14 CFR 417.309 - Flight safety system analysis.
Code of Federal Regulations, 2012 CFR
2012-01-01
... system anomaly occurring and all of its effects as determined by the single failure point analysis and... termination system. (c) Single failure point. A command control system must undergo an analysis that... fault tree analysis or a failure modes effects and criticality analysis; (2) Identify all possible...
14 CFR 417.309 - Flight safety system analysis.
Code of Federal Regulations, 2010 CFR
2010-01-01
... system anomaly occurring and all of its effects as determined by the single failure point analysis and... termination system. (c) Single failure point. A command control system must undergo an analysis that... fault tree analysis or a failure modes effects and criticality analysis; (2) Identify all possible...
14 CFR 417.309 - Flight safety system analysis.
Code of Federal Regulations, 2013 CFR
2013-01-01
... system anomaly occurring and all of its effects as determined by the single failure point analysis and... termination system. (c) Single failure point. A command control system must undergo an analysis that... fault tree analysis or a failure modes effects and criticality analysis; (2) Identify all possible...
14 CFR 417.309 - Flight safety system analysis.
Code of Federal Regulations, 2014 CFR
2014-01-01
... system anomaly occurring and all of its effects as determined by the single failure point analysis and... termination system. (c) Single failure point. A command control system must undergo an analysis that... fault tree analysis or a failure modes effects and criticality analysis; (2) Identify all possible...
14 CFR 417.309 - Flight safety system analysis.
Code of Federal Regulations, 2011 CFR
2011-01-01
... system anomaly occurring and all of its effects as determined by the single failure point analysis and... termination system. (c) Single failure point. A command control system must undergo an analysis that... fault tree analysis or a failure modes effects and criticality analysis; (2) Identify all possible...
Adaptive Connectivity Restoration from Node Failure(s) in Wireless Sensor Networks
Wang, Huaiyuan; Ding, Xu; Huang, Cheng; Wu, Xiaobei
2016-01-01
Recently, there is a growing interest in the applications of wireless sensor networks (WSNs). A set of sensor nodes is deployed in order to collectively survey an area of interest and/or perform specific surveillance tasks in some of the applications, such as battlefield reconnaissance. Due to the harsh deployment environments and limited energy supply, nodes may fail, which impacts the connectivity of the whole network. Since a single node failure (cut-vertex) will destroy the connectivity and divide the network into disjoint blocks, most of the existing studies focus on the problem of single node failure. However, the failure of multiple nodes would be a disaster to the whole network and must be repaired effectively. Only few studies are proposed to handle the problem of multiple cut-vertex failures, which is a special case of multiple node failures. Therefore, this paper proposes a comprehensive solution to address the problems of node failure (single and multiple). Collaborative Single Node Failure Restoration algorithm (CSFR) is presented to solve the problem of single node failure only with cooperative communication, but CSFR-M, which is the extension of CSFR, handles the single node failure problem more effectively with node motion. Moreover, Collaborative Connectivity Restoration Algorithm (CCRA) is proposed on the basis of cooperative communication and node maneuverability to restore network connectivity after multiple nodes fail. CSFR-M and CCRA are reactive methods that initiate the connectivity restoration after detecting the node failure(s). In order to further minimize the energy dissipation, CCRA opts to simplify the recovery process by gridding. Moreover, the distance that an individual node needs to travel during recovery is reduced by choosing the nearest suitable candidates. Finally, extensive simulations validate the performance of CSFR, CSFR-M and CCRA. PMID:27690030
Anthology of the Development of Radiation Transport Tools as Applied to Single Event Effects
NASA Astrophysics Data System (ADS)
Reed, R. A.; Weller, R. A.; Akkerman, A.; Barak, J.; Culpepper, W.; Duzellier, S.; Foster, C.; Gaillardin, M.; Hubert, G.; Jordan, T.; Jun, I.; Koontz, S.; Lei, F.; McNulty, P.; Mendenhall, M. H.; Murat, M.; Nieminen, P.; O'Neill, P.; Raine, M.; Reddell, B.; Saigné, F.; Santin, G.; Sihver, L.; Tang, H. H. K.; Truscott, P. R.; Wrobel, F.
2013-06-01
This anthology contains contributions from eleven different groups, each developing and/or applying Monte Carlo-based radiation transport tools to simulate a variety of effects that result from energy transferred to a semiconductor material by a single particle event. The topics span from basic mechanisms for single-particle induced failures to applied tasks like developing websites to predict on-orbit single event failure rates using Monte Carlo radiation transport tools.
Destructive Single-Event Failures in Schottky Diodes
NASA Technical Reports Server (NTRS)
Casey, Megan C.; Lauenstein, Jean-Marie; Gigliuto, Robert A.; Wilcox, Edward P.; Phan, Anthony M.; Kim, Hak; Chen, Dakai; LaBel, Kenneth A.
2014-01-01
This presentation contains test results for destructive failures in DC-DC converters. We have shown that Schottky diodes are susceptible to destructive single-event effects. Future work will be completed to identify parameter that determines diode susceptibility.
Destructive Single-Event Effects in Diodes
NASA Technical Reports Server (NTRS)
Casey, Megan C.; Lauenstein, Jean-Marie; Campola, Michael J.; Wilcox, Edward P.; Phan, Anthony M.; Label, Kenneth A.
2017-01-01
In this work, we discuss the observed single-event effects in a variety of types of diodes. In addition, we conduct failure analysis on several Schottky diodes that were heavy-ion irradiated. High- and low-magnitude optical microscope images, infrared camera images, and scanning electron microscope images are used to identify and describe the failure locations.
NASA Technical Reports Server (NTRS)
Chen, Dakai; Phan, Anthony; Kim, Hak; Swonger, James; Musil, Paul; LaBel, Kenneth
2013-01-01
We show examples of single event functional interrupt and destructive failure in modern POL devices. The increasing complexity and diversity of the design and process introduce hard SEE modes that are triggered by various mechanisms.
Destructive Single-Event Failures in Diodes
NASA Technical Reports Server (NTRS)
Casey, Megan C.; Gigliuto, Robert A.; Lauenstein, Jean-Marie; Wilcox, Edward P.; Kim, Hak; Chen, Dakai; Phan, Anthony M.; LaBel, Kenneth A.
2013-01-01
In this summary, we have shown that diodes are susceptible to destructive single-event effects, and that these failures occur along the guard ring. By determining the last passing voltages, a safe operating area can be derived. By derating off of those values, rather than by the rated voltage, like what is currently done with power MOSFETs, we can work to ensure the safety of future missions. However, there are still open questions about these failures. Are they limited to a single manufacturer, a small number, or all of them? Is there a threshold rated voltage that must be exceeded to see these failures? With future work, we hope to answer these questions. In the full paper, laser results will also be presented to verify that failures only occur along the guard ring.
NASA Technical Reports Server (NTRS)
Arakere, N. K.; Swanson, G.
2002-01-01
High cycle fatigue (HCF) induced failures in aircraft gas turbine and rocket engine turbopump blades is a pervasive problem. Single crystal nickel turbine blades are being utilized in rocket engine turbopumps and jet engines throughout industry because of their superior creep, stress rupture, melt resistance, and thermomechanical fatigue capabilities over polycrystalline alloys. Currently the most widely used single crystal turbine blade superalloys are PWA 1480/1493, PWA 1484, RENE' N-5 and CMSX-4. These alloys play an important role in commercial, military and space propulsion systems. Single crystal materials have highly orthotropic properties making the position of the crystal lattice relative to the part geometry a significant factor in the overall analysis. The failure modes of single crystal turbine blades are complicated to predict due to the material orthotropy and variations in crystal orientations. Fatigue life estimation of single crystal turbine blades represents an important aspect of durability assessment. It is therefore of practical interest to develop effective fatigue failure criteria for single crystal nickel alloys and to investigate the effects of variation of primary and secondary crystal orientation on fatigue life. A fatigue failure criterion based on the maximum shear stress amplitude /Delta(sub tau)(sub max))] on the 24 octahedral and 6 cube slip systems, is presented for single crystal nickel superalloys (FCC crystal). This criterion reduces the scatter in uniaxial LCF test data considerably for PWA 1493 at 1200 F in air. Additionally, single crystal turbine blades used in the alternate advanced high-pressure fuel turbopump (AHPFTP/AT) are modeled using a large-scale three-dimensional finite element model. This finite element model is capable of accounting for material orthotrophy and variation in primary and secondary crystal orientation. Effects of variation in crystal orientation on blade stress response are studied based on 297 finite element model runs. Fatigue lives at critical points in the blade are computed using finite element stress results and the failure criterion developed. Stress analysis results in the blade attachment region are also presented. Results presented demonstrates that control of secondary and primary crystallographic orientation has the potential to significantly increase a component S resistance to fatigue crack growth with- out adding additional weight or cost. [DOI: 10.1115/1.1413767
NASA Technical Reports Server (NTRS)
Schmeckpeper, K. R.
1987-01-01
The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA approach features a top-down analysis of the hardware to determine failure modes, criticality, and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. This report documents the independent analysis results corresponding to the Orbiter Electrical Power Distribution and Control (EPD and C) hardware. The EPD and C hardware performs the functions of distributing, sensing, and controlling 28 volt DC power and of inverting, distributing, sensing, and controlling 117 volt 400 Hz AC power to all Orbiter subsystems from the three fuel cells in the Electrical Power Generation (EPG) subsystem. Each level of hardware was evaluated and analyzed for possible failure modes and effects. Criticality was assigned based upon the severity of the effect for each failure mode. Of the 1671 failure modes analyzed, 9 single failures were determined to result in loss of crew or vehicle. Three single failures unique to intact abort were determined to result in possible loss of the crew or vehicle. A possible loss of mission could result if any of 136 single failures occurred. Six of the criticality 1/1 failures are in two rotary and two pushbutton switches that control External Tank and Solid Rocket Booster separation. The other 6 criticality 1/1 failures are fuses, one each per Aft Power Control Assembly (APCA) 4, 5, and 6 and one each per Forward Power Control Assembly (FPCA) 1, 2, and 3, that supply power to certain Main Propulsion System (MPS) valves and Forward Reaction Control System (RCS) circuits.
A new yield and failure theory for composite materials under static and dynamic loading
Daniel, Isaac M.; Daniel, Sam M.; Fenner, Joel S.
2017-09-12
In order to facilitate and accelerate the process of introducing, evaluating and adopting new material systems, it is important to develop/establish comprehensive and effective procedures of characterization, modeling and failure prediction of composite structures based on the properties of the constituent materials, e. g., fibers, matrix, and the single ply or lamina. A new yield/failure theory is proposed for predicting lamina yielding and failure under multi-axial states of stress including strain rate effects. It is based on the equivalent stress concept derived from energy principles and is expressed in terms of a single criterion. It is presented in the formmore » of master yield and failure envelopes incorporating strain rate effects. The theory can be further adapted and extended to the prediction of in situ first ply yielding and failure (FPY and FPF) and progressive damage of multi-directional laminates under static and dynamic loadings. The significance of this theory is that it allows for rapid screening of new composite materials without extensive testing and offers easily implemented design tools.« less
A new yield and failure theory for composite materials under static and dynamic loading
DOE Office of Scientific and Technical Information (OSTI.GOV)
Daniel, Isaac M.; Daniel, Sam M.; Fenner, Joel S.
In order to facilitate and accelerate the process of introducing, evaluating and adopting new material systems, it is important to develop/establish comprehensive and effective procedures of characterization, modeling and failure prediction of composite structures based on the properties of the constituent materials, e. g., fibers, matrix, and the single ply or lamina. A new yield/failure theory is proposed for predicting lamina yielding and failure under multi-axial states of stress including strain rate effects. It is based on the equivalent stress concept derived from energy principles and is expressed in terms of a single criterion. It is presented in the formmore » of master yield and failure envelopes incorporating strain rate effects. The theory can be further adapted and extended to the prediction of in situ first ply yielding and failure (FPY and FPF) and progressive damage of multi-directional laminates under static and dynamic loadings. The significance of this theory is that it allows for rapid screening of new composite materials without extensive testing and offers easily implemented design tools.« less
Thompson, Keith A; Morrissey, Ryan P; Phan, Anita; Schwarz, Ernst R
2012-08-01
To determine the effects of the US economy on heart failure hospitalization rates. The recession was associated with worsening unemployment, loss of private insurance and prescription medication benefits, medication nonadherence, and ultimately increased rates of hospitalization for heart failure. We compared hospitalization rates at a large, single, academic medical center from July 1, 2006 to February 28, 2007, a time of economic stability, and July 1, 2008 to February 28, 2009, a time of economic recession in the United States. Significantly fewer patients had private medical insurance during the economic recession than during the control period (36.5% vs 46%; P = 0.04). Despite this, there were no differences in the heart failure hospitalization or readmission rates, length of hospitalization, need for admission to an intensive care unit, in-hospital mortality, or use of guideline-recommended heart failure medications between the 2 study periods. We conclude that despite significant effects on medical insurance coverage, rates of heart failure hospitalization at our institution were not significantly affected by the recession. Additional large-scale population-based research is needed to better understand the effects of fluctuations in the US economy on heart failure hospitalization rates. © 2012 Wiley Periodicals, Inc.
What Reliability Engineers Should Know about Space Radiation Effects
NASA Technical Reports Server (NTRS)
DiBari, Rebecca
2013-01-01
Space radiation in space systems present unique failure modes and considerations for reliability engineers. Radiation effects is not a one size fits all field. Threat conditions that must be addressed for a given mission depend on the mission orbital profile, the technologies of parts used in critical functions and on application considerations, such as supply voltages, temperature, duty cycle, and redundancy. In general, the threats that must be addressed are of two types-the cumulative degradation mechanisms of total ionizing dose (TID) and displacement damage (DD). and the prompt responses of components to ionizing particles (protons and heavy ions) falling under the heading of single-event effects. Generally degradation mechanisms behave like wear-out mechanisms on any active components in a system: Total Ionizing Dose (TID) and Displacement Damage: (1) TID affects all active devices over time. Devices can fail either because of parametric shifts that prevent the device from fulfilling its application or due to device failures where the device stops functioning altogether. Since this failure mode varies from part to part and lot to lot, lot qualification testing with sufficient statistics is vital. Displacement damage failures are caused by the displacement of semiconductor atoms from their lattice positions. As with TID, failures can be either parametric or catastrophic, although parametric degradation is more common for displacement damage. Lot testing is critical not just to assure proper device fi.mctionality throughout the mission. It can also suggest remediation strategies when a device fails. This paper will look at these effects on a variety of devices in a variety of applications. This paper will look at these effects on a variety of devices in a variety of applications. (2) On the NEAR mission a functional failure was traced to a PIN diode failure caused by TID induced high leakage currents. NEAR was able to recover from the failure by reversing the current of a nearby Thermal Electric Cooler (turning the TEC into a heater). The elevated temperature caused the PIN diode to anneal and the device to recover. It was by lot qualification testing that NEAR knew the diode would recover when annealed. This paper will look at these effects on a variety of devices in a variety of applications. Single Event Effects (SEE): (1) In contrast to TID and displacement damage, Single Event Effects (SEE) resemble random failures. SEE modes can range from changes in device logic (single-event upset, or SEU). temporary disturbances (single-event transient) to catastrophic effects such as the destructive SEE modes, single-event latchup (SEL). single-event gate rupture (SEGR) and single-event burnout (SEB) (2) The consequences of nondestructive SEE modes such as SEU and SET depend critically on their application--and may range from trivial nuisance errors to catastrophic loss of mission. It is critical not just to ensure that potentially susceptible devices are well characterized for their susceptibility, but also to work with design engineers to understand the implications of each error mode. -For destructive SEE, the predominant risk mitigation strategy is to avoid susceptible parts, or if that is not possible. to avoid conditions under which the part may be susceptible. Destructive SEE mechanisms are often not well understood, and testing is slow and expensive, making rate prediction very challenging. (3) Because the consequences of radiation failure and degradation modes depend so critically on the application as well as the component technology, it is essential that radiation, component. design and system engineers work togetherpreferably starting early in the program to ensure critical applications are addressed in time to optimize the probability of mission success.
NASA Technical Reports Server (NTRS)
Feldstein, J. F.
1977-01-01
Failure data from 16 commercial spacecraft were analyzed to evaluate failure trends, reliability growth, and effectiveness of tests. It was shown that the test programs were highly effective in ensuring a high level of in-orbit reliability. There was only a single catastrophic problem in 44 years of in-orbit operation on 12 spacecraft. The results also indicate that in-orbit failure rates are highly correlated with unit and systems test failure rates. The data suggest that test effectiveness estimates can be used to guide the content of a test program to ensure that in-orbit reliability goals are achieved.
Single-Event Effects in Silicon and Silicon Carbide Power Devices
NASA Technical Reports Server (NTRS)
Lauenstein, Jean-Marie; Casey, Megan C.; LaBel, Kenneth A.; Topper, Alyson D.; Wilcox, Edward P.; Kim, Hak; Phan, Anthony M.
2014-01-01
NASA Electronics Parts and Packaging program-funded activities over the past year on single-event effects in silicon and silicon carbide power devices are presented, with focus on SiC device failure signatures.
Effects of space radiation on electronic microcircuits
NASA Technical Reports Server (NTRS)
Kolasinski, W. A.
1989-01-01
The single event effects or phenomena (SEP), which so far have been observed as events falling on one or another of the SE classes: Single Event Upset (SEU), Single Event Latchup (SEL) and Single Event Burnout (SEB), are examined. Single event upset is defined as a lasting, reversible change in the state of a multistable (usually bistable) electronic circuit such as a flip-flop or latch. In a computer memory, SEUs manifest themselves as unexplained bit flips. Since latchup is in general caused by a single event of short duration, the single event part of the SEL term is superfluous. Nevertheless, it is used customarily to differentiate latchup due to a single heavy charged particle striking a sensitive cell from more ordinary kinds of latchup. Single event burnout (SEB) refers usually to total instantaneous failure of a power FET when struck by a single particle, with the device shorting out the power supply. An unforeseen failure of these kinds can be catastrophic to a space mission, and the possibilities are discussed.
Independent Orbiter Assessment (IOA): Analysis of the purge, vent and drain subsystem
NASA Technical Reports Server (NTRS)
Bynum, M. C., III
1987-01-01
The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA approach features a top-down analysis of the hardware to determine failure modes, criticality, and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. This report documents the independent analysis results corresponding to the Orbiter PV and D (Purge, Vent and Drain) Subsystem hardware. The PV and D Subsystem controls the environment of unpressurized compartments and window cavities, senses hazardous gases, and purges Orbiter/ET Disconnect. The subsystem is divided into six systems: Purge System (controls the environment of unpressurized structural compartments); Vent System (controls the pressure of unpressurized compartments); Drain System (removes water from unpressurized compartments); Hazardous Gas Detection System (HGDS) (monitors hazardous gas concentrations); Window Cavity Conditioning System (WCCS) (maintains clear windows and provides pressure control of the window cavities); and External Tank/Orbiter Disconnect Purge System (prevents cryo-pumping/icing of disconnect hardware). Each level of hardware was evaluated and analyzed for possible failure modes and effects. Criticality was assigned based upon the severity of the effect for each failure mode. Four of the sixty-two failure modes analyzed were determined as single failures which could result in the loss of crew or vehicle. A possible loss of mission could result if any of twelve single failures occurred. Two of the criticality 1/1 failures are in the Window Cavity Conditioning System (WCCS) outer window cavity, where leakage and/or restricted flow will cause failure to depressurize/repressurize the window cavity. Two criticality 1/1 failures represent leakage and/or restricted flow in the Orbiter/ET disconnect purge network which prevent cryopumping/icing of disconnect hardware. Each level of hardware was evaluated and analyzed for possible failure modes and effects. Criticality was assigned based upon the severity of the effect for each failure mode.
NASA Astrophysics Data System (ADS)
Gan, Luping; Li, Yan-Feng; Zhu, Shun-Peng; Yang, Yuan-Jian; Huang, Hong-Zhong
2014-06-01
Failure mode, effects and criticality analysis (FMECA) and Fault tree analysis (FTA) are powerful tools to evaluate reliability of systems. Although single failure mode issue can be efficiently addressed by traditional FMECA, multiple failure modes and component correlations in complex systems cannot be effectively evaluated. In addition, correlated variables and parameters are often assumed to be precisely known in quantitative analysis. In fact, due to the lack of information, epistemic uncertainty commonly exists in engineering design. To solve these problems, the advantages of FMECA, FTA, fuzzy theory, and Copula theory are integrated into a unified hybrid method called fuzzy probability weighted geometric mean (FPWGM) risk priority number (RPN) method. The epistemic uncertainty of risk variables and parameters are characterized by fuzzy number to obtain fuzzy weighted geometric mean (FWGM) RPN for single failure mode. Multiple failure modes are connected using minimum cut sets (MCS), and Boolean logic is used to combine fuzzy risk priority number (FRPN) of each MCS. Moreover, Copula theory is applied to analyze the correlation of multiple failure modes in order to derive the failure probabilities of each MCS. Compared to the case where dependency among multiple failure modes is not considered, the Copula modeling approach eliminates the error of reliability analysis. Furthermore, for purpose of quantitative analysis, probabilities importance weight from failure probabilities are assigned to FWGM RPN to reassess the risk priority, which generalize the definition of probability weight and FRPN, resulting in a more accurate estimation than that of the traditional models. Finally, a basic fatigue analysis case drawn from turbine and compressor blades in aeroengine is used to demonstrate the effectiveness and robustness of the presented method. The result provides some important insights on fatigue reliability analysis and risk priority assessment of structural system under failure correlations.
Ianiro, G; Valerio, L; Masucci, L; Pecere, S; Bibbò, S; Quaranta, G; Posteraro, B; Currò, D; Sanguinetti, M; Gasbarrini, A; Cammarota, G
2017-05-01
Faecal microbiota transplantation (FMT) is an effective treatment for recurrent Clostridium difficile infection (CDI). Although a single faecal infusion is usually sufficient to eradicate CDI, a considerable number of patients need multiple infusions to be cured. The aim of this study was to identify predictors of failure after single faecal infusion in patients with recurrent CDI. We included patients with recurrent CDI prospectively treated with FMT by colonoscopy. By means of univariate and multivariate analysis, variables including female gender, age, number of CDI recurrences, severity of CDI, hospitalization, inadequate bowel preparation, unrelated donor, and use of frozen faeces, were assessed to predict failure after single faecal infusion. Sixty-four patients (39 women; mean age 74 years) were included. Of them, 44 (69%) were cured by a single faecal infusion, whereas 20 (31%) needed repeat infusions. Overall, FMT cured 62 of 64 (97%) patients. In the subgroup of patients with severe CDI, only eight of 26 (30%) were cured with a single infusion. At multivariate analysis, severe CDI (OR 24.66; 95% CI 4.44-242.08; p 0.001) and inadequate bowel preparation (OR 11.53; 95% CI 1.71-115.51; p 0.019) were found to be independent predictors of failure after single faecal infusion. Severe CDI and inadequate bowel preparation appear to be independent predictors of failure after single faecal infusion in patients treated with FMT by colonoscopy for recurrent CDI. Our results may help to optimize protocols and outcomes of FMT in patients with recurrent CDI. Copyright © 2016 European Society of Clinical Microbiology and Infectious Diseases. Published by Elsevier Ltd. All rights reserved.
Improved Multi-Axial, Temperature and Time Dependent (MATT) Failure Model
NASA Technical Reports Server (NTRS)
Richardson, D. E.; Anderson, G. L.; Macon, D. J.
2002-01-01
An extensive effort has recently been completed by the Space Shuttle's Reusable Solid Rocket Motor (RSRM) nozzle program to completely characterize the effects of multi-axial loading, temperature and time on the failure characteristics of three filled epoxy adhesives (TIGA 321, EA913NA, EA946). As part of this effort, a single general failure criterion was developed that accounted for these effects simultaneously. This model was named the Multi- Axial, Temperature, and Time Dependent or MATT failure criterion. Due to the intricate nature of the failure criterion, some parameters were required to be calculated using complex equations or numerical methods. This paper documents some simple but accurate modifications to the failure criterion to allow for calculations of failure conditions without complex equations or numerical techniques.
Biomechanics of Polyhydroxyalkanoate Mesh-Augmented Single-Row Rotator Cuff Repairs.
Tashjian, Robert Z; Kolz, Christopher W; Suter, Thomas; Henninger, Heath B
Polyhydroxyalkanoate (PHA) mesh is a bioresorbable scaffold used to reinforce the suture-tendon interface in rotator cuff repairs (RCRs). We conducted a study of cyclic and ultimate failure properties of PHA mesh-augmented single-row RCRs and nonaugmented RCRs. Eight pairs of fresh-frozen cadaver humeri (6 male, 2 female) were tested. Mean (SD) age was 61 (9) years. The supraspinatus tendon was resected and reattached in a single-row configuration using 2 triple-loaded suture anchors and 6 simple stitches. The opposite humerus underwent RCR augmented with 2 strips of 13-mm × 23-mm PHA mesh. Humeri were mounted in an Instron load frame, cycled 1000 times to 1.0 MPa of effective stress, and loaded to failure. Construct gapping and ultimate failure loads/displacements were recorded. Paired t tests compared augmented and nonaugmented RCRs (P ≤ .05 was significant). There was no difference in gapping over 1000 cycles (P = .879). Mean (SD) failure load was higher for PHA mesh-augmented RCRs, 571 (173) N, than for nonaugmented (control) RCRs, 472 (120) N (P = .042), and failures were consistent within pairs because of tissue failure at the knots or anchor pullout. This technique for arthroscopic augmentation can be used to improve initial biomechanical repair strength in tears at risk for failure.
Meisel, Adam F; Henninger, Heath B; Barber, F Alan; Getelman, Mark H
2017-05-01
The purpose of this study was to evaluate the time zero cyclic and failure loading properties of a linked single-row rotator cuff repair compared with a standard simple suture single-row repair using triple-loaded suture anchors. Eighteen human cadaveric shoulders from 9 matched pairs were dissected, and full-thickness supraspinatus tears were created. The tendon cross-sectional area was recorded. In each pair, one side was repaired with a linked single-row construct and the other with a simple suture single-row construct, both using 2 triple-loaded suture anchors. After preloading, specimens were cycled to 1 MPa of effective stress at 1 Hz for 500 cycles, and gap formation was recorded with a digital video system. Samples were then loaded to failure, and modes of failure were recorded. There was no statistical difference in peak gap formation between the control and linked constructs (3.6 ± 0.9 mm and 3.6 ± 1.2 mm, respectively; P = .697). Both constructs averaged below a 5-mm cyclic failure threshold. There was no statistical difference in ultimate load to failure between the control and linked repair (511.1 ± 139.0 N and 561.2 ± 131.8 N, respectively; P = .164), and both groups reached failure at loads similar to previous studies. Constructs failed predominantly via tissue tearing parallel to the medial suture line. The linked repair performed similarly to the simple single-row repair. Both constructs demonstrated high ultimate load to failure and good resistance to gap formation with cyclic loading, validating the time zero strength of both constructs in a human cadaveric model. The linked repair provided equivalent resistance to gap formation and failure loads compared with simple suture single-row repairs with triple-loaded suture anchors. This suggests that the linked repair is a simplified rip-stop configuration using the existing suture that may perform similarly to current rotator cuff repair techniques. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Sano, Toshikazu; Ousaka, Daiki; Goto, Takuya; Ishigami, Shuta; Hirai, Kenta; Kasahara, Shingo; Ohtsuki, Shinichi; Sano, Shunji; Oh, Hidemasa
2018-03-30
Intracoronary administration of cardiosphere-derived cells (CDCs) in patients with single ventricles resulted in a short-term improvement in cardiac function. To test the hypothesis that CDC infusion is associated with improved cardiac function and reduced mortality in patients with heart failure. We evaluated the effectiveness of CDCs using an integrated cohort study in 101 patients with single ventricles, including 41 patients who received CDC infusion and 60 controls treated with staged palliation alone. Heart failure with preserved ejection fraction (EF) or reduced EF was stratified by the cardiac function after surgical reconstruction. The main outcome measure was to evaluate the magnitude of improvement in cardiac function and all-cause mortality at 2 years. Animal studies were conducted to clarify the underlying mechanisms of heart failure with preserved EF and heart failure with reduced EF phenotypes. At 2 years, CDC infusion increased ventricular function (stage 2: +8.4±10.0% versus +1.6±6.4%, P =0.03; stage 3: +7.9±7.5% versus -1.1±5.5%, P <0.001) compared with controls. In all available follow-up data, survival did not differ between the 2 groups (log-rank P =0.225), whereas overall patients treated by CDCs had lower incidences of late failure ( P =0.022), adverse events ( P =0.013), and catheter intervention ( P =0.005) compared with controls. CDC infusion was associated with a lower risk of adverse events (hazard ratio, 0.411; 95% CI, 0.179-0.942; P =0.036). Notably, CDC infusion reduced mortality ( P =0.038) and late complications ( P <0.05) in patients with heart failure with reduced EF but not with heart failure with preserved EF. CDC-treated rats significantly reversed myocardial fibrosis with differential collagen deposition and inflammatory responses between the heart failure phenotypes. CDC administration in patients with single ventricles showed favorable effects on ventricular function and was associated with reduced late complications except for all-cause mortality after staged procedures. Patients with heart failure with reduced EF but not heart failure with preserved EF treated by CDCs resulted in significant improvement in clinical outcome. URL: http://www.clinicaltrials.gov. Unique identifiers: NCT01273857 and NCT01829750. © 2018 American Heart Association, Inc.
Köberich, Stefan; Lohrmann, Christa; Mittag, Oskar; Dassen, Theo
2015-06-01
To evaluate the effects of a nurse-led, hospital-based heart failure specific education session with a three-month telephone follow-up on self-care behaviour, care dependency and quality of life for patients with chronic heart failure. Patient education in patients with heart failure is able to promote heart failure-specific self-care, to reduce mortality, morbidity and rehospitalisation rates and to enhance quality of life, especially if heart failure education is embedded in a multidisciplinary approach. Evidence of the effect of a nurse-led self-care education, quality of life and care dependency in addition to standard medical treatment in Germany is lacking. Nonblinded, prospective, single-centre, randomised controlled trial. Sixty-four patients were allocated either to the intervention group or to the control group. Patients in the intervention group received education about heart failure self-care with a consecutive telephone follow-up over three months in addition to standard medical treatment. Patients in the control group received standard medical treatment only. Data of 110 patients (58 in the intervention group and 52 in the control group) with a mean age of 62 years and mean left ventricular ejection fraction of 28·2% could be analysed. Self-care education had a significant influence on overall heart failure self-care but not on quality of life and care dependency. A single education session with a consecutive telephone follow-up is able to improve overall self-care behaviours but not quality of life. Care dependency was not influenced by the education session. The easy to implement and short educational intervention has a positive effect on self-care behaviour for patients with heart failure. However, there was no effect on quality of life and care dependency. To improve quality of life and to influence care dependency, different measures have to be applied. © 2015 John Wiley & Sons Ltd.
NASA Astrophysics Data System (ADS)
Khogeer, Ahmed Sirag
2005-11-01
Petroleum refining is a capital-intensive business. With stringent environmental regulations on the processing industry and declining refining margins, political instability, increased risk of war and terrorist attacks in which refineries and fuel transportation grids may be targeted, higher pressures are exerted on refiners to optimize performance and find the best combination of feed and processes to produce salable products that meet stricter product specifications, while at the same time meeting refinery supply commitments and of course making profit. This is done through multi objective optimization. For corporate refining companies and at the national level, Intea-Refinery and Inter-Refinery optimization is the second step in optimizing the operation of the whole refining chain as a single system. Most refinery-wide optimization methods do not cover multiple objectives such as minimizing environmental impact, avoiding catastrophic failures, or enhancing product spec upgrade effects. This work starts by carrying out a refinery-wide, single objective optimization, and then moves to multi objective-single refinery optimization. The last step is multi objective-multi refinery optimization, the objectives of which are analysis of the effects of economic, environmental, product spec, strategic, and catastrophic failure. Simulation runs were carried out using both MATLAB and ASPEN PIMS utilizing nonlinear techniques to solve the optimization problem. The results addressed the need to debottleneck some refineries or transportation media in order to meet the demand for essential products under partial or total failure scenarios. They also addressed how importing some high spec products can help recover some of the losses and what is needed in order to accomplish this. In addition, the results showed nonlinear relations among local and global objectives for some refineries. The results demonstrate that refineries can have a local multi objective optimum that does not follow the same trends as either global or local single objective optimums. Catastrophic failure effects on refinery operations and on local objectives are more significant than environmental objective effects, and changes in the capacity or the local objectives follow a discrete behavioral pattern, in contrast to environmental objective cases in which the effects are smoother. (Abstract shortened by UMI.)
NASA Technical Reports Server (NTRS)
Bonnice, W. F.; Wagner, E.; Motyka, P.; Hall, S. R.
1985-01-01
The performance of the detection filter in detecting and isolating aircraft control surface and actuator failures is evaluated. The basic detection filter theory assumption of no direct input-output coupling is violated in this application due to the use of acceleration measurements for detecting and isolating failures. With this coupling, residuals produced by control surface failures may only be constrained to a known plane rather than to a single direction. A detection filter design with such planar failure signatures is presented, with the design issues briefly addressed. In addition, a modification to constrain the residual to a single known direction even with direct input-output coupling is also presented. Both the detection filter and the modification are tested using a nonlinear aircraft simulation. While no thresholds were selected, both filters demonstrated an ability to detect control surface and actuator failures. Failure isolation may be a problem if there are several control surfaces which produce similar effects on the aircraft. In addition, the detection filter was sensitive to wind turbulence and modeling errors.
Thermal stress fracture of ceramic coatings
NASA Technical Reports Server (NTRS)
Andersson, C. A.
1983-01-01
Thermal stress failures of ceramic coatings are discussed in terms of fracture mechanics concepts. The effects of transient and residual stresses on single and multiple cycle failure mechanisms are considered. A specific example of a zirconia thermal barrier coating is presented and its endurance calculated using the proposed relationships.
Failure modes and effects analysis automation
NASA Technical Reports Server (NTRS)
Kamhieh, Cynthia H.; Cutts, Dannie E.; Purves, R. Byron
1988-01-01
A failure modes and effects analysis (FMEA) assistant was implemented as a knowledge based system and will be used during design of the Space Station to aid engineers in performing the complex task of tracking failures throughout the entire design effort. The three major directions in which automation was pursued were the clerical components of the FMEA process, the knowledge acquisition aspects of FMEA, and the failure propagation/analysis portions of the FMEA task. The system is accessible to design, safety, and reliability engineers at single user workstations and, although not designed to replace conventional FMEA, it is expected to decrease by many man years the time required to perform the analysis.
NASA Technical Reports Server (NTRS)
Arakere, Nagaraj K.; Swanson, Gregory R.
2000-01-01
High Cycle Fatigue (HCF) induced failures in aircraft gas-turbine engines is a pervasive problem affecting a wide range of components and materials. HCF is currently the primary cause of component failures in gas turbine aircraft engines. Turbine blades in high performance aircraft and rocket engines are increasingly being made of single crystal nickel superalloys. Single-crystal Nickel-base superalloys were developed to provide superior creep, stress rupture, melt resistance and thermomechanical fatigue capabilities over polycrystalline alloys previously used in the production of turbine blades and vanes. Currently the most widely used single crystal turbine blade superalloys are PWA 1480/1493 and PWA 1484. These alloys play an important role in commercial, military and space propulsion systems. PWA1493, identical to PWA1480, but with tighter chemical constituent control, is used in the NASA SSME (Space Shuttle Main Engine) alternate turbopump, a liquid hydrogen fueled rocket engine. Objectives for this paper are motivated by the need for developing failure criteria and fatigue life evaluation procedures for high temperature single crystal components, using available fatigue data and finite element modeling of turbine blades. Using the FE (finite element) stress analysis results and the fatigue life relations developed, the effect of variation of primary and secondary crystal orientations on life is determined, at critical blade locations. The most advantageous crystal orientation for a given blade design is determined. Results presented demonstrates that control of secondary and primary crystallographic orientation has the potential to optimize blade design by increasing its resistance to fatigue crack growth without adding additional weight or cost.
neutron-Induced Failures in semiconductor Devices
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wender, Stephen Arthur
2017-03-13
Single Event Effects are a very significant failure mode in modern semiconductor devices that may limit their reliability. Accelerated testing is important for semiconductor industry. Considerable more work is needed in this field to mitigate the problem. Mitigation of this problem will probably come from Physicists and Electrical Engineers working together
The Pardoning of Richard Nixon: A Failure in Motivational Strategy.
ERIC Educational Resources Information Center
Klumpp, James F.; Lukehart, Jeffrey K.
1978-01-01
Discusses the failure of Gerald Ford's speech pardoning Richard Nixon and the relationship between moral and legal themes. The speech failed because Ford did not effectively combine these themes into a single compatible perspective from which his pardon became the appropriate response to the situation. (JMF)
Fibrosis-Related Gene Expression in Single Ventricle Heart Disease.
Nakano, Stephanie J; Siomos, Austine K; Garcia, Anastacia M; Nguyen, Hieu; SooHoo, Megan; Galambos, Csaba; Nunley, Karin; Stauffer, Brian L; Sucharov, Carmen C; Miyamoto, Shelley D
2017-12-01
To evaluate fibrosis and fibrosis-related gene expression in the myocardium of pediatric subjects with single ventricle with right ventricular failure. Real-time quantitative polymerase chain reaction was performed on explanted right ventricular myocardium of pediatric subjects with single ventricle disease and controls with nonfailing heart disease. Subjects were divided into 3 groups: single ventricle failing (right ventricular failure before or after stage I palliation), single ventricle nonfailing (infants listed for primary transplantation with normal right ventricular function), and stage III (Fontan or right ventricular failure after stage III). To evaluate subjects of similar age and right ventricular volume loading, single ventricle disease with failure was compared with single ventricle without failure and stage III was compared with nonfailing right ventricular disease. Histologic fibrosis was assessed in all hearts. Mann-Whitney tests were performed to identify differences in gene expression. Collagen (Col1α, Col3) expression is decreased in single ventricle congenital heart disease with failure compared with nonfailing single ventricle congenital heart disease (P = .019 and P = .035, respectively), and is equivalent in stage III compared with nonfailing right ventricular heart disease. Tissue inhibitors of metalloproteinase (TIMP-1, TIMP-3, and TIMP-4) are downregulated in stage III compared with nonfailing right ventricular heart disease (P = .0047, P = .013 and P = .013, respectively). Matrix metalloproteinases (MMP-2, MMP-9) are similar between nonfailing single ventricular heart disease and failing single ventricular heart disease, and between stage III heart disease and nonfailing right ventricular heart disease. There is no difference in the prevalence of right ventricular fibrosis by histology in subjects with single ventricular failure heart disease with right ventricular failure (18%) compared with those with normal right ventricular function (38%). Fibrosis is not a primary contributor to right ventricular failure in infants and young children with single ventricular heart disease. Additional studies are required to understand whether antifibrotic therapies are beneficial in this population. Copyright © 2017 Elsevier Inc. All rights reserved.
Single Event Effects (SEE) for Power Metal-Oxide-Semiconductor Field-Effect Transistors (MOSFETs)
NASA Technical Reports Server (NTRS)
Lauenstein, Jean-Marie
2011-01-01
Single-event gate rupture (SEGR) continues to be a key failure mode in power MOSFETs. (1) SEGR is complex, making rate prediction difficult SEGR mechanism has two main components: (1) Oxide damage-- Reduces field required for rupture (2) Epilayer response -- Creates transient high field across the oxide.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Daniel, Isaac M.
To facilitate and accelerate the process of introducing, evaluating and adopting of new material systems, it is important to develop/establish comprehensive and effective procedures of characterization, modeling and failure prediction of structural laminates based on the properties of the constituent materials, e. g., fibers, matrix, and the single ply or lamina. A new failure theory, the Northwestern (NU-Daniel) theory, has been proposed for predicting lamina yielding and failure under multi-axial states of stress including strain rate effects. It is primarily applicable to matrix-dominated interfiber/interlaminar failures. It is based on micromechanical failure mechanisms but is expressed in terms of easily measuredmore » macroscopic lamina stiffness and strength properties. It is presented in the form of a master failure envelope incorporating strain rate effects. The theory was further adapted and extended to the prediction of in situ first ply yielding and failure (FPY and FPF) and progressive failure of multi-directional laminates under static and dynamic loadings. The significance of this theory is that it allows for rapid screening of new composite materials without very extensive testing and offers easily implemented design tools.« less
NASA Technical Reports Server (NTRS)
Behbehani, K.
1980-01-01
A new sensor/actuator failure analysis technique for turbofan jet engines was developed. Three phases of failure analysis, namely detection, isolation, and accommodation are considered. Failure detection and isolation techniques are developed by utilizing the concept of Generalized Likelihood Ratio (GLR) tests. These techniques are applicable to both time varying and time invariant systems. Three GLR detectors are developed for: (1) hard-over sensor failure; (2) hard-over actuator failure; and (3) brief disturbances in the actuators. The probability distribution of the GLR detectors and the detectability of sensor/actuator failures are established. Failure type is determined by the maximum of the GLR detectors. Failure accommodation is accomplished by extending the Multivariable Nyquest Array (MNA) control design techniques to nonsquare system designs. The performance and effectiveness of the failure analysis technique are studied by applying the technique to a turbofan jet engine, namely the Quiet Clean Short Haul Experimental Engine (QCSEE). Single and multiple sensor/actuator failures in the QCSEE are simulated and analyzed and the effects of model degradation are studied.
Microscopic observations during longitudinal compression loading of single pulp fibers
Irving B. Sachs
1986-01-01
Paperboard components (linerboard adn corrugating medium) fail in edgewise compression because of failure of single fibers, as well as fiber-to-fiber bonds. While fiber-to-fiber-bond failure has been studied extensively, little is known about the longitudinal compression failure of a single fiber. In this study, surface alterations on single loblolly pine kraft pulp...
Extended Testability Analysis Tool
NASA Technical Reports Server (NTRS)
Melcher, Kevin; Maul, William A.; Fulton, Christopher
2012-01-01
The Extended Testability Analysis (ETA) Tool is a software application that supports fault management (FM) by performing testability analyses on the fault propagation model of a given system. Fault management includes the prevention of faults through robust design margins and quality assurance methods, or the mitigation of system failures. Fault management requires an understanding of the system design and operation, potential failure mechanisms within the system, and the propagation of those potential failures through the system. The purpose of the ETA Tool software is to process the testability analysis results from a commercial software program called TEAMS Designer in order to provide a detailed set of diagnostic assessment reports. The ETA Tool is a command-line process with several user-selectable report output options. The ETA Tool also extends the COTS testability analysis and enables variation studies with sensor sensitivity impacts on system diagnostics and component isolation using a single testability output. The ETA Tool can also provide extended analyses from a single set of testability output files. The following analysis reports are available to the user: (1) the Detectability Report provides a breakdown of how each tested failure mode was detected, (2) the Test Utilization Report identifies all the failure modes that each test detects, (3) the Failure Mode Isolation Report demonstrates the system s ability to discriminate between failure modes, (4) the Component Isolation Report demonstrates the system s ability to discriminate between failure modes relative to the components containing the failure modes, (5) the Sensor Sensor Sensitivity Analysis Report shows the diagnostic impact due to loss of sensor information, and (6) the Effect Mapping Report identifies failure modes that result in specified system-level effects.
Effects of poverty on academic failure and delinquency in boys: a change and process model approach.
Pagani, L; Boulerice, B; Vitaro, F; Tremblay, R E
1999-11-01
Using data from the Montreal Longitudinal-Experimental Study, we examined the impact of poverty (and its correlate, family configuration status) on academic placement and self-reported delinquency in boys at age 16. We then investigated whether the relation between family economic hardship and antisocial behaviour is direct or indirect by considering the value of parenting practices and academic failure as process variables in the model. Data included official records, and parent, teacher, and self-reports. The temporal intensity of poverty was classified into five categories: never-poor; always-poor; poor-earlier; poor-later; and transitory-poverty. Family configuration status was classified by both temporal characteristics and number of marital transitions: intact-family; short-term-single; long-term-single; short-term-remarried; long-term-remarried; and multiple-marital-transitions. Results revealed that when maternal education and early childhood behaviour were controlled, poverty had an effect on both academic failure and extreme delinquency. This effect was independent of family configuration status. Although they both significantly predicted extreme delinquency on their own, academic failure and parental supervision did not mediate the relationship between poverty and delinquency. Divorce increased the risk of theft and fighting at age 16, regardless of financial hardship. Parental supervision only helped explain the effects of divorce on boys' fighting.
Electromigration resistance in a short three-contact interconnect tree
NASA Astrophysics Data System (ADS)
Chang, C. W.; Choi, Z.-S.; Thompson, C. V.; Gan, C. L.; Pey, K. L.; Choi, W. K.; Hwang, N.
2006-05-01
Electromigration has been characterized in via-terminated interconnect lines with additional vias in the middle, creating two adjacent segments that can be stressed independently. The mortality of a segment was found to depend on the direction and magnitude of the current in the adjacent segment, confirming that there is not a fixed value of the product of the current density and segment length, jL, that defines immortality in individual segments that are part of a multisegment interconnect tree. Instead, it is found that the probability of failure of a multisegment tree increases with the increasing value of an effective jL product defined in earlier work. However, contrary to expectations, the failures were still observed when (jL)eff was less than the critical jL product for which lines were found to be immortal in single-segment test structures. It is argued that this is due to reservoir effects associated with unstressed segments or due to liner failure at the central via. Multisegment test structures are therefore shown to reveal more types of failure mechanisms and mortality conditions that are not found in tests with single-segment structures.
Yield and failure criteria for composite materials under static and dynamic loading
Daniel, Isaac M.
2015-12-23
To facilitate and accelerate the process of introducing, evaluating and adopting of new material systems, it is important to develop/establish comprehensive and effective procedures of characterization, modeling and failure prediction of structural laminates based on the properties of the constituent materials, e. g., fibers, matrix, and the single ply or lamina. A new failure theory, the Northwestern (NU-Daniel) theory, has been proposed for predicting lamina yielding and failure under multi-axial states of stress including strain rate effects. It is primarily applicable to matrix-dominated interfiber/interlaminar failures. It is based on micromechanical failure mechanisms but is expressed in terms of easily measuredmore » macroscopic lamina stiffness and strength properties. It is presented in the form of a master failure envelope incorporating strain rate effects. The theory was further adapted and extended to the prediction of in situ first ply yielding and failure (FPY and FPF) and progressive failure of multi-directional laminates under static and dynamic loadings. The significance of this theory is that it allows for rapid screening of new composite materials without very extensive testing and offers easily implemented design tools.« less
14 CFR 25.629 - Aeroelastic stability requirements.
Code of Federal Regulations, 2012 CFR
2012-01-01
... weights are used, their effectiveness and strength, including supporting structure, must be substantiated... of any single element of the structure supporting any engine, independently mounted propeller shaft... dynamic forces, any single failure of the engine structure that would reduce the rigidity of the...
14 CFR 25.629 - Aeroelastic stability requirements.
Code of Federal Regulations, 2014 CFR
2014-01-01
... weights are used, their effectiveness and strength, including supporting structure, must be substantiated... of any single element of the structure supporting any engine, independently mounted propeller shaft... dynamic forces, any single failure of the engine structure that would reduce the rigidity of the...
14 CFR 25.629 - Aeroelastic stability requirements.
Code of Federal Regulations, 2011 CFR
2011-01-01
... weights are used, their effectiveness and strength, including supporting structure, must be substantiated... of any single element of the structure supporting any engine, independently mounted propeller shaft... dynamic forces, any single failure of the engine structure that would reduce the rigidity of the...
14 CFR 25.629 - Aeroelastic stability requirements.
Code of Federal Regulations, 2013 CFR
2013-01-01
... weights are used, their effectiveness and strength, including supporting structure, must be substantiated... of any single element of the structure supporting any engine, independently mounted propeller shaft... dynamic forces, any single failure of the engine structure that would reduce the rigidity of the...
Edwards, Steven J; Karner, Charlotta; Trevor, Nicola; Wakefield, Victoria; Salih, Fatima
2015-08-01
Bradycardia [resting heart rate below 60 beats per minute (b.p.m.)] can be caused by conditions affecting the natural pacemakers of the heart, such as sick sinus syndrome (SSS) and atrioventricular (AV) blocks. People suffering from bradycardia may present with palpitations, exercise intolerance and fainting. The only effective treatment for patients suffering from symptomatic bradycardia is implantation of a permanent pacemaker. To appraise the clinical effectiveness and cost-effectiveness of dual-chamber pacemakers compared with single-chamber atrial pacemakers for treating symptomatic bradycardia in people with SSS and no evidence of AV block. All databases (MEDLINE, EMBASE, Cochrane Central Register of Controlled Trials, Health Technology Assessment database, NHS Economic Evaluations Database) were searched from inception to June 2014. A systematic review of the clinical and economic literature was carried out in accordance with the general principles published by the Centre for Reviews and Dissemination. Randomised controlled trials (RCTs) evaluating dual-chamber and single-chamber atrial pacemakers and economic evaluations were included. Pairwise meta-analysis was carried out. A de novo economic model was developed. Of 493 references, six RCTs were included in the review. The results were predominantly influenced by the largest trial DANPACE. Dual-chamber pacing was associated with a statistically significant reduction in reoperation [odds ratio (OR) 0.48, 95% confidence interval (CI) 0.36 to 0.63] compared with single-chamber atrial pacing. The difference is primarily because of the development of AV block requiring upgrade to a dual-chamber device. The risk of paroxysmal atrial fibrillation was also reduced with dual-chamber pacing compared with single-chamber atrial pacing (OR 0.75, 95% CI 0.59 to 0.96). No statistically significant difference was found between the pacing modes for mortality, heart failure, stroke, chronic atrial fibrillation or quality of life. However, the risk of developing heart failure may vary with age and device. The de novo economic model shows that dual-chamber pacemakers are more expensive and more effective than single-chamber atrial devices, resulting in a base-case incremental cost-effectiveness ratio (ICER) of £6506. The ICER remains below £20,000 in probabilistic sensitivity analysis, structural sensitivity analysis and most scenario analyses and one-way sensitivity analyses. The risk of heart failure may have an impact on the decision to use dual-chamber or single-chamber atrial pacemakers. Results from an analysis based on age (> 75 years or ≤ 75 years) and risk of heart failure indicate that dual-chamber pacemakers dominate single-chamber atrial pacemakers (i.e. are less expensive and more effective) in older patients, whereas dual-chamber pacemakers are dominated by (i.e. more expensive and less effective) single-chamber atrial pacemakers in younger patients. However, these results are based on a subgroup analysis and should be treated with caution. In patients with SSS without evidence of impaired AV conduction, dual-chamber pacemakers appear to be cost-effective compared with single-chamber atrial pacemakers. The risk of developing a complete AV block and the lack of tools to identify patients at high risk of developing the condition argue for the implantation of a dual-chamber pacemaker programmed to minimise unnecessary ventricular pacing. However, considerations have to be made around the risk of developing heart failure, which may depend on age and device. This study is registered as PROSPERO CRD42013006708. The National Institute for Health Research Health Technology Assessment programme.
A bivariate model for analyzing recurrent multi-type automobile failures
NASA Astrophysics Data System (ADS)
Sunethra, A. A.; Sooriyarachchi, M. R.
2017-09-01
The failure mechanism in an automobile can be defined as a system of multi-type recurrent failures where failures can occur due to various multi-type failure modes and these failures are repetitive such that more than one failure can occur from each failure mode. In analysing such automobile failures, both the time and type of the failure serve as response variables. However, these two response variables are highly correlated with each other since the timing of failures has an association with the mode of the failure. When there are more than one correlated response variables, the fitting of a multivariate model is more preferable than separate univariate models. Therefore, a bivariate model of time and type of failure becomes appealing for such automobile failure data. When there are multiple failure observations pertaining to a single automobile, such data cannot be treated as independent data because failure instances of a single automobile are correlated with each other while failures among different automobiles can be treated as independent. Therefore, this study proposes a bivariate model consisting time and type of failure as responses adjusted for correlated data. The proposed model was formulated following the approaches of shared parameter models and random effects models for joining the responses and for representing the correlated data respectively. The proposed model is applied to a sample of automobile failures with three types of failure modes and up to five failure recurrences. The parametric distributions that were suitable for the two responses of time to failure and type of failure were Weibull distribution and multinomial distribution respectively. The proposed bivariate model was programmed in SAS Procedure Proc NLMIXED by user programming appropriate likelihood functions. The performance of the bivariate model was compared with separate univariate models fitted for the two responses and it was identified that better performance is secured by the bivariate model. The proposed model can be used to determine the time and type of failure that would occur in the automobiles considered here.
Effect of Crystal Orientation on Analysis of Single-Crystal, Nickel-Based Turbine Blade Superalloys
NASA Technical Reports Server (NTRS)
Swanson, G. R.; Arakere, N. K.
2000-01-01
High-cycle fatigue-induced failures in turbine and turbopump blades is a pervasive problem. Single-crystal nickel turbine blades are used because of their superior creep, stress rupture, melt resistance, and thermomechanical fatigue capabilities. Single-crystal materials have highly orthotropic properties making the position of the crystal lattice relative to the part geometry a significant and complicating factor. A fatigue failure criterion based on the maximum shear stress amplitude on the 24 octahedral and 6 cube slip systems is presented for single-crystal nickel superalloys (FCC crystal). This criterion greatly reduces the scatter in uniaxial fatigue data for PWA 1493 at 1,200 F in air. Additionally, single-crystal turbine blades used in the Space Shuttle main engine high pressure fuel turbopump/alternate turbopump are modeled using a three-dimensional finite element (FE) model. This model accounts for material orthotrophy and crystal orientation. Fatigue life of the blade tip is computed using FE stress results and the failure criterion that was developed. Stress analysis results in the blade attachment region are also presented. Results demonstrate that control of crystallographic orientation has the potential to significantly increase a component's resistance to fatigue crack growth without adding additional weight or cost.
Is psychology suffering from a replication crisis? What does "failure to replicate" really mean?
Maxwell, Scott E; Lau, Michael Y; Howard, George S
2015-09-01
Psychology has recently been viewed as facing a replication crisis because efforts to replicate past study findings frequently do not show the same result. Often, the first study showed a statistically significant result but the replication does not. Questions then arise about whether the first study results were false positives, and whether the replication study correctly indicates that there is truly no effect after all. This article suggests these so-called failures to replicate may not be failures at all, but rather are the result of low statistical power in single replication studies, and the result of failure to appreciate the need for multiple replications in order to have enough power to identify true effects. We provide examples of these power problems and suggest some solutions using Bayesian statistics and meta-analysis. Although the need for multiple replication studies may frustrate those who would prefer quick answers to psychology's alleged crisis, the large sample sizes typically needed to provide firm evidence will almost always require concerted efforts from multiple investigators. As a result, it remains to be seen how many of the recently claimed failures to replicate will be supported or instead may turn out to be artifacts of inadequate sample sizes and single study replications. (PsycINFO Database Record (c) 2015 APA, all rights reserved).
Rocket engine diagnostics using qualitative modeling techniques
NASA Technical Reports Server (NTRS)
Binder, Michael; Maul, William; Meyer, Claudia; Sovie, Amy
1992-01-01
Researchers at NASA Lewis Research Center are presently developing qualitative modeling techniques for automated rocket engine diagnostics. A qualitative model of a turbopump interpropellant seal system has been created. The qualitative model describes the effects of seal failures on the system steady-state behavior. This model is able to diagnose the failure of particular seals in the system based on anomalous temperature and pressure values. The anomalous values input to the qualitative model are generated using numerical simulations. Diagnostic test cases include both single and multiple seal failures.
Rocket engine diagnostics using qualitative modeling techniques
NASA Technical Reports Server (NTRS)
Binder, Michael; Maul, William; Meyer, Claudia; Sovie, Amy
1992-01-01
Researchers at NASA Lewis Research Center are presently developing qualitative modeling techniques for automated rocket engine diagnostics. A qualitative model of a turbopump interpropellant seal system was created. The qualitative model describes the effects of seal failures on the system steady state behavior. This model is able to diagnose the failure of particular seals in the system based on anomalous temperature and pressure values. The anomalous values input to the qualitative model are generated using numerical simulations. Diagnostic test cases include both single and multiple seal failures.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schubert, L; Westerly, D; Vinogradskiy, Y
Purpose: Collisions between treatment equipment and patients are potentially catastrophic. Modern technology now commonly involves automated remote motion during imaging and treatment, yet a systematic assessment to identify and mitigate collision risks has yet to be performed. Failure modes and effects analysis (FMEA) is a method of risk assessment that has been increasingly used in healthcare, yet can be resource intensive. This work presents an efficient approach to FMEA to identify collision risks and implement practical interventions within a modern radiation therapy department. Methods: Potential collisions (e.g. failure modes) were assessed for all treatment and simulation rooms by teams consistingmore » of physicists, therapists, and radiation oncologists. Failure modes were grouped into classes according to similar characteristics. A single group meeting was held to identify implementable interventions for the highest priority classes of failure modes. Results: A total of 60 unique failure modes were identified by 6 different teams of physicists, therapists, and radiation oncologists. Failure modes were grouped into four main classes: specific patient setups, automated equipment motion, manual equipment motion, and actions in QA or service mode. Two of these classes, unusual patient setups and automated machine motion, were identified as being high priority in terms severity of consequence and addressability by interventions. The two highest risk classes consisted of 33 failure modes (55% of the total). In a single one hour group meeting, 6 interventions were identified. Those interventions addressed 100% of the high risk classes of failure modes (55% of all failure modes identified). Conclusion: A class-based approach to FMEA was developed to efficiently identify collision risks and implement interventions in a modern radiation oncology department. Failure modes and interventions will be listed, and a comparison of this approach against traditional FMEA methods will be presented.« less
NASA Astrophysics Data System (ADS)
White, Bradley W.; Tarver, Craig M.
2017-01-01
It has long been known that detonating single crystals of solid explosives have much larger failure diameters than those of heterogeneous charges of the same explosive pressed or cast to 98 - 99% theoretical maximum density (TMD). In 1957, Holland et al. demonstrated that PETN single crystals have failure diameters of about 8 mm, whereas heterogeneous PETN charges have failure diameters of less than 0.5 mm. Recently, Fedorov et al. quantitatively determined nanosecond time resolved detonation reaction zone profiles of single crystals of PETN and HMX by measuring the interface particle velocity histories of the detonating crystals and LiF windows using a PDV system. The measured reaction zone time durations for PETN and HMX single crystal detonations were approximately 100 and 260 nanoseconds, respectively. These experiments provided the necessary data to develop Ignition and Growth (I&G) reactive flow model parameters for the single crystal detonation reaction zones. Using these parameters, the calculated unconfined failure diameter of a PETN single crystal was 7.5 +/- 0.5 mm, close to the 8 mm experimental value. The calculated failure diameter of an unconfined HMX single crystal was 15 +/- 1 mm. The unconfined failure diameter of an HMX single crystal has not yet been determined precisely, but Fedorov et al. detonated 14 mm diameter crystals confined by detonating a HMX-based plastic bonded explosive (PBX) without initially overdriving the HMX crystals.
CRANS - CONFIGURABLE REAL-TIME ANALYSIS SYSTEM
NASA Technical Reports Server (NTRS)
Mccluney, K.
1994-01-01
In a real-time environment, the results of changes or failures in a complex, interconnected system need evaluation quickly. Tabulations showing the effects of changes and/or failures of a given item in the system are generally only useful for a single input, and only with regard to that item. Subsequent changes become harder to evaluate as combinations of failures produce a cascade effect. When confronted by multiple indicated failures in the system, it becomes necessary to determine a single cause. In this case, failure tables are not very helpful. CRANS, the Configurable Real-time ANalysis System, can interpret a logic tree, constructed by the user, describing a complex system and determine the effects of changes and failures in it. Items in the tree are related to each other by Boolean operators. The user is then able to change the state of these items (ON/OFF FAILED/UNFAILED). The program then evaluates the logic tree based on these changes and determines any resultant changes to other items in the tree. CRANS can also search for a common cause for multiple item failures, and allow the user to explore the logic tree from within the program. A "help" mode and a reference check provide the user with a means of exploring an item's underlying logic from within the program. A commonality check determines single point failures for an item or group of items. Output is in the form of a user-defined matrix or matrices of colored boxes, each box representing an item or set of items from the logic tree. Input is via mouse selection of the matrix boxes, using the mouse buttons to toggle the state of the item. CRANS is written in C-language and requires the MIT X Window System, Version 11 Revision 4 or Revision 5. It requires 78K of RAM for execution and a three button mouse. It has been successfully implemented on Sun4 workstations running SunOS, HP9000 workstations running HP-UX, and DECstations running ULTRIX. No executable is provided on the distribution medium; however, a sample makefile is included. Sample input files are also included. The standard distribution medium is a .25 inch streaming magnetic tape cartridge (Sun QIC-24) in UNIX tar format. Alternate distribution media and formats are available upon request. This program was developed in 1992.
(n, N) type maintenance policy for multi-component systems with failure interactions
NASA Astrophysics Data System (ADS)
Zhang, Zhuoqi; Wu, Su; Li, Binfeng; Lee, Seungchul
2015-04-01
This paper studies maintenance policies for multi-component systems in which failure interactions and opportunistic maintenance (OM) involve. This maintenance problem can be formulated as a Markov decision process (MDP). However, since an action set and state space in MDP exponentially expand as the number of components increase, traditional approaches are computationally intractable. To deal with curse of dimensionality, we decompose such a multi-component system into mutually influential single-component systems. Each single-component system is formulated as an MDP with the objective of minimising its long-run average maintenance cost. Under some reasonable assumptions, we prove the existence of the optimal (n, N) type policy for a single-component system. An algorithm to obtain the optimal (n, N) type policy is also proposed. Based on the proposed algorithm, we develop an iterative approximation algorithm to obtain an acceptable maintenance policy for a multi-component system. Numerical examples find that failure interactions and OM pose significant effects on a maintenance policy.
NASA Astrophysics Data System (ADS)
McCrea, Terry
The Shuttle Processing Contract (SPC) workforce consists of Lockheed Space Operations Co. as prime contractor, with Grumman, Thiokol Corporation, and Johnson Controls World Services as subcontractors. During the design phase, reliability engineering is instrumental in influencing the development of systems that meet the Shuttle fail-safe program requirements. Reliability engineers accomplish this objective by performing FMEA (failure modes and effects analysis) to identify potential single failure points. When technology, time, or resources do not permit a redesign to eliminate a single failure point, the single failure point information is formatted into a change request and presented to senior management of SPC and NASA for risk acceptance. In parallel with the FMEA, safety engineering conducts a hazard analysis to assure that potential hazards to personnel are assessed. The combined effort (FMEA and hazard analysis) is published as a system assurance analysis. Special ground rules and techniques are developed to perform and present the analysis. The reliability program at KSC is vigorously pursued, and has been extremely successful. The ground support equipment and facilities used to launch and land the Space Shuttle maintain an excellent reliability record.
Model-OA wind turbine generator - Failure modes and effects analysis
NASA Technical Reports Server (NTRS)
Klein, William E.; Lali, Vincent R.
1990-01-01
The results failure modes and effects analysis (FMEA) conducted for wind-turbine generators are presented. The FMEA was performed for the functional modes of each system, subsystem, or component. The single-point failures were eliminated for most of the systems. The blade system was the only exception. The qualitative probability of a blade separating was estimated at level D-remote. Many changes were made to the hardware as a result of this analysis. The most significant change was the addition of the safety system. Operational experience and need to improve machine availability have resulted in subsequent changes to the various systems, which are also reflected in this FMEA.
How securely is the testicular artery occluded in the spermatic cord by using a ligature?
Rijkenhuizen, A B M; Sommerauer, S; Fasching, M; Velde, K; Peham, C
2013-09-01
There are no studies on the ideal ligature technique for the spermatic cord. To compare the maximal resistance pressure in the testicular artery and the maximal tensile forces to produce failure of 2 different ligature techniques used for ligation of the equine spermatic cord. The capabilities of 2 types of ligatures, single knot loop and double knot loop, were assessed using a pressure-resistance test in testicular arteries and with an in vitro mechanical evaluation of the tensile strength by single cycle-to-failure testing. In the pressure-resistance test, the mean ± s.d. peak force at failure of the single knot loop was 354.4 ± 91.7 mmHg and for the double knot loop 303.2 ± 62.0 mmHg. There was no significant difference between the maximal load to failure of the single knot loop and double knot loop technique. The pressure needed for rupture was significantly higher (P = 0.001) than for leakage. The maximal tensile force at failure of the single knot loop was significantly higher than the double knot loop (P = 0.028). There was no significant difference in load elongation properties to failure between the single knot loop and double knot loop. Although no significant differences were obtained in the pressure-resistance test, the single knot loop sustained significantly greater load to failure than the double knot loop in single cycle-to-failure testing. Based on these findings, it would appear that the performance of the single knot loop should be superior to the double knot loop. Both ligature techniques are able to withstand the normal physiological intravascular pressure. The single knot loop has the greater breaking strength of the 2 ligatures tested and is less time consuming to perform and may therefore have advantages during equine castration. © 2012 EVJ Ltd.
Bonin, Lucie; Pedreiro, Cécile; Moret, Stéphanie; Chene, Gautier; Gaucherand, Pascal; Lamblin, Géry
2017-01-01
We sought to evaluate the global success rate of intramuscular methotrexate for the treatment of ectopic pregnancy, identify factors predictive of treatment success or failure, and study methotrexate tolerability in a large patient cohort. For this single-center retrospective observational study, we retrieved the records of all women who had a clinically or echographically confirmed ectopic pregnancy with a Fernandez score <13 and who were treated according to a 1mg/kg intramuscular single-dose methotrexate protocol. Medical treatment failure was defined by an obligation to proceed to laparoscopy. Needing a second injection was not considered to be medical treatment failure. Between February 2008 and November 2013 (69 months), 400 women received methotrexate for ectopic pregnancy. The medical treatment protocol was effective for 314 patients, i.e., an overall success rate of 78.5%. A single methotrexate dose was sufficient for 63.5% of the women and a second dose was successful for 73.2% of the remaining women. The medical treatment success rate fell as initial hCG levels climbed. The main factors associated with methotrexate failure included day (D) 0, D4 and D7 hCG levels, pretherapeutic blood progesterone, hematosalpinx at D0 and pain at D7. Early favorable kinetics of hCG levels was predictive of success. Methotrexate treatment was successful in 90% of women who had D0 hCG <1000IU/l. Methotrexate tolerability was good, with only 9% of the women reporting non-severe adverse effects. The fertility rate with delivery after medical treatment for ectopic pregnancy was 80.7%. In this study, we showed that an initial hCG value <1000IU/l and favorable early HCG kinetics were predictive factors for the successful medical treatment of ectopic pregnancy by methotrexate, and hematosalpinx and pretherapeutic blood progesterone >5ng/ml at diagnosis were predictive of its failure. We also confirmed good tolerability for single-dose methotrexate protocols. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Time-dependent earthquake probabilities
Gomberg, J.; Belardinelli, M.E.; Cocco, M.; Reasenberg, P.
2005-01-01
We have attempted to provide a careful examination of a class of approaches for estimating the conditional probability of failure of a single large earthquake, particularly approaches that account for static stress perturbations to tectonic loading as in the approaches of Stein et al. (1997) and Hardebeck (2004). We have loading as in the framework based on a simple, generalized rate change formulation and applied it to these two approaches to show how they relate to one another. We also have attempted to show the connection between models of seismicity rate changes applied to (1) populations of independent faults as in background and aftershock seismicity and (2) changes in estimates of the conditional probability of failures of different members of a the notion of failure rate corresponds to successive failures of different members of a population of faults. The latter application requires specification of some probability distribution (density function of PDF) that describes some population of potential recurrence times. This PDF may reflect our imperfect knowledge of when past earthquakes have occurred on a fault (epistemic uncertainty), the true natural variability in failure times, or some combination of both. We suggest two end-member conceptual single-fault models that may explain natural variability in recurrence times and suggest how they might be distinguished observationally. When viewed deterministically, these single-fault patch models differ significantly in their physical attributes, and when faults are immature, they differ in their responses to stress perturbations. Estimates of conditional failure probabilities effectively integrate over a range of possible deterministic fault models, usually with ranges that correspond to mature faults. Thus conditional failure probability estimates usually should not differ significantly for these models. Copyright 2005 by the American Geophysical Union.
Reed, Shelby D; Neilson, Matthew P; Gardner, Matthew; Li, Yanhong; Briggs, Andrew H; Polsky, Daniel E; Graham, Felicia L; Bowers, Margaret T; Paul, Sara C; Granger, Bradi B; Schulman, Kevin A; Whellan, David J; Riegel, Barbara; Levy, Wayne C
2015-11-01
Heart failure disease management programs can influence medical resource use and quality-adjusted survival. Because projecting long-term costs and survival is challenging, a consistent and valid approach to extrapolating short-term outcomes would be valuable. We developed the Tools for Economic Analysis of Patient Management Interventions in Heart Failure Cost-Effectiveness Model, a Web-based simulation tool designed to integrate data on demographic, clinical, and laboratory characteristics; use of evidence-based medications; and costs to generate predicted outcomes. Survival projections are based on a modified Seattle Heart Failure Model. Projections of resource use and quality of life are modeled using relationships with time-varying Seattle Heart Failure Model scores. The model can be used to evaluate parallel-group and single-cohort study designs and hypothetical programs. Simulations consist of 10,000 pairs of virtual cohorts used to generate estimates of resource use, costs, survival, and incremental cost-effectiveness ratios from user inputs. The model demonstrated acceptable internal and external validity in replicating resource use, costs, and survival estimates from 3 clinical trials. Simulations to evaluate the cost-effectiveness of heart failure disease management programs across 3 scenarios demonstrate how the model can be used to design a program in which short-term improvements in functioning and use of evidence-based treatments are sufficient to demonstrate good long-term value to the health care system. The Tools for Economic Analysis of Patient Management Interventions in Heart Failure Cost-Effectiveness Model provides researchers and providers with a tool for conducting long-term cost-effectiveness analyses of disease management programs in heart failure. Copyright © 2015 Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Scheick, Leif
2014-01-01
Recent testing of the EPC1000 series eGaN FETs has shown sensitivity to Single Event Effects (SEE) that are destructive. These effects are most likely the failure of the very thin gate structure in HEMT architecture. EPC has recently changed the doping of the substrate to improve the performance and the SEE response. This testing compares the SEE response of both devices.
Clinical evaluation of rosoxacin for the treatment of chancroid.
Haase, D A; Ndinya-Achola, J O; Nash, R A; D'Costa, L J; Hazlett, D; Lubwama, S; Nsanze, H; Ronald, A R
1986-01-01
One hundred seven men with Haemophilus ducreyi-positive chancroid were assigned to receive 300 mg of rosoxacin as a single dose or 150 mg twice daily for 3 days. Ulcers and buboes were followed clinically and bacteriologically for 1 month. Of 40 evaluable males on the 3-day regimen, 38 (95%) were cured, while only 14 of 23 (61%) males on the single-dose regimen were cured; this regimen was discontinued. There was one ulcer relapse at day 21 in both groups; the one relapse in the single-dose group had a persistent culture-positive bubo. Eight of nine (89%) buboes followed to the endpoint on the 3-day rosoxacin regimen were cured, versus three of six (50%) on the single-dose regimen. Adverse effects were mainly related to the central nervous system but were minor and did not require intervention. None of the treatment failures was due to organisms resistant to rosoxacin, and failure of the single-dose regimen presumably was related to duration of tissue levels rather than to drug resistance. Administration of 150 mg of rosoxacin twice daily for 3 days is an effective regimen for the therapy of chancroid and is a reasonable alternative to other short-course regimens. PMID:3489439
Single-row versus double-row repair of the distal Achilles tendon: a biomechanical comparison.
Pilson, Holly; Brown, Philip; Stitzel, Joel; Scott, Aaron
2012-01-01
Surgery for recalcitrant insertional Achilles tendinopathy often consists of partial or total release of the insertion site, debridement of the diseased portion of the tendon, calcaneal ostectomy, and reattachment of the Achilles to the calcaneus. Although single-row and double-row techniques exist for repair of the detached Achilles tendon, biomechanical data are lacking to support one technique over the other. Based on data extrapolated from the study of rotator cuff repairs, we hypothesized that a double-row construct would provide superior fixation strength over a single-row repair. Eighteen human cadaveric Achilles tendons (9 matched pairs) with attached calcanei were repaired with single-row or double-row techniques. Specimens were mounted in a servohydraulic materials testing machine, subjected to a preconditioning cycle, and loaded to failure. Failure was defined as suture breakage or pullout, midsubstance tendon rupture, or anchor pullout. Among the failures were 12 suture failures, 5 proximal-row anchor failures, and 1 distal-row anchor failure. No midsubstance tendon ruptures or testing apparatus failures were observed. There were no statistically significant differences in the peak load to failure between the single-row and double-row repairs (p = .46). Similarly, no significant differences were observed with regards to mean energy expenditure to failure (p = .069). The present study demonstrated no biomechanical advantages of the double-row repair over a single-row repair. Despite the lack of a clear biomechanical advantage, there may exist clinical advantages of a double-row repair, such as reduction in knot prominence and restoration of the Achilles footprint. Copyright © 2012 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.
Baums, M H; Buchhorn, G H; Gilbert, F; Spahn, G; Schultz, W; Klinger, H-M
2010-09-01
This experimental study aimed to compare the load-to-failure rate and stiffness of single- versus double-row suture techniques for repairing rotator cuff lesions using two different suture materials. Additionally, the mode of failure of each repair was evaluated. In 32 sheep shoulders, a standardized tear of the infraspinatus tendon was created. Then, n = 8 specimen were randomized to four repair methods: (1) Double-row Anchor Ethibond coupled with polyester sutures, USP No. 2; (2) Double-Row Anchor HiFi with polyblend polyethylene sutures, USP No. 2; (3) Single-Row Anchor Ethibond coupled with braided polyester sutures, USP No. 2; and (4) Single-Row Anchor HiFi with braided polyblend polyethylene sutures, USP No. 2. Arthroscopic Mason-Allen stitches were placed (single-row) and combined with medial horizontal mattress stitches (double-row). All specimens were loaded to failure at a constant displacement rate on a material testing machine. Group 4 showed lowest load-to-failure result with 155.7 +/- 31.1 N compared to group 1 (293.4 +/- 16.1 N) and group 2 (397.7 +/- 7.4 N) (P < 0.001). Stiffness was highest in group 2 (162 +/- 7.3 N/mm) and lowest in group 4 (84.4 +/- 19.9 mm) (P < 0.001). In group 4, the main cause of failure was due to the suture cutting through the tendon (n = 6), a failure case observed in only n = 1 specimen in group 2 (P < 0.001). A double-row technique combined with arthroscopic Mason-Allen/horizontal mattress stitches provides high initial failure strength and may minimize the risk of the polyethylene sutures cutting through the tendon in rotator cuff repair when a single load force is used.
Meso-modeling of Carbon Fiber Composite for Crash Safety Analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lin, Shih-Po; Chen, Yijung; Zeng, Danielle
2017-04-06
In the conventional approach, the material properties for crash safety simulations are typically obtained from standard coupon tests, where the test results only provide single layer material properties used in crash simulations. However, the lay-up effects for the failure behaviors of the real structure were not considered in numerical simulations. Hence, there was discrepancy between the crash simulations and experimental tests. Consequently, an intermediate stage is required for accurate predictions. Some component tests are required to correlate the material models in the intermediate stage. In this paper, a Mazda Tube under high-impact velocity is chosen as an example for themore » crash safety analysis. The tube consists of 24 layers of uni-directional (UD) carbon fiber composite materials, in which 4 layers are perpendicular to, while the other layers are parallel to the impact direction. An LS-DYNA meso-model was constructed with orthotropic material models counting for the single-layer material behaviors. Between layers, a node-based tie-break contact was used for modeling the delamination of the composite material. Since fiber directions are not single-oriented, the lay-up effects could be an important effect. From the first numerical trial, premature material failure occurred due to the use of material parameters obtained directly from the coupon tests. Some parametric studies were conducted to identify the cause of the numerical instability. The finding is that the material failure strength used in the numerical model needs to be enlarged to stabilize the numerical model. Some hypothesis was made to provide the foundation for enlarging the failure strength and the corresponding experiments will be conducted to validate the hypothesis.« less
High reliability and high performance of 9xx-nm single emitter laser diodes
NASA Astrophysics Data System (ADS)
Bao, L.; Leisher, P.; Wang, J.; Devito, M.; Xu, D.; Grimshaw, M.; Dong, W.; Guan, X.; Zhang, S.; Bai, C.; Bai, J. G.; Wise, D.; Martinsen, R.
2011-03-01
Improved performance and reliability of 9xx nm single emitter laser diodes are presented. To date, over 15,000 hours of accelerated multi-cell lifetest reliability data has been collected, with drive currents from 14A to 18A and junction temperatures ranging from 60°C to 110°C. Out of 208 devices, 14 failures have been observed so far. Using established accelerated lifetest analysis techniques, the effects of temperature and power acceleration are assessed. The Mean Time to Failure (MTTF) is determined to be >30 years, for use condition 10W and junction temperature 353K (80°C), with 90% statistical confidence.
Compression Fracture of CFRP Laminates Containing Stress Intensifications.
Leopold, Christian; Schütt, Martin; Liebig, Wilfried V; Philipkowski, Timo; Kürten, Jonas; Schulte, Karl; Fiedler, Bodo
2017-09-05
For brittle fracture behaviour of carbon fibre reinforced plastics (CFRP) under compression, several approaches exist, which describe different mechanisms during failure, especially at stress intensifications. The failure process is not only initiated by the buckling fibres, but a shear driven fibre compressive failure beneficiaries or initiates the formation of fibres into a kink-band. Starting from this kink-band further damage can be detected, which leads to the final failure. The subject of this work is an experimental investigation on the influence of ply thickness and stacking sequence in quasi-isotropic CFRP laminates containing stress intensifications under compression loading. Different effects that influence the compression failure and the role the stacking sequence has on damage development and the resulting compressive strength are identified and discussed. The influence of stress intensifications is investigated in detail at a hole in open hole compression (OHC) tests. A proposed interrupted test approach allows identifying the mechanisms of damage initiation and propagation from the free edge of the hole by causing a distinct damage state and examine it at a precise instant of time during fracture process. Compression after impact (CAI) tests are executed in order to compare the OHC results to a different type of stress intensifications. Unnotched compression tests are carried out for comparison as a reference. With this approach, a more detailed description of the failure mechanisms during the sudden compression failure of CFRP is achieved. By microscopic examination of single plies from various specimens, the different effects that influence the compression failure are identified. First damage of fibres occurs always in 0°-ply. Fibre shear failure leads to local microbuckling and the formation and growth of a kink-band as final failure mechanisms. The formation of a kink-band and finally steady state kinking is shifted to higher compressive strains with decreasing ply thickness. Final failure mode in laminates with stress intensification depends on ply thickness. In thick or inner plies, damage initiates as shear failure and fibre buckling into the drilled hole. The kink-band orientation angle is changing with increasing strain. In outer or thin plies shear failure of single fibres is observed as first damage and the kink-band orientation angle is constant until final failure. Decreasing ply thickness increases the unnotched compressive strength. When stress intensifications are present, the position of the 0°-layer is critical for stability under compression and is thus more important than the ply thickness. Central 0°-layers show best results for OHC and CAI strength due to higher bending stiffness and better supporting effect of the adjacent layers.
Compression Fracture of CFRP Laminates Containing Stress Intensifications
Schütt, Martin; Philipkowski, Timo; Kürten, Jonas; Schulte, Karl
2017-01-01
For brittle fracture behaviour of carbon fibre reinforced plastics (CFRP) under compression, several approaches exist, which describe different mechanisms during failure, especially at stress intensifications. The failure process is not only initiated by the buckling fibres, but a shear driven fibre compressive failure beneficiaries or initiates the formation of fibres into a kink-band. Starting from this kink-band further damage can be detected, which leads to the final failure. The subject of this work is an experimental investigation on the influence of ply thickness and stacking sequence in quasi-isotropic CFRP laminates containing stress intensifications under compression loading. Different effects that influence the compression failure and the role the stacking sequence has on damage development and the resulting compressive strength are identified and discussed. The influence of stress intensifications is investigated in detail at a hole in open hole compression (OHC) tests. A proposed interrupted test approach allows identifying the mechanisms of damage initiation and propagation from the free edge of the hole by causing a distinct damage state and examine it at a precise instant of time during fracture process. Compression after impact (CAI) tests are executed in order to compare the OHC results to a different type of stress intensifications. Unnotched compression tests are carried out for comparison as a reference. With this approach, a more detailed description of the failure mechanisms during the sudden compression failure of CFRP is achieved. By microscopic examination of single plies from various specimens, the different effects that influence the compression failure are identified. First damage of fibres occurs always in 0°-ply. Fibre shear failure leads to local microbuckling and the formation and growth of a kink-band as final failure mechanisms. The formation of a kink-band and finally steady state kinking is shifted to higher compressive strains with decreasing ply thickness. Final failure mode in laminates with stress intensification depends on ply thickness. In thick or inner plies, damage initiates as shear failure and fibre buckling into the drilled hole. The kink-band orientation angle is changing with increasing strain. In outer or thin plies shear failure of single fibres is observed as first damage and the kink-band orientation angle is constant until final failure. Decreasing ply thickness increases the unnotched compressive strength. When stress intensifications are present, the position of the 0°-layer is critical for stability under compression and is thus more important than the ply thickness. Central 0°-layers show best results for OHC and CAI strength due to higher bending stiffness and better supporting effect of the adjacent layers. PMID:28872623
Failure propagation in multi-cell lithium ion batteries
Lamb, Joshua; Orendorff, Christopher J.; Steele, Leigh Anna M.; ...
2014-10-22
Traditionally, safety and impact of failure concerns of lithium ion batteries have dealt with the field failure of single cells. However, large and complex battery systems require the consideration of how a single cell failure will impact the system as a whole. Initial failure that leads to the thermal runaway of other cells within the system creates a much more serious condition than the failure of a single cell. This work examines the behavior of small modules of cylindrical and stacked pouch cells after thermal runaway is induced in a single cell through nail penetration trigger [1] within the module.more » Cylindrical cells are observed to be less prone to propagate, if failure propagates at all, owing to the limited contact between neighboring cells. However, the electrical connectivity is found to be impactful as the 10S1P cylindrical cell module did not show failure propagation through the module, while the 1S10P module had an energetic thermal runaway consuming the module minutes after the initiation failure trigger. Modules built using pouch cells conversely showed the impact of strong heat transfer between cells. In this case, a large surface area of the cells was in direct contact with its neighbors, allowing failure to propagate through the entire battery within 60-80 seconds for all configurations (parallel or series) tested. This work demonstrates the increased severity possible when a point failure impacts the surrounding battery system.« less
NASA Technical Reports Server (NTRS)
Mansur, M. Hossein; Schroeder, Jeffery A.
1988-01-01
A moving-base simulation was conducted to investigate a pilot's ability to recover from transients following single-axis hard-over failures of the flight-control system. The investigation was performed in conjunction with a host simulation that examined the influence of control modes on a single pilot's ability to perform various mission elements under high-workload conditions. The NASA Ames large-amplitude-motion Vertical Motion Simulator (VMS) was utilized, and the experimental variables were the failure axis, the severity of the failure, and the airspeed at which the failure occurred. Other factors, such as pilot workload and terrain and obstacle proximity at the time of failure, were kept as constant as possible within the framework of the host simulation task scenarios. No explicit failure warnings were presented to the pilot. Data from the experiment are shown, and pilot ratings are compared with the proposed handling-qualities requirements for military rotorcraft. Results indicate that the current proposed failure transient requirements may need revision.
Valve system incorporating single failure protection logic
Ryan, Rodger; Timmerman, Walter J. H.
1980-01-01
A valve system incorporating single failure protective logic. The system consists of a valve combination or composite valve which allows actuation or de-actuation of a device such as a hydraulic cylinder or other mechanism, integral with or separate from the valve assembly, by means of three independent input signals combined in a function commonly known as two-out-of-three logic. Using the input signals as independent and redundant actuation/de-actuation signals, a single signal failure, or failure of the corresponding valve or valve set, will neither prevent the desired action, nor cause the undesired action of the mechanism.
Malonza, I M; Tyndall, M W; Ndinya-Achola, J O; Maclean, I; Omar, S; MacDonald, K S; Perriens, J; Orle, K; Plummer, F A; Ronald, A R; Moses, S
1999-12-01
A randomized, double-blind, placebo-controlled clinical trial was conducted in Nairobi, Kenya, to compare single-dose ciprofloxacin with a 7-day course of erythromycin for the treatment of chancroid. In all, 208 men and 37 women presenting with genital ulcers clinically compatible with chancroid were enrolled. Ulcer etiology was determined using culture techniques for chancroid, serology for syphilis, and a multiplex polymerase chain reaction for chancroid, syphilis, and herpes simplex virus (HSV). Ulcer etiology was 31% unmixed chancroid, 23% unmixed syphilis, 16% unmixed HSV, 15% mixed etiology, and 15% unknown. For 111 participants with chancroid, cure rates were 92% with ciprofloxacin and 91% with erythromycin. For all study participants, the treatment failure rate was 15%, mostly related to ulcer etiologies of HSV infection or syphilis, and treatment failure was 3 times more frequent in human immunodeficiency virus-infected subjects than in others, mostly owing to HSV infection. Ciprofloxacin is an effective single-dose treatment for chancroid, but current recommendations for empiric therapy of genital ulcers may result in high treatment failure due to HSV infection.
Ye, Qing; Pan, Hao; Liu, Changhua
2015-01-01
This research proposes a novel framework of final drive simultaneous failure diagnosis containing feature extraction, training paired diagnostic models, generating decision threshold, and recognizing simultaneous failure modes. In feature extraction module, adopt wavelet package transform and fuzzy entropy to reduce noise interference and extract representative features of failure mode. Use single failure sample to construct probability classifiers based on paired sparse Bayesian extreme learning machine which is trained only by single failure modes and have high generalization and sparsity of sparse Bayesian learning approach. To generate optimal decision threshold which can convert probability output obtained from classifiers into final simultaneous failure modes, this research proposes using samples containing both single and simultaneous failure modes and Grid search method which is superior to traditional techniques in global optimization. Compared with other frequently used diagnostic approaches based on support vector machine and probability neural networks, experiment results based on F 1-measure value verify that the diagnostic accuracy and efficiency of the proposed framework which are crucial for simultaneous failure diagnosis are superior to the existing approach. PMID:25722717
Effects of Ion Atomic Number on Single-Event Gate Rupture (SEGR) Susceptibility of Power MOSFETs
NASA Technical Reports Server (NTRS)
Lauenstein, Jean-Marie; Goldsman, Neil; Liu, Sandra; Titus, Jeffrey L.; Ladbury, Raymond L.; Kim, Hak S.; Phan, Anthony M.; LaBel, Kenneth A.; Zafrani, Max; Sherman, Phillip
2012-01-01
The relative importance of heavy-ion interaction with the oxide, charge ionized in the epilayer, and charge ionized in the drain substrate, on the bias for SEGR failure in vertical power MOSFETs is experimentally investigated. The results indicate that both the charge ionized in the epilayer and the ion atomic number are important parameters of SEGR failure. Implications on SEGR hardness assurance are discussed.
23 CFR 668.107 - Federal share payable.
Code of Federal Regulations, 2012 CFR
2012-04-01
... natural disaster or catastrophic failure may amount to 100 percent of the costs thereof. (b) Total... those on Federal roads under 23 CFR part 668, subpart B), resulting from a single natural disaster or a single catastrophic failure, shall not exceed $100 million per disaster or catastrophic failure. The...
23 CFR 668.107 - Federal share payable.
Code of Federal Regulations, 2010 CFR
2010-04-01
... natural disaster or catastrophic failure may amount to 100 percent of the costs thereof. (b) Total... those on Federal roads under 23 CFR part 668, subpart B), resulting from a single natural disaster or a single catastrophic failure, shall not exceed $100 million per disaster or catastrophic failure. The...
23 CFR 668.107 - Federal share payable.
Code of Federal Regulations, 2014 CFR
2014-04-01
... natural disaster or catastrophic failure may amount to 100 percent of the costs thereof. (b) Total... those on Federal roads under 23 CFR part 668, subpart B), resulting from a single natural disaster or a single catastrophic failure, shall not exceed $100 million per disaster or catastrophic failure. The...
23 CFR 668.107 - Federal share payable.
Code of Federal Regulations, 2011 CFR
2011-04-01
... natural disaster or catastrophic failure may amount to 100 percent of the costs thereof. (b) Total... those on Federal roads under 23 CFR part 668, subpart B), resulting from a single natural disaster or a single catastrophic failure, shall not exceed $100 million per disaster or catastrophic failure. The...
23 CFR 668.107 - Federal share payable.
Code of Federal Regulations, 2013 CFR
2013-04-01
... natural disaster or catastrophic failure may amount to 100 percent of the costs thereof. (b) Total... those on Federal roads under 23 CFR part 668, subpart B), resulting from a single natural disaster or a single catastrophic failure, shall not exceed $100 million per disaster or catastrophic failure. The...
NASA Astrophysics Data System (ADS)
Ma, Limin; Zuo, Yong; Liu, Sihan; Guo, Fu; Wang, Xitao
2013-01-01
Currently, the main concerns of Pb-free solder joints are focusing on electromigration (EM) and thermomechanical fatigue (TMF) problems. Many models have been established to understand the failure mechanisms of the joint under such single test conditions. Based on the fact that almost all microelectronic devices serve in combination conditions of fluctuated temperature and electric current stressing, the coupling effects of EM and TMF on evolution of microstructure and resistance of solder joint had been investigated. The failure models of binary SnBi alloy and ternary SnAgCu (SAC) solder under the coupling stressing were divided into four and three different stages, respectively. The failure mechanisms were dominant by the relationship of phase segregation, polarity effect, phase coarsening, and the coefficient of thermal expansion mismatch. Cracks tend to form and propagate along the interface between intermetallic compound layers and solder matrix in SAC solder. However, grain boundary was considered as the nucleation sites for microcracks in SnBi solder. High current density alleviates the deterioration of solder at the beginning stage of coupling stressing through Joule heating effect. An abrupt jump of resistance could be observed before the failure of the joint. The failure molds were determined by interactions of EM behaviors and TMF damages.
Chin, Ki Jinn; Alakkad, Husni; Cubillos, Javier E
2013-08-08
Regional anaesthesia comprising axillary block of the brachial plexus is a common anaesthetic technique for distal upper limb surgery. This is an update of a review first published in 2006 and updated in 2011. To compare the relative effects (benefits and harms) of three injection techniques (single, double and multiple) of axillary block of the brachial plexus for distal upper extremity surgery. We considered these effects primarily in terms of anaesthetic effectiveness; the complication rate (neurological and vascular); and pain and discomfort caused by performance of the block. We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library), MEDLINE, EMBASE and reference lists of trials. We contacted trial authors. The date of the last search was March 2013 (updated from March 2011). We included randomized controlled trials that compared double with single-injection techniques, multiple with single-injection techniques, or multiple with double-injection techniques for axillary block in adults undergoing surgery of the distal upper limb. We excluded trials using ultrasound-guided techniques. Independent study selection, risk of bias assessment and data extraction were performed by at least two investigators. We undertook meta-analysis. The 21 included trials involved a total of 2148 participants who received regional anaesthesia for hand, wrist, forearm or elbow surgery. Risk of bias assessment indicated that trial design and conduct were generally adequate; the most common areas of weakness were in blinding and allocation concealment.Eight trials comparing double versus single injections showed a statistically significant decrease in primary anaesthesia failure (risk ratio (RR 0.51), 95% confidence interval (CI) 0.30 to 0.85). Subgroup analysis by method of nerve location showed that the effect size was greater when neurostimulation was used rather than the transarterial technique.Eight trials comparing multiple with single injections showed a statistically significant decrease in primary anaesthesia failure (RR 0.25, 95% CI 0.14 to 0.44) and of incomplete motor block (RR 0.61, 95% CI 0.39 to 0.96) in the multiple injection group.Eleven trials comparing multiple with double injections showed a statistically significant decrease in primary anaesthesia failure (RR 0.28, 95% CI 0.20 to 0.40) and of incomplete motor block (RR 0.55, 95% CI 0.36 to 0.85) in the multiple injection group.Tourniquet pain was significantly reduced with multiple injections compared with double injections (RR 0.53, 95% CI 0.33 to 0.84). Otherwise there were no statistically significant differences between groups in any of the three comparisons on secondary analgesia failure, complications and patient discomfort. The time for block performance was significantly shorter for single and double injections compared with multiple injections. This review provides evidence that multiple-injection techniques using nerve stimulation for axillary plexus block produce more effective anaesthesia than either double or single-injection techniques. However, there was insufficient evidence for a significant difference in other outcomes, including safety.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-01
... Friday, except Federal holidays. The AD docket contains this proposed AD, the regulatory evaluation, any... three criteria address the failure types under evaluation: single failures, single failures in... evaluations included consideration of previous actions taken that may mitigate the need for further action...
An experimental evaluation of software redundancy as a strategy for improving reliability
NASA Technical Reports Server (NTRS)
Eckhardt, Dave E., Jr.; Caglayan, Alper K.; Knight, John C.; Lee, Larry D.; Mcallister, David F.; Vouk, Mladen A.; Kelly, John P. J.
1990-01-01
The strategy of using multiple versions of independently developed software as a means to tolerate residual software design faults is suggested by the success of hardware redundancy for tolerating hardware failures. Although, as generally accepted, the independence of hardware failures resulting from physical wearout can lead to substantial increases in reliability for redundant hardware structures, a similar conclusion is not immediate for software. The degree to which design faults are manifested as independent failures determines the effectiveness of redundancy as a method for improving software reliability. Interest in multi-version software centers on whether it provides an adequate measure of increased reliability to warrant its use in critical applications. The effectiveness of multi-version software is studied by comparing estimates of the failure probabilities of these systems with the failure probabilities of single versions. The estimates are obtained under a model of dependent failures and compared with estimates obtained when failures are assumed to be independent. The experimental results are based on twenty versions of an aerospace application developed and certified by sixty programmers from four universities. Descriptions of the application, development and certification processes, and operational evaluation are given together with an analysis of the twenty versions.
Single wheel hub motor failures and their impact on vehicle and driver behaviour
NASA Astrophysics Data System (ADS)
Wanner, Daniel; Kreußlein, Maria; Augusto, Bruno; Drugge, Lars; Stensson Trigell, Annika
2016-10-01
This research work studies the impact of single wheel hub motor failures on the dynamic behaviour of electric vehicles and the corresponding driver reactions. An experimental study in a moving-base driving simulator is conducted to analyse the influence of single wheel hub motor failures for motorway speeds. Driver reaction times are derived from the measured data and discussed in their experimental context. The failure is rated objectively on the dynamic behaviour of the vehicle and compared to the subjective evaluation. Findings indicate that critical traffic situations impairing traffic safety can occur for motorway speeds. Clear counteractions by the drivers had to be taken.
Review on failure prediction techniques of composite single lap joint
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ab Ghani, A.F., E-mail: ahmadfuad@utem.edu.my; Rivai, Ahmad, E-mail: ahmadrivai@utem.edu.my
2016-03-29
Adhesive bonding is the most appropriate joining method in construction of composite structures. The use of reliable design and prediction technique will produce better performance of bonded joints. Several papers from recent papers and journals have been reviewed and synthesized to understand the current state of the art in this area. It is done by studying the most relevant analytical solutions for composite adherends with start of reviewing the most fundamental ones involving beam/plate theory. It is then extended to review single lap joint non linearity and failure prediction and finally on the failure prediction on composite single lap joint.more » The review also encompasses the finite element modelling part as tool to predict the elastic response of composite single lap joint and failure prediction numerically.« less
Martens, Pieter; Vercammen, Jan; Ceyssens, Wendy; Jacobs, Linda; Luwel, Evert; Van Aerde, Herwig; Potargent, Peter; Renaers, Monique; Dupont, Matthias; Mullens, Wilfried
2018-01-17
In patients with palliative end-stage heart failure, interventions that could provide symptomatic relief and prevent hospital admissions are important. Ambulatory continuous intravenous inotropes have been advocated by guidelines for such a purpose. We sought to determine the effect of intravenous dobutamine on symptomatic status, hospital stay, mortality, and cost expenditure. All consecutive end-stage heart failure patients not amenable for advanced therapies and discharged with continuous intravenous home dobutamine from a single tertiary centre between April 2011 and January 2017 were retrospectively analysed. Dobutamine (fixed dose) was infused through a single-lumen central venous catheter with a small pump that was refilled by a nurse on a daily basis. Symptomatic status was longitudinally assessed as the change in New York Heart Association class and patient global assessment scale. Antecedent and incident heart failure hospitalizations were determined in a paired fashion, and cost impact was assessed. A total of 21 patients (age 77 ± 9 years) were followed up for 869 ± 647 days. At first follow-up (6 ± 1 weeks) after the initiation of dobutamine, patients had a significant improvement in New York Heart Association class (-1.29 ± 0.64; P < 0.001), global assessment scale (<0.001), and N-terminal pro-brain natriuretic peptide (6247 vs. 2543 pg/mL; P = 0.033). Incident heart failure hospitalizations assessed at 3, 6, and 12 months were significantly reduced (P < 0.001 for all) in comparison with antecedent heart failure hospitalizations over the same time period. Cost expenditure was significantly lower at 3 (P < 0.001), 6 (P = 0.005), and 12 months (P = 0.001) after initiation of dobutamine. Mortality rate at 1 year was 48% with 9/12 (75%) patients dying at home, most often from progressive pump failure. Continuous intravenous home dobutamine in patients with palliative end-stage heart failure is feasible and associated with improved symptomatic status, heart failure hospitalizations, and health-care-related costs. Nevertheless, results should be interpreted in the context of the small and retrospective design. Larger studies are necessary to evaluate the effect of dobutamine in palliative end-stage heart failure. © 2018 The Authors. ESC Heart Failure published by John Wiley & Sons Ltd on behalf of the European Society of Cardiology.
Buchhorn, G. H.; Gilbert, F.; Spahn, G.; Schultz, W.; Klinger, H.-M.
2010-01-01
Aim This experimental study aimed to compare the load-to-failure rate and stiffness of single- versus double-row suture techniques for repairing rotator cuff lesions using two different suture materials. Additionally, the mode of failure of each repair was evaluated. Method In 32 sheep shoulders, a standardized tear of the infraspinatus tendon was created. Then, n = 8 specimen were randomized to four repair methods: (1) Double-row Anchor Ethibond® coupled with polyester sutures, USP No. 2; (2) Double-Row Anchor HiFi® with polyblend polyethylene sutures, USP No. 2; (3) Single-Row Anchor Ethibond® coupled with braided polyester sutures, USP No. 2; and (4) Single-Row Anchor HiFi® with braided polyblend polyethylene sutures, USP No. 2. Arthroscopic Mason–Allen stitches were placed (single-row) and combined with medial horizontal mattress stitches (double-row). All specimens were loaded to failure at a constant displacement rate on a material testing machine. Results Group 4 showed lowest load-to-failure result with 155.7 ± 31.1 N compared to group 1 (293.4 ± 16.1 N) and group 2 (397.7 ± 7.4 N) (P < 0.001). Stiffness was highest in group 2 (162 ± 7.3 N/mm) and lowest in group 4 (84.4 ± 19.9 mm) (P < 0.001). In group 4, the main cause of failure was due to the suture cutting through the tendon (n = 6), a failure case observed in only n = 1 specimen in group 2 (P < 0.001). Conclusions A double-row technique combined with arthroscopic Mason-Allen/horizontal mattress stitches provides high initial failure strength and may minimize the risk of the polyethylene sutures cutting through the tendon in rotator cuff repair when a single load force is used. PMID:20049605
Probabilistic safety analysis of earth retaining structures during earthquakes
NASA Astrophysics Data System (ADS)
Grivas, D. A.; Souflis, C.
1982-07-01
A procedure is presented for determining the probability of failure of Earth retaining structures under static or seismic conditions. Four possible modes of failure (overturning, base sliding, bearing capacity, and overall sliding) are examined and their combined effect is evaluated with the aid of combinatorial analysis. The probability of failure is shown to be a more adequate measure of safety than the customary factor of safety. As Earth retaining structures may fail in four distinct modes, a system analysis can provide a single estimate for the possibility of failure. A Bayesian formulation of the safety retaining walls is found to provide an improved measure for the predicted probability of failure under seismic loading. The presented Bayesian analysis can account for the damage incurred to a retaining wall during an earthquake to provide an improved estimate for its probability of failure during future seismic events.
Silicon Carbide Power Device Performance Under Heavy-Ion Irradiation
NASA Technical Reports Server (NTRS)
Lauenstein, Jean-Marie; Casey, Megan; Topper, Alyson; Wilcox, Edward; Phan, Anthony; Ikpe, Stanley; LaBel, Ken
2015-01-01
Heavy-ion induced degradation and catastrophic failure data for SiC power MOSFETs and Schottky diodes are examined to provide insight into the challenge of single-event effect hardening of SiC power devices.
Natera, Luis; Consigliere, Paolo; Witney-Lagen, Caroline; Brugera, Juan; Sforza, Giuseppe; Atoun, Ehud; Levy, Ofer
2017-10-01
Many techniques of arthroscopic rotator cuff repair have been described. No significant differences in clinical outcomes or rerupture rates have been observed when comparing single-row with double-row methods. Not all single- and double-row repairs are the same. The details of the technique used are crucial. It has been shown that the suture-tendon interface is the weakest point of the reconstruction. Therefore, the biomechanical properties of rotator cuff repairs might be influenced more by the suture configuration than by the number of anchors or by the number of rows involved. Techniques that secure less amount of tendon over a smaller area of the healing zone might be expected to have higher failure rates. The way the sutures of the "parachute technique" are configured represents a quadruple mattress that increases the contact and pressure between the tendon and its footprint and increases the primary load to failure of the repair. We present a simple and effective single-row technique that involves the biomechanical and biological advantages related to the increased contact area and pressure between the cuff and its footprint.
Rate-dependent activation failure in isolated cardiac cells and tissue due to Na+ channel block.
Varghese, Anthony; Spindler, Anthony J; Paterson, David; Noble, Denis
2015-11-15
While it is well established that class-I antiarrhythmics block cardiac sodium channels, the mechanism of action of therapeutic levels of these drugs is not well understood. Using a combination of mathematical modeling and in vitro experiments, we studied the failure of activation of action potentials in single ventricular cells and in tissue caused by Na(+) channel block. Our computations of block and unblock of sodium channels by a theoretical class-Ib antiarrhythmic agent predict differences in the concentrations required to cause activation failure in single cells as opposed to multicellular preparations. We tested and confirmed these in silico predictions with in vitro experiments on isolated guinea-pig ventricular cells and papillary muscles stimulated at various rates (2-6.67 Hz) and exposed to various concentrations (5 × 10(-6) to 500 × 10(-6) mol/l) of lidocaine. The most salient result was that whereas large doses (5 × 10(-4) mol/l or higher) of lidocaine were required to inhibit action potentials temporarily in single cells, much lower doses (5 × 10(-6) mol/l), i.e., therapeutic levels, were sufficient to have the same effect in papillary muscles: a hundredfold difference. Our experimental results and mathematical analysis indicate that the syncytial nature of cardiac tissue explains the effects of clinically relevant doses of Na(+) channel blockers. Copyright © 2015 the American Physiological Society.
Rate-dependent activation failure in isolated cardiac cells and tissue due to Na+ channel block
Spindler, Anthony J.; Paterson, David; Noble, Denis
2015-01-01
While it is well established that class-I antiarrhythmics block cardiac sodium channels, the mechanism of action of therapeutic levels of these drugs is not well understood. Using a combination of mathematical modeling and in vitro experiments, we studied the failure of activation of action potentials in single ventricular cells and in tissue caused by Na+ channel block. Our computations of block and unblock of sodium channels by a theoretical class-Ib antiarrhythmic agent predict differences in the concentrations required to cause activation failure in single cells as opposed to multicellular preparations. We tested and confirmed these in silico predictions with in vitro experiments on isolated guinea-pig ventricular cells and papillary muscles stimulated at various rates (2–6.67 Hz) and exposed to various concentrations (5 × 10−6 to 500 × 10−6 mol/l) of lidocaine. The most salient result was that whereas large doses (5 × 10−4 mol/l or higher) of lidocaine were required to inhibit action potentials temporarily in single cells, much lower doses (5 × 10−6 mol/l), i.e., therapeutic levels, were sufficient to have the same effect in papillary muscles: a hundredfold difference. Our experimental results and mathematical analysis indicate that the syncytial nature of cardiac tissue explains the effects of clinically relevant doses of Na+ channel blockers. PMID:26342072
Care management for low-risk patients with heart failure: a randomized, controlled trial.
DeBusk, Robert Frank; Miller, Nancy Houston; Parker, Kathleen Marie; Bandura, Albert; Kraemer, Helena Chmura; Cher, Daniel Joseph; West, Jeffrey Alan; Fowler, Michael Bruce; Greenwald, George
2004-10-19
Nurse care management programs for patients with chronic illness have been shown to be safe and effective. To determine whether a telephone-mediated nurse care management program for heart failure reduced the rate of rehospitalization for heart failure and for all causes over a 1-year period. Randomized, controlled trial of usual care with nurse management versus usual care alone in patients hospitalized for heart failure from May 1998 through October 2001. 5 northern California hospitals in a large health maintenance organization. Of 2786 patients screened, 462 met clinical criteria for heart failure and were randomly assigned (228 to intervention and 234 to usual care). Nurse care management provided structured telephone surveillance and treatment for heart failure and coordination of patients' care with primary care physicians. Time to first rehospitalization for heart failure or for any cause and time to a combined end point of first rehospitalization, emergency department visit, or death. At 1 year, half of the patients had been rehospitalized at least once and 11% had died. Only one third of rehospitalizations were for heart failure. The rate of first rehospitalization for heart failure was similar in both groups (proportional hazard, 0.85 [95% CI, 0.46 to 1.57]). The rate of all-cause rehospitalization was similar (proportional hazard, 0.98 [CI, 0.76 to 1.27]). The findings of this study, conducted in a single health care system, may not be generalizable to other health care systems. The overall effect of the intervention was minor. Among patients with heart failure at low risk on the basis of sociodemographic and medical attributes, nurse care management did not statistically significantly reduce rehospitalizations for heart failure or for any cause. Such programs may be less effective for patients at low risk than those at high risk.
The Genomic Architecture of Sporadic Heart Failure
Dorn, Gerald W
2011-01-01
Common or sporadic systolic heart failure (heart failure) is the clinical syndrome of insufficient forward cardiac output resulting from myocardial disease. Most heart failure is the consequence of ischemic or idiopathic cardiomyopathy. There is a clear familial predisposition to heart failure, with a genetic component estimated to confer between 20 and 30% of overall risk. The multifactorial etiology of this syndrome has complicated identification of its genetic underpinnings. Until recently, almost all genetic studies of heart failure were designed and deployed according to the common disease-common variant hypothesis, in which individual risk alleles impart a small positive or negative effect and overall genetic risk is the cumulative impact of all functional genetic variations. Early studies employed a candidate gene approach, focused mainly on factors within adrenergic and renin-angiotensin pathways that affect heart failure progression and are targeted by standard pharmacotherapeutics. Many of these reported allelic associations with heart failure have not been replicated. However, the preponderance of data support risk-modifier effects for the Arg389Gly polymorphism of β1-adrenergic receptors and the intron 16 in/del polymorphism of angiotensin converting enzyme. Recent unbiased studies using genome-wide single nucleotide polymorphism (SNP) microarrays have shown fewer positive results than when these platforms were applied to hypertension, myocardial infarction, or diabetes, possibly reflecting the complex etiology of heart failure. A new cardiovascular gene-centric sub-genome SNP array identified a common heat failure risk allele at 1p36 in multiple independent cohorts, but the biological mechanism for this association is still uncertain. It is likely that common gene polymorphisms account for only a fraction of individual genetic heart failure risk, and future studies using deep resequencing are likely to identify rare gene variants with larger biological effects. PMID:21566223
Efird, Chad; Traub, Shaun; Baldini, Todd; Rioux-Forker, Dana; Spalazzi, Jeffrey P; Davisson, Twana; Hawkins, Monica; McCarty, Eric
2013-08-01
The purpose of this study was to compare the gap formation during cyclic loading, maximum repair strength, and failure mode of single-row full-thickness supraspinatus repairs performed using 2 knotless suture anchors with differing internal suture-retention mechanisms in a human cadaver model. Nine matched pairs of cadaver shoulders were used. Full-thickness tears were induced by detaching the supraspinatus tendon from the greater tuberosity. Single-row repairs were performed with either type I (Opus Magnum PI; ArthroCare, Austin, Texas) or type II (ReelX STT; Stryker, Mahwah, New Jersey) knotless suture anchors. The repaired tendon was cycled from 10 to 90 N for 500 cycles, followed by load to failure. Gap formation was measured at 5, 100, 200, 300, 400, and 500 cycles with a video digitizing system. Anchor type or location (anterior or posterior) had no effect on gap formation during cyclic loading regardless of position (anterior, P=.385; posterior, P=.389). Maximum load to failure was significantly greater (P=.018) for repairs performed with type II anchors (288±62 N) compared with type I anchors (179±39 N). Primary failure modes were anchor pullout and tendon tearing for type II anchors and suture slippage through the anchor for type I anchors. The internal ratcheting suture-retention mechanism of type II anchors may have helped this anchor outperform the suture-cinching mechanism of type I anchors by supporting significantly higher loads before failure and minimizing suture slippage, potentially leading to stronger repairs clinically. Copyright 2013, SLACK Incorporated.
Paulsson, Anna K.; Holmes, Jordan A.; Peiffer, Ann M.; Miller, Lance D.; Liu, Wennuan; Xu, Jianfeng; Hinson, William H.; Lesser, Glenn J.; Laxton, Adrian W.; Tatter, Stephen B.; Debinski, Waldemar
2014-01-01
We investigate the differences in molecular signature and clinical outcomes between multiple lesion glioblastoma (GBM) and single focus GBM in the modern treatment era. Between August 2000 and May 2010, 161 patients with GBM were treated with modern radiotherapy techniques. Of this group, 33 were considered to have multiple lesion GBM (25 multifocal and 8 multicentric). Patterns of failure, time to progression and overall survival were compared based on whether the tumor was considered a single focus or multiple lesion GBM. Genomic groupings and methylation status were also investigated as a possible predictor of multifocality in a cohort of 41 patients with available tissue for analysis. There was no statistically significant difference in overall survival (p < 0.3) between the multiple lesion tumors (8.2 months) and single focus GBM (11 months). Progression free survival was superior in the single focus tumors (7.1 months) as compared to multi-focal (5.6 months, p = 0.02). For patients with single focus, multifocal and multicentric GBM, 81, 76 and 88 % of treatment failures occurred in the 60 Gy volume (p < 0.5), while 54, 72, and 38 % of treatment failures occurred in the 46 Gy volume (p < 0.4). Out of field failures were rare in both single focus and multiple foci GBM (7 vs 3 %). Genomic groupings and methylation status were not found to predict for multifocality. Patterns of failure, survival and genomic signatures for multiple lesion GBM do not appreciably differ when compared to single focus tumors. PMID:24990827
The role of shear and tensile failure in dynamically triggered landslides
Gipprich, T.L.; Snieder, R.K.; Jibson, R.W.; Kimman, W.
2008-01-01
Dynamic stresses generated by earthquakes can trigger landslides. Current methods of landslide analysis such as pseudo-static analysis and Newmark's method focus on the effects of earthquake accelerations on the landslide mass to characterize dynamic landslide behaviour. One limitation of these methods is their use Mohr-Coulomb failure criteria, which only accounts for shear failure, but the role of tensile failure is not accounted for. We develop a limit-equilibrium model to investigate the dynamic stresses generated by a given ground motion due to a plane wave and use this model to assess the role of shear and tensile failure in the initiation of slope instability. We do so by incorporating a modified Griffith failure envelope, which combines shear and tensile failure into a single criterion. Tests of dynamic stresses in both homogeneous and layered slopes demonstrate that two modes of failure exist, tensile failure in the uppermost meters of a slope and shear failure at greater depth. Further, we derive equations that express the dynamic stress in the near-surface in the acceleration measured at the surface. These equations are used to approximately define the depth range for each mechanism of failure. The depths at which these failure mechanisms occur suggest that shear and tensile failure might collaborate in generating slope failure. ?? 2007 The Authors Journal compilation ?? 2007 RAS.
Clinical risk analysis with failure mode and effect analysis (FMEA) model in a dialysis unit.
Bonfant, Giovanna; Belfanti, Pietro; Paternoster, Giuseppe; Gabrielli, Danila; Gaiter, Alberto M; Manes, Massimo; Molino, Andrea; Pellu, Valentina; Ponzetti, Clemente; Farina, Massimo; Nebiolo, Pier E
2010-01-01
The aim of clinical risk management is to improve the quality of care provided by health care organizations and to assure patients' safety. Failure mode and effect analysis (FMEA) is a tool employed for clinical risk reduction. We applied FMEA to chronic hemodialysis outpatients. FMEA steps: (i) process study: we recorded phases and activities. (ii) Hazard analysis: we listed activity-related failure modes and their effects; described control measures; assigned severity, occurrence and detection scores for each failure mode and calculated the risk priority numbers (RPNs) by multiplying the 3 scores. Total RPN is calculated by adding single failure mode RPN. (iii) Planning: we performed a RPNs prioritization on a priority matrix taking into account the 3 scores, and we analyzed failure modes causes, made recommendations and planned new control measures. (iv) Monitoring: after failure mode elimination or reduction, we compared the resulting RPN with the previous one. Our failure modes with the highest RPN came from communication and organization problems. Two tools have been created to ameliorate information flow: "dialysis agenda" software and nursing datasheets. We scheduled nephrological examinations, and we changed both medical and nursing organization. Total RPN value decreased from 892 to 815 (8.6%) after reorganization. Employing FMEA, we worked on a few critical activities, and we reduced patients' clinical risk. A priority matrix also takes into account the weight of the control measures: we believe this evaluation is quick, because of simple priority selection, and that it decreases action times.
Radiation effects and mitigation strategies for modern FPGAs
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stettler, M. W.; Caffrey, M. P.; Graham, P. S.
2004-01-01
Field Programmable Gate Array devices have become the technology of choice in small volume modern instrumentation and control systems. These devices have always offered significant advantages in flexibility, and recent advances in fabrication have greatly increased logic capacity, substantially increasing the number of applications for this technology. Unfortunately, the increased density (and corresponding shrinkage of process geometry), has made these devices more susceptible to failure due to external radiation. This has been an issue for space based systems for some time, but is now becoming an issue for terrestrial systems in elevated radiation environments and commercial avionics as well. Characterizingmore » the failure modes of Xilinx FPGAs, and developing mitigation strategies is the subject of ongoing research by a consortium of academic, industrial, and governmental laboratories. This paper presents background information of radiation effects and failure modes, as well as current and future mitigation techniques. In particular, the availability of very large FPGA devices, complete with generous amounts of RAM and embedded processor(s), has led to the implementation of complete digital systems on a single device, bringing issues of system reliability and redundancy management to the chip level. Radiation effects on a single FPGA are increasingly likely to have system level consequences, and will need to be addressed in current and future designs.« less
NASA Technical Reports Server (NTRS)
Telesman, Jack; Kantzos, Peter
1988-01-01
An in situ fatigue loading stage inside a scanning electron microscope (SEM) was used to determine the fatigue crack growth behavior of a PWA 1480 single-crystal nickel-based superalloy. The loading stage permits real-time viewing of the fatigue damage processes at high magnification. The PWA 1480 single-crystal, single-edge notch specimens were tested with the load axis parallel to the (100) orientation. Two distinct fatigue failure mechanisms were identified. The crack growth rate differed substantially when the failure occurred on a single slip system in comparison to multislip system failure. Two processes by which crack branching is produced were identified and are discussed. Also discussed are the observed crack closure mechanisms.
Radiation Tests on 2Gb NAND Flash Memories
NASA Technical Reports Server (NTRS)
Nguyen, Duc N.; Guertin, Steven M.; Patterson, J. D.
2006-01-01
We report on SEE and TID tests of highly scaled Samsung 2Gbits flash memories. Both in-situ and biased interval irradiations were used to characterize the response of the total accumulated dose failures. The radiation-induced failures can be categorized as followings: single event upset (SEU) read errors in biased and unbiased modes, write errors, and single-event-functional-interrupt (SEFI) failures.
Failure rate of single dose methotrexate in managment of ectopic pregnancy.
Sendy, Feras; AlShehri, Eman; AlAjmi, Amani; Bamanie, Elham; Appani, Surekha; Shams, Taghreed
2015-01-01
Background. One of the treatment modalities for ectopic pregnancy is methotrexate. The purpose of this study is to identify the failure rate of methotrexate in treating patients with ectopic pregnancy as well as the risk factors leading to treatment failure. Methods. A retrospective chart review of 225 patients who received methotrexate as a primary management option for ectopic pregnancy. Failure of single dose of methotrexate was defined as drop of BHCG level less than or equal to 14% in the seventh day after administration of methotrexate. Results. 225 patients had methotrexate. Most of the patients (151 (67%)) received methotrexate based on the following formula: f 50 mg X body surface area. Single dose of methotrexate was successful in 72% (162/225) of the patients. 28% (63/225) were labeled as failure of single dose of methotrexate because of suboptimal drop in BhCG. 63% (40/63) of failure received a second dose of methotrexate, and 37% (23/63) underwent surgical treatment. Among patient who received initial dose of methotrexate, 71% had moderate or severe pain, and 58% had ectopic mass size of more than 4 cm on ultrasound. Conclusion. Liberal use of medical treatment of ectopic pregnancy results in 71% success rate.
Christianto, S; Lau, A; Li, K Y; Yang, W F; Su, Y X
2018-05-01
Venous compromise is still the most common cause of free flap failure. The use of two venous anastomoses has been advocated to reduce venous compromise. However, the effectiveness of this approach remains controversial. A systematic review and cumulative meta-analysis was performed to assess the effect of one versus two venous anastomoses on venous compromise and free flap failure in head and neck microsurgical reconstruction. A total of 27 articles reporting 7389 flaps were included in this study. On comparison of one versus two venous anastomoses, the odds ratio (OR) for flap failure was 1.66 (95% confidence interval 1.11-2.50; P=0.014) and for venous compromise was 1.50 (95% confidence interval 1.10-2.05; P=0.011), suggesting a significant increase in the flap failure rate and venous compromise rate in the single venous anastomosis group. These results show that the execution of two venous anastomoses has significant effects on reducing the vascular compromise and free flap failure rate in head and neck reconstruction. Copyright © 2018 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.
Independent Orbiter Assessment (IOA): Analysis of the remote manipulator system
NASA Technical Reports Server (NTRS)
Tangorra, F.; Grasmeder, R. F.; Montgomery, A. D.
1987-01-01
The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA approach features a top-down analysis of the hardware to determine failure modes, criticality, and potential critical items (PCIs). To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. The independent analysis results for the Orbiter Remote Manipulator System (RMS) are documented. The RMS hardware and software are primarily required for deploying and/or retrieving up to five payloads during a single mission, capture and retrieve free-flying payloads, and for performing Manipulator Foot Restraint operations. Specifically, the RMS hardware consists of the following components: end effector; displays and controls; manipulator controller interface unit; arm based electronics; and the arm. The IOA analysis process utilized available RMS hardware drawings, schematics and documents for defining hardware assemblies, components and hardware items. Each level of hardware was evaluated and analyzed for possible failure modes and effects. Criticality was assigned based upon the severity of the effect for each failure mode. Of the 574 failure modes analyzed, 413 were determined to be PCIs.
Observations of Single Event Failure in Power MOSFETS
NASA Technical Reports Server (NTRS)
Nichols, D.; McCarty, K.; Coss, J.
1994-01-01
The first compendium of single event test data for power MOSFETs provides failure thresholds from burnout or gate rupture for over 100 devices of eight manufacturers. Ordering the data has also provided some useful insights.
Reed, Shelby D.; Neilson, Matthew P.; Gardner, Matthew; Li, Yanhong; Briggs, Andrew H.; Polsky, Daniel E.; Graham, Felicia L.; Bowers, Margaret T.; Paul, Sara C.; Granger, Bradi B.; Schulman, Kevin A.; Whellan, David J.; Riegel, Barbara; Levy, Wayne C.
2015-01-01
Background Heart failure disease management programs can influence medical resource use and quality-adjusted survival. Because projecting long-term costs and survival is challenging, a consistent and valid approach to extrapolating short-term outcomes would be valuable. Methods We developed the Tools for Economic Analysis of Patient Management Interventions in Heart Failure (TEAM-HF) Cost-Effectiveness Model, a Web-based simulation tool designed to integrate data on demographic, clinical, and laboratory characteristics, use of evidence-based medications, and costs to generate predicted outcomes. Survival projections are based on a modified Seattle Heart Failure Model (SHFM). Projections of resource use and quality of life are modeled using relationships with time-varying SHFM scores. The model can be used to evaluate parallel-group and single-cohort designs and hypothetical programs. Simulations consist of 10,000 pairs of virtual cohorts used to generate estimates of resource use, costs, survival, and incremental cost-effectiveness ratios from user inputs. Results The model demonstrated acceptable internal and external validity in replicating resource use, costs, and survival estimates from 3 clinical trials. Simulations to evaluate the cost-effectiveness of heart failure disease management programs across 3 scenarios demonstrate how the model can be used to design a program in which short-term improvements in functioning and use of evidence-based treatments are sufficient to demonstrate good long-term value to the health care system. Conclusion The TEAM-HF Cost-Effectiveness Model provides researchers and providers with a tool for conducting long-term cost-effectiveness analyses of disease management programs in heart failure. PMID:26542504
Biomechanical Analysis of Suture Anchor vs Tenodesis Screw for FHL Transfer.
Drakos, Mark C; Gott, Michael; Karnovsky, Sydney C; Murphy, Conor I; DeSandis, Bridget A; Chinitz, Noah; Grande, Daniel; Chahine, Nadeen
2017-07-01
Chronic Achilles injury is often treated with flexor hallucis longus (FHL) tendon transfer to the calcaneus using 1 or 2 incisions. A single incision avoids the risks of extended dissections yet yields smaller grafts, which may limit fixation options. We investigated the required length of FHL autograft and biomechanical profiles for suture anchor and biotenodesis screw fixation. Single-incision FHL transfer with suture anchor or biotenodesis screw fixation to the calcaneus was performed on 20 fresh cadaveric specimens. Specimens were cyclically loaded until maximal load to failure. Length of FHL tendon harvest, ultimate load, stiffness, and mode of failure were recorded. Tendon harvest length needed for suture anchor fixation was 16.8 ± 2.1 mm vs 29.6 ± 2.4 mm for biotenodesis screw ( P = .002). Ultimate load to failure was not significantly different between groups. A significant inverse correlation existed between failure load and donor age when all specimens were pooled (ρ = -0.49, P < .05). Screws in younger specimens (fewer than 70) resulted in significantly greater failure loads ( P < .03). No difference in stiffness was found between groups. Modes of failure for screw fixation were either tunnel pullout (n = 6) or tendon rupture (n = 4). Anchor failure occurred mostly by suture breakage (n = 8). Adequate FHL tendon length could be harvested through a single posterior incision for fixation to the calcaneus with either fixation option, but suture anchor required significantly less graft length. Stiffness, fixation strength, and load to failure were comparable between groups. An inverse correlation existed between failure load and donor age. Younger specimens with screw fixation demonstrated significantly greater failure loads. Adequate harvest length for FHL transfer could be achieved with a single posterior incision. There was no difference in strength of fixation between suture anchor and biotenodesis screw.
Heart failure: not a single organ disease but a multisystem syndrome.
Warriner, David; Sheridan, Paul; Lawford, Patricia
2015-06-01
Heart failure is not simply a single organ disease; rather it is a complex multi-system clinical syndrome, with impairment of endocrine, haematological, musculoskeletal, renal, respiratory and vascular systems, which influence morbidity and mortality.
Therapeutic potential of microRNAs in heart failure.
Dorn, Gerald W
2010-05-01
There is an ongoing explosion of information about microRNAs (miRs) in cardiac disease. These small noncoding RNAs regulate protein expression by destabilization and translational inhibition of target mRNAs. Similar to mRNAs, miRs are regulated in cardiac hypertrophy and heart failure, but miR expression profiles appear to be more sensitive than mRNA signatures to changes in clinical status, suggesting that miR levels in myocardium or plasma could enhance clinical diagnostics. Single miRs can target dozens or hundreds of different mRNAs, complicating attempts to determine their individual physiologic effects. However, manipulating individual miRs by overexpression or gene ablation in experimental models has begun to unravel this conundrum: Single miRs tend to regulate numerous effectors within the same functional pathway, producing a coherent physiologic response via multiple parallel perturbations. miRs are attractive nodal therapeutic targets, and stable miR mimetics (agomiRs) and antagonists (antagomiRs) are being evaluated to prevent or reverse heart failure.
Effects of Ion Atomic Number on Single-Event Gate Rupture (SEGR) Susceptibility of Power MOSFETs
NASA Technical Reports Server (NTRS)
Lauenstein, J.-M.; Goldsman, N.; Liu, S.; Titus, J.; Ladbury, R. L.; Kim, H. S.; Phan, A. M.; Zafrani, M.; Sherman, P.
2011-01-01
The relative importance of heavy-ion interaction with the oxide, charge ionized in the epilayer, and charge ionized in the drain substrate, on the bias for SEGR failure is experimentally investigated.
14 CFR 31.25 - Factor of safety.
Code of Federal Regulations, 2010 CFR
2010-01-01
... envelope stress. (c) A factor of safety of at least five must be used in the design of all fibrous or non... any single failure will not jeopardize safety of flight. (d) In applying factors of safety, the effect...
NASA Technical Reports Server (NTRS)
Pineda, Evan J.; Waas, Anthony M.
2011-01-01
A thermodynamically-based work potential theory for modeling progressive damage and failure in fiber-reinforced laminates is presented. The current, multiple-internal state variable (ISV) formulation, enhanced Schapery theory (EST), utilizes separate ISVs for modeling the effects of damage and failure. Damage is considered to be the effect of any structural changes in a material that manifest as pre-peak non-linearity in the stress versus strain response. Conversely, failure is taken to be the effect of the evolution of any mechanisms that results in post-peak strain softening. It is assumed that matrix microdamage is the dominant damage mechanism in continuous fiber-reinforced polymer matrix laminates, and its evolution is controlled with a single ISV. Three additional ISVs are introduced to account for failure due to mode I transverse cracking, mode II transverse cracking, and mode I axial failure. Typically, failure evolution (i.e., post-peak strain softening) results in pathologically mesh dependent solutions within a finite element method (FEM) setting. Therefore, consistent character element lengths are introduced into the formulation of the evolution of the three failure ISVs. Using the stationarity of the total work potential with respect to each ISV, a set of thermodynamically consistent evolution equations for the ISVs is derived. The theory is implemented into commercial FEM software. Objectivity of total energy dissipated during the failure process, with regards to refinements in the FEM mesh, is demonstrated. The model is also verified against experimental results from two laminated, T800/3900-2 panels containing a central notch and different fiber-orientation stacking sequences. Global load versus displacement, global load versus local strain gage data, and macroscopic failure paths obtained from the models are compared to the experiments.
NASA Technical Reports Server (NTRS)
Pineda, Evan J.; Waas, Anthony M.
2012-01-01
A thermodynamically-based work potential theory for modeling progressive damage and failure in fiber-reinforced laminates is presented. The current, multiple-internal state variable (ISV) formulation, enhanced Schapery theory (EST), utilizes separate ISVs for modeling the effects of damage and failure. Damage is considered to be the effect of any structural changes in a material that manifest as pre-peak non-linearity in the stress versus strain response. Conversely, failure is taken to be the effect of the evolution of any mechanisms that results in post-peak strain softening. It is assumed that matrix microdamage is the dominant damage mechanism in continuous fiber-reinforced polymer matrix laminates, and its evolution is controlled with a single ISV. Three additional ISVs are introduced to account for failure due to mode I transverse cracking, mode II transverse cracking, and mode I axial failure. Typically, failure evolution (i.e., post-peak strain softening) results in pathologically mesh dependent solutions within a finite element method (FEM) setting. Therefore, consistent character element lengths are introduced into the formulation of the evolution of the three failure ISVs. Using the stationarity of the total work potential with respect to each ISV, a set of thermodynamically consistent evolution equations for the ISVs is derived. The theory is implemented into commercial FEM software. Objectivity of total energy dissipated during the failure process, with regards to refinements in the FEM mesh, is demonstrated. The model is also verified against experimental results from two laminated, T800/3900-2 panels containing a central notch and different fiber-orientation stacking sequences. Global load versus displacement, global load versus local strain gage data, and macroscopic failure paths obtained from the models are compared to the experiments.
Cerebral blood flow in patients with congestive heart failure treated with captopril.
Paulson, O B; Jarden, J O; Godtfredsen, J; Vorstrup, S
1984-05-31
The effect of captopril on cerebral blood flow was studied in five patients with severe congestive heart failure and in five control subjects. Cerebral blood flow was measured by inhalation of 133xenon and registration of its uptake and washout from the brain by single photon emission computer tomography. In addition, cerebral (internal jugular) venous oxygen tension was determined in the controls. The measurements were made before and 15, 60, and 180 minutes after a single oral dose of captopril (6.25 mg in patients with congestive heart failure and 25 mg in controls). Despite a marked decrease in blood pressure, cerebral blood flow increased slightly in the patients with severe congestive heart failure. When a correction was applied to take account of a change in arterial carbon dioxide tension, however, cerebral blood flow was unchanged after captopril administration even in patients with the greatest decrease in blood pressure, in whom a decrease in cerebral blood flow might have been expected. In the controls, blood pressure was little affected by captopril, whereas a slight, but not statistically significant, decrease in cerebral blood flow was observed. The cerebral venous oxygen tension decreased concomitantly.
Orthopaedic jack for scoliosis surgery purposes: Concept and design
NASA Astrophysics Data System (ADS)
Supriadi, Sugeng; Radhana, Rakha M.; Hidayanto, Taufik Eko; Whulanza, Yudan; Ali, Notario, Nanda; Rahyussalim
2017-02-01
Scoliosis surgery is one of the most difficult orthopedic surgery that have been committed today as the failure rate of orthopedic surgery for adult patients is 15%. Aside from the long duration of surgery, this surgical failure is caused by failure in biomedical instrumentation. Furthermore, this kind of failure is causing inefficiency of the surgery. With current known orthopedic surgery method, three surgeons are needed in a single orthopedic surgery. In fact, a single surgery can take up to 8 hours to be done, which increases the risk of surgical failure. Based on this problem, authors hope that our orthopedic jacks could solve the problem.
Bartlett, Ashley; Wales, Larry; Houfburg, Rodney; Durfee, William K; Griffith, Steven L; Bentley, Ishmael
2013-10-01
In vitro comparative, laboratory experiments. This study developed a laboratory apparatus that measured resistance to failure using pressures similar to intradiscal pressure of a lumbar spinal disk. Various combinations of an anular repair device were compared. Herniated material of the intervertebral disk is removed during a lumbar discectomy; however, the defect in the anulus fibrosus remains and can provide a pathway for future herniation. Repairing the anulus fibrosus could mitigate this reherniation and improve patient outcomes. A pneumatic cylinder was used to increase the pressure of a sealed chamber until artificial nucleus pulposus material was expulsed through either a 3-mm circular (diameter) or a 6-mm slit anular defect created in a surrogate anulus fibrosus. Each unrepaired condition was compared with 3 repaired conditions using a commercially available soft tissue repair system. The repaired conditions included: (1) a single tension band; (2) 2 tension bands in a cruciate pattern; or (3) 2 tension bands in a parallel pattern. Maximum pressure at the point of extrusion of the internal chamber material and failure or nonfailure of the repair was measured. Significant differences were detected (P<0.05) in maximum failure pressures for the nonrepaired (control) versus repaired conditions. With 1 or 2 tension bands repairing the circular defect, the maximum failure pressure increased by approximately 76% and 131%, respectively. In addition, the failure pressure for 2 tension bands in either a cruciate or parallel configuration was not different, and was approximately 32% higher (P<0.05) than a single tension band in the case of the circular defect. Similar results were seen for the slit defect, with the exception that no difference between the repaired conditions (ie, single vs. 2 tension bands) was detected. This laboratory simulation demonstrated that repairing the anulus fibrosus after a discectomy procedure can be beneficial for retaining intradiscal material. The use of 2 tension bands, versus a single tension band, in either a cruciate or parallel configuration may further improve the ability to retain disk material.
Failure mechanisms of thermal barrier coatings exposed to elevated temperatures
NASA Technical Reports Server (NTRS)
Miller, R. A.; Lowell, C. E.
1982-01-01
The failure of a ZrO2-8%Y2O3/Ni-14% Al-0.1% Zr coating system on Rene 41 in Mach 0.3 burner rig tests was characterized. High flame and metal temperatures were employed in order to accelerate coating failure. Failure by delamination was shown to precede surface cracking or spalling. This type of failure could be duplicated by cooling down the specimen after a single long duration isothermal high temperature cycle in a burner rig or a furnace, but only if the atmosphere was oxidizing. Stresses due to thermal expansion mismatch on cooling coupled with the effects of plastic deformation of the bond coat and oxidation of the irregular bond coat are the probable life limiting factors. Heat up stresses alone could not fail the coating in the burner rig tests. Spalling eventually occurs on heat up but only after the coating has already failed through delamination.
Combining System Safety and Reliability to Ensure NASA CoNNeCT's Success
NASA Technical Reports Server (NTRS)
Havenhill, Maria; Fernandez, Rene; Zampino, Edward
2012-01-01
Hazard Analysis, Failure Modes and Effects Analysis (FMEA), the Limited-Life Items List (LLIL), and the Single Point Failure (SPF) List were applied by System Safety and Reliability engineers on NASA's Communications, Navigation, and Networking reConfigurable Testbed (CoNNeCT) Project. The integrated approach involving cross reviews of these reports by System Safety, Reliability, and Design engineers resulted in the mitigation of all identified hazards. The outcome was that the system met all the safety requirements it was required to meet.
Double-Row Capsulolabral Repair Increases Load to Failure and Decreases Excessive Motion.
McDonald, Lucas S; Thompson, Matthew; Altchek, David W; McGarry, Michelle H; Lee, Thay Q; Rocchi, Vanna J; Dines, Joshua S
2016-11-01
Using a cadaver shoulder instability model and load-testing device, we compared biomechanical characteristics of double-row and single-row capsulolabral repairs. We hypothesized a greater reduction in glenohumeral motion and translation and a higher load to failure in a mattress double-row capsulolabral repair than in a single-row repair. In 6 matched pairs of cadaveric shoulders, a capsulolabral injury was created. One shoulder was repaired with a single-row technique, and the other with a double-row mattress technique. Rotational range of motion, anterior-inferior translation, and humeral head kinematics were measured. Load-to-failure testing measured stiffness, yield load, deformation at yield load, energy absorbed at yield load, load to failure, deformation at ultimate load, and energy absorbed at ultimate load. Double-row repair significantly decreased external rotation and total range of motion compared with single-row repair. Both repairs decreased anterior-inferior translation compared with the capsulolabral-injured condition, however, no differences existed between repair types. Yield load in the single-row group was 171.3 ± 110.1 N, and in the double-row group it was 216.1 ± 83.1 N (P = .02). Ultimate load to failure in the single-row group was 224.5 ± 121.0 N, and in the double-row group it was 373.9 ± 172.0 N (P = .05). Energy absorbed at ultimate load in the single-row group was 1,745.4 ± 1,462.9 N-mm, and in the double-row group it was 4,649.8 ± 1,930.8 N-mm (P = .02). In cases of capsulolabral disruption, double-row repair techniques may result in decreased shoulder rotational range of motion and improved load-to-failure characteristics. In cases of capsulolabral disruption, repair techniques with double-row mattress repair may provide more secure fixation. Double-row capsulolabral repair decreases shoulder motion and increases load to failure, yield load, and energy absorbed at yield load more than single-row repair. Published by Elsevier Inc.
Ballistic Limit Equation for Single Wall Titanium
NASA Technical Reports Server (NTRS)
Ratliff, J. M.; Christiansen, Eric L.; Bryant, C.
2009-01-01
Hypervelocity impact tests and hydrocode simulations were used to determine the ballistic limit equation (BLE) for perforation of a titanium wall, as a function of wall thickness. Two titanium alloys were considered, and separate BLEs were derived for each. Tested wall thicknesses ranged from 0.5mm to 2.0mm. The single-wall damage equation of Cour-Palais [ref. 1] was used to analyze the Ti wall's shielding effectiveness. It was concluded that the Cour-Palais single-wall equation produced a non-conservative prediction of the ballistic limit for the Ti shield. The inaccurate prediction was not a particularly surprising result; the Cour-Palais single-wall BLE contains shield material properties as parameters, but it was formulated only from tests of different aluminum alloys. Single-wall Ti shield tests were run (thicknesses of 2.0 mm, 1.5 mm, 1.0 mm, and 0.5 mm) on Ti 15-3-3-3 material custom cut from rod stock. Hypervelocity impact (HVI) tests were used to establish the failure threshold empirically, using the additional constraint that the damage scales with impact energy, as was indicated by hydrocode simulations. The criterion for shield failure was defined as no detached spall from the shield back surface during HVI. Based on the test results, which confirmed an approximately energy-dependent shield effectiveness, the Cour-Palais equation was modified.
Failure Rate of Single Dose Methotrexate in Managment of Ectopic Pregnancy
Sendy, Feras; AlShehri, Eman; AlAjmi, Amani; Bamanie, Elham; Appani, Surekha; Shams, Taghreed
2015-01-01
Background. One of the treatment modalities for ectopic pregnancy is methotrexate. The purpose of this study is to identify the failure rate of methotrexate in treating patients with ectopic pregnancy as well as the risk factors leading to treatment failure. Methods. A retrospective chart review of 225 patients who received methotrexate as a primary management option for ectopic pregnancy. Failure of single dose of methotrexate was defined as drop of BHCG level less than or equal to 14% in the seventh day after administration of methotrexate. Results. 225 patients had methotrexate. Most of the patients (151 (67%)) received methotrexate based on the following formula: f 50 mg X body surface area. Single dose of methotrexate was successful in 72% (162/225) of the patients. 28% (63/225) were labeled as failure of single dose of methotrexate because of suboptimal drop in BhCG. 63% (40/63) of failure received a second dose of methotrexate, and 37% (23/63) underwent surgical treatment. Among patient who received initial dose of methotrexate, 71% had moderate or severe pain, and 58% had ectopic mass size of more than 4 cm on ultrasound. Conclusion. Liberal use of medical treatment of ectopic pregnancy results in 71% success rate. PMID:25861275
Sandhu, Alexander T; Ollendorf, Daniel A; Chapman, Richard H; Pearson, Steven D; Heidenreich, Paul A
2016-11-15
Sacubitril-valsartan therapy reduces cardiovascular mortality compared with enalapril therapy in patients with heart failure with reduced ejection fraction. To evaluate the cost-effectiveness of sacubitril-valsartan versus angiotensin-converting enzyme inhibitor therapy in patients with chronic heart failure. Markov decision model. Clinical trials, observational analyses, reimbursement data from the Centers for Medicare & Medicaid Services, drug pricing databases, and Centers for Disease Control and Prevention life tables. Patients at an average age of 64 years, New York Heart Association (NYHA) class II to IV heart failure, and left ventricular ejection fraction of 0.40 or less. Lifetime. Societal. Treatment with sacubitril-valsartan or lisinopril. Life-years, quality-adjusted life-years (QALYs), costs, heart failure hospitalizations, and incremental cost-effectiveness ratios. The sacubitril-valsartan group experienced 0.08 fewer heart failure hospitalization, 0.69 additional life-year, 0.62 additional QALY, and $29 203 in incremental costs, equating to a cost per QALY gained of $47 053. The cost per QALY gained was $44 531 in patients with NYHA class II heart failure and $58 194 in those with class III or IV heart failure. Sacubitril-valsartan treatment was most sensitive to the duration of improved outcomes, with a cost per QALY gained of $120 623 if the duration was limited to the length of the trial (median, 27 months). No variations in other parameters caused the cost to exceed $100 000 per QALY gained. The benefit of sacubitril-valsartan is based on a single clinical trial. Treatment with sacubitril-valsartan provides reasonable value in reducing cardiovascular mortality and morbidity in patients with NYHA class II to IV heart failure. U.S. Department of Veterans Affairs and Institute for Clinical and Economic Review.
NASA Technical Reports Server (NTRS)
Karplus, Alan K.
1996-01-01
The objective of this exercise is to provide a phenomenological 'hands-on' experience that shows how geometry can affect the load carrying capacity of a material used in construction, how different materials have different failure characteristics, and how construction affects the performance of a composite material. This will be accomplished by building beams of a single material and composite beams of a mixture of materials (popsicle sticks, fiberboard sheets, and tongue depressors); testing these layered beams to determine how and where they fail; and based on the failure analysis, designing a layered beam that will fail in a predicted manner. The students will learn the effects of lamination, adhesion, and geometry in layered beam construction on beam strength and failure location.
Redundant disk arrays: Reliable, parallel secondary storage. Ph.D. Thesis
NASA Technical Reports Server (NTRS)
Gibson, Garth Alan
1990-01-01
During the past decade, advances in processor and memory technology have given rise to increases in computational performance that far outstrip increases in the performance of secondary storage technology. Coupled with emerging small-disk technology, disk arrays provide the cost, volume, and capacity of current disk subsystems, by leveraging parallelism, many times their performance. Unfortunately, arrays of small disks may have much higher failure rates than the single large disks they replace. Redundant arrays of inexpensive disks (RAID) use simple redundancy schemes to provide high data reliability. The data encoding, performance, and reliability of redundant disk arrays are investigated. Organizing redundant data into a disk array is treated as a coding problem. Among alternatives examined, codes as simple as parity are shown to effectively correct single, self-identifying disk failures.
Square-lashing technique in segmental spinal instrumentation: a biomechanical study.
Arlet, Vincent; Draxinger, Kevin; Beckman, Lorne; Steffen, Thomas
2006-07-01
Sublaminar wires have been used for many years for segmental spinal instrumentation in scoliosis surgery. More recently, stainless steel wires have been replaced by titanium cables. However, in rigid scoliotic curves, sublaminar wires or simple cables can either brake or pull out. The square-lashing technique was devised to avoid complications such as cable breakage or lamina cutout. The purpose of the study was therefore to test biomechanically the pull out and failure mode of simple sublaminar constructs versus the square-lashing technique. Individual vertebrae were subjected to pullout testing having one of two different constructs (single loop and square lashing) using either monofilament wire or multifilament cables. Four different methods of fixation were therefore tested: single wire construct, square-lashing wiring construct, single cable construct, and square-lashing cable construct. Ultimate failure load and failure mechanism were recorded. For the single wire the construct failed 12/16 times by wire breakage with an average ultimate failure load of 793 N. For the square-lashing wire the construct failed with pedicle fracture in 14/16, one bilateral lamina fracture, and one wire breakage. Ultimate failure load average was 1,239 N For the single cable the construct failed 12/16 times due to cable breakage (average force 1,162 N). 10/12 of these breakages were where the cable looped over the rod. For the square-lashing cable all of these constructs (16/16) failed by fracture of the pedicle with an average ultimate failure load of 1,388 N. The square-lashing construct had a higher pullout strength than the single loop and almost no cutting out from the lamina. The square-lashing technique with cables may therefore represent a new advance in segmental spinal instrumentation.
Kharmanda, Ghias; Kharma, Mohamed-Yaser
2017-06-01
The objective of this work is to integrate structural optimization and reliability concepts into mini-plate fixation strategy used in symphysis mandibular fractures. The structural reliability levels are next estimated when considering a single failure mode and multiple failure modes. A 3-dimensional finite element model is developed in order to evaluate the ability of reducing the negative effect due to the stabilization of the fracture. Topology optimization process is considered in the conceptual design stage to predict possible fixation layouts. In the detailed design stage, suitable mini-plates are selected taking into account the resulting topology and different anatomical considerations. Several muscle forces are considered in order to obtain realistic predictions. Since some muscles can be cut or harmed during the surgery and cannot operate at its maximum capacity, there is a strong motivation to introduce the loading uncertainties in order to obtain reliable designs. The structural reliability is carried out for a single failure mode and multiple failure modes. The different results are validated with a clinical case of a male patient with symphysis fracture. In this case while use of the upper plate fixation with four holes, only two screws were applied to protect adjacent vital structure. This behavior does not affect the stability of the fracture. The proposed strategy to optimize bone plates leads to fewer complications and second surgeries, less patient discomfort, and shorter time of healing.
Single-event burnout of n-p-n bipolar-junction transistors in hybrid DC/DC converters
NASA Astrophysics Data System (ADS)
Warren, K.; Roth, D.; Kinnison, J.; Pappalardo, R.
2002-12-01
Single-event-induced failure of the Lambda Advanced Analog AMF2805S DC/DC Converter has been traced to burnout of an n-p-n transistor in the MOSFET drive stage. The failures were observed during testing while in inhibit mode only. Modifications to prevent burnout of the drive stage were successfully employed. A discussion of the failure mechanism and consequences for DC/DC converter testing are presented.
Computational hydraulics of a cascade of experimental-scale landside dam failures
NASA Astrophysics Data System (ADS)
Wright, N.; Guan, M.
2015-12-01
Abstract: Landslide dams typically comprise unconsolidated and poorly sorted material, and are vulnerable to rapid failure and breaching, particularly in mountainous areas during high intense rainfalls. A large flash flood with high-concentrated sediment can be formed in a short period, and the magnitude is likely to be amplified along the flow direction due to the inclusion of a large amount of sediment. This can result in significant and sudden flood risk downstream for human life and property. Numerous field evidence has indicated the various risks of landslide dam failures. In general, cascading landslide dams can be formed along the sloping channel due to the randomness and unpredictability of landslides, which complexes the hydraulics of landslide dam failures. The failure process of a single dam and subsequent floods has attracted attention in multidisciplinary studies. However, the dynamic failure process of cascading landslide dams has been poorly understood. From a viewpoint of simulation, this study evaluates the formation and development of rapid sediment-charged floods due to cascading failure of landslide dams through detailed hydro-morphodynamic modelling. The model used is based on shallow water theory and it has been successful in predicting the flow and morphological process during sudden dam-break, as well as full and partial dyke-breach. Various experimental-scale scenarios are modelled, including: (1) failure of a single full dam in a sloping channel, (2) failure of two dams in a sloping channel, (3) failure of multiple landslide dams (four) in a sloping channel. For each scenario, different failure modes (sudden/gradual) and bed boundary (fixed /mobile) are assumed and simulated. The study systematically explores the tempo-spatial evolution of landslide-induced floods (discharge, flow velocity, and flow concentration) and geomorphic properties along the sloping channel. The effects of in-channel erosion and flow-driven sediment from dams on the development of flood process are investigated. The results improve the understanding of the formation and development mechanism of flash floods due to cascading landslide dam failures. The findings are beneficial for downstream flood risk assessment and developing control strategies for landslide-induced floods.
Application of Single Crystal Failure Criteria: Theory and Turbine Blade Case Study
NASA Technical Reports Server (NTRS)
Sayyah, Tarek; Swanson, Gregory R.; Schonberg, W. P.
1999-01-01
The orientation of the single crystal material within a structural component is known to affect the strength and life of the part. The first stage blade of the High Pressure Fuel Turbopump (HPFTP)/ Alternative Turbopump Development (ATD), of the Space Shuttle Main Engine (SSME) was used to study the effects of secondary axis'orientation angles on the failure rate of the blade. A new failure criterion was developed based on normal and shear strains on the primary crystallographic planes. The criterion was verified using low cycle fatigue (LCF) specimen data and a finite element model of the test specimens. The criterion was then used to study ATD/HPFTP first stage blade failure events. A detailed ANSYS finite element model of the blade was used to calculate the failure parameter for the different crystallographic orientations. A total of 297 cases were run to cover a wide range of acceptable orientations within the blade. Those orientations are related to the base crystallographic coordinate system that was created in the ANSYS finite element model. Contour plots of the criterion as a function of orientation for the blade tip and attachment were obtained. Results of the analysis revealed a 40% increase in the failure parameter due to changing of the primary and secondary axes of material orientations. A comparison between failure criterion predictions and actual engine test data was then conducted. The engine test data comes from two ATD/HPFTP builds (units F3- 4B and F6-5D), which were ground tested on the SSME at the Stennis Space Center in Mississippi. Both units experienced cracking of the airfoil tips in multiple blades, but only a few cracks grew all the way across the wall of the hollow core airfoil.
Bone anchors or interference screws? A biomechanical evaluation for autograft ankle stabilization.
Jeys, Lee; Korrosis, Sotiris; Stewart, Todd; Harris, Nicholas J
2004-01-01
Autograft stabilization uses free semitendinosus tendon grafts to anatomically reconstruct the anterior talofibular ligament. Study aims were to evaluate the biomechanical properties of Mitek GII anchors compared with the Arthrex Bio-Tenodesis Screw for free tendon reconstruction of the anterior talofibular ligament. There are no differences in load to failure and percentage specimen elongation at failure between the 2 methods. Controlled laboratory study using porcine models. Sixty porcine tendon constructs were failure tested. Re-creating the pull of the anterior talofibular ligament, loads were applied at 70 degrees to the bones. Thirty-six tendons were fixed to porcine tali and tested using a single pull to failure; 10 were secured with anchors and No. 2 Ethibond, 10 with anchors and FiberWire, 10 with screws and Fiberwire, and 6 with partially gripped screws. Cyclic preloading was conducted on 6 tendons fixed by anchors and on 6 tendons fixed by screws before failure testing. Two groups of 6 components fixed to the fibula were also tested. The talus single-pull anchor group produced a mean load of 114 N and elongation of 37% at failure. The talus single-pull screw group produced a mean load of 227 N and elongation of 22% at failure (P <.05). Cyclic preloading at 65% failure load before failure testing produced increases in load and decreases in elongation at failure. Partially gripped screws produced a load of 133 N and elongation of 30% at failure. The fibula model produced significant increases in load to failure for both. The human anterior talofibular ligament has loads of 139 N at failure with instability occurring at 20% elongation. Interference screw fixation produced significantly greater failure strength and less elongation at failure than bone anchors. The improved biomechanics of interference screws suggests that these may be more suited to in vivo reconstruction of the anterior talofibular ligament than are bone anchors.
Greene, Stephen J; Epstein, Stephen E; Kim, Raymond J; Quyyumi, Arshed A; Cole, Robert T; Anderson, Allen S; Wilcox, Jane E; Skopicki, Hal A; Sikora, Sergey; Verkh, Lev; Tankovich, Nikolai I; Gheorghiade, Mihai; Butler, Javed
2017-04-01
This article describes an ongoing study investigating the safety and efficacy of ischemia-tolerant mesenchymal stem cell (MSC) therapy in patients with nonischemic heart failure and dysfunctional viable myocardium without scarring. This study will follow principles of the previously described mechanistic translational-phase concept whereby the effect of the study agent on laboratory and imaging markers of cardiac structure and function will be tested in a small homogenous cohort with the goal to enhance the understanding of the effect of interventions on cardiac remodeling and performance. This single-blind, placebo-controlled, crossover, multicenter, randomized study will assess the safety, tolerability, and preliminary efficacy of a single intravenous (i.v.) dose of allogeneic ischemia-tolerant MSCs in individuals with heart failure of nonischemic cause, ejection fraction 40% or less, and dysfunctional viable myocardium who have been receiving guideline-directed medical therapy. Eligible patients will have no evidence of baseline replacement scarring on delayed-enhancement cardiac magnetic resonance (CMR). Approximately 20 patients will be randomized in a 1 : 1 ratio to receive an i.v. infusion of ischemia-tolerant MSCs or placebo. At 90 days, the two groups will undergo crossover and received the alternative treatment. The primary endpoint is safety, as evaluated through at least 1-year post-MSC infusion. Additional efficacy endpoints will include measures of cardiac structure and function, as evaluated by serial cine-CMR and transthoracic echocardiography at 90 and 180 days post-initial infusion. This pilot study will explore the safety and effects on cardiac structure and function of i.v. injection of ischemia-tolerant MSCs in a small homogenous cohort of nonischemic heart failure patients with reduced ejection fraction and absent replacement scarring on CMR. This study also represents a prospective mechanistic translational-phase study using baseline and serial CMR imaging in heart failure patients and serves as a potential model for design of future heart failure trials (ClinicalTrials.gov identifier: NCT02467387).
14 CFR 25.629 - Aeroelastic stability requirements.
Code of Federal Regulations, 2010 CFR
2010-01-01
... propeller or rotating device that contributes significant dynamic forces. Compliance with this section must...) Any single failure in any flutter damper system. (3) For airplanes not approved for operation in icing... dynamic forces, any single failure of the engine structure that would reduce the rigidity of the...
Falls, Roman; Seman, Michael; Braat, Sabine; Sortino, Joshua; Allen, Jason D; Neil, Christopher J
2017-08-08
Acute heart failure (AHF) is a frequent reason for hospitalization worldwide and effective treatment options are limited. It is known that AHF is a condition characterized by impaired vasorelaxation, together with reduced nitric oxide (NO) bioavailability, an endogenous vasodilatory compound. Supplementation of inorganic sodium nitrate (NaNO 3 ) is an indirect dietary source of NO, through bioconversion. It is proposed that oral sodium nitrate will favorably affect levels of circulating NO precursors (nitrate and nitrite) in AHF patients, resulting in reduced systemic vascular resistance, without significant hypotension. We propose a single center, randomized, double-blind, placebo-controlled pilot trial, evaluating the feasibility of sodium nitrate as a treatment for AHF. The primary hypothesis that sodium nitrate treatment will result in increased systemic levels of nitric oxide pre-cursors (nitrate and nitrite) in plasma, in parallel with improved vasorelaxation, as assessed by non-invasively derived systemic vascular resistance index. Additional surrogate measures relevant to the known pathophysiology of AHF will be obtained in order to assess clinical effect on dyspnea and renal function. The results of this study will provide evidence of the feasibility of this novel approach and will be of interest to the heart failure community. This trial may inform a larger study.
Triggering Mechanism for Neutron Induced Single-Event Burnout in Power Devices
NASA Astrophysics Data System (ADS)
Shoji, Tomoyuki; Nishida, Shuichi; Hamada, Kimimori
2013-04-01
Cosmic ray neutrons can trigger catastrophic failures in power devices. It has been reported that parasitic transistor action causes single-event burnout (SEB) in power metal-oxide-semiconductor field-effect transistors (MOSFETs) and insulated gate bipolar transistors (IGBTs). However, power diodes do not have an inherent parasitic transistor. In this paper, we describe the mechanism triggering SEB in power diodes for the first time using transient device simulation. Initially, generated electron-hole pairs created by incident recoil ions generate transient current, which increases the electron density in the vicinity of the n-/n+ boundary. The space charge effect of the carriers leads to an increase in the strength of the electric field at the n-/n+ boundary. Finally, the onset of impact ionization at the n-/n+ boundary can trigger SEB. Furthermore, this failure is closely related to diode secondary breakdown. It was clarified that the impact ionization at the n-/n+ boundary is a key point of the mechanism triggering SEB in power devices.
Surgical outcomes analysis of pediatric peritoneal dialysis catheter function in a rural region.
Stone, Matthew L; LaPar, Damien J; Barcia, John P; Norwood, Victoria F; Mulloy, Daniel P; McGahren, Eugene D; Rodgers, Bradley M; Kane, Bartholomew J
2013-07-01
The purpose of this study was to analyze the experience with peritoneal dialysis (PD) at a high-volume, single center institution that supports a rural population. From 2000 to 2010, 88 children (median age: 1.98 years, [range: 2 days-20.2 years]) received 134 PD catheters for the management of acute and chronic renal failure. The primary outcome of interest was the incidence of primary PD catheter failure (replacement or revision within 60 days). Operative technique, longitudinal outcomes, and time intervals to transplantation were analyzed. Median time to transplant from the institution of dialysis was 1.4 years [range: 0.3-6.4 years]. Primary catheter failure occurred in 24.6% of cases. Infants less than 6 months of age demonstrated an increased incidence of primary catheter failure (p = 0.02). The operative technique for catheter placement was not associated with the incidence of primary failure. Postoperative complications included peritonitis (22.7%), omental plugging (11.9%), pericatheter drainage (9.0%), and exit site infection (3.0%). Peritoneal dialysis provides a safe and effective renal replacement therapy for regional pediatric centers that serve a rural population. However, primary catheter failure rates remain high at 24.6%. The surgical technique for placement had no effect on this failure rate in our patient population. Infants less than 6 months of age are at increased risk for primary catheter failure and warrant intensive surveillance. Copyright © 2013. Published by Elsevier Inc.
Probabilistic and Possibilistic Analyses of the Strength of a Bonded Joint
NASA Technical Reports Server (NTRS)
Stroud, W. Jefferson; Krishnamurthy, T.; Smith, Steven A.
2001-01-01
The effects of uncertainties on the strength of a single lap shear joint are explained. Probabilistic and possibilistic methods are used to account for uncertainties. Linear and geometrically nonlinear finite element analyses are used in the studies. To evaluate the strength of the joint, fracture in the adhesive and material strength failure in the strap are considered. The study shows that linear analyses yield conservative predictions for failure loads. The possibilistic approach for treating uncertainties appears to be viable for preliminary design, but with several qualifications.
Dikshit, Vishwesh; Nagalingam, Arun Prasanth; Yap, Yee Ling; Sing, Swee Leong; Yeong, Wai Yee; Wei, Jun
2017-01-01
The objective of this investigation was to determine the quasi-static indentation response and failure mode in three-dimensional (3D) printed trapezoidal core structures, and to characterize the energy absorbed by the structures. In this work, the trapezoidal sandwich structure was designed in the following two ways. Firstly, the trapezoidal core along with its facesheet was 3D printed as a single element comprising a single material for both core and facesheet (type A); Secondly, the trapezoidal core along with facesheet was 3D printed, but with variation in facesheet materials (type B). Quasi-static indentation was carried out using three different indenters, namely standard hemispherical, conical, and flat indenters. Acoustic emission (AE) technique was used to capture brittle cracking in the specimens during indentation. The major failure modes were found to be brittle failure and quasi-brittle fractures. The measured indentation energy was at a maximum when using a conical indenter at 9.40 J and 9.66 J and was at a minimum when using a hemispherical indenter at 6.87 J and 8.82 J for type A and type B series specimens respectively. The observed maximum indenter displacements at failure were the effect of material variations and composite configurations in the facesheet. PMID:28772649
Dikshit, Vishwesh; Nagalingam, Arun Prasanth; Yap, Yee Ling; Sing, Swee Leong; Yeong, Wai Yee; Wei, Jun
2017-03-14
The objective of this investigation was to determine the quasi-static indentation response and failure mode in three-dimensional (3D) printed trapezoidal core structures, and to characterize the energy absorbed by the structures. In this work, the trapezoidal sandwich structure was designed in the following two ways. Firstly, the trapezoidal core along with its facesheet was 3D printed as a single element comprising a single material for both core and facesheet (type A); Secondly, the trapezoidal core along with facesheet was 3D printed, but with variation in facesheet materials (type B). Quasi-static indentation was carried out using three different indenters, namely standard hemispherical, conical, and flat indenters. Acoustic emission (AE) technique was used to capture brittle cracking in the specimens during indentation. The major failure modes were found to be brittle failure and quasi-brittle fractures. The measured indentation energy was at a maximum when using a conical indenter at 9.40 J and 9.66 J and was at a minimum when using a hemispherical indenter at 6.87 J and 8.82 J for type A and type B series specimens respectively. The observed maximum indenter displacements at failure were the effect of material variations and composite configurations in the facesheet.
Reliability Design for Neutron Induced Single-Event Burnout of IGBT
NASA Astrophysics Data System (ADS)
Shoji, Tomoyuki; Nishida, Shuichi; Ohnishi, Toyokazu; Fujikawa, Touma; Nose, Noboru; Hamada, Kimimori; Ishiko, Masayasu
Single-event burnout (SEB) caused by cosmic ray neutrons leads to catastrophic failures in insulated gate bipolar transistors (IGBTs). It was found experimentally that the incident neutron induced SEB failure rate increases as a function of the applied collector voltage. Moreover, the failure rate increased sharply with an increase in the applied collector voltage when the voltage exceeded a certain threshold value (SEB cutoff voltage). In this paper, transient device simulation results indicate that impact ionization at the n-drift/n+ buffer boundary is a crucially important factor in the turning-on of the parasitic pnp transistor, and eventually latch-up of the parasitic thyristor causes SEB. In addition, the device parameter dependency of the SEB cutoff voltage was analytically derived from the latch-up condition of the parasitic thyristor. As a result, it was confirmed that reducing the current gain of the parasitic transistor, such as by increasing the n-drift region thickness d was effective in increasing the SEB cutoff voltage. Furthermore, `white' neutron-irradiation experiments demonstrated that suppressing the inherent parasitic thyristor action leads to an improvement of the SEB cutoff voltage. It was confirmed that current gain optimization of the parasitic transistor is a crucial factor for establishing highly reliable design against chance failures.
14 CFR 31.19 - Performance: Uncontrolled descent.
Code of Federal Regulations, 2010 CFR
2010-01-01
... single failure of the heater assembly, fuel cell system, gas value system, or maneuvering vent system, or from any single tear in the balloon envelope between tear stoppers: (1) The maximum vertical velocity attained. (2) The altitude loss from the point of failure to the point at which maximum vertical velocity...
Masini, Laura; Donis, Laura; Loi, Gianfranco; Mones, Eleonora; Molina, Elisa; Bolchini, Cesare; Krengli, Marco
2014-01-01
The aim of this study was to analyze the application of the failure modes and effects analysis (FMEA) to intracranial stereotactic radiation surgery (SRS) by linear accelerator in order to identify the potential failure modes in the process tree and adopt appropriate safety measures to prevent adverse events (AEs) and near-misses, thus improving the process quality. A working group was set up to perform FMEA for intracranial SRS in the framework of a quality assurance program. FMEA was performed in 4 consecutive tasks: (1) creation of a visual map of the process; (2) identification of possible failure modes; (3) assignment of a risk probability number (RPN) to each failure mode based on tabulated scores of severity, frequency of occurrence and detectability; and (4) identification of preventive measures to minimize the risk of occurrence. The whole SRS procedure was subdivided into 73 single steps; 116 total possible failure modes were identified and a score of severity, occurrence, and detectability was assigned to each. Based on these scores, RPN was calculated for each failure mode thus obtaining values from 1 to 180. In our analysis, 112/116 (96.6%) RPN values were <60, 2 (1.7%) between 60 and 125 (63, 70), and 2 (1.7%) >125 (135, 180). The 2 highest RPN scores were assigned to the risk of using the wrong collimator's size and incorrect coordinates on the laser target localizer frame. Failure modes and effects analysis is a simple and practical proactive tool for systematic analysis of risks in radiation therapy. In our experience of SRS, FMEA led to the adoption of major changes in various steps of the SRS procedure.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Paulson, O.B.; Jarden, J.O.; Godtfredsen, J.
The effect of captopril on cerebral blood flow was studied in five patients with severe congestive heart failure and in five control subjects. Cerebral blood flow was measured by inhalation of /sup 133/xenon and registration of its uptake and washout from the brain by single photon emission computer tomography. In addition, cerebral (internal jugular) venous oxygen tension was determined in the controls. The measurements were made before and 15, 60, and 180 minutes after a single oral dose of captopril (6.25 mg in patients with congestive heart failure and 25 mg in controls). Despite a marked decrease in blood pressure,more » cerebral blood flow increased slightly in the patients with severe congestive heart failure. When a correction was applied to take account of a change in arterial carbon dioxide tension, however, cerebral blood flow was unchanged after captopril administration even in patients with the greatest decrease in blood pressure, in whom a decrease in cerebral blood flow might have been expected. In the controls, blood pressure was little affected by captopril, whereas a slight, but not statistically significant, decrease in cerebral blood flow was observed. The cerebral venous oxygen tension decreased concomitantly.« less
Stable tearing behavior of a thin-sheet material with multiple cracks
NASA Technical Reports Server (NTRS)
Dawicke, D. S.; Newman, J. C., Jr.; Sutton, M. A.; Amstutz, B. E.
1994-01-01
Fracture tests were conducted on 2.3mm thick, 305mm wide sheets of 2024-T3 aluminum alloy with 1-5 collinear cracks. The cracks were introduced (crack history) into the specimens by three methods: (1) saw cutting; (2) fatigue precracking at a low stress range; and (3) fatigue precracking at a high stress range. For the single crack tests, the initial crack history influenced the stress required for the onset of stable crack growth and the first 10mm of crack growth. The effect on failure stress was about 4 percent or less. For the multiple crack tests, the initial crack history was shown to cause differences of more than 20 percent in the link-up stress and 13 percent in failure stress. An elastic-plastic finite element analysis employing the Crack Tip Opening Angle (CTOA) fracture criterion was used to predict the fracture behavior of the single and multiple crack tests. The numerical predictions were within 7 percent of the observed link-up and failure stress in all the tests.
NASA Technical Reports Server (NTRS)
Dawicke, D. S.; Newman, J. C., Jr.; Sutton, M. A.; Amstutz, B. E.
1994-01-01
Fracture tests were conducted on 2.3mm thick, 305mm wide sheets of 2024-T3 aluminum alloy with from one to five collinear cracks. The cracks were introduced (crack history) into the specimens by three methods: saw cutting, fatigue precracking at a low stress range, and fatigue precracking at a high stress range. For the single crack tests, the initial crack history influenced the stress required for the onset of stable crack growth and the first 10mm of crack growth. The effect on failure stress was about 4 percent or less. For the multiple crack tests, the initial crack history was shown to cause differences of more than 20 percent in the link-up stress and 13 percent in failure stress. An elastic-plastic finite element analysis employing the CTOA fracture criterion was used to predict the fracture behavior of the single and multiple crack tests. The numerical predictions were within 7 percent of the observed link-up and failure stress in all the tests.
Zheng, Sean Lee; Chan, Fiona T; Nabeebaccus, Adam A; Shah, Ajay M; McDonagh, Theresa; Okonko, Darlington O; Ayis, Salma
2018-01-01
Background Clinical drug trials in patients with heart failure and preserved ejection fraction have failed to demonstrate improvements in mortality. Methods We systematically searched Medline, Embase and the Cochrane Central Register of Controlled Trials for randomised controlled trials (RCT) assessing pharmacological treatments in patients with heart failure with left ventricular (LV) ejection fraction≥40% from January 1996 to May 2016. The primary efficacy outcome was all-cause mortality. Secondary outcomes were cardiovascular mortality, heart failure hospitalisation, exercise capacity (6-min walk distance, exercise duration, VO2 max), quality of life and biomarkers (B-type natriuretic peptide, N-terminal pro-B-type natriuretic peptide). Random-effects models were used to estimate pooled relative risks (RR) for the binary outcomes, and weighted mean differences for continuous outcomes, with 95% CI. Results We included data from 25 RCTs comprising data for 18101 patients. All-cause mortality was reduced with beta-blocker therapy compared with placebo (RR: 0.78, 95%CI 0.65 to 0.94, p=0.008). There was no effect seen with ACE inhibitors, aldosterone receptor blockers, mineralocorticoid receptor antagonists and other drug classes, compared with placebo. Similar results were observed for cardiovascular mortality. No single drug class reduced heart failure hospitalisation compared with placebo. Conclusion The efficacy of treatments in patients with heart failure and an LV ejection fraction≥40% differ depending on the type of therapy, with beta-blockers demonstrating reductions in all-cause and cardiovascular mortality. Further trials are warranted to confirm treatment effects of beta-blockers in this patient group. PMID:28780577
Failure detection and correction for turbofan engines
NASA Technical Reports Server (NTRS)
Corley, R. C.; Spang, H. A., III
1977-01-01
In this paper, a failure detection and correction strategy for turbofan engines is discussed. This strategy allows continuing control of the engines in the event of a sensor failure. An extended Kalman filter is used to provide the best estimate of the state of the engine based on currently available sensor outputs. Should a sensor failure occur the control is based on the best estimate rather than the sensor output. The extended Kalman filter consists of essentially two parts, a nonlinear model of the engine and up-date logic which causes the model to track the actual engine. Details on the model and up-date logic are presented. To allow implementation, approximations are made to the feedback gain matrix which result in a single feedback matrix which is suitable for use over the entire flight envelope. The effect of these approximations on stability and response is discussed. Results from a detailed nonlinear simulation indicate that good control can be maintained even under multiple failures.
Investigation of precipitate refinement in Mg alloys by an analytical composite failure model
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tabei, Ali; Li, Dongsheng; Lavender, Curt A.
2015-10-01
An analytical model is developed to simulate precipitate refinement in second phase strengthened magnesium alloys. The model is developed based on determination of the stress fields inside elliptical precipitates embedded in a rate dependent inelastic matrix. The stress fields are utilized to determine the failure mode that governs the refinement behavior. Using an AZ31 Mg alloy as an example, the effects the applied load, aspect ratio and orientation of the particle is studied on the macroscopic failure of a single α-Mg17Al12 precipitate. Additionally, a temperature dependent version of the corresponding constitutive law is used to incorporate the effects of temperature.more » In plane strain compression, an extensional failure mode always fragments the precipitates. The critical strain rate at which the precipitates start to fail strongly depends on the orientation of the precipitate with respect to loading direction. The results show that the higher the aspect ratio is, the easier the precipitate fractures. Precipitate shape is another factor influencing the failure response. In contrast to elliptical precipitates with high aspect ratio, spherical precipitates are strongly resistant to sectioning. In pure shear loading, in addition to the extensional mode of precipitate failure, a shearing mode may get activated depending on orientation and aspect ratio of the precipitate. The effect of temperature in relation to strain rate was also verified for plane strain compression and pure shear loading cases.« less
Liang, Wei-Cheng; Liang, Pu-Ping; Wong, Cheuk-Wa; Ng, Tzi-Bun; Huang, Jun-Jiu; Zhang, Jin-Fang; Waye, Mary Miu-Yee; Fu, Wei-Ming
2017-03-01
Fulminant hepatic failure is a life-threatening disease which occurs in patients without preexisting liver disease. Nowadays, there is no ideal therapeutic tool in the treatment of fulminant hepatic failure. Recent studies suggested that a novel technology termed CRISPR/Cas9 may be a promising approach for the treatment of fulminant hepatic failure. In this project, we have designed single chimeric guide RNAs specifically targeting the genomic regions of mouse Fas gene. The in vitro and in vivo effects of sgRNAs on the production of Fas protein were examined in cultured mouse cells and in a hydrodynamic injection-based mouse model, respectively. The in vivo delivery of CRISPR/Cas9 could maintain liver homeostasis and protect hepatocytes from Fas-mediated cell apoptosis in the fulminant hepatic failure model. Our study indicates the clinical potential of developing the CRISPR/Cas9 system as a novel therapeutic strategy to rescue Concanavalin-A-induced fulminant hepatic failure in the mouse model. J. Cell. Biochem. 118: 530-536, 2017. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
Nanostructured 2D cellular materials in silicon by sidewall transfer lithography NEMS
NASA Astrophysics Data System (ADS)
Syms, Richard R. A.; Liu, Dixi; Ahmad, Munir M.
2017-07-01
Sidewall transfer lithography (STL) is demonstrated as a method for parallel fabrication of 2D nanostructured cellular solids in single-crystal silicon. The linear mechanical properties of four lattices (perfect and defected diamond; singly and doubly periodic honeycomb) with low effective Young’s moduli and effective Poisson’s ratio ranging from positive to negative are modelled using analytic theory and the matrix stiffness method with an emphasis on boundary effects. The lattices are fabricated with a minimum feature size of 100 nm and an aspect ratio of 40:1 using single- and double-level STL and deep reactive ion etching of bonded silicon-on-insulator. Nanoelectromechanical systems (NEMS) containing cellular materials are used to demonstrate stretching, bending and brittle fracture. Predicted edge effects are observed, theoretical values of Poisson’s ratio are verified and failure patterns are described.
Instrument and spacecraft faults associated with nuclear radiation in space
NASA Technical Reports Server (NTRS)
Trainos, J. H.
1994-01-01
A review is given which surveys the variety of faults and failures which have occurred in space due both to the effects of single, energetic nuclear particles, as well as effects due to the accumulated ionizing dose or the fluence of nuclear particles. The review covers a variety of problems with sensors, electronics, instruments and spacecraft from several countries.
Stringer, Jeffrey S. A.; McConnell, Michelle S.; Kiarie, James; Bolu, Omotayo; Anekthananon, Thanomsak; Jariyasethpong, Tavatchai; Potter, Dara; Mutsotso, Winnie; Borkowf, Craig B.; Mbori-Ngacha, Dorothy; Muiruri, Peter; Ong'ech, John Odero; Zulu, Isaac; Njobvu, Lungowe; Jetsawang, Bongkoch; Pathak, Sonal; Bulterys, Marc; Shaffer, Nathan; Weidle, Paul J.
2010-01-01
Background Intrapartum and neonatal single-dose nevirapine (NVP) reduces the risk of mother-to-child HIV transmission but also induces viral resistance to non-nucleoside reverse transcriptase inhibitor (NNRTI) drugs. This drug resistance largely fades over time. We hypothesized that women with a prior single-dose NVP exposure would have no more than a 10% higher cumulative prevalence of failure of their NNRTI-containing antiretroviral therapy (ART) over the first 48 wk of therapy than would women without a prior exposure. Methods and Findings We enrolled 355 NVP-exposed and 523 NVP-unexposed women at two sites in Zambia, one site in Kenya, and two sites in Thailand into a prospective, non-inferiority cohort study and followed them for 48 wk on ART. Those who died, discontinued NNRTI-containing ART, or had a plasma viral load ≥400 copies/ml at either the 24 wk or 48 wk study visits and confirmed on repeat testing were characterized as having failed therapy. Overall, 114 of 355 NVP-exposed women (32.1%) and 132 of 523 NVP-unexposed women (25.2%) met criteria for treatment failure. The difference in failure rates between the exposure groups was 6.9% (95% confidence interval [CI] 0.8%–13.0%). The failure rates of women stratified by our predefined exposure interval categories were as follows: 47 of 116 women in whom less than 6 mo elapsed between exposure and starting ART failed therapy (40%; p<0.001 compared to unexposed women); 25 of 67 women in whom 7–12 mo elapsed between exposure and starting ART failed therapy (37%; p = 0.04 compared to unexposed women); and 42 of 172 women in whom more than 12 mo elapsed between exposure and starting ART failed therapy (24%; p = 0.82 compared to unexposed women). Locally weighted regression analysis also indicated a clear inverse relationship between virologic failure and the exposure interval. Conclusions Prior exposure to single-dose NVP was associated with an increased risk of treatment failure; however, this risk seems largely confined to women with a more recent exposure. Women requiring ART within 12 mo of NVP exposure should not be prescribed an NNRTI-containing regimen as first-line therapy. Please see later in the article for the Editors' Summary PMID:20169113
Noble, R T; Moore, D F; Leecaster, M K; McGee, C D; Weisberg, S B
2003-04-01
In July 1999, California's ocean recreational bacterial water quality standards were changed from a total coliform (TC) test to a standard requiring testing for all three bacterial indicators: TC, fecal coliforms (FC), and enterococci (EC). To compare the relationship between the bacterial indicators, and the effect that changing the standards would have on recreational water regulatory actions, three regional studies were conducted along the southern California shoreline from Santa Barbara to San Diego, California. Two studies were conducted during dry weather and one following a large storm event. In each study, samples were collected at over 200 sites which were selected using a stratified random design, with strata consisting of open beach areas and rocky shoreline, and areas near freshwater outlets that drain land-based runoff. During the dry weather studies, samples were collected once per week for 5 weeks. For the storm event study, sampling occurred on a single day about 24 h following the storm. The three indicator bacteria were measured at each site and the results were compared to the single sample standards (TC > 10,000; FC > 400 and EC > 104 MPN or cfu/100 ml). EC was the indicator that failed the single sample standards most often. During the wet weather study, 99% of all standard failures were detected using EC, compared with only 56% for FC, and 40% for TC. During the Summer Study, EC was again the indicator that failed the single sample standards most often, with 60% of the failures for EC alone. The increased failure of the EC standard occurred consistently regardless of whether the sample was collected at a beach or rocky shoreline site, or at a site near a freshwater outlet. Agreement among indicators was better during wet weather than during dry weather. During dry weather, agreement among indicators was better near freshwater outlets than along open shoreline. Cumulatively, our results suggest that replacement of a TC standard with an EC standard will lead to a five-fold increase in failures during dry weather and a doubling of failures during wet weather. Replacing a TC standard with one based on all three indicators will lead to an eight-fold increase in failures. Changes in the requirements for water quality testing have strong implications for increases in beach closures and restrictions. Copyright 2002 Elsevier Science Ltd.
MacDonald, K S; Cameron, D W; D'Costa, L; Ndinya-Achola, J O; Plummer, F A; Ronald, A R
1989-01-01
Chancroid is gaining importance as a sexually transmitted disease because of its association with transmission of human immunodeficiency virus type 1 (HIV-1). Effective, simply administered therapy for chancroid is necessary. Fleroxacin is effective against Haemophilus ducreyi in vitro. We performed an initial randomized clinical trial to assess the efficacy of fleroxacin for treatment of chancroid in Nairobi, Kenya. Fifty-three men with culture-positive chancroid were randomly assigned to receive either 200 mg (group 1) or 400 mg (group 2) of fleroxacin as a single oral dose. Groups 1 and 2 were similar with regard to severity of disease, bubo formation, and HIV-1 status. A satisfactory clinical response to therapy was noted in 23 of 26 patients (88%) in group 1 and 18 of 23 patients (78%) in group 2. Bacteriological failure occurred in 1 of 26 evaluable patients (4%) in group 1 and 4 of 23 evaluable patients (17%) in group 2. Two of 37 HIV-1-seronegative men (5%) and 3 of 11 HIV-1-infected men (27%) were bacteriological failures. Fleroxacin, 200 or 400 mg as a single oral dose, is efficacious therapy for microbiologically proven chancroid in patients who do not have concurrent HIV-1 infection. Among HIV-1-infected men, a single dose of 200 or 400 mg of fleroxacin is inadequate therapy for chancroid. PMID:2502065
Patient Characteristics Predicting Readmission Among Individuals Hospitalized for Heart Failure.
O'Connor, Melissa; Murtaugh, Christopher M; Shah, Shivani; Barrón-Vaya, Yolanda; Bowles, Kathryn H; Peng, Timothy R; Zhu, Carolyn W; Feldman, Penny H
2016-02-01
Heart failure is difficult to manage and increasingly common with many individuals experiencing frequent hospitalizations. Little is known about patient factors consistently associated with hospital readmission. A literature review was conducted to identify heart failure patient characteristics, measured before discharge, that contribute to variation in hospital readmission rates. Database searches yielded 950 potential articles, of which 34 studies met inclusion criteria. Patient characteristics generally have a very modest effect on all-cause or heart failure-related readmission within 7 to 180 days of index hospital discharge. A range of cardiac diseases and other comorbidities only minimally increase readmission rates. No single patient characteristic stands out as a key contributor across multiple studies underscoring the challenge of developing successful interventions to reduce readmissions. Interventions may need to be general in design with the specific intervention depending on each patient's unique clinical profile. © The Author(s) 2015.
Premji, Z.; Makwaya, C.; Minjas, J. N.
1999-01-01
Reported is the use of a 14-day WHO protocol, which takes into account the clinical, parasitological and haematological responses to antimalarial drugs, to determine the efficacy of chloroquine in the treatment of uncomplicated malaria in young children (n = 200) in urban Dar es Salaam. Chloroquine failure was found in 43% of the children. Of these, 12.5% were considered to be early treatment failures and were given a single dose of sulfadoxine-pyrimethamine. Fever subsided in all children treated with sulfadoxine-pyrimethamine and there were no parasitological failures. In addition, children treated with sulfadoxine-pyrimethamine because of early treatment failure with chloroquine had better haematological recovery than the chloroquine-sensitive group. It is concluded that chloroquine can no longer be considered an effective therapy for P. falciparum malaria in young children in Dar es Salaam. PMID:10534897
Unbiased multi-fidelity estimate of failure probability of a free plane jet
NASA Astrophysics Data System (ADS)
Marques, Alexandre; Kramer, Boris; Willcox, Karen; Peherstorfer, Benjamin
2017-11-01
Estimating failure probability related to fluid flows is a challenge because it requires a large number of evaluations of expensive models. We address this challenge by leveraging multiple low fidelity models of the flow dynamics to create an optimal unbiased estimator. In particular, we investigate the effects of uncertain inlet conditions in the width of a free plane jet. We classify a condition as failure when the corresponding jet width is below a small threshold, such that failure is a rare event (failure probability is smaller than 0.001). We estimate failure probability by combining the frameworks of multi-fidelity importance sampling and optimal fusion of estimators. Multi-fidelity importance sampling uses a low fidelity model to explore the parameter space and create a biasing distribution. An unbiased estimate is then computed with a relatively small number of evaluations of the high fidelity model. In the presence of multiple low fidelity models, this framework offers multiple competing estimators. Optimal fusion combines all competing estimators into a single estimator with minimal variance. We show that this combined framework can significantly reduce the cost of estimating failure probabilities, and thus can have a large impact in fluid flow applications. This work was funded by DARPA.
Autonomous control system reconfiguration for spacecraft with non-redundant actuators
NASA Astrophysics Data System (ADS)
Grossman, Walter
1995-05-01
The Small Satellite Technology Initiative (SSTI) 'CLARK' spacecraft is required to be single-failure tolerant, i.e., no failure of any single component or subsystem shall result in complete mission loss. Fault tolerance is usually achieved by implementing redundant subsystems. Fault tolerant systems are therefore heavier and cost more to build and launch than non-redundent, non fault-tolerant spacecraft. The SSTI CLARK satellite Attitude Determination and Control System (ADACS) achieves single-fault tolerance without redundancy. The attitude determination system system uses a Kalman Filter which is inherently robust to loss of any single attitude sensor. The attitude control system uses three orthogonal reaction wheels for attitude control and three magnetic dipoles for momentum control. The nominal six-actuator control system functions by projecting the attitude correction torque onto the reaction wheels while a slower momentum management outer loop removes the excess momentum in the direction normal to the local B field. The actuators are not redundant so the nominal control law cannot be implemented in the event of a loss of a single actuator (dipole or reaction wheel). The spacecraft dynamical state (attitude, angular rate, and momentum) is controllable from any five-element subset of the six actuators. With loss of an actuator the instantaneous control authority may not span R(3) but the controllability gramian integral(limits between t,0) Phi(t, tau)B(tau )B(prime)(tau) Phi(prime)(t, tau)d tau retains full rank. Upon detection of an actuator failure the control torque is decomposed onto the remaining active axes. The attitude control torque is effected and the over-orbit momentum is controlled. The resulting control system performance approaches that of the nominal system.
Gilks, Charles F; Walker, A Sarah; Munderi, Paula; Kityo, Cissy; Reid, Andrew; Katabira, Elly; Goodall, Ruth L; Grosskurth, Heiner; Mugyenyi, Peter; Hakim, James; Gibb, Diana M
2013-01-01
In low-income countries, viral load (VL) monitoring of antiretroviral therapy (ART) is rarely available in the public sector for HIV-infected adults or children. Using clinical failure alone to identify first-line ART failure and trigger regimen switch may result in unnecessary use of costly second-line therapy. Our objective was to identify CD4 threshold values to confirm clinically-determined ART failure when VL is unavailable. 3316 HIV-infected Ugandan/Zimbabwean adults were randomised to first-line ART with Clinically-Driven (CDM, CD4s measured but blinded) or routine Laboratory and Clinical Monitoring (LCM, 12-weekly CD4s) in the DART trial. CD4 at switch and ART failure criteria (new/recurrent WHO 4, single/multiple WHO 3 event; LCM: CD4<100 cells/mm(3)) were reviewed in 361 LCM, 314 CDM participants who switched over median 5 years follow-up. Retrospective VLs were available in 368 (55%) participants. Overall, 265/361 (73%) LCM participants failed with CD4<100 cells/mm(3); only 7 (2%) switched with CD4≥250 cells/mm(3), four switches triggered by WHO events. Without CD4 monitoring, 207/314 (66%) CDM participants failed with WHO 4 events, and 77(25%)/30(10%) with single/multiple WHO 3 events. Failure/switching with single WHO 3 events was more likely with CD4≥250 cells/mm(3) (28/77; 36%) (p = 0.0002). CD4 monitoring reduced switching with viral suppression: 23/187 (12%) LCM versus 49/181 (27%) CDM had VL<400 copies/ml at failure/switch (p<0.0001). Amongst CDM participants with CD4<250 cells/mm(3) only 11/133 (8%) had VL<400 copies/ml, compared with 38/48 (79%) with CD4≥250 cells/mm(3) (p<0.0001). Multiple, but not single, WHO 3 events predicted first-line ART failure. A CD4 threshold 'tiebreaker' of ≥250 cells/mm(3) for clinically-monitored patients failing first-line could identify ∼80% with VL<400 copies/ml, who are unlikely to benefit from second-line. Targeting CD4s to single WHO stage 3 'clinical failures' would particularly avoid premature, costly switch to second-line ART.
Effects of Sentence Context on Lexical Ambiguity Resolution in Patients with Schizophrenia
ERIC Educational Resources Information Center
Andreou, Christina; Tsapkini, Kyrana; Bozikas, Vasilis P.; Giannakou, Maria; Karavatos, Athanasios; Nimatoudis, Ioannis
2009-01-01
Previous research has suggested that a failure in processing contextual information may account for the heterogeneous clinical manifestations and cognitive impairments observed in schizophrenia. In the domain of language, context processing in schizophrenia has been investigated mostly with single-word semantic priming paradigms; however, natural…
Exposure to particulate matter (PM) air pollution results in airways hyperresponsiveness (AHR), however it also results in adverse cardiovascular effects, particularly in individuals with underlying cardiovascular disease. The impact of pre-existing cardiac deficit on PM-induced ...
14 CFR 35.15 - Safety analysis.
Code of Federal Regulations, 2014 CFR
2014-01-01
... combined with sound design and test philosophies. (b) If significant doubt exists as to the effects of... STANDARDS: PROPELLERS Design and Construction § 35.15 Safety analysis. (a)(1) The applicant must analyze the... to be verified by test. (c) The primary failures of certain single propeller elements (for example...
14 CFR 35.15 - Safety analysis.
Code of Federal Regulations, 2013 CFR
2013-01-01
... combined with sound design and test philosophies. (b) If significant doubt exists as to the effects of... STANDARDS: PROPELLERS Design and Construction § 35.15 Safety analysis. (a)(1) The applicant must analyze the... to be verified by test. (c) The primary failures of certain single elements (for example, blades...
14 CFR 35.15 - Safety analysis.
Code of Federal Regulations, 2012 CFR
2012-01-01
... combined with sound design and test philosophies. (b) If significant doubt exists as to the effects of... STANDARDS: PROPELLERS Design and Construction § 35.15 Safety analysis. (a)(1) The applicant must analyze the... to be verified by test. (c) The primary failures of certain single elements (for example, blades...
14 CFR 35.15 - Safety analysis.
Code of Federal Regulations, 2010 CFR
2010-01-01
... combined with sound design and test philosophies. (b) If significant doubt exists as to the effects of... STANDARDS: PROPELLERS Design and Construction § 35.15 Safety analysis. (a)(1) The applicant must analyze the... to be verified by test. (c) The primary failures of certain single elements (for example, blades...
Single oral dose of 1-5g. talampicillin in the treatment of gonorrhoea.
Willcox, R R
1976-01-01
81 patients have been treated with single oral doses of 1-5 g. (6 tablets) of talampicillin without probenecid. The failure rate amongst those followed was only 4-2 per cent. No side-effects were reported. These results were superior to those obtained with 2-0g. or equivalent of ampicillin, amoxycillin, or pivampicillin with probenecid. Talampicillin is thus the most potent ampicillin-like antibiotic so far available for the treatment of gonorrhoea and is capable of curing the disease with a smaller single dose without probenecid than is necessary for other preparations. PMID:1276866
Fokkinga, Wietske A; Kreulen, Cees M; Vallittu, Pekka K; Creugers, Nico H J
2004-01-01
This study sought to aggregate literature data on in vitro failure loads and failure modes of prefabricated fiber-reinforced composite (FRC) post systems and to compare them to those of prefabricated metal, custom-cast, and ceramic post systems. The literature was searched using MEDLINE from 1984 to 2003 for dental articles in English. Keywords used were (post or core or buildup or dowel) and (teeth or tooth). Additional inclusion/exclusion steps were conducted, each step by two independent readers: (1) Abstracts describing post-and-core techniques to reconstruct endodontically treated teeth and their mechanical and physical characteristics were included (descriptive studies or reviews were excluded); (2) articles that included FRC post systems were selected; (3) in vitro studies, single-rooted human teeth, prefabricated FRC posts, and composite as the core material were the selection criteria; and (4) failure loads and modes were extracted from the selected papers, and failure modes were dichotomized (distinction was made between "favorable failures," defined as reparable failures, and "unfavorable failures,"defined as irreparable [root] fractures). The literature search revealed 1,984 abstracts. Included were 244, 42, and 12 articles in the first, second, and third selection steps, respectively. Custom-cast post systems showed higher failure loads than prefabricated FRC post systems, whereas ceramic showed lower failure loads. Significantly more favorable failures occurred with prefabricated FRC post systems than with prefabricated and custom-cast metal post systems. The variable "post system" had a significant effect on mean failure loads. FRC post systems more frequently showed favorable failure modes than did metal post systems.
NASA Technical Reports Server (NTRS)
Bailey, Randall E.; Kramer, Lynda J.; Kennedy, Kellie D.; Stephens, Chad L.; Etherington, Timothy J.
2017-01-01
Future reduced crew operations or even single pilot operations for commercial airline and on-demand mobility applications are an active area of research. These changes would reduce the human element and thus, threaten the precept that "a well-trained and well-qualified pilot is the critical center point of aircraft systems safety and an integral safety component of the entire commercial aviation system." NASA recently completed a pilot-in-the-loop high fidelity motion simulation study in partnership with the Federal Aviation Administration (FAA) attempting to quantify the pilot's contribution to flight safety during normal flight and in response to aircraft system failures. Crew complement was used as the experiment independent variable in a between-subjects design. These data show significant increases in workload for single pilot operations, compared to two-crew, with subjective assessments of safety and performance being significantly degraded as well. Nonetheless, in all cases, the pilots were able to overcome the failure mode effects in all crew configurations. These data reflect current-day flight deck equipage and help identify the technologies that may improve two-crew operations and/or possibly enable future reduced crew and/or single pilot operations.
Gamell, Marc; Teranishi, Keita; Kolla, Hemanth; ...
2017-10-26
In order to achieve exascale systems, application resilience needs to be addressed. Some programming models, such as task-DAG (directed acyclic graphs) architectures, currently embed resilience features whereas traditional SPMD (single program, multiple data) and message-passing models do not. Since a large part of the community's code base follows the latter models, it is still required to take advantage of application characteristics to minimize the overheads of fault tolerance. To that end, this paper explores how recovering from hard process/node failures in a local manner is a natural approach for certain applications to obtain resilience at lower costs in faulty environments.more » In particular, this paper targets enabling online, semitransparent local recovery for stencil computations on current leadership-class systems as well as presents programming support and scalable runtime mechanisms. Also described and demonstrated in this paper is the effect of failure masking, which allows the effective reduction of impact on total time to solution due to multiple failures. Furthermore, we discuss, implement, and evaluate ghost region expansion and cell-to-rank remapping to increase the probability of failure masking. To conclude, this paper shows the integration of all aforementioned mechanisms with the S3D combustion simulation through an experimental demonstration (using the Titan system) of the ability to tolerate high failure rates (i.e., node failures every five seconds) with low overhead while sustaining performance at large scales. In addition, this demonstration also displays the failure masking probability increase resulting from the combination of both ghost region expansion and cell-to-rank remapping.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gamell, Marc; Teranishi, Keita; Kolla, Hemanth
In order to achieve exascale systems, application resilience needs to be addressed. Some programming models, such as task-DAG (directed acyclic graphs) architectures, currently embed resilience features whereas traditional SPMD (single program, multiple data) and message-passing models do not. Since a large part of the community's code base follows the latter models, it is still required to take advantage of application characteristics to minimize the overheads of fault tolerance. To that end, this paper explores how recovering from hard process/node failures in a local manner is a natural approach for certain applications to obtain resilience at lower costs in faulty environments.more » In particular, this paper targets enabling online, semitransparent local recovery for stencil computations on current leadership-class systems as well as presents programming support and scalable runtime mechanisms. Also described and demonstrated in this paper is the effect of failure masking, which allows the effective reduction of impact on total time to solution due to multiple failures. Furthermore, we discuss, implement, and evaluate ghost region expansion and cell-to-rank remapping to increase the probability of failure masking. To conclude, this paper shows the integration of all aforementioned mechanisms with the S3D combustion simulation through an experimental demonstration (using the Titan system) of the ability to tolerate high failure rates (i.e., node failures every five seconds) with low overhead while sustaining performance at large scales. In addition, this demonstration also displays the failure masking probability increase resulting from the combination of both ghost region expansion and cell-to-rank remapping.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Quinn, Heather; Wirthlin, Michael
A variety of fault emulation systems have been created to study the effect of single-event effects (SEEs) in static random access memory (SRAM) based field-programmable gate arrays (FPGAs). These systems are useful for augmenting radiation-hardness assurance (RHA) methodologies for verifying the effectiveness for mitigation techniques; understanding error signatures and failure modes in FPGAs; and failure rate estimation. For radiation effects researchers, it is important that these systems properly emulate how SEEs manifest in FPGAs. If the fault emulation systems does not mimic the radiation environment, the system will generate erroneous data and incorrect predictions of behavior of the FPGA inmore » a radiation environment. Validation determines whether the emulated faults are reasonable analogs to the radiation-induced faults. In this study we present methods for validating fault emulation systems and provide several examples of validated FPGA fault emulation systems.« less
Common Cause Failures and Ultra Reliability
NASA Technical Reports Server (NTRS)
Jones, Harry W.
2012-01-01
A common cause failure occurs when several failures have the same origin. Common cause failures are either common event failures, where the cause is a single external event, or common mode failures, where two systems fail in the same way for the same reason. Common mode failures can occur at different times because of a design defect or a repeated external event. Common event failures reduce the reliability of on-line redundant systems but not of systems using off-line spare parts. Common mode failures reduce the dependability of systems using off-line spare parts and on-line redundancy.
Neutron-induced single event burnout in high voltage electronics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Normand, E.; Wert, J.L.; Oberg, D.L.
Energetic neutrons with an atmospheric neutron spectrum, which were demonstrated to induce single event burnout in power MOSFETs, have been shown to induce burnout in high voltage (>3,000V) electronics when operated at voltages as low as 50% of rated voltage. The laboratory failure rates correlate well with field failure rates measured in Europe.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-23
... Boeing Model 787-8 airplane will incorporate a fuel tank nitrogen generation system (NGS) that actively... ignition source in the fuel tank system could not result from any single failure, from any single failure... of fuel systems. We do not intend to apply the alternative standards used under these special...
Calcium channel blockers in hypertension. Is there still a controversy?
Izzo, Joseph L
2005-08-01
There are several reasons why no single antihypertensive drug class is ideal in all clinical situations. First, pathophysiologic heterogeneity in hypertension and diversity of mechanisms of antihypertensive drugs dictate that no single drug class can be optimally effective in all subpopulations. Second, sustained blood pressure control generally requires combination therapy to block the reflex stimulation of physiologic mechanisms that attempt to restore blood pressure to pretreatment levels. Third, while effective blood pressure control is more important than choice of initial drug in the prevention of hypertension-related morbidity and mortality, specific drug classes are indicated for optimal treatment of complications of hypertension (e.g. heart failure, kidney disease). Fourth, although antihypertensive drug side effects are uncommon, alternative strategies are required in some patients. Given these principles, past controversies regarding whether calcium channel blockers (CCBs) should be used in the treatment of hypertension become moot. CCBs are extremely effective in lowering blood pressure and in preventing stroke and cardiovascular disease. When additional blood pressure lowering is necessary to meet strict targets, CCBs may be added, even in heart failure or chronic kidney disease, where CCBs alone may not achieve optimal outcomes. Combinations of CCBs with "anti-neurohumoral" drugs such as ACE inhibitors are particularly useful to achieve sustained blood pressure control, reduce adverse effects such as edema, and improve outcomes.
A global analysis approach for investigating structural resilience in urban drainage systems.
Mugume, Seith N; Gomez, Diego E; Fu, Guangtao; Farmani, Raziyeh; Butler, David
2015-09-15
Building resilience in urban drainage systems requires consideration of a wide range of threats that contribute to urban flooding. Existing hydraulic reliability based approaches have focused on quantifying functional failure caused by extreme rainfall or increase in dry weather flows that lead to hydraulic overloading of the system. Such approaches however, do not fully explore the full system failure scenario space due to exclusion of crucial threats such as equipment malfunction, pipe collapse and blockage that can also lead to urban flooding. In this research, a new analytical approach based on global resilience analysis is investigated and applied to systematically evaluate the performance of an urban drainage system when subjected to a wide range of structural failure scenarios resulting from random cumulative link failure. Link failure envelopes, which represent the resulting loss of system functionality (impacts) are determined by computing the upper and lower limits of the simulation results for total flood volume (failure magnitude) and average flood duration (failure duration) at each link failure level. A new resilience index that combines the failure magnitude and duration into a single metric is applied to quantify system residual functionality at each considered link failure level. With this approach, resilience has been tested and characterised for an existing urban drainage system in Kampala city, Uganda. In addition, the effectiveness of potential adaptation strategies in enhancing its resilience to cumulative link failure has been tested. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.
NASA Astrophysics Data System (ADS)
Ahmed, Ammar; Arthur, Craig; Edwards, Mark
2010-06-01
Bulk electricity transmission lines are linear assets that can be very exposed to wind effects, particularly where they traverse steep topography or open coastal terrain in cyclonic regions. Interconnected nature of the lattice type towers and conductors also, present complex vulnerabilities. These relate to the direction of wind attack to the conductors and the cascading failure mechanisms in which the failure of a single tower has cascading effects on neighbouring towers. Such behaviour is exacerbated by the finely tuned nature of tower design which serves to minimize cost and reserve strength at design wind speeds. There is a clear need to better quantify the interdependent vulnerabilities of these critical infrastructure assets in the context of the severe wind hazard. This paper presents a novel methodology developed for the Critical Infrastructure Protection Modelling and Analysis (CIPMA) capability for assessing local wind speeds and the likelihood of tower failure for a range of transmission tower and conductor types. CIPMA is a program managed by the Federal Attorney-General's Department and Geoscience Australia is leading the technical development. The methodology then involves the development of heuristically derived vulnerability models that are consistent with Australian industry experience and full-scale static tower testing results, considering isolated tower loss along with three interdependent failure mechanisms to give overall likelihoods of failure.
Zheng, Sean Lee; Chan, Fiona T; Nabeebaccus, Adam A; Shah, Ajay M; McDonagh, Theresa; Okonko, Darlington O; Ayis, Salma
2018-03-01
Clinical drug trials in patients with heart failure and preserved ejection fraction have failed to demonstrate improvements in mortality. We systematically searched Medline, Embase and the Cochrane Central Register of Controlled Trials for randomised controlled trials (RCT) assessing pharmacological treatments in patients with heart failure with left ventricular (LV) ejection fraction≥40% from January 1996 to May 2016. The primary efficacy outcome was all-cause mortality. Secondary outcomes were cardiovascular mortality, heart failure hospitalisation, exercise capacity (6-min walk distance, exercise duration, VO 2 max), quality of life and biomarkers (B-type natriuretic peptide, N-terminal pro-B-type natriuretic peptide). Random-effects models were used to estimate pooled relative risks (RR) for the binary outcomes, and weighted mean differences for continuous outcomes, with 95% CI. We included data from 25 RCTs comprising data for 18101 patients. All-cause mortality was reduced with beta-blocker therapy compared with placebo (RR: 0.78, 95%CI 0.65 to 0.94, p=0.008). There was no effect seen with ACE inhibitors, aldosterone receptor blockers, mineralocorticoid receptor antagonists and other drug classes, compared with placebo. Similar results were observed for cardiovascular mortality. No single drug class reduced heart failure hospitalisation compared with placebo. The efficacy of treatments in patients with heart failure and an LV ejection fraction≥40% differ depending on the type of therapy, with beta-blockers demonstrating reductions in all-cause and cardiovascular mortality. Further trials are warranted to confirm treatment effects of beta-blockers in this patient group. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Moussawi, A; Derzsy, N; Lin, X; Szymanski, B K; Korniss, G
2017-09-15
Cascading failures are a critical vulnerability of complex information or infrastructure networks. Here we investigate the properties of load-based cascading failures in real and synthetic spatially-embedded network structures, and propose mitigation strategies to reduce the severity of damages caused by such failures. We introduce a stochastic method for optimal heterogeneous distribution of resources (node capacities) subject to a fixed total cost. Additionally, we design and compare the performance of networks with N-stable and (N-1)-stable network-capacity allocations by triggering cascades using various real-world node-attack and node-failure scenarios. We show that failure mitigation through increased node protection can be effectively achieved against single-node failures. However, mitigating against multiple node failures is much more difficult due to the combinatorial increase in possible sets of initially failing nodes. We analyze the robustness of the system with increasing protection, and find that a critical tolerance exists at which the system undergoes a phase transition, and above which the network almost completely survives an attack. Moreover, we show that cascade-size distributions measured in this region exhibit a power-law decay. Finally, we find a strong correlation between cascade sizes induced by individual nodes and sets of nodes. We also show that network topology alone is a weak predictor in determining the progression of cascading failures.
Risk-based planning analysis for a single levee
NASA Astrophysics Data System (ADS)
Hui, Rui; Jachens, Elizabeth; Lund, Jay
2016-04-01
Traditional risk-based analysis for levee planning focuses primarily on overtopping failure. Although many levees fail before overtopping, few planning studies explicitly include intermediate geotechnical failures in flood risk analysis. This study develops a risk-based model for two simplified levee failure modes: overtopping failure and overall intermediate geotechnical failure from through-seepage, determined by the levee cross section represented by levee height and crown width. Overtopping failure is based only on water level and levee height, while through-seepage failure depends on many geotechnical factors as well, mathematically represented here as a function of levee crown width using levee fragility curves developed from professional judgment or analysis. These levee planning decisions are optimized to minimize the annual expected total cost, which sums expected (residual) annual flood damage and annualized construction costs. Applicability of this optimization approach to planning new levees or upgrading existing levees is demonstrated preliminarily for a levee on a small river protecting agricultural land, and a major levee on a large river protecting a more valuable urban area. Optimized results show higher likelihood of intermediate geotechnical failure than overtopping failure. The effects of uncertainty in levee fragility curves, economic damage potential, construction costs, and hydrology (changing climate) are explored. Optimal levee crown width is more sensitive to these uncertainties than height, while the derived general principles and guidelines for risk-based optimal levee planning remain the same.
NASA Technical Reports Server (NTRS)
Vanschalkwyk, Christiaan Mauritz
1991-01-01
Many applications require that a control system must be tolerant to the failure of its components. This is especially true for large space-based systems that must work unattended and with long periods between maintenance. Fault tolerance can be obtained by detecting the failure of the control system component, determining which component has failed, and reconfiguring the system so that the failed component is isolated from the controller. Component failure detection experiments that were conducted on an experimental space structure, the NASA Langley Mini-Mast are presented. Two methodologies for failure detection and isolation (FDI) exist that do not require the specification of failure modes and are applicable to both actuators and sensors. These methods are known as the Failure Detection Filter and the method of Generalized Parity Relations. The latter method was applied to three different sensor types on the Mini-Mast. Failures were simulated in input-output data that were recorded during operation of the Mini-Mast. Both single and double sensor parity relations were tested and the effect of several design parameters on the performance of these relations is discussed. The detection of actuator failures is also treated. It is shown that in all the cases it is possible to identify the parity relations directly from input-output data. Frequency domain analysis is used to explain the behavior of the parity relations.
McNair, Patrick; Jones, Erica; Truong, Quynh; Singh, Harsimran
Single coronary artery is a rare clinical finding. Diagnosis is typically made incidentally after the patient presents with symptoms and undergoes coronary angiography, coronary computed tomography angiography (CTA), or post-mortem during autopsy. Several high-risk features of anomalous coronary arteries have been described in the literature. Our paper describes a case of dilated alcoholic cardiomyopathy presenting as heart failure with diagnostic workup incidentally revealing single coronary artery. Copyright © 2017 Elsevier Inc. All rights reserved.
Long-term single-center experience of defibrillator therapy in children and adolescents.
Frommeyer, Gerrit; Feder, Sebastian; Bettin, Markus; Debus, Volker; Köbe, Julia; Reinke, Florian; Uebing, Anselm; Eckardt, Lars; Kehl, Hans Gerd
2018-06-01
Implantable cardioverter-defibrillator (ICD) systems are established therapy for prevention of sudden cardiac death. Long-term data on ICD systems in children and adolescents is rare. The present study displays a long-term single-center follow-up of children and adolescents with ICD systems. The present study represents a single-center experience of patients younger than 18 years who received an ICD (n = 58). Follow-up data included in-house follow-up as well as examinations of collaborating specialists. Mean age at implantation was 14.0 ± 3.3 years and 33 patients (56.9%) were male. A transvenous ICD system was implanted in 54 patients (93.1%). In 33 patients (56.9%) electrical heart disease or idiopathic ventricular fibrillation represented the underlying condition of ICD implantation. Median follow-up duration was 70 months (45; 94). 3 patients (5.2%) died during the observation period. None of these deaths was associated with ICD failure. Appropriate shocks occurred in 32 patients (55.2%). Inappropriate shock delivery was recorded in 17 patients (29.3%). Supraventricular tachycardia represented the most frequent cause of inappropriate shock delivery (9 patients, 52.9%). T-wave oversensing led to inappropriate shock delivery in 3 patients (17.6%). In 5 patients (29.4%), lead failure caused inappropriate shock delivery. Of note, during follow-up lead failure was reported in 15 patients (25.9%) leading to surgical revision. ICD therapy in children and adolescents is effective for prevention of sudden cardiac death. The rate of appropriate shock deliveries was significantly higher as compared with large ICD trials. Inappropriate therapies occurred frequently. In particular supraventricular tachycardia, T-wave oversensing and lead failures were responsible for these episodes. Copyright © 2017 Elsevier B.V. All rights reserved.
Assessment of maternal smoking status during pregnancy and the associations with neonatal outcomes.
Bakker, Rachel; Kruithof, Claudia; Steegers, Eric A P; Tiemeier, Henning; Mackenbach, Johan P; Hofman, Albert; Jaddoe, Vincent W V
2011-12-01
Single assessment of smoking during pregnancy may lead to misclassification due to underreporting or failure of smoking cessation. We examined the percentage of mothers who were misclassified in smoking status based on single assessment, as compared with repeated assessment, and whether this misclassification leads to altered effect estimates for the associations between maternal smoking and neonatal complications. This study was performed in 5,389 mothers participating in a prospective population-based cohort study in the Netherlands. Smoking status was assessed 3 times during pregnancy using questionnaires. Information on birth weight and neonatal complications was obtained from hospital records. For categorizing mothers per smoking status, Cohen's Kappa coefficient was .86 (p < .001) between single and repeated assessments. Of all mothers who reported nonsmoking or first trimester-only smoking in early pregnancy, 1.7% (70 of 4,141) and 33.7% (217 of 643), respectively, were reclassified to continued smoking based on repeated assessment. Younger, shorter lower educated mothers who had non-European ethnicity experienced more stress, consumed more alcohol, and did not use folic acid supplements had higher risk of underreporting their smoking status or failure of smoking cessation. Marginal differences were found on the associations of maternal smoking with neonatal complications between single or repeated assessment. Our results suggest that single assessment of smoking during pregnancy leads to underestimation of the continued smoking prevalence, especially among mothers who reported quitting smoking in first trimester. However, this underestimation does not materially change the effect estimates for the associations between maternal smoking and neonatal outcomes.
Muscle damage and repeated bout effect following blood flow restricted exercise.
Sieljacks, Peter; Matzon, Andreas; Wernbom, Mathias; Ringgaard, Steffen; Vissing, Kristian; Overgaard, Kristian
2016-03-01
Blood-flow restricted resistance exercise training (BFRE) is suggested to be effective in rehabilitation training, but more knowledge is required about its potential muscle damaging effects. Therefore, we investigated muscle-damaging effects of BFRE performed to failure and possible protective effects of previous bouts of BFRE or maximal eccentric exercise (ECC). Seventeen healthy young men were allocated into two groups completing two exercise bouts separated by 14 days. One group performed BFRE in both exercise bouts (BB). The other group performed ECC in the first and BFRE in the second bout. BFRE was performed to failure. Indicators of muscle damage were evaluated before and after exercise. The first bout in the BB group led to decrements in maximum isometric torque, and increases in muscle soreness, muscle water retention, and serum muscle protein concentrations after exercise. These changes were comparable in magnitude and time course to what was observed after first bout ECC. An attenuated response was observed in the repeated exercise bout in both groups. We conclude that unaccustomed single-bout BFRE performed to failure induces significant muscle damage. Additionally, both ECC and BFRE can precondition against muscle damage induced by a subsequent bout of BFRE.
Work-hardening behaviour of Mg single crystals oriented for basal slip
NASA Astrophysics Data System (ADS)
Bhattacharya, B.; Niewczas, M.
2011-06-01
Work-hardening behaviour of Mg single crystals oriented for basal slip was studied by means of tensile tests carried out at 4, 78 and 295 K. The crystals show critical resolved shear stress values (CRSS) for a {0001} ? basal slip system in the range 1-1.5 MPa. The samples exhibit two-stage work hardening characteristics consisting of a long easy glide stage and a stage of rapid hardening terminated by failure. The onset of the plastic flow up to the point of fracture is accompanied by a low work-hardening rate in the range 5 × 10-5-5 × 10-4 µ, corresponding to the hardening rate in Stage I of copper single crystals. The analysis of thermally activated glide parameters suggests that forest interactions are rate-controlling processes. The very low value of the activation distance found at 4 K, ∼0.047 b, is attributed to zero-point energy effects. The failure of crystals occurs well before their hardening capacity is exhausted by mechanisms which are characteristic of deformation temperature.
NASA Astrophysics Data System (ADS)
Kim, S. Y.; Yoo, J. H.; Kim, H. K.; Shin, K. Y.; Yoon, S. J.
2018-06-01
In this paper, we discussed the structural behavior of bolted lap-joint connections in pultruded FRP structural members. Especially, bolted connections in pultruded FRP members are investigated for their failure modes and strength. Specimens with single and multiple bolt-holes are tested in tension under bolt-loading conditions. All of the specimens are instrumented with strain gages and the load-strain responses are monitored. The failed specimens are examined for the cracks and failure patterns. The purpose of this paper is to predict the failure strength by using the ratio of the results obtained by the experiment and the finite element analysis. In the study, several tests are conducted to determine the mechanical properties of pultruded FRP materials before the main experiment. The results are used in the finite element analysis for single and multiple bolted lap-joint specimens. The results obtained by the experiment are compared with the results obtained by the finite element analysis.
14 CFR 25.775 - Windshields and windows.
Code of Federal Regulations, 2010 CFR
2010-01-01
... differential loads combined with critical aerodynamic pressure and temperature effects after any single failure... front of the pilots must be arranged so that, assuming the loss of vision through any one panel, one or... flight and landing. [Doc. No. 5066, 29 FR 18291, Dec. 24, 1964, as amended by Amdt. 25-23, 35 FR 5676...
14 CFR 25.775 - Windshields and windows.
Code of Federal Regulations, 2013 CFR
2013-01-01
... differential loads combined with critical aerodynamic pressure and temperature effects after any single failure... front of the pilots must be arranged so that, assuming the loss of vision through any one panel, one or... flight and landing. [Doc. No. 5066, 29 FR 18291, Dec. 24, 1964, as amended by Amdt. 25-23, 35 FR 5676...
14 CFR 25.775 - Windshields and windows.
Code of Federal Regulations, 2012 CFR
2012-01-01
... differential loads combined with critical aerodynamic pressure and temperature effects after any single failure... front of the pilots must be arranged so that, assuming the loss of vision through any one panel, one or... flight and landing. [Doc. No. 5066, 29 FR 18291, Dec. 24, 1964, as amended by Amdt. 25-23, 35 FR 5676...
14 CFR 25.775 - Windshields and windows.
Code of Federal Regulations, 2014 CFR
2014-01-01
... differential loads combined with critical aerodynamic pressure and temperature effects after any single failure... front of the pilots must be arranged so that, assuming the loss of vision through any one panel, one or... flight and landing. [Doc. No. 5066, 29 FR 18291, Dec. 24, 1964, as amended by Amdt. 25-23, 35 FR 5676...
14 CFR 25.775 - Windshields and windows.
Code of Federal Regulations, 2011 CFR
2011-01-01
... differential loads combined with critical aerodynamic pressure and temperature effects after any single failure... front of the pilots must be arranged so that, assuming the loss of vision through any one panel, one or... flight and landing. [Doc. No. 5066, 29 FR 18291, Dec. 24, 1964, as amended by Amdt. 25-23, 35 FR 5676...
14 CFR 23.1309 - Equipment, systems, and installations.
Code of Federal Regulations, 2012 CFR
2012-01-01
... of the effect. (2) In a single-engine airplane, must be designed to minimize hazards to the airplane in the event of a probable malfunction or failure. (3) In a multiengine airplane, must be designed to... category airplane, must be designed to safeguard against hazards to the airplane in the event of their...
Quek, H C; Tan, Keson B; Nicholls, Jack I
2008-01-01
Biomechanical load-fatigue performance data on single-tooth implant systems with different implant-abutment interface designs is lacking in the literature. This study evaluated the load fatigue performance of 4 implant-abutment interface designs (Brånemark-CeraOne; 3i Osseotite-STA abutment; Replace Select-Easy abutment; and Lifecore Stage-1-COC abutment system). The number of load cycles to fatigue failure of 4 implant-abutment designs was tested with a custom rotational load fatigue machine. The effect of increasing and decreasing the tightening torque by 20% respectively on the load fatigue performance was also investigated. Three different tightening torque levels (recommended torque, -20% recommended torque, +20% recommended torque) were applied to the 4 implant systems. There were 12 test groups with 5 samples in each group. The rotational load fatigue machine subjected specimens to a sinusoidally applied 35 Ncm bending moment at a test frequency of 14 Hz. The number of cycles to failure was recorded. A cutoff of 5 x 10(6) cycles was applied as an upper limit. There were 2 implant failures and 1 abutment screw failure in the Brånemark group. Five abutment screw failures and 4 implant failures was recorded for the 3i system. The Replace Select system had 1 implant failure. Five cone screw failures were noted for the Lifecore system. Analysis of variance revealed no statistically significant difference in load cycles to failure for the 4 different implant-abutment systems torqued at recommended torque level. A statistically significant difference was found between the -20% torque group and the +20% torque group (P < .05) for the 3i system. Load fatigue performance and failure location is system specific and related to the design characteristics of the implant-abutment combination. It appeared that if the implant-abutment interface was maintained, load fatigue failure would occur at the weakest point of the implant. It is important to use the torque level recommended by the manufacturer.
Chen, Yiyin; Funk, Marjorie; Wen, Jia; Tang, Xianghua; He, Guixiang; Liu, Hong
Multidisciplinary disease management programs (MDMP) for patients with heart failure (HF) have been delivered, but evidence of their effectiveness in China is limited. To determine if a MDMP improves quality of life (QoL), physical performance, depressive symptoms, self-care behaviors and mortality or rehospitalization in patients with HF in China. This is a randomized controlled single center trial in which patients with HF received either MDMP with discharge education, physical training, follow-up visits and telephone calls for 180 days (n = 31) or standard care (SC, n = 31). Compared with SC, QoL, depressive symptoms, and self-care behaviors were significantly improved by MDMP from baseline to 180 days (37% vs 66%, 20% vs 61%, and 8% vs 33%, respectively, all p < 0.001). There were no differences in physical performance and mortality or rehospitalization during follow-up. A HF MDMP can improve QoL, depressive symptoms and self-care behaviors in China. Copyright © 2017 Elsevier Inc. All rights reserved.
McCormick, Norman J.
1976-01-01
For use in the identification of failed fuel assemblies in a nuclear reactor, the ratios of the tag gas isotopic concentrations are located on curved surfaces to enable the ratios corresponding to failure of a single fuel assembly to be distinguished from those formed from any combination of two or more failed assemblies.
Malau-Aduli, Bunmi Sherifat; Teague, Peta-Ann; D'Souza, Karen; Heal, Clare; Turner, Richard; Garne, David L; van der Vleuten, Cees
2017-12-01
A key issue underpinning the usefulness of the OSCE assessment to medical education is standard setting, but the majority of standard-setting methods remain challenging for performance assessment because they produce varying passing marks. Several studies have compared standard-setting methods; however, most of these studies are limited by their experimental scope, or use data on examinee performance at a single OSCE station or from a single medical school. This collaborative study between 10 Australian medical schools investigated the effect of standard-setting methods on OSCE cut scores and failure rates. This research used 5256 examinee scores from seven shared OSCE stations to calculate cut scores and failure rates using two different compromise standard-setting methods, namely the Borderline Regression and Cohen's methods. The results of this study indicate that Cohen's method yields similar outcomes to the Borderline Regression method, particularly for large examinee cohort sizes. However, with lower examinee numbers on a station, the Borderline Regression method resulted in higher cut scores and larger difference margins in the failure rates. Cohen's method yields similar outcomes as the Borderline Regression method and its application for benchmarking purposes and in resource-limited settings is justifiable, particularly with large examinee numbers.
Delamination of Composite Cylinders
NASA Astrophysics Data System (ADS)
Davies, Peter; Carlsson, Leif A.
The delamination resistance of filament wound glass/epoxy cylinders has been characterized for a range of winding angles and fracture mode ratios using beam fracture specimens. The results reveal that the delamination fracture resistance increases with increasing winding angle and mode II (shear) fraction (GΠ/G). It was also found that interlaced fiber bundles in the filament wound cylinder wall acted as effective crack arresters in mode I loading. To examine the sensitivity of delamina-tion damage on the strength of the cylinders, external pressure tests were performed on filament-wound glass/epoxy composite cylinders with artificial defects and impact damage. The results revealed that the cylinder strength was insensitive to the presence of single delaminations but impact damage caused reductions in failure pressure. The insensitivity of the failure pressure to a single delamination is attributed to the absence of buckling of the delaminated sublaminates before the cylinder wall collapsed. The impacted cylinders contained multiple delaminations, which caused local reduction in the compressive load capability and reduction in failure pressure. The response of glass/epoxy cylinders was compared to impacted carbon reinforced cylinders. Carbon/epoxy is more sensitive to damage but retains higher implosion resistance while carbon/PEEK shows the opposite trend.
Wu, Jia-Rong; DeWalt, Darren A; Baker, David W; Schillinger, Dean; Ruo, Bernice; Bibbins-Domingo, Kristen; Macabasco-O'Connell, Aurelia; Holmes, George M; Broucksou, Kimberly A; Erman, Brian; Hawk, Victoria; Cene, Crystal W; Jones, Christine DeLong; Pignone, Michael
2014-09-01
To determine whether a single-item self-report medication adherence question predicts hospitalisation and death in patients with heart failure. Poor medication adherence is associated with increased morbidity and mortality. Having a simple means of identifying suboptimal medication adherence could help identify at-risk patients for interventions. We performed a prospective cohort study in 592 participants with heart failure within a four-site randomised trial. Self-report medication adherence was assessed at baseline using a single-item question: 'Over the past seven days, how many times did you miss a dose of any of your heart medication?' Participants who reported no missing doses were defined as fully adherent, and those missing more than one dose were considered less than fully adherent. The primary outcome was combined all-cause hospitalisation or death over one year and the secondary endpoint was heart failure hospitalisation. Outcomes were assessed with blinded chart reviews, and heart failure outcomes were determined by a blinded adjudication committee. We used negative binomial regression to examine the relationship between medication adherence and outcomes. Fifty-two percent of participants were 52% male, mean age was 61 years, and 31% were of New York Heart Association class III/IV at enrolment; 72% of participants reported full adherence to their heart medicine at baseline. Participants with full medication adherence had a lower rate of all-cause hospitalisation and death (0·71 events/year) compared with those with any nonadherence (0·86 events/year): adjusted-for-site incidence rate ratio was 0·83, fully adjusted incidence rate ratio 0·68. Incidence rate ratios were similar for heart failure hospitalisations. A single medication adherence question at baseline predicts hospitalisation and death over one year in heart failure patients. Medication adherence is associated with all-cause and heart failure-related hospitalisation and death in heart failure. It is important for clinicians to assess patients' medication adherence on a regular basis at their clinical follow-ups. © 2013 John Wiley & Sons Ltd.
NASA Technical Reports Server (NTRS)
Bonnice, W. F.; Motyka, P.; Wagner, E.; Hall, S. R.
1986-01-01
The performance of the orthogonal series generalized likelihood ratio (OSGLR) test in detecting and isolating commercial aircraft control surface and actuator failures is evaluated. A modification to incorporate age-weighting which significantly reduces the sensitivity of the algorithm to modeling errors is presented. The steady-state implementation of the algorithm based on a single linear model valid for a cruise flight condition is tested using a nonlinear aircraft simulation. A number of off-nominal no-failure flight conditions including maneuvers, nonzero flap deflections, different turbulence levels and steady winds were tested. Based on the no-failure decision functions produced by off-nominal flight conditions, the failure detection and isolation performance at the nominal flight condition was determined. The extension of the algorithm to a wider flight envelope by scheduling on dynamic pressure and flap deflection is examined. Based on this testing, the OSGLR algorithm should be capable of detecting control surface failures that would affect the safe operation of a commercial aircraft. Isolation may be difficult if there are several surfaces which produce similar effects on the aircraft. Extending the algorithm over the entire operating envelope of a commercial aircraft appears feasible.
Validation Study of Unnotched Charpy and Taylor-Anvil Impact Experiments using Kayenta
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kamojjala, Krishna; Lacy, Jeffrey; Chu, Henry S.
2015-03-01
Validation of a single computational model with multiple available strain-to-failure fracture theories is presented through experimental tests and numerical simulations of the standardized unnotched Charpy and Taylor-anvil impact tests, both run using the same material model (Kayenta). Unnotched Charpy tests are performed on rolled homogeneous armor steel. The fracture patterns using Kayenta’s various failure options that include aleatory uncertainty and scale effects are compared against the experiments. Other quantities of interest include the average value of the absorbed energy and bend angle of the specimen. Taylor-anvil impact tests are performed on Ti6Al4V titanium alloy. The impact speeds of the specimenmore » are 321 m/s and 393 m/s. The goal of the numerical work is to reproduce the damage patterns observed in the laboratory. For the numerical study, the Johnson-Cook failure model is used as the ductile fracture criterion, and aleatory uncertainty is applied to rate-dependence parameters to explore its effect on the fracture patterns.« less
Morbi, Abigail H M; Hamady, Mohamad S; Riga, Celia V; Kashef, Elika; Pearch, Ben J; Vincent, Charles; Moorthy, Krishna; Vats, Amit; Cheshire, Nicholas J W; Bicknell, Colin D
2012-08-01
To determine the type and frequency of errors during vascular interventional radiology (VIR) and design and implement an intervention to reduce error and improve efficiency in this setting. Ethical guidance was sought from the Research Services Department at Imperial College London. Informed consent was not obtained. Field notes were recorded during 55 VIR procedures by a single observer. Two blinded assessors identified failures from field notes and categorized them into one or more errors by using a 22-part classification system. The potential to cause harm, disruption to procedural flow, and preventability of each failure was determined. A preprocedural team rehearsal (PPTR) was then designed and implemented to target frequent preventable potential failures. Thirty-three procedures were observed subsequently to determine the efficacy of the PPTR. Nonparametric statistical analysis was used to determine the effect of intervention on potential failure rates, potential to cause harm and procedural flow disruption scores (Mann-Whitney U test), and number of preventable failures (Fisher exact test). Before intervention, 1197 potential failures were recorded, of which 54.6% were preventable. A total of 2040 errors were deemed to have occurred to produce these failures. Planning error (19.7%), staff absence (16.2%), equipment unavailability (12.2%), communication error (11.2%), and lack of safety consciousness (6.1%) were the most frequent errors, accounting for 65.4% of the total. After intervention, 352 potential failures were recorded. Classification resulted in 477 errors. Preventable failures decreased from 54.6% to 27.3% (P < .001) with implementation of PPTR. Potential failure rates per hour decreased from 18.8 to 9.2 (P < .001), with no increase in potential to cause harm or procedural flow disruption per failure. Failures during VIR procedures are largely because of ineffective planning, communication error, and equipment difficulties, rather than a result of technical or patient-related issues. Many of these potential failures are preventable. A PPTR is an effective means of targeting frequent preventable failures, reducing procedural delays and improving patient safety.
Takeishi, Yasuchika; Minamihaba, Osamu; Yamauchi, Sou; Arimoto, Takanori; Hirono, Osamu; Takahashi, Hiroki; Akiyama, Hideyuki; Miyamoto, Takuya; Nitobe, Joji; Nozaki, Naoki; Tachibana, Hidetada; Okuyama, Masaki; Fukui, Akio; Kubota, Isao; Okada, Akio; Takahashi, Kazuei
2004-04-01
Heart failure is a major and growing public health problem with a high mortality rate. Although recent studies have demonstrated that a variety of metabolic and/or neurohumoral factors are involved in the progression of this syndrome, the precise mechanisms responsible for this complex condition are poorly understood. To examine 123I-beta-methyl-iodophenylpentadecanoic acid (BMIPP) kinetics in the early phase soon after tracer injection in patients with congestive heart failure (CHF), we performed dynamic single-photon emission computed tomography (SPECT). Twenty-six patients with CHF and eight control subjects were examined. The consecutive 15 images of 2-min dynamic SPECT were acquired for 30 min after injection. In the early phase after injection (0-4 min), a significant amount of radioactivity existed in the blood pool. After 6 min, the myocardial 123I-BMIPP image was clear and thus the washout rate of 123I-BMIPP from 6 to 30 min was calculated. The washout rate of 123I-BMIPP from the myocardium was faster in patients with CHF than in the controls (8 +/- 4 vs. -5 +/- 3%, p < 0.01). The washout rate of 123I-BMIPP demonstrated positive correlation with left ventricular (LV) end-diastolic volume index (R = 0.54, p < 0.02) and inverse correlation with LV ejection fraction (R = 0.53, p <0.02). Patients were given the angiotensin II type-1 receptor antagonist candesartan for 6 months, and dynamic SPECT was repeated. The enhanced washout rate of 123I-BMIPP in CHF was reduced after treatment with candesartan (p < 0.05). These data suggest that (1) enhanced washout of 123I-BMIPP was observed soon after injection in patients with CHF, (2) the activation of angiotensin II signaling pathway is involved as an intracellular mechanism for enhanced 123I-BMIPP washout in heart failure, and (3) improvement in fatty acid metabolism may represent a new mechanism for beneficial effects of angiotensin II receptor blockade on cardiac function and survival in patients with heart failure. 123I-BMIPP washout in the early phase obtained from dynamic SPECT may be a new marker for evaluating the severity of heart failure and the effects of medical treatment.
da Cunha, Sandra Ribeiro de Barros; Ramos, Pedro Augusto Minorin Mendes; Haddad, Cecília Maria Kalil; da Silva, João Luis Fernandes; Fregnani, Eduardo Rodrigues; Aranha, Ana Cecília Corrêa
2016-01-01
To evaluate the effects of three different radiation doses on the bond strengths of two different adhesive systems to enamel and dentin. Eighty human third molars were randomly divided into four groups (n = 20) according to the radiation dose (control/no radiation, 20 Gy, 40 Gy, and 70 Gy). The teeth were sagittally sectioned into three slices: one mesial and one distal section containing enamel and one middle section containing dentin. The sections were then placed in the enamel and dentin groups, which were further divided into two subgroups (n = 10) according to the adhesive used. Three restorations were performed in each tooth (one per section) using Adper Single Bond 2 (3M ESPE) or Universal Single Bond (3M ESPE) adhesive system and Filtek Z350 XT (3M ESPE) resin composite and subjected to the microshear bond test. Data were analyzed using a two-way ANOVA followed by Tukey's test. Failure modes were examined under a stereoscopic loupe. Radiotherapy did not affect the bond strengths of the adhesives to either enamel or dentin. In dentin, the Universal Single Bond adhesive system showed higher bond strength values when compared with the Adper Single Bond adhesive system. More adhesive failures were observed in the enamel for all radiation doses and adhesives. Radiotherapy did not influence the bond strength to enamel or dentin, irrespective of the adhesive or radiation dose used.
Pang, Liuyong; Shen, Lin; Zhao, Zhong
2016-01-01
To begin with, in this paper, single immunotherapy, single chemotherapy, and mixed treatment are discussed, and sufficient conditions under which tumor cells will be eliminated ultimately are obtained. We analyze the impacts of the least effective concentration and the half-life of the drug on therapeutic results and then find that increasing the least effective concentration or extending the half-life of the drug can achieve better therapeutic effects. In addition, since most types of tumors are resistant to common chemotherapy drugs, we consider the impact of drug resistance on therapeutic results and propose a new mathematical model to explain the cause of the chemotherapeutic failure using single drug. Based on this, in the end, we explore the therapeutic effects of two-drug combination chemotherapy, as well as mixed immunotherapy with combination chemotherapy. Numerical simulations indicate that combination chemotherapy is very effective in controlling tumor growth. In comparison, mixed immunotherapy with combination chemotherapy can achieve a better treatment effect. PMID:26997972
Pang, Liuyong; Shen, Lin; Zhao, Zhong
2016-01-01
To begin with, in this paper, single immunotherapy, single chemotherapy, and mixed treatment are discussed, and sufficient conditions under which tumor cells will be eliminated ultimately are obtained. We analyze the impacts of the least effective concentration and the half-life of the drug on therapeutic results and then find that increasing the least effective concentration or extending the half-life of the drug can achieve better therapeutic effects. In addition, since most types of tumors are resistant to common chemotherapy drugs, we consider the impact of drug resistance on therapeutic results and propose a new mathematical model to explain the cause of the chemotherapeutic failure using single drug. Based on this, in the end, we explore the therapeutic effects of two-drug combination chemotherapy, as well as mixed immunotherapy with combination chemotherapy. Numerical simulations indicate that combination chemotherapy is very effective in controlling tumor growth. In comparison, mixed immunotherapy with combination chemotherapy can achieve a better treatment effect.
Drug user treatment failure blindness?
Einstein, Stan
2012-01-01
An ethnographic case study of a "failed" single goal (abstinence) based individual and group therapy treatment of a New York City, Harlem-based, single, young-adult of color, IDU, mother, which ended in "death by overdose," after a period of abstinence, is presented almost 50 years later, in which complex, multidimensional structural barriers, "normed," consensualized, ideologically-driven preconceptions and an array of contextual, situational and relevant stakeholder factors, which may have resulted in intervention "failure blindness," are reviewed. The need to introduce failure analysis, blindness and management, as well as success analysis, blindness and management, as integral parts of treatment planning, implementation and assessment is raised.
Ventricular assist device use in single ventricle congenital heart disease.
Carlo, Waldemar F; Villa, Chet R; Lal, Ashwin K; Morales, David L
2017-11-01
As VAD have become an effective therapy for end-stage heart failure, their application in congenital heart disease has increased. Single ventricle congenital heart disease introduces unique physiologic challenges for VAD use. However, with regard to the mixed clinical results presented within this review, we suggest that patient selection, timing of implant, and center experience are all important contributors to outcome. This review focuses on the published experience of VAD use in single ventricle patients and details physiologic challenges and novel approaches in this growing pediatric and adult population. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
El-Agamy, Dina S; Makled, Mirhan N; Gamil, Nareman M
2014-06-01
Fulminant hepatic failure (FHF) is a life-threatening syndrome characterized by massive hepatic necrosis and high mortality. There is no effective therapy for the disease other than liver transplantation. This study aimed to investigate the effect of agmatine, inducible nitric oxide synthase (iNOS) inhibitor, on D-galactosamine and lipopolysaccharide (GalN/LPS)-induced FHF in mice and explore its possible mechanism(s). Male Swiss albino mice were injected with a single dose agmatine (14 mg/kg, IP) 8 h prior to challenge with a single intraperitoneal injection of both GalN (800 mg/kg) and LPS (50 μg/kg). Agmatine significantly attenuated all GalN/LPS-induced biochemical and pathological changes in liver. It prevented the increase of serum transaminases and alkaline phosphatase (ALP). In addition, agmatine markedly attenuated GalN/LPS-induced necrosis and inflammation. Agmatine significantly reduced oxidative stress and enhanced antioxidant enzymes. Importantly, agmatine decreased total nitric oxide (NO) and pro-inflammatory cytokine, tumor necrosis factor-alpha (TNF-α). These findings reveal that agmatine has hepatoprotective effects against GalN/LPS-induced FHF in mice that may be related to its ability to suppress oxidative stress, NO synthesis and TNF-α production. Therefore, agmatine may serve as a novel therapeutic strategy for hepatic inflammatory diseases.
Validation techniques for fault emulation of SRAM-based FPGAs
Quinn, Heather; Wirthlin, Michael
2015-08-07
A variety of fault emulation systems have been created to study the effect of single-event effects (SEEs) in static random access memory (SRAM) based field-programmable gate arrays (FPGAs). These systems are useful for augmenting radiation-hardness assurance (RHA) methodologies for verifying the effectiveness for mitigation techniques; understanding error signatures and failure modes in FPGAs; and failure rate estimation. For radiation effects researchers, it is important that these systems properly emulate how SEEs manifest in FPGAs. If the fault emulation systems does not mimic the radiation environment, the system will generate erroneous data and incorrect predictions of behavior of the FPGA inmore » a radiation environment. Validation determines whether the emulated faults are reasonable analogs to the radiation-induced faults. In this study we present methods for validating fault emulation systems and provide several examples of validated FPGA fault emulation systems.« less
Munderi, Paula; Kityo, Cissy; Reid, Andrew; Katabira, Elly; Goodall, Ruth L.; Grosskurth, Heiner; Mugyenyi, Peter; Hakim, James; Gibb, Diana M.
2013-01-01
Background In low-income countries, viral load (VL) monitoring of antiretroviral therapy (ART) is rarely available in the public sector for HIV-infected adults or children. Using clinical failure alone to identify first-line ART failure and trigger regimen switch may result in unnecessary use of costly second-line therapy. Our objective was to identify CD4 threshold values to confirm clinically-determined ART failure when VL is unavailable. Methods 3316 HIV-infected Ugandan/Zimbabwean adults were randomised to first-line ART with Clinically-Driven (CDM, CD4s measured but blinded) or routine Laboratory and Clinical Monitoring (LCM, 12-weekly CD4s) in the DART trial. CD4 at switch and ART failure criteria (new/recurrent WHO 4, single/multiple WHO 3 event; LCM: CD4<100 cells/mm3) were reviewed in 361 LCM, 314 CDM participants who switched over median 5 years follow-up. Retrospective VLs were available in 368 (55%) participants. Results Overall, 265/361 (73%) LCM participants failed with CD4<100 cells/mm3; only 7 (2%) switched with CD4≥250 cells/mm3, four switches triggered by WHO events. Without CD4 monitoring, 207/314 (66%) CDM participants failed with WHO 4 events, and 77(25%)/30(10%) with single/multiple WHO 3 events. Failure/switching with single WHO 3 events was more likely with CD4≥250 cells/mm3 (28/77; 36%) (p = 0.0002). CD4 monitoring reduced switching with viral suppression: 23/187 (12%) LCM versus 49/181 (27%) CDM had VL<400 copies/ml at failure/switch (p<0.0001). Amongst CDM participants with CD4<250 cells/mm3 only 11/133 (8%) had VL<400copies/ml, compared with 38/48 (79%) with CD4≥250 cells/mm3 (p<0.0001). Conclusion Multiple, but not single, WHO 3 events predicted first-line ART failure. A CD4 threshold ‘tiebreaker’ of ≥250 cells/mm3 for clinically-monitored patients failing first-line could identify ∼80% with VL<400 copies/ml, who are unlikely to benefit from second-line. Targeting CD4s to single WHO stage 3 ‘clinical failures’ would particularly avoid premature, costly switch to second-line ART. PMID:23437399
NASA Technical Reports Server (NTRS)
Vanschalkwyk, Christiaan M.
1992-01-01
We discuss the application of Generalized Parity Relations to two experimental flexible space structures, the NASA Langley Mini-Mast and Marshall Space Flight Center ACES mast. We concentrate on the generation of residuals and make no attempt to implement the Decision Function. It should be clear from the examples that are presented whether it would be possible to detect the failure of a specific component. We derive the equations from Generalized Parity Relations. Two special cases are treated: namely, Single Sensor Parity Relations (SSPR) and Double Sensor Parity Relations (DSPR). Generalized Parity Relations for actuators are also derived. The NASA Langley Mini-Mast and the application of SSPR and DSPR to a set of displacement sensors located at the tip of the Mini-Mast are discussed. The performance of a reduced order model that includes the first five models of the mast is compared to a set of parity relations that was identified on a set of input-output data. Both time domain and frequency domain comparisons are made. The effect of the sampling period and model order on the performance of the Residual Generators are also discussed. Failure detection experiments where the sensor set consisted of two gyros and an accelerometer are presented. The effects of model order and sampling frequency are again illustrated. The detection of actuator failures is discussed. We use Generalized Parity Relations to monitor control system component failures on the ACES mast. An overview is given of the Failure Detection Filter and experimental results are discussed. Conclusions and directions for future research are given.
Jones, Ryan T; Handsfield, Lydia; Read, Paul W; Wilson, David D; Van Ausdal, Ray; Schlesinger, David J; Siebers, Jeffrey V; Chen, Quan
2015-01-01
The clinical challenge of radiation therapy (RT) for painful bone metastases requires clinicians to consider both treatment efficacy and patient prognosis when selecting a radiation therapy regimen. The traditional RT workflow requires several weeks for common palliative RT schedules of 30 Gy in 10 fractions or 20 Gy in 5 fractions. At our institution, we have created a new RT workflow termed "STAT RAD" that allows clinicians to perform computed tomographic (CT) simulation, planning, and highly conformal single fraction treatment delivery within 2 hours. In this study, we evaluate the safety and feasibility of the STAT RAD workflow. A failure mode and effects analysis (FMEA) was performed on the STAT RAD workflow, including development of a process map, identification of potential failure modes, description of the cause and effect, temporal occurrence, and team member involvement in each failure mode, and examination of existing safety controls. A risk probability number (RPN) was calculated for each failure mode. As necessary, workflow adjustments were then made to safeguard failure modes of significant RPN values. After workflow alterations, RPN numbers were again recomputed. A total of 72 potential failure modes were identified in the pre-FMEA STAT RAD workflow, of which 22 met the RPN threshold for clinical significance. Workflow adjustments included the addition of a team member checklist, changing simulation from megavoltage CT to kilovoltage CT, alteration of patient-specific quality assurance testing, and allocating increased time for critical workflow steps. After these modifications, only 1 failure mode maintained RPN significance; patient motion after alignment or during treatment. Performing the FMEA for the STAT RAD workflow before clinical implementation has significantly strengthened the safety and feasibility of STAT RAD. The FMEA proved a valuable evaluation tool, identifying potential problem areas so that we could create a safer workflow. Copyright © 2015 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.
Multi-spectral investigation of bulk and facet failures in high-power single emitters at 980 nm
NASA Astrophysics Data System (ADS)
Yanson, Dan; Levy, Moshe; Shamay, Moshe; Cohen, Shalom; Shkedy, Lior; Berk, Yuri; Tessler, Renana; Klumel, Genadi; Rappaport, Noam; Karni, Yoram
2013-03-01
Reliable single emitters delivering >10W in the 9xx nm spectral range, are common building blocks for fiber laser pumps. As facet passivation techniques can suppress or delay catastrophic optical mirror damage (COMD) extending emitter reliability into hundreds of thousands of hours, other, less dominant, failure modes such as intra-chip catastrophic optical bulk damage (COBD) become apparent. Based on our failure statistics in high current operation, only ~52% of all failures can be attributed to COMD. Imaging through a window opened in the metallization on the substrate (n) side of a p-side down mounted emitter provides valuable insight into both COMD and COBD failure mechanisms. We developed a laser ablation process to define a window on the n-side of an InGaAs/AlGaAs 980nm single emitter that is overlaid on the pumped 90μm stripe on the p-side. The ablation process is compatible with the chip wire-bonding, enabling the device to be operated at high currents with high injection uniformity. We analyzed both COMD and COBD failed emitters in the electroluminescence and mid-IR domains supported by FIB/SEM observation. The ablated devices revealed branching dark line patterns, with a line origin either at the facet center (COMD case) or near the stripe edge away from the facet (COBD case). In both cases, the branching direction is always toward the rear facet (against the photon density gradient), with SEM images revealing a disordered active layer structure. Absorption levels between 0.22eV - 0.55eV were observed in disordered regions by FT-IR spectroscopy. Temperature mapping of a single emitter in the MWIR domain was performed using an InSb detector. We also report an electroluminescence study of a single emitter just before and after failure.
NASA Astrophysics Data System (ADS)
Spinner, Neil S.; Field, Christopher R.; Hammond, Mark H.; Williams, Bradley A.; Myers, Kristina M.; Lubrano, Adam L.; Rose-Pehrsson, Susan L.; Tuttle, Steven G.
2015-04-01
A 5-cubic meter decompression chamber was re-purposed as a fire test chamber to conduct failure and abuse experiments on lithium-ion batteries. Various modifications were performed to enable remote control and monitoring of chamber functions, along with collection of data from instrumentation during tests including high speed and infrared cameras, a Fourier transform infrared spectrometer, real-time gas analyzers, and compact reconfigurable input and output devices. Single- and multi-cell packages of LiCoO2 chemistry 18650 lithium-ion batteries were constructed and data was obtained and analyzed for abuse and failure tests. Surrogate 18650 cells were designed and fabricated for multi-cell packages that mimicked the thermal behavior of real cells without using any active components, enabling internal temperature monitoring of cells adjacent to the active cell undergoing failure. Heat propagation and video recordings before, during, and after energetic failure events revealed a high degree of heterogeneity; some batteries exhibited short burst of sparks while others experienced a longer, sustained flame during failure. Carbon monoxide, carbon dioxide, methane, dimethyl carbonate, and ethylene carbonate were detected via gas analysis, and the presence of these species was consistent throughout all failure events. These results highlight the inherent danger in large format lithium-ion battery packs with regards to cell-to-cell failure, and illustrate the need for effective safety features.
Zanoni, R G; Bugnon, Ph; Deranleau, E; Nguyen, T M V; Brügger, D
2010-12-01
Data of 13'469 blood samples from 10'999 dogs and 2'470 cats tested for rabies neutralizing antibodies within the framework of pet travel schemes were analysed for single and combined factors influencing antibody titres and failures. The time span between vaccination and drawing the blood sample was confirmed as a major source of failure in dogs with a proportion of 23 % at 4 months after primary vaccination (single dose). Failures in dogs and cats (titre < 0.5 IU) were significantly reduced after double primary vaccination (2 doses within 7 - 10 days), although failures reached comparable levels in dogs as early as 6 months after vaccination. In contrast, failure after vaccination was generally below 5 % in dogs and absent in cats after a booster applied at earliest 12 months after single primary vaccination. Statistically significant differences between the failures of the vaccine brands «Rabisin» (1.5 %), «Defensor» (6.7 %), «Nobivac Rabies» (11.0 %) and «Rabdomun» (18.2 %) were found in dogs but also between the titres induced in cats. Significant differences were found between different dog breeds with some small breeds showing a significantly higher responsiveness. Taken together, a new regimen for rabies vaccination consisting of double primary vaccination with a short interval of 7 - 10 days and a one-year booster appears to be highly recommended for dogs and cats.
Single living predicts a higher mortality in both women and men with chronic heart failure.
Mard, Shan; Nielsen, Finn Erland
2016-09-01
We examined the impact of single living on all-cause mortality in patients with chronic heart failure and determined if this association was modified by gender. This historical cohort study included 637 patients who were admitted to the Department of Cardiology, Herlev Hospital, Denmark, between 1 July 2005 and 30 June 2007. Baseline clinical data were obtained from patient records. Data on survival rates were obtained from the Danish Civil Registration System. Cox proportional hazard analysis was used to compute the hazard ratio (HR) of all-cause mortality, controlling for confounding factors. The median follow-up time was 2.8 years. A total of 323 (50.7%) patients died during the follow-up period. After adjustment for confounding factors, risk of death was associated with being single (HR = 1.53 (95% confidence interval: 1.19-1.96)). In a gender-stratified analysis, the risk of death did not differ among single-living women and men. Single living is a prognostic determinant of all-cause mortality in men and women with chronic heart failure. none. not relevant.
Effects of fiber, matrix, and interphase on carbon fiber composite compression strength
NASA Technical Reports Server (NTRS)
Nairn, John A.; Harper, Sheila I.; Bascom, Willard D.
1994-01-01
The major goal of this project was to obtain basic information on compression failure properties of carbon fiber composites. To do this, we investigated fiber effects, matrix effects, and fiber/matrix interface effects. Using each of nine fiber types, we prepared embedded single-fiber specimens, single-ply specimens, and full laminates. From the single-fiber specimens, in addition to the standard fragmentation test analysis, we were able to use the low crack density data to provide information about the distribution of fiber flaws. The single-ply specimens provided evidence of a correlation between the size of kink band zones and the quality of the interface. Results of the laminate compression experiments mostly agreed with the results from single-ply experiments, although the ultimate compression strengths of laminates were higher. Generally, these experiments showed a strong effect of interfacial properties. Matrix effects were examined using laminates subjected to precracking under mixed-mode loading conditions. A large effect of precracking conditions on the mode 1 toughness of the laminates was found. In order to control the properties of the fiber/matrix interface, we prepared composites of carbon fiber and polycarbonate and subjected these to annealing. The changes in interfacial properties directly correlated with changes in compression strength.
Alqutaibi, A Y; Kaddah, A F; Farouk, M
2017-06-01
The objective was to evaluate and compare single- and two-implant retained overdentures for the rehabilitation of the edentulous mandible. Fifty-six edentulous subjects were eligible for inclusion. Using a random sampling system, a single implant or two implants were placed in the mandible. After 3 months, locator attachments were connected to the implants and the denture delivered with the retentive components incorporated in the denture base. Implant failure and muscle activity were evaluated at the 3-, 6-, and 12-month follow-up examinations. The study sample comprised 56 patients (32 male, 24 female), with a mean age of 58.2 years. A total of 84 implants were placed (28 in the single-implant group and 56 in the two-implant group). All patients completed the 12 months of follow-up. No significant differences were found between subjects in the two groups with respect to implant failure. With regard to improvements in muscle activity, the two-implant group showed statistically significant but perhaps not clinically important differences. Single-implant mandibular overdentures may be suggested as an alternative treatment modality for the rehabilitation of edentulous patients who cannot afford the cost of a two-implant overdenture. Copyright © 2017 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.
Modeling of a bubble-memory organization with self-checking translators to achieve high reliability.
NASA Technical Reports Server (NTRS)
Bouricius, W. G.; Carter, W. C.; Hsieh, E. P.; Wadia, A. B.; Jessep, D. C., Jr.
1973-01-01
Study of the design and modeling of a highly reliable bubble-memory system that has the capabilities of: (1) correcting a single 16-adjacent bit-group error resulting from failures in a single basic storage module (BSM), and (2) detecting with a probability greater than 0.99 any double errors resulting from failures in BSM's. The results of the study justify the design philosophy adopted of employing memory data encoding and a translator to correct single group errors and detect double group errors to enhance the overall system reliability.
Marinšek, Martin; Sinkovič, Andreja
2016-01-01
Blocking the renin-angiotensin-aldosterone system in ST-elevation myocardial infarction (STEMI) patients prevents heart failure and recurrent thrombosis. Our aim was to compare the effects of ramipril and losartan upon the markers of heart failure, endogenous fibrinolysis, and platelet aggregation in STEMI patients over the long term. After primary percutaneous coronary intervention (PPCI), 28 STEMI patients were randomly assigned ramipril and 27 losartan, receiving therapy for six months with dual antiplatelet therapy (DAPT). We measured N-terminal proBNP (NT-proBNP), ejection fraction (EF), plasminogen-activator-inhibitor type 1 (PAI-1), and platelet aggregation by closure times (CT) at the baseline and after six months. Baseline NT-proBNP ≥ 200 pmol/mL was observed in 48.1% of the patients, EF < 55% in 49.1%, and PAI-1 ≥ 3.5 U/mL in 32.7%. Six-month treatment with ramipril or losartan resulted in a similar effect upon PAI-1, NT-proBNP, EF, and CT levels in survivors of STEMI, but in comparison to control group, receiving DAPT alone, ramipril or losartan treatment with DAPT significantly increased mean CT (226.7 ± 80.3 sec versus 158.1 ± 80.3 sec, p < 0.05). Ramipril and losartan exert a similar effect upon markers of heart failure and endogenous fibrinolysis, and, with DAPT, a more efficient antiplatelet effect in long term than DAPT alone.
Noyes, Matthew P; Lederman, Evan; Adams, Christopher R; Denard, Patrick J
2018-05-01
To compare the biomechanical properties of single-row repair with triple-loaded (TL) anchor repair versus a knotless rip stop (KRS) repair in a rotator cuff repair model. Rotator cuff tears were created in 8 cadaveric matched-pair specimens and repaired with a TL anchor or KRS construct. In the TL construct, anchors were placed in the greater tuberosity and then all suture limbs were passed through the rotator cuff as simple sutures and tied. In the KRS construct, a 2-mm suture tape was passed through the tendon in an inverted mattress fashion, and a free suture was passed medial to the suture tape to create a rip-stop. Then, the suture tape and free suture were secured with knotless anchors. Displacement was observed with video tracking after cyclic loading, and specimens were loaded to failure. The mean load to failure was 438 ± 59 N in TL anchor repairs compared with 457 ± 110 N in KRS repairs (P = .582). The mean displacement with cyclic loading was 3.8 ± 1.6 mm in TL anchor repairs versus 4.3 ± 1.8 mm in the KRS group (P = .297). Mode of failure was consistent in both groups, with 6 of 8 failures in the TL anchor group and 7 of 8 failures in KRS group occurring from anchor pullout. There is no statistical difference in load to failure and cyclic loading between TL anchor and KRS single-row repair techniques. KRS repair technique may be an alternative method of repairing full-thickness supraspinatus tendon tears with a single-row construct. Copyright © 2018 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Krebs, K.
Testing programs carried out by the European Communities to establish testing techniques and standards for verifying the reliability and integrity of solar cells intended for the marketplace are described. The efforts are being expended to assure quality control and certification for photovoltaic (PV) products manufactured in any of the member nations. The failure rate for PV modules was lowered to 0.5 pct/year by 1981, and single cell failures are projected to be lowered to 0.00001/yr, connectors to 0.001/yr, and batteries to 0.01/yr. Day/night thermal cycling causes the most dominant type of failures, i.e., cracked cells and interconnect defects. Tests have been standardized for inspection, verification, performance, mechanical loading, hail impact, damp heat, high temperature long exposure, hot-spot heating, thermal cycling, and humidity-freezing tolerance.
Assessment of Multiaxial Mechanical Response of Rigid Polyurethane Foams
NASA Astrophysics Data System (ADS)
Pettarin, Valeria; Fasce, Laura A.; Frontini, Patricia M.
2014-02-01
Multiaxial deformation behavior and failure surface of rigid polyurethane foams were determined using standard experimental facilities. Two commercial foams of different densities were assayed under uniaxial, biaxial, and triaxial stress states. These different stress states were reached in a uniaxial universal testing machine using suitable testing configurations which imply the use of special grips and lateral restricted samples. Actual strains were monitored with a video extensometer. Polyurethane foams exhibited typical isotropic brittle behavior, except under compressive loads where the response turned out to be ductile. A general failure surface in the stress space which accounts for density effects could be successfully generated. All of failure data, determined at the loss of linear elasticity point, collapsed in a single locus defined as the combination of a brittle crushing of closed-cell cellular materials criterion capped by an elastic buckling criterion.
Lovelock, D Michael; Zhang, Zhigang; Jackson, Andrew; Keam, Jennifer; Bekelman, Justin; Bilsky, Mark; Lis, Eric; Yamada, Yoshiya
2010-07-15
In the setting of high-dose single-fraction image-guided radiotherapy of spine metastases, the delivered dose is hypothesized to be a significant factor in local control. We investigated the dependence of local control on measures of dose insufficiency. The minimum doses received by the hottest 100%, 98%, and 95% (D(min), D(98), and D(95)) of the gross target volume (GTV) were computed for 91 consecutively treated lesions observed in 79 patients. Prescribed doses of 18-24 Gy were delivered in a single fraction. The spinal cord and cauda equina were constrained to a maximum dose of 12-14 Gy and 16 Gy, respectively. A rank-sum test was used to assess the differences between radiographic local failure and local control. With a median follow-up of 18 months, seven local failures have occurred. The distributions of GTV D(min), D(98), and D(95) for treatments resulting in local failure were found to be statistically different from the corresponding distributions of the patient group as a whole. Taking no account of histology, p values calculated for D(min), D(98), and D(95) were 0.004, 0.012, and 0.031, respectively. No correlations between local failure and target volume or between local failure and anatomic location were found. The results indicate that D(min), D(98), and D(95) may be important risk factors for local failure. No local failures in any histology were observed when D(min) was >15 Gy, suggesting that this metric may be an important predictor of local control. Copyright 2010 Elsevier Inc. All rights reserved.
Lovelock, D. Michael; Zhang, Zhigang; Jackson, Andrew; Keam, Jennifer; Bekelman, Justin; Bilsky, Mark; Lis, Eric; Yamada, Yoshiya
2011-01-01
Purpose In the setting of high-dose single-fraction image-guided radiotherapy of spine metastases, the delivered dose is hypothesized to be a significant factor in local control. We investigated the dependence of local control on measures of dose insufficiency. Methods and Materials The minimum doses received by the hottest 100%, 98%, and 95% (Dmin, D98, and D95) of the gross target volume (GTV) were computed for 91 consecutively treated lesions observed in 79 patients. Prescribed doses of 18–24 Gy were delivered in a single fraction. The spinal cord and cauda equina were constrained to a maximum dose of 12–14 Gy and 16 Gy, respectively. A rank-sum test was used to assess the differences between radiographic local failure and local control. Results With a median follow-up of 18 months, seven local failures have occurred. The distributions of GTV Dmin, D98, and D95 for treatments resulting in local failure were found to be statistically different from the corresponding distributions of the patient group as a whole. Taking no account of histology, p values calculated for Dmin, D98, and D95 were 0.004, 0.012, and 0.031, respectively. No correlations between local failure and target volume or between local failure and anatomic location were found. Conclusions The results indicate that Dmin, D98, and D95 may be important risk factors for local failure. No local failures in any histology were observed when Dmin was >15 Gy, suggesting that this metric may be an important predictor of local control. PMID:20350795
NASA Technical Reports Server (NTRS)
Farley, Gary L.; Seshadri, Banavara R.
2005-01-01
An analysis based investigation of aluminum with metal matrix composite selectively reinforced single- and multi-hole specimens was performed and their results compared with results from geometrically comparable non-reinforced specimens. All reinforced specimens exhibited a significant increase in performance. Performance increase of up to 170 percent was achieved. Specimen failure modes were consistent with results from reinforced polymeric matrix composite specimens. Localized reinforcement application (circular) proved as effective as a broader area (strip) reinforcement. Also, selective reinforcement is an excellent method of increasing the performance of multi-hole specimens.
Model 0A wind turbine generator FMEA
NASA Technical Reports Server (NTRS)
Klein, William E.; Lalli, Vincent R.
1989-01-01
The results of Failure Modes and Effects Analysis (FMEA) conducted for the Wind Turbine Generators are presented. The FMEA was performed for the functional modes of each system, subsystem, or component. The single-point failures were eliminated for most of the systems. The blade system was the only exception. The qualitative probability of a blade separating was estimated at level D-remote. Many changes were made to the hardware as a result of this analysis. The most significant change was the addition of the safety system. Operational experience and need to improve machine availability have resulted in subsequent changes to the various systems which are also reflected in this FMEA.
Single-Case Analysis to Determine Reasons for Failure of Behavioral Treatment via Telehealth
ERIC Educational Resources Information Center
Schieltz, Kelly M.; Romani, Patrick W.; Wacker, David P.; Suess, Alyssa N.; Huang, Pei; Berg, Wendy K.; Lindgren, Scott D.; Kopelman, Todd G.
2018-01-01
Functional communication training (FCT) is a widely used and effective function-based treatment for problem behavior. The purpose of this article is to present two cases in which FCT was unsuccessful in reducing the occurrence of problem behavior displayed by two young children with an autism spectrum disorder. Both children received the same…
People's Financial Choice Depends on their Previous Task Success or Failure.
Sekścińska, Katarzyna
2015-01-01
Existing knowledge about the impact of the experience prior to financial choices has been limited almost exclusively to single risky choices. Moreover, the results obtained in these studies have not been entirely consistent. For example, some studies suggested that the experience of success makes people more willing to take a risk, while other studies led to the opposite conclusions. The results of the two experimental studies presented in this paper provide evidence for the hypothesis that the experience of success or failure influences people's financial choices, but the effect of the success or failure depends on the type of task (financial and non-financial) preceding a financial decision. The experience of success in financial tasks increased participants' tendency to invest and make risky investment choices, while it also made them less prone to save. On the other hand, the experience of failure heightened the amount of money that participants decided to save, and lowered their tendency to invest and make risky investment choices. However, the effects of the experience of success or failure in non-financial tasks were exactly the opposite. The presented studies indicated the role of the specific circumstances in which the individual gains the experience as a possible way to explain the discrepancies in the results of studies on the relationship between the experience prior to financial choice with a tendency to take risks.
People’s Financial Choice Depends on their Previous Task Success or Failure
Sekścińska, Katarzyna
2015-01-01
Existing knowledge about the impact of the experience prior to financial choices has been limited almost exclusively to single risky choices. Moreover, the results obtained in these studies have not been entirely consistent. For example, some studies suggested that the experience of success makes people more willing to take a risk, while other studies led to the opposite conclusions. The results of the two experimental studies presented in this paper provide evidence for the hypothesis that the experience of success or failure influences people’s financial choices, but the effect of the success or failure depends on the type of task (financial and non-financial) preceding a financial decision. The experience of success in financial tasks increased participants’ tendency to invest and make risky investment choices, while it also made them less prone to save. On the other hand, the experience of failure heightened the amount of money that participants decided to save, and lowered their tendency to invest and make risky investment choices. However, the effects of the experience of success or failure in non-financial tasks were exactly the opposite. The presented studies indicated the role of the specific circumstances in which the individual gains the experience as a possible way to explain the discrepancies in the results of studies on the relationship between the experience prior to financial choice with a tendency to take risks. PMID:26635654
Readmission for dehydration or renal failure after ileostomy creation.
Paquette, Ian M; Solan, Patrick; Rafferty, Janice F; Ferguson, Martha A; Davis, Bradley R
2013-08-01
Ileostomy creation is a commonly performed operation in colorectal surgery; however, many patients develop complications such as dehydration postoperatively. Dehydration is often severe enough to warrant hospital readmission and may result in renal failure. The true incidence of this complication has not been well described. The aim of this study was to identify the rate of hospital readmission secondary to dehydration or renal failure within 30 days of ileostomy creation. Retrospective review of all patients undergoing ileostomy creation from 2007 to 2011 in a single colorectal practice of 4 surgeons was performed. Charts were reviewed to identify patients readmitted for dehydration or renal failure within 30 days of operation. Data were then analyzed to identify predictors of readmission, dehydration, and renal failure. Subset analysis compared patients readmitted with simple dehydration versus patients with renal failure. Two hundred one patients undergoing colorectal operations that included ileostomy creation within a 4-year period at a single institution for a variety of indications were included. The primary outcome measured was readmission for dehydration or renal failure. We observed a 17% 30-day readmission rate for dehydration or renal failure following ileostomy creation. Age greater than 50 was identified as an independent predictor of readmission with renal failure, whereas IPAA was predictive of readmission for simple dehydration, but not renal failure. Patients admitted with renal failure had significantly longer hospital stays and median hospital charges after readmission in comparison with patients admitted with simple dehydration. This study was limited by its retrospective nature and its limited sample size. Hospital readmission due to dehydration or renal failure following ileostomy creation is common, with age >50 being the strongest predictor for renal failure. Appropriate strategies to decrease dehydration and renal failure following ileostomy creation need to be investigated.
Shohel, Mohammad; Rahman, Mohammad Mahfuzur; Zaman, Asif; Uddin, Mir Muhammad Nasir; Al-Amin, Md Mamun; Reza, Hasan Mahmud
2014-04-04
Unintended pregnancy is a complex phenomenon which raise to take an emergency decision. Low contraceptive prevalence and high user failure rates are the leading causes of this unexpected situation. High user failure rates suggest the vital role of emergency contraception to prevent unplanned pregnancy. Levonorgestrel - a commonly used progestin for emergency contraception. However, little is known about its pharmacokinetics and optimal dose for use. Hence, there is a need to conduct a systematic review of the available evidences. Randomized, double-blind trials were sought, evaluating healthy women with regular menstrual cycles, who requested emergency contraception within 72 h of unprotected coitus, to one of three regimens: 1.5 mg single dose levonorgestrel, two doses of 0.75 mg levonorgestrel given 12 h apart or two doses of 0.75 mg levonorgestrel given 24 h apart. The primary outcome was unintended pregnancy; other outcomes were side-effects and timing of next menstruation. Every trial under consideration successfully established the contraceptive effectiveness of levonorgestrel for preventing unintended pregnancy. Moreover, a single dose of levonorgestrel 1.5 mg for emergency contraception supports its safety and efficacy profile. If two doses of levonorgestrel 0.75 mg are intended for administration, the second dose can positively be taken 12-24 h after the first dose without compromising its contraceptive efficacy. The main side effect was frequent menstrual irregularities. No serious adverse events were reported. The review shows that, emergency contraceptive regimen of single-dose levonorgestrel is not inferior in efficacy to the two-dose regimen. All the regimens studied were very efficacious for emergency contraception and prevented a high proportion of pregnancies if taken within 72 h of unprotected coitus. Single levonorgestrel dose (1.5 mg) can substitute two 0.75 mg doses 12 or 24 h apart. With either regimen, the earlier the treatment is given, the more effective it seems to be.
2014-01-01
Background Unintended pregnancy is a complex phenomenon which raise to take an emergency decision. Low contraceptive prevalence and high user failure rates are the leading causes of this unexpected situation. High user failure rates suggest the vital role of emergency contraception to prevent unplanned pregnancy. Levonorgestrel - a commonly used progestin for emergency contraception. However, little is known about its pharmacokinetics and optimal dose for use. Hence, there is a need to conduct a systematic review of the available evidences. Methods Randomized, double-blind trials were sought, evaluating healthy women with regular menstrual cycles, who requested emergency contraception within 72 h of unprotected coitus, to one of three regimens: 1.5 mg single dose levonorgestrel, two doses of 0.75 mg levonorgestrel given 12 h apart or two doses of 0.75 mg levonorgestrel given 24 h apart. The primary outcome was unintended pregnancy; other outcomes were side-effects and timing of next menstruation. Results Every trial under consideration successfully established the contraceptive effectiveness of levonorgestrel for preventing unintended pregnancy. Moreover, a single dose of levonorgestrel 1.5 mg for emergency contraception supports its safety and efficacy profile. If two doses of levonorgestrel 0.75 mg are intended for administration, the second dose can positively be taken 12–24 h after the first dose without compromising its contraceptive efficacy. The main side effect was frequent menstrual irregularities. No serious adverse events were reported. Conclusions The review shows that, emergency contraceptive regimen of single-dose levonorgestrel is not inferior in efficacy to the two-dose regimen. All the regimens studied were very efficacious for emergency contraception and prevented a high proportion of pregnancies if taken within 72 h of unprotected coitus. Single levonorgestrel dose (1.5 mg) can substitute two 0.75 mg doses 12 or 24 h apart. With either regimen, the earlier the treatment is given, the more effective it seems to be. PMID:24708837
Missau, Taiane; De Carlo Bello, Mariana; Michelon, Carina; Mastella Lang, Pauline; Kalil Pereira, Gabriel; Baldissara, Paolo; Valandro, Luiz Felipe; Souza Bier, Carlos Alexandre; Pivetta Rippe, Marília
2017-12-01
This study evaluated the effects of endodontic treatment and retreatment on the fatigue failure load, numbers of cycles for failure, and survival rates of canine teeth. Sixty extracted canine teeth, each with a single root canal, were selected and randomly divided into 4 groups (n = 15): untreated, teeth without endodontic intervention; prepared, teeth subjected only to rotary instrumentation; filled, teeth receiving complete endodontic treatment; and retreated, teeth retreated endodontically. After the different endodontic interventions, the specimens were subjected to fatigue testing by the stepwise method: 200 N (× 5000 load pulses), 300 N, 400 N, 500 N, 600 N, 800 N, and 900 N at a maximum of 30,000 load pulses each or the occurrence of fracture. Data from load to failure and numbers of cycles for fracture were recorded and subjected to Kaplan-Meier and Log Rank tests (P < .05), in addition to Weibull analysis. The fractures of the specimens were classified as repairable or catastrophic. The retreated, filled, and untreated groups presented statistically significantly higher fatigue failure loads and numbers of cycles for failure than did the prepared group. Weibull analysis showed no statistically significant difference among the treatments for characteristic load to failure and characteristic number of cycles for failure, although, for number of cycles, a higher Weibull modulus was observed in filled and retreated conditions. The predominant mode of failure was catastrophic. Teeth subjected to complete endodontic treatment and retreatment behaved similarly in terms of fatigue failure load and number of cycles to failure when compared with untreated teeth. Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Management of heart failure in the new era: the role of scores.
Mantegazza, Valentina; Badagliacca, Roberto; Nodari, Savina; Parati, Gianfranco; Lombardi, Carolina; Di Somma, Salvatore; Carluccio, Erberto; Dini, Frank Lloyd; Correale, Michele; Magrì, Damiano; Agostoni, Piergiuseppe
2016-08-01
Heart failure is a widespread syndrome involving several organs, still characterized by high mortality and morbidity, and whose clinical course is heterogeneous and hardly predictable.In this scenario, the assessment of heart failure prognosis represents a fundamental step in clinical practice. A single parameter is always unable to provide a very precise prognosis. Therefore, risk scores based on multiple parameters have been introduced, but their clinical utility is still modest. In this review, we evaluated several prognostic models for acute, right, chronic, and end-stage heart failure based on multiple parameters. In particular, for chronic heart failure we considered risk scores essentially based on clinical evaluation, comorbidities analysis, baroreflex sensitivity, heart rate variability, sleep disorders, laboratory tests, echocardiographic imaging, and cardiopulmonary exercise test parameters. What is at present established is that a single parameter is not sufficient for an accurate prediction of prognosis in heart failure because of the complex nature of the disease. However, none of the scoring systems available is widely used, being in some cases complex, not user-friendly, or based on expensive or not easily available parameters. We believe that multiparametric scores for risk assessment in heart failure are promising but their widespread use needs to be experienced.
How and why of orthodontic bond failures: An in vivo study
Vijayakumar, R. K.; Jagadeep, Raju; Ahamed, Fayyaz; Kanna, Aprose; Suresh, K.
2014-01-01
Introduction: The bonding of orthodontic brackets and their failure rates by both direct and in-direct procedures are well-documented in orthodontic literature. Over the years different adhesive materials and various indirect bonding transfer procedures have been compared and evaluated for bond failure rates. The aim of our study is to highlight the use of a simple, inexpensive and ease of manipulation of a single thermo-plastic transfer tray and the use the of a single light cure adhesive to evaluate the bond failure rates in clinical situations. Materials and Methods: A total of 30 patients were randomly divided into two groups (Group A and Group B). A split-mouth study design was used, for, both the groups so that they were distributed equally with-out bias. After initial prophylaxis, both the procedures were done as per manufactures instructions. All patients were initially motivated and reviewed for bond failures rates for 6 months. Results: Bond failure rates were assessed for over-all direct and indirect procedures, anterior and posterior arches, and for individual tooth. Z-test was used for statistically analyzing, the normal distribution of the sample in a spilt mouth study. The results of the two groups were compared and P value was calculated using Z-proportion test to assess the significance of the bond failure. Conclusion: Over-all bond failure was more for direct bonding. Anterior bracket failure was more in-direct bonding than indirect procedure, which showed more posterior bracket failures. In individual tooth bond failure, mandibular incisor, and premolar brackets showed more failure, followed by maxillary premolars and canines. PMID:25210392
Jeong, Yechan; Jin, Bora; Lee, Hye Won; Park, Hye Jung; Park, Jun Yong; Kim, Do Young; Han, Kwang-Hyub; Ahn, Sang Hoon; Kim, Seungtaek
2018-05-16
Daclatasvir plus asunaprevir (DCV+ASV) treatment is an all-oral direct-acting antiviral (DAA) therapy for the genotype 1b HCV-infected patients. In this study, we investigated how resistance-associated substitutions (RASs) evolved after treatment failures and assessed the effect of those substitutions on viral fitness. Sequencing of NS5A and NS3 revealed typical RASs after treatment failures. Interestingly, the RASs of NS3 reverted to the wild-type amino acid within one year after treatment failures. However, the RASs of NS5A were stable and did not change. The effect of NS5A and NS3 RASs on viral RNA replication was assessed after mutagenic substitution in the genotype 1b HCV RNA. Among the single substitutions, the effect of D168V was more substantial than the others and the effect of the triple mutant combination (D168V+L31V+Y93H) was the most severe. The RAS at NS5A Y93 affected both viral RNA replication and virus production. Finally, the effect of trans-complementation of NS5A was demonstrated in our co-transfection experiments and these results suggest that such a trans-complementation effect of NS5A may help maintain the NS5A RASs for a long time even after cessation of the DAA treatment. In conclusion, the results from this investigation would help understand the emergence and persistence of RASs. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
An Updated Perspective of Single Event Gate Rupture and Single Event Burnout in Power MOSFETs
NASA Astrophysics Data System (ADS)
Titus, Jeffrey L.
2013-06-01
Studies over the past 25 years have shown that heavy ions can trigger catastrophic failure modes in power MOSFETs [e.g., single-event gate rupture (SEGR) and single-event burnout (SEB)]. In 1996, two papers were published in a special issue of the IEEE Transaction on Nuclear Science [Johnson, Palau, Dachs, Galloway and Schrimpf, “A Review of the Techniques Used for Modeling Single-Event Effects in Power MOSFETs,” IEEE Trans. Nucl. Sci., vol. 43, no. 2, pp. 546-560, April. 1996], [Titus and Wheatley, “Experimental Studies of Single-Event Gate Rupture and Burnout in Vertical Power MOSFETs,” IEEE Trans. Nucl. Sci., vol. 43, no. 2, pp. 533-545, Apr. 1996]. Those two papers continue to provide excellent information and references with regard to SEB and SEGR in vertical planar MOSFETs. This paper provides updated references/information and provides an updated perspective of SEB and SEGR in vertical planar MOSFETs as well as provides references/information to other device types that exhibit SEB and SEGR effects.
Wagner, Mathilde; Corcuera-Solano, Idoia; Lo, Grace; Esses, Steven; Liao, Joseph; Besa, Cecilia; Chen, Nelson; Abraham, Ginu; Fung, Maggie; Babb, James S; Ehman, Richard L; Taouli, Bachir
2017-08-01
Purpose To assess the determinants of technical failure of magnetic resonance (MR) elastography of the liver in a large single-center study. Materials and Methods This retrospective study was approved by the institutional review board. Seven hundred eighty-one MR elastography examinations performed in 691 consecutive patients (mean age, 58 years; male patients, 434 [62.8%]) in a single center between June 2013 and August 2014 were retrospectively evaluated. MR elastography was performed at 3.0 T (n = 443) or 1.5 T (n = 338) by using a gradient-recalled-echo pulse sequence. MR elastography and anatomic image analysis were performed by two observers. Additional observers measured liver T2* and fat fraction. Technical failure was defined as no pixel value with a confidence index higher than 95% and/or no apparent shear waves imaged. Logistic regression analysis was performed to assess potential predictive factors of technical failure of MR elastography. Results The technical failure rate of MR elastography at 1.5 T was 3.5% (12 of 338), while it was higher, 15.3% (68 of 443), at 3.0 T. On the basis of univariate analysis, body mass index, liver iron deposition, massive ascites, use of 3.0 T, presence of cirrhosis, and alcoholic liver disease were all significantly associated with failure of MR elastography (P < .004); but on the basis of multivariable analysis, only body mass index, liver iron deposition, massive ascites, and use of 3.0 T were significantly associated with failure of MR elastography (P < .004). Conclusion The technical failure rate of MR elastography with a gradient-recalled-echo pulse sequence was low at 1.5 T but substantially higher at 3.0 T. Massive ascites, iron deposition, and high body mass index were additional independent factors associated with failure of MR elastography of the liver with a two-dimensional gradient-recalled-echo pulse sequence. © RSNA, 2017.
Strategies for achieving global collective action on antimicrobial resistance
Caleo, Grazia M; Daulaire, Nils; Elbe, Stefan; Matsoso, Precious; Mossialos, Elias; Rizvi, Zain; Røttingen, John-Arne
2015-01-01
Abstract Global governance and market failures mean that it is not possible to ensure access to antimicrobial medicines of sustainable effectiveness. Many people work to overcome these failures, but their institutions and initiatives are insufficiently coordinated, led and financed. Options for promoting global collective action on antimicrobial access and effectiveness include building institutions, crafting incentives and mobilizing interests. No single option is sufficient to tackle all the challenges associated with antimicrobial resistance. Promising institutional options include monitored milestones and an inter-agency task force. A global pooled fund could be used to craft incentives and a special representative nominated as an interest mobilizer. There are three policy components to the problem of antimicrobials – ensuring access, conservation and innovation. To address all three components, the right mix of options needs to be matched with an effective forum and may need to be supported by an international legal framework. PMID:26668439
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mossahebi, S; Feigenberg, S; Nichols, E
Purpose: GammaPod™, the first stereotactic radiotherapy device for early stage breast cancer treatment, has been recently installed and commissioned at our institution. A multidisciplinary working group applied the failure mode and effects analysis (FMEA) approach to perform a risk analysis. Methods: FMEA was applied to the GammaPod™ treatment process by: 1) generating process maps for each stage of treatment; 2) identifying potential failure modes and outlining their causes and effects; 3) scoring the potential failure modes using the risk priority number (RPN) system based on the product of severity, frequency of occurrence, and detectability (ranging 1–10). An RPN of highermore » than 150 was set as the threshold for minimal concern of risk. For these high-risk failure modes, potential quality assurance procedures and risk control techniques have been proposed. A new set of severity, occurrence, and detectability values were re-assessed in presence of the suggested mitigation strategies. Results: In the single-day image-and-treat workflow, 19, 22, and 27 sub-processes were identified for the stages of simulation, treatment planning, and delivery processes, respectively. During the simulation stage, 38 potential failure modes were found and scored, in terms of RPN, in the range of 9-392. 34 potential failure modes were analyzed in treatment planning with a score range of 16-200. For the treatment delivery stage, 47 potential failure modes were found with an RPN score range of 16-392. The most critical failure modes consisted of breast-cup pressure loss and incorrect target localization due to patient upper-body alignment inaccuracies. The final RPN score of these failure modes based on recommended actions were assessed to be below 150. Conclusion: FMEA risk analysis technique was applied to the treatment process of GammaPod™, a new stereotactic radiotherapy technology. Application of systematic risk analysis methods is projected to lead to improved quality of GammaPod™ treatments. Ying Niu and Cedric Yu are affiliated with Xcision Medical Systems.« less
Failure analysis of single-bolted joint for lightweight composite laminates and metal plate
NASA Astrophysics Data System (ADS)
Li, Linjie; Qu, Junli; Liu, Xiangdong
2018-01-01
A three-dimensional progressive damage model was developed in ANSYS to predict the damage accumulation of single bolted joint in composite laminates under in-plane tensile loading. First, we describe the formulation and algorithm of this model. Second, we calculate the failure loads of the joint in fibre reinforced epoxy laminated composite plates and compare it with the experiment results, which validates that our model can appropriately simulate the ultimate tensile strength of the joints and the whole process of failure of structure. Finally, this model is applied to study the failure process of the light-weight composite material (USN125). The study also has a great potential to provide a strong basis for bolted joints design in composite Laminates as well as a simple tool for comparing different laminate geometries and bolt arrangements.
Compression failure mechanisms of single-ply, unidirectional, carbon-fiber composites
NASA Technical Reports Server (NTRS)
Ha, Jong-Bae; Nairn, John A.
1992-01-01
A single-ply composite compression test was used to study compression failure mechanisms as a function of fiber type, matrix type, and interfacial strength. Composites made with low- and intermediate-modulus fibers (Hercules AS4 and IM7) in either an epoxy (Hercules 3501-6) or a thermoplastic (ULTEM and LARC-TPI) matrix failed by kink banding and out-of-plane slip. The failures proceeded by rapid and catastrophic damage propagation across the specimen width. Composites made with high-modulus fibers (Hercules HMS4/3501-6) had a much lower compression strength. Their failures were characterized by kink banding and longitudinal splitting. The damage propagated slowly across the specimen width. Composites made with fibers treated to give low interfacial strength had low compression strength. These composites typically failed near the specimen ends and had long kink bands.
Improvement of Progressive Damage Model to Predicting Crashworthy Composite Corrugated Plate
NASA Astrophysics Data System (ADS)
Ren, Yiru; Jiang, Hongyong; Ji, Wenyuan; Zhang, Hanyu; Xiang, Jinwu; Yuan, Fuh-Gwo
2018-02-01
To predict the crashworthy composite corrugated plate, different single and stacked shell models are evaluated and compared, and a stacked shell progressive damage model combined with continuum damage mechanics is proposed and investigated. To simulate and predict the failure behavior, both of the intra- and inter- laminar failure behavior are considered. The tiebreak contact method, 1D spot weld element and cohesive element are adopted in stacked shell model, and a surface-based cohesive behavior is used to capture delamination in the proposed model. The impact load and failure behavior of purposed and conventional progressive damage models are demonstrated. Results show that the single shell could simulate the impact load curve without the delamination simulation ability. The general stacked shell model could simulate the interlaminar failure behavior. The improved stacked shell model with continuum damage mechanics and cohesive element not only agree well with the impact load, but also capture the fiber, matrix debonding, and interlaminar failure of composite structure.
Evaluation of commercial ADC radiation tolerance for accelerator experiments
Chen, K.; Chen, H.; Kierstead, J.; ...
2015-08-17
Electronic components used in high energy physics experiments are subjected to a radiation background composed of high energy hadrons, mesons and photons. These particles can induce permanent and transient effects that affect the normal device operation. Ionizing dose and displacement damage can cause chronic damage which disable the device permanently. Transient effects or single event effects are in general recoverable with time intervals that depend on the nature of the failure. The magnitude of these effects is technology dependent with feature size being one of the key parameters. Analog to digital converters are components that are frequently used in detectormore » front end electronics, generally placed as close as possible to the sensing elements to maximize signal fidelity. We report on radiation effects tests conducted on 17 commercially available analog to digital converters and extensive single event effect measurements on specific twelve and fourteen bit ADCs that presented high tolerance to ionizing dose. We discuss mitigation strategies for single event effects (SEE) for their use in the large hadron collider environment.« less
Spotlight on valsartan-sacubitril fixed-dose combination for heart failure: the evidence to date.
Vilela-Martin, José Fernando
2016-01-01
Heart failure is a global problem with elevated prevalence, and it is associated with substantial cardiovascular morbidity and mortality. Treating heart-failure patients has been a very challenging task. This review highlights the main pharmacological developments in the field of heart failure with reduced ejection fraction, giving emphasis to a drug that has a dual-acting inhibition of the neprilysin and renin-angiotensin-aldosterone system. Neprilysin is an enzyme that participates in the breakdown of biologically active natriuretic peptides and several other vasoactive compounds. The inhibition of neprilysin has been a therapeutic target for several drugs tested in cardiovascular disease, mainly for heart failure and/or hypertension. However, side effects and a lack of efficacy led to discontinuation of their development. LCZ696 is a first-in-class neprilysin- and angiotensin-receptor inhibitor that has been developed for use in heart failure. This drug is composed of two molecular moieties in a single crystalline complex: a neprilysin-inhibitor prodrug (sacubitril) and the angiotensin-receptor blocker (valsartan). The PARADIGM-HF trial demonstrated that this drug was superior to an angiotensin-converting enzyme inhibitor (enalapril) in reducing mortality in patients with heart failure with reduced ejection fraction. The ability to block the angiotensin receptor and augment the endogenous natriuretic peptide system provides a distinctive mechanism of action in cardiovascular disease.
Spotlight on valsartan–sacubitril fixed-dose combination for heart failure: the evidence to date
Vilela-Martin, José Fernando
2016-01-01
Heart failure is a global problem with elevated prevalence, and it is associated with substantial cardiovascular morbidity and mortality. Treating heart-failure patients has been a very challenging task. This review highlights the main pharmacological developments in the field of heart failure with reduced ejection fraction, giving emphasis to a drug that has a dual-acting inhibition of the neprilysin and renin–angiotensin–aldosterone system. Neprilysin is an enzyme that participates in the breakdown of biologically active natriuretic peptides and several other vasoactive compounds. The inhibition of neprilysin has been a therapeutic target for several drugs tested in cardiovascular disease, mainly for heart failure and/or hypertension. However, side effects and a lack of efficacy led to discontinuation of their development. LCZ696 is a first-in-class neprilysin- and angiotensin-receptor inhibitor that has been developed for use in heart failure. This drug is composed of two molecular moieties in a single crystalline complex: a neprilysin-inhibitor prodrug (sacubitril) and the angiotensin-receptor blocker (valsartan). The PARADIGM-HF trial demonstrated that this drug was superior to an angiotensin-converting enzyme inhibitor (enalapril) in reducing mortality in patients with heart failure with reduced ejection fraction. The ability to block the angiotensin receptor and augment the endogenous natriuretic peptide system provides a distinctive mechanism of action in cardiovascular disease. PMID:27274196
Cavopulmonary assist: (Em)powering the univentricular Fontan circulation
Rodefeld, Mark D; Frankel, Steven H; Giridharan, Guruprasad A
2011-01-01
Since the Fontan/Kreutzer procedure was introduced, evolutionary clinical advances via a staged surgical reconstructive approach have markedly improved outcomes for patients with functional single ventricle. However, significant challenges remain. Early stage mortality risk seems impenetrable. Serious morbidities - construed as immutable consequences of palliation - have hardly been addressed. Late functional status is increasingly linked to pathophysiologic consequences of prior staged procedures. As more single ventricle patients survive into adulthood, Fontan failure is emerging as an intractable problem for which there is no targeted therapy. Incremental solutions to address these ongoing problems have not had a measurable impact. Therefore, a fundamental reconsideration of the overall approach is reasonable and warranted. The ability to provide a modest pressure boost (2-6 mmHg) to existing blood flow at the total cavopulmonary connection can effectively restore more stable biventricular status. This would impact not only treatment of late Fontan failure, but also facilitate early surgical repair. A realistic means to provide such a pressure boost has never been apparent. Recent advances are beginning to unravel the unique challenges which must be addressed to realize this goal, with promise to open single ventricle palliation to new therapeutic vistas. PMID:21444049
A dislocation-based crystal plasticity framework for dynamic ductile failure of single crystals
NASA Astrophysics Data System (ADS)
Nguyen, Thao; Luscher, D. J.; Wilkerson, J. W.
2017-11-01
A framework for dislocation-based viscoplasticity and dynamic ductile failure has been developed to model high strain rate deformation and damage in single crystals. The rate-dependence of the crystal plasticity formulation is based on the physics of relativistic dislocation kinetics suited for extremely high strain rates. The damage evolution is based on the dynamics of void growth, which are governed by both micro-inertia as well as dislocation kinetics and dislocation substructure evolution. An averaging scheme is proposed in order to approximate the evolution of the dislocation substructure in both the macroscale as well as its spatial distribution at the microscale. Additionally, a concept of a single equivalent dislocation density that effectively captures the collective influence of dislocation density on all active slip systems is proposed here. Together, these concepts and approximations enable the use of semi-analytic solutions for void growth dynamics developed in (Wilkerson and Ramesh, 2014), which greatly reduce the computational overhead that would otherwise be required. The resulting homogenized framework has been implemented into a commercially available finite element package, and a validation study against a suite of direct numerical simulations was carried out.
Dysregulated microRNA Activity in Shwachman-Diamond Syndrome
2016-09-01
define transcriptional signatures of bone marrow failure in SDS using single cell RNA -seq of patient cells. We will analyze these datasets to test the...microRNA expression profiles from HSPCs to be overlaid onto mRNA profiles. 15. SUBJECT TERMS Single cell RNA -seq; bone marrow failure; hematopoiesis...myelopoiesis; targeted RNA -seq 16. SECURITY CLASSIFICATION OF: U 17. LIMITATION OF ABSTRACT 18. NUMBER OF PAGES 19a. NAME OF RESPONSIBLE PERSON
Hwee, Darren T; Kennedy, Adam R; Hartman, James J; Ryans, Julie; Durham, Nickie; Malik, Fady I; Jasper, Jeffrey R
2015-04-01
Heart failure-mediated skeletal myopathy, which is characterized by muscle atrophy and muscle metabolism dysfunction, often manifests as dyspnea and limb muscle fatigue. We have previously demonstrated that increasing Ca(2+) sensitivity of the sarcomere by a small-molecule fast skeletal troponin activator improves skeletal muscle force and exercise performance in healthy rats and models of neuromuscular disease. The objective of this study was to investigate the effect of a novel fast skeletal troponin activator, CK-2127107 (2-aminoalkyl-5-N-heteroarylpyrimidine), on skeletal muscle function and exercise performance in rats exhibiting heart failure-mediated skeletal myopathy. Rats underwent a left anterior descending coronary artery ligation, resulting in myocardial infarction and a progressive decline in cardiac function [left anterior descending coronary artery heart failure (LAD-HF)]. Compared with sham-operated control rats, LAD-HF rat hindlimb and diaphragm muscles exhibited significant muscle atrophy. Fatigability was increased during repeated in situ isokinetic plantar flexor muscle contractions. CK-2127107 produced a leftward shift in the force-Ca(2+) relationship of skinned, single diaphragm, and extensor digitorum longus fibers. Exercise performance, which was assessed by rotarod running, was lower in vehicle-treated LAD-HF rats than in sham controls (116 ± 22 versus 193 ± 31 seconds, respectively; mean ± S.E.M.; P = 0.04). In the LAD-HF rats, a single oral dose of CK-2127107 (10 mg/kg p.o.) increased running time compared with vehicle treatment (283 ± 47 versus 116 ± 22 seconds; P = 0.0004). In summary, CK-2127107 substantially increases exercise performance in this heart failure model, suggesting that modulation of skeletal muscle function by a fast skeletal troponin activator may be a useful therapeutic in heart failure-associated exercise intolerance. Copyright © 2015 by The American Society for Pharmacology and Experimental Therapeutics.
Modification of the contact surfaces for improving the puncture resistance of laminar structures.
Wang, Pengfei; Yang, Jinglei; Li, Xin; Liu, Mao; Zhang, Xin; Sun, Dawei; Bao, Chenlu; Gao, Guangfa; Yahya, Mohd Yazid; Xu, Songlin
2017-07-26
Uncovering energy absorption and surface effects of various penetrating velocities on laminar structures is essential for designing protective structures. In this study, both quasi-static and dynamic penetration tests were systematical conducted on the front surfaces of metal sheets coated with a graphene oxide (GO) solution and other media. The addition of a GO fluid film to the front impact surface aided in increasing the penetration strength, improving the failure extension and dissipating additional energy under a wide-range of indentation velocity, from 3.33 × 10 -5 m/s to 4.42 m/s. The coated -surfaces improved the specific energy dissipation by approximately 15~40% relative to the dry-contact configuration for both single-layer and double-layer configurations, and specific energy dissipations of double-layer configurations were 20~30% higher than those of the single-layer configurations. This treatment provides a facile strategy in changing the contact state for improving the failure load and dissipate additional energy.
Peng, D; Wang, S P; Zhao, D H; Fan, Q C; Shu, J; Liu, J H
2018-05-08
Objective: To explore the effect of hyperuricemia on prognosis in patients with heart failure of coronary heart disease (CHD) after revascularization. Methods: A single-center retrospective study of all subjects who underwent percutaneous coronary intervention (PCI) or coronary artery bypass grafting (CABG) as revascularization for CHD at Beijing Anzhen Hospital, Capital Medical University, between January 2005 and December 2014 was performed.Patients were divided into two groups by with or without hyperuricemia.The average follow-up was 1 818 d. Results: The Logistic regression analysis revealed that hyperuricemia was independent risk factors of readmission of heart failure( P =0.018, OR =1.499, 95% CI 1.071-2.098). The Cox regression analysis revealed that hyperuricemia was independent risk factor of all-cause mortality( P =0.002, RR =1.520, 95% CI 1.166-1.982), cardiovascular ( CV ) mortality( P =0.001, RR =1.811, 95% CI 1.279-2.566), heart failure mortality( P =0.006, RR =2.151, 95% CI 1.247-3.711). Conclusions: There is negative correlation between level of uric acid and left ventricular ejection fraction (LVEF). The patients with heart failure of coronary heart disease complicated with hyperuricemia have high risk of readmission of heart failure, all-cause mortality, CV mortality andheart failure mortality than patients with normal uric acid level. Hyperuricemia is an independent risk factor for patients with heart failure of coronary heart disease after revascularization.
Patient Characteristics Predicting Readmission Among Individuals Hospitalized for Heart Failure
O'Connor, Melissa; Murtaugh, Christopher M.; Shah, Shivani; Barrón-Vaya, Yolanda; Bowles, Kathryn H.; Peng, Timothy R.; Zhu, Carolyn W.; Feldman, Penny H.
2015-01-01
Heart failure is difficult to manage and increasingly common with many individuals experiencing frequent hospitalizations. Little is known about patient factors consistently associated with hospital readmission. A literature review was conducted to identify heart failure patient characteristics, measured before discharge, that contribute to variation in hospital readmission rates. Database searches yielded 950 potential articles, of which 34 studies met inclusion criteria. Patient characteristics generally have a very modest effect on all-cause or heart failure–related readmission within 7 to 180 days of index hospital discharge. A range of cardiac diseases and other comorbidities only minimally increase readmission rates. No single patient characteristic stands out as a key contributor across multiple studies underscoring the challenge of developing successful interventions to reduce readmissions. Interventions may need to be general in design with the specific intervention depending on each patient's unique clinical profile. PMID:26180045
Master/slave clock arrangement for providing reliable clock signal
NASA Technical Reports Server (NTRS)
Abbey, Duane L. (Inventor)
1977-01-01
The outputs of two like frequency oscillators are combined to form a single reliable clock signal, with one oscillator functioning as a slave under the control of the other to achieve phase coincidence when the master is operative and in a free-running mode when the master is inoperative so that failure of either oscillator produces no effect on the clock signal.
MEMS Reliability Assurance Activities at JPL
NASA Technical Reports Server (NTRS)
Kayali, S.; Lawton, R.; Stark, B.
2000-01-01
An overview of Microelectromechanical Systems (MEMS) reliability assurance and qualification activities at JPL is presented along with the a discussion of characterization of MEMS structures implemented on single crystal silicon, polycrystalline silicon, CMOS, and LIGA processes. Additionally, common failure modes and mechanisms affecting MEMS structures, including radiation effects, are discussed. Common reliability and qualification practices contained in the MEMS Reliability Assurance Guideline are also presented.
Mikeladze, Maia; Hedrington, Maka S.; Joy, Nino; Tate, Donna B.; Younk, Lisa M.; Davis, Ian
2016-01-01
We tested the hypothesis that acute administration of oral dehydroepiandrosterone (DHEA) during episodes of repeated hypoglycemia can prevent the development of hypoglycemia-associated neuroendocrine and autonomic failure in healthy humans. Twenty-seven individuals (16 men, 11 women) participated in two separate randomized, single-blind, 2-day protocols. Day 1 consisted of morning and afternoon 2-h hypoglycemic clamps (2.9 mmol/L) with 800 mg of DHEA or placebo administered before each clamp. Day 2 consisted of a single 2-h hypoglycemic clamp (2.9 mmol/L) following either DHEA (1,600 mg) or placebo. A 3-tritiated glucose was used to determine glucose kinetics during hypoglycemia on day 2. Antecedent hypoglycemia with placebo resulted in significant reductions of epinephrine, norepinephrine, glucagon, growth hormone, cortisol, endogenous glucose production, and lipolytic and symptom responses. During hypoglycemia on day 2, DHEA prevented blunting of all neuroendocrine, autonomic nervous system (ANS), metabolic, and symptom counterregulatory responses following hypoglycemia on day 1. In summary, DHEA can acutely preserve a wide range of key neuroendocrine, ANS, and metabolic counterregulatory homeostatic responses during repeated hypoglycemia. We conclude that DHEA may have acute effects to protect against hypoglycemia-associated neuroendocrine and autonomic failure in healthy humans. PMID:27486235
Leem, Jungtae; Lee, Seung Min Kathy; Park, Jun Hyeong; Lee, Suji; Chung, Hyemoon; Lee, Jung Myung; Kim, Weon; Lee, Sanghoon; Woo, Jong Shin
2017-07-11
The purpose of this trial is to evaluate the effectiveness and safety of electroacupuncture in the treatment of acute decompensated heart failure compared with sham electroacupuncture. This protocol is for a randomized, sham controlled, patient- and assessor-blinded, parallel group, single center clinical trial that can overcome the limitations of previous trials examining acupuncture and heart failure. Forty-four acute decompensated heart failure patients admitted to the cardiology ward will be randomly assigned into the electroacupuncture treatment group (n = 22) or the sham electroacupuncture control group (n = 22). Participants will receive electroacupuncture treatment for 5 days of their hospital stay. The primary outcome of this study is the difference in total diuretic dose between the two groups during hospitalization. On the day of discharge, follow-up heart rate variability, routine blood tests, cardiac biomarkers, high-sensitivity C-reactive protein (hs-CRP) level, and N-terminal pro b-type natriuretic peptide (NT-pro BNP) level will be assessed. Four weeks after discharge, hs-CRP, NT-pro BNP, heart failure symptoms, quality of life, and a pattern identification questionnaire will be used for follow-up analysis. Six months after discharge, major cardiac adverse events and cardiac function measured by echocardiography will be assessed. Adverse events will be recorded during every visit. The result of this clinical trial will offer evidence of the effectiveness and safety of electroacupuncture for acute decompensated heart failure. Clinical Research Information Service: KCT0002249 .
Bai, Wenxia; Wang, Shudong; An, Shanshan; Guo, Mengjie; Gong, Guangming; Liu, Wenya; Ma, Shaoxin; Li, Xin; Fu, Jihua; Yao, Wenbing
2018-01-01
This study aimed to investigate the effect of single and combination therapy using chitosan (K), gynostemma (J), and motherwort (Y) on an experimental rat model of chronic renal failure (CRF) induced by adenine and the underlying mechanisms. CRF rats were treated with individual or combinational therapy with two or three of these agents. Biochemical indicators showed that the levels of blood urea nitrogen, creatinine and uric acid decreased and the levels of albumin and hemoglobin increased by single or combination therapy of these drugs. Drug treatment also decreased oxidative stress damage of renal tissues in CRF rats. Histopathological lesions were attenuated in each drug treatment group by various degrees. Additionally, drug treatment affected the expression of extracellular matrix (ECM) proteins including plasminogen activator inhibitor 1, collagen I, matrix metalloprotease-1, and tissue inhibitor of metalloproteinases 1. In particular, the combination therapy of K, J, and Y was superior to the respective monotherapy, which supported the prescription of KJY combination. We further studied the inhibitory effect of KJY on LPS-induced inflammation in RAW264.7 macrophages. The results showed that KJY inhibited LPS-induced secretion of inflammatory cytokines (Interferon-gamma, Interleukin-1 Beta, chemokine (C-X-C motif) ligand 10, cyclooxygenase-2 and Tumor necrosis factor-α in RAW264.7 macrophages. Combination therapy of KJY suppressed the protein expression of Cyclooxygenase-2 and inducible nitric oxide synthase in vivo and in vitro. Further study indicated that KJY inhibited STAT1 activation by down regulating p-STAT1 to exert anti-inflammatory effect and improve renal function in rats with chronic renal failure. PMID:29643988
Access to pain treatment as a human right.
Lohman, Diederik; Schleifer, Rebecca; Amon, Joseph J
2010-01-20
Almost five decades ago, governments around the world adopted the 1961 Single Convention on Narcotic Drugs which, in addition to addressing the control of illicit narcotics, obligated countries to work towards universal access to the narcotic drugs necessary to alleviate pain and suffering. Yet, despite the existence of inexpensive and effective pain relief medicines, tens of millions of people around the world continue to suffer from moderate to severe pain each year without treatment. Significant barriers to effective pain treatment include: the failure of many governments to put in place functioning drug supply systems; the failure to enact policies on pain treatment and palliative care; poor training of healthcare workers; the existence of unnecessarily restrictive drug control regulations and practices; fear among healthcare workers of legal sanctions for legitimate medical practice; and the inflated cost of pain treatment. These barriers can be understood not only as a failure to provide essential medicines and relieve suffering but also as human rights abuses. According to international human rights law, countries have to provide pain treatment medications as part of their core obligations under the right to health; failure to take reasonable steps to ensure that people who suffer pain have access to adequate pain treatment may result in the violation of the obligation to protect against cruel, inhuman and degrading treatment.
Durham, Myra E; Sod, Gary A; Riggs, Laura M; Mitchell, Colin F
2015-02-01
To compare the monotonic biomechanical properties of a broad 4.5 mm limited contact-dynamic compression plate (LC-DCP) fixation secured with hydroxyapatite (HA) coated cortical bone screws (HA-LC-DCP) versus uncoated cortical bone screws (AO-LC-DCP) to repair osteotomized equine 3rd metacarpal (MC3) bones. Experimental. Adult equine cadaveric MC3 bones (n = 12 pair). Twelve pairs of equine MC3 were divided into 3 test groups (4 pairs each) for: (1) 4 point bending single cycle to failure testing; (2) 4 point bending cyclic fatigue testing; and (3) torsional single cycle to failure testing. For the HA-LC-DCP-MC3 construct, an 8-hole broad LC-DCP (Synthes Ltd, Paoli, PA) was secured on the dorsal surface of each randomly selected MC3 bone with a combination of four 5.5 mm and four 4.5 mm HA-coated cortical screws. For the AO-LC-DCP-MC3 construct, an 8-hole 4.5 mm broad LC-DCP was secured on the dorsal surface of the contralateral MC3 bone with a combination of four 5.5 mm and four 4.5 mm uncoated cortical screws. All MC3 bones had mid-diaphyseal osteotomies. Mean test variable values for each method were compared using a paired t-test within each group. Significance was set at P < .05. Mean yield load, yield bending moment, composite rigidity, failure load, and failure bending moment, under 4 point bending, single cycle to failure, of the HA-LC-DCP fixation were significantly greater than those of the AO-LC-DCP fixation. Mean ± SD values for the HA-LC-DCP and the AO-LC-DCP fixation techniques, respectively, in single cycle to failure under 4 point bending were: yield load, 26.7 ± 2.15 and 16.3 ± 1.38 kN; yield bending moment, 527.4 ± 42.4 and 322.9 ± 27.2 N-m; composite rigidity, 5306 ± 399 and 3003 ± 300 N-m/rad; failure load, 40.6 ± 3.94 and 26.5 ± 2.52 kN; and failure bending moment, 801.9 ± 77.9 and 522.9 ± 52.2 N-m. Mean cycles to failure in 4 point bending of the HA-LC-DCP fixation (116,274 ± 13,211) was significantly greater than that of the AO-LC-DCP fixation 47,619 ± 6580. Mean yield load, mean composite rigidity, and mean failure load under torsional testing, single cycle to failure was significantly greater for the broad HA-LC-DCP fixation compared with the AO-LC-DCP fixation. In single cycle to failure under torsion, mean ± SD values for the HA-LC-DCP and the AO-LC-DCP fixation techniques, respectively, were: yield load, 101.3 ± 14.68 and 70.54 ± 10.20 N-m; composite rigidity, 437.9 ± 32.9 and 220.7 ± 17.6 N-m/rad; and failure load: 105.7 ± 15.5 and 75.28 ± 10.1 N-m. HA-LC-DCP was superior to AO-LC-DCP in resisting the static overload forces (palmarodorsal 4 point bending and torsional) and in resisting cyclic fatigue under palmarodorsal 4 point bending. © Copyright 2014 by The American College of Veterinary Surgeons.
Ghavami, Behnam; Raji, Mohsen; Pedram, Hossein
2011-08-26
Carbon nanotube field-effect transistors (CNFETs) show great promise as building blocks of future integrated circuits. However, synthesizing single-walled carbon nanotubes (CNTs) with accurate chirality and exact positioning control has been widely acknowledged as an exceedingly complex task. Indeed, density and chirality variations in CNT growth can compromise the reliability of CNFET-based circuits. In this paper, we present a novel statistical compact model to estimate the failure probability of CNFETs to provide some material and process guidelines for the design of CNFETs in gigascale integrated circuits. We use measured CNT spacing distributions within the framework of detailed failure analysis to demonstrate that both the CNT density and the ratio of metallic to semiconducting CNTs play dominant roles in defining the failure probability of CNFETs. Besides, it is argued that the large-scale integration of these devices within an integrated circuit will be feasible only if a specific range of CNT density with an acceptable ratio of semiconducting to metallic CNTs can be adjusted in a typical synthesis process.
Microseismic Signature of Magma Failure: Testing Failure Forecast in Heterogeneous Material
NASA Astrophysics Data System (ADS)
Vasseur, J.; Lavallee, Y.; Hess, K.; Wassermann, J. M.; Dingwell, D. B.
2012-12-01
Volcanoes exhibit a range of seismic precursors prior to eruptions. This range of signals derive from different processes, which if quantified, may tell us when and how the volcano will erupt: effusively or explosively. This quantification can be performed in laboratory. Here we investigated the signals associated with the deformation and failure of single-phase silicate liquids compare to mutli-phase magmas containing pores and crystals as heterogeneities. For the past decades, magmas have been simplified as viscoelastic fluids with grossly predictable failure, following an analysis of the stress and strain rate conditions in volcanic conduits. Yet it is clear that the way magmas fail is not unique and evidences increasingly illustrate the role of heterogeneities in the process of magmatic fragmentation. In such multi-phase magmas, failure cannot be predicted using current rheological laws. Microseismicity, as detected in the laboratory by analogous Acoustic Emission (AE), can be used to monitor fracture initiation and propagation, and thus provides invaluable information to characterise the process of brittle failure underlying explosive eruptions. Tri-axial press experiments on different synthetised and natural glass samples have been performed to investigate the acoustic signature of failure. We observed that the failure of single-phase liquids occurs without much strain and is preceded by the constant nucleation, propagation and coalescence of cracks as demonstrated by the monitored AE. In contrast, the failure of multi-phase magmas depends on the applied stress and is strain dependent. The path dependence of magma failure is nonetheless accompanied by supra exponential acceleration in released AEs. Analysis of the released AEs following material Failure Forecast Method (FFM) suggests that the predicability of failure is enhanced by the presence of heterogeneities in magmas. We discuss our observations in terms of volcanic scenarios.
Fretting Stresses in Single Crystal Superalloy Turbine Blade Attachments
NASA Technical Reports Server (NTRS)
Arakere, Nagaraj K.; Swanson, Gregory
2000-01-01
Single crystal nickel base superalloy turbine blades are being utilized in rocket engine turbopumps and turbine engines because of their superior creep, stress rupture, melt resistance and thermomechanical fatigue capabilities over polycrystalline alloys. Currently the most widely used single crystal nickel base turbine blade superalloys are PWA 1480/1493 and PWA 1484. These alloys play an important role in commercial, military and space propulsion systems. High Cycle Fatigue (HCF) induced failures in aircraft gas turbine and rocket engine turbopump blades is a pervasive problem. Blade attachment regions are prone to fretting fatigue failures. Single crystal nickel base superalloy turbine blades are especially prone to fretting damage because the subsurface shear stresses induced by fretting action at the attachment regions can result in crystallographic initiation and crack growth along octahedral planes. Furthermore, crystallographic crack growth on octahedral planes under fretting induced mixed mode loading can be an order of magnitude faster than under pure mode I loading. This paper presents contact stress evaluation in the attachment region for single crystal turbine blades used in the NASA alternate Advanced High Pressure Fuel Turbo Pump (HPFTP/AT) for the Space Shuttle Main Engine (SSME). Single crystal materials have highly orthotropic properties making the position of the crystal lattice relative to the part geometry a significant factor in the overall analysis. Blades and the attachment region are modeled using a large-scale 3D finite element (FE) model capable of accounting for contact friction, material orthotrophy, and variation in primary and secondary crystal orientation. Contact stress analysis in the blade attachment regions is presented as a function of coefficient of friction and primary and secondary crystal orientation, Stress results are used to discuss fretting fatigue failure analysis of SSME blades. Attachment stresses are seen to reach peak values at locations where fretting cracks have been observed. Fretting stresses at the attachment region are seen to vary significantly as a function of crystal orientation. Attempts to adapt techniques used for estimating fatigue life in the airfoil region, for life calculations in the attachment region, are presented. An effective model for predicting crystallographic crack initiation under mixed mode loading is required for life prediction under fretting action.
Kim, Minjae; Brady, Joanne E; Li, Guohua
2015-12-01
Acute kidney injury (AKI), acute respiratory failure, and sepsis are distinct but related pathophysiologic processes. We hypothesized that these 3 processes may interact to synergistically increase the risk of short-term perioperative mortality in patients undergoing high-risk intraabdominal general surgery procedures. We performed a retrospective, observational cohort study of data (2005-2011) from the American College of Surgeons-National Surgical Quality Improvement Program, a high-quality surgical outcomes data set. High-risk procedures were those with a risk of AKI, acute respiratory failure, or sepsis greater than the average risk in all intraabdominal general surgery procedures. The effects of AKI, acute respiratory failure, and sepsis on 30-day mortality were assessed using a Cox proportional hazards model. Additive interactions were assessed with the relative excess risk due to interaction. Of 217,994 patients, AKI, acute respiratory failure, and sepsis developed in 1.3%, 3.7%, and 6.8%, respectively. The 30-day mortality risk with sepsis, acute respiratory failure, and AKI were 11.4%, 24.1%, and 25.1%, respectively, compared with 0.85% without these complications. The adjusted hazard ratios and 95% confidence intervals for a single complication (versus no complication) on mortality were 7.24 (6.46-8.11), 10.8 (8.56-13.6), and 14.2 (12.8-15.7) for sepsis, AKI, and acute respiratory failure, respectively. For 2 complications, the adjusted hazard ratios were 30.8 (28.0-33.9), 42.6 (34.3-52.9), and 65.2 (53.9-78.8) for acute respiratory failure/sepsis, AKI/sepsis, and acute respiratory failure/AKI, respectively. Finally, the adjusted hazard ratio for all 3 complications was 105 (92.8-118). Positive additive interactions, indicating synergism, were found for each combination of 2 complications. The relative excess risk due to interaction for all 3 complications was not statistically significant. In high-risk general surgery patients, the development of AKI, acute respiratory failure, or sepsis is independently associated with an increase in 30-day mortality. In addition, the development of 2 complications shows significant positive additive interactions to further increase the risk of mortality. Our findings suggest that interactions between these 3 perioperative complications increase the risk of mortality more than would be expected by the independent effects of each complication alone.
NASA Technical Reports Server (NTRS)
Brichenough, A. G.
1975-01-01
The control system consists of the ac-dc conversion, voltage regulation, speed regulation through parasitic load control, and overload control. A no-single-failure configuration was developed to attain the required reliability for a 10-year design life of unattended operation. The design principles, complete schematics, and performance are reported. Testing was performed on an alternator simulator pending construction of the actual Mini-Brayton alternator.
Charge collection and SEU mechanisms
NASA Astrophysics Data System (ADS)
Musseau, O.
1994-01-01
In the interaction of cosmic ions with microelectronic devices a dense electron-hole plasma is created along the ion track. Carriers are separated and transported by the electric field and under the action of the concentration gradient. The subsequent collection of these carriers induces a transient current at some electrical node of the device. This "ionocurrent" (single ion induced current) acts as any electrical perturbation in the device, propagating in the circuit and inducing failures. In bistable systems (registers, memories) the stored data can be upset. In clocked devices (microprocessors) the parasitic perturbation may propagate through the device to the outputs. This type of failure only effects the information, and do not degrade the functionally of the device. The purpose of this paper is to review the mechanisms of single event upset in microelectronic devices. Experimental and theoretical results are presented, and actual questions and problems are discussed. A brief introduction recalls the creation of the dense plasma of electron-hole pairs. The basic processes for charge collection in a simple np junction (drift and diffusion) are presented. The funneling-field effect is discussed and experimental results are compared to numerical simulations and semi-empirical models. Charge collection in actual microelectronic structures is then presented. Due to the parasitic elements, coupling effects are observed. Geometrical effects, in densely packed structures, results in multiple errors. Electronic couplings are due to the carriers in excess, acting as minority carriers, that trigger parasitic bipolar transistors. Single event upset of memory cells is discussed, based on numerical and experimental data. The main parameters for device characterization are presented. From the physical interpretation of charge collection mechanisms, the intrinsic sensitivity of various microelectronic technologies is determined and compared to experimental data. Scaling laws and future trends are finally discussed.
Bacon, David J.; Tang, Doug; Salas, Carola; Roncal, Norma; Lucas, Carmen; Gerena, Lucia; Tapia, Lorena; Llanos-Cuentas, A. Alejandro; Garcia, Coralith; Solari, Lelv; Kyle, Dennis; Magill, Alan J.
2009-01-01
Background Sulfadoxine-pyrimethamine was a common first line drug therapy to treat uncomplicated falciparum malaria, but increasing therapeutic failures associated with the development of significant levels of resistance worldwide has prompted change to alternative treatment regimes in many national malaria control programs. Methodology and Finding We conducted an in vivo therapeutic efficacy trial of sulfadoxine-pyrimethamine at two locations in the Peruvian Amazon enrolling 99 patients of which, 86 patients completed the protocol specified 28 day follow up. Our objective was to correlate the presence of polymorphisms in P. falciparum dihydrofolate reductase and dihydropteroate synthase to in vitro parasite susceptibility to sulfadoxine and pyrimethamine and to in vivo treatment outcomes. Inhibitory concentration 50 values of isolates increased with numbers of mutations (single [108N], sextuplet [BR/51I/108N/164L and 437G/581G]) and septuplet (BR/51I/108N/164L and 437G/540E/581G) with geometric means of 76 nM (35–166 nM), 582 nM (49-6890- nM) and 4909 (3575–6741 nM) nM for sulfadoxine and 33 nM (22–51 nM), 81 nM (19–345 nM), and 215 nM (176–262 nM) for pyrimethamine. A single mutation present in the isolate obtained at the time of enrollment from either dihydrofolate reductase (164L) or dihydropteroate synthase (540E) predicted treatment failure as well as any other single gene alone or in combination. Patients with the dihydrofolate reductase 164L mutation were 3.6 times as likely to be treatment failures [failures 85.4% (164L) vs 23.7% (I164); relative risk = 3.61; 95% CI: 2.14 – 6.64] while patients with the dihydropteroate synthase 540E were 2.6 times as likely to fail treatment (96.7% (540E) vs 37.5% (K540); relative risk = 2.58; 95% CI: 1.88 – 3.73). Patients with both dihydrofolate reductase 164L and dihydropteroate synthase 540E mutations were 4.1 times as likely to be treatment failures [96.7% vs 23.7%; RR = 4.08; 95% CI: 2.45 – 7.46] compared to patients having both wild forms (I164 and K540). Conclusions In this part of the Amazon basin, it may be possible to predict treatment failure with sulfadoxine-pyrimethamine equally well by determination of either of the single mutations dihydrofolate reductase 164L or dihydropteroate synthase 540E. Trial Registration ClinicalTrials.gov NCT00951106 NCT00951106 PMID:19707564
Interpreting Space-Mission LET Requirements for SEGR in Power MOSFETs
NASA Technical Reports Server (NTRS)
Lauenstein, J. M.; Ladbury, R. L.; Batchelor, D. A.; Goldsman, N.; Kim, H. S.; Phan, A. M.
2010-01-01
A Technology Computer Aided Design (TCAD) simulation-based method is developed to evaluate whether derating of high-energy heavy-ion accelerator test data bounds the risk for single-event gate rupture (SEGR) from much higher energy on-orbit ions for a mission linear energy transfer (LET) requirement. It is shown that a typical derating factor of 0.75 applied to a single-event effect (SEE) response curve defined by high-energy accelerator SEGR test data provides reasonable on-orbit hardness assurance, although in a high-voltage power MOSFET, it did not bound the risk of failure.
Studies of fiber-matrix adhesion on compression strength
NASA Technical Reports Server (NTRS)
Bascom, Willard D.; Nairn, John A.; Boll, D. J.
1991-01-01
A study was initiated on the effect of the matrix polymer and the fiber matrix bond strength of carbon fiber polymer matrix composites. The work includes tests with micro-composites, single ply composites, laminates, and multi-axial loaded cylinders. The results obtained thus far indicate that weak fiber-matrix adhesion dramatically reduces 0 degree compression strength. Evidence is also presented that the flaws in the carbon fiber that govern compression strength differ from those that determine fiber tensile strength. Examination of post-failure damage in the single ply tests indicates kink banding at the crack tip.
NASA Astrophysics Data System (ADS)
Harland, S. R.; Browning, J.; Healy, D.; Meredith, P. G.; Mitchell, T. M.
2017-12-01
Ultimate failure in brittle rocks is commonly accepted to occur as a coalescence of micro-crack damage into a single failure plane. The geometry and evolution with stress of the cracks (damage) within the medium will play a role in dictating the geometry of the ultimate failure plane. Currently, the majority of experimental studies investigating damage evolution and rock failure use conventional triaxial stress states (σ1 > σ2 = σ3). Results from these tests can easily be represented on a Mohr-Coulomb plot (σn - τ), conveniently allowing the user to determine the geometry of the resultant failure plane. In reality however, stress in the subsurface is generally truly triaxial (σ1 > σ2 > σ3) and in this case, the Mohr-Coulomb failure criterion is inadequate as it incorporates no dependence on the intermediate stress (σ2), which has been shown to play an important role in controlling failure. It has recently been shown that differential stress is the key driver in initiating crack growth, regardless of the mean stress. Polyaxial failure criteria that incorporate the effect of the intermediate stress do exist and include the Modified Lade, Modified Wiebols and Cook, and the Drucker-Prager criteria. However, unlike the Mohr-Coulomb failure criterion, these polyaxial criteria do not offer any prediction of, or insight into, the geometry of the resultant failure plane. An additional downfall of all of the common conventional and polyaxial failure criteria is that they fail to describe the geometry of the damage (i.e. pre-failure microcracking) envelope with progressive stress; it is commonly assumed that the damage envelope is parallel to the ultimate brittle failure envelope. Here we use previously published polyaxial failure data for the Shirahama sandstone and Westerley granite to illustrate that the commonly used Mohr-Coulomb and polyaxial failure criteria do not sufficiently describe or capture failure or damage envelopes under true triaxial stress states. We investigate if and how Mohr-Coulomb type constructions can provide geometrical solutions to truly-triaxial problems. We look to incorporate both the intermediate stress and the differential stress as the controlling parameters in failure and examine the geometry of damage envelopes using damage onset data.
Multimaterial lamination as a means of retarding penetration and spallation failures in plates
NASA Technical Reports Server (NTRS)
Dibattista, J. D.; Humes, D. H.
1972-01-01
Experimental data are presented which show that hypervelocity impact spallation and penetration failures of a single solid aluminum plate and of a solid aluminum plate spaced a distance behind a Whipple meteor bumper may be retarded by replacing the solid aluminum plate with a laminated plate. Four sets of experiments were conducted. The first set of experiments was conducted with projectile mass and velocity held constant and with polycarbonate cylinders impacted into single plates of different construction. The second set of experiments was done with single plates of various construction and aluminum spherical projectiles of similar mass but different velocities. These two experiments showed that a laminated plate of aluminum and polycarbonate or aluminum and methyl methacrylate could prevent spallation and penetration failures with a lower areal density than either an all-aluminum laminated plate or a solid aluminum plate. The aluminum laminated plate was in turn superior to the solid aluminum plate in resisting spallation and penetration failures. In addition, through an example of 6061-T6 aluminum and methyl methacrylate, it is shown that a laminated structure ballistically superior to its parent materials may be built. The last two sets of experiments were conducted using bumper-protected main walls of solid aluminum and of laminated aluminum and polycarbonate. Again, under hypervelocity impact conditions, the laminated main walls were superior to the solid aluminum main walls in retarding spallation and penetration failures.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang Changming; Li Xuan, E-mail: lixuanbysy@163.com; Song Shibing
2012-02-15
Purpose: This study was designed to introduce our novel technique of percutaneous single catheter placement into the hilar bile ducts strictures while fulfilling the purpose of bilateral biliary drainage and stenting. We investigated the efficacy and safety of the technique for the treatment of hilar nonanastomotic biliary strictures. Methods: Ten patients who were post-orthotopic liver transplantation between July 2000 and July 2010 were enrolled in this study. Percutaneous Y-configured single-catheter stenting for bilateral bile ducts combined with balloon dilation was designed as the main treatment approach. Technical success rate, clinical indicators, complications, and recurrent rate were analyzed. Results: Technical successmore » rate was 100%. Nine of the ten patients had biochemical normalization, cholangiographic improvement, and clinical symptoms relief. None of them experienced recurrence in a median follow-up of 26 months after completion of therapy and removal of all catheters. Complications were minor and limited to two patients. The one treatment failure underwent a second liver transplantation but died of multiple system organ failure. Conclusions: Percutaneous transhepatic Y-configured single-catheter stenting into the hilar bile ducts is technically feasible. The preliminary trial of this technique combined with traditional PTCD or choledochoscopy for the treatment of hilar biliary strictures after orthotopic liver transplantation appeared to be effective and safe. Yet, further investigation is needed.« less
An investigation of gear mesh failure prediction techniques. M.S. Thesis - Cleveland State Univ.
NASA Technical Reports Server (NTRS)
Zakrajsek, James J.
1989-01-01
A study was performed in which several gear failure prediction methods were investigated and applied to experimental data from a gear fatigue test apparatus. The primary objective was to provide a baseline understanding of the prediction methods and to evaluate their diagnostic capabilities. The methods investigated use the signal average in both the time and frequency domain to detect gear failure. Data from eleven gear fatigue tests were recorded at periodic time intervals as the gears were run from initiation to failure. Four major failure modes, consisting of heavy wear, tooth breakage, single pits, and distributed pitting were observed among the failed gears. Results show that the prediction methods were able to detect only those gear failures which involved heavy wear or distributed pitting. None of the methods could predict fatigue cracks, which resulted in tooth breakage, or single pits. It is suspected that the fatigue cracks were not detected because of limitations in data acquisition rather than in methodology. Additionally, the frequency response between the gear shaft and the transducer was found to significantly affect the vibration signal. The specific frequencies affected were filtered out of the signal average prior to application of the methods.
Lorbach, Olaf; Bachelier, Felix; Vees, Jochen; Kohn, Dieter; Pape, Dietrich
2008-08-01
Double-row repair is suggested to have superior biomechanical properties in rotator cuff reconstruction compared with single-row repair. However, double-row rotator cuff repair is frequently compared with simple suture repair and not with modified suture configurations. Single-row rotator cuff repairs with modified suture configurations have similar failure loads and gap formations as double-row reconstructions. Controlled laboratory study. We created 1 x 2-cm defects in 48 porcine infraspinatus tendons. Reconstructions were then performed with 4 single-row repairs and 2 double-row repairs. The single-row repairs included transosseous simple sutures; double-loaded corkscrew anchors in either a double mattress or modified Mason-Allen suture repair; and the Magnum Knotless Fixation Implant with an inclined mattress. Double-row repairs were either with Bio-Corkscrew FT using modified Mason-Allen stitches or a combination of Bio-Corkscrew FT and PushLock anchors using the SutureBridge Technique. During cyclic load (10 N to 60-200 N), gap formation was measured, and finally, ultimate load to failure and type of failure were recorded. Double-row double-corkscrew anchor fixation had the highest ultimate tensile strength (398 +/- 98 N) compared to simple sutures (105 +/- 21 N; P < .0001), single-row corkscrews using a modified Mason-Allen stitch (256 +/- 73 N; P = .003) or double mattress repair (290 +/- 56 N; P = .043), the Magnum Implant (163 +/- 13 N; P < .0001), and double-row repair with PushLock and Bio-Corkscrew FT anchors (163 +/- 59 N; P < .0001). Single-row double mattress repair was superior to transosseous sutures (P < .0001), the Magnum Implant (P = .009), and double-row repair with PushLock and Bio-Corkscrew FT anchors (P = .009). Lowest gap formation was found for double-row double-corkscrew repair (3.1 +/- 0.1 mm) compared to simple sutures (8.7 +/- 0.2 mm; P < .0001), the Magnum Implant (6.2 +/- 2.2 mm; P = .002), double-row repair with PushLock and Bio-Corkscrew FT anchors (5.9 +/- 0.9 mm; P = .008), and corkscrews with modified Mason-Allen sutures (6.4 +/- 1.3 mm; P = .001). Double-row double-corkscrew anchor rotator cuff repair offered the highest failure load and smallest gap formation and provided the most secure fixation of all tested configurations. Double-loaded suture anchors using modified suture configurations achieved superior results in failure load and gap formation compared to simple suture repair and showed similar loads and gap formation with double-row repair using PushLock and Bio-Corkscrew FT anchors. Single-row repair with modified suture configurations may lead to results comparable to several double-row fixations. If double-row repair is used, modified stitches might further minimize gap formation and increase failure load.
Colzato, Lorenza S; van der Wel, Pauline; Sellaro, Roberta; Hommel, Bernhard
2016-01-01
Recent studies show that a single bout of meditation can impact information processing. We were interested to see whether this impact extends to attentional focusing and the top-down control over irrelevant information. Healthy adults underwent brief single bouts of either focused attention meditation (FAM), which is assumed to increase top-down control, or open monitoring meditation (OMM), which is assumed to weaken top-down control, before performing a global-local task. While the size of the global-precedence effect (reflecting attentional focusing) was unaffected by type of meditation, the congruency effect (indicating the failure to suppress task-irrelevant information) was considerably larger after OMM than after FAM. Our findings suggest that engaging in particular kinds of meditation creates particular cognitive-control states that bias the individual processing style toward either goal-persistence or cognitive flexibility. Copyright © 2015 Elsevier Inc. All rights reserved.
Law, Yuk Ming; Ettedgui, Jose; Beerman, Lee; Maisel, Alan; Tofovic, Stevan
2006-08-15
The measurement of plasma B-type natriuretic peptide (BNP) has emerged as a useful biomarker of heart failure in patients with cardiomyopathy. The pathophysiology of heart failure in single ventricle (SV) circulation may be distinct from that of cardiomyopathies. A distinct pattern of BNP elevation in heart failure in the SV population was hypothesized: it is elevated in heart failure secondary to ventricular dysfunction but not in isolated cavopulmonary failure. BNP was measured prospectively in SV patients at catheterization (n = 22) and when assessing for heart failure (n = 11) (7 normal controls). Of 33 SV subjects (median age 62 months), 13 had aortopulmonary connections and 20 had cavopulmonary connections. Median and mean +/- SD BNP levels by shunt type were 184 and 754 +/- 1,086 pg/ml in the patients with aortopulmonary connections, 38 and 169 +/- 251 pg/ml in the patients with cavopulmonary connections, and 10 and 11 +/- 5 pg/ml in normal controls, respectively (p = 0.004). Median systemic ventricular end-diastolic pressure (8mm Hg, R = 0.45), mean pulmonary artery pressure (14.5 mm Hg, R = 0.62), and mean right atrial pressure (6.5 mm Hg, R = 0.54) were correlated with plasma BNP. SV subjects with symptomatic heart failure from dysfunctional systemic ventricles had median and mean +/- SD BNP levels of 378 and 714 +/- 912 pg/ml (n = 18) compared with patients with isolated failed Glenn or Fontan connections (19 and 23 +/- 16 pg/ml [n = 7, p = 0.001]) and those with no heart failure (22 and 22 +/- 12 pg/ml [n = 8, p = 0.001]). Excluding the group with cavopulmonary failure, the severity of heart failure from systemic ventricular dysfunction was associated with plasma BNP. In conclusion, plasma BNP is elevated in SV patients with systemic ventricular or left-sided cardiac failure. BNP is not elevated in patients missing a pulmonary ventricle with isolated cavopulmonary failure.
NASA Technical Reports Server (NTRS)
Kalinowski, Kevin F.; Tucker, George E.; Moralez, Ernesto, III
2006-01-01
Engineering development and qualification of a Research Flight Control System (RFCS) for the Rotorcraft Aircrew Systems Concepts Airborne Laboratory (RASCAL) JUH-60A has motivated the development of a pilot rating scale for evaluating failure transients in fly-by-wire flight control systems. The RASCAL RFCS includes a highly-reliable, dual-channel Servo Control Unit (SCU) to command and monitor the performance of the fly-by-wire actuators and protect against the effects of erroneous commands from the flexible, but single-thread Flight Control Computer. During the design phase of the RFCS, two piloted simulations were conducted on the Ames Research Center Vertical Motion Simulator (VMS) to help define the required performance characteristics of the safety monitoring algorithms in the SCU. Simulated failures, including hard-over and slow-over commands, were injected into the command path, and the aircraft response and safety monitor performance were evaluated. A subjective Failure/Recovery Rating (F/RR) scale was developed as a means of quantifying the effects of the injected failures on the aircraft state and the degree of pilot effort required to safely recover the aircraft. A brief evaluation of the rating scale was also conducted on the Army/NASA CH-47B variable stability helicopter to confirm that the rating scale was likely to be equally applicable to in-flight evaluations. Following the initial research flight qualification of the RFCS in 2002, a flight test effort was begun to validate the performance of the safety monitors and to validate their design for the safe conduct of research flight testing. Simulated failures were injected into the SCU, and the F/RR scale was applied to assess the results. The results validate the performance of the monitors, and indicate that the Failure/Recovery Rating scale is a very useful tool for evaluating failure transients in fly-by-wire flight control systems.
NASA Astrophysics Data System (ADS)
Sin, Yongkun; Ayvazian, Talin; Brodie, Miles; Lingley, Zachary
2018-03-01
High-power single-mode (SM) and multi-mode (MM) InGaAs-AlGaAs strained quantum well (QW) lasers are critical components for both terrestrial and space satellite communications systems. Since these lasers predominantly fail by catastrophic and sudden degradation due to catastrophic optical damage (COD), it is especially crucial for space satellite applications to investigate reliability, failure modes, precursor signatures of failure, and degradation mechanisms of these lasers. Our group reported a new failure mode in MM and SM InGaAs-AlGaAs strained QW lasers in 2009 and 2016, respectively. Our group also reported in 2017 that bulk failure due to catastrophic optical bulk damage (COBD) is the dominant failure mode of both SM and MM lasers that were subject to long-term life-tests. For the present study, we continued our physics of failure investigation by performing long-term life-tests followed by failure mode analysis (FMA) using nondestructive and destructive micro-analytical techniques. We performed long-term accelerated life-tests on state-of-the-art SM and MM InGaAs- AlGaAs strained QW lasers under ACC mode. Our life-tests have accumulated over 25,000 test hours for SM lasers and over 35,000 test hours for MM lasers. We first employed electron beam induced current (EBIC) technique to identify failure modes of degraded SM lasers by observing dark line defects. All the SM failures that we studied showed catastrophic and sudden degradation and all of these failures were bulk failures. Since degradation mechanisms responsible for COBD are still not well understood, we also employed other techniques including focused ion beam (FIB) and high-resolution TEM to further study dark line defects and dislocations in post-aged lasers. Keywor
Burkhart, Stephen S; Denard, Patrick J; Konicek, John; Hanypsiak, Bryan T
2014-02-01
Poor-quality tendon is one of the most difficult problems the surgeon must overcome in achieving secure fixation during rotator cuff repair. A load-sharing rip-stop construct (LSRS) has recently been proposed as a method for improving fixation strength, but the biomechanical properties of this construct have not yet been examined. To compare the strength of the LSRS construct to that of single-row fixation for rotator cuff repair. Controlled laboratory study. Rotator cuff tears were created in 6 cadaveric matched-pair specimens and repaired with a single row or an LSRS. In the LSRS repair, a 2-mm suture tape was placed as an inverted mattress stitch in the rotator cuff, and sutures from 2 anchors were placed as simple stitches that passed medial to the suture tape. The suture tape limbs were secured with knotless anchors laterally before sutures were tied from the medial anchors. Displacement was observed with video tracking after cyclic loading, and specimens were loaded to failure. The mean load to failure was 371 ± 102 N in single-row repairs compared with 616 ± 185 N in LSRS repairs (P = .031). There was no difference in displacement with cyclic loading between the groups (3.3 ± 0.8 mm vs. 3.5 ± 1.1 mm; P = .561). In the single-row group, 4 of 6 failures occurred at the suture-tendon interface. In the LSRS group, only 1 failure occurred at the suture-tendon interface. The ultimate failure load of the LSRS construct for rotator cuff repair was 1.7 times that of a single-row construct in a cadaveric model. The LSRS rotator cuff repair construct may be useful in the repair of difficult tears such as massive tears, medial tears, and tears with tendon loss.
Leventhal, Adam M.; Japuntich, Sandra J.; Piper, Megan E.; Jorenby, Douglas E.; Schlam, Tanya R.; Baker, Timothy B.
2012-01-01
Research exploring psychological dysfunction as a predictor of smoking cessation success may be limited by nonoptimal predictor variables (i.e., categorical psychodiagnostic measures vs. continuous personality-based manifestations of dysfunction) and imprecise outcomes (i.e., summative point prevalence abstinence vs. constituent cessation milestone measures). Accordingly, this study evaluated the unique and overlapping relations of broad-spectrum personality traits (positive emotionality, negative emotionality, and constraint) and past-year psychopathology (anxiety, mood, and substance use disorder) to point prevalence abstinence and three smoking cessation milestones: (1) initiating abstinence; (2) first lapse; and (3) transition from lapse to relapse. Participants were daily smokers (N=1365) enrolled in a smoking cessation treatment study. In single predictor regression models, each manifestation of internalizing dysfunction (lower positive emotionality, higher negative emotionality, and anxiety and mood disorder) predicted failure at one or more cessation milestone. In simultaneous predictor models, lower positive and higher negative emotionality significantly predicted failure to achieve milestones after controlling for psychopathology. Psychopathology did not predict any outcome when controlling for personality. Negative emotionality showed the most robust and consistent effects, significantly predicting failure to initiate abstinence, earlier lapse, and lower point prevalence abstinence rates. Substance use disorder and constraint did not predict cessation outcomes, and no single variable predicted lapse-to-relapse transition. These findings suggest that personality-related manifestations of internalizing dysfunction are more accurate markers of affective sources of relapse risk than mood and anxiety disorders. Further, individuals with high trait negative emotionality may require intensive intervention to promote the initiation and early maintenance of abstinence. PMID:22642858
Effectiveness of collateral vein embolization for salvage of immature native arteriovenous fistulas.
Ahmed, Osman; Patel, Mikin; Ginsburg, Michael; Jilani, Danial; Funaki, Brian
2014-12-01
To investigate the value of collateral vein embolization (CVE) as a salvage treatment for nonmaturing native arteriovenous fistulae (AVFs) in patients requiring hemodialysis. A total of 49 patients undergoing CVE (N = 65) for immature native AVFs at a single institution were reviewed. The study included 42 patients treated by 56 embolizations. Average fistula age at time of intervention was 18.2 weeks. Each patient underwent angiographic evaluation for fistula immaturity, with clinical success defined by initiation of single-session hemodialysis through the native fistula. Fistula maturity was achieved in 32 of 42 patients (76.2%). No major complications occurred. Average time from CVE to fistula maturity was 38.4 days. Angioplasty done with CVE was found in a statistically higher percentage of patients with fistula success versus failure (31.3% vs 8.3%; P = .039). Radiocephalic fistulae were seen in a higher percentage of fistula failures compared with successes, but the results were not statistically significant (83.3% vs 59.4%; P = .054). Thirty-four patients underwent CVE without angioplasty, which resulted in successful fistula maturation in 22 cases (64.7%). Radiocephalic fistulae were again seen in a higher percentage of fistula failures compared with successes, but the findings did not meet statistical significance (81.8% vs 54.5%; P = .052). Coil embolization of competing collateral vessels as a salvage treatment for nonfunctioning autologous AVFs is a viable treatment option in the majority of patients. Patients with radiocephalic fistulae may be at higher risk for primary fistula failure, but the present data are inconclusive. Copyright © 2014 SIR. Published by Elsevier Inc. All rights reserved.
ERIC Educational Resources Information Center
Rovito Gomez, Tina
2010-01-01
Autism spectrum disorders are characterized in terms of behavioral deficits in areas of social behavior and language development. A failure to attend to the faces of others is the single best discriminator between 1-year-old children later diagnosed with an autism spectrum disorder (ASD) and those with typical development. Attending to the face of…
Robert P. Long; Scott W. Bailey; Stephen B. Horsley; Thomas J. Hall; Bryan R. Swistock; David R. DeWalle
2015-01-01
Sugar maple (Acer saccharum Marsh.) decline disease, decreased growth, and regeneration failure have been related to a low supply of Ca and Mg. There is increased interest in augmenting cation availability via liming, but there is little information on the amounts of lime required and the longevity of the lime treatment. A single application of 22.4...
Heavy-Ion Testing of the Freescale Qorivva 32-bit Automotive-Grade MCU
NASA Technical Reports Server (NTRS)
Wilcox, Ted; Seidleck, Christina; Casey, Megan; LaBel, Ken
2016-01-01
We present single-event effects testing results from a commercially-available automotive microcontroller. We discuss the difficulties encountered testing with commercially-provided evaluation boards while attempting to classify the complex and varied failure modes of a modern 32-bit microcontroller. This work also describes some of the possible advantages to using off-the-shelf automotive-grade electronics for low-risk aerospace applications.
ERIC Educational Resources Information Center
Kanter, Jonathan W.; Landes, Sara J.; Busch, Andrew M.; Rusch, Laura C.; Brown, Keri R.; Baruch, David E.; Holman, Gareth I.
2006-01-01
The current study investigated a behavior-analytic treatment, functional analytic psychotherapy (FAP), for outpatient depression utilizing two single-subject A/A+B designs. The baseline condition was cognitive behavioral therapy. Results demonstrated treatment success in 1 client after the addition of FAP and treatment failure in the 2nd. This…
Esquivel, Amanda O.; Duncan, Douglas D.; Dobrasevic, Nikola; Marsh, Stephanie M.; Lemos, Stephen E.
2015-01-01
Background: Rotator cuff tendinopathy is a frequent cause of shoulder pain that can lead to decreased strength and range of motion. Failures after using the single-row technique of rotator cuff repair have led to the development of the double-row technique, which is said to allow for more anatomical restoration of the footprint. Purpose: To compare 5 different types of suture patterns while maintaining equality in number of anchors. The hypothesis was that the Mason-Allen–crossed cruciform transosseous-equivalent technique is superior to other suture configurations while maintaining equality in suture limbs and anchors. Study Design: Controlled laboratory study. Methods: A total of 25 fresh-frozen cadaveric shoulders were randomized into 5 suture configuration groups: single-row repair with simple stitch technique; single-row repair with modified Mason-Allen technique; double-row Mason-Allen technique; double-row cross-bridge technique; and double-row suture bridge technique. Load and displacement were recorded at 100 Hz until failure. Stiffness and bone mineral density were also measured. Results: There was no significant difference in peak load at failure, stiffness, maximum displacement at failure, or mean bone mineral density among the 5 suture configuration groups (P < .05). Conclusion: According to study results, when choosing a repair technique, other factors such as number of sutures in the repair should be considered to judge the strength of the repair. Clinical Relevance: Previous in vitro studies have shown the double-row rotator cuff repair to be superior to the single-row repair; however, clinical research does not necessarily support this. This study found no difference when comparing 5 different repair methods, supporting research that suggests the number of sutures and not the pattern can affect biomechanical properties. PMID:26665053
ERIC Educational Resources Information Center
What Works Clearinghouse, 2013
2013-01-01
The study reported in this paper examined the effects of “First Step to Success (First Step),” a school- and home-based program intended to improve outcomes for students with moderate to severe behavior problems who may be at risk for academic failure. The study took place in six locations across five states: San Jose, California; Tampa, Florida;…
Langenickel, Thomas H; Jordaan, Pierre; Petruck, Jesika; Kode, Kiran; Pal, Parasar; Vaidya, Soniya; Chandra, Priya; Rajman, Iris
2016-08-01
Sacubitril/valsartan (LCZ696) is a first-in-class angiotensin receptor neprilysin inhibitor (ARNI) indicated to reduce the risk of cardiovascular death and hospitalization for heart failure in patients with chronic heart failure (NYHA class II-IV) and reduced ejection fraction. This study was aimed to evaluate the effect of single oral therapeutic (400 mg) and supratherapeutic (1200 mg) doses of LCZ696 on cardiac repolarization. This randomized double-blind crossover study in healthy male subjects compared the effect of therapeutic and supratherapeutic doses of LCZ696 with placebo and moxifloxacin 400 mg (open-label treatment) as positive control. The primary assessment was mean baseline- and placebo-corrected QTcF (∆∆QTcF; Fridericia correction). Additional assessments included the ∆∆QTcB (Bazett's correction), PR interval, QRS duration, heart rate (HR), LCZ696 pharmacokinetics, pharmacokinetic/pharmacodynamic relationships, and safety. Of the 84 subjects enrolled, 81 completed the study. The maximum upper bound of the two-sided 90 % confidence interval for ∆∆QTcF for LCZ696 400 mg and 1200 mg were <10 ms, and assay sensitivity was confirmed with moxifloxacin. No relevant treatment-emergent changes were observed in any of the ECG-derived parameters with LCZ696 or placebo, and the incidence of adverse events was comparable among the treatment groups. Single therapeutic and supratherapeutic doses of LCZ696 did not affect cardiac repolarization as defined by the E14 ICH guidelines.
Medial Meniscal Root Avulsion: A Biomechanical Comparison of 4 Different Repair Constructs.
Mitchell, Richard; Pitts, Ryan; Kim, Young-Mo; Matava, Matthew J
2016-01-01
To evaluate the time-zero load-to-failure strength of 4 different constructs used to repair medial meniscal root avulsions. Sixty fresh-frozen cadaveric knees with a mean age of 74 years were used for this study. Each knee was dissected to isolate the attachment of the posterior root of the medial meniscus to the tibial plateau. An Instron machine (Instron, Norwood, MA) with a custom-designed clamp was used to avulse the intact posterior meniscal root in 12 control specimens. An additional 48 specimens were tested after transection of the native meniscal root to evaluate the pullout strength of 4 different repair constructs using No. 0 FiberWire suture (Arthrex, Naples, FL): a single suture (n = 12), a double suture (n = 12), a loop stitch (n = 12), and a locking loop stitch (n = 12). Analysis of variance was used to compare load to failure and stiffness of all 4 groups; pair-wise, between-group differences were also assessed. Repair failure occurred most commonly by suture pullout in 94% of the specimens in the repair groups. For the controls, failure occurred most commonly at the meniscus-clamp interface. Failure load was highest for the control group (mean, 359.5 ± 168 N), followed in descending order by the locking loop stitch (191.4 ± 45.1 N), loop stitch (119.6 ± 55.0 N), double suture (96.2 ± 51.4 N), and single suture (58.2 ± 29.6 N). The control group was significantly stronger than 3 of the experimental groups (single suture [95% CI, 3.8 to 11.3], double suture [95% CI, 2.1 to 6.4], and loop stitch [95% CI, 2.0 to 4.5]; P < .0001) but not the locking loop stitch (P = .003; 95% CI, 1.2 to 3.2). The locking loop stitch was significantly stronger than the single suture (P < .0001; 95% CI, 2.0 to 5.4) and double suture (P = .003; 95% CI, 1.2 to 2.9). The locking loop stitch was significantly stiffer than the single suture (P < .0001; 95% CI, 3.8 to 20.3), double suture (P < .0001; 95% CI, 2.0 to 9.8), and loop stitch (P = .03; 95% CI, 1.1 to 5.5) but not significantly different from the control group (P = .93; 95% CI, 0.3 to 1.9). Age and gender had no effect on pullout strength. The results of this study show that the locking loop stitch provided time-zero load-to-failure strength that most closely approximated the strength of the native meniscal root in addition to being significantly stronger and stiffer than 3 other commonly used repair methods. The true strength of the native meniscal root is unknown based on limitations with our testing methodology. The locking loop stitch exhibited the highest load to failure and stiffness of the 4 fixation methods tested, despite the fact that none of the fixation methods replicated the strength of the intact meniscal root. It is currently unknown what strength of fixation is required for healing of meniscal root repairs. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Jihoon; Moridis, George J.
We investigate coupled flow and geomechanics in gas production from extremely low permeability reservoirs such as tight and shale gas reservoirs, using dynamic porosity and permeability during numerical simulation. In particular, we take the intrinsic permeability as a step function of the status of material failure, and the permeability is updated every time step. We consider gas reservoirs with the vertical and horizontal primary fractures, employing the single and dynamic double porosity (dual continuum) models. We modify the multiple porosity constitutive relations for modeling the double porous continua for flow and geomechanics. The numerical results indicate that production of gasmore » causes redistribution of the effective stress fields, increasing the effective shear stress and resulting in plasticity. Shear failure occurs not only near the fracture tips but also away from the primary fractures, which indicates generation of secondary fractures. These secondary fractures increase the permeability significantly, and change the flow pattern, which in turn causes a change in distribution of geomechanical variables. From various numerical tests, we find that shear failure is enhanced by a large pressure drop at the production well, high Biot's coefficient, low frictional and dilation angles. Smaller spacing between the horizontal wells also contributes to faster secondary fracturing. When the dynamic double porosity model is used, we observe a faster evolution of the enhanced permeability areas than that obtained from the single porosity model, mainly due to a higher permeability of the fractures in the double porosity model. These complicated physics for stress sensitive reservoirs cannot properly be captured by the uncoupled or flow-only simulation, and thus tightly coupled flow and geomechanical models are highly recommended to accurately describe the reservoir behavior during gas production in tight and shale gas reservoirs and to smartly design production scenarios.« less
Kim, Jihoon; Moridis, George J.
2014-12-01
We investigate coupled flow and geomechanics in gas production from extremely low permeability reservoirs such as tight and shale gas reservoirs, using dynamic porosity and permeability during numerical simulation. In particular, we take the intrinsic permeability as a step function of the status of material failure, and the permeability is updated every time step. We consider gas reservoirs with the vertical and horizontal primary fractures, employing the single and dynamic double porosity (dual continuum) models. We modify the multiple porosity constitutive relations for modeling the double porous continua for flow and geomechanics. The numerical results indicate that production of gasmore » causes redistribution of the effective stress fields, increasing the effective shear stress and resulting in plasticity. Shear failure occurs not only near the fracture tips but also away from the primary fractures, which indicates generation of secondary fractures. These secondary fractures increase the permeability significantly, and change the flow pattern, which in turn causes a change in distribution of geomechanical variables. From various numerical tests, we find that shear failure is enhanced by a large pressure drop at the production well, high Biot's coefficient, low frictional and dilation angles. Smaller spacing between the horizontal wells also contributes to faster secondary fracturing. When the dynamic double porosity model is used, we observe a faster evolution of the enhanced permeability areas than that obtained from the single porosity model, mainly due to a higher permeability of the fractures in the double porosity model. These complicated physics for stress sensitive reservoirs cannot properly be captured by the uncoupled or flow-only simulation, and thus tightly coupled flow and geomechanical models are highly recommended to accurately describe the reservoir behavior during gas production in tight and shale gas reservoirs and to smartly design production scenarios.« less
Landry, Gregory J; McClary, Ashley; Liem, Timothy K; Mitchell, Erica L; Azarbal, Amir F; Moneta, Gregory L
2013-05-01
Finger amputations are typically performed as distal as possible to preserve maximum finger length. Failure of primary amputation leads to additional procedures, which could potentially be avoided if a more proximal amputation was initially performed. The effect of single versus multiple procedures on morbidity and mortality is not known. We evaluated factors that predicted primary healing and the effects of secondary procedures on survival. Patients undergoing finger amputations from 1995 to 2011 were evaluated for survival with uni- and multivariate analysis of demographic data and preoperative vascular laboratory studies to assess factors influencing primary healing. Seventy-six patients underwent 175 finger amputations (range 1 to 6 fingers per patient). Forty-one percent had diabetes, 33% had nonatherosclerotic digital artery disease, and 29% were on dialysis. Sex distribution was equal. Primary healing occurred in 78.9%, with the remainder requiring revisions. By logistic regression analysis, nonatherosclerotic digital artery disease was associated with failure of primary healing (odds ratio = 7.5; 95% confidence interval, 1.03 to 54; P = .047). Digital photoplethysmography did not predict primary healing. The overall healing of primary and secondary finger amputations was 96.0%. The mean survival after the initial finger amputation was 34.3 months and did not differ between patients undergoing single (35.6 months) versus multiple procedures (33.6 months). Dialysis dependence was associated with decreased survival (hazard ratio = 2.9; 95% confidence interval, 1.13 to 7.25; P = .026). Failure of primary healing is associated with the presence of nonatherosclerotic digital artery disease and is not predicted by digital photoplethysmographic studies. Dialysis dependence is associated with decreased survival in patients with finger amputations, but failure of primary healing does not adversely affect survival. A strategy of aggressive preservation of finger length is appropriate for most patients. Copyright © 2013. Published by Elsevier Inc.
Yousif, Matthew John; Bicos, James
2017-12-01
The glenohumeral joint is the most commonly dislocated joint in the body. Failure rates of capsulolabral repair have been reported to be approximately 8%. Recent focus has been on restoration of the capsulolabral complex by a double-row capsulolabral repair technique in an effort to decrease redislocation rates after arthroscopic capsulolabral repair. To present a review of the biomechanical literature comparing single- versus double-row capsulolabral repairs and discuss the previous case series of double-row fixation. Narrative review. A simple review of the literature was performed by PubMed search. Only biomechanical studies comparing single- versus double-row capsulolabral repair were included for review. Only those case series and descriptive techniques with clinical results for double-row repair were included in the discussion. Biomechanical comparisons evaluating the native footprint of the labrum demonstrated significantly superior restoration of the footprint through double-row capsulolabral repair compared with single-row repair. Biomechanical comparisons of contact pressure at the repair interface, fracture displacement in bony Bankart lesion, load to failure, and decreased external rotation (suggestive of increased load to failure) were also significantly in favor of double- versus single-row repair. Recent descriptive techniques and case series of double-row fixation have demonstrated good clinical outcomes; however, no comparative clinical studies between single- and double-row repair have assessed functional outcomes. The superiority of double-row capsulolabral repair versus single-row repair remains uncertain because comparative studies assessing clinical outcomes have yet to be performed.
Triaxial testing of Lopez Fault gouge at 150 MPa mean effective stress
Scott, D.R.; Lockner, D.A.; Byerlee, J.D.; Sammis, C.G.
1994-01-01
Triaxial compression experiments were performed on samples of natural granular fault gouge from the Lopez Fault in Southern California. This material consists primarily of quartz and has a self-similar grain size distribution thought to result from natural cataclasis. The experiments were performed at a constant mean effective stress of 150 MPa, to expose the volumetric strains associated with shear failure. The failure strength is parameterized by the coefficient of internal friction ??, based on the Mohr-Coulomb failure criterion. Samples of remoulded Lopez gouge have internal friction ??=0.6??0.02. In experiments where the ends of the sample are constrained to remain axially aligned, suppressing strain localisation, the sample compacts before failure and dilates persistently after failure. In experiments where one end of the sample is free to move laterally, the strain localises to a single oblique fault at around the point of failure; some dilation occurs but does not persist. A comparison of these experiments suggests that dilation is confined to the region of shear localisation in a sample. Overconsolidated samples have slightly larger failure strengths than normally consolidated samples, and smaller axial strains are required to cause failure. A large amount of dilation occurs after failure in heavily overconsolidated samples, suggesting that dilation is occurring throughout the sample. Undisturbed samples of Lopez gouge, cored from the outcrop, have internal friction in the range ??=0.4-0.6; the upper end of this range corresponds to the value established for remoulded Lopez gouge. Some kind of natural heterogeneity within the undisturbed samples is probably responsible for their low, variable strength. In samples of simulated gouge, with a more uniform grain size, active cataclasis during axial loading leads to large amounts of compaction. Larger axial strains are required to cause failure in simulated gouge, but the failure strength is similar to that of natural Lopez gouge. Use of the Mohr-Coulomb failure criterion to interpret the results from this study, and other recent studies on intact rock and granular gouge, leads to values of ?? that depend on the loading configuration and the intact or granular state of the sample. Conceptual models are advanced to account for these descrepancies. The consequences for strain-weakening of natural faults are also discussed. ?? 1994 Birkha??user Verlag.
Zhang, Jie-Min; Liu, Xiao-Cheng; Liu, Zhi-Gang; Zhao, Long; Yang, Li; Liu, Tian-Wen; He, Guo-Wei
2015-11-24
Previously designed intra-thoracic paraaortic counterpulsation device has limited stroke volume and may depress the lung to cause complications. The purpose of this study was to evaluate the hemodynamic effects of an extra-thoracic paraaortic counterpulsation device (ETPACD) in comparison to intraaortic balloon pump (IABP) in an animal model with acute heart failure. The acute heart failure model was successfully induced by snaring branch of anterior descending coronary artery in sheep (weighting, 38-50 kg, n = 8). The ETPACD is a single port, 65-ml stroke volume blood chamber designed to be connected to descending aorta through a valveless graft and placed extra-thorax. In comparison, a standard clinical 40-ml IABP was placed in the descending aorta. The hemodynamic indices of both devices were recorded during counterpulsation assistance. Two of the sheep were allowed to survive for 1 week to examine the prolonged effect. Both ETPACD and IABP increased cardiac output with higher effect of ETPACD (13.52 % vs. 8.19 % in IABP, P < 0.05) and on mean diastolic aortic pressure (26.73 % vs. 12.58 % in IABP, P < 0.01). Both ETPACD and IABP also produced a greater reduction in left ventricular end-diastolic pressure (26.77 % vs. 23.08 %, P > 0.05). The ETPACD increased left carotid artery flow more significantly the IABP (18.00 % vs. 9.19 % , P < 0.05). In two of the sheep allowed to survive for 1 week, the device worked well with no complications and there was no thrombus formation in the chamber of ETPACD. This study demonstrated that both ETPACD and IABP provided benefit of circulatory support in acute heart failure with better effect on hemodynamic parameters provided by ETPACD. Therefore, ETPACD with theoretical larger stroke volume may become a promising counterpulsation device for treatment of heart failure.
Chong, Alexander Cm; Prohaska, Daniel J; Bye, Brian P
2017-05-01
With arthroscopic techniques being used, the importance of knot tying has been examined. Previous literature has examined the use of reversing half-hitches on alternating posts (RHAPs) on knot security. Separately, there has been research regarding different suture materials commonly used in the operating room. The specific aim of this study was to validate the effect of different stacked half-hitch configuration and different braided suture materials on arthroscopic knot integrity. Three different suture materials tied with five different RHAPs in arthroscopic knots were compared. A single load-to-failure test was performed and the mean ultimate clinical failure load was obtained. Significant knot holding strength improvement was found when one half-hitch was reversed as compared to baseline knot. When two of the half-hitches were reversed, there was a greater improvement with all knots having a mean ultimate clinical failure load greater than 150 newtons (N). Comparison of the suture materials demonstrated a higher mean ultimate clinical failure load when Force Fiber ® was used and at least one half-hitch was reversed. Knots tied with either Force Fiber ® or Orthocord ® showed 0% chance of knot slippage while knots tied with FiberWire ® or braided fishing line had about 10 and 30% knot slippage chances, respectively. A significant effect was observed in regards to both stacked half-hitch configuration and suture materials used on knot loop and knot security. Caution should be used with tying three RHAPs in arthroscopic surgery, particularly with a standard knot pusher and arthroscopic cannulas. The findings of this study indicated the importance of three RHAPs in performing arthroscopic knot tying and provided evidence regarding discrepancies of maximum clinical failure loads observed between orthopaedic surgeons, thereby leading to better surgical outcomes in the future.
[Pain, flare-ups and failures in root canal therapy].
Moorer, W R
1989-10-01
In this overview the incidences and causes of pain, flare-ups and failures that occur after root canal therapy are discussed. Infection is considered the most important single, underlying determinant of the many factors that may cause pain and failures. Therefore, strict adherence to recognized therapeutic principles of shaping, disinfection and filling, in addition to proper aftercare, is of importance to diminish postoperative sequelae.
Cascading failures in ac electricity grids.
Rohden, Martin; Jung, Daniel; Tamrakar, Samyak; Kettemann, Stefan
2016-09-01
Sudden failure of a single transmission element in a power grid can induce a domino effect of cascading failures, which can lead to the isolation of a large number of consumers or even to the failure of the entire grid. Here we present results of the simulation of cascading failures in power grids, using an alternating current (AC) model. We first apply this model to a regular square grid topology. For a random placement of consumers and generators on the grid, the probability to find more than a certain number of unsupplied consumers decays as a power law and obeys a scaling law with respect to system size. Varying the transmitted power threshold above which a transmission line fails does not seem to change the power-law exponent q≈1.6. Furthermore, we study the influence of the placement of generators and consumers on the number of affected consumers and demonstrate that large clusters of generators and consumers are especially vulnerable to cascading failures. As a real-world topology, we consider the German high-voltage transmission grid. Applying the dynamic AC model and considering a random placement of consumers, we find that the probability to disconnect more than a certain number of consumers depends strongly on the threshold. For large thresholds the decay is clearly exponential, while for small ones the decay is slow, indicating a power-law decay.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sahgal, Arjun, E-mail: arjun.sahgal@sunnybrook.ca; Aoyama, Hidefumi; Kocher, Martin
Purpose: To perform an individual patient data (IPD) meta-analysis of randomized controlled trials evaluating stereotactic radiosurgery (SRS) with or without whole-brain radiation therapy (WBRT) for patients presenting with 1 to 4 brain metastases. Method and Materials: Three trials were identified through a literature search, and IPD were obtained. Outcomes of interest were survival, local failure, and distant brain failure. The treatment effect was estimated after adjustments for age, recursive partitioning analysis (RPA) score, number of brain metastases, and treatment arm. Results: A total of 364 of the pooled 389 patients met eligibility criteria, of whom 51% were treated with SRSmore » alone and 49% were treated with SRS plus WBRT. For survival, age was a significant effect modifier (P=.04) favoring SRS alone in patients ≤50 years of age, and no significant differences were observed in older patients. Hazard ratios (HRs) for patients 35, 40, 45, and 50 years of age were 0.46 (95% confidence interval [CI] = 0.24-0.90), 0.52 (95% CI = 0.29-0.92), 0.58 (95% CI = 0.35-0.95), and 0.64 (95% CI = 0.42-0.99), respectively. Patients with a single metastasis had significantly better survival than those who had 2 to 4 metastases. For distant brain failure, age was a significant effect modifier (P=.043), with similar rates in the 2 arms for patients ≤50 of age; otherwise, the risk was reduced with WBRT for patients >50 years of age. Patients with a single metastasis also had a significantly lower risk of distant brain failure than patients who had 2 to 4 metastases. Local control significantly favored additional WBRT in all age groups. Conclusions: For patients ≤50 years of age, SRS alone favored survival, in addition, the initial omission of WBRT did not impact distant brain relapse rates. SRS alone may be the preferred treatment for this age group.« less
NASA Astrophysics Data System (ADS)
Zhang, Jian; Liu, Wei; Gao, Weicheng
2018-02-01
This work is carried out to study the influence of double cutouts and stiffener reinforcements on the performance of I-section Carbon Fibre/Epoxy composites beam, including buckling, post-buckling behavior and the ultimate failure. The cantilever I-section beam with two diamond-shaped cutouts in the web and three longitudinal L-shaped stiffeners bonded to one side is subjected to a shear load at free end. Both numerical modelling and Experiment of I-section CFRP beam are performed. In numerical analysis, Tsai-Wu failure criterion is utilized to detect the first-ply-failure load in nonlinear analysis by predicting the load-deflection response. Good agreements are obtained from comparison between the numerical simulations and test results. For the double-hole beam web, the two cutouts show close surface deformation amplitude, which indicates that the stiffeners make the force transformation more effective. Comparing to the numerical result of corresponding beam with single cutout and stiffener reinforcement, the longitudinal stiffeners can not only play a significant role in improving the structural stability (increase about 30%), but also take effects to improve the deformation compatibility of structure. Local buckling happened within the sub-webs partioned by the stiffener and the buckling load is different but close. With post-buckling regime, the two areas show similar deformation characteristic, while the sub-web close to fixed end bears more shear load than the sub-web close to loading end with the increase of normal deformation of structure. The catastrophic failure load is approximate 75.6% higher comparing to buckling load. Results illustrate that the tensile fracture of the fiber is the immediate cause of the ultimate failure of the structure.
Schultheis, Stefan; Strub, Joerg R; Gerds, Thomas A; Guess, Petra C
2013-06-01
The authors analyzed the effect of fatigue on the survival rate and fracture load of monolithic and bi-layer CAD/CAM lithium-disilicate posterior three-unit fixed dental prostheses (FDPs) in comparison to the metal-ceramic gold standard. The authors divided 96 human premolars and molars into three equal groups. Lithium-disilicate ceramic (IPS-e.max-CAD) was milled with the CEREC-3-system in full-anatomic FDP dimensions (monolithic: M-LiCAD) or as framework (Bi-layer: BL-LiCAD) with subsequent hand-layer veneering. Metal-ceramic FDPs (MC) served as control. Single-load-to-failure tests were performed before and after mouth-motion fatigue. No fracture failures occurred during fatigue. Median fracture loads in [N], before and after fatigue were, respectively, as follows: M-LiCAD, 1,298/1,900; BL-LiCAD, 817/699; MC, 1,966/1,818. M-LiCAD and MC FPDs revealed comparable fracture loads and were both significantly higher than BL-LiCAD. M-LiCAD and BL-LiCAD both failed from core/veneer bulk fracture within the connector area. MC failures were limited to ceramic veneer fractures exposing the metal core. Fatigue had no significant effect on any group. Posterior monolithic CAD/CAM fabricated lithium-disilicate FPDs were shown to be fracture resistant with failure load results comparable to the metal-ceramic gold standard. Clinical investigations are needed to confirm these promising laboratory results. Monolithic CAD/CAM fabricated lithium-disilicate FDPs appeared to be a reliable treatment alternative for the posterior load-bearing area, whereas FDPs in bi-layer configuration were susceptible to low load fracture failure.
NASA Technical Reports Server (NTRS)
McCarty, John P.; Lyles, Garry M.
1997-01-01
Propulsion system quality is defined in this paper as having high reliability, that is, quality is a high probability of within-tolerance performance or operation. Since failures are out-of-tolerance performance, the probability of failures and their occurrence is the difference between high and low quality systems. Failures can be described at 3 levels: the system failure (which is the detectable end of a failure), the failure mode (which is the failure process), and the failure cause (which is the start). Failure causes can be evaluated & classified by type. The results of typing flight history failures shows that most failures are in unrecognized modes and result from human error or noise, i.e. failures are when engineers learn how things really work. Although the study based on US launch vehicles, a sampling of failures from other countries indicates the finding has broad application. The parameters of the design of a propulsion system are not single valued, but have dispersions associated with the manufacturing of parts. Many tests are needed to find failures, if the dispersions are large relative to tolerances, which could contribute to the large number of failures in unrecognized modes.
Reddy, Yeruva Madhu; Gunda, Sampath; Vallakati, Ajay; Kanmanthareddy, Arun; Pillarisetti, Jayasree; Atkins, Donita; Bommana, Sudharani; Emert, Martin P; Pimentel, Rhea; Dendi, Raghuveer; Berenbom, Loren D; Lakkireddy, Dhanunjaya
2015-09-15
Atrioventricular node (AVN) ablation is an effective treatment for symptomatic patients with atrial arrhythmias who are refractory to rhythm and rate control strategies where optimal ventricular rate control is desired. There are limited data on the predictors of failure of AVN ablation. Our objective was to identify the predictors of failure of AVN ablation. This is an observational single-center study of consecutive patients who underwent AVN ablation in a large academic center. Baseline characteristics, procedural variables, and outcomes of AVN ablation were collected. AVN "ablation failure" was defined as resumption of AVN conduction resulting in recurrence of either rapid ventricular response or suboptimal biventricular pacing. A total of 247 patients drug refractory AF who underwent AVN ablation at our center with a mean age of 71 ± 12 years with 46% being males were included. Ablation failure was seen in 11 (4.5%) patients. There were no statistical differences between patients with "ablation failure" versus "ablation success" in any of the baseline clinical variables. Patients with moderate-to-severe tricuspid regurgitation (TR) were much more likely to have ablation failure than those with ablation success (8 [73%] vs 65 [27%]; p = 0.003). All 11 patients with ablation failure had a successful redo procedure, 9 with right and 2 with the left sided approach. On multivariate analysis, presence of moderate-to-severe TR was found to be the only predictor of failure of AVN ablation (odds ratio 9.1, confidence interval 1.99 to 42.22, p = 0.004). In conclusion, moderate-to-severe TR is a strong and independent predictor of failure of AVN ablation. Copyright © 2015 Elsevier Inc. All rights reserved.
Mini-Ckpts: Surviving OS Failures in Persistent Memory
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fiala, David; Mueller, Frank; Ferreira, Kurt Brian
Concern is growing in the high-performance computing (HPC) community on the reliability of future extreme-scale systems. Current efforts have focused on application fault-tolerance rather than the operating system (OS), despite the fact that recent studies have suggested that failures in OS memory are more likely. The OS is critical to a system's correct and efficient operation of the node and processes it governs -- and in HPC also for any other nodes a parallelized application runs on and communicates with: Any single node failure generally forces all processes of this application to terminate due to tight communication in HPC. Therefore,more » the OS itself must be capable of tolerating failures. In this work, we introduce mini-ckpts, a framework which enables application survival despite the occurrence of a fatal OS failure or crash. Mini-ckpts achieves this tolerance by ensuring that the critical data describing a process is preserved in persistent memory prior to the failure. Following the failure, the OS is rejuvenated via a warm reboot and the application continues execution effectively making the failure and restart transparent. The mini-ckpts rejuvenation and recovery process is measured to take between three to six seconds and has a failure-free overhead of between 3-5% for a number of key HPC workloads. In contrast to current fault-tolerance methods, this work ensures that the operating and runtime system can continue in the presence of faults. This is a much finer-grained and dynamic method of fault-tolerance than the current, coarse-grained, application-centric methods. Handling faults at this level has the potential to greatly reduce overheads and enables mitigation of additional fault scenarios.« less
Sen, Barun Kumar; Pandit, Alak
2018-01-01
Guillain-Barré syndrome (GBS) has unpredictable clinical course with severe complication of respiratory failure. To identify clinical profiles and electrophysiological study particularly non-invasive Phrenic nerve conduction study in patients of early GBS to predict respiratory failure. 64 adult (age≥18yrs) patients of early GBS (onset ≤ 14 days) during the study period from January 2014 to October 2015 were evaluated by clinical profiles of age, gender, antecedent infection, time to peak disability, single breath counts, cranial nerve involvement, autonomic dysfunction and non-invasive Phrenic nerve conduction study. Patients with predisposition factors of polyneuropathy like diabetes mellitus, hypothyroidism, vitamin deficiency, renal failure were excluded. Among 64 patients abnormal phrenic nerve conduction study was seen in 65.62% cases (42/64) and 45.23% (19/42) of them developed respiratory failure. Phrenic nerve sum latency, amplitude, duration and area were abnormal in those who developed respiratory failure and they had sum of phrenic nerve latency >28 msec, sum of CMAP amplitude <300 μV, sum of CMAP duration >50 msec and sum of area < 4 mVmS. None with normal phrenic nerve study developed respiratory failure. It was found that age, gender, preceding infection, autonomic involvement and types of GB syndrome had no influence on development of respiratory failure (p>0.05). Rapid disease progression to peak disability, more severe disease, shorter single breath counts and cranial nerve involvement were seen more often in patients with respiratory failure. Abnormal Phrenic nerve conduction study in the early Guillain-Barré syndrome might be of great value independently in predicting impending respiratory failure.
Sen, Barun Kumar; Pandit, Alak
2018-01-01
Background: Guillain-Barré syndrome (GBS) has unpredictable clinical course with severe complication of respiratory failure. Objective: To identify clinical profiles and electrophysiological study particularly non-invasive Phrenic nerve conduction study in patients of early GBS to predict respiratory failure. Methods: 64 adult (age≥18yrs) patients of early GBS (onset ≤ 14 days) during the study period from January 2014 to October 2015 were evaluated by clinical profiles of age, gender, antecedent infection, time to peak disability, single breath counts, cranial nerve involvement, autonomic dysfunction and non-invasive Phrenic nerve conduction study. Patients with predisposition factors of polyneuropathy like diabetes mellitus, hypothyroidism, vitamin deficiency, renal failure were excluded. Results: Among 64 patients abnormal phrenic nerve conduction study was seen in 65.62% cases (42/64) and 45.23% (19/42) of them developed respiratory failure. Phrenic nerve sum latency, amplitude, duration and area were abnormal in those who developed respiratory failure and they had sum of phrenic nerve latency >28 msec, sum of CMAP amplitude <300 μV, sum of CMAP duration >50 msec and sum of area < 4 mVmS. None with normal phrenic nerve study developed respiratory failure. It was found that age, gender, preceding infection, autonomic involvement and types of GB syndrome had no influence on development of respiratory failure (p>0.05). Rapid disease progression to peak disability, more severe disease, shorter single breath counts and cranial nerve involvement were seen more often in patients with respiratory failure. Conclusion: Abnormal Phrenic nerve conduction study in the early Guillain-Barré syndrome might be of great value independently in predicting impending respiratory failure. PMID:29720799
NASA Astrophysics Data System (ADS)
Sin, Yongkun; Lingley, Zachary; Brodie, Miles; Presser, Nathan; Moss, Steven C.
2017-02-01
High-power single-mode (SM) and multi-mode (MM) InGaAs-AlGaAs strained quantum well (QW) lasers are critical components for both telecommunications and space satellite communications systems. However, little has been reported on failure modes and degradation mechanisms of high-power SM and MM InGaAs-AlGaAs strained QW lasers although it is crucial to understand failure modes and underlying degradation mechanisms in developing these lasers that meet lifetime requirements for space satellite systems, where extremely high reliability of these lasers is required. Our present study addresses the aforementioned issues by performing long-term life-tests followed by failure mode analysis (FMA) and physics of failure investigation. We performed long-term accelerated life-tests on state-of-the-art SM and MM InGaAs-AlGaAs strained QW lasers under ACC (automatic current control) mode. Our life-tests have accumulated over 25,000 test hours for SM lasers and over 35,000 test hours for MM lasers. FMA was performed on failed SM lasers using electron beam induced current (EBIC). This technique allowed us to identify failure types by observing dark line defects. All the SM failures we studied showed catastrophic and sudden degradation and all of these failures were bulk failures. Our group previously reported that bulk failure or COBD (catastrophic optical bulk damage) is the dominant failure mode of MM InGaAs-AlGaAs strained QW lasers. Since degradation mechanisms responsible for COBD are still not well understood, we also employed other techniques including focused ion beam (FIB) processing and high-resolution TEM to further study dark line defects and dislocations in post-aged lasers. Our long-term life-test results and FMA results are reported.
Acute Respiratory Failure in Renal Transplant Recipients: A Single Intensive Care Unit Experience.
Ulas, Aydin; Kaplan, Serife; Zeyneloglu, Pinar; Torgay, Adnan; Pirat, Arash; Haberal, Mehmet
2015-11-01
Frequency of pulmonary complications after renal transplant has been reported to range from 3% to 17%. The objective of this study was to evaluate renal transplant recipients admitted to an intensive care unit to identify incidence and cause of acute respiratory failure in the postoperative period and compare clinical features and outcomes between those with and without acute respiratory failure. We retrospectively screened the data of 540 consecutive adult renal transplant recipients who received their grafts at a single transplant center and included those patients admitted to an intensive care unit during this period for this study. Acute respiratory failure was defined as severe dyspnea, respiratory distress, decreased oxygen saturation, hypoxemia or hypercapnia on room air, or requirement of noninvasive or invasive mechanical ventilation. Among the 540 adult renal transplant recipients, 55 (10.7%) were admitted to an intensive care unit, including 26 (47.3%) admitted for acute respiratory failure. Median time from transplant to intensive care unit admission was 10 months (range, 0-67 mo). The leading causes of acute respiratory failure were bacterial pneumonia (56%) and cardiogenic pulmonary edema (44%). Mean partial pressure of arterial oxygen to fractional inspired oxygen ratio was 174 ± 59, invasive mechanical ventilation was used in 13 patients (50%), and noninvasive mechanical ventilation was used in 8 patients (31%). The overall mortality was 16.4%. Acute respiratory failure was the reason for intensive care unit admission in almost half of our renal transplant recipients. Main causes of acute respiratory failure were bacterial pneumonia and cardiogenic pulmonary edema. Mortality of patients admitted for acute respiratory failure was similar to those without acute respiratory failure.
De Maria, Elia; Borghi, Ambra; Bonetti, Lorenzo; Fontana, Pier Luigi; Cappelli, Stefano
2017-02-16
Conductor externalization and insulation failure are frequent complications with the recalled St. Jude Medical Riata implantable cardioverter-defibrillator (ICD) leads. Conductor externalization is a "unique" failure mechanism: Cables externalize through the insulation ("inside-out" abrasion) and appear outside the lead body. Recently, single reports described a similar failure also for Biotronik leads. Moreover, some studies reported a high rate of electrical dysfunction (not only insulation failure) with Biotronik Linox leads and a reduced survival rate in comparison with the competitors. In this paper we describe the case of a patient with a Biotronik Kentrox ICD lead presenting with signs of insulation failure and conductor externalization at fluoroscopy. Due to the high risk of extraction we decided to implant a new lead, abandoning the damaged one; lead reimplant was uneventful. Subsequently, we review currently available literature about Biotronik Kentrox and Linox ICD lead failure and in particular externalized conductors. Some single-center studies and a non-prospective registry reported a survival rate between 88% and 91% at 5 years for Linox leads, significantly worse than that of other manufacturers. However, the preliminary results of two ongoing multicenter, prospective registries (GALAXY and CELESTIAL) showed 96% survival rate at 5 years after implant, well within industry standards. Ongoing data collection is needed to confirm longer-term performance of this family of ICD leads.
De Maria, Elia; Borghi, Ambra; Bonetti, Lorenzo; Fontana, Pier Luigi; Cappelli, Stefano
2017-01-01
Conductor externalization and insulation failure are frequent complications with the recalled St. Jude Medical Riata implantable cardioverter-defibrillator (ICD) leads. Conductor externalization is a “unique” failure mechanism: Cables externalize through the insulation (“inside-out” abrasion) and appear outside the lead body. Recently, single reports described a similar failure also for Biotronik leads. Moreover, some studies reported a high rate of electrical dysfunction (not only insulation failure) with Biotronik Linox leads and a reduced survival rate in comparison with the competitors. In this paper we describe the case of a patient with a Biotronik Kentrox ICD lead presenting with signs of insulation failure and conductor externalization at fluoroscopy. Due to the high risk of extraction we decided to implant a new lead, abandoning the damaged one; lead reimplant was uneventful. Subsequently, we review currently available literature about Biotronik Kentrox and Linox ICD lead failure and in particular externalized conductors. Some single-center studies and a non-prospective registry reported a survival rate between 88% and 91% at 5 years for Linox leads, significantly worse than that of other manufacturers. However, the preliminary results of two ongoing multicenter, prospective registries (GALAXY and CELESTIAL) showed 96% survival rate at 5 years after implant, well within industry standards. Ongoing data collection is needed to confirm longer-term performance of this family of ICD leads. PMID:28255544
Enigmatic Moisture Effects on Al2O3 Scale and TBC Adhesion
NASA Technical Reports Server (NTRS)
Smialek, James L.
2008-01-01
Alumina scale adhesion to high temperature alloys is known to be affected primarily by sulfur segregation and reactive element additions. However, adherent scales can become partially compromised by excessive strain energy and cyclic cracking. With time, exposure of such scales to moisture can lead to spontaneous interfacial decohesion, occurring while the samples are maintained at ambient conditions. Examples of this Moisture-Induced Delayed Spallation (MIDS) are presented for NiCrAl and single crystal superalloys, becoming more severe with sulfur level and cyclic exposure conditions. Similarly, delayed failure or Desk Top Spallation (DTS) results are reviewed for thermal barrier coatings (TBCs), culminating in the water drop failure test. Both phenomena are discussed in terms of moisture effects on bulk alumina and bulk aluminides. A mechanism is proposed based on hydrogen embrittlement and is supported by a cathodic hydrogen charging experiment. Hydroxylation of aluminum from the alloy interface appears to be the relevant basic reaction.
Enigmatic Moisture Effects on Al2O3 Scale and TBC Adhesion
NASA Technical Reports Server (NTRS)
Smialek, James L.
2008-01-01
Alumina scale adhesion to high temperature alloys is known to be affected primarily by sulfur segregation and reactive element additions. However adherent scales can become partially compromised by excessive strain energy and cyclic cracking. With time, exposure of such scales to moisture can lead to spontaneous interfacial decohesion, occurring while the samples are maintained at ambient conditions. Examples of this Moisture-Induced Delayed Spallation (MIDS) are presented for NiCrAl and single crystal superalloys, becoming more severe with sulfur level and cyclic exposure conditions. Similarly, delayed failure or Desk Top Spallation (DTS) results are reviewed for TBC s, culminating in the water drop failure test. Both phenomena are discussed in terms of moisture effects on bulk alumina and bulk aluminides. A mechanism is proposed based on hydrogen embrittlement and is supported by a cathodic hydrogen charging experiment. Hydroxylation of aluminum from the alloy interface appears to be the relevant basic reaction.
Predicting effects of structural stress in a genome-reduced model bacterial metabolism
NASA Astrophysics Data System (ADS)
Güell, Oriol; Sagués, Francesc; Serrano, M. Ángeles
2012-08-01
Mycoplasma pneumoniae is a human pathogen recently proposed as a genome-reduced model for bacterial systems biology. Here, we study the response of its metabolic network to different forms of structural stress, including removal of individual and pairs of reactions and knockout of genes and clusters of co-expressed genes. Our results reveal a network architecture as robust as that of other model bacteria regarding multiple failures, although less robust against individual reaction inactivation. Interestingly, metabolite motifs associated to reactions can predict the propagation of inactivation cascades and damage amplification effects arising in double knockouts. We also detect a significant correlation between gene essentiality and damages produced by single gene knockouts, and find that genes controlling high-damage reactions tend to be expressed independently of each other, a functional switch mechanism that, simultaneously, acts as a genetic firewall to protect metabolism. Prediction of failure propagation is crucial for metabolic engineering or disease treatment.
Managing Disease Risks from Trade: Strategic Behavior with Many Choices and Price Effects.
Chitchumnong, Piyayut; Horan, Richard D
2018-03-16
An individual's infectious disease risks, and hence the individual's incentives for risk mitigation, may be influenced by others' risk management choices. If so, then there will be strategic interactions among individuals, whereby each makes his or her own risk management decisions based, at least in part, on the expected decisions of others. Prior work has shown that multiple equilibria could arise in this setting, with one equilibrium being a coordination failure in which individuals make too few investments in protection. However, these results are largely based on simplified models involving a single management choice and fixed prices that may influence risk management incentives. Relaxing these assumptions, we find strategic interactions influence, and are influenced by, choices involving multiple management options and market price effects. In particular, we find these features can reduce or eliminate concerns about multiple equilibria and coordination failure. This has important policy implications relative to simpler models.
Brown, Philip J; Mannava, Sandeep; Seyler, Thorsten M; Plate, Johannes F; Van Sikes, Charles; Stitzel, Joel D; Lang, Jason E
2016-10-26
Femoral head core decompression is an efficacious joint-preserving procedure for treatment of early stage avascular necrosis. However, postoperative fractures have been described which may be related to the decompression technique used. Femoral head decompressions were performed on 12 matched human cadaveric femora comparing large 8mm single bore versus multiple 3mm small drilling techniques. Ultimate failure strength of the femora was tested using a servo-hydraulic material testing system. Ultimate load to failure was compared between the different decompression techniques using two paired ANCOVA linear regression models. Prior to biomechanical testing and after the intervention, volumetric bone mineral density was determined using quantitative computed tomography to account for variation between cadaveric samples and to assess the amount of bone disruption by the core decompression. Core decompression, using the small diameter bore and multiple drilling technique, withstood significantly greater load prior to failure compared with the single large bore technique after adjustment for bone mineral density (p< 0.05). The 8mm single bore technique removed a significantly larger volume of bone compared to the 3mm multiple drilling technique (p< 0.001). However, total fracture energy was similar between the two core decompression techniques. When considering core decompression for the treatment of early stage avascular necrosis, the multiple small bore technique removed less bone volume, thereby potentially leading to higher load to failure.
A dislocation-based crystal plasticity framework for dynamic ductile failure of single crystals
Nguyen, Thao; Luscher, D. J.; Wilkerson, J. W.
2017-08-02
We developed a framework for dislocation-based viscoplasticity and dynamic ductile failure to model high strain rate deformation and damage in single crystals. The rate-dependence of the crystal plasticity formulation is based on the physics of relativistic dislocation kinetics suited for extremely high strain rates. The damage evolution is based on the dynamics of void growth, which are governed by both micro-inertia as well as dislocation kinetics and dislocation substructure evolution. Furthermore, an averaging scheme is proposed in order to approximate the evolution of the dislocation substructure in both the macroscale as well as its spatial distribution at the microscale. Inmore » addition, a concept of a single equivalent dislocation density that effectively captures the collective influence of dislocation density on all active slip systems is proposed here. Together, these concepts and approximations enable the use of semi-analytic solutions for void growth dynamics developed in [J. Wilkerson and K. Ramesh. A dynamic void growth model governed by dislocation kinetics. J. Mech. Phys. Solids, 70:262–280, 2014.], which greatly reduce the computational overhead that would otherwise be required. The resulting homogenized framework has been implemented into a commercially available finite element package, and a validation study against a suite of direct numerical simulations was carried out.« less
Redwan, Bassam; Ziegeler, Stephan; Semik, Michael; Fichter, Joachim; Dickgreber, Nicolas; Vieth, Volker; Ernst, Erik Christian; Fischer, Stefan
Lung volume reduction surgery (LVRS) is an important treatment option for end-stage lung emphysema in carefully selected patients. Here, we first describe the application of low-flow venovenous extracorporeal CO2 removal (LFVV-ECCO2R) as bridge to LVRS in patients with end-stage lung emphysema experiencing severe hypercapnia caused by acute failure of the breathing pump. Between March and October 2015, n = 4 patients received single-site LFVV-ECCO2R as bridge to LVRS. Indication for extracorporeal lung support was severe hypercapnia with respiratory acidosis and acute breathing pump failure. Two patients required continuous mechanical ventilation over a temporary tracheostomy and were bed ridden. The other two patients were nearly immobile because of severe dyspnea at rest. Length of preoperative ECCO2R was 14 (1-42) days. All patients underwent unilateral LVRS. Anatomical resection of the right (n = 3) or left (n = 1) upper lobe was performed. Postoperatively, both patients with previous mechanical ventilatory support were successfully weaned. ECCO2R in patients with end-stage lung emphysema experiencing severe hypercapnia caused by acute breathing pump failure is a safe and effective bridging tool to LVRS. In such patients, radical surgery leads to a significant improvement of the performance status and furthermore facilitates respiratory weaning from mechanical ventilation.
Spatio-temporal propagation of cascading overload failures in spatially embedded networks
NASA Astrophysics Data System (ADS)
Zhao, Jichang; Li, Daqing; Sanhedrai, Hillel; Cohen, Reuven; Havlin, Shlomo
2016-01-01
Different from the direct contact in epidemics spread, overload failures propagate through hidden functional dependencies. Many studies focused on the critical conditions and catastrophic consequences of cascading failures. However, to understand the network vulnerability and mitigate the cascading overload failures, the knowledge of how the failures propagate in time and space is essential but still missing. Here we study the spatio-temporal propagation behaviour of cascading overload failures analytically and numerically on spatially embedded networks. The cascading overload failures are found to spread radially from the centre of the initial failure with an approximately constant velocity. The propagation velocity decreases with increasing tolerance, and can be well predicted by our theoretical framework with one single correction for all the tolerance values. This propagation velocity is found similar in various model networks and real network structures. Our findings may help to predict the dynamics of cascading overload failures in realistic systems.
Spatio-temporal propagation of cascading overload failures in spatially embedded networks
Zhao, Jichang; Li, Daqing; Sanhedrai, Hillel; Cohen, Reuven; Havlin, Shlomo
2016-01-01
Different from the direct contact in epidemics spread, overload failures propagate through hidden functional dependencies. Many studies focused on the critical conditions and catastrophic consequences of cascading failures. However, to understand the network vulnerability and mitigate the cascading overload failures, the knowledge of how the failures propagate in time and space is essential but still missing. Here we study the spatio-temporal propagation behaviour of cascading overload failures analytically and numerically on spatially embedded networks. The cascading overload failures are found to spread radially from the centre of the initial failure with an approximately constant velocity. The propagation velocity decreases with increasing tolerance, and can be well predicted by our theoretical framework with one single correction for all the tolerance values. This propagation velocity is found similar in various model networks and real network structures. Our findings may help to predict the dynamics of cascading overload failures in realistic systems. PMID:26754065
NASA Astrophysics Data System (ADS)
Park, Jong Ho; Ahn, Byung Tae
2003-01-01
A failure model for electromigration based on the "failure unit model" was presented for the prediction of lifetime in metal lines.The failure unit model, which consists of failure units in parallel and series, can predict both the median time to failure (MTTF) and the deviation in the time to failure (DTTF) in Al metal lines. The model can describe them only qualitatively. In our model, both the probability function of the failure unit in single grain segments and polygrain segments are considered instead of in polygrain segments alone. Based on our model, we calculated MTTF, DTTF, and activation energy for different median grain sizes, grain size distributions, linewidths, line lengths, current densities, and temperatures. Comparisons between our results and published experimental data showed good agreements and our model could explain the previously unexplained phenomena. Our advanced failure unit model might be further applied to other electromigration characteristics of metal lines.
Enhancing Induction Coil Reliability
NASA Astrophysics Data System (ADS)
Kreter, K.; Goldstein, R.; Yakey, C.; Nemkov, V.
2014-12-01
In induction hardening, thermal fatigue is one of the main copper failure modes of induction heat treating coils. There have been papers published that describe this failure mode and others that describe some good design practices. The variables previously identified as the sources of thermal fatigue include radiation from the part surface, frequency, current, concentrator losses, water pressure and coil wall thickness. However, there is very little quantitative data on the factors that influence thermal fatigue in induction coils is available in the public domain. By using finite element analysis software this study analyzes the effect of common design variables of inductor cooling, and quantifies the relative importance of these variables. A comprehensive case study for a single shot induction coil with Fluxtrol A concentrator applied is used for the analysis.
Reevaluating the two-representation model of numerical magnitude processing.
Jiang, Ting; Zhang, Wenfeng; Wen, Wen; Zhu, Haiting; Du, Han; Zhu, Xiangru; Gao, Xuefei; Zhang, Hongchuan; Dong, Qi; Chen, Chuansheng
2016-01-01
One debate in mathematical cognition centers on the single-representation model versus the two-representation model. Using an improved number Stroop paradigm (i.e., systematically manipulating physical size distance), in the present study we tested the predictions of the two models for number magnitude processing. The results supported the single-representation model and, more importantly, explained how a design problem (failure to manipulate physical size distance) and an analytical problem (failure to consider the interaction between congruity and task-irrelevant numerical distance) might have contributed to the evidence used to support the two-representation model. This study, therefore, can help settle the debate between the single-representation and two-representation models.
Tensile bond strength of filled and unfilled adhesives to dentin.
Braga, R R; Cesar, P F; Gonzaga, C C
2000-04-01
To determine the tensile bond strength of three filled and two unfilled adhesives applied to bovine dentin. Fragments of the labial dentin of bovine incisors were embedded in PVC cylinders with self-cure acrylic resin, and ground flat using 200 grit and 600 grit sandpaper. The following adhesive systems were tested (n=10): Prime & Bond NT, Prime & Bond NT dual cure, Prime & Bond 2.1, OptiBond Solo and Single Bond. A 3 mm-diameter bonding surface was delimited using a perforated adhesive tape. After etching with 37% phosphoric acid and adhesive application, a resin-based composite truncated cone (TPH, shade A3) was built. Tensile test was performed after 24 hrs storage in distilled water at 37 degrees C. Failure mode was accessed using a x10 magnification stereomicroscope. Weibull statistical analysis revealed significant differences in the characteristic strength between Single Bond and Prime & Bond NT dual cure, and between Single Bond and Prime & Bond 2.1. The Weibull parameter (m) was statistically similar among the five groups. Single Bond and Prime & Bond NT showed areas of dentin cohesive failure in most of the specimens. For OptiBond Solo, Prime & Bond NT dual cure and Prime & Bond 2.1 failure was predominantly adhesive.
Oral theophylline in chronic heart failure
Al-Damluji, S.; Johnston, A.; Spurrell, R. A. J.; Nathan, A. W.; Banim, S. O.; Camm, A. J.
1982-01-01
Theophylline choline 600 mg was given as a single oral dose to nine patients in chronic left ventricular failure due to myocardial dysfunction. Cardiac output, left ventricular filling pressure (LVFP) and right atrial pressure (RAP) were measured with a pulmonary artery thermodilution catheter for the following 3 hr. Continuous recordings of cardiac rhythm were made throughout the study. Mean cardiac index increased from 1·75 (±0·14 s.e. mean) to 2·04 (±0·11) 1/min/m2 (P<0·02), mean LVFP fell from 27 (±2·4) to 22 (±1·5) mmHg (P<0·01), mean RAP fell from 5 (±1·3) to 3 (±2·0) mmHg (P<0·05) and mean systemic arterial pressure rose from 80 (±3) to 86 (±3·5) mmHg (P<0·05). There were no significant changes in heart rate or systemic vascular resistance; thus the increase in cardiac output was probably due to a positive inotropic effect. Side effects were seen in two patients, both of whom proved to have toxic plasma theophylline concentrations. This study demonstrated a beneficial acute haemodynamic effect of oral theophylline in chronic cardiac failure. PMID:7111101
Repair Strength in Simulated Restorations of Methacrylate- or Silorane-Based Composite Resins.
Consani, Rafael Leonardo Xediek; Marinho, Tatiane; Bacchi, Atais; Caldas, Ricardo Armini; Feitosa, Victor Pinheiro; Pfeifer, Carmem Silvia
2016-01-01
The study verified the bond strength in simulated dental restorations of silorane- or methacrylate-based composites repaired with methacrylate-based composite. Methacrylate- (P60) or silorane-based (P90) composites were used associated with adhesive (Adper Single Bond 2). Twenty-four hemi-hourglass-shaped samples were repaired with each composite (n=12). Samples were divided according to groups: G1= P60 + Adper Single Bond 2+ P60; G2= P60 + Adper Single Bond 2 + P60 + thermocycling; G3= P90 + Adper Single Bond 2 + P60; and G4= P90 + Adper Single Bond 2 + P60 + thermocycling. G1 and G3 were submitted to tensile test 24 h after repair procedure, and G2 and G4 after submitted to 5,000 thermocycles at 5 and 55 ?#61616;C for 30 s in each bath. Tensile bond strength test was accomplished in an universal testing machine at crosshead speed of 0.5 mm/min. Data (MPa) were analyzed by two-way ANOVA and Tukey's test (5%). Sample failure pattern (adhesive, cohesive in resin or mixed) was evaluated by stereomicroscope at 30?#61655; and images were obtained in SEM. Bond strength values of methacrylate-based composite samples repaired with methacrylate-based composite (G1 and G2) were greater than for silorane-based samples (G3 and G4). Thermocycling decreased the bond strength values for both composites. All groups showed predominance of adhesive failures and no cohesive failure in composite resin was observed. In conclusion, higher bond strength values were observed in methacrylate-based resin samples and greater percentage of adhesive failures in silorane-based resin samples, both composites repaired with methacrylate-based resin.
Access to pain treatment as a human right
2010-01-01
Background Almost five decades ago, governments around the world adopted the 1961 Single Convention on Narcotic Drugs which, in addition to addressing the control of illicit narcotics, obligated countries to work towards universal access to the narcotic drugs necessary to alleviate pain and suffering. Yet, despite the existence of inexpensive and effective pain relief medicines, tens of millions of people around the world continue to suffer from moderate to severe pain each year without treatment. Discussion Significant barriers to effective pain treatment include: the failure of many governments to put in place functioning drug supply systems; the failure to enact policies on pain treatment and palliative care; poor training of healthcare workers; the existence of unnecessarily restrictive drug control regulations and practices; fear among healthcare workers of legal sanctions for legitimate medical practice; and the inflated cost of pain treatment. These barriers can be understood not only as a failure to provide essential medicines and relieve suffering but also as human rights abuses. Summary According to international human rights law, countries have to provide pain treatment medications as part of their core obligations under the right to health; failure to take reasonable steps to ensure that people who suffer pain have access to adequate pain treatment may result in the violation of the obligation to protect against cruel, inhuman and degrading treatment. PMID:20089155
Ma, C Benjamin; Comerford, Lyn; Wilson, Joseph; Puttlitz, Christian M
2006-02-01
Recent studies have shown that arthroscopic rotator cuff repairs can have higher rates of failure than do open repairs. Current methods of rotator cuff repair have been limited to single-row fixation of simple and horizontal stitches, which is very different from open repairs. The objective of this study was to compare the initial cyclic loading and load-to-failure properties of double-row fixation with those of three commonly used single-row techniques. Ten paired human supraspinatus tendons were split in half, yielding four tendons per cadaver. The bone mineral content at the greater tuberosity was assessed. Four stitch configurations (two-simple, massive cuff, arthroscopic Mason-Allen, and double-row fixation) were randomized and tested on each set of tendons. Specimens were cyclically loaded between 5 and 100 N at 0.25 Hz for fifty cycles and then loaded to failure under displacement control at 1 mm/sec. Conditioning elongation, peak-to-peak elongation, ultimate tensile load, and stiffness were measured with use of a three-dimensional tracking system and compared, and the failure type (suture or anchor pull-out) was recorded. No significant differences were found among the stitches with respect to conditioning elongation. The mean peak-to-peak elongation (and standard error of the mean) was significantly lower for the massive cuff (1.1 +/- 0.1 mm) and double-row stitches (1.1 +/- 0.1 mm) than for the arthroscopic Mason-Allen stitch (1.5 +/- 0.2 mm) (p < 0.05). The ultimate tensile load was significantly higher for double-row fixation (287 +/- 24 N) than for all of the single-row fixations (p < 0.05). Additionally, the massive cuff stitch (250 +/- 21 N) was found to have a significantly higher ultimate tensile load than the two-simple (191 +/- 18 N) and arthroscopic Mason-Allen (212 +/- 21 N) stitches (p < 0.05). No significant differences in stiffness were found among the stitches. Failure mechanisms were similar for all stitches. Rotator cuff repairs in the anterior half of the greater tuberosity had a significantly lower peak-to-peak elongation and higher ultimate tensile strength than did repairs on the posterior half. In this in vitro cadaver study, double-row fixation had a significantly higher ultimate tensile load than the three types of single-row fixation stitches. Of the single-row fixations, the massive cuff stitch had cyclic and load-to-failure characteristics similar to the double-row fixation. Anterior repairs of the supraspinatus tendon had significantly stronger biomechanical behavior than posterior repairs.
Laughlin, Gail A.
2009-01-01
There are more than 200 published scientific papers showing that estrogen has favorable effects on brain tissue and physiology in cell culture and animal models including nonhuman primates. The biological plausibility for a neuroprotective estrogen effect is overwhelming. However, most studies of endogenous estrogen and cognitive decline or dementia fail to show protection, and some suggest harm. Failure to find any consistent association might reflect the limitations of a single time of estrogen assay or poor assay sensitivity. More than half of the observational studies of hormone therapy suggest benefit. Nearly all long term clinical trials fail to show benefit and the longer trials tend to show harm. Failure to adequately adjust for self-selection of healthier and wealthier women and publication bias could account for some, or all, of the protective effect attributed to estrogen in observational studies. Overall, the evidence does not convincingly support the prescription of early or late postmenopausal estrogen therapy to preserve cognitive function or prevent dementia. PMID:19401958
System Certification Procedures and Criteria Manual for Deep Submergence Systems
1973-07-01
Certification Milestone Events. The applicant and SCA interplay and negotiations between milestones is stressed . Effective and frequent communication...a series of events beginning with a single failure, often relatively minor, which may place the DSq Personnel or equipments under additional stresses ...for the particular DSS. p. Support ship handling system components such as cranes , brakes, and cables when the DSS is handled with personnel aboard. q
Effects of Heavy Ion Exposure on Nanocrystal Nonvolatile Memory
NASA Technical Reports Server (NTRS)
Oldham, Timothy R.; Suhail, Mohammed; Kuhn, Peter; Prinz, Erwin; Kim, Hak; LaBel, Kenneth A.
2004-01-01
We have irradiated engineering samples of Freescale 4M nonvolatile memories with heavy ions. They use Silicon nanocrystals as the storage element, rather than the more common floating gate. The irradiations were performed using the Texas A&M University cyclotron Single Event Effects Test Facility. The chips were tested in the static mode, and in the dynamic read mode, dynamic write (program) mode, and dynamic erase mode. All the errors observed appeared to be due to single, isolated bits, even in the program and erase modes. These errors appeared to be related to the micro-dose mechanism. All the errors corresponded to the loss of electrons from a programmed cell. The underlying physical mechanisms will be discussed in more detail later. There were no errors, which could be attributed to malfunctions of the control circuits. At the highest LET used in the test (85 MeV/mg/sq cm), however, there appeared to be a failure due to gate rupture. Failure analysis is being conducted to confirm this conclusion. There was no unambiguous evidence of latchup under any test conditions. Generally, the results on the nanocrystal technology compare favorably with results on currently available commercial floating gate technology, indicating that the technology is promising for future space applications, both civilian and military.
Simulated fault injection - A methodology to evaluate fault tolerant microprocessor architectures
NASA Technical Reports Server (NTRS)
Choi, Gwan S.; Iyer, Ravishankar K.; Carreno, Victor A.
1990-01-01
A simulation-based fault-injection method for validating fault-tolerant microprocessor architectures is described. The approach uses mixed-mode simulation (electrical/logic analysis), and injects transient errors in run-time to assess the resulting fault impact. As an example, a fault-tolerant architecture which models the digital aspects of a dual-channel real-time jet-engine controller is used. The level of effectiveness of the dual configuration with respect to single and multiple transients is measured. The results indicate 100 percent coverage of single transients. Approximately 12 percent of the multiple transients affect both channels; none result in controller failure since two additional levels of redundancy exist.
NASA Astrophysics Data System (ADS)
Kerr-Anderson, Eric
Structural composite laminates were ballistically impacted while under in-plane compressive pre-stress. Residual properties, damage characterization, and energy absorption were compared to determine synergistic effects of in-plane compressive pre-stress and impact velocity. A fixture was developed to apply in-plane compressive loads up to 30 tons to structural composites during an impact event using a single-stage light-gas gun. Observed failure modes included typical conical delamination, the development of an impact initiated shear crack (IISC), and the shear failure of a pre-stressed composite due to impact. It was observed that the compressive failure threshold quadratically decreased in relation to the impact velocity up to velocities that caused partial penetration. For all laminates impacted at velocities causing partial or full penetration up to 350 ms-1, the failure threshold was consistent and used as an experimental normalization. Samples impacted below 65% of the failure threshold witnessed no significant change in damage morphology or residual properties when compared to typical conical delamination. Samples impacted above 65% of the failure threshold witnessed additional damage in the form of a shear crack extending perpendicular to the applied load from the point of impact. The presence of an IISC reduced the residual properties and even caused failure upon impact at extreme combinations. Four failure envelopes have been established as: transient failure, steady state failure, impact initiated shear crack, and conical damage. Boundaries and empirically based equations for residual compressive strength have been developed for each envelope with relation to two E-glass/vinyl ester laminate systems. Many aspects of pre-stressed impact have been individually examined, but there have been no comprehensive examinations of pre-stressed impact. This research has resulted in the exploration and characterization of compressively pre-stressed damage for impact velocities resulting in reflection, partial penetration, and penetration at pre-stress levels resulting in conical damage, shear cracking, and failure.
3D Thermal and Mechanical Analysis of a Single Event Burnout
NASA Astrophysics Data System (ADS)
Peretti, Gabriela; Demarco, Gustavo; Romero, Eduardo; Tais, Carlos
2015-08-01
This paper presents a study related to thermal and mechanical behavior of power DMOS transistors during a Single Event Burnout (SEB) process. We use a cylindrical heat generation region for emulating the thermal and mechanical phenomena related to the SEB. In this way, it is avoided the complexity of the mathematical treatment of the ion-device interaction. This work considers locating the heat generation region in positions that are more realistic than the ones used in previous work. For performing the study, we formulate and validate a new 3D model for the transistor that maintains the computational cost at reasonable level. The resulting mathematical models are solved by means of the Finite Element Method. The simulations results show that the failure dynamics is dominated by the mechanical stress in the metal layer. Additionally, the time to failure depends on the heat source position, for a given power and dimension of the generation region. The results suggest that 3D modeling should be considered for a detailed study of thermal and mechanical effects induced by SEBs.
NASA Astrophysics Data System (ADS)
Zhao, Yang; Dong, Shuhong; Yu, Peishi; Zhao, Junhua
2018-06-01
The loading direction-dependent shear behavior of single-layer chiral graphene sheets at different temperatures is studied by molecular dynamics (MD) simulations. Our results show that the shear properties (such as shear stress-strain curves, buckling strains, and failure strains) of chiral graphene sheets strongly depend on the loading direction due to the structural asymmetry. The maximum values of both the critical buckling shear strain and the failure strain under positive shear deformation can be around 1.4 times higher than those under negative shear deformation. For a given chiral graphene sheet, both its failure strain and failure stress decrease with increasing temperature. In particular, the amplitude to wavelength ratio of wrinkles for different chiral graphene sheets under shear deformation using present MD simulations agrees well with that from the existing theory. These findings provide physical insights into the origins of the loading direction-dependent shear behavior of chiral graphene sheets and their potential applications in nanodevices.
Red blood cell transfusion, hyperkalemia, and heart failure in advanced chronic kidney disease.
Gill, Karminder; Fink, Jeffrey C; Gilbertson, David T; Monda, Keri L; Muntner, Paul; Lafayette, Richard A; Petersen, Jeffrey; Chertow, Glenn M; Bradbury, Brian D
2015-06-01
In recent years, the use of red blood cell (RBC) transfusion for the treatment of chronic kidney disease (CKD)-related anemia has increased. We used the OptumInsight medical claims database to study the association between receiving a transfusion and hyperkalemia and heart failure events. Persons 18-64 years of age with diagnosed stage 4 or 5 CKD (not requiring dialysis) between 2006 and 2010 were followed until their first hospitalization or emergency room visit with a diagnosis of hyperkalemia or heart failure, termination of insurance coverage, or death. We used a case-only design and conditional logistic regression to estimate rate ratios (RR) and 95% confidence intervals (CIs) describing associations between RBC transfusion and the risks of hyperkalemia or heart failure. We used single (1:1) and variable (1:m) self-control matching intervals, with adjustment for time-varying confounders. Seven thousand eight hundred twenty-nine individuals met our inclusion criteria; two-thirds were age 50 years or older; 43% were women and 51% had diabetes. Rates of hyperkalemia and heart failure were 7.9/100 person-years (95%CI: 7.3, 8.5) and 16.3/100 person-years (95%CI: 15.5, 17.2), respectively. RBC transfusion was associated with an increased risk of both hyperkalemia (single interval matched RR = 12.0, 95%CI: 1.3, 109; multiple interval matched RR = 6.1, 95%CI: 2.5, 15.1) and heart failure (single interval matched RR = 1.7, 95%CI: 0.3, 9.2; multiple interval matched RR = 3.8, 95%CI: 1.4, 10.3). In patients with advanced CKD, RBC transfusion appears to be associated with an elevated risk of hyperkalemia and heart failure; further investigation into these risks is warranted. Copyright © 2015 John Wiley & Sons, Ltd.
Baldinger, Samuel H; Kumar, Saurabh; Barbhaiya, Chirag R; Mahida, Saagar; Epstein, Laurence M; Michaud, Gregory F; John, Roy; Tedrow, Usha B; Stevenson, William G
2015-12-01
Radiofrequency ablation (RFA) from the epicardial space for ventricular arrhythmias is limited or impossible in some cases. Reasons for epicardial ablation failure and the effect on outcome have not been systematically analyzed. We assessed reasons for epicardial RFA failure relative to the anatomic target area and the type of heart disease and assessed the effect of failed epicardial RFA on outcome after ablation procedures for ventricular arrhythmias in a large single-center cohort. Epicardial access was attempted during 309 ablation procedures in 277 patients and was achieved in 291 procedures (94%). Unlimited ablation in an identified target region could be performed in 181 cases (59%), limited ablation was possible in 22 cases (7%), and epicardial ablation was deemed not feasible in 88 cases (28%). Reasons for failed or limited ablation were unsuccessful epicardial access (6%), failure to identify an epicardial target (15%), proximity to a coronary artery (13%), proximity to the phrenic nerve (6%), and complications (<1%). Epicardial RFA was impeded in the majority of cases targeting the left ventricular summit region. Acute complications occurred in 9%. The risk for acute ablation failure was 8.3× higher (4.5-15.0; P<0.001) after no or limited epicardial RFA compared with unlimited RFA, and patients with unlimited epicardial RFA had better recurrence-free survival rates (P<0.001). Epicardial RFA for ventricular arrhythmias is often limited even when pericardial access is successful. Variability of success is dependent on the target area, and the presence of factors limiting ablation is associated with worse outcomes. © 2015 American Heart Association, Inc.
Senni, Michele; Paulus, Walter J.; Gavazzi, Antonello; Fraser, Alan G.; Díez, Javier; Solomon, Scott D.; Smiseth, Otto A.; Guazzi, Marco; Lam, Carolyn S. P.; Maggioni, Aldo P.; Tschöpe, Carsten; Metra, Marco; Hummel, Scott L.; Edelmann, Frank; Ambrosio, Giuseppe; Stewart Coats, Andrew J.; Filippatos, Gerasimos S.; Gheorghiade, Mihai; Anker, Stefan D.; Levy, Daniel; Pfeffer, Marc A.; Stough, Wendy Gattis; Pieske, Burkert M.
2014-01-01
The management of heart failure with reduced ejection fraction (HF-REF) has improved significantly over the last two decades. In contrast, little or no progress has been made in identifying evidence-based, effective treatments for heart failure with preserved ejection fraction (HF-PEF). Despite the high prevalence, mortality, and cost of HF-PEF, large phase III international clinical trials investigating interventions to improve outcomes in HF-PEF have yielded disappointing results. Therefore, treatment of HF-PEF remains largely empiric, and almost no acknowledged standards exist. There is no single explanation for the negative results of past HF-PEF trials. Potential contributors include an incomplete understanding of HF-PEF pathophysiology, the heterogeneity of the patient population, inadequate diagnostic criteria, recruitment of patients without true heart failure or at early stages of the syndrome, poor matching of therapeutic mechanisms and primary pathophysiological processes, suboptimal study designs, or inadequate statistical power. Many novel agents are in various stages of research and development for potential use in patients with HF-PEF. To maximize the likelihood of identifying effective therapeutics for HF-PEF, lessons learned from the past decade of research should be applied to the design, conduct, and interpretation of future trials. This paper represents a synthesis of a workshop held in Bergamo, Italy, and it examines new and emerging therapies in the context of specific, targeted HF-PEF phenotypes where positive clinical benefit may be detected in clinical trials. Specific considerations related to patient and endpoint selection for future clinical trials design are also discussed. PMID:25104786
NASA Technical Reports Server (NTRS)
Haakensen, Erik Edward
1998-01-01
The desire for low-cost reliable computing is increasing. Most current fault tolerant computing solutions are not very flexible, i.e., they cannot adapt to reliability requirements of newly emerging applications in business, commerce, and manufacturing. It is important that users have a flexible, reliable platform to support both critical and noncritical applications. Chameleon, under development at the Center for Reliable and High-Performance Computing at the University of Illinois, is a software framework. for supporting cost-effective adaptable networked fault tolerant service. This thesis details a simulation of fault injection, detection, and recovery in Chameleon. The simulation was written in C++ using the DEPEND simulation library. The results obtained from the simulation included the amount of overhead incurred by the fault detection and recovery mechanisms supported by Chameleon. In addition, information about fault scenarios from which Chameleon cannot recover was gained. The results of the simulation showed that both critical and noncritical applications can be executed in the Chameleon environment with a fairly small amount of overhead. No single point of failure from which Chameleon could not recover was found. Chameleon was also found to be capable of recovering from several multiple failure scenarios.
Cascading failures in interconnected networks with dynamical redistribution of loads
NASA Astrophysics Data System (ADS)
Zhao, Zhuang; Zhang, Peng; Yang, Hujiang
2015-09-01
Cascading failures of loads in isolated networks and coupled networks have been studied in the past few years. In most of the corresponding results, the topologies of the networks are destroyed. Here, we present an interconnected network model considering cascading failures based on the dynamic redistribution of flow in the networks. Compared with the results of single scale-free networks, we find that interconnected scale-free networks have higher vulnerability. Additionally, the network heterogeneity plays an important role in the robustness of interconnected networks under intentional attacks. Considering the effects of various coupling preferences, the results show that there are almost no differences. Finally, the application of our model to the Beijing interconnected traffic network, which consists of a subway network and a bus network, shows that the subway network suffers more damage under the attack. Moreover, the interconnected traffic network may be more exposed to damage after initial attacks on the bus network. These discussions are important for the design and optimization of interconnected networks.
[Lung abscess and necrotizing pneumonia: chest tube insertion or surgery?].
Pagès, P-B; Bernard, A
2012-04-01
Lung abscesses and necrotizing pneumonia are rare complications of community-acquired pneumonia since the advent of antibiotics. Their management leans first of all on the antibiotic treatment adapted on the informed germs. However, in 11 to 20% of the cases of lung abscesses, this treatment is insufficient, and drainage, either endoscopic or percutaneous, must be envisaged. In first intention, we shall go to less invasive techniques: endoscopic or percutaneous radio-controlled. In case of failure of these techniques, a percutaneous surgical drainage by minithoracotomy will be performed. In the necrotizing pneumonia, because of the joint obstruction of the bronchus and blood vessels corresponding to a lung segment, the systemic antibiotic treatment will be poor effective. In case of failure of this one we shall propose, a percutaneous surgical drainage, especially if the necrosis limits itself to a single lobe. The surgical treatment will be reserved: in the failures of the strategy of surgical drainage, in the necroses extending in several lobes. Copyright © 2012 Elsevier Masson SAS. All rights reserved.
Voltage stress effects on microcircuit accelerated life test failure rates
NASA Technical Reports Server (NTRS)
Johnson, G. M.
1976-01-01
The applicability of Arrhenius and Eyring reaction rate models for describing microcircuit aging characteristics as a function of junction temperature and applied voltage was evaluated. The results of a matrix of accelerated life tests with a single metal oxide semiconductor microcircuit operated at six different combinations of temperature and voltage were used to evaluate the models. A total of 450 devices from two different lots were tested at ambient temperatures between 200 C and 250 C and applied voltages between 5 Vdc and 15 Vdc. A statistical analysis of the surface related failure data resulted in bimodal failure distributions comprising two lognormal distributions; a 'freak' distribution observed early in time, and a 'main' distribution observed later in time. The Arrhenius model was shown to provide a good description of device aging as a function of temperature at a fixed voltage. The Eyring model also appeared to provide a reasonable description of main distribution device aging as a function of temperature and voltage. Circuit diagrams are shown.
Advanced ceramic coating development for industrial/utility gas turbine applications
NASA Technical Reports Server (NTRS)
Andersson, C. A.; Lau, S. K.; Bratton, R. J.; Lee, S. Y.; Rieke, K. L.; Allen, J.; Munson, K. E.
1982-01-01
The effects of ceramic coatings on the lifetimes of metal turbine components and on the performance of a utility turbine, as well as of the turbine operational cycle on the ceramic coatings were determined. When operating the turbine under conditions of constant cooling flow, the first row blades run 55K cooler, and as a result, have 10 times the creep rupture life, 10 times the low cycle fatigue life and twice the corrosion life with only slight decreases in both specific power and efficiency. When operating the turbine at constant metal temperature and reduced cooling flow, both specific power and efficiency increases, with no change in component lifetime. The most severe thermal transient of the turbine causes the coating bond stresses to approach 60% of the bond strengths. Ceramic coating failures was studied. Analytic models based on fracture mechanics theories, combined with measured properties quantitatively assessed both single and multiple thermal cycle failures which allowed the prediction of coating lifetime. Qualitative models for corrosion failures are also presented.
Yousif, Matthew John; Bicos, James
2017-01-01
Background: The glenohumeral joint is the most commonly dislocated joint in the body. Failure rates of capsulolabral repair have been reported to be approximately 8%. Recent focus has been on restoration of the capsulolabral complex by a double-row capsulolabral repair technique in an effort to decrease redislocation rates after arthroscopic capsulolabral repair. Purpose: To present a review of the biomechanical literature comparing single- versus double-row capsulolabral repairs and discuss the previous case series of double-row fixation. Study Design: Narrative review. Methods: A simple review of the literature was performed by PubMed search. Only biomechanical studies comparing single- versus double-row capsulolabral repair were included for review. Only those case series and descriptive techniques with clinical results for double-row repair were included in the discussion. Results: Biomechanical comparisons evaluating the native footprint of the labrum demonstrated significantly superior restoration of the footprint through double-row capsulolabral repair compared with single-row repair. Biomechanical comparisons of contact pressure at the repair interface, fracture displacement in bony Bankart lesion, load to failure, and decreased external rotation (suggestive of increased load to failure) were also significantly in favor of double- versus single-row repair. Recent descriptive techniques and case series of double-row fixation have demonstrated good clinical outcomes; however, no comparative clinical studies between single- and double-row repair have assessed functional outcomes. Conclusion: The superiority of double-row capsulolabral repair versus single-row repair remains uncertain because comparative studies assessing clinical outcomes have yet to be performed. PMID:29230427
Single Parent Adoptions: An Issue of Difficulty and Import for Adoption Agencies.
ERIC Educational Resources Information Center
Rosenberg, Jeffrey
Little theoretical and empirical knowledge is available in the social work field to guide practitioners in the area of single parent adoption. In the context of demographics, the single parent family is now conventional. However there is not yet conclusive research on the success or failure of single parent households. Research has suggested that…
Huang, Zhihong; Sawyer, Douglas B; Troy, Erika L; McEwen, Corissa; Cleator, John H; Murphy, Abigail; Caggiano, Anthony O; Eisen, Andrew; Parry, Tom J
2017-10-01
Neuregulin-1β is a member of the neuregulin family of growth factors and is critically important for normal development and functioning of the heart and brain. A recombinant version of neuregulin-1β, cimaglermin alfa (also known as glial growth factor 2 or GGF2) is being investigated as a possible therapy for heart failure. Previous studies suggest that neuregulin-1β stimulation of skeletal muscle increases glucose uptake and, specifically, sufficient doses of cimaglermin alfa acutely produce hypoglycemia in pigs. Since acute hypoglycemia could be a safety concern, blood glucose changes in the above pig study were further investigated. In addition, basal glucose and glucose disposal were investigated in mice. Finally, as part of standard clinical chemistry profiling in a single ascending-dose human safety study, blood glucose levels were evaluated in patients with heart failure after cimaglermin alfa treatment. A single intravenous injection of cimaglermin alfa at doses of 0.8mg/kg and 2.6mg/kg in mice resulted in a transient reduction of blood glucose concentrations of approximately 20% and 34%, respectively, at 2h after the treatment compared to pre-treatment levels. Similar results were observed in diabetic mice. Treatment with cimaglermin alfa also increased blood glucose disposal following oral challenge in mice. However, no significant alterations in blood glucose concentrations were found in human heart failure patients at 0.5 and 2h after treatment with cimaglermin alfa over an equivalent human dose range, based on body surface area. Taken together, these data indicate strong species differences in blood glucose handling after cimaglermin alfa treatment, and particularly do not indicate that this phenomenon should affect human subjects. Copyright © 2017 Elsevier Inc. All rights reserved.
Speedy routing recovery protocol for large failure tolerance in wireless sensor networks.
Lee, Joa-Hyoung; Jung, In-Bum
2010-01-01
Wireless sensor networks are expected to play an increasingly important role in data collection in hazardous areas. However, the physical fragility of a sensor node makes reliable routing in hazardous areas a challenging problem. Because several sensor nodes in a hazardous area could be damaged simultaneously, the network should be able to recover routing after node failures over large areas. Many routing protocols take single-node failure recovery into account, but it is difficult for these protocols to recover the routing after large-scale failures. In this paper, we propose a routing protocol, referred to as ARF (Adaptive routing protocol for fast Recovery from large-scale Failure), to recover a network quickly after failures over large areas. ARF detects failures by counting the packet losses from parent nodes, and upon failure detection, it decreases the routing interval to notify the neighbor nodes of the failure. Our experimental results indicate that ARF could provide recovery from large-area failures quickly with less packets and energy consumption than previous protocols.
Niat, Alireza Boruzi; Yazdi, Fatmeh Maleknejad; Koohestanian, Niloufar
2012-12-01
To determine the effect of drying agents and adhesive solvents on the bond strength of resin composite to enamel immediately after bleaching. Sixty healthy human premolars were bleached using 15% carbamide peroxide gel and randomly divided into three groups according to the immersing solutions applied immediately after bleaching: 70% alcohol, acetone, and distilled water. Each group was randomly divided into two subgroups according to the adhesives that were applied: an alcohol-based adhesive (Single Bond) and an acetone-based adhesive (One Step). By using rubber washers, composite Z100 was placed onto the enamel and shear bond strength was evaluated in a universal testing machine at a crosshead speed of 1 mm/min. The type of failure was also assessed using a stereomicroscope. The data were statistically analyzed by two-way ANOVA and Tukey's post-hoc test (α = 0.05). Fisher's Exact test was used to evaluate differences in the failure modes. Statistical analysis showed that the bond strength of the distilled water groups was significantly lower than that of the other groups, but the bond strengths of the two groups where a drying agent was applied were similar to that of the unbleached group. The acetone-based adhesive (One Step) provided higher bond strength than did the alcohol-based adhesive (Single Bond) (p < 0.05). There was no interaction between the two variables (p > 0.05). Fisher's Exact test showed there was no significant difference in the failure mode of all the experimental groups (p > 0.05). The application of drying agents improves the bond strength of resin composite to bleached enamel. Furthermore, the acetone-based adhesive used in the study had a higher bond strength to bleached enamel than did the alcohol-based adhesive used.
Detecting failure of climate predictions
Runge, Michael C.; Stroeve, Julienne C.; Barrett, Andrew P.; McDonald-Madden, Eve
2016-01-01
The practical consequences of climate change challenge society to formulate responses that are more suited to achieving long-term objectives, even if those responses have to be made in the face of uncertainty1, 2. Such a decision-analytic focus uses the products of climate science as probabilistic predictions about the effects of management policies3. Here we present methods to detect when climate predictions are failing to capture the system dynamics. For a single model, we measure goodness of fit based on the empirical distribution function, and define failure when the distribution of observed values significantly diverges from the modelled distribution. For a set of models, the same statistic can be used to provide relative weights for the individual models, and we define failure when there is no linear weighting of the ensemble models that produces a satisfactory match to the observations. Early detection of failure of a set of predictions is important for improving model predictions and the decisions based on them. We show that these methods would have detected a range shift in northern pintail 20 years before it was actually discovered, and are increasingly giving more weight to those climate models that forecast a September ice-free Arctic by 2055.
NASA Astrophysics Data System (ADS)
Baró, Jordi; Davidsen, Jörn
2018-03-01
The hypothesis of critical failure relates the presence of an ultimate stability point in the structural constitutive equation of materials to a divergence of characteristic scales in the microscopic dynamics responsible for deformation. Avalanche models involving critical failure have determined common universality classes for stick-slip processes and fracture. However, not all empirical failure processes exhibit the trademarks of criticality. The rheological properties of materials introduce dissipation, usually reproduced in conceptual models as a hardening of the coarse grained elements of the system. Here, we investigate the effects of transient hardening on (i) the activity rate and (ii) the statistical properties of avalanches. We find the explicit representation of transient hardening in the presence of generalized viscoelasticity and solve the corresponding mean-field model of fracture. In the quasistatic limit, the accelerated energy release is invariant with respect to rheology and the avalanche propagation can be reinterpreted in terms of a stochastic counting process. A single universality class can be defined from such analogy, and all statistical properties depend only on the distance to criticality. We also prove that interevent correlations emerge due to the hardening—even in the quasistatic limit—that can be interpreted as "aftershocks" and "foreshocks."
Sorensen, Eric P; Fanucci, Kristina A; Saraiya, Ami; Volf, Eva; Au, Shiu-chung; Argobi, Yahya; Mansfield, Ryan; Gottlieb, Alice B
2015-08-01
Additional studies are needed to examine the efficacy of ustekinumab in psoriasis patients who have previously been exposed to tumor necrosis factor inhibitors (TNFi). To examine the predictive effect of TNFi primary failure and the number of TNFi exposures on the efficacy of ustekinumab in psoriasis treatment. This retrospective study examined 44 psoriasis patients treated at the Tufts Medical Center Department of Dermatology between January 2008 and July 2014. Patients were selected if they were treated with ustekinumab and had ≥ 1 previous TNFi exposure. The following subgroups were compared: patients with vs without a previous TNFi primary failure, and patients with one vs multiple previous TNFi exposures. The efficacy measure used was the previously validated Simple Measure for Assessing Psoriasis Activity (S-MAPA), which is calculated by the product of the body surface area and physician global assessment. The primary outcome was the percentage improvement S-MAPA from course baseline at week 12 of ustekinumab treatment. Secondary outcomes were the psoriasis clearance, primary failure, and secondary failure rates with ustekinumab treatment. Patients with a previous TNFi primary failure had a significantly lower percentage improvement in S-MAPA score at week 12 of ustekinumab treatment compared with patients without TNFi primary failure (36.2% vs 61.1%, P=.027). Multivariate analysis demonstrated that this relationship was independent of patient demographics and medical comorbidities. Patients with multiple TNFi exposures had a non-statistically significant lower percentage S-MAPA improvement at week 12 (40.5% vs 52.9%, P=.294) of ustekinumab treatment compared with patients with a single TNFi exposure. Among psoriasis patients previously exposed to TNFi, a history of a previous TNFi primary failure predicts a decreased response to ustekinumab independent of patient demographics and medical comorbidities.
Murillo, Wendy; de Rivera, I L; Parham, L; Jovel, E; Palou, E; Karlsson, A C; Albert, J
2010-02-01
The Honduran HIV/AIDS Program began to scale up access to HIV therapy in 2002. Up to May 2008, more than 6000 patients received combination antiretroviral therapy (cART). As HIV drug resistance is the major obstacle for effective treatment, the purpose of this study was to assess the prevalence of antiretroviral drug resistance in Honduran HIV-1-infected individuals. We collected samples from 138 individuals (97 adults and 41 children) on cART with virological, immunological or clinical signs of treatment failure. HIV-1 pol sequences were obtained using an in-house method. Resistance mutations were identified according to the 2007 International AIDS Society (IAS)-USA list and predicted susceptibility to cART was scored using the ANRS algorithm. Resistance mutations were detected in 112 patients (81%), 74% in adults and 98% in children. Triple-, dual- and single-class drug resistance was documented in 27%, 43% and 11% of the study subjects, respectively. Multiple logistic regression showed that resistance was independently associated with type of treatment failure [virological failure (odds ratio (OR) = 1) vs. immunological failure (OR = 0.11; 95% confidence interval (CI) 0.030-0.43) vs. clinical failure (OR = 0.037; 95% CI 0.0063-0.22)], route of transmission (OR = 42.8; 95% CI 3.73-491), and years on therapy (OR = 1.81; 95% CI 1.11-2.93). The prevalence of antiretroviral resistance was high in Honduran HIV-infected patients with signs of treatment failure. A majority of study subjects showed dual- or triple-class resistance to nucleoside reverse transcriptase inhibitors, nonnucleoside reverse transcriptase inhibitors and protease inhibitors. Virologically defined treatment failure was a strong predictor of resistance, indicating that viral load testing is needed to correctly identify patients with treatment failure attributable to resistance.
VanSuch, Monica; Naessens, James M; Stroebel, Robert J; Huddleston, Jeanne M; Williams, Arthur R
2006-01-01
Background Most nationally standardised quality measures use widely accepted evidence‐based processes as their foundation, but the discharge instruction component of the United States standards of Joint Commission on Accreditation of Healthcare Organizations heart failure core measure appears to be based on expert opinion alone. Objective To determine whether documentation of compliance with any or all of the six required discharge instructions is correlated with readmissions to hospital or mortality. Research design A retrospective study at a single tertiary care hospital was conducted on randomly sampled patients hospitalised for heart failure from July 2002 to September 2003. Participants Applying the Joint Commission on Accreditation of Healthcare Organizations criteria, 782 of 1121 patients were found eligible to receive discharge instructions. Eligibility was determined by age, principal diagnosis codes and discharge status codes. Measures The primary outcome measures are time to death and time to readmission for heart failure or readmission for any cause and time to death. Results In all, 68% of patients received all instructions, whereas 6% received no instructions. Patients who received all instructions were significantly less likely to be readmitted for any cause (p = 0.003) and for heart failure (p = 0.035) than those who missed at least one type of instruction. Documentation of discharge instructions is correlated with reduced readmission rates. However, there was no association between documentation of discharge instructions and mortality (p = 0.521). Conclusions Including discharge instructions among other evidence‐based heart failure core measures appears justified. PMID:17142589
SU-E-T-495: Neutron Induced Electronics Failure Rate Analysis for a Single Room Proton Accelerator
DOE Office of Scientific and Technical Information (OSTI.GOV)
Knutson, N; DeWees, T; Klein, E
2014-06-01
Purpose: To determine the failure rate as a function of neutron dose of the range modulator's servo motor controller system (SMCS) while shielded with Borated Polyethylene (BPE) and unshielded in a single room proton accelerator. Methods: Two experimental setups were constructed using two servo motor controllers and two motors. Each SMCS was then placed 30 cm from the end of the plugged proton accelerator applicator. The motor was then turned on and observed from outside of the vault while being irradiated to known neutron doses determined from bubble detector measurements. Anytime the motor deviated from the programmed motion a failuremore » was recorded along with the delivered dose. The experiment was repeated using 9 cm of BPE shielding surrounding the SMCS. Results: Ten SMCS failures were recorded in each experiment. The dose per monitor unit for the unshielded SMCS was 0.0211 mSv/MU and 0.0144 mSv/MU for the shielded SMCS. The mean dose to produce a failure for the unshielded SMCS was 63.5 ± 58.3 mSv versus 17.0 ±12.2 mSv for the shielded. The mean number of MUs between failures were 2297 ± 1891 MU for the unshielded SMCS and 2122 ± 1523 MU for the shielded. A Wilcoxon Signed Ranked test showed the dose between failures were significantly different (P value = 0.044) while the number of MUs between failures were not (P value = 1.000). Statistical analysis determined a SMCS neutron dose of 5.3 mSv produces a 5% chance of failure. Depending on the workload and location of the SMCS, this failure rate could impede clinical workflow. Conclusion: BPE shielding was shown to not reduce the average failure of the SMCS and relocation of the system outside of the accelerator vault was required to lower the failure rate enough to avoid impeding clinical work flow.« less
Niraj, G; Kelkar, Aditi; Hart, Elaine; Kaushik, Vipul; Fleet, Danny; Jameson, John
2015-11-01
Transversus abdominis plane (TAP) blocks have been reported to be an effective method of providing analgesia after abdominal surgery. To perform a prospective audit on the effectiveness of a novel technique of providing continuous transversus abdominis plane (TAP) analgesia in patients undergoing emergency and elective abdominal surgery. Prospective single center audit over a 3-year period. University hospital. One hundred twenty-four American Society of Anesthesiologists I to IV adult patients presenting for elective as well as emergency abdominal surgery in whom epidural analgesia was contraindicated or refused. Four quadrant TAP blocks and continuous TAP analgesia. Numerical rating scale pain scores at rest and on coughing, nausea scores, satisfaction scores, complications, frequency of analgesia failure, therapeutic failure with continuous TAP analgesia and opioid consumption. One hundred twenty-four patients who received continuous TAP analgesia were audited. This included 34 patients for elective open surgery, 36 patients for emergency laparotomy, and 54 patients who underwent elective laparoscopic colorectal surgery. Surgical incision was within the dermatomal limit of the block in 70% of the patients (88/124). Therapeutic failure with the technique was 10%. Frequency of analgesic failure over the 48-hour period was none in 39% and below 5 episodes in 57%. Four quadrant transversus abdominis plane blocks and continuous TAP analgesia is an effective technique for providing postoperative analgesia after abdominal surgery. It has the potential to be used as a sole analgesic technique when the surgical incision is within its dermatomal limit. Copyright © 2015 Elsevier Inc. All rights reserved.
Homer, Michael V.; Charo, Lindsey M.; Natarajan, Loki; Haunschild, Carolyn; Chung, Karine; Mao, Jun J.; DeMichele, Angela M.; Su, H. Irene
2016-01-01
Objective To determine if inter-individual genetic variation in single nucleotide polymorphisms related to age at natural menopause are associated with risk of ovarian failure in breast cancer survivors. Methods A prospective cohort of 169 premenopausal breast cancer survivors recruited at diagnosis with Stages 0 to III disease were followed longitudinally for menstrual pattern via self-reported daily menstrual diaries. Participants were genotyped for 13 single nucleotide polymorphisms (SNPs) previously found to be associated with age at natural menopause: EXO1, TLK1, HELQ, UIMC1, PRIM1, POLG, TMEM224, BRSK1, and MCM8. A risk variable summed the total number of risk alleles in each participant. The association between individual genotypes, as well as the risk variable, and time to ovarian failure (> 12 months of amenorrhea) was tested using time-to-event methods. Results Median age at enrollment was 40.5 years old (range 20.6–46.1). The majority of participants were white (69%) and underwent chemotherapy (76%). Thirty-eight participants (22%) experienced ovarian failure. None of the candidate SNPs or the summary risk variable were significantly associated with time to ovarian failure. Sensitivity analysis restricted to whites or only to participants receiving chemotherapy yielded similar findings. Older age, chemotherapy exposure and lower BMI were related to shorter time to ovarian failure. Conclusions Thirteen previously identified genetic variants associated with time to natural menopause were not related to timing of ovarian failure in breast cancer survivors. PMID:28118297
Rate-weakening friction characterizes both slow sliding and catastrophic failure of landslides.
Handwerger, Alexander L; Rempel, Alan W; Skarbek, Rob M; Roering, Joshua J; Hilley, George E
2016-09-13
Catastrophic landslides cause billions of dollars in damages and claim thousands of lives annually, whereas slow-moving landslides with negligible inertia dominate sediment transport on many weathered hillslopes. Surprisingly, both failure modes are displayed by nearby landslides (and individual landslides in different years) subjected to almost identical environmental conditions. Such observations have motivated the search for mechanisms that can cause slow-moving landslides to transition via runaway acceleration to catastrophic failure. A similarly diverse range of sliding behavior, including earthquakes and slow-slip events, occurs along tectonic faults. Our understanding of these phenomena has benefitted from mechanical treatments that rely upon key ingredients that are notably absent from previous landslide descriptions. Here, we describe landslide motion using a rate- and state-dependent frictional model that incorporates a nonlocal stress balance to account for the elastic response to gradients in slip. Our idealized, one-dimensional model reproduces both the displacement patterns observed in slow-moving landslides and the acceleration toward failure exhibited by catastrophic events. Catastrophic failure occurs only when the slip surface is characterized by rate-weakening friction and its lateral dimensions exceed a critical nucleation length [Formula: see text] that is shorter for higher effective stresses. However, landslides that are extensive enough to fall within this regime can nevertheless slide slowly for months or years before catastrophic failure. Our results suggest that the diversity of slip behavior observed during landslides can be described with a single model adapted from standard fault mechanics treatments.
Rate-weakening friction characterizes both slow sliding and catastrophic failure of landslides
Handwerger, Alexander L.; Rempel, Alan W.; Skarbek, Rob M.; Roering, Joshua J.; Hilley, George E.
2016-01-01
Catastrophic landslides cause billions of dollars in damages and claim thousands of lives annually, whereas slow-moving landslides with negligible inertia dominate sediment transport on many weathered hillslopes. Surprisingly, both failure modes are displayed by nearby landslides (and individual landslides in different years) subjected to almost identical environmental conditions. Such observations have motivated the search for mechanisms that can cause slow-moving landslides to transition via runaway acceleration to catastrophic failure. A similarly diverse range of sliding behavior, including earthquakes and slow-slip events, occurs along tectonic faults. Our understanding of these phenomena has benefitted from mechanical treatments that rely upon key ingredients that are notably absent from previous landslide descriptions. Here, we describe landslide motion using a rate- and state-dependent frictional model that incorporates a nonlocal stress balance to account for the elastic response to gradients in slip. Our idealized, one-dimensional model reproduces both the displacement patterns observed in slow-moving landslides and the acceleration toward failure exhibited by catastrophic events. Catastrophic failure occurs only when the slip surface is characterized by rate-weakening friction and its lateral dimensions exceed a critical nucleation length h* that is shorter for higher effective stresses. However, landslides that are extensive enough to fall within this regime can nevertheless slide slowly for months or years before catastrophic failure. Our results suggest that the diversity of slip behavior observed during landslides can be described with a single model adapted from standard fault mechanics treatments. PMID:27573836
Dual renin-angiotensin-aldosterone blockade: promises and pitfalls.
Chrysant, Steven G; Chrysant, George S
2015-01-01
Single renin-angiotensin-aldosterone system (RAAS) blockade has been shown to be effective and safe for the treatment of hypertension, coronary heart disease (CHD), heart failure (HF), diabetes, and chronic kidney disease (CKD) with proteinuria. Due to the action of RAAS blockers at various levels of the RAAS cascade, it was hypothesized that dual RAAS blockade would result in more complete inhibition of angiotensin II (Ang II) production and be more effective in blocking its detrimental cardiovascular remodeling effects. Unfortunately, several clinical trials in patients with hypertension, CHD, HF, and CKD with proteinuria have demonstrated no superiority of dual versus single RAAS blockade, but a higher incidence of adverse events. Based on these findings, dual RAAS blockade is no longer recommended for the routine treatment of various cardiovascular diseases, except diabetic nephropathy with proteinuria and HF with reduced ejection fraction. All the new information gathered from studies within the last 3 years will be presented in this review.
Di Bella, Claudia; Dozza, Barbara; Frisoni, Tommaso; Cevolani, Luca; Donati, Davide
2010-11-01
Unicameral bone cysts are benign lesions that usually spontaneously regress with skeletal maturity; however, the high risk of pathologic fractures often justifies treatment that could reinforce a weakened bone cortex. Various treatments have been proposed but there is no consensus regarding the best procedure. We compared the healing rates and failures of two methods of cure based on multiple injections of corticosteroid or a single injection of demineralized bone matrix (DBM) in association with bone marrow concentrate (BMC). We retrospectively reviewed 184 patients who had one of the two treatments for unicameral bone cysts with cortical erosion. Clinical records were reviewed for treatment failures and radiographs for healing in all patients. The minimum followup was 12 months for the Steroids Group (mean, 48 months; range, 12-120 months) and 12 months for the DBM + BMC Group (mean, 20 months; range, 12-28 months). After one treatment we observed a lower healing rate of cysts treated with multiple injections of steroids compared with the healing after the first injection of DBM + BMC (21% versus 58%, respectively). At last followup, 38% healed with steroids and 71% with DBM + BMC. The rate of failure after one steroid injection was higher than after a single injection of BDM + BMC (63% versus 24%, respectively). We observed no difference in fracture rates after treatment between the two groups. A single injection of DBM added with autologous bone marrow concentrate appears to provide a higher healing rate with a lower number of failures compared with a single injection of steroids.
Single-Dose Absorption and Pharmacokinetics of WR 6026. Phase 1
1988-08-01
glucose, uric acid , calcium, phosphate, 8 total protein, albumin, direct and total bilirubin, aspartate aminotransferase (AST), alanine aminotransferase...Fitted Equation 42 Table 8 Elimination Rate Constant and Plasma Half-Life of WK 6026 43 Table 9 Pharmacokinetic Data for Individual Subjects 44 Table 10...failure rate of antimony compounds and the toxicity of other effective drugs, there is a clear need for development of alternative drugs. WR 6026 (8-(6
Effect of changing slope of grain on ash, maple, and yellow birch in bending strength
David E. Kretschmann; James J. Bridwell; Timothy C. Nelson
2010-01-01
The presence of slope of grain (SoG) in wood can severely reduce the bending strength in wood. Failure to recognize the degree to which SoG can reduce strength can be catastrophic if wood is in single member use. In the United States, a growing concern in the sport of baseball relates to the high frequency of multi-piece broken wood bats. It was observed that hard...
Pharmacokinetics of brotizolam in renal failure
Evers, J.; Renner, E.; Bechtel, W. D.
1983-01-01
1 Kinetics of brotizolam (0.25 mg) were studied in patients with different degrees of renal failure after single and repeated oral ingestion. Serum levels were analysed by radio-immunoassay. 2 Patients were divided into three groups according to their renal function, i.e. creatinine clearance values of 45-80, 15-45, or less than 15 ml/min. 3 The mean elimination half-life was 6.9-8.15 h, with a considerable variation of the peak concentration and elimination half-life in slight to moderate renal failure. There was no delay in elimination in severe renal failure and there was no drug accumulation. 4 No dose adjustment is necessary for brotizolam in renal failure. PMID:6661376
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sethi, Roshan V.; Giantsoudi, Drosoula; Raiford, Michael
2014-03-01
Purpose: The pattern of failure in medulloblastoma patients treated with proton radiation therapy is unknown. For this increasingly used modality, it is important to ensure that outcomes are comparable to those in modern photon series. It has been suggested this pattern may differ from photons because of variations in linear energy transfer (LET) and relative biological effectiveness (RBE). In addition, the use of matching fields for delivery of craniospinal irradiation (CSI) may influence patterns of relapse. Here we report the patterns of failure after the use of protons, compare it to that in the available photon literature, and determine themore » LET and RBE values in areas of recurrence. Methods and Materials: Retrospective review of patients with medulloblastoma treated with proton radiation therapy at Massachusetts General Hospital (MGH) between 2002 and 2011. We documented the locations of first relapse. Discrete failures were contoured on the original planning computed tomography scan. Monte Carlo calculation methods were used to estimate the proton LET distribution. Models were used to estimate RBE values based on the LET distributions. Results: A total of 109 patients were followed for a median of 38.8 months (range, 1.4-119.2 months). Of the patients, 16 experienced relapse. Relapse involved the supratentorial compartment (n=8), spinal compartment (n=11), and posterior fossa (n=5). Eleven failures were isolated to a single compartment; 6 failures in the spine, 4 failures in the supratentorium, and 1 failure in the posterior fossa. The remaining patients had multiple sites of disease. One isolated spinal failure occurred at the spinal junction of 2 fields. None of the 70 patients treated with an involved-field-only boost failed in the posterior fossa outside of the tumor bed. We found no correlation between Monte Carlo-calculated LET distribution and regions of recurrence. Conclusions: The most common site of failure in patients treated with protons for medulloblastoma was outside of the posterior fossa. The most common site for isolated local failure was the spine. We recommend consideration of spinal imaging in follow-up and careful attention to dose distribution in the spinal junction regions. Development of techniques that do not require field matching may be of benefit. We did not identify a direct correlation between lower LET values and recurrence in medulloblastoma patients treated with proton therapy. Patterns of failure do not appear to differ from those in patients treated with photon therapy.« less
Modeling Progressive Failure of Bonded Joints Using a Single Joint Finite Element
NASA Technical Reports Server (NTRS)
Stapleton, Scott E.; Waas, Anthony M.; Bednarcyk, Brett A.
2010-01-01
Enhanced finite elements are elements with an embedded analytical solution which can capture detailed local fields, enabling more efficient, mesh-independent finite element analysis. In the present study, an enhanced finite element is applied to generate a general framework capable of modeling an array of joint types. The joint field equations are derived using the principle of minimum potential energy, and the resulting solutions for the displacement fields are used to generate shape functions and a stiffness matrix for a single joint finite element. This single finite element thus captures the detailed stress and strain fields within the bonded joint, but it can function within a broader structural finite element model. The costs associated with a fine mesh of the joint can thus be avoided while still obtaining a detailed solution for the joint. Additionally, the capability to model non-linear adhesive constitutive behavior has been included within the method, and progressive failure of the adhesive can be modeled by using a strain-based failure criteria and re-sizing the joint as the adhesive fails. Results of the model compare favorably with experimental and finite element results.
Porosity Evolution in a Creeping Single Crystal (Preprint)
2012-08-01
1] indicated that the growth of initially present processing induced voids in a nickel based single crystal superalloy played a significant role in...processing induced voids in a nickel based single crystal superalloy played a significant role in limiting creep life. Also, creep tests on single...experimental observations of creep deformation and failure of a nickel based single crystal superalloy, [1, 2]. Metallographic observations have shown that Ni
Gajendran, Varun K; Szabo, Robert M; Myo, George K; Curtiss, Shane B
2009-12-01
Open or unstable metacarpal fractures frequently require open reduction and internal fixation. Locking plate technology has improved fixation of unstable fractures in certain settings. In this study, we hypothesized that there would be a difference in strength of fixation using double-row locking plates compared with single- and double-row non-locking plates in comminuted metacarpal fractures. We tested our hypothesis in a gap metacarpal fracture model simulating comminution using fourth-generation, biomechanical testing-grade composite sawbones. The metacarpals were divided into 6 groups of 15 bones each. Groups 1 and 4 were plated with a standard 6-hole, 2.3-mm plate in AO fashion. Groups 2 and 5 were plated with a 6-hole double-row 3-dimensional non-locking plate with bicortical screws aimed for convergence. Groups 3 and 6 were plated with a 6-hole double-row 3-dimensional locking plate with unicortical screws. The plated metacarpals were then tested to failure against cantilever apex dorsal bending (groups 1-3) and torsion (groups 4-6). The loads to failure in groups 1 to 3 were 198 +/- 18, 223 +/- 29, and 203 +/- 19 N, respectively. The torques to failure in groups 4 to 6 were 2,033 +/- 155, 3,190 +/- 235, and 3,161 +/- 268 N mm, respectively. Group 2 had the highest load to failure, whereas groups 5 and 6 shared the highest torques to failure (p < .05). Locking and non-locking double-row plates had equivalent bending and torsional stiffness, significantly higher than observed for the single-row non-locking plate. No other statistical differences were noted between groups. When subjected to the physiologically relevant forces of apex dorsal bending and torsion in a comminuted metacarpal fracture model, double-row 3-dimensional non-locking plates provided superior stability in bending and equivalent stability in torsion compared with double-row 3-dimensional locking plates, whereas single-row non-locking plates provided the least stability.
Jackson, Timothy J; Adamson, Gregory J; Peterson, Alexander; Patton, John; McGarry, Michelle H; Lee, Thay Q
2013-05-01
Many ulnar collateral ligament (UCL) reconstruction techniques have been created and biomechanically tested. Single-bundle reconstructions aim to re-create the important anterior bundle of the UCL. To date, no technique has utilized suspensory fixation on the ulnar and humeral sides to create a single-bundle reconstruction. The bisuspensory technique will restore valgus laxity to its native state, with comparable load-to-failure characteristics to the docking technique. Controlled laboratory study. Six matched pairs of fresh-frozen cadaveric elbows were randomized to undergo UCL reconstruction using either the docking technique or a novel single-bundle bisuspensory technique. Valgus laxity and rotation measurements were quantified using a MicroScribe 3DLX digitizer at various flexion angles for the native ligament, transected ligament, and 1 of the 2 tested reconstructed ligaments. Laxity testing was performed from maximum extension to 120° of flexion. Each reconstruction was then tested to failure, and the method of failure was recorded. Valgus laxity was restored to the intact state at all degrees of elbow flexion for both the docking and bisuspensory techniques. In load-to-failure testing, there was no significant difference with regard to stiffness, ultimate torque, ultimate torque angle, energy absorbed, and applied moment to reach 10° of valgus. Yield torques for the bisuspensory and docking reconstructions were 18.7 ± 7.8 N·m and 18.6 ± 4.4 N·m, respectively (P = .95). The ultimate torque for the bisuspensory technique measured 26.5 ± 9.2 N·m and for the docking technique measured 25.1 ± 7.1 N·m (P = .78). The bisuspensory fixation technique, a reproducible single-bundle reconstruction, was able to restore valgus laxity to the native state, with similar load-to-failure characteristics as the docking technique. This reconstruction technique could be considered in a clinical setting as a primary method of UCL reconstruction or as a backup fixation method should intraoperative complications occur.
Development Testing and Subsequent Failure Investigation of a Spring Strut Mechanism
NASA Technical Reports Server (NTRS)
Dervan, Jared; Robertson, Brandan; Staab, Lucas; Culberson, Michael; Pellicciotti, Joseph
2014-01-01
The NASA Engineering and Safety Center (NESC) and Lockheed Martin (LM) performed random vibration testing on a single spring strut development unit to assess its ability to withstand qualification level random vibration environments. Failure of the strut while exposed to random vibration resulted in a follow-on failure investigation, design changes, and additional development tests. This paper focuses on the results of the failure investigations referenced in detail in the NESC final report [1] including identified lessons learned to aid in future design iterations of the spring strut and to help other mechanism developers avoid similar pitfalls.
Development Testing and Subsequent Failure Investigation of a Spring Strut Mechanism
NASA Technical Reports Server (NTRS)
Dervan, Jared; Robertson, Brandon; Staab, Lucas; Culberson, Michael; Pellicciotti, Joseph
2014-01-01
The NASA Engineering and Safety Center (NESC) and Lockheed Martin (LM) performed random vibration testing on a single spring strut development unit to assess its ability to withstand qualification level random vibration environments. Failure of the strut while exposed to random vibration resulted in a follow-on failure investigation, design changes, and additional development tests. This paper focuses on the results of the failure investigations referenced in detail in the NESC final report including identified lessons learned to aid in future design iterations of the spring strut and to help other mechanism developers avoid similar pitfalls.
Actuator digital interface unit (AIU). [control units for space shuttle data system
NASA Technical Reports Server (NTRS)
1973-01-01
Alternate versions of the actuator interface unit are presented. One alternate is a dual-failure immune configuration which feeds a look-and-switch dual-failure immune hydraulic system. The other alternate is a single-failure immune configuration which feeds a majority voting hydraulic system. Both systems communicate with the data bus through data terminals dedicated to each user subsystem. Both operational control data and configuration control information are processed in and out of the subsystem via the data terminal which yields the actuator interface subsystem, self-managing within its failure immunity capability.
NASA Astrophysics Data System (ADS)
Li, Xin; Zhang, Lu; Tang, Ying; Huang, Shanguo
2018-03-01
The light-tree-based optical multicasting (LT-OM) scheme provides a spectrum- and energy-efficient method to accommodate emerging multicast services. Some studies focus on the survivability technologies for LTs against a fixed number of link failures, such as single-link failure. However, a few studies involve failure probability constraints when building LTs. It is worth noting that each link of an LT plays different important roles under failure scenarios. When calculating the failure probability of an LT, the importance of its every link should be considered. We design a link importance incorporated failure probability measuring solution (LIFPMS) for multicast LTs under independent failure model and shared risk link group failure model. Based on the LIFPMS, we put forward the minimum failure probability (MFP) problem for the LT-OM scheme. Heuristic approaches are developed to address the MFP problem in elastic optical networks. Numerical results show that the LIFPMS provides an accurate metric for calculating the failure probability of multicast LTs and enhances the reliability of the LT-OM scheme while accommodating multicast services.
2016-12-01
December 2016 3. REPORT TYPE AND DATES COVERED Master’s thesis 4. TITLE AND SUBTITLE A STUDY ON THE FAILURE OF CONVENTIONAL DETERRENCE: THE CASE ...Approved for public release. Distribution is unlimited A STUDY ON THE FAILURE OF CONVENTIONAL DETERRENCE: THE CASE STUDY OF THE BOMBARDMENT OF...necessary to analyze these diverse elements comprehensively. E. RESEARCH DESIGN This thesis focuses on a single case study about the bombardment of
Tsiouris, Athanasios; Paone, Gaetano; Nemeh, Hassan W; Brewer, Robert J; Borgi, Jamil; Hodari, Arielle; Morgan, Jeffrey A
2015-01-01
Continuous-flow (CF) left ventricular assist devices (LVADs) have become the standard of care for patients with advanced heart failure refractory to optimal medical therapy. The goal of this study was to review our 7 year single institutional experience with CF LVADs. Mean age was 50.4 + 12.5 (17-69) years for bridge-to-transplantation (BTT) patients and 57.6 + 10.4 (31-81) years for destination therapy (DT) patients (p < 0.001). Overall, 38 patients (26%) were female and 58 (41%) were African American. Etiology of heart failure was ischemic in 54 patients (37%) and nonischemic in 93 patients (63%). Overall survival at 30 days, 6 months, 12 months, and 2 years was 93%, 89%, 84%, and 81%, respectively. Gastrointestinal bleeding (GIB) was the most common complication (24%), followed by stroke (18%), right ventricular (RV) failure (18%), ventilator-dependent respiratory failure (10%), reoperation for bleeding (10%), and driveline infection (9%). These data demonstrate excellent survival with low mortality for both BTT and DT patients on long-term LVAD support. However, for LVAD therapy to become the gold standard for long-term treatment of end-stage heart failure and a plausible alternative to heart transplantation, we need to continue to improve the incidence of frequent postoperative complications, such as RV failure, driveline infections, strokes, and GIB.
NASA Technical Reports Server (NTRS)
Rogallo, Vernon L.; Yaggy, Paul F.; McCloud, John L., III
1954-01-01
An investigation of a decoupler and a controlled-feathering device incorporated with the YT-56A turboprop engine has been made to determine the effectiveness of these devices in reducing the high negative thrust (drag) which accompanies power failure of this type of engine. Power failures were simulated by fuel cut-off, both without either device free to operate, and with each device free to operate singly. The investigation was made through an airspeed range from 50 to 230 mph. It was found that with neither device free to operate, the drag levels realized after power failures at airspeeds above 170 mph would impose vertical tail loads higher than those allowable for the YC-130, the airplane for which the test power package was designed. These levels were reached in approximately one second. The maximum drag realized after power failure was not appreciably altered by the use of the decoupler although the decoupler did put a limit on the duration of the peak drag. The controlled-feathering device maintained a level of essentially zero drag after power failure. The use of the decoupler in the YT-56A engine complicates windmilling air-starting procedures and makes it necessary to place operating restrictions on the engine to assure safe flight at low-power conditions,
Ellinas, Christos; Allan, Neil; Durugbo, Christopher; Johansson, Anders
2015-01-01
Current societal requirements necessitate the effective delivery of complex projects that can do more while using less. Yet, recent large-scale project failures suggest that our ability to successfully deliver them is still at its infancy. Such failures can be seen to arise through various failure mechanisms; this work focuses on one such mechanism. Specifically, it examines the likelihood of a project sustaining a large-scale catastrophe, as triggered by single task failure and delivered via a cascading process. To do so, an analytical model was developed and tested on an empirical dataset by the means of numerical simulation. This paper makes three main contributions. First, it provides a methodology to identify the tasks most capable of impacting a project. In doing so, it is noted that a significant number of tasks induce no cascades, while a handful are capable of triggering surprisingly large ones. Secondly, it illustrates that crude task characteristics cannot aid in identifying them, highlighting the complexity of the underlying process and the utility of this approach. Thirdly, it draws parallels with systems encountered within the natural sciences by noting the emergence of self-organised criticality, commonly found within natural systems. These findings strengthen the need to account for structural intricacies of a project's underlying task precedence structure as they can provide the conditions upon which large-scale catastrophes materialise.
Larsen, Jacob M; Hjortshøj, Søren P; Nielsen, Jens C; Johansen, Jens B; Petersen, Helen H; Haarbo, Jens; Johansen, Martin B; Thøgersen, Anna Margrethe
2016-03-01
The best choice of defibrillator lead in patients with routine implantable cardioverter-defibrillator (ICD) is not settled. Traditionally, most physicians prefer dual-coil leads but the use of single-coil leads is increasing. The purpose of this study was to compare clinical outcomes in patients with single- and dual-coil leads. All 4769 Danish patients 18 years or older with first-time ICD implants from 2007 to 2011 were included from the Danish Pacemaker and ICD Register. Defibrillator leads were 38.9% single-coil leads and 61.1% dual-coil leads. The primary end point was all-cause mortality. Secondary end points were lowest successful energy at implant defibrillation testing, first shock failure in spontaneous arrhythmias, structural lead failure, and lead extraction outcomes. Single-coil leads were associated with lower all-cause mortality with an adjusted hazard ratio of 0.85 (95% confidence interval 0.73-0.99; P = .04). This finding was robust in a supplementary propensity score-matched analysis. However, dual-coil leads were used in patients with slightly higher preimplant morbidity, making residual confounding by indication the most likely explanation for the observed association between lead type and mortality. The lowest successful defibrillation energy was higher using single-coil leads (23.2 ± 4.3 J vs 22.1 ± 3.9 J; P < .001). No significant differences were observed for other secondary end points showing high shock efficacies and low rates of lead failures and extraction complications. Shock efficacy is high for modern ICD systems. The choice between single-coil and dual-coil defibrillator leads is unlikely to have a clinically significant impact on patient outcomes in routine ICD implants. Copyright © 2016 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
Multiple Fault Isolation in Redundant Systems
NASA Technical Reports Server (NTRS)
Pattipati, Krishna R.; Patterson-Hine, Ann; Iverson, David
1997-01-01
Fault diagnosis in large-scale systems that are products of modern technology present formidable challenges to manufacturers and users. This is due to large number of failure sources in such systems and the need to quickly isolate and rectify failures with minimal down time. In addition, for fault-tolerant systems and systems with infrequent opportunity for maintenance (e.g., Hubble telescope, space station), the assumption of at most a single fault in the system is unrealistic. In this project, we have developed novel block and sequential diagnostic strategies to isolate multiple faults in the shortest possible time without making the unrealistic single fault assumption.
Multiple Fault Isolation in Redundant Systems
NASA Technical Reports Server (NTRS)
Pattipati, Krishna R.
1997-01-01
Fault diagnosis in large-scale systems that are products of modem technology present formidable challenges to manufacturers and users. This is due to large number of failure sources in such systems and the need to quickly isolate and rectify failures with minimal down time. In addition, for fault-tolerant systems and systems with infrequent opportunity for maintenance (e.g., Hubble telescope, space station), the assumption of at most a single fault in the system is unrealistic. In this project, we have developed novel block and sequential diagnostic strategies to isolate multiple faults in the shortest possible time without making the unrealistic single fault assumption.
NASA Technical Reports Server (NTRS)
Naumann, R. J.; Oran, W. A.; Whymark, R. R.; Rey, C.
1981-01-01
The single axis acoustic levitator that was flown on SPAR VI malfunctioned. The results of a series of tests, analyses, and investigation of hypotheses that were undertaken to determine the probable cause of failure are presented, together with recommendations for future flights of the apparatus. The most probable causes of the SPAR VI failure were lower than expected sound intensity due to mechanical degradation of the sound source, and an unexpected external force that caused the experiment sample to move radially and eventually be lost from the acoustic energy well.
Biomechanical evaluation of a single-row versus double-row repair for complete subscapularis tears.
Wellmann, Mathias; Wiebringhaus, Philipp; Lodde, Ina; Waizy, Hazibullah; Becher, Christoph; Raschke, Michael J; Petersen, Wolf
2009-12-01
The purpose of the study was to compare a single-row repair and a double-row repair technique for the specific characteristics of a complete subscapularis lesion. Ten pairs of human cadaveric shoulder human shoulder specimens were tested for stiffness and ultimate tensile strength of the intact tendons in a load to failure protocol. After a complete subscapularis tear was provoked, the specimens were assigned to two treatment groups: single-row repair (1) and a double-row repair using a "suture bridge" technique (2). After repair cyclic loading a subsequent load to failure protocol was performed to determine the ultimate tensile load, the stiffness and the elongation behaviour of the reconstructions. The intact subscapularis tendons had a mean stiffness of 115 N/mm and a mean ultimate load of 720 N. The predominant failure mode of the intact tendons was a tear at the humeral insertion site (65%). The double-row technique restored 48% of the ultimate load of the intact tendons (332 N), while the single-row technique revealed a significantly lower ultimate load of 244 N (P = 0.001). In terms of the stiffness, the double-row technique showed a mean stiffness of 81 N/mm which is significantly higher compared to the stiffness of the single-row repairs of 55 N/mm (P = 0.001). The double-row technique has been shown to be stronger and stiffer when compared to a conventional single-row repair. Therefore, this technique is recommended from a biomechanical point of view irrespectively if performed by an open or arthroscopic approach.
Cené, Crystal W; Haymore, Laura Beth; Lin, Feng-Chang; Laux, Jeffrey; Jones, Christine Delong; Wu, Jia-Rong; DeWalt, Darren; Pignone, Mike; Corbie-Smith, Giselle
2015-03-01
To examine the association between frequency of family member accompaniment to medical visits and heart failure (HF) self-care maintenance and management and to determine whether associations are mediated through satisfaction with provider communication. Cross-sectional survey of 150 HF patients seen in outpatient clinics. HF self-care maintenance and management were assessed using the Self-Care of Heart Failure Index. Satisfaction with provider communication was assessed using a single question originally included in the American Board of Internal Medicine Patient Satisfaction Questionnaire. Frequency of family member accompaniment to visits was assessed using a single-item question. We performed regression analyses to examine associations between frequency of accompaniment and outcomes. Mediation analysis was conducted using MacKinnon's criteria. Overall, 61% reported accompaniment by family members to some/most/every visit. Accompaniment to some/most/every visit was associated with higher self-care maintenance (β = 6.4, SE 2.5; p = 0.01) and management (β = 12.7, SE 4.9; p = 0.01) scores. Satisfaction with provider communication may mediate the association between greater frequency of accompaniment to visits and self-care maintenance (1.092; p = 0.06) and self-care management (1.428; p = 0.13). Accompaniment to medical visits is associated with better HF self-care maintenance and management, and this effect may be mediated through satisfaction with provider communication. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
NASA Astrophysics Data System (ADS)
Zhou, Jiang; D'Amore, Alberto; Yang, Yuming; He, Tianbai; Li, Binyao; Nicolais, Luigi
1994-05-01
Flexural fatigue tests were conducted on injection molded glass fiber reinforced a blend of polyphenylene ether ketone and polyphenylene sulfide composite using four-point bending with different stress ratios and different frequencies. The fatigue behavior of this material was described. The constructed S-N curves shift their trends obviously at the maximum cyclic stress being about 80% of the ultimate flexural strength. Examinations of failure surfaces for various loading conditions show that the fatigue failure mechanisms appear to be matrix yielding at high stresses and crack growth at low stresses. Analyses of the fatigue data at various stress ratios reveal that the data at low stress superimpose to form a single curve which is nearly linear when they are plotted as stress range versus number of cycles to failure in bilogarithmic axes, while the data at high stresses also converge to yield a single curve when they are plotted as ( S max S range)1/2 against specimen lifetimes ( S max is the maximum stress and S range is the stress range). These results show that for the studied material the main factor influencing the lifetime is the stress range at low stresses and the parameter ( S max S range)1/2 at high stresses. Comparison of fatigue data in the frequency range of 0.89 7.0 Hz was made, no significant effect of frequency on the fatigue behavior is found.
Compression fatigue behavior and failure mechanism of porous titanium for biomedical applications.
Li, Fuping; Li, Jinshan; Huang, Tingting; Kou, Hongchao; Zhou, Lian
2017-01-01
Porous titanium and its alloys are believed to be one of the most attractive biomaterials for orthopedic implant applications. In the present work, porous pure titanium with 50-70% porosity and different pore size was fabricated by diffusion bonding. Compression fatigue behavior was systematically studied along the out-of-plane direction. It resulted that porous pure titanium has anisotropic pore structure and the microstructure is fine-grained equiaxed α phase with a few twins in some α grains. Porosity and pore size have some effect on the S-N curve but this effect is negligible when the fatigue strength is normalized by the yield stress. The relationship between normalized fatigue strength and fatigue life conforms to a power law. The compression fatigue behavior is characteristic of strain accumulation. Porous titanium experiences uniform deformation throughout the entire sample when fatigue cycle is lower than a critical value (N T ). When fatigue cycles exceed N T , strain accumulates rapidly and a single collapse band forms with a certain angle to the loading direction, leading to the sudden failure of testing sample. Both cyclic ratcheting and fatigue crack growth contribute to the fatigue failure mechanism, while the cyclic ratcheting is the dominant one. Porous titanium possesses higher normalized fatigue strength which is in the range of 0.5-0.55 at 10 6 cycles. The reasons for the higher normalized fatigue strength were analyzed based on the microstructure and fatigue failure mechanism. Copyright © 2016 Elsevier Ltd. All rights reserved.
Accurate Prediction of Motor Failures by Application of Multi CBM Tools: A Case Study
NASA Astrophysics Data System (ADS)
Dutta, Rana; Singh, Veerendra Pratap; Dwivedi, Jai Prakash
2018-02-01
Motor failures are very difficult to predict accurately with a single condition-monitoring tool as both electrical and the mechanical systems are closely related. Electrical problem, like phase unbalance, stator winding insulation failures can, at times, lead to vibration problem and at the same time mechanical failures like bearing failure, leads to rotor eccentricity. In this case study of a 550 kW blower motor it has been shown that a rotor bar crack was detected by current signature analysis and vibration monitoring confirmed the same. In later months in a similar motor vibration monitoring predicted bearing failure and current signature analysis confirmed the same. In both the cases, after dismantling the motor, the predictions were found to be accurate. In this paper we will be discussing the accurate predictions of motor failures through use of multi condition monitoring tools with two case studies.
Noah, Moronke A; Ramachandra, Geethanjali; Hickey, Margaret M; Jenkins, David R; Harvey, Chris J; Westrope, Claire A; Firmin, Richard K; Peek, Giles J
2013-01-01
Legionella-associated respiratory failure has a high mortality, despite modern ventilation modalities. Extracorporeal membrane oxygenation (ECMO) is used to achieve gas exchange independent of pulmonary function in patients with severe respiratory failure. This was a retrospective review of the management and outcome of patients with Legionella-associated respiratory failure treated with ECMO support in a large ECMO center over the past 10 years. A retrospective review of patients with confirmed Legionella-associated severe respiratory failure managed with ECMO support at a single center. Between 2000 and 2010, 19 patients with severe respiratory failure caused by Legionella were managed with ECMO after failure to respond to conventional intensive care management. Median PaO2/FiO2 ratio was 66 and median pCO2 was 60 torr. Sixteen patients (84%) survived to hospital discharge. Extracorporeal membrane oxygenation should be considered in patients with Legionella-associated respiratory failure, who have failed conventional ventilation.
NASA Astrophysics Data System (ADS)
Taylor, Gabriel James
The failure of electrical cables exposed to severe thermal fire conditions are a safety concern for operating commercial nuclear power plants (NPPs). The Nuclear Regulatory Commission (NRC) has promoted the use of risk-informed and performance-based methods for fire protection which resulted in a need to develop realistic methods to quantify the risk of fire to NPP safety. Recent electrical cable testing has been conducted to provide empirical data on the failure modes and likelihood of fire-induced damage. This thesis evaluated numerous aspects of the data. Circuit characteristics affecting fire-induced electrical cable failure modes have been evaluated. In addition, thermal failure temperatures corresponding to cable functional failures have been evaluated to develop realistic single point thermal failure thresholds and probability distributions for specific cable insulation types. Finally, the data was used to evaluate the prediction capabilities of a one-dimension conductive heat transfer model used to predict cable failure.
SINGLE EVENT EFFECTS TEST FACILITY AT OAK RIDGE NATIONAL LABORATORY
DOE Office of Scientific and Technical Information (OSTI.GOV)
Riemer, Bernie; Gallmeier, Franz X; Dominik, Laura J
2015-01-01
Increasing use of microelectronics of ever diminishing feature size in avionics systems has led to a growing Single Event Effects (SEE) susceptibility arising from the highly ionizing interactions of cosmic rays and solar particles. Single event effects caused by atmospheric radiation have been recognized in recent years as a design issue for avionics equipment and systems. To ensure a system meets all its safety and reliability requirements, SEE induced upsets and potential system failures need to be considered, including testing of the components and systems in a neutron beam. Testing of ICs and systems for use in radiation environments requiresmore » the utilization of highly advanced laboratory facilities that can run evaluations on microcircuits for the effects of radiation. This paper provides a background of the atmospheric radiation phenomenon and the resulting single event effects, including single event upset (SEU) and latch up conditions. A study investigating requirements for future single event effect irradiation test facilities and developing options at the Spallation Neutron Source (SNS) is summarized. The relatively new SNS with its 1.0 GeV proton beam, typical operation of 5000 h per year, expertise in spallation neutron sources, user program infrastructure, and decades of useful life ahead is well suited for hosting a world-class SEE test facility in North America. Emphasis was put on testing of large avionics systems while still providing tunable high flux irradiation conditions for component tests. Makers of ground-based systems would also be served well by these facilities. Three options are described; the most capable, flexible, and highest-test-capacity option is a new stand-alone target station using about one kW of proton beam power on a gas-cooled tungsten target, with dual test enclosures. Less expensive options are also described.« less
Single Event Effects Test Facility Options at the Oak Ridge National Laboratory
DOE Office of Scientific and Technical Information (OSTI.GOV)
Riemer, Bernie; Gallmeier, Franz X; Dominik, Laura J
2015-01-01
Increasing use of microelectronics of ever diminishing feature size in avionics systems has led to a growing Single Event Effects (SEE) susceptibility arising from the highly ionizing interactions of cosmic rays and solar particles. Single event effects caused by atmospheric radiation have been recognized in recent years as a design issue for avionics equipment and systems. To ensure a system meets all its safety and reliability requirements, SEE induced upsets and potential system failures need to be considered, including testing of the components and systems in a neutron beam. Testing of integrated circuits (ICs) and systems for use in radiationmore » environments requires the utilization of highly advanced laboratory facilities that can run evaluations on microcircuits for the effects of radiation. This paper provides a background of the atmospheric radiation phenomenon and the resulting single event effects, including single event upset (SEU) and latch up conditions. A study investigating requirements for future single event effect irradiation test facilities and developing options at the Spallation Neutron Source (SNS) is summarized. The relatively new SNS with its 1.0 GeV proton beam, typical operation of 5000 h per year, expertise in spallation neutron sources, user program infrastructure, and decades of useful life ahead is well suited for hosting a world-class SEE test facility in North America. Emphasis was put on testing of large avionics systems while still providing tunable high flux irradiation conditions for component tests. Makers of ground-based systems would also be served well by these facilities. Three options are described; the most capable, flexible, and highest-test-capacity option is a new stand-alone target station using about one kW of proton beam power on a gas-cooled tungsten target, with dual test enclosures. Less expensive options are also described.« less
Wilson, D A; Keegan, K G; Carson, W L
1999-01-01
This study compared the mechanical properties of the normal intact suspensory apparatus and two methods of fixation for repair of transverse, midbody fractures of the proximal sesamoid bones of adult horses: transfixation wiring (TW) and screws placed in lag fashion (LS). An in vitro, paired study using equine cadaver limbs mounted in a loading apparatus was used to test the mechanical properties of TW and LS. Seventeen paired (13 repaired, 4 normal) equine cadaver limbs consisting of the suspensory apparatus third metacarpal bone, and first and second phalanges. The two methods of repair and normal intact specimens were evaluated in single cycle-to-failure loading. Yield failure was defined to occur at the first notable discontinuity (>50 N) in the load-displacement curve, the first visible failure as evident on the videotape, or a change in the slope of the moment-fetlock angle curve. Ultimate failure was defined to occur at the highest load resisted by the specimen. Corresponding resultant force and force per kg of body weight on the suspensory apparatus, fetlock joint moment, and angle of fetlock dorsiflexion were calculated by use of specimen dimensions and applied load. These were compared along with specimen stiffness, and ram displacement. Load on the suspensory apparatus, load on the suspensory apparatus per kg of body weight, moment, applied load, and angle of fetlock dorsiflexion at yield failure were significantly greater for the TW-repaired than for the LS-repaired specimens. A 3 to 5 mm gap was observed before yield failure in most TW-repaired osteotomies. Transfixation wiring provided greater strength to yield failure than screws placed in lag fashion in single cycle load-to-failure mechanical testing of repaired transverse osteotomized specimens of the medial proximal forelimb sesamoid bone.
A biomechanical comparison of single and double-row fixation in arthroscopic rotator cuff repair.
Smith, Christopher D; Alexander, Susan; Hill, Adam M; Huijsmans, Pol E; Bull, Anthony M J; Amis, Andrew A; De Beer, Joe F; Wallace, Andrew L
2006-11-01
The optimal method for arthroscopic rotator cuff repair is not yet known. The hypothesis of the present study was that a double-row repair would demonstrate superior static and cyclic mechanical behavior when compared with a single-row repair. The specific aims were to measure gap formation at the bone-tendon interface under static creep loading and the ultimate strength and mode of failure of both methods of repair under cyclic loading. A standardized tear of the supraspinatus tendon was created in sixteen fresh cadaveric shoulders. Arthroscopic rotator cuff repairs were performed with use of either a double-row technique (eight specimens) or a single-row technique (eight specimens) with nonabsorbable sutures that were double-loaded on a titanium suture anchor. The repairs were loaded statically for one hour, and the gap formation was measured. Cyclic loading to failure was then performed. Gap formation during static loading was significantly greater in the single-row group than in the double-row group (mean and standard deviation, 5.0 +/- 1.2 mm compared with 3.8 +/- 1.4 mm; p < 0.05). Under cyclic loading, the double-row repairs failed at a mean of 320 +/- 96.9 N whereas the single-row repairs failed at a mean of 224 +/- 147.9 N (p = 0.058). Three single-row repairs and three double-row repairs failed as a result of suture cut-through. Four single-row repairs and one double-row repair failed as a result of anchor or suture failure. The remaining five repairs did not fail, and a midsubstance tear of the tendon occurred. Although more technically demanding, the double-row technique demonstrates superior resistance to gap formation under static loading as compared with the single-row technique. A double-row reconstruction of the supraspinatus tendon insertion may provide a more reliable construct than a single-row repair and could be used as an alternative to open reconstruction for the treatment of isolated tears.
Sanyal, Arnav; Keaveny, Tony M.
2013-01-01
The biaxial failure behavior of the human trabecular bone, which has potential relevance both for fall and gait loading conditions, is not well understood, particularly for low-density bone, which can display considerable mechanical anisotropy. Addressing this issue, we investigated the biaxial normal strength behavior and the underlying failure mechanisms for human trabecular bone displaying a wide range of bone volume fraction (0.06–0.34) and elastic anisotropy. Micro-computer tomography (CT)-based nonlinear finite element analysis was used to simulate biaxial failure in 15 specimens (5 mm cubes), spanning the complete biaxial normal stress failure space in the axial-transverse plane. The specimens, treated as approximately transversely isotropic, were loaded in the principal material orientation. We found that the biaxial stress yield surface was well characterized by the superposition of two ellipses—one each for yield failure in the longitudinal and transverse loading directions—and the size, shape, and orientation of which depended on bone volume fraction and elastic anisotropy. However, when normalized by the uniaxial tensile and compressive strengths in the longitudinal and transverse directions, all of which depended on bone volume fraction, microarchitecture, and mechanical anisotropy, the resulting normalized biaxial strength behavior was well described by a single pair of (longitudinal and transverse) ellipses, with little interspecimen variation. Taken together, these results indicate that the role of bone volume fraction, microarchitecture, and mechanical anisotropy is mostly accounted for in determining the uniaxial strength behavior and the effect of these parameters on the axial-transverse biaxial normal strength behavior per se is minor. PMID:24121715
Silencing the Patient: Freud, Sexual Abuse, and "The Etiology of Hysteria."
ERIC Educational Resources Information Center
McOmber, James B.
1996-01-01
States that, in "The Etiology of Hysteria," Sigmund Freud's "seduction theory" asserted that child sexual abuse was the single cause of adult hysteria. Argues that Freud's failure to persuade his audience can be attributed not only to their denial of sexual abuse but also to his failure to clarify how pschyoanalysis could…
30 CFR 18.68 - Tests for intrinsic safety.
Code of Federal Regulations, 2012 CFR
2012-07-01
... requirements may be added at any time if features of construction or use or both indicate them to be necessary.... They shall be designed to withstand a test voltage of 1,500 volts. (4) Intrinsically safe circuits shall be so designed that after failure of a single component, and subsequent failures resulting from...
30 CFR 18.68 - Tests for intrinsic safety.
Code of Federal Regulations, 2011 CFR
2011-07-01
... requirements may be added at any time if features of construction or use or both indicate them to be necessary.... They shall be designed to withstand a test voltage of 1,500 volts. (4) Intrinsically safe circuits shall be so designed that after failure of a single component, and subsequent failures resulting from...
30 CFR 18.68 - Tests for intrinsic safety.
Code of Federal Regulations, 2010 CFR
2010-07-01
... requirements may be added at any time if features of construction or use or both indicate them to be necessary.... They shall be designed to withstand a test voltage of 1,500 volts. (4) Intrinsically safe circuits shall be so designed that after failure of a single component, and subsequent failures resulting from...
30 CFR 18.68 - Tests for intrinsic safety.
Code of Federal Regulations, 2013 CFR
2013-07-01
... requirements may be added at any time if features of construction or use or both indicate them to be necessary.... They shall be designed to withstand a test voltage of 1,500 volts. (4) Intrinsically safe circuits shall be so designed that after failure of a single component, and subsequent failures resulting from...
49 CFR 571.105 - Standard No. 105; Hydraulic and electric brake systems.
Code of Federal Regulations, 2014 CFR
2014-10-01
... current, and which may include a non-electrical source of power designed to charge batteries and... dissipating electrical energy. Skid number means the frictional resistance of a pavement measured in..., designed so that a single failure in any subsystem (such as a leakage-type failure of a pressure component...
49 CFR 571.105 - Standard No. 105; Hydraulic and electric brake systems.
Code of Federal Regulations, 2012 CFR
2012-10-01
... current, and which may include a non-electrical source of power designed to charge batteries and... dissipating electrical energy. Skid number means the frictional resistance of a pavement measured in..., designed so that a single failure in any subsystem (such as a leakage-type failure of a pressure component...
49 CFR 571.105 - Standard No. 105; Hydraulic and electric brake systems.
Code of Federal Regulations, 2013 CFR
2013-10-01
... current, and which may include a non-electrical source of power designed to charge batteries and... dissipating electrical energy. Skid number means the frictional resistance of a pavement measured in..., designed so that a single failure in any subsystem (such as a leakage-type failure of a pressure component...
14 CFR 25.809 - Emergency exit arrangement.
Code of Federal Regulations, 2013 CFR
2013-01-01
...-boost or single power-operated system is the primary system for operating more than one exit in an... effort; and must be arranged and marked so that it can be readily located and operated, even in darkness... event of failure of the primary system. Manual operation of the exit (after failure of the primary...
14 CFR 25.809 - Emergency exit arrangement.
Code of Federal Regulations, 2012 CFR
2012-01-01
...-boost or single power-operated system is the primary system for operating more than one exit in an... effort; and must be arranged and marked so that it can be readily located and operated, even in darkness... event of failure of the primary system. Manual operation of the exit (after failure of the primary...
14 CFR 25.809 - Emergency exit arrangement.
Code of Federal Regulations, 2010 CFR
2010-01-01
...-boost or single power-operated system is the primary system for operating more than one exit in an... effort; and must be arranged and marked so that it can be readily located and operated, even in darkness... event of failure of the primary system. Manual operation of the exit (after failure of the primary...
14 CFR 25.809 - Emergency exit arrangement.
Code of Federal Regulations, 2014 CFR
2014-01-01
...-boost or single power-operated system is the primary system for operating more than one exit in an... effort; and must be arranged and marked so that it can be readily located and operated, even in darkness... event of failure of the primary system. Manual operation of the exit (after failure of the primary...
Cohesive Modeling of Transverse Cracking in Laminates with a Single Layer of Elements per Ply
NASA Technical Reports Server (NTRS)
VanDerMeer, Frans P.; Davila, Carlos G.
2013-01-01
This study aims to bridge the gap between classical understanding of transverse cracking in cross-ply laminates and recent computational methods for the modeling of progressive laminate failure. Specifically, the study investigates under what conditions a finite element model with cohesive X-FEM cracks can reproduce the in situ effect for the ply strength. It is shown that it is possible to do so with a single element across the thickness of the ply, provided that the interface stiffness is properly selected. The optimal value for this interface stiffness is derived with an analytical shear lag model. It is also shown that, when the appropriate statistical variation of properties has been applied, models with a single element through the thickness of a ply can predict the density of transverse matrix cracks
Icodextrin and peritoneal dialysis: advantages and new applications.
Dousdampanis, Periklis; Musso, Carlos Guido; Trigka, Konstantina
2018-03-01
The impact of icodextrin (ico) on peritoneal dialysis (PD) extension and patient survival is well established. Predominantly, ico-based solutions were prescribed in high-transporter PD patients. Advantages of the ico-based solutions include increased biocompatibility, avoidance of glucotoxicity, enhanced ultrafiltration failure (UF), sodium removal rates, better metabolic and blood pressure control. Bimodal solutions and twice daily exchanges of ico-based solutions are two newly introduced strategies to avoid glucose exposure and/or enhance UF in PD patients with UF failure. In addition, a simplified schedule of PD using a single nocturnal exchange of ico in patients with refractory congestive heart failure may represent an alternative option to manage fluid removal and azotaemia. The use of a simplified schedule of PD with only two ico exchanges or a single ico exchange is a challenging approach for end-stage renal disease patients with preserved residual function who desire to initiate PD.
Pre-configured polyhedron based protection against multi-link failures in optical mesh networks.
Huang, Shanguo; Guo, Bingli; Li, Xin; Zhang, Jie; Zhao, Yongli; Gu, Wanyi
2014-02-10
This paper focuses on random multi-link failures protection in optical mesh networks, instead of single, the dual or sequential failures of previous studies. Spare resource efficiency and failure robustness are major concerns in link protection strategy designing and a k-regular and k-edge connected structure is proved to be one of the optimal solutions for link protection network. Based on this, a novel pre-configured polyhedron based protection structure is proposed, and it could provide protection for both simultaneous and sequential random link failures with improved spare resource efficiency. Its performance is evaluated in terms of spare resource consumption, recovery rate and average recovery path length, as well as compared with ring based and subgraph protection under probabilistic link failure scenarios. Results show the proposed novel link protection approach has better performance than previous works.
The discovery of the pressor effect of DOPS and its blunting by decarboxylase inhibitors.
Kaufmann, H
2006-01-01
In the 1950s it was found that an artificial aminoacid, 3,4-threo-dihydroxyphenylserine (DOPS), was converted to norepinephrine (NE) in a single step by the enzyme L-aromatic amino acid decarboxylase (AADC), bypassing the need for the rate limiting enzyme dopamine beta hydroxylase. Trying to replicate the success of dihydroxyphenylalanine (DOPA) in the treatment of Parkinson disease, treatment with DOPS was attempted in patients with autonomic failure who have impaired NE release. DOPS improved orthostatic hypotension in patients with familial amyloid polyneuropathy, congenital deficiency of dopamine beta hydroxylase, pure autonomic failure and multiple system atrophy. DOPS pressor effect is due to its conversion to NE outside the central nervous system because concomitant administration of carbidopa, an inhibitor of AADC that does not cross the blood-brain barrier, blunted both the increase in plasma NE and the pressor response. DOPS pressor response is not dependent on intact sympathetic terminals because its conversion to NE also occurs in non-neuronal tissues.
Elashoff, Robert M.; Li, Gang; Li, Ning
2009-01-01
Summary In this article we study a joint model for longitudinal measurements and competing risks survival data. Our joint model provides a flexible approach to handle possible nonignorable missing data in the longitudinal measurements due to dropout. It is also an extension of previous joint models with a single failure type, offering a possible way to model informatively censored events as a competing risk. Our model consists of a linear mixed effects submodel for the longitudinal outcome and a proportional cause-specific hazards frailty submodel (Prentice et al., 1978, Biometrics 34, 541-554) for the competing risks survival data, linked together by some latent random effects. We propose to obtain the maximum likelihood estimates of the parameters by an expectation maximization (EM) algorithm and estimate their standard errors using a profile likelihood method. The developed method works well in our simulation studies and is applied to a clinical trial for the scleroderma lung disease. PMID:18162112
Sod, Gary A; Mitchell, Colin F; Hubert, Jeremy D; Martin, George S; Gill, Marjorie S
2007-12-01
To compare in vitro monotonic biomechanical properties of an equine spoon plate (ESP) with an axial 3-hole, 4.5 mm narrow dynamic compression plate (DCP) using 5.5 mm cortical screws in conjunction with 2 abaxial transarticular 5.5 mm cortical screws (DCP-TLS) inserted in lag fashion for equine proximal interphalangeal (PIP) joint arthrodesis. Paired in vitro biomechanical testing of 2 methods of stabilizing cadaveric adult equine forelimb PIP joints. Cadaveric adult equine forelimbs (n=18 pairs). For each forelimb pair, 1 PIP joint was stabilized with an ESP (8 hole, 4.5 mm) and 1 with an axial 3-hole narrow DCP (4.5 mm) using 5.5 mm cortical screws in conjunction with 2 abaxial transarticular 5.5 mm cortical screws inserted in lag fashion. Six matching pairs of constructs were tested in single cycle to failure under axial compression with load applied under displacement control at a constant rate of 5 cm/s. Six construct pairs were tested for cyclic fatigue under axial compression with cyclic load (0-7.5 kN) applied at 6 Hz; cycles to failure were recorded. Six construct pairs were tested in single cycle to failure under torsional loading applied at a constant displacement rate (0.17 radians/s) until rotation of 0.87 radians occurred. Mean values for each fixation method were compared using a paired t-test within each group with statistical significance set at P<.05. Mean yield load, yield stiffness, and failure load for ESP fixation were significantly greater (for axial compression and torsion) than for DCP-TLS fixation. Mean (+/- SD) values for the ESP and DCP-TLS fixation techniques, respectively, in single cycle to failure under axial compression were: yield load 123.9 +/- 8.96 and 28.5 +/- 3.32 kN; stiffness, 13.11 +/- 0.242 and 2.60 +/- 0.17 kN/cm; and failure load, 144.4 +/- 13.6 and 31.4 +/- 3.8 kN. In single cycle to failure under torsion, mean (+/- SD) values for ESP and DCP-TLS, respectively, were: stiffness 2,022 +/- 26.2 and 107.9 +/- 11.1 N m/rad; and failure load: 256.4 +/- 39.2 and 87.1 +/- 11.5 N m. Mean cycles to failure in axial compression of ESP fixation (622,529 +/- 65,468) was significantly greater than DCP-TLS (95,418 +/- 11,037). ESP was superior to an axial 3-hole narrow DCP with 2 abaxial transarticular screws inserted in lag fashion in resisting static overload forces and cyclic fatigue. In vitro results support further evaluation of ESP for PIP joint arthrodesis in horses. Its specific design may provide increased stability without need for external coaptation support.
Delamination and Stitched Failure in Stitched Composite Joints
NASA Technical Reports Server (NTRS)
Glaessgen, E. H.; Raju, I. S.; Poe, C. C., Jr.
1999-01-01
The effect of stitches on the failure of a single lap joint configuration was determined in a combined experimental and finite element study. The experimental program was conducted to determine debond growth under static monotonic loading. The stitches were shown to delay the initiation of the debond and provide load transfer beyond the load necessary to completely debond the stitched lap joint. The experimentally determined debond length vs. applied load was used as an input parameter in the finite element analysis of both configurations. The strain energy release rates at the debond from were calculated using plate finite elements. Nonlinear fastener elements were used to model the stitches and multipoint constraints were used to model the contact problem. Models of the unstitched configuration showed significant values of modes I and II across the width of the joint and showed that mode III is zero at the centerline but increases near the free edge. Models of the stitched configuration showed that the stitches were effective in reducing mode I to zero, but had less of an effect on modes II and III.
Okuhara, Yoshitaka; Hirotani, Shinichi; Ando, Tomotaka; Nishimura, Koichi; Orihara, Yoshiyuki; Komamura, Kazuo; Naito, Yoshiro; Mano, Toshiaki; Masuyama, Tohru
2017-04-01
Hypertonic saline with furosemide has been proposed for a long time as an effective therapeutic option for the treatment of acute decompensated heart failure (ADHF). We previously reported the efficacy of continuous infusion of 1.7 % hypertonic saline plus low-dose furosemide in treatment for ADHF. Although this therapeutic strategy can be a useful option for effective decongestion in treatment for ADHF, there is no study that assesses the effect and safety of saline supplementation compared with standard therapy in Japan. The aim of this study was to investigate the efficacy, safety, and cost-effectiveness of 1.7 % hypertonic saline plus low-dose furosemide infusion compared with carperitide. We compared clinical outcomes, adverse events, and cost for patients receiving carperitide (carperitide group) with those for patients receiving 1.7 % hypertonic saline plus low-dose furosemide (salt group) during the initial hospitalization for ADHF. The cost analysis was performed on the basis of the previous report about cost-effectiveness of acute heart failure. A total of 175 ADHF patients received either carperitide (n = 111) or 1.7 % hypertonic saline plus low-dose furosemide infusion (n = 64) as initial treatment. There were no differences in length of hospital stay (27 ± 19 vs. 25 ± 16 day, p = 0.170) and infusion period (7.2 ± 6.1 vs. 8.4 ± 7.5 day, p = 0.474) between the two groups. The incidence of rehospitalization did not differ at 1 month (7.6 vs. 6.6 %, p = 1.000) and 1 year (36.8 vs. 37.7 %, p = 0.907) between the two groups. The Kaplan-Meier curves revealed no significant difference for 1 year all-cause mortality between the two groups (log-rank, p = 0.724). The single hospitalization cost was 95,314 yen lower and the yearly hospitalization cost 125,628 yen lower in the salt group compared with the carperitide group. Thus, intravenous 1.7 % hypertonic saline plus low-dose furosemide infusion is as effective as carperitide in terms of clinical outcome and is a cost-effective therapeutic strategy for the treatment of ADHF.
Grady, Kathleen L.; Mendes de Leon, Carlos F.; Kozak, Andrea T.; Cursio, John F.; Richardson, DeJuran; Avery, Elizabeth; Calvin, James E.; Powell, Lynda H.
2013-01-01
Purpose Heart failure (HF) is associated with poor health-related quality of life (HRQOL). The purpose of our study is to determine the effect of a self-management intervention on HRQOL domains across time, overall and in pre-specified demographic, clinical, and psychosocial subgroups of HF patients. Methods HART was a single-center, multi-hospital randomized trial. Patients (n=902) were randomized either to a self-management intervention with provision of HF educational information or an enhanced education control group which received the same HF educational materials. HRQOL was measured by the Quality of Life Index, Cardiac Version, modified and the Medical Outcomes Study 36-item Short-Form Health Survey physical functioning scale. Analyses included descriptive statistics and mixed-effects regression models. Results In general, overall, study participants’ HRQOL improved over time. However, no significant differences in HRQOL domain were detected between treatment groups at baseline or across time (p>0.05). Subgroup analyses demonstrated no differences by treatment arm for change in HRQOL from baseline to 3 years later. Conclusions We conclude that in our cohort of patients, the self-management intervention had no benefit over enhanced education in improving domains of HRQOL and HRQOL for specified HF subgroups. PMID:23743855
[Comparative study of three bonding methods in attaching removable thermoplastic appliances].
Chu, Kejia; Wang, Haihui; Zheng, Zhijun; Li, Qi
2015-10-01
To evaluate the operation time and clinical effect of three types of materials (i.e., total-etching adhesive, self-etching adhesive, resin-modified glass ionomer cement) that are used to bond removable thermoplastic appliances. Thirty malocclusion patients (156 attachments) with removable thermoplastic appliances were randomly divided into three groups, with 10 individuals each. Attachments of groups A and B were bonded using 3M Adper Single Bond 2 and 3M Adper Easy One, respectively; both adhesives utilized 3M Z350 nano composite resin. Attachments of group C was directly bonded using GC Fuji Ortho LC. The operation time of each attachment was recorded. Failure rates of adhesion were evaluated during adhesion, 1 month after treatment, and 6 months after treatment. The operation time of group C was shorter than those of groups A and B (P<0.01). Significant difference of adhesion failure rates was not found among the three groups (P>0.05). No significant difference of adhesion failure rates was also observed in different times of the same group (P>0.05). The attachment stability of the three types of materials achieved satisfactory effects. However, the operation method of resin-modified glass ionomer cement is more concise and suitable for clinical promotion.
NASA Astrophysics Data System (ADS)
Sayyidmousavi, Alireza; Bougherara, Habiba; Fawaz, Zouheir
2015-06-01
A micromechanical approach is adopted to study the role of viscoelasticity on the fatigue behavior of polymer matrix composites. In particular, the study examines the interaction of fatigue and creep in angle ply carbon/epoxy at 25 and 114 °C. The matrix phase is modeled as a vicoelastic material using Schapery's single integral constitutive equation. Taking viscoelsticity into account allows the study of creep strain evolution during the fatigue loading. The fatigue failure criterion is expressed in terms of the fatigue failure functions of the constituent materials. The micromechanical model is also used to calculate these fatigue failure functions from the knowledge of the S-N diagrams of the composite material in longitudinal, transverse and shear loadings thus eliminating the need for any further experimentation. Unlike the previous works, the present study can distinguish between the strain evolution due to fatigue and creep. The results can clearly show the contribution made by the effect of viscoelasticity to the total strain evolution during the fatigue life of the specimen. Although the effect of viscoelsticity is found to increase with temperature, its contribution to strain development during fatigue is compromised by the shorter life of the specimen when compared to lower temperatures.
NASA Technical Reports Server (NTRS)
Liu, Kuang C.; Arnold, Steven M.
2011-01-01
It is well known that failure of a material is a locally driven event. In the case of ceramic matrix composites (CMCs), significant variations in the microstructure of the composite exist and their significance on both deformation and life response need to be assessed. Examples of these variations include changes in the fiber tow shape, tow shifting/nesting and voids within and between tows. In the present work, the effects of many of these architectural parameters and material scatter of woven ceramic composite properties at the macroscale (woven RUC) will be studied to assess their sensitivity. The recently developed Multiscale Generalized Method of Cells methodology is used to determine the overall deformation response, proportional elastic limit (first matrix cracking), and failure under tensile loading conditions. The macroscale responses investigated illustrate the effect of architectural and material parameters on a single RUC representing a five harness satin weave fabric. Results shows that the most critical architectural parameter is weave void shape and content with other parameters being less in severity. Variation of the matrix material properties was also studied to illustrate the influence of the material variability on the overall features of the composite stress-strain response.
Modeling Grade IV Gas Emboli using a Limited Failure Population Model with Random Effects
NASA Technical Reports Server (NTRS)
Thompson, Laura A.; Conkin, Johnny; Chhikara, Raj S.; Powell, Michael R.
2002-01-01
Venous gas emboli (VGE) (gas bubbles in venous blood) are associated with an increased risk of decompression sickness (DCS) in hypobaric environments. A high grade of VGE can be a precursor to serious DCS. In this paper, we model time to Grade IV VGE considering a subset of individuals assumed to be immune from experiencing VGE. Our data contain monitoring test results from subjects undergoing up to 13 denitrogenation test procedures prior to exposure to a hypobaric environment. The onset time of Grade IV VGE is recorded as contained within certain time intervals. We fit a parametric (lognormal) mixture survival model to the interval-and right-censored data to account for the possibility of a subset of "cured" individuals who are immune to the event. Our model contains random subject effects to account for correlations between repeated measurements on a single individual. Model assessments and cross-validation indicate that this limited failure population mixture model is an improvement over a model that does not account for the potential of a fraction of cured individuals. We also evaluated some alternative mixture models. Predictions from the best fitted mixture model indicate that the actual process is reasonably approximated by a limited failure population model.
Fungal Infections: The Stubborn Cases
Adam, John E.
1982-01-01
Despite development of numerous antifungal preparations, mycotic infections persist, because of inaccurate diagnosis leading to inappropriate therapy, drug failure, non-compliance or resistance of the organism to antifungal medication. Direct KOH examination is the simplest method of proving the existence of a fungus. Fungal infections tend to be overdiagnosed; disorders which do not improve with three to four weeks of treatment should be reassessed before being labelled ‘stubborn’. Griseofulvin is effective treatment for all dermatophytes, but has certain side effects. Newer topical antifungals are also effective, but no single drug cures all fungal infections. ImagesFig. 1Fig. 2Fig. 3Fig. 4Fig. 5Fig. 6Fig. 7Fig. 8 PMID:20469387
Updated hazard rate equations for dual safeguard systems.
Rothschild, Marc
2007-04-11
A previous paper by this author [M.J. Rothschild, Updated hazard rate equation for single safeguards, J. Hazard. Mater. 130 (1-2) (2006) 15-20] showed that commonly used analytical methods for quantifying failure rates overestimates the risk in some circumstances. This can lead the analyst to mistakenly believe that a given operation presents an unacceptable risk. For a single safeguard system, a formula was presented in that paper that accurately evaluates the risk over a wide range of conditions. This paper expands on that analysis by evaluating the failure rate for dual safeguard systems. The safeguards can be activated at the same time or at staggered times, and the safeguard may provide an indication whether it was successful upon a challenge, or its status may go undetected. These combinations were evaluated using a Monte Carlo simulation. Empirical formulas for evaluating the hazard rate were developed from this analysis. It is shown that having the safeguards activate at the same time while providing positive feedback of their individual actions is the most effective arrangement in reducing the hazard rate. The hazard rate can also be reduced by staggering the testing schedules of the safeguards.
Rate-weakening friction characterizes both slow sliding and catastrophic failure of landslides
NASA Astrophysics Data System (ADS)
Handwerger, Alexander L.; Rempel, Alan W.; Skarbek, Rob M.; Roering, Joshua J.; Hilley, George E.
2016-09-01
Catastrophic landslides cause billions of dollars in damages and claim thousands of lives annually, whereas slow-moving landslides with negligible inertia dominate sediment transport on many weathered hillslopes. Surprisingly, both failure modes are displayed by nearby landslides (and individual landslides in different years) subjected to almost identical environmental conditions. Such observations have motivated the search for mechanisms that can cause slow-moving landslides to transition via runaway acceleration to catastrophic failure. A similarly diverse range of sliding behavior, including earthquakes and slow-slip events, occurs along tectonic faults. Our understanding of these phenomena has benefitted from mechanical treatments that rely upon key ingredients that are notably absent from previous landslide descriptions. Here, we describe landslide motion using a rate- and state-dependent frictional model that incorporates a nonlocal stress balance to account for the elastic response to gradients in slip. Our idealized, one-dimensional model reproduces both the displacement patterns observed in slow-moving landslides and the acceleration toward failure exhibited by catastrophic events. Catastrophic failure occurs only when the slip surface is characterized by rate-weakening friction and its lateral dimensions exceed a critical nucleation length
Przekora, Agata; Zarnowski, Tomasz; Ginalska, Grazyna
2017-01-01
Human Tenon's fibroblasts (HTFs) play a crucial role in wound healing. They cause postoperative scarring of the filtering bleb and are thus responsible for trabeculectomy failure. This study aimed to find an effective and fast protocol for HTF isolation from trabeculectomy biopsies. The protocol was compared with the commonly recommended HTF isolation procedure, which uses Dulbecco's modified Eagle's medium (DMEM). We used Eagle's minimum essential medium (EMEM) enriched with fibroblast growth factor (FGF), which selectively promoted the proliferation of HTF cells. A secondary goal was to compare HTF morphology, metabolism and growth during parallel cultivation of the isolated cells in FGF-enriched EMEM and DMEM. Standard procedures for HTF isolation from tissue biopsies require a 20- to 30-day culture of the explants to obtain the first monolayer. Our protocol yielded the first monolayer after approx. 15 days. More importantly, the majority of the cells were fibroblasts with only individual epithelium-derived cells present. Using FGF-enriched EMEM allowed 1.3 × 10 6 vimentin-positive fibroblasts to be obtained from a single biopsy within approx. 25 days. Using DMEM resulted in isolation failure and required exchange to FGF-enriched medium to recover the fibroblast culture. HTFs maintained in FGF-enriched EMEM also showed faster proliferation and a different type I collagen production ability compared to HTFs cultured in DMEM. Thus, FGF-enriched EMEM is recommended for fast propagation of HTFs unless the aim of the study is to assess the effect of a tested agent on proliferation ability or type I collagen production. Our fast protocol for HTF isolation allows easy setup of cell banks by researchers under laboratory conditions and could be very useful during testing of novel ophthalmologic anti-fibrotic agents in vitro. Molecular analysis of HTFs isolated from patients with known treatment histories may provide valuable information on the effects of some medications taken before glaucoma surgery on the subsequent wound-healing process and potential for trabeculectomy failure.
NASA Technical Reports Server (NTRS)
Ly, U. L.; Ho, J. K.
1986-01-01
A systematic procedure for the synthesis of fault tolerant control laws to actuator failure has been presented. Two design methods were used to synthesize fault tolerant controllers: the conventional LQ design method and a direct feedback controller design method SANDY. The latter method is used primarily to streamline the full-state Q feedback design into a practical implementable output feedback controller structure. To achieve robustness to control actuator failure, the redundant surfaces are properly balanced according to their control effectiveness. A simple gain schedule based on the landing gear up/down logic involving only three gains was developed to handle three design flight conditions: Mach .25 and Mach .60 at 5000 ft and Mach .90 at 20,000 ft. The fault tolerant control law developed in this study provides good stability augmentation and performance for the relaxed static stability aircraft. The augmented aircraft responses are found to be invariant to the presence of a failure. Furthermore, single-loop stability margins of +6 dB in gain and +30 deg in phase were achieved along with -40 dB/decade rolloff at high frequency.
Stress Transmission and Failure in Disordered Porous Media
NASA Astrophysics Data System (ADS)
Laubie, Hadrien; Radjai, Farhang; Pellenq, Roland; Ulm, Franz-Josef
2017-08-01
By means of extensive lattice-element simulations, we investigate stress transmission and its relation with failure properties in increasingly disordered porous systems. We observe a non-Gaussian broadening of stress probability density functions under tensile loading with increasing porosity and disorder, revealing a gradual transition from a state governed by single-pore stress concentration to a state controlled by multipore interactions and metric disorder. This effect is captured by the excess kurtosis of stress distributions and shown to be nicely correlated with the second moment of local porosity fluctuations, which appears thus as a (dis)order parameter for the system. By generating statistical ensembles of porous textures with varying porosity and disorder, we derive a general expression for the fracture stress as a decreasing function of porosity and disorder. Focusing on critical sites where the local stress is above the global fracture threshold, we also analyze the transition to failure in terms of a coarse-graining length. These findings provide a general framework which can also be more generally applied to multiphase and structural heterogeneous materials.
Chang, De-Hua; Mammadov, Kamal; Hickethier, Tilman; Borggrefe, Jan; Hellmich, Martin; Maintz, David; Kabbasch, Christoph
2017-01-01
Evaluation of the efficacy of single-shot, low-dose urokinase administration for the treatment of port catheter-associated fibrin sheaths. Forty-six patients were retrospectively evaluated for 54 episodes of port catheter dysfunction. The presence of a fibrin sheath was detected by angiographic contrast examinations. On an outpatient basis, patients subsequently received thrombolysis consisting of a single injection of urokinase (15.000 IU in 1.5 mL normal saline) through the port system. A second attempt was made in cases of treatment failure. Patients were followed up for technical success, complications and long-term outcome. Port dysfunction occurred at a median of 117 days after implantation (range: 7-825 days). The technical success after first port dysfunction by thrombolysis was 87% (40/46); thereof, initial thrombolysis was effective in 78% (36/46). Nine patients (20%) received a second dose of urokinase after previous treatment failure. Follow-up was available for 26 of 40 patients after successful thrombolysis. In 8 of these, rethrombosis occurred after a median of 98 days (range: 21-354 days), whereby rethrombolysis was effective in 5 of 7 (63%) patients. The overall success of all thrombolyses performed was 70% (45/64). No procedure-related technical or clinical complications occurred. After first favorable thrombolysis, a Kaplan-Meier analysis yielded a 30-, 90- and 180-day probability of patency of 96%, 87% and 81%. Thrombolytic therapy on an outpatient basis appears to be a safe and efficient. Three-month patency rates are comparable to more invasive treatment options, including catheter exchange over a guide wire and percutaneous fibrin sheath stripping.
Chang, De-Hua; Mammadov, Kamal; Hickethier, Tilman; Borggrefe, Jan; Hellmich, Martin; Maintz, David; Kabbasch, Christoph
2017-01-01
Purpose Evaluation of the efficacy of single-shot, low-dose urokinase administration for the treatment of port catheter-associated fibrin sheaths. Methods Forty-six patients were retrospectively evaluated for 54 episodes of port catheter dysfunction. The presence of a fibrin sheath was detected by angiographic contrast examinations. On an outpatient basis, patients subsequently received thrombolysis consisting of a single injection of urokinase (15.000 IU in 1.5 mL normal saline) through the port system. A second attempt was made in cases of treatment failure. Patients were followed up for technical success, complications and long-term outcome. Results Port dysfunction occurred at a median of 117 days after implantation (range: 7–825 days). The technical success after first port dysfunction by thrombolysis was 87% (40/46); thereof, initial thrombolysis was effective in 78% (36/46). Nine patients (20%) received a second dose of urokinase after previous treatment failure. Follow-up was available for 26 of 40 patients after successful thrombolysis. In 8 of these, rethrombosis occurred after a median of 98 days (range: 21–354 days), whereby rethrombolysis was effective in 5 of 7 (63%) patients. The overall success of all thrombolyses performed was 70% (45/64). No procedure-related technical or clinical complications occurred. After first favorable thrombolysis, a Kaplan–Meier analysis yielded a 30-, 90- and 180-day probability of patency of 96%, 87% and 81%. Conclusion Thrombolytic therapy on an outpatient basis appears to be a safe and efficient. Three-month patency rates are comparable to more invasive treatment options, including catheter exchange over a guide wire and percutaneous fibrin sheath stripping. PMID:28182117
Elvik, Rune
2011-11-01
A large number of studies have tried to assess how various aspects of driver health influence driver involvement in accidents. The objective of this paper is to provide a framework for a critical assessment of the quality these studies from a methodological point of view. Examples are given of how various sources of bias and confounding can produce study findings that are highly misleading. Ten potential sources of error and bias in epidemiological studies of the contribution of driver health impairments to road accidents are discussed: (1) Poor description of the medical conditions whose effects are studied (measurement error). (2) Inadequate control for the effects of exposure on accident rate. (3) Sampling endogeneity with respect to assessment for fitness to drive (outcome-based sampling; self-selection bias). (4) Combined exposure to several risk factors. (5) Poor control for potentially confounding factors. (6) Failure to specify potentially moderating factors (interaction effects). (7) Failure to consider a severity gradient with respect to the effect of health impairments. (8) Failure to specify the compliance of drivers with medical treatments or treatment effectiveness. (9) No data on the population prevalence of various health conditions. (10) The use of multiple study approaches and methods making the comparison and synthesis of findings difficult. Examples are given of how all these items may influence the findings of a single study or make synthesising findings from multiple studies difficult. A checklist for assessing study quality is provided. Copyright © 2011 Elsevier Ltd. All rights reserved.
Single-Lap-Joint Screening of Hysol EA 9309NA Epoxy Adhesive
2017-05-01
1 Fig. 2 Load vs. displacement for RT (no conditioning) samples .................... 6 Fig. 3...Load vs. displacement for RT (hot/wet conditioning) samples ............ 7 Fig. 5 Failure surface for RT (hot/wet conditioning) samples. MSAT ID...20140469, mode of failure = adhesive. ................................................. 8 Fig. 6 Load vs. displacement for ET samples (66 °C postcure
Patient-Specific Modeling of Interventricular Hemodynamics in Single Ventricle Physiology
NASA Astrophysics Data System (ADS)
Vedula, Vijay; Feinstein, Jeffrey; Marsden, Alison
2016-11-01
Single ventricle (SV) congenital heart defects, in which babies are born with only functional ventricle, lead to significant morbidity and mortality with over 30% of patients developing heart failure prior to adulthood. Newborns with SV physiology typically undergo three palliative surgeries, in which the SV becomes the systemic pumping chamber. Depending on which ventricle performs the systemic function, patients are classified as having either a single left ventricle (SLV) or a single right ventricle (SRV), with SRV patients at higher risk of failure. As the native right ventricles are not designed to meet systemic demands, they undergo remodeling leading to abnormal hemodynamics. The hemodynamic characteristics of SLVs compared with SRVs is not well established. We present a validated computational framework for performing patient-specific modeling of ventricular flows, and apply it across 6 SV patients (3SLV + 3SRV), comparing hemodynamic conditions between the two subgroups. Simulations are performed with a stabilized finite element method coupled with an immersed boundary method for modeling heart valves. We discuss identification of hemodynamic biomarkers of ventricular remodeling for early risk assessment of failure. This research is supported in part by the Stanford Child Health Research Institute and the Stanford NIH-NCATS-CTSA through Grant UL1 TR001085 and due to U.S. National Institute of Health through NIH NHLBI R01 Grants 5R01HL129727-02 and 5R01HL121754-03.
Seto, Emily; Leonard, Kevin J; Cafazzo, Joseph A; Barnsley, Jan; Masino, Caterina; Ross, Heather J
2012-02-10
Previous trials of heart failure telemonitoring systems have produced inconsistent findings, largely due to diverse interventions and study designs. The objectives of this study are (1) to provide in-depth insight into the effects of telemonitoring on self-care and clinical management, and (2) to determine the features that enable successful heart failure telemonitoring. Semi-structured interviews were conducted with 22 heart failure patients attending a heart function clinic who had used a mobile phone-based telemonitoring system for 6 months. The telemonitoring system required the patients to take daily weight and blood pressure readings, weekly single-lead ECGs, and to answer daily symptom questions on a mobile phone. Instructions were sent to the patient's mobile phone based on their physiological values. Alerts were also sent to a cardiologist's mobile phone, as required. All clinicians involved in the study were also interviewed post-trial (N = 5). The interviews were recorded, transcribed, and then analyzed using a conventional content analysis approach. The telemonitoring system improved patient self-care by instructing the patients in real-time how to appropriately modify their lifestyle behaviors. Patients felt more aware of their heart failure condition, less anxiety, and more empowered. Many were willing to partially fund the use of the system. The clinicians were able to manage their patients' heart failure conditions more effectively, because they had physiological data reported to them frequently to help in their decision-making (eg, for medication titration) and were alerted at the earliest sign of decompensation. Essential characteristics of the telemonitoring system that contributed to improved heart failure management included immediate self-care and clinical feedback (ie, teachable moments), how the system was easy and quick to use, and how the patients and clinicians perceived tangible benefits from telemonitoring. Some clinical concerns included ongoing costs of the telemonitoring system and increased clinical workload. A few patients did not want to be watched long-term while some were concerned they might become dependent on the system. The success of a telemonitoring system is highly dependent on its features and design. The essential system characteristics identified in this study should be considered when developing telemonitoring solutions.
Ayalasomayajula, Surya; Schuehly, Uwe; Pal, Parasar; Chen, Fabian; Zhou, Wei; Sunkara, Gangadhar; Langenickel, Thomas H
2018-05-01
Sacubitril/valsartan is indicated for the treatment of heart failure and reduced ejection fraction (HFrEF). Furosemide, a loop diuretic commonly used for the treatment of HFrEF, may be coadministered with sacubitril/valsartan in clinical practice. The effect of sacubitril/valsartan on the pharmacokinetics and pharmacodynamics of furosemide was evaluated in this open label, two-period, single-sequence study in healthy subjects. All subjects (n = 28) received 40 mg oral single-dose furosemide during period 1, followed by a washout of 2 days. In period 2, sacubitril/valsartan 200 mg (97/103 mg) was administered twice daily for 5 days and a single dose of 40 mg furosemide was coadministered on day 6. Serial plasma and urine samples were collected to determine the pharmacokinetics of furosemide and sacubitril/valsartan and the pharmacodynamics of furosemide. The point estimates and the associated 90% confidence intervals for pharmacokinetic parameters were evaluated. Coadministration of furosemide with sacubitril/valsartan decreased the maximum observed plasma concentration (C max ) [estimated geometric mean ratio (90% confidence interval): 0.50 (0.44, 0.56)], area under the plasma concentration-time curve (AUC) from time 0 to infinity [0.72 (0.67, 0.77)] and 24-h urinary excretion of furosemide [0.74 (0.69, 0.79)]. When coadministered with sacubitril/valsartan, 0-4-h, 4-8-h and 0-24-h diuresis in response to furosemide was reduced by ~7%, 21% and 0.2%, respectively, while natriuresis was reduced by ~ 28.5%, 7% and 15%, respectively. Post hoc analysis of the pivotal phase III Prospective comparison of ARNI with ACEI to Determine Impact on Global Mortality and morbidity in Heart Failure trial (PARADIGM-HF) indicated that the median furosemide dose was similar at baseline and at the end of the study in the sacubitril/valsartan group. Sacubitril/valsartan reduced plasma C max and AUC and 24-h urinary excretion of furosemide, while not significantly affecting its pharmacodynamic effects in healthy subjects. © 2018 Crown copyright. British Journal of Clinical Pharmacology © 2018 British Pharmacological Society.
Single-Parents' Persistence in Pursuit of Higher Education: A Case Study
ERIC Educational Resources Information Center
Poindexter, Beryle Jean
2017-01-01
The purpose of this qualitative case study is an exploratory study to examine what contributes to the failure of the persistence of non-residential single-parents pursuing a college degree. The participants of this study included ten non-residential single-parent students between the ages of 21 and 50. The site of the interviews was in the…
NASA Technical Reports Server (NTRS)
Weiss, Jerold L.; Hsu, John Y.
1986-01-01
The use of a decentralized approach to failure detection and isolation for use in restructurable control systems is examined. This work has produced: (1) A method for evaluating fundamental limits to FDI performance; (2) Application using flight recorded data; (3) A working control element FDI system with maximal sensitivity to critical control element failures; (4) Extensive testing on realistic simulations; and (5) A detailed design methodology involving parameter optimization (with respect to model uncertainties) and sensitivity analyses. This project has concentrated on detection and isolation of generic control element failures since these failures frequently lead to emergency conditions and since knowledge of remaining control authority is essential for control system redesign. The failures are generic in the sense that no temporal failure signature information was assumed. Thus, various forms of functional failures are treated in a unified fashion. Such a treatment results in a robust FDI system (i.e., one that covers all failure modes) but sacrifices some performance when detailed failure signature information is known, useful, and employed properly. It was assumed throughout that all sensors are validated (i.e., contain only in-spec errors) and that only the first failure of a single control element needs to be detected and isolated. The FDI system which has been developed will handle a class of multiple failures.
Use of Life-Test Data Analysis Methodology for Analyzing Undesirable Habitual Behavior
1979-07-06
of times to failu’e for the hardware subjected to life test. In the present context it has been round that detoxification provides a time that one may...the fact that resulting data generated by a single individual tend to belong to a classical distribution of times to failure. Detoxification is used...drug and its immediate toxic effects from his or her body and brain. Detoxification in this sense may result from inpatient or outpatient treatment at a
NASA Technical Reports Server (NTRS)
Keys, Andrew S.; Adams, James H.; Darty, Ronald C.; Patrick, Marshall C.; Johnson, Michael A.; Cressler, John D.
2008-01-01
Primary Objective: 1) A computational tool to accurately predict electronics performance in the presence of space radiation in support of spacecraft design: a) Total dose; b) Single Event Effects; and c) Mean Time Between Failure. (Developed as successor to CR ME96.) Secondary Objectives: 2) To provide a detailed description of the natural radiation environment in support of radiation health and instrument design: a) In deep space; b) Inside the magnetosphere; and c) Behind shielding.
Okut, Gokalp; Alp, Alper; Tatar, Erhan; Simsek, Cenk; Tugmen, Cem; Uslu, Adam
2017-02-01
We evaluated patients with nonmelanoma skin cancer after kidney transplant and the effects of immunosuppression reduction and switching to a mammalian target of rapamycin inhibitor drugs. Kidney transplant recipients were evaluated retrospectively from patient medical records (between January 2000 and December 2014). A 30% increase in serum creatinine was accepted as indicating renal failure progression. Of 18 patients included (mean follow-up 98 ± 66 mo), 7 (38.8%) had squamous cell carcinoma, 7 (38.8%) had Kaposi sarcoma, and 4 (22.2%) had basal cell carcinoma. At cancer diagnosis, average serum creatinine was 1.6 ± 0.7 mg/dL and proteinuria was 410 ± 766 mg/d. Immunosuppression regimen was changed in 15 patients (83.3%), with new regimen being a single-drug (only prednisolone) in 4 patients, double-drug in 6 patients, and triple-drug protocol in 8 patients. Eight patients were switched to a mammalian target of rapamycin inhibitor-based double (4 patients) or triple (4 patients) regimen. During follow-up after starting new treatment (average 46 ± 50 mo), 6 patients (33.3%) had progressive kidney failure (0 were receiving triple regimen). Those that progressed were using mammalian target of rapamycin inhibitor-based drugs relatively less (33% vs 50%), although often receiving a single-drug immunosuppression treatment (50% vs 8.3%). Three patients (33.3%) had acute rejection (2 receiving double and 1 receiving single immunosuppression treatment). Five patients (27.7%) had local recurrence of the primary tumor. Mammalian target of rapamycin inhibitor use was relatively less common in patients with tumor relapse (20% vs 46%). One patient died (heart failure), and 1 with chronic rejection returned to dialysis. Mammalian target of rapamycin inhibitorbased drugs could reduce local recurrence rate in kidney transplant recipients with nonmelanoma skin cancers. Aggressive reduction and/or cessation of immunosuppressive drugs after skin cancer can lead to graft rejection.
Study on Mechanical Properties of Hybrid Fiber Reinforced Concrete
NASA Astrophysics Data System (ADS)
He, Dongqing; Wu, Min; Jie, Pengyu
2017-12-01
Several common high elastic modulus fibers (steel fibers, basalt fibers, polyvinyl alcohol fibers) and low elastic modulus fibers (polypropylene fiber) are incorporated into the concrete, and its cube compressive strength, splitting tensile strength and flexural strength are studied. The test result and analysis demonstrate that single fiber and hybrid fiber will improve the integrity of the concrete at failure. The mechanical properties of hybrid steel fiber-polypropylene fiber reinforced concrete are excellent, and the cube compressive strength, splitting tensile strength and flexural strength respectively increase than plain concrete by 6.4%, 3.7%, 11.4%. Doped single basalt fiber or polypropylene fiber and basalt fibers hybrid has little effect on the mechanical properties of concrete. Polyvinyl alcohol fiber and polypropylene fiber hybrid exhibit ‘negative confounding effect’ on concrete, its splitting tensile and flexural strength respectively are reduced by 17.8% and 12.9% than the single-doped polyvinyl alcohol fiber concrete.
NASA Technical Reports Server (NTRS)
Berg, Melanie D.; LaBel, Kenneth A.
2018-01-01
The following are updated or new subjects added to the FPGA SEE Test Guidelines manual: academic versus mission specific device evaluation, single event latch-up (SEL) test and analysis, SEE response visibility enhancement during radiation testing, mitigation evaluation (embedded and user-implemented), unreliable design and its affects to SEE Data, testing flushable architectures versus non-flushable architectures, intellectual property core (IP Core) test and evaluation (addresses embedded and user-inserted), heavy-ion energy and linear energy transfer (LET) selection, proton versus heavy-ion testing, fault injection, mean fluence to failure analysis, and mission specific system-level single event upset (SEU) response prediction. Most sections within the guidelines manual provide information regarding best practices for test structure and test system development. The scope of this manual addresses academic versus mission specific device evaluation and visibility enhancement in IP Core testing.
NASA Technical Reports Server (NTRS)
Berg, Melanie D.; LaBel, Kenneth A.
2018-01-01
The following are updated or new subjects added to the FPGA SEE Test Guidelines manual: academic versus mission specific device evaluation, single event latch-up (SEL) test and analysis, SEE response visibility enhancement during radiation testing, mitigation evaluation (embedded and user-implemented), unreliable design and its affects to SEE Data, testing flushable architectures versus non-flushable architectures, intellectual property core (IP Core) test and evaluation (addresses embedded and user-inserted), heavy-ion energy and linear energy transfer (LET) selection, proton versus heavy-ion testing, fault injection, mean fluence to failure analysis, and mission specific system-level single event upset (SEU) response prediction. Most sections within the guidelines manual provide information regarding best practices for test structure and test system development. The scope of this manual addresses academic versus mission specific device evaluation and visibility enhancement in IP Core testing.
Application of single crystal superalloys for Earth-to-orbit propulsion systems
NASA Technical Reports Server (NTRS)
Dreshfield, R. L.; Parr, R. A.
1987-01-01
Single crystal superalloys were first identified as potentially useful engineering materials for aircraft gas turbine engines in the mid-1960's. Although they were not introduced into service as turbine blades in commercial aircraft engines until the early 1980's, they have subsequently accumulated tens of millions of flight hours in revenue producing service. The space shuttle main engine (SSME) and potential advanced earth-to-orbit propulsion systems impose severe conditions on turbopump turbine blades which for some potential failure modes are more severe than in aircraft gas turbines. Research activities which are directed at evaluating the potential for single crystal superalloys for application as turbopump turbine blades in the SSME and advanced rocket engines are discussed. The mechanical properties of these alloys are summarized and the effects of hydrogen are noted. The use of high gradient directional solidification and hot isostatic pressing to improve fatigue properties is also addressed.
The evaluation of the OSGLR algorithm for restructurable controls
NASA Technical Reports Server (NTRS)
Bonnice, W. F.; Wagner, E.; Hall, S. R.; Motyka, P.
1986-01-01
The detection and isolation of commercial aircraft control surface and actuator failures using the orthogonal series generalized likelihood ratio (OSGLR) test was evaluated. The OSGLR algorithm was chosen as the most promising algorithm based on a preliminary evaluation of three failure detection and isolation (FDI) algorithms (the detection filter, the generalized likelihood ratio test, and the OSGLR test) and a survey of the literature. One difficulty of analytic FDI techniques and the OSGLR algorithm in particular is their sensitivity to modeling errors. Therefore, methods of improving the robustness of the algorithm were examined with the incorporation of age-weighting into the algorithm being the most effective approach, significantly reducing the sensitivity of the algorithm to modeling errors. The steady-state implementation of the algorithm based on a single cruise linear model was evaluated using a nonlinear simulation of a C-130 aircraft. A number of off-nominal no-failure flight conditions including maneuvers, nonzero flap deflections, different turbulence levels and steady winds were tested. Based on the no-failure decision functions produced by off-nominal flight conditions, the failure detection performance at the nominal flight condition was determined. The extension of the algorithm to a wider flight envelope by scheduling the linear models used by the algorithm on dynamic pressure and flap deflection was also considered. Since simply scheduling the linear models over the entire flight envelope is unlikely to be adequate, scheduling of the steady-state implentation of the algorithm was briefly investigated.
Laser notching ceramics for reliable fracture toughness testing
Barth, Holly D.; Elmer, John W.; Freeman, Dennis C.; ...
2015-09-19
A new method for notching ceramics was developed using a picosecond laser for fracture toughness testing of alumina samples. The test geometry incorporated a single-edge-V-notch that was notched using picosecond laser micromachining. This method has been used in the past for cutting ceramics, and is known to remove material with little to no thermal effect on the surrounding material matrix. This study showed that laser-assisted-machining for fracture toughness testing of ceramics was reliable, quick, and cost effective. In order to assess the laser notched single-edge-V-notch beam method, fracture toughness results were compared to results from other more traditional methods, specificallymore » surface-crack in flexure and the chevron notch bend tests. Lastly, the results showed that picosecond laser notching produced precise notches in post-failure measurements, and that the measured fracture toughness results showed improved consistency compared to traditional fracture toughness methods.« less
Barack Obama Blindness (BOB): Absence of Visual Awareness to a Single Object.
Persuh, Marjan; Melara, Robert D
2016-01-01
In two experiments, we evaluated whether a perceiver's prior expectations could alone obliterate his or her awareness of a salient visual stimulus. To establish expectancy, observers first made a demanding visual discrimination on each of three baseline trials. Then, on a fourth, critical trial, a single, salient and highly visible object appeared in full view at the center of the visual field and in the absence of any competing visual input. Surprisingly, fully half of the participants were unaware of the solitary object in front of their eyes. Dramatically, observers were blind even when the only stimulus on display was the face of U.S. President Barack Obama. We term this novel, counterintuitive phenomenon, Barack Obama Blindness (BOB). Employing a method that rules out putative memory effects by probing awareness immediately after presentation of the critical stimulus, we demonstrate that the BOB effect is a true failure of conscious vision.
Barack Obama Blindness (BOB): Absence of Visual Awareness to a Single Object
Persuh, Marjan; Melara, Robert D.
2016-01-01
In two experiments, we evaluated whether a perceiver’s prior expectations could alone obliterate his or her awareness of a salient visual stimulus. To establish expectancy, observers first made a demanding visual discrimination on each of three baseline trials. Then, on a fourth, critical trial, a single, salient and highly visible object appeared in full view at the center of the visual field and in the absence of any competing visual input. Surprisingly, fully half of the participants were unaware of the solitary object in front of their eyes. Dramatically, observers were blind even when the only stimulus on display was the face of U.S. President Barack Obama. We term this novel, counterintuitive phenomenon, Barack Obama Blindness (BOB). Employing a method that rules out putative memory effects by probing awareness immediately after presentation of the critical stimulus, we demonstrate that the BOB effect is a true failure of conscious vision. PMID:27047362
2014-09-11
LiCoO2 and LiFePO4 chemistry 18650 lithium-ion batteries were constructed and data was obtained and analyzed for abuse and failure tests. Observations...22308 Lithium-ion batteries Failure Heat propagation 18650 cells LiCoO2 LiFePO4 ii iii Contents 1.0 Background...Corp., Taipei, Taiwan) or LiFePO4 cathode chemistry (APR18650 1100mAh 3.3V, A123 Systems, Waltham, Massachusetts, USA). First, a single LiCoO2
Hepatitis A and parvovirus B19 infections in an infant with fulminant hepatic failure.
Ozçay, Figen; Bikmaz, Y Emre; Canan, Oğuz; Ozbek, Namik
2006-06-01
Acute viral hepatitis with hepatitis A, B, C, D, and E viruses in the etiology of fulminant hepatic failure either single or in combinations has been described. Parvovirus B19 is also an etiologic agent of acute liver failure and hepatitis-associated aplastic anemia. We present a patient diagnosed with fulminant hepatitis A referred for liver transplantation. Parvovirus B19 superinfection was detected when the patient developed anemia during the course of the disease. We discuss possible roles of both viruses in fulminant hepatitis and pure red cell aplasia.
Petersen, Maya L; LeDell, Erin; Schwab, Joshua; Sarovar, Varada; Gross, Robert; Reynolds, Nancy; Haberer, Jessica E; Goggin, Kathy; Golin, Carol; Arnsten, Julia; Rosen, Marc I; Remien, Robert H; Etoori, David; Wilson, Ira B; Simoni, Jane M; Erlen, Judith A; van der Laan, Mark J; Liu, Honghu; Bangsberg, David R
2015-05-01
Regular HIV RNA testing for all HIV-positive patients on antiretroviral therapy (ART) is expensive and has low yield since most tests are undetectable. Selective testing of those at higher risk of failure may improve efficiency. We investigated whether a novel analysis of adherence data could correctly classify virological failure and potentially inform a selective testing strategy. Multisite prospective cohort consortium. We evaluated longitudinal data on 1478 adult patients treated with ART and monitored using the Medication Event Monitoring System (MEMS) in 16 US cohorts contributing to the MACH14 consortium. Because the relationship between adherence and virological failure is complex and heterogeneous, we applied a machine-learning algorithm (Super Learner) to build a model for classifying failure and evaluated its performance using cross-validation. Application of the Super Learner algorithm to MEMS data, combined with data on CD4 T-cell counts and ART regimen, significantly improved classification of virological failure over a single MEMS adherence measure. Area under the receiver operating characteristic curve, evaluated on data not used in model fitting, was 0.78 (95% confidence interval: 0.75 to 0.80) and 0.79 (95% confidence interval: 0.76 to 0.81) for failure defined as single HIV RNA level >1000 copies per milliliter or >400 copies per milliliter, respectively. Our results suggest that 25%-31% of viral load tests could be avoided while maintaining sensitivity for failure detection at or above 95%, for a cost savings of $16-$29 per person-month. Our findings provide initial proof of concept for the potential use of electronic medication adherence data to reduce costs through behavior-driven HIV RNA testing.
Hohmann, Erik; König, Anya; Kat, Cor-Jacques; Glatt, Vaida; Tetsworth, Kevin; Keough, Natalie
2018-07-01
The purpose of this study was to perform a systematic review and meta-analysis comparing single- and double-row biomechanical studies to evaluate load to failure, mode of failure and gap formation. A systematic review of MEDLINE, Embase, Scopus and Google Scholar was performed from 1990 through 2016. The inclusion criteria were: documentation of ultimate load to failure, failure modes and documentation of elongation or gap formation. Studies were excluded if the study protocol did not use human specimens. Publication bias was assessed by funnel plot and Egger's test. The risk of bias was established using the Cochrane Collaboration's risk of bias tool. Heterogeneity was assessed using χ 2 and I 2 statistic. Eight studies were included. The funnel plot was asymmetric suggesting publication bias, which was confirmed by Egger's test (p = 0.04). The pooled estimate for load to failure demonstrated significant differences (SMD 1.228, 95% CI: 0.55-5.226, p = 0.006, I 2 = 60.47%), favouring double-row repair. There were no differences for failure modes. The pooled estimate for elongation/gap formation demonstrated significant differences (SMD 0.783, 95% CI: 0.169-1.398, p = 0.012, I 2 = 58.8%), favouring double-row repair. The results of this systematic review and meta-analysis suggest that double-row repair is able to tolerate a significantly greater load to failure. Gap formation was also significantly lower in the double-row repair group, but both of these findings should be interpreted with caution because of the inherent interstudy heterogeneity. Systematic review and meta-analysis.
Harraz, Ahmed M.; El-Assmy, Ahmed; Mahmoud, Osama; Elbakry, Amr A.; Tharwat, Mohamed; Omar, Helmy; Farg, Hashim; Laymon, Mahmoud; Mosbah, Ahmed
2015-01-01
Objective To identify patient and stricture characteristics predicting failure after direct vision internal urethrotomy (DVIU) for single and short (<2 cm) bulbar urethral strictures. Patients and methods We retrospectively analysed the records of adult patients who underwent DVIU between January 2002 and 2013. The patients’ demographics and stricture characteristics were analysed. The primary outcome was procedure failure, defined as the need for regular self-dilatation (RSD), redo DVIU or substitution urethroplasty. Predictors of failure were analysed. Results In all, 430 adult patients with a mean (SD) age of 50 (15) years were included. The main causes of stricture were idiopathic followed by iatrogenic in 51.6% and 26.3% of patients, respectively. Most patients presented with obstructive lower urinary tract symptoms (68.9%) and strictures were proximal bulbar, i.e. just close to the external urethral sphincter, in 35.3%. The median (range) follow-up duration was 29 (3–132) months. In all, 250 (58.1%) patients did not require any further instrumentation, while RSD was maintained in 116 (27%) patients, including 28 (6.5%) who required a redo DVIU or urethroplasty. In 64 (6.5%) patients, a redo DVIU or urethroplasty was performed. On multivariate analysis, older age at presentation [odds ratio (OR) 1.017; P = 0.03], obesity (OR 1.664; P = 0.015), and idiopathic strictures (OR 3.107; P = 0.035) were independent predictors of failure after DVIU. Conclusion The failure rate after DVIU accounted for 41.8% of our present cohort with older age at presentation, obesity, and idiopathic strictures independent predictors of failure after DVIU. This information is important in counselling patients before surgery. PMID:26609447
Harraz, Ahmed M; El-Assmy, Ahmed; Mahmoud, Osama; Elbakry, Amr A; Tharwat, Mohamed; Omar, Helmy; Farg, Hashim; Laymon, Mahmoud; Mosbah, Ahmed
2015-12-01
To identify patient and stricture characteristics predicting failure after direct vision internal urethrotomy (DVIU) for single and short (<2 cm) bulbar urethral strictures. We retrospectively analysed the records of adult patients who underwent DVIU between January 2002 and 2013. The patients' demographics and stricture characteristics were analysed. The primary outcome was procedure failure, defined as the need for regular self-dilatation (RSD), redo DVIU or substitution urethroplasty. Predictors of failure were analysed. In all, 430 adult patients with a mean (SD) age of 50 (15) years were included. The main causes of stricture were idiopathic followed by iatrogenic in 51.6% and 26.3% of patients, respectively. Most patients presented with obstructive lower urinary tract symptoms (68.9%) and strictures were proximal bulbar, i.e. just close to the external urethral sphincter, in 35.3%. The median (range) follow-up duration was 29 (3-132) months. In all, 250 (58.1%) patients did not require any further instrumentation, while RSD was maintained in 116 (27%) patients, including 28 (6.5%) who required a redo DVIU or urethroplasty. In 64 (6.5%) patients, a redo DVIU or urethroplasty was performed. On multivariate analysis, older age at presentation [odds ratio (OR) 1.017; P = 0.03], obesity (OR 1.664; P = 0.015), and idiopathic strictures (OR 3.107; P = 0.035) were independent predictors of failure after DVIU. The failure rate after DVIU accounted for 41.8% of our present cohort with older age at presentation, obesity, and idiopathic strictures independent predictors of failure after DVIU. This information is important in counselling patients before surgery.
Petersen, Maya L.; LeDell, Erin; Schwab, Joshua; Sarovar, Varada; Gross, Robert; Reynolds, Nancy; Haberer, Jessica E.; Goggin, Kathy; Golin, Carol; Arnsten, Julia; Rosen, Marc; Remien, Robert; Etoori, David; Wilson, Ira; Simoni, Jane M.; Erlen, Judith A.; van der Laan, Mark J.; Liu, Honghu; Bangsberg, David R
2015-01-01
Objective Regular HIV RNA testing for all HIV positive patients on antiretroviral therapy (ART) is expensive and has low yield since most tests are undetectable. Selective testing of those at higher risk of failure may improve efficiency. We investigated whether a novel analysis of adherence data could correctly classify virological failure and potentially inform a selective testing strategy. Design Multisite prospective cohort consortium. Methods We evaluated longitudinal data on 1478 adult patients treated with ART and monitored using the Medication Event Monitoring System (MEMS) in 16 United States cohorts contributing to the MACH14 consortium. Since the relationship between adherence and virological failure is complex and heterogeneous, we applied a machine-learning algorithm (Super Learner) to build a model for classifying failure and evaluated its performance using cross-validation. Results Application of the Super Learner algorithm to MEMS data, combined with data on CD4+ T cell counts and ART regimen, significantly improved classification of virological failure over a single MEMS adherence measure. Area under the ROC curve, evaluated on data not used in model fitting, was 0.78 (95% CI: 0.75, 0.80) and 0.79 (95% CI: 0.76, 0.81) for failure defined as single HIV RNA level >1000 copies/ml or >400 copies/ml, respectively. Our results suggest 25–31% of viral load tests could be avoided while maintaining sensitivity for failure detection at or above 95%, for a cost savings of $16–$29 per person-month. Conclusions Our findings provide initial proof-of-concept for the potential use of electronic medication adherence data to reduce costs through behavior-driven HIV RNA testing. PMID:25942462
Tamary, Hannah; Nishri, Daniella; Yacobovich, Joanne; Zilber, Rama; Dgany, Orly; Krasnov, Tanya; Aviner, Shraga; Stepensky, Polina; Ravel-Vilk, Shoshana; Bitan, Menachem; Kaplinsky, Chaim; Ben Barak, Ayelet; Elhasid, Ronit; Kapelusnik, Joseph; Koren, Ariel; Levin, Carina; Attias, Dina; Laor, Ruth; Yaniv, Isaac; Rosenberg, Philip S; Alter, Blanche P
2010-08-01
Inherited bone marrow failure syndromes are rare genetic disorders characterized by bone marrow failure, congenital anomalies, and cancer predisposition. Available single disease registries provide reliable information regarding natural history, efficacy and side effects of treatments, and contribute to the discovery of the causative genes. However, these registries could not shed light on the true incidence of the various syndromes. We, therefore, established an Israeli national registry in order to investigate the relative frequency of each of these syndromes and their complications. Patients were registered by their hematologists in all 16 medical centers in Israel. We included patients with Fanconi anemia, severe congenital neutropenia, Diamond-Blackfan anemia, congenital amegakaryocytic thrombocytopenia, dyskeratosis congenita, Shwachman-Diamond syndrome, and thrombocytopenia with absent radii. One hundred and twenty-seven patients diagnosed between 1966 and 2007 were registered. Fifty-two percent were found to have Fanconi anemia, 17% severe congenital neutropenia, 14% Diamond-Blackfan anemia, 6% congenital amegakaryocytic thrombocytopenia, 5% dyskeratosis congenita, 2% Shwachman-Diamond syndrome, and 2% thrombocytopenia with absent radii. No specific diagnosis was made in only 2 patients. Of the thirty patients (24%) developing severe bone marrow failure, 80% had Fanconi anemia. Seven of 9 patients with leukemia had Fanconi anemia, as did all 6 with solid tumors. Thirty-four patients died from their disease; 25 (74%) had Fanconi anemia and 6 (17%) had severe congenital neutropenia. This is the first comprehensive population-based study evaluating the incidence and complications of the different inherited bone marrow failure syndromes. By far the most common disease was Fanconi anemia, followed by severe congenital neutropenia and Diamond-Blackfan anemia. Fanconi anemia carried the worst prognosis, with severe bone marrow failure and cancer susceptibility. Diamond-Blackfan anemia had the best prognosis. The data presented provide a rational basis for prevention programs and longitudinal surveillance of the complications of inherited bone marrow failure syndromes.
NASA Technical Reports Server (NTRS)
Williams, F. E.; Lemon, R. S.
1974-01-01
The investigation of single actuator failures on the space shuttle solid rocket booster required the analysis of both square pattern and diamond pattern actuator configurations. It was determined that for failures occuring near or prior to the region of maximum dynamic pressure, control gain adjustments can be used to achieve virtually nominal mid-boost vehicle behavior. A distinct worst case failure condition was established near staging that could significantly delay staging. It is recommended that the square pattern be retained as a viable alternative to the baseline diamond pattern because the staging transient is better controlled resulting in earlier staging.
Coupled Electro-Thermal Simulations of Single Event Burnout in Power Diodes
NASA Astrophysics Data System (ADS)
Albadri, A. M.; Schrimpf, R. D.; Walker, D. G.; Mahajan, S. V.
2005-12-01
Power diodes may undergo destructive failures when they are struck by high-energy particles during the off state (high reverse-bias voltage). This paper describes the failure mechanism using a coupled electro-thermal model. The specific case of a 3500-V diode is considered and it is shown that the temperatures reached when high voltages are applied are sufficient to cause damage to the constituent materials of the diode. The voltages at which failure occurs (e.g., 2700 V for a 17-MeV carbon ion) are consistent with previously reported data. The simulation results indicate that the catastrophic failures result from local heating caused by avalanche multiplication of ion-generated carriers.
Investigation of HZETRN 2010 as a Tool for Single Event Effect Qualification of Avionics Systems
NASA Technical Reports Server (NTRS)
Rojdev, Kristina; Koontz, Steve; Atwell, William; Boeder, Paul
2014-01-01
NASA's future missions are focused on long-duration deep space missions for human exploration which offers no options for a quick emergency return to Earth. The combination of long mission duration with no quick emergency return option leads to unprecedented spacecraft system safety and reliability requirements. It is important that spacecraft avionics systems for human deep space missions are not susceptible to Single Event Effect (SEE) failures caused by space radiation (primarily the continuous galactic cosmic ray background and the occasional solar particle event) interactions with electronic components and systems. SEE effects are typically managed during the design, development, and test (DD&T) phase of spacecraft development by using heritage hardware (if possible) and through extensive component level testing, followed by system level failure analysis tasks that are both time consuming and costly. The ultimate product of the SEE DD&T program is a prediction of spacecraft avionics reliability in the flight environment produced using various nuclear reaction and transport codes in combination with the component and subsystem level radiation test data. Previous work by Koontz, et al.1 utilized FLUKA, a Monte Carlo nuclear reaction and transport code, to calculate SEE and single event upset (SEU) rates. This code was then validated against in-flight data for a variety of spacecraft and space flight environments. However, FLUKA has a long run-time (on the order of days). CREME962, an easy to use deterministic code offering short run times, was also compared with FLUKA predictions and in-flight data. CREME96, though fast and easy to use, has not been updated in several years and underestimates secondary particle shower effects in spacecraft structural shielding mass. Thus, this paper will investigate the use of HZETRN 20103, a fast and easy to use deterministic transport code, similar to CREME96, that was developed at NASA Langley Research Center primarily for flight crew ionizing radiation dose assessments. HZETRN 2010 includes updates to address secondary particle shower effects more accurately, and might be used as another tool to verify spacecraft avionics system reliability in space flight SEE environments.
Wittke, Andreas; von Stengel, Simon; Hettchen, Michael; Fröhlich, Michael; Giessing, Jürgen; Lell, Michael; Scharf, Michael; Bebenek, Michael; Kohl, Matthias; Kemmler, Wolfgang
2017-01-01
High intensity (resistance exercise) training (HIT) defined as a "single set resistance exercise to muscular failure" is an efficient exercise method that allows people with low time budgets to realize an adequate training stimulus. Although there is an ongoing discussion, recent meta-analysis suggests the significant superiority of multiple set (MST) methods for body composition and strength parameters. The aim of this study is to determine whether additional protein supplementation may increase the effect of a HIT-protocol on body composition and strength to an equal MST-level. One hundred and twenty untrained males 30-50 years old were randomly allocated to three groups: (a) HIT, (b) HIT and protein supplementation (HIT&P), and (c) waiting-control (CG) and (after cross-over) high volume/high-intensity-training (HVHIT). HIT was defined as "single set to failure protocol" while HVHIT consistently applied two equal sets. Protein supplementation provided an overall intake of 1.5-1.7 g/kg/d/body mass. Primary study endpoint was lean body mass (LBM). LBM significantly improved in all exercise groups ( p ≤ 0.043); however only HIT&P and HVHIT differ significantly from control ( p ≤ 0.002). HIT diverges significantly from HIT&P ( p = 0.017) and nonsignificantly from HVHIT ( p = 0.059), while no differences were observed for HIT&P versus HVHIT ( p = 0.691). In conclusion, moderate to high protein supplementation significantly increases the effects of a HIT-protocol on LBM in middle-aged untrained males.
NEBIVOLOL, BUT NOT METOPROLOL, LOWERS BLOOD PRESSURE IN NITRIC OXIDE-SENSITIVE HUMAN HYPERTENSION
Okamoto, Luis E.; Gamboa, Alfredo; Shibao, Cyndya; Arnold, Amy C.; Choi, Leena; Black, Bonnie K.; Raj, Satish R.; Robertson, David; Biaggioni, Italo
2014-01-01
Nebivolol, unlike other selective β1-receptor blockers, induces vasodilation attributable to increased nitric oxide (NO) bioavailability. The relative contribution of this mechanism to the blood pressure (BP) lowering effects of nebivolol is unclear because it is normally masked by baroreflex buffering. Autonomic failure provides a unique model of hypertension devoid of autonomic modulation but sensitive to the hypotensive effects of NO potentiation. We tested the hypothesis that nebivolol would decrease BP in these patients through a mechanism independent of β-blockade. We randomized 20 autonomic failure patients with supine hypertension (14 men, 69±2 yrs.) to receive a single oral dose of placebo, nebivolol 5 mg, metoprolol 50 mg (negative control) and sildenafil 25 mg (positive control) on separate nights in a double-blind, crossover study. Supine BP was monitored every 2 hours from 8pm to 8am. Compared to placebo, sildenafil and nebivolol decreased systolic BP (SBP) during the night (P<0.001 and P=0.036, by mixed-effects model, maximal SBP reduction 8-hours postdrug of −20±6 and −24±9 mm Hg, respectively), whereas metoprolol had no effect. In a sub-analysis, we divided patients into sildenafil responders (BP fall >20 mmHg at 4am) and non-responders. Nebivolol significantly lowered SBP in sildenafil responders (−44±13 mmHg) but not in non-responders (1±11 mm Hg). Despite lowering nighttime BP, nebivolol did not worsen morning orthostatic tolerance compared with placebo. In conclusion, nebivolol effectively lowered supine hypertension in autonomic failure, independent of ß1-blockade. These results are consistent with the hypothesis that NO potentiation contributes significantly to the antihypertensive effect of nebivolol. PMID:25267802
ERIC Educational Resources Information Center
Barker, Bruce O.; Petersen, Paul D.
This paper explores the fault-tree analysis approach to isolating failure modes within a system. Fault tree investigates potentially undesirable events and then looks for failures in sequence that would lead to their occurring. Relationships among these events are symbolized by AND or OR logic gates, AND used when single events must coexist to…
Probabilistic Analysis of Space Shuttle Body Flap Actuator Ball Bearings
NASA Technical Reports Server (NTRS)
Oswald, Fred B.; Jett, Timothy R.; Predmore, Roamer E.; Zaretsky, Erin V.
2007-01-01
A probabilistic analysis, using the 2-parameter Weibull-Johnson method, was performed on experimental life test data from space shuttle actuator bearings. Experiments were performed on a test rig under simulated conditions to determine the life and failure mechanism of the grease lubricated bearings that support the input shaft of the space shuttle body flap actuators. The failure mechanism was wear that can cause loss of bearing preload. These tests established life and reliability data for both shuttle flight and ground operation. Test data were used to estimate the failure rate and reliability as a function of the number of shuttle missions flown. The Weibull analysis of the test data for a 2-bearing shaft assembly in each body flap actuator established a reliability level of 99.6 percent for a life of 12 missions. A probabilistic system analysis for four shuttles, each of which has four actuators, predicts a single bearing failure in one actuator of one shuttle after 22 missions (a total of 88 missions for a 4-shuttle fleet). This prediction is comparable with actual shuttle flight history in which a single actuator bearing was found to have failed by wear at 20 missions.
Probabilistic Analysis of Space Shuttle Body Flap Actuator Ball Bearings
NASA Technical Reports Server (NTRS)
Oswald, Fred B.; Jett, Timothy R.; Predmore, Roamer E.; Zaretsky, Erwin V.
2008-01-01
A probabilistic analysis, using the 2-parameter Weibull-Johnson method, was performed on experimental life test data from space shuttle actuator bearings. Experiments were performed on a test rig under simulated conditions to determine the life and failure mechanism of the grease lubricated bearings that support the input shaft of the space shuttle body flap actuators. The failure mechanism was wear that can cause loss of bearing preload. These tests established life and reliability data for both shuttle flight and ground operation. Test data were used to estimate the failure rate and reliability as a function of the number of shuttle missions flown. The Weibull analysis of the test data for the four actuators on one shuttle, each with a 2-bearing shaft assembly, established a reliability level of 96.9 percent for a life of 12 missions. A probabilistic system analysis for four shuttles, each of which has four actuators, predicts a single bearing failure in one actuator of one shuttle after 22 missions (a total of 88 missions for a 4-shuttle fleet). This prediction is comparable with actual shuttle flight history in which a single actuator bearing was found to have failed by wear at 20 missions.
van Riet, Evelien E S; Hoes, Arno W; Limburg, Alexander; van der Hoeven, Henk; Landman, Marcel A J; Rutten, Frans H
2014-01-08
Most patients with heart failure are diagnosed and managed in primary care, however, underdiagnosis and undertreatment are common. We assessed whether implementation of a diagnostic-therapeutic strategy improves functionality, health-related quality of life, and uptake of heart failure medication in primary care. A selective screening study followed by a single-blind cluster randomized trial in primary care. The study population consists of patients aged 65 years or over who presented themselves to the general practitioner in the previous 12 months with shortness of breath on exertion. Patients already known with established heart failure, confirmed by echocardiography, are excluded. Diagnostic investigations include history taking, physical examination, electrocardiography, and serum N-terminal pro B-type natriuretic peptide levels. Only participants with an abnormal electrocardiogram or an N-terminal pro B-type natriuretic peptide level exceeding the exclusionary cutpoint for non-acute onset heart failure (> 15 pmol/L (≈ 125 pg/ml)) will undergo open-access echocardiography. The diagnosis of heart failure (with reduced or preserved ejection fraction) is established by an expert panel consisting of two cardiologists and a general practitioner, according to the criteria of the European Society of Cardiology guidelines.Patients with newly established heart failure are allocated to either the 'care as usual' group or the 'intervention' group. Randomization is at the level of the general practitioner. In the intervention group general practitioners receive a single half-day training in heart failure management and the use of a structured up-titration scheme. All participants fill out quality of life questionnaires at baseline and after six months of follow-up. A six-minute walking test will be performed in patients with heart failure. Information on medication and hospitalization rates is extracted from the electronic medical files of the general practitioners. This study will provide information on the prevalence of unrecognized heart failure in elderly with shortness of breath on exertion, and the randomized comparison will reveal whether management based on a half-day training of general practitioners in the practical application of an up-titration scheme results in improvements in functionality, health-related quality of life, and uptake of heart failure medication in heart failure patients compared to care as usual. ClinicalTrials.gov NCT01202006.
Fatigue Failure of External Hexagon Connections on Cemented Implant-Supported Crowns.
Malta Barbosa, João; Navarro da Rocha, Daniel; Hirata, Ronaldo; Freitas, Gileade; Bonfante, Estevam A; Coelho, Paulo G
2018-01-17
To evaluate the probability of survival and failure modes of different external hexagon connection systems restored with anterior cement-retained single-unit crowns. The postulated null hypothesis was that there would be no differences under accelerated life testing. Fifty-four external hexagon dental implants (∼4 mm diameter) were used for single cement-retained crown replacement and divided into 3 groups: (3i) Full OSSEOTITE, Biomet 3i (n = 18); (OL) OEX P4, Osseolife Implants (n = 18); and (IL) Unihex, Intra-Lock International (n = 18). Abutments were torqued to the implants, and maxillary central incisor crowns were cemented and subjected to step-stress-accelerated life testing in water. Use-level probability Weibull curves and probability of survival for a mission of 100,000 cycles at 200 N (95% 2-sided confidence intervals) were calculated. Stereo and scanning electron microscopes were used for failure inspection. The beta values for 3i, OL, and IL (1.60, 1.69, and 1.23, respectively) indicated that fatigue accelerated the failure of the 3 groups. Reliability for the 3i and OL (41% and 68%, respectively) was not different between each other, but both were significantly lower than IL group (98%). Abutment screw fracture was the failure mode consistently observed in all groups. Because the reliability was significantly different between the 3 groups, our postulated null hypothesis was rejected.
Ciurea, Stefan O; de Lima, Marcos; Cano, Pedro; Korbling, Martin; Giralt, Sergio; Shpall, Elizabeth J; Wang, Xuemei; Thall, Peter F; Champlin, Richard E; Fernandez-Vina, Marcelo
2009-10-27
BACKGROUND.: Although donor-specific anti-human leukocyte antigen (HLA) antibodies (DSA) have been implicated in graft rejection in solid organ transplantation, their role in hematopoietic stem-cell transplantation remains unclear. METHODS.: To address the hypothesis that the presence of DSA contributes to the development graft failure, we tested 24 consecutive patients for the presence of anti-HLA antibodies determined by a sensitive and specific solid-phase/single-antigen assay. The study included a total of 28 haploidentical transplants, each with 2 to 5 HLA allele mismatches, at a single institution, from September 2005 to August 2008. RESULTS.: DSA were detected in five patients (21%). Three of four (75%) patients with DSA before the first transplant failed to engraft, compared with 1 of 20 (5%) without DSA (P=0.008). All four patients who experienced primary graft failure had second haploidentical transplants. One patient developed a second graft failure with persistent high DSA levels, whereas three engrafted, two of them in the absence of DSA. No other known factors that could negatively influence engraftment were associated with the development of graft failure in these patients. CONCLUSIONS.: These results suggest that donor-specific anti-HLA antibodies are associated with a high rate of graft rejection in patients undergoing haploidentical stem-cell transplantation. Anti-HLA sensitization should be evaluated routinely in hematopoietic stem-cell transplantation with HLA mismatched donors.
Rebbeck, Timothy R.; Weber, Anita L.; Walker, Amy H.; Stefflova, Klara; Tran, Teo V.; Spangler, Elaine; Chang, Bao-Li; Zeigler-Johnson, Charnita M.
2010-01-01
Background Disparities in cancer defined by race, age, or gender are well established. However, demographic metrics are surrogates for the complex contributions of genotypes, exposures, health care, socioeconomic and sociocultural environment, and many other factors. Macro-environmental factors represent novel surrogates for exposures, lifestyle and other factors that are difficult to measure but may influence cancer outcomes. Methods We applied a “multilevel molecular epidemiology” approach using a prospective cohort of 444 White prostate cancer cases who underwent prostatectomy and were followed until biochemical failure (BF) or censoring without BF. We applied Cox regression models to test for joint effects of 86 genome-wide association study-identified genotypes and macro-environmental contextual effects after geocoding all cases to their residential census tracts. All analyses were adjusted for age at diagnosis and tumor aggressiveness. Results Residents living in macroenvironments with a high proportion of older single heads of household, high rates of vacant housing, or high unemployment had shorter time until BF post-surgery after adjustment for patient age and tumor aggressiveness. After correction for multiple testing, genotypes alone did not predict time to BF, but interactions predicting time to BF were observed for MSMB (rs10993994) and percent of older single head of households (p=0.0004), and for HNF1B/TCF2 (rs4430796) and macroenvironment per capita income (p=0.0002). Conclusions Context-specific macro-environmental effects of genotype may improve the ability to identify groups that may experience poor prostate cancer outcomes. Impact Risk estimation and clinical translation of genotype information may require an understanding of both individual-level and macroenvironmental context. PMID:20826827
Rebbeck, Timothy R; Weber, Anita L; Walker, Amy H; Stefflova, Klara; Tran, Teo V; Spangler, Elaine; Chang, Bao-Li; Zeigler-Johnson, Charnita M
2010-09-01
Disparities in cancer defined by race, age, or gender are well established. However, demographic metrics are surrogates for the complex contributions of genotypes, exposures, health care, socioeconomic and sociocultural environment, and many other factors. Macroenvironmental factors represent novel surrogates for exposures, lifestyle, and other factors that are difficult to measure but might influence cancer outcomes. We applied a "multilevel molecular epidemiology" approach using a prospective cohort of 444 White prostate cancer cases who underwent prostatectomy and were followed until biochemical failure (BF) or censoring without BF. We applied Cox regression models to test for joint effects of 86 genome-wide association study-identified genotypes and macroenvironment contextual effects after geocoding all cases to their residential census tracts. All analyses were adjusted for age at diagnosis and tumor aggressiveness. Residents living in census tracts with a high proportion of older single heads of household, high rates of vacant housing, or high unemployment had shorter time until BF postsurgery after adjustment for patient age and tumor aggressiveness. After correction for multiple testing, genotypes alone did not predict time to BF, but interactions predicting time to BF were observed for MSMB (rs10993994) and percentage of older single heads of households (P = 0.0004), and for HNF1B/TCF2 (rs4430796) and census tract per capita income (P = 0.0002). The context-specific macroenvironmental effects of genotype might improve the ability to identify groups that might experience poor prostate cancer outcomes. Risk estimation and clinical translation of genotype information might require an understanding of both individual- and macroenvironment-level context. (c) 2010 AACR.
Feng, Qishuai; Shen, Yajing; Fu, Yingjie; Muroski, Megan E.; Zhang, Peng; Wang, Qiaoyue; Xu, Chang; Lesniak, Maciej S.; Li, Gang; Cheng, Yu
2017-01-01
Inorganic nanoparticles with unique physical properties have been explored as nanomedicines for brain tumor treatment. However, the clinical applications of the inorganic formulations are often hindered by the biological barriers and failure to be bioeliminated. The size of the nanoparticle is an essential design parameter which plays a significant role to affect the tumor targeting and biodistribution. Here, we report a feasible approach for the assembly of gold nanoparticles into ~80 nm nanospheres as a drug delivery platform for enhanced retention in brain tumors with the ability to be dynamically switched into the single formulation for excretion. These nanoassemblies can target epidermal growth factor receptors on cancer cells and are responsive to tumor microenvironmental characteristics, including high vascular permeability and acidic and redox conditions. Anticancer drug release was controlled by a pH-responsive mechanism. Intracellular L-glutathione (GSH) triggered the complete breakdown of nanoassemblies to single gold nanoparticles. Furthermore, in vivo studies have shown that nanospheres display enhanced tumor-targeting efficiency and therapeutic effects relative to single-nanoparticle formulations. Hence, gold nanoassemblies present an effective targeting strategy for brain tumor treatment. PMID:28638474
The fatigue damage behavior of a single crystal superalloy
NASA Technical Reports Server (NTRS)
Mcgaw, Michael A.
1988-01-01
The uniaxial fatigue behavior of a single crystal superalloy, PWA 1480, is described. Both monotonic tensile and constant amplitude fatigue tests were conducted at room temperature, in an effort to assess the applicability of polycrystalline-based fatigue life prediction methods to a single crystal superalloy. The observed constant amplitude behavior correlated best using a stress-based life criterion. Nearly all specimens failed at surface or slightly subsurface microporosity; this is thought to be responsible for the unusually large amount of scatter in the test results. An additional term is developed in the stress-life equation for the purpose of accounting for the effect of microporosity on fatigue life. The form chosen is a function of the effective area of the failure-producing microporosity projected on a plane perpendicular to the loading axis, as well as the applied stress. This additional term correlated the data to within factors of two on life. Although speculative, extrapolation of the microporosity relation to zero micropore area indicates that approximately an order of magnitude improvement in fatigue life should result.
Feng, Qishuai; Shen, Yajing; Fu, Yingjie; Muroski, Megan E; Zhang, Peng; Wang, Qiaoyue; Xu, Chang; Lesniak, Maciej S; Li, Gang; Cheng, Yu
2017-01-01
Inorganic nanoparticles with unique physical properties have been explored as nanomedicines for brain tumor treatment. However, the clinical applications of the inorganic formulations are often hindered by the biological barriers and failure to be bioeliminated. The size of the nanoparticle is an essential design parameter which plays a significant role to affect the tumor targeting and biodistribution. Here, we report a feasible approach for the assembly of gold nanoparticles into ~80 nm nanospheres as a drug delivery platform for enhanced retention in brain tumors with the ability to be dynamically switched into the single formulation for excretion. These nanoassemblies can target epidermal growth factor receptors on cancer cells and are responsive to tumor microenvironmental characteristics, including high vascular permeability and acidic and redox conditions. Anticancer drug release was controlled by a pH-responsive mechanism. Intracellular L-glutathione (GSH) triggered the complete breakdown of nanoassemblies to single gold nanoparticles. Furthermore, in vivo studies have shown that nanospheres display enhanced tumor-targeting efficiency and therapeutic effects relative to single-nanoparticle formulations. Hence, gold nanoassemblies present an effective targeting strategy for brain tumor treatment.
"If at first you don't succeed": using failure to improve teaching.
Pinsky, L E; Irby, D M
1997-11-01
The authors surveyed a group of distinguished clinical teachers regarding episodes of failure that had subsequently led to improvements in their teaching. Specifically, they examined how these teachers had used reflection on failed approaches as a tool for experiential learning. The respondents believed that failures were as important as successes in learning to be a good teacher. Using qualitative content analysis of the respondents' comments, the authors identified eight common types of failure associated with each of the three phases of teaching: planning, teaching, and reflection. Common failures associated with the planning stage were misjudging learners, lack of preparation, presenting too much content, lack of purpose, and difficulties with audiovisuals. The primary failure associated with actual teaching was inflexibly using a single teaching method. In the reflection phase, respondents said they most often realized that they had made one of two common errors: selecting the wrong teaching strategy or incorrectly implementing a sound strategy. For each identified failure, the respondents made recommendations for improvement. The deliberative process that had guided planning, teaching, and reflecting had helped all of them transform past failures into successes.
Mechanism of electromigration failure in Damascene processed copper interconnects
NASA Astrophysics Data System (ADS)
Michael, Nancy Lyn
2002-11-01
A major unresolved issue in Cu interconnect reliability is the interface role in the failure mechanism of real structures. The present study investigates failure in single-level damascene Cu interconnects with variations in interface condition, passivation and barrier, and linewidth. In the first phase, accelerated electromigration testing of 0.25mum Cu interconnects capped with SiN or SiCN, shows that lifetime and failure mode vary with capping layer. The first mode, seen primarily in SiN samples, is characterized by gradual resistance increase and extensive interface damage, believed to result from failure led by interface electromigration. The competing failure mode, found in SiCN capped samples, is characterized by abrupt resistance increase and localized voiding. The second phase fixes SiCN as the capping material and varies barrier material and line width. The three barrier materials, Ta, TaN, and Ta/TaN, produce similar lifetime statistics and failure is abrupt. Line width, however, does have a strong influence on failure time. The line width/grain size ratio ranged from 0.53 to 2.2 but does not correlate with mean time to failure (MTF). The strong dependence on interface fraction, combined with the conclusion from phase one that interface electromigration is not rate controlling, suggests another mechanism related to the interface is a controlling factor. The possibility that contamination and defects at the interface are key to this failure mode was investigated using electro-thermal fatigue (ETF). In ETF, where lines are simultaneously subjected to thermal cycling and constant current, damage caused by thermal stress is accelerated. Tests reveal that in 80 nm lines, transient failure occurs at times far below MTF in electromigration tests at higher temperatures. Failure found in ETF is clearly a result of damage growth due to thermal/mechanical stress rather than electromigration. At the stress levels created by the moderate ETF test conditions, the only place voids are likely to nucleate and grow is at pre-existing defects and impurities. In narrower lines, where smaller voids can cause catastrophic damage, defects have a greater effect on MTF. Results from this investigation suggest that impurities and defects in the Cu and at the interface, must be carefully controlled to make reliable narrow Cu interconnects.
Rojas, Jhon; Blanco, Jose L; Sanchez-Palomino, Sonsoles; Marcos, Maria A; Guardo, Alberto C; Gonzalez-Cordon, Ana; Lonca, Montserrat; Tricas, Amparo; Rodriguez, Ana; Romero, Anabel; Miro, Jose M; Mallolas, Josep; Gatell, Jose M; Plana, Montserrat; Martinez, Esteban
2018-05-09
Antiretroviral drugs contained in single tablet Atripla® have pharmacokinetic properties that could allow for longer than once-daily (OD) dosing. We hypothesized that simplifying Atripla® OD to 3-day per week would be feasible, able to maintain viral suppression and less toxic. Virologically suppressed (≥2 years) HIV+ adults on Atripla® OD, CD4 >350/mm at inclusion, and no prior documented virological failure or evidence of resistance mutations to efavirenz, tenofovir, or emtricitabine were randomized to maintain their OD regimen or to reduce it to 3 days (Mondays, Wednesdays, and Fridays) a week (3W). Primary end-point was the proportion of patients free of treatment failure (non-completer = failure) at 24 weeks. CD4 and CD8 cells, ultrasensitive HIV-1 RNA, Pittsburg Sleep Quality Index (PSQI), bone mineral density, plasma efavirenz levels, and fasting blood and urine chemistries were measured at baseline and 24 weeks. The study is registered at ClinicalTrials.gov, NCT01778413. Sixty-one patients were randomized. All patients in both arms remained free of treatment failure (estimated difference 0%; 95% confidence interval -14.1 to 14.1). Ultrasensitive plasma HIV-1 RNA below detection threshold showed no difference between arms (70% in the 3W arm vs. 71% in the OD arm, P = 0.933) at 24 weeks. Total cholesterol and femur T-score significantly increased, while PSQI, plasma efavirenz, albumin/creatinine and beta-2-microglobulin in urine significantly decreased in the 3W arm relative to OD arm. The A-TRI-WEEK study represents a proof of concept for the feasibility of three-day per week Atripla® maintenance that should be further confirmed in a larger, well-powered clinical trial.
Buck, David; Subramanyam, Rajeev; Varughese, Anna
2016-01-01
The use of a single-dose vial across multiple patients presents a risk to sterility and is against CDC guidelines. We initiated a quality improvement (QI) project to reduce the intraoperative use of single-dose vials of fentanyl across multiple patients at Cincinnati Children's Hospital Medical Center (CCHMC). The initial step of the improvement project was the development of a Key Driver Diagram. The diagram has the SMART aim of the project, key drivers inherent to the process we are trying to improve, and specific interventions targeting the key drivers. The number of patients each week receiving an IV dose of fentanyl, from a vial previously accessed for another patient was tracked in a high turnover operating room (OR). The improvement model used was based on the concept of building Plan-Do-Study-Act (PDSA) cycles. Tests of change included provider education, provision of an increased number of fentanyl vials, alternate wasting processes, and provision of single-use fentanyl syringes by the pharmacy. Prior to initiation of this project, it was common for a single fentanyl vial to be accessed for multiple patients. Our data showed an average percentage of failures of just over 50%. During the end of the project, after 7 months, the mean percentage failures had dropped to 5%. Preparation of 20 mcg single-use fentanyl syringes by pharmacy, combined with education of providers on appropriate use, was successful in reducing failures to below our goal of 25%. Appropriately sized fentanyl syringes prepared by pharmacy, education on correct use of single-dose vials, and reminders in the OR, reduced the percentage of patients receiving a dose of fentanyl from a vial previously accessed for another patient in a high-volume otolaryngology room. © 2015 John Wiley & Sons Ltd.
NASA Astrophysics Data System (ADS)
Mullin, Daniel Richard
2013-09-01
The majority of space programs whether manned or unmanned for science or exploration require that a Failure Modes Effects and Criticality Analysis (FMECA) be performed as part of their safety and reliability activities. This comes as no surprise given that FMECAs have been an integral part of the reliability engineer's toolkit since the 1950s. The reasons for performing a FMECA are well known including fleshing out system single point failures, system hazards and critical components and functions. However, in the author's ten years' experience as a space systems safety and reliability engineer, findings demonstrate that the FMECA is often performed as an afterthought, simply to meet contract deliverable requirements and is often started long after the system requirements allocation and preliminary design have been completed. There are also important qualitative and quantitative components often missing which can provide useful data to all of project stakeholders. These include; probability of occurrence, probability of detection, time to effect and time to detect and, finally, the Risk Priority Number. This is unfortunate as the FMECA is a powerful system design tool that when used effectively, can help optimize system function while minimizing the risk of failure. When performed as early as possible in conjunction with writing the top level system requirements, the FMECA can provide instant feedback on the viability of the requirements while providing a valuable sanity check early in the design process. It can indicate which areas of the system will require redundancy and which areas are inherently the most risky from the onset. Based on historical and practical examples, it is this author's contention that FMECAs are an immense source of important information for all involved stakeholders in a given project and can provide several benefits including, efficient project management with respect to cost and schedule, system engineering and requirements management, assembly integration and test (AI&T) and operations if applied early, performed to completion and updated along with system design.
Transition...One Small Step for a Young Girl, a Giant Leap for an Educational Community
ERIC Educational Resources Information Center
Terry, Shanta
2017-01-01
Can single-gender education foster student success? Can it work in a public setting? These questions have been asked many times over the past few decades. The answers have been inconclusive, with some studies saying that single-gender education truly works and others saying that it does not. The basis of the success or failure of single-gender…
Single event upset susceptibility testing of the Xilinx Virtex II FPGA
NASA Technical Reports Server (NTRS)
Yui, C.; Swift, G.; Carmichael, C.
2002-01-01
Heavy ion testing of the Xilinx Virtex IZ was conducted on the configuration, block RAM and user flip flop cells to determine their single event upset susceptibility using LETs of 1.2 to 60 MeVcm^2/mg. A software program specifically designed to count errors in the FPGA is used to reveal L1/e values and single-event-functional interrupt failures.
NASA Astrophysics Data System (ADS)
Espinosa, H. D.; Peng, B.; Moldovan, N.; Friedmann, T. A.; Xiao, X.; Mancini, D. C.; Auciello, O.; Carlisle, J.; Zorman, C. A.; Merhegany, M.
2006-08-01
In this work, the authors report the mechanical properties of three emerging materials in thin film form: single crystal silicon carbide (3C-SiC), ultrananocrystalline diamond, and hydrogen-free tetrahedral amorphous carbon. The materials are being employed in micro- and nanoelectromechanical systems. Several reports addressed some of the mechanical properties of these materials but they are based in different experimental approaches. Here, they use a single testing method, the membrane deflection experiment, to compare these materials' Young's moduli, characteristic strengths, fracture toughnesses, and theoretical strengths. Furthermore, they analyze the applicability of Weibull theory [Proc. Royal Swedish Inst. Eng. Res. 153, 1 (1939); ASME J. Appl. Mech. 18, 293 (1951)] in the prediction of these materials' failure and document the volume- or surface-initiated failure modes by fractographic analysis. The findings are of particular relevance to the selection of micro- and nanoelectromechanical systems materials for various applications of interest.
Control allocation for gimballed/fixed thrusters
NASA Astrophysics Data System (ADS)
Servidia, Pablo A.
2010-02-01
Some overactuated control systems use a control distribution law between the controller and the set of actuators, usually called control allocator. Beyond the control allocator, the configuration of actuators may be designed to be able to operate after a single point of failure, for system optimization and/or decentralization objectives. For some type of actuators, a control allocation is used even without redundancy, being a good example the design and operation of thruster configurations. In fact, as the thruster mass flow direction and magnitude only can be changed under certain limits, this must be considered in the feedback implementation. In this work, the thruster configuration design is considered in the fixed (F), single-gimbal (SG) and double-gimbal (DG) thruster cases. The minimum number of thrusters for each case is obtained and for the resulting configurations a specific control allocation is proposed using a nonlinear programming algorithm, under nominal and single-point of failure conditions.
Tensile Strength of Carbon Nanotubes Under Realistic Temperature and Strain Rate
NASA Technical Reports Server (NTRS)
Wei, Chen-Yu; Cho, Kyeong-Jae; Srivastava, Deepak; Biegel, Bryan (Technical Monitor)
2002-01-01
Strain rate and temperature dependence of the tensile strength of single-wall carbon nanotubes has been investigated with molecular dynamics simulations. The tensile failure or yield strain is found to be strongly dependent on the temperature and strain rate. A transition state theory based predictive model is developed for the tensile failure of nanotubes. Based on the parameters fitted from high-strain rate and temperature dependent molecular dynamics simulations, the model predicts that a defect free micrometer long single-wall nanotube at 300 K, stretched with a strain rate of 1%/hour, fails at about 9 plus or minus 1% tensile strain. This is in good agreement with recent experimental findings.
Mitigating Thermal Runaway Risk in Lithium Ion Batteries
NASA Technical Reports Server (NTRS)
Darcy, Eric; Jeevarajan, Judy; Russell, Samuel
2014-01-01
The JSC/NESC team has successfully demonstrated Thermal Runaway (TR) risk reduction in a lithium ion battery for human space flight by developing and implementing verifiable design features which interrupt energy transfer between adjacent electrochemical cells. Conventional lithium ion (li-Ion) batteries can fail catastrophically as a result of a single cell going into thermal runaway. Thermal runaway results when an internal component fails to separate electrode materials leading to localized heating and complete combustion of the lithium ion cell. Previously, the greatest control to minimize the probability of cell failure was individual cell screening. Combining thermal runaway propagation mitigation design features with a comprehensive screening program reduces both the probability, and the severity, of a single cell failure.
Single event induced transients in I/O devices - A characterization
NASA Technical Reports Server (NTRS)
Newberry, D. M.; Kaye, D. H.; Soli, G. A.
1990-01-01
The results of single-event upset (SEU) testing performed to evaluate the parametric transients, i.e., amplitude and duration, in several I/O devices, and the impact of these transients are discussed. The failure rate of these devices is dependent on the susceptibility of interconnected devices to the resulting transient change in the output of the I/O device. This failure rate, which is a function of the susceptibility of the interconnected device as well as the SEU response of the I/O device itself, may be significantly different from an upset rate calculated without taking these factors into account. The impact at the system level is discussed by way of an example.
Life test of the InGaAs focal plane arrays detector for space applications
NASA Astrophysics Data System (ADS)
Zhu, Xian-Liang; Zhang, Hai-Yan; Li, Xue; Huang, Zhang-Cheng; Gong, Hai-Mei
2017-08-01
The short-wavelength infrared (SWIR) InGaAs focal plane array (FPA) detector consists of infrared detector chip, readout integrated circuit (ROIC), and flip-chip bonding interconnection by Indium bump. In order to satisfy space application requirements for failure rates or Mean Time to Failure (MTTF), which can only be demonstrated with the large number of detectors manufactured, the single pixel in InGaAs FPAs was chosen as the research object in this paper. The constant-stress accelerated life tests were carried out at 70°C 80°C 90°C and100°C. The failed pixels increased gradually during more than 14000 hours at each elevated temperatures. From the random failure data the activation energy was estimated to be 0.46eV, and the average lifetime of a single pixel in InGaAs FPAs was estimated to be longer than 1E+7h at the practical operating temperature (5°C).
Technological development of high energy density capacitors. [for spacecraft power supplies
NASA Technical Reports Server (NTRS)
Parker, R. D.
1976-01-01
A study was conducted to develop cylindrical wound metallized film capacitors rated 2 micron F 500 VDC that had energy densities greater than 0.1J/g. Polysulfone (PS) and polyvinylidene (PVF2) were selected as dielectrics. Single film PS capacitors of 0.2J/g (uncased) were made of 3.75 micron material. Single film PVF2 capacitors of 0.19J/g (uncased) were made of 6.0 micron material. Corona measurements were made at room temperature, and capacitance and dissipation factor measurements were made over the ranges 25 C to 125 C and 120 Hz to 100 kHz. Nineteen of twenty PVF2 components survived a 2500 hour dc plus ac life test. Failure analyses revealed most failures occurred at wrinkles, but some edge failures were also seen. A 0.989g case was designed. When the case was combined with the PVF2 component, a finished energy density of 0.11J/g was achieved.
Operative interventions for failed heller myotomy: a single institution experience.
Pallati, Pradeep K; Mittal, Sumeet K
2011-03-01
Recurrent dysphagia and/or gastroesophageal reflux (GER) are failures of treatment after Heller myotomy for achalasia. We present our single center experience with surgical interventions for these failures. We did a retrospective analysis of a prospectively collected database. Based on preoperative symptoms and endoscopy, esophagogram, and manometry results, patients were divided into three groups to guide management. Telephone follow-up was done using a structured foregut questionnaire. Between December 2003 and June 2009, 16 patients underwent operative interventions for disabling symptoms after previous Heller myotomy. Eight patients presented primarily with recurrent dysphagia and underwent transabdominal Heller myotomy with partial fundoplication. Seven patients reported good to excellent symptom relief at mean follow-up of 42 months. One patient reported no relief and eventually required esophageal bypass with retrosternal gastric pull-up. Four patients presented with uncontrolled GER. Two patients who underwent redo partial fundoplication reported poor symptomatic outcome and one patient has since undergone short limb Roux-en-y gastric bypass (SLRNYGB) with excellent symptom relief. The other two patients underwent SLRNYGB with excellent relief at 10 months. Four patients had end stage achalasia and underwent esophageal resection with reconstruction. All reported excellent symptom relief at mean follow-up of 36 months. Transabdominal redo Heller myotomy for dysphagia has good outcomes. Redo fundoplication for GER after previous myotomy has poor results and SLRNYGB is an effective option in these patients. Esophageal resection remains an effective, albeit morbid, option for end-stage achalasia.
Hirata, Koichi; Komagata, Osamu; Itokawa, Kentaro; Yamamoto, Atsushi; Tomita, Takashi; Kasai, Shinji
2014-01-01
The voltage-sensitive sodium (Na+) channel (Vssc) is the target site of pyrethroid insecticides. Pest insects develop resistance to this class of insecticide by acquisition of one or multiple amino acid substitution(s) in this channel. In Southeast Asia, two major Vssc types confer pyrethroid resistance in the dengue mosquito vector Aedes aegypti, namely, S989P+V1016G and F1534C. We expressed several types of Vssc in Xenopus oocytes and examined the effect of amino acid substitutions in Vssc on pyrethroid susceptibilities. S989P+V1016G and F1534C haplotypes reduced the channel sensitivity to permethrin by 100- and 25-fold, respectively, while S989P+V1016G+F1534C triple mutations reduced the channel sensitivity to permethrin by 1100-fold. S989P+V1016G and F1534C haplotypes reduced the channel sensitivity to deltamethrin by 10- and 1-fold (no reduction), respectively, but S989P+V1016G+F1534C triple mutations reduced the channel sensitivity to deltamethrin by 90-fold. These results imply that pyrethroid insecticides are highly likely to lose their effectiveness against A. aegypti if such a Vssc haplotype emerges as the result of a single crossing-over event; thus, this may cause failure to control this key mosquito vector. Here, we strongly emphasize the importance of monitoring the occurrence of triple mutations in Vssc in the field population of A. aegypti. PMID:25166902
Martinez, S A; Wilson, M G; Linton, D D; Newbound, G C; Freise, K J; Lin, T-L; Clark, T P
2014-01-01
A prospective, double-blinded, positive-controlled, multicenter, noninferiority study was conducted to evaluate the safety and effectiveness of transdermal fentanyl solution (TFS) compared with oxymorphone for the control of postoperative pain in dogs. Five hundred and two (502) client-owned dogs were assigned to a single dose of TFS (2.7 mg/kg) applied 2–4 h prior to surgery or oxymorphone hydrochloride (0.22 mg/kg) administered subcutaneously 2–4 h prior to surgery and q6h through 90 h. Pain was evaluated over 4 days by blinded observers using a modified Glasgow composite pain scale, and the a priori criteria for treatment failure was a pain score ≥8 or adverse event necessitating withdrawal. Four TFS- and eight oxymorphone-treated dogs were withdrawn due to lack of pain control. Eighteen oxymorphone-treated, but no TFS-treated dogs were withdrawn due to severe adverse events. The one-sided upper 95% confidence interval of the difference between TFS and oxymorphone treatment failure rates was −5.3%. Adverse events associated with oxymorphone were greater in number and severity compared with TFS. It was concluded that a single administration of TFS was safe and noninferior to repeated injections of oxymorphone for the control of postoperative pain over 4 days at the dose rates of both formulations used in this study. PMID:24344787
Hypercalculia in savant syndrome: central executive failure?
González-Garrido, Andrés Antonio; Ruiz-Sandoval, José Luis; Gómez-Velázquez, Fabiola R; de Alba, José Luis Oropeza; Villaseñor-Cabrera, Teresa
2002-01-01
The existence of outstanding cognitive talent in mentally retarded subjects persists as a challenge to present knowledge. We report the case of a 16-year-old male patient with exceptional mental calculation abilities and moderate mental retardation. The patient was clinically evaluated. Data from standard magnetic resonance imaging (MRI) and two 99mTc-ethyl cysteine dimer (ECD)-single photon emission computer tomography (SPECT) (in resting condition and performing a mental calculation task) studies were analyzed. Main neurologic findings were brachycephalia, right-side neurologic soft signs, obsessive personality profile, low color-word interference effect in Stroop test, and diffuse increased cerebral blood flow during calculation task in 99mTc-ECD SPECT. MRI showed anatomical temporal plane inverse asymmetry. Evidence appears to support the hypothesis that savant skill is related to excessive and erroneous use of cognitive processing resources instigated by probable failure in central executive control mechanisms.
Li, Jingchao; Cao, Yunpeng; Ying, Yulong; Li, Shuying
2016-01-01
Bearing failure is one of the dominant causes of failure and breakdowns in rotating machinery, leading to huge economic loss. Aiming at the nonstationary and nonlinear characteristics of bearing vibration signals as well as the complexity of condition-indicating information distribution in the signals, a novel rolling element bearing fault diagnosis method based on multifractal theory and gray relation theory was proposed in the paper. Firstly, a generalized multifractal dimension algorithm was developed to extract the characteristic vectors of fault features from the bearing vibration signals, which can offer more meaningful and distinguishing information reflecting different bearing health status in comparison with conventional single fractal dimension. After feature extraction by multifractal dimensions, an adaptive gray relation algorithm was applied to implement an automated bearing fault pattern recognition. The experimental results show that the proposed method can identify various bearing fault types as well as severities effectively and accurately. PMID:28036329
Extending the life and recycle capability of earth storable propellant systems.
NASA Technical Reports Server (NTRS)
Schweickert, T. F.
1972-01-01
Rocket propulsion systems for reusable vehicles will be required to operate reliably for a large number of missions with a minimum of maintenance and a fast turnaround. For the space shuttle reaction control system to meet these requirements, current and prior related system failures were examined for their impact on reuse and, where warranted, component design and/or system configuration changes were defined for improving system service life. It was found necessary to change the pressurization component arrangement used on many single-use applications in order to eliminate a prevalent check valve failure mode and to incorporate redundant expulsion capability in propellant tank designs to achieve the necessary system reliability. Material flaws in pressurant and propellant tanks were noted to have a significant effect on tank cycle life. Finally, maintenance considerations dictated a modularized systems approach, allowing the system to be removed from the vehicle for service and repair at a remote site.
Li, Jingchao; Cao, Yunpeng; Ying, Yulong; Li, Shuying
2016-01-01
Bearing failure is one of the dominant causes of failure and breakdowns in rotating machinery, leading to huge economic loss. Aiming at the nonstationary and nonlinear characteristics of bearing vibration signals as well as the complexity of condition-indicating information distribution in the signals, a novel rolling element bearing fault diagnosis method based on multifractal theory and gray relation theory was proposed in the paper. Firstly, a generalized multifractal dimension algorithm was developed to extract the characteristic vectors of fault features from the bearing vibration signals, which can offer more meaningful and distinguishing information reflecting different bearing health status in comparison with conventional single fractal dimension. After feature extraction by multifractal dimensions, an adaptive gray relation algorithm was applied to implement an automated bearing fault pattern recognition. The experimental results show that the proposed method can identify various bearing fault types as well as severities effectively and accurately.
Möller, Thorsten; Schuldt, Heiko; Gerber, Andreas; Klusch, Matthias
2006-06-01
Healthcare digital libraries (DLs) increasingly make use of dedicated services to access functionality and/or data. Semantic (web) services enhance single services and facilitate compound services, thereby supporting advanced applications on top of a DL. The traditional process management approach tends to focus on process definition at build time rather than on actual service events in run time, and to anticipate failures in order to define appropriate strategies. This paper presents a novel approach where service coordination is distributed among a set of agents. A dedicated component plans compound semantic services on demand for a particular application. In failure, the planner is reinvoked to define contin- gency strategies. Finally, matchmaking is effected at runtime by choosing the appropriate service provider. These combined technologies will provide key support for highly flexible next-generation DL applications. Such technologies are under development within CASCOM.
Failure rate of single-unit restorations on posterior vital teeth: A systematic review.
Afrashtehfar, Kelvin I; Emami, Elham; Ahmadi, Motahareh; Eilayyan, Owis; Abi-Nader, Samer; Tamimi, Faleh
2017-03-01
No knowledge synthesis exists concerning when to use a direct restoration versus a complete-coverage indirect restoration in posterior vital teeth. The purpose of this systematic review was to identify the failure rate of conventional single-unit tooth-supported restorations in posterior permanent vital teeth as a function of remaining tooth structure. Four databases were searched electronically, and 8 selected journals were searched manually up to February 2015. Clinical studies of tooth-supported single-unit restorative treatments with a mean follow-up period of at least 3 years were selected. The outcome measured was the restorations' clinical or radiological failure. Following the Preferred Reporting Items for Systematic reviews and Meta-Analyses guidelines, the Cochrane Collaboration procedures for randomized control trials, the Strengthening the Reporting of Observational Studies in Epidemiology criteria for observational studies, 2 reviewers independently applied eligibility criteria, extracted data, and assessed the quality of the evidence of the included studies using the American Association of Critical Care Nurses' system. The weighted-mean group 5-year failure rates of the restorations were reported according to the type of treatment and remaining tooth structure. A metaregression model was used to assess the correlation between the number of remaining tooth walls and the weighted-mean 5-year failure rates. Five randomized controlled trials and 9 observational studies were included and their quality ranged from low to moderate. These studies included a total of 358 crowns, 4804 composite resins, and 303582 amalgams. Data obtained from the randomized controlled trials showed that, regardless of the amount of remaining tooth structure, amalgams presented better outcomes than composite resins. Furthermore, in teeth with fewer than 2 remaining walls, high-quality observational studies demonstrated that crowns were better than amalgams. A clear inverse correlation was found between the amount of remaining tooth structure and restoration failure. Insufficient high-quality data are available to support one restorative treatment or material over another for the restoration of vital posterior teeth. However, the current evidence suggests that the failure rates of treatments may depend on the amount of remaining tooth structure and types of treatment. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Repair of long-bone fractures in cats and small dogs with the Unilock mandible locking plate system.
Voss, K; Kull, M; Hässig, M; Montavon, P
2009-01-01
To retrospectively evaluate stabilisation of long-bone fractures in cats and small dogs using the Unilock system. Medical histories and radiographs of consecutive patients with long-bone fractures stabilised with the Unilock system were reviewed. Cases with follow-up radiographs taken at least four weeks postoperatively were included. Signalment of the patient, fracture localisation and type, primary fracture repair or revision surgery, single or double plating, and complications for each patient were noted. Additionally, implant size, number of screws, number of cortices engaged with screws, and number of empty holes across the fracture were evaluated in fractures where a single plate had been applied. Eighteen humeral, 18 radial, 20 femoral, and 10 tibial fractures were treated. The Unilock system was used for primary repair in 44 fractures and for revision surgery in 22 fractures. Two plates were applied in 17 fractures, and a single plate was applied in 49 fractures. Follow-up radiographs were taken four to 109 weeks postoperatively. Complications were seen in 12 animals and 13 fractures (19.7%). Fixation failure occurred in seven fractures (10.6%). Cases with a single plate that suffered fixation failure had thinner screws in relation to bone diameter than cases with double plates, and more screws in a main fragment than those without fixation failure. The Unilock system is a suitable implant for fracture fixation of long bones in cats and small dogs.
Full-Authority Fault-Tolerant Electronic Engine Control System for Variable Cycle Engines.
1982-04-01
single internally self-checked VLSI micro - processor . The selected configuration is an externally checked pair of com- mercially available...Electronic Engine Control FPMH Failures per Million Hours FTMP Fault Tolerant Multi- Processor FTSC Fault Tolerant Spaceborn Computer GRAMP Generalized...Removal * MTBR Mean Time Between Repair MTTF Mean Time to Failure xiii List of Abbreviations (continued) - NH High Pressure Rotor Speed O&S Operating
Menon, Vidthiya; Davis, Rebecca; Shackel, Nick; Espedido, Bjorn A; Beukers, Alicia G; Jensen, Slade O; van Hal, Sebastiaan J
2018-02-01
Daptomycin β-Lactam combination therapy offers "protection" against daptomycin non-susceptibility (DNS) development in Enterococcus faecium. We report failure of this strategy and the importance of source control. Mutations were detected in the LiaF and cls genes in DNS isolates. A single DNS isolate contained an unrecognized mutation, which requires confirmation. Copyright © 2017 Elsevier Inc. All rights reserved.
1981-01-01
are applied to determine what system states (usually failed states) are possible; deductive methods are applied to determine how a given system state...Similar considerations apply to the single failures of CVA, BVB and CVB and this important additional information has been displayed in the principal...way. The point "maximum tolerable failure" corresponds to the survival point of the company building the aircraft. Above that point, only intolerable
Correlation between the single, high dose of ingested baclofen and clinical symptoms.
Anand, Jacek Sein; Zając, Maciej; Waldman, Wojciech; Wojtyła, Andrzej; Biliński, Przemysław; Jaworska-Łuczak, Barbara
2017-12-23
Baclofen is a drug used mainly to treat muscle spasticity. Its overdose can lead to life-threatening clinical symptoms, including acute respiratory failure requiring mechanical ventilation. The aim of this study was to assess the prevalence of selected clinical symptoms associated with baclofen poisoning comparing to an ingested dose. 60 cases of oral baclofen poisoning were analyzed. Gender, age distribution, and correlation between the dose of ingested baclofen were studied, as well as and following clinical parameters: degree of altered consciousness, heart rate, blood pressure, presence of acute respiratory failure, duration of mechanical ventilation, and presence of psychotic symptoms. The study found statistically significant correlations between dosage of ingested baclofen and presence of acute respiratory failure, as well as duration of mechanical ventilation. No statistically significant correlations were found between the dose of ingested baclofen and presence of hypertension, bradycardia, acute psychotic symptoms, or level of consciousness disturbance. However, it was found that patients who suffered from hypertension, bradycardia, and altered mental status ingested a larger dose of baclofen. There is a statistically significant correlation between the dose of ingested baclofen and the presence of acute respiratory failure, and duration of mechanical ventilation. Patients who have taken a single dose of baclofen of 200 mg, or higher, should be managed in centres able to provide continuous monitoring of life functions. Those with a higher level of a single dose of baclofen ingestion (>500 mg), should be hospitalized in a Toxicology Unit or Intensive Care Unit able to provide airway support and mechanical ventilation.
Martinson, Melissa; Bharmi, Rupinder; Dalal, Nirav; Abraham, William T; Adamson, Philip B
2017-05-01
Haemodynamic-guided heart failure (HF) management effectively reduces decompensation events and need for hospitalizations. The economic benefit of clinical improvement requires further study. An estimate of the cost-effectiveness of haemodynamic-guided HF management was made based on observations published in the randomized, prospective single-blinded CHAMPION trial. A comprehensive analysis was performed including healthcare utilization event rates, survival, and quality of life demonstrated in the randomized portion of the trial (18 months). Markov modelling with Monte Carlo simulation was used to approximate comprehensive costs and quality-adjusted life years (QALYs) from a payer perspective. Unit costs were estimated using the Truven Health MarketScan database from April 2008 to March 2013. Over a 5-year horizon, patients in the Treatment group had average QALYs of 2.56 with a total cost of US$56 974; patients in the Control group had QALYs of 2.16 with a total cost of US$52 149. The incremental cost-effectiveness ratio (ICER) was US$12 262 per QALY. Using comprehensive cost modelling, including all anticipated costs of HF and non-HF hospitalizations, physician visits, prescription drugs, long-term care, and outpatient hospital visits over 5 years, the Treatment group had a total cost of US$212 004 and the Control group had a total cost of US$200 360. The ICER was US$29 593 per QALY. Standard economic modelling suggests that pulmonary artery pressure-guided management of HF using the CardioMEMS™ HF System is cost-effective from the US-payer perspective. This analysis provides the background for further modelling in specific country healthcare systems and cost structures. © 2016 The Authors. European Journal of Heart Failure published by John Wiley & Sons Ltd on behalf of European Society of Cardiology.