Sample records for single sample injection

  1. Nanoliter-Scale Oil-Air-Droplet Chip-Based Single Cell Proteomic Analysis.

    PubMed

    Li, Zi-Yi; Huang, Min; Wang, Xiu-Kun; Zhu, Ying; Li, Jin-Song; Wong, Catherine C L; Fang, Qun

    2018-04-17

    Single cell proteomic analysis provides crucial information on cellular heterogeneity in biological systems. Herein, we describe a nanoliter-scale oil-air-droplet (OAD) chip for achieving multistep complex sample pretreatment and injection for single cell proteomic analysis in the shotgun mode. By using miniaturized stationary droplet microreaction and manipulation techniques, our system allows all sample pretreatment and injection procedures to be performed in a nanoliter-scale droplet with minimum sample loss and a high sample injection efficiency (>99%), thus substantially increasing the analytical sensitivity for single cell samples. We applied the present system in the proteomic analysis of 100 ± 10, 50 ± 5, 10, and 1 HeLa cell(s), and protein IDs of 1360, 612, 192, and 51 were identified, respectively. The OAD chip-based system was further applied in single mouse oocyte analysis, with 355 protein IDs identified at the single oocyte level, which demonstrated its special advantages of high enrichment of sequence coverage, hydrophobic proteins, and enzymatic digestion efficiency over the traditional in-tube system.

  2. Further improvement of hydrostatic pressure sample injection for microchip electrophoresis.

    PubMed

    Luo, Yong; Zhang, Qingquan; Qin, Jianhua; Lin, Bingcheng

    2007-12-01

    Hydrostatic pressure sample injection method is able to minimize the number of electrodes needed for a microchip electrophoresis process; however, it neither can be applied for electrophoretic DNA sizing, nor can be implemented on the widely used single-cross microchip. This paper presents an injector design that makes the hydrostatic pressure sample injection method suitable for DNA sizing. By introducing an assistant channel into the normal double-cross injector, a rugged DNA sample plug suitable for sizing can be successfully formed within the cross area during the sample loading. This paper also demonstrates that the hydrostatic pressure sample injection can be performed in the single-cross microchip by controlling the radial position of the detection point in the separation channel. Rhodamine 123 and its derivative as model sample were successfully separated.

  3. Droplet-based microfluidic flow injection system with large-scale concentration gradient by a single nanoliter-scale injection for enzyme inhibition assay.

    PubMed

    Cai, Long-Fei; Zhu, Ying; Du, Guan-Sheng; Fang, Qun

    2012-01-03

    We described a microfluidic chip-based system capable of generating droplet array with a large scale concentration gradient by coupling flow injection gradient technique with droplet-based microfluidics. Multiple modules including sample injection, sample dispersion, gradient generation, droplet formation, mixing of sample and reagents, and online reaction within the droplets were integrated into the microchip. In the system, nanoliter-scale sample solution was automatically injected into the chip under valveless flow injection analysis mode. The sample zone was first dispersed in the microchannel to form a concentration gradient along the axial direction of the microchannel and then segmented into a linear array of droplets by immiscible oil phase. With the segmentation and protection of the oil phase, the concentration gradient profile of the sample was preserved in the droplet array with high fidelity. With a single injection of 16 nL of sample solution, an array of droplets with concentration gradient spanning 3-4 orders of magnitude could be generated. The present system was applied in the enzyme inhibition assay of β-galactosidase to preliminarily demonstrate its potential in high throughput drug screening. With a single injection of 16 nL of inhibitor solution, more than 240 in-droplet enzyme inhibition reactions with different inhibitor concentrations could be performed with an analysis time of 2.5 min. Compared with multiwell plate-based screening systems, the inhibitor consumption was reduced 1000-fold. © 2011 American Chemical Society

  4. Acupuncture injection for field amplified sample stacking and glass microchip-based capillary gel electrophoresis.

    PubMed

    Ha, Ji Won; Hahn, Jong Hoon

    2017-02-01

    Acupuncture sample injection is a simple method to deliver well-defined nanoliter-scale sample plugs in PDMS microfluidic channels. This acupuncture injection method in microchip CE has several advantages, including minimization of sample consumption, the capability of serial injections of different sample solutions into the same microchannel, and the capability of injecting sample plugs into any desired position of a microchannel. Herein, we demonstrate that the simple and cost-effective acupuncture sample injection method can be used for PDMS microchip-based field amplified sample stacking in the most simplified straight channel by applying a single potential. We achieved the increase in electropherogram signals for the case of sample stacking. Furthermore, we present that microchip CGE of ΦX174 DNA-HaeⅢ digest can be performed with the acupuncture injection method on a glass microchip while minimizing sample loss and voltage control hardware. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Electrokinetic focusing injection methods on microfluidic devices.

    PubMed

    Fu, Lung-Ming; Yang, Ruey-Jen; Lee, Gwo-Bin

    2003-04-15

    This paper presents an experimental and numerical investigation into electrokinetic focusing injection on microfluidic chips. The valving characteristics on microfluidic devices are controlled through appropriate manipulations of the electric potential strengths during the sample loading and dispensing steps. The present study also addresses the design and testing of various injection systems used to deliver a sample plug. A novel double-cross injection microfluidic chip is fabricated, which employs electrokinetic focusing to deliver sample plugs of variable volume. The proposed design combines several functions of traditional sample plug injection systems on a single microfluidic chip. The injection technique uses an unique sequence of loading steps with different electric potential distributions and magnitudes within the various channels to effectuate a virtual valve.

  6. Sample injection and electrophoretic separation on a simple laminated paper based analytical device.

    PubMed

    Xu, Chunxiu; Zhong, Minghua; Cai, Longfei; Zheng, Qingyu; Zhang, Xiaojun

    2016-02-01

    We described a strategy to perform multistep operations on a simple laminated paper-based separation device by using electrokinetic flow to manipulate the fluids. A laminated crossed-channel paper-based separation device was fabricated by cutting a filter paper sheet followed by lamination. Multiple function units including sample loading, sample injection, and electrophoretic separation were integrated on a single paper based analytical device for the first time, by applying potential at different reservoirs for sample, sample waste, buffer, and buffer waste. As a proof-of-concept demonstration, mixed sample solution containing carmine and sunset yellow were loaded in the sampling channel, and then injected into separation channel followed by electrophoretic separation, by adjusting the potentials applied at the four terminals of sampling and separation channel. The effects of buffer pH, buffer concentration, channel width, and separation time on resolution of electrophoretic separation were studied. This strategy may be used to perform multistep operations such as reagent dilution, sample injection, mixing, reaction, and separation on a single microfluidic paper based analytical device, which is very attractive for building micro total analysis systems on microfluidic paper based analytical devices. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Single-sample 99mTc-diethylenetriamine penta-acetate plasma clearance in advanced renal failure by the mean sojourn time approach.

    PubMed

    Gref, Margareta C; Karp, Kjell H

    2009-03-01

    The single-sample Tc-diethylenetriamine penta-acetate (DTPA) clearance method by Christensen and Groth is recommended by the Radionuclides in Nephrourology Committee on Renal Clearance for use in adults with an estimated glomerular filtration rate (GFR) > or = 30 ml/min. The purpose of this study was to test a new Tc-DTPA single-sample low clearance formula for GFR lesser than 30 ml/min. Twenty-one adult patients (29 investigations) were included. Reference clearance was calculated with both Cr-EDTA and Tc-DTPA according to Brøchner-Mortensen with samples drawn between 3 and 24 h. Single-sample clearance was calculated from a 24 h sample using the low clearance formula(Equation is included in full-text article.) C(t) is the activity of the tracer in the plasma sample t minutes after the injection and Q0 is the injected amount. ECV is the extracellular volume in ml defined as the distribution volume of the tracer. ECV is estimated from the body surface area as ECV=8116.6xbody surface area-28.2. The mean difference between reference and Tc-DTPA single-sample clearance was -0.5 ml/min (SD 1.0 ml/min) for Tc-DTPA and -0.8 ml/min (SD 1.2 ml/min) for Cr-EDTA as reference clearance. In adult patients it is possible, even with GFR lesser than 30 ml/min, to get an accurate determination of Tc-DTPA plasma clearance from a single sample using the mean sojourn time approach. The blood sample should be obtained about 24 h after injection of the GFR tracer.

  8. A comparison of four-sample slope-intercept and single-sample 51Cr-EDTA glomerular filtration rate measurements.

    PubMed

    Porter, Charlotte A; Bradley, Kevin M; McGowan, Daniel R

    2018-05-01

    The aim of this study was to verify, with a large dataset of 1394 Cr-EDTA glomerular filtration rate (GFR) studies, the equivalence of slope-intercept and single-sample GFR. Raw data from 1394 patient studies were used to calculate four-sample slope-intercept GFR in addition to four individual single-sample GFR values (blood samples taken at 90, 150, 210 and 270 min after injection). The percentage differences between the four-sample slope-intercept and each of the single-sample GFR values were calculated, to identify the optimum single-sample time point. Having identified the optimum time point, the percentage difference between the slope-intercept and optimal single-sample GFR was calculated across a range of GFR values to investigate whether there was a GFR value below which the two methodologies cannot be considered equivalent. It was found that the lowest percentage difference between slope-intercept and single-sample GFR was for the third blood sample, taken at 210 min after injection. The median percentage difference was 2.5% and only 6.9% of patient studies had a percentage difference greater than 10%. Above a GFR value of 30 ml/min/1.73 m, the median percentage difference between the slope-intercept and optimal single-sample GFR values was below 10%, and so it was concluded that, above this value, the two techniques are sufficiently equivalent. This study supports the recommendation of performing single-sample GFR measurements for GFRs greater than 30 ml/min/1.73 m.

  9. Multiplexed detection of nitrate and nitrite for capillary electrophoresis with an automated device for high injection efficiency.

    PubMed

    Gao, Leyi; Patterson, Eric E; Shippy, Scott A

    2006-02-01

    A simple automated nanoliter scale injection device which allows for reproducible 5 nL sample injections from samples with a volume of <1 microL is successfully used for conventional capillary electrophoresis (CE) and Hadamard transform (HT) CE detection. Two standard fused silica capillaries are assembled axially through the device to function as an injection and a separation capillary. Sample solution is supplied to the injection capillary using pressure controlled with a solenoid valve. Buffer solution flows gravimetrically by the junction of the injection and separation capillaries and is also gated with a solenoid valve. Plugs of sample are pushed into the space between the injection and separation capillaries for electrokinectic injection. To evaluate the performance of the injection device, several optimizations are performed including the influence of flow rates, the injected sample volume and the control of the buffer transverse flow on the overall sensitivity. The system was then applied to HT-CE-UV detection for the signal-to-noise ratio (S/N) improvement of the nitric oxide (NO) metabolites, nitrite and nitrate. In addition, signal averaging was performed to explore the possibility of greater sensitivity enhancements compared to single injections.

  10. Pharmacokinetic-pharmacodynamic study of subcutaneous injection of depot nandrolone decanoate using dried blood spots sampling coupled with ultrapressure liquid chromatography tandem mass spectrometry assays.

    PubMed

    Singh, Gurmeet K S; Turner, Leo; Desai, Reena; Jimenez, Mark; Handelsman, David J

    2014-07-01

    Testosterone (T) and nandrolone (N) esters require deep im injections by medical personnel but these often deposit injectate into sc fat so that more convenient sc self-administration may be feasible. To investigate the feasibility and pharmacology of sc injection of N decanoate in healthy men using dried blood spot (DBS) for frequent blood sampling without clinic visits. Healthy male volunteers received 100 mg N decanoate by a single sc injection. Finger-prick capillary blood was spotted onto filter paper before injection daily at home for 21 d and stored at room temperature. Venous whole blood was also spotted onto filter paper before and weekly for 3 wk after injection. DBS were extracted for assay of N and T by liquid chromatography tandem mass spectrometry in a single batch with serum concentrations estimated with adjustment for capillary blood sample volume and hematocrit to define peak (N) or nadir (T) time and concentration from individual daily measurements. Daily serum N peaked 2.50 ± 0.25 (SEM) ng/mL at a median (range) of 6 (4-13) days causing a reduction in serum T from 3.50 ± 0.57 ng/mL at baseline to a nadir of 0.38 ± 0.13 (SEM) ng/mL (89 ± 3% suppression) at a median (range) of 8 (5-16) days. Simultaneously sampled capillary, venous whole blood, and serum gave almost identical results for serum T and N. Finger-pricks and sc injections were well tolerated. This study demonstrates that A) DBS sampling with liquid chromatography mass spectrometry steroid analysis achieves frequent time sampling in the community without requiring clinic visits, venesection, or frozen serum storage, and B) androgen esters in an oil vehicle can be delivered effectively by sc injection, thus avoiding the need for medically supervised deep-im injections.

  11. Simulation of a Single-Element Lean-Direct Injection Combustor Using a Polyhedral Mesh Derived from Hanging-Node Elements

    NASA Technical Reports Server (NTRS)

    Wey, Thomas; Liu, Nan-Suey

    2013-01-01

    This paper summarizes the procedures of generating a polyhedral mesh derived from hanging-node elements as well as presents sample results from its application to the numerical solution of a single element lean direct injection (LDI) combustor using an open-source version of the National Combustion Code (NCC).

  12. Transfer of single dose of intravitreal injection of ranibizumab and bevacizumab into milk of sheep

    PubMed Central

    Cakmak Argun, Tugba; Yalcin Tok, Ozlem; Tok, Levent; Yilmaz, Gulsen; Meric Yilmaz, Fatma; Gunes, Alime; Argun, Mehmet; Butuner, Osman

    2017-01-01

    AIM To investigate whether single-dose intravitreal injections of bevacizumab and ranibizumab transfer into milk. METHODS This study included lactating 12 sheep and a single 3-month old suckling lamb of each sheep. Two groups consisting of 6 sheep and their lambs were constituted; the ranibizumab group and the bevacizumab group before the administration of intravitreal injections, blood and milk samples were obtained from all sheep and, following the injections, blood and milk samples of all sheep and blood samples of all lambs were collected at regular time points. Serum and milk concentrations of bevacizumab and ranibizumab were measured using an enzyme-linked immunosorbent assay (ELISA) kit. The limit of determination was 0.9 ng/mL for bevacizumab and 0.62 ng/mL for ranibizumab. RESULTS At 6h after intravitreal injections, bevacizumab concentration was above the limit of determination in the blood of all sheep. At 3wk, when the study was terminated, bevacizumab concentrations were high in 4 sheep. Even though bevacizumab concentrations in milk showed fluctuations, the drug transferred into the milk of all sheep at detectable concentrations. Ranibizumab drug concentrations in the blood and milk of sheep and those in the blood of lambs were below the limit of determination by the ELISA kit. CONCLUSION This sheep model study demonstrate that intravitreal injection of ranibizumab, which did not transfer into the milk of sheep and suckling lambs, is safer than bevacizumab during lactation period. PMID:28730108

  13. Accuracy of MRI-compatible contrast media injectors.

    PubMed

    Saake, M; Wuest, W; Becker, S; Uder, M; Janka, R

    2014-03-01

    To analyze the exactness of MRI-compatible contrast media (CM) injectors in an experimental setup and clinical use. Ejected fluid volumes and amounts of CM were quantified for single and double piston injections. The focus was on small volumes, as used in pediatric examination and test-bolus measurements. Samples were collected before and after clinical MRI scans and amounts of CM were measured. For single piston injections the volume differences were minimal (mean difference 0.01  ml). For double piston injections the volume of the first injection was decreased (mean 20.74  ml, target 21.00  ml, p < 0.01). After a position change of the Y-piece of the injection system, the amount of CM differed significantly from the target value (mean 1.23  mmol and 0.83  mmol at 1  ml/s flow rate, target 1.00  mmol, p < 0.01), independently of the wait time. The clinical samples confirmed these findings. The pistons of modern CM injectors work exactly. However, for small CM volumes the injected amount of CM can differ significantly from the target value in both directions. Influence factors are an incomplete elimination of air and exchange processes between the CM and saline chaser in the injection system. • In MRI examinations of children and test-bolus measurements, small amounts of CM are used. • The accuracy of single piston injections is high. • In double piston injections the injected amount of CM can differ significantly from the target value. © Georg Thieme Verlag KG Stuttgart · New York.

  14. Single column comprehensive analysis of pharmaceutical preparations using dual-injection mixed-mode (ion-exchange and reversed-phase) and hydrophilic interaction liquid chromatography.

    PubMed

    Kazarian, Artaches A; Taylor, Mark R; Haddad, Paul R; Nesterenko, Pavel N; Paull, Brett

    2013-12-01

    The comprehensive separation and detection of hydrophobic and hydrophilic active pharmaceutical ingredients (APIs), their counter-ions (organic, inorganic) and excipients, using a single mixed-mode chromatographic column, and a dual injection approach is presented. Using a mixed-mode Thermo Fisher Acclaim Trinity P1 column, APIs, their counter-ions and possible degradants were first separated using a combination of anion-exchange, cation-exchange and hydrophobic interactions, using a mobile phase consisting of a dual organic modifier/salt concentration gradient. A complementary method was also developed using the same column for the separation of hydrophilic bulk excipients, using hydrophilic interaction liquid chromatography (HILIC) under high organic solvent mobile phase conditions. These two methods were then combined within a single gradient run using dual sample injection, with the first injection at the start of the applied gradient (mixed-mode retention of solutes), followed by a second sample injection at the end of the gradient (HILIC retention of solutes). Detection using both ultraviolet absorbance and refractive index enabled the sensitive detection of APIs and UV-absorbing counter-ions, together with quantitative determination of bulk excipients. The developed approach was applied successfully to the analysis of a dry powder inhalers (Flixotide(®), Spiriva(®)), enabling comprehensive quantification of all APIs and excipients in the sample. Copyright © 2013 Elsevier B.V. All rights reserved.

  15. Electrokinetic Sample Preconcentration and Hydrodynamic Sample Injection for Microchip Electrophoresis Using a Pneumatic Microvalve

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cong, Yongzheng; Katipamula, Shanta; Geng, Tao

    2016-02-01

    A microfluidic platform was developed to perform online electrokinetic sample preconcentration and rapid hydrodynamic sample injection for electrophoresis using a single microvalve. The PDMS microchip consists of a separation channel, a side channel for sample introduction, and a control channel which is used as a pneumatic microvalve aligned at the intersection of the two flow channels. The closed microvalve, created by multilayer soft lithography, can serve as a preconcentrator under an applied electric potential, enabling current to pass through while blocking bulk flow. Once analytes are concentrated, the valve is briefly opened and the stacked sample is pressure injected intomore » the separation channel for electrophoretic separation. Fluorescently labeled peptides were enriched by a factor of ~450 in 230 s. The performance of the platform was validated by the online preconcentration, injection and electrophoretic separation of fluorescently labeled peptides. This method enables both rapid analyte concentration and controlled injection volume for high sensitivity, high resolution capillary electrophoresis.« less

  16. Electrokinetic sample preconcentration and hydrodynamic sample injection for microchip electrophoresis using a pneumatic microvalve.

    PubMed

    Cong, Yongzheng; Katipamula, Shanta; Geng, Tao; Prost, Spencer A; Tang, Keqi; Kelly, Ryan T

    2016-02-01

    A microfluidic platform was developed to perform online electrokinetic sample preconcentration and rapid hydrodynamic sample injection for zone electrophoresis using a single microvalve. The polydimethylsiloxane microchip comprises a separation channel, a side channel for sample introduction, and a control channel which is used as a pneumatic microvalve aligned at the intersection of the two flow channels. The closed microvalve, created by multilayer soft lithography, serves as a nanochannel preconcentrator under an applied electric potential, enabling current to pass through while preventing bulk flow. Once analytes are concentrated, the valve is briefly opened and the stacked sample is pressure injected into the separation channel for electrophoretic separation. Fluorescently labeled peptides were enriched by a factor of ∼450 in 230 s. This method enables both rapid analyte concentration and controlled injection volume for high sensitivity, high-resolution CE. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Stability of methadone hydrochloride in 0.9% sodium chloride injection in single-dose plastic containers.

    PubMed

    Denson, D D; Crews, J C; Grummich, K W; Stirm, E J; Sue, C A

    1991-03-01

    The stability of methadone hydrochloride in 0.9% sodium chloride injection in flexible polyvinyl chloride containers was studied. Commercially available methadone hydrochloride 20 mg/mL and 25-mL single-dose bags of 0.9% sodium chloride injection were used. Six samples each were prepared at methadone hydrochloride concentrations of 1, 2, and 5 mg/mL. The solutions were stored at room temperature and were not protected from light. Immediately after preparation and after two, three, and four weeks of storage, each of the 18 samples was divided into three aliquots, each of which was analyzed in duplicate for methadone hydrochloride concentration by gas chromatography. There was less than 10% change in methadone hydrochloride concentration in any sample throughout the four-week study period. Methadone hydrochloride at concentrations of 1, 2, and 5 mg/mL prepared in commercially available flexible polyvinyl chloride containers of 0.9% sodium chloride injection and stored at room temperature without deliberate protection from light is stable for at least four weeks.

  18. Novel approaches to analysis by flow injection gradient titration.

    PubMed

    Wójtowicz, Marzena; Kozak, Joanna; Kościelniak, Paweł

    2007-09-26

    Two novel procedures for flow injection gradient titration with the use of a single stock standard solution are proposed. In the multi-point single-line (MP-SL) method the calibration graph is constructed on the basis of a set of standard solutions, which are generated in a standard reservoir and subsequently injected into the titrant. According to the single-point multi-line (SP-ML) procedure the standard solution and a sample are injected into the titrant stream from four loops of different capacities, hence four calibration graphs are able to be constructed and the analytical result is calculated on the basis of a generalized slope of these graphs. Both approaches have been tested on the example of spectrophotometric acid-base titration of hydrochloric and acetic acids with using bromothymol blue and phenolphthalein as indicators, respectively, and sodium hydroxide as a titrant. Under optimized experimental conditions the analytical results of precision less than 1.8 and 2.5% (RSD) and of accuracy less than 3.0 and 5.4% (relative error (RE)) were obtained for MP-SL and SP-ML procedures, respectively, in ranges of 0.0031-0.0631 mol L(-1) for samples of hydrochloric acid and of 0.1680-1.7600 mol L(-1) for samples of acetic acid. The feasibility of both methods was illustrated by applying them to the total acidity determination in vinegar samples with precision lower than 0.5 and 2.9% (RSD) for MP-SL and SP-ML procedures, respectively.

  19. Synovial fluid bupivacaine concentrations following single intra-articular injection in normal and osteoarthritic canine stifles.

    PubMed

    Barry, S L; Martinez, S A; Davies, N M; Remsberg, C M; Sayre, C L; Bachelez, A

    2015-02-01

    Intra-articular bupivacaine helps alleviate pain in animals receiving joint surgery, but its use has become controversial as ex vivo studies have illuminated the potential for chondrotoxicity. Such studies typically involve cell cultures incubated in solutions containing high bupivacaine concentrations for long durations. The aim of this study was to measure the actual synovial fluid bupivacaine concentrations after intra-articular injection. Eight healthy beagles with normal stifles and 22 large and giant-breed dogs with stifle osteoarthritis (OA) were treated with a single intra-articular injection of bupivacaine (1 mg/kg) into a stifle. Joint fluid samples were taken from the treated stifle immediately after injection and 30 min after injection and analyzed for bupivacaine concentrations. Immediately after injection, the median bupivacaine concentrations in normal and OA stifles were 3.6 and 2.5 mg/mL, respectively. Thirty minutes after injection, bupivacaine concentrations in normal and OA stifles were 0.4 and 0.6 mg/mL, respectively. These results provide insight into the pharmacokinetics of bupivacaine after injection into a joint. Given its immediate dilution and rapid drop in synovial fluid concentration, bupivacaine is unlikely to damage chondrocytes when administered as a single intra-articular injection. © 2014 John Wiley & Sons Ltd.

  20. Large spin accumulation and crystallographic dependence of spin transport in single crystal gallium nitride nanowires

    PubMed Central

    Park, Tae-Eon; Park, Youn Ho; Lee, Jong-Min; Kim, Sung Wook; Park, Hee Gyum; Min, Byoung-Chul; Kim, Hyung-jun; Koo, Hyun Cheol; Choi, Heon-Jin; Han, Suk Hee; Johnson, Mark; Chang, Joonyeon

    2017-01-01

    Semiconductor spintronics is an alternative to conventional electronics that offers devices with high performance, low power and multiple functionality. Although a large number of devices with mesoscopic dimensions have been successfully demonstrated at low temperatures for decades, room-temperature operation still needs to go further. Here we study spin injection in single-crystal gallium nitride nanowires and report robust spin accumulation at room temperature with enhanced spin injection polarization of 9%. A large Overhauser coupling between the electron spin accumulation and the lattice nuclei is observed. Finally, our single-crystal gallium nitride samples have a trigonal cross-section defined by the (001), () and () planes. Using the Hanle effect, we show that the spin accumulation is significantly different for injection across the (001) and () (or ()) planes. This provides a technique for increasing room temperature spin injection in mesoscopic systems. PMID:28569767

  1. The 15N-leucine single-injection method allows for determining endogenous losses and true digestibility of amino acids in cecectomized roosters.

    PubMed

    Hu, Rujiu; Li, Jing; Soomro, Rab Nawaz; Wang, Fei; Feng, Yan; Yang, Xiaojun; Yao, Junhu

    2017-01-01

    This study was conducted to assess the influence of dietary protein content in poultry when using the 15N-leucine single-injection method to determine endogenous amino acid losses (EAALs) in poultry. Forty-eight cecectomized roosters (2.39 ± 0.23 kg) were randomly allocated to eight dietary treatments containing protein levels of 0, 3%, 6%, 9%, 12%, 15%, 18% and 21%. Each bird was precisely fed an experimental diet of 25 g/kg of body weight. After feeding, all roosters were subcutaneously injected with a 15N-leucine solution at a dose of 20 mg/kg of body weight. Blood was sampled 23 h after the injection, and excreta samples were continuously collected during the course of the 48-h experiment. The ratio of 15N-enrichment of leucine in crude mucin to free leucine in plasma ranged from 0.664 to 0.763 and remained relatively consistent (P > 0.05) across all treatments. The amino acid (AA) profiles of total endogenous AAs, except isoleucine, alanine, aspartic acid, cysteine, proline and serine, were not influenced (P > 0.05) by dietary protein contents. The predominant endogenous AAs in the excreta were glutamic acid, aspartic acid, threonine, serine and proline. The order of the relative proportions of these predominant AAs also remained relatively constant (P > 0.05). The endogenous losses of total AAs determined with the 15N-leucine single-injection method increased curvilinearly with the dietary protein contents. The true digestibility of most AAs and total AAs was independent of their respective dietary protein levels. Collectively, the 15N-leucine single-injection method is appropriate for determining EAALs and the true digestibility of AAs in poultry fed varying levels of protein-containing ingredients.

  2. The 15N-leucine single-injection method allows for determining endogenous losses and true digestibility of amino acids in cecectomized roosters

    PubMed Central

    Hu, Rujiu; Li, Jing; Soomro, Rab Nawaz; Wang, Fei; Feng, Yan; Yang, Xiaojun

    2017-01-01

    This study was conducted to assess the influence of dietary protein content in poultry when using the 15N-leucine single-injection method to determine endogenous amino acid losses (EAALs) in poultry. Forty-eight cecectomized roosters (2.39 ± 0.23 kg) were randomly allocated to eight dietary treatments containing protein levels of 0, 3%, 6%, 9%, 12%, 15%, 18% and 21%. Each bird was precisely fed an experimental diet of 25 g/kg of body weight. After feeding, all roosters were subcutaneously injected with a 15N-leucine solution at a dose of 20 mg/kg of body weight. Blood was sampled 23 h after the injection, and excreta samples were continuously collected during the course of the 48-h experiment. The ratio of 15N-enrichment of leucine in crude mucin to free leucine in plasma ranged from 0.664 to 0.763 and remained relatively consistent (P > 0.05) across all treatments. The amino acid (AA) profiles of total endogenous AAs, except isoleucine, alanine, aspartic acid, cysteine, proline and serine, were not influenced (P > 0.05) by dietary protein contents. The predominant endogenous AAs in the excreta were glutamic acid, aspartic acid, threonine, serine and proline. The order of the relative proportions of these predominant AAs also remained relatively constant (P > 0.05). The endogenous losses of total AAs determined with the 15N-leucine single-injection method increased curvilinearly with the dietary protein contents. The true digestibility of most AAs and total AAs was independent of their respective dietary protein levels. Collectively, the 15N-leucine single-injection method is appropriate for determining EAALs and the true digestibility of AAs in poultry fed varying levels of protein-containing ingredients. PMID:29166671

  3. Investigation of modulation parameters in multiplexing gas chromatography.

    PubMed

    Trapp, Oliver

    2010-10-22

    Combination of information technology and separation sciences opens a new avenue to achieve high sample throughputs and therefore is of great interest to bypass bottlenecks in catalyst screening of parallelized reactors or using multitier well plates in reaction optimization. Multiplexing gas chromatography utilizes pseudo-random injection sequences derived from Hadamard matrices to perform rapid sample injections which gives a convoluted chromatogram containing the information of a single sample or of several samples with similar analyte composition. The conventional chromatogram is obtained by application of the Hadamard transform using the known injection sequence or in case of several samples an averaged transformed chromatogram is obtained which can be used in a Gauss-Jordan deconvolution procedure to obtain all single chromatograms of the individual samples. The performance of such a system depends on the modulation precision and on the parameters, e.g. the sequence length and modulation interval. Here we demonstrate the effects of the sequence length and modulation interval on the deconvoluted chromatogram, peak shapes and peak integration for sequences between 9-bit (511 elements) and 13-bit (8191 elements) and modulation intervals Δt between 5 s and 500 ms using a mixture of five components. It could be demonstrated that even for high-speed modulation at time intervals of 500 ms the chromatographic information is very well preserved and that the separation efficiency can be improved by very narrow sample injections. Furthermore this study shows that the relative peak areas in multiplexed chromatograms do not deviate from conventionally recorded chromatograms. Copyright © 2010 Elsevier B.V. All rights reserved.

  4. Time-Bin-Encoded Boson Sampling with a Single-Photon Device.

    PubMed

    He, Yu; Ding, X; Su, Z-E; Huang, H-L; Qin, J; Wang, C; Unsleber, S; Chen, C; Wang, H; He, Y-M; Wang, X-L; Zhang, W-J; Chen, S-J; Schneider, C; Kamp, M; You, L-X; Wang, Z; Höfling, S; Lu, Chao-Yang; Pan, Jian-Wei

    2017-05-12

    Boson sampling is a problem strongly believed to be intractable for classical computers, but can be naturally solved on a specialized photonic quantum simulator. Here, we implement the first time-bin-encoded boson sampling using a highly indistinguishable (∼94%) single-photon source based on a single quantum-dot-micropillar device. The protocol requires only one single-photon source, two detectors, and a loop-based interferometer for an arbitrary number of photons. The single-photon pulse train is time-bin encoded and deterministically injected into an electrically programmable multimode network. The observed three- and four-photon boson sampling rates are 18.8 and 0.2 Hz, respectively, which are more than 100 times faster than previous experiments based on parametric down-conversion.

  5. GSK1265744 pharmacokinetics in plasma and tissue after single-dose long-acting injectable administration in healthy subjects.

    PubMed

    Spreen, William; Ford, Susan L; Chen, Shuguang; Wilfret, David; Margolis, David; Gould, Elizabeth; Piscitelli, Stephen

    2014-12-15

    GSK1265744 (744) is an HIV-1 integrase inhibitor in clinical development as a long-acting (LA) injectable formulation. This study evaluated plasma and tissue pharmacokinetics after single-dose administration of 744 LA administered by intramuscular (IM) or subcutaneous injections. This was a phase I, open-label, 9-cohort, parallel study of 744 in healthy subjects. 744 was administered as a 200 mg/mL nanosuspension at doses of 100-800 mg IM and 100-400 mg subcutaneous. Eight (6 active and 2 placebo) male and female subjects participated in each of the first 7 cohorts. All 8 subjects, 4 males and 4 females, received active 744 LA in cohorts 8 and 9 and underwent rectal and cervicovaginal tissue sampling, respectively. Plasma pharmacokinetic sampling was performed for a minimum of 12 weeks or until 744 concentrations were ≤0.1 μg/mL. Rectal and cervicovaginal tissue biopsies were performed at weeks 2 and 8 (cohort 8) and weeks 4 and 12 (cohort 9). 744 LA was generally safe and well tolerated after single injections. A majority of subjects reported injection site reactions, all graded as mild in intensity. Plasma concentration-time profiles were prolonged with measureable concentrations up to 52 weeks after dosing. 744 LA 800 mg IM achieved mean concentrations above protein adjusted-IC90 for approximately 16 weeks. Rectal and cervicovaginal tissue concentrations ranged from <8% to 28% of corresponding plasma concentrations. These data suggest 744 LA injection has potential application as a monthly or less frequent HIV treatment or prevention agent.

  6. Comparison of Flow Injection MS, NMR, and DNA Sequencing: Methods for Identification and Authentication of Black Cohosh (Actaea racemosa)

    USDA-ARS?s Scientific Manuscript database

    Flow injection mass spectrometry (FIMS) and proton nuclear magnetic resonance spectrometry (1H-NMR), two metabolic fingerprinting methods, and DNA sequencing were used to identify and authenticate Actaea species. Initially, samples of Actaea racemosa L. from a single source were distinguished from ...

  7. Simulation of a Single-Element Lean-Direct Injection Combustor Using Arbitrary Polyhedral Mesh

    NASA Technical Reports Server (NTRS)

    Wey, Thomas; Liu, Nan-Suey

    2012-01-01

    This paper summarizes procedures of generating the arbitrary polyhedral mesh as well as presents sample results from its application to the numerical solution of a single-element LDI combustor using a preliminary version of the new OpenNCC.

  8. Simultaneous determination of choline and acetylcholine based on a trienzyme chemiluminometric biosensor in a single line flow injection system.

    PubMed

    Kiba, Nobutoshi; Ito, Seiji; Tachibana, Masaki; Tani, Kazue; Koizumi, Hitoshi

    2003-12-01

    A detector for the simultaneous determination of choline (Ch) and acetylcholine (ACh) based on a sensitive trienzyme chemiluminometric biosensor in a single line flow injection (FI) system is described. Immobilized choline oxidase (ChOx), immobilized peroxidase (POx), immobilized acetylcholinesterase, and coimmobilized ChOx/POx were packed, in turn, in a transparent ETFE tube (1 mm i.d., 75 cm) and the tube was placed in front of a photomultipier tube as a flow cell. Two-peak response was obtained by one injection of the sample solution. The first and second peaks were dependent on the concentrations of Ch and ACh, respectively. The influence of some experimental parameters such as flow rate, amounts of immobilized enzymes on the behavior of the sensor was studied in order to optimize the sensitivity, sample throughput and resolution. Calibration curves were linear at 1 - 1000 nM for Ch and 3 - 3000 nM for ACh. The sample throughput was 25/h without carryover. The FI system was applied to the simultaneous determination of Ch and ACh in rabbit brain tissue homogenates.

  9. Crack injection in silver gold alloys

    NASA Astrophysics Data System (ADS)

    Chen, Xiying

    Stress corrosion cracking (SCC) is a materials degradation phenomena resulting from a combination of stress and a corrosive environment. Among the alphabet soup of proposed mechanism of SCC the most important are film-rupture, film-induced cleavage and hydrogen embrittlement. This work examines various aspects of film-induced cleavage in gold alloys for which the operation of hydrogen embrittlement processes can be strictly ruled out on thermodynamic grounds. This is so because in such alloys SCC occurs under electrochemical conditions within which water is stable to hydrogen gas evolution. The alloy system examined in this work is AgAu since the corrosion processes in this system occur by a dealloying mechanism that results in the formation of nanoporous gold. The physics behind the dealloying process as well as the resulting formation of nanoporous gold is today well understood. Two important aspects of the film-induced cleavage mechanism are examined in this work: dynamic fracture in monolithic nanoporous gold and crack injection. In crack injection there is a finite thickness dealloyed layer formed on a AgAu alloy sample and the question of whether or not a crack that nucleates within this layer can travel for some finite distance into the un-corroded parent phase alloy is addressed. Dynamic fracture tests were performed on single edge-notched monolithic nanoporous gold samples as well as "infinite strip" sample configurations for which the stress intensity remains constant over a significant portion of the crack length. High-speed photography was used to measure the crack velocity. In the dynamic fracture experiments cracks were observed to travel at speeds as large as 270 m/s corresponding to about 68% of the Raleigh wave velocity. Crack injection experiments were performed on single crystal Ag77Au23, polycrystalline Ag72Au28 and pure gold, all of which had thin nanoporous gold layers on the surface of samples. Through-thickness fracture was seen in both the single crystal and polycrystalline samples and there was an indication of ~ 1 mum injected cracks into pure gold. These results have important implications for the operation of the film-induced cleavage mechanism and represent a first step in the development of a fundamental model of SCC.

  10. Characterization of uveitis induced by use of a single intravitreal injection of bacterial lipopolysaccharide in cats.

    PubMed

    Del Sole, María J; Sande, Pablo H; Felipe, Antonio E; Fernandez, Diego C; Keller Sarmiento, María I; Aba, Marcelo A; Rosenstein, Ruth E

    2008-11-01

    To investigate the use of a single intravitreal injection of bacterial lipopolysaccharide (LPS) to experimentally induce uveitis in cats. 7 young male European shorthair cats that were considered physically and ophthalmologically healthy. In each cat, LPS was injected intravitreally into 1 eye; the contralateral eye was injected with the preparation vehicle. During a period of 45 days, both eyes were evaluated by means of clinical evaluation; assessment of the integrity of the blood-aqueous humor barrier (determined via measurement of protein concentration and cell content in samples of aqueous humor); functional analysis (via electroretinography); and following euthanasia, histologic examination of the retinas. In LPS-treated eyes, several clinical signs were observed until day 45 after injection. Compared with vehicle-treated eyes, intraocular pressure was significantly lower and protein concentration and the number of infiltrating cells were significantly higher in LPS-treated eyes. Mean amplitudes of scotopic electroretinographic a- and b-waves were significantly reduced in eyes injected with LPS, compared with findings in eyes injected with vehicle. At 45 days after injection, LPS-induced alterations in photoreceptors and the middle portion of the retina were detected histologically. Results indicated that a single intravitreal injection of LPS in eyes of cats induced clinical, biochemical, functional, and histologic changes that were consistent with the main features of naturally occurring uveitis. This technique may be a useful tool in the investigation of new treatment strategies for uveitis in cats.

  11. Transient effects of methyltestosterone injection on different reproductive parameters of the hermaphrodite fish Kryptolebias marmoratus.

    PubMed

    Park, Chang-Beom; Soyano, Kiyoshi; Kiros, Solomon; Kitamura, Tomokazu; Minamiyama, Mizuhiko; Suzuki, Yutaka

    2013-09-01

    To elucidate the action mechanism of environmental androgenic chemicals on fish reproductive activity by transient stimulation in heavily polluted areas, individuals of the hermaphrodite fish Kryptolebias marmoratus were injected once with six concentrations of methyltestosterone (MT) (0.1, 1, 5, 10, 50, and 100 μg/g BW) intraperitoneally. The fish were sampled at intervals of 7, 15, and 30 days after a single injection. At 7 days after injection, mature oocytes were not observed in the MT-exposed groups except for the group exposed to 0.1 μg MT, while testicular development was not remarkably different between any of the groups. Also, at 7 days after injection, hepatic estrogen receptor α (ERα) and vitellogenin (VTG) mRNA abundance decreased significantly in the MT-exposed groups despite no significant difference in plasma 17β-estradiol (E2) levels between any of the groups. This significant difference in VTG mRNA between the control and the MT-exposed groups persisted until 30 days after injection, although ERα mRNA abundance was not statistically different between any groups at 30 days after injection. Our results clearly show that a single injection of MT inhibits ovarian development rather than testicular development in the hermaphroditic gonad of K. marmoratus. Furthermore, our results demonstrate that a single injection of MT interfered with hepatic VTG mRNA synthesis mediated by the suppression of hepatic ERα mRNA transcription.

  12. Single-sample method for the estimation of glomerular filtration rate in children

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tauxe, W.N.; Bagchi, A.; Tepe, P.G.

    1987-03-01

    A method for the determination of the glomerular filtration rate (GFR) in children which involves the use of a single-plasma sample (SPS) after the injection of a radioactive indicator such as radioiodine labeled diatrizoate (Hypaque) has been developed. This is analogous to previously published SPS techniques of effective renal plasma flow (ERPF) in adults and children and GFR SPS techniques in adults. As a reference standard, GFR has been calculated from compartment analysis of injected radiopharmaceuticals (Sapirstein Method). Theoretical volumes of distribution were calculated at various times after injection (Vt) by dividing the total injected counts (I) by the plasmamore » concentration (Ct) expressed in liters, determined by counting an aliquot of plasma in a well type scintillation counter. Errors of predicting GFR from the various Vt values were determined as the standard error of estimate (Sy.x) in ml/min. They were found to be relatively high early after injection and to fall to a nadir of 3.9 ml/min at 91 min. The Sy.x Vt relationship was examined in linear, quadratic, and exponential form, but the simpler linear relationship was found to yield the lowest error. Other data calculated from the compartment analysis of the reference plasma disappearance curves are presented, but at this time have apparently little clinical relevance.« less

  13. Pharmacokinetics of enrofloxacin and ciprofloxacin in Atlantic horseshoe crabs (Limulus polyphemus) after single injection.

    PubMed

    Kirby, A; Lewbart, G A; Hancock-Ronemus, A; Papich, M G

    2018-04-01

    The pharmacokinetics of enrofloxacin and the metabolite ciprofloxacin were studied in horseshoe crabs after a single injection of 5 mg/kg. Twelve Atlantic horseshoe crabs (Limulus polyphemus) of undetermined age were injected with enrofloxacin into the dorsal cardiac sinus. Hemolymph samples were collected by syringe and needle at regular intervals for 120 hr. Samples were analyzed by high-pressure liquid chromatography and compartmental analysis performed on the results. Following injection, the elimination half-life (T½), peak concentration, area under the curve (AUC), and volume of distribution (VD) for enrofloxacin were 27.9 (29.13) hr, 8.98 (18.09) μg/ml, 367.38 (35.41) hr μg/ml, and 0.575 (20.48) L/kg, respectively (mean value, CV%). For ciprofloxacin, the elimination T½, peak concentration, and AUC were 61.36 (34.55) hr, 2.34 (24.11) μg/ml, and 304.46 (24.69) μg hr/ml. In these animals, the ciprofloxacin concentrations comprised an average of 45.8% of the total fluoroquinolone concentrations, which is substantial compared to other marine invertebrates. The total AUC produced (sum of enrofloxacin and ciprofloxacin) was 682.69 ± 180.61 μg hr/ml. Concentrations that were achieved after a single dose of 5 mg/kg horseshoe crabs were sufficient to treat bacteria susceptible to enrofloxacin and ciprofloxacin. © 2017 John Wiley & Sons Ltd.

  14. Marker retention in the cochlea following injections through the round window membrane

    PubMed Central

    Salt, Alec N.; Sirjani, Davud B.; Hartsock, Jared J.; Gill, Ruth M.; Plontke, Stefan K.

    2007-01-01

    Local delivery of drugs to the inner ear is increasingly being used in both clinical and experimental studies. Although direct injection of drugs into perilymph appears to be the most promising way of administering drugs quantitatively, no studies have yet demonstrated the pharmacokinetics in perilymph following direct injections. In this study, we have investigated the retention of substance in perilymph following a single injection into the basal turn of scala tympani (ST). The substance injected was a marker, trimethylphenylammonium (TMPA) that can be detected in low concentrations with ion-selective microelectrodes. Perilymph pharmacokinetics of TMPA was assessed using sequential apical sampling to obtain perilymph for analysis. The amount of TMPA retained in perilymph was compared for different injection and sampling protocols. TMPA concentrations measured in fluid samples were close to those predicted by simulations when the injection pipette was sealed into the bony wall of ST but were systematically lower when the injection pipette was inserted through the round window membrane (RWM). In the latter condition it was estimated that over 60% of the injected TMPA was lost due to leakage of perilymph around the injection pipette at a rate estimated to be 0.09 μL/min. The effects of leakage during and after injections through the RWM were dramatically reduced when the round window niche was filled with 1% sodium hyaluronate gel before penetrating the RWM with the injection pipette. The findings demonstrate that in order to perform quantitative drug injections into perilymph, even small rates of fluid leakage at the injection site must be controlled. PMID:17662546

  15. Polymeric microchip for the simultaneous determination of anions and cations by hydrodynamic injection using a dual-channel sequential injection microchip electrophoresis system.

    PubMed

    Gaudry, Adam J; Nai, Yi Heng; Guijt, Rosanne M; Breadmore, Michael C

    2014-04-01

    A dual-channel sequential injection microchip capillary electrophoresis system with pressure-driven injection is demonstrated for simultaneous separations of anions and cations from a single sample. The poly(methyl methacrylate) (PMMA) microchips feature integral in-plane contactless conductivity detection electrodes. A novel, hydrodynamic "split-injection" method utilizes background electrolyte (BGE) sheathing to gate the sample flows, while control over the injection volume is achieved by balancing hydrodynamic resistances using external hydrodynamic resistors. Injection is realized by a unique flow-through interface, allowing for automated, continuous sampling for sequential injection analysis by microchip electrophoresis. The developed system was very robust, with individual microchips used for up to 2000 analyses with lifetimes limited by irreversible blockages of the microchannels. The unique dual-channel geometry was demonstrated by the simultaneous separation of three cations and three anions in individual microchannels in under 40 s with limits of detection (LODs) ranging from 1.5 to 24 μM. From a series of 100 sequential injections the %RSDs were determined for every fifth run, resulting in %RSDs for migration times that ranged from 0.3 to 0.7 (n = 20) and 2.3 to 4.5 for peak area (n = 20). This system offers low LODs and a high degree of reproducibility and robustness while the hydrodynamic injection eliminates electrokinetic bias during injection, making it attractive for a wide range of rapid, sensitive, and quantitative online analytical applications.

  16. Bubble-free on-chip continuous-flow polymerase chain reaction: concept and application.

    PubMed

    Wu, Wenming; Kang, Kyung-Tae; Lee, Nae Yoon

    2011-06-07

    Bubble formation inside a microscale channel is a significant problem in general microfluidic experiments. The problem becomes especially crucial when performing a polymerase chain reaction (PCR) on a chip which is subject to repetitive temperature changes. In this paper, we propose a bubble-free sample injection scheme applicable for continuous-flow PCR inside a glass/PDMS hybrid microfluidic chip, and attempt to provide a theoretical basis concerning bubble formation and elimination. Highly viscous paraffin oil plugs are employed in both the anterior and posterior ends of a sample plug, completely encapsulating the sample and eliminating possible nucleation sites for bubbles. In this way, internal channel pressure is increased, and vaporization of the sample is prevented, suppressing bubble formation. Use of an oil plug in the posterior end of the sample plug aids in maintaining a stable flow of a sample at a constant rate inside a heated microchannel throughout the entire reaction, as compared to using an air plug. By adopting the proposed sample injection scheme, we demonstrate various practical applications. On-chip continuous-flow PCR is performed employing genomic DNA extracted from a clinical single hair root sample, and its D1S80 locus is successfully amplified. Also, chip reusability is assessed using a plasmid vector. A single chip is used up to 10 times repeatedly without being destroyed, maintaining almost equal intensities of the resulting amplicons after each run, ensuring the reliability and reproducibility of the proposed sample injection scheme. In addition, the use of a commercially-available and highly cost-effective hot plate as a potential candidate for the heating source is investigated.

  17. Residue depletion of tilmicosin in cattle after subcutaneous administration.

    PubMed

    Jiang, Haiyang; Ding, Shuangyang; Li, Jiancheng; An, Dianjin; Li, Cun; Shen, Jianzhong

    2006-07-12

    A study of tissue residue depletion of tilmicosin in cattle was conducted after a single subcutaneous injection at the therapeutic level of 10 mg per kg body weight. Eighteen cross cattle were treated with the tilmicosin oil formulation (30%). Three treated animals (two males and one female) were selected randomly to be scarified at 1, 7, 14, 28, and 35 days withdrawal after injection. Samples of the injection site and of muscle, liver, kidney, and fat were collected. Tilmicosin residue concentrations were determined using a high-performance liquid chromatography (HPLC) method with a UV detector at 290 nm. Using a statistical method recommended by the Committee for Veterinary Medical Products of European Medical Evaluation Agency, the withdrawal time of 34 days was established when all tissue residues except samples in the injection site were below the accepted maximum residue limits.

  18. Computational Fluid Dynamics Analysis of the Venturi Dustiness Tester

    PubMed Central

    Dubey, Prahit; Ghia, Urmila; Turkevich, Leonid A.

    2017-01-01

    Dustiness quantifies the propensity of a finely divided solid to be aerosolized by a prescribed mechanical stimulus. Dustiness is relevant wherever powders are mixed, transferred or handled, and is important in the control of hazardous exposures and the prevention of dust explosions and product loss. Limited quantities of active pharmaceutical powders available for testing led to the development (at University of North Carolina) of a Venturi-driven dustiness tester. The powder is turbulently injected at high speed (Re ~ 2 × 104) into a glass chamber; the aerosol is then gently sampled (Re ~ 2 × 103) through two filters located at the top of the chamber; the dustiness index is the ratio of sampled to injected mass of powder. Injection is activated by suction at an Extraction Port at the top of the chamber; loss of powder during injection compromises the sampled dustiness. The present work analyzes the flow inside the Venturi Dustiness Tester, using an Unsteady Reynolds-Averaged Navier-Stokes formulation with the k-ω Shear Stress Transport turbulence model. The simulation considers single-phase flow, valid for small particles (Stokes number Stk <1). Results show that ~ 24% of fluid-tracers escape the tester before the Sampling Phase begins. Dispersion of the powder during the Injection Phase results in a uniform aerosol inside the tester, even for inhomogeneous injections, satisfying a necessary condition for the accurate evaluation of dustiness. Simulations are also performed under the conditions of reduced Extraction-Port flow; results confirm the importance of high Extraction-Port flow rate (standard operation) for uniform distribution of fluid tracers. Simulations are also performed under the conditions of delayed powder injection; results show that a uniform aerosol is still achieved provided 0.5 s elapses between powder injection and sampling. PMID:28638167

  19. Acceptance of multiple injectable vaccines in a single immunization visit in The Gambia pre and post introduction of inactivated polio vaccine.

    PubMed

    Idoko, Olubukola T; Hampton, Lee M; Mboizi, Robert B; Agbla, Schadrac C; Wallace, Aaron S; Harris, Jennifer B; Sowe, Dawda; Ehlman, Daniel C; Kampmann, Beate; Ota, Martin O; Hyde, Terri B

    2016-09-22

    As the World Health Organization (WHO) currently recommends that children be protected against 11 different pathogens, it is becoming increasingly necessary to administer multiple injectable vaccines during a single immunization visit. In this study we assess Gambian healthcare providers' and infant caregivers' attitudes and practices related to the administration of multiple injectable vaccines to a child at a single immunization visit before and after the 2015 introduction of inactivated polio vaccine (IPV). IPV introduction increased the number of injectable vaccines recommended for the 4-month immunization visit from two to three in The Gambia. We conducted a cross-sectional questionnaire-based survey before and after the introduction of IPV at 4months of age in a representative sample of all health facilities providing immunizations in The Gambia. Healthcare providers who administer vaccines at the selected health facilities and caregivers who brought infants for their 4month immunization visit were surveyed. Prior to IPV introduction, 9.9% of healthcare providers and 35.7% of infant caregivers expressed concern about a child receiving more than 2 injections in a single visit. Nevertheless, 98.8% and 90.9% of infants received all required vaccinations for the visit before and after IPV introduction, respectively. The only reason why vaccines were not received was vaccine stock-outs. Infant caregivers generally agreed that vaccinators could be trusted to provide accurate information regarding the number of vaccines that a child needed. Healthcare providers and infant caregivers in this resource limited setting accepted an increase in the number of injectable vaccines administered at a single visit even though some expressed concerns about the increase. Published by Elsevier Ltd.

  20. Effect of a single intra-articular injection of bupivacaine on synovial fluid prostaglandin E2 concentrations in normal canine stifles.

    PubMed

    Giangarra, Jenna E; Barry, Sabrina L; Dahlgren, Linda A; Lanz, Otto I; Benitez, Marian E; Werre, Stephen R

    2018-04-25

    To identify if synovial fluid prostaglandin E 2 increases in response to a single intra-articular dose of bupivacaine in the normal canine stifle. There were no significant differences in synovial fluid prostaglandin E 2 (PGE 2 ) concentrations between treatment groups or over time within bupivacaine or saline groups. Samples requiring ≥ 3 arthrocentesis attempts had significantly higher PGE 2 concentrations compared to samples requiring 1 or 2 attempts. Following correction for number of arthrocentesis attempts, PGE 2 concentrations were significantly higher than baseline at 24 and 48 h in the bupivacaine group; however there were no significant differences between the bupivacaine and saline groups. In normal dogs, a single bupivacaine injection did not cause significant synovial inflammation, as measured by PGE 2 concentrations, compared to saline controls. Future research should minimize aspiration attempts and include evaluation of the synovial response to bupivacaine in clinical cases with joint disease.

  1. Estimation of Glomerular Filtration Rate from Plasma Clearance of 51-Chromium Edetic Acid

    PubMed Central

    Chantler, C.; Barratt, T. M.

    1972-01-01

    The glomerular filtration rate was estimated by a single compartment analysis of the rate of fall of plasma concentration of 51-chromium edetic acid after a single intravenous injection. This slope clearance consistently overestimated the simultaneously determined standard urinary clearance, but could be used to predict the latter with an accuracy of ±9% (95% confidence limits). The coefficient of variation of replicate estimates of the slope clearance in the same individual was 3·9%; thus two estimates of glomerular filtration rate by this technique which differ by 11% have a 95% probability of reflecting a genuine difference. The method requires an intravenous injection and blood samples at 2 and 4 hours; urine samples are not required. It is simple, safe, and precise, and is applicable to children. PMID:4625784

  2. Injection by hydrostatic pressure in conjunction with electrokinetic force on a microfluidic chip.

    PubMed

    Gai, Hongwei; Yu, Linfen; Dai, Zhongpeng; Ma, Yinfa; Lin, Bingcheng

    2004-06-01

    A simple method was developed for injecting a sample on a cross-form microfluidic chip by means of hydrostatic pressure combined with electrokinetic forces. The hydrostatic pressure was generated simply by adjusting the liquid level in different reservoirs without any additional driven equipment such as a pump. Two dispensing strategies using a floating injection and a gated injection, coupled with hydrostatic pressure loading, were tested. The fluorescence observation verified the feasibility of hydrostatic pressure loading in the separation of a mixture of fluorescein sodium salt and fluorescein isothiocyanate. This method was proved to be effective in leading cells to a separation channel for single cell analysis.

  3. Impact of rail pressure and biodiesel fueling on the particulate morphology and soot nanostructures from a common-rail turbocharged direct injection diesel engine

    DOE PAGES

    Ye, Peng; Vander Wal, Randy; Boehman, Andre L.; ...

    2014-12-26

    The effect of rail pressure and biodiesel fueling on the morphology of exhaust particulate agglomerates and the nanostructure of primary particles (soot) was investigated with a common-rail turbocharged direct injection diesel engine. The engine was operated at steady state on a dynamometer running at moderate speed with both low (30%) and medium–high (60%) fixed loads, and exhaust particulate was sampled for analysis. Ultra-low sulfur diesel and its 20% v/v blends with soybean methyl ester biodiesel were used. Fuel injection occurred in a single event around top dead center at three different injection pressures. Exhaust particulate samples were characterized with TEMmore » imaging, scanning mobility particle sizing, thermogravimetric analysis, Raman spectroscopy, and XRD analysis. Particulate morphology and oxidative reactivity were found to vary significantly with rail pressure and with biodiesel blend level. Higher biodiesel content led to increases in the primary particle size and oxidative reactivity but did not affect nanoscale disorder in the as-received samples. For particulates generated with higher injection pressures, the initial oxidative reactivity increased, but there was no detectable correlation with primary particle size or nanoscale disorder.« less

  4. Impact of rail pressure and biodiesel fueling on the particulate morphology and soot nanostructures from a common-rail turbocharged direct injection diesel engine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ye, Peng; Vander Wal, Randy; Boehman, Andre L.

    The effect of rail pressure and biodiesel fueling on the morphology of exhaust particulate agglomerates and the nanostructure of primary particles (soot) was investigated with a common-rail turbocharged direct injection diesel engine. The engine was operated at steady state on a dynamometer running at moderate speed with both low (30%) and medium–high (60%) fixed loads, and exhaust particulate was sampled for analysis. Ultra-low sulfur diesel and its 20% v/v blends with soybean methyl ester biodiesel were used. Fuel injection occurred in a single event around top dead center at three different injection pressures. Exhaust particulate samples were characterized with TEMmore » imaging, scanning mobility particle sizing, thermogravimetric analysis, Raman spectroscopy, and XRD analysis. Particulate morphology and oxidative reactivity were found to vary significantly with rail pressure and with biodiesel blend level. Higher biodiesel content led to increases in the primary particle size and oxidative reactivity but did not affect nanoscale disorder in the as-received samples. For particulates generated with higher injection pressures, the initial oxidative reactivity increased, but there was no detectable correlation with primary particle size or nanoscale disorder.« less

  5. The effect of supportive E. coli mastitis treatment on PMN chemiluminescence and subpopulations of T lymphocytes.

    PubMed

    Markiewicz, H; Krumrych, W; Gehrke, M

    2013-01-01

    The aim of this field study was to assess the impact of a single i.m. injection of lysozyme dimer and flunixin meglumine in combination with intramammary and systemic antibiotic on chemiluminescence of PMN (polymorphonuclear leucocytes) and subpopulations of lymphocyte T in blood of cows with E. coli mastitis. Examinations were performed on 30 dairy cows affected with naturally occurring acute form of E. coli mastitis. Cows were randomly divided into three groups according to the method of treatment. The first group was treated with approved intramammary antibiotic product, the same antibiotic in i.m. injection and one injection of flunixin meglumine on the first day of therapy. Next group was treated with the same antibiotic and additionally one injection of lysozyme dimer on the first day of therapy. The third one was treated only with an antibiotic and served as a control group. Blood samples were taken before treatment and on days 3 and 7. In samples haematology indices were determined, spontaneous and opsonised zymosan stimulated CL and PMA measurements were performed and the subpopulations of T lymphocyte (CD2(+), CD4(+), CD8(+)) were assayed in whole blood. There was no effect of the applied supportive treatment on the value of morphological blood indices. A significant influence of the time of sample collection on the level of CL and dynamics of lymphocytes T subpopulation was demonstrated. A single injection of flunixin meglumine or lysozyme dimer on the day of the beginning of treatment of E. coli mastitis, does not affect the level of neutrophil chemiluminescence and the percentage of T lymphocytes in the blood of mastitic cows in the analysed period of time.

  6. The evaluation of the optimization design and application effect of same-well-injection-production technique’s injection-production circulatory system

    NASA Astrophysics Data System (ADS)

    Guoxing, Zheng; Minghu, Jiang; Hongliang, Gong; Nannan, Zhang; Jianguang, Wei

    2018-02-01

    According to basic principles of combining series of strata and demands of same-well injection-production technique, the optimization designing method of same-well injection-production technique’s injection-production circulatory system is given. Based on oil-water two-phase model with condition of arbitrarily well network, a dynamic forecast method for the application of same-well injection-production reservoir is established with considering the demands and capacity of same-well injection-production technique, sample wells are selected to launch the forecast evaluation and analysis of same-well injection-production reservoir application’s effect. Results show: single-test-well composite water cut decreases by 4.7% and test-well-group composite water cut decreases by 1.56% under the condition of basically invariant ground water injection rate. The method provides theoretical support for the proof of same-well injection-production technique’s reservoir development improving effect and further tests.

  7. Redesigning flow injection after 40 years of development: Flow programming.

    PubMed

    Ruzicka, Jaromir Jarda

    2018-01-01

    Automation of reagent based assays, by means of Flow Injection (FI), is based on sample processing, in which a sample flows continuously towards and through a detector for quantification of the target analyte. The Achilles heel of this methodology, the legacy of Auto Analyzer®, is continuous reagent consumption, and continuous generation of chemical waste. However, flow programming, assisted by recent advances in precise pumping, combined with the lab-on-valve technique, allows the FI manifold to be designed around a single confluence point through which sample and reagents are sequentially directed by means of a series of flow reversals. This approach results in sample/reagent mixing analogous to the traditional FI, reduces sample and reagent consumption, and uses the stop flow technique for enhancement of the yield of chemical reactions. The feasibility of programmable Flow Injection (pFI) is documented by example of commonly used spectrophotometric assays of, phosphate, nitrate, nitrite and glucose. Experimental details and additional information are available in online tutorial http://www.flowinjectiontutorial.com/. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Planar optical waveguide based sandwich assay sensors and processes for the detection of biological targets including protein markers, pathogens and cellular debris

    DOEpatents

    Martinez, Jennifer S [Santa Fe, NM; Swanson, Basil I [Los Alamos, NM; Grace, Karen M [Los Alamos, NM; Grace, Wynne K [Los Alamos, NM; Shreve, Andrew P [Santa Fe, NM

    2009-06-02

    An assay element is described including recognition ligands bound to a film on a single mode planar optical waveguide, the film from the group of a membrane, a polymerized bilayer membrane, and a self-assembled monolayer containing polyethylene glycol or polypropylene glycol groups therein and an assay process for detecting the presence of a biological target is described including injecting a biological target-containing sample into a sensor cell including the assay element, with the recognition ligands adapted for binding to selected biological targets, maintaining the sample within the sensor cell for time sufficient for binding to occur between selected biological targets within the sample and the recognition ligands, injecting a solution including a reporter ligand into the sensor cell; and, interrogating the sample within the sensor cell with excitation light from the waveguide, the excitation light provided by an evanescent field of the single mode penetrating into the biological target-containing sample to a distance of less than about 200 nanometers from the waveguide thereby exciting the fluorescent-label in any bound reporter ligand within a distance of less than about 200 nanometers from the waveguide and resulting in a detectable signal.

  9. Planar optical waveguide based sandwich assay sensors and processes for the detection of biological targets including early detection of cancers

    DOEpatents

    Martinez, Jennifer S [Santa Fe, NM; Swanson, Basil I [Los Alamos, NM; Shively, John E [Arcadia, CA; Li, Lin [Monrovia, CA

    2009-06-02

    An assay element is described including recognition ligands adapted for binding to carcinoembryonic antigen (CEA) bound to a film on a single mode planar optical waveguide, the film from the group of a membrane, a polymerized bilayer membrane, and a self-assembled monolayer containing polyethylene glycol or polypropylene glycol groups therein and an assay process for detecting the presence of CEA is described including injecting a possible CEA-containing sample into a sensor cell including the assay element, maintaining the sample within the sensor cell for time sufficient for binding to occur between CEA present within the sample and the recognition ligands, injecting a solution including a reporter ligand into the sensor cell; and, interrogating the sample within the sensor cell with excitation light from the waveguide, the excitation light provided by an evanescent field of the single mode penetrating into the biological target-containing sample to a distance of less than about 200 nanometers from the waveguide thereby exciting any bound reporter ligand within a distance of less than about 200 nanometers from the waveguide and resulting in a detectable signal.

  10. Ocular biodistribution of bevasiranib following a single intravitreal injection to rabbit eyes

    PubMed Central

    Dejneka, Nadine S.; Wan, Shanhong; Bond, Ottrina S.; Kornbrust, Douglas J.

    2008-01-01

    Purpose The primary objective of these investigations was to determine the ocular biodistribution of bevasiranib, a small interfering RNA (siRNA) targeting vascular endothelial growth factor A (VEGF-A), following a single intravitreal injection to rabbit eyes. Methods A tissue distribution and pharmacokinetic study was conducted with 3H-bevasiranib prepared in balanced-salt solution (BSS). Single doses of either 0.5 mg/eye or 2.0 mg/eye of 3H-bevasiranib were given by intravitreal injection to Dutch-Belted rabbits (both eyes were treated). Subgroups of rabbits were serially-sacrificed at various times up to 7 days following dosing for collection of tissue samples. The right eye of each rabbit was collected whole, and the left eye was dissected to isolate five ocular tissues. All samples were analyzed by liquid scintillation counting to determine the concentrations of bevasiranib equivalents. An ocular disposition study was also performed with non-radiolabeled bevasiranib, which was administered to Dutch-Belted rabbit eyes via intravitreal injection at a dose of 2.0 mg/eye. Twenty-four hours post-dose, the eyes were enucleated and dissected into eight individual ocular structures that were analyzed for intact bevasiranib using a locked nuleic acid (LNA) noncompetitive hybridization-ligation enzyme-linked immunosorbent assay. Results Following intravitreal injection of 0.5 mg or 2.0 mg radiolabeled bevasiranib to Dutch-Belted rabbits, bevasiranib was detected in the vitreous, iris, retina, retinal pigment epithelium (RPE), and sclera (+choroid). As expected, the highest concentrations were found in the vitreous, and vitreous levels steadily decreased over time, while concentrations of radioactivity in the other ocular tissues increased to maximum values between 24 h and 72 h after dosing. Of these tissues, the highest concentration of radioactivity was detected in the retina. The LNA assay further confirmed the presence of intact bevasiranib in these tissues 24 h following intravitreal injection of non-radiolabeled bevasiranib (2 mg/eye). Conclusions These studies demonstrate distribution of bevasiranib throughout the eye following intravitreal injection, including extensive uptake into the retina. PMID:18523657

  11. Contamination of injectable solutions with 2-mercaptobenzothiazole leached from rubber closures.

    PubMed

    Reepmeyer, J C; Juhl, Y H

    1983-11-01

    An impurity, discovered in a sample of digoxin injectable solution commercially packaged in a syringe for single-dose delivery, was found to originate from the rubber closure of the syringe and was identified as 2-mercaptobenzothiazole, a common accelerator for rubber vulcanization. Several similarly packaged injectable solutions of a variety of drugs from various manufacturers were examined and over half contained 2-mercaptobenzothiazole. The compound was identified by UV spectrophotometry (including a pH-dependent shift in its absorbance maximum), by mass spectrometry, and by comparison with standard 2-mercaptobenzothiazole using silica gel and reverse-phase high-performance liquid chromatography (HPLC). The presence of this impurity in injectable solutions may have implications with regard to toxicity and may interfere with the assay of digoxin injectable solution by HPLC.

  12. Analyses of sulfonamide antibiotics by a successive anion- and cation-selective injection coupled to microemulsion electrokinetic chromatography.

    PubMed

    Lin, Yun-Ta; Liu, Yu-Wei; Cheng, Yi-Jie; Huang, Hsi-Ya

    2010-07-01

    In this study, an MEEKC was used to detect and analyze nine sulfonamide antibiotics. Owing to an insufficient sensitivity of on-column UV detection, a field-amplified sample injection, successive anion- and cation-selective injection, was used for the on-line concentration of the nine antibiotics. In the successive anion- and cation-selective injection mode, a leading water plug was introduced prior to anion injection, and then an acidic plug followed by a terminal water plug had to be used before subsequent cation injection. The results indicated some sulfonamides (sulfamonomethoxine, sulfamethazine, sulfamerazine and sulfadiazine) were determined as split signals in pairs, and this was likely due to the use of a longer acid plug (360 s) which caused the sulfonamide anions and cations to be stacked in two distinct zones of the leading water and acid plugs. Meanwhile, all the sulfonamides that were introduced either by anion or cation injection were stacked within the leading water plug when a shorter acid plug (210 s) was used. As a result, the nine sulfonamides were determined as single and symmetrical peaks with low LODs (0.9-4.2 microg/L). Furthermore, the MEEKC method was successfully applied for the detection of trace sulfonamide residues in several food and water samples.

  13. Large-volume injection of sample diluents not miscible with the mobile phase as an alternative approach in sample preparation for bioanalysis: an application for fenspiride bioequivalence.

    PubMed

    Medvedovici, Andrei; Udrescu, Stefan; Albu, Florin; Tache, Florentin; David, Victor

    2011-09-01

    Liquid-liquid extraction of target compounds from biological matrices followed by the injection of a large volume from the organic layer into the chromatographic column operated under reversed-phase (RP) conditions would successfully combine the selectivity and the straightforward character of the procedure in order to enhance sensitivity, compared with the usual approach of involving solvent evaporation and residue re-dissolution. Large-volume injection of samples in diluents that are not miscible with the mobile phase was recently introduced in chromatographic practice. The risk of random errors produced during the manipulation of samples is also substantially reduced. A bioanalytical method designed for the bioequivalence of fenspiride containing pharmaceutical formulations was based on a sample preparation procedure involving extraction of the target analyte and the internal standard (trimetazidine) from alkalinized plasma samples in 1-octanol. A volume of 75 µl from the octanol layer was directly injected on a Zorbax SB C18 Rapid Resolution, 50 mm length × 4.6 mm internal diameter × 1.8 µm particle size column, with the RP separation being carried out under gradient elution conditions. Detection was made through positive ESI and MS/MS. Aspects related to method development and validation are discussed. The bioanalytical method was successfully applied to assess bioequivalence of a modified release pharmaceutical formulation containing 80 mg fenspiride hydrochloride during two different studies carried out as single-dose administration under fasting and fed conditions (four arms), and multiple doses administration, respectively. The quality attributes assigned to the bioanalytical method, as resulting from its application to the bioequivalence studies, are highlighted and fully demonstrate that sample preparation based on large-volume injection of immiscible diluents has an increased potential for application in bioanalysis.

  14. The assesment of effectiveness of plasmonic resonance photothermal therapy in tumor-bearing rats after multiple intravenous administration of gold nanorods

    NASA Astrophysics Data System (ADS)

    Bucharskaya, Alla B.; Maslyakova, Galina N.; Navolokin, Nikita A.; Terentyuk, Georgy S.; Khlebtsov, Boris N.; Khlebtsov, Nikolai G.; Bashkatov, Alexey N.; Genina, Elina A.; Tuchin, V. V.

    2017-03-01

    To assess the effectiveness of plasmonic photothermal therapy (PPT) multiple intravenous strategy of gold nanorods (GNRs) administration was used before laser exposure. The model of alveolar liver cancer PC-1 was used in male outbred albino rats, which were intravenously administrated by single and multiple injections of GNRs and then were treated by PPT. The gold dosage was 400 μg (single injection group), 800 μg (double injection group), 1200 μg (triple injection group), and absorption maximum of gold nanorods suspension was at the wavelength of 808 nm. 24 hours after last injection the tumors were irradiated by the 808-nm diode laser during 15 min at power density 2.3 W/cm2. Temperature control of the tumor heating was provided by IR imager. 24 hours after the PPT the half of animals from each group was withdrawn from the experiments and the sampling tumor tissue for morphological study was performed. In survived animals the growth of tumors was evaluated during 21 days after the PPT. The antitumor effects of PPT after triple intravenous injection were comparable with those obtained at direct intratumoral administration of similar total dose of GNRs. The effectiveness of PPT depended on gold accumulation in tumor, probably, due to sufficient vascularization of tumor tissue.

  15. Analytical Chemistry in Microenvironments: Single Nerve Cells.

    DTIC Science & Technology

    1992-03-16

    length of the capillary (34). Electroosmotic flow offers three key advantages for separation of small biological samples. First, this flow, if not...from microenvironments (ie. single cells). Indeed, volumes as low as 270 femtoliters have been injected using electroosmotic flow (15). Finally... electroosmotic flow provides a flat flow profile, since there is no stationary support between the origin of flow (capillary wall) and the bulk of solution

  16. Updates to Simulation of a Single-Element Lean-Direct Injection Combustor Using a Polyhedral Mesh Derived From Hanging-Node Elements

    NASA Technical Reports Server (NTRS)

    Wey, Changju Thomas; Liu, Nan-Suey

    2014-01-01

    This paper summarizes the procedures of inserting a thin-layer mesh to existing inviscid polyhedral mesh either with or without hanging-node elements as well as presents sample results from its applications to the numerical solution of a single-element LDI combustor using a releasable edition of the National Combustion Code (NCC).

  17. Updates to Simulation of a Single-Element Lean-Direct Injection Combustor Using a Polyhedral Mesh Derived from Hanging-Node Elements

    NASA Technical Reports Server (NTRS)

    Wey, Thomas; Liu, Nan-Suey

    2014-01-01

    This paper summarizes the procedures of inserting a thin-layer mesh to existing inviscid polyhedral mesh either with or without hanging-node elements as well as presents sample results from its applications to the numerical solution of a single-element LDI combustor using a releasable edition of the National Combustion Code (NCC).

  18. Effect of infliximab on renal injury due to methotrexate in rat.

    PubMed

    Kirbas, Aynur; Cure, Medine Cumhur; Kalkan, Yildiray; Cure, Erkan; Tumkaya, Levent; Sahin, Osman Zikrullah; Yuce, Suleyman; Kizilkaya, Bayram; Pergel, Ahmet

    2015-05-01

    Methotrexate, an antagonist of folic acid used in the treatment of many cancers and inflammatory diseases, is associated with side effects that limit its usage. Infliximab has been reported to have a protective effect against nephrotoxicity induced by some drugs and ischemic reperfusion. We aimed to investigate whether infliximab has a protective effect against methotrexate-induced nephrotoxicity. We administered methotrexate at a dose of 20 mg/kg as a single intraperitoneal injection in 10 rats (methotrexate group). Another group of 10 rats received a single dose of infliximab, 7 mg/kg, intraperitoneally (infliximab group). The methotrexate and infliximab group received a similar single injection of infliximab 72 hours prior to methotrexate injection. After 72 hours a single dose of methotrexate, 20 mg/kg, was administered intraperitoneally. Five days after methotrexate injection, blood samples were collected and the kidney tissues were removed for biochemical and histological examination. The methotrexate group had significantly higher tissue levels of tumor necrosis factor-α (P = .008), interleukin-1β (P = .04), nitric oxide (P < .001), and adenosine deaminase (P < .001) than the methotrexate and infliximab group after the 5-day study. The methotrexate group also had significantly higher total histological scores (P < .001) and carbonic anhydrase-II activity (P < .001) when compared to the methotrexate and infliximab group. Infliximab has a strong protective effect against methotrexate-induced nephrotoxicity by suppressing cytokines release. It may decrease methotrexate-induced nephrotoxicity by regulating carbonic anhydrase-II enzyme activities and slowing down purine metabolism.

  19. Updates to Simulation of a Single-Element Lean-Direct Injection Combustor Using Arbitary Polyhedral Meshes

    NASA Technical Reports Server (NTRS)

    Wey, Thomas; Liu, Nan-Suey

    2015-01-01

    This paper summarizes the procedures of (1) generating control volumes anchored at the nodes of a mesh; and (2) generating staggered control volumes via mesh reconstructions, in terms of either mesh realignment or mesh refinement, as well as presents sample results from their applications to the numerical solution of a single-element LDI combustor using a releasable edition of the National Combustion Code (NCC).

  20. In-injection port thermal desorption for explosives trace evidence analysis.

    PubMed

    Sigman, M E; Ma, C Y

    1999-10-01

    A gas chromatographic method utilizing thermal desorption of a dry surface wipe for the analysis of explosives trace chemical evidence has been developed and validated using electron capture and negative ion chemical ionization mass spectrometric detection. Thermal desorption was performed within a split/splitless injection port with minimal instrument modification. Surface-abraded Teflon tubing provided the solid support for sample collection and desorption. Performance was characterized by desorption efficiency, reproducibility, linearity of the calibration, and method detection and quantitation limits. Method validation was performed with a series of dinitrotoluenes, trinitrotoluene, two nitroester explosives, and one nitramine explosive. The method was applied to the sampling of a single piece of debris from an explosion containing trinitrotoluene.

  1. Inference and analysis of xenon outflow curves under multi-pulse injection in two-dimensional chromatography.

    PubMed

    Shu-Jiang, Liu; Zhan-Ying, Chen; Yin-Zhong, Chang; Shi-Lian, Wang; Qi, Li; Yuan-Qing, Fan

    2013-10-11

    Multidimensional gas chromatography is widely applied to atmospheric xenon monitoring for the Comprehensive Nuclear-Test-Ban Treaty (CTBT). To improve the capability for xenon sampling from the atmosphere, sampling techniques have been investigated in detail. The sampling techniques are designed by xenon outflow curves which are influenced by many factors, and the injecting condition is one of the key factors that could influence the xenon outflow curves. In this paper, the xenon outflow curves of single-pulse injection in two-dimensional gas chromatography has been tested and fitted as a function of exponential modified Gaussian distribution. An inference formula of the xenon outflow curve for six-pulse injection is derived, and the inference formula is also tested to compare with its fitting formula of the xenon outflow curve. As a result, the curves of both the one-pulse and six-pulse injections obey the exponential modified Gaussian distribution when the temperature of the activated carbon column's temperature is 26°C and the flow rate of the carrier gas is 35.6mLmin(-1). The retention time of the xenon peak for one-pulse injection is 215min, and the peak width is 138min. For the six-pulse injection, however, the retention time is delayed to 255min, and the peak width broadens to 222min. According to the inferred formula of the xenon outflow curve for the six-pulse injection, the inferred retention time is 243min, the relative deviation of the retention time is 4.7%, and the inferred peak width is 225min, with a relative deviation of 1.3%. Copyright © 2013 Elsevier B.V. All rights reserved.

  2. Solid-state carrier-envelope phase stabilization via quantum interference control of injected photocurrents.

    PubMed

    Roos, P A; Li, Xiaoqin; Smith, R P; Pipis, Jessica A; Fortier, T M; Cundiff, S T

    2005-04-01

    We demonstrate carrier-envelope phase stabilization of a mode-locked Ti:sapphire laser by use of quantum interference control of injected photocurrents in a semiconductor. No harmonic generation is required for this stabilization technique. Instead, interference between coexisting single- and two-photon absorption pathways in the semiconductor provides a phase comparison between different spectral components. The phase comparison, and the detection of the photocurrent that it produces, both occur within a single low-temperature-grown gallium arsenide sample. The carrier-envelope offset beat note fidelity is 30 dB in a 10-kHz resolution bandwidth. The out-of-loop phase-noise level is essentially identical to the best previous measurements with the standard self-referencing technique.

  3. AUTOMATED ANALYSIS OF AQUEOUS SAMPLES CONTAINING PESTICIDES, ACIDIC/BASIC/NEUTRAL SEMIVOLATILES AND VOLATILE ORGANIC COMPOUNDS BY SOLID PHASE EXTRACTION COUPLED IN-LINE TO LARGE VOLUME INJECTION GC/MS

    EPA Science Inventory

    Data is presented on the development of a new automated system combining solid phase extraction (SPE) with GC/MS spectrometry for the single-run analysis of water samples containing a broad range of organic compounds. The system uses commercially available automated in-line 10-m...

  4. Dramatic changes in muscle contractile and structural properties after 2 botulinum toxin injections.

    PubMed

    Minamoto, Viviane B; Suzuki, Kentaro P; Bremner, Shannon N; Lieber, Richard L; Ward, Samuel R

    2015-10-01

    Botulinum toxin is frequently administered serially to maintain therapeutic muscle paralysis, but the effect of repeated doses on muscle function are largely unknown. This study characterized the muscle response to 2 onabotulinum toxin (BoNT) injections separated by 3 months. Animal subjects received a single toxin injection (n = 8), 2 BoNT injections separated by 3 months (n = 14), or 1 BoNT and 1 saline injection separated by 3 months (n = 8). The functional effect of 2 serial injections was exponentially greater than the effect of a single injection. While both groups treated with a single BoNT injection had decreased torque in the injected leg by approximately 50% relative to contralateral legs, the double BoNT injected group had decreased torque by over 95% relative to the preinjection level. Both single and double BoNT injections produced clear signs of fiber-type grouping. These experiments demonstrate a disproportionately greater effect of repeated BoNT injections. © 2015 Wiley Periodicals, Inc.

  5. 21 CFR 522.460 - Cloprostenol sodium.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... which cycling cows or heifers can be bred. (1) Single cloprostenol injection. Treat only animals with a... about 72 hours post injection or twice at 72 and 96 hours following the second injection. (b) Single... cysts. (c) Single cloprostenol injection for the treatment of pyometra. (iii) Do not administer to...

  6. [Pro re nata anti-VEGF treatment results for neovascular age-related macular degeneration in routine clinical treatment: comparison of single with triple injections].

    PubMed

    Wintergerst, M W M; Larsen, P P; Heimes, B; Pauleikhoff, D; Holz, F G; Finger, R P

    2018-06-19

    Different injection regimens from continuous to pro re nata (PRN) have been proposed for treatment of neovascular age-related macular degeneration (nAMD). So far the PRN single injection on reactivation regimen has not been compared to the PRN triple injection on reactivation regimen (IVAN scheme). Comparison of the two nAMD PRN injection regimens with single and triple injections on reactivation in a real-world setting in a retrospective case series in two German treatment centers. Naïve nAMD patients, who started treatment according to either the single or triple injection regimen were included. Endpoints were best corrected visual acuity (LogMAR), central retinal thickness on optical coherence tomography (μm) and number of injections, all at 3, 6, 12, 18 and 24 months after treatment initiation. A total of 146 patients with single injection and 148 patients with triple injection regimens were included. There were no significant differences between the two treatment regimens in best corrected visual acuity (single vs. triple injection scheme: 0.50 ± 0.42 vs. 0.56 ± 0.42, p = 0.14), central retinal thickness (303 ± 76.2 vs. 306 ± 110, p = 0.79) and number of injections (13 ± 4.4 vs. 12 ± 5.4, p = 0.31). This was the case for all analyzed time points. There were no significant functional or morphological differences between the two PRN injection regimens with single and triple injections on reactivation after 24 months. For evaluation of long-term therapy results further studies are warranted.

  7. Rapid and efficient detection of single chromophore molecules in aqueous solution

    NASA Astrophysics Data System (ADS)

    Li, Li-Qiang; Davis, Lloyd M.

    1995-06-01

    The first experiments on the detection of single fluorescent molecules in a flowing stream of an aqueous solution with high total efficiency are reported. A capillary injection system for sample delivery causes all the dye molecules to pass in a diffusion-broadened stream within a fast-moving sheath flow, through the center of the tightly focused laser excitation beam. Single-molecule detection with a transit time of approximately 1 ms is accomplished with a high-quantum-efficiency single-photon avalanche diode and a low dead-time time-gating circuit for discrimination of Raman-scattered light from the solvent.

  8. Sample flow switching techniques on microfluidic chips.

    PubMed

    Pan, Yu-Jen; Lin, Jin-Jie; Luo, Win-Jet; Yang, Ruey-Jen

    2006-02-15

    This paper presents an experimental investigation into electrokinetically focused flow injection for bio-analytical applications. A novel microfluidic device for microfluidic sample handling is presented. The microfluidic chip is fabricated on glass substrates using conventional photolithographic and chemical etching processes and is bonded using a high-temperature fusion method. The proposed valve-less device is capable not only of directing a single sample flow to a specified output port, but also of driving multiple samples to separate outlet channels or even to a single outlet to facilitate sample mixing. The experimental results confirm that the sample flow can be electrokinetically pre-focused into a narrow stream and guided to the desired outlet port by means of a simple control voltage model. The microchip presented within this paper has considerable potential for use in a variety of applications, including high-throughput chemical analysis, cell fusion, fraction collection, sample mixing, and many other applications within the micro-total-analysis systems field.

  9. An experimental study of fuel injection strategies in CAI gasoline engine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hunicz, J.; Kordos, P.

    2011-01-15

    Combustion of gasoline in a direct injection controlled auto-ignition (CAI) single-cylinder research engine was studied. CAI operation was achieved with the use of the negative valve overlap (NVO) technique and internal exhaust gas re-circulation (EGR). Experiments were performed at single injection and split injection, where some amount of fuel was injected close to top dead centre (TDC) during NVO interval, and the second injection was applied with variable timing. Additionally, combustion at variable fuel-rail pressure was examined. Investigation showed that at fuel injection into recompressed exhaust fuel reforming took place. This process was identified via an analysis of the exhaust-fuelmore » mixture composition after NVO interval. It was found that at single fuel injection in NVO phase, its advance determined the heat release rate and auto-ignition timing, and had a strong influence on NO{sub X} emission. However, a delay of single injection to intake stroke resulted in deterioration of cycle-to-cycle variability. Application of split injection showed benefits of this strategy versus single injection. Examinations of different fuel mass split ratios and variable second injection timing resulted in further optimisation of mixture formation. At equal share of the fuel mass injected in the first injection during NVO and in the second injection at the beginning of compression, the lowest emission level and cyclic variability improvement were observed. (author)« less

  10. Terahertz injection lasers based on PbSnSe alloy with an emission wavelength up to 46.5 μm

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maremyanin, K. V., E-mail: kirillm@ipmras.ru; Rumyantsev, V. V.; Ikonnikov, A. V.

    2016-12-15

    Diffusion injection lasers based on Pb{sub 1} {sub –} {sub x}Sn{sub x}Se alloy, emitting in a wide spectral range of 10–46.5 μm depending on the composition and temperatures are fabricated. A technology for growing high-quality single crystals from the vapor phase under conditions of free growth is developed. The dependences of the total emission intensity on the pump current and the emission spectra of injection lasers based on Pb{sub 1–x}Sn{sub x}Se are studied. In these samples, lasing of long-wavelength radiation to a record wavelength of 46.5 μm is achieved.

  11. Kinetic modeling of PET-FDG in the brain without blood sampling.

    PubMed

    Bentourkia, M'hamed

    2006-12-01

    The aim in this work is to report a new method to calculate parametric images from a single scan acquisition with positron emission tomography (PET) and fluorodeoxyglucose (FDG) in the human brain without blood sampling. It is usually practical for research or clinical purposes to inject the patient in an isolated room and to start the PET acquisition only for some 10-20 min, about 30 min after FDG injection. In order to calculate the cerebral metabolic rates for glucose (CMRG), usually several blood samples are required. The proposed method considers the relation between the uptake of the tracer in the cerebellum as a reference tissue and the population based input curve. Similar results were obtained for CMRG values with the present method in comparison to the usual autoradiographic and the non-linear least squares fitting of regions of interest.

  12. Efficient coupling of starlight into single mode photonics using Adaptive Injection (AI)

    NASA Astrophysics Data System (ADS)

    Norris, Barnaby; Cvetojevic, Nick; Gross, Simon; Arriola, Alexander; Tuthill, Peter; Lawrence, Jon; Richards, Samuel; Goodwin, Michael; Zheng, Jessica

    2016-08-01

    Using single-mode fibres in astronomy enables revolutionary techniques including single-mode interferometry and spectroscopy. However, injection of seeing-limited starlight into single mode photonics is extremely difficult. One solution is Adaptive Injection (AI). The telescope pupil is segmented into a number of smaller subapertures each with size r0, such that seeing can be approximated as a single tip / tilt / piston term for each subaperture, and then injected into a separate fibre via a facet of a segmented MEMS deformable mirror. The injection problem is then reduced to a set of individual tip tilt loops, resulting in high overall coupling efficiency.

  13. Field demonstration of CO2 leakage detection and potential impacts on groundwater quality at Brackenridge Field Laboratory

    NASA Astrophysics Data System (ADS)

    Zou, Y.; Yang, C.; Guzman, N.; Delgado, J.; Mickler, P. J.; Horvoka, S.; Trevino, R.

    2015-12-01

    One concern related to GCS is possible risk of unintended CO2 leakage from the storage formations into overlying potable aquifers on underground sources of drinking water (USDW). Here we present a series of field tests conducted in an alluvial aquifer which is on a river terrace at The University of Texas Brackenridge Field Laboratory. Several shallow groundwater wells were completed to the limestone bedrock at a depth of 6 m and screened in the lower 3 m. Core sediments recovered from the shallow aquifer show that the sediments vary in grain size from clay-rich layers to coarse sandy gravels. Two main types of field tests were conducted at the BFL: single- (or double-) well push-pull test and pulse-like CO2 release test. A single- (or double-) well push-pull test includes three phases: the injection phase, the resting phase and pulling phase. During the injection phase, groundwater pumped from the shallow aquifer was stored in a tank, equilibrated with CO2 gasand then injected into the shallow aquifer to mimic CO2 leakage. During the resting phase, the groundwater charged with CO2 reacted with minerals in the aquifer sediments. During the pulling phase, groundwater was pumped from the injection well and groundwater samples were collected continuously for groundwater chemistry analysis. In such tests, large volume of groundwater which was charged with CO2 can be injected into the shallow aquifer and thus maximize contact of groundwater charged with CO2. Different than a single- (or double-) well push-pull test, a pulse-like CO2 release test for validating chemical sensors for CO2 leakage detection involves a CO2 release phase that CO2 gas was directly bubbled into the testing well and a post monitoring phase that groundwater chemistry was continuously monitored through sensors and/or grounder sampling. Results of the single- (or double-) well push-pull tests conducted in the shallow aquifer shows that the unintended CO2 leakage could lead to dissolution of carbonates and some silicates and mobilization of heavy metals from the aquifer sediments to groundwater, however, such mobilization posed no risks on groundwater quality at this site. The pulse-like tests have demonstrated it is plausible to use chemical sensors for CO2 leakage detection in groundwater.

  14. Repeated onabotulinumtoxin-a injections provide better results than single injection in treatment of painful bladder syndrome.

    PubMed

    Kuo, Hann-Chorng

    2013-01-01

    Onabotulinumtoxin-A (BoNT-A) is effective for the treatment of interstitial cystitis/painful bladder syndrome (IC/PBS). However, long-term follow-up does not show successful outcome after a single injection. To evaluate the efficacy and safety of repeated intravesical BoNT-A injections for treatment of IC/PBS and compare the success rates among patient groups receiving different injection numbers. Prospective interventional study. Tertiary medical center. Intravesical injection of 100 U of BoNT-A was performed in 81 patients every 6 months for up to 4 times or until patients' symptoms significantly improved. Patients who received a single injection served as active controls. Measured parameters included O'Leary-Sant symptom indexes (ICSI) and problem indexes (ICPI), visual analogue score (VAS) for pain, voiding diary variables, urodynamic parameters, maximal bladder capacity under anesthesia, glomerulation grade, and global response assessment. Multiple measurements and Kaplan-Meier analysis were used for comparison of consecutive data and success rates among groups. Among 81 patients, 20 received single injections, 19 received 2 injections, 12 received 3 injections, and 30 received 4 injections. The mean (± standard deviation) of ICSI, ICPI, total scores, VAS, functional bladder capacity, and daytime frequency all showed significant improvement after repeated BoNT-A treatment with different injections. Significantly better success rates were noted in patients who received 4 repeated injections (P = 0.0242) and 3 injections (P = 0.050), compared to those who received a single injection. However, there was no significant difference of long-term success rates among patients who received 2, 3, and 4 injections. Lack of placebo control group is the main limitation. Repeated intravesical BoNT-A injections were safe and effective for pain relief and they increased bladder capacity and provided a better long-term success rate than a single injection did for treatment of IC/PBS.

  15. Assessment of nitrification potential in ground water using short term, single-well injection experiments

    USGS Publications Warehouse

    Smith, R.L.; Baumgartner, L.K.; Miller, D.N.; Repert, D.A.; Böhlke, J.K.

    2006-01-01

    Nitrification was measured within a sand and gravel aquifer on Cape Cod, MA, using a series of single-well injection tests. The aquifer contained a wastewater-derived contaminant plume, the core of which was anoxic and contained ammonium. The study was conducted near the downgradient end of the ammonium zone, which was characterized by inversely trending vertical gradients of oxygen (270 to 0 μM) and ammonium (19 to 625 μM) and appeared to be a potentially active zone for nitrification. The tests were conducted by injecting a tracer solution (ambient ground water + added constituents) into selected locations within the gradients using multilevel samplers. After injection, the tracers moved by natural ground water flow and were sampled with time from the injection port. Rates of nitrification were determined from changes in nitrate and nitrite concentration relative to bromide. Initial tests were conducted with 15N-enriched ammonium; subsequent tests examined the effect of adding ammonium, nitrite, or oxygen above background concentrations and of adding difluoromethane, a nitrification inhibitor. In situ net nitrate production exceeded net nitrite production by 3- to 6- fold and production rates of both decreased in the presence of difluoromethane. Nitrification rates were 0.02–0.28 μmol (L aquifer)−1 h−1 with in situ oxygen concentrations and up to 0.81 μmol (L aquifer)−1 h−1 with non-limiting substrate concentrations. Geochemical considerations indicate that the rates derived from single-well injection tests yielded overestimates of in situ rates, possibly because the injections promoted small-scale mixing within a transport-limited reaction zone. Nonetheless, these tests were useful for characterizing ground water nitrification in situ and for comparing potential rates of activity when the tracer cloud included non-limiting ammonium and oxygen concentrations.

  16. Single hole multi-parameter downhole monitoring of shallow CO2 injection at Maguelone experimental site (Languedoc, France)

    NASA Astrophysics Data System (ADS)

    Denchik, N.; Pezard, P. A.; Abdoulghafour, H.; Lofi, J.; Neyens, D.; Perroud, H.; Henry, G.; Rolland, B.

    2015-12-01

    The Maguelone experimental site for shallow subsurface hydrogeophysical monitoring, located along the Mediterranean Lido near Montpellier (Languedoc, France) has proven over the years to provide a unique setup to test gas storage monitoring methods at shallow depth. The presence of two small reservoirs (R1: 13-16 m and R2: 8-9 m) with impermeable boundaries provides an opportunity to study a saline formation for geological storage both in the field and in a laboratory context. This integrated monitoring concept was first applied at Maguelone for characterization of the reservoir state before and during N2 and CO2 injections as part of the MUSTANG FP7 project. Multimethod monitoring was shown to be sensitive to gas storage within a saline reservoir with clear data changes immediately after the beginning of injection. Pressure remains the first indicator of gas storage at ~8-9 m depth in a small permeable unit (gravels/shells) under the Holocene lagoonal sediments. A good correlation is also obtained between the resistivity response and geochemical parameters from pore fluid sampling (pH, minor and major cation concentrations) at this depth. On the basis of previous gas injection experiments, new holes were drilled as part of PANACEA (EC project) in 2014, including an injection hole targeted for injection at 8-9 m depth in the R2 reservoir in order to have gas injection and gas storage at the same depth, a single hole multi-parameter observatory, and a seismic source hole. A total volume of ~48 m3 of CO2 was injected over ~2 hours on December 4, 2014. The injection rate varied from 24 to 30 m3/h, with a well head pressure of 1.8 bars. All downhole monitoring technologies (resistivity, temperature, pressure, SP and seismic measurements) were combined in the single hole observatory. Such device allows monitoring the downhole system before and after injection and the gas migration from the injection hole, helping to characterize the transport mechanism. Decreasing the number of monitoring-measurements and verification (MMV) holes enables a significant decrease of gas leakage risk. This specific monitoring approach is expected to give information about the safety and reliability of CO2 storage operation that guarantees public acceptance.

  17. A METHOD FOR AUTOMATED ANALYSIS OF 10 ML WATER SAMPLES CONTAINING ACIDIC, BASIC, AND NEUTRAL SEMIVOLATILE COMPOUNDS LISTED IN USEPA METHOD 8270 BY SOLID PHASE EXTRACTION COUPLED IN-LINE TO LARGE VOLUME INJECTION GAS CHROMATOGRAPHY/MASS SPECTROMETRY

    EPA Science Inventory

    Data is presented showing the progress made towards the development of a new automated system combining solid phase extraction (SPE) with gas chromatography/mass spectrometry for the single run analysis of water samples containing a broad range of acid, base and neutral compounds...

  18. Optimization of mass spectrometric parameters improve the identification performance of capillary zone electrophoresis for single-shot bottom-up proteomics analysis.

    PubMed

    Zhang, Zhenbin; Dovichi, Norman J

    2018-02-25

    The effects of MS1 injection time, MS2 injection time, dynamic exclusion time, intensity threshold, and isolation width were investigated on the numbers of peptide and protein identifications for single-shot bottom-up proteomics analysis using CZE-MS/MS analysis of a Xenopus laevis tryptic digest. An electrokinetically pumped nanospray interface was used to couple a linear-polyacrylamide coated capillary to a Q Exactive HF mass spectrometer. A sensitive method that used a 1.4 Th isolation width, 60,000 MS2 resolution, 110 ms MS2 injection time, and a top 7 fragmentation produced the largest number of identifications when the CZE loading amount was less than 100 ng. A programmable autogain control method (pAGC) that used a 1.4 Th isolation width, 15,000 MS2 resolution, 110 ms MS2 injection time, and top 10 fragmentation produced the largest number of identifications for CZE loading amounts greater than 100 ng; 7218 unique peptides and 1653 protein groups were identified from 200 ng by using the pAGC method. The effect of mass spectrometer conditions on the performance of UPLC-MS/MS was also investigated. A fast method that used a 1.4 Th isolation width, 30,000 MS2 resolution, 45 ms MS2 injection time, and top 12 fragmentation produced the largest number of identifications for 200 ng UPLC loading amount (6025 unique peptides and 1501 protein groups). This is the first report where the identification number for CZE surpasses that of the UPLC at the 200 ng loading level. However, more peptides (11476) and protein groups (2378) were identified by using UPLC-MS/MS when the sample loading amount was increased to 2 μg with the fast method. To exploit the fast scan speed of the Q-Exactive HF mass spectrometer, higher sample loading amounts are required for single-shot bottom-up proteomics analysis using CZE-MS/MS. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Safe and Effective Use of the Once Weekly Dulaglutide Single-Dose Pen in Injection-Naïve Patients With Type 2 Diabetes.

    PubMed

    Matfin, Glenn; Van Brunt, Kate; Zimmermann, Alan G; Threlkeld, Rebecca; Ignaut, Debra A

    2015-04-21

    This 4-week, phase 3b, multicenter, open-label, single-arm, outpatient study demonstrated the safe and effective use of the dulaglutide single-dose pen containing 0.5 mL of placebo for subcutaneous injection in injection-naïve adult patients with type 2 diabetes (T2D), with A1C ≤ 8.5% (69 mmol/mol), BMI ≥ 23 kg/m2 and ≤ 45 kg/m(2). Patients completed a modified self-injecting subscale of the Diabetes Fear of Injecting and Self-Testing Questionnaire (mD-FISQ) and were trained to self-inject with the single-dose pen. Patients completed the initial self-injection at the site, injected at home for 2 subsequent weeks, and returned to the site for the final injection. The initial and final self-injections were evaluated for success; the final (initial) self-injection success rate was the primary (secondary) outcome measure, and the primary (secondary) objective was to demonstrate this success rate as being significantly greater than 80%. Patients recorded their level of pain after each injection. After the final injection, patients completed the mD-FISQ and the Medication Delivery Device Assessment Battery (MDDAB) to assess their perceptions of the single-dose pen, including ease of use and experience with the device. Among 211 patients (mean age: 61 years), the primary objective was met, with a final injection success rate of 99.1% (95% CI: 96.6% to 99.7%). Among 214 patients, the initial injection success rate was 97.2% (95% CI: 94.0% to 98.7%), meeting the key secondary objective. Overall, most patients (>96%) found the device easy to use, were satisfied with the device, and would be willing to continue to use the single-dose pen after the study. There was a significant reduction (P < .001) from baseline to study end in patients' fear of self-injecting, as measured by the mD-FISQ. The dulaglutide single-dose pen was found to be a safe and effective device for use by patients with T2D who were injection-naïve. A positive injection experience is an important factor for patients and providers when initiating injectable therapy. © 2015 Diabetes Technology Society.

  20. Safe and Effective Use of the Once Weekly Dulaglutide Single-Dose Pen in Injection-Naïve Patients With Type 2 Diabetes

    PubMed Central

    Matfin, Glenn; Van Brunt, Kate; Zimmermann, Alan G.; Threlkeld, Rebecca; Ignaut, Debra A.

    2015-01-01

    Background: This 4-week, phase 3b, multicenter, open-label, single-arm, outpatient study demonstrated the safe and effective use of the dulaglutide single-dose pen containing 0.5 mL of placebo for subcutaneous injection in injection-naïve adult patients with type 2 diabetes (T2D), with A1C ≤ 8.5% (69 mmol/mol), BMI ≥ 23 kg/m2 and ≤ 45 kg/m2. Method: Patients completed a modified self-injecting subscale of the Diabetes Fear of Injecting and Self-Testing Questionnaire (mD-FISQ) and were trained to self-inject with the single-dose pen. Patients completed the initial self-injection at the site, injected at home for 2 subsequent weeks, and returned to the site for the final injection. The initial and final self-injections were evaluated for success; the final (initial) self-injection success rate was the primary (secondary) outcome measure, and the primary (secondary) objective was to demonstrate this success rate as being significantly greater than 80%. Patients recorded their level of pain after each injection. After the final injection, patients completed the mD-FISQ and the Medication Delivery Device Assessment Battery (MDDAB) to assess their perceptions of the single-dose pen, including ease of use and experience with the device. Results: Among 211 patients (mean age: 61 years), the primary objective was met, with a final injection success rate of 99.1% (95% CI: 96.6% to 99.7%). Among 214 patients, the initial injection success rate was 97.2% (95% CI: 94.0% to 98.7%), meeting the key secondary objective. Overall, most patients (>96%) found the device easy to use, were satisfied with the device, and would be willing to continue to use the single-dose pen after the study. There was a significant reduction (P < .001) from baseline to study end in patients’ fear of self-injecting, as measured by the mD-FISQ. Conclusions: The dulaglutide single-dose pen was found to be a safe and effective device for use by patients with T2D who were injection-naïve. A positive injection experience is an important factor for patients and providers when initiating injectable therapy. PMID:25901022

  1. Development of simplified external control techniques for broad area semiconductor lasers

    NASA Technical Reports Server (NTRS)

    Davis, Christopher C.

    1993-01-01

    The goal of this project was to injection lock a 500 mW broad area laser diode (BAL) with a single mode low power laser diode with injection beam delivery through a single mode optical fiber (SMF). This task was completed successfully with the following significant accomplishments: (1) injection locking of a BAL through a single-mode fiber using a master oscillator and integrated miniature optics; (2) generation of a single-lobed, high-power far-field pattern from the injection-locked BAL that steers with drive current; and (3) a comprehensive theoretical analysis of a model that describes the observed behavior of the injection locked oscillator.

  2. Electrokinetic injection techniques in microfluidic chips.

    PubMed

    Fu, L M; Yang, R J; Lee, G B; Liu, H H

    2002-10-01

    The separation efficiency of a microfluidic chip is influenced to a significant degree by the flow field conditions within the injection microchannel. Therefore, an understanding of the physics of the flow within this channel is beneficial in the design and operation of such a system. The configuration of an injection system is determined by the volume of the sample plug that is to be delivered to the separation process. Accordingly, this paper addresses the design and testing of injection systems with a variety of configurations, including a simple cross, a double-T, and a triple-T configuration. This paper also presents the design of a unique multi-T injection configuration. Each injection system cycles through a predetermined series of steps, in which the electric field magnitude and distribution within the various channels is strictly manipulated, to effectuate a virtual valve. The uniquemulti-T configuration injection system presented within this paper has the ability to simulate the functions of the cross, double-T, and triple-T systems through appropriate manipulations of the electric field within its various channels. In other words, the proposed design successfully combines several conventional injection systems within a single microfluidic chip.

  3. Rapid colorimetric assay for gentamicin injection.

    PubMed

    Tarbutton, P

    1987-01-01

    A rapid colorimetric method for determining gentamicin concentration in commercial preparations of gentamicin sulfate injection was developed. Methods currently available for measuring gentamicin concentration via its colored complex with cupric ions in alkaline solution were modified to reduce the time required for a single analysis. The alkaline copper tartrate (ACT) reagent solution was prepared such that each milliliter contained 100 mumol cupric sulfate, 210 mumol potassium sodium tartrate, and 1.25 mmol sodium hydroxide. The assay involves mixing 0.3 mL gentamicin sulfate injection 40 mg/mL (of gentamicin), 1.0 mL ACT reagent, and 0.7 mL water; the absorbance of the resulting solution at 560 nm was used to calculate the gentamicin concentration in the sample. For injections containing 10 mg/mL of gentamicin, the amount of the injection was increased to 0.5 mL and water decreased to 0.5 mL. The concentration of gentamicin in samples representing 11 lots of gentamicin sulfate injection 40 mg/mL and 8 lots of gentamicin sulfate injection 10 mg/mL was determined. The specificity, reproducibility, and accuracy of the assay were assessed. The colored complex was stable for at least two hours. Gentamicin concentration ranged from 93.7 to 108% and from 95 to 109% of the stated label value of the 40 mg/mL and the 10 mg/mL injections, respectively. No components of the preservative system present in the injections interfered with the assay. Since other aminoglycosides produced a colored complex, the assay is not specific for gentamicin. The assay was accurate and reproducible over the range of 4-20 mg of gentamicin. This rapid and accurate assay can be easily applied in the hospital pharmacy setting.

  4. Injector-concentrator electrodes for microchannel electrophoresis

    DOEpatents

    Swierkowski, Stefan P.

    2003-05-06

    An input port geometry, with injector-concentrator electrodes, for planar microchannel array for electrophoresis. This input port geometry enables efficient extraction and injection of the DNA sample from a single input port. The geometry, which utilizes injector-concentrator electrodes, allows simultaneous concentration, in different channels, of the sample into a longitudinally narrow strip just before releasing it for a run with enhanced injection spatial resolution, and time resolution. Optional multiple electrodes, at a different bias than the concentrator electrodes, may be used to discriminate against sample impurity ions. Electrode passivation can be utilized to prevent electrolysis. An additional electrode in or on the input hole can better define the initial loading. The injector-concentrator electrodes are positioned so that they cross the drift channel in a narrow strip at the bond plane between the top and bottom plates of the instrument and are located close to the inlet hole. The optional sample purification electrodes are located at a greater distance from the input hole than the injector-concentrate electrodes.

  5. A novel approach for determination of free fatty acids in vegetable oils by a flow injection system with manual injection.

    PubMed

    Ayyildiz, H Filiz; Kara, Huseyin; Sherazi, S T H

    2011-12-01

    A non-aqueous flow injection method for determining free fatty acid (FFA) content in corn and sunflower oil samples was developed. A single-line manifold system was built by modification of an HPLC for flow injection analysis (FIA). Without pre-treatment, oil samples were injected into a n-propanol solution containing KOH and phenolphthalein (PHP). The main parameters, such as flow rate of carrier phase, length, geometry, inner diameters of the coils and reagent concentration were all optimized. The proposed FIA method was validated for precision, accuracy, linear region, limit of detection (LOD) and limit of quantification (LOQ). The intra- and inter-day measurements of the precision of the method were found to be within the limits of acceptance criteria (RSD < 1%), and were rugged when the method was performed by a different analyst. The linear concentration range was calculated as 0.09-1.50 and 0.07-1.40 FFA% for corn and sunflower oils, correspondingly. The LOD and LOQ were found to be 7.53 × 10(-4)-2.28 × 10(-3) oleic acid % and 7.11 × 10(-4)-2.23 × 10(-3) oleic acid % for corn and sunflower oils, respectively. The results were compared with those obtained by the AOCS (Ca-5a-40) method using statistical t and F tests, and a significant difference was not observed between the methods at a 95% confidence level. The proposed method is suitable for quality control of routine applications due to its simplicity, high sample throughput, and economy of solvents and sample, offering considerable promise as a low cost analytical system that needs minimum human intervention over long periods of time.

  6. Flexible nano- and microliter injections on a single liquid chromatography-mass spectrometry system: Minimizing sample preparation and maximizing linear dynamic range.

    PubMed

    Lubin, Arnaud; Sheng, Sheng; Cabooter, Deirdre; Augustijns, Patrick; Cuyckens, Filip

    2017-11-17

    Lack of knowledge on the expected concentration range or insufficient linear dynamic range of the analytical method applied are common challenges for the analytical scientist. Samples that are above the upper limit of quantification are typically diluted and reanalyzed. The analysis of undiluted highly concentrated samples can cause contamination of the system, while the dilution step is time consuming and as the case for any sample preparation step, also potentially leads to precipitation, adsorption or degradation of the analytes. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. [Pharmacokinetics study of amoxicillin sodium clavulanate potassium (10:1) injection in healthy volunteers].

    PubMed

    Miao, Jia; Nan, Feng; Shen, Qi; Qin, Yong-Ping; Wang, Ying; Yu, Qin; Zheng, Li; Liang, Mao-Zhi

    2013-03-01

    To study the pharmacokinetics of amoxicillin sodium clavulanate potassium (10:1) injection with different single doses intravenous infusion and one dose repeated intravenous injection in healthy volunteers for guiding the rational clinical regimen. Using infusion pump constantly intravenous dripping in 30 min, 4 mL blood samples were collected before and after the administration at 10 min, 20 min, 30 min, 45 min, and 1, 1.25, 1.5, 2, 2.5, 3, 4, 6, 8, 10 h. The plasma concentrations of amoxicillin and clavulanate were detected by high performance liquid chromatography- mass spectrometry/mass spectrometry method. The pharmacokinetic parameters were calculated by DAS2.0.1 software. The dispositions of amoxicillin and clavulanate matched three or two compartment model with the weight coefficient 1/cc. To avoid the biases caused by compartment model fitting, the pharmacokinetic parameters were statistical moment parameters of non-compartment model. The peak concentrations, the areas under curve, the half-lifes and the clearances after single injections of 0. 55 g, 1.1 g and 2.2 g indicated that both amoxillin and clavulanate had linear dynamics characteristics. After 1.1 g single dose and multiple doses infusion, the pharmacokinetic parameters of amoxicillin and clavulanate were close respectively, and the trough concentrations before the 7th to 13th administration were lower than the detection limitation, which implied that the previous administration had cleared out before the next administration, and no accumulation happened after multiple doses. The amoxicillin sodium clavulanate potassium (10:1) injection possesses the linear kinetics. The dosage regimen of 1.1 g Q8h intravenous infusion could meet the needs of clinical therapy.

  8. Impact of Azimuthally Controlled Fluidic Chevrons on Jet Noise

    NASA Technical Reports Server (NTRS)

    Henderson, Brenda S.; Norum, Thomas D.

    2008-01-01

    The impact of azimuthally controlled air injection on broadband shock noise and mixing noise for single and dual stream jets was investigated. The single stream experiments focused on noise reduction for low supersonic jet exhausts. Dual stream experiments included high subsonic core and fan conditions and supersonic fan conditions with transonic core conditions. For the dual stream experiments, air was injected into the core stream. Significant reductions in broadband shock noise were achieved in a single jet with an injection mass flow equal to 1.2% of the core mass flow. Injection near the pylon produced greater broadband shock noise reductions than injection at other locations around the nozzle periphery. Air injection into the core stream did not result in broadband shock noise reduction in dual stream jets. Fluidic injection resulted in some mixing noise reductions for both the single and dual stream jets. For subsonic fan and core conditions, the lowest noise levels were obtained when injecting on the side of the nozzle closest to the microphone axis.

  9. A simple device to convert a small-animal PET scanner into a multi-sample tissue and injection syringe counter.

    PubMed

    Green, Michael V; Seidel, Jurgen; Choyke, Peter L; Jagoda, Elaine M

    2017-10-01

    We describe a simple fixture that can be added to the imaging bed of a small-animal PET scanner that allows for automated counting of multiple organ or tissue samples from mouse-sized animals and counting of injection syringes prior to administration of the radiotracer. The combination of imaging and counting capabilities in the same machine offers advantages in certain experimental settings. A polyethylene block of plastic, sculpted to mate with the animal imaging bed of a small-animal PET scanner, is machined to receive twelve 5-ml containers, each capable of holding an entire organ from a mouse-sized animal. In addition, a triangular cross-section slot is machined down the centerline of the block to secure injection syringes from 1-ml to 3-ml in size. The sample holder is scanned in PET whole-body mode to image all samples or in one bed position to image a filled injection syringe. Total radioactivity in each sample or syringe is determined from the reconstructed images of these objects using volume re-projection of the coronal images and a single region-of-interest for each. We tested the accuracy of this method by comparing PET estimates of sample and syringe activity with well counter and dose calibrator estimates of these same activities. PET and well counting of the same samples gave near identical results (in MBq, R 2 =0.99, slope=0.99, intercept=0.00-MBq). PET syringe and dose calibrator measurements of syringe activity in MBq were also similar (R 2 =0.99, slope=0.99, intercept=- 0.22-MBq). A small-animal PET scanner can be easily converted into a multi-sample and syringe counting device by the addition of a sample block constructed for that purpose. This capability, combined with live animal imaging, can improve efficiency and flexibility in certain experimental settings. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Salicylate-induced changes in spontaneous activity of single units in the inferior colliculus of the guinea pig.

    PubMed

    Jastreboff, P J; Sasaki, C T

    1986-11-01

    Changes in spontaneous neuronal activity of the inferior colliculus in albino guinea pigs before and after administration of sodium salicylate were analyzed. Animals were anesthetized with pentobarbital, and two microelectrodes separated by a few hundred microns were driven through the inferior colliculus. After collecting a sufficiently large sample of cells, sodium salicylate (450 mg/kg) was injected i.p. and recordings again made 2 h after the injection. Comparison of spontaneous activity recorded before and after salicylate administration revealed highly statistically significant differences (p less than 0.001). After salicylate, the mean rate of the cell population increased from 29 to 83 Hz and the median from 26 to 74 Hz. Control experiments in which sodium salicylate was replaced by saline injection revealed no statistically significant differences in cell discharges. Recordings made during the same experiments from lobulus V of the cerebellar vermis revealed no changes in response to salicylate. The observed changes in single-unit activity due to salicylate administration may represent the first systematic evidence of a tinnituslike phenomenon in animals.

  11. Barium selenate supplementation and its effect on intramammary infection in pasture-based dairy cows.

    PubMed

    Ceballos, A; Kruze, J; Barkema, H W; Dohoo, I R; Sanchez, J; Uribe, D; Wichtel, J J; Wittwer, F

    2010-04-01

    A significant proportion of cattle receive inadequate dietary Se because of its low content in soils and pastures of various regions of the world. Several economically important diseases in dairy cows, such as mastitis, have been associated with Se deficiency. The objective of this study was to evaluate the effect of a single injection of a long-acting form of Se at drying off on the risk and incidence rate of new intramammary infections and on milk somatic cell count in the subsequent lactation in pasture-based dairy cows. Forty-nine Chilean Holstein-Friesian cows were fed a diet containing <0.05 mg of Se/kg of ration dry matter. During the dry period, cows were allocated to 1 of 2 groups, a supplemented (n=24) group treated with a single subcutaneous injection of barium selenate 2 mo before calving and a control group (n=25) that remained unsupplemented. Duplicate foremilk samples were aseptically collected within 6 d after calving and every 2 wk until drying-off for bacteriological culture. Milk samples were also collected monthly for somatic cell count evaluation. Blood samples were collected before treatment and at 30, 90, 180, and 270 d after treatment for analysis of blood glutathione peroxidase (GPx) activity. The activity of glutathione peroxidase was higher in supplemented cows 30 d after the injection until the end of the study. The risk and incidence rate of new intramammary infections was not affected by supplementation. A progressive increase in somatic cell count was observed throughout lactation, but there was no effect of supplementation. In conclusion, a one-time injection of barium selenate 2 mo before calving in these pasture-based dairy cows did not affect udder health in the subsequent lactation, indicating that Se basal intake was adequate for preventing subclinical mastitis in pasture-based cows in southern Chile. Copyright (c) 2010 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  12. A Customizable Flow Injection System for Automated, High Throughput, and Time Sensitive Ion Mobility Spectrometry and Mass Spectrometry Measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Orton, Daniel J.; Tfaily, Malak M.; Moore, Ronald J.

    To better understand disease conditions and environmental perturbations, multi-omic studies (i.e. proteomic, lipidomic, metabolomic, etc. analyses) are vastly increasing in popularity. In a multi-omic study, a single sample is typically extracted in multiple ways and numerous analyses are performed using different instruments. Thus, one sample becomes many analyses, making high throughput and reproducible evaluations a necessity. One way to address the numerous samples and varying instrumental conditions is to utilize a flow injection analysis (FIA) system for rapid sample injection. While some FIA systems have been created to address these challenges, many have limitations such as high consumable costs, lowmore » pressure capabilities, limited pressure monitoring and fixed flow rates. To address these limitations, we created an automated, customizable FIA system capable of operating at diverse flow rates (~50 nL/min to 500 µL/min) to accommodate low- and high-flow instrument sources. This system can also operate at varying analytical throughputs from 24 to 1200 samples per day to enable different MS analysis approaches. Applications ranging from native protein analyses to molecular library construction were performed using the FIA system. The results from these studies showed a highly robust platform, providing consistent performance over many days without carryover as long as washing buffers specific to each molecular analysis were utilized.« less

  13. The Efficacy of Cyclic Injection of Bone Morphogenetic Protein-2 in Large-Scale Calvarial Bone Defects.

    PubMed

    Choi, Jin Mi; Jeong, Woo Shik; Park, Eun Jung; Choi, Jong Woo

    2017-03-01

    Bone morphogenetic protein-2 (BMP-2) appears to be one of the most potent growth factors thus far studied. However, recent publications on the clinical application of BMP-2 revealed that its correct control is the paramount issue in clinical practice. For improving BMP-2 delivery, the cyclic administration might be an alternative. Accordingly, the authors cyclically injected BMP-2 in a cyclic injection model of large cranial defects to maintain the proper dosage during the bone healing process. A 10-mm diameter calvarial bone defect was produced using a round drill in 8-week-old Sprague-Dawley rats. Silk-hydroxyapatite scaffolds soaked in the appropriate concentration of BMP-2 were implanted into the defect. The animals were split into 4 single-injection groups and 3 multiple-injection groups; the latter groups received weekly subcutaneous injections of BMP-2 solution (1, 5, and 10 μg/mL) for 4 weeks, whereas the former groups received a single injection of BMP-2 at these concentrations. Each rat underwent computed tomography at 8 weeks. In terms of total volumes of the new bone, the 5 μg/mL multiple-injection BMP-2 group had significantly greater increases in bone volume than the single-injection groups. In terms of bone thickness, the multiple-injection groups had better outcomes than the single-injection groups. Thus, the cyclic injection protocol restored the original thickness without overgrowth. Cyclic injection of BMP-2 permits more accurate dosage control than single injection and improves thickness and dense bone regeneration. Therefore, it may represent a promising approach for future clinical trials. Further investigation using a greater number of animals is required.

  14. Disposition of enrofloxacin and its metabolite ciprofloxacin after intramuscular injection in juvenile Burmese pythons (Python molurus bivittatus).

    PubMed

    Young, L A; Schumacher, J; Papich, M G; Jacobson, E R

    1997-03-01

    Eleven juvenile Burmese pythons (Python molurus bivittatus) weighing 0.75-1.75 kg were randomly divided into two groups. Blood samples were obtained through surgically placed anterior carotid artery cannulas. Six pythons received a single i.m. injection of enrofloxacin at 5 mg/kg. Blood samples were obtained at 0.5, 1, 3, 6, 12, 24, 48, 72, and 96 hr postinjection. A mean (+/- SD) maximal plasma concentration of 1.66 (+/- 0.42) micrograms/ml was measured at 5.75 hr postinjection. The harmonic mean half-life was calculated to be 6.37 hr. The second group of five snakes received enrofloxacin at 5 mg/kg i.m. s.i.d. for 5 days. Blood was collected immediately before each injection and at 6 hr after each injection. Over the 5-day period, there was a stepwise increase in mean trough plasma concentrations of enrofloxacin. Clinically effective peak plasma enrofloxacin concentrations were attained after the first injection but did not significantly increase during the sampling period. Pharmacokinetic data were assessed against minimum inhibitory concentrations of enrofloxacin for Pseudomonas ssp. isolates in snakes obtained from historical data at the Veterinary Medical Teaching Hospital, University of Florida. Enrofloxacin should be administered at 10 mg/kg i.m. every 48 hr when treating Pseudomonas ssp. infections in juvenile Burmese pythons. Treatment of infections of more enrofloxacin-sensitive gram-negative bacteria could be achieved with the administration of an initial i.m. dose of 10 mg/kg followed by 5 mg/kg every 48 hr.

  15. Investigating a potential biological treatment to prevent pathological fractures caused by unicameral bone cysts in children under 8 years.

    PubMed

    Ramos-Pascua, Luis R; Sánchez-Herraéz, Sergio; Casas-Ramos, Paula; Molnar Fuentes, Sebastián; Santos Sánchez, José Ángel

    2014-10-01

    There is no consensus on when and how to treat unicameral bone cysts (UBCs), partly because of a lack of knowledge of the aetiology. To review the different treatment techniques for UBCs and to describe our results with a single injection of autogenous bone marrow (BM) mixed with demineralised bone matrix (DBM) in very young children. We reviewed five patients under the age of 8 years with UBCs treated by percutaneous aspiration and a single injection of BM associated with DBM. The cyst was located in the proximal humerus in four patients and in the proximal femur in one patient. Assessment of the need for surgery was based on the clinical and radiographic suspicion of new pathological fractures. The administration of a second injection, when necessary, was based on the surgeon's judgement regarding the risk of fracture. The mean follow-up after first injection was 41 months. There were no complications related to the procedure, except a non-displaced fracture, which healed without problems. All patients were pain free and progressively resumed their activities without restriction until a new fracture occurred in two cases. According to Capanna's classification, only one case healed completely (grade 1), one lesion was classified as grade 2, and there were three recurrences at 11, 12 and 27 months after initial treatment (grade 3). The final outcome was treatment failure for three out of the five patients. Two patients were treated with a second injection and one patient is waiting for surgery. A single injection of aspirated autogenous BM mixed with DBM in very young children with active UBCs at risk of fracture is very simple, comfortable and safe. Nevertheless, the results seem to be unpredictable and are probably more dependent on the natural evolution of the cyst than on the treatment. Further comparative studies with larger sample numbers are needed.

  16. Safety, pharmacokinetics, and pharmacodynamics of S-(-)-pantoprazole sodium injections after single and multiple intravenous doses in healthy Chinese subjects.

    PubMed

    Jiao, Hui-Wen; Sun, Lu-Ning; Li, Yue-Qi; Yu, Lei; Zhang, Hong-Wen; Wang, Mei-Feng; Yu, Li-Yuan; Yuan, Zi-Qing-Yun; Xie, Li-Jun; Chen, Juan; Meng, Ling; Zhang, Xue-Hui; Wang, Yong-Qing

    2018-03-01

    The objective of this study was to evaluate the safety, pharmacokinetics, and pharmacodynamics of S-(-)-pantoprazole (PPZ) sodium injections following single and multiple intravenous doses in healthy Chinese subjects. The dosage groups were set as followed: 20 mg of single and multiple intravenous administration of S-(-)-PPZ, 40 mg of single and multiple intravenous administration of S-(-)-PPZ or pantoprazole, and 80 mg of single dosage group of S-(-)-PPZ. Subjects were sampled for pharmacokinetic analysis and were monitored for 24-h intragastric pH prior to and 48-h intragastric pH after administration for the pharmacodynamic study. The pharmacokinetic and pharmacodynamic parameters were compared between S-(-)-PPZ and PPZ. Safety was evaluated on the basis of adverse events, vital signs, laboratory tests, and physical examination. All adverse events were mild and of limited duration. Maximum plasma concentration and area under the concentration-time curve for S-(-)-PPZ were dose proportional over the range of 20-80 mg following a single intravenous administration. Elimination rate constant and half-life observed statistical difference from a single dose to multiple doses in 40 mg of S-(-)-PPZ groups. After administration of a single dose, the mean 24-h intragastric pH value was observed higher in 80-mg group than in 40- and 20-mg groups. Slightly increase of intragastric pH was found after a single dose of 40 mg S-(-)-PPZ than 40 mg PPZ; however, the differences were not statistically significant. Twice daily of 40 mg S-(-)-PPZ sodium injections is effective in achieving satisfying acid inhibition. Compared with plasma R-(+)-PPZ levels, most subjects presented more potent and prolonged suppression of gastric acid of S-(-)-PPZ, while a few subjects showed faster metabolic rate of S-(-)-PPZ in vivo.

  17. Comparison of Nerve Stimulation-guided Axillary Brachial Plexus Block, Single Injection versus Four Injections: A Prospective Randomized Double-blind Study.

    PubMed

    Badiger, Santoshi V; Desai, Sameer N

    2017-01-01

    A variety of techniques have been described for the axillary block using nerve stimulator, either with single injection, two, three, or four separate injections. Identification of all the four nerves is more difficult and time-consuming than other methods. Aim of the present study is to compare success rate, onset, and duration of sensory and motor anesthesia of axillary block using nerve stimulator, either with single injection after identification of any one of the four nerves or four separate injections following identification of each of nerve. Prospective, randomized, double-blind study. Patients undergoing forearm and hand surgeries under axillary block. One hundred patients, aged 18-75 years, were randomly allocated into two groups of 50 each. Axillary block was performed under the guidance of nerve stimulator with a mixture of 18 ml of 1.5% lignocaine and 18 ml of 0.5% bupivacaine. In the first group ( n = 50), all 36 ml of local anesthetic was injected after the identification of motor response to any one of the nerves and in Group 2, all the four nerves were identified by the motor response, and 9 ml of local anesthetic was injected at each of the nerves. The success rate of the block, onset, and duration of sensory and motor block was assessed. Categorical variables were compared using the Chi-square test, and continuous variables were compared using independent t -test. The success rate of the block with four injection technique was higher compared to single-injection technique (84% vs. 56%, P = 0.02). Four injection groups had a faster onset of sensory and motor block and prolonged duration of analgesia compared to single-injection group ( P < 0.001). There were no significant differences in the incidence of accidental arterial puncture and hemodynamic parameter between the groups. Identification of all the four nerves produced higher success rate and better quality of the block when compared to single-injection technique.

  18. Rodent CNS neuron development: Timing of cell birth and death

    NASA Technical Reports Server (NTRS)

    Keefe, J. R.

    1984-01-01

    Data obtained from a staged series of single paired injections of tritiated thymidine to pregnant Wistar rats or C57B16/j mice on selected embryonic days and several postnatal times are reported. All injected specimens were allowed to come to term, each litter culled to six pups and specimens were sacrificed on PN28, with fixation and embedding for paraffin and plastic embedding. The results are derived from serial paraffin sections of PN28 animals exposed to autoradiographic processing and plotted with respect to heavily labelled cell nuclei present in the selected brain stem nuclei and sensory ganglia. Counts from each time sample/structure are totalled and the percentage of cells in the total labelled population/structure represented by each injection time interval plotted.

  19. Double-cross hydrostatic pressure sample injection for chip CE: variable sample plug volume and minimum number of electrodes.

    PubMed

    Luo, Yong; Wu, Dapeng; Zeng, Shaojiang; Gai, Hongwei; Long, Zhicheng; Shen, Zheng; Dai, Zhongpeng; Qin, Jianhua; Lin, Bingcheng

    2006-09-01

    A novel sample injection method for chip CE was presented. This injection method uses hydrostatic pressure, generated by emptying the sample waste reservoir, for sample loading and electrokinetic force for dispensing. The injection was performed on a double-cross microchip. One cross, created by the sample and separation channels, is used for formation of a sample plug. Another cross, formed by the sample and controlling channels, is used for plug control. By varying the electric field in the controlling channel, the sample plug volume can be linearly adjusted. Hydrostatic pressure takes advantage of its ease of generation on a microfluidic chip, without any electrode or external pressure pump, thus allowing a sample injection with a minimum number of electrodes. The potential of this injection method was demonstrated by a four-separation-channel chip CE system. In this system, parallel sample separation can be achieved with only two electrodes, which is otherwise impossible with conventional injection methods. Hydrostatic pressure maintains the sample composition during the sample loading, allowing the injection to be free of injection bias.

  20. Study of pore pressure reaction on hydraulic fracturing

    NASA Astrophysics Data System (ADS)

    Trimonova, Mariia; Baryshnikov, Nikolay; Turuntaev, Sergey; Zenchenko, Evgeniy; Zenchenko, Petr

    2017-04-01

    We represent the results of the experimental study of the hydraulic fracture propagation influence on the fluid pore pressure. Initial pore pressure was induced by injection and production wells. The experiments were carried out according to scaling analysis based on the radial model of the fracture. All required geomechanical and hydrodynamical properties of a sample were derived from the scaling laws. So, gypsum was chosen as a sample material and vacuum oil as a fracturing fluid. The laboratory setup allows us to investigate the samples of cylindrical shape. It can be considered as an advantage in comparison with standard cubic samples, because we shouldn't consider the stress field inhomogeneity induced by the corners. Moreover, we can set 3D-loading by this setting. Also the sample diameter is big enough (43cm) for placing several wells: the fracturing well in the center and injection and production wells on two opposite sides of the central well. The experiment consisted of several stages: a) applying the horizontal pressure; b) applying the vertical pressure; c) water solution injection in the injection well with a constant pressure; d) the steady state obtaining; e) the oil injection in the central well with a constant rate. The pore pressure was recorded in the 15 points along bottom side of the sample during the whole experiment. We observe the pore pressure change during all the time of the experiment. First, the pore pressure changed due to water injection. Then we began to inject oil in the central well. We compared the obtained experimental data on the pore pressure changes with the solution of the 2D single-phase equation of pore-elasticity, and we found significant difference. The variation of the equation parameters couldn't help to resolve the discrepancy. After the experiment, we found that oil penetrated into the sample before and after the fracture initiation. This fact encouraged us to consider another physical process - the oil-water displacement. Have taken into account the phenomenon, we could find the parameter values for the best matching the experimental data with the analytical one. After such a comparison, we could estimate the permeability variation in the different directions due to changes in the pore pressure during fracturing. Thus it was found that for the correct solution of hydrodynamic problems in relation with hydraulic fracturing (for example, to estimate the production rate of the fractured well) one should take into account the change of the permeability in the vicinity of the fracture and solve nonlinear pore-elasticity problem.

  1. Electrokinetic supercharging with a system-induced terminator and an optimized capillary versus electrode configuration for parts-per-trillion detection of rare-earth elements in CZE.

    PubMed

    Xu, Zhongqi; Kawahito, Kouji; Ye, Xiaoxue; Timerbaev, Andrei R; Hirokawa, Takeshi

    2011-05-01

    A further improvement of electrokinetic supercharging (EKS) methodology has been proposed, with the objective to enhance the sensitivity of the conventional CZE-UV method down to a single-digit part per trillion (ppt) level. The advanced EKS procedure is based on a novel phenomenon displaying the formation of a zone with an increased concentration of the hydrogen ion, capable to perform the function of a terminator, behind the sample zone upon electrokinetic injection. In combination with a visualizing co-ion of BGE, protonated 4-methylbenzylamine, acting as the leading ion, such system-induced terminator a effected the transient ITP state to efficiently concentrate cationic analytes prior to CZE. Furthermore, to amass more analyte ions within the effective electric field at the injection stage, a standard sample vial was replaced with an elongated vial that allowed the sample volume to be increased from 500 to 900 μL. Alongside, this replacement made the upright distance between the electrode and the capillary tips prolonged to 40.0 mm to achieve high-efficiency electrokinetic injection. The computer simulation was used for profiling analyte concentration, pH, and field strength in order to delineate formation of the terminator during sample injection. The proposed preconcentration strategy afforded an enrichment factor of 80,000 and thereby the LODs of rare-earth metal ions at the ppt level, e.g. 0.04 nM (6.7 ng/L) for erbium(III). Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Acute toxic effects of single dose dacarbazine: hematological and histological changes in an animal model.

    PubMed

    Milijašević, B; Stefanović, D; Lalić-Popović, M; Tomić, Z; Kolarović, J; Lalošević, D; Mikov, M

    2014-11-01

    Treatment of advanced soft tissue sarcoma usually includes dacarbazine (DTIC), an alkylating agent that methylates DNA and is active during all phases of the cell cycle. Common side effects of DTIC include nausea, vomiting, impaired liver and kidney function, myelosuppression, and pneumonia. There are no accounts, however, of histological and hematological changes caused by DTIC. We investigated acute hematological and morphological changes in different organs and in tumors that were caused by a single dose of DTIC. Adult Syrian golden hamsters were inoculated with a suspension of tumorigenic baby hamster kidney (BHK) cells by subcutaneous injection. On day 14 after inoculation, doses of 1.4, 1.6, 1.8 or 2.0 g/m(2) DTIC were injected intraperitoneally into the hamsters. Hamsters in the control group were injected with physiological saline in the same way. Seven days after drug or saline injection the animals were sacrificed and samples of blood, heart, kidney, liver, lungs, spleen, small intestine and tumor were excised, processed and analyzed. Mitoses were counted using an ocular extension with engraved frame. Anemia, thrombocytopenia and leukocytosis were found in the control group of hamsters with fibrosarcoma, whereas animals with fibrosarcoma treated with DTIC developed anemia, thrombocytopenia and leukopenia. Severe pneumonia and moderate hepatitis were detected in all DTIC treated groups. Effects of DTIC on tumor cells included rounding and enlargement of nuclei and rarefaction of chromatin. The number of mitoses was reduced with increasing doses of DTIC. Hepatitis, myelosuppression, pneumonia, and dose-related inhibition of tumor cell proliferation were observed after a single dose of DTIC.

  3. Surface Analysis of Nerve Agent Degradation Products by ...

    EPA Pesticide Factsheets

    Report This sampling and analytical procedure was developed and applied by a single laboratory to investigate nerve agent degradation products, which may persist at a contaminated site, via surface wiping followed by analytical characterization. The performance data presented demonstrate the fitness-for-purpose regarding surface analysis in that single laboratory. Surfaces (laminate, glass, galvanized steel, vinyl tile, painted drywall and treated wood) were wiped with cotton gauze wipes, sonicated, extracted with distilled water, and filtered. Samples were analyzed with direct injection electrospray ionization liquid chromatography tandem mass spectrometry (ESI-LC/MS/MS) without derivatization. Detection limit data were generated for all analytes of interest on a laminate surface. Accuracy and precision data were generated from each surface fortified with these analytes.

  4. Dispersion-convolution model for simulating peaks in a flow injection system.

    PubMed

    Pai, Su-Cheng; Lai, Yee-Hwong; Chiao, Ling-Yun; Yu, Tiing

    2007-01-12

    A dispersion-convolution model is proposed for simulating peak shapes in a single-line flow injection system. It is based on the assumption that an injected sample plug is expanded due to a "bulk" dispersion mechanism along the length coordinate, and that after traveling over a distance or a period of time, the sample zone will develop into a Gaussian-like distribution. This spatial pattern is further transformed to a temporal coordinate by a convolution process, and finally a temporal peak image is generated. The feasibility of the proposed model has been examined by experiments with various coil lengths, sample sizes and pumping rates. An empirical dispersion coefficient (D*) can be estimated by using the observed peak position, height and area (tp*, h* and At*) from a recorder. An empirical temporal shift (Phi*) can be further approximated by Phi*=D*/u2, which becomes an important parameter in the restoration of experimental peaks. Also, the dispersion coefficient can be expressed as a second-order polynomial function of the pumping rate Q, for which D*(Q)=delta0+delta1Q+delta2Q2. The optimal dispersion occurs at a pumping rate of Qopt=sqrt[delta0/delta2]. This explains the interesting "Nike-swoosh" relationship between the peak height and pumping rate. The excellent coherence of theoretical and experimental peak shapes confirms that the temporal distortion effect is the dominating reason to explain the peak asymmetry in flow injection analysis.

  5. Determination of acrylamide in drinking water by large-volume direct injection and ion-exclusion chromatography-mass spectrometry.

    PubMed

    Cavalli, S; Polesello, S; Saccani, G

    2004-06-11

    Acrylamide, a known neurotoxin and putative human carcinogen, has been included among the substances to be monitored in drinking water according to the European Union Directive 98/83 on potable water. This paper reports a new method based on the combination of ion-exclusion chromatographic separation and MS detection. Samples of drinking water have been directly injected in the microbore ICE-AS1 column and detected in the selected-ion monitoring mode by a single quadrupole system with electrospray ionization. Chromatographic conditions, such as eluent composition and flow rate, have been optimized by a central composite design experiment. Statistical analysis of data showed that the amount of acetonitrile fraction in the eluent mixture, composed by acetonitrile and formic acid solution, is the variable that most influences retention of the acrylamide peak. After optimization of MS detection parameters, this method has been validated for spiked drinking water samples. The effect of large-volume injection (up to 500 microl) has been also explored. Linearity was evaluated from 0.5 to 5 microg l(-1). Repeatability, expressed as R.S.D., was 16 and 12% at 0.5 and 1 microg l(-1) respectively. The limit of detection was 0.20 ppb with 500 microl injection volume.

  6. Voltage controlled nano-injection system for single-cell surgery

    PubMed Central

    Seger, R. Adam; Actis, Paolo; Penfold, Catherine; Maalouf, Michelle; Vilozny, Boaz; Pourmand, Nader

    2015-01-01

    Manipulation and analysis of single cells is the next frontier in understanding processes that control the function and fate of cells. Herein we describe a single-cell injection platform based on nanopipettes. The system uses scanning microscopy techniques to detect cell surfaces, and voltage pulses to deliver molecules into individual cells. As a proof of concept, we injected adherent mammalian cells with fluorescent dyes. PMID:22899383

  7. Voltage controlled nano-injection system for single-cell surgery.

    PubMed

    Adam Seger, R; Actis, Paolo; Penfold, Catherine; Maalouf, Michelle; Vilozny, Boaz; Pourmand, Nader

    2012-09-28

    Manipulation and analysis of single cells is the next frontier in understanding processes that control the function and fate of cells. Herein we describe a single-cell injection platform based on nanopipettes. The system uses scanning microscopy techniques to detect cell surfaces, and voltage pulses to deliver molecules into individual cells. As a proof of concept, we injected adherent mammalian cells with fluorescent dyes.

  8. Treatment of testicular hydrocele with tetracycline sclerotherapy.

    PubMed

    Ozkan, S; Bircan, K; Ozen, H

    1990-01-01

    Fifteen patients with primary hydrocele of the testis were treated by aspiration and injection of tetracycline. Only 5 patients (33.3%) were cured by a single injection of tetracycline. Furthermore, 46.6% of our patients experienced severe scrotal pain, three of whom required open surgery. We do not recommend single injection tetracycline therapy, and further injections were not performed due to severe side effects.

  9. [Residues of chloramphenicol in the calf organism following parenteral administration of the Czechoslovak preparation Chronicin inj].

    PubMed

    Malíková, M; Habrda, J

    1976-03-01

    Using two biological methods the chloramphenicol content in various tissues of 11 calves aged 3--18 days was determined after a single-dose therapeutical administration of the Czechoslovak preparation of Chronicin inj. in the quantity of 12 mg kg-1 body mass. Of four test strains, solely Micrococcus flavus (ATCC 10240) strain proved suitable. Chloramphenicol was quantitatively determined by reading from transformed standard curves. An evalua tion of the two approximately equally sensitive methods yielded the following results: three days after the injection all calves were positive, at 5 and 10 days, one of three calves in each group was negativ similarly to both calves slaughtered 15 days post injection. The residues appeared most frequently in the liver, at the site of injection, and in the fore and hind musculature. Maximum detectable concentrations were recorded in the liver. Culinary and technological treatment of positive meat and liver samples revealed that 15 minutes' boiling and 30 minutes' roasting destroyed the microbiologically active chloramphenicol residues in the samples. Neither deep freezing nor salting was sufficient for residue inactivation, although in some samples a decrease in biological chloramphenicol activity by circa 20--30% was recorded. a preslaughter withdrawal time of 15 days is recommended.

  10. Effect of jet injection on infectivity of measles, mumps, and rubella vaccine in a bench model.

    PubMed

    Coughlin, Melissa M; Collins, Marcus; Saxon, Gene; Jarrahian, Courtney; Zehrung, Darin; Cappello, Chris; Dhere, Rajeev; Royals, Michael; Papania, Mark; Rota, Paul A

    2015-08-26

    Disposable-syringe jet injectors (DSJIs) with single-use, auto disable, needle-free syringes offer the opportunity to avoid hazards associated with injection using a needle and syringe. Clinical studies have evaluated DSJIs for vaccine delivery, but most studies have focused on inactivated, subunit, or DNA vaccines. Questions have been raised about possible damage to live attenuated viral vaccines by forces generated during the jet injection process. This study examines the effect of jet injection on the integrity of measles, mumps, and rubella vaccine (MMR), measured by viral RNA content and infectivity. Three models of DSJIs were evaluated, each generating a different ejection force. Following jet injection, the RNA content for each of the vaccine components was measured using RT-qPCR immediately after injection and following passage in Vero cells. Jet injection was performed with and without pig skin as a simulation of human skin. There was little to no reduction of RNA content immediately following jet injection with any of the three DSJIs. Samples passaged in Vero cells showed no loss in infectivity of the measles vaccine following jet injection. Mumps vaccine consistently showed increased replication following jet injection. Rubella vaccine showed no loss after jet injection alone but some infectivity loss following injection through pig skin with two of the devices. Overall, these data demonstrated that forces exerted on a live attenuated MMR vaccine did not compromise vaccine infectivity. The bench model and protocol used in this study can be applied to evaluate the impact of jet injection on other live virus vaccines. Published by Elsevier Ltd.

  11. Single, double or multiple-injection techniques for non-ultrasound guided axillary brachial plexus block in adults undergoing surgery of the lower arm.

    PubMed

    Chin, Ki Jinn; Alakkad, Husni; Cubillos, Javier E

    2013-08-08

    Regional anaesthesia comprising axillary block of the brachial plexus is a common anaesthetic technique for distal upper limb surgery. This is an update of a review first published in 2006 and updated in 2011. To compare the relative effects (benefits and harms) of three injection techniques (single, double and multiple) of axillary block of the brachial plexus for distal upper extremity surgery. We considered these effects primarily in terms of anaesthetic effectiveness; the complication rate (neurological and vascular); and pain and discomfort caused by performance of the block. We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library), MEDLINE, EMBASE and reference lists of trials. We contacted trial authors. The date of the last search was March 2013 (updated from March 2011). We included randomized controlled trials that compared double with single-injection techniques, multiple with single-injection techniques, or multiple with double-injection techniques for axillary block in adults undergoing surgery of the distal upper limb. We excluded trials using ultrasound-guided techniques. Independent study selection, risk of bias assessment and data extraction were performed by at least two investigators. We undertook meta-analysis. The 21 included trials involved a total of 2148 participants who received regional anaesthesia for hand, wrist, forearm or elbow surgery. Risk of bias assessment indicated that trial design and conduct were generally adequate; the most common areas of weakness were in blinding and allocation concealment.Eight trials comparing double versus single injections showed a statistically significant decrease in primary anaesthesia failure (risk ratio (RR 0.51), 95% confidence interval (CI) 0.30 to 0.85). Subgroup analysis by method of nerve location showed that the effect size was greater when neurostimulation was used rather than the transarterial technique.Eight trials comparing multiple with single injections showed a statistically significant decrease in primary anaesthesia failure (RR 0.25, 95% CI 0.14 to 0.44) and of incomplete motor block (RR 0.61, 95% CI 0.39 to 0.96) in the multiple injection group.Eleven trials comparing multiple with double injections showed a statistically significant decrease in primary anaesthesia failure (RR 0.28, 95% CI 0.20 to 0.40) and of incomplete motor block (RR 0.55, 95% CI 0.36 to 0.85) in the multiple injection group.Tourniquet pain was significantly reduced with multiple injections compared with double injections (RR 0.53, 95% CI 0.33 to 0.84). Otherwise there were no statistically significant differences between groups in any of the three comparisons on secondary analgesia failure, complications and patient discomfort. The time for block performance was significantly shorter for single and double injections compared with multiple injections. This review provides evidence that multiple-injection techniques using nerve stimulation for axillary plexus block produce more effective anaesthesia than either double or single-injection techniques. However, there was insufficient evidence for a significant difference in other outcomes, including safety.

  12. Dexamethasone levels and base to apex concentration gradients in scala tympani perilymph following intracochlear delivery in the guinea pig

    PubMed Central

    Hahn, Hartmut; Salt, Alec N.; Biegner, Thorsten; Kammerer, Bernd; Delabar, Ursular; Hartsock, Jared; Plontke, Stefan K.

    2012-01-01

    Hypothesis To determine whether intracochlearly applied dexamethasone will lead to better control of drug levels, higher peak concentrations and lower base-to apex concentration gradients in scala tympani (ST) of the guinea pig than after intratympanic (round window, RW) application. Background Local application of drugs to the RW results in substantial variation of intracochlear drug levels and significant base-to apex concentration gradients in ST. Methods Two μL of dexamethasone-phosphate (10 mg/mL) were injected into ST either through the RW membrane which was covered with 1% sodium hyaluronate gel or through a cochleostomy with a fluid tight seal of the micropipette. Perilymph was sequentially sampled from the apex at a single time point for each animal, at 20, 80, or 200 min after the injection ended. Results were mathematically interpreted by the means of an established computer model and compared with prior experiments performed by our group with the same experimental techniques but using intratympanic applications. Results Single intracochlear injections over 20 min resulted in approximately ten times higher peak concentrations (on average) than 2-3 hours of intratympanic application to the round window niche. Intracochlear drug levels were less variable and could be measured for at least up to 220 min. Concentration gradients along scala tympani were less pronounced. The remaining variability in intracochlear drug levels was attributable to perilymph and drug leak from the injection site. Conclusion With significantly higher, less variable drug levels and smaller base-to apex concentration gradients, intracochlear applications have advantages to intratympanic injections. For further development of this technique, it is of importance to control leaks of perilymph and drug from the injection site and to evaluate its clinical feasibility and associated risks. PMID:22588238

  13. Dexamethasone levels and base-to-apex concentration gradients in the scala tympani perilymph after intracochlear delivery in the guinea pig.

    PubMed

    Hahn, Hartmut; Salt, Alec N; Biegner, Thorsten; Kammerer, Bernd; Delabar, Ursular; Hartsock, Jared J; Plontke, Stefan K

    2012-06-01

    To determine whether intracochlearly applied dexamethasone will lead to better control of drug levels, higher peak concentrations, and lower base-to-apex concentration gradients in the scala tympani (ST) of the guinea pig than after intratympanic (round window [RW]) application. Local application of drugs to the RW results in substantial variation of intracochlear drug levels and significant base-to-apex concentration gradients in ST. Two microliters of dexamethasone-phosphate (10 mg/ml) were injected into ST either through the RW membrane, which was covered with 1% sodium hyaluronate gel or through a cochleostomy with a fluid tight seal of the micropipette. Perilymph was sequentially sampled from the apex at a single time point for each animal, at 20, 80, or 200 min after the injection ended. Results were mathematically interpreted by means of an established computer model and compared with previous experiments performed by our group with the same experimental techniques but using intratympanic applications. Single intracochlear injections of 20 minutes resulted in approximately 10 times higher peak concentrations (on average) than 2 to 3 hours of intratympanic application to the RW niche. Intracochlear drug levels were less variable and could be measured for over 220 minutes. Concentration gradients along the scala tympani were less pronounced. The remaining variability in intracochlear drug levels was attributable to perilymph and drug leak from the injection site. With significantly higher, less variable drug levels and smaller base-to-apex concentration gradients, intracochlear applications have advantages to intratympanic injections. For further development of this technique, it is of importance to control leaks of perilymph and drug from the injection site and to evaluate its clinical feasibility and associated risks.

  14. Automated centrifugal-microfluidic platform for DNA purification using laser burst valve and coriolis effect.

    PubMed

    Choi, Min-Seong; Yoo, Jae-Chern

    2015-04-01

    We report a fully automated DNA purification platform with a micropored membrane in the channel utilizing centrifugal microfluidics on a lab-on-a-disc (LOD). The microfluidic flow in the LOD, into which the reagents are injected for DNA purification, is controlled by a single motor and laser burst valve. The sample and reagents pass successively through the micropored membrane in the channel when each laser burst valve is opened. The Coriolis effect is used by rotating the LOD bi-directionally to increase the purity of the DNA, thereby preventing the mixing of the waste and elution solutions. The total process from the lysed sample injection into the LOD to obtaining the purified DNA was finished within 7 min with only one manual step. The experimental result for Salmonella shows that the proposed microfluidic platform is comparable to the existing devices in terms of the purity and yield of DNA.

  15. Stability of Dalteparin 1,000 Unit/mL in 0.9% Sodium Chloride for Injection in Polypropylene Syringes.

    PubMed

    Kirkham, Kylian; Munson, Jessica M; McCluskey, Susan V; Graner, Kevin K

    2017-01-01

    The stability of dalteparin 1,000 units/mL in 0.9% sodium chloride for injection stored in polypropylene syringes under refrigeration was examined. Dalteparin 1,000-units/mL syringes were prepared by adding 9 mL of 0.9% sodium chloride for injection to 1 mL of dalteparin sodium 10,000 unit/mL from commercial single-use syringes. Compounded solutions in 0.5-mL aliquots were transferred to 1-mL polypropylene syringes and sealed with a Luer lock tip cap and stored at refrigerated temperatures (2°C to 8°C) with ambient fluorescent light exposure. Syringes from three batches of dalteparin 1,000 units/mL were potency tested in duplicate by a stability-indicating high-performance liquid chromatography assay using a 0.5-mL sample at specified intervals. Visual and pH testing were performed on each batch. Samples were visually inspected for container integrity, color, and clarity. Samples for pH testing were prepared using a 1:1 dilution of dalteparin 1,000 units/mL in sterile water for injection and underwent duplicate analysis at each time point. High-performance liquid chromatography analyses showed a remaining percent of the initial dalteparin content at day 30 of 94.88% ± 2.11%. Samples remained colorless and clear with no signs of container compromise and no visual particulate matter at each time point. Throughout the 30-day study period, pH values remained within 0.3-pH units from the initial value of 5.84. Dalteparin 1,000 unit/mL in 0.9% sodium chloride for injection, packaged in 1-mL polypropylene syringes was stable for at least 30 days while stored at refrigerated conditions with ambient fluorescent light exposure. Copyright© by International Journal of Pharmaceutical Compounding, Inc.

  16. Seroprevalence of influenza A H1N1 and seroconversion of mothers and infants induced by a single dose of monovalent vaccine.

    PubMed

    Chao, Anne; Huang, Yhu-Chering; Chang, Yao-Lung; Wang, Tzu-Hao; Chang, Shuenn-Dyh; Wu, Ting-Shu; Wu, Tsu-Lan; Chao, An-Shine

    2013-09-01

    To determine the prevalence of preexisting antibodies against the pandemic 2009 Influenza A (H1N1) virus in pregnant women and to evaluate the seroprotection of the mothers and infants by a single injection of monovalent vaccine during the pandemic. Seropositivity rate of H1N1 among the nonvaccinated were compared with the vaccinated women. A single dose of vaccine, either nonadjuvanted AdimFlu-S or MF59-adjuvanted vaccine, was injected to the voluntarily vaccinated group. Maternal and cord blood sera were collected to evaluate the antibody response of the H1N1 virus. Seropositivity was defined as a hemagglutination inhibition titer to H1N1 (A/Taiwan/126/09) ≥ 1:40. A total of 210 healthy, singleton, pregnant women were enrolled between January 2010 and May 2010. Seropositivity (≥ 1:40) of maternal hemagglutination inhibition was significantly higher in the vaccinated group (78%) than the nonvaccinated group (9.5%); 41.6% (20/48) of seropositive titers were >1:80. In nine vaccinated cases resulting in negative serum titers (<1:40), the prevalence of negative titer in the women received AdimFlu-S (14.8%, 4/31) was lower (p = 0.025) than those received MF59-adjuvanted vaccine (50%, 5/10). Subclinical infection against H1N1 was low in Taiwanese pregnant women in the pandemic 2009. Seropositivity >75% could be achieved in the paired maternal and cord serum samples by a single injection of monovalent H1N1 vaccine. Copyright © 2013. Published by Elsevier B.V.

  17. An automated single ion hit at JAERI heavy ion microbeam to observe individual radiation damage

    NASA Astrophysics Data System (ADS)

    Kamiya, Tomihiro; Sakai, Takuro; Naitoh, Yutaka; Hamano, Tsuyoshi; Hirao, Toshio

    1999-10-01

    Microbeam scanning and a single ion hit technique have been combined to establish an automated beam positioning and single ion hit system at the JAERI Takasaki heavy ion microbeam system. Single ion irradiation on preset points of a sample in various patterns can be performed automatically in a short period. The reliability of the system was demonstrated using CR-39 nuclear track detectors. Single ion hit patterns were achieved with a positioning accuracy of 2 μm or less. In measurement of single event transient current using this system, the reduction of the pulse height by accumulation of radiation damages was observed by single ion injection to the same local areas. This technique showed a possibility to get some quantitative information about the lateral displacement of an individual radiation effect in silicon PIN photodiodes. This paper will give details of the irradiation system and present results from several experiments.

  18. Single mimivirus particles intercepted and imaged with an X-ray laser

    PubMed Central

    Seibert, M. Marvin; Ekeberg, Tomas; Maia, Filipe R. N. C.; Svenda, Martin; Andreasson, Jakob; Jönsson, Olof; Odić, Duško; Iwan, Bianca; Rocker, Andrea; Westphal, Daniel; Hantke, Max; DePonte, Daniel P.; Barty, Anton; Schulz, Joachim; Gumprecht, Lars; Coppola, Nicola; Aquila, Andrew; Liang, Mengning; White, Thomas A.; Martin, Andrew; Caleman, Carl; Stern, Stephan; Abergel, Chantal; Seltzer, Virginie; Claverie, Jean-Michel; Bostedt, Christoph; Bozek, John D.; Boutet, Sébastien; Miahnahri, A. Alan; Messerschmidt, Marc; Krzywinski, Jacek; Williams, Garth; Hodgson, Keith O.; Bogan, Michael J.; Hampton, Christina Y.; Sierra, Raymond G.; Starodub, Dmitri; Andersson, Inger; Bajt, Saša; Barthelmess, Miriam; Spence, John C. H.; Fromme, Petra; Weierstall, Uwe; Kirian, Richard; Hunter, Mark; Doak, R. Bruce; Marchesini, Stefano; Hau-Riege, Stefan P.; Frank, Matthias; Shoeman, Robert L.; Lomb, Lukas; Epp, Sascha W.; Hartmann, Robert; Rolles, Daniel; Rudenko, Artem; Schmidt, Carlo; Foucar, Lutz; Kimmel, Nils; Holl, Peter; Rudek, Benedikt; Erk, Benjamin; Hömke, André; Reich, Christian; Pietschner, Daniel; Weidenspointner, Georg; Strüder, Lothar; Hauser, Günter; Gorke, Hubert; Ullrich, Joachim; Schlichting, Ilme; Herrmann, Sven; Schaller, Gerhard; Schopper, Florian; Soltau, Heike; Kühnel, Kai-Uwe; Andritschke, Robert; Schröter, Claus-Dieter; Krasniqi, Faton; Bott, Mario; Schorb, Sebastian; Rupp, Daniela; Adolph, Marcus; Gorkhover, Tais; Hirsemann, Helmut; Potdevin, Guillaume; Graafsma, Heinz; Nilsson, Björn; Chapman, Henry N.; Hajdu, Janos

    2014-01-01

    X-ray lasers offer new capabilities in understanding the structure of biological systems, complex materials and matter under extreme conditions1–4. Very short and extremely bright, coherent X-ray pulses can be used to outrun key damage processes and obtain a single diffraction pattern from a large macromolecule, a virus or a cell before the sample explodes and turns into plasma1. The continuous diffraction pattern of non-crystalline objects permits oversampling and direct phase retrieval2. Here we show that high-quality diffraction data can be obtained with a single X-ray pulse from a non-crystalline biological sample, a single mimivirus particle, which was injected into the pulsed beam of a hard-X-ray free-electron laser, the Linac Coherent Light Source5. Calculations indicate that the energy deposited into the virus by the pulse heated the particle to over 100,000 K after the pulse had left the sample. The reconstructed exit wavefront (image) yielded 32-nm full-period resolution in a single exposure and showed no measurable damage. The reconstruction indicates inhomogeneous arrangement of dense material inside the virion. We expect that significantly higher resolutions will be achieved in such experiments with shorter and brighter photon pulses focused to a smaller area. The resolution in such experiments can be further extended for samples available in multiple identical copies. PMID:21293374

  19. Relative Bioavailability of a Single 4-mg Dose of Somatropin Administered by Subcutaneous Injection or by Needle-free Device and Coadministered With the Growth Hormone Inhibitor Octreotide Acetate in Healthy Adult Subjects.

    PubMed

    Brimhall, Darin B; Petri, Niclas; D'Angelo, Pina

    2018-05-01

    Somatropin, used to treat growth hormone deficiency, has been traditionally administered by subcutaneous (SC) injection with needle and syringe. Needle-free devices offer ease of administration and may improve adherence and outcomes. This study evaluated the relative bioavailability of somatropin delivered with a needle-free device compared with traditional SC injection. In this randomized, single-dose, crossover study, healthy adults aged 18 to 35 years received single 4-mg doses of somatropin via a needle-free device or SC injection, along with octreotide to suppress endogenous growth hormone production. Blood samples were analyzed for serum somatropin and insulin-like growth factor-1 (IGF-1) concentrations over 24 hours after somatropin dosing. Pharmacokinetic and pharmacodynamic parameters were evaluated by using noncompartmental methods, and bioequivalence was determined based on ln transformation of the AUC 0-24 , AUC 0-∞ , C max , area under the effect-time curve from time 0 to 24 hours (AUEC 0-24 ), and maximum effect concentration (E max ). Bioequivalence was concluded if the 90% CIs of the needle-free device compared with the SC injection, constructed by using the two 1-sided hypotheses at the α = 0.05 level, for these pharmacokinetic/pharmacodynamic parameters fell within the 80.00% to125.00% regulatory acceptance range. A total of 57 subjects completed both study periods and were included in the pharmacokinetic analyses. Point estimates (90% CIs) of the geometric mean ratio (needle-free device/SC injection) based on serum somatropin were 1.013 (0.987-1.040) for AUC 0-24 , 1.012 (0.986-1.038) for AUC 0-∞ , and 1.200 (1.137-1.267) for C max . For IGF-1, baseline-corrected point estimates (90% CIs) were 0.901 (0.818-0.993) for AUEC 0-24 and 0.867 (0.795-0.946) for E max . Non-baseline-corrected values were 0.978 (0.953-1.004) for AUEC 0-24 and 0.953 (0.923-0.984) for E max . Both treatments were well tolerated; blood glucose levels increased in nearly all subjects (98.3%). All adverse events were mild and resolved spontaneously within 24 hours. Bioequivalence was shown for a single 4-mg dose of somatropin delivered by using a needle-free device compared with SC injection based on ln-transformed AUC 0-24 and AUC 0-∞ but not ln-transformed C max . Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.

  20. Pharmacokinetics of betamethasone after single-dose intramuscular administration of betamethasone phosphate and betamethasone acetate to healthy subjects.

    PubMed

    Salem, Isam I; Najib, Naji M

    2012-01-01

    Betamethasone is used for its antiinflammatory and immunosuppressive effects in disorders of many organ systems. However, the pharmacokinetic properties of betamethasone in plasma after intramuscular injection of betamethasone sodium phosphate and betamethasone acetate dual-acting suspension need further investigation. The main aim of this study was to determine the pharmacokinetic parameters of betamethasone, betamethasone acetate, and betamethasone phosphate after the administration of a single intramuscular dose of the dual-acting suspension to healthy human volunteers. Two different studies were conducted in healthy males. Volunteers were judged healthy based on their medical history, physical examination, and laboratory test results. Before confinement, all volunteers were tested for freedom from alcohol and drugs of abuse. Following a 10-hour overnight fasting, a single dose of 1 mL of the dual-acting suspension containing 3 mg of betamethasone phosphate and 3 mg of betamethasone acetate was administered by intramuscular injection. Blood sampling covered 48 hours. The plasma samples obtained in the second study were stabilized to enable pharmacokinetic profiling of betamethasone esters. Twenty-four healthy males with mean (SD) age of 27 (6.62) years participated in each study. No incidences of serious adverse events were recorded during the studies. Six mild adverse events were reported in 2 subjects in the second study. One subject suffered from pain at the injection site and insomnia, and another subject complained of heartburn and drowsiness. Betamethasone phosphate appeared to be readily absorbed with a mean AUC(0-t) of 96.01 ng/h/mL and an AUC(0-∞) of 97.96 (23.38) ng/h/mL. Betamethasone peak plasma concentration reached a mean t(½) of 12.92 hours. Betamethasone acetate was not detected in the volunteers' plasma in either study (total of 2208 plasma samples). The observed pharmacokinetic parameters suggested that the acetate ester, and not the phosphate ester, of betamethasone acts as a prodrug or reservoir for betamethasone, conferring on it sustained- and extended-release characteristics. Copyright © 2012 Elsevier HS Journals, Inc. All rights reserved.

  1. Quantitative analysis of fragrance in selectable one dimensional or two dimensional gas chromatography-mass spectrometry with simultaneous detection of multiple detectors in single injection.

    PubMed

    Tan, Hui Peng; Wan, Tow Shi; Min, Christina Liew Shu; Osborne, Murray; Ng, Khim Hui

    2014-03-14

    A selectable one-dimensional ((1)D) or two-dimensional ((2)D) gas chromatography-mass spectrometry (GC-MS) system coupled with flame ionization detector (FID) and olfactory detection port (ODP) was employed in this study to analyze perfume oil and fragrance in shower gel. A split/splitless (SSL) injector and a programmable temperature vaporization (PTV) injector are connected via a 2-way splitter of capillary flow technology (CFT) in this selectable (1)D/(2)D GC-MS/FID/ODP system to facilitate liquid sample injections and thermal desorption (TD) for stir bar sorptive extraction (SBSE) technique, respectively. The dual-linked injectors set-up enable the use of two different injector ports (one at a time) in single sequence run without having to relocate the (1)D capillary column from one inlet to another. Target analytes were separated in (1)D GC-MS/FID/ODP and followed by further separation of co-elution mixture from (1)D in (2)D GC-MS/FID/ODP in single injection without any instrumental reconfiguration. A (1)D/(2)D quantitative analysis method was developed and validated for its repeatability - tR; calculated linear retention indices (LRI); response ratio in both MS and FID signal, limit of detection (LOD), limit of quantitation (LOQ), as well as linearity over a concentration range. The method was successfully applied in quantitative analysis of perfume solution at different concentration level (RSD≤0.01%, n=5) and shower gel spiked with perfume at different dosages (RSD≤0.04%, n=5) with good recovery (96-103% for SSL injection; 94-107% for stir bar sorptive extraction-thermal desorption (SBSE-TD). Copyright © 2014 Elsevier B.V. All rights reserved.

  2. Strength and Deformation Behaviour of Cap Rocks Above the CO2SINK-Reservoir

    NASA Astrophysics Data System (ADS)

    Mutschler, T.; Triantafyllidis, T.; Balthasar, K.; Norden, B.

    2009-04-01

    The cap-rock of the CO2SINK storage site close to Ketzin consists of clay rich rocks which are typical for cap rock formations above CO2 storage reservoirs. The strength and deformation behaviour of such claystone samples are therefore of fundamental importance for the characterization of secure geological storage of CO2. The elastic and anelastic deformation behaviour limits the maximum injection pressure during CO2-injection and is part of the security measures for the long term storage of CO2. The laboratory experiments where performed on samples gathered from the injection well of the Ketzin pilot test site in Germany and are compared with the elastic and anelastic behaviour of samples from the same Keuper formation in a near-surface outcrop in the Southwest of Germany showing a similar lithology. The samples from the outcrop allowed drilling of samples with a standard size of 100 mm diameter and 200 mm height as well as large samples with a diameter of 550 mm and a height of 1200 mm. The investigations have a special emphasis on the viscous behaviour of the clay stones and its scaling behaviour. A special triaxial testing procedure is applied both on standard and large size samples allowing the determination of the strength, stiffness and viscosity behaviour of the rock in one experimental run. Multi-stage technique (stepwise variation of the confining pressure) gives the strength behaviour of each single sample while applying a constant deformation rate. Stepwise varied deformation rates on the other hand lead to steps in the stress-strain-curve from which the viscosity index is determined. The viscosity index is directly used in the Norton's constitutive relations for viscoplastic simulations. The combination of tests allows for the determination of a broad range of elastic and anelastic properties. The comparison of results - both for elastic and anelastic behaviour - from standard and large samples shows that for the examined rocks a scale effect is negligible. Transition from cataclastic to non-cataclastic behaviour - the transition limit - occurs in a similar range of applied levels of pressure and deformation rates even at room temperature. The obtained transition limit is very important for the judgment of the sealing capacity and integrity of the cap rock. The deformation rates predicted for the pressure and temperature conditions of the caprock at Ketzin test site are far beneath the determined transition limit during the injection and after stop of injection. As a 0° friction angle is used for pressure and deformation limit at Ketzin, the measured elastic and anelastic behaviour of the real caprock act as additional safety margin during injection and in the post injection phase. As the examined rocks are typical for many possible storage sites, the discussed results are of importance beyond the Ketzin Pilot Experiment CO2SINK.

  3. Numerical simulation based on core analysis of a single fracture in an Enhanced Geothermal System

    NASA Astrophysics Data System (ADS)

    Jarrahi, Miad; Holländer, Hartmut

    2017-04-01

    The permeability of reservoirs is widely affected by the presence of fractures dispersed within them, as they form superior paths for fluid flow. Core analysis studies the fractures characteristics and explains the fluid-rock interactions to provide the information of permeability and saturation of a hydraulic fracturing reservoir or an enhanced geothermal system (EGS). This study conducted numerical simulations of a single fracture in a Granite core obtained from a depth of 1890 m in borehole EPS1 from Soultz-sous-Forêts, France. Blaisonneau et al. (2016) designed the apparatus to investigate the complex physical phenomena on this cylindrical sample. The method of the tests was to percolate a fluid through a natural fracture contained in a rock sample, under controlled thermo-hydro-mechanical conditions. A divergent radial flow within the fracture occurred due to the injection of fluid into the center of the fracture. The tests were performed within a containment cell with a normal stress of 2.6, 4.9, 7.2 and 9.4 MPa loading on the sample perpendicular to the fracture plane. This experiment was numerically performed to provide an efficient numerical method by modeling single phase flow in between the fracture walls. Detailed morphological features of the fracture such as tortuosity and roughness, were obtained by image processing. The results included injection pressure plots with respect to injection flow rate. Consequently, by utilizing Hagen-Poiseuille's cubic law, the equivalent hydraulic aperture size, of the fracture was derived. Then, as the sample is cylindrical, to modify the Hagen-Poiseuille's cubic law for circular parallel plates, the geometric relation was applied to obtain modified hydraulic aperture size. Finally, intrinsic permeability of the fracture under each mechanical normal stress was evaluated based on modified hydraulic aperture size. The results were presented in two different scenarios, before and after reactive percolation test, to demonstrate the effect of chemical reactive flow. The fracture after percolation test showed larger equivalent aperture size and higher permeability. Additionally, the higher the normal stress, the lower permeability was investigated. This confirmed the permeability evolution due to chemical percolation and mechanical loading. All results showed good agreements with corresponding experimental results provided by Blaisonneau et al. (2016). Keyword: Core analysis, Hydraulic fracturing, Enhanced geothermal system, Permeability, Fluid-rock interactions.

  4. Improved hydrostatic pressure sample injection by tilting the microchip towards the disposable miniaturized CE device.

    PubMed

    Wang, Wei; Zhou, Fang; Zhao, Liang; Zhang, Jian-Rong; Zhu, Jun-Jie

    2008-02-01

    A simple method of hydrostatic pressure sample injection towards a disposable microchip CE device was developed. The liquid level in the sample reservoir was higher than that in the sample waste reservoir (SWR) by tilting microchip and hydrostatic pressure was generated, the sample was driven to pass through injection channel into SWR. After sample loading, the microchip was levelled for separation under applied high separation voltage. Effects of tilted angle, initial liquid height and injection duration on electrophoresis were investigated. With enough injection duration, the injection result was little affected by tilted angle and initial liquid heights in the reservoirs. Injection duration for obtaining a stable sample plug was mainly dependent on the tilted angle rather than the initial height of liquid. Experimental results were consistent with theoretical prediction. Fluorescence observation and electrochemical detection of dopamine and catechol were employed to verify the feasibility of tilted microchip hydrostatic pressure injection. Good reproducibility of this injection method was obtained. Because the instrumentation was simplified and no additional hardware was needed in this technology, the proposed method would be potentially useful in disposable devices.

  5. Characterization of quantum interference control of injected currents in LT-GaAs for carrier-envelope phase measurements.

    PubMed

    Roos, Peter; Quraishi, Qudsia; Cundiff, Steven; Bhat, Ravi; Sipe, J

    2003-08-25

    We use two mutually coherent, harmonically related pulse trains to experimentally characterize quantum interference control (QIC) of injected currents in low-temperature-grown gallium arsenide. We observe real-time QIC interference fringes, optimize the QIC signal fidelity, uncover critical signal dependences regarding beam spatial position on the sample, measure signal dependences on the fundamental and second harmonic average optical powers, and demonstrate signal characteristics that depend on the focused beam spot sizes. Following directly from our motivation for this study, we propose an initial experiment to measure and ultimately control the carrier-envelope phase evolution of a single octave-spanning pulse train using the QIC phenomenon.

  6. Proposal for Microwave Boson Sampling.

    PubMed

    Peropadre, Borja; Guerreschi, Gian Giacomo; Huh, Joonsuk; Aspuru-Guzik, Alán

    2016-09-30

    Boson sampling, the task of sampling the probability distribution of photons at the output of a photonic network, is believed to be hard for any classical device. Unlike other models of quantum computation that require thousands of qubits to outperform classical computers, boson sampling requires only a handful of single photons. However, a scalable implementation of boson sampling is missing. Here, we show how superconducting circuits provide such platform. Our proposal differs radically from traditional quantum-optical implementations: rather than injecting photons in waveguides, making them pass through optical elements like phase shifters and beam splitters, and finally detecting their output mode, we prepare the required multiphoton input state in a superconducting resonator array, control its dynamics via tunable and dispersive interactions, and measure it with nondemolition techniques.

  7. The effects of a single intravenous injection of novel activin A/BMP-2 (AB204) on toxicity and the respiratory and central nervous systems

    PubMed Central

    Yoon, Byung-Hak; Lee, Jae Hyup; Na, Kyuheum; Ahn, Chihoon; Cho, Jongho; Ahn, Hyun Chan; Choi, Jungyoun; Oh, Hyosun; Kim, Byong Moon; Choe, Senyon

    2018-01-01

    The purpose of this study was to determine the effects of a single intravenous injection of a novel osteoinductive material, activin A/BMP-2 (AB204), to rodents on toxicity and their respiratory functions and central nervous system (CNS). A single intravenous injection of AB204 was given to Sprague–Dawley (SD) rats in doses of 0, 0.625, 2.5 and 10 mg/kg to observe the mortality rate, the general symptoms for 14 days. The experimental groups were also given 0.2, 0.4 and 0.8 mg/kg of AB204, respectively, and the respiration rate, the tidal volume and the minute volume were measured for 240 min. The experimental groups of imprinting control region (ICR) mice were given a single intravenous injection of 0.2, 0.4 and 0.8 mg/kg of AB204, respectively. Their body temperature was taken and general behaviors were observed to evaluate the effect of AB204 on the CNS for 240 min. The study on toxicity of a single intravenous injection found no death or abnormal symptoms, abnormal findings from autopsy, or abnormal body weight gain or loss in all the experimental groups. No abnormal variation associated with the test substance was observed in the respiration rate, the tidal volume, the minute volume, body temperature or the general behaviors. On the basis of these results, the approximate lethal dose of AB204 for a single intravenous injection exceeds 10 mg/kg for SD rats and a single intravenous injection of ≤0.8 mg/kg AB204 has no effect on their respiratory system for SD rat and no effect on their CNS for ICR mice. PMID:26446865

  8. The effects of a single intravenous injection of novel activin A/BMP-2 (AB204) on toxicity and the respiratory and central nervous systems.

    PubMed

    Yoon, Byung-Hak; Lee, Jae Hyup; Na, Kyuheum; Ahn, Chihoon; Cho, Jongho; Ahn, Hyun Chan; Choi, Jungyoun; Oh, Hyosun; Kim, Byong Moon; Choe, Senyon

    2016-01-01

    The purpose of this study was to determine the effects of a single intravenous injection of a novel osteoinductive material, activin A/BMP-2 (AB204), to rodents on toxicity and their respiratory functions and central nervous system (CNS). A single intravenous injection of AB204 was given to Sprague-Dawley (SD) rats in doses of 0, 0.625, 2.5 and 10 mg/kg to observe the mortality rate, the general symptoms for 14 days. The experimental groups were also given 0.2, 0.4 and 0.8 mg/kg of AB204, respectively, and the respiration rate, the tidal volume and the minute volume were measured for 240 min. The experimental groups of imprinting control region (ICR) mice were given a single intravenous injection of 0.2, 0.4 and 0.8 mg/kg of AB204, respectively. Their body temperature was taken and general behaviors were observed to evaluate the effect of AB204 on the CNS for 240 min. The study on toxicity of a single intravenous injection found no death or abnormal symptoms, abnormal findings from autopsy, or abnormal body weight gain or loss in all the experimental groups. No abnormal variation associated with the test substance was observed in the respiration rate, the tidal volume, the minute volume, body temperature or the general behaviors. On the basis of these results, the approximate lethal dose of AB204 for a single intravenous injection exceeds 10 mg/kg for SD rats and a single intravenous injection of ≤0.8 mg/kg AB204 has no effect on their respiratory system for SD rat and no effect on their CNS for ICR mice.

  9. Effects of Multiple Intra-articular Injections of 0.5% Bupivacaine on Normal and Osteoarthritic Joints in Rats.

    PubMed

    Iwasaki, Koji; Sudo, Hideki; Kasahara, Yasuhiko; Yamada, Katsuhisa; Ohnishi, Takashi; Tsujimoto, Takeru; Iwasaki, Norimasa

    2016-10-01

    To determine the in vivo effects of multiple local anesthetic injections of 0.5% bupivacaine on normal and osteoarthritic articular cartilage. Rats with normal knee joints received an intra-articular injection of 0.9% saline solution or 0.5% bupivacaine in their right knees joint once a week for 5 consecutive weeks, starting 4 weeks after the beginning of the experiment. Rats were humanely killed at 8, 16, and 24 weeks. In a parallel experiment, rats underwent anterior cruciate ligament transection to induce osteoarthritic changes. These rats were subjected to the same protocol as those with normal knee joints, starting 4 weeks after the procedure. Static weight-bearing tests were performed on both hind limbs to evaluate changes in weight-bearing ability throughout the experiments. Rats were humanely killed at 8 and 16 weeks. Cell viability was assessed with confocal microscopy, using samples from the distal femur. Histologic assessment of osteoarthritis was performed using samples from the tibial plateau based on the Osteoarthritis Research Society International (OARSI) cartilage histopathology assessment system (i.e., OARSI score). Static weight-bearing tests showed no significant changes after intra-articular injection of saline solution or bupivacaine, and bupivacaine injection did not increase weight bearing compared with saline solution injection, regardless of whether there were osteoarthritic changes. There were also no significant differences in cell viability, cell density, or OARSI scores between the saline solution and bupivacaine groups at each time point, regardless of whether osteoarthritic changes were induced. This study suggested that single or intermittent intra-articular bupivacaine injections might not have deleterious effects on either osteoarthritic or normal joints. There is no strong evidence that intra-articular bupivacaine injection induces degenerative changes in articular cartilage. Therefore, these results may apply to normal and osteoarthritic joints. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  10. Effect of muscle activity immediately after botulinum toxin injection for writer's cramp.

    PubMed

    Chen, R; Karp, B I; Goldstein, S R; Bara-Jimenez, W; Yaseen, Z; Hallett, M

    1999-03-01

    Animal and human studies have shown that nerve stimulation enhances some effects of botulinum toxin (btx A) injection. Voluntary muscle activity might work similarly and would focus the effect of an injection into the active muscles. We studied the effects of exercise immediately after btx A injection in eight patients with writer's cramp with established response to btx A over two injection cycles with a single-blinded, randomized, crossover design. Immediately after the first study injection, they were randomly assigned to write continuously for 30 min or have their hand and forearm immobilized for 30 min. Following the second injection, they were assigned the alternate condition. Patients were assessed just before each injection, and at 2 weeks, 6 weeks, and 3 months post-injection. Assessment included objective strength testing, self-reported rating of benefit and weakness, and blinded evaluation of videotapes and writing samples of the patients writing a standard passage. Strength testing showed that the maximum weakness occurred at 2 weeks post-injection, but the benefit was maximum at 6 weeks post-injection. The "write" condition resulted in greater reduction in strength than the "rest" condition. Btx A treatment led to improvement in self-reported ratings, writer's cramp rating scale scores by blinded raters, and reduction in writing time, but the differences between the "write" and "rest" conditions were not significant. We conclude that voluntary muscle activity immediately after btx A injection leads to greater reduction in muscle strength. Our findings raise the possibility that voluntary muscle activation may allow reduction of btx A doses and favorably alter the balance of benefit and side effects of btx A injections.

  11. Single-element optical injection locking of diode-laser arrays

    DOEpatents

    Hadley, G. Ronald; Hohimer, John P.; Owyoung, Adelbert

    1988-01-01

    By optically injecting a single end-element of a semiconductor laser array, both the spatial and spectral emission characteristics of the entire laser array is controlled. With the output of the array locked, the far-field emission angle of the array is continuously scanned over several degrees by varying the injection frequency.

  12. The effect of the hole injection layer on the performance of single layer organic light-emitting diodes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wenjin, Zeng; Ran, Bi; Hongmei, Zhang, E-mail: iamhmzhang@njupt.edu.cn, E-mail: iamwhuang@njupt.edu.cn

    2014-12-14

    Efficient single-layer organic light-emitting diodes (OLEDs) were reported based on a green fluorescent dye 10-(2-benzothiazolyl)-2,3,6,7-tetrahydro-1,1,7,7–tetramethyl-1H,5H,11H-(1) benzopyropyrano (6,7-8-I,j)quinolizin-11-one (C545T). Herein, poly(3,4-ethylenedioxy thiophene) poly(styrene sulfonate) were, respectively, applied as the injection layer for comparison. The hole transport properties of the emission layer with different hole injection materials are well investigated via current-voltage measurement. It was clearly found that the hole injection layers (HILs) play an important role in the adjustment of the electron/hole injection to attain transport balance of charge carriers in the single emission layer of OLEDs with electron-transporting host. The layer of tris-(8-hydroxyquinoline) aluminum played a dual role of hostmore » and electron-transporting materials within the emission layer. Therefore, appropriate selection of hole injection layer is a key factor to achieve high efficiency OLEDs with single emission layer.« less

  13. Ultrasound-Guided Single-Injection Infraclavicular Block Versus Ultrasound-Guided Double-Injection Axillary Block: A Noninferiority Randomized Controlled Trial.

    PubMed

    Boivin, Ariane; Nadeau, Marie-Josée; Dion, Nicolas; Lévesque, Simon; Nicole, Pierre C; Turgeon, Alexis F

    2016-01-01

    Single-injection ultrasound-guided infraclavicular block is a simple, reliable, and effective technique. A simplified double-injection ultrasound-guided axillary block technique with a high success rate recently has been described. It has the advantage of being performed in a superficial and compressible location, with a potentially improved safety profile. However, its effectiveness in comparison with single-injection infraclavicular block has not been established. We hypothesized that the double-injection ultrasound-guided axillary block would show rates of complete sensory block at 30 minutes noninferior to the single-injection ultrasound-guided infraclavicular block. After approval by our research ethics committee and written informed consent, adults undergoing distal upper arm surgery were randomized to either group I, ultrasound-guided single-injection infraclavicular block, or group A, ultrasound-guided double-injection axillary block. In group I, 30 mL of 1.5% mepivacaine was injected posterior to the axillary artery. In group A, 25 mL of 1.5% mepivacaine was injected posteromedial to the axillary artery, after which 5 mL was injected around the musculocutaneous nerve. Primary outcome was the rate of complete sensory block at 30 minutes. Secondary outcomes were the onset of sensory and motor blocks, surgical success rates, performance times, and incidence of complications. All outcomes were assessed by a blinded investigator. The noninferiority of the double-injection ultrasound-guided axillary block was considered if the limits of the 90% confidence intervals (CIs) were within a 10% margin of the rate of complete sensory block of the infraclavicular block. At 30 minutes, the rate of complete sensory block was 79% in group A (90% CI, 71%-85%) compared with 91% in group I (90% CI, 85%-95%); the upper limit of CI of group A is thus included in the established noninferiority margin of 10%. The rate of complete sensory block was lower in group A (proportion difference of 12% [95% CI, 2-22]; P = 0.0091), as was surgical success rate (82% [95% CI, 74%-89%] vs 93% [95% CI, 86%-97%]; proportion difference of 11% [95% CI 1-20]; P = 0.0153). Sensory block onset also was slower in group A (log rank test P = 0.0020). Performance times were faster in group I (231 seconds [95% CI, 213-250]) than in group A (358 seconds [95% CI, 332-387]; P < 0.0001). No statistically significant difference was observed for vascular puncture, paresthesia during block performance, or procedure-related pain. No neurologic complication was noted at follow-up. We failed to demonstrate that the rate of complete sensory block of the double-injection axillary block is noninferior to the single-injection infraclavicular block. However, the rate of complete sensory block at 30 minutes is statistically significantly lower with the axillary block. The ultrasound-guided single-injection infraclavicular block thus seems to be the preferred technique over the axillary for upper arm anesthesia.

  14. Women's injection drug practices in their own words: a qualitative study.

    PubMed

    Tuchman, Ellen

    2015-03-07

    There are significant gender differences in injection drug practices and relative risks involved for women who inject drug compared with men. This qualitative study aims to explore the social, contextual, and behavioral dimensions of injecting practices among women who inject drugs. Participants were selected by purposive venue-based sampling from a syringe exchange program in 2012-2013. In-depth interviews were conducted with 26 women to elicit detailed perspectives regarding injection drug use practices and women-focused decision-making. All interviews were transcribed verbatim and analyzed with Atlas.ti. Participant's mean age was 43.2 years, 48% Caucasian, 36% African American, and 16% Latina, poorly educated, mostly single, and heroin self-injectors. Three themes emerged; a) transitioning from non-injection to injection drug use; b) patterns and variations of initiation to injecting; and c) shifting toward autonomy or reliance on others. Women were predominantly influenced to transition to injection drug use by other women with their claims that injecting was a way to curtail their daily drug expenditure. More than half the women received their first injection from another woman in their social network rather than a male sexual partner. Self-injecting women exhibited agency around the circumstances of injection safety and potential risks. Other women revealed that their inability to inject themselves could and did make them dependent on others for unsafe injection practices. The finding that many women were influenced to transition to injection drug use and receive the first injection from a woman is contrary to literature claims that male sexual partners introduce and initiate women to injection drug use. Self-injecting women possessed capacity to act in a way that produced the results they wanted, not sharing prepared drugs or injecting equipment. In stark contrast, women assisted with injections could and did make them vulnerable to unsafe injecting. Findings support early prevention strategies that discourage women's transition from non-injection to injection and development of female peer-driven experiential interventions to dispel myths for non-injection women and to increase personal capability to self-inject for women who require assistance with injecting, to reduce injection-related harm.

  15. Single-pass BPM system of the Photon Factory storage ring.

    PubMed

    Honda, T; Katoh, M; Mitsuhashi, T; Ueda, A; Tadano, M; Kobayashi, Y

    1998-05-01

    At the 2.5 GeV ring of the Photon Factory, a single-pass beam-position monitor (BPM) system is being prepared for the storage ring and the beam transport line. In the storage ring, the injected beam position during the first several turns can be measured with a single injection pulse. The BPM system has an adequate performance, useful for the commissioning of the new low-emittance lattice. Several stripline BPMs are being installed in the beam transport line. The continuous monitoring of the orbit in the beam transport line will be useful for the stabilization of the injection energy as well as the injection beam orbit.

  16. Effects of artificial infection of Litopenaeus vannamei by Micrococcus lysodeikticus and WSSV on the activity of immunity related enzymes.

    PubMed

    Sun, Cheng-Bo; Wang, Gang; Chan, Siuming F

    2015-10-01

    In this study, the activities of 5 immunity related enzymes namely acid phosphatase (ACP), alkaline phosphatase (AKP), phenoloxidase (PO), peroxidase (POD) and lysozyme phosphatase (LZM)) of Litopenaeus vannamei after they have been injected with different concentrations of Micrococcus lysodeikticus and the white spot syndrome virus (WSSV) were examined. The cumulative mortality at 0, 24, 48, 72, 96 h was obtained. Copy numbers of WSSV in L. vannamei after a single infection, secondary infection and concurrent infection were measured. Hemolymph samples of M. lysodeikticus and WSSV injected shrimp were collected at 0, 6, 12 24, 48, 72, 78, 84, 96 and 120 h. The results were: (i) The cumulative mortality of L. vannamei increased as the shrimp were infected with higher concentration of the bacteria; (ii) The most sensitive changes of ACP, AKP and LZM were in the 6.2 × 10(5), 6.2 × 10(6), 6.2 × 10(7) cfu/mL M. lysodeikticus group; (iii) ACP but LZM were more sensitive to M. lysodeikticus than WSSV, and AKP, PO and POD is more sensitive to WSSV; (iv) The copies of WSSV in the co-injected group were higher than WSSV-single infection and WSSV-bacteria-secondary infection group at 48 h. The amount of WSSV in L. vannamei of concurrent infection and WSSV-bacteria-secondary infection groups were higher than that of the WSSV-single infection group. Copyright © 2015. Published by Elsevier Ltd.

  17. Feasibility study of TSPO quantification with [18F]FEPPA using population-based input function.

    PubMed

    Mabrouk, Rostom; Strafella, Antonio P; Knezevic, Dunja; Ghadery, Christine; Mizrahi, Romina; Gharehgazlou, Avideh; Koshimori, Yuko; Houle, Sylvain; Rusjan, Pablo

    2017-01-01

    The input function (IF) is a core element in the quantification of Translocator protein 18 kDa with positron emission tomography (PET), as no suitable reference region with negligible binding has been identified. Arterial blood sampling is indeed needed to create the IF (ASIF). In the present manuscript we study individualization of a population based input function (PBIF) with a single arterial manual sample to estimate total distribution volume (VT) for [18F]FEPPA and to replicate previously published clinical studies in which the ASIF was used. The data of 3 previous [18F]FEPPA studies (39 of healthy controls (HC), 16 patients with Parkinson's disease (PD) and 18 with Alzheimer's disease (AD)) was reanalyzed with the new approach. PBIF was used with the Logan graphical analysis (GA) neglecting the vascular contribution to estimate VT. Time of linearization of the GA was determined with the maximum error criteria. The optimal calibration of the PBIF was determined based on the area under the curve (AUC) of the IF and the agreement range of VT between methods. The shape of the IF between groups was studied while taking into account genotyping of the polymorphism (rs6971). PBIF scaled with a single value of activity due to unmetabolized radioligand in arterial plasma, calculated as the average of a sample taken at 60 min and a sample taken at 90 min post-injection, yielded a good interval of agreement between methods and optimized the area under the curve of IF. In HC, gray matter VTs estimated by PBIF highly correlated with those using the standard method (r2 = 0.82, p = 0.0001). Bland-Altman plots revealed PBIF slightly underestimates (~1 mL/cm3) VT calculated by ASIF (including a vascular contribution). It was verified that the AUC of the ASIF were independent of genotype and disease (HC, PD, and AD). Previous clinical results were replicated using PBIF but with lower statistical power. A single arterial blood sample taken 75 minute post-injection contains enough information to individualize the IF in the groups of subjects studied; however, the higher variability produced requires an increase in sample size to reach the same effect size.

  18. Research in the Optical Sciences

    DTIC Science & Technology

    1994-02-01

    Gain Asymmetry and the Generation of New Frequencies2 "’ When a stable coherent beam is injected into a VCSEL that is lasing just above threshold, we... optical microscope was developed and tested. High quality single-crystal layers of beryllium were grown on germanium by molecular beam epitaxy (MBE... OPTICAL ELEWENTS FOR X-UV WAVELENGTHS FALCO AND SLAUGHTEM indicate an increase in crystalline quality as T is increased. However, samples deposited at

  19. Spectral interferometry for morphological imaging in in vitro fertilization (IVF) (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Zhu, Yizheng; Li, Chengshuai

    2016-03-01

    Morphological assessment of spermatozoa is of critical importance for in vitro fertilization (IVF), especially intracytoplasmic sperm injection (ICSI)-based IVF. In ICSI, a single sperm cell is selected and injected into an egg to achieve fertilization. The quality of the sperm cell is found to be highly correlated to IVF success. Sperm morphology, such as shape, head birefringence and motility, among others, are typically evaluated under a microscope. Current observation relies on conventional techniques such as differential interference contrast microscopy and polarized light microscopy. Their qualitative nature, however, limits the ability to provide accurate quantitative analysis. Here, we demonstrate quantitative morphological measurement of sperm cells using two types of spectral interferometric techniques, namely spectral modulation interferometry and spectral multiplexing interferometry. Both are based on spectral-domain low coherence interferometry, which is known for its exquisite phase determination ability. While spectral modulation interferometry encodes sample phase in a single spectrum, spectral multiplexing interferometry does so for sample birefringence. Therefore they are capable of highly sensitive phase and birefringence imaging. These features suit well in the imaging of live sperm cells, which are small, dynamic objects with only low to moderate levels of phase and birefringence contrast. We will introduce the operation of both techniques and demonstrate their application to measuring the phase and birefringence morphology of sperm cells.

  20. Injection System for Multi-Well Injection Using a Single Pump

    PubMed Central

    Wovkulich, Karen; Stute, Martin; Protus, Thomas J.; Mailloux, Brian J.; Chillrud, Steven N.

    2015-01-01

    Many hydrological and geochemical studies rely on data resulting from injection of tracers and chemicals into groundwater wells. The even distribution of liquids to multiple injection points can be challenging or expensive, especially when using multiple pumps. An injection system was designed using one chemical metering pump to evenly distribute the desired influent simultaneously to 15 individual injection points through an injection manifold. The system was constructed with only one metal part contacting the fluid due to the low pH of the injection solutions. The injection manifold system was used during a three-month pilot scale injection experiment at the Vineland Chemical Company Superfund site. During the two injection phases of the experiment (Phase I = 0.27 L/min total flow, Phase II = 0.56 L/min total flow), flow measurements were made 20 times over three months; an even distribution of flow to each injection well was maintained (RSD <4%). This durable system is expandable to at least 16 injection points and should be adaptable to other injection experiments that require distribution of air-stable liquids to multiple injection points with a single pump. PMID:26140014

  1. Triamcinolone hexacetonide protects against fibrillation and osteophyte formation following chemically induced articular cartilage damage.

    PubMed

    Williams, J M; Brandt, K D

    1985-11-01

    Although corticosteroids have been shown to cause articular cartilage degeneration, recent studies of experimentally induced osteoarthritis indicate that under certain conditions they may protect against cartilage damage and osteophyte formation. The present study examines the in vivo effect of triamcinolone hexacetonide on the degeneration of articular cartilage which occurs following intraarticular injection of sodium iodoacetate. Three weeks after a single injection of iodoacetate into the knees of guinea pigs, ipsilateral femoral condylar cartilage exhibited fibrillation, loss of staining with Safranin O, depletion of chondrocytes, and prominent osteophytes. In striking contrast, when triamcinolone hexacetonide was injected into the ipsilateral knee 24 hours after the intraarticular injection of iodoacetate, fibrillation was noted in only 1 of 6 samples, osteophytes were much less prominent, pericellular staining with Safranin O persisted, and cell loss was less extensive. Knees of animals which received only one-tenth as much intraarticular triamcinolone hexacetonide after the iodoacetate injection also exhibited marked reduction in size and extent of osteophytes. However, the degree of fibrillation, loss of Safranin O staining, and chondrocyte depletion was similar to that observed in animals injected with iodoacetate but not treated with intraarticular steroid. No apparent morphologic or histochemical changes were observed after intraarticular injection of the steroid preparation alone. Thus, triamcinolone hexacetonide produced a marked, dose-dependent protective effect in this model of chemically induced articular cartilage damage.

  2. Effects of Pre and Post-Rigor Marinade Injection on Some Quality Parameters of Longissimus Dorsi Muscles

    PubMed Central

    Fadıloğlu, Eylem Ezgi; Serdaroğlu, Meltem

    2018-01-01

    Abstract This study was conducted to evaluate the effects of pre and post-rigor marinade injections on some quality parameters of Longissimus dorsi (LD) muscles. Three marinade formulations were prepared with 2% NaCl, 2% NaCl+0.5 M lactic acid and 2% NaCl+0.5 M sodium lactate. In this study marinade uptake, pH, free water, cooking loss, drip loss and color properties were analyzed. Injection time had significant effect on marinade uptake levels of samples. Regardless of marinate formulation, marinade uptake of pre-rigor samples injected with marinade solutions were higher than post rigor samples. Injection of sodium lactate increased pH values of samples whereas lactic acid injection decreased pH. Marinade treatment and storage period had significant effect on cooking loss. At each evaluation period interaction between marinade treatment and injection time showed different effect on free water content. Storage period and marinade application had significant effect on drip loss values. Drip loss in all samples increased during the storage. During all storage days, lowest CIE L* value was found in pre-rigor samples injected with sodium lactate. Lactic acid injection caused color fade in pre-rigor and post-rigor samples. Interaction between marinade treatment and storage period was found statistically significant (p<0.05). At day 0 and 3, the lowest CIE b* values obtained pre-rigor samples injected with sodium lactate and there were no differences were found in other samples. At day 6, no significant differences were found in CIE b* values of all samples. PMID:29805282

  3. Effects of Pre and Post-Rigor Marinade Injection on Some Quality Parameters of Longissimus Dorsi Muscles.

    PubMed

    Fadıloğlu, Eylem Ezgi; Serdaroğlu, Meltem

    2018-04-01

    This study was conducted to evaluate the effects of pre and post-rigor marinade injections on some quality parameters of Longissimus dorsi (LD) muscles. Three marinade formulations were prepared with 2% NaCl, 2% NaCl+0.5 M lactic acid and 2% NaCl+0.5 M sodium lactate. In this study marinade uptake, pH, free water, cooking loss, drip loss and color properties were analyzed. Injection time had significant effect on marinade uptake levels of samples. Regardless of marinate formulation, marinade uptake of pre-rigor samples injected with marinade solutions were higher than post rigor samples. Injection of sodium lactate increased pH values of samples whereas lactic acid injection decreased pH. Marinade treatment and storage period had significant effect on cooking loss. At each evaluation period interaction between marinade treatment and injection time showed different effect on free water content. Storage period and marinade application had significant effect on drip loss values. Drip loss in all samples increased during the storage. During all storage days, lowest CIE L* value was found in pre-rigor samples injected with sodium lactate. Lactic acid injection caused color fade in pre-rigor and post-rigor samples. Interaction between marinade treatment and storage period was found statistically significant ( p <0.05). At day 0 and 3, the lowest CIE b* values obtained pre-rigor samples injected with sodium lactate and there were no differences were found in other samples. At day 6, no significant differences were found in CIE b* values of all samples.

  4. Quality Assessment of Kumu Injection, a Traditional Chinese Medicine Preparation, Using HPLC Combined with Chemometric Methods and Qualitative and Quantitative Analysis of Multiple Alkaloids by Single Marker.

    PubMed

    Wang, Ning; Li, Zhi-Yong; Zheng, Xiao-Li; Li, Qiao; Yang, Xin; Xu, Hui

    2018-04-09

    Kumu injection (KMI) is a common-used traditional Chinese medicine (TCM) preparation made from Picrasma quassioides (D. Don) Benn. rich in alkaloids. An innovative technique for quality assessment of KMI was developed using high performance liquid chromatography (HPLC) combined with chemometric methods and qualitative and quantitative analysis of multi-components by single marker (QAMS). Nigakinone (PQ-6, 5-hydroxy-4-methoxycanthin-6-one), one of the most abundant alkaloids responsible for the major pharmacological activities of Kumu, was used as a reference substance. Six alkaloids in KMI were quantified, including 6-hydroxy- β -carboline-1-carboxylic acid (PQ-1), 4,5-dimethoxycanthin-6-one (PQ-2), β -carboline-1-carboxylic acid (PQ-3), β -carboline-1-propanoic acid (PQ-4), 3-methylcanthin-5,6-dione (PQ-5), and PQ-6. Based on the outcomes of twenty batches of KMI samples, the contents of six alkaloids were used for further chemometric analysis. By hierarchical cluster analysis (HCA), radar plots, and principal component analysis (PCA), all the KMI samples could be categorized into three groups, which were closely related to production date and indicated the crucial influence of herbal raw material on end products of KMI. QAMS combined with chemometric analysis could accurately measure and clearly distinguish the different quality samples of KMI. Hence, QAMS is a feasible and promising method for the quality control of KMI.

  5. The contribution of lubricant to the formation of particulate matter with reactivity controlled compression ignition in light-duty diesel engines

    DOE PAGES

    Storey, John Morse; Curran, Scott; Dempsey, Adam B.; ...

    2014-12-25

    Reactivity controlled compression ignition (RCCI) has been shown in single- and multi-cylinder engine research to achieve high thermal efficiencies with ultra-low NO X and soot emissions. The nature of the particulate matter (PM) produced by RCCI operation has been shown in recent research to be different than that of conventional diesel combustion and even diesel low-temperature combustion. Previous research has shown that the PM from RCCI operation contains a large amount of organic material that is volatile and semi-volatile. However, it is unclear if the organic compounds are stemming from fuel or lubricant oil. The PM emissions from dual-fuel RCCImore » were investigated in this study using two engine platforms, with an emphasis on the potential contribution of lubricant. Both engine platforms used the same base General Motors (GM) 1.9-L diesel engine geometry. The first study was conducted on a single-cylinder research engine with primary reference fuels (PRFs), n-heptane, and iso-octane. The second study was conducted on a four-cylinder GM 1.9-L ZDTH engine which was modified with a port fuel injection (PFI) system while maintaining the stock direct injection fuel system. Multi-cylinder RCCI experiments were run with PFI gasoline and direct injection of 2-ethylhexyl nitrate (EHN) mixed with gasoline at 5 % EHN by volume. In addition, comparison cases of conventional diesel combustion (CDC) were performed. Particulate size distributions were measured, and PM filter samples were collected for analysis of lube oil components. Triplicate PM filter samples (i.e., three individual filter samples) for both gas chromatography-mass spectroscopy (GC-MS; organic) analysis and X-ray fluorescence (XRF; metals) were obtained at each operating point and queued for analysis of both organic species and lubricant metals. Here, the results give a clear indication that lubricants do not contribute significantly to the formation of RCCI PM.« less

  6. Single Cell Transfection through Precise Microinjection with Quantitatively Controlled Injection Volumes

    NASA Astrophysics Data System (ADS)

    Chow, Yu Ting; Chen, Shuxun; Wang, Ran; Liu, Chichi; Kong, Chi-Wing; Li, Ronald A.; Cheng, Shuk Han; Sun, Dong

    2016-04-01

    Cell transfection is a technique wherein foreign genetic molecules are delivered into cells. To elucidate distinct responses during cell genetic modification, methods to achieve transfection at the single-cell level are of great value. Herein, we developed an automated micropipette-based quantitative microinjection technology that can deliver precise amounts of materials into cells. The developed microinjection system achieved precise single-cell microinjection by pre-patterning cells in an array and controlling the amount of substance delivered based on injection pressure and time. The precision of the proposed injection technique was examined by comparing the fluorescence intensities of fluorescent dye droplets with a standard concentration and water droplets with a known injection amount of the dye in oil. Injection of synthetic modified mRNA (modRNA) encoding green fluorescence proteins or a cocktail of plasmids encoding green and red fluorescence proteins into human foreskin fibroblast cells demonstrated that the resulting green fluorescence intensity or green/red fluorescence intensity ratio were well correlated with the amount of genetic material injected into the cells. Single-cell transfection via the developed microinjection technique will be of particular use in cases where cell transfection is challenging and genetically modified of selected cells are desired.

  7. Analysis of pulsed injection for microgravity receiver tank chilldown

    NASA Astrophysics Data System (ADS)

    Honkonen, Scott C.; Pietrzyk, Joe R.; Schuster, John R.

    The dominant heat transfer mechanism during the hold phase of a tank chilldown cycle in a low-gravity environment is due to fluid motion persistence following the charge. As compared to the single-charge per vent cycle case, pulsed injection maintains fluid motion and the associated high wall heat transfer coefficients during the hold phase. As a result, the pulsed injection procedure appears to be an attractive method for reducing the time and liquid mass required to chill a tank. However, for the representative conditions considered, no significant benefit can be realized by using pulsed injection as compared to the single-charge case. A numerical model of the charge/hold/vent process was used to evaluate the pulsed injection procedure for tank chilldown in microgravity. Pulsed injection results in higher average wall heat transfer coefficients during the hold, as compared to the single-charge case. However, these high levels were not coincident with the maximum wall-to-fluid temperature differences, as in the single-charge case. For representative conditions investigated, the charge/hold/vent process is very efficient. A slightly shorter chilldown time was realized by increasing the number of pulses.

  8. Single Cell Transfection through Precise Microinjection with Quantitatively Controlled Injection Volumes.

    PubMed

    Chow, Yu Ting; Chen, Shuxun; Wang, Ran; Liu, Chichi; Kong, Chi-Wing; Li, Ronald A; Cheng, Shuk Han; Sun, Dong

    2016-04-12

    Cell transfection is a technique wherein foreign genetic molecules are delivered into cells. To elucidate distinct responses during cell genetic modification, methods to achieve transfection at the single-cell level are of great value. Herein, we developed an automated micropipette-based quantitative microinjection technology that can deliver precise amounts of materials into cells. The developed microinjection system achieved precise single-cell microinjection by pre-patterning cells in an array and controlling the amount of substance delivered based on injection pressure and time. The precision of the proposed injection technique was examined by comparing the fluorescence intensities of fluorescent dye droplets with a standard concentration and water droplets with a known injection amount of the dye in oil. Injection of synthetic modified mRNA (modRNA) encoding green fluorescence proteins or a cocktail of plasmids encoding green and red fluorescence proteins into human foreskin fibroblast cells demonstrated that the resulting green fluorescence intensity or green/red fluorescence intensity ratio were well correlated with the amount of genetic material injected into the cells. Single-cell transfection via the developed microinjection technique will be of particular use in cases where cell transfection is challenging and genetically modified of selected cells are desired.

  9. Corticosteroid and Anesthetic Injections for Muscle Strains and Ligament Sprains in the NFL.

    PubMed

    Drakos, Mark; Birmingham, Patrick; Delos, Demetris; Barnes, Ronnie; Murphy, Conor; Weiss, Leigh; Warren, Russell

    2014-07-01

    Administering local anesthetic or corticosteroid injections in professional athletes to allow return to play is common but has traditionally been viewed as suspect and taboo. The skepticism surrounding therapeutic injections stems predominantly from anecdotal experience as opposed to scientific data. The purpose of this paper is to evaluate the current use of corticosteroid injections for muscle strains and ligaments sprains in the National Football League to document player's ability to return to play and possible adverse effects. Athletes from a single National Football League team who received at least one corticosteroid or anesthetic injection for either a muscle strain or ligament sprain during three consecutive seasons were retrospectively reviewed. Thirty-seven injections were given over the three seasons. Injections were either performed blindly or by using ultrasound guidance. Twice as many defensive players were injected than offensive players. The average number of days of conservative treatment before injection was 6.5 days. All players returned to play after injection. There were no complications from any of the injections. Seventeen (55%) players did not miss a single game, and nine (30%) did not miss a single day. Quadriceps strains were associated with the most missed games (four) and the most missed days (36.5). Proximal hamstring strains were second with an average of three missed games and 28 missed days. Corticosteroid injections are a safe and effective therapeutic intervention for treating muscle strains and ligament sprains in order to enable athletes to return to competition earlier.

  10. Injection of demineralized bone matrix with bone marrow concentrate improves healing in unicameral bone cyst.

    PubMed

    Di Bella, Claudia; Dozza, Barbara; Frisoni, Tommaso; Cevolani, Luca; Donati, Davide

    2010-11-01

    Unicameral bone cysts are benign lesions that usually spontaneously regress with skeletal maturity; however, the high risk of pathologic fractures often justifies treatment that could reinforce a weakened bone cortex. Various treatments have been proposed but there is no consensus regarding the best procedure. We compared the healing rates and failures of two methods of cure based on multiple injections of corticosteroid or a single injection of demineralized bone matrix (DBM) in association with bone marrow concentrate (BMC). We retrospectively reviewed 184 patients who had one of the two treatments for unicameral bone cysts with cortical erosion. Clinical records were reviewed for treatment failures and radiographs for healing in all patients. The minimum followup was 12 months for the Steroids Group (mean, 48 months; range, 12-120 months) and 12 months for the DBM + BMC Group (mean, 20 months; range, 12-28 months). After one treatment we observed a lower healing rate of cysts treated with multiple injections of steroids compared with the healing after the first injection of DBM + BMC (21% versus 58%, respectively). At last followup, 38% healed with steroids and 71% with DBM + BMC. The rate of failure after one steroid injection was higher than after a single injection of BDM + BMC (63% versus 24%, respectively). We observed no difference in fracture rates after treatment between the two groups. A single injection of DBM added with autologous bone marrow concentrate appears to provide a higher healing rate with a lower number of failures compared with a single injection of steroids.

  11. Single well surfactant test to evaluate surfactant floods using multi tracer method

    DOEpatents

    Sheely, Clyde Q.

    1979-01-01

    Data useful for evaluating the effectiveness of or designing an enhanced recovery process said process involving mobilizing and moving hydrocarbons through a hydrocarbon bearing subterranean formation from an injection well to a production well by injecting a mobilizing fluid into the injection well, comprising (a) determining hydrocarbon saturation in a volume in the formation near a well bore penetrating formation, (b) injecting sufficient mobilizing fluid to mobilize and move hydrocarbons from a volume in the formation near the well bore, and (c) determining the hydrocarbon saturation in a volume including at least a part of the volume of (b) by an improved single well surfactant method comprising injecting 2 or more slugs of water containing the primary tracer separated by water slugs containing no primary tracer. Alternatively, the plurality of ester tracers can be injected in a single slug said tracers penetrating varying distances into the formation wherein the esters have different partition coefficients and essentially equal reaction times. The single well tracer method employed is disclosed in U.S. Pat. No. 3,623,842. This method designated the single well surfactant test (SWST) is useful for evaluating the effect of surfactant floods, polymer floods, carbon dioxide floods, micellar floods, caustic floods and the like in subterranean formations in much less time and at much reduced cost compared to conventional multiwell pilot tests.

  12. Petrophysical characterization of first ever drilled core samples from an active CO2 storage site, the German Ketzin Pilot Site - Comparison with long term experiments

    NASA Astrophysics Data System (ADS)

    Zemke, Kornelia; Liebscher, Axel

    2014-05-01

    Petrophysical properties like porosity and permeability are key parameters for a safe long-term storage of CO2 but also for the injection operation itself. These parameters may change during and/or after the CO2 injection due to geochemical reactions in the reservoir system that are triggered by the injected CO2. Here we present petrophysical data of first ever drilled cores from a newly drilled well at the active CO2 storage site - the Ketzin pilot site in the Federal State of Brandenburg, Germany. By comparison with pre-injection baseline data from core samples recovered prior to injection, the new samples provide the unique opportunity to evaluate the impact of CO2 on pore size related properties of reservoir and cap rocks at a real injection site under in-situ reservoir conditions. After injection of 61 000 tons CO2, an additional well was drilled and new rock cores were recovered. In total 100 core samples from the reservoir and the overlaying caprock were investigated by NMR relaxation. Permeability of 20 core samples was estimated by nitrogen and porosity by helium pycnometry. The determined data are comparable between pre-injection and post-injection core samples. The lower part of the reservoir sandstone is unaffected by the injected CO2. The upper part of the reservoir sandstone shows consistently slightly lower NMR porosity and permeability values in the post-injection samples when compared to the pre-injection data. This upper sandstone part is above the fluid level and CO2 present as a free gas phase and a possible residual gas saturation of the cores distorted the NMR results. The potash-containing drilling fluid can also influence these results: NMR investigation of twin samples from inner and outer parts of the cores show a reduced fraction of larger pores for the outer core samples together with lower porosities and T2 times. The drill mud penetration depth can be controlled by the added fluorescent tracer. Due to the heterogeneous character of the Stuttgart Formation it is difficult to estimate definite CO2 induced changes from petrophysical measurements. The observed changes are only minor. Several batch experiments on Ketzin samples drilled prior injection confirm the results from investigation of the in-situ rock cores. Core samples of the pre-injection wells were exposed to CO2 and brine in autoclaves over various time periods. Samples were characterized prior to and after the experiments by NMR and Mercury Injection Porosimetry (MIP). The results are consistent with the logging data and show only minor change. Unfortunately, also in these experiments observed mineralogical and petrophysical changes were within the natural heterogeneity of the Ketzin reservoir and precluded unequivocal conclusions. However, given the only minor differences between post-injection well and pre-injection well, it is reasonable to assume that the potential dissolution-precipitation processes appear to have no severe consequences on reservoir and cap rock integrity or on the injection behaviour. This is also in line with the continuously recorded injection operation parameter. These do not point to any changes in reservoir injectivity.|

  13. Imaging single cells in a beam of live cyanobacteria with an X-ray laser (CXIDB ID 26)

    DOE Data Explorer

    Schot, Gijs, vander

    2015-02-10

    This entry contains ten diffraction patterns, and reconstructions images, of individual living Cyanobium gracile cells, imaged using 517 eV X-rays from the LCLS XFEL. The Hawk software package was used for phasing. The Uppsala aerosol injector was used for sample injection, assuring very low noise levels. The cells come from various stages of the cell cycle, and were imaged in random orientations.

  14. Enhancement of high-resolution photoacoustic imaging with indocyanine green-conjugated carbon nanotubes

    NASA Astrophysics Data System (ADS)

    Phuc Nguyen, Van; Oh, Yunok; Ha, Kanglyeol; Oh, Junghwan; Kang, Hyun Wook

    2015-07-01

    The current study indicates the feasibility of photoacoustic imaging (PAI) enhanced with contrast agents. A single-element ultrasound transducer (20 MHz) was used to detect PA signals for image reconstruction. To improve PA sensitivity, single-walled carbon nanotubes (SWNTs) conjugated with indocyanine green (ICG) were injected into samples at various concentrations. PA signal amplitudes linearly increased with SWNT-ICG concentration owing to strong light absorption. Compared with SWNTs, SWNT-ICG augmented the signal intensity by approximately 2-fold (concentration: 300 nM). The enhanced optical absorption can allow the application of SWNT-ICG to enable PAI for specifically identifying tumors with high sensitivity.

  15. Respondent-driven sampling and the recruitment of people with small injecting networks.

    PubMed

    Paquette, Dana; Bryant, Joanne; de Wit, John

    2012-05-01

    Respondent-driven sampling (RDS) is a form of chain-referral sampling, similar to snowball sampling, which was developed to reach hidden populations such as people who inject drugs (PWID). RDS is said to reach members of a hidden population that may not be accessible through other sampling methods. However, less attention has been paid as to whether there are segments of the population that are more likely to be missed by RDS. This study examined the ability of RDS to capture people with small injecting networks. A study of PWID, using RDS, was conducted in 2009 in Sydney, Australia. The size of participants' injecting networks was examined by recruitment chain and wave. Participants' injecting network characteristics were compared to those of participants from a separate pharmacy-based study. A logistic regression analysis was conducted to examine the characteristics independently associated with having small injecting networks, using the combined RDS and pharmacy-based samples. In comparison with the pharmacy-recruited participants, RDS participants were almost 80% less likely to have small injecting networks, after adjusting for other variables. RDS participants were also more likely to have their injecting networks form a larger proportion of those in their social networks, and to have acquaintances as part of their injecting networks. Compared to those with larger injecting networks, individuals with small injecting networks were equally likely to engage in receptive sharing of injecting equipment, but less likely to have had contact with prevention services. These findings suggest that those with small injecting networks are an important group to recruit, and that RDS is less likely to capture these individuals.

  16. Automated on-line renewable solid-phase extraction-liquid chromatography exploiting multisyringe flow injection-bead injection lab-on-valve analysis.

    PubMed

    Quintana, José Benito; Miró, Manuel; Estela, José Manuel; Cerdà, Víctor

    2006-04-15

    In this paper, the third generation of flow injection analysis, also named the lab-on-valve (LOV) approach, is proposed for the first time as a front end to high-performance liquid chromatography (HPLC) for on-line solid-phase extraction (SPE) sample processing by exploiting the bead injection (BI) concept. The proposed microanalytical system based on discontinuous programmable flow features automated packing (and withdrawal after single use) of a small amount of sorbent (<5 mg) into the microconduits of the flow network and quantitative elution of sorbed species into a narrow band (150 microL of 95% MeOH). The hyphenation of multisyringe flow injection analysis (MSFIA) with BI-LOV prior to HPLC analysis is utilized for on-line postextraction treatment to ensure chemical compatibility between the eluate medium and the initial HPLC gradient conditions. This circumvents the band-broadening effect commonly observed in conventional on-line SPE-based sample processors due to the low eluting strength of the mobile phase. The potential of the novel MSFI-BI-LOV hyphenation for on-line handling of complex environmental and biological samples prior to reversed-phase chromatographic separations was assessed for the expeditious determination of five acidic pharmaceutical residues (viz., ketoprofen, naproxen, bezafibrate, diclofenac, and ibuprofen) and one metabolite (viz., salicylic acid) in surface water, urban wastewater, and urine. To this end, the copolymeric divinylbenzene-co-n-vinylpyrrolidone beads (Oasis HLB) were utilized as renewable sorptive entities in the micromachined unit. The automated analytical method features relative recovery percentages of >88%, limits of detection within the range 0.02-0.67 ng mL(-1), and coefficients of variation <11% for the column renewable mode and gives rise to a drastic reduction in operation costs ( approximately 25-fold) as compared to on-line column switching systems.

  17. Design of the Indian NCA study (Indian national collaboration on AIDS): a cluster randomized trial to evaluate the effectiveness of integrated care centers to improve HIV outcomes among men who have sex with men and persons who inject drugs in India.

    PubMed

    Solomon, Sunil S; Lucas, Gregory M; Celentano, David D; McFall, Allison M; Ogburn, Elizabeth; Moulton, Lawrence H; Srikrishnan, Aylur K; Kumar, M Suresh; Anand, Santhanam; Solomon, Suniti; Mehta, Shruti H

    2016-11-14

    Globally, men who have sex with men and people who inject drugs remain disproportionately affected by HIV, but they have not been the focus of prevention and treatment interventions in many resource-limited settings. This cluster-randomized trial (conducted from June 2012 to June 2017), evaluates whether single-venue, integrated delivery of core HIV services to vulnerable high-risk populations improves service utilization and consequently, HIV testing and other outcomes along the HIV care continuum. Core services include: HIV counseling and testing, information, education and communication, condom distribution, needle and syringe exchange programs, opioid agonist therapy, management of sexually transmitted infections, tuberculosis screening, diagnosis, and treatment, and antiretroviral therapy. Stratified restricted randomization was used to allocate 22 Indian cities (10 men who have sex with men and 12 people who inject drugs sites) at a 1:1 ratio to either the intervention or control condition. Integrated care centers were scaled-up and implemented in the 11 intervention cities and outcomes will be assessed by pre- and post-intervention surveys at intervention and control sites. As men who have sex with men and people who inject drugs are hidden populations, with no sampling frame, respondent-driven sampling will be used to accrue samples for the two independent cross-sectional surveys. For an AIDS-free generation to be realized, prevention, care and treatment services need to reach all populations at risk for HIV infection. There is a clear gap in access to services among men who have sex with men and people who inject drugs. Trials need to be designed to optimize utilization of services in these populations. ClinicalTrials.gov Identifier: NCT01686750 Date of Registration: September 13, 2012.

  18. Double insemination and gonadotropin-releasing hormone treatment of repeat-breeding dairy cattle.

    PubMed

    Stevenson, J S; Call, E P; Scoby, R K; Phatak, A P

    1990-07-01

    Our objective was to determine if double inseminations during the same estrous period of dairy cattle eligible for their third or fourth service (repeat breeders) would improve pregnancy rates equivalent to injections of GnRH given at the time of AI. Repeat-breeding, lactating cows from six herds (five herds in the San Joaquin Valley of central California and one herd in northeast Kansas) were assigned randomly to four treatment groups when detected in estrus: 1) single AI plus no injection, 2) single AI plus 100 micrograms GnRH at AI, 3) double AI plus no injection, or 4) double AI plus 100 micrograms of GnRH at AI. Inseminations were performed according to the a.m.-p.m. rule. The second AI for the double AI treatment was given 12 to 16 h after the first AI. Injections of GnRH were given intramuscularly immediately following the single AI or the first AI of the double AI. Pregnancy rates of cows given a single AI and hormone injection were numerically higher in all six herds than those of their herdmates given only a single AI. In five of six herds, the pregnancy rates of cows given a double AI and hormone injection were numerically higher than pregnancy rates of their herdmates given only a double AI. Overall pregnancy rates for the four treatments were 1) 112/353 (32.1%), 2) 165/406 (41.6%), 3) 119/364 (33.5%), and 4) 135/359 (37.5%). Gonadotropin-releasing hormone increased pregnancy rates of repeat breeders compared with controls given only a single AI. No further benefit beyond the single AI was accrued from the double AI treatment, with or without concurrent hormone administration.

  19. Probing the water distribution in porous model sands with two immiscible fluids: A nuclear magnetic resonance micro-imaging study

    NASA Astrophysics Data System (ADS)

    Lee, Bum Han; Lee, Sung Keun

    2017-10-01

    The effect of the structural heterogeneity of porous networks on the water distribution in porous media, initially saturated with immiscible fluid followed by increasing durations of water injection, remains one of the important problems in hydrology. The relationship among convergence rates (i.e., the rate of fluid saturation with varying injection time) and the macroscopic properties and structural parameters of porous media have been anticipated. Here, we used nuclear magnetic resonance (NMR) micro-imaging to obtain images (down to ∼50 μm resolution) of the distribution of water injected for varying durations into porous networks that were initially saturated with silicone oil. We then established the relationships among the convergence rates, structural parameters, and transport properties of porous networks. The volume fraction of the water phase increases as the water injection duration increases. The 3D images of the water distributions for silica gel samples are similar to those of the glass bead samples. The changes in water saturation (and the accompanying removal of silicone oil) and the variations in the volume fraction, specific surface area, and cube-counting fractal dimension of the water phase fit well with the single-exponential recovery function { f (t) = a [ 1 -exp (- λt) ] } . The asymptotic values (a, i.e., saturated value) of the properties of the volume fraction, specific surface area, and cube-counting fractal dimension of the glass bead samples were greater than those for the silica gel samples primarily because of the intrinsic differences in the porous networks and local distribution of the pore size and connectivity. The convergence rates of all of the properties are inversely proportional to the entropy length and permeability. Despite limitations of the current study, such as insufficient resolution and uncertainty for the estimated parameters due to sparsely selected short injection times, the observed trends highlight the first analyses of the cube-counting fractal dimension (and other structural properties) and convergence rates in porous networks consisting of two fluid components. These results indicate that the convergence rates correlate with the geometric factor that characterizes the porous networks and transport property of the porous networks.

  20. Safety Study: Intraventricular Injection of a Modified Oncolytic Measles Virus into Measles-Immune, hCD46-Transgenic, IFNαRko Mice.

    PubMed

    Lal, Sangeet; Peng, Kah-Whye; Steele, Michael B; Jenks, Nathan; Ma, Hong; Kohanbash, Gary; Phillips, Joanna J; Raffel, Corey

    2016-12-01

    The modified Edmonston vaccine strain of measles virus (MV) has shown potent oncolytic efficacy against various tumor types and is being investigated in clinical trials. Our laboratory showed that MV effectively kills medulloblastoma tumor cells in both localized disease and when tumor cells are disseminated through cerebrospinal fluid (CSF). Although the safety of repeated intracerebral injection of modified MV in rhesus macaques has been established, the safety of administering MV into CSF has not been adequately investigated. In this study, we assessed the safety of MV-NIS (MV modified to express the human sodium iodide symporter protein) injected into the CSF of measles-immunized and measles virus-susceptible transgenic (CD46, IFNαRko) mice. Treated animals were administered a single intraventricular injection of 1 × 10 5 or 1 × 10 6 TCID 50 (50% tissue culture infective dose) of MV-NIS. Detailed clinical observation was performed over a 90-day period. Clinically, we did not observe any measles-related toxic effects or behavioral abnormality in animals of any treated cohort. The complete blood count and blood chemistry analysis results were found to be within normal range for all the cohorts. Histologic examination of brains and spinal cords revealed inflammatory changes, mostly related to the needle track; these resolved by day 21 postinjection. To assess viral biodistribution, quantitative RT-PCR to detect the measles virus N-protein was performed on blood and brain samples. Viral RNA was not detectable in the blood as soon as 2 days after injection, and virus cleared from the brain by 45 days postadministration in all treatment cohorts. In conclusion, our data suggest that a single injection of modified MV into the CSF is safe and can be used in future therapeutic applications.

  1. Accuracy of palpation-directed intra-articular glenohumeral injection confirmed by magnetic resonance arthrography.

    PubMed

    Powell, Scott E; Davis, Shane M; Lee, Emily H; Lee, Robert K; Sung, Ryan M; McGroder, Claire; Kouk, Shalen; Lee, Christopher S

    2015-02-01

    The aim of this study was to determine the accuracy of anatomic palpation-directed injections in the office setting. Two hundred twenty-six shoulders in 208 patients were studied using a 0.2-Tesla extremity scanner after the injection of gadolinium-diethylene triamine pentaacetic acid-saline. All patients were injected in a sterile fashion by a single board-certified shoulder surgeon using an anterior approach by palpating the rotator interval anterior to the acromioclavicular joint and angling the needle 45° lateral and 45° caudad. All injections, successful or otherwise, were single injections. Magnetic resonance (MR) arthrograms were retrospectively read by 2 musculoskeletal fellowship-trained, board certified radiologists to determine whether the injection was in the glenohumeral joint. Two hundred one of the 226 injections were successful (88.9%). Of the 25 unsuccessful injections, the contrast material extravasated out of the capsule in 5 cases and into the subscapularis tendon in 10 cases. The contrast material was injected into the subacromial space in 9 cases, into the rotator interval fat in 9 cases, and into extracapsular tissue in 6 cases. There was insufficient volume of contrast material in 10 cases. The accuracy rate was 88.9%. There were no complications. The palpation-directed rotator interval anterior approach technique for intra-articular glenohumeral MR arthrogram injections performed by a single surgeon was 88.9% accurate. Level IV, therapeutic case series. Copyright © 2015 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  2. Endoscopic Cyanoacrylate Injection with Post-injection Audible Doppler Assessment of Gastric Varices: A Single-Institution Experience.

    PubMed

    Catron, Tom D; Smallfield, George B; Kang, Le; Sterling, Richard K; Siddiqui, Mohammad S

    2017-11-01

    Gastric varices (GV) have higher rates of morbidity and mortality from hemorrhage than esophageal varices. Several studies have shown the safety and efficacy of cyanoacrylate (CA) injection for acute gastric variceal hemorrhage. We report data from our experience with CA injection for GV before and after routine use of post-injection audible Doppler assessment (ADA) for GV obturation and describe long-term outcomes after this therapy. We retrospectively identified patients who had documented GV, underwent CA injection, and had at least 2 weeks of follow-up. We recorded and analyzed the survival and rebleeding rates with patient demographics, clinical data, and endoscopy findings between two groups of patients who were categorized by CA injection prior to and after inception of the ADA technique. Seventy-one patients were identified with 16 patients analyzed in a group where ADA was not used (Pre-ADA) and 55 analyzed where ADA was used (Post-ADA). No rebleeding events were observed within 1 week of initial CA injection. No embolic events were reported after any initial CA injection within 4 weeks. The rate of bleed-free survival at 1 year was 69.6% in the Pre-ADA group and 85.8% in the Post-ADA without statistical significance. The all-cause 1-year mortality was 13.8% in the Pre-ADA group and 10.7% in the Post-ADA group without statistical significance. ADA of CA-injected GV does not appear to significantly affect adverse events or clinical outcomes; however, our findings are limited by small sample size and cohort proportions allowing for significant type II statistical error. Further prospective investigation is required to determine the impact of ADA on clinical outcomes after GV obturation.

  3. Effect of Vortex Circulation on Injectant from a Single Film-Cooling Hole and a Row of Film-Cooling Holes in a Turbulent Boundary Layer. Part 1. Injection Beneath the Vortex Downwash

    DTIC Science & Technology

    1989-06-01

    coefficients vortex circulation, symbols used in vorticity plots representing circulation values derived from different vortex core models injection...derived from different vortex core models dimensionless core size parameter: t wice the a verage core radius divided by t h e i n jection hole...Wall Heating, xjd=109.2, m=0.5, Single Injection Hole Vortex w, Temp. Difference Range (.5- 2.5) degree s 91. Local Temperature Distribution

  4. Integrated injection-locked semiconductor diode laser

    DOEpatents

    Hadley, G. Ronald; Hohimer, John P.; Owyoung, Adelbert

    1991-01-01

    A continuous wave integrated injection-locked high-power diode laser array is provided with an on-chip independently-controlled master laser. The integrated injection locked high-power diode laser array is capable of continuous wave lasing in a single near-diffraction limited output beam at single-facet power levels up to 125 mW (250 mW total). Electronic steering of the array emission over an angle of 0.5 degrees is obtained by varying current to the master laser. The master laser injects a laser beam into the slave array by reflection of a rear facet.

  5. Single peak parameters technique for simultaneous measurements: Spectrophotometric sequential injection determination of Fe(II) and Fe(III).

    PubMed

    Kozak, J; Paluch, J; Węgrzecka, A; Kozak, M; Wieczorek, M; Kochana, J; Kościelniak, P

    2016-02-01

    Spectrophotometric sequential injection system (SI) is proposed to automate the method of simultaneous determination of Fe(II) and Fe(III) on the basis of parameters of a single peak. In the developed SI system, sample and mixture of reagents (1,10-phenanthroline and sulfosalicylic acid) are introduced into a vessel, where in an acid environment (pH≅3) appropriate compounds of Fe(II) and Fe(III) with 1,10-phenanthroline and sulfosalicylic acid are formed, respectively. Then, in turn, air, sample, EDTA and sample again, are introduced into a holding coil. After the flow reversal, a segment of air is removed from the system by an additional valve and as EDTA replaces sulfosalicylic acid forming a more stable colorless compound with Fe(III), a complex signal is registered. Measurements are performed at wavelength 530 nm. The absorbance measured at minimum of the negative peak and the area or the absorbance measured at maximum of the signal can be used as measures corresponding to Fe(II) and Fe(III) concentrations, respectively. The time of the peak registration is about 2 min. Two-component calibration has been applied to analysis. Fe(II) and Fe(III) can be determined within the concentration ranges of 0.04-4.00 and 0.1-5.00 mg L(-1), with precision less than 2.8% and 1.7% (RSD), respectively and accuracy better than 7% (RE). The detection limit is 0.04 and 0.09 mg L(-1) for Fe(II) and Fe(III), respectively. The method was applied to analysis of artesian water samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Nanovaccine for leishmaniasis: preparation of chitosan nanoparticles containing Leishmania superoxide dismutase and evaluation of its immunogenicity in BALB/c mice

    PubMed Central

    Danesh-Bahreini, Mohammad Ali; Shokri, Javad; Samiei, Afshin; Kamali-Sarvestani, Eskandar; Barzegar-Jalali, Mohammad; Mohammadi-Samani, Soliman

    2011-01-01

    Background: Leishmaniasis is a protozoan disease, affecting 12 million people in different regions of the world with a wide spectrum of diseases. Although several chemotherapeutic agents have been used for treating the disease, long-term therapy, limited efficacy and the development of drug-resistant parasites remain the major limitations. Methods: To develop a new nanovaccine for leishmaniasis, recombinant Leishmania superoxide dismutase (SODB1) was loaded onto chitosan nanoparticles by the ionotropic gelation method. Size and loading efficiency of the nanoparticles were evaluated and optimized, and an immunization study was undertaken on BALB/c mice. The mice received phosphate buffer saline (PBS), superoxide dismutase B1 (SODB1) in PBS and nanoparticles via subcutaneous injection. Soluble Leishmania Antigens (SLA) and complete Freund’s adjuvant (CFA) were also injected subcutaneously three times every three weeks (some groups received only a single dose). Three weeks after the last injection, blood samples were collected and assessed with ELISA to detect IgG2a and IgG1. Results: Immunological analysis showed that in single and triple doses of SODB1 nanoparticles, IgG2a and IgG2a/IgG1 were significantly higher than the other groups (P<0.05). Conclusion: The results revealed that formulations of SODB1 in biodegradable and stable chitosan nanoparticles can increase the immunogenicity toward cell-mediated immunity (TH1 cells producing IgG2a in mice) that is effective in Leishmania eradication and could be presented as a single dose nanovaccine for leishmaniasis. PMID:21589651

  7. Pushing quantitation limits in micro UHPLC-MS/MS analysis of steroid hormones by sample dilution using high volume injection.

    PubMed

    Márta, Zoltán; Bobály, Balázs; Fekete, Jenő; Magda, Balázs; Imre, Tímea; Mészáros, Katalin Viola; Szabó, Pál Tamás

    2016-09-10

    Ultratrace analysis of sample components requires excellent analytical performance in terms of limits of quantitation (LoQ). Micro UHPLC coupling with sensitive tandem mass spectrometry provides state of the art solutions for such analytical problems. Decreased column volume in micro LC limits the injectable sample volume. However, if analyte concentration is extremely low, it might be necessary to inject high sample volumes. This is particularly critical for strong sample solvents and weakly retained analytes, which are often the case when preparing biological samples (protein precipitation, sample extraction, etc.). In that case, high injection volumes may cause band broadening, peak distortion or even elution in dead volume. In this study, we evaluated possibilities of high volume injection onto microbore RP-LC columns, when sample solvent is diluted. The presented micro RP-LC-MS/MS method was optimized for the analysis of steroid hormones from human plasma after protein precipitation with organic solvents. A proper sample dilution procedure helps to increase the injection volume without compromising peak shapes. Finally, due to increased injection volume, the limit of quantitation can be decreased by a factor of 2-5, depending on the analytes and the experimental conditions. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Pharmacokinetics of dinalbuphine sebacate and nalbuphine in human after intramuscular injection of dinalbuphine sebacate in an extended-release formulation.

    PubMed

    Tien, Yu En; Huang, Wen-Chuan; Kuo, Hui-Yuan; Tai, Lily; Uang, Yow-Shieng; Chern, Wendy H; Huang, Jin-Ding

    2017-11-01

    Nalbuphine is a semi-synthetic opioid indicated for the relief of moderate to severe pain. Its short half-life requires frequent injections in clinical practice, resulting in a greater incidence of adverse events. A prodrug of nalbuphine has been developed, dinalbuphine sebacate (DNS), dissolved in a simple oil-based injectable formulation, which could deliver and maintain an effective blood level of nalbuphine. An open-label, prospective, two-period study was performed in healthy volunteers to verify the extended blood concentration profile of nalbuphine. Twelve healthy Taiwanese were randomized to receive an intramuscular injection of 20 mg nalbuphine HCl and 150 mg DNS sequentially with a washout period of 5 days. To prevent DNS hydrolysis during sample analysis, the effect of four esterase inhibitors was evaluated in the quantitation of DNS in human whole blood and thenoyltrifluoroacetone was chosen. The bioavailability of nalbuphine from intramuscularly injected DNS relative to that from nalbuphine HCl was 85.4%. The mean absorption time of nalbuphine from DNS was 145.2 h. It took approximately 6 days for the complete release of DNS into the blood stream where DNS was rapidly hydrolysed to nalbuphine; suggesting a single injection of 150 mg DNS in our extended-release formulation could provide long-lasting pain relief. Copyright © 2017 John Wiley & Sons, Ltd.

  9. Optimal timing and frequency of bone marrow soup therapy for functional restoration of salivary glands injured by single-dose or fractionated irradiation.

    PubMed

    Fang, Dongdong; Shang, Sixia; Liu, Younan; Bakkar, Mohammed; Sumita, Yoshinori; Seuntjens, Jan; Tran, Simon D

    2018-02-01

    Injections of bone marrow (BM) cell extract, known as 'BM soup', were previously reported to mitigate ionizing radiation (IR) injury to salivary glands (SGs). However, the optimal starting time and frequency to maintain BM soup therapeutic efficacy remains unknown. This study tested the optimal starting time and frequency of BM soup injections in mice radiated with either a single dose or a fractionated dose. First, BM soup treatment was started at 1, 3 or 7 weeks post-IR; positive (non-IR) and negative (IR) control mice received injections of saline (vehicle control). Second, BM soup-treated mice received injections at different frequencies (1, 2, 3 and 5 weekly injections). Third, a 'fractionated-dose radiation' model to injure mouse SGs was developed (5 Gy × 5 days) and compared with the single high dose radiation model. All mice (n = 65) were followed for 16 weeks post-IR. The results showed that starting injections of BM soup between 1 and 3 weeks mitigated the effect of IR-induced injury to SGs and improved the restoration of salivary function. Although the therapeutic effect of BM soup lessens after 8 weeks, it can be sustained by increasing the frequency of weekly injections. Moreover, both single-dose and fractionated-dose radiation models are efficient and comparable in inducing SG injury and BM soup treatments are effective in restoring salivary function in both radiation models. In conclusion, starting injections of BM soup within 3 weeks post-radiation, with 5 weekly injections, maintains 90-100% of saliva flow in radiated mice. Copyright © 2017 John Wiley & Sons, Ltd.

  10. Comparing respondent-driven sampling and targeted sampling methods of recruiting injection drug users in San Francisco.

    PubMed

    Kral, Alex H; Malekinejad, Mohsen; Vaudrey, Jason; Martinez, Alexis N; Lorvick, Jennifer; McFarland, Willi; Raymond, H Fisher

    2010-09-01

    The objective of this article is to compare demographic characteristics, risk behaviors, and service utilization among injection drug users (IDUs) recruited from two separate studies in San Francisco in 2005, one which used targeted sampling (TS) and the other which used respondent-driven sampling (RDS). IDUs were recruited using TS (n = 651) and RDS (n = 534) and participated in quantitative interviews that included demographic characteristics, risk behaviors, and service utilization. Prevalence estimates and 95% confidence intervals (CIs) were calculated to assess whether there were differences in these variables by sampling method. There was overlap in 95% CIs for all demographic variables except African American race (TS: 45%, 53%; RDS: 29%, 44%). Maps showed that the proportion of IDUs distributed across zip codes were similar for the TS and RDS sample, with the exception of a single zip code that was more represented in the TS sample. This zip code includes an isolated, predominantly African American neighborhood where only the TS study had a field site. Risk behavior estimates were similar for both TS and RDS samples, although self-reported hepatitis C infection was lower in the RDS sample. In terms of service utilization, more IDUs in the RDS sample reported no recent use of drug treatment and syringe exchange program services. Our study suggests that perhaps a hybrid sampling plan is best suited for recruiting IDUs in San Francisco, whereby the more intensive ethnographic and secondary analysis components of TS would aid in the planning of seed placement and field locations for RDS.

  11. Sequential injection system for simultaneous determination of sucrose and phosphate in cola drinks using paired emitter-detector diode sensor.

    PubMed

    Saetear, Phoonthawee; Khamtau, Kittiwut; Ratanawimarnwong, Nuanlaor; Sereenonchai, Kamonthip; Nacapricha, Duangjai

    2013-10-15

    This work presents the simultaneous determination of sucrose and phosphate by using sequential injection (SI) system with a low cost paired emitter-detector diode (PEDD) light sensor. The PEDD uses two 890 nm LEDs. Measurement of sucrose in Brix unit was carried out based on the detection of light refraction occurring at the liquid interface (the schlieren effect) between the sucrose solution and water. Phosphate was measured from the formation of calcium phosphate with turbidimetric detection. With careful design of the loading sequence and volume (sample--precipitating reagent--sample), simultaneous detection of sucrose and phosphate was accomplished with the single PEDD detector. At the optimized condition, linear calibrations from 1 to 7 Brix sucrose and from 50 to 200mg PO4(3-)L(-1) were obtained. Good precision at lower than 2% RSD (n=10) for both analytes with satisfactory throughput of 21 injections h(-1) was achieved. The method was successfully applied for the determination of sucrose and phosphate in cola drinks. The proposed method is readily applicable for automation and is found to be an alternative method to conventional procedures for on-line quality control process in cola drink industry. Crown Copyright © 2013. Published by Elsevier B.V. All rights reserved.

  12. The AAHKS Clinical Research Award: Liposomal Bupivacaine and Periarticular Injection Are Not Superior to Single-Shot Intra-articular Injection for Pain Control in Total Knee Arthroplasty.

    PubMed

    Jain, Rajesh K; Porat, Manny D; Klingenstein, Greg G; Reid, Jeremy J; Post, Robert E; Schoifet, Scott D

    2016-09-01

    Intraoperative injections can help reduce early postoperative pain in total knee arthroplasty. We proposed that liposomal bupivacaine would not be superior to more common and cheaper injections. A single-blinded prospective randomized study with 207 consecutive patients was completed. Patients were randomized to treatment with periarticular liposomal bupivacaine injection, periarticular injection of bupivacaine/morphine, or intra-articular injection of bupivacaine/morphine at the conclusion of the procedure. Postoperative visual analog pain scores and narcotic consumption were recorded and analyzed. There was no significant difference in postoperative visual analog pain scores or narcotic consumption among the 3 study groups. Intra-articular injection of bupivacaine and morphine is as effective for postoperative pain control in total knee arthroplasty as periarticular bupivacaine/morphine injection and liposomal bupivacaine. Use of liposomal bupivacaine in total knee arthroplasty is costly and not justified. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Single-center, single-dose, open-label, randomized, two-period crossover study on the bioavailability of methotrexate administered using a novel prefilled, needle-free delivery system.

    PubMed

    Bienvenu, Boris; Aouba, Achille; Gottenberg, Jacques-Eric; Verstuyft, Celine

    2017-04-01

    Zeneo 1 is a needle-free injection device. We performed a pharmacokinetic study to investigate the bioequivalence of methotrexate administered subcutaneously using either the needle-free injection device or a conventional needle and syringe. This was a single-dose, open-label, laboratory-blind, randomized crossover study performed in adult healthy volunteers. Each participant received two methotrexate injections (each 25 mg), one via needle-free injection device and one via conventional injection, with a 21-28 day wash-out interval between dosing. For each participant, the administration site for both injections was either the abdomen or the thigh. The primary pharmacokinetic outcome parameters were AUC (0- t ) and C max . Bioequivalence was assessed by standard criteria: whether 90% confidence intervals of geometric mean ratios for the two administration methods were within 80-125%. Fifty-two individuals completed the study. Bioequivalence criteria were met for AUC (0- t ) , for the overall analysis (both injection sites: 90% confidence interval: 99.4-103.1%), and for each injection site separately. Bioequivalence was similarly demonstrated with AUC (0-∞) . Bioequivalence criteria for C max were fulfilled for abdominal administration but not for the overall analysis. Injection via the needle-free injection device was well tolerated. Limitations include conducting the study in healthy volunteers and the relatively small subject number (albeit satisfactory for bioequivalence). This study shows that methotrexate injection via needle-free injection device is bioequivalent to a conventional needle and syringe in relation to AUC (0- t ) and AUC (0-∞) . Studies of needle-free injection device use in patients requiring methotrexate therapy are planned.

  14. Single Shot Epidural Injection for Cervical and Lumbosaccral Radiculopathies: A Preliminary Study

    PubMed Central

    Nawani, Digambar Prasad; Asthana, Veena

    2010-01-01

    Background Epidural steroid injection is an established treatment modality for intervertebral disc prolapse leading to radiculopathy. In cases where two levels of radiculopathy are present, two separate injections are warranted. Herein, we present our experience of management of such cases with a single epidural injection of local anaesthetic, tramadol and methylprednisolone, and table tilt for management of both radiculopathies. Methods 50 patients of either sex aged between 35-65 years presenting with features of cervical and lumbar radiculopathic pain were included and were subjected to single lumbar epidural injection of local anaesthetic, tramadol and methylprednisolone, in the lateral position. The table was then tilted in the trendelberg position with a tilt of 25 degrees, and patients were maintained for 10 minutes before being turned supine. All patients were administered 3 such injections with an interval of 2 weeks between subsequent injections, and pain relief was assessed with a visual analogue scale. Immediate complications after the block were assessed. Results Immediate and post procedural complications observed were nausea and vomiting (20%), painful injection site (4%), hypotension (10%) and high block (4%). Pain relief was assessed after the three injections by three grades: 37 (74%) had complete resolution of symptoms; 18% had partial relief and 8% did not benefit from the procedure. Conclusions This technique may be used as an alternative technique for pain relief in patients with unilateral cervical and lumbar radiculopathies. PMID:21217889

  15. Hydrodynamic injection with pneumatic valving for microchip electrophoresis with total analyte utilization

    PubMed Central

    Sun, Xuefei; Kelly, Ryan T.; Danielson, William F.; Agrawal, Nitin; Tang, Keqi; Smith, Richard D.

    2011-01-01

    A novel hydrodynamic injector that is directly controlled by a pneumatic valve has been developed for reproducible microchip capillary electrophoresis (CE) separations. The poly(dimethylsiloxane) (PDMS) devices used for evaluation comprise a separation channel, a side channel for sample introduction, and a pneumatic valve aligned at the intersection of the channels. A low pressure (≤ 3 psi) applied to the sample reservoir is sufficient to drive sample into the separation channel. The rapidly actuated pneumatic valve enables injection of discrete sample plugs as small as ~100 pL for CE separation. The injection volume can be easily controlled by adjusting the intersection geometry, the solution back pressure and the valve actuation time. Sample injection could be reliably operated at different frequencies (< 0.1 Hz to >2 Hz) with good reproducibility (peak height relative standard deviation ≤ 3.6%) and no sampling biases associated with the conventional electrokinetic injections. The separation channel was dynamically coated with a cationic polymer, and FITC-labeled amino acids were employed to evaluate the CE separation. Highly efficient (≥ 7.0 × 103 theoretical plates for the ~2.4 cm long channel) and reproducible CE separations were obtained. The demonstrated method has numerous advantages compared with the conventional techniques, including repeatable and unbiased injections, little sample waste, high duty cycle, controllable injected sample volume, and fewer electrodes with no need for voltage switching. The prospects of implementing this injection method for coupling multidimensional separations, for multiplexing CE separations and for sample-limited bioanalyses are discussed. PMID:21520147

  16. Pharmacokinetics and tolerability of intravenous ibuprofen injection in healthy Chinese volunteers: a randomized, open-label, single- and multiple-dose study
.

    PubMed

    Zhou, Huili; Xu, Wei; Wu, Guolan; Wu, Lihua; Shentu, Jianzhong; Pan, Zhengfei; Hu, Shuai; Liu, Yang

    2016-11-01

    Recently a formulation of intravenous (IV) ibuprofen was developed in China for management of mild to moderate pain in patients who could not take oral medications or where intravenous administration was preferable. The aim of this study was to evaluate the pharmacokinetic properties and tolerability of single and multiple doses of ibuprofen injection in healthy Chinese volunteers. This open-label, single- and multiple-dose study was conducted in healthy Chinese volunteers. In the single-dose phase, subjects were randomized to receive a single dose of ibuprofen injection 0.2, 0.4, or 0.8 g administered as a 30-minute IV infusion with a 1-week washout between periods. Blood samples were collected at regular intervals from 0 to 12.5 hours after drug administration and were analyzed using a validated LC-MS/MS method. In the multiple-dose phase, subjects received 0.4 g ibuprofen every 6 hours for 9 doses. Blood samples were obtained before the 7th, 8th, and 9th administration to determine the Cmin at steady state; on the 9th intravenous administration, blood samples were also collected for 12.5 hours after drug administration. Pharmacokinetic parameters were estimated using a noncompartmental model. Tolerability was determined using clinical evaluation and monitoring of adverse events (AEs). A total of 12 healthy male (n = 6) and female (n = 6) Chinese volunteers were enrolled and completed the trial. After IV administration of single dose, the mean (SD) Cmax value increased from 35.77 (6.98) to 117.12 (19.78) µg/mL, and the mean (SD) AUC0-t value increased from 67.63 (10.30) to 230.50 (33.55) µg×h/mL in the range of 0.2-g to 0.8-g dose. The terminal half-life in plasma was ~ 2.0 hours. After IV administration of 9 doses of ibuprofen 400 mg every 6 hours, the mean (SD) Cmax was 66.49 (8.49) µg/mL, the AUC0-t was 135.65 (26.91) µg×h/mL, the t1/2 was 2.14 (0.34) hours, the Cl/F was 3.34 (0.68) L/h, and the Vz/F was 10.32 (2.69) L, which were comparable with those after single dosing. The accumulation index was 1.17 (0.06), and the fluctuation was 304.0 (57.7) %. Results of the t-tests of Cmax and AUC found no significant differences between the male and female groups. No serious AEs were reported, and there were no discontinuations due to AEs. The pharmacokinetics of ibuprofen exhibited dose-related kinetics from the 0.2- to the 0.8-g dose. After multiple doses, the pharmacokinetic parameters of ibuprofen were consistent with those after single doses. There was no accumulation in ibuprofen exposure in healthy Chinese between multiple doses and single dose. At the doses studied, ibuprofen appeared to be well tolerated in these healthy volunteers.
.

  17. HIV and hepatitis C virus infections among hanka injection drug users in central Ukraine: a cross-sectional survey.

    PubMed

    Dumchev, Kostyantyn V; Soldyshev, Ruslan; Qian, Han-Zhu; Zezyulin, Olexandr O; Chandler, Susan D; Slobodyanyuk, Pavel; Moroz, Larisa; Schumacher, Joseph E

    2009-08-23

    Ukraine has experienced an increase in injection drug use since the 1990s. An increase in HIV and hepatitis C virus infections has followed, but not measures of prevalence and risk factors. The purposes of this study are to estimate the prevalence of HIV, HCV, and co-infection among injection drug users (IDUs) in central Ukraine and to describe risk factors for HIV and HCV. A sample of 315 IDUs was recruited using snowball sampling for a structured risk interview and HIV/HCV testing (81.9% male, 42% single, average age 28.9 years [range = 18 to 55]). HIV and HCV antibodies were detected in 14.0% and 73.0%, respectively, and 12.1% were seropositive for both infections. The most commonly used drug was hanka, home-made from poppy straw and often mixed with other substances including dimedrol, diazepines, and hypnotics. The average period of injecting was 8.5 years; 62.5% reported past-year sharing needles or injection equipment, and 8.0% shared with a known HIV-positive person. More than half (51.1%) reported multiple sexual partners, 12.9% buying or selling sex, and 10.5% exchanging sex and drugs in the past year. Those who shared with HIV positive partners were 3.4 times more likely to be HIV positive than those who did not. Those who front- or back-loaded were 4 times more likely to be HCV positive than those who did not. Harm reduction, addiction treatment and HIV prevention programs should address risk factors to stop further spread of both HIV and HCV among IDUs and to the general population in central Ukraine.

  18. Outcome and predicting factors of single and multiple intra-articular corticosteroid injections in children with juvenile idiopathic arthritis.

    PubMed

    Lanni, Stefano; Bertamino, Marta; Consolaro, Alessandro; Pistorio, Angela; Magni-Manzoni, Silvia; Galasso, Roberta; Lattanzi, Bianca; Calvo-Aranda, Enrique; Martini, Alberto; Ravelli, Angelo

    2011-09-01

    To investigate the efficacy of IA CS (IAC) therapy in single and multiple joints in children with JIA and to seek for predictors of synovitis flare. The clinical charts of patients who received their first IAC injection between January 2002 and December 2008 were reviewed. The CS used was triamcinolone hexacetonide for large joints and methylprednisolone acetate for small or difficult to access joints. Patients were stratified as follows: one joint injected; two joints injected; and three or more joints injected. Predictors included sex, age at disease onset, JIA category, age and disease duration, ANA status, iridocyclitis, general anaesthesia, number and type of injected joints, acute-phase reactants and concomitant MTX therapy. The cumulative probability of survival without synovitis flare for patients injected in one, two, or three or more joints was 70, 45 and 44%, respectively, at 1 year; 61, 32 and 30%, respectively, at 2 years; and 37, 22 and 19%, respectively, at 3 years. On Cox regression analysis, positive CRP, negative ANA and injection in the ankle were the strongest predictors for synovitis flare. The only significant side effect was skin hypopigmentation or s.c. atrophy, which occurred in <2% of patients. IAC therapy-induced sustained remission of synovitis in a substantial proportion of patients injected either in single or multiple joints, with a good safety profile. The risk of synovitis flare was higher in patients who had positive CRP, negative ANA and were injected in the ankle.

  19. Differential Profiling of Volatile Organic Compound Biomarker Signatures Utilizing a Logical Statistical Filter-Set and Novel Hybrid Evolutionary Classifiers

    DTIC Science & Technology

    2012-04-01

    for automated SPME headspace sampling and in-line with a Thermo DSQII single quadrupole mass spectrometer. Collection of organic volatiles from the...urine was accomplished using a 2cm CAR/DVB/PDMS solid phase micro extraction fiber ( SPME ), Supelco supplier, inserted by the Triplus autosampler into...automated direct injection. Volatiles gathered by the SPME fiber were analyzed through desorption of the fiber by heating to elevated temperature and

  20. DE-SC0004118 (Wong & Lindquist). Final Report: Changes of Porosity, Permeability and Mechanical Strength Induced by Carbon Dioxide Sequestration.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    WONG, TENG-FONG; Lindquist, Brent

    In the context of CO{sub 2} sequestration, the overall objective of this project is to conduct a systematic investigation of how the flow of the acidic, CO{sub 2} saturated, single phase component of the injected/sequestered fluid changes the microstructure, permeability and strength of sedimentary rocks, specifically limestone and sandstone samples. Hydromechanical experiments, microstructural observations and theoretical modeling on multiple scales were conducted.

  1. Nursing benefits of using an automated injection system for ictal brain single photon emission computed tomography.

    PubMed

    Vonhofen, Geraldine; Evangelista, Tonya; Lordeon, Patricia

    2012-04-01

    The traditional method of administering radioactive isotopes to pediatric patients undergoing ictal brain single photon emission computed tomography testing has been by manual injections. This method presents certain challenges for nursing, including time requirements and safety risks. This quality improvement project discusses the implementation of an automated injection system for isotope administration and its impact on staffing, safety, and nursing satisfaction. It was conducted in an epilepsy monitoring unit at a large urban pediatric facility. Results of this project showed a decrease in the number of nurses exposed to radiation and improved nursing satisfaction with the use of the automated injection system. In addition, there was a decrease in the number of nursing hours required during ictal brain single photon emission computed tomography testing.

  2. A Ka-band chirped-pulse Fourier transform microwave spectrometer

    NASA Astrophysics Data System (ADS)

    Zaleski, Daniel P.; Neill, Justin L.; Muckle, Matt T.; Seifert, Nathan A.; Brandon Carroll, P.; Widicus Weaver, Susanna L.; Pate, Brooks H.

    2012-10-01

    The design and performance of a new chirped-pulse Fourier transform microwave (CP-FTMW) spectrometer operating from 25 to 40 GHz (Ka-band) is presented. This spectrometer is well-suited for the study of complex organic molecules of astronomical interest in the size range of 6-10 atoms that have strong rotational transitions in Ka-band under pulsed jet sample conditions (Trot = 1-10 K). The spectrometer permits acquisition of the full spectral band in a single data acquisition event. Sensitivity is enhanced by using two pulsed jet sources and acquiring 10 broadband measurements for each sample injection cycle. The spectrometer performance is benchmarked by measuring the pure rotational spectrum of several isotopologues of acetaldehyde in natural abundance. The rotational spectra of the singly substituted 13C and 18O isotopologues of the two lowest energy conformers of ethyl formate have been analyzed and the resulting substitution structures for these conformers are compared to electronic structure theory calculations.

  3. Pellet injection research on the HT-6M and HT-7 tokamaks

    NASA Astrophysics Data System (ADS)

    Yang, Yu; Bao, Yi; Li, Jiangang; Gu, Xuemao; He, Yexi

    1999-11-01

    A multishot in situ pellet injection system has been constructed in the Institute of Plasma Physics. Single- and multi-pellet injection experiments were performed on the HT-6M and superconducting HT-7 tokamaks. The system proved to be convenient and reliable to operate. Pellets were fired into ohmically and LHCD and ICRF heated plasmas. Single pellet injection in ohmic discharge was found to increase the central density of HT-7 by about one half, while two pellet injection increased the central density in a step-like fashion by one half with each shot. Peaking of the electron density profile and a hollow electron temperature profile were obtained.

  4. Slit injection device

    DOEpatents

    Alger, Terry W.; Schlitt, Leland G.; Bradley, Laird P.

    1976-06-15

    A laser cavity electron beam injection device provided with a single elongated slit window for passing a suitably shaped electron beam and means for varying the current density of the injected electron beam.

  5. Rapid Quantitative Analysis of Multiple Explosive Compound Classes on a Single Instrument via Flow-Injection Analysis Tandem Mass Spectrometry.

    PubMed

    Ostrinskaya, Alla; Kunz, Roderick R; Clark, Michelle; Kingsborough, Richard P; Ong, Ta-Hsuan; Deneault, Sandra

    2018-05-24

    A flow-injection analysis tandem mass spectrometry (FIA MSMS) method was developed for rapid quantitative analysis of 10 different inorganic and organic explosives. Performance is optimized by tailoring the ionization method (APCI/ESI), de-clustering potentials, and collision energies for each specific analyte. In doing so, a single instrument can be used to detect urea nitrate, potassium chlorate, 2,4,6-trinitrotoluene, 2,4,6-trinitrophenylmethylnitramine, triacetone triperoxide, hexamethylene triperoxide diamine, pentaerythritol tetranitrate, 1,3,5-trinitroperhydro-1,3,5-triazine, nitroglycerin, and octohy-dro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine with sensitivities all in the picogram per milliliter range. In conclusion, FIA APCI/ESI MSMS is a fast (<1 min/sample), sensitive (~pg/mL LOQ), and precise (intraday RSD < 10%) method for trace explosive detection that can play an important role in criminal and attributional forensics, counterterrorism, and environmental protection areas, and has the potential to augment or replace several of the existing explosive detection methods. © 2018 American Academy of Forensic Sciences.

  6. CO2 plume management in saline reservoir sequestration

    USGS Publications Warehouse

    Frailey, S.M.; Finley, R.J.

    2011-01-01

    A significant difference between injecting CO2 into saline aquifers for sequestration and injecting fluids into oil reservoirs or natural gas into aquifer storage reservoirs is the availability and use of other production and injection wells surrounding the primary injection well(s). Of major concern for CO2 sequestration using a single well is the distribution of pressure and CO2 saturation within the injection zone. Pressure is of concern with regards to caprock integrity and potential migration of brine or CO2 outside of the injection zone, while CO2 saturation is of interest for storage rights and displacement efficiency. For oil reservoirs, the presence of additional wells is intended to maximize oil recovery by injecting CO2 into the same hydraulic flow units from which the producing wells are withdrawing fluids. Completing injectors and producers in the same flow unit increases CO2 throughput, maximizes oil displacement efficiency, and controls pressure buildup. Additional injectors may surround the CO2 injection well and oil production wells in order to provide external pressure to these wells to prevent the injected CO2 from migrating from the pattern between two of the producing wells. Natural gas storage practices are similar in that to reduce the amount of "cushion" gas and increase the amount of cycled or working gas, edge wells may be used for withdrawal of gas and center wells used for gas injection. This reduces loss of gas to the formation via residual trapping far from the injection well. Moreover, this maximizes the natural gas storage efficiency between the injection and production wells and reduces the areal extent of the natural gas plume. Proposed U.S. EPA regulations include monitoring pressure and suggest the "plume" may be defined by pressure in addition to the CO2 saturated area. For pressure monitoring, it seems that this can only be accomplished by injection zone monitoring wells. For pressure, these wells would not need to be very close to the injection well, compared to monitoring wells intended to measure CO2 saturation via fluid sampling or cased-hole well logs. If pressure monitoring wells become mandated, these wells could be used for managing the CO2 saturation and aquifer pressure distribution. To understand the relevance and effectiveness of producing and injecting brine to improve storage efficiency, direct the plume to specific pore space, and redistribute the pressure, numerical models of CO2 injection into aquifers are used. Simulated cases include various aquifer properties at a single well site and varying the number and location of surrounding wells for plume management. Strategies in terms of completion intervals can be developed to effectively contact more vertical pore space in relatively thicker geologic formations. Inter-site plume management (or cooperative) wells for the purpose of pressure monitoring and plume management may become the responsibility of a consortium of operators or a government entity, not individual sequestration site operators. ?? 2011 Published by Elsevier Ltd.

  7. A Single Intravitreal Injection of Ranibizumab Provides No Neuroprotection in a Nonhuman Primate Model of Moderate-to-Severe Nonarteritic Anterior Ischemic Optic Neuropathy.

    PubMed

    Miller, Neil R; Johnson, Mary A; Nolan, Theresa; Guo, Yan; Bernstein, Steven L

    2015-12-01

    Ranibizumab, a vascular endothelial growth factor-antagonist, is said to be neuroprotective when injected intravitreally in patients with nonarteritic anterior ischemic optic neuropathy (NAION). We evaluated the efficacy of a single intravitreal (IVT) injection of ranibizumab in a nonhuman primate model of NAION (pNAION). We induced pNAION in one eye of four adult male rhesus monkeys using a laser-activated rose Bengal induction method. We then immediately injected the eye with either ranibizumab or normal saline (NS) intravitreally. We performed a clinical assessment, optical coherence tomography, electrophysiological testing, fundus photography, and fluorescein angiography in three of the animals (one animal developed significant retinal hemorrhages and, therefore, could not be analyzed completely) prior to induction, 1 day and 1, 2, and 4 weeks thereafter. Following the 4-week analysis of the first eye, we induced pNAION in the contralateral eye and then injected either ranibizumab or NS, whichever substance had not been injected in the first eye. We euthanized all animals 5 to 12 weeks after the final assessment of the second eye and performed both immunohistochemical and light and electron microscopic analyses of the retina and optic nerves of both eyes. A single IVT dose of ranibizumab administered immediately after induction of pNAION resulted in no significant reduction of clinical, electrophysiological, or histologic damage compared with vehicle-injected eyes. A single IVT dose of ranibizumab is not neuroprotective when administered immediately after induction of pNAION.

  8. Horizontal Magnetic Tweezers for Micromanipulation of Single DNA-Protein Complexes

    NASA Astrophysics Data System (ADS)

    McAndrew, C.; Sarkar, A.; Mehl, P.

    2011-03-01

    We report on the development of a new magnetic force transducer or ``tweezer'' that can apply pico-Newton forces on single DNA molecules in the focus plane. Since the changes in DNA's end-to-end extension are coplanar with the pulling force, there is no need to continually refocus. The DNA constructs (λ -DNA end labeled with a 3 μ m polystyrene bead and a 2.8 μ m paramagnetic sphere) and appropriate buffer are introduced to a custom built 400 μ L to 650 μ L closed cell. This closed cell isolates our sample and produces low-noise force and extension measurements. This chamber rests on a stage fixed to a three axis micromanipulator. Entering the flat chamber are two micropipettes, a 2.5 μ m id pipette for aspirating the polystyrene bead and a 20 μ m id pipette for injecting proteins of interest. The suction and the injection pipettes are rigidly mounted to a hydraulic, three-axis micromanipulator. DNA-bead constructs, once introduced to the chamber, can be located by moving the stage over the objective. We have shown that we can easily and reputably find, capture, and manipulate single molecules of DNA within a force range of 0.1pN to 100pN.

  9. A multi-staining chip using hydrophobic valves for exfoliative cytology in cancer

    NASA Astrophysics Data System (ADS)

    Lee, Tae Hee; Bu, Jiyoon; Moon, Jung Eun; Kim, Young Jun; Kang, Yoon-Tae; Cho, Young-Ho; Kim, In Sik

    2017-07-01

    Exfoliative cytology is a highly established technique for the diagnosis of tumors. Various microfluidic devices have been developed to minimize the sample numbers by conjugating multiple antibodies in a single sample. However, the previous multi-staining devices require complex control lines and valves operated by external power sources, to deliver multiple antibodies separately for a single sample. In addition, most of these devices are composed of hydrophobic materials, causing unreliable results due to the non-specific binding of antibodies. Here, we present a multi-staining chip using hydrophobic valves, which is formed by the partial treatment of 2-hydroxyethyl methacrylate (HEMA). Our chip consists of a circular chamber, divided into six equal fan-shaped regions. Switchable injection ports are located at the center of the chamber and at the middle of the arc of each fan-shaped zone. Thus, our device is beneficial for minimizing the control lines, since pre-treatment solutions flow from the center to outer ports, while six different antibodies are introduced oppositely from the outer ports. Furthermore, hydrophobic narrow channels, connecting the central region and each of the six fan-shaped zones, are closed by capillary effect, thus preventing the fluidic mixing without external power sources. Meanwhile, HEMA treatment on the exterior region results in hydrophobic-to-hydrophilic transition and prevents the non-specific binding of antibodies. For the application, we measured the expression of six different antibodies in a single sample using our device. The expression levels of each antibody highly matched the conventional immunocytochemistry results. Our device enables cancer screening with a small number of antibodies for a single sample.

  10. Integrated injection-locked semiconductor diode laser

    DOEpatents

    Hadley, G.R.; Hohimer, J.P.; Owyoung, A.

    1991-02-19

    A continuous wave integrated injection-locked high-power diode laser array is provided with an on-chip independently-controlled master laser. The integrated injection locked high-power diode laser array is capable of continuous wave lasing in a single near-diffraction limited output beam at single-facet power levels up to 125 mW (250 mW total). Electronic steering of the array emission over an angle of 0.5 degrees is obtained by varying current to the master laser. The master laser injects a laser beam into the slave array by reflection of a rear facet. 18 figures.

  11. Subcritical and supercritical fuel injection and mixing in single and binary species systems

    NASA Astrophysics Data System (ADS)

    Roy, Arnab

    Subcritical and supercritical fluid injection using a single round injector into a quiescent atmosphere comprising single and binary species was investigated using optical diagnostics. Different disintegration and mixing modes are expected for the two cases. In the binary species case, the atmosphere comprised an inert gas of a different composition than that of the injected fluid. In single species case, the atmosphere consisted of the same species as that of the injected fluid. Density values were quantified and density gradient profiles were inferred from the experimental data. A novel method was applied for the detection of detailed structures throughout the entire jet center plane. Various combinations of injectant and chamber conditions were tested and a wide range of density ratios were covered. The subcritical cases demonstrated the importance of surface tension and inertial forces, while the supercritical cases showed no signs of surface tension and, in most situations, resembled the mixing characteristics of a gaseous jet injected into a gaseous environment. A comparison between the single and binary species systems has also been provided. A detailed laser calibration procedure was undertaken to account for the laser absorption through the gas and liquid phases and for fluorescence in the non-linear excitation regime for high laser pulse energy. Core lengths were measured for binary species cases and correlated with visualization results. An eigenvalue approach was taken to determine the location of maximum gradients for determining the core length. Jet divergence angles were also calculated and were found to increase with chamber-to-injectant density ratio for both systems. A model was proposed for the spreading angle dependence on density ratio for both single and binary species systems and was compared to existing theoretical studies and experimental work. Finally, a linear stability analysis was performed for the jet injected into both subcritical and supercritical atmospheres. The subcritical cases showed good correlation with previous and current experimental results. The supercritical solutions, which have not yet been solved earlier by researchers, are found here through an asymptotic solution of the dispersion equation for exceedingly high Weber numbers.

  12. Periconceptional growth hormone treatment alters fetal growth and development in lambs.

    PubMed

    Koch, J M; Wilmoth, T A; Wilson, M E

    2010-05-01

    Research in the area of fetal programming has focused on intrauterine growth restriction. Few studies have attempted to examine programming mechanisms that ultimately lead to lambs with a greater potential for postnatal growth. We previously demonstrated that treatment of ewes with GH at the time of breeding led to an increase in birth weight. Therefore, the objective of this study was to determine the effects of a single injection of sustained-release GH given during the periconceptional period on fetal growth and development and to determine if the GH axis would be altered in these offspring. Estrus was synchronized using 2 injections of PGF(2alpha); at the time of the second injection, ewes assigned to treatment were also given an injection of sustained-release GH. A maternal jugular vein sample was taken weekly to analyze IGF-I as a proxy for GH to estimate the duration of the treatment effect. In ewes treated with GH, IGF-I increased (P < 0.05) by wk 1 and remained elevated until wk 4 postinjection. Lambs were weighed, crown-rump length and abdominal girth were determined, and a plasma sample was collected. In a subset of male lambs, liver, heart, and brain weights were obtained, as well as left and right ventricular wall thicknesses. On postnatal d 100, a subset of ewe lambs were weighed and challenged with an intravenous injection of GHRH. Lambs from treated ewes had increased (P < 0.05) birth weight and abdominal girth compared with control lambs; however, there was no difference in crown-rump length. Expression of GH receptor and IGF-I were increased (P < 0.05) in lambs gestated by GH-treated ewes compared with control ewes. The left ventricular wall was thinner (P < 0.05) from lambs in the GH-treated group compared with control lambs. On postnatal d 100, those ewe lambs born to ewes treated with GH continued to be heavier (P < 0.05) and had no IGF-I response to GHRH challenge. In conclusion, treating ewes with a single injection of GH appeared to alter fetal growth and development. Lambs born to ewes treated with GH were larger at birth and had altered organ development, which may indicate that early maternal GH treatment may lead to permanent changes in the developing fetus. The ewe lambs maintained their growth performance to at least 100 d of postnatal life and appeared to have an altered GH axis, as demonstrated by the altered response to GHRH.

  13. 21 CFR 522.690 - Dinoprost solution.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... licensed veterinarian. (2) Women of child-bearing age, asthmatics, and persons with bronchial and other.... 1 mg per 100 pounds of body weight as a single intramuscular injection. (ii) Indications. For its... nonlactating dairy heifers—(A) Amount. 25 mg as a single intramuscular injection. (B) Indications. For...

  14. Ambiguity in measuring matrix diffusion with single-well injection/recovery tracer tests

    USGS Publications Warehouse

    Lessoff, S.C.; Konikow, Leonard F.

    1997-01-01

    Single-well injection/recovery tracer tests are considered for use in characterizing and quantifying matrix diffusion in dual-porosity aquifers. Numerical modeling indicates that neither regional drift in homogeneous aquifers, nor heterogeneity in aquifers having no regional drift, nor hydrodynamic dispersion significantly affects these tests. However, when drift is coupled simultaneously with heterogeneity, they can have significant confounding effects on tracer return. This synergistic effect of drift and heterogeneity may help explain irreversible flow and inconsistent results sometimes encountered in previous single-well injection/recovery tracer tests. Numerical results indicate that in a hypothetical single-well injection/recovery tracer test designed to demonstrate and measure dual-porosity characteristics in a fractured dolomite, the simultaneous effects of drift and heterogeneity sometimes yields responses similar to those anticipated in a homogeneous dual-porosity formation. In these cases, tracer recovery could provide a false indication of the occurrence of matrix diffusion. Shortening the shut-in period between injection and recovery periods may make the test less sensitive to drift. Using multiple tracers having different diffusion characteristics, multiple tests having different pumping schedules, and testing the formation at more than one location would decrease the ambiguity in the interpretation of test data.

  15. Hydrodynamic injection with pneumatic valving for microchip electrophoresis with total analyte utilization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sun, Xuefei; Kelly, Ryan T.; Danielson, William F.

    2011-04-26

    A novel hydrodynamic injector that is directly controlled by a pneumatic valve has been developed for reproducible microchip capillary electrophoresis (CE) separations. The poly(dimethylsiloxane) (PDMS) devices used for evaluation comprise a separation channel, a side channel for sample introduction, and a pneumatic valve aligned at the intersection of the channels. A low pressure (≤ 3 psi) applied to the sample reservoir is sufficient to drive sample into the separation channel. The rapidly actuated pneumatic valve enables injection of discrete sample plugs as small as ~100 pL for CE separation. The injection volume can be easily controlled by adjusting the intersectionmore » geometry, the solution back pressure and the valve actuation time. Sample injection could be reliably operated at different frequencies (< 0.1 Hz to >2 Hz) with good reproducibility (peak height relative standard deviation ≤ 3.6%) and no sampling biases associated with the conventional electrokinetic injections. The separation channel was dynamically coated with a cationic polymer, and FITC-labeled amino acids were employed to evaluate the CE separation. Highly efficient (≥ 7.0 × 103 theoretical plates for the ~2.4 cm long channel) and reproducible CE separations were obtained. The demonstrated method has numerous advantages compared with the conventional techniques, including repeatable and unbiased injections, no sample waste, high duty cycle, controllable injected sample volume, and fewer electrodes with no need for voltage switching. The prospects of implementing this injection method for coupling multidimensional separations, for multiplexing CE separations and for sample-limited bioanalyses are discussed.« less

  16. Immunohistochemical and ultrastructural changes in rat fat tissue related to the local hCG injection.

    PubMed

    Tunç, E; Erdogan, D; Calgüner, E; Göktas, G; Elmas, Ç; Gözil, R; Bahçelioglu, M; Öktem, H

    2013-11-01

    Recently, it has been observed that weight loss is accelerated by human chorionic gonadotropin (hCG) hormone preparation used for hypothalamic dysfunction in obesity treatment in both sexes. hCG is also used for in vitro fertilization and in treatment of hypogonadotropic hypogonadism. Our aim was to observe the ultrastructural changes caused by local injections of hCG made for purpose of weight loss and to present them to inform those receiving such therapy. In our study, 10 obese female, 10 male obese, 10 non-obese female and 10 non-obese male rats were used. In each group, single dose of subcutaneous hCG injection has been applied to 7 rats for 5 weeks in 5 days of the week, and placebo has been applied to the remaining 3 rats. Following the injection, the tissues were evaluated morphologically, immunohistochemically and ultrastructurally. Leptin immunoreactivity was similar in all groups. When the adipose tissue samples were examined under electron microscope, they were observed to exhibit normal structure with organelles located around the nuclei and nucleoli, and no distinctive features were found among the groups. Administering hCG in addition to diet had no advantage on weight reduction in rats.

  17. Usefulness of intra-articular botulinum toxin injections. A systematic review.

    PubMed

    Khenioui, Hichem; Houvenagel, Eric; Catanzariti, Jean François; Guyot, Marc Alexandre; Agnani, Olivier; Donze, Cécile

    2016-03-01

    Botulinum toxin is a proven and widely used treatment for numerous conditions characterized by excessive muscular contractions. Recent studies have assessed the analgesic effect of botulinum toxin in joint pain and started to unravel its mechanisms. We searched the international literature via the Medline database using the term "intraarticular botulinum toxin injection" combined with any of the following terms: "knee", "ankle", "shoulder", "osteoarthritis", "adhesive capsulitis of the shoulder". Of 16 selected articles about intraarticular botulinum toxin injections, 7 were randomized controlled trials done in patients with osteoarthritis, adhesive capsulitis of the shoulder, or chronic pain after joint replacement surgery. Proof of anti-nociceptive effects was obtained in some of these indications and the safety and tolerance profile was satisfactory. The studies are heterogeneous. The comparator was usually a glucocorticoid or a placebo; a single study used hyaluronic acid. Pain intensity was the primary outcome measure. The number of randomized trials and sample sizes are too small to provide a satisfactory level of scientific evidence or statistical power. Unanswered issues include the effective dosage and the optimal dilution and injection modalities of botulinum toxin. Copyright © 2015 Société française de rhumatologie. Published by Elsevier SAS. All rights reserved.

  18. Recovery of rat muscle size but not function more than 1 year after a single botulinum toxin injection.

    PubMed

    Ward, Samuel R; Minamoto, Viviane B; Suzuki, Kentaro P; Hulst, Jonah B; Bremner, Shannon N; Lieber, Richard L

    2018-03-01

    Neurotoxin injection is used to treat a wide variety of neuromuscular disorders. The purpose of this study was to measure the functional and structural properties of botulinum toxin-injected adult rat skeletal muscle over nearly the entire lifespan. Ten groups of animals were subjected to either neurotoxin injection [Botox, Type A (BT-A); Allergan, Irvine, California] or saline solution injection. Neurotoxin-injected animals (n = 90) were analyzed at different time-points: 1 week; 1 month; 3 months; 6 months; 12 months; or 18 months. In spite of the recovery of structural features, such as muscle mass and fiber area, dorsiflexion torque production remained significantly depressed by 25%, even at 12 months after neurotoxin injection. The data demonstrate that, after a single BT-A injection, although gross muscle morphology recovered over a 12-month time period, loss of contractile function did not recover. Muscle Nerve 57: 435-441, 2018. © 2017 Wiley Periodicals, Inc.

  19. Sustained neuroprotection from a single intravitreal injection of PGJ₂ in a nonhuman primate model of nonarteritic anterior ischemic optic neuropathy.

    PubMed

    Miller, Neil R; Johnson, Mary A; Nolan, Theresa; Guo, Yan; Bernstein, Alexander M; Bernstein, Steven L

    2014-10-08

    Prostaglandin J₂ (PGJ₂) is neuroprotective in a murine model of nonarteritic anterior ischemic optic neuropathy (NAION). After assessing for potential toxicity, we evaluated the efficacy of a single intravitreal (IVT) injection of PGJ₂ in a nonhuman primate model of NAION (pNAION). We assessed PGJ₂ toxicity by administering it as a single high-dose intravenous (IV) injection, consecutive daily high-dose IV injections, or a single IVT injection in one eye of five adult rhesus monkeys. To assess efficacy, we induced pNAION in one eye of five adult male rhesus monkeys using a laser-activated rose bengal induction method. We then injected the eye with either PGJ₂ or phosphate-buffered saline (PBS) intravitreally immediately or 5 hours post induction. We performed a clinical assessment, optical coherence tomography, electrophysiological testing, fundus photography, and fluorescein angiography in all animals prior to induction and at 1 day, 1 week, 2 weeks, and 4 weeks after induction. Following analysis of the first eye, we induced pNAION in the contralateral eye and then injected either PGJ₂ or PBS. We euthanized all animals 5 weeks after final assessment of the fellow eye and performed both immunohistochemical and light and electron microscopic analyses of the retina and optic nerves. PGJ₂ caused no permanent systemic toxicity regardless of the amount injected or route of delivery, and there was no evidence of any ocular toxicity with the dose of PGJ₂ used in efficacy studies. Transient reduction in the amplitudes of the visual evoked potentials and the N95 component of the pattern electroretinogram (PERG) occurred after both IV and IVT administration of high doses of PGJ₂; however, the amplitudes returned to normal in all animals within 1 week. In all eyes, a single IVT dose of PGJ₂ administered immediately or shortly after induction of pNAION resulted in a significant reduction of clinical, electrophysiological, and histological damage compared with vehicle-injected eyes (P = 0.03 for both VEP and PERG; P = 0.05 for axon counts). In nonhuman primates, PGJ₂ administered either intravenously or intravitreally produces no permanent toxicity at even four times the dose given for neuroprotection. Additionally, a single IVT dose of PGJ₂ is neuroprotective when administered up to 5 hours after induction of pNAION. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.

  20. The efficacy of multiple versus single hyaluronic acid injections: a systematic review and meta-analysis.

    PubMed

    Concoff, Andrew; Sancheti, Parag; Niazi, Faizan; Shaw, Peter; Rosen, Jeffrey

    2017-12-21

    Intra-articular hyaluronic acid (IA-HA) is a common therapy used to treat knee pain and suppress knee inflammation in knee osteoarthritis (OA), typically prescribed in regimens ranging from a single injection to 5 weekly injections given once weekly. We conducted a systematic review to determine the efficacy of IA-HA, with subgroup analyses to explore the differences in knee pain and adverse events (AEs) across different dosing regimens. We conducted a systematic search of the literature to identify studies evaluating IA-HA for the management of knee OA compared to IA-saline. Primary outcome measure was the mean knee pain score at 13 Weeks (3 months) or 26 weeks (6 months). Secondary outcome was the number of treatment-related AEs and treatment-related serious adverse events (SAEs). We evaluated differences in levels of pain and AEs/SAEs between dosing regimens compared to IA-Saline. Thirty articles were included. Overall, IA-HA injections were associated with less knee pain compared to IA-Saline injections for all dosing regimens. 2-4 injections of IA-HA vs. IA-Saline produced the largest effect size at both 3-months and 6-months (Standard mean difference [SMD] = -0.76; -0.98 to -0.53, 95% CI, P < 0.00001, and SMD = -0.36; -0.63 to -0.09 95% CI, P = 0.008, respectively). Additionally, single injection studies yielded a non-significant treatment effect at 3 and 6 months, while ≥5 5 injections demonstrated a significant improvement in pain only at 6 months. Five or more injections of IA-HA were associated with a higher risk of treatment-related AEs compared to IA-Saline (Risk ratio [RR] = 1.67; 1.09 to 2.56 95% CI, p = 0.02), which was a result not seen within the 1 and 2-4 injection subgroups. Overall, 2-4 and ≥5 injection regimens provided pain relief over IA-Saline, while single injection did not. Intra-articular injections of HA used in a 2-4 injection treatment regimen provided the greatest benefit when compared to IA-Saline with respect to pain improvement in patients with knee OA, and was generally deemed safe with few to no treatment-related AEs reported across studies. Future research is needed to directly compare these treatment regimens.

  1. Characterization of a novel particle into liquid sampler for analysis of single fluorescent aerosol particles through capillary electrophoresis.

    PubMed

    Tang, Hao; Hiemstra, Scott; Thompson, Jonathan E

    2011-09-19

    An approach to sample and analyze single aerosolized droplets (<10 nL) of solutions containing fluorescein isothiocyanate (FITC) labeled glycine (GLY) and glutamic acid (GLU) is demonstrated. The sampling approach is based on inertial impaction in which the sample particle is accelerated through a nozzle and directly into a small drop of buffered solution (20 mM borate, pH=10) suspended at the end of a coaxial tube of stainless steel and a fused silica capillary. A spherical light scattering cell and laser (λ=532 nm) is used to detect the arrival of particles at the buffered droplet. Upon dissolution and/or mixing, a portion of the sample is injected onto the fused silica capillary for subsequent chemical analysis by capillary electrophoresis (CE) and detection by laser-induced fluorescence (LIF). It was found that the inertial impaction approach sampled particles >1 μm diameter with an efficiency of 80% or greater. At 15 kV applied potential, the FITC conjugates of GLY and GLU could be resolved in less than 120 s allowing qualitative analysis of the contents of single dispersed particles. However, the extent to which the sample is diluted into the buffer droplet varied significantly on a per-particle basis that caused >80% R.S.D. in fluorescence peak heights. This aspect of the method would necessitate the use of internal standards for quantitative analysis of materials present within the particles. It is envisaged that further improvements to the device described may ultimately lead to analysis of the contents of single particles dispersed in earth's atmosphere. Copyright © 2011 Elsevier B.V. All rights reserved.

  2. Development of an analytical solution for thermal single-well injection-withdrawal tests in horizontally fractured reservoirs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jung, Yoojin

    In this study, we have developed an analytical solution for thermal single-well injection-withdrawal tests in horizontally fractured reservoirs where fluid flow through the fracture is radial. The dimensionless forms of the governing equations and the initial and boundary conditions in the radial flow system can be written in a form identical to those in the linear flow system developed by Jung and Pruess [Jung, Y., and K. Pruess (2012), A Closed-Form Analytical Solution for Thermal Single-Well Injection-Withdrawal Tests, Water Resour. Res., 48, W03504, doi:10.1029/2011WR010979], and therefore the analytical solutions developed in Jung and Pruess (2012) can be applied to computemore » the time dependence of temperature recovery at the injection/withdrawal well in a horizontally oriented fracture with radial flow.« less

  3. 21 CFR 522.770 - Doramectin.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... a single subcutaneous or intramuscular injection. Do not slaughter cattle within 35 days of..., sucking lice, and mange mites. (iii) Limitations. Administer as a single intramuscular injection. Do not... 21 Food and Drugs 6 2011-04-01 2011-04-01 false Doramectin. 522.770 Section 522.770 Food and Drugs...

  4. 21 CFR 522.770 - Doramectin.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... a single subcutaneous or intramuscular injection. Do not slaughter cattle within 35 days of..., sucking lice, and mange mites. (iii) Limitations. Administer as a single intramuscular injection. Do not... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Doramectin. 522.770 Section 522.770 Food and Drugs...

  5. Ultrasound-guided Interdigital Neuroma Injections: Short-term Clinical Outcomes after a Single Percutaneous Injection—Preliminary Results

    PubMed Central

    Adler, Ronald S.; Ciavarra, Gina A.; Pavlov, Helene

    2006-01-01

    Purpose To describe the procedure of ultrasound-guided Morton’s neuroma and recurrent stump neuroma injections and early clinical outcomes after a single injection. Materials and Methods Retrospective review of 44 percutaneous ultrasound-guided neuroma injections in 24 patients who had completed clinical outcomes questionnaires. A 10-point pain scale [scale of 1 (no pain) to 10 (severe pain)] in a 7-day pain log format was distributed to patients at the time percutaneous neuroma injection was performed. Results Neuromas were clearly visualized with sonography as hypoechoic nodules and were distinguishable from other causes of forefoot pain, such as metatarsophalangeal joint synovitis and intermetatarsal bursae. The sizes of the neuromas injected ranged between 4 and 19 mm. Postinjection, all neuromas displayed increased echogenicity and/or the appearance of fluid surrounding it, confirming localization of the therapeutic mixture. We arbitrarily subdivided the pain ratings into symptomatic (greater than 4) and asymptomatic (less than or equal to 4) for statistical analysis. Average pain level pre injection was 5.2 and average pain level was 3.7 at 7 days post single injection, with 62% of the initially symptomatic patients asymptomatic on day 7 (p < 0.000001). Overall, 76% of the total number of neuromas injected once were asymptomatic on day 7. Conclusion Ultrasound can be used to accurately target Morton’s neuromas and, therefore, appropriately direct therapeutic interventions, with good short-term clinical results. PMID:18751769

  6. Film cooling effectiveness and heat transfer with injection through holes

    NASA Technical Reports Server (NTRS)

    Eriksen, V. L.

    1971-01-01

    An experimental investigation of the local film cooling effectiveness and heat transfer downstream of injection of air through discrete holes into a turbulent boundary layer of air on a flat plate is reported. Secondary air is injected through a single hole normal to the main flow and through both a single hole and a row of holes spaced at three diameter intervals with an injection angle of 35 deg to the main flow. Two values of the mainstream Reynolds number are used; the blowing rate is varied from 0.1 to 2.0. Photographs of a carbon dioxide-water fog injected into the main flow at an angle of 90 deg are also presented to show interaction between the jet and mainstream.

  7. A laser-induced-fluorescence visualization study of transverse, sonic fuel injection in a nonreacting supersonic combustor

    NASA Technical Reports Server (NTRS)

    Mcdaniel, J. C.; Graves, J., Jr.

    1986-01-01

    The present paper reports work which has been conducted in the first phase of a research program which is to provide a data base of spatially-resolved measurements in nonreacting supersonic combustors. In the measurements, a nonintrusive diagnostic technique based on the utilization of laser-induced fluorescence (LIF) is employed. The reported work had the objective to conduct LIF visualization studies of the injection of a simulated fuel into a Mach 2.07 airstream for comparison with corresponding numerical calculations. Attention is given to injection from a single orifice into a constant-area duct, injection from a single orifice behind a rearward-facing step, and injection from staged orifices behind a rearward-facing step.

  8. Injection molding of iPP samples in controlled conditions and resulting morphology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sessa, Nino, E-mail: ninosessa.ns@gmail.com; De Santis, Felice, E-mail: fedesantis@unisa.it; Pantani, Roberto, E-mail: rpantani@unisa.it

    2015-12-17

    Injection molded parts are driven down in size and weight especially for electronic applications. In this work, an investigation was carried out on the process of injection molding of thin iPP samples and on the morphology of these parts. Melt flow in the mold cavity was analyzed and described with a mathematical model. Influence of mold temperature and injection pressure was analyzed. Samples orientation was studied using optical microscopy.

  9. Sulforaphane Modulates Joint Inflammation in a Murine Model of Complete Freund's Adjuvant-Induced Mono-Arthritis.

    PubMed

    Silva Rodrigues, João Francisco; Silva E Silva, Cristiane; França Muniz, Thayanne; de Aquino, Alana Fernanda; Neuza da Silva Nina, Larissa; Fialho Sousa, Nagila Caroline; Nascimento da Silva, Luis Claudio; de Souza, Breno Glaessner Gomes Fernandes; da Penha, Tatiana Aranha; Abreu-Silva, Ana Lúcia; de Sá, Joicy Cortez; Soares Fernandes, Elizabeth; Grisotto, Marcos Augusto Grigolin

    2018-04-24

    Rheumatoid arthritis (RA) is characterized by inflammation of one or more joints, and affects ~1% of the adult population worldwide. Sulforaphane (SFN) is a natural compound that has been suggested as an antioxidant. Here, SFN’s effects were evaluated in a murine mono-arthritis model. Mono-arthritis was induced in mice by a single intra-articular injection of Complete Freund’s Adjuvant (CFA-10 µg/joint, in 10 µL) into the ipsilateral joint. The contralateral joint received an equal volume of PBS. On the 4th day post-joint inflammation induction, animals received either SFN (10 mg/kg) or vehicle (3% DMSO in saline), intraperitoneally (i.p.), twice a day for 3 days. Joint swelling and secondary mechanical allodynia and hyperalgesia were evaluated over 7 days post-CFA. After this period, animals were culled and their blood and synovial fluid samples were collected for analysis of cell populations, cytokine release and thioredoxin reductase (TrxR) activity. Knee joint samples were also collected for histology. SFN reduced joint swelling and damage whilst increasing the recruitment of Ly6C⁺ and Ly6G⁺ cells to CFA-injected joints. SFN-treated animals presented down-regulation of CD11b and CD62L on synovial fluid Ly6G⁺ cells. Synovial fluid samples obtained from CFA-injected joints and plasma samples of SFN-treated mice presented higher levels of IL-6 and increased activity of TrxR, in comparison with controls. These results indicate that SFN reduces knee joint damage by modulating cell activation/migration to the joints, cytokine production and increasing the activity of TrxR, and therefore, may represent an alternative treatment to joint inflammation.

  10. Development of a highly sensitive methodology for quantitative determination of fexofenadine in a microdose study by multiple injection method using ultra-high performance liquid chromatography with tandem mass spectrometry.

    PubMed

    Tanaka, Yukari; Yoshikawa, Yutaka; Yasui, Hiroyuki

    2012-01-01

    An ultra high-sensitivity method for quantifying fexofenadine concentration in rat plasma samples by multiple injection method (MIM) was developed for a microdose study. In this study, MIM involved continuous injections of multiple samples containing the single compound into a column of the ultra-HPLC (UHPLC) system, and then, temporary trapping of the analyte at the column head. This was followed by elution of the compound from the column and detection by mass spectrometer. Fexofenadine, used as a model compound in this study, was extracted from the plasma samples by a protein precipitation method. Chromatographic separation was achieved on a reversed-phase C18 column by using a gradient method with 0.1% formic acid and 0.1% formic acid in acetonitrile as the mobile phase. The analyte was quantified in the positive-ion electrospray ionization mode using selected reaction monitoring. In this study, the analytical time per fexofenadine sample was approximately 2 min according to the UHPLC system. The method exhibited the linear dynamic ranges of 5-5000 pg/mL for fexofenadine in rat plasma. The intra-day precisions were from 3.2 to 8.7% and the accuracy range was 95.2-99.3%. The inter-day precisions and accuracies ranged from 3.5 to 8.4% and from 98.6 to 102.6%, respectively. The validated MIM was successfully applied to a microdose study in the rats that received oral administration of 100 µg/kg fexofenadine. We suggest that this method might be beneficial for the quantification of fexofenadine concentrations in a microdose clinical study.

  11. Two injection digital block versus single subcutaneous palmar injection block for finger lacerations.

    PubMed

    Okur, O M; Şener, A; Kavakli, H Ş; Çelik, G K; Doğan, N Ö; Içme, F; Günaydin, G P

    2017-12-01

    We aimed to compare two digital nerve block techniques in patients due to traumatic digital lacerations. This was a randomized-controlled study designed prospectively in the emergency department of a university-based training and research hospital. Randomization was achieved by sealed envelopes. Half of the patients were randomised to traditional (two-injection) digital nerve block technique while single-injection digital nerve block technique was applied to the other half. Score of pain due to anesthetic infiltration and suturing, onset time of total anesthesia, need for an additional rescue injection were the parameters evaluated with both groups. Epinephrin added lidocaine hydrochloride preparation was used for the anesthetic application. Visual analog scale was used for the evaluation of pain scores. Outcomes were compared by using Mann-Whitney U test and Student t-test. Fifty emergency department patients ≥18 years requiring digital nerve block were enrolled in the study. Mean age of the patients was 33 (min-max: 19-86) and 39 (78 %) were male. No statistically significant difference was found between the two groups in terms of our main parameters; anesthesia pain score, suturing pain score, onset time of total anesthesia and rescue injection need. Single injection volar digital nerve block technique is a suitable alternative for digital anesthesias in emergency departments.

  12. Clinical Outcomes of Intravitreal Preservative-Free Triamcinolone Preparation (Triesence®) for Cystoid Macular Oedema and Inflammation in Patients with Uveitis.

    PubMed

    Steeples, Laura R; Anand, Nitin; Moraji, Jiten; Jones, Nicholas P

    2017-03-20

    To assess the outcomes of intravitreal benzyl alcohol-free triamcinolone acetonide suspension in uveitis-related macular oedema. Single-center retrospective cohort study of 66 injections to 44 eyes of 40 patients. Uveitis diagnosis, systemic and local therapy, intraocular pressure (IOP), central retinal thickness (CRT), number of injections, time to re-injection and side-effects were noted during 6-months minimum follow-up. Sixty eight percent of eyes received a single injection. 18% required 2 injections, and 13% received ≥3 injections with mean time to second and third injections of 25.5 and 52.7 weeks, respectively. 90% of injections were unilateral. Mean CRT reduced, and by 12-weeks visual acuity improvement >0.3logMar was achieved in 46%. Cataract progression (47%) and IOP>21 mmHg (45%) were the commonest adverse events. Preservative-free triamcinolone is an additional option for uveitis-related macular oedema, particularly in unilateral cases, with favorable CRT and visual outcomes. Repeat injections may be necessary, and the period of efficacy varies between eyes.

  13. Inductively coupled plasma mass spectrometry with a twin quadrupole instrument using laser ablation sample introduction and monodisperse dried microparticulate injection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Allen, Lloyd A.

    1996-10-17

    The focus of this dissertation is the use of a twin quadrupole inductively coupled plasma mass spectrometer (ICP-MS) for the simultaneous detection of two m/z values. The twin quadrupole ICP-MS is used with laser ablation sample introduction in both the steady state (10 Hz) and single pulse modes. Steady state signals are highly correlated and the majority of flicker noise cancels when the ratio is calculated. Using a copper sample, the isotope ratio 63Cu +/ 65Cu + is measured with a relative standard deviation (RSD) of 0.26%. Transient signals for single laser pulses are also obtained. Copper isotope ratio measurementsmore » for several laser pulses are measured with an RSD of 0.85%. Laser ablation (LA) is used with steel samples to assess the ability of the twin quadrupole ICP-MS to eliminate flicker noise of minor components of steel samples. Isotopic and internal standard ratios are measured in the first part of this work. The isotope ratio 52Cr +/ 53Cr + (Cr present at 1.31 %) can be measured with an RSD of 0.06 % to 0.1 %. For internal standard elements, RSDs improve from 1.9 % in the Cr + signal to 0.12% for the ratio of 51V + to 52Cr +. In the second part of this work, one mass spectrometer is scanned while the second channel measures an individual m/z value. When the ratio of these two signals is calculated, the peak shapes in the mass spectrum are improved significantly. Pulses of analyte and matrix ions from individual drops are measured simultaneously using the twin quadrupole ICP-MS with monodisperse dried microparticulate injection (MDMI). At modest Pb concentrations (500 ppm), a shoulder on the leading edge of the Li + signal becomes apparent. Space charge effects are consistent with the disturbances seen.« less

  14. Mechanical Weakening during Fluid Injection in Critically Stressed Sandstones with Acoustic Monitoring

    NASA Astrophysics Data System (ADS)

    David, C.; Dautriat, J. D.; Sarout, J.; Macault, R.; Bertauld, D.

    2014-12-01

    Water weakening is a well-known phenomenon which can lead to subsidence during the production of hydrocarbon reservoirs. The example of the Ekofisk oil field in the North Sea has been well documented for years. In order to assess water weakening effects in reservoir rocks, previous studies have focused on changes in the failure envelopes derived from mechanical tests conducted on rocks saturated either with water or with inert fluids. However, little attention has been paid so far on the mechanical behaviour during the fluid injection stage, like in enhanced oil recovery operations. We studied the effect of fluid injection on the mechanical behaviour of Sherwood sandstone, a weakly-consolidated sandstone sampled at Ladram Bay in UK. In order to highlight possible weakening effects, water and inert oil have been injected into critically-loaded samples to assess their effect on strength and elastic properties and to derive the acoustic signature of the saturation front for each fluid. The specimens were instrumented with 16 ultrasonic P-wave transducers for both passive and active acoustic monitoring during fluid injection and loading. After conducting standard triaxial tests on three samples saturated with air, water and oil respectively, mechanical creep tests were conducted on dry samples loaded at 80% of the compressive strength of the dry rock. While these conditions are kept constant, a fluid is injected at the bottom end of the sample with a low back pressure (0.5 MPa) to minimize effective stress variations during injection. Both water and oil were used as the injected pore fluid in two experiments. As soon as the fluids start to flow into the samples, creep is taking place with a much higher strain rate for water injection compared to oil injection. A transition from secondary creep to tertiary creep is observed in the water injection test whereas in the oil injection test no significant creep acceleration is observed after one pore volume of oil was injected. The most remarkable difference is that water injection induces mechanical instability and failure, whereas oil injection does not. This was confirmed by the analysis of acoustic emissions activity and post-mortem sample imaging using CT scan. Contrasting evolutions of the P wave velocity during the fluid front propagation were also observed in both experiments.

  15. Helium ionization detection apparatus

    NASA Technical Reports Server (NTRS)

    Nagai, R.

    1984-01-01

    In a gas chromatograph apparatus comprising a gas supply (He carrier gas), a sample injection apparatus, a chromatograph column, a He ion detector, and connecting tubes, a foreign gas (other than He) injection apparatus is installed between the sample injection apparatus and the detector. Mixing of the sample gas and foreign gas takes place readily, the sample gas is always maintained at a stable concentrator range, and accurate measurements are possible, especially at low sample gas concentrations.

  16. Dynamic ultrasonic nebulisation extraction coupled with headspace ionic liquid-based single-drop microextraction for the analysis of the essential oil in Forsythia suspensa.

    PubMed

    Yang, Jinjuan; Wei, Hongmin; Teng, Xiane; Zhang, Hanqi; Shi, Yuhua

    2014-01-01

    Ionic liquids have attracted much attention as an extraction solvent instead of traditional organic solvent in single-drop microextraction. However, non-volatile ionic liquids are difficult to couple with gas chromatography. Thus, the following injection system for the determination of organic compounds is described. To establish an environmentally friendly, simple, and effective extraction method for preparation and analysis of the essential oil from aromatic plants. The dynamic ultrasonic nebulisation extraction was coupled with headspace ionic liquid-based single-drop microextraction(UNE-HS/IL/SDME)for the extraction of essential oils from Forsythia suspense fruits. After 13 min of extraction for 50 mg sample, the extracts in ionic liquid were evaporated rapidly in the gas chromatography injector through a thermal desorption unit (5 s). The traditional extraction method was carried out for comparative study. The optimum conditions were: 3 μL of 1-methyl-3-octylimidazolium hexafluorophosphate was selected as the extraction solvent, the sample amount was 50 mg, the flow rate of purging gas was 200 mL/min, the extraction time was 13 min, the injection volume was 2 μL, and the thermal desorption temperature and time were 240 °C and 5 s respectively. Comparing with hydrodistillation (HD), the proposed method was environment friendly and efficient. The proposed method is environmentally friendly, time saving, with high efficiency and low consumption. It would extend the application range of the HS/SDME and would be useful especially for aromatic plants analysis. Copyright © 2013 John Wiley & Sons, Ltd.

  17. A Single Intravitreal Injection of Ranibizumab Provides No Neuroprotection in a Nonhuman Primate Model of Moderate-to-Severe Nonarteritic Anterior Ischemic Optic Neuropathy

    PubMed Central

    Miller, Neil R.; Johnson, Mary A.; Nolan, Theresa; Guo, Yan; Bernstein, Steven L.

    2015-01-01

    Purpose Ranibizumab, a vascular endothelial growth factor-antagonist, is said to be neuroprotective when injected intravitreally in patients with nonarteritic anterior ischemic optic neuropathy (NAION). We evaluated the efficacy of a single intravitreal (IVT) injection of ranibizumab in a nonhuman primate model of NAION (pNAION). Methods We induced pNAION in one eye of four adult male rhesus monkeys using a laser-activated rose Bengal induction method. We then immediately injected the eye with either ranibizumab or normal saline (NS) intravitreally. We performed a clinical assessment, optical coherence tomography, electrophysiological testing, fundus photography, and fluorescein angiography in three of the animals (one animal developed significant retinal hemorrhages and, therefore, could not be analyzed completely) prior to induction, 1 day and 1, 2, and 4 weeks thereafter. Following the 4-week analysis of the first eye, we induced pNAION in the contralateral eye and then injected either ranibizumab or NS, whichever substance had not been injected in the first eye. We euthanized all animals 5 to 12 weeks after the final assessment of the second eye and performed both immunohistochemical and light and electron microscopic analyses of the retina and optic nerves of both eyes. Results A single IVT dose of ranibizumab administered immediately after induction of pNAION resulted in no significant reduction of clinical, electrophysiological, or histologic damage compared with vehicle-injected eyes. Conclusions A single IVT dose of ranibizumab is not neuroprotective when administered immediately after induction of pNAION. PMID:26624498

  18. Evaluation of a Murine Single-Blood-Injection SAH Model

    PubMed Central

    Sommer, Clemens; Steiger, Hans-Jakob; Schneider, Toni; Hänggi, Daniel

    2014-01-01

    The molecular pathways underlying the pathogenesis after subarachnoid haemorrhage (SAH) are poorly understood and continue to be a matter of debate. A valid murine SAH injection model is not yet available but would be the prerequisite for further transgenic studies assessing the mechanisms following SAH. Using the murine single injection model, we examined the effects of SAH on regional cerebral blood flow (rCBF) in the somatosensory (S1) and cerebellar cortex, neuro-behavioural and morphological integrity and changes in quantitative electrocorticographic and electrocardiographic parameters. Micro CT imaging verified successful blood delivery into the cisterna magna. An acute impairment of rCBF was observed immediately after injection in the SAH and after 6, 12 and 24 hours in the S1 and 6 and 12 hours after SAH in the cerebellum. Injection of blood into the foramen magnum reduced telemetric recorded total ECoG power by an average of 65%. Spectral analysis of ECoGs revealed significantly increased absolute delta power, i.e., slowing, cortical depolarisations and changes in ripples and fast ripple oscillations 12 hours and 24 hours after SAH. Therefore, murine single-blood-injection SAH model is suitable for pathophysiological and further molecular analysis following SAH. PMID:25545775

  19. Focal Activation of Cells by Plasmon Resonance Assisted Optical Injection of Signaling Molecules

    PubMed Central

    2015-01-01

    Experimental methods for single cell intracellular delivery are essential for probing cell signaling dynamics within complex cellular networks, such as those making up the tumor microenvironment. Here, we show a quantitative and general method of interrogation of signaling pathways. We applied highly focused near-infrared laser light to optically inject gold-coated liposomes encapsulating bioactive molecules into single cells for focal activation of cell signaling. For this demonstration, we encapsulated either inositol trisphosphate (IP3), an endogenous cell signaling second messenger, or adenophostin A (AdA), a potent analogue of IP, within 100 nm gold-coated liposomes, and injected these gold-coated liposomes and their contents into the cytosol of single ovarian carcinoma cells to initiate calcium (Ca2+) release from intracellular stores. Upon optical injection of IP3 or AdA at doses above the activation threshold, we observed increases in cytosolic Ca2+ concentration within the injected cell initiating the propagation of a Ca2+ wave throughout nearby cells. As confirmed by octanol-induced inhibition, the intercellular Ca2+ wave traveled via gap junctions. Optical injection of gold-coated liposomes represents a quantitative method of focal activation of signaling cascades of broad interest in biomedical research. PMID:24877558

  20. Multidose Botulinum Toxin A for Intralaryngeal Injection: A Cost Analysis.

    PubMed

    Gilbert, Mark R; Young, VyVy N; Smith, Libby J; Rosen, Clark A

    2018-01-04

    Botulinum toxin A (BtxA) injection is the mainstay treatment for laryngeal dystonias. BtxA product labeling states that reconstituted toxin should be used within 4 hours on a single patient despite several studies that have demonstrated multidose BtxA to be safe and effective. Many insurance carriers mandate the use of an outside pharmacy which necessitates a single-use approach. This study compares the cost savings of multidose BtxA for laryngeal dystonia compared to single-use. This is a retrospective review and projected cost savings analysis. Records and billing information were reviewed for patients receiving BtxA for intralaryngeal injection at a single laryngology division in 2015. Inclusion criteria included CPT 64617 or J0585; exclusion criteria included CPT 64616. The price of BtxA 100 unit vial for calculation was $670. A total of 142 patients were seen for intralaryngeal BtxA injection resulting in 337 visits over 1 year. The average BtxA dose per visit was 2.86 units with an average of 3.06 procedure visits per year. The calculated cost of BtxA treatment using a single vial approach was found to be $2,050 per patient per year. If billed instead for $7/unit with 5 units wastage charge per visit, the yearly per patient charge is $168. Single vial-use of BtxA injection thus represents a 1,118% price increase versus multidose use. When estimated for yearly prevalence of spasmodic dysphonia, multidose BtxA use would save almost $100 million annually. Multidose botulinum toxin A application utilizing per unit billing is significantly less expensive than per single-use vial billing and would save the health-care system significant amount of money without any sacrifice in safety or effectiveness. Copyright © 2018. Published by Elsevier Inc.

  1. Advanced diesel electronic fuel injection and turbocharging

    NASA Astrophysics Data System (ADS)

    Beck, N. J.; Barkhimer, R. L.; Steinmeyer, D. C.; Kelly, J. E.

    1993-12-01

    The program investigated advanced diesel air charging and fuel injection systems to improve specific power, fuel economy, noise, exhaust emissions, and cold startability. The techniques explored included variable fuel injection rate shaping, variable injection timing, full-authority electronic engine control, turbo-compound cooling, regenerative air circulation as a cold start aid, and variable geometry turbocharging. A Servojet electronic fuel injection system was designed and manufactured for the Cummins VTA-903 engine. A special Servojet twin turbocharger exhaust system was also installed. A series of high speed combustion flame photos was taken using the single cylinder optical engine at Michigan Technological University. Various fuel injection rate shapes and nozzle configurations were evaluated. Single-cylinder bench tests were performed to evaluate regenerative inlet air heating techniques as an aid to cold starting. An exhaust-driven axial cooling air fan was manufactured and tested on the VTA-903 engine.

  2. The CarbFix Pilot Project in Iceland - CO2 capture and mineral storage in basaltic rocks

    NASA Astrophysics Data System (ADS)

    Sigurdardottir, H.; Sigfusson, B.; Aradottir, E. S.; Gunnlaugsson, E.; Gislason, S. R.; Alfredsson, H. A.; Broecker, W. S.; Matter, J. M.; Stute, M.; Oelkers, E.

    2010-12-01

    The overall objective of the CarbFix project is to develop and optimize a practical and cost-effective technology for capturing CO2 and storing it via in situ mineral carbonation in basaltic rocks, as well as to train young scientist to carry the corresponding knowledge into the future. The project consists of a field injection of CO2 charged water at the Hellisheidi geothermal power plant in SW Iceland, laboratory experiments, numerical reactive transport modeling, tracer tests, natural analogue and cost analysis. The CO2 injection site is situated about 3 km south of the Hellisheidi geothermal power plant. Reykjavik Energy operates the power plant, which currently produces 60,000 tons/year CO2 of magmatic origin. The produced geothermal gas mainly consists of CO2 and H2S. The two gases will be separated in a pilot gas treatment plant, and CO2 will be transported in a pipeline to the injection site. There, CO2 will be fully dissolved in 20 - 25°C water during injection at 25 - 30 bar pressure, resulting in a single fluid phase entering the storage formation, which consists of relatively fresh basaltic lavas. The CO2 charged water is reactive and will dissolve divalent cations from the rock, which will combine with the dissolved carbon to form solid thermodynamically stable carbonate minerals. The injection test is designed to inject 2200 tons of CO2 per year. In the past three years the CarbFix project has been addressing background fluid chemistries at the injection site and characterizing the target reservoir for the planned CO2 injection. Numerous groundwater samples have been collected and analysed. A monitoring and accounting plan has been developed, which integrates surface, subsurface and atmospheric monitoring. A weather station is operating at the injection site for continuous monitoring of atmospheric CO2 and to track all key parameters for the injection. Environmental authorities have granted licenses for the CO2 injection and the use of tracers, based on the monitoring plan. Pipelines, injection and monitoring wells have been installed and equipment test runs are in the final phase. A bailer has been constructed to be used to retrieve samples at reservoir conditions. Hydrological parameters of a three dimensional field model have been calibrated and reactive transport simulations are ongoing. The key risks that the project is currently facing are technical and financial. Until now the project has been facing incidences that have already impacted the time schedule in the CarbFix project. Furthermore the project is facing world-wide exchange rate uncertainty plus the inherited uncertainty that innovative research projects contain. However, the CarbFix group remains optimistic that injection will start in near future.

  3. Preparation and electrical properties of Cr 2O 3 gate insulator embedded with Fe dot

    NASA Astrophysics Data System (ADS)

    Yokota, Takeshi; Kuribayashi, Takaaki; Murata, Shotaro; Gomi, Manabu

    2008-09-01

    We investigated the electrical properties of a metal (Au)/insulator (magneto-electric materials: Cr 2O 3)/magnetic materials (Fe)/tunnel layer (Cr 2O 3)/semiconductor (Si) capacitor. This capacitor shows the typical capacitance-voltage ( C- V) properties of an Si-MIS capacitor with hysteresis depending on the Fe dispersibility which is determined by the deposition condition. The C- V curve of the only sample having a 0.5 nm Fe layer was seen to have a hysteresis window with a clockwise trace, indicating that electrons have been injected into the ultra-thin Fe layer. The samples having Fe layers of other thicknesses show a counterclockwise trace, which indicates that the film has mobile ionic charges due to the dispersed Fe. These results indicated that the charge-injection site, which works as a memory, in the Cr 2O 3 can be prepared by Fe insertion, which is deposited using well-controlled conditions. The results also revealed the possibility of an MIS capacitor containing both ferromagnetic materials and an ME insulating layer in a single system.

  4. Dynamic leaching and fractionation of trace elements from environmental solids exploiting a novel circulating-flow platform.

    PubMed

    Mori, Masanobu; Nakano, Koji; Sasaki, Masaya; Shinozaki, Haruka; Suzuki, Shiho; Okawara, Chitose; Miró, Manuel; Itabashi, Hideyuki

    2016-02-01

    A dynamic flow-through microcolumn extraction system based on extractant re-circulation is herein proposed as a novel analytical approach for simplification of bioaccessibility tests of trace elements in sediments. On-line metal leaching is undertaken in the format of all injection (AI) analysis, which is a sequel of flow injection analysis, but involving extraction under steady-state conditions. The minimum circulation times and flow rates required to determine the maximum bioaccessible pools of target metals (viz., Cu, Zn, Cd, and Pb) from lake and river sediment samples were estimated using Tessier's sequential extraction scheme and an acid single extraction test. The on-line AIA method was successfully validated by mass balance studies of CRM and real sediment samples. Tessier's test in on-line AI format demonstrated to be carried out by one third of extraction time (6h against more than 17 h by the conventional method), with better analytical precision (<9.2% against >15% by the conventional method) and significant decrease in blank readouts as compared with the manual batch counterpart. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. Injection practices in Nepal: health policymakers’ perceptions

    PubMed Central

    2014-01-01

    Background The unnecessary and unsafe use of injections is common in developing countries like Nepal. Policymakers have an important role in promoting rational and safe injection use. Hence, the present study was carried out to explore the perception of health policymakers regarding safe injection practice in Nepal. Methods An exploratory qualitative study design was used in this study. Key policymakers from both the central and regional level were selected using purposive sampling. A semi-structured questionnaire advocated by the World Health Organization (WHO) was used after modifying the context. Interviews were conducted to clarify doubts and obtain additional information. The data was analyzed manually using deductive content analysis technique. Results In total, eleven policymakers participated. All unanimously agreed that injection safety is a problem and seven participants reported that injections are overused. They shared the opinion that injections are administered by various providers, including formal and informal health providers, and also quacks. Almost half the respondents reported that the National Drug Policy discourages injection overuse, while others reported that the policy contains no provisions regarding injection overuse. Most policymakers stated that only single-use disposable injection equipment is used to provide injection, while others thought that sterilizable glass syringe is also used. More than half of the participants believed that the quality of injection equipment available in the Nepalese market is not regulated by any government institution. Almost two-third of the policymakers stated that syringes and needles are not reused, while the rest thought syringes might be reused without sterilization in some parts of the country. Almost half of the respondents stated that illegal commercialization of used syringes exists in Nepal. Almost all respondents thought that health care institutions have a waste management plan, while more than half of them opined that such plans are limited to tertiary care hospitals located in the capital. Conclusions The result of this study revealed a divergence of views among policymakers, even among those in the same ministry. Though there has been some effort from the government to increase the safety of injection practices, greater efforts are required, especially with regard to standardization of policies and procedures related to injection practice. PMID:24957575

  6. Injection practices in Nepal: health policymakers' perceptions.

    PubMed

    Gyawali, Sudesh; Rathore, Devendra Singh; Shankar, Pathiyil Ravi; Maskey, Manisha; Vikash, Kumar K C

    2014-06-24

    The unnecessary and unsafe use of injections is common in developing countries like Nepal. Policymakers have an important role in promoting rational and safe injection use. Hence, the present study was carried out to explore the perception of health policymakers regarding safe injection practice in Nepal. An exploratory qualitative study design was used in this study. Key policymakers from both the central and regional level were selected using purposive sampling. A semi-structured questionnaire advocated by the World Health Organization (WHO) was used after modifying the context. Interviews were conducted to clarify doubts and obtain additional information. The data was analyzed manually using deductive content analysis technique. In total, eleven policymakers participated. All unanimously agreed that injection safety is a problem and seven participants reported that injections are overused. They shared the opinion that injections are administered by various providers, including formal and informal health providers, and also quacks. Almost half the respondents reported that the National Drug Policy discourages injection overuse, while others reported that the policy contains no provisions regarding injection overuse. Most policymakers stated that only single-use disposable injection equipment is used to provide injection, while others thought that sterilizable glass syringe is also used. More than half of the participants believed that the quality of injection equipment available in the Nepalese market is not regulated by any government institution. Almost two-third of the policymakers stated that syringes and needles are not reused, while the rest thought syringes might be reused without sterilization in some parts of the country. Almost half of the respondents stated that illegal commercialization of used syringes exists in Nepal. Almost all respondents thought that health care institutions have a waste management plan, while more than half of them opined that such plans are limited to tertiary care hospitals located in the capital. The result of this study revealed a divergence of views among policymakers, even among those in the same ministry. Though there has been some effort from the government to increase the safety of injection practices, greater efforts are required, especially with regard to standardization of policies and procedures related to injection practice.

  7. [Comparison of basic carboxypeptidases activity in male rats tissues at a single injection of haloperidol].

    PubMed

    Pravosudova, N A; Bykova, I O

    2014-01-01

    The influence of a single injection of haloperidol on basic carboxypeptidases (biologically active peptide processing enzymes) activity in rat tissues was studied. Acute exposure to haloperidol increased the activity of carboxypeptidases H (CP H) in hypothalamic-pituitary-adrenal system and cerebellum and reduced such activity in testes. Multidirectional changes of PMSF-inhibited carboxypeptidases activity (PMSF-CP) were observed after a single haloperidol injection in all studied tissues except testes. It is suggested that changes of CP H and PMSF-CP activity might affect levels of regulatory peptides in the brain and blood and thus may be involved in general and side effects of haloperidol on the organism.

  8. A PIV Study of Slotted Air Injection for Jet Noise Reduction

    NASA Technical Reports Server (NTRS)

    Henderson, Brenda S.; Wernet, Mark P.

    2012-01-01

    Results from acoustic and Particle Image Velocimetry (PIV) measurements are presented for single and dual-stream jets with fluidic injection on the core stream. The fluidic injection nozzles delivered air to the jet through slots on the interior of the nozzle at the nozzle trailing edge. The investigations include subsonic and supersonic jet conditions. Reductions in broadband shock noise and low frequency mixing noise were obtained with the introduction of fluidic injection on single stream jets. Fluidic injection was found to eliminate shock cells, increase jet mixing, and reduce turbulent kinetic energy levels near the end of the potential core. For dual-stream subsonic jets, the introduction of fluidic injection reduced low frequency noise in the peak jet noise direction and enhanced jet mixing. For dual-stream jets with supersonic fan streams and subsonic core streams, the introduction of fluidic injection in the core stream impacted the jet shock cell structure but had little effect on mixing between the core and fan streams.

  9. Turbine vane gas film cooling with injection in the leading edge region from a single row of spanwise angled holes

    NASA Technical Reports Server (NTRS)

    Lecuyer, M. R.; Hanus, G. J.

    1976-01-01

    An experimental study of gas film cooling was conducted on a 3X size model turbine vane. Injection in the leading edge region was from a single row of holes angled in a spanwise direction. Measurements of the local heat flux downstream from the row of coolant holes, both with and without film coolant flow, were used to determine the film cooling performance presented in terms of the Stanton number ratio. Results for a range of coolant blowing ratio, M = 0 to 2.0, indicate a reduction in heat flux of up to 15 to 30 percent at a point 10 to 11 hole diameters downstream from injection. An optimum coolant blowing ratio corresponds to a coolant-to-freestream velocity ratio in the range of 0.5. The shallow injection angle resulted in superior cooling performance for injection closest to stagnation, while the effect of injection angle was insignificant for injection further from stagnation.

  10. Multicategory nets of single-layer perceptrons: complexity and sample-size issues.

    PubMed

    Raudys, Sarunas; Kybartas, Rimantas; Zavadskas, Edmundas Kazimieras

    2010-05-01

    The standard cost function of multicategory single-layer perceptrons (SLPs) does not minimize the classification error rate. In order to reduce classification error, it is necessary to: 1) refuse the traditional cost function, 2) obtain near to optimal pairwise linear classifiers by specially organized SLP training and optimal stopping, and 3) fuse their decisions properly. To obtain better classification in unbalanced training set situations, we introduce the unbalance correcting term. It was found that fusion based on the Kulback-Leibler (K-L) distance and the Wu-Lin-Weng (WLW) method result in approximately the same performance in situations where sample sizes are relatively small. The explanation for this observation is by theoretically known verity that an excessive minimization of inexact criteria becomes harmful at times. Comprehensive comparative investigations of six real-world pattern recognition (PR) problems demonstrated that employment of SLP-based pairwise classifiers is comparable and as often as not outperforming the linear support vector (SV) classifiers in moderate dimensional situations. The colored noise injection used to design pseudovalidation sets proves to be a powerful tool for facilitating finite sample problems in moderate-dimensional PR tasks.

  11. Pharmacokinetics of Short- and Long-acting Formulations of Oxytetracycline After Intramuscular Administration in Chickens.

    PubMed

    Gberindyer, Aondover F; Okpeh, Ene R; Semaka, Asaaga A

    2015-12-01

    Both short- and long-acting formulations of oxytetracycline are commonly used in veterinary medicine to treat animals infected with gram-negative and gram-positive bacteria, rickettsiae, mycoplasma, and chlamydiae. To compare pharmacokinetics of short- and long-acting oxytetracycline in chickens, injectable formulations from the same pharmaceutical company were administered to healthy 6-week-old broiler chickens in accordance to the labeled instructions. Fourteen chickens were separated into 2 groups: chickens in group A (n = 7) were administered the short-acting formulation (10 mg/kg IM q24h) for 4 consecutive days, whereas those in group B (n = 7) were treated with a single dose (20 mg/kg IM) of the long-acting formulation. Blood samples were collected into heparinized tubes before and at 0.25, 0.5, 1, 1.5, 2, 4, 6, 8, 10, and 24 hours after initial treatment. Thereafter, blood samples were taken every 24 hours up to 120 hours. Plasma concentrations of oxytetracycline were determined by competitive enzyme-linked immunoabsorbent assay, and pharmacokinetic parameters were obtained. Both formulations delivered therapeutic plasma concentrations of oxytetracycline for approximately 100% of their respective dosing intervals as recommended. However, considering the additional labor, patient stress, and mortalities associated with handling, in addition to rejection of the carcass due to tissue necrosis resulting from multiple injections, we recommend use of the long-acting instead of the short-acting injectable formulation in broiler chickens.

  12. 21 CFR 522.2483 - Triamcinolone.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL DRUGS..., administer 0.05 to 0.1 mg per pound (/lb) of body weight as a single injection. For dermatologic disorders, administer 0.1 mg per pound (/lb) of body weight as a single injection. If symptoms recur, the dose may be...

  13. 21 CFR 522.2483 - Triamcinolone.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL DRUGS..., administer 0.05 to 0.1 mg per pound (/lb) of body weight as a single injection. For dermatologic disorders, administer 0.1 mg per pound (/lb) of body weight as a single injection. If symptoms recur, the dose may be...

  14. 21 CFR 522.2483 - Triamcinolone.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL DRUGS..., administer 0.05 to 0.1 mg per pound (/lb) of body weight as a single injection. For dermatologic disorders, administer 0.1 mg per pound (/lb) of body weight as a single injection. If symptoms recur, the dose may be...

  15. 21 CFR 522.2483 - Triamcinolone.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL DRUGS..., administer 0.05 to 0.1 mg per pound (/lb) of body weight as a single injection. For dermatologic disorders, administer 0.1 mg per pound (/lb) of body weight as a single injection. If symptoms recur, the dose may be...

  16. 21 CFR 522.2483 - Triamcinolone.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL DRUGS..., administer 0.05 to 0.1 mg per pound (/lb) of body weight as a single injection. For dermatologic disorders, administer 0.1 mg per pound (/lb) of body weight as a single injection. If symptoms recur, the dose may be...

  17. Charge injection and transport in a single organic monolayer island

    NASA Astrophysics Data System (ADS)

    Vuillaume, Dominique

    2005-03-01

    We report how electrons and holes, that are locally injected in a single organic monolayer island (where organic monolayers are made from sublimated oligomers (pentacene and other oligoacenes), or made from chemisorption in solution (self-assembled monolayers) of pi-conjugated moieties), stay localized or are able to delocalize over the island as a function of the molecular conformation (order vs. disorder) of this island. Charge carriers were locally injected by the apex of an atomic force microscope tip, and the resulting two-dimensional distribution and concentration of injected charges were measured by electrical force microscopy (EFM) experiments. We show that in crystalline monolayer islands, both electrons and holes can be equally injected, at a similar charge concentration for symmetric injection bias conditions, and that both charge carriers are delocalized over the whole island. On the contrary, charges injected into a more disordered monolayer stay localized at their injection point. These different results are discussed in relation with the electrical performances of molecular devices made from these monolayers (OFET, SAMFET). These results provide insight into the electronic properties, at the nanometer scale, of these molecular devices.

  18. A prospective, randomized comparison between single- and multiple-injection techniques for ultrasound-guided subgluteal sciatic nerve block.

    PubMed

    Yamamoto, Hiroto; Sakura, Shinichi; Wada, Minori; Shido, Akemi

    2014-12-01

    It is believed that local anesthetic injected to obtain circumferential spread around nerves produces a more rapid onset and successful blockade after some ultrasound-guided peripheral nerve blocks. However, evidence demonstrating this point is limited only to the popliteal sciatic nerve block, which is relatively easy to perform by via a high-frequency linear transducer. In the present study, we tested the hypothesis that multiple injections of local anesthetic to make circumferential spread would improve the rate of sensory and motor blocks compared with a single-injection technique for ultrasound-guided subgluteal sciatic nerve block, which is considered a relatively difficult block conducted with a low-frequency, curved-array transducer. Ninety patients undergoing knee surgery were divided randomly into 2 groups to receive the ultrasound-guided subgluteal approach to sciatic nerve block with 20 mL of 1.5% mepivacaine with epinephrine. For group M (the multiple-injection technique), the local anesthetic was injected to create circumferential spread around the sciatic nerve without limitation on the number of needle passes. For group S (the single-injection technique), the number of needle passes was limited to 1, and the local anesthetic was injected to create spread along the dorsal surface of the sciatic nerve, during which no adjustment of the needle tip was made. Sensory and motor blockade were assessed in double-blind fashion for 30 minutes after completion of the block. The primary outcome was sensory blockade of all sciatic components tested, including tibial, superficial peroneal, and sural nerves at 30 minutes after injection. Data from 86 patients (43 in each group) were analyzed. Block execution took more time for group M than group S. The proportion of patients with complete sensory blockade of all sciatic components at 30 minutes after injection was significantly larger for group M than group S (41.9% vs 16.3%, P = 0.018). Complete motor blockade of foot and toes extension also was observed more frequently in group M than in group S (67.4% vs 34.9%, P = 0.005 and 51.2% vs 25.6%, P = 0.027, respectively). When ultrasound-guided subgluteal sciatic nerve block is conducted, multiple injections of local anesthetic to make a circumferential spread around the sciatic nerve improve the rate of sensory and motor blocks compared with a single injection.

  19. Single-step CE for miniaturized and easy-to-use system.

    PubMed

    Ono, Koichi; Kaneda, Shohei; Fujii, Teruo

    2013-03-01

    We developed a novel single-step capillary electrophoresis (SSCE) scheme for miniaturized and easy to use system by using a microchannel chip, which was made from the hydrophilic material polymethyl methacrylate (PMMA), equipped with a capillary stop valve. Taking the surface tension property of liquids into consideration, the capillary effect was used to introduce liquids and control capillary stop valves in a partial barrier structure in the wall of the microchannel. Through the combined action of stop valves and air vents, both sample plug formation for electrophoresis and sample injection into a separation channel were successfully performed in a single step. To optimize SSCE, different stop valve structures were evaluated using actual microchannel chips and the finite element method with the level set method. A partial barrier structure at the bottom of the channel functioned efficiently as a stop valve. The stability of stop valve was confirmed by a shock test, which was performed by dropping the microchannel chip to a floor. Sample plug deformation could be reduced by minimizing the size of the side partial barrier. By dissolving hydroxyl ethyl cellulose and using it as the sample solution, the EOF and adsorption of the sample into the PMMA microchannel were successfully reduced. Using this method, a 100-bp DNA ladder was concentrated; good separation was observed within 1 min. At a separation length of 5 mm, the signal was approximately 20-fold higher than a signal of original sample solution by field-amplified sample stacking effect. All operations, including liquid introduction and sample separation, can be completed within 2 min by using the SSCE scheme. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Multiplexed Western Blotting Using Microchip Electrophoresis.

    PubMed

    Jin, Shi; Furtaw, Michael D; Chen, Huaxian; Lamb, Don T; Ferguson, Stephen A; Arvin, Natalie E; Dawod, Mohamed; Kennedy, Robert T

    2016-07-05

    Western blotting is a commonly used protein assay that combines the selectivity of electrophoretic separation and immunoassay. The technique is limited by long time, manual operation with mediocre reproducibility, and large sample consumption, typically 10-20 μg per assay. Western blots are also usually used to measure only one protein per assay with an additional housekeeping protein for normalization. Measurement of multiple proteins is possible; however, it requires stripping membranes of antibody and then reprobing with a second antibody. Miniaturized alternatives to Western blot based on microfluidic or capillary electrophoresis have been developed that enable higher-throughput, automation, and greater mass sensitivity. In one approach, proteins are separated by electrophoresis on a microchip that is dragged along a polyvinylidene fluoride membrane so that as proteins exit the chip they are captured on the membrane for immunoassay. In this work, we improve this method to allow multiplexed protein detection. Multiple injections made from the same sample can be deposited in separate tracks so that each is probed with a different antibody. To further enhance multiplexing capability, the electrophoresis channel dimensions were optimized for resolution while keeping separation and blotting times to less than 8 min. Using a 15 μm deep × 50 μm wide × 8.6 cm long channel, it is possible to achieve baseline resolution of proteins that differ by 5% in molecular weight, e.g., ERK1 (44 kDa) from ERK2 (42 kDa). This resolution allows similar proteins detected by cross-reactive antibodies in a single track. We demonstrate detection of 11 proteins from 9 injections from a single Jurkat cell lysate sample consisting of 400 ng of total protein using this procedure. Thus, multiplexed Western blots are possible without cumbersome stripping and reprobing steps.

  1. Imaging Determinants of Clinical Effectiveness of Lumbar Transforaminal Epidural Steroid Injections.

    PubMed

    Maus, Timothy P; El-Yahchouchi, Christine A; Geske, Jennifer R; Carter, Rickey E; Kaufmann, Timothy J; Wald, John T; Diehn, Felix E

    2016-12-01

    To examine associations between imaging characteristics of compressive lesions and patient outcomes after lumbar transforaminal epidural steroid injections (TFESIs) stratified by steroid formulation (solution versus suspension). Retrospective observational study, academic radiology practice. A 516-patient sample was selected from 2,634 consecutive patients receiving lumbar TFESI for radicular pain. The advanced imaging study(s) preceding sampled TFESI were reviewed. Compressive lesions were described by a) nature of the lesion [disc herniation, fixed stenosis, synovial cyst, epidural fibrosis, no lesion] b) degree of neural compression [4 part scale], and c) presence of a tandem lesion. Associations between 2-month categorical outcomes (responder rates for pain, functional recovery) and imaging characteristics, stratified by steroid formulation, were examined with chi-squared tests of categorical outcomes and multivariable logistic regression models. Disc herniation patients had more responders for functional recovery than patients with fixed lesions (54% versus 38%, P = 0.01). Patients with fixed lesions receiving steroid solution (dexamethasone) had more responders for pain relief, with a similar trend for functional recovery, than patients receiving suspensions (59% versus 40%, P = 0.01). Outcomes for patients with fixed lesions treated with dexamethasone were not statistically different from those for disc herniation patients. Patients with single compressive lesions had more responders than those with tandem lesions (55% versus 41%, P = 0.03). In the entire sample, outcomes for disc herniations were more favorable than for fixed lesions. However, fixed lesions treated with dexamethasone had outcomes indistinguishable from disc herniations. Single lesions had better outcomes than tandem lesions. © 2016 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  2. Atypical excretion profile and GC/C/IRMS findings may last for nine months after a single dose of nandrolone decanoate.

    PubMed

    Palonek, Elzbieta; Ericsson, Magnus; Gårevik, Nina; Rane, Anders; Lehtihet, Mikael; Ekström, Lena

    2016-04-01

    The use of the anabolic androgenic steroid nandrolone and its prohormones is prohibited in sport. A common route of nandrolone administration is intramuscular injections of a nandrolone ester. Here we have investigated the detection time of nandrolone and 19-norandrosterone and 19-noretiocholanolone metabolites in eleven healthy men after the administration of a 150 mg dose of nandrolone decanoate. The urinary concentrations of nandrolone and the metabolites were monitored by GC-MS/MS for nine months and in some samples the presence of 19-norandrosterone was confirmed by GC/C/IRMS analysis. The participants were genotyped for polymorphisms in PDE7B1 and UGT2B15 genes previously shown to influence the activation and inactivation of nandrolone decanoate. There were large inter-individual variations in the excretion rate of nandrolone and the metabolites, although not related to genetic variations in the UGT2B15 (rs1902023) and PDE7B1 (rs7774640) genes. After the administration, 19-norandrosterone was found at 2-8-fold higher concentrations than 19-noretiocholanolone. We showed that nandrolone doping can be identified 4 and 9 months after the injection of only one single dose in six and three individuals, respectively. We also noted that GC/C/IRMS confirms the presence of exogenous 19-norandrosterone in the urine samples, showing δ13 values around -32 ‰. This was true even in a sample that was not identified as an atypical finding after the GC-MS/MS analysis further showing the power of using GC/C/IRMS in routine anti-doping settings. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Comprehensive analysis of pharmaceutical products using simultaneous mixed-mode (ion-exchange/reversed-phase) and hydrophilic interaction liquid chromatography.

    PubMed

    Kazarian, Artaches A; Nesterenko, Pavel N; Soisungnoen, Phimpha; Burakham, Rodjana; Srijaranai, Supalax; Paull, Brett

    2014-08-01

    Liquid chromatographic assays were developed using a mixed-mode column coupled in sequence with a hydrophilic interaction liquid chromatography column to allow the simultaneous comprehensive analysis of inorganic/organic anions and cations, active pharmaceutical ingredients, and excipients (carbohydrates). The approach utilized dual sample injection and valve-mediated column switching and was based upon a single high-performance liquid chromatography gradient pump. The separation consisted of three distinct sequential separation mechanisms, namely, (i) ion-exchange, (ii) mixed-mode interactions under an applied dual gradient (reversed-phase/ion-exchange), and (iii) hydrophilic interaction chromatography. Upon first injection, the Scherzo SS C18 column (Imtakt) provided resolution of inorganic anions and cations under isocratic conditions, followed by a dual organic/salt gradient to elute active pharmaceutical ingredients and their respective organic counterions and potential degradants. At the top of the mixed-mode gradient (high acetonitrile content), the mobile phase flow was switched to a preconditioned hydrophilic interaction liquid chromatography column, and the standard/sample was reinjected for the separation of hydrophilic carbohydrates, some of which are commonly known excipients in drug formulations. The approach afforded reproducible separation and resolution of up to 23 chemically diverse solutes in a single run. The method was applied to investigate the composition of commercial cough syrups (Robitussin®), allowing resolution and determination of inorganic ions, active pharmaceutical ingredients, excipients, and numerous well-resolved unknown peaks. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Sustained Neuroprotection From a Single Intravitreal Injection of PGJ2 in a Nonhuman Primate Model of Nonarteritic Anterior Ischemic Optic Neuropathy

    PubMed Central

    Miller, Neil R.; Johnson, Mary A.; Nolan, Theresa; Guo, Yan; Bernstein, Alexander M.; Bernstein, Steven L.

    2014-01-01

    Purpose. Prostaglandin J2 (PGJ2) is neuroprotective in a murine model of nonarteritic anterior ischemic optic neuropathy (NAION). After assessing for potential toxicity, we evaluated the efficacy of a single intravitreal (IVT) injection of PGJ2 in a nonhuman primate model of NAION (pNAION). Methods. We assessed PGJ2 toxicity by administering it as a single high-dose intravenous (IV) injection, consecutive daily high-dose IV injections, or a single IVT injection in one eye of five adult rhesus monkeys. To assess efficacy, we induced pNAION in one eye of five adult male rhesus monkeys using a laser-activated rose bengal induction method. We then injected the eye with either PGJ2 or phosphate-buffered saline (PBS) intravitreally immediately or 5 hours post induction. We performed a clinical assessment, optical coherence tomography, electrophysiological testing, fundus photography, and fluorescein angiography in all animals prior to induction and at 1 day, 1 week, 2 weeks, and 4 weeks after induction. Following analysis of the first eye, we induced pNAION in the contralateral eye and then injected either PGJ2 or PBS. We euthanized all animals 5 weeks after final assessment of the fellow eye and performed both immunohistochemical and light and electron microscopic analyses of the retina and optic nerves. Results. Toxicity: PGJ2 caused no permanent systemic toxicity regardless of the amount injected or route of delivery, and there was no evidence of any ocular toxicity with the dose of PGJ2 used in efficacy studies. Transient reduction in the amplitudes of the visual evoked potentials and the N95 component of the pattern electroretinogram (PERG) occurred after both IV and IVT administration of high doses of PGJ2; however, the amplitudes returned to normal in all animals within 1 week. Efficacy: In all eyes, a single IVT dose of PGJ2 administered immediately or shortly after induction of pNAION resulted in a significant reduction of clinical, electrophysiological, and histological damage compared with vehicle-injected eyes (P = 0.03 for both VEP and PERG; P = 0.05 for axon counts). Conclusions. In nonhuman primates, PGJ2 administered either intravenously or intravitreally produces no permanent toxicity at even four times the dose given for neuroprotection. Additionally, a single IVT dose of PGJ2 is neuroprotective when administered up to 5 hours after induction of pNAION. PMID:25298416

  5. Efficacy and safety of single injection of cross-linked sodium hyaluronate vs. three injections of high molecular weight sodium hyaluronate for osteoarthritis of the knee: a double-blind, randomized, multi-center, non-inferiority study.

    PubMed

    Ha, Chul-Won; Park, Yong-Beom; Choi, Chong-Hyuk; Kyung, Hee-Soo; Lee, Ju-Hong; Yoo, Jae Doo; Yoo, Ju-Hyung; Choi, Choong-Hyeok; Kim, Chang-Wan; Kim, Hee-Chun; Oh, Kwang-Jun; Bin, Seong-Il; Lee, Myung Chul

    2017-05-26

    This randomized, double-blind, multi-center, non-inferiority trial was conducted to assess the efficacy and safety of a cross-linked hyaluronate (XLHA, single injection form) compared with a linear high molecular hyaluronate (HMWHA, thrice injection form) in patients with symptomatic knee osteoarthritis. Two hundred eighty seven patients with osteoarthritis (Kellgren-Lawrence grade I to III) were randomized to each group. Three weekly injections were given in both groups but two times of saline injections preceded XLHA injection to maintain double-blindness. Primary endpoint was the change of weight-bearing pain (WBP) at 12 weeks after the last injection. Secondary endpoints included Western Ontario and McMaster Universities Osteoarthritis index; patient's and investigator's global assessment; pain at rest, at night, or in motion; OMERACT-OARSI responder rate; proportion of patients achieving at least 20 mm or 40% decrease in WBP; and rate of rescue medicine use and its total consumption. Mean changes of WBP at 12 weeks after the last injection were -33.3 mm with XLHA and -29.2 mm with HMWHA, proving non-inferiority of XLHA to HMWHA as the lower bound of 95% CI (-1.9 mm, 10.1 mm) was well above the predefined margin (-10 mm). There were no significant between-group differences in all secondary endpoints. Injection site pain was the most common adverse event and no remarkable safety issue was identified. This study demonstrated that a single injection of XLHA was non-inferior to three weekly injections of HMWHA in terms of WBP reduction, and supports XLHA as an effective and safe treatment for knee osteoarthritis. ClinicalTrials.gov ( NCT01510535 ). This trial was registered on January 6, 2012.

  6. Single-use autoinjector for once-weekly intramuscular injection of IFNβ-1a.

    PubMed

    Limmroth, Volker; Gerbershagen, Kathrin

    2014-12-01

    IFNβ products and glatiramer acetate are established treatment first-line options in long-term disease-modifying therapy of multiple sclerosis (MS). These self-injectable medications are used once weekly to once daily. Injection-related issues are common patient-cited reasons for nonadherence. Autoinjectors have been shown to support long-term adherence to injectable medications. The ability to self-inject in MS patients has been associated with a reduced risk of missed injections and drug discontinuation, and a beneficial effect on patient independence. The recently introduced easy-to-use prefilled once-weekly pen is a safe and effective device for intramuscular (IM) IFNβ-1a application and provides a convenient method for self-injection. We reviewed the available published evidence on the characteristics of this device. The once-weekly pen facilitates self-injection and was preferred over prefilled syringes by patients in a prospective open-label, multicenter Phase IIIb trial in MS patients who had been using IM IFNβ-1a in prefilled syringes. The simple and safe handling, shielded short needle, single-use disposable design and virtually painless injection by the device may contribute to adherence, quality of life and independence in patients using IM IFNβ-1a.

  7. Sequential determination of multi-nutrient elements in natural water samples with a reverse flow injection system.

    PubMed

    Lin, Kunning; Ma, Jian; Yuan, Dongxing; Feng, Sichao; Su, Haitao; Huang, Yongming; Shangguan, Qipei

    2017-05-15

    An integrated system was developed for automatic and sequential determination of NO 2 - , NO 3 - , PO 4 3- , Fe 2+ , Fe 3+ and Mn 2+ in natural waters based on reverse flow injection analysis combined with spectrophotometric detection. The system operation was controlled by a single chip microcomputer and laboratory-programmed software written in LabVIEW. The experimental parameters for each nutrient element analysis were optimized based on a univariate experimental design, and interferences from common ions were evaluated. The upper limits of the linear range (along with detection limit, µmolL -1 ) of the proposed method was 20 (0.03), 200 (0.7), 12 (0.3), 5 (0.03), 5 (0.03), 9 (0.2) µmolL -1 , for NO 2 - , NO 3 - , PO 4 3- , Fe 2+ , Fe 3+ and Mn 2+ , respectively. The relative standard deviations were below 5% (n=9-13) and the recoveries varied from 88.0±1.0% to 104.5±1.0% for spiked water samples. The sample throughput was about 20h -1 . This system has been successfully applied for the determination of multi-nutrient elements in different kinds of water samples and showed good agreement with reference methods (slope 1.0260±0.0043, R 2 =0.9991, n=50). Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Influence of diazepam on blood glucose levels in nondiabetic and non-insulin-dependent diabetic subjects under dental treatment with local anesthesia.

    PubMed Central

    Schaira, Vanessa Rocha Lima; Ranali, José; Saad, Mário José Abdalla; de Oliveira, Patrícia Cristine; Ambrosano, Glaúcia Maria Bovi; Volpato, Maria Cristina

    2004-01-01

    The effect of diazepam on blood glucose concentration (BGC) was investigated in a double-blind cross-over study in 10 healthy and 10 non-insulin-dependent diabetic subjects taking oral hypoglycemic drugs. In the first session, fasting blood samples were taken for blood glucose and glycosylated hemoglobin estimation and at 60, 80, 95, 125, and 155 minutes thereafter for glucose estimation. In another 2 sessions, a venous sample was taken immediately before premedication (5 mg diazepam or placebo randomly given during breakfast). One hour later a blood sample was taken, and the volunteers were submitted to periodontal treatment after injection of 1.8 mL of 2% mepivacaine with 1:100,000 adrenaline. Venous blood samples were taken at 15, 30, 60, and 90 minutes after injection. The changes in BGC were analyzed using analysis of variance (ANOVA) for repeated measures; the means were compared using Tukey test (P = .05). Statistically significant differences in the BGC were observed between diabetic and nondiabetic groups (P = .00003). However, there were no significant differences among the sessions of the same group (P = .29). The results of this study show that a single dose of 5 mg diazepam before dental treatment does not influence BGC in nondiabetic and non-insulin-dependent diabetic subjects. PMID:15106685

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zelenyuk, Alla; Reitz, Paul; Stewart, Mark L.

    Gasoline Compression Ignition (GCI) engines have the potential to achieve high fuel efficiency and to significantly reduce both NOx and particulate matter (PM) emissions by operating under dilute partially-premixed conditions. This low temperature combustion strategy is dependent upon direct-injection of gasoline during the compression stroke and potentially near top dead center (TDC). The timing and duration of the in-cylinder injections can be tailored based on speed and load to create optimized conditions that result in a stable combustion. We present the results of advanced aerosol analysis methods that have been used for detailed real-time characterization of PM emitted from amore » single-cylinder GCI engine operated at different speed, load, timing, and number and duration of near-TDC fuel injections. PM characterization included 28 measurements of size and composition of individual particles sampled directly from the exhaust and after mass and/or mobility classification. We use these data to calculate particle effective density, fractal dimension, dynamic shape factors in free-molecular and transition flow regimes, average diameter of primary spherules, number of spherules, and void fraction of soot agglomerates.« less

  10. Spray flow structure from twin-hole diesel injector nozzles

    DOE PAGES

    Nguyen, D.; Duke, D.; Kastengren, A.; ...

    2017-04-18

    Two techniques were used to study non-evaporating diesel sprays from common rail injectors which were equipped with twin-hole and single-hole nozzles for comparison. To characterise the sprays, high speed optical imaging and x-ray radiography were used. The former was performed at the LTRAC laboratory at Monash University, while the latter was performed at the 7-BM beamline of the Advanced Photon Source at Argonne National Laboratory. The optical imaging made use of high temporal, high spatial resolution spray recordings on a digital camera from which peripheral parameters in the initial injection phase were investigated based on edge detection. The x-ray radiographymore » was used to explore quantitative mass distributions, which were measured on a point-wise basis at roughly similar sampling rate. Three twin-hole nozzles of different subtended angles and a single-hole nozzle were investigated at injection pressure of 1000 bar in environments of 20 bar back pressure. Evidence of strong cavitation was found for all nozzles examined with their C D ranging from 0.62 to 0.69. Penetration of the twin-hole nozzles was found to lag the single-hole nozzle, even before the sprays merged. Finally, switching in hole dominance was observed from one twin-hole nozzle, and this was accompanied by greater instability in mass flow during the transient opening phase of the injector.« less

  11. Spray flow structure from twin-hole diesel injector nozzles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nguyen, D.; Duke, D.; Kastengren, A.

    Two techniques were used to study non-evaporating diesel sprays from common rail injectors which were equipped with twin-hole and single-hole nozzles for comparison. To characterise the sprays, high speed optical imaging and x-ray radiography were used. The former was performed at the LTRAC laboratory at Monash University, while the latter was performed at the 7-BM beamline of the Advanced Photon Source at Argonne National Laboratory. The optical imaging made use of high temporal, high spatial resolution spray recordings on a digital camera from which peripheral parameters in the initial injection phase were investigated based on edge detection. The x-ray radiographymore » was used to explore quantitative mass distributions, which were measured on a point-wise basis at roughly similar sampling rate. Three twin-hole nozzles of different subtended angles and a single-hole nozzle were investigated at injection pressure of 1000 bar in environments of 20 bar back pressure. Evidence of strong cavitation was found for all nozzles examined with their C D ranging from 0.62 to 0.69. Penetration of the twin-hole nozzles was found to lag the single-hole nozzle, even before the sprays merged. Finally, switching in hole dominance was observed from one twin-hole nozzle, and this was accompanied by greater instability in mass flow during the transient opening phase of the injector.« less

  12. Characterization of a high-pressure diesel fuel injection system as a control technology option to improve engine performance and reduce exhaust emissions

    NASA Technical Reports Server (NTRS)

    Mcfadden, J. J.; Dezelick, R. A.; Barrows, R. R.

    1983-01-01

    Test results from a high pressure electronically controlled fuel injection system are compared with a commercial mechanical injection system on a single cylinder, diesel test engine using an inlet boost pressure of 2.6:1. The electronic fuel injection system achieved high pressure by means of a fluid intensifier with peak injection pressures of 47 to 69 MPa. Reduced exhaust emissions were demonstrated with an increasing rate of injection followed by a fast cutoff of injection. The reduction in emissions is more responsive to the rate of injection and injection timing than to high peak injection pressure.

  13. Simultaneous analysis of seven oligopeptides in microbial fuel cell by micro-fluidic chip with reflux injection mode.

    PubMed

    Wang, Wei; Wang, Zijian; Lin, Xiuli; Wang, ZongWen; Fu, FengFu

    2012-10-15

    In this work, a reflux injection mode for the cross form micro-fluidic chip was studied. This injection mode could flexibly control the length of sample plug from less than one channel width (<83 μm) to tens of channel widths (millimeter-sized) by adjusting the injection time. Namely, the separation resolution or sample detection sensitivity could be selectively improved by changing injection time. Composed of four steps, the reflux injection mode alleviated the electrophoretic sampling bias and prevented sample leakage successfully. On a micro-fluidic chip coupled with laser induced fluorescence (LIF) detector, the injection mode was applied to separate seven oligopeptides, namely GG, GL, RPP, KPV, VKK, WYD and YWS. All analytes were completely separated and detected within 12 min with detection limits of 25-625 nmol/L. At last, the proposed method had been successfully applied to detect oligopeptides consumed by bacillus licheniformis in anode chamber of microbial fuel cell (MFC) to study the effect of oligopeptides on the MFC running. Copyright © 2012 Elsevier B.V. All rights reserved.

  14. Synchronization of skin ablation and microjet injection for an effective transdermal drug delivery

    NASA Astrophysics Data System (ADS)

    Jang, Hun-jae; Yeo, Seonggu; Yoh, Jack J.

    2016-04-01

    An Er:YAG laser with 2940-nm wavelength and 150-µs pulse duration was built for the purpose of combined ablation and microjet injection. A shorter pulse duration compared to common erbium lasers in dentistry is desirable for a synchronization of skin ablation and subsequent microjet injection into target skin for transdermal injection of liquid dose. A single laser beam is split into two for an optimal energy of pre-ablation of skin and the residual energy allocated to a microjet ejection. A newly designed injector consists of an L-shaped chamber and a parabolic mirror in a single unit, and the handheld laser is a part of an integrated system requiring no optical fiber. Through various injection tests using the porcine skin, the effectiveness of the new delivery system is herein evaluated.

  15. Prospective Observational Evaluation of Time-Dependency of Adalimumab Immunogenicity and Drug Concentrations: The Poetic Study.

    PubMed

    Ungar, Bella; Engel, Tal; Yablecovitch, Doron; Lahat, Adi; Lang, Alon; Avidan, Benjamin; Har-Noy, Ofir; Carter, Dan; Levhar, Nina; Selinger, Limor; Neuman, Sandra; Natour, Ola Haj; Yavzori, Miri; Fudim, Ella; Picard, Orit; Kopylov, Uri; Chowers, Yehuda; Naftali, Timna; Broide, Efrat; Shachar, Eyal; Eliakim, Rami; Ben-Horin, Shomron

    2018-06-01

    Adalimumab is usually self-injected at home, making prospective serial-sampling studies challenging and scarce. This has led to a gap in knowledge about evolution of anti-adalimumab antibodies (AAAs) over time and its correlation with clinical and inflammatory outcomes. A program for home visits by physicians at induction, every 3 months and at event of relapse, was established prospectively for Crohn's disease (CD) patients. At each visit, patients' clinical scores were determined and sera were obtained for C-reactive protein, drug, and AAA levels. This cohort was compared to a parallel prospective cohort of infliximab-treated CD patients. In a subgroup of 29 patients, trough and in-between-trough levels were compared, to elucidate the importance of timing of sampling during the injection cycle. Ninety-eight CD patients starting adalimumab were prospectively followed (median follow-up 44 weeks) and 621 serum samples were analyzed. Thirty-three patients (32%) developed AAA; 18/33 (55%) of them as early as week 2, and 26/33 (79%) by week 14. Induction period AAAs were strongly associated with primary non-response (odds ratio (OR) = 5.4, 95% confidence interval (CI): 1.6-17.8, p = 0.005). As compared to antibodies-to-infliximab (ATI), AAA formation rate over time was significantly lower (p = 0.01) and AAA were much more specific-85% of AAA events were associated with loss-of-response compared with 58% rate for ATI (p = 0.01). In 29 patients sampled serially during an injection cycle, levels of drug and AAA seemed comparable between four time-points during a single cycle both in patients with or without AAA (n = 8, n = 21, respectively). When followed prospectively and serially, AAAs are found to arise earlier than previously appreciated and their impact may be more pronounced for primary rather than secondary, non-response. Drug and AAA levels were similar both at trough and in-between injections, enabling to simplify therapeutic drug monitoring of adalimumab.

  16. Study on the characteristic and application of DFB semiconductor lasers under optical injection for microwave photonics

    NASA Astrophysics Data System (ADS)

    Pu, Tao; Wang, Wei wei

    2018-01-01

    In order to apply optical injection effect in Microwave Photonics system, The red-shift effect of the cavity mode of the DFB semiconductor laser under single-frequency optical injection is studied experimentally, and the red-shift curve of the cavity mode is measured. The wavelength-selective amplification property of the DFB semiconductor laser under multi-frequency optical injection is also investigated, and the gain curves for the injected signals in different injection ratios are measured in the experiment. A novel and simple structure to implement a single-passband MPF with wideband tunability based on the wavelength-selective amplification of a DFB semiconductor laser under optical injection is proposed and experimentally demonstrated. MPFs with center frequency tuned from 13 to 41 GHz are realized in the experiment. A wideband and frequency-tunable optoelectronic oscillator based on a directly modulated distributed feedback (DFB) semiconductor laser under optical injection is proposed and experimentally demonstrated. By optical injection, the relaxation oscillation frequency of the DFB laser is enhanced and its high modulation efficiency makes the loop oscillate without the necessary of the electrical filter. An experiment is performed; microwave signals with frequency tuned from 5.98 to 15.22 GHz are generated by adjusting the injection ratio and frequency detuning between the master and slave lasers.

  17. Influence of high-conductivity buffer composition on field-enhanced sample injection coupled to sweeping in CE.

    PubMed

    Anres, Philippe; Delaunay, Nathalie; Vial, Jérôme; Thormann, Wolfgang; Gareil, Pierre

    2013-02-01

    The aim of this work was to clarify the mechanism taking place in field-enhanced sample injection coupled to sweeping and micellar EKC (FESI-Sweep-MEKC), with the utilization of two acidic high-conductivity buffers (HCBs), phosphoric acid or sodium phosphate buffer, in view of maximizing sensitivity enhancements. Using cationic model compounds in acidic media, a chemometric approach and simulations with SIMUL5 were implemented. Experimental design first enabled to identify the significant factors and their potential interactions. Simulation demonstrates the formation of moving boundaries during sample injection, which originate at the initial sample/HCB and HCB/buffer discontinuities and gradually change the compositions of HCB and BGE. With sodium phosphate buffer, the HCB conductivity increased during the injection, leading to a more efficient preconcentration by staking (about 1.6 times) than with phosphoric acid alone, for which conductivity decreased during injection. For the same injection time at constant voltage, however, a lower amount of analytes was injected with sodium phosphate buffer than with phosphoric acid. Consequently sensitivity enhancements were lower for the whole FESI-Sweep-MEKC process. This is why, in order to maximize sensitivity enhancements, it is proposed to work with sodium phosphate buffer as HCB and to use constant current during sample injection. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Automation and integration of multiplexed on-line sample preparation with capillary electrophoresis for DNA sequencing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tan, H.

    1999-03-31

    The purpose of this research is to develop a multiplexed sample processing system in conjunction with multiplexed capillary electrophoresis for high-throughput DNA sequencing. The concept from DNA template to called bases was first demonstrated with a manually operated single capillary system. Later, an automated microfluidic system with 8 channels based on the same principle was successfully constructed. The instrument automatically processes 8 templates through reaction, purification, denaturation, pre-concentration, injection, separation and detection in a parallel fashion. A multiplexed freeze/thaw switching principle and a distribution network were implemented to manage flow direction and sample transportation. Dye-labeled terminator cycle-sequencing reactions are performedmore » in an 8-capillary array in a hot air thermal cycler. Subsequently, the sequencing ladders are directly loaded into a corresponding size-exclusion chromatographic column operated at {approximately} 60 C for purification. On-line denaturation and stacking injection for capillary electrophoresis is simultaneously accomplished at a cross assembly set at {approximately} 70 C. Not only the separation capillary array but also the reaction capillary array and purification columns can be regenerated after every run. DNA sequencing data from this system allow base calling up to 460 bases with accuracy of 98%.« less

  19. Injection-seeded operation of a Q-switched Cr,Tm,Ho:YAG laser

    NASA Technical Reports Server (NTRS)

    Henderson, Sammy W.; Hale, Charley P.; Magee, James R.

    1991-01-01

    Single-frequency Tm,Ho:YAG lasers operating near 2 microns are attractive sources for several applications including eye-safe laser radar (lidar) and pumping of AgGaSe2 parametric oscillators for efficient generation of longer wavelengths. As part of a program to develop a coherent lidar system using Tm,Ho:YAG lasers, a diode laser-pumped tunable CW single-longitudinal-mode (SLM) Cr:Tm:Ho:YAG laser and a flashlamp-pumped single-transverse-mode Q-switched Cr,Tm,Ho:YAG laser were developed. The CW laser was used to injection-seed the flashlamp-pumped laser, resulting in SLM Q-switched output. Operational characteristics of the CW and Q-switched lasers and injection-seeding results are reported.

  20. Analysis for predicting adiabatic wall temperatures with single hole coolant injection into a low speed crossflow

    NASA Astrophysics Data System (ADS)

    Wang, C. R.; Papell, S. S.; Graham, R. W.

    Assuming the local adiabatic wall temperature equals the local total temperature in a low speed coolant mixing layer, integral conservation equations with and without the boundary layer effects are formulated for the mixing layer downstream of a single coolant injection hole oriented at a 30 degree angle to the crossflow. These equations are solved numerically to determine the center line local adiabatic wall temperature and the effective coolant coverage area. Comparison of the numerical results with an existing film cooling experiment indicates that the present analysis permits a simplified but reasonably accurate prediction of the centerline effectiveness and coolant coverage area downstream of a single hole crossflow streamwise injection at 30 degree inclination angle.

  1. Analysis for predicting adiabatic wall temperatures with single hole coolant injection into a low speed crossflow

    NASA Technical Reports Server (NTRS)

    Wang, C. R.; Papell, S. S.; Graham, R. W.

    1981-01-01

    Assuming the local adiabatic wall temperature equals the local total temperature in a low speed coolant mixing layer, integral conservation equations with and without the boundary layer effects are formulated for the mixing layer downstream of a single coolant injection hole oriented at a 30 degree angle to the crossflow. These equations are solved numerically to determine the center line local adiabatic wall temperature and the effective coolant coverage area. Comparison of the numerical results with an existing film cooling experiment indicates that the present analysis permits a simplified but reasonably accurate prediction of the centerline effectiveness and coolant coverage area downstream of a single hole crossflow streamwise injection at 30 degree inclination angle.

  2. Analysis for predicting adiabatic wall temperatures with single hole coolant injection into a low speed crossflow

    NASA Astrophysics Data System (ADS)

    Wang, C. R.; Papell, S. S.; Graham, R. W.

    1981-03-01

    Assuming the local adiabatic wall temperature equals the local total temperature in a low speed coolant mixing layer, integral conservation equations with and without the boundary layer effects are formulated for the mixing layer downstream of a single coolant injection hole oriented at a 30 degree angle to the crossflow. These equations are solved numerically to determine the center-line local adiabatic wall temperature and the effective coolant coverage area. Comparison of the numerical results with an existing film cooling experiment indicates that the present analysis permits a simplified but reasonably accurate prediction of the centerline effectiveness and coolant coverage area downstream of a single hole crossflow streamwise injection at 30-deg inclination angle.

  3. Analysis for predicting adiabatic wall temperatures with single hole coolant injection into a low speed crossflow

    NASA Technical Reports Server (NTRS)

    Wang, C. R.; Papell, S. S.; Graham, R. W.

    1981-01-01

    Assuming the local adiabatic wall temperature equals the local total temperature in a low speed coolant mixing layer, integral conservation equations with and without the boundary layer effects are formulated for the mixing layer downstream of a single coolant injection hole oriented at a 30 degree angle to the crossflow. These equations are solved numerically to determine the center-line local adiabatic wall temperature and the effective coolant coverage area. Comparison of the numerical results with an existing film cooling experiment indicates that the present analysis permits a simplified but reasonably accurate prediction of the centerline effectiveness and coolant coverage area downstream of a single hole crossflow streamwise injection at 30-deg inclination angle.

  4. Successful treatment of unicameral bone cyst by single percutaneous injection of alpha-BSM.

    PubMed

    Thawrani, Dinesh; Thai, Chia Che; Welch, Robert D; Copley, Lawson; Johnston, Charles E

    2009-01-01

    Unicameral bone cyst (UBC) is a benign bone lesion, recognized for its high rate of recurrence and need for repeat procedures to achieve healing. We hypothesized that the osteoconductive material apatitic calcium phosphate (alpha-BSM) could be effective in filling and stimulating resolution of UBC. The purpose of this study was to evaluate clinical and radiographic outcomes of UBC treated by a single injection of alpha-BSM. Thirteen patients (6 male, 7 female) with a mean age of 10.5 years, underwent single percutaneous injection of alpha-BSM for presumed UBC. The aspiration of the cysts was followed by vigorous saline lavage using 2 wide bore needles to disrupt the cyst walls. alpha-BSM "paste" was then injected under fluoroscopic guidance. Radiographs were digitized to measure cystic area (millimeter squares) on 2 orthogonal views. Healing was rated according to a modified Neer outcome grading system. Nine of the 13 patients had had pathologic fractures in the past. Eleven of the 13 patients had had past unsuccessful treatment: multiple steroid injections in 6, curettage and bone grafting in 3, and bone marrow and demineralized bone matrix (Grafton) injection in 2. Five cysts were grade 1 (healed 100%), 6 grade 2 (healed >50%), 2 grade 3 (healed <50% with increased cortical thickness), and none grade 4 (recurrence/enlargement). The average resolution of cystic area in 11/13 cysts was 85.7% at final follow-up of 35.8 months (P=0.0001) with 2.8 mm of average gain in cortical thickness (P=0.0018). None of the 13 lesions required an additional procedure or repeat injection. All patients were clinically asymptomatic at latest follow-up. This is the first study quantifying cyst resolution objectively according to actual decrease in area (millimeter squares). A single injection of alpha-BSM is a safe, minimally invasive and efficacious method to treat UBC in the pediatric population.

  5. In-plane nuclear field formation investigated in single self-assembled quantum dots

    NASA Astrophysics Data System (ADS)

    Yamamoto, S.; Matsusaki, R.; Kaji, R.; Adachi, S.

    2018-02-01

    We studied the formation mechanism of the in-plane nuclear field in single self-assembled In0.75Al0.25As /Al0.3Ga0.7As quantum dots. The Hanle curves with an anomalously large width and hysteretic behavior at the critical transverse magnetic field were observed in many single quantum dots grown in the same sample. In order to explain the anomalies in the Hanle curve indicating the formation of a large nuclear field perpendicular to the photo-injected electron spin polarization, we propose a new model based on the current phenomenological model for dynamic nuclear spin polarization. The model includes the effects of the nuclear quadrupole interaction and the sign inversion between in-plane and out-of-plane components of nuclear g factors, and the model calculations reproduce successfully the characteristics of the observed anomalies in the Hanle curves.

  6. Intralesional Pentamidine: A Novel Therapy for Single Lesions of Bolivian Cutaneous Leishmaniasis.

    PubMed

    Soto, Jaime; Paz, David; Rivero, Daniela; Soto, Paula; Quispe, Jorge; Toledo, Julia; Berman, Jonathan

    2016-04-01

    A novel therapy, intralesional (IL) pentamidine, was compared to intralesional therapy with antimony (ILSb), a World Health Organization-recommended therapy, for single Bolivian Leishmania braziliensis lesions. In Study 1, 90 patients were randomized equally between three injections of ILSb over 5 days, five injections of ILSb over 11 days, and three injections of IL pentamidine (120 μg/mm(2)lesion area [ILPenta-120-3]) over 5 days. Cure rates at 6 months were 57% for ILSb-3 injections, 73% for ILSb-5 injections, and 72% for ILPenta-120-3 injections. Adverse effects were local irritation and injection-site pain-ILSb (60 patients): mild (25), moderate (4); IL pentamidine (30 patients): mild (4), moderate (3). In Study 2, 60 patients were randomized equally between five injections of ILSb and three injections of a double dose of IL pentamidine (240 μg/mm(2)[ILPenta-240-3]). In Study 2, cure rates were 67% for ILSb-5 injections and 73% for ILPenta-240-3. For three IL injections of pentamidine, efficacy was optimized at a dose of 120 μg/mm(2)lesion area. The cure rate of that regimen was similar to that for ILSb-5 injections and nonstatistically larger than that of ILSb-3 injections. IL pentamidine is an attractive alternative to ILSb on the basis of efficacy for Bolivian L. braziliensis, the threat of Sb-resistant parasites, tolerance, and patient convenience of three visits over 5 days. © The American Society of Tropical Medicine and Hygiene.

  7. Joint Cross Well and Single Well Seismic Studies at Lost Hills, California

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gritto, Roland; Daley, Thomas M.; Myer, Larry R.

    2002-06-25

    A series of time-lapse seismic cross well and single well experiments were conducted in a diatomite reservoir to monitor the injection of CO{sub 2} into a hydrofracture zone, based on P- and S-wave data. A high-frequency piezo-electric P-wave source and an orbital-vibrator S-wave source were used to generate waves that were recorded by hydrophones as well as three-component geophones. The injection well was located about 12 m from the source well. During the pre-injection phase water was injected into the hydrofrac-zone. The set of seismic experiments was repeated after a time interval of 7 months during which CO{sub 2} wasmore » injected into the hydrofractured zone. The questions to be answered ranged from the detectability of the geologic structure in the diatomic reservoir to the detectability of CO{sub 2} within the hydrofracture. Furthermore it was intended to determine which experiment (cross well or single well) is best suited to resolve these features. During the pre-injection experiment, the P-wave velocities exhibited relatively low values between 1700-1900 m/s, which decreased to 1600-1800 m/s during the post-injection phase (-5%). The analysis of the pre-injection S-wave data revealed slow S-wave velocities between 600-800 m/s, while the post-injection data revealed velocities between 500-700 m/s (-6%). These velocity estimates produced high Poisson ratios between 0.36 and 0.46 for this highly porous ({approx} 50%) material. Differencing post- and pre-injection data revealed an increase in Poisson ratio of up to 5%. Both, velocity and Poisson estimates indicate the dissolution of CO{sub 2} in the liquid phase of the reservoir accompanied by a pore-pressure increase. The single well data supported the findings of the cross well experiments. P- and S-wave velocities as well as Poisson ratios were comparable to the estimates of the cross well data. The cross well experiment did not detect the presence of the hydrofracture but appeared to be sensitive to overall changes in the reservoir and possibly the presence of a fault. In contrast, the single well reflection data revealed an arrival that could indicate the presence of the hydrofracture between the source and receiver wells, while it did not detect the presence of the fault, possibly due to out of plane reflections.« less

  8. Planar near-nozzle velocity measurements during a single high-pressure fuel injection

    NASA Astrophysics Data System (ADS)

    Schlüßler, Raimund; Gürtler, Johannes; Czarske, Jürgen; Fischer, Andreas

    2015-09-01

    In order to reduce the fuel consumption and exhaust emissions of modern Diesel engines, the high-pressure fuel injections have to be optimized. This requires continuous, time-resolved measurements of the fuel velocity distribution during multiple complete injection cycles, which can provide a deeper understanding of the injection process. However, fuel velocity measurements at high-pressure injection nozzles are a challenging task due to the high velocities of up to 300 m/s, the short injection durations in the range and the high fuel droplet density especially near the nozzle exit. In order to solve these challenges, a fast imaging Doppler global velocimeter with laser frequency modulation (2D-FM-DGV) incorporating a high-speed camera is presented. As a result, continuous planar velocity field measurements are performed with a measurement rate of 200 kHz in the near-nozzle region of a high-pressure Diesel injection. The injection system is operated under atmospheric surrounding conditions with injection pressures up to 1400 bar thereby reaching fuel velocities up to 380 m/s. The measurements over multiple entire injection cycles resolved the spatio-temporal fluctuations of the fuel velocity, which occur especially for low injection pressures. Furthermore, a sudden setback of the velocity at the beginning of the injection is identified for various injection pressures. In conclusion, the fast measurement system enables the investigation of the complete temporal behavior of single injection cycles or a series of it. Since this eliminates the necessity of phase-locked measurements, the proposed measurement approach provides new insights for the analysis of high-pressure injections regarding unsteady phenomena.

  9. Intradiskal methylene blue treatment for diskogenic low back pain.

    PubMed

    Levi, David S; Horn, Scott; Walko, Edward

    2014-11-01

    Low back pain is a leading cause of pain and disability. The intervertebral disk has been identified as the most common source of chronic low back pain. Although prior treatments directed at intervertebral disks have been disappointing, recent studies show promising improvement of pain and function after a single intradiskal injection of methylene blue. To assess changes in pain and function in patients with diskogenic low back pain, diagnosed by diskography, after an intradiskal injection of methylene blue. Prospective trial. Patients diagnosed with diskogenic pain by diskography underwent a single treatment of intradiskal injection of methylene blue, determined by prior provocation diskography. Pain and function measurements were completed at baseline and 1, 2, and 6 months after treatment. Treatment was considered a categorical success based on a 30% improvement in pain according to a visual analog scale (VAS) and function on the Oswestry Disability Index (ODI). Treatment was considered a categorical failure if less than 30% improvement in pain and function was achieved or if the patient pursued other invasive treatment options during the trial period. Sixteen patients received the intradiskal methylene blue injection. Eleven patients received a single-level injection, 4 patients received a 2-level injection, and one patient received injections at 3 levels. For the VAS, at 1, 2, and 6 months after the injection, the categorical success rates were 25%, 21%, and 25%, respectively. For the ODI, at 1, 2 and 6 months after the injection, the categorical success rates were 25%, 21%, and 33%, respectively. The overall categorical success rates at 1, 2, and 6 months after the injection were 19%, 21%, and 25%, respectively. This small trial did not demonstrate overall clinical success of intradiskal methylene blue injection for patients diagnosed with diskogenic pain by diskography. Copyright © 2014 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  10. Seismic Borehole Monitoring of CO2 Injection in an Oil Reservoir

    NASA Astrophysics Data System (ADS)

    Gritto, R.; Daley, T. M.; Myer, L. R.

    2002-12-01

    A series of time-lapse seismic cross well and single well experiments were conducted in a diatomite reservoir to monitor the injection of CO2 into a hydrofracture zone, based on P- and S-wave data. A high-frequency piezo-electric P-wave source and an orbital-vibrator S-wave source were used to generate waves that were recorded by hydrophones as well as three-component geophones. The injection well was located about 12 m from the source well. During the pre-injection phase water was injected into the hydrofrac-zone. The set of seismic experiments was repeated after a time interval of 7 months during which CO2 was injected into the hydrofractured zone. The questions to be answered ranged from the detectability of the geologic structure in the diatomic reservoir to the detectability of CO2 within the hydrofracture. Furthermore it was intended to determine which experiment (cross well or single well) is best suited to resolve these features. During the pre-injection experiment, the P-wave velocities exhibited relatively low values between 1700-1900 m/s, which decreased to 1600-1800 m/s during the post-injection phase (-5%). The analysis of the pre-injection S-wave data revealed slow S-wave velocities between 600-800 m/s, while the post-injection data revealed velocities between 500-700 m/s (-6%). These velocity estimates produced high Poisson ratios between 0.36 and 0.46 for this highly porous (~ 50%) material. Differencing post- and pre-injection data revealed an increase in Poisson ratio of up to 5%. Both, velocity and Poisson estimates indicate the dissolution of CO2 in the liquid phase of the reservoir accompanied by a pore-pressure increase. The single well data supported the findings of the cross well experiments. P- and S-wave velocities as well as Poisson ratios were comparable to the estimates of the cross well data.

  11. The ovine fetal endocrine reflex responses to haemorrhage are not mediated by cardiac nerves

    PubMed Central

    Wood, Charles E

    2002-01-01

    This study was designed to test the hypothesis that cardiac receptors tonically inhibit the secretion of renin, arginine vasopressin (AVP) and adrenocorticotropic hormone (ACTH) in late-gestation fetal sheep. Eight chronically catheterised fetal sheep between 122 and 134 days gestation were subjected to injection or infusion of saline or 4 % procaine into the pericardial space. Fetal blood pressure and heart rate were monitored and fetal blood samples were drawn to measure the response to these injections. Injection of procaine into the pericardial space effectively blocked cardiac nerves, as evidenced by a reduction in the variability of fetal heart rate and by the blockade of reflex reductions in fetal heart rate after intravenous injection of phenylephrine (an α-adrenergic agonist which raises blood pressure). Injection of saline had no discernable effects on any of the measured variables. A single injection of procaine, followed by a slow infusion, produced a transient blockade of cardiac nerves. Multiple injections of procaine produced a sustained blockade of cardiac nerves and a sustained rise in fetal plasma renin activity and ACTH. In none of the experiments did procaine significantly alter fetal plasma AVP concentrations. In 11 fetuses between 121 and 134 days gestation, we combined the cardiac nerve blockade with slow haemorrhage to test the cardiac nerves as mediators of the endocrine response to haemorrhage in utero. Cardiac nerve blockade exaggerated the fetal blood gas response to haemorrhage somewhat but did not significantly alter the magnitude of the ACTH, AVP, or plasma renin activity response to haemorrhage. We conclude that cardiac nerves in the late-gestation fetal sheep have minor influences on plasma renin activity and ACTH in normovolaemic fetuses, but that changes in cardiac nerve activity do not mediate the endocrine responsiveness to haemorrhage. PMID:12042365

  12. Studies on piston bowl geometries using single blend ratio of various non-edible oils.

    PubMed

    Viswanathan, Karthickeyan; Pasupathy, Balamurugan

    2017-07-01

    The depletion of fossil fuels and hike in crude oil prices were some of the main reasons to explore new alternatives from renewable source of energy. This work presents the impact of various bowl geometries on diesel engine with diesel and biodiesel samples. Three non-edible oils were selected, namely pumpkin seed oil, orange oil and neem oil. These oils were converted into respective biodiesel using transesterification process in the presence of catalyst and alcohol. After transesterification process, the oils were termed as pumpkin seed oil methyl ester (PSOME), orange oil methyl ester (OME) and neem oil methyl ester (NOME), respectively. The engine used for experimentation was a single-cylinder four-stroke water-cooled direct-injection diesel engine and loads were applied to the engine using eddy current dynamometer. Two bowl geometries were developed, namely toroidal combustion chamber (TCC) and trapezoidal combustion chamber (TRCC). Also, the engine was inbuilt with hemispherical combustion chamber (HCC). The base line readings were recorded using neat diesel fuel with HCC for various loads. Followed by 20% of biodiesel mixed with 80% neat diesel for all prepared methyl esters and termed as B1 (20% PSOME with 80% diesel), B2 (20% OME with 80% diesel) and B3 (20% NOME with 80% diesel). All fuel samples were tested in HCC, TCC and TRCC bowl geometries under standard injection timing and with compression ratio of 18. Increased brake thermal efficiency and reduced brake specific fuel consumption were observed with diesel in TCC geometry. Also, higher heat release and cylinder pressures with lower ignition delay were recorded with TCC bowl geometry. TCC bowl geometry showed lower CO, HC and smoke emissions with B2 fuel sample than diesel and other biodiesel samples. But, higher NOx emission was observed in HCC and TCC than that in TRCC bowl geometry. Graphical abstract ᅟ.

  13. Assessment of the efficacy and safety of single platelet-rich plasma injection on different types and grades of facial wrinkles.

    PubMed

    Elnehrawy, Naema Y; Ibrahim, Zeinab A; Eltoukhy, Azza M; Nagy, Hala M

    2017-03-01

    Platelet-rich plasma (PRP) is considered as a growing modality for tissue regeneration and a developing research area for clinicians and researchers. PRP injection treatment provides supraphysiological concentrations of growth factors that may help in accelerated tissue remodeling and regeneration. To evaluate the efficacy and safety of single autologous PRP intradermal injection for treatment of facial wrinkles and for facial rejuvenation. A total of 20 subjects with different types of facial wrinkles were included in this study. All subjects received single PRP intradermal injection and were clinically assessed before and after treatment for a period of 8 weeks using Wrinkle Severity Rating Scale (WSRS), Skin Homogeneity and Texture (SHnT) Scale, Physician Assessment Scale, and Subject Satisfaction Scale. The mean value of WSRS reduced from 2.90 ± 0.91 before treatment to 2.10 ± 0.79 after 8 weeks of treatment. The most significant results were with younger subjects that have mild and moderate wrinkles of the nasolabial folds (NLFs). Fourteen of seventeen subjects with NLFs showed more than 25% improvement in their appearance. Side effects of PRP treatment were minimal to mild and with excellent tolerability. Single PRP intradermal injection is well tolerated and capable of rejuvenating the face and producing a significant correction of wrinkles especially the NLFs. © 2016 Wiley Periodicals, Inc.

  14. Toxicity of Single-dose Intramuscular Injection of Samjeong Pharmacopuncture in Sprague-Dawley Rats.

    PubMed

    Kwon, Kang; Kim, Chul-Yun; Kim, Nam-Kwen; Sun, Seung-Ho; Seo, Hyung-Sik

    2015-06-01

    This study was carried out in order to find both the single-dose intramuscular injection toxicity and the approximate lethal dose of samjeong pharmacopuncture (SP) in Sprague-Dawley (SD) rats. The SD rats in this study were divided into four groups, one control group (1.0 mL/animal, normal saline) and three experimental groups (0.25, 0.5, and 1.0 mL/animal, SP). All groups consisted of five male and five female rats. SP was injected as a single-dose intramuscularly at the thigh. After the injection, general symptoms and weight were observed for 14 days. After the observations had ended, hematologic and serum biochemical examinations, necropsy and a local tolerance test at the injection site were performed. The experiments were carried out at the Good Laboratory Practice firm, Biotoxtech Co. (Cheongwon, Chungbuk). Animal experiments were approved by the Ethics Committee (Approval Number: 130379). No deaths occurred in any of the three experimental groups. The injection of SP had no effects on the general symptoms, body weights, results of the hematologic, and serum biochemical examinations, and necropsy findings. In local tolerance tests at the injection sites, mild inflammation was observed in the experimental group, but it did not appear to be a treatment related effect. Under the conditions of this test, the results from the injection of SP suggest that the approximate lethal dose of SP is above 1.0 mL/animal for both male and female SD rats. Therefore, the clinical use of SP is thought to be safe.

  15. Will a single periarticular lidocaine-corticosteroid injection improve the clinical efficacy of intraarticular hyaluronic acid treatment of symptomatic knee osteoarthritis?

    PubMed

    Ertürk, Cemil; Altay, Mehmet Akif; Altay, Nuray; Kalender, Ali Murat; Öztürk, İbrahim Avşin

    2016-11-01

    A local injection of corticosteroid-lidocaine into the periarticular soft tissue structures is used commonly for rapid pain relief. It is hypothesized that knee pain associated with knee osteoarthritis would be relieved quickly and effectively in patients receiving intraarticular hyaluronic acid combined with a periarticular lidocaine-corticosteroid injection. To test this hypothesis, the clinical effect of the combined treatment with hyaluronic acid injection alone in patients with symptomatic knee osteoarthritis as compared in this prospective single-blinded randomized trial. This study included 70 patients. Group 1 (n = 35) received intraarticular hyaluronic acid injections only, whereas group 2 (n = 35) received intraarticular hyaluronic acid injections combined with a single local injection of corticosteroid-lidocaine. Injections were administered to the most painful areas of the anterior or posterior medial condyle of the femur or tibia. The outcome was measured by independent assessors (blinded to treatment) using a linear VAS pain scale and WOMAC and HSS knee scores. Assessments were performed at baseline and at 1, 3, 6, 12, 26, and 52 weeks. During the first 3 weeks, group 2 patients showed significantly better all scores than did group 1 patients (p < 0.01). However, no significant differences were detected at 6, 12, 26 or 52 weeks (n.s.). The combined treatment may lead to earlier pain relief compared with intraarticular hyaluronic acid alone in patients with knee osteoarthritis and can be considered a useful adjunctive treatment modality. This combined method may provide early return to patient's daily activity. Therapeutic study, Level I.

  16. Physical and chemical stability of pemetrexed in infusion solutions.

    PubMed

    Zhang, Yanping; Trissel, Lawrence A

    2006-06-01

    Pemetrexed is a multitargeted, antifolate, antineoplastic agent that is indicated for single-agent use in locally advanced or metastatic non-small-cell lung cancer after prior chemotherapy and in combination with cisplatin for the treatment of malignant pleural mesothelioma not treatable by surgery. Currently, there is no information on the long-term stability of pemetrexed beyond 24 hours. To evaluate the longer-term physical and chemical stability of pemetrexed 2, 10, and 20 mg/mL in polyvinyl chloride (PVC) bags of dextrose 5% injection and NaCl 0.9% injection. Triplicate samples of pemetrexed were prepared in the concentrations and infusion solutions required. Evaluations for physical and chemical stability were performed initially and over 2 days at 23 degrees C protected from light and exposed to fluorescent light, and over 31 days of storage at 4 degrees C protected from light. Physical stability was assessed using turbidimetric and particulate measurement as well as visual observation. Chemical stability was evaluated by HPLC. All pemetrexed solutions remained chemically stable, with little or no loss of pemetrexed over 2 days at 23 degrees C, protected from light and exposed to fluorescent light, and over 31 days of storage at 4 degrees C, protected from light. The room temperature samples were physically stable throughout the 48 hour test period. However, pemetrexed admixtures developed large numbers of microparticulates during refrigerated storage exceeding 24 hours. Pemetrexed is chemically stable for 2 days at room temperature and 31 days refrigerated in dextrose 5% injection and NaCl 0.9% injection. However, substantial numbers of microparticulates may form in pemetrexed diluted in the infusion solutions in PVC bags, especially during longer periods of refrigerated storage. Limiting the refrigerated storage period to the manufacturer-recommended 24 hours will limit particulate formation.

  17. RCT of an integrated CBT-HIV intervention on depressive symptoms and HIV risk.

    PubMed

    Tobin, Karin; Davey-Rothwell, Melissa A; Nonyane, Bareng A S; Knowlton, Amy; Wissow, Lawrence; Latkin, Carl A

    2017-01-01

    Depression and depressive symptoms mediate the association between drug use and HIV risk. Yet, there are few interventions that target depressive symptoms and HIV risk for people who use drugs (PWUD). This study was a randomized controlled trial of an integrated cognitive behavioral therapy and HIV prevention intervention to reduce depressive symptoms, injection risk behaviors and increase condom use in a sample of urban people who used heroin or cocaine in the prior 6 months. A total of 315 individuals aged 18-55, who self-reported at least one HIV drug and sex risk behavior and scored ≥16 and <40 on the Centers for Epidemiologic Studies-Depression (CES-D) scale were randomized using a two-block design, stratified by sex to ensure equivalent numbers, to a 10 session intervention arm (n = 162) or a single session control arm (n = 153). The outcomes of interest were decreases in CES-D score and injection risk behaviors and increases in condom use. The sample was majority African American (85%) and unemployed (94%). Nearly half (47%) reported injection in the prior 6 months and only 19% were taking medication for depression. Follow-up assessments were conducted at 6 and 12 months. Retention at 12 months was 94%. Intervention arm was associated with statistically significantly lower CES-D score at 12 month compared to control. No differences were observed between arms in injection risk. At 6 month, intervention was associated with greater odds of condom use with non-main partner. These findings suggest the potential role of the integrated intervention in reducing depressive symptoms, but weak impact on HIV risk. This trial is registered with ClinicalTrials.gov under the title "Neighborhoods, Networks, Depression, and HIV Risk" number NCT01380613.

  18. A systematic review of four injection therapies for lateral epicondylosis: prolotherapy, polidocanol, whole blood and platelet rich plasma

    PubMed Central

    Best, Thomas M.; Zgierska, Aleksandra E.; Zeisig, Eva; Ryan, Michael; Crane, David

    2009-01-01

    Objective To appraise existing evidence for prolotherapy, polidocanol, autologous whole blood and platelet-rich plasma injection therapies for lateral epicondylosis (LE) Design Systematic Review Data sources Medline, Embase, CINAHL, Cochrane Central Register of Controlled Trials, Allied and Complementary Medicine. Search strategy: names and descriptors of the therapies and LE. Study Selection All human studies assessing the four therapies for LE. Main results Results of five prospective case series and four controlled trials (3 prolotherapy, 2 polidocanol, 3 autologous whole blood and 1 platelet-rich plasma) suggest each of the four therapies is effective for LE. In follow-up periods ranging from 9 to 108 weeks, studies reported sustained, statistically significant(p<0.05) improvement on visual analog scale primary outcome pain score measures and disease specific questionnaires; relative effect sizes ranged from 51% to 94%; Cohen’s d ranged from 0.68 to 6.68. Secondary outcomes also improved, including biomechanical elbow function assessment (polidocanol and prolotherapy), presence of abnormalities and increased vascularity on ultrasound (autologous whole blood and polidocanol). Subjects reported satisfaction with therapies on single-item assessments. All studies were limited by small sample size. Conclusions There is strong pilot-level evidence supporting the use of prolotherapy, polidocanol, autologous whole blood and platelet-rich plasma injections in the treatment of LE. Rigorous studies of sufficient sample size, assessing these injection therapies using validated clinical, radiological and biomechanical measures, and tissue injury/healing-responsive biomarkers, are needed to determine long-term effectiveness and safety, and whether these techniques can play a definitive role in the management of LE and other tendinopathies. PMID:19028733

  19. Pharmacokinetics of a single intramuscular injection of ceftiofur crystalline-free acid in red-tailed hawks (Buteo jamaicensis).

    PubMed

    Sadar, Miranda J; Hawkins, Michelle G; Byrne, Barbara A; Cartoceti, Andrew N; Keel, Kevin; Drazenovich, Tracy L; Tell, Lisa A

    2015-12-01

    To determine the pharmacokinetics and adverse effects at the injection site of ceftiofur crystalline-free acid (CCFA) following IM administration of 1 dose to red-tailed hawks (Buteo jamaicensis). 7 adult nonreleasable healthy red-tailed hawks. In a randomized crossover study, CCFA (10 or 20 mg/kg) was administered IM to each hawk and blood samples were obtained. After a 2-month washout period, administration was repeated with the opposite dose. Muscle biopsy specimens were collected from the injection site 10 days after each sample collection period. Pharmacokinetic data were calculated. Minimum inhibitory concentrations of ceftiofur for various bacterial isolates were assessed. Mean peak plasma concentrations of ceftiofur-free acid equivalent were 6.8 and 15.1 μg/mL for the 10 and 20 mg/kg doses, respectively. Mean times to maximum plasma concentration were 6.4 and 6.7 hours, and mean terminal half-lives were 29 and 50 hours, respectively. Little to no muscle inflammation was identified. On the basis of a target MIC of 1 μg/mL and target plasma ceftiofur concentration of 4 μg/mL, dose administration frequencies for infections with gram-negative and gram-positive organisms were estimated as every 36 and 45 hours for the 10 mg/kg dose and every 96 and 120 hours for the 20 mg/kg dose, respectively. Study results suggested that CCFA could be administered IM to red-tailed hawks at 10 or 20 mg/kg to treat infections with ceftiofur-susceptible bacteria. Administration resulted in little to no inflammation at the injection site. Additional studies are needed to evaluate effects of repeated CCFA administration.

  20. Dynamic chirp control of all-optical format-converted pulsed data from a multi-wavelength inverse-optical-comb injected semiconductor optical amplifier.

    PubMed

    Lin, Gong-Ru; Pan, Ci-Ling; Yu, Kun-Chieh

    2007-10-01

    By spectrally and temporally reshaping the gain-window of a traveling-wave semiconductor optical amplifier (TWSOA) with a backward injected multi- or single-wavelength inverse-optical-comb, we theoretically and experimentally investigate the dynamic frequency chirp of the all-optical 10GBit/s Return-to-Zero (RZ) data-stream format-converted from the TWSOA under strong cross-gain depletion scheme. The multi-wavelength inverse-optical-comb injection effectively depletes the TWSOA gain spectrally and temporally, remaining a narrow gain-window and a reduced spectral linewidth and provide a converted RZ data with a smaller peak-to-peak frequency chirp of 6.7 GHz. Even at high inverse-optical-comb injection power and highly biased current condition for improving the operational bit-rate, the chirp of the multi-wavelength-injection converted RZ pulse is still 2.1-GHz smaller than that obtained by using single-wavelength injection at a cost of slight pulse-width broadening by 1 ps.

  1. Pseudorandom binary injection of levitons for electron quantum optics

    NASA Astrophysics Data System (ADS)

    Glattli, D. C.; Roulleau, P.

    2018-03-01

    The recent realization of single-electron sources lets us envision performing electron quantum optics experiments, where electrons can be viewed as flying qubits propagating in a ballistic conductor. To date, all electron sources operate in a periodic electron injection mode, leading to energy spectrum singularities in various physical observables which sometimes hide the bare nature of physical effects. To go beyond this, we propose a spread-spectrum approach where electron flying qubits are injected in a nonperiodic manner following a pseudorandom binary bit pattern. Extending the Floquet scattering theory approach from periodic to spread-spectrum drive, the shot noise of pseudorandom binary sequences of single-electron injection can be calculated for leviton and nonleviton sources. Our new approach allows us to disentangle the physics of the manipulated excitations from that of the injection protocol. In particular, the spread-spectrum approach is shown to provide better knowledge of electronic Hong-Ou-Mandel correlations and to clarify the nature of the pulse train coherence and the role of the dynamical orthogonality catastrophe for noninteger charge injection.

  2. StereoTactic radiotherapy for wet Age-Related macular degeneration (STAR): study protocol for a randomised controlled clinical trial.

    PubMed

    Neffendorf, James E; Desai, Riti; Wang, Yanzhong; Kelly, Joanna; Murphy, Caroline; Reeves, Barnaby C; Chakravarthy, Usha; Wordsworth, Sarah; Lewis, Cornelius; Peacock, Janet; Uddin, Shahir; O'Sullivan, Joe M; Jackson, Timothy L

    2016-11-24

    The standard of care for neovascular age-related macular degeneration (nAMD) involves ongoing intravitreal injections of anti-angiogenic drugs targeting vascular endothelial growth factor (VEGF). The most commonly used anti-VEGF drugs are ranibizumab, bevacizumab and aflibercept. The main objective of the STAR trial is to determine if stereotactic radiotherapy can reduce the number of anti-VEGF injections that patients with nAMD require. STAR is a multicentre, double-masked, randomised, sham-controlled clinical trial. It evaluates a new device (manufactured by Oraya, Newark, CA, USA) designed to deliver stereotactic radiotherapy (SRT) to nAMD lesions. The trial enrols participants with chronic, active nAMD. Participants receive a single SRT treatment (16 Gy or sham) with a concomitant baseline intravitreal injection of 0.5 mg ranibizumab. Thereafter, they attend every month for 24 months, and ranibizumab is administered at the visit if retreatment criteria are met. The primary outcome is the number of pro re nata ranibizumab injections during the first 24 months. Secondary outcomes include visual acuity, lesion morphology, quality of life and safety. Additional visits occur at 36 and 48 months to inspect for radiation retinopathy. The target sample size of 411 participants (randomised 2:1 in favour of radiation) is designed to detect a reduction of 2.5 injections against ranibizumab monotherapy, at 90% power, and a significance level (alpha) of 0.025 (one-sided two-sample t test). This gives 97% power to detect non-inferiority of visual acuity at a five-letter margin. The primary analyses will be by intention to treat. The safety and efficacy outcomes will help determine the role of SRT in the management of chronic, active nAMD. International Standard Randomised Controlled Trial Number: ISRCTN12884465. Registered on 28 November 2014. ClinicalTrials.gov: NCT02243878 . Registered on 17 September 2014.

  3. Enhancing concentration and mass sensitivities for liquid chromatography trace analysis of clopyralid in drinking water.

    PubMed

    Gu, Binghe; Meldrum, Brian; McCabe, Terry; Phillips, Scott

    2012-01-01

    A theoretical treatment was developed and validated that relates analyte concentration and mass sensitivities to injection volume, retention factor, particle diameter, column length, column inner diameter and detection wavelength in liquid chromatography, and sample volume and extracted volume in solid-phase extraction (SPE). The principles were applied to improve sensitivity for trace analysis of clopyralid in drinking water. It was demonstrated that a concentration limit of detection of 0.02 ppb (μg/L) for clopyralid could be achieved with the use of simple UV detection and 100 mL of a spiked drinking water sample. This enabled reliable quantitation of clopyralid at the targeted 0.1 ppb level. Using a buffered solution as the elution solvent (potassium acetate buffer, pH 4.5, containing 10% of methanol) in the SPE procedures was found superior to using 100% methanol, as it provided better extraction recovery (70-90%) and precision (5% for a concentration at 0.1 ppb level). In addition, the eluted sample was in a weaker solvent than the mobile phase, permitting the direct injection of the extracted sample, which enabled a faster cycle time of the overall analysis. Excluding the preparation of calibration standards, the analysis of a single sample, including acidification, extraction, elution and LC run, could be completed in 1 h. The method was used successfully for the determination of clopyralid in over 200 clopyralid monoethanolamine-fortified drinking water samples, which were treated with various water treatment resins. Copyright © 2012 WILEY‐VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Effects of Botulinum Toxin on Jaw Motor Events during Sleep in Sleep Bruxism Patients: A Polysomnographic Evaluation

    PubMed Central

    Shim, Young Joo; Lee, Moon Kyu; Kato, Takafumi; Park, Hyung Uk; Heo, Kyoung; Kim, Seong Taek

    2014-01-01

    Study Objectives: To investigate the effects of botulinum toxin type A (BoNT-A) injection on jaw motor episodes during sleep in patients with or without orofacial pain who did not respond to oral splint treatment. Methods: Twenty subjects with a clinical diagnosis of SB completed this study. Ten subjects received bilateral BoNT-A injections (25 U per muscle) into the masseter muscles only (group A), and the other 10 received the injections into both the masseter and temporalis muscles (group B). Video-polysomnographic (vPSG) recordings were made before and at 4 weeks after injection. Rhythmic masticatory muscle activity (RMMA) and orofacial activity (OFA) were scored and analyzed for several parameters (e.g., frequency of episodes, bursts per episode, episode duration). The peak amplitude of electromyographic (EMG) activity in the two muscles was also measured. Results: BoNT-A injection did not reduce the frequency, number of bursts, or duration for RMMA episodes in the two groups. The injection decreased the peak amplitude of EMG burst of RMMA episodes in the injected muscles (p < 0.001, repeated measure ANOVA) in both groups. At 4 weeks after injection, 9 subjects self-reported reduction of tooth grinding and 18 subjects self-reported reduction of morning jaw stiffness. Conclusions: A single BoNT-A injection is an effective strategy for controlling SB for at least a month. It reduces the intensity rather than the generation of the contraction in jaw-closing muscles. Future investigations on the efficacy and safety in larger samples over a longer follow-up period are needed before establishing management strategies for SB with BoNT-A. Citation: Shim YJ; Lee MK; Kato T; Park HU; Heo K; Kim ST. Effects of botulinum toxin on jaw motor events during sleep in sleep bruxism patients: a polysomnographic evaluation. J Clin Sleep Med 2014;10(3):291-298. PMID:24634627

  5. Injected carrier concentration dependence of the expansion of single Shockley-type stacking faults in 4H-SiC PiN diodes

    NASA Astrophysics Data System (ADS)

    Tawara, T.; Matsunaga, S.; Fujimoto, T.; Ryo, M.; Miyazato, M.; Miyazawa, T.; Takenaka, K.; Miyajima, M.; Otsuki, A.; Yonezawa, Y.; Kato, T.; Okumura, H.; Kimoto, T.; Tsuchida, H.

    2018-01-01

    We investigated the relationship between the dislocation velocity and the injected carrier concentration on the expansion of single Shockley-type stacking faults by monitoring the electroluminescence from 4H-SiC PiN diodes with various anode Al concentrations. The injected carrier concentration was calculated using a device simulation that took into account the measured accumulated charge in the drift layer during diode turn-off. The dislocation velocity was strongly dependent on the injected hole concentration, which represents the excess carrier concentration. The activation energy of the dislocation velocity was quite small (below 0.001 eV between 310 and 386 K) over a fixed range of hole concentrations. The average threshold hole concentration required for the expansion of bar-shaped single Shockley-type stacking faults at the interface between the buffer layer and the substrate was determined to be 1.6-2.5 × 1016 cm-3 for diodes with a p-type epitaxial anode with various Al concentrations.

  6. Single well tracer method to evaluate enhanced recovery

    DOEpatents

    Sheely, Jr., Clyde Q.; Baldwin, Jr., David E.

    1978-01-01

    Data useful to evaluate the effectiveness of or to design an enhanced recovery process (the recovery process involving mobilizing and moving hydrocarbons through a hydrocarbon-bearing subterranean formation from an injection well to a production well by injecting a mobilizing fluid into the injection well) are obtained by a process which comprises sequentially: determining hydrocarbon saturation in the formation in a volume in the formation near a well bore penetrating the formation, injecting sufficient of the mobilizing fluid to mobilize and move hydrocarbons from a volume in the formation near the well bore penetrating the formation, and determining by the single well tracer method a hydrocarbon saturation profile in a volume from which hydrocarbons are moved. The single well tracer method employed is disclosed by U.S. Pat. No. 3,623,842. The process is useful to evaluate surfactant floods, water floods, polymer floods, CO.sub.2 floods, caustic floods, micellar floods, and the like in the reservoir in much less time at greatly reduced costs, compared to conventional multi-well pilot test.

  7. Temperature-assisted solute focusing with sequential trap/release zones in isocratic and gradient capillary liquid chromatography: Simulation and experiment

    PubMed Central

    Groskreutz, Stephen R.; Weber, Stephen G.

    2016-01-01

    In this work we characterize the development of a method to enhance temperature-assisted on-column solute focusing (TASF) called two-stage TASF. A new instrument was built to implement two-stage TASF consisting of a linear array of three independent, electronically controlled Peltier devices (thermoelectric coolers, TECs). Samples are loaded onto the chromatographic column with the first two TECs, TEC A and TEC B, cold. In the two-stage TASF approach TECs A and B are cooled during injection. TEC A is heated following sample loading. At some time following TEC A’s temperature rise, TEC B’s temperature is increased from the focusing temperature to a temperature matching that of TEC A. Injection bands are focused twice on-column, first on the initial TEC, e.g. single-stage TASF, then refocused on the second, cold TEC. Our goal is to understand the two-stage TASF approach in detail. We have developed a simple yet powerful digital simulation procedure to model the effect of changing temperature in the two focusing zones on retention, band shape and band spreading. The simulation can predict experimental chromatograms resulting from spatial and temporal temperature programs in combination with isocratic and solvent gradient elution. To assess the two-stage TASF method and the accuracy of the simulation well characterized solutes are needed. Thus, retention factors were measured at six temperatures (25–75 °C) at each of twelve mobile phases compositions (0.05–0.60 acetonitrile/water) for homologs of n-alkyl hydroxylbenzoate esters and n-alkyl p-hydroxyphenones. Simulations accurately reflect experimental results in showing that the two-stage approach improves separation quality. For example, two-stage TASF increased sensitivity for a low retention solute by a factor of 2.2 relative to single-stage TASF and 8.8 relative to isothermal conditions using isocratic elution. Gradient elution results for two-stage TASF were more encouraging. Application of two-stage TASF increased peak height for the least retained solute in the test mixture by a factor of 3.2 relative to single-stage TASF and 22.3 compared to isothermal conditions for an injection four-times the column volume. TASF improved resolution and increased peak capacity; for a 12-minute separation peak capacity increased from 75 under isothermal conditions to 146 using single-stage TASF, and 185 for two-stage TASF. PMID:27836226

  8. Temperature-assisted solute focusing with sequential trap/release zones in isocratic and gradient capillary liquid chromatography: Simulation and experiment.

    PubMed

    Groskreutz, Stephen R; Weber, Stephen G

    2016-11-25

    In this work we characterize the development of a method to enhance temperature-assisted on-column solute focusing (TASF) called two-stage TASF. A new instrument was built to implement two-stage TASF consisting of a linear array of three independent, electronically controlled Peltier devices (thermoelectric coolers, TECs). Samples are loaded onto the chromatographic column with the first two TECs, TEC A and TEC B, cold. In the two-stage TASF approach TECs A and B are cooled during injection. TEC A is heated following sample loading. At some time following TEC A's temperature rise, TEC B's temperature is increased from the focusing temperature to a temperature matching that of TEC A. Injection bands are focused twice on-column, first on the initial TEC, e.g. single-stage TASF, then refocused on the second, cold TEC. Our goal is to understand the two-stage TASF approach in detail. We have developed a simple yet powerful digital simulation procedure to model the effect of changing temperature in the two focusing zones on retention, band shape and band spreading. The simulation can predict experimental chromatograms resulting from spatial and temporal temperature programs in combination with isocratic and solvent gradient elution. To assess the two-stage TASF method and the accuracy of the simulation well characterized solutes are needed. Thus, retention factors were measured at six temperatures (25-75°C) at each of twelve mobile phases compositions (0.05-0.60 acetonitrile/water) for homologs of n-alkyl hydroxylbenzoate esters and n-alkyl p-hydroxyphenones. Simulations accurately reflect experimental results in showing that the two-stage approach improves separation quality. For example, two-stage TASF increased sensitivity for a low retention solute by a factor of 2.2 relative to single-stage TASF and 8.8 relative to isothermal conditions using isocratic elution. Gradient elution results for two-stage TASF were more encouraging. Application of two-stage TASF increased peak height for the least retained solute in the test mixture by a factor of 3.2 relative to single-stage TASF and 22.3 compared to isothermal conditions for an injection four-times the column volume. TASF improved resolution and increased peak capacity; for a 12-min separation peak capacity increased from 75 under isothermal conditions to 146 using single-stage TASF, and 185 for two-stage TASF. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Single-step enantioselective amino acid flux analysis by capillary electrophoresis using on-line sample preconcentration with chemical derivatization.

    PubMed

    Ptolemy, Adam S; Tran, Lara; Britz-McKibbin, Philip

    2006-07-15

    Capillary electrophoresis (CE) represents a versatile platform for integrating sample pretreatment with chemical analysis because of its ability to tune analyte electromigration and band dispersion properties in discontinuous electrolyte systems. In this article, a single-step method that combines on-line sample preconcentration with in-capillary chemical derivatization is developed for rapid, sensitive, and enantioselective analysis of micromolar levels of amino acids that lack intrinsic chromophores by CE with UV detection. Time-resolved electrophoretic studies revealed two distinct stages of amino acid band narrowing within the original long sample injection plug occurring both prior to and after in-capillary labeling via zone passing by ortho-phthalaldehyde/N-acetyl l-cysteine (OPA/NAC). This technique enabled direct analysis of d-amino acids in a 95% enantiomeric excess mixture with sub-micromolar detection limits and minimal sample handling, where the capillary functions as a preconcentrator, microreactor, and chiral selector. On-line sample preconcentration with chemical derivatization CE (SPCD-CE) was applied to study the enantioselective amino acid flux in Escherichia coli bacteria cultures, which demonstrated a unique l-Ala efflux into the extracellular medium. New strategies for high-throughput analyses of low-abundance metabolites are important for understanding fundamental physiological processes in bacteria required for screening the efficacy of new classes of antibiotics as well as altered metabolism in genetically modified mutant strains.

  10. Effect of a single injection of autologous conditioned serum (ACS) on tendon healing in equine naturally occurring tendinopathies.

    PubMed

    Geburek, Florian; Lietzau, Maren; Beineke, Andreas; Rohn, Karl; Stadler, Peter M

    2015-06-26

    Autologous blood-derived biologicals, including autologous conditioned serum (ACS), are frequently used to treat tendinopathies in horses despite limited evidence for their efficacy. The purpose of this study was to describe the effect of a single intralesional injection of ACS in naturally occurring tendinopathies of the equine superficial digital flexor tendon (SDFT) on clinical, ultrasonographic, and histological parameters. Fifteen horses with 17 naturally occurring tendinopathies of forelimb SDFTs were examined clinically and ultrasonographically (day 0). Injured tendons were randomly assigned to the ACS-treated group (n = 10) receiving a single intralesional ACS injection or included as controls (n = 7) which were either untreated or injected with saline on day 1. All horses participated in a gradually increasing exercise programme and were re-examined nine times at regular intervals until day 190. Needle biopsies were taken from the SDFTs on days 0, 36 and 190 and examined histologically and for the expression of collagen types I and III by immunohistochemistry. In ACS-treated limbs lameness decreased significantly until day 10 after treatment. Swelling (scores) of the SDFT region decreased within the ACS group between 50 and 78 days after treatment. Ultrasonographically, the percentage of the lesion in the tendon was significantly lower and the echogenicity of the lesion (total echo score) was significantly higher 78 and 106 days after intralesional ACS injection compared to controls. Histology revealed that, compared to controls, tenocyte nuclei were more spindle-shaped 36 days after ACS injection. Immunohistochemistry showed that collagen type I expression significantly increased between days 36 and 190 after ACS injection. Single intralesional ACS injection of equine SDFTs with clinical signs of acute tendinopathy contributes to an early significant reduction of lameness and leads to temporary improvement of ultrasonographic parameters of repair tissue. Intralesional ACS treatment might decrease proliferation of tenocytes 5 weeks after treatment and increase their differentiation as demonstrated by elevated collagen type I expression in the remodelling phase. Potential enhancement of these effects by repeated injections should be tested in future controlled clinical investigations.

  11. Flow injection amperometric detection of insulin at cobalt hydroxide nanoparticles modified carbon ceramic electrode.

    PubMed

    Habibi, Esmaeil; Omidinia, Eskandar; Heidari, Hassan; Fazli, Maryam

    2016-02-15

    Cobalt hydroxide nanoparticles were prepared onto a carbon ceramic electrode (CHN|CCE) using the cyclic voltammetry (CV) technique. The modified electrode was characterized by X-ray diffraction and scanning electron microscopy. The results showed that CHN with a single-layer structure was uniformly electrodeposited on the surface of CCE. The electrocatalytic activity of the modified electrode toward the oxidation of insulin was studied by CV. CHN|CCE was also used in a homemade flow injection analysis system for insulin determination. The limit of detection (signal/noise [S/N] = 3) and sensitivity were found to be 0.11 nM and 11.8 nA/nM, respectively. Moreover, the sensor was used for detection of insulin in human serum samples. This sensor showed attractive properties such as high stability, reproducibility, and high selectivity. Copyright © 2015 Elsevier Inc. All rights reserved.

  12. Clinically relevant behavioral endpoints in a recurrent nitroglycerin migraine model in rats.

    PubMed

    Sufka, Kenneth J; Staszko, Stephanie M; Johnson, Ainslee P; Davis, Morgan E; Davis, Rachel E; Smitherman, Todd A

    2016-01-01

    This research sought to further validate the rat nitroglycerin (NTG) migraine model by comparing the effects of single versus recurrent NTG episodes on behavioral endpoints that mirror ICHD-3 diagnostic criteria for migraine, and to determine if the altered behavioral endpoints are reduced after administration of sumatriptan. Separate cohorts of rats were administered NTG (10 mg/kg/2 ml) or saline (Experiment 1: single injection; Experiment 2: repeated injections; Experiment 3: repeated injections with sumatriptan [0.0, 0.3 and 1.0 mg/kg/ml] rescue. Behavioral endpoints were assessed 2 h after final NTG administration and included time in light/dark chambers for photophobia and activity, pain facial ratings, and cool (5 °C) and warm (46 °C) tail dip. The first two experiments demonstrated that repeated (n = 5) but not single NTG injections produced photophobia, decreased activity, and yielded less weight gain than saline injections. Experiment 3 showed that sumatriptan attenuated hypoactivity, reduced facial expressions of pain, and reversed weight alterations in a dose-dependent manner. These findings identify numerous clinical homologies of a recurrent NTG rat migraine model that may be useful for screening novel pharmacotherapies.

  13. Quality investigation of hydroxyprogesterone caproate active pharmaceutical ingredient and injection

    PubMed Central

    Chollet, John L.; Jozwiakowski, Michael J.

    2012-01-01

    The purpose of this study was to investigate the quality of hydroxyprogesterone caproate (HPC) active pharmaceutical ingredient (API) sources that may be used by compounding pharmacies, compared to the FDA-approved source of the API; and to investigate the quality of HPC injection samples obtained from compounding pharmacies in the US, compared to the FDA-approved product (Makena®). Samples of API were obtained from every source confirmed to be an original manufacturer of the drug for human use, which were all companies in China that were not registered with FDA. Eight of the ten API samples (80%) did not meet the impurity specifications required by FDA for the API used in the approved product. One API sample was found to not be HPC at all; additional laboratory testing showed that it was glucose. Thirty samples of HPC injection obtained from com pounding pharmacies throughout the US were also tested, and eight of these samples (27%) failed to meet the potency requirement listed in the USP monograph for HPC injection and/or the HPLC assay. Sixteen of the thirty injection samples (53%) exceeded the impurity limit setforthe FDA-approved drug product. These results confirm the inconsistency of compounded HPC Injections and suggest that the risk-benefit ratio of using an unapproved compounded preparation, when an FDA-approved drug product is available, is not favorable. PMID:22329865

  14. Embryonic stem cells improve skeletal muscle recovery after extreme atrophy in mice.

    PubMed

    Artioli, Guilherme Giannini; De Oliveira Silvestre, João Guilherme; Guilherme, João Paulo Limongi França; Baptista, Igor Luchini; Ramos, Gracielle Vieira; Da Silva, Willian José; Miyabara, Elen Haruka; Moriscot, Anselmo Sigari

    2015-03-01

    We injected embryonic stem cells into mouse tibialis anterior muscles subjected to botulinum toxin injections as a model for reversible neurogenic atrophy. Muscles were exposed to botulinum toxin for 4 weeks and allowed to recover for up to 6 weeks. At the onset of recovery, a single muscle injection of embryonic stem cells was administered. The myofiber cross-sectional area, single twitch force, peak tetanic force, time-to-peak force, and half-relaxation time were determined. Although the stem cell injection did not affect the myofiber cross-sectional area gain in recovering muscles, most functional parameters improved significantly compared with those of recovering muscles that did not receive the stem cell injection. Muscle function recovery was accelerated by embryonic stem cell delivery in this durable neurogenic atrophy model. We conclude that stem cells should be considered a potential therapeutic tool for recovery after extreme skeletal muscle atrophy. © 2014 Wiley Periodicals, Inc.

  15. BEVACIZUMAB LEVELS IN BREAST MILK AFTER LONG-TERM INTRAVITREAL INJECTIONS.

    PubMed

    McFarland, Trevor J; Rhoads, Andrew D; Hartzell, Matthew; Emerson, Geoffrey G; Bhavsar, Abdhish R; Stout, J Timothy

    2015-08-01

    The purpose of this study is to determine whether bevacizumab is detectable in the breast milk of nursing mothers. Breast milk samples were collected from 2 patients receiving monthly intravitreal bevacizumab injections for choroidal neovascularization over the course of 16 months. Enzyme-linked immunosorbent assay and Western blot analysis was used to determine the levels of bevacizumab in the milk samples. An enzyme-linked immunosorbent assay was developed using antibodies specific to bevacizumab in which the sensitivity threshold was 3 ng/mL. All breast milk samples assayed from the two patients actively undergoing treatment did not have detectable levels of bevacizumab. Samples collected 1.5 hours and 7 hours after an injection and 2 randomly chosen samples were negative by Western blot analysis. A sensitive assay to detect bevacizumab in breast milk samples assayed suggests that intravitreal injections do not result in detectable bevacizumab in breast milk.

  16. Effect of single and repeated injections of selective D2-antagonist clebopride on maternal behavior of albino rats.

    PubMed

    Tanaeva, K K; Dobryakova, Yu V; Dubynin, V A; Kamensky, A A

    2012-06-01

    This study examined the effect of clebopride at low concentration that did not modify the motor activity on the parental care in female albino rats. Single injection of the drug attenuated the parental care reactions on postinjection minute 20, but not one day thereafter. The daily injection of the drug during the post partum period (1-6 days) resulted in significantly more pronounced and stable effects. The data obtained substantiated the views on the major contribution of D(2)-receptors in the development of behavioral manifestations of puerperal depression.

  17. A study for characterization of IgE-mediated cutaneous immediate and late-phase reactions in non-allergic domestic cats.

    PubMed

    Seals, Shanna L; Kearney, Michael; Del Piero, Fabio; Hammerberg, Bruce; Pucheu-Haston, Cherie M

    2014-05-15

    Immunoglobulin-E (IgE) mediated reactions can be induced by intradermal injection of anti-IgE antibodies in both humans and dogs. These reactions grossly and histologically mimic changes seen in naturally occurring allergic dermatitis in these species. Similar studies have not been conducted in the cat. Purified polyclonal rabbit-origin IgG specific for canine IgE (anti-IgE) and rabbit immunoglobulin G (IgG) were injected intradermally in 7 non-allergic laboratory colony cats. Wheal measurements were obtained and biopsies collected before injection and at injection sites after 20 min, 6, 24, and 48 h. Injection of anti-IgE induced an immediate wheal response which was significantly larger than that seen after injection of rabbit IgG. Anti-IgE injected skin was also significantly thicker than IgG-injected skin. This corresponded with a significant increase in number of visibly degranulated mast cells in anti-IgE samples when compared to IgG samples. Injection of anti-IgE was associated with the rapid recruitment of inflammatory cells to the injected dermis. The number of inflammatory cells and mononuclear cells were significantly elevated after the injection of anti-IgE when compared to IgG-injected skin. Both eosinophils and neutrophils were significantly increased in anti-IgE samples relative to IgG, although neutrophils were only transiently increased. The high eosinophil and relatively low neutrophil cell counts in these samples were consistent with previously documented histologic features of naturally occurring feline allergic skin disease. Immunohistochemistry identified a significantly overall increased CD1a(+) cells after the intradermal injection of anti-IgE when compared to IgG and non-injected skin. CD3(+), CD8(+) and CD4(+) were also significantly increased overall in anti-IgE injected skin relative to IgG injected skin. These data document the gross and cellular response to injection of anti-IgE in the skin of healthy, non-allergic cats and support a possible role for IgE in the development of feline allergic dermatitis. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. Multilineage hematopoietic recovery by a single injection of pegylated recombinant human megakaryocyte growth and development factor in myelosuppressed mice.

    PubMed

    Shibuya, K; Akahori, H; Takahashi, K; Tahara, E; Kato, T; Miyazaki, H

    1998-01-01

    Previous studies have shown that daily multiple administration of pegylated recombinant human megakaryocyte growth and development factor (PEG-rHuMGDF) markedly stimulates thrombopoiesis and effectively ameliorates thrombocytopenia, and in most cases anemia and neutropenia, in myelosuppressed animals. In this study, we evaluated the effects of a single intravenous injection of PEG-rHuMGDF on hematopoietic recovery after sublethal total-body irradiation in mice. A single injection of PEG-rHuMGDF (1 to 640 microg/kg) 1 hour after irradiation accelerated platelet, red blood cell (RBC), and white blood cell (WBC) recovery in a dose-dependent fashion. In the bone marrow of vehicle-treated mice, megakaryocytic, erythroid, and myeloid progenitors, as well as day 12 colony-forming unit-spleen (CFU-S), were dramatically decreased much earlier than the nadirs of peripheral blood cells, whereas megakaryocytes were modestly decreased. Treatment with PEG-rHuMGDF (80 microg/kg, an optimal dose) 1 hour after irradiation resulted in more rapid recovery of these four hematopoietic progenitors and also significantly facilitated megakaryocyte recovery. In addition, the same PEG-rHuMGDF administration schedule expanded bone marrow cells capable of rescuing lethally irradiated recipient mice. As the interval between irradiation and PEG-rHuMGDF treatment was longer, its effects on hematopoietic recovery were attenuated. In contrast to the effects of PEG-rHuMGDF, a single injection of recombinant human granulocyte colony-stimulating factor (rhG-CSF) 1 hour after irradiation exclusively accelerated WBC recovery, but only to a similar extent as PEG-rHuMGDF (80 microg/kg) treatment even when rhG-CSF doses were escalated to 1,000 microg/kg. This appeared related to different pharmacokinetics of these two factors after a single injection in irradiated mice. The concentrations of PEG-rHuMGDF after injection persisted in the plasma for a longer time compared with rhG-CSF. These results indicate that a single injection of PEG-rHuMGDF at an early time after irradiation is able to effectively improve thrombocytopenia, anemia, and leukopenia with concomitant accelerated recovery of both primitive and committed hematopoietic progenitors in irradiated mice. Our data also show that compared with the rhG-CSF shown to exert multilineage effects on hematopoiesis, PEG-rHuMGDF has more wide-ranging effects on peripheral blood cell recovery.

  19. Diffuse chorioretinal atrophy after a single standard low- dose intravitreal melphalan injection in a child with retinoblastoma: a case report.

    PubMed

    Chao, An- Ning; Kao, Ling-Yuh; Liu, Laura; Wang, Nan-Kai

    2016-03-15

    Controlling retinoblastoma with seeding is challenging despite advances in treatment modalities. Intravitreal melphalan is an alternative to external beam radiation or enucleation for recurrent or refractory vitreous seeds. Significant ocular side effects following intravitreal melphalan injections are uncommon. Complications have been reported in eyes receiving higher concentrations of melphalan and repetitive injections. We report a case in which diffuse chorioretinal atrophy was developed at the injection site after a single, standard low-dose intravitreal melphalan injection. A 12-month-old female child without a family history of retinoblastoma presented with unilateral group C retinoblastoma in her right eye. A solitary tumour with retinal breaks on the tumour surface, and vitreous seeds overlying the tumour were observed at the 8 o'clock position of the retina. After two cycles of intra-arterial chemotherapy with melphalan, the main tumour displayed significant regression, but the vitreous seeds overlying the main tumour were still active. Because of the persistence of vitreous seeds and the inadequate response to intra-arterial melphalan treatment, intravitreal melphalan (8 μg in 0.05 mL) was injected using a 32-gauge needle 2.5 mm from the 5 o'clock position of the limbus, the meridian opposite to the vitreous seeds. After 1 month, the retina around the injection site demonstrated diffuse retinal pigment epithelium alterations with dense hard exudates. Although the main retinal mass, and vitreous seeds resolved, the hard exudates persisted for more than 2 years after the single low-dose melphalan injection. Intravitreal melphalan injections should be cautiously used for eyes with refractory seeds, particularly when multiple injections are required to control retinoblastoma seeds. Dose- related retinal toxicity could occur in pre-treated eyes even when a relatively low standard dose is used. Such patients should be followed up closely to monitor the treatment response and to assess potential delayed toxicity.

  20. Single-dose Intramuscular-injection Toxicology Test of Water-soluble Carthami-flos and Cervi cornu parvum Pharmacopuncture in a Rat Model.

    PubMed

    Park, Sunju; Sun, Seung-Ho

    2015-09-01

    The aim of the study is to investigate both the single-dose intramuscular injection toxicity and the approximate lethal dose of water-soluble Carthami-flos and Cervi cornu parvum pharmacopuncture (WCFC) in male and female Sprague-Dawley (SD) rats. The study was conducted at Biotoxtech Co. according to the Good Laboratory Practice (GLP) regulation and the toxicity test guidelines of the Ministry of Food and Drug Safety (MFDS) after approval of the Institutional Animal Care and Use Committee. Dosages for the control, high dose, middle dose and low dose groups were 0.5 mL/animal of saline and 0.5, 0.25 and 0.125 mL/animal of WCFC, respectively. WCFC was injected into the muscle of the left femoral region by using a disposable syringe (1 mL, 26 gauge). The general symptoms and mortality were observed 30 minutes, 1, 2, 4, and 6 hours after the first injection and then daily for 14 days after the injection. The body weights of the SD rats were measured on the day of the injection (before injection) and on the third, seventh, and fourteenth days after the injection. Serum biochemical and hematologic tests, necropsy examinations, and histopathologic examinations at the injection site were performed after the observation period. No deaths, abnormal clinical symptoms, or significant weight changes were observed in either male or female SD rats in the control or the test (0.125, 0.25, and 0.5 mL/animal) groups during the observation period. No significant differences in hematology and serum biochemistry and no macroscopic abnormalities at necropsy were found. No abnormal reactions at injection sites were noted on the topical tolerance tests. The results of this single-dose toxicity study show that WCFC is safe, its lethal doses in male and female SD rats being estimated to be higher than 0.5 mL/animal.

  1. De Quervain tendinopathy: survivorship and prognostic indicators of recurrence following a single corticosteroid injection.

    PubMed

    Earp, Brandon E; Han, Carin H; Floyd, W Emerson; Rozental, Tamara D; Blazar, Philip E

    2015-06-01

    To determine short- and long-term success rates of a single corticosteroid injection for de Quervain tendinopathy while identifying prognostic indicators for symptom recurrence and repeat intervention. Fifty consecutive patients with de Quervain tendinopathy treated with corticosteroid injections (lidocaine plus triamcinolone acetonide or dexamethasone) were prospectively enrolled. Patients with inflammatory arthritis, carpometacarpal osteoarthritis, or a previous distal radius fracture affecting the symptomatic wrist were excluded. Demographic data and information on existing comorbidities were recorded. Patients were seen in clinic at 6 weeks after injection and contacted at 3, 6, 9, and 12 months following injection to determine symptom recurrence and further intervention. Medical records were also reviewed for this purpose. Kaplan-Meier survival analysis and Cox regression modeling were used to estimate recurrence rates and identify predictors of symptom recurrence and repeat intervention. Fifty wrists in 50 patients (average age, 49 y) were included. One patient was lost to follow-up. Eighty-two percent of patients had resolved symptoms 6 weeks after a steroid injection. Twenty-four patients had a recurrence of symptoms at a median of 84 days after the injection. Eleven patients underwent additional intervention (7 surgical releases and 4 repeat injections) at a median of 129 days (range, 42-365) after the injection. Estimated freedom from symptom recurrence was 52% at 6 and 12 months. Estimated freedom from repeat intervention was 81% at 6 months and 77% at 12 months. Two of 3 patients with a history of trigger finger required subsequent de Quervain surgery. We demonstrated that a single cortisone injection was effective in alleviating symptoms of de Quervain tendinopathy in 82% of patients and that over half remained symptom-free for at least 12 months. All patients with recurring symptoms developed them within the first 6 months. Prognostic IV. Copyright © 2015 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  2. Data on subsurface storage of liquid waste near Pensacola, Florida, 1963-1980

    USGS Publications Warehouse

    Hull, R.W.; Martin, J.B.

    1982-01-01

    Since 1963, when industrial waste was first injected into the subsurface in northwest Florida, considerable data have been collected relating to the geochemistry of subsurface waste storage. This report presents hydrogeologic data on two subsurface waste storage. This report presents hydrogeologic data on two subsurface storage systems near Pensacola, Fla., which inject liquid industrial waste through deep wells into a saline aquifer. Injection sites are described giving a history of well construction, injection, and testing; geologic data from cores and grab samples; hydrographs of injection rates, volume, pressure, and water levels; and chemical and physical data from water-quality samples collected from injection and monitor wells. (USGS)

  3. Automated thermometric enzyme immunoassay of human proinsulin produced by Escherichia coli.

    PubMed

    Birnbaum, S; Bülow, L; Hardy, K; Danielsson, B; Mosbach, K

    1986-10-01

    We have determined and monitored the production and release of human proinsulin by genetically engineered Escherichia coli cells. Several M9 media samples were analyzed sequentially after centrifugation with the aid of a rapid automated flow-through thermometric enzyme-linked immunosorbent assay (TELISA) system. The response time was 7 min after sample injection and a single assay was complete after 13 min. Insulin concentrations in the range of 0.1-50 micrograms/ml could be determined. The TELISA method correlated well with conventional radioimmunoassay determinations. Standard curves were reproducible over a period of several days even when the immobilized antibody column was stored at 25 degrees C in the enzyme thermistor unit. Thus, immediate assay start up was possible.

  4. Single Event Analysis and Fault Injection Techniques Targeting Complex Designs Implemented in Xilinx-Virtex Family Field Programmable Gate Array (FPGA) Devices

    NASA Technical Reports Server (NTRS)

    Berg, Melanie D.; LaBel, Kenneth; Kim, Hak

    2014-01-01

    An informative session regarding SRAM FPGA basics. Presenting a framework for fault injection techniques applied to Xilinx Field Programmable Gate Arrays (FPGAs). Introduce an overlooked time component that illustrates fault injection is impractical for most real designs as a stand-alone characterization tool. Demonstrate procedures that benefit from fault injection error analysis.

  5. Stability of penicillin G sodium diluted with 0.9% sodium chloride injection or 5% dextrose injection and stored in polyvinyl chloride bag containers and elastomeric pump containers.

    PubMed

    Hossain, Mirza Akram; Friciu, Mihaela; Aubin, Sebastien; Leclair, Grégoire

    2014-04-15

    The stability of penicillin G sodium solutions stored in polyvinyl chloride (PVC) bags or elastomeric pump containers was studied. Test samples were prepared by diluting powdered penicillin G sodium (10 million units/10-mL vial) to solutions of 2,500 or 50,000 units/mL with 0.9% sodium chloride injection or 5% dextrose injection. The preparations were transferred to 250-mL PVC bags and elastomeric pump containers. All samples were prepared in triplicate and stored at 5°C. Chemical stability was measured by a stability-indicating high-performance liquid chromatographic (HPLC) assay and by pH evaluation. Particulate matter was evaluated according to compendial standards using a light-obscuration particle count test. Preparations were visually examined throughout the study. After 21 days of storage, all test samples remained chemically stable, with an HPLC assay recovery value of more than 90% of the initial value. After 28 days, all samples prepared with either diluent and stored in PVC bags, as well as the samples diluted to 2,500 units/mL with sodium chloride injection and stored in elastomeric pump containers, did not meet the recovery acceptance limit. For all test samples, the mean pH consistently decreased during storage, from about 6.4 to about 5.5. Particle counts remained acceptable throughout the study, and no change in appearance was observed. Penicillin G for injection (2,500 and 50,000 units/mL) diluted in 0.9% sodium chloride injection or 5% dextrose injection and stored at 5°C in PVC containers or elastomeric pump containers was physically and chemically stable for a period of at least 21 days.

  6. Enhancing resolution of free-flow zone electrophoresis via a simple sheath-flow sample injection.

    PubMed

    Yang, Ying; Kong, Fan-Zhi; Liu, Ji; Li, Jun-Min; Liu, Xiao-Ping; Li, Guo-Qing; Wang, Ju-Fang; Xiao, Hua; Fan, Liu-Yin; Cao, Cheng-Xi; Li, Shan

    2016-07-01

    In this work, a simple and novel sheath-flow sample injection method (SFSIM) is introduced to reduce the band broadening of free-flow zone electrophoresis separation in newly developed self-balance free-flow electrophoresis instrument. A needle injector was placed in the center of the separation inlet, into which the BGE and sample solution were pumped simultaneously. BGE formed sheath flow outside the sample stream, resulting in less band broadening related to hydrodynamics and electrodynamics. Hemoglobin and C-phycocyanin were successfully separated by the proposed method in contrast to the poor separation of free-flow electrophoresis with the traditional injection method without sheath flow. About 3.75 times resolution enhancement could be achieved by sheath-flow sample injection method. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Determination of octylphenol and nonylphenol in aqueous sample using simultaneous derivatization and dispersive liquid-liquid microextraction followed by gas chromatography-mass spectrometry.

    PubMed

    Luo, Shusheng; Fang, Ling; Wang, Xiaowei; Liu, Hongtao; Ouyang, Gangfeng; Lan, Chongyu; Luan, Tiangang

    2010-10-22

    A simple and fast sample preparation method for the determination of nonylphenol (NP) and octylphenol (OP) in aqueous samples by simultaneous derivatization and dispersive liquid-liquid microextraction (DLLME) was investigated using gas chromatography-mass spectrometry (GC/MS). In this method, a combined dispersant/derivatization catalyst (methanol/pyridine mixture) was firstly added to an aqueous sample, following which a derivatization reagent/extraction solvent (methyl chloroformate/chloroform) was rapidly injected to combine in situ derivatization and extraction in a single step. After centrifuging, the sedimented phase containing the analytes was injected into the GC port by autosampler for analysis. Several parameters, such as extraction solvent, dispersant solvent, amount of derivatization reagent, derivatization and extraction time, pH, and ionic strength were optimized to obtain higher sensitivity for the detection of NP and OP. Under the optimized conditions, good linearity was observed in the range of 0.1-1000 μg L⁻¹ and 0.01-100 μg L⁻¹ with the limits of detection (LOD) of 0.03 μg L⁻¹ and 0.002 μg L⁻¹ for NP and OP, respectively. Water samples collected from the Pearl River were analyzed with the proposed method, the concentrations of NP and OP were found to be 2.40 ± 0.16 μg L⁻¹ and 0.037 ± 0.001 μg L⁻¹, respectively. The relative recoveries of the water samples spiked with different concentrations of NP and OP were in the range of 88.3-106.7%. Compared with SPME and SPE, the proposed method can be successfully applied to the rapid and convenient determination of NP and OP in aqueous samples. Copyright © 2010 Elsevier B.V. All rights reserved.

  8. Modelling of Pesticide Transport During An Injection Experiment In A Physical and Geochemical Heterogeneous Aquifer

    NASA Astrophysics Data System (ADS)

    Hojberg, A. L.; Engesgaard, P.; Bjerg, P. L.

    The fate of selected pesticides under natural groundwater conditions was studied by natural gradient short and long term injection experiments in a shallow uncon- fined aerobic aquifer. Bentazone, DNOC, MCPP, dichlorprop, isoproturon, and BAM (dichlobenil metabolite) were injected in aqueous solution with bromide as a nonre- active tracer. The Bromide and pesticide plumes were sampled during the initial 25 m of migration in a dense monitoring net of multilevel samplers. The aquifer was physical and geochemical heterogeneous, which affected transport of several of the pesticides. A 3D reactive transport code was developed including one- and two-site linear/nonlinear equilibrium/nonequilibrium sorption and first-order as well as single Monod degradation kinetic coupled to microbial growth. Model simulations demon- strated that microbial growth was likely supported by the phenoxy acids MCPP and dichlorprop, while degradation of DNOC was adequately described by first-order degradation with no initial lag time. An observed vertical increase in pH was observed at the site and implemented in the transport code. The numerical analysis indicated that degradation of the three degradable pesticides may have been affected by vertical pH variations. Spatial variability in observed DNOC sorption was similarly suspected to be an effect of varying pH. pH dependency on DNOC sorption was confirmed by the model recognized by a match to observed breakthrough at the individual sampling points, when pH variation was included in the simulations.

  9. Dependence of injection locking of a TEA CO2 laser on intensity of injected radiation

    NASA Technical Reports Server (NTRS)

    Oppenheim, U. P.; Menzies, R. T.; Kavaya, M. J.

    1982-01-01

    The results of an experimental study to determine the minimum required injected power to control the output frequency of a TEA CO2 laser are reported. A CW CO2 waveguide laser was used as the injection oscillator. Both the power and the frequency of the injected radiation were varied, while the TEA resonator cavity length was adjusted to match the frequency of the injected signal. Single-longitudinal mode (SLM) TEA laser radiation was produced for injected power levels which are several orders of magnitude below those previously reported. The ratio of SLM output power to injection power exceeded 10 to the 12th at the lowest levels of injected intensity.

  10. Passive injection control for microfluidic systems

    DOEpatents

    Paul, Phillip H.; Arnold, Don W.; Neyer, David W.

    2004-12-21

    Apparatus for eliminating siphoning, "dead" regions, and fluid concentration gradients in microscale analytical devices. In its most basic embodiment, the present invention affords passive injection control for both electric field-driven and pressure-driven systems by providing additional fluid flow channels or auxiliary channels disposed on either side of a sample separation column. The auxiliary channels are sized such that volumetric fluid flow rate through these channels, while sufficient to move the sample away from the sample injection region in a timely fashion, is less than that through the sample separation channel or chromatograph.

  11. Pneumatic Microvalve-Based Hydrodynamic Sample Injection for High-Throughput, Quantitative Zone Electrophoresis in Capillaries

    PubMed Central

    2015-01-01

    A hybrid microchip/capillary electrophoresis (CE) system was developed to allow unbiased and lossless sample loading and high-throughput repeated injections. This new hybrid CE system consists of a poly(dimethylsiloxane) (PDMS) microchip sample injector featuring a pneumatic microvalve that separates a sample introduction channel from a short sample loading channel, and a fused-silica capillary separation column that connects seamlessly to the sample loading channel. The sample introduction channel is pressurized such that when the pneumatic microvalve opens briefly, a variable-volume sample plug is introduced into the loading channel. A high voltage for CE separation is continuously applied across the loading channel and the fused-silica capillary separation column. Analytes are rapidly separated in the fused-silica capillary, and following separation, high-sensitivity MS detection is accomplished via a sheathless CE/ESI-MS interface. The performance evaluation of the complete CE/ESI-MS platform demonstrated that reproducible sample injection with well controlled sample plug volumes could be achieved by using the PDMS microchip injector. The absence of band broadening from microchip to capillary indicated a minimum dead volume at the junction. The capabilities of the new CE/ESI-MS platform in performing high-throughput and quantitative sample analyses were demonstrated by the repeated sample injection without interrupting an ongoing separation and a linear dependence of the total analyte ion abundance on the sample plug volume using a mixture of peptide standards. The separation efficiency of the new platform was also evaluated systematically at different sample injection times, flow rates, and CE separation voltages. PMID:24865952

  12. Pneumatic Microvalve-Based Hydrodynamic Sample Injection for High-Throughput, Quantitative Zone Electrophoresis in Capillaries

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kelly, Ryan T.; Wang, Chenchen; Rausch, Sarah J.

    2014-07-01

    A hybrid microchip/capillary CE system was developed to allow unbiased and lossless sample loading and high throughput repeated injections. This new hybrid CE system consists of a polydimethylsiloxane (PDMS) microchip sample injector featuring a pneumatic microvalve that separates a sample introduction channel from a short sample loading channel and a fused silica capillary separation column that connects seamlessly to the sample loading channel. The sample introduction channel is pressurized such that when the pneumatic microvalve opens briefly, a variable-volume sample plug is introduced into the loading channel. A high voltage for CE separation is continuously applied across the loading channelmore » and the fused silica capillary separation column. Analytes are rapidly separated in the fused silica capillary with high resolution. High sensitivity MS detection after CE separation is accomplished via a sheathless CE/ESI-MS interface. The performance evaluation of the complete CE/ESI-MS platform demonstrated that reproducible sample injection with well controlled sample plug volumes could be achieved by using the PDMS microchip injector. The absence of band broadening from microchip to capillary indicated a minimum dead volume at the junction. The capabilities of the new CE/ESI-MS platform in performing high throughput and quantitative sample analyses were demonstrated by the repeated sample injection without interrupting an ongoing separation and a good linear dependence of the total analyte ion abundance on the sample plug volume using a mixture of peptide standards. The separation efficiency of the new platform was also evaluated systematically at different sample injection times, flow rates and CE separation voltages.« less

  13. Sustained neuroprotection from a single intravitreal injection of PGJ2 in a rodent model of anterior ischemic optic neuropathy.

    PubMed

    Touitou, Valerie; Johnson, Mary A; Guo, Yan; Miller, Neil R; Bernstein, Steven L

    2013-11-11

    Nonarteritic anterior ischemic optic neuropathy (NAION) is the most common cause of sudden optic nerve-related vision loss in persons older than 50 in the United States. There currently is no treatment for this disorder. We previously showed that systemic administration of 15-deoxy, delta (12, 14) prostaglandin J2 (PGJ2) is neuroprotective in our rodent model of AION (rAION). In this study, we determined if a single intravitreal (IVT) injection of PGJ2 is neuroprotective after rAION, and if this method of administration is toxic to the retina, optic nerve, or both. TOXICITY was assessed after a single IVT injection of PGJ2 in one eye and PBS in the contralateral eye of normal, adult Long-Evans rats. EFFICACY was assessed by inducing rAION in one eye and injecting either PGJ2 or vehicle immediately following induction, with the fellow eye serving as naïve control. Visual evoked potentials (VEPs) and ERGs were performed before induction and at specific intervals thereafter. Animals were euthanized 30 days after induction, after which immunohistochemistry, transmission electron microscopy, and quantitative stereology of retinal ganglion cell (RGC) numbers were performed. IVT PGJ2 did not alter the VEP or ERG compared with PBS-injected control eyes, and neither IVT PGJ2 nor PBS reduced overall RGC numbers. IVT PGJ2 preserved VEP amplitude, reduced optic nerve edema, and resulted in significant preservation of RGCs and axons in eyes with rAION. A single IVT injection of PGJ2 is nontoxic to the retina and optic nerve and neuroprotective when given immediately after rAION induction.

  14. Fibrosarcomas at presumed sites of injection in dogs: characteristics and comparison with non-vaccination site fibrosarcomas and feline post-vaccinal fibrosarcomas.

    PubMed

    Vascellari, M; Melchiotti, E; Bozza, M A; Mutinelli, F

    2003-08-01

    Fifteen fibrosarcomas, surgically excised from presumed sites of injection in dogs, and 10 canine fibrosarcomas excised from sites not used for injection were histologically and immunohistochemically compared with 20 feline post-vaccinal fibrosarcomas. Canine fibrosarcomas from presumed injection sites were of grade I (3), of grade II (4) and grade III (8). Two fibrosarcomas from non-injection sites were of grade I, four of grade II and four of grade III. Feline samples were classified as grade I (2), grade II (4) and grade III (14). All fibrosarcomas from presumed injection sites of both species showed lymphocytic inflammatory infiltration located at the tumour periphery, while two canine fibrosarcomas from non-injection sites showed perivascular inflammatory infiltration within the neoplasm. All samples were immunohistochemically examined for vimentin, smooth muscle actin, muscle specific actin and desmin expression. All tumours were positive for vimentin. Ten canine fibrosarcomas from presumed injection sites and all feline samples contained cells consistent with a myofibroblastic immunophenotype. Aluminium deposits were detected in eight canine fibrosarcomas from presumed injection sites and 11 feline post-vaccinal fibrosarcomas by the aurintricarboxylic acid method. The present study identifies distinct similarities between canine fibrosarcomas from presumed injection sites and feline post-vaccinal fibrosarcomas, suggesting the possibility of the development of post-injection sarcomas not only in cats, but also in dogs.

  15. Determination of Aristolochic Acid in Botanicals and Dietary Supplements by Liquid Chromatography with Ultraviolet Detection and by Liquid Chromatography/Mass Spectrometry: Single Laboratory Validation Confirmation

    PubMed Central

    Trujillo, William A.; Sorenson, Wendy R.; La Luzerne, Paul; Austad, John W.; Sullivan, Darryl

    2008-01-01

    The presence of aristolochic acid in some dietary supplements is a concern to regulators and consumers. A method has been developed, by initially using a reference method as a guide, during single laboratory validation (SLV) for the determination of aristolochic acid I, also known as aristolochic acid A, in botanical species and dietary supplements at concentrations of approximately 2 to 32 μg/g. Higher levels were determined by dilution to fit the standard curve. Through the SLV, the method was optimized for quantification by liquid Chromatography with ultraviolet detection (LC-UV) and LC/mass Spectrometry (MS) confirmation. The test samples were extracted with organic solvent and water, then injected on a reverse phase LC column. Quantification was achieved with linear regression using a laboratory automation system. The SLV study included systematically optimizing the LC-UV method with regard to test sample size, fine grinding of solids, and solvent extraction efficiency. These parameters were varied in increments (and in separate optimization studies), in order to ensure that each parameter was individually studied; the test results include corresponding tables of parameter variations. In addition, the chromatographic conditions were optimized with respect to injection volume and detection wavelength. Precision studies produced overall relative standard deviation values from 2.44 up to 8.26% for aristolochic acid I. Mean recoveries were between 100 and 103% at the 2 μg/g level, between 102 and 103% at the 10 μg/g level, and 104% at the 30 μg/g level. PMID:16915829

  16. Determination of aristolochic acid in botanicals and dietary supplements by liquid chromatography with ultraviolet detection and by liquid chromatography/mass spectrometry: single laboratory validation confirmation.

    PubMed

    Trujillo, William A; Sorenson, Wendy R; La Luzerne, Paul; Austad, John W; Sullivan, Darryl

    2006-01-01

    The presence of aristolochic acid in some dietary supplements is a concern to regulators and consumers. A method has been developed, by initially using a reference method as a guide, during single laboratory validation (SLV) for the determination of aristolochic acid I, also known as aristolochic acid A, in botanical species and dietary supplements at concentrations of approximately 2 to 32 microg/g. Higher levels were determined by dilution to fit the standard curve. Through the SLV, the method was optimized for quantification by liquid chromatography with ultraviolet detection (LC-UV) and LC/mass spectrometry (MS) confirmation. The test samples were extracted with organic solvent and water, then injected on a reverse phase LC column. Quantification was achieved with linear regression using a laboratory automation system. The SLV study included systematically optimizing the LC-UV method with regard to test sample size, fine grinding of solids, and solvent extraction efficiency. These parameters were varied in increments (and in separate optimization studies), in order to ensure that each parameter was individually studied; the test results include corresponding tables of parameter variations. In addition, the chromatographic conditions were optimized with respect to injection volume and detection wavelength. Precision studies produced overall relative standard deviation values from 2.44 up to 8.26% for aristolochic acid I. Mean recoveries were between 100 and 103% at the 2 microg/g level, between 102 and 103% at the 10 microg/g level, and 104% at the 30 microg/g level.

  17. Efficacy of a Single Dose of Basic Fibroblast Growth Factor: Clinical Observation for 1 Year.

    PubMed

    Suzuki, Hirotaka; Makiyama, Kiyoshi; Hirai, Ryoji; Matsuzaki, Hiroumi; Furusaka, Toru; Oshima, Takeshi

    2016-11-01

    Basic fibroblast growth factor promotes wound healing by accelerating healthy granulation and epithelialization. However, the duration of the effects of a single intracordal injection of basic fibroblast growth factor has not been established, and administration intervals and timing have yet to be standardized. Here, we administered a single injection to patients with insufficient glottic closure and conducted follow-up examinations with high-speed digital imaging to determine the duration of the treatment response. Case series. For treatment, 20 µg/mL recombinant human basic fibroblast growth factor was injected into two vocal cords. The following examinations were performed before the procedure and at 3-month intervals for 12 months starting at 1 month postinjection: Grade, Roughness, Breathiness, Asthenia, and Strain (GRBAS) scale assessment, maximum phonation time, acoustic analysis, high-speed digital imaging, glottal wave analysis, and kymographic analysis. Postinjection, the GRBAS scale score decreased, and the maximum phonation time was prolonged. In addition, the mean minimum glottal area and mean minimum glottal distance decreased. These changes were significant at 12 months postinjection compared with preinjection. However, there were no significant changes in the vibrations of the vocal cord margins. The intracordal injection of basic fibroblast growth factor improved insufficient glottic closure without reducing the vibrations of the vocal cord margins. This effect remained evident at 12 months postinjection. A single injection can be expected to yield a sufficient and persistent long-term effect. Copyright © 2016 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  18. Long term effects of lipopolysaccharide on satellite glial cells in mouse dorsal root ganglia

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Blum, E.; Procacci, P.; Conte, V.

    Lipopolysaccharide (LPS) has been used extensively to study neuroinflammation, but usually its effects were examined acutely (24 h<). We have shown previously that a single intraperitoneal LPS injection activated satellite glial cells (SGCs) in mouse dorsal root ganglia (DRG) and altered several functional parameters in these cells for at least one week. Here we asked whether the LPS effects would persist for 1 month. We injected mice with a single LPS dose and tested pain behavior, assessed SGCs activation in DRG using glial fibrillary acidic protein (GFAP) immunostaining, and injected a fluorescent dye intracellularly to study intercellular coupling. Electron microscopymore » was used to quantitate changes in gap junctions. We found that at 30 days post-LPS the threshold to mechanical stimulation was lower than in controls. GFAP expression, as well as the magnitude of dye coupling among SGCs were greater than in controls. Electron microscopy analysis supported these results, showing a greater number of gap junctions and an abnormal growth of SGC processes. These changes were significant, but less prominent than at 7 days post-LPS. We conclude that a single LPS injection exerts long-term behavioral and cellular changes. The results are consistent with the idea that SGC activation contributes to hyperalgesia. - Highlights: • A single lipopolysaccharides injection activated glia in mouse dorsal root ganglia for 30 days. • This was accompanied by increased communications by gap junctions among glia and by hyperalgesia. • Glial activation and coupling may contribute to chronic pain.« less

  19. Rapid assessment of injection practices in Cambodia, 2002

    PubMed Central

    Vong, Sirenda; Perz, Joseph F; Sok, Srun; Som, Seiharath; Goldstein, Susan; Hutin, Yvan; Tulloch, James

    2005-01-01

    Background Injection overuse and unsafe injection practices facilitate transmission of bloodborne pathogens such as hepatitis B virus (HBV), hepatitis C virus (HCV), and human immunodeficiency virus (HIV). Anecdotal reports of unsafe and unnecessary therapeutic injections and the high prevalence of HBV (8.0%), HCV (6.5%), and HIV (2.6%) infection in Cambodia have raised concern over injection safety. To estimate the magnitude and patterns of such practices, a rapid assessment of injection practices was conducted. Methods We surveyed a random sample of the general population in Takeo Province and convenience samples of prescribers and injection providers in Takeo Province and Phnom Penh city regarding injection-related knowledge, attitudes, and practices. Injection providers were observed administering injections. Data were collected using standardized methods adapted from the World Health Organization safe injection assessment guidelines. Results Among the general population sample (n = 500), the overall injection rate was 5.9 injections per person-year, with 40% of participants reporting receipt of ≥ 1 injection during the previous 6 months. Therapeutic injections, intravenous infusions, and immunizations accounted for 74%, 16% and 10% of injections, respectively. The majority (>85%) of injections were received in the private sector. All participants who recalled their last injection reported the injection was administered with a newly opened disposable syringe and needle. Prescribers (n = 60) reported that 47% of the total prescriptions they wrote included a therapeutic injection or infusion. Among injection providers (n = 60), 58% recapped the syringe after use and 13% did not dispose of the used needle and syringe appropriately. Over half (53%) of the providers reported a needlestick injury during the previous 12 months. Ninety percent of prescribers and injection providers were aware HBV, HCV, and HIV were transmitted through unsafe injection practices. Knowledge of HIV transmission through "dirty" syringes among the general population was also high (95%). Conclusion Our data suggest that Cambodia has one of the world's highest rates of overall injection usage, despite general awareness of associated infection risks. Although there was little evidence of reuse of needles and syringes, support is needed for interventions to address injection overuse, healthcare worker safety and appropriate waste disposal. PMID:15929800

  20. Safety and effectiveness of a single and repeat intramuscular injection of a GnRH vaccine (GonaCon™) in adult female domestic cats.

    PubMed

    Vansandt, L M; Kutzler, M A; Fischer, A E; Morris, K N; Swanson, W F

    2017-04-01

    Sterilization is a key strategy to reduce the number of domestic cats entering and killed in shelters each year. However, surgical sterilization is expensive and labour-intensive and cannot fully address the 70 million free-roaming cats estimated to exist in the United States. GonaCon™ is a gonadotropin-releasing hormone vaccine originally developed for use as a wildlife immunocontraceptive. An earlier formulation was tested in domestic cats and found to be safe and effective for long-term contraception. However, the current Environmental Protection Agency (EPA)-registered formulation consists of a different antigen-carrier protein and increased antigen concentration and has never been tested in cats. A pilot study was undertaken to evaluate the short-term safety of a single GonaCon immunization, assess the consequences of vaccinated cats receiving an accidental second GonaCon injection and determine the humoral immune response to immunization. During Phase 1, cats in Group A (n = 3) received a single intramuscular injection of GonaCon and Group B (n = 3) received a single intramuscular injection of saline. During Phase 2, Group A received a second GonaCon injection and Group B received their initial GonaCon injection. All cats developed GnRH antibodies within 30 days of vaccine administration. The endpoint titre (1:1,024,000) was similar among all cats, and levels remained high throughout the duration of the study. Four cats developed a sterile, painless, self-limiting mass at the site of injection. The mean number of days to mass development was 110.3 (range, 18-249 days). In conclusion, this preliminary study suggests that the EPA-registered GonaCon formulation is safe for continued testing in domestic cats, an accidental revaccination should not increase the risk of a vaccine reaction and the EPA-registered formulation effectively elicits a strong humoral immune response. © 2016 Blackwell Verlag GmbH.

  1. Parametric study of injection rates with solenoid injectors in an injection quantity and rate measuring device

    DOE PAGES

    Busch, Stephen; Miles, Paul C.

    2015-03-31

    A Moehwald HDA (HDA is a German acronym: Hydraulischer Druckanstieg: hydraulic pressure increase) injection quantity and rate measuring unit is used to investigate injection rates obtained with a fast-acting, preproduction diesel solenoid injector. Experimental parametric variations are performed to determine their impact on measured injection rate traces. A pilot–main injection strategy is investigated for various dwell times; these preproduction injectors can operate with very short dwell times with distinct pilot and main injection events. Dwell influences the main injection rate shape. Furthermore, a comparison between a diesel-like fuel and a gasoline-like fuel shows that injection rates are comparable for amore » single injection but dramatically different for multiple injections with short dwells.« less

  2. A Simple Method to Measure Renal Function in Swine by the Plasma Clearance of Iohexol

    PubMed Central

    Luis-Lima, Sergio; García-Contreras, Consolación; Carrara, Fabiola; Negrín-Mena, Natalia; Jiménez-Sosa, Alejandro; Jiménez-Hernández, Hugo; Porrini, Esteban

    2018-01-01

    There is no simple method to measure glomerular filtration rate (GFR) in swine, an established model for studying renal disease. We developed a protocol to measure GFR in conscious swine by using the plasma clearance of iohexol. We used two groups, test and validation, with eight animals each. Ten milliliters of iohexol (6.47 g) was injected into the marginal auricular vein and blood samples (3 mL) were collected from the orbital sinus at different points after injection. GFR was determined using two models: two-compartment (CL2: all samples) and one-compartment (CL1: the last six samples). In the test group, CL1 overestimated CL2 by ~30%: CL2 = 245 ± 93 and CL1 = 308 ± 123 mL/min. This error was corrected by a first-order polynomial quadratic equation to CL1, which was considered the simplified method: SM = −47.909 + (1.176xCL1) − (0.00063968xCL12). The SM showed narrow limits of agreement with CL2, a concordance correlation of 0.97, and a total deviation index of 14.73%. Similar results were obtained for the validation group. This protocol is reliable, reproducible, can be performed in conscious animals, uses a single dose of the marker, and requires a reduced number of samples, and avoids urine collection. Finally, it presents a significant improvement in animal welfare conditions and handling necessities in experimental trials. PMID:29329247

  3. Toots, tastes and tester shots: user accounts of drug sampling methods for gauging heroin potency.

    PubMed

    Mars, Sarah G; Ondocsin, Jeff; Ciccarone, Daniel

    2018-05-16

    Internationally, overdose is the primary cause of death among people injecting drugs. However, since 2001, heroin-related overdose deaths in the United States (US) have risen sixfold, paralleled by a rise in the death rate attributed to synthetic opioids, particularly the fentanyls. This paper considers the adaptations some US heroin injectors are making to protect themselves from these risks. Between 2015 and 2016, a team of ethnographers collected data through semi-structured interviews and observation captured in field notes and video recording of heroin preparation/consumption. Ninety-one current heroin injectors were interviewed (Baltimore, n = 22; Chicago, n = 24; Massachusetts and New Hampshire, n = 36; San Francisco, n = 9). Experience injecting heroin ranged from < 1-47 years. Eight participants, who were exclusively heroin snorters, were also interviewed. Data were analyzed thematically. Across the study sites, multiple methods of sampling "heroin" were identified, sometimes used in combination, ranging from non-injecting routes (snorting, smoking or tasting a small amount prior to injection) to injecting a partial dose and waiting. Partial injection took different forms: a "slow shot" where the user injected a portion of the solution in the syringe, keeping the needle in the injection site, and continuing or withdrawing the syringe or a "tester shot" where the solution was divided into separate injections. Other techniques included getting feedback from others using heroin of the same batch or observing those with higher tolerance injecting heroin from the same batch before judging how much to inject themselves. Although a minority of those interviewed described using these drug sampling techniques, there is clearly receptivity among some users to protecting themselves by using a variety of methods. The use of drug sampling as a means of preventing an overdose from injection drug use reduces the quantity absorbed at any one time allowing users to monitor drug strength and titrate their dose accordingly. Given the highly unpredictable potency of the drugs currently being sold as heroin in the US, universal precautions should be adopted more widely. Further research is needed into facilitators and barriers to the uptake of these drug sampling methods.

  4. Terahertz light-emitting graphene-channel transistor toward single-mode lasing

    NASA Astrophysics Data System (ADS)

    Yadav, Deepika; Tamamushi, Gen; Watanabe, Takayuki; Mitsushio, Junki; Tobah, Youssef; Sugawara, Kenta; Dubinov, Alexander A.; Satou, Akira; Ryzhii, Maxim; Ryzhii, Victor; Otsuji, Taiichi

    2018-03-01

    A distributed feedback dual-gate graphene-channel field-effect transistor (DFB-DG-GFET) was fabricated as a current-injection terahertz (THz) light-emitting laser transistor. We observed a broadband emission in a 1-7.6-THz range with a maximum radiation power of 10 μW as well as a single-mode emission at 5.2 THz with a radiation power of 0.1 μW both at 100 K when the carrier injection stays between the lower cutoff and upper cutoff threshold levels. The device also exhibited peculiar nonlinear threshold-like behavior with respect to the current-injection level. The LED-like broadband emission is interpreted as an amplified spontaneous THz emission being transcended to a single-mode lasing. Design constraints on waveguide structures for better THz photon field confinement with higher gain overlapping as well as DFB cavity structures with higher Q factors are also addressed towards intense, single-mode continuous wave THz lasing at room temperature.

  5. Locally limited inhibition of bone resorption and orthodontic relapse by recombinant osteoprotegerin protein.

    PubMed

    Schneider, D A; Smith, S M; Campbell, C; Hayami, T; Kapila, S; Hatch, N E

    2015-04-01

    To determine minimal dose levels required for local inhibition of orthodontic relapse by recombinant OPG protein (OPG-Fc), while also determining effects of injected OPG-Fc on alveolar bone and long bone. The Department of Orthodontics and Pediatric Dentistry at the University of Michigan. Eighteen male Sprague Dawley rats. Maxillary molars were moved with nickel-titanium springs and then allowed to relapse in Sprague Dawley rats. Upon appliance removal, animals were injected with a single dose of 1.0 mg/kg OPG-Fc, 0.1 mg/kg OPG-Fc, or phosphate-buffered saline (vehicle) just distal to the molar teeth. Tooth movement measurements were made from stone casts, which were scanned and digitally measured. Alveolar tissues were examined by histology. Micro-computed tomography was used to quantify changes in alveolar and femur bone. Local injection of OPG-Fc inhibited molar but not incisor relapse, when compared to vehicle-injected animals. No significant differences in alveolar or femur bone were seen between the three treatment groups after 24 days of relapse. Our results demonstrate that a single local injection of OPG-Fc effectively inhibits orthodontic relapse, with minimal systemic bone metabolic effects. Our results also show that a single injection of OPG-Fc will influence tooth movement only in teeth close to the injection site. These findings indicate that OPG-Fc has potential as a safe and effective pharmacological means to locally control osteoclasts, for uses such as maintaining anchorage during orthodontic tooth movement and preventing orthodontic relapse in humans. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  6. Contraction produced by intracellular injection of calcium, strontium, and barium in the single crayfish muscle fibers.

    PubMed

    Matsumura, M; Mashima, H

    1976-01-01

    Ca ions were ionophoretically injected through an intracellular microelectrode into the single muscle fiber of a crayfish, and the resulting contraction sphere was observed under a microscope and photographed with a movie camera. The minimum contraction produced by the threshold current involved usually three or four, sometimes two, sarcomers on both sides of the injecting pipette but contraction involving only one sarcomere was not observered. The rheobase of the Ca-injecting current was 3.2 X 10(-9) A. The strength-duration curves were determined for Ca-, Sr-, and Ba-injecting currents; all fitted a similar hyperbolic equation. The threshold amount of Ca above rheobasic injection was 2.1 X 10(-15)mol, and the ratios between threshold amounts were Ca: Sr: Ba=1: 1.9: 3.0. The effects of Ca and Sr were additive for the contraction. More current was required for the Ca-injection to produce the contraction in the K-depolarized-or 15mM-procaine-treated muscle, although less current was sufficient for the muscle treated with 0.5-1.0 mM of caffeine. The participation of the Ca-induced Ca release mechanism in the contraction produced by Ca injection and the role of Sr or Ba as a substitute for Ca were discussed.

  7. Administering Multiple Injectable Vaccines During a Single Visit-Summary of Findings From the Accelerated Introduction of Inactivated Polio Vaccine Globally.

    PubMed

    Dolan, Samantha B; Patel, Manish; Hampton, Lee M; Burnett, Eleanor; Ehlman, Daniel C; Garon, Julie; Cloessner, Emily; Chmielewski, Elizabeth; Hyde, Terri B; Mantel, Carsten; Wallace, Aaron S

    2017-07-01

    In 2013, the World Health Organization's (WHO's) Strategic Advisory Group of Experts (SAGE) recommended that all 126 countries using only oral polio vaccine (OPV) introduce at least 1 dose of inactivated polio vaccine (IPV) into their routine immunization schedules by the end of 2015. In many countries, the addition of IPV would necessitate delivery of multiple injectable vaccines (hereafter, "multiple injections") during a single visit, with infants receiving IPV alongside pentavalent vaccine (which covers diphtheria, tetanus, and whole-cell pertussis; hepatitis B; and Haemophilus influenzae type b) and pneumococcal vaccine. Unanticipated concerns emerged from countries over acceptability of multiple injections, sites of administration, and safety. We contextualized the issues surrounding multiple injections by documenting concerns associated with administration of ≥3 injections, existing evidence in the published literature, and findings of a systematic review on administration practices and techniques. Concerns associated with multiple-injection visits were documented from meetings and personal communications with immunization program managers. Published literature on the acceptability of multiple injections by providers and caregivers was summarized, and a systematic review of the literature on administration practices was completed on the following topics: spacing between injection sites (ie, vaccine spacing), site of injection, route of injection, and procedural preparedness. WHO and United Nations Children's Fund data from 2013-2015 were used to assess multiple-injection visits included in national immunization schedules. Healthcare provider and caregiver attitudes and practices indicated concerns about infant pain, potential adverse effects, and uncertainty about vaccine effectiveness with multiple-injection visits. Published literature reinforced the record of safety and acceptance of the recommended schedule of IPV by the SAGE, but the evidence was largely from developed countries. Parental acceptance of multiple injections was associated with a positive provider recommendation to the caregiver. Findings of the systematic review identified that the intramuscular route is preferred over the subcutaneous route for vaccine administration and that the vastus lateralis muscle is preferred over the deltoid muscle for intramuscular injections. Recommendations on vaccine spacing and procedural preparedness were based on practical necessities, but comparative evidence was not identified. During 2013-2015, 85 countries added IPV to their immunization schedules, 46 (55%) of which adopted a schedule resulting in 3 injectable vaccines being administered in a single visit. The multiple-injection experience identified gaps in guidance for future vaccine introductions. Global partner organizations quickly mobilized to assess, document, and communicate the existing global experience on multiple-injection visits. This evidence-based approach provided reassurance to opinion leaders, health workers, and professional societies, thus encouraging uptake of IPV as a second or third injection in an accelerated manner globally. © The Author 2017. Published by Oxford University Press for the Infectious Diseases Society of America.

  8. Simultaneous analysis of multiple classes of antimicrobials in environmental water samples using SPE coupled with UHPLC-ESI-MS/MS and isotope dilution.

    PubMed

    Tran, Ngoc Han; Chen, Hongjie; Do, Thanh Van; Reinhard, Martin; Ngo, Huu Hao; He, Yiliang; Gin, Karina Yew-Hoong

    2016-10-01

    A robust and sensitive analytical method was developed for the simultaneous analysis of 21 target antimicrobials in different environmental water samples. Both single SPE and tandem SPE cartridge systems were investigated to simultaneously extract multiple classes of antimicrobials. Experimental results showed that good extraction efficiencies (84.5-105.6%) were observed for the vast majority of the target analytes when extraction was performed using the tandem SPE cartridge (SB+HR-X) system under an extraction pH of 3.0. HPLC-MS/MS parameters were optimized for simultaneous analysis of all the target analytes in a single injection. Quantification of target antimicrobials in water samples was accomplished using 15 isotopically labeled internal standards (ILISs), which allowed the efficient compensation of the losses of target analytes during sample preparation and correction of matrix effects during UHPLC-MS/MS as well as instrument fluctuations in MS/MS signal intensity. Method quantification limit (MQL) for most target analytes based on SPE was below 5ng/L for surface waters, 10ng/L for treated wastewater effluents, and 15ng/L for raw wastewater. The method was successfully applied to detect and quantify the occurrence of the target analytes in raw influent, treated effluent and surface water samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Effects of large volume injection of aliphatic alcohols as sample diluents on the retention of low hydrophobic solutes in reversed-phase liquid chromatography.

    PubMed

    David, Victor; Galaon, Toma; Aboul-Enein, Hassan Y

    2014-01-03

    Recent studies showed that injection of large volume of hydrophobic solvents used as sample diluents could be applied in reversed-phase liquid chromatography (RP-LC). This study reports a systematic research focused on the influence of a series of aliphatic alcohols (from methanol to 1-octanol) on the retention process in RP-LC, when large volumes of sample are injected on the column. Several model analytes with low hydrophobic character were studied by RP-LC process, for mobile phases containing methanol or acetonitrile as organic modifiers in different proportions with aqueous component. It was found that starting with 1-butanol, the aliphatic alcohols can be used as sample solvents and they can be injected in high volumes, but they may influence the retention factor and peak shape of the dissolved solutes. The dependence of the retention factor of the studied analytes on the injection volume of these alcohols is linear, with a decrease of its value as the sample volume is increased. The retention process in case of injecting up to 200μL of upper alcohols is dependent also on the content of the organic modifier (methanol or acetonitrile) in mobile phase. Copyright © 2013 Elsevier B.V. All rights reserved.

  10. Thermal single-well injection-withdrawal tracer tests for determining fracture-matrix heat transfer area

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pruess, K.; Doughty, C.

    2010-01-15

    Single-well injection-withdrawal (SWIW) tracer tests involve injection of traced fluid and subsequent tracer recovery from the same well, usually with some quiescent time between the injection and withdrawal periods. SWIW are insensitive to variations in advective processes that arise from formation heterogeneities, because upon withdrawal, fluid parcels tend to retrace the paths taken during injection. However, SWIW are sensitive to diffusive processes, such as diffusive exchange of conservative or reactive solutes between fractures and rock matrix. This paper focuses on SWIW tests in which temperature itself is used as a tracer. Numerical simulations demonstrate the sensitivity of temperature returns tomore » fracture-matrix interaction. We consider thermal SWIW response to the two primary reservoir improvements targeted with stimulation, (1) making additional fractures accessible to injected fluids, and (2) increasing the aperture and permeability of pre-existing fractures. It is found that temperature returns in SWIW tests are insensitive to (2), while providing a strong signal of more rapid temperature recovery during the withdrawal phase for (1).« less

  11. The Pharmacokinetics of Enrofloxacin in Adult African Clawed Frogs (Xenopus laevis)

    PubMed Central

    Howard, Antwain M; Papich, Mark G; Felt, Stephen A; Long, Charles T; McKeon, Gabriel P; Bond, Emmitt S; Torreilles, Stéphanie L; Luong, Richard H; Green, Sherril L

    2010-01-01

    Pharmacokinetics of enrofloxacin, a fluoroquinolone antibiotic, was determined in adult female Xenopus laevis after single-dose administration (10 mg/kg) by intramuscular or subcutaneous injection. Frogs were evaluated at various time points until 8 h after injection. Plasma was analyzed for antibiotic concentration levels by HPLC. We computed pharmacokinetic parameters by using noncompartmental analysis of the pooled concentrations (naive pooled samples). After intramuscular administration of enrofloxacin, the half-life was 5.32 h, concentration maximum was 10.85 µg/mL, distribution volume was 841.96 mL/kg, and area under the time–concentration curve was 57.59 µg×h/mL; after subcutaneous administration these parameters were 4.08 h, 9.76 µg/mL, 915.85 mL/kg, and 47.42 µg×h/mL, respectively. According to plasma pharmacokinetics, Xenopus seem to metabolize enrofloxacin in a manner similar to mammals: low levels of the enrofloxacin metabolite, ciprofloxacin, were detected in the frogs’ habitat water and plasma. At necropsy, there were no gross or histologic signs of toxicity after single-dose administration; toxicity was not evaluated for repeated dosing. The plasma concentrations reached levels considered effective against common aquatic pathogens and suggest that a single, once-daily dose would be a reasonable regimen to consider when treating sick frogs. The treatment of sick frogs should be based on specific microbiologic identification of the pathogen and on antibiotic susceptibility testing. PMID:21205443

  12. Electrokinetic gated injection-based microfluidic system for quantitative analysis of hydrogen peroxide in individual HepG2 cells.

    PubMed

    Zhang, Xinyuan; Li, Qingling; Chen, Zhenzhen; Li, Hongmin; Xu, Kehua; Zhang, Lisheng; Tang, Bo

    2011-03-21

    A microfluidic system to determine hydrogen peroxide (H(2)O(2)) in individual HepG2 cells based on the electrokinetic gated injection was developed for the first time. A home-synthesized fluorescent probe, bis(p-methylbenzenesulfonate)dichlorofluorescein (FS), was employed to label intracellular H(2)O(2) in the intact cells. On a simple cross microchip, multiple single-cell operations, including single cell injection, cytolysis, electrophoresis separation and detection of H(2)O(2), were automatically carried out within 60 s using the electrokinetic gated injection and laser-induced fluorescence detection (LIFD). The performance of the method was evaluated under the optimal conditions. The linear calibration curve was over a range of 4.39-610 amol (R(2)=0.9994). The detection limit was 0.55 amol or 9.0×10(-10) M (S/N=3). The relative standard deviations (RSDs, n=6) of migration time and peak area were 1.4% and 4.8%, respectively. With the use of this method, the average content of H(2)O(2) in single HepG2 cells was found to be 16.09±9.84 amol (n=15). Separation efficiencies in excess of 17,000 theoretical plates for the cells were achieved. These results demonstrated that the efficient integration and automation of these single-cell operations enabled the sensitive, reproducible, and quantitative examination of intracellular H(2)O(2) at single-cell level. Owing to the advantages of simple microchip structure, controllable single-cell manipulation and ease in building, this platform provides a universal way to automatically determine other intracellular constituents within single cells. This journal is © The Royal Society of Chemistry 2011

  13. Hyaluronic Acid (HA)-Polyethylene glycol (PEG) as injectable hydrogel for intervertebral disc degeneration patients therapy

    NASA Astrophysics Data System (ADS)

    Putri Kwarta, Cityta; Widiyanti, Prihartini; Siswanto

    2017-05-01

    Chronic Low Back Pain (CLBP) is one health problem that is often encountered in a community. Inject-able hydrogels are the newest way to restore the disc thickness and hydration caused by disc degeneration by means of minimally invasive surgery. Thus, polymers can be combined to improve the characteristic properties of inject-able hydrogels, leading to use of Hyaluronic Acid (a natural polymer) and Polyethylene glycol (PEG) with Horse Radish Peroxide (HRP) cross linker enzymes. The swelling test results, which approaches were the ideal disc values, were sampled with variation of enzyme concentrations of 0.25 µmol/min/mL. The enzyme concentrations were 33.95%. The degradation test proved that the sample degradation increased along with the decrease of the HRP enzyme concentration. The results of the cytotoxicity assay with MTT assay method showed that all samples resulted in the 90% of living cells are not toxic. In vitro injection, models demonstrated that higher concentration of the enzymes was less state of gel which would rupture when released from the agarose gel. The functional group characterization shows the cross linking bonding in sample with enzyme adding. The conclusion of this study is PEG-HA-HRP enzyme are safe polymer composites which have a potential to be applied as an injectable hydrogel for intervertebral disc degeneration.

  14. Simulated fault injection - A methodology to evaluate fault tolerant microprocessor architectures

    NASA Technical Reports Server (NTRS)

    Choi, Gwan S.; Iyer, Ravishankar K.; Carreno, Victor A.

    1990-01-01

    A simulation-based fault-injection method for validating fault-tolerant microprocessor architectures is described. The approach uses mixed-mode simulation (electrical/logic analysis), and injects transient errors in run-time to assess the resulting fault impact. As an example, a fault-tolerant architecture which models the digital aspects of a dual-channel real-time jet-engine controller is used. The level of effectiveness of the dual configuration with respect to single and multiple transients is measured. The results indicate 100 percent coverage of single transients. Approximately 12 percent of the multiple transients affect both channels; none result in controller failure since two additional levels of redundancy exist.

  15. Spectral modification of the laser emission of a terahertz quantum cascade laser induced by broad-band double pulse injection seeding

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Markmann, Sergej, E-mail: sergej.markmann@ruhr-uni-bochum.de; Nong, Hanond, E-mail: nong.hanond@ruhr-uni-bochum.de; Hekmat, Negar

    2015-09-14

    We demonstrate by injection seeding that the spectral emission of a terahertz (THz) quantum cascade laser (QCL) can be modified with broad-band THz pulses whose bandwidths are greater than the QCL bandwidth. Two broad-band THz pulses delayed in time imprint a modulation on the single THz pulse spectrum. The resulting spectrum is used to injection seed the THz QCL. By varying the time delay between the THz pulses, the amplitude distribution of the QCL longitudinal modes is modified. By applying this approach, the QCL emission is reversibly switched from multi-mode to single mode emission.

  16. Efficient spin-current injection in single-molecule magnet junctions

    NASA Astrophysics Data System (ADS)

    Xie, Haiqing; Xu, Fuming; Jiao, Hujun; Wang, Qiang; Liang, J.-Q.

    2018-01-01

    We study theoretically spin transport through a single-molecule magnet (SMM) in the sequential and cotunneling regimes, where the SMM is weakly coupled to one ferromagnetic and one normal-metallic leads. By a master-equation approach, it is found that the spin polarization injected from the ferromagnetic lead is amplified and highly polarized spin-current can be generated, due to the exchange coupling between the transport electron and the anisotropic spin of the SMM. Moreover, the spin-current polarization can be tuned by the gate or bias voltage, and thus an efficient spin injection device based on the SMM is proposed in molecular spintronics.

  17. Injection chaining of diode-pumped single-frequency ring lasers for free-space communication

    NASA Technical Reports Server (NTRS)

    Cheng, E. A. P.; Kane, T. J.; Wallace, R. W.; Cornwell, D. M., Jr.

    1991-01-01

    A high-power three-stage laser suitable for use in a space communication system has been built. This laser uses three diode-pumped Nd:YAG oscillators coherently combined using the technique of injection chaining. All three oscillators are in one compact and permanently aligned package, and are actively frequency locked to provide CW single frequency output. The three stages provide the redundancy desirable for space communications.

  18. Characterizing SRAM Single Event Upset in Terms of Single and Double Node Charge Collection

    NASA Technical Reports Server (NTRS)

    Black, J. D.; Ball, D. R., II; Robinson, W. H.; Fleetwood, D. M.; Schrimpf, R. D.; Reed, R. A.; Black, D. A.; Warren, K. M.; Tipton, A. D.; Dodd, P. E.; hide

    2008-01-01

    A well-collapse source-injection mode for SRAM SEU is demonstrated through TCAD modeling. The recovery of the SRAM s state is shown to be based upon the resistive path from the p+-sources in the SRAM to the well. Multiple cell upset patterns for direct charge collection and the well-collapse source-injection mechanisms are then predicted and compared to recent SRAM test data.

  19. Sex steroid levels, oocyte maturation and spawning performance in Waigieu seaperch (Psammoperca waigiensis) exposed to thyroxin, human chorionic gonadotropin, luteinizing hormone releasing hormone and carp pituitary extract.

    PubMed

    Pham, Hung Quoc; Nguyen, Anh Tuong; Nguyen, Mao Dinh; Arukwe, Augustine

    2010-02-01

    In the present study, we have investigated the sex steroid hormone levels, oocyte maturation and spawning performance in Waigieu seaperch (Psammoperca waigiensis) exposed to different doses (0, (control), 0.05, 0.25 and 0.5 mg/kg fish) of thyroxin (T(4)) both through diet (continuously) and injection (single injection). In addition, we also studied plasma steroid hormone levels and spawning performances in female fish injected with a single dose of D-Ala(6), Pro(9)-Net-mGnRH (LHRHa: 50 microg/kg), human chronic gonadotropin (HCG: 1,500 IU/kg) and carp pituitary extract (CPE: 10 mg/kg). In all experiments, samples were collected at 0, 6, 12, 24 and 48 h after exposure. T4 exposure via dietary route produced differential and enhanced effects, compared with when the compound was injected to the broodstock. A significant association between exposure to dietary T4, elevated plasma steroid hormone levels, maturation-, spawning-, fertilization- and hatching rate, egg diameter, embryogenesis and larval growth were observed. Interestingly, we observed that broodstock groups fed with T4 doses spawned 20 days earlier than the control group. Thus, we propose that these differences may be attributed to higher systemic availability of T4 due to dietary exposure that is easily transferable to eggs and embryos, as opposed to injection that require absorption to increase bioavailability. Furthermore, our results show that LHRHa, CPE and HCG produced significant increase in spawning rate, but significantly reduced fertilization- and hatching rates. Waigieu seaperch is a new candidate for marine aquaculture in Vietnam and relatively little is known about the reproductive biology and endocrinology of this species. Therefore, the present study forms an integral basis for understanding the reproductive endocrinology of a tropical marine finfish with increasing aquaculture prospects and may also contribute in the development of sustainable aquaculture of this species in a developing country such as Vietnam. 2009 Elsevier Inc. All rights reserved.

  20. Flow through electrode with automated calibration

    DOEpatents

    Szecsody, James E [Richland, WA; Williams, Mark D [Richland, WA; Vermeul, Vince R [Richland, WA

    2002-08-20

    The present invention is an improved automated flow through electrode liquid monitoring system. The automated system has a sample inlet to a sample pump, a sample outlet from the sample pump to at least one flow through electrode with a waste port. At least one computer controls the sample pump and records data from the at least one flow through electrode for a liquid sample. The improvement relies upon (a) at least one source of a calibration sample connected to (b) an injection valve connected to said sample outlet and connected to said source, said injection valve further connected to said at least one flow through electrode, wherein said injection valve is controlled by said computer to select between said liquid sample or said calibration sample. Advantages include improved accuracy because of more frequent calibrations, no additional labor for calibration, no need to remove the flow through electrode(s), and minimal interruption of sampling.

  1. Clearance of phenylalanine ammonia-lyase from normal and tumor-bearing mice.

    PubMed

    Shen, R S; Fritz, R R; Abell, C W

    1977-04-01

    Yeast phenylalanine ammonia-lyase was administered i.p. to normal and tumor-bearing mice, and its clearance from plasma was studied. Single and multiple weekly injections at dosages of 10,20,50 and 100 units/kg were administered to C57BL female, C57BL X DBA/2F1 male, and A/J female mice. L5178Y murine lymphoblastic leukemia, B16 melanoma, BW10232 adenocarcinoma, and 15091A anaplastic carcinoma were implanted 7 to 11 days prior to enzyme injection in the appropriate host. After a single injection, the average plasma half-lives of phenylalanine ammonia-lyase were 18 to 24 hr in all groups studied. While the other tumors had no effect on the plasma level of phenylalanine ammonia-lyase after a single injection, L5178Y murine lymphoblastic leukemia and 15091A anaplastic carcinoma significantly depressed the maximal level of phenylalanine ammonia-lyase attained in the plasma. After repeated injections of phenylalanine ammonia-lyase, the initial plasma enzyme level was significantly reduced when 20 units/kg were administered, and the clearance of the enzyme from the plasma was greatly accelerated regardless of the amount administered. Furthermore, in tumor-bearing mice, the rate of clearance was significantly more rapid than in the appropriate non-tumor-bearing control.

  2. A multisyringe flow injection Winkler-based spectrophotometric analyzer for in-line monitoring of dissolved oxygen in seawater.

    PubMed

    Horstkotte, Burkhard; Alonso, Juan Carlos; Miró, Manuel; Cerdà, Víctor

    2010-01-15

    An integrated analyzer based on the multisyringe flow injection analysis approach is proposed for the automated determination of dissolved oxygen in seawater. The entire Winkler method including precipitation of manganese(II) hydroxide, fixation of dissolved oxygen, dissolution of the oxidized manganese hydroxide precipitate, and generation of iodine and tri-iodide ion are in-line effected within the flow network. Spectrophotometric quantification of iodine and tri-iodide at the isosbestic wavelength of 466nm renders enhanced method reliability. The calibration function is linear up to 19mgL(-1) dissolved oxygen and an injection frequency of 17 per hour is achieved. The multisyringe system features a highly satisfying signal stability with repeatabilities of 2.2% RSD that make it suitable for continuous determination of dissolved oxygen in seawater. Compared to the manual starch-end-point titrimetric Winkler method and early reported automated systems, concentrations and consumption of reagents and sample are reduced up to hundredfold. The versatility of the multisyringe assembly was exploited in the implementation of an ancillary automatic batch-wise Winkler titrator using a single syringe of the module for accurate titration of the released iodine/tri-iodide with thiosulfate.

  3. Impact of an experimental PRRSV and Streptococcus suis coinfection on the pharmacokinetics of ceftiofur hydrochloride after intramuscular injection in pigs.

    PubMed

    Day, D N; Sparks, J W; Karriker, L A; Stalder, K J; Wulf, L W; Zhang, J; Kinyon, J M; Stock, M L; Gehring, R; Wang, C; Ellingson, J; Coetzee, J F

    2015-10-01

    This study determined the impact of porcine reproductive and respiratory syndrome virus (PRRSV) and Streptococcus suis coinfection on the pharmacokinetic (PK) profile of ceftiofur hydrochloride in pigs after intramuscular (i.m.) injection. Eighteen clinically normal crossbred gilts were assigned by weight into a challenge group (10 pigs) and control group (eight pigs). Pigs in both groups received a single i.m. injection of ceftiofur hydrochloride (Excenel RTU Sterile Suspension; Zoetis) at a 5 mg/kg BW dose. Serial blood samples were collected to characterize the plasma concentration curve. After a 10 days drug washout period, the challenge group was inoculated with 2 mL of PRRSV isolate VR-2385 (10(5.75) 50% tissue culture infective doses per mL) intranasally and 8 days later inoculated S. suis. When clinical disease was evident, the second PK assessment began in both challenge and control groups. Coinfected pigs demonstrated lower values of AUC and CMAX , but higher values of Cl/F and Vz/F indicating drug kinetics were altered by infection. The data from this study have implications on ceftiofur treatment regimens in diseased pigs. © 2015 John Wiley & Sons Ltd.

  4. Dark Current Characterization of SW HgCdTe IRFPAs Detectors on Si Substrate with Long Time Integration

    NASA Astrophysics Data System (ADS)

    Song, P. Y.; Ye, Z. H.; Huang, A. B.; Chen, H. L.; Hu, X. N.; Ding, R. J.; He, L.

    2016-09-01

    The dark currents of two short wave (SW) HgCdTe infrared focal plane arrays (IRFPA) detectors hybridized with direct injection (DI) readout and capacitance transimpedance amplifier (CTIA) with long time integration were investigated. The cutoff wavelength of the two SW IRFPAs is about 2.6 μm at 84 K. The dark current densities of DI and CTIA samples are approximately 8.0 × 10-12 A/cm2 and 7.2 × 10-10 A/cm2 at 110 K, respectively. The large divergence of the dark current density might arise from the injection efficiency difference of the two readouts. The low injection efficiency of the DI readout, compared with the high injection efficiency of the CTIA readout at low temperature, makes the dark current density of the DI sample much lower than that of the CTIA sample. The experimental value of injection efficiency of the DI sample was evaluated as 1.1% which is consistent with its theoretical value.

  5. Simultaneous determination of PPCPs, EDCs, and artificial sweeteners in environmental water samples using a single-step SPE coupled with HPLC-MS/MS and isotope dilution.

    PubMed

    Tran, Ngoc Han; Hu, Jiangyong; Ong, Say Leong

    2013-09-15

    A high-throughput method for the simultaneous determination of 24 pharmaceuticals and personal care products (PPCPs), endocrine disrupting chemicals (EDCs) and artificial sweeteners (ASs) was developed. The method was based on a single-step solid phase extraction (SPE) coupled with high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) and isotope dilution. In this study, a single-step SPE procedure was optimized for simultaneous extraction of all target analytes. Good recoveries (≥ 70%) were observed for all target analytes when extraction was performed using Chromabond(®) HR-X (500 mg, 6 mL) cartridges under acidic condition (pH 2). HPLC-MS/MS parameters were optimized for the simultaneous analysis of 24 PPCPs, EDCs and ASs in a single injection. Quantification was performed by using 13 isotopically labeled internal standards (ILIS), which allows correcting efficiently the loss of the analytes during SPE procedure, matrix effects during HPLC-MS/MS and fluctuation in MS/MS signal intensity due to instrument. Method quantification limit (MQL) for most of the target analytes was below 10 ng/L in all water samples. The method was successfully applied for the simultaneous determination of PPCPs, EDCs and ASs in raw wastewater, surface water and groundwater samples collected in a local catchment area in Singapore. In conclusion, the developed method provided a valuable tool for investigating the occurrence, behavior, transport, and the fate of PPCPs, EDCs and ASs in the aquatic environment. Copyright © 2013 Elsevier B.V. All rights reserved.

  6. Demonstration of In situ Anaerobic Transformation of Toluene and Xylene Using Single-Well Push-Pull Tests and Deuterated BTEX Surrogates

    NASA Astrophysics Data System (ADS)

    Field, J. A.; Reusser, D. E.; Beller, H. R.; Istok, J. D.

    2001-12-01

    Obtaining unambiguous evidence of in-situ transformation of benzene, toluene, ethylbenzene and xylene (BTEX) in the subsurface is a difficult task. Recently, benzylsuccinic acid and its methyl analogues were shown to be unequivocal degradation products of anaerobic toluene and xylene biodegradation. Conducting tracer tests at BTEX-contaminated field sites is problematic because background contaminant concentrations potentially interfere with the interpretation of field test data. To avoid the time and cost associated with removing background contaminants, alternative approaches are needed. Deuterated analogs of toluene and xylene are well-suited for use in field tracer tests because they are inexpensive and can be distinguished analytically from background toluene and xylene. In this study, single-well push-pull tests, in which deuterated toluene and xylene were injected, were performed to assess the in-situ anaerobic biotransformation of toluene and xylene in BTEX-contaminated wells. A total of 4 single-well push-pull tests were conducted at BTEX-contaminated field sites near Portland, OR and Kansas City, KS. Test solutions consisting of 100 mg/L bromide, 250 mg/L nitrate, 0.4 to 2.5 mg/L toluene-d8, and 0.4 to 1.0 mg/L o-xylene-d10.were injected at a rate of 0.5 - 2 L/min. During the extraction phase, samples were taken daily to biweekly for up to 30 days. Samples for volatile organic analytes were collected in 40-mL volatile organic analysis (VOA) vials without headspace. Samples for BSA and methyl-BSA were collected in 1 L glass bottles and preserved with 5% (w/w) formalin. Samples were shipped on ice and stored at 4 C until analysis. Unambiguous evidence of toluene and xylene biotransformation was obtained with the in-situ formation of BSA and methyl-BSA. The concentrations of BSA ranged from below the detection limit (0.2 ug/L) to 1.5 ug/L. The concentrations of methyl-BSA ranged from below detection to the quantitation limit (0.7 ug/L). The highest BSA concentrations detected corresponded to 0.1 - 0.2 mol% of the injected deuterated toluene. Zero-order degradation rates for deuterated toluene, estimated as the rates of BSA formation, were 0.0004 to 0.001 day-1. Because methyl-BSA concentrations did not exceed the quantitation limit, the rate of xylene degradation could not be calculated. The formation of BSA and methyl-BSA was coupled with the utilization of nitrate, presumably due to denitrification. Transformation of toluene and xylene to BSA and methyl-BSA, respectively, was observed for wells characterized by low concentrations of toluene and xylene relative to total BTEX. To the best of our knowledge, this is the first report to document the use of deuterated BTEX surrogates in field-tracer experiments.

  7. Cellular immune response of pigeons in the conditions of endotoxin fever and pyrogenic tolerance.

    PubMed

    Dudek, K; Bednarek, D

    2011-01-01

    The aim of this study was to investigate changes in selected parameters of cellular immune response in the conditions of endotoxin fever and pyrogenic tolerance in pigeons. On the first day of observation the experimental birds (n = 18) were intravenously injected with Escherichia coli LPS at a dose of 10 microg/kg b.w., while the control animals (n = 6) received apyrogenic physiological saline also in the form of injection. On the second and the third day of the experiment LPS was injected additionally at 24 h intervals. Four and a half hours after the saline and pyrogen administration blood samples were collected from the control and experimental pigeons. The following immunological assays were performed: WBC, leucogram and immunophenotyping of lymphocyte subsets in peripheral blood, i.e. CD 3+ (T lymphocytes), CD 4+ (T helper lymphocytes) and CD 8+ (T suppressor/cytotoxic lymphocytes) cells. In the conditions of endotoxin fever (i.e. after the first LPS injection) leucopenia, monocytopenia, heterophilia and eosinophilia were observed. Additionally, the immunophenotyping of peripheral blood lymphocytes indicated an increase in percentage of CD 3+, CD 4+ and CD 8+ cells in response to the single injection of LPS. In contrast, the consecutive injections of LPS, which created a pyrogenic tolerance effect, caused a decrease in WBC value, heteropenia, eosinopenia and lymphocytosis. Moreover, during this state an increase in percentage of CD 3+ and CD 8+ cells was demonstrated in contrast to the percentage of CD 4+ lymphocytes. The general tendencies in cellular immune response of the affected pigeons in the conditions of endotoxin fever and pyrogenic tolerance aim at activation of defence mechanisms against LPS for its prompt elimination from the animal's organism.

  8. A functional form for injected MRI Gd-chelate contrast agent concentration incorporating recirculation, extravasation and excretion

    NASA Astrophysics Data System (ADS)

    Horsfield, Mark A.; Thornton, John S.; Gill, Andrew; Jager, H. Rolf; Priest, Andrew N.; Morgan, Bruno

    2009-05-01

    A functional form for the vascular concentration of MRI contrast agent after intravenous bolus injection was developed that can be used to model the concentration at any vascular site at which contrast concentration can be measured. The form is based on previous models of blood circulation, and is consistent with previously measured data at long post-injection times, when the contrast agent is fully and evenly dispersed in the blood. It allows the first-pass and recirculation peaks of contrast agent to be modelled, and measurement of the absolute concentration of contrast agent at a single time point allows the whole time course to be rescaled to give absolute contrast agent concentration values. This measure of absolute concentration could be performed at a long post-injection time using either MRI or blood-sampling methods. In order to provide a model that is consistent with measured data, it was necessary to include both rapid and slow extravasation, together with excretion via the kidneys. The model was tested on T1-weighted data from the descending aorta and hepatic portal vein, and on T*2-weighted data from the cerebral arteries. Fitting of the model was successful for all datasets, but there was a considerable variation in fit parameters between subjects, which suggests that the formation of a meaningful population-averaged vascular concentration function is precluded.

  9. Method for the quantification of vanadyl porphyrins in fractions of crude oils by High Performance Liquid Chromatography-Flow Injection-Inductively Coupled Plasma Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Wandekoken, Flávia G.; Duyck, Christiane B.; Fonseca, Teresa C. O.; Saint'Pierre, Tatiana D.

    2016-05-01

    High performance liquid chromatography hyphenated by flow injection to inductively coupled plasma mass spectrometry (HPLC-FI-ICP-MS) was used to investigate V linked to porphyrins present in fractions of crude oil. First, the crude oil sample was submitted to fractionation by preparative liquid chromatography with UV detection, at the porphyrin Soret band wavelength (400 nm). The obtained porphyrin fractions were then separated in a 250 mm single column, in the HPLC, and eluted with different mobile phases (methanol or methanol:toluene (80:20; v:v)). The quantification of V-porphyrins in the fractions eluted from HPLC was carried out by online measuring the 51V isotope in the ICP-MS, against vanadyl octaethylporphine standard solutions (VO-OEP), prepared in the same solvent as the mobile phase, and injected post-column directly into the plasma. A 20 μg L- 1 Ge in methanol was used as internal standard for minimizing non-spectral interference, such as short-term variations due to injection. The mathematical treatment of the signal based on Fast Fourier Transform smoothing algorithm was employed to improve the precision. The concentrations of V as V-porphyrins were between 2.7 and 11 mg kg- 1 in the fractions, which were close to the total concentration of V in the porphyrin fractions of the studied crude oil.

  10. A single exposure to cocaine during development elicits regionally-selective changes in basal basic Fibroblast Growth Factor (FGF-2) gene expression and alters the trophic response to a second injection.

    PubMed

    Giannotti, Giuseppe; Caffino, Lucia; Malpighi, Chiara; Melfi, Simona; Racagni, Giorgio; Fumagalli, Fabio

    2015-02-01

    During adolescence, the brain is maturing and more sensitive to drugs of abuse that can influence its developmental trajectory. Recently, attention has been focused on basic fibroblast growth factor (FGF-2) given that its administration early in life enhances the acquisition of cocaine self-administration and sensitization at adulthood (Turner et al. (Pharmacol Biochem Behav 92:100-4, 2009), Clinton et al. (Pharmacol Biochem Behav103:6-17, 2012)). Additionally, we found that abstinence from adolescent cocaine exposure long lastingly dysregulates FGF-2 transcription (Giannotti et al. (Psychopharmacology (Berl) 225:553-60, 2013 ). The objectives of the study are to evaluate if (1) a single injection of cocaine (20 mg/kg) at postnatal day 35 alters FGF-2 messenger RNA (mRNA) levels and (2) the first injection influences the trophic response to a second injection (10 mg/kg) provided 24 h or 7 days later. We found regional differences in the FGF-2 expression pattern as either the first or the second injection of cocaine by themselves upregulated FGF-2 mRNA in the medial prefrontal cortex and nucleus accumbens while downregulating it in the hippocampus. The first injection influences the trophic response of the second. Of note, 24 h after the first injection, accumbal and hippocampal FGF-2 changes produced by cocaine in saline-pretreated rats were prevented in cocaine-pretreated rats. Conversely, in the medial prefrontal cortex and hippocampus 7 days after the first injection, the cocaine-induced FGF-2 changes were modified by the subsequent exposure to the psychostimulant. These findings show that a single cocaine injection is sufficient to produce enduring changes in the adolescent brain and indicate that early cocaine priming alters the mechanisms regulating the trophic response in a brain region-specific fashion.

  11. Clinical effectiveness of multiple-drug injection treatment in unruptured ectopic pregnancies: a retrospective study.

    PubMed

    Dai, Quan; Wang, Lu-Lu; Shao, Xiao-Hui; Wang, Si-Ming; Dong, Xiao-Qiu

    2012-10-01

    To study the effect of local interventional treatment of unruptured ectopic pregnancies with multiple-drug injection guided by color Doppler sonography. In this retrospective analysis, 49 patients with an unruptured ectopic pregnancy were treated with two different local injection methods administered under sonographic guidance. The patients were divided into single-drug (n = 23) and multiple-drug (n = 26) injection groups, and they received a locally administered injection of methotrexate alone or a combination including methotrexate, hemocoagulase, antibiotics, and anti-inflammatory drugs, respectively. Overall, local injection treatment was successful in 44 patients. The 5 patients with failed treatment underwent laparotomy about 1 week after single-drug injection. Serum β-human chorionic gonadotropin (β-hCG ) levels, ectopic pregnancy mass sizes, blood flow at various points after treatment, the incidence of pelvic bleeding, and the time for serum β-hCG levels to return to normal and the mass to resolve were analyzed in the remaining 44 patients. Single-drug treatment was successful in 18 patients; 10 of 23 had low to moderate pelvic bleeding after treatment, and 5 were referred for surgery. All 26 patients were successfully treated by multiple-drug injection. Only 2 patients had a small amount of pelvic bleeding. Differences between groups were statistically significant (P < .05) for surgery rates, the incidence of pelvic bleeding, transient increases in serum β-hCG levels, mean days to normal β-hCG levels, mean days of mass resolution, and mean mass diameters 1 to 6 weeks after treatment. Local multiple-drug injection under color Doppler guidance is a new, safe, and effective method for treating unruptured ectopic pregnancies. It accelerates the serum β-hCG decline and facilitates mass resolution. This regimen is associated with a very low rate of pelvic bleeding, improves the success rate of conservative treatment, and, therefore, has value as an important clinical application.

  12. Oestradiol-17β plasma concentrations after intramuscular injection of oestradiol benzoate or oestradiol cypionate in llamas (Lama glama)

    PubMed Central

    2010-01-01

    Background Llamas (Lama glama) are induced ovulators and the process of ovulation depends on dominant follicular size. In addition, a close relationship between behavioural estrus and ovulation is not registered in llamas. Therefore, the exogenous control of follicular development with hormones aims to predict the optimal time to mate. Oestradiol-17β (E2) and its esters are currently used in domestic species, including camelids, in synchronization treatments. But, in llamas, there is no reports regarding the appropriate dosages to be used and most protocols have been designed by extrapolation from those recommended for other ruminants. The aim of the present study was to characterize plasma E2 concentrations in intact female llamas following a single intramuscular (i.m.) injection of two oestradiol esters: oestradiol benzoate (EB) and oestradiol cypionate (ECP). Methods Twelve non pregnant and non lactating sexually mature llamas were i.m. injected on day 0 with 2.5 mg of EB (EB group, n = 6) or ECP (ECP group, n = 6). Blood samples were collected immediately before injection, at 1, 6, 12, 24 h after treatment and then daily until day 14 post injection. Changes in hormone concentrations with time were analyzed in each group by analysis of variance (ANOVA) using a repeated measures (within-SS) design. Plasma E2 concentrations and area under the concentration-time curve (AUC) values were compared between groups by ANOVA. In all cases a Least-Significant Difference test (LSD) was used to determine differences between means. Hormonal and AUC data are expressed as mean ± S.E.M. Results Peak plasma E2 concentrations were achieved earlier and were higher in EB group than in ECP group. Thereafter, E2 returned to physiological concentrations earlier in EB group (day 5) than in ECP group (day 9). Although plasma E2 profiles differed over time among groups there were no differences between them on AUC values. Conclusions The i.m. injection of a single dose of both oestradiol esters resulted in plasma E2 concentrations exceeding physiological values for a variable period. Moreover, the plasma E2 profiles observed depended on the derivative of oestradiol administered. This basic information becomes relevant at defining treatment protocols including oestrogens in llamas. PMID:20149242

  13. Comparative pharmacokinetics of cefuroxime lysine after single intravenous, intraperitoneal, and intramuscular administration to rats.

    PubMed

    Zhao, Long-shan; Yin, Ran; Wei, Bin-bin; Li, Qing; Jiang, Zhen-yuan; Chen, Xiao-hui; Bi, Kai-shun

    2012-11-01

    To compare the pharmacokinetic parameters of cefuroxime lysine, a new second-generation of cephalosporin antibiotics, after intravenous (IV), intraperitoneal (IP), or intramuscular (IM) administration. Twelve male and 12 virgin female Sprague-Dawley rats, weighing from 200 to 250 g, were divided into three groups (n=4 for each gender in each group). The rats were administered a single dose (67.5 mg/kg) of cefuroxime lysine via IV bolus or IP or IM injection. Blood samples were collected and analyzed with a validated UFLC-MS/MS method. The concentration-time data were then calculated by compartmental and non-compartmental pharmacokinetic methods using DAS software. After IV, IP or IM administration, the plasma cefuroxime lysine disposition was best described by a tri-compartmental, bi-compartmental or mono-compartmental open model, respectively, with first-order elimination. The plasma concentration profiles were similar through the 3 administration routes. The distribution process was rapid after IV administration [t(1/2(d)), 0.10 ± 0.11 h vs 1.36 ± 0.65 and 1.25 ± 1.01 h]. The AUMC(0-∞) is markedly larger, and mean residence time (MRT) is greatly longer after IP administration than that in IV, or IM routes (AUMC(0-∞): 55.33 ± 20.34 vs 16.84 ± 4.85 and 36.17 ± 13.24 mg·h(2)/L; MRT: 0.93 ± 0.10 h vs 0.37 ± 0.07 h and 0.65 ± 0.05 h). The C(max) after IM injection was significantly higher than that in IP injection (73.51 ± 12.46 vs 49.09 ± 7.06 mg/L). The AUC(0-∞) in male rats were significantly higher than that in female rats after IM administration (66.38 ± 16.5 vs 44.23 ± 6.37 mg·h/L). There was no significantly sex-related difference in other pharmacokinetic parameters of cefuroxime lysine between male and female rats. Cefuroxime lysine shows quick absorption after IV injection, a long retension after IP injection, and a high C(max) after IM injection. After IM administration the AUC(0-∞) in male rats was significantly larger than that in female rats.

  14. Viscoelastic properties of rabbit vocal folds after augmentation.

    PubMed

    Hertegård, Stellan; Dahlqvist, Ake; Laurent, Claude; Borzacchiello, Assunta; Ambrosio, Luigi

    2003-03-01

    Vocal fold function is closely related to tissue viscoelasticity. Augmentation substances may alter the viscoelastic properties of vocal fold tissues and hence their vibratory capacity. We sought to investigate the viscoelastic properties of rabbit vocal folds in vitro after injections of various augmentation substances. Polytetrafluoroethylene (Teflon), cross-linked collagen (Zyplast), and cross-linked hyaluronan, hylan b gel (Hylaform) were injected into the lamina propria and the thyroarytenoid muscle of rabbit vocal folds. Dynamic viscosity of the injected vocal fold as a function of frequency was measured with a Bohlin parallel-plate rheometer during small-amplitude oscillation. All injected vocal folds showed a decreasing dynamic viscosity with increasing frequency. Vocal fold samples injected with hylan b gel showed the lowest dynamic viscosity, quite close to noninjected control samples. Vocal folds injected with polytetrafluoroethylene showed the highest dynamic viscosity followed by the collagen samples. The data indicated that hylan b gel in short-term renders the most natural viscoelastic properties to the vocal fold among the substances tested. This is of importance to restore/preserve the vibratory capacity of the vocal folds when glottal insufficiency is treated with injections.

  15. Administering Multiple Injectable Vaccines During a Single Visit—Summary of Findings From the Accelerated Introduction of Inactivated Polio Vaccine Globally

    PubMed Central

    Patel, Manish; Hampton, Lee M.; Burnett, Eleanor; Ehlman, Daniel C.; Garon, Julie; Cloessner, Emily; Chmielewski, Elizabeth; Hyde, Terri B.; Mantel, Carsten; Wallace, Aaron S.

    2017-01-01

    Abstract Background. In 2013, the World Health Organization’s (WHO’s) Strategic Advisory Group of Experts (SAGE) recommended that all 126 countries using only oral polio vaccine (OPV) introduce at least 1 dose of inactivated polio vaccine (IPV) into their routine immunization schedules by the end of 2015. In many countries, the addition of IPV would necessitate delivery of multiple injectable vaccines (hereafter, “multiple injections”) during a single visit, with infants receiving IPV alongside pentavalent vaccine (which covers diphtheria, tetanus, and whole-cell pertussis; hepatitis B; and Haemophilus influenzae type b) and pneumococcal vaccine. Unanticipated concerns emerged from countries over acceptability of multiple injections, sites of administration, and safety. We contextualized the issues surrounding multiple injections by documenting concerns associated with administration of ≥3 injections, existing evidence in the published literature, and findings of a systematic review on administration practices and techniques. Methods. Concerns associated with multiple-injection visits were documented from meetings and personal communications with immunization program managers. Published literature on the acceptability of multiple injections by providers and caregivers was summarized, and a systematic review of the literature on administration practices was completed on the following topics: spacing between injection sites (ie, vaccine spacing), site of injection, route of injection, and procedural preparedness. WHO and United Nations Children’s Fund data from 2013–2015 were used to assess multiple-injection visits included in national immunization schedules. Results. Healthcare provider and caregiver attitudes and practices indicated concerns about infant pain, potential adverse effects, and uncertainty about vaccine effectiveness with multiple-injection visits. Published literature reinforced the record of safety and acceptance of the recommended schedule of IPV by the SAGE, but the evidence was largely from developed countries. Parental acceptance of multiple injections was associated with a positive provider recommendation to the caregiver. Findings of the systematic review identified that the intramuscular route is preferred over the subcutaneous route for vaccine administration and that the vastus lateralis muscle is preferred over the deltoid muscle for intramuscular injections. Recommendations on vaccine spacing and procedural preparedness were based on practical necessities, but comparative evidence was not identified. During 2013–2015, 85 countries added IPV to their immunization schedules, 46 (55%) of which adopted a schedule resulting in 3 injectable vaccines being administered in a single visit. Conclusion. The multiple-injection experience identified gaps in guidance for future vaccine introductions. Global partner organizations quickly mobilized to assess, document, and communicate the existing global experience on multiple-injection visits. This evidence-based approach provided reassurance to opinion leaders, health workers, and professional societies, thus encouraging uptake of IPV as a second or third injection in an accelerated manner globally. PMID:28838188

  16. Stabilized single-injection inactivated polio vaccine elicits a strong neutralizing immune response.

    PubMed

    Tzeng, Stephany Y; McHugh, Kevin J; Behrens, Adam M; Rose, Sviatlana; Sugarman, James L; Ferber, Shiran; Langer, Robert; Jaklenec, Ana

    2018-05-21

    Vaccination in the developing world is hampered by limited patient access, which prevents individuals from receiving the multiple injections necessary for protective immunity. Here, we developed an injectable microparticle formulation of the inactivated polio vaccine (IPV) that releases multiple pulses of stable antigen over time. To accomplish this, we established an IPV stabilization strategy using cationic polymers for pH modulation to enhance traditional small-molecule-based stabilization methods. We investigated the mechanism of this strategy and showed that it was broadly applicable to all three antigens in IPV. Our lead formulations released two bursts of IPV 1 month apart, mimicking a typical vaccination schedule in the developing world. One injection of the controlled-release formulations elicited a similar or better neutralizing response in rats, considered the correlate of protection in humans, than multiple injections of liquid vaccine. This single-administration vaccine strategy has the potential to improve vaccine coverage in the developing world. Copyright © 2018 the Author(s). Published by PNAS.

  17. Intraperitoneal Injection Is Not a Suitable Administration Route for Single-Walled Carbon Nanotubes in Biomedical Applications.

    PubMed

    Liu, Xudong; Guo, Qing; Zhang, Yuchao; Li, Jinquan; Li, Rui; Wu, Yang; Ma, Ping; Yang, Xu

    2016-01-01

    Given the extensive application of carbon nanotubes (CNTs) in biomedical fields, there is increasing concern regarding unintentional health impacts. Research into safe usage is therefore increasingly necessary. This study investigated the responses of the mouse brain to single-walled CNTs (SWCNTs) delivered via intraperitoneal (IP) injection and compared these results with the previous study where SWCNTs were delivered via intravenous (IV) injection so as to explore which administration route is potentially better for SWCNTs application. This study suggests SWCNTs delivered via IP injection can have negative effects on the mouse brain through oxidative stress and inflammation at high concentration exposure, but these responses were not consistent and showed no dose-dependent effect. In a previous study, the results showed that IV-delivered SWCNTs induced a more consistent and dose-dependent effect. The comparison of the 2 studies suggested that using SWCNTs at a safe dosage delivered via IV injection may be a better administration route for SWCNTs in biomedical applications.

  18. Stabilized single-injection inactivated polio vaccine elicits a strong neutralizing immune response

    PubMed Central

    Tzeng, Stephany Y.; McHugh, Kevin J.; Behrens, Adam M.; Rose, Sviatlana; Sugarman, James L.; Ferber, Shiran; Jaklenec, Ana

    2018-01-01

    Vaccination in the developing world is hampered by limited patient access, which prevents individuals from receiving the multiple injections necessary for protective immunity. Here, we developed an injectable microparticle formulation of the inactivated polio vaccine (IPV) that releases multiple pulses of stable antigen over time. To accomplish this, we established an IPV stabilization strategy using cationic polymers for pH modulation to enhance traditional small-molecule–based stabilization methods. We investigated the mechanism of this strategy and showed that it was broadly applicable to all three antigens in IPV. Our lead formulations released two bursts of IPV 1 month apart, mimicking a typical vaccination schedule in the developing world. One injection of the controlled-release formulations elicited a similar or better neutralizing response in rats, considered the correlate of protection in humans, than multiple injections of liquid vaccine. This single-administration vaccine strategy has the potential to improve vaccine coverage in the developing world. PMID:29784798

  19. Studies of the effects of curvature on dilution jet mixing

    NASA Technical Reports Server (NTRS)

    Holdeman, James D.; Srinivasan, Ram; Reynolds, Robert S.; White, Craig D.

    1992-01-01

    An analytical program was conducted using both three-dimensional numerical and empirical models to investigate the effects of transition liner curvature on the mixing of jets injected into a confined crossflow. The numerical code is of the TEACH type with hybrid numerics; it uses the power-law and SIMPLER algorithms, an orthogonal curvilinear coordinate system, and an algebraic Reynolds stress turbulence model. From the results of the numerical calculations, an existing empirical model for the temperature field downstream of single and multiple rows of jets injected into a straight rectangular duct was extended to model the effects of curvature. Temperature distributions, calculated with both the numerical and empirical models, are presented to show the effects of radius of curvature and inner and outer wall injection for single and opposed rows of cool dilution jets injected into a hot mainstream flow.

  20. Krokodile Injectors in Ukraine: Fueling the HIV Epidemic?

    PubMed

    Booth, Robert E; Davis, Jonathan M; Brewster, John T; Lisovska, Oksana; Dvoryak, Sergey

    2016-02-01

    This study was designed to assess the characteristics of krokodile injectors, a recent phenomenon in Ukraine, and HIV-related risk factors among people who inject drugs (PWID). In three Ukraine cities, Odessa, Donetsk and Nikolayev, 550 PWID were recruited between December 2012 and October 2013 using modified targeted sampling methods. The sample averaged 31 years of age and they had been injecting for over 12 years. Overall, 39 % tested positive for HIV, including 45 % of krokodile injectors. In the past 30 days, 25 % reported injecting krokodile. Those who injected krokodile injected more frequently (p < 0.001) and they injected more often with others (p = 0.005). Despite knowing their HIV status to be positive, krokodile users did not reduce their injection frequency, indeed, they injected as much as 85 % (p = 0.016) more frequently than those who did not know their HIV status or thought they were negative. This behavior was not seen in non-krokodile using PWID. Although only a small sample of knowledgeable HIV positive krokodile users was available (N = 12), this suggests that krokodile users may disregard their HIV status more so than nonkrokodile users. In spite of widespread knowledge of its harmful physical consequences, a growing number of PWID are turning to injecting krokodile in Ukraine. Given the recency of krokodile use the country, the associated higher frequency of injecting, a propensity to inject more often with others, and what could be a unique level of disregard of HIV among krokodile users, HIV incidence could increase in future years.

  1. Phase-front measurements of an injection-locked AlGaAs laser-diode array

    NASA Technical Reports Server (NTRS)

    Cornwell, Donald M., Jr.; Rall, Jonathan A. R.; Abshire, James B.

    1989-01-01

    The phase-front quality of the primary spatial lobe emitted from an injection-locked gain-guided AlGaAs laser-diode array is measured by using an equal-path, phase-shifting Mach-Zehnder interferometer. Root-mean-square phase errors of 0.037 + or - 0.003 wave are measured for the single spatial lobe, which contained 240-mW cw output power in a single longitudinal mode. This phase-front quality corresponds to a Strehl ratio of S = 0.947, which results in a 0.23-dB power loss from the single lobe's ideal diffraction-limited power. These values are comparable with those measured for single-stripe index-guided AlGaAs lasers.

  2. Applications of polyamide/cellulose fiber/wollastonite composites for microcellular injection molding

    Treesearch

    Herman Winata; Lih-Sheng Turng; Daniel F. Caulfield; Tom Kuster; Rick Spindler; Rod Jacobson

    2003-01-01

    In this study, a cellulose-fiber-reinforced Polyamide-6 (PA-6) composite, a hybrid composite (PA-6/cellulose/Wollastonite), and the neat PA-6 resin were injection molded into ASTM test–bar samples with conventional and microcellular injection molding. The impact and tensile strengths of molded samples were measured and the Scanning Electron Microscopy (SEM) images were...

  3. Fracturing of porous rock induced by fluid injection

    NASA Astrophysics Data System (ADS)

    Stanchits, Sergei; Mayr, Sibylle; Shapiro, Serge; Dresen, Georg

    2011-04-01

    We monitored acoustic emission (AE) activity and brittle failure initiated by water injection into initially dry critically stressed cylindrical specimens of Flechtingen sandstone of 50 mm diameter and 105-125 mm length. Samples were first loaded in axial direction at 40-50 MPa confining pressure at dry conditions close to peak stress. Subsequently distilled water was injected either at the bottom of specimen or via a central borehole at pore pressures of 5-30 MPa. Water injection into stressed porous sandstone induced a cloud of AE events located close to the migrating water front. Water injection was monitored by periodic ultrasonic velocity measurements across the sample. Propagation of the induced cloud of AE was faster in the direction parallel to bedding than normal to it, indicating permeability anisotropy. Water injection was associated with significant AE activity demonstrating increased contribution of tensile source type. Brittle failure was accompanied by increased contribution of shear and pore collapse source types. At a critical pore pressure, a brittle fault nucleated from a cloud of induced AE events in all samples. Microstructural analysis of fractured samples shows excellent agreement between location of AE hypocenters and macroscopic faults.

  4. Efficient mobilization of haematopoietic progenitors after a single injection of pegylated recombinant human granulocyte colony-stimulating factor in mouse strains with distinct marrow-cell pool sizes.

    PubMed

    de Haan, G; Ausema, A; Wilkens, M; Molineux, G; Dontje, B

    2000-09-01

    We have compared the efficacy of a single injection of SD/01, a newly engineered, pegylated form of recombinant human granulocyte colony stimulating factor (rhG-CSF), with a single injection of glycosylated rhG-CSF (Filgrastim). SD/01 was administered to regular and recombinant inbred strains of mice (AKR, C57L/J, DBA/2, C57BL/6, AKXL) known to have widely distinct marrow-cell pool sizes and proliferation kinetics. A single injection of G-CSF was unable to mobilize granulocyte-macrophage colony-forming units (CFU-GM). In sharp contrast, a single dose of SD/01 resulted in massive mobilization of progenitors and stem cells. Although all mice strains showed qualitatively similar mobilization responses, large interstrain differences remained. C57L and C57BL/6 mice mobilized relatively poorly, whereas AKR and DBA/2 mice showed threefold to tenfold superior responses. In order to explain these different phenotypes, we studied the effects of SD/01 in nine AKXL recombinant inbred strains, derived from well-responding AKR and poorly responding C57L parental strains. The best predictor for SD/01 responsiveness in these strains was marrow cellularity prior to mobilization. Comparison of the AKXL strain distribution pattern for marrow cellularity with loci previously mapped in these strains showed complete concordance with Aat, a serine protease inhibitor mapping to chromosome 12.

  5. N-linked glycoprotein analysis using dual-extraction ultrahigh-performance liquid chromatography and electrospray tandem mass spectrometry.

    PubMed

    Siu, S O; Lam, Maggie P Y; Lau, Edward; Yeung, William S B; Cox, David M; Chu, Ivan K

    2010-01-01

    Although reverse-phase liquid chromatography (RP-LC) is a common technique for peptide separation in shotgun proteomics and glycoproteomics, it often provides unsatisfactory results for the analysis of glycopeptides and glycans. This bias against glycopeptides makes it difficult to study glycoproteins. By coupling mass spectrometry (MS) with a combination of RP-LC and normal-phase (NP)-LC as an integrated front-end separation system, we demonstrate that effective identification and characterization of both peptides and glycopeptides mixtures, and their constituent glycan structures, can be achieved from a single sample injection event.

  6. MEDICAL INJECTION

    NASA Image and Video Library

    1963-06-10

    S62-08371 (1962) --- The automatic medical injectors carried on the Mercury-Atlas 9 flight. The injectors provide the astronaut with injection tubes of Tigan, for preventing motion sickness and Demerol, for relieving pain. The tubes encased in the block are stowed in the astronauts survival kit. The single injection tubes are placed in a pocket of the astronauts spacesuit. Photo credit: NASA

  7. Simultaneous Determination of Fluid Shifts during Thermal Stress in a Small Animal Model,

    DTIC Science & Technology

    1985-09-01

    extracellular fluid voitmie (BCF) was measured using a single injection c- inulin , technique, and plasma voilme (PV) was determined by ca.rdio--yreen dye...using tritiated water, extracell1ular fluid volume (ECF) was measured using a single injection C- inulin technique, and plasma volume (PV) was...space. However, inulin (10) has several advantages over the aforementioned because it Is not metabolized, stored, or incorporated by cells or

  8. Prevention of 3-methylcholanthrene-induced fibrosarcomas in rats pre-inoculated with endogenous rat retrovirus

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fish, D.C.; Demarais, J.T.; Djurickovic, D.B.

    1981-04-01

    Weanling Fischer 344 rats received a single intraperitoneal injection of a 1000-fold concentrated preparation of endogenous nontransforming rat retrovirus. Ten days later, the rats were each given a single subcutaneous injection of 3-methylcholanthrene. The rats inoculated with the endogenous rat retrovirus were significantly protected against the development of cancer, whereas uninoculated rats and rats given one of several murine tetroviruses or baboon retrovirus were not protected.

  9. 50 Mb/s, 220-mW Laser-Array Transmitter

    NASA Technical Reports Server (NTRS)

    Cornwell, Donald M., Jr.

    1992-01-01

    Laser transmitter based on injection locking produces single-wavelength, diffraction-limited, single-lobe beam. Output stage is array of laser diodes producing non-diffraction-limited, multi-mode beam in absence of injection locking. Suitable for both free-space and optical-fiber communication systems. Because beam from transmitter focused to spot as small as 5 micrometers, devices usable for reading and writing optical disks at increased information densities. Application also in remote sensing and ranging.

  10. Numerical Simulations of Two-Phase Reacting Flow in a Single-Element Lean Direct Injection (LDI) Combustor Using NCC

    NASA Technical Reports Server (NTRS)

    Liu, Nan-Suey; Shih, Tsan-Hsing; Wey, C. Thomas

    2011-01-01

    A series of numerical simulations of Jet-A spray reacting flow in a single-element lean direct injection (LDI) combustor have been conducted by using the National Combustion Code (NCC). The simulations have been carried out using the time filtered Navier-Stokes (TFNS) approach ranging from the steady Reynolds-averaged Navier-Stokes (RANS), unsteady RANS (URANS), to the dynamic flow structure simulation (DFS). The sub-grid model employed for turbulent mixing and combustion includes the well-mixed model, the linear eddy mixing (LEM) model, and the filtered mass density function (FDF/PDF) model. The starting condition of the injected liquid spray is specified via empirical droplet size correlation, and a five-species single-step global reduced mechanism is employed for fuel chemistry. All the calculations use the same grid whose resolution is of the RANS type. Comparisons of results from various models are presented.

  11. A prospective randomized trial of 1 versus 2 injections during EUS-guided celiac plexus block for chronic pancreatitis pain.

    PubMed

    LeBlanc, Julia K; DeWitt, Jon; Johnson, Cynthia; Okumu, Wycliffe; McGreevy, Kathleen; Symms, Michelle; McHenry, Lee; Sherman, Stuart; Imperiale, Thomas

    2009-04-01

    The efficacy of 1-injection versus a 2-injections method of EUS-guided celiac plexus block (EUS-CPB) in patients with chronic pancreatitis is not known. To compare the clinical effectiveness and safety of EUS-CPB by using 1 versus 2 injections in patients with chronic pancreatitis and pain. The secondary aim is to identify factors that predict responsiveness. A prospective randomized study. EUS-CPB was performed by using bupivacaine and triamcinolone injected into 1 or 2 sites at the level of the celiac trunk during a single EUS-CPB procedure. Duration of pain relief, onset of pain relief, and complications. Fifty [corrected] subjects were enrolled (23 received 1 injection, 27 [corrected] received 2 injections). The median duration of pain relief in the 31 responders was 28 days (range 1-673 days). [corrected] Fifteen [corrected] of 23 (65%) [corrected] subjects who received 1 injection [corrected] had relief from pain compared with 16 of 27 (59%) [corrected] subjects who received 2 injections [corrected] (P = .67). [corrected] The median times to onset in the 1-injection and 2-injections groups were 21 and 14 days, respectively (P = .99). No correlation existed between duration of pain relief and time to onset of pain relief or onset within 24 hours. Age, sex, race, prior EUS-CPB, and smoking or alcohol history did not predict duration of pain relief. Telephone interviewers were not blinded. There was no difference in duration of pain relief or onset of pain relief in subjects with chronic pancreatitis and pain when the same total amount of medication was delivered in 1 or 2 injections during a single EUS-CPB procedure. Both methods were safe.

  12. [Post-marketing safety surveillance of Diemailing Kudiezi injection: real world study in 30 233 cases].

    PubMed

    Liao, Xing; Yu, Dan-Dan; Xie, Yan-Ming; Zhang, Yun-Ling; He, Yan; Zhang, Yin; Liu, Yan; Yi, Dan-Hui; Wang, Yong-Yan

    2017-08-01

    This study was aimed to obtain the incidence of adverse drug reaction (ADR) of Diemailing Kudiezi injection, explore its characteristics, related risk factors and application in real world. A prospective single cohort study was conducted from 25 hospitals (including Chinese medicine hospitals and Western medicine hospitals) for 4 years. 30 233 consecutive inpatients using Diemailing Kudiezi injection were observed. Their general information was analyzed by using statistic frequency description. Association rules were used to analyze the correlation between comorbidities or drug combinations; the influential factors for ADRs were initially screened by using cross contingency method and Chi-square test, and then Group LASSAO method was used for further analysis. 54 patients with adverse drug events and 30 patients with ADRs were reported among 30 233 patients, with a total ADR incidence of 0.099%[95%CI (0.06%, 0.13%)]. There were 27 patients identified as the "general" ADR, one patients with "severe" ADR (anaphylactic shock) and two patients with new ADRs. ADR occurred most in 30 min after using Diemailing Kudiezi injection, in a total of 16 patients. The most ADRs were palpitation, vomiting, chills, pruritus and rash, 6 times for each symptom. Diemailing Kudiezi injection was well tolerated in the general population. The overall incidence of adverse reactions was rare, with high safety. However, the real incidence of ADRs may be underestimated in this study, and the blood samples were not obtained for the patients, so further mechanism studies shall be conducted. Copyright© by the Chinese Pharmaceutical Association.

  13. Does pain relief by CT-guided indirect cervical nerve root injection with local anesthetics and steroids predict pain relief after decompression surgery for cervical nerve root compression?

    PubMed

    Antoniadis, Alexander; Dietrich, Tobias J; Farshad, Mazda

    2016-10-01

    The relationship of pain relief from a recently presented CT-guided indirect cervical nerve root injection with local anesthetics and steroids to surgical decompression as a treatment for single-level cervical radiculopathy is not clear. This retrospective study aimed to compare the immediate and 6-week post-injection effects to the short- and long-term outcomes after surgical decompression, specifically in regard to pain relief. Patients (n = 39, age 47 ± 10 years) who had undergone CT-guided indirect injection with local anesthetics and steroids as an initial treatment for single cervical nerve root radiculopathy and who subsequently needed surgical decompression were included retrospectively. Pain levels (VAS scores) were monitored before, immediately after, and 6 weeks after injection (n = 34), as well as 6 weeks (n = 38) and a mean of 25 months (SD ± 12) after surgical decompression (n = 36). Correlation analysis was performed to find potential associations of pain relief after injection and after surgery to investigate the predictive value of post-injection pain relief. There was no correlation between immediate pain relief after injection (-32 ± 27 %) and 6 weeks later (-7 ± 19 %), (r = -0.023, p = 0.900). There was an association by tendency between immediate pain relief after injection and post-surgical pain relief at 6 weeks (-82 ± 27 %), (r = 0.28, p = 0.08). Pain relief at follow-up remained high at -70 ± 21 % and was correlated with the immediate pain amelioration effect of the injection (r = 0.37, p = 0.032). Five out of seven patients who reported no pain relief from injection had a pain relief from surgery in excess of 50 %. The amount of immediate radiculopathic pain relief after indirect cervical nerve root injection is associated with the amount of pain relief achieved at long-term follow-up after surgical decompression of single-level cervical radiculopathy. Patients can still expect sufficient pain relief from surgery even if they did not respond to the cervical infiltration.

  14. Modeling of single event transients with dual double-exponential current sources: Implications for logic cell characterization

    DOE PAGES

    Black, Dolores Archuleta; Robinson, William H.; Wilcox, Ian Zachary; ...

    2015-08-07

    Single event effects (SEE) are a reliability concern for modern microelectronics. Bit corruptions can be caused by single event upsets (SEUs) in the storage cells or by sampling single event transients (SETs) from a logic path. Likewise, an accurate prediction of soft error susceptibility from SETs requires good models to convert collected charge into compact descriptions of the current injection process. This paper describes a simple, yet effective, method to model the current waveform resulting from a charge collection event for SET circuit simulations. The model uses two double-exponential current sources in parallel, and the results illustrate why a conventionalmore » model based on one double-exponential source can be incomplete. Furthermore, a small set of logic cells with varying input conditions, drive strength, and output loading are simulated to extract the parameters for the dual double-exponential current sources. As a result, the parameters are based upon both the node capacitance and the restoring current (i.e., drive strength) of the logic cell.« less

  15. A Rapid Method for Optimizing Running Temperature of Electrophoresis through Repetitive On-Chip CE Operations

    PubMed Central

    Kaneda, Shohei; Ono, Koichi; Fukuba, Tatsuhiro; Nojima, Takahiko; Yamamoto, Takatoki; Fujii, Teruo

    2011-01-01

    In this paper, a rapid and simple method to determine the optimal temperature conditions for denaturant electrophoresis using a temperature-controlled on-chip capillary electrophoresis (CE) device is presented. Since on-chip CE operations including sample loading, injection and separation are carried out just by switching the electric field, we can repeat consecutive run-to-run CE operations on a single on-chip CE device by programming the voltage sequences. By utilizing the high-speed separation and the repeatability of the on-chip CE, a series of electrophoretic operations with different running temperatures can be implemented. Using separations of reaction products of single-stranded DNA (ssDNA) with a peptide nucleic acid (PNA) oligomer, the effectiveness of the presented method to determine the optimal temperature conditions required to discriminate a single-base substitution (SBS) between two different ssDNAs is demonstrated. It is shown that a single run for one temperature condition can be executed within 4 min, and the optimal temperature to discriminate the SBS could be successfully found using the present method. PMID:21845077

  16. New diesel injection nozzle flow measuring device

    NASA Astrophysics Data System (ADS)

    Marčič, Milan

    2000-04-01

    A new measuring device has been developed for diesel injection nozzle testing, allowing measuring of the steady flow through injection nozzle and the injection rate. It can be best applied for measuring the low and high injection rates of the pintle and single hole nozzle. In steady flow measuring the fuel pressure at the inlet of the injection nozzle is 400 bar. The sensor of the measuring device measures the fuel charge, resulting from fuel rubbing in the fuel injection system, as well as from the temperature gradient in the sensor electrode. The electric charge is led to the charge amplifier, where it is converted into electric current and amplified. The amplifier can be used also to measure the mean injection rate value.

  17. The biological effects of radium-224 injected into dogs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Muggenburg, B.A.; Hahn, F.F.; Boecker, B.B.

    1996-08-01

    A life-span study was conducted in 128 beagle dogs to determine the biological effects of intravenously injected {sup 224}Ra chloride. The {sup 224}Ra chloride was prepared by the same method used for intravenous injections in humans who were treated for ankylosing spondylitis and tuberculosis. Thus the results obtained from dogs can be compared directly to the population of treated humans, both for the elucidation of the effect of exposure rate and for comparison with other radionuclides for which data for humans are unavailable. Using equal numbers of males and females, the dogs were injected with one of four levels ofmore » {sup 224}Ra resulting in initial body burdens of approximately 13, 40, 120 or 350 kBq of {sup 224}Ra kg{sup -1} body mass. A control group of dogs was injected with diluent only. All dogs were divided further into three groups for which the amount of injected {sup 224}Ra (half-life of 3.62 days) or diluent was given in a single injection or divided equally into 10 or 50 weekly injections. As a result of these three injection schedules, the accumulation of dose from the injected {sup 224}Ra was distributed over approximately 1, 3 or 12 months. Each injection schedule included four different injection levels resulting in average absorbed {alpha}-particle doses to bone of 0.1, 0.3, 1 and 3 Gy, respectively. The primary early effect observed was a hematological dyscrasia in the dogs receiving either of the two highest injection levels. The effect was most severe in the dogs receiving a single injection of {sup 224}Ra and resulted in the death of three dogs injected at the highest level. The late-occurring biological effects were tumors. Bone tumors were the most common followed by tumors in the nasal mucosa. 52 refs., 8 figs., 8 tabs.« less

  18. Tunable single frequency fiber laser based on FP-LD injection locking.

    PubMed

    Zhang, Aiqin; Feng, Xinhuan; Wan, Minggui; Li, Zhaohui; Guan, Bai-ou

    2013-05-20

    We propose and demonstrate a tunable single frequency fiber laser based on Fabry Pérot laser diode (FP-LD) injection locking. The single frequency operation principle is based on the fact that the output from a FP-LD injection locked by a multi-longitudinal-mode (MLM) light can have fewer longitudinal-modes number and narrower linewidth. By inserting a FP-LD in a fiber ring laser cavity, single frequency operation can be possibly achieved when stable laser oscillation established after many roundtrips through the FP-LD. Wavelength switchable single frequency lasing can be achieved by adjusting the tunable optical filter (TOF) in the cavity to coincide with different mode of the FP-LD. By adjustment of the drive current of the FP-LD, the lasing modes would shift and wavelength tunable operation can be obtained. In experiment, a wavelength tunable range of 32.4 nm has been obtained by adjustment of the drive current of the FP-LD and a tunable filter in the ring cavity. Each wavelength has a side-mode suppression ratio (SMSR) of at least 41 dB and a linewidth of about 13 kHz.

  19. Native and sodium dodecyl sulfate-capillary gel electrophoresis of proteins on a single microchip.

    PubMed

    Tsai, Shuo-Wen; Loughran, Michael; Suzuki, Hiroaki; Karube, Isao

    2004-02-01

    Simultaneous electrophoresis of both native and Sodium dodecyl sulfate (SDS) proteins was observed on a single microchip within 20 min. The capillary array prevented lateral diffusion of SDS components and avoided cross contamination of native protein samples. The planar sputtered electrode format provided a more uniform distribution of separation voltage into each of the 36 parallel microchannel capillaries than platinum wire electrodes commonly used in conventional electrophoresis. The customized geometry of the stacking capillary machined into the cover plate of the microchip facilitated reproducible sample injection without the requirement for stacking gel. Polyimide served as a mask and facilitated insulation of the anode and cathode to prevent electrode lift off and deterioration during continuous electrophoresis, even at a constant current of 8 mA. Improved protein separation was observed during capillary electrophoresis at lower currents. Ferguson plot analysis confirmed the electrophoretic mobility of native globular proteins in accordance with their charge and size. Corresponding Ferguson plot analysis of SDS-associated proteins on the same chip confirmed separation of marker proteins according to their molecular weight.

  20. [Protective effect of Tanreqing injection on acute hepatic injury induced by CCl4 in rats].

    PubMed

    Lei, Yang; Zhou, Ai-Min; Guo, Tao; Tan, Ye; Tao, Yan-Yan; Liu, Cheng-Hai

    2013-04-01

    To observe the protective effect of Tanreqing injection(TRQ) on carbon tetrachloride-induced acute hepatic injury in rats. Rats were randomly divided into the normal group and the model group, and injected subcutaneously with 100% CCl4 5 mL x kg(-1) to establish the single CCl4 infection model, in order to observe the changes in rat liver injury after 3 h and 6 h. Subsequently, the multiple CCl4 infection liver injury model was reproduced by subcutaneously injecting 100% CCl4 (5 mL x kg(-1)), 50% CCl4 olive oil solution (2 mL x kg(-1)) and then 20% CCl4 olive oil solution (2 mL x kg(-1)). At 6 h after the first CCl4 injection, the rats were divided into six groups: the model group, the control group, the diammonium glycyrrhizinate-treated group, and TRQ high, middle and low dose groups. They were injected through caudal veins, while a normal control group was set up. Their weight and liver-body ratio were observed. Hepatic inflammation was observed with HE staining. Assay kits were adopted to detect ALT, AST, T. Bil, D. Bil, CHE, TBA, gamma-GT and Alb. According to the single injection model, serum AST and T. Bil of model rats were obviously increased at 6 h after single subcutaneous injection of CCl4, with disordered lobular structure in liver tissues, notable swollen liver cells and remarkable liver injury. According to the results of the multiple injection pharmacological experiment, compared with the normal group, the model group had higher serum ALT, AST, and gamma-GT activities (P < 0. 05), TBA and T. Bil contents (P < 0.05) and lower CHE activity (P < 0.05). HE staining showed disorganized lobular structure in liver tissues and notable ballooning degeneration in liver cells. Compared with the model group, TRQ high and middle dose groups and the diammonium glycyrrhizinate-treated group showed significant charges in serum liver function and inflammation in liver cells. Specifically, TRQ high and middle dose groups were superior to the diammonium glycyrrhizinate-treated group. Tanreqing injection has significant protective effect on CCl4-induced acute hepatic injury in rats.

  1. Effect of injection pressure on performance, emission, and combustion characteristics of diesel-acetylene-fuelled single cylinder stationary CI engine.

    PubMed

    Srivastava, Anmesh Kumar; Soni, Shyam Lal; Sharma, Dilip; Jain, Narayan Lal

    2018-03-01

    In this paper, the effect of injection pressure on the performance, emission, and combustion characteristics of a diesel-acetylene fuelled single cylinder, four-stroke, direct injection (DI) diesel engine with a rated power of 3.5 kW at a rated speed of 1500 rpm was studied. Experiments were performed in dual-fuel mode at four different injection pressures of 180, 190, 200, and 210 bar with a flow rate of 120 LPH of acetylene and results were compared with that of baseline diesel operation. Experimental results showed that highest brake thermal efficiency of 27.57% was achieved at injection pressure of 200 bar for diesel-acetylene dual-fuel mode which was much higher than 23.32% obtained for baseline diesel. Carbon monoxide, hydrocarbon, and smoke emissions were also measured and found to be lower, while the NO x emissions were higher at 200 bar in dual fuel mode as compared to those in other injection pressures in dual fuel mode and also for baseline diesel mode. Peak cylinder pressure, net heat release rate, and rate of pressure rise were also calculated and were higher at 200 bar injection pressure in dual fuel mode.

  2. Optimization of a therapeutic protocol for intravenous injection of human mesenchymal stem cells after cerebral ischemia in adult rats.

    PubMed

    Omori, Yoshinori; Honmou, Osamu; Harada, Kuniaki; Suzuki, Junpei; Houkin, Kiyohiro; Kocsis, Jeffery D

    2008-10-21

    The systemic injection of human mesenchymal stem cells (hMSCs) prepared from adult bone marrow has therapeutic benefits after cerebral artery occlusion in rats, and may have multiple therapeutic effects at various sites and times within the lesion as the cells respond to a particular pathological microenvironment. However, the comparative therapeutic benefits of multiple injections of hMSCs at different time points after cerebral artery occlusion in rats remain unclear. In this study, we induced middle cerebral artery occlusion (MCAO) in rats using intra-luminal vascular occlusion, and infused hMSCs intravenously at a single 6 h time point (low and high cell doses) and various multiple time points after MCAO. From MRI analyses lesion volume was reduced in all hMSC cell injection groups as compared to serum alone injections. However, the greatest therapeutic benefit was achieved following a single high cell dose injection at 6 h post-MCAO, rather than multiple lower cell infusions over multiple time points. Three-dimensional analysis of capillary vessels in the lesion indicated that the capillary volume was equally increased in all of the cell-injected groups. Thus, differences in functional outcome in the hMSC transplantation subgroups are not likely the result of differences in angiogenesis, but rather from differences in neuroprotective effects.

  3. Optical gain in 1.3-μm electrically driven dilute nitride VCSOAs

    PubMed Central

    2014-01-01

    We report the observation of room-temperature optical gain at 1.3 μm in electrically driven dilute nitride vertical cavity semiconductor optical amplifiers. The gain is calculated with respect to injected power for samples with and without a confinement aperture. At lower injected powers, a gain of almost 10 dB is observed in both samples. At injection powers over 5 nW, the gain is observed to decrease. For nearly all investigated power levels, the sample with confinement aperture gives slightly higher gain. PMID:24417791

  4. Interactional group discussion: results of a controlled trial using a behavioral intervention to reduce the use of injections in public health facilities.

    PubMed

    Hadiyono, J E; Suryawati, S; Danu, S S; Sunartono; Santoso, B

    1996-04-01

    Injections are commonly overused in Indonesia. More than 60% of patients attending public health facilities receive at least one injection, which increases clinical risk and has adverse economic impact. This study assesses the efficacy of an innovative behavioral intervention, the Interactional Group Discussion (IGD), for reducing the overuse of injections. This study was a controlled trial in a single district with 24 public health centers randomized to intervention and control groups. Prescribers in the intervention group were invited to one IGD, each of which consisted of 6 prescribers and 6 patients; a total of 24 IGDs were held in a 4-week period, and all invited prescribers participated. The groups, which lasted 90-120 minutes, were facilitated by a behavioral scientist and a clinician, who also served as a scientific resource person. The hypothesized mechanism of behavior change involved reality testing prescribers' assumptions about patient beliefs, imparting scientific information about injection efficacy, and establishing peer norms about correct behavior. Outcomes were measured by a retrospective prescribing survey covering the periods 3 months before and 3 months after the intervention, with samples of 100 prescriptions per center per month. Rates of injection and average number of drugs per prescription were computed separately for each center, and t-tests were used to compare pre-post changes in outcomes in both groups. Results showed a significant decrease in injection use from 69.5 to 42.3% in the intervention group, compared to a decrease from 75.6 to 67.1% among controls [-18.7.0% intervention vs control, 95% CI = (-31.1%, -6.4%), P < 0.025]. There was also a significant reduction in average number of drugs per prescription [-0.37 drugs prescribed per patient, 95% CI = (-0.04, -0.52), P < 0.05], indicating that injections were not substituted with other drugs. We conclude that the IGD significantly reduces the overuse of injections. It is suggested to try out other behavioral interventions to improve the rational use of drugs.

  5. Comparison of intraosseous and infiltration injections for venous lidocaine blood concentrations and heart rate changes after injection of 2% lidocaine with 1:100,000 epinephrine.

    PubMed

    Wood, Mark; Reader, Al; Nusstein, John; Beck, Mike; Padgett, David; Weaver, Joel

    2005-06-01

    The purpose of this prospective, randomized study was to compare the venous blood levels of lidocaine and heart rate changes after intraosseous and infiltration injections of 1.8 ml of 2% lidocaine with 1:100,000 epinephrine. Using a crossover design, 20 subjects randomly received an intraosseous and infiltration injection at two separate appointments. The heart rate was measured using a pulse oximeter. Venous blood samples were collected before the injections and at 2, 5, 10, 15, 20, 25, 30, 45, and 60 min after the injections. The blinded plasma samples were analyzed for lidocaine concentrations using high-performance liquid chromatography (HPLC). The intraosseous injection resulted in a statistically significant increase in heart rate, when compared to the infiltration injection, during solution deposition and for 2 min after the injection. The plasma levels of lidocaine were not statistically different for maxillary anterior intraosseous and infiltration injections when using 1.8 ml of 2% lidocaine with 1:100,000 epinephrine.

  6. Development of a split-flow system for high precision variable sample introduction in supercritical fluid chromatography.

    PubMed

    Sakai, Miho; Hayakawa, Yoshihiro; Funada, Yasuhiro; Ando, Takashi; Fukusaki, Eiichiro; Bamba, Takeshi

    2017-09-15

    In this study, we propose a novel variable sample injection system based on full-loop injection, named the split-flow sample introduction system, for application in supercritical fluid chromatography (SFC). In this system, the mobile phase is split by the differential pressure between two back pressure regulators (BPRs) after full-loop injection suitable for SFC, and this differential pressure determines the introduction rate. Nine compounds with a wide range of characteristics were introduced with high reproducibility and universality, confirming that a robust variable sample injection system was achieved. We also investigated the control factors of our proposed system. Sample introduction was controlled by the ratio between the column-side pressure drops in splitless and split flow, ΔP columnsideinsplitless and ΔP columnsideinsplit , respectively, where ΔP columnsideinsplitless is related to the mobile phase flow rate and composition and the column resistance. When all other conditions are kept constant, increasing the make-up flow induces an additional pressure drop on the column side of the system, which leads to a reduced column-side flow rate, and hence decreased the amount of sample injected, even when the net pressure drop on the column side remains the same. Thus, sample introduction could be highly controlled at low sample introduction rate, regardless of the introduction conditions. This feature is advantageous because, as a control factor, the solvent in the make-up pump is independent of the column-side pressure drop. Copyright © 2017. Published by Elsevier B.V.

  7. Maternal intravenous treatment with either azithromycin or solithromycin clears Ureaplasma parvum from the amniotic fluid in an ovine model of intrauterine infection.

    PubMed

    Miura, Yuichiro; Payne, Matthew S; Keelan, Jeffrey A; Noe, Andres; Carter, Sean; Watts, Rory; Spiller, Owen B; Jobe, Alan H; Kallapur, Suhas G; Saito, Masatoshi; Stock, Sarah J; Newnham, John P; Kemp, Matthew W

    2014-09-01

    Intrauterine infection with Ureaplasma spp. is strongly associated with preterm birth and adverse neonatal outcomes. We assessed whether combined intraamniotic (IA) and maternal intravenous (IV) treatment with one of two candidate antibiotics, azithromycin (AZ) or solithromycin (SOLI), would eradicate intrauterine Ureaplasma parvum infection in a sheep model of pregnancy. Sheep with singleton pregnancies received an IA injection of U. parvum serovar 3 at 85 days of gestational age (GA). At 120 days of GA, animals (n=5 to 8/group) received one of the following treatments: (i) maternal IV SOLI with a single IA injection of vehicle (IV SOLI only); (ii) maternal IV SOLI with a single IA injection of SOLI (IV+IA SOLI); (iii) maternal IV AZ and a single IA injection of vehicle (IV AZ only); (iv) maternal IV AZ and a single IA injection of AZ (IV+IA AZ); or (v) maternal IV and single IA injection of vehicle (control). Lambs were surgically delivered at 125 days of GA. Treatment efficacies were assessed by U. parvum culture, quantitative PCR, enzyme-linked immunosorbent assay, and histopathology. Amniotic fluid (AF) from all control animals contained culturable U. parvum. AF, lung, and chorioamnion from all AZ- or SOLI-treated animals (IV only or IV plus IA) were negative for culturable U. parvum. Relative to the results for the control, the levels of expression of interleukin 1β (IL-1β), IL-6, IL-8, and monocyte chemoattractant protein 2 (MCP-2) in fetal skin were significantly decreased in the IV SOLI-only group, the MCP-1 protein concentration in the amniotic fluid was significantly increased in the IV+IA SOLI group, and there was no significant difference in the histological inflammation scoring of lung or chorioamnion among the five groups. In the present study, treatment with either AZ or SOLI (IV only or IV+IA) effectively eradicated macrolide-sensitive U. parvum from the AF. There was no discernible difference in antibiotic therapy efficacy between IV-only and IV+IA treatment regimens relative to the results for the control. Copyright © 2014, American Society for Microbiology. All Rights Reserved.

  8. The effectiveness of a double-stem injection valve in controlling combustion in a compression-ignition engine

    NASA Technical Reports Server (NTRS)

    Spanogle, J A; Whitney, E G

    1931-01-01

    An investigation was made to determine to what extent the rates of combustion in a compression-ignition engine can be controlled by varying the rates of fuel injection. The tests showed that the double-stem valve operated satisfactorily under all normal injection conditions; the rate of injection has a definite effect on the rate of combustion; the engine performance with the double-stem valve was inferior to that obtained with a single-stem valve; and the control of injection rates permitted by an injection valve of two stages of discharge is not sufficient to effect the desired rates of combustion.

  9. Strategies for safe injections.

    PubMed Central

    Battersby, A.; Feilden, R.; Stoeckel, P.; Da Silva, A.; Nelson, C.; Bass, A.

    1999-01-01

    In 1998, faced with growing international concern, WHO set out an approach for achieving injection safety that encompassed all elements from patients' expectations and doctors' prescribing habits to waste disposal. This article follows that lead and describes the implications of the approach for two injection technologies: sterilizable and disposable. It argues that focusing on any single technology diverts attention from the more fundamental need for health services to develop their own comprehensive strategies for safe injections. National health authorities will only be able to ensure that injections are administered safely if they take an approach that encompasses the whole system, and choose injection technologies that fit their circumstances. PMID:10680247

  10. A Facile Droplet-Chip-Time-Resolved Inductively Coupled Plasma Mass Spectrometry Online System for Determination of Zinc in Single Cell.

    PubMed

    Wang, Han; Chen, Beibei; He, Man; Hu, Bin

    2017-05-02

    Single cell analysis is a significant research field in recent years reflecting the heterogeneity of cells in a biological system. In this work, a facile droplet chip was fabricated and online combined with time-resolved inductively coupled plasma mass spectrometry (ICPMS) via a microflow nebulizer for the determination of zinc in single HepG2 cells. On the focusing geometric designed PDMS microfluidic chip, the aqueous cell suspension was ejected and divided by hexanol to generate droplets. The droplets encapsulated single cells remain intact during the transportation into ICP for subsequent detection. Under the optimized conditions, the frequency of droplet generation is 3-6 × 10 6 min -1 , and the injected cell number is 2500 min -1 , which can ensure the single cell encapsulation. ZnO nanoparticles (NPs) were used for the quantification of zinc in single cells, and the accuracy was validated by conventional acid digestion-ICPMS method. The ZnO NPs incubated HepG2 cells were analyzed as model samples, and the results exhibit the heterogeneity of HepG2 cells in the uptake/adsorption of ZnO NPs. The developed online droplet-chip-ICPMS analysis system achieves stable single cell encapsulation and has high throughput for single cell analysis. It has the potential in monitoring the content as well as distribution of trace elements/NPs at the single cell level.

  11. Intradetrusor Injections of Onabotulinum Toxin-A in Children With Urinary Incontinence due to Neurogenic Detrusor Overactivity Refractory to Antimuscarinic Treatment.

    PubMed

    Tarcan, Tufan; Akbal, Cem; Sekerci, Cağri A; Top, Tuncay; Simşek, Ferruh

    2014-04-01

    This was a prospective single-arm study to assess the efficacy and safety of intradetrusor injections of onabotulinum toxin-A in children with urinary incontinence associated with neurogenic detrusor overactivity due to myelomeningocele. All patients had failed the first-line treatment of a combination of oral antimuscarinics and intermittent catheterization. The study group consisted of 31 children with myelomeningocele with a mean age of 7.95 years (range, 5-3 years) who were followed up for a mean of 29 weeks. The amount of onabotulinum toxin A injected was 10 U/kg with a maximal dose of 300 U. There were 20 to 30 injection sites with rigid cystoscopic guidance under general anesthesia. Thirty of 31 patients reported dryness between intermittent catheterization intervals. The mean reduction in maximum detrusor pressure and the mean increase in maximum cystometric capacity from baseline were 53% and 51.5%, respectively, 6 weeks after injection. We found a 324% increase in mean bladder compliance and a 57% increase in mean intermittent catheterization volumes. The mean duration of efficacy was 28 weeks with a single injection and 36 weeks for repeated injections (minimum, 16 weeks; maximum, 52 weeks). The mean time interval between repeated onabotulinum toxin-A injections was 7 months (maximum, 13 months). Intradetrusor injections of onabotulinum toxin-A were well tolerated. Onabotulinum toxin-A injections into the bladder wall provide a significant symptomatic and urodynamic improvement in children with neurogenic detrusor overactivity due to myelomeningocele who are on intermittent catheterization. The treatment seems to be safe and very well tolerated.

  12. Determination of nitrite and nitrate in water samples by an automated hydrodynamic sequential injection method.

    PubMed

    Somnam, Sarawut; Jakmunee, Jaroon; Grudpan, Kate; Lenghor, Narong; Motomizu, Shoji

    2008-12-01

    An automated hydrodynamic sequential injection (HSI) system with spectrophotometric detection was developed. Thanks to the hydrodynamic injection principle, simple devices can be used for introducing reproducible microliter volumes of both sample and reagent into the flow channel to form stacked zones in a similar fashion to those in a sequential injection system. The zones were then pushed to the detector and a peak profile was recorded. The determination of nitrite and nitrate in water samples by employing the Griess reaction was chosen as a model. Calibration graphs with linearity in the range of 0.7 - 40 muM were obtained for both nitrite and nitrate. Detection limits were found to be 0.3 muM NO(2)(-) and 0.4 muM NO(3)(-), respectively, with a sample throughput of 20 h(-1) for consecutive determination of both the species. The developed system was successfully applied to the analysis of water samples, employing simple and cost-effective instrumentation and offering higher degrees of automation and low chemical consumption.

  13. High-pressure liquid chromatography with direct injection of gas sample.

    PubMed

    Astanin, Anton I; Baram, Grigory I

    2017-06-09

    The conventional method of using liquid chromatography to determine the composition of a gaseous mixture entails dissolving vapors in a suitable solvent, then obtaining a chromatograph of the resulting solution. We studied the direct introduction of a gaseous sample into a C18 reversed-phase column, followed by separation of the components by HPLC with UV detection. Since the chromatography was performed at high pressure, vapors readily dissolved in the eluent and the substances separated in the column as effectively as in liquid samples. Samples were injected into the column in two ways: a) through the valve without a flow stop; b) after stopping the flow and relieving all pressure. We showed that an injectable gas volume could reach 70% of column dead volume. When an injected gaseous sample volume was less than 10% of the column dead volume, the resulting peaks were symmetrical and the column efficiency was high. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Phase locking of a semiconductor double-quantum-dot single-atom maser

    NASA Astrophysics Data System (ADS)

    Liu, Y.-Y.; Hartke, T. R.; Stehlik, J.; Petta, J. R.

    2017-11-01

    We experimentally study the phase stabilization of a semiconductor double-quantum-dot (DQD) single-atom maser by injection locking. A voltage-biased DQD serves as an electrically tunable microwave frequency gain medium. The statistics of the maser output field demonstrate that the maser can be phase locked to an external cavity drive, with a resulting phase noise L =-99 dBc/Hz at a frequency offset of 1.3 MHz. The injection locking range, and the phase of the maser output relative to the injection locking input tone are in good agreement with Adler's theory. Furthermore, the electrically tunable DQD energy level structure allows us to rapidly switch the gain medium on and off, resulting in an emission spectrum that resembles a frequency comb. The free running frequency comb linewidth is ≈8 kHz and can be improved to less than 1 Hz by operating the comb in the injection locked regime.

  15. A new rat model of portal hypertension induced by intraportal injection of microspheres

    PubMed Central

    Li, Xiang-Nong; Benjamin, IS; Alexander, B

    1998-01-01

    AIM: To produce a new rat model of portal hypertension by intraportal injection of microspheres. METHODS: Measured aliquots of single or different-sized microspheres (15, 40, 80μm) were injected into the portal vein to block intrahepatic portal radicals. The resultant changes in arterial,portal,hepatic venous and splenic pulp pressures were monitored. The liver and lungs were excised for histological examination. RESULTS: Portal venous pressure was elevated from basal value of 0.89-1.02 kPa to a steady-state of 1.98-3.19 kPa following the sequential injections of single- or different-sized microspheres, with a markedly lowered mean arterial pressure. However, a small-dose injection of 80 μm microspheres (1.8 × 105) produced a steady-state portal venous pressure of 2.53 × 0.17 kPa, and all rats showed normal arterial pressures. In addition, numerous microspheres were found in the lungs in all experimental groups. CONCLUSION: Portal hypertension can be reproduced in rats by intraportal injection of microspheres at a small dose of 80 μm (1.8 × 105). Intrahepatic portal-systemic shunts probably exist in the normal rat liver. PMID:11819236

  16. In vivo induction of interferon gamma expression in grey horses with metastatic melanoma resulting from direct injection of plasmid DNA coding for equine interleukin 12.

    PubMed

    Müller, J-M V; Wissemann, J; Meli, M L; Dasen, G; Lutz, H; Heinzerling, L; Feige, K

    2011-11-01

    Whole blood pharmacokinetics of intratumourally injected naked plasmid DNA coding for equine Interleukin 12 (IL-12) was assessed as a means of in vivo gene transfer in the treatment of melanoma in grey horses. The expression of induced interferon gamma (IFN-g) was evaluated in order to determine the pharmacodynamic properties of in vivo gene transduction. Seven grey horses bearing melanoma were injected intratumourally with 250 µg naked plasmid DNA coding for IL-12. Peripheral blood and biopsies from the injection site were taken at 13 time points until day 14 post injection (p.i.). Samples were analysed using quantitative real-time PCR. Plasmid DNA was quantified in blood samples and mRNA expression for IFN-g in tissue samples. Plasmid DNA showed fast elimination kinetics with more than 99 % of the plasmid disappearing within 36 hours. IFN-g expression increased quickly after IL-12 plasmid injection, but varied between individual horses. Intratumoural injection of plasmid DNA is a feasible method for inducing transgene expression in vivo. Biological activity of the transgene IL-12 was confirmed by measuring expression of IFN-g.

  17. High-sensitivity detection of biological amines using fast Hadamard transform CE coupled with photolytic optical gating.

    PubMed

    Braun, Kevin L; Hapuarachchi, Suminda; Fernandez, Facundo M; Aspinwall, Craig A

    2007-08-01

    Here, we report the first utilization of Hadamard transform CE (HTCE), a high-sensitivity, multiplexed CE technique, with photolytic optical gating sample injection of caged fluorescent labels for the detection of biologically important amines. Previous implementations of HTCE have relied upon photobleaching optical gating sample injection of fluorescent dyes. Photolysis of caged fluorescent labels reduces the fluorescence background, providing marked enhancements in sensitivity compared to photobleaching. Application of fast Hadamard transform CE (fHTCE) for fluorescein-based dyes yields a ten-fold higher sensitivity for photolytic injections compared to photobleaching injections, due primarily to the reduced fluorescent background provided by caged fluorescent dyes. Detection limits as low as 5 pM (ca. 18 molecules per injection event) were obtained with on-column LIF detection using fHTCE in less than 25 s, with the capacity for continuous, online separations. Detection limits for glutamate and aspartate below 150 pM (1-2 amol/injection event) were obtained using photolytic sample injection, with separation efficiencies exceeding 1 x 10(6) plates/m and total multiplexed separation times as low as 8 s. These results strongly support the feasibility of this approach for high-sensitivity dynamic chemical monitoring applications.

  18. Durable recovery of the macular architecture and functionality of a diagnosed age-related macular degeneration 1 year after a single intravitreal injection of dobesilate

    PubMed Central

    Cuevas, P; Outeiriño, L A; Azanza, C; Giménez-Gallego, G

    2013-01-01

    Among the age-related diseases that affect vision, age-related macular degeneration is the most frequent cause of blindness in patients older than 60 years. In this communication, we report the full anatomical and functional recovery of a patient diagnosed with wet age-related macular degeneration 1 year after a single intravitreal injection of dobesilate. PMID:24225910

  19. Long-term correction of obesity and diabetes in genetically obese mice by a single intramuscular injection of recombinant adeno-associated virus encoding mouse leptin

    PubMed Central

    Murphy, John E.; Zhou, Shangzhen; Giese, Klaus; Williams, Lewis T.; Escobedo, Jaime A.; Dwarki, Varavani J.

    1997-01-01

    The ob/ob mouse is genetically deficient in leptin and exhibits a phenotype that includes obesity and non-insulin-dependent diabetes melitus. This phenotype closely resembles the morbid obesity seen in humans. In this study, we demonstrate that a single intramuscular injection of a recombinant adeno-associated virus (AAV) vector encoding mouse leptin (rAAV-leptin) in ob/ob mice leads to prevention of obesity and diabetes. The treated animals show normalization of metabolic abnormalities including hyperglycemia, insulin resistance, impaired glucose tolerance, and lethargy. The effects of a single injection have lasted through the 6-month course of the study. At all time points measured the circulating levels of leptin in the serum were similar to age-matched control C57 mice. These results demonstrate that maintenance of normal levels of leptin (2–5 ng/ml) in the circulation can prevent both the onset of obesity and associated non-insulin-dependent diabetes. Thus a single injection of a rAAV vector expressing a therapeutic gene can lead to complete and long-term correction of a genetic disorder. Our study demonstrates the long-term correction of a disease caused by a genetic defect and proves the feasibility of using rAAV-based vectors for the treatment of chronic disorders like obesity. PMID:9391128

  20. Intrathecal opioids versus epidural local anesthetics for labor analgesia: a meta-analysis.

    PubMed

    Bucklin, Brenda A; Chestnut, David H; Hawkins, Joy L

    2002-01-01

    Some anesthesiologists contend that intrathecal opioid administration has advantages over conventional epidural techniques during labor. Randomized clinical trials comparing analgesia and obstetric outcome using single-injection intrathecal opioids versus epidural local anesthetics suggest that intrathecal opioids provide comparable analgesia with few serious side effects. This meta-analysis compared the analgesic efficacy, side effects, and obstetric outcome of single-injection intrathecal opioid techniques versus epidural local anesthetics in laboring women. Relevant clinical studies were identified using electronic and manual searches of the literature covering the period from 1989 to 2000. Searches used the following descriptors: intrathecal analgesia, spinal opioids, epidural analgesia, epidural local anesthetics, and analgesia for labor. Data were extracted from 7 randomized clinical trials comparing analgesic measures, incidence of motor block, pruritus, nausea, hypotension, mode of delivery, and/or Apgar scores. Combined test results indicated comparable analgesic efficacy 15 to 20 minutes after injection with single-injection intrathecal opioid administration. Intrathecal opioid injections were associated with a greater incidence of pruritus (odds ratio, 14.01; 99% confidence interval, 6.9 to 28.3), but there was no difference in the incidence of nausea or in the method of delivery. Published studies suggest that intrathecal opioids provide comparable early labor analgesia when compared with epidural local anesthetics. Intrathecal opioid administration results in a greater incidence of pruritus. The choice of technique does not appear to affect the method of delivery.

  1. The pharmacokinetics of, and humoral responses to, antigen delivered by microencapsulated liposomes.

    PubMed

    Cohen, S; Bernstein, H; Hewes, C; Chow, M; Langer, R

    1991-12-01

    The feasibility of creating a s.c. depot for sustained protein delivery with the goal of enhancing antigen immunogenicity was investigated. The depot was designed as antigen-laden liposomes of hydrogenated egg phosphatidylcholine and cholesterol (1:1 molar ratio) encapsulated in alginate-poly(L-lysine) microcapsules and evaluated using iodinated bovine serum albumin (BSA) as a model antigen. The in vivo release behavior of the liposomes and microencapsulated liposomes (MELs) was evaluated from the BSA serum concentration profiles after s.c. injection into rats and the pharmacokinetic parameters of 125I-labeled BSA appearance after s.c. or i.v. injections of BSA in saline. Maximal BSA concentrations were detected 11 h after s.c. injection in all rats. The BSA serum concentrations decreased rapidly in rats injected with BSA in saline or Freund's adjuvant and less rapidly in rats injected with BSA in liposomes or MELs. Four to 5 weeks after injection, BSA-associated radioactivity was detected only in sera of rats injected with BSA in liposomes or MELs. Fifty days after injection, 50% of the originally injected BSA was recovered form the s.c. sites of rats injected with BSA in MELs; no radioactivity was recovered from the other three groups of rats. The antigen-reactive antibody levels induced in rats immunized with BSA in MELs were 2- to 3-fold higher than those obtained in rats immunized with BSA in liposomes, saline, or Freund's adjuvant. More significantly, high antibody levels were maintained for more than 150 days after a single injection of BSA in MELs, suggesting that MELs can serve as a long-term single-dose immunization vehicle.

  2. Numerical investigation of improving the performance of a single expansion ramp nozzle at off-design conditions by secondary injection

    NASA Astrophysics Data System (ADS)

    Lv, Zheng; Xu, Jinglei; Mo, Jianwei

    2017-04-01

    The performance of a single expansion ramp nozzle (SERN) is poor due to over-expansion at off-design conditions. The present study focuses on improving the SERN performance by secondary injection on the cowl and is carried out by using the k - ε RNG turbulence model. The incidence shock wave resulting from the secondary injection impinges on the expansion ramp, resulting in separation and the increase of the pressure distribution along the ramp. The performance of the SERN can be improved significantly, and the augmentation of the thrust coefficient, lift and pitch moment can be as high as 3.16%, 29.43% and 41.67%, respectively, when the nozzle pressure ratio (NPR) is 10. The location of the injection has a considerable effect on the lift and pitching moment, and the direction of the pitch moment can be changed from nose-up to nose-down when the injection is on the tail of the cowl. The effect of the injection on the axial thrust coefficient is much more apparent, if the operation NPR is far from the design point, and however, the results for the lift and pitching moment are opposite. The increases of injection total pressure and injection width have positive impacts on the SERN performance. And if the parameter φ maintains constant, the axial thrust coefficient would increase when the injection total pressure decreases, so low energy flow can also be used as the secondary injection without decreasing the lift and pitching moment. The mass flow rate of the injection can be decreased by applying the higher total temperature flow without reducing the performance of the SERN.

  3. 15 mJ single-frequency Ho:YAG laser resonantly pumped by a 1.9 µm laser diode

    NASA Astrophysics Data System (ADS)

    Na, Q. X.; Gao, C. Q.; Wang, Q.; Zhang, Y. X.; Gao, M. W.; Ye, Q.; Li, Y.

    2016-09-01

    A 2.09 µm injection-seeded single-frequency Ho:YAG laser resonantly pumped by a 1.91 µm laser diode is demonstrated for the first time. The seed laser is a continuous wave (CW) Ho:YAG non-planar ring oscillator. 15.15 mJ single-frequency output energy is obtained from the injection-seeded Q-switched Ho:YAG laser, with a pulse repetition rate of 200 Hz and a pulse width of 109 ns. The half-width of the pulse spectrum is measured to be 4.19 MHz by using the heterodyne technique. The fluctuation of the center frequency of the single-frequency pulses is 1.52 MHz (root mean square (RMS)) in 1 h.

  4. Successful adenovirus-mediated wild-type p53 gene transfer in patients with bladder cancer by intravesical vector instillation.

    PubMed

    Kuball, Jürgen; Wen, Shu Fen; Leissner, Joachim; Atkins, Derek; Meinhardt, Patricia; Quijano, Erlinda; Engler, Heidrun; Hutchins, Beth; Maneval, Daniel C; Grace, Michael J; Fritz, Mary Ann; Störkel, Stefan; Thüroff, Joachim W; Huber, Christoph; Schuler, Martin

    2002-02-15

    To study safety, feasibility, and biologic activity of adenovirus-mediated p53 gene transfer in patients with bladder cancer. Twelve patients with histologically confirmed bladder cancer scheduled for cystectomy were treated on day 1 with a single intratumoral injection of SCH 58500 (rAd/p53) at cystoscopy at one dose level (7.5 x 10(11) particles) or a single intravesical instillation of SCH 58500 with a transduction-enhancing agent (Big CHAP) at three dose levels (7.5 x 10(11) to 7.5 x 10(13) particles). Cystectomies were performed in 11 patients on day 3, and transgene expression, vector distribution, and biologic markers of transgene activity were assessed by molecular and immunohistochemical methods in tumors and normal bladder samples. Specific transgene expression was detected in tissues from seven of eight assessable patients treated with intravesical instillation of SCH 58500 but in none of three assessable patients treated with intratumoral injection of SCH 58500. Induction of RNA and protein expression of the p53 target gene p21/WAF1 was demonstrated in samples from patients treated with SCH 58500 instillation at higher dose levels. Distribution studies after intravesical instillation of SCH 58500 revealed both high transduction efficacy and vector penetration throughout the whole urothelium and into submucosal tumor cells. No dose-limiting toxicity was observed, and side effects were local and of transient nature. Intravesical instillation of SCH 58500 combined with a transduction-enhancing agent is safe, feasible, and biologically active in patients with bladder cancer. Studies to evaluate the clinical efficacy of this treatment in patients with localized high-risk bladder cancer are warranted.

  5. Home delivery of heat-stable vaccines in Indonesia: outreach immunization with a prefilled, single-use injection device.

    PubMed Central

    Sutanto, A.; Suarnawa, I. M.; Nelson, C. M.; Stewart, T.; Soewarso, T. I.

    1999-01-01

    Extending immunization coverage to underserved populations will require innovative immunization strategies. This study evaluated one such strategy: the use of a prefilled, single-use injection device for outreach immunization by village midwives. The device, UniJect, is designed to prevent refilling or reuse. Stored at ambient temperatures for up to 1 month in midwives' homes, vaccine-filled UniJect devices were immediately available for outreach. Between July 1995 and April 1996, 110 midwives on the Indonesia islands of Lombok and Bali visited the homes of newborn infants to deliver hepatitis B vaccine to the infants and tetanus toxoid to their mothers. Observations and interviews showed that the midwives used the device properly and safely to administer approximately 10,000 sterile injections in home settings. There were no problems with excessive heat exposure during the storage or delivery of vaccine. Injection recipients and midwives expressed a strong preference for the UniJect device over a standard syringe. Use of the prefilled device outside the cold chain simplified the logistics and facilitated the speed and efficiency of home visits, while the single-dose format minimized vaccine wastage. PMID:10083709

  6. Comparison of single intra operative versus an intra operative and two post operative injections of the triamcinolone after wedge excision of keloids of helix.

    PubMed

    Bashir, Muhammad Mustehsan; Ahmad, Hazqeel; Yousaf, Nadeem; Khan, Farid Ahmad

    2015-07-01

    To compare single intra-operative versus an intra-operative and two post-operative injections of triamcinolone after wedge excision of keloids of helix. The randomised controlled trial was conducted at the King Edward Medical University, Lahore, from January, 2011, to March, 2014, and comprised female patients over 14 years of age presenting with post-piercing keloids of helix not treated previously by any means and amenable to wedge excision. The subjects were divided into Group A who were given a single intra-operative injection of triamcinolone, and Group B who had an intra-operative and two post-operative injections of triamcinolone. Extra-lesional wedge excision of keloids was done, followed by infiltration of flaps and wound base with 0.5-1cc of triamcinolone 40mg/cc. Group B patients were given additional injections of triamcinolone at 1st and 2nd monthly visits. Both groups were observed for the evidence of hypertrophy or complications. Development of hypertrophy within one year of completion of treatment was considered recurrence. The 70 patients in the study were divided into two equal groups of 35(50%) each. The mean age of Group A was 22.34±4.95 years and that of Group B was 22.88±4.22 years (p=0.624). The Mean size of the keloids was 2.54±0.516 cm(2) in Group A and 2.61±0.569 cm(2) in Group B (p=0.613). Recurrence rate in Group A was 3(8.5%) and 2(5.7%) in Group B (p= 0.64). The complication rate was 3(8.5%) in Group A and 8(22.8%) in Group B (p=0.10). Single injection of triamcinolone was as effective as three in reducing recurrence with less complication rate.

  7. Development of a translational model to screen medications for cocaine use disorder I: Choice between cocaine and food in rhesus monkeys.

    PubMed

    Johnson, Amy R; Banks, Matthew L; Blough, Bruce E; Lile, Joshua A; Nicholson, Katherine L; Negus, S Stevens

    2016-08-01

    Homologous cocaine self-administration procedures in laboratory animals and humans may facilitate translational research for medications development to treat cocaine dependence. This study, therefore, sought to establish choice between cocaine and an alternative reinforcer in rhesus monkeys responding under a procedure back-translated from previous human studies and homologous to a human laboratory procedure described in a companion paper. Four rhesus monkeys with chronic indwelling intravenous catheters had access to cocaine injections (0, 0.043, 0.14, or 0.43mg/kg/injection) and food (0, 1, 3, or 10 1g banana-flavored food pellets). During daily 5h sessions, a single cocaine dose and a single food-reinforcer magnitude were available in 10 30-min trials. During the initial "sample" trial, the available cocaine and food reinforcer were delivered non-contingently. During each of the subsequent nine "choice" trials, responding could produce either the cocaine or food reinforcer under an independent concurrent progressive-ratio schedule. Preference was governed by the cocaine dose and food-reinforcer magnitude, and increasing cocaine doses produced dose-dependent increases in cocaine choice at all food-reinforcer magnitudes. Effects of the candidate medication lisdexamfetamine (0.32-3.2mg/kg/day) were then examined on choice between 0.14mg/kg/injection cocaine and 10 pellets. Under baseline conditions, this reinforcer pair maintained an average of approximately 6 cocaine and 3 food choices. Lisdexamfetamine dose-dependently decreased cocaine choice in all monkeys, but food choice was not significantly altered. These results support utility of this procedure in rhesus monkeys as one component of a platform for translational research on medications development to treat cocaine use disorder. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  8. Pharmacokinetic evaluation of three different intramuscular doses of nandrolone decanoate: analysis of serum and urine samples in healthy men.

    PubMed

    Bagchus, Wilma M; Smeets, Jean M W; Verheul, Herman A M; De Jager-Van Der Veen, Suzanne M; Port, Andreas; Geurts, T B Paul

    2005-05-01

    The pharmacokinetics of nandrolone in serum and urine were investigated in healthy young men after a single im injection of 50 mg (n = 20), 100 mg (n = 17), or 150 mg (n = 17) nandrolone decanoate. Blood samples were collected before treatment and for up to 32 d after dosing. In addition, in the 50- and 150-mg groups, 24-h urine samples were collected before treatment and on d 1, 7, and 33 after treatment; in the 150-mg group, additional samples were collected after 3 and 6 months. Serum concentrations and the area under the curve of nandrolone increased proportionally with the dose administered. The peak serum concentration ranged from 2.14 ng/ml in the 50-mg group to 4.26 ng/ml in the 100-mg group and 5.16 ng/ml in the 150-mg group. The peak serum concentration was reached after 30 h (50 and 100 mg) and 72 h (150 mg), whereas the terminal half-life was 7-12 d. In urine, pretreatment concentrations of 19-norandrosterone (19-NA) and/or 19-noretiocholanolone (19-NE) were detected in five of 37 subjects (14%). In the 50-mg group, 19-NA and/or 19-NE could be detected at least until 33 d after injection in 16 of 17 subjects (94%). In the 150-mg group, who were presumed to have not previously used nandrolone, nandrolone metabolites could be detected for up to 6 months in eight of 12 subjects (67%) for 19-NE and in 10 of 12 subjects (83%) for 19-NA.

  9. Cobinamide-Based Cyanide Analysis by Multiwavelength Spectrometry in a Liquid Core Waveguide

    PubMed Central

    Ma, Jian; Dasgupta, Purnendu K.; Blackledge, William; Boss, Gerry R.

    2010-01-01

    A novel cyanide analyzer based on sensitive cobinamide chemistry relies on simultaneous reagent and sample injection and detection in a 50 cm liquid core waveguide (LCW) flow cell illuminated by a white light emitting diode. The transmitted light is read by a fiber-optic charge coupled device (CCD) spectrometer. Alkaline cobinamide (orange, λmax = 510 nm) changes to violet (λmax = 583 nm) upon reaction with cyanide. Multiwavelength detection permits built-in correction for artifact responses intrinsic to a single-line flow injection system and corrects for drift. With optimum choice of the reaction medium, flow rate, and mixing coil length, the limit of detection (LOD, S/N = 3) is 30 nM and the linear dynamic range extends to 10 μM. The response base width for 1% carryover is <95 s, permitting a throughput of 38 samples/h. The relative standard deviations (rsd) for repetitive determinations at 0.15, 0.5, and 1 μM were 7.6% (n = 5), 3.2% (n = 7), and 1.7% (n = 6), respectively. Common ions at 250–80 000× concentrations do not interfere except for sulfide. For the determination of 2 μM CN−, the presence of 2, 5, 10, 20, 100, and 1000 μM HS− results in 22, 27, 48, 58, 88, and 154% overestimation of cyanide. The sulfide product actually has a different characteristic absorption, and in those samples where significant presence is likely, this can be corrected for. We demonstrate applicability by analyzing the hydrolytic cyanide extract of apple and pear seeds with orange seeds as control and also measure HCN in breath air samples. Spike recoveries in these sample extracts ranged from 91 to 108%. PMID:20560532

  10. Mixing problems in using indicators for measuring regional blood flow

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ushioda, E.; Nuwayhid, B.; Tabsh, K.

    A basic requirement for using indicators for measuring blood flow is adequate mixing of the indicator with blood prior to sampling the site. This requirement has been met by depositing the indicator in the heart and sampling from an artery. Recently, authors have injected microspheres into veins and sampled from venous sites. The present studies were designed to investigate the mixing problems in sheep and rabbits by means of Cardio-Green and labeled microspheres. The indicators were injected at different points in the circulatory system, and blood was sampled at different levels of the venous and arterial systems. Results show themore » following: (a) When an indicator of small molecular size (Cardio-Green) is allowed to pass through the heart chambers, adequate mixing is achieved, yielding accurate and reproducible results. (b) When any indicator (Cardio-Green or microspheres) is injected into veins, and sampling is done at any point in the venous system, mixing is inadequate, yielding flow results which are inconsistent and erratic. (c) For an indicator or large molecular size (microspheres), injecting into the left side of the heart and sampling from arterial sites yield accurate and reproducible results regardless of whether blood is sampled continuously or intermittently.« less

  11. Modulation response characteristics of optical injection-locked cascaded microring laser

    NASA Astrophysics Data System (ADS)

    Yu, Shaowei; Pei, Li; Liu, Chao; Wang, Yiqun; Weng, Sijun

    2014-09-01

    Modulation bandwidth and frequency chirping of the optical injection-locked (OIL) microring laser (MRL) in the cascaded configuration are investigated. The unidirectional operation of the MRL under strong injection allows simple and cost-saving monolithic integration of the OIL system on one chip as it does not need the use of isolators between the master and slave lasers. Two cascading schemes are discussed in detail by focusing on the tailorable modulation response. The chip-to-power ratio of the cascaded optical injection-locked configuration has decreased by up to two orders of magnitude, compared with the single optical injection-locked configuration.

  12. Bolus dose response characteristics of single chain urokinase plasminogen activator and tissue plasminogen activator in a dog model of arterial thrombosis.

    PubMed

    Badylak, S F; Voytik, S; Klabunde, R E; Henkin, J; Leski, M

    1988-11-15

    Tissue plasminogen activator (t-PA) and single chain urokinase-plasminogen activator (scu-PA) are relatively "fibrin-specific" thrombolytic drugs with short plasma half lives of 6-8 minutes. Most treatment regimens with these agents utilize a bolus injection followed by continuous drug infusion, usually combined with anticoagulant therapy. The purpose of this study was to establish the dose-response characteristics for scu-PA and t-PA, when given as a single intravenous bolus injection, in a dog model of arterial thrombosis. Eight groups of 6 dogs each were given one of the following doses of scu-PA (mg/kg): 0.20, 0.50, 1.00, 2.00; or t-PA: 0.05, 0.10, 0.20; or an equivalent amount of saline (control group). All doses were given as a single bolus injection 60 minutes after formation of a totally occlusive femoral artery thrombus. Thrombolysis was measured by monitoring the continuous decrement of 125I activity from a radiolabelled thrombus. Ninety minutes after drug injection, all scu-PA treated dogs showed greater thrombolysis (30%, 45%, 56%, and 67%, respectively) than the control group (15%, p less than 0.01). The 0.10 and 0.20 mg/kg t-PA treated dogs showed greater thrombolysis (35% and 49%, respectively) than the control group (15%, p less than 0.01). Both scu-PA and t-PA caused a partial and dose-dependent decrease in alpha 2-antiplasmin activity but scu-PA caused a greater depletion (72% vs. 18%, respectively, p less than 0.05) at 60 minutes after the highest dose of drug administration. Both drugs showed a longer than expected thrombolytic effect based upon the known half lives. Neither drug caused significant changes in the prothrombin time, activated partial thromboplastin time, thrombin time, hematocrit, platelet count, or fibrin degradation product concentration. Single bolus injections of scu-PA and t-PA produce safe and effective thrombolysis in this dog model of arterial thrombosis.

  13. Single-injection femoral nerve block. Effects on the independence level in functional activities in the early postoperative period in patients with total knee arthroplasty.

    PubMed

    Tugay, Nazan; Saricaoglu, Fatma; Satilmis, Tulin; Alpar, Ulku; Akarcali, Inci; Citaker, Seyit; Tugay, Umut; Atilla, Bulent; Tokgozoglu, Mazhar

    2006-07-01

    To investigate the efficacy of single injection femoral nerve block (FNB) on the independence level in functional activities in the early postoperative period in patients with total knee arthroplasty (TKA). We conducted this prospective, randomized, blinded trial in the Department of Orthopedics and Traumatology, Hacettepe University Hospital Ankara, Turkey, between June 2003 and April 2004. Twenty-three patients scheduled for elective TKA were randomly divided into 3 groups. Group I received preemptive single injection FNB, group II received postoperative single injection FNB, and group III served as a control group. Intravenous morphine patient controlled analgesia (PCA) was used following surgery in all groups. Morphine dose and pain score defined by the visual analog scale (VAS) were recorded postoperatively at the 15th minute, 30th minute, 1st, 4th, 6th, 12th, 24th, and 48th hours. A standard rehabilitation protocol was applied for all patients. The independence level in functional activities was assessed during the first 2 postoperative days and at discharge with the Iowa Level of Assistance Scale (ILAS) and the Iowa Ambulation Speed Scale (IASS). Physical therapists that enrolled in the study were blinded to the groups. Pain scores were significantly different between the groups (p<0.05). The preemptive and postoperative FNB group`s VAS scores were both significantly lower than the control group (p<0.05). However, there was no significant difference in VAS scores between preemptive and postoperative FNB groups (p>0.05). There was no statistically significant difference between the groups in any of the functional scores in the first 2 postoperative days, and at discharge (p>0.05). Single injection FNB provided effective analgesia in patients undergoing TKA. However, the independence level in functional activities in the early postoperative period was not influenced by the analgesia method.

  14. External and Intraparticle Diffusion of Coumarin 102 with Surfactant in the ODS-silica Gel/water System by Single Microparticle Injection and Confocal Fluorescence Microspectroscopy.

    PubMed

    Nakatani, Kiyoharu; Matsuta, Emi

    2015-01-01

    The release mechanism of coumarin 102 from a single ODS-silica gel microparticle into the water phase in the presence of Triton X-100 was investigated by confocal fluorescence microspectroscopy combined with the single microparticle injection technique. The release rate significantly depended on the Triton X-100 concentration in the water phase and was not limited by diffusion in the pores of the microparticle. The release rate constant was inversely proportional to the microparticle radius squared, indicating that the rate-determining step is the external diffusion between the microparticle and the water phase.

  15. Ultra-performance liquid chromatography/tandem mass spectrometric quantification of structurally diverse drug mixtures using an ESI-APCI multimode ionization source.

    PubMed

    Yu, Kate; Di, Li; Kerns, Edward; Li, Susan Q; Alden, Peter; Plumb, Robert S

    2007-01-01

    We report in this paper an ultra-performance liquid chromatography/tandem mass spectrometric (UPLC(R)/MS/MS) method utilizing an ESI-APCI multimode ionization source to quantify structurally diverse analytes. Eight commercial drugs were used as test compounds. Each LC injection was completed in 1 min using a UPLC system coupled with MS/MS multiple reaction monitoring (MRM) detection. Results from three separate sets of experiments are reported. In the first set of experiments, the eight test compounds were analyzed as a single mixture. The mass spectrometer was switching rapidly among four ionization modes (ESI+, ESI-, APCI-, and APCI+) during an LC run. Approximately 8-10 data points were collected across each LC peak. This was insufficient for a quantitative analysis. In the second set of experiments, four compounds were analyzed as a single mixture. The mass spectrometer was switching rapidly among four ionization modes during an LC run. Approximately 15 data points were obtained for each LC peak. Quantification results were obtained with a limit of detection (LOD) as low as 0.01 ng/mL. For the third set of experiments, the eight test compounds were analyzed as a batch. During each LC injection, a single compound was analyzed. The mass spectrometer was detecting at a particular ionization mode during each LC injection. More than 20 data points were obtained for each LC peak. Quantification results were also obtained. This single-compound analytical method was applied to a microsomal stability test. Compared with a typical HPLC method currently used for the microsomal stability test, the injection-to-injection cycle time was reduced to 1.5 min (UPLC method) from 3.5 min (HPLC method). The microsome stability results were comparable with those obtained by traditional HPLC/MS/MS.

  16. Single dose intratympanic mesna application inhibits propylene glycol induced cholesteatoma formation.

    PubMed

    Ismi, O; Karabulut, Y Y; Bal, K K; Vayisoglu, Y; Unal, M

    2017-03-01

    Mesna (i.e. sodium 2-mercaptoethanesulfonate; C2H5NaO3S2) has been used in otological surgery such as cholesteatoma dissection and tympanic membrane lateralisation in atelectatic ears. However, this study aimed to investigate its effect on cholesteatoma formation. A total of 20 Wistar rats were divided into two groups of 10 animals. The right and left ears of control animals were treated with saline (saline control group; n = 10 ears) and propylene glycol plus saline (propylene glycol control group; n = 10 ears), respectively. In the mesna group, both ears were treated with propylene glycol plus mesna (n = 20 ears). On days 1, 8 and 15, the saline control group had intratympanic injections of 0.2 ml saline and the propylene glycol control and mesna groups had intratympanic injections of 0.2 ml 100 per cent propylene glycol. On day 22, the propylene glycol control group had a single intratympanic injection of 0.2 ml saline and the mesna group had a single intratympanic injection of 10 per cent mesna. Animals were killed 12 weeks after the last injection and the temporal bones were sent for histopathological evaluation. The cholesteatoma formation rate was 88 per cent in the propylene glycol control group, but was significantly lower in the mesna group (p = 0.01). There were no significant differences in granulation tissue formation (p = 0.498), cyst formation in the bulla (p = 0.381), fibrosis (p = 0.072) and epithelial hyperplasia (p = 0.081) among experimental groups. Intratympanic propylene glycol administration is an effective method of promoting experimental cholesteatoma formation. Administration of a single dose of intratympanic mesna inhibited cholesteatoma formation in an animal model.

  17. Easy and Fast Method for the Determination of Biogenic Amines in Fish and Fish Products with Liquid Chromatography Coupled to Orbitrap Tandem Mass Spectrometry.

    PubMed

    Kaufmann, Anton; Maden, Kathryn

    2018-03-01

    A quantitative method for the determination of biogenic amines was developed. The method is characterized by the virtual absence of sample cleanup and does not require a derivatization reaction. Diluted extracts are centrifuged, filtrated, and directly injected into an ultra-HPLC column, which is coupled to a single-stage high-resolution mass spectrometer (Orbitrap). The chromatography is based on a reversed-phase column and an eluent containing an ion-pairing agent (heptafluorobutyric acid). The high sensitivity of the instrument permits the injection of very diluted extracts, which ensures stable retention times and the virtual absence of signal suppression effects. In addition, the quantification of histamine (a regulated compound) is further aided by the use of an isotopically labeled internal standard. The method was validated for three fish-based matrixes. Both the sample processing and the analytical measurement are very fast; hence, the methodology is ideal for high-throughput work. In addition, the method is significantly more selective than conventional methods (i.e., derivatization followed by LC with UV/fluorescence (FL) detection) for biogenic amines. A comparison showed that LC-UV/FL methods can produce false-positive findings due to coeluting matrix compounds.

  18. Ultrasound extracted flavonoids from four varieties of Portuguese red grape skins determined by reverse-phase high-performance liquid chromatography with electrochemical detection.

    PubMed

    Novak, Ivana; Janeiro, Patricia; Seruga, Marijan; Oliveira-Brett, Ana Maria

    2008-12-23

    Several flavonoids present in red grape skins from four varieties of Portuguese grapes were determined by reverse-phase high-performance liquid chromatography (RP-HPLC) with electrochemical detection (ECD). Extraction of flavonoids from red grape skins was performed by ultrasonication, and hydrochloric acid in methanol was used as extraction solvent. The developed RP-HPLC method used combined isocratic and gradient elution with amperometric detection with a glassy carbon-working electrode. Good peak resolution was obtained following direct injection of a sample of red grape extract in a pH 2.20 mobile phase. Eleven different flavonoids: cyanidin-3-O-glucoside (kuromanin), delphinidin-3-O-glucoside (myrtillin), petunidin-3-O-glucoside, peonidin-3-O-glucoside, malvidin-3-O-glucoside (oenin), (+)-catechin, rutin, fisetin, myricetin, morin and quercetin, can be separated in a single run by direct injection of sample solution. The limit of detection obtained for these compounds by ECD was 20-90 pg/L, 1000 times lower when compared with photodiode array (PDA) limit of detection of 12-55 ng/L. RP-HPLC-ECD was characterized by an excellent sensitivity and selectivity, and appropriate for the simultaneous determination of these electroactive phenolic compounds present in red grape skins.

  19. The genotoxic effect of oxcarbazepine on mice blood lymphocytes.

    PubMed

    Akbar, Huma; Khan, Ajmal; Mohammadzai, Imdadullah; Khisroon, Muhammad; Begum, Ilham

    2018-04-01

    This study was conducted to assess the amount of DNA damage caused by Oxcarbazepine (OXC) through single cell gel electrophoresis (SCGE) technique/comet assay. OXC derived from dibenzazepine series is an effective second generation antiepileptic drug (AED) for both children and adults. Side effects like genotoxic effects of AEDs are of prime importance resulting from toxic metabolites, free radicals and reactive oxygen species (ROS). Forty Eight adult male Bagg's albino mice (BALB/c) were randomly classified into eight groups, each comprising of six animals. Two of these groups were control and six were tested groups. Control groups were injected with 1% tween 80 while tested groups were injected with 10, 20, and 40 mg/kg-day OXC for seven days (acute therapy) and 28 days (subchronic therapy) in peritoneal cavity. Blood samples were collected by cardiac puncture and subjected to comet assay for the analysis of DNA damage. Per sample 100 cells were scored and classified according to comet tail length. The results showed that OXC in acute and long term therapies had significantly higher (p < 0.05) genotoxicity in treated groups as compared to control groups. Our study suggests that OXC may cause significant DNA damage in both acute as well as in subchronic therapies.

  20. [Rapid screening and quality evaluation for the harmful substance 5-hydroxymethyl furfural in commercially available traditional Chinese medicine injection using LC-MS/MS method].

    PubMed

    Zang, Qing-ce; He, Jing-jing; Bai, Jin-fa; Zheng, Ya-jie; Zhang, Rui-ping; Li, Tie-gang; Wang, Zhong-hua; He, Jiu-ming; Abliz, Zeper

    2013-11-01

    To screen the harmful substance 5-hydroxymethyl furfural content in commercially available traditional Chinese medicine injection which are commonly used, and to preliminarily evaluate the quality of these injections, 5-hydroxymethyl furfural was taken as an index. The contents of 5-hydroxymethyl furfural in 56 samples which consist of 23 kinds of traditional Chinese medicine injections and glucose injection were determined using LC-MS/MS, and 5-hydroxymethyl furfural was detected in 52 of these samples. The minimal content was 0.0038 microg x L(-1) and the maximum content was 1420 microg x mL(-1). The contents of 5-hydroxymethyl furfural were significantly different in traditional Chinese medicine injection which came from different kinds, manufacturers or batches. The results showed the quality difference of commercially available traditional Chinese medicine injection is significant taking 5-hydroxymethyl furfural content as assessment index. More attention should be paid to the safety of 5-hydroxymethyl furfural in traditional Chinese medicine injection, and unified limitation standard should be set to improve medication safety of traditional Chinese medicine injection.

  1. Experimental Investigation on Dilation Mechanisms of Land-Facies Karamay Oil Sand Reservoirs under Water Injection

    NASA Astrophysics Data System (ADS)

    Lin, Botao; Jin, Yan; Pang, Huiwen; Cerato, Amy B.

    2016-04-01

    The success of steam-assisted gravity drainage (SAGD) is strongly dependent on the formation of a homogeneous and highly permeable zone in the land-facies Karamay oil sand reservoirs. To accomplish this, hydraulic fracturing is applied through controlled water injection to a pair of horizontal wells to create a dilation zone between the dual wells. The mechanical response of the reservoirs during this injection process, however, has remained unclear for the land-facies oil sand that has a loosely packed structure. This research conducted triaxial, permeability and scanning electron microscopy (SEM) tests on the field-collected oil sand samples. The tests evaluated the influences of the field temperature, confining stress and injection pressure on the dilation mechanisms as shear dilation and tensile parting during injection. To account for petrophysical heterogeneity, five reservoir rocks including regular oil sand, mud-rich oil sand, bitumen-rich oil sand, mudstone and sandstone were investigated. It was found that the permeability evolution in the oil sand samples subjected to shear dilation closely followed the porosity and microcrack evolutions in the shear bands. In contrast, the mudstone and sandstone samples developed distinct shear planes, which formed preferred permeation paths. Tensile parting expanded the pore space and increased the permeability of all the samples in various degrees. Based on this analysis, it is concluded that the range of injection propagation in the pay zone determines the overall quality of hydraulic fracturing, while the injection pressure must be carefully controlled. A region in a reservoir has little dilation upon injection if it remains unsaturated. Moreover, a cooling of the injected water can strengthen the dilation potential of a reservoir. Finally, it is suggested that the numerical modeling of water injection in the Karamay oil sand reservoirs must take into account the volumetric plastic strain in hydrostatic loading.

  2. Three-Dimensional Changes in the Midface Following Malar Calcium Hydroxyapatite Injection in a Cadaver Model.

    PubMed

    Gatherwright, James R; Brown, Matthew S; Katira, Kristopher M; Rowe, David J

    2015-08-01

    Three-dimensional (3D) changes in the midface following malar calcium hydroxyapatite (CaHa) injection have not been systematically analyzed. The authors analyzed 3D volume changes in midface and naso-labial fold (NLF) volume, as well as lateral movement in the NLF/naso-labial crease (NLC) junction following malar injection of CaHa in a cadaver model. A single surgeon injected CaHa in the supraperiosteal plane. Sequential images were obtained with the VECTRA 3D system pre- and post-1.5- and 3-cc CaHa injections. All measurements were performed by a single examiner. Injection location was verified anatomically. Injections were performed in 16 fresh cadaver hemi-faces. Maximal increases in projection were centered on the malar injection site, with associated decreases in projection and volume in the infero-medial locations. Relative mean increases in volume of 3.16 cc and 4.94 cc were observed following the 1.5-cc and 3-cc injections, respectively. There was a relative decrease in the volume of the NLF of -0.3 cc and -0.4 cc following the 1.5- and 3-cc injections, respectively. Injection of CaHa was associated with lateral movements of the NLF-NLC junction at the level of the nasal sill, philtral columns, and oral commissure, measuring 2.7, 2.5, and 1.9 mm and 2.8, 2.9, and 2.4 mm following the 1.5- and 3-cc injections, respectively. Anatomical dissection verified the location in the supraperiosteal space and within the middle malar fat pad. Following malar CaHa injection, 3D photographic analysis showed a measureable lifting effect with recruitment of ptotic tissue and lateral movement of the NLF-NLC junction in a cadaver model. © 2015 The American Society for Aesthetic Plastic Surgery, Inc. Reprints and permission: journals.permissions@oup.com.

  3. Pharmacokinetics of subcutaneous versus intramuscular administration of ceftiofur crystalline-free acid to bearded dragons (Pogona vitticeps).

    PubMed

    Churgin, Sarah M; Musgrave, Kari E; Cox, Sherry K; Sladky, Kurt K

    2014-05-01

    To compare pharmacokinetics after a single IM or SC injection of ceftiofur crystalline-free acid (CCFA) to bearded dragons (Pogona vitticeps). 8 adult male bearded dragons. In a preliminary experiment, doses of 15 and 30 mg/kg, SC, were compared in 2 animals, and 30 mg/kg resulted in a more desirable pharmacokinetic profile. Then, in a randomized, complete crossover experimental design, each bearded dragon (n = 6) received a single dose of 30 mg of CCFA/kg IM or SC; the experiment was repeated after a 28-day washout period with the other route of administration. Blood samples were collected at 10 time points for 288 hours after injection. Plasma concentrations of ceftiofur and desfuroylceftiofur metabolites were measured via reverse-phase high-performance liquid chromatography. Data were analyzed with a noncompartmental model. No adverse effects were observed. Plasma concentrations greater than a target minimum inhibitory concentration of 1 μg/mL were achieved by 4 hours after administration by both routes. Mean plasma concentrations remained > 1 μg/mL for > 288 hours for both routes of administration. A single dose of CCFA (30 mg/kg) administered IM or SC to bearded dragons yielded plasma concentrations of ceftiofur and its metabolites > 1 μg/mL for > 288 hours. The SC route would be preferred because of less variability in plasma concentrations and greater ease of administration than the IM route. Future studies should include efficacy data as well as evaluation of the administration of multiple doses.

  4. Relationship Between the Provision of Injection Services in Ambulatory Physician Offices and Prescribing Injectable Medicines.

    PubMed

    Yousefi, Naeimeh; Rashidian, Arash; Soleymani, Fatemeh; Kebriaeezade, Abbas

    2017-01-01

    Overuse of injections is a common problem in many low-income and middle income countries. While cultural factors and attitudes of both physicians and patients are important factors, physicians› financial intensives may play an important role in overprescribing of injections. This study was designed to assess the effects of providing injection- services in physicians› ambulatory offices on prescribing injectable medicines. This cross-sectional study was conducted in Tehran in 2012 -2013and included a random sample of general physicians, pediatricians and infectious disease specialists. We collected data on the provision of injection services in or in proximity of physician offices, and obtained data from physicians› prescriptions in the previous three-month period. We analyzed the data using ANOVA, Student›s t-test and linear regression methods. We obtained complete data from 465 of 600 sampled physicians. Overall 41.9% of prescriptions contained injectable medicines. 75% of physicians offered injection services in their offices. Male physicians and general physicians were more likely to offer the services, and more likely to prescribe injectables. We observed a clear linear relationship between the injection service working hours and the proportion of prescriptions containing injectables (p-value<0.001). Providing injection service in the office was directly linked with the proportion of prescriptions containing injectables. While provision of injection services may provide a direct financial benefit to physicians, it is unlikely to be able to substantially reduce injectable medicines› prescription without addressing the issue.

  5. Pseudolinear gradient ultrahigh-pressure liquid chromatography using an injection valve assembly.

    PubMed

    Xiang, Yanqiao; Liu, Yansheng; Stearns, Stanley D; Plistil, Alex; Brisbin, Martin P; Lee, Milton L

    2006-02-01

    The use of ultrahigh pressures in liquid chromatography (UHPLC) imposes stringent requirements on hardware such as pumps, valves, injectors, connecting tubing, and columns. One of the most difficult components of the UHPLC system to develop has been the sample injector. Static-split injection, which can be performed at pressures up to 6900 bar (100,000 psi), consumes a large sample volume and is very irreproducible. A pressure-balanced injection valve provided better reproducibility, shorter injection time, reduced sample consumption, and greater ease of use; however, it could only withstand pressures up to approximately 1000 bar (15,000 psi). In this study, a new injection valve assembly that can operate at pressures as high as 2070 bar (30,000 psi) was evaluated for UHPLC. This assembly contains six miniature electronically controlled needle valves to provide accurate and precise volumes for introduction into the capillary LC column. It was found that sample volumes as small as several tenths of a nanoliter can be injected, which are comparable to the results obtained from the static-split injector. The reproducibilities of retention time, efficiency, and peak area were investigated, and the results showed that the relative standard deviations of these parameters were small enough for quantitative analyses. Separation experiments using the UHPLC system with this new injection valve assembly showed that this new injector is suitable for both isocratic and gradient operation modes. A newly designed capillary connector was used at a pressure as high as 2070 bar (30,000 psi).

  6. Anisotropic mechanical behavior of an injection molded short fiber reinforced thermoplastic

    NASA Astrophysics Data System (ADS)

    Lopez, Delphine; Thuillier, Sandrine; Bessières, Nicolas; Grohens, Yves

    2016-10-01

    A short fiber reinforced thermoplastic was injected into a rectangular mold, in order to prepare samples to characterize the mechanical behavior of the material. The injection process was simulated with Moldflow and a cutting pattern was deduced from the predicted fiber orientation, leading to samples with several well-defined orientations with respect to the injection direction. Monotonic tensile tests up to rupture, as well as complex cycles made of loading steps followed by relaxation steps at different strain levels were performed, in order to check the reproducibility for a given orientation. Moreover, the fiber orientation in the central part of the tensile samples was also analyzed with X-ray tomography. The results show that the mechanical behavior for each orientation (among 6) was rather reproducible, thus validating the cutting pattern.

  7. Continuous-Wave Single-Frequency Operation of Fabry-Perot Laser Diodes by Self-Injection Phase Locking Using Feedback from a Fiber Bragg Grating

    NASA Technical Reports Server (NTRS)

    Duerksen, Gary L.; Krainak, Michael A.

    1998-01-01

    Single-frequency operation of uncoated Fabry-Perot laser diodes is demonstrated by phase- locking the laser oscillations through self-injection seeding with feedback from a fiber Bragg grating. By precisely tuning the laser temperature so that an axial-mode coincides with the short-wavelength band edge of the grating, the phase of the feedback is made conjugate to that of the axial mode, locking the phase of the laser oscillations to that mode.

  8. Engine with hydraulic fuel injection and ABS circuit using a single high pressure pump

    DOEpatents

    Bartley, Bradley E.; Blass, James R.; Gibson, Dennis H.

    2001-01-01

    An engine system comprises a hydraulically actuated fuel injection system and an ABS circuit connected via a fluid flow passage that provides hydraulic fluid to both the fuel injection system and to the ABS circuit. The hydraulically actuated system includes a high pressure pump. The fluid control passage is in fluid communication with an outlet from the high pressure pump.

  9. Multiple injection mode with or without repeated sample injections: Strategies to enhance productivity in countercurrent chromatography.

    PubMed

    Müller, Marco; Wasmer, Katharina; Vetter, Walter

    2018-06-29

    Countercurrent chromatography (CCC) is an all liquid based separation technique typically used for the isolation and purification of natural compounds. The simplicity of the method makes it easy to scale up CCC separations from analytical to preparative and even industrial scale. However, scale-up of CCC separations requires two different instruments with varying coil dimensions. Here we developed two variants of the CCC multiple injection mode as an alternative to increase the throughput and enhance productivity of a CCC separation when using only one instrument. The concept is based on the parallel injection of samples at different points in the CCC column system and the simultaneous separation using one pump only. The wiring of the CCC setup was modified by the insertion of a 6-port selection valve, multiple T-pieces and sample loops. Furthermore, the introduction of storage sample loops enabled the CCC system to be used with repeated injection cycles. Setup and advantages of both multiple injection modes were shown by the isolation of the furan fatty acid 11-(3,4-dimethyl-5-pentylfuran-2-yl)-undecanoic acid (11D5-EE) from an ethyl ester oil rich in 4,7,10,13,16,19-docosahexaenoic acid (DHA-EE). 11D5-EE was enriched in one step from 1.9% to 99% purity. The solvent consumption per isolated amount of analyte could be reduced by ∼40% compared to increased throughput CCC and by ∼5% in the repeated multiple injection mode which also facilitated the isolation of the major compound (DHA-EE) in the sample. Copyright © 2018 Elsevier B.V. All rights reserved.

  10. Plasma discharge elemental detector for a mass spectrometer

    NASA Astrophysics Data System (ADS)

    Heppner, R. A.

    1983-06-01

    A material to be analyzed is injected into a mirowave-induced plasma discharge unit, in which the material is carried with a flow of buffer gas through an intense microwave energy field which produces a plasma discharge in the buffer gas. As the material exits from the plasma discharge, the material is sampled and conveyed along a capillary transfer tube to a mass spectrometer where it is analyzed. The plasma discharge causes dissociation of complex organic molecules into simpler molecules which return to the neutral ground state before they are analyzed in the mass spectrometer. The buffer gas is supplied to one end portion of the discharge tube and is withdrawn from the other end portion by a vacuum pump which maintains a subatmospheric pressure in the discharge tube. The sample material is injected by a capillary injection tube into the buffer gas flow as it enters the plasma discharge zone. The dissociated materials are sampled by an axial sampling tube having an entrance where the buffer gas exits from the plasma discharge zone. The sample material may be supplied by a gas chromatography having a capillary effluent line connected to the capillary injection tube, so that the effluent material is injected into the microwave induced plasma discharge. The microwave field is produced by a cavity resonator through which the discharge tube passes.

  11. CO2 Push-Pull Single Fault Injection Simulations

    DOE Data Explorer

    Borgia, Andrea; Oldenburg, Curtis (ORCID:0000000201326016); Zhang, Rui; Pan, Lehua; Daley, Thomas M.; Finsterle, Stefan; Ramakrishnan, T.S.; Doughty, Christine; Jung, Yoojin; Lee, Kyung Jae; Altundas, Bilgin; Chugunov, Nikita

    2017-09-21

    ASCII text files containing grid-block name, X-Y-Z location, and multiple parameters from TOUGH2 simulation output of CO2 injection into an idealized single fault representing a dipping normal fault at the Desert Peak geothermal field (readable by GMS). The fault is composed of a damage zone, a fault gouge and a slip plane. The runs are described in detail in the following: Borgia A., Oldenburg C.M., Zhang R., Jung Y., Lee K.J., Doughty C., Daley T.M., Chugunov N., Altundas B, Ramakrishnan T.S., 2017. Carbon Dioxide Injection for Enhanced Characterization of Faults and Fractures in Geothermal Systems. Proceedings of the 42st Workshop on Geothermal Reservoir Engineering, Stanford University, Stanford, California, February 13-17.

  12. Botulinum toxin type a injections to salivary glands: combination with single event multilevel chemoneurolysis in 2 children with severe spastic quadriplegic cerebral palsy.

    PubMed

    Kim, Heakyung; Lee, Yung; Weiner, Daniel; Kaye, Robin; Cahill, Anne Marie; Yudkoff, Marc

    2006-01-01

    We describe 2 children with severe spastic quadriplegic cerebral palsy (CP) who have significant drooling and frequent aspiration pneumonia. They underwent simultaneous botulinum toxin type A (BTX-A) injections to salivary glands for drooling and prevention of aspiration pneumonia along with single-event multilevel chemoneurolysis (SEMLC) with BTX-A and 5% phenol for severe diffuse spasticity. There was significant improvement in drooling, frequency of aspiration pneumonia, and spasticity without adverse effect. BTX-A injections into the salivary glands, in addition to SEMLC, for these 2 children with medically complicated severe spastic quadriplegic CP, were safe and highly successful procedures, which improved their health-related quality of life.

  13. One-Step Coal Liquefaction

    NASA Technical Reports Server (NTRS)

    Qader, S. A.

    1984-01-01

    Steam injection improves yield and quality of product. Single step process for liquefying coal increases liquid yield and reduces hydrogen consumption. Principal difference between this and earlier processes includes injection of steam into reactor. Steam lowers viscosity of liquid product, so further upgrading unnecessary.

  14. Liposomal bupivacaine as a single-injection peripheral nerve block: a dose-response study.

    PubMed

    Ilfeld, Brian M; Malhotra, Nisha; Furnish, Timothy J; Donohue, Michael C; Madison, Sarah J

    2013-11-01

    Currently available local anesthetics approved for single-injection peripheral nerve blocks have a maximum duration of <24 hours. A liposomal bupivacaine formulation (EXPAREL, Pacira Pharmaceuticals, Inc., San Diego, CA), releasing bupivacaine over 96 hours, recently gained Food and Drug Administration approval exclusively for wound infiltration but not peripheral nerve blocks. Bilateral single-injection femoral nerve blocks were administered in healthy volunteers (n = 14). For each block, liposomal bupivacaine (0-80 mg) was mixed with normal saline to produce 30 mL of study fluid. Each subject received 2 different doses, 1 on each side, applied randomly in a double-masked fashion. The end points included the maximum voluntary isometric contraction (MVIC) of the quadriceps femoris muscle and tolerance to cutaneous electrical current in the femoral nerve distribution. Measurements were performed from baseline until quadriceps MVIC returned to 80% of baseline bilaterally. There were statistically significant dose responses in MVIC (0.09%/mg, SE = 0.03, 95% confidence interval [CI], 0.04-0.14, P = 0.002) and tolerance to cutaneous current (-0.03 mA/mg, SE = 0.01, 95% CI, -0.04 to -0.02, P < 0.001), however, in the opposite direction than expected (the higher the dose, the lower the observed effect). This inverse relationship is biologically implausible and most likely due to the limited sample size and the subjective nature of the measurement instruments. While peak effects occurred within 24 hours after block administration in 75% of cases (95% CI, 43%-93%), block duration usually lasted much longer: for bupivacaine doses >40 mg, tolerance to cutaneous current did not return to within 20% above baseline until after 24 hours in 100% of subjects (95% CI, 56%-100%). MVIC did not consistently return to within 20% of baseline until after 24 hours in 90% of subjects (95% CI, 54%-100%). Motor block duration was not correlated with bupivacaine dose (0.06 hour/mg, SE = 0.14, 95% CI, -0.27 to 0.39, P = 0.707). The results of this investigation suggest that deposition of a liposomal bupivacaine formulation adjacent to the femoral nerve results in a partial sensory and motor block of >24 hours for the highest doses examined. However, the high variability of block magnitude among subjects and inverse relationship of dose and response magnitude attests to the need for a phase 3 study with a far larger sample size, and that these results should be viewed as suggestive, requiring confirmation in a future trial.

  15. Liposomal Bupivacaine as a Single-Injection Peripheral Nerve Block: A Dose-Response Study

    PubMed Central

    Ilfeld, Brian M.; Malhotra, Nisha; Furnish, Timothy J.; Donohue, Michael C.; Madison, Sarah J.

    2013-01-01

    Background Currently available local anesthetics approved for single-injection peripheral nerve blocks have a maximum duration less than 24 hours. A liposomal bupivacaine formulation (EXPAREL®, Pacira Pharmaceuticals, Inc., San Diego, California), releasing bupivacaine over 96 hours, recently gained Food and Drug Administration approval exclusively for wound infiltration, but not peripheral nerve blocks. Methods Bilateral single-injection femoral nerve blocks were administered in healthy volunteers (n=14). For each block, liposomal bupivacaine (0–80 mg) was mixed with normal saline to produce 30 mL of study fluid. Each subject received two different doses, one on each side, applied randomly in a double-masked fashion. The end points included the maximum voluntary isometric contraction (MVIC) of the quadriceps femoris muscle and tolerance to cutaneous electrical current in the femoral nerve distribution. Measurements were performed from baseline until quadriceps MVIC returned to 80% of baseline bilaterally. Results There were statistically significant dose responses in MVIC (0.09% / mg, SE = 0.03, 95% CI 0.04 to 0.14, p = 0.002) and tolerance to cutaneous current (−0.03 mA / mg, SE = 0.01, 95% CI −0.04 to 0.02, p < 0.001), however, in the opposite direction than expected (the higher the dose, the lower the observed effect). This inverse relationship is biologically implausible, and most likely due to the limited sample size and the subjective nature of the measurement instruments. While peak effects occurred within 24 hours after block administration in 75% of cases (95% CI 43 to 93%), block duration usually lasted much longer: for bupivacaine doses above 40 mg, tolerance to cutaneous current did not return to within 20% above baseline until after 24 h in 100% of subjects (95% CI 56 to 100). MVIC did not consistently return to within 20% of baseline until after 24 hours in 90% of subjects (95% CI 54 to 100%). Motor block duration was not correlated with bupivacaine dose (0.06 h/mg, SE = 0.14, 95% CI −0.27 to 0.39, p = 0.707). Conclusions The results of this investigation suggest that deposition of a liposomal bupivacaine formulation adjacent to the femoral nerve results in a partial sensory and motor block of more than 24 hours for the highest doses examined. However, the high variability of block magnitude among subjects and inverse relationship of dose and response magnitude attests to the need for a Phase 3 study with a far larger sample size, and these results should be viewed as suggestive, requiring confirmation in a future trial. PMID:24108252

  16. 5.7  W cw single-frequency laser at 671  nm by single-pass second harmonic generation of a 17.2  W injection-locked 1342  nm Nd : YVO4 ring laser using periodically poled MgO : LiNbO3.

    PubMed

    Koch, Peter; Ruebel, Felix; Bartschke, Juergen; L'huillier, Johannes A

    2015-11-20

    We demonstrate a continuous wave single-frequency laser at 671.1 nm based on a high-power 888 nm pumped Nd:YVO4 ring laser at 1342.2 nm. Unidirectional operation of the fundamental ring laser is achieved with the injection-locking technique. A Nd:YVO4 microchip laser serves as the injecting seed source, providing a tunable single-frequency power of up to 40 mW. The ring laser emits a single-frequency power of 17.2 W with a Gaussian beam profile and a beam propagation factor of M2<1.1. A 60-mm-long periodically poled MgO-doped LiNbO3 crystal is used to generate the second harmonic in a single-pass scheme. Up to 5.7 W at 671.1 nm with a Gaussian shaped beam profile and a beam propagation factor of M2<1.2 are obtained, which is approximately twice the power of previously reported lasers. This work opens possibilities in cold atoms experiments with lithium, allowing the use of larger ensembles in magneto-optical traps or higher diffraction orders in atomic beam interferometers.

  17. Imaging of CO{sub 2} injection during an enhanced-oil-recovery experiment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gritto, Roland; Daley, Thomas M.; Myer, Larry R.

    2003-04-29

    A series of time-lapse seismic cross well and single well experiments were conducted in a diatomite reservoir to monitor the injection of CO{sub 2} into a hydrofracture zone, using P- and S-wave data. During the first phase the set of seismic experiments were conducted after the injection of water into the hydrofrac-zone. The set of seismic experiments was repeated after a time period of 7 months during which CO{sub 2} was injected into the hydrofractured zone. The issues to be addressed ranged from the detectability of the geologic structure in the diatomic reservoir to the detectability of CO{sub 2} withinmore » the hydrofracture. During the pre-injection experiment, the P-wave velocities exhibited relatively low values between 1700-1900 m/s, which decreased to 1600-1800 m/s during the post-injection phase (-5 percent). The analysis of the pre-injection S-wave data revealed slow S-wave velocities between 600-800 m/s, while the post-injection data revealed velocities between 500-700 m/s (-6 percent). These velocity estimates produced high Poisson ratios between 0.36 and 0.46 for this highly porous ({approx} 50 percent) material. Differencing post- and pre-injection data revealed an increase in Poisson ratio of up to 5 percent. Both, velocity and Poisson estimates indicate the dissolution of CO{sub 2} in the liquid phase of the reservoir accompanied by a pore-pressure increase. The results of the cross well experiments were corroborated by single well data and laboratory measurements on core data.« less

  18. Ultrasound-guided steroid tendon sheath injections in juvenile idiopathic arthritis: a 10-year single-center retrospective study.

    PubMed

    Peters, Shannon E; Laxer, Ronald M; Connolly, Bairbre L; Parra, Dimitri A

    2017-04-11

    The aims of this study were to: (a) Identify tendon sheaths most commonly treated with steroid injections in a pediatric patient population with Juvenile Idiopathic Arthritis (JIA); (b) Describe technical aspects of the procedure; (c) Characterize sonographic appearance of tenosynovitis in JIA; (d) Assess agreement between clinical request and sites injected. This was a 10 year single-center retrospective study (May 2006-April 2016) of patients with JIA referred by Rheumatology for ultrasound-guided tendon sheath injections. Patient demographics, clinical referral information, sonographic appearance of the tendon sheaths and technical aspects of the procedure were analyzed. There were 308 procedures of 244 patients (75% female, mean age 9.6 years) who underwent a total of 926 tendon sheath injections. Ankle tendons were most commonly injected (84.9%), specifically the tendon sheaths of tibialis posterior (22.3%), peroneus longus (20%) and brevis (19.7%). The majority of treated sites (91.9%) showed peritendinous fluid and sheath thickening on ultrasound. There were 2 minor intra-procedure complications without sequelae. A good agreement between clinical request and sites injected was observed. Ultrasound-guided tendon sheath injections with steroids are used frequently to treat patients with JIA. It is a safe intervention with a high technical success rate. The ankle region, specifically the medial compartment, is the site most commonly injected in this group of patients. The most common sonographic finding is peritendinous fluid and sheath thickening. These findings might assist clinicians and radiologists to characterize and more effectively manage tenosynovitis in patients with JIA.

  19. Performance Measurements and Mapping of a R-407C Vapor Injection Scroll Compressor

    NASA Astrophysics Data System (ADS)

    Lumpkin, Domenique; Spielbauer, Niklas; Groll, Eckhard

    2017-08-01

    Environmental conditions significantly define the performance of HVAC&R systems. Vapor compression systems in hot climates tend to operate at higher pressure ratios, leading to increased discharge temperatures. Higher discharge temperatures can lead to higher irreversibilities in the compression process, lower specific enthalpies differences across the evaporator, and possibly a reduction in the compressor life due to the breakdown of the oil used for lubrication. To counter these effects, the use of economized, vapor injection compressors is proposed for vapor compression systems in high temperature climates. Such compressors are commercially available for refrigeration applications, in particular, supermarket refrigeration systems. However, compressor maps for vapor injection compressors are limited and none exist for R-407C. Through calorimeter testing, a compressor map for a single-port vapor injection compressor using R-407C was developed. A standard correlation for mapping single-port vapor injection compressors is proposed and validated using the compressor test results. The system and compressor performance with and without vapor injection was considered. As expected, with vapor injection there was a reduction in compressor discharge temperatures and an increase in the system coefficient of performance. The proposed dimensionless correlation is more accurate than the AHRI polynomial for mapping the injection ratio, discharge temperature, and compressor heat loss. The predicted volumetric efficiency values from the dimensionless correlation is within 1% of the measured valued. Similarly, the predicted isentropic efficiency values are within 2% of the measured values.

  20. Liquid chromatography of polymers under limiting conditions of desorption II. Tandem injection and quantitative molar mass determination.

    PubMed

    Snauko, Marián; Berek, Dusan

    2005-11-11

    Liquid chromatography under limiting conditions of desorption (LC LCD) is a method which allows molar mass independent elution of various synthetic polymers. A narrow, slowly moving zone of small molecules, which promotes full adsorption of one kind of polymer species within column (an adsorli) acts as an impermeable barrier for the fast moving macromolecules. The latter accumulate on the barrier edge and elute nearly in total volume of liquid within column. At the same time, transport of less adsorptive macromolecules is not hampered so that these are eluted in the size exclusion (SEC) mode. As result, polymers differing in their polarity and adsorptivity can be easily separated without molar mass interference. Three methods of barrier creation are discussed and compared. It is shown that a fraction of sample may elute unretained if the adsorli sample solvent is used as a barrier in connection with a narrow-pore column packing. One part of excluded macromolecules likely breaks-out from the adsorli zone and this results in partial loss of sample and distortion of the LC LCD peaks. This problem can be avoided if the adsorli zone is injected immediately before sample solution. Applicability of the LC LCD method for polymer separation has been demonstrated with a model mixture of poly(methyl methacrylate) (adsorbing polymer) and polystyrene (non adsorbing polymer) using bare silica gel as a column packing with a combination of tetrahydrofuran (a desorption promoting liquid -a desorli) and toluene (adsorli). It has been shown that the LC LCD procedure with tandem injection allows simple and fast discrimination of polymer blend components with good repeatability and high sample recovery. For quantitative determination of molar masses of both LC LCD and SEC eluted polymers, an additional size exclusion chromatographic column can be applied either in a conventional way or in combination with a multi-angle light scattering detector. A single eluent is used in the latter column, which separates the mixed mobile phase, system peaks and the desorli zone from the polymer peaks so that measurements are free from disturbances caused by the changing eluent composition. The resulting LC LCD x SEC procedure has been successfully applied to poly(methyl methacrylate) samples.

  1. Injection of benomyl into elm, oak & maple

    Treesearch

    Garold F. Gregory; Thomas W. Jones; Percy McWain; Percy McWain

    1971-01-01

    A newly devised apparatus using pressure to inject fluids into trees was used to inject solubilized benomyl into elms, oaks, and maples. In October and November, injections were made into the outer two annual rings of sapwood at points 2 to 3 feet above ground line. One to 3 weeks after injection, the trees were sampled; and positive bioassays were obtained from branch...

  2. Platelet-rich plasma for chronic lateral epicondylitis: is one injection sufficient?

    PubMed

    Glanzmann, Michael C; Audigé, Laurent

    2015-12-01

    Chronic lateral epicondylitis is generally treated using nonsurgical methods including physiotherapy and infiltrations of cortisone or platelet-rich plasma (PRP). The latter is known for its simple application as well as associated low risk of adverse events, which lend to its widespread use in treating various musculoskeletal conditions. There is limited evidence on the effectiveness of PRP injections to optimally treat chronic lateral epicondylitis. This study explored the effectiveness of single or repeated injections for patients with symptoms that spanned 6 months or more and were unresponsive to alternate conservative measures. Patients with chronic lateral epicondylitis received PRP injections in 4-week intervals that were complemented with standardized physical therapy. Patient-reported outcomes based on the patient-rated elbow evaluation (PREE), quick disabilities of the arm, shoulder and hand (qDASH), and EuroQol (five dimensions) 3-level version (EQ5D3L) questionnaires were documented at each visit including 6 months after the first injection. These outcomes were compared between patients receiving 1 vs. 2 or 3 PRP injections. Sixty-two patients received one (n = 36) or more (n = 26) PRP injections. The mean baseline to 6-month follow-up scores of the PREE and qDASH questionnaires improved significantly from 54.0 to 23.0 and 50.3 to 20.7, respectively. The mean baseline EQ5D3L-visual analogue scale score improved from 62.5 to 82.9 by 6 months post-injection. These outcomes did not significantly differ between the patients who received varying numbers of injections. Patients with chronic lateral epicondylitis reported significant pain relief and gain in function as well as quality of life 6 months after localized PRP treatment. A single PRP injection may be sufficient.

  3. Comparison of Single Intra-Articular Injection of Novel Hyaluronan (HYA-JOINT Plus) with Synvisc-One for Knee Osteoarthritis: A Randomized, Controlled, Double-Blind Trial of Efficacy and Safety.

    PubMed

    Sun, Shu-Fen; Hsu, Chien-Wei; Lin, Huey-Shyan; Liou, I-Hsiu; Chen, Yin-Han; Hung, Chia-Ling

    2017-03-15

    Viscosupplementation has been widely used for the treatment of knee osteoarthritis. Because we found no well-controlled trial comparing single-injection regimens of hyaluronan for knee osteoarthritis, we compared the efficacy and safety of a single intra-articular injection of a novel cross-linked hyaluronan (HYA-JOINT Plus) with a single injection of Synvisc-One in patients with knee osteoarthritis. In a prospective, randomized, controlled, double-blind trial with a 6-month follow-up, 132 patients with knee osteoarthritis (Kellgren-Lawrence grade 2 or 3) were randomized to receive 1 intra-articular injection of 3 mL of HYA-JOINT Plus (20 mg/mL) (n = 66) or 6 mL of Synvisc-One (8 mg/mL) (n = 66). The primary outcome was the change from baseline in the visual analog scale (VAS) (0 to 100 mm) pain score at 6 months. Secondary outcome measures included the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC, Likert scale), Lequesne index, timed "Up & Go" (TUG) test, single-limb stance (SLS) test, use of rescue analgesics, and patient satisfaction. A total of 121 patients were available for the intention-to-treat analysis at 6 months. Both groups had a significant improvement in the VAS, WOMAC, and Lequesne index scores at each follow-up visit (p < 0.001). Patients who received HYA-JOINT Plus experienced a significantly greater improvement in the VAS pain score at 1, 3, and 6 months compared with those treated with Synvisc-One (adjusted mean difference: -12.0, -8.5, and -6.6; p = 0.001, 0.033, and 0.045, respectively). There were no significant between-group differences in any of the secondary outcomes except the WOMAC stiffness scores at 6 months, which favored HYA-JOINT Plus treatment (p = 0.043). The TUG time did not change significantly in either group during the study (p > 0.05), but the SLS time improved significantly in both the HYA-JOINT Plus and the Synvisc-One group (p = 0.004 and p = 0.022, respectively). No significant between-group differences were observed with respect to patient satisfaction or consumption of analgesics. No serious adverse events occurred following the injections. A single injection of either HYA-JOINT Plus or Synvisc-One is safe and effective for 6 months in patients with knee osteoarthritis. HYA-JOINT Plus is superior to Synvisc-One in terms of reducing the VAS pain score at 1, 3, and 6 months and the WOMAC stiffness score at 6 months, with similar safety. Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.

  4. Inhibitive effects of anti-oxidative vitamins on mannitol-induced apoptosis of vascular endothelial cells.

    PubMed

    Pan, Kai-yu; Shen, Mei-ping; Ye, Zhi-hong; Dai, Xiao-na; Shang, Shi-qiang

    2006-10-01

    Study blood vessel injury and gene expression indicating vascular endothelial cell apoptosis induced by mannitol with and without administration of anti-oxidative vitamins. Healthy rabbits were randomly divided into four groups. Mannitol was injected into the vein of the rabbit ear in each animal. Pre-treatment prior to mannitol injection was performed with normal saline (group B), vitamin C (group C) and vitamin E (group D). Blood vessel injury was assessed under electron and light microscopy. In a second experiment, cell culture specimen of human umbilical vein endothelial cells were treated with mannitol. Pre-treatment was done with normal saline (sample B), vitamin C (sample C) and vitamin E (sample D). Total RNA was extracted with the original single step procedure, followed by hybridisation and analysis of gene expression. In the animal experiment, serious blood vessel injury was seen in group A and group B. Group D showed light injury only, and normal tissue without pathological changes was seen in group C. Of all 330 apoptosis-related genes analysed in human cell culture specimen, no significant difference was seen after pre-treatment with normal saline, compared with the gene chip without pre-treatment. On the gene chip pre-treated with vitamin C, 45 apoptosis genes were down-regulated and 34 anti-apoptosis genes were up-regulated. Pre-treatment with vitamin E resulted in the down-regulation of 3 apoptosis genes. Vitamin C can protect vascular endothelial cells from mannitol-induced injury.

  5. Engulfing tumors with synthetic extracellular matrices for cancer immunotherapy.

    PubMed

    Hori, Yuki; Stern, Patrick J; Hynes, Richard O; Irvine, Darrell J

    2009-12-01

    Local immunotherapies are under investigation for the treatment of unresectable tumors and sites of solid tumor resection to prevent local recurrence. Successful local therapy could also theoretically elicit systemic immune responses against cancer. Here we explored the delivery of therapeutic dendritic cells (DCs), cytokines, or other immunostimulatory factors to tumors via the use of 'self-gelling' hydrogels based on the polysaccharide alginate, injected peritumorally around established melanoma lesions. Peritumoral injection of alginate matrices loaded with DCs and/or an interleukin-15 superagonist (IL-15SA) around 14-day established ova-expressing B16F0 murine melanoma tumors promoted immune cell accumulation in the peritumoral matrix, and matrix infiltration correlated with tumor infiltration by leukocytes. Single injections of IL-15SA-carrying gels concentrated the cytokine in the tumor site approximately 40-fold compared to systemic injection and enabled a majority of treated animals to suppress tumor growth for a week or more. Further, we found that single injections of alginate matrices loaded with IL-15SA and the Toll-like receptor ligand CpG or two injections of gels carrying IL-15SA alone could elicit comparable anti-tumor activity without the need for exogenous DCs. Thus, injectable alginate gels offer an attractive platform for local tumor immunotherapy, and facilitate combinatorial treatments designed to promote immune responses locally at a tumor site while limiting systemic exposure to potent immunomodulatory factors.

  6. Control of high-Z PFC erosion by local gas injection in DIII-D

    NASA Astrophysics Data System (ADS)

    Rudakov, D. L.; Stangeby, P. C.; Wong, C. P. C.; McLean, A. G.; Wampler, W. R.; Watkins, J. G.; Boedo, J. A.; Briesemeister, A.; Buchenauer, D. A.; Chrobak, C. P.; Elder, J. D.; Fenstermacher, M. E.; Guo, H. Y.; Lasnier, C. J.; Leonard, A. W.; Maingi, R.; Moyer, R. A.

    2015-08-01

    Reduced erosion of a high-Z PFC divertor surface was observed in DIII-D with local injection of methane and deuterium gases. Molybdenum-coated silicon samples were exposed in the lower divertor of DIII-D using DiMES under plasma conditions previously shown to cause significant net erosion of Mo. Three exposures with 13CH4 and one exposure with D2 gas injection about 12 cm upstream of the samples located within 1-2 cm of the attached strike point were performed. Reduction of Mo erosion was evidenced in-situ by the suppression of MoI line radiation at 386.4 nm once the gas injection started. Post-mortem ion beam analysis demonstrated that the net erosion of molybdenum near the center of the samples exposed with 13CH4 injection was below the measurement resolution of 0.5 nm, corresponding to a rate of ⩽0.04 nm/s. Compared to the previously measured erosion rates, this constitutes a reduction by a factor of >10.

  7. Silver nanoparticles as a key feature of a plasma polymer composite layer in mitigation of charge injection into polyethylene under dc stress

    NASA Astrophysics Data System (ADS)

    Milliere, L.; Maskasheva, K.; Laurent, C.; Despax, B.; Boudou, L.; Teyssedre, G.

    2016-01-01

    The aim of this work is to limit charge injection from a semi-conducting electrode into low density polyethylene (LDPE) under dc field by tailoring the polymer surface using a silver nanoparticles-containing layer. The layer is composed of a plane of silver nanoparticles embedded in a semi-insulating organosilicon matrix deposited on the polyethylene surface by a plasma process. Size, density and surface coverage of the nanoparticles are controlled through the plasma process. Space charge distribution in 300 μm thick LDPE samples is measured by the pulsed-electroacoustic technique following a short term (step-wise voltage increase up to 50 kV mm-1, 20 min in duration each, followed by a polarity inversion) and a longer term (up to 12 h under 40 kV mm-1) protocols for voltage application. A comparative study of space charge distribution between a reference polyethylene sample and the tailored samples is presented. It is shown that the barrier effect depends on the size distribution and the surface area covered by the nanoparticles: 15 nm (average size) silver nanoparticles with a high surface density but still not percolating form an efficient barrier layer that suppress charge injection. It is worthy to note that charge injection is detected for samples tailored with (i) percolating nanoparticles embedded in organosilicon layer; (ii) with organosilicon layer only, without nanoparticles and (iii) with smaller size silver particles (<10 nm) embedded in organosilicon layer. The amount of injected charges in the tailored samples increases gradually in the samples ranking given above. The mechanism of charge injection mitigation is discussed on the basis of complementary experiments carried out on the nanocomposite layer such as surface potential measurements. The ability of silver clusters to stabilize electrical charges close to the electrode thereby counterbalancing the applied field appears to be a key factor in explaining the charge injection mitigation effect.

  8. Mujer Mas Segura (Safer Women): a combination prevention intervention to reduce sexual and injection risks among female sex workers who inject drugs.

    PubMed

    Vera, Alicia; Abramovitz, Daniela; Lozada, Remedios; Martinez, Gustavo; Rangel, M Gudelia; Staines, Hugo; Patterson, Thomas L; Strathdee, Steffanie A

    2012-08-14

    Female sex workers who inject drugs (FSW-IDUs) are at risk of acquiring HIV, sexually transmitted infections (STI) and blood-borne infections through unprotected sex and sharing injection equipment. We conducted a 2×2 factorial randomized controlled trial to evaluate combination interventions to simultaneously reduce sexual and injection risks among FSW-IDUs in Tijuana and Ciudad Juarez, Mexico. FSW-IDUs ≥18 years reporting sharing injection equipment and unprotected sex with clients within the last month were randomized to one of four conditions based on an a priori randomization schedule, blinding interviewer/counselors to assignment. Due to the extreme vulnerability of this population, we did not include a control group that would deny some women access to preventive information. All women received similar information regardless of group allocation; the difference was in the way the information was delivered and the extent to which women had an interactive role. Each condition was a single 60-minute session, including either an interactive or didactic version of an injection risk intervention and sexual risk intervention. Women underwent interviewer-administered surveys and testing for HIV, syphilis, gonorrhea, Chlamydia, and Trichomonas at baseline and quarterly for 12 months. Combined HIV/STI incidence will be the primary outcome. Secondary outcomes are proportionate reductions in sharing of injection equipment and unprotected sex with clients. Of 1,132 women, 548 (48.4%) were excluded (88.9% were ineligible; 11.1% refused to participate or did not return); 584 eligible women enrolled (284 in Tijuana; 300 in Ciudad Juarez). All 584 participants completed the baseline interview, provided biological samples and were randomized to one of the four groups. During follow-up, 17 participants (2.9%) were lost to follow-up, of whom 10 (58.8%) had died, leaving 567 participants for analysis. This study appears to be the first intervention to attempt to simultaneously reduce injection and sexual risk behaviors among FSW-IDUs. The factorial design will permit analysis to determine whether the combination of the two interactive interventions and/or its respective components are effective in reducing injection and/or sexual risks, which will have direct, tangible policy implications for Mexico and potentially other resource-poor countries. NCT00840658.

  9. Mujer Mas Segura (Safer Women): a combination prevention intervention to reduce sexual and injection risks among female sex workers who inject drugs

    PubMed Central

    2012-01-01

    Background Female sex workers who inject drugs (FSW-IDUs) are at risk of acquiring HIV, sexually transmitted infections (STI) and blood-borne infections through unprotected sex and sharing injection equipment. We conducted a 2×2 factorial randomized controlled trial to evaluate combination interventions to simultaneously reduce sexual and injection risks among FSW-IDUs in Tijuana and Ciudad Juarez, Mexico. Methods/design FSW-IDUs ≥18 years reporting sharing injection equipment and unprotected sex with clients within the last month were randomized to one of four conditions based on an a priori randomization schedule, blinding interviewer/counselors to assignment. Due to the extreme vulnerability of this population, we did not include a control group that would deny some women access to preventive information. All women received similar information regardless of group allocation; the difference was in the way the information was delivered and the extent to which women had an interactive role. Each condition was a single 60-minute session, including either an interactive or didactic version of an injection risk intervention and sexual risk intervention. Women underwent interviewer-administered surveys and testing for HIV, syphilis, gonorrhea, Chlamydia, and Trichomonas at baseline and quarterly for 12 months. Combined HIV/STI incidence will be the primary outcome. Secondary outcomes are proportionate reductions in sharing of injection equipment and unprotected sex with clients. Discussion Of 1,132 women, 548 (48.4%) were excluded (88.9% were ineligible; 11.1% refused to participate or did not return); 584 eligible women enrolled (284 in Tijuana; 300 in Ciudad Juarez). All 584 participants completed the baseline interview, provided biological samples and were randomized to one of the four groups. During follow-up, 17 participants (2.9%) were lost to follow-up, of whom 10 (58.8%) had died, leaving 567 participants for analysis. This study appears to be the first intervention to attempt to simultaneously reduce injection and sexual risk behaviors among FSW-IDUs. The factorial design will permit analysis to determine whether the combination of the two interactive interventions and/or its respective components are effective in reducing injection and/or sexual risks, which will have direct, tangible policy implications for Mexico and potentially other resource-poor countries. Trial registration NCT00840658 PMID:22891807

  10. Measurements of CO, CO2, OH, and H2O in room-temperature and combustion gases by use of a broadly current-tuned multisection InGaAsP diode laser.

    PubMed

    Upschulte, B L; Sonnenfroh, D M; Allen, M G

    1999-03-20

    A new laser technology that achieves nearly 100-nm quasi-continuous tuning with only injection-current control in a four-section grating-coupler sampled-reflector laser was used to detect CO and CO(2) simultaneously in room-temperature gas mixtures. The same grating-coupler sampled-reflector laser was used to perform in situ measurements of CO, H(2)O, and OH in the exhaust gases of a CH(4)-air flame. This laser is being evaluated for inclusion in a multispecies combustion-emissions exhaust-analysis sensor, and its operational characteristics as they have an impact on gas sensing are described. Preliminary results suggest that this single laser can be used to replace multilaser sensor configurations for some combustion-emissions monitoring applications.

  11. Anesthetic efficacy of a repeated intraosseous injection following a primary intraosseous injection.

    PubMed

    Jensen, Joanne; Nusstein, John; Drum, Melissa; Reader, Al; Beck, Mike

    2008-02-01

    The purpose of this prospective, randomized, single-blinded study was to determine the anesthetic efficacy of a repeated intraosseous injection given 30 minutes after a primary intraosseous injection. Using a crossover design, 55 subjects randomly received a primary X-tip intraosseous injection (Dentsply Inc, York, PA) of 1.4 mL of 2% lidocaine with epinephrine (using the Wand; Milestone Scientific, Deerfield, IL) and a repeated intraosseous or mock injection at 30 minutes in two appointments. The first molar and adjacent teeth were pulp tested every 2 minutes for a total of 120 minutes. Success was defined as obtaining two consecutive 80 readings with the electric pulp tester. Success of the initial intraosseous injection was 100% for the first molar. The repeated intraosseous injection mimicked the initial intraosseous injection in terms of pulpal anesthesia and statistically provided another 15 minutes of pulpal anesthesia. In conclusion, using the methodology presented, repeating the intraosseous injection 30 minutes after an initial intraosseous injection will provide an additional 15 minutes of pulpal anesthesia.

  12. Analysis of Thermal and Chemical Effets on Negative Valve Overlap Period Energy Recovery for Low-Temperature Gasoline Combustion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ekoto, Dr Isaac; Peterson, Dr. Brian; Szybist, James P

    2015-01-01

    A central challenge for efficient auto-ignition controlled low-temperature gasoline combustion (LTGC) engines has been achieving the combustion phasing needed to reach stable performance over a wide operating regime. The negative valve overlap (NVO) strategy has been explored as a way to improve combustion stability through a combination of charge heating and altered reactivity via a recompression stroke with a pilot fuel injection. The study objective was to analyze the thermal and chemical effects on NVO-period energy recovery. The analysis leveraged experimental gas sampling results obtained from a single-cylinder LTGC engine along with cylinder pressure measurements and custom data reduction methodsmore » used to estimate period thermodynamic properties. The engine was fueled by either iso-octane or ethanol, and operated under sweeps of NVO-period oxygen concentration, injection timing, and fueling rate. Gas sampling at the end of the NVO period was performed via a custom dump-valve apparatus, with detailed sample speciation by in-house gas chromatography. The balance of NVO-period input and output energy flows was calculated in terms of fuel energy, work, heat loss, and change in sensible energy. Experiment results were complemented by detailed chemistry single-zone reactor simulations performed at relevant mixing and thermodynamic conditions, with results used to evaluate ignition behavior and expected energy recovery yields. For the intermediate bulk-gas temperatures present during the NVO period (900-1100 K), weak negative temperature coefficient behavior with iso-octane fueling significantly lengthened ignition delays relative to similar ethanol fueled conditions. Faster ethanol ignition chemistry led to lower recovered fuel intermediate yields relative to similar iso-octane fueled conditions due to more complete fuel oxidation. From the energy analysis it was found that increased NVO-period global equivalence ratio, either from lower NVOperiod oxygen concentrations or higher fueling rates, in general led to a greater fraction of net recovered fuel energy and work as heat losses were minimized. These observations were supported by complementary single-zone reactor model results, which further indicated that kinetic time-scales favor chemical energy-consuming exothermic oxidation over slower endothermic reformation. Nonetheless, fuel energy recovery close to the thermodynamic equilibrium solution was achieved for baseline conditions that featured 4% NVO-period oxygen concentration.« less

  13. Determination of the forces imposed by micro and nanopipettes during DOPC: DOPS liposome manipulation.

    PubMed

    Allen, Kathleen B; Layton, Bradley E

    2009-11-01

    Using micropipette-based probing methods and an image processing algorithm for measuring deformation, the bending energies of aspirated DOPC:DOPS liposomes were estimated both before and during manipulation with an injection pipette. We found that unlike cells, which are penetrable with pipettes as large as 2mum in diameter and at speeds as slow as 4mum/s, liposomes, without a cytoskeleton to resist deformation, are impenetrable with pipettes as small as 25nm in diameter and at speeds as great as 4000mum/s. Using energy calculations and the previously published mechanical properties of DOPC:DOPS liposomes, the forces that injection pipettes of various sizes can exert onto liposomes during probing were estimated. Forces ranged from approximately 1pN to 6pN, and the forces exerted onto these liposomes increased as pipette size diminished. The quantification of the amount of force exerted on liposomes or cells during manipulation can assist in minimizing the damage during single-liposome, single-cell, or single-organelle injections and surgeries.

  14. Experiments in dilution jet mixing

    NASA Technical Reports Server (NTRS)

    Holdeman, J. D.; Srinivasan, R.; Berenfeld, A.

    1983-01-01

    Experimental results are given on the mixing of a single row of jets with an isothermal mainstream in a straight duct, to include flow and geometric variations typical of combustion chambers in gas turbine engines. The principal conclusions reached from these experiments were: at constant momentum ratio, variations in density ratio have only a second-order effect on the profiles; a first-order approximation to the mixing of jets with a variable temperature mainstream can be obtained by superimposing the jets-in-an isothermal-crossflow and mainstream profiles; flow area convergence, especially injection-wall convergence, significantly improves the mixing; for opposed rows of jets, with the orifice centerlines in-line, the optimum ratio of orifice spacing to duct height is one half of the optimum value for single side injection at the same momentum ratio; and for opposed rows of jets, with the orifice centerlines staggered, the optimum ratio of orifice spacing to duct height is twice the optimum value for single side injection at the same momentum ratio.

  15. Exciton dynamics of C60-based single-photon emitters explored by Hanbury Brown-Twiss scanning tunnelling microscopy.

    PubMed

    Merino, P; Große, C; Rosławska, A; Kuhnke, K; Kern, K

    2015-09-29

    Exciton creation and annihilation by charges are crucial processes for technologies relying on charge-exciton-photon conversion. Improvement of organic light sources or dye-sensitized solar cells requires methods to address exciton dynamics at the molecular scale. Near-field techniques have been instrumental for this purpose; however, characterizing exciton recombination with molecular resolution remained a challenge. Here, we study exciton dynamics by using scanning tunnelling microscopy to inject current with sub-molecular precision and Hanbury Brown-Twiss interferometry to measure photon correlations in the far-field electroluminescence. Controlled injection allows us to generate excitons in solid C60 and let them interact with charges during their lifetime. We demonstrate electrically driven single-photon emission from localized structural defects and determine exciton lifetimes in the picosecond range. Monitoring lifetime shortening and luminescence saturation for increasing carrier injection rates provides access to charge-exciton annihilation dynamics. Our approach introduces a unique way to study single quasi-particle dynamics on the ultimate molecular scale.

  16. Simultaneous determination of dechloranes, polybrominated diphenyl ethers and novel brominated flame retardants in food and serum.

    PubMed

    Sales, Carlos; Poma, Giulia; Malarvannan, Govindan; Portolés, Tania; Beltrán, Joaquin; Covaci, Adrian

    2017-07-01

    A sensitive method for the simultaneous quantification of dechloranes, polybrominated diphenyl ethers (PBDEs) and novel brominated flame retardants (NBFRs) has been developed for gas chromatography (GC) coupled to tandem mass spectrometry operating in electron capture negative ionization (ECNI) mode. The major advance has been achieved by combining selected ion monitoring (SIM) and multiple reaction monitoring (MRM) modes in well-defined time windows, to determine dechloranes, PBDEs and NBFRs at picogram per gram level in one single analysis in complex matrix biological samples. From the chromatographic point of view, efforts were devoted to study several injection modes using multimode inlet (MMI) in order to obtain low instrumental detection limits, necessary for trace compounds such as Dechlorane Plus (DP) isomers. Method performance was also evaluated: calibration curves were linear from 20 fg μL -1 to 100 pg μL -1 for the studied compounds, with method detection limits at levels of 50 fg g -1 for DPs. Repeatability and reproducibility, expressed as relative standard deviation, were better than 5% even in solvent vent mode for the injection of standards. The application to a wide range of complex samples (including food, human and animal serum samples) indicated a sensitive and reliable way to quantify at the picogram per gram level 4 halogenated norbornenes (HNs), Dechlorane Plus (anti-DP and syn-DP) and 2 of their homologues (Dechlorane-602 and Dechlorane-603), 11 PBDE congeners (no. 28, 47, 49, 66, 85, 99, 100, 153, 154, 183 and 209) and 5 novel BFRs, i.e. decabromodiphenyl ethane (DBDPE), 1,2-bis(2,4,6-tribromophenoxy)ethane (BTBPE), hexabromobenzene (HBB), 2,3,4,5-tetrabromo-ethylhexyl-benzoate (TBB) and tetrabromophthalate (TBPH). Graphical Abstract GC-ECNI-MS/MS chromatograms showing the most sensitive transition for DPs when injecting 2 μL of a 16 fg/μL standard solution of s-DP and a-DP at three different source temperatures.

  17. MEASURING TRANSIT SIGNAL RECOVERY IN THE KEPLER PIPELINE. I. INDIVIDUAL EVENTS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Christiansen, Jessie L.; Clarke, Bruce D.; Burke, Christopher J.

    The Kepler mission was designed to measure the frequency of Earth-size planets in the habitable zone of Sun-like stars. A crucial component for recovering the underlying planet population from a sample of detected planets is understanding the completeness of that sample-the fraction of the planets that could have been discovered in a given data set that actually were detected. Here, we outline the information required to determine the sample completeness, and describe an experiment to address a specific aspect of that question, i.e., the issue of transit signal recovery. We investigate the extent to which the Kepler pipeline preserves individualmore » transit signals by injecting simulated transits into the pixel-level data, processing the modified pixels through the pipeline, and comparing the measured transit signal-to-noise ratio (S/N) to that expected without perturbation by the pipeline. We inject simulated transit signals across the full focal plane for a set of observations for a duration of 89 days. On average, we find that the S/N of the injected signal is recovered at MS = 0.9973({+-} 0.0012) Multiplication-Sign BS - 0.0151({+-} 0.0049), where MS is the measured S/N and BS is the baseline, or expected, S/N. The 1{sigma} width of the distribution around this correlation is {+-}2.64%. This indicates an extremely high fidelity in reproducing the expected detection statistics for single transit events, and provides teams performing their own periodic transit searches the confidence that there is no systematic reduction in transit signal strength introduced by the pipeline. We discuss the pipeline processes that cause the measured S/N to deviate significantly from the baseline S/N for a small fraction of targets; these are primarily the handling of data adjacent to spacecraft re-pointings and the removal of harmonics prior to the measurement of the S/N. Finally, we outline the further work required to characterize the completeness of the Kepler pipeline.« less

  18. Systematic assessment of microneedle injection into the mouse cornea

    PubMed Central

    2012-01-01

    Background Corneal intrastromal injection is an important mode of gene-vector application to subepithelial layers. In a mouse model, this procedure is substantially complicated by the reduced corneal dimensions. Furthermore, it may be difficult to estimate the corneal area reached by the volume of a single injection. This study aimed to investigate intrastromal injections into the mouse cornea using different microneedles and to quantify the effect of injecting varying volumes. A reproducible injection technique is described. Methods Forty eyes of 20 129 Sv/J mice were tested. India ink was intrastromally injected using 30° beveled 33 G needles, tri-surface 25° beveled 35 G needles, or hand-pulled and 25° beveled glass needles. Each eye received a single injection of a volume of 1 or 2 μL. Corneoscleral buttons were fixed and flat mounted for computer-assisted quantification of the affected corneal area. Histological assessment was performed to investigate the intrastromal location of the injected dye. Results A mean corneal area of 5.0 ±1.4 mm2 (mean ± SD) and 7.7 ±1.4 mm2 was covered by intrastromal injections of 1 and 2 μL, respectively. The mean percentage of total corneal area reached ranged from 39% to 53% for 1 μL injections, and from 65% to 81% for 2 μL injections. Injections using the 33 G needles tended to provide the highest distribution area. Perforation rates were 8% for 30° beveled 33 G needles and 44% for tri-surface beveled 35 G needles. No perforation was observed with glass needle; however, intrastromal breakage of needle tips was noted in 25% of these cases. Conclusions Intracorneal injection using a 30° beveled 33 G needle was safe and effective. The use of tri-surface beveled 35 G needles substantially increased the number of corneal perforations. Glass needles may break inside the corneal stroma. Injections of 1 μL and 2 μL resulted in an overall mean of 49% and 73% respectively of total corneal area involved. PMID:22716296

  19. Systematic assessment of microneedle injection into the mouse cornea.

    PubMed

    Matthaei, Mario; Meng, Huan; Bhutto, Imran; Xu, Qingguo; Boelke, Edwin; Hanes, Justin; Jun, Albert S

    2012-06-20

    Corneal intrastromal injection is an important mode of gene-vector application to subepithelial layers. In a mouse model, this procedure is substantially complicated by the reduced corneal dimensions. Furthermore, it may be difficult to estimate the corneal area reached by the volume of a single injection. This study aimed to investigate intrastromal injections into the mouse cornea using different microneedles and to quantify the effect of injecting varying volumes. A reproducible injection technique is described. Forty eyes of 20 129 Sv/J mice were tested. India ink was intrastromally injected using 30° beveled 33 G needles, tri-surface 25° beveled 35 G needles, or hand-pulled and 25° beveled glass needles. Each eye received a single injection of a volume of 1 or 2 μL. Corneoscleral buttons were fixed and flat mounted for computer-assisted quantification of the affected corneal area. Histological assessment was performed to investigate the intrastromal location of the injected dye. A mean corneal area of 5.0 ± 1.4 mm(2) (mean ± SD) and 7.7 ± 1.4 mm(2) was covered by intrastromal injections of 1 and 2 μL, respectively. The mean percentage of total corneal area reached ranged from 39% to 53% for 1 μL injections, and from 65% to 81% for 2 μL injections. Injections using the 33 G needles tended to provide the highest distribution area. Perforation rates were 8% for 30° beveled 33 G needles and 44% for tri-surface beveled 35 G needles. No perforation was observed with glass needle; however, intrastromal breakage of needle tips was noted in 25% of these cases. Intracorneal injection using a 30° beveled 33 G needle was safe and effective. The use of tri-surface beveled 35 G needles substantially increased the number of corneal perforations. Glass needles may break inside the corneal stroma. Injections of 1 μL and 2 μL resulted in an overall mean of 49% and 73% respectively of total corneal area involved.

  20. Pharmacokinetics of buprenorphine after single-dose subcutaneous administration in red-eared sliders (Trachemys scripta elegans).

    PubMed

    Kummrow, Maya S; Tseng, Florina; Hesse, Leah; Court, Michael

    2008-12-01

    Buprenorphine, a mu opioid receptor agonist, is expected to be a suitable analgesic drug for use in reptiles. However, to date, dosage recommendations have been based on anecdotal observations. The aim of this study was to provide baseline pharmacokinetic data in red-eared sliders (Trachemys scripta elegans) targeting a plasma level of 1 ng/ml reported effective for analgesia in humans. Serial blood samples were taken after subcutaneous injection of buprenorphine, and plasma buprenorphine levels were measured by radioimmunoassay. Pharmacokinetic parameters of a lower dose (0.02 mg/kg) injected into the forelimb were compared with a higher dose (0.05 mg/kg) given in the same forelimb as well as a lower dose (0.02 mg/kg) given in the hind limb of the same animals with 2 wk between studies. After administration of 0.05 mg/kg in the front limb, 85% of animals maintained the minimum effective plasma level for 24 hr, while only 43% of animals maintained this level after 0.02 mg/kg. After hind limb injection at 0.02 mg/kg, maximum plasma concentrations and areas under the buprenorphine concentration-time curve were less than 20% and 70%, respectively, of values after forelimb injection, consistent with substantial first pass extraction by the liver. Furthermore, a secondary rise in the buprenorphine level was found after having only a hind limb injection, probably from enterohepatic recirculation of glucuronidated drug. In conclusion, buprenorphine dosages of at least 0.075 mg/kg s.i.d. should be appropriate for evaluation of analgesia efficacy, and front limb administration may be preferable to hind limb administration for optimal drug exposure.

  1. Kepler Planet Detection Metrics: Per-Target Flux-Level Transit Injection Tests of TPS for Data Release 25

    NASA Technical Reports Server (NTRS)

    Burke, Christopher J.; Catanzarite, Joseph

    2017-01-01

    Quantifying the ability of a transiting planet survey to recover transit signals has commonly been accomplished through Monte-Carlo injection of transit signals into the observed data and subsequent running of the signal search algorithm (Gilliland et al., 2000; Weldrake et al., 2005; Burke et al., 2006). In order to characterize the performance of the Kepler pipeline (Twicken et al., 2016; Jenkins et al., 2017) on a sample of over 200,000 stars, two complementary injection and recovery tests are utilized:1. Injection of a single transit signal per target into the image or pixel-level data, hereafter referred to as pixel-level transit injection (PLTI), with subsequent processing through the Photometric Analysis (PA), Presearch Data Conditioning (PDC), Transiting Planet Search (TPS), and Data Validation (DV) modules of the Kepler pipeline. The PLTI quantification of the Kepler pipeline's completeness has been described previously by Christiansen et al. (2015, 2016); the completeness of the final SOC 9.3 Kepler pipeline acting on the Data Release 25 (DR25) light curves is described by Christiansen (2017).2. Injection of multiple transit signals per target into the normalized flux time series data with a subsequent transit search using a stream-lined version of the Transiting Planet Search (TPS) module. This test, hereafter referred to as flux-level transit injection (FLTI), is the subject of this document. By running a heavily modified version of TPS, FLTI is able to perform many injections on selected targets and determine in some detail which injected signals are recoverable. Significant numerical efficiency gains are enabled by precomputing the data conditioning steps at the onset of TPS and limiting the search parameter space (i.e., orbital period, transit duration, and ephemeris zero-point) to a small region around each injected transit signal.The PLTI test has the advantage that it follows transit signals through all processing steps of the Kepler pipeline, and the recovered signals can be further classified as planet candidates or false positives in the exact same manner as detections from the nominal (i.e., observed) pipeline run (Twicken et al., 2016, Thompson et al., in preparation). To date, the PLTI test has been the standard means of measuring pipeline completeness averaged over large samples of targets (Christiansen et al., 2015, 2016; Christiansen, 2017). However, since the PLTI test uses only one injection per target, it does not elucidate individual-target variations in pipeline completeness due to differences in stellar properties or astrophysical variability. Thus, we developed the FLTI test to provide a numerically efficient way to fully map individual targets and explore the performance of the pipeline in greater detail. The FLTI tests thereby allow a thorough validation of the pipeline completeness models (such as window function (Burke and Catanzarite, 2017a), detection efficiency (Burke Catanzarite, 2017b), etc.) across the spectrum of Kepler targets (i.e., various astrophysical phenomena and differences in instrumental noise). Tests during development of the FLTI capability revealed that there are significant target-to-target variations in the detection efficiency.

  2. Chromium Isotopic Monitoring of HRC-Stimulated Bio-containment at the 100H Test Site, Hanford, Washington

    NASA Astrophysics Data System (ADS)

    Christensen, J. N.; Brown, S. T.; Brodie, E. L.; Chakraborty, R.; Conrad, M. E.; Long, P. E.; Faybishenko, B.; Hazen, T. C.

    2007-12-01

    Hexavalent Cr (Cr(VI)) groundwater contamination is a common problem in the U.S. associated with industrial activity (e.g. electroplating, tanning, paints, anti-corrosion). In the particular case of the Hanford Site, Washington, chromate was used primarily to inhibit corrosion in nuclear reactor cooling systems. During the active operation of the Hanford Site, disposal of waste water bearing chromate, and accidental releases to the vadose zone resulted in significant groundwater contamination with local concentrations near the Columbia river reaching over 1000 ppb Cr(VI). In an effort to test an effective bio-containment strategy for groundwater Cr(VI), a site was selected between the 100D and 100H reactor areas with modest concentrations (~100 ppb Cr(VI) over the past two decades). A slow-release 13C labeled polylactate amendment (HRCTM, Regenesis, Ltd.) was injected into groundwater within a sandy formation to stimulate bacterial activity in order to produce conditions that promote the reduction of dissolved Cr(VI) to insoluble Cr(III) complexes [1]. Since the injection of HRCTM in August 2004, groundwater Cr(VI) concentration has been locally below 1 ppb, and reducing conditions have been maintained to at least the present time. The isotopic composition of Cr can be fractionated during reduction from Cr(VI) to Cr(III) and so has the potential to be used as a monitor of hexavalent Cr reduction [2, 3]. This would provide a direct signature of Cr(VI) reduction, discernable from simple attenuation by dilution. In order to explore the use of Cr isotopic measurements for evaluating processes of Cr(VI) reduction, we have analyzed a series of samples in space and time for Cr isotopic composition (δ53Cr, permil deviation of sample 53Cr/52Cr from that of SRM970). Groundwater samples came from the HRC injection well, from multiple depths of three down-gradient wells, and from an up-gradient well. Samples from down-gradient wells have Cr that is isotopically fractionated relative to samples from the up-gradient well. Taken together, samples from a single sampling campaign yield an apparent fractionation of 2.2 ‰. Cr isotopic measurements of the latest samples (June, 2007) confirm continued reduction of Cr(VI) nearly three years after the introduction of HRCTM, suggesting the long-term effectiveness of this bio-stimulated containment strategy. [1] http://esd.lbl.gov/ERT/hanford100h/ [2] Ellis, AS, Johnson, TM and Bohlen, TD (2002) Science. 295:2060-2062. [3] Johnson, TM and Bohlen, TD (2004) Reviews in Mineralogy and Geochemistry, Vol. 55, p.289-317.

  3. Clinical value of transforaminal epidural steroid injection in lumbar radiculopathy.

    PubMed

    Leung, S M; Chau, W W; Law, S W; Fung, K Y

    2015-10-01

    To identify the diagnostic, therapeutic, and prognostic values of transforaminal epidural steroid injection as interventional rehabilitation for lumbar radiculopathy. Regional hospital, Hong Kong. A total of 232 Chinese patients with lumbar radiculopathy attributed to disc herniation or spinal stenosis received transforaminal epidural steroid injection between 1 January 2007 and 31 December 2011. Transforaminal epidural steroid injection. Patients' immediate response, response duration, proportion of patients requiring surgery, and risk factors affecting the responses to transforaminal epidural steroid injection for lumbar radiculopathy. Of the 232 patients, 218 (94.0%) had a single level of radiculopathy and 14 (6.0%) had multiple levels. L5 was the most commonly affected level. The immediate response rate to transforaminal epidural steroid injection was 80.2% in 186 patients with clinically diagnosed lumbar radiculopathy and magnetic resonance imaging of the lumbar spine suggesting nerve root compression. Of patients with single-level radiculopathy and multiple-level radiculopathy, 175 (80.3%) and 11 (78.6%) expressed an immediate response to transforaminal epidural steroid injection, respectively. The analgesic effect lasted for 1 to <3 weeks in 35 (15.1%) patients, for 3 to 12 weeks in 37 (15.9%) patients, and for more than 12 weeks in 92 (39.7%) patients. Of the 232 patients, 106 (45.7%) were offered surgery, with 65 (61.3%) undergoing operation, and with 42 (64.6%) requiring spinal fusion in addition to decompression surgery. Symptom chronicity was associated with poor immediate response to transforaminal epidural steroid injection, but not with duration of pain reduction. Poor response to transforaminal epidural steroid injection was not associated with a preceding industrial injury. The immediate response to transforaminal epidural steroid injection was approximately 80%. Transforaminal epidural steroid injection is a useful diagnostic, prognostic, and short-term therapeutic tool for lumbar radiculopathy. Although transforaminal epidural steroid injection cannot alter the need for surgery in the long term, it is a reasonably safe procedure to provide short-term pain relief and as a preoperative assessment tool.

  4. Impact de l'utilisation des strategies d'injection multiple et de biodiesel sur un moteur diesel a rampe commune d'injection

    NASA Astrophysics Data System (ADS)

    Plamondon, Etienne

    Using biodiesel/diesel fuel blends and multiple injection strategies in diesel engines have shown promising results in improving the trade-off relationship between nitrous oxides and particulate matters, but their effects are still not completely understood. In this context, this thesis focuses on the characterization of the multiple injection strategies and biodiesel impacts on pollutant emissions, performances and injection system behavior. To reach this goal, an experimental campaign on a diesel engine was performed and a model simulating the injection process was developed. The engine tests at low load with pilot injection allowed the reduction of NOx emissions up to 27% and those of PM up to 22.3% compared to single injection, provided that a precise tuning of the injection parameters was previously realized. This simultaneous reduction is explained by the reduction of the premixed combustion phase and injected fuel quantity during principal injection when a pilot injection is used. With triple injection for the tested engine load, the post-injection did not result in PM reduction since it contributes by itself to the PM production while the preinjection occurred too soon to burn conveniently and caused perturbations in the injection system as well. Using B20 blend in single injection caused a PM increase and a NOx reduction which might be explained by the poorer fuel atomization. However, pilot injection with B20 allowed to get a simultaneous reduction of NOx and PM, as observed with diesel. An injection simulation model was also developed and experimentally validated for different injection pressures as well as different energizing times and dwell times. When comparing the use of biodiesel with diesel, simulation showed that there was a critical energizing time for which both fuels yielded the same injection duration. For shorter energizing times, the biodiesel injection duration was shorter than for diesel, while longer energizing times presented the opposite behavior. The injection duration for the different blends falls between the pure-fuel situations. The use of constant properties (density, viscosity) and constant discharge coefficient showed no major loss in the precision of the flow-rate estimation, but revealed a great gain in calculus time. The use of pressure dependent bulk modulus and fluctuating injection pressure proved to be essential in order to have no drastic changes in the final predictions. Finally, the proposed model relevance in a case of engine testing was demonstrated with multiple injection strategies as well as with biodiesel since it allows a precise adjustment of the injection parameters while considering the dynamic effects caused by the injection. Keywords : Diesel engine, multiple injection, biodiesel, pollutant emission, heat release, mathematical model, injection simulation.

  5. Hydrologic monitoring of a waste-injection well near Milton, Florida, June 1975 - June 1977

    USGS Publications Warehouse

    Pascale, Charles A.; Martin, J.B.

    1978-01-01

    This report presents the hydraulic and chemical data collected from June 1, 1975, when injection began, to June 30, 1977 through a monitoring program at a deep-well waste-injection system at the American Cyanamid Company's plant near Milton, about 12 miles northwest of Pensacola. The injection system consists of a primary injection well, a standby injection well, and two deep monitor wells all completed open hole in the lower limestone of the Floridan aquifer and one shallow-monitor well completed in the upper limestone of the Floridan aquifer. Two of the monitor wells and the standby injection well are used to observe hydraulic and geochemical effects of waste injection in the injection zone at locations 8,180 feet northeast, 1,560 feet south, and 1,025 feet southwest of the primary injection well. The shallow-monitor well, used to observe any effects in the first permeable zone above the 200-foot-thick confining bed, is 28 feet north of the primary injection well. Since injection began in June 1975, 607 million gallons of treated industrial liquid waste with a pH of 4.6 to 6.3 and containing high concentrations of nitrate, organic nitrogen and carbon have been injected into a saline-water-filled limestone aquifer. Wellhead pressure at the injection well in June 1977 average 137 pounds per square inch and the hydraulic pressure gradient was 0.53 pound per square inch per foot of depth to the top of the injection zone. Water levels rose from 36 to 74 feet at the three wells used to monitor the injection zone during the 25-month period. The water level in the shallow-monitor well declined about 8 feet. No changes were detected in the chemical character of water from the shallow-monitor well and deep-monitor well-north. Increases in concentration of bicarbonate and dissolved organic carbon were detected in water from the deep-test monitor well in February 1976 and at the standby injection well in August 1976. In addition to increases in bicarbonate and dissolved organic carbon, sulfate, total organic nitrogen, and total nitrogen concentrations have also increased substantially in samples from these wells. Nitrogen gas concentrations in water samples collected at the three deep-monitor wells ranged from 19 to 176 milligrams per liter, methane from 4.5 to 11.4 milligrams per liter, and carbon dioxide from 7.7 to 44 milligrams per liter. The most probable number of denitrifying bacteria in water samples collected at the three deep-monitor wells ranged from less than 2 colonies to 17 colonies per 100 milliliters. None of the water samples collected in April 1977 at the three deep-monitor wells showed positive concentrations of acetone, ethanol, methanol, or acrylonitrile.

  6. Analysis of peptides using an integrated microchip HPLC-MS/MS system.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kirby, Brian J.; Chirica, Gabriela S.; Reichmuth, David S.

    Hyphendated LC-MS techniques are quickly becoming the standard tool for protemic analyses. For large homogeneous samples, bulk processing methods and capillary injection and separation techniques are suitable. However, for analysis of small or heterogeneous samples, techniques that can manipulate picoliter samples without dilution are required or samples will be lost or corrupted; further, static nanospray-type flowrates are required to maximize SNR. Microchip-level integration of sample injection with separation and mass spectrometry allow small-volume analytes to be processed on chip and immediately injected without dilution for analysis. An on-chip HPLC was fabricated using in situ polymerization of both fixed and mobilemore » polymer monoliths. Integration of the chip with a nanospray MS emitter enables identification of peptides by the use of tandem MS. The chip is capable of analyzing of very small sample volumes (< 200 pl) in short times (< 3 min).« less

  7. Remote beating of parallel or orthogonally polarized dual-wavelength optical carriers for 5G millimeter-wave radio-over-fiber link.

    PubMed

    Wang, Huai-Yung; Chi, Yu-Chieh; Lin, Gong-Ru

    2016-08-08

    A novel millimeter-wave radio over fiber (MMW-RoF) link at carrier frequency of 35-GHz is proposed with the use of remotely beating MMW generation from reference master and injected slave colorless laser diode (LD) carriers at orthogonally polarized dual-wavelength injection-locking. The slave colorless LD supports lasing one of the dual-wavelength master modes with orthogonal polarizations, which facilitates the single-mode direct modulation of the quadrature amplitude modulation (QAM) orthogonal frequency division multiplexing (OFDM) data. Such an injected single-carrier encoding and coupled dual-carrier transmission with orthogonal polarization effectively suppresses the cross-heterodyne mode-beating intensity noise, the nonlinear modulation (NLM) and four-wave mixing (FWM) sidemodes during injection locking and fiber transmission. In 25-km single-mode fiber (SMF) based wireline system, the dual-carrier under single-mode encoding provides baseband 24-Gbit/s 64-QAM OFDM transmission with an error vector magnitude (EVM) of 8.8%, a bit error rate (BER) of 3.7 × 10-3, a power penalty of <1.5 dB. After remotely self-beating for wireless transmission, the beat MMW carrier at 35 GHz can deliver the passband 16-QAM OFDM at 4 Gbit/s to show corresponding EVM and BER of 15.5% and 1.4 × 10-3, respectively, after 25-km SMF and 1.6-m free-space transmission.

  8. A single subcutaneous dose of tramadol for mild to moderate musculoskeletal trauma in the emergency department

    PubMed Central

    Cardozo, Alejandro; Silva, Carlos; Dominguez, Luis; Botero, Beatriz; Zambrano, Paulo; Bareno, Jose

    2014-01-01

    BACKGROUND: Mild to moderate musculoskeletal trauma is a common cause for an emergency room visit, and frequent pain is one of the cardinal symptoms of consultation. The objective of this study is to assess the perception of a single subcutaneous dose of 50 mg tramadol for pain management in patients with mild to moderate musculoskeletal trauma, likewise to appraise the perception of pain by subcutaneous injection. METHODS: A total of 77 patients, who met inclusion criteria, received a single subcutaneous dose of tramadol. Pain control was evaluated based on the verbal numerical pain scale (0–10) at baseline, 20 and 60 minutes; similarly, pain perception was evaluated secondary to subcutaneous injection of the analgesic. RESULTS: On admission, the average pain perceived by patients was 8; twenty minutes later, 89% of the patients reported five or less, and after sixty minutes, 94% had three or less on the verbal numerical pain scale. Of the patients, 88% reported pain perception by verbal numeric scale of 3 or less by injection of the drug, and 6.5% required a second analgesic for pain control. Two events with drug administration (soft tissue infection and mild abdominal rectus injection) were reported. CONCLUSION: We conclude that a single subcutaneous dose of tramadol is a safe and effective option for the management of patients with mild to moderate pain and musculoskeletal disease in the emergency department. PMID:25548601

  9. Early morphological nuclear events and developmental capacity of embryos reconstructed with fetal fibroblasts at the M or G1 phase after intracytoplasmic nuclear injection in cattle.

    PubMed

    Ideta, Atsushi; Urakawa, Manami; Aoyagi, Yoshito; Saeki, Kazuhiro

    2005-04-01

    We examined morphological nuclear events during the first cell cycle of bovine embryos reconstructed with somatic cells at the M and G1 phases (M-embryos and G1-embryos, respectively) by intracytoplasmic nuclear injection, and the subsequent development of these embryos in vitro and in vivo. Bovine fetal fibroblasts (BFFs) at the M or G1 phase were directly injected into enucleated oocytes, and activated immediately. Only half (48%) of the M-embryos extruded polar body-like cells (PBCs) at 6 h post injection (hpi). At 15 to 19 hpi, 54% of the M-embryos formed a single pronucleus-like nucleus. Nuclear envelope-breakdown, premature chromosome condensation and single nuclear clusters were observed in most of the G1-embryos (88%) within 30 min following the nuclear injection. At 15 to 19 hpi, single pronucleus-like nuclei were formed in most G1-embryos (83%). The potential of G1-embryos to develop to blastocysts was significantly higher than that of M-embryos (31% vs 16%). Three of five recipients following transfer of blastocysts derived from the G1-embryos became pregnant on Day 30, and one recipient delivered a calf. Our results indicate that almost a half of the M-embryos failed to extrude PBCs and that the G1-embryos developed to blastocysts at a higher rate than the M-embryos.

  10. The effects of subarachnoid administration of preservative-free S(+)-ketamine on spinal cord and meninges in dogs.

    PubMed

    Rojas, Alfredo Cury; Alves, Juliana Gaiotto; Moreira E Lima, Rodrigo; Esther Alencar Marques, Mariângela; Moreira de Barros, Guilherme Antônio; Fukushima, Fernanda Bono; Modolo, Norma Sueli Pinheiro; Ganem, Eliana Marisa

    2012-02-01

    The N-methyl-d-aspartate receptor antagonist ketamine and its active enantiomer, S(+)-ketamine, have been injected in the epidural and subarachnoid spaces to treat acute postoperative pain and relieve neuropathic pain syndrome. In this study we evaluated the effects of a single dose of preservative-free S(+)-ketamine, in doses usually used in clinical practice, in the spinal cord and meninges of dogs. Under anesthesia (IV etomidate (2 mg/kg) and fentanyl (0.005 mg/kg), 16 dogs (6 to 15 kg) were randomized to receive a lumbar intrathecal injection (L5/6) of saline solution of 0.9% (control group) or S(+)-ketamine 1 mg/kg(-1) (ketamine group). All doses were administered in a volume of 1 mL over a 10-second interval. Accordingly, injection solution ranged from 0.6% to 1.5%. After 21 days of clinical observation, the animals were killed; spinal cord, cauda equina root, and meninges were removed for histological examination with light microscopy. Tissues were examined for demyelination (Masson trichrome), neuronal death (hematoxylin and eosin) and astrocyte activation (glial fibrillary acidic protein). No clinical or histological alterations of spinal tissue or meninges were found in animals from either control or ketamine groups. A single intrathecal injection of preservative-free S(+)-ketamine, at 1 mg/kg(-1) dosage, over a concentration range of 6 to 15 mg/mL injected in the subarachnoid space in a single puncture, did not produce histological alterations in this experimental model.

  11. The protective effect of pomegranate extract against cisplatin toxicity in rat liver and kidney tissue.

    PubMed

    Bakır, Salih; Yazgan, Ümit Can; İbiloğlu, İbrahim; Elbey, Bilal; Kızıl, Murat; Kelle, Mustafa

    2015-01-01

    The purpose of this study was to perform a histopathological investigation, at the light microscopy level, of the protective effects of pomegranate extract in cisplatin-induced liver and kidney damage in rats. Twenty-eight adult male Wistar albino rats were randomly divided into four groups of seven animals: Group 1: Control; Group 2: Treated for 10 consecutive days by gavage with pomegranate juice (2 ml/kg/day); Group 3: Injected intraperitoneally with cisplatin (8 mg/kg body weight, single dose) onset of the day 5, and Group 4: Treated by gavage with pomegranate juice 10 days before and after a single injection of cisplatin onset of the day 5. After 10 days, the animals were sacrificed and their kidneys and liver tissue samples were removed from each animal after experimental procedures. Cisplatin-induced renal and hepatic toxicity and the effect of pomegranate juice were evaluated by histopatological examinations. In the kidney tissue, pomegranate juice significantly ameliorated cisplatin-induced structural alterations when compared with the cisplatin alone group. But in the liver tissue, although pomegranate juice attenuated the cisplatin-induced toxicity only in two rats, significant improvement was not observed. In conclusion, these results demonstrate that the anti-oxidant pomegranate juice might have a protective effect against cisplatin-induced toxicity in rat kidney, but not in liver. Pomegranate juice could be beneficial as a dietary supplement in patients receiving chemotherapy medications.

  12. Injection blow moulding single stage process: Validation of the numerical simulation through tomography analysis

    NASA Astrophysics Data System (ADS)

    Biglione, Jordan; Béreaux, Yves; Charmeau, Jean-Yves

    2016-10-01

    The injection blow moulding single stage process has been made available on standard injection moulding machine. Both the injection moulding stage and the blow moulding stage are being taken care of in an injection mould. Thus the dimensions of this mould are those of a conventional injection moulding mould. The fact that the two stages are located in the same mould leads to a process more constrained than the conventional one. This process introduces temperature gradients, molecular orientation, high stretch rates and high cooling rates. These constraints lead to a small processing window. In practice, the preform has to remain sufficiently melted to be blown so that the process takes place between the melting temperature and the crystallization temperature. In our numerical approach, the polymer is supposed to be blown in its molten state. Hence we have identified the mechanical behaviour of the polymer in its molten state through dynamical rheology experiments. A viscous Cross model has been proved to be relevant to the problem. Thermal dependence is assumed by an Arrhenius law. The process is simulated through a finite element code (POLYFLOW software) in the Ansys Workbench framework. Thickness measurements using image analysis of tomography data are performed and comparisons with the simulation results show good agreements.

  13. [Intra-amniotic administration of prostaglandin F 2 alpha, 12-methyl-prostaglandin F 2 alpha and hypertonic sodium chloride solution for induction of abortion in second-trimester pregnancy].

    PubMed

    Persianinov, L S; Chernukha, E A

    1975-01-01

    The authors had performed comperative studies of the effect of the induction of abortion in late pregnancy according to the medical indications by intra-amniotic injection of 20% hypertonic NaCl saline in 26 pregnant patients, of 25 mg prostaglandin F2alpha with 6 hours' intervals in 25 patients, a single dose injection of 40 mg PGF2alpha in 27 cases and single dose injection of 2,5 mg 15-me-PGF2alpha given to 25 patients. The highest success rate was obtained with the single dose injection of 2,5 mg 15-me-PGF2alpha and the lowest success rate was obtained with 25 mg prostaglandin F2alpha with 6 hours' intervals. Despite of rather high procentage of success rate in using the hypertonic NaCl saline, this method is more dangerous in the moment of the injection of saline and complications during the abortion (water intoxication, necrosis of tissue, coagulation defects and other). The most frequently incountered side-effects in using PGs were vomiting and diarhea. Histologic examinations of the placenta revealed massive bleedings, at frequency rate being the same for prostaglandins and the hypertonic saline. The degree of isoimmunisation was lower with prostaglandins than with hypertonic NaCl saline, despite of the late dates of pregnancy termination. The intro-amniotic injection of the small volume solution of 15-me-PGF2alpha or PGF2alpha is more simpler and easier from the technical point of view than any methodic recommended for using saline and at the same time it is more effective.

  14. Refrigeration system with a compressor-pump unit and a liquid-injection desuperheating line

    DOEpatents

    Gaul, Christopher J.

    2001-01-01

    The refrigeration system includes a compressor-pump unit and/or a liquid-injection assembly. The refrigeration system is a vapor-compression refrigeration system that includes an expansion device, an evaporator, a compressor, a condenser, and a liquid pump between the condenser and the expansion device. The liquid pump improves efficiency of the refrigeration system by increasing the pressure of, thus subcooling, the liquid refrigerant delivered from the condenser to the expansion device. The liquid pump and the compressor are driven by a single driving device and, in this regard, are coupled to a single shaft of a driving device, such as a belt-drive, an engine, or an electric motor. While the driving device may be separately contained, in a preferred embodiment, the liquid pump, the compressor, and the driving device (i.e., an electric motor) are contained within a single sealable housing having pump and driving device cooling paths to subcool liquid refrigerant discharged from the liquid pump and to control the operating temperature of the driving device. In another aspect of the present invention, a liquid injection assembly is included in a refrigeration system to divert liquid refrigerant from the discharge of a liquid pressure amplification pump to a compressor discharge pathway within a compressor housing to desuperheat refrigerant vapor to the saturation point within the compressor housing. The liquid injection assembly includes a liquid injection pipe with a control valve to meter the volume of diverted liquid refrigerant. The liquid injection assembly may also include a feedback controller with a microprocessor responsive to a pressure sensor and a temperature sensor both positioned between the compressor to operate the control valve to maintain the refrigerant at or near saturation.

  15. Widespread spinal cord transduction by intrathecal injection of rAAV delivers efficacious RNAi therapy for amyotrophic lateral sclerosis.

    PubMed

    Wang, Hongyan; Yang, Bin; Qiu, Linghua; Yang, Chunxing; Kramer, Joshua; Su, Qin; Guo, Yansu; Brown, Robert H; Gao, Guangping; Xu, Zuoshang

    2014-02-01

    Amyotrophic lateral sclerosis (ALS) causes motor neuron degeneration and paralysis. No treatment can significantly slow or arrest the disease progression. Mutations in the SOD1 gene cause a subset of familial ALS by a gain of toxicity. In principle, these cases could be treated with RNAi that destroys the mutant mRNA, thereby abolishing the toxic protein. However, no system is available to efficiently deliver the RNAi therapy. Recombinant adenoassociated virus (rAAV) is a promising vehicle due to its long-lasting gene expression and low toxicity. However, ALS afflicts broad areas of the central nervous system (CNS). A lack of practical means to spread rAAV broadly has hindered its application in treatment of ALS. To overcome this barrier, we injected several rAAV serotypes into the cerebrospinal fluid. We found that some rAAV serotypes such as rAAVrh10 and rAAV9 transduced cells throughout the length of the spinal cord following a single intrathecal injection and in the broad forebrain following a single injection into the third ventricle. Furthermore, a single intrathecal injection of rAAVrh10 robustly transduced motor neurons throughout the spinal cord in a non-human primate. These results suggested a therapeutic potential of this vector for ALS. To test this, we injected a rAAVrh10 vector that expressed an artificial miRNA targeting SOD1 into the SOD1G93A mice. This treatment knocked down the mutant SOD1 expression and slowed the disease progression. Our results demonstrate the potential of rAAVs for delivering gene therapy to treat ALS and other diseases that afflict broad areas of the CNS.

  16. Impact of CO2 injection protocol on fluid-solid reactivity: high-pressure and temperature microfluidic experiments in limestone

    NASA Astrophysics Data System (ADS)

    Jimenez-Martinez, Joaquin; Porter, Mark; Carey, James; Guthrie, George; Viswanathan, Hari

    2017-04-01

    Geological sequestration of CO2 has been proposed in the last decades as a technology to reduce greenhouse gas emissions to the atmosphere and mitigate the global climate change. However, some questions such as the impact of the protocol of CO2 injection on the fluid-solid reactivity remain open. In our experiments, two different protocols of injection are compared at the same conditions (8.4 MPa and 45 C, and constant flow rate 0.06 ml/min): i) single phase injection, i.e., CO2-saturated brine; and ii) simultaneous injection of CO2-saturated brine and scCO2. For that purpose, we combine a unique high-pressure/temperature microfluidics experimental system, which allows reproducing geological reservoir conditions in geo-material substrates (i.e., limestone, Cisco Formation, Texas, US) and high resolution optical profilometry. Single and multiphase flow through etched fracture networks were optically recorded with a microscope, while processes of dissolution-precipitation in the etched channels were quantified by comparison of the initial and final topology of the limestone micromodels. Changes in hydraulic conductivity were quantified from pressure difference along the micromodel. The simultaneous injection of CO2-saturated brine and scCO2, reduced the brine-limestone contact area and also created a highly heterogeneous velocity field (i.e., low velocities regions or stagnation zones, and high velocity regions or preferential paths), reducing rock dissolution and enhancing calcite precipitation. The results illustrate the contrasting effects of single and multiphase flow on chemical reactivity and suggest that multiphase flow by isolating parts of the flow system can enhance CO2 mineralization.

  17. Differentiating organic from conventional peppermints using chromatographic and flow-injection mass spectrometric (FIMS) fingerprints

    USDA-ARS?s Scientific Manuscript database

    High performance liquid chromatography (HPLC) and flow-injection mass spectrometric (FIMS) fingerprinting techniques were tested for their potential in differentiating organic and conventional peppermint samples. Ten organic and ten conventional peppermint samples were examined using HPLC-UV and FI...

  18. Effectiveness of Shield Termination Techniques Tested with TEM Cell and Bulk Current Injection

    NASA Technical Reports Server (NTRS)

    Bradley, Arthur T.; Hare, Richard J.

    2009-01-01

    This paper presents experimental results of the effectiveness of various shield termination techniques. Each termination technique is evaluated by two independent noise injection methods; transverse electromagnetic (TEM) cell operated from 3 MHz 400 MHz, and bulk current injection (BCI) operated from 50 kHz 400 MHz. Both single carrier and broadband injection tests were investigated. Recommendations as to how to achieve the best shield transfer impedance (i.e. reduced coupled noise) are made based on the empirical data. Finally, the noise injection techniques themselves are indirectly evaluated by comparing the results obtained from the TEM Cell to those from BCI.

  19. Turbine vane leading edge gas film cooling with spanwise angled coolant holes

    NASA Technical Reports Server (NTRS)

    Hanus, G. J.; Lecuyer, M. R.

    1976-01-01

    An experimental film cooling study was conducted on a 3x size model turbine vane. Injection at the leading edge was from a single row of holes angled in a spanwise direction for two configurations of holes at 18 or 35 deg to the surface. The reduction in the local Stanton number for injection at a coolant-to-mainstream density ratio of 2.18 was calculated from heat flux measurements downstream of injection. Results indicate that optimum cooling occurs near a coolant-to-mainstream velocity ratio of 0.5. Shallow injection angles appear to be most beneficial when injecting into a highly accelerated mainstream.

  20. Spin-injection into epitaxial graphene on silicon carbide

    NASA Astrophysics Data System (ADS)

    Konishi, Keita; Cui, Zhixin; Hiraki, Takahiro; Yoh, Kanji

    2013-09-01

    We have studied the spin-injection properties in epitaxial graphene on SiC. The ferromagnetic metal (FM) electrodes were composed of a tunnel barrier layer AlOx (14 Å) and a ferromagnetic Co (600 Å) layer. We have successfully observed the clear resistance peaks indicating spin-injection both in the "local" and "non-local" spin measurement set-ups at low temperatures. We estimate spin-injection rate of 1% based on "non-local" measurement and 1.6% based on local measurements. Spin-injection rate of multilayer graphene by mechanical exfoliation method was twice as high as single layer graphene on SiC based on "local" measurement.

  1. Evaluation of Water Injection Effect on NO(x) Formation for a Staged Gas Turbine Combustor

    NASA Technical Reports Server (NTRS)

    Fan, L.; Yang, S. L.; Kundu, K. P.

    1996-01-01

    NO(x) emission control by water injection on a staged turbine combustor (STC) was modeled using the KIVA-2 code with modification. Water is injected into the rich-burn combustion zone of the combustor by a single nozzle. Parametric study for different water injection patterns was performed. Results show NO(x) emission will decrease after water being injected. Water nozzle location also has significant effect for NO formation and fuel ignition. The chemical kinetic model is also sensitive to the excess water. Through this study, a better understanding of the physics and chemical kinetics is obtained, this will enhance the STC design process.

  2. Fluorescent blue lights, injecting drug use and related health risk in public conveniences: findings from a qualitative study of micro-injecting environments.

    PubMed

    Parkin, Stephen; Coomber, Ross

    2010-07-01

    This paper presents findings relating to injecting drug users' experiences and opinions of public toilets illuminated with fluorescent blue lights and presents an empirical assessment of the intended deterrent effect of such installations. Data analysis identified that blue lights deterred less than half the sample interviewed. Furthermore over half (18/31) of the sample were prepared to inject in conditions specifically designed to deter injecting practice. Of these, 11 respondents were completely undeterred and 7 individuals were only partially deterred by blue light environments. These findings are discussed within the interpretative frameworks of Pierre Bourdieu's theory of habitus and symbolic violence. The authors conclude that fluorescent blue lights contribute towards the development of situated resistance by injecting drug users within a public injecting habitus; a resistance that produces and reproduces drug-related harm and is a behaviour that opposes the symbolic violence of harm reduction intervention. The paper concludes with suggestions for theory-driven practical intervention that may seek to disrupt the harmful elements of the public injecting habitus. 2010 Elsevier Ltd. All rights reserved.

  3. Effect of the number and position of nozzle holes on in- and near-nozzle dynamic characteristics of diesel injection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moon, Seoksu; Gao, Yuan; Park, Suhan

    Despite the fact that all modern diesel engines use multi-hole injectors, single-hole injectors are frequently used to understand the fundamental properties of high-pressure diesel injections due to their axisymmetric design of the injector nozzles. A multi-hole injector accommodates many holes around the nozzle axis to deliver adequate amount of fuel with small orifices. The off-axis arrangement of the multi-hole injectors significantly alters the inter- and near-nozzle flow patterns compared to those of the single-hole injectors. This study compares the transient needle motion and near-nozzle flow characteristics of the single- and multi-hole (3-hole and 6-hole) diesel injectors to understand how themore » difference in hole arrangement and number affects the initial flow development of the diesel injectors. A propagation-based X-ray phase-contrast imaging technique was applied to compare the transient needle motion and near-nozzle flow characteristics of the single- and multi-hole injectors. The comparisons were made by dividing the entire injection process by three sub-stages: opening-transient, quasi-steady and closing-transient. (C) 2015 Elsevier Ltd. All rights reserved.« less

  4. High variability of HIV and HCV seroprevalence and risk behaviours among people who inject drugs: results from a cross-sectional study using respondent-driven sampling in eight German cities (2011-14).

    PubMed

    Wenz, Benjamin; Nielsen, Stine; Gassowski, Martyna; Santos-Hövener, Claudia; Cai, Wei; Ross, R Stefan; Bock, Claus-Thomas; Ratsch, Boris-Alexander; Kücherer, Claudia; Bannert, Norbert; Bremer, Viviane; Hamouda, Osamah; Marcus, Ulrich; Zimmermann, Ruth

    2016-09-05

    People who inject drugs (PWID) are at increased risk of acquiring and transmitting HIV and Hepatitis C (HCV) due to sharing injection paraphernalia and unprotected sex. To generate seroprevalence data on HIV and HCV among PWID and related data on risk behaviour, a multicentre sero- and behavioural survey using respondent driven sampling (RDS) was conducted in eight German cities between 2011 and 2014. We also evaluated the feasibility and effectiveness of RDS for recruiting PWID in the study cities. Eligible for participation were people who had injected drugs within the last 12 months, were 16 years or older, and who consumed in one of the study cities. Participants were recruited, using low-threshold drop-in facilities as study sites. Initial seeds were selected to represent various sub-groups of people who inject drugs (PWID). Participants completed a face-to-face interview with a structured questionnaire about socio-demographics, sexual and injecting risk behaviours, as well as the utilisation of health services. Capillary blood samples were collected as dried blood spots and were anonymously tested for serological and molecular markers of HIV and HCV. The results are shown as range of proportions (min. and max. values (%)) in the respective study cities. For evaluation of the sampling method we applied criteria from the STROBE guidelines. Overall, 2,077 PWID were recruited. The range of age medians was 29-41 years, 18.5-35.3 % of participants were female, and 9.2-30.6 % were foreign born. Median time span since first injection were 10-18 years. Injecting during the last 30 days was reported by 76.0-88.4 % of participants. Sharing needle/syringes (last 30 days) ranged between 4.7 and 22.3 %, while sharing unsterile paraphernalia (spoon, filter, water, last 30 days) was reported by 33.0-43.8 %. A majority of participants (72.8-85.8 %) reported incarceration at least once, and 17.8-39.8 % had injected while incarcerated. Between 30.8 and 66.2 % were currently in opioid substitution therapy. Unweighted HIV seroprevalence ranged from 0-9.1 %, HCV from 42.3-75.0 %, and HCV-RNA from 23.1-54.0 %. The implementation of RDS as a recruiting method in cooperation with low-threshold drop in facilities was well accepted by both staff and PWID. We reached our targeted sample size in seven of eight cities. In the recruited sample of mostly current injectors with a long duration of injecting drug use, seroprevalence for HIV and HCV varied greatly between the city samples. HCV was endemic among participants in all city samples. Our results demonstrate the necessity of intensified prevention strategies for blood-borne infections among PWID in Germany.

  5. Single-frequency operation of diode-pumped 2 microm Q-switched Tm:YAG laser injection seeded by monolithic nonplanar ring laser.

    PubMed

    Gao, Chunqing; Lin, Zhifeng; Gao, Mingwei; Zhang, Yunshan; Zhu, Lingni; Wang, Ran; Zheng, Yan

    2010-05-20

    We present a diode-pumped, 2mum single-frequency Q-switched Tm:YAG laser. The Q-switched laser is injection seeded by a monolithic Tm:YAG nonplanar ring oscillator with the ramp-hold-fire technique. The output energy of the 2mum single-frequency Q-switched pulse is 2.23mJ, with a pulse width of 290ns and a repetition rate of 200Hz. From the heterodyne beating measurement, the frequency difference between the seed laser and the Q-switched laser is determined to be 37.66MHz, with a half-width of the symmetric spectrum of about 2 MHz.

  6. Discrete innervation of murine taste buds by peripheral taste neurons.

    PubMed

    Zaidi, Faisal N; Whitehead, Mark C

    2006-08-09

    The peripheral taste system likely maintains a specific relationship between ganglion cells that signal a particular taste quality and taste bud cells responsive to that quality. We have explored a measure of the receptoneural relationship in the mouse. By injecting single fungiform taste buds with lipophilic retrograde neuroanatomical markers, the number of labeled geniculate ganglion cells innervating single buds on the tongue were identified. We found that three to five ganglion cells innervate a single bud. Injecting neighboring buds with different color markers showed that the buds are primarily innervated by separate populations of geniculate cells (i.e., multiply labeled ganglion cells are rare). In other words, each taste bud is innervated by a population of neurons that only connects with that bud. Palate bud injections revealed a similar, relatively exclusive receptoneural relationship. Injecting buds in different regions of the tongue did not reveal a topographic representation of buds in the geniculate ganglion, despite a stereotyped patterned arrangement of fungiform buds as rows and columns on the tongue. However, ganglion cells innervating the tongue and palate were differentially concentrated in lateral and rostral regions of the ganglion, respectively. The principal finding that small groups of ganglion cells send sensory fibers that converge selectively on a single bud is a new-found measure of specific matching between the two principal cellular elements of the mouse peripheral taste system. Repetition of the experiments in the hamster showed a more divergent innervation of buds in this species. The results indicate that whatever taste quality is signaled by a murine geniculate ganglion neuron, that signal reflects the activity of cells in a single taste bud.

  7. Sequential injection spectrophotometric determination of oxybenzone in lipsticks.

    PubMed

    Salvador, A; Chisvert, A; Camarasa, A; Pascual-Martí, M C; March, J G

    2001-08-01

    A sequential injection (SI) procedure for the spectrophotometric determination of oxybenzone in lipsticks is reported. The colorimetric reaction between nickel and oxybenzone was used. SI parameters such as sample solution volume, reagent solution volume, propulsion flow rate and reaction coil length were studied. The limit of detection was 3 microg ml(-1). The sensitivity was 0.0108+/-0.0002 ml microg(-1). The relative standard deviations of the results were between 6 and 12%. The real concentrations of samples and the values obtained by HPLC were comparable. Microwave sample pre-treatment allowed the extraction of oxybenzone with ethanol, thus avoiding the use of toxic organic solvents. Ethanol was also used as carrier in the SI system. Seventy-two injections per hour can be performed, which means a sample frequency of 24 h(-1) if three replicates are measured for each sample.

  8. Employment-Based Reinforcement of Adherence to Depot Naltrexone in Unemployed Opioid-Dependent Adults: A Randomized Controlled Trial

    PubMed Central

    Everly, Jeffrey J.; DeFulio, Anthony; Koffarnus, Mikhail N.; Leoutsakos, Jeannie-Marie S.; Donlin, Wendy D.; Aklin, Will M.; Umbricht, Annie; Fingerhood, Michael; Bigelow, George E.; Silverman, Kenneth

    2011-01-01

    Aims Naltrexone can be used to treat opioid dependence, but patients refuse to take it. Extended-release depot formulations may improve adherence, but long-term adherence rates to depot naltrexone are not known. This study determined long-term rates of adherence to depot naltrexone and whether employment-based reinforcement can improve adherence. Design Participants who were inducted onto oral naltrexone were randomly assigned to Contingency (n=18) or Prescription (n=17) groups. Participants were offered six depot naltrexone injections and invited to work at the therapeutic workplace weekdays for 26 weeks where they earned stipends for participating in job skills training. Contingency participants were required to accept naltrexone injections to maintain workplace access and to maintain maximum pay. Prescription participants could work independent of whether they accepted injections. Setting The therapeutic workplace, a model employment-based intervention for drug addiction and unemployment. Participants Opioid-dependent unemployed adults. Measurements Depot naltrexone injections accepted and opiate-negative urine samples. Findings Contingency participants accepted significantly more naltrexone injections than Prescription participants (81% versus 42%), and were more likely to accept all injections (66% versus 35%). At monthly assessments (with missing urine samples imputed as positive), the groups provided similar percentages of samples negative for opiates (74% versus 62%) and for cocaine (56% versus 54%). Opiate positive samples were more likely when samples were also positive for cocaine. Conclusions Employment-based reinforcement can maintain adherence to depot naltrexone. Future research should determine whether persistent cocaine use compromises naltrexone's effect on opiate use. Workplaces may be useful for promoting sustained adherence to depot naltrexone. PMID:21320227

  9. Quantitative X-ray measurements of high-pressure fuel sprays from a production heavy duty diesel injector

    NASA Astrophysics Data System (ADS)

    Ramírez, A. I.; Som, S.; Aggarwal, Suresh K.; Kastengren, A. L.; El-Hannouny, E. M.; Longman, D. E.; Powell, C. F.

    2009-07-01

    A quantitative and time-resolved X-ray radiography technique has been used for detailed measurements of high-pressure fuel sprays in the near-nozzle region of a diesel engine injector. The technique provides high spatial and temporal resolution, especially in the relatively dense core region. A single spray plume from a hydraulically actuated electronically controlled unit injector model 315B injector with a 6-hole nozzle was isolated and studied at engine-like densities for two different injection pressures. Optical spray imaging was also employed to evaluate the effectiveness of the shield used to isolate a single spray plume. The steady state fuel distributions for both injection pressures are similar and show a dense spray region along the axis of the spray, with the on-axis spray density decreasing as the spray progresses downstream. The higher injection pressure case exhibits a larger cone angle and spray broadening at the exit of the nozzle. For some time periods, the near-nozzle penetration speed is lower for the high injection pressure case than the low injection pressure case, which is unexpected, but can be attributed to the needle and flow dynamics inside the injector causing slower pressure build-up for the former case. Rate of injection testing was performed to further understand near-nozzle behavior. Mass distribution data were obtained and used to find mass-averaged velocity of the spray. Comparisons of the radiography data with that from a common rail single-hole light duty injectors under similar injection conditions show several significant differences. The current data show a larger cone angle and lower penetration speed than that from the light-duty injector. Moreover, these data display a Gaussian mass distribution across the spray near the injector, whereas in previous light-duty injector measurements, the mass distribution had steeper sides and a flatter peak. Measurements are also used to examine the spray models in the STAR-CD software.

  10. Intra-Arterial Delivery of AAV Vectors to the Mouse Brain After Mannitol Mediated Blood Brain Barrier Disruption

    PubMed Central

    Santillan, Alejandro; Sondhi, Dolan; Dyke, Jonathan P.; Crystal, Ronald G.; Gobin, Y. Pierre; Ballon, Douglas J.

    2014-01-01

    The delivery of therapeutics to neural tissue is greatly hindered by the blood brain barrier (BBB). Direct local delivery via diffusive release from degradable implants or direct intra-cerebral injection can bypass the BBB and obtain high concentrations of the therapeutic in the targeted tissue, however the total volume of tissue that can be treated using these techniques is limited. One treatment modality that can potentially access large volumes of neural tissue in a single treatment is intra-arterial (IA) injection after osmotic blood brain barrier disruption. In this technique, the therapeutic of interest is injected directly into the arteries that feed the target tissue after the blood brain barrier has been disrupted by exposure to a hyperosmolar mannitol solution, permitting the transluminal transport of the therapy. In this work we used contrast enhanced magnetic resonance imaging (MRI) studies of IA injections in mice to establish parameters that allow for extensive and reproducible BBB disruption. We found that the volume but not the flow rate of the mannitol injection has a significant effect on the degree of disruption. To determine whether the degree of disruption we observed with this method was sufficient for delivery of nanoscale therapeutics, we performed IA injections of an adeno-associated viral vector containing the CLN2 gene (AAVrh.10CLN2), which is mutated in the lysosomal storage disorder Late Infantile Neuronal Ceroid Lipofuscinosis (LINCL). We demonstrated that IA injection of AAVrh.10CLN2 after BBB disruption can achieve widespread transgene production in the mouse brain after a single administration. Further, we showed that there exists a minimum threshold of BBB disruption necessary to permit the AAV.rh10 vector to pass into the brain parenchyma from the vascular system. These results suggest that IA administration may be used to obtain widespread delivery of nanoscale therapeutics throughout the murine brain after a single administration. PMID:25270115

  11. 21 CFR 522.2005 - Propofol injection.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... indicated for use as an anesthetic as follows: As a single injection to provide general anesthesia for procedures lasting up to 5 minutes; for induction and maintenance of general anesthesia using incremental doses to effect; for induction of general anesthesia where maintenance is provided by inhalant...

  12. Self-injection locked blue laser

    NASA Astrophysics Data System (ADS)

    Donvalkar, Prathamesh S.; Savchenkov, Anatoliy; Matsko, Andrey

    2018-04-01

    We demonstrate a 446.5 nm GaN semiconductor laser with sub-MHz linewidth. The linewidth reduction is achieved by locking the laser to a magnesium fluoride whispering gallery mode resonator characterized with 109 quality factor. Self-injection locking ensures single longitudinal mode operation of the laser.

  13. Basic requirements of fuel-injection nozzles for quiescent combustion chambers

    NASA Technical Reports Server (NTRS)

    Spanogle, J A; Foster, H H

    1931-01-01

    This report presents test results obtained during an investigation of the performance of a single-cylinder, high-speed, compression-ignition test engine when using multiple-orifice fuel-injection valve nozzles in which the number and the direction of the orifices were varied independently.

  14. Single step production of Cas9 mRNA for zygote injection.

    PubMed

    Redel, Bethany K; Beaton, Benjamin P; Spate, Lee D; Benne, Joshua A; Murphy, Stephanie L; O'Gorman, Chad W; Spate, Anna M; Prather, Randall S; Wells, Kevin D

    2018-03-01

    Production of Cas9 mRNA in vitro typically requires the addition of a 5´ cap and 3´ polyadenylation. A plasmid was constructed that harbored the T7 promoter followed by the EMCV IRES and a Cas9 coding region. We hypothesized that the use of the metastasis associated lung adenocarcinoma transcript 1 (Malat1) triplex structure downstream of an IRES/Cas9 expression cassette would make polyadenylation of in vitro produced mRNA unnecessary. A sequence from the mMalat1 gene was cloned downstream of the IRES/Cas9 cassette described above. An mRNA concentration curve was constructed with either commercially available Cas9 mRNA or the IRES/ Cas9/triplex, by injection into porcine zygotes. Blastocysts were genotyped to determine if differences existed in the percent of embryos modified. The concentration curve identified differences due to concentration and RNA type injected. Single step production of Cas9 mRNA provides an alternative source of Cas9 for use in zygote injections.

  15. Single-Layer Halide Perovskite Light-Emitting Diodes with Sub-Band Gap Turn-On Voltage and High Brightness.

    PubMed

    Li, Junqiang; Shan, Xin; Bade, Sri Ganesh R; Geske, Thomas; Jiang, Qinglong; Yang, Xin; Yu, Zhibin

    2016-10-03

    Charge-carrier injection into an emissive semiconductor thin film can result in electroluminescence and is generally achieved by using a multilayer device structure, which requires an electron-injection layer (EIL) between the cathode and the emissive layer and a hole-injection layer (HIL) between the anode and the emissive layer. The recent advancement of halide perovskite semiconductors opens up a new path to electroluminescent devices with a greatly simplified device structure. We report cesium lead tribromide light-emitting diodes (LEDs) without the aid of an EIL or HIL. These so-called single-layer LEDs have exhibited a sub-band gap turn-on voltage. The devices obtained a brightness of 591 197 cd m -2 at 4.8 V, with an external quantum efficiency of 5.7% and a power efficiency of 14.1 lm W -1 . Such an advancement demonstrates that very high efficiency of electron and hole injection can be obtained in perovskite LEDs even without using an EIL or HIL.

  16. Effect of Moderate Air Flow on the Distribution of Fuel Sprays After Injection Cut-0ff

    NASA Technical Reports Server (NTRS)

    Rothrock, A M; Spencer, R C

    1935-01-01

    High-speed motion pictures were taken of fuel sprays with the NACA spray-photographic apparatus to study the distribution of the liquid fuel from the instant of injection cut-off until about 0.05 second later. The fuel was injected into a glass-walled chamber in which the air density was varied from 1 to 13 times atmospheric air density (0.0765 to 0.99 pound per cubic foot) and in which the air was at room temperature. The air in the chamber was set in motion by means of a fan, and was directed counter to the spray at velocities up to 27 feet per second. The injection pressure was varied from 2,000 to 6,000 pounds per square inch. A 0.20-inch single-orifice nozzle, an 0.008-inch single-orifice nozzle, a multiorifice nozzle, and an impinging-jets nozzle were used. The best distribution was obtained by the use of air and a high-dispersion nozzle.

  17. Single injection of platelet-rich plasma as a novel treatment of carpal tunnel syndrome.

    PubMed

    Malahias, Michael Alexander; Johnson, Elizabeth O; Babis, George C; Nikolaou, Vasileios S

    2015-11-01

    Both in vitro and in vivo experiments have confirmed that platelet-rich plasma has therapeutic effects on many neuropathies, but its effects on carpal tunnel syndrome remain poorly understood. We aimed to investigate whether single injection of platelet-rich plasma can improve the clinical symptoms of carpal tunnel syndrome. Fourteen patients presenting with median nerve injury who had suffered from mild carpal tunnel syndrome for over 3 months were included in this study. Under ultrasound guidance, 1-2 mL of platelet-rich plasma was injected into the region around the median nerve at the proximal edge of the carpal tunnel. At 1 month after single injection of platelet-rich plasma, Visual Analogue Scale results showed that pain almost disappeared in eight patients and it was obviously alleviated in three patients. Simultaneously, the disabilities of the arm, shoulder and hand questionnaire showed that upper limb function was obviously improved. In addition, no ultrasonographic manifestation of the carpal tunnel syndrome was found in five patients during ultrasonographic measurement of the width of the median nerve. During 3-month follow-up, the pain was not greatly alleviated in three patients. These findings show very encouraging mid-term outcomes regarding use of platelet-rich plasma for the treatment of carpal tunnel syndrome.

  18. A single injection of the anabolic bone agent, parathyroid hormone-collagen binding domain (PTH-CBD), results in sustained increases in bone mineral density for up to 12 months in normal female mice.

    PubMed

    Ponnapakkam, Tulasi; Katikaneni, Ranjitha; Suda, Hirofumi; Miyata, Shigeru; Matsushita, Osamu; Sakon, Joshua; Gensure, Robert C

    2012-09-01

    Parathyroid hormone (PTH) is the most effective osteoporosis treatment, but it is only effective if administered by daily injections. We fused PTH(1-33) to a collagen binding domain (PTH-CBD) to extend its activity, and have shown an anabolic bone effect with monthly dosing. We tested the duration of action of this compound with different routes of administration. Normal young C57BL/6J mice received a single intraperitoneal injection of PTH-CBD (320 μg/kg). PTH-CBD treated mice showed a 22.2 % increase in bone mineral density (BMD) at 6 months and 12.8 % increase at 12 months. When administered by subcutaneous injection, PTH-CBD again caused increases in BMD, 15.2 % at 6 months and 14.3 % at 12 months. Radiolabeled PTH-CBD was concentrated in bone and skin after either route of administration. We further investigated skin effects of PTH-CBD, and histological analysis revealed an apparent increase in anagen VI hair follicles. A single dose of PTH-CBD caused sustained increases in BMD by >10 % for 1 year in normal mice, regardless of the route of administration, thus showing promise as a potential osteoporosis therapy.

  19. Optically detected, single nanoparticle mass spectrometer with pre-filtered electrospray nanoparticle source

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Howder, Collin R.; Bell, David M.; Anderson, Scott L.

    2014-01-15

    An instrument designed for non-destructive mass analysis of single trapped nanoparticles is described. The heart of the instrument is a 3D quadrupole (Paul) trap constructed to give optical access to the trap center along ten directions, allowing passage of lasers for particle heating and detection, particle injection, collection of scattered or fluorescent photons for particle detection and mass analysis, and collection of particles on TEM grids for analysis, as needed. Nanoparticles are injected using an electrospray ionization (ESI) source, and conditions are described for spraying and trapping polymer particles, bare metal particles, and ligand stabilized particles with masses ranging frommore » 200 kDa to >3 GDa. Conditions appropriate to ESI and injection of different types of particles are described. The instrument is equipped with two ion guides separating the ESI source and nanoparticle trap. The first ion guide is mostly to allow desolvation and differential pumping before the particles enter the trap section of the instrument. The second is a linear quadrupole guide, which can be operated in mass selective or mass band-pass modes to limit transmission to species with mass-to-charge ratios in the range of interest. With a little experience, the design allows injection of single particles into the trap upon demand.« less

  20. Bioengineering of injectable encapsulated aggregates of pluripotent stem cells for therapy of myocardial infarction

    NASA Astrophysics Data System (ADS)

    Zhao, Shuting; Xu, Zhaobin; Wang, Hai; Reese, Benjamin E.; Gushchina, Liubov V.; Jiang, Meng; Agarwal, Pranay; Xu, Jiangsheng; Zhang, Mingjun; Shen, Rulong; Liu, Zhenguo; Weisleder, Noah; He, Xiaoming

    2016-10-01

    It is difficult to achieve minimally invasive injectable cell delivery while maintaining high cell retention and animal survival for in vivo stem cell therapy of myocardial infarction. Here we show that pluripotent stem cell aggregates pre-differentiated into the early cardiac lineage and encapsulated in a biocompatible and biodegradable micromatrix, are suitable for injectable delivery. This method significantly improves the survival of the injected cells by more than six-fold compared with the conventional practice of injecting single cells, and effectively prevents teratoma formation. Moreover, this method significantly enhances cardiac function and survival of animals after myocardial infarction, as a result of a localized immunosuppression effect of the micromatrix and the in situ cardiac regeneration by the injected cells.

Top