area, and velocity for the balance test served as dependent measures. Environment (land vs water) and task (single vs dual) comparisons were made with a Wilcoxon matched-pair test. Listening errors were 111% greater during land than during water environments (single-task = 4.0 ± 3.5 vs 1.9 ± 1.7; P = .03). Conversely, SampEn values were 100% greater during water than during land environments (single-task = 0.04 ± 0.01 vs 0.02 ± 0.01; P < .001). Center of pressure area and velocity followed a similar trend to SampEn with respect to environment differences, and none of the measures were different between single- and dual-task conditions (P > .05). The findings of this study expand current support for the potential use of partial aquatic immersion as a viable method for challenging both cognitive and motor abilities in older adults.
Brifkani, Zaid; Brennan, Daniel C; Lentine, Krista L; Horwedel, Timothy A; Malone, Andrew F; Delos Santos, Rowena; Maw, Thin Thin; Alhamad, Tarek
2017-03-01
White recipients of 2-haplotype HLA-matched living kidney transplants are perceived to be of low immunologic risk. Little is known about the safety of induction avoidance and calcineurin inhibitor withdrawal in these patients. We reviewed our experience at a single center and compared it to Organ Procurement and Transplantation Network (OPTN) registry data and only included 2-haplotype HLA-matched white living kidney transplants recipients between 2000 and 2013. There were 56 recipients in a single center (where no induction was given) and 2976 recipients in the OPTN. Among the OPTN recipients, 1285 received no induction, 903 basiliximab, 608 thymoglobulin, and 180 alemtuzumab. First-year acute rejection rates were similar after induction-free transplantation among the center and induced groups nationally. Compared with induction-free transplantation in the national data, there was no decrease in graft failure risk over 13 years with use of basiliximab (adjusted hazard ratio [aHR], 0.86; confidence interval [CI], 0.68-1.08), Thymoglobulin (aHR, 0.92; CI, 0.7-1.21) or alemtuzumab (aHR, 1.18; CI, 0.72-1.93). Among induction-free recipients at the center, calcineurin inhibitor withdrawal at 1 year (n = 27) did not significantly impact graft failure risk (HR,1.62; CI, 0.38-6.89). This study may serve as a foundation for further studies to provide personalized, tailored, immunosuppression for this very low-risk population of kidney transplant patients.
Billiot, Fereshteh H; Billiot, Eugene J; Ng, Yuen Kwun; Warner, Isiah M
2006-02-01
In this study, 18 polymeric single amino acid and dipeptide surfactants are examined, and their performances, in terms of enantioselectivity, are compared for norlaudanosoline, laudanosoline, laudanosine, chlorthalidone, benzoin, benzoin methyl, and benzoin ethyl enantiomers. Several aspects of amino acid-based polymeric surfactants including comparison of single amino acid versus dipeptide, amino acid order, steric effect, and effect of the position of the chiral center of dipeptide surfactants on the chiral selectivity of these optically active compounds are discussed.
Multi-Core Processor Memory Contention Benchmark Analysis Case Study
NASA Technical Reports Server (NTRS)
Simon, Tyler; McGalliard, James
2009-01-01
Multi-core processors dominate current mainframe, server, and high performance computing (HPC) systems. This paper provides synthetic kernel and natural benchmark results from an HPC system at the NASA Goddard Space Flight Center that illustrate the performance impacts of multi-core (dual- and quad-core) vs. single core processor systems. Analysis of processor design, application source code, and synthetic and natural test results all indicate that multi-core processors can suffer from significant memory subsystem contention compared to similar single-core processors.
Validation of Single-Item Screening Measures for Provider Burnout in a Rural Health Care Network.
Waddimba, Anthony C; Scribani, Melissa; Nieves, Melinda A; Krupa, Nicole; May, John J; Jenkins, Paul
2016-06-01
We validated three single-item measures for emotional exhaustion (EE) and depersonalization (DP) among rural physician/nonphysician practitioners. We linked cross-sectional survey data (on provider demographics, satisfaction, resilience, and burnout) with administrative information from an integrated health care network (1 academic medical center, 6 community hospitals, 31 clinics, and 19 school-based health centers) in an eight-county underserved area of upstate New York. In total, 308 physicians and advanced-practice clinicians completed a self-administered, multi-instrument questionnaire (65.1% response rate). Significant proportions of respondents reported high EE (36.1%) and DP (9.9%). In multivariable linear mixed models, scores on EE/DP subscales of the Maslach Burnout Inventory were regressed on each single-item measure. The Physician Work-Life Study's single-item measure (classifying 32.8% of respondents as burning out/completely burned out) was correlated with EE and DP (Spearman's ρ = .72 and .41, p < .0001; Kruskal-Wallis χ(2) = 149.9 and 56.5, p < .0001, respectively). In multivariable models, it predicted high EE (but neither low EE nor low/high DP). EE/DP single items were correlated with parent subscales (Spearman's ρ = .89 and .81, p < .0001; Kruskal-Wallis χ(2) = 230.98 and 197.84, p < .0001, respectively). In multivariable models, the EE item predicted high/low EE, whereas the DP item predicted only low DP. Therefore, the three single-item measures tested varied in effectiveness as screeners for EE/DP dimensions of burnout. © The Author(s) 2015.
Williams, Richard V; Ravishankar, Chitra; Zak, Victor; Evans, Frank; Atz, Andrew M; Border, William L; Levine, Jami; Li, Jennifer S; Mahony, Lynn; Mital, Seema; Pearson, Gail D; Prakash, Ashwin; Hsu, Daphne T
2010-01-01
Although congenital heart disease is associated with low birth weight and prematurity, there is little information about these birth outcomes in infants with single ventricle physiology. We describe the birth outcomes (i.e., gestational age and birth weight) in neonates with single ventricle physiology screened for enrollment in the Pediatric Heart Network's Infant Single Ventricle Trial, compare these outcomes with US norms, and examine the association of birth outcomes with anatomic diagnosis and race. All neonates with single ventricle physiology presenting to Infant Single Ventricle Trial centers were screened for enrollment. Demographic data and anatomic diagnoses were obtained from medical records. A total of 1245 neonates with single ventricle physiology were screened at 10 centers (63 to 266 per center). Diagnoses included hypoplastic left heart syndrome in 49%, unbalanced atrioventricular septal defect in 12%, and tricuspid atresia in 9%. Preterm birth occurred in 16% of neonates with single ventricle physiology vs. 12% in normal neonates (P < .001), low birth weight (<2.5 kg) in 18% vs. 8% in normals (P < .001), and small for gestational age (<10th percentile by definition) in 22% vs. 10% in normals (P < .001). A genetic syndrome was reported in 8%. The percentage of preterm birth, low birth weight, and small for gestational age was similar between screened neonates with and without hypoplastic left heart syndrome. In this large, contemporary cohort of neonates with single ventricle physiology, rates of preterm birth, low birth weight, and small for gestational age were higher than in the general population, but similar between screened neonates with and without hypoplastic left heart syndrome.
Behind the Mosaic: Insurgent Centers of Gravity and Counterinsurgency
2011-12-01
centers of gravity vary by time, space , and purpose. While Clausewitz’s key statement on a center of gravity defines a single center of gravity, he...explicitly or implicitly, that multiple centers of gravity can vary with time, space , and purpose. Shimon Naveh Retired Israeli Reserve Brigadier...century military forces, which in turn expanded operations in time and space . The integration of operations distributed in time and space distributed
Epitaxial Growth of an Organic p-n Heterojunction: C60 on Single-Crystal Pentacene.
Nakayama, Yasuo; Mizuno, Yuta; Hosokai, Takuya; Koganezawa, Tomoyuki; Tsuruta, Ryohei; Hinderhofer, Alexander; Gerlach, Alexander; Broch, Katharina; Belova, Valentina; Frank, Heiko; Yamamoto, Masayuki; Niederhausen, Jens; Glowatzki, Hendrik; Rabe, Jürgen P; Koch, Norbert; Ishii, Hisao; Schreiber, Frank; Ueno, Nobuo
2016-06-01
Designing molecular p-n heterojunction structures, i.e., electron donor-acceptor contacts, is one of the central challenges for further development of organic electronic devices. In the present study, a well-defined p-n heterojunction of two representative molecular semiconductors, pentacene and C60, formed on the single-crystal surface of pentacene is precisely investigated in terms of its growth behavior and crystallographic structure. C60 assembles into a (111)-oriented face-centered-cubic crystal structure with a specific epitaxial orientation on the (001) surface of the pentacene single crystal. The present experimental findings provide molecular scale insights into the formation mechanisms of the organic p-n heterojunction through an accurate structural analysis of the single-crystalline molecular contact.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tait, Steven L.
Stabilization and chemical control of transition metal centers is a critical problem in the advancement of heterogeneous catalysts to next-generation catalysts that exhibit high levels of selectivity, while maintaining strong activity and facile catalyst recycling. Supported metal nanoparticle catalysts typically suffer from having a wide range of metal sites with different coordination numbers and varying chemistry. This project is exploring new possibilities in catalysis by combining features of homogeneous catalysts with those of heterogeneous catalysts to develop new, bi-functional systems. The systems are more complex than traditional heterogeneous catalysts in that they utilize sequential active sites to accomplish the desiredmore » overall reaction. The interaction of metal—organic catalysts with surface supports and their interactions with reactants to enable the catalysis of critical reactions at lower temperatures are at the focus of this study. Our work targets key fundamental chemistry problems. How do the metal—organic complexes interact with the surface? Can those metal center sites be tuned for selectivity and activity as they are in the homogeneous system by ligand design? What steps are necessary to enable a cooperative chemistry to occur and open opportunities for bi-functional catalyst systems? Study of these systems will develop the concept of bringing together the advantages of heterogeneous catalysis with those of homogeneous catalysis, and take this a step further by pursuing the objective of a bi-functional system. The use of metal-organic complexes in surface catalysts is therefore of interest to create well-defined and highly regular single-site centers. While these are not likely to be stable in the high temperature environments (> 300 °C) typical of industrial heterogeneous catalysts, they could be applied in moderate temperature reactions (100-300 °C), made feasible by lowering reaction temperatures by better catalyst control. They also serve as easily tuned model systems for exploring the chemistry of single-site transition metals and tandem catalysts that could then be developed into a zeolite or other stable support structures. In this final technical report, three major advances our described that further these goals. The first is a study demonstrating the ability to tune the oxidation state of V single-site centers on a surface by design of the surrounding ligand field. The synthesis of the single-site centers was developed in a previous reporting period of this project and this new advance shows a distinct new ability of the systems to have a designed oxidation state of the metal center. Second, we demonstrate metal complexation at surfaces using vibrational spectroscopy and also show a metal replacement reaction on Ag surfaces. Third, we demonstrate a surface-catalyzed dehydrocyclization reaction important for metal-organic catalyst design at surfaces.« less
A Long DNA Segment in a Linear Nanoscale Paul Trap
DOE Office of Scientific and Technical Information (OSTI.GOV)
Joseph, Sony nmn; Guan, Weihau; Reed, Mark A
2009-01-01
We study the dynamics of a linearly distributed line charge such as single stranded DNA (ssDNA) in a nanoscale, linear 2D Paul trap in vacuum. Using molecular dynamics simulations we show that a line charge can be trapped effectively in the trap for a well defined range of stability parameters. We investigated (i) a flexible bonded string of charged beads and (ii) a ssDNA polymer of variable length, for various trap parameters. A line charge undergoes oscillations or rotations as it moves, depending on its initial angle, the position of the center of mass and the velocity. The stability regionmore » for a strongly bonded line of charged beads is similar to that of a single ion with the same charge to mass ratio. Single stranded DNA as long as 40 nm does not fold or curl in the Paul trap, but could undergo rotations about the center of mass. However, we show that a stretching field in the axial direction can effectively prevent the rotations and increase the confinement stability.« less
Rojas-Campos, Enrique; Alcántar-Medina, Mario; Cortés-Sanabria, Laura; Martínez-Ramírez, Héctor R; Camarena, José L; Chávez, Salvador; Flores, Antonio; Nieves, Juan J; Monteón, Francisco; Gómez-Navarro, Benjamin; Cueto-Manzano, Alfonso M
2007-01-01
In Mexico, CAPD survival has been analyzed in few studies from the center of the country. However, there are concerns that such results may not represent what occurs in other province centers of our country, particularly in our geographical area. To evaluate the patient and technique survival on CAPD of a single center of the west of Mexico, and compare them with other reported series. Retrospective cohort study. Tertiary care, teaching hospital located in Guadalajara, Jalisco. Patients from our CAPD program (1999-2002) were retrospectively studied. Interventions. Clinical and biochemical variables at the start of dialysis and at the end of the follow-up were recorded and considered in the analysis of risk factors. Endpoints were patient (alive, dead or lost to follow-up) and technique status at the end of the study (June 2002). 49 patients were included. Mean patient survival (+/- SE) was 3.32 +/- 0.22 years (CI 95%: 2.9-3.8 years). Patients in the present study were younger (39 +/- 17yrs), had larger body surface area (1.72 +/- 0.22 m2), lower hematocrit (25.4 +/- 5.2%), albumin (2.6 +/- 0.6g/dL), and cholesterol (173 +/- 44 mg/dL), and higher urea (300 +/- 93 mg/dL) and creatinine (14.9 +/- 5.6 mg/ dL) than those in other Mexican series. In univariate analysis, the following variables were associated (p < 0.05) to mortality: pre-dialysis age and creatinine clearance, and serum albumin and cholesterol at the end of follow-up. In multivariate analysis, only pre-dialysis creatinine clearance (RR 0.66, p = 0.03) and age (RR 1.08, p = 0.005) significantly predicted mortality. Mean technique survival was 2.83 +/- 0.24 years (CI 95%: 2.4-3.3). Pre-dialysis age (p < 0.05), peritonitis rate (p < 0.05), and serum phosphorus at the end of follow-up (p < 0.05) were associated with technique failure in univariate analysis, while in multivariate analysis, only pre-dialysis age (RR 1.07, p = 0.001) and peritonitis rate (RR 481, p < 0.0001) were technique failure predictors. Patients from this single center of the west of Mexico were younger, had higher body surface area and initiated peritoneal dialysis with a more deteriorated general status than patients reported in other Mexican series; in spite of the latter, patient and technique survival were not different. In our setting, pre-dialysis older age and lower CrCl significantly predicted mortality, while older predialysis age and higher peritonitis rate predicted technique failure.
Alhossan, Abdulaziz; Kennedy, Amy; Leal, Sandra
2016-02-15
The clinical and financial outcomes of annual wellness visits (AWVs) conducted by clinical pharmacists working as part of an accountable care organization (ACO) in a federally qualified health center were evaluated. In this retrospective, single-center, chart review study, patients seen for AWVs at El Rio Health Center between October and December 2013 were eligible for study inclusion. Data collected from patient charts included patient demographics, preventive screenings ordered by clinical pharmacists during the AWV and completed within one month after the visit, other screenings completed by clinical pharmacists during the visit, medication changes by clinical pharmacists, and revenues collected from the AWV and preventive screenings. Descriptive statistics were calculated and variables compared; p values were calculated using single-sample Student's t tests. Three hundred patient records were reviewed. Clinical pharmacists completed 1608 interventions, with a mean of 5.4 interventions per patient. A total of 272 referrals were made, 120 (45%) of which were completed within one month of the visit. Of the 183 laboratory tests ordered for diabetes and lipid screening, 152 (83%) were completed within one month of the AWV (p < 0.001). Of the 370 vaccinations offered during the visits, 182 (49%) were administered (p < 0.001). Twenty-four medication and dosage changes were made by clinical pharmacists during AWVs, and the total revenue for the AWVs conducted by pharmacists and services completed during the visits exceeded $22,000. Recommendations made by pharmacists during AWVs in an ACO associated with a federally qualified health center had a high acceptance rate and generated substantial revenue. Copyright © 2016 by the American Society of Health-System Pharmacists, Inc. All rights reserved.
ERIC Educational Resources Information Center
PEPNet, 2009
2009-01-01
PEPNet's "Perspectives" is the collaborative newsletter of the four PEPNet regional centers. This newsletter combines each centers individual strengths into a single resource that can be used on a national level. The issue focuses on the following topics: (1) Web Tool Locates Needed Resources; (2) Family Center on Technology and Disability (Ana…
A novel numerical framework for self-similarity in plasticity: Wedge indentation in single crystals
NASA Astrophysics Data System (ADS)
Juul, K. J.; Niordson, C. F.; Nielsen, K. L.; Kysar, J. W.
2018-03-01
A novel numerical framework for analyzing self-similar problems in plasticity is developed and demonstrated. Self-similar problems of this kind include processes such as stationary cracks, void growth, indentation etc. The proposed technique offers a simple and efficient method for handling this class of complex problems by avoiding issues related to traditional Lagrangian procedures. Moreover, the proposed technique allows for focusing the mesh in the region of interest. In the present paper, the technique is exploited to analyze the well-known wedge indentation problem of an elastic-viscoplastic single crystal. However, the framework may be readily adapted to any constitutive law of interest. The main focus herein is the development of the self-similar framework, while the indentation study serves primarily as verification of the technique by comparing to existing numerical and analytical studies. In this study, the three most common metal crystal structures will be investigated, namely the face-centered cubic (FCC), body-centered cubic (BCC), and hexagonal close packed (HCP) crystal structures, where the stress and slip rate fields around the moving contact point singularity are presented.
The accumulation of femtosecond laser radiation energy in crystals of lithium fluoride
NASA Astrophysics Data System (ADS)
Dresvyanskiy, V. P.; Glazunov, D. S.; Alekseev, S. V.; Losev, V. F.; Chadraa, B.; Bukhtsooj, O.; Baasankhuu, N.; Zandan, B.; Martynovich, E. F.
2015-12-01
We present the results of studies of energy accumulation during the non-destructive interaction of extremely intense near infrared laser radiation with model wide band gap dielectric crystals of lithium fluoride, when the intensity of pulses is sufficient for effective highly nonlinear absorption of light and for the excitation of the electron subsystem of matter and the energy of pulses is still not sufficient for significant heating, evaporation, laser breakdown or other destruction to occur. We studied the emission of energy in the form of light sum of thermally stimulated luminescence accumulated under conditions of self-focusing and multiple filamentation of femtosecond laser radiation. It was established that it's the F2 and F3+ color centers and supplementary to them centers of interstitial type which accumulate energy under the action of a single femtosecond laser pulses. When irradiated by series of pulses the F3, F3- and F4 centers additionally appear. F2 centers are the main centers of emission in the process of thermally stimulated luminescence of accumulated energy. The interstitial fluoride ions (I-centers) are the kinetic particles. They split off from the X3- centers in the result of thermal decomposition of latter on the I-centers and molecules X20. I-centers recombine with F3+ centers and form F2 centers in excited state. The latter produce the characteristic emission spectrum emitted in the form of thermally stimulated luminescence.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shimo-Oka, T.; Miwa, S.; Suzuki, Y.
2015-04-13
Individual nuclear spins in diamond can be optically detected through hyperfine couplings with the electron spin of a single nitrogen-vacancy (NV) center; such nuclear spins have outstandingly long coherence times. Among the hyperfine couplings in the NV center, the nearest neighbor {sup 13}C nuclear spins have the largest coupling strength. Nearest neighbor {sup 13}C nuclear spins have the potential to perform fastest gate operations, providing highest fidelity in quantum computing. Herein, we report on the control of coherences in the NV center where all three nearest neighbor carbons are of the {sup 13}C isotope. Coherence among the three and fourmore » qubits are generated and analyzed at room temperature.« less
Biodegradable Sonobuoy Decelerators
2015-06-01
material. Two materials studied were polyvinyl alcohol (PVOH) and polyhydroxyalkanoate (PHA). Single and multilayered PVOH films were evaluated as well...readiness point for technology transition. 15. SUBJECT TERMS biodegrade, decelerator, sonobuoy, polyvinyl alcohol, polyhydroxyalkanoate , marine...Center NGO non-governmental organizations NOAA National Oceanic and Atmospheric Administration PHA polyhydroxyalkanoate PIA Parachute Industry
"The Single-Parent Family" and Welfare Reform: Is Marriage the Solution?
ERIC Educational Resources Information Center
Fitchen, Janet M.
1995-01-01
Many proposals for welfare reform center on the issue of marriage-based families versus single-parent families and oversimplify the relationship between single-parenting and poverty. Research done in upstate rural New York among low-income families showed that personal and economic characteristics of married and single mothers were similar as to…
Mujtaba, Alhasan; Taher, Mohammed A; Hazza, Mazin A; Al-Rubaye, Hassan M; Kata, Asaad H; AbdulWahab, Hamid; AbdulBari, AbdulAmeer; AlRubay, Hayder K
2018-05-21
Patients undergoing coronary catheterization are at high risk of developing contrast-induced nephropathy (CIN) acute kidney injury (AKI). Several approaches have been supposed to limit such an effect but with mixed results or non-practical methods. Spironolactone is supposed to be effective as a nephroprotective agent in animal studies. This study will try to measure the effect of spironolactone on the incidence of CIN-AKI in patients undergoing coronary catheterization (angiography angioplasty). This study is a single-center, investigator-driven, double-blinded randomized controlled study in Iraq-Basra. More than 400 patients admitted for coronary angio unit in our center will be allocated in a 1:1 ratio to receive either spironolactone 200 mg single dose or placebo in addition to their usual premedication. Primary end point will be CIN defined as more than 25% or 0.3 mg/dl elevation in serum creatinine (S.Cr.) from baseline during the first 2-3 days after the procedure. We hope to identify or answer an important question regarding CIN in such high-risk patients. ClinicalTrials.gov Identifier, NCT03329443.
Unmasking the Secrets of Mercury
2015-04-16
The MASCS instrument onboard NASA MESSENGER spacecraft was designed to study both the exosphere and surface of Mercury. To learn more about the minerals and surface processes on Mercury, the Visual and Infrared Spectrometer (VIRS) portion of MASCS has been diligently collecting single tracks of spectral surface measurements since MESSENGER entered orbit. The track coverage is now extensive enough that the spectral properties of both broad terrains and small, distinct features such as pyroclastic vents and fresh craters can be studied. To accentuate the geological context of the spectral measurements, the MASCS data have been overlain on the MDIS monochrome mosaic. Click on the image to explore the colorful diversity of surface materials in more detail! Instrument: Mercury Atmosphere and Surface Composition Spectrometer (MASCS) Map Projection: Orthographic VIRS Color Composite Wavelengths: 575 nm as red, 415 nm/750 nm as green, 310 nm/390 nm as blue Center Latitude (All Globes): 0° Center Longitude (Top Left Globe): 270° E Center Longitude (Top Right Globe): 0° E Center Longitude (Bottom Left Globe): 90° E Center Longitude (Bottom Right Globe): 180° E http://photojournal.jpl.nasa.gov/catalog/PIA19419
Binding and Translocation of Termination Factor Rho Studied at the Single-Molecule Level
Koslover, Daniel J.; Fazal, Furqan M.; Mooney, Rachel A.; Landick, Robert; Block, Steven M.
2012-01-01
Rho termination factor is an essential hexameric helicase responsible for terminating 20–50% of all mRNA synthesis in E. coli. We used single- molecule force spectroscopy to investigate Rho-RNA binding interactions at the Rho- utilization (rut) site of the ? tR1 terminator. Our results are consistent with Rho complexes adopting two states, one that binds 57 ±2 nucleotides of RNA across all six of the Rho primary binding sites, and another that binds 85 ±2 nucleotides at the six primary sites plus a single secondary site situated at the center of the hexamer. The single-molecule data serve to establish that Rho translocates 5′-to-3′ towards RNA polymerase (RNAP) by a tethered-tracking mechanism, looping out the intervening RNA between the rut site and RNAP. These findings lead to a general model for Rho binding and translocation, and establish a novel experimental approach that should facilitate additional single- molecule studies of RNA-binding proteins. PMID:22885804
Compendium of NASA Langley reports on hypersonic aerodynamics
NASA Technical Reports Server (NTRS)
Sabo, Frances E.; Cary, Aubrey M.; Lawson, Shirley W.
1987-01-01
Reference is made to papers published by the Langley Research Center in various areas of hypersonic aerodynamics for the period 1950 to 1986. The research work was performed either in-house by the Center staff or by other personnel supported entirely or in part by grants or contracts. Abstracts have been included with the references when available. The references are listed chronologically and are grouped under the following general headings: (1) Aerodynamic Measurements - Single Shapes; (2) Aerodynamic Measurements - Configurations; (3) Aero-Heating; (4) Configuration Studies; (5) Propulsion Integration Experiment; (6) Propulsion Integration - Study; (7) Analysis Methods; (8) Test Techniques; and (9) Airframe Active Cooling Systems.
Multi-Institution Research Centers: Planning and Management Challenges
ERIC Educational Resources Information Center
Spooner, Catherine; Lavey, Lisa; Mukuka, Chilandu; Eames-Brown, Rosslyn
2016-01-01
Funding multi-institution centers of research excellence (CREs) has become a common means of supporting collaborative partnerships to address specific research topics. However, there is little guidance for those planning or managing a multi-institution CRE, which faces specific challenges not faced by single-institution research centers. We…
77 FR 22326 - Board of Scientific Counselors, National Center for Health Statistics, (BSC, NCHS)
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-13
... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Board of...) of the Federal Advisory Committee Act (Pub. L. 92-463), the Centers for Disease Control and..., and organizational affiliation of the presenter. Written comments should not exceed five single-spaced...
Strategic hospital partnerships: improved access to care and increased epilepsy surgical volume.
Vadera, Sumeet; Chan, Alvin Y; Mnatsankanyan, Lilit; Sazgar, Mona; Sen-Gupta, Indranil; Lin, Jack; Hsu, Frank P K
2018-05-01
OBJECTIVE Surgical treatment of patients with medically refractory focal epilepsy is underutilized. Patients may lack access to surgically proficient centers. The University of California, Irvine (UCI) entered strategic partnerships with 2 epilepsy centers with limited surgical capabilities. A formal memorandum of understanding (MOU) was created to provide epilepsy surgery to patients from these centers. METHODS The authors analyzed UCI surgical and financial data associated with patients undergoing epilepsy surgery between September 2012 and June 2016, before and after institution of the MOU. Variables collected included the length of stay, patient age, seizure semiology, use of invasive monitoring, and site of surgery as well as the monthly number of single-surgery cases, complex cases (i.e., staged surgeries), and overall number of surgery cases. RESULTS Over the 46 months of the study, a total of 104 patients underwent a total of 200 operations; 71 operations were performed in 39 patients during the pre-MOU period (28 months) and 129 operations were performed in 200 patients during the post-MOU period (18 months). There was a significant difference in the use of invasive monitoring, the site of surgery, the final therapy, and the type of insurance. The number of single-surgery cases, complex-surgery cases, and the overall number of cases increased significantly. CONCLUSIONS Partnerships with outside epilepsy centers are a means to increase access to surgical care. These partnerships are likely reproducible, can be mutually beneficial to all centers involved, and ultimately improve patient access to care.
Study to determine the IFR operational profile and problems to the general aviation pilot
NASA Technical Reports Server (NTRS)
Weislogel, S.
1983-01-01
A study of the general aviation single pilot operating under instrument flight rules (GA SPIFR) has been conducted for NASA Langley Research Center. The objectives of the study were to (1) develop a GA SPIFR operational profile, (2) identify problems experienced by the GA SPIFR pilot, and (3) identify research tasks which have the potential for eliminating or reducing the severity of the problems. To obtain the information necessary to accomplish these objectives, a mail questionnaire survey of instrument rated pilots was conducted. Complete questionnaire data is reported in NASA CR-165805, "Statistical Summary: Study to Determine the IFR Operational Profile and Problems of the General Aviation Single Pilot'-Based upon the results of the GA SPIFR survey, this final report presents the general aviation IFR single pilot operational profile, illustrates selected data analysis, examples, identifies the problems which he is experiencing, and recommends further research.
Magnetic rotational hysteresis study on spherical 85-160 nm Fe3O4 particles
NASA Astrophysics Data System (ADS)
Schmidbauer, E.
1988-05-01
Rotational hysteresis losses Wr were determined as a function of magnetic field H for dispensed spherical Fe3O4 particles of mean grain sizes 85 nm, 127 nm and 162 nm between 78 K and 294 K. The observed Wr-H curves are compared with theoretical curves for single domain particles. The analysed particles reveal centers of high magnetic anisotropy. Such centers can be of importance during the generation of a thermoremanent magnetization, as they may be the origin of enhanced magnetic stability.
Earthquake studies reveal the magmatic plumbing system of the Katmai volcanoes
Thurber, Clifford; Murphy, Rachel; Prejean, Stephanie G.; Haney, Matthew M.; Bennington, Ninfa; Powell, Lee; Paskievitch, John F.
2012-01-01
Our main finding is that there is not a single large anomalous zone centered beneath Katmai Pass; rather there are several separate anomalous zones, one each beneath Katmai, Trident-Novarupta, and Martin-Mageik. Furthermore, the earthquakes are tightly clustered beneath the various volcanic centers, and are found to be systematically deeper than previously thought. Linear trends of earthquakes are also revealed, similar to features observed at other volcanoes, possibly outlining previously unidentified fault structures or indicating the path of migrating magma or magmatic fluids and gases.
Hydroxyapatite ceramic implants for cranioplasty in children: a single-center experience.
Zaccaria, Laura; Tharakan, Sasha Job; Altermatt, Stefan
2017-02-01
The use of hydroxyapatite ceramic (HAC) implants for the treatment of skull defects in pediatric patients started 2010 at our institution. Ceramic implants facilitate osteoblast migration and therefore optimize osteointegration with the host bone. The purpose of this study is to report a single-center experience with this treatment modality. A retrospective review of all patients from July 2010 through June 2014 undergoing a cranioplasty using hydroxyapatite ceramic implant and managed at a single institution was performed. Indication for cranioplasty, the hospital course, and follow-up were reviewed. Bone density was measured in Hounsfield Units (HU) and osteointegration was calculated using Mimics Software® (Mimics Innovation Suite v17.0 Medical, Materialize, Leuven, Belgium). Over the 4-year period, six patients met criteria for the study. Five patients had an osteointegration of nearly 100%. One patient had an incomplete osteointegration with a total bone-implant contact area of 69%. The mean bone density was 2800 HU (2300-3000 HU). Bone density alone is estimated to have a Hounsfield value between 400 and 2000 HU depending on the body region and bone quality. There were no major complications, and the patients were highly satisfied with the esthetical result. Hydroxyapatite ceramic implants for cranioplasty in pediatric patients are a good choice for different indications. The implants show excellent osteointegration and esthetical results.
[Study on single-walled carbon nanotube thin film photoelectric device].
Xie, Wen-bin; Zhu, Yong; Gong, Tian-cheng; Chen, Yu-lin; Zhang, Jie
2015-01-01
The single-walled carbon nanotube film photoelectric device was invented, and it can generate net photocurrent under bias voltage when it is illuminated by the laser. The influences of bias voltage, laser power and illuminating position on the net photocurrent were investigated. The experimental results showed that when the center of the film was illuminated, the photocurrent increased with the applied bias, but tended to saturate as the laser power increased. As the voltage and the laser power reached 0. 2 V and 22. 7 mW respectively, the photocurrent reached 0. 24 µA. When the voltage was removed, the photocurrent varied with the laser illuminating position on the film and its value was distributed symmetrically about the center of the device. The photocurrent reached maximum and almost zero respectively when the laser illuminated on two ends and the center of the film. Analysis proposes that the net photocurrent can be generated due to internal photoelectric effect when the device is under voltage and the laser illuminates on the center of the film. It can be also generated due to photo-thermoelectric effect when the device is under no voltage and the laser illuminates on the film, and the relation between the net photocurrent and the illuminating position was derived according to the nature of thermoelectric power of single-walled carbon nanotubes with the established temperature model, which coincides with experimental result. Two effects are the reasons for the generation and variety of the net photocurrent and they superimpose to form the result of the net photocurrent when the device is under general conditions of voltage and laser illuminating position. The device has potential applications in the areas of photovoltaic device and optical sensor for its characteristic.
Kute, Vivek B; Godara, Suraj M; Shah, Pankaj R; Jain, Siddharth H; Engineer, D P; Patel, Himanshu V; Gumber, Manoj R; Munjappa, Bipin C; Sainaresh, V V; Vanikar, Aruna V; Modi, Pranjal R; Shah, Veena R; Trivedi, Hargovind L
2012-02-01
Type 2 diabetes mellitus (DM) is the commonest cause of end-stage renal disease (ESRD) worldwide. Renal transplantation (RTx) is the best therapeutic modality for such patients. First-degree relatives of patients with type 2 DM have high risk of diabetes/pre-diabetes. Parents are often too old to be suitable donors, and siblings/children/spouse are either not suitable/acceptable or do not come forward for organ donation. This leaves deceased donation (DD) as only suitable donors. Data scarcity on DDRTx outcome in diabetic nephropathy (DN) prompted us to review our experience. This retrospective single-center 10-year study was undertaken to evaluate patient/graft survival, graft function, rejection episodes, and mortality in these patients. Between January 2001 and March 2011, thirty-five DN-ESRD patients underwent DDRTx in our center following cardiac fitness assessment of recipients. All patients received single-dose rabbit-anti-thymocyte globulin for induction and steroids, calcineurin inhibitor, and mycophenolate mofetil/azathioprine for maintenance immunosuppression. Mean recipient age was 49.66 ± 6.76 years, and 25 were men. Mean donor age was 50 ± 16.45 years, 23 were men. Over a mean follow-up of 2.28 ± 2.59 years, patient and graft survival rates were 68.5% and 88.5%, respectively, with mean SCr of 1.9 ± 0.62 mg/dl. Delayed graft function was observed in 34.3% patients, and 25.7% had biopsy-proven acute rejection; 31.5% patients died, mainly because of infections (22.8%), coronary artery disease (2.86%), and cerebrovascular events (5.7%). DDRTx in patients with DN has acceptable graft function and patient/graft survival over 10-year follow-up in our center and, therefore, we believe it should be encouraged.
de Carvalho, Guilherme Moreira; Sponchiado Junior, Emílio Carlos; Garrido, Angela Delfina Bittencourt; Lia, Raphael Carlos Comelli; Garcia, Lucas da Fonseca Roberti; Marques, André Augusto Franco
2015-12-01
The aim of this study was to evaluate the apical transportation, the centering ability, and the cleaning effectiveness of a reciprocating single-file system associated to different glide path techniques. The mesial root canals of 52 mandibular molars were randomly distributed into 4 groups (n = 13) according to the different glide path techniques used before biomechanical preparation with Reciproc System (RS): KF/RS (sizes 10 and 15 K-files), NGP/RS (no glide path, only reciprocating system), PF/RS (sizes 13, 16, and 19 PathFile instruments), and NP (no preparation). Cone-beam computed tomography analysis was performed before and after instrumentation for apical third images acquisition. Apical transportation and its direction were evaluated by using the formula D = (X1 - X2) - (Y1 - Y2), and the centering ability was analyzed by the formula CC = (X1 - X2/Y1 - Y2 or Y1 - Y2/X1 - X2). The samples were submitted to histologic processing and analyzed under a digital microscope for debris quantification. The values were statistically analyzed (Kruskal-Wallis, the Dunn multiple comparisons test, P < .05). All groups had similar apical transportation values, with no significant difference among them (P > .05). Groups had a tendency toward transportation in the mesial direction. No technique had perfect centering ability (=1.0), with no significant difference among them. KF/RS had larger amount of debris, with statistically significant difference in comparison with NGP/RS (P > .05). The different glide path techniques promoted minimal apical transportation, and the reciprocating single-file system tested remained relatively centralized within the root canal. Also, the different techniques interfered in the cleaning effectiveness of the reciprocating system. Copyright © 2015 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
2015-01-01
Peptidylglycine monooxygenase (PHM) catalyzes the final step in the biosynthesis of amidated peptides that serve as important signaling molecules in numerous endocrine pathways. The catalytic mechanism has attracted much attention because of a number of unique attributes, including the presence of a pair of uncoupled copper centers separated by 11 Å (termed CuH and CuM), an unusual Cu(I)SMet interaction at the oxygen binding M-site, and the postulated Cu(II)–superoxo intermediate. Understanding the mechanism requires determining the catalytic roles of the individual copper centers and how they change during catalysis, a task made more difficult by the overlapping spectral signals from each copper center in the wild-type (WT) protein. To aid in this effort, we constructed and characterized two PHM variants that bound metal at only one site. The H242A variant bound copper at the H-center, while the H107AH108A double mutant bound copper at the M-center; both mutants were devoid of catalytic activity. Oxidized Cu(II) forms showed electron paramagnetic resonance and extended X-ray absorption fine structure (EXAFS) spectra consistent with their previously determined Cu(II)His3O and Cu(II)His2O2 ligand sets for the H- and M-centers, respectively. Cu(I) forms, on the other hand, showed unique chemistry. The M-center bound two histidines and a methionine at all pHs, while the H-center was two-coordinate at neutral pH but coordinated a new methionine S ligand at low pH. Fourier transform infrared studies confirmed and extended previous assignments of CO binding and showed unambiguously that the 2092 cm–1 absorbing species observed in the WT and many variant forms is an M-site Cu(I)–CO adduct. Silver binding was also investigated. When H107AH108A and M109I (a WT analogue with both sites intact) were incubated with excess AgNO3, each variant bound a single Ag(I) ion, from which it was inferred that Ag(I) binds selectively at the M-center with little or no affinity for the H-center. EXAFS at the Ag K-edge established a strong degree of similarity between the ligand sets of Cu and Ag bound at the M-center. These studies validate previous spectral assignments and provide new insights into the detailed chemistry of each metal site. PMID:24471980
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chuvashova, Irina, E-mail: irina.chuvashova@gmail.com; Bayerisches Geoinstitut, University of Bayreuth, D-95440 Bayreuth; Bykova, Elena
In the present study single crystals of rhombohedral α-B were investigated under pressure to 60 GPa by means of single-crystal X-ray diffraction. The bulk modulus of α-B was found to be K=224(7) GPa (K′=3.0(3)). Measurements of interatomic distances as a function of pressure revealed that the intericosahedral two-center two-electron (2c–2e) bonds are almost as stiff as some of intraicosahedral ones. The three-center two-electron (3c–2e) intericosahedral bonds show much higher compliance compared to other bonds in α-B. The vibrational properties of α-B under pressure were investigated by Raman spectroscopy at pressures up to 160 GPa and IR spectroscopy at pressures upmore » to 53 GPa. - Graphical abstract: The rhombohedral α-B is highly incompressible and extremely stable: it maintains its crystal structure up to 160 GPa and its intericosahedral 2e2c bonds are almost as stiff as some of intraicosahedral ones. - Highlights: • Structural stability of α-B has been investigated up to 160 GPa on single crystals. • Single-crystal x-ray diffraction reveals that α-B is highly incompressible. • Compressibility of B{sub 12} icosahedra is considerably lower than that of the bulk material. • Intericosahedral 2e2c bonds are almost as stiff as some of intraicosahedral ones.« less
Goniotomy with a single-use dual blade: Short-term results.
Greenwood, Michael D; Seibold, Leonard K; Radcliffe, Nathan M; Dorairaj, Syril K; Aref, Ahmad A; Román, Jesús Jimenez; Lazcano-Gomez, Gabriel S; Darlington, Jason K; Abdullah, Suhail; Jasek, Mark C; Bahjri, Khaled A; Berdahl, John P
2017-09-01
To evaluate the intraocular pressure (IOP)-lowering efficacy and safety of a single-use dual blade (Kahook) in patients with mild to end-stage glaucoma. International multicenter ophthalmic care centers. Prospective interventional case series. Consecutive patients with glaucoma who had phacoemulsification plus goniotomy with the single-use dual blade were enrolled in this study. Each center collected deidentified clinical data, including preoperative and postoperative IOP, medication use, adverse events, and whether additional surgery was required during a 6-month follow-up. Of the 71 eyes included in this study, 70% had primary open-angle glaucoma. Other diagnoses included angle-closure, pigmentary, pseudoexfoliative, and normal-tension glaucoma. Sixty-five percent of eyes were classified as having mild to moderate glaucoma and 35%, severe glaucoma. The mean baseline IOP decreased from 17.4 mm Hg ± 5.2 (SD) to 12.8 ± 2.6 mm Hg 6 months postoperatively and the hypotensive medication use decreased from 1.6 ± 1.3 to 0.9 ± 1.0, respectively (P < .001 and P = .005, respectively). The most common observation was blood reflux during surgery (39.4%). Single-use dual blade goniotomy plus phacoemulsification resulted in a significant and sustained reduction in IOP and a decrease in glaucoma medications after 6 months of follow-up. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.
Hawkins, Jared B; Jones, Mark T; Plassmann, Paul E; Thorley-Lawson, David A
2011-01-01
Germinal centers (GCs) are complex dynamic structures that form within lymph nodes as an essential process in the humoral immune response. They represent a paradigm for studying the regulation of cell movement in the development of complex anatomical structures. We have developed a simulation of a modified cyclic re-entry model of GC dynamics which successfully employs chemotaxis to recapitulate the anatomy of the primary follicle and the development of a mature GC, including correctly structured mantle, dark and light zones. We then show that correct single cell movement dynamics (including persistent random walk and inter-zonal crossing) arise from this simulation as purely emergent properties. The major insight of our study is that chemotaxis can only achieve this when constrained by the known biological properties that cells are incompressible, exist in a densely packed environment, and must therefore compete for space. It is this interplay of chemotaxis and competition for limited space that generates all the complex and biologically accurate behaviors described here. Thus, from a single simple mechanism that is well documented in the biological literature, we can explain both higher level structure and single cell movement behaviors. To our knowledge this is the first GC model that is able to recapitulate both correctly detailed anatomy and single cell movement. This mechanism may have wide application for modeling other biological systems where cells undergo complex patterns of movement to produce defined anatomical structures with sharp tissue boundaries.
Single-center experience in double kidney transplantation.
Fontana, I; Magoni Rossi, A; Gasloli, G; Santori, G; Giannone, A; Bertocchi, M; Piaggio, F; Bocci, E; Valente, Umberto
2010-05-01
Use of organs from marginal donors for transplantation is a current strategy to expand the organ donor pool. Its efficacy is universally accepted among data from multicenter studies. Herein, we have reviewed outcomes of double kidney transplantation (DKT) over an 9-year experience in our center. The aim of this study was to evaluate possible important differences between a monocenter versus multicenter studies. Between 1999 and 2008, we performed 59 DKT. Recipient mean age was 63 +/- 5 years. Mean HLA-A, -B, and -DR mismatches were 3.69 +/- 0.922. Donor mean age was 69 +/- 7 years and mean creatinine clearance was 69.8 +/- 30.8 mL/min. Proteinuria was detected in three donors (5%). Mean cold ischemia and warm ischemia times were 1130 +/- 216 and 48 +/- 11 minutes, respectively. The right and left kidney scores were 4.18 +/- 2 and 4.21 +/- 2, respectively. Thirty patients (51%) displayed good postoperative renal function; 22 (37%), acute tubular necrosis with postoperative dialysis; 3 (5%), acute rejection episodes; 4 (7%), single-graft transplantectomy due to vascular thrombosis; 1 (2%), a retransplantation; 5 (8%), a lymphocele; 3 (5%) vescicoureteral reflux or stenosis requiring surgical correction. Cytomegalovirus infection was detected in five patients (8%). In three patients (5%) displayed de novo neoplasia. Three patients showed chronic rejection (5%), whereas we observed a cyclosporine-related toxicity in 7 (12%). Nine patients (15%) developed iatrogenic diabetes. Patient and graft survivals after 3 years from DKT were 93% and 86.3%, respectively. In this study, we applied successfully a widespread score to allocate organs to single kidney transplantation or DKT. In our experience, the score is suitable for the organ allocation but it may be overprotective, excluding potentially suitable organs for a single transplantation. Copyright (c) 2010 Elsevier Inc. All rights reserved.
Economics of data center optics
NASA Astrophysics Data System (ADS)
Huff, Lisa
2016-03-01
Traffic to and from data centers is now reaching Zettabytes/year. Even the smallest of businesses now rely on data centers for revenue generation. And, the largest data centers today are orders of magnitude larger than the supercomputing centers of a few years ago. Until quite recently, for most data center managers, optical data centers were nice to dream about, but not really essential. Today, the all-optical data center - perhaps even an all-single mode fiber (SMF) data center is something that even managers of medium-sized data centers should be considering. Economical transceivers are the key to increased adoption of data center optics. An analysis of current and near future data center optics economics will be discussed in this paper.
Comprehensive Evaluation of Attitude and Orbit Estimation Using Actual Earth Magnetic Field Data
NASA Technical Reports Server (NTRS)
Deutschmann, Julie K.; Bar-Itzhack, Itzhack Y.
2000-01-01
A single, augmented Extended Kalman Filter (EKF), which simultaneously and autonomously estimates spacecraft attitude and orbit has been developed and successfully tested with real magnetometer and gyro data only. Because the earth magnetic field is a function of time and position, and because time is known quite precisely, the differences between the computed and measured magnetic field components, as measured by the magnetometers throughout the entire spacecraft orbit, are a function of both orbit and attitude errors. Thus, conceivably these differences could be used to estimate both orbit and attitude; an observability study validated this assumption. The results of testing the EKF with actual magnetometer and gyro data, from four satellites supported by the NASA Goddard Space Flight Center (GSFC) Guidance, Navigation, and Control Center, are presented and evaluated. They confirm the assumption that a single EKF can estimate both attitude and orbit when using gyros and magnetometers only.
Catalytic reduction of dinitrogen to ammonia at a single molybdenum center.
Yandulov, Dmitry V; Schrock, Richard R
2003-07-04
Dinitrogen (N2) was reduced to ammonia at room temperature and 1 atmosphere with molybdenum catalysts that contain tetradentate [HIPTN3N]3- triamidoamine ligands (such as [HIPTN3N]Mo(N2), where [HIPTN3N]3- is [(3,5-(2,4,6-i-Pr3C6H2)2C6H3NCH2CH2)3N]3-) in heptane. Slow addition of the proton source [(2,6-lutidinium)(BAr'4), where Ar' is 3,5-(CF3)2C6H3]and reductant (decamethyl chromocene) was critical for achieving high efficiency ( approximately 66% in four turnovers). Numerous x-ray studies, along with isolation and characterization of six proposed intermediates in the catalytic reaction under noncatalytic conditions, suggest that N2 was reduced at a sterically protected, single molybdenum center that cycled from Mo(III) through Mo(VI) states.
ERIC Educational Resources Information Center
Myers, Edward L.
2013-01-01
This qualitative single-site case study examined the philosophy, decisions, and behaviors of a particular male school principal who subscribed to a form of care-based leadership practice. A Pennsylvania high school principal with a distinct leadership philosophy centered on the ethic of care was chosen to participate in this study. The purpose of…
Electron Paramagnetic Resonance of a Single NV Nanodiamond Attached to an Individual Biomolecule
NASA Astrophysics Data System (ADS)
Teeling-Smith, Richelle M.; Jung, Young Woo; Scozzaro, Nicolas; Cardellino, Jeremy; Rampersaud, Isaac; North, Justin A.; Šimon, Marek; Bhallamudi, Vidya P.; Rampersaud, Arfaan; Johnston-Halperin, Ezekiel; Poirier, Michael G.; Hammel, P. Chris
2016-05-01
A key limitation of electron paramagnetic resonance (EPR), an established and powerful tool for studying atomic-scale biomolecular structure and dynamics is its poor sensitivity, samples containing in excess of 10^12 labeled biomolecules are required in typical experiments. In contrast, single molecule measurements provide improved insights into heterogeneous behaviors that can be masked by ensemble measurements and are often essential for illuminating the molecular mechanisms behind the function of a biomolecule. We report EPR measurements of a single labeled biomolecule that merge these two powerful techniques. We selectively label an individual double-stranded DNA molecule with a single nanodiamond containing nitrogen-vacancy (NV) centers, and optically detect the paramagnetic resonance of NV spins in the nanodiamond probe. Analysis of the spectrum reveals that the nanodiamond probe has complete rotational freedom and that the characteristic time scale for reorientation of the nanodiamond probe is slow compared to the transverse spin relaxation time. This demonstration of EPR spectroscopy of a single nanodiamond labeled DNA provides the foundation for the development of single molecule magnetic resonance studies of complex biomolecular systems.
MMPI Profiles of Adolescents Charged with Homicide.
ERIC Educational Resources Information Center
Cornell, Dewey G.; And Others
Violent individuals are a heterogeneous group, making it unrealistic to think that a single psychological profile can classify them. Adolescents (N=72) at the Michigan Center for Forensic Psychiatry who had committed homicides were studied in an effort to distinguish clinically meaningful subtypes based on the motives and circumstance of their…
Basic Gravitational Reflexes in the Larval Frog
NASA Technical Reports Server (NTRS)
Cochran, Stephen L.
1996-01-01
This investigation was designed to determine how a primitive vertebrate, the bullfrog tadpole, is able to sense and process gravitational stimuli. Because of the phylogenetic similarities of the vestibular systems in all vertebrates, the understanding of the gravitational reflexes in this relatively simple vertebrate should elucidate a skeletal framework on a elementary level, upon which the more elaborate reflexes of higher vertebrates may be constructed. The purpose of this study was to understand how the nervous system of the larval amphibian processes gravitational information. This study involved predominantly electrophysiological investigations of the isolated, alert (forebrain removed) bullfrog tadpole head. The focus of these experiments is threefold: (1) to understand from whole extraocular nerve recordings the signals sent to the eye following static gravitational tilt of the head; (2) to localize neuronal centers responsible for generating these signals through reversible pharmacological ablation of these centers; and (3) to record intracellularly from neurons within these centers in order to determine the single neuron's role in the overall processing of the center. This study has provided information on the mechanisms by which a primitive vertebrate processes gravitational reflexes.
Restless Leg Syndrome in Different Types of Demyelinating Neuropathies: A Single-Center Pilot Study
Luigetti, Marco; Del Grande, Alessandra; Testani, Elisa; Bisogni, Giulia; Losurdo, Anna; Giannantoni, Nadia Mariagrazia; Mazza, Salvatore; Sabatelli, Mario; Della Marca, Giacomo
2013-01-01
Objective: to determine the prevalence of restless legs syndrome (RLS) in a cohort of patients with demyelinating neuropathies. Methods: Patients were retrospectively recruited from our cohort of different forms of demyelinating neuropathies, including chronic inflammatory demyelinating neuropathy (CIDP), Charcot-Marie-Tooth 1A (CMT1A), and hereditary neuropathy with liability to pressure palsies (HNPP) referred to our Department of Neurology in a 10-year period. The validated 4-item RLS questionnaire was used for diagnosis of RLS. All patients with RLS who fulfilled criteria underwent a suggested immobilization test to confirm the diagnosis. A group of outpatients referred to the sleep disorders unit and data from published literature were used as controls. Results: Prevalence of RLS in demyelinating neuropathy group was higher than prevalence observed in control population (p = 0.0142) or in the literature data (p = 0.0007). In particular, in comparison with both control population and literature data, prevalence of RLS was higher in CIDP group (p = 0.0266 and p = 0.0063, respectively) and in CMT1A group (p = 0.0312 and p = 0.0105, respectively), but not in HNPP (p = 1.000 and p = 0.9320, respectively). Conclusions: our study confirms a high prevalence of RLS in inflammatory neuropathies as CIDP and, among inherited neuropathies, in CMT1A but not in HNPP. Considering that this is only a small cohort from a single-center retrospective experience, the link between RLS and neuropathy remains uncertain, and larger multicenter studies are probably needed to clarify the real meaning of the association between RLS and neuropathy. Citation: Luigetti M; Del Grande A; Testani E; Bisogni G; Losurdo A; Giannantoni NM; Mazza S; Sabatelli M; Della Marca G. Restless leg syndrome in different types of demyelinating neuropathies: a single-center pilot study. J Clin Sleep Med 2013;9(9):945-949. PMID:23997707
Feasibility of zero or near zero fluoroscopy during catheter ablation procedures.
Haegeli, Laurent M; Stutz, Linda; Mohsen, Mohammed; Wolber, Thomas; Brunckhorst, Corinna; On, Chol-Jun; Duru, Firat
2018-04-03
Awareness of risks associated with radiation exposure to patients and medical staff has significantly increased. It has been reported before that the use of advanced three-dimensional electro-anatomical mapping (EAM) system significantly reduces fluoroscopy time, however this study aimed for zero or near zero fluoroscopy ablation to assess its feasibility and safety in ablation of atrial fibrillation (AF) and other tachyarrhythmias in a "real world" experience of a single tertiary care center. This was a single-center study where ablation procedures were attempted without fluoroscopy in 34 consecutive patients with different tachyarrhythmias under the support of EAM system. When transseptal puncture (TSP) was needed, it was attempted under the guidance of intracardiac echocardiography (ICE). Among 34 patients consecutively enrolled in this study, 28 (82.4%) patients were referred for radiofrequency ablation (RFA) of AF, 3 (8.8%) patients for ablation of right ventricular outflow tract (RVOT) ventricular extrasystole (VES), 1 (2.9%) patient for ablation of atrioventricular nodal reentry tachycardia (AVNRT), 2 (5.9%) patients for typical atrial flutter ablation. In 21 (62%) patients the entire procedure was carried out without the use of fluoroscopy. Among 28 AF patients, 15 (54%) patients underwent ablation without the use of fluoroscopy and among these 15 patients, 10 (67%) patients required TSP under ICE guidance while 5 (33%) patients the catheters were introduced to left atrium through a patent foramen ovale. In 13 AF patients, fluoroscopy was only required for double TSP. The total procedure time of AF ablation was 130 ± 50 min. All patients referred for atrial flutter, AVNRT, and VES of the RVOT ablation did not require any fluoroscopy. This study demonstrates the feasibility of zero or near zero fluoroscopy procedure including TSP with the support of EAM and ICE guidance in a "real world" experience of a single tertiary care center. When fluoroscopy was required, it was limited to TSP hence keeping the radiation dose very low. .
ERIC Educational Resources Information Center
Chow, Joseph Kui Foon; Kennedy, Kerry J.
2015-01-01
Researchers in comparative education have suggested different ways in which their field of study can be enhanced by considering units of analysis at different levels rather than focusing on a single level such as the nation-state (Bray and Thomas, 1995; Torney-Purta and Barber, 2011). The study reported here seeks to contribute to this area of…
ERIC Educational Resources Information Center
Brown, Alan
2012-01-01
Research on the occupational socialization of teachers and coaches has largely centered on physical education teachers and rarely on teachers from core content areas (i.e. English, foreign language, mathematics, science and social studies) who also coach athletics. The primary purpose of this single-case study was to explore the socialization of a…
Exploring Artistic Practice in Global Communities of the African Diaspora
ERIC Educational Resources Information Center
Ellis, Auburn E.
2014-01-01
In 2012 an African Centered single case study was conducted in the United States. The problem is as follows: K-12 practitioners in urban areas are faced with unique circumstances while serving marginalized students in urban areas. As a response to this issue, the purpose of this study was to identify and describe curricula used in three African…
A Study on the Employee Turnover Antecedents in ITES/BPO Sector
ERIC Educational Resources Information Center
Sree Rekha, K. R.; Kamalanabhan, T. J.
2010-01-01
This paper aims at testing a conceptual model connecting variables of the internal and external work environment to ITES/BPO employee turnover. Based on the gaps identified from the literature that no single model explains in a comprehensive way as to why, people choose to leave and the lack of turnover studies on call centers located in India.…
Cander, Soner; Gul, Ozen Oz; Gul, Cuma B; Keles, Saadet B; Yavas, Sibel; Ersoy, Canan
2014-12-01
This study evaluated the impact of patient education on adherence to a diabetes care plan (e.g., anthropometric, lipidemic, and glycemic parameters) among adults with type II diabetes mellitus without adequate glycemic control. A total of 61 ambulatory adults with type II diabetes mellitus (mean age: 53.6 ± 8.2 years, 70.5% female) were evaluated for anthropometrics, duration of diabetes mellitus, type of anti-diabetic treatment, blood biochemistry, and glycemic parameters in this 3-month prospective observational single-center study. During the course of the study, participants demonstrated a significant decrease in body weight and fat percentage and HbA1c (p < .001 for each). None of the factors evaluated was a significant determinant for glycemic parameters. These findings revealed that adults with type II diabetes mellitus who received education on adherence to routine self-monitoring of blood glucose, standard diabetic diet, and an exercise program delivered by certified diabetes educators had better glycemic control and significant decrease in body weight and fat percentage over a 3-month monitoring period. Copyright 2014, SLACK Incorporated.
Comparison of a single-channel EEG sleep study to polysomnography
Lucey, Brendan P.; McLeland, Jennifer S.; Toedebusch, Cristina D.; Boyd, Jill; Morris, John C.; Landsness, Eric C.; Yamada, Kelvin; Holtzman, David M.
2016-01-01
Summary An accurate home sleep study to assess electroencephalography (EEG)-based sleep stages and EEG power would be advantageous for both clinical and research purposes, such as for longitudinal studies measuring changes in sleep stages over time. The purpose of this study was to compare sleep scoring of a single-channel EEG recorded simultaneously on the forehead against attended polysomnography. Participants were recruited from both a clinical sleep center and a longitudinal research study investigating cognitively-normal aging and Alzheimer's disease. Analysis for overall epoch-by-epoch agreement found strong and substantial agreement between the single-channel EEG compared to polysomnography (kappa=0.67). Slow wave activity in the frontal regions was also similar when comparing the single-channel EEG device to polysomnography. As expected, stage N1 showed poor agreement (sensitivity 0.2) due to lack of occipital electrodes. Other sleep parameters such as sleep latency and REM onset latency had decreased agreement. Participants with disrupted sleep consolidation, such as from obstructive sleep apnea, also had poor agreement. We suspect that disagreement in sleep parameters between the single-channel EEG and polysomnography is partially due to altered waveform morphology and/or poorer signal quality in the single-channel derivation. Our results show that single-channel EEG provides comparable results to polysomnography in assessing REM, combined stages N2 and N3 sleep, and several other parameters including frontal slow wave activity. The data establish that single-channel EEG can be a useful research tool. PMID:27252090
NASA Earth-to-Orbit Engineering Design Challenges: Thermal Protection Systems
ERIC Educational Resources Information Center
National Aeronautics and Space Administration (NASA), 2010
2010-01-01
National Aeronautics and Space Administration (NASA) Engineers at Marshall Space Flight Center, Dryden Flight Research Center, and their partners at other NASA centers and in private industry are currently developing X-33, a prototype to test technologies for the next generation of space transportation. This single-stage-to-orbit reusable launch…
Plan for the Center for Academic Development at Hamline University.
ERIC Educational Resources Information Center
Johnson, Jack K.
It is recommended that the development and implementation of all new or existing programs related to life-long learning and expansion of opportunities for non-traditional learners at Hamline University be consolidated into a single administrative unit called the Center for Academic Development. The proposed mission of the center, including…
NASA Astrophysics Data System (ADS)
Lai, Yen-Yu; Lin, Guin-Dar; Twamley, Jason; Goan, Hsi-Sheng
2018-05-01
We propose a quantum memory scheme to transfer and store the quantum state of a superconducting flux qubit (FQ) into the electron spin of a single nitrogen-vacancy (NV) center in diamond via yttrium iron garnet (YIG), a ferromagnet. Unlike an ensemble of NV centers, the YIG moderator can enhance the effective FQ-NV-center coupling strength without introducing additional appreciable decoherence. We derive the effective interaction between the FQ and the NV center by tracing out the degrees of freedom of the collective mode of the YIG spins. We demonstrate the transfer, storage, and retrieval procedures, taking into account the effects of spontaneous decay and pure dephasing. Using realistic experimental parameters for the FQ, NV center and YIG, we find that a combined transfer, storage, and retrieval fidelity higher than 0.9, with a long storage time of 10 ms, can be achieved. This hybrid system not only acts as a promising quantum memory, but also provides an example of enhanced coupling between various systems through collective degrees of freedom.
Long-term single-center experience of defibrillator therapy in children and adolescents.
Frommeyer, Gerrit; Feder, Sebastian; Bettin, Markus; Debus, Volker; Köbe, Julia; Reinke, Florian; Uebing, Anselm; Eckardt, Lars; Kehl, Hans Gerd
2018-06-01
Implantable cardioverter-defibrillator (ICD) systems are established therapy for prevention of sudden cardiac death. Long-term data on ICD systems in children and adolescents is rare. The present study displays a long-term single-center follow-up of children and adolescents with ICD systems. The present study represents a single-center experience of patients younger than 18 years who received an ICD (n = 58). Follow-up data included in-house follow-up as well as examinations of collaborating specialists. Mean age at implantation was 14.0 ± 3.3 years and 33 patients (56.9%) were male. A transvenous ICD system was implanted in 54 patients (93.1%). In 33 patients (56.9%) electrical heart disease or idiopathic ventricular fibrillation represented the underlying condition of ICD implantation. Median follow-up duration was 70 months (45; 94). 3 patients (5.2%) died during the observation period. None of these deaths was associated with ICD failure. Appropriate shocks occurred in 32 patients (55.2%). Inappropriate shock delivery was recorded in 17 patients (29.3%). Supraventricular tachycardia represented the most frequent cause of inappropriate shock delivery (9 patients, 52.9%). T-wave oversensing led to inappropriate shock delivery in 3 patients (17.6%). In 5 patients (29.4%), lead failure caused inappropriate shock delivery. Of note, during follow-up lead failure was reported in 15 patients (25.9%) leading to surgical revision. ICD therapy in children and adolescents is effective for prevention of sudden cardiac death. The rate of appropriate shock deliveries was significantly higher as compared with large ICD trials. Inappropriate therapies occurred frequently. In particular supraventricular tachycardia, T-wave oversensing and lead failures were responsible for these episodes. Copyright © 2017 Elsevier B.V. All rights reserved.
Characterizing cardiac arrest in children undergoing cardiac surgery: A single-center study.
Gupta, Punkaj; Wilcox, Andrew; Noel, Tommy R; Gossett, Jeffrey M; Rockett, Stephanie R; Eble, Brian K; Rettiganti, Mallikarjuna
2017-02-01
To characterize cardiac arrest in children undergoing cardiac surgery using single-center data from the Society of Thoracic Surgeons and Pediatric Advanced Life Support Utstein-Style Guidelines. Patients aged 18 years or less having a cardiac arrest for 1 minute or more during the same hospital stay as heart operation qualified for inclusion (2002-2014). Patients having a cardiac arrest both before or after heart operation were included. Heart operations were classified on the basis of the first cardiovascular operation of each hospital admission (the index operation). The primary outcome was survival to hospital discharge. A total of 3437 children undergoing at least 1 heart operation were included. Overall rate of cardiac arrest among these patients was 4.5% (n = 154) with survival to hospital discharge of 84 patients (66.6%). Presurgery cardiac arrest was noted among 28 patients, with survival of 21 patients (75%). Among the 126 patients with postsurgery cardiac arrest, survival was noted among 84 patients (66.6%). Regardless of surgical case complexity, the median days between heart operation and cardiac arrest, duration of cardiac arrest, and survival after cardiac arrest were similar. The independent risk factors associated with improved chances of survival included shorter duration of cardiac arrest (odds ratio, 1.12; 95% confidence interval, 1.05-1.20; P = .01) and use of defibrillator (odds ratio, 4.51; 95% confidence interval, 1.08-18.87; P = .03). This single-center study demonstrates that characterizing cardiac arrest in children undergoing cardiac surgery using definitions from 2 societies helps to increase data granularity and understand the relationship between cardiac arrest and heart operation in a better way. Copyright © 2016 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.
Preston, Richard A; Karim, Aziz; Dudkowski, Caroline; Zhao, Zhen; Garg, Dyal; Lenz, Oliver; Sica, Domenic A
2013-05-01
Azilsartan medoxomil (AZL-M) is a potent angiotensin II receptor blocker that decreases blood pressure in a dose-dependent manner. It is a pro-drug and not detected in blood after oral administration because of rapid hydrolysis to the active moiety, azilsartan (AZL). AZL undergoes further metabolism to the major metabolite M-II and minor metabolites. The objective of this study was to determine the effect of renal impairment on the pharmacokinetics of AZL and its major metabolite. This was a single-center, open-label, phase I parallel-group study which examined the single-dose (40-mg) pharmacokinetics of AZL and M-II in 24 subjects with mild, moderate, or severe renal impairment or end-stage renal disease requiring hemodialysis (n = 6 per group), respectively, and healthy matched subjects (n = 24). Renal impairment/disease did not cause clinically meaningful increases in exposure to AZL. M-II exposure was higher in all renally impaired subjects and highest in those with severe impairment (approx fivefold higher vs. control). M-II is pharmacologically inactive; increased exposure was not considered important in dose selection for AZL-M in subjects with renal impairment. Hemodialysis did not significantly remove AZL or M-II. Renal impairment had no clinically meaningful effect on the plasma protein binding of AZL or M-II. Single doses of AZL-M 40 mg were well tolerated in all subject groups. Based on the pharmacokinetic and tolerability findings, no dose adjustment of AZL-M is required for subjects with any degree of renal impairment, including end-stage renal disease.
Trade Study of Multiple Thruster Options for the Mars Airplane Concept
NASA Technical Reports Server (NTRS)
Kuhl, Christopher A.; Gayle, Steven W.; Hunter, Craig A.; Kenney, Patrick S.; Scola, Salvatore; Paddock, David A.; Wright, Henry S.; Gasbarre, Joseph F.
2009-01-01
A trade study was performed at NASA Langley Research Center under the Planetary Airplane Risk Reduction (PARR) project (2004-2005) to examine the option of using multiple, smaller thrusters in place of a single large thruster on the Mars airplane concept with the goal to reduce overall cost, schedule, and technical risk. The 5-lbf (22N) thruster is a common reaction control thruster on many satellites. Thousands of these types of thrusters have been built and flown on numerous programs, including MILSTAR and Intelsat VI. This study has examined the use of three 22N thrusters for the Mars airplane propulsion system and compared the results to those of the baseline single thruster system.
Teuscher, Nathan S; Kelley, Richard J; Dumas, Emily O; Klein, Cheri Enders; Awni, Walid M; Meyer, Colin J
2014-07-01
This study investigated the effect of food on the plasma pharmacokinetics of bardoxolone methyl, an antioxidant inflammation modulator, at a 20 mg dose, and the dose proportionality of bardoxolone methyl pharmacokinetics from 20 to 80 mg. It was a single-dose study conducted at a single center in 32 healthy volunteers aged 18-45 years using an amorphous spray-dried dispersion formulation of bardoxolone methyl. In Part A, 16 subjects received single 20 mg doses of bardoxolone methyl under fasting and non-fasting conditions. In Part B, 16 subjects received a single 60 or 80 mg dose of bardoxolone methyl and a matching placebo dose under fasting conditions. Blood samples for pharmacokinetic analysis were taken over 120 hours following dose administration. Single dose administration of 20, 60, and 80 mg bardoxolone methyl was safe and well-tolerated in healthy volunteers. Total bardoxolone methyl exposure was unchanged in the presence of food. However, doses of bardoxolone methyl above 20 mg appear to have a saturated dissolution or absorption process and are associated with less than proportional increases in drug exposure. © 2013, The American College of Clinical Pharmacology.
Vasopressor use following traumatic injury - A single center retrospective study.
Hylands, Mathieu; Godbout, Marie-Pier; Mayer, Sandeep K; Fraser, William D; Vanasse, Alain; Leclair, Marc-André; Turgeon, Alexis F; Lauzier, François; Charbonney, Emmanuel; Trottier, Vincent; Razek, Tarek S; Roy, André; D'Aragon, Frédérick; Belley-Côté, Emilie; Day, Andrew G; Le Guillan, Soazig; Sabbagh, Robert; Lamontagne, François
2017-01-01
Vasopressors are not recommended by current trauma guidelines, but recent reports indicate that they are commonly used. We aimed to describe the early hemodynamic management of trauma patients outside densely populated urban centers. We conducted a single-center retrospective cohort study in a Canadian regional trauma center. All adult patients treated for traumatic injury in 2013 who died within 24 hours of admission or were transferred to the intensive care unit were included. A systolic blood pressure <90 mmHg, a mean arterial pressure <60 mmHg, the use of vasopressors or ≥2 L of intravenous fluids defined hemodynamic instability. Main outcome measures were use of intravenous fluids and vasopressors prior to surgical or endovascular management. Of 111 eligible patients, 63 met our criteria for hemodynamic instability. Of these, 60 (95%) had sustained blunt injury and 22 (35%) had concomitant severe traumatic brain injury. The subgroup of patients referred from a primary or secondary hospital (20 of 63, 32%) had significantly longer transport times (243 vs. 61 min, p<0.01). Vasopressors, used in 26 patients (41%), were independently associated with severe traumatic brain injury (odds ratio 10.2, 95% CI 2.7-38.5). In this cohort, most trauma patients had suffered multiple blunt injuries. Patients were likely to receive vasopressors during the early phase of trauma care, particularly if they exhibited signs of neurologic injury. While these results may be context-specific, determining the risk-benefit trade-offs of fluid resuscitation, vasopressors and permissive hypotension in specific patients subgroups constitutes a priority for trauma research going forwards.
Vasopressor use following traumatic injury – A single center retrospective study
Hylands, Mathieu; Godbout, Marie-Pier; Mayer, Sandeep K.; Fraser, William D.; Vanasse, Alain; Leclair, Marc-André; Turgeon, Alexis F.; Lauzier, François; Charbonney, Emmanuel; Trottier, Vincent; Razek, Tarek S.; Roy, André; D’Aragon, Frédérick; Belley-Côté, Emilie; Day, Andrew G.; Le Guillan, Soazig; Sabbagh, Robert
2017-01-01
Objectives Vasopressors are not recommended by current trauma guidelines, but recent reports indicate that they are commonly used. We aimed to describe the early hemodynamic management of trauma patients outside densely populated urban centers. Methods We conducted a single-center retrospective cohort study in a Canadian regional trauma center. All adult patients treated for traumatic injury in 2013 who died within 24 hours of admission or were transferred to the intensive care unit were included. A systolic blood pressure <90 mmHg, a mean arterial pressure <60 mmHg, the use of vasopressors or ≥2 L of intravenous fluids defined hemodynamic instability. Main outcome measures were use of intravenous fluids and vasopressors prior to surgical or endovascular management. Results Of 111 eligible patients, 63 met our criteria for hemodynamic instability. Of these, 60 (95%) had sustained blunt injury and 22 (35%) had concomitant severe traumatic brain injury. The subgroup of patients referred from a primary or secondary hospital (20 of 63, 32%) had significantly longer transport times (243 vs. 61 min, p<0.01). Vasopressors, used in 26 patients (41%), were independently associated with severe traumatic brain injury (odds ratio 10.2, 95% CI 2.7–38.5). Conclusions In this cohort, most trauma patients had suffered multiple blunt injuries. Patients were likely to receive vasopressors during the early phase of trauma care, particularly if they exhibited signs of neurologic injury. While these results may be context-specific, determining the risk-benefit trade-offs of fluid resuscitation, vasopressors and permissive hypotension in specific patients subgroups constitutes a priority for trauma research going forwards. PMID:28448605
Single-Center Experience With Venovenous ECMO for Influenza-Related ARDS.
Buchner, Jessica; Mazzeffi, Michael; Kon, Zachary; Menaker, Jay; Rubinson, Lewis; Bittle, Gregory; Pasrija, Chetan; Herr, Daniel
2018-06-01
This study was designed to determine whether venovenous extracorporeal membrane oxygenation (VV ECMO) reduced mortality in patients with influenza-related acute respiratory distress syndrome (ARDS). A retrospective cohort study was performed. Baseline characteristics of participants were compared and Kaplan-Meier survival analysis was used to compare survival at last medical center follow-up. Cox proportional hazards modeling also was performed to test for univariate associations between salient variables and mortality. A single-center ECMO referral university hospital. All patients admitted with influenza-related ARDS during the 2015 to 2016 influenza season. Mechanical ventilation alone versus mechanical ventilation and ECMO cannulation. A total of 26 patients with influenza-related ARDS were included in the cohort. Thirteen patients were treated with VV ECMO while 13 were not. Twelve of the ECMO patients and 8 of the non-ECMO patients were transferred from outside hospitals. Patients treated with ECMO were younger and had less hypertension and diabetes mellitus. There was no difference in baseline sequential organ failure assessment score between the 2 groups. In-hospital mortality for ECMO patients was 15.4% versus 46.7% for patients not treated with ECMO. Survival at last medical center follow-up was better in patients treated with ECMO (p = 0.02). Age, highest blood carbon dioxide level, and treatment without ECMO were all associated with increased mortality. Influenza-related ARDS has a high mortality rate and patients treated only with mechanical ventilation have worse outcome than those managed with VV ECMO. More liberal use of ECMO should be considered in patients with influenza-related ARDS. Copyright © 2017 Elsevier Inc. All rights reserved.
Wong, Janice L.; Higgins, Robert F.; Bhowmick, Indrani; Cao, David Xi; Szigethy, Géza; Ziller, Joseph W.
2016-01-01
A new bimetallic platform comprising a six-coordinate Fe(ONO)2 unit bound to an (ONO)M (M = Fe, Zn) has been discovered ((ONOcat)H3 = bis(3,5-di-tert-butyl-2-phenol)amine). Reaction of Fe(ONO)2 with either (ONOcat)Fe(py)3 or with (ONOq)FeCl2 under reducing conditions led to the formation of the bimetallic complex Fe2(ONO)3, which includes unique five- and six-coordinate iron centers. Similarly, the reaction of Fe(ONO)2 with the new synthon (ONOsq˙)Zn(py)2 led to the formation of the heterobimetallic complex FeZn(ONO)3, with a six-coordinate iron center and a five-coordinate zinc center. Both bimetallic complexes were characterized by single-crystal X-ray diffraction studies, solid-state magnetic measurements, and multiple spectroscopic techniques. The magnetic data for FeZn(ONO)3 are consistent with a ground state S = 3/2 spin system, generated from a high-spin iron(ii) center that is antiferromagnetically coupled to a single (ONOsq˙)2– radical ligand. In the case of Fe2(ONO)3, the magnetic data revealed a ground state S = 7/2 spin system arising from the interactions of one high-spin iron(ii) center, one high-spin iron(iii) center, and two (ONOsq˙)2– radical ligands. PMID:28808535
Impact verification of space suit design for space station
NASA Technical Reports Server (NTRS)
Fish, Richard H.
1987-01-01
The ballistic limits of single sheet and double sheet structures made of 6061 T6 Aluminum of 1.8 mm and larger nominal thickness were investigated for projectiles of 1.5 mm diameter fired in the Vertical Gun Range Test Facility and NASA Ames Research Center. The hole diameters and sheet deformation behavior were studied for various ratios of sheet spacing to projectile diameter. The results indicate that for projectiles of less than 1.5 mm diameter the ballistic limit exceeds the nominal 10 km/sec orbital debris encounter velocity, if a single-sheet suit of 1.8 mm thickness is behind a single bumper sheet of 1 mm thickness spaced 12.5 mm apart.
Single-Crystal Diamond Nanobeam Waveguide Optomechanics
NASA Astrophysics Data System (ADS)
Khanaliloo, Behzad; Jayakumar, Harishankar; Hryciw, Aaron C.; Lake, David P.; Kaviani, Hamidreza; Barclay, Paul E.
2015-10-01
Single-crystal diamond optomechanical devices have the potential to enable fundamental studies and technologies coupling mechanical vibrations to both light and electronic quantum systems. Here, we demonstrate a single-crystal diamond optomechanical system and show that it allows excitation of diamond mechanical resonances into self-oscillations with amplitude >200 nm . The resulting internal stress field is predicted to allow driving of electron spin transitions of diamond nitrogen-vacancy centers. The mechanical resonances have a quality factor >7 ×105 and can be tuned via nonlinear frequency renormalization, while the optomechanical interface has a 150 nm bandwidth and 9.5 fm /√{Hz } sensitivity. In combination, these features make this system a promising platform for interfacing light, nanomechanics, and electron spins.
Pancreaticoduodenectomy in a Latin American country: the transition to a high-volume center.
Chan, Carlos; Franssen, Bernardo; Rubio, Alethia; Uscanga, Luis
2008-03-01
To analyze data in a single institution series of pancreaticoduodenectomies (PD) performed in a 7-year period after the transition to a high-volume center for pancreatic surgery. PD has developed dramatically in the last century. Mortality is minimal yet complications are still frequent (around 40%). There are very few reports of PD in Latin America. Data on all PDs performed by a single surgeon from March 2000 to July 2006 in our institution were collected prospectively. During the study's time frame 122 PDs were performed; 84% were classical resections. Mean age was 57.9 years. Of the patients, 51% were female. Intraoperative mean values included blood loss 881 ml, operative time 5 h and 35 min, and vein resection in 14 cases. Both ampullary and pancreatic cancer accounted for 34% of cases (42 patients each), 5.7% were distal bile duct and 4% duodenal carcinomas. Benign pathology included chronic pancreatitis, neuroendocrine tumors, cystic lesions, and other miscellaneous tumors. Overall operative mortality was 6.5% in the 7-year period, 2.2% in the later 5 years. There was a total of 75 consecutive PDs without mortality. Of the patients, 41.8% had one or more complications. Mean survival for pancreatic cancer was 22.6 months and ampullary adenocarcinoma was 31.4 months. To our knowledge, this is the largest single surgeon series of PD performed in Latin America. It emphasizes the importance of experience and expertise at high-volume centers in developing countries.
Five-Year Experience of an Inpatient Palliative Care Unit at an Academic Referral Center.
Shinall, Myrick C; Martin, Sara F; Nelson, Jill; Miller, Richard S; Semler, Matthew W; Zimmerman, Eli E; Noblit, Christy C; Ely, E Wesley; Karlekar, Mohana
2018-01-01
Palliative care units (PCUs) staffed by specialty-trained physicians and nurses have been established in a number of medical centers. The purpose of this study is to review the 5-year experience of a PCU at a large, urban academic referral center. We retrospectively reviewed a prospectively collected database of all admissions to the PCU at Vanderbilt University Medical Center in the first 5 years of its existence, from 2012 through 2017. Over these 5 years, there were 3321 admissions to the PCU. No single underlying disease process accounted for the majority of the patients, but the largest single category of patients were those with malignancy, who accounted for 38% of admissions. Transfers from the intensive care unit accounted for 50% of admissions, with 43% of admissions from a hospital floor and 7% coming from the emergency department or a clinic. Median length of stay in the PCU was 3 days. In hospital deaths occurred for 50% of admitted patients, while 38% of patients were discharged from the PCU to hospice. These data show that a successful PCU is enabled by buy in from a wide variety of referring specialists and by a multidisciplinary palliative care team focused on care of the actively dying patient as well as pain and symptom management, advance care planning, and hospice referral since a large proportion of referred patients do not die in house.
New library buildings: the Health Sciences Library, Memorial University of Newfoundland, St. John's.
Fredericksen, R B
1979-01-01
The new Health Sciences Library of Memorial University of Newfoundland is described and illustrated. A library facility that forms part of a larger health sciences center, this is a medium-sized academic health sciences library built on a single level. Along with a physical description of the library and its features, the concepts of single-level libraries, phased occupancy, and the project management approach to building a large health center library are discussed in detail. Images PMID:476319
NASA Technical Reports Server (NTRS)
Lee, Katharine K.; Davis, Thomas J.; Levin, Kerry M.; Rowe, Dennis W.
2001-01-01
The Traffic Management Advisor (TMA) is a decision-support tool for traffic managers and air traffic controllers that provides traffic flow visualization and other flow management tools. TMA creates an efficiently sequenced and safely spaced schedule for arrival traffic that meets but does not exceed specified airspace system constraints. TMA is being deployed at selected facilities throughout the National Airspace System in the US as part of the FAA's Free Flight Phase 1 program. TMA development and testing, and its current deployment, focuses on managing the arrival capacity for single major airports within single terminal areas and single en route centers. The next phase of development for this technology is the expansion of the TMA capability to complex facilities in which a terminal area or airport is fed by multiple en route centers, thus creating a multicenter TMA functionality. The focus of the multi-center TMA (McTMA) development is on the busy facilities in the Northeast comdor of the US. This paper describes the planning and development of McTMA and the challenges associated with adapting a successful traffic flow management tool for a very complex airspace.
Trim drag reduction concepts for horizontal takeoff single-stage-to-Orbit vehicles
NASA Technical Reports Server (NTRS)
Shaughnessy, John D.; Gregory, Irene M.
1991-01-01
The results of a study to investigate concepts for minimizing trim drag of horizontal takeoff single-stage-to-orbit (SSTO) vehicles are presented. A generic hypersonic airbreathing conical configuration was used as the subject aircraft. The investigation indicates that extreme forward migration of the aerodynamic center as the vehicle accelerates to orbital velocities causes severe aerodynamic instability and trim moments that must be counteracted. Adequate stability can be provided by active control of elevons and rudder, but use of elevons to produce trim moments results in excessive trim drag and fuel consumption. To alleviate this problem, two solution concepts are examined. Active control of the center of gravity (COG) location to track the aerodynamic center decreases trim moment requirements, reduces elevon deflections, and leads to significant fuel savings. Active control of the direction of the thrust vector produces required trim moments, reduces elevon deflections, and also results in significant fuel savings. It is concluded that the combination of active flight control to provide stabilization, (COG) position control to minimize trim moment requirements, and thrust vectoring to generate required trim moments has the potential to significantly reduce fuel consumption during ascent to orbit of horizontal takeoff SSTO vehicles.
Size-dependent plastic deformation of twinned nanopillars in body-centered cubic tungsten
NASA Astrophysics Data System (ADS)
Xu, Shuozhi; Startt, Jacob K.; Payne, Thomas G.; Deo, Chaitanya S.; McDowell, David L.
2017-05-01
Compared with face-centered cubic metals, twinned nanopillars in body-centered cubic (BCC) systems are much less explored partly due to the more complicated plastic deformation behavior and a lack of reliable interatomic potentials for the latter. In this paper, the fault energies predicted by two semi-empirical interatomic potentials in BCC tungsten (W) are first benchmarked against density functional theory calculations. Then, the more accurate potential is employed in large scale molecular dynamics simulations of tensile and compressive loading of twinned nanopillars in BCC W with different cross sectional shapes and sizes. A single crystal, a twinned crystal, and single crystalline nanopillars are also studied as references. Analyses of the stress-strain response and defect nucleation reveal a strong tension-compression asymmetry and a weak pillar size dependence in the yield strength. Under both tensile and compressive loading, plastic deformation in the twinned nanopillars is dominated by dislocation slip on {110} planes that are nucleated from the intersections between the twin boundary and the pillar surface. It is also found that the cross sectional shape of nanopillars affects the strength and the initial site of defect nucleation but not the overall stress-strain response and plastic deformation behavior.
Madden, Jeremy T.; Toth, Scott J.; Dettmar, Christopher M.; Newman, Justin A.; Oglesbee, Robert A.; Hedderich, Hartmut G.; Everly, R. Michael; Becker, Michael; Ronau, Judith A.; Buchanan, Susan K.; Cherezov, Vadim; Morrow, Marie E.; Xu, Shenglan; Ferguson, Dale; Makarov, Oleg; Das, Chittaranjan; Fischetti, Robert; Simpson, Garth J.
2013-01-01
Nonlinear optical (NLO) instrumentation has been integrated with synchrotron X-ray diffraction (XRD) for combined single-platform analysis, initially targeting applications for automated crystal centering. Second-harmonic-generation microscopy and two-photon-excited ultraviolet fluorescence microscopy were evaluated for crystal detection and assessed by X-ray raster scanning. Two optical designs were constructed and characterized; one positioned downstream of the sample and one integrated into the upstream optical path of the diffractometer. Both instruments enabled protein crystal identification with integration times between 80 and 150 µs per pixel, representing a ∼103–104-fold reduction in the per-pixel exposure time relative to X-ray raster scanning. Quantitative centering and analysis of phenylalanine hydroxylase from Chromobacterium violaceum cPAH, Trichinella spiralis deubiquitinating enzyme TsUCH37, human κ-opioid receptor complex kOR-T4L produced in lipidic cubic phase (LCP), intimin prepared in LCP, and α-cellulose samples were performed by collecting multiple NLO images. The crystalline samples were characterized by single-crystal diffraction patterns, while α-cellulose was characterized by fiber diffraction. Good agreement was observed between the sample positions identified by NLO and XRD raster measurements for all samples studied. PMID:23765294
MRI evaluation following partial HIFU therapy for localized prostate cancer: A single-center study.
Hoquetis, L; Malavaud, B; Game, X; Beauval, J B; Portalez, D; Soulie, M; Rischmann, P
2016-09-01
To evaluate the value of MRI for surveillance of primary hemi-HIFU therapy for localized PCa in a single-center. Patients with localized prostate cancer were treated with hemi-HIFU from October 2009 to March 2014. All patients performed MRI before focal therapy, the reader was blinded to the treatment. Oncological failure was defined as positive biopsy or biochemical recurrence (Phoenix). Twenty-five patients were treated with hemi-HIFU in one center. The median nadir PSA was 1.45±1.4ng/mL. Prostate volume decreased from 45 cc to 25 cc on MRI findings. At 20 months, none of the patients had histological recurrence. Biochemical-free survival rate was 88%. MRI evaluation had a negative predictive value of 100% on the treated area and 81% on the untreated area. PSAd≥0.1ng/mL(2) was a predictive factor for cancer on untreated area (P=0.042). MRI control at 6 months is a potentially effective evaluation of treated area after hemi-HIFU and may replace randomized biopsies if PSAd<0.1ng/mL(2) during follow-up. 4. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
Mudie, Kurt L; Gupta, Amitabh; Green, Simon; Hobara, Hiroaki; Clothier, Peter J
2017-02-01
This study assessed the agreement between K vert calculated from 4 different methods of estimating vertical displacement of the center of mass (COM) during single-leg hopping. Healthy participants (N = 38) completed a 10-s single-leg hopping effort on a force plate, with 3D motion of the lower limb, pelvis, and trunk captured. Derived variables were calculated for a total of 753 hop cycles using 4 methods, including: double integration of the vertical ground reaction force, law of falling bodies, a marker cluster on the sacrum, and a segmental analysis method. Bland-Altman plots demonstrated that K vert calculated using segmental analysis and double integration methods have a relatively small bias (0.93 kN⋅m -1 ) and 95% limits of agreement (-1.89 to 3.75 kN⋅m -1 ). In contrast, a greater bias was revealed between sacral marker cluster and segmental analysis (-2.32 kN⋅m -1 ), sacral marker cluster and double integration (-3.25 kN⋅m -1 ), and the law of falling bodies compared with all methods (17.26-20.52 kN⋅m -1 ). These findings suggest the segmental analysis and double integration methods can be used interchangeably for the calculation of K vert during single-leg hopping. The authors propose the segmental analysis method to be considered the gold standard for the calculation of K vert during single-leg, on-the-spot hopping.
Infant Neurobehavioral Development
Lester, Barry M.; Miller, Robin J.; Hawes, Katheleen; Salisbury, Amy; Bigsby, Rosemarie; Sullivan, Mary C.; Padbury, James F.
2011-01-01
The trend toward single-room neonatal intensive care units (NICUs) is increasing; however scientific evidence is, at this point, mostly anecdotal. This is a critical time to assess the impact of the single-room NICU on improving medical and neurobehavioral outcomes of the preterm infant. We have developed a theoretical model that may be useful in studying how the change from an open-bay NICU to a single-room NICU could affect infant medical and neurobehavioral outcome. The model identifies mediating factors that are likely to accompany the change to a single-room NICU. These mediating factors include family centered care, developmental care, parenting and family factors, staff behavior and attitudes, and medical practices. Medical outcomes that plan to be measured are sepsis, length of stay, gestational age at discharge, weight gain, illness severity, gestational age at enteral feeding, and necrotizing enterocolitis (NEC). Neurobehavioral outcomes include the NICU Network Neurobehavioral Scale (NNNS) scores, sleep state organization and sleep physiology, infant mother feeding interaction scores, and pain scores. Preliminary findings on the sample of 150 patients in the open-bay NICU showed a “baseline” of effects of family centered care, developmental care, parent satisfaction, maternal depression, and parenting stress on the neurobehavioral outcomes of the newborn. The single-room NICU has the potential to improve the neurobehavioral status of the infant at discharge. Neurobehavioral assessment can assist with early detection and therefore preventative intervention to maximize developmental outcome. We also present an epigenetic model of the potential effects of maternal care on improving infant neurobehavioral status. PMID:21255702
ERIC Educational Resources Information Center
Berson, Janet S.
This study attempts to clarify part of the decision-making process centering around combining family and career. There are two aspects of the study. In the first, perceived costs of combining roles are assessed and evaluated in light of mother's employment history. The subjects in this part of the study were 141 single women and 43 married women.…
Petrinco, Michele; Pagano, Eva; Desideri, Alessandro; Bigi, Riccardo; Ghidina, Marco; Ferrando, Alberto; Cortigiani, Lauro; Merletti, Franco; Gregori, Dario
2009-01-01
Several methodological problems arise when health outcomes and resource utilization are collected at different sites. To avoid misleading conclusions in multi-center economic evaluations the center effect needs to be taken into adequate consideration. The aim of this article is to compare several models, which make use of a different amount of information about the enrolling center. To model the association of total medical costs with the levels of two sets of covariates, one at patient and one at center level, we considered four statistical models, based on the Gamma model in the class of the Generalized Linear Models with a log link, which use different amount of information on the enrolling centers. Models were applied to Cost of Strategies after Myocardial Infarction data, an international randomized trial on costs of uncomplicated acute myocardial infarction (AMI). The simple center effect adjustment based on a single random effect results in a more conservative estimation of the parameters as compared with approaches which make use of deeper information on the centers characteristics. This study shows, with reference to a real multicenter trial, that center information cannot be neglected and should be collected and inserted in the analysis, better in combination with one or more random effect, taking into account in this way also the heterogeneity among centers because of unobserved centers characteristics.
NASA Astrophysics Data System (ADS)
El Harouny, El Hassan; Nakra Mohajer, Soukaina; Ibral, Asmaa; El Khamkhami, Jamal; Assaid, El Mahdi
2018-05-01
Eigenvalues equation of hydrogen-like off-center single donor impurity confined in polarized homogeneous hemispherical quantum dot deposited on a wetting layer, capped by insulated matrix and submitted to external uniform electric field is solved in the framework of the effective mass approximation. An infinitely deep potential is used to describe effects of quantum confinement due to conduction band offsets at surfaces where quantum dot and surrounding materials meet. Single donor ground state total and binding energies in presence of electric field are determined via two-dimensional finite difference approach and Ritz-Hassé variation principle. For the latter method, attractive coulomb correlation between electron and ionized single donor is taken into account in the expression of trial wave function. It appears that off-center single dopant binding energy, spatial extension and radial probability density are strongly dependent on hemisphere radius and single dopant position inside quantum dot. Influence of a uniform electric field is also investigated. It shows that Stark effect appears even for very small size dots and that single dopant energy shift is more significant when the single donor is near hemispherical surface.
NASA Astrophysics Data System (ADS)
Cross, L. E.; Newnham, R. E.; Biggers, J. V.
1984-05-01
This report focuses upon the parts of the Center program which have drawn most extensively upon Navy funds. In the basic study of polarization processes in high K dielectrics, major progress has been made in understanding the mechanisms in relaxor ferroelectric in the perovskite structure families. A new effort is also being mounted to obtain more precise evaluation of the internal stress effects in fine grained barium titanate. Related to reliability, studies of the effects of induced macro-defects are described, and preparation for the evaluation of space charge by internal potential distribution measurements discussed. To develop new processing methods for very thin dielectric layers, a new type of single barrier layer multilayer is discussed, and work on the thermal evaporation of oriented crystalline antimony sulphur iodide describe.
Bray, Kerem; Previdi, Rodolfo; Gibson, Brant C; Shimoni, Olga; Aharonovich, Igor
2015-03-21
Fluorescent nanodiamonds are attracting major attention in the field of bio-sensing and bio-labeling. In this work we demonstrate a robust approach to achieve an encapsulation of individual nanodiamonds with phenol-ionic complexes that enhance the photoluminescence from single nitrogen vacancy (NV) centers. We show that single NV centres in the coated nanodiamonds also exhibit shorter lifetimes, opening another channel for high resolution sensing. We propose that the nanodiamond encapsulation reduces the non-radiative decay pathways of the NV color centers. Our results provide a versatile and assessable way to enhance photoluminescence from nanodiamond defects that can be used in a variety of sensing and imaging applications.
The evolving concept of "patient-centeredness" in patient-physician communication research.
Ishikawa, Hirono; Hashimoto, Hideki; Kiuchi, Takahiro
2013-11-01
Over the past few decades, the concept of "patient-centeredness" has been intensively studied in health communication research on patient-physician interaction. Despite its popularity, this concept has often been criticized for lacking a unified definition and operationalized measurement. This article reviews how health communication research on patient-physician interaction has conceptualized and operationalized patient-centered communication based on four major theoretical perspectives in sociology (i.e., functionalism, conflict theory, utilitarianism, and social constructionism), and discusses the agenda for future research in this field. Each theory addresses different aspects of the patient-physician relationship and communication from different theoretical viewpoints. Patient-centeredness is a multifaceted construct with no single theory that can sufficiently define the whole concept. Different theoretical perspectives of patient-centered communication can be selectively adopted according to the context and nature of problems in the patient-physician relationship that a particular study aims to explore. The present study may provide a useful framework: it offers an overview of the differing models of patient-centered communication and the expected roles and goals in each model; it does so toward identifying a communication model that fits the patient and the context and toward theoretically reconstructing existing measures of patient-centered communication. Furthermore, although patient-centered communication has been defined mainly from the viewpoint of physician's behaviors aimed at achieving patient-centered care, patient competence is also required for patient-centered communication. This needs to be examined in current medical practice. Copyright © 2013 Elsevier Ltd. All rights reserved.
Hall mobility and photoconductivity in TlGaSeS crystals
NASA Astrophysics Data System (ADS)
Qasrawi, A. F.; Gasanly, N. M.
2013-01-01
In this work, the fundamental properties of the TlGaSeS single crystals are investigated by means of temperature dependent electrical resistivity and Hall mobility. The crystal photo-responsibility as function of illumination intensity and temperature is also tested in the temperature range of 350-160 K. The study allowed the determination of acceptor centers as 230 and 450 meV below and above 260 K, and recombination centers as 181, 363, and 10 meV at low, moderate, and high temperatures, respectively. While the temperature-dependent Hall mobility behaved abnormally, the photoconductivity analysis reflected an illumination intensity dependent recombination center. Namely, the recombination center increased from 10 to 90 meV as the light intensity increased from 27.9 to 76.7 mW cm-2, respectively. That strange behavior was attributed to the temporary shift in Fermi level caused by photoexcitation.
ERIC Educational Resources Information Center
Chuck, Jo-Anne
2011-01-01
Science students leaving undergraduate programs are entering the biotechnology industry where they are presented with issues which require integration of science content. Students find this difficult as through-out their studies, most content is limited to a single subdiscipline (e.g., biochemistry, immunology). In addition, students need…
Defining the Difference: Comparing Integrated and Traditional Single-Subject Lessons
ERIC Educational Resources Information Center
Zhbanova, Ksenia S.; Rule, Audrey C.; Montgomery, Sarah E.; Nielsen, Lynn E.
2010-01-01
Early childhood curricula should be authentic and child-centered, however, many teachers still rely on direct instruction lessons. To better define how an integrated curriculum meets the needs of students, this study examined teacher talk and actions during instructional activities with first and second graders under two conditions: (1)…
Camp H.M. Smith and Navy Public Works Center Manana Title ...
Camp H.M. Smith and Navy Public Works Center Manana Title VII (Capehart) Housing, Four-Bedroom, Single-Family Type 10, Birch Circle, Elm Drive, Elm Circle, and Date Drive, Pearl City, Honolulu County, HI
Camp H.M. Smith and Navy Public Works Center Manana Title ...
Camp H.M. Smith and Navy Public Works Center Manana Title VII (Capehart) Housing, Three-Bedroom Single-Family Type 7, Birch Circle, Elm Drive, Elm Circle, and Date Drive, Pearl City, Honolulu County, HI
Camp H.M. Smith and Navy Public Works Center Manana Title ...
Camp H.M. Smith and Navy Public Works Center Manana Title VII (Capehart) Housing, Three-Bedroom Single-Family Type 9, Birch Circle, Elm Drive, Elm Circle, and Date Drive, Pearl City, Honolulu County, HI
Building Literacy Opportunities into Children's Block Play: What Every Teacher Should Know
ERIC Educational Resources Information Center
Wellhousen, Karyn; Giles, Rebecca M.
2005-01-01
Learning centers are a highly regarded and widely accepted practice in early childhood classrooms. Centers offer a variety of experiences during a single time segment that encourage children to explore materials, interact with peers, and accomplish new tasks. In this article, the author presents the block center, a popular mainstay among learning…
Site Planning: Auraria Higher Education Center.
ERIC Educational Resources Information Center
Auraria Higher Education Center, Denver, CO.
This book presents the site master plan for the Auraria Higher Education Center, which is dedicated to the offering of an urban-oriented program in higher education and is made up of three institutions -- the Denver Center of the University of Colorado, Metropolitan State College, and the Community College of Denver located on a single site in the…
The Center for Cancer Research’s ability to rapidly deploy integrated basic and clinical research teams at a single site facilitated the rapid FDA approval of the immunotherapy drug avelumab for metastatic Merkel cell carcinoma, a rare, aggressive form of skin cancer. Learn more...
Marshak Lectureship: Vibrational properties of isolated color centers in diamond
NASA Astrophysics Data System (ADS)
Alkauskas, Audrius
In this talk we review our recent work on first-principles calculations of vibrational properties of isolated defect spin qubits and single photon emitters in diamond. These properties include local vibrational spectra, luminescence lineshapes, and electron-phonon coupling. They are key in understanding physical mechanisms behind spin-selective optical initialization and read-out, quantum efficiency of single-photon emitters, as well as in the experimental identification of as yet unknown centers. We first present the methodology to calculate and analyze vibrational properties of effectively isolated defect centers. We then apply the methodology to the nitrogen-vacancy and the silicon-vacancy centers in diamond. First-principles calculations yield important new insights about these important defects. Work performed in collaboration with M. W. Doherty, A. Gali, E. Londero, L. Razinkovas, and C. G. Van de Walle. Supported by the Research Council of Lithuania (Grant M-ERA.NET-1/2015).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Akturk, Eser S.; Yap, Glenn P. A.; Theopold, Klaus H.
2015-10-16
A chromium(I) dinitrogen complex reacts rapidly with O 2 to form the mononuclear dioxo complex [Tp tBu,MeCr V(O) 2] (Tp tBu,Me=hydrotris(3- tert-butyl-5-methylpyrazolyl)borate), whereas the analogous reaction with sulfur stops at the persulfido complex [Tp tBu,MeCr III(S 2)]. The transformation of the putative peroxo intermediate [Tp tBu,MeCr III(O 2)] (S= 3/ 2) into [Tp tBu,MeCr V(O) 2] (S= 1/ 2) is spin-forbidden. The minimum-energy crossing point for the two potential energy surfaces has been identified. Finally, although the dinuclear complex [(Tp tBu,MeCr) 2(μ-O) 2] exists, mechanistic experiments suggest that O 2 activation occurs on a single metal center, by an oxidativemore » addition on the quartet surface followed by crossover to the doublet surface.« less
Randomly distilling W-class states into general configurations of two-party entanglement
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cui, W.; Chitambar, E.; Lo, H. K.
2011-11-15
In this article we obtain results for the task of converting a single N-qubit W-class state (of the form {radical}(x{sub 0})|00...0>+{radical}(x{sub 1})|10...0>+{center_dot}{center_dot}{center_dot}+{radical}(x{sub N})|00...1>) into maximum entanglement shared between two random parties. Previous studies in random distillation have not considered how the particular choice of target pairs affects the transformation, and here we develop a strategy for distilling into general configurations of target pairs. We completely solve the problem of determining the optimal distillation probability for all three-qubit configurations and most four-qubit configurations when x{sub 0}=0. Our proof involves deriving new entanglement monotones defined on the set of four-qubit W-class states.more » As an additional application of our results, we present new upper bounds for converting a generic W-class state into the standard W state |W{sub N}>={radical}((1/N))(|10...0>+{center_dot}{center_dot}{center_dot}+|00...1>).« less
Effect of bending and vacancies on the conductance of carbon nanotubes
NASA Astrophysics Data System (ADS)
Hansson, Anders; Paulsson, Magnus; Stafström, Sven
2000-09-01
Electron transport through nanotubes is studied theoretically using the Landauer formalism. The studies are carried out for finite metallic nanotubes that bridge two contacts pads. The current is observed to increase stepwise with the applied voltage. Each step corresponds to resonance tunneling including one single-particle eigenstate of the nanotube. Moderate bending of the nanotube results in a shift of the single-particle levels but the overall current remains essentially unaffected. For large bending, however, the π electron system becomes more disturbed, which introduces backscattering and a marked decrease in the conductivity along the tube. A single carbon vacancy in the nanotube is shown to have very small effect on the conductivity in the center of the metallic band whereas, by increasing the defect concentration the conductivity decreases in the same way as for the strongly bent tubes.
Influence of processing conditions on point defects and luminescence centers in ZnO
NASA Astrophysics Data System (ADS)
Zhong, J.; Kitai, A. H.; Mascher, P.
1993-12-01
Positron lifetime spectroscopy and cathodoluminescence were employed to study luminescence centers in ZnO. The samples were high-purity polycrystalline ceramics sintered at temperatures ranging from 800 to 1400 C for 2 to 40 h. Scanning electron microscopy shows that as annealing temperatures and/or times increase, the average grain size increases and can reach 30 micron for samples sintered at 1200 C. At the same time, the positron bulk lifetime approaches theoretically estimated single-crystal values, while the integrated luminescence intensity increase significantly. A further increase of the sintering temperature beyond 1200 C results in a decrease in the luminescence intensity, in good agreement with the only weak luminescence observed in single-crystalline material. The positron lifetime spectra clearly show the existence of the dominant vacancy-type defect, most likely a complex involving V(sub Zn), or the divacancy, V(sub Zn)V(sub O), independent of sample thermal history. The concentration of this center steadily decreases with increasing sintering temperatures. It is concluded that the yellow luminescence centers are related to charged zinc vacancies trapped in the grain boundary regions. We propose that the observed broadness of the spectra likely originates from the modification of the electronic configuration of the luminescence centers due to their complex environment. A direct connection between the positron and the luminescence results could not be established; instead, they appear to reflect two relatively independent aspects of the samples. It could be shown, however, that positron annihilation measurements can be used effectively to monitor the evolution of the microstructure of the samples, in good agreement with scanning electron micrographs.
Effects of a Mixed-Mode Peer Response on Student Response Behavior and Writing Performance
ERIC Educational Resources Information Center
Wang, Jen-Hang; Hsu, Shih-Hsun; Chen, Sherry Y.; Ko, Hwa-Wei; Ku, Yu-Min; Chan, Tak-Wai
2014-01-01
The study proposed a mix-mode peer response, the E-Peer Response (EPR), to overcome the bias of a single mode, and examined how students with different levels of ability react to the EPR. Two classes participated in this study. One was the experimental group (EG) with the EPR; the other was the control group (CG) with a teacher-centered writing…
Hack, Nawaz; Akbar, Umer; Thompson-Avila, Amanda; Fayad, Sarah M; Hastings, Erin M; Moro, Elena; Nestor, Kelsey; Ward, Herbert; York, Michele; Okun, Michael S
2014-01-01
Impulse control disorders (ICDs), dopamine dysregulation syndrome (DDS), and dopamine agonist withdrawal syndrome (DAWS) have been reported commonly in Parkinson's disease (PD) populations. The treatment approaches may be widely variable and there is not much information on these syndromes in the setting of deep brain stimulation (DBS). To evaluate (1) ICDs, DAWS and DDS pre- and post DBS in PD and (2) to investigate pre-DBS treatment strategies regarding these behaviors among Parkinson Study Group (PSG) centers. Forty-eight PSG centers were surveyed on ICDs, DAWS and DDS, as well as on potential relationships to DBS and treatment approaches. Sixty-seven percent of PSG centers reported that they served a population of over 500 PD patients per year, and 94% of centers performed DBS surgery. Most centers (92%) reported screening for ICDs, DAWS and DDS. Of the centers screening for these symptoms, 13% reported always employing a formal battery of pre-operative tests, 46% of sites inconsistently used a formal battery, while 23% of sites reported never using a formal battery to screen for these symptoms. The estimated numbers of centers observing ICDs, DAWS and DDS pre-operatively in individuals with PD were 71%, 69%, and 69%, respectively. PSG DBS centers observing at least one case of a new de novo occurrence of an ICD, DAWS or DDS after DBS surgery were 67%, 65% and 65%, respectively. The results suggest that addiction-like syndromes and withdrawal syndromes are prevalent in expert PSG centers performing DBS. Most centers reported screening for these issues without the use of a formal battery, and there were a large number of centers reporting ICDs, DAWS and DDS post-DBS. A single treatment strategy did not emerge.
Modulation of gene expression as a new skin anti-aging strategy.
Talbourdet, Sylvie; Sadick, Neil S; Lazou, Kristell; Bonnet-Duquennoy, Mathilde; Kurfurst, Robin; Neveu, Michele; Heusèle, Catherine; André, Patrice; Schnebert, Sylvianne; Draelos, Zoe D; Perrier, Eric
2007-06-01
[corrected] The signs of aging may originate from natural processes or from exposure to the sun, wind, or other environmental factors. To evaluate the anti-aging effects of potential agents researchers must first identify and be able to quantify epidermal markers that change with aging. This paper summarizes the results of studies conducted to evaluate the transcriptional effects of an Aframomum angustifolium seed extract and Malva Sylvestris extract, and the antiaging efficacy of a skin care product containing the Aframomum angustifolium seed extract. The transcriptional effect of an Aframomum angustifolium seed extract on normal human keratinocytes (NHKs) and normal human fibroblasts (NHF) was evaluated in vitro with the use of a low-density DNA array technology. The Malva Sylvestris extract was studied with a commercial DNA macroarray and by a real-time quantitative reverse transcriptase-polymerase chain reaction. The in vitro anti-aging activities of the Malva sylvestris extract were compared with those of all-trans retinoic acid (RA), a well-established topical therapy for photodamage and wrinkles. The genes studied were known to be modified by RA. The anti-aging efficacy of a facial skin care product containing Aframomum angustifolium seed extract was evaluated in a single-center study using image processing analysis and in a 2-center study by evaluation of the photographs by the investigator, independent evaluators, and subjects. In general, the Aframomum angustifolium seed extract strongly modified the gene expression profiles of NHKs and weakly modified the gene expression profiles of NHFs. After incubation with Aframomum angustifolium seed extract, the expressions of 3 antioxidant genes (metallothionein 1, metallothionein 2, and thioredoxin) were increased in NHKs, while expressions of 1 antioxidant gene (glutathione peroxidase) was increased in NHFs. Concerning the Malva sylvestris extract, a cDNA macro-array technology experiment with the reconstructed human epidermis model showed that some genes modulated by treatment with the Malva sylvestris extract are also regulated by RA treatment indicating a similar activity at the mRNA level. In the single-center study, a facial skin care product containing the Aframomum angustifolium seed extract significantly improved the homogeneity of the skin. The areas of the detected objects (skin imperfections) decreased significantly on each studied area of the face and the variance decreased significantly over the entire face. In the 2-center study, 28% percent of the subjects reported a greater than 50% overall global improvement in their skin by the end of the study compared to 11% of the subjects after 4 weeks of treatment. Seventy-six percent of subjects said they would purchase the cream. The authors developed a low-density DNA chip method that permitted the study of the transcriptional effect of Malva Sylvestris extract and of Aframomum angustrifolium seed extract. The gene expression profiles obtained demonstrate the anti-aging properties of these compounds. An in vivo single-center study, performed and analyzed with an assay based on image processing analysis, demonstrated the antiwrinkle activity of a formulation containing the Aframomum angustifolium seed extract. The data obtained in the 2-center study suggests that the cosmeceutical containing Aframomum angustifolium seed extract produces a global rejuvenation effect in terms of redness, pigmentation, and fine lines similar to that noted utilizing an intense pulse light source.
Enhanced photoelectric detection of NV magnetic resonances in diamond under dual-beam excitation
NASA Astrophysics Data System (ADS)
Bourgeois, E.; Londero, E.; Buczak, K.; Hruby, J.; Gulka, M.; Balasubramaniam, Y.; Wachter, G.; Stursa, J.; Dobes, K.; Aumayr, F.; Trupke, M.; Gali, A.; Nesladek, M.
2017-01-01
The core issue for the implementation of NV center qubit technology is a sensitive readout of the NV spin state. We present here a detailed theoretical and experimental study of NV center photoionization processes, used as a basis for the design of a dual-beam photoelectric method for the detection of NV magnetic resonances (PDMR). This scheme, based on NV one-photon ionization, is significantly more efficient than the previously reported single-beam excitation scheme. We demonstrate this technique on small ensembles of ˜10 shallow NVs implanted in electronic grade diamond (a relevant material for quantum technology), on which we achieve a cw magnetic resonance contrast of 9%—three times enhanced compared to previous work. The dual-beam PDMR scheme allows independent control of the photoionization rate and spin magnetic resonance contrast. Under a similar excitation, we obtain a significantly higher photocurrent, and thus an improved signal-to-noise ratio, compared to single-beam PDMR. Finally, this scheme is predicted to enhance magnetic resonance contrast in the case of samples with a high proportion of substitutional nitrogen defects, and could therefore enable the photoelectric readout of single NV spins.
Lin, Chia-Wei; Lin, Cheng-Feng; Hsue, Bih-Jen; Su, Fong-Chin
2014-04-01
The purpose of the current study was to evaluate the postural stability of single-leg standing on the retiré position in ballet dancers having three different levels of skill. Nine superior experienced female ballet dancers, 9 experienced, and 12 novice dancers performed single-leg standing in the retiré position. The parameters of center of pressure (COP) in the anterior-posterior and medial-lateral directions and the maximum distance between COP and the center of mass (COM) were measured. The inclination angles of body segments (head, torso, and supporting leg) in the frontal plane were also calculated. The findings showed that the novice dancers had a trend of greater torso inclination angles than the experienced dancers but that the superior experienced dancers had greater maximum COM-COP distance in the anterior-posterior direction. Furthermore, both experienced and novice dancers had better balance when standing on the nondominant leg, whereas the superior experienced dancers had similar postural stability between legs. Based on the findings, ballet training should put equal focus on both legs and frontal plane control (medial-lateral direction) should be integrated to ballet training program.
NASA Technical Reports Server (NTRS)
Abbott, Terence S.; Steinmetz, George G.
1987-01-01
A ground-based aircraft simulation study was conducted to determine the effect on pilot performance of replacing the electromechanical altimeter and airspeed indicators with electronically generated representations integrated into the primary flight display via moving-tape (linear moving scale) formats. Several key factors relating to moving-tape formats were examined during the study: tape centering, secondary (trend) information, and tape orientation. The factor of centering refers to whether the tape was centered about the actual airspeed or altitude or about some defined reference value. Tape orientation refers to whether the values represented are arranged in either descending or ascending order. Six pilots participated in this study, with each subject performing 18 runs along a single, known flight profile. Subjective results indicated that the moving-tape formats were generally better than that of the conventional instruments. They also indicated that an actual-centered fixed pointer was preferred to a reference-centered pointer. Performance data for a visual secondary task showed that formats not containing trend information produced better performance; however, no difference was noted in airspeed tracking or altitude tracking performance. Regarding tape orientation, subjective comments indicated that there was lower work load and better performance when the airspeed tape had the high numbers at the top.
Perceptual-center modeling is affected by including acoustic rate-of-change modulations.
Harsin, C A
1997-02-01
This study investigated the acoustic correlates of perceptual centers (p-centers) in CV and VC syllables and developed an acoustic p-center model. In Part 1, listeners located syllables' p-centers by a method-of-adjustment procedure. The CV syllables contained the consonants /s/,/r/,/n/,/t/,/d/,/k/, and /g/; the VCs, the consonants /s/,/r/, and /n/. The vowel in all syllables was /a/. The results of this experiment replicated and extended previous findings regarding the effects of phonetic variation on p-centers. In Part 2, a digital signal processing procedure was used to acoustically model p-center perception. Each stimulus was passed through a six-band digital filter, and the outputs were processed to derive low-frequency modulation components. These components were weighted according to a perceived modulation magnitude function and recombined to create six psychoacoustic envelopes containing modulation energies from 3 to 47 Hz. In this analysis, p-centers were found to be highly correlated with the time-weighted function of the rate-of-change in the psychoacoustic envelopes, multiplied by the psychoacoustic envelope magnitude increment. The results were interpreted as suggesting (1) the probable role of low-frequency energy modulations in p-center perception, and (2) the presence of perceptual processes that integrate multiple articulatory events into a single syllabic event.
Unique life sciences research facilities at NASA Ames Research Center
NASA Technical Reports Server (NTRS)
Mulenburg, G. M.; Vasques, M.; Caldwell, W. F.; Tucker, J.
1994-01-01
The Life Science Division at NASA's Ames Research Center has a suite of specialized facilities that enable scientists to study the effects of gravity on living systems. This paper describes some of these facilities and their use in research. Seven centrifuges, each with its own unique abilities, allow testing of a variety of parameters on test subjects ranging from single cells through hardware to humans. The Vestibular Research Facility allows the study of both centrifugation and linear acceleration on animals and humans. The Biocomputation Center uses computers for 3D reconstruction of physiological systems, and interactive research tools for virtual reality modeling. Psycophysiological, cardiovascular, exercise physiology, and biomechanical studies are conducted in the 12 bed Human Research Facility and samples are analyzed in the certified Central Clinical Laboratory and other laboratories at Ames. Human bedrest, water immersion and lower body negative pressure equipment are also available to study physiological changes associated with weightlessness. These and other weightlessness models are used in specialized laboratories for the study of basic physiological mechanisms, metabolism and cell biology. Visual-motor performance, perception, and adaptation are studied using ground-based models as well as short term weightlessness experiments (parabolic flights). The unique combination of Life Science research facilities, laboratories, and equipment at Ames Research Center are described in detail in relation to their research contributions.
Diamond like carbon coatings: Categorization by atomic number density
NASA Technical Reports Server (NTRS)
Angus, John C.
1986-01-01
Dense diamond-like hydrocarbon films grown at the NASA Lewis Research Center by radio frequency self bias discharge and by direct ion beam deposition were studied. A new method for categorizing hydrocarbons based on their atomic number density and elemental composition was developed and applied to the diamond-like hydrocarbon films. It was shown that the diamond-like hydrocarbon films are an entirely new class of hydrocarbons with atomic number densities lying between those of single crystal diamond and adamantanes. In addition, a major review article on these new materials was completed in cooperation with NASA Lewis Research Center personnel.
Observations and analysis of lunar radio emission at 3.09 mm wavelength
NASA Technical Reports Server (NTRS)
Ulich, B. L.; Cogdell, J. R.; Davis, J. H.; Calvert, T. A.
1974-01-01
An analysis of data on lunar radio emission at 3.09 mm wavelength is presented. The data were obtained during a single lunation in a manner that facilitates their comparison with a calculated model. Specific regions of the moon (Copernicus, Sea of Serenity, Sea of Tranquillity, Ocean of Storms, and an highland region near the mean center) were studied with enough angular resolution to distinguish between different types of terrain. The data were absolutely calibrated and yield a new measurement of the lunation average brightness temperature of the center of the moon.
Wongcharoen, Suleeporn; Sungkarat, Somporn; Munkhetvit, Peeraya; Lugade, Vipul; Silsupadol, Patima
2017-02-01
The purpose of this study was to compare the efficacy of four different home-based interventions on dual-task balance performance and to determine the generalizability of the four trainings to untrained tasks. Sixty older adults, aged 65 and older, were randomly assigned to one of four home-based interventions: single-task motor training, single-task cognitive training, dual-task motor-cognitive training, and dual-task cognitive-cognitive training. Participants received 60-min individualized training sessions, 3 times a week for 4 weeks. Prior to and following the training program, participants were asked to walk under two single-task conditions (i.e. narrow walking and obstacle crossing) and two dual-task conditions (i.e. a trained narrow walking while performing verbal fluency task and an untrained obstacle crossing while counting backward by 3s task). A nine-camera motion capture system was used to collect the trajectories of 32 reflective markers placed on bony landmarks of participants. Three-dimensional kinematics of the whole body center of mass and base of support were computed. Results from the extrapolated center of mass displacement indicated that motor-cognitive training was more effective than the single-task motor training to improve dual-task balance performance (p=0.04, ES=0.11). Interestingly, balance performance under both single-task and dual-task conditions can also be improved through a non-motor, single-task cognitive training program (p=0.01, ES=0.13, and p=0.01, ES=0.11, respectively). However, improved dual-task processing skills during training were not transferred to the novel dual task (p=0.15, ES=0.09). This is the first study demonstrating that home-based dual-task training can be effectively implemented to improve balance performance during gait in older adults. Copyright © 2016 Elsevier B.V. All rights reserved.
Single-leg squats can predict leg alignment in dancers performing ballet movements in "turnout".
Hopper, Luke S; Sato, Nahoko; Weidemann, Andries L
2016-01-01
The physical assessments used in dance injury surveillance programs are often adapted from the sports and exercise domain. Bespoke physical assessments may be required for dance, particularly when ballet movements involve "turning out" or external rotation of the legs beyond that typically used in sports. This study evaluated the ability of the traditional single-leg squat to predict the leg alignment of dancers performing ballet movements with turnout. Three-dimensional kinematic data of dancers performing the single-leg squat and five ballet movements were recorded and analyzed. Reduction of the three-dimensional data into a one-dimensional variable incorporating the ankle, knee, and hip joint center positions provided the strongest predictive model between the single-leg squat and the ballet movements. The single-leg squat can predict leg alignment in dancers performing ballet movements, even in "turned out" postures. Clinicians should pay careful attention to observational positioning and rating criteria when assessing dancers performing the single-leg squat.
Single-leg squats can predict leg alignment in dancers performing ballet movements in “turnout”
Hopper, Luke S; Sato, Nahoko; Weidemann, Andries L
2016-01-01
The physical assessments used in dance injury surveillance programs are often adapted from the sports and exercise domain. Bespoke physical assessments may be required for dance, particularly when ballet movements involve “turning out” or external rotation of the legs beyond that typically used in sports. This study evaluated the ability of the traditional single-leg squat to predict the leg alignment of dancers performing ballet movements with turnout. Three-dimensional kinematic data of dancers performing the single-leg squat and five ballet movements were recorded and analyzed. Reduction of the three-dimensional data into a one-dimensional variable incorporating the ankle, knee, and hip joint center positions provided the strongest predictive model between the single-leg squat and the ballet movements. The single-leg squat can predict leg alignment in dancers performing ballet movements, even in “turned out” postures. Clinicians should pay careful attention to observational positioning and rating criteria when assessing dancers performing the single-leg squat. PMID:27895518
Wagner, Mathilde; Corcuera-Solano, Idoia; Lo, Grace; Esses, Steven; Liao, Joseph; Besa, Cecilia; Chen, Nelson; Abraham, Ginu; Fung, Maggie; Babb, James S; Ehman, Richard L; Taouli, Bachir
2017-08-01
Purpose To assess the determinants of technical failure of magnetic resonance (MR) elastography of the liver in a large single-center study. Materials and Methods This retrospective study was approved by the institutional review board. Seven hundred eighty-one MR elastography examinations performed in 691 consecutive patients (mean age, 58 years; male patients, 434 [62.8%]) in a single center between June 2013 and August 2014 were retrospectively evaluated. MR elastography was performed at 3.0 T (n = 443) or 1.5 T (n = 338) by using a gradient-recalled-echo pulse sequence. MR elastography and anatomic image analysis were performed by two observers. Additional observers measured liver T2* and fat fraction. Technical failure was defined as no pixel value with a confidence index higher than 95% and/or no apparent shear waves imaged. Logistic regression analysis was performed to assess potential predictive factors of technical failure of MR elastography. Results The technical failure rate of MR elastography at 1.5 T was 3.5% (12 of 338), while it was higher, 15.3% (68 of 443), at 3.0 T. On the basis of univariate analysis, body mass index, liver iron deposition, massive ascites, use of 3.0 T, presence of cirrhosis, and alcoholic liver disease were all significantly associated with failure of MR elastography (P < .004); but on the basis of multivariable analysis, only body mass index, liver iron deposition, massive ascites, and use of 3.0 T were significantly associated with failure of MR elastography (P < .004). Conclusion The technical failure rate of MR elastography with a gradient-recalled-echo pulse sequence was low at 1.5 T but substantially higher at 3.0 T. Massive ascites, iron deposition, and high body mass index were additional independent factors associated with failure of MR elastography of the liver with a two-dimensional gradient-recalled-echo pulse sequence. © RSNA, 2017.
Edinburgh, Laurel; Pape-Blabolil, Julie; Harpin, Scott B.; Saewyc, Elizabeth
2015-01-01
The aim of this study was to describe contextual events, abuse experiences, and disclosure processes of adolescents who presented to a hospital-based Child Advocacy Center for medical evaluation and evidentiary collection as indicated after experiencing multiple perpetrator rape during a single event (n = 32) and to compare these findings to a group of single perpetrator sexual assaults (n = 534). This study used a retrospective mixed-methods design with in-depth, forensic interviews and complete physical examinations of gang-raped adolescents. Patients ranged from 12 to 17 years (M = 14 years). Girls who experienced multiple perpetrator rape during a single event were more likely to have run away, to have drunk alcohol in the past month, and to have participated in binge drinking in the past 2 weeks. Acute presentation of these victims were rare but 30% had hymenal transections and 38% had sexually transmitted infections (STIs). Forensic interviews revealed alcohol was a common weapon used by offenders, and its use resulted in victims experiencing difficulty in remembering and reporting details for police investigation or physical and mental health care. Most victims were raped at parties they attended with people they thought they could trust, and they felt let down by witnesses who could have helped but did not intervene. Although relatively rare, multiple perpetrator rape during a single event is a type of severe sexual assault experience and has significant risks for deleterious health outcomes. These victims require health care by trained providers to diagnose physical findings, treat STIs, screen for trauma, and support victims. PMID:24933707
Dudkowski, Caroline; Karim, Aziz; Zhao, Zhen; Alonso, Alberto B; Garg, Dyal; Preston, Richard A
2018-01-01
Azilsartan medoxomil (AZL-M) is a potent angiotensin II receptor blocker that decreases blood pressure in a dose-dependent manner. It is a prodrug that is not detected in blood after its oral administration because of its rapid hydrolysis to the active moiety, azilsartan (AZL). AZL undergoes further metabolism to the major metabolite, M-II, and minor metabolites. The objective of this study was to determine the effect of mild to moderate hepatic impairment on the pharmacokinetics of AZL and its major metabolite. This was a single-center, open-label, phase 1 parallel-group study that examined the single-dose (day 1) and multiple-dose (days 4-8) - 40 mg - pharmacokinetics of AZL and M-II in 16 subjects with mild and moderate hepatic impairment by Child-Pugh classification (n = 8 per group) and subjects (n = 16) matched based on age, sex, race, weight, and smoking status. Mild or moderate hepatic impairment did not cause clinically meaningful increases in exposure to AZL and M-II. Mild or moderate hepatic impairment had no clinically meaningful effect on the plasma protein binding of AZL and M-II. Single and multiple doses of AZL-M 40 mg were well tolerated in all subject groups. Based on the pharmacokinetic and tolerability findings, no dose adjustment of AZL-M is required for subjects with mild and moderate hepatic impairment. © 2017, The Authors. The Journal of Clinical Pharmacology published by Wiley Periodicals, Inc. on behalf of American College of Clinical Pharmacology.
Ryan, R M; Wilding, G E; Wynn, R J; Welliver, R C; Holm, B A; Leach, C L
2011-09-01
The objective of this study was to test the hypothesis that enhanced ultraviolet germicidal irradiation (eUVGI) installed in our neonatal intensive care unit (NICU) heating ventilation and air conditioning system (HVAC) would decrease HVAC and NICU environment microbes, tracheal colonization and ventilator-associated pneumonia (VAP). The study was designed as a prospective interventional pre- and post-single-center study. University-affiliated Regional Perinatal Center NICU. Intubated patients in the NICU were evaluated for colonization, and a high-risk sub-population of infants <30 weeks gestation ventilated for ≥ 14 days was studied for VAP. eUVGI was installed in the NICU's remote HVACs. The HVACs, NICU environment and intubated patients' tracheas were cultured pre- and post-eUVGI for 12 months. The high-risk patients were studied for VAP (positive bacterial tracheal culture, increased ventilator support, worsening chest radiograph and ≥ 7 days of antibiotics). Pseudomonas, Klebsiella, Serratia, Acinetobacter, Staphylococcus aureus and Coagulase-negative Staphylococcus species were cultured from all sites. eUVGI significantly decreased HVAC organisms (baseline 500,000 CFU cm(-2); P=0.015) and NICU environmental microbes (P<0.0001). Tracheal microbial loads decreased 45% (P=0.004), and fewer patients became colonized. VAP in the high-risk cohort fell from 74% (n=31) to 39% (n=18), P=0.04. VAP episodes per patient decreased (Control: 1.2 to eUVGI: 0.4; P=0.004), and antibiotic usage was 62% less (P=0.013). eUVGI decreased HVAC microbial colonization and was associated with reduced NICU environment and tracheal microbial colonization. Significant reductions in VAP and antibiotic use were also associated with eUVGI in this single-center study. Large randomized multicenter trials are needed.
NASA Astrophysics Data System (ADS)
Topaz, On; Luxenberg, Michael; Schumacher, Audrey
1994-07-01
Clinical experience with the mid IR holmium:YAG laser in a single medical center (St. Paul Ramsey Medical Center, University of Minnesota Medical School, St. Paul, MN) includes 112 patients who underwent holmium laser coronary angioplasty. Utilizing a unique lasing technique; `pulse and retreat,' we applied this laser to thrombotic and nonthrombotic lesions in patients presenting with unstable angina, stable angina, and acute myocardial infarction. A very high clinical success and very low complication rates were achieved. Holmium:YAG laser is effective and safe therapy for patients with symptomatic coronary artery disease. Unlike excimer lasers, the clinical success, efficacy and safety of holmium laser angioplasty is not compromised when thrombus is present.
OptiCentric lathe centering machine
NASA Astrophysics Data System (ADS)
Buß, C.; Heinisch, J.
2013-09-01
High precision optics depend on precisely aligned lenses. The shift and tilt of individual lenses as well as the air gap between elements require accuracies in the single micron regime. These accuracies are hard to meet with traditional assembly methods. Instead, lathe centering can be used to machine the mount with respect to the optical axis. Using a diamond turning process, all relevant errors of single mounted lenses can be corrected in one post-machining step. Building on the OptiCentric® and OptiSurf® measurement systems, Trioptics has developed their first lathe centering machines. The machine and specific design elements of the setup will be shown. For example, the machine can be used to turn optics for i-line steppers with highest precision.
Broad band antennas and feed methods
DOE Office of Scientific and Technical Information (OSTI.GOV)
Benzel, David M.; Twogood, Richard E.
Two or more Vivaldi antennas, consisting of two plates each, each with the antenna's natural impedance of approximately 100 ohms, are placed in parallel to achieve a 50 ohm impedance in the case of two antennas or other impedances (100/n ohms) for more than two antennas. A single Vivaldi antenna plate (half Vivaldi antenna) over a ground plane can also be used to achieve a 50 ohm impedance, or two or more single plates over a ground plane to achieve other impedances. Unbalanced 50 ohm transmission lines, e.g. coaxial cables, can be used to directly feed, the dual Vivaldi (fourmore » plate) antenna in a center fed angled center departure, or more desirably, a center fed offset departure configuration.« less
Katsanos, Konstantinos H; Tatsioni, Athina; Pedersen, Natalia; Shuhaibar, Mary; Ramirez, Vicent Hernandez; Politi, Patrizia; Rombrechts, Evelien; Pierik, Marieke; Clofent, Juan; Beltrami, Marina; Bodini, Paolo; Freitas, Joao; Mouzas, Ioannis; Fornaciari, Giovanni; Moum, Bjorn; Lakatos, Peter Laszlo; Vermeire, Severine; Langholz, Ebbe; Odes, Selwyn; Morain, Colm O'; Stockbrügger, Reinhold; Munkholm, Pia; Tsianos, Epameinondas V
2011-10-01
To determine the occurrence of intestinal and extraintestinal cancers in the 1993-2009 prospective European Collaborative Inflammatory Bowel Disease (EC-IBD) Study Group cohort. A physician per patient form was completed for 681 inflammatory bowel disease patients (445UC/236CD) from 9 centers (7 countries) derived from the original EC-IBD cohort. For the 15-year follow up period, rates of detection of intestinal and extraintestinal cancers were computed. Patient follow-up time was fifteen years. In total 62/681 patients (9.1%) [41 with ulcerative colitis/21 with Crohn's disease, 36 males/26 females] were diagnosed with sixty-six cancers (four patients with double cancers). Colorectal cancer was diagnosed in 9/681 patients [1.3%] (1 Crohn's disease and 8 ulcerative colitis). The remaining 53 cancers were extraintestinal. There was a higher prevalence of intestinal cancer in the Northern centers compared to Southern centers [p=NS]. Southern centers had more cases of extraintestinal cancer compared to Northern centers [p=NS]. The frequency of all observed types of cancers in Northern and in Southern centers did not differ compared to the expected one in the background population. In the fifteen-year follow up of the EC-IBD Study Group cohort the prevalence of cancer was 9.1% with most patients having a single neoplasm and an extraintestinal neoplasm. In Northern centers there were more intestinal cancers while in Southern centers there were more extraintestinal cancers compared to Northern centers. In this IBD cohort the frequency of observed cancers was not different from that expected in the background population. Copyright © 2011 European Crohn's and Colitis Organisation. Published by Elsevier B.V. All rights reserved.
Multimode and single-mode fibers for data center and high-performance computing applications
NASA Astrophysics Data System (ADS)
Bickham, Scott R.
2016-03-01
Data center (DC) and high performance computing (HPC) applications have traditionally used a combination of copper, multimode fiber and single-mode fiber interconnects with relative percentages that depend on factors such as the line rate, reach and connectivity costs. The balance between these transmission media has increasingly shifted towards optical fiber due to the reach constraints of copper at data rates of 10 Gb/s and higher. The percentage of single-mode fiber deployed in the DC has also grown slightly since 2014, coinciding with the emergence of mega DCs with extended distance needs beyond 100 m. This trend will likely continue in the next few years as DCs expand their capacity from 100G to 400G, increase the physical size of their facilities and begin to utilize silicon-photonics transceiver technology. However there is a still a need for the low-cost and high-density connectivity, and this is sustaining the deployment of multimode fiber for links <= 100 m. In this paper, we discuss options for single-mode and multimode fibers in DCs and HPCs and introduce a reduced diameter multimode fiber concept which provides intra-and inter-rack connectivity as well as compatibility with silicon-photonic transceivers operating at 1310 nm. We also discuss the trade-offs between single-mode fiber attributes such as bend-insensitivity, attenuation and mode field diameter and their roles in capacity and connectivity in data centers.
Single passenger rail car impact test. Volume III, Test procedures, instrumentation and data.
DOT National Transportation Integrated Search
2000-01-12
A full-scale impact test was performed November 16, 1999, at the Federal Railroad Administrations Transportation : Technology Center, Pueblo, Colorado, by Transportation Technology Center, Inc., a subsidiary of the Association of : American Railro...
Camp H.M. Smith and Navy Public Works Center Manana Title ...
Camp H.M. Smith and Navy Public Works Center Manana Title VII (Capehart) Housing, Three-Bedroom Single-Family Types 8 and 11, Birch Circle, Elm Drive, Elm Circle, and Date Drive, Pearl City, Honolulu County, HI
Camp H.M. Smith and Navy Public Works Center Manana Title ...
Camp H.M. Smith and Navy Public Works Center Manana Title VII (Capehart) Housing, U-Shaped Two-Bedroom Single-Family Type 6, Birch Circle, Elm Drive, Elm Circle, and Date Drive, Pearl City, Honolulu County, HI
Advertising by academic medical centers.
Larson, Robin J; Schwartz, Lisa M; Woloshin, Steven; Welch, H Gilbert
2005-03-28
Many academic medical centers have increased their use of advertising to attract patients. While the content of direct-to-consumer pharmaceutical advertisements (ads) has been studied, to our knowledge, advertising by academic medical centers has not. We aimed to characterize advertising by the nation's top academic medical centers. We contacted all 17 medical centers named to the US News & World Report 2002 honor roll of "America's Best Hospitals" for a semistructured interview regarding their advertising practices. In addition, we obtained and systematically analyzed all non-research-related print ads placed by these institutions in their 5 most widely circulating local newspapers during 2002. Of the 17 institutions, 16 reported advertising to attract patients; 1 stated, "We're just word of mouth." While all 17 centers confirmed the presence of an institutional review board process for approving advertising to attract research subjects, none reported a comparable process for advertising to attract patients. We identified 127 unique non-research-related print ads for the 17 institutions during 2002 (mean, 7.5; range, 0-39). Three ads promoted community events with institution sponsorship, 2 announced genuine public services, and 122 were aimed at attracting patients. Of the latter group, 36 ads (29.5%) promoted the medical center as a whole, while 65 (53.3%) promoted specific clinical departments and 21 (17.2%) promoted single therapeutic interventions or diagnostic tests. The most commonly used marketing strategies included appealing to emotions (61.5%), highlighting institution prestige (60.7%), mentioning a symptom or disease (53.3%), and promoting introductory lectures or special offers likely to lead to further business (47.5%). Of the 21 ads for single interventions, most were for unproved (38.1%) or cosmetic (28.6%) procedures. While more than half of these ads presented benefits, none quantified their positive claims and just 1 mentioned potential harms. Advertising to attract patients is common among top academic medical centers but is not subjected to the oversight standard for clinical research. Many of the ads seemed to place the interests of the medical center before the interests of the patients.
ERIC Educational Resources Information Center
FISCHER, JOHN H.
TO ASSIST IN DESEGREGATION, VARIOUS MODELS FOR THE SCHOOL PARK ARE PROPOSED--(1) ASSEMBLING ALL STUDENTS AND SCHOOLS OF A SMALL OR MEDIUM-SIZED COMMUNITY ON A SINGLE CAMPUS, (2) SERVING ONE SECTION OF A LARGE CITY, (3) CENTERING ALL SCHOOL FACILITIES FOR A SINGLE LEVEL OF EDUCATION ON A SINGLE SITE, AND (4) ESTABLISHING RINGS OF SCHOOL PARKS ABOUT…
The Effects of Ridge Axis Width on Mantle Melting at Mid-Ocean Ridges
NASA Astrophysics Data System (ADS)
Montesi, L.; Magni, V.; Gaina, C.
2017-12-01
Mantle upwelling in response to plate divergence produces melt at mid-ocean ridges. Melt starts when the solidus is crossed and stops when conductive cooling overcomes heat advection associated with the upwelling. Most mid-ocean ridge models assume that divergence takes place only in a narrow zone that defines the ridge axis, resulting in a single upwelling. However, more complex patterns of divergence are occasionally observed. The rift axis can be 20 km wide at ultraslow spreading center. Overlapping spreading center contain two parallel axes. Rifting in backarc basins is sometimes organized as a series of parallel spreading centers. Distributing plate divergence over several rifts reduces the intensity of upwelling and limits melting. Can this have a significant effect on the expected crustal thickness and on the mode of melt delivery at the seafloor? We address this question by modeling mantle flow and melting underneath two spreading centers separated by a rigid block. We adopt a non-linear rheology that includes dislocation creep, diffusion creep and yielding and include hydrothermal cooling by enhancing thermal conductivity where yielding takes place. The crustal thickness decreases if the rifts are separated by 30 km or more but only if the half spreading rate is between 1 and 2 cm/yr. At melting depth, a single upwelling remains the norm until the separation of the rifts exceeds a critical value ranging from 15 km in the fastest ridges to more than 50 km at ultraslow spreading centers. The stability of the central upwelling is due to hydrothermal cooling, which prevents hot mantle from reaching the surface at each spreading center. When hydrothermal cooling is suppressed, or the spreading centers are sufficiently separated, the rigid block becomes extremely cold and separates two distinct, highly asymmetric upwellings that may focus melt beyond the spreading center. In that case, melt delivery might drive further and further the divergence centers, whereas, when a single upwelling is retained, melt delivery would drive the spreading centers closer together. Thus, the system composed of two rifts is unstable and, if observed in nature, indicates either a transient geodynamic regime, like a recent change in spreading rates, or control structural or stress heterogeneities.
NASA Astrophysics Data System (ADS)
Li, Wei-bing; Li, Kang; Fan, Kan-qi; Zhang, Da-xing; Wang, Wei-dong
2018-04-01
Atomistic simulations are capable of providing insights into physical mechanisms responsible for mechanical properties of the transition metal of Tantalum (Ta). By using molecular dynamics (MD) method, temperature and pressure dependences of the elastic properties of Ta single crystals are investigated through <100> tensile loading. First of all, a comparative study between two types of embedded-atom method (EAM) potentials is made in term of the elastic properties of Ta single crystals. The results show that Ravelo-EAM (Physical Review B, 2013, 88: 134101) potential behaves well at different hydrostatic pressures. Then, the MD simulation results based on the Ravelo-EAM potential show that Ta will experience a body-centered-cubic (BCC) to face-centered-cubic (FCC) phase transition before fracture under <100> tensile loading at 1 K temperature, and model size and strain rate have no obvious effects on tensile behaviors of Ta. Next, from the simulation results at the system temperature from 1 to 1500 K, it can be derived that the elastic modulus of E 100 linearly decrease with the increasing temperature, while the yielding stress decrease with conforming a quadratic polynomial formula. Finally, the pressure dependence of the elastic properties is performed from 0 to 140 GPa and the observations show that the elastic modulus increases with the increasing pressure overall.
Li, Wei-Bing; Li, Kang; Fan, Kang-Qi; Zhang, Da-Xing; Wang, Wei-Dong
2018-04-24
Atomistic simulations are capable of providing insights into physical mechanisms responsible for mechanical properties of the transition metal of Tantalum (Ta). By using molecular dynamics (MD) method, temperature and pressure dependences of the elastic properties of Ta single crystals are investigated through <100> tensile loading. First of all, a comparative study between two types of embedded-atom method (EAM) potentials is made in term of the elastic properties of Ta single crystals. The results show that Ravelo-EAM (Physical Review B, 2013, 88: 134101) potential behaves well at different hydrostatic pressures. Then, the MD simulation results based on the Ravelo-EAM potential show that Ta will experience a body-centered-cubic (BCC) to face-centered-cubic (FCC) phase transition before fracture under <100> tensile loading at 1 K temperature, and model size and strain rate have no obvious effects on tensile behaviors of Ta. Next, from the simulation results at the system temperature from 1 to 1500 K, it can be derived that the elastic modulus of E 100 linearly decrease with the increasing temperature, while the yielding stress decrease with conforming a quadratic polynomial formula. Finally, the pressure dependence of the elastic properties is performed from 0 to 140 GPa and the observations show that the elastic modulus increases with the increasing pressure overall.
Freeman, Christine M; Crudgington, Sean; Stolberg, Valerie R; Brown, Jeanette P; Sonstein, Joanne; Alexis, Neil E; Doerschuk, Claire M; Basta, Patricia V; Carretta, Elizabeth E; Couper, David J; Hastie, Annette T; Kaner, Robert J; O'Neal, Wanda K; Paine, Robert; Rennard, Stephen I; Shimbo, Daichi; Woodruff, Prescott G; Zeidler, Michelle; Curtis, Jeffrey L
2015-01-27
Subpopulations and Intermediate Outcomes in COPD Study (SPIROMICS) is a multi-center longitudinal, observational study to identify novel phenotypes and biomarkers of chronic obstructive pulmonary disease (COPD). In a subset of 300 subjects enrolled at six clinical centers, we are performing flow cytometric analyses of leukocytes from induced sputum, bronchoalveolar lavage (BAL) and peripheral blood. To minimize several sources of variability, we use a "just-in-time" design that permits immediate staining without pre-fixation of samples, followed by centralized analysis on a single instrument. The Immunophenotyping Core prepares 12-color antibody panels, which are shipped to the six Clinical Centers shortly before study visits. Sputum induction occurs at least two weeks before a bronchoscopy visit, at which time peripheral blood and bronchoalveolar lavage are collected. Immunostaining is performed at each clinical site on the day that the samples are collected. Samples are fixed and express shipped to the Immunophenotyping Core for data acquisition on a single modified LSR II flow cytometer. Results are analyzed using FACS Diva and FloJo software and cross-checked by Core scientists who are blinded to subject data. Thus far, a total of 152 sputum samples and 117 samples of blood and BAL have been returned to the Immunophenotyping Core. Initial quality checks indicate useable data from 126 sputum samples (83%), 106 blood samples (91%) and 91 BAL samples (78%). In all three sample types, we are able to identify and characterize the activation state or subset of multiple leukocyte cell populations (including CD4+ and CD8+ T cells, B cells, monocytes, macrophages, neutrophils and eosinophils), thereby demonstrating the validity of the antibody panel. Our study design, which relies on bi-directional communication between clinical centers and the Core according to a pre-specified protocol, appears to reduce several sources of variability often seen in flow cytometric studies involving multiple clinical sites. Because leukocytes contribute to lung pathology in COPD, these analyses will help achieve SPIROMICS aims of identifying subgroups of patients with specific COPD phenotypes. Future analyses will correlate cell-surface markers on a given cell type with smoking history, spirometry, airway measurements, and other parameters. This study was registered with ClinicalTrials.gov as NCT01969344 .
Montgomery, Lara; Benzies, Karen; Barnard, Chantelle
2016-01-01
This pilot study evaluated the effects of an educational workshop on nurses' (N=36) attitudes and beliefs toward family-centered bedside rounds (FBR) using a single group, pretest/posttest design on two pediatric inpatient units at an academic tertiary-care center in Western Canada. The theory of planned behavior was used to develop the Nurses Attitudes and Behaviors about Rounds (NABAR) questionnaire. There were statistically significant increases between pretest and posttest scores on nurses' intentions, subjective norms and perceived behavioral control related to FBR, and on providing education to families about FBR. A brief, educational workshop can positively affect nurses' attitudes and beliefs about FBR. Future research should include additional psychometric evaluation of the NABAR. Copyright © 2016 Elsevier Inc. All rights reserved.
A review on single photon sources in silicon carbide.
Lohrmann, A; Johnson, B C; McCallum, J C; Castelletto, S
2017-03-01
This paper summarizes key findings in single-photon generation from deep level defects in silicon carbide (SiC) and highlights the significance of these individually addressable centers for emerging quantum applications. Single photon emission from various defect centers in both bulk and nanostructured SiC are discussed as well as their formation and possible integration into optical and electrical devices. The related measurement protocols, the building blocks of quantum communication and computation network architectures in solid state systems, are also summarized. This includes experimental methodologies developed for spin control of different paramagnetic defects, including the measurement of spin coherence times. Well established doping, and micro- and nanofabrication procedures for SiC may allow the quantum properties of paramagnetic defects to be electrically and mechanically controlled efficiently. The integration of single defects into SiC devices is crucial for applications in quantum technologies and we will review progress in this direction.
Al-Thani, Hassan; Jabbour, Gaby; El-Menyar, Ayman; Abdelrahman, Husham; Peralta, Ruben; Zarour, Ahmad
2018-01-01
Objective: To investigate the presentation, management and outcomes of left and right-sided traumatic diaphragmatic injury (TDI) in a single level I trauma center. Methods: This cross-sectional study was conducted during a 7-year period from 2008 to 2015 in a level I trauma center in Qatar. We included all the patients who presented with TDIs during the study period. Data included demographics, mechanism of injury, associated injuries, initial vitals, emergency department disposition, length of ICU and hospital stay, ventilator days, management, and outcomes. The variables were analyzed and compared for patients with left (LTDI) and right (RTDI). Results: A total of 52 TDI cases (79% LTDI and 21% RTDI) were identified with a mean age of 31±11. LTDI patients were more likely to have higher Injury severity scores (p=0.50) and greater AAST organ injury scoring (p=0.661 for all) than RTDI patients. Surgical repair was performed for 85% LTDI vs. 73% RTDI (p=0.342). Recurrent DIs was reported only in LTDI (5.1% vs. 0.0%; p=0.911). Twelve patients died (9 LTDI and 3 RTDI), of them 5 had associated head injury. Conclusion: This single-institution study confirms that LTDI are more commonly diagnosed than RTDI. Exploratory laparotomy is the most frequent procedure considered for the management of diaphragmatic injuries in the emergency settings. To improve outcomes in patients presenting with TDI, large prospective multicenter studies are needed to standardize the TDI management protocols including the diagnostic workup, timing of surgical intervention, and the most appropriate approach of treatment. PMID:29379805
Radiation accumulation of F{sub 2} color centers in LiF crystal
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lisitsyna, L. A.
2016-01-15
The paper presents the results of the research of the F{sub 2} centers accumulation dose dependences in the LiF crystals, the kinetics of absorption relaxation initiated by exposure to a single electron pulse in the band maxima of different electron centers obtained by time-resolved spectrometry with nanosecond resolution. An analytical description of the F{sub 2} center accumulation in an absorbed dose range ≤10{sup 3} Gy is provided.
NASA Astrophysics Data System (ADS)
Beckett, Douglas J. S.; Hickey, Ryan; Logan, Dylan F.; Knights, Andrew P.; Chen, Rong; Cao, Bin; Wheeldon, Jeffery F.
2018-02-01
Quantum dot comb sources integrated with silicon photonic ring-resonator filters and modulators enable the realization of optical sub-components and modules for both inter- and intra-data-center applications. Low-noise, multi-wavelength, single-chip, laser sources, PAM4 modulation and direct detection allow a practical, scalable, architecture for applications beyond 400 Gb/s. Multi-wavelength, single-chip light sources are essential for reducing power dissipation, space and cost, while silicon photonic ring resonators offer high-performance with space and power efficiency.
NASA Astrophysics Data System (ADS)
Asif, Rameez; Haithem, Mustafa
2018-03-01
We revisited our previous work "10 Gbit/s mode-multiplexed QPSK transmission using MDM-to-MFDM based single coherent receiver for intraand inter data center networking" [Opt. Commun. 391 (2017) 106-110] and discover a mistake in the Appendix 'A', i.e. mode-selective coherent detection technique. In this section, the direct referencing of the previous work at appropriate points is not adequate (page no. 109).
L10 FePtCu bit patterned media
NASA Astrophysics Data System (ADS)
Brombacher, C.; Grobis, M.; Lee, J.; Fidler, J.; Eriksson, T.; Werner, T.; Hellwig, O.; Albrecht, M.
2012-01-01
Chemically ordered 5 nm-thick L10 FePtCu films with strong perpendicular magnetic anisotropy were post-patterned by nanoimprint lithography into a dot array over a 3 mm-wide circumferential band on a 3 inch Si wafer. The dots with a diameter of 30 nm and a center-to-center pitch of 60 nm appear as single domain and reveal an enhanced switching field as compared to the continuous film. We demonstrate successful recording on a single track using shingled writing with a conventional hard disk drive write/read head.
Bogolon-mediated electron capture by impurities in hybrid Bose-Fermi systems
NASA Astrophysics Data System (ADS)
Boev, M. V.; Kovalev, V. M.; Savenko, I. G.
2018-04-01
We investigate the processes of electron capture by a Coulomb impurity center residing in a hybrid system consisting of spatially separated two-dimensional layers of electron and Bose-condensed dipolar exciton gases coupled via the Coulomb forces. We calculate the probability of the electron capture accompanied by the emission of a single Bogoliubov excitation (bogolon), similar to regular phonon-mediated scattering in solids. Furthermore, we study the electron capture mediated by the emission of a pair of bogolons in a single capture event and show that these processes not only should be treated in the same order of the perturbation theory, but also they give a more important contribution than single-bogolon-mediated capture, in contrast with regular phonon scattering.
NASA Technical Reports Server (NTRS)
Megie, G.; Menzies, R. T.
1979-01-01
The tunable single-longitudinal-mode operation of a TEA CO2 laser by an injection technique using a CW waveguide laser as the master oscillator is reported. With the experimental arrangement described, in which the waveguide laser frequency is tuned to correspond to one of the oscillating longitudinal modes of the TEA laser, single-longitudinal-mode operation was achieved with no apparent reduction in the TEA output energy, on various CO2 lines with frequency offsets from the line center as large as 300 MHz. The capability of this technique for high-resolution spectroscopy or atmospheric lidar studies is demonstrated by the recording of the absorption spectrum of a strong ozone line.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rocker, J.; Cornu, D.; Kieseritzky, E.
2014-08-01
A new ultrahigh vacuum (UHV) electron paramagnetic resonance (EPR) spectrometer operating at 94 GHz to investigate paramagnetic centers on single crystal surfaces is described. It is particularly designed to study paramagnetic centers on well-defined model catalysts using epitaxial thin oxide films grown on metal single crystals. The EPR setup is based on a commercial Bruker E600 spectrometer, which is adapted to ultrahigh vacuum conditions using a home made Fabry Perot resonator. The key idea of the resonator is to use the planar metal single crystal required to grow the single crystalline oxide films as one of the mirrors of themore » resonator. EPR spectroscopy is solely sensitive to paramagnetic species, which are typically minority species in such a system. Hence, additional experimental characterization tools are required to allow for a comprehensive investigation of the surface. The apparatus includes a preparation chamber hosting equipment, which is required to prepare supported model catalysts. In addition, surface characterization tools such as low energy electron diffraction (LEED)/Auger spectroscopy, temperature programmed desorption (TPD), and infrared reflection absorption spectroscopy (IRAS) are available to characterize the surfaces. A second chamber used to perform EPR spectroscopy at 94 GHz has a room temperature scanning tunneling microscope attached to it, which allows for real space structural characterization. The heart of the UHV adaptation of the EPR experiment is the sealing of the Fabry-Perot resonator against atmosphere. To this end it is possible to use a thin sapphire window glued to the backside of the coupling orifice of the Fabry Perot resonator. With the help of a variety of stabilization measures reducing vibrations as well as thermal drift it is possible to accumulate data for a time span, which is for low temperature measurements only limited by the amount of liquid helium. Test measurements show that the system can detect paramagnetic species with a density of approximately 5 × 10{sup 11} spins/cm{sup 2}, which is comparable to the limit obtained for the presently available UHV-EPR spectrometer operating at 10 GHz (X-band). Investigation of electron trapped centers in MgO(001) films shows that the increased resolution offered by the experiments at W-band allows to identify new paramagnetic species, that cannot be differentiated with the currently available methodology.« less
Resolving power of diffraction imaging with an objective: a numerical study.
Wang, Wenjin; Liu, Jing; Lu, Jun Qing; Ding, Junhua; Hu, Xin-Hua
2017-05-01
Diffraction imaging in the far-field can detect 3D morphological features of an object for its coherent nature. We describe methods for accurate calculation and analysis of diffraction images of scatterers of single and double spheres by an imaging unit based on microscope objective at non-conjugate positions. A quantitative study of the calculated diffraction imaging in spectral domain has been performed to assess the resolving power of diffraction imaging. It has been shown numerically that with coherent illumination of 532 nm in wavelength the imaging unit can resolve single spheres of 2 μm or larger in diameters and double spheres separated by less than 300 nm between their centers.
Void Growth and Coalescence in Dynamic Fracture of FCC and BCC Metals - Molecular Dynamics Study
NASA Astrophysics Data System (ADS)
Seppälä, Eira
2004-03-01
In dynamic fracture of ductile metals, the state of tension causes the nucleation of voids, typically from inclusions or grain boundary junctions, which grow and ultimately coalesce to form the fracture surface. Significant plastic deformation occurs in the process, including dislocations emitted to accommodate the growing voids. We have studied at the atomistic scale growth and coalescence processes of voids with concomitant dislocation formation. Classical molecular dynamics (MD) simulations of one and two pre-existing spherical voids initially a few nanometers in radius have been performed in single-crystal face-centered-cubic (FCC) and body-centered-cubic (BCC) lattices under dilational strain with high strain-rates. Million atom simulations of single void growth have been done to study the effect of stress triaxiality,^1 along with strain rate and lattice-structure dependence. An interesting prolate-to-oblate transition in the void shape in uniaxial expansion has been observed and quantitatively analyzed. The simulations also confirm that the plastic strain results directly from the void growth. Interaction and coalescence between two voids have been studied utilizing a parallel MD code in a seven million atom system. In particular, the movement of centers of the voids, linking of the voids, and the shape changes in vicinity of the other void are studied. Also the critical intervoid ligament distance after which the voids can be treated independently has been searched. ^1 E. T. Seppälä, J. Belak, and R. E. Rudd, cond-mat/0310541, submitted to Phys. Rev. B. Acknowledgment: This work was done in collaboration with Dr. James Belak and Dr. Robert E. Rudd, LLNL. It was performed under the auspices of the US Dept. of Energy at the Univ. of Cal./Lawrence Livermore National Laboratory under contract no. W-7405-Eng-48.
von Mechow, Stefanie; Graefen, Markus; Haese, Alexander; Tennstedt, Pierre; Pehrke, Dirk; Friedersdorff, Frank; Beyer, Burkhard
2018-06-01
To compare the duration of sick leave in patients with localized prostate cancer after robot-assisted radical prostatectomy (RARP) and open retropubic RP (ORP) at a German high-volume prostate cancer center. The data of 1,415 patients treated with RP at Martini Klinik, Prostate Cancer Center between 2012 and 2016 were, retrospectively, analyzed. Information on employment status, monthly revenues and days of work missed due to sickness were assessed via online questionnaire. Additional data were retrieved from our institutional database. Medians and interquartile ranges (IQR) were reported for continuous data. Cox proportional hazard analysis was performed to compare both surgical techniques for return to work time after RP. Median time elapsed between surgery and return to work comprised 42 days in patients undergoing RARP (IQR: 21-70) and ORP (IQR: 28-84, P = 0.05). In Cox regression analysis, surgical approach showed no impact on return to work time (RARP vs. ORP hazard ratio = 1, 95% CI: 0.91-1.16, P = 0.69). Return to work time was significantly associated with employment status, physical workload and monthly income (all P<0.001). Limitation of this study is the nonrandomized design in a single-center. As the surgical approach did not show any influence on the number of days missed from work in patients undergoing RP, no superiority of either RARP or ORP could be identified for return to work time in a German cohort. Both surgical approaches are safe options usually allowing the patients to resume normal activities including work after an appropriate convalescence period. Copyright © 2018 Elsevier Inc. All rights reserved.
Kangur, Liina; Jones, Michael R; Freiberg, Arvi
2017-12-01
Using the native bacteriochlorophyll a pigment cofactors as local probes, we investigated the response to external hydrostatic high pressure of reaction center membrane protein complexes from the photosynthetic bacterium Rhodobacter sphaeroides. Wild-type and engineered complexes were used with a varied number (0, 1 or 2) of hydrogen bonds that bind the reaction center primary donor bacteriochlorophyll cofactors to the surrounding protein scaffold. A pressure-induced breakage of hydrogen bonds was established for both detergent-purified and membrane-embedded reaction centers, but at rather different pressures: between 0.2 and 0.3GPa and at about 0.55GPa, respectively. The free energy change associated with the rupture of the single hydrogen bond present in wild-type reaction centers was estimated to be equal to 13-14kJ/mol. In the mutant with two symmetrical hydrogen bonds (FM197H) a single cooperative rupture of the two bonds was observed corresponding to an about twice stronger bond, rather than a sequential rupture of two individual bonds. Copyright © 2017 Elsevier B.V. All rights reserved.
Treatment planning for spinal radiosurgery : A competitive multiplatform benchmark challenge.
Moustakis, Christos; Chan, Mark K H; Kim, Jinkoo; Nilsson, Joakim; Bergman, Alanah; Bichay, Tewfik J; Palazon Cano, Isabel; Cilla, Savino; Deodato, Francesco; Doro, Raffaela; Dunst, Jürgen; Eich, Hans Theodor; Fau, Pierre; Fong, Ming; Haverkamp, Uwe; Heinze, Simon; Hildebrandt, Guido; Imhoff, Detlef; de Klerck, Erik; Köhn, Janett; Lambrecht, Ulrike; Loutfi-Krauss, Britta; Ebrahimi, Fatemeh; Masi, Laura; Mayville, Alan H; Mestrovic, Ante; Milder, Maaike; Morganti, Alessio G; Rades, Dirk; Ramm, Ulla; Rödel, Claus; Siebert, Frank-Andre; den Toom, Wilhelm; Wang, Lei; Wurster, Stefan; Schweikard, Achim; Soltys, Scott G; Ryu, Samuel; Blanck, Oliver
2018-05-25
To investigate the quality of treatment plans of spinal radiosurgery derived from different planning and delivery systems. The comparisons include robotic delivery and intensity modulated arc therapy (IMAT) approaches. Multiple centers with equal systems were used to reduce a bias based on individual's planning abilities. The study used a series of three complex spine lesions to maximize the difference in plan quality among the various approaches. Internationally recognized experts in the field of treatment planning and spinal radiosurgery from 12 centers with various treatment planning systems participated. For a complex spinal lesion, the results were compared against a previously published benchmark plan derived for CyberKnife radiosurgery (CKRS) using circular cones only. For two additional cases, one with multiple small lesions infiltrating three vertebrae and a single vertebra lesion treated with integrated boost, the results were compared against a benchmark plan generated using a best practice guideline for CKRS. All plans were rated based on a previously established ranking system. All 12 centers could reach equality (n = 4) or outperform (n = 8) the benchmark plan. For the multiple lesions and the single vertebra lesion plan only 5 and 3 of the 12 centers, respectively, reached equality or outperformed the best practice benchmark plan. However, the absolute differences in target and critical structure dosimetry were small and strongly planner-dependent rather than system-dependent. Overall, gantry-based IMAT with simple planning techniques (two coplanar arcs) produced faster treatments and significantly outperformed static gantry intensity modulated radiation therapy (IMRT) and multileaf collimator (MLC) or non-MLC CKRS treatment plan quality regardless of the system (mean rank out of 4 was 1.2 vs. 3.1, p = 0.002). High plan quality for complex spinal radiosurgery was achieved among all systems and all participating centers in this planning challenge. This study concludes that simple IMAT techniques can generate significantly better plan quality compared to previous established CKRS benchmarks.
Measuring Child-Staff Ratios in Child Care Centers: Balancing Effort and Representativeness
ERIC Educational Resources Information Center
Le, Vi-Nhuan; Perlman, Michal; Zellman, Gail L.; Hamilton, Laura S.
2006-01-01
Child-staff ratios are an important quality indicator. They are often collected by observing one randomly selected classroom several times during a 2-h period on a single day. However, it is unclear whether these measures represent the ratios that children actually experience during most of their time in care. This study compared ratio data…
Teaming and Teaching in ECE: Neoliberal Reforms, Teacher Metaphors, and Identity in Head Start
ERIC Educational Resources Information Center
Bullough, Robert V., Jr.
2015-01-01
Noting that surprisingly little researcher attention has been directed toward teaming in early childhood education (ECE), the author conducted parallel case studies of two Head Start teacher teams in a single center. Drawing on interviews, extensive observational notes taken over the course of a school year, and teacher-generated metaphors, the…
USDA-ARS?s Scientific Manuscript database
Benefits of plant sterols (PS) for cholesterol lowering are compromised by large variability in efficacy across individuals. High fractional cholesterol synthesis measured by deuterium incorporation has been associated with non-response to PS consumption; however, prospective studies showing this as...
ERIC Educational Resources Information Center
Fadale, LaVerna M.; Winter, Gene M.
The Two-Year College Development Center undertook a project to identify two-year college programs in New York State that successfully serve one or more of the special needs populations targeted by the Carl D. Perkins Act. Four special needs populations were targeted for in-depth study: single parents/homemakers, learning disabled, limited English…
Optical Modification of a Single Impurity Molecule in a Solid
1991-10-17
have led to direct observations of the lifetime-limited homogeneous Iinewidth of a single pentacene molecule as well as the surprising observation of...advances in the optical detection and spectroscopy of single impurity centers in solids. For the system composed of pentacene impurity molecules in the...limited homogcncous linewidth of a single pentacene molecule as well as the surprising observation of spontaneous spectral diffusion in a crystal
Santori, G; Andorno, E; Morelli, N; Casaccia, M; Bottino, G; Di Domenico, S; Valente, U
2009-05-01
In many Western countries a "minimum volume rule" policy has been adopted as a quality measure for complex surgical procedures. In Italy, the National Transplant Centre set the minimum number of orthotopic liver transplantation (OLT) procedures/y at 25/center. OLT procedures performed in a single center for a reasonably large period may be treated as a time series to evaluate trend, seasonal cycles, and nonsystematic fluctuations. Between January 1, 1987 and December 31, 2006, we performed 563 cadaveric donor OLTs to adult recipients. During 2007, there were another 28 procedures. The greatest numbers of OLTs/y were performed in 2001 (n = 51), 2005 (n = 50), and 2004 (n = 49). A time series analysis performed using R Statistical Software (Foundation for Statistical Computing, Vienna, Austria), a free software environment for statistical computing and graphics, showed an incremental trend after exponential smoothing as well as after seasonal decomposition. The predicted OLT/mo for 2007 calculated with the Holt-Winters exponential smoothing applied to the previous period 1987-2006 helped to identify the months where there was a major difference between predicted and performed procedures. The time series approach may be helpful to establish a minimum volume/y at a single-center level.
Bioequivalence of fixed-dose combination RIN®-150 to each reference drug in loose combination.
Wang, H F; Wang, R; O'Gorman, M; Crownover, P; Damle, B
2015-03-01
RIN(®)-150 is a fixed-dose combination (FDC) tablet containing rifampicin (RMP, 150 mg) and isoniazid (INH, 75 mg) developed for the treatment of tuberculosis. This study was conducted at a single center: the Pfizer Clinical Research Unit in Singapore. To demonstrate bioequivalence of each drug component between RIN-150 and individual products in a loose combination. This was a randomized, open-label, single-dose, two-way crossover study. Subjects received single doses of RIN-150 or two individual reference products under fasting conditions in a crossover fashion, with at least 7 days washout between doses. The primary measures for comparison were peak plasma concentration (Cmax) and the area under plasma concentration-time curve (AUC). Of 28 subjects enrolled, 26 completed the study. The adjusted geometric mean ratios of Cmax and AUClast between the FDC and single-drug references and 90% confidence intervals were respectively 91.63% (90%CI 83.13-101.01) and 95.45% (90%CI 92.07-98.94) for RMP, and 107.58% (90%CI 96.07-120.47) and 103.45% (90%CI 99.33-107.75) for INH. Both formulations were generally well tolerated in this study. The RIN-150 FDC tablet formulation is bioequivalent to the two single-drug references for RMP and INH at equivalent doses.
Baltà Cruz, S; Moreno Ribera, N; Estrach Panella, M T
Although Mercromina Film and other topical antiseptics are widely used, they are not included in the standard series recommended by the Spanish Contact Dermatitis and Skin Allergy Research Group for testing suspected allergic contact dermatitis (ACD). Furthermore, no recent studies have investigated the allergenic potential of merbromin. To determine the allergenic potential of merbromin and compare it with that of other topical antiseptics widely used in clinical practice, including povidone-iodine, chlorhexidine, and eosin. Prospective single-center observational safety study of 105 patients with suspected ACD seen at the dermatology department of our hospital. Of the 105 patients studied, 1.9% had a positive patch test to merbromin and 12.4% were sensitized to povidone-iodine. The differences in the proportion of patients with ACD to Betadine Solución Dérmica (povidone-iodine) compared with the rest of the antiseptics was statistically significant (McNemar test, P<.05). No adverse reactions were observed in any of the patients. Based on the patch tests conducted, Mercromina Film has very low allergenic potential. The highest allergenic potential was observed for povidone-iodine. Copyright © 2017 AEDV. Publicado por Elsevier España, S.L.U. All rights reserved.
Mushkudiani, Nino A; Hukkelhoven, Chantal W P M; Hernández, Adrián V; Murray, Gordon D; Choi, Sung C; Maas, Andrew I R; Steyerberg, Ewout W
2008-04-01
To describe the modeling techniques used for early prediction of outcome in traumatic brain injury (TBI) and to identify aspects for potential improvements. We reviewed key methodological aspects of studies published between 1970 and 2005 that proposed a prognostic model for the Glasgow Outcome Scale of TBI based on admission data. We included 31 papers. Twenty-four were single-center studies, and 22 reported on fewer than 500 patients. The median of the number of initially considered predictors was eight, and on average five of these were selected for the prognostic model, generally including age, Glasgow Coma Score (or only motor score), and pupillary reactivity. The most common statistical technique was logistic regression with stepwise selection of predictors. Model performance was often quantified by accuracy rate rather than by more appropriate measures such as the area under the receiver-operating characteristic curve. Model validity was addressed in 15 studies, but mostly used a simple split-sample approach, and external validation was performed in only four studies. Although most models agree on the three most important predictors, many were developed on small sample sizes within single centers and hence lack generalizability. Modeling strategies have to be improved, and include external validation.
Pros and cons of using paid feeding assistants in nursing homes.
Remsburg, Robin E
2004-01-01
Recently the Centers for Medicare and Medicaid Services (CMS), citing increasing resident acuity, staffing shortages, and high turnover rates that make it difficult for nursing homes to provide adequate feeding assistance to residents who need minimal help at mealtimes, began allowing nursing facilities to use single-task workers to provide assistance during mealtimes. This article describes the use of single-task workers to provide feeding assistance to nutritionally at-risk residents during a 6-month clinical study designed to evaluate the effectiveness and feasibility of implementing a buffet-dining program in an academic long-term care facility.
Plasmonic enhancement of a silicon-vacancy center in a nanodiamond crystal
NASA Astrophysics Data System (ADS)
Meng, Xiang; Liu, Shang; Dadap, Jerry I.; Osgood, Richard M.
2017-06-01
This work reports a rigorous and comprehensive three-dimensional electromagnetic computation to investigate and design photoluminescence enhancement from a single silicon-vacancy center (SVC) in a nanodiamond crystal embedded in various metallic nanoantennae, each having a different geometry. The study demonstrates how each antenna design enhances the photoluminescence of SVCs in diamond. In particular, our report discusses how the 2D or 3D curvature of the nanoantenna and the control of the local environment of the SVC can lead to significant field enhancement of its optical field. Our calculated optimal photoluminescence for each design enhances the emission intensity by 15 -300 × that of a single SVC without antenna. The enhancement mechanisms are investigated using four representative structures that can be fabricated under feasible and realistic growth conditions, i.e., spherical-, nanorod-, nanodisk-dimer, and bow-tie nanoantennae. These results demonstrate a method for rationally designing arbitrary metallic nanoantenna/emitter assemblies to achieve optimal SVC photoluminescence.
Management of LVAD Patients for Noncardiac Surgery: A Single-Institution Study.
Nelson, Eric W; Heinke, Timothy; Finley, Alan; Guldan, G J; Gaddy, Parker; Matthew Toole, J; Mims, Ryan; Abernathy, J H
2015-08-01
To describe the experience regarding the perioperative management of patients with left ventricular assist devices (LVADs) who require anesthesia while undergoing noncardiac surgery (NCS) at a single medical center. Retrospective chart review Academic medical center Patients with LVADs Medical records from April 1, 2009 through January 31, 2014 were reviewed for patients who underwent Heartmate II LVAD placement at this facility. Individual records were reviewed for NCS after LVAD placement, specifically investigating perioperative and anesthetic management. Seventy-one patients underwent LVAD placement during this time period. Thirty-five patients (49%) underwent a total of 101 NCS procedures. Arterial catheters were placed in 19 patients (19%), and 33 patients (33%) were intubated for their procedure. No complications or perioperative mortality occurred related to the NCS. Noncardiac surgery is becoming more common in patients with LVADs. Anesthetic management of these patients outside of the cardiac operating room is limited. Patients with Heartmate II LVADs can safely undergo noncardiac surgery. Copyright © 2015 Elsevier Inc. All rights reserved.
High-power single-stage thulium-doped superfluorescent fiber source
NASA Astrophysics Data System (ADS)
Hu, Z. Y.; Yan, P.; Liu, Q.; Ji, E. C.; Xiao, Q. R.; Gong, M. L.
2015-01-01
In this paper, we report a high-power thulium (Tm)-doped superfluorescent fiber source (SFS) in the 2-μm spectral region. The SFS is based on double angle-cleaved facet operation and uses a simple single-stage geometry. The copropagating amplified spontaneous emission (ASE) yields a maximum output of 20.7 W at a center wavelength of 1,960.7 nm, with a full width at half maximum (FWHM) of ~45 nm. The counterpropagating ASE yields a maximum output of 25.2 W at a center wavelength of 1,948.2 nm, with a FWHM of ~50 nm. The maximum combined output of the SFS is as much as 45.9 W, which corresponds to a slope efficiency of 38.9 %. In addition, a model of the ~2 μm SFS in Tm-doped silica fibers pumped at ~790 nm is developed, and the influence of fiber length and end-facet reflectivity on the ASE output performance and the parasitic lasing threshold are studied numerically.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hong, Jeong-Ho; Kang, Jihoon; Yeo, Min-Ju
PurposeCarotid endarterectomy and stenting are used to treat carotid stenosis, with the volume of carotid artery procedures increasing over the past decade. We investigated the 10-year trend of periprocedural complications with an increasing procedure volume of carotid stenting at a single tertiary hospital.MethodsWe collected 416 consecutive cases (384 patients) of carotid artery stenting performed for either symptomatic (231 cases, 55.5 %) or asymptomatic (185 cases, 44.5 %) internal carotid artery stenosis at a single center. Periprocedural complication was defined as any stroke, myocardial infarction, or death. Procedure-related outcome included any dissection, hemodynamic event, or periprocedural complication.ResultsThe mean age was 68.8 years (82.8 % males;more » range of 20–89 years); 23.9 % were older than 75 years. Before the procedure, 99.3 and 56.0 % of patients received antiplatelet and lipid-lowering medication, respectively. The overall periprocedural complication rate was 3.6 % (1.6 and 5.2 % in the asymptomatic and symptomatic group, respectively). The composite outcome of any stroke or death was 3.4 %. Periprocedural complication and procedure-related outcome showed a decremental trend with increasing procedure volume, and this trend remained after adjusting for confounders.ConclusionsOur study suggests that carotid stenting at an experienced center might reduce the periprocedural complications. Our periprocedural complication rate of carotid artery stenting may be comparable to, or somewhat lower than, that reported in other clinical trials.« less
Selective alkane activation with single-site atoms on amorphous support
Hock, Adam S.; Schweitzer, Neil M.; Miller, Jeffrey T.; Hu, Bo
2015-11-24
The present invention relates generally to catalysts and methods for use in olefin production. More particularly, the present invention relates to novel amorphously supported single-center, Lewis acid metal ions and use of the same as catalysts.
Plasma-enhanced pulsed-laser deposition of single-crystalline M o2C ultrathin superconducting films
NASA Astrophysics Data System (ADS)
Zhang, Fan; Zhang, Zhi; Wang, Huichao; Chan, Cheuk Ho; Chan, Ngai Yui; Chen, Xin Xin; Dai, Ji-Yan
2017-08-01
Transition-metal carbides (TMCs) possess many intriguing properties and inspiring application potentials, and recently the study of a two-dimensional form of TMCs has attracted great attention. Herein, we report successful fabrication of continuous M o2C ultrathin single-crystalline films at 700 ∘C with an approach of plasma-enhanced pulsed-laser deposition. By sophisticated structural analyses, the M o2C films are characterized as single crystal with a rarely reported face-centered cubic structure. In further electrical transport measurements, superconductivity observed in the M o2C films demonstrates a typical two-dimensional feature, which is consistent with Berezinskii-Kosterlitz-Thouless transitions. Besides, large upper critical magnetic fields are discovered in this system. Our work offers an approach to grow large-area and high-quality TMCs at relatively low temperatures. This study may stimulate more related investigations on the synthesis, characterizations, and applications of two-dimensional TMCs.
Robotic-assisted single-port donor nephrectomy using the da Vinci single-site platform.
LaMattina, John C; Alvarez-Casas, Josue; Lu, Irene; Powell, Jessica M; Sultan, Samuel; Phelan, Michael W; Barth, Rolf N
2018-02-01
Although single-port donor nephrectomy offers improved cosmetic outcomes, technical challenges have limited its application to selected centers. Our center has performed over 400 single-port donor nephrectomies. The da Vinci single-site robotic platform was utilized in an effort to overcome the steric, visualization, ergonomic, and other technical limitations associated with the single-port approach. Food and Drug Administration device exemption was obtained. Selection criteria for kidney donation included body mass index <35, left kidney donors, and ≤2 renal arteries. After colonic mobilization using standard single-port techniques, the robotic approach was utilized for ureteral complex and hilar dissection. Three cases were performed using the robotic single-site platform. Average total operative time was 262 ± 42 min including 82 ± 16 min of robotic use. Docking time took 20 ± 10 min. Blood loss averaged 77 ± 64 mL. No intraoperative complications occurred, and all procedures were completed with our standard laparoscopic single-port approach. This is the first clinical experience of robotic-assisted donor nephrectomy utilizing the da Vinci single-site platform. Our experience supported the safety of this approach but found that the technology added cost and complexity without tangible benefit. Development of articulating instruments, energy, and stapling devices will be necessary for increased application of robotic single-site surgery for donor nephrectomy. Copyright © 2017 Elsevier Inc. All rights reserved.
The Minnesota Center for Twin and Family Research Genome-Wide Association Study
Miller, Michael B.; Basu, Saonli; Cunningham, Julie; Eskin, Eleazar; Malone, Steven M.; Oetting, William S.; Schork, Nicholas; Sul, Jae Hoon; Iacono, William G.; Mcgue, Matt
2012-01-01
As part of the Genes, Environment and Development Initiative (GEDI), the Minnesota Center for Twin and Family Research (MCTFR) undertook a genome-wide association study (GWAS), which we describe here. A total of 8405 research participants, clustered in 4-member families, have been successfully genotyped on 527,829 single nucleotide polymorphism (SNP) markers using Illumina’s Human660W-Quad array. Quality control screening of samples and markers as well as SNP imputation procedures are described. We also describe methods for ancestry control and how the familial clustering of the MCTFR sample can be accounted for in the analysis using a Rapid Feasible Generalized Least Squares algorithm. The rich longitudinal MCTFR assessments provide numerous opportunities for collaboration. PMID:23363460
Single photon quantum cryptography.
Beveratos, Alexios; Brouri, Rosa; Gacoin, Thierry; Villing, André; Poizat, Jean-Philippe; Grangier, Philippe
2002-10-28
We report the full implementation of a quantum cryptography protocol using a stream of single photon pulses generated by a stable and efficient source operating at room temperature. The single photon pulses are emitted on demand by a single nitrogen-vacancy color center in a diamond nanocrystal. The quantum bit error rate is less that 4.6% and the secure bit rate is 7700 bits/s. The overall performances of our system reaches a domain where single photons have a measurable advantage over an equivalent system based on attenuated light pulses.
NASA Technical Reports Server (NTRS)
Jones, H. W.
1984-01-01
The computer-assisted C-matrix, Loewdin-alpha-function, single-center expansion method in spherical harmonics has been applied to the three-center nuclear-attraction integral (potential due to the product of separated Slater-type orbitals). Exact formulas are produced for 13 terms of an infinite series that permits evaluation to ten decimal digits of an example using 1s orbitals.
Combination products regulation at the FDA.
Lauritsen, K J; Nguyen, T
2009-05-01
The US Food and Drug Administration (FDA) is responsible for protecting the public health by assuring the safety, efficacy, and security of drugs, biological products, and medical devices. As single-entity products, drugs are generally regulated by the Center for Drug Evaluation and Research (CDER), devices by the Center for Devices and Radiological Health (CDRH), and biologics by the Center for Biologics Evaluation and Research (CBER). In recent years, technological advances have led to a blurring of the historical lines of separation between the centers.
Dependence of the phototropic response of Arabidopsis thaliana on fluence rate and wavelength
DOE Office of Scientific and Technical Information (OSTI.GOV)
Konjevic, R.; Steinitz, B.; Poff, K.L.
1989-12-01
In the phototropic response of Arabidopsis thaliana seedlings, the shape of the fluence-response relation depends on fluence rate and wavelength. At low fluence rates, the response to 450-nm light is characterized by a single maximum at about 0.3 {mu}mol{center dot}m{sup {minus}2}. At higher fluence rates, the response shows two distinct maxima, I and II, at 0.3 and 3.5 {mu}mol{center dot}m{sup {minus}2}, respectively. The response to 500-nm light shows a single maximum at 2 {mu}mol{center dot}m{sup {minus}2}, and the response to 510-nm light shows a single maximum at 4.5 {mu}mol{center dot}m{sup {minus}2}, independent of fluence rate. The response to 490-nm lightmore » shows a maximal at 4.5 {mu}mol{center dot}m{sup {minus}2} and a shoulder at about 0.6 {mu}mol{center dot}m{sup {minus}2}. Preirradiation with high-fluence 510-nm light from above, immediately followed by unilateral 450-nm light, eliminates maximum II but not maximum I. Preirradiation with high-fluence 450-nm light from above eliminates the response to subsequent unilateral irradiation with either 450-nm or 510-nm light. The recovery of the response following high-fluence 450-nm light is considerably slower than the recovery following high-fluence 510-nm light. Unilateral irradiation with low-fluence 510-nm light followed by 450-nm light results in curvature that is approximately the sum of those produced by either irradiation alone. Based on these results, it is proposed that phototropism in A. thaliana seedlings is mediated by at least two blue-light photoreceptor pigments.« less
Grochowiecki, T; Jakimowicz, T; Grabowska-Derlatka, L; Szmidt, J
2014-10-01
The high rate of complication after pancreas transplantation not only had an impact on recipient quality of life and survival but also had significant financial implications. Thus, monitoring transplant center performance was crucial to indentifying changes in clinical practice that result in quality deterioration. To evaluate retrospectively the quality of the single, small pancreatic transplant program and to establish prospective monitoring of the center using risk-adjusted cumulative sum (CUSUM). From 1988 to 2014, 119 simultaneous pancreas and the kidney transplantations (SPKTx) were performed. The program was divided into 3 eras, based on surgical technique and immunosuppression. Analyses of the 15 fatal outcomes due to complication from pancreatic graft were performed. The risk model was developed using multivariable logistic regression analysis based on retrospective data of 112 SPKTx recipients. The risk-adjusted 1-sided CUSUM chart was plotted for retrospective and prospective events. The upper control limit was set to 2. There were 2 main causes of death: multiorgan failure (73.3%; 11/15) and septic hemorrhage (26.7%; 4/15). Quality analysis using the CUSUM chart revealed that the process was not homogeneous; however, no significant signal of program deterioration was obtained and the performance of the whole program was within the settled control limit. For a single pancreatic transplant center. The risk-adjusted CUSUM chart was a useful tool for quality program assessment. It could support decision making during traditional surgical morbidity and mortality conferences. For small transplant centers, increasing the sensitivity of the CUSUM method by lowering the upper control limit should be considered. However, an individual assessment approach of the for particular centers is recommended.
The effect of cane use on the compensatory step following posterior perturbations.
Hall, Courtney D; Jensen, Jody L
2004-08-01
The compensatory step is a critical component of the balance response and is impaired in older fallers. The purpose of this research was to examine whether utilization of a cane modified the compensatory step response following external posterior perturbations. Single subject withdrawal design was employed. Single subject statistical analysis--the standard deviation bandwidth-method--supplemented visual analysis of the data. Four older adults (range: 73-83 years) with balance impairment who habitually use a cane completed this study. Subjects received a series of sudden backward pulls that were large enough to elicit compensatory stepping. We examined the following variables both with and without cane use: timing of cane loading relative to step initiation and center of mass acceleration, stability margin, center of mass excursion and velocity, step length and width. No participant loaded the cane prior to initiation of the first compensatory step. There was no effect of cane use on the stability margin, nor was there an effect of cane use on center of mass excursion or velocity, or step length or width. These data suggest that cane use does not necessarily improve balance recovery following an external posterior perturbation when the individual is forced to rely on compensatory stepping. Instead these data suggest that the strongest factor in modifying step characteristics is experience with the perturbation.
Dimer self-organization of impurity ytterbium ions in synthetic forsterite single crystals
NASA Astrophysics Data System (ADS)
Tarasov, V. F.; Sukhanov, A. A.; Dudnikova, V. B.; Zharikov, E. V.; Lis, D. A.; Subbotin, K. A.
2017-07-01
Paramagnetic centers formed by impurity Yb3+ ions in synthetic forsterite (Mg2SiO4) grown by the Czochralski technique are studied by X-band CW and pulsed EPR spectroscopy. These centers are single ions substituting magnesium in two different crystallographic positions denoted M1 and M2, and dimer associates formed by two Yb3+ ions in nearby positions M1. It is established that there is a pronounced mechanism favoring self-organization of ytterbium ions in dimer associates during the crystal growth, and the mechanism of the spin-spin coupling between ytterbium ions in the associate has predominantly a dipole-dipole character, which makes it possible to control the energy of the spin-spin interaction by changing the orientation of the external magnetic field. The structural computer simulation of cluster ytterbium centers in forsterite crystals is carried out by the method of interatomic potentials using the GULP 4.0.1 code (General Utility Lattice Program). It is established that the formation of dimer associates in the form of a chain parallel to the crystallographic axis consisting of two ytterbium ions with a magnesium vacancy between them is the most energetically favorable for ytterbium ions substituting magnesium in the position M1.
Effects of Implied Motion and Facing Direction on Positional Preferences in Single-Object Pictures.
Palmer, Stephen E; Langlois, Thomas A
2017-07-01
Palmer, Gardner, and Wickens studied aesthetic preferences for pictures of single objects and found a strong inward bias: Right-facing objects were preferred left-of-center and left-facing objects right-of-center. They found no effect of object motion (people and cars showed the same inward bias as chairs and teapots), but the objects were not depicted as moving. Here we measured analogous inward biases with objects depicted as moving with an implied direction and speed by having participants drag-and-drop target objects into the most aesthetically pleasing position. In Experiment 1, human figures were shown diving or falling while moving forward or backward. Aesthetic biases were evident for both inward-facing and inward-moving figures, but the motion-based bias dominated so strongly that backward divers or fallers were preferred moving inward but facing outward. Experiment 2 investigated implied speed effects using images of humans, horses, and cars moving at different speeds (e.g., standing, walking, trotting, and galloping horses). Inward motion or facing biases were again present, and differences in their magnitude due to speed were evident. Unexpectedly, faster moving objects were generally preferred closer to frame center than slower moving objects. These results are discussed in terms of the combined effects of prospective, future-oriented biases, and retrospective, past-oriented biases.
Demographics of emergency medical care at the Indianapolis 500 mile race (1983-1990).
Bock, H C; Cordell, W H; Hawk, A C; Bowdish, G E
1992-10-01
The Indianapolis 500 Mile Race, the largest single-day, single-venue sporting event in the world, is attended by an estimated 400,000 people. Major illness and injury are treated at the Hanna Emergency Medical Center, the track hospital. Minor illness is treated at ten outlying aid stations. We describe the demographics of emergency medical care at the Hanna Emergency Medical Center. Descriptive. Patient care data for patients treated at the medical center are first recorded on paper charts and then coded and transferred to computer. Data regarding patients treated at the medical center during eight consecutive races (1983-1990) were analyzed. Frequency of treatment and medical cardiac arrest rates were calculated. Aid station data and medical center records from nonrace days were not analyzed. The average number of patients treated per year at the track hospital was 139. The total number treated over the eight-year period was 1,113, yielding a frequency of treatment of 0.35 per 1,000. Analysis showed 16.2% of the proprietary treatment codes involved intoxication; 15.4%, lacerations (other than feet); 11.0%, pre-existing conditions; and 8.5%, heat illness. During the eight years, there were four medical cardiac arrests (incidence of 0.0125 per 10,000 spectators), all resulting in death. A fifth spectator died after being struck by a wheel from a race car. There were no driver deaths on race day. Descriptive data regarding medical care of crowds may be useful to emergency specialists who must staff, order supplies, and plan treatment facilities for similar mass gatherings. It is evident from this and other mass-gathering studies that there is a need for consistency in nomenclature and data collection. This will allow more accurate comparisons of emergency medical care between venues.
Wei, Wei-Qi; Leibson, Cynthia L; Ransom, Jeanine E; Kho, Abel N; Caraballo, Pedro J; Chai, High Seng; Yawn, Barbara P; Pacheco, Jennifer A
2012-01-01
Objective To evaluate data fragmentation across healthcare centers with regard to the accuracy of a high-throughput clinical phenotyping (HTCP) algorithm developed to differentiate (1) patients with type 2 diabetes mellitus (T2DM) and (2) patients with no diabetes. Materials and methods This population-based study identified all Olmsted County, Minnesota residents in 2007. We used provider-linked electronic medical record data from the two healthcare centers that provide >95% of all care to County residents (ie, Olmsted Medical Center and Mayo Clinic in Rochester, Minnesota, USA). Subjects were limited to residents with one or more encounter January 1, 2006 through December 31, 2007 at both healthcare centers. DM-relevant data on diagnoses, laboratory results, and medication from both centers were obtained during this period. The algorithm was first executed using data from both centers (ie, the gold standard) and then from Mayo Clinic alone. Positive predictive values and false-negative rates were calculated, and the McNemar test was used to compare categorization when data from the Mayo Clinic alone were used with the gold standard. Age and sex were compared between true-positive and false-negative subjects with T2DM. Statistical significance was accepted as p<0.05. Results With data from both medical centers, 765 subjects with T2DM (4256 non-DM subjects) were identified. When single-center data were used, 252 T2DM subjects (1573 non-DM subjects) were missed; an additional false-positive 27 T2DM subjects (215 non-DM subjects) were identified. The positive predictive values and false-negative rates were 95.0% (513/540) and 32.9% (252/765), respectively, for T2DM subjects and 92.6% (2683/2898) and 37.0% (1573/4256), respectively, for non-DM subjects. Age and sex distribution differed between true-positive (mean age 62.1; 45% female) and false-negative (mean age 65.0; 56.0% female) T2DM subjects. Conclusion The findings show that application of an HTCP algorithm using data from a single medical center contributes to misclassification. These findings should be considered carefully by researchers when developing and executing HTCP algorithms. PMID:22249968
Choi, Inyoung; Choi, Ran; Lee, Jonghyun
2010-01-01
Objectives The objective of this research is to introduce the unique approach of the Catholic Medical Center (CMC) integrate network hospitals with organizational and technical methodologies adopted for seamless implementation. Methods The Catholic Medical Center has developed a new hospital information system to connect network hospitals and adopted new information technology architecture which uses single source for multiple distributed hospital systems. Results The hospital information system of the CMC was developed to integrate network hospitals adopting new system development principles; one source, one route and one management. This information architecture has reduced the cost for system development and operation, and has enhanced the efficiency of the management process. Conclusions Integrating network hospital through information system was not simple; it was much more complicated than single organization implementation. We are still looking for more efficient communication channel and decision making process, and also believe that our new system architecture will be able to improve CMC health care system and provide much better quality of health care service to patients and customers. PMID:21818432
DOT National Transportation Integrated Search
2000-05-24
A full-scale impact test was performed November 16, 1999, at the Federal Railroad Administration's Transportation Technology Center, Pueblo, Colorado, by Transportation Technology Center, Inc., a subsidiary of the Association of American Railroads. T...
Arroyo-Camejo, Silvia; Adam, Marie-Pierre; Besbes, Mondher; Hugonin, Jean-Paul; Jacques, Vincent; Greffet, Jean-Jacques; Roch, Jean-François; Hell, Stefan W; Treussart, François
2013-12-23
Nitrogen-vacancy (NV) color centers in nanodiamonds are highly promising for bioimaging and sensing. However, resolving individual NV centers within nanodiamond particles and the controlled addressing and readout of their spin state has remained a major challenge. Spatially stochastic super-resolution techniques cannot provide this capability in principle, whereas coordinate-controlled super-resolution imaging methods, like stimulated emission depletion (STED) microscopy, have been predicted to fail in nanodiamonds. Here we show that, contrary to these predictions, STED can resolve single NV centers in 40-250 nm sized nanodiamonds with a resolution of ≈10 nm. Even multiple adjacent NVs located in single nanodiamonds can be imaged individually down to relative distances of ≈15 nm. Far-field optical super-resolution of NVs inside nanodiamonds is highly relevant for bioimaging applications of these fluorescent nanolabels. The targeted addressing and readout of individual NV(-) spins inside nanodiamonds by STED should also be of high significance for quantum sensing and information applications.
Karaveli, Sinan; Gaathon, Ophir; Wolcott, Abraham; Sakakibara, Reyu; Shemesh, Or A.; Peterka, Darcy S.; Boyden, Edward S.; Owen, Jonathan S.; Yuste, Rafael; Englund, Dirk
2016-01-01
The negatively charged nitrogen vacancy (NV−) center in diamond has attracted strong interest for a wide range of sensing and quantum information processing applications. To this end, recent work has focused on controlling the NV charge state, whose stability strongly depends on its electrostatic environment. Here, we demonstrate that the charge state and fluorescence dynamics of single NV centers in nanodiamonds with different surface terminations can be controlled by an externally applied potential difference in an electrochemical cell. The voltage dependence of the NV charge state can be used to stabilize the NV− state for spin-based sensing protocols and provides a method of charge state-dependent fluorescence sensing of electrochemical potentials. We detect clear NV fluorescence modulation for voltage changes down to 100 mV, with a single NV and down to 20 mV with multiple NV centers in a wide-field imaging mode. These results suggest that NV centers in nanodiamonds could enable parallel optical detection of biologically relevant electrochemical potentials. PMID:27035935
Karaveli, Sinan; Gaathon, Ophir; Wolcott, Abraham; Sakakibara, Reyu; Shemesh, Or A; Peterka, Darcy S; Boyden, Edward S; Owen, Jonathan S; Yuste, Rafael; Englund, Dirk
2016-04-12
The negatively charged nitrogen vacancy (NV(-)) center in diamond has attracted strong interest for a wide range of sensing and quantum information processing applications. To this end, recent work has focused on controlling the NV charge state, whose stability strongly depends on its electrostatic environment. Here, we demonstrate that the charge state and fluorescence dynamics of single NV centers in nanodiamonds with different surface terminations can be controlled by an externally applied potential difference in an electrochemical cell. The voltage dependence of the NV charge state can be used to stabilize the NV(-) state for spin-based sensing protocols and provides a method of charge state-dependent fluorescence sensing of electrochemical potentials. We detect clear NV fluorescence modulation for voltage changes down to 100 mV, with a single NV and down to 20 mV with multiple NV centers in a wide-field imaging mode. These results suggest that NV centers in nanodiamonds could enable parallel optical detection of biologically relevant electrochemical potentials.
NASA Astrophysics Data System (ADS)
Karaveli, Sinan; Gaathon, Ophir; Wolcott, Abraham; Sakakibara, Reyu; Shemesh, Or A.; Peterka, Darcy S.; Boyden, Edward S.; Owen, Jonathan S.; Yuste, Rafael; Englund, Dirk
2016-04-01
The negatively charged nitrogen vacancy (NV-) center in diamond has attracted strong interest for a wide range of sensing and quantum information processing applications. To this end, recent work has focused on controlling the NV charge state, whose stability strongly depends on its electrostatic environment. Here, we demonstrate that the charge state and fluorescence dynamics of single NV centers in nanodiamonds with different surface terminations can be controlled by an externally applied potential difference in an electrochemical cell. The voltage dependence of the NV charge state can be used to stabilize the NV- state for spin-based sensing protocols and provides a method of charge state-dependent fluorescence sensing of electrochemical potentials. We detect clear NV fluorescence modulation for voltage changes down to 100 mV, with a single NV and down to 20 mV with multiple NV centers in a wide-field imaging mode. These results suggest that NV centers in nanodiamonds could enable parallel optical detection of biologically relevant electrochemical potentials.
A stimulus-centered reading disorder for words and numbers: Is it neglect dyslexia?
Arduino, Lisa S; Daini, Roberta; Caterina Silveri, Maria
2005-12-01
A single case, RCG, showing a unilateral reading disorder without unilateral spatial neglect was studied. The disorder was characterized by substitutions of the initial (left) letters of words, nonwords and Arabic numbers, independently of egocentered spatial coordinates. MRI showed a bilateral lesion with the involvement of the splenium. Although, within the framework of the visual word recognition model proposed by Caramazza and Hillis (1990), RCG disorder could be defined as a stimulus-centered neglect dyslexia, we discuss the hypothesis of a dissociation in neural correlates and mechanisms between the syndrome of unilateral spatial neglect and such a unilateral reading disorder.
Absorption and photoluminescence study of Al 2O 3 single crystal irradiated with fast neutrons
NASA Astrophysics Data System (ADS)
Izerrouken, M.; Benyahia, T.
2010-10-01
Colour centers formation in Al 2O 3 by reactor neutrons were investigated by optical measurements (absorption and photoluminescence). The irradiation's were performed at 40 °C, up to fast neutron ( E n > 1.2 MeV) fluence of 1.4 × 10 18 n cm -2. After irradiation the coloration of the sample increases with the neutron fluence and absorption band at about 203, 255, 300, 357 and 450 nm appear in the UV-visible spectrum. The evolution of each absorption bands as a function of fluence and annealing temperature is presented and discussed. The results indicate that at higher fluence and above 350 °C the F + center starts to aggregate to F center clusters (F 2, F 2+ and F22+). These aggregates disappear completely above 650 °C whereas the F and F + centers persist even after annealing at 900 °C. It is clear also from the results that the absorption band at 300 nm is due to the contribution of both F 2 center and interstitial Ali+ ions.
Kou, Guan Jun; Guo, Jing; Zuo, Xiu Li; Li, Chang Qing; Liu, Chao; Ji, Rui; Liu, Han; Wang, Xiao; Li, Yan Qing
2018-03-01
Celiac disease is a chronic inflammatory enteropathy with a symptom spectrum similar to that of irritable bowel syndrome (IBS). It is a common but largely undiagnosed condition in the Western countries. However, it is extremely rare among Chinese individuals, and few studies have investigated its prevalence in China. The aim was to determine the prevalence of celiac disease in patients with IBS who were diagnosed using the Rome III criteria in a single center of northern China. This was a single-center, prospective, controlled cohort study performed in Qilu Hospital involving 246 patients with IBS and 246 healthy controls. Blood samples were drawn to assess serum tissue transglutaminase immunoglobulin A (tTg-IgA). Patients with a positive or equivocal tTg-IgA (≥15 U/mL) were subjected to probe-based confocal laser endomicroscopy (pCLE) and duodenal biopsy to confirm celiac disease. Altogether 12 (4.9%) patients with IBS and two (0.8%) healthy controls were positive or equivocal for serum tTg-IgA. Of these, five patients with IBS underwent pCLE and a targeted biopsy; all were histopathologically found to have celiac disease, although one was eventually diagnosed with lymphoma. After implementation of a gluten-free diet, seven patients serologically positive for IBS showed clinical improvement, thus our study illustrated a minimum prevalence of 2.85% of celiac disease among patients with IBS in our center. Celiac disease is not rare in Chinese individuals, particularly among those with IBS. Therefore, it should receive higher attention in clinical practice in China. © 2018 Chinese Medical Association Shanghai Branch, Chinese Society of Gastroenterology, Renji Hospital Affiliated to Shanghai Jiaotong University School of Medicine and John Wiley & Sons Australia, Ltd.
Nanoscale magnetic imaging with a single nitrogen-vacancy center in diamond
NASA Astrophysics Data System (ADS)
Hong, Sungkun
Magnetic imaging has been playing central roles not only in fundamental sciences but also in engineering and industry. Their numerous applications can be found in various areas, ranging from chemical analysis and biomedical imaging to magnetic data storage technology. An outstanding problem is to develop new magnetic imaging techniques with improved spatial resolutions down to nanoscale, while maintaining their magnetic sensitivities. For instance, if detecting individual electron or nuclear spins with nanomter spatial resolution is possible, it would allow for direct imaging of chemical structures of complex molecules, which then could bring termendous impacts on biological sciences. While realization of such nanoscale magnetic imaging still remains challenging, nitrogen-vacancy (NV) defects in diamond have recently considered as promising magnetic field sensors, as their electron spins show exceptionally long coherence even at room temperature. This thesis presents experimental progress in realizing a nanoscale magnetic imaging apparatus with a single nitrogen-vacancy (NV) color center diamond. We first fabricated diamond nanopillar devices hosting single NV centers at their ends, and incorporated them to a custom-built atomic force microscope (AFM). Our devices showed unprecedented combination of magnetic field sensitivity and spatial resolution for scanning NV systems. We then used these devices to magnetically image a single isolated electronic spin with nanometer resolution, for the first time under ambient condition. We also extended our study to improve and generalize the application of the scanning NV magnetometer we developed. We first introduced magnetic field gradients from a strongly magnetized tip, and demonstrated that the spatial resolution can be further improved by spectrally distinguishing identical spins at different locations. In addition, we developed a method to synchronize the periodic motion of an AFM tip and pulsed microwave sequences controlling an NV spin. This scheme enabled employment of 'AC magnetic field sensing scheme' in imaging samples with static and spatially varying magnetizations.
Brauer, Brian C; Chen, Yang K; Fukami, Norio; Shah, Raj J
2009-09-01
When conventional ERCP methods fail because of periampullary or ductal obstruction, EUS-guided cholangiopancreatography (EUS-CP) may aid in pancreaticobiliary access. To report our experience when using single-operator EUS-CP. An academic tertiary-referral center. Consecutive patients undergoing EUS-CP were prospectively identified. These patients had undergone failed attempt(s) at therapeutic ERCP. A data sheet was used to record indications, reasons for failed ERCP, EUS-CP visualization of the duct of interest, transpapillary or transenteric intervention, clinical follow-up, and complications. Technical success was decompression of the duct of interest. Clinical success was resolution of jaundice or a > or = 50% reduction in pain or narcotics, as applicable. Between February 2003 and June 2007, EUS-CP was attempted in 20 patients (11 men, 9 women; mean [SD] age 58 +/- 14.9 years). Indications included jaundice (n = 8), biliary stones (n = 3), chronic pancreatitis (n = 6), acute pancreatitis (n = 2), and papillary stenosis (n = 1). Reasons for failed ERCP included periampullary mass (n = 8), intradiverticular papillae (n = 4), and pancreatic duct (PD) stricture (n = 7) or stone (n = 1). Technical success was achieved in 18 of 20 patients (90%). Biliary decompression was obtained in 11 of 12 patients (92%) (7 transpapillary and 4 transenteric-transcholedochal). Pancreatic decompression was obtained in 7 of 8 patients (88%) (3 transpapillary, 4 transgastric). On follow-up, clinical improvement was noted in 15 of 20 patients (70%). For treatment of pain associated with chronic pancreatitis, pain scores decreased by a mean of 1.75 (P = .18). Complications (in 2 of 20 [10%]) included perforation (n = 1) and respiratory failure (n = 1). A single-center nonrandomized observational study with a small patient population. At our academic referral center, single-operator EUS-CP provided decompression of obstructed ducts and may be performed after a failed attempt at conventional ERCP during the same endoscopic session.
Edinburgh, Laurel; Pape-Blabolil, Julie; Harpin, Scott B; Saewyc, Elizabeth
2014-09-01
The aim of this study was to describe contextual events, abuse experiences, and disclosure processes of adolescents who presented to a hospital-based Child Advocacy Center for medical evaluation and evidentiary collection as indicated after experiencing multiple perpetrator rape during a single event (n=32) and to compare these findings to a group of single perpetrator sexual assaults (n=534). This study used a retrospective mixed-methods design with in-depth, forensic interviews and complete physical examinations of gang-raped adolescents. Patients ranged from 12 to 17 years (M=14 years). Girls who experienced multiple perpetrator rape during a single event were more likely to have run away, to have drunk alcohol in the past month, and to have participated in binge drinking in the past 2 weeks. Acute presentation of these victims were rare but 30% had hymenal transections and 38% had sexually transmitted infections (STIs). Forensic interviews revealed alcohol was a common weapon used by offenders, and its use resulted in victims experiencing difficulty in remembering and reporting details for police investigation or physical and mental health care. Most victims were raped at parties they attended with people they thought they could trust, and they felt let down by witnesses who could have helped but did not intervene. Although relatively rare, multiple perpetrator rape during a single event is a type of severe sexual assault experience and has significant risks for deleterious health outcomes. These victims require health care by trained providers to diagnose physical findings, treat STIs, screen for trauma, and support victims. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.
Student Engagement at Two Single-Sex Colleges: Hampden-Sydney and Sweet Briar
ERIC Educational Resources Information Center
Simms, Edith L.
2010-01-01
Since the 1960s the higher educational system in the United States has steadily lost its single-sex colleges; and as of 2008 only 51 women's and four men's institutions remain (National Center for Educational Statistics, 2008). Many of the previous single-sex schools have admitted members of the opposite sex, giving in to the national trend of…
Using Meta-analyses for Comparative Effectiveness Research
Ruppar, Todd M.; Phillips, Lorraine J.; Chase, Jo-Ana D.
2012-01-01
Comparative effectiveness research seeks to identify the most effective interventions for particular patient populations. Meta-analysis is an especially valuable form of comparative effectiveness research because it emphasizes the magnitude of intervention effects rather than relying on tests of statistical significance among primary studies. Overall effects can be calculated for diverse clinical and patient-centered variables to determine the outcome patterns. Moderator analyses compare intervention characteristics among primary studies by determining if effect sizes vary among studies with different intervention characteristics. Intervention effectiveness can be linked to patient characteristics to provide evidence for patient-centered care. Moderator analyses often answer questions never posed by primary studies because neither multiple intervention characteristics nor populations are compared in single primary studies. Thus meta-analyses provide unique contributions to knowledge. Although meta-analysis is a powerful comparative effectiveness strategy, methodological challenges and limitations in primary research must be acknowledged to interpret findings. PMID:22789450
Almekhlafi, Mohammed A
2016-01-01
Numerous studies have reported a decline in stroke-related mortality in developed countries. To assess trends in one-year mortality following a stroke diagnosis in Saudi Arabia. Retrospective longitudinal cohort study. Single tertiary care center from 2010 through 2014. All patients admitted with a primary admitting diagnosis of stroke. Demographic data (age, gender, nationality), risk factor profile, stroke subtypes, in-hospital complications and mortality data as well as cause of death were collected for all patients. A multivariable logistic regression model was used to assess factors associated with one-year mortality following a stroke admission. One-year mortality. In 548 patients with a mean age of 62.9 years (SD 16.9), the most frequent vascular risk factors were hypertension (90.6%), diabetes (65.5%), and hyperlipidemia (27.2%). Hemorrhagic stroke was diagnosed in 9.9%. The overall mortality risk was 26.9%. Non-Saudis had a significantly higher one-year mortality risk compared with Saudis (25% vs. 16.8%, respectively; P=.025). The most frequently reported causes of mortality were neurological and related to the underlying stroke (32%), sepsis (30%), and cardiac or other organ dysfunction-related (each 9%) in addition to other etiologies (collectively 9.5%) such as pulmonary embolism or an underlying malignancy. Significant predictors in the multivariate model were age (P < .0001), non-Saudi nationality (OR 1.8, CI 95 1.1 to 2.9; P=.019), and hospital length of stay (OR 1.01, CI 95 1 to 1.004; P=.001). We observed no decline in stroke mortality in our center over the 5-year span. The establishment of stroke systems of care, use of thrombolytic agents, and opening of a stroke unit should play an important role in a decline in stroke mortality. Retrospective single center study. Mortality data were available only for patients who died in our hospital.
Theoretical and material studies on thin-film electroluminescent devices
NASA Technical Reports Server (NTRS)
Summers, C. J.; Brennan, K. F.
1986-01-01
Electroluminescent materials and device technology were assessed. The evaluation strongly suggests the need for a comprehensive theoretical and experimental study of both materials and device structures, particularly in the following areas: carrier generation and multiplication; radiative and nonradiative processes of luminescent centers; device modeling; new device concepts; and single crystal materials growth and characterization. Modeling of transport properties of hot electrons in ZnSe and the generation of device concepts were initiated.
Equity in Educational Finance and A Study of the Impact of Block Grants in a Selected State.
ERIC Educational Resources Information Center
Moody, Charles D., Sr.; Kearney, C. Philip
1984-01-01
The 1981 enactment of the Education Consolidation and Improvement Act Chapter 2 (ECIA-Chapter 2), which consolidated 28 separate categorical federal aid programs into a single block grant, has had policy and fiscal impacts in Michigan. Policy debate centers on the inherent tension between equity, particularly equity defined as equal treatment of…
Producing a functional eukaryotic messenger RNA (mRNA) requires the coordinated activity of several large protein complexes to initiate transcription, elongate nascent transcripts, splice together exons, and cleave and polyadenylate the 3’ end. Kinetic competition between these various processes has been proposed to regulate mRNA maturation, but this model could lead to
ERIC Educational Resources Information Center
Gilstrap, Donald E.
2010-01-01
A literature review revealed a lack of academic research related to cultural dynamics within organizations that influence information technology investments. The goal of this single descriptive case study of a for profit international company was to examine one area of cultural influence on investments. The aim was to gain an understanding of…
ERIC Educational Resources Information Center
Zambo, Janeen-Marie Harvey
2017-01-01
Educational equity is a major component to solving the achievement gap in public education. Prior research on educational equity has largely centered on the development of multicultural education and critical race theoretical approaches, with some studies considering how these theories are best incorporated into teacher preparation programs.…
ERIC Educational Resources Information Center
Stieha, Vicki
2010-01-01
This single case study takes a phenomenological approach using the voice centered analysis to analyze qualitative interview data so that the voice of this first-generation college student is brought forward. It is a poignant voice filled with conflicting emotional responses to the desire for college success, for family stability, for meaningful…
ERIC Educational Resources Information Center
Swan, Karrie L.
2011-01-01
A growing disparity between the mental health needs of children and their lack of treatment served as the basis of this study. To address this existent gap, I proposed that child-centered play therapy (CCPT), a holistic treatment that fosters children's emotional, developmental, and social growth would serve as a viable treatment. The purpose of…
ERIC Educational Resources Information Center
Simmons, Sandra F.; Bertrand, Rosanna; Shier, Victoria; Sweetland, Rebecca; Moore, Therese J.; Hurd, Donna T.; Schnelle, John F.
2007-01-01
Purpose: The Centers for Medicare and Medicaid Services and the Agency for Healthcare Research and Quality sponsored a nationwide study to evaluate the federal paid feeding assistant (PFA) regulation that allows nursing homes to hire single-task workers to provide feeding assistance to nursing home residents. Organizers designed the PFA regulation…
ERIC Educational Resources Information Center
Rector, Robert; Johnson, Kirk A.; Fagan, Patrick F.
This study uses National Longitudinal Survey of Youth (NLSY) data to analyze differences in black and white child poverty. The NLSY documents family income and underlying conditions such as employment, educational attainment, welfare use, and marriage or divorce. This analysis examines: time in poverty, time on welfare, time in a single parent…
Closed-Form 3-D Localization for Single Source in Uniform Circular Array with a Center Sensor
NASA Astrophysics Data System (ADS)
Bae, Eun-Hyon; Lee, Kyun-Kyung
A novel closed-form algorithm is presented for estimating the 3-D location (azimuth angle, elevation angle, and range) of a single source in a uniform circular array (UCA) with a center sensor. Based on the centrosymmetry of the UCA and noncircularity of the source, the proposed algorithm decouples and estimates the 2-D direction of arrival (DOA), i.e. azimuth and elevation angles, and then estimates the range of the source. Notwithstanding a low computational complexity, the proposed algorithm provides an estimation performance close to that of the benchmark estimator 3-D MUSIC.
NASA Astrophysics Data System (ADS)
Delord, T.; Nicolas, L.; Chassagneux, Y.; Hétet, G.
2017-12-01
A scheme for strong coupling between a single atomic spin and the rotational mode of levitating nanoparticles is proposed. The idea is based on spin readout of nitrogen-vacancy centers embedded in aspherical nanodiamonds levitating in an ion trap. We show that the asymmetry of the diamond induces a rotational confinement in the ion trap. Using a weak homogeneous magnetic field and a strong microwave driving we then demonstrate that the spin of the nitrogen-vacancy center can be strongly coupled to the rotational mode of the diamond.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xiao, X.; Liang, J. H.; Chen, B. L.
2015-07-28
Face-centered-cubic cobalt films are epitaxially grown on insulating LaAlO{sub 3}(001) substrates by molecular beam epitaxy. Transport measurements are conducted in different current directions relative to the crystal axes. We find that the temperature dependent anisotropic magnetoresistance ratio strongly depends on the current direction. However, the anomalous Hall effect shows isotropic behavior independent of the current direction. Our results demonstrate the interplay between the current direction and the crystalline lattice in single-crystalline ferromagnetic films. A phenomenological analysis is presented to interpret the experimental data.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Phuthong, Witchukorn; Huang, Zubin; Wittkopp, Tyler M.
To investigate the dynamics of photosynthetic pigment-protein complexes in vascular plants at high resolution in an aqueous environment, membrane-protruding oxygen-evolving complexes (OECs) associated with photosystem II (PSII) on spinach ( Spinacia oleracea) grana membranes were examined using contact mode atomic force microscopy. This study represents, to our knowledge, the first use of atomic force microscopy to distinguish the putative large extrinsic loop of Photosystem II CP47 reaction center protein (CP47) from the putative oxygen-evolving enhancer proteins 1, 2, and 3 (PsbO, PsbP, and PsbQ) and large extrinsic loop of Photosystem II CP43 reaction center protein (CP43) in the PSII-OEC extrinsicmore » domains of grana membranes under conditions resulting in the disordered arrangement of PSII-OEC particles. Moreover, we observed uncharacterized membrane particles that, based on their physical characteristics and electrophoretic analysis of the polypeptides associated with the grana samples, are hypothesized to be a domain of photosystem I that protrudes from the stromal face of single thylakoid bilayers. Furthermore, our results are interpreted in the context of the results of others that were obtained using cryo-electron microscopy (and single particle analysis), negative staining and freeze-fracture electron microscopy, as well as previous atomic force microscopy studies.« less
Son, Joohyung; Bae, Miju; Chung, Sung Woon; Lee, Chung Won; Huh, Up; Song, Seunghwan
2017-12-01
The inferior vena cava filter (IVCF) is very effective for preventing pulmonary embolism in patients who cannot undergo anticoagulation therapy. However, if a filter is placed in the body permanently, it may lead to other complications. A retrospective study was performed of 159 patients who underwent retrievable Cook Celect IVCF implantation between January 2007 and April 2015 at a single center. Baseline characteristics, indications, and complications caused by the filter were investigated. The most common underlying disease of patients receiving the filter was cancer (24.3%). Venous thrombolysis or thrombectomy was the most common indication for IVCF insertion in this study (47.2%). The most common complication was inferior vena cava penetration, the risk of which increased the longer the filter remained in the body (p=0.032, Exp(B)=1.004). If the patient is able to retry anticoagulation therapy and the filter is no longer needed, the filter should be removed, even if a long time has elapsed since implantation. If the filter cannot be removed, it is recommended that follow-up computed tomography be performed regularly to monitor the progress of venous thromboembolisms as well as any filter-related complications.
NASA Astrophysics Data System (ADS)
Rivas Rojas, P. C.; Tancredi, P.; Moscoso Londoño, O.; Knobel, M.; Socolovsky, L. M.
2018-04-01
Single and fixed size core, core-shell nanoparticles of iron oxides coated with a silica layer of tunable thickness were prepared by chemical routes, aiming to generate a frame of study of magnetic nanoparticles with controlled dipolar interactions. The batch of iron oxides nanoparticles of 4.5 nm radii, were employed as cores for all the coated samples. The latter was obtained via thermal decomposition of organic precursors, resulting on nanoparticles covered with an organic layer that was subsequently used to promote the ligand exchange in the inverse microemulsion process, employed to coat each nanoparticle with silica. The amount of precursor and times of reaction was varied to obtain different silica shell thicknesses, ranging from 0.5 nm to 19 nm. The formation of the desired structures was corroborated by TEM and SAXS measurements, the core single-phase spinel structure was confirmed by XRD, and superparamagnetic features with gradual change related to dipolar interaction effects were obtained by the study of the applied field and temperature dependence of the magnetization. To illustrate that dipolar interactions are consistently controlled, the main magnetic properties are presented and analyzed as a function of center to center minimum distance between the magnetic cores.
Automatic Indexing for Content Analysis of Whale Recordings and XML Representation
NASA Astrophysics Data System (ADS)
Bénard, Frédéric; Glotin, Hervé
2010-12-01
This paper focuses on the robust indexing of sperm whale hydrophone recordings based on a set of features extracted from a real-time passive underwater acoustic tracking algorithm for multiple whales using four hydrophones. Acoustic localization permits the study of whale behavior in deep water without interfering with the environment. Given the position coordinates, we are able to generate different features such as the speed, energy of the clicks, Inter-Click-Interval (ICI), and so on. These features allow to construct different markers which allow us to index and structure the audio files. Thus, the behavior study is facilitated by choosing and accessing the corresponding index in the audio file. The complete indexing algorithm is processed on real data from the NUWC (Naval Undersea Warfare Center of the US Navy) and the AUTEC (Atlantic Undersea Test & Evaluation Center-Bahamas). Our model is validated by similar results from the US Navy (NUWC) and SOEST (School of Ocean and Earth Science and Technology) Hawaii university labs in a single whale case. Finally, as an illustration, we index a single whale sound file using the extracted whale's features provided by the tracking, and we present an example of an XML script structuring it.
NASA Astrophysics Data System (ADS)
Thomas, John Meurig
2008-05-01
Predominantly this article deals with the question of how to design new solid catalysts for a variety of industrial and laboratory-orientated purposes. A generally applicable strategy, illustrated by numerous examples, is made possible based on the use of nanoporous materials on to the (high-area) inner surfaces of which well-defined (experimentally and computationally) active centers are placed in a spatially separated fashion. Such single-site catalysts, which have much in common with metal-centered homogenous catalysts and enzymes, enable a wide range of new catalysts to be designed for a variety of selective oxidations, hydrogenations, hydrations and hydrodewaxing, and other reactions that the "greening" of industrial processes demand. Examples are given of new shape-selective, regio-selective, and enantioselective catalysts, many of which operate under mild, environmentally benign conditions. Also considered are some of the reasons why detailed studies of adsorption and stoichiometric reactions at single-crystal surfaces have, disappointingly, not hitherto paved the way to the design and production of many new heterogenous catalysts. Recent work of a theoretical and high-throughout nature, allied to some experimental studies of well-chosen model systems, holds promise for the identification of new catalysts for simple, but industrially important reactions.
receive a rebate of 75% of equipment cost, up to $2,500 for single port stations and $3,500 for multi-port installation cost, up to $30,000 for single port stations and $42,000 for multi-port stations. To receive a
NASA Technical Reports Server (NTRS)
Lord, Kenneth; Woodyard, James R.
2002-01-01
The effect of 40 keV electron irradiation on a-Si:H p-i-n single-junction solar cells was investigated using measured and simulated dark J-V characteristics. EPRI-AMPS and PC-1D simulators were explored for use in the studies. The EPRI-AMPS simulator was employed and simulator parameters selected to produce agreement with measured J-V characteristics. Three current mechanisms were evident in the measured dark J-V characteristics after electron irradiation, namely, injection, shunting and a term of the form CV(sup m). Using a single discrete defect state level at the center of the band gap, good agreement was achieved between measured and simulated J-V characteristics in the forward-bias voltage region where the dark current density was dominated by injection. The current mechanism of the form CV(sup m) was removed by annealing for two hours at 140 C. Subsequent irradiation restored the CV(sup m) current mechanism and it was removed by a second anneal. Some evidence of the CV(sup m) term is present in device simulations with a higher level of discrete density of states located at the center of the bandgap.
Narasimhan, Gomathy; Safwan, Mohamed; Kota, Venugopal; Reddy, Mettu S; Bharathan, Anand; Dabora, Abderrhaim; Kaliamoorthy, Ilankumaran; Kanagavelu, Rathnavel G; Srinivasan, Vijaya; Rela, Mohamed
2016-06-01
Live donor liver transplantation is the predominant form of liver transplantation in India and in most Asian countries. Donor outcome reports are an important source of information to be shared with prospective donors at the time of informed consent. This is the first donor outcome series from India. Analysis of donor characteristics and morbidity of 275 live donors from a single large volume center is documented. Two hundred seventy-five patients donated from November 2009 to October 2014, 144 were women and 131 were men, 180 donated to adults and 95 donated to children. Right lobe donors were majority at 62.2% followed by left lateral segment 28%. Two thirds of the live donors did not have any morbidity; 114 complications were encountered in 85 patients. The complications were graded as per Clavien 5 tier grading and major morbidity (grade III b, grade IV grade V) was 4.36%. Postoperative biliary complication was seen in 3 donors. This large single-center study is the first donor outcome report from India, and the results are comparable to other published donor series. Documentation and regular audit of donor outcomes is important to help improve the safety of donor hepatectomy and to provide a database for informed consent of prospective donors.
1992-12-30
34 Family Policy," December 30, 1988 o / (b) DoD Directive 4001.1, "Installation Management ,, September 4, 1986 (c) DoD 4165.63-M, "DoD Housing Management ... managing the competing demands of the military mission and the family . They shall provide the information and family services necessary to support single...effectiveness of Family Centers. The evaluation system shall include: (1) A management information report to allow Family Centers to reflect actual workloads
Fukushima, Norihide; Tatsumi, Eisuke; Seguchi, Osamu; Takewa, Yoshiaki; Hamasaki, Toshimitsu; Onda, Kaori; Yamamoto, Haruko; Hayashi, Teruyuki; Fujita, Tomoyuki; Kobayashi, Junjiro
2018-06-08
The management of heart failure patients presenting in a moribund state remains challenging, despite significant advances in the field of ventricular assist systems. Bridge to decision involves using temporary devices to stabilize the hemodynamic state of such patients while further assessment is performed and a decision can be made regarding patient management. The purpose of this study (NCVC-BTD_01, National Cerebral and Cardiovascular Center-Bridge to Dicision_01) is to assess the safety and effectiveness of the newly developed extracorporeal continuous-flow ventricular assist system employing a disposable centrifugal pump with a hydrodynamically levitated bearing (BR16010) use as a bridge-to-decision therapy for patients with severe heart failure or refractory cardiogenic shock. NCVC-BTD_01 is a single-center, single-arm, open-label, exploratory, medical device, investigator-initiated clinical study. It is conducted at the National Cerebral and Cardiovascular Center in Japan. A total of nine patients will be enrolled in the study. The study was planned using Simon's minimax two-stage phase design. The primary endpoint is a composite of survival free of device-related serious adverse events and complications during device support. For left ventricular assistance, withdrawal of a trial device due to cardiac function recovery or exchange to other ventricular assist devices (VADs) for the purpose of bridge to transplantation (BTT) during 30 days after implantation will be considered study successes. For right ventricular assistance, withdrawal of tal device due to right ventricular function recovery within 30 days after implantation will be considered a study success. Secondary objectives include changes in brain natriuretic peptide levels (7 days after implantation of a trial device and the day of withdrawal of a trial device), period of mechanical ventricular support, changes in left ventricular ejection fraction (7 days after implantation of a trial device and the day of withdrawal of a trial device), and changes in left ventricular diastolic dimension (7 days after implantation of a trial device and the day of withdrawal of a trial device). We will disseminate the findings through regional, national, and international conferences and through peer-reviewed journals. UMIN Clinical Trials Registry (UMIN-CTR; R000033243) registered on 8 September 2017.
Improvement of the air quality in student health centers with chlorine dioxide.
Hsu, Ching-Shan; Huang, Da-Ji; Lu, Ming-Chun
2010-04-01
This study aims to monitor bioaerosol levels of a local campus of a student health center in Taiwan and then to perform disinfection by applying chlorine dioxide. First, air samples were taken and evaluated in the six areas of the center. The average background bioaerosol levels were 714 +/- 1706 CFU/m(3) for bacterium and 802 +/- 633 CFU/m(3) for fungi. Then, chlorine dioxide was applied through three different procedures: single, multiple and regular disinfections. The results indicated that both multiple and regular disinfections can achieve efficiency levels higher than 59.0%. The regression analysis on bioaerosol levels showed that the number of people present correlating to the number of persons entering the room per door-opening, had a correlation of p < 0.05. Utilizing this analysis result, an empirical model was developed to predict indoor bioaerosol concentrations. It can be inferred that for indoor human activity of health centers, regular disinfection is a very effective process.
A review of colour center and nanostructure creation in LiF under heavy ion irradiation
NASA Astrophysics Data System (ADS)
Schwartz, K.; Maniks, J.; Manika, I.
2015-09-01
A study of radiation damage in LiF crystals under irradiation with MeV-GeV energy ions, from 12C to 238U, at temperatures varying from 8 to 300 K, depending on the ion energy, energy loss and irradiation temperature, is presented. For light ions (12C, 14N) at low fluences, it is mainly color centers that are created. Increasing the fluence leads to the overlapping of tracks and the creation of more complex color centers, defect aggregates and dislocations. For ions with an energy loss above a threshold value (dE/dx = 10 keV nm-1) the tracks exhibit a central core damage region with a radius of 1-2 nm, surrounded by an extended halo which mainly contains single color centers. In this case, ion-induced nanostructuring is observed. Novel effects of radiation damage creation under ion irradiation at 8 K are observed. The role of energy loss and irradiation temperature in damage creation is discussed.
ERIC Educational Resources Information Center
PEPNet, 2009
2009-01-01
PEPNet's "Perspectives" is the collaborative newsletter of the four PEPNet regional centers. This newsletter combines each centers' individual strengths into a single resource that can be used on a national level. PEPNet's mission is to improve transition services and educational access for students who are deaf or hard of hearing, including those…
Yin, Yi; Zech, M; Williams, T L; Wang, X F; Wu, G; Chen, X H; Hoffman, J E
2009-03-06
We present an atomic resolution scanning tunneling spectroscopy study of superconducting BaFe1.8Co0.2As2 single crystals in magnetic fields up to 9 T. At zero field, a single gap with coherence peaks at Delta=6.25 meV is observed in the density of states. At 9 and 6 T, we image a disordered vortex lattice, consistent with isotropic, single flux quantum vortices. Vortex locations are uncorrelated with strong-scattering surface impurities, demonstrating bulk pinning. The vortex-induced subgap density of states fits an exponential decay from the vortex center, from which we extract a coherence length xi=27.6+/-2.9 A, corresponding to an upper critical field Hc2=43 T.
Theoretical study on the photocatalytic properties of graphene oxide with single Au atom adsorption
NASA Astrophysics Data System (ADS)
Ju, Lin; Dai, Ying; Wei, Wei; Li, Mengmeng; Jin, Cui; Huang, Baibiao
2018-03-01
The photocatalytic properties of graphene oxide (GO) with single Au atom adsorption are studied via the first-principles calculations based on the density functional theory. The present study addresses the origin of enhancement in photocatalytic efficiency of GO derived from single Au atom depositing. Compared with the clean one, the work function of the single Au atom adsorbed GO is lowered due to the charge transfer from Au to GO, indicating enhanced surface activity. The Au atom plays as an electron trapping center and a mediating role in charge transfer from photon excited GO to target species. The photogenerated electron-hole pairs can be separated effectively. For the GO configuration with atomic Au dispersion, there are some states introduced in the band gap, which are predominantly composed of Au 6s states. Through the in-gap state, the photo-generated electron transfer from the valence band of clean GO to the conductive band more easily. In addition, the reduction of the gap in the system is also presented in the current work, which indicates that the single Au atom adsorption improves light absorption for the GO based photocatalyst. These theoretical results are valuable for the future applications of GO materials as photocatalyst for water splitting.
Photo-conductance of a single Quantum Dot
NASA Astrophysics Data System (ADS)
Zimmers, Alexandre; Wang, Hongyue; Lhuillier, Emmanuel; Yu, Qian; Dubertret, Benoit; Aubin, Herve; Ulysse, Christian; LPEM Collaboration
One promising strategy for the development of nanoscale resonant spin sensors is to measure the spin-dependent photo-current in Quantum Dots (QDots) containing spin-dependent recombination centers. To reach single spin sensitivity will require measurements of the photo-conductance of single QDots. We present here an experimental study of the conductance and photo-conductance of single HgSe QDots as function of drain and gate voltage. The evolution of the differential conductance dI/dV spectrum with the gate voltage demonstrates that single HgSe QDots are forming the junction. The amplitude of the gap measured in the differential conductance spectrum changes with the occupation level. A large inter-band gap, 0,85eV, is observed for the empty QDot, a smaller intra-band gap 0,25eV is observed for the doubly occupied QDot. These gap energies are consistent with the values extracted from the optical absorption spectrum. Upon illuminating the QDot junction, we show that the photo-conductive signal produced by this single QDot can be measured with a simple demodulation method. ANR Grant ''QUANTICON'' 10-0409-01 / DIM Nano-K / Chinese Scholarship Council.
Critical examination of the uniformity requirements for single-photon emission computed tomography.
O'Connor, M K; Vermeersch, C
1991-01-01
It is generally recognized that single-photon emission computed tomography (SPECT) imposes very stringent requirements on gamma camera uniformity to prevent the occurrence of ring artifacts. The purpose of this study was to examine the relationship between nonuniformities in the planar data and the magnitude of the consequential ring artifacts in the transaxial data, and how the perception of these artifacts is influenced by factors such as reconstruction matrix size, reconstruction filter, and image noise. The study indicates that the relationship between ring artifact magnitude and image noise is essentially independent of the acquisition or reconstruction matrix sizes, but is strongly dependent upon the type of smoothing filter applied during the reconstruction process. Furthermore, the degree to which a ring artifact can be perceived above image noise is dependent on the size and location of the nonuniformity in the planar data, with small nonuniformities (1-2 pixels wide) close to the center of rotation being less perceptible than those further out (8-20 pixels). Small defects or nonuniformities close to the center of rotation are thought to cause the greatest potential corruption to tomographic data. The study indicates that such may not be the case. Hence the uniformity requirements for SPECT may be less demanding than was previously thought.
Falls, Roman; Seman, Michael; Braat, Sabine; Sortino, Joshua; Allen, Jason D; Neil, Christopher J
2017-08-08
Acute heart failure (AHF) is a frequent reason for hospitalization worldwide and effective treatment options are limited. It is known that AHF is a condition characterized by impaired vasorelaxation, together with reduced nitric oxide (NO) bioavailability, an endogenous vasodilatory compound. Supplementation of inorganic sodium nitrate (NaNO 3 ) is an indirect dietary source of NO, through bioconversion. It is proposed that oral sodium nitrate will favorably affect levels of circulating NO precursors (nitrate and nitrite) in AHF patients, resulting in reduced systemic vascular resistance, without significant hypotension. We propose a single center, randomized, double-blind, placebo-controlled pilot trial, evaluating the feasibility of sodium nitrate as a treatment for AHF. The primary hypothesis that sodium nitrate treatment will result in increased systemic levels of nitric oxide pre-cursors (nitrate and nitrite) in plasma, in parallel with improved vasorelaxation, as assessed by non-invasively derived systemic vascular resistance index. Additional surrogate measures relevant to the known pathophysiology of AHF will be obtained in order to assess clinical effect on dyspnea and renal function. The results of this study will provide evidence of the feasibility of this novel approach and will be of interest to the heart failure community. This trial may inform a larger study.
NASA Astrophysics Data System (ADS)
Layana, S. R.; Saritha, S. R.; Anitha, L.; Sithambaresan, M.; Sudarsanakumar, M. R.; Suma, S.
2018-04-01
A novel O,N,O donor salicylaldehyde-N4-phenylsemicarbazone, (H2L) has been synthesized and physicochemically characterized. Detailed structural studies of H2L using single crystal X-ray diffraction technique reveals the existence of intra and inter molecular hydrogen bonding interactions, which provide extra stability to the molecule. We have successfully synthesized a binuclear copper(II) complex, [Cu2(HL)2(NO3)(H2O)2]NO3 with phenoxy bridging between the two copper centers. The complex was characterized by elemental analysis, magnetic susceptibility and conductivity measurements, FT-IR, UV-Visible, mass and EPR spectral methods. The grown crystals of the copper complex were employed for the single crystal X-ray diffraction studies. The complex possesses geometrically different metal centers, in which the ligand coordinates through ketoamide oxygen, azomethine nitrogen and deprotonated phenoxy oxygen. The extensive intermolecular hydrogen bonding interactions of the coordinated and the lattice nitrate groups interconnect the complex units to form a 2D supramolecular assembly. The ESI mass spectrum substantiates the existence of 1:1 complex. The g values obtained from the EPR spectrum in frozen DMF suggest dx2 -y2 ground state for the unpaired electron.
Ma, Jianying; Hou, Lei; Qian, Juying; Ge, Lei; Zhang, Feng; Chang, Shufu; Xu, Rende; Qin, Qing; Ge, Junbo
2017-10-01
The monorail Guidezilla guide extension catheter was designed to provide additional backup and facilitate device delivery in percutaneous coronary intervention (PCI) for complex coronary anatomy such as chronic total occlusion (CTO), extreme vessel tortuosity, diseased bypass grafts, and anomalous coronary arteries, among others.The present retrospective, single-center study included 188 consecutive patients who underwent PCI using the Guidezilla catheter from March 2015 to August 2016. Study outcomes were rates of target lesion crossing success, procedural success, and complications.The Guidezilla catheter was used most commonly in PCI of CTOs (45%) and heavy proximal calcification (37%), followed by tortuosity (10%), previously deployed proximal stents (4%), and coronary artery anomaly (4%). The right coronary artery (48%) was most commonly intervened followed by the left ascending (35%) and left circumflex (17%) arteries. Rates of target lesion crossing success and procedural success were both 99%, with one device-related periprocedural complication, namely proximal vessel dissection secondary to deep insertion which was successfully treated with stent implantation. Ninety percent of PCI were performed and completed successfully by radial access.In a single center with experienced operators, the use of the Guidezilla guide extension catheter in PCI of complex coronary anatomy performed mostly via radial artery access appeared safe and efficacious, and greatly facilitated device delivery.
Ma, Jianying; Hou, Lei; Qian, Juying; Ge, Lei; Zhang, Feng; Chang, Shufu; Xu, Rende; Qin, Qing; Ge, Junbo
2017-01-01
Abstract The monorail GuidezillaTM guide extension catheter was designed to provide additional backup and facilitate device delivery in percutaneous coronary intervention (PCI) for complex coronary anatomy such as chronic total occlusion (CTO), extreme vessel tortuosity, diseased bypass grafts, and anomalous coronary arteries, among others. The present retrospective, single-center study included 188 consecutive patients who underwent PCI using the Guidezilla catheter from March 2015 to August 2016. Study outcomes were rates of target lesion crossing success, procedural success, and complications. The Guidezilla catheter was used most commonly in PCI of CTOs (45%) and heavy proximal calcification (37%), followed by tortuosity (10%), previously deployed proximal stents (4%), and coronary artery anomaly (4%). The right coronary artery (48%) was most commonly intervened followed by the left ascending (35%) and left circumflex (17%) arteries. Rates of target lesion crossing success and procedural success were both 99%, with one device-related periprocedural complication, namely proximal vessel dissection secondary to deep insertion which was successfully treated with stent implantation. Ninety percent of PCI were performed and completed successfully by radial access. In a single center with experienced operators, the use of the Guidezilla guide extension catheter in PCI of complex coronary anatomy performed mostly via radial artery access appeared safe and efficacious, and greatly facilitated device delivery. PMID:28984768
Sunflower domestication alleles support single domestication center in eastern North America
Blackman, Benjamin K.; Scascitelli, Moira; Kane, Nolan C.; Luton, Harry H.; Rasmussen, David A.; Bye, Robert A.; Lentz, David L.; Rieseberg, Loren H.
2011-01-01
Phylogenetic analyses of genes with demonstrated involvement in evolutionary transitions can be an important means of resolving conflicting hypotheses about evolutionary history or process. In sunflower, two genes have previously been shown to have experienced selective sweeps during its early domestication. In the present study, we identified a third candidate early domestication gene and conducted haplotype analyses of all three genes to address a recent, controversial hypothesis about the origin of cultivated sunflower. Although the scientific consensus had long been that sunflower was domesticated once in eastern North America, the discovery of pre-Columbian sunflower remains at archaeological sites in Mexico led to the proposal of a second domestication center in southern Mexico. Previous molecular studies with neutral markers were consistent with the former hypothesis. However, only two indigenous Mexican cultivars were included in these studies, and their provenance and genetic purity have been questioned. Therefore, we sequenced regions of the three candidate domestication genes containing SNPs diagnostic for domestication from large, newly collected samples of Mexican sunflower landraces and Mexican wild populations from a broad geographic range. The new germplasm also was genotyped for 12 microsatellite loci. Our evidence from multiple evolutionarily important loci and from neutral markers supports a single domestication event for extant cultivated sunflower in eastern North America. PMID:21844335
Aghdassi, Ali; Christoph, Agnes; Dombrowski, Frank; Döring, Paula; Barth, Christoph; Christoph, Jan; Lerch, Markus M; Simon, Peter
2018-06-05
Gastrointestinal stromal tumors (GISTs) are rare malignancies but the most common mesenchymal tumors of the digestive tract. Recent advances in diagnostic imaging and an increasing incidence will confront us more frequently with stromal tumors. This single center study aimed to characterize GIST patients in terms of tumor location, clinical presentation, metastasis formation, as well as associated secondary malignancies. In a retrospective study, 104 patients with a histologically confirmed diagnosis of GIST, collected between 1993 and 2011, were characterized for several clinical features. The most common GIST location was the stomach (67.6%) followed by the small intestine (16.2%). Gastrointestinal bleeding (55.8%) and abdominal pain (38.5%) were the most frequently reported symptoms whereas about one-third of patients remained clinically asymptomatic (31.6%); 14.4% of patients had either synchronous or metachronous metastases and there was a significant prevalence also in the low risk group. The proportion of secondary malignant associated neoplasms was 31% in our GIST cohort, among which gastrointestinal, genitourinary tumors, and breast cancer were the most prevalent. There was a considerable risk for metastasis formation and the development of secondary neoplasias that should encourage discussion about the appropriate surveillance strategy after surgery for GIST. © 2018 S. Karger AG, Basel.
Review and Analysis of Publication Trends over Three Decades in Three High Impact Medicine Journals.
Ivanov, Alexander; Kaczkowska, Beata A; Khan, Saadat A; Ho, Jean; Tavakol, Morteza; Prasad, Ashok; Bhumireddy, Geetha; Beall, Allan F; Klem, Igor; Mehta, Parag; Briggs, William M; Sacchi, Terrence J; Heitner, John F
2017-01-01
Over the past three decades, industry sponsored research expanded in the United States. Financial incentives can lead to potential conflicts of interest (COI) resulting in underreporting of negative study results. We hypothesized that over the three decades, there would be an increase in: a) reporting of conflict of interest and source of funding; b) percentage of randomized control trials c) number of patients per study and d) industry funding. Original articles published in three calendar years (1988, 1998, and 2008) in The Lancet, New England Journal of Medicine and Journal of American Medical Association were collected. Studies were reviewed and investigational design categorized as prospective and retrospective clinical trials. Prospective trials were categorized into randomized or non-randomized and single-center or multi-center trials. Retrospective trials were categorized as registries, meta-analyses and other studies, mostly comprising of case reports or series. Study outcomes were categorized as positive or negative depending on whether the pre-specified hypothesis was met. Financial disclosures were researched for financial relationships and profit status, and accordingly categorized as government, non-profit or industry sponsored. Studies were assessed for reporting COI. 1,671 original articles were included in this analysis. Total number of published studies decreased by 17% from 1988 to 2008. Over 20 year period, the proportion of prospective randomized trials increased from 22 to 46% (p < 0.0001); whereas the proportion of prospective non-randomized trials decreased from 59% to 27% (p < 0.001). There was an increase in the percentage of prospective randomized multi-center trials from 11% to 41% (p < 0.001). Conversely, there was a reduction in non-randomized single-center trials from 47% to 10% (p < 0.001). Proportion of government funded studies remained constant, whereas industry funded studies more than doubled (17% to 40%; p < 0.0001). The number of studies with negative results more than doubled (10% to 22%; p<0.0001). While lack of funding disclosure decreased from 35% to 7%, COI reporting increased from 2% to 84% (p < 0.0001). Improved reporting of COI, clarity in financial sponsorship, increased publication of negative results in the setting of larger and better designed clinical trials represents a positive step forward in the scientific publications, despite the higher percentage of industry funded studies.
Lushaj, Entela B; Schreiner, Athanasia; Jonuzi, Besa; Badami, Abbasali; DeOliveira, Nilto; Lozonschi, Lucian
2016-05-17
We retrospectively assessed the outcomes after coronary revascularization at a single Veterans Affairs Medical Center when a strategy of assigning higher risk patients to off-pump coronary artery bypass grafting (CABG) was employed. Over a 5 year period all consecutive patients that underwent CABG at our VA Medical Center were assigned to a surgeon who either performs the CABG exclusively off-pump or to one who performed the CABG on-pump. The higher risk patients were assigned preferentially for off-pump revascularization. VASQIP (VA Hospitals Surgical Quality Improvement Program) data between 10/2007 and 12/2012 were retrospectively reviewed at our VA Medical Center and the short term outcomes were assessed. A total of 252 consecutive patients underwent off-pump CABG (n = 170) and on-pump CABG (n = 82). There were significantly more patients with low LVEF (<45 %; p = 0.008) and cerebrovascular disease in the off-pump group (p = 0.024). The number of patients smoking at the time of surgery was significantly higher in the off-pump group (p = 0.002) as well. The 30-day composite morbidity and mortality was 6 % for all CABG patients and significantly lower with off-pump vs. on-pump CABG (3.5 % vs. 11 %; p = 0.019). There were no conversions from off-pump to on-pump surgery. A selective strategy to direct higher risk patients towards an off-pump revascularization yielded favorable outcomes in an unselected veteran population treated at a single VA Medical Center over a 5 year period.
Health center financial performance: national trends and state variation, 1998-2004.
Shi, Leiyu; Collins, Patricia B; Aaron, Kaytura Felix; Watters, Vanessa; Shah, Leslie Greenblat
2007-01-01
For four decades, health centers have provided quality, cost-effective primary healthcare to underserved populations. Using the Uniform Data System, this study analyzes national trends in health center patients, providers, and financial performance for 1998-2004, and state-specific data for 2004. Between 1998 and 2004, health centers served increasing numbers of underserved patients, which included patients who were uninsured or on Medicaid, minorities, and patients at or below poverty level. Even though the number of health center providers and patients increased, patient-to-provider ratios did not change significantly. Medicaid remained the single largest source of health center revenue, accounting for 36.4 percent of total revenue in 2004. Compared with Medicare, private insurance, and self-pay, Medicaid consistently reimbursed health centers at the highest rate per patient. Federal and nonfederal grants to support care for the uninsured as well as enabling services such as transportation, translation, and other support systems is one of many important sources of revenue. Financial challenges for health centers included increasing costs and varied or declining rates of reimbursement for services rendered. However, health centers became more self-sufficient over time, average net revenues increased, and operating margins were predominantly positive. Data on individual states, with different numbers and types of health centers, varied widely in all of these categories. In conclusion, health centers rely on federal and nonfederal grant support in concert with the Medicaid program as major funding sources and continued financial stability will be contingent upon health centers' ability to balance revenues with the cost of managing the vulnerable populations that they serve.
Prevalence of malnutrition in hemodialysis patients: A single-center study in Palestine.
Rezeq, Hinar Abu; Khdair, Lubna N; Hamdan, Zakaria I; Sweileh, Waleed M
2018-01-01
Only a few studies have been published on the nutritional status of hemodialysis (HD) patients in Arab countries. The aim of this study was to determine the nutritional status and prevalence of malnutrition and its predictors among HD patients at An-Najah National University Hospital, Nablus, Palestine. A cross-sectional study was carried out on HD patients in this hospital. Seven-Point Subjective Global Assessment (7-point SGA) was used to assess the nutritional state of HD patients. Biochemical tests were obtained during the study period from medical files of the studied patients. A total of 106 HD patients were recruited for this study and assessed for nutritional status. More than half (60, 56.6%) of the recruited patients were males. The majority of the patients (86.8%) were above 45 years of age. Hypertension (65, 61.3%) was the most common comorbid conditions followed by diabetes mellitus (51, 48.1%). The median SGA score was 5.57 (5-6). More than half of the HD patients (56; 52.8%) were well-nourished while the remaining (50, 47.2%) had mild-to-moderate malnourishment. Univariate analysis indicated that SGA score was significantly higher in HD patients with college education (P = 0.026), nondiabetic (P = 0.044), nonhypertensive (P = 0.037), and those with current occupation (P = 0.025). No significant correlation was found between SGA score and potassium level (P = 0.134), calcium level (P = 0.883), albumin (P = 0.282), and phosphate level (P = 0.419). However, significant positive correlation was found between SGA core and hemoglobin level (P = 0.019; r = 0.227). Multivariate analysis showed no significant predictors of SGA score. In this pilot single-center study, malnutrition was detected in almost half of HD patients using SGA scale. Development of nutritional assessment protocols for HD is an important issue and needs to be followed up by health-care teams in HD centers.
Du, Qing-Yun; Wang, En-Yin; Huang, Yan; Guo, Xiao-Yi; Xiong, Yu-Jing; Yu, Yi-Ping; Yao, Gui-Dong; Shi, Sen-Lin; Sun, Ying-Pu
2016-04-01
To evaluate the independent effects of the degree of blastocoele expansion and re-expansion and the inner cell mass (ICM) and trophectoderm (TE) grades on predicting live birth after fresh and vitrified/warmed single blastocyst transfer. Retrospective study. Reproductive medical center. Women undergoing 844 fresh and 370 vitrified/warmed single blastocyst transfer cycles. None. Live-birth rate correlated with blastocyst morphology parameters by logistic regression analysis and Spearman correlations analysis. The degree of blastocoele expansion and re-expansion was the only blastocyst morphology parameter that exhibited a significant ability to predict live birth in both fresh and vitrified/warmed single blastocyst transfer cycles respectively by multivariate logistic regression and Spearman correlations analysis. Although the ICM grade was significantly related to live birth in fresh cycles according to the univariate model, its effect was not maintained in the multivariate logistic analysis. In vitrified/warmed cycles, neither ICM nor TE grade was correlated with live birth by logistic regression analysis. This study is the first to confirm that the degree of blastocoele expansion and re-expansion is a better predictor of live birth after both fresh and vitrified/warmed single blastocyst transfer cycles than ICM or TE grade. Copyright © 2016. Published by Elsevier Inc.
Lee, Jun-Young; Kim, Jeong-Hyeon; Jeon, Deok-Jin; Han, Jaehyun; Yeo, Jong-Souk
2016-10-12
A phase change nanowire holds a promise for nonvolatile memory applications, but its transition mechanism has remained unclear due to the analytical difficulties at atomic resolution. Here we obtain a deeper understanding on the phase transition of a single crystalline Ge 2 Sb 2 Te 5 nanowire (GST NW) using atomic scale imaging, diffraction, and chemical analysis. Our cross-sectional analysis has shown that the as-grown hexagonal close-packed structure of the single crystal GST NW transforms to a metastable face-centered cubic structure due to the atomic migration to the pre-existing vacancy layers in the hcp structure going through iterative electrical switching. We call this crystal structure transformation "metastabilization", which is also confirmed by the increase of set-resistance during the switching operation. For the set to reset transition between crystalline and amorphous phases, high-resolution imaging indicates that the longitudinal center of the nanowire mainly undergoes phase transition. According to the atomic scale analysis of the GST NW after repeated electrical switching, partial crystallites are distributed around the core-centered amorphous region of the nanowire where atomic migration is mainly induced, thus potentially leading to low power electrical switching. These results provide a novel understanding of phase change nanowires, and can be applied to enhance the design of nanowire phase change memory devices for improved electrical performance.
Santori, G; Fontana, I; Bertocchi, M; Gasloli, G; Valente, U
2010-05-01
Following the example of many Western countries, where a "minimum volume rule" policy has been adopted as a quality parameter for complex surgical procedures, the Italian National Transplant Centre set the minimum number of kidney transplantation procedures/y at 30/center. The number of procedures performed in a single center over a large period may be treated as a time series to evaluate trends, seasonal cycles, and nonsystematic fluctuations. Between January 1, 1983, and December 31, 2007, we performed 1376 procedures in adult or pediatric recipients from living or cadaveric donors. The greatest numbers of cases/y were performed in 1998 (n = 86) followed by 2004 (n = 82), 1996 (n = 75), and 2003 (n = 73). A time series analysis performed using R Statistical Software (Foundation for Statistical Computing, Vienna, Austria), a free software environment for statistical computing and graphics, showed a whole incremental trend after exponential smoothing as well as after seasonal decomposition. However, starting from 2005, we observed a decreased trend in the series. The number of kidney transplants expected to be performed for 2008 by using the Holt-Winters exponential smoothing applied to the period 1983 to 2007 suggested 58 procedures, while in that year there were 52. The time series approach may be helpful to establish a minimum volume/y at a single-center level. Copyright (c) 2010 Elsevier Inc. All rights reserved.
Salas-Montiel, Rafael; Berthel, Martin; Beltran-Madrigal, Josslyn; Huant, Serge; Drezet, Aurélien; Blaize, Sylvain
2017-05-19
One of the most explored single quantum emitters for the development of nanoscale fluorescence lifetime imaging is the nitrogen-vacancy (NV) color center in diamond. An NV center does not experience fluorescence bleaching or blinking at room temperature. Furthermore, its optical properties are preserved when embedded into nanodiamond hosts. This paper focuses on the modeling of the local density of states (LDOS) in a plasmonic nanofocusing structure with an NV center acting as local illumination sources. Numerical calculations of the LDOS near such a nanostructure were done with a classical electric dipole radiation placed inside a diamond sphere as well as near-field optical fluorescence lifetime imaging of the structure. We found that Purcell factors higher than ten can be reached with diamond nanospheres of radius less than 5 nm and at a distance of less than 20 nm from the surface of the structure. Although the spatial resolution of the experiment is limited by the size of the nanodiamond, our work supports the analysis and interpretation of a single NV color center in a nanodiamond as a probe for scanning near-field optical microscopy.
New design concept of monopole antenna array for UHF 7T MRI.
Hong, Suk-Min; Park, Joshua Haekyun; Woo, Myung-Kyun; Kim, Young-Bo; Cho, Zang-Hee
2014-05-01
We have developed and evaluated a monopole antenna array that can increase sensitivity at the center of the brain for 7T MRI applications. We have developed a monopole antenna array that has half the length of a conventional dipole antenna with eight channels for brain imaging with a 7T MRI. The eight-channel monopole antenna array and conventional eight-channel transceiver surface coil array were evaluated and compared in terms of transmit properties, specific absorption ratio (SAR), and sensitivity. The sensitivity maps were generated by dividing the SNR map by the flip angle distribution. A single surface coil provides asymmetric sensitivity resulting in reduced sensitivity at the center of the brain. In contrast, a single monopole antenna provides higher sensitivity at the center of the brain. Moreover, the monopole antenna array provides uniform sensitivity over the entire brain, and the sensitivity gain was 1.5 times higher at the center of the brain compared with the surface coil array. The monopole antenna array is a promising candidate for MRI applications, especially for brain imaging in a 7T MRI because it provides increased sensitivity at the center of the brain. Copyright © 2013 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Golbedaghi, Reza; Azimi, Saeid; Molaei, Atefeh; Hatami, Masoud; Notash, Behrouz
2017-10-01
A new Schiff base ligand HL, 1,3-bis(2-((Z)-(2-aminoethylimino)methyl)phenoxy)ethylene di amine, has been synthesized from the reaction of a new aldehyde and ethylenediamine. After preparation the Schiff base, a new dinuclear Cu(II) complex with two different geometry for each metal ion was synthesized. Single crystal X-ray structure analysis of the complex Cu(II) showed that the complex is binuclear and all nitrogen and oxygen atoms of ligand (N4O3) are coordinated to two Cu(II) center ions. The crystal structure studying shows, a perchlorate ion has been coordinated to the two Cu(II) metal centers as bridged and another perchlorate coordinated to the one of Cu(II) ion as terminal. However, two interesting structures square pyramidal and distorted octahedral Cu(II) ions are bridged asymmetrically by a perchlorate ion and oxygen of hydroxyl group of Schiff base ligand. In addition, we had a theoretical study to have a comparison of experimental and theoretical results we determined the HOMO and LUMO orbitals.
Quantum measurement of a rapidly rotating spin qubit in diamond.
Wood, Alexander A; Lilette, Emmanuel; Fein, Yaakov Y; Tomek, Nikolas; McGuinness, Liam P; Hollenberg, Lloyd C L; Scholten, Robert E; Martin, Andy M
2018-05-01
A controlled qubit in a rotating frame opens new opportunities to probe fundamental quantum physics, such as geometric phases in physically rotating frames, and can potentially enhance detection of magnetic fields. Realizing a single qubit that can be measured and controlled during physical rotation is experimentally challenging. We demonstrate quantum control of a single nitrogen-vacancy (NV) center within a diamond rotated at 200,000 rpm, a rotational period comparable to the NV spin coherence time T 2 . We stroboscopically image individual NV centers that execute rapid circular motion in addition to rotation and demonstrate preparation, control, and readout of the qubit quantum state with lasers and microwaves. Using spin-echo interferometry of the rotating qubit, we are able to detect modulation of the NV Zeeman shift arising from the rotating NV axis and an external DC magnetic field. Our work establishes single NV qubits in diamond as quantum sensors in the physically rotating frame and paves the way for the realization of single-qubit diamond-based rotation sensors.
Quantum measurement of a rapidly rotating spin qubit in diamond
Fein, Yaakov Y.; Hollenberg, Lloyd C. L.; Scholten, Robert E.
2018-01-01
A controlled qubit in a rotating frame opens new opportunities to probe fundamental quantum physics, such as geometric phases in physically rotating frames, and can potentially enhance detection of magnetic fields. Realizing a single qubit that can be measured and controlled during physical rotation is experimentally challenging. We demonstrate quantum control of a single nitrogen-vacancy (NV) center within a diamond rotated at 200,000 rpm, a rotational period comparable to the NV spin coherence time T2. We stroboscopically image individual NV centers that execute rapid circular motion in addition to rotation and demonstrate preparation, control, and readout of the qubit quantum state with lasers and microwaves. Using spin-echo interferometry of the rotating qubit, we are able to detect modulation of the NV Zeeman shift arising from the rotating NV axis and an external DC magnetic field. Our work establishes single NV qubits in diamond as quantum sensors in the physically rotating frame and paves the way for the realization of single-qubit diamond-based rotation sensors. PMID:29736417
Single-particle cryo-EM-Improved ab initio 3D reconstruction with SIMPLE/PRIME.
Reboul, Cyril F; Eager, Michael; Elmlund, Dominika; Elmlund, Hans
2018-01-01
Cryogenic electron microscopy (cryo-EM) and single-particle analysis now enables the determination of high-resolution structures of macromolecular assemblies that have resisted X-ray crystallography and other approaches. We developed the SIMPLE open-source image-processing suite for analysing cryo-EM images of single-particles. A core component of SIMPLE is the probabilistic PRIME algorithm for identifying clusters of images in 2D and determine relative orientations of single-particle projections in 3D. Here, we extend our previous work on PRIME and introduce new stochastic optimization algorithms that improve the robustness of the approach. Our refined method for identification of homogeneous subsets of images in accurate register substantially improves the resolution of the cluster centers and of the ab initio 3D reconstructions derived from them. We now obtain maps with a resolution better than 10 Å by exclusively processing cluster centers. Excellent parallel code performance on over-the-counter laptops and CPU workstations is demonstrated. © 2017 The Protein Society.
Dynamic fracture behavior of single and contacting Poly(methyl methacrylate) particles
DOE Office of Scientific and Technical Information (OSTI.GOV)
Parab, Niranjan D.; Guo, Zherui; Hudspeth, Matthew C.
Fracture behaviors of single, two, and multiple contacting spherical Poly (methyl methacrylate) (PMMA) particles were recorded using high speed synchrotron X-ray phase contrast imaging. A miniaturized Kolsky bar setup was used to apply dynamic compressive loading on the PMMA particles. In both single and two particle experiments, cracking initiated near the center of the particles and propagated towards the contacts. The crack bifurcated near the contact points for single particle experiments, thus forming conical fragments. The crack bifurcation and subsequent conical fragment formation was observed only at the particle-particle contact for two particle experiments. The particles were observed to fracturemore » in hemispherical fragments normal to the contact plane in the multiparticle experiments. The observed failure mechanisms strongly suggest that the maximum tensile stress near the center of the particle is the critical parameter governing fracture of the particles. Moreover, the compressive stress under the contact areas led to the bifurcation and subsequent conical fragment formation.« less
Dynamic fracture behavior of single and contacting Poly(methyl methacrylate) particles
Parab, Niranjan D.; Guo, Zherui; Hudspeth, Matthew C.; ...
2017-09-19
Fracture behaviors of single, two, and multiple contacting spherical Poly (methyl methacrylate) (PMMA) particles were recorded using high speed synchrotron X-ray phase contrast imaging. A miniaturized Kolsky bar setup was used to apply dynamic compressive loading on the PMMA particles. In both single and two particle experiments, cracking initiated near the center of the particles and propagated towards the contacts. The crack bifurcated near the contact points for single particle experiments, thus forming conical fragments. The crack bifurcation and subsequent conical fragment formation was observed only at the particle-particle contact for two particle experiments. The particles were observed to fracturemore » in hemispherical fragments normal to the contact plane in the multiparticle experiments. The observed failure mechanisms strongly suggest that the maximum tensile stress near the center of the particle is the critical parameter governing fracture of the particles. Moreover, the compressive stress under the contact areas led to the bifurcation and subsequent conical fragment formation.« less
Numerical evaluation of single central jet for turbine disk cooling
NASA Astrophysics Data System (ADS)
Subbaraman, M. R.; Hadid, A. H.; McConnaughey, P. K.
The cooling arrangement of the Space Shuttle Main Engine High Pressure Oxidizer Turbopump (HPOTP) incorporates two jet rings, each of which produces 19 high-velocity coolant jets. At some operating conditions, the frequency of excitation associated with the 19 jets coincides with the natural frequency of the turbine blades, contributing to fatigue cracking of blade shanks. In this paper, an alternate turbine disk cooling arrangement, applicable to disk faces of zero hub radius, is evaluated, which consists of a single coolant jet impinging at the center of the turbine disk. Results of the CFD analysis show that replacing the jet ring with a single central coolant jet in the HPOTP leads to an acceptable thermal environment at the disk rim. Based on the predictions of flow and temperature fields for operating conditions, the single central jet cooling system was recommended for implementation into the development program of the Technology Test Bed Engine at NASA Marshall Space Flight Center.
Ion implantation for deterministic single atom devices
NASA Astrophysics Data System (ADS)
Pacheco, J. L.; Singh, M.; Perry, D. L.; Wendt, J. R.; Ten Eyck, G.; Manginell, R. P.; Pluym, T.; Luhman, D. R.; Lilly, M. P.; Carroll, M. S.; Bielejec, E.
2017-12-01
We demonstrate a capability of deterministic doping at the single atom level using a combination of direct write focused ion beam and solid-state ion detectors. The focused ion beam system can position a single ion to within 35 nm of a targeted location and the detection system is sensitive to single low energy heavy ions. This platform can be used to deterministically fabricate single atom devices in materials where the nanostructure and ion detectors can be integrated, including donor-based qubits in Si and color centers in diamond.
Ion implantation for deterministic single atom devices
Pacheco, J. L.; Singh, M.; Perry, D. L.; ...
2017-12-04
Here, we demonstrate a capability of deterministic doping at the single atom level using a combination of direct write focused ion beam and solid-state ion detectors. The focused ion beam system can position a single ion to within 35 nm of a targeted location and the detection system is sensitive to single low energy heavy ions. This platform can be used to deterministically fabricate single atom devices in materials where the nanostructure and ion detectors can be integrated, including donor-based qubits in Si and color centers in diamond.
Perspectives. Fall-Winter 2005-06
ERIC Educational Resources Information Center
Northeast Technical Assistance Center (NETAC), Rochester Institute of Technology, 2006
2006-01-01
PEPNet's "Perspectives" is the collaborative newsletter of the four PEPNet regional centers. This newsletter combines each centers' individual strengths into a single resource that can be used on a national level. The issue focuses on the following topics: (1) IDEA and transition to life beyond high school (Sharaine J. Rawlinson); (2)…
User-Centered Authentication: LDAP, WRAP, X.509, XML (SIG LAN: Library Automation and Networks).
ERIC Educational Resources Information Center
Coble, Jim
2000-01-01
Presents an abstract for a planned panel session on technologies for user-centered authentication and authorization currently deployed in pilot or production implementations in academic computing. Presentations included: "Implementing LSAP for Single-Password Access to Campus Resources" (Layne Nordgren); "Implementing a Scalable…
ERIC Educational Resources Information Center
McShay, James C.
2017-01-01
The author discusses how Museus' (2014) Culturally Engaging Campus Environment Model (CECE) can be used to re-envision campus multicultural centers, and programs and services that traditionally employ single-axis identity interventions when striving to support student growth and success.
ERIC Educational Resources Information Center
PEPNet, 2008
2008-01-01
PEPNet's "Perspectives" is the collaborative newsletter of the four PEPNet regional centers. This newsletter combines each centers individual strengths into a single resource that can be used on a national level. This issue focuses on the following topics: (1) PEPNet FAQs on Web, in Print; (2) Some Speech-to-Text FAQs; (3) Speech-to-Text…
2012-01-01
Background Aseptic loosening is one of the greatest problems in hip replacement surgery. The rotation center of the hip is believed to influence the longevity of fixation. The aim of this study was to compare the influence of cemented and cementless cup fixation techniques on the position of the center of rotation because cemented cup fixation requires the removal of more bone for solid fixation than the cementless technique. Methods We retrospectively compared pre- and post-operative positions of the hip rotation center in 25 and 68 patients who underwent artificial hip replacements in our department in 2007 using cemented or cementless cup fixation, respectively, with digital radiographic image analysis. Results The mean horizontal and vertical distances between the rotation center and the acetabular teardrop were compared in radiographic images taken pre- and post-operatively. The mean horizontal difference was −2.63 mm (range: -11.00 mm to 10.46 mm, standard deviation 4.23 mm) for patients who underwent cementless fixation, and −2.84 mm (range: -10.87 to 5.30 mm, standard deviation 4.59 mm) for patients who underwent cemented fixation. The mean vertical difference was 0.60 mm (range: -20.15 mm to 10.00 mm, standard deviation 3.93 mm) and 0.41 mm (range: -9.26 mm to 6.54 mm, standard deviation 3.58 mm) for the cementless and cemented fixation groups, respectively. The two fixation techniques had no significant difference on the position of the hip rotation center in the 93 patients in this study. Conclusions The hip rotation center was similarly restored using either the cemented or cementless fixation techniques in this patient cohort, indicating that the fixation technique itself does not interfere with the position of the center of rotation. To completely answer this question further studies with more patients are needed. PMID:22686355
Effect of the mass center shift for force-free flexible spacecraft
NASA Technical Reports Server (NTRS)
Meirovitch, L.; Juang, J.-N.
1975-01-01
For a spinning flexible spacecraft the mass center generally shifts relative to the nominal undeformed position. It is thought that this shift of center complicates spacecraft stability analysis. It is proved, on the basis of results achieved by Meirovitch and Calico (1972), that for the general class of force-free single-spin flexible spacecraft it is possible to ignore this shift of center without affecting the stability criteria in any significant way. A new theorem on inequalities for quadratic forms is proved to demonstrate the validity of the stability analysis.
A review of 33 years (1980-2013) of data indicating a rise in ectopic pregnancy in Saudi Arabia.
Al-Turki, Haifa A
2015-01-01
To assess the trend in ectopic pregnancy (EP) at a single center in Saudi Arabia and to compare the data with those from the rest of Saudi Arabia. In a retrospective study, data were analyzed from patients admitted to King Fahd Hospital of the University, Al Khobar, Saudi Arabia, with a diagnosis of EP between January 2011 and December 2013. The prevalence of EP was calculated as a percentage of the number of live births during the study period. A 30-year review of publications on EP in Saudi Arabia was done via search engines. During the study period, there were 58 EPs among 3818 deliveries, giving an overall incidence of 1.5% at the study center; the incidence of EP in the rest of the country during this period was 0.5%. Between 2002 and 2004, the country's incidence was 0.6% as compared with 1% at the study center. The incidence of EP in Saudi Arabia has increased in the past few decades. Copyright © 2014 International Federation of Gynecology and Obstetrics. Published by Elsevier Ireland Ltd. All rights reserved.
Turbulent Mixing of Primary and Secondary Flow Streams in a Rocket-Based Combined Cycle Engine
NASA Technical Reports Server (NTRS)
Cramer, J. M.; Greene, M. U.; Pal, S.; Santoro, R. J.; Turner, Jim (Technical Monitor)
2002-01-01
This viewgraph presentation gives an overview of the turbulent mixing of primary and secondary flow streams in a rocket-based combined cycle (RBCC) engine. A significant RBCC ejector mode database has been generated, detailing single and twin thruster configurations and global and local measurements. On-going analysis and correlation efforts include Marshall Space Flight Center computational fluid dynamics modeling and turbulent shear layer analysis. Potential follow-on activities include detailed measurements of air flow static pressure and velocity profiles, investigations into other thruster spacing configurations, performing a fundamental shear layer mixing study, and demonstrating single-shot Raman measurements.
Single-crystalline cubic structured InP nanosprings
NASA Astrophysics Data System (ADS)
Shen, G. Z.; Bando, Y.; Zhi, C. Y.; Yuan, X. L.; Sekiguchi, T.; Golberg, D.
2006-06-01
Cubic structured nanosprings, InP nanosprings, have been synthesized via a simple thermochemical process using InP and ZnS as the source materials. Each InP nanospring is formed by rolling up a single InP nanobelt with the growth direction along the ⟨111⟩ orientation. The formation of these novel nanostructures is mainly attributed to the minimization of the electrostatic energy due to the polar charges on the ±(002) side surfaces of cubic InP. Cathodoluminescence properties were also studied, which reveal that the InP nanosprings have three emission bands centered at ˜736, ˜920, and ˜980nm.
Breaking HIV News to Clients: SPIKES Strategy in Post-Test Counseling Session.
Emadi-Koochak, Hamid; Yazdi, Farhad; Haji Abdolbaghi, Mahboubeh; Salehi, Mohammad Reza; Shadloo, Behrang; Rahimi-Movaghar, Afarin
2016-05-01
Breaking bad news is one of the most burdensome tasks physicians face in their everyday practice. It becomes even more challenging in the context of HIV+ patients because of stigma and discrimination. The aim of the current study is to evaluate the quality of giving HIV seroconversion news according to SPIKES protocol. Numbers of 154 consecutive HIV+ patients from Imam Khomeini Hospital testing and counseling center were enrolled in this study. Patients were inquired about how they were given the HIV news and whether or not they received pre- and post-test counseling sessions. Around 51% of them were men, 80% had high school education, and 56% were employed. Regarding marital status, 32% were single, and 52% were married at the time of the interview. Among them, 31% had received the HIV news in a counseling center, and only 29% had pre-test counseling. SPIKES criteria were significantly met when the HIV news was given in an HIV counseling and testing center (P.value<0.05). Low coverage of HIV counseling services was observed in the study. SPIKES criteria were significantly met when the HIV seroconversion news was given in a counseling center. The need to further train staff to deliver HIV news seems a priority in the field of HIV care and treatment.
Superhyperfine Structure of the EPR Spectra of Nd3+ Impurity Ions in Fluorite CaF2
NASA Astrophysics Data System (ADS)
Aminov, L. K.; Gafurov, M. R.; Kurkin, I. N.; Malkin, B. Z.; Rodionov, A. A.
2018-05-01
EPR spectra of a CaF2 single crystal that was grown from melt containing a small addition of NdF3 were studied. Signals corresponding to tetragonal centers of Nd3+ ions and cubic centers of Er3+ and Yb3+ ions were found. Superhyperfine structure (SHFS) in the spectra of the Nd3+ ions was observed for the first time in this crystal; parameters of the superhyperfine interaction of the Nd3+ ions with the nearest nine fluorine ions were determined. The dependence of the resolution of the Nd3+ EPR spectrum SHFS on the incident microwave power at the temperature of T ≈ 6 K was studied. Obtained results are discussed and compared with the literature data.
The study of optical property of sapphire irradiated with 73 MeV Ca ions
NASA Astrophysics Data System (ADS)
Yang, Yitao; Zhang, Chonghong; Song, Yin; Gou, Jie; Liu, Juan; Xian, Yongqiang
2015-12-01
Single crystals of sapphire were irradiated with 73 MeV Ca ions at room temperature to the fluences of 0.1, 0.5 and 1.0 × 1014 ions/cm2. Optical properties of these samples were characterized by ultraviolet-visible spectrometry (UV-VIS) and fluorescence spectrometer (PL). In UV-VIS spectra, it is observed the absorbance bands from oxygen single vacancy (F and F+ color centers) and vacancy pair (F2+ and F22+ color centers). The oxygen single vacancy initially increases rapidly and then does not increase in the fluence range from 0.1 to 0.5 × 1014 ions/cm2. When the fluence is higher than 0.5 × 1014 ions/cm2, oxygen single vacancy starts to increase again. Oxygen vacancy pair increases monotonically with fluence for all irradiated samples. The variation of oxygen single vacancy with fluence is probably associated with the recombination of oxygen vacancies with Al interstitials and complex defect formation (such as vacancy clusters). From PL spectra, two emission bands around 3.1 and 2.34 eV are observed. The PL intensity of the emission band around 3.1 eV decreases for all the irradiated samples. For the emission band around 2.34 eV, the PL intensity initially decreases, and then increases with fluence. Meanwhile, the peak position of the emission band around 2.34 eV gradually shifts to high energy direction with increase of fluence. The decrease of the intensity of the emission bands around 3.1 and 2.34 eV could be induced by stress from the damage layer in the irradiated samples. The shift of peak position for the emission band around 2.34 eV is induced by the appearance of emission band from Al interstitials.
Small Radioisotope Power System at NASA Glenn Research Center
NASA Technical Reports Server (NTRS)
Dugala, Gina M.; Fraeman, Martin; Frankford, David P.; Duven, Dennis; Shamkovich, Andrei; Ambrose, Hollis; Meer, David W.
2012-01-01
In April 2009, NASA Glenn Research Center (GRC) formed an integrated product team (IPT) to develop a Small Radioisotope Power System (SRPS) utilizing a single Advanced Stirling Convertor (ASC) with passive balancer for possible use by the International Lunar Network (ILN) program. The ILN program is studying the feasibility of implementing a multiple node seismometer network to investigate the internal lunar structure. A single ASC produces approximately 80 W(sub e) and could potentially supply sufficient power for that application. The IPT consists of Sunpower, Inc., to provide the single ASC with balancer, The Johns Hopkins University Applied Physics Laboratory (JHU/APL) to design an engineering model Single Convertor Controller (SCC) for an ASC with balancer, and NASA GRC to provide technical support to these tasks and to develop a simulated lunar lander test stand. A controller maintains stable operation of an ASC. It regulates the alternating current produced by the linear alternator of the convertor, provides a specified output voltage, and maintains operation at a steady piston amplitude and hot end temperature. JHU/APL also designed an ASC dynamic engine/alternator simulator to aid in the testing and troubleshooting of the SCC. This paper describes the requirements, design, and development of the SCC, including some of the key challenges and the solutions chosen to overcome those issues. In addition, it describes the plans to analyze the effectiveness of a passive balancer to minimize vibration from the ASC, characterize the effect of ASC vibration on a lunar lander, characterize the performance of the SCC, and integrate the single ASC, SCC, and lunar lander test stand to characterize performance of the overall system.
CD-ROM technology at the EROS data center
Madigan, Michael E.; Weinheimer, Mary C.
1993-01-01
The vast amount of digital spatial data often required by a single user has created a demand for media alternatives to 1/2" magnetic tape. One such medium that has been recently adopted at the U.S. Geological Survey's EROS Data Center is the compact disc (CD). CD's are a versatile, dynamic, and low-cost method for providing a variety of data on a single media device and are compatible with various computer platforms. CD drives are available for personal computers, UNIX workstations, and mainframe systems, either directly connected, or through a network. This medium furnishes a quick method of reproducing and distributing large amounts of data on a single CD. Several data sets are already available on CD's, including collections of historical Landsat multispectral scanner data and biweekly composites of Advanced Very High Resolution Radiometer data for the conterminous United States. The EROS Data Center intends to provide even more data sets on CD's. Plans include specific data sets on a customized disc to fulfill individual requests, and mass production of unique data sets for large-scale distribution. Requests for a single compact disc-read only memory (CD-ROM) containing a large volume of data either for archiving or for one-time distribution can be addressed with a CD-write once (CD-WO) unit. Mass production and large-scale distribution will require CD-ROM replication and mastering.
Correction of Single Frequency Altimeter Measurements for Ionosphere Delay
NASA Technical Reports Server (NTRS)
Schreiner, William S.; Markin, Robert E.; Born, George H.
1997-01-01
This study is a preliminary analysis of the accuracy of various ionosphere models to correct single frequency altimeter height measurements for Ionospheric path delay. In particular, research focused on adjusting empirical and parameterized ionosphere models in the parameterized real-time ionospheric specification model (PRISM) 1.2 using total electron content (TEC) data from the global positioning system (GPS). The types of GPS data used to adjust PRISM included GPS line-of-sight (LOS) TEC data mapped to the vertical, and a grid of GPS derived TEC data in a sun-fixed longitude frame. The adjusted PRISM TEC values, as well as predictions by IRI-90, a climatotogical model, were compared to TOPEX/Poseidon (T/P) TEC measurements from the dual-frequency altimeter for a number of T/P tracks. When adjusted with GPS LOS data, the PRISM empirical model predicted TEC over 24 1 h data sets for a given local time to with in a global error of 8.60 TECU rms during a midnight centered ionosphere and 9.74 TECU rms during a noon centered ionosphere. Using GPS derived sun-fixed TEC data, the PRISM parameterized model predicted TEC within an error of 8.47 TECU rms centered at midnight and 12.83 TECU rms centered at noon. From these best results, it is clear that the proposed requirement of 3-4 TECU global rms for TOPEX/Poseidon Follow-On will be very difficult to meet, even with a substantial increase in the number of GPS ground stations, with any realizable combination of the aforementioned models or data assimilation schemes.
Baracat, Patrícia Junqueira Ferraz; de Sá Ferreira, Arthur
2013-12-01
The present study investigated the association between postural tasks and center of pressure spatial patterns of three-dimensional statokinesigrams. Young (n=35; 27.0±7.7years) and elderly (n=38; 67.3±8.7years) healthy volunteers maintained an undisturbed standing position during postural tasks characterized by combined sensory (vision/no vision) and biomechanical challenges (feet apart/together). A method for the analysis of three-dimensional statokinesigrams based on nonparametric statistics and image-processing analysis was employed. Four patterns of spatial distribution were derived from ankle and hip strategies according to the quantity (single; double; multi) and location (anteroposterior; mediolateral) of high-density regions on three-dimensional statokinesigrams. Significant associations between postural task and spatial pattern were observed (young: gamma=0.548, p<.001; elderly: gamma=0.582, p<.001). Robustness analysis revealed small changes related to parameter choices for histogram processing. MANOVA revealed multivariate main effects for postural task [Wilks' Lambda=0.245, p<.001] and age [Wilks' Lambda=0.308, p<.001], with interaction [Wilks' Lambda=0.732, p<.001]. The quantity of high-density regions was positively correlated to stabilogram and statokinesigram variables (p<.05 or lower). In conclusion, postural tasks are associated with center of pressure spatial patterns and are similar in young and elderly healthy volunteers. Single-centered patterns reflected more stable postural conditions and were more frequent with complete visual input and a wide base of support. Copyright © 2013 Elsevier B.V. All rights reserved.
Iyadomi, Minako; Taniguchi, Hiroaki; Higaki, Yasuki; Tanaka, Hiroaki; Horita, Mikako; Tanaka, Keitaro
2018-01-01
The purpose of the current study was to examine the influence of single-nucleotide polymorphisms (SNPs) in the peroxisome proliferator-activated receptor-δ (PPAR-δ), PPAR-γ, and α2 isoforms of the catalytic subunit of AMP-activated protein kinase (PRKAA2) on the extent of changes in anthropometric indices and blood measurements through exercise-centered lifestyle intervention in middle-aged men. A total of 109 Japanese middle-aged male subjects (47.0 ± 0.4 years) participated in the baseline health checkup, 6-month exercise-centered lifestyle intervention, and second checkup conducted several months after the subject completed the intervention. The body mass index (BMI), waist circumference, and clinical measurements, including hemoglobin Alc (HbA1c), triglyceride (TG), alanine aminotransferase (ALT), and γ-glutamyl-transpeptidase (γ-GTP), were measured at the baseline and second checkup. The three SNPs of PPAR-δ A/G (rs2267668), PPAR-γ C/G (rs1801282), and PRKAA2 A/G (rs1418442) were determined. Blunted responses in the reduction in the BMI and waist circumference were observed in A/A carriers of PPAR-δ SNP compared with G allele carriers (all p < 0.05). The A/A carriers also displayed less-marked improvements in HbA1c, TG, ALT, and γ-GTP (all p < 0.05). The current results suggest that A/A carriers of PPAR-δ SNP (rs2267668) may enjoy fewer beneficial effects of exercise-centered lifestyle intervention on anthropometric indices and blood measurements. PMID:29494521
Real-time Data Center Energy Efficiency At Pacific Northwest National Laboratory
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sisk, Daniel R.; Khaleel, Mohammad A.; Marquez, Andres
2009-05-26
The escalating consumption of power in data centers worldwide has brought the issue of data center energy efficiency to the forefront. Data center owners and operators now regard detailed knowledge of the energy efficiencies of their data centers as a competitive advantage. With funding from the Department of Energy (NNSA), PNNL has undertaken an in-depth analysis of the real-time energy efficiency for its Energy Smart Data Center Test Bed(ESDC-TB), which is housed in the mixed-use EMSL. The analysis is centered around the real-time display of The Green Grid’s proposed DCiE metric. To calculate this metric, PNNL relies on a varietymore » of sources of data. At the ESDC-TB level, the data center is instrumented to the 100% level (all power consumption, and water temperatures and flow rates are measured). Most of this data is monitored in real-time, but the exception to this is with the CRAHs, which rely on a one-time power consumption measurement for the blowers (these are single speed blowers, so a one-time measurement suffices.). Outside of the data center (EMSL facility level), PNNL relies on the following: • Real-time data from the entire chiller plant (five chillers), six chilled water pumps, and one of four cooling towers (blowers only). • One-time power measurements for a single fixed speed pump that is representative of each grouping of pumps (the other pumps are assumed to possess the same power consumption levels). • One-time power measurements for a single two-speed cooling tower blower. This same blower model is deployed in three of the four cooling towers, so is assumed to be representative for all these blowers. • One-time power measurements for a single fixed speed cooling tower pump. This same pump model is deployed in all four cooling towers, so is assumed to be representative for all these pumps. A software tool named FRED was developed by PNNL to acquire, reduce, display, and archive all the data acquired from the ESDC-TB and EMSL. FRED provides the ability to display various levels of real-time data starting at the ESDC-TB and EMSL levels, then to lower levels as desired. For example, for the ESDC-TB, graphical screens are provided at the data center level, the rack level, the server level, and even the component level. In the near-term, FRED will also display the real-time DCiE. One of the major challenges to doing this in a mixed-use facility has been to quantify the power consumption of each major mechanical or electrical subsystem that is attributable to the IT equipment housed within the ESDC-TB (i.e., NW-ICE). PNNL has tackled this issue for its five chiller plant, and the analysis is presented in the paper. The analysis for all the remaining mechanical and electrical subsystems is now underway and will be presented in future publications.« less
White OLED with a single-component europium complex.
Law, Ga-Lai; Wong, Ka-Leung; Tam, Hoi-Lam; Cheah, Kok-Wai; Wong, Wing-Tak
2009-11-16
A new direction for white organic light-emitting devices is shown, fabricated from a novel europium complex; this single component contains a double emission center of bluish-green and red, combined to a give a pure white emission (CIE x = 0.34 and y = 0.35).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pacheco, J. L.; Singh, M.; Perry, D. L.
Here, we demonstrate a capability of deterministic doping at the single atom level using a combination of direct write focused ion beam and solid-state ion detectors. The focused ion beam system can position a single ion to within 35 nm of a targeted location and the detection system is sensitive to single low energy heavy ions. This platform can be used to deterministically fabricate single atom devices in materials where the nanostructure and ion detectors can be integrated, including donor-based qubits in Si and color centers in diamond.
Compressive Testing of Stitched Frame and Stringer Alternate Configurations
NASA Technical Reports Server (NTRS)
Leone, Frank A., Jr.; Jegley, Dawn C.
2016-01-01
A series of single-frame and single-stringer compression tests were conducted at NASA Langley Research Center on specimens harvested from a large panel built using the Pultruded Rod Stitched Efficient Unitized Structure (PRSEUS) concept. Different frame and stringer designs were used in fabrication of the PRSEUS panel. In this report, the details of the experimental testing of single-frame and single-stringer compression specimens are presented, as well as discussions on the performance of the various structural configurations included in the panel.
Fabrication and Testing of High-Speed-Single-Rotor and Compound-Rotor Systems
2016-05-04
pitch link loads, hub loads, rotor wakes and performance of high -speed single-rotor and compound-rotor systems to support 1. REPORT DATE (DD-MM-YYYY) 4...Public Release; Distribution Unlimited UU UU UU UU 05-04-2016 14-Jul-2014 13-Jan-2016 Final Report: Fabrication and Testing of High -Speed Single- Rotor and...Final Report: Fabrication and Testing of High -Speed Single-Rotor and Compound-Rotor Systems Report Title The Alfred Gessow Rotorcraft Center has
Fabrication and Testing of High-Speed Single-Rotor and Compound-Rotor Systems
2016-04-05
pitch link loads, hub loads, rotor wakes and performance of high -speed single-rotor and compound-rotor systems to support 1. REPORT DATE (DD-MM-YYYY) 4...Public Release; Distribution Unlimited UU UU UU UU 05-04-2016 14-Jul-2014 13-Jan-2016 Final Report: Fabrication and Testing of High -Speed Single- Rotor and...Final Report: Fabrication and Testing of High -Speed Single-Rotor and Compound-Rotor Systems Report Title The Alfred Gessow Rotorcraft Center has
Kotze, Paulo Gustavo; Abou-Rejaile, Vinícius Rezende; Uiema, Luciana Aparecida; Olandoski, Marcia; Sartor, Maria Cristina; Miranda, Eron Fábio; Kotze, Lorete Maria da Silva; Saad-Hossne, Rogério
2014-01-01
Adalimumab is a fully-human antibody that inhibits TNF alpha, with a significant efficacy for long-term maintenance of remission. Studies with this agent in Latin American Crohn's disease patients are scarce. The objective of this study was to outline clinical remission rates after 12 months of adalimumab therapy for Crohn's disease patients. Retrospective, single-center, observational study of a Brazilian case series of Crohn's disease patients under adalimumab therapy. Variables analyzed: demographic data, Montreal classification, concomitant medication, remission rates after 1, 4, 6 and 12 months. Remission was defined as Harvey-Bradshaw Index ≤ 4, and non-responder-imputation and last-observation-carried-forward analysis were used. The influence of infliximab on remission rates was analyzed by Fischer and Chi-square tests (P<0.05). Fifty patients, with median age of 35 years at therapy initiation, were included. Remission rates after 12 months of therapy were 54% under non-responder-imputation and 88% under last-observation-carried-forward analysis. After 12 months, remission on patients with previous infliximab occurred in 69.23% as compared to 94.59% in infliximab-naïve patients (P = 0.033). Adalimumab was effective in maintaining clinical remission after 12 months of therapy, with an adequate safety profile, and was also more effective in infliximab naïve patients.
Daumit, G L; Dalcin, A T; Jerome, G J; Young, D R; Charleston, J; Crum, R M; Anthony, C; Hayes, J H; McCarron, P B; Khaykin, E; Appel, L J
2011-08-01
Overweight and obesity are epidemic in populations with serious mental illnesses. We developed and pilot-tested a behavioral weight-loss intervention appropriately tailored for persons with serious mental disorders. We conducted a single-arm pilot study in two psychiatric rehabilitation day programs in Maryland, and enrolled 63 overweight or obese adults. The 6-month intervention provided group and individual weight management and group physical activity classes. The primary outcome was weight change from baseline to 6 months. A total of 64% of those potentially eligible enrolled at the centers. The mean age was 43.7 years; 56% were women; 49% were white; and over half had schizophrenia or a schizoaffective disorder. One-third had hypertension and one-fifth had diabetes. In total, 52 (82%) completed the study; others were discharged from psychiatric centers before completion of the study. Average attendance across all weight management sessions was 70% (87% on days participants attended the center) and 59% for physical activity classes (74% on days participants attended the center). From a baseline mean of 210.9 lbs (s.d. 43.9), average weight loss for 52 participants was 4.5 lb (s.d. 12.8) (P<0.014). On average, participants lost 1.9% of body weight. Mean waist circumference change was 3.1 cm (s.d. 5.6). Participants on average increased the distance on the 6-minute walk test by 8%. This pilot study documents the feasibility and preliminary efficacy of a behavioral weight-loss intervention in adults with serious mental illness who were attendees at psychiatric rehabilitation centers. The results may have implications for developing weight-loss interventions in other institutional settings such as schools or nursing homes.
Center for Advanced Propulsion Systems
1993-02-01
breakup model for two chamber pressures. 7.5.4 Exciplex images for a single main injection. Images are 126 ensemble averaged for 8 individual images. Times...to obtain data using an electronic fuel injector (UCORS). Exciplex fluorescence and photographic imaging were used to study liquid and vapor...later paper, (Bower and Foster, 1993) in the same combustion bomb, the authors applied Exciplex fluorescence techniques to visualize fuel liquid and fuel
Monoquaternary neuromuscular blocking agents based on 1-tetralone and 1-indanone.
Biggs, D F; Casy, A F; Chu, I; Coutts, R T
1976-04-01
The preparation of three isomeric 1-tetralone hydrozones 4 and three isomeric 1-indanone hydrozones 5 possessing a single quaternary ammonium center is described. Several of the compounds possessed significant neuromuscular blocking activity, and two approached suxamethonium in potency. 1H NMR evidence obtained from a study of the N,N-dimethylhydrozones indicated that the hydrazones adopted an E configuration in solution.
Savasi, Valeria; Oneta, Monica; Parrilla, Bina; Cetin, Irene
2013-04-01
The debate on HCV discordant couples requiring assisted reproduction is still open today, and specific guidelines have not yet been established on whether or not physicians should treat HCV discordant couples who require ART. We studied the results of our reproductive assistance with sperm washing in HCV discordant couples, all treated in a single center, including the serological status of mothers and babies, and the outcome of the pregnancies. Prospective study conducted between January 2008 and December 2010 in our Reproductive Center in Sacco Hospital, University of Milan. Thirty-five HCV serodiscordant infertile couples with an HCV viremic positive male partner were enrolled. All of them completed the immuno-virological and fertility triage, and were treated according to our clinical protocols. Forty-seven superovulation and IUI and 38 second-level ART procedures are reported. The pregnancy rates for IUI and ICSI are similar to those reported by the Italian ART register. All the 85 sperm samples were treated with sperm washing technique to reduce HCV in semen and the possible risk of transmission. We did not observe any preterm delivery or negative perinatal outcome. No mothers or babies are infected by HCV. This is the biggest prospective study conducted in a single center involving HCV discordant infertile couples in an ART program. Although sexual transmission of HCV is very low, in subfertile or infertile couples sperm washing should be used to treat HCV positive semen before ART. We suggest that it is not necessary to perform nested PCR to detect HCV RNA in the final swim-up. Since the presence of HCV in semen implies a possible risk of nosocomial contamination, safety regulations must be strictly applied in assisted reproduction laboratories. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Infection Rate after Cranial Neurosurgical Procedures: A Prospective Single-Center Study.
Strahm, Carol; Albrich, Werner C; Zdravkovic, Vilijam; Schöbi, Barbara; Hildebrandt, Gerhard; Schlegel, Matthias
2018-03-01
To determine infection rate (IR) and to identify modifiable risk factors (RF) in cranial neurosurgery in a neurosurgical department for tertiary referral as part of an infection control surveillance to reduce surgical site infections (SSI). A prospective SSI incidence cohort study from February 2013 to January 2014 was performed in a tertiary-care neurosurgical teaching hospital and referral center. All consecutive adults undergoing any cranial neurosurgical procedure were included. Data were collected by a trained member of the infection control staff during the twice-weekly visits of the hospitalized patients. Follow-up was 30 days (procedures without implant) and 1 year (procedures involving permanent implants). SSI was diagnosed according to criteria of CDC. A total of 317 patients undergoing 333 index procedures were included. The median age was 61 years (range, 17-91 years) and 46% were female. Survival in patients with completed follow-up was 76% (196/258). Overall, IR was 7.2% (24/333 index procedures); in 96% (23/24), a neurosurgical implant was involved. The IR of extraventricular drainage (EVD) was 12.5% (13.1/1000 EVD days). The main causative pathogens were Staphylococcus aureus followed by coagulase-negative staphylococci and Propionibacterium acnes. Independent RF for neurosurgical SSI were EVD as part of the index operation and body mass index >25 kg/m 2 . IR was in accordance with recent prospective single-center studies (reported IR between 1.6% and 9%). EVD placement was identified as the strongest modifiable RF for SSI in cranial neurosurgical procedures. The need for standard infection control procedures for the insertion and maintenance of EVDs to avoid their contamination is reinforced. Copyright © 2017 Elsevier Inc. All rights reserved.
Reducing preterm birth by a statewide multifaceted program: an implementation study.
Newnham, John P; White, Scott W; Meharry, Suzanne; Lee, Han-Shin; Pedretti, Michelle K; Arrese, Catherine A; Keelan, Jeffrey A; Kemp, Matthew W; Dickinson, Jan E; Doherty, Dorota A
2017-05-01
A comprehensive preterm birth prevention program was introduced in the state of Western Australia encompassing new clinical guidelines, an outreach program for health care practitioners, a public health program for women and their families based on print and social media, and a new clinic at the state's sole tertiary level perinatal center for referral of those pregnant women at highest risk. The initiative had the single aim of safely lowering the rate of preterm birth. The objective of the study was to evaluate the outcomes of the initiative on the rates of preterm birth both statewide and in the single tertiary level perinatal referral center. This was a prospective population-based cohort study of perinatal outcomes before and after 1 full year of implementation of the preterm birth prevention program. In the state overall, the rate of singleton preterm birth was reduced by 7.6% and was lower than in any of the preceding 6 years. This reduction amounted to 196 cases relative to the year before the introduction of the initiative and the effect extended from the 28-31 week gestational age group onward. Within the tertiary level center, the rate of preterm birth in 2015 was also significantly lower than in the preceding years. A comprehensive and multifaceted preterm birth prevention program aimed at both health care practitioners and the general public, operating within the environment of a government-funded universal health care system can significantly lower the rate of early birth. Further research is now required to increase the effect and to determine the relative contributions of each of the interventions. Copyright © 2016 The Author(s). Published by Elsevier Inc. All rights reserved.
Ang, Marcus; Tan, Donald; Mehta, Jodhbir S
2012-05-31
Small incision lenticule extraction or SMILE is a novel form of 'flapless' corneal refractive surgery that was adapted from refractive lenticule extraction (ReLEx). SMILE uses only one femtosecond laser to complete the refractive surgery, potentially reducing surgical time, side effects, and cost. If successful, SMILE could potentially replace the current, widely practiced laser in-situ keratomileusis or LASIK. The aim of this study is to evaluate whether SMILE is non-inferior to LASIK in terms of refractive outcomes at 3 months post-operatively. Single tertiary center, parallel group, single-masked, paired-eye design, non-inferiority, randomized controlled trial. Participants who are eligible for LASIK will be enrolled for study after informed consent. Each participant will be randomized to receive SMILE and LASIK in each eye. Our primary hypothesis (stated as null) in this non-inferiority trial would be that SMILE differs from LASIK in adults (>21 years old) with myopia (> -3.00 diopter (D)) at a tertiary eye center in terms of refractive predictability at 3 months post-operatively. Our secondary hypothesis (stated as null) in this non-inferiority trial would be that SMILE differs from LASIK in adults (>21 years old) with myopia (> -3.00 D) at a tertiary eye center in terms of other refractive outcomes (efficacy, safety, higher-order aberrations) at 3 months post-operatively. Our primary outcome is refractive predictability, which is one of several standard refractive outcomes, defined as the proportion of eyes achieving a postoperative spherical equivalent (SE) within ±0.50 D of the intended target. Randomization will be performed using random allocation sequence generated by a computer with no blocks or restrictions, and implemented by concealing the number-coded surgery within sealed envelopes until just before the procedure. In this single-masked trial, subjects and their caregivers will be masked to the assigned treatment in each eye. This novel trial will provide information on whether SMILE has comparable, if not superior, refractive outcomes compared to the established LASIK for myopia, thus providing evidence for translation into clinical practice. Clinicaltrials.gov NCT01216475.
Lentz, Robert J; Argento, A Christine; Colby, Thomas V; Rickman, Otis B; Maldonado, Fabien
2017-07-01
Transbronchial lung biopsy with a cryoprobe, or cryobiopsy, is a promising new bronchoscopic biopsy technique capable of obtaining larger and better-preserved samples than previously possible using traditional biopsy forceps. Over two dozen case series and several small randomized trials are now available describing experiences with this technique, largely for the diagnosis of diffuse parenchymal lung disease (DPLD), in which the reported diagnostic yield is typically 70% to 80%. Cryobiopsy technique varies widely between centers and this predominantly single center-based retrospective literature heterogeneously defines diagnostic yield and complications, limiting the degree to which this technique can be compared between centers or to surgical lung biopsy (SLB). This review explores the broad range of cryobiopsy techniques currently in use, their rationale, the current state of the literature, and suggestions for the direction of future study into this promising but unproven procedure.
High-entropy alloys in hexagonal close-packed structure
Gao, Michael C.; Zhang, B.; Guo, S. M.; ...
2015-08-28
The microstructures and properties of high-entropy alloys (HEAs) based on the face-centered cubic and body-centered cubic structures have been studied extensively in the literature, but reports on HEAs in the hexagonal close-packed (HCP) structure are very limited. Using an efficient strategy in combining phase diagram inspection, CALPHAD modeling, and ab initio molecular dynamics simulations, a variety of new compositions are suggested that may hold great potentials in forming single-phase HCP HEAs that comprise rare earth elements and transition metals, respectively. Lastly, experimental verification was carried out on CoFeReRu and CoReRuV using X-ray diffraction, scanning electron microscopy, and energy dispersion spectroscopy.
Multiple-photon excitation of nitrogen vacancy centers in diamond
NASA Astrophysics Data System (ADS)
Ji, Peng; Balili, R.; Beaumariage, J.; Mukherjee, S.; Snoke, D.; Dutt, M. V. Gurudev
2018-04-01
We report the observation of multiphoton photoluminescence excitation (PLE) below the resonant energies of nitrogen vacancy (NV) centers in diamond. The quadratic and cubic dependence of the integrated fluorescence intensity as a function of excitation power indicates a two-photon excitation pathway for the NV- charge state and a three-photon process involved for the neutral NV0 charge state, respectively. Comparing the total multiphoton energy with its single-photon equivalent, the PLE spectra follows the absorption spectrum of single photon excitation. We also observed that the efficiency of photoluminescence for different charge states, as well as the decay time constant, was dependent on the excitation wavelength and power.
Strain Coupling of a Nitrogen-Vacancy Center Spin to a Diamond Mechanical Oscillator
NASA Astrophysics Data System (ADS)
Teissier, J.; Barfuss, A.; Appel, P.; Neu, E.; Maletinsky, P.
2014-07-01
We report on single electronic spins coupled to the motion of mechanical resonators by a novel mechanism based on crystal strain. Our device consists of single-crystal diamond cantilevers with embedded nitrogen-vacancy center spins. Using optically detected electron spin resonance, we determine the unknown spin-strain coupling constants and demonstrate that our system resides well within the resolved sideband regime. We realize coupling strengths exceeding 10 MHz under mechanical driving and show that our system has the potential to reach strong coupling. Our novel hybrid system forms a resource for future experiments on spin-based cantilever cooling and coherent spin-oscillator coupling.
High power Yb:CALGO ultrafast regenerative amplifier for industrial application
NASA Astrophysics Data System (ADS)
Caracciolo, E.; Guandalini, A.; Pirzio, F.; Kemnitzer, M.; Kienle, F.; Agnesi, A.; Aus der Au, J.
2017-02-01
We present a high-power, single-crystal based, Yb:CALGO regenerative amplifier. The system delivers more than 50 W output power in continuous-wave regime, with diffraction limited beam quality. In Q-switching regime the spectrum is centered at 1043 nm and is 11 nm wide. In regenerative amplification experiments we achieved 34 W at 500 kHz with 12.7 nm FWHM wide spectra centered at 1044 nm seeding with a broadly tunable, single-prism SESAM mode-locked Yb:CALGO laser providing 9 nm wide spectra at 1049 nm. Pulse duration after compression was 140 fs, with excellent beam quality (M2 < 1.25).
NASA Astrophysics Data System (ADS)
Jiang, Feng-Jian; Ye, Jian-Feng; Jiao, Zheng; Jiang, Jun; Ma, Kun; Yan, Xin-Hu; Lv, Hai-Jiang
2018-05-01
We perform a proof-of-principle experiment that uses a single negatively charged nitrogen–vacancy (NV) color center with a nearest neighbor 13C nuclear spin in diamond to detect the strength and direction (including both polar and azimuth angles) of a static vector magnetic field by optical detection magnetic resonance (ODMR) technique. With the known hyperfine coupling tensor between an NV center and a nearest neighbor 13C nuclear spin, we show that the information of static vector magnetic field could be extracted by observing the pulsed continuous wave (CW) spectrum. Project supported by the National Natural Science Foundation of China (Grant Nos. 11305074, 11135002, and 11275083), the Key Program of the Education Department Outstanding Youth Foundation of Anhui Province, China (Grant No. gxyqZD2017080), and the Education Department Natural Science Foundation of Anhui Province, China (Grant No. KJHS2015B09).
Yeom, Jeong Seon; Jung, Bang Chul; Jin, Hu
2018-01-01
In this paper, we propose a novel low-complexity multi-user superposition transmission (MUST) technique for 5G downlink networks, which allows multiple cell-edge users to be multiplexed with a single cell-center user. We call the proposed technique diversity-controlled MUST technique since the cell-center user enjoys the frequency diversity effect via signal repetition over multiple orthogonal frequency division multiplexing (OFDM) sub-carriers. We assume that a base station is equipped with a single antenna but users are equipped with multiple antennas. In addition, we assume that the quadrature phase shift keying (QPSK) modulation is used for users. We mathematically analyze the bit error rate (BER) of both cell-edge users and cell-center users, which is the first theoretical result in the literature to the best of our knowledge. The mathematical analysis is validated through extensive link-level simulations. PMID:29439413
Yeom, Jeong Seon; Chu, Eunmi; Jung, Bang Chul; Jin, Hu
2018-02-10
In this paper, we propose a novel low-complexity multi-user superposition transmission (MUST) technique for 5G downlink networks, which allows multiple cell-edge users to be multiplexed with a single cell-center user. We call the proposed technique diversity-controlled MUST technique since the cell-center user enjoys the frequency diversity effect via signal repetition over multiple orthogonal frequency division multiplexing (OFDM) sub-carriers. We assume that a base station is equipped with a single antenna but users are equipped with multiple antennas. In addition, we assume that the quadrature phase shift keying (QPSK) modulation is used for users. We mathematically analyze the bit error rate (BER) of both cell-edge users and cell-center users, which is the first theoretical result in the literature to the best of our knowledge. The mathematical analysis is validated through extensive link-level simulations.
Single transverse mode laser in a center-sunken and cladding-trenched Yb-doped fiber.
Liu, Yehui; Zhang, Fangfang; Zhao, Nan; Lin, Xianfeng; Liao, Lei; Wang, Yibo; Peng, Jinggang; Li, Haiqing; Yang, LuYun; Dai, NengLi; Li, Jinyan
2018-02-05
We report a novel center-sunken and cladding-trenched Yb-doped fiber, which was fabricated by a modified chemical vapor deposition process with a solution-doping technique. The simulation results showed that the fiber with a core diameter of 40 µm and a numerical aperture of 0.043 has a 1217 µm 2 effective mode area at 1080 nm. It is also disclosed that the leakage loss can be reduced lower than 0.01 dB/m for the LP 01 mode, while over 80 dB/m for the LP 11 mode by optimizing the bending radius as 14 cm. A 456 W laser output was observed in a MOPA structure. The laser slope efficiency was measured to be 79% and the M 2 was less than 1.1, which confirmed the single mode operation of the large mode area center-sunken cladding-trenched Yb-doped fiber.
Small field output factors evaluation with a microDiamond detector over 30 Italian centers.
Russo, Serenella; Reggiori, Giacomo; Cagni, Elisabetta; Clemente, Stefania; Esposito, Marco; Falco, Maria Daniela; Fiandra, Christian; Giglioli, Francesca Romana; Marinelli, Marco; Marino, Carmelo; Masi, Laura; Pimpinella, Maria; Stasi, Michele; Strigari, Lidia; Talamonti, Cinzia; Villaggi, Elena; Mancosu, Pietro
2016-12-01
The aim of the study was a multicenter evaluation of MLC&jaws-defined small field output factors (OF) for different linear accelerator manufacturers and for different beam energies using the latest synthetic single crystal diamond detector commercially available. The feasibility of providing an experimental OF data set, useful for on-site measurements validation, was also evaluated. This work was performed in the framework of the Italian Association of Medical Physics (AIFM) SBRT working group. The project was subdivided in two phases: in the first phase each center measured OFs using their own routine detector for nominal field sizes ranging from 10×10cm 2 to 0.6×0.6cm 2 . In the second phase, the measurements were repeated in all centers using the PTW 60019 microDiamond detector. The project enrolled 30 Italian centers. Micro-ion chambers and silicon diodes were used for OF measurements in 24 and 6 centers respectively. Gafchromic films and TLDs were used for very small field OFs in 3 and 1 centers. Regarding the measurements performed with the user's detectors, OF standard deviations (SD) for field sizes down to 2×2cm 2 were in all cases <2.7%. In the second phase, a reduction of around 50% of the SD was obtained using the microDiamond detector. The measured values presented in this multicenter study provide a consistent dataset for OFs that could be a useful tool for improving dosimetric procedures in centers. The microDiamond data present a small variation among the centers confirming that this detector can contribute to improve overall accuracy in radiotherapy. Copyright © 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
Krauss, J K; Halve, B
2004-04-01
There is no agreement on the best diagnostic criteria for selecting patients with normal pressure hydrocephalus (NPH) for CSF shunting. The primary objective of the present study was to provide a contemporary survey on diagnostic algorithms and therapeutic decision-making in clinical practice. The secondary objective was to estimate the incidence of NPH. Standardized questionnaires with sections on the incidence of NPH and the frequency of shunting, evaluation of clinical symptoms, and signs, diagnostic studies, therapeutic decision-making and operative techniques, postoperative outcome and complications, and the profiles of different centers, were sent to 82 neurosurgical centers in Germany known to participate in the care of patients with NPH. Data were analyzed from 49 of 53 centers which responded to the survey (65%). The estimated annual incidence of NPH was 1.8 cases/100.000 inhabitants. Gait disturbance was defined as the most important sign of NPH (61%). There was a wide variety in the choice of diagnostic tests. Cisternography was performed routinely only in single centers. Diagnostic CSF removal was used with varying frequency by all centers except one, but the amount of CSF removed by lumbar puncture differed markedly between centers. There was poor agreement on criteria for evaluation of continuous intracranial pressure recordings regarding both the amplitude and the relative frequency of B-waves. Both periventricular and deep white matter lesions were present in about 50% of patients being shunted, indicating that vascular comorbidity in NPH patients has gained more acceptance. Programmable shunts were used by more than half of the centers, and newer valve types such as gravitational valves have become more popular. According to the present survey, new diagnostic and therapeutic concepts on NPH have penetrated daily routine to a certain extent. Wide variability, however, still exists among different neurosurgical centers.
DOT National Transportation Integrated Search
2012-09-01
The Center for Health and Safety Culture conducted research for the Idaho Transportation Department to develop media messages and tools to reduce fatalities and serious injuries related to Run-Off-the-Road, single-vehicle crashes in Idaho using the P...
Development of the Prosodic Features of Infants' Vocalizing.
ERIC Educational Resources Information Center
Lane, Harlan; Sheppard, William
Traditional research methods of recording infant verbal behavior, namely, descriptions by a single observer transcribing the utterances of a single infant in a naturalistic setting, have been inadequate to provide data necessary for modern linguistic analyses. The Center for Research on Language and Language Behavior has undertaken to correct this…
DOT National Transportation Integrated Search
2000-03-01
On November 16, 1999, at the Transportation Technology Center in Pueblo, Colorado, a test was conducted of a single rail passenger car colliding with a fixed wall at 35 mph. The car was instrumented to measure (1) the deformations of critical structu...
Presentation Software and the Single Computer.
ERIC Educational Resources Information Center
Brown, Cindy A.
1998-01-01
Shows how the "Kid Pix" software and a single multimedia computer can aid classroom instruction for kindergarten through second grade. Topics include using the computer as a learning center for small groups of students; making a "Kid Pix" slide show; using it as an electronic chalkboard; and creating curriculum-related…
Federal Register 2010, 2011, 2012, 2013, 2014
2012-07-13
... INFORMATION CONTACT: Astrid Lopez-Goldberg, Center for Drug Evaluation and Research, Food and Drug... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2012-N-0563] Single-Ingredient, Immediate-Release Drug Products Containing Oxycodone for Oral Administration and...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Madden, Jeremy T.; Toth, Scott J.; Dettmar, Christopher M.
Nonlinear optical (NLO) instrumentation has been integrated with synchrotron X-ray diffraction (XRD) for combined single-platform analysis, initially targeting applications for automated crystal centering. Second-harmonic-generation microscopy and two-photon-excited ultraviolet fluorescence microscopy were evaluated for crystal detection and assessed by X-ray raster scanning. Two optical designs were constructed and characterized; one positioned downstream of the sample and one integrated into the upstream optical path of the diffractometer. Both instruments enabled protein crystal identification with integration times between 80 and 150 µs per pixel, representing a ~10 3–10 4-fold reduction in the per-pixel exposure time relative to X-ray raster scanning. Quantitative centering andmore » analysis of phenylalanine hydroxylase fromChromobacterium violaceumcPAH,Trichinella spiralisdeubiquitinating enzyme TsUCH37, human κ-opioid receptor complex kOR-T4L produced in lipidic cubic phase (LCP), intimin prepared in LCP, and α-cellulose samples were performed by collecting multiple NLO images. The crystalline samples were characterized by single-crystal diffraction patterns, while α-cellulose was characterized by fiber diffraction. Good agreement was observed between the sample positions identified by NLO and XRD raster measurements for all samples studied.« less
NASA Technical Reports Server (NTRS)
Wing, David J.; Leavitt, Laurence D.; Re, Richard J.
1993-01-01
An investigation was conducted at wind-off conditions in the static-test facility of the Langley 16-Foot Transonic Tunnel to determine the internal performance characteristics of a single expansion-ramp nozzle with thrust-vectoring capability to 105 degrees. Thrust vectoring was accomplished by the downward rotation of an upper flap with adaptive capability for internal contouring and a corresponding rotation of a center-pivoted lower flap. The static internal performance of configurations with pitch thrust-vector angles of 0 degrees, 60 degrees, and 105 degrees each with two throat areas, was investigated. The nozzle pressure ratio was varied from 1.5 to approximately 8.0 (5.0 for the maximum throat area configurations). Results of this study indicated that the nozzle configuration of the present investigation, when vectored, provided excellent flow-turning capability with relatively high levels of internal performance. In all cases, the thrust vector angle was a function of the nozzle pressure ratio. This result is expected because the flow is bounded by a single expansion surface on both vectored- and unvectored-nozzle geometries.
Variability in Antithrombotic Therapy Regimens Peri-TAVR: A Single Academic Center Experience.
Rossi, Jeffrey E; Noll, Andrew; Bergmark, Brian; McCabe, James M; Nemer, David; Okada, David R; Vasudevan, Anant; Davidson, Michael; Welt, Frederick; Eisenhauer, Andrew; Shah, Pinak; Giugliano, Robert
2015-12-01
The aim of this study was to describe peri-procedural antithrombotic use in patients undergoing transcatheter aortic valve replacement (TAVR) at a single academic medical center. Retrospective collection of antiplatelet and anticoagulant use during the index hospitalization for all patients undergoing TAVR at our institution from April 2009 through March 2014. Of a total of 255 patients undergoing the procedure, 132 (51%) had an indication for anticoagulation pre-TAVR and 92 (70% of those with an indication) were on treatment. On discharge, 106 patients (44% of total surviving to discharge, 73% of those surviving with an indication for anticoagulation) were treated with oral anticoagulation. Of these patients, 89 (84%) were discharged on aspirin and an oral anticoagulant without clopidogrel. Only 122 (51% of total patients) were discharged on the regimen of aspirin and clopidogrel alone. Peri-procedural antithrombotic regimens vary greatly following TAVR. More than half of patients have an indication for anticoagulation following the procedure. Most patients at our institution who require anticoagulation are discharged on aspirin and an oral anticoagulant, though the optimal regimen requires further investigation.
Indexing and retrieving DICOM data in disperse and unstructured archives.
Costa, Carlos; Freitas, Filipe; Pereira, Marco; Silva, Augusto; Oliveira, José L
2009-01-01
This paper proposes an indexing and retrieval solution to gather information from distributed DICOM documents by allowing searches and access to the virtual data repository using a Google-like process. The medical imaging modalities are becoming more powerful and less expensive. The result is the proliferation of equipment acquisition by imaging centers, including the small ones. With this dispersion of data, it is not easy to take advantage of all the information that can be retrieved from these studies. Furthermore, many of these small centers do not have large enough requirements to justify the acquisition of a traditional PACS. A peer-to-peer PACS platform to index and query DICOM files over a set of distributed repositories that are logically viewed as a single federated unit. The solution is based on a public domain document-indexing engine and extends traditional PACS query and retrieval mechanisms. This proposal deals well with complex searching requirements, from a single desktop environment to distributed scenarios. The solution performance and robustness were demonstrated in trials. The characteristics of presented PACS platform make it particularly important for small institutions, including educational and research groups.
Overview of Conceptual Design of Early VentureStar(TM) Configurations
NASA Technical Reports Server (NTRS)
Lockwood, M. K.
2000-01-01
One of NASA's goals is to enable commercial access to space at a cost of $1000/lb (an order of magnitude less than today's cost) by approximately 2010. Based on results from the 1994 Congressionally mandated, NASA led, Access-to-Space Study, an all rocket-powered single-stage-to-orbit reusable launch vehicle was, selected as the best option for meeting the goal. To address the technology development issues and the follow-on development of an operational vehicle, NASA initiated the X-33 program. The focus of this paper is on the contributions made by the NASA Langley Research Center (LaRC), from 1997-1998, to the conceptual design of the Lockheed Martin Skunk Work's (LMSW) operational reusable single-stage-to-orbit VentureStar(sup TM) vehicle. The LaRC effort has been in direct support of LMSW and NASA Marshall Space Flight Center (MSFC). The primary objectives have been to reduce vehicle dry weight and improve flyability of the VentureStar(sup TM) concepts. This paper will briefly describe the analysis methods used and will present several of the concepts analyzed and design trades completed.
World's Largest Gold Crystal Studied at Los Alamos
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vogel, Sven; Nakotte, Heinz
2014-04-03
When geologist John Rakovan needed better tools to investigate whether a dazzling 217.78-gram piece of gold was in fact the world's largest single-crystal specimen - a distinguishing factor that would not only drastically increase its market value but also provide a unique research opportunity - he traveled to Los Alamos National Laboratory's Lujan Neutron Scattering Center to peer deep inside the mineral using neutron diffractometry. Neutrons, different from other probes such as X-rays and electrons, are able to penetrate many centimeters deep into most materials. Revealing the inner structure of a crystal without destroying the sample - imperative, as thismore » one is worth an estimated $1.5 million - would allow Rakovan and Lujan Center collaborators Sven Vogel and Heinz Nakotte to prove that this exquisite nugget, which seemed almost too perfect and too big to be real, was a single crystal and hence a creation of nature. Its owner, who lives in the United States, provided the samples to Rakovan to assess the crystallinity of four specimens, all of which had been found decades ago in Venezuela.« less
Briganti, Francesco; Leone, Giuseppe; Ugga, Lorenzo; Marseglia, Mariano; Solari, Domenico; Caranci, Ferdinando; Mariniello, Giuseppe; Maiuri, Francesco; Cappabianca, Paolo
2016-09-01
Experience with the endovascular treatment of cerebral aneurysms by the Flow Re-Direction Endoluminal Device (FRED) is still limited. The aim of this study is to discuss the results and complications of this new flow diverter device (FDD). Between November 2013 and April 2015, 20 patients (15 female and five male) harboring 24 cerebral aneurysms were treated with FRED FDD in a single center. Complete occlusion was obtained in 20/24 aneurysms (83 %) and partial occlusion in four (17 %). Intraprocedural technical complication occurred in one case (4 %) and post-procedural complications in three (12 %). None reported neurological deficits (mRS = 0). All FRED were patent at follow-up. No early or delayed aneurysm rupture, no subarachnoid (SAH) or intraparenchymal hemorrhage (IPH) no ischemic complications and no deaths occurred. Endovascular treatment with FRED FDD is a safe treatment for unruptured cerebral aneurysms, resulting in a high rate of occlusion. The FRED is substantially equivalent to the other known FDDs, which show similar functions and technical profiles.
World's Largest Gold Crystal Studied at Los Alamos
Vogel, Sven; Nakotte, Heinz
2018-02-07
When geologist John Rakovan needed better tools to investigate whether a dazzling 217.78-gram piece of gold was in fact the world's largest single-crystal specimen - a distinguishing factor that would not only drastically increase its market value but also provide a unique research opportunity - he traveled to Los Alamos National Laboratory's Lujan Neutron Scattering Center to peer deep inside the mineral using neutron diffractometry. Neutrons, different from other probes such as X-rays and electrons, are able to penetrate many centimeters deep into most materials. Revealing the inner structure of a crystal without destroying the sample - imperative, as this one is worth an estimated $1.5 million - would allow Rakovan and Lujan Center collaborators Sven Vogel and Heinz Nakotte to prove that this exquisite nugget, which seemed almost too perfect and too big to be real, was a single crystal and hence a creation of nature. Its owner, who lives in the United States, provided the samples to Rakovan to assess the crystallinity of four specimens, all of which had been found decades ago in Venezuela.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kalinina, N.A.
1959-01-01
At the end of pregnancy (24th to 27th day) rabbits were subjected to a single total x-ray irradiation of 600 r or to irradiation of the anterior pad of the body of 1200 r. The reaction of the fetuses to asphyxia caused by ligature of the umbilical cords was studied 24 and 72 hours after the irradiation: the time to the first asphyxiated inspiration, the number of respirations, and the time to the last respiratory movement (the characteristics of the condition of the respiratory centers) and the length of life. Both total irradiation and the irradiation of the anterior partmore » of the animal body increased the excitation of the fetal respiratory centers, which was replaced by depression in 72 hours. The delay in the fetal development can be noticed by their weight in 72 hours. These data demonstrate that the changes in the condition of the organism after the irradiation have an injurious effect on the fetuses (even on those which were not subjected to direct irradiation). (auth)« less
Chen, Yiyin; Funk, Marjorie; Wen, Jia; Tang, Xianghua; He, Guixiang; Liu, Hong
Multidisciplinary disease management programs (MDMP) for patients with heart failure (HF) have been delivered, but evidence of their effectiveness in China is limited. To determine if a MDMP improves quality of life (QoL), physical performance, depressive symptoms, self-care behaviors and mortality or rehospitalization in patients with HF in China. This is a randomized controlled single center trial in which patients with HF received either MDMP with discharge education, physical training, follow-up visits and telephone calls for 180 days (n = 31) or standard care (SC, n = 31). Compared with SC, QoL, depressive symptoms, and self-care behaviors were significantly improved by MDMP from baseline to 180 days (37% vs 66%, 20% vs 61%, and 8% vs 33%, respectively, all p < 0.001). There were no differences in physical performance and mortality or rehospitalization during follow-up. A HF MDMP can improve QoL, depressive symptoms and self-care behaviors in China. Copyright © 2017 Elsevier Inc. All rights reserved.
Role of surgical treatment in breast cancer liver metastases: a single center experience.
Bacalbasa, Nicolae; Dima, Simona Olimpia; Purtan-Purnichescu, Raluca; Herlea, Vlad; Popescu, Irinel
2014-10-01
The aim of the present study was to review a single hepatobiliary center experience, the benefit of hepatic metastasectomy in breast cancer liver metastases (BCLM) patients and to identify predictors of survival. Fifty-two female patients underwent surgery for BCLM between 2002 and 2013. Only patients with liver resections (n=43) were included in the analysis. The median survival of the 43 patients with liver resection was 32.2 months. The factors significantly associated with overall post-hepatectomy survival were estrogen/progesteron receptor (ER/PR) status (p=0.002), node involvement of the primary tumor (p=0.049), size (p=0.005) and number (p=0.006) of the metastatic lesions. The 1-, 3- and 5-year survival rates after curative liver resection were 93.02%, 74.42%, 58.14%, respectively. BCLM resection is a safe procedure and offers survival benefit, especially in patients with reduced liver metastatic burden (solitary metastases, diameter of the metastases <5 cm) and positive ER/PR status. Copyright© 2014 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved.
Gibb, Adam; Jones, Craig; Bloor, Adrian; Kulkarni, Samar; Illidge, Tim; Linton, Kim; Radford, John
2013-01-01
The CD30-targeted agent brentuximab vedotin has shown impressive activity in relapsed/refractory Hodgkin lymphoma and anaplastic large cell lymphoma in phase II studies. We have treated 24 patients with relapsed/refratory disease enrolled onto a Named Patient Programme during 2010-11 at a single UK center. Overall response rate across all histologies was 67% (Hodgkin 72%; anaplastic large cell 60%), complete response rate 25% (Hodgkin 17%; anaplastic large cell 60%), median progression-free survival 5.1 months, and toxicity mild to moderate in the majority of cases. Six patients proceeded to allogeneic transplantation and one patient awaits this procedure. These results are similar to phase II data and show that brentuximab vedotin provides a bridge to allogeneic transplantation in approximately one quarter of patients refractory to conventional salvage therapies. Best response was seen after four doses, so consideration of allogeneic transplantation should be made early and scheduled following the first assessment indicating response. PMID:23065511
Scientist, Single Cell Analysis Facility | Center for Cancer Research
The Cancer Research Technology Program (CRTP) develops and implements emerging technology, cancer biology expertise and research capabilities to accomplish NCI research objectives. The CRTP is an outward-facing, multi-disciplinary hub purposed to enable the external cancer research community and provides dedicated support to NCI’s intramural Center for Cancer Research (CCR).