Sample records for single operator experience

  1. Electrically Driven Single Phase Thermal Management: STP-H5 EHD Experiment

    NASA Technical Reports Server (NTRS)

    Didion, Jeffrey R.

    2016-01-01

    The Electrically Driven Single Phase Thermal Management: STP-H5 iEHDS Experiment is a technology demonstration of prototype proof of concept hardware to establish the feasilibilty and long term operation of this hardware. This is a structural thermal plate that will operate continuous as part of the STP-H5 ISEM experiment for up to 18 months. This presentation discusses the design, fabrication and environmental operational paramertes of the experiment hardware.

  2. Skylab experiment performance evaluation manual. Appendix J: Experiment M555 gallium arsenide single crystal growth (MSFC)

    NASA Technical Reports Server (NTRS)

    Byers, M. S.

    1973-01-01

    Analyses for Experiment M555, Gallium Arsenide Single Crystal Growth (MSFC), to be used for evaluating the performance of the Skylab corollary experiments under preflight, inflight, and post-flight conditions are presented. Experiment contingency plan workaround procedure and malfunction analyses are presented in order to assist in making the experiment operationally successful.

  3. Characterization of pseudosingle bunch kick-and-cancel operational mode

    DOE PAGES

    Sun, C.; Robin, D. S.; Steier, C.; ...

    2015-12-18

    Pseudosingle-bunch kick-and-cancel (PSB-KAC) is a new operational mode at the Advanced Light Source of Lawrence Berkeley National Laboratory that provides full timing and repetition rate control for single x-ray pulse users while being fully transparent to other users of synchrotron radiation light. In this operational mode, a single electron bunch is periodically displaced from a main bunch train by a fast kicker magnet with a user-on-demand repetition rate, creating a single x-ray pulse to be matched to a typical laser excitation pulse rate. This operational mode can significantly improve the signal to noise ratio of single x-ray pulse experiments andmore » drastically reduce dose-induced sample damage rate. It greatly expands the capabilities of synchrotron light sources to carry out dynamics and time-of-flight experiments. In this paper, we carry out extensive characterizations of this PSB-KAC mode both numerically and experimentally. This includes the working principle of this mode, resonance conditions and beam stability, experimental setups, and diagnostic tools and measurements.« less

  4. Multiplexed single-molecule force spectroscopy using a centrifuge.

    PubMed

    Yang, Darren; Ward, Andrew; Halvorsen, Ken; Wong, Wesley P

    2016-03-17

    We present a miniature centrifuge force microscope (CFM) that repurposes a benchtop centrifuge for high-throughput single-molecule experiments with high-resolution particle tracking, a large force range, temperature control and simple push-button operation. Incorporating DNA nanoswitches to enable repeated interrogation by force of single molecular pairs, we demonstrate increased throughput, reliability and the ability to characterize population heterogeneity. We perform spatiotemporally multiplexed experiments to collect 1,863 bond rupture statistics from 538 traceable molecular pairs in a single experiment, and show that 2 populations of DNA zippers can be distinguished using per-molecule statistics to reduce noise.

  5. Multiplexed single-molecule force spectroscopy using a centrifuge

    PubMed Central

    Yang, Darren; Ward, Andrew; Halvorsen, Ken; Wong, Wesley P.

    2016-01-01

    We present a miniature centrifuge force microscope (CFM) that repurposes a benchtop centrifuge for high-throughput single-molecule experiments with high-resolution particle tracking, a large force range, temperature control and simple push-button operation. Incorporating DNA nanoswitches to enable repeated interrogation by force of single molecular pairs, we demonstrate increased throughput, reliability and the ability to characterize population heterogeneity. We perform spatiotemporally multiplexed experiments to collect 1,863 bond rupture statistics from 538 traceable molecular pairs in a single experiment, and show that 2 populations of DNA zippers can be distinguished using per-molecule statistics to reduce noise. PMID:26984516

  6. The Heteronuclear Single-Quantum Correlation (HSQC) Experiment: Vectors versus Product Operators

    ERIC Educational Resources Information Center

    de la Vega-Herna´ndez, Karen; Antuch, Manuel

    2015-01-01

    A vectorial representation of the full sequence of events occurring during the 2D-NMR heteronuclear single-quantum correlation (HSQC) experiment is presented. The proposed vectorial representation conveys an understanding of the magnetization evolution during the HSQC pulse sequence for those who have little or no quantum mechanical background.…

  7. High intensity single bunch operation with heavy periodic transient beam loading in wide band rf cavities

    NASA Astrophysics Data System (ADS)

    Tamura, Fumihiko; Hotchi, Hideaki; Schnase, Alexander; Yoshii, Masahito; Yamamoto, Masanobu; Ohmori, Chihiro; Nomura, Masahiro; Toda, Makoto; Shimada, Taihei; Hasegawa, Katsushi; Hara, Keigo

    2015-09-01

    The rapid cycling synchrotron (RCS) in the Japan Proton Accelerator Research Complex (J-PARC) was originally designed to accelerate two high intensity bunches, while some of neutron experiments in the materials and life science experimental facility and a muon experiment using main ring beams require a single bunch operation mode, in which one of the two rf buckets is filled and the other is empty. The beam intensity in the single bunch operation has been limited by longitudinal beam losses due to the rf bucket distortions by the wake voltage of the odd harmonics (h =1 ,3 ,5 ) in the wide band magnetic alloy cavities. We installed an additional rf feedforward system to compensate the wake voltages of the odd harmonics (h =1 ,3 ,5 ). The additional system has a similar structure as the existing feedforward system for the even harmonics (h =2 ,4 ,6 ). We describe the function of the feedforward system for the odd harmonics, the commissioning methodology, and the commissioning results. The longitudinal beam losses during the single bunch acceleration disappeared with feedforward for the odd harmonics. We also confirmed that the beam quality in the single bunch acceleration are similar to that of the normal operation with two bunches. Thus, high intensity single bunch acceleration at the intensity of 2.3 ×1013 protons per bunch has been achieved in the J-PARC RCS. This article is a follow-up of our previous article, Phys. Rev. ST Accel. Beams 14, 051004 (2011). The feedforward system extension for single bunch operation was successful.

  8. Operating single quantum emitters with a compact Stirling cryocooler

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schlehahn, A.; Krüger, L.; Gschrey, M.

    2015-01-15

    The development of an easy-to-operate light source emitting single photons has become a major driving force in the emerging field of quantum information technology. Here, we report on the application of a compact and user-friendly Stirling cryocooler in the field of nanophotonics. The Stirling cryocooler is used to operate a single quantum emitter constituted of a semiconductor quantum dot (QD) at a base temperature below 30 K. Proper vibration decoupling of the cryocooler and its surrounding enables free-space micro-photoluminescence spectroscopy to identify and analyze different charge-carrier states within a single quantum dot. As an exemplary application in quantum optics, wemore » perform a Hanbury-Brown and Twiss experiment demonstrating a strong suppression of multi-photon emission events with g{sup (2)}(0) < 0.04 from this Stirling-cooled single quantum emitter under continuous wave excitation. Comparative experiments performed on the same quantum dot in a liquid helium (LHe)-flow cryostat show almost identical values of g{sup (2)}(0) for both configurations at a given temperature. The results of this proof of principle experiment demonstrate that low-vibration Stirling cryocoolers that have so far been considered exotic to the field of nanophotonics are an attractive alternative to expensive closed-cycle cryostats or LHe-flow cryostats, which could pave the way for the development of high-quality table-top non-classical light sources.« less

  9. Operating single quantum emitters with a compact Stirling cryocooler.

    PubMed

    Schlehahn, A; Krüger, L; Gschrey, M; Schulze, J-H; Rodt, S; Strittmatter, A; Heindel, T; Reitzenstein, S

    2015-01-01

    The development of an easy-to-operate light source emitting single photons has become a major driving force in the emerging field of quantum information technology. Here, we report on the application of a compact and user-friendly Stirling cryocooler in the field of nanophotonics. The Stirling cryocooler is used to operate a single quantum emitter constituted of a semiconductor quantum dot (QD) at a base temperature below 30 K. Proper vibration decoupling of the cryocooler and its surrounding enables free-space micro-photoluminescence spectroscopy to identify and analyze different charge-carrier states within a single quantum dot. As an exemplary application in quantum optics, we perform a Hanbury-Brown and Twiss experiment demonstrating a strong suppression of multi-photon emission events with g((2))(0) < 0.04 from this Stirling-cooled single quantum emitter under continuous wave excitation. Comparative experiments performed on the same quantum dot in a liquid helium (LHe)-flow cryostat show almost identical values of g((2))(0) for both configurations at a given temperature. The results of this proof of principle experiment demonstrate that low-vibration Stirling cryocoolers that have so far been considered exotic to the field of nanophotonics are an attractive alternative to expensive closed-cycle cryostats or LHe-flow cryostats, which could pave the way for the development of high-quality table-top non-classical light sources.

  10. Single-frequency oscillation of thin-disk lasers due to phase-matched pumping.

    PubMed

    Vorholt, Christian; Wittrock, Ulrich

    2017-09-04

    We present a novel pump concept that should lead to single-frequency operation of thin-disk lasers without the need for etalons or other spectral filters. The single-frequency operation is due to matching the standing wave pattern of partially coherent pump light to the standing wave pattern of the laser light inside the disk. The output power and the optical efficiency of our novel pump concept are compared with conventional pumping. The feasibility of our pump concept was shown in previous experiments.

  11. Three dimensional CFD modeling and experimental validation of a single chamber solid oxide fuel cell fed by methane

    NASA Astrophysics Data System (ADS)

    Nguyen, H. T.; Le, M. V.; Nguyen, T. A.; Nguyen, T. A. N.

    2017-06-01

    The solid oxide fuel cell is one of the promising technologies for future energy demand. Solid oxide fuel cell operated in the single-chamber mode exhibits several advantages over conventional single oxide fuel cell due to the simplified, compact, sealing-free cell structure. There are some studies on simulating the behavior of this type of fuel cell but they mainly focus on the 2D model. In the present study, a three-dimensional numerical model of a single chamber solid oxide fuel cell (SOFC) is reported and solved using COMSOL Multiphysics software. Experiments of a planar button solid oxide fuel cell were used to verify the simulation results. The system is fed by methane and oxygen and operated at 700°C. The cathode is LSCF6482, the anode is GDC-Ni, the electrolyte is LDM and the operating pressure is 1 atm. There was a good agreement between the cell temperature and current voltage estimated from the model and measured from the experiment. The results indicate that the model is applicable for the single chamber solid oxide fuel cell and it can provide a basic for the design, scale up of single chamber solid oxide fuel cell system.

  12. Laparoscopic single port surgery in children using Triport: our early experience.

    PubMed

    de Armas, Ismael A Salas; Garcia, Isabella; Pimpalwar, Ashwin

    2011-09-01

    Laparoscopy has become the gold standard technique for appendectomy and cholecystectomy. With the emergence of newer laparoscopic instruments which are roticulating and provide 7 degrees of freedom it is now possible to perform these operations through a single umbilical incision rather than the standard 3-4 incisions and thus lead to more desirable cosmetic results and less postoperative pain. The newer reticulating telescopes provide excellent exposure of the operating field and allow the operations to proceed routinely. Recently, ports [Triports (Olympus surgery)/SILS ports] especially designed for single incision laparoscopic surgery (SILS) have been developed. We herein describe our experience with laparoscopic single port appendectomies and cholecystectomies in children using the Triport. This is a retrospective cohort study of children who underwent single incision laparoscopic surgery between May 2009 and August 2010 at Texas Children's Hospital and Ben Taub General Hospital in Houston Texas by a single surgeon. Charts were reviewed for demographics, type of procedure, operative time, early or late complications, outcome and cosmetic results. Fifty-four patients underwent SILS. A total of 50 appendectomies (early or perforated) and 4 cholecystectomies were performed using this new minimally invasive approach. The average operative time for SILS/LESS appendectomy was 54 min with a range between 25 and 205 min, while operative time for SILS cholecystectomy was 156 min with a range of 75-196 min. Only small percentage (4%) of appendectomies (mostly complicated) were converted to standard laparoscopy, but none were converted to open procedure. All patients were followed up in the clinic after 3-4 weeks. No complications were noted and all patients had excellent cosmetic results. Parents were extremely satisfied with the cosmetic results. SILS/LESS is a safe, minimally invasive approach for appendectomy and cholecystectomy in children. This new approach is performed in an acceptable operative time with good outcomes and great cosmetic result.

  13. Spacelab operations planning. [ground handling, launch, flight and experiments

    NASA Technical Reports Server (NTRS)

    Lee, T. J.

    1976-01-01

    The paper reviews NASA planning in the fields of ground, launch and flight operations and experiment integration to effectively operate Spacelab. Payload mission planning is discussed taking consideration of orbital analysis and the mission of a multiuser payload which may be either single or multidiscipline. Payload analytical integration - as active process of analyses to ensure that the experiment payload is compatible to the mission objectives and profile ground and flight operations and that the resource demands upon Spacelab can be satisfied - is considered. Software integration is touched upon and the major integration levels in ground operational processing of Spacelab and its experimental payloads are examined. Flight operations, encompassing the operation of the Space Transportation System and the payload, are discussed as are the initial Spacelab missions. Charts and diagrams are presented illustrating the various planning areas.

  14. Feasibility and Learning Curve of Robotic Laparoendoscopic Single-Site Surgery in Gynecology.

    PubMed

    Buckley de Meritens, Alexandre; Kim, Julia; Dinkelspiel, Helen; Chapman-Davis, Eloise; Caputo, Thomas; Holcomb, Kevin M

    2017-02-01

    Single-site laparoscopy has proven to be a desirable option for patients undergoing gynecologic surgery, with some studies indicating improved cosmesis and less perioperative pain compared with standard approaches. This study describes the safety and feasibility of a novel robotic laparoendoscopic single-site surgery (R-LESS) platform as it is incorporated into a surgeon's practice with extensive multiport robotic surgical experience but limited LESS experience. We reviewed 83 women undergoing R-LESS by a single surgeon from September 2013 through August 2015. Operative times (total operative time, console time, docking time) were collected prospectively for the first 53 cases, and total operative time was collected retrospectively for the next 30 cases. Clinical parameters, including age, estimated blood loss, body mass index (BMI), prior abdominal surgeries, conversion to laparotomy, procedure type, uterine weight, length of hospital stay, and complications, were retrospectively collected from medical charts. Eighty-two of 83 surgeries were completed successfully with a single incision. One surgery was converted to multiport robotics for para-aortic lymph node dissection. Twelve surgeries were performed for cancer (ovary 1, uterus 8, and cervix 3). Eight patients underwent pelvic lymph node biopsy. The median total operative time for hysterectomies was 128 minutes (range, 60-275). After the first 13 hysterectomies the total operative time and the console time decreased significantly from 165.3 to 131.1 minutes (p = .032) and from 84.9 to 57.1 minutes (p = .028), respectively. Mean docking time halved from 7.8 minutes to 3.4 minutes comparing the first 10 cases to the last 10 cases. Surgical times were longer with larger BMIs, but the console time decreased with experience regardless of BMI. The mean uterine weight was 164 g (range, 30-460). Complications included 2 umbilical hernias (2.4%) and 1 conversion to multiport. In conclusion, R-LESS is a feasible and safe surgical platform for gynecologic procedures. A small number of cases are needed to significantly improve operative times when it is introduced on a surgeon's practice with limited experience in LESS but familiar with robotic surgery. Further study is needed to investigate the cost, benefits, and long-term outcomes of R-LESS. Published by Elsevier Inc.

  15. AMO EXPRESS: A Command and Control Experiment for Crew Autonomy Onboard the International Space Station

    NASA Technical Reports Server (NTRS)

    Cornelius, Randy; Frank, Jeremy; Garner, Larry; Haddock, Angie; Stetson, Howard; Wang, Lui

    2015-01-01

    The Autonomous Mission Operations project is investigating crew autonomy capabilities and tools for deep space missions. Team members at Ames Research Center, Johnson Space Center and Marshall Space Flight Center are using their experience with ISS Payload operations and TIMELINER to: move earth based command and control assets to on-board for crew access; safely merge core and payload command procedures; give the crew single action intelligent operations; and investigate crew interface requirements.

  16. First Results from the Cornell COBRA Accelerator for Light Ion ICF Research

    NASA Astrophysics Data System (ADS)

    Lindholm, F.; Krastelev, E. G.; Greenly, J. B.; Kusse, B. R.

    1996-11-01

    COBRA, the Cornell Beam Research Accelerator, is a four-stage linear induction adder based on the Sandia National Laboratories SABRE accelerator design. The full 4 × 1 MV, 200 kA, 40 ns COBRA was completed in June 1996, after a year of initial operation with a single stage. Accelerator operation will be described, and first experimental results of power coupling and ion beam generation using a closely-coupled (short MITL) applied-B extraction ion diode load will be presented. A diagnostic package for beam optics including local microdivergence and aiming measurements is being developed, and results from both the single-stage experiments and new experiments on the full accelerator will be presented. A 20 ns, 15% voltage precursor to the main pulse resulting from coupling through the nonlinear magnetization characteristic of the Metglas^circR core at high magnetization rate was seen in the single-cell experiments. This mechanism will be discussed and its consequences on the full accelerator will be investigated.

  17. Interference experiment with asymmetric double slit by using 1.2-MV field emission transmission electron microscope.

    PubMed

    Harada, Ken; Akashi, Tetsuya; Niitsu, Kodai; Shimada, Keiko; Ono, Yoshimasa A; Shindo, Daisuke; Shinada, Hiroyuki; Mori, Shigeo

    2018-01-17

    Advanced electron microscopy technologies have made it possible to perform precise double-slit interference experiments. We used a 1.2-MV field emission electron microscope providing coherent electron waves and a direct detection camera system enabling single-electron detections at a sub-second exposure time. We developed a method to perform the interference experiment by using an asymmetric double-slit fabricated by a focused ion beam instrument and by operating the microscope under a "pre-Fraunhofer" condition, different from the Fraunhofer condition of conventional double-slit experiments. Here, pre-Fraunhofer condition means that each single-slit observation was performed under the Fraunhofer condition, while the double-slit observations were performed under the Fresnel condition. The interference experiments with each single slit and with the asymmetric double slit were carried out under two different electron dose conditions: high-dose for calculation of electron probability distribution and low-dose for each single electron distribution. Finally, we exemplified the distribution of single electrons by color-coding according to the above three types of experiments as a composite image.

  18. X-rays only when you want them: optimized pump–probe experiments using pseudo-single-bunch operation

    PubMed Central

    Hertlein, M. P.; Scholl, A.; Cordones, A. A.; Lee, J. H.; Engelhorn, K.; Glover, T. E.; Barbrel, B.; Sun, C.; Steier, C.; Portmann, G.; Robin, D. S.

    2015-01-01

    Laser pump–X-ray probe experiments require control over the X-ray pulse pattern and timing. Here, the first use of pseudo-single-bunch mode at the Advanced Light Source in picosecond time-resolved X-ray absorption experiments on solutions and solids is reported. In this mode the X-ray repetition rate is fully adjustable from single shot to 500 kHz, allowing it to be matched to typical laser excitation pulse rates. Suppressing undesired X-ray pulses considerably reduces detector noise and improves signal to noise in time-resolved experiments. In addition, dose-induced sample damage is considerably reduced, easing experimental setup and allowing the investigation of less robust samples. Single-shot X-ray exposures of a streak camera detector using a conventional non-gated charge-coupled device (CCD) camera are also demonstrated. PMID:25931090

  19. X-rays only when you want them: Optimized pump–probe experiments using pseudo-single-bunch operation

    DOE PAGES

    Hertlein, M. P.; Scholl, A.; Cordones, A. A.; ...

    2015-04-02

    Laser pump–X-ray probe experiments require control over the X-ray pulse pattern and timing. Here, the first use of pseudo-single-bunch mode at the Advanced Light Source in picosecond time-resolved X-ray absorption experiments on solutions and solids is reported. In this mode the X-ray repetition rate is fully adjustable from single shot to 500 kHz, allowing it to be matched to typical laser excitation pulse rates. Suppressing undesired X-ray pulses considerably reduces detector noise and improves signal to noise in time-resolved experiments. In addition, dose-induced sample damage is considerably reduced, easing experimental setup and allowing the investigation of less robust samples. Single-shotmore » X-ray exposures of a streak camera detector using a conventional non-gated charge-coupled device (CCD) camera are also demonstrated.« less

  20. Cryogenic motion performances of a piezoelectric single crystal micromotor

    NASA Astrophysics Data System (ADS)

    Li, Xiaotian; Wu, Yuting; Chen, Zhijiang; Wei, Xiaoyong; Luo, Haosu; Dong, Shuxiang

    2014-04-01

    This study investigates the cryogenic performances of a millimeter-size piezoelectric ultrasonic linear micromotor. The piezoelectric vibrator of the micromotor is made of Pb(In1/2Nb1/2)O3 -Pb(Mg1/3Nb2/3)-PbTiO3 single crystal and operated in first-bending wobbling mode. Experiments show that the piezoelectric single crystal micromotor works effectively even at extremely low temperature of -175 °C, although its resonance peaks vary with temperature significantly. This work confirms the feasibility of cryogenic operation of the piezo-micromotor, which is meaningful for aerospace or superconducting microwave application.

  1. An Assessment of Reduced Crew and Single Pilot Operations in Commercial Transport Aircraft Operations

    NASA Technical Reports Server (NTRS)

    Bailey, Randall E.; Kramer, Lynda J.; Kennedy, Kellie D.; Stephens, Chad L.; Etherington, Timothy J.

    2017-01-01

    Future reduced crew operations or even single pilot operations for commercial airline and on-demand mobility applications are an active area of research. These changes would reduce the human element and thus, threaten the precept that "a well-trained and well-qualified pilot is the critical center point of aircraft systems safety and an integral safety component of the entire commercial aviation system." NASA recently completed a pilot-in-the-loop high fidelity motion simulation study in partnership with the Federal Aviation Administration (FAA) attempting to quantify the pilot's contribution to flight safety during normal flight and in response to aircraft system failures. Crew complement was used as the experiment independent variable in a between-subjects design. These data show significant increases in workload for single pilot operations, compared to two-crew, with subjective assessments of safety and performance being significantly degraded as well. Nonetheless, in all cases, the pilots were able to overcome the failure mode effects in all crew configurations. These data reflect current-day flight deck equipage and help identify the technologies that may improve two-crew operations and/or possibly enable future reduced crew and/or single pilot operations.

  2. Investigations of SBS and Laser Gain Competition in High-Power Phase Modulated Fiber Amplifiers (Postprint)

    DTIC Science & Technology

    2014-02-26

    through RF filtering . Subsequently, this modulated signal is used in a cutback experiment with a passive fiber . Studies describing enhancement factors...to filter out higher order modes [3]. However, in order to maintain single-mode (diffraction limited) operation, conventional step-index fiber core...Letters 36, 2686-2688 (2011). [3] J. P. Koplaw, D. Kliner, and L. Goldberg, “Single-mode operation of a coiled multimode fiber amplifier,” Optics Letters

  3. Multiple acquisitions via sequential transfer of orphan spin polarization (MAeSTOSO): How far can we push residual spin polarization in solid-state NMR?

    NASA Astrophysics Data System (ADS)

    Gopinath, T.; Veglia, Gianluigi

    2016-06-01

    Conventional multidimensional magic angle spinning (MAS) solid-state NMR (ssNMR) experiments detect the signal arising from the decay of a single coherence transfer pathway (FID), resulting in one spectrum per acquisition time. Recently, we introduced two new strategies, namely DUMAS (DUal acquisition Magic Angle Spinning) and MEIOSIS (Multiple ExperIments via Orphan SpIn operatorS), that enable the simultaneous acquisitions of multidimensional ssNMR experiments using multiple coherence transfer pathways. Here, we combined the main elements of DUMAS and MEIOSIS to harness both orphan spin operators and residual polarization and increase the number of simultaneous acquisitions. We show that it is possible to acquire up to eight two-dimensional experiments using four acquisition periods per each scan. This new suite of pulse sequences, called MAeSTOSO for Multiple Acquisitions via Sequential Transfer of Orphan Spin pOlarization, relies on residual polarization of both 13C and 15N pathways and combines low- and high-sensitivity experiments into a single pulse sequence using one receiver and commercial ssNMR probes. The acquisition of multiple experiments does not affect the sensitivity of the main experiment; rather it recovers the lost coherences that are discarded, resulting in a significant gain in experimental time. Both merits and limitations of this approach are discussed.

  4. Advances in dust cyclone research

    USDA-ARS?s Scientific Manuscript database

    Dust cyclones reduce particulate emissions but their operation consumes electrical energy. Response surface methodology was used to compare two strategies to reduce energy costs without increasing emissions. Cyclones of a standard design (1D3D) were operated singly and in series, as was an ‘Experi...

  5. Influence of operator's experience on root canal shaping ability with a rotary nickel-titanium single-file reciprocating motion system.

    PubMed

    Muñoz, Estefanía; Forner, Leopoldo; Llena, Carmen

    2014-04-01

    The aim of this study was to evaluate the influence of the operator's experience on the shaping of double-curvature simulated root canals with a nickel-titanium single-file reciprocating motion system. Sixty double-curvature root canals simulated in methacrylate blocks were prepared by 10 students without any experience in endodontics and by 10 professionals who had studied endodontics at the postgraduate level. The Reciproc-VDW system's R25 file was used in the root canal preparation. The blocks were photographed before and after the instrumentation, and the time of instrumentation was also evaluated. Changes in root canal dimensions were analyzed in 6 positions. Significant differences (P < .05) were found in the apical transport of the first root canal curvature, with a larger percentage of increase of the root canal occurring in the novice group than in the expert one, as well as in the canal deviation at the beginning of the curvatures, whereas no significant results were obtained in the growth rate of the canal area. There was difference in the time of instrumentation, with 3.76 minutes observed in the novice group, as opposed to 2.05 minutes in the expert group. The use of the single-file reciprocating motion system Reciproc is not seen to be influenced by the operator's experience regarding the increase of the canal area. Previous training and the need to acquire experience are important in the use of this system, in spite of its apparent simplicity. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  6. Single-Port Surgery: Laboratory Experience with the daVinci Single-Site Platform

    PubMed Central

    Haber, Georges-Pascal; Kaouk, Jihad; Kroh, Matthew; Chalikonda, Sricharan; Falcone, Tommaso

    2011-01-01

    Background and Objectives: The purpose of this study was to evaluate the feasibility and validity of a dedicated da Vinci single-port platform in the porcine model in the performance of gynecologic surgery. Methods: This pilot study was conducted in 4 female pigs. All pigs had a general anesthetic and were placed in the supine and flank position. A 2-cm umbilical incision was made, through which a robotic single-port device was placed and pneumoperitoneum obtained. A data set was collected for each procedure and included port placement time, docking time, operative time, blood loss, and complications. Operative times were compared between cases and procedures by use of the Student t test. Results: A total of 28 surgical procedures (8 oophorectomies, 4 hysterectomies, 8 pelvic lymph node dissections, 4 aorto-caval nodal dissections, 2 bladder repairs, 1 uterine horn anastomosis, and 1 radical cystectomy) were performed. There was no statistically significant difference in operating times for symmetrical procedures among animals (P=0.3215). Conclusions: This animal study demonstrates that single-port robotic surgery using a dedicated single-site platform allows performing technically challenging procedures within acceptable operative times and without complications or insertion of additional trocars. PMID:21902962

  7. Pre-Study Walkthrough with a Commercial Pilot for a Preliminary Single Pilot Operations Experiment

    NASA Technical Reports Server (NTRS)

    O'Connor-Dreher, Ryan; Roberts, Z.; Ziccardi, J.; Vu, K-P. L.; Strybel, T.; Koteskey, Robert William; Lachter, Joel B.; Vi Dao, Quang; Johnson, Walter W.; Battiste, V.

    2013-01-01

    The number of crew members in commercial flights has decreased to two members, down from the five-member crew required 50 years ago. One question of interest is whether the crew should be reduced to one pilot. In order to determine the critical factors involved in safely transitioning to a single pilot, research must examine whether any performance deficits arise with the loss of a crew member. With a concrete understanding of the cognitive and behavioral role of a co-pilot, aeronautical technologies and procedures can be developed that make up for the removal of the second aircrew member. The current project describes a pre-study walkthrough process that can be used to help in the development of scenarios for testing future concepts and technologies for single pilot operations. Qualitative information regarding the tasks performed by the pilots can be extracted with this technique and adapted for future investigations of single pilot operations.

  8. Learning curve of single port laparoscopic cholecystectomy determined using the non-linear ordinary least squares method based on a non-linear regression model: An analysis of 150 consecutive patients.

    PubMed

    Han, Hyung Joon; Choi, Sae Byeol; Park, Man Sik; Lee, Jin Suk; Kim, Wan Bae; Song, Tae Jin; Choi, Sang Yong

    2011-07-01

    Single port laparoscopic surgery has come to the forefront of minimally invasive surgery. For those familiar with conventional techniques, however, this type of operation demands a different type of eye/hand coordination and involves unfamiliar working instruments. Herein, the authors describe the learning curve and the clinical outcomes of single port laparoscopic cholecystectomy for 150 consecutive patients with benign gallbladder disease. All patients underwent single port laparoscopic cholecystectomy using a homemade glove port by one of five operators with different levels of experiences of laparoscopic surgery. The learning curve for each operator was fitted using the non-linear ordinary least squares method based on a non-linear regression model. Mean operating time was 77.6 ± 28.5 min. Fourteen patients (6.0%) were converted to conventional laparoscopic cholecystectomy. Complications occurred in 15 patients (10.0%), as follows: bile duct injury (n = 2), surgical site infection (n = 8), seroma (n = 2), and wound pain (n = 3). One operator achieved a learning curve plateau at 61.4 min per procedure after 8.5 cases and his time improved by 95.3 min as compared with initial operation time. Younger surgeons showed significant decreases in mean operation time and achieved stable mean operation times. In particular, younger surgeons showed significant decreases in operation times after 20 cases. Experienced laparoscopic surgeons can safely perform single port laparoscopic cholecystectomy using conventional or angled laparoscopic instruments. The present study shows that an operator can overcome the single port laparoscopic cholecystectomy learning curve in about eight cases.

  9. Tomography of a displacement photon counter for discrimination of single-rail optical qubits

    NASA Astrophysics Data System (ADS)

    Izumi, Shuro; Neergaard-Nielsen, Jonas S.; Andersen, Ulrik L.

    2018-04-01

    We investigate the performance of a detection strategy composed of a displacement operation and a photon counter, which is known as a beneficial tool in optical coherent communications, to the quantum state discrimination of the two superpositions of vacuum and single photon states corresponding to the {\\hat{σ }}x eigenstates in the single-rail encoding of photonic qubits. We experimentally characterize the detection strategy in vacuum-single photon two-dimensional space using quantum detector tomography and evaluate the achievable discrimination error probability from the reconstructed measurement operators. We furthermore derive the minimum error rate obtainable with Gaussian transformations and homodyne detection. Our proof-of-principle experiment shows that the proposed scheme can achieve a discrimination error surpassing homodyne detection.

  10. Rapid quantification of soilborne pathogen communities in wheat-based long-term field experiments

    USDA-ARS?s Scientific Manuscript database

    Traditional isolation and quantification of inoculum density is difficult for most soilborne pathogens. Quantitative PCR methods have been developed to rapidly identify and quantify many of these pathogens using a single DNA extract from soil. Rainfed experiments operated continuously for up to 84 y...

  11. Tele-Manipulation with Two Asymmetric Slaves: Two Operators Perform Better Than One.

    PubMed

    van Oosterhout, Jeroen; Heemskerk, Cock J M; de Baar, Marco R; van der Helm, Frans C T; Abbink, David A

    2018-01-01

    Certain tele-manipulation tasks require manipulation by two asymmetric slaves, for example, a crane for hoisting and a dexterous robotic arm for fine manipulation. It is unclear how to best design human-in-the-loop control over two asymmetric slaves. The goal of this paper is to quantitatively compare the standard approach of two co-operating operators that each control a single subtask, to a single operator performing bi-manual control over the two subtasks, and a uni-manual control approach. In a human factors experiment, participants performed a heavy load maneuvering and mounting task using a vertical crane and a robotic arm. We hypothesize that bi-manual control yields worse task performance and control activity compared to co-operation, because of conflicting spatial and temporal constraints. Literature suggests that uni-manual operators should perform better than co-operation, as co-operators critically depend on each other's actions. However, other literature provides evidence that individual operators have limited capabilities in controlling asymmetric axes of two dynamic systems. The results show that the two co-operators perform the maneuvering and mounting task faster than either bi- or uni-manual operators. Compared to co-operators, uni-manual operators required more control activity for the vertical crane and less for the robotic arm. In conclusion, this study suggests that when controlling two asymmetric slaves, a co-operating pair of operators performs better than a single operator.

  12. Laboratory for Computer Science Progress Report 19, 1 July 1981-30 June 1982.

    DTIC Science & Technology

    1984-05-01

    Multiprocessor Architectures 202 4. TRIX Operating System 209 5. VLSI Tools 212 ’SYSTEMATIC PROGRAM DEVELOPMENT, 221 1. Introduction 222 2. Specification...exploring distributed operating systems and the architecture of single-user powerful computers that are interconnected by communication networks. The...to now. In particular, we expect to experiment with languages, operating systems , and applications that establish the feasibility of distributed

  13. Control system design for the large space systems technology reference platform

    NASA Technical Reports Server (NTRS)

    Edmunds, R. S.

    1982-01-01

    Structural models and classical frequency domain control system designs were developed for the large space systems technology (LSST) reference platform which consists of a central bus structure, solar panels, and platform arms on which a variety of experiments may be mounted. It is shown that operation of multiple independently articulated payloads on a single platform presents major problems when subarc second pointing stability is required. Experiment compatibility will be an important operational consideration for systems of this type.

  14. Analysis of deterministic swapping of photonic and atomic states through single-photon Raman interaction

    NASA Astrophysics Data System (ADS)

    Rosenblum, Serge; Borne, Adrien; Dayan, Barak

    2017-03-01

    The long-standing goal of deterministic quantum interactions between single photons and single atoms was recently realized in various experiments. Among these, an appealing demonstration relied on single-photon Raman interaction (SPRINT) in a three-level atom coupled to a single-mode waveguide. In essence, the interference-based process of SPRINT deterministically swaps the qubits encoded in a single photon and a single atom, without the need for additional control pulses. It can also be harnessed to construct passive entangling quantum gates, and can therefore form the basis for scalable quantum networks in which communication between the nodes is carried out only by single-photon pulses. Here we present an analytical and numerical study of SPRINT, characterizing its limitations and defining parameters for its optimal operation. Specifically, we study the effect of losses, imperfect polarization, and the presence of multiple excited states. In all cases we discuss strategies for restoring the operation of SPRINT.

  15. Recent high-speed ballistics experiments at ORNL

    NASA Astrophysics Data System (ADS)

    Combs, S. K.; Gouge, M. J.; Baylor, L. R.; Fisher, P. W.; Foster, C. A.; Foust, C. R.; Milora, S. L.; Qualls, A. L.

    Oak Ridge National Laboratory (ORNL) has been developing pellet injectors for plasma fueling experiments on magnetic confinement devices for almost 20 years. With these devices, pellets (1 to 8 mm in diameter) composed of hydrogen isotopes are formed (at temperatures less than 20 K) and typically accelerated to speeds of (approximately) 1.0 to 2.0 km/s for injection into plasmas of experimental fusion devices. A variety of pellet injector designs have been developed at ORNL, including repeating pneumatic injectors (single- and multiple-barrel light gas guns) that can inject up to hundreds of pellets for long-pulse plasma operation. The repeating pneumatic injectors are of particular importance because long-pulse fueling is required for present large experimental fusion devices, with steady-state operation the objective for future fusion reactors. In this paper, recent advancements in the development of repeating pneumatic injectors are described, including (1) a small-bore (1.8-mm), high-firing-rate (10-Hz) version of a single-stage light gas gun; (2) a repeating single-stage light gas gun for 8-mm-diam tritium pellets; (3) a repeating two-stage light gas gun for operation at higher pellet velocities; and (4) a steady-state hydrogen extruder feed system.

  16. Recent high-speed ballistics experiments at ORNL

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Combs, S.K.; Gouge, M.J.; Baylor, L.R.

    1994-12-31

    Oak Ridge National Laboratory (ORNL) has been developing pellet injectors for plasma fueling experiments on magnetic confinement devices for almost 20 years. With these devices, pellets (1 to 8 mm in diameter) composed of hydrogen isotopes are formed (at temperatures <20 K) and typically accelerated to speeds of {approximately} 1.0 to 2.0 km/s for injection into plasmas of experimental fusion devices. A variety of pellet injector designs have been developed at ORNL, including repeating pneumatic injectors (single- and multiple-barrel light gas guns) that can inject up to hundreds of pellets for long-pulse plasma operation. The repeating pneumatic injectors are ofmore » particular importance because long-pulse fueling is required for present large experimental fusion devices, with steady-state operation the objective for future fusion reactors. In this paper, recent advancements in the development of repeating pneumatic injectors are described, including (1) a small-bore (1.8-mm), high-firing-rate (10-Hz) version of a single-stage light gas gun; (2) a repeating single-stage light gas gun for 8-mm-diam tritium pellets; (3) a repeating two-stage light gas gun for operation at higher pellet velocities; and (4) a steady-state hydrogen extruder feed system.« less

  17. Highly angular dependent high-contrast grating mirror and its application for transverse-mode control of VCSELs

    NASA Astrophysics Data System (ADS)

    Inoue, Shunya; Kashino, Junichi; Matsutani, Akihiro; Ohtsuki, Hideo; Miyashita, Takahiro; Koyama, Fumio

    2014-09-01

    We report on the design and fabrication of a highly angular dependent high contrast grating (HCG) mirror. The modeling and experiment on amorphous-Si/SiO2 HCG clearly show the large angular dependence of reflectivity, which enables single transverse-mode operations of large-area VCSELs. We fabricate 980 nm VCSELs with the angular dependent HCG functioning as a spatial frequency filter. We obtained the single transverse mode operation of the fabricated device in contrast to conventional VCSELs with semiconductor multilayer mirrors.

  18. Urgent and Elective Robotic Single-Site Cholecystectomy: Analysis and Learning Curve of 150 Consecutive Cases.

    PubMed

    Kubat, Eric; Hansen, Nathan; Nguyen, Huy; Wren, Sherry M; Eisenberg, Dan

    2016-03-01

    The use of robotic single-site cholecystectomy has increased exponentially. There are few reports describing the safety, efficacy, and operative learning curve of robotic single-site cholecystectomy either in the community setting or with nonelective surgery. We performed a retrospective review of a prospective database of our initial experience with robotic single-site cholecystectomy. Demographics and perioperative outcomes were evaluated for both urgent and elective cholecystectomy. Cumulative sum analysis was performed to determine the surgeon's learning curve. One hundred fifty patients underwent robotic single-site cholecystectomy. Seventy-four (49.3%) patients underwent urgent robotic single-site cholecystectomy, and 76 (50.7%) underwent elective robotic single-site cholecystectomy. Mean total operative time for robotic single-site cholecystectomy was 83.3 ± 2.7 minutes. Mean operative time for the urgent cohort was significantly longer than for the elective cohort (95.0 ± 4.4 versus 71.9 ± 2.6 minutes; P < .001). There was one conversion in the urgent cohort and none in the elective cohort. There was one bile duct injury (0.7%) in the urgent cohort. Perioperative complications occurred in 8.7% of patients, and most consisted of superficial surgical-site infections. There were no incisional hernias detected. The surgeon's learning curve, inclusive of urgent and elective cases, was 48 operations. Robotic single-site cholecystectomy can be performed safely and effectively in both elective and urgent cholecystectomy with a reasonable learning curve and acceptable perioperative outcomes.

  19. High Voltage TAL Performance

    NASA Technical Reports Server (NTRS)

    Jacobson, David T.; Jankovsky, Robert S.; Rawlin, Vincent K.; Manzella, David H.

    2001-01-01

    The performance of a two-stage, anode layer Hall thruster was evaluated. Experiments were conducted in single and two-stage configurations. In single-stage configuration, the thruster was operated with discharge voltages ranging from 300 to 1700 V. Discharge specific impulses ranged from 1630 to 4140 sec. Thruster investigations were conducted with input power ranging from 1 to 8.7 kW, corresponding to power throttling of nearly 9: 1. An extensive two-stage performance map was generated. Data taken with total voltage (sum of discharge and accelerating voltage) constant revealed a decrease in thruster efficiency as the discharge voltage was increased. Anode specific impulse values were comparable in the single and two-stage configurations showing no strong advantage for two-stage operation.

  20. New operator assistance features in the CMS Run Control System

    NASA Astrophysics Data System (ADS)

    Andre, J.-M.; Behrens, U.; Branson, J.; Brummer, P.; Chaze, O.; Cittolin, S.; Contescu, C.; Craigs, B. G.; Darlea, G.-L.; Deldicque, C.; Demiragli, Z.; Dobson, M.; Doualot, N.; Erhan, S.; Fulcher, J. R.; Gigi, D.; Gładki, M.; Glege, F.; Gomez-Ceballos, G.; Hegeman, J.; Holzner, A.; Janulis, M.; Jimenez-Estupiñán, R.; Masetti, L.; Meijers, F.; Meschi, E.; Mommsen, R. K.; Morovic, S.; O'Dell, V.; Orsini, L.; Paus, C.; Petrova, P.; Pieri, M.; Racz, A.; Reis, T.; Sakulin, H.; Schwick, C.; Simelevicius, D.; Vougioukas, M.; Zejdl, P.

    2017-10-01

    During Run-1 of the LHC, many operational procedures have been automated in the run control system of the Compact Muon Solenoid (CMS) experiment. When detector high voltages are ramped up or down or upon certain beam mode changes of the LHC, the DAQ system is automatically partially reconfigured with new parameters. Certain types of errors such as errors caused by single-event upsets may trigger an automatic recovery procedure. Furthermore, the top-level control node continuously performs cross-checks to detect sub-system actions becoming necessary because of changes in configuration keys, changes in the set of included front-end drivers or because of potential clock instabilities. The operator is guided to perform the necessary actions through graphical indicators displayed next to the relevant command buttons in the user interface. Through these indicators, consistent configuration of CMS is ensured. However, manually following the indicators can still be inefficient at times. A new assistant to the operator has therefore been developed that can automatically perform all the necessary actions in a streamlined order. If additional problems arise, the new assistant tries to automatically recover from these. With the new assistant, a run can be started from any state of the sub-systems with a single click. An ongoing run may be recovered with a single click, once the appropriate recovery action has been selected. We review the automation features of CMS Run Control and discuss the new assistant in detail including first operational experience.

  1. New Operator Assistance Features in the CMS Run Control System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Andre, J.M.; et al.

    During Run-1 of the LHC, many operational procedures have been automated in the run control system of the Compact Muon Solenoid (CMS) experiment. When detector high voltages are ramped up or down or upon certain beam mode changes of the LHC, the DAQ system is automatically partially reconfigured with new parameters. Certain types of errors such as errors caused by single-event upsets may trigger an automatic recovery procedure. Furthermore, the top-level control node continuously performs cross-checks to detect sub-system actions becoming necessary because of changes in configuration keys, changes in the set of included front-end drivers or because of potentialmore » clock instabilities. The operator is guided to perform the necessary actions through graphical indicators displayed next to the relevant command buttons in the user interface. Through these indicators, consistent configuration of CMS is ensured. However, manually following the indicators can still be inefficient at times. A new assistant to the operator has therefore been developed that can automatically perform all the necessary actions in a streamlined order. If additional problems arise, the new assistant tries to automatically recover from these. With the new assistant, a run can be started from any state of the sub-systems with a single click. An ongoing run may be recovered with a single click, once the appropriate recovery action has been selected. We review the automation features of CMS Run Control and discuss the new assistant in detail including first operational experience.« less

  2. The Naturalistic Flight Deck System: An Integrated System Concept for Improved Single-Pilot Operations

    NASA Technical Reports Server (NTRS)

    Schutte, Paul C.; Goodrich, Kenneth H.; Cox, David E.; Jackson, Bruce; Palmer, Michael T.; Pope, Alan T.; Schlecht, Robin W.; Tedjojuwono, Ken K.; Trujillo, Anna C.; Williams, Ralph A.; hide

    2007-01-01

    This paper reviews current and emerging operational experiences, technologies, and human-machine interaction theories to develop an integrated flight system concept designed to increase the safety, reliability, and performance of single-pilot operations in an increasingly accommodating but stringent national airspace system. This concept, know as the Naturalistic Flight Deck (NFD), uses a form of human-centered automation known as complementary-automation (or complemation) to structure the relationship between the human operator and the aircraft as independent, collaborative agents having complimentary capabilities. The human provides commonsense knowledge, general intelligence, and creative thinking, while the machine contributes specialized intelligence and control, extreme vigilance, resistance to fatigue, and encyclopedic memory. To support the development of the NFD, an initial Concept of Operations has been created and selected normal and non-normal scenarios are presented in this document.

  3. Risk of surgical site infection in paediatric herniotomies without any prophylactic antibiotics: A preliminary experience.

    PubMed

    Vaze, Dhananjay; Samujh, Ram; Narasimha Rao, Katragadda Lakshmi

    2014-01-01

    Different studies underline the use of pre-operative antibiotic prophylaxis in clean surgeries like herniotomy and inguinal orchiopexy. But, the meta-analyses do not recommend nor discard the use of prophylactic pre-operative antibiotics. The scarcity of controlled clinical trials in paediatric population further vitiates the matter. This study assessed the difference in the rate of early post-operative wound infection cases in children who received single dose of pre-operative antibiotics and children who did not receive antibiotics after inguinal herniotomy and orchiopexy. This randomised prospective study was conducted in Paediatric Surgery department of PGIMER Chandigarh. Out of 251 patients, 112 patients were randomised to the case group and 139 were ascribed to the control group. The patients in control group were given a standard regimen of single dose of intravenous antibiotic at the time of induction followed by 3-4 days of oral antibiotic. Case group patients underwent the surgical procedure in similar manner with no antibiotic either at the time of induction or post-operatively. The incidence of surgical site infection in case group was 3.73 % and that in control group was 2.22%. The observed difference in the incidence of surgical site infection was statistically insignificant (P value = 0.7027). The overall infection rate in case and control group was 2.89%. Our preliminary experience suggests that there is no statistically significant difference in the proportion of early post-operative wound infection between the patients who received single dose of pre-operative antibiotics and the patients who received no antibiotics after inguinal herniotomy and orchiopexy. The risk of surgical site infection in paediatric heriotomies does not increase even if the child's weight is less than his/her expected weight for age.

  4. Laparoendoscopic Single-Site Cholecystectomy: First Experiences with a New Standardized Technique Replicating the Four-Port Technique.

    PubMed

    Morales-Conde, Salvador; Cañete-Gómez, Jesús; Gómez, Virginia; Socas Macías, María; Moreno, Antonio Barranco; Del Agua, Isaias Alarcón; Ruíz, Francisco Javier Padillo

    2016-10-01

    After reports on laparoendoscopic single-site (LESS) cholecystectomy, concerns have been raised over the level of difficulty and a potential increase in complications when moving away from conventional gold standard multiport laparoscopy due to incomplete exposure and larger umbilical incisions. With continued development of technique and technology, it has now become possible to fully replicate this gold standard procedure through an LESS approach. First experiences with the newly developed technique and instrument are reported. Fifteen patients presenting with cholelithiasis without signs of inflammation were operated using all surgical steps considered appropriate for the conventional four-port laparoscopic approach, but applied through a single access device. Operation-centered outcomes are presented. There were no peri- or postoperative complications. Mean operating time was 32.3 minutes. No conversion to regular laparoscopy was required. The critical view of safety was achieved in all cases. Mean skin incision length was 2.2 cm. The application of a standardized technique combined with the use of a four-port LESS device allows us to perform LESS cholecystectomy, giving us a correct exposure of the structures and without increasing the mean operating time combining previously reported advantages of LESS. A universal trait of any new technique should be safety and reproducibility. This will enhance its applicability by large number of surgeons and to large number of patients requiring cholecystectomy.

  5. Initial experience of single-port laparoscopic surgery for sigmoid colon cancer.

    PubMed

    Park, Sun Jin; Lee, Kil Yeon; Kang, Byung Mo; Choi, Sung Il; Lee, Suk Hwan

    2013-03-01

    Single-port laparoscopic surgery has attracted attention in the field of minimally invasive colorectal surgery. We hypothesized that an experienced laparoscopic surgeon could perform single-port surgery for colon cancer eligible for conventional laparoscopic anterior resection. Our aim was to analyze our initial experience and immediate surgical outcomes of single-port anterior resection. A total of 37 consecutive patients with presumed sigmoid colonic cancer underwent single-port anterior resection with standard laparoscopic instruments between May 2009 and June 2010. Each operation was performed by one of two experienced colorectal surgeons. A cohort of patients who had undergone conventional laparoscopic surgery (CLS) for the same duration a year earlier (August 2007 to September 2008) was used as a historical control. Patient demographics and perioperative outcomes were analyzed and compared with those of CLS. There were no significant differences in mean estimated blood loss, mean length of the resection margin, or morbidity between the two groups, but operative time for the single-port group was significantly shorter (118 ± 41 vs. 140 ± 42 min; p = 0.017). Single-port laparoscopic surgery was successfully performed in 78.4% (29/37) of the patients treated in 2010, and CLS was successfully completed in all of the patients treated the previous year (p = 0.000). The main causes of single-port surgery failure were adhesion and tumor location. Single-port anterior resection is a feasible and safe procedure with immediate outcomes comparable to those of conventional laparoscopy. Further studies are required to determine the feasibility of single-port surgery for colonic tumors outside the sigmoid colon and the long-term outcome.

  6. Single center, single operator comparative study of the effectiveness of electrohydraulic and electromagnetic lithotripters in the management of 10- to 20-mm single upper urinary tract calculi.

    PubMed

    Jamshaid, Anila; Ather, M Hammad; Hussain, Ghazi; Khawaja, Karim B

    2008-11-01

    This study compared the efficacy and safety profile of electrohydraulic (EH) and electromagnetic (EM) lithotriptors in the treatment of 10- to 20-mm renal and proximal ureteric stones at a single center and by a single operator. Between January 2001 and December 2006, we sequentially treated patients meeting study inclusion criteria with MPL 9000 Dornier EH for the first 3 years, followed by the EM Siemens Modularis shockwave lithotripsy (SWL) unit. A single operator performed all SWL treatments under the supervision of an admitting urologist. We analyzed the demographic features and stone- and treatment-related parameters including complications for both groups. In each group, the stone-free rate and efficiency quotient was determined at 1-3 months. Of 274 patients, we sequentially treated 112 using the EH lithotriptor, and 162 the EM lithotriptor. The pre-SWL patients and stone-related parameters were similar in the two groups, except for diagnostic imaging modalities. The mean number of SWL sessions, need for ancillary procedure, retreatment rate, stone location, stone-free rate, and efficiency quotient were not significantly different between groups. The mean number of shockwaves required for complete fragmentation was 2977 and 6044 (P < .000) for the EH and EM groups, respectively. Single center, single operator experience with two types of lithotriptor indicated that both are equally efficacious, with similar safety profiles. The only significant difference was that the EH lithotriptor required fewer shockwaves for fragmentation.

  7. Managing operational documentation in the ALICE Detector Control System

    NASA Astrophysics Data System (ADS)

    Lechman, M.; Augustinus, A.; Bond, P.; Chochula, P.; Kurepin, A.; Pinazza, O.; Rosinsky, P.

    2012-12-01

    ALICE (A Large Ion Collider Experiment) is one of the big LHC (Large Hadron Collider) experiments at CERN in Geneve, Switzerland. The experiment is composed of 18 sub-detectors controlled by an integrated Detector Control System (DCS) that is implemented using the commercial SCADA package PVSSII. The DCS includes over 1200 network devices, over 1,000,000 monitored parameters and numerous custom made software components that are prepared by over 100 developers from all around the world. This complex system is controlled by a single operator via a central user interface. One of his/her main tasks is the recovery of anomalies and errors that may occur during operation. Therefore, clear, complete and easily accessible documentation is essential to guide the shifter through the expert interfaces of different subsystems. This paper describes the idea of the management of the operational documentation in ALICE using a generic repository that is built on a relational database and is integrated with the control system. The experience gained and the conclusions drawn from the project are also presented.

  8. Methodology Developed for Modeling the Fatigue Crack Growth Behavior of Single-Crystal, Nickel-Base Superalloys

    NASA Technical Reports Server (NTRS)

    1996-01-01

    Because of their superior high-temperature properties, gas generator turbine airfoils made of single-crystal, nickel-base superalloys are fast becoming the standard equipment on today's advanced, high-performance aerospace engines. The increased temperature capabilities of these airfoils has allowed for a significant increase in the operating temperatures in turbine sections, resulting in superior propulsion performance and greater efficiencies. However, the previously developed methodologies for life-prediction models are based on experience with polycrystalline alloys and may not be applicable to single-crystal alloys under certain operating conditions. One of the main areas where behavior differences between single-crystal and polycrystalline alloys are readily apparent is subcritical fatigue crack growth (FCG). The NASA Lewis Research Center's work in this area enables accurate prediction of the subcritical fatigue crack growth behavior in single-crystal, nickel-based superalloys at elevated temperatures.

  9. Experimental Investigation of a Multi-Cycle Single-Tube Pulse Detonation Rocket Engine with a Coaxial Rotary Valve

    NASA Astrophysics Data System (ADS)

    Matsuoka, Ken; Esumi, Motoki; Ikeguchi, Ken Bryan; Kasahara, Jiro; Matsuo, Akiko; Funaki, Ikkoh

    We developed a novel coaxial rotary valve for a multi-tube PDE. Since this single valve can supply three different gases (fuel, oxidizer and purge gas) into a combustor, the unification of the valve systems for three different gases is possible by using our newly designed valve. A PDRE system can be simple and lightweight by using this valve, and thus its thrust-weight ratio can be increased. We proposed the design of a multi-tube rotary-valved PDRE system by this rotary valve. Moreover, in preparation for a multi-tube rotary-valved PDRE, we carried out the multi-cycle operation experiment by the single-tube rotary-valved PDRE system. The combustion wave velocity was measured to confirm the operation of the PDRE system. Deflagration-to-detonation transition (DDT) was confirmed and DDT distance decreased under the condition of high operation frequency. In addition, a maximum operation frequency was 159 Hz.

  10. Contexts and Control Operations Used in Accessing List-Specific, Generalized, and Semantic Memories

    ERIC Educational Resources Information Center

    Humphreys, Michael S.; Murray, Krista L.; Maguire, Angela M.

    2009-01-01

    The human ability to focus memory retrieval operations on a particular list, episode or memory structure has not been fully appreciated or documented. In Experiment 1-3, we make it increasingly difficult for participants to switch between a less recent list (multiple study opportunities), and a more recent list (single study opportunity). Task…

  11. Dynamic analysis and numerical experiments for balancing of the continuous single-disc and single-span rotor-bearing system

    NASA Astrophysics Data System (ADS)

    Wang, Aiming; Cheng, Xiaohan; Meng, Guoying; Xia, Yun; Wo, Lei; Wang, Ziyi

    2017-03-01

    Identification of rotor unbalance is critical for normal operation of rotating machinery. The single-disc and single-span rotor, as the most fundamental rotor-bearing system, has attracted research attention over a long time. In this paper, the continuous single-disc and single-span rotor is modeled as a homogeneous and elastic Euler-Bernoulli beam, and the forces applied by bearings and disc on the shaft are considered as point forces. A fourth-order non-homogeneous partial differential equation set with homogeneous boundary condition is solved for analytical solution, which expresses the unbalance response as a function of position, rotor unbalance and the stiffness and damping coefficients of bearings. Based on this analytical method, a novel Measurement Point Vector Method (MPVM) is proposed to identify rotor unbalance while operating. Only a measured unbalance response registered for four selected cross-sections of the rotor-shaft under steady-state operating conditions is needed when using the method. Numerical simulation shows that the detection error of the proposed method is very small when measurement error is negligible. The proposed method provides an efficient way for rotor balancing without test runs and external excitations.

  12. High power VCSEL devices for atomic clock applications

    NASA Astrophysics Data System (ADS)

    Watkins, L. S.; Ghosh, C.; Seurin, J.-F.; Zhou, D.; Xu, G.; Xu, B.; Miglo, A.

    2015-09-01

    We are developing VCSEL technology producing >100mW in single frequency at wavelengths 780nm, 795nm and 850nm. Small aperture VCSELs with few mW output have found major applications in atomic clock experiments. Using an external cavity three-mirror configuration we have been able to operate larger aperture VCSELs and obtain >70mW power in single frequency operation. The VCSEL has been mounted in a fiber pigtailed package with the external mirror mounted on a shear piezo. The package incorporates a miniature Rb cell locker to lock the VCSEL wavelength. This VCSEL operates in single frequency and is tuned by a combination of piezo actuator, temperature and current. Mode-hop free tuning over >30GHz frequency span is obtained. The VCSEL has been locked to the Rb D2 line and feedback control used to obtain line-widths of <100kHz.

  13. The DZERO Level 3 Data Acquisition System

    NASA Astrophysics Data System (ADS)

    Angstadt, R.; Brooijmans, G.; Chapin, D.; Clements, M.; Cutts, D.; Haas, A.; Hauser, R.; Johnson, M.; Kulyavtsev, A.; Mattingly, S. E. K.; Mulders, M.; Padley, P.; Petravick, D.; Rechenmacher, R.; Snyder, S.; Watts, G.

    2004-06-01

    The DZERO experiment began RunII datataking operation at Fermilab in spring 2001. The physics program of the experiment requires the Level 3 data acquisition (DAQ) system system to handle average event sizes of 250 kilobytes at a rate of 1 kHz. The system routes and transfers event fragments of approximately 1-20 kilobytes from 63 VME crate sources to any of approximately 100 processing nodes. It is built upon a Cisco 6509 Ethernet switch, standard PCs, and commodity VME single board computers (SBCs). The system has been in full operation since spring 2002.

  14. Comparative study of clinical and radiological outcomes of a zero-profile device concerning reduced postoperative Dysphagia after single level anterior cervical discectomy and fusion.

    PubMed

    Son, Doo Kyung; Son, Dong Wuk; Kim, Ho Sang; Sung, Soon Ki; Lee, Sang Weon; Song, Geun Sung

    2014-08-01

    This study analyzed clinical and radiological outcomes of a zero-profile anchored spacer (Zero-P) and conventional cage-plate (CCP) for single level anterior cervical discectomy and fusion (ACDF) to compare the incidence and difference of postoperative dysphagia with both devices. We retrospectively reviewed our experiences of single level ACDF with the CCP and Zero-P. From January 2011 to December 2013, 48 patients who had single level herniated intervertebral disc were operated on using ACDF, with CCP in 27 patients and Zero-P in 21 patients. Patients who received more than double-level ACDF or combined circumferential fusion were excluded. Age, operation time, estimated blood loss (EBL), pre-operative modified Japanese Orthopaedic Association (mJOA) scores, post-operative mJOA scores, achieved mJOA scores and recovery rate of mJOA scores were assessed. Prevertebral soft tissue thickness and postoperative dysphagia were analyzed on the day of surgery, and 2 weeks and 6 months postoperatively. The Zero-P group showed same or favorable clinical and radiological outcomes compared with the CCP group. Postoperative dysphagia was significantly low in the Zero-P group. Application of Zero-P may achieve favorable outcomes and reduce postoperative dysphagia in single level ACDF.

  15. Tunable Er-doped fiber ring laser with single longitudinal mode operation based on Rayleigh backscattering in single mode fiber.

    PubMed

    Yin, Guolu; Saxena, Bhavaye; Bao, Xiaoyi

    2011-12-19

    A tunable and single longitudinal mode Er-doped fiber ring laser (SLM-EDFRL) is proposed and demonstrated based on Rayleigh backscattering (RBS) in single mode fiber-28e (SMF-28e). Theory and experimental study on formation of SLM from normal multi-mode ring laser is demonstrated. The RBS feedback in 660 m SMF-28e is the key to ensure SLM laser oscillation. This tunable SLM laser can be tuned over 1549.7-1550.18 nm with a linewidth of 2.5-3.0 kHz and a side mode suppression ratio (SMSR) of ~72 dB for electrical signal power. The tuning range is determined by the bandpass filter and gain medium used in the experiment. The laser is able to operate at S+C+L band.

  16. Learning curve evaluation using cumulative summation analysis-a clinical example of pediatric robot-assisted laparoscopic pyeloplasty.

    PubMed

    Cundy, Thomas P; Gattas, Nicholas E; White, Alan D; Najmaldin, Azad S

    2015-08-01

    The cumulative summation (CUSUM) method for learning curve analysis remains under-utilized in the surgical literature in general, and is described in only a small number of publications within the field of pediatric surgery. This study introduces the CUSUM analysis technique and applies it to evaluate the learning curve for pediatric robot-assisted laparoscopic pyeloplasty (RP). Clinical data were prospectively recorded for consecutive pediatric RP cases performed by a single-surgeon. CUSUM charts and tests were generated for set-up time, docking time, console time, operating time, total operating room time, and postoperative complications. Conversions and avoidable operating room delay were separately evaluated with respect to case experience. Comparisons between case experience and time-based outcomes were assessed using the Student's t-test and ANOVA for bi-phasic and multi-phasic learning curves respectively. Comparison between case experience and complication frequency was assessed using the Kruskal-Wallis test. A total of 90 RP cases were evaluated. The learning curve transitioned beyond the learning phase at cases 10, 15, 42, 57, and 58 for set-up time, docking time, console time, operating time, and total operating room time respectively. All comparisons of mean operating times between the learning phase and subsequent phases were statistically significant (P=<0.001-0.01). No significant difference was observed between case experience and frequency of post-operative complications (P=0.125), although the CUSUM chart demonstrated a directional change in slope for the last 12 cases in which there were high proportions of re-do cases and patients <6 months of age. The CUSUM method has a valuable role for learning curve evaluation and outcome quality monitoring. In applying this statistical technique to the largest reported single surgeon series of pediatric RP, we demonstrate numerous distinctly shaped learning curves and well-defined learning phase transition points. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. Recognizing the Operating Hand and the Hand-Changing Process for User Interface Adjustment on Smartphones †

    PubMed Central

    Guo, Hansong; Huang, He; Huang, Liusheng; Sun, Yu-E

    2016-01-01

    As the size of smartphone touchscreens has become larger and larger in recent years, operability with a single hand is getting worse, especially for female users. We envision that user experience can be significantly improved if smartphones are able to recognize the current operating hand, detect the hand-changing process and then adjust the user interfaces subsequently. In this paper, we proposed, implemented and evaluated two novel systems. The first one leverages the user-generated touchscreen traces to recognize the current operating hand, and the second one utilizes the accelerometer and gyroscope data of all kinds of activities in the user’s daily life to detect the hand-changing process. These two systems are based on two supervised classifiers constructed from a series of refined touchscreen trace, accelerometer and gyroscope features. As opposed to existing solutions that all require users to select the current operating hand or confirm the hand-changing process manually, our systems follow much more convenient and practical methods and allow users to change the operating hand frequently without any harm to the user experience. We conduct extensive experiments on Samsung Galaxy S4 smartphones, and the evaluation results demonstrate that our proposed systems can recognize the current operating hand and detect the hand-changing process with 94.1% and 93.9% precision and 94.1% and 93.7% True Positive Rates (TPR) respectively, when deciding with a single touchscreen trace or accelerometer-gyroscope data segment, and the False Positive Rates (FPR) are as low as 2.6% and 0.7% accordingly. These two systems can either work completely independently and achieve pretty high accuracies or work jointly to further improve the recognition accuracy. PMID:27556461

  18. Recognizing the Operating Hand and the Hand-Changing Process for User Interface Adjustment on Smartphones.

    PubMed

    Guo, Hansong; Huang, He; Huang, Liusheng; Sun, Yu-E

    2016-08-20

    As the size of smartphone touchscreens has become larger and larger in recent years, operability with a single hand is getting worse, especially for female users. We envision that user experience can be significantly improved if smartphones are able to recognize the current operating hand, detect the hand-changing process and then adjust the user interfaces subsequently. In this paper, we proposed, implemented and evaluated two novel systems. The first one leverages the user-generated touchscreen traces to recognize the current operating hand, and the second one utilizes the accelerometer and gyroscope data of all kinds of activities in the user's daily life to detect the hand-changing process. These two systems are based on two supervised classifiers constructed from a series of refined touchscreen trace, accelerometer and gyroscope features. As opposed to existing solutions that all require users to select the current operating hand or confirm the hand-changing process manually, our systems follow much more convenient and practical methods and allow users to change the operating hand frequently without any harm to the user experience. We conduct extensive experiments on Samsung Galaxy S4 smartphones, and the evaluation results demonstrate that our proposed systems can recognize the current operating hand and detect the hand-changing process with 94.1% and 93.9% precision and 94.1% and 93.7% True Positive Rates (TPR) respectively, when deciding with a single touchscreen trace or accelerometer-gyroscope data segment, and the False Positive Rates (FPR) are as low as 2.6% and 0.7% accordingly. These two systems can either work completely independently and achieve pretty high accuracies or work jointly to further improve the recognition accuracy.

  19. The scanning tunnelling microscope as an operative tool: doing physics and chemistry with single atoms and molecules.

    PubMed

    Rieder, Karl-Heinz; Meyer, Gerhard; Hla, Saw-Wai; Moresco, Francesca; Braun, Kai F; Morgenstern, Karina; Repp, Jascha; Foelsch, Stefan; Bartels, Ludwig

    2004-06-15

    The scanning tunnelling microscope, initially invented to image surfaces down to the atomic scale, has been further developed in the last few years to an operative tool, with which atoms and molecules can be manipulated at will at low substrate temperatures in different manners to create and investigate artificial structures, whose properties can be investigated employing spectroscopic dI/dV measurements. The tunnelling current can be used to selectively break chemical bonds, but also to induce chemical association. These possibilities give rise to startling new opportunities for physical and chemical experiments on the single atom and single molecule level. Here we provide a short overview on recent results obtained with these techniques.

  20. Impact of Fluidic Chevrons on Supersonic Jet Noise

    NASA Technical Reports Server (NTRS)

    Henderson, Brenda; Norum, Thomas

    2007-01-01

    The impact of fluidic chevrons on broadband shock noise and mixing noise for single stream and coannular jets was investigated. Air was injected into the core flow of a bypass ratio 5 nozzle system using a core fluidic chevron nozzle. For the single stream experiments, the fan stream was operated at the wind tunnel conditions and the core stream was operated at supersonic speeds. For the dual stream experiments, the fan stream was operated at supersonic speeds and the core stream was varied between subsonic and supersonic conditions. For the single stream jet at nozzle pressure ratio (NPR) below 2.0, increasing the injection pressure of the fluidic chevron increased high frequency noise at observation angles upstream of the nozzle exit and decreased mixing noise near the peak jet noise angle. When the NPR increased to a point where broadband shock noise dominated the acoustic spectra at upstream observation angles, the fluidic chevrons significantly decreased this noise. For dual stream jets, the fluidic chevrons reduced broadband shock noise levels when the fan NPR was below 2.3, but had little or no impact on shock noise with further increases in fan pressure. For all fan stream conditions investigated, the fluidic chevron became more effective at reducing mixing noise near the peak jet noise angle as the core pressure increased.

  1. Single subject controlled experiments in aphasia: The science and the state of the science

    PubMed Central

    Thompson, Cynthia K.

    2007-01-01

    This paper discusses the use of single subject controlled experimental designs for investigating the effect of treatment for aphasia. A brief historical perspective is presented, followed by discussions of the advantages and disadvantages of single subject and group approaches, the basic requirements of single subject experimental research, and crucial considerations in design selection. In the final sections, results of reviews of published single subject controlled experiments are discussed, with emphasis on internal validity issues, the number of participants enrolled in published studies, operational specification of the dependent and independent variables, and reliability of measurement. Learning outcomes As a result of reading this paper, the participant will: (1) understand the mechanisms required for demonstration of internal and external validity using single subject controlled experimental designs, (2) become familiar with the basic requirements of single subject controlled experimental research, (3) understand the types of single subject controlled experimental designs that are the most appropriate for studying the effects of treatment for aphasia, and (4) become familiar with trends in the published aphasia treatment literature in which single subject controlled experimental designs have been used. PMID:16635494

  2. Two-gigawatt burst-mode operation of the intense microwave prototype (IMP) free-electron laser (FEL) for the microwave tokamak experiment (MTX)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Felker, B.; Allen, S.; Bell, H.

    1993-10-06

    The MTX explored the plasma heating effects of 140 GHz microwaves from both Gyrotrons and from the IMP FEL wiggler. The Gyrotron was long pulse length (0.5 seconds maximum) and the FEL produced short-pulse length, high-peak power, single and burst modes of 140 GHZ microwaves. Full-power operations of the IMP FEL wiggler were commenced in April of 1992 and continued into October of 1992. The Experimental Test Accelerator H (ETA-II) provided a 50-nanosecond, 6-MeV, 2--3 kAmp electron beam that was introduced co-linear into the IMP FEL with a 140 GHz Gyrotron master oscillator (MO). The FEL was able to amplifymore » the MO signal from approximately 7 kW to peaks consistently in the range of 1--2 GW. This microwave pulse was transmitted into the MTX and allowed the exploration of the linear and non-linear effects of short pulse, intense power in the MTX plasma. Single pulses were used to explore and gain operating experience in the parameter space of the IMP FEL, and finally evaluate transmission and absorption in the MTX. Single-pulse operations were repeatable. After the MTX was shut down burst-mode operations were successful at 2 kHz. This paper will describe the IMP FEL, Microwave Transmission System to MTX, the diagnostics used for calorimetric measurements, and the operations of the entire Microwave system. A discussion of correlated and uncorrelated errors that affect FEL performance will be made Linear and non-linear absorption data of the microwaves in the MTX plasma will be presented.« less

  3. Investigation of Single Stage Axial Fans

    NASA Technical Reports Server (NTRS)

    Ruden, P.

    1944-01-01

    The following investigations are connected with experiments on fans carried out by the author in the Gouttingen Aerodynamic Laboratory within the framework of the preliminary experiments for the new Gouttingen wind-tunnel project. A fan rotor was developed which had very high efficiency at the design point corresponding to moderate pressure and which, in addition, could operate at a proportionally high pressure, rise. To establish the determining operating factors the author carried out extensive theoretical investigation in Hannover. In this it was necessary, to depart from the usual assumption of vanishing radial velocities. The calculations were substantially lightened by the introduction of diagrams. The, first part of the.report describes the theoretical investigations; the second, the experiments carried out at Gouttingen.

  4. Tunable single frequency fiber laser based on FP-LD injection locking.

    PubMed

    Zhang, Aiqin; Feng, Xinhuan; Wan, Minggui; Li, Zhaohui; Guan, Bai-ou

    2013-05-20

    We propose and demonstrate a tunable single frequency fiber laser based on Fabry Pérot laser diode (FP-LD) injection locking. The single frequency operation principle is based on the fact that the output from a FP-LD injection locked by a multi-longitudinal-mode (MLM) light can have fewer longitudinal-modes number and narrower linewidth. By inserting a FP-LD in a fiber ring laser cavity, single frequency operation can be possibly achieved when stable laser oscillation established after many roundtrips through the FP-LD. Wavelength switchable single frequency lasing can be achieved by adjusting the tunable optical filter (TOF) in the cavity to coincide with different mode of the FP-LD. By adjustment of the drive current of the FP-LD, the lasing modes would shift and wavelength tunable operation can be obtained. In experiment, a wavelength tunable range of 32.4 nm has been obtained by adjustment of the drive current of the FP-LD and a tunable filter in the ring cavity. Each wavelength has a side-mode suppression ratio (SMSR) of at least 41 dB and a linewidth of about 13 kHz.

  5. Abdominal Emergencies in Patients with Stage IV Melanoma: The Role of Surgery: A Single-centre Experience.

    PubMed

    Mantas, Dimitrios; Damaskos, Christos; Garmpis, Nikolaos; Dimitroulis, Dimitrios; Garmpi, Anna; Gogas, Helen

    2018-06-01

    Metastatic melanoma is an aggressive disease with poor prognosis. Melanoma can potentially involve any organ. In this article, we report on a single-centre experience in emergency surgery for M1c melanoma. Twenty-eight consecutive patients with M1c melanoma underwent surgical exploration due to abdominal emergencies. Pre-operative computed tomography confirmed the diagnosis and the location of the affected site. Pre-operative lactate dehydrogenase serum levels and post-operative histopathology findings were recorded. Intestinal obstruction was the most frequent intraoperative finding (75%). The ileum was most frequently affected (28.6%). Multifocal disease and extra-gastrointestinal tract metastases were present in 25% of cases each. Lactate dehydrogenase serum level was increased in 75% of the patients. Most patients underwent an enterectomy. Curative surgery for stage IV melanoma remains debatable, but surgery for patients presenting with abdominal emergencies appears to improve both survival rate and prognosis. Combined novel therapies and surgical resection is currently being studied with promising results. Copyright© 2018, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.

  6. Analysis of the learning curve for peroral endoscopic myotomy for esophageal achalasia: Single-center, two-operator experience.

    PubMed

    Lv, Houning; Zhao, Ningning; Zheng, Zhongqing; Wang, Tao; Yang, Fang; Jiang, Xihui; Lin, Lin; Sun, Chao; Wang, Bangmao

    2017-05-01

    Peroral endoscopic myotomy (POEM) has emerged as an advanced technique for the treatment of achalasia, and defining the learning curve is mandatory. From August 2011 to June 2014, two operators in our institution (A&B) carried out POEM on 35 and 33 consecutive patients, respectively. Moving average and cumulative sum (CUSUM) methods were used to analyze the POEM learning curve for corrected operative time (cOT), referring to duration of per centimeter myotomy. Additionally, perioperative outcomes were compared among distinct learning curve phases. Using the moving average method, cOT reached a plateau at the 29th case and at the 24th case for operators A and B, respectively. CUSUM analysis identified three phases: initial learning period (Phase 1), efficiency period (Phase 2) and mastery period (Phase 3). The relatively smooth state in the CUSUM graph occurred at the 26th case and at the 24th case for operators A and B, respectively. Mean cOT of distinct phases for operator A were 8.32, 5.20 and 3.97 min, whereas they were 5.99, 3.06 and 3.75 min for operator B, respectively. Eckardt score and lower esophageal sphincter pressure significantly decreased during the 1-year follow-up period. Data were comparable regarding patient characteristics and perioperative outcomes. This single-center study demonstrated that expert endoscopists with experience in esophageal endoscopic submucosal dissection reached a plateau in learning of POEM after approximately 25 cases. © 2016 Japan Gastroenterological Endoscopy Society.

  7. Single versus bilateral lung transplantation for idiopathic pulmonary fibrosis: a ten-year institutional experience.

    PubMed

    Meyers, B F; Lynch, J P; Trulock, E P; Guthrie, T; Cooper, J D; Patterson, G A

    2000-07-01

    Between July 1988 and July 1998, we performed 433 lung transplants. Forty-five patients had idiopathic pulmonary fibrosis, and operations for these patients included 32 single lung transplants and 13 bilateral sequential lung transplants. This study reviews this experience and compares single lung transplantation and bilateral lung transplantation for pulmonary fibrosis. We performed a retrospective review, including inpatient hospital charts, outpatient clinic records, and telephone contact with patients to verify current health status. Perioperative mortality was 4 (8.9%) patients. One patient underwent redo bilateral lung transplantation for reperfusion injury and graft failure after single lung transplantation. The median hospitalization was 22 days. Actuarial survival at 1 and 5 years was 75.5% and 53.5%, respectively, which was not significantly different from our survival for all recipients (85.5% and 56.4%, respectively). Seventeen (41%) of 41 operative survivors have died. Late causes of death included obliterative bronchiolitis with respiratory failure (9), malignancy (3), and cytomegalovirus pneumonitis (2). Hospital mortality was 3 (9.4%) of 32 after single lung transplantation and 1 (7.7%) of 13 after bilateral lung transplantation. There was no difference between single and bilateral lung transplantation with regard to hospital stay. Four (12.5%) of the 32 patients undergoing single lung transplantation required tracheostomy, whereas 3 (23%) of 13 recipients undergoing bilateral lung transplantation required tracheostomy. Single or bilateral lung transplantations offer viable therapy for patients with pulmonary fibrosis. We demonstrate no benefit of bilateral over single lung transplantation for patients with this diagnosis. Survival after transplantation appears better than that of historic control subjects receiving standard medical care at other institutions.

  8. The learning curve of laparoendoscopic single-site (LESS) cholecystectomy: definable, short, and safe.

    PubMed

    Hernandez, Jonathan; Ross, Sharona; Morton, Connor; McFarlin, Kellie; Dahal, Sujat; Golkar, Farhaad; Albrink, Michael; Rosemurgy, Alexander

    2010-11-01

    The applications of laparoendoscopic single-site (LESS) surgery, including cholecystectomy, are occurring quickly, although little is generally known about issues associated with the learning curve of this new technique including operative time, conversion rates, and safety. We prospectively followed all patients undergoing LESS cholecystectomy, and compared operations undertaken at our institutions in cohorts of 25 patients with respect to operative times, conversion rates, and complications. One-hundred fifty patients of mean age 46 years underwent LESS cholecystectomy. No significant differences in operative times were demonstrable between any of the 25-patient cohorts operated on at our institution. A significant reduction in operative times (p < 0.001) after completion of 75 LESS procedures was, however, identified with the experience of a single surgeon. No significant reduction in the number of procedures requiring an additional trocar(s) or conversion to open operations was observed after completion of 25 LESS cholecystectomies. Complication rates were low, and not significantly different between any 25-patient cohorts. For surgeons proficient with multi-incision laparoscopic cholecystectomy, the learning curve for LESS cholecystectomy begins near proficiency. Operative complications and conversions were infrequent and unchanged across successive 25-patient cohorts, and were similar to those reported for multi-incision laparoscopic cholecystectomy after the learning curve. Copyright © 2010 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  9. Operation of Direct Drive Systems: Experiments in Peak Power Tracking and Multi-Thruster Control

    NASA Technical Reports Server (NTRS)

    Snyder, John Steven; Brophy, John R.

    2013-01-01

    Direct-drive power and propulsion systems have the potential to significantly reduce the mass of high-power solar electric propulsion spacecraft, among other advantages. Recent experimental direct-drive work has significantly mitigated or retired the technical risks associated with single-thruster operation, so attention is now moving toward systems-level areas of interest. One of those areas is the use of a Hall thruster system as a peak power tracker to fully use the available power from a solar array. A simple and elegant control based on the incremental conductance method, enhanced by combining it with the unique properties of Hall thruster systems, is derived here and it is shown to track peak solar array power very well. Another area of interest is multi-thruster operation and control. Dualthruster operation was investigated in a parallel electrical configuration, with both thrusters operating from discharge power provided by a single solar array. Startup and shutdown sequences are discussed, and it is shown that multi-thruster operation and control is as simple as for a single thruster. Some system architectures require operation of multiple cathodes while they are electrically connected together. Four different methods to control the discharge current emitted by individual cathodes in this configuration are investigated, with cathode flow rate control appearing to be advantageous. Dual-parallel thruster operation with equal cathode current sharing at total powers up to 10 kW is presented.

  10. Prediction of the effects of propeller operation on the static longitudinal stability of single-engine tractor monoplanes with flaps retracted

    NASA Technical Reports Server (NTRS)

    Weil, Joseph; Sleeman, William C , Jr

    1949-01-01

    The effects of propeller operation on the static longitudinal stability of single-engine tractor monoplanes are analyzed, and a simple method is presented for computing power-on pitching-moment curves for flap-retracted flight conditions. The methods evolved are based on the results of powered-model wind-tunnel investigations of 28 model configurations. Correlation curves are presented from which the effects of power on the downwash over the tail and the stabilizer effectiveness can be rapidly predicted. The procedures developed enable prediction of power-on longitudinal stability characteristics that are generally in very good agreement with experiment.

  11. Lessons Learned and Process Improvement for Payload Operations at the Launch Site

    NASA Technical Reports Server (NTRS)

    Catena, John; Gates, Donald, Jr.; Blaney, Kermit, Sr.; Obenschain, Arthur F. (Technical Monitor)

    2001-01-01

    For every space mission, there are challenges with the launch site/field operations process that are addressed too late in the development cycle. This potentially causes schedule delays, cost overruns, and adds risk to the mission success. This paper will discuss how a single interface, representing the payload at the launch site in all phases of development, will mitigate risk, and minimize or even alleviate potential problems later on. Experience has shown that a single interface between the project and the launch site allows for issues to be worked in a timely manner and bridges the gap between two diverse cultures.

  12. Approach to Spacelab Payload mission management

    NASA Technical Reports Server (NTRS)

    Craft, H. G.; Lester, R. C.

    1978-01-01

    The nucleus of the approach to Spacelab Payload mission management is the establishment of a single point of authority for the entire payload on a given mission. This single point mission manager will serve as a 'broker' between the individual experiments and the STS, negotiating agreements by two-part interaction. The payload mission manager, along with a small support team, will represent the users in negotiating use of STS accommodations. He will provide the support needed by each individual experimenter to meet the scientific, technological, and applications objectives of the mission with minimum cost and maximum efficiency. The investigator will assume complete responsibility for his experiment hardware definition and development and will take an active role in the integration and operation of his experiment.

  13. Optimization of identity operation in NMR spectroscopy via genetic algorithm: Application to the TEDOR experiment

    NASA Astrophysics Data System (ADS)

    Manu, V. S.; Veglia, Gianluigi

    2016-12-01

    Identity operation in the form of π pulses is widely used in NMR spectroscopy. For an isolated single spin system, a sequence of even number of π pulses performs an identity operation, leaving the spin state essentially unaltered. For multi-spin systems, trains of π pulses with appropriate phases and time delays modulate the spin Hamiltonian to perform operations such as decoupling and recoupling. However, experimental imperfections often jeopardize the outcome, leading to severe losses in sensitivity. Here, we demonstrate that a newly designed Genetic Algorithm (GA) is able to optimize a train of π pulses, resulting in a robust identity operation. As proof-of-concept, we optimized the recoupling sequence in the transferred-echo double-resonance (TEDOR) pulse sequence, a key experiment in biological magic angle spinning (MAS) solid-state NMR for measuring multiple carbon-nitrogen distances. The GA modified TEDOR (GMO-TEDOR) experiment with improved recoupling efficiency results in a net gain of sensitivity up to 28% as tested on a uniformly 13C, 15N labeled microcrystalline ubiquitin sample. The robust identity operation achieved via GA paves the way for the optimization of several other pulse sequences used for both solid- and liquid-state NMR used for decoupling, recoupling, and relaxation experiments.

  14. Is retrograde intrarenal surgery the game changer in the management of upper tract calculi? A single-center single-surgeon experience of 131 cases.

    PubMed

    Parikh, Kandarp Priyakant; Jain, Ravi Jineshkumar; Kandarp, Aditya Parikh

    2018-01-01

    Success of any modality for stone disease needs to be evaluated in terms of Stone Free Rates (SFR), auxiliary procedures needed; complications and follow up. SFR in RIRS is subject to parameters like stone burden, location, number, hardness, composition; calyceal and ureter anatomy; use of ureteric access sheath (UAS); surgeon experience etc. The aim of this study is to evaluate the efficacy and safety of RIRS for managing upper tract stones. The objectives include evaluating SFR in RIRS in relation to stone burden, location and number. Other objectives include evaluating SFR after re RIRS in relation to stone burden, necessity of pre DJ stenting, use of UAS and post operative complication rate. 131 patients operated by single surgeon for single/multiple renal and/or upper ureteric stones were evaluated. Stone size > 3 mm on follow up CT KUB was considered as residual. Re RIRS was required for residual stones. The overall SFR was 76%. SFR were statistically lower with stone burden > 1.5 cm, lower calyceal stones and single stones with stone burden > 1.5 cm. SFR was 90% after 2 nd RIRS and 98.5% after 3 rd RIRS procedure. No significant difference in SFR was noted between single v/s multiple stones, single calyx v/s multiple calyx stones and renal v/s upper ureteric stones. No major complication was noted. Larger stone burden and lower calyceal location are important factors deciding SFR in RIRS. With auxiliary procedure, RIRS is safe and effective compared to PCNL.

  15. Preparing the MAX IV storage rings for timing-based experiments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stråhlman, C., E-mail: Christian.Strahlman@maxlab.lu.se; Olsson, T., E-mail: Teresia.Olsson@maxlab.lu.se; Leemann, S. C.

    2016-07-27

    Time-resolved experimental techniques are increasingly abundant at storage ring facilities. Recent developments in accelerator technology and beamline instrumentation allow for simultaneous operation of high-intensity and timing-based experiments. The MAX IV facility is a state-of-the-art synchrotron light source in Lund, Sweden, that will come into operation in 2016. As many storage ring facilities are pursuing upgrade programs employing strong-focusing multibend achromats and passive harmonic cavities (HCs) in high-current operation, it is of broad interest to study the accelerator and instrumentation developments required to enable timing-based experiments at such machines. In particular, the use of hybrid filling modes combined with pulse pickingmore » by resonant excitation or pseudo single bunch has shown promising results. These methods can be combined with novel beamline instrumentation, such as choppers and instrument gating. In this paper we discuss how these techniques can be implemented and employed at MAX IV.« less

  16. Family stressors and postdeployment mental health in single versus partnered parents deployed in support of the wars in Afghanistan and Iraq.

    PubMed

    Vaughn-Coaxum, Rachel; Smith, Brian N; Iverson, Katherine M; Vogt, Dawne

    2015-08-01

    Little is known about the family-related stress and postdeployment adjustment of single versus partnered parents deployed in support of the wars in Iraq and Afghanistan. This study examined exposure to family-related stressors during and after deployment, as well as postdeployment psychological symptoms in a national sample of 318 single (n = 74) and partnered (n = 244) parent veterans of Operation Enduring Freedom and Operation Iraqi Freedom. Results demonstrated that single parents experienced higher levels of concern about life and family disruptions during deployment, lower levels of social support during and after deployment, and poorer postdeployment family functioning than partnered parents. Single parents also reported higher posttraumatic stress symptom severity, but not depression or anxiety symptom severity, compared with partnered parents. Family-related stressors demonstrated different associations with mental health for single and partnered parents, suggesting that some stressor-symptom relations may be more salient for single parents, and others may be more salient for partnered parents. Findings suggest that the deployment and postdeployment experiences of parents differ based on their partnered status, which has implications for the design and provision of services to single and partnered parents. (c) 2015 APA, all rights reserved).

  17. Single Incision Laparoscopic Assisted Appendectomy: Experience of 82 Cases

    PubMed Central

    Sinha, Anant Narayan; Deepak, Desh; Pandey, NK; Nandani

    2016-01-01

    Introduction Single Incision Laparoscopic Surgery (SILS) is one of the most recent developments which have been made in the field of minimal assesses surgery. It has potential advantages of less postoperative pain and better cosmesis, but at the same time, this procedure is time consuming and it increases the cost of surgery. Aim In this study, we evaluated the feasibility, safety and potential advantages of single incision laparoscopic assisted appendectomy. Materials and Methods Single incision laparoscopic assisted appendectomy was done in 82 patients who were diagnosed with acute or chronic appendicitis. A single 10mm incision made over right lower quadrant was used for placing two 5mm trocars and appendisectomy was done as in open surgery, after delivering out the appendix from the incision. Results Mean operative time was 32.56 ± 15.5 minutes. Mean post-operative pain scores as per visual analogue scalewere 6.5, 4.2 and 1.2 on 12 hours day 1 and day 2 after surgery respectively. Mean length of hospital stay was 1.4 ± 1.2 days. Conclusion Single incision laparoscopic appendectomy is safe and feasible. PMID:27437295

  18. Short-term ensemble streamflow forecasting using operationally-produced single-valued streamflow forecasts - A Hydrologic Model Output Statistics (HMOS) approach

    NASA Astrophysics Data System (ADS)

    Regonda, Satish Kumar; Seo, Dong-Jun; Lawrence, Bill; Brown, James D.; Demargne, Julie

    2013-08-01

    We present a statistical procedure for generating short-term ensemble streamflow forecasts from single-valued, or deterministic, streamflow forecasts produced operationally by the U.S. National Weather Service (NWS) River Forecast Centers (RFCs). The resulting ensemble streamflow forecast provides an estimate of the predictive uncertainty associated with the single-valued forecast to support risk-based decision making by the forecasters and by the users of the forecast products, such as emergency managers. Forced by single-valued quantitative precipitation and temperature forecasts (QPF, QTF), the single-valued streamflow forecasts are produced at a 6-h time step nominally out to 5 days into the future. The single-valued streamflow forecasts reflect various run-time modifications, or "manual data assimilation", applied by the human forecasters in an attempt to reduce error from various sources in the end-to-end forecast process. The proposed procedure generates ensemble traces of streamflow from a parsimonious approximation of the conditional multivariate probability distribution of future streamflow given the single-valued streamflow forecast, QPF, and the most recent streamflow observation. For parameter estimation and evaluation, we used a multiyear archive of the single-valued river stage forecast produced operationally by the NWS Arkansas-Red River Basin River Forecast Center (ABRFC) in Tulsa, Oklahoma. As a by-product of parameter estimation, the procedure provides a categorical assessment of the effective lead time of the operational hydrologic forecasts for different QPF and forecast flow conditions. To evaluate the procedure, we carried out hindcasting experiments in dependent and cross-validation modes. The results indicate that the short-term streamflow ensemble hindcasts generated from the procedure are generally reliable within the effective lead time of the single-valued forecasts and well capture the skill of the single-valued forecasts. For smaller basins, however, the effective lead time is significantly reduced by short basin memory and reduced skill in the single-valued QPF.

  19. A single cell penetration system by ultrasonic driving

    NASA Astrophysics Data System (ADS)

    Zhou, Zhaoying; Xiao, Mingfei; Yang, Xing; Wu, Ting

    2008-12-01

    The researches of single cell's control and operation are the hotspots in whole world. Among the various technologies, the transmission of ectogenic genetic materials between cell membrane is very significant. Imitating the Chinese traditional acupuncture therapy, a new ultrasonic resonance driving method, is imported to drive a cell's penetration probe. A set of the single cell penetration system was established to perform this function. This system includes four subsystems: driving part, micromanipulation part, observation and measurement part, and actuation part. Some fish egg experiments indicate that this system is workable and effective.

  20. Development of Low $$\\beta $$ Single-Spoke Resonators for the Front End of the Proton Improvement Plan-II at Fermilab

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Awida, Mohamed H.; Passarelli, Donato; Berrutti, Paolo

    A total of ten jacketed single-spoke resonators type 1 (SSR1) have been fabricated for Fermilab' injection experiment (PIP2IT). PIP2IT is a test bed for Fermilab's future accelerator named proton improvement plan II that is currently under development. SSR1 cavities operate at 325 MHz to accelerate a proton beam at a relative (to speed of light) velocity (β = 0.22). In this study, we present Fermilab's experience in developing those spoke resonators starting from the design and analysis phase, to fabrication and extensive testing to qualify cavities for cryomodule assembly.

  1. Development of Low $$\\beta $$ Single-Spoke Resonators for the Front End of the Proton Improvement Plan-II at Fermilab

    DOE PAGES

    Awida, Mohamed H.; Passarelli, Donato; Berrutti, Paolo; ...

    2017-08-18

    A total of ten jacketed single-spoke resonators type 1 (SSR1) have been fabricated for Fermilab' injection experiment (PIP2IT). PIP2IT is a test bed for Fermilab's future accelerator named proton improvement plan II that is currently under development. SSR1 cavities operate at 325 MHz to accelerate a proton beam at a relative (to speed of light) velocity (β = 0.22). In this study, we present Fermilab's experience in developing those spoke resonators starting from the design and analysis phase, to fabrication and extensive testing to qualify cavities for cryomodule assembly.

  2. Robot-assisted vasovasostomy using a single layer anastomosis.

    PubMed

    Marshall, Michael T; Doudt, Alexander D; Berger, Jonathan H; Auge, Brian K; Christman, Matthew S; Choe, Chong H

    2017-09-01

    Of all patients who have vasectomies performed in the United States, upwards of 6% will pursue a vasectomy reversal. Currently, the gold-standard reversal procedure is a microscopic vasovasostomy utilizing either a one or two-layer vasal anastomosis. Unfortunately, most urologists do not perform these procedures as they require extensive training and experience in microsurgery. The objective of our study was to evaluate the feasibility and success rate of robot-assisted vasovasostomy performed at our institution. We completed a retrospective review of our experience with vasectomy reversal utilizing the da Vinci ® Surgical System and a single layer vasal anastomosis. A successful reversal was defined as a return of sperm on semen analysis or light microscopy. Since 2009 we have completed 79 robotic vasectomy reversals, 60 of which utilized a single-layer vasal anastomosis. The average obstructive interval was 5.7 ± 2.2 years. Average operative time was 192 min. 42 patients returned for a post-operative semen evaluation at an average time of 4.3 months post-procedure revealing a success rate of 88% (37 out of 42). Post-operative semen parameters were significant for an average sperm density of 31.0 million/mL with an average motility of 29.1%. Robot-assisted vasovasostomy with a single layer anastomosis has overall success rates that are similar to that of reported microscopic vasovasostomy rates. Although more study is warranted with regard to cost, we feel as though our study demonstrates an alternative approach to vasectomy reversal that can be performed successfully by urologists trained in robotic surgery.

  3. Pure state consciousness and its local reduction to neuronal space

    NASA Astrophysics Data System (ADS)

    Duggins, A. J.

    2013-01-01

    The single neuronal state can be represented as a vector in a complex space, spanned by an orthonormal basis of integer spike counts. In this model a scalar element of experience is associated with the instantaneous firing rate of a single sensory neuron over repeated stimulus presentations. Here the model is extended to composite neural systems that are tensor products of single neuronal vector spaces. Depiction of the mental state as a vector on this tensor product space is intended to capture the unity of consciousness. The density operator is introduced as its local reduction to the single neuron level, from which the firing rate can again be derived as the objective correlate of a subjective element. However, the relational structure of perceptual experience only emerges when the non-local mental state is considered. A metric of phenomenal proximity between neuronal elements of experience is proposed, based on the cross-correlation function of neurophysiology, but constrained by the association of theoretical extremes of correlation/anticorrelation in inseparable 2-neuron states with identical and opponent elements respectively.

  4. High speed systems for time-resolved experiments with synchrotron radiation

    NASA Astrophysics Data System (ADS)

    Koziol, Anna; Maj, Piotr

    2018-02-01

    The UFXC32k is a single photon counting hybrid pixel detector with 75 μm pixel pitch. It was designed to cope with high X-ray intensities and therefore it is a very good candiate for synchrotron applications. In order to use this detector in an application, a dedicated setup must be designed and built allowing proper operation of the detector within the experiment. The paper presents two setups built for the purpose of Pump-Probe-Probe experiments at the Synchrotron SOLEIL and XPCS experiments at the APS.

  5. Diode-side-pumped 131 W, 1319 nm single-wavelength cw Nd:YAG laser.

    PubMed

    Haiyong, Zhu; Ge, Zhang; Chenghui, Huang; Yong, Wei; Lingxiong, Huang; Jing, Chen; Weidong, Chen; Zhenqiang, Chen

    2007-01-20

    A diode-side-pumped high-power 1319 nm single-wavelength Nd:YAG continuous wave (cw) laser is described. Through reasonable coating design of the cavity mirrors, the 1064 nm strongest line as well as the 1338 nm one have been successfully suppressed. The laser output powers corresponding to four groups of different output couplers operating at 1319 nm single wavelength have been compared. The output coupler with the transmission T=5.3% has the highest output power, and a 131 W cw output power was achieved at the pumping power of 555 W. The optical-optical conversion efficiency is 23.6%, and the slope efficiency is 46%. The output power is higher than the total output power of the dual-wavelength laser operating at 1319 nm and 1338 nm in the experiment.

  6. Intelligent transportation systems field operational test cross-cutting study : commercial vehicle administrative processes

    DOT National Transportation Integrated Search

    1999-10-01

    This analysis brief explores differences and similarities among the national crash experience of combination-unit trucks (CUTs), single-unit trucks (SUTs), and "all vehicles" (principally cars and light truck/vans). These CUT vs. SUT vs. all vehicle ...

  7. Analysis of dewar and transfer line cooldown in Superfluid Helium On-Orbit Transfer Flight Experiment (SHOOT)

    NASA Technical Reports Server (NTRS)

    Ng, Y. S.; Lee, J. H.

    1989-01-01

    The Superfluid Helium On-Orbit Transfer Flight Experiment (SHOOT) is designed to demonstrate the techniques and components required for orbital superfluid (He II) replenishment of observatories and satellites. One of the tasks planned in the experiment is to cool a warm cryogen tank and a warm transfer line to liquid helium temperature. A math model, based on single-phase vapor flow heat transfer, has been developed to predict the cooldown time, component temperature histories, and helium consumption rate, for various initial conditions of the components and for the thermomechanical pump heater powers of 2 W and 0.5 W. This paper discusses the model and the analytical results, which can be used for planning the experiment operations and determining the pump heater power required for the cooldown operation.

  8. Space Processing Applications Rocket project SPAR III

    NASA Technical Reports Server (NTRS)

    Reeves, F.

    1978-01-01

    This document presented the engineering report and science payload III test report and summarized the experiment objectives, design/operational concepts, and final results of each of five scientific experiments conducted during the third Space Processing Applications Rocket (SPAR) flight flown by NASA in December 1976. The five individual SPAR experiments, covering a wide and varied range of scientific materials processing objectives, were entitled: Liquid Mixing, Interaction of Bubbles with Solidification Interfaces, Epitaxial Growth of Single Crystal Film, Containerless Processing of Beryllium, and Contact and Coalescence of Viscous Bodies.

  9. Quasi-Solid-State Single-Atom Transistors.

    PubMed

    Xie, Fangqing; Peukert, Andreas; Bender, Thorsten; Obermair, Christian; Wertz, Florian; Schmieder, Philipp; Schimmel, Thomas

    2018-06-21

    The single-atom transistor represents a quantum electronic device at room temperature, allowing the switching of an electric current by the controlled and reversible relocation of one single atom within a metallic quantum point contact. So far, the device operates by applying a small voltage to a control electrode or "gate" within the aqueous electrolyte. Here, the operation of the atomic device in the quasi-solid state is demonstrated. Gelation of pyrogenic silica transforms the electrolyte into the quasi-solid state, exhibiting the cohesive properties of a solid and the diffusive properties of a liquid, preventing the leakage problem and avoiding the handling of a liquid system. The electrolyte is characterized by cyclic voltammetry, conductivity measurements, and rotation viscometry. Thus, a first demonstration of the single-atom transistor operating in the quasi-solid-state is given. The silver single-atom and atomic-scale transistors in the quasi-solid-state allow bistable switching between zero and quantized conductance levels, which are integer multiples of the conductance quantum G 0  = 2e 2 /h. Source-drain currents ranging from 1 to 8 µA are applied in these experiments. Any obvious influence of the gelation of the aqueous electrolyte on the electron transport within the quantum point contact is not observed. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. SPIDER ® sleeve gastrectomy--a new concept in single-trocar bariatric surgery: initial experience and technical details.

    PubMed

    Noel, P; Nedelcu, M; Gagner, M

    2014-04-01

    Single port instrument delivery extended reach (SPIDER(®)) surgical system is a revolutionary surgical platform that allows triangulation of the surgical instruments while eliminating the crossing of instruments, the problematic characteristic of single access laparoscopic surgery. The purpose of this study was to analyze our initial experience with SPIDER(®) sleeve gastrectomy and to present the technical details of this new minimally invasive approach, performed in ten patients at the La Casamance Private Hospital between November 2012 and April 2013. All patients were reviewed at scheduled post-operative consultations at 1, 3 and 6 months. In addition to clinical examination, the post-operative consultation at one month also included a satisfaction survey using the Moorehead-Ardelt questionnaire. An initial series of ten sleeve gastrectomies were performed in female patients with a mean age of 41.5 years (range: 2-52). The mean BMI was 40.11 (range: 37.25-44.3). The intervention was performed through a single trocar in all patients with no "conversion" to classic laparoscopy or open surgery. The mean operative time was 61 ± 15.22 minutes (SD=standard deviation) (range: 43-96 min). The mean BMI at one month was 35.5 (SD:± 3.58, SEM: ± 1.13) (SEM=standard error of mean) with an average percentage of excess weight loss (%EWL) of 32.9% (SD:± 8.56%, SEM:± 2.71%). The mean BMI at three months was 32.4 (SD: ± 2.78, SEM: ± 0.88) with an average %EWL of 52.7% (SD: ± 8.64%, SEM: ± 2.73%). The mean BMI at six months was 29.9 (SD:± 2.60, SEM: ± 0.98) with a mean %EWL of 68.8% (SD: ± 8.38%, SEM:± 3.17%). Complete remission of co-morbid conditions was observed in four patients, improvement in three others, and no change in a single patient. The mean duration of hospitalization was 3.1 days. The mean follow-up period was 161 days (SD:± 57.4 days, range: 90-243 days). There was no mortality and no intra-operative and post-operative complications were noted. The SPIDER(®) surgical platform seems to be a usable and effective method for performance of minimally invasive single-access sleeve gastrectomy, offering an easy and efficient operative procedure compared to other single-port systems. Prospective long-term studies are recommended before this approach can be validated to be of comparable efficiency to conventional multi-port laparoscopic surgery. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  11. Improved long-term survival after intra-operative single high-dose ATG-Fresenius induction in renal transplantation: a single centre experience.

    PubMed

    Kaden, Jürgen; May, Gottfried; Völp, Andreas; Wesslau, Claus

    2009-01-01

    In organ grafts donor-specific sensitization is initiated immediately after revascularization. Therefore, in 1990 we introduced the intra-operative single high-dose ATG-Fresenius (ATG-F) induction in addition to standard triple drug therapy (TDT) consisting of steroids, azathioprine and cyclosporin. A total of 778 first renal transplantations from deceased donors, performed between 1987 and 1998, were included in this evaluation. This retrospective analysis of clinic records and electronic databases presents data of all recipients of first kidney grafts who received two different ATG-F inductions (1(st) group: 9 mg/kg body weight as single high-dose intra-operatively, n=484; 2(nd) group: 3 mg/kg body weight on 7 or 8 consecutive days as multiple-dose starting also intra-operatively, n=78) and standard TDT alone (3(rd) group: TDT alone, n=216). The 10-year patient survival rates were 72.6+/-2.6% (TDT + ATG-F single high-dose), 79.5+/-5.1% (TDT + ATG-F multiple-dose) and 67.2+/-3.7%% (TDT alone; Kaplan-Meier estimates with standard errors; ATG-F vs TDT alone, p=0.001). The 10-year graft survival rates with censoring of patients that died with a functioning graft were 73.8+/-2.4%, 57.7+/-5.8% and 58.4+/-3.6% (Kaplan-Meier estimates with standard errors; 1(st) vs 2(nd )and 3(rd) group, respectively, p<0.001) and the 10-year graft survival rates with patient death counted as graft failure were 58.3+/-2.7%, 55.7+/-5.8% and 48.2+/-3.5% (Kaplan-Meier estimates with standard errors; ATG-F single high-dose vs TDT, p=0.023). In pre-sensitized recipients there were also significant differences in favour of ATG-F, more notably in the single high-dose ATG-F induction. A total of 69% of the patients in the two cohorts receiving ATG-F did not experience any transplant rejections compared to 56% in patients undergoing TDT alone (p=0.018). The incidence of infectious complications was comparable across all groups. According to evidence obtained from the routine documentation of 778 renal transplantations, ATG-F induction therapy administered as a part of immunosuppressive therapy significantly improves patient survival and reduces the risk of graft failure and transplant rejections.

  12. Measuring Incompatible Observables by Exploiting Sequential Weak Values.

    PubMed

    Piacentini, F; Avella, A; Levi, M P; Gramegna, M; Brida, G; Degiovanni, I P; Cohen, E; Lussana, R; Villa, F; Tosi, A; Zappa, F; Genovese, M

    2016-10-21

    One of the most intriguing aspects of quantum mechanics is the impossibility of measuring at the same time observables corresponding to noncommuting operators, because of quantum uncertainty. This impossibility can be partially relaxed when considering joint or sequential weak value evaluation. Indeed, weak value measurements have been a real breakthrough in the quantum measurement framework that is of the utmost interest from both a fundamental and an applicative point of view. In this Letter, we show how we realized for the first time a sequential weak value evaluation of two incompatible observables using a genuine single-photon experiment. These (sometimes anomalous) sequential weak values revealed the single-operator weak values, as well as the local correlation between them.

  13. Measuring Incompatible Observables by Exploiting Sequential Weak Values

    NASA Astrophysics Data System (ADS)

    Piacentini, F.; Avella, A.; Levi, M. P.; Gramegna, M.; Brida, G.; Degiovanni, I. P.; Cohen, E.; Lussana, R.; Villa, F.; Tosi, A.; Zappa, F.; Genovese, M.

    2016-10-01

    One of the most intriguing aspects of quantum mechanics is the impossibility of measuring at the same time observables corresponding to noncommuting operators, because of quantum uncertainty. This impossibility can be partially relaxed when considering joint or sequential weak value evaluation. Indeed, weak value measurements have been a real breakthrough in the quantum measurement framework that is of the utmost interest from both a fundamental and an applicative point of view. In this Letter, we show how we realized for the first time a sequential weak value evaluation of two incompatible observables using a genuine single-photon experiment. These (sometimes anomalous) sequential weak values revealed the single-operator weak values, as well as the local correlation between them.

  14. Operation condition for continuous anti-solvent crystallization of CBZ-SAC cocrystal considering deposition risk of undesired crystals

    NASA Astrophysics Data System (ADS)

    Nishimaru, Momoko; Nakasa, Miku; Kudo, Shoji; Takiyama, Hiroshi

    2017-07-01

    Crystallization operation of cocrystal production has deposition risk of undesired crystals. Simultaneously, continuous manufacturing processes are focused on. In this study, conditions for continuous cocrystallization considering risk reduction of undesired crystals deposition were investigated on the view point of thermodynamics and kinetics. The anti-solvent cocrystallization was carried out in four-component system of carbamazepine, saccharin, methanol and water. From the preliminary batch experiment, the relationships among undesired crystal deposition, solution composition decided by mixing ratio of solutions, and residence time for the crystals were considered, and then the conditions of continuous experiment were decided. Under these conditions, the continuous experiment was carried out. The XRD patterns of obtained crystals in the continuous experiment showed that desired cocrystals were obtained without undesired crystals. This experimental result was evaluated by using multi-component phase diagrams from the view point of the operation point's movement. From the evaluation, it was found that there is a certain operation condition which the operation point is fixed with time in the specific domain without the deposition risk of undesired single component crystals. It means the possibility of continuous production of cocrystals without deposition risk of undesired crystals was confirmed by using multi-component phase diagrams.

  15. Radioactive Seed Localization Versus Wire Localization for Nonpalpable Breast Lesions: A Two-Year Initial Experience at a Large Community Hospital.

    PubMed

    Stelle, Lacey; Schoenheit, Taylor; Brubaker, Allison; Tang, Xiwei; Qu, Peiyong; Cradock, Kimberly; Higham, Anna

    2018-01-01

    Radioactive seed localization (RSL) is a safe and effective alternative to wire localization (WL) for nonpalpable breast lesions. While several large academic institutions currently utilize RSL, few community hospitals have adopted this technique. The aim of this study was to examine the experience of RSL versus WL at a large community hospital. A retrospective chart review of patients who underwent RSL or WL for breast-conserving surgery from 1 November 2013 to 31 November 2015. The total number of lesions examined was 382. RSL was utilized in 205 (54%) lesions, with 187 undergoing single RSL, while WL was used in 155 (40%) lesions, with 109 undergoing single WL; both techniques were used in 22 (6%) lesions. Pathology was benign in 142 (48%) lesions, with 93 RSLs and 49 WLs. For malignant lesions, mean specimen size was 36.3 g for single RSL and 35.9 g for single WL (p = 0.904). Re-excision for margin clearance was required for 16 (17%) malignant lesions in the RSL group and 10 (17%) in the WL group (p = 0.954). For malignant lesions, mean operating room time was 86 min for single RSL versus 70 min for single WL (p = 0.014). The use of RSL is a viable option in the community setting, with several benefits over WL. While operative times were slightly longer with RSL, there was no difference in specimen size or re-excision rate for malignant lesions.

  16. Competition between multiple words for a referent in cross-situational word learning

    PubMed Central

    Benitez, Viridiana L.; Yurovsky, Daniel; Smith, Linda B.

    2016-01-01

    Three experiments investigated competition between word-object pairings in a cross-situational word-learning paradigm. Adults were presented with One-Word pairings, where a single word labeled a single object, and Two-Word pairings, where two words labeled a single object. In addition to measuring learning of these two pairing types, we measured competition between words that refer to the same object. When the word-object co-occurrences were presented intermixed in training (Experiment 1), we found evidence for direct competition between words that label the same referent. Separating the two words for an object in time eliminated any evidence for this competition (Experiment 2). Experiment 3 demonstrated that adding a linguistic cue to the second label for a referent led to different competition effects between adults who self-reported different language learning histories, suggesting both distinctiveness and language learning history affect competition. Finally, in all experiments, competition effects were unrelated to participants’ explicit judgments of learning, suggesting that competition reflects the operating characteristics of implicit learning processes. Together, these results demonstrate that the role of competition between overlapping associations in statistical word-referent learning depends on time, the distinctiveness of word-object pairings, and language learning history. PMID:27087742

  17. A platform for exploding wires in different media

    NASA Astrophysics Data System (ADS)

    Han, Ruoyu; Wu, Jiawei; Qiu, Aici; Zhou, Haibin; Wang, Yanan; Yan, Jiaqi; Ding, Weidong

    2017-10-01

    A platform SWE-2 used for single wire explosion experiments has been designed, established, and commissioned. This paper describes the design and initial experiments of SWE-2. In summary, two pulsed current sources based on pulse capacitors and spark gaps are adopted to drive sub-microsecond and microsecond time scale wire explosions in a gaseous/liquid medium, respectively. In the initial experiments, a single copper wire was exploded in air, helium, and argon with a 0.1-0.3 MPa ambient pressure as well as tap water with a 283-323 K temperature, 184-11 000 μ S/cm conductivity, or 0.1-0.9 MPa hydrostatic pressure. In addition, the diagnostic system is introduced in detail. Energy deposition, optical emission, and shock wave characteristics are briefly discussed based on experimental results. The platform was demonstrated to operate successfully with a single wire load. These results provide the potential for further applications of this platform, such as plasma-matter interactions, shock wave effects, and reservoir simulations.

  18. Plug into a Network.

    ERIC Educational Resources Information Center

    Vander Linden, Doug; Clark, Larry

    1994-01-01

    Stand-alone, single-user software programs for classroom use can be prohibitively expensive, compared to information-sharing network systems. Based on a Kansas district's experience, this article explains three types of networks (device-sharing, operating-system-based, and client-server-based) and discusses network protocols, software choices,…

  19. Superconducting Switch for Fast On-Chip Routing of Quantum Microwave Fields

    NASA Astrophysics Data System (ADS)

    Pechal, M.; Besse, J.-C.; Mondal, M.; Oppliger, M.; Gasparinetti, S.; Wallraff, A.

    2016-08-01

    A switch capable of routing microwave signals at cryogenic temperatures is a desirable component for state-of-the-art experiments in many fields of applied physics, including but not limited to quantum-information processing, communication, and basic research in engineered quantum systems. Conventional mechanical switches provide low insertion loss but disturb operation of dilution cryostats and the associated experiments by heat dissipation. Switches based on semiconductors or microelectromechanical systems have a lower thermal budget but are not readily integrated with current superconducting circuits. Here we design and test an on-chip switch built by combining tunable transmission-line resonators with microwave beam splitters. The device is superconducting and as such dissipates a negligible amount of heat. It is compatible with current superconducting circuit fabrication techniques, operates with a bandwidth exceeding 100 MHz, is capable of handling photon fluxes on the order of 1 05 μ s-1 , equivalent to powers exceeding -90 dBm , and can be switched within approximately 6-8 ns. We successfully demonstrate operation of the device in the quantum regime by integrating it on a chip with a single-photon source and using it to route nonclassical itinerant microwave fields at the single-photon level.

  20. Description of Simulated Small Satellite Operation Data Sets

    NASA Technical Reports Server (NTRS)

    Kulkarni, Chetan S.; Guarneros Luna, Ali

    2018-01-01

    A set of two BP930 batteries (Identified as PK31 and PK35) were operated continuously for a simulated satellite operation profile completion for single cycle. The battery packs were charged to an initial voltage of around 8.35 V for 100% SOC before the experiment was started. This document explains the structure of the battery data sets. Please cite this paper when using this dataset: Z. Cameron, C. Kulkarni, A. Guarneros, K. Goebel, S. Poll, "A Battery Certification Testbed for Small Satellite Missions", IEEE AUTOTESTCON 2015, Nov 2-5, 2015, National Harbor, MA

  1. Startup and mode competition in a 420 GHz gyrotron

    NASA Astrophysics Data System (ADS)

    Qixiang Zhao, A.; Sheng Yu, B.; Tianzhong Zhang, C.

    2017-09-01

    In the experiments of a 420 GHz second-harmonic gyrotron, it is found that the electron beam voltage and current ranges for single mode operation of TE17.4 are slightly narrower than those in the simulation. To explain this phenomenon, the startup scenario has been investigated with special emphasis on mode competition. The calculations indicate that the decreases of the operating ranges are caused by the voltage overshoot in the startup scenario.

  2. Combined robotic transanal total mesorectal excision (R-taTME) and single-site plus one-port (R-SSPO) technique for ultra-low rectal surgery-initial experience with a new operation approach.

    PubMed

    Kuo, Li-Jen; Ngu, James Chi-Yong; Tong, Yiu-Shun; Chen, Chia-Che

    2017-02-01

    Robot-assisted rectal surgery is gaining popularity, and robotic single-site surgery is also being explored clinically. We report our initial experience with robotic transanal total mesorectal excision (R-taTME) and radical proctectomy using the robotic single-site plus one-port (R-SSPO) technique for low rectal surgery. Between July 2015 and March 2016, 15 consecutive patients with ultra-low rectal lesions underwent R-taTME followed by radical proctectomy using the R-SSPO technique by a single surgeon. The clinical and pathological results were retrospectively analyzed. The median operative time was 473 (range, 335-569) min, and the estimated blood loss was 33 (range, 30-50) mL. The median number of lymph nodes harvested was 12 (range, 8-18). The median distal resection margin was 1.4 (range, 0.4-3.5) cm, and all patients had clear circumferential resection margins. We encountered a left ureteric transection intraoperatively in one patient, and another patient required reoperation for postoperative adhesive intestinal obstruction. There was no 30-day mortality. R-taTME followed by radical proctectomy using the R-SSPO technique for patients with low rectal lesions is technically feasible and safe without compromising oncologic outcomes. However, there were considerable limitations and a steep learning curve using current robotic technology.

  3. Single payers, multiple systems: the scope and limits of subnational variation under a Federal health policy framework.

    PubMed

    Tuohy, Carolyn Hughes

    2009-08-01

    In political discourse, the term "single-payer system" originated in an attempt to stake out a middle ground between the public and private sectors in providing universal access to health care. In this view, a single-payer system is one in which health care is financed by government and delivered by privately owned and operated health care providers. The term appears to have been coined in U.S. policy debates to provide a rhetorical reference point for universal health insurance other than the "socialized medicine" of state-owned and -operated health care providers. This article, like others in this special issue, is meant to provide a more nuanced view of single-payer systems. In particular, it reviews experience in the prototypical single-payer system for physician and hospital services: the Canadian case. Given Canada's federal governance structure, this example also aptly illuminates the scope and limits of subnational variation within this single model of health care finance. And what it demonstrates in essence is that the very feature that defines the single-payer prototype -- the maintenance of independent providers remunerated by a single public payer in each province -- also leads to a set of profession-state bargains that define the limits of variation.

  4. Experimental quantum information processing with the Talbot effect

    NASA Astrophysics Data System (ADS)

    Sawada, K.; Walborn, S. P.

    2018-07-01

    We report a proof of concept experiment illustrating the implementation of several simple quantum logic gates on D-level quantum systems (quDits) using the Talbot effect. A number of QuDit states are encoded into the transverse profile of a paraxial laser beam using a spatial light modulator. These states are transformed through a diagonal phase element and then free-propagation via the fractional Talbot effect, demonstrating the realization of some well-known single quDit gates in quantum computation. Our classical optics experiment allows us to identify several important technical details, and serves as a first experimental step in performing D-dimensional quantum operations with single photons or other quantum systems using this scheme.

  5. Housing and testing in mixed-sex rooms increases motivation and accuracy during operant testing in both male and female mice.

    PubMed

    Lloyd, Kelsey R; Yaghoubi, Sarah K; Makinson, Ryan A; McKee, Sarah E; Reyes, Teresa M

    2018-04-01

    Operant behavior tasks are widely used in neuroscience research, but little is known about how variables such as housing and testing conditions affect rodent operant performance. We have previously observed differences in operant performance in male and female mice depending on whether mice were housed and tested in rooms containing only one sex versus rooms containing both sexes. Here, male and female mice in either single-sex or mixed sex housing rooms were trained on fixed ratio 1 (FR1) and progressive ratio (PR) tasks. For both sexes, animals in the mixed sex room had more accurate performance in FR1 and were more motivated in the PR task. We then moved the single sex housed animals to the mixed sex room and vice versa. Animals that started in mixed sex housing had no change to PR, but both sexes who started in single sex housing were more motivated after the switch. Additionally, the females that moved into single-sex housing performed less accurately in FR1. We conclude that housing and testing conditions can affect performance on FR1 and PR tasks. As these tasks are commonly used as training steps to more complex tasks, housing and testing conditions should be carefully considered during experiment design and reported in publications. Copyright © 2018 Elsevier Inc. All rights reserved.

  6. The Single-Phase ProtoDUNE Technical Design Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abi, B.

    2017-06-21

    ProtoDUNE-SP is the single-phase DUNE Far Detector prototype that is under construction and will be operated at the CERN Neutrino Platform (NP) starting in 2018. ProtoDUNE-SP, a crucial part of the DUNE effort towards the construction of the first DUNE 10-kt fiducial mass far detector module (17 kt total LAr mass), is a significant experiment in its own right. With a total liquid argon (LAr) mass of 0.77 kt, it represents the largest monolithic single-phase LArTPC detector to be built to date. It's technical design is given in this report.

  7. New Developments in Robotics and Single-site Gynecologic Surgery.

    PubMed

    Matthews, Catherine A

    2017-06-01

    Within the last 10 years there have been significant advances in minimal-access surgery. Although no emerging technology has demonstrated improved outcomes or fewer complications than standard laparoscopy, the introduction of the robotic surgical platform has significantly lowered abdominal hysterectomy rates. While operative time and cost were higher in robotic-assisted procedures when the technology was first introduced, newer studies demonstrate equivalent or improved robotic surgical efficiency with increased experience. Single-port hysterectomy has not improved postoperative pain or subjective cosmetic results. Emerging platforms with flexible, articulating instruments may increase the uptake of single-port procedures including natural orifice transluminal endoscopic cases.

  8. Measurement of a Neutrino-Induced Charged Current Single Neutral Pion Cross Section at MicroBooNE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hackenburg, Ariana

    Micro Booster Neutrino Experiment (MicroBooNE) is a Liquid Argon Time Projection Chamber (LArTPC) operating in the Booster Neutrino Beamline at Fermi National Accelerator Laboratory. MicroBooNE's physics goals include studying short baslinemore » $$\

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Curto, Sergio; Taj-Eldin, Mohammed; Fairchild, Dillon

    Purpose: The relationship between microwave ablation system operating frequency and ablation performance is not currently well understood. The objective of this study was to comparatively assess the differences in microwave ablation at 915 MHz and 2.45 GHz. Methods: Analytical expressions for electromagnetic radiation from point sources were used to compare power deposition at the two frequencies of interest. A 3D electromagnetic-thermal bioheat transfer solver was implemented with the finite element method to characterize power deposition and thermal ablation with asymmetrical insulated dipole antennas (single-antenna and dual-antenna synchronous arrays). Simulation results were validated against experiments in ex vivo tissue. Results: Theoretical,more » computational, and experimental results indicated greater power deposition and larger diameter ablation zones when using a single insulated microwave antenna at 2.45 GHz; experimentally, 32 ± 4.1 mm and 36.3 ± 1.0 mm for 5 and 10 min, respectively, at 2.45 GHz, compared to 24 ± 1.7 mm and 29.5 ± 0.6 mm at 915 MHz, with 30 W forward power at the antenna input port. In experiments, faster heating was observed at locations 5 mm (0.91 vs 0.49 °C/s) and 10 mm (0.28 vs 0.15 °C/s) from the antenna operating at 2.45 GHz. Larger ablation zones were observed with dual-antenna arrays at 2.45 GHz; however, the differences were less pronounced than for single antennas. Conclusions: Single- and dual-antenna arrays systems operating at 2.45 GHz yield larger ablation zone due to greater power deposition in proximity to the antenna, as well as greater role of thermal conduction.« less

  10. STS-66 Space Shuttle mission report

    NASA Technical Reports Server (NTRS)

    Fricke, Robert W., Jr.

    1995-01-01

    The primary objective of this flight was to accomplish complementary science objectives by operating the Atmospheric Laboratory for Applications and Science-3 (ATLAS-3) and the Cryogenic Infrared Spectrometers and Telescopes for the Atmosphere-Shuttle Pallet Satellite (CRISTA-SPAS). The secondary objectives of this flight were to perform the operations of the Shuttle Solar Backscatter Ultraviolet/A (SSBUV/A) payload, the Experiment of the Sun Complementing the Atlas Payload and Education-II (ESCAPE-II) payload, the Physiological and Anatomical Rodent Experiment/National Institutes of Health Rodents (PARE/NIH-R) payload, the Protein Crystal Growth-Thermal Enclosure System (PCG-TES) payload, the Protein Crystal Growth-Single Locker Thermal Enclosure System (PCG-STES), the Space Tissue/National Institutes of Health Cells STL/N -A payload, the Space Acceleration Measurement Systems (SAMS) Experiment, and Heat Pipe Performance Experiment (HPPE) payload. The 11-day plus 2 contingency day STS-66 mission was flown as planned, with no contingency days used for weather avoidance or Orbiter contingency operations. Appendix A lists the sources of data from which this report was prepared, and Appendix B defines all acronyms and abbreviations used in the report.

  11. STS-66 Space Shuttle mission report

    NASA Astrophysics Data System (ADS)

    Fricke, Robert W., Jr.

    1995-02-01

    The primary objective of this flight was to accomplish complementary science objectives by operating the Atmospheric Laboratory for Applications and Science-3 (ATLAS-3) and the Cryogenic Infrared Spectrometers and Telescopes for the Atmosphere-Shuttle Pallet Satellite (CRISTA-SPAS). The secondary objectives of this flight were to perform the operations of the Shuttle Solar Backscatter Ultraviolet/A (SSBUV/A) payload, the Experiment of the Sun Complementing the Atlas Payload and Education-II (ESCAPE-II) payload, the Physiological and Anatomical Rodent Experiment/National Institutes of Health Rodents (PARE/NIH-R) payload, the Protein Crystal Growth-Thermal Enclosure System (PCG-TES) payload, the Protein Crystal Growth-Single Locker Thermal Enclosure System (PCG-STES), the Space Tissue/National Institutes of Health Cells STL/N -A payload, the Space Acceleration Measurement Systems (SAMS) Experiment, and Heat Pipe Performance Experiment (HPPE) payload. The 11-day plus 2 contingency day STS-66 mission was flown as planned, with no contingency days used for weather avoidance or Orbiter contingency operations. Appendix A lists the sources of data from which this report was prepared, and Appendix B defines all acronyms and abbreviations used in the report.

  12. Surgical treatment of chronic pancreatitis using Frey's procedure: a Brazilian 16-year single-centre experience.

    PubMed

    Gestic, Martinho Antonio; Callejas-Neto, Francisco; Chaim, Elinton Adami; Utrini, Murillo Pimentel; Cazzo, Everton; Pareja, Jose Carlos

    2011-04-01

    Surgical treatment of chronic pancreatitis is indicated for intractable pain. Frey's procedure is an accepted treatment for this disease. The aim of the present study was to describe a single-centre experience in the treatment of chronic pancreatitis using Frey's procedure. A retrospective analysis of 73 patients who underwent a Frey's procedure between 1991 to 2007 and had at least 1 year of follow-up. Demographics, indication for surgery, peri-operative complications and late outcomes were analysed. The median age was 39.9 years. Seventy out of the 73 (95.8%) patients were male. The median pre-operative body mass index (BMI) was 19.1 kg/m(2). All patients had abdominal pain, 34 (46.6%) of them daily and 13 (17.8%) weekly, with moderate or severe intensity in 98.6% (n= 72). The aetiology was secondary to alcohol in 70 patients (95.9%), with a median consumption of 278 g per day. The surgical morbidity rate was 28.7%; there were no deaths. Median post-operative follow-up was 77.0 months; 64 patients (91.4%) had complete pain relief and post-operative BMI was 22.4 kg/m(2) (P<0.001). All patients with pre-operative endocrine and exocrine insufficiencies showed no reversal of the situation. New onset insufficiencies appeared late. Frey's procedure was a safe and effective therapeutic option for the surgical treatment of patients with intractable pain caused by chronic pancreatitis. © 2011 International Hepato-Pancreato-Biliary Association.

  13. Maternal Adverse Childhood Experience and Infant Health: Biomedical and Psychosocial Risks as Intermediary Mechanisms.

    PubMed

    Madigan, Sheri; Wade, Mark; Plamondon, Andre; Maguire, Jonathon L; Jenkins, Jennifer M

    2017-08-01

    To assess the mechanisms accounting for the transfer of risk from one generation to the next, especially as they relate to maternal adverse childhood experiences and infant physical and emotional health outcomes. Participants were 501 community mother-infant dyads recruited shortly after the birth and followed up at 18 months. Mothers retrospectively reported on their adverse childhood experiences. The main outcome measures were parent-reported infant physical health and emotional problems. Potential mechanisms of intergenerational transmission included cumulative biomedical risk (eg, prenatal and perinatal complications) and postnatal psychosocial risk (eg, maternal depression, single parenthood, marital conflict). Four or more adverse childhood experiences were related to a 2- and 5-fold increased risk of experiencing any biomedical or psychosocial risk, respectively. There was a linear association between number of adverse childhood experiences and extent of biomedical and psychosocial risk. Path analysis revealed that the association between maternal adverse childhood experiences and infant physical health operated specifically through cumulative biomedical risk, while the relationship between adverse childhood experiences and infant emotional health operated specifically through cumulative psychosocial risk. This pattern was not explained by maternal childhood disadvantage or current neighborhood poverty. Maternal adverse childhood experiences confer vulnerability to prenatal, perinatal, and postnatal psychosocial health. The association between adverse childhood experiences and offspring physical and emotional health operates through discrete intermediary mechanisms. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Will musculoskeletal, visual and psychosocial stress change for visual display unit (VDU) operators when moving from a single-occupancy office to an office landscape?

    PubMed

    Helland, Magne; Horgen, Gunnar; Kvikstad, Tor Martin; Garthus, Tore; Aarås, Arne

    2008-01-01

    This study investigated the effect of moving from single-occupancy offices to a landscape environment. Thirty-two visual display unit (VDU) operators reported no significant change in visual discomfort. Lighting conditions and glare reported subjectively showed no significant correlation with visual discomfort. Experience of pain was found to reduce subjectively rated work capacity during VDU tasks. The correlation between visual discomfort and reduced work capacity for single-occupancy offices was rs=.88 (p=.000) and for office landscape rs=.82 (p=.000). Eye blink rate during habitual VDU work was recorded for 12 operators randomly selected from the 32 participants in the office landscape. A marked drop in eye blink rate during VDU work was found compared to eye blink rate during easy conversation. There were no significant changes in pain intensity in the neck, shoulder, forearm, wrist/hand, back or headache (.24

  15. Strategies for enhanced deammonification performance and reduced nitrous oxide emissions.

    PubMed

    Leix, Carmen; Drewes, Jörg E; Ye, Liu; Koch, Konrad

    2017-07-01

    Deammonification's performance and associated nitrous oxide emissions (N 2 O) depend on operational conditions. While studies have investigated factors for high performances and low emissions separately, this study investigated optimizing deammonification performance while simultaneously reducing N 2 O emissions. Using a design of experiment (DoE) method, two models were developed for the prediction of the nitrogen removal rate and N 2 O emissions during single-stage deammonification considering three operational factors (i.e., pH value, feeding and aeration strategy). The emission factor varied between 0.7±0.5% and 4.1±1.2% at different DoE-conditions. The nitrogen removal rate was predicted to be maximized at settings of pH 7.46, intermittent feeding and aeration. Conversely, emissions were predicted to be minimized at the design edges at pH 7.80, single feeding, and continuous aeration. Results suggested a weak positive correlation between the nitrogen removal rate and N 2 O emissions, thus, a single optimizing operational set-point for maximized performance and minimized emissions did not exist. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Five years' experience at a single centre of craniocerebral injury from winnowing fan blades.

    PubMed

    Kumar, Apoorva; Shankar, Ravi; Pandey, Rajendra P; Keshri, Virendra; Singh, Kulwant; Sharma, Vivek

    2010-02-01

    India, an agriculture-based country, relies heavily on indigenous farm machinery. In our study we present 31 patients with winnowing fan blade head injury, operated on at our centre between 2004 and 2008. The mechanism and nature of the injuries, operative methods, outcome and methods of prevention are discussed with special reference to the occurrence of this type of injury in the pediatric population. Copyright 2009 Elsevier Ltd. All rights reserved.

  17. On-chip III-V monolithic integration of heralded single photon sources and beamsplitters

    NASA Astrophysics Data System (ADS)

    Belhassen, J.; Baboux, F.; Yao, Q.; Amanti, M.; Favero, I.; Lemaître, A.; Kolthammer, W. S.; Walmsley, I. A.; Ducci, S.

    2018-02-01

    We demonstrate a monolithic III-V photonic circuit combining a heralded single photon source with a beamsplitter, at room temperature and telecom wavelength. Pulsed parametric down-conversion in an AlGaAs waveguide generates counterpropagating photons, one of which is used to herald the injection of its twin into the beamsplitter. We use this configuration to implement an integrated Hanbury-Brown and Twiss experiment, yielding a heralded second-order correlation gher(2 )(0 )=0.10 ±0.02 that confirms single-photon operation. The demonstrated generation and manipulation of quantum states on a single III-V semiconductor chip opens promising avenues towards real-world applications in quantum information.

  18. Detoxification of Acetylcholinesterase Inhibitors.

    DTIC Science & Technology

    1987-02-19

    IIB:HB-o Mvse three machanisms can be distinguished by appropriate labelling experiments in oxygen-18 H.O. If mechanism C is operating, hydrolysis...enzyue reveals that there is a single break at pa 6.2 relative to both Vmax and Vfax/Km. This would appear to represent the titration of the basic residue

  19. Destroyer Engineered Operating Cycle (DDEOC), System Maintenance Analysis DDG-37 Class, Salt Water Circulating System SMA 37-106-256, Review of Experience

    DTIC Science & Technology

    1978-07-01

    horizontally mounted, single-end suction, single- stage centrifugal pumps. The rotating elements are mounted on the shaft of the driving motor, and the pump...annual open-and-inspect requirement for MIP E-17/296-21, MRC 21 A14V A. Industrial Facility Improvements -- None IMA Improvements -- None Intergrated ...Circulating Pump, Warren Pumps, Inc., NAVSHIPS 347-3146, January 1959. 4. Technical Manual - Horizontal Close-Co!;pled Pumps Sea (Salt) Water

  20. A LabVIEW-Based Virtual Instrument System for Laser-Induced Fluorescence Spectroscopy.

    PubMed

    Wu, Qijun; Wang, Lufei; Zu, Lily

    2011-01-01

    We report the design and operation of a Virtual Instrument (VI) system based on LabVIEW 2009 for laser-induced fluorescence experiments. This system achieves synchronous control of equipment and acquisition of real-time fluorescence data communicating with a single computer via GPIB, USB, RS232, and parallel ports. The reported VI system can also accomplish data display, saving, and analysis, and printing the results. The VI system performs sequences of operations automatically, and this system has been successfully applied to obtain the excitation and dispersion spectra of α-methylnaphthalene. The reported VI system opens up new possibilities for researchers and increases the efficiency and precision of experiments. The design and operation of the VI system are described in detail in this paper, and the advantages that this system can provide are highlighted.

  1. A LabVIEW-Based Virtual Instrument System for Laser-Induced Fluorescence Spectroscopy

    PubMed Central

    Wu, Qijun; Wang, Lufei; Zu, Lily

    2011-01-01

    We report the design and operation of a Virtual Instrument (VI) system based on LabVIEW 2009 for laser-induced fluorescence experiments. This system achieves synchronous control of equipment and acquisition of real-time fluorescence data communicating with a single computer via GPIB, USB, RS232, and parallel ports. The reported VI system can also accomplish data display, saving, and analysis, and printing the results. The VI system performs sequences of operations automatically, and this system has been successfully applied to obtain the excitation and dispersion spectra of α-methylnaphthalene. The reported VI system opens up new possibilities for researchers and increases the efficiency and precision of experiments. The design and operation of the VI system are described in detail in this paper, and the advantages that this system can provide are highlighted. PMID:22013388

  2. Single-stage revision for fungal peri-prosthetic joint infection: a single-centre experience.

    PubMed

    Klatte, T O; Kendoff, D; Kamath, A F; Jonen, V; Rueger, J M; Frommelt, L; Gebauer, M; Gehrke, T

    2014-04-01

    Fungal peri-prosthetic infections of the knee and hip are rare but likely to result in devastating complications. In this study we evaluated the results of their management using a single-stage exchange technique. Between 2001 and 2011, 14 patients (ten hips, four knees) were treated for a peri-prosthetic fungal infection. One patient was excluded because revision surgery was not possible owing to a large acetabular defect. One patient developed a further infection two months post-operatively and was excluded from the analysis. Two patients died of unrelated causes. After a mean of seven years (3 to 11) a total of ten patients were available for follow-up. One patient, undergoing revision replacement of the hip, had a post-operative dislocation. Another patient, undergoing revision replacement of the knee, developed a wound infection and required revision 29 months post-operatively following a peri-prosthetic femoral fracture. The mean Harris hip score increased to 74 points (63 to 84; p < 0.02) in those undergoing revision replacement of the hip, and the mean Hospital for Special Surgery knee score increased to 75 points (70 to 80; p < 0.01) in those undergoing revision replacement of the knee. A single-stage revision following fungal peri-prosthetic infection is feasible, with an acceptable rate of a satisfactory outcome.

  3. The Small Aircraft Transportation System Higher Volume Operations (SATS HVO) Flight Experiment

    NASA Technical Reports Server (NTRS)

    Williams, Daniel M.; Murdoch, Jennifer L.; Adams, Catherine H.

    2005-01-01

    This paper provides a summary of conclusions from the Small Aircraft Transportation System (SATS) Higher Volume Operations (HVO) Flight Experiment which NASA conducted to determine pilot acceptability of the HVO concept for normal conditions. The SATS HVO concept improves efficiency at non-towered, non-radar airports in Instrument Meteorological Conditions (IMC) while achieving a level of safety equal to today s system. Reported are results from flight experiment data that indicate that the SATS HVO concept is viable. The success of the SATS HVO concept is based on acceptable pilot workload, performance, and subjective criteria when compared to the procedural control operations in use today at non-towered, non-radar controlled airfields in IMC. The HVO Flight Experiment, flown on NASA's Cirrus SR22, used a subset of the HVO Simulation Experiment scenarios and evaluation pilots in order to validate the simulation experiment results. HVO and Baseline (today s system) scenarios flown included: single aircraft arriving for a GPS non-precision approach; aircraft arriving for the approach with multiple traffic aircraft; and aircraft arriving for the approach with multiple traffic aircraft and then conducting a missed approach. Results reveal that all twelve low-time instrument-rated pilots preferred SATS HVO when compared to current procedural separation operations. These pilots also flew the HVO procedures safely and proficiently without additional workload in comparison to today s system (Baseline). Detailed results of pilot flight technical error, and their subjective assessments of workload and situation awareness are presented in this paper.

  4. SYNCHROTRON RADIATION, FREE ELECTRON LASER, APPLICATION OF NUCLEAR TECHNOLOGY, ETC.: Operating the SDUV-FEL with the echo-enabled harmonic generation scheme

    NASA Astrophysics Data System (ADS)

    Chen, Jian-Hui; Deng, Hai-Xiao; Gu, Qiang; Li, Dong-Guo; Wang, Dong; Zhang, Meng; Zhao, Zhen-Tang

    2009-08-01

    Using the recently proposed echo-enabled harmonic generation (EEHG) free-electron laser (FEL) scheme, it is shown that operating the Shanghai deep ultraviolet FEL (SDUV-FEL) with single-stage to higher harmonics is very promising, with higher frequency up-conversion efficiency, higher harmonic selectivity and lower power requirement of the seed laser. The considerations on a proof-of-principle experiment and expected performance in SDUV-FEL are given.

  5. SEE induced in SRAM operating in a superconducting electron linear accelerator environment

    NASA Astrophysics Data System (ADS)

    Makowski, D.; Mukherjee, Bhaskar; Grecki, M.; Simrock, Stefan

    2005-02-01

    Strong fields of bremsstrahlung photons and photoneutrons are produced during the operation of high-energy electron linacs. Therefore, a mixed gamma and neutron radiation field dominates the accelerators environment. The gamma radiation induced Total Ionizing Dose (TID) effect manifests the long-term deterioration of the electronic devices operating in accelerator environment. On the other hand, the neutron radiation is responsible for Single Event Effects (SEE) and may cause a temporal loss of functionality of electronic systems. This phenomenon is known as Single Event Upset (SEU). The neutron dose (KERMA) was used to scale the neutron induced SEU in the SRAM chips. Hence, in order to estimate the neutron KERMA conversion factor for Silicon (Si), dedicated calibration experiments using an Americium-Beryllium (241Am/Be) neutron standard source was carried out. Single Event Upset (SEU) influences the short-term operation of SRAM compared to the gamma induced TID effect. We are at present investigating the feasibility of an SRAM based real-time beam-loss monitor for high-energy accelerators utilizing the SEU caused by fast neutrons. This paper highlights the effects of gamma and neutron radiations on Static Random Access Memory (SRAM), placed at selected locations near the Superconducting Linear Accelerator driving the Vacuum UV Free Electron Laser (VUVFEL) of DESY.

  6. Blunt hepatic and splenic trauma. A single Center experience using a multidisciplinary protocol.

    PubMed

    Ruscelli, Paolo; Buccoliero, Farncesco; Mazzocato, Susanna; Belfiori, Giulio; Rabuini, Claudio; Sperti, Pierluigi; Rimini, Massimiliano

    2017-01-01

    The aim of this retrospective study was to describe more than 10 years experience of a single Trauma Center about non operative management of abdominal organ injuries in hemodynamically stable patients MATERIAL OF STUDY: Between January 2001 and December 2014 ,732 consecutive patients were admitted with blunt abdominal trauma, involving liver and/or spleen and/or kidney, at the Bufalini Cesena Hospital .Management of patients included a specific institutional developed protocol :hemodynamic stability was evaluated in shock room according to the patients response to fluid challenge and the patients were classified into three categories A,B,and C. Form 732 Trauma, 356(48.6%) of patients were submitted to a surgical procedure, all the other patient 376(51.4%) underwent an non operative management .Overall mortality was 9.8% (72), mortality in the surgery group was 15.4% eheras in the non operative group was 4.5%; the relative risk of mortality, measured by the odds ratio waith a 95% confidence interval, was 3.417(2.023-5.772) for rhe surgery group; patient over 40 years old has a statistically significant higher mortality. In our series the overall mortality rate of non operative management group was 4.5%, instead in unstable patients, the surgery group, the mortality was 15.3%; the overall mortality mortality rate after the application of our protocol is 9.8%, Although surgery continues to be the standard for hemodically unstable patients with blunt hepatic and splenic trauma. In our experience AAST Organ Injury Scale was useless for the therapeutic decision making process after the CT scan if a source of bleeding was detected and immediate angiography was performed in order to control and solve it. In our experience the AAST Organ Injury Scale was useless for the therapeutic decision making process, The results suggest that the only criteria of choice for therapeutici strategy was the hemodynamic stability, Nonoperative managem,ent can be applied only following strict institutional criteria KEY WORDS: Hemodynmic stability, Nonoperative management, Trauma.

  7. ESR Experiments on a Single Donor Electron in Isotopically Enriched Silicon

    NASA Astrophysics Data System (ADS)

    Tracy, Lisa; Luhman, Dwight; Carr, Stephen; Borchardt, John; Bishop, Nathaniel; Ten Eyck, Gregory; Pluym, Tammy; Wendt, Joel; Witzel, Wayne; Blume-Kohout, Robin; Nielsen, Erik; Lilly, Michael; Carroll, Malcolm

    In this talk we will discuss electron spin resonance experiments in single donor silicon qubit devices fabricated at Sandia National Labs. A self-aligned device structure consisting of a polysilicon gate SET located adjacent to the donor is used for donor electron spin readout. Using a cryogenic HEMT amplifier next to the silicon device, we demonstrate spin readout at 100 kHz bandwidth and Rabi oscillations with 0.96 visibility. Electron spin resonance measurements on these devices show a linewidth of 30 kHz and coherence times T2* = 10 us and T2 = 0.3 ms. We also discuss estimates of the fidelity of our donor electron spin qubit measurements using gate set tomography. This work was performed, in part, at the Center for Integrated Nanotechnologies, a U.S. DOE Office of Basic Energy Sciences user facility. Sandia National Laboratories is a multi-program laboratory operated by Sandia Corporation, a Lockheed-Martin Company, for the U. S. Department of Energy under Contract No. DE-AC04-94AL85000. ESR Experiments on a Single Donor Electron in Isotopically Enriched Silicon.

  8. Transumbilical single port laparoscopic surgery for the treatment of concomitant disease.

    PubMed

    Lee, Jun Suh; Hong, Tae Ho; Park, Byung Joon; Kim, Jin Jo

    2013-06-01

    We report our experience of transumbilical single port laparoscopic surgery (TUSPLS) for multiple concomitant intraabdominal pathologies, and assess the feasibility of this technique with several technical tips. Various combined procedures using TUSPLS were performed since April, 2008. All records of concomitant laparoscopic procedures using TUSPLS were searched at three hospitals. Forty-one patients underwent 82 combined procedures using TUSPLS in a single session. The perioperative outcomes of simultaneously performed cholecystectomy and ovarian cystectomy using TUSPLS (n = 14) are compared with those of using CLS (n = 11). The operating time was significantly longer with the TUSPLS method than with the CLS method. However, postoperative convalescent outcomes such as postoperative hospital stay, VAS pain score, and required analgesics showed no differences between the two methods. Also, there were no significant operative complications associated with the two methods. Fewer trocars were used with the TUSPLS method. Combined laparoscopic procedures for various concomitant pathologies in the abdomen can be performed using transumbilical single port laparoscopic surgery without increasing morbidity or hospital stay in patients with acceptable risk.

  9. Arithmetic Practice Can Be Modified to Promote Understanding of Mathematical Equivalence

    ERIC Educational Resources Information Center

    McNeil, Nicole M.; Fyfe, Emily R.; Dunwiddie, April E.

    2015-01-01

    This experiment tested if a modified version of arithmetic practice facilitates understanding of math equivalence. Children within 2nd-grade classrooms (N = 166) were randomly assigned to practice single-digit addition facts using 1 of 2 workbooks. In the control workbook, problems were presented in the traditional "operations = answer"…

  10. Automatic Rejection Of Multimode Laser Pulses

    NASA Technical Reports Server (NTRS)

    Tratt, David M.; Menzies, Robert T.; Esproles, Carlos

    1991-01-01

    Characteristic modulation detected, enabling rejection of multimode signals. Monitoring circuit senses multiple longitudinal mode oscillation of transversely excited, atmospheric-pressure (TEA) CO2 laser. Facility developed for inclusion into coherent detection laser radar (LIDAR) system. However, circuit described of use in any experiment where desireable to record data only when laser operates in single longitudinal mode.

  11. Chicago Mothers on Finding and Using Child Care during Nonstandard Work Hours

    ERIC Educational Resources Information Center

    Stoll, Marcia; Alexander, David; Nicpon, Christine

    2015-01-01

    Few issues confound child care policy more than the fact that very large numbers of mothers work evenings, overnight, or weekend hours when fewer child care programs operate. The authors interviewed 50 single Chicago mothers with nontraditional work hours about their experiences finding and using child care. Participants' responses addressed…

  12. Simple gas chromatographic system for analysis of microbial respiratory gases

    NASA Technical Reports Server (NTRS)

    Carle, G. C.

    1972-01-01

    Dual column ambient temperature system, consisting of pair of capillary columns, microbead thermistor detector and micro gas-sampling valve, is used in remote life-detection equipment for space experiments. Performance outweighs advantage gained by utilizing single-column systems to reduce weight, conserve carrier gas and operate at lower power levels.

  13. De-aliasing for signal restoration in Propeller MR imaging.

    PubMed

    Chiu, Su-Chin; Chang, Hing-Chiu; Chu, Mei-Lan; Wu, Ming-Long; Chung, Hsiao-Wen; Lin, Yi-Ru

    2017-02-01

    Objects falling outside of the true elliptical field-of-view (FOV) in Propeller imaging show unique aliasing artifacts. This study proposes a de-aliasing approach to restore the signal intensities in Propeller images without extra data acquisition. Computer simulation was performed on the Shepp-Logan head phantom deliberately placed obliquely to examine the signal aliasing. In addition, phantom and human imaging experiments were performed using Propeller imaging with various readouts on a 3.0 Tesla MR scanner. De-aliasing using the proposed method was then performed, with the first low-resolution single-blade image used to find out the aliasing patterns in all the single-blade images, followed by standard Propeller reconstruction. The Propeller images without and with de-aliasing were compared. Computer simulations showed signal loss at the image corners along with aliasing artifacts distributed along directions corresponding to the rotational blades, consistent with clinical observations. The proposed de-aliasing operation successfully restored the correct images in both phantom and human experiments. The de-aliasing operation is an effective adjunct to Propeller MR image reconstruction for retrospective restoration of aliased signals. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. The impact of days off between cases on perioperative outcomes for robotic-assisted laparoscopic prostatectomy.

    PubMed

    Pearce, Shane M; Pariser, Joseph J; Patel, Sanjay G; Anderson, Blake B; Eggener, Scott E; Zagaja, Gregory P

    2016-02-01

    To examine the effect of days off between cases on perioperative outcomes for robotic-assisted laparoscopic prostatectomy (RALP). We analyzed a single-surgeon series of 2036 RALP cases between 2003 and 2014. Days between cases (DBC) was calculated as the number of days elapsed since the surgeon's previous RALP with the second start cases assigned 0 DBC. Surgeon experience was assessed by dividing sequential case experience into cases 0-99, cases 100-249, cases 250-999, and cases 1000+ based on previously reported learning curve data for RALP. Outcomes included estimated blood loss (EBL), operative time (OT), and positive surgical margins (PSMs). Multiple linear regression was used to assess the impact of the DBC and surgeon experience on EBL, OT, and PSM, while controlling for patient characteristics, surgical technique, and pathologic variables. Overall median DBC was 1 day (0-3) and declined with increasing surgeon case experience. Multiple linear regression demonstrated that each additional DBC was independently associated with increased EBL [β = 3.7, 95% CI (1.3-6.2), p < 0.01] and OT [β = 2.3 (1.4-3.2), p < 0.01], but was not associated with rate of PSM [β = 0.004 (-0.003-0.010), p = 0.2]. Increased experience was also associated with reductions in EBL and OT (p < 0.01). Surgeon experience of 1000+ cases was associated with a 10% reduction in PSM rate (p = 0.03) compared to cases 0-99. In a large single-surgeon RALP series, DBC was associated with increased blood loss and operative time, but not associated with positive surgical margins, when controlling for surgeon experience.

  15. Learning curve of robot-assisted laparoscopic radical prostatectomy for a single experienced surgeon: comparison with simultaneous laparoscopic radical prostatectomy.

    PubMed

    Ku, Ja Yoon; Ha, Hong Koo

    2015-04-01

    Despite the large number of analytical reports regarding the learning curve in the transition from open to robot-assisted radical prostatectomy (RARP), few comparative results with laparoscopic radical prostatectomy (LRP) have been reported. Thus, we evaluated operative and postoperative outcomes in RARP versus 100 simultaneously performed LRPs. A single surgeon had performed more than 1,000 laparoscopic operations, including 415 cases of radical nephrectomy, 85 radical cystectomies, 369 radical prostatectomies, and treatment of 212 other urological tumors, since 2009. We evaluated operative (operation time, intraoperative transfusion, complications, hospital stay, margin status, pathological stage, Gleason score) and postoperative (continence and erectile function) parameters in initial cases of RARP without tutoring compared with 100 recently performed LRPs. Mean operation time and length of hospital stay for RARP and LRP were 145.5±43.6 minutes and 118.1±39.1 minutes, and 6.4±0.9 days and 6.6±1.1 days, respectively (p=0.003 and p=0.721). After 17 cases, the mean operation time for RARP was similar to LRP (less than 2 hours). Positive surgical margins in localized cancer were seen in 11.1% and 8.9% of cases in RARP and LRP, respectively (p=0.733). At postoperative 3 months, sexual intercourse was reported in 14.0% and 12.0%, and pad-free continence in 96.0% and 81.0% in patients with RARP and LRP, respectively (p=0.796 and p=0.012). Previous large-volume experience of LRPs may shorten the learning curve for RARP in terms of oncological outcome. Additionally, previous experience with laparoscopy may improve the functional outcomes of RARP.

  16. Hand-held computer operating system program for collection of resident experience data.

    PubMed

    Malan, T K; Haffner, W H; Armstrong, A Y; Satin, A J

    2000-11-01

    To describe a system for recording resident experience involving hand-held computers with the Palm Operating System (3 Com, Inc., Santa Clara, CA). Hand-held personal computers (PCs) are popular, easy to use, inexpensive, portable, and can share data among other operating systems. Residents in our program carry individual hand-held database computers to record Residency Review Committee (RRC) reportable patient encounters. Each resident's data is transferred to a single central relational database compatible with Microsoft Access (Microsoft Corporation, Redmond, WA). Patient data entry and subsequent transfer to a central database is accomplished with commercially available software that requires minimal computer expertise to implement and maintain. The central database can then be used for statistical analysis or to create required RRC resident experience reports. As a result, the data collection and transfer process takes less time for residents and program director alike, than paper-based or central computer-based systems. The system of collecting resident encounter data using hand-held computers with the Palm Operating System is easy to use, relatively inexpensive, accurate, and secure. The user-friendly system provides prompt, complete, and accurate data, enhancing the education of residents while facilitating the job of the program director.

  17. Robotic-assisted single-port donor nephrectomy using the da Vinci single-site platform.

    PubMed

    LaMattina, John C; Alvarez-Casas, Josue; Lu, Irene; Powell, Jessica M; Sultan, Samuel; Phelan, Michael W; Barth, Rolf N

    2018-02-01

    Although single-port donor nephrectomy offers improved cosmetic outcomes, technical challenges have limited its application to selected centers. Our center has performed over 400 single-port donor nephrectomies. The da Vinci single-site robotic platform was utilized in an effort to overcome the steric, visualization, ergonomic, and other technical limitations associated with the single-port approach. Food and Drug Administration device exemption was obtained. Selection criteria for kidney donation included body mass index <35, left kidney donors, and ≤2 renal arteries. After colonic mobilization using standard single-port techniques, the robotic approach was utilized for ureteral complex and hilar dissection. Three cases were performed using the robotic single-site platform. Average total operative time was 262 ± 42 min including 82 ± 16 min of robotic use. Docking time took 20 ± 10 min. Blood loss averaged 77 ± 64 mL. No intraoperative complications occurred, and all procedures were completed with our standard laparoscopic single-port approach. This is the first clinical experience of robotic-assisted donor nephrectomy utilizing the da Vinci single-site platform. Our experience supported the safety of this approach but found that the technology added cost and complexity without tangible benefit. Development of articulating instruments, energy, and stapling devices will be necessary for increased application of robotic single-site surgery for donor nephrectomy. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Gatemon Benchmarking and Two-Qubit Operation

    NASA Astrophysics Data System (ADS)

    Casparis, Lucas; Larsen, Thorvald; Olsen, Michael; Petersson, Karl; Kuemmeth, Ferdinand; Krogstrup, Peter; Nygard, Jesper; Marcus, Charles

    Recent experiments have demonstrated superconducting transmon qubits with semiconductor nanowire Josephson junctions. These hybrid gatemon qubits utilize field effect tunability singular to semiconductors to allow complete qubit control using gate voltages, potentially a technological advantage over conventional flux-controlled transmons. Here, we present experiments with a two-qubit gatemon circuit. We characterize qubit coherence and stability and use randomized benchmarking to demonstrate single-qubit gate errors of ~0.5 % for all gates, including voltage-controlled Z rotations. We show coherent capacitive coupling between two gatemons and coherent SWAP operations. Finally, we perform a two-qubit controlled-phase gate with an estimated fidelity of ~91 %, demonstrating the potential of gatemon qubits for building scalable quantum processors. We acknowledge financial support from Microsoft Project Q and the Danish National Research Foundation.

  19. One size fits all? Mixed methods evaluation of the impact of 100% single-room accommodation on staff and patient experience, safety and costs

    PubMed Central

    Maben, Jill; Penfold, Clarissa; Simon, Michael; Anderson, Janet E; Robert, Glenn; Pizzo, Elena; Hughes, Jane; Murrells, Trevor; Barlow, James

    2016-01-01

    Background and objectives There is little strong evidence relating to the impact of single-room accommodation on healthcare quality and safety. We explore the impact of all single rooms on staff and patient experience; safety outcomes; and costs. Methods Mixed methods pre/post ‘move’ comparison within four nested case study wards in a single acute hospital with 100% single rooms; quasi-experimental before-and-after study with two control hospitals; analysis of capital and operational costs associated with single rooms. Results Two-thirds of patients expressed a preference for single rooms with comfort and control outweighing any disadvantages (sense of isolation) felt by some. Patients appreciated privacy, confidentiality and flexibility for visitors afforded by single rooms. Staff perceived improvements (patient comfort and confidentiality), but single rooms were worse for visibility, surveillance, teamwork, monitoring and keeping patients safe. Staff walking distances increased significantly post move. A temporary increase of falls and medication errors in one ward was likely to be associated with the need to adjust work patterns rather than associated with single rooms per se. We found no evidence that single rooms reduced infection rates. Building an all single-room hospital can cost 5% more with higher housekeeping and cleaning costs but the difference is marginal over time. Conclusions Staff needed to adapt their working practices significantly and felt unprepared for new ways of working with potentially significant implications for the nature of teamwork in the longer term. Staff preference remained for a mix of single rooms and bays. Patients preferred single rooms. PMID:26408568

  20. Image dependency in the recognition of newly learnt faces.

    PubMed

    Longmore, Christopher A; Santos, Isabel M; Silva, Carlos F; Hall, Abi; Faloyin, Dipo; Little, Emily

    2017-05-01

    Research investigating the effect of lighting and viewpoint changes on unfamiliar and newly learnt faces has revealed that such recognition is highly image dependent and that changes in either of these leads to poor recognition accuracy. Three experiments are reported to extend these findings by examining the effect of apparent age on the recognition of newly learnt faces. Experiment 1 investigated the ability to generalize to novel ages of a face after learning a single image. It was found that recognition was best for the learnt image with performance falling the greater the dissimilarity between the study and test images. Experiments 2 and 3 examined whether learning two images aids subsequent recognition of a novel image. The results indicated that interpolation between two studied images (Experiment 2) provided some additional benefit over learning a single view, but that this did not extend to extrapolation (Experiment 3). The results from all studies suggest that recognition was driven primarily by pictorial codes and that the recognition of faces learnt from a limited number of sources operates on stored images of faces as opposed to more abstract, structural, representations.

  1. Learning curve of transumbilical single incision laparoscopic cholecystectomy (SILS): a preliminary study of 80 selected patients with benign gallbladder diseases.

    PubMed

    Qiu, Zhengjun; Sun, Jing; Pu, Ying; Jiang, Tao; Cao, Jun; Wu, Weidong

    2011-09-01

    Transumbilical single incision laparoscopic surgery (SILS) is a new laparoscopic procedure in which only one transumbilical incision is made, demonstrated as a scarless procedure. Here we report a single-center preliminary experience of transumbilical single incision laparoscopic cholecystectomy (SILC) in the treatment of benign gallbladder diseases, defining a single surgeon's learning curve. A total of 80 patients underwent SILC successfully by a single experienced laparoscopic surgeon. The operation was performed following the routine LC procedure. Then the perioperative demographics were recorded and the operative time was used to define the learning curve. The study group included 27 male and 53 female patients with gallstones (56 cases), cholesterol polyps (16 cases), an adenomatous polyp (3 cases), adenomyomatosis (1 case), or complex diseases (4 cases), and all consented to undergo SILC. No patient was converted to normal LC or open surgery. There were no perioperative port-related or surgical complications. The average operative time was 46.9 ± 14.6 min. The average postoperative hospital stay was 1.8 ± 1.3 days. The learning curve of the SILC procedures for this series of selected patients confirmed that SILC is a feasible, safe, and effective approach to the treatment of benign gallbladder diseases. For experienced laparoscopic surgeons, SILC is an easy and safe procedure. Patients benefit from milder pain, a lower incidence of port-related complications, better cosmesis, and fast recovery. The SILC procedure may become another option for the treatment of benign gallbladder diseases for selected patients.

  2. Evaluation of accuracy in implant site preparation performed in single- or multi-step drilling procedures.

    PubMed

    Marheineke, Nadine; Scherer, Uta; Rücker, Martin; von See, Constantin; Rahlf, Björn; Gellrich, Nils-Claudius; Stoetzer, Marcus

    2018-06-01

    Dental implant failure and insufficient osseointegration are proven results of mechanical and thermal damage during the surgery process. We herein performed a comparative study of a less invasive single-step drilling preparation protocol and a conventional multiple drilling sequence. Accuracy of drilling holes was precisely analyzed and the influence of different levels of expertise of the handlers and additional use of drill template guidance was evaluated. Six experimental groups, deployed in an osseous study model, were representing template-guided and freehanded drilling actions in a stepwise drilling procedure in comparison to a single-drill protocol. Each experimental condition was studied by the drilling actions of respectively three persons without surgical knowledge as well as three highly experienced oral surgeons. Drilling actions were performed and diameters were recorded with a precision measuring instrument. Less experienced operators were able to significantly increase the drilling accuracy using a guiding template, especially when multi-step preparations are performed. Improved accuracy without template guidance was observed when experienced operators were executing single-step versus multi-step technique. Single-step drilling protocols have shown to produce more accurate results than multi-step procedures. The outcome of any protocol can be further improved by use of guiding templates. Operator experience can be a contributing factor. Single-step preparations are less invasive and are promoting osseointegration. Even highly experienced surgeons are achieving higher levels of accuracy by combining this technique with template guidance. Hereby template guidance enables a reduction of hands-on time and side effects during surgery and lead to a more predictable clinical diameter.

  3. Transvaginal laparoscopically assisted endoscopic cholecystectomy: preliminary clinical results for a series of 43 cases in China.

    PubMed

    Niu, Jun; Song, Wei; Yan, Ming; Fan, Wei; Niu, Weibo; Liu, Enyu; Peng, Cheng; Lin, Pengfei; Li, Peng; Khan, Abdul Qadir

    2011-04-01

    Transvaginal cholecystectomy has been performed successfully at several research institutions worldwide using natural orifice transluminal endoscopic surgery (NOTES) techniques. However, it is a growing new surgical concept in China. Several technical challenges hinder the safe clinical application of NOTES. This study investigated transvaginal endoscopic cholecystectomy performed with the assistance of a single umbilical trocar and achieved helpful initial clinical experience. From May 2009 to April 2010, a total of 43 transvaginal human cholecystectomies were performed. A single umbilical trocar was used for safe access and laparoscopic assistance during the operation. After the gallbladder had been removed through the vagina, the colpotomy was closed with absorbable stitches under direct vision. In addition, Student's t-test was performed for two samples to estimate the superiority of NOTES over a conventional laparoscopic cholecystectomy (LC) operation. The procedure was successfully completed for all the patients. No intra- or post-operative complications occurred. The patients recovered promptly after surgery, and all were satisfied with ideal cosmetic outcomes. The postoperative pain, hospital stay, and cost of hospitalization with NOTES were much less than with conventional LC operations. Although endoscopic instruments specifically designed for NOTES are not available, the addition of an umbilical trocar is an optimal way to allow safe performance of NOTES procedures in an easily reproducible manner. The authors' initial experience demonstrates that this hybrid technique is potentially feasible and effective for reducing postoperative pain and recovery times while improving the cosmetic results of transvaginal cholecystectomy.

  4. Performance Assessment of Single Electrode-Supported Solid Oxide Cells Operating in the Steam Electrolysis Mode

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    X. Zhang; J. E. O'Brien; R. C. O'Brien

    2011-11-01

    An experimental study is under way to assess the performance of electrode-supported solid-oxide cells operating in the steam electrolysis mode for hydrogen production. Results presented in this paper were obtained from single cells, with an active area of 16 cm{sup 2} per cell. The electrolysis cells are electrode-supported, with yttria-stabilized zirconia (YSZ) electrolytes ({approx}10 {mu}m thick), nickel-YSZ steam/hydrogen electrodes ({approx}1400 {mu}m thick), and modified LSM or LSCF air-side electrodes ({approx}90 {mu}m thick). The purpose of the present study is to document and compare the performance and degradation rates of these cells in the fuel cell mode and in the electrolysismore » mode under various operating conditions. Initial performance was documented through a series of voltage-current (VI) sweeps and AC impedance spectroscopy measurements. Degradation was determined through long-term testing, first in the fuel cell mode, then in the electrolysis mode. Results generally indicate accelerated degradation rates in the electrolysis mode compared to the fuel cell mode, possibly due to electrode delamination. The paper also includes details of an improved single-cell test apparatus developed specifically for these experiments.« less

  5. Results from phase 1 of the HAYSTAC microwave cavity axion experiment

    NASA Astrophysics Data System (ADS)

    Zhong, L.; Al Kenany, S.; Backes, K. M.; Brubaker, B. M.; Cahn, S. B.; Carosi, G.; Gurevich, Y. V.; Kindel, W. F.; Lamoreaux, S. K.; Lehnert, K. W.; Lewis, S. M.; Malnou, M.; Maruyama, R. H.; Palken, D. A.; Rapidis, N. M.; Root, J. R.; Simanovskaia, M.; Shokair, T. M.; Speller, D. H.; Urdinaran, I.; van Bibber, K. A.

    2018-05-01

    We report on the results from a search for dark matter axions with the HAYSTAC experiment using a microwave cavity detector at frequencies between 5.6 and 5.8 GHz. We exclude axion models with two photon coupling ga γ γ≳2 ×10-14 GeV-1 , a factor of 2.7 above the benchmark KSVZ model over the mass range 23.15

  6. Spacecraft platform cost estimating relationships

    NASA Technical Reports Server (NTRS)

    Gruhl, W. M.

    1972-01-01

    The three main cost areas of unmanned satellite development are discussed. The areas are identified as: (1) the spacecraft platform (SCP), (2) the payload or experiments, and (3) the postlaunch ground equipment and operations. The SCP normally accounts for over half of the total project cost and accurate estimates of SCP costs are required early in project planning as a basis for determining total project budget requirements. The development of single formula SCP cost estimating relationships (CER) from readily available data by statistical linear regression analysis is described. The advantages of single formula CER are presented.

  7. Silicon Photonics Transmitter with SOA and Semiconductor Mode-Locked Laser.

    PubMed

    Moscoso-Mártir, Alvaro; Müller, Juliana; Hauck, Johannes; Chimot, Nicolas; Setter, Rony; Badihi, Avner; Rasmussen, Daniel E; Garreau, Alexandre; Nielsen, Mads; Islamova, Elmira; Romero-García, Sebastián; Shen, Bin; Sandomirsky, Anna; Rockman, Sylvie; Li, Chao; Sharif Azadeh, Saeed; Lo, Guo-Qiang; Mentovich, Elad; Merget, Florian; Lelarge, François; Witzens, Jeremy

    2017-10-24

    We experimentally investigate an optical link relying on silicon photonics transmitter and receiver components as well as a single section semiconductor mode-locked laser as a light source and a semiconductor optical amplifier for signal amplification. A transmitter based on a silicon photonics resonant ring modulator, an external single section mode-locked laser and an external semiconductor optical amplifier operated together with a standard receiver reliably supports 14 Gbps on-off keying signaling with a signal quality factor better than 7 for 8 consecutive comb lines, as well as 25 Gbps signaling with a signal quality factor better than 7 for one isolated comb line, both without forward error correction. Resonant ring modulators and Germanium waveguide photodetectors are further hybridly integrated with chip scale driver and receiver electronics, and their co-operability tested. These experiments will serve as the basis for assessing the feasibility of a silicon photonics wavelength division multiplexed link relying on a single section mode-locked laser as a multi-carrier light source.

  8. The work of titin protein folding as a major driver in muscle contraction

    PubMed Central

    Eckels, Edward C.; Tapia-Rojo, Rafael; Rivas-Pardo, Jamie Andrés; Fernández, Julio M.

    2018-01-01

    Single molecule atomic force microscopy and magnetic tweezers experiments have demonstrated that titin Ig domains are capable of folding against a pulling force, generating mechanical work which exceeds that produced by a myosin motor. We hypothesize that upon muscle activation, formation of actomyosin crossbridges reduces the force on titin causing entropic recoil of the titin polymer and triggering the folding of the titin Ig domains. In the physiological force range of 4–15 pN under which titin operates in muscle, the folding contraction of a single Ig domain can generate 200% of the work of entropic recoil, and occurs at forces which exceed the maximum stalling force of single myosin motors. Thus titin operates like a mechanical battery storing elastic energy efficiently by unfolding Ig domains, and delivering the charge back by folding when the motors are activated during a contraction. We advance the hypothesis that titin folding and myosin activation act as inextricable partners during muscle contraction. PMID:29433413

  9. Mentoring console improves collaboration and teaching in surgical robotics.

    PubMed

    Hanly, Eric J; Miller, Brian E; Kumar, Rajesh; Hasser, Christopher J; Coste-Maniere, Eve; Talamini, Mark A; Aurora, Alexander A; Schenkman, Noah S; Marohn, Michael R

    2006-10-01

    One of the most significant limitations of surgical robots has been their inability to allow multiple surgeons and surgeons-in-training to engage in collaborative control of robotic surgical instruments. We report the initial experience with a novel two-headed da Vinci surgical robot that has two collaborative modes: the "swap" mode allows two surgeons to simultaneously operate and actively swap control of the robot's four arms, and the "nudge" mode allows them to share control of two of the robot's arms. The utility of the mentoring console operating in its two collaborative modes was evaluated through a combination of dry laboratory exercises and animal laboratory surgery. The results from surgeon-resident collaborative performance of complex three-handed surgical tasks were compared to results from single-surgeon and single-resident performance. Statistical significance was determined using Student's t-test. Collaborative surgeon-resident swap control reduced the time to completion of complex three-handed surgical tasks by 25% compared to single-surgeon operation of a four-armed da Vinci (P < 0.01) and by 34% compared to single-resident operation (P < 0.001). While swap mode was found to be most helpful during parts of surgical procedures that require multiple hands (such as isolation and division of vessels), nudge mode was particularly useful for guiding a resident's hands during crucially precise steps of an operation (such as proper placement of stitches). The da Vinci mentoring console greatly facilitates surgeon collaboration during robotic surgery and improves the performance of complex surgical tasks. The mentoring console has the potential to improve resident participation in surgical robotics cases, enhance resident education in surgical training programs engaged in surgical robotics, and improve patient safety during robotic surgery.

  10. Deployment of precise and robust sensors on board ISS-for scientific experiments and for operation of the station.

    PubMed

    Stenzel, Christian

    2016-09-01

    The International Space Station (ISS) is the largest technical vehicle ever built by mankind. It provides a living area for six astronauts and also represents a laboratory in which scientific experiments are conducted in an extraordinary environment. The deployed sensor technology contributes significantly to the operational and scientific success of the station. The sensors on board the ISS can be thereby classified into two categories which differ significantly in their key features: (1) sensors related to crew and station health, and (2) sensors to provide specific measurements in research facilities. The operation of the station requires robust, long-term stable and reliable sensors, since they assure the survival of the astronauts and the intactness of the station. Recently, a wireless sensor network for measuring environmental parameters like temperature, pressure, and humidity was established and its function could be successfully verified over several months. Such a network enhances the operational reliability and stability for monitoring these critical parameters compared to single sensors. The sensors which are implemented into the research facilities have to fulfil other objectives. The high performance of the scientific experiments that are conducted in different research facilities on-board demands the perfect embedding of the sensor in the respective instrumental setup which forms the complete measurement chain. It is shown that the performance of the single sensor alone does not determine the success of the measurement task; moreover, the synergy between different sensors and actuators as well as appropriate sample taking, followed by an appropriate sample preparation play an essential role. The application in a space environment adds additional challenges to the sensor technology, for example the necessity for miniaturisation, automation, reliability, and long-term operation. An alternative is the repetitive calibration of the sensors. This approach, however, increases the operational overhead significantly. But meeting especially these requirements offers unique opportunities for testing these sensor technologies in harsh and dedicated environments which are not available on Earth, therefore pushing the related technologies and methodologies to their limits. The scientific objectives for selected experiments, representing a wide range of research fields, are presented, including the instrument setups and the implemented sensor technologies, and where available, the first scientific results are presented.

  11. Multi-institutional Experience in Laparoendoscopic Single-site Surgery (LESS): For Major Extirpative and Reconstructive Procedures in Pediatric Urology.

    PubMed

    Gor, Ronak A; Long, Christopher J; Shukla, Aseem R; Kirsch, Andrew J; Perez-Brayfield, Marcos; Srinivasan, Arun K

    2016-02-01

    To review peri-procedural outcomes from a large, multi-institutional series of pediatric urology patients treated with laparaendoscopic single-site surgery (LESS) for major extirpative and reconstructive procedures. Consecutive LESS cases between January 2011 and May 2014 from three free-standing pediatric referral centers were reviewed. Data include age, sex, operative time, blood loss, length of stay, and complications according to the modified Clavien-Dindo classification. Hasson technique was used for peritoneal entry, GelPOINT advanced access platform was inserted, and standard 5mm laparoscopic instruments were used. Fifty-nine patients (median age 5 years, 4 months-17 years) met inclusion criteria: 29 nephrectomies, 9 nephroureterectomies, 3 bilateral nephrectomies, 5 heminephrectomies, 5 renal cyst decortications, 3 bilateral gonadectomies, 2 Malone antegrade continence enema, 2 calyceal diverticulectomy, and 1 ovarian detorsion with cystectomy. Median operative times for each case type were comparable to published experiences with traditional laparoscopy. Overall mean and median length of stay was 36.2 hours and 1 day, respectively. There were two complications: port site hernia requiring surgical repair (Clavien IIIb) and a superficial port site infection that resolved with antibiotics (Clavien II). Cosmetic outcomes were subjectively well received by patients and their parents. Operative time was significantly shorter between the first half of the experience and the second half (102 vs 70 minutes, P  <  .05). LESS approach can be broadly applied across many major extirpative and reconstructive procedures within pediatric urology. Our series advances our field's utilization of this technique and its safety. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. MicroGen: a MIAME compliant web system for microarray experiment information and workflow management.

    PubMed

    Burgarella, Sarah; Cattaneo, Dario; Pinciroli, Francesco; Masseroli, Marco

    2005-12-01

    Improvements of bio-nano-technologies and biomolecular techniques have led to increasing production of high-throughput experimental data. Spotted cDNA microarray is one of the most diffuse technologies, used in single research laboratories and in biotechnology service facilities. Although they are routinely performed, spotted microarray experiments are complex procedures entailing several experimental steps and actors with different technical skills and roles. During an experiment, involved actors, who can also be located in a distance, need to access and share specific experiment information according to their roles. Furthermore, complete information describing all experimental steps must be orderly collected to allow subsequent correct interpretation of experimental results. We developed MicroGen, a web system for managing information and workflow in the production pipeline of spotted microarray experiments. It is constituted of a core multi-database system able to store all data completely characterizing different spotted microarray experiments according to the Minimum Information About Microarray Experiments (MIAME) standard, and of an intuitive and user-friendly web interface able to support the collaborative work required among multidisciplinary actors and roles involved in spotted microarray experiment production. MicroGen supports six types of user roles: the researcher who designs and requests the experiment, the spotting operator, the hybridisation operator, the image processing operator, the system administrator, and the generic public user who can access the unrestricted part of the system to get information about MicroGen services. MicroGen represents a MIAME compliant information system that enables managing workflow and supporting collaborative work in spotted microarray experiment production.

  13. Pilot Domain Task Experience in Night Fatal Helicopter Emergency Medical Service Accidents.

    PubMed

    Aherne, Bryan B; Zhang, Chrystal; Newman, David G

    2016-06-01

    In the United States, accident and fatality rates in helicopter emergency medical service (HEMS) operations increase significantly under nighttime environmentally hazardous operational conditions. Other studies have found pilots' total flight hours unrelated to HEMS accident outcomes. Many factors affect pilots' decision making, including their experience. This study seeks to investigate whether pilot domain task experience (DTE) in HEMS plays a role against likelihood of accidents at night when hazardous operational conditions are entered. There were 32 flights with single pilot nighttime fatal HEMS accidents between 1995 and 2013 with findings of controlled flight into terrain (CFIT) and loss of control (LCTRL) due to spatial disorientation (SD) identified. The HEMS DTE of the pilots were compared with industry survey data. Of the pilots, 56% had ≤2 yr of HEMS experience and 9% had >10 yr of HEMS experience. There were 21 (66%) accidents that occurred in non-visual flight rules (VFR) conditions despite all flights being required to be conducted under VFR. There was a statistically significant increase in accident rates in pilots with <2 and <4 yr HEMS DTE and a statistically significant decrease in accident rates in pilots with >10 yr HEMS DTE. HEMS DTE plays a preventive role against the likelihood of a night operational accident. Pilots with limited HEMS DTE are more likely to make a poor assessment of hazardous conditions at night, and this will place HEMS flight crew at high risk in the VFR night domain.

  14. Low-cost, single-mode diode-pumped Cr:Colquiriite lasers.

    PubMed

    Demirbas, Umit; Li, Duo; Birge, Jonathan R; Sennaroglu, Alphan; Petrich, Gale S; Kolodziejski, Leslie A; Kaertner, Franz X; Fujimoto, James G

    2009-08-03

    We present three Cr3+:Colquiriite lasers as low-cost alternatives to Ti:Sapphire laser technology. Single-mode laser diodes, which cost only $150 each, were used as pump sources. In cw operation, with approximately 520 mW of absorbed pump power, up to 257, 269 and 266 mW of output power and slope efficiencies of 53%, 62% and 54% were demonstrated for Cr:LiSAF, Cr:LiSGaF and Cr:LiCAF, respectively. Record cw tuning ranges from 782 to 1042 nm for Cr:LiSAF, 777 to 977 nm for Cr:LiSGaF, and 754 to 871 nm for Cr:LiCAF were demonstrated. In cw mode-locking experiments using semiconductor saturable absorber mirrors at 800 and 850 nm, Cr:Colquiriite lasers produced approximately 50-100 fs pulses with approximately 1-2.5 nJ pulse energies at approximately 100 MHz repetition rate. Electrical-to-optical conversion efficiencies of 8% in mode-locked operation and 12% in cw operation were achieved.

  15. A Validated Task Analysis of the Single Pilot Operations Concept

    NASA Technical Reports Server (NTRS)

    Wolter, Cynthia A.; Gore, Brian F.

    2015-01-01

    The current day flight deck operational environment consists of a two-person Captain/First Officer crew. A concept of operations (ConOps) to reduce the commercial cockpit to a single pilot from the current two pilot crew is termed Single Pilot Operations (SPO). This concept has been under study by researchers in the Flight Deck Display Research Laboratory (FDDRL) at the National Aeronautics and Space Administration's (NASA) Ames (Johnson, Comerford, Lachter, Battiste, Feary, and Mogford, 2012) and researchers from Langley Research Centers (Schutte et al., 2007). Transitioning from a two pilot crew to a single pilot crew will undoubtedly require changes in operational procedures, crew coordination, use of automation, and in how the roles and responsibilities of the flight deck and ATC are conceptualized in order to maintain the high levels of safety expected of the US National Airspace System. These modifications will affect the roles and the subsequent tasks that are required of the various operators in the NextGen environment. The current report outlines the process taken to identify and document the tasks required by the crew according to a number of operational scenarios studied by the FDDRL between the years 2012-2014. A baseline task decomposition has been refined to represent the tasks consistent with a new set of entities, tasks, roles, and responsibilities being explored by the FDDRL as the move is made towards SPO. Information from Subject Matter Expert interviews, participation in FDDRL experimental design meetings, and study observation was used to populate and refine task sets that were developed as part of the SPO task analyses. The task analysis is based upon the proposed ConOps for the third FDDRL SPO study. This experiment possessed nine different entities operating in six scenarios using a variety of SPO-related automation and procedural activities required to guide safe and efficient aircraft operations. The task analysis presents the roles and responsibilities in a manner that can facilitate testing future scenarios. Measures of task count and workload were defined and analyzed to assess the impact of transitioning to a SPO environment.

  16. Analysis of the diffusion of Ras2 in Saccharomyces cerevisiae using fluorescence recovery after photobleaching

    NASA Astrophysics Data System (ADS)

    Vinnakota, Kalyan C.; Mitchell, David A.; Deschenes, Robert J.; Wakatsuki, Tetsuro; Beard, Daniel A.

    2010-06-01

    Binding, lateral diffusion and exchange are fundamental dynamic processes involved in protein association with cellular membranes. In this study, we developed numerical simulations of lateral diffusion and exchange of fluorophores in membranes with arbitrary bleach geometry and exchange of the membrane-localized fluorophore with the cytosol during fluorescence recovery after photobleaching (FRAP) experiments. The model simulations were used to design FRAP experiments with varying bleach region sizes on plasma membrane-localized wild-type GFP-Ras2 with a dual lipid anchor and mutant GFP-Ras2C318S with a single lipid anchor in live yeast cells to investigate diffusional mobility and the presence of any exchange processes operating in the time scale of our experiments. Model parameters estimated using data from FRAP experiments with a 1 µm × 1 µm bleach region-of-interest (ROI) and a 0.5 µm × 0.5 µm bleach ROI showed that GFP-Ras2, single or dual lipid modified, diffuses as single species with no evidence of exchange with a cytoplasmic pool. This is the first report of Ras2 mobility in the yeast plasma membrane. The methods developed in this study are generally applicable for studying diffusion and exchange of membrane-associated fluorophores using FRAP on commercial confocal laser scanning microscopes.

  17. Culture and Character Education in a Jewish Day School: A Case Study of Life and Experience

    ERIC Educational Resources Information Center

    Roso, Calvin G.

    2013-01-01

    This article addresses how to teach character comprehensively by studying ways a school's concurrent curricula (the official curriculum, the operational curriculum, the extra curriculum, and the hidden curriculum) can be used to teach character to students. A single case study analyzes the curriculum at a Jewish day school by examining school…

  18. Characterization of a nine-meter sensor-equipped wind turbine blade using a laser measuring device

    USDA-ARS?s Scientific Manuscript database

    A nine-meter turbine blade was prepared for an experiment to examine the movement and fatigue patterns during operation on a 115 kW turbine. The blade, equipped with surface mounted fiber optic strain gauges, foil strain gauges, single, and triple axis accelerometers was placed on a calibration fixt...

  19. Continuous separation of copper ions from a mixture of heavy metal ions using a three-zone carousel process packed with metal ion-imprinted polymer.

    PubMed

    Jo, Se-Hee; Lee, See-Young; Park, Kyeong-Mok; Yi, Sung Chul; Kim, Dukjoon; Mun, Sungyong

    2010-11-05

    In this study, a three-zone carousel process based on a proper molecular imprinted polymer (MIP) resin was developed for continuous separation of Cu(2+) from Mn(2+) and Co(2+). For this task, the Cu (II)-imprinted polymer (Cu-MIP) resin was synthesized first and used to pack the chromatographic columns of a three-zone carousel process. Prior to the experiment of the carousel process based on the Cu-MIP resin (MIP-carousel process), a series of single-column experiments were performed to estimate the intrinsic parameters of the three heavy metal ions and to find out the appropriate conditions of regeneration and re-equilibration. The results from these single-column experiments and the additional computer simulations were then used for determination of the operating parameters of the MIP-carousel process under consideration. Based on the determined operating parameters, the MIP-carousel experiments were carried out. It was confirmed from the experimental results that the proposed MIP-carousel process was markedly effective in separating Cu(2+) from Mn(2+) and Co(2+) in a continuous mode with high purity and a relatively small loss. Thus, the MIP-carousel process developed in this study deserves sufficient attention in materials processing industries or metal-related industries, where the selective separation of heavy metal ions with the same charge has been a major concern. Copyright © 2010 Elsevier B.V. All rights reserved.

  20. GEWEX - The Global Energy and Water Cycle Experiment

    NASA Technical Reports Server (NTRS)

    Chahine, Moustafa T.

    1992-01-01

    GEWEX, which is part of the World Climate Research Program, has as its goal an order-of-magnitude improvement in the ability to model global precipitation and evaporation and furnish an accurate assessment of the sensitivity of atmospheric radiation and clouds. Attention will also be given to the response of the hydrological cycle and water resources to climate change. GEWEX employs a single program to coordinate all aspects of climatology from model development to the deployment and operation of observational systems. GEWEX will operate over the next two decades.

  1. Numerical solution of the stochastic parabolic equation with the dependent operator coefficient

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ashyralyev, Allaberen; Department of Mathematics, ITTU, Ashgabat; Okur, Ulker

    2015-09-18

    In the present paper, a single step implicit difference scheme for the numerical solution of the stochastic parabolic equation with the dependent operator coefficient is presented. Theorem on convergence estimates for the solution of this difference scheme is established. In applications, this abstract result permits us to obtain the convergence estimates for the solution of difference schemes for the numerical solution of initial boundary value problems for parabolic equations. The theoretical statements for the solution of this difference scheme are supported by the results of numerical experiments.

  2. A sorting system with automated gates permits individual operant experiments with mice from a social home cage.

    PubMed

    Winter, York; Schaefers, Andrea T U

    2011-03-30

    Behavioral experiments based on operant procedures can be time-consuming for small amounts of data. While individual testing and handling of animals can influence attention, emotion, and behavior, and interfere with experimental outcome, many operant protocols require individual testing. We developed an RFID-technology- and transponder-based sorting system that allows removing the human factor for longer-term experiments. Identity detectors and automated gates route mice individually from their social home cage to an adjacent operant compartment with 24/7 operation. CD1-mice learnt quickly to individually pass through the sorting system. At no time did more than a single mouse enter the operant compartment. After 3 days of adjusting to the sorting system, groups of 4 mice completed about 50 experimental trials per day in the operant compartment without experimenter intervention. The automated sorting system eliminates handling, isolation, and disturbance of the animals, eliminates experimenter-induced variability, saves experimenter time, and is financially economical. It makes possible a new approach for high-throughput experimentation, and is a viable tool for increasing quality and efficiency of many behavioral and neurobiological investigations. It can connect a social home cage, through individual sorting automation, to diverse setups including classical operant chambers, mazes, or arenas with video-based behavior classification. Such highly automated systems will permit efficient high-throughput screening even for transgenic animals with only subtle neurological or psychiatric symptoms where elaborate or longer-term protocols are required for behavioral diagnosis. Copyright © 2011 Elsevier B.V. All rights reserved.

  3. Single photon detection and timing in the Lunar Laser Ranging Experiment.

    NASA Technical Reports Server (NTRS)

    Poultney, S. K.

    1972-01-01

    The goals of the Lunar Laser Ranging Experiment lead to the need for the measurement of a 2.5 sec time interval to an accuracy of a nanosecond or better. The systems analysis which included practical retroreflector arrays, available laser systems, and large telescopes led to the necessity of single photon detection. Operation under all background illumination conditions required auxiliary range gates and extremely narrow spectral and spatial filters in addition to the effective gate provided by the time resolution. Nanosecond timing precision at relatively high detection efficiency was obtained using the RCA C31000F photomultiplier and Ortec 270 constant fraction of pulse-height timing discriminator. The timing accuracy over the 2.5 sec interval was obtained using a digital interval with analog vernier ends. Both precision and accuracy are currently checked internally using a triggerable, nanosecond light pulser. Future measurements using sub-nanosecond laser pulses will be limited by the time resolution of single photon detectors.

  4. Safety and efficacy of percutaneous nephrolithotomy for the treatment of paediatric urolithiasis

    PubMed Central

    Veeratterapillay, R; Shaw, MBK; Williams, R; Haslam, P; Lall, A; De la Hunt, M; Hasan, ST; Thomas, DJ

    2012-01-01

    INTRODUCTION Paediatric percutaneous nephrolithotomy (PCNL) has revolutionised the treatment of paediatric nephrolithiasis. Paediatric PCNL has been performed using both adult and paediatric instruments. Stone clearance rates and complications vary according to the technique used and surgeon experience. We present our experience with PCNL using adult instruments and a 28Fr access tract for large renal calculi in children under 18 years. METHODS All patients undergoing PCNL at our institution between 2000 and 2009 were reviewed. Demographics, surgical details and post-operative follow-up information were obtained to identify stone clearance rates and complications. RESULTS PCNL was performed in 32 renal units in 31 patients (mean age: 10.8 years). The mean stone diameter was 19mm (range: 5–40mm). Twenty-six cases required single puncture and six required multiple tracts. Overall, 11 staghorn stones, 10 multiple calyceal stones and 11 single stones were treated. Twenty-seven patients (84%) were completely stone free following initial PCNL. Two cases had extracorporeal shock wave lithotripsy for residual fragments, giving an overall stone free rate of 91% following treatment. There was no significant bleeding or sepsis encountered either during the operation or in the post-operative setting. No patient required or received a blood transfusion. CONCLUSIONS Paediatric PCNL can be performed safely with minimal morbidity using adult instruments for large stone burden, enabling rapid and complete stone clearance. PMID:23131231

  5. Safety and efficacy of percutaneous nephrolithotomy for the treatment of paediatric urolithiasis.

    PubMed

    Veeratterapillay, R; Shaw, M B K; Williams, R; Haslam, P; Lall, A; De la Hunt, M; Hasan, S T; Thomas, D J

    2012-11-01

    Paediatric percutaneous nephrolithotomy (PCNL) has revolutionised the treatment of paediatric nephrolithiasis. Paediatric PCNL has been performed using both adult and paediatric instruments. Stone clearance rates and complications vary according to the technique used and surgeon experience. We present our experience with PCNL using adult instruments and a 28Fr access tract for large renal calculi in children under 18 years. All patients undergoing PCNL at our institution between 2000 and 2009 were reviewed. Demographics, surgical details and post-operative follow-up information were obtained to identify stone clearance rates and complications. PCNL was performed in 32 renal units in 31 patients (mean age: 10.8 years). The mean stone diameter was 19mm (range: 5-40mm). Twenty-six cases required single puncture and six required multiple tracts. Overall, 11 staghorn stones, 10 multiple calyceal stones and 11 single stones were treated. Twenty-seven patients (84%) were completely stone free following initial PCNL. Two cases had extracorporeal shock wave lithotripsy for residual fragments, giving an overall stone free rate of 91% following treatment. There was no significant bleeding or sepsis encountered either during the operation or in the post-operative setting. No patient required or received a blood transfusion. Paediatric PCNL can be performed safely with minimal morbidity using adult instruments for large stone burden, enabling rapid and complete stone clearance.

  6. Laparoendoscopic single site (LESS) cholecystectomy.

    PubMed

    Hodgett, Steven E; Hernandez, Jonathan M; Morton, Connor A; Ross, Sharona B; Albrink, Michael; Rosemurgy, Alexander S

    2009-02-01

    The journey from conventional "open" operations to truly "minimally invasive" operations naturally includes progression from operations involving multiple trocars and multiple incisions to operations involving access through the umbilicus alone. Laparoscopic operations through the umbilicus alone, laparoendoscopic single site surgery (LESS), offer improved cosmesis and hopes for less pain and improved recovery. This study was undertaken to evaluate our initial experience with LESS cholecystectomy and to compare our initial experience to concurrent outcomes with more conventional multiport, multi-incision laparoscopic cholecystectomy. All patients referred for cholecystectomy over a 6-month period were offered LESS. Outcomes, including blood loss, operative time, complications, and length of stay were recorded. Outcomes with our first LESS cholecystectomies were compared to an uncontrolled group of concurrent patients undergoing multiport, multi-incision laparoscopic cholecystectomy at the same hospital by the same surgeon. Twenty-nine patients of median age 50 years undergoing LESS cholecystectomy from November 2007 until May 2008 were compared to 29* patients, median age 48 years, undergoing standard multiport, multiple-incision laparoscopic cholecystectomy over the same time period. Median operative time for patients undergoing LESS cholecystectomy was 72 min and was not different from that of patients undergoing multiport, multi-incision laparoscopic cholecystectomy (p = 0.81). Median length of hospital stay was 1.0 day for patients undergoing LESS cholecystectomy and was not different from patients undergoing standard laparoscopic cholecystectomy (p = 0.46). Operative estimated blood loss was less than 100 cc for all patients. No patients undergoing attempted LESS cholecystectomy had conversions to "open" operations; two patients had an additional trocar(s) placed distant from the umbilicus to aid in exposure. Three patients undergoing LESS cholecystectomy had complications: two were troubled by pain control and another had urinary retention. LESS cholecystectomy is a safe and effective alternative to standard laparoscopic cholecystectomy. It can be undertaken without the expense of added operative time and provides patients with minimal, if any, apparent scarring. We believe LESS cholecystectomy will be driven by consumer demand, and therefore, laparoscopic surgeons will need to become proficient with LESS procedures.

  7. Incidence of post-operative pain after single visit and multiple visit root canal treatment: A randomized controlled trial

    PubMed Central

    Singh, Smita; Garg, Aniket

    2012-01-01

    Aim: To compare the incidence and intensity of post-obturation pain after single or multi visit root canal treatment on single rooted teeth in a randomized controlled trial. Materials and Methods: Two hundred patients requiring root canal treatment on permanent single rooted teeth (both vital and non vital) were included. The patients were assigned randomly into two groups of 100 patients each. The teeth in Group1 (n = 100) were obturated at the first visit, whilst those in Group 2 (n = 100) were obturated in a second visit 7 days later. A modified Heft Parker visual analog scale was used to measure pre-operative pain and post-obturation pain at 6, 12, 24 and 48 hours after obturation. Independent-sample T-tests was used for statistical analysis. Results: Twelve patients were excluded from the study as they failed to follow the scheduled revisit. Data were obtained from the remaining 188 patients. There was no statistically significant difference in the incidence and intensity of post-obturation pain experienced by two groups. Conclusions: The incidence and intensity of post-obturation pain experience following one- or two-visit root canal treatment on teeth with a single canal were not significantly different. PMID:23112477

  8. Multi-unit Operations in Non-Nuclear Systems: Lessons Learned for Small Modular Reactors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    OHara J. M.; Higgins, J.; DAgostino, A.

    2012-01-17

    The nuclear-power community has reached the stage of proposing advanced reactor designs to support power generation for decades to come. Small modular reactors (SMRs) are one approach to meet these energy needs. While the power output of individual reactor modules is relatively small, they can be grouped to produce reactor sites with different outputs. Also, they can be designed to generate hydrogen, or to process heat. Many characteristics of SMRs are quite different from those of current plants and may be operated quite differently. One difference is that multiple units may be operated by a single crew (or a singlemore » operator) from one control room. The U.S. Nuclear Regulatory Commission (NRC) is examining the human factors engineering (HFE) aspects of SMRs to support licensing reviews. While we reviewed information on SMR designs to obtain information, the designs are not completed and all of the design and operational information is not yet available. Nor is there information on multi-unit operations as envisioned for SMRs available in operating experience. Thus, to gain a better understanding of multi-unit operations we sought the lesson learned from non-nuclear systems that have experience in multi-unit operations, specifically refineries, unmanned aerial vehicles and tele-intensive care units. In this paper we report the lessons learned from these systems and the implications for SMRs.« less

  9. Semi-rigid single hook localization the best method for localizing ground glass opacities during video-assisted thoracoscopic surgery: re-aerated swine lung experimental and primary clinical results

    PubMed Central

    Zhao, Guang; Sun, Long; Geng, Guojun; Liu, Hongming; Li, Ning; Liu, Suhuan; Hao, Bing

    2017-01-01

    Background The aim of this study was to compare the effects of currently available preoperative localization methods, including semi-rigid single hook-wire, double-thorn hook-wire, and microcoil, in localizing the pulmonary nodules, thus to select the best technology to assist video-assisted thoracoscopic surgery (VATS) for small ground glass opacities (GGO). Methods Preoperative CT-guided localizing techniques including semi-rigid single hook-wire, double-thorn hook-wire and microcoil were used in re-aerated fresh swine lung for location experiments. The advantages and drawbacks of the three positioning technologies were compared, and then the most optimal technique was used in patients with GGO. Technical success and post-operative complications were used as primary endpoints. Results All three localizing techniques were successfully performed in the re-aerated fresh swine lung. The median tractive force of semi-rigid single hook wire, double-thorn hook wire and microcoil were 6.5, 4.85 and 0.2 N, which measured by a spring dynamometer. The wound sizes in the superficial pleura, caused by unplugging the needles, were 2 mm in double-thorn hook wire, 1 mm in semi-rigid single hook and 1 mm in microcoil, respectively. In patients with GGOs, the semi-rigid hook wires localizations were successfully performed, without any complication that need to be intervened. Dislodgement was reported in one patient before VATS. No major complications related to the preoperative hook wire localization and VATS were observed. Conclusions We found from our localization experiments in the swine lung that, among the commonly used three localization methods, semi-rigid hook wire showed the best operability and practicability than double-thorn hook wire and microcoil. Preoperative localization of small pulmonary nodules with single semi-rigid hook wire system shows a high success rate, acceptable utility and especially low dislodgement in VATS. PMID:29312722

  10. Effect of Surface Preparation on the 815°C Oxidation of Single-Crystal Nickel-Based Superalloys

    NASA Astrophysics Data System (ADS)

    Sudbrack, Chantal K.; Beckett, Devon L.; MacKay, Rebecca A.

    2015-11-01

    A primary application for single-crystal superalloys has been jet engine turbine blades, where operation temperatures reach well above 1000°C. The NASA Glenn Research Center is considering use of single-crystal alloys for future, lower temperature application in the rims of jet engine turbine disks. Mechanical and environmental properties required for potential disk rim operation at 815°C are being examined, including the oxidation and corrosion behavior, where there is little documentation at intermediate temperatures. In this study, single-crystal superalloys, LDS-1101+Hf and CMSX-4+Y, were prepared with different surface finishes and compared after isothermal and cyclic oxidation exposures. Surface finish has a clear effect on oxide formation at 815°C. Machined low-stress ground surfaces after exposure for 440 h produce thin Al2O3 external scales, which is consistent with higher temperature oxidation, whereas polished surfaces with a mirror finish yield much thicker NiO external scales with subscale of Cr2O3-spinel-Al2O3, which may offer less reliable oxidation resistance. Additional experiments separate the roles of cold-work, localized deformation, and the extent of polishing and surface roughness on oxide formation.

  11. The Functional Measurement Experiment Builder suite: two Java-based programs to generate and run functional measurement experiments.

    PubMed

    Mairesse, Olivier; Hofmans, Joeri; Theuns, Peter

    2008-05-01

    We propose a free, easy-to-use computer program that does not requires prior knowledge of computer programming to generate and run experiments using textual or pictorial stimuli. Although the FM Experiment Builder suite was initially programmed for building and conducting FM experiments, it can also be applied for non-FM experiments that necessitate randomized, single, or multifactorial designs. The program is highly configurable, allowing multilingual use and a wide range of different response formats. The outputs of the experiments are Microsoft Excel compatible .xls files that allow easy copy-paste of the results into Weiss's FM CalSTAT program (2006) or any other statistical package. Its Java-based structure is compatible with both Windows and Macintosh operating systems, and its compactness (< 1 MB) makes it easily distributable over the Internet.

  12. A Novel Scheme for Bidirectional and Hybrid Quantum Information Transmission via a Seven-Qubit State

    NASA Astrophysics Data System (ADS)

    Fang, Sheng-hui; Jiang, Min

    2018-02-01

    In this paper, we present a novel scheme for bidirectional and hybrid quantum information transmission via a seven-qubit state. We demonstrate that under the control of the supervisor two distant participants can simultaneously and deterministically exchange their states with each other no matter whether they know the states or not. In our scheme, Alice can teleport an arbitrary single-qubit state (two-qubit state) to Bob and Bob can prepare a known two-qubit state (single-qubit state) for Alice simultaneously via the control of the supervisor Charlie. Compared with previous studies for single bidirectional quantum teleportation or single bidirectional remote state preparation schemes, our protocol is a kind of hybrid approach for quantum information transmission. Furthermore, it achieves success with unit probability. Notably, since only pauli operations and two-qubit and single-qubit measurements are used in our schemes, it is flexible in physical experiments.

  13. The Ross Procedure in Pediatric Patients: A 20-Year Experience of Ross Procedure in a Single Institution

    PubMed Central

    Yoon, Dong Woog; Yang, Ji-Hyuk; Jun, Tae-Gook; Park, Pyo Won

    2017-01-01

    Background The Ross/Ross-Konno procedure is considered a good option for irreparable aortic valve disease in pediatric patients because of its hemodynamic performance and potential for growth of the pulmonary autograft. This study is a review of the long-term results of our 20-year experience with the Ross and Ross-Konno operations in a single institution. Methods Between June 1995 and January 2016, 16 consecutive patients (mean age, 6.0±5.9 years; range, 16 days to 17.4 years) underwent either a Ross operation (n=9) or a Ross-Konno operation (n=7). The study included 12 males and 4 females, with a median follow-up period of 47 months (range, 6 to 256 months). Results There were no cases of in-hospital or late mortality. Six reoperations were performed in 5 patients. Four patients underwent right ventricular-pulmonary artery (RV-PA) conduit replacement. Two patients underwent concomitant replacement of the pulmonary autograft and RV-PA conduit 10 years and 8 years after the Ross operation, respectively. The rate of freedom from adverse outcomes of the pulmonary autograft was 88% and 70% at 5 and 10 years, respectively. The rate of freedom from valve-related reoperations was 79% and 63% at 5 and 10 years, respectively. Conclusion Pulmonary autografts demonstrated good durability with low mortality. The Ross/Ross-Konno procedure is a good option that can be performed safely in pediatric patients with aortic valve disease, even in a small-volume center. PMID:28795027

  14. First 101 Robotic General Surgery Cases in a Community Hospital

    PubMed Central

    Robertson, Jarrod C.; Alrajhi, Sharifah

    2016-01-01

    Background and Objectives: The general surgeon's robotic learning curve may improve if the experience is classified into categories based on the complexity of the procedures in a small community hospital. The intraoperative time should decrease and the incidence of complications should be comparable to conventional laparoscopy. The learning curve of a single robotic general surgeon in a small community hospital using the da Vinci S platform was analyzed. Methods: Measured parameters were operative time, console time, conversion rates, complications, surgical site infections (SSIs), surgical site occurrences (SSOs), length of stay, and patient demographics. Results: Between March 2014 and August 2015, 101 robotic general surgery cases were performed by a single surgeon in a 266-bed community hospital, including laparoscopic cholecystectomies, inguinal hernia repairs; ventral, incisional, and umbilical hernia repairs; and colorectal, foregut, bariatric, and miscellaneous procedures. Ninety-nine of the cases were completed robotically. Seven patients were readmitted within 30 days. There were 8 complications (7.92%). There were no mortalities and all complications were resolved with good outcomes. The mean operative time was 233.0 minutes. The mean console operative time was 117.6 minutes. Conclusion: A robotic general surgery program can be safely implemented in a small community hospital with extensive training of the surgical team through basic robotic skills courses as well as supplemental educational experiences. Although the use of the robotic platform in general surgery could be limited to complex procedures such as foregut and colorectal surgery, it can also be safely used in a large variety of operations with results similar to those of conventional laparoscopy. PMID:27667913

  15. First 101 Robotic General Surgery Cases in a Community Hospital.

    PubMed

    Oviedo, Rodolfo J; Robertson, Jarrod C; Alrajhi, Sharifah

    2016-01-01

    The general surgeon's robotic learning curve may improve if the experience is classified into categories based on the complexity of the procedures in a small community hospital. The intraoperative time should decrease and the incidence of complications should be comparable to conventional laparoscopy. The learning curve of a single robotic general surgeon in a small community hospital using the da Vinci S platform was analyzed. Measured parameters were operative time, console time, conversion rates, complications, surgical site infections (SSIs), surgical site occurrences (SSOs), length of stay, and patient demographics. Between March 2014 and August 2015, 101 robotic general surgery cases were performed by a single surgeon in a 266-bed community hospital, including laparoscopic cholecystectomies, inguinal hernia repairs; ventral, incisional, and umbilical hernia repairs; and colorectal, foregut, bariatric, and miscellaneous procedures. Ninety-nine of the cases were completed robotically. Seven patients were readmitted within 30 days. There were 8 complications (7.92%). There were no mortalities and all complications were resolved with good outcomes. The mean operative time was 233.0 minutes. The mean console operative time was 117.6 minutes. A robotic general surgery program can be safely implemented in a small community hospital with extensive training of the surgical team through basic robotic skills courses as well as supplemental educational experiences. Although the use of the robotic platform in general surgery could be limited to complex procedures such as foregut and colorectal surgery, it can also be safely used in a large variety of operations with results similar to those of conventional laparoscopy.

  16. Sustainable Hypersaline Microbial Fuel Cells: Inexpensive Recyclable Polymer Supports for Carbon Nanotube Conductive Paint Anodes.

    PubMed

    Grattieri, Matteo; Shivel, Nelson D; Sifat, Iram; Bestetti, Massimiliano; Minteer, Shelley D

    2017-05-09

    Microbial fuel cells are an emerging technology for wastewater treatment, but to be commercially viable and sustainable, the electrode materials must be inexpensive, recyclable, and reliable. In this study, recyclable polymeric supports were explored for the development of anode electrodes to be applied in single-chamber microbial fuel cells operated in field under hypersaline conditions. The support was covered with a carbon nanotube (CNT) based conductive paint, and biofilms were able to colonize the electrodes. The single-chamber microbial fuel cells with Pt-free cathodes delivered a reproducible power output after 15 days of operation to achieve 12±1 mW m -2 at a current density of 69±7 mA m -2 . The decrease of the performance in long-term experiments was mostly related to inorganic precipitates on the cathode electrode and did not affect the performance of the anode, as shown by experiments in which the cathode was replaced and the fuel cell performance was regenerated. The results of these studies show the feasibility of polymeric supports coated with CNT-based paint for microbial fuel cell applications. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. CFD modeling and experimental verification of a single-stage coaxial Stirling-type pulse tube cryocooler without either double-inlet or multi-bypass operating at 30-35 K using mixed stainless steel mesh regenerator matrices

    NASA Astrophysics Data System (ADS)

    Dang, Haizheng; Zhao, Yibo

    2016-09-01

    This paper presents the CFD modeling and experimental verifications of a single-stage inertance tube coaxial Stirling-type pulse tube cryocooler operating at 30-35 K using mixed stainless steel mesh regenerator matrices without either double-inlet or multi-bypass. A two-dimensional axis-symmetric CFD model with the thermal non-equilibrium mode is developed to simulate the internal process, and the underlying mechanism of significantly reducing the regenerator losses with mixed matrices is discussed in detail based on the given six cases. The modeling also indicates that the combination of the given different mesh segments can be optimized to achieve the highest cooling efficiency or the largest exergy ratio, and then the verification experiments are conducted in which the satisfactory agreements between simulated and tested results are observed. The experiments achieve a no-load temperature of 27.2 K and the cooling power of 0.78 W at 35 K, or 0.29 W at 30 K, with an input electric power of 220 W and a reject temperature of 300 K.

  18. Routine transradial access for conventional cerebral angiography: a single operator's experience of its feasibility and safety.

    PubMed

    Lee, D H; Ahn, J H; Jeong, S S; Eo, K S; Park, M S

    2004-10-01

    The purpose of this study is to describe a single operator's experience with the feasibility and safety of transradial access in conventional cerebral angiography. 153 patients were enrolled consecutively. Among them, 20 patients were not suitable for transradial access. A Simmons catheter was used. Haemostasis was achieved using a compressive dressing of the wrist. We analysed the success rates of the arterial puncture and the successful catheterization rate for each supra-aortic vessel as well as all complications. The arterial access was successful in 96.3%. The supra-aortic vessels were catheterized with success rates of 99.2% (127/128) for the left subclavian artery and 100% for the other arteries. The mean procedure time was 19.3 min (range 10-55 min). Haemostasis was successfully achieved in every case. The most frequent complication was arm pain which occurred in 37 patients (28.9%). In conclusion, transradial selective cerebral angiography with a reversed-angle catheter is technically feasible and safe. It might be helpful in imaging follow-up of patients with arterial stenting or coil embolisation of the cerebral aneurysms. Modification of the catheter design is required to improve the selectivity of the supra-aortic branches.

  19. AMO EXPRESS: A Command and Control Experiment for Crew Autonomy Onboard the International Space Station

    NASA Technical Reports Server (NTRS)

    Stetson, Howard K.; Haddock, Angie T.; Frank, Jeremy; Cornelius, Randy; Wang, Lui; Garner, Larry

    2015-01-01

    NASA is investigating a range of future human spaceflight missions, including both Mars-distance and Near Earth Object (NEO) targets. Of significant importance for these missions is the balance between crew autonomy and vehicle automation. As distance from Earth results in increasing communication delays, future crews need both the capability and authority to independently make decisions. However, small crews cannot take on all functions performed by ground today, and so vehicles must be more automated to reduce the crew workload for such missions. NASA's Advanced Exploration Systems Program funded Autonomous Mission Operations (AMO) project conducted an autonomous command and control experiment on-board the International Space Station that demonstrated single action intelligent procedures for crew command and control. The target problem was to enable crew initialization of a facility class rack with power and thermal interfaces, and involving core and payload command and telemetry processing, without support from ground controllers. This autonomous operations capability is enabling in scenarios such as initialization of a medical facility to respond to a crew medical emergency, and representative of other spacecraft autonomy challenges. The experiment was conducted using the Expedite the Processing of Experiments for Space Station (EXPRESS) rack 7, which was located in the Port 2 location within the U.S Laboratory onboard the International Space Station (ISS). Activation and deactivation of this facility is time consuming and operationally intensive, requiring coordination of three flight control positions, 47 nominal steps, 57 commands, 276 telemetry checks, and coordination of multiple ISS systems (both core and payload). Utilization of Draper Laboratory's Timeliner software, deployed on-board the ISS within the Command and Control (C&C) computers and the Payload computers, allowed development of the automated procedures specific to ISS without having to certify and employ novel software for procedure development and execution. The procedures contained the ground procedure logic and actions as possible to include fault detection and recovery capabilities. The autonomous operations concept includes a reduction of the amount of data a crew operator is required to verify during activation or de-activation, as well as integration of procedure execution status and relevant data in a single integrated display. During execution, the auto-procedures (via Timerliner) provide a step-by-step messaging paradigm and a high-level status upon termination. This messaging and high-level status is the only data generated for operator display. To enhance situational awareness of the operator, the Web-based Procedure Display (WebPD) provides a novel approach to the issues of procedure display and execution tracking. WebPD is a web based application that serves as the user interface for electronic procedure execution. It incorporates several aspects of the HTML5 standard. Procedures are written in a dialect of XML called Procedure Representation Language (PRL). WebPD tracks execution status in the procedure or procedures being displayed. WebPD aggregates and simplifies the auto-sequence execution status information, and formatted to be easily followed and understood by an operator who is not dedicated to actively monitoring the task. WebPD also provides an integrated data and control interface to pause or halt the execution in order to provide a check point of operation and to examine progress before starting the next sequence of activities. For this demonstration, the procedure was initiated and monitored from the ground. As the Timeliner sequences executed, their high-level execution status was written to PLMDM memory. This memory is read and downlinked via Ku-Band at a 1 Hz rate. The data containing the high-level execution status is de-commutated on the ground, and rebroadcast for WebPD consumption. A future demonstration will be performed onboard, with ISS astronauts initiating the operations instead of ground controllers. The AMO EXPRESS experiment demonstrated activation and de-activation of EXPRESS rack 7, providing the capability of future single button activations and deactivations of facility class racks. The experiment achieved numerous technical and operations 'firsts' for the ISS

  20. Fetoscopic single-layer repair of open spina bifida using a cellulose patch: preliminary clinical experience.

    PubMed

    Pedreira, Denise A L; Zanon, Nelci; de Sá, Renato A M; Acacio, Gregório L; Ogeda, Edilson; Belem, Teresa M L O U; Chmait, Ramen H; Kontopoulos, Eftichia; Quintero, Ruben A

    2014-11-01

    To report our preliminary clinical experience in the antenatal correction of open spina bifida (OSB) using a fetoscopic approach and a simplified closure technique. Four fetuses with lumbar-sacral defects were operated in utero from 25 to 27 weeks. Surgeries were performed percutaneously under general anesthesia using three trocars and partial carbon dioxide insufflation. After dissection of the neural placode, the surrounding skin was closed over a cellulose patch using a single continuous stitch. Surgical closure was successful in three of the four cases. All successful cases showed improvement of the hindbrain herniation and no neonatal neurosurgical repair was required in two cases. Delivery occurred between 31 and 33 weeks, and no fetal or neonatal deaths occurred. Ventriculoperitoneal shunting was not needed in two out of the 3 successful cases. Our preliminary experience suggests that definitive fetoscopic repair of OSB is feasible using our innovative surgical technique. A phase I trial for the fetoscopic correction of OSB with this technique is currently being conducted.

  1. Systematic off-pump coronary artery revascularization in multivessel disease: experience of three hundred cases.

    PubMed

    Cartier, R; Brann, S; Dagenais, F; Martineau, R; Couturier, A

    2000-02-01

    We sought to report our recent experience with off-pump coronary artery revascularization in multivessel disease. Between October 1996 and December 1998, 300 off-pump beating heart operations were performed at the Montreal Heart Institute by a single surgeon, representing 94% of all procedures undertaken during this same time frame (97% for 1998). This cohort of patients was compared with 1870 patients operated on with cardiopulmonary bypass from 1995 to 1996. Mean age, sex distribution, and preoperative risk factors were comparable for the two groups. On average, 2.92 +/- 0.8 and 2.84 +/- 0.6 grafts per patient were completed in the beating heart and cardiopulmonary bypass groups, respectively. A majority of patients (70%) had either a triple or quadruple bypass. Coronary anastomoses were achieved with myocardial mechanical stabilization and heart "verticalization." Ischemic time was shorter in the beating heart group (29.8 +/- 0.9 vs 45 +/- 0.4 minutes, P <.05). Similarly, the need for transfusion was significantly less in the beating heart group (beating heart operations, 34%; cardiopulmonary bypass, 66%; P <.005). Reduced use of postoperative intra-aortic counterpulsation, as well as a lower rise in creatine kinase MB isoenzyme, was observed in the beating heart group. Operative mortality rates (beating heart operations, 1. 3%; cardiopulmonary bypass, 2%) and perioperative myocardial infarction (beating heart operations, 3.6%; cardiopulmonary bypass, 4.2%) were comparable for the two groups. In a majority of patients, off-pump complete coronary artery revascularization is an acceptable alternative to conventional operations, yielding good results given progressive experience, rigorous technique, and adequate coronary artery stabilization.

  2. Development of an Organic Rankine-Cycle power module for a small community solar thermal power experiment

    NASA Technical Reports Server (NTRS)

    Kiceniuk, T.

    1985-01-01

    An organic Rankine-cycle (ORC) power module was developed for use in a multimodule solar power plant to be built and operated in a small community. Many successful components and subsystems, including the reciever, power conversion subsystem, energy transport subsystem, and control subsystem, were tested. Tests were performed on a complete power module using a test bed concentrator in place of the proposed concentrator. All major single-module program functional objectives were met and the multimodule operation presented no apparent problems. The hermetically sealed, self-contained, ORC power conversion unit subsequently successfully completed a 300-hour endurance run with no evidence of wear or operating problems.

  3. Michael Additions of Highly Basic Enolates to ortho-Quinone Methides

    PubMed Central

    Lewis, Robert S.; Garza, Christopher J.; Dang, Ann T.; Pedro, Te Kie A.; Chain, William J.

    2015-01-01

    A protocol by which ketone or ester enolates and ortho-quinone methides (o-QMs) are generated in situ in a single reaction flask from silylated precursors under the action of anhydrous fluoride is reported. The reaction partners are joined to give a variety of β-(2-hydroxyphenyl)-carbonyl compounds in 32–94% yield in a single laboratory operation. The intermediacy of o-QMs is supported by control experiments utilizing enolate precursors and conventional alkyl halides as competitive alkylating agents and the isolation of 1,5-dicarbonyl products resulting from conjugate additions that do not restore the aromatic system. PMID:25906358

  4. "Ipsilateral, high, single-hand, sideways"-Ruijin rule for camera assistant in uniportal video-assisted thoracoscopic surgery.

    PubMed

    Gao, Taotao; Xiang, Jie; Jin, Runsen; Zhang, Yajie; Wu, Han; Li, Hecheng

    2016-10-01

    Camera assistant plays a very important role in uniportal video-assisted thoracoscopic surgery (VATS), who acts as the eye of the surgeon, providing the VATS team with a stable and clear operating view. Thus, a good assistant should cooperate with surgeon and manipulate the camera expertly, to ensure eye-hand coordination. We have performed more than 100 uniportal VATS in the Department Of Thoracic Surgery in Ruijin Hospital. Based on our experiences, we summarized the method of holding camera, known as "ipsilateral, high, single-hand, sideways", which largely improves the comfort and fluency of surgery.

  5. Transport systems research vehicle color display system operations manual

    NASA Technical Reports Server (NTRS)

    Easley, Wesley C.; Johnson, Larry E.

    1989-01-01

    A recent upgrade of the Transport Systems Research Vehicle operated by the Advanced Transport Operating Systems Program Office at the NASA Langley Research Center has resulted in an all-glass panel in the research flight deck. Eight ARINC-D size CRT color displays make up the panel. A major goal of the display upgrade effort was ease of operation and maintenance of the hardware while maintaining versatility needed for flight research. Software is the key to this required versatility and will be the area demanding the most detailed technical design expertise. This document is is intended to serve as a single source of quick reference information needed for routine operation and system level maintenance. Detailed maintenance and modification of the display system will require specific design documentation and must be accomplished by individuals with specialized knowledge and experience.

  6. [The treatment of extremity bone fractures in the cases of combined injuries].

    PubMed

    Peshekhonov, E V; Galin, V I; Zudilin, A V; Zubok, D N

    2006-12-01

    The experience of treatment of 76 injured with fractures of two or more extremities in combination with affection of other anatomical areas (head, abdomen, breast, pelvis) was summarized. The extrafocal osteosynthesis was preferable because this method is characterized by low traumatism, minimal blood loss, adequate reposition, stable immobilization and possibility of early load in the apparatus of external fixation. Immersed osteosynthesis is used with great caution as it can cause the development of fat embolism. One-stage operations were performed in 26.3% victims. Their treatment periods were significantly shorter than during the multi-stage operations. One-stage operations for polytrauma have the following advantages over the multi-stage operations: single narcosis, simplified treatment in reanimation department, one post-operation period, quick rehabilitation and economic benefit. The extrafocal osteosynthesis causes less purulent complications.

  7. Perioperative strategies and technical modifications to the Nuss repair for pectus excavatum in pediatric patients: a large volume, single institution experience.

    PubMed

    Sacco Casamassima, Maria Grazia; Goldstein, Seth D; Salazar, Jose H; McIltrot, Kimberly H; Abdullah, Fizan; Colombani, Paul M

    2014-04-01

    The safety and efficacy of minimally invasive pectus excavatum repair have been demonstrated over the last twenty years. However, technical details and perioperative management strategies continue to be debated. The aim of the present study is to review a large single-institution experience with the modified Nuss procedure. A retrospective review was performed of patients who underwent primary pectus excavatum repair at a single tertiary hospital via a modified Nuss procedure that included: no thoracoscopy, retrosternal dissection achieved via a left-to-right thoracic approach, four-point stabilization of the bar, and no routine epidural analgesia. Data collected included demographics, preoperative symptoms, operative characteristics, hospital charges and postoperative outcomes. A total of 336 pediatric patients were identified. No cardiac perforations occurred and the rate of pericarditis was 0.6%. Contemporary rates of bar displacement have fallen to 1.2%. Routine use of chlorhexidine scrub reduced superficial site infections to 0.7%. Two patients (0.6%) with severe recurrence required reoperation. Bars were removed after an average period of 31.7(SD 13.2) months, with satisfactory cosmetic and functional results in 94.9% of cases. We report here a single-institution large volume experience, including modifications to the Nuss procedure that make the technique simpler and safer, improve results, and minimize hospital charges. Copyright © 2014 Elsevier Inc. All rights reserved.

  8. Early outcomes of transcatheter aortic valve replacement in patients with severe aortic stenosis: single center experience

    PubMed Central

    Bozkurt, Engin; Keleş, Telat; Durmaz, Tahir; Akçay, Murat; Ayhan, Hüseyin; Bayram, Nihal Akar; Aslan, Abdullah Nabi; Baştuğ, Serdal; Bilen, Emine

    2014-01-01

    Introduction Transcatheter aortic valve implantation is a promising alternative to high risk surgical aortic valve replacement. The procedure is mainly indicated in patients with severe symptomatic aortic stenosis who cannot undergo surgery or who are at very high surgical risk. Aim Description early results of our single-center experience with balloon expandable aortic valve implantation. Material and methods Between July 2011 and August 2012, we screened in total 75 consecutive patients with severe aortic stenosis and high risk for surgery. Twenty-one of them were found ineligible for transcatheter aortic valve implantation (TAVI) because of various reasons, and finally we treated a total of 54 patients with symptomatic severe aortic stenosis (AS) who could not be treated by open heart surgery (inoperable) because of high-risk criteria. The average age of the patients was 77.4 ±7.1; 27.8% were male and 72.2% were female. The number of patients in NYHA class II was 7 while the number of patients in class III and class IV was 47. Results The average mortality score of patients according to the STS scoring system was 8.5%. Pre-implantation mean and maximal aortic valve gradients were measured as 53.2 ±14.1 mm Hg and 85.5 ±18.9 mm Hg, respectively. Post-implantation mean and maximal aortic valve gradients were 9.0 ±3.0 and 18.2 ±5.6, respectively (p < 0.0001). The left ventricular ejection fraction was calculated as 54.7 ±14.4% before the operation and 58.0 ±11.1% after the operation (p < 0.0001). The duration of discharge after the operation was 5.29 days, and a statistically significant correlation between the duration of discharge after the operation and STS was found (r = 0385, p = 0.004). Conclusions We consider that with decreasing cost and increasing treatment experience, TAVI will be used more frequently in broader indications. Our experience with TAVI using the Edwards-Sapien XT (Edwards Lifesciences, Irvine, CA) devices suggests that this is an effective and relatively safe procedure for the treatment of severe aortic stenosis in suitable patients. PMID:25061453

  9. Focused RBCC Experiments: Two-Rocket Configuration Experiments and Hydrocarbon/Oxygen Rocket Ejector Experiments

    NASA Technical Reports Server (NTRS)

    Santoro, Robert J.; Pal, Sibtosh

    2003-01-01

    This addendum report documents the results of two additional efforts for the Rocket Based Combined Cycle (RBCC) rocket-ejector mode research work carried out at the Penn State Propulsion Engineering Research Center in support of NASA s technology development efforts for enabling 3 d generation Reusable Launch Vehicles (RLV). The tasks reported here build on an earlier NASA MSFC funded research program on rocket ejector investigations. The first task investigated the improvements of a gaseous hydrogen/oxygen twin thruster RBCC rocket ejector system over a single rocket system. The second task investigated the performance of a hydrocarbon (liquid JP-7)/gaseous oxygen single thruster rocket-ejector system. To gain a systematic understanding of the rocket-ejector s internal fluid mechanic/combustion phenomena, experiments were conducted with both direct-connect and sea-level static diffusion and afterburning (DAB) configurations for a range of rocket operating conditions. For all experimental conditions, overall system performance was obtained through global measurements of wall static pressure profiles, heat flux profiles and engine thrust. Detailed mixing and combustion information was obtained through Raman spectroscopy measurements of major species (gaseous oxygen, hydrogen, nitrogen and water vapor) for the gaseous hydrogen/oxygen rocket ejector experiments.

  10. Morbidity and mortality associated with creation of elastase-induced saccular aneurysms in a rabbit model

    PubMed Central

    Lewis, Debra A; Ding, Yong Hong; Dai, Daying; Kadirvel, Ramanathan; Danielson, Mark A; Cloft, Harry J; Kallmes, David F

    2008-01-01

    Background and Purpose Elastase-induced aneurysms in rabbits have been proposed as a useful preclinical tool for device development. The object of this study is to report rates of morbidity and mortality associated with creation and embolization of the elastase-induced rabbit aneurysm, and to assess the impact of operator experience on these rates. Methods Elastase-induced model aneurysms were created in New Zealand White rabbits (n=700). One neuroradiologist/investigator, naïve to the aneurysm creation procedure at the outset of the experiments, performed all surgeries. All morbidity and deaths related to aneurysm creation (n=700) and embolization procedures (n=529) were categorized into acute and chronic deaths. Data were analyzed with single regression analysis and ANOVA. To assess the impact of increasing operator experience, the number of animals was broken into 50 animal increments. Results There were 121 (17%) deaths among 700 subjects. Among 700 aneurysm creation procedures, 59 deaths (8.4%) were noted. Among 529 aneurysm embolization procedures, 43 deaths (8.1%) were noted. Nineteen additional deaths (2.7% of 700 subjects) were unrelated to procedures. Simple regression indicated mortality associated with procedures diminished with increasing operator experience (R2=0.38; p=0.0180) and that for each 50 rabbit increment mortality is reduced on average by 0.6 percent. Conclusions Mortality rates of approximately 8% are associated with both experimental aneurysm creation and with embolization in the rabbit, elastase-induced aneurysm model. Increasing operator experience is inversely correlated with mortality and the age of the rabbit is positively associated with morbidity. PMID:19001536

  11. Video-Assisted Thoracic Surgical Lobectomy for Lung Cancer: Description of a Learning Curve.

    PubMed

    Yao, Fei; Wang, Jian; Yao, Ju; Hang, Fangrong; Cao, Shiqi; Cao, Yongke

    2017-07-01

    Video-assisted thoracic surgical (VATS) lobectomy is gaining popularity in the treatment of lung cancer. The aim of this study is to investigate the learning curve of VATS lobectomy by using multidimensional methods and to compare the learning curve groups with respect to perioperative clinical outcomes. We retrospectively reviewed a prospective database to identify 67 consecutive patients who underwent VATS lobectomy for lung cancer by a single surgeon. The learning curve was analyzed by using moving average and the cumulative sum (CUSUM) method. With the moving average and CUSUM analyses for the operation time, patients were stratified into two groups, with chronological order defining early and late experiences. Perioperative clinical outcomes were compared between the two learning curve groups. According to the moving average method, the peak point for operation time occurred at the 26th case. The CUSUM method also showed the operation time peak point at the 26th case. When results were compared between early- and late-experience periods, the operation time, duration of chest drainage, and postoperative hospital stay were significantly longer in the early-experience group (cases 1 to 26). The intraoperative estimated blood loss was significantly less in the late-experience group (cases 27 to 67). CUSUM charts showed a decreasing duration of chest drainage after the 36th case and shortening postoperative hospital stay after the 37th case. Multidimensional statistical analyses suggested that the learning curve for VATS lobectomy for lung cancer required ∼26 cases. Favorable intraoperative and postoperative care parameters for VATS lobectomy were observed in the late-experience group.

  12. Effect of minimally invasive surgery fellowship on residents' operative experience.

    PubMed

    Altieri, Maria S; Frenkel, Catherine; Scriven, Richard; Thornton, Deborah; Halbert, Caitlin; Talamini, Mark; Telem, Dana A; Pryor, Aurora D

    2017-01-01

    There is an increased need for surgical trainees to acquire advanced laparoscopic skills as laparoscopy becomes the standard of care in many areas of general surgery. Since the introduction of minimally invasive surgery (MIS) fellowships, there has been a continuing debate as to whether these fellowships adversely affect general surgery resident exposure to laparoscopic cases. The aim of our study was to examine whether the introduction of an MIS fellowship negatively impacts general surgery residents' experience at a single academic center. We describe the changes following establishment of MIS fellowship at an academic center. Resident case log system from the Accreditation Council for Graduate Medical Education was queried to obtain all PGY 1-5 resident operative case logs. Two-year time period preceding and following the institution of an MIS fellowship at our institution in 2012 was compared. P values less than 0.05 were considered statistically significant. Following initiation of the MIS fellowship, an MIS service was established. The service comprised of a fellow, midlevel resident, and intern. Operative experience was examined. From 2010-2012 to 2012-2014, residents logged a total of 272 and 585 complex laparoscopic cases, respectively. There were 43 residents from 2010 to 2013 and 44 residents from 2013 to 2014. When the two time periods were compared, a trend of increased numbers for all procedures was noted, except laparoscopic GYN/genito-urinary procedures. Average percent increase in complex general surgery procedures was 249 ± 179.8 %. Following establishment of a MIS fellowship, reported cases by residents were higher or similar to those reported nationally for laparoscopic procedures. Institution of an MIS fellowship had a favorable effect on general surgery resident operative education at a single academic training center. Residents may benefit from the presence of a fellowship at an academic center because they are able to participate in an increased number of complex laparoscopic cases.

  13. Isotope effects on L-H threshold and confinement in tokamak plasmas

    NASA Astrophysics Data System (ADS)

    Maggi, C. F.; Weisen, H.; Hillesheim, J. C.; Chankin, A.; Delabie, E.; Horvath, L.; Auriemma, F.; Carvalho, I. S.; Corrigan, G.; Flanagan, J.; Garzotti, L.; Keeling, D.; King, D.; Lerche, E.; Lorenzini, R.; Maslov, M.; Menmuir, S.; Saarelma, S.; Sips, A. C. C.; Solano, E. R.; Belonohy, E.; Casson, F. J.; Challis, C.; Giroud, C.; Parail, V.; Silva, C.; Valisa, M.; Contributors, JET

    2018-01-01

    The dependence of plasma transport and confinement on the main hydrogenic ion isotope mass is of fundamental importance for understanding turbulent transport and, therefore, for accurate extrapolations of confinement from present tokamak experiments, which typically use a single hydrogen isotope, to burning plasmas such as ITER, which will operate in deuterium-tritium mixtures. Knowledge of the dependence of plasma properties and edge transport barrier formation on main ion species is critical in view of the initial, low-activation phase of ITER operations in hydrogen or helium and of its implications on the subsequent operation in deuterium-tritium. The favourable scaling of global energy confinement time with isotope mass, which has been observed in many tokamak experiments, remains largely unexplained theoretically. Moreover, the mass scaling observed in experiments varies depending on the plasma edge conditions. In preparation for upcoming deuterium-tritium experiments in the JET tokamak with the ITER-like Be/W Wall (JET-ILW), a thorough experimental investigation of isotope effects in hydrogen, deuterium and tritium plasmas is being carried out, in order to provide stringent tests of plasma energy, particle and momentum transport models. Recent hydrogen and deuterium isotope experiments in JET-ILW on L-H power threshold, L-mode and H-mode confinement are reviewed and discussed in the context of past and more recent isotope experiments in tokamak plasmas, highlighting common elements as well as contrasting observations that have been reported. The experimental findings are discussed in the context of fundamental aspects of plasma transport models.

  14. SMART-1 operations experience and lessons learnt

    NASA Astrophysics Data System (ADS)

    Camino, Octavio; Alonso, Maria; Gestal, Daniel; de Bruin, Jurriaan; Rathsman, Peter; Kugelberg, Joakim; Bodin, Per; Ricken, Sascha; Blake, Rick; Voss, Pablo Pardo; Stagnaro, Luca

    2007-06-01

    SMART-1 is the first of a series of ESA Small Missions for Advance Research and Technology where elements of the platform and the payload technology have been conceived as a demonstration for future cornerstone missions and an early opportunity for science. SMART-1 has also been an opportunity to experiment with new ways of conducting ground operations taking advantage of both increased satellite autonomy and ground automation tools. The paper will focus on three areas: The accumulated performance of the technology demonstration components since launch as the electrical propulsion engine, the triple-junction solar cells, the lithium-ion batteries, the 32 bit CPU ERC32 Single Chip, the CAN bus, the DTU Star Trackers and the complex on-board autonomy. The changes implemented on-board and on the ground during the lunar phase to increase the data return. The pros and contras in some of the choices made for SMART-1, the developments and solutions implemented to mitigate the problems, the tools developed to automate the operations and the distribution of data.

  15. Dark matter spin determination with directional direct detection experiments

    NASA Astrophysics Data System (ADS)

    Catena, Riccardo; Conrad, Jan; Döring, Christian; Ferella, Alfredo Davide; Krauss, Martin B.

    2018-01-01

    If dark matter has spin 0, only two WIMP-nucleon interaction operators can arise as leading operators from the nonrelativistic reduction of renormalizable single-mediator models for dark matter-quark interactions. Based on this crucial observation, we show that about 100 signal events at next generation directional detection experiments can be enough to enable a 2 σ rejection of the spin 0 dark matter hypothesis in favor of alternative hypotheses where the dark matter particle has spin 1 /2 or 1. In this context, directional sensitivity is crucial since anisotropy patterns in the sphere of nuclear recoil directions depend on the spin of the dark matter particle. For comparison, about 100 signal events are expected in a CF4 detector operating at a pressure of 30 torr with an exposure of approximately 26,000 cubic-meter-detector days for WIMPs of 100 GeV mass and a WIMP-fluorine scattering cross section of 0.25 pb. Comparable exposures require an array of cubic meter time projection chamber detectors.

  16. High Temperature Electrolysis using Electrode-Supported Cells

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    J. E. O'Brien; C. M. Stoots

    2010-07-01

    An experimental study is under way to assess the performance of electrode-supported solid-oxide cells operating in the steam electrolysis mode for hydrogen production. The cells currently under study were developed primarily for the fuel cell mode of operation. Results presented in this paper were obtained from single cells, with an active area of 16 cm2 per cell. The electrolysis cells are electrode-supported, with yttria-stabilized zirconia (YSZ) electrolytes (~10 µm thick), nickel-YSZ steam/hydrogen electrodes (~1400 µm thick), and manganite (LSM) air-side electrodes (~90 µm thick). The purpose of the present study was to document and compare the performance and degradation ratesmore » of these cells in the fuel cell mode and in the electrolysis mode under various operating conditions. Initial performance was documented through a series of DC potential sweeps and AC impedance spectroscopy measurements. Degradation was determined through long-duration testing, first in the fuel cell mode, then in the electrolysis mode over more than 500 hours of operation. Results indicate accelerated degradation rates in the electrolysis mode compared to the fuel cell mode, possibly due to electrode delamination. The paper also includes details of the single-cell test apparatus developed specifically for these experiments.« less

  17. Variable recruitment fluidic artificial muscles: modeling and experiments

    NASA Astrophysics Data System (ADS)

    Bryant, Matthew; Meller, Michael A.; Garcia, Ephrahim

    2014-07-01

    We investigate taking advantage of the lightweight, compliant nature of fluidic artificial muscles to create variable recruitment actuators in the form of artificial muscle bundles. Several actuator elements at different diameter scales are packaged to act as a single actuator device. The actuator elements of the bundle can be connected to the fluidic control circuit so that different groups of actuator elements, much like individual muscle fibers, can be activated independently depending on the required force output and motion. This novel actuation concept allows us to save energy by effectively impedance matching the active size of the actuators on the fly based on the instantaneous required load. This design also allows a single bundled actuator to operate in substantially different force regimes, which could be valuable for robots that need to perform a wide variety of tasks and interact safely with humans. This paper proposes, models and analyzes the actuation efficiency of this actuator concept. The analysis shows that variable recruitment operation can create an actuator that reduces throttling valve losses to operate more efficiently over a broader range of its force-strain operating space. We also present preliminary results of the design, fabrication and experimental characterization of three such bioinspired variable recruitment actuator prototypes.

  18. The learning curve of laparoendoscopic single-Site (LESS) fundoplication: definable, short, and safe.

    PubMed

    Ross, Sharona B; Choung, Edward; Teta, Anthony F; Colibao, Lotiffa; Luberice, Kenneth; Paul, Harold; Rosemurgy, Alexander S

    2013-01-01

    This study of laparoendoscopic single-site (LESS) fundoplication for gastroesophageal reflux disease was undertaken to determine the "learning curve" for implementing LESS fundoplication. One hundred patients, 38% men, with a median age of 61 years and median body mass index of 26 kg/m(2) , underwent LESS fundoplications. The operative times, placement of additional trocars, conversions to "open" operations, and complications were compared among patient quartiles to establish a learning curve. Median data are reported. The median operative times and complications did not differ among 25-patient cohorts. Additional trocars were placed in 27% of patients, 67% of whom were in the first 25-patient cohort. Patients undergoing LESS fundoplication had a dramatic relief in the frequency and severity of all symptoms of reflux across all cohorts equally (P < .05), particularly for heartburn and regurgitation, without causing dysphagia. LESS fundoplication ameliorates symptoms of gastroesophageal reflux disease without apparent scarring. Notably, few operations required additional trocars after the first 25-patient cohort. Patient selection became more inclusive (eg, more "redo" fundoplications) with increasing experience, whereas operative times and complications remained relatively unchanged. The learning curve of LESS fundoplication is definable, short, and safe. We believe that patients will seek LESS fundoplication because of the efficacy and superior cosmetic outcomes; surgeons will need to meet this demand.

  19. Reconnection Scaling Experiment (RSX): Magnetic Reconnection in Linear Geometry

    NASA Astrophysics Data System (ADS)

    Intrator, T.; Sovinec, C.; Begay, D.; Wurden, G.; Furno, I.; Werley, C.; Fisher, M.; Vermare, L.; Fienup, W.

    2001-10-01

    The linear Reconnection Scaling Experiment (RSX) at LANL is a new experiment that can create MHD relevant plasmas to look at the physics of magnetic reconnection. This experiment can scale many relevant parameters because the guns that generate the plasma and current channels do not depend on equilibrium or force balance for startup. We describe the experiment and initial electrostatic and magnetic probe data. Two parallel current channels sweep down a long plasma column and probe data accumulated over many shots gives 3D movies of magnetic reconnection. Our first data tries to define an operating regime free from kink instabilities that might otherwise confuse the data and shot repeatability. We compare this with MHD 2 fluid NIMROD simulations of the single current channel kink stability boundary for a variety of experimental conditions.

  20. An Improved Azimuth Angle Estimation Method with a Single Acoustic Vector Sensor Based on an Active Sonar Detection System.

    PubMed

    Zhao, Anbang; Ma, Lin; Ma, Xuefei; Hui, Juan

    2017-02-20

    In this paper, an improved azimuth angle estimation method with a single acoustic vector sensor (AVS) is proposed based on matched filtering theory. The proposed method is mainly applied in an active sonar detection system. According to the conventional passive method based on complex acoustic intensity measurement, the mathematical and physical model of this proposed method is described in detail. The computer simulation and lake experiments results indicate that this method can realize the azimuth angle estimation with high precision by using only a single AVS. Compared with the conventional method, the proposed method achieves better estimation performance. Moreover, the proposed method does not require complex operations in frequencydomain and achieves computational complexity reduction.

  1. Optical frequency comb profilometry using a single-pixel camera composed of digital micromirror devices.

    PubMed

    Pham, Quang Duc; Hayasaki, Yoshio

    2015-01-01

    We demonstrate an optical frequency comb profilometer with a single-pixel camera to measure the position and profile of an object's surface that exceeds far beyond light wavelength without 2π phase ambiguity. The present configuration of the single-pixel camera can perform the profilometry with an axial resolution of 3.4 μm at 1 GHz operation corresponding to a wavelength of 30 cm. Therefore, the axial dynamic range was increased to 0.87×105. It was found from the experiments and computer simulations that the improvement was derived from higher modulation contrast of digital micromirror devices. The frame rate was also increased to 20 Hz.

  2. Discrete mode laser diodes for FTTH/PON applications up to 10 Gbit/s

    NASA Astrophysics Data System (ADS)

    O'Carroll, John; Phelan, Richard; Kelly, Brian; Byrne, Diarmuid; Latkowski, Sylwester; Anandarajah, Prince M.; Barry, Liam P.

    2012-06-01

    Discrete Mode Laser Diodes (DMLDs) present an economic approach with a focus on high volume manufacturability of single mode lasers using a single step fabrication process. We report on a DMLD designed for operation in the 1550 nm window with high Side Mode Suppression Ratio (SMSR) over a wide temperature tuning range of -20 °C < T < 95 °C. Direct modulation rates as high as 10 Gbit/s are demonstrated at both 1550 nm and 1310 nm. Transmission experiments were also carried out over single mode fibre at both wavelengths. Using dispersion pre-compensation transmission from 0 to 60 km is demonstrated at 1550 nm with a maximum power penalty measured at 60 km of 3.6 dB.

  3. Quantum dots in single electron transistors with ultrathin silicon-on-insulator structures

    NASA Astrophysics Data System (ADS)

    Ihara, S.; Andreev, A.; Williams, D. A.; Kodera, T.; Oda, S.

    2015-07-01

    We report on fabrication and transport properties of lithographically defined single quantum dots (QDs) in single electron transistors with ultrathin silicon-on-insulator (SOI) substrate. We observed comparatively large charging energy E C ˜ 20 meV derived from the stability diagram at a temperature of 4.2 K. We also carried out three-dimensional calculations of the capacitance matrix and transport properties through the QD for the real structure geometry and found an excellent quantitative agreement with experiment of the calculated main parameters of stability diagram (charging energy, period of Coulomb oscillations, and asymmetry of the diamonds). The obtained results confirm fabrication of well-defined integrated QDs as designed with ultrathin SOI that makes it possible to achieve relatively large QD charging energies, which is useful for stable and high temperature operation of single electron devices.

  4. Spurious-Mode Control of Same-Phase Drive-Type Ultrasonic Motor

    NASA Astrophysics Data System (ADS)

    Aoyagi, Manabu; Watanabe, Hiroyuki; Tomikawa, Yoshiro; Takano, Takehiro

    2002-05-01

    A same-phase drive-type ultrasonic motor requires a single power source for its operation. In particular, self-oscillation driving is useful for driving a small ultrasonic motor. This type of ultrasonic motor has a spurious mode close to the operation frequency on its stator vibrator. The spurious vibration mode affects the oscillation frequency of a self-oscillation drive circuit. Hence the spurious vibration mode should be restrained or moved away from the neighborhood of the operation frequency. In this paper, we report that an inductor connected at an electrical control terminal provided on standby electrodes for the reverse rotation operation controls only the spurious vibration mode. The effect of an inductor connected at the control terminal was clarified by the simulation of an equivalent circuit and some experiments.

  5. Quantitative analysis of a spinal surgeon's learning curve for scoliosis surgery.

    PubMed

    Ryu, K J; Suh, S W; Kim, H W; Lee, D H; Yoon, Y; Hwang, J H

    2016-05-01

    The aim of this study was a quantitative analysis of a surgeon's learning curve for scoliosis surgery and the relationship between the surgeon's experience and post-operative outcomes, which has not been previously well described. We have investigated the operating time as a function of the number of patients to determine a specific pattern; we analysed factors affecting the operating time and compared intra- and post-operative outcomes. We analysed 47 consecutive patients undergoing scoliosis surgery performed by a single, non-trained scoliosis surgeon. Operating time was recorded for each of the four parts of the procedures: dissection, placement of pedicle screws, reduction of the deformity and wound closure. The median operating time was 310 minutes (interquartile range 277.5 to 432.5). The pattern showed a continuous decreasing trend in operating time until the patient number reached 23 to 25, after which it stabilised with fewer patient-dependent changes. The operating time was more affected by the patient number (r =- 0.75) than the number of levels fused (r = 0.59). Blood loss (p = 0.016) and length of stay in hospital (p = 0.012) were significantly less after the operating time stabilised. Post-operative functional outcome scores and the rate of complications showed no significant differences. We describe a detailed learning curve for scoliosis surgery based on a single surgeon's practise, providing useful information for novice scoliosis surgeons and for those responsible for training in spinal surgery. Cite this article: Bone Joint J 2016;98-B:679-85. ©2016 The British Editorial Society of Bone & Joint Surgery.

  6. An analysis on combined GPS/COMPASS data quality and its effect on single point positioning accuracy under different observing conditions

    NASA Astrophysics Data System (ADS)

    Cai, Changsheng; Gao, Yang; Pan, Lin; Dai, Wujiao

    2014-09-01

    With the rapid development of the COMPASS system, it is currently capable of providing regional navigation services. In order to test its data quality and performance for single point positioning (SPP), experiments have been conducted under different observing conditions including open sky, under trees, nearby a glass wall, nearby a large area of water, under high-voltage lines and under a signal transmitting tower. To assess the COMPASS data quality, the code multipath, cycle slip occurrence rate and data availability were analyzed and compared to GPS data. The datasets obtained from the experiments have also been utilized to perform combined GPS/COMPASS SPP on an epoch-by-epoch basis using unsmoothed single-frequency code observations. The investigation on the regional navigation performance aims at low-accuracy applications and all tests are made in Changsha, China, using the “SOUTH S82-C” GPS/COMPASS receivers. The results show that adding COMPASS observations can significantly improve the positioning accuracy of single-frequency GPS-only SPP in environments with limited satellite visibility. Since the COMPASS system is still in an initial operational stage, all results are obtained based on a fairly limited amount of data.

  7. Flight Test Results from Real-Time Relative Global Positioning System Flight Experiment on STS-69

    NASA Technical Reports Server (NTRS)

    Park, Young W.; Brazzel, Jack P., Jr.; Carpenter, J. Russell; Hinkel, Heather D.; Newman, James H.

    1996-01-01

    A real-time global positioning system (GPS) Kalman filter has been developed to support automated rendezvous with the International Space Station (ISS). The filter is integrated with existing Shuttle rendezvous software running on a 486 laptop computer under Windows. In this work, we present real-time and postflight results achieved with the filter on STS-69. The experiment used GPS data from an Osborne/Jet propulsion Laboratory TurboRouge receiver carried on the Wake Shield Facility (WSF) free flyer and a Rockwell Collins 3M receiver carried on the Orbiter. Real time filter results, processed onboard the Shuttle and replayed in near-time on the ground, are based on single vehicle mode operation and on 5 to 20 minute snapshots of telemetry provided by WSF for dual-vehicle mode operation. The Orbiter and WSF state vectors calculated using our filter compare favorably with precise reference orbits determined by the University of Texas Center for Space Research. The lessons learned from this experiment will be used in conjunction with future experiments to mitigate the technology risk posed by automated rendezvous and docking to the ISS.

  8. Small stack performance of intermediate temperature-operating solid oxide fuel cells using stainless steel interconnects and anode-supported single cell

    NASA Astrophysics Data System (ADS)

    Bae, Joongmyeon; Lim, Sungkwang; Jee, Hyunjin; Kim, Jung Hyun; Yoo, Young-Sung; Lee, Taehee

    We are developing 1 kW class solid oxide fuel cell (SOFC) system for residential power generation (RPG) application supported by Korean Government. Anode-supported single cells with thin electrolyte layer of YSZ (yttria-stabilized zirconia) or ScSZ (scandia-stabilized zirconia) for intermediate temperature operation (650-750 °C), respectively, were fabricated and small stacks were built and evaluated. The LSCF/ScSZ/Ni-YSZ single cell showed performance of 543 mW cm -2 at 650 °C and 1680 mW cm -2 at 750 °C. The voltage of 15-cell stack based on 5 cm × 5 cm single cell (LSM/YSZ/Ni-YSZ) at 150 mW was 12.5 V in hydrogen as fuel of 120 sccm per cell at 750 °C and decreased to about 10.9 V at 500 h operation time. A 5-cell stack based on the LSCF/YSZ/FL/Ni-YSZ showed the maximum power density of 30 W, 25 W and 20 W at 750 °C, 700 °C and 650 °C, respectively. LSCF/ScSZ/Ni-YSZ-based stack showed better performance than LSCF/YSZ/Ni-YSZ stack from the experiment temperature range. I- V characteristics by using hydrogen gas and reformate gas of methane as fuel were investigated at 750 °C in LSCF/ScSZ/FL/Ni-YSZ-based 5-cell stack.

  9. The Influence of Intersections on Fuel Consumption in Urban Arterial Road Traffic: A Single Vehicle Test in Harbin, China

    PubMed Central

    Wu, Lina; Ci, Yusheng; Chu, Jiangwei; Zhang, Hongsheng

    2015-01-01

    The calculating method for fuel consumption (FC) was put forward and calibrated and the characteristics of the fuel consumption on intersections were analyzed based on 18 groups of vehicular operating data which were acquired from the test experiment of a single vehicle along the urban arterial roads in Harbin, China. The results obtained show that 50.36% of the fuel consumption for the test vehicle was used at the area of intersections compared with 28.9% of the influencing distance and 68.5% of the running time; and 78.4% of them was burnt at the stages of acceleration and idling. Meanwhile, the type (c) of the vehicular operating status was illustrated to be the worst way of reducing fuel consumption, the causes were analyzed and four improvement strategies were put forward. PMID:26367012

  10. The LCLS variable-energy hard X-ray single-shot spectrometer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rich, David; Zhu, Diling; Turner, James

    2016-01-01

    The engineering design, implementation, operation and performance of the new variable-energy hard X-ray single-shot spectrometer (HXSSS) for the LCLS free-electron laser (FEL) are reported. The HXSSS system is based on a cylindrically bent Si thin crystal for dispersing the incident polychromatic FEL beam. A spatially resolved detector system consisting of a Ce:YAG X-ray scintillator screen, an optical imaging system and a low-noise pixelated optical camera is used to record the spectrograph. The HXSSS provides single-shot spectrum measurements for users whose experiments depend critically on the knowledge of the self-amplified spontaneous emission FEL spectrum. It also helps accelerator physicists for themore » continuing studies and optimization of self-seeding, various improved mechanisms for lasing mechanisms, and FEL performance improvements. The designed operating energy range of the HXSSS is from 4 to 20 keV, with the spectral range of order larger than 2% and a spectral resolution of 2 × 10 -5or better. Those performance goals have all been achieved during the commissioning of the HXSSS.« less

  11. The LCLS variable-energy hard X-ray single-shot spectrometer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rich, David; Zhu, Diling; Turner, James

    The engineering design, implementation, operation and performance of the new variable-energy hard X-ray single-shot spectrometer (HXSSS) for the LCLS free-electron laser (FEL) are reported. The HXSSS system is based on a cylindrically bent Si thin crystal for dispersing the incident polychromatic FEL beam. A spatially resolved detector system consisting of a Ce:YAG X-ray scintillator screen, an optical imaging system and a low-noise pixelated optical camera is used to record the spectrograph. The HXSSS provides single-shot spectrum measurements for users whose experiments depend critically on the knowledge of the self-amplified spontaneous emission FEL spectrum. It also helps accelerator physicists for themore » continuing studies and optimization of self-seeding, various improved mechanisms for lasing mechanisms, and FEL performance improvements. The designed operating energy range of the HXSSS is from 4 to 20 keV, with the spectral range of order larger than 2% and a spectral resolution of 2 × 10 -5or better. Those performance goals have all been achieved during the commissioning of the HXSSS.« less

  12. Differential recruitment of brain networks in single-digit addition and multiplication: Evidence from EEG oscillations in theta and lower alpha bands.

    PubMed

    Wang, Lihan; Gan, John Q; Zhang, Li; Wang, Haixian

    2018-06-01

    Previous neuroimaging research investigating dissociation between single-digit addition and multiplication has suggested that the former placed more reliance on the visuo-spatial processing whereas the latter on the verbal processing. However, there has been little exploration into the disassociation in spatio-temporal dynamics of the oscillatory brain activity in specific frequency bands during the two arithmetic operations. To address this issue, the electroencephalogram (EEG) data were recorded from 19 participants engaged in a delayed verification arithmetic task. By analyzing oscillatory EEG activity in theta (5-7 Hz) and lower alpha frequency (9-10 Hz) bands, we found different patterns of oscillatory brain activity between single-digit addition and multiplication during the early processing stage (0-400 ms post-operand onset). Experiment results in this study showed a larger phasic increase of theta-band power for addition than for multiplication in the midline and the right frontal and central regions during the operator and operands presentation intervals, which was extended to the right parietal and the right occipito-temporal regions during the interval immediately after the operands presentation. In contrast, during multiplication higher phase-locking in lower alpha band was evident in the centro-parietal regions during the operator presentation, which was extended to the left fronto-central and anterior regions during the operands presentation. Besides, we found stronger theta phase synchrony between the parietal areas and the right occipital areas for single-digit addition than for multiplication during operands encoding. These findings of oscillatory brain activity extend the previous observations on functional dissociation between the two arithmetic operations. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. Experiments on planetary ices at UCL

    NASA Astrophysics Data System (ADS)

    Grindrod, P. M.; Fortes, A. D.; Wood, I. G.; Dobson, D.; Sammonds, P. R.; Stone-Drake, L.; Vocadlo, L.

    2007-08-01

    Using a suite of techniques and equipment, we conduct several different types of experiments on planetary ices at UCL. Samples are prepared in the Ice Physics Laboratory, which consists of a 5 chamber complex of inter-connected cold rooms, controllable from +30 to -30 deg C. Within this laboratory we have a functioning triaxial deformation cell operating at low temperature (down to -90 deg C) and high pressures (300 MPa), an Automatic Ice Fabric Analyser (AIFA) and a low-temperature microscope with CCD output. Polycrystalline samples, 40mm diameter by 100mm long, are compressed in the triaxial rig with a confining pressure; single crystal specimens are compressed in a separate uniaxial creep rig which operates at zero confining pressure for surface studies. A cold stage is also available for study of ice microstructural studies on our new Jeol JSM-6480LV SEM, which also allows tensile, compression and/or bending tests, with load ranges from less than 2N to 5000N. Finally, we also use a cold stage on a new PANalytical, X'pert PRO MPD, high resolution powder diffractometer to study the structure and phase behaviour of icy materials. Recent highlights of our work include: (1) derivation of a manufacturing process for methane clathrate at low temperatures, analysed in the X-Ray Diffraction Laboratory, for future rheological experiments, (2) analysed the growth behaviour of MS11, (3) refurbished and commenced calibration tests on the triaxial deformation cell using ice Ih, and (4) performed creep tests on gypsum and epsomite using the single crystal deformation cell. Further experiments will build on these preliminary results.

  14. Boson Sampling with Single-Photon Fock States from a Bright Solid-State Source.

    PubMed

    Loredo, J C; Broome, M A; Hilaire, P; Gazzano, O; Sagnes, I; Lemaitre, A; Almeida, M P; Senellart, P; White, A G

    2017-03-31

    A boson-sampling device is a quantum machine expected to perform tasks intractable for a classical computer, yet requiring minimal nonclassical resources as compared to full-scale quantum computers. Photonic implementations to date employed sources based on inefficient processes that only simulate heralded single-photon statistics when strongly reducing emission probabilities. Boson sampling with only single-photon input has thus never been realized. Here, we report on a boson-sampling device operated with a bright solid-state source of single-photon Fock states with high photon-number purity: the emission from an efficient and deterministic quantum dot-micropillar system is demultiplexed into three partially indistinguishable single photons, with a single-photon purity 1-g^{(2)}(0) of 0.990±0.001, interfering in a linear optics network. Our demultiplexed source is between 1 and 2 orders of magnitude more efficient than current heralded multiphoton sources based on spontaneous parametric down-conversion, allowing us to complete the boson-sampling experiment faster than previous equivalent implementations.

  15. Automated Operations Development for Advanced Exploration Systems

    NASA Technical Reports Server (NTRS)

    Haddock, Angie; Stetson, Howard K.

    2012-01-01

    Automated space operations command and control software development and its implementation must be an integral part of the vehicle design effort. The software design must encompass autonomous fault detection, isolation, recovery capabilities and also provide single button intelligent functions for the crew. Development, operations and safety approval experience with the Timeliner system on-board the International Space Station (ISS), which provided autonomous monitoring with response and single command functionality of payload systems, can be built upon for future automated operations as the ISS Payload effort was the first and only autonomous command and control system to be in continuous execution (6 years), 24 hours a day, 7 days a week within a crewed spacecraft environment. Utilizing proven capabilities from the ISS Higher Active Logic (HAL) System [1] , along with the execution component design from within the HAL 9000 Space Operating System [2] , this design paper will detail the initial HAL System software architecture and interfaces as applied to NASA s Habitat Demonstration Unit (HDU) in support of the Advanced Exploration Systems, Autonomous Mission Operations project. The development and implementation of integrated simulators within this development effort will also be detailed and is the first step in verifying the HAL 9000 Integrated Test-Bed Component [2] designs effectiveness. This design paper will conclude with a summary of the current development status and future development goals as it pertains to automated command and control for the HDU.

  16. Automated Operations Development for Advanced Exploration Systems

    NASA Technical Reports Server (NTRS)

    Haddock, Angie T.; Stetson, Howard

    2012-01-01

    Automated space operations command and control software development and its implementation must be an integral part of the vehicle design effort. The software design must encompass autonomous fault detection, isolation, recovery capabilities and also provide "single button" intelligent functions for the crew. Development, operations and safety approval experience with the Timeliner system onboard the International Space Station (ISS), which provided autonomous monitoring with response and single command functionality of payload systems, can be built upon for future automated operations as the ISS Payload effort was the first and only autonomous command and control system to be in continuous execution (6 years), 24 hours a day, 7 days a week within a crewed spacecraft environment. Utilizing proven capabilities from the ISS Higher Active Logic (HAL) System, along with the execution component design from within the HAL 9000 Space Operating System, this design paper will detail the initial HAL System software architecture and interfaces as applied to NASA's Habitat Demonstration Unit (HDU) in support of the Advanced Exploration Systems, Autonomous Mission Operations project. The development and implementation of integrated simulators within this development effort will also be detailed and is the first step in verifying the HAL 9000 Integrated Test-Bed Component [2] designs effectiveness. This design paper will conclude with a summary of the current development status and future development goals as it pertains to automated command and control for the HDU.

  17. Optimization of the Brillouin operator on the KNL architecture

    NASA Astrophysics Data System (ADS)

    Dürr, Stephan

    2018-03-01

    Experiences with optimizing the matrix-times-vector application of the Brillouin operator on the Intel KNL processor are reported. Without adjustments to the memory layout, performance figures of 360 Gflop/s in single and 270 Gflop/s in double precision are observed. This is with Nc = 3 colors, Nv = 12 right-hand-sides, Nthr = 256 threads, on lattices of size 323 × 64, using exclusively OMP pragmas. Interestingly, the same routine performs quite well on Intel Core i7 architectures, too. Some observations on the much harderWilson fermion matrix-times-vector optimization problem are added.

  18. In situ observations of water production and distribution in an operating H2/O2 PEM fuel cell assembly using 1H NMR microscopy.

    PubMed

    Feindel, Kirk W; LaRocque, Logan P-A; Starke, Dieter; Bergens, Steven H; Wasylishen, Roderick E

    2004-09-22

    Proton NMR imaging was used to investigate in situ the distribution of water in a polymer electrolyte membrane fuel cell operating on H2 and O2. In a single experiment, water was monitored in the gas flow channels, the membrane electrode assembly, and in the membrane surrounding the catalysts. Radial gradient diffusion removes water from the catalysts into the surrounding membrane. This research demonstrates the strength of 1H NMR microscopy as an aid for designing fuel cells to optimize water management.

  19. Evaluating Coding Accuracy in General Surgery Residents' Accreditation Council for Graduate Medical Education Procedural Case Logs.

    PubMed

    Balla, Fadi; Garwe, Tabitha; Motghare, Prasenjeet; Stamile, Tessa; Kim, Jennifer; Mahnken, Heidi; Lees, Jason

    The Accreditation Council for Graduate Medical Education (ACGME) case log captures resident operative experience based on Current Procedural Terminology (CPT) codes and is used to track operative experience during residency. With increasing emphasis on resident operative experiences, coding is more important than ever. It has been shown in other surgical specialties at similar institutions that the residents' ACGME case log may not accurately reflect their operative experience. What barriers may influence this remains unclear. As the only objective measure of resident operative experience, an accurate case log is paramount in representing one's operative experience. This study aims to determine the accuracy of procedural coding by general surgical residents at a single institution. Data were collected from 2 consecutive graduating classes of surgical residents' ACGME case logs from 2008 to 2014. A total of 5799 entries from 7 residents were collected. The CPT codes entered by residents were compared to departmental billing records submitted by the attending surgeon for each procedure. Assigned CPT codes by institutional American Academy of Professional Coders certified abstract coders were considered the "gold standard." A total of 4356 (75.12%) of 5799 entries were identified in billing records. Excel 2010 and SAS 9.3 were used for analysis. In the event of multiple codes for the same patient, any match between resident codes and billing record codes was considered a "correct" entry. A 4-question survey was distributed to all current general surgical residents at our institution for feedback on coding habits, limitations to accurate coding, and opinions on ACGME case log representation of their operative experience. All 7 residents had a low percentage of correctly entered CPT codes. The overall accuracy proportion for all residents was 52.82% (range: 43.32%-60.07%). Only 1 resident showed significant improvement in accuracy during his/her training (p = 0.0043). The survey response rate was 100%. Survey results indicated that inability to find the precise code within the ACGME search interface and unfamiliarity with available CPT codes were by far the most common perceived barriers to accuracy. Survey results also indicated that most residents (74%) believe that they code accurately most of the time and agree that their case log would accurately represent their operative experience (66.6%). This is the first study to evaluate correctness of residents' ACGME case logs in general surgery. The degree of inaccuracy found here necessitates further investigation into the etiology of these discrepancies. Instruction on coding practices should also benefit the residents after graduation. Optimizing communication among attendings and residents, improving ACGME coding search interface, and implementing consistent coding practices could improve accuracy giving a more realistic view of residents' operative experience. Published by Elsevier Inc.

  20. Revisiting the pancreaticoduodenectomy for trauma: a single institution's experience.

    PubMed

    Thompson, Callie M; Shalhub, Sherene; DeBoard, Zachary M; Maier, Ronald V

    2013-08-01

    Major pancreaticoduodenal injury can be devastating even if identified and controlled early. To date, both morbidity and mortality have resisted the improvements achieved with many other life-threatening injuries, with reported mortalities of 31% to 50%. We sought to elucidate the impact of the initial operation in the management of severe pancreaticoduodenal injury. A retrospective review of all patients presenting to a single Level I trauma center who required pancreaticoduodenectomy for trauma from 1996 to 2010 was performed. We collected demographic and in-hospital data and compared subjects based on their initial operation. Fifteen patients (median age, 29 years; 93% male; median Injury Severity Score [ISS], 35) underwent pancreaticoduodenectomy following blunt (n = 5) or penetrating trauma (n = 10). Twelve patients (80%) underwent damage-control surgery (DCS) with or without the initial stage of Whipple resection as their first operation. Three patients (20%) underwent a complete Whipple procedure, including reconstruction, as their first operation. Overall, 87% of patients (13 of 15) were acidotic, hypothermic, and coagulopathic during their first operation. Average operative time was longer for the completion pancreaticoduodenectomy versus DCS (460 [98] minutes vs. 243 [112] minutes). There were no overall differences in complication rates, although the two patients who did not experience a complication had DCS. In-hospital mortality was 13% (n = 2). We present both the largest series of patients to date who underwent a DCS or staged Whipple procedure for complex pancreaticoduodenal trauma and the largest series with blunt trauma. Using a staged approach, we report the lowest mortality rate for such injuries in the literature, less than half of that reported in the most recent series (33%). Given the frequent occurrence and recognized detrimental impact of acidosis, hypothermia, and coagulopathy in patients with severe pancreaticoduodenal trauma as well as the proven benefits of DCS, we propose that these patients should undergo initial DCS and staged reconstruction.

  1. Teaching Reform of Civil Engineering Materials Course Based on Project-Driven Pedagogy

    NASA Astrophysics Data System (ADS)

    Yidong, Xu; Wei, Chen; WeiguoJian, You; Jiansheng, Shen

    2018-05-01

    In view of the scattered experimental projects in practical courses of civil engineering materials, the poor practical ability of students and the disconnection between practical teaching and theoretical teaching, this paper proposes a practical teaching procedure. Firstly, the single experiment should be offered which emphasizes on improving the students’ basic experimental operating ability. Secondly, the compressive experiment is offered and the overall quality of students can be examined in the form of project team. In order to investigate the effect of teaching reform, the comparative analysis of the students of three grades (2014, 2015 and 2016) majored in civil engineering was conducted. The result shows that the students’ ability of experimental operation is obviously improved by using the project driven method-based teaching reform. Besides, the students’ ability to analyse and solve problems has also been improved.

  2. Technology study of quantum remote sensing imaging

    NASA Astrophysics Data System (ADS)

    Bi, Siwen; Lin, Xuling; Yang, Song; Wu, Zhiqiang

    2016-02-01

    According to remote sensing science and technology development and application requirements, quantum remote sensing is proposed. First on the background of quantum remote sensing, quantum remote sensing theory, information mechanism, imaging experiments and prototype principle prototype research situation, related research at home and abroad are briefly introduced. Then we expounds compress operator of the quantum remote sensing radiation field and the basic principles of single-mode compression operator, quantum quantum light field of remote sensing image compression experiment preparation and optical imaging, the quantum remote sensing imaging principle prototype, Quantum remote sensing spaceborne active imaging technology is brought forward, mainly including quantum remote sensing spaceborne active imaging system composition and working principle, preparation and injection compression light active imaging device and quantum noise amplification device. Finally, the summary of quantum remote sensing research in the past 15 years work and future development are introduced.

  3. Compact, Automated, Frequency-Agile Microspectrofluorimeter

    NASA Technical Reports Server (NTRS)

    Fernandez, Salvador M.; Guignon, Ernest F.

    1995-01-01

    Compact, reliable, rugged, automated cell-culture and frequency-agile microspectrofluorimetric apparatus developed to perform experiments involving photometric imaging observations of single live cells. In original application, apparatus operates mostly unattended aboard spacecraft; potential terrestrial applications include automated or semiautomated diagnosis of pathological tissues in clinical laboratories, biomedical instrumentation, monitoring of biological process streams, and portable instrumentation for testing biological conditions in various environments. Offers obvious advantages over present laboratory instrumentation.

  4. Twisted Radio Waves and Twisted Thermodynamics

    PubMed Central

    Kish, Laszlo B.; Nevels, Robert D.

    2013-01-01

    We present and analyze a gedanken experiment and show that the assumption that an antenna operating at a single frequency can transmit more than two independent information channels to the far field violates the Second Law of Thermodynamics. Transmission of a large number of channels, each associated with an angular momenta ‘twisted wave’ mode, to the far field in free space is therefore not possible. PMID:23424647

  5. Strong spectral variation of biomass smoke light absorption and single scattering albedo observed with a novel dual-wavelength photoacoustic instrument

    Treesearch

    Kristin Lewis; William P. Arnott; Hans Moosmuller; Cyle E. Wold

    2008-01-01

    A dual-wavelength photoacoustic instrument operating at 405 and 870 nm was used during the 2006 Fire Lab at Missoula Experiment to measure light scattering and absorption by smoke from the combustion of a variety of biomass fuels. Simultaneous measurements of aerosol light scattering by reciprocal nephelometry within the instrument's acoustic resonator accompany...

  6. The effects of display and autopilot functions on pilot workload for Single Pilot Instrument Flight Rule (SPIFR) operations

    NASA Technical Reports Server (NTRS)

    Hoh, Roger H.; Smith, James C.; Hinton, David A.

    1987-01-01

    An analytical and experimental research program was conducted to develop criteria for pilot interaction with advanced controls and displays in single pilot instrument flight rules (SPIFR) operations. The analytic phase reviewed fundamental considerations for pilot workload taking into account existing data, and using that data to develop a divided attention SPIFR pilot workload model. The pilot model was utilized to interpret the two experimental phases. The first experimental phase was a flight test program that evaluated pilot workload in the presence of current and near-term displays and autopilot functions. The second experiment was conducted on a King Air simulator, investigating the effects of co-pilot functions in the presence of very high SPIFR workload. The results indicate that the simplest displays tested were marginal for SPIFR operations. A moving map display aided the most in mental orientation, but had inherent deficiencies as a stand alone replacement for an HSI. Autopilot functions were highly effective for reducing pilot workload. The simulator tests showed that extremely high workload situations can be adequately handled when co-pilot functions are provided.

  7. Design, operation, and safety of single-room interventional MRI suites: practical experience from two centers.

    PubMed

    White, Mark J; Thornton, John S; Hawkes, David J; Hill, Derek L G; Kitchen, Neil; Mancini, Laura; McEvoy, Andrew W; Razavi, Reza; Wilson, Sally; Yousry, Tarek; Keevil, Stephen F

    2015-01-01

    The design and operation of a facility in which a magnetic resonance imaging (MRI) scanner is incorporated into a room used for surgical or endovascular cardiac interventions presents several challenges. MR safety must be maintained in the presence of a much wider variety of equipment than is found in a diagnostic unit, and of staff unfamiliar with the MRI environment, without compromising the safety and practicality of the interventional procedure. Both the MR-guided cardiac interventional unit at Kings College London and the intraoperative imaging suite at the National Hospital for Neurology and Neurosurgery are single-room interventional facilities incorporating 1.5 T cylindrical-bore MRI scanners. The two units employ similar strategies to maintain MR safety, both in original design and day-to-day operational workflows, and between them over a decade of incident-free practice has been accumulated. This article outlines these strategies, highlighting both similarities and differences between the units, as well as some lessons learned and resulting procedural changes made in both units since installation. © 2014 Wiley Periodicals, Inc.

  8. Lung transplantation in patients with pulmonary emphysema.

    PubMed

    Paik, Hyo Chae; Hwang, Jung Joo; Lee, Doo Yun

    2004-12-31

    Lung transplantation is a viable option for patients with chronic obstructive pulmonary disease (COPD), and emphysema is the most common indication to undergo lung transplantation. A total of seven lung and one heart-lung transplantations were performed between July 1996 and June 2004 at the Yongdong Severance Hospital, and herein, three emphysema patients who underwent single lung transplantations are reviewed. There were 2 males and 1 female, with a mean age of 50 years (35, 57 and 58 years). They all underwent an operation, without cardiopulmonary bypass, and there was no operative mortality. The mean survival was 12 months (4 months, 15 months and 17 months) and all succumbed to death due to activation of pulmonary tuberculosis, post-transplantation lymphoproliferative disease and cytomegalovirus (CMV) gastritis associated with asphyxia. Infection was the most common postoperative complication, resulting in longer hospital stays, higher medical expenses and shorter survival rates, necessitating aggressive prophylactic management. The accumulation of experience, modifications to operative procedures and perioperative care may lead to improved early and long-term survival in patients with emphysema undergoing single or bilateral lung transplantations.

  9. Study on a Single-Stage 120 HZ Pulse Tube Cryocooler

    NASA Astrophysics Data System (ADS)

    Wu, Y. Z.; Gan, Z. H.; Qiu, L. M.; Chen, J.; Li, Z. P.

    2010-04-01

    Miniaturization of pulse tube cryocoolers is required for some particular applications where size and mass for devices are limited. In order to pack more cooling power in a small volume, higher operating frequencies are commonly used for Stirling-type pulse tube cryocoolers. To maintain high efficiency of the regenerator with a higher frequency, a higher charging pressure, smaller hydraulic diameters of regenerator material and a shorter regenerator length should be applied. A rapid growth of research and development on pulse tube cryocoolers operating at a high frequency over 100 Hz in the last 3 years has occurred. In this study, a single stage pulse tube cryocooler with 120 Hz to provide 10 W of lift at 80 K has been developed by using the numerical model, known as REGEN 3.2. Experiments performed on this cryocooler driven by a CFIC linear compressor show that a no-load temperature of 49.6 K was achieved and the net refrigeration power at 78.5 K was 8.0 W. The effect of pulse tube orientation was tested, and the copper velvet as a regenerator matrix was proposed for high frequency operation.

  10. Generation of multiple analog pulses with different duty cycles within VME control system for ICRH Aditya system

    NASA Astrophysics Data System (ADS)

    Joshi, Ramesh; Singh, Manoj; Jadav, H. M.; Misra, Kishor; Kulkarni, S. V.; ICRH-RF Group

    2010-02-01

    Ion Cyclotron Resonance Heating (ICRH) is a promising heating method for a fusion device due to its localized power deposition profile, a direct ion heating at high density, and established technology for high RF power generation and transmission at low cost. Multiple analog pulse with different duty cycle in master of digital pulse for Data acquisition and Control system for steady state RF ICRH System(RF ICRH DAC) to be used for operating of RF Generator in Aditya to produce pre ionization and second analog pulse will produce heating. The control system software is based upon single digital pulse operation for RF source. It is planned to integrate multiple analog pulses with different duty cycle in master of digital pulse for Data acquisition and Control system for RF ICRH System(RF ICRH DAC) to be used for operating of RF Generator in Aditya tokamak. The task of RF ICRH DAC is to control and acquisition of all ICRH system operation with all control loop and acquisition for post analysis of data with java based tool. For pre ionization startup as well as heating experiments using multiple RF Power of different powers and duration. The experiment based upon the idea of using single RF generator to energize antenna inside the tokamak to radiate power twise, out of which first analog pulse will produce pre ionization and second analog pulse will produce heating. The whole system is based on standard client server technology using tcp/ip protocol. DAC Software is based on linux operating system for highly reliable, secure and stable system operation in failsafe manner. Client system is based on tcl/tk like toolkit for user interface with c/c++ like environment which is reliable programming languages widely used on stand alone system operation with server as vxWorks real time operating system like environment. The paper is focused on the Data acquisition and monitoring system software on Aditya RF ICRH System with analog pulses in slave mode with digital pulse in master mode for control acquisition and monitoring and interlocking.

  11. The PIX-2 experiment: An overview

    NASA Astrophysics Data System (ADS)

    Purvis, C. K.

    1985-03-01

    The second Plasma Interactions Experiment (PIX-2) was launched in January 1983 as a piggyback on the second stage of the Delta launch vehicle that carried IRAS into orbit. Placed in a 870 km circular polar orbit, it returned 18 hrs of data on the plasma current collection and arcing behavior of solar arrays biased to +/-1000 V in steps. The four 500 sq cm solar array segments were biased singly and in combinations. In addition to the array segments PIX-2 carried a Sun sensor, a Langmuir probe to measure electron currents, and a hot-wire filament electron emitter to control vehicle potential during positive array bias sequences. The PIX-2 experiment is reviewed from program and operational perspectives.

  12. Nonintubated thoracoscopic lung resection: a 3-year experience with 285 cases in a single institution

    PubMed Central

    Chen, Ke-Cheng; Cheng, Ya-Jung; Hung, Ming-Hui; Tseng, Yu-Ding

    2012-01-01

    Objective Tracheal intubation with one-lung ventilation is considered mandatory for thoracoscopic surgery. This study reported the experience of thoracoscopic lung resection without endotracheal intubation in a single institution. Methods From August 2009 through July 2012, 285 consecutive patients were treated by nonintubated thoracoscopic surgery using epidural anesthesia, intrathoracic vagal blockade, and sedation for lobectomy, segmentectomy, or wedge resection in a tertiary medical center. The feasibility and safety of this technique were evaluated. Results The final diagnosis for surgery were primary lung cancer in 159 patients (55.8%), metastatic lung cancer in 17 (6.0%), benign lung tumor in 104 (36.5%), and pneumothorax in 5 (1.8%). The operative methods consisted of conventional (83.2%) and needlescopic (16.8%) thoracoscopic surgery. The operative procedures included lobectomy in 137 patients (48.1%), wedge resection in 132 (46.3%), and segmentectomy in 16 (5.6%). Collapse of the operative lung and inhibition of coughing were satisfactory in most of the patients. Fourteen (4.9%) patients required conversion to tracheal intubation because of significant mediastinal movement [5], persistent hypoxemia [2], dense pleural adhesions [2], ineffective epidural anesthesia [2], bleeding [2], and tachypnea [1]. One patient (0.4%) was converted to thoracotomy because of bleeding. No mortality was noted in our patients. Conclusions Nonintubated thoracoscopic lung resection is technically feasible and safe in selected patients. It can be a valid alternative in managing patients with pulmonary lesions. PMID:22934136

  13. A long-pulse repetitive operation magnetically insulated transmission line oscillator.

    PubMed

    Fan, Yu-Wei; Zhong, Hui-Huang; Zhang, Jian-De; Shu, Ting; Liu, Jin Liang

    2014-05-01

    The improved magnetically insulated transmission line oscillator (MILO) is a gigawatt-class L-band high power microwave tube. It has allowed us to generate 3.1 GW pulse of 40 ns duration in the single-pulse operation and 500 MW pulse of 25 ns duration in the repetition rate operation. However, because of the severe impedance mismatch, the power conversion efficiency is only about 4% in the repetition rate operation. In order to eliminate the impedance mismatch and obtain repetitive long-pulse high-power microwave (HPM), a series of experiments are carried out and the recent progress is presented in this paper. In the single-pulse operation, when the diode voltage is 466 kV and current is 41.6 kA, the radiated microwave power is above 2.2 GW, the pulse duration is above 102 ns, the microwave frequency is about 1.74 GHz, and the power conversion efficiency is about 11.5%. In the repetition rate operation, under the condition of the diode voltage about 400 kV, beam current about 38 kA, the radiated microwave power is about 1.0 GW, the pulse duration is about 85 ns. Moreover, the radiated microwave power and the pulse duration decline little by little when the shot numbers increase gradually. The experimental results show that the impedance matching is a vital factor for HPM systems and one of the major technical challenges is to improve the cathode for the repetition rate operation MILO.

  14. Multiple delivery cesium oven system for negative ion sources

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bansal, G.; Bhartiya, S.; Pandya, K.

    2012-02-15

    Distribution of cesium in large negative ion beam sources to be operational in ITER, is presently based on the use of three or more cesium ovens, which operate simultaneously and are controlled remotely. However, use of multiple Cs ovens simultaneously is likely to pose difficulties in operation and maintenance of the ovens. An alternate method of Cs delivery, based on a single oven distribution system is proposed as one which could reduce the need of simultaneous operation of many ovens. A proof of principle experiment verifying the concept of a multinozzle distributor based Cs oven has been carried out atmore » Institute for Plasma Research. It is also observed that the Cs flux is not controlled by Cs reservoir temperature after few hours of operation but by the temperature of the distributor which starts behaving as a Cs reservoir.« less

  15. Robotic single port cholecystectomy (R-LESS-C): experience in 36 patients.

    PubMed

    Uras, Cihan; Böler, Deniz Eren; Ergüner, Ilknur; Hamzaoğlu, Ismail

    2014-07-01

    Laparoendoscopic single-site surgery (LESS) has emerged as a result of a search for "pain-less" and "scar-less" surgery. Laparoendoscopic single-site cholecystectomy (LESS-C) is probably the most common application in general surgery, although it harbors certain limitations. It was proposed that the da Vinci Single-Site (Si) robotic system may overcome some of the difficulties experienced during LESS, providing three dimensional views and the ability to work in a right-handed fashion. Thirty-six robotic single port cholecystectomies (R-LESS-C) performed with the da Vinci Si robotic system are evaluated in this paper R-LESS-C performed in 36 patients were reviewed. The data related to the perioperative period (i.e., anesthesia time, operation time, docking time, and console time) was recorded prospectively, whereas the hospitalization period, postoperative visual analogue scale (VAS) pain scores were collected retrospectively. A total number of 36 patients, with a mean age of 40.1 years (21-64 years), underwent R-LESS-C. There were five men and 31 women. The mean anesthesia and operation times were 79.3 minutes (45-130 minutes) and 61.8 minutes (34-110 minutes), respectively. The mean docking time was 9.8 minutes (4-30 minutes) and the mean console time was 24.9 minutes (7-60 minutes). The mean hospital stay was 1.05 days (1-2 days) and the mean pain score (VAS) was 3.6 (2-8) in the first 24 hours. Incisional hernia was recorded in one patient. R-LESS-C can be performed reliably with acceptable operative times and safety. The da Vinci Si robotic system may ease LESS-C. Two issues should be considered for routine use: expensive resources are needed and the incidence of incisional hernia may increase. Copyright © 2013. Published by Elsevier B.V.

  16. Evaluation of commercial ADC radiation tolerance for accelerator experiments

    DOE PAGES

    Chen, K.; Chen, H.; Kierstead, J.; ...

    2015-08-17

    Electronic components used in high energy physics experiments are subjected to a radiation background composed of high energy hadrons, mesons and photons. These particles can induce permanent and transient effects that affect the normal device operation. Ionizing dose and displacement damage can cause chronic damage which disable the device permanently. Transient effects or single event effects are in general recoverable with time intervals that depend on the nature of the failure. The magnitude of these effects is technology dependent with feature size being one of the key parameters. Analog to digital converters are components that are frequently used in detectormore » front end electronics, generally placed as close as possible to the sensing elements to maximize signal fidelity. We report on radiation effects tests conducted on 17 commercially available analog to digital converters and extensive single event effect measurements on specific twelve and fourteen bit ADCs that presented high tolerance to ionizing dose. We discuss mitigation strategies for single event effects (SEE) for their use in the large hadron collider environment.« less

  17. Post-inscription tuning of multicore fiber Bragg gratings

    NASA Astrophysics Data System (ADS)

    Lindley, Emma Y.; Min, Seong-sik; Leon-Saval, Sergio G.; Bland-Hawthorn, Joss

    2016-07-01

    Fiber Bragg gratings are used in astronomy for their ability to suppress narrow atmospheric emission lines of temporally varying brightness before the light is dispersed. These gratings can only operate in a single-mode fiber as the suppressed wavelength depends on mode velocity in the core. Recent experiments with fibers containing multiple single-moded cores have demonstrated the potential for inscribing identical gratings across all cores in a single pass. We have already improved the uniformity of gratings in 7-core fibers via modifications to the writing process; further progress can be achieved by tuning the gratings of the outer and inner cores relative to one another. Our eventual goal is to make the entire fiber suppress one wavelength to a depth of 30 dB or greater. By coating the fiber in a heat-conductive material with a high expansion coefficient, we can examine the effects of temperature and strain on the spectral response of each core. In this paper we present methods and results from experiments concerning the post-write tuning of gratings in multicore fibers.

  18. Efficient monitoring of CRAB jobs at CMS

    NASA Astrophysics Data System (ADS)

    Silva, J. M. D.; Balcas, J.; Belforte, S.; Ciangottini, D.; Mascheroni, M.; Rupeika, E. A.; Ivanov, T. T.; Hernandez, J. M.; Vaandering, E.

    2017-10-01

    CRAB is a tool used for distributed analysis of CMS data. Users can submit sets of jobs with similar requirements (tasks) with a single request. CRAB uses a client-server architecture, where a lightweight client, a server, and ancillary services work together and are maintained by CMS operators at CERN. As with most complex software, good monitoring tools are crucial for efficient use and longterm maintainability. This work gives an overview of the monitoring tools developed to ensure the CRAB server and infrastructure are functional, help operators debug user problems, and minimize overhead and operating cost. This work also illustrates the design choices and gives a report on our experience with the tools we developed and the external ones we used.

  19. Efficient Monitoring of CRAB Jobs at CMS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Silva, J. M.D.; Balcas, J.; Belforte, S.

    CRAB is a tool used for distributed analysis of CMS data. Users can submit sets of jobs with similar requirements (tasks) with a single request. CRAB uses a client-server architecture, where a lightweight client, a server, and ancillary services work together and are maintained by CMS operators at CERN. As with most complex software, good monitoring tools are crucial for efficient use and longterm maintainability. This work gives an overview of the monitoring tools developed to ensure the CRAB server and infrastructure are functional, help operators debug user problems, and minimize overhead and operating cost. This work also illustrates themore » design choices and gives a report on our experience with the tools we developed and the external ones we used.« less

  20. Glovebox and Experiment Safety

    NASA Astrophysics Data System (ADS)

    Maas, Gerard

    2005-12-01

    Human spaceflight hardware and operations must comply with NSTS 1700.7. This paper discusses how a glovebox can help.A short layout is given on the process according NSTS/ISS 13830, explaining the responsibility of the payload organization, the approval authority of the PSRP and the defined review phases (0 till III).Amongst others, the following requirement has to be met:"200.1 Design to Tolerate Failures. Failure tolerance is the basic safety requirement that shall be used to control most payload hazards. The payload must tolerate a minimum number of credible failures and/or operator errors determined by the hazard level. This criterion applies when the loss of a function or the inadvertent occurrence of a function results in a hazardous event.200.1a Critical Hazards. Critical hazards shall be controlled such that no single failure or operator error can result in damage to STS/ISS equipment, a nondisabling personnel injury, or the use of unscheduled safing procedures that affect operations of the Orbiter/ISS or another payload.200.1b Catastrophic Hazards. Catastrophic hazards shall be controlled such that no combination of two failures or operator errors can result in the potential for a disabling or fatal personnel injury or loss of the Orbiter/ISS, ground facilities or STS/ISS equipment."For experiments in material science, biological science and life science that require real time operator manipulation, the above requirement may be hard or impossible to meet. Especially if the experiment contains substances that are considered hazardous when released into the habitable environment. In this case operation of the experiment in a glovebox can help to comply.A glovebox provides containment of the experiment and at the same time allows manipulation and visibility to the experiment.The containment inside the glovebox provides failure tolerance because the glovebox uses a negative pressure inside the working volume (WV). The level of failure tolerance is dependent of: the identified failure case and the hazardous substance being released (chemical, biological or different).The principle of the glovebox operation is explained, including: mechanical enclosure, air circulation, air filtration and operational modes.Limitations of the glovebox are presented: inability of an experiment fire to be detected by the ASDA, containment only with respect to specified substances, etc. There are requirements induced by the glovebox that the experiment must comply with: Compatibility with the glovebox filter system, thermal limitations, safe without glovebox services, parameter monitoring when a fire hazard is credible, sufficient containment when entering the glovebox and after the experiment, etc.Experiments that are using a glovebox to be operated in shall assess this integrated set-up and the associated operations for compliance to the safety requirements. During this assessment the PSRP shall determine if the provided failure tolerance is sufficient.The gloveboxes that Bradford Engineering (co-) built for human space flight are: USML-1 and 2, MGBX (STS and MIR), MSG, PGBX, LSG-WVA, BGB and PGB. Some of the evolutions are pointed out (experiment services added without compromising safety levels). The major differences of the gloveboxes are presented. For the gloveboxes that are in operation at this time (MSG) or in the near future (BGB, LSG- WVA and PGB) the specific applications are presented.

  1. Deterministic Multi-hop Controlled Teleportation of Arbitrary Single-Qubit State

    NASA Astrophysics Data System (ADS)

    Peng, Jia-yin; Bai, Ming-qiang; Mo, Zhi-wen

    2017-10-01

    Multi-hop teleportation is of great significance due to long-distance delivery of quantum information and wireless quantum communication networks. In existing protocols of multi-hop teleportation, the more nodes, the smaller the success probability. In this paper, fusing the ideas of multi-hop teleportation and controlled teleportation, we put forward a scheme for implementing multi-hop controlled teleportation of single-qubit state. A set of ingenious three-qubit non-maximally entangled states are constructed to serve as the quantum channels. The information is perfectly transmitted hop by hop through teleportation under the control of the supervisors. Unit success probability can be achieved independent of channel's entanglement degree and the number of intermediate nodes. Only Pauli operations, single-qubit rotation, Hadamard gate, controlled-NOT gate, Bell-state measurement and single-qubit measurement are used in our scheme, so this scheme is easily realized in physical experiment.

  2. Optical proposals for controlled delayed-choice experiment based on weak cross-Kerr nonlinearities

    NASA Astrophysics Data System (ADS)

    Dong, Li; Lin, Yan-Fang; Li, Qing-Yang; Xiu, Xiao-Ming; Dong, Hai-Kuan; Gao, Ya-Jun

    2017-05-01

    Employing polarization modes of a photon, we propose two theoretical proposals to exhibit the wave-particle duality of the photon with the assistance of weak cross-Kerr nonlinearities. The first proposal is a classical controlled delayed-choice experiment (that is, Wheeler's delayed-choice experiment), where we can observe selectively wave property or particle property of the photon relying on the experimenter's selection, whereas the second proposal is a quantum controlled delayed-choice experiment, by which the mixture phenomenon of a wave and a particle will be exhibited. Both of them can be realized with near-unity probability and embody the charming characteristics of quantum mechanics. The employment of the mature techniques and simple operations (e.g., Homodyne measurement, classical feed forward, and single-photon transformations) provides the feasibility of the delayed-choice experiment proposals presented here.

  3. A transition to laparoendoscopic single-site surgery (LESS) radical prostatectomy: human cadaver experimental and initial clinical experience.

    PubMed

    Barret, Eric; Sanchez-Salas, Rafael; Kasraeian, Ali; Benoist, Nicolas; Ganatra, Anjali; Cathelineau, Xavier; Rozet, Francois; Galiano, Marc; Vallancien, Guy

    2009-01-01

    Laparoendoscopic single-site surgery (LESS) represents a novel approach to abdominal surgery. Several applications have already been described. Drawbacks include limited range of motion and need for articulated instruments. Robotic technology could overcome such technical difficulties. We report our experience with LESS radical prostatectomy (LESS-RP) in a cadaver and LESS robot-assisted radical prostatectomy (LESS-RARP) in a human patient. Standard laparoscopic instruments (SLI) and articulated laparoscopic instruments were used in the cadaveric LESS-RP. The da Vinci system was used in the LESS-RARP. Both procedures reproduced standard extraperitoneal laparoscopic prostatectomy as performed at Institut Montsouris. Control of the dorsal venous complex (DVC) and urethrovesical anastomosis (UVA) were key elements evaluated for feasibility. Cadaveric model: Total operative time (TOT) was 160 minutes, with 5 minutes for the DVC (one stitch) and 35 minutes for the UVA (six stitches). Although articulated instruments were helpful in the operation, SLI remained essential for the procedure. Clinical experience: LESS-RARP was performed for T(1c) prostate cancer. TOT was 150 minutes, including 5 minutes for the DVC (one figure-of-eight stitch) and 30 minutes for the UVA (six interrupted stitches). Blood loss was 500 mL. Bilateral neurovascular preservation was performed, and results of final pathologic examination showed negative surgical margins. The human cadaver is an adequate model for LESS-RP, and LESS-RARP is feasible to be performed in the clinical arena. The synergy of robotic technology and LESS represents a new generation of surgery.

  4. Invited Article: Coherent imaging using seeded free-electron laser pulses with variable polarization: First results and research opportunities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Capotondi, F.; Pedersoli, E.; Mahne, N.

    2013-05-15

    FERMI-Elettra, the first vacuum ultraviolet and soft X-ray free-electron laser (FEL) using by default a 'seeded' scheme, became operational in 2011 and has been opened to users since December 2012. The parameters of the seeded FERMI FEL pulses and, in particular, the superior control of emitted radiation in terms of spectral purity and stability meet the stringent requirements for single-shot and resonant coherent diffraction imaging (CDI) experiments. The advantages of the intense seeded FERMI pulses with variable polarization have been demonstrated with the first experiments performed using the multipurpose experimental station operated at the diffraction and projection imaging (DiProI) beamline.more » The results reported here were obtained with fixed non-periodic targets during the commissioning period in 2012 using 20-32 nm wavelength range. They demonstrate that the performance of the FERMI FEL source and the experimental station meets the requirements of CDI, holography, and resonant magnetic scattering in both multi- and single-shot modes. Moreover, we present the first magnetic scattering experiments employing the fully circularly polarized FERMI pulses. The ongoing developments aim at pushing the lateral resolution by using shorter wavelengths provided by double-stage cascaded FERMI FEL-2 and probing ultrafast dynamic processes using different pump-probe schemes, including jitter-free seed laser pump or FEL-pump/FEL-probe with two color FEL pulses generated by the same electron bunch.« less

  5. Parity-time–symmetric optoelectronic oscillator

    PubMed Central

    2018-01-01

    An optoelectronic oscillator (OEO) is a hybrid microwave and photonic system incorporating an amplified positive feedback loop to enable microwave oscillation to generate a high-frequency and low–phase noise microwave signal. The low phase noise is ensured by the high Q factor of the feedback loop enabled by the use of a long and low-loss optical fiber. However, an OEO with a long fiber loop would have a small free spectral range, leading to a large number of closely spaced oscillation modes. To ensure single-mode oscillation, an ultranarrowband optical filter must be used, but such an optical filter is hard to implement and the stability is poor. Here, we use a novel concept to achieve single-mode oscillation without using an ultranarrowband optical filter. The single-mode operation is achieved based on parity-time (PT) symmetry by using two identical feedback loops, with one having a gain and the other having a loss of the same magnitude. The operation is analyzed theoretically and verified by an experiment. Stable single-mode oscillation at an ultralow phase noise is achieved without the use of an ultranarrowband optical filter. The use of PT symmetry in an OEO overcomes the long-existing mode-selection challenge that would greatly simplify the implementation of OEOs for ultralow–phase noise microwave generation. PMID:29888325

  6. [Experimental study on single-electrode metal detector for taking off foreign bodies from the swine].

    PubMed

    Wang, Li-Gang; Zhang, Gen-Min

    2010-06-01

    To study the practicability of single-electrode metal detector by using it to take off foreign bodies from swine. The single-electrode metal detector was invented based on the theory of complementary oscillator. Twelve extremities were obtained from 3 Minnesota-Hormel stains 7-month old male swine. All the extremities were divided into 3 groups: lump metal foreign bodies were planted in group A, needle shape metal foreign bodies were planted in group B, and sand shapd metal foreign bodies were planted in group C. The self-invented single-electrode metal detector was used to take off these foreign bodies, and the taking times were recorded. After the operation, the X-ray was used to examine if the foreign bodies were still in the extremities of the swine. The foreign bodies were taken off completely in the 3 groups, and the average time were 38 s, 3 min and 12 s, and 3 min and 59 s respectively. The X-ray examination confirmed that the detector could take off the foreign bodies completely. This detector has satisfactory effect in animal experiment, which could detect and extract metal foreign bodies quickly and exactly without X-ray help duration the operation, and can be used in clinical cases secondly.

  7. “Ipsilateral, high, single-hand, sideways”—Ruijin rule for camera assistant in uniportal video-assisted thoracoscopic surgery

    PubMed Central

    Gao, Taotao; Xiang, Jie; Jin, Runsen; Zhang, Yajie; Wu, Han

    2016-01-01

    Camera assistant plays a very important role in uniportal video-assisted thoracoscopic surgery (VATS), who acts as the eye of the surgeon, providing the VATS team with a stable and clear operating view. Thus, a good assistant should cooperate with surgeon and manipulate the camera expertly, to ensure eye-hand coordination. We have performed more than 100 uniportal VATS in the Department Of Thoracic Surgery in Ruijin Hospital. Based on our experiences, we summarized the method of holding camera, known as “ipsilateral, high, single-hand, sideways”, which largely improves the comfort and fluency of surgery. PMID:27867573

  8. MUSIC-type imaging of a thin penetrable inclusion from its multi-static response matrix

    NASA Astrophysics Data System (ADS)

    Park, Won-Kwang; Lesselier, Dominique

    2009-07-01

    The imaging of a thin inclusion, with dielectric and/or magnetic contrasts with respect to the embedding homogeneous medium, is investigated. A MUSIC-type algorithm operating at a single time-harmonic frequency is developed in order to map the inclusion (that is, to retrieve its supporting curve) from scattered field data collected within the multi-static response matrix. Numerical experiments carried out for several types of inclusions (dielectric and/or magnetic ones, straight or curved ones), mostly single inclusions and also two of them close by as a straightforward extension, illustrate the pros and cons of the proposed imaging method.

  9. Proceedings of the 20th International Symposium on Space Flight Dynamics

    NASA Technical Reports Server (NTRS)

    Woodard, Mark (Editor); Stengle, Tom (Editor)

    2007-01-01

    Topics include: Measuring Image Navigation and Registration Performance at the 3-Sigma Level Using Platinum Quality Landmarks; Flight Dynamics Performances of the MetOp A Satellite during the First Months of Operations; Visual Navigation - SARE Mission; Determining a Method of Enabling and Disabling the Integral Torque in the SDO Science and Inertial Mode Controllers; Guaranteeing Pointing Performance of the SDO Sun-Pointing Controllers in Light of Nonlinear Effects; SDO Delta H Mode Design and Analysis; Observing Mode Attitude Controller for the Lunar Reconnaissance Orbiter; Broken-Plane Maneuver Applications for Earth to Mars Trajectories; ExoMars Mission Analysis and Design - Launch, Cruise and Arrival Analyses; Mars Reconnaissance Orbiter Aerobraking Daily Operations and Collision Avoidance; Mars Reconnaissance Orbiter Interplanetary Cruise Navigation; Motion Parameters Determination of the SC and Phobos in the Project Phobos-Grunt; GRAS NRT Precise Orbit Determination: Operational Experience; Orbit Determination of LEO Satellites for a Single Pass through a Radar: Comparison of Methods; Orbit Determination System for Low Earth Orbit Satellites; Precise Orbit Determination for ALOS; Anti-Collision Function Design and Performances of the CNES Formation Flying Experiment on the PRISMA Mission; CNES Approaching Guidance Experiment within FFIORD; Maneuver Recovery Analysis for the Magnetospheric Multiscale Mission; SIMBOL-X: A Formation Flying Mission on HEO for Exploring the Universe; Spaceborne Autonomous and Ground Based Relative Orbit Control for the TerraSAR-X/TanDEM-X Formation; First In-Orbit Experience of TerraSAR-X Flight Dynamics Operations; Automated Target Planning for FUSE Using the SOVA Algorithm; Space Technology 5 Post-Launch Ground Attitude Estimation Experience; Standardizing Navigation Data: A Status Update; and A Study into the Method of Precise Orbit Determination of a HEO Orbiter by GPS and Accelerometer.

  10. Instrumental requirements for the detection of electron beam-induced object excitations at the single atom level in high-resolution transmission electron microscopy.

    PubMed

    Kisielowski, C; Specht, P; Gygax, S M; Barton, B; Calderon, H A; Kang, J H; Cieslinski, R

    2015-01-01

    This contribution touches on essential requirements for instrument stability and resolution that allows operating advanced electron microscopes at the edge to technological capabilities. They enable the detection of single atoms and their dynamic behavior on a length scale of picometers in real time. It is understood that the observed atom dynamic is intimately linked to the relaxation and thermalization of electron beam-induced sample excitation. Resulting contrast fluctuations are beam current dependent and largely contribute to a contrast mismatch between experiments and theory if not considered. If explored, they open the possibility to study functional behavior of nanocrystals and single molecules at the atomic level in real time. Copyright © 2014 Elsevier Ltd. All rights reserved.

  11. An Improved Azimuth Angle Estimation Method with a Single Acoustic Vector Sensor Based on an Active Sonar Detection System

    PubMed Central

    Zhao, Anbang; Ma, Lin; Ma, Xuefei; Hui, Juan

    2017-01-01

    In this paper, an improved azimuth angle estimation method with a single acoustic vector sensor (AVS) is proposed based on matched filtering theory. The proposed method is mainly applied in an active sonar detection system. According to the conventional passive method based on complex acoustic intensity measurement, the mathematical and physical model of this proposed method is described in detail. The computer simulation and lake experiments results indicate that this method can realize the azimuth angle estimation with high precision by using only a single AVS. Compared with the conventional method, the proposed method achieves better estimation performance. Moreover, the proposed method does not require complex operations in frequency-domain and achieves computational complexity reduction. PMID:28230763

  12. Current at Metal-Organic Interfaces

    NASA Astrophysics Data System (ADS)

    Kern, Klaus

    2012-02-01

    Charge transport through atomic and molecular constrictions greatly affects the operation and performance of organic electronic devices. Much of our understanding of the charge injection and extraction processes in these systems relays on our knowledge of the electronic structure at the metal-organic interface. Despite significant experimental and theoretical advances in studying charge transport in nanoscale junctions, a microscopic understanding at the single atom/molecule level is missing. In the present talk I will present our recent results to probe directly the nanocontact between single molecules and a metal electrode using scanning probe microscopy and spectroscopy. The experiments provide unprecedented microscopic details of single molecule and atom junctions and open new avenues to study quantum critical and many body phenomena at the atomic scale. Implications for energy conversion devices and carbon based nanoelectronics will also be discussed.

  13. Cholecystectomy using a novel Single-Site(®) robotic platform: early experience from 45 consecutive cases.

    PubMed

    Konstantinidis, Konstantinos M; Hirides, Petros; Hirides, Savas; Chrysocheris, Pericles; Georgiou, Michael

    2012-09-01

    The aim of this work was to study the feasibility, safety, and efficacy of single-incision robotic cholecystectomy using a novel platform from Intuitive Surgical. All operations were performed by the same surgeon. Parameters assessed included patient history, indication for surgery, operation time, complication rate, conversion rate, robot-related issues, length of hospital stay, postoperative pain, and time to return to work. All patients were followed for a 2-month period postoperatively. Forty-five patients (22 women, 23 men) underwent single-incision robotic cholecystectomy from March 1 to July 15, 2011. There were no conversions to either conventional laparoscopy or laparotomy, although in three cases a second trocar was used. There were no major complications apart from a single case of postoperative hemorrhage. Average patient age was 47 ± 12 years (range = 27-80 years) and average BMI was 30 kg/m(2) (mean = 28.8 ± 4 kg/m(2), range = 18.4-46.7 kg/m(2)). The primary indication for surgery was gallstones. The mean operation time (skin-to-skin) was 84.5 ± 25.5 min (range = 51-175 min), docking time was 5.8 ± 1.5 min (range = 4-11 min), and console time (net surgical time) was 43 ± 21.9 min (range = 21-121 min). Intraoperative blood loss was negligible. There were no collisions between the robotic arms and no other robot-related problems. Average postoperative length of stay was less than 24 h. The mean Visual Analog Pain Scale Score 6 h after the operation was 2.2 ± 1.51 (range = 0-6) and patients returned to normal activities in 4.48 ± 2.3 days (range = 1-9 days). Single-Site(®) is a new platform offering a potentially more stable and reliable environment to perform single-port cholecystectomy. Both simple and complicated cholecystectomies can be performed with safety. The technique is possible in patients with a high BMI. The induction of pneumoperitoneum using the new port and the docking process require additional training.

  14. Ephus: Multipurpose Data Acquisition Software for Neuroscience Experiments

    PubMed Central

    Suter, Benjamin A.; O'Connor, Timothy; Iyer, Vijay; Petreanu, Leopoldo T.; Hooks, Bryan M.; Kiritani, Taro; Svoboda, Karel; Shepherd, Gordon M. G.

    2010-01-01

    Physiological measurements in neuroscience experiments often involve complex stimulus paradigms and multiple data channels. Ephus (http://www.ephus.org) is an open-source software package designed for general-purpose data acquisition and instrument control. Ephus operates as a collection of modular programs, including an ephys program for standard whole-cell recording with single or multiple electrodes in typical electrophysiological experiments, and a mapper program for synaptic circuit mapping experiments involving laser scanning photostimulation based on glutamate uncaging or channelrhodopsin-2 excitation. Custom user functions allow user-extensibility at multiple levels, including on-line analysis and closed-loop experiments, where experimental parameters can be changed based on recently acquired data, such as during in vivo behavioral experiments. Ephus is compatible with a variety of data acquisition and imaging hardware. This paper describes the main features and modules of Ephus and their use in representative experimental applications. PMID:21960959

  15. Fully automated multifunctional ultrahigh pressure liquid chromatography system for advanced proteome analyses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, Jung Hwa; Hyung, Seok-Won; Mun, Dong-Gi

    2012-08-03

    A multi-functional liquid chromatography system that performs 1-dimensional, 2-dimensional (strong cation exchange/reverse phase liquid chromatography, or SCX/RPLC) separations, and online phosphopeptides enrichment using a single binary nano-flow pump has been developed. With a simple operation of a function selection valve, which is equipped with a SCX column and a TiO2 (titanium dioxide) column, a fully automated selection of three different experiment modes was achieved. Because the current system uses essentially the same solvent flow paths, the same trap column, and the same separation column for reverse-phase separation of 1D, 2D, and online phosphopeptides enrichment experiments, the elution time information obtainedmore » from these experiments is in excellent agreement, which facilitates correlating peptide information from different experiments.« less

  16. Medical student experience in surgery influences their career choices: a systematic review of the literature.

    PubMed

    Marshall, Dominic C; Salciccioli, Justin D; Walton, Sarah-Jane; Pitkin, Joan; Shalhoub, Joseph; Malietzis, George

    2015-01-01

    Student experiences during surgical rotations may dictate interest in future surgical careers. The objective of this study was to systematically examine the effect of surgical experience (SE) on student attitudes toward surgical careers and also to identify variables influencing the educational value of SE. A systematic review of the available literature was conducted by 2 independent researchers searching Medline, EMBASE, Google Scholar, and Cochrane databases, in accordance with the Preferred Reporting Items for Systematic Review and Meta-Analyses recommendations. Studies assessing SE during the students' surgical rotations were identified. The quality of the included studies was assessed using a validated quality index. Factors affecting student surgical rotation experience and perceptions of surgical careers were recorded. Overall, 204 studies were identified; 20 unique studies met the inclusion criteria with a median cohort size of 169 (interquartile range: 107-262) respondents. Most were cross-sectional surveys (n = 16/20) and administered to clinical students (n = 16/20). All studies investigating the effect of SE on career choices (n = 8) found that positive experiences during the surgical placement were associated with an increased interest in surgical careers. The operating theater experience was identified as a defining feature of overall SE. Involvement in operative procedures, a welcoming environment, and avoidance of syncopal events positively influenced the SE, particularly in those who actively sought educational opportunities. Study limitations included single-center and single-year cohort designs (70%) with the use of nonvalidated research tools (95%). A systematic review of the literature highlights a number of factors associated with a positive surgical rotation, which may lead to more students deciding to pursue a career in surgery. Understanding the factors that contribute to these decisions through multicenter studies using validated research tools may lead to more effective surgical rotations, ultimately improving the delivery of the surgical education. Copyright © 2015 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  17. A 40-kW fuel cell field test summary utilities activities report

    NASA Astrophysics Data System (ADS)

    Racine, W. C.; Londos, T. C.

    1987-07-01

    Forty six 40 kW fuel cell power plants were field tested by 37 host participants at 42 sites in a variety of commercial, light industrial and multifamily residential applications. The participants obtained over 300,000 hours of operating experience with the power plants covering a diverse range of applications for power plant electricity and heat utilization in both single and multiple unit installations.

  18. Mod-2 wind turbine system cluster research test program. Volume 1: Initial plan E-1290

    NASA Technical Reports Server (NTRS)

    Gordon, L. H.

    1982-01-01

    Upon completion of the design and development of three Mod-2 wind turbines, a series of research experiments are planned to gather data on and evaluate the performance, environmental effects, and operation of a cluster as well as a single, large multimegawatt wind turbine. Information on the program objectives, a Mod-2 system description, a planned schedule, organizational roles, and responsibilities, is included.

  19. Develop and test fuel cell powered on-site integrated total energy systems. Phase 3: Full-scale power plant development

    NASA Technical Reports Server (NTRS)

    Feigenbaum, H.; Kaufman, A.; Wang, C. L.; Werth, J.; Whelan, J. A.

    1983-01-01

    Operating experience with a 5kW methanol-air integrated system is described. On-going test results for a 24-cell, two-sq ft (4kW) stack are reported. The main activity for this stack is currently the evaluation of developmental non-metalic cooling plates. Single-cell test results are presented for a promising developmental cathode catalyst.

  20. Academic Research Vessels 1985-1990.

    DTIC Science & Technology

    1982-01-01

    converted to a single-point lifting system for launch and recovery (UNOLS submersible report). The experience of the Navy in operatin -’ the SEA CLIFF...on improvements in our technical capabilities. The Ocean Sciences Board has recenitW carried out studies on computer needs and on satellite systems ...tions, not on system -wide savings incurred by redistribution of the fleet). Though there is a reduction of approximately 13 percent in operating costs

  1. An Investigation into the Potential Benefits of Distributed Electric Propulsion on Small UAVs at Low Reynolds Numbers

    NASA Astrophysics Data System (ADS)

    Baris, Engin

    Distributed electric propulsion systems benefit from the inherent scale independence of electric propulsion. This property allows the designer to place multiple small electric motors along the wing of an aircraft instead of using a single or several internal combustion motors with gear boxes or other power train components. Aircraft operating at low Reynolds numbers are ideal candidates for benefiting from increased local flow velocities as provided by distributed propulsion systems. In this study, a distributed electric propulsion system made up of eight motor/propellers was integrated into the leading edge of a small fixed wing-body model to investigate the expected improvements on the aerodynamics available to small UAVs operating at low Reynolds numbers. Wind tunnel tests featuring a Design of Experiments (DOE) methodology were used for aerodynamic characterization. Experiments were performed in four modes: all-propellers-on, wing-tip-propellers-alone-on, wing-alone mode, and two-inboard-propellers-on-alone mode. In addition, the all-propeller-on, wing-alone, and a single-tractor configuration were analyzed using VSPAERO, a vortex lattice code, to make comparisons between these different configurations. Results show that the distributed propulsion system has higher normal force, endurance, and range features, despite a potential weight penalty.

  2. Hardware for dynamic quantum computing experiments: Part I

    NASA Astrophysics Data System (ADS)

    Johnson, Blake; Ryan, Colm; Riste, Diego; Donovan, Brian; Ohki, Thomas

    Static, pre-defined control sequences routinely achieve high-fidelity operation on superconducting quantum processors. Efforts toward dynamic experiments depending on real-time information have mostly proceeded through hardware duplication and triggers, requiring a combinatorial explosion in the number of channels. We provide a hardware efficient solution to dynamic control with a complete platform of specialized FPGA-based control and readout electronics; these components enable arbitrary control flow, low-latency feedback and/or feedforward, and scale far beyond single-qubit control and measurement. We will introduce the BBN Arbitrary Pulse Sequencer 2 (APS2) control system and the X6 QDSP readout platform. The BBN APS2 features: a sequencer built around implementing short quantum gates, a sequence cache to allow long sequences with branching structures, subroutines for code re-use, and a trigger distribution module to capture and distribute steering information. The X6 QDSP features a single-stage DSP pipeline that combines demodulation with arbitrary integration kernels, and multiple taps to inspect data flow for debugging and calibration. We will show system performance when putting it all together, including a latency budget for feedforward operations. This research was funded by the Office of the Director of National Intelligence (ODNI), Intelligence Advanced Research Projects Activity (IARPA), through the Army Research Office Contract No. W911NF-10-1-0324.

  3. Percutaneous nephrostomy for symptomatic hypermobile kidney: a single centre experience.

    PubMed

    Starownik, Radosław; Golabek, Tomasz; Bar, Krzysztof; Muc, Kamil; Płaza, Paweł; Chlosta, Piotr

    2014-12-01

    Symptomatic hypermobile kidney is treated with nephropexy, a surgical procedure through which the floating kidney is fixed to the retroperitoneum. Although both open and endoscopic procedures have a high success rate, they can be associated with risk of complications, relatively long hospital stay and high cost. We describe our percutaneous technique for fixing a hypermobile kidney and evaluate the efficacy of the percutaneous nephrostomy insertion in management of symptomatic nephroptosis. Between January 2005 and December 2011, 11 patients diagnosed with a symptomatic right nephroptosis of at least 1 year duration were treated with a single point percutaneous nephrostomy technique. All data were retrieved from patients' medical records and then retrospectively analysed. Nephropexy through a single point percutaneous nephrostomy technique was successfully accomplished in 11 women. The mean operative time was 20 min. The intraoperative estimated blood loss was minimal in all cases. No major or minor intraoperative complications were noted. The average postoperative hospital stay was 2 days. Women returned to their usual activities 14 days following the surgery. Nine women had complete resolution of their pain, and 2 patients continued to complain of discomfort in their lumbar area. One patient was re-operated upon with satisfactory subjective and objective outcomes achieved. One patient refused re-operation. Percutaneous nephropexy is simple, inexpensive and effective for treatment of symptomatic hypermobile kidney. It remains a valuable alternative to open, laparoscopic, and robotic methods for fixing a floating kidney.

  4. Anisotropic interactions of a single spin and dark-spin spectroscopy in diamond

    NASA Astrophysics Data System (ADS)

    Epstein, R. J.; Mendoza, F. M.; Kato, Y. K.; Awschalom, D. D.

    2005-11-01

    Experiments on single nitrogen-vacancy (N-V) centres in diamond, which include electron spin resonance, Rabi oscillations, single-shot spin readout and two-qubit operations with a nearby13C nuclear spin, show the potential of this spin system for solid-state quantum information processing. Moreover, N-V centre ensembles can have spin-coherence times exceeding 50 μs at room temperature. We have developed an angle-resolved magneto-photoluminescence microscope apparatus to investigate the anisotropic electron-spin interactions of single N-V centres at room temperature. We observe negative peaks in the photoluminescence as a function of both magnetic-field magnitude and angle that are explained by coherent spin precession and anisotropic relaxation at spin-level anti-crossings. In addition, precise field alignment unmasks the resonant coupling to neighbouring `dark' nitrogen spins, otherwise undetected by photoluminescence. These results demonstrate the capability of our spectroscopic technique for measuring small numbers of dark spins by means of a single bright spin under ambient conditions.

  5. Initial experience with robotic pancreatic surgery in Singapore: single institution experience with 30 consecutive cases.

    PubMed

    Goh, Brian K P; Low, Tze-Yi; Lee, Ser-Yee; Chan, Chung-Yip; Chung, Alexander Y F; Ooi, London L P J

    2018-05-24

    Presently, the worldwide experience with robotic pancreatic surgery (RPS) is increasing although widespread adoption remains limited. In this study, we report our initial experience with RPS. This is a retrospective review of a single institution prospective database of 72 consecutive robotic hepatopancreatobiliary surgeries performed between 2013 and 2017. Of these, 30 patients who underwent RPS were included in this study of which 25 were performed by a single surgeon. The most common procedure was robotic distal pancreatectomy (RDP) which was performed in 20 patients. This included eight subtotal pancreatectomies, two extended pancreatecto-splenectomies (en bloc gastric resection) and 10 spleen-saving-RDP. Splenic preservation was successful in 10/11 attempted spleen-saving-RDP. Eight patients underwent pancreaticoduodenectomies (five hybrid with open reconstruction), one patient underwent a modified Puestow procedure and one enucleation of uncinate tumour. Four patients had extended resections including two RDP with gastric resection and two pancreaticoduodenectomies with vascular resection. There was one (3.3%) open conversion and seven (23.3%) major (>Grade II) morbidities. Overall, there were four (13.3%) clinically significant (Grade B) pancreatic fistulas of which three required percutaneous drainage. These occurred after three RDP and one robotic enucleation. There was one reoperation for port-site hernia and no 30-day/in-hospital mortalities. The median post-operative stay was 6.5 (range: 3-36) days and there were six (20%) 30-day readmissions. Our initial experience showed that RPS can be adopted safely with a low open conversion rate for a wide variety of procedures including pancreaticoduodenectomy. © 2018 Royal Australasian College of Surgeons.

  6. Telescience testbed experiments for biomedical studies: fertilization potential recording of amphibian eggs using tele-manipulation under stereoscopic vision.

    PubMed

    Watanabe, S; Tanaka, M; Wada, Y; Suzuki, H; Takagi, S; Mori, S; Fukai, K; Kanazawa, Y; Takagi, M; Hirakawa, K; Ogasawara, K; Tsumura, K; Ogawa, K; Matsumoto, K; Nagaoka, S; Suzuki, T; Shimura, D; Yamashita, M; Nishio, S

    1994-07-01

    The telescience testbed experiments were carried out to test and investigate the tele-manipulation techniques in the intracellular potential recording of amphibian eggs. Implementation of telescience testbed was set up in the two separated laboratories of the Tsukuba Space center of NASDA, which were connected by tele-communication links. Manipulators respective for a microelectrode and a sample stage of microscope were moved by computers, of which command signals were transmitted from a computer in a remote control room. The computer in the control room was operated by an investigator (PI) who controlled the movement of each manipulator remotely. A stereoscopic vision of the microscope image were prepared by using a head mounted display (HMD) and were indispensable to the intracellular single cell recording. The fertilization potential of amphibian eggs was successfully obtained through the remote operating system.

  7. New student-designed research and demonstration drop tower

    NASA Astrophysics Data System (ADS)

    Bell, Donald; Weislogel, Mark

    A new drop tower has been designed and constructed at Portland State University. The ap-proach incorporates innovative features to increase throughput and microgravity quality in a highly public facility. Push button operation with full wireless CCTV coverage and passive magnetic deceleration provides quiet, safe operation from a single control station with low re-cycle time. A two-stage coaxial release mechanism decouples the payload from the drag shield to minimize disturbances to the experiment during release. This is especially important for fluids experiments that are highly sensitive to initial conditions. Performance of the new tower is presented including release, free fall, and deceleration accelerometer data. The two second tower is used for research and educational outreach. The research efforts focus on capillary flows and phenomena relevant to spacecraft fluid systems. The outreach efforts utilize partnerships with local primary, secondary and post-secondary institutions to promote the fields of science, technology, engineering and mathematics.

  8. Weather forecasting expert system study

    NASA Technical Reports Server (NTRS)

    1985-01-01

    Weather forecasting is critical to both the Space Transportation System (STS) ground operations and the launch/landing activities at NASA Kennedy Space Center (KSC). The current launch frequency places significant demands on the USAF weather forecasters at the Cape Canaveral Forecasting Facility (CCFF), who currently provide the weather forecasting for all STS operations. As launch frequency increases, KSC's weather forecasting problems will be great magnified. The single most important problem is the shortage of highly skilled forecasting personnel. The development of forecasting expertise is difficult and requires several years of experience. Frequent personnel changes within the forecasting staff jeopardize the accumulation and retention of experience-based weather forecasting expertise. The primary purpose of this project was to assess the feasibility of using Artificial Intelligence (AI) techniques to ameliorate this shortage of experts by capturing aria incorporating the forecasting knowledge of current expert forecasters into a Weather Forecasting Expert System (WFES) which would then be made available to less experienced duty forecasters.

  9. Viscoplastic analysis of an experimental cylindrical thrust chamber liner

    NASA Technical Reports Server (NTRS)

    Arya, Vinod K.; Arnold, Steven M.

    1991-01-01

    A viscoplastic stress-strain analysis of an experimental cylindrical thrust chamber is presented. A viscoelastic constitutive model incorporating a single internal state variable that represents kinematic hardening was employed to investigate whether such a viscoplastic model could predict the experimentally observed behavior of the thrust chamber. Two types of loading cycles were considered: a short cycle of 3.5 sec. duration that corresponded to the experiments, and an extended loading cycle of 485.1 sec. duration that is typical of the Space Shuttle Main Engine (SSME) operating cycle. The analysis qualitatively replicated the deformation behavior of the component as observed in experiments designed to simulate SSME operating conditions. The analysis also showed that the mode and location in the component may depend on the loading cycle. The results indicate that using viscoplastic models for structural analysis can lead to a more realistic life assessment of thrust chambers.

  10. SIN accelerator, operational experience and improvement programs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Joho, W.; Olivo, M.; Stammbach, T.

    1977-06-01

    The SIN meson facility, in operation since 1974, consists of a 590 MeV ring cyclotron for protons and a 72 MeV injector cyclotron. The average beam current on target is presently about 50 ..mu..A, the peak being 112 ..mu..A. Extraction efficiency, once considered a severe handicap for cyclotrons, is now 99.6 to 99.9% for the ring cyclotron and about 90% for the injector. Many improvements in both accelerators allow single turn extraction in the ring cyclotron. The present current limit is given by the injector, while the ring itself could accept now a 600 ..mu..A beam, with 2 to 4more » mA as an ultimate limit. Some muon experiments require a pulsed beam with on-off times in the order of the lifetime of the muon. First trials with beam pulse frequencies of 200 and 400 kHz and a 50% duty cycle have been successful.« less

  11. High-Intensity Radiated Field Fault-Injection Experiment for a Fault-Tolerant Distributed Communication System

    NASA Technical Reports Server (NTRS)

    Yates, Amy M.; Torres-Pomales, Wilfredo; Malekpour, Mahyar R.; Gonzalez, Oscar R.; Gray, W. Steven

    2010-01-01

    Safety-critical distributed flight control systems require robustness in the presence of faults. In general, these systems consist of a number of input/output (I/O) and computation nodes interacting through a fault-tolerant data communication system. The communication system transfers sensor data and control commands and can handle most faults under typical operating conditions. However, the performance of the closed-loop system can be adversely affected as a result of operating in harsh environments. In particular, High-Intensity Radiated Field (HIRF) environments have the potential to cause random fault manifestations in individual avionic components and to generate simultaneous system-wide communication faults that overwhelm existing fault management mechanisms. This paper presents the design of an experiment conducted at the NASA Langley Research Center's HIRF Laboratory to statistically characterize the faults that a HIRF environment can trigger on a single node of a distributed flight control system.

  12. Summary of results from the Tandem Mirror Experiment (TMX)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Simonen, T.C.

    1981-02-26

    This report summarizes results from the successful experimental operation of the Tandem Mirror Experiment (TMX) over the period October 1978 through September 1980. The experimental program, summarized by the DOE milestones given in Table 1-1, had three basic phases: (1) an 8-month checkout period, October 1978 through May 1979; (2) a 6-month initial period of operation, June through November 1979, during which the basic principles of the tandem configuration were demonstrated (i.e., plasma confinement was improved over that of a single-cell mirror); and (3) a 10-month period, December 1979 through September 1980, during which the initial TMX results were corroboratedmore » by additional diagnostic measurements and many detailed physics investigations were carried out. This report summarizes the early results, presents results of recent data analysis, and outlines areas of ongoing research and data analysis which will be reported in future journal publications.« less

  13. Preliminary experience and learning curve for laparoendoscopic single-site retroperitoneal pyeloplasty.

    PubMed

    Ou, Zhenyu; Qi, Lin; Yang, Jinrui; Chen, Xiang; Cao, Zhenzhen; Zu, Xiongbing; Liu, Longfei; Wang, Long

    2013-09-01

    To report our preliminary experience and to assess the learning curve for laparoendoscopic single-site retroperitoneal pyeloplasty (LESS-RP) for ureteropelvic junction obstruction (UPJO). From July 2010 to February 2012, LESS-RP was performed in 27 patients affected with UPJO by a single surgeon. A homemade single-access platform and both conventional and prebent instruments were applied. Patient characteristics and perioperative outcomes were analyzed. The cumulative sum (CUSUM) method was used to evaluate the learning curve. The LESS-RP was successfully accomplished in all 27 patients. The mean operative time (OT) was 175.9±22.5 minutes, and the mean estimated blood loss was 83.3±27.1 mL. We used the OT as a proxy to assess the learning curve. The CUSUM learning curve can be divided into two distinct phases: the initial 12 cases and the last 15 cases. There were significant differences in the mean OT (195.6 minutes versus 159.1 minutes, P<.001) and mean estimated blood loss (97.2 mL versus 72.2 mL, P=.014) between the two phases. The two phases did not differ in other parameters. LESS-RP is a safe and feasible procedure. The learning curve of a single surgeon suggests that the initial learning phase for LESS-RP can be completed after approximately 12 cases.

  14. Covariance-based synaptic plasticity in an attractor network model accounts for fast adaptation in free operant learning.

    PubMed

    Neiman, Tal; Loewenstein, Yonatan

    2013-01-23

    In free operant experiments, subjects alternate at will between targets that yield rewards stochastically. Behavior in these experiments is typically characterized by (1) an exponential distribution of stay durations, (2) matching of the relative time spent at a target to its relative share of the total number of rewards, and (3) adaptation after a change in the reward rates that can be very fast. The neural mechanism underlying these regularities is largely unknown. Moreover, current decision-making neural network models typically aim at explaining behavior in discrete-time experiments in which a single decision is made once in every trial, making these models hard to extend to the more natural case of free operant decisions. Here we show that a model based on attractor dynamics, in which transitions are induced by noise and preference is formed via covariance-based synaptic plasticity, can account for the characteristics of behavior in free operant experiments. We compare a specific instance of such a model, in which two recurrently excited populations of neurons compete for higher activity, to the behavior of rats responding on two levers for rewarding brain stimulation on a concurrent variable interval reward schedule (Gallistel et al., 2001). We show that the model is consistent with the rats' behavior, and in particular, with the observed fast adaptation to matching behavior. Further, we show that the neural model can be reduced to a behavioral model, and we use this model to deduce a novel "conservation law," which is consistent with the behavior of the rats.

  15. Coparenting Experiences in African American Families: An Examination of Single Mothers and their Non-Marital Coparents

    PubMed Central

    Gonzalez, Michelle; Jones, Deborah J.; Parent, Justin

    2015-01-01

    African American youth from single mother homes continue to be overrepresented in statistics on risk behavior and delinquency, a trend that many be attributed to father-absence, socioeconomic disadvantage, and compromises in parenting more typical of single than two-parent families. Yet, this risk-focused perspective ignores a long-standing strength of the African American community, the involvement and potential protective impact of extended family members in childrearing. This study describes the experiences of 95 African American single mothers and their non-marital coparents who participated in a study of African American single mother families with an 11 to 16 year old child. Specifically, the study examines: 1) the extent to which nonmarital coparents are involved in childrearing; 2) the relative levels of risk (i.e., depression, mother-coparent conflict) and protective (i.e., parenting) associated with maternal and coparent involvement; and 3) how similarly and/or differently coparent and mother variables operate with regard to youth externalizing problems. Findings reveal that a range of family members and other adults actively participate in childrearing in African American single mother families, coparents do not differ from mothers on certain study variables (i.e., depression and mother-coparent conflict) but do for others (parenting), and coparent involvement is associated with youth adjustment in ways that are similar to our more established understanding of maternal involvement. The potential clinical implications of the findings are discussed and future research directions are highlighted. PMID:24479612

  16. Coparenting experiences in African American families: an examination of single mothers and their nonmarital coparents.

    PubMed

    Gonzalez, Michelle; Jones, Deborah; Parent, Justin

    2014-03-01

    African American youth from single-mother homes continue to be overrepresented in statistics on risk behavior and delinquency, a trend that many be attributed to father-absence, socioeconomic disadvantage, and compromises in parenting more typical of single than two-parent families. Yet, this risk-focused perspective ignores a long-standing strength of the African American community, the involvement and potential protective impact of extended family members in childrearing. This study describes the experiences of 95 African American single mothers and their nonmarital coparents who participated in a study of African American single-mother families with an 11-16-year-old child. Specifically, the study examines: (a) the extent to which nonmarital coparents are involved in childrearing; (b) the relative levels of risk (i.e., depression, mother-coparent conflict) and protective (i.e., parenting) associated with maternal and coparent involvement; and (c) how similarly and/or differently coparent and mother variables operate with regard to youth externalizing problems. Findings reveal that a range of family members and other adults actively participate in childrearing in African American single-mother families, coparents do not differ from mothers on certain study variables (i.e., depression and mother-coparent conflict) but do for others (parenting), and coparent involvement is associated with youth adjustment in ways that are similar to our more established understanding of maternal involvement. The potential clinical implications of the findings are discussed and future research directions are highlighted. © 2014 FPI, Inc.

  17. Addressable single-spin control in multiple quantum dots coupled in series

    NASA Astrophysics Data System (ADS)

    Nakajima, Takashi

    2015-03-01

    Electron spin in semiconductor quantum dots (QDs) is promising building block of quantum computers for its controllability and potential scalability. Recent experiments on GaAs QDs have demonstrated necessary ingredients of universal quantum gate operations: single-spin rotations by electron spin resonance (ESR) which is virtually free from the effect of nuclear spin fluctuation, and pulsed control of two-spin entanglement. The scalability of this architecture, however, has remained to be demonstrated in the real world. In this talk, we will present our recent results on implementing single-spin-based qubits in triple, quadruple, and quintuple QDs based on a series coupled architecture defined by gate electrodes. Deterministic initialization of individual spin states and spin-state readout were performed by the pulse operation of detuning between two neighboring QDs. The spin state was coherently manipulated by ESR, where each spin in different QDs is addressed by the shift of the resonance frequency due to the inhomogeneous magnetic field induced by the micro magnet deposited on top of the QDs. Control of two-spin entanglement was also demonstrated. We will discuss key issues for implementing quantum algorithms based on three or more qubits, including the effect of a nuclear spin bath, single-shot readout fidelity, and tuning of multiple qubit devices. Our approaches to these issues will be also presented. This research is supported by Funding Program for World-Leading Innovative R&D on Science and Technology (FIRST) from JSPS, IARPA project ``Multi-Qubit Coherent Operations'' through Copenhagen University, and Grant-in-Aid for Scientific Research from JSPS.

  18. Readiness of the ATLAS detector: Performance with the first beam and cosmic data

    NASA Astrophysics Data System (ADS)

    Pastore, F.

    2010-05-01

    During 2008 the ATLAS experiment went through an intense period of preparation to have the detector fully commissioned for the first beam period. In about 30 h of beam time available to ATLAS in 2008 the systems went through a rapid setup sequence, from successfully recording the first bunch ever reaching ATLAS, to setting up the timing of the trigger system synchronous to the incoming single beams. The so-called splash events were recorded, where the beam was stopped on a collimator 140 m upstream of ATLAS, showering the experiment with millions of particles per beam shot. These events were found to be extremely useful for timing setup. After the stop of the beam operation, the experiment went through an extensive cosmic ray data taking campaign, recording more than 500 million cosmic ray events. These events have been used to make significant progress on the calibration and alignment of the detector. This paper describes the commissioning programme and the results obtained from both the single beam data and the cosmic data recorded in 2008.

  19. Pseudo-single-bunch mode for a 100 MHz storage ring serving soft X-ray timing experiments

    NASA Astrophysics Data System (ADS)

    Olsson, T.; Leemann, S. C.; Georgiev, G.; Paraskaki, G.

    2018-06-01

    At many storage rings for synchrotron light production there is demand for serving both high-flux and timing users simultaneously. Today this is most commonly achieved by operating inhomogeneous fill patterns, but this is not preferable for rings that employ passive harmonic cavities to damp instabilities and increase Touschek lifetime. For these rings, inhomogeneous fill patterns could severely reduce the effect of the harmonic cavities. It is therefore of interest to develop methods to serve high-flux and timing users simultaneously without requiring gaps in the fill pattern. One such method is pseudo-single-bunch (PSB), where one bunch in the bunch train is kicked onto another orbit by a fast stripline kicker. The light emitted from the kicked bunch can then be separated by an aperture in the beamline. Due to recent developments in fast kicker design, PSB operation in multibunch mode is within reach for rings that operate with a 100 MHz RF system, such as the MAX IV and Solaris storage rings. This paper describes machine requirements and resulting performance for such a mode at the MAX IV 1.5 GeV storage ring. A solution for serving all beamlines is discussed as well as the consequences of beamline design and operation in the soft X-ray energy range.

  20. Social recognition is context dependent in single male prairie voles

    PubMed Central

    Zheng, Da-Jiang; Foley, Lauren; Rehman, Asad; Ophir, Alexander G.

    2013-01-01

    Single males might benefit from knowing the identity of neighbouring males when establishing and defending boundaries. Similarly, males should discriminate between individual females if this leads to more reproductive opportunities. Contextual social cues may alter the value of learning identity. Knowing the identity of competitors that intrude into an animal’s territory may be more salient than knowing the identity of individuals on whose territory an animal is trespassing. Hence, social and environmental context could affect social recognition in many ways. Here we test social recognition of socially monogamous single male prairie voles, Microtus ochrogaster. In experiment 1 we tested recognition of male or female conspecifics and found that males discriminated between different males but not between different females. In experiment 2 we asked whether recognition of males is influenced when males are tested in their own cage (familiar), in a clean cage (neutral) or in the home cage of another male (unfamiliar). Although focal males discriminated between male conspecifics in all three contexts, individual variation in recognition was lower when males were tested in their home cage (in the presence of familiar social cues) compared to when the context lacked social cues (neutral). Experiment 1 indicates that selective pressures may have operated to enhance male territorial behaviour and indiscriminate mate selection. Experiment 2 suggests that the presence of a conspecific cue heightens social recognition and that home-field advantages might extend to social cognition. Taken together, our results indicate social recognition depends on the social and possibly territorial context. PMID:24273328

  1. Social recognition is context dependent in single male prairie voles.

    PubMed

    Zheng, Da-Jiang; Foley, Lauren; Rehman, Asad; Ophir, Alexander G

    2013-11-01

    Single males might benefit from knowing the identity of neighbouring males when establishing and defending boundaries. Similarly, males should discriminate between individual females if this leads to more reproductive opportunities. Contextual social cues may alter the value of learning identity. Knowing the identity of competitors that intrude into an animal's territory may be more salient than knowing the identity of individuals on whose territory an animal is trespassing. Hence, social and environmental context could affect social recognition in many ways. Here we test social recognition of socially monogamous single male prairie voles, Microtus ochrogaster . In experiment 1 we tested recognition of male or female conspecifics and found that males discriminated between different males but not between different females. In experiment 2 we asked whether recognition of males is influenced when males are tested in their own cage (familiar), in a clean cage (neutral) or in the home cage of another male (unfamiliar). Although focal males discriminated between male conspecifics in all three contexts, individual variation in recognition was lower when males were tested in their home cage (in the presence of familiar social cues) compared to when the context lacked social cues (neutral). Experiment 1 indicates that selective pressures may have operated to enhance male territorial behaviour and indiscriminate mate selection. Experiment 2 suggests that the presence of a conspecific cue heightens social recognition and that home-field advantages might extend to social cognition. Taken together, our results indicate social recognition depends on the social and possibly territorial context.

  2. Advanced Reciprocating Engine Systems (ARES) Research at Argonne National Laboratory. A Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gupta, Sreenath; Biruduganti, Muni; Bihari, Bipin

    The goals of these experiments were to determine the potential of employing spectral measurements to deduce combustion metrics such as HRR, combustion temperatures, and equivalence ratios in a natural gas-fired reciprocating engine. A laser-ignited, natural gas-fired single-cylinder research engine was operated at various equivalence ratios between 0.6 and 1.0, while varying the EGR levels between 0% and maximum to thereby ensure steady combustion. Crank angle-resolved spectral signatures were collected over 266-795 nm, encompassing chemiluminescence emissions from OH*, CH*, and predominantly by CO2* species. Further, laser-induced gas breakdown spectra were recorded under various engine operating conditions.

  3. Manned Systems Utilization Analysis. Study 2.1: Space Servicing Pilot Program Study. [for automated payloads

    NASA Technical Reports Server (NTRS)

    Wolfe, R. R.

    1975-01-01

    Space servicing automated payloads was studied for potential cost benefits for future payload operations. Background information is provided on space servicing in general, and on a pilot flight test program in particular. An fight test is recommended to demonstrate space servicing. An overall program plan is provided which builds upon the pilot program through an interim servicing capability. A multipayload servicing concept for the time when the full capability tug becomes operational is presented. The space test program is specifically designed to provide low-cost booster vehicles and a flight test platform for several experiments on a single flight.

  4. Rotorcraft digital advanced avionics system (RODAAS) functional description

    NASA Technical Reports Server (NTRS)

    Peterson, E. M.; Bailey, J.; Mcmanus, T. J.

    1985-01-01

    A functional design of a rotorcraft digital advanced avionics system (RODAAS) to transfer the technology developed for general aviation in the Demonstration Advanced Avionics System (DAAS) program to rotorcraft operation was undertaken. The objective was to develop an integrated avionics system design that enhances rotorcraft single pilot IFR operations without increasing the required pilot training/experience by exploiting advanced technology in computers, busing, displays and integrated systems design. A key element of the avionics system is the functionally distributed architecture that has the potential for high reliability with low weight, power and cost. A functional description of the RODAAS hardware and software functions is presented.

  5. A Single Institution Review of Initial Application of a 5-mm Stapler.

    PubMed

    Rogers, Andrew P; Zens, Tiffany J; Kohler, Jonathan E; Le, Hau D; Nichol, Peter F; Leys, Charles M

    2016-08-01

    Operating in small spaces presents physical constraints that can be even more challenging in minimally invasive operations. Recently, a 5-mm stapler was approved for use in general surgery and pediatric surgery. Here, we present our initial experience using the 5-mm stapler in pediatric general surgery. A retrospective chart review was conducted to identify cases using the 5-mm stapler at our institution. Demographic data included age (in months) and weight (in kilograms). Operative data included indication for use, number of loads used, complications related to 5-mm stapler use, and interventions to address complications. A second review focused on patients undergoing the same operations, but using a 10-mm stapler. A total of 60 staple loads were deployed in 32 procedures. There were four adverse outcomes, all recognized intraoperatively. One bleed resulted from application on irradiated tissue and another bleed from application to a small noninflamed mesoappendix. A bronchial staple line leak resulted from improper stapler loading, and a bowel anastomosis leak was oversewn with a single stitch. When compared with 32 matched cases using a 10-mm stapler, there was no difference in age (5-mm = 39.11 months, 10-mm = 50.21 months, P = .49) or weight (5-mm = 16.34 kg, 10-mm = 19.93 kg, P = .51). A total of 60 staple applications were used, with one bleed noted. There was no significant difference in overall complication rate (5-mm rate = 4/60, 10-mm rate = 1/60; P = .36). Our initial experience suggests that although there were more complications with the 5-mm stapler, there is no statistically significant difference in complication rates when compared with the 10-mm stapler. Furthermore, the 5-mm stapler complications can be corrected with device training and proper patient selection. In appropriately selected pediatric surgery cases with size limitations, the 5-mm stapler can be used to minimize the invasiveness of the operation.

  6. Transanal endoscopic surgery using a single access port: a practical tool in the surgeon's toybox.

    PubMed

    Gorgun, I E; Gorgun, I Emre; Aytac, Erman; Costedio, Meagan M; Erem, Hasan H; Valente, Michael A; Stocchi, Luca

    2014-03-01

    Large polyps and early carcinomas of the rectum may be excised with transanal endoscopic surgery (TES). Single-port techniques are emerging in the field of colorectal surgery and have been adapted to many colorectal procedures so far. In this article, we aimed to present our initial experience with TES using a single access port with its technical details. Patients undergoing TES using a single access port between July 2010 and January 2013 were included in the study. Patient demographics, operative technique, and both operative and postoperative outcomes were evaluated and presented. A total of 12 patients (ten males) were included in our study. The median age was 63.5 years (50-84), median American Society of Anesthesiologists (ASA) score was 3 (2-4), and median body mass index was 28.8 kg/m(2) (17.4-55.6). Median operating time was 79 min (43-261). Histopathological diagnoses were as follows: tubulovillous adenoma (n = 6), tubular adenoma (n = 4), adenocarcinoma (n = 1), and neuroendocrine tumor (n = 1). Five patients were sent home on the day of surgery and the median postoperative hospital stay was 1 day (0-38). Median estimated blood loss was 22.5 ml (5-150). A transient urinary retention was developed in one patient postoperatively, and two patients had postoperative bleeding. The first of these patients with a long history of anticoagulant usage had rectal bleeding 13 days after surgery, which was successfully managed with medical treatment. The second patient was morbidly obese, had multiple comorbidities, and had rectal bleeding on postoperative day 7 which was managed with local epinephrine injection. He suffered unrelated cardiac death on postoperative day 38. TES is safe and feasible when using a single port and in the standard laparoscopic setting. The single-port technique may play a major role in the widespread utilization of TES as a treatment for large adenomas and early rectal cancers.

  7. DNA Repair by DNA: The UV1C DNAzyme Catalyzes Photoreactivation of Cyclobutane Thymine Dimers in DNA More Effectively than Their de Novo Formation.

    PubMed

    Barlev, Adam; Sekhon, Gurpreet S; Bennet, Andrew J; Sen, Dipankar

    2016-11-01

    UV1C, a 42-nt DNA oligonucleotide, is a deoxyribozyme (DNAzyme) that optimally uses 305 nm wavelength light to catalyze photoreactivation of a cyclobutane thymine dimer placed within a gapped, unnatural DNA substrate, TDP. Herein we show that UV1C is also capable of photoreactivating thymine dimers within an authentic single-stranded DNA substrate, LDP. This bona fide UV1C substrate enables, for the first time, investigation of whether UV1C catalyzes only photoreactivation or also the de novo formation of thymine dimers. Single-turnover experiments carried out with LDP and UV1C, relative to control experiments with LDP alone in single-stranded and double-stranded contexts, show that while UV1C does modestly promote thymine dimer formation, its major activity is indeed photoreactivation. Distinct photostationary states are reached for LDP in its three contexts: as a single strand, as a constituent of a double-helix, and as a 1:1 complex with UV1C. The above results on the cofactor-independent photoreactivation capabilities of a catalytic DNA reinforce a series of recent, unexpected reports that purely nucleotide-based photoreactivation is also operational within conventional double-helical DNA.

  8. Learning Curve Analysis and Surgical Outcomes of Single-port Laparoscopic Myomectomy.

    PubMed

    Lee, Hee Jun; Kim, Ju Yeong; Kim, Seul Ki; Lee, Jung Ryeol; Suh, Chang Suk; Kim, Seok Hyun

    2015-01-01

    To identify learning curves for single-port laparoscopic myomectomy (SPLM) and evaluate surgical outcomes according to the sequence of operation. A retrospective study. A university-based hospital (Canadian Task Force classification II-2). The medical records from 205 patients who had undergone SPLM from October 2009 to May 2013 were reviewed. Because the myomectomy time was significantly affected by the size and number of myomas removed by SPLM, cases in which 2 or more of the myomas removed were >7 cm in diameter were excluded. Furthermore, cases involving additional operations performed simultaneously (e.g., ovarian or hysteroscopic surgery) were also excluded. A total of 161 cases of SPLM were included. None. We assessed the SPLM learning curve via a graph based on operation time versus sequence of cases. Patients were chronologically arranged according to their surgery dates and were then placed into 1 of 4 groups according to their operation sequence. SPLM was completed successfully in 160 of 161 cases (99.4%). One case was converted to multiport surgery. Basal characteristics of the patients between the 4 groups did not differ. The median operation times for the 4 groups were 112.0, 92.8, 83.7, and 90.0 minutes, respectively. Operation time decreased significantly in the second, third, and fourth groups compared with that in the first group (p < .001). Proficiency, which is the point at which the slope of the learning curve became less steep, was evident after about 45 operations. Results from the current study suggested that proficiency for SPLM was achieved after about 45 operations. Additionally, operation time decreased with experience without an increase in complication rate. Copyright © 2015 AAGL. Published by Elsevier Inc. All rights reserved.

  9. Measurement of fetal head descent using the 'angle of progression' on transperineal ultrasound imaging is reliable regardless of fetal head station or ultrasound expertise.

    PubMed

    Dückelmann, A M; Bamberg, C; Michaelis, S A M; Lange, J; Nonnenmacher, A; Dudenhausen, J W; Kalache, K D

    2010-02-01

    To assess whether ultrasound experience or fetal head station affects the reliability of measurement of fetal head descent using the angle of progression on intrapartum ultrasound images obtained by a single experienced operator, and to determine reliability of measurements when images were acquired by different operators with variable ultrasound experience. One experienced obstetrician performed 44 transperineal ultrasound examinations of women at term and in prolonged second stage of labor with the fetus in the occipitoanterior position. Three midwives without ultrasound experience, three obstetricians with < 5 years' experience and three obstetricians with > 10 years' experience measured fetal head descent based on the angle of progression in the images obtained. The angle of progression was measured by two obstetricians in independent ultrasound examinations of 24 laboring women at term with the fetus in the cephalic position to allow assessment of the reliability of image acquisition. Intraclass correlation coefficients (ICCs) with 95% confidence interval (CI) were used to evaluate interobserver reliability and Bland-Altman analysis was used to assess interobserver agreement. In total, 444 measurements were performed and compared. Interobserver reliability with respect to offline image analysis was substantial (overall ICC, 0.72; 95% CI, 0.63-0.81). ICCs were 0.82 (95% CI, 0.70-0.89), 0.81 (95% CI, 0.71-0.88) and 0.61 (95% CI, 0.43-074) for observers with > 10 years', < 5 years' and no ultrasound experience, respectively. There were no significant differences between ICCs among observer groups according to ultrasound experience. Fetal head station did not affect reliability. Bland-Altman analysis indicated reasonable agreement between measurements obtained by two different operators with > 10 years' and < 5 years' ultrasound experience (bias, -1.09 degrees ; 95% limits of agreement, -8.76 to 6.58). The reliability of measurement of the angle of progression following separate image acquisition by two experienced operators was similar to the reliability of offline image analysis (ICC, 0.86; 95% CI, 0.70-0.93). Measurement of the angle of progression on transperineal ultrasound imaging is reliable regardless of fetal head station or the clinician's level of ultrasound experience.

  10. Silicon photonics WDM transmitter with single section semiconductor mode-locked laser

    NASA Astrophysics Data System (ADS)

    Müller, Juliana; Hauck, Johannes; Shen, Bin; Romero-García, Sebastian; Islamova, Elmira; Azadeh, Saeed Sharif; Joshi, Siddharth; Chimot, Nicolas; Moscoso-Mártir, Alvaro; Merget, Florian; Lelarge, François; Witzens, Jeremy

    2015-04-01

    We demonstrate a wavelength domain-multiplexed (WDM) optical link relying on a single section semiconductor mode-locked laser (SS-MLL) with quantum dash (Q-Dash) gain material to generate 25 optical carriers spaced by 60.8 GHz, as well as silicon photonics (SiP) resonant ring modulators (RRMs) to modulate individual optical channels. The link requires optical reamplification provided by an erbium-doped fiber amplifier (EDFA) in the system experiments reported here. Open eye diagrams with signal quality factors (Q-factors) above 7 are measured with a commercial receiver (Rx). For higher compactness and cost effectiveness, reamplification of the modulated channels with a semiconductor optical amplifier (SOA) operated in the linear regime is highly desirable. System and device characterization indicate compatibility with the latter. While we expect channel counts to be primarily limited by the saturation output power level of the SOA, we estimate a single SOA to support more than eight channels. Prior to describing the system experiments, component design and detailed characterization results are reported including design and characterization of RRMs, ring-based resonant optical add-drop multiplexers (RR-OADMs) and thermal tuners, S-parameters resulting from the interoperation of RRMs and RR-OADMs, and characterization of Q-Dash SS-MLLs reamplified with a commercial SOA. Particular emphasis is placed on peaking effects in the transfer functions of RRMs and RR-OADMs resulting from transient effects in the optical domain, as well as on the characterization of SS-MLLs in regard to relative intensity noise (RIN), stability of the modes of operation, and excess noise after reamplification.

  11. System integration of RF based negative ion experimental facility at IPR

    NASA Astrophysics Data System (ADS)

    Bansal, G.; Bandyopadhyay, M.; Singh, M. J.; Gahlaut, A.; Soni, J.; Pandya, K.; Parmar, K. G.; Sonara, J.; Chakraborty, A.

    2010-02-01

    The setting up of RF based negative ion experimental facility shall witness the beginning of experiments on the negative ion source fusion applications in India. A 1 MHz RF generator shall launch 100 kW RF power into a single driver on the plasma source to produce a plasma of density ~5 × 1012 cm-3. The source can deliver a negative ion beam of ~10 A with a current density of ~30 mA/cm2 and accelerated to 35 kV through an electrostatic ion accelerator. The experimental system is similar to a RF based negative ion source, BATMAN, presently operating at IPP. The subsystems for source operation are designed and procured principally from indigenous resources, keeping the IPP configuration as a base line. The operation of negative ion source is supported by many subsystems e.g. vacuum pumping system with gate valves, cooling water system, gas feed system, cesium delivery system, RF generator, high voltage power supplies, data acquisition and control system, and different diagnostics. The first experiments of negative ion source are expected to start at IPR from the middle of 2009.

  12. The link evaluation terminal for the advanced communications technology satellite experiments program

    NASA Technical Reports Server (NTRS)

    May, Brian D.

    1992-01-01

    The experimental NASA satellite, Advanced Communications Technology Satellite (ACTS), introduces new technology for high throughput 30 to 20 GHz satellite services. Contained in a single communication payload is both a regenerative TDMA system and multiple 800 MHz 'bent pipe' channels routed to spot beams by a switch matrix. While only one mode of operation is typical during any experiment, both modes can operate simultaneously with reduced capability due to sharing of the transponder. NASA-Lewis instituted a ground terminal development program in anticipation of the satellite launch to verify the performance of the switch matrix mode of operations. Specific functions are built into the ground terminal to evaluate rain fade compensation with uplink power control and to monitor satellite transponder performance with bit error rate measurements. These functions were the genesis of the ground terminal's name, Link Evaluation Terminal, often referred to as LET. Connectors are included in LET that allow independent experimenters to run unique modulation or network experiments through ACTS using only the RF transmit and receive portions of LET. Test data indicate that LET will be able to verify important parts of ACTS technology and provide independent experimenters with a useful ground terminal. Lab measurements of major subsystems integrated into LET are presented. Bit error rate is measured with LET in an internal loopback mode.

  13. Techniques for studying gravity waves and turbulence: Vertical wind speed power spectra from the troposphere and stratosphere obtained under light wind conditions

    NASA Technical Reports Server (NTRS)

    Ecklund, W. L.; Balsley, B. B.; Crochet, M.; Carter, D. A.; Riddle, A. C.; Garello, R.

    1983-01-01

    A joint France/U.S. experiment was conducted near the mouth of the Rhone river in southern France as part of the ALPEX program. This experiment used 3 vertically directed 50 MHz radars separated by 4 to 6 km. The main purpose of this experiment was to study the spatial characteristics of gravity waves. The good height resolution (750 meters) and time resolution (1 minute) and the continuous operation over many weeks have yielded high resolution vertical wind speed power spectra under a variety of synoptic conditions. Vertical spectra obtained during very quiet (low wind) conditions in the troposphere and lower stratosphere from a single site are presented.

  14. Single-mode fiber, velocity interferometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Krauter, K. G.; Jacobson, G. F.; Patterson, J. R.

    2011-04-15

    In this paper, we describe a velocity interferometer system based entirely on single-mode fiber optics. This paper includes a description of principles used in developing the single-mode velocity interferometry system (SMV). The SMV design is based on polarization-insensitive components. Polarization adjusters are included to eliminate the effects of residual birefringence and polarization dependent losses in the interferometers. Characterization measurements and calibration methods needed for data analysis and a method of data analysis are described. Calibration is performed directly using tunable lasers. During development, we demonstrated its operation using exploding-foil bridge-wire fliers up to 200 m/s. In a final test, wemore » demonstrated the SMV in a gas gun experiment up to 1.2 km/sec. As a basis for comparison in the gas gun experiment, we used another velocimetry technique that is also based on single-mode fiber optics: photonic Doppler velocimetry (PDV). For the gas gun experiment, we split the light returned from a single target spot and performed a direct comparison of the homodyne (SMV) and heterodyne (PDV) techniques concurrently. The two techniques had a negligible mean difference and a 1.5% standard deviation in the one-dimensional shock zone. Within one interferometer delay time after a sudden Doppler shift, a SMV unencumbered by multimode-fiber dispersion exhibits two color beats. These beats have the same period as PDV beats--this interference occurs between the ''recently'' shifted and ''formerly unshifted'' paths within the interferometer. We believe that recognizing this identity between homodyne and heterodyne beats is novel in the shock-physics field. SMV includes the conveniences of optical fiber, while removing the time resolution limitations associated with the multimode delivery fiber.« less

  15. Single-mode fiber, velocity interferometry.

    PubMed

    Krauter, K G; Jacobson, G F; Patterson, J R; Nguyen, J H; Ambrose, W P

    2011-04-01

    In this paper, we describe a velocity interferometer system based entirely on single-mode fiber optics. This paper includes a description of principles used in developing the single-mode velocity interferometry system (SMV). The SMV design is based on polarization-insensitive components. Polarization adjusters are included to eliminate the effects of residual birefringence and polarization dependent losses in the interferometers. Characterization measurements and calibration methods needed for data analysis and a method of data analysis are described. Calibration is performed directly using tunable lasers. During development, we demonstrated its operation using exploding-foil bridge-wire fliers up to 200 m/s. In a final test, we demonstrated the SMV in a gas gun experiment up to 1.2 km/sec. As a basis for comparison in the gas gun experiment, we used another velocimetry technique that is also based on single-mode fiber optics: photonic Doppler velocimetry (PDV). For the gas gun experiment, we split the light returned from a single target spot and performed a direct comparison of the homodyne (SMV) and heterodyne (PDV) techniques concurrently. The two techniques had a negligible mean difference and a 1.5% standard deviation in the one-dimensional shock zone. Within one interferometer delay time after a sudden Doppler shift, a SMV unencumbered by multimode-fiber dispersion exhibits two color beats. These beats have the same period as PDV beats-this interference occurs between the "recently" shifted and "formerly unshifted" paths within the interferometer. We believe that recognizing this identity between homodyne and heterodyne beats is novel in the shock-physics field. SMV includes the conveniences of optical fiber, while removing the time resolution limitations associated with the multimode delivery fiber. © 2011 American Institute of Physics

  16. Joint remote control of an arbitrary single-qubit state by using a multiparticle entangled state as the quantum channel

    NASA Astrophysics Data System (ADS)

    Lv, Shu-Xin; Zhao, Zheng-Wei; Zhou, Ping

    2018-01-01

    We present a scheme for joint remote implementation of an arbitrary single-qubit operation following some ideas in one-way quantum computation. All the senders share the information of implemented quantum operation and perform corresponding single-qubit measurements according to their information of implemented operation. An arbitrary single-qubit operation can be implemented upon the remote receiver's quantum system if the receiver cooperates with all the senders. Moreover, we study the protocol of multiparty joint remote implementation of an arbitrary single-qubit operation with many senders by using a multiparticle entangled state as the quantum channel.

  17. A switchable and stable single-longitudinal-mode, dual-wavelength erbium-doped fiber laser assisted by Rayleigh backscattering in tapered fiber

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gu, Jian; Yang, Yanfu, E-mail: yangyanfu@hotmail.com; Zhang, Jianyu

    We have proposed and demonstrated a novel switchable single-longitudinal-mode (SLM), dual-wavelength erbium-doped fiber laser (DWEDFL) assisted by Rayleigh backscattering (RBS) in a tapered fiber in a ring laser configuration. The RBS feedback in a tapered fiber is a key mechanism as linewidth narrowing for laser output. A compound laser cavity ensured that the EDFL operated in the SLM state and a saturable absorber (SA) is employed to form a gain grating for both filtering and improving wavelength stability. The fiber laser can output dual wavelengths simultaneously or operate at single wavelength in a switchable manner. Experiment results show that withmore » the proper SA, the peak power drift was improved from 1–2 dB to 0.31 dB and the optical signal to noise ratio was higher than 60 dB. Under the assistance of RBS feedback, the laser linewidths are compressed by around three times and the Lorentzian 3 dB linewidths of 445 Hz and 425 Hz are obtained at 1550 nm and 1554 nm, respectively.« less

  18. Octopus vulgaris uses visual information to determine the location of its arm.

    PubMed

    Gutnick, Tamar; Byrne, Ruth A; Hochner, Binyamin; Kuba, Michael

    2011-03-22

    Octopuses are intelligent, soft-bodied animals with keen senses that perform reliably in a variety of visual and tactile learning tasks. However, researchers have found them disappointing in that they consistently fail in operant tasks that require them to combine central nervous system reward information with visual and peripheral knowledge of the location of their arms. Wells claimed that in order to filter and integrate an abundance of multisensory inputs that might inform the animal of the position of a single arm, octopuses would need an exceptional computing mechanism, and "There is no evidence that such a system exists in Octopus, or in any other soft bodied animal." Recent electrophysiological experiments, which found no clear somatotopic organization in the higher motor centers, support this claim. We developed a three-choice maze that required an octopus to use a single arm to reach a visually marked goal compartment. Using this operant task, we show for the first time that Octopus vulgaris is capable of guiding a single arm in a complex movement to a location. Thus, we claim that octopuses can combine peripheral arm location information with visual input to control goal-directed complex movements. Copyright © 2011 Elsevier Ltd. All rights reserved.

  19. Early Australian experience in robotic sleeve gastrectomy: a single site series.

    PubMed

    Silverman, Candice D; Ghusn, Michael A

    2017-05-01

    The use of robotic platforms in bariatric surgery has recently gained relevance. With an increased use of this technology come concerns regarding learning curve effects during the initial implementation phase. The sleeve gastrectomy though may represent an ideal training procedure for introducing the robot into bariatric surgical practice. The present review of the first 10 consecutive robotic sleeve gastrectomy procedures performed in an Australian bariatric programme by a single surgeon describes the evolution of the technique, learning curve and initial patient outcomes. Between 2014 and 2015, robotic sleeve gastrectomies were performed as primary and revisional procedures by a consistent surgeon-assistant team. Technique evolution and theatre set-up were documented. Patient demographics, operative time (robot docking and total operation time), additional operative procedures performed, operative and post-operative complications at 1, 3 and 6 months post-procedure and weight loss achieved at 6 months were retrospectively reviewed from a prospectively maintained database. Ten robotic sleeve gastrectomies were performed without significant operative complications. One patient was treated as an outpatient with oral antibiotics for a superficial wound infection. The median total operative time was 123 min (interquartile range (IQR) 108.8-142.5), with a median incision to docking time of 19 min (IQR 15.0-31.8). Length of stay in hospital was 2-3 days. Median excess weight loss achieved at 6 months was 50% (IQR 33.9-66.5). This study describes a method of safely introducing the da Vinci robot into bariatric surgical practice. © 2016 Royal Australasian College of Surgeons.

  20. Development of the Lens Antenna Deployment Demonstration (LADD) shuttle-attached flight experiment

    NASA Technical Reports Server (NTRS)

    Hill, H.; Johnston, D.; Frauenberger, H.

    1986-01-01

    The primary objective of the LADD Program is to develop a technology demonstration test article that can be used for both ground and flight tests to demonstrate the structural and mechanical feasibility and reliability of the single-axis roll-out space based radar (SBR) approach. As designed, the LADD will essentially be a generic strucutural experiment which incorporates all critical technology elements of the operational satellite and is applicable to a number of future antenna systems. However, to fully determine its design integrity for meeting the lens flatness and constant geometry requirements in a zero g environment under extreme thermal conditions, the LADD must be space flight tested. By accurately surveying the structure under varying conditions the membrane tolerance-holding capabilities of the structure will be demonstrated. The flight test will provide data to verify analytical tools used to predict thermal and structural behavior. Most important, the experiment will provide an initial indication of structural damping in a zero g vacuum environment. The recently completed Solar Array Flight Experiment (SAFE) showed orbital damping greater than that experienced during ground testing. From the experience and the information obtained from LADD it is hoped that designs can be confidently extrapolated to operational satellites with apertures in the 20 m by 60 m size range.

  1. Flow reversal power limit for the HFBR

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cheng, Lap Y.; Tichler, P.R.

    The High Flux Beam Reactor (HFBR) undergoes a buoyancy-driven reversal of flow in the reactor core following certain postulated accidents. Uncertainties about the afterheat removal capability during the flow reversal has limited the reactor operating power to 30 MW. An experimental and analytical program to address these uncertainties is described in this report. The experiments were single channel flow reversal tests under a range of conditions. The analytical phase involved simulations of the tests to benchmark the physical models and development of a criterion for dryout. The criterion is then used in simulations of reactor accidents to determine a safemore » operating power level. It is concluded that the limit on the HFBR operating power with respect to the issue of flow reversal is in excess of 60 MW.« less

  2. [The evaluation and prognosis of the psychophysiological status of a human operator].

    PubMed

    Sukhov, A E; Chaĭchenko, G M

    1989-01-01

    In experiments on 56 healthy subjects (18-20 years old) the quality of their activity was determined during compensatory watching the mark at complicating regimes of work. Depending on the difficulty of the task five groups of subjects were singled out with optimum working capacity in one of four working conditions: normal, ordinary and strenuous work, model of stress situation. It is established that the change of the number of significant correlative connections between main parameters of psychophysiological state of man-operator reflects the condition of his functional systems. On the basis of computation of total range of organization values of both R-R intervals of the ECG and duration of expiration, the success of the man-operator work in complex conditions of activity is predicted.

  3. Context Influences Holistic Processing of Non-face Objects in the Composite Task

    PubMed Central

    Richler, Jennifer J.; Bukach, Cindy M.; Gauthier, Isabel

    2013-01-01

    We explore whether holistic-like effects can be observed for non-face objects in novices as a result of the task context. We measure contextually-induced congruency effects for novel objects (Greebles) in a sequential matching selective attention task (composite task). When format at study was blocked, congruency effects were observed for study-misaligned, but not study-aligned, conditions (Experiment 1). However, congruency effects were observed in all conditions when study formats were randomized (Experiment 2), revealing that the presence of certain trial types (study-misaligned) in an experiment can induce congruency effects. In a dual task, a congruency effect for Greebles was induced in trials where a face was first encoded, only if it was aligned (Experiment 3). Thus, congruency effects can be induced by context that operates at the scale of the entire experiment or within a single trial. Implications for using the composite task to measure holistic processing are discussed. PMID:19304644

  4. BFPTool: a software tool for analysis of Biomembrane Force Probe experiments.

    PubMed

    Šmít, Daniel; Fouquet, Coralie; Doulazmi, Mohamed; Pincet, Frédéric; Trembleau, Alain; Zapotocky, Martin

    2017-01-01

    The Biomembrane Force Probe is an approachable experimental technique commonly used for single-molecule force spectroscopy and experiments on biological interfaces. The technique operates in the range of forces from 0.1 pN to 1000 pN. Experiments are typically repeated many times, conditions are often not optimal, the captured video can be unstable and lose focus; this makes efficient analysis challenging, while out-of-the-box non-proprietary solutions are not freely available. This dedicated tool was developed to integrate and simplify the image processing and analysis of videomicroscopy recordings from BFP experiments. A novel processing feature, allowing the tracking of the pipette, was incorporated to address a limitation of preceding methods. Emphasis was placed on versatility and comprehensible user interface implemented in a graphical form. An integrated analytical tool was implemented to provide a faster, simpler and more convenient way to process and analyse BFP experiments.

  5. Homogeneous Freezing of Water Droplets and its Dependence on Droplet Size

    NASA Astrophysics Data System (ADS)

    Schmitt, Thea; Möhler, Ottmar; Höhler, Kristina; Leisner, Thomas

    2014-05-01

    The formulation and parameterisation of microphysical processes in tropospheric clouds, such as phase transitions, is still a challenge for weather and climate models. This includes the homogeneous freezing of supercooled water droplets, since this is an important process in deep convective systems, where almost pure water droplets may stay liquid until homogeneous freezing occurs at temperatures around 238 K. Though the homogeneous ice nucleation in supercooled water is considered to be well understood, recent laboratory experiments with typical cloud droplet sizes showed one to two orders of magnitude smaller nucleation rate coefficients than previous literature results, including earlier results from experiments with single levitated water droplets and from cloud simulation experiments at the AIDA (Aerosol Interaction and Dynamics in the Atmosphere) facility. This motivated us to re-analyse homogeneous droplet freezing experiments conducted during the previous years at the AIDA cloud chamber. This cloud chamber has a volume of 84m3 and operates under atmospherically relevant conditions within wide ranges of temperature, pressure and humidity, whereby investigations of both tropospheric mixed-phase clouds and cirrus clouds can be realised. By controlled adiabatic expansions, the ascent of an air parcel in the troposphere can be simulated. According to our new results and their comparison to the results from single levitated droplet experiments, the homogeneous freezing of water droplets seems to be a volume-dependent process, at least for droplets as small as a few micrometers in diameter. A contribution of surface induced freezing can be ruled out, in agreement to previous conclusions from the single droplet experiments. The obtained volume nucleation rate coefficients are in good agreement, within error bars, with some previous literature data, including our own results from earlier AIDA experiments, but they do not agree with recently published lower volume nucleation rate coefficients. This contribution will show the results from the re-analysis of AIDA homogeneous freezing experiments with pure water droplets and will discuss the comparison to the literature data.

  6. Recent developments in high average power driver technology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Prestwich, K.R.; Buttram, M.T.; Rohwein, G.J>

    1979-01-01

    Inertial confinement fusion (ICF) reactors will require driver systems operating with tens to hundreds of megawatts of average power. The pulse power technology that will be required to build such drivers is in a primitive state of development. Recent developments in repetitive pulse power are discussed. A high-voltage transformer has been developed and operated at 3 MV in a single pulse experiment and is being tested at 1.5 MV, 5 kj and 10 pps. A low-loss, 1 MV, 10 kj, 10 pps Marx generator is being tested. Test results from gas-dynamic spark gaps that operate both in the 100 kVmore » and 700 kV range are reported. A 250 kV, 1.5 kA/cm/sup 2/, 30 ns electron beam diode has operated stably for 1.6 x 10/sup 5/ pulses.« less

  7. Pairing induced superconductivity in holography

    NASA Astrophysics Data System (ADS)

    Bagrov, Andrey; Meszena, Balazs; Schalm, Koenraad

    2014-09-01

    We study pairing induced superconductivity in large N strongly coupled systems at finite density using holography. In the weakly coupled dual gravitational theory the mechanism is conventional BCS theory. An IR hard wall cut-off is included to ensure that we can controllably address the dynamics of a single confined Fermi surface. We address in detail the interplay between the scalar order parameter field and fermion pairing. Adding an explicitly dynamical scalar operator with the same quantum numbers as the fermion-pair, the theory experiences a BCS/BEC crossover controlled by the relative scaling dimensions. We find the novel result that this BCS/BEC crossover exposes resonances in the canonical expectation value of the scalar operator. This occurs not only when the scaling dimension is degenerate with the Cooper pair, but also with that of higher derivative paired operators. We speculate that a proper definition of the order parameter which takes mixing with these operators into account stays finite nevertheless.

  8. Evaluation of the flame propagation within an SI engine using flame imaging and LES

    NASA Astrophysics Data System (ADS)

    He, Chao; Kuenne, Guido; Yildar, Esra; van Oijen, Jeroen; di Mare, Francesca; Sadiki, Amsini; Ding, Carl-Philipp; Baum, Elias; Peterson, Brian; Böhm, Benjamin; Janicka, Johannes

    2017-11-01

    This work shows experiments and simulations of the fired operation of a spark ignition engine with port-fuelled injection. The test rig considered is an optically accessible single cylinder engine specifically designed at TU Darmstadt for the detailed investigation of in-cylinder processes and model validation. The engine was operated under lean conditions using iso-octane as a substitute for gasoline. Experiments have been conducted to provide a sound database of the combustion process. A planar flame imaging technique has been applied within the swirl- and tumble-planes to provide statistical information on the combustion process to complement a pressure-based comparison between simulation and experiments. This data is then analysed and used to assess the large eddy simulation performed within this work. For the simulation, the engine code KIVA has been extended by the dynamically thickened flame model combined with chemistry reduction by means of pressure dependent tabulation. Sixty cycles have been simulated to perform a statistical evaluation. Based on a detailed comparison with the experimental data, a systematic study has been conducted to obtain insight into the most crucial modelling uncertainties.

  9. Evaluation of platelet aggregability during left ventricular bypass using a MedTech MagLev VAD in a series of chronic calf experiments.

    PubMed

    Kimura, Taro; Yokoyama, Yoshimasa; Sakota, Daisuke; Nagaoka, Eiki; Kitao, Takashi; Takakuda, Kazuo; Takatani, Setsuo

    2013-03-01

    The impact of continuous flow left ventricular assist device (LVAD) pumping on platelet aggregation was investigated in animal experiments utilizing six calves. A single-use MagLev centrifugal blood pump, MedTech MagLev, was used to bypass the calves' hearts from the left atrium to the descending aorta at a flow rate of 50 ml/kg/min. The LVAD's impact on blood coagulation activities was evaluated based on the platelet aggregability, which was measured with a turbidimetric assay method during the preoperative, operative, and postoperative periods. Heparin and warfarin were used for anticoagulation, while aspirin was used for the antiplatelet therapy. A decrease in platelet aggregation immediately after the pump started was observed in the cases of successful long-term pump operation, while the absence of such a decrease might have caused coagulation-related complications to terminate the experiments. Thus, the platelet aggregability was found to be significantly affected by the pump, and its initial trend may be related to the long-term outcome of the mechanical circulatory support.

  10. A versatile system for the rapid collection, handling and graphics analysis of multidimensional data

    NASA Astrophysics Data System (ADS)

    O'Brien, P. M.; Moloney, G.; O'Connor, A.; Legge, G. J. F.

    1993-05-01

    The aim of this work was to provide a versatile system for handling multiparameter data that may arise from a variety of experiments — nuclear, AMS, microprobe elemental analysis, 3D microtomography etc. Some of the most demanding requirements arise in the application of microprobes to quantitative elemental mapping and to microtomography. A system to handle data from such experiments had been under continuous development and use at MARC for the past 15 years. It has now been made adaptable to the needs of multiparameter (or single parameter) experiments in general. The original system has been rewritten, greatly expanded and made much more powerful and faster, by use of modern computer technology — a VME bus computer with a real time operating system and a RISC workstation running Unix and the X Window system. This provides the necessary (i) power, speed and versatility, (ii) expansion and updating capabilities (iii) standardisation and adaptability, (iv) coherent modular programming structures, (v) ability to interface to other programs and (vi) transparent operation with several levels, involving the use of menus, programmed function keys and powerful macro programming facilities.

  11. Long term performance studies of large oil-free bakelite resistive plate chamber

    NASA Astrophysics Data System (ADS)

    Ganai, R.; Roy, A.; Shiroya, M. K.; Agarwal, K.; Ahammed, Z.; Choudhury, S.; Chattopadhyay, S.

    2016-09-01

    Several high energy physics and neutrino physics experiments worldwide require large-size RPCs to cover wide acceptances. The muon tracking systems in the Iron calorimeter (ICAL) experiment in the India based Neutrino Observatory (INO), India and the near detector in Deep Underground Neutrino Experiment (DUNE) at Fermilab are two such examples. A single gap bakelite RPC of dimension 240 cm × 120 cm, with gas gap of 0.2 cm, has been built and tested at Variable Energy Cyclotron Centre, Kolkata, using indigenous materials procured from the local market. No additional lubricant, like oil has been used on the electrode surfaces for smoothening. The chamber is in operation for > 365 days. We have tested the chamber for its long term operation. The leakage current, bulk resistivity, efficiency, noise rate and time resolution of the chamber have been found to be quite stable during the testing peroid. It has shown an efficiency > 95% with an average time resolution of ~ 0.83 ns at the point of measurement at ~ 8700 V throughout the testing period. Details of the long term performance of the chamber have been discussed.

  12. DCE - PS Linteris in front of rack

    NASA Image and Video Library

    2016-08-12

    STS083-312-017 (4-8 April 1997) --- Payload specialist Gregory T. Linteris sets up a 35mm camera, one of three photographic/recording systems on the Drop Combustion Experiment (DCE) Apparatus. DCE is an enclosed chamber in which Helium-Oxygen fuel mixtures are injected and burned as single droplets. Combustion of fuel droplets is an important part of many operations, home heating, power production by gas turbines and combustion of gasoline in an automobile engine.

  13. Charter and Direct Run Schools of the Recovery School District (RSD) and Orleans Parish School Board (OPSB) Comparison of High Stakes Tests and Dropout Rates

    ERIC Educational Resources Information Center

    Andry, Beverly Guillory

    2011-01-01

    The city of New Orleans has embarked on an historic experiment reinventing its schools--once considered among the worst in the country--from a centralized, single district model of education to a two district model in which both the Recovery School District (RSD) and the preexisting Orleans Parish School Board (OPSB) both operate direct run and…

  14. Solo-Surgeon Single-Port Laparoscopic Anterior Resection for Sigmoid Colon Cancer: Comparative Study.

    PubMed

    Choi, Byung Jo; Jeong, Won Jun; Kim, Say-June; Lee, Sang Chul

    2018-03-01

    To report our experience with solo-surgeon, single-port laparoscopic anterior resection (solo SPAR) for sigmoid colon cancer. Data from sigmoid colon cancer patients who underwent anterior resections (ARs) using the single-port, solo surgery technique (n = 31) or the conventional single-port laparoscopic technique (n = 45), between January 2011 and July 2016, were retrospectively analyzed. In the solo surgeries, making the transumbilical incision into the peritoneal cavity was facilitated through the use of a self-retaining retractor system. After establishing a single port through the umbilicus, an adjustable mechanical camera holder replaced the human scope assistant. Patient and tumor characteristics and operative, pathologic, and postoperative outcomes were compared. The operative times and estimated blood losses were similar for the patients in both treatment groups. In addition, most of the postoperative variables were comparable between the two groups, including postoperative complications and hospital stays. In the solo SPAR group, comparable lymph nodes were attained, and sufficient proximal and distal cut margins were obtained. The difference in the proximal cut margin significantly favored the solo SPAR, compared with the conventional AR group (P = .000). This study shows that solo SPAR, using a passive camera system, is safe and feasible for use in sigmoid colon cancer surgery, if performed by an experienced laparoscopic surgeon. In addition to reducing the need for a surgical assistant, the oncologic requirements, including adequate margins and sufficient lymph node harvesting, could be fulfilled. Further evaluations, including prospective randomized studies, are warranted.

  15. Towards constructing multi-bit binary adder based on Belousov-Zhabotinsky reaction

    NASA Astrophysics Data System (ADS)

    Zhang, Guo-Mao; Wong, Ieong; Chou, Meng-Ta; Zhao, Xin

    2012-04-01

    It has been proposed that the spatial excitable media can perform a wide range of computational operations, from image processing, to path planning, to logical and arithmetic computations. The realizations in the field of chemical logical and arithmetic computations are mainly concerned with single simple logical functions in experiments. In this study, based on Belousov-Zhabotinsky reaction, we performed simulations toward the realization of a more complex operation, the binary adder. Combining with some of the existing functional structures that have been verified experimentally, we designed a planar geometrical binary adder chemical device. Through numerical simulations, we first demonstrated that the device can implement the function of a single-bit full binary adder. Then we show that the binary adder units can be further extended in plane, and coupled together to realize a two-bit, or even multi-bit binary adder. The realization of chemical adders can guide the constructions of other sophisticated arithmetic functions, ultimately leading to the implementation of chemical computer and other intelligent systems.

  16. Single pilot IFR operating problems determined from accidental data analysis

    NASA Technical Reports Server (NTRS)

    Forsyth, D. L.; Shaughnessy, J. D.

    1978-01-01

    The accident reports examined were restricted to instrument rated pilots flying in IFR weather. A brief examination was made of accidents which occurred during all phases of flight and which were due to all causes. A detailed examination was made of those accidents which involved a single pilot which occurred during the landing phases of flight, and were due to pilot error. Problem areas found include: (1) landing phase operations especially final approach, (2) pilot weather briefings, (3) night approaches in low IFR weather, (4) below minimum approaches, (5) aircraft icing, (6) imprecise navigation, (7) descending below minimum IFR altitudes, (8) fuel mismanagement, (9) pilot overconfidence, and (10) high pilot workload especially in twins. Some suggested areas of research included: (1) low cost deicing systems, (2) standardized navigation displays, (3) low cost low-altitude warning systems, (4) improved fuel management systems, (5) improved ATC communications, (6) more effective pilot training and experience acquisition methods, and (7) better weather data dissemination techniques.

  17. Resonantly diode laser pumped 1.6-μm Er:YAG laser

    NASA Astrophysics Data System (ADS)

    Garbuzov, Dmitri; Kudryashov, Igor; Dubinskii, Mark

    2005-06-01

    We report what is believed to be the first demonstration of direct resonant diode pumping of a 1.6-mm Er3+-doped bulk solid-state laser (DPSSL). The most of the results is obtained with pumping Er:YAG by the single mode diode laser packaged in fibered modules. The fibered modules, emitting at 1470 nm and 1530 nm wavelength with and without fiber grating (FBG) stabilization, have been used in pumping experiments. The very first results on high power DPSSL operation achieved with diode array pumping also will be presented. The highest absorbed photon conversion efficiency of 26% has been obtained for Er:YAG DPSSL using the 1470-nm single-mode module. Analysis of the DPSSL input-output characteristics suggests that the obtained slope efficiency can be increased at least up to 40% through the reduction of intracavity losses and pumping efficiency improvement. Diode pumped SSL (DPSSL) operates at a wavelength of 1617 nm and 1645 nm.

  18. Insight into the da Vinci® Xi - technical notes for single-docking left-sided colorectal procedures.

    PubMed

    Ngu, James Chi-Yong; Sim, Sarah; Yusof, Sulaiman; Ng, Chee-Yung; Wong, Andrew Siang-Yih

    2017-12-01

    The adoption of robot-assisted laparoscopic colorectal surgery has been hampered by issues with docking, operative duration, technical difficulties in multi-quadrant access, and cost. The da Vinci® Xi has been designed to overcome some of these limitations. We describe our experience with the system and offer technical insights to its application in left-sided colorectal procedures. Our initial series of left-sided robotic colorectal procedures was evaluated. Patient demographics and operative outcomes were recorded prospectively using a predefined database. Between March 2015 and April 2016, 54 cases of robot-assisted laparoscopic left-sided colorectal procedures were successfully completed with no cases of conversion. The majority were low anterior resections for colorectal malignancies. Using the da Vinci® Xi Surgical System, multi-quadrant surgery involving dissection from the splenic flexure to the pelvis was possible without redocking. The da Vinci® Xi simplifies the docking procedure and makes single-docking feasible for multi-quadrant left-sided colorectal procedures. Copyright © 2016 John Wiley & Sons, Ltd.

  19. A compact source for bunches of singly charged atomic ions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Murböck, T.; Birkl, G.; Schmidt, S.

    2016-04-15

    We have built, operated, and characterized a compact ion source for low-energy bunches of singly charged atomic ions in a vacuum beam line. It is based on atomic evaporation from an electrically heated oven and ionization by electron impact from a heated filament inside a grid-based ionization volume. An adjacent electrode arrangement is used for ion extraction and focusing by applying positive high-voltage pulses to the grid. The method is particularly suited for experimental environments which require low electromagnetic noise. It has proven simple yet reliable and has been used to produce μs-bunches of up to 10{sup 6} Mg{sup +}more » ions at a repetition rate of 1 Hz. We present the concept, setup and characterizing measurements. The instrument has been operated in the framework of the SpecTrap experiment at the HITRAP facility at GSI/FAIR to provide Mg{sup +} ions for sympathetic cooling of highly charged ions by laser-cooled {sup 24}Mg{sup +}.« less

  20. Single port VATS: recent developments in Asia.

    PubMed

    Yu, Peter S Y; Capili, Freddie; Ng, Calvin S H

    2016-03-01

    Single port video-assisted thoracic surgery (VATS) is the most recent evolution in minimally invasive thoracic surgery. With increasing global popularity, the single port VATS approach has been adopted by experienced thoracic surgeons in many Asian countries. From initial experience of single port VATS lobectomy to the more complex sleeve resection procedures now forming part of daily practice in some Asia institutes, the region has been the proving ground for single port VATS approaches' feasibility and safety. In addition, certain technical refinements in single port VATS lung resection and lymph node dissection have also sprung from Asia. Novel equipment designed to facilitate single port VATS allowing further reduce access trauma are being realized by the partnership between surgeons and the industries. Advanced thoracoscopes and staplers that are narrower and more maneuverable are particularly important in the smaller habitus of patients from Asia. These and similar new generation equipment are being applied to single port VATS in novel ways. As dedicated thoracic surgeons in the region continue to striving for excellence, innovative ideas in single incision access including subxiphoid and embryonic natural-orifice transluminal endoscopic surgery (e-NOTES) have been explored. Adjunct techniques and technology used in association with single port VATS such as non-intubated surgery, hybrid operating room image guidance and electromagnetic navigational bronchoscopy are all in rapid development in Asia.

  1. Laparoendoscopic single-site Heller myotomy with anterior fundoplication for achalasia.

    PubMed

    Barry, Linda; Ross, Sharona; Dahal, Sujat; Morton, Connor; Okpaleke, Chinyere; Rosas, Melissa; Rosemurgy, Alexander S

    2011-06-01

    Laparoendoscopic single-site (LESS) surgery is beginning to include advanced laparoscopic operations such as Heller myotomy with anterior fundoplication. However, the efficacy of LESS Heller myotomy has not been established. This study aimed to evaluate the authors' initial experience with LESS Heller myotomy for achalasia. Transumbilical LESS Heller myotomy with concomitant anterior fundoplication for achalasia was undertaken for 66 patients after October 2007. Outcomes including operative time, complications, and length of hospital stay were recorded and compared with those for an earlier contiguous group of 66 consecutive patients undergoing conventional multi-incision laparoscopic Heller myotomy with anterior fundoplication. Symptoms before and after myotomy were scored by the patients using a Likert scale ranging from 0 (never/not severe) to 10 (always/very severe). Data were analyzed using the Mann-Whitney U test, the Wilcoxon matched-pairs test, and Fisher's exact test where appropriate. Patients undergoing LESS Heller myotomy were similar to those undergoing conventional laparoscopic Heller myotomy in gender, age, body mass index (BMI), blood loss, and length of hospital stay. However, the patients undergoing LESS Heller myotomies had operations of significantly longer duration (median, 117 vs. 93 min with the conventional laparoscopic approach) (p<0.003). For 11 patients (16%) undergoing LESS Heller myotomy, additional ports/incisions were required. No patients were converted to "open" operations, and no patients had procedure-specific complications. Symptom reduction was dramatic and satisfying after both LESS and conventional laparoscopic myotomy with fundoplication. The symptom reduction was similar with the two procedures. The LESS approach left no apparent umbilical scar. Heller myotomy with anterior fundoplication effectively treats achalasia. The findings showed LESS Heller myotomy with anterior fundoplication to be feasible, safe, and efficacious. Although the LESS approach increases operative time, it does not increase procedure-related morbidity or hospital length of stay and avoids apparent umbilical scarring. Laparoendoscopic single-site surgery represents a paradigm shift to more minimally invasive surgery and is applicable to advanced laparoscopic operations such as Heller myotomy and anterior fundoplication.

  2. LANDSAT-D MSS/TM tuned orbital jitter analysis model LDS900

    NASA Technical Reports Server (NTRS)

    Pollak, T. E.

    1981-01-01

    The final LANDSAT-D orbital dynamic math model (LSD900), comprised of all test validated substructures, was used to evaluate the jitter response of the MSS/TM experiments. A dynamic forced response analysis was performed at both the MSS and TM locations on all structural modes considered (thru 200 Hz). The analysis determined the roll angular response of the MSS/TM experiments to improve excitation generated by component operation. Cross axis and cross experiment responses were also calculated. The excitations were analytically represented by seven and nine term Fourier series approximations, for the MSS and TM experiment respectively, which enabled linear harmonic solution techniques to be applied to response calculations. Single worst case jitter was estimated by variations of the eigenvalue spectrum of model LSD 900. The probability of any worst case mode occurrence was investigated.

  3. Microcontroller-based binary integrator for millimeter-wave radar experiments.

    PubMed

    Eskelinen, Pekka; Ruoskanen, Jukka; Peltonen, Jouni

    2010-05-01

    An easily on-site reconfigurable multiple binary integrator for millimeter radar experiments has been constructed of static random access memories, an eight bit microcontroller, and high speed video operational amplifiers. The design uses a raw comparator path and two adjustable m-out-of-n chains in a wired-OR configuration. Standard high speed memories allow the use of pulse widths below 100 ns. For eight pulse repetition intervals it gives a maximum improvement of 6.6 dB for stationary low-level target echoes. The doubled configuration enhances the capability against fluctuating targets. Because of the raw comparator path, also single return pulses of relatively high amplitude are processed.

  4. Life sciences flight experiments program mission science requirements document. The first life sciences dedicated Spacelab mission, part 1

    NASA Technical Reports Server (NTRS)

    Rummel, J. A.

    1982-01-01

    The Mission Science Requirements Document (MSRD) for the First Dedicated Life Sciences Mission (LS-1) represents the culmination of thousands of hours of experiment selection, and science requirement definition activities. NASA life sciences has never before attempted to integrate, both scientifically and operationally, a single mission dedicated to life sciences research, and the complexity of the planning required for such an endeavor should be apparent. This set of requirements completes the first phase of a continual process which will attempt to optimize (within available programmatic and mission resources) the science accomplished on this mission.

  5. 75 FR 64683 - Liability for Termination of Single-Employer Plans; Treatment of Substantial Cessation of Operations

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-20

    ... Termination of Single-Employer Plans; Treatment of Substantial Cessation of Operations AGENCY: Pension Benefit... cessations of operations by employers that maintain single-employer plans. DATES: Comments must be submitted... 4062(e), which provides for reporting of and liability for certain substantial cessations of operations...

  6. High Efficiency End-Pumped Ho:Tm:YLF Disk Amplifier

    NASA Technical Reports Server (NTRS)

    Yu, Jirong; Singh, Upendra N.; Petros, Mulugeta; Axenson, Theresa J.; Barnes, Norman P.

    1999-01-01

    Space based coherent lidar for global wind measurement requires an all solid state laser system with high energy, high efficiency and narrow linewidth that operates in the eye safe region. A Q-switched, diode pumped Ho:Tm:YLF 2 micrometer laser with output energy of as much as 125 mJ at 6 Hz with an optical-to-optical efficiency of 3% has been reported. Single frequency operation of the laser was achieved by injection seeding. The design of this laser is being incorporated into NASA's SPARCLE (SPAce Readiness Coherent Lidar Experiment) wind lidar mission. Laser output energy ranging from 500 mJ to 2 J is required for an operational space coherent lidar. We previously developed a high energy Ho:Tm:YLF master oscillator and side pumped power amplifier system and demonstrated a 600-mJ single frequency pulse at a repetition rate of 10 Hz. Although the output energy is high, the optical-to-optical efficiency is only about 2%. Designing a high energy, highly efficient, conductively cooled 2-micrometer laser remains a challenge. In this paper, the preliminary result of an end-pumped amplifier that has a potential to provide a factor 3 of improvement in the system efficiency is reported.

  7. Global identification of stochastic dynamical systems under different pseudo-static operating conditions: The functionally pooled ARMAX case

    NASA Astrophysics Data System (ADS)

    Sakellariou, J. S.; Fassois, S. D.

    2017-01-01

    The identification of a single global model for a stochastic dynamical system operating under various conditions is considered. Each operating condition is assumed to have a pseudo-static effect on the dynamics and be characterized by a single measurable scheduling variable. Identification is accomplished within a recently introduced Functionally Pooled (FP) framework, which offers a number of advantages over Linear Parameter Varying (LPV) identification techniques. The focus of the work is on the extension of the framework to include the important FP-ARMAX model case. Compared to their simpler FP-ARX counterparts, FP-ARMAX models are much more general and offer improved flexibility in describing various types of stochastic noise, but at the same time lead to a more complicated, non-quadratic, estimation problem. Prediction Error (PE), Maximum Likelihood (ML), and multi-stage estimation methods are postulated, and the PE estimator optimality, in terms of consistency and asymptotic efficiency, is analytically established. The postulated estimators are numerically assessed via Monte Carlo experiments, while the effectiveness of the approach and its superiority over its FP-ARX counterpart are demonstrated via an application case study pertaining to simulated railway vehicle suspension dynamics under various mass loading conditions.

  8. Development of ion source with a washer gun for pulsed neutral beam injection.

    PubMed

    Asai, T; Yamaguchi, N; Kajiya, H; Takahashi, T; Imanaka, H; Takase, Y; Ono, Y; Sato, K N

    2008-06-01

    A new type of economical neutral beam source has been developed by using a single washer gun, pulsed operation, and a simple electrode system. We replaced the conventional hot filaments for arc-discharge-type plasma formation with a single stainless-steel washer gun, eliminating the entire dc power supply for the filaments and the cooling system for the electrodes. Our initial experiments revealed successful beam extraction up to 10 kV and 8.6 A, based on spatial profile measurements of density and temperature in the plasma source. The system also shows the potential to control the beam profile by controlling the plasma parameters in the ion accumulation chamber.

  9. VERAIn

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Simunovic, Srdjan

    2015-02-16

    CASL's modeling and simulation technology, the Virtual Environment for Reactor Applications (VERA), incorporates coupled physics and science-based models, state-of-the-art numerical methods, modern computational science, integrated uncertainty quantification (UQ) and validation against data from operating pressurized water reactors (PWRs), single-effect experiments, and integral tests. The computational simulation component of VERA is the VERA Core Simulator (VERA-CS). The core simulator is the specific collection of multi-physics computer codes used to model and deplete a LWR core over multiple cycles. The core simulator has a single common input file that drives all of the different physics codes. The parser code, VERAIn, converts VERAmore » Input into an XML file that is used as input to different VERA codes.« less

  10. Pellet injection research on the HT-6M and HT-7 tokamaks

    NASA Astrophysics Data System (ADS)

    Yang, Yu; Bao, Yi; Li, Jiangang; Gu, Xuemao; He, Yexi

    1999-11-01

    A multishot in situ pellet injection system has been constructed in the Institute of Plasma Physics. Single- and multi-pellet injection experiments were performed on the HT-6M and superconducting HT-7 tokamaks. The system proved to be convenient and reliable to operate. Pellets were fired into ohmically and LHCD and ICRF heated plasmas. Single pellet injection in ohmic discharge was found to increase the central density of HT-7 by about one half, while two pellet injection increased the central density in a step-like fashion by one half with each shot. Peaking of the electron density profile and a hollow electron temperature profile were obtained.

  11. Neural networks for tracking of unknown SISO discrete-time nonlinear dynamic systems.

    PubMed

    Aftab, Muhammad Saleheen; Shafiq, Muhammad

    2015-11-01

    This article presents a Lyapunov function based neural network tracking (LNT) strategy for single-input, single-output (SISO) discrete-time nonlinear dynamic systems. The proposed LNT architecture is composed of two feedforward neural networks operating as controller and estimator. A Lyapunov function based back propagation learning algorithm is used for online adjustment of the controller and estimator parameters. The controller and estimator error convergence and closed-loop system stability analysis is performed by Lyapunov stability theory. Moreover, two simulation examples and one real-time experiment are investigated as case studies. The achieved results successfully validate the controller performance. Copyright © 2015 ISA. Published by Elsevier Ltd. All rights reserved.

  12. Single incision laparoscopic surgery (SILS) in gynaecology: feasibility and operative outcomes.

    PubMed

    Behnia-Willison, Fariba; Foroughinia, Leila; Sina, Maryam; McChesney, Phil

    2012-08-01

    Single incision laparoscopic surgery (SILS) represents the latest advancement in minimally invasive surgery, combining the benefits of conventional laparoscopic surgery, such as less pain and faster recovery, with improved cosmesis. Although the successful use of this technique is well reported in general surgery and urology, there is a lack of studies on SILS in gynaecology. To evaluate the feasibility, safety, cosmesis and outcome of SILS in gynaecology. A prospective case series analysis of 105 women scheduled to undergo surgery by SILS from August 2010 to November 2011. Intra-operative data such as operative time, estimated blood loss, complications, additional ports and hospital stay were collected. Post-operative pain and cosmetic outcomes (scar size) were also recorded. Out of 105 women, SILS was performed for 84 (60 excisions of endometriosis, 13 divisions of adhesions, five hysterectomies, two mesh sacrohysteropexies and four ovarian cystectomies). SILS was not undertaken for 21 women because of a number of factors, including the lack of required equipment (eg bariatric scope, SILS port, roticulating instruments and diathermy leads). Four women required insertion of additional ports because of surgical difficulties. One intra-operative (uterine perforation) and seven post-operative complications (six wound infections and one vault haematoma) occurred. Mean operation times were as follows: mesh sacrohysteropexy - 60 min, excision of endometriosis - 55 min, hysterectomy - 150 min, laparoscopic division of adhesions - 62 min and ovarian cystectomy - 40 min. Our experience shows that SILS is a feasible and safe technique for the surgical management of various gynaecological conditions. Satisfaction is high because of improved cosmesis and reduced analgesic requirements post-operatively. © 2012 The Authors ANZJOG © 2012 The Royal Australian and New Zealand College of Obstetricians and Gynaecologists.

  13. Advanced helicopter cockpit and control configurations for helicopter combat missions

    NASA Technical Reports Server (NTRS)

    Haworth, Loran A.; Atencio, Adolph, Jr.; Bivens, Courtland; Shively, Robert; Delgado, Daniel

    1987-01-01

    Two piloted simulations were conducted by the U.S. Army Aeroflightdynamics Directorate to evaluate workload and helicopter-handling qualities requirements for single pilot operation in a combat Nap-of-the-Earth environment. The single-pilot advanced cockpit engineering simulation (SPACES) investigations were performed on the NASA Ames Vertical Motion Simulator, using the Advanced Digital Optical Control System control laws and an advanced concepts glass cockpit. The first simulation (SPACES I) compared single pilot to dual crewmember operation for the same flight tasks to determine differences between dual and single ratings, and to discover which control laws enabled adequate single-pilot helicopter operation. The SPACES II simulation concentrated on single-pilot operations and use of control laws thought to be viable candidates for single pilot operations workload. Measures detected significant differences between single-pilot task segments. Control system configurations were task dependent, demonstrating a need for inflight reconfigurable control system to match the optimal control system with the required task.

  14. Comparison of the Operative Outcomes and Learning Curves between Laparoscopic and Robotic Gastrectomy for Gastric Cancer

    PubMed Central

    Huang, Kuo-Hung; Lan, Yuan-Tzu; Fang, Wen-Liang; Chen, Jen-Hao; Lo, Su-Shun; Li, Anna Fen-Yau; Chiou, Shih-Hwa; Wu, Chew-Wun; Shyr, Yi-Ming

    2014-01-01

    Background Minimally invasive surgery, including laparoscopic and robotic gastrectomy, has become more popular in the treatment of gastric cancer. However, few studies have compared the learning curves between laparoscopic and robotic gastrectomy for gastric cancer. Methods Data were prospectively collected between July 2008 and Aug 2014. A total of 145 patients underwent minimally invasive gastrectomy for gastric cancer by a single surgeon, including 73 laparoscopic and 72 robotic gastrectomies. The clinicopathologic characteristics, operative outcomes and learning curves were compared between the two groups. Results Compared with the laparoscopic group, the robotic group was associated with less blood loss and longer operative time. After the surgeon learning curves were overcome for each technique, the operative outcomes became similar between the two groups except longer operative time in the robotic group. After accumulating more cases of robotic gastrectomy, the operative time in the laparoscopic group decreased dramatically. Conclusions After overcoming the learning curves, the operative outcomes became similar between laparoscopic and robotic gastrectomy. The experience of robotic gastrectomy could affect the learning process of laparoscopic gastrectomy. PMID:25360767

  15. Mixing Study in a Multi-dimensional Motion Mixer

    NASA Astrophysics Data System (ADS)

    Shah, R.; Manickam, S. S.; Tomei, J.; Bergman, T. L.; Chaudhuri, B.

    2009-06-01

    Mixing is an important but poorly understood aspect in petrochemical, food, ceramics, fertilizer and pharmaceutical processing and manufacturing. Deliberate mixing of granular solids is an essential operation in the production of industrial powder products usually constituted from different ingredients. The knowledge of particle flow and mixing in a blender is critical to optimize the design and operation. Since performance of the product depends on blend homogeneity, the consequence of variability can be detrimental. A common approach to powder mixing is to use a tumbling blender, which is essentially a hollow vessel horizontally attached to a rotating shaft. This single axis rotary blender is one of the most common batch mixers among in industry, and also finds use in myriad of application as dryers, kilns, coaters, mills and granulators. In most of the rotary mixers the radial convection is faster than axial dispersion transport. This slow dispersive process hinders mixing performance in many blending, drying and coating applications. A double cone mixer is designed and fabricated which rotates around two axes, causing axial mixing competitive to its radial counterpart. Discrete Element Method (DEM) based numerical model is developed to simulate the granular flow within the mixer. Digitally recorded mixing states from experiments are used to fine tune the numerical model. Discrete pocket samplers are also used in the experiments to quantify the characteristics of mixing. A parametric study of the effect of vessel speeds, relative rotational speed (between two axes of rotation), on the granular mixing is investigated by experiments and numerical simulation. Incorporation of dual axis rotation enhances axial mixing by 60 to 85% in comparison to single axis rotation.

  16. Validation of Extended MHD Models using MST RFP Plasmas

    NASA Astrophysics Data System (ADS)

    Jacobson, C. M.; Chapman, B. E.; Craig, D.; McCollam, K. J.; Sovinec, C. R.

    2016-10-01

    Significant effort has been devoted to improvement of computational models used in fusion energy sciences. Rigorous validation of these models is necessary in order to increase confidence in their ability to predict the performance of future devices. MST is a well diagnosed reversed-field pinch (RFP) capable of operation over a wide range of parameters. In particular, the Lundquist number S, a key parameter in resistive magnetohydrodynamics (MHD), can be varied over a wide range and provide substantial overlap with MHD RFP simulations. MST RFP plasmas are simulated using both DEBS, a nonlinear single-fluid visco-resistive MHD code, and NIMROD, a nonlinear extended MHD code, with S ranging from 104 to 5 ×104 for single-fluid runs, with the magnetic Prandtl number Pm = 1 . Experiments with plasma current IP ranging from 60 kA to 500 kA result in S from 4 ×104 to 8 ×106 . Validation metric comparisons are presented, focusing on how magnetic fluctuations b scale with S. Single-fluid NIMROD results give S b - 0.21 , and experiments give S b - 0.28 for the dominant m = 1 , n = 6 mode. Preliminary two-fluid NIMROD results are also presented. Work supported by US DOE.

  17. Machine vision based teleoperation aid

    NASA Technical Reports Server (NTRS)

    Hoff, William A.; Gatrell, Lance B.; Spofford, John R.

    1991-01-01

    When teleoperating a robot using video from a remote camera, it is difficult for the operator to gauge depth and orientation from a single view. In addition, there are situations where a camera mounted for viewing by the teleoperator during a teleoperation task may not be able to see the tool tip, or the viewing angle may not be intuitive (requiring extensive training to reduce the risk of incorrect or dangerous moves by the teleoperator). A machine vision based teleoperator aid is presented which uses the operator's camera view to compute an object's pose (position and orientation), and then overlays onto the operator's screen information on the object's current and desired positions. The operator can choose to display orientation and translation information as graphics and/or text. This aid provides easily assimilated depth and relative orientation information to the teleoperator. The camera may be mounted at any known orientation relative to the tool tip. A preliminary experiment with human operators was conducted and showed that task accuracies were significantly greater with than without this aid.

  18. Continuous data assimilation experiments with the NMC eta model: A GALE IOP 1 case study. [NMC (National Meteorological Center); GALE IOP (Genesis of Atlantic Lows Experiment intensive observing period)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ramamurthy, M.K.; Xu, T.Y.

    1993-11-01

    The current major expansion in observational capability of the National Weather Service is principally in the volume of asynchronous data rather than synchronous observations at the standard synoptic times. Hence, the National Meteorological Center is considering a continuous data assimilation system to replace at some time the intermittent system now used by its regional and global operational models. We describe this system, based on the Newtonian relaxation technique, as developed for the eta model. Experiments are performed for the first intensive observing period of the Genesis of Atlantic Lows Experiment (GALE) in January 1986, when strong upper-level cyclogenesis occurred, withmore » a pronounced tropopause fold but only modest surface development. The GALE level IIIb dataset was used for initializing and updating the model. Issues addressed in the experiments include choice of update variable, number, and length of update segments; need for updating moisture and surface pressure information; nudging along boundaries; and noise control. Assimilation of data from a single level was also studied. Use of a preforecast assimilation cycle was found to eliminate the spinup problem almost entirely. Multiple, shorter assimilation segments produced better forecasts than a single, longer cycle. Updating the mass field was less effective than nudging the wind field but assimilating both was best. Assimilation of moisture data, surprisingly, affected the spinup adversely, but nudging the surface pressure information reduced the spurious pillow effect. Assimilation of single-level information was ineffective unless accompanied by increased vertical coupling, obtained from a control integration. 52 refs., 19 figs., 1 tab.« less

  19. An Intelligent Man-Machine Interface—Multi-Robot Control Adapted for Task Engagement Based on Single-Trial Detectability of P300

    PubMed Central

    Kirchner, Elsa A.; Kim, Su K.; Tabie, Marc; Wöhrle, Hendrik; Maurus, Michael; Kirchner, Frank

    2016-01-01

    Advanced man-machine interfaces (MMIs) are being developed for teleoperating robots at remote and hardly accessible places. Such MMIs make use of a virtual environment and can therefore make the operator immerse him-/herself into the environment of the robot. In this paper, we present our developed MMI for multi-robot control. Our MMI can adapt to changes in task load and task engagement online. Applying our approach of embedded Brain Reading we improve user support and efficiency of interaction. The level of task engagement was inferred from the single-trial detectability of P300-related brain activity that was naturally evoked during interaction. With our approach no secondary task is needed to measure task load. It is based on research results on the single-stimulus paradigm, distribution of brain resources and its effect on the P300 event-related component. It further considers effects of the modulation caused by a delayed reaction time on the P300 component evoked by complex responses to task-relevant messages. We prove our concept using single-trial based machine learning analysis, analysis of averaged event-related potentials and behavioral analysis. As main results we show (1) a significant improvement of runtime needed to perform the interaction tasks compared to a setting in which all subjects could easily perform the tasks. We show that (2) the single-trial detectability of the event-related potential P300 can be used to measure the changes in task load and task engagement during complex interaction while also being sensitive to the level of experience of the operator and (3) can be used to adapt the MMI individually to the different needs of users without increasing total workload. Our online adaptation of the proposed MMI is based on a continuous supervision of the operator's cognitive resources by means of embedded Brain Reading. Operators with different qualifications or capabilities receive only as many tasks as they can perform to avoid mental overload as well as mental underload. PMID:27445742

  20. Conducting Research on the International Space Station Using the EXPRESS Rack Facilities

    NASA Technical Reports Server (NTRS)

    Thompson, Sean W.; Lake, Robert E.

    2013-01-01

    Eight "Expedite the Processing of Experiments to Space Station" (EXPRESS) Rack facilities are located within the International Space Station (ISS) laboratories to provide standard resources and interfaces for the simultaneous and independent operation of multiple experiments within each rack. Each EXPRESS Rack provides eight Middeck Locker Equivalent locations and two drawer locations for powered experiment equipment, also referred to as sub-rack payloads. Payload developers may provide their own structure to occupy the equivalent volume of one, two, or four lockers as a single unit. Resources provided for each location include power (28 Vdc, 0-500 W), command and data handling (Ethernet, RS-422, 5 Vdc discrete, +/- 5 Vdc analog), video (NTSC/RS 170A), and air cooling (0-200 W). Each rack also provides water cooling (500 W) for two locations, one vacuum exhaust interface, and one gaseous nitrogen interface. Standard interfacing cables and hoses are provided on-orbit. One laptop computer is provided with each rack to control the rack and to accommodate payload application software. Four of the racks are equipped with the Active Rack Isolation System to reduce vibration between the ISS and the rack. EXPRESS Racks are operated by the Payload Operations Integration Center at Marshall Space Flight Center and the sub-rack experiments are operated remotely by the investigating organization. Payload Integration Managers serve as a focal to assist organizations developing payloads for an EXPRESS Rack. NASA provides EXPRESS Rack simulator software for payload developers to checkout payload command and data handling at the development site before integrating the payload with the EXPRESS Functional Checkout Unit for an end-to-end test before flight. EXPRESS Racks began supporting investigations onboard ISS on April 24, 2001 and will continue through the life of the ISS.

  1. Conducting Research on the International Space Station using the EXPRESS Rack Facilities

    NASA Technical Reports Server (NTRS)

    Thompson, Sean W.; Lake, Robert E.

    2016-01-01

    Eight "Expedite the Processing of Experiments to Space Station" (EXPRESS) Rack facilities are located within the International Space Station (ISS) laboratories to provide standard resources and interfaces for the simultaneous and independent operation of multiple experiments within each rack. Each EXPRESS Rack provides eight Middeck Locker Equivalent locations and two drawer locations for powered experiment equipment, also referred to as sub-rack payloads. Payload developers may provide their own structure to occupy the equivalent volume of one, two, or four lockers as a single unit. Resources provided for each location include power (28 Vdc, 0-500 W), command and data handling (Ethernet, RS-422, 5 Vdc discrete, +/- 5 Vdc analog), video (NTSC/RS 170A), and air cooling (0-200 W). Each rack also provides water cooling for two locations (500W ea.), one vacuum exhaust interface, and one gaseous nitrogen interface. Standard interfacing cables and hoses are provided on-orbit. One laptop computer is provided with each rack to control the rack and to accommodate payload application software. Four of the racks are equipped with the Active Rack Isolation System to reduce vibration between the ISS and the rack. EXPRESS Racks are operated by the Payload Operations Integration Center at Marshall Space Flight Center and the sub-rack experiments are operated remotely by the investigating organization. Payload Integration Managers serve as a focal to assist organizations developing payloads for an EXPRESS Rack. NASA provides EXPRESS Rack simulator software for payload developers to checkout payload command and data handling at the development site before integrating the payload with the EXPRESS Functional Checkout Unit for an end-to-end test before flight. EXPRESS Racks began supporting investigations onboard ISS on April 24, 2001 and will continue through the life of the ISS.

  2. Cryogen-free superconducting magnet system for multifrequency electron paramagnetic resonance up to 12.1 T

    NASA Astrophysics Data System (ADS)

    Smirnov, Alex I.; Smirnova, Tatyana I.; MacArthur, Ryan L.; Good, Jeremy A.; Hall, Renny

    2006-03-01

    Multifrequency and high field/high frequency (HF) electron paramagnetic resonance (EPR) is a powerful spectroscopy for studying paramagnetic spin systems ranging from organic-free radicals to catalytic paramagnetic metal ion centers in metalloproteins. Typically, HF EPR experiments are carried out at resonant frequencies ν =95-300GHz and this requires magnetic fields of 3.4-10.7T for electronic spins with g ≈2.0. Such fields could be easily achieved with superconducting magnets, but, unlike NMR, these magnets cannot operate in a persistent mode in order to satisfy a wide range of resonant fields required by the experiment. Operating and maintaining conventional passively cooled superconducting magnets in EPR laboratories require frequent transfer of cryogens by trained personnel. Here we describe and characterize a versatile cryogen-free magnet system for HF EPR at magnetic fields up to 12.1T that is suitable for ramping the magnetic field over the entire range, precision scans around the target field, and/or holding the field at the target value. We also demonstrate that in a nonpersistent mode of operation the magnetic field can be stabilized to better than 0.3ppm/h over 15h period by employing a transducer-controlled power supply. Such stability is sufficient for many HF EPR experiments. An important feature of the system is that it is virtually maintenance-free because it is based on a cryogen-free technology and therefore does not require any liquid cryogens (liquid helium or nitrogen) for operation. We believe that actively cooled superconducting magnets are ideally suited for a wide range of HF EPR experiments including studies of spin-labeled nucleic acids and proteins, single-molecule magnets, and metalloproteins.

  3. Single mode, short cavity, Pb-salt diode lasers operating in the 5, 10, and 30-microns spectral regions

    NASA Technical Reports Server (NTRS)

    Linden, K. J.

    1985-01-01

    Pb-salt diode lasers are being used as frequency-tunable infrared sources in high resolution spectroscopy and heterodyne detection applications. Recent advances in short cavity, stripe-geometry laser configurations have led to significant increases in maximum CW operating temperature, single mode operation, and increased single mode tuning range. This paper describes short cavity, stripe geometry lasers operating in the 5, 10, and 30-microns spectral regions, with single mode tuning ranges of over 6/cm.

  4. Coronary reconnection in emergency "conduit operation" for acute type-a aortic dissection with aortic insufficiency: experience with 24 cases.

    PubMed

    Massimo, C G; Presenti, L F; Favi, P P; Duranti, A; Poma, A G; Marranci, P; Modiano, C

    1987-12-01

    Twenty-four cases of acute type-A aortic dissection with aortic valvular insufficiency were treated in our institution by means of an emergency operation in which the aortic valve, ascending aorta, and aortic arch were resected and replaced with a valved conduit that had been lengthened with a tubular Dacron graft. The procedure included the use of deep hypothermia for cerebral protection, as well as extracorporeal circulation. Aortic resection was performed from the aortic valve to the origin of the descending thoracic aorta; the aortic graft was anastomosed proximally to the valve annulus and distally to the descending aorta. The carotid orifices were connected to the side of the graft in a single tissue button. The coronary arteries were then reconnected by means of double venous bypass grafts to the innominate artery, to allow for inclusion of the graft. Within 1 month after operation, four patients died of the consequences of dissection. Six months postoperatively, one patient succumbed to an infarction. Six months to 5 years after operation, the remaining 19 patients are still alive. On the basis of this experience, we believe that acute type-A aortic dissection with aortic valvular insufficiency should be treated during the first hours after the onset of symptoms. The above-described procedure proved effective in the control of bleeding, which is the major risk in emergency operations of this type.

  5. The Super Tuesday Outbreak: Forecast Sensitivities to Single-Moment Microphysics Schemes

    NASA Technical Reports Server (NTRS)

    Molthan, Andrew L.; Case, Jonathan L.; Dembek, Scott R.; Jedlovec, Gary J.; Lapenta, William M.

    2008-01-01

    Forecast precipitation and radar characteristics are used by operational centers to guide the issuance of advisory products. As operational numerical weather prediction is performed at increasingly finer spatial resolution, convective precipitation traditionally represented by sub-grid scale parameterization schemes is now being determined explicitly through single- or multi-moment bulk water microphysics routines. Gains in forecasting skill are expected through improved simulation of clouds and their microphysical processes. High resolution model grids and advanced parameterizations are now available through steady increases in computer resources. As with any parameterization, their reliability must be measured through performance metrics, with errors noted and targeted for improvement. Furthermore, the use of these schemes within an operational framework requires an understanding of limitations and an estimate of biases so that forecasters and model development teams can be aware of potential errors. The National Severe Storms Laboratory (NSSL) Spring Experiments have produced daily, high resolution forecasts used to evaluate forecast skill among an ensemble with varied physical parameterizations and data assimilation techniques. In this research, high resolution forecasts of the 5-6 February 2008 Super Tuesday Outbreak are replicated using the NSSL configuration in order to evaluate two components of simulated convection on a large domain: sensitivities of quantitative precipitation forecasts to assumptions within a single-moment bulk water microphysics scheme, and to determine if these schemes accurately depict the reflectivity characteristics of well-simulated, organized, cold frontal convection. As radar returns are sensitive to the amount of hydrometeor mass and the distribution of mass among variably sized targets, radar comparisons may guide potential improvements to a single-moment scheme. In addition, object-based verification metrics are evaluated for their utility in gauging model performance and QPF variability.

  6. Towards a molecular logic machine

    NASA Astrophysics Data System (ADS)

    Remacle, F.; Levine, R. D.

    2001-06-01

    Finite state logic machines can be realized by pump-probe spectroscopic experiments on an isolated molecule. The most elaborate setup, a Turing machine, can be programmed to carry out a specific computation. We argue that a molecule can be similarly programmed, and provide examples using two photon spectroscopies. The states of the molecule serve as the possible states of the head of the Turing machine and the physics of the problem determines the possible instructions of the program. The tape is written in an alphabet that allows the listing of the different pump and probe signals that are applied in a given experiment. Different experiments using the same set of molecular levels correspond to different tapes that can be read and processed by the same head and program. The analogy to a Turing machine is not a mechanical one and is not completely molecular because the tape is not part of the molecular machine. We therefore also discuss molecular finite state machines, such as sequential devices, for which the tape is not part of the machine. Nonmolecular tapes allow for quite long input sequences with a rich alphabet (at the level of 7 bits) and laser pulse shaping experiments provide concrete examples. Single molecule spectroscopies show that a single molecule can be repeatedly cycled through a logical operation.

  7. Single incision laparoscopic surgery (SILS) inguinal hernia repair - recent clinical experiences of this novel technique.

    PubMed

    Yussra, Y; Sutton, P A; Kosai, N R; Razman, J; Mishra, R K; Harunarashid, H; Das, S

    2013-01-01

    Inguinal hernia remains the most commonly encountered surgical problem. Various methods of repair have been described, and the most suitable one debated. Single port access (SPA) surgery is a rapidly evolving field, and has the advantage of affording 'scarless' surgery. Single incision laparoscopic surgery (SILS) for inguinal hernia repair is seen to be feasible in both total extraperitoneal (TEP) and transabdominal pre-peritoneal (TAPP) approaches. Data and peri-operative information on both of these however are limited. We aimed to review the clinical experience, feasibility and short term complications related to laparoscopic inguinal hernia repair via single port access. A literature search was performed using Google Scholar, Springerlink Library, Highwire Press, Surgical Endoscopy Journal, World Journal of Surgery and Medscape. The following search terms were used: laparoscopic hernia repair, TAPP, TEP, single incision laparoscopic surgery (SILS). Fourteen articles in English language related to SILS inguinal hernia repair were identified. Nine articles were related to TEP repair and the remaining 5 to TAPP. A total of 340 patients were reported within these studies: 294 patients having a TEP repair and 46 a TAPP. Only two cases of recurrence were reported. Various ports have been utilized, including the SILS port, Tri-Port and a custom- made port using conventional laparoscopic instruments. The duration of surgery was 40-100 minutes and the average length of hospital stay was one day. Early outcomes of this novel technique show it to be feasible, safe and with potentially better cosmetic outcome.

  8. A disposable picolitre bioreactor for cultivation and investigation of industrially relevant bacteria on the single cell level.

    PubMed

    Grünberger, Alexander; Paczia, Nicole; Probst, Christopher; Schendzielorz, Georg; Eggeling, Lothar; Noack, Stephan; Wiechert, Wolfgang; Kohlheyer, Dietrich

    2012-05-08

    In the continuously growing field of industrial biotechnology the scale-up from lab to industrial scale is still a major hurdle to develop competitive bioprocesses. During scale-up the productivity of single cells might be affected by bioreactor inhomogeneity and population heterogeneity. Currently, these complex interactions are difficult to investigate. In this report, design, fabrication and operation of a disposable picolitre cultivation system is described, in which environmental conditions can be well controlled on a short time scale and bacterial microcolony growth experiments can be observed by time-lapse microscopy. Three exemplary investigations will be discussed emphasizing the applicability and versatility of the device. Growth and analysis of industrially relevant bacteria with single cell resolution (in particular Escherichia coli and Corynebacterium glutamicum) starting from one single mother cell to densely packed cultures is demonstrated. Applying the picolitre bioreactor, 1.5-fold increased growth rates of C. glutamicum wild type cells were observed compared to typical 1 litre lab-scale batch cultivation. Moreover, the device was used to analyse and quantify the morphological changes of an industrially relevant l-lysine producer C. glutamicum after artificially inducing starvation conditions. Instead of a one week lab-scale experiment, only 1 h was sufficient to reveal the same information. Furthermore, time lapse microscopy during 24 h picolitre cultivation of an arginine producing strain containing a genetically encoded fluorescence sensor disclosed time dependent single cell productivity and growth, which was not possible with conventional methods.

  9. A novel, cost-effective, multi-point Thomson scattering system on the Pegasus Toroidal Experiment (invited)

    DOE PAGES

    Schlossberg, David J.; Bodner, Grant M.; Bongard, Michael W.; ...

    2016-09-16

    Here, a novel, cost-effective, multi-point Thomson scattering system has been designed, implemented, and operated on the Pegasus Toroidal Experiment. Leveraging advances in Nd:YAG lasers, high-efficiency volume phase holographic transmission gratings, and increased quantum-efficiency Generation 3 image-intensified charge coupled device (ICCD) cameras, the system provides Thomson spectra at eight spatial locations for a single grating/camera pair. The on-board digitization of the ICCD camera enables easy modular expansion, evidenced by recent extension from 4 to 12 plasma/background spatial location pairs. Stray light is rejected using time-of-flight methods suited to gated ICCDs, and background light is blocked during detector readout by a fastmore » shutter. This –10 3 reduction in background light enables further expansion to up to 24 spatial locations. The implementation now provides single-shot T e(R) for n e > 5 × 10 18 m –3.« less

  10. A molecular logic gate.

    PubMed

    Kompa, K L; Levine, R D

    2001-01-16

    We propose a scheme for molecule-based information processing by combining well-studied spectroscopic techniques and recent results from chemical dynamics. Specifically it is discussed how optical transitions in single molecules can be used to rapidly perform classical (Boolean) logical operations. In the proposed way, a restricted number of states in a single molecule can act as a logical gate equivalent to at least two switches. It is argued that the four-level scheme can also be used to produce gain, because it allows an inversion, and not only a switching ability. The proposed scheme is quantum mechanical in that it takes advantage of the discrete nature of the energy levels but, we here discuss the temporal evolution, with the use of the populations only. On a longer time range we suggest that the same scheme could be extended to perform quantum logic, and a tentative suggestion, based on an available experiment, is discussed. We believe that the pumping can provide a partial proof of principle, although this and similar experiments were not interpreted thus far in our terms.

  11. Versatile single-chip event sequencer for atomic physics experiments

    NASA Astrophysics Data System (ADS)

    Eyler, Edward

    2010-03-01

    A very inexpensive dsPIC microcontroller with internal 32-bit counters is used to produce a flexible timing signal generator with up to 16 TTL-compatible digital outputs, with a time resolution and accuracy of 50 ns. This time resolution is easily sufficient for event sequencing in typical experiments involving cold atoms or laser spectroscopy. This single-chip device is capable of triggered operation and can also function as a sweeping delay generator. With one additional chip it can also concurrently produce accurately timed analog ramps, and another one-chip addition allows real-time control from an external computer. Compared to an FPGA-based digital pattern generator, this design is slower but simpler and more flexible, and it can be reprogrammed using ordinary `C' code without special knowledge. I will also describe the use of the same microcontroller with additional hardware to implement a digital lock-in amplifier and PID controller for laser locking, including a simple graphics-based control unit. This work is supported in part by the NSF.

  12. Improved Density Control in the Pegasus Toroidal Experiment using Internal Fueling

    NASA Astrophysics Data System (ADS)

    Thome, K. E.; Bongard, M. W.; Cole, J. A.; Fonck, R. J.; Redd, A. J.; Winz, G. R.

    2012-10-01

    Routine density control up to and exceeding the Greenwald limit is critical to key Pegasus operational scenarios, including non-solenoidal startup plasmas created using single-point helicity injection and high β Ohmic plasmas. Confinement scalings suggest it is possible to achieve very high β plasmas in Pegasus by lowering the toroidal field and increasing ne/ng. In the past, Pegasus achieved β ˜ 20% in high recycling Ohmic plasmas without running into any operational boundaries.footnotetext Garstka, G.D. et al., Phys. Plasmas 10, 1705 (2003) However, recent Ohmic experiments have demonstrated that Pegasus currently operates in an extremely low-recycling regime with R < 0.8 and Zeff ˜ 1 using improved vacuum conditioning techniques, such as Ti gettering and cryogenic pumping. Hence, it is difficult to achieve ne/ng> 0.3 with these improved wall conditions. Presently, gas is injected using low-field side (LFS) modified PV-10 valves. To attain high ne/ng operation and coincidentally separate core plasma and local current source fueling two new gas fueling capabilities are under development. A centerstack capillary injection system has been commissioned and is undergoing initial tests. A LFS movable midplane needle gas injection system is currently under design and will reach r/a ˜ 0.25. Initial results from both systems will be presented.

  13. Spotlight-8 Image Analysis Software

    NASA Technical Reports Server (NTRS)

    Klimek, Robert; Wright, Ted

    2006-01-01

    Spotlight is a cross-platform GUI-based software package designed to perform image analysis on sequences of images generated by combustion and fluid physics experiments run in a microgravity environment. Spotlight can perform analysis on a single image in an interactive mode or perform analysis on a sequence of images in an automated fashion. Image processing operations can be employed to enhance the image before various statistics and measurement operations are performed. An arbitrarily large number of objects can be analyzed simultaneously with independent areas of interest. Spotlight saves results in a text file that can be imported into other programs for graphing or further analysis. Spotlight can be run on Microsoft Windows, Linux, and Apple OS X platforms.

  14. SUNY beamline facilities at the National Synchrotron Light Source (Final Report)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Coppens, Philip

    2003-06-22

    The DOE sponsored SUNY synchrotron project has involved close cooperation among faculty at several SUNY campuses. A large number of students and postdoctoral associates have participated in its operation which was centered at the X3 beamline of the National Synchrotron Light Source at Brookhaven National Laboratory. Four stations with capabilities for Small Angle Scattering, Single Crystal and Powder and Surface diffraction and EXAFS were designed and operated with capability to perform experiments at very low as well as elevated temperatures and under high vacuum. A large amount of cutting-edge science was performed at the facility, which in addition provided excellentmore » training for students and postdoctoral scientists in the field.« less

  15. Browns Ferry-1 single-loop operation tests

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    March-Leuba, J.; Wood, R.T.; Otaduy, P.J.

    1985-09-01

    This report documents the results of the stability tests performed on February 9, 1985, at the Browns Ferry Nuclear Power Plant Unit 1 under single-loop operating conditions. The observed increase in neutron noise during single-loop operation is solely due to an increase in flow noise. The Browns Ferry-1 reactor has been found to be stable in all modes of operation attained during the present tests. The most unstable test plateau corresponded to minimum recirculation pump speed in single-loop operation (test BFTP3). This operating condition had the minimum flow and maximum power-to-flow ratio. The estimated decay ratio in this plateau ismore » 0.53. The decay ratio decreased as the flow was increased during single-loop operation (down to 0.34 for test plateau BFTP6). This observation implies that the core-wide reactor stability follows the same trends in single-loop as it does in two-loop operation. Finally, no local or higher mode instabilities were found in the data taken from local power range monitors. The decay ratios estimated from the local power range monitors were not significantly different from those estimated from the average power range monitors.« less

  16. Cutting performance orthogonal test of single plane puncture biopsy needle based on puncture force

    NASA Astrophysics Data System (ADS)

    Xu, Yingqiang; Zhang, Qinhe; Liu, Guowei

    2017-04-01

    Needle biopsy is a method to extract the cells from the patient's body with a needle for tissue pathological examination. Many factors affect the cutting process of soft tissue, including the geometry of the biopsy needle, the mechanical properties of the soft tissue, the parameters of the puncture process and the interaction between them. This paper conducted orthogonal experiment of main cutting parameters based on single plane puncture biopsy needle, and obtained the cutting force curve of single plane puncture biopsy needle by studying the influence of the inclination angle, diameter and velocity of the single plane puncture biopsy needle on the puncture force of the biopsy needle. Stage analysis of the cutting process of biopsy needle puncture was made to determine the main influencing factors of puncture force during the cutting process, which provides a certain theoretical support for the design of new type of puncture biopsy needle and the operation of puncture biopsy.

  17. Numbers and functional lateralization: A visual half-field and dichotic listening study in proficient bilinguals.

    PubMed

    Klichowski, Michal; Króliczak, Gregory

    2017-06-01

    Potential links between language and numbers and the laterality of symbolic number representations in the brain are still debated. Furthermore, reports on bilingual individuals indicate that the language-number interrelationships might be quite complex. Therefore, we carried out a visual half-field (VHF) and dichotic listening (DL) study with action words and different forms of symbolic numbers used as stimuli to test the laterality of word and number processing in single-, dual-language and mixed -task and language- contexts. Experiment 1 (VHF) showed a significant right visual field/left hemispheric advantage in response accuracy for action word, as compared to any form of symbolic number processing. Experiment 2 (DL) revealed a substantially reversed effect - a significant right ear/left hemisphere advantage for arithmetic operations as compared to action word processing, and in response times in single- and dual-language contexts for number vs. action words. All these effects were language independent. Notably, for within-task response accuracy compared across modalities significant differences were found in all studied contexts. Thus, our results go counter to findings showing that action-relevant concepts and words, as well as number words are represented/processed primarily in the left hemisphere. Instead, we found that in the auditory context, following substantial engagement of working memory (here: by arithmetic operations), there is a subsequent functional reorganization of processing single stimuli, whether verbs or numbers. This reorganization - their weakened laterality - at least for response accuracy is not exclusive to processing of numbers, but the number of items to be processed. For response times, except for unpredictable tasks in mixed contexts, the "number problem" is more apparent. These outcomes are highly relevant to difficulties that simultaneous translators encounter when dealing with lengthy auditory material in which single items such as number words (and possibly other types of key words) need to be emphasized. Our results may also shed a new light on the "mathematical savant problem". Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Single-incision laparoscopic surgery and conventional laparoscopic treatment of varicocele in adolescents: Comparison between two techniques.

    PubMed

    Marte, Antonio; Pintozzi, Lucia; Cavaiuolo, Silvia; Parmeggiani, Pio

    2014-01-01

    Single-incision laparoscopic surgery (SILS) has gained great popularity in paediatric surgery due to its minimally invasive approach and improved cosmetic results. Notwithstanding, reports describing its adoption in children are still fragmentary and some perplexities have been raised by some surgeons. We reviewed our experience with the SILS Palomo varicocelectomy procedure (SIL-V) in children and adolescents, comparing this group with a similar series operated using conventional laparoscopic varicocelectomy (CL-V). A total of 69 Palomo laparoscopic varicocelectomies were performed in patients aged 11-17 years from January 2011 to January 2013. Indications for surgery included grades II-III varicocele or ipsilateral testicular hypotrophy. The SIL-V procedure was performed in 44 patients with roticulating and conventional 5 mm instruments. Testicular vessels were isolated "en bloc," clipped and cut. Operating time, visual analogue scale and post-operative results were compared to a similar group of 25 patients operated with CL-V. No patient of the SIL-V group required conversion to conventional laparoscopy, none to open surgery. Mean operative time was 22 min (range: 19-28) in the SIL-V group, not significantly different compared with CL-V (mean 21 min, range: 18-25). All patients experienced a smooth recovery from surgery without any complications, and were discharged on day 1. No difficulties were found in the SIL-V group. The post-operative pain score was significantly better in SIL-V. The SIL-V procedure is safe and effective and allows a fast and efficient isolation of the vascular bundle. The use of conventional instruments is technically feasible in SIL-V.

  19. Cognitive patterns: giving autonomy some context

    NASA Astrophysics Data System (ADS)

    Dumond, Danielle; Stacy, Webb; Geyer, Alexandra; Rousseau, Jeffrey; Therrien, Mike

    2013-05-01

    Today's robots require a great deal of control and supervision, and are unable to intelligently respond to unanticipated and novel situations. Interactions between an operator and even a single robot take place exclusively at a very low, detailed level, in part because no contextual information about a situation is conveyed or utilized to make the interaction more effective and less time consuming. Moreover, the robot control and sensing systems do not learn from experience and, therefore, do not become better with time or apply previous knowledge to new situations. With multi-robot teams, human operators, in addition to managing the low-level details of navigation and sensor management while operating single robots, are also required to manage inter-robot interactions. To make the most use of robots in combat environments, it will be necessary to have the capability to assign them new missions (including providing them context information), and to have them report information about the environment they encounter as they proceed with their mission. The Cognitive Patterns Knowledge Generation system (CPKG) has the ability to connect to various knowledge-based models, multiple sensors, and to a human operator. The CPKG system comprises three major internal components: Pattern Generation, Perception/Action, and Adaptation, enabling it to create situationally-relevant abstract patterns, match sensory input to a suitable abstract pattern in a multilayered top-down/bottom-up fashion similar to the mechanisms used for visual perception in the brain, and generate new abstract patterns. The CPKG allows the operator to focus on things other than the operation of the robot(s).

  20. Ultrastable, Zerodur-based optical benches for quantum gas experiments.

    PubMed

    Duncker, Hannes; Hellmig, Ortwin; Wenzlawski, André; Grote, Alexander; Rafipoor, Amir Jones; Rafipoor, Mona; Sengstock, Klaus; Windpassinger, Patrick

    2014-07-10

    Operating ultracold quantum gas experiments outside of a laboratory environment has so far been a challenging goal, largely due to the lack of sufficiently stable optical systems. In order to increase the thermal stability of free-space laser systems, the application of nonstandard materials such as glass ceramics is required. Here, we report on Zerodur-based optical systems which include single-mode fiber couplers consisting of multiple components jointed by light-curing adhesives. The thermal stability is thoroughly investigated, revealing excellent fiber-coupling efficiencies between 0.85 and 0.92 in the temperature range from 17°C to 36°C. In conjunction with successfully performed vibration tests, these findings qualify our highly compact systems for atom interferometry experiments aboard a sounding rocket as well as various other quantum information and sensing applications.

  1. Photocatalytic destruction of chlorinated solvents in water with solar energy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pacheco, J.E.; Prairie, M.R.; Yellowhorse, L.

    1993-08-01

    Sandia National Laboratories and the National Renewable Energy Laboratory are developing a photocatalytic process to destroy organic contaminants in water. Tests with common water pollutants have been conducted at Sandia's Solar Thermal Facility using a near commercial scale, single-axis tracking parabolic trough system with a glass pipe reactor mounted at its focus. Experiments at this scale provide verification of laboratory studies and allow examination of design and operation issues at a real-lifescale. The catalyst, titanium dioxide (TiO[sub 2]), is a harmless material found in paint, cosmetics, and toothpaste. Experiments were conducted to determine the effects of key process parameters onmore » destruction rates of chlorinated organic compounds that are common water pollutants. This paper summarizes the engineering-scale results of these experiments and analyses.« less

  2. Highly flexible pulse programmer for NMR applications

    NASA Technical Reports Server (NTRS)

    Dart, J.; Burum, D. P.; Rhim, W. K.

    1980-01-01

    A pulse generator for NMR application is described. Eighteen output channels are provided to allow use in single and double resonance experiments. Complex pulse sequences may be generated by loading instructions into a 256-word by 16-bit program memory. Features of the pulse generator include programmable time delays from 0.5 micros to 1000 s, branching and looping instructions, and the ability to be loaded and operated either manually or from a PDP-11/10 computer.

  3. Status of the isophot detector development

    NASA Technical Reports Server (NTRS)

    Wolf, J.; Lemke, D.; Burgdorf, M.; Groezinger, U.; Hajduk, CH.

    1989-01-01

    ISOPHOT is one of the four focal plane experiments of the European Space Agency's Infrared Space Observatory (ISO). Scheduled for a 1993 launch, it will operate extrinsic silicon and germanium photoconductors at low temperature and low background during the longer than 18 month mission. These detectors cover the wavelength range from 2.5 to 200 microns and are used as single elements and in arrays. A cryogenic preamplifier was developed to read out a total number of 223 detector pixels.

  4. Self-assembled quantum dot structures in a hexagonal nanowire for quantum photonics.

    PubMed

    Yu, Ying; Dou, Xiu-Ming; Wei, Bin; Zha, Guo-Wei; Shang, Xiang-Jun; Wang, Li; Su, Dan; Xu, Jian-Xing; Wang, Hai-Yan; Ni, Hai-Qiao; Sun, Bao-Quan; Ji, Yuan; Han, Xiao-Dong; Niu, Zhi-Chuan

    2014-05-01

    Two types of quantum nanostructures based on self-assembled GaAs quantumdots embedded into GaAs/AlGaAs hexagonal nanowire systems are reported, opening a new avenue to the fabrication of highly efficient single-photon sources, as well as the design of novel quantum optics experiments and robust quantum optoelectronic devices operating at higher temperature, which are required for practical quantum photonics applications. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Stratification and segregation features of pulverized electronic waste in flowing film concentration.

    PubMed

    Vidyadhar, A; Chalavadi, G; Das, A

    2013-03-30

    Gravity separation of metals from plastics in pulverized e-waste using flowing film concentration in a shaking table was investigated. Over 51% rejection of plastics in a single stage operation was achieved under optimum conditions. The shaking table was shown to be suitable for processing ground PCBs. Pulverized e-waste containing 22% metals was enriched to around 40% metals in a single pass. Statistical models for the mass yield of metal-rich stream and its grade were developed by design of experiments. Optimization was carried out to maximize the mass yield at a target product grade and preferred operating regimes were established. Experiments were designed to prevent metal loss and over 95% recovery values were obtained under all conditions. Settling distances of metals and plastics were computed and shown to be good indicators of separation performance. Particle morphology and stratification in the troughs in between the riffles were shown to influence the separation significantly. Water flow-assisted motion of the plastics was captured and its role in determining the effectiveness of separation was described. The efficacy of tabling was well established for treating ground PCBs. The wet process was shown to be environment friendly and sustainable. It is also relatively cheap and has good potential for industrial application. However, rigorous cost estimates will be required before commercial application. Copyright © 2013 Elsevier Ltd. All rights reserved.

  6. Cryogenic fluid management experiment

    NASA Technical Reports Server (NTRS)

    Eberhardt, R. N.; Bailey, W. J.; Fester, D. A.

    1981-01-01

    The cryogenic fluid management experiment (CFME), designed to characterize subcritical liquid hydrogen storage and expulsion in the low-q space environment, is discussed. The experiment utilizes a fine mesh screen fluid management device to accomplish gas-free liquid expulsion and a thermodynamic vent system to intercept heat leak and control tank pressure. The experiment design evolved from a single flight prototype to provision for a multimission (up to 7) capability. A detailed design of the CFME, a dynamic test article, and dedicated ground support equipment were generated. All materials and parts were identified, and components were selected and specifications prepared. Long lead titanium pressurant spheres and the flight tape recorder and ground reproduce unit were procured. Experiment integration with the shuttle orbiter, Spacelab, and KSC ground operations was coordinated with the appropriate NASA centers, and experiment interfaces were defined. Phase 1 ground and flight safety reviews were conducted. Costs were estimated for fabrication and assembly of the CFME, which will become the storage and supply tank for a cryogenic fluid management facility to investigate fluid management in space.

  7. The single grain fusion dating approach: Determining the factors that control white mica 40Ar/39Ar age formation during HP metamorphism of the Cycladic Blueschist Unit, Greece

    NASA Astrophysics Data System (ADS)

    Uunk, Bertram; Wijbrans, Jan; Brouwer, Fraukje

    2017-04-01

    White mica 40Ar/39Ar dating is a proven powerful tool for constraining the timing and rate of metamorphism, deformation and exhumation. However, for high-pressure metamorphic rocks dating often results in wide age ranges, which are not in agreement with constraints from other isotopic systems, indicating that geological and chemical processes complicate straightforward 40Ar/39Ar dating. Despite hosting one of the largest geochronological datasets in the world, the Cycladic Blueschist Unit in Greece is presently one of the focal areas in the discussion on the interpretation of metamorphic 40Ar/39Ar ages. Previous phengite multi grain step heating experiments commonly yielded undulating age spectra ranging between 20 - 60 Ma. While some studies attempt to assign geological significance to these ages, others argue the ages are geologically meaningless and the result of the interplay between partial diffusive resetting and continued crystallization. By taking an alternative approach of multiple single grain fusion experiments, this study investigates age heterogeneity between samples of contrasting metamorphic facies, rheology and strain from the Cycladic islands of Syros and Sifnos. Comparing the size and shape of single grain fusion age distributions at the grain, rock, outcrop and island scale allows determination of the scale at which different age-forming processes operate. Resulting ages show a previously unreported consistent variation between different outcrops, moving from the eclogite-blueschist facies (55-45 Ma) to greenschist overprinting (40-30 Ma). This indicates that outcrop scale homogeneous resetting is the dominant processes for age formation in the CBU. Single grain age variation at the sample and outcrop scale is only limited to 10 Ma, indicating a smaller but observable role for local age perturbing processes of incomplete resetting, continued (re)crystallization or infiltration of excess argon. Some of the partially overprinted samples show homogeneous single grain age populations, indicating at least a partial role for efficient resetting by thermally activated diffusion at the outcrop scale. Traditional multi grain step heating experiments on the same samples yield flat plateaus for various single grain age distributions, indicating that age heterogeneities resolved by single grain fusion dating are mixed to a meaningless average in step heating experiments. In contrast, our approach leads to a better understanding of the processes responsible for age formation during high pressure metamorphism.

  8. Nanomanipulation of Single RNA Molecules by Optical Tweezers

    PubMed Central

    Stephenson, William; Wan, Gorby; Tenenbaum, Scott A.; Li, Pan T. X.

    2014-01-01

    A large portion of the human genome is transcribed but not translated. In this post genomic era, regulatory functions of RNA have been shown to be increasingly important. As RNA function often depends on its ability to adopt alternative structures, it is difficult to predict RNA three-dimensional structures directly from sequence. Single-molecule approaches show potentials to solve the problem of RNA structural polymorphism by monitoring molecular structures one molecule at a time. This work presents a method to precisely manipulate the folding and structure of single RNA molecules using optical tweezers. First, methods to synthesize molecules suitable for single-molecule mechanical work are described. Next, various calibration procedures to ensure the proper operations of the optical tweezers are discussed. Next, various experiments are explained. To demonstrate the utility of the technique, results of mechanically unfolding RNA hairpins and a single RNA kissing complex are used as evidence. In these examples, the nanomanipulation technique was used to study folding of each structural domain, including secondary and tertiary, independently. Lastly, the limitations and future applications of the method are discussed. PMID:25177917

  9. Athermal operation of multi-section slotted tunable lasers.

    PubMed

    Wallace, M J; O'Reilly Meehan, R; Enright, R; Bello, F; McCloskey, D; Barabadi, B; Wang, E N; Donegan, J F

    2017-06-26

    Two distinct athermal bias current procedures based on thermal tuning are demonstrated for a low-cost, monotlithic, three section slotted single mode laser, achieving mode-hop free wavelength stability of ± 0.04 nm / 5 GHz over a temperature range of 8-47 °C. This is the first time that athermal performance has been demonstrated for a three-section slotted laser with simple fabrication, and is well within the 50 GHz grid spacing specified for DWDM systems. This performance is similar to experiments on more complex DS-DBR lasers, indicating that strong athermal performance can be achieved using our lower-cost three section devices. An analytical model and thermoreflectance measurements provide further insight into the operation of multi-section lasers and lay the foundation for an accurate predictive tool for optimising such devices for athermal operation.

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Strickland, Christopher E.; Lawter, Amanda R.; Qafoku, Nikolla

    Isotopes of iodine were generated during plutonium production from nine production reactors at the U.S. Department of Energy Hanford Site. The long half-life 129I generated at the Hanford Site during reactor operations was 1) stored in single-shell and double-shell tanks, 2) discharged to liquid disposal sites (e.g., cribs and trenches), 3) released to the atmosphere during fuel reprocessing operations, or 4) captured by off-gas absorbent devices (silver reactors) at chemical separations plants (PUREX, B-Plant, T-Plant, and REDOX). Releases of 129I to the subsurface have resulted in several large, though dilute, plumes in the groundwater, including the plume in the 200-UP-1more » operable unit. There is also 129I remaining in the vadose zone beneath disposal or leak locations. Because 129I is an uncommon contaminant, relevant remediation experience and scientific literature are limited.« less

  11. Evaluation of 300 Minimally Invasive Liver Resections at a Single Institution

    PubMed Central

    Koffron, Alan J.; Auffenberg, Greg; Kung, Robert; Abecassis, Michael

    2007-01-01

    Objective: We present the largest, most comprehensive, single center experience to date of minimally invasive liver resection (MILR). Summary Background Data: Despite anecdotal reports of MILR, few large single center reports have examined these procedures by comparing them to their open counterparts. Methods: Three hundred MILR were performed between July 2001 and November 2006 at our center for both benign and malignant conditions. These included 241 pure laparoscopic, 32 hand-assisted laparoscopic, and 27 laparoscopy-assisted open (hybrid) resections. These MILR were compared with 100 contemporaneous, cohort-matched open resections. MILR included segmentectomies (110), bisegmentectomies (63), left hepatectomies (47), right hepatectomies (64), extended right hepatectomies (8), and caudate lobe (8) resections. Benign etiologies encompassed cysts (70), hemangiomata (37), focal nodular hyperplasia (FNH) (23), adenomata (47), and 20 live donor right lobectomies. Malignant etiologies included primary (43) and metastatic (60) tumors. Hepatic fibrosis/cirrhosis was present in 25 of 103 patients with malignant diseases (24%). Results: There was high data consistency within the 3 types of MILR. MILR compared favorably with standard open techniques: operative times (99 vs. 182 minutes), blood loss (102 vs. 325 ml), transfusion requirement (2 of 300 vs. 8 of 100), length of stay (1.9 vs. 5.4 days), overall operative complications (9.3% vs. 22%), and local malignancy recurrence (2% vs. 3%). No port-site recurrences occurred. Conversion from laparoscopic to hand-assisted laparoscopic resection occurred in 20 patients (6%), with no conversions to open. No hand-assisted procedures were converted to open, but 2 laparoscopy-assisted (7%) were converted to open. Conclusion: Our data show that MILR outcomes compare favorably with those of the open standard technique. Our experience suggests that MILR of varying magnitudes is safe and effective for both benign and malignant conditions. PMID:17717442

  12. An integrated instrumental setup for the combination of atomic force microscopy with optical spectroscopy.

    PubMed

    Owen, R J; Heyes, C D; Knebel, D; Röcker, C; Nienhaus, G U

    2006-07-01

    In recent years, the study of single biomolecules using fluorescence microscopy and atomic force microscopy (AFM) techniques has resulted in a plethora of new information regarding the physics underlying these complex biological systems. It is especially advantageous to be able to measure the optical, topographical, and mechanical properties of single molecules simultaneously. Here an AFM is used that is especially designed for integration with an inverted optical microscope and that has a near-infrared light source (850 nm) to eliminate interference between the optical experiment and the AFM operation. The Tip Assisted Optics (TAO) system consists of an additional 100 x 100-microm(2) X-Y scanner for the sample, which can be independently and simultaneously used with the AFM scanner. This allows the offset to be removed between the confocal optical image obtained with the sample scanner and the simultaneously acquired AFM topography image. The tip can be positioned exactly into the optical focus while the user can still navigate within the AFM image for imaging or manipulation of the sample. Thus the tip-enhancement effect can be maximized and it becomes possible to perform single molecule manipulation experiments within the focus of a confocal optical image. Here this is applied to simultaneous measurement of single quantum dot fluorescence and topography with high spatial resolution. (c) 2006 Wiley Periodicals, Inc.

  13. Assimilative modeling of low latitude ionosphere

    NASA Technical Reports Server (NTRS)

    Pi, Xiaoqing; Wang, Chunining; Hajj, George A.; Rosen, I. Gary; Wilson, Brian D.; Mannucci, Anthony J.

    2004-01-01

    In this paper we present an observation system simulation experiment for modeling low-latitude ionosphere using a 3-dimensional (3-D) global assimilative ionospheric model (GAIM). The experiment is conducted to test the effectiveness of GAIM with a 4-D variational approach (4DVAR) in estimation of the ExB drift and thermospheric wind in the magnetic meridional planes simultaneously for all longitude or local time sectors. The operational Global Positioning System (GPS) satellites and the ground-based global GPS receiver network of the International GPS Service are used in the experiment as the data assimilation source. 'The optimization of the ionospheric state (electron density) modeling is performed through a nonlinear least-squares minimization process that adjusts the dynamical forces to reduce the difference between the modeled and observed slant total electron content in the entire modeled region. The present experiment for multiple force estimations reinforces our previous assessment made through single driver estimations conducted for the ExB drift only.

  14. MR-guided focused ultrasound robot for performing experiments on large animals

    NASA Astrophysics Data System (ADS)

    Mylonas, N.; Damianou, C.

    2011-09-01

    Introduction: In this paper an experimental MRI-guided focused ultrasound robot for large animals is presented. Materials and methods: A single element spherically focused transducer of 4 cm diameter, focusing at 10 cm and operating at 1 MHz was used. A positioning device was developed in order to scan the ultrasound transducer for performing MR-guided focused ultrasound experiments in large animals such as pig, sheep and dog. The positioning device incorporates only MRI compatible materials such as piezoelectric motors, Acrylonitrile Butadiene Styrene (ABS) plastic, brass screws, and brass pulleys. The system is manufactured automatically using a rapid prototyping system. Results: The system was tested successfully in a number of animals for various tasks (creation of single lesions, creation of overlapping lesions, and MR compatibility). Conclusions: A simple, cost effective, portable positioning device has been developed which can be used in virtually any clinical MRI scanner since it can be sited on the scanner's table. The propagation of HIFU can be via a lateral or superior-inferior approach. This system has the potential to be marketed as a cost effective solution for performing experiments in small and large animals.

  15. Characterizing new compositions of [001]C relaxor ferroelectric single crystals using a work-energy model

    NASA Astrophysics Data System (ADS)

    Gallagher, John A.

    2016-04-01

    The desired operating range of ferroelectric materials with compositions near the morphotropic phase boundary is limited by field induced phase transformations. In [001]C cut and poled relaxor ferroelectric single crystals the mechanically driven ferroelectric rhombohedral to ferroelectric orthorhombic phase transformation is hindered by antagonistic electrical loading. Instability around the phase transformation makes the current experimental technique for characterization of the large field behavior very time consuming. Characterization requires specialized equipment and involves an extensive set of measurements under combined electrical, mechanical, and thermal loads. In this work a mechanism-based model is combined with a more limited set of experiments to obtain the same results. The model utilizes a work-energy criterion that calculates the mechanical work required to induce the transformation and the required electrical work that is removed to reverse the transformation. This is done by defining energy barriers to the transformation. The results of the combined experiment and modeling approach are compared to the fully experimental approach and error is discussed. The model shows excellent predictive capability and is used to substantially reduce the total number of experiments required for characterization. This decreases the time and resources required for characterization of new compositions.

  16. Congenital megaprepuce: a 12-year experience (52 cases) of this specific form of buried penis.

    PubMed

    Rod, Julien; Desmonts, Alexis; Petit, Thierry; Ravasse, Philippe

    2013-12-01

    Congenital megaprepuce is a specific form of buried penis. Children affected by this malformation usually suffer from a subjective difficulty in voiding which is the main indication for early surgical correction. The aim of this study was to report a single center's 12-year experience in the treatment of megaprepuce in children, describing the surgical procedure we used to treat it and the results. We retrospectively reviewed the charts of all children who underwent congenital megaprepuce repair between January 1999 and August 2011 in our institution. Fifty-two children were operated during the study period. Our single surgical technique, not an original one, consists of fixing the penile shaft at the base of the penis, and widely reducing the inner prepuce. Four children (8%) underwent revision surgery but according to our criteria a very good result was observed in only 23 patients, and a less good but still acceptable result in 25 patients. Our 12-year experience in the surgical treatment of congenital megaprepuce demonstrated satisfying results from a safe and simple surgical technique, but to achieve the optimum result remains difficult. Copyright © 2012 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.

  17. A Terrestrial Microbial Fuel Cell for Powering a Single-Hop Wireless Sensor Network.

    PubMed

    Zhang, Daxing; Zhu, Yingmin; Pedrycz, Witold; Guo, Yongxian

    2016-05-18

    Microbial fuel cells (MFCs) are envisioned as one of the most promising alternative renewable energy sources because they can generate electric current continuously while treating waste. Terrestrial Microbial Fuel Cells (TMFCs) can be inoculated and work on the use of soil, which further extends the application areas of MFCs. Energy supply, as a primary influential factor determining the lifetime of Wireless Sensor Network (WSN) nodes, remains an open challenge in sensor networks. In theory, sensor nodes powered by MFCs have an eternal life. However, low power density and high internal resistance of MFCs are two pronounced problems in their operation. A single-hop WSN powered by a TMFC experimental setup was designed and experimented with. Power generation performance of the proposed TMFC, the relationships between the performance of the power generation and the environment temperature, the water content of the soil by weight were measured by experiments. Results show that the TMFC can achieve good power generation performance under special environmental conditions. Furthermore, the experiments with sensor data acquisition and wireless transmission of the TMFC powering WSN were carried out. We demonstrate that the obtained experimental results validate the feasibility of TMFCs powering WSNs.

  18. A Terrestrial Microbial Fuel Cell for Powering a Single-Hop Wireless Sensor Network

    PubMed Central

    Zhang, Daxing; Zhu, Yingmin; Pedrycz, Witold; Guo, Yongxian

    2016-01-01

    Microbial fuel cells (MFCs) are envisioned as one of the most promising alternative renewable energy sources because they can generate electric current continuously while treating waste. Terrestrial Microbial Fuel Cells (TMFCs) can be inoculated and work on the use of soil, which further extends the application areas of MFCs. Energy supply, as a primary influential factor determining the lifetime of Wireless Sensor Network (WSN) nodes, remains an open challenge in sensor networks. In theory, sensor nodes powered by MFCs have an eternal life. However, low power density and high internal resistance of MFCs are two pronounced problems in their operation. A single-hop WSN powered by a TMFC experimental setup was designed and experimented with. Power generation performance of the proposed TMFC, the relationships between the performance of the power generation and the environment temperature, the water content of the soil by weight were measured by experiments. Results show that the TMFC can achieve good power generation performance under special environmental conditions. Furthermore, the experiments with sensor data acquisition and wireless transmission of the TMFC powering WSN were carried out. We demonstrate that the obtained experimental results validate the feasibility of TMFCs powering WSNs. PMID:27213346

  19. 76 FR 76297 - Drawbridge Operation Regulation; Willamette River, Portland, OR

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-07

    .... This deviation allows single leaf operations during rehabilitation and requires a two hour advance notification for a single leaf opening. DATES: This deviation is effective from 6 a.m. on December 1, 2011...: Multnomah County has requested to operate the Morrison Bascule Bridge with single leaf openings with two...

  20. Segmented ion thruster

    NASA Technical Reports Server (NTRS)

    Brophy, John R. (Inventor)

    1993-01-01

    Apparatus and methods for large-area, high-power ion engines comprise dividing a single engine into a combination of smaller discharge chambers (or segments) configured to operate as a single large-area engine. This segmented ion thruster (SIT) approach enables the development of 100-kW class argon ion engines for operation at a specific impulse of 10,000 s. A combination of six 30-cm diameter ion chambers operating as a single engine can process over 100 kW. Such a segmented ion engine can be operated from a single power processor unit.

  1. Watt-level widely tunable single-mode emission by injection-locking of a multimode Fabry-Perot quantum cascade laser

    NASA Astrophysics Data System (ADS)

    Chevalier, Paul; Piccardo, Marco; Anand, Sajant; Mejia, Enrique A.; Wang, Yongrui; Mansuripur, Tobias S.; Xie, Feng; Lascola, Kevin; Belyanin, Alexey; Capasso, Federico

    2018-02-01

    Free-running Fabry-Perot lasers normally operate in a single-mode regime until the pumping current is increased beyond the single-mode instability threshold, above which they evolve into a multimode state. As a result of this instability, the single-mode operation of these lasers is typically constrained to few percents of their output power range, this being an undesired limitation in spectroscopy applications. In order to expand the span of single-mode operation, we use an optical injection seed generated by an external-cavity single-mode laser source to force the Fabry-Perot quantum cascade laser into a single-mode state in the high current range, where it would otherwise operate in a multimode regime. Utilizing this approach, we achieve single-mode emission at room temperature with a tuning range of 36 cm-1 and stable continuous-wave output power exceeding 1 W at 4.5 μm. Far-field measurements show that a single transverse mode is emitted up to the highest optical power, indicating that the beam properties of the seeded Fabry-Perot laser remain unchanged as compared to free-running operation.

  2. Polarized Solid State Target

    NASA Astrophysics Data System (ADS)

    Dutz, Hartmut; Goertz, Stefan; Meyer, Werner

    2017-01-01

    The polarized solid state target is an indispensable experimental tool to study single and double polarization observables at low intensity particle beams like tagged photons. It was one of the major components of the Crystal-Barrel experiment at ELSA. Besides the operation of the 'CB frozen spin target' within the experimental program of the Crystal-Barrel collaboration both collaborative groups of the D1 project, the polarized target group of the Ruhr Universität Bochum and the Bonn polarized target group, have made significant developments in the field of polarized targets within the CRC16. The Bonn polarized target group has focused its work on the development of technically challenging polarized solid target systems towards the so called '4π continuous mode polarized target' to operate them in combination with 4π-particle detection systems. In parallel, the Bochum group has developed various highly polarized deuterated target materials and high precision NMR-systems, in the meantime used for polarization experiments at CERN, JLAB and MAMI, too.

  3. Measurement of the attenuation length of argon scintillation light in the ArDM LAr TPC

    NASA Astrophysics Data System (ADS)

    Calvo, J.; Cantini, C.; Crivelli, P.; Daniel, M.; Di Luise, S.; Gendotti, A.; Horikawa, S.; Molina-Bueno, L.; Montes, B.; Mu, W.; Murphy, S.; Natterer, G.; Nguyen, K.; Periale, L.; Quan, Y.; Radics, B.; Regenfus, C.; Romero, L.; Rubbia, A.; Santorelli, R.; Sergiampietri, F.; Viant, T.; Wu, S.

    2018-01-01

    We report on a measurement of the attenuation length for the scintillation light in the tonne size liquid argon target of the ArDM dark matter experiment. The data was recorded in the first underground operation of the experiment in single-phase operational mode. The results were achieved by comparing the light yield spectra from 39Ar and 83mKr to a description of the ArDM setup with a model of full light ray tracing. A relatively low value close to 0.5 m was found for the attenuation length of the liquid argon bulk to its own scintillation light. We interpret this result as a presence of optically active impurities in the liquid argon which are not filtered by the installed purification systems. We also present analyses of the argon gas employed for the filling and discuss cross sections in the vacuum ultraviolet of various molecules in respect to purity requirements in the context of large liquid argon installations.

  4. Space storable propellant performance program coaxial injector characterization

    NASA Technical Reports Server (NTRS)

    Burick, R. J.

    1972-01-01

    An experimental program was conducted to characterize the circular coaxial injector concept for application with the space-storable gas/liquid propellant combination FLOX(82.6% F2)/CH4(g) at high pressure. The primary goal of the program was to obtain high characteristic velocity efficiency in conjunction with acceptable injector/chamber compatibility. A series of subscale (single element) cold flow and hot fire experiments was employed to establish design criteria for a 3000-lbf (sea level) engine operating at 500 psia. The subscale experiments characterized both high performance core elements and peripheral elements with enhanced injector/chamber compatibility. The full-scale injector which evolved from the study demonstrated a performance level of 99 percent of the theoretical shifting characteristic exhaust velocity with low chamber heat flux levels. A 44-second-duration firing demonstrated the durability of the injector. Parametric data are presented that are applicable for the design of circular, coaxial injectors that operate with injection dynamics (fuel and oxidizer velocity, etc.) similar to those employed in the work reported.

  5. A contemporary, single-institutional experience of surgical versus expectant management of congenital heart disease in trisomy 13 and 18 patients.

    PubMed

    Costello, John P; Weiderhold, Allison; Louis, Clauden; Shaughnessy, Conner; Peer, Syed M; Zurakowski, David; Jonas, Richard A; Nath, Dilip S

    2015-06-01

    The objective of this study was to examine a large institutional experience of patients with trisomy 13 and trisomy 18 in the setting of comorbid congenital heart disease and present the outcomes of surgical versus expectant management. It is a retrospective single-institution cohort study. Institutional review board approved this study. Thirteen consecutive trisomy 18 patients and three consecutive trisomy 13 patients (sixteen patients in total) with comorbid congenital heart disease who were evaluated by our institution's Division of Cardiovascular Surgery between January 2008 and December 2013 were included in the study. The primary outcome measures evaluated were operative mortality (for patients who received surgical management), overall mortality (for patients who received expectant management), and total length of survival during follow-up. Of the thirteen trisomy 18 patients, seven underwent surgical management and six received expectant management. With surgical management, operative mortality was 29 %, and 80 % of patients were alive after a median follow-up of 116 days. With expectant management, 50 % of patients died before hospital discharge. Of the three patients with trisomy 13, one patient underwent surgical management and two received expectant management. The patient who received surgical management with complete repair was alive at last follow-up over 2 years after surgery; both patients managed expectantly died before hospital discharge. Trisomy 13 and trisomy 18 patients with comorbid congenital heart disease can undergo successful cardiac surgical intervention. In this population, we advocate that nearly all patients with cardiovascular indications for operative congenital heart disease intervention should be offered complete surgical repair over palliative approaches for moderately complex congenital cardiac anomalies.

  6. Robotic transthoracic esophagectomy.

    PubMed

    Puntambekar, Shailesh; Kenawadekar, Rahul; Kumar, Sanjay; Joshi, Saurabh; Agarwal, Geetanjali; Reddy, Sunil; Mallik, Jainul

    2015-04-23

    We have initially published our experience with the robotic transthoracic esophagectomy in 32 patients from a single institute. The present paper is the extension of our experience with robotic system and to best of our knowledge this represents the largest series of robotic transthoracic esophagectomy worldwide. The objective of this study was to investigate the feasibility of the robotic transthoracic esophagectomy for esophageal cancer in a series of patients from a single institute. A retrospective review of medical records was conducted for 83 esophageal cancer patients who underwent robotic esophagectomy at our institute from December 2009 to December 2012. All patients underwent a thorough clinical examination and pre-operative investigations. All patients underwent robotic esophageal mobilization. En-bloc dissection with lymphadenectomy was performed in all cases with preservation of Azygous vein. Relevant data were gathered from medical records. The study population comprised of 50 men and 33 women with mean age of 59.18 years. The mean operative time was 204.94 mins (range 180 to 300). The mean blood loss was 86.75 ml (range 50 to 200). The mean number of lymph node yield was 18. 36 (range 13 to 24). None of the patient required conversion. The mean ICU stay and hospital stay was 1 day (range 1 to 3) and 10.37 days (range 10 to 13), respectively. A total of 16 (19.28%) complication were reported in these patents. Commonly reported complication included dysphagia, pleural effusion and anastomotic leak. No treatment related mortality was observed. After a median follow-up period of 10 months, 66 patients (79.52%) survived with disease free stage. We found robot-assisted thoracoscopic esophagectomy feasible in cases of esophageal cancer. The procedure allowed precise en-bloc dissection with lymphadenectomy in mediastinum with reduced operative time, blood loss and complications.

  7. Primary graft dysfunction and other selected complications of lung transplantation: A single-center experience of 983 patients.

    PubMed

    Meyers, Bryan F; de la Morena, Maite; Sweet, Stuart C; Trulock, Elbert P; Guthrie, Tracey J; Mendeloff, Eric N; Huddleston, Charles; Cooper, Joel D; Patterson, G Alexander

    2005-06-01

    We sought to review the incidence and outcome of lung transplantation complications observed over 15 years at a single center. We performed a retrospective review from our databases, tracking outcomes after adult and pediatric lung transplantation. The 983 operations between July 1988 and September 2003 included 277 pediatric and 706 adult recipients. Bilateral (74%), unilateral (19%), and living lobar transplants (4%) comprised the bulk of this experience. Retransplantations accounted for 44 (4.5%) of the operations. The groups differed by indication for transplantation. The adults included 57% with emphysema and 17% with cystic fibrosis, and the children included no patients with emphysema and 50% with cystic fibrosis. Hospital mortality was 96 (9.8%) of 983, including 46 (17%) of 277 of the children and 50 (7%) of 706 of the adults. The overall survival curves did not differ between adults and children ( P = .56). Freedom from bronchiolitis obliterans syndrome at 5 and 10 years was 45% and 18% for adults and 48% and 30% for children, respectively ( P = .53). The causes of death for adults included bronchiolitis obliterans syndrome (40%), respiratory failure (17%), and infection (14%), whereas the causes of death in children included bronchiolitis obliterans syndrome (35%), infection (28%), and respiratory failure (21%) ( P < .01). Posttransplantation lymphoproliferative disease occurred in 12% of pediatric recipients and 6% of adults ( P < .01). The frequency of treated airway complications did not differ between adults and children (9% vs 11%, P = .48). The frequency of primary graft dysfunction did not differ between children (22%) and adults (23%), despite disparity in the use of cardiopulmonary bypass. These results highlight major complications after lung transplantation. Despite differences in underlying diagnoses and operative techniques, the 2 cohorts of patients experienced remarkably similar outcomes.

  8. Single Neurosurgeon Operative Experience at Craig Joint Theater Hospital During the Afghanistan Surge (November 2010 to April 2011), Part II: Humanitarian Cases.

    PubMed

    Steele, John Joseph

    2017-01-01

    The Afghanistan Surge saw NATO troops working with their Afghan partners to remove Taliban governance and replace it with a more democratic model. As part of this endeavor, medical support for both trauma and humanitarian cases was needed. Identify and discuss disease trends to better prepare for future combat medical treatments. Retrospective review of operative experience from a neurosurgeon from November 2010 to April 2011. 63 cases were performed on 20 NATO and 43 Afghan patients. Combat-related neurotrauma represented 73% (46/63) of cases and humanitarian cases represented the remainder. The most common diseases among humanitarian cases were benign tumors (29%, 5/17), cranioplasty (23%, 4/17), obstructive hydrocephalus (11%, 2/17), nonobstructive hydrocephalus (11%, 2/17), hemifacial spasm (11%, 2/17), and cerebral angiography (11%, 2/17). There was 1 death from ventriculitis for a complication rate of 6%. In select well-nourished, patients with minimal risk of needing tracheostomy, humanitarian neurosurgery can be safely performed in theater with a complication rate (6%) no worse than patients operated on in the United States. Reprint & Copyright © 2017 Association of Military Surgeons of the U.S.

  9. One-Step Nucleic Acid Amplification in Breast Cancer Sentinel Lymph Node: A Single Institutional Experience and a Short Review

    PubMed Central

    Brambilla, Tatiana; Fiamengo, Barbara; Tinterri, Corrado; Testori, Alberto; Grassi, Massimo Maria; Sciarra, Amedeo; Abbate, Tommaso; Gatzemeier, Wolfgang; Roncalli, Massimo; Di Tommaso, Luca

    2015-01-01

    Sentinel lymph node (SLN) examination is a standard in breast cancer patients, with several methods employed along its 20 years history, the last one represented by one-step nucleic acid amplification (OSNA). The latter is a intra-operative molecular assay searching for CK19 mRNA as a surrogate of metastatic cells. Our 3 years experience with OSNA (1122 patients) showed results overlapping those recorded in the same institution with a morphological evaluation (930 patients) of SLN. In detail, the data of OSNA were almost identical to those observed with standard post-operative procedure in terms of patients with positive SLN (30%) and micrometastatic/macrometastatic involvement of SLN (respectively, 38–45 and 62–55%). By contrast, when OSNA was compared to the standard intraoperatory procedure, it was superior in terms of accuracy, prompting the use of this molecular assay as a very valid, and reproducible for intra-operative evaluation of SLN. Further possibilities prompting the use of OSNA range from adhesion to quality control programs, saving of medical time, ability to predict, during surgery, additional nodal metastasis, and molecular bio-banking. PMID:26131451

  10. One-Step Nucleic Acid Amplification in Breast Cancer Sentinel Lymph Node: A Single Institutional Experience and a Short Review.

    PubMed

    Brambilla, Tatiana; Fiamengo, Barbara; Tinterri, Corrado; Testori, Alberto; Grassi, Massimo Maria; Sciarra, Amedeo; Abbate, Tommaso; Gatzemeier, Wolfgang; Roncalli, Massimo; Di Tommaso, Luca

    2015-01-01

    Sentinel lymph node (SLN) examination is a standard in breast cancer patients, with several methods employed along its 20 years history, the last one represented by one-step nucleic acid amplification (OSNA). The latter is a intra-operative molecular assay searching for CK19 mRNA as a surrogate of metastatic cells. Our 3 years experience with OSNA (1122 patients) showed results overlapping those recorded in the same institution with a morphological evaluation (930 patients) of SLN. In detail, the data of OSNA were almost identical to those observed with standard post-operative procedure in terms of patients with positive SLN (30%) and micrometastatic/macrometastatic involvement of SLN (respectively, 38-45 and 62-55%). By contrast, when OSNA was compared to the standard intraoperatory procedure, it was superior in terms of accuracy, prompting the use of this molecular assay as a very valid, and reproducible for intra-operative evaluation of SLN. Further possibilities prompting the use of OSNA range from adhesion to quality control programs, saving of medical time, ability to predict, during surgery, additional nodal metastasis, and molecular bio-banking.

  11. Utility of intraoperative nerve monitoring in thyroid surgery: 20-year experience with 1418 cases.

    PubMed

    Kadakia, Sameep; Mourad, Moustafa; Hu, Shirley; Brown, Ryan; Lee, Thomas; Ducic, Yadranko

    2017-09-01

    The efficacy of intraoperative nerve monitoring is controversial in the literature. This study of a single surgeon's experience seeks to determine if the use of intraoperative nerve monitoring influences recurrent laryngeal nerve injury during thyroid surgery. Six hundred fifty-seven patients with normal pre-operative vocal fold function underwent thyroid surgery without the use of intraoperative nerve monitoring from September 1997 to January 2007, while 761 patients underwent thyroid surgery from February 2007 to February 2016 with routine use of nerve monitoring. Patients were followed for a minimum of 6 months after surgery, and postoperative nerve function was determined by fiberoptic laryngoscopy. A Fisher test was used to determine if nerve injury was statistically different between both groups. In patients operated on without nerve monitoring, 21 patients were found to have postoperative vocal fold paralysis with nine regaining functioning. In patients operated on with nerve monitoring, 27 were found to have vocal fold dysfunction with 17 regaining function. Fisher test analysis, both with and without patients regaining function, showed no difference in nerve injury between groups (p > 0.05, p > 0.05). Intraoperative monitoring during thyroidectomy may not prevent injury to the recurrent laryngeal nerve.

  12. Robotic thyroidectomy learning curve for beginning surgeons with little or no experience of endoscopic surgery.

    PubMed

    Park, Jae Hyun; Lee, Jandee; Hakim, Nor Azham; Kim, Ha Yan; Kang, Sang-Wook; Jeong, Jong Ju; Nam, Kee-Hyun; Bae, Keum-Seok; Kang, Seong Joon; Chung, Woong Youn

    2015-12-01

    This study assessed the results of robotic thyroidectomy by fellowship-trained surgeons in their initial independent practice, and whether standard fellowship training for robotic surgery shortens the learning curve. This prospective cohort study evaluated outcomes in 125 patients who underwent robotic thyroidectomy using gasless transaxillary single-incision technique by 2 recently graduated fellowship-trained surgeons. Learning curves were analyzed by operation time, with proficiency defined as the point at which the slope of the time curve became less steep. Of the 125 patients, 113 underwent robotic less-than-total thyroidectomy, 9 underwent robotic total thyroidectomy and 3 underwent robotic total thyroidectomy with modified radical neck dissection. Mean total times for these 3 operations were 100.8 ± 20.6 minutes, 134.2 ± 38.7 minutes, and 284.7 ± 60.4 minutes, respectively. For both surgeons, the operation times gradually decreased, reaching a plateau after 20 robotic less-than-total thyroidectomies. The surgical learning curve for robotic thyroidectomy performed by recently graduated fellowship-trained surgeons with little or no experience in endoscopic surgery showed excellent results compared with those in a large series of more experienced surgeons. © 2014 Wiley Periodicals, Inc.

  13. Effect of promoter architecture on the cell-to-cell variability in gene expression.

    PubMed

    Sanchez, Alvaro; Garcia, Hernan G; Jones, Daniel; Phillips, Rob; Kondev, Jané

    2011-03-01

    According to recent experimental evidence, promoter architecture, defined by the number, strength and regulatory role of the operators that control transcription, plays a major role in determining the level of cell-to-cell variability in gene expression. These quantitative experiments call for a corresponding modeling effort that addresses the question of how changes in promoter architecture affect variability in gene expression in a systematic rather than case-by-case fashion. In this article we make such a systematic investigation, based on a microscopic model of gene regulation that incorporates stochastic effects. In particular, we show how operator strength and operator multiplicity affect this variability. We examine different modes of transcription factor binding to complex promoters (cooperative, independent, simultaneous) and how each of these affects the level of variability in transcriptional output from cell-to-cell. We propose that direct comparison between in vivo single-cell experiments and theoretical predictions for the moments of the probability distribution of mRNA number per cell can be used to test kinetic models of gene regulation. The emphasis of the discussion is on prokaryotic gene regulation, but our analysis can be extended to eukaryotic cells as well.

  14. Effect of Promoter Architecture on the Cell-to-Cell Variability in Gene Expression

    PubMed Central

    Sanchez, Alvaro; Garcia, Hernan G.; Jones, Daniel; Phillips, Rob; Kondev, Jané

    2011-01-01

    According to recent experimental evidence, promoter architecture, defined by the number, strength and regulatory role of the operators that control transcription, plays a major role in determining the level of cell-to-cell variability in gene expression. These quantitative experiments call for a corresponding modeling effort that addresses the question of how changes in promoter architecture affect variability in gene expression in a systematic rather than case-by-case fashion. In this article we make such a systematic investigation, based on a microscopic model of gene regulation that incorporates stochastic effects. In particular, we show how operator strength and operator multiplicity affect this variability. We examine different modes of transcription factor binding to complex promoters (cooperative, independent, simultaneous) and how each of these affects the level of variability in transcriptional output from cell-to-cell. We propose that direct comparison between in vivo single-cell experiments and theoretical predictions for the moments of the probability distribution of mRNA number per cell can be used to test kinetic models of gene regulation. The emphasis of the discussion is on prokaryotic gene regulation, but our analysis can be extended to eukaryotic cells as well. PMID:21390269

  15. The ATLAS Tier-0: Overview and operational experience

    NASA Astrophysics Data System (ADS)

    Elsing, Markus; Goossens, Luc; Nairz, Armin; Negri, Guido

    2010-04-01

    Within the ATLAS hierarchical, multi-tier computing infrastructure, the Tier-0 centre at CERN is mainly responsible for prompt processing of the raw data coming from the online DAQ system, to archive the raw and derived data on tape, to register the data with the relevant catalogues and to distribute them to the associated Tier-1 centers. The Tier-0 is already fully functional. It has been successfully participating in all cosmic and commissioning data taking since May 2007, and was ramped up to its foreseen full size, performance and throughput for the cosmic (and short single-beam) run periods between July and October 2008. Data and work flows for collision data taking were exercised in several "Full Dress Rehearsals" (FDRs) in the course of 2008. The transition from an expert to a shifter-based system was successfully established in July 2008. This article will give an overview of the Tier-0 system, its data and work flows, and operations model. It will review the operational experience gained in cosmic, commissioning, and FDR exercises during the past year. And it will give an outlook on planned developments and the evolution of the system towards first collision data taking expected now in late Autumn 2009.

  16. Experimental thermodynamics of single molecular motor.

    PubMed

    Toyabe, Shoichi; Muneyuki, Eiro

    2013-01-01

    Molecular motor is a nano-sized chemical engine that converts chemical free energy to mechanical motions. Hence, the energetics is as important as kinetics in order to understand its operation principle. We review experiments to evaluate the thermodynamic properties of a rotational F1-ATPase motor (F1-motor) at a single-molecule level. We show that the F1-motor achieves 100% thermo dynamic efficiency at the stalled state. Furthermore, the motor reduces the internal irreversible heat inside the motor to almost zero and achieves a highly-efficient free energy transduction close to 100% during rotations far from quasistatic process. We discuss the mechanism of how the F1-motor achieves such a high efficiency, which highlights the remarkable property of the nano-sized engine F1-motor.

  17. a Thtee-Dimensional Variational Assimilation Scheme for Satellite Aod

    NASA Astrophysics Data System (ADS)

    Liang, Y.; Zang, Z.; You, W.

    2018-04-01

    A three-dimensional variational data assimilation scheme is designed for satellite AOD based on the IMPROVE (Interagency Monitoring of Protected Visual Environments) equation. The observation operator that simulates AOD from the control variables is established by the IMPROVE equation. All of the 16 control variables in the assimilation scheme are the mass concentrations of aerosol species from the Model for Simulation Aerosol Interactions and Chemistry scheme, so as to take advantage of this scheme in providing comprehensive analyses of species concentrations and size distributions as well as be calculating efficiently. The assimilation scheme can save computational resources as the IMPROVE equation is a quadratic equation. A single-point observation experiment shows that the information from the single-point AOD is effectively spread horizontally and vertically.

  18. Demonstration of charge breeding in a compact room temperature electron beam ion trap

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vorobjev, G.; Sokolov, A.; Herfurth, F.

    2012-05-15

    For the first time, a small room-temperature electron beam ion trap (EBIT), operated with permanent magnets, was successfully used for charge breeding experiments. The relatively low magnetic field of this EBIT does not contribute to the capture of the ions; single-charged ions are only caught by the space charge potential of the electron beam. An over-barrier injection method was used to fill the EBIT's electrostatic trap with externally produced, single-charged potassium ions. Charge states as high as K{sup 19+} were reached after about a 3 s breeding time. The capture and breeding efficiencies up to 0.016(4)% for K{sup 17+} havemore » been measured.« less

  19. A low-energy metal-ion source for primary ion deposition and accelerated ion doping during molecular-beam epitaxy

    NASA Astrophysics Data System (ADS)

    Hasan, M.-A.; Knall, J.; Barnett, S. A.; Rockett, A.; Sundgren, J.-E.

    1987-10-01

    A single-grid electron-impact ultrahigh vacuum (UHV) compatible low-energy ion gun capable of operating with a low vapor pressure solid source material such as In is presented. The gun consists of a single chamber which integrates the functions of an effusion cell, a vapor transport tube, and a glow discharge ionizer. The initial results of experiments designed to study the role of ion/surface interactions during nucleation and the early stages of crystal growth in UHV revealed that, for deposition on amorphous substrates, the use of a partially ionized In(+) beam resulted in a progressive shift towards larger island sizes, a decreased rate of secondary nucleation, and a more uniform island size distribution.

  20. Midterm outcomes of single port thoracoscopic surgery for major pulmonary resection

    PubMed Central

    2017-01-01

    Introduction Single-port thoracoscopic surgery has widened the current minimally invasive surgical techniques toward more less invasive procedures in terms of reducing the number of incisions. However, the current status of oncologic outcome with this technique is not well known for lung cancer surgery. The purpose of this study is to evaluate the oncologic outcomes in early stage lung cancer for impact of the survival outcomes with our experience of conversion to a single-port approach from the conventional three-port approach. Materials and methods Retrospective data of patients who underwent thoracoscopic major lung resection for non-small cell lung cancer between January 2006 and June 2015 were analyzed. Patients’ characteristics, perioperative outcomes, pathologic result, and postoperative follow-up data of thoracoscopic surgery were reviewed and surgical outcomes were compared between conventional three-port (n = 168), two-port (n = 68), and single-port thoracoscopic surgery (n = 203). Results Of the 203 single-port thoracoscopic surgeries, we performed 167 single-port thoracoscopic lobectomy and mediastinal lymph node dissections. During the learning period of each thoracoscopic approach, the mean operation time for single-port thoracoscopic surgery (189±62 min) was not significantly different from those of two-port (175±46 min) and three-port (195±75 min) thoracoscopic lobectomy (p = 0.165). Perioperative outcomes including drain indwelling time (p <0.001), complication (p = 0.185) and conversion event (p = 0.911) were not worsened during learning period with two-port. Midterm survival (p = 0.753) and recurrence free survival (p = 0.656) of single port thoracoscopic lobectomy showed acceptable results compared with two- and three-port approach. Conclusions Single-port thoracoscopic surgery is safe and a feasible option for major lung resection in lung malignancy and this approach following experiences of two-port approach may yield similar oncologic results to those of conventional multi-port approach during thoracoscopic lobectomy. PMID:29136038

  1. Multiple acquisition of magic angle spinning solid-state NMR experiments using one receiver: Application to microcrystalline and membrane protein preparations

    NASA Astrophysics Data System (ADS)

    Gopinath, T.; Veglia, Gianluigi

    2015-04-01

    Solid-state NMR spectroscopy of proteins is a notoriously low-throughput technique. Relatively low-sensitivity and poor resolution of protein samples require long acquisition times for multidimensional NMR experiments. To speed up data acquisition, we developed a family of experiments called Polarization Optimized Experiments (POE), in which we utilized the orphan spin operators that are discarded in classical multidimensional NMR experiments, recovering them to allow simultaneous acquisition of multiple 2D and 3D experiments, all while using conventional probes with spectrometers equipped with one receiver. POE allow the concatenation of multiple 2D or 3D pulse sequences into a single experiment, thus potentially combining all of the aforementioned advances, boosting the capability of ssNMR spectrometers at least two-fold without the addition of any hardware. In this perspective, we describe the first generation of POE, such as dual acquisition MAS (or DUMAS) methods, and then illustrate the evolution of these experiments into MEIOSIS, a method that enables the simultaneous acquisition of multiple 2D and 3D spectra. Using these new pulse schemes for the solid-state NMR investigation of biopolymers makes it possible to obtain sequential resonance assignments, as well as distance restraints, in about half the experimental time. While designed for acquisition of heteronuclei, these new experiments can be easily implemented for proton detection and coupled with other recent advancements, such as dynamic nuclear polarization (DNP), to improve signal to noise. Finally, we illustrate the application of these methods to microcrystalline protein preparations as well as single and multi-span membrane proteins reconstituted in lipid membranes.

  2. Multiple acquisition of magic angle spinning solid-state NMR experiments using one receiver: application to microcrystalline and membrane protein preparations.

    PubMed

    Gopinath, T; Veglia, Gianluigi

    2015-04-01

    Solid-state NMR spectroscopy of proteins is a notoriously low-throughput technique. Relatively low-sensitivity and poor resolution of protein samples require long acquisition times for multidimensional NMR experiments. To speed up data acquisition, we developed a family of experiments called Polarization Optimized Experiments (POE), in which we utilized the orphan spin operators that are discarded in classical multidimensional NMR experiments, recovering them to allow simultaneous acquisition of multiple 2D and 3D experiments, all while using conventional probes with spectrometers equipped with one receiver. POE allow the concatenation of multiple 2D or 3D pulse sequences into a single experiment, thus potentially combining all of the aforementioned advances, boosting the capability of ssNMR spectrometers at least two-fold without the addition of any hardware. In this perspective, we describe the first generation of POE, such as dual acquisition MAS (or DUMAS) methods, and then illustrate the evolution of these experiments into MEIOSIS, a method that enables the simultaneous acquisition of multiple 2D and 3D spectra. Using these new pulse schemes for the solid-state NMR investigation of biopolymers makes it possible to obtain sequential resonance assignments, as well as distance restraints, in about half the experimental time. While designed for acquisition of heteronuclei, these new experiments can be easily implemented for proton detection and coupled with other recent advancements, such as dynamic nuclear polarization (DNP), to improve signal to noise. Finally, we illustrate the application of these methods to microcrystalline protein preparations as well as single and multi-span membrane proteins reconstituted in lipid membranes. Copyright © 2015 Elsevier Inc. All rights reserved.

  3. Multiple Acquisition of Magic Angle Spinning Solid-State NMR Experiments Using One Receiver: Application to Microcrystalline and Membrane Protein Preparations

    PubMed Central

    Gopinath, T.; Veglia, Gianluigi

    2015-01-01

    Solid-State NMR spectroscopy of proteins is a notoriously low-throughput technique. Relatively low-sensitivity and poor resolution of protein samples require long acquisition times for multidimensional NMR experiments. To speed up data acquisition, we developed a family of experiments called Polarization Optimized Experiments (POE), in which we utilized the orphan spin operators that are discarded in classical multidimensional NMR experiments, recovering them to allow simultaneous acquisition of multiple 2D and 3D experiments, all while using conventional probes with spectrometers equipped with one receiver. POEs allow the concatenation of multiple 2D or 3D pulse sequences into a single experiment, thus potentially combining all of the aforementioned advances, boosting the capability of ssNMR spectrometers at least two-fold without the addition of any hardware. In this Perspective, we describe the first generation of POEs, such as dual acquisition MAS (or DUMAS) methods, and then illustrate the evolution of these experiments into MEIOSIS, a method that enables the simultaneous acquisition of multiple 2D and 3D spectra. Using these new pulse schemes for the solid-state NMR investigation of biopolymers makes it possible to obtain sequential resonance assignments, as well as distance restraints, in about half the experimental time. While designed for acquisition of heteronuclei, these new experiments can be easily implemented for proton detection and coupled with other recent advancements, such as dynamic polarization, to improve signal to noise. Finally, we illustrate the application of these methods to microcrystalline protein preparations as well as single and multi-span membrane proteins reconstituted in lipid membranes. PMID:25797011

  4. Technical results and effects of operator experience on uterine artery embolization for fibroids: the Ontario Uterine Fibroid Embolization Trial.

    PubMed

    Pron, Gaylene; Bennett, John; Common, Andrew; Sniderman, Kenneth; Asch, Murray; Bell, Stuart; Kozak, Roman; Vanderburgh, Leslie; Garvin, Greg; Simons, Martin; Tran, Cuong; Kachura, John

    2003-05-01

    To document the technical results and spectrum of practice of uterine artery embolization (UAE) for fibroids in the health care setting in Canada. The effects of interventional radiologist's (IR's) experience with UAE on procedure and fluoroscopy time were also investigated. The study involved a multicenter prospective single-arm clinical treatment trial and included the practices of 11 IRs at eight university-affiliated teaching and community hospitals. Vascular access with percutaneous femoral artery approach was followed by transcatheter delivery of polyvinyl alcohol (PVA) particles into uterine arteries with fluoroscopic guidance. Technical success, complications, procedural time, fluoroscopy time, and effects of operator experience were outcomes analyzed. Between November 1998 and November 2000, 570 embolization procedures were performed in 555 patients. UAE was bilaterally successful in 97% (95% CI: 95%-98%). Variant anatomy was the most common reason for failure to embolize bilaterally. The procedural complication rate was 5.3% (95% CI: 3.6%-7.4%). Of the 30 events, three involved major complications (one seizure and two allergic reactions) that resulted in additional care or extended hospital stay. Procedure time and fluoroscopy time averaged 61 minutes (95% CI; 58-63 minutes) and 18.9 minutes (95% CI; 18-19.8) and varied significantly among IRs (P <.001; P <.001). The average 27% reduction in procedure time (20 minutes; P <.001) and 24% reduction in fluoroscopy time (5.1 minutes; P <.001) with increasing UAE experience were significant. A high level of technical success with few complications was obtained with a variety of operators in diverse practice settings. Increased experience in UAE significantly reduced procedure and fluoroscopy time.

  5. Identification of risk factors for mucosal injury during laparoscopic Heller myotomy for achalasia.

    PubMed

    Tsuboi, Kazuto; Omura, Nobuo; Yano, Fumiaki; Hoshino, Masato; Yamamoto, Se-Ryung; Akimoto, Shusuke; Masuda, Takahiro; Kashiwagi, Hideyuki; Yanaga, Katsuhiko

    2016-02-01

    Mucosal injury during myotomy is the most frequent complication seen with the Heller-Dor procedure for achalasia. The present study aimed to examine risk factors for such mucosal injury during this procedure. This was a retrospective analysis of patients who underwent the laparoscopic Heller-Dor procedure for achalasia at a single facility. Variables for evaluation included patient characteristics, preoperative pathophysiological findings, and surgeon's operative experience. Logistic regression was used to identify risk factors. We also examined surgical outcomes and the degree of patient satisfaction in relation to intraoperative mucosal injury. Four hundred thirty-five patients satisfied study criteria. Intraoperative mucosal injury occurred in 67 patients (15.4%). In univariate analysis, mucosal injury was significantly associated with the patient age ≥60 years, disease history ≥10 years, prior history of cardiac diseases, preoperative esophageal transverse diameter ≥80 mm, and surgeon's operative experience with fewer than five cases. In multivariate analysis involving these factors, the following variables were identified as risk factors: age ≥60 years, esophageal transverse diameter ≥80 mm, and surgeon's operative experience with fewer than five cases. The mucosal injury group had significant extension of the operative time and increased blood loss. However, there were no significant differences between the two groups in the incidence of reflux esophagitis or the degree of symptom alleviation postoperatively. The fragile esophagus caused by advanced patient age and/or dilatation were risk factor for mucosal injury during laparoscopic Heller-Dor procedure. And novice surgeon was also identified as an isolated risk factor for mucosal injury.

  6. Proximal Leakage After Laparoscopic Sleeve Gastrectomy: an Analysis of Preoperative and Operative Predictors on 1738 Consecutive Procedures.

    PubMed

    Cesana, Giovanni; Cioffi, Stefano; Giorgi, Riccardo; Villa, Roberta; Uccelli, Matteo; Ciccarese, Francesca; Castello, Giorgio; Scotto, Bruno; Olmi, Stefano

    2018-03-01

    The purpose of this paper was to search for predictive factors for proximal leakage after laparoscopic sleeve gastrectomy (LSG) in a large cohort from a single referral center. One thousand seven hundred and thirty-eight patients, collected in a prospectively held database from 2008 to 2016, were retrospectively analyzed. The correlation between postoperative leakage and both preoperative (age, gender, height, weight, BMI, and obesity-related morbidities) and operative variables (the distance from pylorus at which the gastric section was started, operative time, experience of surgeons who performed the LSG, and the surgical materials used) was analyzed. The experience of the surgeons was calculated in the number of LSGs performed. The surgical materials considered were stapler, cartridges, and reinforcement of the suture. Proximal leakage was observed in 45 patients out of 1738 (2.6%). No correlation was found between leakage and the preoperative variables analyzed. The operative variables that were found to be associated with lower incidence of leakage at the multivariate analysis (p < 0.05) were the reinforcement of the staple line (or overriding suture or buttressing materials) and the experience of the surgeons. A distance of less than 2 cm from the pylorus resulted to be significantly related to a higher incidence of fistula at the univariate analysis. In this large consecutive cohort study of LSG, proximal staple line reinforcement (buttress material or suture) reduced the risk of a leak. The risk of a proximal leak was much higher in the surgeons first 100 cases, which has implications for training and supervision during this "learning curve" period.

  7. Impact of Remotely Piloted Aircraft Type on Operations Using the Same Control Station: A Natural Experiment

    DTIC Science & Technology

    2013-07-01

    heterogeneous RPA, either individually or simultaneously from a single control station. Also, emerging RPA system-of-systems architectures are...environment 1 1.4 0 0.0 >0.999 Technological environment 25 36.2 6 31.6 0.707 Cognitive factors 27 39.1 12 63.2 0.062 Psycho ...errors 0.460 4 36.86 Physical environment 0.775 Physical/mental limitations 0.722 5 45.27 Psycho -behavioral factors 0.760 Inadequate supervision

  8. [Development of automatic urine monitoring system].

    PubMed

    Wei, Liang; Li, Yongqin; Chen, Bihua

    2014-03-01

    An automatic urine monitoring system is presented to replace manual operation. The system is composed of the flow sensor, MSP430f149 single chip microcomputer, human-computer interaction module, LCD module, clock module and memory module. The signal of urine volume is captured when the urine flows through the flow sensor and then displayed on the LCD after data processing. The experiment results suggest that the design of the monitor provides a high stability, accurate measurement and good real-time, and meets the demand of the clinical application.

  9. Single service point: it's all in the design.

    PubMed

    Bradigan, Pamela S; Rodman, Ruey L

    2008-01-01

    "Design thinking" principles from a leading design firm, IDEO, were key elements in the planning process for a one-desk service model, the ASK Desk, at the John A. Prior Health Sciences Library. The library administration and staff employed the methodology to enhance customer experiences, meet technology challenges, and compete in a changing education environment. The most recent renovations demonstrate how the principles were applied. The concept of "continuous design thinking" is important in the library's daily operations to serve customers most effectively.

  10. Optimal Synthesis of the Joint Unitary Evolutions

    NASA Astrophysics Data System (ADS)

    Wei, Hai-Rui; Alsaedi, Ahmed; Hobiny, Aatef; Deng, Fu-Guo; Hu, Hui; Zhang, Dun

    2018-07-01

    Joint unitary operations play a central role in quantum communication and computation. We give a quantum circuit for implementing a type of unconstructed useful joint unitary evolutions in terms of controlled-NOT (CNOT) gates and single-qubit rotations. Our synthesis is optimal and possible in experiment. Two CNOT gates and seven R x , R y or R z rotations are required for our synthesis, and the arbitrary parameter contained in the evolutions can be controlled by local Hamiltonian or external fields.

  11. SiPM timing characteristics under conditions of a large background for lidars

    NASA Astrophysics Data System (ADS)

    Antonova, A. M.; Kaplin, V. A.

    2018-01-01

    Silicon photomultipliers (SiPM) have found their use in various fields of industry and scientific experiments. This paper considers study of the SiPM possibility to detect low-intensity light pulses (down to single photons) under high-intensity background illumination. This may be useful for the development of laser rangefinders operating under natural light using SiPM as crucial photosensor. Moreover, the presented data describes some physical properties of LIDAR with SiPM under radiation exposure, which always affects its intrinsic noise.

  12. Optimal Synthesis of the Joint Unitary Evolutions

    NASA Astrophysics Data System (ADS)

    Wei, Hai-Rui; Alsaedi, Ahmed; Hobiny, Aatef; Deng, Fu-Guo; Hu, Hui; Zhang, Dun

    2018-03-01

    Joint unitary operations play a central role in quantum communication and computation. We give a quantum circuit for implementing a type of unconstructed useful joint unitary evolutions in terms of controlled-NOT (CNOT) gates and single-qubit rotations. Our synthesis is optimal and possible in experiment. Two CNOT gates and seven R x , R y or R z rotations are required for our synthesis, and the arbitrary parameter contained in the evolutions can be controlled by local Hamiltonian or external fields.

  13. Control/display trade-off study for single-pilot instrument flight rule operations

    NASA Technical Reports Server (NTRS)

    Hoh, R.

    1983-01-01

    The objectives were to determine minimum autopilot functions and displays required to keep pilot workload at an acceptable level; to determine what constitutes an acceptable level of workload; to identify critical tasks; and to suggest specific experiments required to refine conclusions. It was determined that workload relief is derived from basic stability augmentation; that complex autopilots can lead to serious blunders; and that displays need to enhance positional awareness and minimize the likelihood of false hypothesis.

  14. A hierarchical preconditioner for the electric field integral equation on unstructured meshes based on primal and dual Haar bases

    NASA Astrophysics Data System (ADS)

    Adrian, S. B.; Andriulli, F. P.; Eibert, T. F.

    2017-02-01

    A new hierarchical basis preconditioner for the electric field integral equation (EFIE) operator is introduced. In contrast to existing hierarchical basis preconditioners, it works on arbitrary meshes and preconditions both the vector and the scalar potential within the EFIE operator. This is obtained by taking into account that the vector and the scalar potential discretized with loop-star basis functions are related to the hypersingular and the single layer operator (i.e., the well known integral operators from acoustics). For the single layer operator discretized with piecewise constant functions, a hierarchical preconditioner can easily be constructed. Thus the strategy we propose in this work for preconditioning the EFIE is the transformation of the scalar and the vector potential into operators equivalent to the single layer operator and to its inverse. More specifically, when the scalar potential is discretized with star functions as source and testing functions, the resulting matrix is a single layer operator discretized with piecewise constant functions and multiplied left and right with two additional graph Laplacian matrices. By inverting these graph Laplacian matrices, the discretized single layer operator is obtained, which can be preconditioned with the hierarchical basis. Dually, when the vector potential is discretized with loop functions, the resulting matrix can be interpreted as a hypersingular operator discretized with piecewise linear functions. By leveraging on a scalar Calderón identity, we can interpret this operator as spectrally equivalent to the inverse single layer operator. Then we use a linear-in-complexity, closed-form inverse of the dual hierarchical basis to precondition the hypersingular operator. The numerical results show the effectiveness of the proposed preconditioner and the practical impact of theoretical developments in real case scenarios.

  15. Operation and biasing for single device equivalent to CMOS

    DOEpatents

    Welch, James D.

    2001-01-01

    Disclosed are semiconductor devices including at least one junction which is rectifying whether the semiconductor is caused to be N or P-type, by the presence of field induced carriers. In particular, inverting and non-inverting gate voltage channel induced semiconductor single devices with operating characteristics similar to conventional multiple device CMOS systems, which can be operated as modulators, are disclosed as are a non-latching SCR and an approach to blocking parasitic currents. Operation of the gate voltage channel induced semiconductor single devices with operating characteristics similar to multiple device CMOS systems under typical bias schemes is described, and simple demonstrative five mask fabrication procedures for the inverting and non-inverting gate voltage channel induced semiconductor single devices with operating characteristics similar to multiple device CMOS systems are also presented.

  16. Issues in the inverse modeling of a soil infiltration process

    NASA Astrophysics Data System (ADS)

    Kuraz, Michal; Jacka, Lukas; Leps, Matej

    2017-04-01

    This contribution addresses issues in evaluation of the soil hydraulic parameters (SHP) from the Richards equation based inverse model. The inverse model was representing single ring infiltration experiment on mountainous podzolic soil profile, and was searching for the SHP parameters of the top soil layer. Since the thickness of the top soil layer is often much lower than the depth required to embed the single ring or Guelph permeameter device, the SHPs for the top soil layer are very difficult to measure directly. The SHPs for the top soil layer were therefore identified here by inverse modeling of the single ring infiltration process, where, especially, the initial unsteady part of the experiment is expected to provide very useful data for evaluating the retention curve parameters (excluding the residual water content) and the saturated hydraulic conductivity. The main issue, which is addressed in this contribution, is the uniqueness of the Richards equation inverse model. We tried to answer the question whether is it possible to characterize the unsteady infiltration experiment with a unique set of SHPs values, and whether are all SHP parameters vulnerable with the non-uniqueness. Which is an important issue, since we could further conclude whether the popular gradient methods are appropriate here. Further the issues in assigning the initial and boundary condition setup, the influence of spatial and temporal discretization on the values of the identified SHPs, and the convergence issues with the Richards equation nonlinear operator during automatic calibration procedure are also covered here.

  17. Hydrodynamic and material properties experiments using pulsed power techniques

    NASA Astrophysics Data System (ADS)

    Reinovsky, R. E.; Trainor, R. J.

    2000-04-01

    Within the last five years, a new approach to the exploration of dynamic material properties and advanced hydrodynamics at extreme conditions has joined the traditional techniques of high velocity guns and explosives. This new application uses electromagnetic energy to accelerate solid density material to produce shocks in a cylindrical target. The principal tool for producing high energy density environments is the high precision, magnetically imploded, near-solid density cylindrical liner. The most attractive pulsed power system for driving such experiments is an ultrahigh current, low impedance, microsecond time scale source that is economical both to build and to operate. Two families of pulsed power systems can be applied to drive such experiments. The 25-MJ Atlas capacitor bank system currently under construction at Los Alamos is the first system of its scale specifically designed to drive high precision solid liners. Delivering 30 MA, Atlas will provide liner velocities 12-15 km/sec and kinetic energies of 1-2 MJ/cm with extensive diagnostics and excellent reproducibility. Explosive flux compressor technology provides access to currents exceeding 100 MA producing liner velocities above 25 km/sec and kinetic energies of 5-20 MJ/cm in single shot operations

  18. The development of a Space Shuttle Research Animal Holding Facility

    NASA Technical Reports Server (NTRS)

    Jagow, R. B.

    1980-01-01

    The ability to maintain the well being of experiment animals is of primary importance to the successful attainment of life sciences flight experiment goals. To assist scientists in the conduct of life sciences flight experiments, a highly versatile Research Animal Holding Facility (RAHF) is being developed for use on Space Shuttle/Spacelab missions. This paper describes the design of the RAHF system, which in addition to providing general housing for various animal species, approximating the environment found in ground based facilities, is designed to minimize disturbances of the specimens by vehicle and mission operations. Life-sustaining capabilities such as metabolic support and environmental control are provided. RAHF is reusable and is a modular concept to accommodate animals of different sizes. The basic RAHF system will accommodate a combination of 24 500-g rats or 144 mice or a mixed number of rats and mice. An alternative design accommodates four squirrel monkeys. The entire RAHF system is housed in a single ESA rack. The animal cages are in drawers which are removable for easy access to the animals. Each cage contains a waste management system, a feeding system and a watering system all of which will operate in zero or one gravity.

  19. Estimating the location of baleen whale calls using dual streamers to support mitigation procedures in seismic reflection surveys.

    PubMed

    Abadi, Shima H; Tolstoy, Maya; Wilcock, William S D

    2017-01-01

    In order to mitigate against possible impacts of seismic surveys on baleen whales it is important to know as much as possible about the presence of whales within the vicinity of seismic operations. This study expands on previous work that analyzes single seismic streamer data to locate nearby calling baleen whales with a grid search method that utilizes the propagation angles and relative arrival times of received signals along the streamer. Three dimensional seismic reflection surveys use multiple towed hydrophone arrays for imaging the structure beneath the seafloor, providing an opportunity to significantly improve the uncertainty associated with streamer-generated call locations. All seismic surveys utilizing airguns conduct visual marine mammal monitoring surveys concurrent with the experiment, with powering-down of seismic source if a marine mammal is observed within the exposure zone. This study utilizes data from power-down periods of a seismic experiment conducted with two 8-km long seismic hydrophone arrays by the R/V Marcus G. Langseth near Alaska in summer 2011. Simulated and experiment data demonstrate that a single streamer can be utilized to resolve left-right ambiguity because the streamer is rarely perfectly straight in a field setting, but dual streamers provides significantly improved locations. Both methods represent a dramatic improvement over the existing Passive Acoustic Monitoring (PAM) system for detecting low frequency baleen whale calls, with ~60 calls detected utilizing the seismic streamers, zero of which were detected using the current R/V Langseth PAM system. Furthermore, this method has the potential to be utilized not only for improving mitigation processes, but also for studying baleen whale behavior within the vicinity of seismic operations.

  20. Estimating the location of baleen whale calls using dual streamers to support mitigation procedures in seismic reflection surveys

    PubMed Central

    Abadi, Shima H.; Tolstoy, Maya; Wilcock, William S. D.

    2017-01-01

    In order to mitigate against possible impacts of seismic surveys on baleen whales it is important to know as much as possible about the presence of whales within the vicinity of seismic operations. This study expands on previous work that analyzes single seismic streamer data to locate nearby calling baleen whales with a grid search method that utilizes the propagation angles and relative arrival times of received signals along the streamer. Three dimensional seismic reflection surveys use multiple towed hydrophone arrays for imaging the structure beneath the seafloor, providing an opportunity to significantly improve the uncertainty associated with streamer-generated call locations. All seismic surveys utilizing airguns conduct visual marine mammal monitoring surveys concurrent with the experiment, with powering-down of seismic source if a marine mammal is observed within the exposure zone. This study utilizes data from power-down periods of a seismic experiment conducted with two 8-km long seismic hydrophone arrays by the R/V Marcus G. Langseth near Alaska in summer 2011. Simulated and experiment data demonstrate that a single streamer can be utilized to resolve left-right ambiguity because the streamer is rarely perfectly straight in a field setting, but dual streamers provides significantly improved locations. Both methods represent a dramatic improvement over the existing Passive Acoustic Monitoring (PAM) system for detecting low frequency baleen whale calls, with ~60 calls detected utilizing the seismic streamers, zero of which were detected using the current R/V Langseth PAM system. Furthermore, this method has the potential to be utilized not only for improving mitigation processes, but also for studying baleen whale behavior within the vicinity of seismic operations. PMID:28199400

  1. Processing LHC data in the UK

    PubMed Central

    Colling, D.; Britton, D.; Gordon, J.; Lloyd, S.; Doyle, A.; Gronbech, P.; Coles, J.; Sansum, A.; Patrick, G.; Jones, R.; Middleton, R.; Kelsey, D.; Cass, A.; Geddes, N.; Clark, P.; Barnby, L.

    2013-01-01

    The Large Hadron Collider (LHC) is one of the greatest scientific endeavours to date. The construction of the collider itself and the experiments that collect data from it represent a huge investment, both financially and in terms of human effort, in our hope to understand the way the Universe works at a deeper level. Yet the volumes of data produced are so large that they cannot be analysed at any single computing centre. Instead, the experiments have all adopted distributed computing models based on the LHC Computing Grid. Without the correct functioning of this grid infrastructure the experiments would not be able to understand the data that they have collected. Within the UK, the Grid infrastructure needed by the experiments is provided by the GridPP project. We report on the operations, performance and contributions made to the experiments by the GridPP project during the years of 2010 and 2011—the first two significant years of the running of the LHC. PMID:23230163

  2. Neutral null models for diversity in serial transfer evolution experiments.

    PubMed

    Harpak, Arbel; Sella, Guy

    2014-09-01

    Evolution experiments with microorganisms coupled with genome-wide sequencing now allow for the systematic study of population genetic processes under a wide range of conditions. In learning about these processes in natural, sexual populations, neutral models that describe the behavior of diversity and divergence summaries have played a pivotal role. It is therefore natural to ask whether neutral models, suitably modified, could be useful in the context of evolution experiments. Here, we introduce coalescent models for polymorphism and divergence under the most common experimental evolution assay, a serial transfer experiment. This relatively simple setting allows us to address several issues that could affect diversity patterns in evolution experiments, whether selection is operating or not: the transient behavior of neutral polymorphism in an experiment beginning from a single clone, the effects of randomness in the timing of cell division and noisiness in population size in the dilution stage. In our analyses and discussion, we emphasize the implications for experiments aimed at measuring diversity patterns and making inferences about population genetic processes based on these measurements. © 2014 The Author(s). Evolution © 2014 The Society for the Study of Evolution.

  3. A Single Institution Review of Initial Application of a 5-mm Stapler

    PubMed Central

    Zens, Tiffany J.; Kohler, Jonathan E.; Le, Hau D.; Nichol, Peter F.; Leys, Charles M.

    2016-01-01

    Abstract Background: Operating in small spaces presents physical constraints that can be even more challenging in minimally invasive operations. Recently, a 5-mm stapler was approved for use in general surgery and pediatric surgery. Here, we present our initial experience using the 5-mm stapler in pediatric general surgery. Materials and Methods: A retrospective chart review was conducted to identify cases using the 5-mm stapler at our institution. Demographic data included age (in months) and weight (in kilograms). Operative data included indication for use, number of loads used, complications related to 5-mm stapler use, and interventions to address complications. A second review focused on patients undergoing the same operations, but using a 10-mm stapler. Results: A total of 60 staple loads were deployed in 32 procedures. There were four adverse outcomes, all recognized intraoperatively. One bleed resulted from application on irradiated tissue and another bleed from application to a small noninflamed mesoappendix. A bronchial staple line leak resulted from improper stapler loading, and a bowel anastomosis leak was oversewn with a single stitch. When compared with 32 matched cases using a 10-mm stapler, there was no difference in age (5-mm = 39.11 months, 10-mm = 50.21 months, P = .49) or weight (5-mm = 16.34 kg, 10-mm = 19.93 kg, P = .51). A total of 60 staple applications were used, with one bleed noted. There was no significant difference in overall complication rate (5-mm rate = 4/60, 10-mm rate = 1/60; P = .36). Conclusion: Our initial experience suggests that although there were more complications with the 5-mm stapler, there is no statistically significant difference in complication rates when compared with the 10-mm stapler. Furthermore, the 5-mm stapler complications can be corrected with device training and proper patient selection. In appropriately selected pediatric surgery cases with size limitations, the 5-mm stapler can be used to minimize the invasiveness of the operation. PMID:27398952

  4. Summary of Group Development and Testing for Single Shell Tank Closure at Hanford

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Harbour, John, R.

    2005-04-28

    This report is a summary of the bench-scale and large scale experimental studies performed by Savannah River National Laboratory for CH2M HILL to develop grout design mixes for possible use in producing fill materials as a part of Tank Closure of the Single-Shell Tanks at Hanford. The grout development data provided in this report demonstrates that these design mixes will produce fill materials that are ready for use in Hanford single shell tank closure. The purpose of this report is to assess the ability of the proposed grout specifications to meet the current requirements for successful single shell tank closuremore » which will include the contracting of services for construction and operation of a grout batch plant. The research and field experience gained by SRNL in the closure of Tanks 17F and 20F at the Savannah River Site was leveraged into the grout development efforts for Hanford. It is concluded that the three Hanford grout design mixes provide fill materials that meet the current requirements for successful placement. This conclusion is based on the completion of recommended testing using Hanford area materials by the operators of the grout batch plant. This report summarizes the regulatory drivers and the requirements for grout mixes as tank fill material. It is these requirements for both fresh and cured grout properties that drove the development of the grout formulations for the stabilization, structural and capping layers.« less

  5. Dynamic Response during PEM Fuel Cell Loading-up

    PubMed Central

    Pei, Pucheng; Yuan, Xing; Gou, Jun; Li, Pengcheng

    2009-01-01

    A study on the effects of controlling and operating parameters for a Proton Exchange Membrane (PEM) fuel cell on the dynamic phenomena during the loading-up process is presented. The effect of the four parameters of load-up amplitudes and rates, operating pressures and current levels on gas supply or even starvation in the flow field is analyzed based accordingly on the transient characteristics of current output and voltage. Experiments are carried out in a single fuel cell with an active area of 285 cm2. The results show that increasing the loading-up amplitude can inevitably increase the possibility of gas starvation in channels when a constant flow rate has been set for the cathode; With a higher operating pressure, the dynamic performance will be improved and gas starvations can be relieved. The transient gas supply in the flow channel during two loading-up mode has also been discussed. The experimental results will be helpful for optimizing the control and operation strategies for PEM fuel cells in vehicles.

  6. The Tri-lab Tantalum Strength Consortium

    NASA Astrophysics Data System (ADS)

    Flicker, Dawn G.; Arsenlis, Thomas A.; Austin, Ryan; Barton, Nathan R.; Benage, John F.; Bronkhorst, Curt A.; Brown, Justin L.; Brown, Staci L.; Buttler, William T.; Shen, Shuh-Rong; Dattelbaum, Dana M.; Fensin, Sayu J.; Gray, George T., III; Lane, J. Matthew D.; Lim, Hojun; Luscher, D. J.; Mattsson, Thomas R.; McNabb, Dennis P.; Remington, Bruce A.; Park, Hye-Sook; Prisbrey, Shon T.; Prime, Michael B.; Scharff, Robert J.; Schraad, Mark W.; Sun, Amy C.

    2017-06-01

    A Tri-lab consortium of experimentalists and theorists at SNL, LLNL, and LANL is joining forces to better understand tantalum strength across an unprecedented range of loading conditions. The team is collecting and comparing tantalum strength data from Hopkinson bar, Taylor cylinder, guns, Z, Omega and the NIF. These experiments, all using Ta from a single lot, span pressures from tenths to hundreds of GPa and strain rates from 103 to 107. New experiments are underway to provide more overlap between the platforms. The experiments are being simulated with a variety of models in order to determine which processes are important under which conditions. The presentation will show results to date. Sandia is a multi-program laboratory operated by Sandia Corporation, a Lockheed Martin Company, for the United States Department of Energy under contract DE-AC04-94AL85000.

  7. Photocatalytic destruction of chlorinated solvents with solar energy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pacheco, J.; Prairie, M.; Yellowhorse, L.

    1990-01-01

    Sandia National Laboratories and the Solar Energy Research Institute are developing a photocatalytic process to destroy organic contaminants in water. Tests with common water pollutants are being conducted at Sandia's Solar Thermal Test Facility using a near commercial-scale single-axis tracking parabolic trough system with glass pipe mounted at its focus. Experiments at this scale provide verification of laboratory studies and allow examination of design and operation issues at a real-life scale. The catalyst, titanium dioxide (TiO{sub 2}), is a harmless material found in paint, cosmetics and toothpaste. Experiments were conducted to determine the effect of key process parameters on destructionmore » rates of two chlorinated organic compounds which are common water pollutants: trichloroethylene and trichloroethane. In this paper, we summarize the engineering-scale results of these experiments and analyses. 21 refs., 8 figs.« less

  8. Exploiting multicore compute resources in the CMS experiment

    NASA Astrophysics Data System (ADS)

    Ramírez, J. E.; Pérez-Calero Yzquierdo, A.; Hernández, J. M.; CMS Collaboration

    2016-10-01

    CMS has developed a strategy to efficiently exploit the multicore architecture of the compute resources accessible to the experiment. A coherent use of the multiple cores available in a compute node yields substantial gains in terms of resource utilization. The implemented approach makes use of the multithreading support of the event processing framework and the multicore scheduling capabilities of the resource provisioning system. Multicore slots are acquired and provisioned by means of multicore pilot agents which internally schedule and execute single and multicore payloads. Multicore scheduling and multithreaded processing are currently used in production for online event selection and prompt data reconstruction. More workflows are being adapted to run in multicore mode. This paper presents a review of the experience gained in the deployment and operation of the multicore scheduling and processing system, the current status and future plans.

  9. SPACEHAB: A giant step in the commercial development of space

    NASA Astrophysics Data System (ADS)

    Shepard, James E.

    SPACEHAB is a privately developed and operated system offering customers a crew-tended microgravity environment for experimentation and product development. The first SPACEHAB flight module was delivered to the SPACEHAB Payload Processing Facility (SPPF) in Florida and 22 experiments are being integrated for an April 1993 mission. SPACEHAB modules are flown in the forward quarter-bay of the NASA Orbiter and are supported by two crew members. The paylaod accommodations include up to 61 experiment lockers, double and single racks and standard mounting plates for mounting unique payload containers directly to the module structure. Experiments designed for the Orbiter mid-deck, Spacelab or Space Station Freedom can be flown in SPACEHAB. The 24-month integration cycle is currently the shortest for any crew-tended carrier; a goal of 18 months is being actively pursued.

  10. Mod-2 wind turbine field operations experiment

    NASA Technical Reports Server (NTRS)

    Gordon, L. H.

    1985-01-01

    The three-machine, 7.5 MW Goodnoe Hills located near Goldendale, Washington and is now in a research/experimental operations phase that offers a unique opportunity to study the effects of single and multiple wind turbines interacting with each other, the power grid; and the environment. Following a brief description of the turbine and project history, this paper addresses major problem areas and research and development test results. Field operations, both routine and nonroutine, are discussed. Routine operation to date has produced over 13,379,000 KWh of electrical energy during 11,064 hr of rotation. Nonroutine operation includes suspended activities caused by a crack in the low speed shaft that necessitated a redesign and reinstallation of this assembly on all three turbines. With the world's largest cluster back in full operation, two of the turbines will be operated over the next years to determine their value as energy producer. The third unit will be used primarily for conducting research tests requiring configuration changes to better understand the wind turbine technology. Technical areas summarized pertain to system performance and enhancements. Specific research tests relating to acoustics, TV interference, and wake effects conclude the paper.

  11. Optimal entangling operations between deterministic blocks of qubits encoded into single photons

    NASA Astrophysics Data System (ADS)

    Smith, Jake A.; Kaplan, Lev

    2018-01-01

    Here, we numerically simulate probabilistic elementary entangling operations between rail-encoded photons for the purpose of scalable universal quantum computation or communication. We propose grouping logical qubits into single-photon blocks wherein single-qubit rotations and the controlled-not (cnot) gate are fully deterministic and simple to implement. Interblock communication is then allowed through said probabilistic entangling operations. We find a promising trend in the increasing probability of successful interblock communication as we increase the number of optical modes operated on by our elementary entangling operations.

  12. 75 FR 50707 - Drawbridge Operation Regulation; Curtis Creek, Baltimore, MD

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-17

    ... double-leaf bascule drawbridge, has requested a temporary deviation from the current general operating... half of the draw spans to single-leaf operation. The drawbridge will operate as follows: (1) Closed to..., vessels openings will be provided if at least 48 hours advance notice is given; (2) Single leaf operation...

  13. Transabdominal wall deployment for instruments, lights, and micromotors using the concept of secured independent tools.

    PubMed

    Tsin, Daniel A; Davila, Fausto; Dominguez, Guillermo; Tinelli, Andrea; Davila, Martha R

    2012-05-01

    Use of secured independent tools (SIT) is changing the laparoscopy paradigm, which involves the use of instruments inside the abdominal cavity that are operated via a port that is larger in diameter than the instrument itself. However, in SIT instead of ports we used filaments or cables. Here we describe a modified SIT for use in the introduction of sutures or cables inside the peritoneum. Cables or sutures are passed through a tunnel made by an intravenous catheter and then exteriorized via a 12-mm port for tying, plugging (attaching), or connecting to different types of devices such as an endoscopic bulldog, alligator clamps, lights, and micromotors. These devices are introduced inside the abdomen and remotely operated with cables or filaments. The use of SIT is not limited to laparoscopy; it was successfully used in clinical experiences of single-port and single-incision laparoscopy and could facilitate natural orifice surgery. The technique offers a good force for traction, retraction, and mobilization. In addition, it has transmission capabilities for cameras and may facilitate the placement of wired microrobotics.

  14. Neutron Particle Effects on a Quad-Redundant Flight Control Computer

    NASA Technical Reports Server (NTRS)

    Eure, Kenneth; Belcastro, Celeste M.; Gray, W Steven; Gonzalex, Oscar

    2003-01-01

    This paper describes a single-event upset experiment performed at the Los Alamos National Laboratory. A closed-loop control system consisting of a Quad-Redundant Flight Control Computer (FCC) and a B737 simulator was operated while the FCC was exposed to a neutron beam. The purpose of this test was to analyze the effects of neutron bombardment on avionics control systems operating at altitudes where neutron strikes are probable. The neutron energy spectrum produced at the Los Alamos National Laboratory is similar in shape to the spectrum of atmospheric neutrons but much more intense. The higher intensity results in accelerated life tests that are representative of the actual neutron radiation that a FCC may receive over a period of years.

  15. Achieving integrated convoys: cargo unmanned ground vehicle development and experimentation

    NASA Astrophysics Data System (ADS)

    Zych, Noah; Silver, David; Stager, David; Green, Colin; Pilarski, Thomas; Fischer, Jacob

    2013-05-01

    The Cargo UGV project was initiated in 2010 with the aim of developing and experimenting with advanced autonomous vehicles capable of being integrated unobtrusively into manned logistics convoys. The intent was to validate two hypotheses in complex, operationally representative environments: first, that unmanned tactical wheeled vehicles provide a force protection advantage by creating standoff distance to warfighters during ambushes or improvised explosive device attacks; and second, that these UGVs serve as force multipliers by enabling a single operator to control multiple unmanned assets. To assess whether current state-of-the-art autonomous vehicle technology was sufficiently capable to permit resupply missions to be executed with decreased risk and reduced manpower, and to assess the effect of UGVs on customary convoy tactics, the Marine Corps Warfighting Laboratory and the Joint Ground Robotics Enterprise sponsored Oshkosh Defense and the National Robotics Engineering Center to equip two standard Marine Corps cargo trucks for autonomous operation. This paper details the system architecture, hardware implementation, and software modules developed to meet the vehicle control, perception, and planner requirements compelled by this application. Additionally, the design of a custom human machine interface and an accompanying training program are described, as is the creation of a realistic convoy simulation environment for rapid system development. Finally, results are conveyed from a warfighter experiment in which the effectiveness of the training program for novice operators was assessed, and the impact of the UGVs on convoy operations was observed in a variety of scenarios via direct comparison to a fully manned convoy.

  16. A novel concentration and viability detection method for Brettanomyces using the Cellometer image cytometry.

    PubMed

    Martyniak, Brian; Bolton, Jason; Kuksin, Dmitry; Shahin, Suzanne M; Chan, Leo Li-Ying

    2017-01-01

    Brettanomyces spp. can present unique cell morphologies comprised of excessive pseudohyphae and budding, leading to difficulties in enumerating cells. The current cell counting methods include manual counting of methylene blue-stained yeasts or measuring optical densities using a spectrophotometer. However, manual counting can be time-consuming and has high operator-dependent variations due to subjectivity. Optical density measurement can also introduce uncertainties where instead of individual cells counted, an average of a cell population is measured. In contrast, by utilizing the fluorescence capability of an image cytometer to detect acridine orange and propidium iodide viability dyes, individual cell nuclei can be counted directly in the pseudohyphae chains, which can improve the accuracy and efficiency of cell counting, as well as eliminating the subjectivity from manual counting. In this work, two experiments were performed to demonstrate the capability of Cellometer image cytometer to monitor Brettanomyces concentrations, viabilities, and budding/pseudohyphae percentages. First, a yeast propagation experiment was conducted to optimize software counting parameters for monitoring the growth of Brettanomyces clausenii, Brettanomyces bruxellensis, and Brettanomyces lambicus, which showed increasing cell concentrations, and varying pseudohyphae percentages. The pseudohyphae formed during propagation were counted either as multiple nuclei or a single multi-nuclei organism, where the results of counting the yeast as a single multi-nuclei organism were directly compared to manual counting. Second, a yeast fermentation experiment was conducted to demonstrate that the proposed image cytometric analysis method can monitor the growth pattern of B. lambicus and B. clausenii during beer fermentation. The results from both experiments displayed different growth patterns, viability, and budding/pseudohyphae percentages for each Brettanomyces species. The proposed Cellometer image cytometry method can improve efficiency and eliminate operator-dependent variations of cell counting compared with the traditional methods, which can potentially improve the quality of beverage products employing Brettanomyces yeasts.

  17. SAE for the prediction of road traffic status from taxicab operating data and bus smart card data

    NASA Astrophysics Data System (ADS)

    Zhengfeng, Huang; Pengjun, Zheng; Wenjun, Xu; Gang, Ren

    Road traffic status is significant for trip decision and traffic management, and thus should be predicted accurately. A contribution is that we consider multi-modal data for traffic status prediction than only using single source data. With the substantial data from Ningbo Passenger Transport Management Sector (NPTMS), we wished to determine whether it was possible to develop Stacked Autoencoders (SAEs) for accurately predicting road traffic status from taxicab operating data and bus smart card data. We show that SAE performed better than linear regression model and Back Propagation (BP) neural network for determining the relationship between road traffic status and those factors. In a 26-month data experiment using SAE, we show that it is possible to develop highly accurate predictions (91% test accuracy) of road traffic status from daily taxicab operating data and bus smart card data.

  18. Project Echo: 960-Megacycle, 10-Kilowatt Transmitter

    NASA Technical Reports Server (NTRS)

    Schafer, J. P.; Brandt, R. H.

    1961-01-01

    A 10-kw transmitter operating at 960 to 961 Mc was used at the eastern terminus of the Project Echo communications experiment. This transmitter is located on Crawford's Hill near Holmdel, New Jersey. The 10-kw output feeds into a waveguide line leading to a 60-foot dish antenna. Exciter-driver units are available to drive the power amplifier with various modulations, such as wide-deviation FM, low-index phase modulation, single-sideband or double-sideband modulation with or without carrier, 960.05 or 961.05 Mc constant-frequency CW, and radar on-off pulses at 961.05 Mc. The main output amplifier consists primarily of a four-stage, externally-tuned-cavity, water-cooled klystron, operating at a beam voltage of 16 to 18 kv. The transmitter has been operated during many Moonbounce, tropospheric scatter, and Echo I tests with very satisfactory results. This paper describes its use before March 1, 1961.

  19. Fireworks Algorithm with Enhanced Fireworks Interaction.

    PubMed

    Zhang, Bei; Zheng, Yu-Jun; Zhang, Min-Xia; Chen, Sheng-Yong

    2017-01-01

    As a relatively new metaheuristic in swarm intelligence, fireworks algorithm (FWA) has exhibited promising performance on a wide range of optimization problems. This paper aims to improve FWA by enhancing fireworks interaction in three aspects: 1) Developing a new Gaussian mutation operator to make sparks learn from more exemplars; 2) Integrating the regular explosion operator of FWA with the migration operator of biogeography-based optimization (BBO) to increase information sharing; 3) Adopting a new population selection strategy that enables high-quality solutions to have high probabilities of entering the next generation without incurring high computational cost. The combination of the three strategies can significantly enhance fireworks interaction and thus improve solution diversity and suppress premature convergence. Numerical experiments on the CEC 2015 single-objective optimization test problems show the effectiveness of the proposed algorithm. The application to a high-speed train scheduling problem also demonstrates its feasibility in real-world optimization problems.

  20. Hybrid Circuits with Nanofluidic Diodes and Load Capacitors

    NASA Astrophysics Data System (ADS)

    Ramirez, P.; Garcia-Morales, V.; Gomez, V.; Ali, M.; Nasir, S.; Ensinger, W.; Mafe, S.

    2017-06-01

    The chemical and physical input signals characteristic of micro- and nanofluidic devices operating in ionic solutions should eventually be translated into output electric currents and potentials that are monitored with solid-state components. This crucial step requires the design of hybrid circuits showing robust electrical coupling between ionic solutions and electronic elements. We study experimentally and theoretically the connectivity of the nanofluidic diodes in single-pore and multipore membranes with conventional capacitor systems for the cases of constant, periodic, and white-noise input potentials. The experiments demonstrate the reliable operation of these hybrid circuits over a wide range of membrane resistances, electrical capacitances, and solution p H values. The model simulations are based on empirical equations that have a solid physical basis and provide a convenient description of the electrical circuit operation. The results should contribute to advance signal transduction and processing using nanopore-based biosensors and bioelectronic interfaces.

  1. Solar energy system performance evaluation: Seasonal report for Elcam Tempe Arizona State University, Tempe, Arizona

    NASA Technical Reports Server (NTRS)

    1980-01-01

    The solar system, Elcam-Tempe, was designed by Elcam Incorporated, Santa Barbara, California, to supply commercial domestic hot water heating systems to the Agriculture Department residence at Arizona State University. The building is a single story residence located at the agriculture experiment farm of the Arizona State University. The energy system's four modes of operation are described. Electrical energy savings at the site was a net of 5.54 million Btu after the 0.17 million Btu of operating energy required to operate collector loop circulating pump were subtracted. The energy savings due to solar was less than the system's potential. On an average, twice as much hot water could have been used with significant solar energy contribution. The system corrosion and deposits caused by using dissimilar metals in the collector loop was the only problem noted with the Elcam-Tempe system.

  2. Call sign intelligibility improvement using a spatial auditory display

    NASA Technical Reports Server (NTRS)

    Begault, Durand R.

    1994-01-01

    A spatial auditory display was designed for separating the multiple communication channels usually heard over one ear to different virtual auditory positions. The single 19 foot rack mount device utilizes digital filtering algorithms to separate up to four communication channels. The filters use four different binaural transfer functions, synthesized from actual outer ear measurements, to impose localization cues on the incoming sound. Hardware design features include 'fail-safe' operation in the case of power loss, and microphone/headset interfaces to the mobile launch communication system in use at KSC. An experiment designed to verify the intelligibility advantage of the display used 130 different call signs taken from the communications protocol used at NASA KSC. A 6 to 7 dB intelligibility advantage was found when multiple channels were spatially displayed, compared to monaural listening. The findings suggest that the use of a spatial auditory display could enhance both occupational and operational safety and efficiency of NASA operations.

  3. Reproducibility of toxicity test data as a function of mouse strain, animal lot, and operator. [for bisphenol A polycarbonate

    NASA Technical Reports Server (NTRS)

    Hilado, C. J.; Furst, A.

    1978-01-01

    The toxicity screening test method developed at the University of San Francisco was evaluated for reproducibility. The variables addressed were strain of mouse, lot of animals, and operator. There was a significant difference in response between Swiss Webster mice and ICR mice, with the latter exhibiting greater resistance. These two strains of mice are not interchangeable in this procedure. Variation between individual animals was significant and unavoidable. In view of this variation, between-lot and between-operator variations appear to have no practical significance. The significant variation between individual animals stresses the need for average values based on at least four animals, and preferably values based on at least two experiments and eight animals. Efforts to compare materials should be based on the evaluation of relatively simple responses using substantial numbers of animals, rather than on elaborate evaluation of single animals

  4. Reducing spontaneous recovery and reinstatement of operant performance through extinction-cues.

    PubMed

    Bernal-Gamboa, Rodolfo; Gámez, A Matías; Nieto, Javier

    2017-02-01

    It has been argued that the response recovery effects share a common mechanism. A possible way to test it is evaluating whether the techniques that impaired renewal would impair the other recovery effects as well. Two experiments with rats used a free operant procedure to explore whether an extinction-cue could prevent the spontaneous recovery and reinstatement of an extinguished lever-pressing. Both experiments consisted of four phases: Acquisition, Extinction and Test 1 and Test 2. First, all rats were trained to perform one instrumental response (R1) for food in context A, and a different instrumental response (R2) for food in context B. Then, responses were extinguished within the same context: R1 in context A and R2 in context B. Throughout this phase all rats received brief presentations of a tone (extinction-cue). In both experiments animals were tested twice. The first test was conducted immediately after the last extinction session. In this test, rats received the extinction-cue for both responses. During the second test, rats experienced the tone only for R1. In Experiment 1 rats were tested after 5days, while for Experiment 2 test 2 took place after a single session of re-exposure to the food. Both experiments showed a recovery effect (spontaneous recovery in Experiment 1 and reinstatement in Experiment 2) for both responses. However, a cue featured in extinction attenuated recovery of R1 in both experiments when presented on the test. The findings suggest that spontaneous recovery, reinstatement and renewal might share a common mechanism. In addition, the present data shows that using an extinction-cue could help to reduces relapsing of voluntary behaviors. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Single-incision retroperitoneoscopic adrenalectomy: a North American experience.

    PubMed

    Sho, Shonan; Yeh, Michael W; Li, Ning; Livhits, Masha J

    2017-07-01

    Endoscopic adrenalectomy is currently performed using multiple ports placed either transabdominally or retroperitoneally. We report our initial experience with single-incision retroperitoneoscopic adrenalectomy (SIRA). A prospective database of patients undergoing adrenalectomy from December 2013 through March 2016 was analyzed. We adopted conventional retroperitoneoscopic adrenalectomy (CORA) in December 2013 and transitioned to SIRA in March 2015. SIRA was performed using three trocars placed through a single 2-cm incision below the 12th rib. Clinical characteristics and outcomes were compared between patients undergoing SIRA and CORA. One hundred and five adrenalectomies were performed in 102 patients: 34 laparoscopic transperitoneal, 24 CORA, 37 SIRA and 7 open. The SIRA and CORA groups were similar with respect to clinical characteristics (SIRA vs. CORA: mean BMI 27.0 vs. 28.8 kg/m 2 , maximum BMI 38.9 vs. 44.3 kg/m 2 ; mean nodule size 3.2 vs. 3.2 cm, maximum nodule size 8.0 vs. 6.0 cm). One patient undergoing SIRA required placement of an additional 5-mm port because of extensive adhesions. No patients who underwent SIRA or CORA required conversion to open adrenalectomy. There were no deaths, and blood loss remained <10 mL for all cases. Operative length was similar between SIRA and CORA (105 vs. 92 min, P = 0.26). In multivariable linear regression analysis, nodule size > 5 cm (effect = 1.75, P < 0.001) and pheochromocytoma (effect = 1.30, P = 0.05) were significant predictors of increased operative length for SIRA. BMI and laterality (right vs. left) did not affect operative length. Rates of postoperative temporary abdominal wall relaxation, length of stay and postoperative pain medication use were similar between the two groups. SIRA is safe and feasible to implement as a refinement of CORA and may be applied to technically challenging cases involving obese patients or large nodules. The use of three ports allows for two-handed dissection, which may shorten the learning curve for many surgeons.

  6. Mission Control Operations: Employing a New High Performance Design for Communications Links Supporting Exploration Programs

    NASA Technical Reports Server (NTRS)

    Jackson, Dan E., Jr.

    2015-01-01

    The planetary exploration programs demand a totally new examination of data multiplexing, digital communications protocols and data transmission principles for both ground and spacecraft operations. Highly adaptive communications devices on-board and on the ground must provide the greatest possible transmitted data density between deployed crew personnel, spacecraft and ground control teams. Regarding these requirements, this proposal borrows from research into quantum mechanical computing by applying the concept of a qubit, a single bit that represents 16 states, to radio frequency (RF) communications link design for exploration programs. This concept of placing multiple character values into a single data bit can easily make the evolutionary steps needed to meet exploration mission demands. To move the qubit from the quantum mechanical research laboratory into long distance RF data transmission, this proposal utilizes polarization modulation of the RF carrier signal to represent numbers from zero to fifteen. It introduces the concept of a binary-to-hexadecimal converter that quickly chops any data stream into 16-bit words and connects variously polarized feedhorns to a single-frequency radio transmitter. Further, the concept relies on development of a receiver that uses low-noise amplifiers and an antenna array to quickly assess carrier polarity and perform hexadecimal to binary conversion. Early testbed experiments using the International Space Station (ISS) as an operations laboratory can be implemented to provide the most cost-effective return for research investment. The improvement in signal-to-noise ratio while supporting greater baseband data rates that could be achieved through this concept justifies its consideration for long-distance exploration programs.

  7. Sensing a buried resonant object by single-channel time reversal.

    PubMed

    Waters, Zachary J; Dzikowicz, Benjamin R; Holt, R Glynn; Roy, Ronald A

    2009-07-01

    Scaled laboratory experiments are conducted to assess the efficacy of iterative, single-channel time reversal for enhancement of monostatic returns from resonant spheres in the free field and buried in a sediment phantom. Experiments are performed in a water tank using a broad-band piston transducer operating between 0.4 and 1.5 MHz and calibrated using free surface reflections. Solid and hollow metallic spheres, 6.35 mm in diameter, are buried in a consolidation of 128-microm-mean- diameter spherical glass beads. The procedure consists of exciting the target object with a broadband pulse, sampling the return using a finite time window, reversing the signal in time, and using this reversed signal as the source waveform for the next interrogation. Results indicate that the spectrum of the returns rapidly converges to the dominant mode in the backscattering response of the target. Signal-to-noise enhancement of the target echo is demonstrated for a target at several burial depths. Images generated by scanning the transducer over the location of multiple buried targets demonstrate the ability of the technique to distinguish between targets of differing type and to yield an enhancement of different modes within the response of a single target as a function of transducer position and processing bandwidth.

  8. Robot-Assisted Laparoendoscopic Single-Site Partial Nephrectomy With the Novel Da Vinci Single-Site Platform: Initial Experience

    PubMed Central

    Komninos, Christos; Tuliao, Patrick; Kim, Dae Keun; Choi, Young Deuk; Chung, Byung Ha

    2014-01-01

    Purpose To report our initial clinical cases of robotic laparoendoscopic single-site (R-LESS) partial nephrectomy (PN) performed with the use of the novel Da Vinci R-LESS platform. Materials and Methods Three patients underwent R-LESS PN from November 2013 through February 2014. Perioperative and postoperative outcomes were collected and intraoperative difficulties were noted. Results Operative time and estimated blood loss volume ranged between 100 and 110 minutes and between 50 and 500 mL, respectively. None of the patients was transfused. All cases were completed with the off-clamp technique, whereas one case required conversion to the conventional (multiport) approach because of difficulty in creating the appropriate scope for safe tumor resection. No major postoperative complications occurred, and all tumors were resected in safe margins. Length of hospital stay ranged between 3 and 7 days. The lack of EndoWrist movements, the external collisions, and the bed assistant's limited working space were noticed to be the main drawbacks of this surgical method. Conclusions Our initial experience with R-LESS PN with the novel Da Vinci platform shows that even though the procedure is feasible, it should be applied in only appropriately selected patients. However, further improvement is needed to overcome the existing limitations. PMID:24955221

  9. The iso-response method: measuring neuronal stimulus integration with closed-loop experiments

    PubMed Central

    Gollisch, Tim; Herz, Andreas V. M.

    2012-01-01

    Throughout the nervous system, neurons integrate high-dimensional input streams and transform them into an output of their own. This integration of incoming signals involves filtering processes and complex non-linear operations. The shapes of these filters and non-linearities determine the computational features of single neurons and their functional roles within larger networks. A detailed characterization of signal integration is thus a central ingredient to understanding information processing in neural circuits. Conventional methods for measuring single-neuron response properties, such as reverse correlation, however, are often limited by the implicit assumption that stimulus integration occurs in a linear fashion. Here, we review a conceptual and experimental alternative that is based on exploring the space of those sensory stimuli that result in the same neural output. As demonstrated by recent results in the auditory and visual system, such iso-response stimuli can be used to identify the non-linearities relevant for stimulus integration, disentangle consecutive neural processing steps, and determine their characteristics with unprecedented precision. Automated closed-loop experiments are crucial for this advance, allowing rapid search strategies for identifying iso-response stimuli during experiments. Prime targets for the method are feed-forward neural signaling chains in sensory systems, but the method has also been successfully applied to feedback systems. Depending on the specific question, “iso-response” may refer to a predefined firing rate, single-spike probability, first-spike latency, or other output measures. Examples from different studies show that substantial progress in understanding neural dynamics and coding can be achieved once rapid online data analysis and stimulus generation, adaptive sampling, and computational modeling are tightly integrated into experiments. PMID:23267315

  10. Ultrafast optical control of individual quantum dot spin qubits.

    PubMed

    De Greve, Kristiaan; Press, David; McMahon, Peter L; Yamamoto, Yoshihisa

    2013-09-01

    Single spins in semiconductor quantum dots form a promising platform for solid-state quantum information processing. The spin-up and spin-down states of a single electron or hole, trapped inside a quantum dot, can represent a single qubit with a reasonably long decoherence time. The spin qubit can be optically coupled to excited (charged exciton) states that are also trapped in the quantum dot, which provides a mechanism to quickly initialize, manipulate and measure the spin state with optical pulses, and to interface between a stationary matter qubit and a 'flying' photonic qubit for quantum communication and distributed quantum information processing. The interaction of the spin qubit with light may be enhanced by placing the quantum dot inside a monolithic microcavity. An entire system, consisting of a two-dimensional array of quantum dots and a planar microcavity, may plausibly be constructed by modern semiconductor nano-fabrication technology and could offer a path toward chip-sized scalable quantum repeaters and quantum computers. This article reviews the recent experimental developments in optical control of single quantum dot spins for quantum information processing. We highlight demonstrations of a complete set of all-optical single-qubit operations on a single quantum dot spin: initialization, an arbitrary SU(2) gate, and measurement. We review the decoherence and dephasing mechanisms due to hyperfine interaction with the nuclear-spin bath, and show how the single-qubit operations can be combined to perform spin echo sequences that extend the qubit decoherence from a few nanoseconds to several microseconds, more than 5 orders of magnitude longer than the single-qubit gate time. Two-qubit coupling is discussed, both within a single chip by means of exchange coupling of nearby spins and optically induced geometric phases, as well as over longer-distances. Long-distance spin-spin entanglement can be generated if each spin can emit a photon that is entangled with the spin, and these photons are then interfered. We review recent work demonstrating entanglement between a stationary spin qubit and a flying photonic qubit. These experiments utilize the polarization- and frequency-dependent spontaneous emission from the lowest charged exciton state to single spin Zeeman sublevels.

  11. Single-incision laparoscopic appendectomy performed above the pubic symphysis - a new scarless approach.

    PubMed

    Yu, J; Wang, Y N; Hu, Y F; Cheng, X; Zhen, L; Li, G X

    2011-01-01

    The three-port method is commonly used for laparoscopic appendectomy. To obtain a better cosmetic result, we have selected the single-incision laparoscopic appendectomy to be performed above the pubic symphysis. We performed six single-incision laparoscopic appendectomies above the pubic symphysis. During each operation, a 2 cm transverse incision was made in the pubic hair area 3-4 cm above the pubic symphysis. A 5 mm trocar was then placed as an observation port with another two 5 mm trocars as main- and side-operating ports. The laparoscopic appendectomy was performed using this single-incision method. Six patients (five male and one female; body mass indexes of 18.07, 19.27, 21.67, 18.34, 26.83 and 22.46 kg/m(2), respectively) underwent successful single-incision laparoscopic appendectomy above the pubic symphysis. Operating times were recorded at 55, 58, 47, 51, 42 and 33 minutes, the corresponding post-operative anal ventilation times were 25, 24, 22, 18, 7 and 10 hours, while post-operative hospitalization periods stand at 3, 5, 2, 1, 3 and 2 days, respectively. No complications occurred during or post-operation. Our initial work shows that a single-incision laparoscopic appendectomy performed above the pubic symphysis is feasible and safe and yields excellent post-operative cosmetic results.

  12. A multiple-cathode, high-power, rectangular ion thruster discharge chamber of increasing thruster lifetime

    NASA Astrophysics Data System (ADS)

    Rovey, Joshua Lucas

    Ion thrusters are high-efficiency, high-specific impulse space propulsion systems proposed for deep space missions requiring thruster operational lifetimes of 7--14 years. One of the primary ion thruster components is the discharge cathode assembly (DCA). The DCA initiates and sustains ion thruster operation. Contemporary ion thrusters utilize one molybdenum keeper DCA that lasts only ˜30,000 hours (˜3 years), so single-DCA ion thrusters are incapable of satisfying the mission requirements. The aim of this work is to develop an ion thruster that sequentially operates multiple DCAs to increase thruster lifetime. If a single-DCA ion thruster can operate 3 years, then perhaps a triple-DCA thruster can operate 9 years. Initially, a multiple-cathode discharge chamber (MCDC) is designed and fabricated. Performance curves and grid-plane current uniformity indicate operation similar to other thrusters. Specifically, the configuration that balances both performance and uniformity provides a production cost of 194 W/A at 89% propellant efficiency with a flatness parameter of 0.55. One of the primary MCDC concerns is the effect an operating DCA has on the two dormant cathodes. Multiple experiments are conducted to determine plasma properties throughout the MCDC and near the dormant cathodes, including using "dummy" cathodes outfitted with plasma diagnostics and internal plasma property mapping. Results are utilized in an erosion analysis that suggests dormant cathodes suffer a maximum pre-operation erosion rate of 5--15 mum/khr (active DCA maximum erosion is 70 mum/khr). Lifetime predictions indicate that triple-DCA MCDC lifetime is approximately 2.5 times longer than a single-DCA thruster. Also, utilization of new keeper materials, such as carbon graphite, may significantly decrease both active and dormant cathode erosion, leading to a further increase in thruster lifetime. Finally, a theory based on the near-DCA plasma potential structure and propellant flow rate effects is developed to explain active DCA erosion. The near-DCA electric field pulls ions into the DCA such that they bombard and erode the keeper. Charge-exchange collisions between bombarding ions and DCA-expelled neutral atoms reduce erosion. The theory explains ion thruster long-duration wear-test results and suggests increasing propellant flow rate may eliminate or reduce DCA erosion.

  13. V-FASTR: THE VLBA FAST RADIO TRANSIENTS EXPERIMENT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wayth, Randall B.; Tingay, Steven J.; Brisken, Walter F.

    2011-07-10

    Recent discoveries of dispersed, non-periodic impulsive radio signals with single-dish radio telescopes have sparked significant interest in exploring the relatively uncharted space of fast transient radio signals. Here we describe V-FASTR, an experiment to perform a blind search for fast transient radio signals using the Very Long Baseline Array (VLBA). The experiment runs entirely in a commensal mode, alongside normal VLBA observations and operations. It is made possible by the features and flexibility of the DiFX software correlator that is used to process VLBA data. Using the VLBA for this type of experiment offers significant advantages over single-dish experiments, includingmore » a larger field of view, the ability to easily distinguish local radio-frequency interference from real signals, and the possibility to localize detected events on the sky to milliarcsecond accuracy. We describe our software pipeline, which accepts short integration ({approx} ms) spectrometer data from each antenna in real time during correlation and performs an incoherent dedispersion separately for each antenna, over a range of trial dispersion measures. The dedispersed data are processed by a sophisticated detector and candidate events are recorded. At the end of the correlation, small snippets of the raw data at the time of the events are stored for further analysis. We present the results of our event detection pipeline from some test observations of the pulsars B0329+54 and B0531+21 (the Crab pulsar).« less

  14. Long-term Outcomes after Truncus Arteriosus Repair: A Single-center Experience for More than 40 Years.

    PubMed

    Asagai, Seiji; Inai, Kei; Shinohara, Tokuko; Tomimatsu, Hirofumi; Ishii, Tetsuko; Sugiyama, Hisashi; Park, In-Sam; Nagashima, Mitsugi; Nakanishi, Toshio

    2016-12-01

    This study aimed to analyze long-term survival and functional outcomes after truncus arteriosus repair in a single institution with more than 40 years of follow-up. Medical records were analyzed retrospectively in 52 patients who underwent the Rastelli procedure for truncus arteriosus repair between 1974 and 2002. Thirty-five patients survived the initial repair. The median age at the initial operation was 2.8 months (range, 0.1-123 months) and the body weight was 3.9 kg (range, 1.6 to 15.0 kg). The median age at follow-up was 23.6 years (range, 12.4 to 44.5 years). The median follow-up duration was 23.4 years (range, 12.3 to 40.7 years). The actuarial survival rate was 97% at 10 years and 93% at both 20 years and 40 years after the initial operation. At follow-up, most patients were in New York Heart Association (NYHA) functional classes I (73%) and II (24%). Thirty-six percent of patients had full-time jobs, 40% were students, and 21% were unemployed. Most patients (97%) had undergone conduit reoperations. Freedom from reoperation for right ventricular (RV) outflow and pulmonary artery (PA) stenosis was 59% at 5 years, 28% at 10 years, and 3% at 20 years after the initial operation. Freedom from catheter interventions for RV outflow and PA stenosis was 59% at 5 years, 47% at 10 years, and 38% at 20 years after the initial operation. Freedom from truncal valve replacement was 88% at 5 years, 85% at 10 years, and 70% at 20 years after the initial operation. In this single-center retrospective study, with long-term follow-up after repair of truncus arteriosus, long-term survival and functional outcomes were acceptable, despite the requirement for reoperation and multiple catheter interventions for RV outflow and PA stenosis in almost all patients, and the frequent requirement for late truncal valve operations. © 2016 The Authors. Congenital Heart Disease published by Wiley Periodicals, Inc.

  15. Brewery and liquid manure wastewaters as potential feedstocks for microbial fuel cells: a performance study.

    PubMed

    Angosto, J M; Fernández-López, J A; Godínez, C

    2015-01-01

    This work aims at the comparison of the electrical and chemical performance of microbial fuel cells (MFCs) fed with several types of brewery and manure industrial wastewaters. Experiments were conducted in a single-cell MFC with the cathode exposed to air operated in batch and fed-batch modes. In fed-batch mode, after 4 days of operation, a standard MFC was refilled with crude wastewater to regenerate the biofilm and recreate initial feeding conditions. Brewery wastewater (CV1) mixed with pig-farm liquid manure (PU sample) gave the highest voltage (199.8 mV) and power density (340 mW/m3) outputs than non-mixed brewery waste water. Also, coulombic efficiency is much larger in the mixture (11%) than in the others (2-3%). However, in terms of chemical oxygen demand removal, the performance showed to be poorer (53%) for the mixed sample than in the pure brewery sample (93%). Fed-batch operation showed to be a good alternate for quasi-continuous operation, with equivalent electrical and chemical yields as compared with normal batchwise operation.

  16. 14 CFR 121.434 - Operating experience, operating cycles, and consolidation of knowledge and skills.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Operating experience, operating cycles, and... Qualifications § 121.434 Operating experience, operating cycles, and consolidation of knowledge and skills. (a... position, the operating experience, operating cycles, and the line operating flight time for consolidation...

  17. Mind Operational Semantics and Brain Operational Architectonics: A Putative Correspondence

    PubMed Central

    Benedetti, Giulio; Marchetti, Giorgio; Fingelkurts, Alexander A; Fingelkurts, Andrew A

    2010-01-01

    Despite allowing for the unprecedented visualization of brain functional activity, modern neurobiological techniques have not yet been able to provide satisfactory answers to important questions about the relationship between brain and mind. The aim of this paper is to show how two different but complementary approaches, Mind Operational Semantics (OS) and Brain Operational Architectonics (OA), can help bridge the gap between a specific kind of mental activity—the higher-order reflective thought or linguistic thought—and brain. The fundamental notion that allows the two different approaches to be jointly used under a common framework is that of operation. According to OS, which is based on introspection and linguistic data, the meanings of words can be analyzed in terms of elemental mental operations (EOMC), amongst which those of attention play a key role. Linguistic thought is made possible by special kinds of elements, which OS calls “correlators”, which have the function of tying together the other elements of thought, which OS calls “correlata” (a "correlational network” that is, a sentence, is so formed). Therefore, OS conceives of linguistic thought as a hierarchy of operations of increasing complexity. Likewise, according to OA, which is based on the joint analysis of cognitive and electromagnetic data (EEG and MEG), every conscious phenomenon is brought to existence by the joint operations of many functional and transient neuronal assemblies in the brain. According to OA, the functioning of the brain is always operational (made up of operations), and its structure is characterized by a hierarchy of operations of increasing complexity: single neurons, single assemblies of neurons, synchronized neuronal assemblies or Operational Modules (OM), integrated or complex OMs. The authors put forward the hypothesis that the whole level of OS’s description (EOMC, correlators, and correlational networks) corresponds to the level of OMs (or set of them) of different complexity within OA’s theory: EOMC could correspond to simple OMs, correlators to complex OMs and the correlational network to a set of simple and complex OMs. Finally, a set of experiments is proposed to verify the putative correspondence between OS and OA and prove the existence of an integrated continuum between brain and mind. PMID:21113277

  18. Gas Electron Multipler (GEM) detectors for parity-violating electron scattering experiments at Jefferson Lab

    NASA Astrophysics Data System (ADS)

    Matter, John; Gnanvo, Kondo; Liyanage, Nilanga; Solid Collaboration; Moller Collaboration

    2017-09-01

    The JLab Parity Violation In Deep Inelastic Scattering (PVDIS) experiment will use the upgraded 12 GeV beam and proposed Solenoidal Large Intensity Device (SoLID) to measure the parity-violating electroweak asymmetry in DIS of polarized electrons with high precision in order to search for physics beyond the Standard Model. Unlike many prior Parity-Violating Electron Scattering (PVES) experiments, PVDIS is a single-particle tracking experiment. Furthermore the experiment's high luminosity combined with the SoLID spectrometer's open configuration creates high-background conditions. As such, the PVDIS experiment has the most demanding tracking detector needs of any PVES experiment to date, requiring precision detectors capable of operating at high-rate conditions in PVDIS's full production luminosity. Developments in large-area GEM detector R&D and SoLID simulations have demonstrated that GEMs provide a cost-effective solution for PVDIS's tracking needs. The integrating-detector-based JLab Measurement Of Lepton Lepton Electroweak Reaction (MOLLER) experiment requires high-precision tracking for acceptance calibration. Large-area GEMs will be used as tracking detectors for MOLLER as well. The conceptual designs of GEM detectors for the PVDIS and MOLLER experiments will be presented.

  19. Operative interventions for failed heller myotomy: a single institution experience.

    PubMed

    Pallati, Pradeep K; Mittal, Sumeet K

    2011-03-01

    Recurrent dysphagia and/or gastroesophageal reflux (GER) are failures of treatment after Heller myotomy for achalasia. We present our single center experience with surgical interventions for these failures. We did a retrospective analysis of a prospectively collected database. Based on preoperative symptoms and endoscopy, esophagogram, and manometry results, patients were divided into three groups to guide management. Telephone follow-up was done using a structured foregut questionnaire. Between December 2003 and June 2009, 16 patients underwent operative interventions for disabling symptoms after previous Heller myotomy. Eight patients presented primarily with recurrent dysphagia and underwent transabdominal Heller myotomy with partial fundoplication. Seven patients reported good to excellent symptom relief at mean follow-up of 42 months. One patient reported no relief and eventually required esophageal bypass with retrosternal gastric pull-up. Four patients presented with uncontrolled GER. Two patients who underwent redo partial fundoplication reported poor symptomatic outcome and one patient has since undergone short limb Roux-en-y gastric bypass (SLRNYGB) with excellent symptom relief. The other two patients underwent SLRNYGB with excellent relief at 10 months. Four patients had end stage achalasia and underwent esophageal resection with reconstruction. All reported excellent symptom relief at mean follow-up of 36 months. Transabdominal redo Heller myotomy for dysphagia has good outcomes. Redo fundoplication for GER after previous myotomy has poor results and SLRNYGB is an effective option in these patients. Esophageal resection remains an effective, albeit morbid, option for end-stage achalasia.

  20. Tactile feedback to the palm using arbitrarily shaped DEA

    NASA Astrophysics Data System (ADS)

    Mößinger, Holger; Haus, Henry; Kauer, Michaela; Schlaak, Helmut F.

    2014-03-01

    Tactile stimulation enhances user experience and efficiency in human machine interaction by providing information via another sensory channel to the human brain. DEA as tactile interfaces have been in the focus of research in recent years. Examples are (vibro-) tactile keyboards or Braille displays. These applications of DEA focus mainly on interfacing with the user's fingers or fingertips only - demonstrating the high spatial resolution achievable with DEA. Besides providing a high resolution, the flexibility of DEA also allows designing free form surfaces equipped with single actuators or actuator matrices which can be fitted to the surface of the human skin. The actuators can then be used to provide tactile stimuli to different areas of the body, not to the fingertips only. Utilizing and demonstrating this flexibility we designed a free form DEA pad shaped to fit into the inside of the human palm. This pad consists of four single actuators which can provide e.g. directional information such as left, right, up and down. To demonstrate the value of such free form actuators we manufactured a PC-mouse using 3d printing processes. The actuator pad is mounted on the back of the mouse, resting against the palm while operating it. Software on the PC allows control of the vibration patterns displayed by the actuators. This allows helping the user by raising attention to certain directions or by discriminating between different modes like "pick" or "manipulate". Results of first tests of the device show an improved user experience while operating the PC mouse.

  1. Stable CW Single Frequency Operation of Fabry-Perot Laser Diodes by Self-Injection Phase Locking

    NASA Technical Reports Server (NTRS)

    Duerksen, Gary L.; Krainak, Michael A.

    1999-01-01

    Previously, single-frequency semiconductor laser operation using fiber Bragg gratings has been achieved by tWo methods: 1) use of the FBG as the output coupler for an anti-reflection-coated semiconductor gain element'; 2) pulsed operation of a gain-switched Fabry-Perot laser diode with FBG-optical and RF-electrical feedback'. Here, we demonstrate CW single frequency operation from a non-AR coated Fabry-Perot laser diode using only FBG optical feedback.

  2. Stable CW Single-Frequency Operation of Fabry-Perot Laser Diodes by Self-Injection Phase Locking

    NASA Technical Reports Server (NTRS)

    Duerksen, Gary L.; Krainak, Michael A.

    1998-01-01

    Previously, single-frequency semiconductor laser operation using fiber Bragg gratings (FBG) has been achieved by two methods: (1) use of the FBG as the output coupler for an anti-reflection-coated semiconductor gain element; (2) pulsed operation of a gain-switched Fabry-Perot laser diode with FBG-optical and RF-electrical feedback. Here, we demonstrate CW single frequency operation from a non-AR coated Fabry-Perot laser diode using only FBG optical feedback.

  3. Consensus statement of the consortium for LESS cholecystectomy.

    PubMed

    Ross, Sharona; Rosemurgy, Alexander; Albrink, Michael; Choung, Edward; Dapri, Giovanni; Gallagher, Scott; Hernandez, Jonathan; Horgan, Santiago; Kelley, William; Kia, Michael; Marks, Jeffrey; Martinez, Jose; Mintz, Yoav; Oleynikov, Dmitry; Pryor, Aurora; Rattner, David; Rivas, Homero; Roberts, Kurt; Rubach, Eugene; Schwaitzberg, Steven; Swanstrom, Lee; Sweeney, John; Wilson, Erik; Zemon, Harry; Zundel, Natan

    2012-10-01

    Many surgeons attempting Laparo-Endoscopic Single Site (LESS) cholecystectomy have found the operation difficult, which is inconsistent with our experience. This article is an attempt to promote a standardized approach that we feel surgeons with laparoscopic skills can perform safely and efficiently. This is a four-trocar approach consistent with the four incisions utilized in conventional laparoscopic cholecystectomy. After administration of general anesthesia, marcaine is injected at the umbilicus and a 12-mm vertical incision is made through the already existing anatomical scar of the umbilicus. A single four-trocar port is inserted. A 5-mm deflectable-tip laparoscope is placed through the trocar at the 8 o'clock position, a bariatric length rigid grasper is inserted through the trocar at the 4 o'clock position (to grasp the fundus), and a rigid bent grasper is placed through the 10-mm port (to grasp the infundibulum). This arrangement of the instruments promotes minimal internal and external instrument clashing with simultaneous optimization of the operative view. This orientation allows retraction of the gallbladder in a cephalad and lateral direction, development of a window between the gallbladder and the liver which promotes the "critical view" of the cystic duct and artery, and provides triangulation with excellent visualization of the operative field. The operation is concluded with diaphragmatic irrigation of marcaine solution to minimize postoperative pain. Standardization of LESS cholecystectomy will speed adoption, reduce intraoperative complications, and improve the efficiency and safety of the approach.

  4. Peritonitis: 10 years' experience in a single surgical unit.

    PubMed

    Agarwal, Nitin; Saha, Sudipta; Srivastava, Anurag; Chumber, Sunil; Dhar, Anita; Garg, Sanket

    2007-01-01

    Peritonitis secondary to gut perforation is still one of the commonest surgical emergencies in India and is associated with high morbidity and mortality. The present study examines the aetiology and outcome of peritonitis cases operated on in our surgical unit, and compares our findings with those of previous studies performed between 1981 and 1991. A retrospective study of 260 peritonitis patients operated on in a single surgical unit from 1995 to 2006 was done and data involving clinical presentation, operative findings and post-operative course were studied and analysed. Causes of peritonitis were small bowel perforation (96 ileal, 17 jejunal), peptic perforation (45 duodenal, 16 gastric), appendicular perforation (36), primary peritonitis (8), and others (42). The incidence of major complications was 25% (burst-11%, leak-5%, intraabdominal abscess-5%, multi-organ failure-6.5%). The overall mortality was 10%. High mortality was observed in jejunal, gall bladder and liver abscess perforation cases (> 20%). Histopathological evaluation (143 specimens) revealed tuberculosis in 42 (mostly small bowel), malignancy in 8, and inflammation in the rest. Comparisons with a similar study carried out in the same unit and published in 1995 revealed similar demographic features and mortality, but a change in the most common cause (peptic ulcer perforation to small bowel perforation), and an increased performance of enterostomy compared with primary repair in small bowel perforation and a decrease in the leak rate (13% to 4%). Small bowel perforation is the commonest form of perforation and the mortality rate associated with peritonitis remains unchanged.

  5. Systems and Algorithms for Automated Collaborative Observation Using Networked Robotic Cameras

    ERIC Educational Resources Information Center

    Xu, Yiliang

    2011-01-01

    The development of telerobotic systems has evolved from Single Operator Single Robot (SOSR) systems to Multiple Operator Multiple Robot (MOMR) systems. The relationship between human operators and robots follows the master-slave control architecture and the requests for controlling robot actuation are completely generated by human operators. …

  6. Chiral photonic crystal fibers with single mode and single polarization

    NASA Astrophysics Data System (ADS)

    Li, She; Li, Junqing

    2015-12-01

    Chiral photonic crystal fiber (PCF) with a solid core is numerically investigated by a modified chiral plane-wave expansion method. The effects of structural parameters and chirality strength are analyzed on single-polarization single-mode range and polarization states of guided modes. The simulation demonstrates that the chiral photonic crystal fiber compared to its achiral counterpart possesses another single-circular-polarization operation range, which is located in the short-wavelength region. The original single-polarization operation range in the long-wavelength region extends to the short wavelength caused by introducing chirality. Then this range becomes a broadened one with elliptical polarization from linear polarization. With increase of chirality, the two single-polarization single-mode ranges may fuse together. By optimizing the structure, an ultra-wide single-circular-polarization operation range from 0.5 μm to 1.67 μm for chiral PCF can be realized with moderate chirality strength.

  7. Single chip camera active pixel sensor

    NASA Technical Reports Server (NTRS)

    Shaw, Timothy (Inventor); Pain, Bedabrata (Inventor); Olson, Brita (Inventor); Nixon, Robert H. (Inventor); Fossum, Eric R. (Inventor); Panicacci, Roger A. (Inventor); Mansoorian, Barmak (Inventor)

    2003-01-01

    A totally digital single chip camera includes communications to operate most of its structure in serial communication mode. The digital single chip camera include a D/A converter for converting an input digital word into an analog reference signal. The chip includes all of the necessary circuitry for operating the chip using a single pin.

  8. Experimental thermodynamics of single molecular motor

    PubMed Central

    Toyabe, Shoichi; Muneyuki, Eiro

    2013-01-01

    Molecular motor is a nano-sized chemical engine that converts chemical free energy to mechanical motions. Hence, the energetics is as important as kinetics in order to understand its operation principle. We review experiments to evaluate the thermodynamic properties of a rotational F1-ATPase motor (F1-motor) at a single-molecule level. We show that the F1-motor achieves 100% thermo dynamic efficiency at the stalled state. Furthermore, the motor reduces the internal irreversible heat inside the motor to almost zero and achieves a highly-efficient free energy transduction close to 100% during rotations far from quasistatic process. We discuss the mechanism of how the F1-motor achieves such a high efficiency, which highlights the remarkable property of the nano-sized engine F1-motor. PMID:27493546

  9. Sampling-based ensemble segmentation against inter-operator variability

    NASA Astrophysics Data System (ADS)

    Huo, Jing; Okada, Kazunori; Pope, Whitney; Brown, Matthew

    2011-03-01

    Inconsistency and a lack of reproducibility are commonly associated with semi-automated segmentation methods. In this study, we developed an ensemble approach to improve reproducibility and applied it to glioblastoma multiforme (GBM) brain tumor segmentation on T1-weigted contrast enhanced MR volumes. The proposed approach combines samplingbased simulations and ensemble segmentation into a single framework; it generates a set of segmentations by perturbing user initialization and user-specified internal parameters, then fuses the set of segmentations into a single consensus result. Three combination algorithms were applied: majority voting, averaging and expectation-maximization (EM). The reproducibility of the proposed framework was evaluated by a controlled experiment on 16 tumor cases from a multicenter drug trial. The ensemble framework had significantly better reproducibility than the individual base Otsu thresholding method (p<.001).

  10. Biasing, acquisition, and interpretation of a dense Langmuir probe array in NSTX.

    PubMed

    Jaworski, M A; Kallman, J; Kaita, R; Kugel, H; LeBlanc, B; Marsala, R; Ruzic, D N

    2010-10-01

    A dense array of 99 Langmuir probes has been installed in the lower divertor region of the National Spherical Torus Experiment (NSTX). This array is instrumented with a system of electronics that allows flexibility in the choice of probes to bias as well as the type of measurement (including standard swept, single probe, triple probe, and operation as passive floating potential and scrape-off-layer SOL current monitors). The use of flush-mounted probes requires careful interpretation. The time dependent nature of the SOL makes swept-probe traces difficult to interpret. To overcome these challenges, the single- and triple-Langmuir probe signals are used in complementary fashion to determine the temperature and density at the probe location. A comparison to midplane measurements is made.

  11. High Frequency, High Gradient Dielectric Wakefield Acceleration Experiments at SLAC and BNL

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rosenzweig, James; /UCLA; Travish, Gil

    Given the recent success of >GV/m dielectric wakefield accelerator (DWA) breakdown experiments at SLAC, and follow-on coherent Cerenkov radiation production at the UCLA Neptune, a UCLA-USC-SLAC collaboration is now implementing a new set of experiments that explore various DWA scenarios. These experiments are motivated by the opportunities presented by the approval of FACET facility at SLAC, as well as unique pulse-train wakefield drivers at BNL. The SLAC experiments permit further exploration of the multi-GeV/m envelope in DWAs, and will entail investigations of novel materials (e.g. CVD diamond) and geometries (Bragg cylindrical structures, slab-symmetric DWAs), and have an over-riding goal ofmore » demonstrating >GeV acceleration in {approx}33 cm DWA tubes. In the nearer term before FACET's commissioning, we are planning measurements at the BNL ATF, in which we drive {approx}50-200 MV/m fields with single pulses or pulse trains. These experiments are of high relevance to enhancing linear collider DWA designs, as they will demonstrate potential for efficient operation with pulse trains.« less

  12. All-Optical Fiber Hanbury Brown & Twiss Interferometer to study 1300 nm single photon emission of a metamorphic InAs Quantum Dot

    PubMed Central

    Muñoz-Matutano, G.; Barrera, D.; Fernández-Pousa, C.R.; Chulia-Jordan, R.; Seravalli, L.; Trevisi, G.; Frigeri, P.; Sales, S.; Martínez-Pastor, J.

    2016-01-01

    New optical fiber based spectroscopic tools open the possibility to develop more robust and efficient characterization experiments. Spectral filtering and light reflection have been used to produce compact and versatile fiber based optical cavities and sensors. Moreover, these technologies would be also suitable to study N-photon correlations, where high collection efficiency and frequency tunability is desirable. We demonstrated single photon emission of a single quantum dot emitting at 1300 nm, using a Fiber Bragg Grating for wavelength filtering and InGaAs Avalanche Photodiodes operated in Geiger mode for single photon detection. As we do not observe any significant fine structure splitting for the neutral exciton transition within our spectral resolution (46 μeV), metamorphic QD single photon emission studied with our all-fiber Hanbury Brown & Twiss interferometer could lead to a more efficient analysis of entangled photon sources at telecom wavelength. This all-optical fiber scheme opens the door to new first and second order interferometers to study photon indistinguishability, entangled photon and photon cross correlation in the more interesting telecom wavelengths. PMID:27257122

  13. The National Institutes of Health's Biomedical Translational Research Information System (BTRIS): Design, Contents, Functionality and Experience to Date

    PubMed Central

    Cimino, James J.; Ayres, Elaine J.; Remennik, Lyubov; Rath, Sachi; Freedman, Robert; Beri, Andrea; Chen, Yang; Huser, Vojtech

    2013-01-01

    The US National Institutes of Health (NIH) has developed the Biomedical Translational Research Information System (BTRIS) to support researchers’ access to translational and clinical data. BTRIS includes a data repository, a set of programs for loading data from NIH electronic health records and research data management systems, an ontology for coding the disparate data with a single terminology, and a set of user interface tools that provide access to identified data from individual research studies and data across all studies from which individually identifiable data have been removed. This paper reports on unique design elements of the system, progress to date and user experience after five years of development and operation. PMID:24262893

  14. Village microgrids: The Chile project

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baring-Gould, E.I.

    1997-12-01

    This paper describes a village application in Chile. The objective was to demonstrate the technical, economic and institutional viability of renewable energy for rural electrification, as well as to allow local partners to gain experience with hybrid/renewable technology, resource assessment, system siting and operation. A micro-grid system is viewed as a small village system, up to 1200 kWh/day load with a 50 kW peak load. It can consist of components of wind, photovoltaic, batteries, and conventional generators. It is usually associated with a single generator source, and uses batteries to cover light day time loads. This paper looks at themore » experiences learned from this project with regard to all of the facets of planning and installing this project.« less

  15. On the DEAP-3600 resurfacing

    NASA Astrophysics Data System (ADS)

    Giampa, P.

    2018-01-01

    The DEAP-3600 experiment is a single-phase detector that can hold up to 3600 kg of liquid argon to search for dark matter at SNOLAB in Sudbury Canada, 6800 ft. underground. The projected sensitivity to the spin-independent WIMP-nucleon cross-section is 10-46 cm2 for a WIMP mass of 100 GeV/c2. One of the primary background sources to the WIMP search are alpha decays occurring on the surface of the experiment, which only deposit a tiny fraction of their energy in the argon. The work reported here focuses on the development and operation of a custom designed robot, the Resurfacer, which was used to remove 500 micrometers from the inner-most layer of the detector's acrylic cryostat, thus removing contaminations introduced during construction.

  16. Tunka-Rex: energy reconstruction with a single antenna station

    NASA Astrophysics Data System (ADS)

    Hiller, R.; Bezyazeekov, P. A.; Budnev, N. M.; Fedorov, O.; Gress, O. A.; Haungs, A.; Huege, T.; Kazarina, Y.; Kleifges, M.; Korosteleva, E. E.; Kostunin, D.; Krömer, O.; Kungel, V.; Kuzmichev, L. A.; Lubsandorzhiev, N.; Mirgazov, R. R.; Monkhoev, R.; Osipova, E. A.; Pakhorukov, A.; Pankov, L.; Prosin, V. V.; Rubtsov, G. I.; Schröder, F. G.; Wischnewski, R.; Zagorodnikov, A.

    2017-03-01

    The Tunka-Radio extension (Tunka-Rex) is a radio detector for air showers in Siberia. From 2012 to 2014, Tunka-Rex operated exclusively together with its host experiment, the air-Cherenkov array Tunka-133, which provided trigger, data acquisition, and an independent air-shower reconstruction. It was shown that the air-shower energy can be reconstructed by Tunka-Rex with a precision of 15% for events with signal in at least 3 antennas, using the radio amplitude at a distance of 120 m from the shower axis as an energy estimator. Using the reconstruction from the host experiment Tunka-133 for the air-shower geometry (shower core and direction), the energy estimator can in principle already be obtained with measurements from a single antenna, close to the reference distance. We present a method for event selection and energy reconstruction, requiring only one antenna, and achieving a precision of about 20%. This method increases the effective detector area and lowers thresholds for zenith angle and energy, resulting in three times more events than in the standard reconstruction.

  17. An Approach Toward Replacing Vanadium: A Single Organic Molecule for the Anode and Cathode of an Aqueous Redox-Flow Battery.

    PubMed

    Janoschka, Tobias; Friebe, Christian; Hager, Martin D; Martin, Norbert; Schubert, Ulrich S

    2017-04-01

    By combining a viologen unit and a 2,2,6,6-tetramethylpiperidin-1-oxyl (TEMPO) radical in one single combi-molecule, an artificial bipolar redox-active material, 1-(4-(((1-oxyl-2,2,6,6-tetramethylpiperidin-4-yl)oxy)carbonyl)benzyl)-1'-methyl-[4,4'-bipyridine]-1,1'-diium-chloride ( VIOTEMP ), was created that can serve as both the anode (-0.49 V) and cathode (0.67 V vs. Ag/AgCl) in a water-based redox-flow battery. While it mimics the redox states of flow battery metals like vanadium, the novel aqueous electrolyte does not require strongly acidic media and is best operated at pH 4. The electrochemical properties of VIOTEMP were investigated by using cyclic voltammetry, rotating disc electrode experiments, and spectroelectrochemical methods. A redox-flow battery was built and the suitability of the material for both electrodes was demonstrated through a polarity-inversion experiment. Thus, an organic aqueous electrolyte system being safe in case of cross contamination is presented.

  18. Transaxillary Robotic Thyroid Surgery: A Preliminary European Experience

    PubMed Central

    Lallemant, Benjamin; Chambon, Guillaume; Galy-Bernadoy, Camille; Chapuis, Héliette; Guedj, Anne-Marie; Pham, Huy Trang; Lallemant, Jean-Gabriel; Rupp, Damien

    2013-01-01

    Background Robot-assisted endoscopic transaxillary thyroidectomy is an emerging surgical technique that needs to be evaluated in European patients. We evaluate the feasibility and preliminary results of our experience of this technique in a cohort of patients from within a single European university hospital (Nîmes, France). Methods We performed a retrospective review of the first 23 patients, treated consecutively between September 2010 and June 2012. Results Nine patients underwent total thyroidectomy and 14 patients lobectomies. All procedures were completed successfully with a mean total operative time of 134 min. We observed a single case of internal jugular vein injury during the console time. No instances of persistent complications were observed; however, minor postoperative events occurred in 5 patients. Pathological diagnoses included benign follicular adenoma in 18 patients, benign adenoma with lymphoid thyroiditis in 1 patient, and benign adenoma with Graves' disease in 4 patients. Conclusions Robotic thyroid surgery is feasible in European patients and can be safely performed on selected patients. This technique has infrequent minor complications and provides a high level of satisfaction. PMID:24783048

  19. 850-nm implanted and oxide VCSELs in multigigabit data communication application

    NASA Astrophysics Data System (ADS)

    Pan, Jin-Shan; Lin, Yung-Sen; Li, Chao-Fang A.; Lai, Horng-Ching; Wu, Chang-Cherng; Huang, Kai-Feng

    2001-10-01

    In this paper, we will present the results of the 850nm implanted and oxide-confined vertical cavity surface emitting lasers in multi-Gigabit application. In TrueLight, we have a lot of experience in manufacturing VCSEL with ion-implantation and wet-oxidation technologies for single device Gigabit data transmission application. The ion-implanted VCSEL is reliable with the Mean Time To Failure (MTTF) up to 108 hours at room temperature operation. For the gigabit Ethernet data communication, it provides a very promising solution in short haul application. In transmission experiment we demonstrated the devices could be modulated up to 2.5Gbps and 3.2Gbps data rate. For oxide-confined VCSEL devices, we use wet oxidation technology to approach the device processing and get very good result to achieve the mutli-gigabit data communication application in single device form. The VCSEL device with oxide aperture around 12um could be modulated up to 2.5Gbps and 3.2Gbps. A data of employing VCSEL in high data rate POF transmission is also presented.

  20. Some Aspects on the Mechanical Analysis of Micro-Shutters

    NASA Technical Reports Server (NTRS)

    Fettig, Rainer K.; Kuhn, Jonathan L.; Moseley, S. Harvey; Kutyrev, Alexander S.; Orloff, Jon; Lu, Shude

    1999-01-01

    An array of individually addressable micro-shutters is being designed for spectroscopic applications. Details of the design are presented in a companion paper. The mechanical design of a single shutter element has been completed. This design consists of a shutter blade suspended on a torsion beam manufactured out of single crystal silicon membranes. During operation the shutter blade will be rotated by 90 degrees out of the array plane. Thus, the stability and durability of the beams are crucial for the reliability of the devices. Structures were fabricated using focused ion beam milling in a FEI 620 dual beam machine, and subsequent testing was completed using the same platform. This allowed for short turn around times. We performed torsion and bending experiments to determine key characteristics of the membrane material. Results of measurements on prototype shutters were compared with the predictions of the numerical models. The data from these focused studies were used in conjunction with experiments and numerical models of shutter prototypes to optimize the design. In this work, we present the results of the material studies, and assess the mechanical performance of the resulting design.

  1. A molecular logic gate

    PubMed Central

    Kompa, K. L.; Levine, R. D.

    2001-01-01

    We propose a scheme for molecule-based information processing by combining well-studied spectroscopic techniques and recent results from chemical dynamics. Specifically it is discussed how optical transitions in single molecules can be used to rapidly perform classical (Boolean) logical operations. In the proposed way, a restricted number of states in a single molecule can act as a logical gate equivalent to at least two switches. It is argued that the four-level scheme can also be used to produce gain, because it allows an inversion, and not only a switching ability. The proposed scheme is quantum mechanical in that it takes advantage of the discrete nature of the energy levels but, we here discuss the temporal evolution, with the use of the populations only. On a longer time range we suggest that the same scheme could be extended to perform quantum logic, and a tentative suggestion, based on an available experiment, is discussed. We believe that the pumping can provide a partial proof of principle, although this and similar experiments were not interpreted thus far in our terms. PMID:11209046

  2. Comparison of postoperative pain after root canal treatment using reciprocating instruments based on operator’s experience: A prospective clinical study

    PubMed Central

    Duran-Sindreu, Fernando; Calvo, Carmen; Basilio, Juan; Abella, Fransesc; Ali, Akram; Roig, Miguel; Olivieri, Juan-Gonzalo

    2017-01-01

    Background The aim of the present study was to compare clinically the incidence of postoperative pain after endodontic treatment using the Reciproc System, taking into account the operator’s experience. Material and Methods One hundred patients scheduled for routine endodontic treatment were enrolled in this study. Endodontic treatment was carried out in a single visit by undergraduate and postgraduate students. The chemomechanical preparation of root canals was performed with Reciproc instruments. Pretreatment and postoperative pain was recorded using a visual analogue scale (VAS). Postoperative pain and the need for analgesic consumption were assessed at 4, 8, 16, 24, 48 and 72 hours post-treatment. The data were analyzed using the Mann–Whitney U and Chi-Square test, and the significance was set at P<0.05. Results The mean value of pain after root canal treatment was 1.13±1.94 and 1.91±2.07 on a VAS between 0 and 10 in treatments performed by undergraduate and postgraduate students, respectively. There was a significant difference in the incidence of postoperative pain between the two groups (P<0.05). Conclusions The prevalence of postoperative pain was high in the treatments performed by postgraduate students in comparison with undergraduate students. This suggests that operator experience has an influence on the prevalence of postoperative pain after root canal treatment. Key words:Post-endodontic pain, root canal treatment, reciprocating systems, Expert operators Inexperienced operators. PMID:28828152

  3. Routine use of chest radiographs in the post-operative management of pectus bar removal: necessity or futility.

    PubMed

    Poola, Ashwini Suresh; Rentea, Rebecca M; Weaver, Katrina L; St Peter, Shawn David

    2017-05-01

    While there is literature on techniques for pectus bar removal, there are limited reports on post-operative management. This can include obtaining a postoperative chest radiograph (CXR) despite the minimal risk of associated intra-thoracic complications. This is a review of our experience with bar removal and lack of routine post-operative CXR. A single institution retrospective chart review was performed from 2000 to 2015. Patients who underwent a pectus bar removal procedure were included. We assessed operative timing of bar placement and removal, procedure length, intra-operative and post-operative complications and post-operative CXR findings, specifically the rate of pneumothoraces. 450 patients were identified in this study. Median duration of bar placement prior to removal was 35 months (interquartile range 30 and 36 months). Sixtey-four patients obtained a post-operative CXR. Of these, only one (58%) film revealed a pneumothorax; this was not drained. A CXR was not obtained in 386 (86%) patients with no immediate or delayed complications from this practice. Median follow-up time for all patients was 11 months (interquartile range 7.5-17 months). The risk for a clinically relevant pneumothorax is minimal following bar removal. This suggests that not obtaining routine imaging following bar removal may be a safe practice.

  4. Proposed evaluation framework for assessing operator performance with multisensor displays

    NASA Technical Reports Server (NTRS)

    Foyle, David C.

    1992-01-01

    Despite aggressive work on the development of sensor fusion algorithms and techniques, no formal evaluation procedures have been proposed. Based on existing integration models in the literature, an evaluation framework is developed to assess an operator's ability to use multisensor, or sensor fusion, displays. The proposed evaluation framework for evaluating the operator's ability to use such systems is a normative approach: The operator's performance with the sensor fusion display can be compared to the models' predictions based on the operator's performance when viewing the original sensor displays prior to fusion. This allows for the determination as to when a sensor fusion system leads to: 1) poorer performance than one of the original sensor displays (clearly an undesirable system in which the fused sensor system causes some distortion or interference); 2) better performance than with either single sensor system alone, but at a sub-optimal (compared to the model predictions) level; 3) optimal performance (compared to model predictions); or, 4) super-optimal performance, which may occur if the operator were able to use some highly diagnostic 'emergent features' in the sensor fusion display, which were unavailable in the original sensor displays. An experiment demonstrating the usefulness of the proposed evaluation framework is discussed.

  5. Operations Studies of the Gyrotrons on DIII-D

    NASA Astrophysics Data System (ADS)

    Storment, Stephen; Lohr, John; Cengher, Mirela; Gorelov, Yuri; Ponce, Dan; Torrezan, Antonio

    2017-10-01

    The gyrotrons are high power vacuum tubes used in fusion research to provide high power density heating and current drive in precisely localized areas of the plasma. Despite the increasing experience with both the manufacture and operation of these devices, individual gyrotrons with similar design and manufacturing processes can exhibit important operational differences in terms of generated rf power, efficiency and lifetime. This report discusses differences in the performance of several gyrotrons in operation at DIII-D and presents the results of a series of measurements that could lead to improved the performance of single units based on a better understanding of the causes of these differences. The rf power generation efficiency can be different from gyrotron to gyrotron. In addition, the power loading of the collector can feature localized hot spots, where the collector can locally be close to the power deposition limits. Measurements of collector power loading provide maps of the power deposition and can provide understanding of the effect of modulation of the output rf beam on the total loading, leading to improved operational rules increasing the safety margins for the gyrotrons under different operational scenarios. Work supported by US DOE under DE-FC02-04ER54698.

  6. Agreement between pre-operative and intra-operative bacteriological samples in 85 chronic peri-prosthetic infections.

    PubMed

    Matter-Parrat, V; Ronde-Oustau, C; Boéri, C; Gaudias, J; Jenny, J-Y

    2017-04-01

    Whether pre-operative microbiological sampling contributes to the management of chronic peri-prosthetic infection remains controversial. We assessed agreement between the results of pre-operative and intra-operative samples in patients undergoing single-stage prosthesis exchange to treat chronic peri-prosthetic infection. Agreement between pre-operative and intra-operative samples exceeds 75% in patients undergoing single-stage exchange of a hip or knee prosthesis to treat chronic peri-prosthetic infection. This single-centre retrospective study included 85 single-stage prosthesis exchange procedures in 82 patients with chronic peri-prosthetic infection at the hip or knee. Agreement between pre-operative and intra-operative sample results was evaluated. Changes to the initial antibiotic regimen made based on the intra-operative sample results were recorded. Of 149 pre-operative samples, 109 yielded positive cultures, in 75/85 cases. Of 452 intra-operative samples, 354 yielded positive cultures, in 85/85 cases. Agreement was complete in 54 (63%) cases and partial in 9 (11%) cases; there was no agreement in the remaining 22 (26%) cases. The complete agreement rate was significantly lower than 75% (P=0.01). The initial antibiotic regimen was inadequate in a single case. Pre-operative sampling may contribute to the diagnosis of peri-prosthetic infection but is neither necessary nor sufficient to confirm the diagnosis and identify the causative agent. The spectrum of the initial antibiotic regimen cannot be safely narrowed based on the pre-operative sample results. We suggest the routine prescription of a probabilistic broad-spectrum antibiotic regimen immediately after the prosthesis exchange, even when a pathogen was identified before surgery. IV, retrospective study. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  7. Compact submicrosecond, high current generator for wire explosion experiments

    NASA Astrophysics Data System (ADS)

    Aranchuk, L. E.; Chuvatin, A. S.; Larour, J.

    2004-01-01

    The PIAF generator was designed for low total energy and high energy density experiments with liners, X-pinch or fiber Z-pinch loads. These studies are of interest for such applications as surface and material science, microscopy of biological specimens, lithography of x-ray sensitive resists, and x-ray backlighting of pulsed-power plasmas. The generator is based on an RLC circuit that includes six NWL 180 nF-50 kV capacitors that store up to 1.3 kJ. The capacitors are connected in parallel to a single multispark switch designed to operate at atmospheric pressure. The switch allows reaching a time delay between the trigger pulse and the current pulse of less than 80 ns and has jitter of 6 ns. The total inductance without a load compartment was optimized to be as low as 16 nH, which leads to extremely low impedance of ˜0.12 Ω. A 40 kV initial voltage provides 250 kA maximum current in a 6 nH inductive load with a 180 ns current rise time. PIAF has dimensions of 660×660×490 mm and weight of less than 100 kg, thus manifesting itself as robust, simple to operate, and cost effective. A description of the PIAF generator and the initial experimental results on PIAF with an X-pinch type load are reported. The generator was demonstrated to operate successfully with an X-pinch type load. The experiments first started with investigation of the previously unexplored X-pinch conduction time range, 100 ns-1 μs. A single short radiation pulse was obtained that came from a small, point-like plasma. The following x-ray source characteristics were achieved: typical hot spot size of 50-100 μm, radiation pulse duration of 1.5-2 ns, and radiation yield of about 250-500 mJ in the softer spectral range (hν⩾700 eV) and 50-100 mJ in the harder one (hν⩾1 keV). These results provide the potential for further application of this source, such as use as a backlight diagnostic tool.

  8. Focused Rocket-Ejector RBCC Experiments

    NASA Technical Reports Server (NTRS)

    Santoro, Robert J.; Pal, Sibtosh

    2003-01-01

    This document reports the results of additional efforts for the Rocket Based Combined Cycle (RBCC) rocket-ejector mode research work carried out at the Perm State Propulsion Engineering Research Center in support of NASA s technology development efforts for enabling 3rd generation Reusable Launch Vehicles (RLV). The two tasks conducted under this program build on earlier NASA MSFC funded research program on rocket ejector investigations. The first task continued a systematic investigation of the improvements provided by a gaseous hydrogen (GHz)/oxygen (GO2) twin thruster RBCC rocket ejector system over a single rocket system. In a similar vein, the second task continued investigations into the performance of a hydrocarbon (liquid JP-7)/gaseous oxygen single thruster rocket-ejector system. To gain a systematic understanding of the rocket-ejector s internal fluid mechanic/combustion phenomena, experiments were conducted with both direct-connect and sea-level static diffusion and afterburning (DAB) configurations for a range of rocket operating conditions. For all experimental conditions, overall system performance was obtained through global measurements of wall static pressure profiles, heat flux profiles and engine thrust. For the GH2/GO2 propellant rocket ejector experiments, high frequency measurements of the pressure field within the system were also made to understand the unsteady behavior of the flowfield.

  9. Preliminary analyses of WL experiment No. 701, space environment effects on operating fiber optic systems

    NASA Technical Reports Server (NTRS)

    Taylor, E. W.; Berry, J. N.; Sanchez, A. D.; Padden, R. J.; Chapman, S. P.

    1992-01-01

    A brief overview of the analyses performed to date on WL Experiment-701 is presented. Four active digital fiber optic links were directly exposed to the space environment for a period of 2114 days. The links were situated aboard the Long Duration Exposure Facility (LDEF) with the cabled, single fiber windings atop an experimental tray containing instrumentation for exercising the experiment in orbit. Despite the unplanned and prolonged exposure to trapped and galactic radiation, wide temperature extremes, atomic oxygen interactions, and micro-meteorite and debris impacts, in most instances the optical data links performed well within the experimental limits. Analysis of the recorded orbital data clearly indicates that fiber optic applications in space will meet with success. Ongoing tests and analysis of the experiment at the Phillips Laboratory's Optoelectronics Laboratory will expand this premise, and establish the first known and extensive database of active fiber optic link performance during prolonged space exposure. WL Exp-701 was designed as a feasibility demonstration for fiber optic technology in space applications, and to study the performance of operating fiber systems exposed to space environmental factors such as galactic radiation, and wide temperature cycling. WL Exp-701 is widely acknowledged as a benchmark accomplishment that clearly demonstrates, for the first time, that fiber optic technology can be successfully used in a variety of space applications.

  10. Push versus pull gastrostomy in cancer patients: A single center retrospective analysis of complications and technical success rates.

    PubMed

    Currie, B M; Getrajdman, G I; Covey, A M; Alago, W; Erinjeri, J P; Maybody, M; Boas, F E

    2018-04-28

    To compare the technical success and complication rates of push versus pull gastrostomy tubes in cancer patients, and to examine their dependence on operator experience. A retrospective review was performed of 304 cancer patients (170 men, 134 women; mean age 60.3±12.6 [SD], range: 19-102 years) referred for primary gastrostomy tube placement, 88 (29%) of whom had a previously unsuccessful attempt at percutaneous endoscopic gastrostomy (PEG) placement. Analyzed variables included method of insertion (push versus pull), indication for gastrostomy, technical success, operator experience, and procedure-related complications within 30 days of placement. Gastrostomy tubes were placed for feeding in 189 patients and palliative decompression in 115 patients. Technical success was 91%: 78% after endoscopy had previously been unsuccessful and 97% when excluding failures associated with prior endoscopy. In the first 30 days, there were 29 minor complications (17.2%) associated with push gastrostomies, and only 8 minor complications (7.5%) with pull gastrostomies (P<0.05). There was no significant difference in major complications (push gastrostomy 5.3%, pull gastrostomy 5.6%). For decompressive gastrostomy tubes, the pull technique resulted in lower rates of both minor and major complications. There was no difference in complications or technical success rates for more versus less experienced operators. Pull gastrostomy tube placement had a lower rate of complications than push gastrostomy tube placement, especially when the indication was decompression. The technical success rate was high, even after a failed attempt at endoscopic placement. Both the rates of success and complications were independent of operator experience. Copyright © 2018 Société française de radiologie. Published by Elsevier Masson SAS. All rights reserved.

  11. 75 FR 23588 - Drawbridge Operation Regulation; Atlantic Intracoastal Waterway, Riviera Beach, FL

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-04

    .... This deviation allows the bridge to be placed on single- leaf operations. Double-leaf operations will... of Transportation requests a deviation allowing for single-leaf operations from May 10, 2010 through October 31, 2010. Double-leaf openings will be available with a four hour notice to the bridge tender...

  12. [Medial Unicompartmental Knee Arthroplasty Using Patient-Specific Instrumentation - Accuracy of Preoperative Planning, Time Saving and Cost Efficiency].

    PubMed

    Seeber, G H; Kolbow, K; Maus, U; Kluge, A; Lazovic, D

    2016-06-01

    In the past few years, patient-specific instrumentation (PSI) in knee endoprosthetics has been energetically marketed. PSI can enhance the accuracy of the size and alignment of the prosthesis components. It should also be possible to reduce hospital costs and operating time. It remains unclear whether these putative advantages are achieved in medial unicompartmental knee arthroplasty (UKA). Data from 22 patients (24 knees) were analysed retrospectively. The focus was on the reliability of preoperative surgical planning - particularly with regards to the level of experience of the five surgeons involved, who were split into two groups depending on their level of experience, as defined by EndoCert®. Another focus was on the evaluation of actual surgical time and cost effectiveness using PSI. In order to achieve an optimal outcome, preoperative surgical planning had to be modified intraoperatively to a great extent. The femoral component had to be adjusted intraoperatively in 41.7 % of all cases, the tibial component in 58.3 % and the polyethylene insert in 87.5 %. Surgeons equipped with less experience had to change preoperative planning more often than the more experienced surgeons. Utilising PSI increased the operating time of both the less experienced and the more experienced surgeons. PSI planning and lack of surgical experience were the main predictors of increased surgical time. Instead of lowering costs, utilizing PSI increased surgical costs by nearly 1300 $ per case. This was due to increased operating time, license fees and extraordinary expenditure for MRI scans. The advertised advantages of PSI were not supported by the data analysed. On the contrary, this technology leads to additional costs, greater operating time and insufficient accuracy in preoperative planning. As not a single study has yet demonstrated better outcomes in terms of alignment and/or function with PSI than with standard instrumentation, additional data are required before PSI can be recommended for routine use in medial UKA. Georg Thieme Verlag KG Stuttgart · New York.

  13. Conducting Research on the International Space Station Using the EXPRESS Rack Facilities

    NASA Technical Reports Server (NTRS)

    Thompson, Sean W.; Lake, Robert E.

    2013-01-01

    Conducting Research on the International Space Station using the EXPRESS Rack Facilities. Sean W. Thompson and Robert E. Lake. NASA Marshall Space Flight Center, Huntsville, AL, USA. Eight "Expedite the Processing of Experiments to Space Station" (EXPRESS) Rack facilities are located within the International Space Station (ISS) laboratories to provide standard resources and interfaces for the simultaneous and independent operation of multiple experiments within each rack. Each EXPRESS Rack provides eight Middeck Locker Equivalent locations and two drawer locations for powered experiment equipment, also referred to as sub-rack payloads. Payload developers may provide their own structure to occupy the equivalent volume of one, two, or four lockers as a single unit. Resources provided for each location include power (28 Vdc, 0-500 W), command and data handling (Ethernet, RS-422, 5 Vdc discrete, +/- 5 Vdc analog), video (NTSC/RS 170A), and air cooling (0-200 W). Each rack also provides water cooling (500 W) for two locations, one vacuum exhaust interface, and one gaseous nitrogen interface. Standard interfacing cables and hoses are provided on-orbit. One laptop computer is provided with each rack to control the rack and to accommodate payload application software. Four of the racks are equipped with the Active Rack Isolation System to reduce vibration between the ISS and the rack. EXPRESS Racks are operated by the Payload Operations Integration Center at Marshall Space Flight Center and the sub-rack experiments are operated remotely by the investigating organization. Payload Integration Managers serve as a focal to assist organizations developing payloads for an EXPRESS Rack. NASA provides EXPRESS Rack simulator software for payload developers to checkout payload command and data handling at the development site before integrating the payload with the EXPRESS Functional Checkout Unit for an end-to-end test before flight. EXPRESS Racks began supporting investigations onboard ISS on April 24, 2001 and will continue through the life of the ISS.

  14. Comparison of chain sampling plans with single and double sampling plans

    NASA Technical Reports Server (NTRS)

    Stephens, K. S.; Dodge, H. F.

    1976-01-01

    The efficiency of chain sampling is examined through matching of operating characteristics (OC) curves of chain sampling plans (ChSP) with single and double sampling plans. In particular, the operating characteristics of some ChSP-0, 3 and 1, 3 as well as ChSP-0, 4 and 1, 4 are presented, where the number pairs represent the first and the second cumulative acceptance numbers. The fact that the ChSP procedure uses cumulative results from two or more samples and that the parameters can be varied to produce a wide variety of operating characteristics raises the question whether it may be possible for such plans to provide a given protection with less inspection than with single or double sampling plans. The operating ratio values reported illustrate the possibilities of matching single and double sampling plans with ChSP. It is shown that chain sampling plans provide improved efficiency over single and double sampling plans having substantially the same operating characteristics.

  15. Autonomous learning based on cost assumptions: theoretical studies and experiments in robot control.

    PubMed

    Ribeiro, C H; Hemerly, E M

    2000-02-01

    Autonomous learning techniques are based on experience acquisition. In most realistic applications, experience is time-consuming: it implies sensor reading, actuator control and algorithmic update, constrained by the learning system dynamics. The information crudeness upon which classical learning algorithms operate make such problems too difficult and unrealistic. Nonetheless, additional information for facilitating the learning process ideally should be embedded in such a way that the structural, well-studied characteristics of these fundamental algorithms are maintained. We investigate in this article a more general formulation of the Q-learning method that allows for a spreading of information derived from single updates towards a neighbourhood of the instantly visited state and converges to optimality. We show how this new formulation can be used as a mechanism to safely embed prior knowledge about the structure of the state space, and demonstrate it in a modified implementation of a reinforcement learning algorithm in a real robot navigation task.

  16. Experiment/Analytical Characterization of the RBCC Rocket-Ejector Mode

    NASA Technical Reports Server (NTRS)

    Ruf, J. H.; Lehman, M.; Pal, S.; Santoro, R. J.; West, J.; Turner, James E. (Technical Monitor)

    2000-01-01

    Experimental and complementary CFD results from the study of the rocket-ejector mode of a Rocket Based Combined Cycle (RBCC) engine are presented and discussed. The experiments involved systematic flowfield measurements in a two-dimensional, variable geometry rocket-ejector system. The rocket-ejector system utilizes a single two-dimensional, gaseous oxygen/gaseous hydrogen rocket as the ejector. To gain a thorough understanding of the rocket-ejector's internal fluid mechanic/combustion phenomena, experiments were conducted with both direct-connect and sea-level static configurations for a range of rocket operating conditions. Overall system performance was obtained through global measurements of wall static pressure profiles, heat flux profiles and engine thrust, whereas detailed mixing and combustion information was obtained through Raman spectroscopy measurements of major species (oxygen, hydrogen, nitrogen and water vapor). The experimental results for both the direct-connect and sea-level static configurations are compared with CFD predictions of the flowfield.

  17. Constraining neutrinos as background to wimp-nucleon dark matter particle searches for DaMIC: CCD physics analysis and electronics development

    NASA Astrophysics Data System (ADS)

    Butner, Melissa Jean

    The DaMIC (Dark Matter in CCDs) experiment searches for dark matter particles using charge coupled devices (CCDs) operated at a low detection threshold of ˜40 eV electron equivalent energy (eVee). A multiplexor board is tested for DAMIC100+ which has the ability to control up to 16 CCDs at one time allowing for the selection of a single CCD for readout while leaving all others static and maintaining sub-electron noise. A dark matter limit is produced using the results of physics data taken with the DAMIC experiment. Next, the contribution from neutrino-nucleus coherent scattering is investigated using data from the Coherent Neutrino Nucleus Interaction Experiment (CONnuIE) using the same CCD technology. The results are used to explore the performance of CCD detectors that ultimately will limit the ability to differentiate incident solar and atmospheric neutrinos from dark matter particles.

  18. Status and Plans for the FLARE (Facility for Laboratory Reconnection Experiments) Project

    NASA Astrophysics Data System (ADS)

    Ji, H.; Bhattacharjee, A.; Prager, S.; Daughton, W.; Bale, S.; Carter, T.; Crocker, N.; Drake, J.; Egedal, J.; Sarff, J.; Wallace, J.; Chen, Y.; Cutler, R.; Fox, W.; Heitzenroeder, P.; Kalish, M.; Jara-Almonte, J.; Myers, C.; Ren, Y.; Yamada, M.; Yoo, J.

    2015-11-01

    The FLARE device (flare.pppl.gov) is a new intermediate-scale plasma experiment under construction at Princeton to study magnetic reconnection in regimes directly relevant to space, solar, astrophysical, and fusion plasmas. The existing small-scale experiments have been focusing on the single X-line reconnection process either with small effective sizes or at low Lundquist numbers, but both of which are typically very large in natural and fusion plasmas. The design of the FLARE device is motivated to provide experimental access to the new regimes involving multiple X-lines, as guided by a reconnection ``phase diagram'' [Ji & Daughton, PoP (2011)]. Most of major components of the FLARE device have been designed and are under construction. The device will be assembled and installed in 2016, followed by commissioning and operation in 2017. The planned research on FLARE as a user facility will be discussed. Supported by NSF.

  19. A Novel MUMPs-compatible single-layer out-of-plane electrothermal actuator

    NASA Astrophysics Data System (ADS)

    Tang, Weider; Wu, Mingching; Ho, Yi-Ping; Yeh, Mau-Shium; Fang, Weileun

    2002-11-01

    Microactuator is one of the key components for the microelectromechanical systems (MEMS), and it can be categorized as out-of-plane and in-plane according to the motion types. Most of the existing out-of-plane thermal actuators are multi-layer structures. In this paper, a novel electrothermal single-layer out-of-plane actuator is provided and it characteristics and advantages of this device are stated as follows: (1) This actuator is consisted of only a single thin film material, therefore, it can prevent from delaminating after a long-term operation. Besides, owing to its symmetric geometric design, the inner-beams of this structure don"t have any current passed through them and the inner-beams also provide a geometric constraint to allow the two free ends of the structure to bend upwards symmetrically. (2) This device can be operated at a relative low voltage (<5 volt), and deflected upwards about 4 μm in the experiment test. Besides, the fabrication process is very simple and it is MUMPs(Multi-User MEMS Processes)-compatible. Presently, a prototype structure has been successfully fabricated and tested. This structure offers the potential applications in the adaptive optics systems, and Fabry-Perot filters, etc. Besides, it also provides an interface to cooperate with integrated circuits (IC) and various optical elements to construct an embedded-control optical system.

  20. Continuous single pulse resolved measurement of beam diameters at 200 kHz using optical transmission filters

    NASA Astrophysics Data System (ADS)

    Fruechtenicht, Johannes; Letsch, Andreas; Voss, Andreas; Abdou Ahmed, Marwan; Graf, Thomas

    2012-02-01

    We present a novel laser beam measurement setup which allows the determination of the beam diameter for each single pulse of a pulsed laser beam at repetition rates of up to 200 kHz. This is useful for online process-parameter control e.g. in micromachining or for laser source characterization. Basically, the developed instrument combines spatial transmission filters specially designed for instantaneous optical determination of the second order moments of the lateral intensity distribution of the light beam and photodiodes coupled to customized electronics. The acquisition is computer-based, enabling real-time operation for online monitoring or control. It also allows data storage for a later analysis and visualization of the measurement results. The single-pulse resolved beam diameter can be measured and recorded without any interruption for an unlimited number of pulses. It is only limited by the capacity of the data storage means. In our setup a standard PC and hard-disk provided 2 hours uninterrupted operation and recording of varying beam diameters at 200 kHz. This is about three orders of magnitude faster than other systems. To calibrate our device we performed experiments in cw and pulsed regimes and the obtained results were compared to those obtained with a commercial camera based system. Only minor deviations of the beam diameter values between the two instruments were observed, proving the reliability of our approach.

Top