16 CFR Appendix H to Part 305 - Cooling Performance and Cost for Central Air Conditioners
Code of Federal Regulations, 2014 CFR
2014-01-01
... for Central Air Conditioners Manufacturer's rated cooling capacities (Btu's/hr.) Range of SEER's Low High Single Package Units Central Air Conditioners (Cooling Only): All capacities 10.6 16.5 Heat Pumps (Cooling Function): All capacities 10.6 16.0 Split System Units Central Air Conditioners (Cooling Only...
Solar heating and cooling systems design and development
NASA Technical Reports Server (NTRS)
1977-01-01
The development and delivery of eight prototype solar heating and cooling systems for installation and operational test was reported. Two heating and six heating and cooling units will be delivered for single family residences, multiple family residences and commercial applications.
Liu, Chengtang; Mu, Yujing; Zhang, Chenglong; Zhang, Zhibo; Zhang, Yuanyuan; Liu, Junfeng; Sheng, Jiujiang; Quan, Jiannong
2016-01-04
A liquid nitrogen-free GC-FID system equipped with a single column has been developed for measuring atmospheric C2-C12 hydrocarbons. The system is consisted of a cooling unit, a sampling unit and a separation unit. The cooling unit is used to meet the temperature needs of the sampling unit and the separation unit. The sampling unit includes a dehydration tube and an enrichment tube. No breakthrough of the hydrocarbons was detected when the temperature of the enrichment tube was kept at -90 °C and sampling volume was 400 mL. The separation unit is a small round oven attached on the cooling column. A single capillary column (OV-1, 30 m × 0.32 mm I.D.) was used to separate the hydrocarbons. An optimal program temperature (-60 ∼ 170 °C) of the oven was achieved to efficiently separate C2-C12 hydrocarbons. There were good linear correlations (R(2)=0.993-0.999) between the signals of the hydrocarbons and the enrichment amount of hydrocarbons, and the relative standard deviation (RSD) was less than 5%, and the method detection limits (MDLs) for the hydrocarbons were in the range of 0.02-0.10 ppbv for sampling volume of 400 mL. Field measurements were also conducted and more than 50 hydrocarbons from C2 to C12 were detected in Beijing city. Copyright © 2015 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Munk, Jeffrey D; Odukomaiya, Adewale O; Gehl, Anthony C
2014-01-01
With the recent advancements in the application of variable-speed (VS) compressors to residential HVAC systems, opportunities are now available to size heat pumps (HPs) to more effectively meet heating and cooling loads in many of the climate zones in the US with limited use of inefficient resistance heat. This is in contrast to sizing guidance for traditional single-speed HPs that limits the ability to oversize with regard to cooling loads, because of risks of poor dehumidification during the cooling season and increased cycling losses. VS-drive HPs can often run at 30-40% of their rated cooling capacity to reduce cycling losses,more » and can adjust fan speed to provide better indoor humidity control. Detailed air-side performance data was collected on two VS-drive heat pumps installed in a single unoccupied research house in Knoxville, TN, a mixed-humid climate. One system provided space conditioning for the upstairs, while the other unit provided space conditioning for the downstairs. Occupancy was simulated by operating the lights, shower, appliances, other plug loads, etc. to simulate the sensible and latent loads imposed on the building space by internal electric loads and human occupants according to the Building America Research Benchmark (2008). The seasonal efficiency and energy use of the units are calculated. Annual energy use is compared to that of the single speed minimum efficiency HPs tested in the same house previously. Sizing of the units relative to the measured building load and manual J design load calculations is examined. The impact of the unit sizing with regards to indoor comfort is also evaluated.« less
NASA Astrophysics Data System (ADS)
Sant, T.; Buhagiar, D.; Farrugia, R. N.
2014-06-01
A new concept utilising floating wind turbines to exploit the low temperatures of deep sea water for space cooling in buildings is presented. The approach is based on offshore hydraulic wind turbines pumping pressurised deep sea water to a centralised plant consisting of a hydro-electric power system coupled to a large-scale sea water-cooled air conditioning (AC) unit of an urban district cooling network. In order to investigate the potential advantages of this new concept over conventional technologies, a simplified model for performance simulation of a vapour compression AC unit was applied independently to three different systems, with the AC unit operating with (1) a constant flow of sea surface water, (2) a constant flow of sea water consisting of a mixture of surface sea water and deep sea water delivered by a single offshore hydraulic wind turbine and (3) an intermittent flow of deep sea water pumped by a single offshore hydraulic wind turbine. The analysis was based on one year of wind and ambient temperature data for the Central Mediterranean that is known for its deep waters, warm climate and relatively low wind speeds. The study confirmed that while the present concept is less efficient than conventional turbines utilising grid-connected electrical generators, a significant portion of the losses associated with the hydraulic transmission through the pipeline are offset by the extraction of cool deep sea water which reduces the electricity consumption of urban air-conditioning units.
NASA Astrophysics Data System (ADS)
Mysore, Abhishek Arun Babu
A medium data center consists of servers performing operations such as file sharing, collaboration and email. There are a large number of small and medium data centers across the world which consume more energy and are less efficient when compared to large data center facilities of companies such as GOOGLE, APPLE and FACEBOOK. Such companies are making their data center facilities more environmental friendly by employing renewable energy solutions such as wind and solar to power the data center or in data center cooling. This not only reduces the carbon footprint significantly but also decreases the costs incurred over a period of time. Cooling of data center play a vital role in proper functioning of the servers. It is found that cooling consumes about 50% of the total power consumed by the data center. Traditional method of cooling includes the use of mechanical compression chillers which consume lot of power and is not desirable. In order to eliminate the use of mechanical compressor chillers renewable energy resources such as solar and wind should be employed. One such technology is solar thermal cooling by means of absorption chiller which is powered by solar energy. The absorption chiller unit can be coupled with either flat plate or evacuated tube collectors in order to achieve the required inlet temperature for the generator of the absorption chiller unit. In this study a modular data center is considered having a cooling load requirement of 23kw. The performance characteristics of a single stage Lithium Bromide/ water refrigeration is presented in this study considering the cooling load of 23kw. Performance characteristics of each of the 4 heat exchangers within the unit is discussed which helps in customizing the unit according to the users' specific needs. This analysis helps in studying the importance of different properties such as the effect of inlet temperatures of hot water for generator, inlet temperatures of cooling water for absorber and condenser and outlet chilled water temperatures of the evaporator.
Development status of a high cooling capacity single stage pulse tube cryocooler
NASA Astrophysics Data System (ADS)
Hirayama, T.; Li, R.; Y Xu, M.; Zhu, S. W.
2017-12-01
High temperature superconducting (HTS) applications require high-capacity and high-reliability cooling solutions to keep HTS materials at temperatures of approximately 80 K. In order to meet such requirements, Sumitomo Heavy Industries, Ltd.(SHI) has been developing high cooling capacity GM-type active-buffer pulse tube cryocooler. An experimental unit was designed, built and tested. A cooling capacity of 390.5 W at 80 K, COP 0.042 was achieved with an input power of approximately 9 kW. The cold stage usually reaches a stable temperature of about 25 K within one hour starting at room temperature. Also, a simplified analysis was carried out to better understand the experimental unit. In the analysis, the regenerator, thermal conduction, heat exchanger and radiation losses were calculated. The net cooling capacity was about 80% of the PV work. The experimental results, the analysis method and results are reported in this paper.
NASA Astrophysics Data System (ADS)
Zhao, Dongliang
The thermoelectric cooling system has advantages over conventional vapor compression cooling devices, including compact in size, light in weight, high reliability, no mechanical moving parts, no refrigerant, being powered by direct current, and easily switching between cooling and heating modes. However, it has been long suffering from its relatively high cost and low energy efficiency, which has restricted its usage to niche applications, such as space missions, portable cooling devices, scientific and medical equipment, where coefficient of performance (COP) is not as important as reliability, energy availability, and quiet operation environment. Enhancement of thermoelectric cooling system performance generally relies on two methods: improving thermoelectric material efficiency and through thermoelectric cooling system thermal design. This research has been focused on the latter one. A prototype thermoelectric cooling system integrated with phase change material (PCM) thermal energy storage unit for space cooling has been developed. The PCM thermal storage unit used for cold storage at night, functions as the thermoelectric cooling system's heat sink during daytime's cooling period and provides relatively lower hot side temperature for the thermoelectric cooling system. The experimental test of the prototype system in a reduced-scale chamber has realized an average cooling COP of 0.87, with the maximum value of 1.22. Another comparison test for efficacy of PCM thermal storage unit shows that 35.3% electrical energy has been saved from using PCM for the thermoelectric cooling system. In general, PCM faces difficulty of poor thermal conductivity at both solid and liquid phases. This system implemented a finned inner tube to increase heat transfer during PCM charging (melting) process that directly impacts thermoelectric system's performance. A simulation tool for the entire system has been developed including mathematical models for a single thermoelectric module, for the thermoelectric cooling unit, for the PCM thermal storage unit, and for the outdoor air-water heat exchanger. When modeling PCM thermal storage unit, the enthalpy method has been adopted. Since natural convection has been observed in experiments playing a key effect on heat transfer in PCM, a staged effective thermal conductivity (ke) concept and modified Rayleigh (Ra) number formula have been developed to better capture natural convection's variable effects during the PCM charging process. Therefore, a modeling-based design procedure for thermoelectric cooling system integrating with PCM has been proposed. A case study has been completed for a model office room to demonstrate the qualitative and quantitative evaluations to the major system components. Results of this research can be extended to other applications in relevant areas. For instance, the proposed PCM thermal storage unit can be applied to integration with water-cooled conventional air-conditioning devices. Instead of using water cooling, a case study of using the proposed PCM unit for a water-cooled air-conditioner shows a COP increase of more than 25.6%.
NASA Technical Reports Server (NTRS)
Shirron, Peter J.
2014-01-01
Adiabatic demagnetization refrigerators (ADR), based on the magnetocaloric effect, are solid-state coolers that were the first to achieve cooling well into the sub-kelvin regime. Although supplanted by more powerful dilution refrigerators in the 1960s, ADRs have experienced a revival due to the needs of the space community for cooling astronomical instruments and detectors to temperatures below 100 mK. The earliest of these were single-stage refrigerators using superfluid helium as a heat sink. Their modest cooling power (<1 µW at 60 mK[1]) was sufficient for the small (6x6) detector arrays[2], but recent advances in arraying and multiplexing technologies[3] are generating a need for higher cooling power (5-10 µW), and lower temperature (<30 mK). Single-stage ADRs have both practical and fundamental limits to their operating range, as mass grows very rapidly as the operating range is expanded. This has led to the development of new architectures that introduce multi-staging as a way to improve operating range, efficiency and cooling power. Multi-staging also enables ADRs to be configured for continuous operation, which greatly improves cooling power per unit mass. This paper reviews the current field of adiabatic demagnetization refrigeration, beginning with a description of the magnetocaloric effect and its application in single-stage systems, and then describing the challenges and capabilities of multi-stage and continuous ADRs.
Cooling, degassing and compaction of rhyolitic ash flow tuffs: a computational model
Riehle, J.R.; Miller, T.F.; Bailey, R.A.
1995-01-01
Previous models of degassing, cooling and compaction of rhyolitic ash flow deposits are combined in a single computational model that runs on a personal computer. The model applies to a broader range of initial and boundary conditions than Riehle's earlier model, which did not integrate heat and mass flux with compaction and which for compound units was limited to two deposits. Model temperatures and gas pressures compare well with simple measured examples. The results indicate that degassing of volatiles present at deposition occurs within days to a few weeks. Compaction occurs for weeks to two to three years unless halted by devitrification; near-emplacement temperatures can persist for tens of years in the interiors of thick deposits. Even modest rainfall significantly chills the upper parts of ash deposits, but compaction in simple cooling units ends before chilling by rainwater influences cooling of the interior of the sheet. Rainfall does, however, affect compaction at the boundaries of deposits in compound cooling units, because the influx of heat from the overlying unit is inadequate to overcome heat previously lost to vaporization of water. Three density profiles from the Matahina Ignimbrite, a compound cooling unit, are fairly well reproduced by the model despite complexities arising from numerous cooling breaks. Uncertainties in attempts to correlate in detail among the profiles may be the result of the non-uniform distribution of individual deposits. Regardless, it is inferred that model compaction is approximately valid. Thus the model should be of use in reconstructing the emplacement history of compound ash deposits, for inferring the depositional environments of ancient deposits and for assessing how long deposits of modern ash flows are capable of generating phreatic eruptions or secondary ash flows. ?? 1995 Springer-Verlag.
Orton, Llwyd D.; Poon, Paul W. F.; Rees, Adrian
2012-01-01
The auditory pathways coursing through the brainstem are organized bilaterally in mirror image about the midline and at several levels the two sides are interconnected. One of the most prominent points of interconnection is the commissure of the inferior colliculus (CoIC). Anatomical studies have revealed that these fibers make reciprocal connections which follow the tonotopic organization of the inferior colliculus (IC), and that the commissure contains both excitatory and, albeit fewer, inhibitory fibers. The role of these connections in sound processing is largely unknown. Here we describe a method to address this question in the anaesthetized guinea pig. We used a cryoloop placed on one IC to produce reversible deactivation while recording electrophysiological responses to sounds in both ICs. We recorded single units, multi-unit clusters and local field potentials (LFPs) before, during and after cooling. The degree and spread of cooling was measured with a thermocouple placed in the IC and other auditory structures. Cooling sufficient to eliminate firing was restricted to the IC contacted by the cryoloop. The temperature of other auditory brainstem structures, including the contralateral IC and the cochlea were minimally affected. Cooling below 20°C reduced or eliminated the firing of action potentials in frequency laminae at depths corresponding to characteristic frequencies up to ~8 kHz. Modulation of neural activity also occurred in the un-cooled IC with changes in single unit firing and LFPs. Components of LFPs signaling lemniscal afferent input to the IC showed little change in amplitude or latency with cooling, whereas the later components, which likely reflect inter- and intra-collicular processing, showed marked changes in form and amplitude. We conclude that the cryoloop is an effective method of selectively deactivating one IC in guinea pig, and demonstrate that auditory processing in the IC is strongly influenced by the other. PMID:23248587
Preliminary design package for prototype solar heating and cooling systems
NASA Technical Reports Server (NTRS)
1978-01-01
A summary is given of the preliminary analysis and design activity on solar heating and cooling systems. The analysis was made without site specific data other than weather; therefore, the results indicate performance expected under these special conditions. Major items include a market analysis, design approaches, trade studies and other special data required to evaluate the preliminary analysis and design. The program calls for the development and delivery of eight prototype solar heating and cooling systems for installation and operational test. Two heating and six heating and cooling units will be delivered for Single Family Residences, Multiple-family Residences and commercial applications.
NASA Technical Reports Server (NTRS)
1980-01-01
Installation procedures for the single family residential solar heating system at the William O'Brien State Park, Stillwater, Minnesota, are presented. The system is a solar-assisted, hydronic-to-warm-air system with solar-assisted domestic water heating. It is composed of the following major components: liquid cooled flat plate collectors; water storage tank; passive solar-fired domestic water preheater; electric hot water heater; heat pump with electric backup; solar hot water coil unit; tube-and-shell heat exchanger, three pumps, and associated pipes and valving in an energy transport module; control system; and air-cooled heat purge unit. Installer guidelines are provided for each subsystem and includes testing and filling the system. Information is also given on the operating procedures, controls, caution requirements and routine and schedule maintenance.
NASA Technical Reports Server (NTRS)
1980-01-01
The solar heating system installer guidelines are presented for each subsystem. This single family residential heating system is a solar-assisted, hydronic-to-warm-air system with solar-assisted domestic water heating. It is composed of the following major components: (1) liquid cooled flat plate collectors; (2) water storage tank; (3) passive solar-fired domestic water preheater; (4) electric hot water heater; (5) heat pump with electric backup; (6) solar hot water coil unit; (7) tube-and-shell heat exchanger, three pumps, and associated pipes and valving in an energy transport module; (8) control system; and (9) air-cooled heat purge unit. Information is provided on the operating procedures, controls, caution requirements, and routine and schedule maintenance in the form of written descriptions, schematics, detail drawings, pictures, and manufacturer's component data.
NASA Astrophysics Data System (ADS)
Hiratsuka, Y.; Bao, Q.; Y Xu, M.
2017-12-01
Since 2012, a new, compact Gifford-McMahon (GM) cryocooler for cooling superconducting single photon detectors (SSPD) has been developed and reported by Sumitomo Heavy Industries, Ltd. (SHI). Also, it was reported that National Institute of Information and Communications Technology (NICT) developed a multi-channel, conduction-cooled SSPD system. However, the size and power consumption reduction becomes indispensable to apply such a system to the optical communication of AdHoc for a mobile system installed in a vehicle. The objective is to reduce the total height of the expander by 33% relative to the existing RDK-101 GM expander and to reduce the total volume of the compressor unit by 50% relative to the existing CNA-11 compressor. In addition, considering the targeted cooling application, we set the design cooling capacity targets of the first and the second stages 1 W at 60 K and 20 mW at 2.3 K respectively. In 2016, Hiratsuka et al. reported that an oil-free compressor was developed for a 2K GM cryocooler. The cooling performance of a 2K GM expander driven by an experimental unit of the linear compressor was measured. No-load temperature less than 2.1 K and the cooling capacity of 20 mW at 2.3 K were successfully achieved with an electric input power of only 1.1 kW. After that, the compressor capsule and the heat exchanger, etc. were assembled into one enclosure as a compressor unit. The total volume of the compressor unit and electrical box was significantly reduced to about 38 L, which was close to the target of 35 L. Also, the sound noise, vibration characteristics, the effect of the compressor unit inclination and the ambient temperature on the cooling performance, were evaluated. The detailed experimental results are discussed in this paper.
Physical and Structural Studies on the Cryo-cooling of Insulin Crystals
NASA Technical Reports Server (NTRS)
Lovelace, J.; Bellamy, H.; Snell, E. H.; Borgstahl, G.
2003-01-01
Reflection profiles were analyzed from microgravity-(mg) and earth-grown insulin crystals to measure mosaicity (h) and to reveal mosaic domain structure and composition. The effects of cryocooling on single and multi-domain crystals were compared. The effects of cryocooling on insulin structure were also re-examined. Microgravity crystals were larger, more homogeneous, and more perfect than earth crystals. Several mg crystals contained primarily a single mosaic domain with havg of 0.005deg. The earth crystals varied in quality and all contained multiple domains with havg of 0.031deg. Cryocooling caused a 43-fold increase in h for mg crystals (havg=0.217deg) and an %fold increase for earth crystals (havg=0.246deg). These results indicate that very well-ordered crystals are not completely protected from the stresses associated with cryocooling, especially when structural perturbations occur. However, there were differences in the reflection profiles. For multi-mosaic domain crystals, each domain individually broadened and separated from the other domains upon cryo-cooling. Cryo-cooling did not cause an increase in the number of domains. A crystal composed of a single domain retained this domain structure and the reflection profiles simply broadened. Therefore, an improved signal-to-noise ratio for each reflection was measured from cryo-cooled single domain crystals relative to cryo-cooled multi-domain crystals. This improved signal, along with the increase in crystal size, facilitated the measurement of the weaker high- resolution reflections. The observed broadening of reflection profiles indicates increased variation in unit cell dimensions which may be linked to cryo-cooling-associated structural changes and disorder.
Bringing Solid-State Magnetocaloric Cooling to the Market: A Commercialization Plan
DOE Office of Scientific and Technical Information (OSTI.GOV)
Abu-Heiba, Ahmad; Sikes, Karen; Blackburn, Julia
Air conditioning has become a staple in American life, bringing improved health, productivity, and comfort to 93% of single-family homes as of 2015, compared to only 76% in 1990. This rise in demand has contributed to the 2.51 quads (12.5%) of total annual energy consumption in residential buildings attributable to space cooling (U.S. Energy Information Administration 2017). Accompanying this upward trend in space cooling has been increased refrigerant use, which has historically contributed to ozone depletion, global warming, or both. The Oak Ridge National Laboratory – along with German-based partner Vacuumschmelze GmbH & Co. KG – is working to reducemore » energy consumption and refrigerant use through the development of a next-generation, solid-state magnetocaloric cooling system. The purpose of this study is to investigate market potential of these systems in the United States, including information on the industry landscape, market share and unit shipment projections, optimal price points, and barriers to market entry.« less
"Heating up" or "Cooling up" the Brain? MEG Evidence that Phrasal Verbs Are Lexical Units
ERIC Educational Resources Information Center
Cappelle, Bert; Shtyrov, Yury; Pulvermuller, Friedemann
2010-01-01
There is a considerable linguistic debate on whether phrasal verbs (e.g., "turn up," "break down") are processed as two separate words connected by a syntactic rule or whether they form a single lexical unit. Moreover, views differ on whether meaning (transparency vs. opacity) plays a role in determining their syntactically-connected or lexical…
Liu, Chongbin; Li, Rende; Liu, Zhonghu; Yin, Shuming; Wang, Ziren
2006-05-01
Typically, small lizards rely heavily on behavioral thermoregulation rather than physiological mechanisms to control their rates of warming and cooling. We tested the hypothesis that prostaglandins participate in mediating the cardiovascular response to heating and cooling and temperature regulating neurons in the hypothalamus of the small lizard Phrynocephalus przewalskii. In vivo and in vitro treatments, heart rates (HRs) were all found to be higher during heating than during cooling, hysteresis was distinct below 30 and 26 degrees Celsius, respectively. In vivo, as administration of COX inhibitor, there were no differences in HR between heating and cooling at any body temperature and administration of agonist prostaglandins only produced a significant effect on HR below 25 degrees Celsius. Single-unit activity was recorded extracellularly in vitro with microelectrodes, found the firing rate of the continuous unit increased 23% when the temperature of the artificial cerebrospinal fluid dropped from 30-20 degrees Celsius. We conclude that prostaglandins appear to play only a limited role in modulating heart activity in Phrynocephalus przewalskii and suggest that cold-sensitive neurons in the preoptic and anterior hypothalamus (PO/AH) are involved in thermoregulatory control during heating or cooling.
Microwave lamp with multi-purpose rotary motor
Ury, Michael G.; Turner, Brian; Wooten, Robert D.
1999-01-01
In a microwave powered electrodeless lamp, a single rotary motor is used to a) rotate the bulb and b) provide rotary motion to a blower or pump means for providing cooling fluid to the magnetron and/or to a forced gas cooling for providing cooler gas to the bulb. The blower may consist of only of an impeller without the usual blower housing. The motor, bulb stem and bulb, or motor, bulb stem, bulb and blower may be formed as an integral unit so as to facilitate replacement.
Effect of Cooling Units on the Performance of an Automotive Exhaust-Based Thermoelectric Generator
NASA Astrophysics Data System (ADS)
Su, C. Q.; Zhu, D. C.; Deng, Y. D.; Wang, Y. P.; Liu, X.
2017-05-01
Currently, automotive exhaust-based thermoelectric generators (AETEGs) are a hot topic in energy recovery. In order to investigate the influence of coolant flow rate, coolant flow direction and cooling unit arrangement in the AETEG, a thermoelectric generator (TEG) model and a related test bench are constructed. Water cooling is adopted in this study. Due to the non-uniformity of the surface temperature of the heat source, the coolant flow direction would affect the output performance of the TEG. Changing the volumetric flow rate of coolant can increase the output power of multi-modules connected in series or/and parallel as it can improve the temperature uniformity of the cooling unit. Since the temperature uniformity of the cooling unit has a strong influence on the output power, two cooling units are connected in series or parallel to research the effect of cooling unit arrangements on the maximum output power of the TEG. Experimental and theoretical analyses reveal that the net output power is generally higher with cooling units connected in parallel than cooling units connected in series in the cooling system with two cooling units.
System solution to improve energy efficiency of HVAC systems
NASA Astrophysics Data System (ADS)
Chretien, L.; Becerra, R.; Salts, N. P.; Groll, E. A.
2017-08-01
According to recent surveys, heating and air conditioning systems account for over 45% of the total energy usage in US households. Three main types of HVAC systems are available to homeowners: (1) fixed-speed systems, where the compressor cycles on and off to match the cooling load; (2) multi-speed (typically, two-speed) systems, where the compressor can operate at multiple cooling capacities, leading to reduced cycling; and (3) variable-speed systems, where the compressor speed is adjusted to match the cooling load of the household, thereby providing higher efficiency and comfort levels through better temperature and humidity control. While energy consumption could reduce significantly by adopting variable-speed compressor systems, the market penetration has been limited to less than 10% of the total HVAC units and a vast majority of systems installed in new construction remains single speed. A few reasons may explain this phenomenon such as the complexity of the electronic circuitry required to vary compressor speed as well as the associated system cost. This paper outlines a system solution to boost the Seasonal Energy Efficiency Rating (SEER) of a traditional single-speed unit through using a low power electronic converter that allows the compressor to operate at multiple low capacity settings and is disabled at high compressor speeds.
NASA Astrophysics Data System (ADS)
Liu, Yongfeng; Lehnert, Werner; Janßen, Holger; Samsun, Remzi Can; Stolten, Detlef
2016-04-01
This paper presents an extensive review of research on the development of auxiliary power units with enhanced reformate tolerance for high temperature polymer electrolyte membrane fuel cells (HT-PEMFCs). Developments in diesel reforming for fuel cells as auxiliary power units (APUs), single fuel cells and stacks and systems are outlined in detail and key findings are presented. Summaries of HT-PEMFC APU applications and start-up times for HT-PEMFC systems are then given. A summary of cooling HT-PEMFC stacks using a classic schematic diagram of a 24-cell HT-PEMFC stack, with a cooling plate for every third cell, is also presented as part of a stack analysis. Finally, a summary of CO tolerances for fuel cells is given, along with the effects of different CO volume fractions on polarization curves, the fraction of CO coverage, hydrogen coverage, anode overpotential and cell potential.
Microwave lamp with multi-purpose rotary motor
Ury, M.G.; Turner, B.; Wooten, R.D.
1999-02-02
In a microwave powered electrodeless lamp, a single rotary motor is used to (a) rotate the bulb and (b) provide rotary motion to a blower or pump means for providing cooling fluid to the magnetron and/or to a forced gas cooler for providing cooling gas to the bulb. The blower may consist of only of an impeller without the usual blower housing. The motor, bulb stem and bulb, or motor, bulb stem, bulb and blower may be formed as an integral unit so as to facilitate replacement. 8 figs.
Compact atom interferometer using single laser
NASA Astrophysics Data System (ADS)
Chiow, Sheng-wey; Yu, Nan
2018-06-01
A typical atom interferometer requires vastly different laser frequencies at different stages of operation, e.g., near resonant light for laser cooling and far detuned light for atom optics, such that multiple lasers are typically employed. The number of laser units constrains the achievable minimum size and power in practical devices for resource critical environments such as space. We demonstrate a compact atom interferometer accelerometer operated by a single diode laser. This is achieved by dynamically changing the laser output frequency in GHz range while maintaining spectroscopic reference to an atomic transition via a sideband generated by phase modulation. At the same time, a beam path sharing configuration is also demonstrated for a compact sensor head design, in which atom interferometer beams share the same path as that of the cooling beam. This beam path sharing also significantly simplifies three-axis atomic accelerometry in microgravity using single sensor head.
A thermodynamic analysis of a novel bidirectional district heating and cooling network
Zarin Pass, R.; Wetter, M.; Piette, M. A.
2017-11-29
In this study, we evaluate an ambient, bidirectional thermal network, which uses a single circuit for both district heating and cooling. When in net more cooling is needed than heating, the system circulates from a central plant in one direction. When more heating is needed, the system circulates in the opposite direction. A large benefit of this design is that buildings can recover waste heat from each other directly. We analyze the thermodynamic performance of the bidirectional system. Because the bidirectional system represents the state-of-the-art in design for district systems, its peak energy efficiency represents an upper bound on themore » thermal performance of any district heating and cooling system. However, because any network has mechanical and thermal distribution losses, we develop a diversity criterion to understand when the bidirectional system may be a more energy-efficient alternative to modern individual-building systems. We show that a simple model of a low-density, high-distribution loss network is more efficient than aggregated individual buildings if there is at least 1 unit of cooling energy per 5.7 units of simultaneous heating energy (or vice versa). We apply this criterion to reference building profiles in three cities to look for promising clusters.« less
A thermodynamic analysis of a novel bidirectional district heating and cooling network
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zarin Pass, R.; Wetter, M.; Piette, M. A.
In this study, we evaluate an ambient, bidirectional thermal network, which uses a single circuit for both district heating and cooling. When in net more cooling is needed than heating, the system circulates from a central plant in one direction. When more heating is needed, the system circulates in the opposite direction. A large benefit of this design is that buildings can recover waste heat from each other directly. We analyze the thermodynamic performance of the bidirectional system. Because the bidirectional system represents the state-of-the-art in design for district systems, its peak energy efficiency represents an upper bound on themore » thermal performance of any district heating and cooling system. However, because any network has mechanical and thermal distribution losses, we develop a diversity criterion to understand when the bidirectional system may be a more energy-efficient alternative to modern individual-building systems. We show that a simple model of a low-density, high-distribution loss network is more efficient than aggregated individual buildings if there is at least 1 unit of cooling energy per 5.7 units of simultaneous heating energy (or vice versa). We apply this criterion to reference building profiles in three cities to look for promising clusters.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2010-09-09
... facility, a wind farm, a methane- gas cofiring facility, and several small solar photovoltaic facilities... maintenance of select plant systems and other regulatory compliance activities. Major buildings and plant... the plant cooling towers and the reactor, auxiliary, control, turbine, office, and service buildings...
NASA Astrophysics Data System (ADS)
Bhojwani, Virendra; Inamdar, Asif; Lele, Mandar; Tendolkar, Mandar; Atrey, Milind; Bapat, Shridhar; Narayankhedkar, Kisan
2017-04-01
A two-stage Stirling Cryocooler has been developed and tested for cooling IR sensors in space application. The concept uses an opposed piston linear compressor to drive the two-stage Stirling expander. The configuration used a moving coil linear motor for the compressor as well as for the expander unit. Electrical phase difference of 80 degrees was maintained between the voltage waveforms supplied to the compressor motor and expander motor. The piston and displacer surface were coated with Rulon an anti-friction material to ensure oil less operation of the unit. The present article discusses analysis results, features of the cryocooler and experimental tests conducted on the developed unit. The two-stages of Cryo-cylinder and the expander units were manufactured from a single piece to ensure precise alignment between the two-stages. Flexure bearings were used to suspend the piston and displacer about its mean position. The objective of the work was to develop a two-stage Stirling cryocooler with 2 W at 120 K and 0.5 W at 60 K cooling capacity for the two-stages and input power of less than 120 W. The Cryocooler achieved a minimum temperature of 40.7 K at stage 2.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Biermann, W. J.
1978-01-01
All the available experimental evidence suggests that the optimum ''organic'' absorbent/refrigerant combination would be a methane derivative with a single hydrogen atom with chlorine and fluorine atoms in the other sites, as refrigerant. This would be hydrogen bonded to an absorbent molecule containing the group =NC/sup -/O, with the substituent groups being such that no steric hindrance took place. Cycle analyses showed that the ratio of internal heat transfer to cooling would be large, probably impractically so in view of the high coefficient of performance needed for solar driven cooling and the additional handicap of heat rejection to the atmosphere.more » A more promising approach would be to reduce the internal heat transfer per unit of space cooling by selecting a refrigerant with a high latent heat of vaporization and selecting an absorbent with suitable properties.« less
Prospective gas turbine and combined-cycle units for power engineering (a Review)
NASA Astrophysics Data System (ADS)
Ol'khovskii, G. G.
2013-02-01
The modern state of technology for making gas turbines around the world and heat-recovery combined-cycle units constructed on their basis are considered. The progress achieved in this field by Siemens, Mitsubishi, General Electric, and Alstom is analyzed, and the objectives these companies set forth for themselves for the near and more distant future are discussed. The 375-MW gas turbine unit with an efficiency of 40% produced by Siemens, which is presently the largest one, is subjected to a detailed analysis. The main specific features of this turbine are that the gas turbine unit's hot-path components have purely air cooling, due to which the installation has enhanced maneuverability. The single-shaft combined-cycle plant constructed on the basis of this turbine has a capacity of 570 MW and efficiency higher than 60%. Programs adopted by different companies for development of new-generation gas turbine units firing synthesis gas and fitted with low-emission combustion chambers and new cooling systems are considered. Concepts of rotor blades for new gas turbine units with improved thermal barrier coatings and composite blades different parts of which are made of materials selected in accordance with the conditions of their operation are discussed.
Simulation model of a single-stage lithium bromide-water absorption cooling unit
NASA Technical Reports Server (NTRS)
Miao, D.
1978-01-01
A computer model of a LiBr-H2O single-stage absorption machine was developed. The model, utilizing a given set of design data such as water-flow rates and inlet or outlet temperatures of these flow rates but without knowing the interior characteristics of the machine (heat transfer rates and surface areas), can be used to predict or simulate off-design performance. Results from 130 off-design cases for a given commercial machine agree with the published data within 2 percent.
NASA Technical Reports Server (NTRS)
Merrick, R. H.; Anderson, P. P.
1973-01-01
The possible use of solar energy powered absorption units to provide cooling and heating of residential buildings is studied. Both, the ammonia-water and the water-lithium bromide cycles, are considered. It is shown that the air cooled ammonia water unit does not meet the criteria for COP and pump power on the cooling cycle and the heat obtained from it acting as a heat pump is at too low a temperature. If the ammonia machine is water cooled it will meet the design criteria for cooling but can not supply the heating needs. The water cooled lithium bromide unit meets the specified performance for cooling with appreciably lower generator temperatures and without a mechanical solution pump. It is recommeded that in the demonstration project a direct expansion lithium bromide unit be used for cooling and an auxiliary duct coil using the solar heated water be employed for heating.
NASA Astrophysics Data System (ADS)
Hofmeister, M.; Franke, M. M.; Koerner, C.; Singer, R. F.
2017-12-01
Superalloy gas turbine blades are being produced by investment casting and directional solidification. A new process, Fluidized Carbon Bed Cooling (FCBC), has been developed and is now being optimized in a prototype casting unit with 10 kg pouring weight. In early test runs with still rather simple mold cluster geometries, a reduction of the primary dendrite arm spacing of around 40 pct compared to the standard radiation cooling process (HRS) could be demonstrated. The improvement is mainly attributed to higher temperature gradients driving solidification, made possible by a functioning Dynamic Baffle. Compared to earlier development efforts in the literature, contamination of the melt and damage to the equipment are avoided using carbon-based fluidized bed materials and the so-called "counter pressure concept."
Evaporative cooling enhanced cold storage system
Carr, Peter
1991-01-01
The invention provides an evaporatively enhanced cold storage system wherein a warm air stream is cooled and the cooled air stream is thereafter passed into contact with a cold storage unit. Moisture is added to the cooled air stream prior to or during contact of the cooled air stream with the cold storage unit to effect enhanced cooling of the cold storage unit due to evaporation of all or a portion of the added moisture. Preferably at least a portion of the added moisture comprises water condensed during the cooling of the warm air stream.
Evaporative cooling enhanced cold storage system
Carr, P.
1991-10-15
The invention provides an evaporatively enhanced cold storage system wherein a warm air stream is cooled and the cooled air stream is thereafter passed into contact with a cold storage unit. Moisture is added to the cooled air stream prior to or during contact of the cooled air stream with the cold storage unit to effect enhanced cooling of the cold storage unit due to evaporation of all or a portion of the added moisture. Preferably at least a portion of the added moisture comprises water condensed during the cooling of the warm air stream. 3 figures.
Cooling Performance Analysis of ThePrimary Cooling System ReactorTRIGA-2000Bandung
NASA Astrophysics Data System (ADS)
Irianto, I. D.; Dibyo, S.; Bakhri, S.; Sunaryo, G. R.
2018-02-01
The conversion of reactor fuel type will affect the heat transfer process resulting from the reactor core to the cooling system. This conversion resulted in changes to the cooling system performance and parameters of operation and design of key components of the reactor coolant system, especially the primary cooling system. The calculation of the operating parameters of the primary cooling system of the reactor TRIGA 2000 Bandung is done using ChemCad Package 6.1.4. The calculation of the operating parameters of the cooling system is based on mass and energy balance in each coolant flow path and unit components. Output calculation is the temperature, pressure and flow rate of the coolant used in the cooling process. The results of a simulation of the performance of the primary cooling system indicate that if the primary cooling system operates with a single pump or coolant mass flow rate of 60 kg/s, it will obtain the reactor inlet and outlet temperature respectively 32.2 °C and 40.2 °C. But if it operates with two pumps with a capacity of 75% or coolant mass flow rate of 90 kg/s, the obtained reactor inlet, and outlet temperature respectively 32.9 °C and 38.2 °C. Both models are qualified as a primary coolant for the primary coolant temperature is still below the permitted limit is 49.0 °C.
NASA Technical Reports Server (NTRS)
Erickson, Lisa R.; Ungar, Eugene K.
2013-01-01
Maximizing the reuse of wastewater while minimizing the use of consumables is critical in long duration space exploration. One of the more promising methods of reclaiming urine is the distillation/condensation process used in the cascade distillation system (CDS). This system accepts a mixture of urine and toxic stabilizing agents, heats it to vaporize the water and condenses and cools the resulting water vapor. The CDS wastewater flow requires heating and its condensate flow requires cooling. Performing the heating and cooling processes separately requires two separate units, each of which would require large amounts of electrical power. By heating the wastewater and cooling the condensate in a single heat pump unit, mass, volume, and power efficiencies can be obtained. The present work describes and compares two competing heat pump methodologies that meet the needs of the CDS: 1) a series of mini compressor vapor compression cycles and 2) a thermoelectric heat exchanger. In the paper, the system level requirements are outlined, the designs of the two heat pumps are described in detail, and the results of heat pump performance tests are provided. A summary is provided of the heat pump mass, volume and power trades and a selection recommendation is made.
Climate Change Impacts on Rivers and Implications for Electricity Generation in the United States
NASA Astrophysics Data System (ADS)
Miara, A.; Vorosmarty, C. J.; Macknick, J.; Corsi, F.; Cohen, S. M.; Tidwell, V. C.; Newmark, R. L.; Prousevitch, A.
2015-12-01
The contemporary power sector in the United States is heavily reliant on water resources to provide cooling water for thermoelectric generation. Efficient thermoelectric plant operations require large volumes of water at sufficiently cool temperatures for their cooling process. The total amount of water that is withdrawn or consumed for cooling and any potential declines in efficiencies are determined by the sector's fuel mix and cooling technologies. As such, the impact of climate change, and the extent of impact, on the power sector is shaped by the choice of electricity generation technologies that will be built over the coming decades. In this study, we model potential changes in river discharge and temperature in the contiguous US under a set of climate scenarios to year 2050 using the Water Balance Model-Thermoelectric Power and Thermal Pollution Model (WBM-TP2M). Together, these models quantify, in high-resolution (3-min), river temperatures, discharge and power plant efficiency losses associated with changes in available cooling water that incorporates climate, hydrology, river network dynamics and multi-plant impacts, on both single power plant and regional scales. Results are used to assess the aptness and vulnerability of contemporary and alternative electricity generation pathways to changes in climate and water availability for cooling purposes, and the concomitant impacts on power plant operating efficiencies. We assess the potential impacts by comparing six regions (Northeast, Southeast, Midwest, Great Plains, Southwest, Northwest as in the National Climate Assessment (2014)) across the US. These experiments allow us to assess tradeoffs among electricity-water-climate to provide useful insight for decision-makers managing regional power production and aquatic environments.
Huang, Lihan
2016-07-01
Clostridium perfringens type A is a significant public health threat and its spores may germinate, outgrow, and multiply during cooling of cooked meats. This study applies a new C. perfringens growth model in the USDA Integrated Pathogen Modeling Program-Dynamic Prediction (IPMP Dynamic Prediction) Dynamic Prediction to predict the growth from spores of C. perfringens in cooked uncured meat and poultry products using isothermal, dynamic heating, and cooling data reported in the literature. The residual errors of predictions (observation-prediction) are analyzed, and the root-mean-square error (RMSE) calculated. For isothermal and heating profiles, each data point in growth curves is compared. The mean residual errors (MRE) of predictions range from -0.40 to 0.02 Log colony forming units (CFU)/g, with a RMSE of approximately 0.6 Log CFU/g. For cooling, the end point predictions are conservative in nature, with an MRE of -1.16 Log CFU/g for single-rate cooling and -0.66 Log CFU/g for dual-rate cooling. The RMSE is between 0.6 and 0.7 Log CFU/g. Compared with other models reported in the literature, this model makes more accurate and fail-safe predictions. For cooling, the percentage for accurate and fail-safe predictions is between 97.6% and 100%. Under criterion 1, the percentage of accurate predictions is 47.5% for single-rate cooling and 66.7% for dual-rate cooling, while the fail-dangerous predictions are between 0% and 2.4%. This study demonstrates that IPMP Dynamic Prediction can be used by food processors and regulatory agencies as a tool to predict the growth of C. perfringens in uncured cooked meats and evaluate the safety of cooked or heat-treated uncured meat and poultry products exposed to cooling deviations or to develop customized cooling schedules. This study also demonstrates the need for more accurate data collection during cooling. Published 2016. This article is a U.S. Government work and is in the public domain in the USA.
NASA Technical Reports Server (NTRS)
Wilson, Robert W.; Richard, Paul H.; Brown, Kenneth D.
1945-01-01
Variable charge-air flow, cooling-air pressure drop, and fuel-air ration investigations were conducted to determine the cooling characteristics of a full-scale air-cooled single cylinder on a CUE setup. The data are compared with similar data that were available for the same model multicylinder engine tested in flight in a four-engine airplane. The cylinder-head cooling correlations were the same for both the single-cylinder and the flight engine. The cooling correlations for the barrels differed slightly in that the barrel of the single-cylinder engine runs cooler than the barrel of te flight engine for the same head temperatures and engine conditions.
Fallugia paradoxa (D. Don) Endl. ex Torr.: Apache-plume
Susan E. Meyer
2008-01-01
The genus Fallugia contains a single species - Apache-plume, F. paradoxa (D. Don) Endl. ex Torr. - found throughout the southwestern United States and northern Mexico. It occurs mostly on coarse soils on benches and especially along washes and canyons in both warm and cool desert shrub communities and up into the pinyon-juniper vegetation type. It is a sprawling, much-...
Progress in the Development of a Continuous Adiabatic Demagnetization Refrigerator
NASA Technical Reports Server (NTRS)
Shirron, Peter; Canavan, Edgar; DiPirro, Michael; Jackson, Michael; King, Todd; Tuttle, James; Krebs, Carolyn A. (Technical Monitor)
2002-01-01
We report on recent progress in the development of a continuous adiabatic demagnetization refrigerator (CADR). Continuous operation avoids the constraints of long hold times and short recycle times that lead to the generally large mass of single-shot ADRs, allowing us to achieve an order of magnitude larger cooling power per unit mass. Our current design goal is 10 micro W of cooling at 50 mK using a 6-10 K heat sink. The estimated mass is less than 10 kg, including magnetic shielding of each stage. The relatively high heat rejection capability allows it to operate with a mechanical cryocooler as part of a cryogen-free, low temperature cooling system. This has the advantages of long mission life and reduced complexity and cost. We have assembled a three-stage CADR and have demonstrated continuous cooling using a superfluid helium bath as the heat sink. The temperature stability is 8 micro K rms or better over the entire cycle, and the cooling power is 2.5 micro W at 60 mK rising to 10 micro W at 100 mK.
A Continuous Adiabatic Demagnetization Refrigerator for Far-IR/Sub-mm Astronomy
NASA Technical Reports Server (NTRS)
Shirron, Peter; Canavan, Edgar; DiPirro, Michael; Jackson, Michael; King, Todd; Tuttle, James
2004-01-01
We report on recent progress in the development of a continuous adiabatic demagnetization refrigerator (CADR). Continuous operation avoids the constraints of long hold times and short recycle times that lead to the generally large mass of single-shot ADRs, allowing us to achieve an order of magnitude larger cooling power per unit mass. Our current design goal is 10 microW of cooling at 50 mK using a 6-10 K heat sink. The estimated mass is less than 10 kg, including magnetic shielding of each stage. The relatively high heat rejection capability allows it to operate with a mechanical cryocooler as part of a cryogen-free, low temperature cooling system. This has the advantages of long mission life and reduced complexity and cost. We have assembled a three-stage CADR and have demonstrated continuous cooling using a superfluid helium bath as the heat sink. The temperature stability is 8 microK rms or better over the entire cycle, and the cooling power is 2.5 microW at 60 mK rising to 10 microW at 100 mK.
Development of a single-phase thermosiphon for cold collection and storage of radiative cooling
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhao, Dongliang; Martini, Christine Elizabeth; Jiang, Siyu
A single-phase thermosiphon is developed for cold collection and storage of radiative cooling. Compared to the conventional nocturnal radiative cooling systems that use an electric pump to drive the heat transfer fluid, the proposed single-phase thermosiphon uses the buoyancy force to drive heat transfer fluid. This solution does not require electricity, therefore improving the net gain of the radiative cooling system. A single-phase thermosiphon was built, which consists of a flat panel, a cold collection tank, a water return tube, and a water distribution tank. Considering that outdoor radiative cooling flux is constantly changing (i.e. uncontrollable), an indoor testing facilitymore » was developed to provide a controllable cooling flux (comparable to a radiative cooling flux of 100 W/m2) for the evaluation of thermosiphon performance. The testing apparatus is a chilled aluminum flat plate that has a controlled air gap separation relative to the flat panel surface of the thermosiphon to emulate radiative cooling. With an average of 105 W/m2 cooling flux, the 18 liters of water in the thermosiphon was cooled to an average temperature of 12.5 degrees C from an initial temperature of 22.2 degrees C in 2 h, with a cold collection efficiency of 96.8%. The results obtained have demonstrated the feasibility of using a single-phase thermosiphon for cold collection and storage of radiative cooling. Additionally, the effects of the thermosiphon operation conditions, such as tilt angle of the flat panel, initial water temperature, and cooling energy flux, on the performance have been experimentally investigated. Modular design of the single-phase thermosiphon gives flexibility for its scalability. A radiative cooling system with multiple thermosiphon modules is expected to play an important role in cooling buildings and power plant condensers.« less
NASA Astrophysics Data System (ADS)
Riesselman, C.; Dunbar, R. B.; Sjunneskog, C. M.; Mucciarone, D. A.; Winter, D.; Olney, M.; Tuzzi, E.; McKay, R. M.; Scherer, R. P.
2010-12-01
The marine sediment cores collected by the Antarctic Geological Drilling (ANDRILL) Program from sites beneath the McMurdo Ice Shelf (MIS; Core AND-1B) and in Southern McMurdo Sound (SMS; Core AND-2A) represent the most complete record to date of Neogene climate evolution proximal to the Antarctic continent. Diatom-rich lithologic units alternate with glacial sediments throughout the Pliocene and early Pleistocene of AND-1B; each diatom-rich unit within this oscillating record has distinctive geochemical and diatom assemblage characteristics and most are interpreted to preserve single interglacial intervals of 40-thousand-year glacial/interglacial cycles. Though the dramatic Pliocene glacial/interglacial oscillations recorded at the MIS site are absent in the shallower SMS record, AND-2A preserves a single diverse late Pliocene diatom assemblage, providing an additional constraint on Ross Sea Pliocene climate. Here, we focus on the reconstruction of sea surface conditions from four discrete AND-1B interglacial units deposited ~3.2, 3.0, 2.9, and 2.6 Ma. Diatom assemblages record the onset of Plio-Pleistocene cooling in the Ross Sea at 3.2 Ma, intensifying at 3.0 Ma, and suggest spring blooms in a surface ocean seasonally stratified by sea ice melt. Following the initial cooling, an increase in warm-water species at 2.9 and 2.6 Ma records a temporary late Pliocene reversal in the cooling trend. The Pliocene diatom-bearing interval in AND-2A is equivalent to the 2.6 Ma diatomite, providing further evidence for late Pliocene reversion to warmer open ocean conditions. Cooling resumes in the early Pleistocene, but sea-ice related diatoms, which dominate late Pleistocene and recent Antarctic sediments, are present only as minor components throughout the ANDRILL records. Sedimentary δ13C and δ15N in the AND-1B diatomite units provide additional insights into Pliocene evolution of sea ice, stratification, and primary productivity. For AND-1B diatomite units younger than 3.2 Ma, δ13C and δ15N vary in phase, the amplitude of δ13C fluctuations increases progressively up section, and peak interglacial δ15N trends toward more positive values, reflecting increasing variability in surface-water stratification within individual glacial minima. During the peaks of Late Pliocene glacial minima, negative δ13C values likely indicate enhanced wind mixing and summer polynya formation over AND-1B, while more positive values during the start and end of glacial minima indicate increased stratification due to sea ice melt or reduced wind stress. In sequence, these units offer a unique perspective on the changing character of the interglacial environment in the Ross Embayment spanning the transition from the mid-Pliocene climatic optimum into modern cold-polar conditions.
NASA Astrophysics Data System (ADS)
Chu, Zhaoxiang; Ji, Jianhu; Zhang, Xijun; Yan, Hongyuan; Dong, Haomin; Liu, Junjie
2016-12-01
Aiming at heat injuries occurring in the process of deep coal mining in China, a ZL400 mine-cooling unit employing semi-hermetic screw compressor with a cooling capacity of 400 kW is developed. This paper introduced its operating principle, structural characteristics and technical indexes. By using the self-built testing platform, some parameters for indication of its operation conditions were tested on the ground. The results show that the aforementioned cooling unit is stable in operation: cooling capacity of the unit was 420 kW underground-test conditions, while its COP (coefficient of performance) reached 3.4. To address the issue of heat injuries existing in No. 16305 U-shaped long-wall ventilation face of Jining No. 3 coal mine, a local air conditioning system was developed with ZL400 cooling unit as the system's core. The paper presented an analysis of characteristics of the air current flowing in the air-mixing and cooling mode of ZL400 cooling unit used in air intake way. Through i-d patterns we described the process of the airflow treatment, such as cooling, mixing and heating, etc. The cooling system decreased dry bulb temperature on working face by 3°C on average and 3.8°C at most, while lowered the web bulb temperature by 3.6°C on average and 4.8°C at most. At the same time, it reduced relative humidity by 5% on average and 8.6% at most. The field application of the ZL400 cooling unit had gain certain effects in air conditioning and provided support for the solution of mine heat injuries in China in terms of technology and equipment.
ERIC Educational Resources Information Center
Human Engineering Inst., Cleveland, OH.
THIS MODULE OF A 30-MODULE COURSE IS DESIGNED TO DEVELOP AN UNDERSTANDING OF THE FUNCTION AND MAINTENANCE OF THE DIESEL ENGINE COOLING SYSTEM AND THE PROCEDURES FOR TRANSMISSION INSTALLATION. TOPICS ARE (1) IMPORTANCE OF THE COOLING SYSTEM, (2) COOLING SYSTEM COMPONENTS, (3) EVALUATING COOLING SYSTEM FAILURES, (4) CARING FOR THE COOLING SYSTEM,…
Dynamically limiting energy consumed by cooling apparatus
Chainer, Timothy J.; David, Milnes P.; Iyengar, Madhusudan K.; Parida, Pritish R.; Schmidt, Roger R.; Schultz, Mark D.
2015-05-26
Cooling apparatuses and methods are provided which include one or more coolant-cooled structures associated with an electronics rack, a coolant loop coupled in fluid communication with one or more passages of the coolant-cooled structure(s), one or more heat exchange units coupled to facilitate heat transfer from coolant within the coolant loop, and N controllable components associated with the coolant loop or the heat exchange unit(s), wherein N.gtoreq.1. The N controllable components facilitate circulation of coolant through the coolant loop or transfer of heat from the coolant via the heat exchange unit(s). A controller is coupled to the N controllable components, and dynamically adjusts operation of the N controllable components, based on Z input parameters and one or more specified constraints, to provide a specified cooling to the coolant-cooled structure(s), while limiting energy consumed by the N controllable components, wherein Z.gtoreq.1.
Dynamically limiting energy consumed by cooling apparatus
Chainer, Timothy J.; David, Milnes P.; Iyengar, Madhusudan K.; Parida, Pritish R.; Schmidt, Roger R.; Schultz, Mark D.
2015-06-09
Cooling methods are provided which include providing: one or more coolant-cooled structures associated with an electronics rack, a coolant loop coupled in fluid communication with one or more passages of the coolant-cooled structure(s), one or more heat exchange units coupled to facilitate heat transfer from coolant within the coolant loop, and N controllable components associated with the coolant loop or the heat exchange unit(s), wherein N.gtoreq.1. The N controllable components facilitate circulation of coolant through the coolant loop or transfer of heat from the coolant via the heat exchange unit(s). A controller is also provided to dynamically adjust operation of the N controllable components, based on Z input parameters and one or more specified constraints, and provide a specified cooling to the coolant-cooled structure(s), while limiting energy consumed by the N controllable components, wherein Z.gtoreq.1.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Withers, C.; Cummings, J.; Nigusse, B.
A new generation of full variable-capacity, central, ducted air-conditioning (AC) and heat pump units has come on the market, and they promise to deliver increased cooling (and heating) efficiency. They are controlled differently than standard single-capacity (fixed-capacity) systems. Instead of cycling on at full capacity and then cycling off when the thermostat is satisfied, they can vary their capacity over a wide range (approximately 40% to 118% of nominal full capacity), thus staying “on” for up to twice as many hours per day compared to fixed-capacity systems of the same nominal capacity. The heating and cooling capacity is varied bymore » adjusting the indoor fan air flow rate, compressor, and refrigerant flow rate as well as the outdoor unit fan air flow rate. Note that two-stage AC or heat pump systems were not evaluated in this research effort. The term dwell is used to refer to the amount of time distributed air spends inside ductwork during space-conditioning cycles. Longer run times mean greater dwell time and therefore greater exposure to conductive gains and losses.« less
A Rapid Turnaround Cryogenic Detector Characterization System
NASA Technical Reports Server (NTRS)
Benford, Dominic j.; Dipirro, Michael J.; Forgione, Joshua B.; Jackson, Clifton E.; Jackson, Michael L.; Kogut, Al; Moseley, S. Harvey; Shirron, Peter J.
2004-01-01
Upcoming major NASA missions such as the Einstein Inflation Probe and the Single Aperture Far-Infrared Observatory require arrays of detectors with thousands of elements, operating at temperatures near l00 mK and sensitive to wavelengths from approx. 100 microns to approx. 3 mm. Such detectors represent a substantial enabling technology for these missions, and must be demonstrated soon in order for them to proceed. In order to make rapid progress on detector development, the cryogenic testing cycle must be made convenient and quick. We have developed a cryogenic detector characterization system capable of testing superconducting detector arrays in formats up to 8 x 32, read out by SQUID multiplexers. The system relies on the cooling of a two-stage adiabatic demagnetization refrigerator immersed in a liquid helium bath. This approach permits a detector to be cooled from 300K to 50 mK in about 4 hours, so that a test cycle begun in the morning will be over by the end of the day. Tine system is modular, with two identical immersible units, so that while one unit is cooling, the second can be reconfigured for the next battery of tests. We describe the design, construction, and performance of this cryogenic detector testing facility.
NASA Technical Reports Server (NTRS)
Erickson, Lisa R.; Ungar, Eugene K.
2012-01-01
Humans on a spacecraft require significant amounts of water for drinking, food, hydration, and hygiene. Maximizing the reuse of wastewater while minimizing the use of consumables is critical for long duration space exploration. One of the more promising consumable-free methods of reclaiming wastewater is the distillation/condensation process used in the Cascade Distillation Subsystem (CDS). The CDS heats wastewater to the point of vaporization then condenses and cools the resulting water vapor. The CDS wastewater flow requires heating for evaporation and the product water flow requires cooling for condensation. Performing the heating and cooling processes separately would require two separate units, each of which would demand large amounts of electrical power. Mass, volume, and power efficiencies can be obtained by heating the wastewater and cooling the condensate in a single heat pump unit. The present work describes and compares two competing heat pump methodologies that meet the needs of the CDS: 1) a series of mini compressor vapor compression cycles and 2) a thermoelectric heat exchanger. In the paper, the CDS system level requirements are outlined, the designs of the two heat pumps are described in detail, and the results of heat pump analysis and performance tests are provided. The mass, volume, and power requirement for each heat pump option is compared and the advantages and disadvantages of each system are listed.
Macro-channel cooled high power fiber coupled diode lasers exceeding 1.2kW of output power
NASA Astrophysics Data System (ADS)
Koenning, Tobias; Alegria, Kim; Wang, Zuolan; Segref, Armin; Stapleton, Dean; Faßbender, Wilhelm; Flament, Marco; Rotter, Karsten; Noeske, Axel; Biesenbach, Jens
2011-03-01
We report on a new series of fiber coupled diode laser modules exceeding 1.2kW of single wavelength optical power from a 400um / 0.2NA fiber. The units are constructed from passively cooled laser bars as opposed to other comparably powered, commercially available modules that use micro-channel heat-sinks. Micro-channel heat sinks require cooling water to meet demanding specifications and are therefore prone to failures due to contamination and increase the overall cost to operate and maintain the laser. Dilas' new series of high power fiber coupled diode lasers are designed to eliminate micro channel coolers and their associated failure mechanisms. Low-smile soldering processes were developed to maximize the brightness available from each diode laser bar. The diode laser brightness is optimally conserved using Dilas' recently developed propriety laser bar stacking geometry and optics. A total of 24 bars are coupled into a single fiber core using a polarization multiplexing scheme. The modular design permits further power scaling through wavelength multiplexing. Other customer critical features such as industrial grade fibers, pilot beams, fiber interlocks and power monitoring are standard features on these modules. The optical design and the beam parameter calculations will be presented to explain the inherit design trade offs. Results for single and dual wavelengths modules will be presented.
The effects of local forearm muscle cooling on motor unit properties.
Mallette, Matthew M; Green, Lara A; Gabriel, David A; Cheung, Stephen S
2018-02-01
Muscle cooling impairs maximal force. Using needle electromyography (EMG) to assess motor unit properties during muscle cooling, is limited and equivocal. Therefore, we aimed to determine the impact of local muscle cooling on motor unit firing properties using surface EMG decomposition. Twenty participants (12 M, 8 F) completed maximal, evoked, and trapezoidal contractions during thermoneutral and cold muscle conditions. Forearm muscle temperature was manipulated using 10-min neutral (~ 32 °C) or 20-min cold (~ 3 °C) water baths. Twitches and maximal voluntary contractions were performed prior to, and after, forearm immersion in neutral or cold water. Motor unit properties were assessed during trapezoidal contractions to 50% baseline force using surface EMG decomposition. Impaired contractile properties from muscle cooling were evident in the twitch amplitude, duration, and rate of force development indicating that the muscle was successfully cooled from the cold water bath (all d ≥ 0.5, P < 0.05). Surface EMG decomposition showed muscle cooling increased the number of motor units (d = 0.7, P = 0.01) and motor unit action potential (MUAP) duration (d = 0.6, P < 0.001), but decreased MUAP amplitude (d = 0.2, P = 0.012). Individually, neither motor unit firing rates (d = 0.1, P = 0.843) nor recruitment threshold (d = 0.1, P = 0.746) changed; however, the relationship between the recruitment threshold and motor unit firing rate was steeper (d = 1.0, P < 0.001) and had an increased y-intercept (d = 0.9, P = 0.007) with muscle cooling. Since muscle contractility is impaired with muscle cooling, these findings suggest a compensatory increase in the number of active motor units, and small but coupled changes in motor unit firing rates and recruitment threshold to produce the same force.
Design of a nuclear isotope heat source assembly for a spaceborne mini-Brayton power module.
NASA Technical Reports Server (NTRS)
Wein, D.; Gorland, S. H.
1973-01-01
Results of a study to develop a feasible design definition of a heat source assembly (HSA) for use in nominal 500-, 1200-, or 2000-W(e) mini-Brayton spacecraft power systems. The HSA is a modular design which is used either as a single unit to provide thermal energy to the 500-W(e) mini-Brayton power module or in parallel with one or two additional HSAs for the 1200- or 2000-W(e) power module systems. Principal components consist of a multihundred watt RTG isotope heat source, a heat source heat exchanger which transfers the thermal energy from the heat source to the mini-Brayton power conversion system, an auxiliary cooling system which provides requisite cooling during nonoperation of the power conversion module and an emergency cooling system which precludes accidental release of isotope fuel in the event of system failure.
NASA Astrophysics Data System (ADS)
Sakitani, Katsumi; Honda, Hiroshi
Experiments were performed to investigate feasibility of using organic materials as a PCM for a latent heat storage unit of a natural circulation cooling/latent heat storage system. This system was designed to cool a shelter accommodating telecommunication equipment located in subtropical deserts or similar regions without using a power source. Taking into account practical considerations and the results of various experiments regarding the thermodynamic properties, thermal degradation, and corrosiveness to metals, lauric acid and iron was selected for the PCM and the latent heat storage unit material, respectively. Cyclic heating and cooling of the latent heat storage unit undergoing solid-liquid phase change was repeated for more than 430 days. The results showed that the heating-cooling curve was almost unchanged between the early stage and the 1,870th cycle. It was concluded that the latent heat storage unit could be used safely for more than ten years as a component of the cooling system.
Development of a thermoelectric one-man cooler for use by NASA astronauts
DOE Office of Scientific and Technical Information (OSTI.GOV)
Heenan, P.; Mathiprakasam, B.; DeMott, D.
This paper presents the development of a one-man thermoelectric (TE) cooling unit designed for use by NASA astronauts while they are wearing a protective suit during the launch and reentry phases of space shuttle missions. The unit was designed to provide a low-cooling level of 340 Btu/hour in a 75{degree}F environment and a high-cooling level of 480 Btu/hour in a 95{degree}F environment. The unit has an envelope 8 inches wide by 11 inches high by 4.5 inches deep. The TE unit was designed to optimize space and power consumption while providing adequate cooling. The operation of the TE cooling unitmore » requires {similar_to}1.2 amps of 28 VDC power in the low power mode and {similar_to}3.0 amps of 28 VDC power in the high power mode. Two of these units have flown on several shuttle missions this year and are scheduled for continued use on future missions. The response to the TE unit`s performance has been very positive from the shuttle crew. Additional units are being fabricated to keep the shuttle crew members cooled while final development is under way. {copyright} {ital 1995} {ital American} {ital Institute} {ital of} {ital Physics}.« less
A Continuous Adiabatic Demagnetization Refrigerator for Use with Mechanical Coolers
NASA Technical Reports Server (NTRS)
Shirron, P.; Abbondante, N.; Canavan, E.; DiPirro, M.; Grabowski, M.; Hirsch, M.; Jackson, M.; Tuttle, J.
2000-01-01
We have begun developing an adiabatic demagnetization refrigerator (ADR) which can produce continuous cooling at temperatures of 50 mK or lower, with high cooling power (goal of 10 PW). The design uses multiple stages to cascade heat from a continuously-cooled stage up to a heat sink. The serial arrangement makes it possible to add stages to extend the operating range to lower temperature, or to raise the heat rejection temperature. Compared to conventional single-shot ADRS, this system achieves higher cooling power per unit mass and is able to reject its heat at a more uniform rate. For operation with a mechanical cryocooler, this latter feature stabilizes the heat sink temperature and allows both the ADR and cryocooler to operate more efficiently. The ADR is being designed to operate with a heat sink as warm as 10-12 K to make it compatible with a wide variety of mechanical coolers as part of a versatile, cryogen-free low temperature cooling system. A two-stage system has been constructed and a proof-of-principle demonstration was conducted at 100 mK. Details of the design and test results, as well as the direction of future work, are discussed.
Paleointensity results for 0 and 4 ka from Hawaiian lava flows: a new approach to sampling
NASA Astrophysics Data System (ADS)
Cromwell, G.; Tauxe, L.; Staudigel, H.; Ron, H.; Trusdell, F.
2012-04-01
Paleointensity data are typically generated from core samples drilled out of the massive parts of lava flows. During Thellier-Thellier type experiments, these massive samples suffer from very low success rates (~20%), as shown by failure to meet statistical criteria. Low success generally occurs for two reasons: 1) alteration of the sample during the heating process, and 2) multi-domain behavior of massive material. Moreover, recent studies of historical lava flows show that massive samples may not accurately reflect the intensity of the magnetic field even when they are successful (Valet et al., 2010). Alternatively, submarine basaltic glasses (SBG) produce high success rates (~80%) for Thellier-Thellier type experiments, likely due to near instantaneous cooling rates which produce single-domain magnetic grains. In addition, SBG have been proven to produce accurate records of the magnetic field (e.g., Pick and Tauxe, 1993). In this study we investigate the success of paleointensity experiments on subaerial quenched basalts from Hawaii in the quest for single domain, rapidly cooled subaerial analogs to SBG. We also examine the effects of grain size and cooling rate on the accuracy of paleointensity results. During March 2011, we collected samples from 31 dated lava flows (0-3800 BP), including the historical 1950 C.E. and 2010 C.E. flows. Each lava flow was additionally subsampled when unique cooling structures within the unit could be identified. Single-domain, rapidly quenched glasses from the 1950 and 2010 flows are ideally behaved, i.e. straight Arai plots, and accurately record the expected geomagnetic field strength. However, slower cooled specimens from the same flows produce sagged Arai plots and consistently underestimate expected geomagnetic field intensity. Results from ideally behaved glasses over the last 4 ka indicate periods of rapid field change in Hawaii and a possible high intensity field spike around 2.7 ka. We will present new results from our comprehensive data set of Hawaii paleointensity on about the last 4 ka.
Cooling in the single-photon strong-coupling regime of cavity optomechanics
NASA Astrophysics Data System (ADS)
Nunnenkamp, A.; Børkje, K.; Girvin, S. M.
2012-05-01
In this Rapid Communication we discuss how red-sideband cooling is modified in the single-photon strong-coupling regime of cavity optomechanics where the radiation pressure of a single photon displaces the mechanical oscillator by more than its zero-point uncertainty. Using Fermi's golden rule we calculate the transition rates induced by the optical drive without linearizing the optomechanical interaction. In the resolved-sideband limit we find multiple-phonon cooling resonances for strong single-photon coupling that lead to nonthermal steady states including the possibility of phonon antibunching. Our study generalizes the standard linear cooling theory.
NASA Astrophysics Data System (ADS)
Haug, M.; Haussmann, F.; Kellner, S.; Kern, L.; Eisenhauer, F.; Lizon, J.-L.; Dietrich, M.; Thummes, G.
2014-07-01
GRAVITY is a second generation VLTI instrument for high-precision narrow-angle astrometry and phase-referenced interferometric imaging in the astronomical K-band. The cryostat of the beam combiner instrument provides the required temperatures for the various subunits ranging from 40K to 290K with a milli-Kelvin temperature stability for some selected units. The bath cryostat is cooled with liquid nitrogen and makes use of the exhaust gas to cool the main optical bench to an intermediate temperature of 240K. The fringe tracking detector will be cooled separately by a single-stage pulse tube cooler to a temperature of 40K. The pulse tube cooler is optimized for minimum vibrations. In particular its warm side is connected to the 80K reservoir of the LN2 cryostat to minimize the required input power. All temperature levels are actively stabilized by electric heaters. The cold bench is supported separately from the vacuum vessel and the liquid nitrogen reservoir to minimize the transfer of acoustic noise onto the instrument.
21 CFR 878.4350 - Cryosurgical unit and accessories.
Code of Federal Regulations, 2010 CFR
2010-04-01
... and accessories. (a) Identification—(1) Cryosurgical unit with a liquid nitrogen cooled cryoprobe and accessories. A cryosurgical unit with a liquid nitrogen cooled cryoprobe and accessories is a device intended...
Heat recovery system series arrangements
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kauffman, Justin P.; Welch, Andrew M.; Dawson, Gregory R.
The present disclosure is directed to heat recovery systems that employ two or more organic Rankine cycle (ORC) units disposed in series. According to certain embodiments, each ORC unit includes an evaporator that heats an organic working fluid, a turbine generator set that expands the working fluid to generate electricity, a condenser that cools the working fluid, and a pump that returns the working fluid to the evaporator. The heating fluid is directed through each evaporator to heat the working fluid circulating within each ORC unit, and the cooling fluid is directed through each condenser to cool the working fluidmore » circulating within each ORC unit. The heating fluid and the cooling fluid flow through the ORC units in series in the same or opposite directions.« less
Single-molecule electronics: Cooling individual vibrational modes by the tunneling current.
Lykkebo, Jacob; Romano, Giuseppe; Gagliardi, Alessio; Pecchia, Alessandro; Solomon, Gemma C
2016-03-21
Electronic devices composed of single molecules constitute the ultimate limit in the continued downscaling of electronic components. A key challenge for single-molecule electronics is to control the temperature of these junctions. Controlling heating and cooling effects in individual vibrational modes can, in principle, be utilized to increase stability of single-molecule junctions under bias, to pump energy into particular vibrational modes to perform current-induced reactions, or to increase the resolution in inelastic electron tunneling spectroscopy by controlling the life-times of phonons in a molecule by suppressing absorption and external dissipation processes. Under bias the current and the molecule exchange energy, which typically results in heating of the molecule. However, the opposite process is also possible, where energy is extracted from the molecule by the tunneling current. Designing a molecular "heat sink" where a particular vibrational mode funnels heat out of the molecule and into the leads would be very desirable. It is even possible to imagine how the vibrational energy of the other vibrational modes could be funneled into the "cooling mode," given the right molecular design. Previous efforts to understand heating and cooling mechanisms in single molecule junctions have primarily been concerned with small models, where it is unclear which molecular systems they correspond to. In this paper, our focus is on suppressing heating and obtaining current-induced cooling in certain vibrational modes. Strategies for cooling vibrational modes in single-molecule junctions are presented, together with atomistic calculations based on those strategies. Cooling and reduced heating are observed for two different cooling schemes in calculations of atomistic single-molecule junctions.
Using Field-Metered Data to Quantify Annual Energy Use of Portable Air Conditioners
DOE Office of Scientific and Technical Information (OSTI.GOV)
Burke, Thomas; Willem, Henry; Ni, Chun Chun
2014-12-01
As many regions of the United States experience rising temperatures, consumers have come to rely increasingly on cooling appliances (including portable air conditioners) to provide a comfortable indoor temperature. Home occupants sometimes use a portable air conditioner (PAC) to maintain a desired indoor temperature in a single room or enclosed space. Although PACs in residential use are few compared to centrally installed and room air conditioning (AC) units, the past few years have witnessed an increase of PACs use throughout the United States. There is, however, little information and few research projects focused on the energy consumption and performance ofmore » PACs, particularly studies that collect information from field applications of PACs. The operation and energy consumption of PACs may differ among geographic locations and households, because of variations in cooling load, frequency, duration of use, and other user-selected settings. In addition, the performance of building envelope (thermal mass and air leakage) as well as inter-zonal mixing within the building would substantially influence the ability to control and maintain desirable indoor thermal conditions. Lawrence Berkeley National Laboratory (LBNL) conducted an initial field-metering study aimed at increasing the knowledge and data related to PAC operation and energy consumption in the United States.« less
NASA Astrophysics Data System (ADS)
Miara, A.; Vorosmarty, C. J.; Stewart, R.; Wollheim, W. M.; Rosenzweig, B.
2013-12-01
Major strategic issues facing the global thermoelectric sector include environmental regulation, climate change and increasing electricity demand. We have addressed such issues by modeling thermoelectric generation in the Northeastern United States that is reliant on cooling under five sensitivity tests to evaluate losses/gains in power production, thermal pollution and suitable aquatic habitat, comparing the contemporary baseline (2000-2010) with potential future states. Integral to the analysis, we developed a methodology to quantify river water availability for cooling, which we define as an ecosystem service. Projected climate conditions reduce river water available for efficient power plant operations and the river's capacity to absorb waste heat, causing a loss of regional thermoelectric generation (RTG) (2.5%) in some summers that, compared to the contemporary baseline, is equal to the summertime electricity consumption of 1.3 million Northeastern US homes. Vulnerabilities to warm temperatures and thermal pollution can be alleviated through the use of more efficient natural gas (NG) power plants that have a reduced reliance on cooling water. Conversion of once-through (OT) to cooling tower (CT) systems and the Clean Water Act (CWA) temperature limit regulation, both of which reduce efficiencies at the single plant level, show potential to yield beneficial increases in RTG. This is achieved by obviating the need for large volumes of river water, thereby reducing plant-to-plant interferences through lowering the impact of upstream thermal pollution and preserving a minimum standard of cooling water. The results and methodology framework presented here, which can be extrapolated to other regional assessments with contrasting climates and thermoelectric profiles, can identify opportunities and support decision-making to achieve more efficient energy systems and riverine ecosystem protection.
NASA Astrophysics Data System (ADS)
Miara, Ariel; Vörösmarty, Charles J.; Stewart, Robert J.; Wollheim, Wilfred M.; Rosenzweig, Bernice
2013-06-01
Major strategic issues facing the global thermoelectric sector include environmental regulation, climate change and increasing electricity demand. We have addressed such issues by modeling thermoelectric generation in the Northeastern United States that is reliant on cooling under five sensitivity tests to evaluate losses/gains in power production, thermal pollution and suitable aquatic habitat, comparing the contemporary baseline (2000-2010) with potential future states. Integral to the analysis, we developed a methodology to quantify river water availability for cooling, which we define as an ecosystem service. Projected climate conditions reduce river water available for efficient power plant operations and the river’s capacity to absorb waste heat, causing a loss of regional thermoelectric generation (RTG) (2.5%) in some summers that, compared to the contemporary baseline, is equal to the summertime electricity consumption of 1.3 million Northeastern US homes. Vulnerabilities to warm temperatures and thermal pollution can be alleviated through the use of more efficient natural gas (NG) power plants that have a reduced reliance on cooling water. Conversion of once-through (OT) to cooling tower (CT) systems and the Clean Water Act (CWA) temperature limit regulation, both of which reduce efficiencies at the single plant level, show potential to yield beneficial increases in RTG. This is achieved by obviating the need for large volumes of river water, thereby reducing plant-to-plant interferences through lowering the impact of upstream thermal pollution and preserving a minimum standard of cooling water. The results and methodology framework presented here, which can be extrapolated to other regional assessments with contrasting climates and thermoelectric profiles, can identify opportunities and support decision-making to achieve more efficient energy systems and riverine ecosystem protection.
The effect of pre-storage cooling on 2,3-DPG levels in red cells stored in SAG-M.
Llohn, Abid Hussain; Vetlesen, Annette; Fagerhol, Magne Kristoffer; Kjeldsen-Kragh, Jens
2005-10-01
The concentration of red cell 2,3-DPG (2,3-diphosphoglycerate) rapidly decreases during storage. A favourable effect on red cell 2,3-DPG has been demonstrated by rapid cooling of whole blood prior to storage. In our study we have investigated how different methods of cooling whole blood immediately after donation effect 2,3-DPG levels during storage. Thirty-six whole blood units (in 6 groups) of 450 ml were collected in 63 ml CPD. SAG-M was used as preservative solution for red cell concentrates (RCC). The units in one group were cooled down at ambient temperature, while units in the other groups were cooled down rapidly by different ways immediately after bleeding. Samples from the whole blood units were collected at various days during storage for 2,3-DPG measurements. The decline in 2,3-DPG during the first two weeks of storage was significantly slower in the groups which were cooled down rapidly to 17-18 degrees C within 1h after bleeding (all p
NASA Astrophysics Data System (ADS)
Wojciechowski, Jerzy
2013-03-01
The paper describes the design and results of operating measurements of the GMC-1000 and GMC- 2000 Mine Cooling Units. The first part describes the design of the cooling unit and its key components: the chiller, evaporator, condenser, oil cooler, evaporative water cooler and gallery air cooler. The possibilities of use in central air conditioning systems of underground mines are described. The second part discusses the results of the workstation and operating measurements and determines the coefficients for evaluating the performance of the mine cooling unit.
Cooling arrangement for a tapered turbine blade
Liang, George
2010-07-27
A cooling arrangement (11) for a highly tapered gas turbine blade (10). The cooling arrangement (11) includes a pair of parallel triple-pass serpentine cooling circuits (80,82) formed in an inner radial portion (50) of the blade, and a respective pair of single radial channel cooling circuits (84,86) formed in an outer radial portion (52) of the blade (10), with each single radial channel receiving the cooling fluid discharged from a respective one of the triple-pass serpentine cooling circuit. The cooling arrangement advantageously provides a higher degree of cooling to the most highly stressed radially inner portion of the blade, while providing a lower degree of cooling to the less highly stressed radially outer portion of the blade. The cooling arrangement can be implemented with known casting techniques, thereby facilitating its use on highly tapered, highly twisted Row 4 industrial gas turbine blades that could not be cooled with prior art cooling arrangements.
Cavity cooling a single charged levitated nanosphere.
Millen, J; Fonseca, P Z G; Mavrogordatos, T; Monteiro, T S; Barker, P F
2015-03-27
Optomechanical cavity cooling of levitated objects offers the possibility for laboratory investigation of the macroscopic quantum behavior of systems that are largely decoupled from their environment. However, experimental progress has been hindered by particle loss mechanisms, which have prevented levitation and cavity cooling in a vacuum. We overcome this problem with a new type of hybrid electro-optical trap formed from a Paul trap within a single-mode optical cavity. We demonstrate a factor of 100 cavity cooling of 400 nm diameter silica spheres trapped in vacuum. This paves the way for ground-state cooling in a smaller, higher finesse cavity, as we show that a novel feature of the hybrid trap is that the optomechanical cooling becomes actively driven by the Paul trap, even for singly charged nanospheres.
Cavity Cooling a Single Charged Levitated Nanosphere
NASA Astrophysics Data System (ADS)
Millen, J.; Fonseca, P. Z. G.; Mavrogordatos, T.; Monteiro, T. S.; Barker, P. F.
2015-03-01
Optomechanical cavity cooling of levitated objects offers the possibility for laboratory investigation of the macroscopic quantum behavior of systems that are largely decoupled from their environment. However, experimental progress has been hindered by particle loss mechanisms, which have prevented levitation and cavity cooling in a vacuum. We overcome this problem with a new type of hybrid electro-optical trap formed from a Paul trap within a single-mode optical cavity. We demonstrate a factor of 100 cavity cooling of 400 nm diameter silica spheres trapped in vacuum. This paves the way for ground-state cooling in a smaller, higher finesse cavity, as we show that a novel feature of the hybrid trap is that the optomechanical cooling becomes actively driven by the Paul trap, even for singly charged nanospheres.
Optimal load scheduling in commercial and residential microgrids
NASA Astrophysics Data System (ADS)
Ganji Tanha, Mohammad Mahdi
Residential and commercial electricity customers use more than two third of the total energy consumed in the United States, representing a significant resource of demand response. Price-based demand response, which is in response to changes in electricity prices, represents the adjustments in load through optimal load scheduling (OLS). In this study, an efficient model for OLS is developed for residential and commercial microgrids which include aggregated loads in single-units and communal loads. Single unit loads which include fixed, adjustable and shiftable loads are controllable by the unit occupants. Communal loads which include pool pumps, elevators and central heating/cooling systems are shared among the units. In order to optimally schedule residential and commercial loads, a community-based optimal load scheduling (CBOLS) is proposed in this thesis. The CBOLS schedule considers hourly market prices, occupants' comfort level, and microgrid operation constraints. The CBOLS' objective in residential and commercial microgrids is the constrained minimization of the total cost of supplying the aggregator load, defined as the microgrid load minus the microgrid generation. This problem is represented by a large-scale mixed-integer optimization for supplying single-unit and communal loads. The Lagrangian relaxation methodology is used to relax the linking communal load constraint and decompose the independent single-unit functions into subproblems which can be solved in parallel. The optimal solution is acceptable if the aggregator load limit and the duality gap are within the bounds. If any of the proposed criteria is not satisfied, the Lagrangian multiplier will be updated and a new optimal load schedule will be regenerated until both constraints are satisfied. The proposed method is applied to several case studies and the results are presented for the Galvin Center load on the 16th floor of the IIT Tower in Chicago.
A molecular dynamics study of cooling rate during solidification of metal nanoparticles
NASA Astrophysics Data System (ADS)
Shibuta, Yasushi; Suzuki, Toshio
2011-01-01
The effect of the cooling rate on the solidification behavior of metal nanoparticles is investigated by molecular dynamics simulation. The structure of molybdenum nanoparticles varies with the cooling rate. That is, single-crystalline, polycrystalline then glassy nanoparticles are obtained as the cooling rate is increased from 2.0 × 10 10 to 1.0 × 10 13 K/s. The solidification point decreases with increasing cooling rate then drops rapidly at a cooling rate on the order of 10 12 K/s. These results are summarized in a continuous cooling transformation (CCT) diagram, in which regions corresponding the liquid, single-crystalline, polycrystalline and glassy structures appear.
Thermoelectric-enhanced, liquid-based cooling of a multi-component electronic system
Chainer, Timothy J; Graybill, David P; Iyengar, Madhusudan K; Kamath, Vinod; Kochuparambil, Bejoy J; Schmidt, Roger R; Steinke, Mark E
2015-11-10
Methods are provided for facilitating cooling of an electronic component. The methods include providing: a liquid-cooled structure, a thermal conduction path coupling the electronic component and the liquid-cooled structure, a coolant loop in fluid communication with a coolant-carrying channel of the liquid-cooled structure, and an outdoor-air-cooled heat exchange unit coupled to facilitate heat transfer from the liquid-cooled structure via, at least in part, the coolant loop. The thermoelectric array facilitates transfer of heat from the electronic component to the liquid-cooled structure, and the heat exchange unit cools coolant passing through the coolant loop by dissipating heat from the coolant to outdoor ambient air. In one implementation, temperature of coolant entering the liquid-cooled structure is greater than temperature of the outdoor ambient air to which heat is dissipated.
Thermoelectric-enhanced, liquid-based cooling of a multi-component electronic system
Chainer, Timothy J; Graybill, David P; Iyengar, Madhusudan K; Kamath, Vinod; Kochuparambil, Bejoy J; Schmidt, Roger R; Steinke, Mark E
2015-05-12
Apparatus and method are provided for facilitating cooling of an electronic component. The apparatus includes a liquid-cooled structure, a thermal conduction path coupling the electronic component and the liquid-cooled structure, a coolant loop in fluid communication with a coolant-carrying channel of the liquid-cooled structure, and an outdoor-air-cooled heat exchange unit coupled to facilitate heat transfer from the liquid-cooled structure via, at least in part, the coolant loop. The thermoelectric array facilitates transfer of heat from the electronic component to the liquid-cooled structure, and the heat exchange unit cools coolant passing through the coolant loop by dissipating heat from the coolant to outdoor ambient air. In one implementation, temperature of coolant entering the liquid-cooled structure is greater than temperature of the outdoor ambient air to which heat is dissipated.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Berlin, V. V., E-mail: vberlin@rinet.ru; Murav’ev, O. A., E-mail: muraviov1954@mail.ru; Golubev, A. V., E-mail: electronik@inbox.ru
Aspects of the startup of pumping units in the cooling and process water supply systems for thermal and nuclear power plants with cooling towers, the startup stages, and the limits imposed on the extreme parameters during transients are discussed.
Performance analysis of phase-change material storage unit for both heating and cooling of buildings
NASA Astrophysics Data System (ADS)
Waqas, Adeel; Ali, Majid; Ud Din, Zia
2017-04-01
Utilisation of solar energy and the night ambient (cool) temperatures are the passive ways of heating and cooling of buildings. Intermittent and time-dependent nature of these sources makes thermal energy storage vital for efficient and continuous operation of these heating and cooling techniques. Latent heat thermal energy storage by phase-change materials (PCMs) is preferred over other storage techniques due to its high-energy storage density and isothermal storage process. The current study was aimed to evaluate the performance of the air-based PCM storage unit utilising solar energy and cool ambient night temperatures for comfort heating and cooling of a building in dry-cold and dry-hot climates. The performance of the studied PCM storage unit was maximised when the melting point of the PCM was ∼29°C in summer and 21°C during winter season. The appropriate melting point was ∼27.5°C for all-the-year-round performance. At lower melting points than 27.5°C, declination in the cooling capacity of the storage unit was more profound as compared to the improvement in the heating capacity. Also, it was concluded that the melting point of the PCM that provided maximum cooling during summer season could be used for winter heating also but not vice versa.
Busch, H-J; Eichwede, F; Födisch, M; Taccone, F S; Wöbker, G; Schwab, T; Hopf, H-B; Tonner, P; Hachimi-Idrissi, S; Martens, P; Fritz, H; Bode, Ch; Vincent, J-L; Inderbitzen, B; Barbut, D; Sterz, F; Janata, A
2010-08-01
Mild therapeutic hypothermia improves survival and neurologic recovery in primary comatose survivors of cardiac arrest. Cooling effectivity, safety and feasibility of nasopharyngeal cooling with the RhinoChill device (BeneChill Inc., San Diego, USA) were determined for induction of therapeutic hypothermia. Eleven emergency departments and intensive care units participated in this multi-centre, single-arm descriptive study. Eighty-four patients after successful resuscitation from cardiac arrest were cooled with nasopharyngeal delivery of an evaporative coolant for 1h. Subsequently, temperature was controlled with systemic cooling at 33 degrees C. Cooling rates, adverse events and neurologic outcome at hospital discharge using cerebral performance categories (CPC; CPC 1=normal to CPC 5=dead) were documented. Temperatures are presented as median and the range from the first to the third quartile. Nasopharyngeal cooling for 1h reduced tympanic temperature by median 2.3 (1.6; 3.0) degrees C, core temperature by 1.1 (0.7; 1.5) degrees C. Nasal discoloration occurred during the procedure in 10 (12%) patients, resolved in 9, and was persistent in 1 (1%). Epistaxis was observed in 2 (2%) patients. Periorbital gas emphysema occurred in 1 (1%) patient and resolved spontaneously. Thirty-four of 84 patients (40%) patients survived, 26/34 with favorable neurological outcome (CPC of 1-2) at discharge. Nasopharyngeal evaporative cooling used for 1h in primary cardiac arrest survivors is feasible and safe at flow rates of 40-50L/min in a hospital setting. Copyright 2010 Elsevier Ireland Ltd. All rights reserved.
Modeling Single-Phase and Boiling Liquid Jet Impingement Cooling in Power Electronics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Narumanchi, S. V. J.; Hassani, V.; Bharathan, D.
2005-12-01
Jet impingement has been an attractive cooling option in a number of industries over the past few decades. Over the past 15 years, jet impingement has been explored as a cooling option in microelectronics. Recently, interest has been expressed by the automotive industry in exploring jet impingement for cooling power electronics components. This technical report explores, from a modeling perspective, both single-phase and boiling jet impingement cooling in power electronics, primarily from a heat transfer viewpoint. The discussion is from the viewpoint of the cooling of IGBTs (insulated-gate bipolar transistors), which are found in hybrid automobile inverters.
Annular feed air breathing fuel cell stack
Wilson, Mahlon S.
1996-01-01
A stack of polymer electrolyte fuel cells is formed from a plurality of unit cells where each unit cell includes fuel cell components defining a periphery and distributed along a common axis, where the fuel cell components include a polymer electrolyte membrane, an anode and a cathode contacting opposite sides of the membrane, and fuel and oxygen flow fields contacting the anode and the cathode, respectively, wherein the components define an annular region therethrough along the axis. A fuel distribution manifold within the annular region is connected to deliver fuel to the fuel flow field in each of the unit cells. In a particular embodiment, a single bolt through the annular region clamps the unit cells together. In another embodiment, separator plates between individual unit cells have an extended radial dimension to function as cooling fins for maintaining the operating temperature of the fuel cell stack.
Challenges and Opportunities in Gen3 Embedded Cooling with High-Quality Microgap Flow
NASA Technical Reports Server (NTRS)
Bar-Cohen, Avram; Robinson, Franklin L.; Deisenroth, David C.
2018-01-01
Gen3, Embedded Cooling, promises to revolutionize thermal management of advanced microelectronic systems by eliminating the sequential conductive and interfacial thermal resistances which dominate the present 'remote cooling' paradigm. Single-phase interchip microfluidic flow with high thermal conductivity chips and substrates has been used successfully to cool single transistors dissipating more than 40kW/sq cm, but efficient heat removal from transistor arrays, larger chips, and chip stacks operating at these prodigious heat fluxes would require the use of high vapor fraction (quality), two-phase cooling in intra- and inter-chip microgap channels. The motivation, as well as the challenges and opportunities associated with evaporative embedded cooling in realistic form factors, is the focus of this paper. The paper will begin with a brief review of the history of thermal packaging, reflecting the 70-year 'inward migration' of cooling technology from the computer-room, to the rack, and then to the single chip and multichip module with 'remote' or attached air- and liquid-cooled coldplates. Discussion of the limitations of this approach and recent results from single-phase embedded cooling will follow. This will set the stage for discussion of the development challenges associated with application of this Gen3 thermal management paradigm to commercial semiconductor hardware, including dealing with the effects of channel length, orientation, and manifold-driven centrifugal acceleration on the governing behavior.
Akiyama, Tasuku; Carstens, Mirela Iodi; Carstens, E
2009-10-01
Recent studies have suggested the existence of separate transduction mechanisms and sensory pathways for histamine and nonhistaminergic types of itch. We studied whether histamine and an agonist of the protease-activated receptor (PAR)-2, associated with nonhistaminergic itch, excite murine dorsal horn neurons. Single units were recorded in superficial lumbar dorsal horn of adult ICR mice anesthetized with pentobarbital. Unit activity was searched using a small intradermal hindpaw injection of histamine or the PAR-2 agonist SLIGRL-NH2. Isolated units were subsequently challenged with intradermal histamine followed by SLIGRL-NH2 (each 50 microg/1 microl) or reverse order, followed by mechanical, thermal, and algogenic stimuli. Forty-three units were classified as wide dynamic range (62%), nociceptive specific (22%), or mechano insensitive (16%). Twenty units gave prolonged (mean, 10 min) discharges to intradermal injection of histamine; 76% responded to subsequent SLIGRL-NH2, often more briefly. Units additionally responded to noxious heat (63%), cooling (43%), topical mustard oil (53%), and intradermal capsaicin (67%). Twenty-two other units gave prolonged (mean, 5 min) responses to initial intradermal injection of SLIGRL-NH2; 85% responded to subsequent intradermal histamine. They also responded to noxious heat (75%), mustard oil (93%), capsaicin (63%), and one to cooling. Most superficial dorsal horn neurons were excited by both histamine and the PAR-2 agonist, suggesting overlapping pathways for histamine- and non-histamine-mediated itch. Because the large majority of pruritogen-responsive neurons also responded to noxious stimuli, itch may be signaled at least partly by a population code.
NASA Technical Reports Server (NTRS)
Etter,David; Rector, Tony; Boyle, robert; Zande, Chris Vande
2012-01-01
The EMU (Extravehicular Mobility Unit) contains a semi-closed-loop re-circulating water circuit (Transport Loop) to absorb heat into a LCVG (Liquid Coolant and Ventilation Garment) worn by the astronaut. A second, single-pass water circuit (Feed-water Loop) provides water to a cooling device (Sublimator) containing porous plates, and that water sublimates through the porous plates to space vacuum. The cooling effect from the sublimation of this water translates to a cooling of the LCVG water that circulates through the Sublimator. The quality of the EMU Transport Loop water is maintained through the use of a water processing kit (ALCLR - Airlock Cooling Loop Remediation) that is used to periodically clean and disinfect the water circuit. Opportunities to reduce crew time associated with ALCLR operations include a detailed review of the historical water quality data for evidence to support an extension to the implementation cycle. Furthermore, an EMU returned after 2-years of use on the ISS (International Space Station) is being used as a test bed to evaluate the results of extended and repeated ALCLR implementation cycles. Finally, design, use and on-orbit location enhancements to the ALCLR kit components are being considered to allow the implementation cycle to occur in parallel with other EMU maintenance and check-out activities, and to extend the life of the ALCLR kit components. These efforts are undertaken to reduce the crew-time and logistics burdens for the EMU, while ensuring the long-term health of the EMU water circuits for a post- Shuttle 6-year service life.
NASA Technical Reports Server (NTRS)
Steele, John W.; Etter, David; Rector, Tony; Boyle, Robert; Vandezande, Christopher
2013-01-01
The EMU (Extravehicular Mobility Unit) contains a semi-closed-loop re-circulating water circuit (Transport Loop) to absorb heat into a LCVG (Liquid Coolant and Ventilation Garment) worn by the astronaut. A second, single-pass water circuit (Feed-water Loop) provides water to a cooling device (Sublimator) containing porous plates, and that water sublimates through the porous plates to space vacuum. The cooling effect from the sublimation of this water translates to a cooling of the LCVG water that circulates through the Sublimator. The quality of the EMU Transport Loop water is maintained through the use of a water processing kit (ALCLR Airlock Cooling Loop Remediation) that is used to periodically clean and disinfect the water circuit. Opportunities to reduce crew time associated with on-orbit ALCLR operations include a detailed review of the historical water quality data for evidence to support an extension to the implementation cycle. Furthermore, an EMU returned after 2-years of use on the ISS (International Space Station) is being used as a test bed to evaluate the results of extended and repeated ALCLR implementation cycles. Finally, design, use and on-orbit location enhancements to the ALCLR kit components are being considered to allow the implementation cycle to occur in parallel with other EMU maintenance and check-out activities, and to extend the life of the ALCLR kit components. These efforts are undertaken to reduce the crew-time and logistics burdens for the EMU, while ensuring the long-term health of the EMU water circuits for a post-Shuttle 6-year service life.
Paleointensity results for 0 and 3 ka from Hawaiian lava flows: a new approach to sampling
NASA Astrophysics Data System (ADS)
Cromwell, G.; Tauxe, L.; Staudigel, H.; Ron, H.; Trusdell, F.
2011-12-01
Paleointensity data are typically generated from core samples drilled out of the massive parts of lava flows. During Thellier-Thellier type experiments, these massive samples suffer from very low success rates (~20%), as shown by failure to meet statistical criteria. Low success generally occurs for two reasons: 1) alteration of the sample during the heating process, and 2) multi-domain behavior of massive material. Moreover, recent studies of historical lava flows show that massive samples may not accurately reflect the intensity of the magnetic field even when they are successful (Valet et al., 2010). Alternatively, submarine basaltic glasses (SBG) produce high success rates (~80%) for Thellier-Thellier type experiments, likely due to near instantaneous cooling rates which produce single-domain magnetic grains. In addition, SBG have been proven to produce accurate records of the magnetic field (e.g., Pick and Tauxe, 1993). In this study we investigate the success of paleointensity experiments on subaerial quenched basalts from Hawaii in the quest for single domain, rapidly cooled subaerial analogs to SBG. We also examine the effects of grain size and cooling rate on the accuracy of paleointensity results. During March 2011, we collected samples from 31 dated lava flows (0-3360 BP), including the [historical] 1950 C.E. and 2010 C.E. flows. Each lava flow was additionally subsampled when unique cooling structures within the unit could be identified. Results from the 1950 and 2010 glasses accurately record the expected geomagnetic field strength. We will present results of a comprehensive data set of Hawaiian paleointensity focused on about the last 3 ka.
Evaluation of Aqua-Ammonia Chiller Technologies and Field Site Installation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zaltash, Abdolreza
2007-09-01
The Naval Facilities Engineering Service Center (NFESC) has sponsored Oak Ridge National Laboratory (ORNL) to review, select, and evaluate advanced, gas-fired, 5-ton, aqua-ammonia, chiller technologies. The selection criteria was that units have COP values of 0.67 or better at Air-conditioning and Refrigeration Institute (ARI) 95 F outdoor rating conditions, an active refrigerant flow control, and a variable-speed condenser fan. These features are expected to allow these units to operate at higher ambient temperatures (up to the maximum operating temperature of 110 F) with minimal degradation in performance. ORNL evaluated three potential manufacturers of advanced, gas-fired, 5-ton, aqua-ammonia chillers-Robur, Ambian, andmore » Cooling Technologies. Unfortunately, Robur did not meet the COP requirements and Cooling Technologies could not deliver a unit to be tested at the U.S. Department of Energy (DOE)-ORNL environmental chamber testing facility for thermally activated heat pumps. This eliminated these two technologies from further consideration, leaving only the Ambian chillers for evaluation. Two Ambian chillers were evaluated at the DOE-ORNL test facility. Overall these chillers operated well over a wide range of ambient conditions with minimal degradation in performance due to several control strategies used such as a variable speed condenser fan, a modulating burner, and active refrigerant flow control. These Ambian pre-commercial units were selected for installation and field testing at three federal facilities. NFESC worked with ORNL to assist with the site selection for installation and evaluation of these chillers. Two sites (ORNL and Naval Surface Warfare Center [NSWC] Corona) had a single chiller unit installed; and at one site (Naval Amphibious Base [NAB] Little Creek), two 5-ton chillers linked together were installed to provide 10 tons of cooling. A chiller link controller developed under this project was evaluated in the field test at Little Creek.« less
Fission Surface Power Technology Demonstration Unit Test Results
NASA Technical Reports Server (NTRS)
Briggs, Maxwell H.; Gibson, Marc A.; Geng, Steven M.; Sanzi, James L.
2016-01-01
The Fission Surface Power (FSP) Technology Demonstration Unit (TDU) is a system-level demonstration of fission power technology intended for use on manned missions to Mars. The Baseline FSP systems consists of a 190 kWt UO2 fast-spectrum reactor cooled by a primary pumped liquid metal loop. This liquid metal loop transfers heat to two intermediate liquid metal loops designed to isolate fission products in the primary loop from the balance of plant. The intermediate liquid metal loops transfer heat to four Stirling Power Conversion Units (PCU), each of which produce 12 kWe (48 kW total) and reject waste heat to two pumped water loops, which transfer the waste heat to titanium-water heat pipe radiators. The FSP TDU simulates a single leg of the baseline FSP system using an electrically heater core simulator, a single liquid metal loop, a single PCU, and a pumped water loop which rejects the waste heat to a Facility Cooling System (FCS). When operated at the nominal operating conditions (modified for low liquid metal flow) during TDU testing the PCU produced 8.9 kW of power at an efficiency of 21.7 percent resulting in a net system power of 8.1 kW and a system level efficiency of 17.2 percent. The reduction in PCU power from levels seen during electrically heated testing is the result of insufficient heat transfer from the NaK heater head to the Stirling acceptor, which could not be tested at Sunpower prior to delivery to the NASA Glenn Research Center (GRC). The maximum PCU power of 10.4 kW was achieved at the maximum liquid metal temperature of 875 K, minimum water temperature of 350 K, 1.1 kg/s liquid metal flow, 0.39 kg/s water flow, and 15.0 mm amplitude at an efficiency of 23.3 percent. This resulted in a system net power of 9.7 kW and a system efficiency of 18.7 percent.
Fission Surface Power Technology Demonstration Unit Test Results
NASA Technical Reports Server (NTRS)
Briggs, Maxwell H.; Gibson, Marc A.; Geng, Steven; Sanzi, James
2016-01-01
The Fission Surface Power (FSP) Technology Demonstration Unit (TDU) is a system-level demonstration of fission power technology intended for use on manned missions to Mars. The Baseline FSP systems consists of a 190 kWt UO2 fast-spectrum reactor cooled by a primary pumped liquid metal loop. This liquid metal loop transfers heat to two intermediate liquid metal loops designed to isolate fission products in the primary loop from the balance of plant. The intermediate liquid metal loops transfer heat to four Stirling Power Conversion Units (PCU), each of which produce 12 kWe (48 kW total) and reject waste heat to two pumped water loops, which transfer the waste heat to titanium-water heat pipe radiators. The FSP TDU simulates a single leg of the baseline FSP system using an electrically heater core simulator, a single liquid metal loop, a single PCU, and a pumped water loop which rejects the waste heat to a Facility Cooling System (FCS). When operated at the nominal operating conditions (modified for low liquid metal flow) during TDU testing the PCU produced 8.9 kW of power at an efficiency of 21.7% resulting in a net system power of 8.1 kW and a system level efficiency of 17.2%. The reduction in PCU power from levels seen during electrically heated testing is the result of insufficient heat transfer from the NaK heater head to the Stirling acceptor, which could not be tested at Sunpower prior to delivery to GRC. The maximum PCU power of 10.4 kW was achieved at the maximum liquid metal temperature of 875 K, minimum water temperature of 350 K, 1.1 kg/s liquid metal flow, 0.39 kg/s water flow, and 15.0 mm amplitude at an efficiency of 23.3%. This resulted in a system net power of 9.7 kW and a system efficiency of 18.7 %.
Thermocouple for heating and cooling of memory metal actuators
NASA Technical Reports Server (NTRS)
Wood, Charles (Inventor)
1988-01-01
A semiconductor thermocouple unit is provided for heating and cooling memory metal actuators. The semiconductor thermocouple unit is mounted adjacent to a memory metal actuator and has a heat sink attached to it. A flexible thermally conductive element extends between the semiconductor thermocouple and the actuator and serves as a heat transfer medium during heating and cooling operations.
DOE Office of Scientific and Technical Information (OSTI.GOV)
C. Withers; Cummings, J.; Nigusse, B.
A new generation of full variable-capacity, central, ducted air-conditioning (AC) and heat pump units has come on the market, and they promise to deliver increased cooling (and heating) efficiency. They are controlled differently than standard single-capacity (fixed-capacity) systems. Instead of cycling on at full capacity and then cycling off when the thermostat is satisfied, they can vary their capacity over a wide range (approximately 40% to 118% of nominal full capacity), thus staying “on” for up to twice as many hours per day compared to fixed-capacity systems of the same nominal capacity. The heating and cooling capacity is varied bymore » adjusting the indoor fan air flow rate, compressor, and refrigerant flow rate as well as the outdoor unit fan air flow rate. Note that two-stage AC or heat pump systems were not evaluated in this research effort. The term dwell is used to refer to the amount of time distributed air spends inside ductwork during space-conditioning cycles. Longer run times mean greater dwell time and therefore greater exposure to conductive gains and losses.« less
A lightweight ambient air-cooling unit for use in hazardous environments.
Chen, Y T; Constable, S H; Bomalaski, S H
1997-01-01
Recent research demonstrated (a) the effectiveness of intermittent conditioned air cooling during rest breaks to significantly reduce cumulative heat storage and (b) that longer work sessions were possible for individuals wearing chemical defense ensembles. To further advance this concept, a strategy for implementing continuous air cooling was conceived; ambient air cooling was added during work cycles and conditioned air cooling was delivered during rest periods. A compact battery-powered beltpack cooling unit (3.9 kg) designed and made at the U.S. Air Force Armstrong Laboratory was used to deliver 5.7 L/sec filtered ambient air during work cycles: 4.7 L/sec to the body and 1 L/sec to the face. Five experimental cycles were conducted in a thermally controlled chamber under warm conditions (32 degrees C, 40% relative humidity) with (1) no cooling-intermittent work, (2) intermittent cooling, (3) continuous cooling during intermittent exercise, and (4) no cooling-continuous work and (5) ambient air cooling during continuous exercise. Intermittent, conditioned, and continuous air cooling resulted in significant reductions in rectal temperature, mean skin temperature, and heart rate as compared with the no-cooling trials. The continuous air-cooling trial significantly improved thermal comfort and sweat evaporation. Results suggest that ambient air delivered during work cycles by a lightweight portable unit (in conjunction with conditioned air delivered during rest periods), can definitely improve personal comfort, reduce skin temperature, and decrease the cumulative fatigue common to repeated work/rest cycles in selected military and industrial applications in which individuals work in chemical defense ensembles.
Conduction cooling systems for linear accelerator cavities
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kephart, Robert
A conduction cooling system for linear accelerator cavities. The system conducts heat from the cavities to a refrigeration unit using at least one cavity cooler interconnected with a cooling connector. The cavity cooler and cooling connector are both made from solid material having a very high thermal conductivity of approximately 1.times.10.sup.4 W m.sup.-1 K.sup.-1 at temperatures of approximately 4 degrees K. This allows for very simple and effective conduction of waste heat from the linear accelerator cavities to the cavity cooler, along the cooling connector, and thence to the refrigeration unit.
A Preliminary Heat Flow Model for Cooling a Batholith near Ica, Peru
NASA Astrophysics Data System (ADS)
Gonzalez, L. U.; Clausen, B. L.; Molano, J. C.; Martinez, A. M.; Poma, O.
2014-12-01
This research models the cooling of a suite in the Linga Super-unit located at the north end of the Arequipa segment in the Cretaceous Peruvian Coastal Batholith. The monzogabbro to granite Linga suite is approximately 50 km long and 15 km wide, with an estimated vertical extent of about 5 km originally intruded to a depth of 3 km. The emplacement was in andesitic volcanics on the west and the Pampahuasi diorite Super-unit on the east and has incorporated earlier gabbroic bodies. The Linga suite is thought to be the result of a sequence of three pulses: an elongate unit to the west then two elliptical units to the northeast and southeast. The data for modeling comes from field observations on internal and external contacts, some well-defined magma chamber walls and roof, pendant and stoped blocks, magma chamber zoning, the nature and distribution of enclaves and xenoliths, magmatic fabric, evidences of magma mingling, rock porosity, mineralogical associations in metamorphic aureoles, extensive mineralization and brecciated conduits, and the types of hydrothermal alteration varying with distance from contacts. More than forty hand samples, thin sections, and geochemical analyses were used to estimate water content, magma and country rock temperature, liquid density, and viscosity. Further data will come from: zircon U-Pb ages for country rock and magma batch timeframes, fluid inclusions for magma pressure and temperature, and δ18O data for source of hydrothermal fluids. Simple heat conduction calculations using MATLAB and HEAT 3D for a single tabular intrusion estimated a cooling time to solidus of about 300 k.y. More complex modeling includes magma convection and multiple intrusions. Extensive veining and pervasive alteration suggested the use of HYDROTHERM to model possible additional heat flow effects from hydrothermal fluids. Extensive propylitic and significant potassic alteration were observed and, with TerraSpec infrared spectroscopy to identify mineralogical content of altered outcrops, fluid flux and temperatures were estimated. Rough calculations for cooling times are made using the modeling of Hayba and Ingebritsen (1997).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lykkebo, Jacob; Solomon, Gemma C., E-mail: gsolomon@nano.ku.dk; Romano, Giuseppe
Electronic devices composed of single molecules constitute the ultimate limit in the continued downscaling of electronic components. A key challenge for single-molecule electronics is to control the temperature of these junctions. Controlling heating and cooling effects in individual vibrational modes can, in principle, be utilized to increase stability of single-molecule junctions under bias, to pump energy into particular vibrational modes to perform current-induced reactions, or to increase the resolution in inelastic electron tunneling spectroscopy by controlling the life-times of phonons in a molecule by suppressing absorption and external dissipation processes. Under bias the current and the molecule exchange energy, whichmore » typically results in heating of the molecule. However, the opposite process is also possible, where energy is extracted from the molecule by the tunneling current. Designing a molecular “heat sink” where a particular vibrational mode funnels heat out of the molecule and into the leads would be very desirable. It is even possible to imagine how the vibrational energy of the other vibrational modes could be funneled into the “cooling mode,” given the right molecular design. Previous efforts to understand heating and cooling mechanisms in single molecule junctions have primarily been concerned with small models, where it is unclear which molecular systems they correspond to. In this paper, our focus is on suppressing heating and obtaining current-induced cooling in certain vibrational modes. Strategies for cooling vibrational modes in single-molecule junctions are presented, together with atomistic calculations based on those strategies. Cooling and reduced heating are observed for two different cooling schemes in calculations of atomistic single-molecule junctions.« less
A portable personal cooling system for mine rescue operations
NASA Technical Reports Server (NTRS)
Webbon, B.; Williams, B.; Kirk, P.; Elkins, W.; Stein, R.
1977-01-01
Design of a portable personal cooling system to reduce physiological stress in high-temperature, high-humidity conditions is discussed. The system, based on technology used in the thermal controls of space suits, employs a combination of head and thoracic insulation and cooling through a heat sink unit. Average metabolic rates, heart rates, rectal temperature increase and sweat loss were monitored for test subjects wearing various configurations of the cooling system, as well as for a control group. The various arrangements of the cooling garment were found to provide significant physiological benefits; however, increases in heat transfer rate of the cooling unit and more effective insulation are suggested to improve the system's function.
Spectroscopic and laser cooling results on Yb3+-doped BaY2F8 single crystal
NASA Astrophysics Data System (ADS)
Bigotta, Stefano; Parisi, Daniela; Bonelli, Lucia; Toncelli, Alessandra; Tonelli, Mauro; Di Lieto, Alberto
2006-07-01
Anti-Stokes cooling has been observed in an Yb3+-doped BaY2F8 single crystal. Single crystals have been grown by the Czochralski technique. The absorption spectra and the emission properties have been measured at room temperature and at 10K. The energy positions of the Stark sublevels of the ground and the excited state manifolds have been determined and separated from the vibronic substructure. The intrinsic decay time of the F5/22 level has been measured taking care of avoiding the effect of multiple reabsorption processes. The theoretical and experimental cooling efficiencies of Yb:BaY2F8 are evaluated and compared with respect to those of the most frequently investigated materials for laser cooling. A temperature drop of almost 4K was measured by pumping the crystal with 3W of laser radiation at ˜1025nm in single pass configuration with a cooling efficiency of ˜3%.
High-performance dual-speed CCD camera system for scientific imaging
NASA Astrophysics Data System (ADS)
Simpson, Raymond W.
1996-03-01
Traditionally, scientific camera systems were partitioned with a `camera head' containing the CCD and its support circuitry and a camera controller, which provided analog to digital conversion, timing, control, computer interfacing, and power. A new, unitized high performance scientific CCD camera with dual speed readout at 1 X 106 or 5 X 106 pixels per second, 12 bit digital gray scale, high performance thermoelectric cooling, and built in composite video output is described. This camera provides all digital, analog, and cooling functions in a single compact unit. The new system incorporates the A/C converter, timing, control and computer interfacing in the camera, with the power supply remaining a separate remote unit. A 100 Mbyte/second serial link transfers data over copper or fiber media to a variety of host computers, including Sun, SGI, SCSI, PCI, EISA, and Apple Macintosh. Having all the digital and analog functions in the camera made it possible to modify this system for the Woods Hole Oceanographic Institution for use on a remote controlled submersible vehicle. The oceanographic version achieves 16 bit dynamic range at 1.5 X 105 pixels/second, can be operated at depths of 3 kilometers, and transfers data to the surface via a real time fiber optic link.
Storage peak gas-turbine power unit
NASA Technical Reports Server (NTRS)
Tsinkotski, B.
1980-01-01
A storage gas-turbine power plant using a two-cylinder compressor with intermediate cooling is studied. On the basis of measured characteristics of a .25 Mw compressor computer calculations of the parameters of the loading process of a constant capacity storage unit (05.3 million cu m) were carried out. The required compressor power as a function of time with and without final cooling was computed. Parameters of maximum loading and discharging of the storage unit were calculated, and it was found that for the complete loading of a fully unloaded storage unit, a capacity of 1 to 1.5 million cubic meters is required, depending on the final cooling.
6. UNIT VENTILATOR, WOMEN'S COOLING ROOM. Hot Springs National ...
6. UNIT VENTILATOR, WOMEN'S COOLING ROOM. - Hot Springs National Park, Bathhouse Row, Ozark Bathhouse: Mechanical & Piping Systems, State Highway 7, 1 mile north of U.S. Highway 70, Hot Springs, Garland County, AR
Liquid cooled brassiere and method of diagnosing malignant tumors therewith
NASA Technical Reports Server (NTRS)
Elkins, W.; Williams, B. A.; Tickner, E. G. (Inventor)
1976-01-01
A device for enhancing the detection of malignant tissue in the breasts of a woman was described. A brassiere-like garment which is fitted with a pair of liquid-perfused cooling panels which completely and compliantly cover the breasts and upper torso was studied. The garment is connected by plastic tubing to a liquid cooling system comprising a fluid pump, a solenoid control valve for controlling the flow of fluid to either the cooling unit or the heating unit, a fluid reservoir, a temperature sensor in the reservoir, and a restrictor valve to control the pressure in the garment inlet cooling line.
Apparatus for production of ultrapure amorphous metals utilizing acoustic cooling
NASA Technical Reports Server (NTRS)
Lee, M. C. (Inventor)
1985-01-01
Amorphous metals are produced by forming a molten unit of metal and deploying the unit into a bidirectional acoustical levitating field or by dropping the unit through a spheroidizing zone, a slow quenching zone, and a fast quenching zone in which the sphere is rapidly cooled by a bidirectional jet stream created in the standing acoustic wave field produced between a half cylindrical acoustic driver and a focal reflector or a curved driver and a reflector. The cooling rate can be further augmented first by a cryogenic liquid collar and secondly by a cryogenic liquid jacket surrounding a drop tower. The molten unit is quenched to an amorphous solid which can survive impact in a unit collector or is retrieved by a vacuum chuck.
10 CFR 429.43 - Commercial heating, ventilating, air conditioning (HVAC) equipment.
Code of Federal Regulations, 2014 CFR
2014-01-01
... conditioners: The energy efficiency ratio (EER in British thermal units per Watt-hour (Btu/Wh)), the cooling...) Package terminal heat pumps: The energy efficiency ratio (EER in British thermal units per Watt-hour (Btu...: The energy efficiency ratio (EER in British thermal units per Watt-hour (Btu/Wh)) and the cooling...
Silicon Oil DC200(R)5CST as AN Alternative Coolant for Cvd Diamond Windows
NASA Astrophysics Data System (ADS)
Vaccaro, A.; Aiello, G.; Meier, A.; Schere, T.; Schreck, S.; Spaeh, P.; Strauss, D.; Gantenbein, G.
2011-02-01
The production of high power mm-wave radiation is a key technology in large fusion devices, since it is required for localized plasma heating and current drive. Transmission windows are necessary to keep the vacuum in the gyrotron system and also act as tritium barriers. With its excellent optical, thermal and mechanical properties, synthetic CVD (Chemical Vapor Deposition) diamond is the state of the art material for the cw transmission of the mm-wave beams produced by high power gyrotrons. The gyrotrons foreseen for the W7-X stellarator are designed for cw operation with 1 MW output power at 140 GHz. The output window unit is designed by TED (Thales Electron Devices, France) using a single edge circumferentially cooled CVD-diamond disc with an aperture of 88 mm. The window unit is cooled by de-ionized water which is considered as chemical aggressive and might cause corrosion in particular at the brazing. The use of a different coolant such as silicon oil could prevent this issue. The cooling circuit has been simulated by steady-state CFD analysis. A total power generation of 1 kW (RF transmission losses) with pure Gaussian distribution has been assumed for the diamond disc. The performance of both water and the industrial silicon oil DC200(R) have been investigated and compared with a focus on the temperature distribution on the disc, the pressure drop across the cooling path and the heat flux distribution. Although the silicon oil has a higher viscosity (~x5), lower heat capacity (~x1/2) and lower thermal conductivity (~x1/3), it has proven to be a good candidate as alternative to water.
DESI focal plate mechanical integration and cooling
NASA Astrophysics Data System (ADS)
Lambert, A. R.; Besuner, R. W.; Claybaugh, T. M.; Silber, J. H.
2016-08-01
The Dark Energy Spectroscopic Instrument (DESI) is under construction to measure the expansion history of the Universe using the Baryon Acoustic Oscillation technique[1]. The spectra of 40 million galaxies over 14000 sq. deg will be measured during the life of the experiment. A new prime focus corrector for the KPNO Mayall telescope will deliver light to 5000 fiber optic positioners. The fibers in turn feed ten broad-band spectrographs. This paper describes the mechanical integration of the DESI focal plate and the thermal system design. The DESI focal plate is comprised of ten identical petal assemblies. Each petal contains 500 robotic fiber positioners. Each petal is a complete, self-contained unit, independent from the others, with integrated power supply, controllers, fiber routing, and cooling services. The major advantages of this scheme are: (1) supports installation and removal of complete petal assemblies in-situ, without disturbing the others, (2) component production, assembly stations, and test procedures are repeated and parallelizable, (3) a complete, full-scale prototype can be built and tested at an early date, (4) each production petal can be surveyed and tested as a complete unit, prior to integration, from the fiber tip at the focal surface to the fiber slit at the spectrograph. The ten petal assemblies will be installed in a single integration ring, which is mounted to the DESI corrector. The aluminum integration ring attaches to the steel corrector barrel via a flexured steel adapter, isolating the focal plate from differential thermal expansions. The plate scale will be kept stable by conductive cooling of the petal assembly. The guider and wavefront sensors (one per petal) will be convectively cooled by forced flow of air. Heat will be removed from the system at ten liquid-cooled cold plates, one per petal, operating at ambient temperature. The entire focal plate structure is enclosed in an insulating shroud, which serves as a thermal barrier between the heat-generating focal plate components and the ambient air of the Mayall dome, to protect the seeing[2].
Preliminary design package for residential heating/cooling system: Rankine air conditioner redesign
NASA Technical Reports Server (NTRS)
1978-01-01
A summary of the preliminary redesign and development of a marketable single family heating and cooling system is presented. The interim design and schedule status of the residential (3-ton) redesign, problem areas and solutions, and the definition of plans for future design and development activities were discussed. The proposed system for a single-family residential heating and cooling system is a single-loop, solar-assisted, hydronic-to-warm-air heating subsystem with solar-assisted domestic water heating and a Rankine-driven expansion air-conditioning subsystem.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1979-07-01
The objective of the work described in this volume was to conceptualize suitable designs for solar total energy systems for the following residential market segments: single-family detached homes, single-family attached units (townhouses), low-rise apartments, and high-rise apartments. Conceptual designs for the total energy systems are based on parabolic trough collectors in conjunction with a 100 kWe organic Rankine cycle heat engine or a flat-plate, water-cooled photovoltaic array. The ORC-based systems are designed to operate as either independent (stand alone) systems that burn fossil fuel for backup electricity or as systems that purchase electricity from a utility grid for electrical backup.more » The ORC designs are classified as (1) a high temperature system designed to operate at 600/sup 0/F and (2) a low temperature system designed to operate at 300/sup 0/F. The 600/sup 0/F ORC system that purchases grid electricity as backup utilizes the thermal tracking principle and the 300/sup 0/F ORC system tracks the combined thermal and electrical loads. Reject heat from the condenser supplies thermal energy for heating and cooling. All of the ORC systems utilize fossil fuel boilers to supply backup thermal energy to both the primary (electrical generating) cycle and the secondary (thermal) cycle. Space heating is supplied by a central hot water (hydronic) system and a central absorption chiller supplies the space cooling loads. A central hot water system supplies domestic hot water. The photovoltaic system uses a central electrical vapor compression air conditioning system for space cooling, with space heating and domestic hot water provided by reject heat from the water-cooled array. All of the systems incorporate low temperature thermal storage (based on water as the storage medium) and lead--acid battery storage for electricity; in addition, the 600/sup 0/F ORC system uses a therminol-rock high temperature storage for the primary cycle. (WHK)« less
Water requirements of the petroleum refining industry
Otts, Louis Ethelbert
1964-01-01
About 3,500 million gallons of water was withdrawn daily in 1955 for use by petroleum refineries in the United States. This was about 3 percent of the estimated daily withdrawal of industrial water in the United States in 1955. An average of 468 gallons of water was required to refine a barrel of crude oil, and the median was 95 gallons of water per barrel of crude charge; withdrawals ranged from 6.5 to 3,240 gallons per barrel. Ninety-one percent of the water requirements of the petroleum refineries surveyed was for cooling. One-third of the refineries reused their cooling water from 10 to more than 50 times. Only 17 refineries used once-through cooling systems. Refineries with recirculating cooling systems circulated about twice as much cooling water but needed about 25 times less makeup; however, they consumed about 24 times more water per barrel of charge than refineries using once-through cooling systems. The average noncracking refinery used about 375 gallons of water per barrel of crude, which is less than the 471-gallon average of refineries with cracking facilities. Refineries are composed of various processing units, and the water requirements of such units varied ; median makeup needs ranged from about 125 gallons per barrel for polymerization and alkylation units to 15.5 gallons per barrel for distillation units. Refinery-owned sources of water supplied 95 percent of the makeup-water requirements. Surface-water sources provided 86 percent of the makeup-water demand. Less than 1 percent of the makeup water was obtained from reprocessed municipal sewage.
High-order corrections on the laser cooling limit in the Lamb-Dicke regime.
Yi, Zhen; Gu, Wen-Ju
2017-01-23
We investigate corrections on the cooling limit of high-order Lamb-Dicke (LD) parameters in the double electromagnetically induced transparency (EIT) cooling scheme. Via utilizing quantum interferences, the single-phonon heating mechanism vanishes and the system evolves to a double dark state, from which we will obtain the mechanical occupation on the single-phonon excitation state. In addition, the further correction induced by two-phonon heating transitions is included to achieve a more accurate cooling limit. There exist two pathways of two-phonon heating transitions: direct two-phonon excitation from the dark state and further excitation from the single-phonon excited state. By adding up these two parts of correction, the obtained analytical predictions show a well consistence with numerical results. Moreover, we find that the two pathways can destructively interfere with each other, leading to the elimination of two-phonon heating transitions and achieving a lower cooling limit.
Extended range of the Lockheed Martin Mini cryocooler
NASA Astrophysics Data System (ADS)
Frank, D.; Sanders, L.; Nason, I.; Mistry, V.; Guzinski, M.; Roth, E.; Olson, J. R.
2017-12-01
This paper describes the expanded performance range of the Lockheed Martin Mini cryocooler thermal mechanical unit (TMU). The design is based on the standard unit originally developed for NASA and a higher capacity developed for ESA. These higher capacity Mini units are in a split configuration with the cold head separated from the compressor. The TMU provides cooling over a wide range of temperatures with a weight of 1.9 kg including the 1.4 kg compressor and the 0.45 kg cold head. The unit provides for 3.5 W cooling at 105 K and approximately 7 W cooling at 150 K for 293 K reject temperature with 60 W of input power.
Kinematic cooling of molecules in a magneto-optical trap
NASA Astrophysics Data System (ADS)
Takase, Ken; Chandler, David W.; Strecker, Kevin E.
2008-05-01
We will present our current progress on a new experimental technique aimed at slowing and cooling hot molecules using a single collision with magneto-optically trapped atoms. Kinematic cooling, unlike buffer gas and sympathetic cooling, relies only on a single collision between the molecule and atom to stop the molecule in the laboratory frame. This technique has recently been demonstrated in a crossed atomic and molecular beam machine to produce 35mK samples of nitric oxide via a single collision with argon [1]. In this technique we replace the atomic beam with a sample magneto-optically trapped atoms. We are currently designing and building a new apparatus to attempt these experiments. [1] Kevin E. Strecker and David W. Chandler (to be published)
Hydronic rooftop cooling systems
Bourne, Richard C [Davis, CA; Lee, Brian Eric [Monterey, CA; Berman, Mark J [Davis, CA
2008-01-29
A roof top cooling unit has an evaporative cooling section that includes at least one evaporative module that pre-cools ventilation air and water; a condenser; a water reservoir and pump that captures and re-circulates water within the evaporative modules; a fan that exhausts air from the building and the evaporative modules and systems that refill and drain the water reservoir. The cooling unit also has a refrigerant section that includes a compressor, an expansion device, evaporator and condenser heat exchangers, and connecting refrigerant piping. Supply air components include a blower, an air filter, a cooling and/or heating coil to condition air for supply to the building, and optional dampers that, in designs that supply less than 100% outdoor air to the building, control the mixture of return and ventilation air.
A Compact, High-Performance Continuous Magnetic Refrigerator
NASA Technical Reports Server (NTRS)
Shirron, Peter; Canavan, Edgar; DiPirro, Michael; Jackson, Michael; King, Todd; Panek, John; Tuttle, James; Brodeur, Stephen J. (Technical Monitor)
2001-01-01
We present test results of the first adiabatic demagnetization refrigerator (ADR) that can produce continuous cooling at sub-kelvin temperatures. This system uses multiple stages that operate in sequence to cascade heat from a continuous stage up to a heat sink. Continuous operation aids the usual constraints of long hold times and short recycle times that lead to the generally large mass of single-shot ADRs, and allows us to achieve much higher cooling power per unit mass. Our design goal is 10 microW of cooling at 50 mK while rejecting heat to a 6-10 K heat sink. The total cold mass is estimated to be less than 10 kg, including magnetic shielding of each stage. These parameters envelop the requirements for currently planned astronomy missions. The relatively high heat rejection capability allows it to operate with a mechanical cryocooler as part of a cryogen-free, low temperature cooling system. This has the advantages of long, mission life and reduced complexity and cost. At present, we have assembled a three-stage ADR that operates with a superfluid helium bath. Additional work is underway to develop magnetocaloric materials that can extend its heat rejection capability up to 10 K. This paper discusses the design and operation of the ADR, as well as interface requirements for cryocooler-based operation.
Annular feed air breathing fuel cell stack
Wilson, Mahlon S.; Neutzler, Jay K.
1997-01-01
A stack of polymer electrolyte fuel cells is formed from a plurality of unit cells where each unit cell includes fuel cell components defining a periphery and distributed along a common axis, where the fuel cell components include a polymer electrolyte membrane, an anode and a cathode contacting opposite sides of the membrane, and fuel and oxygen flow fields contacting the anode and the cathode, respectively, wherein the components define an annular region therethrough along the axis. A fuel distribution manifold within the annular region is connected to deliver fuel to the fuel flow field in each of the unit cells. The fuel distribution manifold is formed from a hydrophilic-like material to redistribute water produced by fuel and oxygen reacting at the cathode. In a particular embodiment, a single bolt through the annular region clamps the unit cells together. In another embodiment, separator plates between individual unit cells have an extended radial dimension to function as cooling fins for maintaining the operating temperature of the fuel cell stack.
4. INTERIOR VIEW OF CLUB HOUSE REFRIGERATION UNIT, SHOWING COOLING ...
4. INTERIOR VIEW OF CLUB HOUSE REFRIGERATION UNIT, SHOWING COOLING COILS AND CORK-LINED ROOM. CAMERA IS BETWEEN SEVEN AND EIGHT FEET ABOVE FLOOR LEVEL, FACING SOUTHEAST. - Swan Falls Village, Clubhouse 011, Snake River, Kuna, Ada County, ID
Performance of Variable Capacity Heat Pumps in a Mixed Humid Climate
DOE Office of Scientific and Technical Information (OSTI.GOV)
Munk, Jeffrey D; Gehl, Anthony C; Jackson, Roderick K
2012-04-01
Variable capacity heat pumps represent the next wave of technology for heat pumps. In this report, the performance of two variable capacity heat pumps (HPs) is compared to that of a single or two stage baseline system. The units were installed in two existing research houses located in Knoxville, TN. These houses were instrumented to collect energy use and temperature data while both the baseline systems and variable capacity systems were installed. The homes had computer controlled simulated occupancy, which provided consistent schedules for hot water use and lighting. The temperature control and energy use of the systems were comparedmore » during both the heating and cooling seasons. Multiple linear regression models were used along with TMY3 data for Knoxville, TN in order to normalize the effect that the outdoor air temperature has on energy use. This enables a prediction of each system's energy use over a year with the same weather. The first system was a multi-split system consisting of 8 indoor units and a single outdoor unit. This system replaced a 16 SEER single stage HP with a zoning system, which served as the baseline. Data was collected on the baseline system from August 2009 to December 2010 and on the multi-split system from January 2011 to January 2012. Soon after the installation of the multi-split system, some of the smaller rooms began over-conditioning. This was determined to be caused by a small amount of continuous refrigerant flow to all of the indoor units when the outdoor unit was running regardless of whether they were calling for heat. This, coupled with the fact that the indoor fans run continuously, was providing enough heat in some rooms to exceed the set point. In order to address this, the indoor fans were disabled when not actively heating per the manufacturer's recommendation. Based on the measured data, the multi-split system was predicted to use 40% more energy in the heating season and 16% more energy in the cooling season than the baseline system, for the typical meteorological year weather data. The AHRI ratings indicated that the baseline system would perform slightly better than the multi-split system, but not by as large of a margin as seen in this study. The multi-split system was able to maintain more consistent temperature throughout the house than the baseline system, but it did allow relative humidity levels to increase above 60% in the summer. The second system was a split system with an inverter driven compressor and a single ducted air handler. This unit replaced a 16 SEER two stage HP with a zoning system. Data was collected on the baseline system from July 2009 to November 2010 and on the ducted inverter system from December 2010 to January 2012. The ducted inverter system did not offer a zone controller, so it functioned as a single zone system. Due to this fact, the registers had to be manually adjusted in order to better maintain consistent temperatures between the two levels of the house. The predicted heating season energy use for the ducted inverter system, based on the measured energy use, was 30% less than that of the baseline system for the typical meteorological year. However, the baseline system was unable to operate in its high stage due to a wiring issue with the zone controller. This resulted in additional resistance heat use during the winter and therefore higher energy use than would be expected in a properly performing unit. The AHRI ratings would indicate that the baseline system would use less energy than the ducted inverter system, which is opposite to the results of this study. During the cooling season, the ducted inverter system was predicted to use 23% more energy than the baseline system during the typical meteorological year. This is also opposite of the results expected by comparing the AHRI ratings. After a detailed comparison of the ducted inverter system's power use compared to that of a recently installed identical system at a retro-fit study house, there is concern that the unit is not operating as intended. The power use and cycles indicate that the unit is performing more like a single stage unit than a variable capacity unit. Analysis of the data indicates that a change in operating behavior occurred during a service call shortly after the installation of the unit. The logbook only indicates that refrigerant charge was added, but does not indicate any other change. This is being investigated further. While the energy comparison results of these two variable capacity heat pumps is generally underwhelming, it is difficult to draw any hard conclusions about the maximum attainable efficiency of these units when optimally installed. Both units appear to have undesirable conditions associated with the installation or operation, which could have had an adverse effect on their energy use.« less
Enhanced electrocaloric cooling in ferroelectric single crystals by electric field reversal
NASA Astrophysics Data System (ADS)
Ma, Yang-Bin; Novak, Nikola; Koruza, Jurij; Yang, Tongqing; Albe, Karsten; Xu, Bai-Xiang
2016-09-01
An improved thermodynamic cycle is validated in ferroelectric single crystals, where the cooling effect of an electrocaloric refrigerant is enhanced by applying a reversed electric field. In contrast to the conventional adiabatic heating or cooling by on-off cycles of the external electric field, applying a reversed field is significantly improving the cooling efficiency, since the variation in configurational entropy is increased. By comparing results from computer simulations using Monte Carlo algorithms and experiments using direct electrocaloric measurements, we show that the electrocaloric cooling efficiency can be enhanced by more than 20% in standard ferroelectrics and also relaxor ferroelectrics, like Pb (Mg1 /3 /Nb2 /3)0.71Ti0.29O3 .
Favoured local structures in liquids and solids: a 3D lattice model.
Ronceray, Pierre; Harrowell, Peter
2015-05-07
We investigate the connection between the geometry of Favoured Local Structures (FLS) in liquids and the associated liquid and solid properties. We introduce a lattice spin model - the FLS model on a face-centered cubic lattice - where this geometry can be arbitrarily chosen among a discrete set of 115 possible FLS. We find crystalline groundstates for all choices of a single FLS. Sampling all possible FLS's, we identify the following trends: (i) low symmetry FLS's produce larger crystal unit cells but not necessarily higher energy groundstates, (ii) chiral FLS's exhibit peculiarly poor packing properties, (iii) accumulation of FLS's in supercooled liquids is linked to large crystal unit cells, and (iv) low symmetry FLS's tend to find metastable structures on cooling.
AUTOMOTIVE DIESEL MAINTENANCE 1. UNIT IV, MAINTAINING THE COOLING SYSTEM--DETROIT DIESEL ENGINES.
ERIC Educational Resources Information Center
Human Engineering Inst., Cleveland, OH.
THIS MODULE OF A 30-MODULE COURSE IS DESIGNED TO DEVELOP AN UNDERSTANDING OF THE OPERATION AND MAINTENANCE OF THE DIESEL ENGINE COOLING SYSTEM. TOPICS ARE PURPOSE OF THE COOLING SYSTEM, CARE MAINTENANCE OF THE COOLING SYSTEM, COOLING SYSTEM COMPONENTS, AND TROUBLESHOOTING TIPS. THE MODULE CONSISTS OF A SELF-INSTRUCTIONAL BRANCH PROGRAMED TRAINING…
Efficient rotational cooling of Coulomb-crystallized molecular ions by a helium buffer gas.
Hansen, A K; Versolato, O O; Kłosowski, L; Kristensen, S B; Gingell, A; Schwarz, M; Windberger, A; Ullrich, J; López-Urrutia, J R Crespo; Drewsen, M
2014-04-03
The preparation of cold molecules is of great importance in many contexts, such as fundamental physics investigations, high-resolution spectroscopy of complex molecules, cold chemistry and astrochemistry. One versatile and widely applied method to cool molecules is helium buffer-gas cooling in either a supersonic beam expansion or a cryogenic trap environment. Another more recent method applicable to trapped molecular ions relies on sympathetic translational cooling, through collisional interactions with co-trapped, laser-cooled atomic ions, into spatially ordered structures called Coulomb crystals, combined with laser-controlled internal-state preparation. Here we present experimental results on helium buffer-gas cooling of the rotational degrees of freedom of MgH(+) molecular ions, which have been trapped and sympathetically cooled in a cryogenic linear radio-frequency quadrupole trap. With helium collision rates of only about ten per second--that is, four to five orders of magnitude lower than in typical buffer-gas cooling settings--we have cooled a single molecular ion to a rotational temperature of 7.5(+0.9)(-0.7) kelvin, the lowest such temperature so far measured. In addition, by varying the shape of, or the number of atomic and molecular ions in, larger Coulomb crystals, or both, we have tuned the effective rotational temperature from about 7 kelvin to about 60 kelvin by changing the translational micromotion energy of the ions. The extremely low helium collision rate may allow for sympathetic sideband cooling of single molecular ions, and eventually make quantum-logic spectroscopy of buffer-gas-cooled molecular ions feasible. Furthermore, application of the present cooling scheme to complex molecular ions should enable single- or few-state manipulations of individual molecules of biological interest.
Effects of internal gain assumptions in building energy calculations
NASA Astrophysics Data System (ADS)
Christensen, C.; Perkins, R.
1981-01-01
The utilization of direct solar gains in buildings can be affected by operating profiles, such as schedules for internal gains, thermostat controls, and ventilation rates. Building energy analysis methods use various assumptions about these profiles. The effects of typical internal gain assumptions in energy calculations are described. Heating and cooling loads from simulations using the DOE 2.1 computer code are compared for various internal gain inputs: typical hourly profiles, constant average profiles, and zero gain profiles. Prototype single-family-detached and multifamily-attached residential units are studied with various levels of insulation and infiltration. Small detached commercial buildings and attached zones in large commercial buildings are studied with various levels of internal gains. The results indicate that calculations of annual heating and cooling loads are sensitive to internal gains, but in most cases are relatively insensitive to hourly variations in internal gains.
Dual-stroke heat pump field performance
NASA Astrophysics Data System (ADS)
Veyo, S. E.
1984-11-01
Two nearly identical proprototype systems, each employing a unique dual-stroke compressor, were built and tested. One was installed in an occupied residence in Jeannette, Pa. It has provided the heating and cooling required from that time to the present. The system has functioned without failure of any prototypical advanced components, although early field experience did suffer from deficiencies in the software for the breadboard micro processor control system. Analysis of field performance data indicates a heating performance factor (HSPF) of 8.13 Stu/Wa, and a cooling energy efficiency (SEER) of 8.35 Scu/Wh. Data indicate that the beat pump is oversized for the test house since the observed lower balance point is 3 F whereas 17 F La optimum. Oversizing coupled with the use of resistance heat ot maintain delivered air temperature warmer than 90 F results in the consumption of more resistance heat than expected, more unit cycling, and therefore lower than expected energy efficiency. Our analysis indicates that with optimal mixing the dual stroke heat pump will yield as HSFF 30% better than a single capacity heat pump representative of high efficiency units in the market place today for the observed weather profile.
NASA Technical Reports Server (NTRS)
1975-01-01
Liquid cooled garments employed in several applications in which severe heat is encountered are discussed. In particular, the use of the garments to replace air line cooling units in a variety of industrial processing situations is discussed.
Experiences in solar cooling systems
NASA Astrophysics Data System (ADS)
Ward, D. S.
The results of performance evaluations for nine solar cooling systems are presented, and reasons fow low or high net energy balances are discussed. Six of the nine systems are noted to have performed unfavorably compared to standard cooling systems due to thermal storage losses, excessive system electrical demands, inappropriate control strategies, poor system-to-load matching, and poor chiller performance. A reduction in heat losses in one residential unit increased the total system efficiency by 2.5%, while eliminating heat losses to the building interior increased the efficiency by 3.3%. The best system incorporated a lithium bromide absorption chiller and a Rankine cycle compression unit for a commercial application. Improvements in the cooling tower and fan configurations to increase the solar cooling system efficiency are indicated. Best performances are expected to occur in climates inducing high annual cooling loads.
Process of making cryogenically cooled high thermal performance crystal optics
Kuzay, Tuncer M.
1992-01-01
A method for constructing a cooled optic wherein one or more cavities are milled, drilled or formed using casting or ultrasound laser machining techniques in a single crystal base and filled with porous material having high thermal conductivity at cryogenic temperatures. A non-machined strain-free single crystal can be bonded to the base to produce superior optics. During operation of the cooled optic, N.sub.2 is pumped through the porous material at a sub-cooled cryogenic inlet temperature and with sufficient system pressure to prevent the fluid bulk temperature from reaching saturation.
Process of making cryogenically cooled high thermal performance crystal optics
Kuzay, T.M.
1992-06-23
A method is disclosed for constructing a cooled optic wherein one or more cavities are milled, drilled or formed using casting or ultrasound laser machining techniques in a single crystal base and filled with porous material having high thermal conductivity at cryogenic temperatures. A non-machined strain-free single crystal can be bonded to the base to produce superior optics. During operation of the cooled optic, N[sub 2] is pumped through the porous material at a sub-cooled cryogenic inlet temperature and with sufficient system pressure to prevent the fluid bulk temperature from reaching saturation. 7 figs.
Fast cool-down coaxial pulse tube microcooler
NASA Astrophysics Data System (ADS)
Nast, T.; Olson, J. R.; Champagne, P.; Roth, E.; Kaldas, G.; Saito, E.; Loung, V.; McCay, B. S.; Kenton, A. C.; Dobbins, C. L.
2016-09-01
We report the development and initial testing of the Lockheed Martin first-article, single-stage, compact, coaxial, Fast Cooldown Pulse Tube Microcryocooler (FC-PTM). The new cryocooler supports cooling requirements for emerging large, high operating temperature (105-150K) infrared focal plane array sensors with nominal cooling loads of 300 mW @105K @293K ambient. This is a sequel development that builds on our inline and coaxial pulse tube microcryocoolers reported at CEC 20137, ICC188,9, and CEC201510. The new FC-PTM and the prior units all share our long life space technology attributes, which typically have 10 year life requirements1. The new prototype microcryocooler builds on the previous development by incorporating cold head design improvements in two key areas: 1) reduced cool-down time and 2) novel repackaging that greatly reduces envelope. The new coldhead and Dewar were significantly redesigned from the earlier versions in order to achieve a cooldown time of 2-3 minutes- a projected requirement for tactical applications. A design approach was devised to reduce the cold head length from 115mm to 55mm, while at the same time reducing cooldown time. We present new FC-PTM performance test measurements with comparisons to our previous pulse-tube microcryocooler measurements and design predictions. The FC-PTM exhibits attractive small size, volume, weight, power and cost (SWaP-C) features with sufficient cooling capacity over required ambient conditions that apply to an increasing variety of space and tactical applications.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cornejo, J. M.; Colombano, M.; Doménech, J.
A special ion trap was initially built up to perform β-ν correlation experiments with radioactive ions. The trap geometry is also well suited to perform experiments with laser-cooled ions, serving for the development of a new type of Penning trap, in the framework of the project TRAPSENSOR at the University of Granada. The goal of this project is to use a single {sup 40}Ca{sup +} ion as detector for single-ion mass spectrometry. Within this project and without any modification to the initial electrode configuration, it was possible to perform Doppler cooling on {sup 40}Ca{sup +} ions, starting from large cloudsmore » and reaching single ion sensitivity. This new feature of the trap might be important also for other experiments with ions produced at radioactive ion beam facilities. In this publication, the trap and the laser system will be described, together with their performance with respect to laser cooling applied to large ion clouds down to a single ion.« less
Using Field-Metered Data to Quantify Annual Energy Use of Portable Air Conditioners
DOE Office of Scientific and Technical Information (OSTI.GOV)
Burke, Thomas; Willem, Henry; Ni, Chun Chun
2014-12-12
As many regions of the United States experience rising temperatures, consumers have come to rely increasingly on cooling appliances (including portable air conditioners) to provide a comfortable indoor temperature. Home occupants sometimes use a portable air conditioner (PAC) to maintain a desired indoor temperature in a single room or enclosed space. Although PACs in residential use are few compared to centrally installed and room air conditioning (AC) units, the past few years have witnessed an increase of PACs use throughout the United States. There is, however, little information and few research projects focused on the energy consumption and performance ofmore » PACs, particularly studies that collect information from field applications of PACs. The operation and energy consumption of PACs may differ among geographic locations and households, because of variations in cooling load, frequency, duration of use, and other user-selected settings. In addition, the performance of building envelope (thermal mass and air leakage) as well as inter-zonal mixing within the building would substantially influence the ability to control and maintain desirable indoor thermal conditions. Lawrence Berkeley National Laboratory (LBNL) conducted an initial field-metering study aimed at increasing the knowledge and data related to PAC operation and energy consumption in the United States. LBNL performed its field-metering study from mid-April to late October 2014. The study, which monitored 19 sites in the Northeastern United States (4 in upstate New York and 15 near Philadelphia), collected real-time data on PAC energy consumption along with information regarding housing characteristics, consumer behavior, and environmental conditions that were expected to affect PAC performance. Given the limited number of test sites, this study was not intended to be statistically representative of PAC users in the United States but rather to understand the system response to the cooling demand and to some extent, the operating hours of the studied units. Specifically, the primary objectives of the field-metering study were to (1) expand knowledge of the installation, energy consumption profiles, consumer patterns of use, and environmental parameters related to PAC use; (2) develop distributions of hours of PAC operation for three operating modes: standby, 1 fan-only, and cooling; and (3) describe how individual consumers’ selection of PAC capacity, the area of the space to be cooled, the temperature set point, and environmental conditions affect energy use. Beginning to understand the energy consumption of PACs operating in American homes and commercial settings will help develop a more accurate energy use profile that characterizes relevant variables. This report on LBNL’s field-metering study of PAC energy use describes: a general definition of a PAC and how it operates (section 2); current practices and sources of data for estimating PAC energy use (section 3); the process LBNL used to select field-metering sites, along with characteristics of the sites and the PACs studied (section 4); data collection methods and instrumentation (section 5); analysis methods (section 6); results and discussion (section 7); and conclusions (section 8).« less
Continuous parametric feedback cooling of a single atom in an optical cavity
NASA Astrophysics Data System (ADS)
Sames, C.; Hamsen, C.; Chibani, H.; Altin, P. A.; Wilk, T.; Rempe, G.
2018-05-01
We demonstrate a feedback algorithm to cool a single neutral atom trapped inside a standing-wave optical cavity. The algorithm is based on parametric modulation of the confining potential at twice the natural oscillation frequency of the atom, in combination with fast and repetitive atomic position measurements. The latter serve to continuously adjust the modulation phase to a value for which parametric excitation of the atomic motion is avoided. Cooling is limited by the measurement backaction which decoheres the atomic motion after only a few oscillations. Nonetheless, applying this feedback scheme to an ˜5 -kHz oscillation mode increases the average storage time of a single atom in the cavity by a factor of 60 to more than 2 s. In contrast to previous feedback schemes, our algorithm is also capable of cooling a much faster ˜500 -kHz oscillation mode within just microseconds. This demonstrates that parametric cooling is a powerful technique that can be applied in all experiments where optical access is limited.
Code of Federal Regulations, 2013 CFR
2013-07-01
... as a home, consisting of one residential unit only and not containing any business unit. Energy... a solar heating system, a solar heating and cooling system, or a combined solar heating and cooling system, or through application of a residential energy conservation measure as prescribed in 38 U.S.C...
Code of Federal Regulations, 2014 CFR
2014-07-01
... as a home, consisting of one residential unit only and not containing any business unit. Energy... a solar heating system, a solar heating and cooling system, or a combined solar heating and cooling system, or through application of a residential energy conservation measure as prescribed in 38 U.S.C...
Code of Federal Regulations, 2012 CFR
2012-07-01
... as a home, consisting of one residential unit only and not containing any business unit. Energy... a solar heating system, a solar heating and cooling system, or a combined solar heating and cooling system, or through application of a residential energy conservation measure as prescribed in 38 U.S.C...
NASA Astrophysics Data System (ADS)
Abdullah, M. A.; Tamaldin, N.; Rusnandi, H.; Manoharan, T.; Samsir, M. A.
2013-12-01
The engine that was chosen to be developed and modified is Yamaha LC 135 Single Overhead Camshaft (SOHC) 4-valve 4-stroke 135cc liquid-cooled engine. The engine selection is based on the specification, rule and regulation in UTeM Formula Varsity 2012 (FV 2012). The engine performance is determined by engine operating characteristics. The engine air flow affects the filtration, intake and exhaust systems. The heat from the engine rejected to the surrounding through the active cooling system which has radiator and fan. The selection of the engine is based on weighted decision matrix which consists of reliability, operating and maintenance cost, fuel consumption and weight. The score of the matrix is formulated based on relative weighted factor among the selections. It been compared between Yamaha LC 135 Single Overhead Camshaft (SOHC) 4-valve 4-stroke 135cc liquid-cooled engine, Honda Wave 125 X Air Cooled, 4 Cycle Engine Overhead Camshaft (OHC) and Suzuki Shogun RR 4 stroke air cooled Single Overhead Camshaft (SOHC). The modification is applied to the engine through the simulation and tuning of Capacitor Discharge Ignition (CDI).
Climate remains an important driver of post-European vegetation change in the eastern United States
Neil Pederson,; Anthony W. D’Amato,; James M. Dyer,; Foster, David R.; Goldblum, David; Hart, Justin L.; Hessl, Amy E.; Iverson, Louis R.; Jackson, Stephen T.; Martin-Benito, Dario; McCarthy, Brian C.; McEwan, Ryan W.; Mladenoff, David J.; Parker, Albert J.; Shuman, Bryan; Williams, John W.
2014-01-01
The influence of climate on forest change during the past century in the eastern United States was evaluated in a recent paper (Nowacki & Abrams, 2014) that centers on an increase in ‘highly competitive mesophytic hardwoods’ (Nowacki & Abrams, 2008) and a concomitant decrease in the more xerophytic Quercus species. Nowacki & Abrams (2014) concluded that climate change has not contributed significantly to observed changes in forest composition. However, the authors restrict their focus to a single element of climate: increasing temperature since the end of the Little Ice Age ca. 150 years ago. In their study, species were binned into four classifications (e.g., Acer saccharum – ‘cool-adapted’, Acer rubrum – ‘warm-adapted’) based on average annual temperature within each species range in the United States, reducing the multifaceted character of climate into a single, categorical measure. The broad temperature classes not only veil the many biologically relevant aspects of temperature (e.g., seasonal and extreme temperatures) but they may also mask other influences, both climatic (e.g., moisture sensitivity) and nonclimatic (e.g., competition).
Arndt, J; Deboudt, K; Anderson, A; Blondel, A; Eliet, S; Flament, P; Fourmentin, M; Healy, R M; Savary, V; Setyan, A; Wenger, J C
2016-03-01
The chemical composition of single particles deposited on industrial filters located in three different chimneys of an iron-manganese (Fe-Mn) alloy manufacturing plant have been compared using aerosol time-of-flight mass spectrometry (ATOFMS) and scanning electron microscopy-energy dispersive X-ray spectrometry (SEM-EDX). Very similar types of particles were observed using both analytical techniques. Calcium-containing particles dominated in the firing area of the sintering unit, Mn and/or Al-bearing particles were observed at the cooling area of the sintering unit, while Mn-containing particles were dominant at the smelting unit. SEM-EDX analysis of particles collected downstream of the industrial filters showed that the composition of the particles emitted from the chimneys is very similar to those collected on the filters. ATOFMS analysis of ore samples was also performed to identify particulate emissions that could be generated by wind erosion and manual activities. Specific particle types have been identified for each emission source (chimneys and ore piles) and can be used as tracers for source apportionment of ambient PM measured in the vicinity of the industrial site. Copyright © 2015 Elsevier Ltd. All rights reserved.
A 63 K phase change unit integrating with pulse tube cryocoolers
NASA Astrophysics Data System (ADS)
Chunhui, Kong; Liubiao, Chen; Sixue, Liu; Yuan, Zhou; Junjie, Wang
2017-02-01
This article presents the design and computer model results of an integrated cooler system which consists of a single stage pulse tube cryocooler integrated with a small amount of a phase change material. A cryogenic thermal switch was used to thermally connect the phase change unit to the cold end of the cryocooler. During heat load operation, the cryogenic thermal switch is turned off to avoid vibrations. The phase change unit absorbs heat loads by melting a substance in a constant pressure-temperature-volume process. Once the substance has been melted, the cryogenic thermal turned on, the cryocooler can then refreeze the material. Advantages of this type of cooler are no vibrations during sensor operations; the ability to absorb increased heat loads; potentially longer system lifetime; and a lower mass, volume and cost. A numerical model was constructed from derived thermodynamic relationships for the cooling/heating and freezing/melting processes.
Numerical evaluation of single central jet for turbine disk cooling
NASA Astrophysics Data System (ADS)
Subbaraman, M. R.; Hadid, A. H.; McConnaughey, P. K.
The cooling arrangement of the Space Shuttle Main Engine High Pressure Oxidizer Turbopump (HPOTP) incorporates two jet rings, each of which produces 19 high-velocity coolant jets. At some operating conditions, the frequency of excitation associated with the 19 jets coincides with the natural frequency of the turbine blades, contributing to fatigue cracking of blade shanks. In this paper, an alternate turbine disk cooling arrangement, applicable to disk faces of zero hub radius, is evaluated, which consists of a single coolant jet impinging at the center of the turbine disk. Results of the CFD analysis show that replacing the jet ring with a single central coolant jet in the HPOTP leads to an acceptable thermal environment at the disk rim. Based on the predictions of flow and temperature fields for operating conditions, the single central jet cooling system was recommended for implementation into the development program of the Technology Test Bed Engine at NASA Marshall Space Flight Center.
NASA Technical Reports Server (NTRS)
Gerrish, Harold C; Tessmann, Arthur M
1935-01-01
The relation of hydrogen and methane to carbon monoxide in the exhaust gases from internal-combustion engines operating on standard-grade aviation gasoline, fighting-grade aviation gasoline, hydrogenated safety fuel, laboratory diesel fuel, and auto diesel fuel was determined by analysis of the exhaust gases. Two liquid-cooled single-cylinder spark-ignition, one 9-cylinder radial air-cooled spark-ignition, and two liquid-cooled single-cylinder compression-ignition engines were used.
Startup of air-cooled condensers and dry cooling towers at low temperatures of the cooling air
NASA Astrophysics Data System (ADS)
Milman, O. O.; Ptakhin, A. V.; Kondratev, A. V.; Shifrin, B. A.; Yankov, G. G.
2016-05-01
The problems of startup and performance of air-cooled condensers (ACC) and dry cooling towers (DCT) at low cooling air temperatures are considered. Effects of the startup of the ACC at sub-zero temperatures are described. Different options of the ACC heating up are analyzed, and examples of existing technologies are presented (electric heating, heating up with hot air or steam, and internal and external heating). The use of additional heat exchanging sections, steam tracers, in the DCT design is described. The need for high power in cases of electric heating and heating up with hot air is noted. An experimental stand for research and testing of the ACC startup at low temperatures is described. The design of the three-pass ACC unit is given, and its advantages over classical single-pass design at low temperatures are listed. The formation of ice plugs inside the heat exchanging tubes during the start-up of ACC and DCT at low cooling air temperatures is analyzed. Experimental data on the effect of the steam flow rate, steam nozzle distance from the heat-exchange surface, and their orientation in space on the metal temperature were collected, and test results are analyzed. It is noted that the surface temperature at the end of the heat up is almost independent from its initial temperature. Recommendations for the safe start-up of ACCs and DCTs are given. The heating flow necessary to sufficiently heat up heat-exchange surfaces of ACCs and DCTs for the safe startup is estimated. The technology and the process of the heat up of the ACC with the heating steam external supply are described by the example of the startup of the full-scale section of the ACC at sub-zero temperatures of the cooling air, and the advantages of the proposed start-up technology are confirmed.
24 CFR 3280.714 - Appliances, cooling.
Code of Federal Regulations, 2014 CFR
2014-04-01
... any air conditioning or comfort-cooling system installed in a manufactured home shall employ a type of...) Every air conditioning unit or a combination air conditioning and heating unit shall be listed or... installed in accordance with the terms of its listing. (1) Mechanical air conditioners shall be rated in...
Duncan, G H; Bushnell, M C; Oliveras, J L; Bastrash, N; Tremblay, N
1993-11-01
1. The present study evaluates the necessity of the ventroposterior medial thalamic nucleus (VPM) for discrimination of the intensity of noxious heating, innocuous cooling, and innocuous tactile (airpuff) stimulation of the maxillary skin. 2. Two rhesus monkeys were trained to detect small differences (< 1.0 degrees C) in the intensity of noxious heat (near 46 degrees C) and innocuous cold (near 30 degrees C) as well as differences in the force of an airpuff applied to the skin over the maxilla. As a control the monkeys also detected small differences in the intensity of a white light. Lidocaine hydrochloride (2%) was microinjected into regions of thalamus where single-unit recordings had identified neuronal responses to the noxious heating and/or cooling stimuli. The effectiveness of the anesthetic blockade was monitored by multiunit recordings using microelectrodes positioned 1-3 mm from the orifice of the injection cannula. The monkey's ability to detect near-threshold changes in stimulus intensity was compared before and after each injection. 3. During six experimental sessions, single injections of 1-4 microliters lidocaine near the dorsomedial border of VPM did not significantly alter the monkey's ability to detect small changes in the intensity of noxious heat, cool, airpuff, or visual stimuli despite neurophysiological evidence that spontaneous neuronal activity was blocked within parts of VPM. 4. During three experiments, dual simultaneous microinjections of lidocaine (delivered through 2 microcannulae separated by approximately 1 mm) resulted in profound deficits in noxious heat discrimination, with lesser deficits in cool and airpuff discrimination; visual discrimination was never altered. Monitoring of adjacent microelectrodes revealed that although activity ventral to the injection sites was blocked, activity in medial thalamic nuclei, implicated in nociceptive processing, was probably not altered by these injections. 5. These data suggest that VPM is important for the perception of noxious and innocuous thermal stimuli as well as for the perception of tactile stimuli. However, considering the ineffectiveness of small single microinjections of lidocaine, it appears that some critical proportion of VPM must be inactivated to disrupt thermal or tactile discrimination, possibly because of overlapping receptive field properties of neurons in different areas of the nucleus.
NASA Astrophysics Data System (ADS)
Khalatov, A. A.; Petliak, O. O.; Severin, S. D.; Panchenko, N. A.
2018-03-01
The purpose of this work is a comparative study of the physical structure and film cooling efficiency of the single array of inclined holes, placed in triangular dimples and in a trench. The software package ANSYS CFX 17.0 was used along with RANS SST turbulence model. Calculations were made in a wide range of the blowing ratio ranging from 0.5 to 2.0. Results of modeling have shown high efficiency of triangular film cooling configuration. At m ≥ 1.5, the triangular configuration is comparable with the trench configuration in terms of the film cooling efficiency.
64. INTERIOR VIEW OF THE CARBIDE COOLING SHED. VIEW IS ...
64. INTERIOR VIEW OF THE CARBIDE COOLING SHED. VIEW IS SHOWING CALCIUM CARBIDE IN COOLING CARS ON THE FLOOR. DECEMBER 26, 1918. - United States Nitrate Plant No. 2, Reservation Road, Muscle Shoals, Muscle Shoals, Colbert County, AL
Effects of N and B on continuous cooling transformation diagrams of Mo-V-Ti micro-alloyed steels
NASA Astrophysics Data System (ADS)
Yuhui, Wang; Bo, Liao; Ligang, Liu; Xianfeng, Li; Hang, Su; Caifu, Yang; Qingfeng, Wang
2012-05-01
Effects of the single addition of nitrogen (N) and boron (B) and the combined addition of N and B on continuous cooling transformation (CCT) diagrams and properties of the three Mo-V-Ti micro-alloyed steels were investigated by means of a combined method of dilatometry and metallography. Microstructures observed in continuous cooled specimens were composed of pearlite (P), quasi-polygonal ferrite (QPF), granular bainite (GB), acicular ferrite (AF), lath-like bainite (LB) and martensite (M) depending on the cooling rates and transformation temperatures. Single addition of 12 ppm B effectively reduced the formation of QPF and broadened the cooling rate region for LB and M. Added N makes the action of B invalid and the QPF region was prominently broadened, and even though the cooling rate is higher than 50°C s-1, it cannot obtain full bainite.
NASA Astrophysics Data System (ADS)
Mekanik, Abolghasem; Soleimani, Mohsen
2007-11-01
Wind effect on natural draught cooling towers has a very complex physics. The fluid flow and temperature distribution around and in a single and two adjacent (tandem and side by side) dry-cooling towers under cross wind are studied numerically in the present work. Cross-wind can significantly reduce cooling efficiency of natural-draft dry-cooling towers, and the adjacent towers can affect the cooling efficiency of both. In this paper we will present a complex computational model involving more than 750,000 finite volume cells under precisely defined boundary condition. Since the flow is turbulent, the standard k-ɛ turbulence model is used. The numerical results are used to estimate the heat transfer between radiators of the tower and air surrounding it. The numerical simulation explained the main reason for decline of the thermo-dynamical performance of dry-cooling tower under cross wind. In this paper, the incompressible fluid flow is simulated, and the flow is assumed steady and three-dimensional.
Sub-cooled liquid nitrogen cryogenic system with neon turbo-refrigerator for HTS power equipment
NASA Astrophysics Data System (ADS)
Yoshida, S.; Hirai, H.; Nara, N.; Ozaki, S.; Hirokawa, M.; Eguchi, T.; Hayashi, H.; Iwakuma, M.; Shiohara, Y.
2014-01-01
We developed a prototype sub-cooled liquid nitrogen (LN) circulation system for HTS power equipment. The system consists of a neon turbo-Brayton refrigerator with a LN sub-cooler and LN circulation pump unit. The neon refrigerator has more than 2 kW cooling power at 65 K. The LN sub-cooler is a plate-fin type heat exchanger and is installed in a refrigerator cold box. In order to carry out the system performance tests, a dummy cryostat having an electric heater was set instead of a HTS power equipment. Sub-cooled LN is delivered into the sub-cooler by the LN circulation pump and cooled within it. After the sub-cooler, sub-cooled LN goes out from the cold box to the dummy cryostat, and comes back to the pump unit. The system can control an outlet sub-cooled LN temperature by adjusting refrigerator cooling power. The refrigerator cooling power is automatically controlled by the turbo-compressor rotational speed. In the performance tests, we increased an electric heater power from 200 W to 1300 W abruptly. We confirmed the temperature fluctuation was about ±1 K. We show the cryogenic system details and performance test results in this paper.
X-Ray spectroscopy of cooling flows
NASA Technical Reports Server (NTRS)
Prestwich, Andrea
1996-01-01
Cooling flows in clusters of galaxies occur when the cooling time of the gas is shorter than the age of the cluster; material cools and falls to the center of the cluster potential. Evidence for short X-ray cooling times comes from imaging studies of clusters and X-ray spectroscopy of a few bright clusters. Because the mass accretion rate can be high (a few 100 solar mass units/year) the mass of material accumulated over the lifetime of a cluster can be as high as 10(exp 12) solar mass units. However, there is little evidence for this material at other wavelengths, and the final fate of the accretion material is unknown. X-ray spectra obtained with the Einstein SSS show evidence for absorption; if confirmed this result would imply that the accretion material is in the form of cool dense clouds. However ice on the SSS make these data difficult to interpret. We obtained ASCA spectra of the cooling flow cluster Abell 85. Our primary goals were to search for multi-temperature components that may be indicative of cool gas; search for temperature gradients across the cluster; and look for excess absorption in the cooling region.
Solar heating and cooling system design and development
NASA Technical Reports Server (NTRS)
1978-01-01
The development of eight prototype solar heating and combined heating and cooling systems is reported. Manufacture, test, installation, maintenance, problem resolution, and monitoring the operation of prototype systems is included. Heating and cooling equipment for single family residential and commercial applications and eight operational test sites (four heating and four heating and cooling) is described.
Residual life assessment of the SSME/ATD HPOTP turnaround duct (TAD)
NASA Technical Reports Server (NTRS)
Gross, R. Steven
1996-01-01
This paper is concerned with the prediction of the low cycle thermal fatigue behavior of a component in a developmental (ATD) high pressure liquid oxygen turbopump (HPOTP) for the Space Shuttle Main Engine (SSME). This component is called the Turnaround Duct (TAD). The TAD is a complex single piece casting of MAR-M-247 material. Its function is to turn the hot turbine exhaust gas (1200 F hydrogen rich gas steam) such that it can exhaust radially out of the turbopump. In very simple terms, the TAD consists of two rings connected axially by 22 hollow airfoil shaped struts with the turning vanes placed at the top, middle, and bottom of each strut. The TAD is attached to the other components of the pump via bolts passing through 14 of the 22 struts. Of the remaining 8 struts, four are equally spaced (90 deg interval) and containing a cooling tube through which liquid hydrogen passes on its way to cool the shaft bearing assemblies. The remaining 4 struts are empty. One of the pump units in the certification test series was destructively examined after 22 test firings. Substantial axial cracking was found in two of the struts which contain cooling tubes. None of the other 20 struts showed any sign of internal cracking. This unusual low cycle thermal fatigue behavior within the two cooling tube struts is the focus of this study.
1170 MW/sub t/ HTGR steamer cogeneration plant: design and cost study
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
A conceptual design and cost study is presented for intermediate size high temperature gas-cooled reactor (HTGR) for industrial energy applications performed by United Engineers and Constructors Inc., (UE and C) and The General Atomic Company (GAC). The study is part of a program at ORNL and has the objective to provide support in the evaluation of the technical and economic feasibility of a single unit 1170 MW/sub t/ HTGR steam cycle cogeneration plant (referred to as the Steamer plant) for the production of industrial process energy. Inherent in the achievement of this objective, it was essential to perform a numbermore » of basic tasks such as the development of plant concept, capital cost estimate, project schedule and annual operation and maintenance (O and M) cost.« less
Thermal-hydraulics modeling for prototype testing of the W7-X high heat flux scraper element
Clark, Emily; Lumsdaine, Arnold; Boscary, Jean; ...
2017-07-28
The long-pulse operation of the Wendelstein 7-X (W7-X) stellarator experiment is scheduled to begin in 2020. This operational phase will be equipped with water-cooled plasma facing components to allow for longer pulse durations. Certain simulated plasma scenarios have been shown to produce heat fluxes that surpass the technological limits on the edges of the divertor target elements during steady-state operation. In order to reduce the heat load on the target elements, the addition of a “scraper element” (SE) is under investigation. The SE is composed of 24 water-cooled carbon fiber reinforced carbon composite monoblock units. Multiple full-scale prototypes have beenmore » tested in the GLADIS high heat flux test facility. Previous computational studies revealed discrepancies between the simulations and experimental measurements. In this work, single-phase thermal-hydraulics modeling was performed in ANSYS CFX to identify potential causes for such discrepancies. Possible explanations investigated were the effects of a non-uniform thermal contact resistance and a potential misalignment of the monoblock fibers. And while the difference between the experimental and computational results was not resolved by a non-uniform thermal contact resistance, the computational results provided insight into the potential performance of a W7-X monoblock unit. Circumferential temperature distributions highlighted the expected boiling regions of such a unit. Finally, simulations revealed that modest angles of fiber misalignment in the monoblocks result in asymmetries at the unit edges and provide temperature differences similar to the experimental results.« less
Thermal-hydraulics modeling for prototype testing of the W7-X high heat flux scraper element
DOE Office of Scientific and Technical Information (OSTI.GOV)
Clark, Emily; Lumsdaine, Arnold; Boscary, Jean
The long-pulse operation of the Wendelstein 7-X (W7-X) stellarator experiment is scheduled to begin in 2020. This operational phase will be equipped with water-cooled plasma facing components to allow for longer pulse durations. Certain simulated plasma scenarios have been shown to produce heat fluxes that surpass the technological limits on the edges of the divertor target elements during steady-state operation. In order to reduce the heat load on the target elements, the addition of a “scraper element” (SE) is under investigation. The SE is composed of 24 water-cooled carbon fiber reinforced carbon composite monoblock units. Multiple full-scale prototypes have beenmore » tested in the GLADIS high heat flux test facility. Previous computational studies revealed discrepancies between the simulations and experimental measurements. In this work, single-phase thermal-hydraulics modeling was performed in ANSYS CFX to identify potential causes for such discrepancies. Possible explanations investigated were the effects of a non-uniform thermal contact resistance and a potential misalignment of the monoblock fibers. And while the difference between the experimental and computational results was not resolved by a non-uniform thermal contact resistance, the computational results provided insight into the potential performance of a W7-X monoblock unit. Circumferential temperature distributions highlighted the expected boiling regions of such a unit. Finally, simulations revealed that modest angles of fiber misalignment in the monoblocks result in asymmetries at the unit edges and provide temperature differences similar to the experimental results.« less
Lapierre, Pascal; Nazarian, Elizabeth; Zhu, Yan; Wroblewski, Danielle; Saylors, Amy; Passaretti, Teresa; Hughes, Scott; Tran, Anthony; Lin, Ying; Kornblum, John; Morrison, Shatavia S; Mercante, Jeffrey W; Fitzhenry, Robert; Weiss, Don; Raphael, Brian H; Varma, Jay K; Zucker, Howard A; Rakeman, Jennifer L; Musser, Kimberlee A
2017-11-01
During the summer of 2015, New York, New York, USA, had one of the largest and deadliest outbreaks of Legionnaires' disease in the history of the United States. A total of 138 cases and 16 deaths were linked to a single cooling tower in the South Bronx. Analysis of environmental samples and clinical isolates showed that sporadic cases of legionellosis before, during, and after the outbreak could be traced to a slowly evolving, single-ancestor strain. Detection of an ostensibly virulent Legionella strain endemic to the Bronx community suggests potential risk for future cases of legionellosis in the area. The genetic homogeneity of the Legionella population in this area might complicate investigations and interpretations of future outbreaks of Legionnaires' disease.
Nazarian, Elizabeth; Zhu, Yan; Wroblewski, Danielle; Saylors, Amy; Passaretti, Teresa; Hughes, Scott; Tran, Anthony; Lin, Ying; Kornblum, John; Morrison, Shatavia S.; Mercante, Jeffrey W.; Fitzhenry, Robert; Weiss, Don; Raphael, Brian H.; Varma, Jay K.; Zucker, Howard A.; Rakeman, Jennifer L.; Musser, Kimberlee A.
2017-01-01
During the summer of 2015, New York, New York, USA, had one of the largest and deadliest outbreaks of Legionnaires’ disease in the history of the United States. A total of 138 cases and 16 deaths were linked to a single cooling tower in the South Bronx. Analysis of environmental samples and clinical isolates showed that sporadic cases of legionellosis before, during, and after the outbreak could be traced to a slowly evolving, single-ancestor strain. Detection of an ostensibly virulent Legionella strain endemic to the Bronx community suggests potential risk for future cases of legionellosis in the area. The genetic homogeneity of the Legionella population in this area might complicate investigations and interpretations of future outbreaks of Legionnaires’ disease. PMID:29047425
NASA Astrophysics Data System (ADS)
Lenka, Maheswata; Sarkar, Debasis
2018-03-01
This work investigates the effect of internal seeding and an initial cooling/heating cycle on the final crystal size distribution (CSD) during a combined cooling/antisolvent crystallization of L-asparagine monohydrate from it's aqueous solution using isopropyl-alcohol as antisolvent. Internal seeds were generated by one-pot addition of various amounts of antisolvent to the crystallizer. It was then followed by a cooling/heating cycle to dissolve the fines produced and thus obtain a suitable initial seed. A combined cooling/antisolvent crystallization was then followed by employing a linear cooling profile with simultaneous addition of antisolvent with a constant mass flow rate to promote the growth of the internally generated seeds. The amount of initial antisolvent influences the characteristics of the internal seeds generated and the effect of initial amount of antisolvent on the final CSD is investigated. It was found that the introduction of a single cooling/heating cycle significantly improves the reproducibility of final CSD as well as the mean size. Overall, the study indicates that the application of internal seeding with a single cooling/heating cycle for fines dissolution is an effective technique to tailor crystal size distribution.
System for cooling hybrid vehicle electronics, method for cooling hybrid vehicle electronics
France, David M.; Yu, Wenhua; Singh, Dileep; Zhao, Weihuan
2017-11-21
The invention provides a single radiator cooling system for use in hybrid electric vehicles, the system comprising a surface in thermal communication with electronics, and subcooled boiling fluid contacting the surface. The invention also provides a single radiator method for simultaneously cooling electronics and an internal combustion engine in a hybrid electric vehicle, the method comprising separating a coolant fluid into a first portion and a second portion; directing the first portion to the electronics and the second portion to the internal combustion engine for a time sufficient to maintain the temperature of the electronics at or below 175.degree. C.; combining the first and second portion to reestablish the coolant fluid; and treating the reestablished coolant fluid to the single radiator for a time sufficient to decrease the temperature of the reestablished coolant fluid to the temperature it had before separation.
The Water-Use Implications of a Changing Power Sector
NASA Astrophysics Data System (ADS)
Peer, R.; Sanders, K.
2016-12-01
Changing policies, declining natural gas prices due to shale production and, growing pressure for cleaner energy sources are causing significant shifts in the fuels and technologies utilized for US electricity generation. These shifts have already impacted the volumes of water required for cooling thermal power plants, imposing consequences for watersheds that have yet to be quantified. This research investigates how these regulatory, economic, and socially-driven changes in the power sector have impacted cooling water usage across the US, which currently represents nearly half of US water withdrawals. This study uses plant-specific fuel consumption, generation, and cooling water data to assess water usage trends in the power sector from 2008 to 2014 across HUC-8 hydrologic units. Over this period, transitions from steam-cycle coal and nuclear units towards combined-cycle natural gas units and renewables, as well as transitions from once-through cooling towards wet recirculating tower and dry cooling systems resulted in large shifts in water usage. Trends towards non-traditional cooling water sources such as recycled water reduced freshwater consumption in some watersheds. Although US cooling water withdrawals and consumption increased from 2008 to 2014 largely due to electricity demand growth, the average water withdrawn and consumed per unit of electricity generated decreased and remained similar in magnitude, respectively. Changes at the watershed scale were not uniform, with some experiencing significant water use reductions and environmental benefits, especially due to coal-fired power plant retirements. Results highlight the importance of evaluating both water withdrawals and consumption at local spatial scales, as these shifts have varying consequences on water availability and quality for downstream users and ecosystems. This analysis underscores the importance of prioritizing local water security in global climate change adaptation and mitigation efforts.
Triple-effect absorption chiller cycle: A step beyond double-effect cycles
DOE Office of Scientific and Technical Information (OSTI.GOV)
DeVault, R.C.
1990-01-01
Many advanced'' absorption cycles have been proposed during the current century. Of the hundreds of absorption cycles which have been patented throughout the world, all commercially manufactured products for air conditioning buildings have been variations of just two basic absorption cycles: single-effect and condenser-coupled double-effect cycles. The relatively low cooling coefficients of performance (COPs) inherent in single-effect and double-effect cycles limits the economic applicability of absorption air conditioners (chillers) in the United States. A triple-effect absorption chiller cycle is discussed. This cycle uses two condensers and two absorbers to achieve the triple effect.'' Depending on the absorption fluids selected, thismore » triple-effect cycle is predicted to improve cooling COPs by 18% to 60% compared with the equivalent double-effect cycle. This performance improvement is obtained without increasing the total amount of heat-transfer surface area needed for the heat exchangers. A comparison between the calculated performances of a double-effect cycle and a triple-effect cycle (both using ammonia-water (NH{sub 3}/H{sub 2}O) as the absorption fluid pair) is presented. The triple-effect cycle is predicted to have an 18% higher cooling COP (1.41 compared with 1.2 for a double-effect), lower pressure (47.70 atm (701 psi) instead of 68.05 atm (1000 psi)), significantly reduced pumping power (less than one-half that of the double-effect cycle), and potentially lower construction cost (33% less total heat exchange needed). Practical implications for this triple-effect cycle are discussed. 16 refs., 5 figs., 1 tab.« less
1993-04-16
Kentucky long rifle is an F-15E Strike Eagle with laser -guided munitions). Aerospace power offers the ability for the United States to intervene with...glowing vacuum tubes might overshadow a single, cool microchip in their mids The Gulf War ushered in the era of the very small, very important target...precision, on making it better and better. Use the microchip as the role model. -Focus on forces and ideas which can execute rapidly, and with the minimum of
Energy Supply Alternatives for Picatinny Arsenal, NJ
1992-09-01
condensation unit. The generator is a 3- phase, 60 cycle, synchronous, air -cooled type with brushless exciters. The generator’s voltage is 13.8 kV and rated at...60 cycle, synchronous, air -cooled type with brushless exciters. The generator’s voltage is 13.8 kV and rated at 150 MVA with a 0.85 Power Factor...condensation unit. The generator is a 3- phase, 60 cycle, synchronous, air -cooled type with brushless exciters. The generator’s voltage is 13.8 kV and rated
Cooling systems and hybrid A/C systems using an electromagnetic radiation-absorbing complex
Halas, Nancy J.; Nordlander, Peter; Neumann, Oara
2015-05-19
A method for powering a cooling unit. The method including applying electromagnetic (EM) radiation to a complex, where the complex absorbs the EM radiation to generate heat, transforming, using the heat generated by the complex, a fluid to vapor, and sending the vapor from the vessel to a turbine coupled to a generator by a shaft, where the vapor causes the turbine to rotate, which turns the shaft and causes the generator to generate the electric power, wherein the electric powers supplements the power needed to power the cooling unit
ERIC Educational Resources Information Center
Minnesota State Dept. of Education, St. Paul. Div. of Vocational and Technical Education.
THIS MODULE OF A 30-MODULE COURSE IS DESIGNED TO DEVELOP AN UNDERSTANDING OF THE OPERATION AND MAINTENANCE OF THE DIESEL ENGINE COOLING SYSTEM AND TO PROVIDE A DESCRIPTION OF HEAVY TIRES AND WHEELS USED ON DIESEL POWERED VEHICLES. TOPICS ARE (1) THEORY OF THE COOLING SYSTEM, (2) COOLING SYSTEM COMPONENTS, (3) MAINTENANCE TIPS (COOLING SYSTEM), (4)…
Frontiers in Laser Cooling, Single-Molecule Biophysics, and Energy Science: A Talk from Eric Cornell
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cornell, Eric
2008-08-30
Eric Cornell presents a talk at Frontiers in Laser Cooling, Single-Molecule Biophysics and Energy Science, a scientific symposium honoring Steve Chu, director of Lawrence Berkeley National Laboratory and recipient of the 1997 Nobel Prize in Physics. The symposium was held August 30, 2008 in Berkeley.
Frontiers in Laser Cooling, Single-Molecule Biophysics, and Energy Science: A Talk from Kurt Gibble
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gibble, Kurt
2008-08-30
Kurt Gibble presents a talk at Frontiers in Laser Cooling, Single-Molecule Biophysics and Energy Science, a scientific symposium honoring Steve Chu, director of Lawrence Berkeley National Laboratory and recipient of the 1997 Nobel Prize in Physics. The symposium was held August 30, 2008 in Berkeley.
Frontiers in Laser Cooling, Single-Molecule Biophysics, and Energy Science: A Talk from Jay Keasling
DOE Office of Scientific and Technical Information (OSTI.GOV)
Keasling, Jay
2008-08-30
Jay Keasling presents a talk at Frontiers in Laser Cooling, Single-Molecule Biophysics and Energy Science, a scientific symposium honoring Steve Chu, director of Lawrence Berkeley National Laboratory and recipient of the 1997 Nobel Prize in Physics. The symposium was held August 30, 2008 in Berkeley.
Frontiers in Laser Cooling, Single-Molecule Biophysics, and Enrgy Science: A Talk by Carl Wieman
Wieman, Carl
2017-12-09
Carl Wieman presents a talk at Frontiers in Laser Cooling, Single-Molecule Biophysics and Energy Science, a scientific symposium honoring Steve Chu, director of Lawrence Berkeley National Laboratory and recipient of the 1997 Nobel Prize in Physics. The symposium was held August 30, 2008 in Berkeley.
Frontiers in Laser Cooling, Single-Molecule Biophysics, and Energy Science: A Talk from Eric Cornell
Cornell, Eric
2018-02-05
Eric Cornell presents a talk at Frontiers in Laser Cooling, Single-Molecule Biophysics and Energy Science, a scientific symposium honoring Steve Chu, director of Lawrence Berkeley National Laboratory and recipient of the 1997 Nobel Prize in Physics. The symposium was held August 30, 2008 in Berkeley.
Frontiers in Laser Cooling, Single-Molecule Biophysics, and Energy Science: A Talk from Jay Keasling
Keasling, Jay
2018-02-14
Jay Keasling presents a talk at Frontiers in Laser Cooling, Single-Molecule Biophysics and Energy Science, a scientific symposium honoring Steve Chu, director of Lawrence Berkeley National Laboratory and recipient of the 1997 Nobel Prize in Physics. The symposium was held August 30, 2008 in Berkeley.
Frontiers in Laser Cooling, Single-Molecule Biophysics, and Enrgy Science: A Talk by Carl Wieman
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wieman, Carl
Carl Wieman presents a talk at Frontiers in Laser Cooling, Single-Molecule Biophysics and Energy Science, a scientific symposium honoring Steve Chu, director of Lawrence Berkeley National Laboratory and recipient of the 1997 Nobel Prize in Physics. The symposium was held August 30, 2008 in Berkeley.
Frontiers in Laser Cooling, Single-Molecule Biophysics, and Energy Science: A Talk from Kurt Gibble
Gibble, Kurt
2018-02-05
Kurt Gibble presents a talk at Frontiers in Laser Cooling, Single-Molecule Biophysics and Energy Science, a scientific symposium honoring Steve Chu, director of Lawrence Berkeley National Laboratory and recipient of the 1997 Nobel Prize in Physics. The symposium was held August 30, 2008 in Berkeley.
NASA Astrophysics Data System (ADS)
Fratoni, Massimiliano
This study investigated the neutronic characteristics of the Pebble Bed Advanced High Temperature Reactor (PB-AHTR), a novel nuclear reactor concept that combines liquid salt (7LiF-BeF2---flibe) cooling and TRISO coated-particle fuel technology. The use of flibe enables operation at high power density and atmospheric pressure and improves passive decay-heat removal capabilities, but flibe, unlike conventional helium coolant, is not transparent to neutrons. The flibe occupies 40% of the PB-AHTR core volume and absorbs ˜8% of the neutrons, but also acts as an effective neutron moderator. Two novel methodologies were developed for calculating the time dependent and equilibrium core composition: (1) a simplified single pebble model that is relatively fast; (2) a full 3D core model that is accurate and flexible but computationally intensive. A parametric analysis was performed spanning a wide range of fuel kernel diameters and graphite-to-heavy metal atom ratios to determine the attainable burnup and reactivity coefficients. Using 10% enriched uranium ˜130 GWd/tHM burnup was found to be attainable, when the graphite-to-heavy metal atom ratio (C/HM) is in the range of 300 to 400. At this or smaller C/HM ratio all reactivity coefficients examined---coolant temperature, coolant small and full void, fuel temperature, and moderator temperature, were found to be negative. The PB-AHTR performance was compared to that of alternative options for HTRs, including the helium-cooled pebble-bed reactor and prismatic fuel reactors, both gas-cooled and flibe-cooled. The attainable burnup of all designs was found to be similar. The PB-AHTR generates at least 30% more energy per pebble than the He-cooled pebble-bed reactor. Compared to LWRs the PB-AHTR requires 30% less natural uranium and 20% less separative work per unit of electricity generated. For deep burn TRU fuel made from recycled LWR spent fuel, it was found that in a single pass through the core ˜66% of the TRU can be transmuted; this burnup is slightly superior to that attainable in helium-cooled reactors. A preliminary analysis of the modular variant for the PB-AHTR investigated the triple heterogeneity of this design and determined its performance characteristics.
24 CFR 3280.714 - Appliances, cooling.
Code of Federal Regulations, 2013 CFR
2013-04-01
... refrigerating systems serving any air conditioning or comfort-cooling system installed in a manufactured home... Systems § 3280.714 Appliances, cooling. (a) Every air conditioning unit or a combination air conditioning... Conditioning and Air Source Unitary Heat Pump Equipment and certified by ARI or other nationally recognized...
24 CFR 3280.714 - Appliances, cooling.
Code of Federal Regulations, 2012 CFR
2012-04-01
... refrigerating systems serving any air conditioning or comfort-cooling system installed in a manufactured home... Systems § 3280.714 Appliances, cooling. (a) Every air conditioning unit or a combination air conditioning... Conditioning and Air Source Unitary Heat Pump Equipment and certified by ARI or other nationally recognized...
NASA Technical Reports Server (NTRS)
Makinen, Janice V.; Anchondo, Ian; Bue, Grant C.; Campbell, Colin; Colunga, Aaron
2013-01-01
Development of the Advanced Extravehicular Mobility Unit (AEMU) portable life support subsystem (PLSS) is currently under way at NASA Johnson Space Center. The AEMU PLSS features a new evaporative cooling system, the reduced volume prototype (RVP) spacesuit water membrane evaporator (SWME). The RVP SWME is the third generation of hollow fiber SWME hardware. Like its predecessors, RVP SWME provides nominal crew member and electronics cooling by flowing water through porous hollow fibers. Water vapor escapes through the hollow fiber pores, thereby cooling the liquid water that remains inside of the fibers. This cooled water is then recirculated to remove heat from the crew member and PLSS electronics. Major design improvements, including a 36% reduction in volume, reduced weight, and a more flight-like backpressure valve, facilitate the packaging of RVP SWME in the AEMU PLSS envelope. The development of these evaporative cooling systems will contribute to a more robust and comprehensive AEMU PLSS.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-16
...'') imported by Valeo, Inc., Valeo Engine Cooling Inc., and Valeo Climate Control Corp. (collectively, ``Valeo..., Inc., and Valeo Climate Control Corp. v. United States, Court No. 12-00381 (CIT February 13, 2013).\\2... Remand, Valeo, Inc., Valeo Engine Cooling, Inc., and Valeo Climate Control Corp. v. United States, Court...
Development of a linear compressor for compact 2 K Gifford- McMahon cryocoolers
NASA Astrophysics Data System (ADS)
Hiratsuka, Y.
2015-12-01
Recently, a new, compact Gifford-McMahon (GM) cryocooler for cooling superconducting single photon detectors (SSPD) has been developed at Sumitomo Heavy Industries, Ltd. (SHI) [1, 2]. The objective is to reduce the total height of the expander by 33% relative to the existing RDK-101 GM expander and to reduce the total volume of the compressor unit by 50% relative to the existing CNA-11 compressor. In addition, considering the targeted cooling application, we set the design temperature targets of the first and the second stages to 1 W and 20 mW of heat load at 60 K and 2.3 K, respectively. Although optimization of the internal components is one way to miniaturize the volume of the compressor unit, major design changes are required because the volume of the adsorber and the oil separator is almost the same as the volume of the compressor capsule. Thus, one approach is to develop a non-lubricated compressor, such as a valved linear compressor. An experimental unit of a valved linear compressor was designed and built, and preliminary experiments were conducted. Under no-load condition, a low temperature of 2.19 K has been achieved. With 1 W and 14 mW heat load, the temperature is 48 K at the first stage and 2.3 K at the second stage, with an input power of about 1.2 KW. The detailed experimental results will be discussed in this paper.
NASA Astrophysics Data System (ADS)
Sharif, Hafiz Zafar; Leman, A. M.; Muthuraman, S.; Salleh, Mohd Najib Mohd; Zakaria, Supaat
2017-09-01
Combined heating, cooling, and power is also known as Tri-generation. Tri-generation system can provide power, hot water, space heating and air -conditioning from single source of energy. The objective of this study is to propose a method to evaluate the characteristic and performance of a single stage lithium bromide-water (LiBr-H2O) absorption machine operated with waste thermal energy of internal combustion engine which is integral part of trigeneration system. Correlations for computer sensitivity analysis are developed in data fit software for (P-T-X), (H-T-X), saturated liquid (water), saturated vapor, saturation pressure and crystallization temperature curve of LiBr-H2O Solution. Number of equations were developed with data fit software and exported into excel work sheet for the evaluation of number of parameter concerned with the performance of vapor absorption machine such as co-efficient of performance, concentration of solution, mass flow rate, size of heat exchangers of the unit in relation to the generator, condenser, absorber and evaporator temperatures. Size of vapor absorption machine within its crystallization limits for cooling and heating by waste energy recovered from exhaust gas, and jacket water of internal combustion engine also presented in this study to save the time and cost for the facilities managers who are interested to utilize the waste thermal energy of their buildings or premises for heating and air conditioning applications.
Water-carbon trade-off in China's coal power industry.
Zhang, Chao; Anadon, Laura Diaz; Mo, Hongpin; Zhao, Zhongnan; Liu, Zhu
2014-10-07
The energy sector is increasingly facing water scarcity constraints in many regions around the globe, especially in China, where the unprecedented large-scale construction of coal-fired thermal power plants is taking place in its extremely arid northwest regions. As a response to water scarcity, air-cooled coal power plants have experienced dramatic diffusion in China since the middle 2000s. By the end of 2012, air-cooled coal-fired thermal power plants in China amounted to 112 GW, making up 14% of China's thermal power generation capacity. But the water conservation benefit of air-cooled units is achieved at the cost of lower thermal efficiency and consequently higher carbon emission intensity. We estimate that in 2012 the deployment of air-cooled units contributed an additional 24.3-31.9 million tonnes of CO2 emissions (equivalent to 0.7-1.0% of the total CO2 emissions by China's electric power sector), while saving 832-942 million m(3) of consumptive water use (about 60% of the total annual water use of Beijing) when compared to a scenario with water-cooled plants. Additional CO2 emissions from air-cooled plants largely offset the CO2 emissions reduction benefits from Chinese policies of retiring small and outdated coal plants. This water-carbon trade-off is poised to become even more significant by 2020, as air-cooled units are expected to grow by a factor of 2-260 GW, accounting for 22% of China's total coal-fired power generation capacity.
Kumar, Sunil; Pattanayek, Sudip K; Pereira, Gerald G
2014-01-14
We use molecular dynamics simulations to investigate the arrangement of polymer chains when absorbed onto a long, single-wall carbon nano-tube (SWCNT). We study the conformation and organization of the polymer chains on the SWCNT and their dependence on the tube's diameter and the rate of cooling. We use two types of cooling processes: direct quenching and gradual cooling. The radial density distribution function and bond orientational order parameter are used to characterize the polymer chain structure near the surface. In the direct cooling process, the beads of the polymer chain organize in lamella-like patterns on the surface of the SWCNT with the long axis of the lamella parallel to the axis of the SWCNT. In a stepwise, gradual cooling process, the polymer beads form a helical pattern on the surface of a relatively thick SWCNT, but form a lamella-like pattern on the surface of a very thin SWCNT. We develop a theoretical (free energy) model to explain this difference in pattern structures for the gradual cooling process and also provide a qualitative explanation for the pattern that forms from the direct cooling process.
NASA Astrophysics Data System (ADS)
Wang, Z. L.; Shen, Y. F.; Wang, Z. B.; Wang, J.
2017-08-01
Semi-closed single screw refrigeration compressors (SSRC) are widely used in refrigeration and air conditioning systems owing to the advantages of simple structure, balanced forces on the rotor, high volumetric efficiency and so on. In semi-closed SSRCs, motor is often cooled by suction gas or injected refrigerant liquid. Motor cooling method will changes the suction gas temperature, this to a certain extent, is an important factor influencing the thermal dynamic performance of a compressor. Thus the effects of motor cooling method on the performance of the compressor must be studied. In this paper mathematical models of motor cooling process by using these two methods were established. Influences of motor cooling parameters such as suction gas temperature, suction gas quantity, temperature of the injected refrigerant liquid and quantity of the injected refrigerant liquid on the thermal dynamic performance of the compressor were analyzed. The performances of the compressor using these two kinds of motor cooling methods were compared. The motor cooling capacity of the injected refrigerant liquid is proved to be better than the suction gas. All analysis results obtained can be useful for optimum design of the motor cooling process to improve the efficiency and the energy efficiency of the compressor.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chu, Steve
2008-08-30
Steve Chu, director of Lawrence Berkeley National Laboratory and recipient of the 1997 Nobel Prize, presents a talk at Frontiers in Laser Cooling, Single-Molecule Biophysics and Energy Science, a scientific symposium in his honor. The symposium was held August 30, 2008 in Berkeley.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Holberg, Leo; Mills, Allen
2008-08-30
Leo Holberg and Allen Mills present a talk at Frontiers in Laser Cooling, Single-Molecule Biophysics and Energy Science, a scientific symposium honoring Steve Chu, director of Lawrence Berkeley National Laboratory and recipient of the 1997 Nobel Prize in Physics. The symposium was held August 30, 2008 in Berkeley.
Holberg, Leo; Mills, Allen
2018-05-07
Leo Holberg and Allen Mills present a talk at Frontiers in Laser Cooling, Single-Molecule Biophysics and Energy Science, a scientific symposium honoring Steve Chu, director of Lawrence Berkeley National Laboratory and recipient of the 1997 Nobel Prize in Physics. The symposium was held August 30, 2008 in Berkeley.
NASA Astrophysics Data System (ADS)
Tyapkov, V. F.; Chudakova, I. Yu.; Alekseenko, O. A.
2011-08-01
Ways of improving the water chemistry used in the turbine generator stator's cooling systems at Russian nuclear power plants are considered. Data obtained from operational chemical monitoring of indicators characterizing the quality of cooling water in the turbine generator stator cooling systems of operating power units at nuclear power plants are presented.
Development of a Battery-Free Solar Refrigerator
NASA Technical Reports Server (NTRS)
Ewert, Michael K.; Bergeron, David J., III
2000-01-01
Recent technology developments and a systems engineering design approach have led to the development of a practical battery-free solar refrigerator as a spin-off of NASA's aerospace refrigeration research. Off-grid refrigeration is a good application of solar photovoltaic (PV) power if thermal storage is incorporated and a direct connection is made between the cooling system and the PV panel. This was accomplished by integrating water as a phase-change material into a well insulated refrigerator cabinet and by developing a microprocessor based control system that allows direct connection of a PV panel to a variable speed compressor. This second innovation also allowed peak power-point tracking from the PV panel and elimination of batteries from the system. First a laboratory unit was developed to prove the concept and then a commercial unit was produced and deployed in a field test. The laboratory unit was used to test many different configurations including thermoelectric, Stirling and vapor compression cooling systems. The final configuration used a vapor compression cooling cycle, vacuum insulation, a passive condenser, an integral evaporator/ thermal storage tank, two 77 watt PV panels and the novel controller mentioned above. The system's only moving part was the variable speed BD35 compressor made by Danfoss. The 365 liter cabinet stayed cold with as little as 274 watt-hours per day average PV power. Battery-free testing was conducted for several months with very good results. The amount of thermal storage, size of compressor and power of PV panels connected can all be adjusted to optimize the design for a given application and climate. In the commercial unit, the high cost of the vacuum insulated refrigerator cabinet and the stainless steel thermal storage tank were addressed in an effort to make the technology commercially viable. This unit started with a 142 liter, mass-produced chest freezer cabinet that had the evaporator integrated into its inner walls. Its compressor was replaced with a Danfoss DC compressor slightly larger than the one used in the laboratory unit. The control system was integrated onto a single electronics card and packaged with its starting capacitors. The water for thermal storage was placed behind a liner that was made to fit inside the original factory liner. The original condenser was also augmented with additional surface area to improve performance. PV panels with a total rated power of 180 watts were used. The unit was tested with very successful results in an outside ambient environment, demonstrating its potential for widespread use in many off-grid applications for solar refrigeration.
Preliminary design package for solar heating and cooling systems
NASA Technical Reports Server (NTRS)
1978-01-01
Summarized preliminary design information on activities associated with the development, delivery and support of solar heating and cooling systems is given. These systems are for single family dwellings and commercial applications. The heating/cooling system use a reversible vapor compression heat pump that is driven in the cooling mode by a Rankine power loop, and in the heating mode by a variable speed electric motor. The heating/cooling systems differ from the heating-only systems in the arrangement of the heat pump subsystem and the addition of a cooling tower to provide the heat sink for cooling mode operation.
Tunable metamaterial dual-band terahertz absorber
NASA Astrophysics Data System (ADS)
Luo, C. Y.; Li, Z. Z.; Guo, Z. H.; Yue, J.; Luo, Q.; Yao, G.; Ji, J.; Rao, Y. K.; Li, R. K.; Li, D.; Wang, H. X.; Yao, J. Q.; Ling, F. R.
2015-11-01
We report a design of a temperature controlled tunable dual band terahertz absorber. The compact single unit cell consists of two nested closed square ring resonators and a layer metallic separated by a substrate strontium titanate (STO) dielectric layer. It is found that the absorber has two distinctive absorption peaks at frequencies 0.096 THz and 0.137 THz, whose peaks are attained 97% and 75%. Cooling the absorber from 400 K to 250 K causes about 25% and 27% shift compared to the resonance frequency of room temperature, when we cooling the temperature to 150 K, we could attained both the two tunabilities exceeding 53%. The frequency tunability is owing to the variation of the dielectric constant of the low-temperature co-fired ceramic (LTCC) substrate. The mechanism of the dual band absorber is attributed to the overlapping of dual resonance frequencies, and could be demonstrated by the distributions of the electric field. The method opens up avenues for designing tunable terahertz devices in detection, imaging, and stealth technology.
Fourier Transfrom Ion Cyclotron Resonance Mass Spectrometry at High Magnetic Field
NASA Astrophysics Data System (ADS)
Marshall, Alan G.
1998-03-01
At high magnetic field (9.4 tesla at NHMFL), Fourier transform ion cyclotron resonance mass spectrometry performance improves dramatically: mass resolving power, axialization efficiency, and scan speed (each proportional to B), maximum ion mass, dynamic range, ion trapping period, kinetic energy, and electron self-cooling rate for sympathetic cooling (each proportional to B^2), and ion coalescence tendency (proportional 1/B^2). These advantages may apply singly (e.g., unit mass resolution for proteins of >100,000 Da), or compound (e.g., 10-fold improvement in S/N ratio for 9.4 T vs. 6 T at the same resolving power). Examples range from direct determination of molecular formulas of diesel fuel components by accurate mass measurement (=B10.1 ppm) to protein structure and dynamics probed by H/D exchange. This work was supported by N.S.F. (CHE-93-22824; CHE-94-13008), N.I.H. (GM-31683), Florida State University, and the National High Magnetic Field Laboratory in Tallahassee, FL.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-03
...The U.S. Nuclear Regulatory Commission (NRC or the Commission) is issuing a revision to Regulatory Guide (RG) 1.52, ``Design, Inspection, and Testing Criteria for Air Filtration and Adsorption Units of Post-accident Engineered-Safety-Feature Atmosphere Cleanup Systems in Light-Water-Cooled Nuclear Power Plants.'' This guide applies to the design, inspection, and testing of air filtration and iodine adsorption units of engineered-safety-feature (ESF) atmosphere cleanup systems in light-water-cooled nuclear power plants.
Measured effects of coolant injection on the performance of a film cooled turbine
NASA Technical Reports Server (NTRS)
Mcdonel, J. D.; Eiswerth, J. E.
1977-01-01
Tests have been conducted on a 20-inch diameter single-stage air-cooled turbine designed to evaluate the effects of film cooling air on turbine aerodynamic performance. The present paper reports the results of five test configurations, including two different cooling designs and three combinations of cooled and solid airfoils. A comparison is made of the experimental results with a previously published analytical method of evaluating coolant injection effects on turbine performance.
Piston Temperatures in an Air-Cooled Engine for Various Operating Conditions
NASA Technical Reports Server (NTRS)
Manganiello, Eugene J
1940-01-01
As part of a program for the study of piston cooling, this report presents the results of tests conducted on a single-cylinder, air-cooled, carburetor engine to determine the effect of engine operating conditions on the temperatures at five locations on the piston.
Chen, Shang-ke; Wang, Kui; Liu, Yuhuan; Hu, Xiaopeng
2012-01-01
Feruloyl esterase cleaves the ester linkage formed between ferulic acid and polysaccharides in plant cell walls and thus has wide potential industrial applications. A novel feruloyl esterase (EstF27) identified from a soil metagenomic library was crystallized and a complete data set was collected from a single cooled crystal using an in-house X-ray source. The crystal diffracted to 2.9 Å resolution and belonged to space group P212121, with unit-cell parameters a = 94.35, b = 106.19, c = 188.51 Å, α = β = γ = 90.00°. A Matthews coefficient of 2.55 Å3 Da−1, with a corresponding solvent content of 51.84%, suggested the presence of ten protein subunits in the asymmetric unit. PMID:22750860
Water consumption by nuclear powerplants and some hydrological implications
Giusti, Ennio V.; Meyer, E.L.
1977-01-01
Published data show that estimated water consumption varies with the cooling system adopted, being least in once-through cooling (about 18 cubic feet per second per 1,000 megawatts electrical) and greatest in closed cooling with mechanical draft towers (about 30 cubic feet per second per 1,000 megawatts electrical). When freshwater is used at this magnitude, water-resources economy may be affected in a given region. The critical need for cooling water at all times by the nuclear powerplant industry, coupled with the knowledge that water withdrawal in the basin will generally increase with time and will be at a maximum during low-flow periods, indicates a need for reexamination of the design low flow currently adopted and the methods used to estimate it. The amount of power generated, the name of the cooling water source, and the cooling method adopted for all nuclear powerplants projected to be in operation by 1985 in the United States are tabulated and the estimated annual evaporation at each powerplant site is shown on a map of the conterminous United States. Another map is presented that shows all nuclear powerplants located on river sites as well as stream reaches in the United States where the 7-day, 10-year low flow is at least 300 cubic feet per second or where this amount of flow can be developed with storage. (Woodard-USGS)
High Fidelity Preparation of a Single Atom in Its 2D Center of Mass Ground State
NASA Astrophysics Data System (ADS)
Sompet, Pimonpan; Fung, Yin Hsien; Schwartz, Eyal; Hunter, Matthew D. J.; Phrompao, Jindaratsamee; Andersen, Mikkel F.
2017-04-01
Complete control over quantum states of individual atoms is important for the study of the microscopic world. Here, we present a push button method for high fidelity preparation of a single 85Rb atom in the vibrational ground state of tightly focused optical tweezers. The method combines near-deterministic preparation of a single atom with magnetically-insensitive Raman sideband cooling. We achieve 2D cooling in the radial plane with a ground state population of 0.85, which provides a fidelity of 0.7 for the entire procedure (loading and cooling). The Raman beams couple two sublevels (| F = 3 , m = 0 〉 and | F = 2 , m = 0 〉) that are indifferent to magnetic noise to first order. This leads to long atomic coherence times, and allows us to implement the cooling in an environment where magnetic field fluctuations prohibit previously demonstrated variations. Additionally, we implement the trapping and manipulation of two atoms confined in separate dynamically reconfigurable optical tweezers, to study few-body dynamics.
Provisioning cooling elements for chillerless data centers
Chainer, Timothy J.; Parida, Pritish R.
2016-12-13
Systems and methods for cooling include one or more computing structure, an inter-structure liquid cooling system that includes valves configured to selectively provide liquid coolant to the one or more computing structures; a heat rejection system that includes one or more heat rejection units configured to cool liquid coolant; and one or more liquid-to-liquid heat exchangers that include valves configured to selectively transfer heat from liquid coolant in the inter-structure liquid cooling system to liquid coolant in the heat rejection system. Each computing structure further includes one or more liquid-cooled servers; and an intra-structure liquid cooling system that has valves configured to selectively provide liquid coolant to the one or more liquid-cooled servers.
Fast cooldown coaxial pulse tube microcooler
NASA Astrophysics Data System (ADS)
Nast, T.; Olson, J. R.; Champagne, P.; Roth, E.; Kaldas, G.; Saito, E.; Loung, V.; McCay, B. S.; Kenton, A. C.; Dobbins, C. L.
2016-05-01
We report the development and initial testing of the Lockheed Martin first-article, single-stage, compact, coaxial, Fast Cooldown Pulse Tube Microcryocooler (FC-PTM). The new cryocooler supports cooling requirements for emerging large, high operating temperature (105-150K) infrared focal plane array sensors with nominal cooling loads of ~300 mW @105K @293K ambient. This is a sequel development that builds on our inline and coaxial pulse tube microcryocoolers reported at CEC 20137, ICC188,9, and CEC201510. The new FC-PTM and the prior units all share our long life space technology attributes, which typically have 10 year life requirements1. The new prototype microcryocooler builds on the previous development by incorporating cold head design improvements in two key areas: 1) reduced cool-down time and 2) novel repackaging that greatly reduces envelope. The new coldhead and Dewar were significantly redesigned from the earlier versions in order to achieve a cooldown time of 2-3 minutes-- a projected requirement for tactical applications. A design approach was devised to reduce the cold head length from 115mm to 55mm, while at the same time reducing cooldown time. We present new FC-PTM performance test measurements with comparisons to our previous pulse-tube microcryocooler measurements and design predictions. The FC-PTM exhibits attractive small size, volume, weight, power and cost (SWaP-C) features with sufficient cooling capacity over required ambient conditions that apply to an increasing variety of space and tactical applications.
Intradermal endothelin-1 excites bombesin-responsive superficial dorsal horn neurons in the mouse
Akiyama, T.; Nagamine, M.; Davoodi, A.; Iodi Carstens, M.; Cevikbas, F.; Steinhoff, M.
2015-01-01
Endothelin-1 (ET-1) has been implicated in nonhistaminergic itch. Here we used electrophysiological methods to investigate whether mouse superficial dorsal horn neurons respond to intradermal (id) injection of ET-1 and whether ET-1-sensitive neurons additionally respond to other pruritic and algesic stimuli or spinal superfusion of bombesin, a homolog of gastrin-releasing peptide (GRP) that excites spinal itch-signaling neurons. Single-unit recordings were made from lumbar dorsal horn neurons in pentobarbital-anesthetized C57BL/6 mice. We searched for units that exhibited elevated firing after id injection of ET-1 (1 μg/μl). Responsive units were further tested with mechanical stimuli, bombesin (spinal superfusion, 200 μg·ml−1·min−1), heating, cooling, and additional chemicals [histamine, chloroquine, allyl isothiocyanate (AITC), capsaicin]. Of 40 ET-1-responsive units, 48% responded to brush and pinch [wide dynamic range (WDR)] and 52% to pinch only [high threshold (HT)]. Ninety-three percent responded to noxious heat, 50% to cooling, and >70% to histamine, chloroquine, AITC, and capsaicin. Fifty-seven percent responded to bombesin, suggesting that they participate in spinal itch transmission. That most ET-1-sensitive spinal neurons also responded to pruritic and algesic stimuli is consistent with previous studies of pruritogen-responsive dorsal horn neurons. We previously hypothesized that pruritogen-sensitive neurons signal itch. The observation that ET-1 activates nociceptive neurons suggests that both itch and pain signals may be generated by ET-1 to result in simultaneous sensations of itch and pain, consistent with observations that ET-1 elicits both itch- and pain-related behaviors in animals and burning itch sensations in humans. PMID:26311187
Indium Single-Ion Frequency Standard
NASA Technical Reports Server (NTRS)
Nagourney, Warren
2001-01-01
A single laser-cooled indium ion is a promising candidate for an ultimate resolution optical time or frequency standard. It can be shown that single ions from group IIIA of the periodic table (indium, thallium, etc.) can have extremely small systematic errors. In addition to being free from Doppler, transit-time and collisional shifts, these ions are also quite insensitive to perturbations from ambient magnetic and electric fields (mainly due to the use of a J=0-0 transition for spectroscopy). Of all group IIIA ions, indium seems to be the most practical, since it is heavy enough to have a tolerable intercombination cooling transition rate and (unlike thallium) has transitions which are easily accessible with frequency multiplied continuous-wave lasers. A single indium ion standard has a potential inaccuracy of one part in 10(exp 18) for integration times of 10(exp 6) seconds. We have made substantial progress during the grant period in constructing a frequency standard based upon a single indium ion. At the beginning of the grant period, single indium ions were being successfully trapped, but the lasers and optical systems were inadequate to achieve the desired goal. We have considerably improved the stability of the dye laser used to cool the ions and locked it to a molecular resonance line, making it possible to observe stable cooling-line fluorescence from a single indium ion for reasonable periods of time, as required by the demands of precision spectroscopy. We have substantially improved the single-ion fluorescence signal with significant benefits for the detection efficiency of forbidden transitions using the 'shelving' technique. Finally, we have constructed a compact, efficient UV 'clock' laser and observed 'clock' transitions in single indium ions using this laser system. We will elaborate on these accomplishments.
Intrinsic magnetic refrigeration of a single electron transistor
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ciccarelli, C.; Ferguson, A. J.; Campion, R. P.
In this work, we show that aluminium doped with low concentrations of magnetic impurities can be used to fabricate quantum devices with intrinsic cooling capabilities. We fabricate single electron transistors made of aluminium doped with 2% Mn by using a standard multi angle evaporation technique and show that the quantity of metal used to fabricate the devices generates enough cooling power to achieve a drop of 160 mK in the electron temperature at the base temperature of our cryostat (300 mK). The cooling mechanism is based on the magneto-caloric effect from the diluted Mn moments.
Navier-Stokes Simulation of Airconditioning Facility of a Large Modem Computer Room
NASA Technical Reports Server (NTRS)
2005-01-01
NASA recently assembled one of the world's fastest operational supercomputers to meet the agency's new high performance computing needs. This large-scale system, named Columbia, consists of 20 interconnected SGI Altix 512-processor systems, for a total of 10,240 Intel Itanium-2 processors. High-fidelity CFD simulations were performed for the NASA Advanced Supercomputing (NAS) computer room at Ames Research Center. The purpose of the simulations was to assess the adequacy of the existing air handling and conditioning system and make recommendations for changes in the design of the system if needed. The simulations were performed with NASA's OVERFLOW-2 CFD code which utilizes overset structured grids. A new set of boundary conditions were developed and added to the flow solver for modeling the roomls air-conditioning and proper cooling of the equipment. Boundary condition parameters for the flow solver are based on cooler CFM (flow rate) ratings and some reasonable assumptions of flow and heat transfer data for the floor and central processing units (CPU) . The geometry modeling from blue prints and grid generation were handled by the NASA Ames software package Chimera Grid Tools (CGT). This geometric model was developed as a CGT-scripted template, which can be easily modified to accommodate any changes in shape and size of the room, locations and dimensions of the CPU racks, disk racks, coolers, power distribution units, and mass-storage system. The compute nodes are grouped in pairs of racks with an aisle in the middle. High-speed connection cables connect the racks with overhead cable trays. The cool air from the cooling units is pumped into the computer room from a sub-floor through perforated floor tiles. The CPU cooling fans draw cool air from the floor tiles, which run along the outside length of each rack, and eject warm air into the center isle between the racks. This warm air is eventually drawn into the cooling units located near the walls of the room. One major concern is that the hot air ejected to the middle isle might recirculate back into the cool rack side and cause thermal short-cycling. The simulations analyzed and addressed the following important elements of the computer room: 1) High-temperature build-up in certain regions of the room; 2) Areas of low air circulation in the room; 3) Potential short-cycling of the computer rack cooling system; 4) Effectiveness of the perforated cooling floor tiles; 5) Effect of changes in various aspects of the cooling units. Detailed flow visualization is performed to show temperature distribution, air-flow streamlines and velocities in the computer room.
NASA Astrophysics Data System (ADS)
Warren, Clare J.; Singh, Athokpam K.; Roberts, Nick M. W.; Regis, Daniele; Halton, Alison M.; Singh, Rajkumar B.
2014-07-01
The Zimithang Thrust juxtaposes two lithotectonic units of the Greater Himalayan Sequence in Arunachal Pradesh, NE India. Monazite U-Pb, muscovite 40Ar/39Ar and thermobarometric data from rocks in the hanging and footwall constrain the timing and conditions of their juxtaposition across the structure, and their subsequent cooling. Monazite grains in biotite-sillimanite gneiss in the hanging wall yield LA-ICP-MS U-Pb ages of 16 ± 0.2 to 12.7 ± 0.4 Ma. A schistose gneiss within the high strain zone yields overlapping-to-younger monazite ages of 14.9 ± 0.3 to 11.5 ± 0.3 Ma. Garnet-staurolite-mica schists in the immediate footwall yield older monazite ages of 27.3 ± 0.6 to 17.1 ± 0.2 Ma. Temperature estimates from Ti-in-biotite and garnet-biotite thermometry suggest similar peak temperatures were achieved in the hanging and footwalls (~ 525-650 °C). Elevated temperatures of ~ 700 °C appear to have been reached in the high strain zone itself and in the footwall further from the thrust. Single grain fusion 40Ar/39Ar muscovite data from samples either side of the thrust yield ages of ~ 7 Ma, suggesting that movement along the thrust juxtaposed the two units by the time the closure temperature of Ar diffusion in muscovite had been reached. These data confirm previous suggestions that major orogen-parallel out-of-sequence structures disrupt the Greater Himalayan Sequence at different times during Himalayan evolution, and highlight an eastwards-younging trend in 40Ar/39Ar muscovite cooling ages at equivalent structural levels along Himalayan strike.
1975-01-29
will shut down automatically when condenser high pressure causes Pressure Limit Control high pressure switch to release. Press START switch (3...power cable (1) from facility pow- er. Troubleshoot cooling unit, for HI-LOW pressure switch repeated cutout. Refer to AGE ECU Cooling Unit...acti- vate when loss of air flow oc- curred, the pressure switch (3) failed to open circuit. Adjust or replace pressure switch . Refer to
NASA Astrophysics Data System (ADS)
Koley, Susmita; Ghosh, Indranil
Quick and periodic inflow-outflow of adsorbate in an adsorbent column createsa differential temperature between the two ends of it, allowing for the generation of continuous sorption cooling in a single adsorbent tube. The concept has been proven experimentally and theoretically for near room temperature applications using activated carbon-nitrogen. The feasibility of generating continuous solid sorption cooling in a single adsorbent tube in the cryogenic domainhas been studied theoretically with a different adsorbent-adsorbate pair, namely, activated carbon-hydrogen. Precooling of gaseous hydrogen (before it enters the adsorbent column) and removal of the heat of adsorption has been achieved using liquid nitrogen. Theoretical estimation shows nearly 20 K temperature difference between the two ends under no load condition. Finally, parametric variations have been performed.
Cooling of Gas Turbines. 2; Effectiveness of Rim Cooling of Blades
NASA Technical Reports Server (NTRS)
Wolfenstein, Lincoln; Meyer, Gene L.; McCarthy, John S.
1945-01-01
An analysis of rim cooling, which cools the blade by condition alone, was conducted. Gas temperatures ranged from 1300 degrees to 1900 degrees F and rim temperatures from 0 degrees to 1000 degrees F below gas temperatures. Results show that gas temperature increases up to 200 degrees F are permissible provided that the blades are cooled by 400 degrees to 500 degrees F below the gas temperature. Relatively small amounts of blade cooling, at constant gas temperature, give large increases in blade life. Dependence of rim cooling on heat-transfer coefficient, blade dimensions, and thermal conductivity is determined by a single parameter.
Solid oxide fuel cell/gas turbine trigeneration system for marine applications
NASA Astrophysics Data System (ADS)
Tse, Lawrence Kar Chung; Wilkins, Steven; McGlashan, Niall; Urban, Bernhard; Martinez-Botas, Ricardo
2011-03-01
Shipping contributes 4.5% to global CO2 emissions and is not covered by the Kyoto Agreement. One method of reducing CO2 emissions on land is combined cooling heating and power (CCHP) or trigeneration, with typical combined thermal efficiencies of over 80%. Large luxury yachts are seen as an ideal entry point to the off-shore market for this developing technology considering its current high cost. This paper investigates the feasibility of combining a SOFC-GT system and an absorption heat pump (AHP) in a trigeneration system to drive the heating ventilation and air conditioning (HVAC) and electrical base-load systems. A thermodynamic model is used to simulate the system, with various configurations and cooling loads. Measurement of actual yacht performance data forms the basis of this system simulation. It is found that for the optimum configuration using a double effect absorption chiller in Ship 1, the net electric power increases by 47% relative to the electrical power available for a conventional SOFC-GT-HVAC system. This is due to more air cooled to a lower temperature by absorption cooling; hence less electrical cooling by the conventional HVAC unit is required. The overall efficiency is 12.1% for the conventional system, 34.9% for the system with BROAD single effect absorption chiller, 43.2% for the system with double effect absorption chiller. This shows that the overall efficiency of a trigeneration system is far higher when waste heat recovery happens. The desiccant wheel hardly reduces moisture from the outdoor air due to a relative low mass flow rate of fuel cell exhaust available to dehumidify a very large mass flow rate of HVAC air, Hence, desiccant wheel is not recommended for this application.
NASA Technical Reports Server (NTRS)
Shirron, Peter; DiPirro, Michael; Canavan, Edgar; Tuttle, James; King, Todd; Numazawa, Takenori
2003-01-01
Low temperature refrigeration is an increasingly vital technology for NASA s Space Science program since most detectors being developed for x-ray, IR and sub-millimeter missions must be cooled to below 100 mK in order to meet the requirements for energy and spatial resolution. For space applications, magnetic refrigeration has an inherent advantage over alternative techniques because it does not depend on gravity. Adiabatic demagnetization refrigerators, or ADRs, are relatively simple, solid state devices. The basic elements are a magnetocaloric refrigerant (usually an encapsulated paramagnetic salt) located in the bore of a superconducting magne$, and a heat switch linking the salt to a heat sink. The alignment of magnetic spins with the magnetic field causes the refrigerant to warm as the magnetic field increases and cool as the field decreases. Thus the simple process of magnetizing the refrigerant to high field with the heat switch closed, then demagnetizing it with the heat switch open allows one to obtain temperatures well below 100 mK using a heat sink as warm as 4.2 K. The refrigerant can maintain a low temperature for a length of time depending on the applied and parasitic heat loads, its mass, and the initial magnetic field strength. Typically ADRs are designed for 12-24 hours of hold time, after which they must be warmed up and recycled. The drawback to single-shot ADRs is that the cooling power per unit mass is relatively low. Refrigerants that are suitable for low temperature operation necessarily have low magnetic ion density, and therefore low entropy density. Since ADRs store entropy, systems with even modest cooling powers (a few microwatts) at temperatures below 100 mK tend to be massive, averaging 10-15 kg.
Laser cooling of molecules by zero-velocity selection and single spontaneous emission
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ooi, C. H. Raymond
2010-11-15
A laser-cooling scheme for molecules is presented based on repeated cycle of zero-velocity selection, deceleration, and irreversible accumulation. Although this scheme also employs a single spontaneous emission as in [Raymond Ooi, Marzlin, and Audretsch, Eur. Phys. J. D 22, 259 (2003)], in order to circumvent the difficulty of maintaining closed pumping cycles in molecules, there are two distinct features which make the cooling process of this scheme faster and more practical. First, the zero-velocity selection creates a narrow velocity-width population with zero mean velocity, such that no further deceleration (with many stimulated Raman adiabatic passage (STIRAP) pulses) is required. Second,more » only two STIRAP processes are required to decelerate the remaining hot molecular ensemble to create a finite population around zero velocity for the next cycle. We present a setup to realize the cooling process in one dimension with trapping in the other two dimensions using a Stark barrel. Numerical estimates of the cooling parameters and simulations with density matrix equations using OH molecules show the applicability of the cooling scheme. For a gas at temperature T=1 K, the estimated cooling time is only 2 ms, with phase-space density increased by about 30 times. The possibility of extension to three-dimensional cooling via thermalization is also discussed.« less
Cooling of a magmatic system under thermal chaotic mixing
NASA Astrophysics Data System (ADS)
Petrelli, Maurizio; El Omari, Kamal; Le Guer, Yves; Perugini, Diego
2015-04-01
The cooling of a melt undergoing chaotic advection is studied numerically for a magma with a temperature-dependent viscosity in a 2D cavity with moving boundary. Different statistical mixing and energy indicators are used to characterize the efficiency of cooling by thermal chaotic mixing. We show that different cooling rates can be obtained during the thermal mixing even of a single basaltic magmatic batch undergoing chaotic advection. This process can induce complex temperature patterns inside the magma chamber. The emergence of chaotic dynamics strongly affects the temperature field during time and greatly increases the cooling rates. This mechanism has implications for the lifetime of a magmatic body and may favor the appearance of chemical heterogeneities in igneous systems as a result of different crystallization rates. Results from this study also highlight that even a single magma batch can develop, under chaotic thermal advection, complex thermal and therefore compositional patterns resulting from different cooling rates, which can account for some natural features that, to date, have received unsatisfactory explanations. Among them, the production of magmatic enclaves showing completely different cooling histories compared with the host magma, compositional zoning in mineral phases, and the generation of large-scale compositionally zoning observed in many plutons worldwide.
Realization of compact, passively-cooled, high-flux photovoltaic prototypes
NASA Astrophysics Data System (ADS)
Feuermann, Daniel; Gordon, Jeffrey M.; Horne, Steve; Conley, Gary; Winston, Roland
2005-08-01
The materialization of a recent conceptual advance in high-flux photovoltaic concentrators into first-generation prototypes is reported. Our design strategy includes a tailored imaging dual-mirror (aplanatic) system, with a tapered glass rod that enhances concentration and accommodates larger optical errors. Designs were severely constrained by the need for ultra-compact (minimal aspect ratio) modules, simple passive heat rejection, liberal optical tolerances, incorporating off-the-shelf commercial solar cells, and pragmatic considerations of affordable fabrication technologies. Each unit has a geometric concentration of 625 and irradiates a single square 100 mm2 triple-junction high-efficiency solar cell at a net flux concentration of 500.
Application of cylindrical, triangular and hemispherical dimples in the film cooling technology
NASA Astrophysics Data System (ADS)
Khalatov, A. A.; Panchenko, N. A.; Severin, S. D.
2017-11-01
The results of film cooling numerical simulation over a flat plate with coolant supply through a single span-wise array of inclined (α = 30°) holes arranged inside cylindrical, triangular, and hemispherical dimples are represented in the paper. Such configurations are of a great practical interest for application in advanced blade cooling systems of high-performance gas turbines. The schemes with coolant supply into triangular and hemispherical dimples were first proposed and patented by the IET of the NAS of Ukraine. For numerical simulation the ANSYS CFX 14 commercial code was used. Numerical simulation were carried out in a wide range of the blowing ratio parameter varied from 0.5 to 2.0. For low blowing ratio parameter (m = 0.5) the laterally averaged film cooling efficiency is actually the same for all investigated schemes over the main film cooling area. In this area, the most simple in terms of the film cooling production technology configuration can be used. At the medium and high blowing ratios (m = 1.0 or higher) all investigated film cooling schemes allow to increase the laterally averaged film cooling efficiency in comparison with the traditional cooling scheme with single row of incline holes. In this case the configuration with coolant supply into triangular dimples of the «crater» type demonstrates the best film cooling efficiency due to significant reduction in the intensity and scale of the “kidney” vortex beyond configuration, as well as due to decrease in the coolant blowing non-uniformity factor.
Solar heating and cooling systems design and development. [prototype development
NASA Technical Reports Server (NTRS)
1977-01-01
The development of twelve prototype solar heating/cooling systems, six heating and six heating and cooling systems, two each for single family, multi-family, and commercial applications, is reported. Schedules and technical discussions, along with illustrations on the progress made from April 1, 1977 through June 30, 1977 are detailed.
Provisioning cooling elements for chillerless data centers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chainer, Timothy J.; Parida, Pritish R.
Systems and methods for cooling include one or more computing structure, an inter-structure liquid cooling system that includes valves configured to selectively provide liquid coolant to the one or more computing structures; a heat rejection system that includes one or more heat rejection units configured to cool liquid coolant; and one or more liquid-to-liquid heat exchangers that include valves configured to selectively transfer heat from liquid coolant in the inter-structure liquid cooling system to liquid coolant in the heat rejection system. Each computing structure further includes one or more liquid-cooled servers; and an intra-structure liquid cooling system that has valvesmore » configured to selectively provide liquid coolant to the one or more liquid-cooled servers.« less
Thibault, L; Beauséjour, A; Jacques, A; Ducas, E; Tremblay, M
2014-02-01
Many countries allow the overnight storage of whole blood (WB) at ambient temperature. Some countries, such as Canada, also require a rapid cooling of WB with an active cooling system. Given the significant operational constraints associated with current cooling systems, an alternative method for cooling and transporting WB at 20-24°C was evaluated. Phase 22 cooling packs (TCP Reliable Inc., USA) were used in combination with vacuum-insulated panel (VIP) boxes. Temperature profiles of simulated WB units were studied in extreme temperatures (-35 and 40°C). The quality of blood components prepared using Phase 22 packs and CompoCool-WB (Fresenius HemoCare, Germany) was studied. Phase 22 packs reduced the temperature of simulated WB bags from 37 to 24°C in 1·7 ± 0·2 h. Used in combination with VIP boxes, Phase 22 packs maintain the temperature of bags between 20 and 24°C for 15 and 24 h, compared to 2 and 11 h with CompoCool-WB, when exposed at -35 and 40°C, respectively. The quality of platelet concentrates and plasma was comparable, regardless of the cooling system used. For red blood cell units, per cent haemolysis on day 42 was slightly higher in products prepared after cooling with Phase 22 packs compared to CompoCool-WB (0·33 ± 0·15% vs. 0·21 ± 0·06%; P < 0·05). Phase 22 packs combined with VIP boxes are an acceptable alternative to butane-1,4-diol cooling systems. This system allows blood manufacturers to transport WB to processing facilities in a broad range of environmental conditions. © 2013 International Society of Blood Transfusion.
NASA Technical Reports Server (NTRS)
Makinen, Janice V.; Anchondo, Ian; Bue, Grant C.; Campbell, Colin; Colunga, Aaron
2012-01-01
The development of the Advanced Extravehicular Mobility Unit (AEMU) Portable Life Support System (PLSS) is currently underway at NASA Johnson Space Center. The AEMU PLSS features two new evaporative cooling systems, the Reduced Volume Prototype Spacesuit Water Membrane Evaporator (RVP SWME), and the Auxiliary Cooling Loop (ACL). The RVP SWME is the third generation of hollow fiber SWME hardware, and like its predecessors, RVP SWME provides nominal crewmember and electronics cooling by flowing water through porous hollow fibers. Water vapor escapes through the hollow fiber pores, thereby cooling the liquid water that remains inside of the fibers. This cooled water is then recirculated to remove heat from the crewmember and PLSS electronics. Major design improvements, including a 36% reduction in volume, reduced weight, and more flight like back-pressure valve, facilitate the packaging of RVP SWME in the AEMU PLSS envelope. In addition to the RVP SWME, the Auxiliary Cooling Loop (ACL), was developed for contingency crewmember cooling. The ACL is a completely redundant, independent cooling system that consists of a small evaporative cooler--the Mini Membrane Evaporator (Mini-ME), independent pump, independent feed-water assembly and independent Liquid Cooling Garment (LCG). The Mini-ME utilizes the same hollow fiber technology featured in the RVP SWME, but is only 25% of the size of RVP SWME, providing only the necessary crewmember cooling in a contingency situation. The ACL provides a number of benefits when compared with the current EMU PLSS contingency cooling technology; contingency crewmember cooling can be provided for a longer period of time, more contingency situations can be accounted for, no reliance on a Secondary Oxygen Vessel (SOV) for contingency cooling--thereby allowing a SOV reduction in size and pressure, and the ACL can be recharged-allowing the AEMU PLSS to be reused, even after a contingency event. The development of these evaporative cooling systems will contribute to a more robust and comprehensive AEMU PLSS.
Flame-Sprayed Y2O3 Films with Metal-EDTA Complex Using Various Cooling Agents
NASA Astrophysics Data System (ADS)
Komatsu, Keiji; Toyama, Ayumu; Sekiya, Tetsuo; Shirai, Tomoyuki; Nakamura, Atsushi; Toda, Ikumi; Ohshio, Shigeo; Muramatsu, Hiroyuki; Saitoh, Hidetoshi
2017-01-01
In this study, yttrium oxide (Y2O3) films were synthesized from a metal-ethylenediaminetetraacetic (metal-EDTA) complex by employing a H2-O2 combustion flame. A rotation apparatus and various cooling agents (compressed air, liquid nitrogen, and atomized purified water) were used during the synthesis to control the thermal history during film deposition. An EDTA·Y·H complex was prepared and used as the staring material for the synthesis of Y2O3 films with a flame-spraying apparatus. Although thermally extreme environments were employed during the synthesis, all of the obtained Y2O3 films showed only a few cracks and minor peeling in their microstructures. For instance, the Y2O3 film synthesized using the rotation apparatus with water atomization units exhibited a porosity of 22.8%. The maximum film's temperature after deposition was 453 °C owing to the high heat of evaporation of water. Cooling effects of substrate by various cooling units for solidification was dominated to heat of vaporization, not to unit's temperatures.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chainer, Timothy J.; Parida, Pritish R.
Systems and methods for cooling include one or more computing structure, an inter-structure liquid cooling system that includes valves configured to selectively provide liquid coolant to the one or more computing structures; a heat rejection system that includes one or more heat rejection units configured to cool liquid coolant; and one or more liquid-to-liquid heat exchangers that include valves configured to selectively transfer heat from liquid coolant in the inter-structure liquid cooling system to liquid coolant in the heat rejection system. Each computing structure further includes one or more liquid-cooled servers; and an intra-structure liquid cooling system that has valvesmore » configured to selectively provide liquid coolant to the one or more liquid-cooled servers.« less
Sharma, Geeta; Noohu, Majumi Mohamad
2014-09-01
Cryotherapy, in the form of ice massge is used to reduce inflammation after acute musculoskeletal injury or trauma. The potential negative effects of ice massage on proprioception are unknown, despite equivocal evidence supporting its effectiveness. The purpose of the study was to test the influence of cooling on weight discrimination ability and hence the performance in footballers. The study was of same subject experimental design (pretest-posttest design). Thirty male collegiate football players, whose mean age was 21.07 years, participated in the study. The participants were assessed for two functional performance tests, single leg hop test and crossed over hop test and weight discrimination ability before and after ice massage for 5 minutes on hamstrings muscle tendon. Pre cooling scores of Single Leg Hop Test of the dominant leg in the subjects was 166.65 (± 10.16) cm and post cooling scores of the dominant leg was 167.25 (± 11.77) cm. Pre cooling scores of Crossed Over Hop Test of the dominant leg in the subjects was 174.14 (± 8.60) cm and post cooling scores of the dominant leg was 174.45 (± 9.28) cm. Pre cooling scores of Weight Discrimination Differential Threshold of the dominant leg in the subjects was 1.625 ± 1.179 kg compared with post cooling scores of the dominant leg 1.85 (± 1.91) kg. Pre cooling scores of single leg hop and crossed over hop test of the dominant leg in the subjects compared with post cooling scores of the dominant leg showed no significant differences and it was also noted that the weight discrimination ability (weight discrimination differential threshold) didn't show any significant difference. All the values are reported as mean ± SD. This study provides additional evidence that proprioceptive acuity in the hamstring muscles (biceps femoris) remains largely unaffected after ice application to the hamstrings tendon (biceps femoris).
NASA Astrophysics Data System (ADS)
Panwisawas, Chinnapat; D'Souza, Neil; Collins, David M.; Bhowmik, Ayan; Roebuck, Bryan
2018-05-01
Time-dependent plastic deformation through stress relaxation and creep deformation during in-situ cooling of the as-cast single-crystal superalloy CMSX-4® has been studied via neutron diffraction, transmission electron microscopy, electro-thermal miniature testing, and analytical modeling across two temperature regimes. Between 1000 °C and 900 °C, stress relaxation prevails and gives rise to softening as evidenced by a decreased dislocation density and the presence of long segment stacking faults in γ phase. Lattice strains decrease in both the γ matrix and γ' precipitate phases. A constitutive viscoplastic law derived from in-situ isothermal relaxation test under-estimates the equivalent plastic strain in the prediction of the stress and strain evolution during cooling in this case. It is thereby shown that the history dependence of the microstructure needs to be taken into account while deriving a constitutive law and which becomes even more relevant at high temperatures approaching the solvus. Higher temperature cooling experiments have also been carried out between 1300 °C and 1150 °C to measure the evolution of stress and plastic strain close to the γ' solvus temperature. In-situ cooling of samples using ETMT shows that creep dominates during high-temperature deformation between 1300 °C and 1220 °C, but below a threshold temperature, typically 1220 °C work hardening begins to prevail from increasing γ' fraction and resulting in a rapid increase in stress. The history dependence of prior accumulated deformation is also confirmed in the flow stress measurements using a single sample while cooling. The saturation stresses in the flow stress experiments show very good agreement with the stresses measured in the cooling experiments when viscoplastic deformation is dominant. This study demonstrates that experimentation during high-temperature deformation as well as the history dependence of the microstructure during cooling plays a key role in deriving an accurate viscoplastic constitutive law for the thermo-mechanical process during cooling from solidification.
Synthesis and structural characterization of bulk Sb2Te3 single crystal
NASA Astrophysics Data System (ADS)
Sultana, Rabia; Gahtori, Bhasker; Meena, R. S.; Awana, V. P. S.
2018-05-01
We report the growth and characterization of bulk Sb2Te3 single crystal synthesized by the self flux method via solid state reaction route from high temperature melt (850˚C) and slow cooling (2˚C/hour) of constituent elements. The single crystal X-ray diffraction pattern showed the 00l alignment and the high crystalline nature of the resultant sample. The rietveld fitted room temperature powder XRD revealed the phase purity and rhombohedral structure of the synthesized crystal. The formation and analysis of unit cell structure further verified the rhombohedral structure composed of three quintuple layers stacked one over the other. The SEM image showed the layered directional growth of the synthesized crystal carried out using the ZEISS-EVOMA-10 scanning electron microscope The electrical resistivity measurement was carried out using the conventional four-probe method on a quantum design Physical Property Measurement System (PPMS). The temperature dependent electrical resistivity plot for studied Sb2Te3 single crystal depicts metallic behaviour in the absence of any applied magnetic field. The synthesis as well as the structural characterization of as grown Sb2Te3 single crystal is reported and discussed in the present letter.
Budding, Karin E.
1982-01-01
The Joe Lott Tuff Member of the Mount Belknap Volcanics is the largest rhyolitic ash-flow tuff sheet in the Marysvale volcanic field. It was erupted 19 m.y. ago, shortly after the changeover from intermediate-composition calc-alkalic volcanism to bimodal basalt-rhyolite volcanism. Eruption of the tuff resulted in the formation of the Mount Belknap Caldera whose pyroclastic intracaldera stratigraphy parallels that in the outflow facies. The Joe Loft Tuff Member is a composite ash-flow sheet that changes laterally from a simple cooling unit near the source to four distinct cooling units toward the distal end. The lowest of these units is the largest and most widespread; it is 64 m thick and contains a basal vitrophyre. Eruption of the lower unit led to the initial collapse of the caldera. The lower unit is followed upward by a 43 m middle unit, a 26 m pink-colored unit which is separated by a prominent air- fall layer, and a 31 m upper unit. The Joe Loft Tuff Member is an alkali rhyolite with 75.85-77.31 wt. % silica and 8.06-9.32 wt. % K2O+Na2O; the agpaitic index (Na2O+ K2O/Al2O3) is .77-.98. The tuff contains about I% phenocrysts of quartz, sanidine, oligoclase, augite, apatite, zircon, sphene, biotite, and oxidized Fe-Ti oxides. The basal vitrophyre contains accessory allanite, chevkinite, and magnesiohastingsite. The main cooling units are chemically and mineralogically zoned indicating that the magma chamber restratified prior to each major eruption. Within each of the two thickest cooling units, the mineralogy changes systematically upwards; the Or content and relative volume of sanidine decreases and An content of plagioclase increases. The basal vitrophyre of the lower unit has a bulk composition that lies in the thermal trough near the minima of Or-Ab-Q at 1 kb PH2O. Microprobe analyses of feldspar and chemical modeling on experimental systems indicate that pre-eruption temperatures were near 750?C and that the temperature increased during the eruption of the cooling units. The chemical gradients in the apatite and whole-rock data in the Joe Loft Tuff Member and the consistent mineral assemblages throughout the ash-flow cannot be explained by crystal settling. The fractionation of the Joe Lott Tuff Member appears to closer fit the model of convection-driven thermogravitational diffusion.
Solar heating and cooling system design and development
NASA Technical Reports Server (NTRS)
1978-01-01
The progress of the program during the sixth program quarter is reported. The program calls for the development and delivery of eight prototype solar heating and cooling systems for installation and operational test. The William O'Brien single-family heating system was installed and is operational. The New Castle single-family heating residence is under construction. The Kansas University (KU) system is in the final design stages. The 25 ton cooling subsystem for KU is the debugging stage. Pressure drops that were greater than anticipated were encountered. The 3 ton simulation work is being finalized and the design parameters for the Rankine system were determined from simulation output.
Small Scale Solar Cooling Unit in Climate Conditions of Latvia: Environmental and Economical Aspects
NASA Astrophysics Data System (ADS)
Jaunzems, Dzintars; Veidenbergs, Ivars
2010-01-01
The paper contributes to the analyses from the environmental and economical point of view of small scale solar cooling system in climate conditions of Latvia. Cost analyses show that buildings with a higher cooling load and full load hours have lower costs. For high internal gains, cooling costs are around 1,7 €/kWh and 2,5 €/kWh for buildings with lower internal gains. Despite the fact that solar cooling systems have significant potential to reduce CO2 emissions due to a reduction of electricity consumption, the economic feasibility and attractiveness of solar cooling system is still low.
Cooling of superconducting devices by liquid storage and refrigeration unit
Laskaris, Evangelos Trifon; Urbahn, John Arthur; Steinbach, Albert Eugene
2013-08-20
A system is disclosed for cooling superconducting devices. The system includes a cryogen cooling system configured to be coupled to the superconducting device and to supply cryogen to the device. The system also includes a cryogen storage system configured to supply cryogen to the device. The system further includes flow control valving configured to selectively isolate the cryogen cooling system from the device, thereby directing a flow of cryogen to the device from the cryogen storage system.
Potential Evaluation of Solar Heat Assisted Desiccant Hybrid Air Conditioning System
NASA Astrophysics Data System (ADS)
Tran, Thien Nha; Hamamoto, Yoshinori; Akisawa, Atsushi; Kashiwagi, Takao
The solar thermal driven desiccant dehumidification-absorption cooling hybrid system has superior advantage in hot-humid climate regions. The reasonable air processing of desiccant hybrid air conditioning system and the utility of clean and free energy make the system environment friendly and energy efficient. The study investigates the performance of the desiccant dehumidification air conditioning systems with solar thermal assistant. The investigation is performed for three cases which are combinations of solar thermal and absorption cooling systems with different heat supply temperature levels. Two solar thermal systems are used in the study: the flat plate collector (FPC) and the vacuum tube with compound parabolic concentrator (CPC). The single-effect and high energy efficient double-, triple-effect LiBr-water absorption cooling cycles are considered for cooling systems. COP of desiccant hybrid air conditioning systems are determined. The evaluation of these systems is subsequently performed. The single effect absorption cooling cycle combined with the flat plate collector solar system is found to be the most energy efficient air conditioning system.
Design of a 3-Stage ADR for the Soft X-Ray Spectrometer Instrument on the Astro-H Mission
NASA Technical Reports Server (NTRS)
Shirron, Peter J.; Kimball, Mark O.; Wegel, Donald C.; Canavan, Edgar R.; DiPirro, Michael J.
2011-01-01
The Japanese Astro-H mission will include the Soft X-ray Spectrometer (SXS) instrument, whose 36-pixel detector array of ultra-sensitive x-ray microcalorimeters requires cooling to 50 mK. This will be accomplished using a 3-stage adiabatic demagnetization refrigerator (ADR). The design is dictated by the need to operate with full redundancy with both a superfluid helium dewar at 1.3 K or below, and with a 4.5 K Joule-Thomson (JT) cooler. The ADR is configured as a 2-stage unit that is located in a well in the helium tank, and a third stage that is mounted to the top of the helium tank. The third stage is directly connected through two heat switches to the JT cooler and the helium tank, and manages heat flow between the two. When liquid helium is present, the 2-stage ADR operates in a single-shot manner using the superfluid helium as a heat sink. The third stage may be used independently to reduce the time-average heat load on the liquid to extend its lifetime. When the liquid is depleted, the 2nd and 3rd stages operate as a continuous ADR to maintain the helium tank at as low a temperature as possible - expected to be 1.2 K - and the 1st stage cools from that temperature as a single-stage, single-shot ADR. The ADR s design and operating modes are discussed, along with test results of the prototype 3-stage ADR.
Power module packaging with double sided planar interconnection and heat exchangers
Liang, Zhenxian; Marlino, Laura D.; Ning, Puqi; Wang, Fei
2015-05-26
A double sided cooled power module package having a single phase leg topology includes two IGBT and two diode semiconductor dies. Each IGBT die is spaced apart from a diode semiconductor die, forming a switch unit. Two switch units are placed in a planar face-up and face-down configuration. A pair of DBC or other insulated metallic substrates is affixed to each side of the planar phase leg semiconductor dies to form a sandwich structure. Attachment layers are disposed on outer surfaces of the substrates and two heat exchangers are affixed to the substrates by rigid bond layers. The heat exchangers, made of copper or aluminum, have passages for carrying coolant. The power package is manufactured in a two-step assembly and heating process where direct bonds are formed for all bond layers by soldering, sintering, solid diffusion bonding or transient liquid diffusion bonding, with a specially designed jig and fixture.
Reduction of physiological strain under a hot and humid environment by a hybrid cooling vest.
Chan, Albert P C; Yang, Y; Wong, Francis K W; Yam, Michael C H; Wong, Del P; Song, W F
2017-02-08
Cooling treatment is regarded as one of good practices to provide safe training conditions to athletic trainers in the hot environment. The present study aimed to investigate whether wearing a commercial lightweight and portable hybrid cooling vest that combines air ventilation fans with frozen gel packs was an effective means to reduce participants' body heat strain. In this within-subject repeated measures study, 10 male volunteers participated in two heat-stress trials (one with the cooling vest - COOL condition, and another without - CON condition, in a randomized order) inside a climatic chamber with a controlled ambient temperature 33 °C and relative humidity (RH) 75% on an experimental day. Each trial included a progressively incremental running test, followed by a 40 min post-exercise recovery. Core temperature (Tc), heart rate (HR), sweat rate, rating of perceived exertion (RPE), exercise duration, running distance, power output, and sweat rate were measured. When comparing the two conditions, a non-statistically significant moderate cooling effect in rate of increase in Tc (0.03±0.02 °C/min for COOL vs. 0.04±0.02 °C/min for CON, p=0.054, d=0.57), HR (3±1 bpm/min for COOL vs. 4±1 bpm/min for CON, p=0.229, d=0.40), and physiological strain index (PSI) (0.20±0.06 unit/min for COOL vs. 0.23±0.06 unit/min for CON, p=0.072, d=0.50) was found in the COOL condition during exercise. A non-statistically significant (p>0.05) trivial cooling effect (d<0.2) was observed between the COOL and CON conditions for measures of exercise duration, running distance, power output, sweat rate and RPE. It is concluded that the use of the hybrid cooling vest achieved a moderate cooling effect in lowering the rate of increase in physiological strain without impeding the performance of progressively incremental exercise in the heat.
NASA Astrophysics Data System (ADS)
Iwai, Sadanori; Miyazaki, Hiroshi; Tosaka, Taizo; Tasaki, Kenji; Urata, Masami; Ioka, Shigeru; Ishii, Yusuke
2013-11-01
We have been developing a conduction-cooled coil wound with YBCO-coated conductors for HTS applications. Previously, we have fabricated a coil composed of a stack of 12 single pancakes wound with 4 mm-wide YBCO tapes. This coil had a central magnetic field as high as 5.1 T at 10 K under conduction-cooled conditions. In the present study, we fabricated and tested a coil composed of a stack of four single pancakes wound with 12 mm-wide YBCO tapes. The total size of the coil and the Jc value of the tapes were almost the same as those of the former coil. At 77 K, the voltage-current characteristics showed a high n-value of 24, confirming that the coil had no degradation. Furthermore, in a conduction-cooled configuration at 20 K to 60 K, the coil showed a high n-value of over 20. At 20 K, the central magnetic field reached 5.9 T at 903 A, which is 1.3-times higher than that of the former coil.
Passive thermosyphon solar heating and cooling module with supplementary heating
NASA Technical Reports Server (NTRS)
1977-01-01
A collection of three quarterly reports from Sigma Research, Inc., covering progress and status from January through September 1977 are presented. Three heat exchangers are developed for use in a solar heating and cooling system for installation into single-family dwellings. Each exchanger consists of one heating and cooling module and one submerged electric water heating element.
NASA Astrophysics Data System (ADS)
Yao, Jianjun; Cao, Hu; Ge, Wenwei; Li, Jiefang; Viehland, D.
2009-08-01
We report the finding of a monoclinic MB phase in Pb(Zn1/3Nb2/3)O3-4.5%PbTiO3 single crystals. High precision x-ray diffraction investigations of [110] field cooled crystals have shown a transformation sequence of cubic(C)→tetragonal(T)→orthorhombic(O)→monoclinic(MB), which is different from that previously reported [A.-E. Renault et al., J. Appl. Phys. 97, 044105 (2005)]. Beginning in the zero-field-cooled condition at 383 K, a rhombohedral (R)→MB→O sequence was observed with increasing field. Coexisting MB and O phases were then found upon removal of field, which fully transformed to MB on cooling to room temperature.
Single-bubble boiling under Earth's and low gravity
NASA Astrophysics Data System (ADS)
Khusid, Boris; Elele, Ezinwa; Lei, Qian; Tang, John; Shen, Yueyang
2017-11-01
Miniaturization of electronic systems in terrestrial and space applications is challenged by a dramatic increase in the power dissipation per unit volume with the occurrence of localized hot spots where the heat flux is much higher than the average. Cooling by forced gas or liquid flow appears insufficient to remove high local heat fluxes. Boiling that involves evaporation of liquid in a hot spot and condensation of vapor in a cold region can remove a significantly larger amount of heat through the latent heat of vaporization than force-flow cooling can carry out. Traditional methods for enhancing boiling heat transfer in terrestrial and space applications focus on removal of bubbles from the heating surface. In contrast, we unexpectedly observed a new boiling regime of water under Earth's gravity and low gravity in which a bubble was pinned on a small heater up to 270°C and delivered a heat flux up to 1.2 MW/m2 that was as high as the critical heat flux in the classical boiling regime on Earth .Low gravity measurements conducted in parabolic flights in NASA Boeing 727. The heat flux in flight and Earth's experiments was found to rise linearly with increasing the heater temperature. We will discuss physical mechanisms underlying heat transfer in single-bubble boiling. The work supported by NASA Grants NNX12AM26G and NNX09AK06G.
Improvement of film cooling effectiveness with a small downstream block body
NASA Astrophysics Data System (ADS)
Khorsi, A.; Guelailia, A.; Hamidou, M. K.
2016-07-01
The aim of this study is to predict the improvement in film cooling performance over a flat plate through a single row of cylindrical holes with different streamwise angles by using the Ansys CFX software package. In order to improve the film cooling effectiveness, a short crescent-shaped block is placed downstream of a cylindrical cooling hole. The numerical results of the cylindrical hole without the downstream short crescent-shaped block are compared with experimental data.
Fan, Meng; Wang, Minglei; Zhang, Kai; Liu, Yanhui; Schroers, Jan; Shattuck, Mark D; O'Hern, Corey S
2017-02-01
Amorphous solids, such as metallic, polymeric, and colloidal glasses, display complex spatiotemporal response to applied deformations. In contrast to crystalline solids, during loading, amorphous solids exhibit a smooth crossover from elastic response to plastic flow. In this study, we investigate the mechanical response of binary Lennard-Jones glasses to athermal, quasistatic pure shear as a function of the cooling rate used to prepare them. We find several key results concerning the connection between strain-induced particle rearrangements and mechanical response. We show that the energy loss per strain dU_{loss}/dγ caused by particle rearrangements for more rapidly cooled glasses is larger than that for slowly cooled glasses. We also find that the cumulative energy loss U_{loss} can be used to predict the ductility of glasses even in the putative linear regime of stress versus strain. U_{loss} increases (and the ratio of shear to bulk moduli decreases) with increasing cooling rate, indicating enhanced ductility. In addition, we characterized the degree of reversibility of particle motion during a single shear cycle. We find that irreversible particle motion occurs even in the linear regime of stress versus strain. However, slowly cooled glasses, which undergo smaller rearrangements, are more reversible during a single shear cycle than rapidly cooled glasses. Thus, we show that more ductile glasses are also less reversible.
The Thermal Evaluation of Air-Cooled Electronic Equipment
1952-09-01
of Unit with Case-Envelope Heat Exchanger 233 VII-7 Storking Plot for Evaluation of Case Heat Transfer of Unit with Integrated or Separate... wing . 1. Case Cooled by Free Convection and Radiation Equipment of this type which depends on the natural heat dissipative capacity of the outer...described application, a tightly-fitting spring- clip is placed around the component, such as a tube, with the two thermocouple lead wires spot-welded
Cooling devices and methods for use with electric submersible pumps
Jankowski, Todd A; Hill, Dallas D
2014-12-02
Cooling devices for use with electric submersible pump motors include a refrigerator attached to the end of the electric submersible pump motor with the evaporator heat exchanger accepting all or a portion of the heat load from the motor. The cooling device can be a self-contained bolt-on unit, so that minimal design changes to existing motors are required.
Cooling devices and methods for use with electric submersible pumps
Jankowski, Todd A.; Hill, Dallas D.
2016-07-19
Cooling devices for use with electric submersible pump motors include a refrigerator attached to the end of the electric submersible pump motor with the evaporator heat exchanger accepting all or a portion of the heat load from the motor. The cooling device can be a self-contained bolt-on unit, so that minimal design changes to existing motors are required.
High-Performance Computing Data Center Cooling System Energy Efficiency |
approaches involve a cooling distribution unit (CDU) (2), which interfaces with the facility cooling loop and to the energy recovery water (ERW) loop (5), which is a closed-loop system. There are three heat rejection options for this IT load: When possible, heat energy from the energy recovery loop is transferred
Cooling of a Magmatic System Under Thermal Chaotic Mixing
NASA Astrophysics Data System (ADS)
El Omari, Kamal; Le Guer, Yves; Perugini, Diego; Petrelli, Maurizio
2015-07-01
The cooling of a basaltic melt undergoing chaotic advection is studied numerically for a magma with a temperature-dependent viscosity in a two-dimensional (2D) cavity with moving boundary. Different statistical mixing and energy indicators are used to characterize the efficiency of cooling by thermal chaotic mixing. We show that different cooling rates can be obtained during the thermal mixing of a single basaltic magmatic batch undergoing chaotic advection. This process can induce complex temperature patterns inside the magma chamber. The emergence of chaotic dynamics strongly modulates the temperature fields over time and greatly increases the cooling rates. This mechanism has implications for the thermal lifetime of the magmatic body and may favor the appearance of chemical heterogeneities in the igneous system as a result of different crystallization rates. Results from this study also highlight that even a single magma batch can develop, under chaotic thermal advection, complex thermal and therefore compositional patterns resulting from different cooling rates, which can account for some natural features that, to date, have received unsatisfactory explanations, including the production of magmatic enclaves showing completely different cooling histories compared with the host magma, compositional zoning in mineral phases, and the generation of large-scale compositional zoning observed in many plutons worldwide.
Carver, D A; Ball, B A
2002-11-01
Previous studies have demonstrated a detrimental effect of seminal plasma on the maintenance of motility of cooled equine spermatozoa; however, the mechanism for the adverse effect of seminal plasma during cooled storage remains undetermined. In goats, a glycoprotein component of bulbourethral gland secretion contains lipase activity that is detrimental to sperm motility when stored in skim milk-based extenders. The objective of the current study was to determine the amount of lipase activity in stallion seminal plasma and to determine the effect of added lipase on spermatozoal motility during cooled semen storage. In the first experiment, seminal plasma (1.0 ml) was assayed for lipase activity based upon hydrolysis of triglycerides (olive oil substrate) into free fatty acids and subsequent titration of pH change (SigmaDiagnostic Lipase Kit). Lipase activity in stallion seminal plasma was 0.36 +/- 0.02 Sigma units/ml, (mean + S.E.M.; n = 16 ejaculates from six stallions). In the second experiment, equine semen (three ejaculates from each of four stallions) was divided into five treatment aliquots. In Treatment 1, semen was extended 1:3 with nonfat dried skim milk extender (NFDSM). In treatment groups 2 through 5, spermatozoa were washed by centrifugation (300 x g for 15 min) and resuspended in NFDSM to a final concentration of 25 x 10(6) spermatozoa/ml. Porcine pancreatic lipase (pPL) was added to Treatment 3 (10 pPL units/ml), Treatment 4 (100 pPL units/ml) and Treatment 5 (100 pPL units/ml, heat inactivated at 100 degrees C for 5 min) while Treatment 2 had no pancreatic lipase added and served as the control. Samples were cooled slowly to 5 degrees C, and stored at 5 degrees C until evaluation. Sperm motility was evaluated at time 0, 24, 48 and 72 h by computerized semen analysis, and data were analyzed via repeated measures ANOVA. The addition of 100 units/ml but not 10 units/ml of pPL decreased (P < 0.01) total and progressive motility of stored sperm. Heat-inactivated pPL (Treatment 5) did not significantly decrease motility of spermatozoa during storage. Because the lipase activity assayed (Sigma units) and the lipase activity added to cooled semen (pPL units) were not equivalent, pPL was assayed in the Sigma Diagnostic Lipase assay. The relationship between Sigma Units (Y) and pPL units (X) appeared to be a log-linear relationship with log(Y) = -0.912 + 0.007X; R2 = 0.90. Mean lipase activity assayed in stallion seminal plasma was equivalent to approximately 64 pPL units/ml. These data suggest that endogenous lipase activity in stallion seminal plasma may be a factor in the adverse effects of seminal plasma on cooled spermatozoa in some stallions.
NASA Astrophysics Data System (ADS)
Davies, Ben; Crowther, Paul A.; Beasor, Emma R.
2018-05-01
The empirical upper luminosity boundary Lmax of cool supergiants, often referred to as the Humphreys-Davidson limit, is thought to encode information on the general mass-loss behaviour of massive stars. Further, it delineates the boundary at which single stars will end their lives stripped of their hydrogen-rich envelope, which in turn is a key factor in the relative rates of Type-II to Type-Ibc supernovae from single star channels. In this paper we have revisited the issue of Lmax by studying the luminosity distributions of cool supergiants (SGs) in the Large and Small Magellanic Clouds (LMC/SMC). We assemble samples of cool SGs in each galaxy which are highly-complete above log L/L⊙=5.0, and determine their spectral energy distributions from the optical to the mid-infrared using modern multi-wavelength survey data. We show that in both cases Lmax appears to be lower than previously quoted, and is in the region of log L/L⊙=5.5. There is no evidence for Lmax being higher in the SMC than in the LMC, as would be expected if metallicity-dependent winds were the dominant factor in the stripping of stellar envelopes. We also show that Lmax aligns with the lowest luminosity of single nitrogen-rich Wolf-Rayet stars, indicating of a change in evolutionary sequence for stars above a critical mass. From population synthesis analysis we show that the Geneva evolutionary models greatly over-predict the numbers of cool SGs in the SMC. We also argue that the trend of earlier average spectral types of cool SGs in lower metallicity environments represents a genuine shift to hotter temperatures. Finally, we use our new bolometric luminosity measurements to provide updated bolometric corrections for cool supergiants.
NASA Astrophysics Data System (ADS)
Vdovin, V. F.; Grachev, V. G.; Dryagin, S. Yu.; Eliseev, A. I.; Kamaletdinov, R. K.; Korotaev, D. V.; Lesnov, I. V.; Mansfeld, M. A.; Pevzner, E. L.; Perminov, V. G.; Pilipenko, A. M.; Sapozhnikov, B. D.; Saurin, V. P.
2016-01-01
We report a design solution for a highly reliable, low-noise and extremely efficient cryogenically cooled transmit/receive unit for a large antenna system meant for radio-astronomical observations and deep-space communications in the X band. We describe our design solution and the results of a series of laboratory and antenna tests carried out in order to investigate the properties of the cryogenically cooled low-noise amplifier developed. The transmit/receive unit designed for deep-space communications (Mars missions, radio observatories located at Lagrangian point L2, etc.) was used in practice for communication with live satellites including "Radioastron" observatory, which moves in a highly elliptical orbit.
NASA Astrophysics Data System (ADS)
Chady, Tomasz; Gorący, Krzysztof
2018-04-01
Active infrared thermography is increasingly used for nondestructive testing of various materials. Properties of this method are creating a unique possibility to utilize it for inspection of composites. In the case of active thermography, an external energy source is usually used to induce a thermal contrast inside tested objects. The conventional heating methods (like halogen lamps or flash lamps) are utilized for this purpose. In this study, we propose to use a cooling unit. The proposed system consists of a thermal imaging infrared camera, which is used to observe the surface of the inspected specimen and a specially designed cooling unit with thermoelectric modules (the Peltier modules).
Solar heating and cooling systems design and development
NASA Technical Reports Server (NTRS)
1976-01-01
Solar heating and heating/cooling systems were designed for single family, multifamily, and commercial applications. Subsystems considered included solar collectors, heat storage systems, auxiliary energy sources, working fluids, and supplementary controls, piping, and pumps.
Rotating diffuser for pressure recovery in a steam cooling circuit of a gas turbine
Eldrid, Sacheverel Q.; Salamah, Samir A.; DeStefano, Thomas Daniel
2002-01-01
The buckets of a gas turbine are steam-cooled via a bore tube assembly having concentric supply and spent cooling steam return passages rotating with the rotor. A diffuser is provided in the return passage to reduce the pressure drop. In a combined cycle system, the spent return cooling steam with reduced pressure drop is combined with reheat steam from a heat recovery steam generator for flow to the intermediate pressure turbine. The exhaust steam from the high pressure turbine of the combined cycle unit supplies cooling steam to the supply conduit of the gas turbine.
66. INTERIOR VIEW OF THE COOLING BUILDING, LOOKING AM DAMPERS, ...
66. INTERIOR VIEW OF THE COOLING BUILDING, LOOKING AM DAMPERS, HIGH TEMPERATURE AND LOW TEMPERATURE COOLERS. APRIL 11, 1919. - United States Nitrate Plant No. 2, Reservation Road, Muscle Shoals, Muscle Shoals, Colbert County, AL
Traeholt, Chresten; Willen, Dag; Roden, Mark; Tolbert, Jerry C.; Lindsay, David; Fisher, Paul W.; Nielsen, Carsten Thidemann
2016-05-03
Cable end section comprises end-parts of N electrical phases/neutral, and a thermally-insulation envelope comprising cooling fluid. The end-parts each comprises a conductor and are arranged with phase 1 innermost, N outermost surrounded by the neutral, electrical insulation being between phases and N and neutral. The end-parts comprise contacting surfaces located sequentially along the longitudinal extension of the end-section. A termination unit has an insulating envelope connected to a cryostat, special parts at both ends comprising an adapter piece at the cable interface and a closing end-piece terminating the envelope in the end-section. The special parts houses an inlet and/or outlet for cooling fluid. The space between an inner wall of the envelope and a central opening of the cable is filled with cooling fluid. The special part at the end connecting to the cryostat houses an inlet or outlet, splitting cooling flow into cable annular flow and termination annular flow.
Dry coolers and air-condensing units (Review)
NASA Astrophysics Data System (ADS)
Milman, O. O.; Anan'ev, P. A.
2016-03-01
The analysis of factors affecting the growth of shortage of freshwater is performed. The state and dynamics of the global market of dry coolers used at electric power plants are investigated. Substantial increase in number and maximum capacity of air-cooled condensers, which have been put into operation in the world in recent years, are noted. The key reasons facilitating the choice of developers of the dry coolers, in particular the independence of the location of thermal power plant from water sources, are enumerated. The main steam turbine heat removal schemes using air cooling are considered, their comparison of thermal efficiency is assessed, and the change of three important parameters, such as surface area of heat transfer, condensate pump flow, and pressure losses in the steam exhaust system, are estimated. It is shown that the most effective is the scheme of direct steam condensation in the heat-exchange tubes, but other schemes also have certain advantages. The air-cooling efficiency may be enhanced much more by using an air-cooling hybrid system: a combination of dry and wet cooling. The basic applied constructive solutions are shown: the arrangement of heat-exchange modules and the types of fans. The optimal mounting design of a fully shopassembled cooling system for heat-exchange modules is represented. Different types of heat-exchange tubes ribbing that take into account the operational features of cooling systems are shown. Heat transfer coefficients of the plants from different manufacturers are compared, and the main reasons for its decline are named. When using evaporative air cooling, it is possible to improve the efficiency of air-cooling units. The factors affecting the faultless performance of dry coolers (DC) and air-condensing units (ACU) and the ways of their elimination are described. A high velocity wind forcing reduces the efficiency of cooling systems and creates preconditions for the development of wind-driven devices. It is noted that global trends have a significant influence on the application of dry coolers in Russia, in view of the fact that some TPP have a surface condensers arrangement. The reasons that these systems are currently less efficient than the direct steam condensation in an air-cooled condenser are explained. It is shown that, in some cases, it is more reasonable to use mixing-type condensers in combination with a dry cooler. Measures for a full import substitution of steam exhaust heat removal systems are mentioned.
Sequential cooling insert for turbine stator vane
Jones, Russel B
2017-04-04
A sequential flow cooling insert for a turbine stator vane of a small gas turbine engine, where the impingement cooling insert is formed as a single piece from a metal additive manufacturing process such as 3D metal printing, and where the insert includes a plurality of rows of radial extending impingement cooling air holes alternating with rows of radial extending return air holes on a pressure side wall, and where the insert includes a plurality of rows of chordwise extending second impingement cooling air holes on a suction side wall. The insert includes alternating rows of radial extending cooling air supply channels and return air channels that form a series of impingement cooling on the pressure side followed by the suction side of the insert.
Continuous All-Optical Deceleration and Single-Photon Cooling of Molecular Beams
2014-02-21
PHYSICAL REVIEW A 89 , 023425 (2014) Continuous all-optical deceleration and single-photon cooling of molecular beams A. M. Jayich,1 A. C. Vutha,2 M...details including multilevel numerical simulations of strontium monohydride. These techniques are applicable to a large number of molecular species and...molecules that are considered difficult to directly laser cool—a class that includes many 1050-2947/2014/ 89 (2)/023425(8) 023425-1 ©2014 American
Optoelectrical Cooling of Polar Molecules to Submillikelvin Temperatures.
Prehn, Alexander; Ibrügger, Martin; Glöckner, Rosa; Rempe, Gerhard; Zeppenfeld, Martin
2016-02-12
We demonstrate direct cooling of gaseous formaldehyde (H2CO) to the microkelvin regime. Our approach, optoelectrical Sisyphus cooling, provides a simple dissipative cooling method applicable to electrically trapped dipolar molecules. By reducing the temperature by 3 orders of magnitude and increasing the phase-space density by a factor of ∼10(4), we generate an ensemble of 3×10(5) molecules with a temperature of about 420 μK, populating a single rotational state with more than 80% purity.
2013-04-01
liquid nitrogen cooled mercury cadmium telluride ( MCT ) detector and compare their performance to a commercial FT-IR imaging instrument. We examine the...telluride ( MCT ) detector (InfraRed Associates, Stuart, FL), and in a second widefield imaging configuration, we employed a cooled focal plane array (FPA...experiment, a cooled focal plane array (FPA) was substituted for the bolometer. (b) A cooled single-element MCT detector is utilized with an adjustable
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kozubal, Eric J
LiquidCool Solutions (LCS) has developed liquid submerged server (LSS) technology that changes the way computer electronics are cooled. The technology provides an option to cool electronics by the direct contact flow of dielectric fluid (coolant) into a sealed enclosure housing all the electronics of a single server. The intimate dielectric fluid contact with electronics improves the effectiveness of heat removal from the electronics.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smith, J.E.; Whisnant, R.B.
The report provides an in-depth evaluation of an ultraviolet (UV) disinfection unit as applied to the treatment of cooling water in a textile air washer system. The UV unit tests used a teflon tube to transport the aquatic phase. The unit reduced microbial populations and maintained an average level of 10,000 Colony formed unites/mL for the 6-month testing period, without the addition of biocides. No cleaning or other maintenance was required of the wetted surfaces during the testing period. Slime deposits observed on walls of the air washer during chemical treatment were also eliminated. The UV unit can be utilizedmore » on both cooling towers and air washers without extensive installation.« less
NASA Astrophysics Data System (ADS)
Jansen, S. D.
1981-09-01
The ORBES region consists of all of Kentucky, most of West Virginia, substantial parts of Illinois, Indiana, and Ohio, and southwestern Pennsylvania. The inventory lists installed electrical generating capacity in commercial service as of December 1, 1976, and scheduled capacity additions and removals between 1977 and 1986 in the six ORBES states (Illinois, Indiana, Kentucky, Ohio, Pennsylvania, and West Virginia). The following information is included for each electrical generating unit: unit ID code, company index, whether point or industrial ownership, plant name, whether inside or outside the ORBES region, FIPS county code, type of unit, size in megawatts, type of megawatt rating, status of unit, data of commercial operation, scheduled retirement date, primary fuel, alternate fuel, type of cooling, source of cooling water, and source of information.
Solar heating and cooling systems design and development
NASA Technical Reports Server (NTRS)
1977-01-01
Progress in the development of prototype solar heating/cooling systems is reported. Results obtained from refinement/improvement of the single family, multifamily, and commercial systems configurations and generalized studies on several of the subsystems are presented.
ERIC Educational Resources Information Center
Fickes, Michael
2001-01-01
Explains a concept called cool roof that is used to reduce electricity costs for air conditioning, and also reduce the price of air conditioning units. Discusses the light reflecting capabilities of metal roofing as well as coatings that can stop leaks. (GR)
53. VIEW LOOKING S.E. AT THE CATALYZER BUILDINGS, COOLING SHEDS ...
53. VIEW LOOKING S.E. AT THE CATALYZER BUILDINGS, COOLING SHEDS AND ABSORPTION BUILDINGS IN THE BACKGROUND. MAY 29, 1919. - United States Nitrate Plant No. 2, Reservation Road, Muscle Shoals, Muscle Shoals, Colbert County, AL
PERSPECTIVE VIEW LOOKING NORTHWEST AT CYANAMIDE (LN) COOLING SHED, MILL ...
PERSPECTIVE VIEW LOOKING NORTHWEST AT CYANAMIDE (L-N) COOLING SHED, MILL BUILDING AND CONVEYOR BRIDGE. NOTE CORNERSTONE ON THE MILL BUILDING. - United States Nitrate Plant No. 2, Reservation Road, Muscle Shoals, Muscle Shoals, Colbert County, AL
Conceptual Design of a Condensing Heat Exchanger for Space Systems Using Porous Media
NASA Technical Reports Server (NTRS)
Hasan, Mohammad M.; Khan, Lutful I.; Nayagam, Vedha; Balasubramaniam, Ramaswamy
2006-01-01
Condensing heat exchangers are used in many space applications in the thermal and humidity control systems. In the International Space Station (ISS), humidity control is achieved by using a water cooled fin surface over which the moist air condenses, followed by "slurper bars" that take in both the condensate and air into a rotary separator and separates the water from air. The use of a cooled porous substrate as the condensing surface provides and attractive alternative that combines both heat removal as well as liquid/gas separation into a single unit. By selecting the pore sizes of the porous substrate a gravity independent operation may also be possible with this concept. Condensation of vapor into and on the porous surface from the flowing air and the removal of condensate from the porous substrate are the critical processes involved in the proposed concept. This paper describes some preliminary results of the proposed condensate withdrawal process and discusses the on-going design and development work of a porous media based condensing heat exchanger at the NASA Glenn Research Center in collaboration with NASA Johnson Space Center.
A lab-based study of subground passive cooling system for indoor temperature control
NASA Astrophysics Data System (ADS)
Chok, Mun-Hong; Chan, Chee-Ming
2017-11-01
Passive cooling is an alternative cooling technique which helps to reduce high energy consumption. Respectively, dredged marine soil (DMS) is either being dumped or disposed as waste materials. Dredging works had resulted high labor cost, therefore reuse DMS as to fill it along the coastal area. In this study, DMS chosen to examine the effectiveness of passive cooling system by model tests. Soil characterization were carried out according to BS1377: Part 2: 1990. Model were made into scale of 3 cm to 1 m. Heat exchange unit consists of three pipe designs namely, parallel, ramp and spiral. Preliminary tests including flow rate test and soil sample selection were done to select the best heat exchange unit to carry out the model test. Model test is classified into 2 conditions, day and night, each condition consists of 4 configurations which the temperature results are determined. The result shows that window left open and fan switched on (WO/FO) recorded the most effective cooling effects, from 29 °C to 27 °C with drop of 6.9 %.
Coupling Network Computing Applications in Air-cooled Turbine Blades Optimization
NASA Astrophysics Data System (ADS)
Shi, Liang; Yan, Peigang; Xie, Ming; Han, Wanjin
2018-05-01
Through establishing control parameters from blade outside to inside, the parametric design of air-cooled turbine blade based on airfoil has been implemented. On the basis of fast updating structure features and generating solid model, a complex cooling system has been created. Different flow units are modeled into a complex network topology with parallel and serial connection. Applying one-dimensional flow theory, programs have been composed to get pipeline network physical quantities along flow path, including flow rate, pressure, temperature and other parameters. These inner units parameters set as inner boundary conditions for external flow field calculation program HIT-3D by interpolation, thus to achieve full field thermal coupling simulation. Referring the studies in literatures to verify the effectiveness of pipeline network program and coupling algorithm. After that, on the basis of a modified design, and with the help of iSIGHT-FD, an optimization platform had been established. Through MIGA mechanism, the target of enhancing cooling efficiency has been reached, and the thermal stress has been effectively reduced. Research work in this paper has significance for rapid deploying the cooling structure design.
NASA Astrophysics Data System (ADS)
Zhu, D. C.; Su, C. Q.; Deng, Y. D.; Wang, Y. P.; Liu, X.
2017-11-01
Automotive exhaust-based thermoelectric generators are currently a hot topic in energy recovery. The waste heat of automotive exhaust gas can be converted into electricity by means of thermoelectric modules. Generally, inserting fins into the cooling unit contributes to enhancing the heat transfer for a higher power output. However, the introduction of fins will result in a pressure drop in the cooling system. In current research, in order to enhance the heat transfer and avoid a large pressure drop, a cooling unit with cylindrical grooves on the interior surface was proposed. To evaluate the performance of the cylindrical grooves, different inner topologies, including a smooth interior surface,a smooth interior surface with inserted fins and an interior surface with cylindrical grooves, were compared. The results revealed that compared with the smooth interior surface, the smooth interior surface with inserted fins and the interior surface with cylindrical grooves both enhanced the heat transfer, but the interior surface with cylindrical grooves obtained a lower pressure drop. To improve the performance of the cylindrical grooves, different groove-depth ratios were tried, and the results showed that a groove-depth ratio of 0.081 could provide the best overall performance.
NASA Astrophysics Data System (ADS)
Zhu, D. C.; Su, C. Q.; Deng, Y. D.; Wang, Y. P.; Liu, X.
2018-06-01
Automotive exhaust-based thermoelectric generators are currently a hot topic in energy recovery. The waste heat of automotive exhaust gas can be converted into electricity by means of thermoelectric modules. Generally, inserting fins into the cooling unit contributes to enhancing the heat transfer for a higher power output. However, the introduction of fins will result in a pressure drop in the cooling system. In current research, in order to enhance the heat transfer and avoid a large pressure drop, a cooling unit with cylindrical grooves on the interior surface was proposed. To evaluate the performance of the cylindrical grooves, different inner topologies, including a smooth interior surface,a smooth interior surface with inserted fins and an interior surface with cylindrical grooves, were compared. The results revealed that compared with the smooth interior surface, the smooth interior surface with inserted fins and the interior surface with cylindrical grooves both enhanced the heat transfer, but the interior surface with cylindrical grooves obtained a lower pressure drop. To improve the performance of the cylindrical grooves, different groove-depth ratios were tried, and the results showed that a groove-depth ratio of 0.081 could provide the best overall performance.
Navy Expeditionary Technology Transition Program (NETTP)
2012-03-02
water vapor from feed air using a zeolite membrane •Temperature/Humidity levels can be met in warm, humid climates without reheating •Allows higher...UNCLASSIFIED, Distribution Unlimited Modular Thermal Hub •Small, efficient absorption cooling •Energy source: Combustion, low- grade waste heat, solar... thermal energy •Reversible operation enables space cooling and heating, and water heating •Modular cooling and heating unit •Monolithic packaging offers
Diagnostics and Optimization of a Miniature High Frequency Pulse Tube Cryocooler
NASA Astrophysics Data System (ADS)
Garaway, I.; Veprik, A.; Radebaugh, R.
2010-04-01
A miniature, high energy density, pulse tube cryocooler with an inertance tube and reservoir has been developed, tested, diagnosed and optimized to provide appropriate cooling for size-limited cryogenic applications demanding fast cool down. This cryocooler, originally designed using REGEN 3.2 for 80 K, an operating frequency of 150 Hz and an average pressure of 5.0 MPa, has regenerator dimensions of 4.4 mm inside diameter and 27 mm length and is filled with ♯635 mesh stainless steel screen. Various design features, such as the use of compact heat exchangers and a miniature linear compressor, resulted in a remarkably compact pulse tube cryocooler. In this report, we present the preliminary test results and the subsequent diagnostic and optimization sequence performed to improve the overall design and operation of the complete cryocooler. These experimentally determined optimal parameters, though slightly different from those proposed in the initial numerical model, yielded 530 mW of gross cooling power at 120 K with an input electrical power of only 25 W. This study highlights the need to further establish our understanding of miniature, high frequency, regenerative cryocoolers, not only as a collection of independent subcomponents, but as one single working unit. It has also led to a list of additional improvements that may yet be made to even further improve the operating characteristics of such a complete miniature cryocooler.
Cellular mechanisms of desynchronizing effects of hypothermia in an in vitro epilepsy model.
Motamedi, Gholam K; Gonzalez-Sulser, Alfredo; Dzakpasu, Rhonda; Vicini, Stefano
2012-01-01
Hypothermia can terminate epileptiform discharges in vitro and in vivo epilepsy models. Hypothermia is becoming a standard treatment for brain injury in infants with perinatal hypoxic ischemic encephalopathy, and it is gaining ground as a potential treatment in patients with drug resistant epilepsy. However, the exact mechanism of action of cooling the brain tissue is unclear. We have studied the 4-aminopyridine model of epilepsy in mice using single- and dual-patch clamp and perforated multi-electrode array recordings from the hippocampus and cortex. Cooling consistently terminated 4-aminopyridine induced epileptiform-like discharges in hippocampal neurons and increased input resistance that was not mimicked by transient receptor potential channel antagonists. Dual-patch clamp recordings showed significant synchrony between distant CA1 and CA3 pyramidal neurons, but less so between the pyramidal neurons and interneurons. In CA1 and CA3 neurons, hypothermia blocked rhythmic action potential discharges and disrupted their synchrony; however, in interneurons, hypothermia blocked rhythmic discharges without abolishing action potentials. In parallel, multi-electrode array recordings showed that synchronized discharges were disrupted by hypothermia, whereas multi-unit activity was unaffected. The differential effect of cooling on transmitting or secreting γ-aminobutyric acid interneurons might disrupt normal network synchrony, aborting the epileptiform discharges. Moreover, the persistence of action potential firing in interneurons would have additional antiepileptic effects through tonic γ-aminobutyric acid release.
Highly Integrated THz Receiver Systems for Small Satellite Remote Sensing Applications
NASA Technical Reports Server (NTRS)
Groppi, Christopher; Hunter, Roger C.; Baker, Christopher
2017-01-01
We are developing miniaturized, highly integrated Schottky receiver systems suitable for use in CubeSats or other small spacecraft platforms, where state-of-the-art performance and ultra-low mass, power, and volume are required. Current traditional Schottky receivers are too large to employ on a CubeSat. We will develop highly integrated receivers operating from 520-600 GHz and 1040-1200 GHz that are based on state-of-the-art receivers already developed at Jet Propulsion Laboratory (JPL) by using novel 3D multi layer packaging. This process will reduce both mass and volume by more than an order of magnitude, while preserving state-of-the-art noise performance. The resulting receiver systems will have a volume of approximately 25 x 25 x 40 millimeters (mm), a mass of 250 grams (g), and power consumption on the order of of 7 watts (W). Using these techniques, we will also integrate both receivers into a single frame, further reducing mass and volume for applications where dual band operation is advantageous. Additionally, as Schottky receivers offer significant gains in noise performance when cooled to 100 K, we will investigate the improvement gained by passively cooling these receivers. Work by Sierra Lobo Inc., with their Cryo Cube technology development program, offers the possibility of passive cooling to 100 K on CubeSat platforms for 1-unit (1U) sized instruments.
Cement clinker structure during plasma-chemical synthesis and its influence on cement properties
NASA Astrophysics Data System (ADS)
Sazonova, N.; Skripnikova, N.; Lucenko, A.; Novikova, L.
2015-01-01
The aim of this study was to determine the degree of influence of cement clinker cooling modes, synthesized in a low-temperature plasma, its structure and physico-mechanical properties. The raw mixture consisting of marble, sand, ash from thermal power plants and py- rite cinders were used, which are characterized by saturation factor (1,045); silicate (2,35) and alumina (1,22) modules. It was found that the use of different cooling rates of fused cement clinker entails changes associated with the mineralogical composition (increase of alite of 8.719,2 %), morphology (variation of the mineral alite aspect ratio of 6,7-17,5), density of the structure (change in distance between the minerals from 1 to 7,5 microns), grindability, specific surface area (2600-3650 cm2/g) and, in consequence, the activity of cement (56,973,2 MPa). Disorientation of alite mineral blocks against each other, a significant amount of microcracks, affect the increase in cement specific surface area of 14,3-21,6 %, which leads to activity growth of the system. Along with this, with the rapid cooling of the samples, alite 54CaO- 16SiO2-Al2O3 MgO is formed, with single units of the structure, more deformed relatively to C3S, which has a positive effect on the hydraulic cement activity.
NASA Technical Reports Server (NTRS)
Pandey, Raghvendra K. (Inventor); Raina, Kanwal (Inventor); Solayappan, Narayanan (Inventor)
1994-01-01
A substantially single phase, single crystalline, highly epitaxial film of Bi.sub.2 CaSr.sub.2 Cu.sub.2 O.sub.8 superconductor which has a T.sub.c (zero resistance) of 83 K is provided on a lattice-matched substrate with no intergrowth. This film is produced by a Liquid Phase Epitaxy method which includes the steps of forming a dilute supercooled molten solution of a single phase superconducting mixture of oxides of Bi, Ca, Sr, and Cu having an atomic ratio of about 2:1:2:2 in a nonreactive flux such as KCl, introducing the substrate, e.g., NdGaO.sub.3, into the molten solution at 850.degree. C., cooling the solution from 850.degree. C. to 830.degree. C. to grow the film and rapidly cooling the substrate to room temperature to maintain the desired single phase, single crystalline film structure.
Cooling rate dependence of synthetic SD,PSD,MD magnetite
NASA Astrophysics Data System (ADS)
Koch, S.; Ferk, A.; Hess, K.; Leonhardt, R.
2010-12-01
The influence of the cooling rate on the thermoremanent magnetization is investigated experimentally. Several remelted volcanic glass samples as well as six samples of synthetic magnetite with grain sizes ranging from below 1 μm (single domain) to 12.1 μm (multidomain) are treated. The aim of this study is to investigate the theoretical log-linear relationship of magnetization acquisition with cooling rate and its domain state dependency. Earlier investigations suggest that an assemblage of non interacting SD particles acquires a larger TRM during slower cooling. Negative and/or MD particles, however, lead to a lower TRM after slower cooling rates. To avoid chemical alteration the synthetic samples are sealed in evacuated quartz glass tubes and stabilized thermally. Additionally, a natural phonolitic glass from Tenerife was investigated which was tempered for 10h. The dominating magnetic remanence carriers of the remelted volcanic glass are low titanium titanomagnetites. All samples are heated and cooled in the Earth magnetic field (approx. 48.000 nT) using 5 different cooling rates between 1 K/min and 15 K/m in the unblocking spectrum. The acquired TRM of all samples is measured after the controlled heating/cooling process using a cryogenic magnetometer of type 3G. Additional rock magnetic measurements like hysteresis loops are conducted for the remelted glasses to obtain an independent measure of domain state. Remelted glass samples show single domain characteristics in all rock magnetic measurements. As expected they acquire larger TRMs during slower cooling. Synthetic magnetite samples are currently measured. Unfortunately, due to problems with the cryogenic magnetometer, results were not available by the time of abstract submission.
Fuel Cell Thermal Management Through Conductive Cooling Plates
NASA Technical Reports Server (NTRS)
Colozza, Anthony J.; Burke, Kenneth A.
2008-01-01
An analysis was performed to evaluate the concept of utilizing conductive cooling plates to remove heat from a fuel cell stack, as opposed to a conventional internal cooling loop. The potential advantages of this type of cooling system are reduced stack complexity and weight and increased reliability through the reduction of the number of internal fluid seals. The conductive cooling plates would extract heat from the stack transferring it to an external coolant loop. The analysis was performed to determine the required thickness of these plates. The analysis was based on an energy balance between the thermal energy produced within the stack and the heat removal from the cooling plates. To accomplish the energy balance, the heat flow into and along the plates to the cooling fluid was modeled. Results were generated for various numbers of cells being cooled by a single cooling plate. The results provided cooling plate thickness, mass, and operating temperature of the plates. It was determined that utilizing high-conductivity pyrolitic graphite cooling plates can provide a specific cooling capacity (W/kg) equivalent to or potentially greater than a conventional internal cooling loop system.
Common Utilities in the Energy Systems Integration Facility | Energy
Systems Integration Facility. Common utilities include: Power: Three-phase 480/277 VAC, 208/120 VAC, 240 split-phase VAC, and 120 single-phase VAC Water: Process heating and cooling and research cooling
International Energy Agency Solar Heating and Cooling Program
NASA Astrophysics Data System (ADS)
Brooks, A. J.
This trip was undertaken to participate in and represent the United States Industry at the International Energy Agency (IEA) Solar Heating and Cooling Program (SHCP) Task 14 Workshop. The meeting took place at the A1 Bani Hotel in Rome Italy.
Overview of Resources for Geothermal Absorption Cooling for Buildings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Xiaobing; Gluesenkamp, Kyle R; Mehdizadeh Momen, Ayyoub
2015-06-01
This report summarizes the results of a literature review in three areas: available low-temperature/coproduced geothermal resources in the United States, energy use for space conditioning in commercial buildings, and state of the art of geothermal absorption cooling.
Implementation of a Legionella Ordinance for Multifamily Housing, Garland, Texas.
Whitney, Ellen A; Blake, Sarah; Berkelman, Ruth L
The incidence of legionellosis has sharply increased in the United States as a result of contaminated water systems. Jurisdictions across the country are considering whether to develop and implement regulations to protect individuals against Legionnaires' disease with its associated high morbidity and mortality. This article sheds light on the implementation and effectiveness of a 2005 citywide Legionella testing mandate of multifamily housing cooling towers in Garland, Texas. This ordinance has been in place for more than 10 years and represents the first of its kind in the United States to mandate routine testing of cooling towers for Legionella in multifamily housing. We utilized a mix of both qualitative and quantitative methods to explore the development, adoption, and implementation of the ordinance. Phone interviews were conducted with individuals from the City of Garland Health Department and apartment managers. Quantitative data included public health surveillance data on legionellosis. Barriers and facilitators of implementation, number and percentage of cooling towers from multifamily housing units that tested positive for Legionella by year, and number of legionellosis cases by year in Garland, Texas. Study outcomes highlight key themes that facilitated the successful implementation of the Legionella testing mandate, including the importance of timing, leadership support, stakeholder engagement, and education and outreach. The number of contaminated cooling towers was reduced over time. Mandatory monitoring for legionella in a local jurisdiction may result in reduced risk of legionellosis from cooling towers through raising awareness and education of building owners and managers about the need to prevent, detect, and remediate legionella contamination in their building water systems. Garland, Texas, broke new ground in the United States in moving toward primary prevention of legionellosis. The ordinance may be useful both in serving to educate and increase awareness about the need for Legionella prevention and to monitor effectiveness of maintenance procedures.
System design package for a solar heating and cooling system installed at Akron, Ohio
NASA Technical Reports Server (NTRS)
1979-01-01
Information used to evaluate the design of a solar heating, cooling, and domestic hot water system is given. A conventional heat pump provides summer cooling items as the design data brochure, system performance specification, system hazard analysis, spare parts list, and detailed design drawings. A solar system is installed in a single-family dwelling at Akron, Ohio, and at Duffield, Virginia.
Pāhoehoe flow cooling, discharge, and coverage rates from thermal image chronometry
Dehn, Jonathan; Hamilton, Christopher M.; Harris, A. J. L.; Herd, Richard A.; James, M.R.; Lodato, Luigi; Steffke, Andrea
2007-01-01
Theoretically- and empirically-derived cooling rates for active pāhoehoe lava flows show that surface cooling is controlled by conductive heat loss through a crust that is thickening with the square root of time. The model is based on a linear relationship that links log(time) with surface cooling. This predictable cooling behavior can be used assess the age of recently emplaced sheet flows from their surface temperatures. Using a single thermal image, or image mosaic, this allows quantification of the variation in areal coverage rates and lava discharge rates over 48 hour periods prior to image capture. For pāhoehoe sheet flow at Kīlauea (Hawai`i) this gives coverage rates of 1–5 m2/min at discharge rates of 0.01–0.05 m3/s, increasing to ∼40 m2/min at 0.4–0.5 m3/s. Our thermal chronometry approach represents a quick and easy method of tracking flow advance over a three-day period using a single, thermal snap-shot.
Performance Improvement of a Single Stage GM Cryocooler at 25 K
NASA Astrophysics Data System (ADS)
Wang, C.; Gifford, P. E.
2008-03-01
To meet the cooling demand of some HTS devices, Cryomech, Inc. has redesigned and improved a single stage GM cryocooler to have a maximum capacity at 25K. The losses in a rotary valve and a low temperature regenerator have been reduced. The improved GM cryocooler provides a cooling capacity of 109 W at 25 K with an input power of 10.4 kW while running with the 50Hz electrical source.
77 FR 65417 - Compliance With Information Request, Flooding Hazard Reevaluation
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-26
... operating units, however, the first large tsunami wave inundated the site, followed by additional waves. The... units. Unit 6 retained the function of one air-cooled EDG; Despite their actions, the operators lost the...
Platts, David A.
2002-01-01
There has been invented a turbine engine with a single rotor which cools the engine, functions as a radial compressor, pushes air through the engine to the ignition point, and acts as an axial turbine for powering the compressor. The invention engine is designed to use a simple scheme of conventional passage shapes to provide both a radial and axial flow pattern through the single rotor, thereby allowing the radial intake air flow to cool the turbine blades and turbine exhaust gases in an axial flow to be used for energy transfer. In an alternative embodiment, an electric generator is incorporated in the engine to specifically adapt the invention for power generation. Magnets are embedded in the exhaust face of the single rotor proximate to a ring of stationary magnetic cores with windings to provide for the generation of electricity. In this alternative embodiment, the turbine is a radial inflow turbine rather than an axial turbine as used in the first embodiment. Radial inflow passages of conventional design are interleaved with radial compressor passages to allow the intake air to cool the turbine blades.
Tg and Structural Recovery of Single Ultrathin Films
NASA Astrophysics Data System (ADS)
Simon, Sindee
The behavior of materials confined at the nanoscale has been of considerable interest over the past two decades. Here, the focus is on recent results for single polystyrene ultrathin films studied with ultrafast scanning chip calorimetry. The Tg depression of a 20 nm-thick high-molecular-weight polystyrene film is found to be a function of cooling rate, decreasing with increasing cooling rate; whereas, at high enough cooling rates (e.g., 1000 K/s), Tg is the same as the bulk within the error of the measurements. Structural recovery is also performed with chip calorimetry as a function of aging time and temperature, and the evolution of the fictive temperature is followed. The advantages of the Flash DSC include sufficient sensitivity to measure enthalpy recovery for a single 20 nm-thick film, as well as extension of the measurements to aging temperatures as high as 15 K above nominal Tg and to aging times as short as 0.01 s. The aging behavior and relaxation time-temperature map for single ultrathin films are compared to those for bulk material. Comparison to behavior in other geometries will also be discussed.
2012-07-01
vap erant vapor is or by a J-tub essure side of using similar pressure incre ump in order o the diesel-e per heat excha recovered at to the exhaus...top of the a tering the com at exchanger. g of the conve id flow. A nit essure pulsati tor where the ed in the cool erature level. ger where wa
Performance evaluation of Ormat unit at Wabuska, Nevada. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Culver, G.
1986-07-01
Three nominal 24 hour tests under summer, winter and spring weather conditions, were run on an Ormat geothermal binary power generation machine. The machine, located at TAD's Enterprises in Wabuska, Nevada is supplied with approximately 830 gpm of geothermal water at 221/sup 0/F and has two spray cooling ponds. During the tests, temperature, pressure, and flows of geothermal water, freon, cooling water and instantaneous electrical production were recorded hourly. At least once during each test, energy consumption of the well pump, freon feed pump and cooling water pumps were made. Power output of the machine is limited by spray pondmore » capacity. Net output ranged from 410.2 kW during summer conditions when cooling water was 65/sup 0/F to 610.4 kW during winter conditions when cooling water was 55/sup 0/F. Net resource utilization ranged from 1.005 Whr/lb during the summer test to 1.55 Whr/lb during the winter test. Spray pond performance averaged 63% for the fall and winter tests. Availability of the Ormat unit itself during the eight month test period was generally good, averaging 95.5%. Overall system availability, including well pumps, cooling system and electric grid was somewhat less - averaging 83%.« less
Army Ground Vehicles and Current/Future Emission Standards
2008-10-23
cooler’ combustion temperatures • Two stages of turbocharging (single stage for smaller displacement engines) • Additional charge air cooling...Recirculate and cool exhaust gas up or downstream of turbine ( turbocharger ) ; require back pressure restriction and/or intake throttle to flow
Efficient Raman sideband cooling of trapped ions to their motional ground state
NASA Astrophysics Data System (ADS)
Che, H.; Deng, K.; Xu, Z. T.; Yuan, W. H.; Zhang, J.; Lu, Z. H.
2017-07-01
Efficient cooling of trapped ions is a prerequisite for various applications of the ions in precision spectroscopy, quantum information, and coherence control. Raman sideband cooling is an effective method to cool the ions to their motional ground state. We investigate both numerically and experimentally the optimization of Raman sideband cooling strategies and propose an efficient one, which can simplify the experimental setup as well as reduce the number of cooling pulses. Several cooling schemes are tested and compared through numerical simulations. The simulation result shows that the fixed-width pulses and varied-width pulses have almost the same efficiency for both the first-order and the second-order Raman sideband cooling. The optimized strategy is verified experimentally. A single 25Mg+ ion is trapped in a linear Paul trap and Raman sideband cooled, and the achieved average vibrational quantum numbers under different cooling strategies are evaluated. A good agreement between the experimental result and the simulation result is obtained.
Prototype solar heating and cooling systems
NASA Technical Reports Server (NTRS)
1978-01-01
A collection of monthly status reports on the development of eight prototype solar heating and cooling systems is presented. The effort calls for the development, manufacture, test, system installation, maintenance, problem resolution, and performance evaluation. The systems are 3, 25, and 75 ton size units.
Prototype solar heating and cooling systems
NASA Technical Reports Server (NTRS)
1978-01-01
A collection of monthly status reports are given on the development of eight prototype solar heating and cooling systems. This effort calls for the development, manufacturing, test, system installation, maintenance, problem resolution, and performance evaluation. The systems are 3-, 25-, and 75-ton size units.
Influence of carrier density on the electronic cooling channels of bilayer graphene
NASA Astrophysics Data System (ADS)
Limmer, T.; Houtepen, A. J.; Niggebaum, A.; Tautz, R.; Da Como, E.
2011-09-01
We study the electronic cooling dynamics in a single flake of bilayer graphene by femtosecond transient absorption probing the photon-energy range 0.25-1.3 eV. From the transients, we extract the carrier cooling curves for different initial temperatures and densities of the photoexcited electrons and holes. Two regimes of carrier cooling, dominated by optical and acoustic phonons emission, are clearly identified. For increasing carrier density, the crossover between the two regimes occurs at larger carrier temperatures, since cooling via optical phonons experiences a bottleneck. Acoustic phonons, which are less sensitive to saturation, show an increasing contribution at high density.
Epitaxial layers of 2122 BCSCO superconductor thin films having single crystalline structure
NASA Technical Reports Server (NTRS)
Pandey, Raghvendra K. (Inventor); Raina, Kanwal K. (Inventor); Solayappan, Narayanan (Inventor)
1995-01-01
A substantially single phase, single crystalline, highly epitaxial film of Bi.sub.2 CaSr.sub.2 Cu.sub.2 O.sub.8 superconductor which has a T.sub.c (zero resistance) of 83K is provided on a lattice-matched substrate with no intergrowth. This film is produced by a Liquid Phase Epitaxy method which includes the steps of forming a dilute supercooled molten solution of a single phase superconducting mixture of oxides of Bi, Ca, Sr, and Cu having an atomic ratio of about 2:1:2:2 in a nonreactive flux such as KCl, introducing the substrate, e.g., NdGaO.sub.3, into the molten solution at 850.degree. C., cooling the solution from 850.degree. C. to 830.degree. C. to grow the film and rapidly cooling the substrate to room temperature to maintain the desired single phase, single crystalline film structure.
Shifting Pacific storm tracks as stressors to ecosystems of western North America.
Dannenberg, Matthew P; Wise, Erika K
2017-11-01
Much of the precipitation delivered to western North America arrives during the cool season via midlatitude Pacific storm tracks, which may experience future shifts in response to climate change. Here, we assess the sensitivity of the hydroclimate and ecosystems of western North America to the latitudinal position of cool-season Pacific storm tracks. We calculated correlations between storm track variability and three hydroclimatic variables: gridded cool-season standardized precipitation-evapotranspiration index, April snow water equivalent, and water year streamflow from a network of USGS stream gauges. To assess how historical storm track variability affected ecosystem processes, we derived forest growth estimates from a large network of tree-ring widths and land surface phenology and wildfire estimates from remote sensing. From 1980 to 2014, cool-season storm tracks entered western North America between approximately 41°N and 53°N. Cool-season moisture supply and snowpack responded strongly to storm track position, with positive correlations to storm track latitude in eastern Alaska and northwestern Canada but negative correlations in the northwestern U.S. Ecosystems of the western United States were greener and more productive following winters with south-shifted storm tracks, while Canadian ecosystems were greener in years when the cool-season storm track was shifted to the north. On average, larger areas of the northwestern United States were burned by moderate to high severity wildfires when storm tracks were displaced north, and the average burn area per fire also tended to be higher in years with north-shifted storm tracks. These results suggest that projected shifts of Pacific storm tracks over the 21st century would likely alter hydroclimatic and ecological regimes in western North America, particularly in the northwestern United States, where moisture supply and ecosystem processes are highly sensitive to the position of cool-season storm tracks. © 2017 John Wiley & Sons Ltd.
Reversible thermosalience of 4-aminobenzonitrile.
Alimi, Lukman O; van Heerden, Dewald P; Lama, Prem; Smith, Vincent J; Barbour, Leonard J
2018-05-31
Crystals of 4-aminobenzonitrile grown by sublimation undergo reversible thermosalient phase changes during cooling and subsequent heating. Single-crystal diffraction studies have been carried out at 20 K intervals during cooling from 300 to 100 K in order to explain the structural change that occurs.
Fukushima Daiichi Nuclear Accident; based on the Final Report of Atomic Energy Society of Japan
NASA Astrophysics Data System (ADS)
Sekimura, Naoto
2014-09-01
The Atomic Energy Society of Japan (AESJ) published the Final Report of the AESJ Investigation Committee on Fukushima Daiichi NPS Accident in March 2014. The AESJ is responsible to identify the underlying root causes of the accident through technical surveys and analyses, and to offer solutions for nuclear safety. At the Fukushima Daiichi, Units 1 to 3, which were under operation, were automatically shut down at 14:46 on March 11, 2011 by the Tohoku District-off the Pacific Ocean Earthquake. About 50 minutes later, the tsunami flooded and destroyed the emergency diesel generators, the seawater cooling pumps, the electric wiring system and the DC power for Units 1, 2 and 4, resulting in loss of all power except for an air-cooled emergency diesel generator at Unit 6. Unit 3 lost all AC power, and later lost DC before dawn of March 13. Cooling the reactors and monitoring the results were heavily dependent on electricity for high-pressure water injection, depressurizing the reactor, low pressure water injection, and following continuous cooling. In Unit 3, for example, recent re-evaluation in August 2014 by TEPCO shows that no cooling water was injected into the reactor core region after 8 PM on March 12, leading to the fuel melting from 5:30 AM on March 13. Even though seawater was injected from fire engines afterwards, the rupture of pressure vessel was caused and the majority of melted fuel dropped into the containment vessel of Unit 3. The estimation of amount of radioactive materials such as Xe-133, I-131, Cs-137 and Cs-134, emitted to the environment from Units 1 to 3 is discussed in the presentation. Direct causes of the accident identified in the AESJ Report were, 1) inadequate tsunami measures, 2) inadequate severe accident management measures and 3) inadequate emergency response, post-accident management/mitigation, and recovery measures. These were caused by the following underlying factors, i.e., a) lack of awareness on the roles and responsibilities by experts, b) shortfalls in establishing safety measures and fostering safety awareness by utilities, c) lack of safety awareness by the regulatory body, d) inadequacies in attitude of learning from efforts and collaborations in the international community, and e) shortage of qualified personnel to ensure safety and inadequacies in organization and management framework.
Revisiting the climate impacts of cool roofs around the globe using an Earth system model
NASA Astrophysics Data System (ADS)
Zhang, Jiachen; Zhang, Kai; Liu, Junfeng; Ban-Weiss, George
2016-08-01
Solar reflective ‘cool roofs’ absorb less sunlight than traditional dark roofs, reducing solar heat gain, and decreasing the amount of heat transferred to the atmosphere. Widespread adoption of cool roofs could therefore reduce temperatures in urban areas, partially mitigating the urban heat island effect, and contributing to reversing the local impacts of global climate change. The impacts of cool roofs on global climate remain debated by past research and are uncertain. Using a sophisticated Earth system model, the impacts of cool roofs on climate are investigated at urban, continental, and global scales. We find that global adoption of cool roofs in urban areas reduces urban heat islands everywhere, with an annual- and global-mean decrease from 1.6 to 1.2 K. Decreases are statistically significant, except for some areas in Africa and Mexico where urban fraction is low, and some high-latitude areas during wintertime. Analysis of the surface and TOA energy budget in urban regions at continental-scale shows cool roofs causing increases in solar radiation leaving the Earth-atmosphere system in most regions around the globe, though the presence of aerosols and clouds are found to partially offset increases in upward radiation. Aerosols dampen cool roof-induced increases in upward solar radiation, ranging from 4% in the United States to 18% in more polluted China. Adoption of cool roofs also causes statistically significant reductions in surface air temperatures in urbanized regions of China (-0.11 ± 0.10 K) and the United States (-0.14 ± 0.12 K); India and Europe show statistically insignificant changes. Though past research has disagreed on whether widespread adoption of cool roofs would cool or warm global climate, these studies have lacked analysis on the statistical significance of global temperature changes. The research presented here indicates that adoption of cool roofs around the globe would lead to statistically insignificant reductions in global mean air temperature (-0.0021 ± 0.026 K). Thus, we suggest that while cool roofs are an effective tool for reducing building energy use in hot climates, urban heat islands, and regional air temperatures, their influence on global climate is likely negligible.
Revisiting the Climate Impacts of Cool Roofs around the Globe Using an Earth System Model
NASA Astrophysics Data System (ADS)
Zhang, J.; Ban-Weiss, G. A.; Zhang, K.; Liu, J.
2016-12-01
Solar reflective "cool roofs" absorb less sunlight than traditional dark roofs, reducing solar heat gain, and decreasing the amount of heat transferred to the atmosphere. Widespread adoption of cool roofs could therefore reduce temperatures in urban areas, partially mitigating the urban heat island effect, and contributing to reversing the local impacts of global climate change. The impacts of cool roofs on global climate remain debated by past research and are uncertain. Using a sophisticated Earth system model, the impacts of cool roofs on climate are investigated at urban, continental, and global scales. We find that global adoption of cool roofs in urban areas reduces urban heat islands everywhere, with an annual- and global-mean decrease from 1.6 to 1.2 K. Decreases are statistically significant, except for some areas in Africa and Mexico where urban fraction is low, and some high-latitude areas during wintertime. Analysis of the surface and TOA energy budget in urban regions at continental-scale shows cool roofs causing increases in solar radiation leaving the Earth-atmosphere system in most regions around the globe, though the presence of aerosols and clouds are found to partially offset increases in upward radiation. Aerosols dampen cool roof-induced increases in upward solar radiation, ranging from 4% in the United States to 18% in more polluted China. Adoption of cool roofs also causes statistically significant reductions in surface air temperatures in urbanized regions of China (-0.11±0.10 K) and the United States (-0.14±0.12 K); India and Europe show statistically insignificant changes. Though past research has disagreed on whether widespread adoption of cool roofs would cool or warm global climate, these studies have lacked analysis on the statistical significance of global temperature changes. The research presented here indicates that adoption of cool roofs around the globe would lead to statistically insignificant reductions in global mean air temperature (-0.0021 ± 0.026 K). Thus, we suggest that while cool roofs are an effective tool for reducing building energy use in hot climates, urban heat islands, and regional air temperatures, their influence on global climate is likely negligible.
NASA Astrophysics Data System (ADS)
Bishop, Douglas M.; McCandless, Brian; Gershon, Talia; Lloyd, Michael A.; Haight, Richard; Birkmire, Robert
2017-02-01
Recent literature reports have shown the ability to manipulate Cu-Zn cation ordering for Cu2ZnSnSe4 (CZTSe) via low temperature treatments. Theoretical arguments suggest that one of the major roadblocks to higher VOC—significant band tailing—could be improved with increased cation order; however, few direct measurements have been reported and significant device improvements have not yet been realized. This report investigates electrical properties, defects, and devices from quenched and slow-cooled single crystals of CZTSe. The extent of disorder was characterized by Raman spectroscopy as well as x-ray diffraction, where the change in Cu-Zn order can be detected by a changing c/a ratio. Quenched samples show higher acceptor concentrations, lower hole mobilities, and a lower-energy photoluminescence (PL) peak than crystals cooled at slower rates, consistent with a reduction in the bandgap. In addition, samples quenched at the highest temperatures showed lower PL yield consistent with higher quantities of deep defects. Devices fabricated using slow-cooled CZTSe single crystals showed improved efficiencies, most notably with increased VOC; however, low temperature intensity-dependent photoluminescence measurements continue to indicate the existence of potential fluctuations. We discuss the possibility that potential fluctuations in slow-cooled samples may be related to the inability to achieve a long range order of the Cu-Zn sub-lattice resulting in local regions of high and low levels of cation order, and consequent local variations in the bandgap. The presence of significant potential fluctuations, even after the slow-cooling step, suggests the difficulty in eliminating band-tailing in this system, and thus, additional approaches may be needed for significant reduction of the VOC deficit.
Measurement of intrahepatic pressure during radiofrequency ablation in porcine liver.
Kawamoto, Chiaki; Yamauchi, Atsushi; Baba, Yoko; Kaneko, Keiko; Yakabi, Koji
2010-04-01
To identify the most effective procedures to avoid increased intrahepatic pressure during radiofrequency ablation, we evaluated different ablation methods. Laparotomy was performed in 19 pigs. Intrahepatic pressure was monitored using an invasive blood pressure monitor. Radiofrequency ablation was performed as follows: single-step standard ablation; single-step at 30 W; single-step at 70 W; 4-step at 30 W; 8-step at 30 W; 8-step at 70 W; and cooled-tip. The array was fully deployed in single-step methods. In the multi-step methods, the array was gradually deployed in four or eight steps. With the cooled-tip, ablation was performed by increasing output by 10 W/min, starting at 40 W. Intrahepatic pressure was as follows: single-step standard ablation, 154.5 +/- 30.9 mmHg; single-step at 30 W, 34.2 +/- 20.0 mmHg; single-step at 70 W, 46.7 +/- 24.3 mmHg; 4-step at 30 W, 42.3 +/- 17.9 mmHg; 8-step at 30 W, 24.1 +/- 18.2 mmHg; 8-step at 70 W, 47.5 +/- 31.5 mmHg; and cooled-tip, 114.5 +/- 16.6 mmHg. The radiofrequency ablation-induced area was spherical with single-step standard ablation, 4-step at 30 W, and 8-step at 30 W. Conversely, the ablated area was irregular with single-step at 30 W, single-step at 70 W, and 8-step at 70 W. The ablation time was significantly shorter for the multi-step method than for the single-step method. Increased intrahepatic pressure could be controlled using multi-step methods. From the shapes of the ablation area, 30-W 8-step expansions appear to be most suitable for radiofrequency ablation.
Heating and Cooling System Design for a Modern Transportable Container
DOE Office of Scientific and Technical Information (OSTI.GOV)
Berger, Jason E.
Sandia National Laboratories (SNL) has been tasked with the design of a modern transportable container (MTC) for use in high reliability transportation environments. The container is required to transport cargo capable of generating its own heat and operate under the United States’ climatic extremes. In response to these requirements, active heating and cooling is necessary to maintain a controlled environment inside the container. The following thesis project documents the design of an active heating, active cooling, and combined active heating and cooling system (now referred to as active heating and cooling systems) through computational thermal analyses, scoping of commercial systemmore » options, and mechanical integration with the container’s structure.« less
Hamblin, John; Stefanova, Katia; Angessa, Tefera Tolera
2014-01-01
Reduced levels of leaf chlorophyll content per unit leaf area in crops may be of advantage in the search for higher yields. Possible reasons include better light distribution in the crop canopy and less photochemical damage to leaves absorbing more light energy than required for maximum photosynthesis. Reduced chlorophyll may also reduce the heat load at the top of canopy, reducing water requirements to cool leaves. Chloroplasts are nutrient rich and reducing their number may increase available nutrients for growth and development. To determine whether this hypothesis has any validity in spring wheat requires an understanding of genotypic differences in leaf chlorophyll content per unit area in diverse germplasm. This was measured with a SPAD 502 as SPAD units. The study was conducted in series of environments involving up to 28 genotypes, mainly spring wheat. In general, substantial and repeatable genotypic variation was observed. Consistent SPAD readings were recorded for different sampling positions on leaves, between different leaves on single plant, between different plants of the same genotype, and between different genotypes grown in the same or different environments. Plant nutrition affected SPAD units in nutrient poor environments. Wheat genotypes DBW 10 and Transfer were identified as having consistent and contrasting high and low average SPAD readings of 52 and 32 units, respectively, and a methodology to allow selection in segregating populations has been developed.
NASA Astrophysics Data System (ADS)
1980-11-01
The Magma Cooling Tower (MCT) process utilizes a falling film heat exchanger integrated into an induced draft cooling tower to evaporate waste water. A hot water source such as return cooling water provides the energy for evaporation. Water quality control is maintained by removing potential scaling constituents to make concentrations of the waste water possible without scaling heat transfer surfaces. A pilot-scale demonstration test of the MCT process was performed from March 1979 through June 1979 at Nevada Power Company's Sunrise Station in Las Vegas, Nevada. The pilot unit extracted heat from the powerplant cooling system to evaporate cooling tower blowdown. Two water quality control methods were employed: makeup/sidestream softening and fluidized bed crystallization. The 11 week softening mode test was successful.
RS-600 programmable controller: Solar heating and cooling
NASA Technical Reports Server (NTRS)
1978-01-01
Three identical microprocessor control subsystems were developed which can be used in heating, heating and cooling, and/or hot water systems for single family, multifamily, or commercial applications. The controller incorporates a low cost, highly reliable (all solid state) microprocessor which can be easily reprogrammed.
24 CFR 3280.714 - Appliances, cooling.
Code of Federal Regulations, 2010 CFR
2010-04-01
... Systems § 3280.714 Appliances, cooling. (a) Every air conditioning unit or a combination air conditioning...) Mechanical air conditioners shall be rated in accordance with the ARI Standard 210/240-89 Unitary Air Conditioning and Air Source Unitary Heat Pump Equipment and certified by ARI or other nationally recognized...
24 CFR 3280.714 - Appliances, cooling.
Code of Federal Regulations, 2011 CFR
2011-04-01
... Systems § 3280.714 Appliances, cooling. (a) Every air conditioning unit or a combination air conditioning...) Mechanical air conditioners shall be rated in accordance with the ARI Standard 210/240-89 Unitary Air Conditioning and Air Source Unitary Heat Pump Equipment and certified by ARI or other nationally recognized...
Farmer, Joseph C
2013-12-24
A solar-powered adsorption-desorption refrigeration and air conditioning system uses nanostructural materials made of high specific surface area adsorption aerogel as the adsorptive media. Refrigerant molecules are adsorbed on the high surface area of the nanostructural material. A circulation system circulates refrigerant from the nanostructural material to a cooling unit.
NASA Astrophysics Data System (ADS)
Wang, H. C.; Chen, G. F.; Gong, M. Q.; Li, X.
2017-12-01
Thermodynamic performance comparison of single-stage mixed-refrigerant Joule-Thomson cycle (MJTR) and pure refrigerant reverse Brayton cycle (RBC) for cooling 80 to 120 K temperature-distributed heat loads was conducted in this paper. Nitrogen under various liquefaction pressures was employed as the heat load. The research was conducted under nonideal conditions by exergy analysis methods. Exergy efficiency and volumetric cooling capacity are two main evaluation parameters. Exergy loss distribution in each process of refrigeration cycle was also investigated. The exergy efficiency and volumetric cooling capacity of MJTR were obviously superior to RBC in 90 to 120 K temperature zone, but still inferior to RBC at 80 K. The performance degradation of MJTR was caused by two main reasons: The high fraction of neon resulted in large entropy generation and exergy loss in throttling process. Larger duty and WLMTD lead to larger exergy losses in recuperator.
Optimization Strategies for Single-Stage, Multi-Stage and Continuous ADRs
NASA Technical Reports Server (NTRS)
Shirron, Peter J.
2014-01-01
Adiabatic Demagnetization Refrigerators (ADR) have many advantages that are prompting a resurgence in their use in spaceflight and laboratory applications. They are solid-state coolers capable of very high efficiency and very wide operating range. However, their low energy storage density translates to larger mass for a given cooling capacity than is possible with other refrigeration techniques. The interplay between refrigerant mass and other parameters such as magnetic field and heat transfer points in multi-stage ADRs gives rise to a wide parameter space for optimization. This paper first presents optimization strategies for single ADR stages, focusing primarily on obtaining the largest cooling capacity per stage mass, then discusses the optimization of multi-stage and continuous ADRs in the context of the coordinated heat transfer that must occur between stages. The goal for the latter is usually to obtain the largest cooling power per mass or volume, but there can also be many secondary objectives, such as limiting instantaneous heat rejection rates and producing intermediate temperatures for cooling of other instrument components.
NASA Technical Reports Server (NTRS)
Lecuyer, M. R.; Hanus, G. J.
1976-01-01
An experimental study of gas film cooling was conducted on a 3X size model turbine vane. Injection in the leading edge region was from a single row of holes angled in a spanwise direction. Measurements of the local heat flux downstream from the row of coolant holes, both with and without film coolant flow, were used to determine the film cooling performance presented in terms of the Stanton number ratio. Results for a range of coolant blowing ratio, M = 0 to 2.0, indicate a reduction in heat flux of up to 15 to 30 percent at a point 10 to 11 hole diameters downstream from injection. An optimum coolant blowing ratio corresponds to a coolant-to-freestream velocity ratio in the range of 0.5. The shallow injection angle resulted in superior cooling performance for injection closest to stagnation, while the effect of injection angle was insignificant for injection further from stagnation.
Vulnerability of US and European electricity supply to climate change
NASA Astrophysics Data System (ADS)
van Vliet, Michelle T. H.; Yearsley, John R.; Ludwig, Fulco; Vögele, Stefan; Lettenmaier, Dennis P.; Kabat, Pavel
2012-09-01
In the United States and Europe, at present 91% and 78% (ref. ) of the total electricity is produced by thermoelectric (nuclear and fossil-fuelled) power plants, which directly depend on the availability and temperature of water resources for cooling. During recent warm, dry summers several thermoelectric power plants in Europe and the southeastern United States were forced to reduce production owing to cooling-water scarcity. Here we show that thermoelectric power in Europe and the United States is vulnerable to climate change owing to the combined impacts of lower summer river flows and higher river water temperatures. Using a physically based hydrological and water temperature modelling framework in combination with an electricity production model, we show a summer average decrease in capacity of power plants of 6.3-19% in Europe and 4.4-16% in the United States depending on cooling system type and climate scenario for 2031-2060. In addition, probabilities of extreme (>90%) reductions in thermoelectric power production will on average increase by a factor of three. Considering the increase in future electricity demand, there is a strong need for improved climate adaptation strategies in the thermoelectric power sector to assure futureenergy security.
NASA Astrophysics Data System (ADS)
Redfern, Andrew; Koplow, Michael; Wright, Paul
2007-01-01
Most residential heating, ventilating, and air-conditioning (HVAC) systems utilize a single zone for conditioning air throughout the entire house. While inexpensive, these systems lead to wide temperature distributions and inefficient cooling due to the difference in thermal loads in different rooms. The end result is additional cost to the end user because the house is over conditioned. To reduce the total amount of energy used in a home and to increase occupant comfort there is a need for a better control system using multiple temperature zones. Typical multi-zone systems are costly and require extensive infrastructure to function. Recent advances in wireless sensor networks (WSNs) have enabled a low cost drop-in wireless vent register control system. The register control system is controlled by a master controller unit, which collects sensor data from a distributed wireless sensor network. Each sensor node samples local settings (occupancy, light, humidity and temperature) and reports the data back to the master control unit. The master control unit compiles the incoming data and then actuates the vent resisters to control the airflow throughout the house. The control system also utilizes a smart thermostat with a movable set point to enable the user to define their given comfort levels. The new system can reduce the run time of the HVAC system and thus decreasing the amount of energy used and increasing the comfort of the home occupations.
Space Cooling in the United States: A Market Deep Dive
Baxter, Van D.; Sikes, Karen; Khowailed, Gannate
2016-01-01
The American space cooling market is experiencing stricter efficiency standards, prosperous economic conditions, a steadily recovering housing market, population migration shift to warmer climates, and declining electricity prices. These factors have yielded a climate conducive to growth in air conditioning (AC) and air source heat pump (HP) shipments in the recent past with total AC and HP shipments in 2015 accounting for 6.8 million units, showing a growth of 32 % relative to 2010. In this article, the authors investigate the impact that regulatory changes and economic changes have had on unit shipments and identify future market influencers, including themore » introduction of advanced HVAC technologies and transition to more environmentally friendly refrigerants.« less
Low-thrust Isp sensitivity study
NASA Technical Reports Server (NTRS)
Schoenman, L.
1982-01-01
A comparison of the cooling requirements and attainable specific impulse performance of engines in the 445 to 4448N thrust class utilizing LOX/RP-1, LOX/Hydrogen and LOX/Methane propellants is presented. The unique design requirements for the regenerative cooling of low-thrust engines operating at high pressures (up to 6894 kPa) were explored analytically by comparing single cooling with the fuel and the oxidizer, and dual cooling with both the fuel and the oxidizer. The effects of coolant channel geometry, chamber length, and contraction ratio on the ability to provide proper cooling were evaluated, as was the resulting specific impulse. The results show that larger contraction ratios and smaller channels are highly desirable for certain propellant combinations.
NASA Astrophysics Data System (ADS)
Worwood, Daniel; Kellner, Quirin; Wojtala, Malgorzata; Widanage, W. D.; McGlen, Ryan; Greenwood, David; Marco, James
2017-04-01
Conventional cooling approaches that target either a singular tab or outer surface of common format cylindrical lithium-ion battery cells suffer from a high cell thermal resistance. Under an aggressive duty cycle, this resistance can result in the formation of large in-cell temperature gradients and high hot spot temperatures, which are known to accelerate ageing and further reduce performance. In this paper, a novel approach to internal thermal management of cylindrical battery cells to lower the thermal resistance for heat transport through the inside of the cell is investigated. The effectiveness of the proposed method is analysed for two common cylindrical formats when subject to highly aggressive electrical loading conditions representative of a high performance electric vehicle (EV) and hybrid electric vehicle (HEV). A mathematical model that captures the dominant thermal properties of the cylindrical cell is created and validated using experimental data. Results from the extensive simulation study indicate that the internal cooling strategy can reduce the cell thermal resistance by up to 67.8 ± 1.4% relative to single tab cooling, and can emulate the performance of a more complex pack-level double tab cooling approach whilst targeting cooling at a single tab.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kern, E.C. Jr.
1978-03-07
This report is organized in three sections/: solar cooling options for the new Embassy office building, electrification of Fada N' Gourma using solar photovolatic versus conventional energy systems and an overview of the potential for village solar photovoltaic energy utilization in Upper Volta. The analysis indicates that the least-cost alternative for cooling the new offices is to modify existing plans, which call for standard electric room air conditioning units, and to incorporate energy conservation measures in the building construction and operation.
NASA Astrophysics Data System (ADS)
Steyn, Gideon; Vermeulen, Christiaan
2018-05-01
An experiment was designed to study the effect of the jet direction on convective heat-transfer coefficients in single-jet gas cooling of a small heated surface, such as typically induced by an accelerated ion beam on a thin foil or specimen. The hot spot was provided using a small electrically heated plate. Heat-transfer calculations were performed using simple empirical methods based on dimensional analysis as well as by means of an advanced computational fluid dynamics (CFD) code. The results provide an explanation for the observed turbulent cooling of a double-foil, Havar beam window with fast-flowing helium, located on a target station for radionuclide production with a 66 MeV proton beam at a cyclotron facility.
Experimental Study of Vane Heat Transfer and Film Cooling at Elevated Levels of Turbulence
NASA Technical Reports Server (NTRS)
Ames, Forrest E.
1996-01-01
This report documents the results of an experimental study on the influence of high level turbulence on vane film cooling and the influence of film cooling on vane heat transfer. Three different cooling configurations were investigated which included one row of film cooling on both pressure and suction surfaces, two staggered rows of film cooling on both suction and pressure surfaces, and a shower-head cooling array. The turbulence had a strong influence on film cooling effectiveness, particularly on the pressure surface where local turbulence levels were the highest. For the single row of holes, the spanwise mixing quickly reduced centerline effectiveness levels while mixing in the normal direction was more gradual. The film cooling had a strong influence on the heat transfer in the laminar regions of the vane. The effect of film cooling on heat transfer was noticeable in the turbulent regions but augmentation ratios were significantly lower. In addition to heat transfer and film cooling, velocity profiles were taken downstream of the film cooling rows at three spanwise locations. These profile comparisons documented the strong spanwise mixing due to the high turbulence. Total pressure exit measurements were also documented for the three configurations.
Near-field interferometry of a free-falling nanoparticle from a point-like source
NASA Astrophysics Data System (ADS)
Bateman, James; Nimmrichter, Stefan; Hornberger, Klaus; Ulbricht, Hendrik
2014-09-01
Matter-wave interferometry performed with massive objects elucidates their wave nature and thus tests the quantum superposition principle at large scales. Whereas standard quantum theory places no limit on particle size, alternative, yet untested theories—conceived to explain the apparent quantum to classical transition—forbid macroscopic superpositions. Here we propose an interferometer with a levitated, optically cooled and then free-falling silicon nanoparticle in the mass range of one million atomic mass units, delocalized over >150 nm. The scheme employs the near-field Talbot effect with a single standing-wave laser pulse as a phase grating. Our analysis, which accounts for all relevant sources of decoherence, indicates that this is a viable route towards macroscopic high-mass superpositions using available technology.
Redesign of the Extravehicular Mobility Unit Airlock Cooling Loop Recovery Assembly
NASA Technical Reports Server (NTRS)
Steele, John; Elms, Theresa; Peyton, Barbara; Rector, Tony; Jennings, Mallory A.
2016-01-01
During EVA (Extravehicular Activity) 23 aboard the ISS (International Space Station) on 07/16/2013 an episode of water in the EMU (Extravehicular Mobility Unit) helmet occurred, necessitating a termination of the EVA (Extravehicular Activity) shortly after it began. The root cause of the failure was determined to be ground-processing short-comings of the ALCLR (Airlock Cooling Loop Recovery) Ion Beds which led to various levels of contaminants being introduced into the Ion Beds before they left the ground. The Ion Beds were thereafter used to scrub the failed EMU cooling water loop on-orbit during routine scrubbing operations. The root cause investigation identified several areas for improvement of the ALCLR Assembly which have since been initiated. Enhanced washing techniques for the ALCLR Ion Bed have been developed and implemented. On-orbit cooling water conductivity and pH analysis capability to allow the astronauts to monitor proper operation of the ALCLR Ion Bed during scrubbing operation is being investigation. A simplified means to acquire on-orbit EMU cooling water samples have been designed. Finally, an inherently cleaner organic adsorbent to replace the current lignite-based activated carbon, and a non-separable replacement for the separable mixed ion exchange resin are undergoing evaluation. These efforts are undertaken to enhance the performance and reduce the risk associated with operations to ensure the long-term health of the EMU cooling water circuit.
Broessner, Gregor; Beer, Ronny; Franz, Gerhard; Lackner, Peter; Engelhardt, Klaus; Brenneis, Christian; Pfausler, Bettina; Schmutzhard, Erich
2005-01-01
Introduction We report the case of a patient who developed a severe post-exertional heat stroke with consecutive multiple organ dysfunction resistant to conventional antipyretic treatment, necessitating the use of a novel endovascular device to combat hyperthermia and maintain normothermia. Methods A 38-year-old male suffering from severe heat stroke with predominant signs and symptoms of encephalopathy requiring acute admission to an intensive care unit, was admitted to a ten-bed neurological intensive care unit of a tertiary care hospital. The patient developed consecutive multiple organ dysfunction with rhabdomyolysis, and hepatic and respiratory failure. Temperature elevation was resistant to conventional treatment measures. Aggressive intensive care treatment included forced diuresis and endovascular cooling to combat hyperthermia and maintain normothermia. Results Analyses of serum revealed elevation of proinflammatory cytokines (TNF alpha, IL-6), cytokines (IL-2R), anti-inflammatory cytokines (IL-4) and chemokines (IL-8) as well as signs of rhabdomyolysis and hepatic failure. Aggressive intensive care treatment as forced diuresis and endovascular cooling (CoolGard® and CoolLine®) to combat hyperthermia and maintain normothermia were used successfully to treat this severe heat stroke. Conclusion In this case of severe heat stroke, presenting with multiple organ dysfunction and elevation of cytokines and chemokines, which was resistant to conventional cooling therapies, endovascular cooling may have contributed significantly to the reduction of body temperature and, possibly, avoided a fatal result. PMID:16285034
Redesign of the Extravehicular Mobility Unit Airlock Cooling Loop Recovery Assembly
NASA Technical Reports Server (NTRS)
Steele, John; Elms, Theresa; Peyton, Barbara; Rector, Tony; Jennings, Mallory
2016-01-01
During EVA (Extravehicular Activity) 23 aboard the ISS (International Space Station) on 07/16/2013 an episode of water in the EMU (Extravehicular Mobility Unit) helmet occurred, necessitating a termination of the EVA (Extravehicular Activity) shortly after it began. The root cause of the failure was determined to be ground-processing short-comings of the ALCLR (Airlock Cooling Loop Recovery) Ion Beds which led to various levels of contaminants being introduced into the Ion Beds before they left the ground. The Ion Beds were thereafter used to scrub the failed EMU cooling water loop on-orbit during routine scrubbing operations. The root cause investigation identified several areas for improvement of the ALCLR Assembly which have since been initiated. Enhanced washing techniques for the ALCLR Ion Bed have been developed and implemented. On-orbit cooling water conductivity and pH analysis capability to allow the astronauts to monitor proper operation of the ALCLR Ion Bed during scrubbing operation is being investigated. A simplified means to acquire on-orbit EMU cooling water samples has been designed. Finally, an inherently cleaner organic adsorbent to replace the current lignite-based activated carbon, and a non-separable replacement for the separable mixed ion exchange resin are undergoing evaluation. These efforts are undertaken to enhance the performance and reduce the risk associated with operations to ensure the long-term health of the EMU cooling water circuit.
Advanced Hybrid Cooling Loop Technology for High Performance Thermal Management
2006-06-01
and Chung, 2003; Estes and Mudawar , 1995]. Because of the pumping pressure and flow rate requirements, such pumped systems require large pumping and...United States, April 24-25, 2003. 8. Estes, K. and Mudawar , I., “Comparison of Two-Phase Electronic Cooling Using Free Jets and Sprays”, Journal of
Solar Heating and Cooling: An Economic Assessment.
ERIC Educational Resources Information Center
McGarity, Arthur E.
This study serves as an introduction to the important economic considerations that are necessary for an assessment of the potential for solar heating and cooling in the United States. The first chapter introduces the technology that is used to tap solar energy for residential and commercial applications and illustrates the potential significance…
Advances in DNA markers and breeding for warm and cool-season turfgrasses
USDA-ARS?s Scientific Manuscript database
Warm and cool-season turfgrasses are used on lawns, parks, sport fields, golf courses and along highways and have many benefits such as erosion control, soil carbon sequestration, water filtration, heat dissipation, and providing aesthetic value. Although approximately 35,850 km2 in the United State...
Low-Load Space Conditioning Needs Assessment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Puttagunta, Srikanth
Heating, ventilating, and air-conditioning (HVAC) equipment must be right-sized to ensure energy performance and comfort. With limited low-load options in the HVAC market, many new-construction housing units are being fitted with oversized equipment that creates system efficiency, comfort, and cost penalties. To bridge the gap between currently available HVAC equipment that is oversized or inefficient and the rising demand for low-load HVAC equipment in the marketplace, HVAC equipment manufacturers need to be fully aware of the needs of the multifamily building and attached single-family (duplex and townhouse) home market. Over the past decade, Steven Winter Associates, Inc. (SWA) has providedmore » certification and consulting services for hundreds of housing projects and has accrued a large pool of data that describe multifamily and attached single-family home characteristics. The U.S. Department of Energy’s Building America research team Consortium for Advanced Residential Buildings (CARB) compiled and analyzed these data to outline the characteristics of low-load dwellings such as the heating and cooling design loads.« less
Heat-transfer processes in air-cooled engine cylinders
NASA Technical Reports Server (NTRS)
Pinkel, Benjamin
1938-01-01
From a consideration of heat-transfer theory, semi-empirical expressions are set up for the transfer of heat from the combustion gases to the cylinder of an air-cooled engine and from the cylinder to the cooling air. Simple equations for the average head and barrel temperatures as functions of the important engine and cooling variables are obtained from these expressions. The expressions involve a few empirical constants, which may be readily determined from engine tests. Numerical values for these constants were obtained from single-cylinder engine tests for cylinders of the Pratt & Whitney 1535 and 1340-h engines. The equations provide a means of calculating the effect of the various engine and cooling variables on the cylinder temperatures and also of correlating the results of engine cooling tests. An example is given of the application of the equations to the correlation of cooling-test data obtained in flight.
Li, Rui; Yu, Guanglin; Azarin, Samira M; Hubel, Allison
2018-05-01
Inadequate preservation methods of human induced pluripotent stem cells (hiPSCs) have impeded efficient reestablishment of cell culture after the freeze-thaw process. In this study, we examined roles of the cooling rate, seeding temperature, and difference between cell aggregates (3-50 cells) and single cells in controlled rate freezing of hiPSCs. Intracellular ice formation (IIF), post-thaw membrane integrity, cell attachment, apoptosis, and cytoskeleton organization were evaluated to understand the different freezing responses between hiPSC single cells and aggregates, among cooling rates of 1, 3, and 10°C/min, and between seeding temperatures of -4°C and -8°C. Raman spectroscopy images of ice showed that a lower seeding temperature (-8°C) did not affect IIF in single cells, but significantly increased IIF in aggregates, suggesting higher sensitivity of aggregates to supercooling. In the absence of IIF, Raman images showed greater variation of dimethyl sulfoxide concentration across aggregates than single cells, suggesting cryoprotectant transport limitations in aggregates. The ability of cryopreserved aggregates to attach to culture substrates did not correlate with membrane integrity for the wide range of freezing parameters, indicating inadequacy of using only membrane integrity-based optimization metrics. Lower cooling rates (1 and 3°C/min) combined with higher seeding temperature (-4°C) were better at preventing IIF and preserving cell function than a higher cooling rate (10°C/min) or lower seeding temperature (-8°C), proving the seeding temperature range of -7°C to -12°C from literature to be suboptimal. Unique f-actin cytoskeletal organization into a honeycomb-like pattern was observed in postpassage and post-thaw colonies and correlated with successful reestablishment of cell culture.
Method for harvesting rare earth barium copper oxide single crystals
Todt, V.R.; Sengupta, S.; Shi, D.
1996-04-02
A method of preparing high temperature superconductor single crystals is disclosed. The method of preparation involves preparing precursor materials of a particular composition, heating the precursor material to achieve a peritectic mixture of peritectic liquid and crystals of the high temperature superconductor, cooling the peritectic mixture to quench directly the mixture on a porous, wettable inert substrate to wick off the peritectic liquid, leaving single crystals of the high temperature superconductor on the porous substrate. Alternatively, the peritectic mixture can be cooled to a solid mass and reheated on a porous, inert substrate to melt the matrix of peritectic fluid while leaving the crystals melted, allowing the wicking away of the peritectic liquid. 2 figs.
Method for harvesting rare earth barium copper oxide single crystals
Todt, Volker R.; Sengupta, Suvankar; Shi, Donglu
1996-01-01
A method of preparing high temperature superconductor single crystals. The method of preparation involves preparing precursor materials of a particular composition, heating the precursor material to achieve a peritectic mixture of peritectic liquid and crystals of the high temperature superconductor, cooling the peritectic mixture to quench directly the mixture on a porous, wettable inert substrate to wick off the peritectic liquid, leaving single crystals of the high temperature superconductor on the porous substrate. Alternatively, the peritectic mixture can be cooled to a solid mass and reheated on a porous, inert substrate to melt the matrix of peritectic fluid while leaving the crystals melted, allowing the wicking away of the peritectic liquid.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mays, Gary T; Belles, Randy; Blevins, Brandon R
2012-05-01
Oak Ridge National Laboratory (ORNL) initiated an internal National Electric Generation Siting Study, which is an ongoing multiphase study addressing several key questions related to our national electrical energy supply. This effort has led to the development of a tool, OR-SAGE (Oak Ridge Siting Analysis for power Generation Expansion), to support siting evaluations. The objective in developing OR-SAGE was to use industry-accepted approaches and/or develop appropriate criteria for screening sites and employ an array of Geographic Information Systems (GIS) data sources at ORNL to identify candidate areas for a power generation technology application. The initial phase of the study examinedmore » nuclear power generation. These early nuclear phase results were shared with staff from the Electric Power Research Institute (EPRI), which formed the genesis and support for an expansion of the work to several other power generation forms, including advanced coal with carbon capture and storage (CCS), solar, and compressed air energy storage (CAES). Wind generation was not included in this scope of work for EPRI. The OR-SAGE tool is essentially a dynamic visualization database. The results shown in this report represent a single static set of results using a specific set of input parameters. In this case, the GIS input parameters were optimized to support an economic study conducted by EPRI. A single set of individual results should not be construed as an ultimate energy solution, since US energy policy is very complex. However, the strength of the OR-SAGE tool is that numerous alternative scenarios can be quickly generated to provide additional insight into electrical generation or other GIS-based applications. The screening process divides the contiguous United States into 100 x 100 m (1-hectare) squares (cells), applying successive power generation-appropriate site selection and evaluation criteria (SSEC) to each cell. There are just under 700 million cells representing the contiguous United States. If a cell meets the requirements of each criterion, the cell is deemed a candidate area for siting a specific power generation form relative to a reference plant for that power type. Some SSEC parameters preclude siting a power plant because of an environmental, regulatory, or land-use constraint. Other SSEC assist in identifying less favorable areas, such as proximity to hazardous operations. All of the selected SSEC tend to recommend against sites. The focus of the ORNL electrical generation source siting study is on identifying candidate areas from which potential sites might be selected, stopping short of performing any detailed site evaluations or comparisons. This approach is designed to quickly screen for and characterize candidate areas. Critical assumptions supporting this work include the supply of cooling water to thermoelectric power generation; a methodology to provide an adequate siting footprint for typical power plant applications; a methodology to estimate thermoelectric plant capacity while accounting for available cooling water; and a methodology to account for future ({approx}2035) siting limitations as population increases and demands on freshwater sources change. OR-SAGE algorithms were built to account for these critical assumptions. Stream flow is the primary thermoelectric plant cooling source evaluated in this study. All cooling was assumed to be provided by a closed-cycle cooling (CCC) system requiring makeup water to account for evaporation and blowdown. Limited evaluations of shoreline cooling and the use of municipal processed water (gray) cooling were performed. Using a representative set of SSEC as input to the OR-SAGE tool and employing the accompanying critical assumptions, independent results for the various power generation sources studied were calculated.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kosonen, M.; Hakola, M.
2012-07-01
Teollisuuden Voima Oyj (TVO) is a non-listed public company founded in 1969 to produce electricity for its stakeholders. TVO is the operator of the Olkiluoto nuclear power plant. TVO follows the principle of continuous improvement in the operation and maintenance of the Olkiluoto plant units. The PELE project (Plant Efficiency Improvement and Lifetime Extension), mainly completed during the annual outages in 2010 and 2011, and forms one part of the systematic development of Olkiluoto units. TVO maintains a long-term development program that aims at systematically modernizing the plant unit systems and equipment based on the latest technology. According to themore » program, the Olkiluoto 1 and Olkiluoto 2 plant units are constantly renovated with the intention of keeping them safe and reliable, The aim of the modernization projects is to improve the safety, reliability, and performance of the plant units. PELE project at Olkiluoto 1 was done in 2010 and at Olkiluoto 2 in 2011. The outage length of Olkiluoto 1 was 26 d 12 h 4 min and Olkiluoto 2 outage length was 28 d 23 h 46 min. (Normal service-outage is about 14 days including refueling and refueling-outage length is about seven days. See figure 1) The PELE project consisted of several single projects collected into one for coordinated project management. Some of the main projects were as follows: - Low pressure turbines: rotor, stator vane, casing and turbine instrumentation replacement. - Replacement of Condenser Cooling Water (later called seawater pumps) pumps - Replacement of inner isolation valves on the main steam lines. - Generator and the generator cooling system replacement. - Low voltage switchgear replacement. This project will continue during future outages. PELE was a success. 100 TVO employees and 1500 subcontractor employees participated in the project. The execution of the PELE projects went extremely well during the outages. The replacement of the low pressure turbines and seawater pumps improved the efficiency of the plant units, and a power increase of nearly 20 MW was achieved at both plant units. PELE wonderfully manifests one of the strategic goals of our company; developing the competence of our in-house personnel by working in projects. (authors)« less
Wheat rusts in the United States in 2015
USDA-ARS?s Scientific Manuscript database
In 2015 wheat stripe rust caused by Puccinia striiformis f. sp. graminis was widespread throughout the United States. Cool temperatures and abundant rainfall in the southern Great Plains allowed stripe rust to become widely established and spread throughout the Great Plains and eastern United States...
Wheat rusts in the United States in 2016
USDA-ARS?s Scientific Manuscript database
In 2016, wheat stripe rust caused by Puccinia striiformis f. sp. graminis was widespread throughout the United States. Cool temperatures and abundant rainfall in the southern Great Plains allowed stripe rust to become widely established and spread throughout the Great Plains and eastern United State...
Recent Developments in Microwave Ion Clocks
NASA Astrophysics Data System (ADS)
Prestage, John D.; Tjoelker, Robert L.; Maleki, Lute
We review the development of microwave-frequency standards based on trapped ions. Following two distinct paths, microwave ion clocks have evolved greatly in the last twenty years since the earliest Paul-trap-based units. Laser-cooled ion frequency standards reduce the second-order Doppler shift from ion micromotion and thermal secular motion achieving good signal-to-noise ratios via cycling transitions where as many as ~10^8 photons per second per ion may be scattered. Today, laser-cooled ion standards are based on linear Paul traps which hold ions near the node line of the trapping electric field, minimizing micromotion at the trapping-field frequency and the consequent second-order Doppler frequency shift. These quadrupole (radial) field traps tightly confine tens of ions to a crystalline single-line structure. As more ions are trapped, space charge forces some ions away from the node-line axis and the second-order Doppler effect grows larger, even at negligibly small secular temperatures. Buffer-gas-cooled clocks rely on large numbers of ions, typically ~10^7, optically pumped by a discharge lamp at a scattering rate of a few photons per second per ion. To reduce the second-order Doppler shift from space charge repulsion of ions from the trap node line, novel multipole ion traps are now being developed where ions are weakly bound with confining fields that are effectively zero through the trap interior and grow rapidly near the trap electrode ``walls''.
Physical and Thermal Structure of the Bishop Tuff, California
NASA Astrophysics Data System (ADS)
Wilson, C. J.; Hildreth, W.
2001-12-01
The 0.76 Ma Bishop Tuff, California, includes an ignimbrite constructed from a series of overlapping packages of material erupted sequentially and simultaneously from multiple sources around the ring fracture of Long Valley caldera (Wilson, C.J.N., Hildreth, W., 1997, Journal of Geology 105, 407-439). Exceptionally good continuous exposures of the ignimbrite in the walls of Owens Gorge to the east of Long Valley provide a cross-section through the east-side packages (Ig1E and Ig2E). We have measured 10 sections up the gorge walls to draw up a cross section of the ignimbrite down Owens Gorge, using lithic abundances and lithologies to define the physical eruptive packages and their subdivisions, and measurements of tuff bulk density (as an easily measured proxy for welding intensity) to define the thermal eruptive packages. The physically emplaced bodies of ignimbrite represent an overlapping, shingling suite of material such that successively later ignimbrite occurs most prominently farther away from source. Two major and two lesser zones of maximum density (welding) are present, the lower two (in Ig1Ea and lower Ig1Eb) in upper Owens Gorge, and the two most prominent (upper Ig1Eb and Ig2Eb) in middle and lower parts of the gorge. Welding fluctuations are controlled by bulk temperatures of individual batches of hotter and cooler material, but the intensity of the welding also depends on deposit thickness (i.e. load stress). Physically defined contacts between ignimbrite packages show that time breaks inferred to be of hours may not result in formation of any visible parting or flow unit boundary. Furthermore, positions of density (welding) minima between zones of higher density tuff do not coincide with horizons of stratigraphic significance. These observations lead to two conclusions. (1) The absence of clear partings or flow unit boundaries in an ignimbrite sequence is not diagnostic either of the material representing a single flow unit, or of the material being continuously progressively aggraded. (2) Use of the density (welding) minimum to locate the boundaries of cooling units and in measuring and modelling the emplacement and thermal history of compound cooling units may lead to errors.
1989-06-01
coefficients vortex circulation, symbols used in vorticity plots representing circulation values derived from different vortex core models injection...derived from different vortex core models dimensionless core size parameter: t wice the a verage core radius divided by t h e i n jection hole...Wall Heating, xjd=109.2, m=0.5, Single Injection Hole Vortex w, Temp. Difference Range (.5- 2.5) degree s 91. Local Temperature Distribution
Thermodynamic effects of single-qubit operations in silicon-based quantum computing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lougovski, Pavel; Peters, Nicholas A.
Silicon-based quantum logic is a promising technology to implement universal quantum computing. It is widely believed that a millikelvin cryogenic environment will be necessary to accommodate silicon-based qubits. This prompts a question of the ultimate scalability of the technology due to finite cooling capacity of refrigeration systems. In this work, we answer this question by studying energy dissipation due to interactions between nuclear spin impurities and qubit control pulses. Furthermore, we demonstrate that this interaction constrains the sustainable number of single-qubit operations per second for a given cooling capacity.
Thermodynamic effects of single-qubit operations in silicon-based quantum computing
Lougovski, Pavel; Peters, Nicholas A.
2018-05-21
Silicon-based quantum logic is a promising technology to implement universal quantum computing. It is widely believed that a millikelvin cryogenic environment will be necessary to accommodate silicon-based qubits. This prompts a question of the ultimate scalability of the technology due to finite cooling capacity of refrigeration systems. In this work, we answer this question by studying energy dissipation due to interactions between nuclear spin impurities and qubit control pulses. Furthermore, we demonstrate that this interaction constrains the sustainable number of single-qubit operations per second for a given cooling capacity.
2012-08-01
processed through the powder metallurgy route and develops a polycrystalline microstructure consisting of γ grains with nanoscale γ’ precipitates...on the cooling rate employed. Faster cooling rates, such as those encountered during water quenching the alloy from the high temperature single γ...and the first generation γ’ precipitates. Subsequently on quenching to a lower temperature a second generation of γ’ precipitates are formed that are
Apparatus for laser slowing and cooling of molecules
2016-10-09
cooling of a new molecular species, TlF. We have also successfully acquired and assembled the parts for a custom laser system, which produces long...preliminary work on laser cooling of a new molecular species, TlF. We have also successfully acquired and assembled the parts for a custom laser system, which... custom laser system, which produces long (~200 microsecond), single-frequency pulses with energy ~1.1 Joules at 1064 nm and/or ~0.4 Joules at 532 nm
NASA Astrophysics Data System (ADS)
Bulman, Gary; Siivola, Ed; Wiitala, Ryan; Grant, Brian; Pierce, Jonathan; Venkatasubramanian, Rama
2007-03-01
Thin film superlattice (SL) based thermoelectric (TE) devices offer the potential for improved efficiency and high heat flux cooling over conventional bulk materials. Recently, we have demonstrated external cooling of 55K and heat pumping capacity of 128 W/cm^2. These high heat fluxes in thin film devices, while attractive for cooling hot-spots in electronics, also make the device performance sensitive to various thermal resistances in the device structure. We will discuss advances in the cooling performance of Bi2Te3-based SL TE devices and describe a method to extract device material parameters, including thermal resistance, from measurements of their δT-I-V characteristics. These parameters will be compared to values obtained through Hall and Seebeck coefficient measurement on epitaxial materials. Results will be presented for both single couple and multi-couple modules, as well as multi-stage cascaded devices made with these materials. Single stage cooling couples with δTmax of 57.8K (Tc˜242K) and multi-stage modules with δTmax˜92.2K (Tc˜209K) have been measured. G.E. Bulman, E. Siivola, B. Shen and R. Venkatasubramanian, Appl. Phys. Lett. 89, 122117 (2006).
New Research on the Cowling and Cooling of Radial Engines
NASA Technical Reports Server (NTRS)
Molloy, Richard C.; Brewster, James H., III
1943-01-01
An extensive series of wind-tunnel tests on a half-scale conventional, nacelle model were made by the United Aircraft Corporation to determine and correlate the effects of many variables on cooling air flow and nacelle drag. The primary investigation was concerned with the reaction of these factors to varying conditions ahead of, across, and behind the engine. In the light of this investigation, common misconceptions and factors which are frequently overlooked in the cooling and cowling of radial engines are considered in some detail. Data are presented to support certain design recommendations and conclusions which should lead toward the improvement of present engine installations. Several charts are included to facilitate the estimation of cooling drag, available cooling pressure, and cowl exit area.
Preliminary study of TEC application in cooling system
NASA Astrophysics Data System (ADS)
Sulaiman, A. C.; Amin, N. A. M.; Saidon, M. S.; Majid, M. S. A.; Rahman, M. T. A.; Kazim, M. N. F. M.
2017-10-01
Integration of thermoelectric cooling (TEC) within a space cooling system in the lecturer room is studied. The studied area (air conditioned surrounding) is encapsulated with wall, floor, roof, and glass window. TEC module is placed on the glass window. The prototype of the studied compartment is designed using cabin container. The type and number of TEC module are studied and the effects on the cooling performance are analyzed as it is assumed to be tested within an air conditioned lecturer room. The experimental and mathematical modeling of the cooling system developed. It is expected that the mathematical modeling derived from this study will be used to estimate the use of the number of TEC module to be integrated with air conditioner unit where possible.
Twelve solar-heating/cooling systems: Design and development
NASA Technical Reports Server (NTRS)
1980-01-01
Two quarterly reports describe first 6 months of development on single family, multifamily, and commercial installations in Minneapolis area. Reports discuss basic requirements, and reasons for selecting specific configurations. Systems consist of liquid cooled flat plate collectors, two fluid loops, and gas-fired forced-air auxiliary heat source.
NASA Technical Reports Server (NTRS)
1978-01-01
Progress in the development, fabrication, and delivery of solar subsystems consisting of a solar operated pump, and solar collectors which can be used in solar heating and cooling, or hot water, for single family, multifamily, or commercial applications is reported.
Studies of the Twin Helix Parametric-resonance Ionization Cooling Channel with COSY INFINITY
DOE Office of Scientific and Technical Information (OSTI.GOV)
J.A. Maloney, K.B. Beard, R.P. Johnson, A. Afanasev, S.A. Bogacz, Y.S. Derbenev, V.S. Morozov, B. Erdelyi
2012-07-01
A primary technical challenge to the design of a high luminosity muon collider is an effective beam cooling system. An epicyclic twin-helix channel utilizing parametric-resonance ionization cooling has been proposed for the final 6D cooling stage. A proposed design of this twin-helix channel is presented that utilizes correlated optics between the horizontal and vertical betatron periods to simultaneously focus transverse motion of the beam in both planes. Parametric resonance is induced in both planes via a system of helical quadrupole harmonics. Ionization cooling is achieved via periodically placed wedges of absorbing material, with intermittent rf cavities restoring longitudinal momentum necessarymore » to maintain stable orbit of the beam. COSY INFINITY is utilized to simulate the theory at first order. The motion of particles around a hyperbolic fixed point is tracked. Comparison is made between the EPIC cooling channel and standard ionization cooling effects. Cooling effects are measured, after including stochastic effects, for both a single particle and a distribution of particles.« less
Combined refrigeration system with a liquid pre-cooling heat exchanger
Gaul, Christopher J.
2003-07-01
A compressor-pump unit for use in a vapor-compression refrigeration system is provided. The compressor-pump unit comprises a driving device including a rotatable shaft. A compressor is coupled with a first portion of the shaft for compressing gaseous refrigerant within the vapor-compression refrigeration system. A liquid pump is coupled with a second portion of the shaft for receiving liquid refrigerant having a first pressure and for discharging the received liquid refrigerant at a second pressure with the second pressure being higher than the first pressure by a predetermined amount such that the discharged liquid refrigerant is subcooled. A pre-cooling circuit is connected to the liquid pump with the pre-cooling circuit being exposed to the gaseous refrigerant whereby the gaseous refrigerant absorbs heat from the liquid refrigerant, prior to the liquid refrigerant entering the liquid pump.
Gerstl, N; Youssef, C; Cardona, F; Klebermass-Schrehof, K; Grill, A; Weninger, M; Berger, A; Olischar, M
2015-01-01
Therapeutic hypothermia (HT) has been shown to reduce the risk of death or disability and increase the rate of survival free of -disability at 18-24 months of age in hypoxic-ischemic encephalopathy (HIE). The aim of this study was to take a national survey which (a) evaluated the practice of therapeutic HT for perinatal asphyxia in Austria, (b) evaluated the current clinical management of neonatal HIE and (c) evaluated the need for a national perinatal asphyxia and HT registry. In January 2013, a questionnaire was sent out to the clinical heads of all neonatal level-II and level-III units in Austria. We received replies from all 30 level II and level III units in Austria (response rate 100%). 19 units (63%) answered that they applied HT, 11 units (37%) said they transferred patients for cooling to other units, 3 of those 11 units (27%) said they applied cooling during transport. 25 units (83%) felt the necessity to establish a national registry. The results of this survey show that there is already a high implementation of therapeutic HT in Austria, but there remains a need for information, awareness and training. Problem areas tend to be in the transport of asphyxiated neonates, brain monitoring during cooling and follow-up of affected patients. We believe, that the establishment of national guidelines and a national register could increase awareness for the importance of therapeutic HT in neonatal HIE, thus improve the Austrian management of those infants. © Georg Thieme Verlag KG Stuttgart · New York.
Evaporative cooling for Holstein dairy cows under grazing conditions
NASA Astrophysics Data System (ADS)
Valtorta, Silvia E.; Gallardo, Miriam R.
. Twenty-four grazing Holstein cows in mid and late lactation were randomly assigned to two treatment groups: control and cooled. The trial was performed at the Experimental Dairy Unit, Rafaela Agricultural Experimental Station (INTA), Argentina. The objective was to evaluate the effects of sprinkler and fan cooling before milkings on milk production and composition. The effects of the cooling system on rectal temperature and respiration rate were also evaluated. Cooled cows showed higher milk production (1.04 l cow-1 day-1). The concentration and yield of milk fat and protein increased in response to cooling treatment. The cooling system also reduced rectal temperature and respiration rate. No effects were observed on body condition. It was concluded that evaporative cooling, which is efficient for housed animals, is also appropriate to improve yields and animal well-being under grazing systems. These results are impressive since the cooling system was utilized only before milkings, in a system where environmental control is very difficult to achieve. This trial was performed during a mild summer. The results would probably be magnified during hotter weather.
Zhai, Haibo; Rubin, Edward S
2016-04-05
Advanced cooling systems can be deployed to enhance the resilience of thermoelectric power generation systems. This study developed and applied a new power plant modeling option for a hybrid cooling system at coal- or natural-gas-fired power plants with and without amine-based carbon capture and storage (CCS) systems. The results of the plant-level analyses show that the performance and cost of hybrid cooling systems are affected by a range of environmental, technical, and economic parameters. In general, when hot periods last the entire summer, the wet unit of a hybrid cooling system needs to share about 30% of the total plant cooling load in order to minimize the overall system cost. CCS deployment can lead to a significant increase in the water use of hybrid cooling systems, depending on the level of CO2 capture. Compared to wet cooling systems, widespread applications of hybrid cooling systems can substantially reduce water use in the electric power sector with only a moderate increase in the plant-level cost of electricity generation.
Implementation of a Legionella Ordinance for Multifamily Housing, Garland, Texas
Whitney, Ellen A.; Blake, Sarah
2017-01-01
Context: The incidence of legionellosis has sharply increased in the United States as a result of contaminated water systems. Jurisdictions across the country are considering whether to develop and implement regulations to protect individuals against Legionnaires' disease with its associated high morbidity and mortality. Objective: This article sheds light on the implementation and effectiveness of a 2005 citywide Legionella testing mandate of multifamily housing cooling towers in Garland, Texas. This ordinance has been in place for more than 10 years and represents the first of its kind in the United States to mandate routine testing of cooling towers for Legionella in multifamily housing. Design, Setting, and Population: We utilized a mix of both qualitative and quantitative methods to explore the development, adoption, and implementation of the ordinance. Phone interviews were conducted with individuals from the City of Garland Health Department and apartment managers. Quantitative data included public health surveillance data on legionellosis. Main Outcome Measures: Barriers and facilitators of implementation, number and percentage of cooling towers from multifamily housing units that tested positive for Legionella by year, and number of legionellosis cases by year in Garland, Texas. Results: Study outcomes highlight key themes that facilitated the successful implementation of the Legionella testing mandate, including the importance of timing, leadership support, stakeholder engagement, and education and outreach. The number of contaminated cooling towers was reduced over time. Conclusion: Mandatory monitoring for legionella in a local jurisdiction may result in reduced risk of legionellosis from cooling towers through raising awareness and education of building owners and managers about the need to prevent, detect, and remediate legionella contamination in their building water systems. Garland, Texas, broke new ground in the United States in moving toward primary prevention of legionellosis. The ordinance may be useful both in serving to educate and increase awareness about the need for Legionella prevention and to monitor effectiveness of maintenance procedures. PMID:28141673
Composite casting/bonding construction of an air-cooled, high temperature radial turbine wheel
NASA Technical Reports Server (NTRS)
Hammer, A. N.; Aigret, G.; Rodgers, C.; Metcalfe, A. G.
1983-01-01
A composite casting/bonding technique has been developed for the fabrication of a unique air-cooled, high temperature radial inflow turbine wheel design applicable to auxilliary power units with small rotor diameters and blade entry heights. The 'split blade' manufacturing procedure employed is an alternative to complex internal ceramic coring. Attention is given to both aerothermodynamic and structural design, of which the latter made advantageous use of the exploration of alternative cooling passage configurations through CAD/CAM system software modification.
A Comparison of Film Cooling Techniques in a High Speed, True Scale, Fully Cooled Turbine Vane Ring
2007-06-01
configurations in a true scale turbine vane for three proprietary airfoil designs. The measurements for this study were taken at the United States Air...and Background Gas Turbine Film Cooling Gas turbine engines have become an integral part of our society as we use them to propel our aircraft ...and naval vessels as well as generate electricity. Ever since Frank Whittle first applied for a patent on his turbojet engine in 1929, turbine
NASA Technical Reports Server (NTRS)
Wernet, Mark P.; Georgiadis, Nicholas J.; Locke, Randy J.
2018-01-01
Film cooling is used in a wide variety of engineering applications for protection of surfaces from hot or combusting gases. The design of more efficient thin film cooling geometries/configurations could be facilitated by an ability to accurately model and predict the effectiveness of current designs using computational fluid dynamics (CFD) code predictions. Hence, a benchmark set of flow field property data were obtained for use in assessing current CFD capabilities and for development of better turbulence models. Both Particle Image Velocimetry (PIV) and spontaneous rotational Raman scattering (SRS) spectroscopy were used to acquire high quality, spatially-resolved measurements of the mean velocity, turbulence intensity and also the mean temperature and normalized root mean square (rms) temperatures in a single injector cooling flow arrangement. In addition to flowfield measurements, thermocouple measurements on the plate surface enabled estimates of the film effectiveness. Raman spectra in air were obtained across a matrix of radial and axial locations downstream from a 68.07 mm square nozzle blowing heated air over a range of temperatures and Mach numbers, across a 30.48 cm long plate equipped with a single injector cooling hole. In addition, both centerline streamwise 2-component PIV and cross-stream 3-component Stereo PIV data at 15 axial stations were collected in the same flows. The velocity and temperature data were then compared against Wind-US CFD code predictions for the same flow conditions. The results of this and planned follow-on studies will support NASA's development and assessment of turbulence models for heated flows.
NASA Technical Reports Server (NTRS)
Wernet, Mark P.; Georgiadis, Nicholas J.; Locke, Randy J.
2018-01-01
Film cooling is used in a wide variety of engineering applications for protection of surfaces from hot or combusting gases. The design of more efficient thin film cooling geometries/configurations could be facilitated by an ability to accurately model and predict the effectiveness of current designs using computational fluid dynamics (CFD) code predictions. Hence, a benchmark set of flow field property data were obtained for use in assessing current CFD capabilities and for development of better turbulence models. Both Particle Image Velocimetry (PIV) and spontaneous rotational Raman scattering (SRS) spectroscopy were used to acquire high quality, spatially-resolved measurements of the mean velocity, turbulence intensity and also the mean temperature and normalized root mean square (rms) temperatures in a single injector cooling flow arrangement. In addition to flowfield measurements, thermocouple measurements on the plate surface enabled estimates of the film effectiveness. Raman spectra in air were obtained across a matrix of radial and axial locations downstream from a 68.07 mm square nozzle blowing heated air over a range of temperatures and Mach numbers, across a 30.48cm long plate equipped with a single injector cooling hole. In addition, both centerline streamwise 2-component PIV and cross-stream 3-component Stereo PIV data at 15 axial stations were collected in the same flows. The velocity and temperature data were then compared against Wind-US CFD code predictions for the same flow conditions. The results of this and planned follow-on studies will support NASA's development and assessment of turbulence models for heated flows.
Heat transfer from an internal combustion (Otto-cycle) engine on the surface of Mars
NASA Technical Reports Server (NTRS)
Gwynne, Owen
1992-01-01
The cooling requirements for an average car sized engine (spark-ignition, V-6, four-stroke, naturally aspirated, about 200 kg, about 100 kW) were looked at for Mars. Several modes of cooling were considered, including forced convection, exhaust, radiation and closed loop systems. The primary goal was to determine the effect of the thinner Martian atmosphere on the cooling system. The results show that there was only a 6-percent difference in the cooling requirements. This difference was due mostly to the thinner atmosphere during forced convection and the heat capacity of the exhaust. A method using a single pass counter-flow heat exchanger is suggested to offset this difference in cooling requirements.
Heat transfer from an internal combustion (Otto-cycle) engine on the surface of Mars
NASA Astrophysics Data System (ADS)
Gwynne, Owen
1992-05-01
The cooling requirements for an average car sized engine (spark-ignition, V-6, four-stroke, naturally aspirated, about 200 kg, about 100 kW) were looked at for Mars. Several modes of cooling were considered, including forced convection, exhaust, radiation and closed loop systems. The primary goal was to determine the effect of the thinner Martian atmosphere on the cooling system. The results show that there was only a 6-percent difference in the cooling requirements. This difference was due mostly to the thinner atmosphere during forced convection and the heat capacity of the exhaust. A method using a single pass counter-flow heat exchanger is suggested to offset this difference in cooling requirements.
Solar heating and cooling system installed at Leavenworth, Kansas
NASA Technical Reports Server (NTRS)
1980-01-01
A solar heating and cooling is described which is designed to furnish 90 percent of the overall heating load, 70 percent of the cooling load and 100 percent of the domestic hot water load. The building has two floors with a total of 12,000 square feet gross area. The system has 120 flat-plate liquid solar panels with a net area of 2,200 square feet. Five 3 ton Arkla solar assisted absorption units provide the cooling, in conjunction with a 3,000 gallon chilled water storage tank. Two 3,000 gallon storage tanks are provided with one designated for summer use, whereas both tanks are utilized during winter.
Cooling system for removing metabolic heat from an hermetically sealed spacesuit
NASA Technical Reports Server (NTRS)
Webbon, B. W.; Vykukal, H. C.; Williams, B. A. (Inventor)
1978-01-01
An improved cooling and ventilating system is described for removing metabolic heat, waste gases and water vapor generated by a wearer of an hermetically sealed spacesuit. The cooling system was characterized by a body suit, having a first circuit for simultaneously establishing a cooling flow of water through the thorax and head sections of the body suit. Circulation patches were included mounted in the thorax section and head section of the body suit. A second circuit for discharing a flow of gas throughout the spacesuit and a disconnect unit for coupling the circuits with a life support system externally related to the spacesuit were provided.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Jiachen; Zhang, Kai; Liu, Junfeng
Solar reflective “cool roofs” absorb less sunlight than traditional dark roofs, reducing solar heat gain, and decreasing the amount of heat transferred to the atmosphere. Widespread adoption of cool roofs could therefore reduce temperatures in urban areas, partially mitigating the urban heat island effect, and contributing to reversing the local impacts of global climate change. The impacts of cool roofs on global climate remain debated by past research and are uncertain. Using a sophisticated Earth system model, the impacts of cool roofs on climate are investigated at urban, continental, and global scales. We find that global adoption of cool roofsmore » in urban areas reduces urban heat islands everywhere, with an annual- and global-mean decrease from 1.6 to 1.2 K. Decreases are statistically significant, except for some areas in Africa and Mexico where urban fraction is low, and some high-latitude areas during wintertime. Analysis of the surface and TOA energy budget in urban regions at continental-scale shows cool roofs causing increases in solar radiation leaving the Earth-atmosphere system in most regions around the globe, though the presence of aerosols and clouds are found to partially offset increases in upward radiation. Aerosols dampen cool roof-induced increases in upward solar radiation, ranging from 4% in the United States to 18% in more polluted China. Adoption of cool roofs also causes statistically significant reductions in surface air temperatures in urbanized regions of China (0.11±0.10 K) and the United States (0.14±0.12 K); India and Europe show statistically insignificant changes. The research presented here indicates that adoption of cool roofs around the globe would lead to statistically insignificant reductions in global mean air temperature (0.0021 ±0.026 K). This counters past research suggesting that cool roofs can reduce, or even increase global mean temperatures. Thus, we suggest that while cool roofs are an effective tool for reducing building energy use in hot climates, urban heat islands, and regional air temperatures, their influence on global climate is likely negligible.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhao, Weihuan; France, David M.; Yu, Wenhua
At present, single-phase liquid, forced convection cooled heat sinks with fins are used to cool power electronics in hybrid electric vehicles (HEVs). Although use of fins in the cooling channels increases heat transfer rates considerably, a second low-temperature radiator and associated pumping system are still required in HEVs. This additional cooling system adds weight and cost while decreasing the efficiency of HEVs. With the objective of eliminating this additional low-temperature radiator and pumping system in HEVs, an alternative cooling technology, subcooled boiling in the cooling channels, was investigated in the present study. Numerical heat transfer simulations were performed using subcooledmore » boiling in the power electronics cooling channels with the coolant supplied from the existing main engine cooling system. Results show that this subcooled boiling system is capable of removing 25% more heat from the power electronics than the conventional forced convection cooling technology, or it can reduce the junction temperature of the power electronics at the current heat removal rate. With the 25% increased heat transfer option, high heat fluxes up to 250 W/cm(2) (typical for wideband-gap semiconductor applications) are possible by using the subcooled boiling system.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-18
... Cooling Method for Protective Clothing Ensembles AGENCY: Department of the Army, DoD. ACTION: Notice... Protective Clothing Ensembles,'' filed March 30, 2010. The United States Government, as represented by the... to a two- stage evaporative cooling method for use in protective clothing ensembles. Brenda S. Bowen...
Low-cost, compact, cooled photomultiplier assembly for use in magnetic fields up to 1400 Gauss
NASA Technical Reports Server (NTRS)
Patch, R. W.; Tashjian, R. A.; Jentner, T. A.
1975-01-01
Use of vortex tube for cooling and concentric shielding have produced smaller and more compact unit than was previously available. Future uses of device could include installation in gas chromatographs and mass spectrometers. Additional uses would include measurements and controls in magnetohydrodynamic power generators and fusion reactors.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jankowski, Todd Andrew; Gamboa, Jose A
Cooling devices for use with electric submersible pump motors include a refrigerator attached to the end of the electric submersible pump motor with the evaporator heat exchanger accepting all or a portion of the heat load from the motor. The cooling device can be a self-contained bolt-on unit, so that minimal design changes to existing motors are required.
External Peltier Cooler For Low-Noise Amplifier
NASA Technical Reports Server (NTRS)
Soper, Terry A.
1990-01-01
Inexpensive Peltier-effect cooling module made of few commercially available parts used to reduce thermal noise in microwave amplifier. Retrofitted to almost any microwave low-noise amplifier or receiver preamplifier used in communication, telemetry, or radar. Includes copper or aluminum cold plate held tightly against unit to be cooled by strap-type worm-gear clamps.
Apparatus and methods for supplying auxiliary steam in a combined cycle system
Gorman, William G.; Carberg, William George; Jones, Charles Michael
2002-01-01
To provide auxiliary steam, a low pressure valve is opened in a combined cycle system to divert low pressure steam from the heat recovery steam generator to a header for supplying steam to a second combined cycle's steam turbine seals, sparging devices and cooling steam for the steam turbine if the steam turbine and gas turbine lie on a common shaft with the generator. Cooling steam is supplied the gas turbine in the combined cycle system from the high pressure steam turbine. Spent gas turbine cooling steam may augment the low pressure steam supplied to the header by opening a high pressure valve whereby high and low pressure steam flows are combined. An attemperator is used to reduce the temperature of the combined steam in response to auxiliary steam flows above a predetermined flow and a steam header temperature above a predetermined temperature. The auxiliary steam may be used to start additional combined cycle units or to provide a host unit with steam turbine cooling and sealing steam during full-speed no-load operation after a load rejection.
Donahue, Suzanne; DiBlasi, Robert M; Thomas, Karen
2018-02-02
To examine the practice of nebulizer cool mist blow-by oxygen administered to spontaneously breathing postanesthesia care unit (PACU) pediatric patients during Phase one recovery. Existing evidence was evaluated. Informal benchmarking documented practices in peer organizations. An in vitro study was then conducted to simulate clinical practice and determine depth and amount of airway humidity delivery with blow-by oxygen. Informal benchmarking information was obtained by telephone interview. Using a three-dimensional printed simulation model of the head connected to a breathing lung simulator, depth and amount of moisture delivery in the respiratory tree were measured. Evidence specific to PACU administration of cool mist blow-by oxygen was limited. Informal benchmarking revealed that routine cool mist oxygenated blow-by administration was not widely practiced. The laboratory experiment revealed minimal moisture reaching the mid-tracheal area of the simulated airway model. Routine use of oxygenated cool mist in spontaneously breathing pediatric PACU patients is not supported. Copyright © 2017 American Society of PeriAnesthesia Nurses. Published by Elsevier Inc. All rights reserved.
Modeling and Economic Analysis of Power Grid Operations in a Water Constrained System
NASA Astrophysics Data System (ADS)
Zhou, Z.; Xia, Y.; Veselka, T.; Yan, E.; Betrie, G.; Qiu, F.
2016-12-01
The power sector is the largest water user in the United States. Depending on the cooling technology employed at a facility, steam-electric power stations withdrawal and consume large amounts of water for each megawatt hour of electricity generated. The amounts are dependent on many factors, including ambient air and water temperatures, cooling technology, etc. Water demands from most economic sectors are typically highest during summertime. For most systems, this coincides with peak electricity demand and consequently a high demand for thermal power plant cooling water. Supplies however are sometimes limited due to seasonal precipitation fluctuations including sporadic droughts that lead to water scarcity. When this occurs there is an impact on both unit commitments and the real-time dispatch. In this work, we model the cooling efficiency of several different types of thermal power generation technologies as a function of power output level and daily temperature profiles. Unit specific relationships are then integrated in a power grid operational model that minimizes total grid production cost while reliably meeting hourly loads. Grid operation is subject to power plant physical constraints, transmission limitations, water availability and environmental constraints such as power plant water exit temperature limits. The model is applied to a standard IEEE-118 bus system under various water availability scenarios. Results show that water availability has a significant impact on power grid economics.
Lubner, Meghan G; Hinshaw, J Louis; Andreano, Anita; Sampson, Lisa; Lee, Fred T; Brace, Christopher L
2012-03-01
To evaluate the performance of a gas-cooled, high-powered microwave system. Investigators performed 54 ablations in ex vivo bovine livers using three devices-a single 17-gauge cooled radiofrequency(RF) electrode; a cluster RF electrode; and a single 17-gauge, gas-cooled microwave (MW) antenna-at three time points (n = 6 at 4 minutes, 12 minutes, and 16 minutes). RF power was applied using impedance-based pulsing with maximum 200 W generator output. MW power of 135 W at 2.45 GHz was delivered continuously. An approved in vivo study was performed using 13 domestic pigs. Hepatic ablations were performed using single applicators and the above-mentioned MW and RF generator systems at treatment times of 2 minutes (n = 7 MW, n = 6 RF), 5 minutes (n = 23 MW, n = 8 RF), 7 minutes (n = 11 MW, n = 6 RF), and 10 minutes (n = 7 MW, n = 9 RF). Mean transverse diameter and length of the ablation zones were compared using analysis of variance (ANOVA) with post-hoc t tests and Wilcoxon rank-sum tests. Single ex vivo MW ablations were larger than single RF ablations at all time points (MW mean diameter range 3.5-4.8 cm 4-16 minutes; RF mean diameter range 2.6-3.1 cm 4-16 minutes) (P < .05). There was no difference in mean diameter between cluster RF and MW ablations (RF 3.3-4.4 cm 4-16 minutes; P = .4-.9). In vivo lesion diameters for MW (and RF) were as follows: 2.6 cm ± 0.72 (RF 1.5 cm ± 0.14), 3.6 cm ± 0.89 (RF 2.0 cm ± 0.4), 3.4 cm ± 0.87 (RF 1.8 cm ± 0.23), and 3.8 cm ± 0.74 (RF 2.1 cm ± 0.3) at 2 minutes, 5 minutes, 7 minutes, and 10 minutes (P < .05 all time points). Gas-cooled, high-powered MW ablation allows the generation of large ablation zones in short times. Copyright © 2012 SIR. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Arlensiú Ordóñez Cencerrado, Amanda; Kilian, Rolf; Díaz-Michelena, Marina
2017-04-01
Large areas of Mars and other celestial bodies are covered with basaltic lava flows and their associated craters. Depending on the individual cooling history and related single versus multi-domain status of the magnetites, as well as the global magnetic field characteristic during crystallization, such rocks could be characterized by very distinct remanent and induced magnetic signatures. Thus, a characterization of analogue craters and lava flows on Earth, and the creation of a database of their distinct magnetic parameters is of key importance for the near future exploration of planetary surfaces like Mars and the Moon. For example, three potential landing sites of the ExoMars 2020 mission include such geological scenarios. Complete on ground measurements of their distinct magnetic properties would also allow information about the characteristics of the early Martian magnetic field. As case study in the former context we selected a small crater (56°07' S, 69°42' E), which represents an agglutinated spatter cone, and its surrounding lava flows within the Pali Aike Volcano Field in Patagonia. Although the chemical composition of the basalts formed along and outside of the crater is similar, distinct local cooling, outgassing and crystallization histories are likely to produced huge differences in the magnetic signatures. With the objective to achieve a better interpretation of future more extended on ground geophysical characterization on board planetary vehicles, we performed a profound magnetic characterization of the Pali Aike crater including: • magnetic surveys with scalar, vector and gradiometric measurements providing high-resolution vector magnetic maps of the crater, • paleomagnetic data obtained from drilled oriented samples along a transect across the crater. Further laboratory data including remanence, susceptibility, coercitivity which have been also drawn in Day plots to analyse single versus multi domain status of magnetites in the basaltic ground mass, • a petrographical and chemical characterization of the magnetites by microscope and electron microprobe, • and a model that considers not exposed rock units and is able to explain the observed 3D magnetic characteristics. This could be transferred to other comparable planetary scenarios. The most important results of our investigation indicate that A vector magnetic data of rocks with highly remanent versus induced magnetic signatures high Königsberger ratios provide implications for paleofield orientations, B magnetic anomalies of up to +8000 nT can be related to different proportions of single versus multi-domain status of magnetites which reflect the local cooling histories in different sectors of the crater and its surroundings as well as on a decimeter scale within single volcanic spatter blocks and C our 3-D model is able to reproduce observed surface rock magnetic signatures together with likely signatures of underlying rock units and their spatial distribution. In the near future the above described results should be provided by a magnetic multisensor instrument combining vector and different susceptibility data as well as local demagnetization histories which is recently developed in our NEWTON EU project in advance to its inclusion on board rovers to planetary missions.
Solar heating and cooling diode module
Maloney, Timothy J.
1986-01-01
A high efficiency solar heating system comprising a plurality of hollow modular units each for receiving a thermal storage mass, the units being arranged in stacked relation in the exterior frame of a building, each of the units including a port for filling the unit with the mass, a collector region and a storage region, each region having inner and outer walls, the outer wall of the collector region being oriented for exposure to sunlight for heating the thermal storage mass; the storage region having an opening therein and the collector region having a corresponding opening, the openings being joined for communicating the thermal storage mass between the storage and collector regions by thermosiphoning; the collector region being disposed substantially below and in parallel relation to the storage region in the modular unit; and the inner wall of the collector region of each successive modular unit in the stacked relation extending over the outer wall of the storage region of the next lower modular unit in the stacked relation for reducing heat loss from the system. Various modifications and alternatives are disclosed for both heating and cooling applications.
Experimental study of the rotational magnetocaloric effect in KTm(MoO4)2
NASA Astrophysics Data System (ADS)
Tarasenko, Róbert; Tkáč, Vladimír; Orendáčová, Alžbeta; Orendáč, Martin; Feher, Alexander
2018-06-01
An experimental study is presented of the rotational magnetocaloric effect in a KTm(MoO4)2 single crystal at temperatures above 2 K associated with the rotation of a single crystal between the magnetic easy and hard axis in constant magnetic fields up to 5 T. The magnetocaloric properties of KTm(MoO4)2 single crystals are investigated by isothermal magnetization measurements. The maximal rotational entropy change -ΔSR ≈ 9.8 J/(kgK) is achieved at 10 K in a magnetic field of 5 T. The adiabatic rotation of a single crystal in a field of 5 T at an initial temperature of 4.2 K causes cooling of the sample down to 0.5 K, which indicates an interesting possibility of using this material for cooling processes at low temperatures.
NASA Astrophysics Data System (ADS)
Muthukumar, Palanisamy; Naik, Bukke Kiran; Goswami, Amarendra
2018-02-01
Mechanical draft cross flow cooling towers are generally used in a large-scale water cooled condenser based air-conditioning plants for removing heat from warm water which comes out from the condensing unit. During this process considerable amount of water in the form of drift (droplets) and evaporation is carried away along with the circulated air. In this paper, the performance evaluation of a standard cross flow induced draft cooling tower in terms of water loss, range, approach and cooling tower efficiency are presented. Extensive experimental studies have been carried out in three cooling towers employed in a water cooled condenser based 1200 TR A/C plant over a period of time. Daily variation of average water loss and cooling tower performance parameters have been reported for some selected days. The reported average water loss from three cooling towers is 4080 l/h and the estimated average water loss per TR per h is about 3.1 l at an average relative humidity (RH) of 83%. The water loss during peak hours (2 pm) is about 3.4 l/h-TR corresponding to 88% of RH and the corresponding efficiency of cooling towers varied between 25% and 45%.
Liquid cooling applications on automotive exterior LED lighting
NASA Astrophysics Data System (ADS)
Aktaş, Mehmet; Şenyüz, Tunç; Şenyıldız, Teoman; Kılıç, Muhsin
2018-02-01
In this study cooling of a LED unit with heatsink and liquid cooling block which is used in automotive head lamp applications has been investigated numerically and experimentally. Junction temperature of a LED which is cooled with heatsink and liquid cooling block obtained in the experiment. 23°C is used both in the simulation and the experiment phase. Liquid cooling block material is choosed aluminium (Al) and polyamide. All tests and simulation are performed with three different flow rate. Temperature distribution of the designed product is investigated by doing the numerical simulations with a commercially software. In the simulations, fluid flow is assumed to be steady, incompressible and laminar and 3 dimensional (3D) Navier-Stokes equations are used. According to the calculations it is obtained that junction temperature is higher in the heatsink design compared to block cooled one. By changing the block material, it is desired to investigate the variation on the LED junction temperature. It is found that more efficient cooling can be obtained in block cooling by using less volume and weight. With block cooling lifetime of LED can be increased and flux loss can be decreased with the result of decreased junction temperature.
2012-04-01
strongly depen- dent on the cooling rate employed. Faster cooling rates, such as those encountered during water quenching the alloy from the high temperature...precipitates. Subsequently on quenching to a lower temperature a second generation of c0 precipitates are formed that are considerably smaller in size and...annealing after rapid quenching of the alloy from the high temperature single c phase field. Therefore, typically these studies have focused on amonomodal
Gill, C O; Moza, L F; Badoni, M; Barbut, S
2006-07-15
The log mean numbers of aerobes, coliforms, Escherichia coli and presumptive staphylococci plus listerias on chicken carcasses and carcass portions at various stages of processing at a poultry packing plant were estimated from the numbers of those bacteria recovered from groups of 25 randomly selected product units. The fractions of listerias in the presumptive staphylococci plus listerias groups of organisms were also estimated. Samples were obtained from carcasses by excising a strip of skin measuring approximately 5 x 2 cm(2) from a randomly selected site on each selected carcass, or by rinsing each selected carcass portion. The log mean numbers of aerobes, coliforms, E. coli and presumptive staphylococci plus listerias on carcasses after scalding at 58 degrees C and plucking were about 4.4, 2.5, 2.2 and 1.4 log cfu/cm(2), respectively. The numbers of bacteria on eviscerated carcasses were similar. After the series of operations for removing the crop, lungs, kidneys and neck, the numbers of aerobes were about 1 log unit less than on eviscerated carcasses, but the numbers of the other bacteria were not substantially reduced. After cooling in water, the numbers of coliforms and E. coli were about 1 log unit less and the numbers of presumptive staphylococci plus listerias were about 0.5 log unit less than the numbers on dressed carcasses, but the numbers of aerobes were not reduced. The numbers of aerobes were 1 log unit more on boneless breasts, and 0.5 log units more on skin-on thighs and breasts that had been tumbled with brine than on cooled carcasses; and presumptive staphylococci plus listerias were 0.5 log unit more on thighs than on cooled carcasses. Otherwise the numbers of bacteria on the product were not substantially affected by processing. Listerias were <20% of the presumptive staphylococci plus listerias group of organisms recovered from product at each point in the process except after breasts were tumbled with brine, when >40% of the organisms were listerias.
A novel TRPM8 agonist relieves dry eye discomfort.
Yang, Jee Myung; Li, Fengxian; Liu, Qin; Rüedi, Marco; Wei, Edward Tak; Lentsman, Michael; Lee, Hyo Seok; Choi, Won; Kim, Seong Jin; Yoon, Kyung Chul
2017-06-26
Physical cooling of the eye surface relieves ocular discomfort, but translating this event to drug treatment of dry eye discomfort not been studied. Here, we synthesized a water-soluble TRPM8 receptor agonist called cryosim-3 (C3, 1-diisopropylphosphorylnonane) which selectively activates TRPM8 (linked to cooling) but not TRPV1 or TRPA1 (linked to nociception) and tested C3 in subjects with mild forms of dry eye disease. A set of 1-dialkylphosphoryalkanes were tested for activation of TRPM8, TRPV1 and TRPA1 receptors in transfected cells. The bioactivity profiles were compared by perioral, topical, and intravenous delivery to anesthetized rats. The selected lead candidate C3 or vehicle (water) was applied with a cotton gauze pad to upper eyelids of patients with dry eye disease (n = 30). Cooling sensation, tear film break-up time (TBUT), basal tear secretion, and corneal staining were evaluated. C3 was then applied four times daily for 2 weeks to patients using a pre-loaded single unit applicator containing 2 mg/mL of C3 in water (n = 20) or water only. TBUT, basal tear secretion, and corneal staining, and three questionnaires surveys of ocular discomfort (VAS scale, OSDI, and CVS symptoms) were analyzed before and at 1 and 2 weeks thereafter. C3 was a selective and potent TRPM8 agonist without TRPV1 or TRPA1 activity. In test animals, the absence of shaking behavior after C3 perioral administration made it the first choice for further study. C3 increased tear secretion in an animal model of dry eye disease and did not irritate when wiped on eyes of volunteers. C3 singly applied (2 mg/ml) produced significant cooling in <5 min, an effecting lasting 46 min with an increase in tear secretion for 60 min. C3 applied for 2 weeks also significantly increased basal tear secretion with questionnaire surveys of ocular discomfort indices clearly showing improvement of symptoms at 1 and 2 weeks. No complaints of irritation or pain were reported by any subject. C3 is a promising candidate for study of TRPM8 function on the eye surface and for relief of dry eye discomfort. ISRCTN24802609 and ISRCTN13359367 . Registered 23 March 2015 and 2 September 2015.
Nano Peltier cooling device from geometric effects using a single graphene nanoribbon
NASA Astrophysics Data System (ADS)
Li, Wan-Ju; Yao, Dao-Xin; Carlson, Erica
2012-02-01
Based on the phenomenon of curvature-induced doping in graphene we propose a class of Peltier cooling devices, produced by geometrical effects, without gating. We show how a graphene nanoribbon laid on an array of curved nano cylinders can be used to create a targeted cooling device. Using theoretical calculations and experimental inputs, we predict that the cooling power of such a device can approach 1kW/cm^2, on par with the best known techniques using standard lithography methods. The structure proposed here helps pave the way toward designing graphene electronics which use geometry rather than gating to control devices.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Romanenko, A., E-mail: aroman@fnal.gov; Grassellino, A., E-mail: annag@fnal.gov; Melnychuk, O.
We report a strong effect of the cooling dynamics through T{sub c} on the amount of trapped external magnetic flux in superconducting niobium cavities. The effect is similar for fine grain and single crystal niobium and all surface treatments including electropolishing with and without 120 °C baking and nitrogen doping. Direct magnetic field measurements on the cavity walls show that the effect stems from changes in the flux trapping efficiency: slow cooling leads to almost complete flux trapping and higher residual resistance, while fast cooling leads to the much more efficient flux expulsion and lower residual resistance.
Preliminary design of the cryogenic cooled limb scanning interferometer radiometer (CLIR)
NASA Technical Reports Server (NTRS)
Sherman, A.
1978-01-01
The preliminary design of the cryogenic cooling system for the Cryogenic Cooled Limb Scanning Interferometer Radiometer (CLIR) instrument to be flown on the Atmospheric Magnetospheric Physics Satellite (AMPS) was studied. The top level trade studies were extensive due to the instrument requirement for cooling at three temperature levels as opposed to the two levels initially described for the instrument. Approximately 12 different combinations of cryogens were investigated. The basic lifetime requirement for the instrument was 30 days. However, studies were also conducted for a follow-up mission requiring a 1 year lifetime. The top level trades led to the selection of a single stage supercritical helium baseline.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ross, Kyle W.; Gauntt, Randall O.; Cardoni, Jeffrey N.
2013-11-01
Data, a brief description of key boundary conditions, and results of Sandia National Laboratories’ ongoing MELCOR analysis of the Fukushima Unit 2 accident are given for the reactor core isolation cooling (RCIC) system. Important assumptions and related boundary conditions in the current analysis additional to or different than what was assumed/imposed in the work of SAND2012-6173 are identified. This work is for the U.S. Department of Energy’s Nuclear Energy University Programs fiscal year 2014 Reactor Safety Technologies Research and Development Program RC-7: RCIC Performance under Severe Accident Conditions.
Industrial and biomedical use of aerospace personal cooling garments
NASA Technical Reports Server (NTRS)
Williams, B. A.; Mcewen, G. N., Jr.; Montgomery, L. D.; Elkins, W. E.
1975-01-01
Liquid-cooled garments (LCG) have been developed which utilize liquid-cooled modules rather than the network of tygon tubing typical of Apollo LCG's. The ultra-thin, heat-sealed, polyurethane modules are situated over the body to cover 50 percent of the body surface area with special emphasis on the 'working' muscles and the head-neck area. These garments are being designed specifically for industrial and biomedical uses, such as: a head-neck cooling system which is being tested for race-car drivers, tractor drivers, truck drivers, or a head-neck cooling system tested for the reduction of the scalp hair loss which normally accompanies cancer treatments. A combined head-neck and thorax unit is being developed for use during mine distaster rescue operations, and for other hazardous hot applications. Finally applications for head-neck and partitional cooling are anticipated for military pilots, tank drivers, and heavy equipment operations.
Heat-Pipe-Cooled Leading Edges for Hypersonic Vehicles
NASA Technical Reports Server (NTRS)
Glass, David E.
2006-01-01
Heat pipes can be used to effectively cool wing leading edges of hypersonic vehicles. . Heat-pipe leading edge development. Design validation heat pipe testing confirmed design. Three heat pipes embedded and tested in C/C. Single J-tube heat pipe fabricated and testing initiated. HPCLE work is currently underway at several locations.
Optimization of Turbine Rim Seals
NASA Technical Reports Server (NTRS)
Wagner, J. H.; Tew, D. E.; Stetson, G. M.; Sabnis, J. S.
2006-01-01
Experiments are being conducted to gain an understanding of the physics of rim scale cavity ingestion in a turbine stage with the high-work, single-stage characteristics envisioned for Advanced Subsonic Transport (AST) aircraft gas turbine engines fo the early 21st century. Initial experimental measurements to be presented include time-averaged turbine rim cavity and main gas path static pressure measurements for rim seal coolant to main gas path mass flow ratios between 0 and 0.02. The ultimate objective of this work is develop improved rim seal design concepts for use in modern high-work, single sage turbines n order to minimize the use of secondary coolant flow. Toward this objective the time averaged and unsteady data to be obtained in these experiments will be used to 1) Quantify the impact of the rim cavity cooling air on the ingestion process. 2) Quantify the film cooling benefits of the rim cavity purge flow in the main gas path. 3) Quantify the impact of the cooling air on turbine efficiency. 4) Develop/evaluate both 3D CFD and analytical models of the ingestion/cooling process.
Forced Two-Phase Helium Cooling Scheme for the Mu2e Transport Solenoid
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tatkowski, G.; Cheban, S.; Dhanaraj, N.
2015-01-01
The Mu2e Transport Solenoid (TS) is an S-shaped magnet formed by two separate but similar magnets, TS-u and TS-d. Each magnet is quarter-toroid shaped with a centerline radius of approximately 3 m utilizing a helium cooling loop consisting of 25 to 27 horizontal-axis rings connected in series. This cooling loop configuration has been deemed adequate for cooling via forced single phase liquid helium; however it presents major challenges to forced two-phase flow such as “garden hose” pressure drop, concerns of flow separation from tube walls, difficulty of calculation, etc. Even with these disadvantages, forced two-phase flow has certain inherent advantagesmore » which make it a more attractive option than forced single phase flow. It is for this reason that the use of forced two-phase flow was studied for the TS magnets. This paper will describe the analysis using helium-specific pressure drop correlations, conservative engineering approach, helium properties calculated and updated at over fifty points, and how the results compared with those in literature. Based on the findings, the use of forced-two phase helium is determined to be feasible for steady-state cooling of the TS solenoids« less
Shape-optimization of round-to-slot holes for improving film cooling effectiveness on a flat surface
NASA Astrophysics Data System (ADS)
Huang, Ying; Zhang, Jing-zhou; Wang, Chun-hua
2018-01-01
Single-objective optimization for improving adiabatic film cooling effectiveness is performed for single row of round-to-slot film cooling holes on a flat surface by using CFD analysis and surrogate approximation methods. Among the main geometric parameters, dimensionless hole-to-hole pitch (P/d) and slot length-to-diameter (l/d) are fixed as 2.4 and 2 respectively, and the other parameters (hole height-to-diameter ratio, slot width-to-diameter and inclination angle) are chosen as the design variables. Given a wide range of possible geometric variables, the geometric optimization of round-to-slot holes is carried out under two typical blowing ratios of M = 0.5 and M = 1.5 by selecting a spatially-averaged adiabatic film cooling effectiveness between x/d = 2 and x/d = 12 as the objective function to be maximized. Radial basis function neural network is applied for constructing the surrogate model and then the optimal design point is searched by a genetic algorithm. It is revealed that the optimal round-to-slot hole is of converging feature under a low blowing ratio but of diffusing feature under a high blowing ratio. Further, the influence principle of optimal round-to-slot geometry on film cooling performance is illustrated according to the detailed flow and thermal behaviors.
Shape-optimization of round-to-slot holes for improving film cooling effectiveness on a flat surface
NASA Astrophysics Data System (ADS)
Huang, Ying; Zhang, Jing-zhou; Wang, Chun-hua
2018-06-01
Single-objective optimization for improving adiabatic film cooling effectiveness is performed for single row of round-to-slot film cooling holes on a flat surface by using CFD analysis and surrogate approximation methods. Among the main geometric parameters, dimensionless hole-to-hole pitch ( P/ d) and slot length-to-diameter ( l/ d) are fixed as 2.4 and 2 respectively, and the other parameters (hole height-to-diameter ratio, slot width-to-diameter and inclination angle) are chosen as the design variables. Given a wide range of possible geometric variables, the geometric optimization of round-to-slot holes is carried out under two typical blowing ratios of M = 0.5 and M = 1.5 by selecting a spatially-averaged adiabatic film cooling effectiveness between x/ d = 2 and x/ d = 12 as the objective function to be maximized. Radial basis function neural network is applied for constructing the surrogate model and then the optimal design point is searched by a genetic algorithm. It is revealed that the optimal round-to-slot hole is of converging feature under a low blowing ratio but of diffusing feature under a high blowing ratio. Further, the influence principle of optimal round-to-slot geometry on film cooling performance is illustrated according to the detailed flow and thermal behaviors.
NASA Technical Reports Server (NTRS)
Kinney, George R; Abramson, Andrew E; Sloop, John L
1952-01-01
Report presents the results of an investigation conducted to determine the effectiveness of liquid-cooling films on the inner surfaces of tubes containing flowing hot air. Experiments were made in 2- and 4-inch-diameter straight metal tubes with air flows at temperatures from 600 degrees to 2000 degrees F. and diameter Reynolds numbers from 2.2 to 14 x 10(5). The film coolant, water, was injected around the circumference at a single axial position on the tubes at flow rates from 0.02 to .24 pound per second per foot of tube circumference (0.8 to 12 percent of the air flow). Liquid-coolant films were established and maintained around and along the tube wall in concurrent flow with the hot air. The results indicated that, in order to film cool a given surface area with as little coolant flow as possible, it may be necessary to limit the flow of coolant introduced at a single axial position and to introduce it at several axial positions. The flow rate of inert coolant required to maintain liquid-film cooling over a given area of tube surface can be estimated when the gas-flow conditions are known by means of a generalized plot of the film-cooling data.
Provision of servo-controlled cooling during neonatal transport.
Johnston, Ewen D; Becher, Julie-Clare; Mitchell, Anne P; Stenson, Benjamin J
2012-09-01
Therapeutic hypothermia is a time critical intervention for infants who have experienced a hypoxic-ischaemic event. Previously reported methods of cooling during transport do not demonstrate the same stability achieved in the neonatal unit. The authors developed a system which allowed provision of servo-controlled cooling throughout transport, and present their first year's experience. Retrospective review of routinely collected patient data. 14 out-born infants were referred for cooling during a 12-month period. Nine infants were managed with the servo-controlled system during transport. Cooling was commenced in all infants before 6 h of life. Median time from team arrival to the infant having a temperature in the target range (33-34°C) was 45 min. Median temperature during transfer was 33.5°C (range 33-34°C). Temperature on arrival at the cooling centre ranged from 33.4°C to 33.8°C. Servo-controlled cooling during transport is feasible and provides an optimal level of thermal control.
NASA Astrophysics Data System (ADS)
Delucia, M.; Bronconi, R.; Carnevale, E.
1994-04-01
Gas turbine air cooling systems serve to raise performance to peak power levels during the hot months when high atmospheric temperatures cause reductions in net power output. This work describes the technical and economic advantages of providing a compressor inlet air cooling system to increase the gas turbine's power rating and reduce its heat rate. The pros and cons of state-of-the-art cooling technologies, i.e., absorption and compression refrigeration, with and without thermal energy storage, were examined in order to select the most suitable cooling solution. Heavy-duty gas turbine cogeneration systems with and without absorption units were modeled, as well as various industrial sectors, i.e., paper and pulp, pharmaceuticals, food processing, textiles, tanning, and building materials. The ambient temperature variations were modeled so the effects of climate could be accounted for in the simulation. The results validated the advantages of gas turbine cogeneration with absorption air cooling as compared to other systems without air cooling.
Gromme, S.; Deino, A.M.; Best, M.G.; Hudson, M.R.
1997-01-01
Outflow sheets of the Hiko tuff and the Racer Canyon tuff, which together extend over approximately 16000 km2 around the Caliente caldera complex in southeastern Nevada, have long been considered to be products of simultaneous or near-simultaneous eruptions from inset calderas in the west and east ends, respectively, of the caldera complex. New high-precision 40Ar/39Ar geochronology and paleomagnetic data demonstrate that emplacement of the uppermost part of the Racer Canyon tuff at 18.33??0.03 Ma was nearly synchronous with emplacement of the single outflow cooling unit of the much larger overlying Hiko tuff at 18.32??0.04 Ma. Based on comparison with the geomagnetic polarity time scale derived from the sea-floor spreading record, we conclude that emplacement of the first of several outflow cooling units of the Racer Canyon tuff commenced approximately 0.5 m.y. earlier. Only one paleomagnetic polarity is found in the Hiko tuff, but at least two paleomagnetic reversals have been found in the Racer Canyon tuff. The two formations overlap in only one place, at and near Panaca Summit northeast of the center of the Caliente caldera complex; here the Hiko tuff is stratigraphically above the Racer Canyon tuff. This study demonstrates the power of combining 40Ar/39Ar and paleomagnetic data in conjunction with phenocryst compositional modes to resolve problematic stratigraphic correlations in complex ash-flow sequences where use of one method alone might not eliminate ambiguities.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jansen, S.D.
1981-09-01
The report was prepared as part of the Ohio River Basin Energy Study (ORBES), a multidisciplinary policy research program. The ORBES region consists of all of Kentucky, most of West Virginia, substantial parts of Illinois, Indiana, and Ohio, and southwestern Pennsylvania. The inventory lists installed electrical generating capacity in commercial service as of December 1, 1976, and scheduled capacity additions and removals between 1977 and 1986 in the six ORBES states (Illinois, Indiana, Kentucky, Ohio, Pennsylvania, and West Virginia). The following information is included for each electrical generating unit: unit ID code, company index, whether joint or industrial ownership, plantmore » name, whether inside or outside the ORBES region, FIPS county code, type of unit, size in megawatts, type of megawatt rating, status of unit, date of commercial operation (actual or scheduled), scheduled retirement date (if any), primary fuel, alternate fuel, type of cooling, source of cooling water, and source of information.« less
NASA Technical Reports Server (NTRS)
Ganguly, J.; Yang, H.; Ghose, S.
1993-01-01
The cooling rates of meteorites provide important constraints on the size of their parent bodies, and their accretionary and evolutionary histories. However, the cooling rates obtained so far from the commonly used metallographic, radiometric and fission-track methods have been sometimes quite controversial, such as in the case of the mesosiderites and the meteorite Shaw. We have undertaken a systematic study of the cooling rates of meteorites using a different approach, which involves single crystal x-ray determination of Fe(2+)-Mg ordering in orthopyroxenes (OP(x)) in meteorites, subject to bulk compositional constraints, and numerical simulation of the evolution of the ordering state as a function of cooling rate, within the framework of the thermodynamic and kinetic principles governing cation ordering. We report the results obtained for OP(x) crystals from Shaw and two mesosiderites, Estherville and Bondoc.
NASA Astrophysics Data System (ADS)
Xu, Ya; Sun, Daming; Qiao, Xin; Yu, Yan S. W.; Zhang, Ning; Zhang, Jie; Cai, Yachao
2017-04-01
High cooling capacity Stirling cryocooler generally has hundreds to thousands watts of cooling power at liquid nitrogen temperature. It is promising in boil-off gas (BOG) recondensation and high temperature superconducting (HTS) applications. A high cooling capacity Stirling cryocooler driven by a crank-rod mechanism was developed and studied systematically. The pressure and frequency characteristics of the cryocooler, the heat rejection from the ambient heat exchanger, and the cooling performance are studied under different charging pressure. Energy conversion and distribution in the cryocooler are analyzed theoretically. With an electric input power of 10.9 kW and a rotating speed of 1450 r/min of the motor, a cooling power of 700 W at 77 K and a relative Carnot efficiency of 18.2% of the cryocooler have been achieved in the present study, and the corresponding pressure ratio in the compression space reaches 2.46.
Effects of Cooling Conditions on Tensile and Charpy Impact Properties of API X80 Linepipe Steels
NASA Astrophysics Data System (ADS)
Han, Seung Youb; Shin, Sang Yong; Lee, Sunghak; Kim, Nack J.; Bae, Jin-Ho; Kim, Kisoo
2010-02-01
In this study, four API X80 linepipe steel specimens were fabricated by varying the cooling rate and finish cooling temperature, and their microstructures and crystallographic orientations were analyzed to investigate the effects of the cooling conditions on the tensile and Charpy impact properties. All the specimens consisted of acicular ferrite (AF), granular bainite (GB), and martensite-austenite (MA) constituents. The volume fraction of MA increased with an increasing cooling rate, and the volume fraction and size of MA tended to decrease with an increasing finish cooling temperature. According to the crystallographic orientation analysis data, the effective grain size and unit crack path decreased as fine ACs having a large amount of high-angle grain boundaries were homogeneously formed, thereby leading to the improvement in the Charpy impact properties. The specimen fabricated with the higher cooling rate and lower finish cooling temperature had the highest upper-shelf energy (USE) and the lowest energy transition temperature (ETT), because it contained a large amount of MA homogeneously distributed inside fine AFs, while its tensile properties remained excellent.
NASA Technical Reports Server (NTRS)
Wade, Richard A.; Stark, M. A.; Green, Richard F.; Durrell, Patrick R.
2009-01-01
The hot subdwarf (sd) stars in the Palomar Green (PG) catalog of ultraviolet excess (UVX) objects play a key role in investigations of the frequency and types of binary companions and the distribution of orbital periods. These are important for establishing whether and by which channels the sd stars arise from interactions in close binary systems. It has been suggested that the list of PG sd stars is biased by the exclusion of many stars in binaries, whose spectra show the Ca I1 K line in absorption. A total of 1125 objects that were photometrically selected as candidates were ultimately rejected from the final PG catalog using this K-line criterion. We study 88 of these 'PG-Rejects' (PGRs), to assess whether there are significant numbers of unrecognized sd stars in binaries among the PGR objects. The presence of a sd should cause a large UVX, compared with the cool K-line star. We assemble GALEX, Johnson V, and 2MASS photometry and compare the colors of these PGR objects with those of known sd stars, cool single stars, and hot+cool binaries. Sixteen PGRs were detected in both the far- and near-ultraviolet GALEX passbands. Eleven of these, plus the 72 cases with only an upper limit in the far-ultraviolet band, are interpreted as single cool stars, appropriately rejected by the PG spectroscopy. Of the remaining five stars, three are consistent with being sd stars paired with a cool main sequence companion, while two may be single stars or composite systems of another type. We discuss the implications of these findings for the 1125 PGR objects as a whole. An enlarged study is desirable to increase confidence in these first results and to identify individual sd+cool binaries or other composites for follow-up study. The GALEX AIS data have sufficient sensitivity to carry out this larger study.
Air Distribution Retrofit Strategies for Affordable Housing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dentz, Jordan; Conlin, Francis; Holloway, Parker
2014-03-01
In multifamily and attached buildings, traditional duct sealing methods are often impractical or costly and disruptive because of the difficulty in accessing leakage sites. In this project, two retrofit duct sealing techniques -- manually-applied sealants and injecting a spray sealant, were implemented in several low-rise multi-unit buildings. An analysis on the cost and performance of the two methods are presented. Each method was used in twenty housing units: approximately half of each group of units are single story and the remainder two-story. Results show that duct leakage to the outside was reduced by an average of 59% through the usemore » of manual methods, and by 90% in the units where the injected spray sealant was used. It was found that 73% of the leakage reduction in homes that were treated with injected spray sealant was attributable to the manual sealing done at boots, returns and the air handler. The cost of manually-applying sealant ranged from $275 to $511 per unit and for the injected spray sealant the cost was $700 per unit. Modeling suggests a simple payback of 2.2 years for manual sealing and 4.7 years for the injected spray sealant system. Utility bills were collected for one year before and after the retrofits. Utility bill analysis shows 14% and 16% energy savings using injected spray sealant system and hand sealing procedure respectively in heating season whereas in cooling season, energy savings using injected spray sealant system and hand sealing were both 16%.« less
On the morphological and chemical stability of vitamin C crystals
NASA Astrophysics Data System (ADS)
Halász, Susan; Bodor, Beáta
1993-03-01
Mass cooling crystallization of aqueous vitamin C solution was studied by applying different cooling rates, initial supersaturations and mixing intensity. The morphology of the products (size, habit and colour) well followed the changes of process parameters. Comparing a high purity (99.9%) standard with a yellow coloured heterodisperse product and a slowly grown single crystal, HPLC chromatography detected decreasing purity of the bigger single crystals, while X-ray and NMR analysis did not show any perceptible difference. It has been concluded that not the surface oxidation (chemical degredation), but rather the inclusions are the main sources of impurities within the crystals.
Fiber-coupled pillar array as a highly pure and stable single-photon source
NASA Astrophysics Data System (ADS)
Odashima, S.; Sasakura, H.; Nakajima, H.; Kumano, H.
2017-12-01
A highly pure and stable single-photon source is prepared that comprises a well-designed pillar array, in which each pillar contains only a few InAs quantum dots. A nano-pillar in this array is in direct contact with a fiber end surface and cooled in a liquid-He bath. Auto-correlation measurements show that this source provides an average g(2)(0) value of 0.0174 in the measured excitation-power range. This photon source and fiber coupling are quite rigid against external disturbances such as cooling-heating cycles and vibration, with long-term stability.
Testing Numerical Models of Cool Core Galaxy Cluster Formation with X-Ray Observations
NASA Astrophysics Data System (ADS)
Henning, Jason W.; Gantner, Brennan; Burns, Jack O.; Hallman, Eric J.
2009-12-01
Using archival Chandra and ROSAT data along with numerical simulations, we compare the properties of cool core and non-cool core galaxy clusters, paying particular attention to the region beyond the cluster cores. With the use of single and double β-models, we demonstrate a statistically significant difference in the slopes of observed cluster surface brightness profiles while the cluster cores remain indistinguishable between the two cluster types. Additionally, through the use of hardness ratio profiles, we find evidence suggesting cool core clusters are cooler beyond their cores than non-cool core clusters of comparable mass and temperature, both in observed and simulated clusters. The similarities between real and simulated clusters supports a model presented in earlier work by the authors describing differing merger histories between cool core and non-cool core clusters. Discrepancies between real and simulated clusters will inform upcoming numerical models and simulations as to new ways to incorporate feedback in these systems.
Secondary Heating Under Quenching Cooling of Aluminum Alloys
NASA Astrophysics Data System (ADS)
Tsukrov, S. L.; Ber, L. B.
2017-07-01
Variants of secondary heating of aluminum alloys are considered, i.e., under quenching of plates in a water tank or on a horizontal quenching unit with water jet cooling, under continuous quenching of strips, and under quenching of tubes in vertical furnaces. Recommendation are given for removal or substantial reduction of the intensity of secondary heating under industrial conditions.
Quantitative data analysis to determine best food cooling practices in U.S. restaurants.
Schaffner, Donald W; Brown, Laura Green; Ripley, Danny; Reimann, Dave; Koktavy, Nicole; Blade, Henry; Nicholas, David
2015-04-01
Data collected by the Centers for Disease Control and Prevention (CDC) show that improper cooling practices contributed to more than 500 foodborne illness outbreaks associated with restaurants or delis in the United States between 1998 and 2008. CDC's Environmental Health Specialists Network (EHS-Net) personnel collected data in approximately 50 randomly selected restaurants in nine EHS-Net sites in 2009 to 2010 and measured the temperatures of cooling food at the beginning and the end of the observation period. Those beginning and ending points were used to estimate cooling rates. The most common cooling method was refrigeration, used in 48% of cooling steps. Other cooling methods included ice baths (19%), room-temperature cooling (17%), ice-wand cooling (7%), and adding ice or frozen food to the cooling food as an ingredient (2%). Sixty-five percent of cooling observations had an estimated cooling rate that was compliant with the 2009 Food and Drug Administration Food Code guideline (cooling to 41 °F [5 °C] in 6 h). Large cuts of meat and stews had the slowest overall estimated cooling rate, approximately equal to that specified in the Food Code guideline. Pasta and noodles were the fastest cooling foods, with a cooling time of just over 2 h. Foods not being actively monitored by food workers were more than twice as likely to cool more slowly than recommended in the Food Code guideline. Food stored at a depth greater than 7.6 cm (3 in.) was twice as likely to cool more slowly than specified in the Food Code guideline. Unventilated cooling foods were almost twice as likely to cool more slowly than specified in the Food Code guideline. Our data suggest that several best cooling practices can contribute to a proper cooling process. Inspectors unable to assess the full cooling process should consider assessing specific cooling practices as an alternative. Future research could validate our estimation method and study the effect of specific practices on the full cooling process.
Bakker, A; Siegel, J A; Mendell, M J; Peccia, J
2018-05-30
We investigated bacterial and fungal concentrations on cooling coils of commercial AC units and quantified associations between microbial loads and AC unit or building operational parameters. A field campaign was conducted to sample 25 AC units in the humid, subtropical climate of Southern CT, USA and 15 AC units in the hot-summer Mediterranean climate of Sacramento, CA, USA. Median concentrations (with interquartile range) of bacteria and fungi on the cooling coils were 1.2 × 10 7 (5.1 × 10 6 -3.9 × 10 7 ) cells/m 2 and 7.6 × 10 5 (5.6 × 10 4 -4.4 × 10 6 ) spore equivalents (SE)/m 2 , respectively. Concentrations varied among units with median unit concentrations ranging three orders of magnitude for bacteria and seven orders of magnitude for fungi. Controlled comparisons and multivariable regressions indicate that dominant factors associated with AC coil loading include the nominal efficiency of upstream filters (P = .008 for bacteria and P < .001 for fungi) and coil moisture, which was reflected in fungal loading differences between top and bottom halves of the AC coils in Southern CT (P = .05) and the dew points of the two climates considered (P = .04). Environmental and building characteristics explained 42% (P < .001) of bacterial concentration variability and 66% (P < .001) of fungal concentration variability among samples. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Polar nephelometer for atmospheric particulate studies
NASA Technical Reports Server (NTRS)
Hansen, M. Z.; Evans, W. H.
1980-01-01
A polar nephelometer for use in studying atmospheric aerosols was developed. The nephelometer detects molecular scatter from air and measures scattering from very clean air using pure molecular scattering for calibration. A compact system using a folded light path with an air cooled argon laser for the light source was designed. A small, sensitive detector unit permits easy angular rotation for changing the scattering angle. A narrow detector field of view of + or - 1/4 degree of scattering along with a single wavelength of incident light is used to minimize uncertainties in the scattering theory. The system is automated for data acquisition of the scattering matrix elements over an angular range from 2 degrees to 178 degrees of scattering. Both laser output and detector sensitivity are monitored to normalize the measured light scattering.
Calibration of CryojetHT and Cobra Plus Cryosystems used in X-ray diffraction studies
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dudka, A. P., E-mail: dudka@crys.ras.ru; Verin, I. A.; Smirnova, E. S.
CryoJetHT (Oxford Instruments) and Cobra Plus (Oxford Cryosystems) cryosystems, which are used for sample cooling in X-ray diffraction experiments, have been calibrated. It is shown that the real temperature in the vicinity of the sample differs significantly (the deviation is as high as 8–10 K at low temperatures) from the temperature recorded by authorized sensors of these systems. The calibration results are confirmed by measurements of the unit-cell parameters of GdFe{sub 3}(BO{sub 3}){sub 4} single crystal in the temperature range of its phase transition. It is shown that, to determine the real temperature of a sample, one must perform anmore » independent calibration of cryosystems rather than rely on their ratings.« less
NASA Astrophysics Data System (ADS)
Arkadyev, B. A.
2015-10-01
Basic principles of cooling of high-temperature steam turbines and constructive solutions used for development of the world's first cooled steam turbine SKR-100 (R-100-300) are described. Principal differences between the thermodynamic properties of cooling medium in the steam and gas turbines and the preference of making flow passes of cooled cylinders of steam turbines as reactive are shown. Some of its operation results and their conclusions are given. This turbine with a power of 100 MW, initial steam parameters approximately 30 MPa and 650°C, and back pressure 3 MPa was made by a Kharkov turbine plant in 1961 and ran successfully at a Kashira GRES (state district power plant) up to 1979, when it was taken out of use in a still fully operating condition. For comparison, some data on construction features and operation results of the super-high pressure cylinder of steam turbines of American Philo 6 (made by General Electric Co.) and Eddystone 1 (made by Westinghouse Co.) power generating units, which are close to the SKR-100 turbine by design initial steam parameters and the implementation time, are given. The high operational reliability and effectiveness of the cooling system that was used in the super-high pressure cylinder of the SKR-100 turbine of the power-generating unit, which were demonstrated in operation, confirms rightfulness and expediency of principles and constructive solutions laid at its development. As process steam temperatures are increased, the realization of the proposed approach to cooling of multistage turbines makes it possible to limit for large turbine parts the application of new, more expensive high-temperature materials, which are required for making steam boilers, and, in some cases, to do completely away with their utilization.
Mathematical model and calculation of water-cooling efficiency in a film-filled cooling tower
NASA Astrophysics Data System (ADS)
Laptev, A. G.; Lapteva, E. A.
2016-10-01
Different approaches to simulation of momentum, mass, and energy transfer in packed beds are considered. The mathematical model of heat and mass transfer in a wetted packed bed for turbulent gas flow and laminar wave counter flow of the fluid film in sprinkler units of a water-cooling tower is presented. The packed bed is represented as the set of equivalent channels with correction to twisting. The idea put forward by P. Kapitsa on representation of waves on the interphase film surface as elements of the surface roughness in interaction with the gas flow is used. The temperature and moisture content profiles are found from the solution of differential equations of heat and mass transfer written for the equivalent channel with the volume heat and mass source. The equations for calculation of the average coefficients of heat emission and mass exchange in regular and irregular beds with different contact elements, as well as the expression for calculation of the average turbulent exchange coefficient are presented. The given formulas determine these coefficients for the known hydraulic resistance of the packed bed element. The results of solution of the system of equations are presented, and the water temperature profiles are shown for different sprinkler units in industrial water-cooling towers. The comparison with experimental data on thermal efficiency of the cooling tower is made; this allows one to determine the temperature of the cooled water at the output. The technical solutions on increasing the cooling tower performance by equalization of the air velocity profile at the input and creation of an additional phase contact region using irregular elements "Inzhekhim" are considered.
Refrigeration generation using expander-generator units
NASA Astrophysics Data System (ADS)
Klimenko, A. V.; Agababov, V. S.; Koryagin, A. V.; Baidakova, Yu. O.
2016-05-01
The problems of using the expander-generator unit (EGU) to generate refrigeration, along with electricity were considered. It is shown that, on the level of the temperatures of refrigeration flows using the EGU, one can provide the refrigeration supply of the different consumers: ventilation and air conditioning plants and industrial refrigerators and freezers. The analysis of influence of process parameters on the cooling power of the EGU, which depends on the parameters of the gas expansion process in the expander and temperatures of cooled environment, was carried out. The schematic diagram of refrigeration generation plant based on EGU is presented. The features and advantages of EGU to generate refrigeration compared with thermotransformer of steam compressive and absorption types were shown, namely: there is no need to use the energy generated by burning fuel to operate the EGU; beneficial use of the heat delivered to gas from the flow being cooled in equipment operating on gas; energy production along with refrigeration generation, which makes it possible to create, using EGU, the trigeneration plants without using the energy power equipment. It is shown that the level of the temperatures of refrigeration flows, which can be obtained by using the EGU on existing technological decompression stations of the transported gas, allows providing the refrigeration supply of various consumers. The information that the refrigeration capacity of an expander-generator unit not only depends on the parameters of the process of expansion of gas flowing in the expander (flow rate, temperatures and pressures at the inlet and outlet) but it is also determined by the temperature needed for a consumer and the initial temperature of the flow of the refrigeration-carrier being cooled. The conclusion was made that the expander-generator units can be used to create trigeneration plants both at major power plants and at small energy.
Economic feasibility of cooling dry cows across the United States.
Ferreira, F C; Gennari, R S; Dahl, G E; De Vries, A
2016-12-01
Heat stress during the dry period reduces milk yield in the subsequent lactation of dairy cows. Our objectives were to quantify the economic losses due to heat stress if dry cows are not cooled and to evaluate the economic feasibility of dry cow cooling. We used weather data from the National Oceanic and Atmospheric Administration to calculate the number of heat stress days for each of the 50 US states. A heat stress day was declared when the daily average temperature-humidity index was ≥68. The number of dairy cows in each state in 2015 was obtained from the USDA-National Agricultural Statistics Service. We assumed that 15% of the cows were dry at any time, a 60-d dry period, and a calving interval of 400d. Only cows in their second or greater parity (65%) benefitted from cooling during the dry period of the previous parity. Milk yield decreased by 5kg in the subsequent lactation (340d) if the cow experienced heat stress during the dry period based on a review of the literature. The default marginal value of milk minus feed cost was $0.33/kg of milk. The investment analysis included purchases of fans and soakers and use of water and electricity. Investment in a dry cow barn was considered separately. The average US dairy cow would experience 96 (26%) heat stress days during the year if not cooled and loses 447kg of milk in the subsequent lactation if not cooled when dry. Annual losses would be $810 million if dry cows were not cooled ($87/cow per yr). For the top 3 milk-producing states (California, Wisconsin, New York), and Florida and Texas, the average milk losses in the subsequent lactation were 522, 349, 387, 1,197, and 904kg, and reduced profit per cow per year would be $101, $68, $75, $233, and $176, respectively. The average benefit-cost ratio and payback periods of cooling dry cows in the United States were 3.15 and 0.27 yr (dry cow barn already present) and 1.45 and 5.68 yr (if investing in a dry cow barn) in the default scenario. To reach positive net present values, 6d (barn is present) and 55d (barn investment necessary) of heat stress annually were necessary (default assumptions). Other benefits of cooling, such as increased health and more productive offspring, were not considered. In conclusion, cooling of dry cows was profitable for 89% of the cows in the United States when building a new barn is required (under default assumptions) and very profitable when construction of a dry cow barn is not required (except for Alaska). Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
1983-01-01
Because quadriplegics are unable to perspire below the level of spinal injury, they cannot tolerate heat stress. A cooling vest developed by Ames Research Center and Upjohn Company allows them to participate in outdoor activities. The vest is an adaptation of Ames technology for thermal control garments used to remove excess body heat of astronauts. The vest consists of a series of corrugated channels through which cooled water circulates. Its two outer layers are urethane coated nylon, and there is an inner layer which incorporates the corrugated channels. It can be worn as a backpack or affixed to a wheelchair. The unit includes a rechargeable battery, mini-pump, two quart reservoir and heat sink to cool the water.
Subsystem design package for Mod 2 site data acquisition system: Solar heating and cooling
NASA Technical Reports Server (NTRS)
1977-01-01
The Mod II Site Data Acquisition Subsystem (SDAS) is designed to collect data from sensors located on residential or commercial buildings using a solar heating and/or cooling system. The SDAS takes the data obtained from sensors located on the solar heating and/or cooling system, processes the data into a suitable format, stores the data for a period of time, and provides the capability for both telephone retrieval by the Central Data Processing System (CDPS) and manual retrieval of the data for transfer to the central site. The unit is designed so it will not degrade the operation of the solar heating/cooling system which it is monitoring.
Laser Cooling the Diatomic Molecule CaH
NASA Astrophysics Data System (ADS)
Velasquez, Joe, III; Di Rosa, Michael
2014-06-01
To laser-cool a species, a closed (or nearly closed) cycle is required to dissipate translational energy through many directed laser-photon absorption and subsequent randomly-directed spontaneous emission events. Many atoms lend themselves to such a closed-loop cooling cycle. Attaining laser-cooled molecular species is challenging because of their inherently complex internal structure, yet laser-cooling molecules could lead to studies in interesting chemical dynamics among other applications. Typically, laser-cooled atoms are assembled into molecules through photoassociation or Feschbach resonance. CaH is one of a few molecules whose internal structure is quite atom-like, allowing a nearly closed cycle without the need for many repumping lasers. We will also present our work-to-date on laser cooling this molecule. We employ traditional pulsed atomic/molecular beam techniques with a laser vaporization source to generate species with well-defined translational energies over a narrow range of velocity. In this way, we can apply laser-cooling to most species in the beam along a single dimension (the beam's axis). This project is funded by the LDRD program of the Los Alamos National Laboratory.
Optoelectrical Cooling of Formaldehyde to Sub-Millikelvin Temperatures
NASA Astrophysics Data System (ADS)
Zeppenfeld, Martin
2016-05-01
Due to their strong long-range dipole-dipole interactions and large number of internal states, polar molecules cooled to ultracold temperatures enable fascinating applications ranging from ultracold chemistry to investigation of dipolar quantum gases. However, realizing a simple and general technique to cool molecules to ultracold temperatures, akin to laser cooling of atoms, has been a formidable challenge. We present results for opto-electrical Sisyphus cooling applied to formaldehyde (H2 CO). In this generally applicable cooling scheme, molecules repeatedly move up and down electric field gradients of a trapping potential in different rotational states to efficiently extract kinetic energy. A total of about 300,000 molecules are thereby cooled by a factor of 1000 to 400uK, resulting in a record-large ensemble of ultracold molecules. In addition to cooling of the motional degrees of freedom, optical pumping via a vibrational transition allows us to control the internal rotational state. We thereby achieve a purity of over 80% of formaldehyde molecules in a single rotational M-sublevel. Our experiment provides an excellent starting point for precision spectroscopy and investigation of ultracold collisions.
NASA Technical Reports Server (NTRS)
Camarda, Charles J.; Riley, Michael F.
1987-01-01
Nonlinear mathematical programming methods are used to design a radiantly cooled and heat-pipe-cooled panel for a Mach 6.7 transport. The cooled portion of the panel is a hybrid heat-pipe/actively cooled design which uses heat pipes to transport the absorbed heat to the ends of the panel where it is removed by active cooling. The panels are optimized for minimum mass and to satisfy a set of heat-pipe, structural, geometric, and minimum-gage constraints. Two panel concepts are investigated: cylindrical heat pipes embedded in a honeycomb core and an integrated design which uses a web-core heat-pipe sandwich concept. The latter was lighter and resulted in a design which was less than 10 percent heavier than an all actively cooled concept. The heat-pipe concept, however, is redundant and can sustain a single-point failure, whereas the actively cooled concept cannot. An additional study was performed to determine the optimum number of coolant manifolds per panel for a minimum-mass design.
NASA Astrophysics Data System (ADS)
Ritz, G.; Hirai, T.; Norajitra, P.; Reiser, J.; Giniyatulin, R.; Makhankov, A.; Mazul, I.; Pintsuk, G.; Linke, J.
2009-12-01
Tungsten was selected as armor material for the helium-cooled divertor in future DEMO-type fusion reactors and fusion power plants. After realizing the design and testing of them under cyclic thermal loads of up to ~14 MW m-2, the tungsten divertor plasma-facing units were examined by metallography; they revealed failures such as cracks at the thermal loaded and as-machined surfaces, as well as degradation of the brazing layers. Furthermore, in order to optimize the machining processes, the quality of tungsten surfaces prepared by turning, milling and using a diamond cutting wheel were examined. This paper presents a metallographic examination of the tungsten plasma-facing units as well as technical studies and the characterization on machining of tungsten and alternative brazing joints.
An unusual type of polymorphism in a liquid crystal
Li, Lin; Salamonczyk, Miroslaw; Shadpour, Sasan; ...
2018-02-19
Polymorphism is a remarkable concept in chemistry, materials science, computer science, and biology. Whether it is the ability of a material to exist in two or more crystal structures, a single interface connecting to two different entities, or alternative phenotypes of an organism, polymorphism determines function and properties. In materials science, polymorphism can be found in an impressively wide range of materials, including crystalline materials, minerals, metals, alloys, and polymers. Here in this paper we report on polymorphism in a liquid crystal. A bent-core liquid crystal with a single chiral side chain forms two structurally and morphologically significantly different liquidmore » crystal phases solely depending on the cooling rate from the isotropic liquid state. On slow cooling, the thermodynamically more stable oblique columnar phase forms, and on rapid cooling, a not heretofore reported helical microfilament phase. Since structure determines function and properties, the structural color for these phases also differs.« less
High efficiency 40 K single-stage Stirling-type pulse tube cryocooler
NASA Astrophysics Data System (ADS)
Wu, X. L.; Chen, L. B.; Pan, C. Z.; Cui, C.; Wang, J. J.; Zhou, Y.
2017-12-01
A high efficiency single-stage Stirling-type coaxial pulse tube cryocooler (SPTC) operating at around 40 K has been designed, built and tested. The double-inlet and the inertance tubes together with the gas reservoir were adopted as the phase shifters. Under the conditions of 2.5 MPa charging pressure and 30 Hz operating frequency, the prototype has achieved a no-load temperature of 23.8 K with 330 W of electric input power at a rejection temperature of 279 K. When the input power increases to 400 W, it can achieve a cooling capacity of 4.7 W/40 K while rejecting heat at 279 K yielding an efficiency of 7.02% relative to Carnot. It achieves a cooling capacity of 5 W/40 K with an input power of 450 W. It takes 10 minutes for the SPTC to cool to its no-load temperature of 40 K from 295 K.
An unusual type of polymorphism in a liquid crystal
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Lin; Salamonczyk, Miroslaw; Shadpour, Sasan
Polymorphism is a remarkable concept in chemistry, materials science, computer science, and biology. Whether it is the ability of a material to exist in two or more crystal structures, a single interface connecting to two different entities, or alternative phenotypes of an organism, polymorphism determines function and properties. In materials science, polymorphism can be found in an impressively wide range of materials, including crystalline materials, minerals, metals, alloys, and polymers. Here in this paper we report on polymorphism in a liquid crystal. A bent-core liquid crystal with a single chiral side chain forms two structurally and morphologically significantly different liquidmore » crystal phases solely depending on the cooling rate from the isotropic liquid state. On slow cooling, the thermodynamically more stable oblique columnar phase forms, and on rapid cooling, a not heretofore reported helical microfilament phase. Since structure determines function and properties, the structural color for these phases also differs.« less
Analysis of advanced conceptual designs for single-family-size absorption chillers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Macriss, R.A.; Zawacki, T.S.; Kouo, M.T.
1978-01-01
The objective of this research study is the development of radically new fluid systems, specifically tailored to the needs and requirements of solar-absorption cooling for single-family-size residences. Progress is reported.
Effect of local cooling on sweating rate and cold sensation
NASA Technical Reports Server (NTRS)
Crawshaw, L. I.; Nadel, E. R.; Stolwijk, J. A. J.; Stamford, B. A.
1975-01-01
Subjects resting in a 39 C environment were stimulated in different skin regions with a water-cooled thermode. Results indicate that cooling different body regions produces generally equivalent decreases in sweating rate and increases in cold sensation, with the forehead showing a much greater sensitivity per unit area and temperature decrease than other areas. The high thermal sensitivity of the face may have evolved when it was the thinnest-furred area of the body; today's clothing habits have reestablished the importance of the face in the regulation of body temperature.
Modeling of Thermal Behavior of Raw Natural Gas Air Coolers
NASA Astrophysics Data System (ADS)
Scherbinin, S. V.; Prakhova, M. Yu; Krasnov, A. N.; Khoroshavina, E. A.
2018-05-01
When gas is being prepared for a long-range transportation, it passes through air cooling units (ACUs) after compressing; there, hot gas passing through finned tubes is cooled with air streams. ACU's mode of operation shall ensure a certain value of gas temperature at the ACU's outlet. At that, when cooling raw gas, temperature distribution along all the tubes shall be known to prevent local hydrate formation. The paper proposes a mathematical model allowing one to obtain a thermal field distribution inside the ACU and study influence of various factors onto it.
Congruent melting of gallium nitride at 6 GPa and its application to single-crystal growth.
Utsumi, Wataru; Saitoh, Hiroyuki; Kaneko, Hiroshi; Watanuki, Tetsu; Aoki, Katsutoshi; Shimomura, Osamu
2003-11-01
The synthesis of large single crystals of GaN (gallium nitride) is a matter of great importance in optoelectronic devices for blue-light-emitting diodes and lasers. Although high-quality bulk single crystals of GaN suitable for substrates are desired, the standard method of cooling its stoichiometric melt has been unsuccessful for GaN because it decomposes into Ga and N(2) at high temperatures before its melting point. Here we report that applying high pressure completely prevents the decomposition and allows the stoichiometric melting of GaN. At pressures above 6.0 GPa, congruent melting of GaN occurred at about 2,220 degrees C, and decreasing the temperature allowed the GaN melt to crystallize to the original structure, which was confirmed by in situ X-ray diffraction. Single crystals of GaN were formed by cooling the melt slowly under high pressures and were recovered at ambient conditions.
NASA Astrophysics Data System (ADS)
Betrie, G.; Yan, E.; Clark, C.
2016-12-01
Thermoelectric power plants use the highest amount of freshwater second to the agriculture sector. However, there is scarcity of information that characterizes the freshwater use of these plants in the United States. This could be attributed to the lack of model and data that are required to conduct analysis and gain insights. The competition for freshwater among sectors will increase in the future as the amount of freshwater gets limited due climate change and population growth. A model that makes use of less data is urgently needed to conduct analysis and identify adaptation strategies. The objectives of this study are to develop a model and simulate the water use of thermoelectric power plants in the United States. The developed model has heat-balance, climate, cooling system, and optimization modules. It computes the amount of heat rejected to the environment, estimates the quantity of heat exchanged through latent and sensible heat to the environment, and computes the amount of water required per unit generation of electricity. To verify the model, we simulated a total of 876 fossil-fired, nuclear and gas-turbine power plants with different cooling systems (CS) using 2010-2014 data obtained from Energy Information Administration. The CS includes once-through with cooling pond, once-through without cooling ponds, recirculating with induced draft and recirculating with induced draft natural draft. The results show that the model reproduced the observed water use per unit generation of electricity for the most of the power plants. It is also noticed that the model slightly overestimates the water use during the summer period when the input water temperatures are higher. We are investigating the possible reasons for the overestimation and address it in the future work. The model could be used individually or coupled to regional models to analyze various adaptation strategies and improve the water use efficiency of thermoelectric power plants.
Pollution control of industrial wastewater from soap and oil industries: a case study.
Abdel-Gawad, S; Abdel-Shafy, M
2002-01-01
Industrial wastewater from soap and oil industries represents a heavy pollution source on their receiving water body. This paper studies a case of pollution control at Tanta Soap and Oil Company, Banha Factory, Egypt. The factory production includes soap, edible oil, and animal fodder. About 4,347 m3/day of industrial wastewater effluent was discharged via gravity sewers to the public sewerage system. Most of the effluent was cooling water because the cooling process in the factory was open circle. In spite of the huge quantity of cooling water being disposed of, disposal of wastewater was violating pertinent legislation. Three procedures were used for controlling the pollution at the Banha Factory. Firstly, all open circuit cooling systems were converted to closed circuit thus reducing the quantity of the discharged wastewater down to 767 m3/day. Secondly, the heavily polluted oil and grease (O&G) wastewater from the refinery unit is treated via two gravity oil separator (GOS) units, dissolved air floatation (DAF), and biological units in order to reduce the high levels of O&G, BOD, COD, and SS to the allowable limits. Thirdly, the heavily polluted waste effluent from the 'red water' saponification unit is treated separately by acidification to convert the emulsified fatty acid to free form in order to be separated through an oil separation unit. The effluent is then passed to liming stage to neutralize excess acidity and precipitate some of the dissolved matters. The mixture is finally clarified and the pH is adjusted to the allowable limits. The effluent wastewater from the three processes is collected and mixed in a final equalization tank for discharging effluent to the public sewerage system. The characteristics of the effluent water are very good with respect to the allowable Egyptian limits for discharging effluent to the public sewerage system.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dallmeyer, R.D.; Gee, D.G.; Beckholmen, M.
In central portions of the Scandinavian Caledonides, greenschist facies volcanosedimentary successions within the Koeli Nappe Complex have been thrust several hundred kilometers eastward onto the Baltoscandian platform. These were derived from eugeoclinal terranes situated outboard (west) of the Baltica continent during the early Paleozoic. The Koeli Nappe Complex is tectonically underlain by higher grade units within the Seve Nappe Complex. These are composed of amphibolite and granulite facies rocks and locally contain eclogites. The Seve Nappes tectonically separate Koeli units from structurally lower allochthons derived from more inboard environments along the Baltoscandian miogeocline. Previous mineral isotopic age-determinations from Seve andmore » Koeli units have been in the 430 to 390 Ma range and have been interpreted to presumably date cooling following Scandian (Middle Silurian to Early Devonian) metamorphism. However, incremental-release /sup 40/Ar//sup 39/Ar dates recorded by minerals within some of the Koeli and Seve Nappes exposed in Jaemtland, Sweden (Taennforsen and Are districts) provide evidence of earlier tectonothermal activity. Hornblendes from the Seve and Koeli Nappe Complexes display variably discordant age spectra as a result of low-temperature, experimental evolution of loosely bound extraneous argon components. However, in most analyses plateau ages of 510 to 475 Ma (Koeli) and 465 to 455 Ma (Seve) are defined. In contrast, muscovite and biotite from all tectonic units record Scandian cooling ages between 245 and 410 Ma. The older events recorded by hornblende within these Seve and Koeli units are evidence of early Caledonian tectonothermal activity and subsequent diachronous cooling during the Early-Middle Ordovician.« less
Petrographic Evidence for Rapid Heating and Cooling During Chrondrule Formation
NASA Technical Reports Server (NTRS)
Wasson, J. T.
2004-01-01
The chondrule cooling rates used in most chondrule-formation models appear to be too low. Recent petrographic evidence indicates that the amount of crystal (especially olivine) growth that occurred after the last melting event was about 30 smaller than the grain sizes simulated in order to estimate cooling rates. The smaller amount of growth leads to an upwards revision of cooling rates by about a factor of 1000. Most chondrules are porphyritic. They consist of large and small crystals of olivine and, less commonly, pyroxene immersed in a mesostasis having a plagioclase-rich composition. In the most primitive chondrites the mesostasis is often vitreous. Because the large majority of chondrules contain FeS, it is clear that the nebula had cooled below the FeS condensation temperature (ca. 650 K) before chondrule formation occurred. The high FeO/(FeO+MgO) ratios of some chondrules require still lower nebular temperatures (less than 500 K). The traditional view has been that porphyritic chondrules formed in a single heating/cooling event and many laboratory experiments have been carried out in various kinds of kinds of furnaces to try to simulate the formation of chondrules textures in a single heating/cooling cycle. These furnace experiments have been used to infer the cooling rates of chondrules during the temperature range at which olivine crystallized from the melt. Most of these inferred values are in the range 0.01-1 K per second. These low cooling rates are problematical because there is no long-term nebular environment that yields such values. In transparent regions chondrules would cool at rates orders of magnitude higher, whereas in an opaque nebular disk the cooling rates would be many orders of magnitude lower. And these latter conditions are not suitable locations for chondrule formation because such high temperatures would cause the complete evaporation of chondrules (which have melting temperatures about 600 K higher than their evaporation temperatures). During the last several years several kinds of petrographic evidence indicating rapid chondrule cooling have been recognized. These include thin overgrowths on relict grains, clusters of small crystals that grew following the most recent melting event, and fragments preserving shardlike shapes that would have been hidden had several tens of micrometers of new growth occurred following the last melting event. And there are other indications of rapid cooling including the preservation of volatiles such as FeS and one case where the modeling of O-isotopic and FeO/(FeO+MgO) gradients indicated a high cooling rate.
NASA Astrophysics Data System (ADS)
Ma, Xiaoping; Li, Dianzhong
2018-07-01
The microstructures, segregation and cooling curve were investigated in the directional solidification of 20SiMnMo5 steel. The typical characteristic of faceted growth is identified. The microstructures within the single cellular and within the single dendritic arm, together with the contradictive segregation distribution against the cooling curve, verify the discrete crystal growth in multi-scales. Not only the single cellular/dendritic arm but also the single martensite zone within the single cellular/dendritic arm is produced by the discrete growth. In the viewpoint of segregation, the basic domain following continuous growth has not been revealed. Along with the multi-scale faceted discrete growth, the phase differentiation happens for both the solid and liquid. The differentiated liquid phases appear and evolve with different sizes, positions, compositions and durations. The physical mechanism for the faceted discrete growth is qualitatively established based on the nucleation of new faceted steps induced by the composition gradient and temperature gradient.
NASA Astrophysics Data System (ADS)
Ma, Xiaoping; Li, Dianzhong
2018-03-01
The microstructures, segregation and cooling curve were investigated in the directional solidification of 20SiMnMo5 steel. The typical characteristic of faceted growth is identified. The microstructures within the single cellular and within the single dendritic arm, together with the contradictive segregation distribution against the cooling curve, verify the discrete crystal growth in multi-scales. Not only the single cellular/dendritic arm but also the single martensite zone within the single cellular/dendritic arm is produced by the discrete growth. In the viewpoint of segregation, the basic domain following continuous growth has not been revealed. Along with the multi-scale faceted discrete growth, the phase differentiation happens for both the solid and liquid. The differentiated liquid phases appear and evolve with different sizes, positions, compositions and durations. The physical mechanism for the faceted discrete growth is qualitatively established based on the nucleation of new faceted steps induced by the composition gradient and temperature gradient.
Compact, single-tube scanning tunneling microscope with thermoelectric cooling.
Jobbins, Matthew M; Agostino, Christopher J; Michel, Jolai D; Gans, Ashley R; Kandel, S Alex
2013-10-01
We have designed and built a scanning tunneling microscope with a compact inertial-approach mechanism that fits inside the piezoelectric scanner tube. Rigid construction allows the microscope to be operated without the use of external vibration isolators or acoustic enclosures. Thermoelectric cooling and a water-ice bath are used to increase temperature stability when scanning under ambient conditions.
Solar heating and cooling system design and development
NASA Technical Reports Server (NTRS)
1979-01-01
The design and development of marketable solar heating and cooling systems for single family and commercial applications is described. The delivery, installation, and monitoring of the prototype systems are discussed. Seven operational test sites are discussed in terms of system performance. Problems encountered with equipment and installation were usually due to lack of skills required for solar system installation.
NASA Technical Reports Server (NTRS)
Guzik, Monica C.; Tomsik, Thomas M.
2011-01-01
As focus shifts towards long-duration space exploration missions, an increased interest in active thermal control of cryogenic propellants to achieve zero boil-off of cryogens has emerged. An active thermal control concept of considerable merit is the integration of a broad area cooling system for a cryogenic propellant tank with a combined cryocooler and circulator system that can be used to reduce or even eliminate liquid cryogen boil-off. One prospective cryocooler and circulator combination is the reverse turbo-Brayton cycle cryocooler. This system is unique in that it has the ability to both cool and circulate the coolant gas efficiently in the same loop as the broad area cooling lines, allowing for a single cooling gas loop, with the primary heat rejection occurring by way of a radiator and/or aftercooler. Currently few modeling tools exist that can size and characterize an integrated reverse turbo-Brayton cycle cryocooler in combination with a broad area cooling design. This paper addresses efforts to create such a tool to assist in gaining a broader understanding of these systems, and investigate their performance in potential space missions. The model uses conventional engineering and thermodynamic relationships to predict the preliminary design parameters, including input power requirements, pressure drops, flow rate, cycle performance, cooling lift, broad area cooler line sizing, and component operating temperatures and pressures given the cooling load operating temperature, heat rejection temperature, compressor inlet pressure, compressor rotational speed, and cryogenic tank geometry. In addition, the model allows for the preliminary design analysis of the broad area cooling tubing, to determine the effect of tube sizing on the reverse turbo-Brayton cycle system performance. At the time this paper was written, the model was verified to match existing theoretical documentation within a reasonable margin. While further experimental data is needed for full validation, this tool has already made significant steps towards giving a clearer understanding of the performance of a reverse turbo-Brayton cycle cryocooler integrated with broad area cooling technology for zero boil-off active thermal control.
Tunable nano Peltier cooling device from geometric effects using a single graphene nanoribbon
NASA Astrophysics Data System (ADS)
Li, Wan-Ju; Yao, Dao-Xin; Carlson, E. W.
2014-08-01
Based on the phenomenon of curvature-induced doping in graphene we propose a class of Peltier cooling devices, produced by geometrical effects, without gating. We show how a graphene nanoribbon laid on an array of curved nano cylinders can be used to create a targeted and tunable cooling device. Using two different approaches, the Nonequilibrium Green's Function (NEGF) method and experimental inputs, we predict that the cooling power of such a device can approach the order of kW/cm2, on par with the best known techniques using standard superlattice structures. The structure proposed here helps pave the way toward designing graphene electronics which use geometry rather than gating to control devices.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Romanenko, A.; Grassellino, A.; Melnychuk, O.
We report a strong effect of the cooling dynamics throughmore » $$T_\\mathrm{c}$$ on the amount of trapped external magnetic flux in superconducting niobium cavities. The effect is similar for fine grain and single crystal niobium and all surface treatments including electropolishing with and without 120$$^\\circ$$C baking and nitrogen doping. Direct magnetic field measurements on the cavity walls show that the effect stems from changes in the flux trapping efficiency: slow cooling leads to almost complete flux trapping and higher residual resistance while fast cooling leads to the much more efficient flux expulsion and lower residual resistance.« less
Influence of other rare earth ions on the optical refrigeration efficiency in Yb:YLF crystals.
Di Lieto, Alberto; Sottile, Alberto; Volpi, Azzurra; Zhang, Zhonghan; Seletskiy, Denis V; Tonelli, Mauro
2014-11-17
We investigated the effect of rare earth impurities on the cooling efficiency of Yb³⁺:LiYF₄ (Yb:YLF). The refrigeration performance of two single crystals, doped with 5%-at. Yb and with identical history but with different amount of contaminations, have been compared by measuring the cooling efficiency curves. Spectroscopic and elemental analyses of the samples have been carried out to identify the contaminants, to quantify their concentrations and to understand their effect on the cooling efficiencies. A model of energy transfer processes between Yb and other rare earth ions is suggested, identifying Erbium and Holmium as elements that produce a detrimental effect on the cooling performance.
Thirty Years of Near Room Temperature Magnetic Cooling: Where we are Today and Future Prospects
DOE Office of Scientific and Technical Information (OSTI.GOV)
K.A. Gschneidner, Jr; V.K. Pecharsky'
2008-05-01
The seminal study by Brown in 1976 showed that it was possible to use the magnetocaloric effect to produce a substantial cooling effect near room temperature. About 15 years later Green et al. built a device which actually cooled a load other than the magnetocaloric material itself and the heat exchange fluid. The major breakthrough, however, occurred in 1997 when the Ames Laboratory/Astronautics proof-of-principle refrigerator showed that magnetic refrigeration was competitive with conventional gas compression cooling. Since then, over 25 magnetic cooling units have been built and tested throughout the world. The current status of near room temperature magnetic coolingmore » is reviewed, including a discussion of the major problems facing commercialization and potential solutions thereof. The future outlook for this revolutionary technology is discussed.« less
NASA Astrophysics Data System (ADS)
Luo, Laihui; Dietze, Matthias; Solterbeck, Claus-Henning; Luo, Haosu; Es-Souni, Mohammed
2013-12-01
Single crystals based on solid solutions of lead-magnesium-niobate (PMN) and lead titanate (PT) have emerged as highly promising multifunctional systems combining piezoelectric, pyroelectric, and electro-optic properties that surpass by far those of the best known lead-zirkonium-titanate ceramics. In this paper we present new findings on how the phase transition temperature and the dielectric and ferroelectric properties can be tuned depending on crystal composition, orientation, and thermoelectrical treatment. Mn-doped and pure 0.72PbMg1/3Nb2/3O3-0.28PbTiO3 (0.72PMN-0.28PT) single crystals with ⟨111⟩ and ⟨001⟩ orientations were investigated. A special attention was devoted to field cooling (FC), i.e., cooling under electric field from different temperatures. The results illustrate different findings that were not reported before: the Curie temperature, i.e., ferroelectric-paraelectric transition temperature, is enhanced after field cooling of the Mn-doped, ⟨001⟩-oriented crystal while such a shift is not observed in the ⟨111⟩-oriented and the non-doped crystals. In addition, substantial polarization suppression occurs in the Mn-doped crystals upon FC from high temperature regardless of orientation. Based on piezoforce microscopy of the domain structure that shows suppression of domain growth following field cooling from 200 °C, we propose a mechanism for polarization suppression based on domain pinning by charged defects. The practical importance of our results lies in showing the opportunity offered by a proper choice of crystal composition and poling conditions for tuning the functional properties of PMN-PT single crystals for a specific application. This should contribute to the understanding of their properties towards advanced sensor and transducers devices.
Conditional cooling limit for a quantum channel going through an incoherent environment.
Straka, Ivo; Miková, Martina; Mičuda, Michal; Dušek, Miloslav; Ježek, Miroslav; Filip, Radim
2015-11-16
We propose and experimentally verify a cooling limit for a quantum channel going through an incoherent environment. The environment consists of a large number of independent non-interacting and non-interfering elementary quantum systems--qubits. The qubits travelling through the channel can only be randomly replaced by environmental qubits. We investigate a conditional cooling limit that exploits an additional probing output. The limit specifies when the single-qubit channel is quantum, i.e. it preserves entanglement. It is a fundamental condition for entanglement-based quantum technology.
Conditional cooling limit for a quantum channel going through an incoherent environment
Straka, Ivo; Miková, Martina; Mičuda, Michal; Dušek, Miloslav; Ježek, Miroslav; Filip, Radim
2015-01-01
We propose and experimentally verify a cooling limit for a quantum channel going through an incoherent environment. The environment consists of a large number of independent non-interacting and non-interfering elementary quantum systems – qubits. The qubits travelling through the channel can only be randomly replaced by environmental qubits. We investigate a conditional cooling limit that exploits an additional probing output. The limit specifies when the single-qubit channel is quantum, i.e. it preserves entanglement. It is a fundamental condition for entanglement-based quantum technology. PMID:26568362
NASA Astrophysics Data System (ADS)
Gulevsky, V. A.; Shatsky, V. P.; Osipov, E. I.; Menzhulova, A. S.
2018-03-01
For cooling the air environment of industrial premises water-evaporating air, conditioners are being increasingly applied. The simplicity of their construction, ecological safety and low power consumption distinguish them from the coolers of other types. Cooling the processed air is due to the loss of energy for the evaporation of moisture from the surface of the water-wetted plates that form air channels. As a result of this process, cooled air is often saturated with moisture, which limits the possibilities for the operation of the coolers of this type. In these cases, more complex coolers of indirect principle without such drawback should be applied. The most effective modification of indirect cooling is the installation of recuperative principle units. The paper presents a mathematical model of heat-mass transfer in such water-evaporating coolers. The scheme of realization of this model based on an iterative algorithm of solution of the system of finite–difference linear equations that takes into account longitudinal and transverse thermal conductivity of the heat transfer plates is suggested. The possibility of obtaining the optimal values of the redistribution of the main and auxiliary air flows through the substantiation of the aerodynamic resistance of the output grid is proved. This allows refusing the inclusion in the additional system cooling fan unit for discharging an auxiliary stream of air.
PyCOOL — A Cosmological Object-Oriented Lattice code written in Python
NASA Astrophysics Data System (ADS)
Sainio, J.
2012-04-01
There are a number of different phenomena in the early universe that have to be studied numerically with lattice simulations. This paper presents a graphics processing unit (GPU) accelerated Python program called PyCOOL that solves the evolution of scalar fields in a lattice with very precise symplectic integrators. The program has been written with the intention to hit a sweet spot of speed, accuracy and user friendliness. This has been achieved by using the Python language with the PyCUDA interface to make a program that is easy to adapt to different scalar field models. In this paper we derive the symplectic dynamics that govern the evolution of the system and then present the implementation of the program in Python and PyCUDA. The functionality of the program is tested in a chaotic inflation preheating model, a single field oscillon case and in a supersymmetric curvaton model which leads to Q-ball production. We have also compared the performance of a consumer graphics card to a professional Tesla compute card in these simulations. We find that the program is not only accurate but also very fast. To further increase the usefulness of the program we have equipped it with numerous post-processing functions that provide useful information about the cosmological model. These include various spectra and statistics of the fields. The program can be additionally used to calculate the generated curvature perturbation. The program is publicly available under GNU General Public License at https://github.com/jtksai/PyCOOL. Some additional information can be found from http://www.physics.utu.fi/tiedostot/theory/particlecosmology/pycool/.
Geomagnetic fluctuations during a polarity transition
NASA Astrophysics Data System (ADS)
Audunsson, Haraldur; Levi, Shaul
1997-01-01
The extensive Roza Member of the Columbia River Basalt Group (Washington State) has intermediate paleomagnetic directions, bracketed by underlying normal and overlying reverse polarity flows. A consistent paleomagnetic direction was measured at 11 widely distributed outcrops; the average direction has a declination of 189° and an inclination of -5°, with greater variation in the inclination [Rietman, 1966]. In this study the Roza Member was sampled in two Pasco Basin drillcores, where it is a single cooling unit and its thickness exceeds 50 m. Excellent core recovery allowed uniform and dense sampling of the drillcores. During its protracted cooling, the Roza flow in the drillcores recorded part of a 15.5 Ma geomagnetic polarity transition. The inclination has symmetric, quasicyclic intraflow variation, while the declination is nearly constant, consistent with the results from the outcrops. Thermal models of the cooling flow provide the timing for remanence acquisition. The inclination is inferred to have progressed from 0° to -15° and back to -3°over a period of 15 to 60 years, at rates of 1.6° to 0.5°/yr. Because the geomagnetic intensity was probably weak during the transition, these apparently high rates of change are not significantly different from present-day secular variation. These results agree with the hypothesis that normal secular variation persists through geomagnetic transitions. The Iow-amplitude quasicyclical fluctuations of the field over tens of years, recorded by Roza, suggest that the geomagnetic field reverses in discrete steps, and that more than 15-60 years were required to complete this reversal.
Glossary of terms and table of conversion factors used in design of chemical propulsion systems
NASA Technical Reports Server (NTRS)
Keller, R. B., Jr. (Compiler)
1979-01-01
The glossary presented is based entirely on terms used in the monographs on Chemical Propulsion. Significant terms relating to material properties and to material fabrication are presented. The terms are arranged in alphabetical order, with multiple word terms appearing in the normal sequence of usage; for example, ablative cooling appears as such, not as cooling, ablative, and lip seal appears as such, not as seal, lip. Conversion Factors for converting U.S. customary units to the International System of Units are presented in alphabetical order of the physical quantity (e.g., density, heat flux, specific impulse) involved.
NASA Astrophysics Data System (ADS)
Berg, H. P.; Pfaff, K.; Hennecke, D. K.
The resultant effects on the cooling effectiveness at the leading edge area of an impingement-cooled turbine vane by varying certain geometrical parameters is described with reference to local internal heat transfer coefficients determined from experiment and temperature calculations. The local heat transfer on the cooling-air side is determined experimentally with the aid of the analogy between heat- and mass transfer. The impingement cooling is provided from an inserted sheet-metal containing a single row of holes. The Reynolds Number and several of the cooling geometry parameters were varied. The results demonstrate the high local resolution of the method of measurement, which allows improved analytical treatment of the leading-edge cooling configuration. These experiments also point to the necessity of not always performing model tests under idealized conditions. This becomes very clear in the case of the tests performed on an application-oriented impingement-cooling configuration like that often encountered in engine manufacture. In conclusion, as an example, temperature calculations are employed to demonstrate the effect on the cooling effectiveness of varying the distances between insert and inner surface of the leading edge. It shows how the effectiveness of the leading edge cooling can be increased by simple geometrical measures, which results in a considerable improvement in service life.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-08
... industrial use. Potable water in the area is supplied to residents either through the Scriba Water District... and drift losses from the cooling tower. NMP2 has its own cooling water intake and discharge... service water system and makeup to the circulating water system to replace evaporation and drift losses...
ERIC Educational Resources Information Center
WHITESIDES, M.M.
THIS REPORT IS A COMPILATION OF DATA ON ELECTRIC AIR CONDITIONING COSTS, OPERATIONS AND MAINTENANCE. AIR CONDITIONING UNITS ARE COMPARED IN TERMS OF ELECTRIC VERSUS NON-ELECTRIC, AUTOMATIC VERSUS OPERATED, AIR COOLED VERSUS WATER COOLED, RECIPROCATING VERSUS CENTRIFUGAL COMPRESSORS, SPACE AND NOISE, REHEAT, MAINTENANCE AND ORIGINAL COST. DATA ARE…
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-02
... Altherma system, which consists of an air-to-water heat pump that provides hydronic heating and cooling as... Altherma system consists of an air-to-water heat pump that provides hydronic space heating and cooling as well as domestic hot water functions. It operates either as a split system with the compressor unit...
Reciprocating Magnetic Refrigerator
NASA Technical Reports Server (NTRS)
Johnson, D. L.
1985-01-01
Unit cools to 4 K by adiabatic demagnetization. Two porous matrices of paramagnetic material gadolinium/gallium/garnet held in long piston called displacer, machined out of Micarta (phenol formaldehyde polymer). Holes in side of displacer allow heat-exchange fluid to flow to and through matrices within. Piston seals on displacer prevent substantial mixing of fluid in two loops. Magnetic refrigerator provides continuous rather than "one-shot" cooling.
77 FR 27804 - Entergy Operations, Inc.; Grand Gulf Nuclear Station, Unit 1
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-11
... modification to the auxiliary cooling tower and the addition of two 60-gallon lube oil tanks associated with... modification of the auxiliary cooling tower and the addition of two 60-gallon lube oil tanks for the new radial... Mississippi River water is the Southeast Wood Fiber company located at the Claiborne County Port facility, 0.8...
Hot melt adhesive pad surface attachment assembly concept for on-orbit operations
NASA Technical Reports Server (NTRS)
Progar, D. J.; Stein, B. A.
1984-01-01
The use of a hot melt adhesive concept to develop a Surface Attachment Assembly (SAA) for on-orbit attachment and detachment operations for the Manned Maneuvering Unit (MMU) was investigated. The concept involved impregnation of the hot melt adhesive into a fiberglass covered pad which contained electrical heating and thermoelectric cooling devices. The polyamide hot melt adhesive selected can be repeatedly heated to its melting point in a vacuum and provide good adhesion to various surfaces, i.e., reusable surface insulation tiles, metals, and composites, when cooled. After a series of adhesive screening tests, Jet-Melt 3746 was selected from a group of commercially available thermoplastic adhesive candidates which met or exceeded many of the criteria established for the SAA system. The SAA system was designed and fabricted with the goal of proving the concept with a working model rather than attempting to optimize all facets of the system. This system evolved by investigating alternate attachment concepts, designing and fabricating electronic systems to heat and cool the adhesive, and then fabricating electronic systems to heat and cool the adhesive, and then fabricating and testing two prototype full-size units.
Yu, Shaocai; Alapaty, Kiran; Mathur, Rohit; Pleim, Jonathan; Zhang, Yuanhang; Nolte, Chris; Eder, Brian; Foley, Kristen; Nagashima, Tatsuya
2014-11-06
Aerosols can influence the climate indirectly by acting as cloud condensation nuclei and/or ice nuclei, thereby modifying cloud optical properties. In contrast to the widespread global warming, the central and south central United States display a noteworthy overall cooling trend during the 20(th) century, with an especially striking cooling trend in summertime daily maximum temperature (Tmax) (termed the U.S. "warming hole"). Here we used observations of temperature, shortwave cloud forcing (SWCF), longwave cloud forcing (LWCF), aerosol optical depth and precipitable water vapor as well as global coupled climate models to explore the attribution of the "warming hole". We find that the observed cooling trend in summer Tmax can be attributed mainly to SWCF due to aerosols with offset from the greenhouse effect of precipitable water vapor. A global coupled climate model reveals that the observed "warming hole" can be produced only when the aerosol fields are simulated with a reasonable degree of accuracy as this is necessary for accurate simulation of SWCF over the region. These results provide compelling evidence of the role of the aerosol indirect effect in cooling regional climate on the Earth. Our results reaffirm that LWCF can warm both winter Tmax and Tmin.
Cooling Panel Optimization for the Active Cooling System of a Hypersonic Aircraft
NASA Technical Reports Server (NTRS)
Youn, B.; Mills, A. F.
1995-01-01
Optimization of cooling panels for an active cooling system of a hypersonic aircraft is explored. The flow passages are of rectangular cross section with one wall heated. An analytical fin-type model for incompressible flow in smooth-wall rectangular ducts with coupled wall conduction is proposed. Based on this model, the a flow rate of coolant to each design minimum mass flow rate or coolant for a single cooling panel is obtained by satisfying hydrodynamic, thermal, and Mach number constraints. Also, the sensitivity of the optimal mass flow rate of coolant to each design variable is investigated. In addition, numerical solutions for constant property flow in rectangular ducts, with one side rib-roughened and coupled wall conduction, are obtained using a k-epsilon and wall function turbulence model, these results are compared with predictions of the analytical model.
Variability and trends in dry day frequency and dry event length in the southwestern United States
McCabe, Gregory J.; Legates, David R.; Lins, Harry F.
2010-01-01
Daily precipitation from 22 National Weather Service first-order weather stations in the southwestern United States for water years 1951 through 2006 are used to examine variability and trends in the frequency of dry days and dry event length. Dry events with minimum thresholds of 10 and 20 consecutive days of precipitation with less than 2.54 mm are analyzed. For water years and cool seasons (October through March), most sites indicate negative trends in dry event length (i.e., dry event durations are becoming shorter). For the warm season (April through September), most sites also indicate negative trends; however, more sites indicate positive trends in dry event length for the warm season than for water years or cool seasons. The larger number of sites indicating positive trends in dry event length during the warm season is due to a series of dry warm seasons near the end of the 20th century and the beginning of the 21st century. Overall, a large portion of the variability in dry event length is attributable to variability of the El Niño–Southern Oscillation, especially for water years and cool seasons. Our results are consistent with analyses of trends in discharge for sites in the southwestern United States, an increased frequency in El Niño events, and positive trends in precipitation in the southwestern United States.
The population of single and binary white dwarfs of the Galactic bulge
NASA Astrophysics Data System (ADS)
Torres, S.; García-Berro, E.; Cojocaru, R.; Calamida, A.
2018-05-01
Recent Hubble Space Telescope observations have unveiled the white dwarf cooling sequence of the Galactic bulge. Although the degenerate sequence can be well fitted employing the most up-to-date theoretical cooling sequences, observations show a systematic excess of red objects that cannot be explained by the theoretical models of single carbon-oxygen white dwarfs of the appropriate masses. Here, we present a population synthesis study of the white dwarf cooling sequence of the Galactic bulge that takes into account the populations of both single white dwarfs and binary systems containing at least one white dwarf. These calculations incorporate state-of-the-art cooling sequences for white dwarfs with hydrogen-rich and hydrogen-deficient atmospheres, for both white dwarfs with carbon-oxygen and helium cores, and also take into account detailed prescriptions of the evolutionary history of binary systems. Our Monte Carlo simulator also incorporates all the known observational biases. This allows us to model with a high degree of realism the white dwarf population of the Galactic bulge. We find that the observed excess of red stars can be partially attributed to white dwarf plus main sequence binaries, and to cataclysmic variables or dwarf novae. Our best fit is obtained with a higher binary fraction and an initial mass function slope steeper than standard values, as well as with the inclusion of differential reddening and blending. Our results also show that the possible contribution of double degenerate systems or young and thick-discbulge stars is negligible.
NASA Astrophysics Data System (ADS)
Silin, V. A.; Zorin, V. M.; Tagirov, A. M.; Tregubova, O. I.; Belov, I. V.; Povarov, P. V.
2010-12-01
Main results obtained from calculations of the steam generator and thermal circuit of the steam turbine unit for a nuclear power unit with supercritical-pressure water coolant and integral layout are presented. The obtained characteristics point to the advisability of carrying out further developments of this promising nuclear power technology.
Solid-state transformations in the β-form of chlorpropamide on cooling to 100 K.
Drebushchak, Tatiana N; Drebushchak, Valeri A; Boldyreva, Elena V
2011-04-01
A single-crystal X-ray diffraction study of the effect of cooling down to 100 K on the β-form of chlorpropamide, 4-chloro-N-(propylaminocarbonyl)benzenesulfonamide, has revealed reversible phase transitions at ∼257 K and between 150 and 125 K: β (Pbcn, Z' = 1) ⇔ β(II) (P2/c, Z' = 2) ⇔ β(III) (P2/n, a' = 2a, Z' = 4); the sequence corresponds to cooling. Despite changes in the space group and number of symmetry-independent molecules, the volume per molecule changes continuously in the temperature range 100-300 K. The phase transition at ∼257 K is accompanied by non-merohedral twinning, which is preserved on further cooling and through the second phase transition, but the original single crystal does not crack. DSC (differential scanning calorimetry) and X-ray powder diffraction investigations confirm the phase transitions. Twinning disappears on heating as the reverse transformations take place. The second phase transition is related to a change in conformation of the alkyl tail from trans to gauche in 1/4 of the molecules, regularly distributed in the space. Possible reasons for the increase in Z' upon cooling are discussed in comparison to other reported examples of processes (crystallization, phase transitions) in which organic crystals with Z' > 1 have been formed. Implications for pharmaceutical applications are discussed. © 2011 International Union of Crystallography
Material Selection for Microchannel Heatsink: Conjugate Heat Transfer Simulation
NASA Astrophysics Data System (ADS)
Uday Kumar, A.; Javed, Arshad; Dubey, Satish K.
2018-04-01
Heat dissipation during the operation of electronic devices causes rise in temperature, which demands an effective thermal management for their performance, life and reliability. Single phase liquid cooling in microchannels is an effective and proven technology for electronics cooling. However, due to the ongoing trends of miniaturization and developments in the microelectronics technology, the future needs of heat flux dissipation rate are expected to rise to 1 kW/cm2. Air cooled systems are unable to meet this demand. Hence, liquid cooled heatsinks are preferred. This paper presents conjugate heat transfer simulation of single phase flow in microchannels with application to electronic cooling. The numerical model is simulated for different materials: copper, aluminium and silicon as solid and water as liquid coolant. The performances of microchannel heatsink are analysed for mass flow rate range of 20-40 ml/min. The investigation has been carried out on same size of electronic chip and heat flux in order to have comparative study of different materials. This paper is divided into two sections: fabrication techniques and numerical simulation for different materials. In the first part, a brief discussion of fabrication techniques of microchannel heatsink have been presented. The second section presents conjugate heat transfer simulation and parametric investigation for different material microchannel heatsink. The presented study and findings are useful for selection of materials for microchannel heatsink.
Residential Energy Consumption Survey (RECS)
2028-01-01
EIA administers the Residential Energy Consumption Survey (RECS) to a nationally representative sample of housing units. Traditionally, specially trained interviewers collect energy characteristics on the housing unit, usage patterns, and household demographics. Data include energy costs and usage for heating, cooling, appliances and other end uses.
NASA Astrophysics Data System (ADS)
Ushakov, A. D.; Esin, A. A.; Chezganov, D. S.; Turygin, A. P.; Akhmatkhanov, A. R.; Hu, Q.; Sun, L.; Wei, X.; Shur, V. Ya
2017-10-01
The evolution of the domain structure during in-field cooling was in situ studied in [001]-cut single crystals of relaxor ferroelectric (1-x)Pb(Mg1/3Nb2/3)O3-xPbTiO3 (PMN-PT) with x = 0.33 with maximum of dielectric permittivity at 150°C. The main stages of domain evolution have been separated. The visualization of the static as-grown and polarized domain structures with high spatial resolution by piezoresponse force microscopy and scanning electron microscopy allowed measuring the characteristic features of maze and needle-like domain structures.
Methods for calculating conjugate problems of heat transfer
NASA Astrophysics Data System (ADS)
Kalinin, E. K.; Dreitser, G. A.; Kostiuk, V. V.; Berlin, I. I.
Methods are examined for calculating various conjugate problems of heat transfer in channels and closed vessels in cases of single-phase and two-phase flow in steady and unsteady conditions. The single-phase-flow studies involve the investigation of gaseous and liquid heat-carriers in pipes, annular and plane channels, and pipe bundles in cases of cooling and heating. General relationships are presented for heat transfer in cases of film, transition, and nucleate boiling, as well as for boiling crises. Attention is given to methods for analyzing the filling and cooling of conduits and tanks by cryogenic liquids; and ways to intensify heat transfer in these conditions are examined.
Method for preparation and readout of polyatomic molecules in single quantum states
NASA Astrophysics Data System (ADS)
Patterson, David
2018-03-01
Polyatomic molecular ions contain many desirable attributes of a useful quantum system, including rich internal degrees of freedom and highly controllable coupling to the environment. To date, the vast majority of state-specific experimental work on molecular ions has concentrated on diatomic species. The ability to prepare and read out polyatomic molecules in single quantum states would enable diverse experimental avenues not available with diatomics, including new applications in precision measurement, sensitive chemical and chiral analysis at the single-molecule level, and precise studies of Hz-level molecular tunneling dynamics. While cooling the motional state of a polyatomic ion via sympathetic cooling with a laser-cooled atomic ion is straightforward, coupling this motional state to the internal state of the molecule has proven challenging. Here we propose a method for readout and projective measurement of the internal state of a trapped polyatomic ion. The method exploits the rich manifold of technically accessible rotational states in the molecule to realize robust state preparation and readout with far less stringent engineering than quantum logic methods recently demonstrated on diatomic molecules. The method can be applied to any reasonably small (≲10 atoms) polyatomic ion with an anisotropic polarizability.
Lagasse, Lisa P; Love, David C; Smith, Katherine Clegg
2014-01-01
The country-of-origin labeling (COOL) law requires United States grocers to indicate the origin and procurement method (farm-raised or wild-caught) for seafood. This study explored the presentation of COOL on fresh, frozen, packaged, and unpackaged seafood in Baltimore City grocery stores. Eight stores were visited bi-monthly to photograph seafood labels, and circulars were collected weekly from fourteen stores over three months. Ninety-six percent of products were labeled correctly. Forty-eight percent of advertisements included COOL. While in-store labels did not highlight COOL, advertising featured references to domestic and wild-caught seafood, signaling to customers that these are high-value product qualities.
Barranco-Medina, Sergio; López-Jaramillo, Francisco Javier; Bernier-Villamor, Laura; Sevilla, Francisca; Lázaro, Juan José
2006-07-01
A cDNA encoding an open reading frame of 199 amino acids corresponding to a type II peroxiredoxin from Pisum sativum with its transit peptide was isolated by RT-PCR. The 171-amino-acid mature protein (estimated molecular weight 18.6 kDa) was cloned into the pET3d vector and overexpressed in Escherichia coli. The recombinant protein was purified and crystallized by the hanging-drop vapour-diffusion technique. A full data set (98.2% completeness) was collected using a rotating-anode generator to a resolution of 2.8 angstroms from a single crystal flash-cooled at 100 K. X-ray data revealed that the protein crystallizes in space group P1, with unit-cell parameters a = 61.88, b = 66.40, c = 77.23 angstroms, alpha = 102.90, beta = 104.40, gamma = 99.07 degrees, and molecular replacement using a theoretical model predicted from the primary structure as a search model confirmed the presence of six molecules in the unit cell as expected from the Matthews coefficient. Refinement of the structure is in progress.
Design and demonstration of a storage assisted air conditioning system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1982-04-01
One phase-change material, sodium sulfate decahydrate, has generated considerable interest for thermal storage. A form of this material containing salts to adjust the transition point to approximately 55/sup 0/F and a gelling agent to prevent segregation of the salts has been developed. This material is packaged in the form of a CHUB, (a cylinder two inches in diameter and twenty inches long) having a weight of 3.25 pounds and a thermal storage capability of 50 Btu per pound. Under this project, a storage-assisted (partial storage) air conditioning system was designed, installed, monitored and evaluated in a typical residential application. Thismore » feasibility demonstration was conducted under the direction of the Long Island Lighting Company in a single family residence in Melville, Long Island, New York. The demonstration system consisted of a CHUB thermal storage system utilized in conjunction with a one and one-half ton air conditioning unit to cool a house that would normally require a two and one half ton air conditioning unit.« less
Integrated turbomachine oxygen plant
Anand, Ashok Kumar; DePuy, Richard Anthony; Muthaiah, Veerappan
2014-06-17
An integrated turbomachine oxygen plant includes a turbomachine and an air separation unit. One or more compressor pathways flow compressed air from a compressor through one or more of a combustor and a turbine expander to cool the combustor and/or the turbine expander. An air separation unit is operably connected to the one or more compressor pathways and is configured to separate the compressed air into oxygen and oxygen-depleted air. A method of air separation in an integrated turbomachine oxygen plant includes compressing a flow of air in a compressor of a turbomachine. The compressed flow of air is flowed through one or more of a combustor and a turbine expander of the turbomachine to cool the combustor and/or the turbine expander. The compressed flow of air is directed to an air separation unit and is separated into oxygen and oxygen-depleted air.
Long Term Outdoor Testing of Low Concentration Solar Modules
NASA Astrophysics Data System (ADS)
Fraas, Lewis; Avery, James; Minkin, Leonid; Huang, H. X.; Hebrink, Tim; Hurt, Rik; Boehm, Robert
2011-12-01
A 1-axis carousel tracker equipped with four 3-sun low-concentration mirror modules has now been under test outdoors at the University of Nevada in Las Vegas (UNLV) for three years. There are three unique features associated with this unit. First, simple linear mirrors are used to reduce the amount of expensive single crystal silicon in order to potentially lower the module cost while potentially maintaining cell efficiencies over 20% and high module efficiency. Simple linear mirrors also allow the use of a single axis tracker. Second, the azimuth carousel tracker is also unique allowing trackers to be used on commercial building rooftops. Third, an experiment is underway comparing aluminum based mirrors with novel 3M Company multilayer polymeric mirrors which are potentially very low cost. Comparing the data from March of 2008 through March of 2011 shows that the aluminum mirror degradation to date is negligible and that the carousel tracker has been operating continuously and reliable. Also, no degradation has been observed for the 3M brand cool mirrors after one year in use.
Development of a valved non-lubricated linear compressor for compact 2K Gifford-McMahon cryocoolers
NASA Astrophysics Data System (ADS)
Hiratsuka, Y.; Bao, Q.; Xu, M.
2017-02-01
Recently, a new, compact Gifford-McMahon (GM) cryocooler for cooling superconducting single photon detectors (SSPD) has been developed and reported by Sumitomo Heavy Industries, Ltd. (SHI) [1]. It was reported that National Institute of Information and Communications Technology (NICT) developed a multi-channel SSPD system in which two or more channels were mounted on a GM cryocooler, and achieved a world-top-class performance [2]. However, the applications of such SSPD system were restricted due to its relatively large size and power consumption compared with a semiconductor system. Owing to the development of an SSPD system with a portable cryocooler system which can be installed in a vehicle, it is possible to apply such system to the optical communication of AdHoc [3], and to flexibly construct a large capacity optical line in a time of disaster. For such system, the size and power consumption reduction becomes indispensable. The objective is to reduce the total height of the expander by 33% relative to the existing RDK-101 GM expander and to reduce the total volume of the compressor unit by 50% relative to the existing CNA-11 compressor. In addition, considering the targeted cooling application, we set the design temperature targets of the first and the second stages to 1 W and 20 mW of heat load at 60 K and 2.3 K, respectively. In 2015, Hiratsuka reported that a new valved non-lubricated compressor was developed for a 2K GM cryocooler [4]. The cooling performance of a 2K GM expander operated by an experimental unit of the linear compressor was measured, and preliminary experiments were conducted. No-load temperature was 2.19 K, with 1 W and 14 mW heat load, the temperature was 48 K at the first stage and 2.3 K at the second stage, with an input power of about 1.2 kW. After that, the compressor efficiency has been improved by reducing losses, and the compressor input power has been reduced by 25%. The detailed experimental results are discussed in this paper.
Quantitative Data Analysis To Determine Best Food Cooling Practices in U.S. Restaurants†
Schaffner, Donald W.; Brown, Laura Green; Ripley, Danny; Reimann, Dave; Koktavy, Nicole; Blade, Henry; Nicholas, David
2017-01-01
Data collected by the Centers for Disease Control and Prevention (CDC) show that improper cooling practices contributed to more than 500 foodborne illness outbreaks associated with restaurants or delis in the United States between 1998 and 2008. CDC's Environmental Health Specialists Network (EHS-Net) personnel collected data in approximately 50 randomly selected restaurants in nine EHS-Net sites in 2009 to 2010 and measured the temperatures of cooling food at the beginning and the end of the observation period. Those beginning and ending points were used to estimate cooling rates. The most common cooling method was refrigeration, used in 48% of cooling steps. Other cooling methods included ice baths (19%), room-temperature cooling (17%), ice-wand cooling (7%), and adding ice or frozen food to the cooling food as an ingredient (2%). Sixty-five percent of cooling observations had an estimated cooling rate that was compliant with the 2009 Food and Drug Administration Food Code guideline (cooling to 41°F [5°C] in 6 h). Large cuts of meat and stews had the slowest overall estimated cooling rate, approximately equal to that specified in the Food Code guideline. Pasta and noodles were the fastest cooling foods, with a cooling time of just over 2 h. Foods not being actively monitored by food workers were more than twice as likely to cool more slowly than recommended in the Food Code guideline. Food stored at a depth greater than 7.6 cm (3 in.) was twice as likely to cool more slowly than specified in the Food Code guideline. Unventilated cooling foods were almost twice as likely to cool more slowly than specified in the Food Code guideline. Our data suggest that several best cooling practices can contribute to a proper cooling process. Inspectors unable to assess the full cooling process should consider assessing specific cooling practices as an alternative. Future research could validate our estimation method and study the effect of specific practices on the full cooling process. PMID:25836405
Air Distribution Retrofit Strategies for Affordable Housing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dentz, J.; Conlin, F.; Holloway, Parker
2014-03-01
In multifamily and attached buildings, traditional duct sealing methods are often impractical or costly and disruptive because of the difficulty in accessing leakage sites. In this project, two retrofit duct sealing techniques, manually-applied sealants and injecting a spray sealant, were implemented in several low-rise multiunit buildings. An analysis on the cost and performance of the two methods are presented. Each method was used in twenty housing units: approximately half of each group of units are single story and the remainder are two story. Results show that duct leakage to the outside was reduced by an average of 59% through themore » use of manual methods, and by 90% in the units where the injected spray sealant was used. It was found that 73% of the leakage reduction in homes that were treated with injected spray sealant was attributable to the manual sealing done at boots, returns and the air handler. The cost of manually-applying sealant ranged from $275 to $511 per unit and for the injected spray sealant the cost was $700 per unit. Modeling suggests a simple payback of 2.2 years for manual sealing and 4.7 years for the injected spray sealant system. Utility bills were collected for one year before and after the retrofits. Utility bill analysis shows 14% and 16% energy savings using injected spray sealant system and hand sealing procedure respectively in heating season whereas in cooling season, energy savings using injected spray sealant system and hand sealing were both 16%.« less
Sideband cooling of small ion Coulomb crystals in a Penning trap
NASA Astrophysics Data System (ADS)
Stutter, G.; Hrmo, P.; Jarlaud, V.; Joshi, M. K.; Goodwin, J. F.; Thompson, R. C.
2018-03-01
We have recently demonstrated the laser cooling of a single ? ion to the motional ground state in a Penning trap using the resolved-sideband cooling technique on the electric quadrupole transition S? D?. Here we report on the extension of this technique to small ion Coulomb crystals made of two or three ? ions. Efficient cooling of the axial motion is achieved outside the Lamb-Dicke regime on a two-ion string along the magnetic field axis as well as on two- and three-ion planar crystals. Complex sideband cooling sequences are required in order to cool both axial degrees of freedom simultaneously. We measure a mean excitation after cooling of ? for the centre of mass (COM) mode and ? for the breathing mode of the two-ion string with corresponding heating rates of 11(2) ? and ? at a trap frequency of 162 kHz. The occupation of the ground state of the axial modes (?) is above 75% for the two-ion planar crystal and the associated heating rates 0.8(5) ? at a trap frequency of 355 kHz.
Legionnaires' Disease Outbreaks and Cooling Towers, New York City, New York, USA.
Fitzhenry, Robert; Weiss, Don; Cimini, Dan; Balter, Sharon; Boyd, Christopher; Alleyne, Lisa; Stewart, Renee; McIntosh, Natasha; Econome, Andrea; Lin, Ying; Rubinstein, Inessa; Passaretti, Teresa; Kidney, Anna; Lapierre, Pascal; Kass, Daniel; Varma, Jay K
2017-11-01
The incidence of Legionnaires' disease in the United States has been increasing since 2000. Outbreaks and clusters are associated with decorative, recreational, domestic, and industrial water systems, with the largest outbreaks being caused by cooling towers. Since 2006, 6 community-associated Legionnaires' disease outbreaks have occurred in New York City, resulting in 213 cases and 18 deaths. Three outbreaks occurred in 2015, including the largest on record (138 cases). Three outbreaks were linked to cooling towers by molecular comparison of human and environmental Legionella isolates, and the sources for the other 3 outbreaks were undetermined. The evolution of investigation methods and lessons learned from these outbreaks prompted enactment of a new comprehensive law governing the operation and maintenance of New York City cooling towers. Ongoing surveillance and program evaluation will determine if enforcement of the new cooling tower law reduces Legionnaires' disease incidence in New York City.
Legionnaires’ Disease Outbreaks and Cooling Towers, New York City, New York, USA
Fitzhenry, Robert; Cimini, Dan; Balter, Sharon; Boyd, Christopher; Alleyne, Lisa; Stewart, Renee; McIntosh, Natasha; Econome, Andrea; Lin, Ying; Rubinstein, Inessa; Passaretti, Teresa; Kidney, Anna; Lapierre, Pascal; Kass, Daniel; Varma, Jay K.
2017-01-01
The incidence of Legionnaires’ disease in the United States has been increasing since 2000. Outbreaks and clusters are associated with decorative, recreational, domestic, and industrial water systems, with the largest outbreaks being caused by cooling towers. Since 2006, 6 community-associated Legionnaires’ disease outbreaks have occurred in New York City, resulting in 213 cases and 18 deaths. Three outbreaks occurred in 2015, including the largest on record (138 cases). Three outbreaks were linked to cooling towers by molecular comparison of human and environmental Legionella isolates, and the sources for the other 3 outbreaks were undetermined. The evolution of investigation methods and lessons learned from these outbreaks prompted enactment of a new comprehensive law governing the operation and maintenance of New York City cooling towers. Ongoing surveillance and program evaluation will determine if enforcement of the new cooling tower law reduces Legionnaires’ disease incidence in New York City. PMID:29049017
Design and Analysis of a Two-Stage Adsorption Air Chiller
NASA Astrophysics Data System (ADS)
Benrajesh, P.; Rajan, A. John
2017-05-01
The objective of this article is to design and build a bio-friendly air-conditioner, by using adsorption method in the presence of 15% of calcium carbide in water. Aluminum sheet metals are used to form three identical tunnels, to pass the air for processing. Exhaust heat generated from the dairy sterilizing unit process is reutilized, for cooling the environment through this equipment. This equipment is designed, and the analysis is carried out to quantify the COP, SCP, and cooling power. Heat exchangers are designed; its Performance Parameters are quantified and correlated with the conventional designs. It is observed that the new adsorption chiller can produce the coefficient of performance of chiller as 1.068; the Specific cooling power of 10.66 (W/Kg); and the Cooling power of 4.2 KW. This equipment needs 0 to 15 minutes to reach the desired cool breeze (24°c) from the existing room temperature (29°c).
NASA Astrophysics Data System (ADS)
Indra Siswantara, Ahmad; Pujowidodo, Hariyotejo; Darius, Asyari; Ramdlan Gunadi, Gun Gun
2018-03-01
This paper presents the mathematical modeling analysis on cooling system in a combined cycle power plant. The objective of this study is to get the impact of cooling water upsurge on plant performance and operation, using Engineering Equation Solver (EES™) tools. Power plant installed with total power capacity of block#1 is 505.95 MWe and block#2 is 720.8 MWe, where sea water consumed as cooling media at two unit condensers. Basic principle of analysis is heat balance calculation from steam turbine and condenser, concern to vacuum condition and heat rate values. Based on the result shown graphically, there were impact the upsurge of cooling water to increase plant heat rate and vacuum pressure in condenser so ensued decreasing plant efficiency and causing possibility steam turbine trip as back pressure raised from condenser.
A 1.8K refrigeration cryostat with 100 hours continuous cooling
NASA Astrophysics Data System (ADS)
Xu, Dong; Li, Jian; Huang, Rongjin; Li, Laifeng
2017-02-01
A refrigeration cryostat has been developed to produce continuous cooling to a sample below 1.8 K over 100 hours by using a cryocooler. A two-stage 4K G-M cryocooler is used to liquefy helium gas from evacuated vapor and cylinder helium bottle which can be replaced during the cooling process. The liquid helium transfer into superfluid helium in a Joule-Thomson valve in connection with a 1000 m3/h pumping unit. The pressure of evacuated helium vapor is controlled by air bag and valves. A copper decompression chamber, which is designed as a cooling station to control the superfluid helium, is used to cool the sample attached on it uniformly. The sample connects to the copper chamber in cryostat with screw thread. The cryostat can reach the temperature of 1.7 K without load and the continuous working time is more than 100 hours.
Solar heating and cooling of buildings
NASA Technical Reports Server (NTRS)
Bourke, R. D.; Davis, E. S.
1975-01-01
Solar energy has been used for space heating and water heating for many years. A less common application, although technically feasible, is solar cooling. This paper describes the techniques employed in the heating and cooling of buildings, and in water heating. The potential for solar energy to displace conventional energy sources is discussed. Water heating for new apartments appears to have some features which could make it a place to begin the resurgence of solar energy applications in the United States. A project to investigate apartment solar water heating, currently in the pilot plant construction phase, is described.
NASA Astrophysics Data System (ADS)
Wang, Jingwei; Zhu, Pengfei; Liu, Hui; Liang, Xuejie; Wu, Dihai; Liu, Yalong; Yu, Dongshan; Zah, Chung-en; Liu, Xingsheng
2017-02-01
High power diode lasers have been widely used in many fields. To meet the requirements of high power and high reliability, passively cooled single bar CS-packaged diode lasers must be robust to withstand thermal fatigue and operate long lifetime. In this work, a novel complete indium-free double-side cooling technology has been applied to package passively cooled high power diode lasers. Thermal behavior of hard solder CS-package diode lasers with different packaging structures was simulated and analyzed. Based on these results, the device structure and packaging process of double-side cooled CS-packaged diode lasers were optimized. A series of CW 200W 940nm high power diode lasers were developed and fabricated using hard solder bonding technology. The performance of the CW 200W 940nm high power diode lasers, such as output power, spectrum, thermal resistance, near field, far field, smile, lifetime, etc., is characterized and analyzed.
Simulation Studies on Cooling of Cryogenic Propellant by Gas Bubbling
NASA Astrophysics Data System (ADS)
Sandilya, Pavitra; Saha, Pritam; Sengupta, Sonali
Injection cooling was proposed to store cryogenic liquids (Larsen et al. [1], Schmidt [2]). When a non-condensable gas is injected through a liquid, the liquid component would evaporate into the bubble if its partial pressure in the bubble is lower than its vapour pressure. This would tend to cool the liquid. Earlier works on injection cooling was analysed by Larsen et al. [1], Schmidt [2], Cho et al. [3] and Jung et al. [4], considering instantaneous mass transfer and finite heat transfer between gas bubble and liquid. It is felt that bubble dynamics (break up, coalescence, deformation, trajectory etc.) should also play a significant role in liquid cooling. The reported work are based on simple assumptions like single bubble, zero bubble deformation, and no inter-bubble interactions. Hence in this work, we propose a lumped parameter model considering both heat and mass interactions between bubble and the liquid to gain a preliminary insight into the cooling phenomenon during gas injection through a liquid.
Billings, Jay Jay; Deyton, Jordan H.; Forest Hull, S.; ...
2015-07-17
Building new fission reactors in the United States presents many technical and regulatory challenges. Chief among the technical challenges is the need to share and present results from new high- fidelity, high- performance simulations in an easily consumable way. In light of the modern multi-scale, multi-physics simulations can generate petabytes of data, this will require the development of new techniques and methods to reduce the data to familiar quantities of interest with a more reasonable resolution and size. Furthermore, some of the results from these simulations may be new quantities for which visualization and analysis techniques are not immediately availablemore » in the community and need to be developed. Our paper describes a new system for managing high-performance simulation results in a domain-specific way that naturally exposes quantities of interest for light water and sodium-cooled fast reactors. It enables easy qualitative and quantitative comparisons between simulation results with a graphical user interface and cross-platform, multi-language input- output libraries for use by developers to work with the data. One example comparing results from two different simulation suites for a single assembly in a light-water reactor is presented along with a detailed discussion of the system s requirements and design.« less
NASA Astrophysics Data System (ADS)
Ault, A. P.; Bondy, A. L.; Nhliziyo, M. V.; Bertman, S. B.; Pratt, K.; Shepson, P. B.
2013-12-01
During the summer, the southeastern United States experiences a cooling haze due to the interaction of anthropogenic and biogenic aerosol sources. An objective of the summer 2013 Southern Oxidant and Aerosol Study (SOAS) was to improve our understanding of how trace gases and aerosols are contributing to this relative cooling through light scattering and absorption. To improve understanding of biogenic-anthropogenic interactions through secondary organic aerosol (SOA) formation on primary aerosol cores requires detailed physicochemical characterization of the particles after uptake and processing. Our measurements focus on single particle analysis of aerosols in the accumulation mode (300-1000 nm) collected using a multi orifice uniform deposition impactor (MOUDI) at the Centreville, Alabama SEARCH site. Particles were characterized using an array of microscopic and spectroscopic techniques, including: scanning electron microscopy (SEM), transmission electron microscopy (TEM), energy dispersive X-ray analysis (EDX), and Raman microspectroscopy. These analyses provide detailed information on particle size, morphology, elemental composition, and functional groups. This information is combined with mapping capabilities to explore individual particle spatial patterns and how that impacts structural characteristics. The improved understanding will be used to explore how sources and processing (such as SOA coating of soot) change particle structure (i.e. core shell) and how the altered optical properties impact air quality/climate effects on a regional scale.
Dynamical backaction cooling with free electrons.
Niguès, A; Siria, A; Verlot, P
2015-09-18
The ability to cool single ions, atomic ensembles, and more recently macroscopic degrees of freedom down to the quantum ground state has generated considerable progress and perspectives in fundamental and technological science. These major advances have been essentially obtained by coupling mechanical motion to a resonant electromagnetic degree of freedom in what is generally known as laser cooling. Here, we experimentally demonstrate the first self-induced coherent cooling mechanism that is not mediated by an electromagnetic resonance. Using a focused electron beam, we report a 50-fold reduction of the motional temperature of a nanowire. Our result primarily relies on the sub-nanometre confinement of the electron beam and generalizes to any delayed and spatially confined interaction, with important consequences for near-field microscopy and fundamental nanoscale dissipation mechanisms.
Code of Federal Regulations, 2012 CFR
2012-01-01
... venting, external cooling by an ancillary system, or operational controls during transport. Natural...: The International System of Units (SI) followed or preceded by U.S. standard or customary units. The U... water as a common, contract, or private carrier, or by civil aircraft. Certificate holder means a person...
Code of Federal Regulations, 2011 CFR
2011-01-01
... venting, external cooling by an ancillary system, or operational controls during transport. Natural...: The International System of Units (SI) followed or preceded by U.S. standard or customary units. The U... water as a common, contract, or private carrier, or by civil aircraft. Certificate holder means a person...
Comparison of cropland and forest surface temperatures across the conterminous United States
Global climate models (GCM) investigating the effects of land cover on climate have found that replacing extra-tropical forest with cropland promotes cooling. We compared cropland and forest surface temperatures across the continental United States in 16 cells that were approxim...
Code of Federal Regulations, 2010 CFR
2010-01-01
... venting, external cooling by an ancillary system, or operational controls during transport. Natural...: The International System of Units (SI) followed or preceded by U.S. standard or customary units. The U... water as a common, contract, or private carrier, or by civil aircraft. Certificate holder means a person...
iMAST Quarterly, Number 3, 2000
2000-01-01
components which depend on evaporating unit capabilities. There are three components (EB-gun, water cooled copper crucible and vacuum chamber) in the EB-PVD...Ion Implantation and Ion Plating electromagnetic deflected through 180 or 2700. Similarly, evaporant material is placed in a water-cooled copper ... crucible , which could be either pocket type for small quantity evaporation application or continuous ingot feeding through the crucible for larger quantity
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hrycushko, B; Chopra, R; Futch, C
Purpose: The protective effects of induced or even accidental hypothermia on the human body are widespread with several medical uses currently under active research. In vitro experiments using human cell lines have shown hypothermia provides a radioprotective effect that becomes more pronounced at large, single-fraction doses common to SBRT treatments. Relevant to prostate SBRT, this work details the fabrication and testing of a 3D-printed cooling device to facilitate the investigation of the radioprotective effect of local hypothermia on the rat rectum. Methods: A 3cm long, two-channel rectal cooling device was designed in SOLIDWORKS CAD for 3D printing. The water intakemore » nozzle is connected to a 1mm diameter brass pipe from which water flows and circulates back around to the exit nozzle. Both nozzles are connected by plastic tubing to a water chiller pump. Following leak-proof testing, fiber optic temperature probes were used to evaluate the temperature over time when placed adjacent to the cooling device within a rat rectum. MRI thermometry characterized the relative temperature distribution in concentric ROIs surrounding the probe. CBCT images from a small-animal irradiator were evaluated for imaging artifacts which could affect Monte Carlo dose calculations during treatment planning. Results: The rectal temperature adjacent to the cooling device decreased from body temperature (37°C) to 15°C in 10–20 minutes from device insertion. Rectal temperature was maintained at 15±3°C during active cooling. MRI thermometry tests revealed a steep temperature gradient with increasing distance from the cooling device, with the desired temperature range maintained within the surrounding few millimeters. Conclusion: A 3D printed rectal cooling device was fabricated for the purpose of inducing local hypothermia in rat rectums. Rectal cooling capabilities were characterized in-vivo to facilitate an investigation of the radioprotective effect of hypothermia for late rectal toxicity following a single large dose of radiation. Funding support provided by RSNA research seed grant.« less
NASA Technical Reports Server (NTRS)
Quijada, Manuel A.; Threat, Felix; Garrison, Matt; Perrygo, Chuck; Bousquet, Robert; Rashford, Robert
2008-01-01
The James Webb Space Telescope (JWST) consists of an infrared-optimized Optical Telescope Element (OTE) that is cooled down to 40 degrees Kelvin. A second adjacent component to the OTE is the Integrated Science Instrument Module, or ISIM. This module includes the electronic compartment, which provides the mounting surfaces and ambient thermally controlled environment for the instrument control electronics. Dissipating the 200 watts generated from the ISIM structure away from the OTE is of paramount importance so that the spacecraft's own heat does not interfere with the infrared light detected from distant cosmic sources. This technical challenge is overcome by a thermal subsystem unit that provides passive cooling to the ISIM control electronics. The proposed design of this thermal radiator consists of a lightweight structure made out of composite materials and low-emittance metal coatings. In this paper, we will present characterizations of the coating emittance, bidirectional reflectance, and mechanical structure design that will affect the performance of this passive cooling system.
Loss of DHR sequences at Browns Ferry Unit One - accident-sequence analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cook, D.H.; Grene, S.R.; Harrington, R.M.
1983-05-01
This study describes the predicted response of Unit One at the Browns Ferry Nuclear Plant to a postulated loss of decay heat removal (DHR) capability following scram from full power with the power conversion system unavailable. In accident sequences without DHR capability, the residual heat removal (RHR) system functions of pressure suppression pool cooling and reactor vessel shutdown cooling are unavailable. Consequently, all decay heat energy is stored in the pressure suppression pool with a concomitant increase in pool temperature and primary containment pressure. With the assumption that DHR capability is not regained during the lengthy course of this accidentmore » sequence, the containment ultimately fails by overpressurization. Although unlikely, this catastrophic failure might lead to loss of the ability to inject cooling water into the reactor vessel, causing subsequent core uncovery and meltdown. The timing of these events and the effective mitigating actions that might be taken by the operator are discussed in this report.« less
Structured laser gain-medium by new bonding for power micro-laser
NASA Astrophysics Data System (ADS)
Kausas, Arvydas; Zheng, Lihe; Taira, Takunori
2017-02-01
In this work, we have compared the Q-switched performance of single rod crystal to a newly developed distributed face cooling structure. This structure was made by surface activated bonding technology and allowed to combine transparent heatsink to a gain crystal at room temperature. The Sapphire and Nd3+:YAG crystal plates were combined in this fashion to produce eight crystal chip which was further used to obtain Q-switch pulses with Cr4+:YAG crystal as saturable absorber. Energy of 9 mJ and pulse duration of 815 ps were achieved. Although the energy obtained with single rod system was 10 mJ, the degradation of the beam prevents such crystal to be used in further applications. This is the first demonstration of distributed face cooling system outperformed conventionally single rod system.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Hui; School of Physics, University of Chinese Academy of Sciences, Beijing 100049; Yin, Mojuan
2015-10-12
In this paper, we report on the active filtering and amplification of a single mode from an optical femtosecond laser comb with mode spacing of 250 MHz by optical injection of two external-cavity diode lasers operating in cascade to build a narrow linewidth laser for laser cooling of the strontium atoms in an optical lattice clock. Despite the low injection of individual comb mode of approximately 50 nW, a single comb line at 689 nm could be filtered and amplified to reach as high as 10 mW with 37 dB side mode suppression and a linewidth of 240 Hz. This method could be appliedmore » over a broad spectral band to build narrow linewidth lasers for various applications.« less
An alternative cooling system to enhance the safety of Li-ion battery packs
NASA Astrophysics Data System (ADS)
Kizilel, Riza; Sabbah, Rami; Selman, J. Robert; Al-Hallaj, Said
A passive thermal management system is evaluated for high-power Li-ion packs under stressful or abusive conditions, and compared with a purely air-cooling mode under normal and abuse conditions. A compact and properly designed passive thermal management system utilizing phase change material (PCM) provides faster heat dissipation than active cooling during high pulse power discharges while preserving sufficiently uniform cell temperature to ensure the desirable cycle life for the pack. This study investigates how passive cooling with PCM contributes to preventing the propagation of thermal runaway in a single cell or adjacent cells due to a cell catastrophic failure. Its effectiveness is compared with that of active cooling by forced air flow or natural convection using the same compact module and pack configuration corresponding to the PCM matrix technology. The effects of nickel tabs and spacing between the cells were also studied.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Andorf, M. B.; Lebedev, V. A.; Piot, P.
2015-06-01
Optical stochastic cooling (OSC) is a method of beam cooling which is expected to provide cooling rates orders of magnitude larger than ordinary stochastic cooling. Light from an undulator (the pickup) is amplified and fed back onto the particle beam via another undulator (the kicker). Fermilab is currently exploring a possible proof-of-principle experiment of the OSC at the integrable-optics test accelerator (IOTA) ring. To implement effective OSC a good correction of phase distortions in the entire band of the optical amplifier is required. In this contribution we present progress in experimental characterization of phase distortions associated to a Titanium Sapphiremore » crystal laser-gain medium (a possible candidate gain medium for the OSC experiment to be performed at IOTA). We also discuss a possible option for a mid-IR amplifier« less
Routine sampling and the control of Legionella spp. in cooling tower water systems.
Bentham, R H
2000-10-01
Cooling water samples from 31 cooling tower systems were cultured for Legionella over a 16-week summer period. The selected systems were known to be colonized by Legionella. Mean Legionella counts and standard deviations were calculated and time series correlograms prepared for each system. The standard deviations of Legionella counts in all the systems were very large, indicating great variability in the systems over the time period. Time series analyses demonstrated that in the majority of cases there was no significant relationship between the Legionella counts in the cooling tower at time of collection and the culture result once it was available. In the majority of systems (25/28), culture results from Legionella samples taken from the same systems 2 weeks apart were not statistically related. The data suggest that determinations of health risks from cooling towers cannot be reliably based upon single or infrequent Legionella tests.
Method and apparatus for a catalytic firebox reactor
Smith, Lance L.; Etemad, Shahrokh; Ulkarim, Hasan; Castaldi, Marco J.; Pfefferle, William C.
2001-01-01
A catalytic firebox reactor employing an exothermic catalytic reaction channel and multiple cooling conduits for creating a partially reacted fuel/oxidant mixture. An oxidation catalyst is deposited on the walls forming the boundary between the multiple cooling conduits and the exothermic catalytic reaction channel, on the side of the walls facing the exothermic catalytic reaction channel. This configuration allows the oxidation catalyst to be backside cooled by any fluid passing through the cooling conduits. The heat of reaction is added to both the fluid in the exothermic catalytic reaction channel and the fluid passing through the cooling conduits. After discharge of the fluids from the exothermic catalytic reaction channel, the fluids mix to create a single combined flow. A further innovation in the reactor incorporates geometric changes in the exothermic catalytic reaction channel to provide streamwise variation of the velocity of the fluids in the reactor.
Structural cooling fluid tube for supporting a turbine component and supplying cooling fluid
DOE Office of Scientific and Technical Information (OSTI.GOV)
Charron, Richard; Pierce, Daniel
2015-02-24
A shaft cover support for a gas turbine engine is disclosed. The shaft cover support not only provides enhanced support to a shaft cover of the gas turbine engine, but also includes a cooling fluid chamber for passing fluids from a rotor air cooling supply conduit to an inner ring cooling manifold. As such, the shaft cover support accomplishes in a single component what was only partially accomplished in two components in conventional configurations. The shaft cover support may also provide additional stiffness and reduce interference of the flow from the compressor. In addition, the shaft cover support accommodates amore » transition section extending between compressor and turbine sections of the engine. The shaft cover support has a radially extending region that is offset from the inlet and outlet that enables the shaft cover support to surround the transition, thereby reducing the overall length of this section of the engine.« less
Effect of tropospheric aerosols upon atmospheric infrared cooling rates
NASA Technical Reports Server (NTRS)
Harshvardhan, MR.; Cess, R. D.
1978-01-01
The effect of tropospheric aerosols on atmospheric infrared cooling rates is investigated by the use of recent models of infrared gaseous absorption. A radiative model of the atmosphere that incorporates dust as an absorber and scatterer of infrared radiation is constructed by employing the exponential kernel approximation to the radiative transfer equation. Scattering effects are represented in terms of a single scattering albedo and an asymmetry factor. The model is applied to estimate the effect of an aerosol layer made of spherical quartz particles on the infrared cooling rate. Calculations performed for a reference wavelength of 0.55 microns show an increased greenhouse effect, where the net upward flux at the surface is reduced by 10% owing to the strongly enhanced downward emission. There is a substantial increase in the cooling rate near the surface, but the mean cooling rate throughout the lower troposphere was only 10%.
Design Optimization of a Thermoelectric Cooling Module Using Finite Element Simulations
NASA Astrophysics Data System (ADS)
Abid, Muhammad; Somdalen, Ragnar; Rodrigo, Marina Sancho
2018-05-01
The thermoelectric industry is concerned about the size reduction, cooling performance and, ultimately, the production cost of thermoelectric modules. Optimization of the size and performance of a commercially available thermoelectric cooling module is considered using finite element simulations. Numerical simulations are performed on eight different three-dimensional geometries of a single thermocouple, and the results are further extended for a whole module as well. The maximum temperature rise at the hot and cold sides of a thermocouple is determined by altering its height and cross-sectional area. The influence of the soldering layer is analyzed numerically using temperature dependent and temperature independent thermoelectric properties of the solder material and the semiconductor pellets. Experiments are conducted to test the cooling performance of the thermoelectric module and the results are compared with the results obtained through simulations. Finally, cooling rate and maximum coefficient of performance (COPmax) are computed using convective and non-convective boundary conditions.
Internal-Film Cooling of Rocket Nozzles
NASA Technical Reports Server (NTRS)
Sloop, J L; Kinney, George R
1948-01-01
Experiments were conducted with 1000-pound-thrust rocket engine to determine feasibility of cooling convergent-divergent nozzle by internal film of water introduced at nozzle entrance. Water flow of 3 percent of propellant flow reduced heat flow into nozzle to 55 percent of uncooled heat flow. Introduction of water by porous ring before nozzle resulted in more uniform coverage of nozzle than water introduced by single arrangement of 36 jets directed along nozzle wall. Water flow through porous ring of 3.5 percent of propellant flow stabilized wall temperature in convergent section but did not adequately cool throat or divergent sections.
NASA Technical Reports Server (NTRS)
1980-01-01
The solar energy system installed in the building has 2,978 sq ft of single axis tracking, concentrating collectors and provides solar energy for space heating, space cooling and domestic hot water. A 1,200,000 Btu/hour water tube gas boiler provides hot water for space heating. Space cooling is provided by a 100 ton hot water fired absorption chiller. Domestic hot water heating is provided by a 50 gallon natural gas domestic storage water heater. Extracts from the site files, specification references, drawings, installation, operation and maintenance instructions are included.
Charge recombination in the muon collider cooling channel
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fernow, R. C.; Palmer, R. B.
2012-12-21
The final stage of the ionization cooling channel for the muon collider must transversely recombine the positively and negatively charged bunches into a single beam before the muons can be accelerated. It is particularly important to minimize any emittance growth in this system since no further cooling takes place before the bunches are collided. We have found that emittance growth could be minimized by using symmetric pairs of bent solenoids and careful matching. We show that a practical design can be found that has transmission {approx}99%, emittance growth less than 0.1%, and minimal dispersion in the recombined bunches.
Cooling of a Bose-Einstein Condensate by Spin Distillation.
Naylor, B; Maréchal, E; Huckans, J; Gorceix, O; Pedri, P; Vernac, L; Laburthe-Tolra, B
2015-12-11
We propose and experimentally demonstrate a new cooling mechanism leading to purification of a Bose-Einstein condensate (BEC). Our scheme starts with a BEC polarized in the lowest energy spin state. Spin excited states are thermally populated by lowering the single particle energy gap set by the magnetic field. Then, these spin-excited thermal components are filtered out, which leads to an increase of the BEC fraction. We experimentally demonstrate such cooling for a spin 3 ^{52}Cr dipolar BEC. Our scheme should be applicable to Na or Rb, with the perspective to reach temperatures below 1 nK.