14 CFR 417.309 - Flight safety system analysis.
Code of Federal Regulations, 2012 CFR
2012-01-01
... system anomaly occurring and all of its effects as determined by the single failure point analysis and... termination system. (c) Single failure point. A command control system must undergo an analysis that... fault tree analysis or a failure modes effects and criticality analysis; (2) Identify all possible...
14 CFR 417.309 - Flight safety system analysis.
Code of Federal Regulations, 2010 CFR
2010-01-01
... system anomaly occurring and all of its effects as determined by the single failure point analysis and... termination system. (c) Single failure point. A command control system must undergo an analysis that... fault tree analysis or a failure modes effects and criticality analysis; (2) Identify all possible...
14 CFR 417.309 - Flight safety system analysis.
Code of Federal Regulations, 2013 CFR
2013-01-01
... system anomaly occurring and all of its effects as determined by the single failure point analysis and... termination system. (c) Single failure point. A command control system must undergo an analysis that... fault tree analysis or a failure modes effects and criticality analysis; (2) Identify all possible...
14 CFR 417.309 - Flight safety system analysis.
Code of Federal Regulations, 2014 CFR
2014-01-01
... system anomaly occurring and all of its effects as determined by the single failure point analysis and... termination system. (c) Single failure point. A command control system must undergo an analysis that... fault tree analysis or a failure modes effects and criticality analysis; (2) Identify all possible...
14 CFR 417.309 - Flight safety system analysis.
Code of Federal Regulations, 2011 CFR
2011-01-01
... system anomaly occurring and all of its effects as determined by the single failure point analysis and... termination system. (c) Single failure point. A command control system must undergo an analysis that... fault tree analysis or a failure modes effects and criticality analysis; (2) Identify all possible...
14 CFR 31.19 - Performance: Uncontrolled descent.
Code of Federal Regulations, 2010 CFR
2010-01-01
... single failure of the heater assembly, fuel cell system, gas value system, or maneuvering vent system, or from any single tear in the balloon envelope between tear stoppers: (1) The maximum vertical velocity attained. (2) The altitude loss from the point of failure to the point at which maximum vertical velocity...
NASA Technical Reports Server (NTRS)
Chen, Dakai; Phan, Anthony; Kim, Hak; Swonger, James; Musil, Paul; LaBel, Kenneth
2013-01-01
We show examples of single event functional interrupt and destructive failure in modern POL devices. The increasing complexity and diversity of the design and process introduce hard SEE modes that are triggered by various mechanisms.
1981-01-01
are applied to determine what system states (usually failed states) are possible; deductive methods are applied to determine how a given system state...Similar considerations apply to the single failures of CVA, BVB and CVB and this important additional information has been displayed in the principal...way. The point "maximum tolerable failure" corresponds to the survival point of the company building the aircraft. Above that point, only intolerable
NASA Astrophysics Data System (ADS)
McCrea, Terry
The Shuttle Processing Contract (SPC) workforce consists of Lockheed Space Operations Co. as prime contractor, with Grumman, Thiokol Corporation, and Johnson Controls World Services as subcontractors. During the design phase, reliability engineering is instrumental in influencing the development of systems that meet the Shuttle fail-safe program requirements. Reliability engineers accomplish this objective by performing FMEA (failure modes and effects analysis) to identify potential single failure points. When technology, time, or resources do not permit a redesign to eliminate a single failure point, the single failure point information is formatted into a change request and presented to senior management of SPC and NASA for risk acceptance. In parallel with the FMEA, safety engineering conducts a hazard analysis to assure that potential hazards to personnel are assessed. The combined effort (FMEA and hazard analysis) is published as a system assurance analysis. Special ground rules and techniques are developed to perform and present the analysis. The reliability program at KSC is vigorously pursued, and has been extremely successful. The ground support equipment and facilities used to launch and land the Space Shuttle maintain an excellent reliability record.
Durham, Myra E; Sod, Gary A; Riggs, Laura M; Mitchell, Colin F
2015-02-01
To compare the monotonic biomechanical properties of a broad 4.5 mm limited contact-dynamic compression plate (LC-DCP) fixation secured with hydroxyapatite (HA) coated cortical bone screws (HA-LC-DCP) versus uncoated cortical bone screws (AO-LC-DCP) to repair osteotomized equine 3rd metacarpal (MC3) bones. Experimental. Adult equine cadaveric MC3 bones (n = 12 pair). Twelve pairs of equine MC3 were divided into 3 test groups (4 pairs each) for: (1) 4 point bending single cycle to failure testing; (2) 4 point bending cyclic fatigue testing; and (3) torsional single cycle to failure testing. For the HA-LC-DCP-MC3 construct, an 8-hole broad LC-DCP (Synthes Ltd, Paoli, PA) was secured on the dorsal surface of each randomly selected MC3 bone with a combination of four 5.5 mm and four 4.5 mm HA-coated cortical screws. For the AO-LC-DCP-MC3 construct, an 8-hole 4.5 mm broad LC-DCP was secured on the dorsal surface of the contralateral MC3 bone with a combination of four 5.5 mm and four 4.5 mm uncoated cortical screws. All MC3 bones had mid-diaphyseal osteotomies. Mean test variable values for each method were compared using a paired t-test within each group. Significance was set at P < .05. Mean yield load, yield bending moment, composite rigidity, failure load, and failure bending moment, under 4 point bending, single cycle to failure, of the HA-LC-DCP fixation were significantly greater than those of the AO-LC-DCP fixation. Mean ± SD values for the HA-LC-DCP and the AO-LC-DCP fixation techniques, respectively, in single cycle to failure under 4 point bending were: yield load, 26.7 ± 2.15 and 16.3 ± 1.38 kN; yield bending moment, 527.4 ± 42.4 and 322.9 ± 27.2 N-m; composite rigidity, 5306 ± 399 and 3003 ± 300 N-m/rad; failure load, 40.6 ± 3.94 and 26.5 ± 2.52 kN; and failure bending moment, 801.9 ± 77.9 and 522.9 ± 52.2 N-m. Mean cycles to failure in 4 point bending of the HA-LC-DCP fixation (116,274 ± 13,211) was significantly greater than that of the AO-LC-DCP fixation 47,619 ± 6580. Mean yield load, mean composite rigidity, and mean failure load under torsional testing, single cycle to failure was significantly greater for the broad HA-LC-DCP fixation compared with the AO-LC-DCP fixation. In single cycle to failure under torsion, mean ± SD values for the HA-LC-DCP and the AO-LC-DCP fixation techniques, respectively, were: yield load, 101.3 ± 14.68 and 70.54 ± 10.20 N-m; composite rigidity, 437.9 ± 32.9 and 220.7 ± 17.6 N-m/rad; and failure load: 105.7 ± 15.5 and 75.28 ± 10.1 N-m. HA-LC-DCP was superior to AO-LC-DCP in resisting the static overload forces (palmarodorsal 4 point bending and torsional) and in resisting cyclic fatigue under palmarodorsal 4 point bending. © Copyright 2014 by The American College of Veterinary Surgeons.
2009-06-01
to floating point , to multi-level logic. 2 Overview Self-aware computation can be distinguished from existing computational models which are...systems have advanced to the point that the time is ripe to realize such a system. To illustrate, let us examine each of the key aspects of self...servers for each service, there are no single points of failure in the system. If an OS or user core has a failure, one of several introspection cores
NASA Technical Reports Server (NTRS)
Ellsworth, Joel C.
2017-01-01
During flight-testing of the National Aeronautics and Space Administration (NASA) Gulfstream III (G-III) airplane (Gulfstream Aerospace Corporation, Savannah, Georgia) SubsoniC Research Aircraft Testbed (SCRAT) between March 2013 and April 2015 it became evident that the sensor array used for stagnation point detection was not functioning as expected. The stagnation point detection system is a self calibrating hot-film array; the calibration was unknown and varied between flights, however, the channel with the lowest power consumption was expected to correspond with the point of least surface shear. While individual channels showed the expected behavior for the hot-film sensors, more often than not the lowest power consumption occurred at a single sensor (despite in-flight maneuvering) in the array located far from the expected stagnation point. An algorithm was developed to process the available system output and determine the stagnation point location. After multiple updates and refinements, the final algorithm was not sensitive to the failure of a single sensor in the array, but adjacent failures beneath the stagnation point crippled the algorithm.
Larsen, Jacob M; Hjortshøj, Søren P; Nielsen, Jens C; Johansen, Jens B; Petersen, Helen H; Haarbo, Jens; Johansen, Martin B; Thøgersen, Anna Margrethe
2016-03-01
The best choice of defibrillator lead in patients with routine implantable cardioverter-defibrillator (ICD) is not settled. Traditionally, most physicians prefer dual-coil leads but the use of single-coil leads is increasing. The purpose of this study was to compare clinical outcomes in patients with single- and dual-coil leads. All 4769 Danish patients 18 years or older with first-time ICD implants from 2007 to 2011 were included from the Danish Pacemaker and ICD Register. Defibrillator leads were 38.9% single-coil leads and 61.1% dual-coil leads. The primary end point was all-cause mortality. Secondary end points were lowest successful energy at implant defibrillation testing, first shock failure in spontaneous arrhythmias, structural lead failure, and lead extraction outcomes. Single-coil leads were associated with lower all-cause mortality with an adjusted hazard ratio of 0.85 (95% confidence interval 0.73-0.99; P = .04). This finding was robust in a supplementary propensity score-matched analysis. However, dual-coil leads were used in patients with slightly higher preimplant morbidity, making residual confounding by indication the most likely explanation for the observed association between lead type and mortality. The lowest successful defibrillation energy was higher using single-coil leads (23.2 ± 4.3 J vs 22.1 ± 3.9 J; P < .001). No significant differences were observed for other secondary end points showing high shock efficacies and low rates of lead failures and extraction complications. Shock efficacy is high for modern ICD systems. The choice between single-coil and dual-coil defibrillator leads is unlikely to have a clinically significant impact on patient outcomes in routine ICD implants. Copyright © 2016 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
Failure propagation in multi-cell lithium ion batteries
Lamb, Joshua; Orendorff, Christopher J.; Steele, Leigh Anna M.; ...
2014-10-22
Traditionally, safety and impact of failure concerns of lithium ion batteries have dealt with the field failure of single cells. However, large and complex battery systems require the consideration of how a single cell failure will impact the system as a whole. Initial failure that leads to the thermal runaway of other cells within the system creates a much more serious condition than the failure of a single cell. This work examines the behavior of small modules of cylindrical and stacked pouch cells after thermal runaway is induced in a single cell through nail penetration trigger [1] within the module.more » Cylindrical cells are observed to be less prone to propagate, if failure propagates at all, owing to the limited contact between neighboring cells. However, the electrical connectivity is found to be impactful as the 10S1P cylindrical cell module did not show failure propagation through the module, while the 1S10P module had an energetic thermal runaway consuming the module minutes after the initiation failure trigger. Modules built using pouch cells conversely showed the impact of strong heat transfer between cells. In this case, a large surface area of the cells was in direct contact with its neighbors, allowing failure to propagate through the entire battery within 60-80 seconds for all configurations (parallel or series) tested. This work demonstrates the increased severity possible when a point failure impacts the surrounding battery system.« less
Control allocation for gimballed/fixed thrusters
NASA Astrophysics Data System (ADS)
Servidia, Pablo A.
2010-02-01
Some overactuated control systems use a control distribution law between the controller and the set of actuators, usually called control allocator. Beyond the control allocator, the configuration of actuators may be designed to be able to operate after a single point of failure, for system optimization and/or decentralization objectives. For some type of actuators, a control allocation is used even without redundancy, being a good example the design and operation of thruster configurations. In fact, as the thruster mass flow direction and magnitude only can be changed under certain limits, this must be considered in the feedback implementation. In this work, the thruster configuration design is considered in the fixed (F), single-gimbal (SG) and double-gimbal (DG) thruster cases. The minimum number of thrusters for each case is obtained and for the resulting configurations a specific control allocation is proposed using a nonlinear programming algorithm, under nominal and single-point of failure conditions.
NASA Technical Reports Server (NTRS)
Greenhalgh, Phillip O.
2004-01-01
In the production of each Space Shuttle Reusable Solid Rocket Motor (RSRM), over 100,000 inspections are performed. ATK Thiokol Inc. reviewed these inspections to ensure a robust inspection system is maintained. The principal effort within this endeavor was the systematic identification and evaluation of inspections considered to be single-point. Single-point inspections are those accomplished on components, materials, and tooling by only one person, involving no other check. The purpose was to more accurately characterize risk and ultimately address and/or mitigate risk associated with single-point inspections. After the initial review of all inspections and identification/assessment of single-point inspections, review teams applied risk prioritization methodology similar to that used in a Process Failure Modes Effects Analysis to derive a Risk Prioritization Number for each single-point inspection. After the prioritization of risk, all single-point inspection points determined to have significant risk were provided either with risk-mitigating actions or rationale for acceptance. This effort gave confidence to the RSRM program that the correct inspections are being accomplished, that there is appropriate justification for those that remain as single-point inspections, and that risk mitigation was applied to further reduce risk of higher risk single-point inspections. This paper examines the process, results, and lessons learned in identifying, assessing, and mitigating risk associated with single-point inspections accomplished in the production of the Space Shuttle RSRM.
Galassi, Alfredo R; Boukhris, Marouane; Azzarelli, Salvatore; Castaing, Marine; Marzà, Francesco; Tomasello, Salvatore D
2016-05-09
The aims of this study were to describe the 10-year experience of a single operator dedicated to chronic total occlusion (CTO) and to establish a model for predicting technical failure. During the last decade, the interest in percutaneous coronary interventions (PCIs) of chronic total occlusions (CTOs) has increased, allowing the improvement of success rate. One thousand nineteen patients with CTO underwent 1,073 CTO procedures performed by a single CTO-dedicated operator. The study population was subdivided into 2 groups by time period: period 1 (January 2005 to December 2009, n = 378) and period 2 (January 2010 to December 2014, n = 641). Observations were randomly assigned to a derivation set and a validation set (in a 2:1 ratio). A prediction score was established by assigning points for each independent predictor of technical failure in the derivation set according to the beta coefficient and summing all points accrued. Lesions attempted in period 2 were more complex in comparison with those in period 1. Compared with period 1, both technical and clinical success rates significantly improved (from 87.8% to 94.4% [p = 0.001] and from 77.6% to 89.9% [p < 0.001], respectively). A prediction score for technical failure including age ≥75 years (1 point), ostial location (1 point), and collateral filling Rentrop grade <2 (2 points) was established, stratifying procedures into 4 difficulty groups: easy (0), intermediate (1), difficult (2), and very difficult (3 or 4), with decreasing technical success rates. In derivation and validation sets, areas under the curve were comparable (0.728 and 0.772, respectively). With growing expertise, the success rate has increased despite increasing complexity of attempted lesions. The established model predicted the probability of technical failure and thus might be applied to grading the difficulty of CTO procedures. Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Michanowicz, Drew R.; Buonocore, Jonathan J.; Rowland, Sebastian T.; Konschnik, Katherine E.; Goho, Shaun A.; Bernstein, Aaron S.
2017-05-01
The leak of processed natural gas (PNG) from October 2015 to February 2016 from the Aliso Canyon storage facility, near Los Angeles, California, was the largest single accidental release of greenhouse gases in US history. The Interagency Task Force on Natural Gas Storage Safety and California regulators recently recommended operators phase out single-point-of-failure (SPF) well designs. Here, we develop a national dataset of UGS well activity in the continental US to assess regulatory data availability and uncertainty, and to assess the prevalence of certain well design deficiencies including single-point-of-failure designs. We identified 14 138 active UGS wells associated with 317 active UGS facilities in 29 states using regulatory and company data. State-level wellbore datasets contained numerous reporting inconsistencies that limited data concatenation. We identified 2715 active UGS wells across 160 facilities that, like the failed well at Aliso Canyon, predated the storage facility, and therefore were not originally designed for gas storage. The majority (88%) of these repurposed wells are located in OH, MI, PA, NY, and WV. Repurposed wells have a median age of 74 years, and the 2694 repurposed wells constructed prior to 1979 are particularly likely to exhibit design-related deficiencies. An estimated 210 active repurposed wells were constructed before 1917—before cement zonal isolation methods were utilized. These wells are located in OH, PA, NY, and WV and represent the highest priority related to potential design deficiencies that could lead to containment loss. This national baseline assessment identifies regulatory data uncertainties, highlights a potentially widespread vulnerability of the natural gas supply chain, and can aid in prioritization and oversight for high-risk wells and facilities.
Bandholm, Thomas; Thorborg, Kristian; Lunn, Troels Haxholdt; Kehlet, Henrik; Jakobsen, Thomas Linding
2014-01-01
Background Loading and contraction failure (muscular exhaustion) are strength training variables known to influence neural activation of the exercising muscle in healthy subjects, which may help reduce neural inhibition of the quadriceps muscle following total knee arthroplasty (TKA). It is unknown how these exercise variables influence knee pain after TKA. Objective To investigate the effect of loading and contraction failure on knee pain during strength training, shortly following TKA. Design Cross-sectional study. Setting Consecutive sample of patients from the Copenhagen area, Denmark, receiving a TKA, between November 2012 and April 2013. Participants Seventeen patients, no more than 3 weeks after their TKA. Main outcome measures: In a randomized order, the patients performed 1 set of 4 standardized knee extensions, using relative loads of 8, 14, and 20 repetition maximum (RM), and ended with 1 single set to contraction failure (14 RM load). The individual loadings (kilograms) were determined during a familiarization session >72 hours prior. The patients rated their knee pain during each repetition, using a numerical rating scale (0–10). Results Two patients were lost to follow up. Knee pain increased with increasing load (20 RM: 3.1±2.0 points, 14 RM: 3.5±1.8 points, 8 RM: 4.3±2.5 points, P = 0.006), and repetitions to contraction failure (10% failure: 3.2±1.9 points, 100% failure: 5.4±1.6 points, P<0.001). Resting knee pain 60 seconds after the final repetition (2.7±2.4 points) was not different from that recorded before strength training (2.7±1.8 points, P = 0.88). Conclusion Both loading and repetitions performed to contraction failure during knee- extension strength-training, increased post-operative knee pain during strength training implemented shortly following TKA. However, only the increase in pain during repetitions to contraction failure exceeded that defined as clinically relevant, and was very short-lived. Trial Registration ClinicalTrials.gov NCT01729520 PMID:24614574
Initial flight results of the TRMM Kalman filter
NASA Technical Reports Server (NTRS)
Andrews, Stephen F.; Morgenstern, Wendy M.
1998-01-01
The Tropical Rainfall Measuring Mission (TRMM) spacecraft is a nadir pointing spacecraft that nominally controls attitude based on the Earth Sensor Assembly (ESA) output. After a potential single point failure in the ESA was identified, the contingency attitude determination method chosen to backup the ESA-based system was a sixth-order extended Kalman filter that uses magnetometer and digital sun sensor measurements. A brief description of the TRMM Kalman filter will be given, including some implementation issues and algorithm heritage. Operational aspects of the Kalman filter and some failure detection and correction will be described. The Kalman filter was tested in a sun pointing attitude and in a nadir pointing attitude during the in-orbit checkout period, and results from those tests will be presented. This paper will describe some lessons learned from the experience of the TRMM team.
Initial Flight Results of the TRMM Kalman Filter
NASA Technical Reports Server (NTRS)
Andrews, Stephen F.; Morgenstern, Wendy M.
1998-01-01
The Tropical Rainfall Measuring Mission (TRMM) spacecraft is a nadir pointing spacecraft that nominally controls attitude based on the Earth Sensor Assembly (ESA) output. After a potential single point failure in the ESA was identified, the contingency attitude determination method chosen to backup the ESA-based system was a sixth-order extended Kalman filter that uses magnetometer and digital sun sensor measurements. A brief description of the TRMM Kalman filter will be given, including some implementation issues and algorithm heritage. Operational aspects of the Kalman filter and some failure detection and correction will be described. The Kalman filter was tested in a sun pointing attitude and in a nadir pointing attitude during the in-orbit checkout period, and results from those tests will be presented. This paper will describe some lessons learned from the experience of the TRMM team.
The Impact of Single-Gender Scheduling on Students in a Title I School
ERIC Educational Resources Information Center
Moss, Janet L.
2011-01-01
This dissertation was designed to examine the impact that single-gender scheduling would have on students who attend a struggling Title I middle school. The importance of the middle level cannot be denied. Strong research points to this time in a student's life as the pivotal crux on which success and failure are balanced. Middle level educators…
Leventhal, Adam M.; Japuntich, Sandra J.; Piper, Megan E.; Jorenby, Douglas E.; Schlam, Tanya R.; Baker, Timothy B.
2012-01-01
Research exploring psychological dysfunction as a predictor of smoking cessation success may be limited by nonoptimal predictor variables (i.e., categorical psychodiagnostic measures vs. continuous personality-based manifestations of dysfunction) and imprecise outcomes (i.e., summative point prevalence abstinence vs. constituent cessation milestone measures). Accordingly, this study evaluated the unique and overlapping relations of broad-spectrum personality traits (positive emotionality, negative emotionality, and constraint) and past-year psychopathology (anxiety, mood, and substance use disorder) to point prevalence abstinence and three smoking cessation milestones: (1) initiating abstinence; (2) first lapse; and (3) transition from lapse to relapse. Participants were daily smokers (N=1365) enrolled in a smoking cessation treatment study. In single predictor regression models, each manifestation of internalizing dysfunction (lower positive emotionality, higher negative emotionality, and anxiety and mood disorder) predicted failure at one or more cessation milestone. In simultaneous predictor models, lower positive and higher negative emotionality significantly predicted failure to achieve milestones after controlling for psychopathology. Psychopathology did not predict any outcome when controlling for personality. Negative emotionality showed the most robust and consistent effects, significantly predicting failure to initiate abstinence, earlier lapse, and lower point prevalence abstinence rates. Substance use disorder and constraint did not predict cessation outcomes, and no single variable predicted lapse-to-relapse transition. These findings suggest that personality-related manifestations of internalizing dysfunction are more accurate markers of affective sources of relapse risk than mood and anxiety disorders. Further, individuals with high trait negative emotionality may require intensive intervention to promote the initiation and early maintenance of abstinence. PMID:22642858
Work-hardening behaviour of Mg single crystals oriented for basal slip
NASA Astrophysics Data System (ADS)
Bhattacharya, B.; Niewczas, M.
2011-06-01
Work-hardening behaviour of Mg single crystals oriented for basal slip was studied by means of tensile tests carried out at 4, 78 and 295 K. The crystals show critical resolved shear stress values (CRSS) for a {0001} ? basal slip system in the range 1-1.5 MPa. The samples exhibit two-stage work hardening characteristics consisting of a long easy glide stage and a stage of rapid hardening terminated by failure. The onset of the plastic flow up to the point of fracture is accompanied by a low work-hardening rate in the range 5 × 10-5-5 × 10-4 µ, corresponding to the hardening rate in Stage I of copper single crystals. The analysis of thermally activated glide parameters suggests that forest interactions are rate-controlling processes. The very low value of the activation distance found at 4 K, ∼0.047 b, is attributed to zero-point energy effects. The failure of crystals occurs well before their hardening capacity is exhausted by mechanisms which are characteristic of deformation temperature.
Scanning fluorescent microthermal imaging apparatus and method
Barton, Daniel L.; Tangyunyong, Paiboon
1998-01-01
A scanning fluorescent microthermal imaging (FMI) apparatus and method is disclosed, useful for integrated circuit (IC) failure analysis, that uses a scanned and focused beam from a laser to excite a thin fluorescent film disposed over the surface of the IC. By collecting fluorescent radiation from the film, and performing point-by-point data collection with a single-point photodetector, a thermal map of the IC is formed to measure any localized heating associated with defects in the IC.
Hocquelet, A; Frulio, N; Gallo, G; Laurent, C; Papadopoulos, P; Salut, C; Denys, A; Trillaud, H
2018-06-01
To correlate point-shear wave elastography (SWE) with liver hypertrophy after right portal vein embolization (RPVE) and to determine its usefulness in predicting postoperative liver failure in patients undergoing partial liver resection. Point-SWE was performed the day before RPVE in 56 patients (41 men) with a median age of 66 years. The percentage (%) of future remnant liver (FRL) volume increase was defined as: %FRL post -%FRL pre %FRL pre ×100 and assessed on computed tomography performed 4 weeks after RPVE. Median (range) %FRL pre and %FRL post was respectively, 31.5% (12-48%) and 41% (23-61%) (P<0.001), with a median %FRL volume increase of 25.6% (-8; 123%). SWE correlated with %FRL volume increase (P=-0.510; P<0.001). SWV (P=0.003) and %FRL pre (P<0.001) were associated with %FRL volume increase at multivariate regression analysis. Forty-three patients (77%) were operated. Postoperative liver failure occurred in 14 patients (32.5%). Median SWE was different between the group with (1.68m/s) and without liver failure (1.07m/s) (P=0.018). The AUROC of SWE predicting liver failure was 0.724 with a best cut-off of 1.31m/s, corresponding to a sensitivity of 21%, specificity of 96%, positive predictive value 75% and negative predictive value of 72%. SWE was the single independent preoperative variable associated with liver failure. SWE assessed by point-SWE is a simple and useful tool to predict the FRL volume increase and postoperative liver failure in a population of patients with liver tumor. Copyright © 2018 Société française de radiologie. Published by Elsevier Masson SAS. All rights reserved.
NASA Astrophysics Data System (ADS)
Tuninetti, V.; Yuan, S.; Gilles, G.; Guzmán, C. F.; Habraken, A. M.; Duchêne, L.
2016-08-01
This paper presents different extensions of the classical GTN damage model implemented in a finite element code. The goal of this study is to assess these extensions for the numerical prediction of failure of a DC01 steel sheet during a single point incremental forming process, after a proper identification of the material parameters. It is shown that the prediction of failure appears too early compared to experimental results. Though, the use of the Thomason criterion permitted to delay the onset of coalescence and consequently the final failure.
Scanning fluorescent microthermal imaging apparatus and method
Barton, D.L.; Tangyunyong, P.
1998-01-06
A scanning fluorescent microthermal imaging (FMI) apparatus and method is disclosed, useful for integrated circuit (IC) failure analysis, that uses a scanned and focused beam from a laser to excite a thin fluorescent film disposed over the surface of the IC. By collecting fluorescent radiation from the film, and performing point-by-point data collection with a single-point photodetector, a thermal map of the IC is formed to measure any localized heating associated with defects in the IC. 1 fig.
NASA Astrophysics Data System (ADS)
Taylor, Gabriel James
The failure of electrical cables exposed to severe thermal fire conditions are a safety concern for operating commercial nuclear power plants (NPPs). The Nuclear Regulatory Commission (NRC) has promoted the use of risk-informed and performance-based methods for fire protection which resulted in a need to develop realistic methods to quantify the risk of fire to NPP safety. Recent electrical cable testing has been conducted to provide empirical data on the failure modes and likelihood of fire-induced damage. This thesis evaluated numerous aspects of the data. Circuit characteristics affecting fire-induced electrical cable failure modes have been evaluated. In addition, thermal failure temperatures corresponding to cable functional failures have been evaluated to develop realistic single point thermal failure thresholds and probability distributions for specific cable insulation types. Finally, the data was used to evaluate the prediction capabilities of a one-dimension conductive heat transfer model used to predict cable failure.
Combining System Safety and Reliability to Ensure NASA CoNNeCT's Success
NASA Technical Reports Server (NTRS)
Havenhill, Maria; Fernandez, Rene; Zampino, Edward
2012-01-01
Hazard Analysis, Failure Modes and Effects Analysis (FMEA), the Limited-Life Items List (LLIL), and the Single Point Failure (SPF) List were applied by System Safety and Reliability engineers on NASA's Communications, Navigation, and Networking reConfigurable Testbed (CoNNeCT) Project. The integrated approach involving cross reviews of these reports by System Safety, Reliability, and Design engineers resulted in the mitigation of all identified hazards. The outcome was that the system met all the safety requirements it was required to meet.
Model-OA wind turbine generator - Failure modes and effects analysis
NASA Technical Reports Server (NTRS)
Klein, William E.; Lali, Vincent R.
1990-01-01
The results failure modes and effects analysis (FMEA) conducted for wind-turbine generators are presented. The FMEA was performed for the functional modes of each system, subsystem, or component. The single-point failures were eliminated for most of the systems. The blade system was the only exception. The qualitative probability of a blade separating was estimated at level D-remote. Many changes were made to the hardware as a result of this analysis. The most significant change was the addition of the safety system. Operational experience and need to improve machine availability have resulted in subsequent changes to the various systems, which are also reflected in this FMEA.
NASA Technical Reports Server (NTRS)
Arakere, N. K.; Swanson, G.
2002-01-01
High cycle fatigue (HCF) induced failures in aircraft gas turbine and rocket engine turbopump blades is a pervasive problem. Single crystal nickel turbine blades are being utilized in rocket engine turbopumps and jet engines throughout industry because of their superior creep, stress rupture, melt resistance, and thermomechanical fatigue capabilities over polycrystalline alloys. Currently the most widely used single crystal turbine blade superalloys are PWA 1480/1493, PWA 1484, RENE' N-5 and CMSX-4. These alloys play an important role in commercial, military and space propulsion systems. Single crystal materials have highly orthotropic properties making the position of the crystal lattice relative to the part geometry a significant factor in the overall analysis. The failure modes of single crystal turbine blades are complicated to predict due to the material orthotropy and variations in crystal orientations. Fatigue life estimation of single crystal turbine blades represents an important aspect of durability assessment. It is therefore of practical interest to develop effective fatigue failure criteria for single crystal nickel alloys and to investigate the effects of variation of primary and secondary crystal orientation on fatigue life. A fatigue failure criterion based on the maximum shear stress amplitude /Delta(sub tau)(sub max))] on the 24 octahedral and 6 cube slip systems, is presented for single crystal nickel superalloys (FCC crystal). This criterion reduces the scatter in uniaxial LCF test data considerably for PWA 1493 at 1200 F in air. Additionally, single crystal turbine blades used in the alternate advanced high-pressure fuel turbopump (AHPFTP/AT) are modeled using a large-scale three-dimensional finite element model. This finite element model is capable of accounting for material orthotrophy and variation in primary and secondary crystal orientation. Effects of variation in crystal orientation on blade stress response are studied based on 297 finite element model runs. Fatigue lives at critical points in the blade are computed using finite element stress results and the failure criterion developed. Stress analysis results in the blade attachment region are also presented. Results presented demonstrates that control of secondary and primary crystallographic orientation has the potential to significantly increase a component S resistance to fatigue crack growth with- out adding additional weight or cost. [DOI: 10.1115/1.1413767
A tri-reference point theory of decision making under risk.
Wang, X T; Johnson, Joseph G
2012-11-01
The tri-reference point (TRP) theory takes into account minimum requirements (MR), the status quo (SQ), and goals (G) in decision making under risk. The 3 reference points demarcate risky outcomes and risk perception into 4 functional regions: success (expected value of x ≥ G), gain (SQ < × < G), loss (MR ≤ x < SQ), and failure (x < MR). The psychological impact of achieving or failing to achieve these reference points is rank ordered as MR > G > SQ. We present TRP assumptions and value functions and a mathematical formalization of the theory. We conducted empirical tests of crucial TRP predictions using both explicit and implicit reference points. We show that decision makers consider both G and MR and give greater weight to MR than G, indicating failure aversion (i.e., the disutility of a failure is greater than the utility of a success in the same task) in addition to loss aversion (i.e., the disutility of a loss is greater than the utility of the same amount of gain). Captured by a double-S shaped value function with 3 inflection points, risk preferences switched between risk seeking and risk aversion when the distribution of a gamble straddled a different reference point. The existence of MR (not G) significantly shifted choice preference toward risk aversion even when the outcome distribution of a gamble was well above the MR. Single reference point based models such as prospect theory cannot consistently account for these findings. The TRP theory provides simple guidelines for evaluating risky choices for individuals and organizational management. (PsycINFO Database Record (c) 2012 APA, all rights reserved).
76 FR 64082 - Mandatory Reliability Standards for the Bulk-Power System; Notice of Staff Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-17
... Reliability Standards for the Bulk-Power System; Notice of Staff Meeting Take notice that the Federal Energy... reliability implications to the interconnected transmission system associated with a single point of failure... R1.3.10 of Commission-approved transmission planning Reliability Standard TPL-002- 0 (System...
Baums, Mike H; Spahn, Gunter; Buchhorn, Gottfried H; Schultz, Wolfgang; Hofmann, Lars; Klinger, Hans-Michael
2012-06-01
To investigate the biomechanical and magnetic resonance imaging (MRI)-derived morphologic changes between single- and double-row rotator cuff repair at different time points after fixation. Eighteen mature female sheep were randomly assigned to either a single-row treatment group using arthroscopic Mason-Allen stitches or a double-row treatment group using a combination of arthroscopic Mason-Allen and mattress stitches. Each group was analyzed at 1 of 3 survival points (6 weeks, 12 weeks, and 26 weeks). We evaluated the integrity of the cuff repair using MRI and biomechanical properties using a mechanical testing machine. The mean load to failure was significantly higher in the double-row group compared with the single-row group at 6 and 12 weeks (P = .018 and P = .002, respectively). At 26 weeks, the differences were not statistically significant (P = .080). However, the double-row group achieved a mean load to failure similar to that of a healthy infraspinatus tendon, whereas the single-row group reached only 70% of the load of a healthy infraspinatus tendon. No significant morphologic differences were observed based on the MRI results. This study confirms that in an acute repair model, double-row repair may enhance the speed of mechanical recovery of the tendon-bone complex when compared with single-row repair in the early postoperative period. Double-row rotator cuff repair enables higher mechanical strength that is especially sustained during the early recovery period and may therefore improve clinical outcome. Crown Copyright © 2012. Published by Elsevier Inc. All rights reserved.
Managing Risk to Ensure a Successful Cassini/Huygens Saturn Orbit Insertion (SOI)
NASA Technical Reports Server (NTRS)
Witkowski, Mona M.; Huh, Shin M.; Burt, John B.; Webster, Julie L.
2004-01-01
I. Design: a) S/C designed to be largely single fault tolerant; b) Operate in flight demonstrated envelope, with margin; and c) Strict compliance with requirements & flight rules. II. Test: a) Baseline, fault & stress testing using flight system testbeds (H/W & S/W); b) In-flight checkout & demos to remove first time events. III. Failure Analysis: a) Critical event driven fault tree analysis; b) Risk mitigation & development of contingencies. IV) Residual Risks: a) Accepted pre-launch waivers to Single Point Failures; b) Unavoidable risks (e.g. natural disaster). V) Mission Assurance: a) Strict process for characterization of variances (ISAs, PFRs & Waivers; b) Full time Mission Assurance Manager reports to Program Manager: 1) Independent assessment of compliance with institutional standards; 2) Oversight & risk assessment of ISAs, PFRs & Waivers etc.; and 3) Risk Management Process facilitator.
Biomechanical evaluation of a single-row versus double-row repair for complete subscapularis tears.
Wellmann, Mathias; Wiebringhaus, Philipp; Lodde, Ina; Waizy, Hazibullah; Becher, Christoph; Raschke, Michael J; Petersen, Wolf
2009-12-01
The purpose of the study was to compare a single-row repair and a double-row repair technique for the specific characteristics of a complete subscapularis lesion. Ten pairs of human cadaveric shoulder human shoulder specimens were tested for stiffness and ultimate tensile strength of the intact tendons in a load to failure protocol. After a complete subscapularis tear was provoked, the specimens were assigned to two treatment groups: single-row repair (1) and a double-row repair using a "suture bridge" technique (2). After repair cyclic loading a subsequent load to failure protocol was performed to determine the ultimate tensile load, the stiffness and the elongation behaviour of the reconstructions. The intact subscapularis tendons had a mean stiffness of 115 N/mm and a mean ultimate load of 720 N. The predominant failure mode of the intact tendons was a tear at the humeral insertion site (65%). The double-row technique restored 48% of the ultimate load of the intact tendons (332 N), while the single-row technique revealed a significantly lower ultimate load of 244 N (P = 0.001). In terms of the stiffness, the double-row technique showed a mean stiffness of 81 N/mm which is significantly higher compared to the stiffness of the single-row repairs of 55 N/mm (P = 0.001). The double-row technique has been shown to be stronger and stiffer when compared to a conventional single-row repair. Therefore, this technique is recommended from a biomechanical point of view irrespectively if performed by an open or arthroscopic approach.
Revision total knee arthroplasty for septic versus aseptic failure.
Rajgopal, Ashok; Vasdev, Attique; Gupta, Himanshu; Dahiya, Vivek
2013-12-01
To compare the medium-term outcome of revision total knee arthroplasty (TKA) for septic versus aseptic failure. Records of 142 patients who underwent revision TKA by a single senior surgeon for septic (n=65) or aseptic (n=77) failure were reviewed. In the septic group, 67 knees in 42 women and 23 men were included. In the aseptic group, 88 knees in 51 women and 26 men were included. The Knee Society Score was measured. The Kaplan Meier survival curve at months 36, 60, and 95 was plotted, with revision as the end point. The survival rates at each specific time point between the 2 groups were compared using the Z test. The Knee Society Scores improved 18% from 51 to 69 in the septic group and 18% from 52 to 70 in the aseptic group (p=0.72). The range of motion improved 30% from 72 to 102 degrees in the septic group and 39% from 62 to 100 degrees in the aseptic group (p<0.001). Results of the 2 groups were similar in terms of the Knee Society Score, range of motion, and the Kaplan-Meier survivorship.
Basílio, Mariana de Almeida; Delben, Juliana Aparecida; Cesar, Paulo Francisco; Rizkalla, Amin Sami; Santos Junior, Gildo Coelho; Arioli Filho, João Neudenir
2016-07-01
Yttria-stabilized tetragonal zirconia (Y-TZP) was introduced as ceramic implant abutments due to its excellent mechanical properties. However, the damage patterns for Y-TZP abutments are limited in the literature. Fractographic analyses can provide insights as to the failure origin and related mechanisms. The purpose of this study was to analyze fractured Y-TZP abutments to establish fractographic patterns and then possible reasons for failure. Thirty two prefabricated Y-TZP abutments on external hex implants were retrieved from a single-load-to failure test according to the ISO 14801. Fractographic analyses were conducted under polarized-light estereo and scanning electro microscopy. The predominant fracture pattern was abutment fracture at the connecting region. Classic fractographic features such as arrest lines, hackle, and twist hackle established that failure started where Y-TZP abutments were in contact with the retention screw edges. The abutment screw design and the loading point were the reasons for localized stress concentration and fracture patterns. Copyright © 2016 Elsevier Ltd. All rights reserved.
Distributed Evaluation Functions for Fault Tolerant Multi-Rover Systems
NASA Technical Reports Server (NTRS)
Agogino, Adrian; Turner, Kagan
2005-01-01
The ability to evolve fault tolerant control strategies for large collections of agents is critical to the successful application of evolutionary strategies to domains where failures are common. Furthermore, while evolutionary algorithms have been highly successful in discovering single-agent control strategies, extending such algorithms to multiagent domains has proven to be difficult. In this paper we present a method for shaping evaluation functions for agents that provide control strategies that both are tolerant to different types of failures and lead to coordinated behavior in a multi-agent setting. This method neither relies of a centralized strategy (susceptible to single point of failures) nor a distributed strategy where each agent uses a system wide evaluation function (severe credit assignment problem). In a multi-rover problem, we show that agents using our agent-specific evaluation perform up to 500% better than agents using the system evaluation. In addition we show that agents are still able to maintain a high level of performance when up to 60% of the agents fail due to actuator, communication or controller faults.
The impact of age and gender on cardiac resynchronization therapy outcome.
Zardkoohi, Omeed; Nandigam, Veena; Murray, Lorne; Heist, E Kevin; Mela, Theofanie; Orencole, Mary; Ruskin, Jeremy N; Singh, Jagmeet P
2007-11-01
Cardiac resynchronization therapy (CRT) outcome varies significantly among patients. We aimed to determine the impact of age, gender, and heart failure etiology on the long-term outcome of patients receiving CRT. A total of 117 patients with drug-refractory heart failure, New York Heart Association (NYHA) Class III or IV, and a wide QRS complex, who received CRT, were followed for one year. Long-term outcome was measured as a combined end point of hospitalization for heart failure and/or all cause mortality. Efficacy of CRT was compared between men and women, between older and younger patients, and between patients with ischemic and nonischemic heart disease. Time to the primary end point was estimated by the Kaplan-Meier method and comparisons were made using the Breslow-Wilcoxon test. Baseline clinical characteristics were comparable between gender, age, and heart failure etiology subgroups. There was no significant difference in the combined end point between older versus younger (age >70, (n = 71), versus age < 70, (n = 46), P = 0.52); both genders (men, n = 91 vs women, n = 26, P = 0.46) and etiology of the cardiomyopathy (ischemic (n = 79) vs nonischemic (n = 38), P = 0.12). Substratification of the genders by the etiology of the cardiomyopathy, showed that women with ischemic cardiomyopathy (IW, n = 10) had a trend to a worse outcome compared to the other groups i.e., nonischemic women (NIW, n = 16), ischemic men (IM, n = 69), and nonischemic men (NIM, n = 22), P = 0.04. After adjusting for potential covariates, a Cox regression analysis showed no significant difference between the groups (P = 0.61). CRT outcome appears independent of age, gender, and heart failure etiology in this single institution study.
Exploring the temperature dependence of failure mechanisms in fragmenting metal cylinders
NASA Astrophysics Data System (ADS)
Jones, David; Chapman, David; Hazell, Paul; Bland, Simon; Eakins, Daniel
2011-06-01
We present current work to investigate the influence of temperature on the dynamic fragmentation of metals. Pre-heated/cooled cylinders of Ti-6Al-4V were subjected to rapid radial expansion up to and past the point of failure using a modified expanding insert method on a single stage gas gun. Additional experiments were performed using an electromagnetic drive system to produce uniform deformations on targets of differing dimensions (radius, wall thickness). Issues concerning the geometry of the experiments, methods of heating and cooling the sample and diagnostics are covered. Finally, the role of temperature on adiabatic shear banding and fragment distribution statistics is discussed.
Model 0A wind turbine generator FMEA
NASA Technical Reports Server (NTRS)
Klein, William E.; Lalli, Vincent R.
1989-01-01
The results of Failure Modes and Effects Analysis (FMEA) conducted for the Wind Turbine Generators are presented. The FMEA was performed for the functional modes of each system, subsystem, or component. The single-point failures were eliminated for most of the systems. The blade system was the only exception. The qualitative probability of a blade separating was estimated at level D-remote. Many changes were made to the hardware as a result of this analysis. The most significant change was the addition of the safety system. Operational experience and need to improve machine availability have resulted in subsequent changes to the various systems which are also reflected in this FMEA.
Chen, Rui; Wang, Haotian; Shi, Jun; Hu, Pei
2016-05-01
CYP2D6 is a high polymorphic enzyme. Determining its phenotype before CYP2D6 substrate treatment can avoid dose-dependent adverse events or therapeutic failures. Alternative phenotyping methods of CYP2D6 were compared to aluate the appropriate and precise time points for phenotyping after single-dose and ultiple-dose of 30-mg controlled-release (CR) dextromethorphan (DM) and to explore the antimodes for potential sampling methods. This was an open-label, single and multiple-dose study. 21 subjects were assigned to receive a single dose of CR DM 30 mg orally, followed by a 3-day washout period prior to oral administration of CR DM 30 mg every 12 hours for 6 days. Metabolic ratios (MRs) from AUC∞ after single dosing and from AUC0-12h at steady state were taken as the gold standard. The correlations of metabolic ratios of DM to dextrorphan (MRDM/DX) values based on different phenotyping methods were assessed. Linear regression formulas were derived to calculate the antimodes for potential sample methods. In the single-dose part of the study statistically significant correlations were found between MRDM/DX from AUC∞ and from serial plasma points from 1 to 30 hours or from urine (all p-values < 0.001). In the multiple-dose part, statistically significant correlations were found between MRDM/DX from AUC0-12h on day 6 and MRDM/DX from serial plasma points from 0 to 36 hours after the last dosing (all p-values < 0.001). Based on reported urinary antimode and linear regression analysis, the antimodes of AUC and plasma points were derived to profile the trend of antimodes as the drug concentrations changed. MRDM/DX from plasma points had good correlations with MRDM/DX from AUC. Plasma points from 1 to 30 hours after single dose of 30-mg CR DM and any plasma point at steady state after multiple doses of CR DM could potentially be used for phenotyping of CYP2D6.
Joint Force Interdependence for a Fiscally Constrained Future
2013-03-01
avoid single points of failure during operations. DoD leaders must immediately capitalize on their fiscal constraints to create opportunities for...political and organizational obstacles to achieving a sound fiscal defense policy will require a profound effort by strategic leaders to embed and... leaders . This paper will assess recent strategic guidance and concepts for intent and meaning while focusing on key terms used by leaders in these
Lin, Wen-Yen; Chou, Wen-Cheng; Chang, Po-Cheng; Chou, Chung-Chuan; Wen, Ming-Shien; Ho, Ming-Yun; Lee, Wen-Chen; Hsieh, Ming-Jer; Lin, Chung-Chih; Tsai, Tsai-Hsuan; Lee, Ming-Yih
2018-03-01
Seismocardiogram (SCG) or mechanocardiography is a noninvasive cardiac diagnostic method; however, previous studies used only a single sensor to detect cardiac mechanical activities that will not be able to identify location-specific feature points in a cardiac cycle corresponding to the four valvular auscultation locations. In this study, a multichannel SCG spectrum measurement system was proposed and examined for cardiac activity monitoring to overcome problems like, position dependency, time delay, and signal attenuation, occurring in traditional single-channel SCG systems. ECG and multichannel SCG signals were simultaneously recorded in 25 healthy subjects. Cardiac echocardiography was conducted at the same time. SCG traces were analyzed and compared with echocardiographic images for feature point identification. Fifteen feature points were identified in the corresponding SCG traces. Among them, six feature points, including left ventricular lateral wall contraction peak velocity, septal wall contraction peak velocity, transaortic peak flow, transpulmonary peak flow, transmitral ventricular relaxation flow, and transmitral atrial contraction flow were identified. These new feature points were not observed in previous studies because the single-channel SCG could not detect the location-specific signals from other locations due to time delay and signal attenuation. As the results, the multichannel SCG spectrum measurement system can record the corresponding cardiac mechanical activities with location-specific SCG signals and six new feature points were identified with the system. This new modality may help clinical diagnoses of valvular heart diseases and heart failure in the future.
Bartlett, Ashley; Wales, Larry; Houfburg, Rodney; Durfee, William K; Griffith, Steven L; Bentley, Ishmael
2013-10-01
In vitro comparative, laboratory experiments. This study developed a laboratory apparatus that measured resistance to failure using pressures similar to intradiscal pressure of a lumbar spinal disk. Various combinations of an anular repair device were compared. Herniated material of the intervertebral disk is removed during a lumbar discectomy; however, the defect in the anulus fibrosus remains and can provide a pathway for future herniation. Repairing the anulus fibrosus could mitigate this reherniation and improve patient outcomes. A pneumatic cylinder was used to increase the pressure of a sealed chamber until artificial nucleus pulposus material was expulsed through either a 3-mm circular (diameter) or a 6-mm slit anular defect created in a surrogate anulus fibrosus. Each unrepaired condition was compared with 3 repaired conditions using a commercially available soft tissue repair system. The repaired conditions included: (1) a single tension band; (2) 2 tension bands in a cruciate pattern; or (3) 2 tension bands in a parallel pattern. Maximum pressure at the point of extrusion of the internal chamber material and failure or nonfailure of the repair was measured. Significant differences were detected (P<0.05) in maximum failure pressures for the nonrepaired (control) versus repaired conditions. With 1 or 2 tension bands repairing the circular defect, the maximum failure pressure increased by approximately 76% and 131%, respectively. In addition, the failure pressure for 2 tension bands in either a cruciate or parallel configuration was not different, and was approximately 32% higher (P<0.05) than a single tension band in the case of the circular defect. Similar results were seen for the slit defect, with the exception that no difference between the repaired conditions (ie, single vs. 2 tension bands) was detected. This laboratory simulation demonstrated that repairing the anulus fibrosus after a discectomy procedure can be beneficial for retaining intradiscal material. The use of 2 tension bands, versus a single tension band, in either a cruciate or parallel configuration may further improve the ability to retain disk material.
Penn, Marc S; Mendelsohn, Farrell O; Schaer, Gary L; Sherman, Warren; Farr, Maryjane; Pastore, Joseph; Rouy, Didier; Clemens, Ruth; Aras, Rahul; Losordo, Douglas W
2013-03-01
Preclinical studies indicate that adult stem cells induce tissue repair by activating endogenous stem cells through the stromal cell-derived factor-1:chemokine receptor type 4 axis. JVS-100 is a DNA plasmid encoding human stromal cell-derived factor-1. We tested in a phase 1, open-label, dose-escalation study with 12 months of follow-up in subjects with ischemic cardiomyopathy to see if JVS-100 improves clinical parameters. Seventeen subjects with ischemic cardiomyopathy, New York Heart Association class III heart failure, with an ejection fraction ≤40% on stable medical therapy, were enrolled to receive 5, 15, or 30 mg of JVS-100 via endomyocardial injection. The primary end points for safety and efficacy were at 1 and 4 months, respectively. The primary safety end point was a major adverse cardiac event. Efficacy end points were change in quality of life, New York Heart Association class, 6-minute walk distance, single photon emission computed tomography, N-terminal pro-brain natruretic peptide, and echocardiography at 4 and 12 months. The primary safety end point was met. At 4 months, all of the cohorts demonstrated improvements in 6-minute walk distance, quality of life, and New York Heart Association class. Subjects in the 15- and 30-mg dose groups exhibited improvements in 6-minute walk distance (15 mg: median [range]: 41 minutes [3-61 minutes]; 30 mg: 31 minutes [22-74 minutes]) and quality of life (15 mg: -16 points [+1 to -32 points]; 30 mg: -24 points [+17 to -38 points]) over baseline. At 12 months, improvements in symptoms were maintained. These data highlight the importance of defining the molecular mechanisms of stem cell-based tissue repair and suggest that overexpression of stromal cell-derived factor-1 via gene therapy is a strategy for improving heart failure symptoms in patients with ischemic cardiomyopathy.
Fu, Yijun; Xie, Qixue; Lao, Jihong; Wang, Lu
2016-01-01
Fiber shedding is a critical problem in biomedical textile debridement materials, which leads to infection and impairs wound healing. In this work, single fiber pull-out test was proposed as an in vitro evaluation for the fiber shedding property of a textile pile debridement material. Samples with different structural design (pile densities, numbers of ground yarns and coating times) were prepared and estimated under this testing method. Results show that single fiber pull-out test offers an appropriate in vitro evaluation for the fiber shedding property of textile pile debridement materials. Pull-out force for samples without back-coating exhibited a slight escalating trend with the supplement in pile density and number of ground yarn plies, while back-coating process significantly raised the single fiber pull-out force. For fiber shedding mechanism analysis, typical pull-out behavior and failure modes of the single fiber pull-out test were analyzed in detail. Three failure modes were found in this study, i.e., fiber slippage, coating point rupture and fiber breakage. In summary, to obtain samples with desirable fiber shedding property, fabric structural design, preparation process and raw materials selection should be taken into full consideration. PMID:28773428
NASA Technical Reports Server (NTRS)
Bailey, Randall E.; Kramer, Lynda J.; Kennedy, Kellie D.; Stephens, Chad L.; Etherington, Timothy J.
2017-01-01
Future reduced crew operations or even single pilot operations for commercial airline and on-demand mobility applications are an active area of research. These changes would reduce the human element and thus, threaten the precept that "a well-trained and well-qualified pilot is the critical center point of aircraft systems safety and an integral safety component of the entire commercial aviation system." NASA recently completed a pilot-in-the-loop high fidelity motion simulation study in partnership with the Federal Aviation Administration (FAA) attempting to quantify the pilot's contribution to flight safety during normal flight and in response to aircraft system failures. Crew complement was used as the experiment independent variable in a between-subjects design. These data show significant increases in workload for single pilot operations, compared to two-crew, with subjective assessments of safety and performance being significantly degraded as well. Nonetheless, in all cases, the pilots were able to overcome the failure mode effects in all crew configurations. These data reflect current-day flight deck equipage and help identify the technologies that may improve two-crew operations and/or possibly enable future reduced crew and/or single pilot operations.
Natera, Luis; Consigliere, Paolo; Witney-Lagen, Caroline; Brugera, Juan; Sforza, Giuseppe; Atoun, Ehud; Levy, Ofer
2017-10-01
Many techniques of arthroscopic rotator cuff repair have been described. No significant differences in clinical outcomes or rerupture rates have been observed when comparing single-row with double-row methods. Not all single- and double-row repairs are the same. The details of the technique used are crucial. It has been shown that the suture-tendon interface is the weakest point of the reconstruction. Therefore, the biomechanical properties of rotator cuff repairs might be influenced more by the suture configuration than by the number of anchors or by the number of rows involved. Techniques that secure less amount of tendon over a smaller area of the healing zone might be expected to have higher failure rates. The way the sutures of the "parachute technique" are configured represents a quadruple mattress that increases the contact and pressure between the tendon and its footprint and increases the primary load to failure of the repair. We present a simple and effective single-row technique that involves the biomechanical and biological advantages related to the increased contact area and pressure between the cuff and its footprint.
Assessment of Multiaxial Mechanical Response of Rigid Polyurethane Foams
NASA Astrophysics Data System (ADS)
Pettarin, Valeria; Fasce, Laura A.; Frontini, Patricia M.
2014-02-01
Multiaxial deformation behavior and failure surface of rigid polyurethane foams were determined using standard experimental facilities. Two commercial foams of different densities were assayed under uniaxial, biaxial, and triaxial stress states. These different stress states were reached in a uniaxial universal testing machine using suitable testing configurations which imply the use of special grips and lateral restricted samples. Actual strains were monitored with a video extensometer. Polyurethane foams exhibited typical isotropic brittle behavior, except under compressive loads where the response turned out to be ductile. A general failure surface in the stress space which accounts for density effects could be successfully generated. All of failure data, determined at the loss of linear elasticity point, collapsed in a single locus defined as the combination of a brittle crushing of closed-cell cellular materials criterion capped by an elastic buckling criterion.
Fast grasping of unknown objects using cylinder searching on a single point cloud
NASA Astrophysics Data System (ADS)
Lei, Qujiang; Wisse, Martijn
2017-03-01
Grasping of unknown objects with neither appearance data nor object models given in advance is very important for robots that work in an unfamiliar environment. The goal of this paper is to quickly synthesize an executable grasp for one unknown object by using cylinder searching on a single point cloud. Specifically, a 3D camera is first used to obtain a partial point cloud of the target unknown object. An original method is then employed to do post treatment on the partial point cloud to minimize the uncertainty which may lead to grasp failure. In order to accelerate the grasp searching, surface normal of the target object is then used to constrain the synthetization of the cylinder grasp candidates. Operability analysis is then used to select out all executable grasp candidates followed by force balance optimization to choose the most reliable grasp as the final grasp execution. In order to verify the effectiveness of our algorithm, Simulations on a Universal Robot arm UR5 and an under-actuated Lacquey Fetch gripper are used to examine the performance of this algorithm, and successful results are obtained.
Annular suspension and pointing system with controlled DC electromagnets
NASA Technical Reports Server (NTRS)
Vu, Josephine Lynn; Tam, Kwok Hung
1993-01-01
The Annular Suspension and Pointing System (ASPS) developed by the Flight System division of Sperry Corporation is a six-degree of freedom payload pointing system designed for use with the space shuttle. This magnetic suspension and pointing system provides precise controlled pointing in six-degrees of freedom, isolation of payload-carrier disturbances, and end mount controlled pointing. Those are great advantages over the traditional mechanical joints for space applications. In this design, we first analyzed the assumed model of the single degree ASPS bearing actuator and obtained the plant dynamics equations. By linearizing the plant dynamics equations, we designed the cascade and feedback compensators such that a stable and satisfied result was obtained. The specified feedback compensator was computer simulated with the nonlinearized plant dynamics equations. The results indicated that an unstable output occurred. In other words, the designed feedback compensator failed. The failure of the design is due to the Taylor's series expansion not converging.
Single point incremental forming: Formability of PC sheets
NASA Astrophysics Data System (ADS)
Formisano, A.; Boccarusso, L.; Carrino, L.; Lambiase, F.; Minutolo, F. Memola Capece
2018-05-01
Recent research on Single Point Incremental Forming of polymers has slightly covered the possibility of expanding the materials capability window of this flexible forming process beyond metals, by demonstrating the workability of thermoplastic polymers at room temperature. Given the different behaviour of polymers compared to metals, different aspects need to be deepened to better understand the behaviour of these materials when incrementally formed. Thus, the aim of the work is to investigate the formability of incrementally formed polycarbonate thin sheets. To this end, an experimental investigation at room temperature was conducted involving formability tests; varying wall angle cone and pyramid frusta were manufactured by processing polycarbonate sheets with different thicknesses and using tools with different diameters, in order to draw conclusions on the formability of polymer sheets through the evaluation of the forming angles and the observation of the failure mechanisms.
Application of Improved Genetic Algorithm to Service Restoration Problem for Distribution Systems
NASA Astrophysics Data System (ADS)
Michibata, Ikuo; Aoki, Hidenori
The problem of recovery from power-system failures is the problem of handling operations that make it possible to supply power from other lines in response to power-system failures or construction by switching between the opened and closed states of sectionalizing switches. Considerable research has already been conducted with regard to this issue. This paper addresses the issue of determining target systems for final recovery in cases when some sections remain subject to power failure (i.e., sound bank capacity < load capacity). For this purpose, intersection is conducted only for parameters within such power-failure sections. In such research, calculations are implemented by setting a value of 2 to the sectionalizing switches of a single parameter. In addition, when the state of a sound section changes due to mutation improvements, the method of simultaneously changing the selected points and neighboring sectionalizing switches is applied. It is clear that the proposed method, consisting of conventional GA only, is superior in terms of average fitness values.
Data-Driven Packet Loss Estimation for Node Healthy Sensing in Decentralized Cluster.
Fan, Hangyu; Wang, Huandong; Li, Yong
2018-01-23
Decentralized clustering of modern information technology is widely adopted in various fields these years. One of the main reason is the features of high availability and the failure-tolerance which can prevent the entire system form broking down by a failure of a single point. Recently, toolkits such as Akka are used by the public commonly to easily build such kind of cluster. However, clusters of such kind that use Gossip as their membership managing protocol and use link failure detecting mechanism to detect link failures cannot deal with the scenario that a node stochastically drops packets and corrupts the member status of the cluster. In this paper, we formulate the problem to be evaluating the link quality and finding a max clique (NP-Complete) in the connectivity graph. We then proposed an algorithm that consists of two models driven by data from application layer to respectively solving these two problems. Through simulations with statistical data and a real-world product, we demonstrate that our algorithm has a good performance.
Gross, Thomas P; Liu, Fei; Webb, Lee A
2012-04-01
This report extends the follow-up for the largest center of the first multicenter US Food and Drug Administration investigational device exemption study on metal-on-metal hip resurfacing arthroplasty up to 11 years. A single surgeon performed 373 hip resurfacing arthroplasties using the hybrid Corin Cormet 2000 system. The Kaplan-Meier survivorship at 11 years was 93% when revision for any reason was used as an end point and 91% if radiographic failures were included. The clinical results demonstrate an acceptable failure rate with use of this system. Loosening of the cemented femoral components was the most common source of failure and occurred at all follow-up intervals. A learning curve that persisted for at least 200 cases was confirmed. All femoral neck fractures occurred before 6 months postoperatively. Copyright © 2012 Elsevier Inc. All rights reserved.
Volcanic Eruption Forecasts From Accelerating Rates of Drumbeat Long-Period Earthquakes
NASA Astrophysics Data System (ADS)
Bell, Andrew F.; Naylor, Mark; Hernandez, Stephen; Main, Ian G.; Gaunt, H. Elizabeth; Mothes, Patricia; Ruiz, Mario
2018-02-01
Accelerating rates of quasiperiodic "drumbeat" long-period earthquakes (LPs) are commonly reported before eruptions at andesite and dacite volcanoes, and promise insights into the nature of fundamental preeruptive processes and improved eruption forecasts. Here we apply a new Bayesian Markov chain Monte Carlo gamma point process methodology to investigate an exceptionally well-developed sequence of drumbeat LPs preceding a recent large vulcanian explosion at Tungurahua volcano, Ecuador. For more than 24 hr, LP rates increased according to the inverse power law trend predicted by material failure theory, and with a retrospectively forecast failure time that agrees with the eruption onset within error. LPs resulted from repeated activation of a single characteristic source driven by accelerating loading, rather than a distributed failure process, showing that similar precursory trends can emerge from quite different underlying physics. Nevertheless, such sequences have clear potential for improving forecasts of eruptions at Tungurahua and analogous volcanoes.
Fibrosis-Related Gene Expression in Single Ventricle Heart Disease.
Nakano, Stephanie J; Siomos, Austine K; Garcia, Anastacia M; Nguyen, Hieu; SooHoo, Megan; Galambos, Csaba; Nunley, Karin; Stauffer, Brian L; Sucharov, Carmen C; Miyamoto, Shelley D
2017-12-01
To evaluate fibrosis and fibrosis-related gene expression in the myocardium of pediatric subjects with single ventricle with right ventricular failure. Real-time quantitative polymerase chain reaction was performed on explanted right ventricular myocardium of pediatric subjects with single ventricle disease and controls with nonfailing heart disease. Subjects were divided into 3 groups: single ventricle failing (right ventricular failure before or after stage I palliation), single ventricle nonfailing (infants listed for primary transplantation with normal right ventricular function), and stage III (Fontan or right ventricular failure after stage III). To evaluate subjects of similar age and right ventricular volume loading, single ventricle disease with failure was compared with single ventricle without failure and stage III was compared with nonfailing right ventricular disease. Histologic fibrosis was assessed in all hearts. Mann-Whitney tests were performed to identify differences in gene expression. Collagen (Col1α, Col3) expression is decreased in single ventricle congenital heart disease with failure compared with nonfailing single ventricle congenital heart disease (P = .019 and P = .035, respectively), and is equivalent in stage III compared with nonfailing right ventricular heart disease. Tissue inhibitors of metalloproteinase (TIMP-1, TIMP-3, and TIMP-4) are downregulated in stage III compared with nonfailing right ventricular heart disease (P = .0047, P = .013 and P = .013, respectively). Matrix metalloproteinases (MMP-2, MMP-9) are similar between nonfailing single ventricular heart disease and failing single ventricular heart disease, and between stage III heart disease and nonfailing right ventricular heart disease. There is no difference in the prevalence of right ventricular fibrosis by histology in subjects with single ventricular failure heart disease with right ventricular failure (18%) compared with those with normal right ventricular function (38%). Fibrosis is not a primary contributor to right ventricular failure in infants and young children with single ventricular heart disease. Additional studies are required to understand whether antifibrotic therapies are beneficial in this population. Copyright © 2017 Elsevier Inc. All rights reserved.
Triggering Mechanism for Neutron Induced Single-Event Burnout in Power Devices
NASA Astrophysics Data System (ADS)
Shoji, Tomoyuki; Nishida, Shuichi; Hamada, Kimimori
2013-04-01
Cosmic ray neutrons can trigger catastrophic failures in power devices. It has been reported that parasitic transistor action causes single-event burnout (SEB) in power metal-oxide-semiconductor field-effect transistors (MOSFETs) and insulated gate bipolar transistors (IGBTs). However, power diodes do not have an inherent parasitic transistor. In this paper, we describe the mechanism triggering SEB in power diodes for the first time using transient device simulation. Initially, generated electron-hole pairs created by incident recoil ions generate transient current, which increases the electron density in the vicinity of the n-/n+ boundary. The space charge effect of the carriers leads to an increase in the strength of the electric field at the n-/n+ boundary. Finally, the onset of impact ionization at the n-/n+ boundary can trigger SEB. Furthermore, this failure is closely related to diode secondary breakdown. It was clarified that the impact ionization at the n-/n+ boundary is a key point of the mechanism triggering SEB in power devices.
NASA Technical Reports Server (NTRS)
Binienda, Wieslaw K.; Roberts, Gary D.; Papadopoulos, Demetrios S.
1992-01-01
The results of in-plane four-point bend experiments on unidirectionally reinforced composite beams are presented for graphite/epoxy (T300/934) and graphite/polyimide (G30-500/PMR-15) composites. The maximum load and the location of cracks formed during failure were measured for testpieces with fibers oriented at various angles to the beam axis. Since most of the beams failed near one or more of the load points, the strength of the beams was evaluated in terms of a proposed model, for the local stress distribution. In this model, an exact solution to the problem of a localized contact force acting on a unidirectionally reinforced half plane is used to describe the local stress field. The stress singularity at the load points is treated in a manner similar to the stress singularity at a crack tip in fracture mechanisms problems. Using this approach, the effect of fiber angle and elastic material properties on the strength of the beam is described in terms of a load intensity factor. For fiber angles less than 45 deg from the beam axis, a single crack is initiated near one of the load points at a critical value of the load intensity factor. The critical load intensity factor decreases with the increasing fiber angle. For larger fiber angles, multiple cracks occur at locations both near and away from the load points, and the load intensity factor at failure increases sharply with increasing fiber angle.
NASA Technical Reports Server (NTRS)
Binienda, W. K.; Roberts, G. D.; Papadopoulos, D. S.
1992-01-01
The results of in-plane four-point bend experiments on unidirectionally reinforced composite beams are presented for graphite/epoxy (T300/934) and graphite/polyimide (G30-500/PMR-15) composites. The maximum load and the location of cracks formed during failure were measured for testpieces with fibers oriented at various angles to the beam axis. Since most of the beams failed near one or more of the load points, the strength of the beams was evaluated in terms of a proposed model for the local stress distribution. In this model, an exact solution to the problem of a localized contact force acting on a unidirectionally reinforced half plane is used to describe the local stress field. The stress singularity at the load points is treated in a manner similar to the stress singularity at a crack tip in fracture mechanisms problems. Using this approach, the effect of fiber angle and elastic material properties on the strength of the beam is described in terms of a load intensity factor. For fiber angles less than 45 deg from the beam axis, a single crack is initiated near one of the load points at a critical value of the load intensity factor. The critical load intensity factor decreases with increasing fiber angle. For larger fiber angles, multiple cracks occur at locations both near and away from the load points, and the load intensity factor at failure increases sharply with increasing fiber angle.
CRANS - CONFIGURABLE REAL-TIME ANALYSIS SYSTEM
NASA Technical Reports Server (NTRS)
Mccluney, K.
1994-01-01
In a real-time environment, the results of changes or failures in a complex, interconnected system need evaluation quickly. Tabulations showing the effects of changes and/or failures of a given item in the system are generally only useful for a single input, and only with regard to that item. Subsequent changes become harder to evaluate as combinations of failures produce a cascade effect. When confronted by multiple indicated failures in the system, it becomes necessary to determine a single cause. In this case, failure tables are not very helpful. CRANS, the Configurable Real-time ANalysis System, can interpret a logic tree, constructed by the user, describing a complex system and determine the effects of changes and failures in it. Items in the tree are related to each other by Boolean operators. The user is then able to change the state of these items (ON/OFF FAILED/UNFAILED). The program then evaluates the logic tree based on these changes and determines any resultant changes to other items in the tree. CRANS can also search for a common cause for multiple item failures, and allow the user to explore the logic tree from within the program. A "help" mode and a reference check provide the user with a means of exploring an item's underlying logic from within the program. A commonality check determines single point failures for an item or group of items. Output is in the form of a user-defined matrix or matrices of colored boxes, each box representing an item or set of items from the logic tree. Input is via mouse selection of the matrix boxes, using the mouse buttons to toggle the state of the item. CRANS is written in C-language and requires the MIT X Window System, Version 11 Revision 4 or Revision 5. It requires 78K of RAM for execution and a three button mouse. It has been successfully implemented on Sun4 workstations running SunOS, HP9000 workstations running HP-UX, and DECstations running ULTRIX. No executable is provided on the distribution medium; however, a sample makefile is included. Sample input files are also included. The standard distribution medium is a .25 inch streaming magnetic tape cartridge (Sun QIC-24) in UNIX tar format. Alternate distribution media and formats are available upon request. This program was developed in 1992.
Microscopic observations during longitudinal compression loading of single pulp fibers
Irving B. Sachs
1986-01-01
Paperboard components (linerboard adn corrugating medium) fail in edgewise compression because of failure of single fibers, as well as fiber-to-fiber bonds. While fiber-to-fiber-bond failure has been studied extensively, little is known about the longitudinal compression failure of a single fiber. In this study, surface alterations on single loblolly pine kraft pulp...
Adaptive Connectivity Restoration from Node Failure(s) in Wireless Sensor Networks
Wang, Huaiyuan; Ding, Xu; Huang, Cheng; Wu, Xiaobei
2016-01-01
Recently, there is a growing interest in the applications of wireless sensor networks (WSNs). A set of sensor nodes is deployed in order to collectively survey an area of interest and/or perform specific surveillance tasks in some of the applications, such as battlefield reconnaissance. Due to the harsh deployment environments and limited energy supply, nodes may fail, which impacts the connectivity of the whole network. Since a single node failure (cut-vertex) will destroy the connectivity and divide the network into disjoint blocks, most of the existing studies focus on the problem of single node failure. However, the failure of multiple nodes would be a disaster to the whole network and must be repaired effectively. Only few studies are proposed to handle the problem of multiple cut-vertex failures, which is a special case of multiple node failures. Therefore, this paper proposes a comprehensive solution to address the problems of node failure (single and multiple). Collaborative Single Node Failure Restoration algorithm (CSFR) is presented to solve the problem of single node failure only with cooperative communication, but CSFR-M, which is the extension of CSFR, handles the single node failure problem more effectively with node motion. Moreover, Collaborative Connectivity Restoration Algorithm (CCRA) is proposed on the basis of cooperative communication and node maneuverability to restore network connectivity after multiple nodes fail. CSFR-M and CCRA are reactive methods that initiate the connectivity restoration after detecting the node failure(s). In order to further minimize the energy dissipation, CCRA opts to simplify the recovery process by gridding. Moreover, the distance that an individual node needs to travel during recovery is reduced by choosing the nearest suitable candidates. Finally, extensive simulations validate the performance of CSFR, CSFR-M and CCRA. PMID:27690030
NASA Technical Reports Server (NTRS)
Peters, K. A.; Atkinson, P. F.; Hammond, E. C., Jr.
1986-01-01
Reciprocity failure was examined for IIaO spectroscopic film. Three separate experiments were performed in order to study film batch variations, thermal and aging effects in relationship to reciprocity failure, and shifting of reciprocity failure points as a function of thermal and aging effects. The failure was examined over ranges of time between 5 and 60 seconds. The variation to illuminance was obtained by using thirty neutral density filters. A standard sensitometer device imprinted the wedge pattern on the film as exposure time was subjected to variation. The results indicate that film batch differences, temperature, and aging play an important role in reciprocity failure of IIaO spectroscopic film. A shifting of the failure points was also observed in various batches of film.
Fracture in compression of brittle solids
NASA Technical Reports Server (NTRS)
1983-01-01
The fracture of brittle solids in monotonic compression is reviewed from both the mechanistic and phenomenological points of view. The fundamental theoretical developments based on the extension of pre-existing cracks in general multiaxial stress fields are recognized as explaining extrinsic behavior where a single crack is responsible for the final failure. In contrast, shear faulting in compression is recognized to be the result of an evolutionary localization process involving en echelon action of cracks and is termed intrinsic.
NASA Astrophysics Data System (ADS)
Sheikh, Muhammad; Elmarakbi, Ahmed; Elkady, Mustafa
2017-12-01
This paper focuses on state of charge (SOC) dependent mechanical failure analysis of 18650 lithium-ion battery to detect signs of thermal runaway. Quasi-static loading conditions are used with four test protocols (Rod, Circular punch, three-point bend and flat plate) to analyse the propagation of mechanical failures and failure induced temperature changes. Finite element analysis (FEA) is used to model single battery cell with the concentric layered formation which represents a complete cell. The numerical simulation model is designed with solid element formation where stell casing and all layers followed the same formation, and fine mesh is used for all layers. Experimental work is also performed to analyse deformation of 18650 lithium-ion cell. The numerical simulation model is validated with experimental results. Deformation of cell mimics thermal runaway and various thermal runaway detection strategies are employed in this work including, force-displacement, voltage-temperature, stress-strain, SOC dependency and separator failure. Results show that cell can undergo severe conditions even with no fracture or rupture, these conditions may slow to develop but they can lead to catastrophic failures. The numerical simulation technique is proved to be useful in predicting initial battery failures, and results are in good correlation with the experimental results.
Data-Driven Packet Loss Estimation for Node Healthy Sensing in Decentralized Cluster
Fan, Hangyu; Wang, Huandong; Li, Yong
2018-01-01
Decentralized clustering of modern information technology is widely adopted in various fields these years. One of the main reason is the features of high availability and the failure-tolerance which can prevent the entire system form broking down by a failure of a single point. Recently, toolkits such as Akka are used by the public commonly to easily build such kind of cluster. However, clusters of such kind that use Gossip as their membership managing protocol and use link failure detecting mechanism to detect link failures cannot deal with the scenario that a node stochastically drops packets and corrupts the member status of the cluster. In this paper, we formulate the problem to be evaluating the link quality and finding a max clique (NP-Complete) in the connectivity graph. We then proposed an algorithm that consists of two models driven by data from application layer to respectively solving these two problems. Through simulations with statistical data and a real-world product, we demonstrate that our algorithm has a good performance. PMID:29360792
Antiretroviral Treatment for Children with Peripartum Nevirapine Exposure
Palumbo, Paul; Lindsey, Jane C.; Hughes, Michael D.; Cotton, Mark F.; Bobat, Raziya; Meyers, Tammy; Bwakura-Dangarembizi, Mutsawashe; Chi, Benjamin H.; Musoke, Philippa; Kamthunzi, Portia; Schimana, Werner; Purdue, Lynette; Eshleman, Susan H.; Abrams, Elaine J.; Millar, Linda; Petzold, Elizabeth; Mofenson, Lynne M.; Jean-Philippe, Patrick; Violari, Avy
2010-01-01
BACKGROUND Single-dose nevirapine is the cornerstone of the regimen for prevention of mother-to-child transmission of human immunodeficiency virus (HIV) in resource-limited settings, but nevirapine frequently selects for resistant virus in mothers and children who become infected despite prophylaxis. The optimal antiretroviral treatment strategy for children who have had prior exposure to single-dose nevirapine is unknown. METHODS We conducted a randomized trial of initial therapy with zidovudine and lamivudine plus either nevirapine or ritonavir-boosted lopinavir in HIV-infected children 6 to 36 months of age, in six African countries, who qualified for treatment according to World Health Organization (WHO) criteria. Results are reported for the cohort that included children exposed to single-dose nevirapine prophylaxis. The primary end point was virologic failure or discontinuation of treatment by study week 24. Enrollment in this cohort was terminated early on the recommendation of the data and safety monitoring board. RESULTS A total of 164 children were enrolled. The median percentage of CD4+ lymphocytes was 19%; a total of 56% of the children had WHO stage 3 or 4 disease. More children in the nevirapine group than in the ritonavir-boosted lopinavir group reached a primary end point (39.6% vs. 21.7%; weighted difference, 18.6 percentage-points; 95% confidence interval, 3.7 to 33.6; nominal P = 0.02). Baseline resistance to nevirapine was detected in 18 of 148 children (12%) and was predictive of treatment failure. No significant between-group differences were seen in the rate of adverse events. CONCLUSIONS Among children with prior exposure to single-dose nevirapine for perinatal prevention of HIV transmission, antiretroviral treatment consisting of zidovudine and lamivudine plus ritonavir-boosted lopinavir resulted in better outcomes than did treatment with zidovudine and lamivudine plus nevirapine. Since nevirapine is used for both treatment and perinatal prevention of HIV infection in resource-limited settings, alternative strategies for the prevention of HIV transmission from mother to child, as well as for the treatment of HIV infection, are urgently required. (Funded by the National Institutes of Health; ClinicalTrials.gov number, NCT00307151.) PMID:20942667
Rock falls from Glacier Point above Camp Curry, Yosemite National Park, California
Wieczorek, Gerald F.; Snyder, James B.
1999-01-01
A series of rock falls from the north face of Glacier Point above Camp Curry, Yosemite National Park, California, have caused reexamination of the rock-fall hazard because beginning in June, 1999 a system of cracks propagated through a nearby rock mass outlining a future potential rock fall. If the estimated volume of the potential rock fall fails as a single piece, there could be a risk from rock-fall impact and airborne rock debris to cabins in Camp Curry. The role of joint plane orientation and groundwater pressure in the fractured rock mass are discussed in light of the pattern of developing cracks and potential modes of failure.
NASA Technical Reports Server (NTRS)
Peters, Kevin A.; Atkinson, Pamela F.; Hammond, Ernest C., Jr
1987-01-01
Reciprocity failure was examined for IIaO spectroscopic film. Three separate experiments were performed in order to study film batch variations, thermal and aging effects in relationship to reciprocity failure, and shifting of reciprocity failure points as a function of thermal and aging effects. The failure was examined over ranges of time between 5 and 60 seconds. The variation to illuminance was obtained by using thirty neutral density filters. A standard sensitometer device imprinted the wedge pattern on the film as exposure time was subjected to variation. Results indicate that film batch differences, temperature, and aging play an important role in reciprocity failure of IIaO spectroscopic film. A shifting of the failure points was also observed in various batches of film.
A Voyager attitude control perspective on fault tolerant systems
NASA Technical Reports Server (NTRS)
Rasmussen, R. D.; Litty, E. C.
1981-01-01
In current spacecraft design, a trend can be observed to achieve greater fault tolerance through the application of on-board software dedicated to detecting and isolating failures. Whether fault tolerance through software can meet the desired objectives depends on very careful consideration and control of the system in which the software is imbedded. The considered investigation has the objective to provide some of the insight needed for the required analysis of the system. A description is given of the techniques which have been developed in this connection during the development of the Voyager spacecraft. The Voyager Galileo Attitude and Articulation Control Subsystem (AACS) fault tolerant design is discussed to emphasize basic lessons learned from this experience. The central driver of hardware redundancy implementation on Voyager was known as the 'single point failure criterion'.
NASA Astrophysics Data System (ADS)
White, Bradley W.; Tarver, Craig M.
2017-01-01
It has long been known that detonating single crystals of solid explosives have much larger failure diameters than those of heterogeneous charges of the same explosive pressed or cast to 98 - 99% theoretical maximum density (TMD). In 1957, Holland et al. demonstrated that PETN single crystals have failure diameters of about 8 mm, whereas heterogeneous PETN charges have failure diameters of less than 0.5 mm. Recently, Fedorov et al. quantitatively determined nanosecond time resolved detonation reaction zone profiles of single crystals of PETN and HMX by measuring the interface particle velocity histories of the detonating crystals and LiF windows using a PDV system. The measured reaction zone time durations for PETN and HMX single crystal detonations were approximately 100 and 260 nanoseconds, respectively. These experiments provided the necessary data to develop Ignition and Growth (I&G) reactive flow model parameters for the single crystal detonation reaction zones. Using these parameters, the calculated unconfined failure diameter of a PETN single crystal was 7.5 +/- 0.5 mm, close to the 8 mm experimental value. The calculated failure diameter of an unconfined HMX single crystal was 15 +/- 1 mm. The unconfined failure diameter of an HMX single crystal has not yet been determined precisely, but Fedorov et al. detonated 14 mm diameter crystals confined by detonating a HMX-based plastic bonded explosive (PBX) without initially overdriving the HMX crystals.
Misra, A; Burke, JF; Ramayya, A; Jacobs, J; Sperling, MR; Moxon, KA; Kahana, MJ; Evans, JJ; Sharan, AD
2014-01-01
Objective The authors report methods developed for the implantation of micro-wire bundles into mesial temporal lobe structures and subsequent single neuron recording in epileptic patients undergoing in-patient diagnostic monitoring. This is done with the intention of lowering the perceived barriers to routine single neuron recording from deep brain structures in the clinical setting. Approach Over a 15 month period, 11 patients were implanted with platinum micro-wire bundles into mesial temporal structures. Protocols were developed for A) monitoring electrode integrity through impedance testing, B) ensuring continuous 24-7 recording, C) localizing micro-wire position and “splay” pattern and D) monitoring grounding and referencing to maintain the quality of recordings. Main Result Five common modes of failure were identified: 1) broken micro-wires from acute tensile force, 2) broken micro-wires from cyclic fatigue at stress points, 3) poor in-vivo micro-electrode separation, 4) motion artifact and 5) deteriorating ground connection and subsequent drop in common mode noise rejection. Single neurons have been observed up to 14 days post implantation and on 40% of micro-wires. Significance Long-term success requires detailed review of each implant by both the clinical and research teams to identify failure modes, and appropriate refinement of techniques while moving forward. This approach leads to reliable unit recordings without prolonging operative times, which will help increase the availability and clinical viability of human single neuron data. PMID:24608589
NASA Technical Reports Server (NTRS)
Salem, Jonathan A.
2002-01-01
A generalized reliability model was developed for use in the design of structural components made from brittle, homogeneous anisotropic materials such as single crystals. The model is based on the Weibull distribution and incorporates a variable strength distribution and any equivalent stress failure criteria. In addition to the reliability model, an energy based failure criterion for elastically anisotropic materials was formulated. The model is different from typical Weibull-based models in that it accounts for strength anisotropy arising from fracture toughness anisotropy and thereby allows for strength and reliability predictions of brittle, anisotropic single crystals subjected to multiaxial stresses. The model is also applicable to elastically isotropic materials exhibiting strength anisotropy due to an anisotropic distribution of flaws. In order to develop and experimentally verify the model, the uniaxial and biaxial strengths of a single crystal nickel aluminide were measured. The uniaxial strengths of the <100> and <110> crystal directions were measured in three and four-point flexure. The biaxial strength was measured by subjecting <100> plates to a uniform pressure in a test apparatus that was developed and experimentally verified. The biaxial strengths of the single crystal plates were estimated by extending and verifying the displacement solution for a circular, anisotropic plate to the case of a variable radius and thickness. The best correlation between the experimental strength data and the model predictions occurred when an anisotropic stress analysis was combined with the normal stress criterion and the strength parameters associated with the <110> crystal direction.
Optimizing Data Management in Grid Environments
NASA Astrophysics Data System (ADS)
Zissimos, Antonis; Doka, Katerina; Chazapis, Antony; Tsoumakos, Dimitrios; Koziris, Nectarios
Grids currently serve as platforms for numerous scientific as well as business applications that generate and access vast amounts of data. In this paper, we address the need for efficient, scalable and robust data management in Grid environments. We propose a fully decentralized and adaptive mechanism comprising of two components: A Distributed Replica Location Service (DRLS) and a data transfer mechanism called GridTorrent. They both adopt Peer-to-Peer techniques in order to overcome performance bottlenecks and single points of failure. On one hand, DRLS ensures resilience by relying on a Byzantine-tolerant protocol and is able to handle massive concurrent requests even during node churn. On the other hand, GridTorrent allows for maximum bandwidth utilization through collaborative sharing among the various data providers and consumers. The proposed integrated architecture is completely backwards-compatible with already deployed Grids. To demonstrate these points, experiments have been conducted in LAN as well as WAN environments under various workloads. The evaluation shows that our scheme vastly outperforms the conventional mechanisms in both efficiency (up to 10 times faster) and robustness in case of failures and flash crowd instances.
An Autonomous Distributed Fault-Tolerant Local Positioning System
NASA Technical Reports Server (NTRS)
Malekpour, Mahyar R.
2017-01-01
We describe a fault-tolerant, GPS-independent (Global Positioning System) distributed autonomous positioning system for static/mobile objects and present solutions for providing highly-accurate geo-location data for the static/mobile objects in dynamic environments. The reliability and accuracy of a positioning system fundamentally depends on two factors; its timeliness in broadcasting signals and the knowledge of its geometry, i.e., locations and distances of the beacons. Existing distributed positioning systems either synchronize to a common external source like GPS or establish their own time synchrony using a scheme similar to a master-slave by designating a particular beacon as the master and other beacons synchronize to it, resulting in a single point of failure. Another drawback of existing positioning systems is their lack of addressing various fault manifestations, in particular, communication link failures, which, as in wireless networks, are increasingly dominating the process failures and are typically transient and mobile, in the sense that they typically affect different messages to/from different processes over time.
Pollitz, F.F.; Schwartz, D.P.
2008-01-01
We construct a viscoelastic cycle model of plate boundary deformation that includes the effect of time-dependent interseismic strain accumulation, coseismic strain release, and viscoelastic relaxation of the substrate beneath the seismogenic crust. For a given fault system, time-averaged stress changes at any point (not on a fault) are constrained to zero; that is, kinematic consistency is enforced for the fault system. The dates of last rupture, mean recurrence times, and the slip distributions of the (assumed) repeating ruptures are key inputs into the viscoelastic cycle model. This simple formulation allows construction of stress evolution at all points in the plate boundary zone for purposes of probabilistic seismic hazard analysis (PSHA). Stress evolution is combined with a Coulomb failure stress threshold at representative points on the fault segments to estimate the times of their respective future ruptures. In our PSHA we consider uncertainties in a four-dimensional parameter space: the rupture peridocities, slip distributions, time of last earthquake (for prehistoric ruptures) and Coulomb failure stress thresholds. We apply this methodology to the San Francisco Bay region using a recently determined fault chronology of area faults. Assuming single-segment rupture scenarios, we find that fature rupture probabilities of area faults in the coming decades are the highest for the southern Hayward, Rodgers Creek, and northern Calaveras faults. This conclusion is qualitatively similar to that of Working Group on California Earthquake Probabilities, but the probabilities derived here are significantly higher. Given that fault rupture probabilities are highly model-dependent, no single model should be used to assess to time-dependent rupture probabilities. We suggest that several models, including the present one, be used in a comprehensive PSHA methodology, as was done by Working Group on California Earthquake Probabilities.
Adjusted variable plots for Cox's proportional hazards regression model.
Hall, C B; Zeger, S L; Bandeen-Roche, K J
1996-01-01
Adjusted variable plots are useful in linear regression for outlier detection and for qualitative evaluation of the fit of a model. In this paper, we extend adjusted variable plots to Cox's proportional hazards model for possibly censored survival data. We propose three different plots: a risk level adjusted variable (RLAV) plot in which each observation in each risk set appears, a subject level adjusted variable (SLAV) plot in which each subject is represented by one point, and an event level adjusted variable (ELAV) plot in which the entire risk set at each failure event is represented by a single point. The latter two plots are derived from the RLAV by combining multiple points. In each point, the regression coefficient and standard error from a Cox proportional hazards regression is obtained by a simple linear regression through the origin fit to the coordinates of the pictured points. The plots are illustrated with a reanalysis of a dataset of 65 patients with multiple myeloma.
Care management for low-risk patients with heart failure: a randomized, controlled trial.
DeBusk, Robert Frank; Miller, Nancy Houston; Parker, Kathleen Marie; Bandura, Albert; Kraemer, Helena Chmura; Cher, Daniel Joseph; West, Jeffrey Alan; Fowler, Michael Bruce; Greenwald, George
2004-10-19
Nurse care management programs for patients with chronic illness have been shown to be safe and effective. To determine whether a telephone-mediated nurse care management program for heart failure reduced the rate of rehospitalization for heart failure and for all causes over a 1-year period. Randomized, controlled trial of usual care with nurse management versus usual care alone in patients hospitalized for heart failure from May 1998 through October 2001. 5 northern California hospitals in a large health maintenance organization. Of 2786 patients screened, 462 met clinical criteria for heart failure and were randomly assigned (228 to intervention and 234 to usual care). Nurse care management provided structured telephone surveillance and treatment for heart failure and coordination of patients' care with primary care physicians. Time to first rehospitalization for heart failure or for any cause and time to a combined end point of first rehospitalization, emergency department visit, or death. At 1 year, half of the patients had been rehospitalized at least once and 11% had died. Only one third of rehospitalizations were for heart failure. The rate of first rehospitalization for heart failure was similar in both groups (proportional hazard, 0.85 [95% CI, 0.46 to 1.57]). The rate of all-cause rehospitalization was similar (proportional hazard, 0.98 [CI, 0.76 to 1.27]). The findings of this study, conducted in a single health care system, may not be generalizable to other health care systems. The overall effect of the intervention was minor. Among patients with heart failure at low risk on the basis of sociodemographic and medical attributes, nurse care management did not statistically significantly reduce rehospitalizations for heart failure or for any cause. Such programs may be less effective for patients at low risk than those at high risk.
The palliative care in heart failure trial: rationale and design.
Mentz, Robert J; Tulsky, James A; Granger, Bradi B; Anstrom, Kevin J; Adams, Patricia A; Dodson, Gwen C; Fiuzat, Mona; Johnson, Kimberly S; Patel, Chetan B; Steinhauser, Karen E; Taylor, Donald H; O'Connor, Christopher M; Rogers, Joseph G
2014-11-01
The progressive nature of heart failure (HF) coupled with high mortality and poor quality of life mandates greater attention to palliative care as a routine component of advanced HF management. Limited evidence exists from randomized, controlled trials supporting the use of interdisciplinary palliative care in HF. PAL-HF is a prospective, controlled, unblinded, single-center study of an interdisciplinary palliative care intervention in 200 patients with advanced HF estimated to have a high likelihood of mortality or rehospitalization in the ensuing 6 months. The 6-month PAL-HF intervention focuses on physical and psychosocial symptom relief, attention to spiritual concerns, and advanced care planning. The primary end point is health-related quality of life measured by the Kansas City Cardiomyopathy Questionnaire and the Functional Assessment of Chronic Illness Therapy with Palliative Care Subscale score at 6 months. Secondary end points include changes in anxiety/depression, spiritual well-being, caregiver satisfaction, cost and resource utilization, and a composite of death, HF hospitalization, and quality of life. PAL-HF is a randomized, controlled clinical trial that will help evaluate the efficacy and cost effectiveness of palliative care in advanced HF using a patient-centered outcome as well as clinical and economic end points. Copyright © 2014 Elsevier Inc. All rights reserved.
Jackson, Timothy J; Jarrell, Shelby E; Adamson, Gregory J; Chung, Kyung Chil; Lee, Thay Q
2016-07-01
The main purpose of this study was to examine the functional characteristics of the anterior and posterior bands of the anterior bundle of the ulnar collateral ligament (UCL). Six cadaveric elbows were tested using a digital tracking system to measure the strain in the anterior band and posterior band of the anterior bundle of the UCL throughout a flexion/extension arc. The specimens were then placed in an Instron materials testing machine and loaded to failure to determine yield load and ultimate load of the UCL. The posterior band showed a linear increase in strain with increasing degrees of elbow flexion while the anterior band showed minimal change in strain throughout. The bands showed similar strain at yield load and ultimate load, demonstrating similar intrinsic properties. The anterior band of the anterior bundle of the UCL shows an isometric strain pattern through elbow range of motion, while the posterior band shows an increasing strain pattern in higher degrees of elbow flexion. Both bands show similar strain in a load to failure model, indicating insertion point, not intrinsic differences, of the bands determine the function of the anterior bundle of the UCL. This demonstrates a biomechanical rationale for UCL reconstructions using single point anatomical insertion points.
How securely is the testicular artery occluded in the spermatic cord by using a ligature?
Rijkenhuizen, A B M; Sommerauer, S; Fasching, M; Velde, K; Peham, C
2013-09-01
There are no studies on the ideal ligature technique for the spermatic cord. To compare the maximal resistance pressure in the testicular artery and the maximal tensile forces to produce failure of 2 different ligature techniques used for ligation of the equine spermatic cord. The capabilities of 2 types of ligatures, single knot loop and double knot loop, were assessed using a pressure-resistance test in testicular arteries and with an in vitro mechanical evaluation of the tensile strength by single cycle-to-failure testing. In the pressure-resistance test, the mean ± s.d. peak force at failure of the single knot loop was 354.4 ± 91.7 mmHg and for the double knot loop 303.2 ± 62.0 mmHg. There was no significant difference between the maximal load to failure of the single knot loop and double knot loop technique. The pressure needed for rupture was significantly higher (P = 0.001) than for leakage. The maximal tensile force at failure of the single knot loop was significantly higher than the double knot loop (P = 0.028). There was no significant difference in load elongation properties to failure between the single knot loop and double knot loop. Although no significant differences were obtained in the pressure-resistance test, the single knot loop sustained significantly greater load to failure than the double knot loop in single cycle-to-failure testing. Based on these findings, it would appear that the performance of the single knot loop should be superior to the double knot loop. Both ligature techniques are able to withstand the normal physiological intravascular pressure. The single knot loop has the greater breaking strength of the 2 ligatures tested and is less time consuming to perform and may therefore have advantages during equine castration. © 2012 EVJ Ltd.
Antimicrobial resistance in Neisseria gonorrhoeae in the UK: surveillance and management.
Ison, Catherine A; Alexander, Sarah
2011-10-01
Successful antimicrobial therapy is fundamental to the public health control of gonorrhea, in the absence of a protective immune response. Neisseria gonorrhoeae, the causative agent, has presented a constant challenge for the provision of such therapy as it has demonstrated the ability to become resistant to successive highly active agents chosen for first-line treatment. Acquisition of plasmids from other bacteria and long-term use of a single agent has selected both single step high-level and low-level resistance due to multiple mutations. While therapeutic failure of the current recommended agents cefixime and ceftriaxone begins to emerge, choice of alternative therapies is limited. Guidelines for therapy will be dependent on surveillance programs but individual patient management will require a viable organism to detect emerging resistance. Advances in molecular detection, while advantageous for the diagnosis of gonorrhea, fail to provide a viable organism, posing even greater challenges for the definition of treatment failure, and appropriate end points for test of cure. Innovative and collaborative approaches will be essential to maintain gonorrhea as a treatable infection.
Approximation of Failure Probability Using Conditional Sampling
NASA Technical Reports Server (NTRS)
Giesy. Daniel P.; Crespo, Luis G.; Kenney, Sean P.
2008-01-01
In analyzing systems which depend on uncertain parameters, one technique is to partition the uncertain parameter domain into a failure set and its complement, and judge the quality of the system by estimating the probability of failure. If this is done by a sampling technique such as Monte Carlo and the probability of failure is small, accurate approximation can require so many sample points that the computational expense is prohibitive. Previous work of the authors has shown how to bound the failure event by sets of such simple geometry that their probabilities can be calculated analytically. In this paper, it is shown how to make use of these failure bounding sets and conditional sampling within them to substantially reduce the computational burden of approximating failure probability. It is also shown how the use of these sampling techniques improves the confidence intervals for the failure probability estimate for a given number of sample points and how they reduce the number of sample point analyses needed to achieve a given level of confidence.
Definition of a Robust Supervisory Control Scheme for Sodium-Cooled Fast Reactors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ponciroli, R.; Passerini, S.; Vilim, R. B.
In this work, an innovative control approach for metal-fueled Sodium-cooled Fast Reactors is proposed. With respect to the classical approach adopted for base-load Nuclear Power Plants, an alternative control strategy for operating the reactor at different power levels by respecting the system physical constraints is presented. In order to achieve a higher operational flexibility along with ensuring that the implemented control loops do not influence the system inherent passive safety features, a dedicated supervisory control scheme for the dynamic definition of the corresponding set-points to be supplied to the PID controllers is designed. In particular, the traditional approach based onmore » the adoption of tabulated lookup tables for the set-point definition is found not to be robust enough when failures of the implemented SISO (Single Input Single Output) actuators occur. Therefore, a feedback algorithm based on the Reference Governor approach, which allows for the optimization of reference signals according to the system operating conditions, is proposed.« less
Start Up Application Concerns with Field Programmable Gate Arrays (FPGAs)
NASA Technical Reports Server (NTRS)
Katz, Richard B.
1999-01-01
This note is being published to improve the visibility of this subject, as we continue to see problems surface in designs, as well as to add additional information to the previously published note for design engineers. The original application note focused on designing systems with no single point failures using Actel Field Programmable Gate Arrays (FPGAs) for critical applications. Included in that note were the basic principles of operation of the Actel FPGA and a discussion of potential single-point failures. The note also discussed the issue of startup transients for that class of device. It is unfortunate that we continue to see some design problems using these devices. This note will focus on the startup properties of certain electronic components, in general, and current Actel FPGAs, in particular. Devices that are "power-on friendly" are currently being developed by Actel, as a variant of the new SX series of FPGAs. In the ideal world, electronic components would behave much differently than they do in the real world, The chain, of course, starts with the power supply. Ideally, the voltage will immediately rise to a stable V(sub cc) level, of course, it does not. Aside from practical design considerations, inrush current limits of certain capacitors must be observed and the power supply's output may be intentionally slew rate limited to prevent a large current spike on the system power bus. In any event, power supply rise time may range from less than I msec to 100 msec or more.
Analysis and experiments for composite laminates with holes and subjected to 4-point bending
NASA Technical Reports Server (NTRS)
Shuart, M. J.; Prasad, C. B.
1990-01-01
Analytical and experimental results are presented for composite laminates with a hole and subjected to four-point bending. A finite-plate analysis is used to predict moment and strain distributions for six-layer quasi-isotropic laminates and transverse-ply laminates. Experimental data are compared with the analytical results. Experimental and analytical strain results show good agreement for the quasi-isotropic laminates. Failure of the two types of composite laminates is described, and failure strain results are presented as a function of normalized hole diameter. The failure results suggest that the initial failure mechanism for laminates subjected to four-point bending are similar to the initial failure mechanisms for corresponding laminates subjected to uniaxial inplane loadings.
NASA Astrophysics Data System (ADS)
Baró, Jordi; Davidsen, Jörn
2018-03-01
The hypothesis of critical failure relates the presence of an ultimate stability point in the structural constitutive equation of materials to a divergence of characteristic scales in the microscopic dynamics responsible for deformation. Avalanche models involving critical failure have determined common universality classes for stick-slip processes and fracture. However, not all empirical failure processes exhibit the trademarks of criticality. The rheological properties of materials introduce dissipation, usually reproduced in conceptual models as a hardening of the coarse grained elements of the system. Here, we investigate the effects of transient hardening on (i) the activity rate and (ii) the statistical properties of avalanches. We find the explicit representation of transient hardening in the presence of generalized viscoelasticity and solve the corresponding mean-field model of fracture. In the quasistatic limit, the accelerated energy release is invariant with respect to rheology and the avalanche propagation can be reinterpreted in terms of a stochastic counting process. A single universality class can be defined from such analogy, and all statistical properties depend only on the distance to criticality. We also prove that interevent correlations emerge due to the hardening—even in the quasistatic limit—that can be interpreted as "aftershocks" and "foreshocks."
Compression of laminated composite beams with initial damage
NASA Technical Reports Server (NTRS)
Breivik, Nicole L.; Gurdal, Zafer; Griffin, O. H., Jr.
1993-01-01
The effect of isolated damage modes on the compressive strength and failure characteristics of laminated composite test specimens were evaluated experimentally and numerically. In addition to specimens without initial damage, specimens with three types of initial damage were considered: (1) specimens with short delaminations distributed evenly through the specimen thickness, (2) specimens with few long delaminations, and (3) specimens with local fiber damage in the surface plies under the three-point bend contact point. It was found that specimens with short multiple delamination experienced the greatest reduction in compression strength compared to the undamaged specimens. Single delaminations far from the specimen surface had little effect on the final compression strength, and moderate strength reduction was observed for specimens with localized surface ply damage.
Mass and Reliability Source (MaRS) Database
NASA Technical Reports Server (NTRS)
Valdenegro, Wladimir
2017-01-01
The Mass and Reliability Source (MaRS) Database consolidates components mass and reliability data for all Oribital Replacement Units (ORU) on the International Space Station (ISS) into a single database. It was created to help engineers develop a parametric model that relates hardware mass and reliability. MaRS supplies relevant failure data at the lowest possible component level while providing support for risk, reliability, and logistics analysis. Random-failure data is usually linked to the ORU assembly. MaRS uses this data to identify and display the lowest possible component failure level. As seen in Figure 1, the failure point is identified to the lowest level: Component 2.1. This is useful for efficient planning of spare supplies, supporting long duration crewed missions, allowing quicker trade studies, and streamlining diagnostic processes. MaRS is composed of information from various databases: MADS (operating hours), VMDB (indentured part lists), and ISS PART (failure data). This information is organized in Microsoft Excel and accessed through a program made in Microsoft Access (Figure 2). The focus of the Fall 2017 internship tour was to identify the components that were the root cause of failure from the given random-failure data, develop a taxonomy for the database, and attach material headings to the component list. Secondary objectives included verifying the integrity of the data in MaRS, eliminating any part discrepancies, and generating documentation for future reference. Due to the nature of the random-failure data, data mining had to be done manually without the assistance of an automated program to ensure positive identification.
Identifying the necessary and sufficient number of risk factors for predicting academic failure.
Lucio, Robert; Hunt, Elizabeth; Bornovalova, Marina
2012-03-01
Identifying the point at which individuals become at risk for academic failure (grade point average [GPA] < 2.0) involves an understanding of which and how many factors contribute to poor outcomes. School-related factors appear to be among the many factors that significantly impact academic success or failure. This study focused on 12 school-related factors. Using a thorough 5-step process, we identified which unique risk factors place one at risk for academic failure. Academic engagement, academic expectations, academic self-efficacy, homework completion, school relevance, school safety, teacher relationships (positive relationship), grade retention, school mobility, and school misbehaviors (negative relationship) were uniquely related to GPA even after controlling for all relevant covariates. Next, a receiver operating characteristic curve was used to determine a cutoff point for determining how many risk factors predict academic failure (GPA < 2.0). Results yielded a cutoff point of 2 risk factors for predicting academic failure, which provides a way for early identification of individuals who are at risk. Further implications of these findings are discussed. PsycINFO Database Record (c) 2012 APA, all rights reserved.
Single-row versus double-row repair of the distal Achilles tendon: a biomechanical comparison.
Pilson, Holly; Brown, Philip; Stitzel, Joel; Scott, Aaron
2012-01-01
Surgery for recalcitrant insertional Achilles tendinopathy often consists of partial or total release of the insertion site, debridement of the diseased portion of the tendon, calcaneal ostectomy, and reattachment of the Achilles to the calcaneus. Although single-row and double-row techniques exist for repair of the detached Achilles tendon, biomechanical data are lacking to support one technique over the other. Based on data extrapolated from the study of rotator cuff repairs, we hypothesized that a double-row construct would provide superior fixation strength over a single-row repair. Eighteen human cadaveric Achilles tendons (9 matched pairs) with attached calcanei were repaired with single-row or double-row techniques. Specimens were mounted in a servohydraulic materials testing machine, subjected to a preconditioning cycle, and loaded to failure. Failure was defined as suture breakage or pullout, midsubstance tendon rupture, or anchor pullout. Among the failures were 12 suture failures, 5 proximal-row anchor failures, and 1 distal-row anchor failure. No midsubstance tendon ruptures or testing apparatus failures were observed. There were no statistically significant differences in the peak load to failure between the single-row and double-row repairs (p = .46). Similarly, no significant differences were observed with regards to mean energy expenditure to failure (p = .069). The present study demonstrated no biomechanical advantages of the double-row repair over a single-row repair. Despite the lack of a clear biomechanical advantage, there may exist clinical advantages of a double-row repair, such as reduction in knot prominence and restoration of the Achilles footprint. Copyright © 2012 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.
Baums, M H; Buchhorn, G H; Gilbert, F; Spahn, G; Schultz, W; Klinger, H-M
2010-09-01
This experimental study aimed to compare the load-to-failure rate and stiffness of single- versus double-row suture techniques for repairing rotator cuff lesions using two different suture materials. Additionally, the mode of failure of each repair was evaluated. In 32 sheep shoulders, a standardized tear of the infraspinatus tendon was created. Then, n = 8 specimen were randomized to four repair methods: (1) Double-row Anchor Ethibond coupled with polyester sutures, USP No. 2; (2) Double-Row Anchor HiFi with polyblend polyethylene sutures, USP No. 2; (3) Single-Row Anchor Ethibond coupled with braided polyester sutures, USP No. 2; and (4) Single-Row Anchor HiFi with braided polyblend polyethylene sutures, USP No. 2. Arthroscopic Mason-Allen stitches were placed (single-row) and combined with medial horizontal mattress stitches (double-row). All specimens were loaded to failure at a constant displacement rate on a material testing machine. Group 4 showed lowest load-to-failure result with 155.7 +/- 31.1 N compared to group 1 (293.4 +/- 16.1 N) and group 2 (397.7 +/- 7.4 N) (P < 0.001). Stiffness was highest in group 2 (162 +/- 7.3 N/mm) and lowest in group 4 (84.4 +/- 19.9 mm) (P < 0.001). In group 4, the main cause of failure was due to the suture cutting through the tendon (n = 6), a failure case observed in only n = 1 specimen in group 2 (P < 0.001). A double-row technique combined with arthroscopic Mason-Allen/horizontal mattress stitches provides high initial failure strength and may minimize the risk of the polyethylene sutures cutting through the tendon in rotator cuff repair when a single load force is used.
Park, Sung-Soo; Kim, Hee-Je; Min, Kyoung Il; Min, Gi June; Jeon, Young-Woo; Yoon, Jae-Ho; Yahng, Seung-Ah; Shin, Seung-Hwan; Lee, Sung-Eun; Cho, Byung-Sik; Eom, Ki-Seong; Kim, Yoo-Jin; Lee, Seok; Min, Chang-Ki; Cho, Seok-Goo; Kim, Dong-Wook; Lee, Jong Wook; Min, Woo-Sung
2018-04-01
To identify factors affecting survival outcomes and to develop a prognostic model for second allogeneic stem-cell transplantation (allo-SCT2) for relapsed acute myeloid leukemia (AML) after the first autologous or allogeneic stem-cell transplantation. Seventy-eight consecutive adult AML patients who received allo-SCT2 were analyzed in this retrospective study. The 4-year overall survival (OS) rate was 28.7%. In multivariate analysis, poor cytogenetic risk at diagnosis, circulating blast ≥ 20% at relapse, duration from first transplantation to relapse < 9 months, and failure to achieve morphologic complete remission after allo-SCT2 were factors associated with poor OS. A prognostic model was developed with the following score system: intermediate and poor cytogenetic risk at diagnosis (0.5 and 1 point), peripheral blast ≥ 20% at relapse (1 point), duration from the first transplantation to relapse < 9 months (1 point), and failure to achieve morphologic complete remission after allo-SCT2 (1 point). The model identified 2 subgroups according to the 4-year OS rate: 51.3% in the low-risk group (score < 2) and 2.8% in the high-risk group (score ≥ 2) (P < .001). This prognostic model might be useful to make an appropriate decision for allo-SCT2 in relapsed AML after the first autologous or allogeneic stem-cell transplantation. Copyright © 2018 Elsevier Inc. All rights reserved.
Reliability of Fault Tolerant Control Systems. Part 1
NASA Technical Reports Server (NTRS)
Wu, N. Eva
2001-01-01
This paper reports Part I of a two part effort, that is intended to delineate the relationship between reliability and fault tolerant control in a quantitative manner. Reliability analysis of fault-tolerant control systems is performed using Markov models. Reliability properties, peculiar to fault-tolerant control systems are emphasized. As a consequence, coverage of failures through redundancy management can be severely limited. It is shown that in the early life of a syi1ein composed of highly reliable subsystems, the reliability of the overall system is affine with respect to coverage, and inadequate coverage induces dominant single point failures. The utility of some existing software tools for assessing the reliability of fault tolerant control systems is also discussed. Coverage modeling is attempted in Part II in a way that captures its dependence on the control performance and on the diagnostic resolution.
Toe transfer in congenital hand malformations.
Foucher, G; Medina, J; Navarro, R; Nagel, D
2001-01-01
Fifty-eight patients with congenital hand abnormalities underwent 65 toe-to-hand transfers. Symbrachydactyly (51 cases) was the most frequent indication. Forty-seven second toe-to-hand transfers were performed in 44 patients. The mean follow-up time was 5.2 years. Two failures occurred in cases in which only one artery was anastomosed; no failures were noted when more than one artery fed the transfer. Two patients with a single second-toe transfer presented with lateral instability of the transferred metatarsophalangeal joint. The mean active range of motion was 38 degrees, with a mean extension lag of 25 degrees. The mean two-point discrimination was 5 mm. Forty-one patients used the transferred toe well, when performing activities of daily living and playing games. Toe-to-hand transfer, prior to the establishment of the grip pattern, facilitates integration of the transfer.
Contextualizing Genetics for Regional Heart Failure Care
Iyngkaran, Pupalan; Thomas, Merlin C.; Johnson, Renee; French, John; Ilton, Marcus; McDonald, Peter; Hare, David L.; Fatkin, Diane
2016-01-01
Congestive heart failure (CHF) is a chronic and often devastating cardiovascular disorder with no cure. There has been much advancement in the last two decades that has seen improvements in morbidity and mortality. Clinicians have also noted variations in the responses to therapies. More detailed observations also point to clusters of diseases, phenotypic groupings, unusual severity and the rates at which CHF occurs. Medical genetics is playing an increasingly important role in answering some of these observations. This developing field in many respects provides more information than is currently clinically applicable. This includes making sense of the established single gene mutations or uncommon private mutations. In this thematic series which discusses the many factors that could be relevant for CHF care, once established treatments are available in the communities; this section addresses a contextual role for medical genetics. PMID:27280306
Real-time estimation of ionospheric delay using GPS measurements
NASA Astrophysics Data System (ADS)
Lin, Lao-Sheng
1997-12-01
When radio waves such as the GPS signals propagate through the ionosphere, they experience an extra time delay. The ionospheric delay can be eliminated (to the first order) through a linear combination of L1 and L2 observations from dual-frequency GPS receivers. Taking advantage of this dispersive principle, one or more dual- frequency GPS receivers can be used to determine a model of the ionospheric delay across a region of interest and, if implemented in real-time, can support single-frequency GPS positioning and navigation applications. The research objectives of this thesis were: (1) to develop algorithms to obtain accurate absolute Total Electron Content (TEC) estimates from dual-frequency GPS observables, and (2) to develop an algorithm to improve the accuracy of real-time ionosphere modelling. In order to fulfil these objectives, four algorithms have been proposed in this thesis. A 'multi-day multipath template technique' is proposed to mitigate the pseudo-range multipath effects at static GPS reference stations. This technique is based on the assumption that the multipath disturbance at a static station will be constant if the physical environment remains unchanged from day to day. The multipath template, either single-day or multi-day, can be generated from the previous days' GPS data. A 'real-time failure detection and repair algorithm' is proposed to detect and repair the GPS carrier phase 'failures', such as the occurrence of cycle slips. The proposed algorithm uses two procedures: (1) application of a statistical test on the state difference estimated from robust and conventional Kalman filters in order to detect and identify the carrier phase failure, and (2) application of a Kalman filter algorithm to repair the 'identified carrier phase failure'. A 'L1/L2 differential delay estimation algorithm' is proposed to estimate GPS satellite transmitter and receiver L1/L2 differential delays. This algorithm, based on the single-site modelling technique, is able to estimate the sum of the satellite and receiver L1/L2 differential delay for each tracked GPS satellite. A 'UNSW grid-based algorithm' is proposed to improve the accuracy of real-time ionosphere modelling. The proposed algorithm is similar to the conventional grid-based algorithm. However, two modifications were made to the algorithm: (1) an 'exponential function' is adopted as the weighting function, and (2) the 'grid-based ionosphere model' estimated from the previous day is used to predict the ionospheric delay ratios between the grid point and reference points. (Abstract shortened by UMI.)
Januzzi, James L; Butler, Javed; Fombu, Emmanuel; Maisel, Alan; McCague, Kevin; Piña, Ileana L; Prescott, Margaret F; Riebman, Jerome B; Solomon, Scott
2018-05-01
Sacubitril/valsartan is an angiotensin receptor-neprilysin inhibitor indicated for the treatment of patients with chronic heart failure (HF) with reduced ejection fraction; however, its mechanism of benefit remains unclear. Biomarkers that are linked to ventricular remodeling, myocardial injury, and fibrosis may provide mechanistic insight and important clinical guidance regarding sacubitril/valsartan use. This 52-week, multicenter, open-label, single-arm study is designed to (1) correlate biomarker changes with cardiac remodeling parameters, cardiovascular outcomes, and patient-reported outcome data and (2) determine short- and long-term changes in concentrations of biomarkers related to potential mechanisms of action and effects of sacubitril/valsartan therapy. Approximately 830 patients with HF with reduced ejection fraction will be initiated and titrated on sacubitril/valsartan according to United States prescribing information. Primary efficacy end points include the changes in N-terminal pro-B-type natriuretic peptide concentrations and cardiac remodeling from baseline to 1 year. Secondary end points include changes in concentrations of N-terminal pro-B-type natriuretic peptide and remodeling to 6 months, and changes in patient-reported outcomes using the Kansas City Cardiomyopathy Questionnaire-23 from baseline to 1 year. In addition, several other relevant biomarkers will be measured. Biomarker changes relative to the number of cardiovascular events in 12 months will also be assessed as exploratory end points. Results from the Prospective Study of Biomarkers, Symptom Improvement, and Ventricular Remodeling During Sacubitril/Valsartan Therapy for Heart Failure (PROVE-HF) will help establish a mechanistic understanding of angiotensin receptor-neprilysin inhibitor therapeutic benefits and provide clinicians with clarity on how to interpret information on biomarkers during treatment (PROVE-HF ClinicalTrials.gov identifier: NCT02887183). Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Mansur, M. Hossein; Schroeder, Jeffery A.
1988-01-01
A moving-base simulation was conducted to investigate a pilot's ability to recover from transients following single-axis hard-over failures of the flight-control system. The investigation was performed in conjunction with a host simulation that examined the influence of control modes on a single pilot's ability to perform various mission elements under high-workload conditions. The NASA Ames large-amplitude-motion Vertical Motion Simulator (VMS) was utilized, and the experimental variables were the failure axis, the severity of the failure, and the airspeed at which the failure occurred. Other factors, such as pilot workload and terrain and obstacle proximity at the time of failure, were kept as constant as possible within the framework of the host simulation task scenarios. No explicit failure warnings were presented to the pilot. Data from the experiment are shown, and pilot ratings are compared with the proposed handling-qualities requirements for military rotorcraft. Results indicate that the current proposed failure transient requirements may need revision.
Valve system incorporating single failure protection logic
Ryan, Rodger; Timmerman, Walter J. H.
1980-01-01
A valve system incorporating single failure protective logic. The system consists of a valve combination or composite valve which allows actuation or de-actuation of a device such as a hydraulic cylinder or other mechanism, integral with or separate from the valve assembly, by means of three independent input signals combined in a function commonly known as two-out-of-three logic. Using the input signals as independent and redundant actuation/de-actuation signals, a single signal failure, or failure of the corresponding valve or valve set, will neither prevent the desired action, nor cause the undesired action of the mechanism.
Ye, Qing; Pan, Hao; Liu, Changhua
2015-01-01
This research proposes a novel framework of final drive simultaneous failure diagnosis containing feature extraction, training paired diagnostic models, generating decision threshold, and recognizing simultaneous failure modes. In feature extraction module, adopt wavelet package transform and fuzzy entropy to reduce noise interference and extract representative features of failure mode. Use single failure sample to construct probability classifiers based on paired sparse Bayesian extreme learning machine which is trained only by single failure modes and have high generalization and sparsity of sparse Bayesian learning approach. To generate optimal decision threshold which can convert probability output obtained from classifiers into final simultaneous failure modes, this research proposes using samples containing both single and simultaneous failure modes and Grid search method which is superior to traditional techniques in global optimization. Compared with other frequently used diagnostic approaches based on support vector machine and probability neural networks, experiment results based on F 1-measure value verify that the diagnostic accuracy and efficiency of the proposed framework which are crucial for simultaneous failure diagnosis are superior to the existing approach. PMID:25722717
23 CFR 668.107 - Federal share payable.
Code of Federal Regulations, 2012 CFR
2012-04-01
... natural disaster or catastrophic failure may amount to 100 percent of the costs thereof. (b) Total... those on Federal roads under 23 CFR part 668, subpart B), resulting from a single natural disaster or a single catastrophic failure, shall not exceed $100 million per disaster or catastrophic failure. The...
23 CFR 668.107 - Federal share payable.
Code of Federal Regulations, 2010 CFR
2010-04-01
... natural disaster or catastrophic failure may amount to 100 percent of the costs thereof. (b) Total... those on Federal roads under 23 CFR part 668, subpart B), resulting from a single natural disaster or a single catastrophic failure, shall not exceed $100 million per disaster or catastrophic failure. The...
23 CFR 668.107 - Federal share payable.
Code of Federal Regulations, 2014 CFR
2014-04-01
... natural disaster or catastrophic failure may amount to 100 percent of the costs thereof. (b) Total... those on Federal roads under 23 CFR part 668, subpart B), resulting from a single natural disaster or a single catastrophic failure, shall not exceed $100 million per disaster or catastrophic failure. The...
23 CFR 668.107 - Federal share payable.
Code of Federal Regulations, 2011 CFR
2011-04-01
... natural disaster or catastrophic failure may amount to 100 percent of the costs thereof. (b) Total... those on Federal roads under 23 CFR part 668, subpart B), resulting from a single natural disaster or a single catastrophic failure, shall not exceed $100 million per disaster or catastrophic failure. The...
23 CFR 668.107 - Federal share payable.
Code of Federal Regulations, 2013 CFR
2013-04-01
... natural disaster or catastrophic failure may amount to 100 percent of the costs thereof. (b) Total... those on Federal roads under 23 CFR part 668, subpart B), resulting from a single natural disaster or a single catastrophic failure, shall not exceed $100 million per disaster or catastrophic failure. The...
First-Ply-Failure Performance of Composite Clamped Spherical Shells
NASA Astrophysics Data System (ADS)
Ghosh, A.; Chakravorty, D.
2018-05-01
The failure aspects of composites are available for plates, but studies of the literature on shells unveils that similar reports on them are very limited in number. The aim of this work was to investigate the first-ply-failure of industrially and aesthetically important spherical shells under uniform loadings. Apart from solving benchmark problems, numerical experiments were carried out with different variations of their parameters to obtain the first-ply-failure stresses by using the finite-element method. The load was increased in steps, and the lamina strains and stresses were put into well-established failure criteria to evaluate their first-ply-failure stress, the failed ply, the point of initiation of failure, and failure modes and tendencies. The results obtained are analyzed to extract the points of engineering significance.
Effect and clinical prediction of worsening renal function in acute decompensated heart failure.
Breidthardt, Tobias; Socrates, Thenral; Noveanu, Markus; Klima, Theresia; Heinisch, Corinna; Reichlin, Tobias; Potocki, Mihael; Nowak, Albina; Tschung, Christopher; Arenja, Nisha; Bingisser, Roland; Mueller, Christian
2011-03-01
We aimed to establish the prevalence and effect of worsening renal function (WRF) on survival among patients with acute decompensated heart failure. Furthermore, we sought to establish a risk score for the prediction of WRF and externally validate the previously established Forman risk score. A total of 657 consecutive patients with acute decompensated heart failure presenting to the emergency department and undergoing serial creatinine measurements were enrolled. The potential of the clinical parameters at admission to predict WRF was assessed as the primary end point. The secondary end point was all-cause mortality at 360 days. Of the 657 patients, 136 (21%) developed WRF, and 220 patients had died during the first year. WRF was more common in the nonsurvivors (30% vs 41%, p = 0.03). Multivariate regression analysis found WRF to independently predict mortality (hazard ratio 1.92, p <0.01). In a single parameter model, previously diagnosed chronic kidney disease was the only independent predictor of WRF and achieved an area under the receiver operating characteristic curve of 0.60. After the inclusion of the blood gas analysis parameters into the model history of chronic kidney disease (hazard ratio 2.13, p = 0.03), outpatient diuretics (hazard ratio 5.75, p <0.01), and bicarbonate (hazard ratio 0.91, p <0.01) were all predictive of WRF. A risk score was developed using these predictors. On receiver operating characteristic curve analysis, the Forman and Basel prediction rules achieved an area under the curve of 0.65 and 0.71, respectively. In conclusion, WRF was common in patients with acute decompensated heart failure and was linked to significantly worse outcomes. However, the clinical parameters failed to adequately predict its occurrence, making a tailored therapy approach impossible. Copyright © 2011 Elsevier Inc. All rights reserved.
Dynamic fracture behavior of single and contacting Poly(methyl methacrylate) particles
DOE Office of Scientific and Technical Information (OSTI.GOV)
Parab, Niranjan D.; Guo, Zherui; Hudspeth, Matthew C.
Fracture behaviors of single, two, and multiple contacting spherical Poly (methyl methacrylate) (PMMA) particles were recorded using high speed synchrotron X-ray phase contrast imaging. A miniaturized Kolsky bar setup was used to apply dynamic compressive loading on the PMMA particles. In both single and two particle experiments, cracking initiated near the center of the particles and propagated towards the contacts. The crack bifurcated near the contact points for single particle experiments, thus forming conical fragments. The crack bifurcation and subsequent conical fragment formation was observed only at the particle-particle contact for two particle experiments. The particles were observed to fracturemore » in hemispherical fragments normal to the contact plane in the multiparticle experiments. The observed failure mechanisms strongly suggest that the maximum tensile stress near the center of the particle is the critical parameter governing fracture of the particles. Moreover, the compressive stress under the contact areas led to the bifurcation and subsequent conical fragment formation.« less
Dynamic fracture behavior of single and contacting Poly(methyl methacrylate) particles
Parab, Niranjan D.; Guo, Zherui; Hudspeth, Matthew C.; ...
2017-09-19
Fracture behaviors of single, two, and multiple contacting spherical Poly (methyl methacrylate) (PMMA) particles were recorded using high speed synchrotron X-ray phase contrast imaging. A miniaturized Kolsky bar setup was used to apply dynamic compressive loading on the PMMA particles. In both single and two particle experiments, cracking initiated near the center of the particles and propagated towards the contacts. The crack bifurcated near the contact points for single particle experiments, thus forming conical fragments. The crack bifurcation and subsequent conical fragment formation was observed only at the particle-particle contact for two particle experiments. The particles were observed to fracturemore » in hemispherical fragments normal to the contact plane in the multiparticle experiments. The observed failure mechanisms strongly suggest that the maximum tensile stress near the center of the particle is the critical parameter governing fracture of the particles. Moreover, the compressive stress under the contact areas led to the bifurcation and subsequent conical fragment formation.« less
Pilots Rate Augmented Generalized Predictive Control for Reconfiguration
NASA Technical Reports Server (NTRS)
Soloway, Don; Haley, Pam
2004-01-01
The objective of this paper is to report the results from the research being conducted in reconfigurable fight controls at NASA Ames. A study was conducted with three NASA Dryden test pilots to evaluate two approaches of reconfiguring an aircraft's control system when failures occur in the control surfaces and engine. NASA Ames is investigating both a Neural Generalized Predictive Control scheme and a Neural Network based Dynamic Inverse controller. This paper highlights the Predictive Control scheme where a simple augmentation to reduce zero steady-state error led to the neural network predictor model becoming redundant for the task. Instead of using a neural network predictor model, a nominal single point linear model was used and then augmented with an error corrector. This paper shows that the Generalized Predictive Controller and the Dynamic Inverse Neural Network controller perform equally well at reconfiguration, but with less rate requirements from the actuators. Also presented are the pilot ratings for each controller for various failure scenarios and two samples of the required control actuation during reconfiguration. Finally, the paper concludes by stepping through the Generalized Predictive Control's reconfiguration process for an elevator failure.
Four-point bending as a method for quantitatively evaluating spinal arthrodesis in a rat model.
Robinson, Samuel T; Svet, Mark T; Kanim, Linda A; Metzger, Melodie F
2015-02-01
The most common method of evaluating the success (or failure) of rat spinal fusion procedures is manual palpation testing. Whereas manual palpation provides only a subjective binary answer (fused or not fused) regarding the success of a fusion surgery, mechanical testing can provide more quantitative data by assessing variations in strength among treatment groups. We here describe a mechanical testing method to quantitatively assess single-level spinal fusion in a rat model, to improve on the binary and subjective nature of manual palpation as an end point for fusion-related studies. We tested explanted lumbar segments from Sprague-Dawley rat spines after single-level posterolateral fusion procedures at L4-L5. Segments were classified as 'not fused,' 'restricted motion,' or 'fused' by using manual palpation testing. After thorough dissection and potting of the spine, 4-point bending in flexion then was applied to the L4-L5 motion segment, and stiffness was measured as the slope of the moment-displacement curve. Results demonstrated statistically significant differences in stiffness among all groups, which were consistent with preliminary grading according to manual palpation. In addition, the 4-point bending results provided quantitative information regarding the quality of the bony union formed and therefore enabled the comparison of fused specimens. Our results demonstrate that 4-point bending is a simple, reliable, and effective way to describe and compare results among rat spines after fusion surgery.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-01
... Friday, except Federal holidays. The AD docket contains this proposed AD, the regulatory evaluation, any... three criteria address the failure types under evaluation: single failures, single failures in... evaluations included consideration of previous actions taken that may mitigate the need for further action...
Liu, Wenbin; Liu, Aimin
2018-01-01
With the exploitation of offshore oil and gas gradually moving to deep water, higher temperature differences and pressure differences are applied to the pipeline system, making the global buckling of the pipeline more serious. For unburied deep-water pipelines, the lateral buckling is the major buckling form. The initial imperfections widely exist in the pipeline system due to manufacture defects or the influence of uneven seabed, and the distribution and geometry features of initial imperfections are random. They can be divided into two kinds based on shape: single-arch imperfections and double-arch imperfections. This paper analyzed the global buckling process of a pipeline with 2 initial imperfections by using a numerical simulation method and revealed how the ratio of the initial imperfection’s space length to the imperfection’s wavelength and the combination of imperfections affects the buckling process. The results show that a pipeline with 2 initial imperfections may suffer the superposition of global buckling. The growth ratios of buckling displacement, axial force and bending moment in the superposition zone are several times larger than no buckling superposition pipeline. The ratio of the initial imperfection’s space length to the imperfection’s wavelength decides whether a pipeline suffers buckling superposition. The potential failure point of pipeline exhibiting buckling superposition is as same as the no buckling superposition pipeline, but the failure risk of pipeline exhibiting buckling superposition is much higher. The shape and direction of two nearby imperfections also affects the failure risk of pipeline exhibiting global buckling superposition. The failure risk of pipeline with two double-arch imperfections is higher than pipeline with two single-arch imperfections. PMID:29554123
Palliative Care in Heart Failure: The PAL-HF Randomized, Controlled Clinical Trial.
Rogers, Joseph G; Patel, Chetan B; Mentz, Robert J; Granger, Bradi B; Steinhauser, Karen E; Fiuzat, Mona; Adams, Patricia A; Speck, Adam; Johnson, Kimberly S; Krishnamoorthy, Arun; Yang, Hongqiu; Anstrom, Kevin J; Dodson, Gwen C; Taylor, Donald H; Kirchner, Jerry L; Mark, Daniel B; O'Connor, Christopher M; Tulsky, James A
2017-07-18
Advanced heart failure (HF) is characterized by high morbidity and mortality. Conventional therapy may not sufficiently reduce patient suffering and maximize quality of life. The authors investigated whether an interdisciplinary palliative care intervention in addition to evidence-based HF care improves certain outcomes. The authors randomized 150 patients with advanced HF between August 15, 2012, and June 25, 2015, to usual care (UC) (n = 75) or UC plus a palliative care intervention (UC + PAL) (n = 75) at a single center. Primary endpoints were 2 quality-of-life measurements, the Kansas City Cardiomyopathy Questionnaire (KCCQ) overall summary and the Functional Assessment of Chronic Illness Therapy-Palliative Care scale (FACIT-Pal), assessed at 6 months. Secondary endpoints included assessments of depression and anxiety (measured via the Hospital Anxiety and Depression Scale [HADS]), spiritual well-being (measured via the FACIT-Spiritual Well-Being scale [FACIT-Sp]), hospitalizations, and mortality. Patients randomized to UC + PAL versus UC alone had clinically significant incremental improvement in KCCQ and FACIT-Pal scores from randomization to 6 months (KCCQ difference = 9.49 points, 95% confidence interval [CI]: 0.94 to 18.05, p = 0.030; FACIT-Pal difference = 11.77 points, 95% CI: 0.84 to 22.71, p = 0.035). Depression improved in UC + PAL patients (HADS-depression difference = -1.94 points; p = 0.020) versus UC-alone patients, with similar findings for anxiety (HADS-anxiety difference = -1.83 points; p = 0.048). Spiritual well-being was improved in UC + PAL versus UC-alone patients (FACIT-Sp difference = 3.98 points; p = 0.027). Randomization to UC + PAL did not affect rehospitalization or mortality. An interdisciplinary palliative care intervention in advanced HF patients showed consistently greater benefits in quality of life, anxiety, depression, and spiritual well-being compared with UC alone. (Palliative Care in Heart Failure [PAL-HF]; NCT01589601). Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Failure Predictions of Out-of-Autoclave Sandwich Joints with Delaminations under Flexure Loads
NASA Technical Reports Server (NTRS)
Nordendale, Nikolas; Goyal, Vinay; Lundgren, Eric; Patel, Dhruv; Farrokh, Babak; Jones, Justin; Fischetti, Grace; Segal, Kenneth
2015-01-01
An analysis and a test program was conducted to investigate the damage tolerance of composite sandwich joints. The joints contained a single circular delamination between the face-sheet and the doubler. The coupons were fabricated through out-of-autoclave (OOA) processes, a technology NASA is investigating for joining large composite sections. The four-point bend flexure test was used to induce compression loading into the side of the joint where the delamination was placed. The compression side was chosen since it tends to be one of the most critical loads in launch vehicles. Autoclave cure was used to manufacture the composite sandwich sections, while the doubler was co-bonded onto the sandwich face-sheet using an OOA process after sandwich panels were cured. A building block approach was adopted to characterize the mechanical properties of the joint material, including the fracture toughness between the doubler and facesheet. Twelve four-point-bend samples were tested, six in the sandwich core ribbon orientation and six in sandwich core cross-ribbon direction. Analysis predicted failure initiation and propagation at the pre-delaminated location, consistent with experimental observations. A building block approach using fracture analyses methods predicted failure loads in close agreement with tests. This investigation demonstrated a small strength reduction due to a flaw of significant size compared to the width of the sample. Therefore, concerns of bonding an OOA material to an in-autoclave material was mitigated for the geometries, materials, and load configurations considered.
Failure Predictions of Out-of-Autoclave Sandwich Joints with Delaminations Under Flexure Loads
NASA Technical Reports Server (NTRS)
Nordendale, Nikolas A.; Goyal, Vinay K.; Lundgren, Eric C.; Patel, Dhruv N.; Farrokh, Babak; Jones, Justin; Fischetti, Grace; Segal, Kenneth N.
2015-01-01
An analysis and a test program was conducted to investigate the damage tolerance of composite sandwich joints. The joints contained a single circular delamination between the face-sheet and the doubler. The coupons were fabricated through out-of-autoclave (OOA) processes, a technology NASA is investigating for joining large composite sections. The four-point bend flexure test was used to induce compression loading into the side of the joint where the delamination was placed. The compression side was chosen since it tends to be one of the most critical loads in launch vehicles. Autoclave cure was used to manufacture the composite sandwich sections, while the doubler was co-bonded onto the sandwich face-sheet using an OOA process after sandwich panels were cured. A building block approach was adopted to characterize the mechanical properties of the joint material, including the fracture toughness between the doubler and face-sheet. Twelve four-point-bend samples were tested, six in the sandwich core ribbon orientation and six in sandwich core cross-ribbon direction. Analysis predicted failure initiation and propagation at the pre-delaminated location, consistent with experimental observations. A building block approach using fracture analyses methods predicted failure loads in close agreement with tests. This investigation demonstrated a small strength reduction due to a flaw of significant size compared to the width of the sample. Therefore, concerns of bonding an OOA material to an in-autoclave material was mitigated for the geometries, materials, and load configurations considered.
Failure Predictions of Out-of-Autoclave Sandwich Joints with Delaminations Under Flexure Loads
NASA Technical Reports Server (NTRS)
Nordendale, Nikolas; Goyal, Vinay; Lundgren, Eric; Patel, Dhruv; Farrokh, Babak; Jones, Justin; Fischetti, Grace; Segal, Kenneth
2015-01-01
An analysis and a test program was conducted to investigate the damage tolerance of composite sandwich joints. The joints contained a single circular delamination between the face-sheet and the doubler. The coupons were fabricated through out-of-autoclave (OOA) processes, a technology NASA is investigating for joining large composite sections. The four-point bend flexure test was used to induce compression loading into the side of the joint where the delamination was placed. The compression side was chosen since it tends to be one of the most critical loads in launch vehicles. Autoclave cure was used to manufacture the composite sandwich sections, while the doubler was co-bonded onto the sandwich face-sheet using an OOA process after sandwich panels were cured. A building block approach was adopted to characterize the mechanical properties of the joint material, including the fracture toughness between the doubler and face-sheet. Twelve four-point-bend samples were tested, six in the sandwich core ribbon orientation and six in sandwich core cross-ribbon direction. Analysis predicted failure initiation and propagation at the pre-delaminated location, consistent with experimental observations. Fracture analyses methods predicted failure loads in close agreement with tests. This investigation demonstrated a strength reduction of 10 percent due to a flaw of significant size compared to the width of the sample. Therefore, concerns of bonding an OOA material to an in-autoclave material was mitigated for the geometries, materials, and load configurations considered.
Single wheel hub motor failures and their impact on vehicle and driver behaviour
NASA Astrophysics Data System (ADS)
Wanner, Daniel; Kreußlein, Maria; Augusto, Bruno; Drugge, Lars; Stensson Trigell, Annika
2016-10-01
This research work studies the impact of single wheel hub motor failures on the dynamic behaviour of electric vehicles and the corresponding driver reactions. An experimental study in a moving-base driving simulator is conducted to analyse the influence of single wheel hub motor failures for motorway speeds. Driver reaction times are derived from the measured data and discussed in their experimental context. The failure is rated objectively on the dynamic behaviour of the vehicle and compared to the subjective evaluation. Findings indicate that critical traffic situations impairing traffic safety can occur for motorway speeds. Clear counteractions by the drivers had to be taken.
Review on failure prediction techniques of composite single lap joint
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ab Ghani, A.F., E-mail: ahmadfuad@utem.edu.my; Rivai, Ahmad, E-mail: ahmadrivai@utem.edu.my
2016-03-29
Adhesive bonding is the most appropriate joining method in construction of composite structures. The use of reliable design and prediction technique will produce better performance of bonded joints. Several papers from recent papers and journals have been reviewed and synthesized to understand the current state of the art in this area. It is done by studying the most relevant analytical solutions for composite adherends with start of reviewing the most fundamental ones involving beam/plate theory. It is then extended to review single lap joint non linearity and failure prediction and finally on the failure prediction on composite single lap joint.more » The review also encompasses the finite element modelling part as tool to predict the elastic response of composite single lap joint and failure prediction numerically.« less
Buchhorn, G. H.; Gilbert, F.; Spahn, G.; Schultz, W.; Klinger, H.-M.
2010-01-01
Aim This experimental study aimed to compare the load-to-failure rate and stiffness of single- versus double-row suture techniques for repairing rotator cuff lesions using two different suture materials. Additionally, the mode of failure of each repair was evaluated. Method In 32 sheep shoulders, a standardized tear of the infraspinatus tendon was created. Then, n = 8 specimen were randomized to four repair methods: (1) Double-row Anchor Ethibond® coupled with polyester sutures, USP No. 2; (2) Double-Row Anchor HiFi® with polyblend polyethylene sutures, USP No. 2; (3) Single-Row Anchor Ethibond® coupled with braided polyester sutures, USP No. 2; and (4) Single-Row Anchor HiFi® with braided polyblend polyethylene sutures, USP No. 2. Arthroscopic Mason–Allen stitches were placed (single-row) and combined with medial horizontal mattress stitches (double-row). All specimens were loaded to failure at a constant displacement rate on a material testing machine. Results Group 4 showed lowest load-to-failure result with 155.7 ± 31.1 N compared to group 1 (293.4 ± 16.1 N) and group 2 (397.7 ± 7.4 N) (P < 0.001). Stiffness was highest in group 2 (162 ± 7.3 N/mm) and lowest in group 4 (84.4 ± 19.9 mm) (P < 0.001). In group 4, the main cause of failure was due to the suture cutting through the tendon (n = 6), a failure case observed in only n = 1 specimen in group 2 (P < 0.001). Conclusions A double-row technique combined with arthroscopic Mason-Allen/horizontal mattress stitches provides high initial failure strength and may minimize the risk of the polyethylene sutures cutting through the tendon in rotator cuff repair when a single load force is used. PMID:20049605
Yamada, Yoshiya; Katsoulakis, Evangelia; Laufer, Ilya; Lovelock, Michael; Barzilai, Ori; McLaughlin, Lily A; Zhang, Zhigang; Schmitt, Adam M; Higginson, Daniel S; Lis, Eric; Zelefsky, Michael J; Mechalakos, James; Bilsky, Mark H
2017-01-01
OBJECTIVE An analysis of factors contributing to durable radiographic control of spinal metastases was undertaken, drawing from a large single-institution database in an attempt to elucidate indications and dose requirements for successful treatment. METHODS All patients treated at a single institution with stereotactic radiosurgery (SRS) of the spine as first-line therapy were assessed for local progression of the treated site, defined as radiographic enlargement of the treated tumor and/or biopsy-proven evidence of active tumor cells. All patients were followed with CT, PET, or MR imaging every 3-6 months until death. Treatment decisions were made by a multidisciplinary team of radiation oncologists, neurosurgeons, and neuroradiologists. Target volumes were defined according to the international consensus guidelines and were reviewed in a multidisciplinary conference. Image-guided techniques and intensity modulation were used for every case. The tumor's histological type, gross tumor volume (GTV), dose that covers 95% of the GTV (GTV D95), percentage of GTV covered by 95% of the prescribed dose (GTV V95), planning target volume (PTV), dose that covers 95% of the PTV (PTV D95), and percentage of PTV covered by 95% of the prescribed dose (PTV V95) were analyzed for significance in relation to local control, based on time to local progression. RESULTS A total of 811 lesions were treated in 657 patients between 2003 and 2015 at a single institution. The mean follow-up and overall survival for the entire cohort was 26.9 months (range 2-141 months). A total of 28 lesions progressed and the mean time to failure was 26 months (range 9.7-57 months). The median prescribed dose was 2400 cGy (range 1600-2600 cGy). Both GTV D95 and PTV D95 were highly significantly associated with local failure in univariate analysis, but GTV and PTV and histological type did not reach statistical significance. The median GTV D95 for the cohort equal to or above the GTV D95 1830 cGy cut point (high dose) was 2356 cGy, and it was 1709 cGy for the cohort of patients who received less than 1830 cGy (low dose). In terms of PTV D95, the median dose for those equal to or above the cut point of 1740 cGy (high dose) was 2233 cGy, versus 1644 cGy for those lesions below the PTV D95 cut point of 1740 cGy (low dose). CONCLUSIONS High-dose single-session SRS provides durable long-term control, regardless of the histological findings or tumor size. In this analysis, the only significant factors predictive of local control were related to the actual dose of radiation given. Although the target volumes were well treated with the intended dose, those lesions irradiated to higher doses (median GTV D95 2356 cGy, minimum 1830 cGy) had a significantly higher probability of durable local control than those treated with lower doses (median PTV D95 2232 cGy, minimum of 1740 cGy) (p < 0.001). Patients in the high-dose cohort had a 2% cumulative rate of local failure. Histological findings were not associated with local failure, suggesting that radioresistant histological types benefit in particular from radiosurgery. For patients with a favorable prognosis, a higher dose of SRS is important for long-term outcomes.
Yamada, Yoshiya; Katsoulakis, Evangelia; Laufer, Ilya; Lovelock, Michael; Barzilai, Ori; McLaughlin, Lily A.; Zhang, Zhigang; Schmitt, Adam M.; Higginson, Daniel S.; Lis, Eric; Zelefsky, Michael J.; Mechalakos, James; Bilsky, Mark H.
2017-01-01
Objective An analysis of factors contributing to durable radiographic control of spinal metastases was undertaken, drawing from a large single-institution database in an attempt to elucidate indications and dose requirements for successful treatment. Methods All patients treated at a single institution with stereotactic radiosurgery (SRS) of the spine as first-line therapy were assessed for local progression of the treated site, defined as radiographic enlargement of the treated tumor and/or biopsy-proven evidence of active tumor cells. All patients were followed with CT, PET, or MR imaging every 3–6 months until death. Treatment decisions were made by a multidisciplinary team of radiation oncologists, neurosurgeons, and neuroradiologists. Target volumes were defined according to the international consensus guidelines and were reviewed in a multidisciplinary conference. Image-guided techniques and intensity modulation were used for every case. The tumor’s histological type, gross tumor volume (GTV), dose that covers 95% of the GTV (GTV D95), percentage of GTV covered by 95% of the prescribed dose (GTV V95), planning target volume (PTV), dose that covers 95% of the PTV (PTV D95), and percentage of PTV covered by 95% of the prescribed dose (PTV V95) were analyzed for significance in relation to local control, based on time to local progression. Results A total of 811 lesions were treated in 657 patients between 2003 and 2015 at a single institution. The mean follow-up and overall survival for the entire cohort was 26.9 months (range 2–141 months). A total of 28 lesions progressed and the mean time to failure was 26 months (range 9.7–57 months). The median prescribed dose was 2400 cGy (range 1600–2600 cGy). Both GTV D95 and PTV D95 were highly significantly associated with local failure in univariate analysis, but GTV and PTV and histological type did not reach statistical significance. The median GTV D95 for the cohort equal to or above the GTV D95 1830 cGy cut point (high dose) was 2356 cGy, and it was 1709 cGy for the cohort of patients who received less than 1830 cGy (low dose). In terms of PTV D95, the median dose for those equal to or above the cut point of 1740 cGy (high dose) was 2233 cGy, versus 1644 cGy for those lesions below the PTV D95 cut point of 1740 cGy (low dose). Conclusions High-dose single-session SRS provides durable long-term control, regardless of the histological findings or tumor size. In this analysis, the only significant factors predictive of local control were related to the actual dose of radiation given. Although the target volumes were well treated with the intended dose, those lesions irradiated to higher doses (median GTV D95 2356 cGy, minimum 1830 cGy) had a significantly higher probability of durable local control than those treated with lower doses (median PTV D95 2232 cGy, minimum of 1740 cGy) (p < 0.001). Patients in the high-dose cohort had a 2% cumulative rate of local failure. Histological findings were not associated with local failure, suggesting that radioresistant histological types benefit in particular from radiosurgery. For patients with a favorable prognosis, a higher dose of SRS is important for long-term outcomes. PMID:28041329
NASA Astrophysics Data System (ADS)
Kerr-Anderson, Eric
Structural composite laminates were ballistically impacted while under in-plane compressive pre-stress. Residual properties, damage characterization, and energy absorption were compared to determine synergistic effects of in-plane compressive pre-stress and impact velocity. A fixture was developed to apply in-plane compressive loads up to 30 tons to structural composites during an impact event using a single-stage light-gas gun. Observed failure modes included typical conical delamination, the development of an impact initiated shear crack (IISC), and the shear failure of a pre-stressed composite due to impact. It was observed that the compressive failure threshold quadratically decreased in relation to the impact velocity up to velocities that caused partial penetration. For all laminates impacted at velocities causing partial or full penetration up to 350 ms-1, the failure threshold was consistent and used as an experimental normalization. Samples impacted below 65% of the failure threshold witnessed no significant change in damage morphology or residual properties when compared to typical conical delamination. Samples impacted above 65% of the failure threshold witnessed additional damage in the form of a shear crack extending perpendicular to the applied load from the point of impact. The presence of an IISC reduced the residual properties and even caused failure upon impact at extreme combinations. Four failure envelopes have been established as: transient failure, steady state failure, impact initiated shear crack, and conical damage. Boundaries and empirically based equations for residual compressive strength have been developed for each envelope with relation to two E-glass/vinyl ester laminate systems. Many aspects of pre-stressed impact have been individually examined, but there have been no comprehensive examinations of pre-stressed impact. This research has resulted in the exploration and characterization of compressively pre-stressed damage for impact velocities resulting in reflection, partial penetration, and penetration at pre-stress levels resulting in conical damage, shear cracking, and failure.
Quek, H C; Tan, Keson B; Nicholls, Jack I
2008-01-01
Biomechanical load-fatigue performance data on single-tooth implant systems with different implant-abutment interface designs is lacking in the literature. This study evaluated the load fatigue performance of 4 implant-abutment interface designs (Brånemark-CeraOne; 3i Osseotite-STA abutment; Replace Select-Easy abutment; and Lifecore Stage-1-COC abutment system). The number of load cycles to fatigue failure of 4 implant-abutment designs was tested with a custom rotational load fatigue machine. The effect of increasing and decreasing the tightening torque by 20% respectively on the load fatigue performance was also investigated. Three different tightening torque levels (recommended torque, -20% recommended torque, +20% recommended torque) were applied to the 4 implant systems. There were 12 test groups with 5 samples in each group. The rotational load fatigue machine subjected specimens to a sinusoidally applied 35 Ncm bending moment at a test frequency of 14 Hz. The number of cycles to failure was recorded. A cutoff of 5 x 10(6) cycles was applied as an upper limit. There were 2 implant failures and 1 abutment screw failure in the Brånemark group. Five abutment screw failures and 4 implant failures was recorded for the 3i system. The Replace Select system had 1 implant failure. Five cone screw failures were noted for the Lifecore system. Analysis of variance revealed no statistically significant difference in load cycles to failure for the 4 different implant-abutment systems torqued at recommended torque level. A statistically significant difference was found between the -20% torque group and the +20% torque group (P < .05) for the 3i system. Load fatigue performance and failure location is system specific and related to the design characteristics of the implant-abutment combination. It appeared that if the implant-abutment interface was maintained, load fatigue failure would occur at the weakest point of the implant. It is important to use the torque level recommended by the manufacturer.
Local strain and damage mapping in single trabeculae during three-point bending tests
Jungmann, R.; Szabo, M.E.; Schitter, G.; Tang, Raymond Yue-Sing; Vashishth, D.; Hansma, P.K.; Thurner, P.J.
2012-01-01
The use of bone mineral density as a surrogate to diagnose bone fracture risk in individuals is of limited value. However, there is growing evidence that information on trabecular microarchitecture can improve the assessment of fracture risk. One current strategy is to exploit finite element analysis (FEA) applied to 3D image data of several mm-sized trabecular bone structures obtained from non-invasive imaging modalities for the prediction of apparent mechanical properties. However, there is a lack of FE damage models, based on solid experimental facts, which are needed to validate such approaches and to provide criteria marking elastic–plastic deformation transitions as well as microdamage initiation and accumulation. In this communication, we present a strategy that could elegantly lead to future damage models for FEA: direct measurements of local strains involved in microdamage initiation and plastic deformation in single trabeculae. We use digital image correlation to link stress whitening in bone, reported to be correlated to microdamage, to quantitative local strain values. Our results show that the whitening zones, i.e. damage formation, in the presented loading case of a three-point bending test correlate best with areas of elevated tensile strains oriented parallel to the long axis of the samples. The average local strains along this axis were determined to be (1.6 ± 0.9)% at whitening onset and (12 ± 4)% just prior to failure. Overall, our data suggest that damage initiation in trabecular bone is asymmetric in tension and compression, with failure originating and propagating over a large range of tensile strains. PMID:21396601
Scirica, Benjamin M; Braunwald, Eugene; Raz, Itamar; Cavender, Matthew A; Morrow, David A; Jarolim, Petr; Udell, Jacob A; Mosenzon, Ofri; Im, KyungAh; Umez-Eronini, Amarachi A; Pollack, Pia S; Hirshberg, Boaz; Frederich, Robert; Lewis, Basil S; McGuire, Darren K; Davidson, Jaime; Steg, Ph Gabriel; Bhatt, Deepak L
2014-10-28
Diabetes mellitus and heart failure frequently coexist. However, few diabetes mellitus trials have prospectively evaluated and adjudicated heart failure as an end point. A total of 16 492 patients with type 2 diabetes mellitus and a history of, or at risk of, cardiovascular events were randomized to saxagliptin or placebo (mean follow-up, 2.1 years). The primary end point was the composite of cardiovascular death, myocardial infarction, or ischemic stroke. Hospitalization for heart failure was a predefined component of the secondary end point. Baseline N-terminal pro B-type natriuretic peptide was measured in 12 301 patients. More patients treated with saxagliptin (289, 3.5%) were hospitalized for heart failure compared with placebo (228, 2.8%; hazard ratio, 1.27; 95% confidence intercal, 1.07-1.51; P=0.007). Corresponding rates at 12 months were 1.9% versus 1.3% (hazard ratio, 1.46; 95% confidence interval, 1.15-1.88; P=0.002), with no significant difference thereafter (time-varying interaction, P=0.017). Subjects at greatest risk of hospitalization for heart failure had previous heart failure, an estimated glomerular filtration rate ≤60 mL/min, or elevated baseline levels of N-terminal pro B-type natriuretic peptide. There was no evidence of heterogeneity between N-terminal pro B-type natriuretic peptide and saxagliptin (P for interaction=0.46), although the absolute risk excess for heart failure with saxagliptin was greatest in the highest N-terminal pro B-type natriuretic peptide quartile (2.1%). Even in patients at high risk of hospitalization for heart failure, the risk of the primary and secondary end points were similar between treatment groups. In the context of balanced primary and secondary end points, saxagliptin treatment was associated with an increased risk or hospitalization for heart failure. This increase in risk was highest among patients with elevated levels of natriuretic peptides, previous heart failure, or chronic kidney disease. http://www.clinicaltrials.gov. Unique identifier: NCT01107886. © 2014 American Heart Association, Inc.
Cognitive impairment in heart failure patients
Leto, Laura; Feola, Mauro
2014-01-01
Cognitive damage in heart failure (HF) involves different domains thus interfering with the ability for single patient to self-care and to cope with treatment regimens, modifying symptoms and health behaviours. Many cerebral and functional changes were detected in brain imaging, involving areas of both grey and white matter deputed to cognition. Although various instruments are available to explore cognition, no consensus was obtained on better tools to be used in HF population. Reduction in cerebral blood flow, decreased cardiac output, alterations of cerebrovascular reactivity and modification of blood pressure levels are the main features involved in the etiopathogenetic mechanisms of cognitive deficit. Several cardiac variables, laboratory parameters, demographic and clinical elements were studied for their possible relation with cognition and should be properly evaluated to define patients at increased risk of impairment. The present review gathers available data pointing out assured information and discussing possible areas of research development. PMID:25593581
Destructive Single-Event Failures in Diodes
NASA Technical Reports Server (NTRS)
Casey, Megan C.; Gigliuto, Robert A.; Lauenstein, Jean-Marie; Wilcox, Edward P.; Kim, Hak; Chen, Dakai; Phan, Anthony M.; LaBel, Kenneth A.
2013-01-01
In this summary, we have shown that diodes are susceptible to destructive single-event effects, and that these failures occur along the guard ring. By determining the last passing voltages, a safe operating area can be derived. By derating off of those values, rather than by the rated voltage, like what is currently done with power MOSFETs, we can work to ensure the safety of future missions. However, there are still open questions about these failures. Are they limited to a single manufacturer, a small number, or all of them? Is there a threshold rated voltage that must be exceeded to see these failures? With future work, we hope to answer these questions. In the full paper, laser results will also be presented to verify that failures only occur along the guard ring.
Bacon, David J.; Tang, Doug; Salas, Carola; Roncal, Norma; Lucas, Carmen; Gerena, Lucia; Tapia, Lorena; Llanos-Cuentas, A. Alejandro; Garcia, Coralith; Solari, Lelv; Kyle, Dennis; Magill, Alan J.
2009-01-01
Background Sulfadoxine-pyrimethamine was a common first line drug therapy to treat uncomplicated falciparum malaria, but increasing therapeutic failures associated with the development of significant levels of resistance worldwide has prompted change to alternative treatment regimes in many national malaria control programs. Methodology and Finding We conducted an in vivo therapeutic efficacy trial of sulfadoxine-pyrimethamine at two locations in the Peruvian Amazon enrolling 99 patients of which, 86 patients completed the protocol specified 28 day follow up. Our objective was to correlate the presence of polymorphisms in P. falciparum dihydrofolate reductase and dihydropteroate synthase to in vitro parasite susceptibility to sulfadoxine and pyrimethamine and to in vivo treatment outcomes. Inhibitory concentration 50 values of isolates increased with numbers of mutations (single [108N], sextuplet [BR/51I/108N/164L and 437G/581G]) and septuplet (BR/51I/108N/164L and 437G/540E/581G) with geometric means of 76 nM (35–166 nM), 582 nM (49-6890- nM) and 4909 (3575–6741 nM) nM for sulfadoxine and 33 nM (22–51 nM), 81 nM (19–345 nM), and 215 nM (176–262 nM) for pyrimethamine. A single mutation present in the isolate obtained at the time of enrollment from either dihydrofolate reductase (164L) or dihydropteroate synthase (540E) predicted treatment failure as well as any other single gene alone or in combination. Patients with the dihydrofolate reductase 164L mutation were 3.6 times as likely to be treatment failures [failures 85.4% (164L) vs 23.7% (I164); relative risk = 3.61; 95% CI: 2.14 – 6.64] while patients with the dihydropteroate synthase 540E were 2.6 times as likely to fail treatment (96.7% (540E) vs 37.5% (K540); relative risk = 2.58; 95% CI: 1.88 – 3.73). Patients with both dihydrofolate reductase 164L and dihydropteroate synthase 540E mutations were 4.1 times as likely to be treatment failures [96.7% vs 23.7%; RR = 4.08; 95% CI: 2.45 – 7.46] compared to patients having both wild forms (I164 and K540). Conclusions In this part of the Amazon basin, it may be possible to predict treatment failure with sulfadoxine-pyrimethamine equally well by determination of either of the single mutations dihydrofolate reductase 164L or dihydropteroate synthase 540E. Trial Registration ClinicalTrials.gov NCT00951106 NCT00951106 PMID:19707564
Mechanical Properties of ZTO, ITO, and a-Si:H Multilayer Films for Flexible Thin Film Solar Cells.
Hengst, Claudia; Menzel, Siegfried B; Rane, Gayatri K; Smirnov, Vladimir; Wilken, Karen; Leszczynska, Barbara; Fischer, Dustin; Prager, Nicole
2017-03-01
The behavior of bi- and trilayer coating systems for flexible a-Si:H based solar cells consisting of a barrier, an electrode, and an absorption layer is studied under mechanical load. First, the film morphology, stress, Young's modulus, and crack onset strain (COS) were analyzed for single film coatings of various thickness on polyethylene terephthalate (PET) substrates. In order to demonstrate the role of the microstructure of a single film on the mechanical behavior of the whole multilayer coating, two sets of InSnOx (indium tin oxide, ITO) conductive coatings were prepared. Whereas a characteristic grain-subgrain structure was observed in ITO-1 films, grain growth was suppressed in ITO-2 films. ITO-1 bilayer coatings showed two-step failure under tensile load with cracks propagating along the ITO-1/a-Si:H-interface, whereas channeling cracks in comparable bi- and trilayers based on amorphous ITO-2 run through all constituent layers. A two-step failure is preferable from an application point of view, as it may lead to only a degradation of the performance instead of the ultimate failure of the device. Hence, the results demonstrate the importance of a fine-tuning of film microstructure not only for excellent electrical properties, but also for a high mechanical performance of flexible devices (e.g., a-Si:H based solar cells) during fabrication in a roll-to-roll process or under service.
NASA Astrophysics Data System (ADS)
Zhou, Jiang; D'Amore, Alberto; Yang, Yuming; He, Tianbai; Li, Binyao; Nicolais, Luigi
1994-05-01
Flexural fatigue tests were conducted on injection molded glass fiber reinforced a blend of polyphenylene ether ketone and polyphenylene sulfide composite using four-point bending with different stress ratios and different frequencies. The fatigue behavior of this material was described. The constructed S-N curves shift their trends obviously at the maximum cyclic stress being about 80% of the ultimate flexural strength. Examinations of failure surfaces for various loading conditions show that the fatigue failure mechanisms appear to be matrix yielding at high stresses and crack growth at low stresses. Analyses of the fatigue data at various stress ratios reveal that the data at low stress superimpose to form a single curve which is nearly linear when they are plotted as stress range versus number of cycles to failure in bilogarithmic axes, while the data at high stresses also converge to yield a single curve when they are plotted as ( S max S range)1/2 against specimen lifetimes ( S max is the maximum stress and S range is the stress range). These results show that for the studied material the main factor influencing the lifetime is the stress range at low stresses and the parameter ( S max S range)1/2 at high stresses. Comparison of fatigue data in the frequency range of 0.89 7.0 Hz was made, no significant effect of frequency on the fatigue behavior is found.
Mechanical Properties of ZTO, ITO, and a-Si:H Multilayer Films for Flexible Thin Film Solar Cells
Hengst, Claudia; Menzel, Siegfried B; Rane, Gayatri K; Smirnov, Vladimir; Wilken, Karen; Leszczynska, Barbara; Fischer, Dustin; Prager, Nicole
2017-01-01
The behavior of bi- and trilayer coating systems for flexible a-Si:H based solar cells consisting of a barrier, an electrode, and an absorption layer is studied under mechanical load. First, the film morphology, stress, Young’s modulus, and crack onset strain (COS) were analyzed for single film coatings of various thickness on polyethylene terephthalate (PET) substrates. In order to demonstrate the role of the microstructure of a single film on the mechanical behavior of the whole multilayer coating, two sets of InSnOx (indium tin oxide, ITO) conductive coatings were prepared. Whereas a characteristic grain–subgrain structure was observed in ITO-1 films, grain growth was suppressed in ITO-2 films. ITO-1 bilayer coatings showed two-step failure under tensile load with cracks propagating along the ITO-1/a-Si:H-interface, whereas channeling cracks in comparable bi- and trilayers based on amorphous ITO-2 run through all constituent layers. A two-step failure is preferable from an application point of view, as it may lead to only a degradation of the performance instead of the ultimate failure of the device. Hence, the results demonstrate the importance of a fine-tuning of film microstructure not only for excellent electrical properties, but also for a high mechanical performance of flexible devices (e.g., a-Si:H based solar cells) during fabrication in a roll-to-roll process or under service. PMID:28772609
The geomechanical strength of carbonate rock in Kinta valley, Ipoh, Perak Malaysia
NASA Astrophysics Data System (ADS)
Mazlan, Nur Amanina; Lai, Goh Thian; Razib, Ainul Mardhiyah Mohd; Rafek, Abdul Ghani; Serasa, Ailie Sofyiana; Simon, Norbert; Surip, Noraini; Ern, Lee Khai; Mohamed, Tuan Rusli
2018-04-01
The stability of both cut rocks and underground openings were influenced by the geomechanical strength of rock materials, while the strength characteristics are influenced by both material characteristics and the condition of weathering. This paper present a systematic approach to quantify the rock material strength characteristics for material failure and material & discontinuities failure by using uniaxial compressive strength, point load strength index and Brazilian tensile strength for carbonate rocks. Statistical analysis of the results at 95 percent confidence level showed that the mean value of compressive strength, point load strength index and Brazilian tensile strength for with material failure and material & discontinuities failure were 76.8 ± 4.5 and 41.2 ± 4.1 MPa with standard deviation of 15.2 and 6.5 MPa, respectively. The point load strength index for material failure and material & discontinuities failure were 3.1 ± 0.2 MPa and 1.8 ± 0.3 MPa with standard deviation of 0.9 and 0.6 MPa, respectively. The Brazilian tensile strength with material failure and material & discontinuities failure were 7.1 ± 0.3 MPa and 4.1 ± 0.3 MPa with standard deviation of 1.4 and 0.6 MPa, respectively. The results of this research revealed that the geomechanical strengths of rock material of carbonate rocks for material & discontinuities failure deteriorates approximately ½ from material failure.
Acute decompensated heart failure: new strategies for improving outcomes [digest].
Singer Fisher, Emily; Burns, Boyd; Kim, Jeremy
2017-05-22
Acute decompensated heart failure is a common emergency department presentation with significant associated morbidity and mortality. Heart failure accounts for more than 1 million hospitalizations annually, with a steadily increasing incidence as our population ages. This issue reviews recent literature regarding appropriate management of emergency department presentations of acute decompensated heart failure, with special attention to newer medication options. Emergency department management and appropriate interventions are discussed, along with critical decision-making points in resuscitation for both hypertensive and hypotensive patients. [Points & Pearls is a digest of Emergency Medicine Practice].
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peters, K.A.; Atkinson, P.F.; Hammond, E.C.,JR.
Reciprocity failure was examined for IIaO spectroscopic film. Three separate experiments were performed in order to study film batch variations, thermal and aging effects in relationship to reciprocity failure, and shifting of reciprocity failure points as a function of thermal and aging effects. The failure was examined over ranges of time between 5 and 60 seconds. The variation to illuminance was obtained by using thirty neutral density filters. A standard sensitometer device imprinted the wedge pattern on the film as exposure time was subjected to variation. The results indicate that film batch differences, temperature, and aging play an important rolemore » in reciprocity failure of IIaO spectroscopic film. A shifting of the failure points was also observed in various batches of film.« less
Paulsson, Anna K.; Holmes, Jordan A.; Peiffer, Ann M.; Miller, Lance D.; Liu, Wennuan; Xu, Jianfeng; Hinson, William H.; Lesser, Glenn J.; Laxton, Adrian W.; Tatter, Stephen B.; Debinski, Waldemar
2014-01-01
We investigate the differences in molecular signature and clinical outcomes between multiple lesion glioblastoma (GBM) and single focus GBM in the modern treatment era. Between August 2000 and May 2010, 161 patients with GBM were treated with modern radiotherapy techniques. Of this group, 33 were considered to have multiple lesion GBM (25 multifocal and 8 multicentric). Patterns of failure, time to progression and overall survival were compared based on whether the tumor was considered a single focus or multiple lesion GBM. Genomic groupings and methylation status were also investigated as a possible predictor of multifocality in a cohort of 41 patients with available tissue for analysis. There was no statistically significant difference in overall survival (p < 0.3) between the multiple lesion tumors (8.2 months) and single focus GBM (11 months). Progression free survival was superior in the single focus tumors (7.1 months) as compared to multi-focal (5.6 months, p = 0.02). For patients with single focus, multifocal and multicentric GBM, 81, 76 and 88 % of treatment failures occurred in the 60 Gy volume (p < 0.5), while 54, 72, and 38 % of treatment failures occurred in the 46 Gy volume (p < 0.4). Out of field failures were rare in both single focus and multiple foci GBM (7 vs 3 %). Genomic groupings and methylation status were not found to predict for multifocality. Patterns of failure, survival and genomic signatures for multiple lesion GBM do not appreciably differ when compared to single focus tumors. PMID:24990827
Failure analysis of a tool steel torque shaft
NASA Technical Reports Server (NTRS)
Reagan, J. R.
1981-01-01
A low design load drive shaft used to deliver power from an experimental exhaust heat recovery system to the crankshaft of an experimental diesel truck engine failed during highway testing. An independent testing laboratory analyzed the failure by routine metallography and attributed the failure to fatigue induced by a banded microstructure. Visual examination by NASA of the failed shaft plus the knowledge of the torsional load that it carried pointed to a 100 percent ductile failure with no evidence of fatigue. Scanning electron microscopy confirmed this. Torsional test specimens were produced from pieces of the failed shaft and torsional overload testing produced identical failures to that which had occurred in the truck engine. This pointed to a failure caused by a high overload and although the microstructure was defective it was not the cause of the failure.
NASA Technical Reports Server (NTRS)
Telesman, Jack; Kantzos, Peter
1988-01-01
An in situ fatigue loading stage inside a scanning electron microscope (SEM) was used to determine the fatigue crack growth behavior of a PWA 1480 single-crystal nickel-based superalloy. The loading stage permits real-time viewing of the fatigue damage processes at high magnification. The PWA 1480 single-crystal, single-edge notch specimens were tested with the load axis parallel to the (100) orientation. Two distinct fatigue failure mechanisms were identified. The crack growth rate differed substantially when the failure occurred on a single slip system in comparison to multislip system failure. Two processes by which crack branching is produced were identified and are discussed. Also discussed are the observed crack closure mechanisms.
Radiation Tests on 2Gb NAND Flash Memories
NASA Technical Reports Server (NTRS)
Nguyen, Duc N.; Guertin, Steven M.; Patterson, J. D.
2006-01-01
We report on SEE and TID tests of highly scaled Samsung 2Gbits flash memories. Both in-situ and biased interval irradiations were used to characterize the response of the total accumulated dose failures. The radiation-induced failures can be categorized as followings: single event upset (SEU) read errors in biased and unbiased modes, write errors, and single-event-functional-interrupt (SEFI) failures.
Failure rate of single dose methotrexate in managment of ectopic pregnancy.
Sendy, Feras; AlShehri, Eman; AlAjmi, Amani; Bamanie, Elham; Appani, Surekha; Shams, Taghreed
2015-01-01
Background. One of the treatment modalities for ectopic pregnancy is methotrexate. The purpose of this study is to identify the failure rate of methotrexate in treating patients with ectopic pregnancy as well as the risk factors leading to treatment failure. Methods. A retrospective chart review of 225 patients who received methotrexate as a primary management option for ectopic pregnancy. Failure of single dose of methotrexate was defined as drop of BHCG level less than or equal to 14% in the seventh day after administration of methotrexate. Results. 225 patients had methotrexate. Most of the patients (151 (67%)) received methotrexate based on the following formula: f 50 mg X body surface area. Single dose of methotrexate was successful in 72% (162/225) of the patients. 28% (63/225) were labeled as failure of single dose of methotrexate because of suboptimal drop in BhCG. 63% (40/63) of failure received a second dose of methotrexate, and 37% (23/63) underwent surgical treatment. Among patient who received initial dose of methotrexate, 71% had moderate or severe pain, and 58% had ectopic mass size of more than 4 cm on ultrasound. Conclusion. Liberal use of medical treatment of ectopic pregnancy results in 71% success rate.
Observations of Single Event Failure in Power MOSFETS
NASA Technical Reports Server (NTRS)
Nichols, D.; McCarty, K.; Coss, J.
1994-01-01
The first compendium of single event test data for power MOSFETs provides failure thresholds from burnout or gate rupture for over 100 devices of eight manufacturers. Ordering the data has also provided some useful insights.
Craig, Darren G N; Bates, Caroline M; Davidson, Janice S; Martin, Kirsty G; Hayes, Peter C; Simpson, Kenneth J
2012-01-01
AIMS Paracetamol (acetaminophen) poisoning remains the major cause of severe acute hepatotoxicity in the UK. In this large single centre cohort study we examined the clinical impact of staggered overdoses and delayed presentation following paracetamol overdose. RESULTS Between 1992 and 2008, 663 patients were admitted with paracetamol-induced severe liver injury, of whom 161 (24.3%) had taken a staggered overdose. Staggered overdose patients were significantly older and more likely to abuse alcohol than single time point overdose patients. Relief of pain (58.2%) was the commonest rationale for repeated supratherapeutic ingestion. Despite lower total ingested paracetamol doses and lower admission serum alanine aminotransferase concentrations, staggered overdose patients were more likely to be encephalopathic on admission, require renal replacement therapy or mechanical ventilation and had higher mortality rates compared with single time point overdoses (37.3% vs. 27.8%, P = 0.025), although this overdose pattern did not independently predict death. The King's College poor prognostic criteria had reduced sensitivity (77.6, 95% CI 70.8, 81.5) for this pattern of overdose. Of the 396/450 (88.0%) single time point overdoses in whom accurate timings could be obtained, 178 (44.9%) presented to medical services >24 h following overdose. Delayed presentation beyond 24 h post overdose was independently associated with death/liver transplantation (OR 2.25, 95% CI 1.23, 4.12, P = 0.009). CONCLUSIONS Both delayed presentation and staggered overdose pattern are associated with adverse outcomes following paracetamol overdose. These patients are at increased risk of developing multi-organ failure and should be considered for early transfer to specialist liver centres. PMID:22106945
A first packet processing subdomain cluster model based on SDN
NASA Astrophysics Data System (ADS)
Chen, Mingyong; Wu, Weimin
2017-08-01
For the current controller cluster packet processing performance bottlenecks and controller downtime problems. An SDN controller is proposed to allocate the priority of each device in the SDN (Software Defined Network) network, and the domain contains several network devices and Controller, the controller is responsible for managing the network equipment within the domain, the switch performs data delivery based on the load of the controller, processing network equipment data. The experimental results show that the model can effectively solve the risk of single point failure of the controller, and can solve the performance bottleneck of the first packet processing.
Biomechanical Analysis of Suture Anchor vs Tenodesis Screw for FHL Transfer.
Drakos, Mark C; Gott, Michael; Karnovsky, Sydney C; Murphy, Conor I; DeSandis, Bridget A; Chinitz, Noah; Grande, Daniel; Chahine, Nadeen
2017-07-01
Chronic Achilles injury is often treated with flexor hallucis longus (FHL) tendon transfer to the calcaneus using 1 or 2 incisions. A single incision avoids the risks of extended dissections yet yields smaller grafts, which may limit fixation options. We investigated the required length of FHL autograft and biomechanical profiles for suture anchor and biotenodesis screw fixation. Single-incision FHL transfer with suture anchor or biotenodesis screw fixation to the calcaneus was performed on 20 fresh cadaveric specimens. Specimens were cyclically loaded until maximal load to failure. Length of FHL tendon harvest, ultimate load, stiffness, and mode of failure were recorded. Tendon harvest length needed for suture anchor fixation was 16.8 ± 2.1 mm vs 29.6 ± 2.4 mm for biotenodesis screw ( P = .002). Ultimate load to failure was not significantly different between groups. A significant inverse correlation existed between failure load and donor age when all specimens were pooled (ρ = -0.49, P < .05). Screws in younger specimens (fewer than 70) resulted in significantly greater failure loads ( P < .03). No difference in stiffness was found between groups. Modes of failure for screw fixation were either tunnel pullout (n = 6) or tendon rupture (n = 4). Anchor failure occurred mostly by suture breakage (n = 8). Adequate FHL tendon length could be harvested through a single posterior incision for fixation to the calcaneus with either fixation option, but suture anchor required significantly less graft length. Stiffness, fixation strength, and load to failure were comparable between groups. An inverse correlation existed between failure load and donor age. Younger specimens with screw fixation demonstrated significantly greater failure loads. Adequate harvest length for FHL transfer could be achieved with a single posterior incision. There was no difference in strength of fixation between suture anchor and biotenodesis screw.
Destructive Single-Event Failures in Schottky Diodes
NASA Technical Reports Server (NTRS)
Casey, Megan C.; Lauenstein, Jean-Marie; Gigliuto, Robert A.; Wilcox, Edward P.; Phan, Anthony M.; Kim, Hak; Chen, Dakai; LaBel, Kenneth A.
2014-01-01
This presentation contains test results for destructive failures in DC-DC converters. We have shown that Schottky diodes are susceptible to destructive single-event effects. Future work will be completed to identify parameter that determines diode susceptibility.
Heart failure: not a single organ disease but a multisystem syndrome.
Warriner, David; Sheridan, Paul; Lawford, Patricia
2015-06-01
Heart failure is not simply a single organ disease; rather it is a complex multi-system clinical syndrome, with impairment of endocrine, haematological, musculoskeletal, renal, respiratory and vascular systems, which influence morbidity and mortality.
Meisel, Adam F; Henninger, Heath B; Barber, F Alan; Getelman, Mark H
2017-05-01
The purpose of this study was to evaluate the time zero cyclic and failure loading properties of a linked single-row rotator cuff repair compared with a standard simple suture single-row repair using triple-loaded suture anchors. Eighteen human cadaveric shoulders from 9 matched pairs were dissected, and full-thickness supraspinatus tears were created. The tendon cross-sectional area was recorded. In each pair, one side was repaired with a linked single-row construct and the other with a simple suture single-row construct, both using 2 triple-loaded suture anchors. After preloading, specimens were cycled to 1 MPa of effective stress at 1 Hz for 500 cycles, and gap formation was recorded with a digital video system. Samples were then loaded to failure, and modes of failure were recorded. There was no statistical difference in peak gap formation between the control and linked constructs (3.6 ± 0.9 mm and 3.6 ± 1.2 mm, respectively; P = .697). Both constructs averaged below a 5-mm cyclic failure threshold. There was no statistical difference in ultimate load to failure between the control and linked repair (511.1 ± 139.0 N and 561.2 ± 131.8 N, respectively; P = .164), and both groups reached failure at loads similar to previous studies. Constructs failed predominantly via tissue tearing parallel to the medial suture line. The linked repair performed similarly to the simple single-row repair. Both constructs demonstrated high ultimate load to failure and good resistance to gap formation with cyclic loading, validating the time zero strength of both constructs in a human cadaveric model. The linked repair provided equivalent resistance to gap formation and failure loads compared with simple suture single-row repairs with triple-loaded suture anchors. This suggests that the linked repair is a simplified rip-stop configuration using the existing suture that may perform similarly to current rotator cuff repair techniques. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Size distributions and failure initiation of submarine and subaerial landslides
ten Brink, Uri S.; Barkan, R.; Andrews, B.D.; Chaytor, J.D.
2009-01-01
Landslides are often viewed together with other natural hazards, such as earthquakes and fires, as phenomena whose size distribution obeys an inverse power law. Inverse power law distributions are the result of additive avalanche processes, in which the final size cannot be predicted at the onset of the disturbance. Volume and area distributions of submarine landslides along the U.S. Atlantic continental slope follow a lognormal distribution and not an inverse power law. Using Monte Carlo simulations, we generated area distributions of submarine landslides that show a characteristic size and with few smaller and larger areas, which can be described well by a lognormal distribution. To generate these distributions we assumed that the area of slope failure depends on earthquake magnitude, i.e., that failure occurs simultaneously over the area affected by horizontal ground shaking, and does not cascade from nucleating points. Furthermore, the downslope movement of displaced sediments does not entrain significant amounts of additional material. Our simulations fit well the area distribution of landslide sources along the Atlantic continental margin, if we assume that the slope has been subjected to earthquakes of magnitude ??? 6.3. Regions of submarine landslides, whose area distributions obey inverse power laws, may be controlled by different generation mechanisms, such as the gradual development of fractures in the headwalls of cliffs. The observation of a large number of small subaerial landslides being triggered by a single earthquake is also compatible with the hypothesis that failure occurs simultaneously in many locations within the area affected by ground shaking. Unlike submarine landslides, which are found on large uniformly-dipping slopes, a single large landslide scarp cannot form on land because of the heterogeneous morphology and short slope distances of tectonically-active subaerial regions. However, for a given earthquake magnitude, the total area affected by subaerial landslides is comparable to that calculated by slope stability analysis for submarine landslides. The area distribution of subaerial landslides from a single event may be determined by the size distribution of the morphology of the affected area, not by the initiation process. ?? 2009 Elsevier B.V.
Arthroscopic rotator cuff repair in the weight-bearing shoulder.
Kerr, Jacek; Borbas, Paul; Meyer, Dominik C; Gerber, Christian; Buitrago Téllez, Carlos; Wieser, Karl
2015-12-01
In wheelchair-dependent individuals, pain often develops because of rotator cuff tendon failure and/or osteoarthritis of the glenohumeral joint. The purposes of this study were to investigate (1) specific rotator cuff tear patterns, (2) structural healing, and (3) clinical outcomes after arthroscopic rotator cuff repair in a cohort of wheelchair-dependent patients. Forty-six shoulders with a mean follow-up of 46 months (range, 24-82 months; SD, 13 months) from a consecutive series of 61 shoulders in 56 patients (46 men and 10 women) undergoing arthroscopic rotator cuff repair were available for analysis. Clinical outcome analysis was performed using the Constant-Murley score, the Subjective Shoulder Value, and the American Shoulder and Elbow Surgeons score. The integrity of the repair was analyzed by ultrasound. Of the shoulders, 87% had supraspinatus involvement, 70% had subscapularis involvement, and 57% had an anterosuperior lesion involving both the supraspinatus and subscapularis. Despite an overall structural failure rate of 33%, the patients showed improvements in the Constant-Murley score from 50 points (range, 22-86 points; SD, 16 points) preoperatively to 80 points (range, 40-98 points; SD, 12 points) postoperatively and in the American Shoulder and Elbow Surgeons score from 56 points (range, 20-92 points; SD, 20 points) preoperatively to 92 points (range, 53-100 points; SD, 10 points) postoperatively, with a mean postoperative Subjective Shoulder Value of 84% (range, 25%-100%; SD, 17%). Failure of the rotator cuff in weight-bearing shoulders occurs primarily anterosuperiorly. Arthroscopic rotator cuff repair leads to a structural failure rate of 33% but satisfactory functional results with high patient satisfaction at midterm follow-up. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Orthopaedic jack for scoliosis surgery purposes: Concept and design
NASA Astrophysics Data System (ADS)
Supriadi, Sugeng; Radhana, Rakha M.; Hidayanto, Taufik Eko; Whulanza, Yudan; Ali, Notario, Nanda; Rahyussalim
2017-02-01
Scoliosis surgery is one of the most difficult orthopedic surgery that have been committed today as the failure rate of orthopedic surgery for adult patients is 15%. Aside from the long duration of surgery, this surgical failure is caused by failure in biomedical instrumentation. Furthermore, this kind of failure is causing inefficiency of the surgery. With current known orthopedic surgery method, three surgeons are needed in a single orthopedic surgery. In fact, a single surgery can take up to 8 hours to be done, which increases the risk of surgical failure. Based on this problem, authors hope that our orthopedic jacks could solve the problem.
26 CFR 1.6050H-0 - Table of contents.
Code of Federal Regulations, 2010 CFR
2010-04-01
..., 1989. (i) Failure to file return or to furnish statement. (ii) Failure to furnish TIN. (iii) Failure to...) Failure to furnish TIN. (iii) Failure to include correct information. (f) Requirement to request and to obtain TIN. (1) In general. (2) Manner of requesting TIN. (g) Effective date. (1) In general. (2) Points...
26 CFR 1.6050H-0 - Table of contents.
Code of Federal Regulations, 2014 CFR
2014-04-01
..., 1989. (i) Failure to file return or to furnish statement. (ii) Failure to furnish TIN. (iii) Failure to...) Failure to furnish TIN. (iii) Failure to include correct information. (f) Requirement to request and to obtain TIN. (1) In general. (2) Manner of requesting TIN. (g) Effective date. (1) In general. (2) Points...
26 CFR 1.6050H-0 - Table of contents.
Code of Federal Regulations, 2011 CFR
2011-04-01
..., 1989. (i) Failure to file return or to furnish statement. (ii) Failure to furnish TIN. (iii) Failure to...) Failure to furnish TIN. (iii) Failure to include correct information. (f) Requirement to request and to obtain TIN. (1) In general. (2) Manner of requesting TIN. (g) Effective date. (1) In general. (2) Points...
26 CFR 1.6050H-0 - Table of contents.
Code of Federal Regulations, 2013 CFR
2013-04-01
..., 1989. (i) Failure to file return or to furnish statement. (ii) Failure to furnish TIN. (iii) Failure to...) Failure to furnish TIN. (iii) Failure to include correct information. (f) Requirement to request and to obtain TIN. (1) In general. (2) Manner of requesting TIN. (g) Effective date. (1) In general. (2) Points...
26 CFR 1.6050H-0 - Table of contents.
Code of Federal Regulations, 2012 CFR
2012-04-01
..., 1989. (i) Failure to file return or to furnish statement. (ii) Failure to furnish TIN. (iii) Failure to...) Failure to furnish TIN. (iii) Failure to include correct information. (f) Requirement to request and to obtain TIN. (1) In general. (2) Manner of requesting TIN. (g) Effective date. (1) In general. (2) Points...
24 CFR 902.62 - Failure to submit data.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 24 Housing and Urban Development 4 2013-04-01 2013-04-01 false Failure to submit data. 902.62... DEVELOPMENT PUBLIC HOUSING ASSESSMENT SYSTEM PHAS Scoring § 902.62 Failure to submit data. (a) Failure to... receive a presumptive rating of failure for its unaudited information and shall receive zero points for...
24 CFR 902.62 - Failure to submit data.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 24 Housing and Urban Development 4 2012-04-01 2012-04-01 false Failure to submit data. 902.62... DEVELOPMENT PUBLIC HOUSING ASSESSMENT SYSTEM PHAS Scoring § 902.62 Failure to submit data. (a) Failure to... receive a presumptive rating of failure for its unaudited information and shall receive zero points for...
24 CFR 902.62 - Failure to submit data.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 24 Housing and Urban Development 4 2014-04-01 2014-04-01 false Failure to submit data. 902.62... DEVELOPMENT PUBLIC HOUSING ASSESSMENT SYSTEM PHAS Scoring § 902.62 Failure to submit data. (a) Failure to... receive a presumptive rating of failure for its unaudited information and shall receive zero points for...
Ianiro, G; Valerio, L; Masucci, L; Pecere, S; Bibbò, S; Quaranta, G; Posteraro, B; Currò, D; Sanguinetti, M; Gasbarrini, A; Cammarota, G
2017-05-01
Faecal microbiota transplantation (FMT) is an effective treatment for recurrent Clostridium difficile infection (CDI). Although a single faecal infusion is usually sufficient to eradicate CDI, a considerable number of patients need multiple infusions to be cured. The aim of this study was to identify predictors of failure after single faecal infusion in patients with recurrent CDI. We included patients with recurrent CDI prospectively treated with FMT by colonoscopy. By means of univariate and multivariate analysis, variables including female gender, age, number of CDI recurrences, severity of CDI, hospitalization, inadequate bowel preparation, unrelated donor, and use of frozen faeces, were assessed to predict failure after single faecal infusion. Sixty-four patients (39 women; mean age 74 years) were included. Of them, 44 (69%) were cured by a single faecal infusion, whereas 20 (31%) needed repeat infusions. Overall, FMT cured 62 of 64 (97%) patients. In the subgroup of patients with severe CDI, only eight of 26 (30%) were cured with a single infusion. At multivariate analysis, severe CDI (OR 24.66; 95% CI 4.44-242.08; p 0.001) and inadequate bowel preparation (OR 11.53; 95% CI 1.71-115.51; p 0.019) were found to be independent predictors of failure after single faecal infusion. Severe CDI and inadequate bowel preparation appear to be independent predictors of failure after single faecal infusion in patients treated with FMT by colonoscopy for recurrent CDI. Our results may help to optimize protocols and outcomes of FMT in patients with recurrent CDI. Copyright © 2016 European Society of Clinical Microbiology and Infectious Diseases. Published by Elsevier Ltd. All rights reserved.
Double-Row Capsulolabral Repair Increases Load to Failure and Decreases Excessive Motion.
McDonald, Lucas S; Thompson, Matthew; Altchek, David W; McGarry, Michelle H; Lee, Thay Q; Rocchi, Vanna J; Dines, Joshua S
2016-11-01
Using a cadaver shoulder instability model and load-testing device, we compared biomechanical characteristics of double-row and single-row capsulolabral repairs. We hypothesized a greater reduction in glenohumeral motion and translation and a higher load to failure in a mattress double-row capsulolabral repair than in a single-row repair. In 6 matched pairs of cadaveric shoulders, a capsulolabral injury was created. One shoulder was repaired with a single-row technique, and the other with a double-row mattress technique. Rotational range of motion, anterior-inferior translation, and humeral head kinematics were measured. Load-to-failure testing measured stiffness, yield load, deformation at yield load, energy absorbed at yield load, load to failure, deformation at ultimate load, and energy absorbed at ultimate load. Double-row repair significantly decreased external rotation and total range of motion compared with single-row repair. Both repairs decreased anterior-inferior translation compared with the capsulolabral-injured condition, however, no differences existed between repair types. Yield load in the single-row group was 171.3 ± 110.1 N, and in the double-row group it was 216.1 ± 83.1 N (P = .02). Ultimate load to failure in the single-row group was 224.5 ± 121.0 N, and in the double-row group it was 373.9 ± 172.0 N (P = .05). Energy absorbed at ultimate load in the single-row group was 1,745.4 ± 1,462.9 N-mm, and in the double-row group it was 4,649.8 ± 1,930.8 N-mm (P = .02). In cases of capsulolabral disruption, double-row repair techniques may result in decreased shoulder rotational range of motion and improved load-to-failure characteristics. In cases of capsulolabral disruption, repair techniques with double-row mattress repair may provide more secure fixation. Double-row capsulolabral repair decreases shoulder motion and increases load to failure, yield load, and energy absorbed at yield load more than single-row repair. Published by Elsevier Inc.
Embedded parallel processing based ground control systems for small satellite telemetry
NASA Technical Reports Server (NTRS)
Forman, Michael L.; Hazra, Tushar K.; Troendly, Gregory M.; Nickum, William G.
1994-01-01
The use of networked terminals which utilize embedded processing techniques results in totally integrated, flexible, high speed, reliable, and scalable systems suitable for telemetry and data processing applications such as mission operations centers (MOC). Synergies of these terminals, coupled with the capability of terminal to receive incoming data, allow the viewing of any defined display by any terminal from the start of data acquisition. There is no single point of failure (other than with network input) such as exists with configurations where all input data goes through a single front end processor and then to a serial string of workstations. Missions dedicated to NASA's ozone measurements program utilize the methodologies which are discussed, and result in a multimission configuration of low cost, scalable hardware and software which can be run by one flight operations team with low risk.
DynMo: Dynamic Simulation Model for Space Reactor Power Systems
NASA Astrophysics Data System (ADS)
El-Genk, Mohamed; Tournier, Jean-Michel
2005-02-01
A Dynamic simulation Model (DynMo) for space reactor power systems is developed using the SIMULINK® platform. DynMo is modular and could be applied to power systems with different types of reactors, energy conversion, and heat pipe radiators. This paper presents a general description of DynMo-TE for a space power system powered by a Sectored Compact Reactor (SCoRe) and that employs off-the-shelf SiGe thermoelectric converters. SCoRe is liquid metal cooled and designed for avoidance of a single point failure. The reactor core is divided into six equal sectors that are neutronically, but not thermal-hydraulically, coupled. To avoid a single point failure in the power system, each reactor sector has its own primary and secondary loops, and each loop is equipped with an electromagnetic (EM) pump. A Power Conversion assembly (PCA) and a Thermoelectric Conversion Assembly (TCA) of the primary and secondary EM pumps thermally couple each pair of a primary and a secondary loop. The secondary loop transports the heat rejected by the PCA and the pumps TCA to a rubidium heat pipes radiator panel. The primary loops transport the thermal power from the reactor sector to the PCAs for supplying a total of 145-152 kWe to the load at 441-452 VDC, depending on the selections of the primary and secondary liquid metal coolants. The primary and secondary coolant combinations investigated are lithium (Li)/Li, Li/sodium (Na), Na-Na, Li/NaK-78 and Na/NaK-78, for which the reactor exit temperature is kept below 1250 K. The results of a startup transient of the system from an initial temperature of 500 K are compared and discussed.
Early outcomes with a single-sided access endovascular stent.
Hofmann, Michael; Pecoraro, Felice; Planer, David; Pfammatter, Thomas; Puippe, Gilbert; Bettex, Dominique; Veith, Frank J; Lachat, Mario; Chaykovska, Lyubov
2018-03-27
The objective of this study was to report the 1-year follow-up study results of the new Horizon stent graft (Endospan, Herzliya, Israel) from two different prospective consecutive trials. The Horizon abdominal aortic aneurysm stent graft system is a 14F profile system requiring only a single access site. It consists of three modules, introduced separately: base limb (iliac to iliac limb); distal aortic limb; and proximal aortic limb with a bare suprarenal crown and active fixation. Data from the first in man (FIM) clinical study with 10 patients enrolled and the pivotal study with 30 patients were analyzed. Outcomes measured were freedom from major adverse events (MAEs) including all-cause mortality, myocardial infarction, renal failure, respiratory failure, paraplegia, stroke, bowel ischemia, and procedural blood loss ≥1000 mL. Performance end points included successful delivery and deployment of the device, freedom from aneurysm growth ≥5 mm, type I or type III endoleak, stent graft occlusion, conversion to open surgery, rupture, and stent graft migration. In the FIM study, one conversion to open surgery with >1000 mL of blood loss was registered perioperatively. In the pivotal study, no perioperative MAE was registered. Overall, at 1-year follow-up, two deaths and one aneurysm growth unrelated to endoleak were registered. The results of both the FIM and pivotal studies demonstrated that 39 of 40 procedures were successful for delivery and deployment of the Horizon stent graft. No MAE was registered during the follow-up. The primary safety and performance end points were met in both studies. Copyright © 2018 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.
Failure Rate of Single Dose Methotrexate in Managment of Ectopic Pregnancy
Sendy, Feras; AlShehri, Eman; AlAjmi, Amani; Bamanie, Elham; Appani, Surekha; Shams, Taghreed
2015-01-01
Background. One of the treatment modalities for ectopic pregnancy is methotrexate. The purpose of this study is to identify the failure rate of methotrexate in treating patients with ectopic pregnancy as well as the risk factors leading to treatment failure. Methods. A retrospective chart review of 225 patients who received methotrexate as a primary management option for ectopic pregnancy. Failure of single dose of methotrexate was defined as drop of BHCG level less than or equal to 14% in the seventh day after administration of methotrexate. Results. 225 patients had methotrexate. Most of the patients (151 (67%)) received methotrexate based on the following formula: f 50 mg X body surface area. Single dose of methotrexate was successful in 72% (162/225) of the patients. 28% (63/225) were labeled as failure of single dose of methotrexate because of suboptimal drop in BhCG. 63% (40/63) of failure received a second dose of methotrexate, and 37% (23/63) underwent surgical treatment. Among patient who received initial dose of methotrexate, 71% had moderate or severe pain, and 58% had ectopic mass size of more than 4 cm on ultrasound. Conclusion. Liberal use of medical treatment of ectopic pregnancy results in 71% success rate. PMID:25861275
NASA Technical Reports Server (NTRS)
Haakensen, Erik Edward
1998-01-01
The desire for low-cost reliable computing is increasing. Most current fault tolerant computing solutions are not very flexible, i.e., they cannot adapt to reliability requirements of newly emerging applications in business, commerce, and manufacturing. It is important that users have a flexible, reliable platform to support both critical and noncritical applications. Chameleon, under development at the Center for Reliable and High-Performance Computing at the University of Illinois, is a software framework. for supporting cost-effective adaptable networked fault tolerant service. This thesis details a simulation of fault injection, detection, and recovery in Chameleon. The simulation was written in C++ using the DEPEND simulation library. The results obtained from the simulation included the amount of overhead incurred by the fault detection and recovery mechanisms supported by Chameleon. In addition, information about fault scenarios from which Chameleon cannot recover was gained. The results of the simulation showed that both critical and noncritical applications can be executed in the Chameleon environment with a fairly small amount of overhead. No single point of failure from which Chameleon could not recover was found. Chameleon was also found to be capable of recovering from several multiple failure scenarios.
USE OF THE SDO POINTING CONTROLLERS FOR INSTRUMENT CALIBRATION MANEUVERS
NASA Technical Reports Server (NTRS)
Vess, Melissa F.; Starin, Scott R.; Morgenstern, Wendy M.
2005-01-01
During the science phase of the Solar Dynamics Observatory mission, the three science instruments require periodic instrument calibration maneuvers with a frequency of up to once per month. The command sequences for these maneuvers vary in length from a handful of steps to over 200 steps, and individual steps vary in size from 5 arcsec per step to 22.5 degrees per step. Early in the calibration maneuver development, it was determined that the original attitude sensor complement could not meet the knowledge requirements for the instrument calibration maneuvers in the event of a sensor failure. Because the mission must be single fault tolerant, an attitude determination trade study was undertaken to determine the impact of adding an additional attitude sensor versus developing alternative, potentially complex, methods of performing the maneuvers in the event of a sensor failure. To limit the impact to the science data capture budget, these instrument calibration maneuvers must be performed as quickly as possible while maintaining the tight pointing and knowledge required to obtain valid data during the calibration. To this end, the decision was made to adapt a linear pointing controller by adjusting gains and adding an attitude limiter so that it would be able to slew quickly and still achieve steady pointing once on target. During the analysis of this controller, questions arose about the stability of the controller during slewing maneuvers due to the combination of the integral gain, attitude limit, and actuator saturation. Analysis was performed and a method for disabling the integral action while slewing was incorporated to ensure stability. A high fidelity simulation is used to simulate the various instrument calibration maneuvers.
Thermal design, analysis and comparison on three concepts of space solar power satellite
NASA Astrophysics Data System (ADS)
Yang, Chen; Hou, Xinbin; Wang, Li
2017-08-01
Space solar power satellites (SSPS) have been widely studied as systems for collecting solar energy in space and transmitting it wirelessly to earth. A previously designed planar SSPS concept collects solar power in two huge arrays and then transmits it through one side of the power-conduction joint to the antenna. However, the system's one group of power-conduction joints may induce a single point of failure. As an SSPS concept, the module symmetrical concentrator (MSC) architecture has many advantages. This architecture can help avoid the need for a large, potentially failure-prone conductive rotating joint and limit wiring mass. However, the thermal control system has severely restricted the rapid development of MSC, especially in the sandwich module. Because of the synchronous existence of five suns concentration and solar external heat flux, the sandwich module will have a very high temperature, which will surpass the permissible temperature of the solar cells. Recently, an alternate multi-rotary joints (MR) SSPS concept was designed by the China Academy of Space Technology (CAST). This system has multiple joints to avoid the problem of a single point of failure. Meanwhile, this concept has another advantage for reducing the high power and heat removal in joints. It is well known to us that, because of the huge external flux in SSPS, the thermal management sub-system is an important component that cannot be neglected. Based on the three SSPS concepts, this study investigated the thermal design and analysis of a 1-km, gigawatt-level transmitting antenna in SSPS. This study compares the thermal management sub-systems of power-conduction joints in planar and MR SSPS. Moreover, the study considers three classic thermal control architectures of the MSC's sandwich module: tile, step, and separation. The study also presents an elaborate parameter design, analysis and discussion of step architecture. Finally, the results show the thermal characteristics of each SSPS concept, and the three concepts are compared. The design layouts, analysis results and parameter discussions of the thermal management sub-system proposed in this study can help inform future SSPS thermal designs.
Anthology of the Development of Radiation Transport Tools as Applied to Single Event Effects
NASA Astrophysics Data System (ADS)
Reed, R. A.; Weller, R. A.; Akkerman, A.; Barak, J.; Culpepper, W.; Duzellier, S.; Foster, C.; Gaillardin, M.; Hubert, G.; Jordan, T.; Jun, I.; Koontz, S.; Lei, F.; McNulty, P.; Mendenhall, M. H.; Murat, M.; Nieminen, P.; O'Neill, P.; Raine, M.; Reddell, B.; Saigné, F.; Santin, G.; Sihver, L.; Tang, H. H. K.; Truscott, P. R.; Wrobel, F.
2013-06-01
This anthology contains contributions from eleven different groups, each developing and/or applying Monte Carlo-based radiation transport tools to simulate a variety of effects that result from energy transferred to a semiconductor material by a single particle event. The topics span from basic mechanisms for single-particle induced failures to applied tasks like developing websites to predict on-orbit single event failure rates using Monte Carlo radiation transport tools.
Square-lashing technique in segmental spinal instrumentation: a biomechanical study.
Arlet, Vincent; Draxinger, Kevin; Beckman, Lorne; Steffen, Thomas
2006-07-01
Sublaminar wires have been used for many years for segmental spinal instrumentation in scoliosis surgery. More recently, stainless steel wires have been replaced by titanium cables. However, in rigid scoliotic curves, sublaminar wires or simple cables can either brake or pull out. The square-lashing technique was devised to avoid complications such as cable breakage or lamina cutout. The purpose of the study was therefore to test biomechanically the pull out and failure mode of simple sublaminar constructs versus the square-lashing technique. Individual vertebrae were subjected to pullout testing having one of two different constructs (single loop and square lashing) using either monofilament wire or multifilament cables. Four different methods of fixation were therefore tested: single wire construct, square-lashing wiring construct, single cable construct, and square-lashing cable construct. Ultimate failure load and failure mechanism were recorded. For the single wire the construct failed 12/16 times by wire breakage with an average ultimate failure load of 793 N. For the square-lashing wire the construct failed with pedicle fracture in 14/16, one bilateral lamina fracture, and one wire breakage. Ultimate failure load average was 1,239 N For the single cable the construct failed 12/16 times due to cable breakage (average force 1,162 N). 10/12 of these breakages were where the cable looped over the rod. For the square-lashing cable all of these constructs (16/16) failed by fracture of the pedicle with an average ultimate failure load of 1,388 N. The square-lashing construct had a higher pullout strength than the single loop and almost no cutting out from the lamina. The square-lashing technique with cables may therefore represent a new advance in segmental spinal instrumentation.
Single-event burnout of n-p-n bipolar-junction transistors in hybrid DC/DC converters
NASA Astrophysics Data System (ADS)
Warren, K.; Roth, D.; Kinnison, J.; Pappalardo, R.
2002-12-01
Single-event-induced failure of the Lambda Advanced Analog AMF2805S DC/DC Converter has been traced to burnout of an n-p-n transistor in the MOSFET drive stage. The failures were observed during testing while in inhibit mode only. Modifications to prevent burnout of the drive stage were successfully employed. A discussion of the failure mechanism and consequences for DC/DC converter testing are presented.
Masata, Jaromir; Svabik, Kamil; Zvara, Karel; Drahoradova, Petra; El Haddad, Rachid; Hubka, Petr; Martan, Alois
2012-10-01
The aim of this study was to compare the efficacy of the use of tension-free vaginal tape obturator (TVT-O) and single-incision TVT SECUR, hammock and U approach (TVT-S, H and U), in the treatment of urodynamic stress urinary incontinence (SUI). This single-center randomized three-arm trial compared the objective and subjective efficacy and early failure rate of the TVT-O and TVT-S H and U approach by objective criteria (cough test) and subjective criteria using the International Consultation on Incontinence Questionnaire--Short Form (ICIQ-UI SF). The objective efficacy rate was defined as the number of patients with a negative cough stress test. Subjective cure was defined by no stress leakage of urine after surgery based on the evaluation of ICIQ-UI SH (when patients ticked "Never"/"Urine does not leak" in answer to question 6: When does urine leak?). Objective and subjective efficacy were evaluated using Last Failure Carried Forward analysis, i.e., final analysis also included patients with early failure. To describe outcome at different time points, the Last Observation Carried Forward method was also implemented. One hundred ninety-seven women with proven SUI were randomized into three groups--TVT-O (n = 68), TVT-S H (n = 64), and TVT-S U (n = 65). Each patient allocated to a treatment group received the planned surgery. There were no differences in each group in preoperative characteristics. Median follow-up after surgery was 2 years (SD, 0.8; range, 0.1 to 3.8 years). Of the subjects, 92.6% in the TVT-O group, 68.8% in the TVT-S H group, and 69.2% in the TVT-S U group had negative stress test (p < 0.001). Of the subjects, 85.3 % in the TVT-O group, 68.8% in the TVT-S H group, and 61.5% in the TVT-S U group were subjectively continent (p = 0.02). Our study demonstrated a significantly lower subjective and objective cure rate in the single-incision TVT group compared to the TVT-O group.
Lala, Anuradha; McNulty, Steven E; Mentz, Robert J; Dunlay, Shannon M; Vader, Justin M; AbouEzzeddine, Omar F; DeVore, Adam D; Khazanie, Prateeti; Redfield, Margaret M; Goldsmith, Steven R; Bart, Bradley A; Anstrom, Kevin J; Felker, G Michael; Hernandez, Adrian F; Stevenson, Lynne W
2015-07-01
Congestion is the most frequent cause for hospitalization in acute decompensated heart failure. Although decongestion is a major goal of acute therapy, it is unclear how the clinical components of congestion (eg, peripheral edema, orthopnea) contribute to outcomes after discharge or how well decongestion is maintained. A post hoc analysis was performed of 496 patients enrolled in the Diuretic Optimization Strategy Evaluation in Acute Decompensated Heart Failure (DOSE-AHF) and Cardiorenal Rescue Study in Acute Decompensated Heart Failure (CARRESS-HF) trials during hospitalization with acute decompensated heart failure and clinical congestion. A simple orthodema congestion score was generated based on symptoms of orthopnea (≥2 pillows=2 points, <2 pillows=0 points) and peripheral edema (trace=0 points, moderate=1 point, severe=2 points) at baseline, discharge, and 60-day follow-up. Orthodema scores were classified as absent (score of 0), low-grade (score of 1-2), and high-grade (score of 3-4), and the association with death, rehospitalization, or unscheduled medical visits through 60 days was assessed. At baseline, 65% of patients had high-grade orthodema and 35% had low-grade orthodema. At discharge, 52% patients were free from orthodema at discharge (score=0) and these patients had lower 60-day rates of death, rehospitalization, or unscheduled visits (50%) compared with those with low-grade or high-grade orthodema (52% and 68%, respectively; P=0.038). Of the patients without orthodema at discharge, 27% relapsed to low-grade orthodema and 38% to high-grade orthodema at 60-day follow-up. Increased severity of congestion by a simple orthodema assessment is associated with increased morbidity and mortality. Despite intent to relieve congestion, current therapy often fails to relieve orthodema during hospitalization or to prevent recurrence after discharge. URL: http://www.clinicaltrials.gov. Unique identifiers: NCT00608491, NCT00577135. © 2015 American Heart Association, Inc.
The road less taken: modularization and waterways as a domestic disaster response mechanism.
Donahue, Donald A; Cunnion, Stephen O; Godwin, Evelyn A
2013-01-01
Preparedness scenarios project the need for significant healthcare surge capacity. Current planning draws heavily from the military model, leveraging deployable infrastructure to augment or replace extant capabilities. This approach would likely prove inadequate in a catastrophic disaster, as the military model relies on forewarning and an extended deployment cycle. Local equipping for surge capacity is prohibitively costly while movement of equipment can be subject to a single point of failure. Translational application of maritime logistical techniques and an ancient mode of transportation can provide a robust and customizable approach to disaster relief for greater than 90 percent of the American population.
Bone anchors or interference screws? A biomechanical evaluation for autograft ankle stabilization.
Jeys, Lee; Korrosis, Sotiris; Stewart, Todd; Harris, Nicholas J
2004-01-01
Autograft stabilization uses free semitendinosus tendon grafts to anatomically reconstruct the anterior talofibular ligament. Study aims were to evaluate the biomechanical properties of Mitek GII anchors compared with the Arthrex Bio-Tenodesis Screw for free tendon reconstruction of the anterior talofibular ligament. There are no differences in load to failure and percentage specimen elongation at failure between the 2 methods. Controlled laboratory study using porcine models. Sixty porcine tendon constructs were failure tested. Re-creating the pull of the anterior talofibular ligament, loads were applied at 70 degrees to the bones. Thirty-six tendons were fixed to porcine tali and tested using a single pull to failure; 10 were secured with anchors and No. 2 Ethibond, 10 with anchors and FiberWire, 10 with screws and Fiberwire, and 6 with partially gripped screws. Cyclic preloading was conducted on 6 tendons fixed by anchors and on 6 tendons fixed by screws before failure testing. Two groups of 6 components fixed to the fibula were also tested. The talus single-pull anchor group produced a mean load of 114 N and elongation of 37% at failure. The talus single-pull screw group produced a mean load of 227 N and elongation of 22% at failure (P <.05). Cyclic preloading at 65% failure load before failure testing produced increases in load and decreases in elongation at failure. Partially gripped screws produced a load of 133 N and elongation of 30% at failure. The fibula model produced significant increases in load to failure for both. The human anterior talofibular ligament has loads of 139 N at failure with instability occurring at 20% elongation. Interference screw fixation produced significantly greater failure strength and less elongation at failure than bone anchors. The improved biomechanics of interference screws suggests that these may be more suited to in vivo reconstruction of the anterior talofibular ligament than are bone anchors.
Failure at Frame-Stringer Intersections in PRSEUS Panels
NASA Technical Reports Server (NTRS)
Jegley, Dawn C.
2012-01-01
NASA, the Air Force Research Laboratory and The Boeing Company have worked to develop new low-cost, light-weight composite structures for aircraft. A Pultruded Rod Stitched Efficient Unitized Structure (PRSEUS) concept has been developed which offers advantages over traditional metallic structures. In this concept a stitched carbon-epoxy material system has been developed with the potential for reducing the weight and cost of transport aircraft structure by eliminating fasteners, thereby reducing part count and labor. By adding unidirectional carbon rods to the top of stiffeners, the panel becomes more structurally efficient. This combination produces a more damage tolerant design. This study focuses on the intersection between the rod-stiffener and the foam-filled frame in a PRSEUS specimen. Compression loading is considered, which induces stress concentrations at the intersection point that can lead to failures. An experiment with accompanying analysis for a single-frame specimen is described, followed by a parametric study of simple reinforcements to reduce strains in the intersection region.
On non-parametric maximum likelihood estimation of the bivariate survivor function.
Prentice, R L
The likelihood function for the bivariate survivor function F, under independent censorship, is maximized to obtain a non-parametric maximum likelihood estimator &Fcirc;. &Fcirc; may or may not be unique depending on the configuration of singly- and doubly-censored pairs. The likelihood function can be maximized by placing all mass on the grid formed by the uncensored failure times, or half lines beyond the failure time grid, or in the upper right quadrant beyond the grid. By accumulating the mass along lines (or regions) where the likelihood is flat, one obtains a partially maximized likelihood as a function of parameters that can be uniquely estimated. The score equations corresponding to these point mass parameters are derived, using a Lagrange multiplier technique to ensure unit total mass, and a modified Newton procedure is used to calculate the parameter estimates in some limited simulation studies. Some considerations for the further development of non-parametric bivariate survivor function estimators are briefly described.
Levine, Zachary H.; Pintar, Adam L.; Dobler, Jeremy T.; ...
2016-04-13
Laser absorption spectroscopy (LAS) has been used over the last several decades for the measurement of trace gasses in the atmosphere. For over a decade, LAS measurements from multiple sources and tens of retroreflectors have been combined with sparse-sample tomography methods to estimate the 2-D distribution of trace gas concentrations and underlying fluxes from point-like sources. In this work, we consider the ability of such a system to detect and estimate the position and rate of a single point leak which may arise as a failure mode for carbon dioxide storage. The leak is assumed to be at a constant ratemore » giving rise to a plume with a concentration and distribution that depend on the wind velocity. Lastly, we demonstrate the ability of our approach to detect a leak using numerical simulation and also present a preliminary measurement.« less
Spacecraft solid state power distribution switch
NASA Technical Reports Server (NTRS)
Praver, G. A.; Theisinger, P. C.
1986-01-01
As a spacecraft performs its mission, various loads are connected to the spacecraft power bus in response to commands from an on board computer, a function called power distribution. For the Mariner Mark II set of planetary missions, the power bus is 30 volts dc and when loads are connected or disconnected, both the bus and power return side must be switched. In addition, the power distribution function must be immune to single point failures and, when power is first applied, all switches must be in a known state. Traditionally, these requirements have been met by electromechanical latching relays. This paper describes a solid state switch which not only satisfies the requirements but incorporates several additional features including soft turn on, programmable current trip point with noise immunity, instantaneous current limiting, and direct telemetry of load currents and switch status. A breadboard of the design has been constructed and some initial test results are included.
Near-field transport of {sup 129}I from a point source in an in-room disposal vault
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kolar, M.; Leneveu, D.M.; Johnson, L.H.
1995-12-31
A very small number of disposal containers of heat generating nuclear waste may have initial manufacturing defects that would lead to pin-hole type failures at the time of or shortly after emplacement. For sufficiently long-lived containers, only the initial defects need to be considered in modeling of release rates from the disposal vault. Two approaches to modeling of near-field mass transport from a single point source within a disposal room have been compared: the finite-element code MOTIF (A Model Of Transport In Fractured/porous media) and a boundary integral method (BIM). These two approaches were found to give identical results formore » a simplified model of the disposal room without groundwater flow. MOTIF has then been used to study the effects of groundwater flow on the mass transport out of the emplacement room.« less
14 CFR 25.629 - Aeroelastic stability requirements.
Code of Federal Regulations, 2010 CFR
2010-01-01
... propeller or rotating device that contributes significant dynamic forces. Compliance with this section must...) Any single failure in any flutter damper system. (3) For airplanes not approved for operation in icing... dynamic forces, any single failure of the engine structure that would reduce the rigidity of the...
Rojas, Jhon; Blanco, Jose L; Sanchez-Palomino, Sonsoles; Marcos, Maria A; Guardo, Alberto C; Gonzalez-Cordon, Ana; Lonca, Montserrat; Tricas, Amparo; Rodriguez, Ana; Romero, Anabel; Miro, Jose M; Mallolas, Josep; Gatell, Jose M; Plana, Montserrat; Martinez, Esteban
2018-05-09
Antiretroviral drugs contained in single tablet Atripla® have pharmacokinetic properties that could allow for longer than once-daily (OD) dosing. We hypothesized that simplifying Atripla® OD to 3-day per week would be feasible, able to maintain viral suppression and less toxic. Virologically suppressed (≥2 years) HIV+ adults on Atripla® OD, CD4 >350/mm at inclusion, and no prior documented virological failure or evidence of resistance mutations to efavirenz, tenofovir, or emtricitabine were randomized to maintain their OD regimen or to reduce it to 3 days (Mondays, Wednesdays, and Fridays) a week (3W). Primary end-point was the proportion of patients free of treatment failure (non-completer = failure) at 24 weeks. CD4 and CD8 cells, ultrasensitive HIV-1 RNA, Pittsburg Sleep Quality Index (PSQI), bone mineral density, plasma efavirenz levels, and fasting blood and urine chemistries were measured at baseline and 24 weeks. The study is registered at ClinicalTrials.gov, NCT01778413. Sixty-one patients were randomized. All patients in both arms remained free of treatment failure (estimated difference 0%; 95% confidence interval -14.1 to 14.1). Ultrasensitive plasma HIV-1 RNA below detection threshold showed no difference between arms (70% in the 3W arm vs. 71% in the OD arm, P = 0.933) at 24 weeks. Total cholesterol and femur T-score significantly increased, while PSQI, plasma efavirenz, albumin/creatinine and beta-2-microglobulin in urine significantly decreased in the 3W arm relative to OD arm. The A-TRI-WEEK study represents a proof of concept for the feasibility of three-day per week Atripla® maintenance that should be further confirmed in a larger, well-powered clinical trial.
NASA Technical Reports Server (NTRS)
Eldridge, J. I.; Honecy, F. S.
1990-01-01
AES depth profiling and a fiber push-out test for interfacial shear-strength determination have been used to ascertain the mechanical/chemical properties of the fiber/matrix interface in SiC-reinforced reaction-bonded Si3N4, with attention to the weak point where interfacial failure occurs. In the cases of both composite fracture and fiber push-outs, the interfacial failure occurred either between the two C-rich coatings that are present on the double-coated SiC fibers, or between the inner C-rich coating and the SiC fiber. Interface failure occurs at points of very abrupt concentration changes.
Biomechanics of Polyhydroxyalkanoate Mesh-Augmented Single-Row Rotator Cuff Repairs.
Tashjian, Robert Z; Kolz, Christopher W; Suter, Thomas; Henninger, Heath B
Polyhydroxyalkanoate (PHA) mesh is a bioresorbable scaffold used to reinforce the suture-tendon interface in rotator cuff repairs (RCRs). We conducted a study of cyclic and ultimate failure properties of PHA mesh-augmented single-row RCRs and nonaugmented RCRs. Eight pairs of fresh-frozen cadaver humeri (6 male, 2 female) were tested. Mean (SD) age was 61 (9) years. The supraspinatus tendon was resected and reattached in a single-row configuration using 2 triple-loaded suture anchors and 6 simple stitches. The opposite humerus underwent RCR augmented with 2 strips of 13-mm × 23-mm PHA mesh. Humeri were mounted in an Instron load frame, cycled 1000 times to 1.0 MPa of effective stress, and loaded to failure. Construct gapping and ultimate failure loads/displacements were recorded. Paired t tests compared augmented and nonaugmented RCRs (P ≤ .05 was significant). There was no difference in gapping over 1000 cycles (P = .879). Mean (SD) failure load was higher for PHA mesh-augmented RCRs, 571 (173) N, than for nonaugmented (control) RCRs, 472 (120) N (P = .042), and failures were consistent within pairs because of tissue failure at the knots or anchor pullout. This technique for arthroscopic augmentation can be used to improve initial biomechanical repair strength in tears at risk for failure.
Tracking individual action potentials throughout mammalian axonal arbors.
Radivojevic, Milos; Franke, Felix; Altermatt, Michael; Müller, Jan; Hierlemann, Andreas; Bakkum, Douglas J
2017-10-09
Axons are neuronal processes specialized for conduction of action potentials (APs). The timing and temporal precision of APs when they reach each of the synapses are fundamentally important for information processing in the brain. Due to small diameters of axons, direct recording of single AP transmission is challenging. Consequently, most knowledge about axonal conductance derives from modeling studies or indirect measurements. We demonstrate a method to noninvasively and directly record individual APs propagating along millimeter-length axonal arbors in cortical cultures with hundreds of microelectrodes at microsecond temporal resolution. We find that cortical axons conduct single APs with high temporal precision (~100 µs arrival time jitter per mm length) and reliability: in more than 8,000,000 recorded APs, we did not observe any conduction or branch-point failures. Upon high-frequency stimulation at 100 Hz, successive became slower, and their arrival time precision decreased by 20% and 12% for the 100th AP, respectively.
Compound estimation procedures in reliability
NASA Technical Reports Server (NTRS)
Barnes, Ron
1990-01-01
At NASA, components and subsystems of components in the Space Shuttle and Space Station generally go through a number of redesign stages. While data on failures for various design stages are sometimes available, the classical procedures for evaluating reliability only utilize the failure data on the present design stage of the component or subsystem. Often, few or no failures have been recorded on the present design stage. Previously, Bayesian estimators for the reliability of a single component, conditioned on the failure data for the present design, were developed. These new estimators permit NASA to evaluate the reliability, even when few or no failures have been recorded. Point estimates for the latter evaluation were not possible with the classical procedures. Since different design stages of a component (or subsystem) generally have a good deal in common, the development of new statistical procedures for evaluating the reliability, which consider the entire failure record for all design stages, has great intuitive appeal. A typical subsystem consists of a number of different components and each component has evolved through a number of redesign stages. The present investigations considered compound estimation procedures and related models. Such models permit the statistical consideration of all design stages of each component and thus incorporate all the available failure data to obtain estimates for the reliability of the present version of the component (or subsystem). A number of models were considered to estimate the reliability of a component conditioned on its total failure history from two design stages. It was determined that reliability estimators for the present design stage, conditioned on the complete failure history for two design stages have lower risk than the corresponding estimators conditioned only on the most recent design failure data. Several models were explored and preliminary models involving bivariate Poisson distribution and the Consael Process (a bivariate Poisson process) were developed. Possible short comings of the models are noted. An example is given to illustrate the procedures. These investigations are ongoing with the aim of developing estimators that extend to components (and subsystems) with three or more design stages.
Predicting the Lifetime of Dynamic Networks Experiencing Persistent Random Attacks.
Podobnik, Boris; Lipic, Tomislav; Horvatic, Davor; Majdandzic, Antonio; Bishop, Steven R; Eugene Stanley, H
2015-09-21
Estimating the critical points at which complex systems abruptly flip from one state to another is one of the remaining challenges in network science. Due to lack of knowledge about the underlying stochastic processes controlling critical transitions, it is widely considered difficult to determine the location of critical points for real-world networks, and it is even more difficult to predict the time at which these potentially catastrophic failures occur. We analyse a class of decaying dynamic networks experiencing persistent failures in which the magnitude of the overall failure is quantified by the probability that a potentially permanent internal failure will occur. When the fraction of active neighbours is reduced to a critical threshold, cascading failures can trigger a total network failure. For this class of network we find that the time to network failure, which is equivalent to network lifetime, is inversely dependent upon the magnitude of the failure and logarithmically dependent on the threshold. We analyse how permanent failures affect network robustness using network lifetime as a measure. These findings provide new methodological insight into system dynamics and, in particular, of the dynamic processes of networks. We illustrate the network model by selected examples from biology, and social science.
New methods for the condition monitoring of level crossings
NASA Astrophysics Data System (ADS)
García Márquez, Fausto Pedro; Pedregal, Diego J.; Roberts, Clive
2015-04-01
Level crossings represent a high risk for railway systems. This paper demonstrates the potential to improve maintenance management through the use of intelligent condition monitoring coupled with reliability centred maintenance (RCM). RCM combines advanced electronics, control, computing and communication technologies to address the multiple objectives of cost effectiveness, improved quality, reliability and services. RCM collects digital and analogue signals utilising distributed transducers connected to either point-to-point or digital bus communication links. Assets in many industries use data logging capable of providing post-failure diagnostic support, but to date little use has been made of combined qualitative and quantitative fault detection techniques. The research takes the hydraulic railway level crossing barrier (LCB) system as a case study and develops a generic strategy for failure analysis, data acquisition and incipient fault detection. For each barrier the hydraulic characteristics, the motor's current and voltage, hydraulic pressure and the barrier's position are acquired. In order to acquire the data at a central point efficiently, without errors, a distributed single-cable Fieldbus is utilised. This allows the connection of all sensors through the project's proprietary communication nodes to a high-speed bus. The system developed in this paper for the condition monitoring described above detects faults by means of comparing what can be considered a 'normal' or 'expected' shape of a signal with respect to the actual shape observed as new data become available. ARIMA (autoregressive integrated moving average) models were employed for detecting faults. The statistical tests known as Jarque-Bera and Ljung-Box have been considered for testing the model.
Page, Michael M; Taranto, Mario; Ramsay, Duncan; van Schie, Greg; Glendenning, Paul; Gillett, Melissa J; Vasikaran, Samuel D
2018-01-01
Objective Primary aldosteronism is a curable cause of hypertension which can be treated surgically or medically depending on the findings of adrenal vein sampling studies. Adrenal vein sampling studies are technically demanding with a high failure rate in many centres. The use of intraprocedural cortisol measurement could improve the success rates of adrenal vein sampling but may be impracticable due to cost and effects on procedural duration. Design Retrospective review of the results of adrenal vein sampling procedures since commencement of point-of-care cortisol measurement using a novel single-use semi-quantitative measuring device for cortisol, the adrenal vein sampling Accuracy Kit. Success rate and complications of adrenal vein sampling procedures before and after use of the adrenal vein sampling Accuracy Kit. Routine use of the adrenal vein sampling Accuracy Kit device for intraprocedural measurement of cortisol commenced in 2016. Results Technical success rate of adrenal vein sampling increased from 63% of 99 procedures to 90% of 48 procedures ( P = 0.0007) after implementation of the adrenal vein sampling Accuracy Kit. Failure of right adrenal vein cannulation was the main reason for an unsuccessful study. Radiation dose decreased from 34.2 Gy.cm 2 (interquartile range, 15.8-85.9) to 15.7 Gy.cm 2 (6.9-47.3) ( P = 0.009). No complications were noted, and implementation costs were minimal. Conclusions Point-of-care cortisol measurement during adrenal vein sampling improved cannulation success rates and reduced radiation exposure. The use of the adrenal vein sampling Accuracy Kit is now standard practice at our centre.
Flight performance of Skylab attitude and pointing control system
NASA Technical Reports Server (NTRS)
Chubb, W. B.; Kennel, H. F.; Rupp, C. C.; Seltzer, S. M.
1975-01-01
The Skylab attitude and pointing control system (APCS) requirements are briefly reviewed and the way in which they became altered during the prelaunch phase of development is noted. The actual flight mission (including mission alterations during flight) is described. The serious hardware failures that occurred, beginning during ascent through the atmosphere, also are described. The APCS's ability to overcome these failures and meet mission changes are presented. The large around-the-clock support effort on the ground is discussed. Salient design points and software flexibility that should afford pertinent experience for future spacecraft attitude and pointing control system designs are included.
1988-06-01
densities of Mississippi River point bar sands . 73. It is particularly conclusive to compare the available critical void ratio data for point bar sands on... River encounters the difficulty that the density of large parts of Zone A sands is between the upper and lower critical densities . All laboratory... sands of the Lower Mississippi River point bar deposits generally contain some strata of subcritical density , and the initial tendenc% of such sands
Stress Analysis of B-52B and B-52H Air-Launching Systems Failure-Critical Structural Components
NASA Technical Reports Server (NTRS)
Ko, William L.
2005-01-01
The operational life analysis of any airborne failure-critical structural component requires the stress-load equation, which relates the applied load to the maximum tangential tensile stress at the critical stress point. The failure-critical structural components identified are the B-52B Pegasus pylon adapter shackles, B-52B Pegasus pylon hooks, B-52H airplane pylon hooks, B-52H airplane front fittings, B-52H airplane rear pylon fitting, and the B-52H airplane pylon lower sway brace. Finite-element stress analysis was performed on the said structural components, and the critical stress point was located and the stress-load equation was established for each failure-critical structural component. The ultimate load, yield load, and proof load needed for operational life analysis were established for each failure-critical structural component.
Patel, Salma I; Chakkera, Harini A; Wennberg, Paul W; Liedl, David A; Alrabadi, Fadi; Cha, Stephen S; Hooley, Darren D; Amer, Hatem; Wadei, Hani M; Shamoun, Fadi E
2017-06-01
Patients with end-stage renal disease undergoing kidney transplant often have diffuse atherosclerosis and high cardiovascular morbidity and mortality rates. We analyzed the correlation of peripheral arterial disease (PAD), here quantified by an abnormal ankle-brachial index (ABI) measured within the 5 years prior to kidney transplant, with graft failure and mortality rates (primary end points) after adjusting for known cardiovascular risk factors (age, sex, smoking history, hypertension, diabetes, stroke, known coronary artery disease or heart failure, years of dialysis). Of 1055 patients in our transplant population, 819 had arterial studies within the 5 years prior to transplant. Secondary end points included myocardial infarction; cerebrovascular accident; and limb ischemia, gangrene, or amputation. Low ABI was an independent and significant predictor of organ failure (OR, 2.77 (95% CI, 1.68-4.58), p<0.001), secondary end points (HR, 1.39 (95% CI, 0.97-1.99), p<0.076), and death (HR, 1.84 (95% CI, 1.26-2.68), p=0.002). PAD was common in this population: of 819 kidney transplant recipients, 46% had PAD. Low ABI was associated with a threefold greater risk of graft failure, a twofold greater risk of death after transplant, and a threefold greater risk of secondary end points. Screening for PAD is important in this patient population because of the potential impact on long-term outcomes.
Laughner, Jacob I; Sulkin, Matthew S; Wu, Ziqi; Deng, Cheri X; Efimov, Igor R
2012-04-01
High intensity focused ultrasound (HIFU) has been introduced for treatment of cardiac arrhythmias because it offers the ability to create rapid tissue modification in confined volumes without directly contacting the myocardium. In spite of the benefits of HIFU, a number of limitations have been reported, which hindered its clinical adoption. In this study, we used a multimodal approach to evaluate thermal and nonthermal effects of HIFU in cardiac ablation. We designed a computer controlled system capable of simultaneous fluorescence mapping and HIFU ablation. Using this system, linear lesions were created in isolated rabbit atria (n=6), and point lesions were created in the ventricles of whole-heart (n=6) preparations by applying HIFU at clinical doses (4-16 W). Additionally, we evaluate the gap size in ablation lines necessary for conduction in atrial preparations (n=4). The voltage sensitive dye di-4-ANEPPS was used to assess functional damage produced by HIFU. Optical coherence tomography and general histology were used to evaluate lesion extent. Conduction block was achieved in 1 (17%) of 6 atrial preparations with a single ablation line. Following 10 minutes of rest, 0 (0%) of 6 atrial preparations demonstrated sustained conduction block from a single ablation line. Tissue displacement of 1 to 3 mm was observed during HIFU application due to acoustic radiation force along the lesion line. Additionally, excessive acoustic pressure and high temperature from HIFU generated cavitation, causing macroscopic tissue damage. A minimum gap size of 1.5 mm was found to conduct electric activity. This study identified 3 potential mechanisms responsible for the failure of HIFU ablation in cardiac tissues. Both acoustic radiation force and acoustic cavitation, in conjunction with inconsistent thermal deposition, can increase the risk of lesion discontinuity and result in gap sizes that promote ablation failure.
Destructive Single-Event Effects in Diodes
NASA Technical Reports Server (NTRS)
Casey, Megan C.; Lauenstein, Jean-Marie; Campola, Michael J.; Wilcox, Edward P.; Phan, Anthony M.; Label, Kenneth A.
2017-01-01
In this work, we discuss the observed single-event effects in a variety of types of diodes. In addition, we conduct failure analysis on several Schottky diodes that were heavy-ion irradiated. High- and low-magnitude optical microscope images, infrared camera images, and scanning electron microscope images are used to identify and describe the failure locations.
Triaxial testing of Lopez Fault gouge at 150 MPa mean effective stress
Scott, D.R.; Lockner, D.A.; Byerlee, J.D.; Sammis, C.G.
1994-01-01
Triaxial compression experiments were performed on samples of natural granular fault gouge from the Lopez Fault in Southern California. This material consists primarily of quartz and has a self-similar grain size distribution thought to result from natural cataclasis. The experiments were performed at a constant mean effective stress of 150 MPa, to expose the volumetric strains associated with shear failure. The failure strength is parameterized by the coefficient of internal friction ??, based on the Mohr-Coulomb failure criterion. Samples of remoulded Lopez gouge have internal friction ??=0.6??0.02. In experiments where the ends of the sample are constrained to remain axially aligned, suppressing strain localisation, the sample compacts before failure and dilates persistently after failure. In experiments where one end of the sample is free to move laterally, the strain localises to a single oblique fault at around the point of failure; some dilation occurs but does not persist. A comparison of these experiments suggests that dilation is confined to the region of shear localisation in a sample. Overconsolidated samples have slightly larger failure strengths than normally consolidated samples, and smaller axial strains are required to cause failure. A large amount of dilation occurs after failure in heavily overconsolidated samples, suggesting that dilation is occurring throughout the sample. Undisturbed samples of Lopez gouge, cored from the outcrop, have internal friction in the range ??=0.4-0.6; the upper end of this range corresponds to the value established for remoulded Lopez gouge. Some kind of natural heterogeneity within the undisturbed samples is probably responsible for their low, variable strength. In samples of simulated gouge, with a more uniform grain size, active cataclasis during axial loading leads to large amounts of compaction. Larger axial strains are required to cause failure in simulated gouge, but the failure strength is similar to that of natural Lopez gouge. Use of the Mohr-Coulomb failure criterion to interpret the results from this study, and other recent studies on intact rock and granular gouge, leads to values of ?? that depend on the loading configuration and the intact or granular state of the sample. Conceptual models are advanced to account for these descrepancies. The consequences for strain-weakening of natural faults are also discussed. ?? 1994 Birkha??user Verlag.
Precision Pointing in Space Using Arrays of Shape Memory Based Linear Actuators
NASA Astrophysics Data System (ADS)
Sonawane, Nikhil
Space systems such as communication satellites, earth observation satellites and telescope require accurate pointing to observe fixed targets over prolonged time. These systems typically use reaction wheels to slew the spacecraft and gimballing systems containing motors to achieve precise pointing. Motor based actuators have limited life as they contain moving parts that require lubrication in space. Alternate methods have utilized piezoelectric actuators. This paper presents Shape memory alloys (SMA) actuators for control of a deployable antenna placed on a satellite. The SMAs are operated as a series of distributed linear actuators. These distributed linear actuators are not prone to single point failures and although each individual actuator is imprecise due to hysteresis and temperature variation, the system as a whole achieves reliable results. The SMAs can be programmed to perform a series of periodic motion and operate as a mechanical guidance system that is not prone to damage from radiation or space weather. Efforts are focused on developing a system that can achieve 1 degree pointing accuracy at first, with an ultimate goal of achieving a few arc seconds accuracy. Bench top model of the actuator system has been developed and working towards testing the system under vacuum. A demonstration flight of the technology is planned aboard a CubeSat.
Failure Mechanisms of Hollow Fiber Supported Ionic Liquid Membranes
Zeh, Matthew; Wickramanayake, Shan; Hopkinson, David
2016-01-01
Hollow fiber supported ionic liquid membranes (SILMs) were tested using the bubble point method to investigate potential failure modes, including the maximum transmembrane pressure before loss of the ionic liquid from the support. Porous hollow fiber supports were fabricated with different pore morphologies using Matrimid® and Torlon® as the polymeric material and 1-hexyl-3-methylimidalzolium bis(trifluoromethylsulfonyl)imide ([C6mim][Tf2N]) as the ionic liquid (IL) component. Hollow fiber SILMs were tested for their maximum pressure before failure, with pressure applied either from the bore side or shell side. It was found that the membranes exhibited one or more of three different modes of failure when pressurized: liquid loss (occurring at the bubble point), rupture, and collapse. PMID:27023620
Gilks, Charles F; Walker, A Sarah; Munderi, Paula; Kityo, Cissy; Reid, Andrew; Katabira, Elly; Goodall, Ruth L; Grosskurth, Heiner; Mugyenyi, Peter; Hakim, James; Gibb, Diana M
2013-01-01
In low-income countries, viral load (VL) monitoring of antiretroviral therapy (ART) is rarely available in the public sector for HIV-infected adults or children. Using clinical failure alone to identify first-line ART failure and trigger regimen switch may result in unnecessary use of costly second-line therapy. Our objective was to identify CD4 threshold values to confirm clinically-determined ART failure when VL is unavailable. 3316 HIV-infected Ugandan/Zimbabwean adults were randomised to first-line ART with Clinically-Driven (CDM, CD4s measured but blinded) or routine Laboratory and Clinical Monitoring (LCM, 12-weekly CD4s) in the DART trial. CD4 at switch and ART failure criteria (new/recurrent WHO 4, single/multiple WHO 3 event; LCM: CD4<100 cells/mm(3)) were reviewed in 361 LCM, 314 CDM participants who switched over median 5 years follow-up. Retrospective VLs were available in 368 (55%) participants. Overall, 265/361 (73%) LCM participants failed with CD4<100 cells/mm(3); only 7 (2%) switched with CD4≥250 cells/mm(3), four switches triggered by WHO events. Without CD4 monitoring, 207/314 (66%) CDM participants failed with WHO 4 events, and 77(25%)/30(10%) with single/multiple WHO 3 events. Failure/switching with single WHO 3 events was more likely with CD4≥250 cells/mm(3) (28/77; 36%) (p = 0.0002). CD4 monitoring reduced switching with viral suppression: 23/187 (12%) LCM versus 49/181 (27%) CDM had VL<400 copies/ml at failure/switch (p<0.0001). Amongst CDM participants with CD4<250 cells/mm(3) only 11/133 (8%) had VL<400 copies/ml, compared with 38/48 (79%) with CD4≥250 cells/mm(3) (p<0.0001). Multiple, but not single, WHO 3 events predicted first-line ART failure. A CD4 threshold 'tiebreaker' of ≥250 cells/mm(3) for clinically-monitored patients failing first-line could identify ∼80% with VL<400 copies/ml, who are unlikely to benefit from second-line. Targeting CD4s to single WHO stage 3 'clinical failures' would particularly avoid premature, costly switch to second-line ART.
NASA Astrophysics Data System (ADS)
Baqersad, Javad; Niezrecki, Christopher; Avitabile, Peter
2015-10-01
Health monitoring of rotating structures (e.g. wind turbines and helicopter blades) has historically been a challenge due to sensing and data transmission problems. Unfortunately mechanical failure in many structures initiates at components on or inside the structure where there is no sensor located to predict the failure. In this paper, a wind turbine was mounted with a semi-built-in configuration and was excited using a mechanical shaker. A series of optical targets was distributed along the blades and the fixture and the displacement of those targets during excitation was measured using a pair of high speed cameras. Measured displacements with three dimensional point tracking were transformed to all finite element degrees of freedom using a modal expansion algorithm. The expanded displacements were applied to the finite element model to predict the full-field dynamic strain on the surface of the structure as well as within the interior points. To validate the methodology of dynamic strain prediction, the predicted strain was compared to measured strain by using six mounted strain-gages. To verify if a simpler model of the turbine can be used for the expansion, the expansion process was performed both by using the modes of the entire turbine and modes of a single cantilever blade. The results indicate that the expansion approach can accurately predict the strain throughout the turbine blades from displacements measured by using stereophotogrammetry.
NASA Technical Reports Server (NTRS)
Schmeckpeper, K. R.
1987-01-01
The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA approach features a top-down analysis of the hardware to determine failure modes, criticality, and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. This report documents the independent analysis results corresponding to the Orbiter Electrical Power Distribution and Control (EPD and C) hardware. The EPD and C hardware performs the functions of distributing, sensing, and controlling 28 volt DC power and of inverting, distributing, sensing, and controlling 117 volt 400 Hz AC power to all Orbiter subsystems from the three fuel cells in the Electrical Power Generation (EPG) subsystem. Each level of hardware was evaluated and analyzed for possible failure modes and effects. Criticality was assigned based upon the severity of the effect for each failure mode. Of the 1671 failure modes analyzed, 9 single failures were determined to result in loss of crew or vehicle. Three single failures unique to intact abort were determined to result in possible loss of the crew or vehicle. A possible loss of mission could result if any of 136 single failures occurred. Six of the criticality 1/1 failures are in two rotary and two pushbutton switches that control External Tank and Solid Rocket Booster separation. The other 6 criticality 1/1 failures are fuses, one each per Aft Power Control Assembly (APCA) 4, 5, and 6 and one each per Forward Power Control Assembly (FPCA) 1, 2, and 3, that supply power to certain Main Propulsion System (MPS) valves and Forward Reaction Control System (RCS) circuits.
Subcritical crack growth in SiNx thin-film barriers studied by electro-mechanical two-point bending
NASA Astrophysics Data System (ADS)
Guan, Qingling; Laven, Jozua; Bouten, Piet C. P.; de With, Gijsbertus
2013-06-01
Mechanical failure resulting from subcritical crack growth in the SiNx inorganic barrier layer applied on a flexible multilayer structure was studied by an electro-mechanical two-point bending method. A 10 nm conducting tin-doped indium oxide layer was sputtered as an electrical probe to monitor the subcritical crack growth in the 150 nm dielectric SiNx layer carried by a polyethylene naphthalate substrate. In the electro-mechanical two-point bending test, dynamic and static loads were applied to investigate the crack propagation in the barrier layer. As consequence of using two loading modes, the characteristic failure strain and failure time could be determined. The failure probability distribution of strain and lifetime under each loading condition was described by Weibull statistics. In this study, results from the tests in dynamic and static loading modes were linked by a power law description to determine the critical failure over a range of conditions. The fatigue parameter n from the power law reduces greatly from 70 to 31 upon correcting for internal strain. The testing method and analysis tool as described in the paper can be used to understand the limit of thin-film barriers in terms of their mechanical properties.
Analysis of rainfall-induced slope instability using a field of local factor of safety
Lu, Ning; Şener-Kaya, Başak; Wayllace, Alexandra; Godt, Jonathan W.
2012-01-01
Slope-stability analyses are mostly conducted by identifying or assuming a potential failure surface and assessing the factor of safety (FS) of that surface. This approach of assigning a single FS to a potentially unstable slope provides little insight on where the failure initiates or the ultimate geometry and location of a landslide rupture surface. We describe a method to quantify a scalar field of FS based on the concept of the Coulomb stress and the shift in the state of stress toward failure that results from rainfall infiltration. The FS at each point within a hillslope is called the local factor of safety (LFS) and is defined as the ratio of the Coulomb stress at the current state of stress to the Coulomb stress of the potential failure state under the Mohr-Coulomb criterion. Comparative assessment with limit-equilibrium and hybrid finite element limit-equilibrium methods show that the proposed LFS is consistent with these approaches and yields additional insight into the geometry and location of the potential failure surface and how instability may initiate and evolve with changes in pore water conditions. Quantitative assessments applying the new LFS field method to slopes under infiltration conditions demonstrate that the LFS has the potential to overcome several major limitations in the classical FS methodologies such as the shape of the failure surface and the inherent underestimation of slope instability. Comparison with infinite-slope methods, including a recent extension to variably saturated conditions, shows further enhancement in assessing shallow landslide occurrence using the LFS methodology. Although we use only a linear elastic solution for the state of stress with no post-failure analysis that require more sophisticated elastoplastic or other theories, the LFS provides a new means to quantify the potential instability zones in hillslopes under variably saturated conditions using stress-field based methods.
Foster, Tim; Willetts, Juliet; Lane, Mike; Thomson, Patrick; Katuva, Jacob; Hope, Rob
2018-06-01
An improved understanding of failure risks for water supplies in rural sub-Saharan Africa will be critical to achieving the global goal of safe water for all by 2030. In the absence of longitudinal biophysical and operational data, investigations into water point failure risk factors have to date been limited to cross-sectional research designs. This retrospective cohort study applies survival analysis to identify factors that predict failure risks for handpumps installed on boreholes along the south coast of Kenya from the 1980s. The analysis is based on a unique dataset linking attributes of >300 water points at the time of installation with their operational lifespan over the following decades. Cox proportional hazards and accelerated failure time models suggest water point failure risks are higher and lifespans are shorter when water supplied is more saline, static water level is deeper, and groundwater is pumped from an unconsolidated sand aquifer. The risk of failure also appears to grow as distance to spare part suppliers increases. To bolster the sustainability of rural water services and ensure no community is left behind, post-construction support mechanisms will need to mitigate heterogeneous environmental and geographical challenges. Further studies are needed to better understand the causal pathways that underlie these risk factors in order to inform policies and practices that ensure water services are sustained even where unfavourable conditions prevail. Copyright © 2018 Elsevier B.V. All rights reserved.
Bekelman, David B; Allen, Larry A; McBryde, Connor F; Hattler, Brack; Fairclough, Diane L; Havranek, Edward P; Turvey, Carolyn; Meek, Paula M
2018-04-01
Many patients with chronic heart failure experience reduced health status despite receiving conventional therapy. To determine whether a symptom and psychosocial collaborative care intervention improves heart failure-specific health status, depression, and symptom burden in patients with heart failure. A single-blind, 2-arm, multisite randomized clinical trial was conducted at Veterans Affairs, academic, and safety-net health systems in Colorado among outpatients with symptomatic heart failure and reduced health status recruited between August 2012 and April 2015. Data from all participants were included regardless of level of participation, using an intent-to-treat approach. Patients were randomized 1:1 to receive the Collaborative Care to Alleviate Symptoms and Adjust to Illness (CASA) intervention or usual care. The CASA intervention included collaborative symptom care provided by a nurse and psychosocial care provided by a social worker, both of whom worked with the patients' primary care clinicians and were supervised by a study primary care clinician, cardiologist, and palliative care physician. The primary outcome was patient-reported heart failure-specific health status, measured by difference in change scores on the Kansas City Cardiomyopathy Questionnaire (range, 0-100) at 6 months. Secondary outcomes included depression (measured by the 9-item Patient Health Questionnaire), anxiety (measured by the 7-item Generalized Anxiety Disorder Questionnaire), overall symptom distress (measured by the General Symptom Distress Scale), specific symptoms (pain, fatigue, and shortness of breath), number of hospitalizations, and mortality. Of 314 patients randomized (157 to intervention arm and 157 to control arm), there were 67 women and 247 men, mean (SD) age was 65.5 (11.4) years, and 178 (56.7%) had reduced ejection fraction. At 6 months, the mean Kansas City Cardiomyopathy Questionnaire score improved 5.5 points in the intervention arm and 2.9 points in the control arm (difference, 2.6; 95% CI, -1.3 to 6.6; P = .19). Among secondary outcomes, depressive symptoms and fatigue improved at 6 months with CASA (effect size of -0.29 [95% CI, -0.53 to -0.04] for depressive symptoms and -0.30 [95% CI, -0.55 to -0.06] for fatigue; P = .02 for both). There were no significant changes in overall symptom distress, pain, shortness of breath, or number of hospitalizations. Mortality at 12 months was similar in both arms (10 patients died receiving CASA, and 13 patients died receiving usual care; P = .52). This multisite randomized clinical trial of the CASA intervention did not demonstrate improved heart failure-specific health status. Secondary outcomes of depression and fatigue, both difficult symptoms to treat in heart failure, improved. clinicaltrials.gov Identifier: NCT01739686.
NASA Astrophysics Data System (ADS)
Baró, Jordi; Dahmen, Karin A.; Davidsen, Jörn; Planes, Antoni; Castillo, Pedro O.; Nataf, Guillaume F.; Salje, Ekhard K. H.; Vives, Eduard
2018-06-01
The total energy of acoustic emission (AE) events in externally stressed materials diverges when approaching macroscopic failure. Numerical and conceptual models explain this accelerated seismic release (ASR) as the approach to a critical point that coincides with ultimate failure. Here, we report ASR during soft uniaxial compression of three silica-based (SiO2 ) nanoporous materials. Instead of a singular critical point, the distribution of AE energies is stationary, and variations in the activity rate are sufficient to explain the presence of multiple periods of ASR leading to distinct brittle failure events. We propose that critical failure is suppressed in the AE statistics by mechanisms of transient hardening. Some of the critical exponents estimated from the experiments are compatible with mean field models, while others are still open to interpretation in terms of the solution of frictional and fracture avalanche models.
Gaussian process surrogates for failure detection: A Bayesian experimental design approach
NASA Astrophysics Data System (ADS)
Wang, Hongqiao; Lin, Guang; Li, Jinglai
2016-05-01
An important task of uncertainty quantification is to identify the probability of undesired events, in particular, system failures, caused by various sources of uncertainties. In this work we consider the construction of Gaussian process surrogates for failure detection and failure probability estimation. In particular, we consider the situation that the underlying computer models are extremely expensive, and in this setting, determining the sampling points in the state space is of essential importance. We formulate the problem as an optimal experimental design for Bayesian inferences of the limit state (i.e., the failure boundary) and propose an efficient numerical scheme to solve the resulting optimization problem. In particular, the proposed limit-state inference method is capable of determining multiple sampling points at a time, and thus it is well suited for problems where multiple computer simulations can be performed in parallel. The accuracy and performance of the proposed method is demonstrated by both academic and practical examples.
Simon, Indoctrination and Ethical Relativism.
ERIC Educational Resources Information Center
Wagner, Paul A.
1981-01-01
Points to three deficiencies in values clarification as a program of moral education; i.e., failure to distinguish the intellectual traits essential in moral valuing; failure to contribute to students' moral development; and failure to consider the purpose and mechanics of moral argument. Concludes that values clarification promotes ethical…
Determination of Failure Point of Asphalt-Mixture Fatigue-Test Results Using the Flow Number Method
NASA Astrophysics Data System (ADS)
Wulan, C. E. P.; Setyawan, A.; Pramesti, F. P.
2018-03-01
The failure point of the results of fatigue tests of asphalt mixtures performed in controlled stress mode is difficult to determine. However, several methods from empirical studies are available to solve this problem. The objectives of this study are to determine the fatigue failure point of the results of indirect tensile fatigue tests using the Flow Number Method and to determine the best Flow Number model for the asphalt mixtures tested. In order to achieve these goals, firstly the best asphalt mixture of three was selected based on their Marshall properties. Next, the Indirect Tensile Fatigue Test was performed on the chosen asphalt mixture. The stress-controlled fatigue tests were conducted at a temperature of 20°C and frequency of 10 Hz, with the application of three loads: 500, 600, and 700 kPa. The last step was the application of the Flow Number methods, namely the Three-Stages Model, FNest Model, Francken Model, and Stepwise Method, to the results of the fatigue tests to determine the failure point of the specimen. The chosen asphalt mixture is EVA (Ethyl Vinyl Acetate) polymer -modified asphalt mixture with 6.5% OBC (Optimum Bitumen Content). Furthermore, the result of this study shows that the failure points of the EVA-modified asphalt mixture under loads of 500, 600, and 700 kPa are 6621, 4841, and 611 for the Three-Stages Model; 4271, 3266, and 537 for the FNest Model; 3401, 2431, and 421 for the Francken Model, and 6901, 6841, and 1291 for the Stepwise Method, respectively. These different results show that the bigger the loading, the smaller the number of cycles to failure. However, the best FN results are shown by the Three-Stages Model and the Stepwise Method, which exhibit extreme increases after the constant development of accumulated strain.
Common Cause Failures and Ultra Reliability
NASA Technical Reports Server (NTRS)
Jones, Harry W.
2012-01-01
A common cause failure occurs when several failures have the same origin. Common cause failures are either common event failures, where the cause is a single external event, or common mode failures, where two systems fail in the same way for the same reason. Common mode failures can occur at different times because of a design defect or a repeated external event. Common event failures reduce the reliability of on-line redundant systems but not of systems using off-line spare parts. Common mode failures reduce the dependability of systems using off-line spare parts and on-line redundancy.
Neutron-induced single event burnout in high voltage electronics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Normand, E.; Wert, J.L.; Oberg, D.L.
Energetic neutrons with an atmospheric neutron spectrum, which were demonstrated to induce single event burnout in power MOSFETs, have been shown to induce burnout in high voltage (>3,000V) electronics when operated at voltages as low as 50% of rated voltage. The laboratory failure rates correlate well with field failure rates measured in Europe.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-23
... Boeing Model 787-8 airplane will incorporate a fuel tank nitrogen generation system (NGS) that actively... ignition source in the fuel tank system could not result from any single failure, from any single failure... of fuel systems. We do not intend to apply the alternative standards used under these special...
Composite Overwrapped Pressure Vessel (COPV) Stress Rupture Testing
NASA Technical Reports Server (NTRS)
Greene, Nathanael J.; Saulsberry, Regor L.; Leifeste, Mark R.; Yoder, Tommy B.; Keddy, Chris P.; Forth, Scott C.; Russell, Rick W.
2010-01-01
This paper reports stress rupture testing of Kevlar(TradeMark) composite overwrapped pressure vessels (COPVs) at NASA White Sands Test Facility. This 6-year test program was part of the larger effort to predict and extend the lifetime of flight vessels. Tests were performed to characterize control parameters for stress rupture testing, and vessel life was predicted by statistical modeling. One highly instrumented 102-cm (40-in.) diameter Kevlar(TradeMark) COPV was tested to failure (burst) as a single-point model verification. Significant data were generated that will enhance development of improved NDE methods and predictive modeling techniques, and thus better address stress rupture and other composite durability concerns that affect pressure vessel safety, reliability and mission assurance.
Possible generational effects of habitat degradation on alligator reproduction
Fujisaki, Ikuko; Rice, K.G.; Woodward, A.R.; Percival, H.F.
2007-01-01
Population decline of the American alligator (Alligator mississippiensis) was observed in Lake Apopka in central Florida, USA, in the early 1980s. This decline was thought to result from adult mortality and nest failure caused by anthropogenic increases in sediment loads, nutrients, and contaminants. Reproductive impairment also was reported. Extensive restoration of marshes associated with Lake Apopka has been conducted, as well as some limited restoration measures on the lake. Monitoring by the Florida Fish and Wildlife Conservation Commission (FFWCC) has indicated that the adult alligator population began increasing in the early 1990s. We expected that the previously reported high proportion of complete nest failure (??0) during the 1980s may have decreased. We collected clutches from alligator nests in Lake Apopka from 1983 to 2003 and from 5 reference areas from 1988 to 1991, and we artificially incubated them. We used a Bayesian framework with Gibbs sampler of Markov chain Monte Carlo simulation to analyze ??0. Estimated ??0was consistently higher in Lake Apopka compared with reference areas, and the difference in ??0 ranged from 0.19 to 0.56. We conducted change point analysis to identify and test the significance of the change point in ??0in Lake Apopka between 1983 and 2003, indicating the point of reproductive recovery. The estimated Bayes factor strongly supported the single change point hypothesis against the no change point hypothesis. The major downward shift in ??0 probably occurred in the mid-1990s, approximately a generation after the major population decline in the 1980s. Furthermore, estimated ??0 values after the change point (0.21) were comparable with those of reference areas (0.07-0.31). These results combined with the monitoring by FFWCC seem to suggest that anthropogenic habitat degradation caused reproductive impairment of adult females and decreases in ??0 occurred with the sexual maturity of a new generation of breeding females. Long-term monitoring is essential to understand population changes due to habitat restoration. Such information can be used as an input in planning and evaluating restoration activities.
McNair, Patrick; Jones, Erica; Truong, Quynh; Singh, Harsimran
Single coronary artery is a rare clinical finding. Diagnosis is typically made incidentally after the patient presents with symptoms and undergoes coronary angiography, coronary computed tomography angiography (CTA), or post-mortem during autopsy. Several high-risk features of anomalous coronary arteries have been described in the literature. Our paper describes a case of dilated alcoholic cardiomyopathy presenting as heart failure with diagnostic workup incidentally revealing single coronary artery. Copyright © 2017 Elsevier Inc. All rights reserved.
Wininger, Fred A; Kapatkin, Amy S; Radin, Alex; Shofer, Frances S; Smith, Gail K
2007-12-01
To compare failure mode and bending moment of a canine pancarpal arthrodesis construct using either a 2.7 mm/3.5 mm hybrid dynamic compression plate (HDCP) or a 3.5 mm dynamic compression plate (DCP). Paired in vitro biomechanical testing of canine pancarpal arthrodesis constructs stabilized with either a 2.7/3.5 HDCP or 3.5 DCP. Paired cadaveric canine antebrachii (n=5). Pancarpal arthrodesis constructs were loaded to failure (point of maximum load) in 4-point bending using a materials-testing machine. Using this point of failure, bending moments were calculated from system variables for each construct and the 2 plating systems compared using a paired t-test. To examine the relationship between metacarpal diameter and screw diameter failure loads, linear regression was used and Pearson' correlation coefficient was calculated. Significance was set at P<.05. HDCP failed at higher loads than DCP for 9 of 10 constructs. The absolute difference in failure rates between the 2 plates was 0.552+/-0.182 N m, P=.0144 (95% confidence interval: -0.58 to 1.68). This is an 8.1% mean difference in bending strength. There was a significant linear correlation r=0.74 (P-slope=.014) and 0.8 (P-slope=.006) between metacarpal diameter and failure loads for the HDCP and 3.5 DCP, respectively. There was a small but significant difference between bending moment at failure between 2.7/3.5 HDCP and 3.5 DCP constructs; however, the difference may not be clinically evident in all patients. The 2.7/3.5 HDCP has physical and mechanical properties making it a more desirable plate for pancarpal arthrodesis.
Sano, Toshikazu; Ousaka, Daiki; Goto, Takuya; Ishigami, Shuta; Hirai, Kenta; Kasahara, Shingo; Ohtsuki, Shinichi; Sano, Shunji; Oh, Hidemasa
2018-03-30
Intracoronary administration of cardiosphere-derived cells (CDCs) in patients with single ventricles resulted in a short-term improvement in cardiac function. To test the hypothesis that CDC infusion is associated with improved cardiac function and reduced mortality in patients with heart failure. We evaluated the effectiveness of CDCs using an integrated cohort study in 101 patients with single ventricles, including 41 patients who received CDC infusion and 60 controls treated with staged palliation alone. Heart failure with preserved ejection fraction (EF) or reduced EF was stratified by the cardiac function after surgical reconstruction. The main outcome measure was to evaluate the magnitude of improvement in cardiac function and all-cause mortality at 2 years. Animal studies were conducted to clarify the underlying mechanisms of heart failure with preserved EF and heart failure with reduced EF phenotypes. At 2 years, CDC infusion increased ventricular function (stage 2: +8.4±10.0% versus +1.6±6.4%, P =0.03; stage 3: +7.9±7.5% versus -1.1±5.5%, P <0.001) compared with controls. In all available follow-up data, survival did not differ between the 2 groups (log-rank P =0.225), whereas overall patients treated by CDCs had lower incidences of late failure ( P =0.022), adverse events ( P =0.013), and catheter intervention ( P =0.005) compared with controls. CDC infusion was associated with a lower risk of adverse events (hazard ratio, 0.411; 95% CI, 0.179-0.942; P =0.036). Notably, CDC infusion reduced mortality ( P =0.038) and late complications ( P <0.05) in patients with heart failure with reduced EF but not with heart failure with preserved EF. CDC-treated rats significantly reversed myocardial fibrosis with differential collagen deposition and inflammatory responses between the heart failure phenotypes. CDC administration in patients with single ventricles showed favorable effects on ventricular function and was associated with reduced late complications except for all-cause mortality after staged procedures. Patients with heart failure with reduced EF but not heart failure with preserved EF treated by CDCs resulted in significant improvement in clinical outcome. URL: http://www.clinicaltrials.gov. Unique identifiers: NCT01273857 and NCT01829750. © 2018 American Heart Association, Inc.
Outcomes of Basic Versus Advanced Life Support for Out-of-Hospital Medical Emergencies.
Sanghavi, Prachi; Jena, Anupam B; Newhouse, Joseph P; Zaslavsky, Alan M
2015-11-03
Most Medicare patients seeking emergency medical transport are treated by ambulance providers trained in advanced life support (ALS). Evidence supporting the superiority of ALS over basic life support (BLS) is limited, but some studies suggest ALS may harm patients. To compare outcomes after ALS and BLS in out-of-hospital medical emergencies. Observational study with adjustment for propensity score weights and instrumental variable analyses based on county-level variations in ALS use. Traditional Medicare. 20% random sample of Medicare beneficiaries from nonrural counties between 2006 and 2011 with major trauma, stroke, acute myocardial infarction (AMI), or respiratory failure. Neurologic functioning and survival to 30 days, 90 days, 1 year, and 2 years. Except in cases of AMI, patients showed superior unadjusted outcomes with BLS despite being older and having more comorbidities. In propensity score analyses, survival to 90 days among patients with trauma, stroke, and respiratory failure was higher with BLS than ALS (6.1 percentage points [95% CI, 5.4 to 6.8 percentage points] for trauma; 7.0 percentage points [CI, 6.2 to 7.7 percentage points] for stroke; and 3.7 percentage points [CI, 2.5 to 4.8 percentage points] for respiratory failure). Patients with AMI did not exhibit differences in survival at 30 days but had better survival at 90 days with ALS (1.0 percentage point [CI, 0.1 to 1.9 percentage points]). Neurologic functioning favored BLS for all diagnoses. Results from instrumental variable analyses were broadly consistent with propensity score analyses for trauma and stroke, showed no survival differences between BLS and ALS for respiratory failure, and showed better survival at all time points with BLS than ALS for patients with AMI. Only Medicare beneficiaries from nonrural counties were studied. Advanced life support is associated with substantially higher mortality for several acute medical emergencies than BLS. National Science Foundation, Agency for Healthcare Research and Quality, and National Institutes of Health.
Opfermann, Krisha J; Wahlquist, Amy; Watkins, John; Kohler, Matthew; Jenrette, Joseph
2012-03-01
To evaluate whether Point A asymmetry in low dose-rate (LDR) brachytherapy is associated with local control (LC), disease-free survival (DFS) and/or overall survival (OS). A retrospective analysis of disease control and survival outcomes was conducted for patients who underwent LDR brachytherapy for advanced cervical cancer. Institutional protocol entailed concurrent chemotherapy and whole pelvis radiotherapy (WPRT) over 5 weeks, followed by placement of Fletcher-Suit tandem and colpostat applicators at weeks 6 and 8. Objective Point A doses, 80-85 Gy, were accomplished by placement of Cesium-137 (Cs-137) sources. Cox proportional hazards regression models were used to assess associations between disease control and survival endpoints with variables of interest. The records of 50 patients with FIGO stage IB1-IVA cervical cancer undergoing LDR brachytherapy at our institution were identified. Thirty of these patients had asymmetry > 2.5%, and 11 patients had asymmetry > 5%. At a median survivor follow-up of 20.25 months, 15 patients had experienced disease failure (including 5 cervical/vaginal apex only failures and 2 failures encompassing the local site). Right/left dose asymmetry at Point A was associated with statistically significantly inferior LC (p = 0.035) and inferior DFS (p = 0.011) for patients with mean Point A dose of > 80 Gy. Insufficient evidence existed to conclude an association with OS. LDR brachytherapy may be associated with clinically significant dose asymmetry. The present study demonstrates that patients with Point A asymmetry have a higher risk of failure for DFS and LC.
Wahlquist, Amy; Watkins, John; Kohler, Matthew; Jenrette, Joseph
2012-01-01
Purpose To evaluate whether Point A asymmetry in low dose-rate (LDR) brachytherapy is associated with local control (LC), disease-free survival (DFS) and/or overall survival (OS). Material and methods A retrospective analysis of disease control and survival outcomes was conducted for patients who underwent LDR brachytherapy for advanced cervical cancer. Institutional protocol entailed concurrent chemotherapy and whole pelvis radiotherapy (WPRT) over 5 weeks, followed by placement of Fletcher-Suit tandem and colpostat applicators at weeks 6 and 8. Objective Point A doses, 80-85 Gy, were accomplished by placement of Cesium-137 (Cs-137) sources. Cox proportional hazards regression models were used to assess associations between disease control and survival endpoints with variables of interest. Results The records of 50 patients with FIGO stage IB1-IVA cervical cancer undergoing LDR brachytherapy at our institution were identified. Thirty of these patients had asymmetry > 2.5%, and 11 patients had asymmetry > 5%. At a median survivor follow-up of 20.25 months, 15 patients had experienced disease failure (including 5 cervical/vaginal apex only failures and 2 failures encompassing the local site). Right/left dose asymmetry at Point A was associated with statistically significantly inferior LC (p = 0.035) and inferior DFS (p = 0.011) for patients with mean Point A dose of > 80 Gy. Insufficient evidence existed to conclude an association with OS. Conclusions LDR brachytherapy may be associated with clinically significant dose asymmetry. The present study demonstrates that patients with Point A asymmetry have a higher risk of failure for DFS and LC. PMID:23346133
A bivariate model for analyzing recurrent multi-type automobile failures
NASA Astrophysics Data System (ADS)
Sunethra, A. A.; Sooriyarachchi, M. R.
2017-09-01
The failure mechanism in an automobile can be defined as a system of multi-type recurrent failures where failures can occur due to various multi-type failure modes and these failures are repetitive such that more than one failure can occur from each failure mode. In analysing such automobile failures, both the time and type of the failure serve as response variables. However, these two response variables are highly correlated with each other since the timing of failures has an association with the mode of the failure. When there are more than one correlated response variables, the fitting of a multivariate model is more preferable than separate univariate models. Therefore, a bivariate model of time and type of failure becomes appealing for such automobile failure data. When there are multiple failure observations pertaining to a single automobile, such data cannot be treated as independent data because failure instances of a single automobile are correlated with each other while failures among different automobiles can be treated as independent. Therefore, this study proposes a bivariate model consisting time and type of failure as responses adjusted for correlated data. The proposed model was formulated following the approaches of shared parameter models and random effects models for joining the responses and for representing the correlated data respectively. The proposed model is applied to a sample of automobile failures with three types of failure modes and up to five failure recurrences. The parametric distributions that were suitable for the two responses of time to failure and type of failure were Weibull distribution and multinomial distribution respectively. The proposed bivariate model was programmed in SAS Procedure Proc NLMIXED by user programming appropriate likelihood functions. The performance of the bivariate model was compared with separate univariate models fitted for the two responses and it was identified that better performance is secured by the bivariate model. The proposed model can be used to determine the time and type of failure that would occur in the automobiles considered here.
MOLAR: Modular Linux and Adaptive Runtime Support for HEC OS/R Research
DOE Office of Scientific and Technical Information (OSTI.GOV)
Frank Mueller
2009-02-05
MOLAR is a multi-institution research effort that concentrates on adaptive, reliable,and efficient operating and runtime system solutions for ultra-scale high-end scientific computing on the next generation of supercomputers. This research addresses the challenges outlined by the FAST-OS - forum to address scalable technology for runtime and operating systems --- and HECRTF --- high-end computing revitalization task force --- activities by providing a modular Linux and adaptable runtime support for high-end computing operating and runtime systems. The MOLAR research has the following goals to address these issues. (1) Create a modular and configurable Linux system that allows customized changes based onmore » the requirements of the applications, runtime systems, and cluster management software. (2) Build runtime systems that leverage the OS modularity and configurability to improve efficiency, reliability, scalability, ease-of-use, and provide support to legacy and promising programming models. (3) Advance computer reliability, availability and serviceability (RAS) management systems to work cooperatively with the OS/R to identify and preemptively resolve system issues. (4) Explore the use of advanced monitoring and adaptation to improve application performance and predictability of system interruptions. The overall goal of the research conducted at NCSU is to develop scalable algorithms for high-availability without single points of failure and without single points of control.« less
NASA Astrophysics Data System (ADS)
Kim, S. Y.; Yoo, J. H.; Kim, H. K.; Shin, K. Y.; Yoon, S. J.
2018-06-01
In this paper, we discussed the structural behavior of bolted lap-joint connections in pultruded FRP structural members. Especially, bolted connections in pultruded FRP members are investigated for their failure modes and strength. Specimens with single and multiple bolt-holes are tested in tension under bolt-loading conditions. All of the specimens are instrumented with strain gages and the load-strain responses are monitored. The failed specimens are examined for the cracks and failure patterns. The purpose of this paper is to predict the failure strength by using the ratio of the results obtained by the experiment and the finite element analysis. In the study, several tests are conducted to determine the mechanical properties of pultruded FRP materials before the main experiment. The results are used in the finite element analysis for single and multiple bolted lap-joint specimens. The results obtained by the experiment are compared with the results obtained by the finite element analysis.
McCormick, Norman J.
1976-01-01
For use in the identification of failed fuel assemblies in a nuclear reactor, the ratios of the tag gas isotopic concentrations are located on curved surfaces to enable the ratios corresponding to failure of a single fuel assembly to be distinguished from those formed from any combination of two or more failed assemblies.
NASA Technical Reports Server (NTRS)
Bonnice, W. F.; Wagner, E.; Motyka, P.; Hall, S. R.
1985-01-01
The performance of the detection filter in detecting and isolating aircraft control surface and actuator failures is evaluated. The basic detection filter theory assumption of no direct input-output coupling is violated in this application due to the use of acceleration measurements for detecting and isolating failures. With this coupling, residuals produced by control surface failures may only be constrained to a known plane rather than to a single direction. A detection filter design with such planar failure signatures is presented, with the design issues briefly addressed. In addition, a modification to constrain the residual to a single known direction even with direct input-output coupling is also presented. Both the detection filter and the modification are tested using a nonlinear aircraft simulation. While no thresholds were selected, both filters demonstrated an ability to detect control surface and actuator failures. Failure isolation may be a problem if there are several control surfaces which produce similar effects on the aircraft. In addition, the detection filter was sensitive to wind turbulence and modeling errors.
Wu, Jia-Rong; DeWalt, Darren A; Baker, David W; Schillinger, Dean; Ruo, Bernice; Bibbins-Domingo, Kristen; Macabasco-O'Connell, Aurelia; Holmes, George M; Broucksou, Kimberly A; Erman, Brian; Hawk, Victoria; Cene, Crystal W; Jones, Christine DeLong; Pignone, Michael
2014-09-01
To determine whether a single-item self-report medication adherence question predicts hospitalisation and death in patients with heart failure. Poor medication adherence is associated with increased morbidity and mortality. Having a simple means of identifying suboptimal medication adherence could help identify at-risk patients for interventions. We performed a prospective cohort study in 592 participants with heart failure within a four-site randomised trial. Self-report medication adherence was assessed at baseline using a single-item question: 'Over the past seven days, how many times did you miss a dose of any of your heart medication?' Participants who reported no missing doses were defined as fully adherent, and those missing more than one dose were considered less than fully adherent. The primary outcome was combined all-cause hospitalisation or death over one year and the secondary endpoint was heart failure hospitalisation. Outcomes were assessed with blinded chart reviews, and heart failure outcomes were determined by a blinded adjudication committee. We used negative binomial regression to examine the relationship between medication adherence and outcomes. Fifty-two percent of participants were 52% male, mean age was 61 years, and 31% were of New York Heart Association class III/IV at enrolment; 72% of participants reported full adherence to their heart medicine at baseline. Participants with full medication adherence had a lower rate of all-cause hospitalisation and death (0·71 events/year) compared with those with any nonadherence (0·86 events/year): adjusted-for-site incidence rate ratio was 0·83, fully adjusted incidence rate ratio 0·68. Incidence rate ratios were similar for heart failure hospitalisations. A single medication adherence question at baseline predicts hospitalisation and death over one year in heart failure patients. Medication adherence is associated with all-cause and heart failure-related hospitalisation and death in heart failure. It is important for clinicians to assess patients' medication adherence on a regular basis at their clinical follow-ups. © 2013 John Wiley & Sons Ltd.
NASA Technical Reports Server (NTRS)
Schneeweiss, W.
1977-01-01
It is shown how the availability and MTBF (Mean Time Between Failures) of a redundant system with subsystems maintenanced at the points of so-called stationary renewal processes can be determined from the distributions of the intervals between maintenance actions and of the failure-free operating intervals of the subsystems. The results make it possible, for example, to determine the frequency and duration of hidden failure states in computers which are incidentally corrected during the repair of observed failures.
Failure-free survival after second-line systemic treatment of chronic graft-versus-host disease
Storer, Barry E.; Lee, Stephanie J.; Carpenter, Paul A.; Sandmaier, Brenda M.; Flowers, Mary E. D.; Martin, Paul J.
2013-01-01
This study attempted to characterize causes of treatment failure, identify associated prognostic factors, and develop shorter-term end points for trials testing investigational products or regimens for second-line systemic treatment of chronic graft-versus-host disease (GVHD). The study cohort (312 patients) received second-line systemic treatment of chronic GVHD. The primary end point was failure-free survival (FFS) defined by the absence of third-line treatment, nonrelapse mortality, and recurrent malignancy during second-line treatment. Treatment change was the major cause of treatment failure. FFS was 56% at 6 months after second-line treatment. Lower steroid doses at 6 months correlated with subsequent withdrawal of immunosuppressive treatment. Multivariate analysis showed that high-risk disease at transplantation, lower gastrointestinal involvement at second-line treatment, and severe NIH global score at second-line treatment were associated with increased risks of treatment failure. These three factors were used to define risk groups, and success rates at 6 months were calculated for each risk group either without or with various steroid dose limits at 6 months as an additional criterion of success. These success rates could be used as the basis for a clinically relevant and efficient shorter-term end point in clinical studies that evaluate agents for second-line systemic treatment of chronic GVHD. PMID:23321253
What Have We Learned from Communication Design Failure?
ERIC Educational Resources Information Center
Poggenpohl, Sharon; Winkler, Dietmar R.
2010-01-01
In closing, the guest editors of this "Visible Language" special series reflect on the failures identified in the various papers and interpret what this suggests for design education and research in the context of changing practice. The failures cited in this series point out the fractures in our understanding and practices from user-centered,…
Caballero Morales, Santiago Omar
2013-01-01
The application of Preventive Maintenance (PM) and Statistical Process Control (SPC) are important practices to achieve high product quality, small frequency of failures, and cost reduction in a production process. However there are some points that have not been explored in depth about its joint application. First, most SPC is performed with the X-bar control chart which does not fully consider the variability of the production process. Second, many studies of design of control charts consider just the economic aspect while statistical restrictions must be considered to achieve charts with low probabilities of false detection of failures. Third, the effect of PM on processes with different failure probability distributions has not been studied. Hence, this paper covers these points, presenting the Economic Statistical Design (ESD) of joint X-bar-S control charts with a cost model that integrates PM with general failure distribution. Experiments showed statistically significant reductions in costs when PM is performed on processes with high failure rates and reductions in the sampling frequency of units for testing under SPC. PMID:23527082
Dobson, Ian; Carreras, Benjamin A; Lynch, Vickie E; Newman, David E
2007-06-01
We give an overview of a complex systems approach to large blackouts of electric power transmission systems caused by cascading failure. Instead of looking at the details of particular blackouts, we study the statistics and dynamics of series of blackouts with approximate global models. Blackout data from several countries suggest that the frequency of large blackouts is governed by a power law. The power law makes the risk of large blackouts consequential and is consistent with the power system being a complex system designed and operated near a critical point. Power system overall loading or stress relative to operating limits is a key factor affecting the risk of cascading failure. Power system blackout models and abstract models of cascading failure show critical points with power law behavior as load is increased. To explain why the power system is operated near these critical points and inspired by concepts from self-organized criticality, we suggest that power system operating margins evolve slowly to near a critical point and confirm this idea using a power system model. The slow evolution of the power system is driven by a steady increase in electric loading, economic pressures to maximize the use of the grid, and the engineering responses to blackouts that upgrade the system. Mitigation of blackout risk should account for dynamical effects in complex self-organized critical systems. For example, some methods of suppressing small blackouts could ultimately increase the risk of large blackouts.
Quantifying Pilot Contribution to Flight Safety during Hydraulic Systems Failure
NASA Technical Reports Server (NTRS)
Kramer, Lynda J.; Etherington, Timothy J.; Bailey, Randall E.; Kennedy, Kellie D.
2017-01-01
Accident statistics cite the flight crew as a causal factor in over 60% of large transport aircraft fatal accidents. Yet, a well-trained and well-qualified pilot is acknowledged as the critical center point of aircraft systems safety and an integral safety component of the entire commercial aviation system. The latter statement, while generally accepted, cannot be verified because little or no quantitative data exists on how and how many accidents/incidents are averted by crew actions. A joint NASA/FAA high-fidelity motion-base human-in-the-loop test was conducted using a Level D certified Boeing 737-800 simulator to evaluate the pilot's contribution to safety-of-flight during routine air carrier flight operations and in response to aircraft system failures. To quantify the human's contribution, crew complement (two-crew, reduced crew, single pilot) was used as the independent variable in a between-subjects design. This paper details the crew's actions, including decision-making, and responses while dealing with a hydraulic systems leak - one of 6 total non-normal events that were simulated in this experiment.
Drug user treatment failure blindness?
Einstein, Stan
2012-01-01
An ethnographic case study of a "failed" single goal (abstinence) based individual and group therapy treatment of a New York City, Harlem-based, single, young-adult of color, IDU, mother, which ended in "death by overdose," after a period of abstinence, is presented almost 50 years later, in which complex, multidimensional structural barriers, "normed," consensualized, ideologically-driven preconceptions and an array of contextual, situational and relevant stakeholder factors, which may have resulted in intervention "failure blindness," are reviewed. The need to introduce failure analysis, blindness and management, as well as success analysis, blindness and management, as integral parts of treatment planning, implementation and assessment is raised.
Monolithic Flexure Pre-Stressed Ultrasonic Horns
NASA Technical Reports Server (NTRS)
Sherrit, Stewart; Bao, Xiaoqi; Badescu, Mircea; Bar-Cohen, Yoseph; Allen, Phillip Grant
2011-01-01
High-power ultrasonic actuators are generally assembled with a horn, backing, stress bolt, piezoelectric rings, and electrodes. The manufacturing process is complex, expensive, difficult, and time-consuming. The internal stress bolt needs to be insulated and presents a potential internal discharge point, which can decrease actuator life. Also, the introduction of a center hole for the bolt causes many failures, reducing the throughput of the manufactured actuators. A new design has been developed for producing ultrasonic horn actuators. This design consists of using flexures rather than stress bolts, allowing one to apply pre-load to the piezoelectric material. It also allows one to manufacture them from a single material/plate, rapid prototype them, or make an array in a plate or 3D structure. The actuator is easily assembled, and application of pre-stress greater than 25 MPa was demonstrated. The horn consists of external flexures that eliminate the need for the conventional stress bolt internal to the piezoelectric, and reduces the related complexity. The stress bolts are required in existing horns to provide prestress on piezoelectric stacks when driven at high power levels. In addition, the manufacturing process benefits from the amenability to produce horn structures with internal cavities. The removal of the pre-stress bolt removes a potential internal electric discharge point in the actuator. In addition, it significantly reduces the chances of mechanical failure in the piezoelectric stacks that result from the hole surface in conventional piezoelectric actuators. The novel features of this disclosure are: 1. A design that can be manufactured from a single piece of metal using EDM, precision machining, or rapid prototyping. 2. Increased electromechanical coupling of the horn actuator. 3. Higher energy density. 4. A monolithic structure of a horn that consists of an external flexure or flexures that can be used to pre-stress a solid piezoelectric structure rather than a bolt, which requires a through hole in the piezoelectric material. 5. A flexure system with low stiffness that accommodates mechanical creep with minor reduction in pre-stress.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wijesooriya, K; Seitter, K; Desai, V
Purpose: To present our single institution experience on catching errors with trajectory log file analysis. The reported causes of failures, probability of occurrences (O), severity of effects (S), and the probability of the failures to be undetected (D) could be added to guidelines of FMEA analysis. Methods: From March 2013 to March 2014, 19569 patient treatment fields/arcs were analyzed. This work includes checking all 131 treatment delivery parameters for all patients, all treatment sites and all treatment delivery fractions. TrueBeam trajectory log files for all treatment field types as well as all imaging types were accessed, read in every 20ms,more » and every control point (total of 37 million parameters) compared to the physician approved plan in the planning system. Results: Couch angle outlier occurrence: N= 327, range = −1.7 −1.2 deg; gantry angle outlier occurrence: N =59, range = 0.09 – 5.61 deg, collimator angle outlier occurrence: N = 13, range = −0.2 – 0.2 deg. VMAT cases have slightly larger variations in mechanical parameters. MLC: 3D single control point fields have a maximum deviation of 0.04 mm, 39 step and shoot IMRT cases have MLC −0.3 – 0.5 mm deviations, all (1286) VMAT cases have −0.9 – 0.7 mm deviations. Two possible serious errors were found: 1) A 4 cm isocenter shift for the PA beam of an AP-PA pair, under-dosing a portion of PTV by 25%. 2) Delivery with MLC leaves abutted behind the jaws as opposed to the midline as planned, leading to a under-dosing of a small volume of the PTV by 25%, by just the boost plan. Due to their error origin, neither of these errors could have been detected by pre-treatment verification. Conclusion: Performing Trajectory Log file analysis could catch typically undetected errors to avoid potentially adverse incidents.« less
Munderi, Paula; Kityo, Cissy; Reid, Andrew; Katabira, Elly; Goodall, Ruth L.; Grosskurth, Heiner; Mugyenyi, Peter; Hakim, James; Gibb, Diana M.
2013-01-01
Background In low-income countries, viral load (VL) monitoring of antiretroviral therapy (ART) is rarely available in the public sector for HIV-infected adults or children. Using clinical failure alone to identify first-line ART failure and trigger regimen switch may result in unnecessary use of costly second-line therapy. Our objective was to identify CD4 threshold values to confirm clinically-determined ART failure when VL is unavailable. Methods 3316 HIV-infected Ugandan/Zimbabwean adults were randomised to first-line ART with Clinically-Driven (CDM, CD4s measured but blinded) or routine Laboratory and Clinical Monitoring (LCM, 12-weekly CD4s) in the DART trial. CD4 at switch and ART failure criteria (new/recurrent WHO 4, single/multiple WHO 3 event; LCM: CD4<100 cells/mm3) were reviewed in 361 LCM, 314 CDM participants who switched over median 5 years follow-up. Retrospective VLs were available in 368 (55%) participants. Results Overall, 265/361 (73%) LCM participants failed with CD4<100 cells/mm3; only 7 (2%) switched with CD4≥250 cells/mm3, four switches triggered by WHO events. Without CD4 monitoring, 207/314 (66%) CDM participants failed with WHO 4 events, and 77(25%)/30(10%) with single/multiple WHO 3 events. Failure/switching with single WHO 3 events was more likely with CD4≥250 cells/mm3 (28/77; 36%) (p = 0.0002). CD4 monitoring reduced switching with viral suppression: 23/187 (12%) LCM versus 49/181 (27%) CDM had VL<400 copies/ml at failure/switch (p<0.0001). Amongst CDM participants with CD4<250 cells/mm3 only 11/133 (8%) had VL<400copies/ml, compared with 38/48 (79%) with CD4≥250 cells/mm3 (p<0.0001). Conclusion Multiple, but not single, WHO 3 events predicted first-line ART failure. A CD4 threshold ‘tiebreaker’ of ≥250 cells/mm3 for clinically-monitored patients failing first-line could identify ∼80% with VL<400 copies/ml, who are unlikely to benefit from second-line. Targeting CD4s to single WHO stage 3 ‘clinical failures’ would particularly avoid premature, costly switch to second-line ART. PMID:23437399
Detection of precursory deformation using a TLS. Application to spatial prediction of rockfalls.
NASA Astrophysics Data System (ADS)
Abellán, Antonio; Vilaplana, Joan Manuel; Calvet, Jaume; Rodriguez, Xavier
2010-05-01
Different applications on the use of Terrestrial Laser Scanner (TLS) on rock slopes are undergoing rapid development, mainly in the characterization of 3D discontinuities and the monitoring of rock slopes. The emphasis of this research is on detection of precursory deformation and its application to spatial prediction of rockfalls. The pilot study area corresponds to the main scarp of an old slide located at Puigcercós (Catalonia, Spain). 3D temporal variations of the terrain were analyzed by comparing sequential TLS datasets. Five areas characterized by centimetric precursory deformations were detected in the study area. Of these deformations, (a) growing deformation across three areas culminated in a rockfall occurrence; and (b) another growing deformation across two areas was detected, making a subsequent rockfall likely. The areas with precursory deformations detected in Puigcercós showed the following characteristics: (a) a sub-vertical fracture delimiting the moving part from the rest of the slope; (b) an increase in the horizontal displacement upwards, typical of a toppling failure mechanism (Muller 1968; Goodman and Bray, 1976). In addition, decimetric-scale rockfalls were observed in the upper part of the moving areas, which is consistent with the observations of Rosser et al., (2007). TLS ILRIS 3D technical characteristics are as follows: high accuracy (7.2 mm at a range of 50 meters), high angular resolution (e.g. 1 point every few cm), fast data acquisition: 2,500 points/second; broad coverage; high maximum range on natural slopes: ~600m. The single point distances between the surface of reference and the successive data point clouds were computed using a conventional methodology (data vs. reference comparison). The direction of comparison was defined as the normal vector of the rock face at its central part. We focused in the study of the small scale displacements towards the origin of coordinates, which reflect the pre-failure deformation on part of the slope. A nearest neighbour (NN) filtering technique was applied to the RAW datasets (Abellán et al., 2009), enabling the accurate detection of centimetric displacements. The parameters of the precursory deformation correlated with the failure mechanism, lithology and volume of the rockfall: higher values of length and duration of the precursory deformation were found in the toppling failure mechanism, ductile materials and rockfalls that involved considerable volumes. These results are consistent with observations in the literature regarding rockfalls of higher magnitude and lower frequency (e.g.: Zvelebil and Moser, 2001; Crosta and Agliardi, 2004; Hungr et al., 2007). It is also important to mention that no precursory indicators were detected prior to each rockfall that occurred in the study areas. This could simply be due to infrequent data acquisition or insufficient instrument accuracy. The application of TLS for the spatial prediction of rockfalls should be validated through: (a) the continuation of the TLS monitoring campaign at the areas which currently show ongoing deformation; (b) the selection of new case studies at different geomorphological sites with different lithologies; and (c) the selection of new case studies with different failure mechanisms (e.g. fall, slide). These tasks are of paramount importance to understand the pre-failure behaviour of rockfalls and to implement these findings in an early warning system.
Patel, Amit R; Alton, Timothy B; Bransford, Richard J; Lee, Michael J; Bellabarba, Carlo B; Chapman, Jens R
2014-02-01
Spinal epidural abscess (SEA) is a rare, serious and increasingly frequent diagnosis. Ideal management (medical vs. surgical) remains controversial. The purpose of this study is to assess the impact of risk factors, organisms, location and extent of SEA on neurologic outcome after medical management or surgery in combination with medical management. Retrospective electronic medical record (EMR) review. We included 128 consecutive, spontaneous SEA from a single tertiary medical center, from January 2005 to September 11. There were 79 male and 49 female with a mean age of 52.9 years (range, 22-83). Patient demographics, presenting complaints, radiographic features, pre/post-treatment neurologic status (ASIA motor score [MS] 0-100), treatment (medical vs. surgical) and clinical follow-up were recorded. Neurologic status was determined before treatment and at last available clinical encounter. Imaging studies reviewed location/extent of pathology. Inclusion criteria were a diagnosis of a bacterial SEA based on radiographs and/or intraoperative findings, age greater than 18 years, and adequate EMR. Exclusion criteria were postinterventional infections, Pott's disease, isolated discitis/osteomyelitis, treatment initiated at an outside facility, and imaging suggestive of a SEA but negative intraoperative findings/cultures. The mean follow-up was 241 days. The presenting chief complaint was site-specific pain (100%), subjective fevers (50%), and weakness (47%). In this cohort, 54.7% had lumbar, 39.1% thoracic, 35.9% cervical, and 23.4% sacral involvement spanning an average of 3.85 disc levels. There were 36% ventral, 41% dorsal, and 23% circumferential infections. Risk factors included a history of IV drug abuse (39.1%), diabetes mellitus (21.9%), and no risk factors (22.7%). Pathogens were methicillin-sensitive Staphylococcus aureus (40%) and methicillin-resistance S aureus (30%). Location, SEA extent, and pathogen did not impact MS recovery. Fifty-one patients were treated with antibiotics alone (group 1), 77 with surgery and antibiotics (group 2). Within group 1, 21 patients (41%) failed medical management (progressive MS loss or worsening pain) requiring delayed surgery (group 3). Irrespective of treatment, MS improved by 3.37 points. Thirty patients had successful medical management (MS: pretreatment, 96.5; post-treatment, 96.8). Twenty-one patients failed medical therapy (41%; MS: pretreatment, 99.86, decreasing to 76.2 [mean change, -23.67 points], postoperative improvement to 85.0; net deterioration, -14.86 points). This is significantly worse than the mean improvement of immediate surgery (group 2; MS: pretreatment, 80.32; post-treatment, 89.84; recovery, 9.52 points). Diabetes mellitus, C-reactive protein greater than 115, white blood count greater than 12.5, and positive blood cultures predict medical failure: None of four parameters, 8.3% failure; one parameter, 35.4% failure; two parameters, 40.2% failure; and three or more parameters, 76.9% failure. Early surgery improves neurologic outcomes compared with surgical treatment delayed by a trial of medical management. More than 41% of patients treated medically failed management and required surgical decompression. Diabetes, C-reactive protein greater than 115, white blood count greater than 12.5, and bacteremia predict failure of medical management. If a SEA is to be treated medically, great caution and vigilance must be maintained. Otherwise, early surgical decompression, irrigation, and debridement should be the mainstay of treatment. Copyright © 2014 Elsevier Inc. All rights reserved.
Multi-spectral investigation of bulk and facet failures in high-power single emitters at 980 nm
NASA Astrophysics Data System (ADS)
Yanson, Dan; Levy, Moshe; Shamay, Moshe; Cohen, Shalom; Shkedy, Lior; Berk, Yuri; Tessler, Renana; Klumel, Genadi; Rappaport, Noam; Karni, Yoram
2013-03-01
Reliable single emitters delivering >10W in the 9xx nm spectral range, are common building blocks for fiber laser pumps. As facet passivation techniques can suppress or delay catastrophic optical mirror damage (COMD) extending emitter reliability into hundreds of thousands of hours, other, less dominant, failure modes such as intra-chip catastrophic optical bulk damage (COBD) become apparent. Based on our failure statistics in high current operation, only ~52% of all failures can be attributed to COMD. Imaging through a window opened in the metallization on the substrate (n) side of a p-side down mounted emitter provides valuable insight into both COMD and COBD failure mechanisms. We developed a laser ablation process to define a window on the n-side of an InGaAs/AlGaAs 980nm single emitter that is overlaid on the pumped 90μm stripe on the p-side. The ablation process is compatible with the chip wire-bonding, enabling the device to be operated at high currents with high injection uniformity. We analyzed both COMD and COBD failed emitters in the electroluminescence and mid-IR domains supported by FIB/SEM observation. The ablated devices revealed branching dark line patterns, with a line origin either at the facet center (COMD case) or near the stripe edge away from the facet (COBD case). In both cases, the branching direction is always toward the rear facet (against the photon density gradient), with SEM images revealing a disordered active layer structure. Absorption levels between 0.22eV - 0.55eV were observed in disordered regions by FT-IR spectroscopy. Temperature mapping of a single emitter in the MWIR domain was performed using an InSb detector. We also report an electroluminescence study of a single emitter just before and after failure.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhou, Guowei; Sun, Qingping; Zeng, Danielle
In current work, unidirectional (UD) carbon fiber composite hatsection component with two different layups are studied under dynamic 3 point bending loading. The experiments are performed at various impact velocities, and the effects of impactor velocity and layup on acceleration histories are compared. A macro model is established with LS-Dyna for more detailed study. The simulation results show that the delamination plays an important role during dynamic 3 point bending test. Based on the analysis with high speed camera, the sidewall of hatsection shows significant buckling rather than failure. Without considering the delamination, current material model cannot capture the postmore » failure phenomenon correctly. The sidewall delamination is modeled by assumption of larger failure strain together with slim parameters, and the simulation results of different impact velocities and layups match the experimental results reasonable well.« less
Krieger, Oliver; Matuliene, Giedre; Hüsler, Jürg; Salvi, Giovanni E; Pjetursson, Bjarni; Brägger, Urs
2009-08-01
To assess retrospectively, over at least 5 years, the incidences of technical and biological complications and failures in young adult patients with birth defects affecting the formation of teeth. All insurance cases with a birth defect that had crowns and fixed dental prostheses (FDPs) inserted more than 5 years ago were contacted and asked to participate in a reexamination. The median age of the patients was 19.3 years (range 16.6-24.7 years) when prosthetic treatment was initiated. Over the median observation period of 15.7 years (range 7.4-24.9 years) and considering the treatment needs at the reexamination, 19 out of 33 patients (58%) with reconstructions on teeth remained free from all failures or complications. From the patients with FDPs and single unit crowns (SCs) on implants followed over a median observation period of 8 years (range 4.6-15.3 years), eight out of 17% or 47% needed a retreatment or repair at some point due to a failure or a complication. From the three groups of patients, the cases with amelogenesis/dentinogenesis imperfecta demonstrated the highest failure and complication rates. In the cases with cleft lip, alveolus and palate (CLAP) or hypodontia/oligodontia, 71% of the SCs and 73% of the FDPs on teeth (FDP T) remained complication free over a median observation period of about 16 years. Sixty-two percent of the SCs and 64% of the FDPs on implants remained complication free over 8 years. Complications occurred earlier with implant-supported reconstructions. Because healthy, pristine teeth can be left unprepared, implant-supported SCs and FDPs are the treatment choice in young adults with birth defects resulting in tooth agenesis and in whom the edentulous spaces cannot be closed by means of orthodontic therapy. However, the trend for earlier and more frequent complications with implant-supported reconstructions in young adults, expecting many years of function with the reconstructions, has to be weighed against the benefits of keeping teeth unprepared. In cases with CLAP in which anatomical conditions render implant placement difficult and in which teeth adjacent to the cleft require esthetic corrections, the conventional FDP T still remains the treatment of choice.
Zanoni, R G; Bugnon, Ph; Deranleau, E; Nguyen, T M V; Brügger, D
2010-12-01
Data of 13'469 blood samples from 10'999 dogs and 2'470 cats tested for rabies neutralizing antibodies within the framework of pet travel schemes were analysed for single and combined factors influencing antibody titres and failures. The time span between vaccination and drawing the blood sample was confirmed as a major source of failure in dogs with a proportion of 23 % at 4 months after primary vaccination (single dose). Failures in dogs and cats (titre < 0.5 IU) were significantly reduced after double primary vaccination (2 doses within 7 - 10 days), although failures reached comparable levels in dogs as early as 6 months after vaccination. In contrast, failure after vaccination was generally below 5 % in dogs and absent in cats after a booster applied at earliest 12 months after single primary vaccination. Statistically significant differences between the failures of the vaccine brands «Rabisin» (1.5 %), «Defensor» (6.7 %), «Nobivac Rabies» (11.0 %) and «Rabdomun» (18.2 %) were found in dogs but also between the titres induced in cats. Significant differences were found between different dog breeds with some small breeds showing a significantly higher responsiveness. Taken together, a new regimen for rabies vaccination consisting of double primary vaccination with a short interval of 7 - 10 days and a one-year booster appears to be highly recommended for dogs and cats.
Single living predicts a higher mortality in both women and men with chronic heart failure.
Mard, Shan; Nielsen, Finn Erland
2016-09-01
We examined the impact of single living on all-cause mortality in patients with chronic heart failure and determined if this association was modified by gender. This historical cohort study included 637 patients who were admitted to the Department of Cardiology, Herlev Hospital, Denmark, between 1 July 2005 and 30 June 2007. Baseline clinical data were obtained from patient records. Data on survival rates were obtained from the Danish Civil Registration System. Cox proportional hazard analysis was used to compute the hazard ratio (HR) of all-cause mortality, controlling for confounding factors. The median follow-up time was 2.8 years. A total of 323 (50.7%) patients died during the follow-up period. After adjustment for confounding factors, risk of death was associated with being single (HR = 1.53 (95% confidence interval: 1.19-1.96)). In a gender-stratified analysis, the risk of death did not differ among single-living women and men. Single living is a prognostic determinant of all-cause mortality in men and women with chronic heart failure. none. not relevant.
Abel, Alexandra AI
2018-05-16
The 20th Annual Autumn Meeting of the British Society for Heart Failure took place on the 23-24 November 2017 at the Queen Elizabeth II Conference Centre, London, UK. Over 800 delegates were in attendance: a multidisciplinary league of professionals who treat patients with heart failure, including specialist nurses, trainees, cardiologists, geriatricians, pharmacists and general practitioners. The theme of the conference was 'three decades of heart failure' and celebrated the success of modern heart failure management. This report highlights the 'three decades' session, the clinical trials update, and the main discussion points from heart failure question time.
China, Louise; Muirhead, Nicola; Skene, Simon S; Shabir, Zainib; De Maeyer, Roel P H; Maini, Alexander A N; Gilroy, Derek W; O'Brien, Alastair J
2016-01-25
Circulating prostaglandin E2 levels are elevated in acutely decompensated cirrhosis and have been shown to contribute to immune suppression. Albumin binds and inactivates this hormone. Human albumin solution could thus be repurposed as an immune restorative drug in these patients.This feasibility study aims to determine whether it is possible and safe to restore serum albumin to >30 g/L and maintain it at this level in patients admitted with acute decompensated cirrhosis using repeated 20% human albumin infusions according to daily serum albumin levels. Albumin To prevenT Infection in chronic liveR failurE (ATTIRE) stage 1 is a multicentre, open label dose feasibility trial. Patients with acutely decompensated cirrhosis admitted to hospital with a serum albumin of <30 g/L are eligible, subject to exclusion criteria. Daily intravenous human albumin solution will be infused, according to serum albumin levels, for up to 14 days or discharge in all patients. The primary end point is daily serum albumin levels for the duration of the treatment period and the secondary end point is plasma-induced macrophage dysfunction. The trial will recruit 80 patients. Outcomes will be used to assist with study design for an 866 patient randomised controlled trial at more than 30 sites across the UK. Research ethics approval was given by the London-Brent research ethics committee (ref: 15/LO/0104). The clinical trials authorisation was issued by the medicines and healthcare products regulatory agency (ref: 20363/0350/001-0001). Will be disseminated through peer reviewed journals and international conferences. Recruitment of the first participant occurred on 26/05/2015. The trial is registered with the European Medicines Agency (EudraCT 2014-002300-24) and has been adopted by the NIHR (ISRCTN 14174793). This manuscript refers to V.4.0 of the protocol; Pre-results. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
NASA Astrophysics Data System (ADS)
Roirand, Q.; Missoum-Benziane, D.; Thionnet, A.; Laiarinandrasana, L.
2017-09-01
Textile composites are composed of 3D complex architecture. To assess the durability of such engineering structures, the failure mechanisms must be highlighted. Examinations of the degradation have been carried out thanks to tomography. The present work addresses a numerical damage model dedicated to the simulation of the crack initiation and propagation at the scale of the warp yarns. For the 3D woven composites under study, loadings in tension and combined tension and bending were considered. Based on an erosion procedure of broken elements, the failure mechanisms have been modelled on 3D periodic cells by finite element calculations. The breakage of one element was determined using a failure criterion at the mesoscopic scale based on the yarn stress at failure. The results were found to be in good agreement with the experimental data for the two kinds of macroscopic loadings. The deterministic approach assumed a homogeneously distributed stress at failure all over the integration points in the meshes of woven composites. A stochastic approach was applied to a simple representative elementary periodic cell. The distribution of the Weibull stress at failure was assigned to the integration points using a Monte Carlo simulation. It was shown that this stochastic approach allowed more realistic failure simulations avoiding the idealised symmetry due to the deterministic modelling. In particular, the stochastic simulations performed have shown several variations of the stress as well as strain at failure and the failure modes of the yarn.
Structural Reliability Analysis and Optimization: Use of Approximations
NASA Technical Reports Server (NTRS)
Grandhi, Ramana V.; Wang, Liping
1999-01-01
This report is intended for the demonstration of function approximation concepts and their applicability in reliability analysis and design. Particularly, approximations in the calculation of the safety index, failure probability and structural optimization (modification of design variables) are developed. With this scope in mind, extensive details on probability theory are avoided. Definitions relevant to the stated objectives have been taken from standard text books. The idea of function approximations is to minimize the repetitive use of computationally intensive calculations by replacing them with simpler closed-form equations, which could be nonlinear. Typically, the approximations provide good accuracy around the points where they are constructed, and they need to be periodically updated to extend their utility. There are approximations in calculating the failure probability of a limit state function. The first one, which is most commonly discussed, is how the limit state is approximated at the design point. Most of the time this could be a first-order Taylor series expansion, also known as the First Order Reliability Method (FORM), or a second-order Taylor series expansion (paraboloid), also known as the Second Order Reliability Method (SORM). From the computational procedure point of view, this step comes after the design point identification; however, the order of approximation for the probability of failure calculation is discussed first, and it is denoted by either FORM or SORM. The other approximation of interest is how the design point, or the most probable failure point (MPP), is identified. For iteratively finding this point, again the limit state is approximated. The accuracy and efficiency of the approximations make the search process quite practical for analysis intensive approaches such as the finite element methods; therefore, the crux of this research is to develop excellent approximations for MPP identification and also different approximations including the higher-order reliability methods (HORM) for representing the failure surface. This report is divided into several parts to emphasize different segments of the structural reliability analysis and design. Broadly, it consists of mathematical foundations, methods and applications. Chapter I discusses the fundamental definitions of the probability theory, which are mostly available in standard text books. Probability density function descriptions relevant to this work are addressed. In Chapter 2, the concept and utility of function approximation are discussed for a general application in engineering analysis. Various forms of function representations and the latest developments in nonlinear adaptive approximations are presented with comparison studies. Research work accomplished in reliability analysis is presented in Chapter 3. First, the definition of safety index and most probable point of failure are introduced. Efficient ways of computing the safety index with a fewer number of iterations is emphasized. In chapter 4, the probability of failure prediction is presented using first-order, second-order and higher-order methods. System reliability methods are discussed in chapter 5. Chapter 6 presents optimization techniques for the modification and redistribution of structural sizes for improving the structural reliability. The report also contains several appendices on probability parameters.
Modeling of a bubble-memory organization with self-checking translators to achieve high reliability.
NASA Technical Reports Server (NTRS)
Bouricius, W. G.; Carter, W. C.; Hsieh, E. P.; Wadia, A. B.; Jessep, D. C., Jr.
1973-01-01
Study of the design and modeling of a highly reliable bubble-memory system that has the capabilities of: (1) correcting a single 16-adjacent bit-group error resulting from failures in a single basic storage module (BSM), and (2) detecting with a probability greater than 0.99 any double errors resulting from failures in BSM's. The results of the study justify the design philosophy adopted of employing memory data encoding and a translator to correct single group errors and detect double group errors to enhance the overall system reliability.
Combination Space Station Handrail Clamp and Pointing Device
NASA Technical Reports Server (NTRS)
Hughes, Stephen J. (Inventor)
1999-01-01
A device for attaching an experiment carrier to a space station handrail is provided. The device has two major components, a clamping mechanism for attachment to a space station handrail, and a pointing carrier on which an experiment package can be mounted and oriented. The handrail clamp uses an overcenter mechanism and the carrier mechanism uses an adjustable preload ball and socket for carrier positioning. The handrail clamp uses a stack of disk springs to provide a spring loaded button. This configuration provides consistent clamping force over a range of possible handrail thicknesses. Three load points are incorporated in the clamping mechanism thereby spreading the clamping load onto three separate points on the handrail. A four bar linkage is used to provide for a single actuation lever for all three load points. For additional safety, a secondary lock consisting of a capture plate and push lock keeps the clamp attached to the handrail in the event of main clamp failure. For the carrier positioning mechanism, a ball in a spring loaded socket uses friction to provide locking torque; however. the ball and socket are torque limited so that the ball ran slip under kick loads (125 pounds or greater). A lead screw attached to disk spring stacks is used to provide an adjustable spring force on the socket. A locking knob is attached to the lead screw to allow for hand manipulation of the lead screw.
Noyes, Matthew P; Lederman, Evan; Adams, Christopher R; Denard, Patrick J
2018-05-01
To compare the biomechanical properties of single-row repair with triple-loaded (TL) anchor repair versus a knotless rip stop (KRS) repair in a rotator cuff repair model. Rotator cuff tears were created in 8 cadaveric matched-pair specimens and repaired with a TL anchor or KRS construct. In the TL construct, anchors were placed in the greater tuberosity and then all suture limbs were passed through the rotator cuff as simple sutures and tied. In the KRS construct, a 2-mm suture tape was passed through the tendon in an inverted mattress fashion, and a free suture was passed medial to the suture tape to create a rip-stop. Then, the suture tape and free suture were secured with knotless anchors. Displacement was observed with video tracking after cyclic loading, and specimens were loaded to failure. The mean load to failure was 438 ± 59 N in TL anchor repairs compared with 457 ± 110 N in KRS repairs (P = .582). The mean displacement with cyclic loading was 3.8 ± 1.6 mm in TL anchor repairs versus 4.3 ± 1.8 mm in the KRS group (P = .297). Mode of failure was consistent in both groups, with 6 of 8 failures in the TL anchor group and 7 of 8 failures in KRS group occurring from anchor pullout. There is no statistical difference in load to failure and cyclic loading between TL anchor and KRS single-row repair techniques. KRS repair technique may be an alternative method of repairing full-thickness supraspinatus tendon tears with a single-row construct. Copyright © 2018 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Lovelock, D Michael; Zhang, Zhigang; Jackson, Andrew; Keam, Jennifer; Bekelman, Justin; Bilsky, Mark; Lis, Eric; Yamada, Yoshiya
2010-07-15
In the setting of high-dose single-fraction image-guided radiotherapy of spine metastases, the delivered dose is hypothesized to be a significant factor in local control. We investigated the dependence of local control on measures of dose insufficiency. The minimum doses received by the hottest 100%, 98%, and 95% (D(min), D(98), and D(95)) of the gross target volume (GTV) were computed for 91 consecutively treated lesions observed in 79 patients. Prescribed doses of 18-24 Gy were delivered in a single fraction. The spinal cord and cauda equina were constrained to a maximum dose of 12-14 Gy and 16 Gy, respectively. A rank-sum test was used to assess the differences between radiographic local failure and local control. With a median follow-up of 18 months, seven local failures have occurred. The distributions of GTV D(min), D(98), and D(95) for treatments resulting in local failure were found to be statistically different from the corresponding distributions of the patient group as a whole. Taking no account of histology, p values calculated for D(min), D(98), and D(95) were 0.004, 0.012, and 0.031, respectively. No correlations between local failure and target volume or between local failure and anatomic location were found. The results indicate that D(min), D(98), and D(95) may be important risk factors for local failure. No local failures in any histology were observed when D(min) was >15 Gy, suggesting that this metric may be an important predictor of local control. Copyright 2010 Elsevier Inc. All rights reserved.
Lovelock, D. Michael; Zhang, Zhigang; Jackson, Andrew; Keam, Jennifer; Bekelman, Justin; Bilsky, Mark; Lis, Eric; Yamada, Yoshiya
2011-01-01
Purpose In the setting of high-dose single-fraction image-guided radiotherapy of spine metastases, the delivered dose is hypothesized to be a significant factor in local control. We investigated the dependence of local control on measures of dose insufficiency. Methods and Materials The minimum doses received by the hottest 100%, 98%, and 95% (Dmin, D98, and D95) of the gross target volume (GTV) were computed for 91 consecutively treated lesions observed in 79 patients. Prescribed doses of 18–24 Gy were delivered in a single fraction. The spinal cord and cauda equina were constrained to a maximum dose of 12–14 Gy and 16 Gy, respectively. A rank-sum test was used to assess the differences between radiographic local failure and local control. Results With a median follow-up of 18 months, seven local failures have occurred. The distributions of GTV Dmin, D98, and D95 for treatments resulting in local failure were found to be statistically different from the corresponding distributions of the patient group as a whole. Taking no account of histology, p values calculated for Dmin, D98, and D95 were 0.004, 0.012, and 0.031, respectively. No correlations between local failure and target volume or between local failure and anatomic location were found. Conclusions The results indicate that Dmin, D98, and D95 may be important risk factors for local failure. No local failures in any histology were observed when Dmin was >15 Gy, suggesting that this metric may be an important predictor of local control. PMID:20350795
Lu, Junjie; Baccei, Anna; Lummertz da Rocha, Edroaldo; Guillermier, Christelle; McManus, Sean; Finney, Lydia A; Zhang, Cheng; Steinhauser, Matthew L; Li, Hu; Lerou, Paul H
2018-04-01
Differentiation of human pluripotent stem cells towards definitive endoderm (DE) is the critical first step for generating cells comprising organs such as the gut, liver, pancreas and lung. This in-vitro differentiation process generates a heterogeneous population with a proportion of cells failing to differentiate properly and maintaining expression of pluripotency factors such as Oct4. RNA sequencing of single cells collected at four time points during a 4-day DE differentiation identified high expression of metallothionein genes in the residual Oct4-positive cells that failed to differentiate to DE. Using X-ray fluorescence microscopy and multi-isotope mass spectrometry, we discovered that high intracellular zinc level corresponds with persistent Oct4 expression and failure to differentiate. This study improves our understanding of the cellular heterogeneity during in-vitro directed differentiation and provides a valuable resource to improve DE differentiation efficiency. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.
Bell theorem without inequalities for two spinless particles
NASA Astrophysics Data System (ADS)
Bernstein, Herbert J.; Greenberger, Daniel M.; Horne, Michael A.; Zeilinger, Anton
1993-01-01
We use the Greenberger-Horne-Zeilinger [in Bell's Theorem, Quantum Theory,and Conceptions of the Universe, edited by M. Kafatos (Kluwer Academic, Dordrecht, 1989)] approach to present three demonstrations of the failure of Einstein-Podolsky-Rosen (EPR) [Phys. Rev. 47, 777 (1935)] local realism for the case of two spinless particles in a two-particle interferometer. The original EPR assumptions of locality and reality do not suffice for this. First, we use the EPR assumptions of locality and reality to establish that in a two-particle interferometer, the path taken by each particle is an element of reality. Second, we supplement the EPR premises by the postulate that when the path taken by a particle is an element of reality, all paths not taken are empty. We emphasize that our approach is not applicable to a single-particle interferometer because there the path taken by the particle cannot be established as an element of reality. We point out that there are real conceptual differences between single-particle, two-particle, and multiparticle interferometry.
Therapeutic progress in amyotrophic lateral sclerosis-beginning to learning.
Kumar, Vijay; Islam, Asimul; Hassan, Md Imtaiyaz; Ahmad, Faizan
2016-10-04
Amyotrophic lateral sclerosis (ALS) is a fatal neurodegenerative disease associated with motor neuron degeneration, muscle weakness, paralysis and finally death. The proposed mechanisms of ALS include glutamate excitotoxicity, oxidative stress, inflammation, mitochondrial dysfunction, apoptosis and proteasomal dysfunction. Although numerous pathological mechanisms have been explained, ALS remains incurable disease because of failure of clinical trials and lack of any effective therapy. The rapid advancement in genetic discoveries in ALS emphasizes the point that ALS is a multi-subtype syndrome rather than a single disease. This can be argued as one of the single reason why many previous therapeutic drug trials have failed. Efforts to develop novel ALS treatments which target specific pathomechanisms are currently being pursued. Herein, we review the recent discovery and preclinical characterization of neuroprotective compounds and compare their effects on disease onset, duration and survival. Furthermore, the structure-activity relationships of these agents are analyzed with the overall goal of developing a screening strategy for future clinical applications. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
Educating from Failure: Dewey's Aesthetics and the Case for Failure in Educational Theory
ERIC Educational Resources Information Center
Stoller, Aaron
2013-01-01
This essay is an attempt to add to the argument that beauty matters in education through offering a reciprocal but interconnected point: if the dynamic harmony and deep connectedness of beauty need to be taken seriously, so must their aesthetic converse--the disharmony and estrangement of failure. While the discourse of philosophical aesthetics…
Development of Improved Printed Wiring Board Inner Layer Adhesion.
1982-06-01
24722-49 A Oak-Atlantic 2048 Cohesive Failure in "C" Stage B Oak-Atlantic 1990 Cohesive Failure in "C" Stage C Mica 2018 Cohesive Failure In "C" Stage D...allowable resistance between test points for all IR measurements was 500 megohms. The results showed no blistering, measling , crazing or delaminatin due
Plastic deformation in nanoscale gold single crystals and open-celled nanoporous gold
NASA Astrophysics Data System (ADS)
Lee, Dongyun; Wei, Xiaoding; Zhao, Manhong; Chen, Xi; Jun, Seong C.; Hone, James; Kysar, Jeffrey W.
2007-01-01
The results of two sets of experiments to measure the elastic-plastic behaviour of gold at the nanometre length scale are reported. One set of experiments was on free-standing nanoscale single crystals of gold, and the other was on free-standing nanoscale specimens of open-celled nanoporous gold. Both types of specimens were fabricated from commercially available leaf which was either pure Au or a Au/Ag alloy following by dealloying of the Ag. Mechanical testing specimens of a 'dog-bone' shape were fabricated from the leaf using standard lithographic procedures after the leaf had been glued onto a silicon wafer. The thickness of the gauge portion of the specimens was about 100 nm, the width between 250 nm and 300 nm and the length 7 µm. The specimens were mechanically loaded with a nanoindenter (MTS) at the approximate midpoint of the gauge length. The resulting force-displacement curve of the single crystal gold was serrated and it was evident that slip localization occurred on individual slip systems; however, the early stages of the plastic deformation occurred in a non-localized manner. The results of detailed finite element analyses of the specimen suggest that the critical resolved shear stress of the gold single crystal was as high as 135 MPa which would lead to a maximum uniaxial stress of about 500 MPa after several per cent strain. The behaviour of the nanoporous gold was substantially different. It exhibited an apparent elastic behaviour until the point where it failed in an apparently brittle manner, although it is assumed that plastic deformation occurred in the ligaments prior to failure. The average elastic stiffness of three specimens was measured to be Enp = 8.8 GPa and the stress at ultimate failure averaged 190 MPa for the three specimens tested. Scaling arguments suggest that the stress in the individual ligaments could approach the theoretical shear strength. Presented at the IUTAM Symposium on Plasticity at the Micron Scale, Technical University of Denmark, Copenhagen, Denmark.
Kim, H-I; Park, M S; Song, K J; Woo, Y; Hyung, W J
2014-10-01
The learning curve of robotic gastrectomy has not yet been evaluated in comparison with the laparoscopic approach. We compared the learning curves of robotic gastrectomy and laparoscopic gastrectomy based on operation time and surgical success. We analyzed 172 robotic and 481 laparoscopic distal gastrectomies performed by single surgeon from May 2003 to April 2009. The operation time was analyzed using a moving average and non-linear regression analysis. Surgical success was evaluated by a cumulative sum plot with a target failure rate of 10%. Surgical failure was defined as laparoscopic or open conversion, insufficient lymph node harvest for staging, resection margin involvement, postoperative morbidity, and mortality. Moving average and non-linear regression analyses indicated stable state for operation time at 95 and 121 cases in robotic gastrectomy, and 270 and 262 cases in laparoscopic gastrectomy, respectively. The cumulative sum plot identified no cut-off point for surgical success in robotic gastrectomy and 80 cases in laparoscopic gastrectomy. Excluding the initial 148 laparoscopic gastrectomies that were performed before the first robotic gastrectomy, the two groups showed similar number of cases to reach steady state in operation time, and showed no cut-off point in analysis of surgical success. The experience of laparoscopic surgery could affect the learning process of robotic gastrectomy. An experienced laparoscopic surgeon requires fewer cases of robotic gastrectomy to reach steady state. Moreover, the surgical outcomes of robotic gastrectomy were satisfactory. Copyright © 2013 Elsevier Ltd. All rights reserved.
People with heart failure and home health care resource use and outcomes.
Madigan, Elizabeth A
2008-04-01
Patients with heart failure represent a common patient population in home health care, yet little is known about their outcomes. Patients with heart failure, regardless of site of care, experience substantial numbers of rehospitalisations in the United States. Home health care is a common postacute care service for patients with heart failure. Retrospective analysis. The study employed a large administrative data base from 2003 - the Outcomes and Assessment Information Set, which is required for all US Medicare and Medicaid patients receiving home health care. There were 145 191 patients with a primary diagnosis of heart failure represented in the data set. The outcomes of interest were the trajectory of care (point of entry and discharge from home health care), hospitalisation, length of stay and change in functional status. Almost three-quarters (73.9%) of patients entered home health care following a hospital stay. Nearly two-thirds (64%) remained at home at discharge from home health care. Approximately 15% of patients are hospitalised during the home health care episode, most often for symptoms consistent with exacerbation of the heart failure, if a reason could be identified. The average length of stay in home health care was 44 days. There was only a small improvement in functional status: 0.50 points for activities of daily living and 0.57 points for instrumental activities of daily living. Similar small improvement occurred in depressive symptoms, 0.68. There may be room for improvement in these outcomes with more recent evidence that suggests strategies for reducing hospitalisation and improving patient functional status abilities. Yet, the chronic progressive nature of heart failure may also provide a limiting factor in the outcomes that can be attained.
Folsom, Aaron R; Shah, Amil M; Lutsey, Pamela L; Roetker, Nicholas S; Alonso, Alvaro; Avery, Christy L; Miedema, Michael D; Konety, Suma; Chang, Patricia P; Solomon, Scott D
2015-09-01
Many people may underappreciate the role of lifestyle in avoiding heart failure. We estimated whether greater adherence in middle age to American Heart Association's Life's Simple 7 guidelines—on smoking, body mass, physical activity, diet, cholesterol, blood pressure, and glucose—is associated with lower lifetime risk of heart failure and greater preservation of cardiac structure and function in old age. We studied the population-based Atherosclerosis Risk in Communities Study cohort of 13,462 adults ages 45-64 years in 1987-1989. From the 1987-1989 risk factor measurements, we created a Life's Simple 7 score (range 0-14, giving 2 points for ideal, 1 point for intermediate, and 0 points for poor components). We identified 2218 incident heart failure events using surveillance of hospital discharge and death codes through 2011. In addition, in 4855 participants free of clinical cardiovascular disease in 2011-2013, we performed echocardiography from which we quantified left ventricular hypertrophy and diastolic dysfunction. One in four participants (25.5%) developed heart failure through age 85 years. Yet, this lifetime heart failure risk was 14.4% for those with a middle-age Life's Simple 7 score of 10-14 (optimal), 26.8% for a score of 5-9 (average), and 48.6% for a score of 0-4 (inadequate). Among those with no clinical cardiovascular event, the prevalence of left ventricular hypertrophy in late life was approximately 40% as common, and diastolic dysfunction was approximately 60% as common, among those with an optimal middle-age Life's Simple 7 score, compared with an inadequate score. Greater achievement of American Heart Association's Life's Simple 7 in middle age is associated with a lower lifetime occurrence of heart failure and greater preservation of cardiac structure and function. Copyright © 2015 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Abellán, A.; Vilaplana, J. M.; Calvet, J.; García-Sellés, D.; Asensio, E.
2011-03-01
This case study deals with a rock face monitoring in urban areas using a Terrestrial Laser Scanner. The pilot study area is an almost vertical, fifty meter high cliff, on top of which the village of Castellfollit de la Roca is located. Rockfall activity is currently causing a retreat of the rock face, which may endanger the houses located at its edge. TLS datasets consist of high density 3-D point clouds acquired from five stations, nine times in a time span of 22 months (from March 2006 to January 2008). The change detection, i.e. rockfalls, was performed through a sequential comparison of datasets. Two types of mass movement were detected in the monitoring period: (a) detachment of single basaltic columns, with magnitudes below 1.5 m3 and (b) detachment of groups of columns, with magnitudes of 1.5 to 150 m3. Furthermore, the historical record revealed (c) the occurrence of slab failures with magnitudes higher than 150 m3. Displacements of a likely slab failure were measured, suggesting an apparent stationary stage. Even failures are clearly episodic, our results, together with the study of the historical record, enabled us to estimate a mean detachment of material from 46 to 91.5 m3 year-1. The application of TLS considerably improved our understanding of rockfall phenomena in the study area.
NASA Astrophysics Data System (ADS)
Douay, N.
2011-10-01
In the frame of GALILEO In-Orbit Validation program which is composed of 4 satellites, Thales Alenia Space France has designed, developed and tested the Electrical Power Subsystem. Besides some classical design choices like: -50V regulated main power bus provided by the PCDU manufactured by Terma (DK), -Solar array, manufactured by Dutch-Space (NL), using Ga-As triple junction technology from Azur Space Power Solar GmbH, -SAFT (FR) Lithium-ion Battery for which cell package balancing function is required, -Solar Array Drive Mechanism, provided by RUAG Space Switzerland, to transfer the power. This subsystem features a fully autonomous, failure tolerant, battery charge management able to operate even after a complete unavailability of the on-board software. The battery charge management is implemented such that priority is always given to satisfy the satellite main bus needs in order to maintain the main bus regulation under MEA control. This battery charge management principle provides very high reliability and operational robustness. So, the paper describes : -the battery charge management concept using a combination of PCDU hardware and relevant battery lines monitoring, -the functional aspect of the single point failure free S4R (Sequential Switching Shunt Switch Regulator) and associated performances, -the failure modes isolated and passivated by this architecture. The paper will address as well the autonomous balancing function characteristics and performances.
Effects of space radiation on electronic microcircuits
NASA Technical Reports Server (NTRS)
Kolasinski, W. A.
1989-01-01
The single event effects or phenomena (SEP), which so far have been observed as events falling on one or another of the SE classes: Single Event Upset (SEU), Single Event Latchup (SEL) and Single Event Burnout (SEB), are examined. Single event upset is defined as a lasting, reversible change in the state of a multistable (usually bistable) electronic circuit such as a flip-flop or latch. In a computer memory, SEUs manifest themselves as unexplained bit flips. Since latchup is in general caused by a single event of short duration, the single event part of the SEL term is superfluous. Nevertheless, it is used customarily to differentiate latchup due to a single heavy charged particle striking a sensitive cell from more ordinary kinds of latchup. Single event burnout (SEB) refers usually to total instantaneous failure of a power FET when struck by a single particle, with the device shorting out the power supply. An unforeseen failure of these kinds can be catastrophic to a space mission, and the possibilities are discussed.
Readmission for dehydration or renal failure after ileostomy creation.
Paquette, Ian M; Solan, Patrick; Rafferty, Janice F; Ferguson, Martha A; Davis, Bradley R
2013-08-01
Ileostomy creation is a commonly performed operation in colorectal surgery; however, many patients develop complications such as dehydration postoperatively. Dehydration is often severe enough to warrant hospital readmission and may result in renal failure. The true incidence of this complication has not been well described. The aim of this study was to identify the rate of hospital readmission secondary to dehydration or renal failure within 30 days of ileostomy creation. Retrospective review of all patients undergoing ileostomy creation from 2007 to 2011 in a single colorectal practice of 4 surgeons was performed. Charts were reviewed to identify patients readmitted for dehydration or renal failure within 30 days of operation. Data were then analyzed to identify predictors of readmission, dehydration, and renal failure. Subset analysis compared patients readmitted with simple dehydration versus patients with renal failure. Two hundred one patients undergoing colorectal operations that included ileostomy creation within a 4-year period at a single institution for a variety of indications were included. The primary outcome measured was readmission for dehydration or renal failure. We observed a 17% 30-day readmission rate for dehydration or renal failure following ileostomy creation. Age greater than 50 was identified as an independent predictor of readmission with renal failure, whereas IPAA was predictive of readmission for simple dehydration, but not renal failure. Patients admitted with renal failure had significantly longer hospital stays and median hospital charges after readmission in comparison with patients admitted with simple dehydration. This study was limited by its retrospective nature and its limited sample size. Hospital readmission due to dehydration or renal failure following ileostomy creation is common, with age >50 being the strongest predictor for renal failure. Appropriate strategies to decrease dehydration and renal failure following ileostomy creation need to be investigated.
Conceptual phase A design of a cryogenic shutter mechanism for the SAFARI flight instrument
NASA Astrophysics Data System (ADS)
Eigenmann, Max; Wehmeier, Udo J.; Vuilleumier, Aurèle; Messina, Gabriele; Meyer, Michael R.
2012-09-01
We present a conceptual design for a cryogenic optical mechanism for the SAFARI instrument. SAFARI is a long wavelength (34-210 micron) Imaging Fourier Transform Spectrometer (FTS) to fly as an ESA instrument on the JAXA SPICA mission projected to launch in 2021. SPICA is a large 3m class space telescope which will have an operating temperature of less than 7K. The SAFARI shutter is a single point of failure flight mechanism designed to operate in space at a temperature of 4K which meets redundancy and reliability requirements of this challenging mission. The conceptual design is part of a phase A study led by ETH Institute for Astronomy and conducted by RUAG Space AG.
Time delay in Swiss cheese gravitational lensing
NASA Astrophysics Data System (ADS)
Chen, B.; Kantowski, R.; Dai, X.
2010-08-01
We compute time delays for gravitational lensing in a flat Λ dominated cold dark matter Swiss cheese universe. We assume a primary and secondary pair of light rays are deflected by a single point mass condensation described by a Kottler metric (Schwarzschild with Λ) embedded in an otherwise homogeneous cosmology. We find that the cosmological constant’s effect on the difference in arrival times is nonlinear and at most around 0.002% for a large cluster lens; however, we find differences from time delays predicted by conventional linear lensing theory that can reach ˜4% for these large lenses. The differences in predicted delay times are due to the failure of conventional lensing to incorporate the lensing mass into the mean mass density of the universe.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, B.; Kantowski, R.; Dai, X.
We compute time delays for gravitational lensing in a flat {Lambda} dominated cold dark matter Swiss cheese universe. We assume a primary and secondary pair of light rays are deflected by a single point mass condensation described by a Kottler metric (Schwarzschild with {Lambda}) embedded in an otherwise homogeneous cosmology. We find that the cosmological constant's effect on the difference in arrival times is nonlinear and at most around 0.002% for a large cluster lens; however, we find differences from time delays predicted by conventional linear lensing theory that can reach {approx}4% for these large lenses. The differences in predictedmore » delay times are due to the failure of conventional lensing to incorporate the lensing mass into the mean mass density of the universe.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shaikh, S.; Gill, M.; Collier, D.A.
1994-03-15
We report the results of a linkage study in 24 families multiply affected with schizophrenia using a polymorphic DNA sequence encoding the third cytoplasmic loop of the dopamine D4 receptor. Two-point LOD score analyses with a range of single gene models ranging from near dominant to near recessive revealed no evidence for linkage. In addition, we examined the data by non-parametric sib-pair analysis and found no excess sharing of alleles between affected sib-pairs. We therefore conclude that mutations within the dopamine D4 receptor gene do not have a major aetiological role in schizophrenia in our collection of pedigrees. 20 refs.,more » 2 tabs.« less
Fault-Tolerant Local-Area Network
NASA Technical Reports Server (NTRS)
Morales, Sergio; Friedman, Gary L.
1988-01-01
Local-area network (LAN) for computers prevents single-point failure from interrupting communication between nodes of network. Includes two complete cables, LAN 1 and LAN 2. Microprocessor-based slave switches link cables to network-node devices as work stations, print servers, and file servers. Slave switches respond to commands from master switch, connecting nodes to two cable networks or disconnecting them so they are completely isolated. System monitor and control computer (SMC) acts as gateway, allowing nodes on either cable to communicate with each other and ensuring that LAN 1 and LAN 2 are fully used when functioning properly. Network monitors and controls itself, automatically routes traffic for efficient use of resources, and isolates and corrects its own faults, with potential dramatic reduction in time out of service.
Figures of Merit for Aeronautics Programs and Addition to NASA LARC Fire Station
NASA Technical Reports Server (NTRS)
Harper, Belinda M.
1995-01-01
This report accounts details of two research projects for the Langley Aerospace Research Summer Scholars (LARSS) program. The first project, with the Office of Mission Assurance, involved subjectively predicting the probable success of two aeronautics programs by means of a tool called a Figure of Merit. The figure of merit bases program success on the quality and reliability of the following factors: parts, complexity of research, quality programs, hazards elimination, and single point failures elimination. The second project, for the Office of Safety and Facilities Assurance, required planning, layouts, and source seeking for an addition to the fire house. Forecasted changes in facility layout necessitate this addition which will serve as housing for the fire fighters.
Thompson, Keith A; Morrissey, Ryan P; Phan, Anita; Schwarz, Ernst R
2012-08-01
To determine the effects of the US economy on heart failure hospitalization rates. The recession was associated with worsening unemployment, loss of private insurance and prescription medication benefits, medication nonadherence, and ultimately increased rates of hospitalization for heart failure. We compared hospitalization rates at a large, single, academic medical center from July 1, 2006 to February 28, 2007, a time of economic stability, and July 1, 2008 to February 28, 2009, a time of economic recession in the United States. Significantly fewer patients had private medical insurance during the economic recession than during the control period (36.5% vs 46%; P = 0.04). Despite this, there were no differences in the heart failure hospitalization or readmission rates, length of hospitalization, need for admission to an intensive care unit, in-hospital mortality, or use of guideline-recommended heart failure medications between the 2 study periods. We conclude that despite significant effects on medical insurance coverage, rates of heart failure hospitalization at our institution were not significantly affected by the recession. Additional large-scale population-based research is needed to better understand the effects of fluctuations in the US economy on heart failure hospitalization rates. © 2012 Wiley Periodicals, Inc.
Management of heart failure in the new era: the role of scores.
Mantegazza, Valentina; Badagliacca, Roberto; Nodari, Savina; Parati, Gianfranco; Lombardi, Carolina; Di Somma, Salvatore; Carluccio, Erberto; Dini, Frank Lloyd; Correale, Michele; Magrì, Damiano; Agostoni, Piergiuseppe
2016-08-01
Heart failure is a widespread syndrome involving several organs, still characterized by high mortality and morbidity, and whose clinical course is heterogeneous and hardly predictable.In this scenario, the assessment of heart failure prognosis represents a fundamental step in clinical practice. A single parameter is always unable to provide a very precise prognosis. Therefore, risk scores based on multiple parameters have been introduced, but their clinical utility is still modest. In this review, we evaluated several prognostic models for acute, right, chronic, and end-stage heart failure based on multiple parameters. In particular, for chronic heart failure we considered risk scores essentially based on clinical evaluation, comorbidities analysis, baroreflex sensitivity, heart rate variability, sleep disorders, laboratory tests, echocardiographic imaging, and cardiopulmonary exercise test parameters. What is at present established is that a single parameter is not sufficient for an accurate prediction of prognosis in heart failure because of the complex nature of the disease. However, none of the scoring systems available is widely used, being in some cases complex, not user-friendly, or based on expensive or not easily available parameters. We believe that multiparametric scores for risk assessment in heart failure are promising but their widespread use needs to be experienced.
HIV-1 resistance dynamics in patients failing dolutegravir maintenance monotherapy.
Wijting, Ingeborg E A; Lungu, Cynthia; Rijnders, Bart J A; van der Ende, Marchina E; Pham, Hanh T; Mesplede, Thibault; Pas, Suzan D; Voermans, Jolanda J C; Schuurman, Rob; van de Vijver, David A M C; Boers, Patrick H M; Gruters, Rob A; Boucher, Charles A B; van Kampen, Jeroen J A
2018-03-29
A high genetic resistance barrier to the integrase-strand-transfer-inhibitor (INSTI) dolutegravir has been reported in vitro and in vivo. We describe the dynamics of INSTI-resistance-associated-mutations (INSTI-RAMs) and mutations in the 3'-polypurine tract (3'-PPT) in relation to virological failure (VF) observed in the randomized dolutegravir maintenance monotherapy study (DOMONO, NCT02401828). From ten patients with VF plasma samples prior to start cART and during VF were used to generate Sanger sequences of integrase, the 5' terminal bases of the 3'- LTR, and the 3'-PPT. Median HIV-RNA (IQR) at VF was 3,490 (1,440-4,990) c/mL. INSTI-RAMs were detected in 4/10 patients (S230R, R263K, N155H, E92Q+N155H) and in 4/10 patients no INSTI-RAMs were detected (2/10 patients integrase sequencing was unsuccessful). The time-to-VF ranged from 4 weeks to 72 weeks. In one patient, mutations developed in the highly conserved 3'-PPT. No changes in the terminal bases of the 3'-LTR were observed. The genetic barrier to resistance is too low to justify dolutegravir maintenance monotherapy as single INSTI-RAMs are sufficient to cause VF. The large variation in time-to-VF suggests that stochastic reactivation of a pre-existing provirus containing a single INSTI-RAM is the mechanism for failure. Changes in the 3'-PPT point to a new dolutegravir resistance mechanism in vivo.
How and why of orthodontic bond failures: An in vivo study
Vijayakumar, R. K.; Jagadeep, Raju; Ahamed, Fayyaz; Kanna, Aprose; Suresh, K.
2014-01-01
Introduction: The bonding of orthodontic brackets and their failure rates by both direct and in-direct procedures are well-documented in orthodontic literature. Over the years different adhesive materials and various indirect bonding transfer procedures have been compared and evaluated for bond failure rates. The aim of our study is to highlight the use of a simple, inexpensive and ease of manipulation of a single thermo-plastic transfer tray and the use the of a single light cure adhesive to evaluate the bond failure rates in clinical situations. Materials and Methods: A total of 30 patients were randomly divided into two groups (Group A and Group B). A split-mouth study design was used, for, both the groups so that they were distributed equally with-out bias. After initial prophylaxis, both the procedures were done as per manufactures instructions. All patients were initially motivated and reviewed for bond failures rates for 6 months. Results: Bond failure rates were assessed for over-all direct and indirect procedures, anterior and posterior arches, and for individual tooth. Z-test was used for statistically analyzing, the normal distribution of the sample in a spilt mouth study. The results of the two groups were compared and P value was calculated using Z-proportion test to assess the significance of the bond failure. Conclusion: Over-all bond failure was more for direct bonding. Anterior bracket failure was more in-direct bonding than indirect procedure, which showed more posterior bracket failures. In individual tooth bond failure, mandibular incisor, and premolar brackets showed more failure, followed by maxillary premolars and canines. PMID:25210392
Predicting Failure Progression and Failure Loads in Composite Open-Hole Tension Coupons
NASA Technical Reports Server (NTRS)
Arunkumar, Satyanarayana; Przekop, Adam
2010-01-01
Failure types and failure loads in carbon-epoxy [45n/90n/-45n/0n]ms laminate coupons with central circular holes subjected to tensile load are simulated using progressive failure analysis (PFA) methodology. The progressive failure methodology is implemented using VUMAT subroutine within the ABAQUS(TradeMark)/Explicit nonlinear finite element code. The degradation model adopted in the present PFA methodology uses an instantaneous complete stress reduction (COSTR) approach to simulate damage at a material point when failure occurs. In-plane modeling parameters such as element size and shape are held constant in the finite element models, irrespective of laminate thickness and hole size, to predict failure loads and failure progression. Comparison to published test data indicates that this methodology accurately simulates brittle, pull-out and delamination failure types. The sensitivity of the failure progression and the failure load to analytical loading rates and solvers precision is demonstrated.
A new yield and failure theory for composite materials under static and dynamic loading
Daniel, Isaac M.; Daniel, Sam M.; Fenner, Joel S.
2017-09-12
In order to facilitate and accelerate the process of introducing, evaluating and adopting new material systems, it is important to develop/establish comprehensive and effective procedures of characterization, modeling and failure prediction of composite structures based on the properties of the constituent materials, e. g., fibers, matrix, and the single ply or lamina. A new yield/failure theory is proposed for predicting lamina yielding and failure under multi-axial states of stress including strain rate effects. It is based on the equivalent stress concept derived from energy principles and is expressed in terms of a single criterion. It is presented in the formmore » of master yield and failure envelopes incorporating strain rate effects. The theory can be further adapted and extended to the prediction of in situ first ply yielding and failure (FPY and FPF) and progressive damage of multi-directional laminates under static and dynamic loadings. The significance of this theory is that it allows for rapid screening of new composite materials without extensive testing and offers easily implemented design tools.« less
A new yield and failure theory for composite materials under static and dynamic loading
DOE Office of Scientific and Technical Information (OSTI.GOV)
Daniel, Isaac M.; Daniel, Sam M.; Fenner, Joel S.
In order to facilitate and accelerate the process of introducing, evaluating and adopting new material systems, it is important to develop/establish comprehensive and effective procedures of characterization, modeling and failure prediction of composite structures based on the properties of the constituent materials, e. g., fibers, matrix, and the single ply or lamina. A new yield/failure theory is proposed for predicting lamina yielding and failure under multi-axial states of stress including strain rate effects. It is based on the equivalent stress concept derived from energy principles and is expressed in terms of a single criterion. It is presented in the formmore » of master yield and failure envelopes incorporating strain rate effects. The theory can be further adapted and extended to the prediction of in situ first ply yielding and failure (FPY and FPF) and progressive damage of multi-directional laminates under static and dynamic loadings. The significance of this theory is that it allows for rapid screening of new composite materials without extensive testing and offers easily implemented design tools.« less
NASA Technical Reports Server (NTRS)
Hammond, E. C., Jr.; Peters, K. A.; Gunther, S. O.; Cunningham, L. M.; Wright, D. D.
1985-01-01
Reciprocity failure was examined for IIaO spectroscopic film. The results indicate reciprocity failure occurs at three distinct minimum points in time; 15 min, 30 min and 90 min. The results are unique because theory suggests only one minimum reciprocity failure point should occur. When incubating 70mm IIaO film for 15 and 30 min at temperatures of 30, 40, 50, and 60 C and then placing in a liquid nitrogen bath at a temperature of -190 C the film demonstrated an increase of the optical density when developed at a warm-up time of 30 min. Longer warm-up periods of 1, 2 and 3 hrs yield a decrease in optical density of the darker wedge patterns; whereas, shorter warm-up times yield an overall increase in the optical densities.
Seismic precursory patterns before a cliff collapse and critical point phenomena
Amitrano, D.; Grasso, J.-R.; Senfaute, G.
2005-01-01
We analyse the statistical pattern of seismicity before a 1-2 103 m3 chalk cliff collapse on the Normandie ocean shore, Western France. We show that a power law acceleration of seismicity rate and energy in both 40 Hz-1.5 kHz and 2 Hz-10kHz frequency range, is defined on 3 orders of magnitude, within 2 hours from the collapse time. Simultaneously, the average size of the seismic events increases toward the time to failure. These in situ results are derived from the only station located within one rupture length distance from the rock fall rupture plane. They mimic the "critical point" like behavior recovered from physical and numerical experiments before brittle failures and tertiary creep failures. Our analysis of this first seismic monitoring data of a cliff collapse suggests that the thermodynamic phase transition models for failure may apply for cliff collapse. Copyright 2005 by the American Geophysical Union.
Donohue, David M; Santoni, Brandon G; Stoops, T Kyle; Tanner, Gregory; Diaz, Miguel A; Mighell, Mark
2018-06-01
To quantify the stability of 3 points of inferiorly directed versus 3 points of superiorly directed locking screw fixation compared with the full contingent of 6 points of locked screw fixation in the treatment of a 3-part proximal humerus fracture. A standardized 3-part fracture was created in 10 matched pairs (experimental groups) and 10 nonmatched humeri (control group). Osteosynthesis was performed using 3 locking screws in the superior hemisphere of the humeral head (suspension), 3 locking screws in the inferior hemisphere (buttress), or the full complement of 6 locking screws (control). Specimens were tested in varus cantilever bending (7.5 Nm) to 10,000 cycles or failure. Construct survival (%) and the cycles to failure were compared. Seven of 10 controls survived the 10,000-cycle runout (70%: 8193 average cycles to failure). No experimental constructs survived the 10,000-cycle runout. Suspension and buttress screw groups failed an average of 331 and 516 cycles, respectively (P = 1.00). The average number of cycles to failure and the number of humeri surviving the 10,000-cycle runout were greater in the control group than in the experimental groups (P ≤ 0.006). Data support the use of a full contingent of 6 points of locking screw fixation over 3 superior or 3 inferior points of fixation in the treatment of a 3-part proximal humerus fracture with a locking construct. No biomechanical advantage to the 3 buttress or 3 suspension screws used in isolation was observed.
Reliability analysis of single crystal NiAl turbine blades
NASA Technical Reports Server (NTRS)
Salem, Jonathan; Noebe, Ronald; Wheeler, Donald R.; Holland, Fred; Palko, Joseph; Duffy, Stephen; Wright, P. Kennard
1995-01-01
As part of a co-operative agreement with General Electric Aircraft Engines (GEAE), NASA LeRC is modifying and validating the Ceramic Analysis and Reliability Evaluation of Structures algorithm for use in design of components made of high strength NiAl based intermetallic materials. NiAl single crystal alloys are being actively investigated by GEAE as a replacement for Ni-based single crystal superalloys for use in high pressure turbine blades and vanes. The driving force for this research lies in the numerous property advantages offered by NiAl alloys over their superalloy counterparts. These include a reduction of density by as much as a third without significantly sacrificing strength, higher melting point, greater thermal conductivity, better oxidation resistance, and a better response to thermal barrier coatings. The current drawback to high strength NiAl single crystals is their limited ductility. Consequently, significant efforts including the work agreement with GEAE are underway to develop testing and design methodologies for these materials. The approach to validation and component analysis involves the following steps: determination of the statistical nature and source of fracture in a high strength, NiAl single crystal turbine blade material; measurement of the failure strength envelope of the material; coding of statistically based reliability models; verification of the code and model; and modeling of turbine blades and vanes for rig testing.
Kotooka, Norihiko; Kitakaze, Masafumi; Nagashima, Kengo; Asaka, Machiko; Kinugasa, Yoshiharu; Nochioka, Kotaro; Mizuno, Atsushi; Nagatomo, Daisuke; Mine, Daigo; Yamada, Yoko; Kuratomi, Akiko; Okada, Norihiro; Fujimatsu, Daisuke; Kuwahata, So; Toyoda, Shigeru; Hirotani, Shin-Ichi; Komori, Takahiro; Eguchi, Kazuo; Kario, Kazuomi; Inomata, Takayuki; Sugi, Kaoru; Yamamoto, Kazuhiro; Tsutsui, Hiroyuki; Masuyama, Tohru; Shimokawa, Hiroaki; Momomura, Shin-Ichi; Seino, Yoshihiko; Sato, Yasunori; Inoue, Teruo; Node, Koichi
2018-02-15
Home telemonitoring is becoming more important to home medical care for patients with heart failure. Since there are no data on home telemonitoring for Japanese patients with heart failure, we investigated its effect on cardiovascular outcomes. The HOMES-HF study was the first multicenter, open-label, randomized, controlled trial (RCT) to elucidate the effectiveness of home telemonitoring of physiological data, such as body weight, blood pressure, and pulse rate, for Japanese patients with heart failure (UMIN Clinical Trials Registry 000006839). The primary end-point was a composite of all-cause death or rehospitalization due to worsening heart failure. We analyzed 181 recently hospitalized patients with heart failure who were randomly assigned to a telemonitoring group (n = 90) or a usual care group (n = 91). The mean follow-up period was 15 (range 0-31) months. There was no statistically significant difference in the primary end-point between groups [hazard ratio (HR), 0.95; 95% confidence interval (CI), 0.548-1.648; p = 0.572]. Home telemonitoring for Japanese patients with heart failure was feasible; however, beneficial effects in addition to those of usual care were not demonstrated. Further investigation of more patients with severe heart failure, participation of home medical care providers, and use of a more integrated home telemonitoring system emphasizing communication as well as monitoring of symptoms and physiological data are required.
Wagner, Mathilde; Corcuera-Solano, Idoia; Lo, Grace; Esses, Steven; Liao, Joseph; Besa, Cecilia; Chen, Nelson; Abraham, Ginu; Fung, Maggie; Babb, James S; Ehman, Richard L; Taouli, Bachir
2017-08-01
Purpose To assess the determinants of technical failure of magnetic resonance (MR) elastography of the liver in a large single-center study. Materials and Methods This retrospective study was approved by the institutional review board. Seven hundred eighty-one MR elastography examinations performed in 691 consecutive patients (mean age, 58 years; male patients, 434 [62.8%]) in a single center between June 2013 and August 2014 were retrospectively evaluated. MR elastography was performed at 3.0 T (n = 443) or 1.5 T (n = 338) by using a gradient-recalled-echo pulse sequence. MR elastography and anatomic image analysis were performed by two observers. Additional observers measured liver T2* and fat fraction. Technical failure was defined as no pixel value with a confidence index higher than 95% and/or no apparent shear waves imaged. Logistic regression analysis was performed to assess potential predictive factors of technical failure of MR elastography. Results The technical failure rate of MR elastography at 1.5 T was 3.5% (12 of 338), while it was higher, 15.3% (68 of 443), at 3.0 T. On the basis of univariate analysis, body mass index, liver iron deposition, massive ascites, use of 3.0 T, presence of cirrhosis, and alcoholic liver disease were all significantly associated with failure of MR elastography (P < .004); but on the basis of multivariable analysis, only body mass index, liver iron deposition, massive ascites, and use of 3.0 T were significantly associated with failure of MR elastography (P < .004). Conclusion The technical failure rate of MR elastography with a gradient-recalled-echo pulse sequence was low at 1.5 T but substantially higher at 3.0 T. Massive ascites, iron deposition, and high body mass index were additional independent factors associated with failure of MR elastography of the liver with a two-dimensional gradient-recalled-echo pulse sequence. © RSNA, 2017.
Exenatide and the treatment of patients with Parkinson’s disease
Aviles-Olmos, Iciar; Dickson, John; Kefalopoulou, Zinovia; Djamshidian, Atbin; Ell, Peter; Soderlund, Therese; Whitton, Peter; Wyse, Richard; Isaacs, Tom; Lees, Andrew; Limousin, Patricia; Foltynie, Thomas
2013-01-01
Background. There is increasing interest in methods to more rapidly and cost-efficiently investigate drugs that are approved for clinical use in the treatment of another condition. Exenatide is a type 2 diabetes treatment that has been shown to have neuroprotective/neurorestorative properties in preclinical models of neurodegeneration. Methods. As a proof of concept, using a single-blind trial design, we evaluated the progress of 45 patients with moderate Parkinson’s disease (PD), randomly assigned to receive subcutaneous exenatide injection for 12 months or to act as controls. Their PD was compared after overnight withdrawal of conventional PD medication using blinded video assessment of the Movement Disorders Society Unified Parkinson’s Disease Rating Scale (MDS-UPDRS), together with several nonmotor tests, at baseline, 6 months, and 12 months and after a further 2-month washout period (14 months). Results. Exenatide was well tolerated, although weight loss was common and l-dopa dose failures occurred in a single patient. Single-blinded rating of the exenatide group suggested clinically relevant improvements in PD across motor and cognitive measures compared with the control group. Exenatide-treated patients had a mean improvement at 12 months on the MDS-UPDRS of 2.7 points, compared with mean decline of 2.2 points in control patients (P = 0.037). Conclusion. These results demonstrate a potential cost-efficient approach through which preliminary clinical data of possible biological effects are obtainable, prior to undertaking the major investment required for double-blind trials of a potential disease-modifying drug in PD. Trial registration. Clinicaltrials.gov NCT01174810. Funding. Cure Parkinson’s Trust. PMID:23728174
Failure analysis of single-bolted joint for lightweight composite laminates and metal plate
NASA Astrophysics Data System (ADS)
Li, Linjie; Qu, Junli; Liu, Xiangdong
2018-01-01
A three-dimensional progressive damage model was developed in ANSYS to predict the damage accumulation of single bolted joint in composite laminates under in-plane tensile loading. First, we describe the formulation and algorithm of this model. Second, we calculate the failure loads of the joint in fibre reinforced epoxy laminated composite plates and compare it with the experiment results, which validates that our model can appropriately simulate the ultimate tensile strength of the joints and the whole process of failure of structure. Finally, this model is applied to study the failure process of the light-weight composite material (USN125). The study also has a great potential to provide a strong basis for bolted joints design in composite Laminates as well as a simple tool for comparing different laminate geometries and bolt arrangements.
Compression failure mechanisms of single-ply, unidirectional, carbon-fiber composites
NASA Technical Reports Server (NTRS)
Ha, Jong-Bae; Nairn, John A.
1992-01-01
A single-ply composite compression test was used to study compression failure mechanisms as a function of fiber type, matrix type, and interfacial strength. Composites made with low- and intermediate-modulus fibers (Hercules AS4 and IM7) in either an epoxy (Hercules 3501-6) or a thermoplastic (ULTEM and LARC-TPI) matrix failed by kink banding and out-of-plane slip. The failures proceeded by rapid and catastrophic damage propagation across the specimen width. Composites made with high-modulus fibers (Hercules HMS4/3501-6) had a much lower compression strength. Their failures were characterized by kink banding and longitudinal splitting. The damage propagated slowly across the specimen width. Composites made with fibers treated to give low interfacial strength had low compression strength. These composites typically failed near the specimen ends and had long kink bands.
Improvement of Progressive Damage Model to Predicting Crashworthy Composite Corrugated Plate
NASA Astrophysics Data System (ADS)
Ren, Yiru; Jiang, Hongyong; Ji, Wenyuan; Zhang, Hanyu; Xiang, Jinwu; Yuan, Fuh-Gwo
2018-02-01
To predict the crashworthy composite corrugated plate, different single and stacked shell models are evaluated and compared, and a stacked shell progressive damage model combined with continuum damage mechanics is proposed and investigated. To simulate and predict the failure behavior, both of the intra- and inter- laminar failure behavior are considered. The tiebreak contact method, 1D spot weld element and cohesive element are adopted in stacked shell model, and a surface-based cohesive behavior is used to capture delamination in the proposed model. The impact load and failure behavior of purposed and conventional progressive damage models are demonstrated. Results show that the single shell could simulate the impact load curve without the delamination simulation ability. The general stacked shell model could simulate the interlaminar failure behavior. The improved stacked shell model with continuum damage mechanics and cohesive element not only agree well with the impact load, but also capture the fiber, matrix debonding, and interlaminar failure of composite structure.
Koifman, Edward; Grossman, Ehud; Elis, Avishay; Dicker, Dror; Koifman, Bella; Mosseri, Morris; Kuperstein, Rafael; Goldenberg, Ilan; Kamerman, Tamir; Levine-Tiefenbrun, Nava; Klempfner, Robert
2014-12-01
Heart failure with preserved ejection fraction (HFpEF) comprises a large portion of heart failure patients and portends poor prognosis with similar outcome to heart failure with reduced ejection fraction (HFrEF). Thus far, no medical therapy has been shown to improve clinical outcome in this common condition. The study is a randomized-controlled, multicenter clinical trial aimed to determine whether early posthospitalization comprehensive cardiac rehabilitation (CR) including exercise training (ET) in recently hospitalized HFpEF patients reduces the composite end point of all-cause mortality and hospitalizations in comparison with usual care (UC). After undergoing baseline evaluation, patients are randomized to either UC or to ambulatory comprehensive CR program. Patients in the CR arm will participate in a 6-month biweekly ET program according to a predefined protocol, in addition to a complementary home exercise prescribed by a specialist in CR. Exercise training will include endurance and low-intensity resistance training. Patients in the UC arm will be followed up at the outpatient clinic, with management according to current heart failure guidelines. Physician follow-up visits will be conducted at 3, 6, and 12 months for assessment of adherence to therapy and ET, functional status, quality of life, and clinical events. Secondary end points will include quality-of-life questionnaire, economic end points, blood pressure, and hemoglobin A1C levels. Cardiac rehabilitation and ET are relatively inexpensive and accessible and can be beneficial in HFpEF patients. Our trial is designed to evaluate the impact of early posthospitalization comprehensive rehabilitation program on clinical end points of mortality, hospitalization, and quality of life in HFpEF patients. Copyright © 2014 Elsevier Inc. All rights reserved.
Azithromycin versus Doxycycline for Urogenital Chlamydia trachomatis Infection.
Geisler, William M; Uniyal, Apurva; Lee, Jeannette Y; Lensing, Shelly Y; Johnson, Shacondra; Perry, Raymond C W; Kadrnka, Carmel M; Kerndt, Peter R
2015-12-24
Urogenital Chlamydia trachomatis infection remains prevalent and causes substantial reproductive morbidity. Recent studies have raised concern about the efficacy of azithromycin for the treatment of chlamydia infection. We conducted a randomized trial comparing oral azithromycin with doxycycline for the treatment of urogenital chlamydia infection among adolescents in youth correctional facilities, to evaluate the noninferiority of azithromycin (1 g in one dose) to doxycycline (100 mg twice daily for 7 days). The treatment was directly observed. The primary end point was treatment failure at 28 days after treatment initiation, with treatment failure determined on the basis of nucleic acid amplification testing, sexual history, and outer membrane protein A (OmpA) genotyping of C. trachomatis strains. Among the 567 participants enrolled, 284 were randomly assigned to receive azithromycin, and 283 were randomly assigned to receive doxycycline. A total of 155 participants in each treatment group (65% male) made up the per-protocol population. There were no treatment failures in the doxycycline group. In the azithromycin group, treatment failure occurred in 5 participants (3.2%; 95% confidence interval, 0.4 to 7.4%). The observed difference in failure rates between the treatment groups was 3.2 percentage points, with an upper boundary of the 90% confidence interval of 5.9 percentage points, which exceeded the prespecified absolute 5-percentage-point cutoff for establishing the noninferiority of azithromycin. In the context of a closed population receiving directly observed treatment for urogenital chlamydia infection, the efficacy of azithromycin was 97%, and the efficacy of doxycycline was 100%. The noninferiority of azithromycin was not established in this setting. (Funded by the National Institute of Allergy and Infectious Diseases; ClinicalTrials.gov number, NCT00980148.).
2017-06-30
along the intermetallic component or at the interface between the two components of the composite. The availability of rnicroscale experimental data in...obtained with the PD model; (c) map of strain energy density; (d) the new quasi -index damage is a predictor of fai lure. As in the case of FRCs, one...which points are most likely to fail, before actual failure happens. The " quasi -damage index", shown in the formula below, is a point-wise measure
Dysregulated microRNA Activity in Shwachman-Diamond Syndrome
2016-09-01
define transcriptional signatures of bone marrow failure in SDS using single cell RNA -seq of patient cells. We will analyze these datasets to test the...microRNA expression profiles from HSPCs to be overlaid onto mRNA profiles. 15. SUBJECT TERMS Single cell RNA -seq; bone marrow failure; hematopoiesis...myelopoiesis; targeted RNA -seq 16. SECURITY CLASSIFICATION OF: U 17. LIMITATION OF ABSTRACT 18. NUMBER OF PAGES 19a. NAME OF RESPONSIBLE PERSON
Management of Severe Pancreatic Fistula After Pancreatoduodenectomy.
Smits, F Jasmijn; van Santvoort, Hjalmar C; Besselink, Marc G; Batenburg, Marilot C T; Slooff, Robbert A E; Boerma, Djamila; Busch, Olivier R; Coene, Peter P L O; van Dam, Ronald M; van Dijk, David P J; van Eijck, Casper H J; Festen, Sebastiaan; van der Harst, Erwin; de Hingh, Ignace H J T; de Jong, Koert P; Tol, Johanna A M G; Borel Rinkes, Inne H M; Molenaar, I Quintus
2017-06-01
Postoperative pancreatic fistula is a potentially life-threatening complication after pancreatoduodenectomy. Evidence for best management is lacking. To evaluate the clinical outcome of patients undergoing catheter drainage compared with relaparotomy as primary treatment for pancreatic fistula after pancreatoduodenectomy. A multicenter, retrospective, propensity-matched cohort study was conducted in 9 centers of the Dutch Pancreatic Cancer Group from January 1, 2005, to September 30, 2013. From a cohort of 2196 consecutive patients who underwent pancreatoduodenectomy, 309 patients with severe pancreatic fistula were included. Propensity score matching (based on sex, age, comorbidity, disease severity, and previous reinterventions) was used to minimize selection bias. Data analysis was performed from January to July 2016. First intervention for pancreatic fistula: catheter drainage or relaparotomy. Primary end point was in-hospital mortality; secondary end points included new-onset organ failure. Of the 309 patients included in the analysis, 209 (67.6%) were men, and mean (SD) age was 64.6 (10.1) years. Overall in-hospital mortality was 17.8% (55 patients): 227 patients (73.5%) underwent primary catheter drainage and 82 patients (26.5%) underwent primary relaparotomy. Primary catheter drainage was successful (ie, survival without relaparotomy) in 175 patients (77.1%). With propensity score matching, 64 patients undergoing primary relaparotomy were matched to 64 patients undergoing primary catheter drainage. Mortality was lower after catheter drainage (14.1% vs 35.9%; P = .007; risk ratio, 0.39; 95% CI, 0.20-0.76). The rate of new-onset single-organ failure (4.7% vs 20.3%; P = .007; risk ratio, 0.15; 95% CI, 0.03-0.60) and new-onset multiple-organ failure (15.6% vs 39.1%; P = .008; risk ratio, 0.40; 95% CI, 0.20-0.77) were also lower after primary catheter drainage. In this propensity-matched cohort, catheter drainage as first intervention for severe pancreatic fistula after pancreatoduodenectomy was associated with a better clinical outcome, including lower mortality, compared with primary relaparotomy.
Acute Decompensated Heart Failure: New Strategies for Improving Outcomes.
Singer Fisher, Emily; Burns, Boyd
2017-05-01
Acute decompensated heart failure is a common emergency department presentation with significant associated morbidity and mortality. Heart failure accounts for more than 1 million hospitalizations annually, with a steadily increasing incidence as our population ages. This issue reviews recent literature regarding appropriate management of emergency department presentations of acute decompensated heart failure, with special attention to newer medication options. Emergency department management and appropriate interventions are discussed, along with critical decision-making points in resuscitation for both hypertensive and hypotensive patients.
Effect of Crystal Orientation on Analysis of Single-Crystal, Nickel-Based Turbine Blade Superalloys
NASA Technical Reports Server (NTRS)
Swanson, G. R.; Arakere, N. K.
2000-01-01
High-cycle fatigue-induced failures in turbine and turbopump blades is a pervasive problem. Single-crystal nickel turbine blades are used because of their superior creep, stress rupture, melt resistance, and thermomechanical fatigue capabilities. Single-crystal materials have highly orthotropic properties making the position of the crystal lattice relative to the part geometry a significant and complicating factor. A fatigue failure criterion based on the maximum shear stress amplitude on the 24 octahedral and 6 cube slip systems is presented for single-crystal nickel superalloys (FCC crystal). This criterion greatly reduces the scatter in uniaxial fatigue data for PWA 1493 at 1,200 F in air. Additionally, single-crystal turbine blades used in the Space Shuttle main engine high pressure fuel turbopump/alternate turbopump are modeled using a three-dimensional finite element (FE) model. This model accounts for material orthotrophy and crystal orientation. Fatigue life of the blade tip is computed using FE stress results and the failure criterion that was developed. Stress analysis results in the blade attachment region are also presented. Results demonstrate that control of crystallographic orientation has the potential to significantly increase a component's resistance to fatigue crack growth without adding additional weight or cost.
Sharma, Rajinder P; Ree, Chung Ja; Ree, Alexander
2008-01-01
To evaluate the effectiveness and safety of a single 2 mg dose or a 4 mg double dose of alteplase for restoring function in occluded chest ports. A prospective, open-label, nonblinded study was performed on 40 enrolled patients with a total of 50 chest ports at the Henry Ford Hospital Interventional Radiology Department (Detroid, Michigan, USA). Alteplase (Cathflo Activase; Genentech, USA), a recombinant tissue plasminogen activator produced by recombinant DNA technology, was used to restore the function of 50 occluded chest ports. Occlusion was defined as the inability to withdraw blood freely from the port, or the inability to flush the port easily. A 2 mg (2 mL) dose of alteplase was injected into the port through a Huber needle, using a gentle push and pull technique, and was left to dwell for 30 min. If the port remained occluded after the initial 2 mg alteplase treatment, an additional 2 mg alteplase treatment was administered with the same dwell time of 30 min. If a port had remained occluded despite the above regimen, this outcome would have been considered a failure and the chest port would have required surgical intervention. However, all ports were successfully treated, and no surgical intervention was required. The safety end points included minor or major hemorrhages, such as intracranial hemorrhages, or sepsis. Safety end points were determined by a 24 h follow-up telephone call. Of the 50 chest ports (30 single ports and 10 double ports) treated with alteplase, 36 required 2 mg (72%) and 14 required 4 mg (28%). The efficacy end point was 100% for all chest ports treated, without any adverse events. High efficacy and safety rates of restoring function in occluded chest ports were obtained with 2 mg or 4 mg doses of alteplase. Part of this high efficacy rate may be due to the gentle push and pull technique used in the present study.
A Novel Multiscale Physics Based Progressive Failure Methodology for Laminated Composite Structures
NASA Technical Reports Server (NTRS)
Pineda, Evan J.; Waas, Anthony M.; Bednarcyk, Brett A.; Collier, Craig S.; Yarrington, Phillip W.
2008-01-01
A variable fidelity, multiscale, physics based finite element procedure for predicting progressive damage and failure of laminated continuous fiber reinforced composites is introduced. At every integration point in a finite element model, progressive damage is accounted for at the lamina-level using thermodynamically based Schapery Theory. Separate failure criteria are applied at either the global-scale or the microscale in two different FEM models. A micromechanics model, the Generalized Method of Cells, is used to evaluate failure criteria at the micro-level. The stress-strain behavior and observed failure mechanisms are compared with experimental results for both models.
Time-dependent earthquake probabilities
Gomberg, J.; Belardinelli, M.E.; Cocco, M.; Reasenberg, P.
2005-01-01
We have attempted to provide a careful examination of a class of approaches for estimating the conditional probability of failure of a single large earthquake, particularly approaches that account for static stress perturbations to tectonic loading as in the approaches of Stein et al. (1997) and Hardebeck (2004). We have loading as in the framework based on a simple, generalized rate change formulation and applied it to these two approaches to show how they relate to one another. We also have attempted to show the connection between models of seismicity rate changes applied to (1) populations of independent faults as in background and aftershock seismicity and (2) changes in estimates of the conditional probability of failures of different members of a the notion of failure rate corresponds to successive failures of different members of a population of faults. The latter application requires specification of some probability distribution (density function of PDF) that describes some population of potential recurrence times. This PDF may reflect our imperfect knowledge of when past earthquakes have occurred on a fault (epistemic uncertainty), the true natural variability in failure times, or some combination of both. We suggest two end-member conceptual single-fault models that may explain natural variability in recurrence times and suggest how they might be distinguished observationally. When viewed deterministically, these single-fault patch models differ significantly in their physical attributes, and when faults are immature, they differ in their responses to stress perturbations. Estimates of conditional failure probabilities effectively integrate over a range of possible deterministic fault models, usually with ranges that correspond to mature faults. Thus conditional failure probability estimates usually should not differ significantly for these models. Copyright 2005 by the American Geophysical Union.
Tucker, Bram; Tsiazonera; Tombo, Jaovola; Hajasoa, Patricia; Nagnisaha, Charlotte
2015-01-01
A fact of life for farmers, hunter-gatherers, and fishermen in the rural parts of the world are that crops fail, wild resources become scarce, and winds discourage fishing. In this article we approach subsistence risk from the perspective of “coexistence thinking,” the simultaneous application of natural and supernatural causal models to explain subsistence success and failure. In southwestern Madagascar, the ecological world is characterized by extreme variability and unpredictability, and the cosmological world is characterized by anxiety about supernatural dangers. Ecological and cosmological causes seem to point to different risk minimizing strategies: to avoid losses from drought, flood, or heavy winds, one should diversify activities and be flexible; but to avoid losses caused by disrespected spirits one should narrow one’s range of behaviors to follow the code of taboos and offerings. We address this paradox by investigating whether southwestern Malagasy understand natural and supernatural causes as occupying separate, contradictory explanatory systems (target dependence), whether they make no categorical distinction between natural and supernatural forces and combine them within a single explanatory system (synthetic thinking), or whether they have separate natural and supernatural categories of causes that are integrated into one explanatory system so that supernatural forces drive natural forces (integrative thinking). Results from three field studies suggest that (a) informants explain why crops, prey, and market activities succeed or fail with reference to natural causal forces like rainfall and pests, (b) they explain why individual persons experience success or failure primarily with supernatural factors like God and ancestors, and (c) they understand supernatural forces as driving natural forces, so that ecology and cosmology represent distinct sets of causes within a single explanatory framework. We expect that future cross-cultural analyses may find that this form of “integrative thinking” is common in unpredictable environments and is a cognitive strategy that accompanies economic diversification. PMID:26528205
Tucker, Bram; Tsiazonera; Tombo, Jaovola; Hajasoa, Patricia; Nagnisaha, Charlotte
2015-01-01
A fact of life for farmers, hunter-gatherers, and fishermen in the rural parts of the world are that crops fail, wild resources become scarce, and winds discourage fishing. In this article we approach subsistence risk from the perspective of "coexistence thinking," the simultaneous application of natural and supernatural causal models to explain subsistence success and failure. In southwestern Madagascar, the ecological world is characterized by extreme variability and unpredictability, and the cosmological world is characterized by anxiety about supernatural dangers. Ecological and cosmological causes seem to point to different risk minimizing strategies: to avoid losses from drought, flood, or heavy winds, one should diversify activities and be flexible; but to avoid losses caused by disrespected spirits one should narrow one's range of behaviors to follow the code of taboos and offerings. We address this paradox by investigating whether southwestern Malagasy understand natural and supernatural causes as occupying separate, contradictory explanatory systems (target dependence), whether they make no categorical distinction between natural and supernatural forces and combine them within a single explanatory system (synthetic thinking), or whether they have separate natural and supernatural categories of causes that are integrated into one explanatory system so that supernatural forces drive natural forces (integrative thinking). Results from three field studies suggest that (a) informants explain why crops, prey, and market activities succeed or fail with reference to natural causal forces like rainfall and pests, (b) they explain why individual persons experience success or failure primarily with supernatural factors like God and ancestors, and (c) they understand supernatural forces as driving natural forces, so that ecology and cosmology represent distinct sets of causes within a single explanatory framework. We expect that future cross-cultural analyses may find that this form of "integrative thinking" is common in unpredictable environments and is a cognitive strategy that accompanies economic diversification.
Microseismic Signature of Magma Failure: Testing Failure Forecast in Heterogeneous Material
NASA Astrophysics Data System (ADS)
Vasseur, J.; Lavallee, Y.; Hess, K.; Wassermann, J. M.; Dingwell, D. B.
2012-12-01
Volcanoes exhibit a range of seismic precursors prior to eruptions. This range of signals derive from different processes, which if quantified, may tell us when and how the volcano will erupt: effusively or explosively. This quantification can be performed in laboratory. Here we investigated the signals associated with the deformation and failure of single-phase silicate liquids compare to mutli-phase magmas containing pores and crystals as heterogeneities. For the past decades, magmas have been simplified as viscoelastic fluids with grossly predictable failure, following an analysis of the stress and strain rate conditions in volcanic conduits. Yet it is clear that the way magmas fail is not unique and evidences increasingly illustrate the role of heterogeneities in the process of magmatic fragmentation. In such multi-phase magmas, failure cannot be predicted using current rheological laws. Microseismicity, as detected in the laboratory by analogous Acoustic Emission (AE), can be used to monitor fracture initiation and propagation, and thus provides invaluable information to characterise the process of brittle failure underlying explosive eruptions. Tri-axial press experiments on different synthetised and natural glass samples have been performed to investigate the acoustic signature of failure. We observed that the failure of single-phase liquids occurs without much strain and is preceded by the constant nucleation, propagation and coalescence of cracks as demonstrated by the monitored AE. In contrast, the failure of multi-phase magmas depends on the applied stress and is strain dependent. The path dependence of magma failure is nonetheless accompanied by supra exponential acceleration in released AEs. Analysis of the released AEs following material Failure Forecast Method (FFM) suggests that the predicability of failure is enhanced by the presence of heterogeneities in magmas. We discuss our observations in terms of volcanic scenarios.
What Reliability Engineers Should Know about Space Radiation Effects
NASA Technical Reports Server (NTRS)
DiBari, Rebecca
2013-01-01
Space radiation in space systems present unique failure modes and considerations for reliability engineers. Radiation effects is not a one size fits all field. Threat conditions that must be addressed for a given mission depend on the mission orbital profile, the technologies of parts used in critical functions and on application considerations, such as supply voltages, temperature, duty cycle, and redundancy. In general, the threats that must be addressed are of two types-the cumulative degradation mechanisms of total ionizing dose (TID) and displacement damage (DD). and the prompt responses of components to ionizing particles (protons and heavy ions) falling under the heading of single-event effects. Generally degradation mechanisms behave like wear-out mechanisms on any active components in a system: Total Ionizing Dose (TID) and Displacement Damage: (1) TID affects all active devices over time. Devices can fail either because of parametric shifts that prevent the device from fulfilling its application or due to device failures where the device stops functioning altogether. Since this failure mode varies from part to part and lot to lot, lot qualification testing with sufficient statistics is vital. Displacement damage failures are caused by the displacement of semiconductor atoms from their lattice positions. As with TID, failures can be either parametric or catastrophic, although parametric degradation is more common for displacement damage. Lot testing is critical not just to assure proper device fi.mctionality throughout the mission. It can also suggest remediation strategies when a device fails. This paper will look at these effects on a variety of devices in a variety of applications. This paper will look at these effects on a variety of devices in a variety of applications. (2) On the NEAR mission a functional failure was traced to a PIN diode failure caused by TID induced high leakage currents. NEAR was able to recover from the failure by reversing the current of a nearby Thermal Electric Cooler (turning the TEC into a heater). The elevated temperature caused the PIN diode to anneal and the device to recover. It was by lot qualification testing that NEAR knew the diode would recover when annealed. This paper will look at these effects on a variety of devices in a variety of applications. Single Event Effects (SEE): (1) In contrast to TID and displacement damage, Single Event Effects (SEE) resemble random failures. SEE modes can range from changes in device logic (single-event upset, or SEU). temporary disturbances (single-event transient) to catastrophic effects such as the destructive SEE modes, single-event latchup (SEL). single-event gate rupture (SEGR) and single-event burnout (SEB) (2) The consequences of nondestructive SEE modes such as SEU and SET depend critically on their application--and may range from trivial nuisance errors to catastrophic loss of mission. It is critical not just to ensure that potentially susceptible devices are well characterized for their susceptibility, but also to work with design engineers to understand the implications of each error mode. -For destructive SEE, the predominant risk mitigation strategy is to avoid susceptible parts, or if that is not possible. to avoid conditions under which the part may be susceptible. Destructive SEE mechanisms are often not well understood, and testing is slow and expensive, making rate prediction very challenging. (3) Because the consequences of radiation failure and degradation modes depend so critically on the application as well as the component technology, it is essential that radiation, component. design and system engineers work togetherpreferably starting early in the program to ensure critical applications are addressed in time to optimize the probability of mission success.
Failure prediction of thin beryllium sheets used in spacecraft structures
NASA Technical Reports Server (NTRS)
Roschke, Paul N.; Mascorro, Edward; Papados, Photios; Serna, Oscar R.
1991-01-01
The primary objective of this study is to develop a method for prediction of failure of thin beryllium sheets that undergo complex states of stress. Major components of the research include experimental evaluation of strength parameters for cross-rolled beryllium sheet, application of the Tsai-Wu failure criterion to plate bending problems, development of a high order failure criterion, application of the new criterion to a variety of structures, and incorporation of both failure criteria into a finite element code. A Tsai-Wu failure model for SR-200 sheet material is developed from available tensile data, experiments carried out by NASA on two circular plates, and compression and off-axis experiments performed in this study. The failure surface obtained from the resulting criterion forms an ellipsoid. By supplementing experimental data used in the the two-dimensional criterion and modifying previously suggested failure criteria, a multi-dimensional failure surface is proposed for thin beryllium structures. The new criterion for orthotropic material is represented by a failure surface in six-dimensional stress space. In order to determine coefficients of the governing equation, a number of uniaxial, biaxial, and triaxial experiments are required. Details of these experiments and a complementary ultrasonic investigation are described in detail. Finally, validity of the criterion and newly determined mechanical properties is established through experiments on structures composed of SR200 sheet material. These experiments include a plate-plug arrangement under a complex state of stress and a series of plates with an out-of-plane central point load. Both criteria have been incorporated into a general purpose finite element analysis code. Numerical simulation incrementally applied loads to a structural component that is being designed and checks each nodal point in the model for exceedance of a failure criterion. If stresses at all locations do not exceed the failure criterion, the load is increased and the process is repeated. Failure results for the plate-plug and clamped plate tests are accurate to within 2 percent.
Factors Affecting Health Related Quality of Life in Hospitalized Patients with Heart Failure.
Audi, Georgia; Korologou, Aggeliki; Koutelekos, Ioannis; Vasilopoulos, Georgios; Karakostas, Kostas; Makrygianaki, Kleanthi; Polikandrioti, Maria
2017-01-01
This study identified factors affecting health related quality of life (HRQOL) in 300 hospitalized patients with heart failure (HF). Data were collected by the completion of a questionnaire which included patients' characteristics and the Minnesota Living with Heart Failure Questionnaire (MLHFQ). Analysis of data showed that the median of the total score of MLHFQ was 46 and the median of the physical and mental state was 22 and 6, respectively. Also, participants who were householders or had "other" professions had lower score of 17 points and therefore better quality of life compared to patients who were civil/private employees ( p < 0.001 and p < 0.001, resp.). Patients not receiving anxiolytics and antidepressants had lower quality of life scores of 6 and 15.5 points, respectively, compared to patients who received ( p = 0.003 and p < 0.001, resp.). Patients with no prior hospitalization had lower score of 7 points compared to those with prior hospitalization ( p = 0.002), whereas patients not retired due to the disease had higher score of 7 points ( p = 0.034). Similar results were observed for the physical and mental state. Improvement of HF patients' quality of life should come to the forefront of clinical practice.
A Bayesian Framework for Human Body Pose Tracking from Depth Image Sequences
Zhu, Youding; Fujimura, Kikuo
2010-01-01
This paper addresses the problem of accurate and robust tracking of 3D human body pose from depth image sequences. Recovering the large number of degrees of freedom in human body movements from a depth image sequence is challenging due to the need to resolve the depth ambiguity caused by self-occlusions and the difficulty to recover from tracking failure. Human body poses could be estimated through model fitting using dense correspondences between depth data and an articulated human model (local optimization method). Although it usually achieves a high accuracy due to dense correspondences, it may fail to recover from tracking failure. Alternately, human pose may be reconstructed by detecting and tracking human body anatomical landmarks (key-points) based on low-level depth image analysis. While this method (key-point based method) is robust and recovers from tracking failure, its pose estimation accuracy depends solely on image-based localization accuracy of key-points. To address these limitations, we present a flexible Bayesian framework for integrating pose estimation results obtained by methods based on key-points and local optimization. Experimental results are shown and performance comparison is presented to demonstrate the effectiveness of the proposed approach. PMID:22399933
NASA Technical Reports Server (NTRS)
Brichenough, A. G.
1975-01-01
The control system consists of the ac-dc conversion, voltage regulation, speed regulation through parasitic load control, and overload control. A no-single-failure configuration was developed to attain the required reliability for a 10-year design life of unattended operation. The design principles, complete schematics, and performance are reported. Testing was performed on an alternator simulator pending construction of the actual Mini-Brayton alternator.
The single-payer option: a reconsideration.
Oliver, Adam
2009-08-01
This article discusses some of the merits and demerits of the single-payer model of health care financing, with particular reference to the English National Health Service (NHS). Specifically, it is argued that the main merits are that the model can directly provide universal health care coverage, thus eradicating or at least alleviating market failure and equity concerns, and that it can achieve this with relatively low total health care expenditure in general and -- as compared to the commercial multiple insurance model -- low administrative costs in particular. A perceived demerit of the single-payer model is that it can lead to excessive health care rationing, particularly in terms of waiting times, although it is argued here that long waits are probably caused by insufficient funding rather than by the single-payer model per se. Moreover, rationing of one form or another occurs in all health care systems, and single-payer models may be the best option if the aim is to incorporate structured rationing such that an entire population is subject to the same rules and is thus treated equitably. A further perceived disadvantage of the single-payer model is that it offers limited choice, which is necessarily true with respect to choice of insurer, but choice of provider can be, and increasingly is, a feature of centrally tax-financed health care systems. No model of health care funding is perfect; trade-offs are inevitable. Whether the merits of the single-payer model are judged to outweigh the demerits will typically vary both across countries at any point in time and within a country over time.
Fluid removal in acute heart failure: diuretics versus devices.
Krishnamoorthy, Arun; Felker, G Michael
2014-10-01
Fluid removal and relief of congestion are central to treatment of acute heart failure. Diuretics have been the decongestive mainstay but their known limitations have led to the exploration of alternative strategies. This review compares diuretics with ultrafiltration and examines the recent evidence evaluating their use. Relevant recent studies are the Diuretic Optimization Strategies Evaluation trial (of diuretics) and the Cardiorenal Rescue Study in Acute Decompensated Heart Failure (of ultrafiltration). The Diuretic Optimization Strategies Evaluation study evaluated strategies of loop diuretic use during acute heart failure (continuous infusion versus intermittent bolus and high dose versus low dose). After 72 h, there was no significant difference with either comparison for the coprimary end points. Patients treated with a high-dose strategy tended to have greater diuresis and more decongestion compared with low-dose therapy, at the cost of transient changes in renal function. The Cardiorenal Rescue Study in Acute Decompensated Heart Failure study showed that in acute heart failure patients with persistent congestion and worsening renal function, ultrafiltration, as compared with a medical therapy, was associated with similar weight loss but greater increase in serum creatinine and more adverse events. Decongestion remains a major challenge in acute heart failure. Although recent studies provide useful data to guide practice, the relatively poor outcomes point to the continued need to identify better strategies for safe and effective decongestion.
Multimaterial lamination as a means of retarding penetration and spallation failures in plates
NASA Technical Reports Server (NTRS)
Dibattista, J. D.; Humes, D. H.
1972-01-01
Experimental data are presented which show that hypervelocity impact spallation and penetration failures of a single solid aluminum plate and of a solid aluminum plate spaced a distance behind a Whipple meteor bumper may be retarded by replacing the solid aluminum plate with a laminated plate. Four sets of experiments were conducted. The first set of experiments was conducted with projectile mass and velocity held constant and with polycarbonate cylinders impacted into single plates of different construction. The second set of experiments was done with single plates of various construction and aluminum spherical projectiles of similar mass but different velocities. These two experiments showed that a laminated plate of aluminum and polycarbonate or aluminum and methyl methacrylate could prevent spallation and penetration failures with a lower areal density than either an all-aluminum laminated plate or a solid aluminum plate. The aluminum laminated plate was in turn superior to the solid aluminum plate in resisting spallation and penetration failures. In addition, through an example of 6061-T6 aluminum and methyl methacrylate, it is shown that a laminated structure ballistically superior to its parent materials may be built. The last two sets of experiments were conducted using bumper-protected main walls of solid aluminum and of laminated aluminum and polycarbonate. Again, under hypervelocity impact conditions, the laminated main walls were superior to the solid aluminum main walls in retarding spallation and penetration failures.
Resistivity tomography of Pointe du Hoc cliffs for stability assessment
NASA Astrophysics Data System (ADS)
Udphuay, S.; Everett, M. E.; Warden, R.
2008-12-01
Pointe du Hoc WWII battlefield overlooking the English Channel in western Normandy, France, is an important cultural resource, being an integral component of the June 6 1944 D-Day invasion. Two major buildings, the forward observation post (OP) and Col. Rudder's command post (RCP), are now perched perilously close to the cliff's edge owing to six decades of cliff retreat. Geophysical surveys were carried out in March 2008 to investigate the risk of cliff failure and to inform possible geotechnical remediation strategies with a final goal toward re-opening the observation post that is now closed to visitors. The geophysical surveying is accomplished by high-resolution resistivity tomography, conducted in extreme topography and in the midst of dense cultural clutter. The results of the OP tomography indicate that the highest mass movement hazard is associated with the marine caverns at the base of the cliff at the point of strongest wave attack. These caverns occupy the future site of a sea arch which will threaten the OP building. There is a high probability of a soil wedge failure on the east facing cliff edge close to the OP building. Such a failure could damage or destroy the building. The possibility of a sudden catastrophic failure along any one of these fractures cannot be ruled out. The greatest risk at the RCP site, which is under less immediate threat, is associated with soil wedge failures at the top of the cliffs.
An investigation of gear mesh failure prediction techniques. M.S. Thesis - Cleveland State Univ.
NASA Technical Reports Server (NTRS)
Zakrajsek, James J.
1989-01-01
A study was performed in which several gear failure prediction methods were investigated and applied to experimental data from a gear fatigue test apparatus. The primary objective was to provide a baseline understanding of the prediction methods and to evaluate their diagnostic capabilities. The methods investigated use the signal average in both the time and frequency domain to detect gear failure. Data from eleven gear fatigue tests were recorded at periodic time intervals as the gears were run from initiation to failure. Four major failure modes, consisting of heavy wear, tooth breakage, single pits, and distributed pitting were observed among the failed gears. Results show that the prediction methods were able to detect only those gear failures which involved heavy wear or distributed pitting. None of the methods could predict fatigue cracks, which resulted in tooth breakage, or single pits. It is suspected that the fatigue cracks were not detected because of limitations in data acquisition rather than in methodology. Additionally, the frequency response between the gear shaft and the transducer was found to significantly affect the vibration signal. The specific frequencies affected were filtered out of the signal average prior to application of the methods.
Han, Ahram; Min, Seung-Kee; Kim, Mi-Sook; Joo, Kwon Wook; Kim, Jungsun; Ha, Jongwon; Lee, Joongyub; Min, Sang-Il
2016-10-07
Use of arteriovenous fistulas, the most preferred type of access for hemodialysis, is limited by their high maturation failure rate. The aim of this study was to assess whether aggressive surveillance with routine duplex ultrasound and intervention can decrease the maturation failure rate of arteriovenous fistulas. We conducted a single-center, parallel-group, randomized, controlled trial of patients undergoing autogenous arteriovenous fistula. Patients were randomly assigned (1:1) to either the routine duplex or selective duplex group. In the routine duplex group, duplex ultrasound and physical examination were performed 2, 4, and 8 weeks postoperatively. In the selective duplex group, duplex examination was performed only when physical examination detected an abnormality. The primary end point was the maturation failure rate 8 weeks after fistula creation. Maturation failure was defined as the inability to achieve clinical maturation ( i.e. , a successful first use) and failure to achieve sonographic maturation (fistula flow >500 ml/min and diameter >6 mm) within 8 weeks. Between June 14, 2012, and June 25, 2014, 150 patients were enrolled (75 patients in each group), and 118 of those were included in the final analysis. The maturation failure rate was lower in the routine duplex group (8 of 59; 13.6%) than in the selective duplex group (15 of 59; 25.4%), but the difference was not statistically significant (odds ratio, 0.46; 95% confidence interval, 0.18 to 1.19; P =0.10). Factors associated with maturation failure were women (odds ratio, 3.84; 95% confidence interval, 1.05 to 14.06; P =0.04), coronary artery disease (odds ratio, 6.36; 95% confidence interval, 1.62 to 24.95; P <0.01), diabetes (odds ratio, 6.10; 95% confidence interval, 1.76 to 21.19; P <0.01), and the preoperative cephalic vein diameter (odds ratio, 0.30; 95% confidence interval, 0.13 to 0.71; P <0.01). Postoperative routine duplex surveillance failed to prove superiority compared with selective duplex after physical examination for reducing arteriovenous fistula maturation failure. However, the wide 95% confidence interval for the effect of intervention precludes a firm conclusion that routine duplex surveillance was not beneficial. Copyright © 2016 by the American Society of Nephrology.
Lowenthal, Elizabeth D.; Ellenberg, Jonas H.; Machine, Edwin; Sagdeo, Aditi; Boiditswe, Sefelani; Steenhoff, Andrew P.; Rutstein, Richard; Anabwani, Gabriel; Gross, Robert
2013-01-01
Importance Worldwide, the nonnucleoside reverse transcriptase inhibitors (NNRTIs) efavirenz and nevirapine are commonly used in first-line antiretroviral regimens in both adults and children with human immunodeficiency virus (HIV) infection. Data on the comparative effectiveness of these medications in children are limited. Objective To investigate whether virological failure is more likely among children who initiated 1 or the other NNRTI-based HIV treatment. Design, Setting, and Participants Retrospective cohort study of children (aged 3–16 years) who initiated efavirenz-based (n=421) or nevirapine-based (n=383) treatment between April 2002 and January 2011 at a large pediatric HIV care setting in Botswana. Main Outcomes and Measures The primary outcome was time from initiation of therapy to virological failure. Virological failure was defined as lack of plasma HIV RNA suppression to less than 400 copies/mL by 6 months or confirmed HIV RNA of 400 copies/mL or greater after suppression. Cox proportional hazards regression analysis compared time to virological failure by regimen. Multivariable Cox regression controlled for age, sex, baseline immunologic category, baseline clinical category, baseline viral load, nutritional status, NRTIs used, receipt of single-dose nevirapine, and treatment for tuberculosis. Results With a median follow-up time of 69 months (range, 6–112 months; interquartile range, 23–87 months), 57 children (13.5%; 95% CI, 10.4%–17.2%) initiating treatment with efavirenz and 101 children (26.4%; 95% CI, 22.0%–31.1%) initiating treatment with nevirapine had virological failure. There were 11 children (2.6%; 95% CI, 1.3%–4.6%) receiving efavirenz and 20 children (5.2%; 95% CI, 3.2%–7.9%) receiving nevirapine who never achieved virological suppression. The Cox proportional hazard ratio for the combined virological failure end point was 2.0 (95% CI, 1.4–2.7; log rank P<.001, favoring efavirenz). None of the measured covariates affected the estimated hazard ratio in the multivariable analyses. Conclusions and Relevance Among children aged 3 to 16 years infected with HIV and treated at a clinic in Botswana, the use of efavirenz compared with nevirapine as initial antiretroviral treatment was associated with less virological failure. These findings may warrant additional research evaluating the use of efavirenz and nevirapine for pediatric patients. PMID:23632724
Albumin Dialysis for Liver Failure: A Systematic Review.
Tsipotis, Evangelos; Shuja, Asim; Jaber, Bertrand L
2015-09-01
Albumin dialysis is the best-studied extracorporeal nonbiologic liver support system as a bridge or destination therapy for patients with liver failure awaiting liver transplantation or recovery of liver function. We performed a systematic review to examine the efficacy and safety of 3 albumin dialysis systems (molecular adsorbent recirculating system [MARS], fractionated plasma separation, adsorption and hemodialysis [Prometheus system], and single-pass albumin dialysis) in randomized trials for supportive treatment of liver failure. PubMed, Ovid, EMBASE, Cochrane's Library, and ClinicalTrials.gov were searched. Two authors independently screened citations and extracted data on patient characteristics, quality of reports, efficacy, and safety end points. Ten trials (7 of MARS and 3 of Prometheus) were identified (620 patients). By meta-analysis, albumin dialysis achieved a net decrease in serum total bilirubin level relative to standard medical therapy of 8.0 mg/dL (95% confidence interval [CI], -10.6 to -5.4) but not in serum ammonia or bile acids. Albumin dialysis achieved an improvement in hepatic encephalopathy relative to standard medical therapy with a risk ratio of 1.55 (95% CI, 1.16-2.08) but had no effect survival with a risk ratio of 0.95 (95% CI, 0.84-1.07). Because of inconsistency in the reporting of adverse events, the safety analysis was limited but did not demonstrate major safety concerns. Use of albumin dialysis as supportive treatment for liver failure is successful at removing albumin-bound molecules, such as bilirubin and at improving hepatic encephalopathy. Additional experience is required to guide its optimal use and address safety concerns. Copyright © 2015 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.
Distinctive Left Ventricular Activations Associated With ECG Pattern in Heart Failure Patients.
Derval, Nicolas; Duchateau, Josselin; Mahida, Saagar; Eschalier, Romain; Sacher, Frederic; Lumens, Joost; Cochet, Hubert; Denis, Arnaud; Pillois, Xavier; Yamashita, Seigo; Komatsu, Yuki; Ploux, Sylvain; Amraoui, Sana; Zemmoura, Adlane; Ritter, Philippe; Hocini, Mélèze; Haissaguerre, Michel; Jaïs, Pierre; Bordachar, Pierre
2017-06-01
In contrast to patients with left bundle branch block (LBBB), heart failure patients with narrow QRS and nonspecific intraventricular conduction delay (NICD) display a relatively limited response to cardiac resynchronization therapy. We sought to compare left ventricular (LV) activation patterns in heart failure patients with narrow QRS and NICD to patients with LBBB using high-density electroanatomic activation maps. Fifty-two heart failure patients (narrow QRS [n=18], LBBB [n=11], NICD [n=23]) underwent 3-dimensional electroanatomic mapping with a high density of mapping points (387±349 LV). Adjunctive scar imaging was available in 37 (71%) patients and was analyzed in relation to activation maps. LBBB patients typically demonstrated (1) a single LV breakthrough at the septum (38±15 ms post-QRS onset); (2) prolonged right-to-left transseptal activation with absence of direct LV Purkinje activity; (3) homogeneous propagation within the LV cavity; and (4) latest activation at the basal lateral LV. In comparison, both NICD and narrow QRS patients demonstrated (1) multiple LV breakthroughs along the posterior or anterior fascicles: narrow QRS versus LBBB, 5±2 versus 1±1; P =0.0004; NICD versus LBBB, 4±2 versus 1±1; P =0.001); (2) evidence of early/pre-QRS LV electrograms with Purkinje potentials; (3) rapid propagation in narrow QRS patients and more heterogeneous propagation in NICD patients; and (4) presence of limited areas of late activation associated with LV scar with high interindividual heterogeneity. In contrast to LBBB patients, narrow QRS and NICD patients are characterized by distinct mechanisms of LV activation, which may predict poor response to cardiac resynchronization therapy. © 2017 American Heart Association, Inc.
Quantifying Pilot Contribution to Flight Safety during Drive Shaft Failure
NASA Technical Reports Server (NTRS)
Kramer, Lynda J.; Etherington, Tim; Last, Mary Carolyn; Bailey, Randall E.; Kennedy, Kellie D.
2017-01-01
Accident statistics cite the flight crew as a causal factor in over 60% of large transport aircraft fatal accidents. Yet, a well-trained and well-qualified pilot is acknowledged as the critical center point of aircraft systems safety and an integral safety component of the entire commercial aviation system. The latter statement, while generally accepted, cannot be verified because little or no quantitative data exists on how and how many accidents/incidents are averted by crew actions. A joint NASA/FAA high-fidelity motion-base simulation experiment specifically addressed this void by collecting data to quantify the human (pilot) contribution to safety-of-flight and the methods they use in today's National Airspace System. A human-in-the-loop test was conducted using the FAA's Oklahoma City Flight Simulation Branch Level D-certified B-737-800 simulator to evaluate the pilot's contribution to safety-of-flight during routine air carrier flight operations and in response to aircraft system failures. These data are fundamental to and critical for the design and development of future increasingly autonomous systems that can better support the human in the cockpit. Eighteen U.S. airline crews flew various normal and non-normal procedures over a two-day period and their actions were recorded in response to failures. To quantify the human's contribution to safety of flight, crew complement was used as the experiment independent variable in a between-subjects design. Pilot actions and performance during single pilot and reduced crew operations were measured for comparison against the normal two-crew complement during normal and non-normal situations. This paper details the crew's actions, including decision-making, and responses while dealing with a drive shaft failure - one of 6 non-normal events that were simulated in this experiment.
Lorbach, Olaf; Bachelier, Felix; Vees, Jochen; Kohn, Dieter; Pape, Dietrich
2008-08-01
Double-row repair is suggested to have superior biomechanical properties in rotator cuff reconstruction compared with single-row repair. However, double-row rotator cuff repair is frequently compared with simple suture repair and not with modified suture configurations. Single-row rotator cuff repairs with modified suture configurations have similar failure loads and gap formations as double-row reconstructions. Controlled laboratory study. We created 1 x 2-cm defects in 48 porcine infraspinatus tendons. Reconstructions were then performed with 4 single-row repairs and 2 double-row repairs. The single-row repairs included transosseous simple sutures; double-loaded corkscrew anchors in either a double mattress or modified Mason-Allen suture repair; and the Magnum Knotless Fixation Implant with an inclined mattress. Double-row repairs were either with Bio-Corkscrew FT using modified Mason-Allen stitches or a combination of Bio-Corkscrew FT and PushLock anchors using the SutureBridge Technique. During cyclic load (10 N to 60-200 N), gap formation was measured, and finally, ultimate load to failure and type of failure were recorded. Double-row double-corkscrew anchor fixation had the highest ultimate tensile strength (398 +/- 98 N) compared to simple sutures (105 +/- 21 N; P < .0001), single-row corkscrews using a modified Mason-Allen stitch (256 +/- 73 N; P = .003) or double mattress repair (290 +/- 56 N; P = .043), the Magnum Implant (163 +/- 13 N; P < .0001), and double-row repair with PushLock and Bio-Corkscrew FT anchors (163 +/- 59 N; P < .0001). Single-row double mattress repair was superior to transosseous sutures (P < .0001), the Magnum Implant (P = .009), and double-row repair with PushLock and Bio-Corkscrew FT anchors (P = .009). Lowest gap formation was found for double-row double-corkscrew repair (3.1 +/- 0.1 mm) compared to simple sutures (8.7 +/- 0.2 mm; P < .0001), the Magnum Implant (6.2 +/- 2.2 mm; P = .002), double-row repair with PushLock and Bio-Corkscrew FT anchors (5.9 +/- 0.9 mm; P = .008), and corkscrews with modified Mason-Allen sutures (6.4 +/- 1.3 mm; P = .001). Double-row double-corkscrew anchor rotator cuff repair offered the highest failure load and smallest gap formation and provided the most secure fixation of all tested configurations. Double-loaded suture anchors using modified suture configurations achieved superior results in failure load and gap formation compared to simple suture repair and showed similar loads and gap formation with double-row repair using PushLock and Bio-Corkscrew FT anchors. Single-row repair with modified suture configurations may lead to results comparable to several double-row fixations. If double-row repair is used, modified stitches might further minimize gap formation and increase failure load.
NASA Astrophysics Data System (ADS)
Ravishankar, Bharani
Conventional space vehicles have thermal protection systems (TPS) that provide protection to an underlying structure that carries the flight loads. In an attempt to save weight, there is interest in an integrated TPS (ITPS) that combines the structural function and the TPS function. This has weight saving potential, but complicates the design of the ITPS that now has both thermal and structural failure modes. The main objectives of this dissertation was to optimally design the ITPS subjected to thermal and mechanical loads through deterministic and reliability based optimization. The optimization of the ITPS structure requires computationally expensive finite element analyses of 3D ITPS (solid) model. To reduce the computational expenses involved in the structural analysis, finite element based homogenization method was employed, homogenizing the 3D ITPS model to a 2D orthotropic plate. However it was found that homogenization was applicable only for panels that are much larger than the characteristic dimensions of the repeating unit cell in the ITPS panel. Hence a single unit cell was used for the optimization process to reduce the computational cost. Deterministic and probabilistic optimization of the ITPS panel required evaluation of failure constraints at various design points. This further demands computationally expensive finite element analyses which was replaced by efficient, low fidelity surrogate models. In an optimization process, it is important to represent the constraints accurately to find the optimum design. Instead of building global surrogate models using large number of designs, the computational resources were directed towards target regions near constraint boundaries for accurate representation of constraints using adaptive sampling strategies. Efficient Global Reliability Analyses (EGRA) facilitates sequentially sampling of design points around the region of interest in the design space. EGRA was applied to the response surface construction of the failure constraints in the deterministic and reliability based optimization of the ITPS panel. It was shown that using adaptive sampling, the number of designs required to find the optimum were reduced drastically, while improving the accuracy. System reliability of ITPS was estimated using Monte Carlo Simulation (MCS) based method. Separable Monte Carlo method was employed that allowed separable sampling of the random variables to predict the probability of failure accurately. The reliability analysis considered uncertainties in the geometry, material properties, loading conditions of the panel and error in finite element modeling. These uncertainties further increased the computational cost of MCS techniques which was also reduced by employing surrogate models. In order to estimate the error in the probability of failure estimate, bootstrapping method was applied. This research work thus demonstrates optimization of the ITPS composite panel with multiple failure modes and large number of uncertainties using adaptive sampling techniques.
NASA Technical Reports Server (NTRS)
Arakere, Nagaraj K.; Swanson, Gregory R.
2000-01-01
High Cycle Fatigue (HCF) induced failures in aircraft gas-turbine engines is a pervasive problem affecting a wide range of components and materials. HCF is currently the primary cause of component failures in gas turbine aircraft engines. Turbine blades in high performance aircraft and rocket engines are increasingly being made of single crystal nickel superalloys. Single-crystal Nickel-base superalloys were developed to provide superior creep, stress rupture, melt resistance and thermomechanical fatigue capabilities over polycrystalline alloys previously used in the production of turbine blades and vanes. Currently the most widely used single crystal turbine blade superalloys are PWA 1480/1493 and PWA 1484. These alloys play an important role in commercial, military and space propulsion systems. PWA1493, identical to PWA1480, but with tighter chemical constituent control, is used in the NASA SSME (Space Shuttle Main Engine) alternate turbopump, a liquid hydrogen fueled rocket engine. Objectives for this paper are motivated by the need for developing failure criteria and fatigue life evaluation procedures for high temperature single crystal components, using available fatigue data and finite element modeling of turbine blades. Using the FE (finite element) stress analysis results and the fatigue life relations developed, the effect of variation of primary and secondary crystal orientations on life is determined, at critical blade locations. The most advantageous crystal orientation for a given blade design is determined. Results presented demonstrates that control of secondary and primary crystallographic orientation has the potential to optimize blade design by increasing its resistance to fatigue crack growth without adding additional weight or cost.
Law, Yuk Ming; Ettedgui, Jose; Beerman, Lee; Maisel, Alan; Tofovic, Stevan
2006-08-15
The measurement of plasma B-type natriuretic peptide (BNP) has emerged as a useful biomarker of heart failure in patients with cardiomyopathy. The pathophysiology of heart failure in single ventricle (SV) circulation may be distinct from that of cardiomyopathies. A distinct pattern of BNP elevation in heart failure in the SV population was hypothesized: it is elevated in heart failure secondary to ventricular dysfunction but not in isolated cavopulmonary failure. BNP was measured prospectively in SV patients at catheterization (n = 22) and when assessing for heart failure (n = 11) (7 normal controls). Of 33 SV subjects (median age 62 months), 13 had aortopulmonary connections and 20 had cavopulmonary connections. Median and mean +/- SD BNP levels by shunt type were 184 and 754 +/- 1,086 pg/ml in the patients with aortopulmonary connections, 38 and 169 +/- 251 pg/ml in the patients with cavopulmonary connections, and 10 and 11 +/- 5 pg/ml in normal controls, respectively (p = 0.004). Median systemic ventricular end-diastolic pressure (8mm Hg, R = 0.45), mean pulmonary artery pressure (14.5 mm Hg, R = 0.62), and mean right atrial pressure (6.5 mm Hg, R = 0.54) were correlated with plasma BNP. SV subjects with symptomatic heart failure from dysfunctional systemic ventricles had median and mean +/- SD BNP levels of 378 and 714 +/- 912 pg/ml (n = 18) compared with patients with isolated failed Glenn or Fontan connections (19 and 23 +/- 16 pg/ml [n = 7, p = 0.001]) and those with no heart failure (22 and 22 +/- 12 pg/ml [n = 8, p = 0.001]). Excluding the group with cavopulmonary failure, the severity of heart failure from systemic ventricular dysfunction was associated with plasma BNP. In conclusion, plasma BNP is elevated in SV patients with systemic ventricular or left-sided cardiac failure. BNP is not elevated in patients missing a pulmonary ventricle with isolated cavopulmonary failure.
Long-term anaerobic digestion of food waste stabilized by trace elements
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang Lei, E-mail: wxzyfx@yahoo.com; Jahng, Deokjin, E-mail: djahng@mju.ac.kr
Highlights: Black-Right-Pointing-Pointer Korean food waste was found to contain low level of trace elements. Black-Right-Pointing-Pointer Stable anaerobic digestion of food waste was achieved by adding trace elements. Black-Right-Pointing-Pointer Iron played an important role in anaerobic digestion of food waste. Black-Right-Pointing-Pointer Cobalt addition further enhanced the process performance in the presence of iron. - Abstract: The purpose of this study was to examine if long-term anaerobic digestion of food waste in a semi-continuous single-stage reactor could be stabilized by supplementing trace elements. Contrary to the failure of anaerobic digestion of food waste alone, stable anaerobic digestion of food waste was achievedmore » for 368 days by supplementing trace elements. Under the conditions of OLR (organic loading rates) of 2.19-6.64 g VS (volatile solid)/L day and 20-30 days of HRT (hydraulic retention time), a high methane yield (352-450 mL CH{sub 4}/g VS{sub added}) was obtained, and no significant accumulation of volatile fatty acids was observed. The subsequent investigation on effects of individual trace elements (Co, Fe, Mo and Ni) showed that iron was essential for maintaining stable methane production. These results proved that the food waste used in this study was deficient in trace elements.« less
Revisiting control establishments for emerging energy hubs
NASA Astrophysics Data System (ADS)
Nasirian, Vahidreza
Emerging small-scale energy systems, i.e., microgrids and smartgrids, rely on centralized controllers for voltage regulation, load sharing, and economic dispatch. However, the central controller is a single-point-of-failure in such a design as either the controller or attached communication links failure can render the entire system inoperable. This work seeks for alternative distributed control structures to improve system reliability and help to the scalability of the system. A cooperative distributed controller is proposed that uses a noise-resilient voltage estimator and handles global voltage regulation and load sharing across a DC microgrid. Distributed adaptive droop control is also investigated as an alternative solution. A droop-free distributed control is offered to handle voltage/frequency regulation and load sharing in AC systems. This solution does not require frequency measurement and, thus, features a fast frequency regulation. Distributed economic dispatch is also studied, where a distributed protocol is designed that controls generation units to merge their incremental costs into a consensus and, thus, push the entire system to generate with the minimum cost. Experimental verifications and Hardware-in-the-Loop (HIL) simulations are used to study efficacy of the proposed control protocols.
Al-Mufti, Fawaz; Bauerschmidt, Andrew; Claassen, Jan; Meyers, Philip M; Colombo, Paolo C; Willey, Joshua Z
2016-04-01
With the shortage of donor hearts, increasingly more patients with end-stage heart failure are implanted with left ventricular assist devices (LVADs). LVADs are associated with a significant risk of developing acute ischemic strokes (AISs). Very little is known on about the management of AIS in patients with LVAD, especially with regard to the safety and efficacy of neuroendovascular techniques. We identified 5 patients with heart failure and LVAD implants who developed AIS and underwent neuroendovascular interventions at Columbia University Medical Center. Their cases were reviewed for the safety, efficacy of the interventions, and potential complications. There were no significant complications from the interventions. In all 5 cases, there was at least a 4-point improvement in the National Institutes of Health Stroke scale and none of the cases developed symptomatic hemorrhage. Two patients had substantial improvement and received cardiac transplantations. Neuroendovascular intervention is safe and feasible in patients with LVAD and may potentially contribute to improving the outcome of a disease that has a poor natural history. Further study is recommended. Copyright © 2016 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Sin, Yongkun; Ayvazian, Talin; Brodie, Miles; Lingley, Zachary
2018-03-01
High-power single-mode (SM) and multi-mode (MM) InGaAs-AlGaAs strained quantum well (QW) lasers are critical components for both terrestrial and space satellite communications systems. Since these lasers predominantly fail by catastrophic and sudden degradation due to catastrophic optical damage (COD), it is especially crucial for space satellite applications to investigate reliability, failure modes, precursor signatures of failure, and degradation mechanisms of these lasers. Our group reported a new failure mode in MM and SM InGaAs-AlGaAs strained QW lasers in 2009 and 2016, respectively. Our group also reported in 2017 that bulk failure due to catastrophic optical bulk damage (COBD) is the dominant failure mode of both SM and MM lasers that were subject to long-term life-tests. For the present study, we continued our physics of failure investigation by performing long-term life-tests followed by failure mode analysis (FMA) using nondestructive and destructive micro-analytical techniques. We performed long-term accelerated life-tests on state-of-the-art SM and MM InGaAs- AlGaAs strained QW lasers under ACC mode. Our life-tests have accumulated over 25,000 test hours for SM lasers and over 35,000 test hours for MM lasers. We first employed electron beam induced current (EBIC) technique to identify failure modes of degraded SM lasers by observing dark line defects. All the SM failures that we studied showed catastrophic and sudden degradation and all of these failures were bulk failures. Since degradation mechanisms responsible for COBD are still not well understood, we also employed other techniques including focused ion beam (FIB) and high-resolution TEM to further study dark line defects and dislocations in post-aged lasers. Keywor
NASA Astrophysics Data System (ADS)
Gan, Luping; Li, Yan-Feng; Zhu, Shun-Peng; Yang, Yuan-Jian; Huang, Hong-Zhong
2014-06-01
Failure mode, effects and criticality analysis (FMECA) and Fault tree analysis (FTA) are powerful tools to evaluate reliability of systems. Although single failure mode issue can be efficiently addressed by traditional FMECA, multiple failure modes and component correlations in complex systems cannot be effectively evaluated. In addition, correlated variables and parameters are often assumed to be precisely known in quantitative analysis. In fact, due to the lack of information, epistemic uncertainty commonly exists in engineering design. To solve these problems, the advantages of FMECA, FTA, fuzzy theory, and Copula theory are integrated into a unified hybrid method called fuzzy probability weighted geometric mean (FPWGM) risk priority number (RPN) method. The epistemic uncertainty of risk variables and parameters are characterized by fuzzy number to obtain fuzzy weighted geometric mean (FWGM) RPN for single failure mode. Multiple failure modes are connected using minimum cut sets (MCS), and Boolean logic is used to combine fuzzy risk priority number (FRPN) of each MCS. Moreover, Copula theory is applied to analyze the correlation of multiple failure modes in order to derive the failure probabilities of each MCS. Compared to the case where dependency among multiple failure modes is not considered, the Copula modeling approach eliminates the error of reliability analysis. Furthermore, for purpose of quantitative analysis, probabilities importance weight from failure probabilities are assigned to FWGM RPN to reassess the risk priority, which generalize the definition of probability weight and FRPN, resulting in a more accurate estimation than that of the traditional models. Finally, a basic fatigue analysis case drawn from turbine and compressor blades in aeroengine is used to demonstrate the effectiveness and robustness of the presented method. The result provides some important insights on fatigue reliability analysis and risk priority assessment of structural system under failure correlations.
Burkhart, Stephen S; Denard, Patrick J; Konicek, John; Hanypsiak, Bryan T
2014-02-01
Poor-quality tendon is one of the most difficult problems the surgeon must overcome in achieving secure fixation during rotator cuff repair. A load-sharing rip-stop construct (LSRS) has recently been proposed as a method for improving fixation strength, but the biomechanical properties of this construct have not yet been examined. To compare the strength of the LSRS construct to that of single-row fixation for rotator cuff repair. Controlled laboratory study. Rotator cuff tears were created in 6 cadaveric matched-pair specimens and repaired with a single row or an LSRS. In the LSRS repair, a 2-mm suture tape was placed as an inverted mattress stitch in the rotator cuff, and sutures from 2 anchors were placed as simple stitches that passed medial to the suture tape. The suture tape limbs were secured with knotless anchors laterally before sutures were tied from the medial anchors. Displacement was observed with video tracking after cyclic loading, and specimens were loaded to failure. The mean load to failure was 371 ± 102 N in single-row repairs compared with 616 ± 185 N in LSRS repairs (P = .031). There was no difference in displacement with cyclic loading between the groups (3.3 ± 0.8 mm vs. 3.5 ± 1.1 mm; P = .561). In the single-row group, 4 of 6 failures occurred at the suture-tendon interface. In the LSRS group, only 1 failure occurred at the suture-tendon interface. The ultimate failure load of the LSRS construct for rotator cuff repair was 1.7 times that of a single-row construct in a cadaveric model. The LSRS rotator cuff repair construct may be useful in the repair of difficult tears such as massive tears, medial tears, and tears with tendon loss.
POF-Darts: Geometric adaptive sampling for probability of failure
Ebeida, Mohamed S.; Mitchell, Scott A.; Swiler, Laura P.; ...
2016-06-18
We introduce a novel technique, POF-Darts, to estimate the Probability Of Failure based on random disk-packing in the uncertain parameter space. POF-Darts uses hyperplane sampling to explore the unexplored part of the uncertain space. We use the function evaluation at a sample point to determine whether it belongs to failure or non-failure regions, and surround it with a protection sphere region to avoid clustering. We decompose the domain into Voronoi cells around the function evaluations as seeds and choose the radius of the protection sphere depending on the local Lipschitz continuity. As sampling proceeds, regions uncovered with spheres will shrink,more » improving the estimation accuracy. After exhausting the function evaluation budget, we build a surrogate model using the function evaluations associated with the sample points and estimate the probability of failure by exhaustive sampling of that surrogate. In comparison to other similar methods, our algorithm has the advantages of decoupling the sampling step from the surrogate construction one, the ability to reach target POF values with fewer samples, and the capability of estimating the number and locations of disconnected failure regions, not just the POF value. Furthermore, we present various examples to demonstrate the efficiency of our novel approach.« less
The final word. OSHA's final ruling offers firm deadlines for infection control.
West, K
1992-03-01
Departments that have put off program development while waiting for the final ruling to be published have a lot of work to do. Many departments have been cited and fined by OSHA in the past year for failure to begin infection-control programs or provide hepatitis-B vaccines to personnel. Under the new budget, OSHA was granted permission to up its fine structure sevenfold--thus, a small fine is $7,000, and the highest fine for a single violation is $70,000. Fines can have a greater impact on a department's budget than implementation of the program over time. A key point to remember is that a strong infection-control program will reduce exposure follow-up costs and worker-compensation claims. Infection control is a win-win situation.
A fully redundant power hinge for LANDSAT-D appendages
NASA Technical Reports Server (NTRS)
Mamrol, F. E.; Matteo, D. N.
1981-01-01
The configuration and testing of a power driven hinge for deployment of the solar array and antenna boom for the LANDSAT-D spacecraft is discussed. The hinge is fully mechanically and electrically redundant and, thereby, can sustain a single point failure of any one motor (or its power supply), speed reducer, or bearing set without loss of its ability to function. This design utilizes the capability of the stepper motor drive to remove the flexibility of the drive train from the joint stiffness equation when the hinge is loaded against its stop. This feature precludes gapping of the joint under spacecraft maneuver loads even in the absence of a latching feature. Thus, retraction is easily accomplished by motor reversal without the need for a solenoid function to remove the latch.
IPS Empress crown system: three-year clinical trial results.
Sorensen, J A; Choi, C; Fanuscu, M I; Mito, W T
1998-02-01
The IPS Empress system is a highly esthetic hot pressed glass ceramic material for fabrication of single crowns. Adhesive cementation of the system not only contributes to the esthetics but is necessary for increased strength of the crown. The purpose of this prospective clinical trials was to evaluate the longevity of 75 adhesively cemented Empress full crowns. An additional aim was to assess the adhesive cementation methodology and potential side effects. At the three-year point, one molar crown fractured for a 1.3 percent failure rate. The resin cementation technique that was employed exhibited a low incidence of microleakage with few clinical side effects. There was a 5.6 percent incidence of post-cementation sensitivity, with all symptoms subsiding by eight weeks. None of the crowns in the study required endodontic therapy.
Anterior Cruciate Ligament Injury, Reconstruction, and the Optimization of Outcome
Bliss, James Philip
2017-01-01
Anterior cruciate ligament reconstruction (ACLR) provides an established surgical intervention to control pathological tibiofemoral translational and rotational movement. ACLR is a safe and reproducible intervention, but there remains an underlying rate of failure to return to preinjury sporting activity levels. Postoperative pathological laxity and graft reinjury remain concerns. Previously, unrecognized meniscal lesions, disruption of the lateral capsule, and extracapsular structures offer potential avenues to treat and to therefore improve kinematic outcome and functional results, following reconstruction. Addressing laterally based injuries may also improve the durability of intraarticular ACLR. Improving the anterior cruciate ligament (ACL) graft replication of the normal ACL attachment points on the femur and the tibia, using either double bundle or anatomical single bundle techniques, improves kinematics, which may benefit outcome and functionality, following reconstruction. PMID:28966384
"Reliability Of Fiber Optic Lans"
NASA Astrophysics Data System (ADS)
Code n, Michael; Scholl, Frederick; Hatfield, W. Bryan
1987-02-01
Fiber optic Local Area Network Systems are being used to interconnect increasing numbers of nodes. These nodes may include office computer peripherals and terminals, PBX switches, process control equipment and sensors, automated machine tools and robots, and military telemetry and communications equipment. The extensive shared base of capital resources in each system requires that the fiber optic LAN meet stringent reliability and maintainability requirements. These requirements are met by proper system design and by suitable manufacturing and quality procedures at all levels of a vertically integrated manufacturing operation. We will describe the reliability and maintainability of Codenoll's passive star based systems. These include LAN systems compatible with Ethernet (IEEE 802.3) and MAP (IEEE 802.4), and software compatible with IBM Token Ring (IEEE 802.5). No single point of failure exists in this system architecture.
Successful Women Superintendents: Developing as Leaders, Learning from Failure.
ERIC Educational Resources Information Center
Pankake, Anita M.; Schroth, Gwen; Funk, Carole
2000-01-01
In a Texas study, six successful women superintendents identified vision, passion and commitment, promotion of leadership in others, integrity, knowledge, and stamina as important leadership qualities. Family support, varied work experiences, mentors, formal education, turning points, and failure played important roles in their leadership…
Esquivel, Amanda O.; Duncan, Douglas D.; Dobrasevic, Nikola; Marsh, Stephanie M.; Lemos, Stephen E.
2015-01-01
Background: Rotator cuff tendinopathy is a frequent cause of shoulder pain that can lead to decreased strength and range of motion. Failures after using the single-row technique of rotator cuff repair have led to the development of the double-row technique, which is said to allow for more anatomical restoration of the footprint. Purpose: To compare 5 different types of suture patterns while maintaining equality in number of anchors. The hypothesis was that the Mason-Allen–crossed cruciform transosseous-equivalent technique is superior to other suture configurations while maintaining equality in suture limbs and anchors. Study Design: Controlled laboratory study. Methods: A total of 25 fresh-frozen cadaveric shoulders were randomized into 5 suture configuration groups: single-row repair with simple stitch technique; single-row repair with modified Mason-Allen technique; double-row Mason-Allen technique; double-row cross-bridge technique; and double-row suture bridge technique. Load and displacement were recorded at 100 Hz until failure. Stiffness and bone mineral density were also measured. Results: There was no significant difference in peak load at failure, stiffness, maximum displacement at failure, or mean bone mineral density among the 5 suture configuration groups (P < .05). Conclusion: According to study results, when choosing a repair technique, other factors such as number of sutures in the repair should be considered to judge the strength of the repair. Clinical Relevance: Previous in vitro studies have shown the double-row rotator cuff repair to be superior to the single-row repair; however, clinical research does not necessarily support this. This study found no difference when comparing 5 different repair methods, supporting research that suggests the number of sutures and not the pattern can affect biomechanical properties. PMID:26665053
Ianuzzi, Allyson; Pickar, Joel G; Khalsa, Partap S
2009-01-01
Quadruped animal models have been validated and used as biomechanical models for the lumbar spine. The biomechanics of the cat lumbar spine has not been well characterized, even though it is a common model used in neuromechanical studies. Compare the physiological ranges of motion and determine torque-limits for cat and human lumbar spine specimens during physiological motions. Biomechanics study. Cat and human lumbar spine specimens. Intervertebral angle (IVA), joint moment, yield point, torque-limit, and correlation coefficients. Cat (L2-sacrum) and human (T12-sacrum) lumbar spine specimens were mechanically tested to failure during displacement-controlled extension (E), lateral bending (LB), and axial rotation (AR). Single trials consisted of 10 cycles (10mm/s or 5 degrees /s) to a target displacement where the magnitude of the target displacement was increased for subsequent trials until failure occurred. Whole-lumbar stiffness, torque at yield point, and joint stiffness were determined. Scaling relationships were established using equations analogous to those that describe the load response of elliptically shaped beams. IVA magnitudes for cat and human lumbar spines were similar during physiological motions. Human whole-lumbar and joint stiffness magnitudes were significantly greater than those for cat spine specimens (p<.05). Torque-limits were also greater for humans compared with cats. Scaling relationships with high correlation (R(2) greater than 0.77) were established during later LB and AR. The current study defined "physiological ranges of movement" for human and cat lumbar spine specimens during displacement-controlled testing, and should be observed in future biomechanical studies conducted under displacement control.
NASA Astrophysics Data System (ADS)
Redkar, R. T.
1993-02-01
A new grade of balloon film extruded out of LLDPE resin with Butene as comonomer and Cold Brittle Point (CBP) at -88°C was extruded and successfully flight tested with a 25 micron single shell 53,000 Cu.M. balloon carrying 330 Kg. payload to 33 Km. altitude. We have also produced superior LLDPE film out of Dowlex 2045 Dow Chemicals resin with Octene as comonomer, which has the cold brittle point lower than -90°C and superior mechanical properties at low temperatures. A high pressure hydrogen filling system capable of delivering 2200 Cu.Ft. of hydrogen per minute has been commissioned and successfully utilised in 11 flights. With this new filling system, the inflation time is drastically reduced by over 50% thereby reducing the duration of pre-launch stresses on the ground bubble. After the acceptance of our revised design criteria for balloons to be flown from equatorial latitudes by M/s.Winzen International Inc., U.S.A., 41 flights have been made, out of which 36 have been successful giving us a success record of 88%. Out of the 5 failures, 3 have been float failures with gross inflations exceeding 1950 kg, for which launch spool damage is a suspect. To reduce the spool damage, the shell thickness of the subsequent balloon was increased to 20.32 microns from 17.78 microns and the flight was a success. For further reducing the possibility of launch spool damage, a larger diameter spool is being designed.
Microcircuit Device Reliability Memory/Digital LSI
1982-01-01
has been performed. Each failure event record reveals the particular device and test characteristics, as well as associated stress values and other...given by: « s logio (Vxp) where X0 is the observed failure rate Xp is the predicted failure rate « is the residual Values of « are then plotted...n...... ||^||tpMMMWiWMM*i»""l’’ iŕŕ" ’• of failures per point). Some "funnelling" in Figure 17 shows this, although there is a fair amount of
Folsom, Aaron R.; Shah, Amil M.; Lutsey, Pamela L.; Roetker, Nicholas S.; Alonso, Alvaro; Avery, Christy L.; Miedema, Michael D.; Konety, Suma; Chang, Patricia P.; Solomon, Scott D.
2015-01-01
BACKGROUND Many people may underappreciate the role of lifestyle in avoiding heart failure. We estimated whether greater adherence in middle age to American Heart Association’s Life’s Simple 7 guidelines -- on smoking, body mass, physical activity, diet, cholesterol, blood pressure, and glucose -- is associated with lower lifetime risk of heart failure and greater preservation of cardiac structure and function in old age. METHODS We studied the population-based Atherosclerosis Risk in Communities Study cohort of 13,462 adults aged 45-64 years in 1987-89. From the 1987-89 risk factor measurements, we created a Life’s Simple 7 score (range 0-14, giving 2 points for ideal, 1 point for intermediate, and 0 points for poor components). We identified 2,218 incident heart failure events using surveillance of hospital discharge and death codes through 2011. In addition, in 4,855 participants free of clinical cardiovascular disease in 2011-13, we performed echocardiography from which we quantified left ventricular hypertrophy and diastolic dysfunction. RESULTS One in four participants (25.5%) developed heart failure through age 85. Yet, this lifetime heart failure risk was 14.4% for those with a middle-age Life’s Simple 7 score of 10-14 (optimal), 26.8% for a score of 5-9 (average), and 48.6% for a score of 0-4 (inadequate). Among those with no clinical cardiovascular event, the prevalence of left ventricular hypertrophy in late life was approximately 40% as common, and diastolic dysfunction was approximately 60% as common, among those with an optimal middle-age Life’s Simple 7 score compared with an inadequate score. CONCLUSIONS Greater achievement of American Heart Association’s Life’s Simple 7 in middle-age is associated with a lower lifetime occurrence of heart failure and greater preservation of cardiac structure and function. PMID:25908393
Angermann, Christiane E; Störk, Stefan; Gelbrich, Götz; Faller, Hermann; Jahns, Roland; Frantz, Stefan; Loeffler, Markus; Ertl, Georg
2012-01-01
Trials investigating efficacy of disease management programs (DMP) in heart failure reported contradictory results. Features rendering specific interventions successful are often ill defined. We evaluated the mode of action and effects of a nurse-coordinated DMP (HeartNetCare-HF, HNC). Patients hospitalized for systolic heart failure were randomly assigned to HNC or usual care (UC). Besides telephone-based monitoring and education, HNC addressed individual problems raised by patients, pursued networking of health care providers and provided training for caregivers. End points were time to death or rehospitalization (combined primary), heart failure symptoms, and quality of life (SF-36). Of 1007 consecutive patients, 715 were randomly assigned (HNC: n=352; UC: n=363; age, 69±12 years; 29% female; 40% New York Heart Association class III-IV). Within 180 days, 130 HNC and 137 UC patients reached the primary end point (hazard ratio, 1.02; 95% confidence interval, 0.81-1.30; P=0.89), since more HNC patients were readmitted. Overall, 32 HNC and 52 UC patients died (1 UC patient and 4 HNC patients after dropout); thus, uncensored hazard ratio was 0.62 (0.40-0.96; P=0.03). HNC patients improved more regarding New York Heart Association class (P=0.05), physical functioning (P=0.03), and physical health component (P=0.03). Except for HNC, health care utilization was comparable between groups. However, HNC patients requested counseling for noncardiac problems even more frequently than for cardiovascular or heart-failure-related issues. The primary end point of this study was neutral. However, mortality risk and surrogates of well-being improved significantly. Quantitative assessment of patient requirements suggested that besides (tele)monitoring individualized care considering also noncardiac problems should be integrated in efforts to achieve more sustainable improvement in heart failure outcomes. URL: http://www.controlled-trials.com. Unique identifier: ISRCTN23325295.
Barber, F Alan; Herbert, Morley A; Schroeder, F Alexander; Aziz-Jacobo, Jorge; Mays, Matthew M; Rapley, Jay H
2010-03-01
To evaluate the strength and suture-tendon interface security of various suture anchors triply and doubly loaded with ultrahigh-molecular weight polyethylene-containing sutures and to evaluate the relative effectiveness of placing these anchors in a single-row or double-row arrangement by cyclic loading and then destructive testing. The infraspinatus muscle was reattached to the original humeral footprint by use of 1 of 5 different repair patterns in 40 bovine shoulders. Two single-row repairs and three double-row repairs were tested. High-strength sutures were used for all repairs. Five groups were studied: group 1, 2 triple-loaded screw suture anchors in a single row with simple stitches; group 2, 2 triple-loaded screw anchors in a single row with simple stitches over a fourth suture passed perpendicularly ("rip-stop" stitch); group 3, 2 medial and 2 lateral screw anchors with a single vertical mattress stitch passed from the medial anchors and 2 simple stitches passed from the lateral anchors; group 4, 2 medial double-loaded screw anchors tied in 2 mattress stitches and 2 push-in lateral anchors capturing the medial sutures in a "crisscross" spanning stitch; and group 5, 2 medial double-loaded screw anchors tied in 2 mattress stitches and 2 push-in lateral anchors creating a "suture-bridge" stitch. The specimens were cycled between 10 and 180 N at 1.0 Hz for 3,500 cycles or until failure. Endpoints were cyclic loading displacement (5 and 10 mm), total displacement, and ultimate failure load. A single row of triply loaded anchors was more resistant to stretching to a 5- and 10-mm gap than the double-row repairs with or without the addition of a rip-stop suture (P < .05). The addition of a rip-stop stitch made the repair more resistant to gap formation than a double row repair (P < .05). The crisscross double row created by 2 medial double-loaded suture anchors and 2 lateral push-in anchors stretched more than any other group (P < .05). Double-row repairs with either crossing sutures or 4 separate anchor points were more likely to fail (5- or 10-mm gap) than a single-row repair loaded with 3 simple sutures. The triple-loaded anchors with ultrahigh-molecular weight polyethylene-containing sutures placed in a single row were more resistant to stretching than the double-row groups. Copyright 2010 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Goldstein, Brahm; Giroir, Brett; Randolph, Adrienne
2005-01-01
Although general definitions of the sepsis continuum have been published for adults, no such work has been done for the pediatric population. Physiologic and laboratory variables used to define the systemic inflammatory response syndrome (SIRS) and organ dysfunction require modification for the developmental stages of children. An international panel of 20 experts in sepsis and clinical research from five countries (Canada, France, Netherlands, United Kingdom, and United States) was convened to modify the published adult consensus definitions of infection, sepsis, severe sepsis, septic shock, and organ dysfunction for children. Consensus conference. This document describes the issues surrounding consensus on four major questions addressed at the meeting: a) How should the pediatric age groups affected by sepsis be delineated? b) What are the specific definitions of pediatric SIRS, infection, sepsis, severe sepsis, and septic shock? c) What are the specific definitions of pediatric organ failure and the validity of pediatric organ failure scores? d) What are the appropriate study populations and study end points required to successfully conduct clinical trials in pediatric sepsis? Five subgroups first met separately and then together to evaluate the following areas: signs and symptoms of sepsis, cell markers, cytokines, microbiological data, and coagulation variables. All conference participants approved the final draft of the proceedings of the meeting. Conference attendees modified the current criteria used to define SIRS and sepsis in adults to incorporate pediatric physiologic variables appropriate for the following subcategories of children: newborn, neonate, infant, child, and adolescent. In addition, the SIRS definition was modified so that either criteria for fever or white blood count had to be met. We also defined various organ dysfunction categories, severe sepsis, and septic shock specifically for children. Although no firm conclusion was made regarding a single appropriate study end point, a novel nonmortality end point, organ failure-free days, was considered optimal for pediatric clinical trials given the relatively low incidence of mortality in pediatric sepsis compared with adult populations. We modified the adult SIRS criteria for children. In addition, we revised definitions of severe sepsis and septic shock for the pediatric population. Our goal is for these first-generation pediatric definitions and criteria to facilitate the performance of successful clinical studies in children with sepsis.
Failure detection in high-performance clusters and computers using chaotic map computations
Rao, Nageswara S.
2015-09-01
A programmable media includes a processing unit capable of independent operation in a machine that is capable of executing 10.sup.18 floating point operations per second. The processing unit is in communication with a memory element and an interconnect that couples computing nodes. The programmable media includes a logical unit configured to execute arithmetic functions, comparative functions, and/or logical functions. The processing unit is configured to detect computing component failures, memory element failures and/or interconnect failures by executing programming threads that generate one or more chaotic map trajectories. The central processing unit or graphical processing unit is configured to detect a computing component failure, memory element failure and/or an interconnect failure through an automated comparison of signal trajectories generated by the chaotic maps.
Yousif, Matthew John; Bicos, James
2017-12-01
The glenohumeral joint is the most commonly dislocated joint in the body. Failure rates of capsulolabral repair have been reported to be approximately 8%. Recent focus has been on restoration of the capsulolabral complex by a double-row capsulolabral repair technique in an effort to decrease redislocation rates after arthroscopic capsulolabral repair. To present a review of the biomechanical literature comparing single- versus double-row capsulolabral repairs and discuss the previous case series of double-row fixation. Narrative review. A simple review of the literature was performed by PubMed search. Only biomechanical studies comparing single- versus double-row capsulolabral repair were included for review. Only those case series and descriptive techniques with clinical results for double-row repair were included in the discussion. Biomechanical comparisons evaluating the native footprint of the labrum demonstrated significantly superior restoration of the footprint through double-row capsulolabral repair compared with single-row repair. Biomechanical comparisons of contact pressure at the repair interface, fracture displacement in bony Bankart lesion, load to failure, and decreased external rotation (suggestive of increased load to failure) were also significantly in favor of double- versus single-row repair. Recent descriptive techniques and case series of double-row fixation have demonstrated good clinical outcomes; however, no comparative clinical studies between single- and double-row repair have assessed functional outcomes. The superiority of double-row capsulolabral repair versus single-row repair remains uncertain because comparative studies assessing clinical outcomes have yet to be performed.
14 CFR 29.59 - Takeoff path: Category A.
Code of Federal Regulations, 2010 CFR
2010-01-01
... addition— (1) The takeoff path must remain clear of the height-velocity envelope established in accordance with § 29.87; (2) The rotorcraft must be flown to the engine failure point; at which point, the...
[Pain, flare-ups and failures in root canal therapy].
Moorer, W R
1989-10-01
In this overview the incidences and causes of pain, flare-ups and failures that occur after root canal therapy are discussed. Infection is considered the most important single, underlying determinant of the many factors that may cause pain and failures. Therefore, strict adherence to recognized therapeutic principles of shaping, disinfection and filling, in addition to proper aftercare, is of importance to diminish postoperative sequelae.
NASA Astrophysics Data System (ADS)
Lachapelle, G.; Cannon, M. E.; Qiu, W.; Varner, C.
1996-09-01
Aircraft single point position accuracy is assessed through a comparison of the single point coordinates with corresponding DGPS-derived coordinates. The platform utilized for this evaluation is a Naval Air Warfare Center P-3 Orion aircraft. Data was collected over a period of about 40 hours, spread over six days, off Florida's East Coast in July 94, using DGPS reference stations in Jacksonville, FL, and Warminster, PA. The analysis of results shows that the consistency between aircraft single point and DGPS coordinates obtained in single point positioning mode and DGPS mode is about 1 m (rms) in latitude and longitude, and 2 m (rms) in height, with instantaneous errors of up to a few metres due to the effect of the ionosphere on the single point L1 solutions.
Simulating fail-stop in asynchronous distributed systems
NASA Technical Reports Server (NTRS)
Sabel, Laura; Marzullo, Keith
1994-01-01
The fail-stop failure model appears frequently in the distributed systems literature. However, in an asynchronous distributed system, the fail-stop model cannot be implemented. In particular, it is impossible to reliably detect crash failures in an asynchronous system. In this paper, we show that it is possible to specify and implement a failure model that is indistinguishable from the fail-stop model from the point of view of any process within an asynchronous system. We give necessary conditions for a failure model to be indistinguishable from the fail-stop model, and derive lower bounds on the amount of process replication needed to implement such a failure model. We present a simple one-round protocol for implementing one such failure model, which we call simulated fail-stop.
Space Shuttle Solid Rocket Booster Decelerator Subsystem Drop Test 3 - Anatomy of a failure
NASA Technical Reports Server (NTRS)
Runkle, R. E.; Woodis, W. R.
1979-01-01
A test failure dramatically points out a design weakness or the limits of the material in the test article. In a low budget test program, with a very limited number of tests, a test failure sparks supreme efforts to investigate, analyze, and/or explain the anomaly and to improve the design such that the failure will not recur. The third air drop of the Space Shuttle Solid Rocket Booster Recovery System experienced such a dramatic failure. On air drop 3, the 54-ft drogue parachute was totally destroyed 0.7 sec after deployment. The parachute failure investigation, based on analysis of drop test data and supporting ground element test results is presented. Drogue design modifications are also discussed.
Greene, Stephen J; Hernandez, Adrian F; Sun, Jie-Lena; Metra, Marco; Butler, Javed; Ambrosy, Andrew P; Ezekowitz, Justin A; Starling, Randall C; Teerlink, John R; Schulte, Phillip J; Voors, Adriaan A; Armstrong, Paul W; O'Connor, Christopher M; Mentz, Robert J
2016-09-01
Most international acute heart failure trials have failed to show benefit with respect to key end points. The impact of site enrollment and protocol execution on trial performance is unclear. We assessed the impact of varying site enrollment volume among all 7141 acute heart failure patients from the ASCEND-HF trial (Acute Study of Clinical Effectiveness of Nesiritide in Decompensated Heart Failure). Overall, 398 sites enrolled ≥1 patient, and median enrollment was 12 patients (interquartile range, 5-23). Patients from high enrolling sites (>60 patients/site) tended to have lower ejection fraction, worse New York Heart Association functional class, and lower utilization of guideline-directed medical therapy but fewer comorbidities and lower B-type natriuretic peptide level. Every 10 patient increase (up to 100 patients) in site enrollment correlated with lower likelihood of protocol noncompletion (odds ratio, 0.93; 95% confidence interval [CI], 0.89-0.98). After adjustment, increasing site enrollment predicted higher risk of persistent dyspnea at 6 hours (per 10 patient increase: odds ratio 1.02; 95% CI, 1.01-1.03) but not at 24 hours (odds ratio, 0.99; 95% CI, 0.98-1.00). Higher site enrollment was independently associated with lower risk of 30-day death or rehospitalization (per 10 patient increase: odds ratio, 0.98, 95% CI, 0.96-0.99) but not 180-day mortality (hazard ratio, 0.99; 95% CI, 0.98-1.01). The influence of increasing site enrollment on clinical end points varied across geographic regions with strongest associations in Latin America and Asia-Pacific (all interaction P<0.01). In this large, acute heart failure trial, site enrollment correlated with protocol completion and was independently associated with trial end points. Individual and regional site performance present challenges to be considered in design of future acute heart failure trials. URL: http://www.clinicaltrials.gov. Unique identifier: NCT00475852. © 2016 American Heart Association, Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ebeida, Mohamed S.; Mitchell, Scott A.; Swiler, Laura P.
We introduce a novel technique, POF-Darts, to estimate the Probability Of Failure based on random disk-packing in the uncertain parameter space. POF-Darts uses hyperplane sampling to explore the unexplored part of the uncertain space. We use the function evaluation at a sample point to determine whether it belongs to failure or non-failure regions, and surround it with a protection sphere region to avoid clustering. We decompose the domain into Voronoi cells around the function evaluations as seeds and choose the radius of the protection sphere depending on the local Lipschitz continuity. As sampling proceeds, regions uncovered with spheres will shrink,more » improving the estimation accuracy. After exhausting the function evaluation budget, we build a surrogate model using the function evaluations associated with the sample points and estimate the probability of failure by exhaustive sampling of that surrogate. In comparison to other similar methods, our algorithm has the advantages of decoupling the sampling step from the surrogate construction one, the ability to reach target POF values with fewer samples, and the capability of estimating the number and locations of disconnected failure regions, not just the POF value. Furthermore, we present various examples to demonstrate the efficiency of our novel approach.« less
NASA Technical Reports Server (NTRS)
McCarty, John P.; Lyles, Garry M.
1997-01-01
Propulsion system quality is defined in this paper as having high reliability, that is, quality is a high probability of within-tolerance performance or operation. Since failures are out-of-tolerance performance, the probability of failures and their occurrence is the difference between high and low quality systems. Failures can be described at 3 levels: the system failure (which is the detectable end of a failure), the failure mode (which is the failure process), and the failure cause (which is the start). Failure causes can be evaluated & classified by type. The results of typing flight history failures shows that most failures are in unrecognized modes and result from human error or noise, i.e. failures are when engineers learn how things really work. Although the study based on US launch vehicles, a sampling of failures from other countries indicates the finding has broad application. The parameters of the design of a propulsion system are not single valued, but have dispersions associated with the manufacturing of parts. Many tests are needed to find failures, if the dispersions are large relative to tolerances, which could contribute to the large number of failures in unrecognized modes.
(n, N) type maintenance policy for multi-component systems with failure interactions
NASA Astrophysics Data System (ADS)
Zhang, Zhuoqi; Wu, Su; Li, Binfeng; Lee, Seungchul
2015-04-01
This paper studies maintenance policies for multi-component systems in which failure interactions and opportunistic maintenance (OM) involve. This maintenance problem can be formulated as a Markov decision process (MDP). However, since an action set and state space in MDP exponentially expand as the number of components increase, traditional approaches are computationally intractable. To deal with curse of dimensionality, we decompose such a multi-component system into mutually influential single-component systems. Each single-component system is formulated as an MDP with the objective of minimising its long-run average maintenance cost. Under some reasonable assumptions, we prove the existence of the optimal (n, N) type policy for a single-component system. An algorithm to obtain the optimal (n, N) type policy is also proposed. Based on the proposed algorithm, we develop an iterative approximation algorithm to obtain an acceptable maintenance policy for a multi-component system. Numerical examples find that failure interactions and OM pose significant effects on a maintenance policy.
NASA Technical Reports Server (NTRS)
2006-01-01
Access 5 analyzed the differences between UAS and manned aircraft operations under five categories of abnormal or emergency situations: Link Failure, Lost Communications, Onboard System Failures, Control Station Failures and Abnormal Weather. These analyses were made from the vantage point of the impact that these operations have on the US air traffic control system, with recommendations for new policies and procedures included where appropriate.
Health Care: A Report on the Industry 2004
2004-06-01
in fact are soaring out of proportion to the quality of care provided to the population as a whole. Market failures prevent the health care industry... failures prevent the health care industry from reaching its best potential efficiency in terms of resource allocation; the disconnect between buyers and...and-a-half points higher than the federal standard), 1,400 service members were discharged for failure to meet the metric in 2002, joining more than
Probability of failure prediction for step-stress fatigue under sine or random stress
NASA Technical Reports Server (NTRS)
Lambert, R. G.
1979-01-01
A previously proposed cumulative fatigue damage law is extended to predict the probability of failure or fatigue life for structural materials with S-N fatigue curves represented as a scatterband of failure points. The proposed law applies to structures subjected to sinusoidal or random stresses and includes the effect of initial crack (i.e., flaw) sizes. The corrected cycle ratio damage function is shown to have physical significance.
Attitude control system of the Delfi-n3Xt satellite
NASA Astrophysics Data System (ADS)
Reijneveld, J.; Choukroun, D.
2013-12-01
This work is concerned with the development of the attitude control algorithms that will be implemented on board of the Delfi-n3xt nanosatellite, which is to be launched in 2013. One of the mission objectives is to demonstrate Sun pointing and three axis stabilization. The attitude control modes and the associated algorithms are described. The control authority is shared between three body-mounted magnetorquers (MTQ) and three orthogonal reaction wheels. The attitude information is retrieved from Sun vector measurements, Earth magnetic field measurements, and gyro measurements. The design of the control is achieved as a trade between simplicity and performance. Stabilization and Sun pointing are achieved via the successive application of the classical Bdot control law and a quaternion feedback control. For the purpose of Sun pointing, a simple quaternion estimation scheme is implemented based on geometric arguments, where the need for a costly optimal filtering algorithm is alleviated, and a single line of sight (LoS) measurement is required - here the Sun vector. Beyond the three-axis Sun pointing mode, spinning Sun pointing modes are also described and used as demonstration modes. The three-axis Sun pointing mode requires reaction wheels and magnetic control while the spinning control modes are implemented with magnetic control only. In addition, a simple scheme for angular rates estimation using Sun vector and Earth magnetic measurements is tested in the case of gyro failures. The various control modes performances are illustrated via extensive simulations over several orbits time spans. The simulated models of the dynamical space environment, of the attitude hardware, and the onboard controller logic are using realistic assumptions. All control modes satisfy the minimal Sun pointing requirements allowed for power generation.
Face landmark point tracking using LK pyramid optical flow
NASA Astrophysics Data System (ADS)
Zhang, Gang; Tang, Sikan; Li, Jiaquan
2018-04-01
LK pyramid optical flow is an effective method to implement object tracking in a video. It is used for face landmark point tracking in a video in the paper. The landmark points, i.e. outer corner of left eye, inner corner of left eye, inner corner of right eye, outer corner of right eye, tip of a nose, left corner of mouth, right corner of mouth, are considered. It is in the first frame that the landmark points are marked by hand. For subsequent frames, performance of tracking is analyzed. Two kinds of conditions are considered, i.e. single factors such as normalized case, pose variation and slowly moving, expression variation, illumination variation, occlusion, front face and rapidly moving, pose face and rapidly moving, and combination of the factors such as pose and illumination variation, pose and expression variation, pose variation and occlusion, illumination and expression variation, expression variation and occlusion. Global measures and local ones are introduced to evaluate performance of tracking under different factors or combination of the factors. The global measures contain the number of images aligned successfully, average alignment error, the number of images aligned before failure, and the local ones contain the number of images aligned successfully for components of a face, average alignment error for the components. To testify performance of tracking for face landmark points under different cases, tests are carried out for image sequences gathered by us. Results show that the LK pyramid optical flow method can implement face landmark point tracking under normalized case, expression variation, illumination variation which does not affect facial details, pose variation, and that different factors or combination of the factors have different effect on performance of alignment for different landmark points.
Yousefinezhadi, Taraneh; Jannesar Nobari, Farnaz Attar; Goodari, Faranak Behzadi; Arab, Mohammad
2016-01-01
Introduction: In any complex human system, human error is inevitable and shows that can’t be eliminated by blaming wrong doers. So with the aim of improving Intensive Care Units (ICU) reliability in hospitals, this research tries to identify and analyze ICU’s process failure modes at the point of systematic approach to errors. Methods: In this descriptive research, data was gathered qualitatively by observations, document reviews, and Focus Group Discussions (FGDs) with the process owners in two selected ICUs in Tehran in 2014. But, data analysis was quantitative, based on failures’ Risk Priority Number (RPN) at the base of Failure Modes and Effects Analysis (FMEA) method used. Besides, some causes of failures were analyzed by qualitative Eindhoven Classification Model (ECM). Results: Through FMEA methodology, 378 potential failure modes from 180 ICU activities in hospital A and 184 potential failures from 99 ICU activities in hospital B were identified and evaluated. Then with 90% reliability (RPN≥100), totally 18 failures in hospital A and 42 ones in hospital B were identified as non-acceptable risks and then their causes were analyzed by ECM. Conclusions: Applying of modified PFMEA for improving two selected ICUs’ processes reliability in two different kinds of hospitals shows that this method empowers staff to identify, evaluate, prioritize and analyze all potential failure modes and also make them eager to identify their causes, recommend corrective actions and even participate in improving process without feeling blamed by top management. Moreover, by combining FMEA and ECM, team members can easily identify failure causes at the point of health care perspectives. PMID:27157162
Corrective osteotomy for cubitus varus in middle-aged patients.
Lim, Tae Kang; Koh, Kyoung Hwan; Lee, Do Kyung; Park, Min Jong
2011-09-01
We reviewed the results of corrective osteotomy for cubitus varus in middle-aged patients to investigate whether it is recommended in this age group. We studied 20 consecutive patients who underwent 3-dimensional corrective osteotomy at an average age of 47.9 years (range, 41-55 years). The osteotomy was fixed with single plating in 8 patients and with double plating in 12. The average follow-up was 23 months (range, 18-109 months). The average humerus-elbow-wrist angle improved from 21.4° (range, 15°-35°) varus to 8.7° (range, -4°-20°) valgus. Osseous union was radiographically demonstrated in all patients at an average of 17.5 weeks (range, 8-36 weeks). Delayed union of longer than 12 weeks was observed in 15 patients (75%). The average time to union in the single-plating group was 21.0 weeks compared with 15.1 weeks in the double-plating group (P = .012). Failure of fixation occurred in 2 patients who had single plating. The preoperative and postoperative arc of motion was similar. According to Oppenheim criteria, results were excellent in 10, good in 8, and poor in 2. The average final Mayo Elbow Performance Score was 90.3 points (range, 70-100 points). Cubitus varus in middle-aged patients can be treated by a closing wedge osteotomy and fixation with double plating. This provides satisfactory deformity correction, maintenance of the elbow motion, and good functional outcome, although healing of the osteotomy tends to be delayed. Copyright © 2011 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.
Three-point bending of honeycomb sandwich beams with facesheet perforations
NASA Astrophysics Data System (ADS)
Su, Pengbo; Han, Bin; Zhao, Zhongnan; Zhang, Qiancheng; Lu, Tian Jian
2017-12-01
A novel square honeycomb-cored sandwich beam with perforated bottom facesheet is investigated under three-point bending, both analytically and numerically. Perforated square holes in the bottom facesheet are characterized by the area ratio of the hole to intact facesheet (perforation ratio). While for large-scale engineering applications like the decks of cargo vehicles and transportation ships, the perforations are needed to facilitate the fabrication process (e.g., laser welding) as well as service maintenance, it is demonstrated that these perforations, when properly designed, can also enhance the resistance of the sandwich to bending. For illustration, fair comparisons among competing sandwich designs having different perforation ratios but equal mass is achieved by systematically thickening the core webs. Further, the perforated sandwich beam is designed with a relatively thick facesheet to avoid local indention failure so that it mainly fails in two competing modes: (1) bending failure, i.e., yielding of beam cross-section and buckling of top facesheet caused by bending moment; (2) shear failure, i.e., yielding and buckling of core webs due to shear forcing. The sensitivity of the failure loads to the ratio of core height to beam span is also discussed for varying perforation ratios. As the perforation ratio is increased, the load of shear failure increases due to thickening core webs, while that of bending failure decreases due to the weakening bottom facesheet. Design of a sandwich beam with optimal perforation ratio is realized when the two failure loads are equal, leading to significantly enhanced failure load (up to 60% increase) relative to that of a non-perforated sandwich beam with equal mass.
Sen, Barun Kumar; Pandit, Alak
2018-01-01
Guillain-Barré syndrome (GBS) has unpredictable clinical course with severe complication of respiratory failure. To identify clinical profiles and electrophysiological study particularly non-invasive Phrenic nerve conduction study in patients of early GBS to predict respiratory failure. 64 adult (age≥18yrs) patients of early GBS (onset ≤ 14 days) during the study period from January 2014 to October 2015 were evaluated by clinical profiles of age, gender, antecedent infection, time to peak disability, single breath counts, cranial nerve involvement, autonomic dysfunction and non-invasive Phrenic nerve conduction study. Patients with predisposition factors of polyneuropathy like diabetes mellitus, hypothyroidism, vitamin deficiency, renal failure were excluded. Among 64 patients abnormal phrenic nerve conduction study was seen in 65.62% cases (42/64) and 45.23% (19/42) of them developed respiratory failure. Phrenic nerve sum latency, amplitude, duration and area were abnormal in those who developed respiratory failure and they had sum of phrenic nerve latency >28 msec, sum of CMAP amplitude <300 μV, sum of CMAP duration >50 msec and sum of area < 4 mVmS. None with normal phrenic nerve study developed respiratory failure. It was found that age, gender, preceding infection, autonomic involvement and types of GB syndrome had no influence on development of respiratory failure (p>0.05). Rapid disease progression to peak disability, more severe disease, shorter single breath counts and cranial nerve involvement were seen more often in patients with respiratory failure. Abnormal Phrenic nerve conduction study in the early Guillain-Barré syndrome might be of great value independently in predicting impending respiratory failure.
Sen, Barun Kumar; Pandit, Alak
2018-01-01
Background: Guillain-Barré syndrome (GBS) has unpredictable clinical course with severe complication of respiratory failure. Objective: To identify clinical profiles and electrophysiological study particularly non-invasive Phrenic nerve conduction study in patients of early GBS to predict respiratory failure. Methods: 64 adult (age≥18yrs) patients of early GBS (onset ≤ 14 days) during the study period from January 2014 to October 2015 were evaluated by clinical profiles of age, gender, antecedent infection, time to peak disability, single breath counts, cranial nerve involvement, autonomic dysfunction and non-invasive Phrenic nerve conduction study. Patients with predisposition factors of polyneuropathy like diabetes mellitus, hypothyroidism, vitamin deficiency, renal failure were excluded. Results: Among 64 patients abnormal phrenic nerve conduction study was seen in 65.62% cases (42/64) and 45.23% (19/42) of them developed respiratory failure. Phrenic nerve sum latency, amplitude, duration and area were abnormal in those who developed respiratory failure and they had sum of phrenic nerve latency >28 msec, sum of CMAP amplitude <300 μV, sum of CMAP duration >50 msec and sum of area < 4 mVmS. None with normal phrenic nerve study developed respiratory failure. It was found that age, gender, preceding infection, autonomic involvement and types of GB syndrome had no influence on development of respiratory failure (p>0.05). Rapid disease progression to peak disability, more severe disease, shorter single breath counts and cranial nerve involvement were seen more often in patients with respiratory failure. Conclusion: Abnormal Phrenic nerve conduction study in the early Guillain-Barré syndrome might be of great value independently in predicting impending respiratory failure. PMID:29720799
NASA Astrophysics Data System (ADS)
Sin, Yongkun; Lingley, Zachary; Brodie, Miles; Presser, Nathan; Moss, Steven C.
2017-02-01
High-power single-mode (SM) and multi-mode (MM) InGaAs-AlGaAs strained quantum well (QW) lasers are critical components for both telecommunications and space satellite communications systems. However, little has been reported on failure modes and degradation mechanisms of high-power SM and MM InGaAs-AlGaAs strained QW lasers although it is crucial to understand failure modes and underlying degradation mechanisms in developing these lasers that meet lifetime requirements for space satellite systems, where extremely high reliability of these lasers is required. Our present study addresses the aforementioned issues by performing long-term life-tests followed by failure mode analysis (FMA) and physics of failure investigation. We performed long-term accelerated life-tests on state-of-the-art SM and MM InGaAs-AlGaAs strained QW lasers under ACC (automatic current control) mode. Our life-tests have accumulated over 25,000 test hours for SM lasers and over 35,000 test hours for MM lasers. FMA was performed on failed SM lasers using electron beam induced current (EBIC). This technique allowed us to identify failure types by observing dark line defects. All the SM failures we studied showed catastrophic and sudden degradation and all of these failures were bulk failures. Our group previously reported that bulk failure or COBD (catastrophic optical bulk damage) is the dominant failure mode of MM InGaAs-AlGaAs strained QW lasers. Since degradation mechanisms responsible for COBD are still not well understood, we also employed other techniques including focused ion beam (FIB) processing and high-resolution TEM to further study dark line defects and dislocations in post-aged lasers. Our long-term life-test results and FMA results are reported.
Extended Testability Analysis Tool
NASA Technical Reports Server (NTRS)
Melcher, Kevin; Maul, William A.; Fulton, Christopher
2012-01-01
The Extended Testability Analysis (ETA) Tool is a software application that supports fault management (FM) by performing testability analyses on the fault propagation model of a given system. Fault management includes the prevention of faults through robust design margins and quality assurance methods, or the mitigation of system failures. Fault management requires an understanding of the system design and operation, potential failure mechanisms within the system, and the propagation of those potential failures through the system. The purpose of the ETA Tool software is to process the testability analysis results from a commercial software program called TEAMS Designer in order to provide a detailed set of diagnostic assessment reports. The ETA Tool is a command-line process with several user-selectable report output options. The ETA Tool also extends the COTS testability analysis and enables variation studies with sensor sensitivity impacts on system diagnostics and component isolation using a single testability output. The ETA Tool can also provide extended analyses from a single set of testability output files. The following analysis reports are available to the user: (1) the Detectability Report provides a breakdown of how each tested failure mode was detected, (2) the Test Utilization Report identifies all the failure modes that each test detects, (3) the Failure Mode Isolation Report demonstrates the system s ability to discriminate between failure modes, (4) the Component Isolation Report demonstrates the system s ability to discriminate between failure modes relative to the components containing the failure modes, (5) the Sensor Sensor Sensitivity Analysis Report shows the diagnostic impact due to loss of sensor information, and (6) the Effect Mapping Report identifies failure modes that result in specified system-level effects.
Acute Respiratory Failure in Renal Transplant Recipients: A Single Intensive Care Unit Experience.
Ulas, Aydin; Kaplan, Serife; Zeyneloglu, Pinar; Torgay, Adnan; Pirat, Arash; Haberal, Mehmet
2015-11-01
Frequency of pulmonary complications after renal transplant has been reported to range from 3% to 17%. The objective of this study was to evaluate renal transplant recipients admitted to an intensive care unit to identify incidence and cause of acute respiratory failure in the postoperative period and compare clinical features and outcomes between those with and without acute respiratory failure. We retrospectively screened the data of 540 consecutive adult renal transplant recipients who received their grafts at a single transplant center and included those patients admitted to an intensive care unit during this period for this study. Acute respiratory failure was defined as severe dyspnea, respiratory distress, decreased oxygen saturation, hypoxemia or hypercapnia on room air, or requirement of noninvasive or invasive mechanical ventilation. Among the 540 adult renal transplant recipients, 55 (10.7%) were admitted to an intensive care unit, including 26 (47.3%) admitted for acute respiratory failure. Median time from transplant to intensive care unit admission was 10 months (range, 0-67 mo). The leading causes of acute respiratory failure were bacterial pneumonia (56%) and cardiogenic pulmonary edema (44%). Mean partial pressure of arterial oxygen to fractional inspired oxygen ratio was 174 ± 59, invasive mechanical ventilation was used in 13 patients (50%), and noninvasive mechanical ventilation was used in 8 patients (31%). The overall mortality was 16.4%. Acute respiratory failure was the reason for intensive care unit admission in almost half of our renal transplant recipients. Main causes of acute respiratory failure were bacterial pneumonia and cardiogenic pulmonary edema. Mortality of patients admitted for acute respiratory failure was similar to those without acute respiratory failure.
Wear of dental tissues and materials.
Craig, R G; Powers, J M
1976-06-01
Wear may result from physiological or pathological conditions and may be desirable, as in the reduction of an overcontoured restoration, or undesirable as in the production of cervical abrasion cavities. A variety of methods, including clinical testing, the use of wear machines and the measurement of related properties such as hardness or coefficient of friction have been used to investigate wear of tooth tissue and of dental materials. Because these methods may not reveal the nature of the wear process recent work has been directed to the study of surface failure resulting from a single sliding contact. Many clinical studies have been conducted but they are time consuming and difficult to quantify, nor do they allow of evaluation of different parameters contributing to the wear. Laboratory simulation of wear has been shown to be valuable in comparing materials of the same group but between-group comparisons may give anomalous results. The most rewarding studies have been those using a single or small number of passes of a suitable abrading point over the material since these permit determination of the actual process by which wear is produced.
De Maria, Elia; Borghi, Ambra; Bonetti, Lorenzo; Fontana, Pier Luigi; Cappelli, Stefano
2017-02-16
Conductor externalization and insulation failure are frequent complications with the recalled St. Jude Medical Riata implantable cardioverter-defibrillator (ICD) leads. Conductor externalization is a "unique" failure mechanism: Cables externalize through the insulation ("inside-out" abrasion) and appear outside the lead body. Recently, single reports described a similar failure also for Biotronik leads. Moreover, some studies reported a high rate of electrical dysfunction (not only insulation failure) with Biotronik Linox leads and a reduced survival rate in comparison with the competitors. In this paper we describe the case of a patient with a Biotronik Kentrox ICD lead presenting with signs of insulation failure and conductor externalization at fluoroscopy. Due to the high risk of extraction we decided to implant a new lead, abandoning the damaged one; lead reimplant was uneventful. Subsequently, we review currently available literature about Biotronik Kentrox and Linox ICD lead failure and in particular externalized conductors. Some single-center studies and a non-prospective registry reported a survival rate between 88% and 91% at 5 years for Linox leads, significantly worse than that of other manufacturers. However, the preliminary results of two ongoing multicenter, prospective registries (GALAXY and CELESTIAL) showed 96% survival rate at 5 years after implant, well within industry standards. Ongoing data collection is needed to confirm longer-term performance of this family of ICD leads.
De Maria, Elia; Borghi, Ambra; Bonetti, Lorenzo; Fontana, Pier Luigi; Cappelli, Stefano
2017-01-01
Conductor externalization and insulation failure are frequent complications with the recalled St. Jude Medical Riata implantable cardioverter-defibrillator (ICD) leads. Conductor externalization is a “unique” failure mechanism: Cables externalize through the insulation (“inside-out” abrasion) and appear outside the lead body. Recently, single reports described a similar failure also for Biotronik leads. Moreover, some studies reported a high rate of electrical dysfunction (not only insulation failure) with Biotronik Linox leads and a reduced survival rate in comparison with the competitors. In this paper we describe the case of a patient with a Biotronik Kentrox ICD lead presenting with signs of insulation failure and conductor externalization at fluoroscopy. Due to the high risk of extraction we decided to implant a new lead, abandoning the damaged one; lead reimplant was uneventful. Subsequently, we review currently available literature about Biotronik Kentrox and Linox ICD lead failure and in particular externalized conductors. Some single-center studies and a non-prospective registry reported a survival rate between 88% and 91% at 5 years for Linox leads, significantly worse than that of other manufacturers. However, the preliminary results of two ongoing multicenter, prospective registries (GALAXY and CELESTIAL) showed 96% survival rate at 5 years after implant, well within industry standards. Ongoing data collection is needed to confirm longer-term performance of this family of ICD leads. PMID:28255544
Foust, Amanda; Popovic, Marko; Zecevic, Dejan; McCormick, David A.
2010-01-01
Purkinje neurons are the output cells of the cerebellar cortex and generate spikes in two distinct modes, known as simple and complex spikes. Revealing the point of origin of these action potentials, and how they conduct into local axon collaterals, is important for understanding local and distal neuronal processing and communication. By utilizing a recent improvement in voltage sensitive dye imaging technique that provided exceptional spatial and temporal resolution, we were able to resolve the region of spike initiation as well as follow spike propagation into axon collaterals for each action potential initiated on single trials. All fast action potentials, for both simple and complex spikes, whether occurring spontaneously or in response to a somatic current pulse or synaptic input, initiated in the axon initial segment. At discharge frequencies of less than approximately 250 Hz, spikes propagated faithfully through the axon and axon collaterals, in a saltatory manner. Propagation failures were only observed for very high frequencies or for the spikelets associated with complex spikes. These results demonstrate that the axon initial segment is a critical decision point in Purkinje cell processing and that the properties of axon branch points are adjusted to maintain faithful transmission. PMID:20484631
NASA Astrophysics Data System (ADS)
Lansard, Erick; Frayssinhes, Eric; Palmade, Jean-Luc
Basically, the problem of designing a multisatellite constellation exhibits a lot of parameters with many possible combinations: total number of satellites, orbital parameters of each individual satellite, number of orbital planes, number of satellites in each plane, spacings between satellites of each plane, spacings between orbital planes, relative phasings between consecutive orbital planes. Hopefully, some authors have theoretically solved this complex problem under simplified assumptions: the permanent (or continuous) coverage by a single and multiple satellites of the whole Earth and zonal areas has been entirely solved from a pure geometrical point of view. These solutions exhibit strong symmetry properties (e.g. Walker, Ballard, Rider, Draim constellations): altitude and inclination are identical, orbital planes and satellites are regularly spaced, etc. The problem with such constellations is their oversimplified and restricted geometrical assumption. In fact, the evaluation function which is used implicitly only takes into account the point-to-point visibility between users and satellites and does not deal with very important constraints and considerations that become mandatory when designing a real satellite system (e.g. robustness to satellite failures, total system cost, common view between satellites and ground stations, service availability and satellite reliability, launch and early operations phase, production constraints, etc.). An original and global methodology relying on a powerful optimization tool based on genetic algorithms has been developed at ALCATEL ESPACE. In this approach, symmetrical constellations can be used as initial conditions of the optimization process together with specific evaluation functions. A multi-criteria performance analysis is conducted and presented here in a parametric way in order to identify and evaluate the main sensitive parameters. Quantitative results are given for three examples in the fields of navigation, telecommunication and multimedia satellite systems. In particular, a new design pattern with very efficient properties in terms of robustness to satellite failures is presented and compared with classical Walker patterns.
Rydman, Riikka; Gatzoulis, Michael A; Ho, Siew Yen; Ernst, Sabine; Swan, Lorna; Li, Wei; Wong, Tom; Sheppard, Mary; McCarthy, Karen P; Roughton, Michael; Kilner, Philip J; Pennell, Dudley J; Babu-Narayan, Sonya V
2015-05-01
We hypothesized that fibrosis detected by late gadolinium enhancement (LGE) cardiovascular magnetic resonance predicts outcomes in patients with transposition of the great arteries post atrial redirection surgery. These patients have a systemic right ventricle (RV) and are at risk of arrhythmia, premature RV failure, and sudden death. Fifty-five patients (aged 27±7 years) underwent LGE cardiovascular magnetic resonance and were followed for a median 7.8 (interquartile range, 3.8-9.6) years in a prospective single-center cohort study. RV LGE was present in 31 (56%) patients. The prespecified composite clinical end point comprised new-onset sustained tachyarrhythmia (atrial/ventricular) or decompensated heart failure admission/transplantation/death. Univariate predictors of the composite end point (n=22 patients; 19 atrial/2 ventricular tachyarrhythmia, 1 death) included RV LGE presence and extent, RV volumes/mass/ejection fraction, right atrial area, peak Vo(2), and age at repair. In bivariate analysis, RV LGE presence was independently associated with the composite end point (hazard ratio, 4.95 [95% confidence interval, 1.60-15.28]; P=0.005), and only percent predicted peak Vo(2) remained significantly associated with cardiac events after controlling for RV LGE (hazard ratio, 0.80 [95% confidence interval, 0.68-0.95]; P=0.009/5%). In 8 of 9 patients with >1 event, atrial tachyarrhythmia, itself a known risk factor for mortality, occurred first. There was agreement between location and extent of RV LGE at in vivo cardiovascular magnetic resonance and histologically documented focal RV fibrosis in an explanted heart. There was RV LGE progression in a different case restudied for clinical indications. Systemic RV LGE is strongly associated with adverse clinical outcome especially arrhythmia in transposition of the great arteries, thus LGE cardiovascular magnetic resonance should be incorporated in risk stratification of these patients. © 2015 American Heart Association, Inc.
Brown, Philip J; Mannava, Sandeep; Seyler, Thorsten M; Plate, Johannes F; Van Sikes, Charles; Stitzel, Joel D; Lang, Jason E
2016-10-26
Femoral head core decompression is an efficacious joint-preserving procedure for treatment of early stage avascular necrosis. However, postoperative fractures have been described which may be related to the decompression technique used. Femoral head decompressions were performed on 12 matched human cadaveric femora comparing large 8mm single bore versus multiple 3mm small drilling techniques. Ultimate failure strength of the femora was tested using a servo-hydraulic material testing system. Ultimate load to failure was compared between the different decompression techniques using two paired ANCOVA linear regression models. Prior to biomechanical testing and after the intervention, volumetric bone mineral density was determined using quantitative computed tomography to account for variation between cadaveric samples and to assess the amount of bone disruption by the core decompression. Core decompression, using the small diameter bore and multiple drilling technique, withstood significantly greater load prior to failure compared with the single large bore technique after adjustment for bone mineral density (p< 0.05). The 8mm single bore technique removed a significantly larger volume of bone compared to the 3mm multiple drilling technique (p< 0.001). However, total fracture energy was similar between the two core decompression techniques. When considering core decompression for the treatment of early stage avascular necrosis, the multiple small bore technique removed less bone volume, thereby potentially leading to higher load to failure.
O’Connor, Christopher M.; Whellan, David J.; Lee, Kerry L.; Keteyian, Steven J.; Cooper, Lawton S.; Ellis, Stephen J.; Leifer, Eric S.; Kraus, William E.; Kitzman, Dalane W.; Blumenthal, James A.; Rendall, David S.; Miller, Nancy Houston; Fleg, Jerome L.; Schulman, Kevin A.; McKelvie, Robert S.; Zannad, Faiez; Piña, Ileana L.
2010-01-01
Context Guidelines recommend that exercise training be considered for medically stable outpatients with heart failure. Previous studies have not had adequate statistical power to measure the effects of exercise training on clinical outcomes. Objective To test the efficacy and safety of exercise training among patients with heart failure. Design, Setting, and Patients Multicenter, randomized controlled trial among 2331 medically stable outpatients with heart failure and reduced ejection fraction. Participants in Heart Failure: A Controlled Trial Investigating Outcomes of Exercise Training (HF-ACTION) were randomized from April 2003 through February 2007 at 82 centers within the United States, Canada, and France; median follow-up was 30 months. Interventions Usual care plus aerobic exercise training, consisting of 36 supervised sessions followed by home-based training, or usual care alone. Main Outcome Measures Composite primary end point of all-cause mortality or hospitalization and prespecified secondary end points of all-cause mortality, cardiovascular mortality or cardiovascular hospitalization, and cardiovascular mortality or heart failure hospitalization. Results The median age was 59 years, 28% were women, and 37% had New York Heart Association class III or IV symptoms. Etiology was ischemic in 51%. Median left ventricular ejection fraction was 25%. Exercise adherence decreased from a median of 95 minutes per week during months 4 through 6 of follow-up to 74 minutes per week during months 10 through 12. A total of 759 (65%) patients in the exercise group died or were hospitalized, compared with 796 (68%) in the usual care group (hazard ratio [HR], 0.93; 95% confidence interval [CI], 0.84–1.02; P = .13). There were nonsignificant reductions in the exercise training group for mortality (189 [16%] in the exercise group vs 198 [17%] in the usual care group; HR, 0.96; 95% CI, 0.79–1.17; P = .70), cardiovascular mortality or cardiovascular hospitalization (632 [55%] in the exercise group vs 677 [58%] in the usual care group; HR, 0.92; 95% CI, 0.83–1.03; P = .14), and cardiovascular mortality or heart failure hospitalization (344 [30%] in the exercise group vs 393 [34%] in the usual care group; HR, 0.87; 95% CI, 0.75–1.00; P = .06). In prespecified supplementary analyses adjusting for highly prognostic baseline characteristics, the HRs were 0.89 (95% CI, 0.81–0.99; P = .03) for all-cause mortality or hospitalization, 0.91 (95% CI, 0.82–1.01; P = .09) for cardiovascular mortality or cardiovascular hospitalization, and 0.85 (95% CI, 0.74–0.99; P = .03) for cardiovascular mortality or heart failure hospitalization. Other adverse events were similar between the groups. Conclusions In the protocol-specified primary analysis, exercise training resulted in nonsignificant reductions in the primary end point of all-cause mortality or hospitalization and in key secondary clinical end points. After adjustment for highly prognostic predictors of the primary end point, exercise training was associated with modest significant reductions for both all-cause mortality or hospitalization and cardiovascular mortality or heart failure hospitalization. Trial Registration clinicaltrials.gov Identifier: NCT00047437 PMID:19351941
24 CFR 902.62 - Failure to submit data.
Code of Federal Regulations, 2011 CFR
2011-04-01
... receive a presumptive rating of failure for its unaudited information and shall receive zero points for... timely submission of audited information does not negate the score of zero received for the unaudited... subindicator(s) shall receive a score of zero for the relevant indicator(s) or subindicator(s) and its overall...
Spatio-temporal propagation of cascading overload failures in spatially embedded networks
NASA Astrophysics Data System (ADS)
Zhao, Jichang; Li, Daqing; Sanhedrai, Hillel; Cohen, Reuven; Havlin, Shlomo
2016-01-01
Different from the direct contact in epidemics spread, overload failures propagate through hidden functional dependencies. Many studies focused on the critical conditions and catastrophic consequences of cascading failures. However, to understand the network vulnerability and mitigate the cascading overload failures, the knowledge of how the failures propagate in time and space is essential but still missing. Here we study the spatio-temporal propagation behaviour of cascading overload failures analytically and numerically on spatially embedded networks. The cascading overload failures are found to spread radially from the centre of the initial failure with an approximately constant velocity. The propagation velocity decreases with increasing tolerance, and can be well predicted by our theoretical framework with one single correction for all the tolerance values. This propagation velocity is found similar in various model networks and real network structures. Our findings may help to predict the dynamics of cascading overload failures in realistic systems.
Spatio-temporal propagation of cascading overload failures in spatially embedded networks
Zhao, Jichang; Li, Daqing; Sanhedrai, Hillel; Cohen, Reuven; Havlin, Shlomo
2016-01-01
Different from the direct contact in epidemics spread, overload failures propagate through hidden functional dependencies. Many studies focused on the critical conditions and catastrophic consequences of cascading failures. However, to understand the network vulnerability and mitigate the cascading overload failures, the knowledge of how the failures propagate in time and space is essential but still missing. Here we study the spatio-temporal propagation behaviour of cascading overload failures analytically and numerically on spatially embedded networks. The cascading overload failures are found to spread radially from the centre of the initial failure with an approximately constant velocity. The propagation velocity decreases with increasing tolerance, and can be well predicted by our theoretical framework with one single correction for all the tolerance values. This propagation velocity is found similar in various model networks and real network structures. Our findings may help to predict the dynamics of cascading overload failures in realistic systems. PMID:26754065
NASA Astrophysics Data System (ADS)
Park, Jong Ho; Ahn, Byung Tae
2003-01-01
A failure model for electromigration based on the "failure unit model" was presented for the prediction of lifetime in metal lines.The failure unit model, which consists of failure units in parallel and series, can predict both the median time to failure (MTTF) and the deviation in the time to failure (DTTF) in Al metal lines. The model can describe them only qualitatively. In our model, both the probability function of the failure unit in single grain segments and polygrain segments are considered instead of in polygrain segments alone. Based on our model, we calculated MTTF, DTTF, and activation energy for different median grain sizes, grain size distributions, linewidths, line lengths, current densities, and temperatures. Comparisons between our results and published experimental data showed good agreements and our model could explain the previously unexplained phenomena. Our advanced failure unit model might be further applied to other electromigration characteristics of metal lines.
Reevaluating the two-representation model of numerical magnitude processing.
Jiang, Ting; Zhang, Wenfeng; Wen, Wen; Zhu, Haiting; Du, Han; Zhu, Xiangru; Gao, Xuefei; Zhang, Hongchuan; Dong, Qi; Chen, Chuansheng
2016-01-01
One debate in mathematical cognition centers on the single-representation model versus the two-representation model. Using an improved number Stroop paradigm (i.e., systematically manipulating physical size distance), in the present study we tested the predictions of the two models for number magnitude processing. The results supported the single-representation model and, more importantly, explained how a design problem (failure to manipulate physical size distance) and an analytical problem (failure to consider the interaction between congruity and task-irrelevant numerical distance) might have contributed to the evidence used to support the two-representation model. This study, therefore, can help settle the debate between the single-representation and two-representation models.
Tensile bond strength of filled and unfilled adhesives to dentin.
Braga, R R; Cesar, P F; Gonzaga, C C
2000-04-01
To determine the tensile bond strength of three filled and two unfilled adhesives applied to bovine dentin. Fragments of the labial dentin of bovine incisors were embedded in PVC cylinders with self-cure acrylic resin, and ground flat using 200 grit and 600 grit sandpaper. The following adhesive systems were tested (n=10): Prime & Bond NT, Prime & Bond NT dual cure, Prime & Bond 2.1, OptiBond Solo and Single Bond. A 3 mm-diameter bonding surface was delimited using a perforated adhesive tape. After etching with 37% phosphoric acid and adhesive application, a resin-based composite truncated cone (TPH, shade A3) was built. Tensile test was performed after 24 hrs storage in distilled water at 37 degrees C. Failure mode was accessed using a x10 magnification stereomicroscope. Weibull statistical analysis revealed significant differences in the characteristic strength between Single Bond and Prime & Bond NT dual cure, and between Single Bond and Prime & Bond 2.1. The Weibull parameter (m) was statistically similar among the five groups. Single Bond and Prime & Bond NT showed areas of dentin cohesive failure in most of the specimens. For OptiBond Solo, Prime & Bond NT dual cure and Prime & Bond 2.1 failure was predominantly adhesive.
Factors Affecting Health Related Quality of Life in Hospitalized Patients with Heart Failure
Audi, Georgia; Korologou, Aggeliki; Koutelekos, Ioannis; Karakostas, Kostas; Makrygianaki, Kleanthi
2017-01-01
This study identified factors affecting health related quality of life (HRQOL) in 300 hospitalized patients with heart failure (HF). Data were collected by the completion of a questionnaire which included patients' characteristics and the Minnesota Living with Heart Failure Questionnaire (MLHFQ). Analysis of data showed that the median of the total score of MLHFQ was 46 and the median of the physical and mental state was 22 and 6, respectively. Also, participants who were householders or had “other” professions had lower score of 17 points and therefore better quality of life compared to patients who were civil/private employees (p < 0.001 and p < 0.001, resp.). Patients not receiving anxiolytics and antidepressants had lower quality of life scores of 6 and 15.5 points, respectively, compared to patients who received (p = 0.003 and p < 0.001, resp.). Patients with no prior hospitalization had lower score of 7 points compared to those with prior hospitalization (p = 0.002), whereas patients not retired due to the disease had higher score of 7 points (p = 0.034). Similar results were observed for the physical and mental state. Improvement of HF patients' quality of life should come to the forefront of clinical practice. PMID:29201489
Repair Strength in Simulated Restorations of Methacrylate- or Silorane-Based Composite Resins.
Consani, Rafael Leonardo Xediek; Marinho, Tatiane; Bacchi, Atais; Caldas, Ricardo Armini; Feitosa, Victor Pinheiro; Pfeifer, Carmem Silvia
2016-01-01
The study verified the bond strength in simulated dental restorations of silorane- or methacrylate-based composites repaired with methacrylate-based composite. Methacrylate- (P60) or silorane-based (P90) composites were used associated with adhesive (Adper Single Bond 2). Twenty-four hemi-hourglass-shaped samples were repaired with each composite (n=12). Samples were divided according to groups: G1= P60 + Adper Single Bond 2+ P60; G2= P60 + Adper Single Bond 2 + P60 + thermocycling; G3= P90 + Adper Single Bond 2 + P60; and G4= P90 + Adper Single Bond 2 + P60 + thermocycling. G1 and G3 were submitted to tensile test 24 h after repair procedure, and G2 and G4 after submitted to 5,000 thermocycles at 5 and 55 ?#61616;C for 30 s in each bath. Tensile bond strength test was accomplished in an universal testing machine at crosshead speed of 0.5 mm/min. Data (MPa) were analyzed by two-way ANOVA and Tukey's test (5%). Sample failure pattern (adhesive, cohesive in resin or mixed) was evaluated by stereomicroscope at 30?#61655; and images were obtained in SEM. Bond strength values of methacrylate-based composite samples repaired with methacrylate-based composite (G1 and G2) were greater than for silorane-based samples (G3 and G4). Thermocycling decreased the bond strength values for both composites. All groups showed predominance of adhesive failures and no cohesive failure in composite resin was observed. In conclusion, higher bond strength values were observed in methacrylate-based resin samples and greater percentage of adhesive failures in silorane-based resin samples, both composites repaired with methacrylate-based resin.
Walking the Walk: School/University Collaboration in Teacher Education.
ERIC Educational Resources Information Center
Hayes, Curt; Camilli, Valerie; Piazza, Jenny
This paper analyzes the failure of a professional development school (PDS) initiative undertaken by a university department of education by using eight points from John P. Kotter's book "Leading Change," which describes conditions in business that prevent change and points to some necessary conditions for change to occur. The eight points and…
32 CFR 634.45 - Point system application.
Code of Federal Regulations, 2014 CFR
2014-07-01
.... Violation: Fleeing the scene (hit and run)-property damage only. Points assessed: 6 D. Violation: Driving...: 2 I. Violation: Failure to properly restrain children in a child restraint system while moving (when child is 4 years of age or younger or the weight of child does not exceed 45 pounds). Points assessed: 2...
32 CFR 634.45 - Point system application.
Code of Federal Regulations, 2012 CFR
2012-07-01
.... Violation: Fleeing the scene (hit and run)-property damage only. Points assessed: 6 D. Violation: Driving...: 2 I. Violation: Failure to properly restrain children in a child restraint system while moving (when child is 4 years of age or younger or the weight of child does not exceed 45 pounds). Points assessed: 2...
32 CFR 634.45 - Point system application.
Code of Federal Regulations, 2010 CFR
2010-07-01
.... Violation: Fleeing the scene (hit and run)-property damage only. Points assessed: 6 D. Violation: Driving...: 2 I. Violation: Failure to properly restrain children in a child restraint system while moving (when child is 4 years of age or younger or the weight of child does not exceed 45 pounds). Points assessed: 2...
32 CFR 634.45 - Point system application.
Code of Federal Regulations, 2013 CFR
2013-07-01
.... Violation: Fleeing the scene (hit and run)-property damage only. Points assessed: 6 D. Violation: Driving...: 2 I. Violation: Failure to properly restrain children in a child restraint system while moving (when child is 4 years of age or younger or the weight of child does not exceed 45 pounds). Points assessed: 2...
16 CFR 1508.11 - Requirements for cutouts.
Code of Federal Regulations, 2011 CFR
2011-01-01
... shall comply with the following test requirements: (a) Place the neck of the headform probe shown in... point of contact. The head portion of the probe shall be on the outer side of the panel. With the neck... at all points that could result in a failure), and the front of the probe pointing downwards, draw...
NASA Technical Reports Server (NTRS)
Hur-Diaz, Sun; Wirzburger, John; Smith, Dan
2008-01-01
The Hubble Space Telescope (HST) is renowned for its superb pointing accuracy of less than 10 milli-arcseconds absolute pointing error. To accomplish this, the HST relies on its complement of four reaction wheel assemblies (RWAs) for attitude control and four magnetic torquer bars (MTBs) for momentum management. As with most satellites with reaction wheel control, the fourth RWA provides for fault tolerance to maintain three-axis pointing capability should a failure occur and a wheel is lost from operations. If an additional failure is encountered, the ability to maintain three-axis pointing is jeopardized. In order to prepare for this potential situation, HST Pointing Control Subsystem (PCS) Team developed a Two Reaction Wheel Science (TRS) control mode. This mode utilizes two RWAs and four magnetic torquer bars to achieve three-axis stabilization and pointing accuracy necessary for a continued science observing program. This paper presents the design of the TRS mode and operational considerations necessary to protect the spacecraft while allowing for a substantial science program.
Ma, C Benjamin; Comerford, Lyn; Wilson, Joseph; Puttlitz, Christian M
2006-02-01
Recent studies have shown that arthroscopic rotator cuff repairs can have higher rates of failure than do open repairs. Current methods of rotator cuff repair have been limited to single-row fixation of simple and horizontal stitches, which is very different from open repairs. The objective of this study was to compare the initial cyclic loading and load-to-failure properties of double-row fixation with those of three commonly used single-row techniques. Ten paired human supraspinatus tendons were split in half, yielding four tendons per cadaver. The bone mineral content at the greater tuberosity was assessed. Four stitch configurations (two-simple, massive cuff, arthroscopic Mason-Allen, and double-row fixation) were randomized and tested on each set of tendons. Specimens were cyclically loaded between 5 and 100 N at 0.25 Hz for fifty cycles and then loaded to failure under displacement control at 1 mm/sec. Conditioning elongation, peak-to-peak elongation, ultimate tensile load, and stiffness were measured with use of a three-dimensional tracking system and compared, and the failure type (suture or anchor pull-out) was recorded. No significant differences were found among the stitches with respect to conditioning elongation. The mean peak-to-peak elongation (and standard error of the mean) was significantly lower for the massive cuff (1.1 +/- 0.1 mm) and double-row stitches (1.1 +/- 0.1 mm) than for the arthroscopic Mason-Allen stitch (1.5 +/- 0.2 mm) (p < 0.05). The ultimate tensile load was significantly higher for double-row fixation (287 +/- 24 N) than for all of the single-row fixations (p < 0.05). Additionally, the massive cuff stitch (250 +/- 21 N) was found to have a significantly higher ultimate tensile load than the two-simple (191 +/- 18 N) and arthroscopic Mason-Allen (212 +/- 21 N) stitches (p < 0.05). No significant differences in stiffness were found among the stitches. Failure mechanisms were similar for all stitches. Rotator cuff repairs in the anterior half of the greater tuberosity had a significantly lower peak-to-peak elongation and higher ultimate tensile strength than did repairs on the posterior half. In this in vitro cadaver study, double-row fixation had a significantly higher ultimate tensile load than the three types of single-row fixation stitches. Of the single-row fixations, the massive cuff stitch had cyclic and load-to-failure characteristics similar to the double-row fixation. Anterior repairs of the supraspinatus tendon had significantly stronger biomechanical behavior than posterior repairs.
Failure of wooden sandwich beam reinforced with glass/epoxy faces
DOE Office of Scientific and Technical Information (OSTI.GOV)
Papakaliatakis, G. E.; Zacharopoulos, D. A.
2015-12-31
The mechanical properties and the failure of wooden beam strengthened with two faces from glass/epoxy composite and a wooden beam without strengthening was studied. Stresses and deflections on both beams, which are imposed in three point bending loading. On the idealized geometry of the specimens with detailed nonlinear orthotropic analysis was performed with a finite elements program. The failure study of the wooden beams was performed, applying the criterion of Tsai-Hill. The shear strength of the adhesive was taken into account. All the specimens were tested with three point bending loading and the experimental results were compared to those ofmore » the theoretical approach with the finite elements analysis. Comparing the results, the advantage of strengthened wooden beam against the simple wooden beam becomes obvious. Theoretical predictions were in good agreement with experimental results.« less
Independent Orbiter Assessment (IOA): Analysis of the purge, vent and drain subsystem
NASA Technical Reports Server (NTRS)
Bynum, M. C., III
1987-01-01
The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA approach features a top-down analysis of the hardware to determine failure modes, criticality, and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. This report documents the independent analysis results corresponding to the Orbiter PV and D (Purge, Vent and Drain) Subsystem hardware. The PV and D Subsystem controls the environment of unpressurized compartments and window cavities, senses hazardous gases, and purges Orbiter/ET Disconnect. The subsystem is divided into six systems: Purge System (controls the environment of unpressurized structural compartments); Vent System (controls the pressure of unpressurized compartments); Drain System (removes water from unpressurized compartments); Hazardous Gas Detection System (HGDS) (monitors hazardous gas concentrations); Window Cavity Conditioning System (WCCS) (maintains clear windows and provides pressure control of the window cavities); and External Tank/Orbiter Disconnect Purge System (prevents cryo-pumping/icing of disconnect hardware). Each level of hardware was evaluated and analyzed for possible failure modes and effects. Criticality was assigned based upon the severity of the effect for each failure mode. Four of the sixty-two failure modes analyzed were determined as single failures which could result in the loss of crew or vehicle. A possible loss of mission could result if any of twelve single failures occurred. Two of the criticality 1/1 failures are in the Window Cavity Conditioning System (WCCS) outer window cavity, where leakage and/or restricted flow will cause failure to depressurize/repressurize the window cavity. Two criticality 1/1 failures represent leakage and/or restricted flow in the Orbiter/ET disconnect purge network which prevent cryopumping/icing of disconnect hardware. Each level of hardware was evaluated and analyzed for possible failure modes and effects. Criticality was assigned based upon the severity of the effect for each failure mode.
Improved Multi-Axial, Temperature and Time Dependent (MATT) Failure Model
NASA Technical Reports Server (NTRS)
Richardson, D. E.; Anderson, G. L.; Macon, D. J.
2002-01-01
An extensive effort has recently been completed by the Space Shuttle's Reusable Solid Rocket Motor (RSRM) nozzle program to completely characterize the effects of multi-axial loading, temperature and time on the failure characteristics of three filled epoxy adhesives (TIGA 321, EA913NA, EA946). As part of this effort, a single general failure criterion was developed that accounted for these effects simultaneously. This model was named the Multi- Axial, Temperature, and Time Dependent or MATT failure criterion. Due to the intricate nature of the failure criterion, some parameters were required to be calculated using complex equations or numerical methods. This paper documents some simple but accurate modifications to the failure criterion to allow for calculations of failure conditions without complex equations or numerical techniques.
Micromechanics Based Failure Analysis of Heterogeneous Materials
NASA Astrophysics Data System (ADS)
Sertse, Hamsasew M.
In recent decades, heterogeneous materials are extensively used in various industries such as aerospace, defense, automotive and others due to their desirable specific properties and excellent capability of accumulating damage. Despite their wide use, there are numerous challenges associated with the application of these materials. One of the main challenges is lack of accurate tools to predict the initiation, progression and final failure of these materials under various thermomechanical loading conditions. Although failure is usually treated at the macro and meso-scale level, the initiation and growth of failure is a complex phenomena across multiple scales. The objective of this work is to enable the mechanics of structure genome (MSG) and its companion code SwiftComp to analyze the initial failure (also called static failure), progressive failure, and fatigue failure of heterogeneous materials using micromechanics approach. The initial failure is evaluated at each numerical integration point using pointwise and nonlocal approach for each constituent of the heterogeneous materials. The effects of imperfect interfaces among constituents of heterogeneous materials are also investigated using a linear traction-displacement model. Moreover, the progressive and fatigue damage analyses are conducted using continuum damage mechanics (CDM) approach. The various failure criteria are also applied at a material point to analyze progressive damage in each constituent. The constitutive equation of a damaged material is formulated based on a consistent irreversible thermodynamics approach. The overall tangent modulus of uncoupled elastoplastic damage for negligible back stress effect is derived. The initiation of plasticity and damage in each constituent is evaluated at each numerical integration point using a nonlocal approach. The accumulated plastic strain and anisotropic damage evolution variables are iteratively solved using an incremental algorithm. The damage analyses are performed for both brittle failure/high cycle fatigue (HCF) for negligible plastic strain and ductile failure/low cycle fatigue (LCF) for large plastic strain. The proposed approach is incorporated in SwiftComp and used to predict the initial failure envelope, stress-strain curve for various loading conditions, and fatigue life of heterogeneous materials. The combined effects of strain hardening and progressive fatigue damage on the effective properties of heterogeneous materials are also studied. The capability of the current approach is validated using several representative examples of heterogeneous materials including binary composites, continuous fiber-reinforced composites, particle-reinforced composites, discontinuous fiber-reinforced composites, and woven composites. The predictions of MSG are also compared with the predictions obtained using various micromechanics approaches such as Generalized Methods of Cells (GMC), Mori-Tanaka (MT), and Double Inclusions (DI) and Representative Volume Element (RVE) Analysis (called as 3-dimensional finite element analysis (3D FEA) in this document). This study demonstrates that a micromechanics based failure analysis has a great potential to rigorously and more accurately analyze initiation and progression of damage in heterogeneous materials. However, this approach requires material properties specific to damage analysis, which are needed to be independently calibrated for each constituent.
Systems Reliability Framework for Surface Water Sustainability and Risk Management
NASA Astrophysics Data System (ADS)
Myers, J. R.; Yeghiazarian, L.
2016-12-01
With microbial contamination posing a serious threat to the availability of clean water across the world, it is necessary to develop a framework that evaluates the safety and sustainability of water systems in respect to non-point source fecal microbial contamination. The concept of water safety is closely related to the concept of failure in reliability theory. In water quality problems, the event of failure can be defined as the concentration of microbial contamination exceeding a certain standard for usability of water. It is pertinent in watershed management to know the likelihood of such an event of failure occurring at a particular point in space and time. Microbial fate and transport are driven by environmental processes taking place in complex, multi-component, interdependent environmental systems that are dynamic and spatially heterogeneous, which means these processes and therefore their influences upon microbial transport must be considered stochastic and variable through space and time. A physics-based stochastic model of microbial dynamics is presented that propagates uncertainty using a unique sampling method based on artificial neural networks to produce a correlation between watershed characteristics and spatial-temporal probabilistic patterns of microbial contamination. These results are used to address the question of water safety through several sustainability metrics: reliability, vulnerability, resilience and a composite sustainability index. System reliability is described uniquely though the temporal evolution of risk along watershed points or pathways. Probabilistic resilience describes how long the system is above a certain probability of failure, and the vulnerability metric describes how the temporal evolution of risk changes throughout a hierarchy of failure levels. Additionally our approach allows for the identification of contributions in microbial contamination and uncertainty from specific pathways and sources. We expect that this framework will significantly improve the efficiency and precision of sustainable watershed management strategies through providing a better understanding of how watershed characteristics and environmental parameters affect surface water quality and sustainability. With microbial contamination posing a serious threat to the availability of clean water across the world, it is necessary to develop a framework that evaluates the safety and sustainability of water systems in respect to non-point source fecal microbial contamination. The concept of water safety is closely related to the concept of failure in reliability theory. In water quality problems, the event of failure can be defined as the concentration of microbial contamination exceeding a certain standard for usability of water. It is pertinent in watershed management to know the likelihood of such an event of failure occurring at a particular point in space and time. Microbial fate and transport are driven by environmental processes taking place in complex, multi-component, interdependent environmental systems that are dynamic and spatially heterogeneous, which means these processes and therefore their influences upon microbial transport must be considered stochastic and variable through space and time. A physics-based stochastic model of microbial dynamics is presented that propagates uncertainty using a unique sampling method based on artificial neural networks to produce a correlation between watershed characteristics and spatial-temporal probabilistic patterns of microbial contamination. These results are used to address the question of water safety through several sustainability metrics: reliability, vulnerability, resilience and a composite sustainability index. System reliability is described uniquely though the temporal evolution of risk along watershed points or pathways. Probabilistic resilience describes how long the system is above a certain probability of failure, and the vulnerability metric describes how the temporal evolution of risk changes throughout a hierarchy of failure levels. Additionally our approach allows for the identification of contributions in microbial contamination and uncertainty from specific pathways and sources. We expect that this framework will significantly improve the efficiency and precision of sustainable watershed management strategies through providing a better understanding of how watershed characteristics and environmental parameters affect surface water quality and sustainability.
Effect of stress concentrations in composite structures
NASA Technical Reports Server (NTRS)
Babcock, C. D.; Waas, A. M.
1985-01-01
Composite structures have found wide use in many engineering fields and a sound understanding of their response under load is important to their utilization. An experimental program is being carried out to gain a fundamental understanding of the failure mechanics of multilayered composite structures at GALCIT. As a part of this continuing study, the performance of laminated composite plates in the presence of a stress gradient and the failure of composite structures at points of thickness discontinuity is assessed. In particular, the questions of initiation of failure and its subsequent growth to complete failure of the structure are addressed.
NASA Astrophysics Data System (ADS)
Ma, Xuejiao; Gan, Chaoqin; Deng, Shiqi; Huang, Yan
2011-11-01
A survivable wavelength division multiplexing passive optical network enabling both point-to-point service and broadcast service is presented and demonstrated. This architecture provides an automatic traffic recovery against feeder and distribution fiber link failure, respectively. In addition, it also simplifies the protection design for multiple services transmission in wavelength division multiplexing passive optical networks.
NASA Astrophysics Data System (ADS)
Zhao, Yang; Dong, Shuhong; Yu, Peishi; Zhao, Junhua
2018-06-01
The loading direction-dependent shear behavior of single-layer chiral graphene sheets at different temperatures is studied by molecular dynamics (MD) simulations. Our results show that the shear properties (such as shear stress-strain curves, buckling strains, and failure strains) of chiral graphene sheets strongly depend on the loading direction due to the structural asymmetry. The maximum values of both the critical buckling shear strain and the failure strain under positive shear deformation can be around 1.4 times higher than those under negative shear deformation. For a given chiral graphene sheet, both its failure strain and failure stress decrease with increasing temperature. In particular, the amplitude to wavelength ratio of wrinkles for different chiral graphene sheets under shear deformation using present MD simulations agrees well with that from the existing theory. These findings provide physical insights into the origins of the loading direction-dependent shear behavior of chiral graphene sheets and their potential applications in nanodevices.
Red blood cell transfusion, hyperkalemia, and heart failure in advanced chronic kidney disease.
Gill, Karminder; Fink, Jeffrey C; Gilbertson, David T; Monda, Keri L; Muntner, Paul; Lafayette, Richard A; Petersen, Jeffrey; Chertow, Glenn M; Bradbury, Brian D
2015-06-01
In recent years, the use of red blood cell (RBC) transfusion for the treatment of chronic kidney disease (CKD)-related anemia has increased. We used the OptumInsight medical claims database to study the association between receiving a transfusion and hyperkalemia and heart failure events. Persons 18-64 years of age with diagnosed stage 4 or 5 CKD (not requiring dialysis) between 2006 and 2010 were followed until their first hospitalization or emergency room visit with a diagnosis of hyperkalemia or heart failure, termination of insurance coverage, or death. We used a case-only design and conditional logistic regression to estimate rate ratios (RR) and 95% confidence intervals (CIs) describing associations between RBC transfusion and the risks of hyperkalemia or heart failure. We used single (1:1) and variable (1:m) self-control matching intervals, with adjustment for time-varying confounders. Seven thousand eight hundred twenty-nine individuals met our inclusion criteria; two-thirds were age 50 years or older; 43% were women and 51% had diabetes. Rates of hyperkalemia and heart failure were 7.9/100 person-years (95%CI: 7.3, 8.5) and 16.3/100 person-years (95%CI: 15.5, 17.2), respectively. RBC transfusion was associated with an increased risk of both hyperkalemia (single interval matched RR = 12.0, 95%CI: 1.3, 109; multiple interval matched RR = 6.1, 95%CI: 2.5, 15.1) and heart failure (single interval matched RR = 1.7, 95%CI: 0.3, 9.2; multiple interval matched RR = 3.8, 95%CI: 1.4, 10.3). In patients with advanced CKD, RBC transfusion appears to be associated with an elevated risk of hyperkalemia and heart failure; further investigation into these risks is warranted. Copyright © 2015 John Wiley & Sons, Ltd.
Ayalasomayajula, Surya; Schuehly, Uwe; Pal, Parasar; Chen, Fabian; Zhou, Wei; Sunkara, Gangadhar; Langenickel, Thomas H
2018-05-01
Sacubitril/valsartan is indicated for the treatment of heart failure and reduced ejection fraction (HFrEF). Furosemide, a loop diuretic commonly used for the treatment of HFrEF, may be coadministered with sacubitril/valsartan in clinical practice. The effect of sacubitril/valsartan on the pharmacokinetics and pharmacodynamics of furosemide was evaluated in this open label, two-period, single-sequence study in healthy subjects. All subjects (n = 28) received 40 mg oral single-dose furosemide during period 1, followed by a washout of 2 days. In period 2, sacubitril/valsartan 200 mg (97/103 mg) was administered twice daily for 5 days and a single dose of 40 mg furosemide was coadministered on day 6. Serial plasma and urine samples were collected to determine the pharmacokinetics of furosemide and sacubitril/valsartan and the pharmacodynamics of furosemide. The point estimates and the associated 90% confidence intervals for pharmacokinetic parameters were evaluated. Coadministration of furosemide with sacubitril/valsartan decreased the maximum observed plasma concentration (C max ) [estimated geometric mean ratio (90% confidence interval): 0.50 (0.44, 0.56)], area under the plasma concentration-time curve (AUC) from time 0 to infinity [0.72 (0.67, 0.77)] and 24-h urinary excretion of furosemide [0.74 (0.69, 0.79)]. When coadministered with sacubitril/valsartan, 0-4-h, 4-8-h and 0-24-h diuresis in response to furosemide was reduced by ~7%, 21% and 0.2%, respectively, while natriuresis was reduced by ~ 28.5%, 7% and 15%, respectively. Post hoc analysis of the pivotal phase III Prospective comparison of ARNI with ACEI to Determine Impact on Global Mortality and morbidity in Heart Failure trial (PARADIGM-HF) indicated that the median furosemide dose was similar at baseline and at the end of the study in the sacubitril/valsartan group. Sacubitril/valsartan reduced plasma C max and AUC and 24-h urinary excretion of furosemide, while not significantly affecting its pharmacodynamic effects in healthy subjects. © 2018 Crown copyright. British Journal of Clinical Pharmacology © 2018 British Pharmacological Society.
Flat H Redundant Frangible Joint Development
NASA Technical Reports Server (NTRS)
Brown, Chris
2016-01-01
Orion and Commercial Crew Program (CCP) Partners have chosen to use frangible joints for certain separation events. The joints currently available are zero failure tolerant and will be used in mission safety applications. The goal is to further develop a NASA designed redundant frangible joint that will lower flight risk and increase reliability. FY16 testing revealed a successful design in subscale straight test specimens that gained efficiency and supports Orion load requirements. Approach / Innovation A design constraint is that the redundant joint must fit within the current Orion architecture, without the need for additional vehicle modification. This limitation required a design that changed the orientation of the expanding tube assemblies (XTAs), by rotating them 90deg from the standard joint configuration. The change is not trivial and affects the fracture mechanism and structural load paths. To address these changes, the design incorporates cantilevered arms on the break plate. The shock transmission and expansion of the XTA applies force to these arms and creates a prying motion to push the plate walls outward to the point of structural failure at the notched section. The 2014 test design revealed that parts could slip during functioning wasting valuable energy needed to separate the structure with only a single XTA functioning. Dual XTA functioning fully separated the assembly showing a discrepancy can be backed up with redundancy. Work on other fully redundant systems outside NASA is limited to a few patents that have not been subjected to functionality testing Design changes to prevent unwanted slippage (with ICA funding in 2015) showed success with a single XTA. The main goal for FY 2016 was to send the new Flat H RFJ to WSTF where single XTA test failures occurred back in 2014. The plan was to gain efficiency in this design by separating the Flat H RFJ with thicker ligaments with dimensions baselined in 2014. Other modifications included geometry changes to better disperse loads paths and to minimize air gaps. The design additionally added more structural strength to enhance the structural limits in static loads testing. The design also implemented a smoother load line through the assembly. Results / Knowledge Gained The new Flat H RFJ successfully fractured at WSTF with thicker ligaments and lower cord size. Where failure to separate occurred earlier, there is now excessive energy available for structural separation. The new challenge to provide some structural support to prevent secondary fracturing of the break plate remains to be completed. This future work is being funded by the JSC Engineering Directorate in 2017 to elevate the TRL on curved Flat H RFJs that configure with the Orion Service Panel Separation. Additional funding from JSC Engineering will provide new design testing to avoid secondary fracturing.
Yousif, Matthew John; Bicos, James
2017-01-01
Background: The glenohumeral joint is the most commonly dislocated joint in the body. Failure rates of capsulolabral repair have been reported to be approximately 8%. Recent focus has been on restoration of the capsulolabral complex by a double-row capsulolabral repair technique in an effort to decrease redislocation rates after arthroscopic capsulolabral repair. Purpose: To present a review of the biomechanical literature comparing single- versus double-row capsulolabral repairs and discuss the previous case series of double-row fixation. Study Design: Narrative review. Methods: A simple review of the literature was performed by PubMed search. Only biomechanical studies comparing single- versus double-row capsulolabral repair were included for review. Only those case series and descriptive techniques with clinical results for double-row repair were included in the discussion. Results: Biomechanical comparisons evaluating the native footprint of the labrum demonstrated significantly superior restoration of the footprint through double-row capsulolabral repair compared with single-row repair. Biomechanical comparisons of contact pressure at the repair interface, fracture displacement in bony Bankart lesion, load to failure, and decreased external rotation (suggestive of increased load to failure) were also significantly in favor of double- versus single-row repair. Recent descriptive techniques and case series of double-row fixation have demonstrated good clinical outcomes; however, no comparative clinical studies between single- and double-row repair have assessed functional outcomes. Conclusion: The superiority of double-row capsulolabral repair versus single-row repair remains uncertain because comparative studies assessing clinical outcomes have yet to be performed. PMID:29230427
Single Parent Adoptions: An Issue of Difficulty and Import for Adoption Agencies.
ERIC Educational Resources Information Center
Rosenberg, Jeffrey
Little theoretical and empirical knowledge is available in the social work field to guide practitioners in the area of single parent adoption. In the context of demographics, the single parent family is now conventional. However there is not yet conclusive research on the success or failure of single parent households. Research has suggested that…
Improving the Patron Experience: Sterling Memorial Library's Single Service Point
ERIC Educational Resources Information Center
Sider, Laura Galas
2016-01-01
This article describes the planning process and implementation of a single service point at Yale University's Sterling Memorial Library. While much recent scholarship on single service points (SSPs) has focused on the virtues or hazards of eliminating reference desks in libraries nationwide, this essay explores the ways in which single service…
Speedy routing recovery protocol for large failure tolerance in wireless sensor networks.
Lee, Joa-Hyoung; Jung, In-Bum
2010-01-01
Wireless sensor networks are expected to play an increasingly important role in data collection in hazardous areas. However, the physical fragility of a sensor node makes reliable routing in hazardous areas a challenging problem. Because several sensor nodes in a hazardous area could be damaged simultaneously, the network should be able to recover routing after node failures over large areas. Many routing protocols take single-node failure recovery into account, but it is difficult for these protocols to recover the routing after large-scale failures. In this paper, we propose a routing protocol, referred to as ARF (Adaptive routing protocol for fast Recovery from large-scale Failure), to recover a network quickly after failures over large areas. ARF detects failures by counting the packet losses from parent nodes, and upon failure detection, it decreases the routing interval to notify the neighbor nodes of the failure. Our experimental results indicate that ARF could provide recovery from large-area failures quickly with less packets and energy consumption than previous protocols.
Thermal stress fracture of ceramic coatings
NASA Technical Reports Server (NTRS)
Andersson, C. A.
1983-01-01
Thermal stress failures of ceramic coatings are discussed in terms of fracture mechanics concepts. The effects of transient and residual stresses on single and multiple cycle failure mechanisms are considered. A specific example of a zirconia thermal barrier coating is presented and its endurance calculated using the proposed relationships.
Interruptions and Failure in Higher Education: Evidence from ISEG-UTL
ERIC Educational Resources Information Center
Chagas, Margarida; Fernandaes, Graca Leao
2011-01-01
Failure in higher education (HE) is the outcome of multiple time-dependent determinants. Interruptions in students' individual school trajectories are one of them, and that is why research on this topic has been attracting much attention these days. From an individual point of view, it is expected that interruptions in school trajectory, whatever…
Decentralized Orchestration of Composite Ogc Web Processing Services in the Cloud
NASA Astrophysics Data System (ADS)
Xiao, F.; Shea, G. Y. K.; Cao, J.
2016-09-01
Current web-based GIS or RS applications generally rely on centralized structure, which has inherent drawbacks such as single points of failure, network congestion, and data inconsistency, etc. The inherent disadvantages of traditional GISs need to be solved for new applications on Internet or Web. Decentralized orchestration offers performance improvements in terms of increased throughput and scalability and lower response time. This paper investigates build time and runtime issues related to decentralized orchestration of composite geospatial processing services based on OGC WPS standard specification. A case study of dust storm detection was demonstrated to evaluate the proposed method and the experimental results indicate that the method proposed in this study is effective for its ability to produce the high quality solution at a low cost of communications for geospatial processing service composition problem.
Probing Dynamic Processes in Explosives and Propellants - Science Issues
NASA Astrophysics Data System (ADS)
Moore, David
2017-06-01
Recent experiments on advanced light sources have started to unravel some of the micromechanical behavior of single crystal energetic materials, including void collapse under shock loading and inter-granular failure. These examples just scratch the surface of many extant explosives science issues, which could be elucidated with advanced XFEL-type resources. These include such diverse questions as: How do powders actually compact and what are the spatially and temporally resolved temperature and flow fields generated (especially two-phase flows)? Are there polymorphic effects (if so, how are they spatially distributed)? What are the strain fields during compaction? What happens near surfaces, especially for composite explosives? How is mechanics coupled to chemistry? What are hot spots really? I will provide some history behind these and other questions and point towards how future experiments might be designed to provide some answers.
Auditory frequency generalization in the goldfish (Carassius auratus)1
Fay, Richard R.
1970-01-01
Auditory frequency generalization in the goldfish was studied at five points within the best hearing range through the use of classical respiratory conditioning. Each experimental group received single-stimulus conditioning sessions at one of five stimulus frequencies (100, 200, 400, 800, and 1600 Hz), and were subsequently tested for generalization at eight neighboring frequencies. All stimuli were presented 30 db above absolute threshold. Significant generalization decrements were found for all subjects. For the subjects conditioned in the range between 100 and 800 Hz, a nearly complete failure to generalize was found at one octave above and below the training frequency. The subjects conditioned at 1600 Hz produced relatively more flat gradients between 900 and 2000 Hz. The widths of the generalization gradients, expressed in Hz, increased as a power function of frequency with a slope greater than one. PMID:16811481
Monolithic Flexure Pre-Stressed Ultrasonic Horns
NASA Technical Reports Server (NTRS)
Sherrit, Stewart (Inventor); Badescu, Mircea (Inventor); Allen, Phillip Grant (Inventor); Bao, Xiaoqi (Inventor); Bar-Cohen, Yoseph (Inventor)
2016-01-01
A monolithic ultrasonic horn where the horn, backing, and pre-stress structures are combined in a single monolithic piece is disclosed. Pre-stress is applied by external flexure structures. The provision of the external flexures has numerous advantages including the elimination of the need for a pre-stress bolt. The removal of the pre-stress bolt eliminates potential internal electric discharge points in the actuator. In addition, it reduces the chances of mechanical failure in the actuator stacks that result from the free surface in the hole of conventional ring stacks. In addition, the removal of the stress bolt and the corresponding reduction in the overall number of parts reduces the overall complexity of the resulting ultrasonic horn actuator and simplifies the ease of the design, fabrication and integration of the actuator of the present invention into other structures.
Monolithic Flexure Pre-Stressed Ultrasonic Horns
NASA Technical Reports Server (NTRS)
Bao, Xiaoqi (Inventor); Bar-Cohen, Yoseph (Inventor); Badescu, Mircea (Inventor); Allen, Phillip Grant (Inventor); Sherrit, Stewart (Inventor)
2015-01-01
A monolithic ultrasonic horn where the horn, backing, and pre-stress structures are combined in a single monolithic piece is disclosed. Pre-stress is applied by external flexure structures. The provision of the external flexures has numerous advantages including the elimination of the need for a pre-stress bolt. The removal of the pre-stress bolt eliminates potential internal electric discharge points in the actuator. In addition, it reduces the chances of mechanical failure in the actuator stacks that result from the free surface in the hole of conventional ring stacks. In addition, the removal of the stress bolt and the corresponding reduction in the overall number of parts reduces the overall complexity of the resulting ultrasonic horn actuator and simplifies the ease of the design, fabrication and integration of the actuator of the present invention into other structures.
NASA Astrophysics Data System (ADS)
Heine, Frank; Schwander, Thomas; Lange, Robert; Smutny, Berry
2006-04-01
Tesat-Spacecom has developed a series of fiber coupled single frequency lasers for space applications ranging from onboard metrology for space borne FTIR spectrometers to step tunable seed lasers for LIDAR applications. The cw-seed laser developed for the ESA AEOLUS Mission shows a 3* 10 -11 Allen variance from 1 sec time intervals up to 1000 sec. Q-switched lasers with stable beam pointing under space environments are another field of development. One important aspect of a space borne laser system is a reliable fiber coupled laser diode pump source around 808nm. A dedicated development concerning chip design and packaging yielded in a 5*10 6h MTTF (mean time to failure) for the broad area emitters. Qualification and performance test results for the different laser assemblies will be presented and their application in the different space programs.
16 CFR 1509.13 - Requirements for cutouts.
Code of Federal Regulations, 2011 CFR
2011-01-01
... cribs shall comply with the following test requirements: (a) Place the neck of the headform probe shown... the point of contact. The head portion of the probe shall be on the outer side of the panel. With the... may test at all points that could result in a failure), and the front of the probe pointing downwards...
The Role of Crack Formation in Chevron-Notched Four-Point Bend Specimens
NASA Technical Reports Server (NTRS)
Calomino, Anthony M.; Ghosn, Louis J.
1994-01-01
The failure sequence following crack formation in a chevron-notched four-point bend 1 specimen is examined in a parametric study using the Bluhm slice synthesis model. Premature failure resulting from crack formation forces which exceed those required to propagate a crack beyond alpha (min) is examined together with the critical crack length and critical crack front length. An energy based approach is used to establish factors which forecast the tendency of such premature failure due to crack formation for any selected chevron-notched geometry. A comparative study reveals that, for constant values of alpha (1) and alpha (0), the dimensionless beam compliance and stress intensity factor are essentially independent of specimen width and thickness. The chevron tip position, alpha (0) has its primary effect on the force required to initiate a sharp crack. Small values for alpha (0) maximize the stable region length, however, the premature failure tendency is also high for smaller alpha (0) values. Improvements in premature failure resistance can be realized for larger values of alpha (0) with only a minor reduction in the stable region length. The stable region length is also maximized for larger chevron based positions, alpha (1) but the chance for premature failure is also raised. Smaller base positions improve the premature failure resistance with only minor decreases in the stable region length. Chevron geometries having a good balance of premature failure resistance, stable region length, and crack front length are 0.20 less than or equal to alpha (0) is less than or equal to 0.30 and 0.70 is less than or equal to alpha (1) is less than or equal to 0.80.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schubert, L; Westerly, D; Vinogradskiy, Y
Purpose: Collisions between treatment equipment and patients are potentially catastrophic. Modern technology now commonly involves automated remote motion during imaging and treatment, yet a systematic assessment to identify and mitigate collision risks has yet to be performed. Failure modes and effects analysis (FMEA) is a method of risk assessment that has been increasingly used in healthcare, yet can be resource intensive. This work presents an efficient approach to FMEA to identify collision risks and implement practical interventions within a modern radiation therapy department. Methods: Potential collisions (e.g. failure modes) were assessed for all treatment and simulation rooms by teams consistingmore » of physicists, therapists, and radiation oncologists. Failure modes were grouped into classes according to similar characteristics. A single group meeting was held to identify implementable interventions for the highest priority classes of failure modes. Results: A total of 60 unique failure modes were identified by 6 different teams of physicists, therapists, and radiation oncologists. Failure modes were grouped into four main classes: specific patient setups, automated equipment motion, manual equipment motion, and actions in QA or service mode. Two of these classes, unusual patient setups and automated machine motion, were identified as being high priority in terms severity of consequence and addressability by interventions. The two highest risk classes consisted of 33 failure modes (55% of the total). In a single one hour group meeting, 6 interventions were identified. Those interventions addressed 100% of the high risk classes of failure modes (55% of all failure modes identified). Conclusion: A class-based approach to FMEA was developed to efficiently identify collision risks and implement interventions in a modern radiation oncology department. Failure modes and interventions will be listed, and a comparison of this approach against traditional FMEA methods will be presented.« less
SU-E-T-495: Neutron Induced Electronics Failure Rate Analysis for a Single Room Proton Accelerator
DOE Office of Scientific and Technical Information (OSTI.GOV)
Knutson, N; DeWees, T; Klein, E
2014-06-01
Purpose: To determine the failure rate as a function of neutron dose of the range modulator's servo motor controller system (SMCS) while shielded with Borated Polyethylene (BPE) and unshielded in a single room proton accelerator. Methods: Two experimental setups were constructed using two servo motor controllers and two motors. Each SMCS was then placed 30 cm from the end of the plugged proton accelerator applicator. The motor was then turned on and observed from outside of the vault while being irradiated to known neutron doses determined from bubble detector measurements. Anytime the motor deviated from the programmed motion a failuremore » was recorded along with the delivered dose. The experiment was repeated using 9 cm of BPE shielding surrounding the SMCS. Results: Ten SMCS failures were recorded in each experiment. The dose per monitor unit for the unshielded SMCS was 0.0211 mSv/MU and 0.0144 mSv/MU for the shielded SMCS. The mean dose to produce a failure for the unshielded SMCS was 63.5 ± 58.3 mSv versus 17.0 ±12.2 mSv for the shielded. The mean number of MUs between failures were 2297 ± 1891 MU for the unshielded SMCS and 2122 ± 1523 MU for the shielded. A Wilcoxon Signed Ranked test showed the dose between failures were significantly different (P value = 0.044) while the number of MUs between failures were not (P value = 1.000). Statistical analysis determined a SMCS neutron dose of 5.3 mSv produces a 5% chance of failure. Depending on the workload and location of the SMCS, this failure rate could impede clinical workflow. Conclusion: BPE shielding was shown to not reduce the average failure of the SMCS and relocation of the system outside of the accelerator vault was required to lower the failure rate enough to avoid impeding clinical work flow.« less
NASA Technical Reports Server (NTRS)
Moncada, Albert M.; Chattopadhyay, Aditi; Bednarcyk, Brett A.; Arnold, Steven M.
2008-01-01
Predicting failure in a composite can be done with ply level mechanisms and/or micro level mechanisms. This paper uses the Generalized Method of Cells and High-Fidelity Generalized Method of Cells micromechanics theories, coupled with classical lamination theory, as implemented within NASA's Micromechanics Analysis Code with Generalized Method of Cells. The code is able to implement different failure theories on the level of both the fiber and the matrix constituents within a laminate. A comparison is made among maximum stress, maximum strain, Tsai-Hill, and Tsai-Wu failure theories. To verify the failure theories the Worldwide Failure Exercise (WWFE) experiments have been used. The WWFE is a comprehensive study that covers a wide range of polymer matrix composite laminates. The numerical results indicate good correlation with the experimental results for most of the composite layups, but also point to the need for more accurate resin damage progression models.
Single-Event Effects in Silicon and Silicon Carbide Power Devices
NASA Technical Reports Server (NTRS)
Lauenstein, Jean-Marie; Casey, Megan C.; LaBel, Kenneth A.; Topper, Alyson D.; Wilcox, Edward P.; Kim, Hak; Phan, Anthony M.
2014-01-01
NASA Electronics Parts and Packaging program-funded activities over the past year on single-event effects in silicon and silicon carbide power devices are presented, with focus on SiC device failure signatures.
The Need to Develop a National Health Strategy - A Report on the Industry
2005-03-18
failures prevent the health care industry from reaching its best potential efficiency in terms of resource allocation. This dichotomy clearly illustrates...been as high as “greater than 27.5” (two-and-a-half points higher than the federal standard), 1,400 service members were discharged for failure to meet...bring science and sanity to the chaos of weight loss by adopting the World Health Organization’s view that obesity is not a failure of willpower but
NASA Astrophysics Data System (ADS)
Kraus, E. I.; Shabalin, I. I.; Shabalin, T. I.
2018-04-01
The main points of development of numerical tools for simulation of deformation and failure of complex technical objects under nonstationary conditions of extreme loading are presented. The possibility of extending the dynamic method for construction of difference grids to the 3D case is shown. A 3D realization of discrete-continuum approach to the deformation and failure of complex technical objects is carried out. The efficiency of the existing software package for 3D modelling is shown.
1987-08-26
example, expert systems research would benefit examples are the Acute Renal Failure [15] system, the if it could attract statisticians to assist in...research projects including the Acute Renal Failure [15] system, the 6. EXPLAINING COMPLEX REASONING INTERNIST-] [22] system for diagnosis within the...the MEDAS and Acute Renal Failure systems. task at any point in reasoning about a case is constrained to Entropy-discriminate makes use of a measure
Homer, Michael V.; Charo, Lindsey M.; Natarajan, Loki; Haunschild, Carolyn; Chung, Karine; Mao, Jun J.; DeMichele, Angela M.; Su, H. Irene
2016-01-01
Objective To determine if inter-individual genetic variation in single nucleotide polymorphisms related to age at natural menopause are associated with risk of ovarian failure in breast cancer survivors. Methods A prospective cohort of 169 premenopausal breast cancer survivors recruited at diagnosis with Stages 0 to III disease were followed longitudinally for menstrual pattern via self-reported daily menstrual diaries. Participants were genotyped for 13 single nucleotide polymorphisms (SNPs) previously found to be associated with age at natural menopause: EXO1, TLK1, HELQ, UIMC1, PRIM1, POLG, TMEM224, BRSK1, and MCM8. A risk variable summed the total number of risk alleles in each participant. The association between individual genotypes, as well as the risk variable, and time to ovarian failure (> 12 months of amenorrhea) was tested using time-to-event methods. Results Median age at enrollment was 40.5 years old (range 20.6–46.1). The majority of participants were white (69%) and underwent chemotherapy (76%). Thirty-eight participants (22%) experienced ovarian failure. None of the candidate SNPs or the summary risk variable were significantly associated with time to ovarian failure. Sensitivity analysis restricted to whites or only to participants receiving chemotherapy yielded similar findings. Older age, chemotherapy exposure and lower BMI were related to shorter time to ovarian failure. Conclusions Thirteen previously identified genetic variants associated with time to natural menopause were not related to timing of ovarian failure in breast cancer survivors. PMID:28118297
Grégoire, David; Verdon, Laura; Lefort, Vincent; Grassl, Peter; Saliba, Jacqueline; Regoin, Jean-Pierre; Loukili, Ahmed; Pijaudier-Cabot, Gilles
2015-10-25
The purpose of this paper is to analyse the development and the evolution of the fracture process zone during fracture and damage in quasi-brittle materials. A model taking into account the material details at the mesoscale is used to describe the failure process at the scale of the heterogeneities. This model is used to compute histograms of the relative distances between damaged points. These numerical results are compared with experimental data, where the damage evolution is monitored using acoustic emissions. Histograms of the relative distances between damage events in the numerical calculations and acoustic events in the experiments exhibit good agreement. It is shown that the mesoscale model provides relevant information from the point of view of both global responses and the local failure process. © 2015 The Authors. International Journal for Numerical and Analytical Methods in Geomechanics published by John Wiley & Sons Ltd.
NASA Technical Reports Server (NTRS)
Fasanella, Edwin L.; Sotiris, Kellas
2006-01-01
Static 3-point bend tests of Reinforced Carbon-Carbon (RCC) were conducted to failure to provide data for additional validation of an LS-DYNA RCC model suitable for predicting the threshold of impact damage to shuttle orbiter wing leading edges. LS-DYNA predictions correlated well with the average RCC failure load, and were good in matching the load vs. deflection. However, correlating the detectable damage using NDE methods with the cumulative damage parameter in LS-DYNA material model 58 was not readily achievable. The difficulty of finding internal RCC damage with NDE and the high sensitivity of the mat58 damage parameter to the load near failure made the task very challenging. In addition, damage mechanisms for RCC due to dynamic impact of debris such as foam and ice and damage mechanisms due to a static loading were, as expected, not equivalent.
Di Bella, Claudia; Dozza, Barbara; Frisoni, Tommaso; Cevolani, Luca; Donati, Davide
2010-11-01
Unicameral bone cysts are benign lesions that usually spontaneously regress with skeletal maturity; however, the high risk of pathologic fractures often justifies treatment that could reinforce a weakened bone cortex. Various treatments have been proposed but there is no consensus regarding the best procedure. We compared the healing rates and failures of two methods of cure based on multiple injections of corticosteroid or a single injection of demineralized bone matrix (DBM) in association with bone marrow concentrate (BMC). We retrospectively reviewed 184 patients who had one of the two treatments for unicameral bone cysts with cortical erosion. Clinical records were reviewed for treatment failures and radiographs for healing in all patients. The minimum followup was 12 months for the Steroids Group (mean, 48 months; range, 12-120 months) and 12 months for the DBM + BMC Group (mean, 20 months; range, 12-28 months). After one treatment we observed a lower healing rate of cysts treated with multiple injections of steroids compared with the healing after the first injection of DBM + BMC (21% versus 58%, respectively). At last followup, 38% healed with steroids and 71% with DBM + BMC. The rate of failure after one steroid injection was higher than after a single injection of BDM + BMC (63% versus 24%, respectively). We observed no difference in fracture rates after treatment between the two groups. A single injection of DBM added with autologous bone marrow concentrate appears to provide a higher healing rate with a lower number of failures compared with a single injection of steroids.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bianchi, Marzia; Rizza, Teresa; Verrigni, Daniela
2011-11-18
Highlights: Black-Right-Pointing-Pointer Expanded array of mtDNA deletions. Black-Right-Pointing-Pointer Pearson syndrome with prominent hepatopathy associated with single mtDNA deletions. Black-Right-Pointing-Pointer Detection of deletions in fibroblasts and blood avoids muscle and liver biopsy. Black-Right-Pointing-Pointer Look for mtDNA deletions before to study nuclear genes related to mtDNA depletion. -- Abstract: Hepatic involvement in mitochondrial cytopathies rarely manifests in adulthood, but is a common feature in children. Multiple OXPHOS enzyme defects in children with liver involvement are often associated with dramatically reduced amounts of mtDNA. We investigated two novel large scale deletions in two infants with a multisystem disorder and prominent hepatopathy. Amount ofmore » mtDNA deletions and protein content were measured in different post-mortem tissues. The highest levels of deleted mtDNA were in liver, kidney, pancreas of both patients. Moreover, mtDNA deletions were detected in cultured skin fibroblasts in both patients and in blood of one during life. Biochemical analysis showed impairment of mainly complex I enzyme activity. Patients manifesting multisystem disorders in childhood may harbour rare mtDNA deletions in multiple tissues. For these patients, less invasive blood specimens or cultured fibroblasts can be used for molecular diagnosis. Our data further expand the array of deletions in the mitochondrial genomes in association with liver failure. Thus analysis of mtDNA should be considered in the diagnosis of childhood-onset hepatopathies.« less
neutron-Induced Failures in semiconductor Devices
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wender, Stephen Arthur
2017-03-13
Single Event Effects are a very significant failure mode in modern semiconductor devices that may limit their reliability. Accelerated testing is important for semiconductor industry. Considerable more work is needed in this field to mitigate the problem. Mitigation of this problem will probably come from Physicists and Electrical Engineers working together
The Pardoning of Richard Nixon: A Failure in Motivational Strategy.
ERIC Educational Resources Information Center
Klumpp, James F.; Lukehart, Jeffrey K.
1978-01-01
Discusses the failure of Gerald Ford's speech pardoning Richard Nixon and the relationship between moral and legal themes. The speech failed because Ford did not effectively combine these themes into a single compatible perspective from which his pardon became the appropriate response to the situation. (JMF)
Study on acoustic-electric-heat effect of coal and rock failure processes under uniaxial compression
NASA Astrophysics Data System (ADS)
Li, Zhong-Hui; Lou, Quan; Wang, En-Yuan; Liu, Shuai-Jie; Niu, Yue
2018-02-01
In recent years, coal and rock dynamic disasters are becoming more and more severe, which seriously threatens the safety of coal mining. It is necessary to carry out an depth study on the various geophysical precursor information in the process of coal and rock failure. In this paper, with the established acoustic-electric-heat multi-parameter experimental system of coal and rock, the acoustic emission (AE), surface potential and thermal infrared radiation (TIR) signals were tested and analyzed in the failure processes of coal and rock under the uniaxial compression. The results show that: (1) AE, surface potential and TIR have different response characteristics to the failure process of the sample. AE and surface potential signals have the obvious responses to the occurrence, extension and coalescence of cracks. The abnormal TIR signals occur at the peak and valley points of the TIR temperature curve, and are coincident with the abnormities of AE and surface potential to a certain extent. (2) The damage precursor points and the critical precursor points were defined to analyze the precursor characteristics reflected by AE, surface potential and TIR signals, and the different signals have the different precursor characteristics. (3) The increment of the maximum TIR temperature after the main rupture of the sample is significantly higher than that of the average TIR temperature. Compared with the maximum TIR temperature, the average TIR temperature has significant hysteresis in reaching the first peak value after the main rapture. (4) The TIR temperature contour plots at different times well show the evolution process of the surface temperature field of the sample, and indicate that the sample failure originates from the local destruction.
Beckers, Paul J; Possemiers, Nadine M; Van Craenenbroeck, Emeline M; Van Berendoncks, An M; Wuyts, Kurt; Vrints, Christiaan J; Conraads, Viviane M
2012-02-01
Exercise training efficiently improves peak oxygen uptake (V˙O2peak) in patients with chronic heart failure. To optimize training-derived benefit, higher exercise intensities are being explored. The correct identification of anaerobic threshold is important to allow safe and effective exercise prescription. During 48 cardiopulmonary exercise tests obtained in patients with chronic heart failure (59.6 ± 11 yrs; left ventricular ejection fraction, 27.9% ± 9%), ventilatory gas analysis findings and lactate measurements were collected. Three technicians independently determined the respiratory compensation point (RCP), the heart rate turning point (HRTP) and the second lactate turning point (LTP2). Thereafter, exercise intensity (target heart rate and workload) was calculated and compared between the three methods applied. Patients had significantly reduced maximal exercise capacity (68% ± 21% of predicted V˙O2peak) and chronotropic incompetence (74% ± 7% of predicted peak heart rate). Heart rate, workload, and V˙O2 at HRTP and at RCP were not different, but at LTP2, these parameters were significantly (P < 0.0001) higher. Mean target heart rate and target workload calculated using the LTP2 were 5% and 12% higher compared with those calculated using HRTP and RCP, respectively. The calculation of target heart rate based on LTP2 was 5% and 10% higher in 12 of 48 (25%) and 6 of 48 (12.5%) patients, respectively, compared with the other two methods. In patients with chronic heart failure, RCP and HRTP, determined during cardiopulmonary exercise tests, precede the occurrence of LTP2. Target heart rates and workloads used to prescribe tailored exercise training in patients with chronic heart failure based on LTP2 are significantly higher than those derived from HRTP and RCP.
Efird, Chad; Traub, Shaun; Baldini, Todd; Rioux-Forker, Dana; Spalazzi, Jeffrey P; Davisson, Twana; Hawkins, Monica; McCarty, Eric
2013-08-01
The purpose of this study was to compare the gap formation during cyclic loading, maximum repair strength, and failure mode of single-row full-thickness supraspinatus repairs performed using 2 knotless suture anchors with differing internal suture-retention mechanisms in a human cadaver model. Nine matched pairs of cadaver shoulders were used. Full-thickness tears were induced by detaching the supraspinatus tendon from the greater tuberosity. Single-row repairs were performed with either type I (Opus Magnum PI; ArthroCare, Austin, Texas) or type II (ReelX STT; Stryker, Mahwah, New Jersey) knotless suture anchors. The repaired tendon was cycled from 10 to 90 N for 500 cycles, followed by load to failure. Gap formation was measured at 5, 100, 200, 300, 400, and 500 cycles with a video digitizing system. Anchor type or location (anterior or posterior) had no effect on gap formation during cyclic loading regardless of position (anterior, P=.385; posterior, P=.389). Maximum load to failure was significantly greater (P=.018) for repairs performed with type II anchors (288±62 N) compared with type I anchors (179±39 N). Primary failure modes were anchor pullout and tendon tearing for type II anchors and suture slippage through the anchor for type I anchors. The internal ratcheting suture-retention mechanism of type II anchors may have helped this anchor outperform the suture-cinching mechanism of type I anchors by supporting significantly higher loads before failure and minimizing suture slippage, potentially leading to stronger repairs clinically. Copyright 2013, SLACK Incorporated.
Tarui, Suguru; Ishigami, Shuta; Ousaka, Daiki; Kasahara, Shingo; Ohtsuki, Shinichi; Sano, Shunji; Oh, Hidemasa
2015-11-01
Our aim was to assess midterm safety and clinical outcomes of intracoronary infusion of cardiosphere-derived cells (CDCs) after staged palliation in patients with hypoplastic left heart syndrome (HLHS). In this prospective, controlled study, 14 consecutive patients with HLHS who were undergoing 2- or 3-stage surgical palliations were assigned to receive intracoronary CDC infusion 1 month after cardiac surgery (n = 7), followed by 7 patients allocated to a control group with standard care alone. The primary end point was to assess procedural feasibility and safety; the secondary end point was to evaluate cardiac function and heart failure status through 36-month follow-up. No complications, including tumor formation, were reported within 36 months after CDC infusion. Echocardiography showed significantly greater improvement in right ventricular ejection fraction (RVEF) in infants receiving CDCs than in controls at 36 months (+8.0% ± 4.7% vs +2.2% ± 4.3%; P = .03). These cardiac function improvements resulted in reduced brain natriuretic peptide levels (P = .04), lower incidence of unplanned catheter interventions (P = .04), and higher weight-for-age z score (P = .02) at 36 months relative to controls. As independent predictors of treatment responsiveness, absolute changes in RVEF at 36 months were negatively correlated with age, weight-for-age z score, and RVEF at CDC infusion. Intracoronary CDC infusion after staged procedure in patients with HLHS is safe and improves RVEF, which persists during 36-month follow-up. This therapeutic strategy may enhance somatic growth and reduce incidence of heart failure. Copyright © 2015 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.
Grelpois, Gérard; Sabbagh, Charles; Cosse, Cyril; Robert, Brice; Chapuis-Roux, Emilie; Ntouba, Alexandre; Lion, Thierry; Regimbeau, Jean-Marc
2016-11-01
Day case surgery (DCS) for uncomplicated acute appendicitis (NCAA) is evaluated. The objective of this prospective, single-center, descriptive, nonrandomized, intention-to-treat cohort study was to assess the feasibility of DCS for NCAA with a critical analysis of the reasons for exclusion and treatment failures and a focus on patients discharged to home and admitted for DCS on the following day. From April 2013 to December 2015, NCAA patients meeting the inclusion criteria were included in the study. The primary end point was the success rate for DCS (length of stay less than 12 hours) in the intention-to-treat population (all NCAA) and in the per-protocol population (no pre- or perioperative exclusion criteria). The secondary end points were morbidity, DCS quality criteria, predictive factors for successful DCS, patient satisfaction, quality of life, and reasons for pre- or perioperative exclusion. A subgroup of patients discharged to home the day before operation was also analyzed. A total of 240 patients were included. The success rate of DCS was 31.5% in the intention-to-treat population and 91.5% in the per-protocol population. The rates of unplanned consultations, hospitalization, and reoperation were 13%, 4%, and 1%, respectively. An analysis of the reasons for DCS exclusion showed that 73% could have been modified. For the 68 patients discharged to home on the day before operation, the DCS success rate was 91%. Day case surgery is feasible in NCAA. A critical analysis of the reasons for exclusion from DCS showed that it should be possible to dramatically increase the eligible population. Copyright © 2016 American College of Surgeons. Published by Elsevier Inc. All rights reserved.
Understanding and reducing the risk of supply chain disruptions.
Clark, Graham
2012-01-01
Natural disasters can wreck havoc on business operations. When civil unrest swept the UK in August 2011, the effect on business was stark, losing the retail sector £300m in unexpected costs and lost revenues. On the other side of the world, the natural disaster that hit Japan in early 2011 is estimated to have run up costs in the region of £189bn in repairs. Beyond this, the earthquake and its aftermath shattered supply chains, with technology companies expecting delays of up to six months before business could resume fully. It is impossible to predict incidents like these, but businesses can help mitigate disruption in the supply chain by undertaking business continuity management (BCM). A flexible supply chain is essential when it comes to BCM - whether it means being able to cope with altering transport routes at short notice, or finding or replacing a supplier at the last minute. Understanding the supply chain is critical when responding to major impacts that affect supply chains in multiple points - like IT system failures and country-wide fuel strikes. Businesses should carry out detailed business impact assessments and risk assessments right across the end-to-end supply chain and not just at key single points of failure. It is an intensive process that needs dedicated resources and ownership at the highest level. Recognising this, DHL has designed a 10-step process, which it has implemented across its global supply chain business. This paper provides an overview of what a supply chain really looks like, what can cause disruptions and how far up/down the supply chain companies need to go with their BCM planning.
Pharmacokinetics of brotizolam in renal failure
Evers, J.; Renner, E.; Bechtel, W. D.
1983-01-01
1 Kinetics of brotizolam (0.25 mg) were studied in patients with different degrees of renal failure after single and repeated oral ingestion. Serum levels were analysed by radio-immunoassay. 2 Patients were divided into three groups according to their renal function, i.e. creatinine clearance values of 45-80, 15-45, or less than 15 ml/min. 3 The mean elimination half-life was 6.9-8.15 h, with a considerable variation of the peak concentration and elimination half-life in slight to moderate renal failure. There was no delay in elimination in severe renal failure and there was no drug accumulation. 4 No dose adjustment is necessary for brotizolam in renal failure. PMID:6661376
Modeling Progressive Failure of Bonded Joints Using a Single Joint Finite Element
NASA Technical Reports Server (NTRS)
Stapleton, Scott E.; Waas, Anthony M.; Bednarcyk, Brett A.
2010-01-01
Enhanced finite elements are elements with an embedded analytical solution which can capture detailed local fields, enabling more efficient, mesh-independent finite element analysis. In the present study, an enhanced finite element is applied to generate a general framework capable of modeling an array of joint types. The joint field equations are derived using the principle of minimum potential energy, and the resulting solutions for the displacement fields are used to generate shape functions and a stiffness matrix for a single joint finite element. This single finite element thus captures the detailed stress and strain fields within the bonded joint, but it can function within a broader structural finite element model. The costs associated with a fine mesh of the joint can thus be avoided while still obtaining a detailed solution for the joint. Additionally, the capability to model non-linear adhesive constitutive behavior has been included within the method, and progressive failure of the adhesive can be modeled by using a strain-based failure criteria and re-sizing the joint as the adhesive fails. Results of the model compare favorably with experimental and finite element results.
Malonza, I M; Tyndall, M W; Ndinya-Achola, J O; Maclean, I; Omar, S; MacDonald, K S; Perriens, J; Orle, K; Plummer, F A; Ronald, A R; Moses, S
1999-12-01
A randomized, double-blind, placebo-controlled clinical trial was conducted in Nairobi, Kenya, to compare single-dose ciprofloxacin with a 7-day course of erythromycin for the treatment of chancroid. In all, 208 men and 37 women presenting with genital ulcers clinically compatible with chancroid were enrolled. Ulcer etiology was determined using culture techniques for chancroid, serology for syphilis, and a multiplex polymerase chain reaction for chancroid, syphilis, and herpes simplex virus (HSV). Ulcer etiology was 31% unmixed chancroid, 23% unmixed syphilis, 16% unmixed HSV, 15% mixed etiology, and 15% unknown. For 111 participants with chancroid, cure rates were 92% with ciprofloxacin and 91% with erythromycin. For all study participants, the treatment failure rate was 15%, mostly related to ulcer etiologies of HSV infection or syphilis, and treatment failure was 3 times more frequent in human immunodeficiency virus-infected subjects than in others, mostly owing to HSV infection. Ciprofloxacin is an effective single-dose treatment for chancroid, but current recommendations for empiric therapy of genital ulcers may result in high treatment failure due to HSV infection.
Porosity Evolution in a Creeping Single Crystal (Preprint)
2012-08-01
1] indicated that the growth of initially present processing induced voids in a nickel based single crystal superalloy played a significant role in...processing induced voids in a nickel based single crystal superalloy played a significant role in limiting creep life. Also, creep tests on single...experimental observations of creep deformation and failure of a nickel based single crystal superalloy, [1, 2]. Metallographic observations have shown that Ni
Gajendran, Varun K; Szabo, Robert M; Myo, George K; Curtiss, Shane B
2009-12-01
Open or unstable metacarpal fractures frequently require open reduction and internal fixation. Locking plate technology has improved fixation of unstable fractures in certain settings. In this study, we hypothesized that there would be a difference in strength of fixation using double-row locking plates compared with single- and double-row non-locking plates in comminuted metacarpal fractures. We tested our hypothesis in a gap metacarpal fracture model simulating comminution using fourth-generation, biomechanical testing-grade composite sawbones. The metacarpals were divided into 6 groups of 15 bones each. Groups 1 and 4 were plated with a standard 6-hole, 2.3-mm plate in AO fashion. Groups 2 and 5 were plated with a 6-hole double-row 3-dimensional non-locking plate with bicortical screws aimed for convergence. Groups 3 and 6 were plated with a 6-hole double-row 3-dimensional locking plate with unicortical screws. The plated metacarpals were then tested to failure against cantilever apex dorsal bending (groups 1-3) and torsion (groups 4-6). The loads to failure in groups 1 to 3 were 198 +/- 18, 223 +/- 29, and 203 +/- 19 N, respectively. The torques to failure in groups 4 to 6 were 2,033 +/- 155, 3,190 +/- 235, and 3,161 +/- 268 N mm, respectively. Group 2 had the highest load to failure, whereas groups 5 and 6 shared the highest torques to failure (p < .05). Locking and non-locking double-row plates had equivalent bending and torsional stiffness, significantly higher than observed for the single-row non-locking plate. No other statistical differences were noted between groups. When subjected to the physiologically relevant forces of apex dorsal bending and torsion in a comminuted metacarpal fracture model, double-row 3-dimensional non-locking plates provided superior stability in bending and equivalent stability in torsion compared with double-row 3-dimensional locking plates, whereas single-row non-locking plates provided the least stability.
Jackson, Timothy J; Adamson, Gregory J; Peterson, Alexander; Patton, John; McGarry, Michelle H; Lee, Thay Q
2013-05-01
Many ulnar collateral ligament (UCL) reconstruction techniques have been created and biomechanically tested. Single-bundle reconstructions aim to re-create the important anterior bundle of the UCL. To date, no technique has utilized suspensory fixation on the ulnar and humeral sides to create a single-bundle reconstruction. The bisuspensory technique will restore valgus laxity to its native state, with comparable load-to-failure characteristics to the docking technique. Controlled laboratory study. Six matched pairs of fresh-frozen cadaveric elbows were randomized to undergo UCL reconstruction using either the docking technique or a novel single-bundle bisuspensory technique. Valgus laxity and rotation measurements were quantified using a MicroScribe 3DLX digitizer at various flexion angles for the native ligament, transected ligament, and 1 of the 2 tested reconstructed ligaments. Laxity testing was performed from maximum extension to 120° of flexion. Each reconstruction was then tested to failure, and the method of failure was recorded. Valgus laxity was restored to the intact state at all degrees of elbow flexion for both the docking and bisuspensory techniques. In load-to-failure testing, there was no significant difference with regard to stiffness, ultimate torque, ultimate torque angle, energy absorbed, and applied moment to reach 10° of valgus. Yield torques for the bisuspensory and docking reconstructions were 18.7 ± 7.8 N·m and 18.6 ± 4.4 N·m, respectively (P = .95). The ultimate torque for the bisuspensory technique measured 26.5 ± 9.2 N·m and for the docking technique measured 25.1 ± 7.1 N·m (P = .78). The bisuspensory fixation technique, a reproducible single-bundle reconstruction, was able to restore valgus laxity to the native state, with similar load-to-failure characteristics as the docking technique. This reconstruction technique could be considered in a clinical setting as a primary method of UCL reconstruction or as a backup fixation method should intraoperative complications occur.
Bonin, Lucie; Pedreiro, Cécile; Moret, Stéphanie; Chene, Gautier; Gaucherand, Pascal; Lamblin, Géry
2017-01-01
We sought to evaluate the global success rate of intramuscular methotrexate for the treatment of ectopic pregnancy, identify factors predictive of treatment success or failure, and study methotrexate tolerability in a large patient cohort. For this single-center retrospective observational study, we retrieved the records of all women who had a clinically or echographically confirmed ectopic pregnancy with a Fernandez score <13 and who were treated according to a 1mg/kg intramuscular single-dose methotrexate protocol. Medical treatment failure was defined by an obligation to proceed to laparoscopy. Needing a second injection was not considered to be medical treatment failure. Between February 2008 and November 2013 (69 months), 400 women received methotrexate for ectopic pregnancy. The medical treatment protocol was effective for 314 patients, i.e., an overall success rate of 78.5%. A single methotrexate dose was sufficient for 63.5% of the women and a second dose was successful for 73.2% of the remaining women. The medical treatment success rate fell as initial hCG levels climbed. The main factors associated with methotrexate failure included day (D) 0, D4 and D7 hCG levels, pretherapeutic blood progesterone, hematosalpinx at D0 and pain at D7. Early favorable kinetics of hCG levels was predictive of success. Methotrexate treatment was successful in 90% of women who had D0 hCG <1000IU/l. Methotrexate tolerability was good, with only 9% of the women reporting non-severe adverse effects. The fertility rate with delivery after medical treatment for ectopic pregnancy was 80.7%. In this study, we showed that an initial hCG value <1000IU/l and favorable early HCG kinetics were predictive factors for the successful medical treatment of ectopic pregnancy by methotrexate, and hematosalpinx and pretherapeutic blood progesterone >5ng/ml at diagnosis were predictive of its failure. We also confirmed good tolerability for single-dose methotrexate protocols. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Development Testing and Subsequent Failure Investigation of a Spring Strut Mechanism
NASA Technical Reports Server (NTRS)
Dervan, Jared; Robertson, Brandan; Staab, Lucas; Culberson, Michael; Pellicciotti, Joseph
2014-01-01
The NASA Engineering and Safety Center (NESC) and Lockheed Martin (LM) performed random vibration testing on a single spring strut development unit to assess its ability to withstand qualification level random vibration environments. Failure of the strut while exposed to random vibration resulted in a follow-on failure investigation, design changes, and additional development tests. This paper focuses on the results of the failure investigations referenced in detail in the NESC final report [1] including identified lessons learned to aid in future design iterations of the spring strut and to help other mechanism developers avoid similar pitfalls.
Development Testing and Subsequent Failure Investigation of a Spring Strut Mechanism
NASA Technical Reports Server (NTRS)
Dervan, Jared; Robertson, Brandon; Staab, Lucas; Culberson, Michael; Pellicciotti, Joseph
2014-01-01
The NASA Engineering and Safety Center (NESC) and Lockheed Martin (LM) performed random vibration testing on a single spring strut development unit to assess its ability to withstand qualification level random vibration environments. Failure of the strut while exposed to random vibration resulted in a follow-on failure investigation, design changes, and additional development tests. This paper focuses on the results of the failure investigations referenced in detail in the NESC final report including identified lessons learned to aid in future design iterations of the spring strut and to help other mechanism developers avoid similar pitfalls.
Actuator digital interface unit (AIU). [control units for space shuttle data system
NASA Technical Reports Server (NTRS)
1973-01-01
Alternate versions of the actuator interface unit are presented. One alternate is a dual-failure immune configuration which feeds a look-and-switch dual-failure immune hydraulic system. The other alternate is a single-failure immune configuration which feeds a majority voting hydraulic system. Both systems communicate with the data bus through data terminals dedicated to each user subsystem. Both operational control data and configuration control information are processed in and out of the subsystem via the data terminal which yields the actuator interface subsystem, self-managing within its failure immunity capability.
NASA Technical Reports Server (NTRS)
Behbehani, K.
1980-01-01
A new sensor/actuator failure analysis technique for turbofan jet engines was developed. Three phases of failure analysis, namely detection, isolation, and accommodation are considered. Failure detection and isolation techniques are developed by utilizing the concept of Generalized Likelihood Ratio (GLR) tests. These techniques are applicable to both time varying and time invariant systems. Three GLR detectors are developed for: (1) hard-over sensor failure; (2) hard-over actuator failure; and (3) brief disturbances in the actuators. The probability distribution of the GLR detectors and the detectability of sensor/actuator failures are established. Failure type is determined by the maximum of the GLR detectors. Failure accommodation is accomplished by extending the Multivariable Nyquest Array (MNA) control design techniques to nonsquare system designs. The performance and effectiveness of the failure analysis technique are studied by applying the technique to a turbofan jet engine, namely the Quiet Clean Short Haul Experimental Engine (QCSEE). Single and multiple sensor/actuator failures in the QCSEE are simulated and analyzed and the effects of model degradation are studied.
NASA Astrophysics Data System (ADS)
Li, Xin; Zhang, Lu; Tang, Ying; Huang, Shanguo
2018-03-01
The light-tree-based optical multicasting (LT-OM) scheme provides a spectrum- and energy-efficient method to accommodate emerging multicast services. Some studies focus on the survivability technologies for LTs against a fixed number of link failures, such as single-link failure. However, a few studies involve failure probability constraints when building LTs. It is worth noting that each link of an LT plays different important roles under failure scenarios. When calculating the failure probability of an LT, the importance of its every link should be considered. We design a link importance incorporated failure probability measuring solution (LIFPMS) for multicast LTs under independent failure model and shared risk link group failure model. Based on the LIFPMS, we put forward the minimum failure probability (MFP) problem for the LT-OM scheme. Heuristic approaches are developed to address the MFP problem in elastic optical networks. Numerical results show that the LIFPMS provides an accurate metric for calculating the failure probability of multicast LTs and enhances the reliability of the LT-OM scheme while accommodating multicast services.
Out of sight, out of mind: why doesn't widespread clinical quality failure command our attention?
Milstein, Arnold; Adler, Nancy E
2003-01-01
This paper examines the tolerance by all stakeholders of increasingly well documented evidence of serious and widespread clinical quality failure in the United States. Using research evidence from psychology, it describes specific cognitive and motivational impediments to the perception of quality failure-those shared by all stakeholders and those particularly relevant to patients and their families and to health care professionals. The authors endorse efforts by the National Quality Forum and others to make quality failure more publicly visible. They also point to the pivotal role of health care industry leaders in sustaining focus on a problem that inherently resists visibility.
Niederhäuser, Simone K; Tepic, Slobodan; Weber, Urs T
2015-05-01
To evaluate the effect of screw position on strength and stiffness of a combination locking plate-rod construct in a synthetic feline femoral gap model. 30 synthetic long-bone models derived from beechwood and balsa wood. 3 constructs (2 locking plate-rod constructs and 1 locking plate construct; 10 specimens/construct) were tested in a diaphyseal bridge plating configuration by use of 4-point bending and torsion. Variables included screw position (near the fracture gap and far from the fracture gap) and application of an intramedullary pin. Constructs were tested to failure in each loading mode to determine strength and stiffness. Failure was defined as plastic deformation of the plate or breakage of the bone model or plate. Strength, yield angle, and stiffness were compared by use of a Wilcoxon test. Placement of screws near the fracture gap did not increase bending or torsional stiffness in the locking plate-rod constructs, assuming the plate was placed on the tension side of the bone. Addition of an intramedullary pin resulted in a significant increase in bending strength of the construct. Screw positioning did not have a significant effect on any torsion variables. Results of this study suggested that, in the investigated plate-rod construct, screw insertion adjacent to the fracture lacked mechanical advantages over screw insertion at the plate ends. For surgeons attempting to minimize soft tissue dissection, the decision to make additional incisions for screw placement should be considered with even more caution.
Gender aspects in heart failure. Pathophysiology and medical therapy.
Regitz-Zagrosek, V; Lehmkuhl, E; Lehmkuhl, H B; Hetzer, R
2004-09-01
Gender differences in the syndrome of heart failure (HF) occur in etiology and pathophysiology and lead to differences in the clinical presentation and course of the syndrome. In addition, gender specific treatment responses and gender associated differences in the behavior of treating physicians are found. Hypertension and diabetes play a major role as causes of HF in women and both interact in their pathophysiology with the renin angiotensin system (RAS). Modulation of the RAS by estrogens explains specific differences between pre- and post-menopausal women and men. Myocardial growth processes and myocardial calcium handling are differentially regulated in female and male myocytes. Myocardial remodeling with age and as a consequence of mechanical load differs in women and men. For yet unknown reasons, HF with preserved systolic function seems to be more frequent in women than in men and the clinical course of systolic HF is different in both genders. Medical therapy in heart failure has usually not been specified according to gender and gender specific analysis has been neglected in most large survival trials. Only a post-hoc analysis of gender differences led to the recognition of increased mortality with digitalis therapy in women. Single studies on angiotensin converting enzyme inhibitors (ACEI) or beta-receptor blockers did not reach significant end points in women whereas meta-analyses showed overall positive effects. Side effects of ACEI are more common and pharmacokinetics of beta-blockers are different in women. Angiotensin receptor blockers (ARB) are equally well tolerated in women and men. RAS inhibition may be particularly advantageous in postmenopausal women in whom the natural modulation of the RAS by estrogens is lost.
Elvik, Rune
2011-11-01
A large number of studies have tried to assess how various aspects of driver health influence driver involvement in accidents. The objective of this paper is to provide a framework for a critical assessment of the quality these studies from a methodological point of view. Examples are given of how various sources of bias and confounding can produce study findings that are highly misleading. Ten potential sources of error and bias in epidemiological studies of the contribution of driver health impairments to road accidents are discussed: (1) Poor description of the medical conditions whose effects are studied (measurement error). (2) Inadequate control for the effects of exposure on accident rate. (3) Sampling endogeneity with respect to assessment for fitness to drive (outcome-based sampling; self-selection bias). (4) Combined exposure to several risk factors. (5) Poor control for potentially confounding factors. (6) Failure to specify potentially moderating factors (interaction effects). (7) Failure to consider a severity gradient with respect to the effect of health impairments. (8) Failure to specify the compliance of drivers with medical treatments or treatment effectiveness. (9) No data on the population prevalence of various health conditions. (10) The use of multiple study approaches and methods making the comparison and synthesis of findings difficult. Examples are given of how all these items may influence the findings of a single study or make synthesising findings from multiple studies difficult. A checklist for assessing study quality is provided. Copyright © 2011 Elsevier Ltd. All rights reserved.
Selamet, Umut; Katz, Ronit; Ginsberg, Charles; Rifkin, Dena E; Fried, Linda F; Kritchevsky, Stephen B; Hoofnagle, Andrew N; Bibbins-Domingo, Kirsten; Drew, David; Harris, Tamara; Newman, Anne; Gutiérrez, Orlando M; Sarnak, Mark J; Shlipak, Michael G; Ix, Joachim H
2018-06-06
Lower 25-hydroxyvitamin D concentrations have been associated with risk for kidney function decline, heart failure, and mortality. However, 25-hydroxyvitamin D requires conversion to its active metabolite, calcitriol, for most biological effects. The associations of calcitriol concentrations with clinical events have not been well explored. Case-cohort study. Well-functioning community-living older adults aged 70 to 79 years at inception who participated in the Health, Aging, and Body Composition (Health ABC) Study. Serum calcitriol measured using positive ion electrospray ionization-tandem mass spectrometry. Major kidney function decline (≥30% decline in estimated glomerular filtration rate from baseline), incident heart failure (HF), and all-cause mortality during 10 years of follow-up. Baseline calcitriol concentrations were measured in a random subcohort of 479 participants and also in cases with major kidney function decline [n=397]) and incident HF (n=207) during 10 years of follow-up. Associations of serum calcitriol concentrations with these end points were evaluated using weighted Cox regression to account for the case-cohort design, while associations with mortality were assessed in the subcohort alone using unweighted Cox regression. During 8.6 years of mean follow-up, 212 (44%) subcohort participants died. In fully adjusted models, each 1-standard deviation lower calcitriol concentration was associated with 30% higher risk for major kidney function decline (95% CI, 1.03-1.65; P=0.03). Calcitriol was not significantly associated with incident HF (HR, 1.16; 95% CI, 0.94-1.47) or mortality (HR, 1.01; 95% CI, 0.81-1.26). We observed no significant interactions between calcitriol concentrations and chronic kidney disease status, baseline intact parathyroid or fibroblast factor 23 concentrations. Observational study design, calcitriol measurements at a single time point, selective study population of older adults only of white or black race. Lower calcitriol concentrations are independently associated with kidney function decline in community-living older adults. Future studies will be needed to clarify whether these associations reflect lower calcitriol concentrations resulting from abnormal kidney tubule dysfunction or direct mechanisms relating lower calcitriol concentrations to more rapid loss of kidney function. Published by Elsevier Inc.
Wessler, Jeffrey D; Maurer, Mathew S; Hummel, Scott L
2015-03-01
Heart failure (HF) is a major public health problem affecting predominantly older adults. Nonadherence to diet remains a significant contributor to acute decompensated HF (ADHF). The sodium-restricted Dietary Approaches to Stop Hypertension (DASH/SRD) eating plan reduces cardiovascular dysfunction that can lead to ADHF and is consistent with current HF guidelines. We propose that an intervention that promotes adherence to the DASH/SRD by home-delivering meals will be safe and improve health-related quality of life (QOL) in older adults after hospitalization for ADHF. This is a 3-center, randomized, single-blind, controlled trial of 12-week duration designed to determine the safety and efficacy of home-delivered DASH/SRD-compliant meals in older adults after discharge from ADHF hospitalization. Sixty-six subjects will be randomized in a 1:1 stratified fashion by gender and left ventricular ejection fraction (<50% vs ≥50%). Study subjects will receive either preprepared, home-delivered DASH/SRD-compliant meals or usual dietary advice for 4weeks after hospital discharge. Investigators will be blinded to group assignment, food diaries, and urinary electrolyte measurements until study completion. The primary efficacy end point is the change in the Kansas City Cardiomyopathy Questionnaire summary scores for health-related QOL from study enrollment to 4weeks postdischarge. Safety evaluation will focus on hypotension, renal insufficiency, and hyperkalemia. Exploratory end points include echocardiography, noninvasive vascular testing, markers of oxidative stress, and salt taste sensitivity. This randomized controlled trial will test the efficacy, feasibility, and safety of 4weeks of DASH/SRD after ADHF hospitalization. By testing a novel dietary intervention supported by multiple levels of evidence including preliminary data in outpatients with stable HF, we will address a critical evidence gap in the care of older patients with ADHF. If effective and safe, this intervention could be scaled to assess effects on readmission and healthcare costs in older adults after ADHF. Published by Elsevier Inc.
Management of Severe Pancreatic Fistula After Pancreatoduodenectomy
Smits, F. Jasmijn; van Santvoort, Hjalmar C.; Besselink, Marc G.; Batenburg, Marilot C. T.; Slooff, Robbert A. E.; Boerma, Djamila; Busch, Olivier R.; Coene, Peter P. L. O.; van Dam, Ronald M.; van Dijk, David P. J.; van Eijck, Casper H. J.; Festen, Sebastiaan; van der Harst, Erwin; de Hingh, Ignace H. J. T.; de Jong, Koert P.; Tol, Johanna A. M. G.; Borel Rinkes, Inne H. M.
2017-01-01
Importance Postoperative pancreatic fistula is a potentially life-threatening complication after pancreatoduodenectomy. Evidence for best management is lacking. Objective To evaluate the clinical outcome of patients undergoing catheter drainage compared with relaparotomy as primary treatment for pancreatic fistula after pancreatoduodenectomy. Design, Setting, and Participants A multicenter, retrospective, propensity-matched cohort study was conducted in 9 centers of the Dutch Pancreatic Cancer Group from January 1, 2005, to September 30, 2013. From a cohort of 2196 consecutive patients who underwent pancreatoduodenectomy, 309 patients with severe pancreatic fistula were included. Propensity score matching (based on sex, age, comorbidity, disease severity, and previous reinterventions) was used to minimize selection bias. Data analysis was performed from January to July 2016. Exposures First intervention for pancreatic fistula: catheter drainage or relaparotomy. Main Outcomes and Measures Primary end point was in-hospital mortality; secondary end points included new-onset organ failure. Results Of the 309 patients included in the analysis, 209 (67.6%) were men, and mean (SD) age was 64.6 (10.1) years. Overall in-hospital mortality was 17.8% (55 patients): 227 patients (73.5%) underwent primary catheter drainage and 82 patients (26.5%) underwent primary relaparotomy. Primary catheter drainage was successful (ie, survival without relaparotomy) in 175 patients (77.1%). With propensity score matching, 64 patients undergoing primary relaparotomy were matched to 64 patients undergoing primary catheter drainage. Mortality was lower after catheter drainage (14.1% vs 35.9%; P = .007; risk ratio, 0.39; 95% CI, 0.20-0.76). The rate of new-onset single-organ failure (4.7% vs 20.3%; P = .007; risk ratio, 0.15; 95% CI, 0.03-0.60) and new-onset multiple-organ failure (15.6% vs 39.1%; P = .008; risk ratio, 0.40; 95% CI, 0.20-0.77) were also lower after primary catheter drainage. Conclusions and Relevance In this propensity-matched cohort, catheter drainage as first intervention for severe pancreatic fistula after pancreatoduodenectomy was associated with a better clinical outcome, including lower mortality, compared with primary relaparotomy. PMID:28241220
Bagel, J; Tyring, S; Rice, K C; Collier, D H; Kricorian, G; Chung, J; Iles, J; Stolshek, B S; Kaliyaperumal, A; Papp, K A
2017-08-01
Some patients with plaque psoriasis experience secondary failure of tumour necrosis factor inhibitor therapy. To evaluate efficacy, safety and patient-reported outcomes (PROs) with etanercept in patients with secondary adalimumab failure. This phase IV open-label single-arm estimation study (NCT01543204) enrolled patients on adalimumab who had achieved static Physician's Global Assessment (sPGA) score 0/1 (clear/almost clear). Patients subsequently lost response, defined as sPGA ≥ 3 or loss of 50% improvement in Psoriasis Area and Severity Index (PASI 50). At baseline, patients had involved body surface area ≥ 10%, sPGA ≥ 3 and PASI ≥ 10. Antiadalimumab antibodies (ADAs) were measured at screening. Patients received etanercept 50 mg twice weekly for 12 weeks, followed by 50 mg weekly. The primary end point was sPGA 0/1 at week 12 (intention-to-treat analysis; no hypothesis tested). Additional outcomes included rates of sPGA 0/1, PASI responses, safety, PROs of itch, pain and flaking, Dermatology Life Quality Index, treatment satisfaction and Work Productivity and Activity Impairment questionnaire. Sixty-four patients enrolled; 67% had ADAs. sPGA 0/1 rates at week 12 were 39·7% [95% confidence interval (CI) 27·6-52·8; primary end point] and 45% (95% CI 29·3-61·5) for patients positive for ADAs and 35% (95% CI 15·4-59·2) for patients negative for ADAs. PASI 75 response rates at week 12 were 47·5% (95% CI 31·5-63·9) for patients who were positive for ADAs and 50% (95% CI 27·2-72·8) for patients negative for ADAs. No new safety signals were observed. PROs of itch, pain and flaking consistently improved at week 12 and were maintained through week 24. Patients with psoriasis who experienced secondary failure of adalimumab achieved satisfactory response to etanercept regardless of ADA status. © 2016 The Authors. British Journal of Dermatology published by John Wiley & Sons Ltd on behalf of British Association of Dermatologists.
Binder, G; Schwarze, C P; Ranke, M B
2000-01-01
Point mutations or complete deletions of SHOX, the short-stature homeobox-containing gene on the pseudoautosomal region of the sex chromosomes (Xp22 and Yp11.3), were recently reported in one family with idiopathic short stature and in several families with Leri-Weill syndrome (dyschondrosteosis). The missing SHOX is also thought to attribute to the growth failure in Turner syndrome. For testing the frequency of defects of SHOX in unexplained growth failure and recombinant human GH (rhGH) as a possible growth-promoting agent, we selected 68 children with idiopathic short stature. These probands had heights below -2.0 SD score for age, normal target heights, no significant bone age retardations, no endocrine abnormalities, no skeletal diseases, and no other organic diseases. No mutations were detected by single-strand conformational polymorphism analysis of the PCR-amplified SHOX. The analysis of three microsatellite DNA markers of the pseudoautosomal region, including one located on the 5' untranslated region of SHOX-exon 1, identified a 15-yr-old girl who carried a mutation in the form of a complete SHOX deletion. This girl who had a normal karyotype presented with mild mesomelic shortening of the forearms and lower legs. We treated two children with short stature on the basis of a SHOX point mutation (C674T) with rhGH at a dose of 1.0 IU/kg body weight-week in accordance with the regimen used in Turner syndrome. During the first 12 months of treatment, these two children (5.9- and 8.4-yr-old) showed an excellent growth spurt with a growth rate of 9.5 and 9.4 cm/yr, respectively. Growth of the lower extremities was weaker than in the trunk and arms. Our data suggest that short stature due to SHOX deletions is not a rare entity. Growth-promoting therapy with rhGH was effective with regard to height gain, but a tendency to disproportionate growth was apparent. In cases of unexplained growth failure, especially if associated with any mild skeletal disproportions, genetic analysis of SHOX should be considered.
2016-12-01
December 2016 3. REPORT TYPE AND DATES COVERED Master’s thesis 4. TITLE AND SUBTITLE A STUDY ON THE FAILURE OF CONVENTIONAL DETERRENCE: THE CASE ...Approved for public release. Distribution is unlimited A STUDY ON THE FAILURE OF CONVENTIONAL DETERRENCE: THE CASE STUDY OF THE BOMBARDMENT OF...necessary to analyze these diverse elements comprehensively. E. RESEARCH DESIGN This thesis focuses on a single case study about the bombardment of
Tsiouris, Athanasios; Paone, Gaetano; Nemeh, Hassan W; Brewer, Robert J; Borgi, Jamil; Hodari, Arielle; Morgan, Jeffrey A
2015-01-01
Continuous-flow (CF) left ventricular assist devices (LVADs) have become the standard of care for patients with advanced heart failure refractory to optimal medical therapy. The goal of this study was to review our 7 year single institutional experience with CF LVADs. Mean age was 50.4 + 12.5 (17-69) years for bridge-to-transplantation (BTT) patients and 57.6 + 10.4 (31-81) years for destination therapy (DT) patients (p < 0.001). Overall, 38 patients (26%) were female and 58 (41%) were African American. Etiology of heart failure was ischemic in 54 patients (37%) and nonischemic in 93 patients (63%). Overall survival at 30 days, 6 months, 12 months, and 2 years was 93%, 89%, 84%, and 81%, respectively. Gastrointestinal bleeding (GIB) was the most common complication (24%), followed by stroke (18%), right ventricular (RV) failure (18%), ventilator-dependent respiratory failure (10%), reoperation for bleeding (10%), and driveline infection (9%). These data demonstrate excellent survival with low mortality for both BTT and DT patients on long-term LVAD support. However, for LVAD therapy to become the gold standard for long-term treatment of end-stage heart failure and a plausible alternative to heart transplantation, we need to continue to improve the incidence of frequent postoperative complications, such as RV failure, driveline infections, strokes, and GIB.
Fatigue life characterization for piezoelectric macrofiber composites
NASA Astrophysics Data System (ADS)
Henslee, Isaac A.; Miller, David A.; Tempero, Tyler
2012-10-01
In an effort to aid the investigation into lightweight and reliable materials for actuator design, a study was developed to characterize the temperature-dependent lifetime performance of a piezoelectric macrofiber composite (MFC). MFCs are thin rectangular patches of polyimide film, epoxy and a single layer of rectangular lead zirconium titanate (PZT) fibers. In this study, the useful life of the MFC is characterized to determine the effect of temperature on the performance of the composite as it is fatigued by cyclic piezoelectric excitation. The test specimen consists of the MFC laminated to a cantilevered stainless steel beam. Beam strain and tip displacement measurements are used as a basis for determining the performance of the MFC as it is cyclically actuated under various operating temperatures. The temperature of the beam laminate is held constant and then cycled to failure, or 250 million cycles, in order to determine the useful life of the MFC over a temperature range from - 15 to 145 °C. The results of the experiments show a strong temperature dependence of the operational life for the MFC. Damage inside the composite was identified through in situ visual inspection and during post-test microstructural observation; however, no degradation in operational performance was identified as it was cyclically actuated up to the point of failure, regardless of temperature or actuation cycle number.
Design of ceramic components with the NASA/CARES computer program
NASA Technical Reports Server (NTRS)
Nemeth, Noel N.; Manderscheid, Jane M.; Gyekenyesi, John P.
1990-01-01
The ceramics analysis and reliability evaluation of structures (CARES) computer program is described. The primary function of the code is to calculate the fast-fracture reliability or failure probability of macro-scopically isotropic ceramic components. These components may be subjected to complex thermomechanical loadings, such as those found in heat engine applications. CARES uses results from MSC/NASTRAN or ANSYS finite-element analysis programs to evaluate how inherent surface and/or volume type flaws component reliability. CARES utilizes the Batdorf model and the two-parameter Weibull cumulative distribution function to describe the effects of multiaxial stress states on material strength. The principle of independent action (PIA) and the Weibull normal stress averaging models are also included. Weibull material strength parameters, the Batdorf crack density coefficient, and other related statistical quantities are estimated from four-point bend bar or uniform uniaxial tensile specimen fracture strength data. Parameter estimation can be performed for a single or multiple failure modes by using a least-squares analysis or a maximum likelihood method. Kolmogorov-Smirnov and Anderson-Darling goodness-to-fit-tests, 90 percent confidence intervals on the Weibull parameters, and Kanofsky-Srinivasan 90 percent confidence band values are also provided. Examples are provided to illustrate the various features of CARES.
Vestibular and oculomotor findings in neurologically-normal, non-concussed children.
Corwin, Daniel J; Zonfrillo, Mark R; Wiebe, Douglas J; Master, Christina L; Grady, Matthew F; Arbogast, Kristy B
2018-01-01
To determine the proportion of non-concussed, neurologically normal children with failures on a vestibular and oculomotor examination for concussion performed in an acute setting. This was a cross-sectional study of subjects 6-18 years old presenting to a paediatric emergency department with non-neurologic chief complaints. The examination was administered by a paediatric emergency medicine physician, and includes assessments of dysmetria, nystagmus, smooth pursuits, saccades, gaze stability, near-point of convergence, and gait/balance testing. Of the 295 subjects enrolled, 24% failed at least one element of testing. About 13% had >1 failed element and 5% had >2 failed elements. About 29% of females and 19% of males had failed examinations. By age, 15% of subjects 6-8 years old, 32% 9-11 years, 32% 12-14 years, and 26% 15-18 years had failed examinations. Overall, 10% were unable to complete the exam due to developmental age. The provider should be aware that a proportion of non-concussed children may demonstrate failure on a single element of the vestibular and oculomotor exam. While this testing is of benefit to the acute care provider in diagnosing paediatric concussion, its utility is greatest in the context of an injury history with acute onset of concussion symptoms.
Ziman, Melanie E; Bui, Hien T; Smith, Craig S; Tsukiji, Lori A; Asmatey, Veda M; Chu, Steven B; Miano, John S
2012-04-01
This single-center retrospective pilot program's objective was to utilize outpatient pharmacists to improve laboratory test adherence in chronic heart failure (CHF) patients overdue for thyroid function testing, thereby demonstrating the value of the outpatient pharmacist and justifying possible clinical role expansion. Thyroid disorders may contribute to CHF development, progression, and exacerbation. Testing is the standard of care in CHF patients per American Heart Association's 2009 Guidelines. Delinquency was defined as labs not conducted within 1 year in patients with euthyroid history, within 6 months in patients with thyroid dysfunction, abnormal labs at any time without follow-up, or lab absence after thyroid medication initiation, adjustment, or discontinuation. Targeted 80 nonpregnant adult CHF patients with delinquent thyroid function tests were counseled to get thyroid labs at point of sale, via telephone, e-mail, or letter. In collaboration with physicians, pharmacists ordered thyroid-stimulating hormone (TSH) and free T4 (FT4) labs. For patients with abnormal laboratory results, pharmacists coordinated drug therapy and follow-up labs. Data were collected from November 1, 2009 to March 30, 2010. Seventy-two patients (90%) previously delinquent for thyroid function testing received relevant thyroid labs. Ten patients (12.5%) with abnormal thyroid function tests not on prior drug therapy received treatment.
ElSheemy, Mohammed S; Fathy, Hesham; Hussein, Hussein A; Hussein, Eman A; Hassan, Sarah Mohamed
2015-06-01
To compare safety and efficacy of surgeon-tailored polypropylene mesh through needleless single-incision technique (STM) versus tension-free vaginal tape-obturator (TVT-O) aiming to decrease cost of treatment of stress urinary incontinence (SUI). This is important in developing countries due to limited healthcare resources. A retrospective cohort study was done at Urology and Gynecology Departments (dual-center), Cairo University, from January 2011 to August 2013. STM was inserted in 72 females, while TVT-O was inserted in 48 females. Females evaluated by cough stress test, stress and urge incontinence quality of life questionnaire (SUIQQ), Q max and abdominal leak point pressure (ALPP) were included. Different factors were compared between both groups using paired t, Wilcoxon's signed rank, McNemar, Chi-square, Fisher's exact, independent t or Mann-Whitney tests. Age, parity, previous surgeries, ALPP, intrinsic sphincter deficiency (ISD), associated prolapse and associated prolapse repair were comparable in both groups. No significant difference was found between both groups in postoperative complications (except groin pain), cure, SUIQQ indices improvement and Q max decline. In total, 65 (90 %) cured, 6 (8 %) improved while failure was detected in one (1 %) patient in STM group, while 42 (87 %) cured, 4 (8 %) improved and failure was detected in two (4 %) patients in TVT-O group. Presence of ISD (p = 0.565), urgency (p = 0.496), UUI (p = 0.531), previous surgeries (p = 0.345), associated urogenital prolapse (p = 0.218) or associated prolapse repair (p = 0.592) did not lead to any significant difference in outcome between both groups. Cost of mesh decreased from US$500 (TVT-O) to US$10 (STM). Outcome of STM is comparable to TVT-O. Furthermore, STM is more economic.
Peer-to-peer Cooperative Scheduling Architecture for National Grid Infrastructure
NASA Astrophysics Data System (ADS)
Matyska, Ludek; Ruda, Miroslav; Toth, Simon
For some ten years, the Czech National Grid Infrastructure MetaCentrum uses a single central PBSPro installation to schedule jobs across the country. This centralized approach keeps a full track about all the clusters, providing support for jobs spanning several sites, implementation for the fair-share policy and better overall control of the grid environment. Despite a steady progress in the increased stability and resilience to intermittent very short network failures, growing number of sites and processors makes this architecture, with a single point of failure and scalability limits, obsolete. As a result, a new scheduling architecture is proposed, which relies on higher autonomy of clusters. It is based on a peer to peer network of semi-independent schedulers for each site or even cluster. Each scheduler accepts jobs for the whole infrastructure, cooperating with other schedulers on implementation of global policies like central job accounting, fair-share, or submission of jobs across several sites. The scheduling system is integrated with the Magrathea system to support scheduling of virtual clusters, including the setup of their internal network, again eventually spanning several sites. On the other hand, each scheduler is local to one of several clusters and is able to directly control and submit jobs to them even if the connection of other scheduling peers is lost. In parallel to the change of the overall architecture, the scheduling system itself is being replaced. Instead of PBSPro, chosen originally for its declared support of large scale distributed environment, the new scheduling architecture is based on the open-source Torque system. The implementation and support for the most desired properties in PBSPro and Torque are discussed and the necessary modifications to Torque to support the MetaCentrum scheduling architecture are presented, too.
An experimental investigation on the three-point bending behavior of composite laminate
NASA Astrophysics Data System (ADS)
A, Azzam; W, Li
2014-08-01
The response of composite laminate structure to three-point bending load was investigated by subjecting two types of stacking sequences of composite laminate structure by using electronic universal tester (Type: WDW-20) machine. Optical microscope was selected in order to characterize bending damage, delamination, and damage shapes in composite laminate structures. The results showed that the [0/90/-45/45]2s exhibits a brittle behavior, while other laminates exhibit a progressive failure mode consisting of fiber failure, debonding (splitting), and delamination. The [45/45/90/0]2s laminate has a highly nonlinear load- displacement curve due to compressive yielding.
Sharma, Rajinder P; Ree, Chung Ja; Ree, Alexander
2008-01-01
PURPOSE: To evaluate the effectiveness and safety of a single 2 mg dose or a 4 mg double dose of alteplase for restoring function in occluded chest ports. METHODS: A prospective, open-label, nonblinded study was performed on 40 enrolled patients with a total of 50 chest ports at the Henry Ford Hospital Interventional Radiology Department (Detroid, Michigan, USA). Alteplase (Cathflo Activase; Genentech, USA), a recombinant tissue plasminogen activator produced by recombinant DNA technology, was used to restore the function of 50 occluded chest ports. Occlusion was defined as the inability to withdraw blood freely from the port, or the inability to flush the port easily. A 2 mg (2 mL) dose of alteplase was injected into the port through a Huber needle, using a gentle push and pull technique, and was left to dwell for 30 min. If the port remained occluded after the initial 2 mg alteplase treatment, an additional 2 mg alteplase treatment was administered with the same dwell time of 30 min. If a port had remained occluded despite the above regimen, this outcome would have been considered a failure and the chest port would have required surgical intervention. However, all ports were successfully treated, and no surgical intervention was required. The safety end points included minor or major hemorrhages, such as intracranial hemorrhages, or sepsis. Safety end points were determined by a 24 h follow-up telephone call. RESULTS: Of the 50 chest ports (30 single ports and 10 double ports) treated with alteplase, 36 required 2 mg (72%) and 14 required 4 mg (28%). The efficacy end point was 100% for all chest ports treated, without any adverse events. CONCLUSION: High efficacy and safety rates of restoring function in occluded chest ports were obtained with 2 mg or 4 mg doses of alteplase. Part of this high efficacy rate may be due to the gentle push and pull technique used in the present study. PMID:22477414
Rosenblum, William I
2014-05-01
Before amyloid formation, peptides cleaved from the amyloid precursor protein (APP) exist as soluble oligomers. These are extremely neurotoxic. Their concentration is strongly correlated with synaptic impairment in animals and parallel cognitive decline in animals and humans. Clinical trials have largely been aimed at removing insoluble beta amyloid in senile plaques and have not reduced soluble load. Even treatment that should remove soluble oligomers has not consistently reduced the load. Failure to significantly improve cognition has frequently been attributed to failure of the amyloid hypothesis or to irreversible alteration in the brain. Instead, trial failures may be because of failure to significantly reduce load of toxic Aβ oligomers. Moreover, targeting only synthesis of Aβ peptides, only the oligomers themselves, or only the final insoluble amyloid may fail to significantly reduce soluble load because of the interrelationship between these 3 points in the amyloid cascade. Thus, treatments may fail unless trials target simultaneously all 3 points in the equation-"triple therapy". Cerebrospinal fluid analysis and other monitoring tools may in the future provide reliable measurement of soluble load. But currently, only analysis of autopsied brains can provide this data and thus enable proper evaluation and explanation of the outcome of clinical trials. These data are essential before attributing trial failures to the advanced nature of the disease or asserting that failures prove that the theory linking Alzheimer's disease to products of amyloid precursor protein is incorrect. Copyright © 2014 Elsevier Inc. All rights reserved.
Predicting failure: acoustic emission of berlinite under compression.
Nataf, Guillaume F; Castillo-Villa, Pedro O; Sellappan, Pathikumar; Kriven, Waltraud M; Vives, Eduard; Planes, Antoni; Salje, Ekhard K H
2014-07-09
Acoustic emission has been measured and statistical characteristics analyzed during the stress-induced collapse of porous berlinite, AlPO4, containing up to 50 vol% porosity. Stress collapse occurs in a series of individual events (avalanches), and each avalanche leads to a jerk in sample compression with corresponding acoustic emission (AE) signals. The distribution of AE avalanche energies can be approximately described by a power law p(E)dE = E(-ε)dE (ε ~ 1.8) over a large stress interval. We observed several collapse mechanisms whereby less porous minerals show the superposition of independent jerks, which were not related to the major collapse at the failure stress. In highly porous berlinite (40% and 50%) an increase of energy emission occurred near the failure point. In contrast, the less porous samples did not show such an increase in energy emission. Instead, in the near vicinity of the main failure point they showed a reduction in the energy exponent to ~ 1.4, which is consistent with the value reported for compressed porous systems displaying critical behavior. This suggests that a critical avalanche regime with a lack of precursor events occurs. In this case, all preceding large events were 'false alarms' and unrelated to the main failure event. Our results identify a method to use pico-seismicity detection of foreshocks to warn of mine collapse before the main failure (the collapse) occurs, which can be applied to highly porous materials only.
Stability in a fiber bundle model: Existence of strong links and the effect of disorder
NASA Astrophysics Data System (ADS)
Roy, Subhadeep
2018-05-01
The present paper deals with a fiber bundle model which consists of a fraction α of infinitely strong fibers. The inclusion of such an unbreakable fraction has been proven to affect the failure process in early studies, especially around a critical value αc. The present work has a twofold purpose: (i) a study of failure abruptness, mainly the brittle to quasibrittle transition point with varying α and (ii) variation of αc as we change the strength of disorder introduced in the model. The brittle to quasibrittle transition is confirmed from the failure abruptness. On the other hand, the αc is obtained from the knowledge of failure abruptness as well as the statistics of avalanches. It is observed that the brittle to quasibrittle transition point scales to lower values, suggesting more quasi-brittle-like continuous failure when α is increased. At the same time, the bundle becomes stronger as there are larger numbers of strong links to support the external stress. High α in a highly disordered bundle leads to an ideal situation where the bundle strength, as well as the predictability in failure process is very high. Also, the critical fraction αc, required to make the model deviate from the conventional results, increases with decreasing strength of disorder. The analytical expression for αc shows good agreement with the numerical results. Finally, the findings in the paper are compared with previous results and real-life applications of composite materials.
Food and Drug Administration (FDA) drug approval end points for chronic cutaneous ulcer studies.
Eaglstein, William H; Kirsner, Robert S; Robson, Martin C
2012-01-01
The rising costs of caring for chronic cutaneous ulcers (CCUs) and recent appreciation of the mortality of CCUs have led to consideration of the reasons for the failure to have new drug therapies. No new chemical entities to heal CCUs have been approved by the Food and Drug Administration (FDA) in over a decade, in part due to an inability to reach the FDA accepted end point of "complete wound closure." The frequent failure to reach the complete closure end point brings forward the question of the relevance of other healing end points such as improved quality of life, or partial healing. Because CCUs carry a prognosis and mortality rate worse than many cancers, it is reasonable to compare the FDA trial end points for cancer drug approval with those for CCUs. And the difference is quite striking. While there is only one end point for CCUs, there are five surrogate and three direct end points for cancers. In contrast to cancer, surrogate end points and partial healing are not acceptable for therapies aimed at CCUs. For example, making tumors smaller is an acceptable end point, but making CCUs smaller is not and improvement in the signs and symptoms of cancer is an acceptable end point for cancers but not CCUs. As CCUs carry a prognosis and mortality rate worse than many cancers, we believe a reconsideration of end points for CCUs is highly warranted. © 2012 by the Wound Healing Society.
Representing ductile damage with the dual domain material point method
Long, C. C.; Zhang, D. Z.; Bronkhorst, C. A.; ...
2015-12-14
In this study, we incorporate a ductile damage material model into a computational framework based on the Dual Domain Material Point (DDMP) method. As an example, simulations of a flyer plate experiment involving ductile void growth and material failure are performed. The results are compared with experiments performed on high purity tantalum. We also compare the numerical results obtained from the DDMP method with those obtained from the traditional Material Point Method (MPM). Effects of an overstress model, artificial viscosity, and physical viscosity are investigated. Our results show that a physical bulk viscosity and overstress model are important in thismore » impact and failure problem, while physical shear viscosity and artificial shock viscosity have negligible effects. A simple numerical procedure with guaranteed convergence is introduced to solve for the equilibrium plastic state from the ductile damage model.« less
Multiple Fault Isolation in Redundant Systems
NASA Technical Reports Server (NTRS)
Pattipati, Krishna R.; Patterson-Hine, Ann; Iverson, David
1997-01-01
Fault diagnosis in large-scale systems that are products of modern technology present formidable challenges to manufacturers and users. This is due to large number of failure sources in such systems and the need to quickly isolate and rectify failures with minimal down time. In addition, for fault-tolerant systems and systems with infrequent opportunity for maintenance (e.g., Hubble telescope, space station), the assumption of at most a single fault in the system is unrealistic. In this project, we have developed novel block and sequential diagnostic strategies to isolate multiple faults in the shortest possible time without making the unrealistic single fault assumption.
Multiple Fault Isolation in Redundant Systems
NASA Technical Reports Server (NTRS)
Pattipati, Krishna R.
1997-01-01
Fault diagnosis in large-scale systems that are products of modem technology present formidable challenges to manufacturers and users. This is due to large number of failure sources in such systems and the need to quickly isolate and rectify failures with minimal down time. In addition, for fault-tolerant systems and systems with infrequent opportunity for maintenance (e.g., Hubble telescope, space station), the assumption of at most a single fault in the system is unrealistic. In this project, we have developed novel block and sequential diagnostic strategies to isolate multiple faults in the shortest possible time without making the unrealistic single fault assumption.
NASA Technical Reports Server (NTRS)
Naumann, R. J.; Oran, W. A.; Whymark, R. R.; Rey, C.
1981-01-01
The single axis acoustic levitator that was flown on SPAR VI malfunctioned. The results of a series of tests, analyses, and investigation of hypotheses that were undertaken to determine the probable cause of failure are presented, together with recommendations for future flights of the apparatus. The most probable causes of the SPAR VI failure were lower than expected sound intensity due to mechanical degradation of the sound source, and an unexpected external force that caused the experiment sample to move radially and eventually be lost from the acoustic energy well.
A DFT study on the failure mechanism of Al2O3 film by various point defects in solution
NASA Astrophysics Data System (ADS)
Zhang, Chuan-Hui; Chen, Bao; Jin, Ying; Sun, Dong-Bai
2018-03-01
The defects on oxide film surface are very important, and they would occur when the film is peeled or scratched. The periodic DFT calculations have been performed on Al2O3 surface to model the influences of various point-defects. Three kinds of point defect surfaces (vacancy, inversion, substitution) are considered, and the molecular H2O dissociation and the transition state are calculated. The predicted formation energy of O vacancy is 8.30 eV, whereas that corresponding to the formation of Al vacancy is found to be at least a 55% larger. On the vacancy point defect surfaces, upward H2O molecule surfaces prefer to occur chemical reaction, leading the surfaces to be hydroxylated. And then the D-Cl-substitution-Al surface is corroded, which suggests a Cl adsorption induced failure mechanism of the oxide film. At last, the process of H2O dissociation on the OH-substitution-Al surfaces with four or five transition paths are discussed.
NASA Astrophysics Data System (ADS)
Tingley, Daniel Arthur
The reinforcement of wood and wood composite structural products to improve their mechanical properties has been in practice for many years. Recently, the use of high-strength fiber-reinforced plastic (FRP) as a reinforcement in such applications has been commercialized. The reinforcement is manufactured using a standard pultrusion process or alternatively a sheet-forming process commonly referred to as "pulforming". The high-modulus fibers are predominately unidirectional, although off-axis fibers are often used to enhance off-axis properties. The fibers used are either of a single type or multiple types, which are called "hybrids". Unidirectional, single, and hybrid fiber FRP physical properties and characteristics were compared to wood. Full-scale reinforced glulams were tested. Aramid-reinforced plastics (ARP) used as tensile reinforcements were found to be superior in strength applications to other types of FRP made with fiber, such as carbon and fiberglass. Carbon/aramid-reinforced plastic (CARP) was shown to be superior in both modulus and strength design situations. Fiberglass was shown to be suitable only in hybrid situations with another fiber such as aramid or carbon and only in limited use situations where modulus was a design criteria. The testing and analysis showed that the global response of reinforced glulam beams is controlled by localized strength variations in the wood such as slope of grain, knots, finger joints, etc. in the tensile zone. The elemental tensile strains in the extreme wood tensile laminae, due to global applied loads, were found to be well below the strain at failure in clear wood samples recovered from the failure area. Two areas affecting the relationship between the wood and the FRP were investigated: compatibility of the wood and FRP materials and interface characteristics between the wood and FRP. The optimum strain value at yield point for an FRP was assessed to be slightly higher than the clear wood value in tension for a species/grade to be reinforced. The effects of localized strength variations in the tensile wood laminae adjacent to the FRP were found to be the predominate cause of failure in full-scale reinforced glulams with less than 1.5% by cross section reinforcement.
Accurate Prediction of Motor Failures by Application of Multi CBM Tools: A Case Study
NASA Astrophysics Data System (ADS)
Dutta, Rana; Singh, Veerendra Pratap; Dwivedi, Jai Prakash
2018-02-01
Motor failures are very difficult to predict accurately with a single condition-monitoring tool as both electrical and the mechanical systems are closely related. Electrical problem, like phase unbalance, stator winding insulation failures can, at times, lead to vibration problem and at the same time mechanical failures like bearing failure, leads to rotor eccentricity. In this case study of a 550 kW blower motor it has been shown that a rotor bar crack was detected by current signature analysis and vibration monitoring confirmed the same. In later months in a similar motor vibration monitoring predicted bearing failure and current signature analysis confirmed the same. In both the cases, after dismantling the motor, the predictions were found to be accurate. In this paper we will be discussing the accurate predictions of motor failures through use of multi condition monitoring tools with two case studies.
Noah, Moronke A; Ramachandra, Geethanjali; Hickey, Margaret M; Jenkins, David R; Harvey, Chris J; Westrope, Claire A; Firmin, Richard K; Peek, Giles J
2013-01-01
Legionella-associated respiratory failure has a high mortality, despite modern ventilation modalities. Extracorporeal membrane oxygenation (ECMO) is used to achieve gas exchange independent of pulmonary function in patients with severe respiratory failure. This was a retrospective review of the management and outcome of patients with Legionella-associated respiratory failure treated with ECMO support in a large ECMO center over the past 10 years. A retrospective review of patients with confirmed Legionella-associated severe respiratory failure managed with ECMO support at a single center. Between 2000 and 2010, 19 patients with severe respiratory failure caused by Legionella were managed with ECMO after failure to respond to conventional intensive care management. Median PaO2/FiO2 ratio was 66 and median pCO2 was 60 torr. Sixteen patients (84%) survived to hospital discharge. Extracorporeal membrane oxygenation should be considered in patients with Legionella-associated respiratory failure, who have failed conventional ventilation.
Wilson, D A; Keegan, K G; Carson, W L
1999-01-01
This study compared the mechanical properties of the normal intact suspensory apparatus and two methods of fixation for repair of transverse, midbody fractures of the proximal sesamoid bones of adult horses: transfixation wiring (TW) and screws placed in lag fashion (LS). An in vitro, paired study using equine cadaver limbs mounted in a loading apparatus was used to test the mechanical properties of TW and LS. Seventeen paired (13 repaired, 4 normal) equine cadaver limbs consisting of the suspensory apparatus third metacarpal bone, and first and second phalanges. The two methods of repair and normal intact specimens were evaluated in single cycle-to-failure loading. Yield failure was defined to occur at the first notable discontinuity (>50 N) in the load-displacement curve, the first visible failure as evident on the videotape, or a change in the slope of the moment-fetlock angle curve. Ultimate failure was defined to occur at the highest load resisted by the specimen. Corresponding resultant force and force per kg of body weight on the suspensory apparatus, fetlock joint moment, and angle of fetlock dorsiflexion were calculated by use of specimen dimensions and applied load. These were compared along with specimen stiffness, and ram displacement. Load on the suspensory apparatus, load on the suspensory apparatus per kg of body weight, moment, applied load, and angle of fetlock dorsiflexion at yield failure were significantly greater for the TW-repaired than for the LS-repaired specimens. A 3 to 5 mm gap was observed before yield failure in most TW-repaired osteotomies. Transfixation wiring provided greater strength to yield failure than screws placed in lag fashion in single cycle load-to-failure mechanical testing of repaired transverse osteotomized specimens of the medial proximal forelimb sesamoid bone.
Computational hydraulics of a cascade of experimental-scale landside dam failures
NASA Astrophysics Data System (ADS)
Wright, N.; Guan, M.
2015-12-01
Abstract: Landslide dams typically comprise unconsolidated and poorly sorted material, and are vulnerable to rapid failure and breaching, particularly in mountainous areas during high intense rainfalls. A large flash flood with high-concentrated sediment can be formed in a short period, and the magnitude is likely to be amplified along the flow direction due to the inclusion of a large amount of sediment. This can result in significant and sudden flood risk downstream for human life and property. Numerous field evidence has indicated the various risks of landslide dam failures. In general, cascading landslide dams can be formed along the sloping channel due to the randomness and unpredictability of landslides, which complexes the hydraulics of landslide dam failures. The failure process of a single dam and subsequent floods has attracted attention in multidisciplinary studies. However, the dynamic failure process of cascading landslide dams has been poorly understood. From a viewpoint of simulation, this study evaluates the formation and development of rapid sediment-charged floods due to cascading failure of landslide dams through detailed hydro-morphodynamic modelling. The model used is based on shallow water theory and it has been successful in predicting the flow and morphological process during sudden dam-break, as well as full and partial dyke-breach. Various experimental-scale scenarios are modelled, including: (1) failure of a single full dam in a sloping channel, (2) failure of two dams in a sloping channel, (3) failure of multiple landslide dams (four) in a sloping channel. For each scenario, different failure modes (sudden/gradual) and bed boundary (fixed /mobile) are assumed and simulated. The study systematically explores the tempo-spatial evolution of landslide-induced floods (discharge, flow velocity, and flow concentration) and geomorphic properties along the sloping channel. The effects of in-channel erosion and flow-driven sediment from dams on the development of flood process are investigated. The results improve the understanding of the formation and development mechanism of flash floods due to cascading landslide dam failures. The findings are beneficial for downstream flood risk assessment and developing control strategies for landslide-induced floods.
A biomechanical comparison of single and double-row fixation in arthroscopic rotator cuff repair.
Smith, Christopher D; Alexander, Susan; Hill, Adam M; Huijsmans, Pol E; Bull, Anthony M J; Amis, Andrew A; De Beer, Joe F; Wallace, Andrew L
2006-11-01
The optimal method for arthroscopic rotator cuff repair is not yet known. The hypothesis of the present study was that a double-row repair would demonstrate superior static and cyclic mechanical behavior when compared with a single-row repair. The specific aims were to measure gap formation at the bone-tendon interface under static creep loading and the ultimate strength and mode of failure of both methods of repair under cyclic loading. A standardized tear of the supraspinatus tendon was created in sixteen fresh cadaveric shoulders. Arthroscopic rotator cuff repairs were performed with use of either a double-row technique (eight specimens) or a single-row technique (eight specimens) with nonabsorbable sutures that were double-loaded on a titanium suture anchor. The repairs were loaded statically for one hour, and the gap formation was measured. Cyclic loading to failure was then performed. Gap formation during static loading was significantly greater in the single-row group than in the double-row group (mean and standard deviation, 5.0 +/- 1.2 mm compared with 3.8 +/- 1.4 mm; p < 0.05). Under cyclic loading, the double-row repairs failed at a mean of 320 +/- 96.9 N whereas the single-row repairs failed at a mean of 224 +/- 147.9 N (p = 0.058). Three single-row repairs and three double-row repairs failed as a result of suture cut-through. Four single-row repairs and one double-row repair failed as a result of anchor or suture failure. The remaining five repairs did not fail, and a midsubstance tear of the tendon occurred. Although more technically demanding, the double-row technique demonstrates superior resistance to gap formation under static loading as compared with the single-row technique. A double-row reconstruction of the supraspinatus tendon insertion may provide a more reliable construct than a single-row repair and could be used as an alternative to open reconstruction for the treatment of isolated tears.
Silencing the Patient: Freud, Sexual Abuse, and "The Etiology of Hysteria."
ERIC Educational Resources Information Center
McOmber, James B.
1996-01-01
States that, in "The Etiology of Hysteria," Sigmund Freud's "seduction theory" asserted that child sexual abuse was the single cause of adult hysteria. Argues that Freud's failure to persuade his audience can be attributed not only to their denial of sexual abuse but also to his failure to clarify how pschyoanalysis could…
30 CFR 18.68 - Tests for intrinsic safety.
Code of Federal Regulations, 2012 CFR
2012-07-01
... requirements may be added at any time if features of construction or use or both indicate them to be necessary.... They shall be designed to withstand a test voltage of 1,500 volts. (4) Intrinsically safe circuits shall be so designed that after failure of a single component, and subsequent failures resulting from...
30 CFR 18.68 - Tests for intrinsic safety.
Code of Federal Regulations, 2011 CFR
2011-07-01
... requirements may be added at any time if features of construction or use or both indicate them to be necessary.... They shall be designed to withstand a test voltage of 1,500 volts. (4) Intrinsically safe circuits shall be so designed that after failure of a single component, and subsequent failures resulting from...
30 CFR 18.68 - Tests for intrinsic safety.
Code of Federal Regulations, 2010 CFR
2010-07-01
... requirements may be added at any time if features of construction or use or both indicate them to be necessary.... They shall be designed to withstand a test voltage of 1,500 volts. (4) Intrinsically safe circuits shall be so designed that after failure of a single component, and subsequent failures resulting from...
30 CFR 18.68 - Tests for intrinsic safety.
Code of Federal Regulations, 2013 CFR
2013-07-01
... requirements may be added at any time if features of construction or use or both indicate them to be necessary.... They shall be designed to withstand a test voltage of 1,500 volts. (4) Intrinsically safe circuits shall be so designed that after failure of a single component, and subsequent failures resulting from...
49 CFR 571.105 - Standard No. 105; Hydraulic and electric brake systems.
Code of Federal Regulations, 2014 CFR
2014-10-01
... current, and which may include a non-electrical source of power designed to charge batteries and... dissipating electrical energy. Skid number means the frictional resistance of a pavement measured in..., designed so that a single failure in any subsystem (such as a leakage-type failure of a pressure component...
49 CFR 571.105 - Standard No. 105; Hydraulic and electric brake systems.
Code of Federal Regulations, 2012 CFR
2012-10-01
... current, and which may include a non-electrical source of power designed to charge batteries and... dissipating electrical energy. Skid number means the frictional resistance of a pavement measured in..., designed so that a single failure in any subsystem (such as a leakage-type failure of a pressure component...
49 CFR 571.105 - Standard No. 105; Hydraulic and electric brake systems.
Code of Federal Regulations, 2013 CFR
2013-10-01
... current, and which may include a non-electrical source of power designed to charge batteries and... dissipating electrical energy. Skid number means the frictional resistance of a pavement measured in..., designed so that a single failure in any subsystem (such as a leakage-type failure of a pressure component...
14 CFR 25.809 - Emergency exit arrangement.
Code of Federal Regulations, 2013 CFR
2013-01-01
...-boost or single power-operated system is the primary system for operating more than one exit in an... effort; and must be arranged and marked so that it can be readily located and operated, even in darkness... event of failure of the primary system. Manual operation of the exit (after failure of the primary...
14 CFR 25.809 - Emergency exit arrangement.
Code of Federal Regulations, 2012 CFR
2012-01-01
...-boost or single power-operated system is the primary system for operating more than one exit in an... effort; and must be arranged and marked so that it can be readily located and operated, even in darkness... event of failure of the primary system. Manual operation of the exit (after failure of the primary...
14 CFR 25.809 - Emergency exit arrangement.
Code of Federal Regulations, 2010 CFR
2010-01-01
...-boost or single power-operated system is the primary system for operating more than one exit in an... effort; and must be arranged and marked so that it can be readily located and operated, even in darkness... event of failure of the primary system. Manual operation of the exit (after failure of the primary...
14 CFR 25.809 - Emergency exit arrangement.
Code of Federal Regulations, 2014 CFR
2014-01-01
...-boost or single power-operated system is the primary system for operating more than one exit in an... effort; and must be arranged and marked so that it can be readily located and operated, even in darkness... event of failure of the primary system. Manual operation of the exit (after failure of the primary...
Electromigration resistance in a short three-contact interconnect tree
NASA Astrophysics Data System (ADS)
Chang, C. W.; Choi, Z.-S.; Thompson, C. V.; Gan, C. L.; Pey, K. L.; Choi, W. K.; Hwang, N.
2006-05-01
Electromigration has been characterized in via-terminated interconnect lines with additional vias in the middle, creating two adjacent segments that can be stressed independently. The mortality of a segment was found to depend on the direction and magnitude of the current in the adjacent segment, confirming that there is not a fixed value of the product of the current density and segment length, jL, that defines immortality in individual segments that are part of a multisegment interconnect tree. Instead, it is found that the probability of failure of a multisegment tree increases with the increasing value of an effective jL product defined in earlier work. However, contrary to expectations, the failures were still observed when (jL)eff was less than the critical jL product for which lines were found to be immortal in single-segment test structures. It is argued that this is due to reservoir effects associated with unstressed segments or due to liner failure at the central via. Multisegment test structures are therefore shown to reveal more types of failure mechanisms and mortality conditions that are not found in tests with single-segment structures.
Rocket engine diagnostics using qualitative modeling techniques
NASA Technical Reports Server (NTRS)
Binder, Michael; Maul, William; Meyer, Claudia; Sovie, Amy
1992-01-01
Researchers at NASA Lewis Research Center are presently developing qualitative modeling techniques for automated rocket engine diagnostics. A qualitative model of a turbopump interpropellant seal system has been created. The qualitative model describes the effects of seal failures on the system steady-state behavior. This model is able to diagnose the failure of particular seals in the system based on anomalous temperature and pressure values. The anomalous values input to the qualitative model are generated using numerical simulations. Diagnostic test cases include both single and multiple seal failures.
Rocket engine diagnostics using qualitative modeling techniques
NASA Technical Reports Server (NTRS)
Binder, Michael; Maul, William; Meyer, Claudia; Sovie, Amy
1992-01-01
Researchers at NASA Lewis Research Center are presently developing qualitative modeling techniques for automated rocket engine diagnostics. A qualitative model of a turbopump interpropellant seal system was created. The qualitative model describes the effects of seal failures on the system steady state behavior. This model is able to diagnose the failure of particular seals in the system based on anomalous temperature and pressure values. The anomalous values input to the qualitative model are generated using numerical simulations. Diagnostic test cases include both single and multiple seal failures.
Kalil, Roberto S; Carpenter, Myra A; Ivanova, Anastasia; Gravens-Mueller, Lisa; John, Alin A; Weir, Matthew R; Pesavento, Todd; Bostom, Andrew G; Pfeffer, Marc A; Hunsicker, Lawrence G
2017-12-01
Elevated uric acid concentration is associated with higher rates of cardiovascular (CV) morbidity and mortality in the general population. It is not known whether hyperuricemia increases the risk for CV death or transplant failure in kidney transplant recipients. Post hoc cohort analysis of the FAVORIT Study, a randomized controlled trial that examined the effect of homocysteine-lowering vitamins on CV disease in kidney transplantation. Adult recipients of kidney transplants in the United States, Canada, or Brazil participating in the FAVORIT Study, with hyperhomocysteinemia, stable kidney function, and no known history of CV disease. Uric acid concentration. The primary end point was a composite of CV events. Secondary end points were all-cause mortality and transplant failure. Risk factors included in statistical models were age, sex, race, country, treatment assignment, smoking history, body mass index, presence of diabetes mellitus, history of CV disease, blood pressure, estimated glomerular filtration rate (eGFR), donor type, transplant vintage, lipid concentrations, albumin-creatinine ratio, and uric acid concentration. Cox proportional hazards models were fit to examine the association of uric acid concentration with study end points after risk adjustment. 3,512 of 4,110 FAVORIT participants with baseline uric acid concentrations were studied. Median follow-up was 3.9 (IQR, 3.0-5.3) years. 503 patients had a primary CV event, 401 died, and 287 had transplant failure. In unadjusted analyses, uric acid concentration was significantly related to each outcome. Uric acid concentration was also strongly associated with eGFR. The relationship between uric acid concentration and study end points was no longer significant in fully adjusted multivariable models (P=0.5 for CV events; P=0.09 for death, and P=0.1 for transplant failure). Unknown use of uric acid-lowering agents among study participants. Following kidney transplantation, uric acid concentrations are not independently associated with CV events, mortality, or transplant failure. The strong association between uric acid concentrations with traditional risk factors and eGFR is a possible explanation. Copyright © 2017 National Kidney Foundation, Inc. All rights reserved.