Wei, Zhenwei; Xiong, Xingchuang; Guo, Chengan; Si, Xingyu; Zhao, Yaoyao; He, Muyi; Yang, Chengdui; Xu, Wei; Tang, Fei; Fang, Xiang; Zhang, Sichun; Zhang, Xinrong
2015-11-17
We had developed pulsed direct current electrospray ionization mass spectrometry (pulsed-dc-ESI-MS) for systematically profiling and determining components in small volume sample. Pulsed-dc-ESI utilized constant high voltage to induce the generation of single polarity pulsed electrospray remotely. This method had significantly boosted the sample economy, so as to obtain several minutes MS signal duration from merely picoliter volume sample. The elongated MS signal duration enable us to collect abundant MS(2) information on interested components in a small volume sample for systematical analysis. This method had been successfully applied for single cell metabolomics analysis. We had obtained 2-D profile of metabolites (including exact mass and MS(2) data) from single plant and mammalian cell, concerning 1034 components and 656 components for Allium cepa and HeLa cells, respectively. Further identification had found 162 compounds and 28 different modification groups of 141 saccharides in a single Allium cepa cell, indicating pulsed-dc-ESI a powerful tool for small volume sample systematical analysis.
Bernsen, M R; Dijkman, H B; de Vries, E; Figdor, C G; Ruiter, D J; Adema, G J; van Muijen, G N
1998-10-01
Molecular analysis of small tissue samples has become increasingly important in biomedical studies. Using a laser dissection microscope and modified nucleic acid isolation protocols, we demonstrate that multiple mRNA as well as DNA sequences can be identified from a single-cell sample. In addition, we show that the specificity of procurement of tissue samples is not compromised by smear contamination resulting from scraping of the microtome knife during sectioning of lesions. The procedures described herein thus allow for efficient RT-PCR or PCR analysis of multiple nucleic acid sequences from small tissue samples obtained by laser-assisted microdissection.
Diversity of human small intestinal Streptococcus and Veillonella populations.
van den Bogert, Bartholomeus; Erkus, Oylum; Boekhorst, Jos; de Goffau, Marcus; Smid, Eddy J; Zoetendal, Erwin G; Kleerebezem, Michiel
2013-08-01
Molecular and cultivation approaches were employed to study the phylogenetic richness and temporal dynamics of Streptococcus and Veillonella populations in the small intestine. Microbial profiling of human small intestinal samples collected from four ileostomy subjects at four time points displayed abundant populations of Streptococcus spp. most affiliated with S. salivarius, S. thermophilus, and S. parasanguinis, as well as Veillonella spp. affiliated with V. atypica, V. parvula, V. dispar, and V. rogosae. Relative abundances varied per subject and time of sampling. Streptococcus and Veillonella isolates were cultured using selective media from ileostoma effluent samples collected at two time points from a single subject. The richness of the Streptococcus and Veillonella isolates was assessed at species and strain level by 16S rRNA gene sequencing and genetic fingerprinting, respectively. A total of 160 Streptococcus and 37 Veillonella isolates were obtained. Genetic fingerprinting differentiated seven Streptococcus lineages from ileostoma effluent, illustrating the strain richness within this ecosystem. The Veillonella isolates were represented by a single phylotype. Our study demonstrated that the small intestinal Streptococcus populations displayed considerable changes over time at the genetic lineage level because only representative strains of a single Streptococcus lineage could be cultivated from ileostoma effluent at both time points. © 2013 Federation of European Microbiological Societies. Published by John Wiley & Sons Ltd. All rights reserved.
Non-destructive controlled single-particle light scattering measurement
NASA Astrophysics Data System (ADS)
Maconi, G.; Penttilä, A.; Kassamakov, I.; Gritsevich, M.; Helander, P.; Puranen, T.; Salmi, A.; Hæggström, E.; Muinonen, K.
2018-01-01
We present a set of light scattering data measured from a millimeter-sized extraterrestrial rock sample. The data were acquired by our novel scatterometer, which enables accurate multi-wavelength measurements of single-particle samples whose position and orientation are controlled by ultrasonic levitation. The measurements demonstrate a non-destructive approach to derive optical properties of small mineral samples. This enables research on valuable materials, such as those returned from space missions or rare meteorites.
Axial tomography in 3D live cell microscopy
NASA Astrophysics Data System (ADS)
Richter, Verena; Bruns, Sarah; Bruns, Thomas; Piper, Mathis; Weber, Petra; Wagner, Michael; Cremer, Christoph; Schneckenburger, Herbert
2017-07-01
A miniaturized setup for sample rotation on a microscope stage has been developed, combined with light sheet, confocal or structured illumination microscopy and applied to living cells as well as to small organisms. This setup permits axial tomography with improved visualization of single cells or small cell clusters as well as an enhanced effective 3D resolution upon sample rotation.
When the Test of Mediation is More Powerful than the Test of the Total Effect
O'Rourke, Holly P.; MacKinnon, David P.
2014-01-01
Although previous research has studied power in mediation models, the extent to which the inclusion of a mediator will increase power has not been investigated. First, a study compared analytical power of the mediated effect to the total effect in a single mediator model to identify the situations in which the inclusion of one mediator increased statistical power. Results from the first study indicated that including a mediator increased statistical power in small samples with large coefficients and in large samples with small coefficients, and when coefficients were non-zero and equal across models. Next, a study identified conditions where power was greater for the test of the total mediated effect compared to the test of the total effect in the parallel two mediator model. Results indicated that including two mediators increased power in small samples with large coefficients and in large samples with small coefficients, the same pattern of results found in the first study. Finally, a study assessed analytical power for a sequential (three-path) two mediator model and compared power to detect the three-path mediated effect to power to detect both the test of the total effect and the test of the mediated effect for the single mediator model. Results indicated that the three-path mediated effect had more power than the mediated effect from the single mediator model and the test of the total effect. Practical implications of these results for researchers are then discussed. PMID:24903690
NASA Astrophysics Data System (ADS)
von Stetten, Eric Carl
The electron-positron momentum density has been measured by the two dimensional angular correlation of annihilation radiation (2D ACAR) technique for single crystal and polycrystalline (sintered powder) YBa_2 Cu_3O_{7-x} samples. For sintered superconducting and nonsuperconducting samples, the shape and temperature variation of the momentum density was investigated using the high sensitivity 2D ACAR technique. The possible existence of Fermi surfaces (FS's) in the YBa_2Cu _3O_{7-x} system was investigated in high precision 2D ACAR experiments on an oriented (twinned) single crystal superconducting YBa_2Cu _3O_{7-x} (x ~ 0.1) sample, at temperatures above and below the superconducting transition temperature (~85 K). These experiments were performed in the c-axis projection, in order to observe the theoretically predicted cylindrical FS's (if they exist) in a single experiment, without a full reconstruction of the three dimensional momentum density. Large differences were observed between the room temperature 2D ACAR spectra for superconducting and nonsuperconducting sintered powder samples, and smaller differences were observed between the spectra for similarly prepared superconducting samples. For sintered superconducting samples, complex sample dependent temperature variations of the momentum density were observed, in contrast to the small linear temperature variation observed for a sintered powder nonsuperconducting sample. These results are interpreted as manifestations of the theoretically predicted preferential sampling of the linear Cu-O chain region by the positron in the YBa _2Cu_3O _{7-x} system. High precision experiments on the single crystal superconducting sample revealed a nearly isotropic 2D ACAR spectrum, with only four small (~3% of the height at p_{x} = p _{y} = 0) peaks centered along the (110) symmetry lines. A small narrowing of the 2D ACAR spectrum was observed above T_{c}. The Brillouin-zone-reduced momentum density was formed using the "Lock-Crisp-West folding" technique, in order to identify possible FS signatures; several small features were observed that could possibly be due to FS's. A computer study of statistical noise propagation in 2D ACAR data, however, found that the possible FS signatures in the experimental data are similar in shape and magnitude to noise produced features.
Advanced Experimental Methods for Low-temperature Magnetotransport Measurement of Novel Materials
Hagmann, Joseph A.; Le, Son T.; Richter, Curt A.; Seiler, David G.
2016-01-01
Novel electronic materials are often produced for the first time by synthesis processes that yield bulk crystals (in contrast to single crystal thin film synthesis) for the purpose of exploratory materials research. Certain materials pose a challenge wherein the traditional bulk Hall bar device fabrication method is insufficient to produce a measureable device for sample transport measurement, principally because the single crystal size is too small to attach wire leads to the sample in a Hall bar configuration. This can be, for example, because the first batch of a new material synthesized yields very small single crystals or because flakes of samples of one to very few monolayers are desired. In order to enable rapid characterization of materials that may be carried out in parallel with improvements to their growth methodology, a method of device fabrication for very small samples has been devised to permit the characterization of novel materials as soon as a preliminary batch has been produced. A slight variation of this methodology is applicable to producing devices using exfoliated samples of two-dimensional materials such as graphene, hexagonal boron nitride (hBN), and transition metal dichalcogenides (TMDs), as well as multilayer heterostructures of such materials. Here we present detailed protocols for the experimental device fabrication of fragments and flakes of novel materials with micron-sized dimensions onto substrate and subsequent measurement in a commercial superconducting magnet, dry helium close-cycle cryostat magnetotransport system at temperatures down to 0.300 K and magnetic fields up to 12 T. PMID:26863449
When the test of mediation is more powerful than the test of the total effect.
O'Rourke, Holly P; MacKinnon, David P
2015-06-01
Although previous research has studied power in mediation models, the extent to which the inclusion of a mediator will increase power has not been investigated. To address this deficit, in a first study we compared the analytical power values of the mediated effect and the total effect in a single-mediator model, to identify the situations in which the inclusion of one mediator increased statistical power. The results from this first study indicated that including a mediator increased statistical power in small samples with large coefficients and in large samples with small coefficients, and when coefficients were nonzero and equal across models. Next, we identified conditions under which power was greater for the test of the total mediated effect than for the test of the total effect in the parallel two-mediator model. These results indicated that including two mediators increased power in small samples with large coefficients and in large samples with small coefficients, the same pattern of results that had been found in the first study. Finally, we assessed the analytical power for a sequential (three-path) two-mediator model and compared the power to detect the three-path mediated effect to the power to detect both the test of the total effect and the test of the mediated effect for the single-mediator model. The results indicated that the three-path mediated effect had more power than the mediated effect from the single-mediator model and the test of the total effect. Practical implications of these results for researchers are then discussed.
Fabrication of Large Domain YBa2Cu3O(x) for Magnetic Suspension Applications
NASA Technical Reports Server (NTRS)
Sengupta, S.; Corpus, J.; Gaines, J. R., Jr.; Todt, V. R.; Zhang, X.; Miller, D. J.
1996-01-01
Large domain YBa2Cu3O(x) levitators have been fabricated using a seeded melt processing technique. Depending upon the seed, either a single or five domained sample can be obtained. The grain boundaries separating each domains in the five domain levitator are found to be 90 degrees. Similar levitation forces can be observed for single and five domained samples. After thermal cycling, however, a small decrease in the levitation force of the five domain levitator was observed as a function of thermal cycles while nearly no change in force was observed in the single domain levitator. Finally, it is shown that both, single and five domain YBCO, behave similarly as a function of sample thickness.
Adamec, Jiri; Yang, Wen-Chu; Regnier, Fred E
2014-01-14
Reagents and methods are provided that permit simultaneous analysis of multiple diverse small molecule analytes present in a complex mixture. Samples are labeled with chemically identical but isotopically distince forms of the labeling reagent, and analyzed using mass spectrometry. A single reagent simultaneously derivatizes multiple small molecule analytes having different reactive functional groups.
NASA Astrophysics Data System (ADS)
Chen, Yu-Chih; Cheng, Yu-Heng; Ingram, Patrick; Yoon, Euisik
2016-06-01
Proteolytic degradation of the extracellular matrix (ECM) is critical in cancer invasion, and recent work suggests that heterogeneous cancer populations cooperate in this process. Despite the importance of cell heterogeneity, conventional proteolytic assays measure average activity, requiring thousands of cells and providing limited information about heterogeneity and dynamics. Here, we developed a microfluidic platform that provides high-efficiency cell loading and simple valveless isolation, so the proteolytic activity of a small sample (10-100 cells) can be easily characterized. Combined with a single cell derived (clonal) sphere formation platform, we have successfully demonstrated the importance of microenvironmental cues for proteolytic activity and also investigated the difference between clones. Furthermore, the platform allows monitoring single cells at multiple time points, unveiling different cancer cell line dynamics in proteolytic activity. The presented tool facilitates single cell proteolytic analysis using small samples, and our findings illuminate the heterogeneous and dynamic nature of proteolytic activity.
Optics-Integrated Microfluidic Platforms for Biomolecular Analyses
Bates, Kathleen E.; Lu, Hang
2016-01-01
Compared with conventional optical methods, optics implemented on microfluidic chips provide small, and often much cheaper ways to interrogate biological systems from the level of single molecules up to small model organisms. The optical probing of single molecules has been used to investigate the mechanical properties of individual biological molecules; however, multiplexing of these measurements through microfluidics and nanofluidics confers many analytical advantages. Optics-integrated microfluidic systems can significantly simplify sample processing and allow a more user-friendly experience; alignments of on-chip optical components are predetermined during fabrication and many purely optical techniques are passively controlled. Furthermore, sample loss from complicated preparation and fluid transfer steps can be virtually eliminated, a particularly important attribute for biological molecules at very low concentrations. Excellent fluid handling and high surface area/volume ratios also contribute to faster detection times for low abundance molecules in small sample volumes. Although integration of optical systems with classical microfluidic analysis techniques has been limited, microfluidics offers a ready platform for interrogation of biophysical properties. By exploiting the ease with which fluids and particles can be precisely and dynamically controlled in microfluidic devices, optical sensors capable of unique imaging modes, single molecule manipulation, and detection of minute changes in concentration of an analyte are possible. PMID:27119629
FT-Raman study of dehydrogenation polymer (DHP) lignins
Umesh P. Agarwal; Noritsugu Terashima
2003-01-01
Compared to conventional Raman spectroscopy where samples are excited using visible light lasers, 1064 nm-excited FT-Raman technique has the single most important advantage that the sample-fluorescence is significantly suppressed for samples that are strongly fluorescent. DHPs are difficult to analyze in conventional Raman because small amounts of chromophores present...
Ultrasonic characterization of single drops of liquids
Sinha, Dipen N.
1998-01-01
Ultrasonic characterization of single drops of liquids. The present invention includes the use of two closely spaced transducers, or one transducer and a closely spaced reflector plate, to form an interferometer suitable for ultrasonic characterization of droplet-size and smaller samples without the need for a container. The droplet is held between the interferometer elements, whose distance apart may be adjusted, by surface tension. The surfaces of the interferometer elements may be readily cleansed by a stream of solvent followed by purified air when it is desired to change samples. A single drop of liquid is sufficient for high-quality measurement. Examples of samples which may be investigated using the apparatus and method of the present invention include biological specimens (tear drops; blood and other body fluid samples; samples from tumors, tissues, and organs; secretions from tissues and organs; snake and bee venom, etc.) for diagnostic evaluation, samples in forensic investigations, and detection of drugs in small quantities.
NASA Astrophysics Data System (ADS)
Rackwitz, Sergej; Faus, Isabelle; Schmitz, Markus; Kelm, Harald; Krüger, Hans-Jörg; Andersson, K. Kristoffer; Hersleth, Hans-Petter; Achterhold, Klaus; Schlage, Kai; Wille, Hans-Christian; Schünemann, Volker; Wolny, Juliusz A.
2014-04-01
In order to carry out orientation dependent nuclear resonance scattering (NRS) experiments on small single crystals of e.g. iron proteins and/or chemical complexes but also on surfaces and other micrometer-sized samples a 2-circle goniometer including sample positioning optics has been installed at beamline P01, PETRA III, DESY, Hamburg. This sample environment is now available for all users of this beamline. Sample cooling is performed with a cryogenic gas stream which allows NRS measurements in the temperature range from 80 up to 400 K. In a first test this new sample environment has been used in order to investigate the orientation dependence of the nuclear inelastic scattering (NIS) signature of (i) a dinuclear iron(II) spin crossover (SCO) system and (ii) a hydrogen peroxide treated metmyoglobin single crystal.
NASA Astrophysics Data System (ADS)
Kalb, Wolfgang L.; Haas, Simon; Krellner, Cornelius; Mathis, Thomas; Batlogg, Bertram
2010-04-01
We show that it is possible to reach one of the ultimate goals of organic electronics: producing organic field-effect transistors with trap densities as low as in the bulk of single crystals. We studied the spectral density of localized states in the band gap [trap density of states (trap DOS)] of small-molecule organic semiconductors as derived from electrical characteristics of organic field-effect transistors or from space-charge-limited current measurements. This was done by comparing data from a large number of samples including thin-film transistors (TFT’s), single crystal field-effect transistors (SC-FET’s) and bulk samples. The compilation of all data strongly suggests that structural defects associated with grain boundaries are the main cause of “fast” hole traps in TFT’s made with vacuum-evaporated pentacene. For high-performance transistors made with small-molecule semiconductors such as rubrene it is essential to reduce the dipolar disorder caused by water adsorbed on the gate dielectric surface. In samples with very low trap densities, we sometimes observe a steep increase in the trap DOS very close (<0.15eV) to the mobility edge with a characteristic slope of 10-20 meV. It is discussed to what degree band broadening due to the thermal fluctuation of the intermolecular transfer integral is reflected in this steep increase in the trap DOS. Moreover, we show that the trap DOS in TFT’s with small-molecule semiconductors is very similar to the trap DOS in hydrogenated amorphous silicon even though polycrystalline films of small-molecules with van der Waals-type interaction on the one hand are compared with covalently bound amorphous silicon on the other hand.
Self-induced quasistationary magnetic fields.
Kamenetskii, E O
2006-01-01
The interaction of electromagnetic radiation with temporally dispersive magnetic solids of small dimensions may show very special resonant behaviors. The internal fields of such samples are characterized by magnetostatic-potential scalar wave functions. The oscillating modes have the energy orthogonality properties and unusual pseudoelectric (gauge) fields. Because of a phase factor, that makes the states single valued, a persistent magnetic current exists. This leads to appearance of an eigenelectric moment of a small disk sample. One of the intriguing features of the mode fields is dynamical symmetry breaking.
Huber, Stefan; Klein, Elise; Moeller, Korbinian; Willmes, Klaus
2015-10-01
In neuropsychological research, single-cases are often compared with a small control sample. Crawford and colleagues developed inferential methods (i.e., the modified t-test) for such a research design. In the present article, we suggest an extension of the methods of Crawford and colleagues employing linear mixed models (LMM). We first show that a t-test for the significance of a dummy coded predictor variable in a linear regression is equivalent to the modified t-test of Crawford and colleagues. As an extension to this idea, we then generalized the modified t-test to repeated measures data by using LMMs to compare the performance difference in two conditions observed in a single participant to that of a small control group. The performance of LMMs regarding Type I error rates and statistical power were tested based on Monte-Carlo simulations. We found that starting with about 15-20 participants in the control sample Type I error rates were close to the nominal Type I error rate using the Satterthwaite approximation for the degrees of freedom. Moreover, statistical power was acceptable. Therefore, we conclude that LMMs can be applied successfully to statistically evaluate performance differences between a single-case and a control sample. Copyright © 2015 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Zhou, Yuncheng; Jiang, Peng; Kuang, Jianlei; Yang, Xueshan; Cao, Wenbin
2018-07-01
The YIn1-xMnxO3 (0.1 ≤x ≤ 0.5) blue pigment samples are successfully prepared through a sol-gel process followed by microwave assisted sintering process. All the samples are shown single phases in the X-ray diffraction results. In the morphology study from scanning electronic microscope, the samples are composed of loosely connected small particles. The oxidation state of Mn is confirmed to be 3 + from the results of X-ray photonelectronic scan. The optical properties are characterized by UV-Visible spectrum and UV-visible-NIR spectrum. The samples exhibit intense blue color and they show small absorption in infrared region.
U/Th dating by SHRIMP RG ion-microprobe mass spectrometry using single ion-exchange beads
NASA Astrophysics Data System (ADS)
Bischoff, James L.; Wooden, Joe; Murphy, Fred; Williams, Ross W.
2005-04-01
We present a new analytical method for U-series isotopes using the SHRIMP RG (Sensitive High mass Resolution Ion MicroProbe) mass spectrometer that utilizes the preconcentration of the U-series isotopes from a sample onto a single ion-exchange bead. Ion-microprobe mass spectrometry is capable of producing Th ionization efficiencies in excess of 2%. Analytical precision is typically better than alpha spectroscopy, but not as good as thermal ionization mass spectroscopy (TIMS) and inductively coupled plasma multicollector mass spectrometry (ICP-MS). Like TIMS and ICP-MS the method allows analysis of small samples sizes, but also adds the advantage of rapidity of analysis. A major advantage of ion-microprobe analysis is that U and Th isotopes are analyzed in the same bead, simplifying the process of chemical separation. Analytical time on the instrument is ˜60 min per sample, and a single instrument-loading can accommodate 15-20 samples to be analyzed in a 24-h day. An additional advantage is that the method allows multiple reanalyses of the same bead and that samples can be archived for reanalysis at a later time. Because the ion beam excavates a pit only a few μm deep, the mount can later be repolished and reanalyzed numerous times. The method described of preconcentrating a low concentration sample onto a small conductive substrate to allow ion-microprobe mass spectrometry is potentially applicable to many other systems.
U/Th dating by SHRIMP RG ion-microprobe mass spectrometry using single ion-exchange beads
Bischoff, J.L.; Wooden, J.; Murphy, F.; Williams, Ross W.
2005-01-01
We present a new analytical method for U-series isotopes using the SHRIMP RG (Sensitive High mass Resolution Ion MicroProbe) mass spectrometer that utilizes the preconcentration of the U-series isotopes from a sample onto a single ion-exchange bead. Ion-microprobe mass spectrometry is capable of producing Th ionization efficiencies in excess of 2%. Analytical precision is typically better than alpha spectroscopy, but not as good as thermal ionization mass spectroscopy (TIMS) and inductively coupled plasma multicollector mass spectrometry (ICP-MS). Like TIMS and ICP-MS the method allows analysis of small samples sizes, but also adds the advantage of rapidity of analysis. A major advantage of ion-microprobe analysis is that U and Th isotopes are analyzed in the same bead, simplifying the process of chemical separation. Analytical time on the instrument is ???60 min per sample, and a single instrument-loading can accommodate 15-20 samples to be analyzed in a 24-h day. An additional advantage is that the method allows multiple reanalyses of the same bead and that samples can be archived for reanalysis at a later time. Because the ion beam excavates a pit only a few ??m deep, the mount can later be repolished and reanalyzed numerous times. The method described of preconcentrating a low concentration sample onto a small conductive substrate to allow ion-microprobe mass spectrometry is potentially applicable to many other systems. Copyright ?? 2005 Elsevier Ltd.
Ultrasonic characterization of single drops of liquids
Sinha, D.N.
1998-04-14
Ultrasonic characterization of single drops of liquids is disclosed. The present invention includes the use of two closely spaced transducers, or one transducer and a closely spaced reflector plate, to form an interferometer suitable for ultrasonic characterization of droplet-size and smaller samples without the need for a container. The droplet is held between the interferometer elements, whose distance apart may be adjusted, by surface tension. The surfaces of the interferometer elements may be readily cleansed by a stream of solvent followed by purified air when it is desired to change samples. A single drop of liquid is sufficient for high-quality measurement. Examples of samples which may be investigated using the apparatus and method of the present invention include biological specimens (tear drops; blood and other body fluid samples; samples from tumors, tissues, and organs; secretions from tissues and organs; snake and bee venom, etc.) for diagnostic evaluation, samples in forensic investigations, and detection of drugs in small quantities. 5 figs.
Ultrasonic characterization of single drops of liquids
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sinha, D.N.
Ultrasonic characterization of single drops of liquids is disclosed. The present invention includes the use of two closely spaced transducers, or one transducer and a closely spaced reflector plate, to form an interferometer suitable for ultrasonic characterization of droplet-size and smaller samples without the need for a container. The droplet is held between the interferometer elements, whose distance apart may be adjusted, by surface tension. The surfaces of the interferometer elements may be readily cleansed by a stream of solvent followed by purified air when it is desired to change samples. A single drop of liquid is sufficient for high-qualitymore » measurement. Examples of samples which may be investigated using the apparatus and method of the present invention include biological specimens (tear drops; blood and other body fluid samples; samples from tumors, tissues, and organs; secretions from tissues and organs; snake and bee venom, etc.) for diagnostic evaluation, samples in forensic investigations, and detection of drugs in small quantities. 5 figs.« less
Nikfarjam, Miead; López-Guerra, Enrique A; Solares, Santiago D; Eslami, Babak
2018-01-01
In this short paper we explore the use of higher eigenmodes in single-eigenmode amplitude-modulation atomic force microscopy (AFM) for the small-indentation imaging of soft viscoelastic materials. In viscoelastic materials, whose response depends on the deformation rate, the tip-sample forces generated as a result of sample deformation increase as the tip velocity increases. Since the eigenfrequencies in a cantilever increase with eigenmode order, and since higher oscillation frequencies lead to higher tip velocities for a given amplitude (in viscoelastic materials), the sample indentation can in some cases be reduced by using higher eigenmodes of the cantilever. This effect competes with the lower sensitivity of higher eigenmodes, due to their larger force constant, which for elastic materials leads to greater indentation for similar amplitudes, compared with lower eigenmodes. We offer a short theoretical discussion of the key underlying concepts, along with numerical simulations and experiments to illustrate a simple recipe for imaging soft viscoelastic matter with reduced indentation.
Morphological classification of bioaerosols from composting using scanning electron microscopy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tamer Vestlund, A.; FIRA International Ltd., Maxwell Road, Stevenage, Herts SG1 2EW; Al-Ashaab, R.
2014-07-15
Highlights: • Bioaerosols were captured using the filter method. • Bioaerosols were analysed using scanning electron microscope. • Bioaerosols were classified on the basis of morphology. • Single small cells were found more frequently than aggregates and larger cells. • Smaller cells may disperse further than heavier aggregate structures. - Abstract: This research classifies the physical morphology (form and structure) of bioaerosols emitted from open windrow composting. Aggregation state, shape and size of the particles captured are reported alongside the implications for bioaerosol dispersal after release. Bioaerosol sampling took place at a composting facility using personal air filter samplers. Samplesmore » were analysed using scanning electron microscopy. Particles were released mainly as small (<1 μm) single, spherical cells, followed by larger (>1 μm) single cells, with aggregates occurring in smaller proportions. Most aggregates consisted of clusters of 2–3 particles as opposed to chains, and were <10 μm in size. No cells were attached to soil debris or wood particles. These small single cells or small aggregates are more likely to disperse further downwind from source, and cell viability may be reduced due to increased exposure to environmental factors.« less
A Novel Videography Method for Generating Crack-Extension Resistance Curves in Small Bone Samples
Katsamenis, Orestis L.; Jenkins, Thomas; Quinci, Federico; Michopoulou, Sofia; Sinclair, Ian; Thurner, Philipp J.
2013-01-01
Assessment of bone quality is an emerging solution for quantifying the effects of bone pathology or treatment. Perhaps one of the most important parameters characterising bone quality is the toughness behaviour of bone. Particularly, fracture toughness, is becoming a popular means for evaluating bone quality. The method is moving from a single value approach that models bone as a linear-elastic material (using the stress intensity factor, K) towards full crack extension resistance curves (R-curves) using a non-linear model (the strain energy release rate in J-R curves). However, for explanted human bone or small animal bones, there are difficulties in measuring crack-extension resistance curves due to size constraints at the millimetre and sub-millimetre scale. This research proposes a novel “whitening front tracking” method that uses videography to generate full fracture resistance curves in small bone samples where crack propagation cannot typically be observed. Here we present this method on sharp edge notched samples (<1 mm×1 mm×Length) prepared from four human femora tested in three-point bending. Each sample was loaded in a mechanical tester with the crack propagation recorded using videography and analysed using an algorithm to track the whitening (damage) zone. Using the “whitening front tracking” method, full R-curves and J-R curves could be generated for these samples. The curves for this antiplane longitudinal orientation were similar to those found in the literature, being between the published longitudinal and transverse orientations. The proposed technique shows the ability to generate full “crack” extension resistance curves by tracking the whitening front propagation to overcome the small size limitations and the single value approach. PMID:23405186
ERIC Educational Resources Information Center
Maggin, Daniel M.; Swaminathan, Hariharan; Rogers, Helen J.; O'Keeffe, Breda V.; Sugai, George; Horner, Robert H.
2011-01-01
A new method for deriving effect sizes from single-case designs is proposed. The strategy is applicable to small-sample time-series data with autoregressive errors. The method uses Generalized Least Squares (GLS) to model the autocorrelation of the data and estimate regression parameters to produce an effect size that represents the magnitude of…
Palousek, David; Pantelejev, Libor; Hoeller, Christian; Pichler, Rudolf; Tesicky, Lukas; Kaiser, Jozef
2018-01-01
This paper deals with various selective laser melting (SLM) processing strategies for aluminum 2618 powder in order to get material densities and properties close to conventionally-produced, high-strength 2618 alloy. To evaluate the influence of laser scanning strategies on the resulting porosity and mechanical properties a row of experiments was done. Three types of samples were used: single-track welds, bulk samples and samples for tensile testing. Single-track welds were used to find the appropriate processing parameters for achieving continuous and well-shaped welds. The bulk samples were built with different scanning strategies with the aim of reaching a low relative porosity of the material. The combination of the chessboard strategy with a 2 × 2 mm field size fabricated with an out-in spiral order was found to eliminate a major lack of fusion defects. However, small cracks in the material structure were found over the complete range of tested parameters. The decisive criteria was the elimination of small cracks that drastically reduced mechanical properties. Reduction of the thermal gradient using support structures or fabrication under elevated temperatures shows a promising approach to eliminating the cracks. Mechanical properties of samples produced by SLM were compared with the properties of extruded material. The results showed that the SLM-processed 2618 alloy could only reach one half of the yield strength and tensile strength of extruded material. This is mainly due to the occurrence of small cracks in the structure of the built material. PMID:29443912
Mixed Estimation for a Forest Survey Sample Design
Francis A. Roesch
1999-01-01
Three methods of estimating the current state of forest attributes over small areas for the USDA Forest Service Southern Research Station's annual forest sampling design are compared. The three methods were (I) simple moving average, (II) single imputation of plot data that had been updated by externally developed models, and (III) local application of a global...
Si:Bi switched photoconducttor infrared detector array
NASA Technical Reports Server (NTRS)
Eakin, C. E.
1983-01-01
A multiplexed infrared detector array is described. The small demonstration prototype consisted of two cryogenically cooled, bismuth doped silicon, extrinsic photoconductor pixels multiplexed onto a single output channel using an on focal plane switch integration sampling technique. Noise levels of the order of 400 to 600 rms electrons per sample were demonstrated for this chip and wire hybrid version.
Millimeter Wave Sensor For On-Line Inspection Of Thin Sheet Dielectrics
Bakhtiari, Sasan; Gopalsami, Nachappa; Raptis, Apostolos C.
1999-03-23
A millimeter wave sensor is provided for non-destructive inspection of thin sheet dielectric materials. The millimeter wave sensor includes a Gunn diode oscillator (GDO) source generating a mill meter wave electromagnetic energy signal having a single frequency. A heater is coupled to the GDO source for stabilizing the single frequency. A small size antenna is coupled to the GDO source for transmitting the millimeter wave electromagnetic energy signal to a sample material and for receiving a reflected millimeter wave electromagnetic energy signal from the sample material. Ferrite circulator isolators coupled between the GDO source and the antenna separate the millimeter wave electromagnetic energy signal into transmitted and received electromagnetic energy signal components and a detector detects change in both amplitude and phase of the transmitted and received electromagnetic energy signal components. A millimeter wave sensor is provided for non-destructive inspection of thin sheet dielectric materials. The millimeter wave sensor includes a Gunn diode oscillator (GDO) source generating a mill meter wave electromagnetic energy signal having a single frequency. A heater is coupled to the GDO source for stabilizing the single frequency. A small size antenna is coupled to the GDO source for transmitting the millimeter wave electromagnetic energy signal to a sample material and for receiving a reflected millimeter wave electromagnetic energy signal from the sample material. Ferrite circulator isolators coupled between the GDO source and the antenna separate the millimeter wave electromagnetic energy signal into transmitted and received electromagnetic energy signal components and a detector detects change in both amplitude and phase of the transmitted and received electromagnetic energy signal components.
NASA Astrophysics Data System (ADS)
Christopher, Benedict; Rao, Ashok; Deka, Utpal; Prasad K, Shyam; Okram, G. S.; Sanjeev, Ganesh; Chandra Petwal, Vikash; Verma, Vijay Pal; Dwivedi, Jishnu
2018-07-01
The study of electronic and magnetic properties of electron beam (EB) irradiated PrCoO3 manganites is presented in this communication. The diffraction data confirms that pristine as well as electron beam irradiated samples are single phased and they crystalize at orthorhombic distorted structure with Pbnm space group. The electrical resistivity of all the samples reveals semiconducting behavior. Small polaron hopping model is appropriately employed to investigate the semiconducting nature of the pristine and EB irradiated samples. The Seebeck coefficient (S) data of the pristine sample exhibits colossally high positive value (about 300 mV/K) and substantial decrease in S value is noticed in the irradiated samples. The high temperature analysis of thermopower data validates the small polaron hopping model. The magnetic measurements display possible existence of super-paramagnetic characteristics in the samples.
High-efficiency multiphoton boson sampling
NASA Astrophysics Data System (ADS)
Wang, Hui; He, Yu; Li, Yu-Huai; Su, Zu-En; Li, Bo; Huang, He-Liang; Ding, Xing; Chen, Ming-Cheng; Liu, Chang; Qin, Jian; Li, Jin-Peng; He, Yu-Ming; Schneider, Christian; Kamp, Martin; Peng, Cheng-Zhi; Höfling, Sven; Lu, Chao-Yang; Pan, Jian-Wei
2017-06-01
Boson sampling is considered as a strong candidate to demonstrate 'quantum computational supremacy' over classical computers. However, previous proof-of-principle experiments suffered from small photon number and low sampling rates owing to the inefficiencies of the single-photon sources and multiport optical interferometers. Here, we develop two central components for high-performance boson sampling: robust multiphoton interferometers with 99% transmission rate and actively demultiplexed single-photon sources based on a quantum dot-micropillar with simultaneously high efficiency, purity and indistinguishability. We implement and validate three-, four- and five-photon boson sampling, and achieve sampling rates of 4.96 kHz, 151 Hz and 4 Hz, respectively, which are over 24,000 times faster than previous experiments. Our architecture can be scaled up for a larger number of photons and with higher sampling rates to compete with classical computers, and might provide experimental evidence against the extended Church-Turing thesis.
Self-digitization microfluidic chip for absolute quantification of mRNA in single cells.
Thompson, Alison M; Gansen, Alexander; Paguirigan, Amy L; Kreutz, Jason E; Radich, Jerald P; Chiu, Daniel T
2014-12-16
Quantification of mRNA in single cells provides direct insight into how intercellular heterogeneity plays a role in disease progression and outcomes. Quantitative polymerase chain reaction (qPCR), the current gold standard for evaluating gene expression, is insufficient for providing absolute measurement of single-cell mRNA transcript abundance. Challenges include difficulties in handling small sample volumes and the high variability in measurements. Microfluidic digital PCR provides far better sensitivity for minute quantities of genetic material, but the typical format of this assay does not allow for counting of the absolute number of mRNA transcripts samples taken from single cells. Furthermore, a large fraction of the sample is often lost during sample handling in microfluidic digital PCR. Here, we report the absolute quantification of single-cell mRNA transcripts by digital, one-step reverse transcription PCR in a simple microfluidic array device called the self-digitization (SD) chip. By performing the reverse transcription step in digitized volumes, we find that the assay exhibits a linear signal across a wide range of total RNA concentrations and agrees well with standard curve qPCR. The SD chip is found to digitize a high percentage (86.7%) of the sample for single-cell experiments. Moreover, quantification of transferrin receptor mRNA in single cells agrees well with single-molecule fluorescence in situ hybridization experiments. The SD platform for absolute quantification of single-cell mRNA can be optimized for other genes and may be useful as an independent control method for the validation of mRNA quantification techniques.
Uludağ, Yildiz; Piletsky, Sergey A; Turner, Anthony P F; Cooper, Matthew A
2007-11-01
Biomimetic recognition elements employed for the detection of analytes are commonly based on proteinaceous affibodies, immunoglobulins, single-chain and single-domain antibody fragments or aptamers. The alternative supra-molecular approach using a molecularly imprinted polymer now has proven utility in numerous applications ranging from liquid chromatography to bioassays. Despite inherent advantages compared with biochemical/biological recognition (which include robustness, storage endurance and lower costs) there are few contributions that describe quantitative analytical applications of molecularly imprinted polymers for relevant small molecular mass compounds in real-world samples. There is, however, significant literature describing the use of low-power, portable piezoelectric transducers to detect analytes in environmental monitoring and other application areas. Here we review the combination of molecularly imprinted polymers as recognition elements with piezoelectric biosensors for quantitative detection of small molecules. Analytes are classified by type and sample matrix presentation and various molecularly imprinted polymer synthetic fabrication strategies are also reviewed.
Cartwright, J A; Hill, T L; Smith, S; Shaw, D
2016-07-01
Sample quality of gastrointestinal endoscopic biopsies is of paramount importance for accurate histological diagnosis. Many veterinary practices use reusable forceps as a result of perceived decreased cost. With reusable forceps, it remains unknown whether sample quality declines with repeated use and becomes inferior to single-use forceps and is therefore more or less cost effective than single-use forceps. The study hypothesis was that reusable forceps sample quality would deteriorate after repeated use as compared to single-use forceps. Sixty-five dogs undergoing gastrointestinal endoscopy for diagnostic investigations at the Hospital for Small Animals, Edinburgh University. A prospective, pathologist-blinded study comparing single-use and reusable alligator standard cup biopsy forceps (Olympus 2.0 mm 1550 mm) with 5 randomized reusable forceps. Sample quality (stomach, duodenum, ileum, and colon) was assessed by a single pathologist using the WSAVA guidelines. There was no difference in the adequacy, depth, villi number, or crush artifact in the 4 intestinal areas between forceps type with at least 10, and up to 15, repeated uses of the reusable forceps. This study demonstrates that reusable cup biopsy forceps provide equivalent biopsy quality after repeated uses to single-use forceps and are cost effective at 10-case use. Copyright © 2016 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.
Stolee, Jessica A; Vertes, Akos
2013-04-02
Ambient ionization methods for mass spectrometry have enabled the in situ and in vivo analysis of biological tissues and cells. When an etched optical fiber is used to deliver laser energy to a sample in laser ablation electrospray ionization (LAESI) mass spectrometry, the analysis of large single cells becomes possible. However, because in this arrangement the ablation plume expands in three dimensions, only a small portion of it is ionized by the electrospray. Here we show that sample ablation within a capillary helps to confine the radial expansion of the plume. Plume collimation, due to the altered expansion dynamics, leads to greater interaction with the electrospray plume resulting in increased ionization efficiency, reduced limit of detection (by a factor of ~13, reaching 600 amol for verapamil), and extended dynamic range (6 orders of magnitude) compared to conventional LAESI. This enhanced sensitivity enables the analysis of a range of metabolites from small cell populations and single cells in the ambient environment. This technique has the potential to be integrated with flow cytometry for high-throughput metabolite analysis of sorted cells.
Analytical Chemistry in Microenvironments: Single Nerve Cells.
1992-03-16
length of the capillary (34). Electroosmotic flow offers three key advantages for separation of small biological samples. First, this flow, if not...from microenvironments (ie. single cells). Indeed, volumes as low as 270 femtoliters have been injected using electroosmotic flow (15). Finally... electroosmotic flow provides a flat flow profile, since there is no stationary support between the origin of flow (capillary wall) and the bulk of solution
A Small and Slim Coaxial Probe for Single Rice Grain Moisture Sensing
You, Kok Yeow; Mun, Hou Kit; You, Li Ling; Salleh, Jamaliah; Abbas, Zulkifly
2013-01-01
A moisture detection of single rice grains using a slim and small open-ended coaxial probe is presented. The coaxial probe is suitable for the nondestructive measurement of moisture values in the rice grains ranging from from 9.5% to 26%. Empirical polynomial models are developed to predict the gravimetric moisture content of rice based on measured reflection coefficients using a vector network analyzer. The relationship between the reflection coefficient and relative permittivity were also created using a regression method and expressed in a polynomial model, whose model coefficients were obtained by fitting the data from Finite Element-based simulation. Besides, the designed single rice grain sample holder and experimental set-up were shown. The measurement of single rice grains in this study is more precise compared to the measurement in conventional bulk rice grains, as the random air gap present in the bulk rice grains is excluded. PMID:23493127
Very Low Abundance Single-Cell Transcript Quantification with 5-Plex ddPCRTM Assays.
Karlin-Neumann, George; Zhang, Bin; Litterst, Claudia
2018-01-01
Gene expression studies have provided one of the most accessible windows for understanding the molecular basis of cell and tissue phenotypes and how these change in response to stimuli. Current PCR-based and next generation sequencing methods offer great versatility in allowing the focused study of the roles of small numbers of genes or comprehensive profiling of the entire transcriptome of a sample at one time. Marrying of these approaches to various cell sorting technologies has recently enabled the profiling of expression in single cells, thereby increasing the resolution and sensitivity and strengthening the inferences from observed expression levels and changes. This chapter presents a quick and efficient 1-day workflow for sorting single cells with a small laboratory cell-sorter followed by an ultrahigh sensitivity, multiplexed digital PCR method for quantitative tracking of changes in 5-10 genes per single cell.
1981-05-01
crystals Cesium cadmium fluoride Ultrasonic wave propagation Potassium zinc fluoride Nonlinear acoustics 20. A’?S1 RACT (Continue on reverse side If...is the stray capacitance of the detector, L is the inductance of the wire leading from the banana jack to the BNC connector (shown in Figure 111-2). Z...The samples on which measurements were made included [lO0] and [1111 copper samples, a sample of potassium zinc fluoride (KZnF 3 ) and a sample of
Cavity ring-down spectroscopy in the liquid phase
NASA Astrophysics Data System (ADS)
Xu, Shucheng; Sha, Guohe; Xie, Jinchun
2002-02-01
A new application for cavity ring-down spectroscopic (CRDS) technique using a pulsed polarized light source has been developed in the absorption measurement of liquids for "colorless" organic compounds using both a single sample cell and double sample cells inserted in an optical cavity at Brewster angle. At present an experimental capability of measuring absorption coefficients as small as 2-5×10-7 cm-1 has been demonstrated by measurement of the absorption baselines. The first spectra for CRDS in the liquid phase, the C-H stretching fifth vibrational overtones of benzene in the pure liquid and hexane solution are obtained. The optical absorption length for liquids in both a single sample cell and double sample cells of 1 cm length is up to 900 cm due to multipass of light within an optical cavity. Compared to the thermal lens and optoacoustic spectroscopic techniques, the sensitivity for CRDS mainly depends on the optical absorption path of the sample (single passing path of the sample times multipass times), is not determined by the laser power and the length of the sample cell. The absolute absorption coefficient and band intensity for the sample are determined directly by the spectroscopy.
NASA Astrophysics Data System (ADS)
Li, Xiaodan; Huang, Shuangjun; Xu, Liang; Hui, Li; Zhou, Song
2017-12-01
The bolt structural properties of selective laser melted (SLM) samples produced from TC4 powder metal has been investigated. Two different connection molds relative to single lap joint and bilateral lap joint as well as two different state of surface quality were considered. Samples and test procedures were designed in accordance with HB 5143 and HB 5287 standard. The results show that there is a strong influence of connection molds on the dynamic behavior of SLM produced TC4. The mechanical properties of bilateral lap joint are better than those of the single lap joint. Meanwhile the fatigue performance of the bilateral lap joint is much stronger than that of the single lap joint which it is a symmetrical structure of the two-shear test on both sides of the force evenly, while the single lap joint is a single shear sample of the uneven force. There are two kinds of fracture form most of which are broken in the first row of screw and a small part in the middle of the connecting plate.
SMALL ANGLE SCATTERING OF X-RAYS BY PLASTICALLY DEFORMED SINGLE CRYSTALS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Robinson, W.H.; Smoluchowski, R.
1959-05-01
The small-angle scattering of x rays from single crystals of magnesium plastically deformed by simple shear was measured in the angular range of 4' to 5 deg . The crystals were subjected to both unidirectional and cyclic shear stresses applied along the STAl 1 2-bar 0! direction. Thin slices of the deformed single crystals were prepared using strainfree cutting and polishing techniques. The thin slices had orientations such that the slip direction was either parallel or perpendicular to the incident x-ray beam in order to observe any anisotropy in the scattering that might be due to dislocations. It was foundmore » that those samples which contained deformation twins within the irradiated volume produced rather large scattered intensity. This scattered intensity is interpreted as being due to double Bragg scattering. The scattered intensity from other specimens was attributed to surface scattering. No evidence for small angle scattering by dislocations was found. (auth)« less
Xu, Jiao; Li, Mei; Shi, Guoliang; Wang, Haiting; Ma, Xian; Wu, Jianhui; Shi, Xurong; Feng, Yinchang
2017-11-15
In this study, single particle mass spectra signatures of both coal burning boiler and biomass burning boiler emitted particles were studied. Particle samples were suspended in clean Resuspension Chamber, and analyzed by ELPI and SPAMS simultaneously. The size distribution of BBB (biomass burning boiler sample) and CBB (coal burning boiler sample) are different, as BBB peaks at smaller size, and CBB peaks at larger size. Mass spectra signatures of two samples were studied by analyzing the average mass spectrum of each particle cluster extracted by ART-2a in different size ranges. In conclusion, BBB sample mostly consists of OC and EC containing particles, and a small fraction of K-rich particles in the size range of 0.2-0.5μm. In 0.5-1.0μm, BBB sample consists of EC, OC, K-rich and Al_Silicate containing particles; CBB sample consists of EC, ECOC containing particles, while Al_Silicate (including Al_Ca_Ti_Silicate, Al_Ti_Silicate, Al_Silicate) containing particles got higher fractions as size increase. The similarity of single particle mass spectrum signatures between two samples were studied by analyzing the dot product, results indicated that part of the single particle mass spectra of two samples in the same size range are similar, which bring challenge to the future source apportionment activity by using single particle aerosol mass spectrometer. Results of this study will provide physicochemical information of important sources which contribute to particle pollution, and will support source apportionment activities. Copyright © 2017. Published by Elsevier B.V.
Character of the opposition effect and negative polarization
NASA Technical Reports Server (NTRS)
Pieters, Carle M.; Shkuratov, Yu. G.; Stankevich, D. G.
1991-01-01
Photometric and polarimetric properties at small phase angles were measured for silicates with controlled surface properties in order to distinguish properties that are associated with surface reflection from those that are associated with multiple scattering from internal grain boundaries. These data provide insight into the causes and conditions of photometric properties observed at small phase angles for dark bodies of the solar system. Obsidian was chosen to represent a silicate dielectric with no internal scattering boundaries. Because obsidian is free of internal scatterers, light reflected from both the rough and smooth obsidian samples is almost entirely single and multiple Fresnel reflections form surface facets with no body component. Surface structure alone cannot produce an opposition effect. Comparison of the obsidian and basalt results indicates that for an opposition effect to occur, surface texture must be both rough and contain internal scattering interfaces. Although the negative polarization observed for the obsidian samples indicates single and multiple reflections are part of negative polarization, the longer inversion angle of the multigrain inversion samples implies that internal reflections must also contribute a significant negative polarization component.
High-resolution magnetic resonance spectroscopy using a solid-state spin sensor
NASA Astrophysics Data System (ADS)
Glenn, David R.; Bucher, Dominik B.; Lee, Junghyun; Lukin, Mikhail D.; Park, Hongkun; Walsworth, Ronald L.
2018-03-01
Quantum systems that consist of solid-state electronic spins can be sensitive detectors of nuclear magnetic resonance (NMR) signals, particularly from very small samples. For example, nitrogen–vacancy centres in diamond have been used to record NMR signals from nanometre-scale samples, with sensitivity sufficient to detect the magnetic field produced by a single protein. However, the best reported spectral resolution for NMR of molecules using nitrogen–vacancy centres is about 100 hertz. This is insufficient to resolve the key spectral identifiers of molecular structure that are critical to NMR applications in chemistry, structural biology and materials research, such as scalar couplings (which require a resolution of less than ten hertz) and small chemical shifts (which require a resolution of around one part per million of the nuclear Larmor frequency). Conventional, inductively detected NMR can provide the necessary high spectral resolution, but its limited sensitivity typically requires millimetre-scale samples, precluding applications that involve smaller samples, such as picolitre-volume chemical analysis or correlated optical and NMR microscopy. Here we demonstrate a measurement technique that uses a solid-state spin sensor (a magnetometer) consisting of an ensemble of nitrogen–vacancy centres in combination with a narrowband synchronized readout protocol to obtain NMR spectral resolution of about one hertz. We use this technique to observe NMR scalar couplings in a micrometre-scale sample volume of approximately ten picolitres. We also use the ensemble of nitrogen–vacancy centres to apply NMR to thermally polarized nuclear spins and resolve chemical-shift spectra from small molecules. Our technique enables analytical NMR spectroscopy at the scale of single cells.
Zangar, Richard C.; Varnum, Susan M.; Covington, Chandice Y.; ...
2004-01-01
Identifying useful markers of cancer can be problematic due to limited amounts of sample. Some samples such as nipple aspirate fluid (NAF) or early-stage tumors are inherently small. Other samples such as serum are collected in larger volumes but archives of these samples are very valuable and only small amounts of each sample may be available for a single study. Also, given the diverse nature of cancer and the inherent variability in individual protein levels, it seems likely that the best approach to screen for cancer will be to determine the profile of a battery of proteins. As a result,more » a major challenge in identifying protein markers of disease is the ability to screen many proteins using very small amounts of sample. In this review, we outline some technological advances in proteomics that greatly advance this capability. Specifically, we propose a strategy for identifying markers of breast cancer in NAF that utilizes mass spectrometry (MS) to simultaneously screen hundreds or thousands of proteins in each sample. The best potential markers identified by the MS analysis can then be extensively characterized using an ELISA microarray assay. Because the microarray analysis is quantitative and large numbers of samples can be efficiently analyzed, this approach offers the ability to rapidly assess a battery of selected proteins in a manner that is directly relevant to traditional clinical assays.« less
Zhu, Hongying; Zou, Guichang; Wang, Ning; Zhuang, Meihui; Xiong, Wei; Huang, Guangming
2017-03-07
The use of single-cell assays has emerged as a cutting-edge technique during the past decade. Although single-cell mass spectrometry (MS) has recently achieved remarkable results, deep biological insights have not yet been obtained, probably because of various technical issues, including the unavoidable use of matrices, the inability to maintain cell viability, low throughput because of sample pretreatment, and the lack of recordings of cell physiological activities from the same cell. In this study, we describe a patch clamp/MS-based platform that enables the sensitive, rapid, and in situ chemical profiling of single living neurons. This approach integrates modified patch clamp technique and modified MS measurements to directly collect and detect nanoliter-scale samples from the cytoplasm of single neurons in mice brain slices. Abundant possible cytoplasmic constituents were detected in a single neuron at a relatively fast rate, and over 50 metabolites were identified in this study. The advantages of direct, rapid, and in situ sampling and analysis enabled us to measure the biological activities of the cytoplasmic constituents in a single neuron, including comparing neuron types by cytoplasmic chemical constituents; observing changes in constituent concentrations as the physiological conditions, such as age, vary; and identifying the metabolic pathways of small molecules.
Zhu, Hongying; Zou, Guichang; Wang, Ning; Zhuang, Meihui; Xiong, Wei; Huang, Guangming
2017-01-01
The use of single-cell assays has emerged as a cutting-edge technique during the past decade. Although single-cell mass spectrometry (MS) has recently achieved remarkable results, deep biological insights have not yet been obtained, probably because of various technical issues, including the unavoidable use of matrices, the inability to maintain cell viability, low throughput because of sample pretreatment, and the lack of recordings of cell physiological activities from the same cell. In this study, we describe a patch clamp/MS-based platform that enables the sensitive, rapid, and in situ chemical profiling of single living neurons. This approach integrates modified patch clamp technique and modified MS measurements to directly collect and detect nanoliter-scale samples from the cytoplasm of single neurons in mice brain slices. Abundant possible cytoplasmic constituents were detected in a single neuron at a relatively fast rate, and over 50 metabolites were identified in this study. The advantages of direct, rapid, and in situ sampling and analysis enabled us to measure the biological activities of the cytoplasmic constituents in a single neuron, including comparing neuron types by cytoplasmic chemical constituents; observing changes in constituent concentrations as the physiological conditions, such as age, vary; and identifying the metabolic pathways of small molecules. PMID:28223513
Nanobarcoding for improved nanoparticle detection in nanomedical biodistribution studies
NASA Astrophysics Data System (ADS)
Eustaquio, Trisha
Determination of the fate of nanoparticles (NPs) in a biological system, or NP biodistribution, is critical in evaluating a NP formulation for nanomedicine. Unlike small-molecule drugs, NPs impose unique challenges in the design of appropriate biodistribution studies due to their small size and subsequent detection signal. Current methods to determine NP biodistribution are greatly inadequate due to their limited detection thresholds. There is an overwhelming need for a sensitive and efficient imaging-based method that can (1) detect and measure small numbers of NPs of various types, ideally single NPs, (2) associate preferential NP uptake with histological cell type by preserving spatial information in samples, and (3) allow for relatively quick and accurate NP detection in in vitro (and possibly ex vivo) samples for comprehensive NP biodistribution studies. Herein, a novel method for improved NP detection is proposed, coined "nanobarcoding." Nanobarcoding utilizes a non-endogenous oligonucleotide, or "nanobarcode" (NB), conjugated to the NP surface to amplify the detection signal from a single NP via in situ polymerase chain reaction (ISPCR), and this signal amplification will facilitate rapid and precise detection of single NPs inside cells over large areas of sample such that more sophisticated studies can be performed on the NP-positive subpopulation. Moreover, nanobarcoding has the potential to be applied to the detection of more than one NP type to study the effects of physicochemical properties, targeting mechanisms, and route of entry on NP biodistribution. The nanobarcoding method was validated in vitro using NB-functionalized superparamagnetic iron oxide NPs (NB-SPIONs) as the model NP type for improved NP detection inside HeLa human cervical cancer cells, a cell line commonly used for ISPCR-mediated detection of human papilloma virus (HPV). Nanotoxicity effects of NB-SPIONs were also evaluated at the single-cell level using LEAP (Laser-Enabled Analysis and Processing, Intrexon, San Diego, CA), and NB-SPIONs were found to be less toxic than its precursor, carboxylated SPIONs (COOH-SPIONs).
NASA Technical Reports Server (NTRS)
Sielken, R. L., Jr. (Principal Investigator)
1981-01-01
Several methods of estimating individual crop acreages using a mixture of completely identified and partially identified (generic) segments from a single growing year are derived and discussed. A small Monte Carlo study of eight estimators is presented. The relative empirical behavior of these estimators is discussed as are the effects of segment sample size and amount of partial identification. The principle recommendations are (1) to not exclude, but rather incorporate partially identified sample segments into the estimation procedure, (2) try to avoid having a large percentage (say 80%) of only partially identified segments, in the sample, and (3) use the maximum likelihood estimator although the weighted least squares estimator and least squares ratio estimator both perform almost as well. Sets of spring small grains (North Dakota) data were used.
A novel approach for small sample size family-based association studies: sequential tests.
Ilk, Ozlem; Rajabli, Farid; Dungul, Dilay Ciglidag; Ozdag, Hilal; Ilk, Hakki Gokhan
2011-08-01
In this paper, we propose a sequential probability ratio test (SPRT) to overcome the problem of limited samples in studies related to complex genetic diseases. The results of this novel approach are compared with the ones obtained from the traditional transmission disequilibrium test (TDT) on simulated data. Although TDT classifies single-nucleotide polymorphisms (SNPs) to only two groups (SNPs associated with the disease and the others), SPRT has the flexibility of assigning SNPs to a third group, that is, those for which we do not have enough evidence and should keep sampling. It is shown that SPRT results in smaller ratios of false positives and negatives, as well as better accuracy and sensitivity values for classifying SNPs when compared with TDT. By using SPRT, data with small sample size become usable for an accurate association analysis.
Improved camera for better X-ray powder photographs
NASA Technical Reports Server (NTRS)
Parrish, W.; Vajda, I. E.
1969-01-01
Camera obtains powder-type photographs of single crystals or polycrystalline powder specimens. X-ray diffraction photographs of a powder specimen are characterized by improved resolution and greater intensity. A reasonably good powder pattern of small samples can be produced for identification purposes.
Simultaneous Multiparameter Cellular Energy Metabolism Profiling of Small Populations of Cells.
Kelbauskas, Laimonas; Ashili, Shashaanka P; Lee, Kristen B; Zhu, Haixin; Tian, Yanqing; Meldrum, Deirdre R
2018-03-12
Functional and genomic heterogeneity of individual cells are central players in a broad spectrum of normal and disease states. Our knowledge about the role of cellular heterogeneity in tissue and organism function remains limited due to analytical challenges one encounters when performing single cell studies in the context of cell-cell interactions. Information based on bulk samples represents ensemble averages over populations of cells, while data generated from isolated single cells do not account for intercellular interactions. We describe a new technology and demonstrate two important advantages over existing technologies: first, it enables multiparameter energy metabolism profiling of small cell populations (<100 cells)-a sample size that is at least an order of magnitude smaller than other, commercially available technologies; second, it can perform simultaneous real-time measurements of oxygen consumption rate (OCR), extracellular acidification rate (ECAR), and mitochondrial membrane potential (MMP)-a capability not offered by any other commercially available technology. Our results revealed substantial diversity in response kinetics of the three analytes in dysplastic human epithelial esophageal cells and suggest the existence of varying cellular energy metabolism profiles and their kinetics among small populations of cells. The technology represents a powerful analytical tool for multiparameter studies of cellular function.
Research on the precision measurement of super-low reflectivity
NASA Astrophysics Data System (ADS)
Yuan, Hao-yu; Lu, Zong-gui; Xia, Yan-wen; Peng, Zhi-tao; Liu, Hua; Xu, Long-bo; Sun, Zhi-hong; Tang, Jun
2010-10-01
Introduced a high-precision measurement of measured the super-low reflectivity and small sampling angle. Using single reflect way measured, and compare with re-swatch. Testing the reflectance of the sampling mirror which be used on TIL, and analyze the error. Research results indicate, the main factor which affect result is energy detector error and energy detector linearity. This methods is easy and have high-precision, it can be used to measure the super-low reflectivity sampling mirror reflectance.
NASA Astrophysics Data System (ADS)
Urrutia-Fucugauchi, Jaime; Marin, Luis E.; Sharpton, Virgil L.; Quezada, Juan Manuel
1993-03-01
Further paleomagnetic data for core samples of melt rock recovered in the Petroleos Mexicanos (PEMEX) exploratory wells within the Chicxulub structure, northern Yucatan peninsula, Mexico are reported. A previous report by Sharpton showed that the rocks studied contain high iridium levels and shocked breccia clasts, and an Ar-40/Ar-39 age of 65.2 plus or minus 0.4 Ma. The geomagnetic polarity determined for two samples is reverse (R) and was correlated with chron 29R that includes the K/T boundary. Our present analysis is based on two samples from each of three clasts of the melt rock from PEMEX well Y6-N17 (1295 to 1299 m b.s.l.). This study concentrates on the vectorial nature and stability of the remanence (NRM), the magnetic mineralogy and remanence carriers (i.e., the reliability and origin of the record), and on the implications (correlation with expected paleolatitude and polarity). The relative orientation of the drill core samples with respect to the horizontal is known. Samples were stable under alternating field (AF) and thermal treatments, and after removal of a small component they exhibited single-vectorial behavior. The characteristic remanence inclinations show small dispersion and a mean value (-43 deg) in close agreement with the expected inclination and paleolatitude (derived from the North American apparent polar wander path). Isothermal remenence (IRM) acquisition experiments, Lowrie-Fuller tests, coercivity and unblocking temperature spectra of NRM and saturation IRM, susceptibility and Q-coefficient analyses, and the single-component nature indicate a dominant mineralogy of iron-rich titanomagnetites with single or pseduo-single domain states. The stable characteristic magnetization may be interpreted as a result of shock heating of the rock at the time of formation of the inpact structure and its polarity, age, and paleolatitude are consistent with a time about the K/T boundary.
NASA Technical Reports Server (NTRS)
Urrutia-Fucugauchi, Jaime; Marin, Luis E.; Sharpton, Virgil L.; Quezada, Juan Manuel
1993-01-01
Further paleomagnetic data for core samples of melt rock recovered in the Petroleos Mexicanos (PEMEX) exploratory wells within the Chicxulub structure, northern Yucatan peninsula, Mexico are reported. A previous report by Sharpton showed that the rocks studied contain high iridium levels and shocked breccia clasts, and an Ar-40/Ar-39 age of 65.2 plus or minus 0.4 Ma. The geomagnetic polarity determined for two samples is reverse (R) and was correlated with chron 29R that includes the K/T boundary. Our present analysis is based on two samples from each of three clasts of the melt rock from PEMEX well Y6-N17 (1295 to 1299 m b.s.l.). This study concentrates on the vectorial nature and stability of the remanence (NRM), the magnetic mineralogy and remanence carriers (i.e., the reliability and origin of the record), and on the implications (correlation with expected paleolatitude and polarity). The relative orientation of the drill core samples with respect to the horizontal is known. Samples were stable under alternating field (AF) and thermal treatments, and after removal of a small component they exhibited single-vectorial behavior. The characteristic remanence inclinations show small dispersion and a mean value (-43 deg) in close agreement with the expected inclination and paleolatitude (derived from the North American apparent polar wander path). Isothermal remenence (IRM) acquisition experiments, Lowrie-Fuller tests, coercivity and unblocking temperature spectra of NRM and saturation IRM, susceptibility and Q-coefficient analyses, and the single-component nature indicate a dominant mineralogy of iron-rich titanomagnetites with single or pseduo-single domain states. The stable characteristic magnetization may be interpreted as a result of shock heating of the rock at the time of formation of the inpact structure and its polarity, age, and paleolatitude are consistent with a time about the K/T boundary.
Capillary absorption spectrometer and process for isotopic analysis of small samples
Alexander, M. Lizabeth; Kelly, James F.; Sams, Robert L.; Moran, James J.; Newburn, Matthew K.; Blake, Thomas A.
2016-03-29
A capillary absorption spectrometer and process are described that provide highly sensitive and accurate stable absorption measurements of analytes in a sample gas that may include isotopologues of carbon and oxygen obtained from gas and biological samples. It further provides isotopic images of microbial communities that allow tracking of nutrients at the single cell level. It further targets naturally occurring variations in carbon and oxygen isotopes that avoids need for expensive isotopically labeled mixtures which allows study of samples taken from the field without modification. The method also permits sampling in vivo permitting real-time ambient studies of microbial communities.
Capillary absorption spectrometer and process for isotopic analysis of small samples
DOE Office of Scientific and Technical Information (OSTI.GOV)
Alexander, M. Lizabeth; Kelly, James F.; Sams, Robert L.
A capillary absorption spectrometer and process are described that provide highly sensitive and accurate stable absorption measurements of analytes in a sample gas that may include isotopologues of carbon and oxygen obtained from gas and biological samples. It further provides isotopic images of microbial communities that allow tracking of nutrients at the single cell level. It further targets naturally occurring variations in carbon and oxygen isotopes that avoids need for expensive isotopically labeled mixtures which allows study of samples taken from the field without modification. The process also permits sampling in vivo permitting real-time ambient studies of microbial communities.
Compartmental genomics in living cells revealed by single-cell nanobiopsy.
Actis, Paolo; Maalouf, Michelle M; Kim, Hyunsung John; Lohith, Akshar; Vilozny, Boaz; Seger, R Adam; Pourmand, Nader
2014-01-28
The ability to study the molecular biology of living single cells in heterogeneous cell populations is essential for next generation analysis of cellular circuitry and function. Here, we developed a single-cell nanobiopsy platform based on scanning ion conductance microscopy (SICM) for continuous sampling of intracellular content from individual cells. The nanobiopsy platform uses electrowetting within a nanopipette to extract cellular material from living cells with minimal disruption of the cellular milieu. We demonstrate the subcellular resolution of the nanobiopsy platform by isolating small subpopulations of mitochondria from single living cells, and quantify mutant mitochondrial genomes in those single cells with high throughput sequencing technology. These findings may provide the foundation for dynamic subcellular genomic analysis.
Poetzsch, Michael; Steuer, Andrea E; Roemmelt, Andreas T; Baumgartner, Markus R; Kraemer, Thomas
2014-12-02
Single hair analysis normally requires extensive sample preparation microscale protocols including time-consuming steps like segmentation and extraction. Matrix assisted laser desorption and ionization mass spectrometric imaging (MALDI-MSI) was shown to be an alternative tool in single hair analysis, but still, questions remain. Therefore, an investigation of MALDI-MSI in single hair analysis concerning the extraction process, usage of internal standard (IS), and influences on the ionization processes were systematically investigated to enable the reliable application to hair analysis. Furthermore, single dose detection, quantitative correlation to a single hair, and hair strand LC-MS/MS results were performed, and the performance was compared to LC-MS/MS single hair monitoring. The MALDI process was shown to be independent from natural hair color and not influenced by the presence of melanin. Ionization was shown to be reproducible along and in between different hair samples. MALDI image intensities in single hair and hair snippets showed good semiquantitative correlation to zolpidem hair concentrations obtained from validated routine LC-MS/MS methods. MALDI-MSI is superior to LC-MS/MS analysis when a fast, easy, and cheap sample preparation is necessary, whereas LC-MS/MS showed higher sensitivity with the ability of single dose detection for zolpidem. MALDI-MSI and LC-MS/MS segmental single hair analysis showed good correlation, and both are suitable for consumption monitoring of drugs of abuse with a high time resolution.
LAND USE AND SEASONAL EFFECTS ON URBAN STORMWATER RUNOFF MICROORGANISM CONCENTRATIONS
Stormwater samples collected from storm sewers draining small municipal separate storm sewer systems shown to be free of cross connections within an urban watershed dominated by a single land use were analyzed for pathogens (Pseudomonas aeruginosa and Staphylococcus aureus) and i...
Zettl, Thomas; Mathew, Rebecca S.; Seifert, Sönke; ...
2016-05-31
Accurate determination of molecular distances is fundamental to understanding the structure, dynamics, and conformational ensembles of biological macromolecules. Here we present a method to determine the full,distance,distribution between small (~7 Å) gold labels attached to macromolecules with very high-precision(≤1 Å) and on an absolute distance scale. Our method uses anomalous small-angle X-ray scattering close to a gold absorption edge to separate the gold-gold interference pattern from other scattering contributions. Results for 10-30 bp DNA constructs achieve excellent signal-to-noise and are in good agreement with previous results obtained by single-energy,SAXS measurements without requiring the preparation and measurement of single labeled andmore » unlabeled samples. Finally, the use of small gold labels in combination with ASAXS read out provides an attractive approach to determining molecular distance distributions that will be applicable to a broad range of macromolecular systems.« less
Fiber Bragg Grating Dilatometry in Extreme Magnetic Field and Cryogenic Conditions
Corvalán Moya, Carolina; Weickert, Franziska; Zapf, Vivien; Balakirev, Fedor F.; Wartenbe, Mark; Rosa, Priscila F. S.; Betts, Jonathan B.; Crooker, Scott A.; Daou, Ramzy
2017-01-01
In this work, we review single mode SiO2 fiber Bragg grating techniques for dilatometry studies of small single-crystalline samples in the extreme environments of very high, continuous, and pulsed magnetic fields of up to 150 T and at cryogenic temperatures down to <1 K. Distinct millimeter-long materials are measured as part of the technique development, including metallic, insulating, and radioactive compounds. Experimental strategies are discussed for the observation and analysis of the related thermal expansion and magnetostriction of materials, which can achieve a strain sensitivity (ΔL/L) as low as a few parts in one hundred million (≈10−8). The impact of experimental artifacts, such as those originating in the temperature dependence of the fiber’s index of diffraction, light polarization rotation in magnetic fields, and reduced strain transfer from millimeter-long specimens, is analyzed quantitatively using analytic models available in the literature. We compare the experimental results with model predictions in the small-sample limit, and discuss the uncovered discrepancies. PMID:29117137
Fiber Bragg Grating Dilatometry in Extreme Magnetic Field and Cryogenic Conditions.
Jaime, Marcelo; Corvalán Moya, Carolina; Weickert, Franziska; Zapf, Vivien; Balakirev, Fedor F; Wartenbe, Mark; Rosa, Priscila F S; Betts, Jonathan B; Rodriguez, George; Crooker, Scott A; Daou, Ramzy
2017-11-08
In this work, we review single mode SiO₂ fiber Bragg grating techniques for dilatometry studies of small single-crystalline samples in the extreme environments of very high, continuous, and pulsed magnetic fields of up to 150 T and at cryogenic temperatures down to <1 K. Distinct millimeter-long materials are measured as part of the technique development, including metallic, insulating, and radioactive compounds. Experimental strategies are discussed for the observation and analysis of the related thermal expansion and magnetostriction of materials, which can achieve a strain sensitivity ( ΔL/L ) as low as a few parts in one hundred million (≈10 -8 ). The impact of experimental artifacts, such as those originating in the temperature dependence of the fiber's index of diffraction, light polarization rotation in magnetic fields, and reduced strain transfer from millimeter-long specimens, is analyzed quantitatively using analytic models available in the literature. We compare the experimental results with model predictions in the small-sample limit, and discuss the uncovered discrepancies.
Fiber Bragg Grating Dilatometry in Extreme Magnetic Field and Cryogenic Conditions
Jaime, Marcelo; Corvalán Moya, Carolina; Weickert, Franziska; ...
2017-11-08
In this work, we review single mode SiO 2 fiber Bragg grating techniques for dilatometry studies of small single-crystalline samples in the extreme environments of very high, continuous, and pulsed magnetic fields of up to 150 T and at cryogenic temperatures down to <1 K. Distinct millimeter-long materials are measured as part of the technique development, including metallic, insulating, and radioactive compounds. Experimental strategies are discussed for the observation and analysis of the related thermal expansion and magnetostriction of materials, which can achieve a strain sensitivity (ΔL/L) as low as a few parts in one hundred million (≈10 -8). Themore » impact of experimental artifacts, such as those originating in the temperature dependence of the fiber’s index of diffraction, light polarization rotation in magnetic fields, and reduced strain transfer from millimeter-long specimens, is analyzed quantitatively using analytic models available in the literature. We compare the experimental results with model predictions in the small-sample limit, and discuss the uncovered discrepancies.« less
Mars Sample Return and Flight Test of a Small Bimodal Nuclear Rocket and ISRU Plant
NASA Technical Reports Server (NTRS)
George, Jeffrey A.; Wolinsky, Jason J.; Bilyeu, Michael B.; Scott, John H.
2014-01-01
A combined Nuclear Thermal Rocket (NTR) flight test and Mars Sample Return mission (MSR) is explored as a means of "jump-starting" NTR development. Development of a small-scale engine with relevant fuel and performance could more affordably and quickly "pathfind" the way to larger scale engines. A flight test with subsequent inflight postirradiation evaluation may also be more affordable and expedient compared to ground testing and associated facilities and approvals. Mission trades and a reference scenario based upon a single expendable launch vehicle (ELV) are discussed. A novel "single stack" spacecraft/lander/ascent vehicle concept is described configured around a "top-mounted" downward firing NTR, reusable common tank, and "bottom-mount" bus, payload and landing gear. Requirements for a hypothetical NTR engine are described that would be capable of direct thermal propulsion with either hydrogen or methane propellant, and modest electrical power generation during cruise and Mars surface insitu resource utilization (ISRU) propellant production.
Effect of Hf-Rich Particles on the Creep Life of a High-strength Nial Single Crystal Alloy
NASA Technical Reports Server (NTRS)
Garg, A.; Raj, S. V.; Darolia, R.
1995-01-01
Additions of small amounts of Hf and Si to NiAl single crystals significantly improve their high-temperature strength and creep properties. However, if large Hf-rich dendritic particles formed during casting of the alloyed single crystals are not dissolved completely during homogenization heat treatment, a large variation in creep rupture life can occur. This behavior, observed in five samples of a Hf containing NiAl single crystal alloy tested at 1144 K under an initial stress of 241.4 MPa, is described in detail highlighting the role of interdendritic Hf-rich particles in limiting creep rupture life.
Lesser-Rojas, Leonardo; Sriram, K. K.; Liao, Kuo-Tang; Lai, Shui-Chin; Kuo, Pai-Chia; Chu, Ming-Lee; Chou, Chia-Fu
2014-01-01
We have developed a two-step electron-beam lithography process to fabricate a tandem array of three pairs of tip-like gold nanoelectronic detectors with electrode gap size as small as 9 nm, embedded in a coplanar fashion to 60 nm deep, 100 nm wide, and up to 150 μm long nanochannels coupled to a world-micro-nanofluidic interface for easy sample introduction. Experimental tests with a sealed device using DNA-protein complexes demonstrate the coplanarity of the nanoelectrodes to the nanochannel surface. Further, this device could improve transverse current detection by correlated time-of-flight measurements of translocating samples, and serve as an autocalibrated velocimeter and nanoscale tandem Coulter counters for single molecule analysis of heterogeneous samples. PMID:24753731
A Portable Solid-State Moisture Meter For Agricultural And Food Products
NASA Astrophysics Data System (ADS)
Bull, C. R.; Stafford, J. V.; Weaving, G. S.
1988-10-01
This paper reports on the development of a small, robust, battery operated near infra-red (NIR) reflectance device, designed for rapid on-farm measurement of the moisture content of forage crops without prior sample preparation. It has potential application to other agricultural or food materials. The instrument is based on two light emitting diodes (LEDs), a germanium detector and a control CMOS single chip microcomputer. The meter has been calibrated to give a direct read out of moisture content for 4 common grass varieties at 3 stages of development. The accuracy of a single point measurement on a grass sample is approximately +/- 6% over a range of 40-80% (wet basis). However, the potential accuracy on a homogeous sample may be as goon as 0.15%.
Ar-Ar Thermochronlogy of Apollo 12 Impact-Melt Breccia 12033,638-1
NASA Technical Reports Server (NTRS)
Crow, C. A.; Cassata, W. S.; Jolliff, B. L.; Ziegler, R. A.; Borg, L. E.; Shearer, C. K.
2017-01-01
We have undertaken an Ar-Ar thermochronology investigation as part of a coordinated multichronometer analysis of a single Apollo 12 impact- melt breccia to demonstrate the wide range of information that can be obtained for a single complex rock. This has implications for the age of formation, component makeup, and subsequent impact/shock and exposure history of the sample. This study also serves as a capabilities demonstration for the proposed MoonRise Mission [1]. The goal of this investigation is to elucidate the history of this sample through coordinated 40Ar*/39Ar, Sm-Nd, Rb-Sr and zircon 207Pb-206Pb ages along with geochemical and petrographic context on a relatively small (approximately 450 mg) sample. Here, we report preliminary results of the Ar-Ar thermochronology.
Total Extracellular Small RNA Profiles from Plasma, Saliva, and Urine of Healthy Subjects
Yeri, Ashish; Courtright, Amanda; Reiman, Rebecca; Carlson, Elizabeth; Beecroft, Taylor; Janss, Alex; Siniard, Ashley; Richholt, Ryan; Balak, Chris; Rozowsky, Joel; Kitchen, Robert; Hutchins, Elizabeth; Winarta, Joseph; McCoy, Roger; Anastasi, Matthew; Kim, Seungchan; Huentelman, Matthew; Van Keuren-Jensen, Kendall
2017-01-01
Interest in circulating RNAs for monitoring and diagnosing human health has grown significantly. There are few datasets describing baseline expression levels for total cell-free circulating RNA from healthy control subjects. In this study, total extracellular RNA (exRNA) was isolated and sequenced from 183 plasma samples, 204 urine samples and 46 saliva samples from 55 male college athletes ages 18–25 years. Many participants provided more than one sample, allowing us to investigate variability in an individual’s exRNA expression levels over time. Here we provide a systematic analysis of small exRNAs present in each biofluid, as well as an analysis of exogenous RNAs. The small RNA profile of each biofluid is distinct. We find that a large number of RNA fragments in plasma (63%) and urine (54%) have sequences that are assigned to YRNA and tRNA fragments respectively. Surprisingly, while many miRNAs can be detected, there are few miRNAs that are consistently detected in all samples from a single biofluid, and profiles of miRNA are different for each biofluid. Not unexpectedly, saliva samples have high levels of exogenous sequence that can be traced to bacteria. These data significantly contribute to the current number of sequenced exRNA samples from normal healthy individuals. PMID:28303895
Low-Dead-Volume Inlet for Vacuum Chamber
NASA Technical Reports Server (NTRS)
Naylor, Guy; Arkin, C.
2010-01-01
Gas introduction from near-ambient pressures to high vacuum traditionally is accomplished either by multi-stage differential pumping that allows for very rapid response, or by a capillary method that allows for a simple, single-stage introduction, but which often has a delayed response. Another means to introduce the gas sample is to use the multi-stage design with only a single stage. This is accomplished by using a very small conductance limit. The problem with this method is that a small conductance limit will amplify issues associated with dead -volume. As a result, a high -vacuum gas inlet was developed with low dead -volume, allowing the use of a very low conductance limit interface. Gas flows through the ConFlat flange at a relatively high flow rate at orders of magnitude greater than through the conductance limit. The small flow goes through a conductance limit that is a double-sided ConFlat.
Low-Dead-Volume Inlet for Vacuum Chamber
NASA Technical Reports Server (NTRS)
Naylor, Guy; Arkin, C.
2011-01-01
Gas introduction from near-ambient pressures to high vacuum traditionally is accomplished either by multi-stage differential pumping that allows for very rapid response, or by a capillary method that allows for a simple, single-stage introduction, but which often has a delayed response. Another means to introduce the gas sample is to use the multi-stage design with only a single stage. This is accomplished by using a very small conductance limit. The problem with this method is that a small conductance limit will amplify issues associated with dead-volume. As a result, a high-vacuum gas inlet was developed with low dead-volume, allowing the use of a very low conductance limit interface. Gas flows through the ConFlat flange at a relatively high flow rate at orders of magnitude greater than through the conductance limit. The small flow goes through a conductance limit that is a double-sided ConFlat.
Liebi, Marianne; Georgiadis, Marios; Kohlbrecher, Joachim; Holler, Mirko; Raabe, Jörg; Usov, Ivan; Menzel, Andreas; Schneider, Philipp; Bunk, Oliver; Guizar-Sicairos, Manuel
2018-01-01
Small-angle X-ray scattering tensor tomography, which allows reconstruction of the local three-dimensional reciprocal-space map within a three-dimensional sample as introduced by Liebi et al. [Nature (2015), 527, 349-352], is described in more detail with regard to the mathematical framework and the optimization algorithm. For the case of trabecular bone samples from vertebrae it is shown that the model of the three-dimensional reciprocal-space map using spherical harmonics can adequately describe the measured data. The method enables the determination of nanostructure orientation and degree of orientation as demonstrated previously in a single momentum transfer q range. This article presents a reconstruction of the complete reciprocal-space map for the case of bone over extended ranges of q. In addition, it is shown that uniform angular sampling and advanced regularization strategies help to reduce the amount of data required.
Single-cell DNA methylome sequencing and bioinformatic inference of epigenomic cell-state dynamics.
Farlik, Matthias; Sheffield, Nathan C; Nuzzo, Angelo; Datlinger, Paul; Schönegger, Andreas; Klughammer, Johanna; Bock, Christoph
2015-03-03
Methods for single-cell genome and transcriptome sequencing have contributed to our understanding of cellular heterogeneity, whereas methods for single-cell epigenomics are much less established. Here, we describe a whole-genome bisulfite sequencing (WGBS) assay that enables DNA methylation mapping in very small cell populations (μWGBS) and single cells (scWGBS). Our assay is optimized for profiling many samples at low coverage, and we describe a bioinformatic method that analyzes collections of single-cell methylomes to infer cell-state dynamics. Using these technological advances, we studied epigenomic cell-state dynamics in three in vitro models of cellular differentiation and pluripotency, where we observed characteristic patterns of epigenome remodeling and cell-to-cell heterogeneity. The described method enables single-cell analysis of DNA methylation in a broad range of biological systems, including embryonic development, stem cell differentiation, and cancer. It can also be used to establish composite methylomes that account for cell-to-cell heterogeneity in complex tissue samples. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.
Opportunities for bead-based multiplex assays in veterinary diagnostic laboratories
USDA-ARS?s Scientific Manuscript database
Bead based multiplex assays (BBMA) also referred to as Luminex, MultiAnalyte Profiling or cytometric bead array (CBA) assays, are applicable for high throughput, simultaneous detection of multiple analytes in solution (from several, up to 50-500 analytes within a single, small sample volume). Curren...
Cast aluminium single crystals cross the threshold from bulk to size-dependent stochastic plasticity
NASA Astrophysics Data System (ADS)
Krebs, J.; Rao, S. I.; Verheyden, S.; Miko, C.; Goodall, R.; Curtin, W. A.; Mortensen, A.
2017-07-01
Metals are known to exhibit mechanical behaviour at the nanoscale different to bulk samples. This transition typically initiates at the micrometre scale, yet existing techniques to produce micrometre-sized samples often introduce artefacts that can influence deformation mechanisms. Here, we demonstrate the casting of micrometre-scale aluminium single-crystal wires by infiltration of a salt mould. Samples have millimetre lengths, smooth surfaces, a range of crystallographic orientations, and a diameter D as small as 6 μm. The wires deform in bursts, at a stress that increases with decreasing D. Bursts greater than 200 nm account for roughly 50% of wire deformation and have exponentially distributed intensities. Dislocation dynamics simulations show that single-arm sources that produce large displacement bursts halted by stochastic cross-slip and lock formation explain microcast wire behaviour. This microcasting technique may be extended to several other metals or alloys and offers the possibility of exploring mechanical behaviour spanning the micrometre scale.
Hao, Pengyu; Wang, Li; Niu, Zheng
2015-01-01
A range of single classifiers have been proposed to classify crop types using time series vegetation indices, and hybrid classifiers are used to improve discriminatory power. Traditional fusion rules use the product of multi-single classifiers, but that strategy cannot integrate the classification output of machine learning classifiers. In this research, the performance of two hybrid strategies, multiple voting (M-voting) and probabilistic fusion (P-fusion), for crop classification using NDVI time series were tested with different training sample sizes at both pixel and object levels, and two representative counties in north Xinjiang were selected as study area. The single classifiers employed in this research included Random Forest (RF), Support Vector Machine (SVM), and See 5 (C 5.0). The results indicated that classification performance improved (increased the mean overall accuracy by 5%~10%, and reduced standard deviation of overall accuracy by around 1%) substantially with the training sample number, and when the training sample size was small (50 or 100 training samples), hybrid classifiers substantially outperformed single classifiers with higher mean overall accuracy (1%~2%). However, when abundant training samples (4,000) were employed, single classifiers could achieve good classification accuracy, and all classifiers obtained similar performances. Additionally, although object-based classification did not improve accuracy, it resulted in greater visual appeal, especially in study areas with a heterogeneous cropping pattern. PMID:26360597
Low-energy transmission electron diffraction and imaging of large-area graphene
Zhao, Wei; Xia, Bingyu; Lin, Li; Xiao, Xiaoyang; Liu, Peng; Lin, Xiaoyang; Peng, Hailin; Zhu, Yuanmin; Yu, Rong; Lei, Peng; Wang, Jiangtao; Zhang, Lina; Xu, Yong; Zhao, Mingwen; Peng, Lianmao; Li, Qunqing; Duan, Wenhui; Liu, Zhongfan; Fan, Shoushan; Jiang, Kaili
2017-01-01
Two-dimensional (2D) materials have attracted interest because of their excellent properties and potential applications. A key step in realizing industrial applications is to synthesize wafer-scale single-crystal samples. Until now, single-crystal samples, such as graphene domains up to the centimeter scale, have been synthesized. However, a new challenge is to efficiently characterize large-area samples. Currently, the crystalline characterization of these samples still relies on selected-area electron diffraction (SAED) or low-energy electron diffraction (LEED), which is more suitable for characterizing very small local regions. This paper presents a highly efficient characterization technique that adopts a low-energy electrostatically focused electron gun and a super-aligned carbon nanotube (SACNT) film sample support. It allows rapid crystalline characterization of large-area graphene through a single photograph of a transmission-diffracted image at a large beam size. Additionally, the low-energy electron beam enables the observation of a unique diffraction pattern of adsorbates on the suspended graphene at room temperature. This work presents a simple and convenient method for characterizing the macroscopic structures of 2D materials, and the instrument we constructed allows the study of the weak interaction with 2D materials. PMID:28879233
Low-energy transmission electron diffraction and imaging of large-area graphene.
Zhao, Wei; Xia, Bingyu; Lin, Li; Xiao, Xiaoyang; Liu, Peng; Lin, Xiaoyang; Peng, Hailin; Zhu, Yuanmin; Yu, Rong; Lei, Peng; Wang, Jiangtao; Zhang, Lina; Xu, Yong; Zhao, Mingwen; Peng, Lianmao; Li, Qunqing; Duan, Wenhui; Liu, Zhongfan; Fan, Shoushan; Jiang, Kaili
2017-09-01
Two-dimensional (2D) materials have attracted interest because of their excellent properties and potential applications. A key step in realizing industrial applications is to synthesize wafer-scale single-crystal samples. Until now, single-crystal samples, such as graphene domains up to the centimeter scale, have been synthesized. However, a new challenge is to efficiently characterize large-area samples. Currently, the crystalline characterization of these samples still relies on selected-area electron diffraction (SAED) or low-energy electron diffraction (LEED), which is more suitable for characterizing very small local regions. This paper presents a highly efficient characterization technique that adopts a low-energy electrostatically focused electron gun and a super-aligned carbon nanotube (SACNT) film sample support. It allows rapid crystalline characterization of large-area graphene through a single photograph of a transmission-diffracted image at a large beam size. Additionally, the low-energy electron beam enables the observation of a unique diffraction pattern of adsorbates on the suspended graphene at room temperature. This work presents a simple and convenient method for characterizing the macroscopic structures of 2D materials, and the instrument we constructed allows the study of the weak interaction with 2D materials.
Single sample resolution of rare microbial dark matter in a marine invertebrate metagenome
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miller, Ian J.; Weyna, Theodore R.; Fong, Stephen S.
Direct, untargeted sequencing of environmental samples (metagenomics) and de novo genome assembly enable the study of uncultured and phylogenetically divergent organisms. However, separating individual genomes from a mixed community has often relied on the differential-coverage analysis of multiple, deeply sequenced samples. In the metagenomic investigation of the marine bryozoan Bugula neritina, we uncovered seven bacterial genomes associated with a single B. neritina individual that appeared to be transient associates, two of which were unique to one individual and undetectable using certain “universal” 16S rRNA primers and probes. We recovered high quality genome assemblies for several rare instances of “microbial darkmore » matter,” or phylogenetically divergent bacteria lacking genomes in reference databases, from a single tissue sample that was not subjected to any physical or chemical pre-treatment. One of these rare, divergent organisms has a small (593 kbp), poorly annotated genome with low GC content (20.9%) and a 16S rRNA gene with just 65% sequence similarity to the closest reference sequence. Lastly, our findings illustrate the importance of sampling strategy and de novo assembly of metagenomic reads to understand the extent and function of bacterial biodiversity.« less
Single sample resolution of rare microbial dark matter in a marine invertebrate metagenome
Miller, Ian J.; Weyna, Theodore R.; Fong, Stephen S.; ...
2016-09-29
Direct, untargeted sequencing of environmental samples (metagenomics) and de novo genome assembly enable the study of uncultured and phylogenetically divergent organisms. However, separating individual genomes from a mixed community has often relied on the differential-coverage analysis of multiple, deeply sequenced samples. In the metagenomic investigation of the marine bryozoan Bugula neritina, we uncovered seven bacterial genomes associated with a single B. neritina individual that appeared to be transient associates, two of which were unique to one individual and undetectable using certain “universal” 16S rRNA primers and probes. We recovered high quality genome assemblies for several rare instances of “microbial darkmore » matter,” or phylogenetically divergent bacteria lacking genomes in reference databases, from a single tissue sample that was not subjected to any physical or chemical pre-treatment. One of these rare, divergent organisms has a small (593 kbp), poorly annotated genome with low GC content (20.9%) and a 16S rRNA gene with just 65% sequence similarity to the closest reference sequence. Lastly, our findings illustrate the importance of sampling strategy and de novo assembly of metagenomic reads to understand the extent and function of bacterial biodiversity.« less
Re-electrospraying splash-landed proteins and nanoparticles.
Benner, W Henry; Lewis, Gregory S; Hering, Susanne V; Selgelke, Brent; Corzett, Michelle; Evans, James E; Lightstone, Felice C
2012-03-06
FITC-albumin, Lsr-F, or fluorescent polystyrene latex particles were electrosprayed from aqueous buffer and subjected to dispersion by differential electrical mobility at atmospheric pressure. A resulting narrow size cut of singly charged molecular ions or particles was passed through a condensation growth tube collector to create a flow stream of small water droplets, each carrying a single ion or particle. The droplets were splash landed (impacted) onto a solid or liquid temperature controlled surface. Small pools of droplets containing size-selected particles, FITC-albumin, or Lsr-F were recovered, re-electrosprayed, and, when analyzed a second time by differential electrical mobility, showed increased homogeneity. Transmission electron microscopy (TEM) analysis of the size-selected Lsr-F sample corroborated the mobility observation.
NASA Technical Reports Server (NTRS)
Davis, S. H.; Kissinger, L. D.
1978-01-01
The effect of humidity on the CO2 removal efficiency of small beds of anhydrous LiOH has been studied. Experimental data taken in this small bed system clearly show that there is an optimum humidity for beds loaded with LiOH from a single lot. The CO2 efficiency falls rapidly under dry conditions, but this behavior is approximately the same in all samples. The behavior of the bed under wet conditions is quite dependent on material size distribution. The presence of large particles in a sample can lead to rapid fall off in the CO2 efficiency as the humidity increases.
Fu, Glenn K; Wilhelmy, Julie; Stern, David; Fan, H Christina; Fodor, Stephen P A
2014-03-18
We present a new approach for the sensitive detection and accurate quantitation of messenger ribonucleic acid (mRNA) gene transcripts in single cells. First, the entire population of mRNAs is encoded with molecular barcodes during reverse transcription. After amplification of the gene targets of interest, molecular barcodes are counted by sequencing or scored on a simple hybridization detector to reveal the number of molecules in the starting sample. Since absolute quantities are measured, calibration to standards is unnecessary, and many of the relative quantitation challenges such as polymerase chain reaction (PCR) bias are avoided. We apply the method to gene expression analysis of minute sample quantities and demonstrate precise measurements with sensitivity down to sub single-cell levels. The method is an easy, single-tube, end point assay utilizing standard thermal cyclers and PCR reagents. Accurate and precise measurements are obtained without any need for cycle-to-cycle intensity-based real-time monitoring or physical partitioning into multiple reactions (e.g., digital PCR). Further, since all mRNA molecules are encoded with molecular barcodes, amplification can be used to generate more material for multiple measurements and technical replicates can be carried out on limited samples. The method is particularly useful for small sample quantities, such as single-cell experiments. Digital encoding of cellular content preserves true abundance levels and overcomes distortions introduced by amplification.
Bei, Hongbin; Xia, Yuzhi; Barabash, Rozaliya; ...
2015-08-10
Pre-straining defect-free single crystals will introduce heterogeneous dislocation nucleation sources that reduce the measured strength from the theoretical value, while pre-straining bulk samples will lead to strain hardening. Their competition is investigated by nanoindentation pop-in tests on variously pre-strained Mo single crystals with several indenter radii (~micrometer). Pre-straining primarily shifts deformation mechanism from homogeneous dislocation nucleation to a stochastic behavior, while strain hardening plays a secondary role, as summarized in a master plot of pop-in strength versus normalized indenter radius.
Early Handedness in Infancy Predicts Language Ability in Toddlers
ERIC Educational Resources Information Center
Nelson, Eliza L.; Campbell, Julie M.; Michel, George F.
2014-01-01
Researchers have long been interested in the relationship between handedness and language in development. However, traditional handedness studies using single age groups, small samples, or too few measurement time points have not capitalized on individual variability and may have masked 2 recently identified patterns in infants: those with a…
Big Results from Small Samples: Evaluation of Amplification Protocols for Gene Expression Profiling
Microarrays have revolutionized many areas of biology due to our technical ability to quantify tens of thousands of transcripts within a single experiment. However, there are still many areas that cannot benefit from this technology due to the amount of biological material needed...
Pisarska, Margareta D; Akhlaghpour, Marzieh; Lee, Bora; Barlow, Gillian M; Xu, Ning; Wang, Erica T; Mackey, Aaron J; Farber, Charles R; Rich, Stephen S; Rotter, Jerome I; Chen, Yii-der I; Goodarzi, Mark O; Guller, Seth; Williams, John
2016-11-01
Multiple testing to understand global changes in gene expression based on genetic and epigenetic modifications is evolving. Chorionic villi, obtained for prenatal testing, is limited, but can be used to understand ongoing human pregnancies. However, optimal storage, processing and utilization of CVS for multiple platform testing have not been established. Leftover CVS samples were flash-frozen or preserved in RNAlater. Modifications to standard isolation kits were performed to isolate quality DNA and RNA from samples as small as 2-5 mg. RNAlater samples had significantly higher RNA yields and quality and were successfully used in microarray and RNA-sequencing (RNA-seq). RNA-seq libraries generated using 200 versus 800-ng RNA showed similar biological coefficients of variation. RNAlater samples had lower DNA yields and quality, which improved by heating the elution buffer to 70 °C. Purification of DNA was not necessary for bisulfite-conversion and genome-wide methylation profiling. CVS cells were propagated and continue to express genes found in freshly isolated chorionic villi. CVS samples preserved in RNAlater are superior. Our optimized techniques provide specimens for genetic, epigenetic and gene expression studies from a single small sample which can be used to develop diagnostics and treatments using a systems biology approach in the prenatal period. © 2016 John Wiley & Sons, Ltd. © 2016 John Wiley & Sons, Ltd.
Compartmental Genomics in Living Cells Revealed by Single-Cell Nanobiopsy
Actis, Paolo; Maalouf, Michelle; Kim, Hyunsung John; Lohith, Akshar; Vilozny, Boaz; Seger, R. Adam; Pourmand, Nader
2014-01-01
The ability to study the molecular biology of living single cells in heterogeneous cell populations is essential for next generation analysis of cellular circuitry and function. Here, we developed a single-cell nanobiopsy platform based on scanning ion conductance microscopy (SICM) for continuous sampling of intracellular content from individual cells. The nanobiopsy platform uses electrowetting within a nanopipette to extract cellular material from living cells with minimal disruption of the cellular milieu. We demonstrate the subcellular resolution of the nanobiopsy platform by isolating small subpopulations of mitochondria from single living cells, and quantify mutant mitochondrial genomes in those single cells with high throughput sequencing technology. These findings may provide the foundation for dynamic subcellular genomic analysis. PMID:24279711
Evaluation of residual uranium contamination in the dirt floor of an abandoned metal rolling mill.
Glassford, Eric; Spitz, Henry; Lobaugh, Megan; Spitler, Grant; Succop, Paul; Rice, Carol
2013-02-01
A single, large, bulk sample of uranium-contaminated material from the dirt floor of an abandoned metal rolling mill was separated into different types and sizes of aliquots to simulate samples that would be collected during site remediation. The facility rolled approximately 11,000 tons of hot-forged ingots of uranium metal approximately 60 y ago, and it has not been used since that time. Thirty small mass (≈ 0.7 g) and 15 large mass (≈ 70 g) samples were prepared from the heterogeneously contaminated bulk material to determine how measurements of the uranium contamination vary with sample size. Aliquots of bulk material were also resuspended in an exposure chamber to produce six samples of respirable particles that were obtained using a cascade impactor. Samples of removable surface contamination were collected by wiping 100 cm of the interior surfaces of the exposure chamber with 47-mm-diameter fiber filters. Uranium contamination in each of the samples was measured directly using high-resolution gamma ray spectrometry. As expected, results for isotopic uranium (i.e., U and U) measured with the large-mass and small-mass samples are significantly different (p < 0.001), and the coefficient of variation (COV) for the small-mass samples was greater than for the large-mass samples. The uranium isotopic concentrations measured in the air and on the wipe samples were not significantly different and were also not significantly different (p > 0.05) from results for the large- or small-mass samples. Large-mass samples are more reliable for characterizing heterogeneously distributed radiological contamination than small-mass samples since they exhibit the least variation compared to the mean. Thus, samples should be sufficiently large in mass to insure that the results are truly representative of the heterogeneously distributed uranium contamination present at the facility. Monitoring exposure of workers and the public as a result of uranium contamination resuspended during site remediation should be evaluated using samples of sufficient size and type to accommodate the heterogeneous distribution of uranium in the bulk material.
Structural differences between single crystal and polycrystalline UBe 13
DOE Office of Scientific and Technical Information (OSTI.GOV)
Volz, Heather Michelle; Vogel, Sven C.; Smith, Alice Iulia
Here, we report on observations of structural and chemical differences between samples of UBe 13 that were synthesised using two different methods. Unexplained discrepancies in properties between samples with differing synthesis had previously been found in this heavy fermion superconductor. A polycrystalline UBe13 sample was made by arc-melting the constituents. Single crystals were grown using an aluminium flux and had a consistently slightly larger lattice parameter than the polycrystals, which merited further study. Neutron diffraction data were collected at the Lujan Center at LANSCE on the HIPPO diffractometer. Aluminium was detected by inductively coupled plasma mass spectrometry (ICP-MS) in themore » flux-grown single crystal (0.803 wt%), and small amounts (~0.2 wt%) of thorium were detected in the UBe 13 polycrystalline sample. In order to probe the implications of the presence of Al, calculations by spin-polarised DFT-GGA+U show that the incorporation of Al onto the 96i site (the lowest symmetry site in the structure) is energetically more favourable than on other sites. In general, the trends calculated by DFT for bond lengths and lattice parameter increases are consistent with bond lengths experimentally observed by neutron diffraction, but specific percentage changes with aluminium incorporation may be obscured by the unexpected thorium in the polycrystalline sample. The aggregate of our initial observations suggests that incorporation of aluminium from the flux into single crystal UBe 13 is significant.« less
Structural differences between single crystal and polycrystalline UBe 13
Volz, Heather Michelle; Vogel, Sven C.; Smith, Alice Iulia; ...
2018-05-16
Here, we report on observations of structural and chemical differences between samples of UBe 13 that were synthesised using two different methods. Unexplained discrepancies in properties between samples with differing synthesis had previously been found in this heavy fermion superconductor. A polycrystalline UBe13 sample was made by arc-melting the constituents. Single crystals were grown using an aluminium flux and had a consistently slightly larger lattice parameter than the polycrystals, which merited further study. Neutron diffraction data were collected at the Lujan Center at LANSCE on the HIPPO diffractometer. Aluminium was detected by inductively coupled plasma mass spectrometry (ICP-MS) in themore » flux-grown single crystal (0.803 wt%), and small amounts (~0.2 wt%) of thorium were detected in the UBe 13 polycrystalline sample. In order to probe the implications of the presence of Al, calculations by spin-polarised DFT-GGA+U show that the incorporation of Al onto the 96i site (the lowest symmetry site in the structure) is energetically more favourable than on other sites. In general, the trends calculated by DFT for bond lengths and lattice parameter increases are consistent with bond lengths experimentally observed by neutron diffraction, but specific percentage changes with aluminium incorporation may be obscured by the unexpected thorium in the polycrystalline sample. The aggregate of our initial observations suggests that incorporation of aluminium from the flux into single crystal UBe 13 is significant.« less
Laber, Eric B; Zhao, Ying-Qi; Regh, Todd; Davidian, Marie; Tsiatis, Anastasios; Stanford, Joseph B; Zeng, Donglin; Song, Rui; Kosorok, Michael R
2016-04-15
A personalized treatment strategy formalizes evidence-based treatment selection by mapping patient information to a recommended treatment. Personalized treatment strategies can produce better patient outcomes while reducing cost and treatment burden. Thus, among clinical and intervention scientists, there is a growing interest in conducting randomized clinical trials when one of the primary aims is estimation of a personalized treatment strategy. However, at present, there are no appropriate sample size formulae to assist in the design of such a trial. Furthermore, because the sampling distribution of the estimated outcome under an estimated optimal treatment strategy can be highly sensitive to small perturbations in the underlying generative model, sample size calculations based on standard (uncorrected) asymptotic approximations or computer simulations may not be reliable. We offer a simple and robust method for powering a single stage, two-armed randomized clinical trial when the primary aim is estimating the optimal single stage personalized treatment strategy. The proposed method is based on inverting a plugin projection confidence interval and is thereby regular and robust to small perturbations of the underlying generative model. The proposed method requires elicitation of two clinically meaningful parameters from clinical scientists and uses data from a small pilot study to estimate nuisance parameters, which are not easily elicited. The method performs well in simulated experiments and is illustrated using data from a pilot study of time to conception and fertility awareness. Copyright © 2015 John Wiley & Sons, Ltd.
NASA Astrophysics Data System (ADS)
Raju, C.; Vidya, R.
2017-11-01
Chain Sampling Plan is widely used whenever a small sample attributes plan is required to be used for situations involving destructive products coming out of continuous production process [1, 2]. This paper presents a procedure for the construction and selection of a ChSP-1 by attributes inspection based on membership functions [3]. A procedure using search technique is developed for obtaining the parameters of single sampling plan for a given set of AQL and LQL values. A sample of tables providing ChSP-1 plans for various combinations of AQL and LQL values are presented [4].
NASA Astrophysics Data System (ADS)
Santos, Sergio; Barcons, Victor; Christenson, Hugo K.; Billingsley, Daniel J.; Bonass, William A.; Font, Josep; Thomson, Neil H.
2013-08-01
A way to operate fundamental mode amplitude modulation atomic force microscopy is introduced which optimizes stability and resolution for a given tip size and shows negligible tip wear over extended time periods (˜24 h). In small amplitude small set-point (SASS) imaging, the cantilever oscillates with sub-nanometer amplitudes in the proximity of the sample, without the requirement of using large drive forces, as the dynamics smoothly lead the tip to the surface through the water layer. SASS is demonstrated on single molecules of double-stranded DNA in ambient conditions where sharp silicon tips (R ˜ 2-5 nm) can resolve the right-handed double helix.
A 4-spot time-of-flight anemometer for small centrifugal compressor velocity measurements
NASA Technical Reports Server (NTRS)
Wernet, Mark P.; Skoch, Gary J.
1992-01-01
The application of laser anemometry techniques in turbomachinery facilities is a challenging dilemma requiring an anemometer system with special qualities. Here, we describe the use of a novel laser anemometry technique applied to a small 4.5 kg/s, 4:1 pressure ratio centrifugal compressor. Sample velocity profiles across the blade pitch are presented for a single location along the rotor. The results of the intra-blade passage velocity measurements will ultimately be used to verify CFD 3-D viscous code predictions.
A 4-spot time-of-flight anemometer for small centrifugal compressor velocity measurements
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wernet, M.P.; Skoch, G.J.
1992-07-01
The application of laser anemometry techniques in turbomachinery facilities is a challenging dilemma requiring an anemometer system with special qualities. Here, we describe the use of a novel laser anemometry technique applied to a small 4.5 kg/s, 4:1 pressure ratio centrifugal compressor. Sample velocity profiles across the blade pitch are presented for a single location along the rotor. The results of the intra-blade passage velocity measurements will ultimately be used to verify CFD 3-D viscous code predictions.
A primer set to determine sex in the small Indian mongoose, Herpestes auropunctatus.
Murata, C; Ogura, G; Kuroiwa, A
2011-03-01
To enable the accurate sexing of individuals of introduced populations of the small Indian mongoose, Herpestes auropunctatus, we designed a primer set for the amplification of the sex-specific fragments EIF2S3Y and EIF2S3X. Using this primer set, the expected amplification products were obtained for all samples of genomic DNA tested: males yielded two bands and females a single band. Sequencing of each PCR product confirmed that the 769-bp fragment amplified from DNA samples of both sexes was derived from EIF2S3X, whereas the 546-bp fragment amplified only from male DNA samples was derived from EIF2S3Y. The results indicated that this primer set is useful for sex identification in this species. © 2010 Blackwell Publishing Ltd.
Brown, Philip J; Mannava, Sandeep; Seyler, Thorsten M; Plate, Johannes F; Van Sikes, Charles; Stitzel, Joel D; Lang, Jason E
2016-10-26
Femoral head core decompression is an efficacious joint-preserving procedure for treatment of early stage avascular necrosis. However, postoperative fractures have been described which may be related to the decompression technique used. Femoral head decompressions were performed on 12 matched human cadaveric femora comparing large 8mm single bore versus multiple 3mm small drilling techniques. Ultimate failure strength of the femora was tested using a servo-hydraulic material testing system. Ultimate load to failure was compared between the different decompression techniques using two paired ANCOVA linear regression models. Prior to biomechanical testing and after the intervention, volumetric bone mineral density was determined using quantitative computed tomography to account for variation between cadaveric samples and to assess the amount of bone disruption by the core decompression. Core decompression, using the small diameter bore and multiple drilling technique, withstood significantly greater load prior to failure compared with the single large bore technique after adjustment for bone mineral density (p< 0.05). The 8mm single bore technique removed a significantly larger volume of bone compared to the 3mm multiple drilling technique (p< 0.001). However, total fracture energy was similar between the two core decompression techniques. When considering core decompression for the treatment of early stage avascular necrosis, the multiple small bore technique removed less bone volume, thereby potentially leading to higher load to failure.
Sarkar, F H; Valdivieso, M; Borders, J; Yao, K L; Raval, M M; Madan, S K; Sreepathi, P; Shimoyama, R; Steiger, Z; Visscher, D W
1995-12-01
The p53 tumor suppressor gene has been found to be altered in almost all human solid tumors, whereas K-ras gene mutations have been observed in a limited number of human cancers (adenocarcinoma of colon, pancreas, and lung). Studies of mutational inactivation for both genes in the same patient's sample on non-small-cell lung cancer have been limited. In an effort to perform such an analysis, we developed and compared methods (for the mutational detection of p53 and K-ras gene) that represent a modified and universal protocol, in terms of DNA extraction, polymerase chain reaction (PCR) amplification, and nonradioisotopic PCR-single-strand conformation polymorphism (PCR-SSCP) analysis, which is readily applicable to either formalin-fixed, paraffin-embedded tissues or frozen tumor specimens. We applied this method to the evaluation of p53 (exons 5-8) and K-ras (codon 12 and 13) gene mutations in 55 cases of non-small-cell lung cancer. The mutational status in the p53 gene was evaluated by radioisotopic PCR-SSCP and compared with PCR-SSCP utilizing our standardized nonradioisotopic detection system using a single 6-microns tissue section. The mutational patterns observed by PCR-SSCP were subsequently confirmed by PCR-DNA sequencing. The mutational status in the K-ras gene was similarly evaluated by PCR-SSCP, and the specific mutation was confirmed by Southern slot-blot hybridization using 32P-labeled sequence-specific oligonucleotide probes for codons 12 and 13. Mutational changes in K-ras (codon 12) were found in 10 of 55 (18%) of non-small-cell lung cancers. Whereas adenocarcinoma showed K-ras mutation in 33% of the cases at codon 12, only one mutation was found at codon 13. As expected, squamous cell carcinoma samples (25 cases) did not show K-ras mutations. Mutations at exons 5-8 of the p53 gene were documented in 19 of 55 (34.5%) cases. Ten of the 19 mutations were single nucleotide point mutations, leading to amino acid substitution. Six showed insertional mutation, and three showed deletion mutations. Only three samples showed mutations of both K-ras and p53 genes. We conclude that although K-ras and p53 gene mutations are frequent in non-small-cell lung cancer, mutations of both genes in the same patient's samples are not common. We also conclude that this universal nonradioisotopic method is superior to other similar methods and is readily applicable to the rapid screening of large numbers of formalin-fixed, paraffin-embedded or frozen samples for the mutational analysis of multiple genes.
Toward MRI microimaging of single biological cells
NASA Astrophysics Data System (ADS)
Seeber, Derek Allan
There is a great advantage in signal to noise ratio (SNR) that can be obtained in nuclear magnetic resonance (NMR) on very small samples (having spatial dimensions ˜100 mum or less) if one employs NMR "microcoils" that are of similarly small dimensions. These gains in SNR could enable magnetic resonance imaging (MRI) microscopy with spatial resolutions of ˜1--2 mum, much better than currently available. We report the design and testing of a NMR microcoil receiver apparatus, employing solenoidal microcoils of dimensions of tens to hundreds of microns, using an applied field of 9 Tesla (proton frequency 383 MHz). For the smallest receiver coils we attain sensitivity sufficient to observe proton NMR with SNR one in a single scan applied to ˜10 mum3 (10 fl) water sample, containing 7 x 1011 total proton spins. In addition to the NMR applications, microcoils have been applied to MRI producing images with spatial resolutions as low as 2 mum x 3.5 mum x 14.8 mum on phantom images of rods and beads. This resolution can be further improved. MRI imaging of small sample volumes requires significant hardware modifications and improvements, all of which are discussed. Specifically, MRI microscopy requires very strong (>10 T/m), rapidly switchable triaxial magnetic field gradients. We report the design and construction of such a triaxial gradient system, producing gradient substantially greater than 15 T/m in all three directions, x, y, and z (as high as 50 T/m for the x direction). The gradients are power by a custom designed power supply capable of providing currents in excess of 200 amps and switching times of less than 5 mus corresponding to slew rates of greater that 107 T/m/s. The gradients are adequately uniform (within 5% over a volume of 600 mum3) and sufficient for microcoil MRI of small samples.
Fang, Wanping; Meinhardt, Lyndel W; Mischke, Sue; Bellato, Cláudia M; Motilal, Lambert; Zhang, Dapeng
2014-01-15
Cacao (Theobroma cacao L.), the source of cocoa, is an economically important tropical crop. One problem with the premium cacao market is contamination with off-types adulterating raw premium material. Accurate determination of the genetic identity of single cacao beans is essential for ensuring cocoa authentication. Using nanofluidic single nucleotide polymorphism (SNP) genotyping with 48 SNP markers, we generated SNP fingerprints for small quantities of DNA extracted from the seed coat of single cacao beans. On the basis of the SNP profiles, we identified an assumed adulterant variety, which was unambiguously distinguished from the authentic beans by multilocus matching. Assignment tests based on both Bayesian clustering analysis and allele frequency clearly separated all 30 authentic samples from the non-authentic samples. Distance-based principle coordinate analysis further supported these results. The nanofluidic SNP protocol, together with forensic statistical tools, is sufficiently robust to establish authentication and to verify gourmet cacao varieties. This method shows significant potential for practical application.
Atomic force microscopy imaging of macromolecular complexes.
Santos, Sergio; Billingsley, Daniel; Thomson, Neil
2013-01-01
This chapter reviews amplitude modulation (AM) AFM in air and its applications to high-resolution imaging and interpretation of macromolecular complexes. We discuss single DNA molecular imaging and DNA-protein interactions, such as those with topoisomerases and RNA polymerase. We show how relative humidity can have a major influence on resolution and contrast and how it can also affect conformational switching of supercoiled DNA. Four regimes of AFM tip-sample interaction in air are defined and described, and relate to water perturbation and/or intermittent mechanical contact of the tip with either the molecular sample or the surface. Precise control and understanding of the AFM operational parameters is shown to allow the user to switch between these different regimes: an interpretation of the origins of topographical contrast is given for each regime. Perpetual water contact is shown to lead to a high-resolution mode of operation, which we term SASS (small amplitude small set-point) imaging, and which maximizes resolution while greatly decreasing tip and sample wear and any noise due to perturbation of the surface water. Thus, this chapter provides sufficient information to reliably control the AFM in the AM AFM mode of operation in order to image both heterogeneous samples and single macromolecules including complexes, with high resolution and with reproducibility. A brief introduction to AFM, its versatility and applications to biology is also given while providing references to key work and general reviews in the field.
Evaluation of a Dual ALK/ROS1 Fluorescent In Situ Hybridization Test in Non-Small-cell Lung Cancer.
Ginestet, Florent; Lambros, Laetitia; Le Flahec, Glen; Marcorelles, Pascale; Uguen, Arnaud
2018-05-05
Several therapeutics targets have emerged to treat patients with non-small-cell lung carcinoma (NSCLC), with numerous biomarkers available to test for treatment choices. Minimum tumor wastage is necessary to permit the analysis of every potentially relevant target. Searching for targetable ALK and ROS1 rearrangements is now mandatory in NSCLC. In the present study, we evaluated the performance of a dual ALK/ROS1 fluorescent in situ hybridization (FISH) probe that concurrently analyzed the 2 oncogenes on a same FISH slide. We used the FlexISH ALK/ROS1 DistinguISH Probe (Zytovision, Bremerhaven, Germany) to analyze a set of 28 formalin-fixed paraffin-embedded NSCLC tumor samples enriched in tumors with ALK- and ROS1-rearranged status. The dual ALK/ROS1 FISH probe test results were fully concordant with the results of previous single ALK and ROS1 FISH tests (15 ALK and 3 ROS1 rearrangements) without any false-positive results. Dual- and single-probe FISH test results were also concordant regarding the unusual ALK FISH patterns. These included 1 sample that had negative FISH results with diffuse single 5'-ALK signals and positive ALK immunohistochemistry findings in a patient with a response to crizotinib, 2 paired samples with high percentages of ALK FISH-rearranged nuclei despite negative ALK immunohistochemistry findings, and ALK FISH-positive samples from 2 patients lacking a response to crizotinib therapy despite concordant ALK FISH and immunohistochemistry-positive results. The dual ALK/ROS1 FISH probe test is a valuable tool to search concurrently for both ALK and ROS1 rearrangements on a same FISH slide and could help to spare tumor tissue for other biomarkers tests. Copyright © 2018 Elsevier Inc. All rights reserved.
Accuracy of MRI-compatible contrast media injectors.
Saake, M; Wuest, W; Becker, S; Uder, M; Janka, R
2014-03-01
To analyze the exactness of MRI-compatible contrast media (CM) injectors in an experimental setup and clinical use. Ejected fluid volumes and amounts of CM were quantified for single and double piston injections. The focus was on small volumes, as used in pediatric examination and test-bolus measurements. Samples were collected before and after clinical MRI scans and amounts of CM were measured. For single piston injections the volume differences were minimal (mean difference 0.01 ml). For double piston injections the volume of the first injection was decreased (mean 20.74 ml, target 21.00 ml, p < 0.01). After a position change of the Y-piece of the injection system, the amount of CM differed significantly from the target value (mean 1.23 mmol and 0.83 mmol at 1 ml/s flow rate, target 1.00 mmol, p < 0.01), independently of the wait time. The clinical samples confirmed these findings. The pistons of modern CM injectors work exactly. However, for small CM volumes the injected amount of CM can differ significantly from the target value in both directions. Influence factors are an incomplete elimination of air and exchange processes between the CM and saline chaser in the injection system. • In MRI examinations of children and test-bolus measurements, small amounts of CM are used. • The accuracy of single piston injections is high. • In double piston injections the injected amount of CM can differ significantly from the target value. © Georg Thieme Verlag KG Stuttgart · New York.
Thermal hysteresis of the phase-transition temperature of single-crystal GdB6
NASA Astrophysics Data System (ADS)
Reiffers, M.; Ebek, J.; Antavá, E.; Pristá, G.; Kunii, S.
2006-01-01
The phase transition of a single-crystal sample of GdB6, oriented along the 111 axis using the temperature dependence of electrical resistivity (T ), susceptibility (T ) and heat capacity C (T ) under an applied magnetic field was studied. ρ (T ) has shown 2 anomalies - a sharp drop at T N1 = 15.4 K and a small maximum at T N2 = 9.1 K with thermal hysteresis effect. χ (T ) shows the anomalies at both transition temperatures. C (T ) shows similar thermal hysteresis effect at T N2. The small maximum at T N2 decreases its position to lower temperatures with increasing magnetic field. The peak at T N1 is practically unaffected by an applied magnetic field up to 9 T.
Novel and canine genotypes of Giardia duodenalis in harbor seals ( Phoca vitulina richardsi).
Gaydos, J K; Miller, W A; Johnson, C; Zornetzer, H; Melli, A; Packham, A; Jeffries, S J; Lance, M M; Conrad, P A
2008-12-01
Feces of harbor seals (Phoca vitulina richardsi) and hybrid glaucous-winged/western gulls (Larus glaucescens / occidentalis) from Washington State's inland marine waters were examined for Giardia and Cryptosporidium spp. to determine if genotypes carried by these wildlife species were the same genotypes that commonly infect humans and domestic animals. Using immunomagnetic separation followed by direct fluorescent antibody detection, Giardia spp. cysts were detected in 42% of seal fecal samples (41/97). Giardia-positive samples came from 90% of the sites (9/10) and the prevalence of positive seal fecal samples differed significantly among study sites. Fecal samples collected from seal haulout sites with over 400 animals were 4.7 times more likely to have Giardia spp. cysts than samples collected at smaller haulout sites. In gulls, a single Giardia sp. cyst was detected in 4% of fecal samples (3/78). Cryptosporidium spp. oocysts were not detected in any of the seals or gulls tested. Sequence analysis of a 398 bp segment of G. duodenalis DNA at the glutamate dehydrogenase locus suggested that 11 isolates originating from seals throughout the region were a novel genotype and 3 isolates obtained from a single site in south Puget Sound were the G. duodenalis canine genotype D. Real-time TaqMan PCR amplification and subsequent sequencing of a 52 bp small subunit ribosomal DNA region from novel harbor seal genotype isolates showed sequence homology to canine genotypes C and D. Sequence analysis of the 52 bp small subunit ribosomal DNA products from the 3 canine genotype isolates from seals produced mixed sequences at could not be evaluated.
School Composition and Peer Effects in Distinctive Organizational Settings
ERIC Educational Resources Information Center
Marks, Helen M.
2002-01-01
This chapter reviews the research on school composition and peer effects from three comparative perspectives--Catholic and public schools, single-sex and coeducational schools, and small and large schools. Most of the research is sociological, focuses on high schools, and draws on national samples. The chapter seeks to discern cumulative trends in…
McCrae, Robert R.; Scally, Matthew; Terracciano, Antonio; Abecasis, Gonçalo R.; Costa, Paul T.
2011-01-01
There is growing evidence that personality traits are affected by many genes, all of which have very small effects. As an alternative to the largely-unsuccessful search for individual polymorphisms associated with personality traits, we identified large sets of potentially related single nucleotide polymorphisms (SNPs) and summed them to form molecular personality scales (MPSs) with from 4 to 2,497 SNPs. Scales were derived from two-thirds of a large (N = 3,972) sample of individuals from Sardinia who completed the Revised NEO Personality Inventory and were assessed in a genome-wide association scan. When MPSs were correlated with the phenotype in the remaining third of the sample, very small but significant associations were found for four of the five personality factors when the longest scales were examined. These data suggest that MPSs for Neuroticism, Openness to Experience, Agreeableness, and Conscientiousness (but not Extraversion) contain genetic information that can be refined in future studies, and the procedures described here should be applicable to other quantitative traits. PMID:21114353
Global preamplification simplifies targeted mRNA quantification
Kroneis, Thomas; Jonasson, Emma; Andersson, Daniel; Dolatabadi, Soheila; Ståhlberg, Anders
2017-01-01
The need to perform gene expression profiling using next generation sequencing and quantitative real-time PCR (qPCR) on small sample sizes and single cells is rapidly expanding. However, to analyse few molecules, preamplification is required. Here, we studied global and target-specific preamplification using 96 optimised qPCR assays. To evaluate the preamplification strategies, we monitored the reactions in real-time using SYBR Green I detection chemistry followed by melting curve analysis. Next, we compared yield and reproducibility of global preamplification to that of target-specific preamplification by qPCR using the same amount of total RNA. Global preamplification generated 9.3-fold lower yield and 1.6-fold lower reproducibility than target-specific preamplification. However, the performance of global preamplification is sufficient for most downstream applications and offers several advantages over target-specific preamplification. To demonstrate the potential of global preamplification we analysed the expression of 15 genes in 60 single cells. In conclusion, we show that global preamplification simplifies targeted gene expression profiling of small sample sizes by a flexible workflow. We outline the pros and cons for global preamplification compared to target-specific preamplification. PMID:28332609
Genetic characterization of an epidemic of Plasmodium falciparum malaria among Yanomami Amerindians.
Laserson, K F; Petralanda, I; Almera, R; Barker, R H; Spielman, A; Maguire, J H; Wirth, D F
1999-12-01
Malaria parasites are genetically diverse at all levels of endemicity. In contrast, the merozoite surface protein (MSP) alleles in samples from 2 isolated populations of Yanomami Amerindians during an epidemic of Plasmodium falciparum were identical. The nonvariable restriction fragment length polymorphism patterns further suggested that the sequential outbreak comprised only a single P. falciparum genotype. By examination of serial samples from single human infections, the MSP characteristics were found to remain constant throughout the course of infection. An apparent clonal population structure of parasites seemed to cause outbreaks in small isolated villages. The use of standard molecular epidemiologic methods to measure genetic diversity in malaria revealed the occurrence of a genetically monomorphic population of P. falciparum within a human community.
Single point estimation of phenytoin dosing: a reappraisal.
Koup, J R; Gibaldi, M; Godolphin, W
1981-11-01
A previously proposed method for estimation of phenytoin dosing requirement using a single serum sample obtained 24 hours after intravenous loading dose (18 mg/Kg) has been re-evaluated. Using more realistic values for the volume of distribution of phenytoin (0.4 to 1.2 L/Kg), simulations indicate that the proposed method will fail to consistently predict dosage requirements. Additional simulations indicate that two samples obtained during the 24 hour interval following the iv loading dose could be used to more reliably predict phenytoin dose requirement. Because of the nonlinear relationship which exists between phenytoin dose administration rate (RO) and the mean steady state serum concentration (CSS), small errors in prediction of the required RO result in much larger errors in CSS.
Optimization and evaluation of single-cell whole-genome multiple displacement amplification.
Spits, C; Le Caignec, C; De Rycke, M; Van Haute, L; Van Steirteghem, A; Liebaers, I; Sermon, K
2006-05-01
The scarcity of genomic DNA can be a limiting factor in some fields of genetic research. One of the methods developed to overcome this difficulty is whole genome amplification (WGA). Recently, multiple displacement amplification (MDA) has proved very efficient in the WGA of small DNA samples and pools of cells, the reaction being catalyzed by the phi29 or the Bst DNA polymerases. The aim of the present study was to develop a reliable, efficient, and fast protocol for MDA at the single-cell level. We first compared the efficiency of phi29 and Bst polymerases on DNA samples and single cells. The phi29 polymerase generated accurately, in a short time and from a single cell, sufficient DNA for a large set of tests, whereas the Bst enzyme showed a low efficiency and a high error rate. A single-cell protocol was optimized using the phi29 polymerase and was evaluated on 60 single cells; the DNA obtained DNA was assessed by 22 locus-specific PCRs. This new protocol can be useful for many applications involving minute quantities of starting material, such as forensic DNA analysis, prenatal and preimplantation genetic diagnosis, or cancer research. (c) 2006 Wiley-Liss, Inc.
Modeling the genealogy of a cultural trait.
Aguilar, Elliot; Ghirlanda, Stefano
2015-05-01
The mathematical study of genealogies has yielded important insights in population biology, such as the ability to estimate the time to the most recent common ancestor (MRCA) of a sample of genetic sequences or of a group of individuals. Here we introduce a model of cultural genealogies that is a step toward answering similar questions for cultural traits. In our model individuals can inherit from a variable, potentially large number of ancestors, rather than from a fixed, small number of ancestors (one or two) as is typical of genetic evolution. We first show that, given a sample of individuals, a cultural common ancestor does not necessarily exist. We then introduce a related concept: the most recent unique ancestor (MRUA), i.e., the most recent single individual who is the earliest cultural ancestor of the sample. We show that, under neutral evolution, the time to the MRUA can be staggeringly larger than the time to MRCA in a single ancestor model, except when the average number of learning opportunities per individuals is small. Our results point out that the properties of cultural genealogies may be very different from those of genetic genealogies, with potential implications for reconstructing the histories of cultural traits. Copyright © 2014 Elsevier Inc. All rights reserved.
Anderson, Eric C; Ng, Thomas C
2016-02-01
We develop a computational framework for addressing pedigree inference problems using small numbers (80-400) of single nucleotide polymorphisms (SNPs). Our approach relaxes the assumptions, which are commonly made, that sampling is complete with respect to the pedigree and that there is no genotyping error. It relies on representing the inferred pedigree as a factor graph and invoking the Sum-Product algorithm to compute and store quantities that allow the joint probability of the data to be rapidly computed under a large class of rearrangements of the pedigree structure. This allows efficient MCMC sampling over the space of pedigrees, and, hence, Bayesian inference of pedigree structure. In this paper we restrict ourselves to inference of pedigrees without loops using SNPs assumed to be unlinked. We present the methodology in general for multigenerational inference, and we illustrate the method by applying it to the inference of full sibling groups in a large sample (n=1157) of Chinook salmon typed at 95 SNPs. The results show that our method provides a better point estimate and estimate of uncertainty than the currently best-available maximum-likelihood sibling reconstruction method. Extensions of this work to more complex scenarios are briefly discussed. Published by Elsevier Inc.
NASA Technical Reports Server (NTRS)
Thomas, Jr., Jess Brooks (Inventor)
1999-01-01
The front end in GPS receivers has the functions of amplifying, down-converting, filtering and sampling the received signals. In the preferred embodiment, only two operations, A/D conversion and a sum, bring the signal from RF to filtered quadrature baseband samples. After amplification and filtering at RF, the L1 and L2 signals are each sampled at RF at a high selected subharmonic rate. The subharmonic sample rates are approximately 900 MHz for L1 and 982 MHz for L2. With the selected subharmonic sampling, the A/D conversion effectively down-converts the signal from RF to quadrature components at baseband. The resulting sample streams for L1 and L2 are each reduced to a lower rate with a digital filter, which becomes a straight sum in the simplest embodiment. The frequency subsystem can be very simple, only requiring the generation of a single reference frequency (e.g. 20.46 MHz minus a small offset) and the simple multiplication of this reference up to the subharmonic sample rates for L1 and L2. The small offset in the reference frequency serves the dual purpose of providing an advantageous offset in the down-converted carrier frequency and in the final baseband sample rate.
Tung, Yi-Chung; Torisawa, Yu-suke; Futai, Nobuyuki; Takayama, Shuichi
2007-11-01
This paper describes a micro flow cytometer system designed for efficient and non-damaging analysis of samples with small numbers of precious cells. The system utilizes actuation of Braille-display pins for micro-scale fluid manipulation and a fluorescence microscope with a CCD camera for optical detection. The microfluidic chip is fully disposable and is composed of a polydimethylsiloxane (PDMS) slab with microchannel features sealed against a thin deformable PDMS membrane. The channels are designed with diffusers to alleviate pulsatile flow behaviors inherent in pin actuator-based peristaltic pumping schemes to maximize hydrodynamic focusing of samples with minimal disturbances in the laminar streams within the channel. A funnel connected to the microfluidic channel is designed for efficient loading of samples with small number of cells and is also positioned on the chip to prevent physical damages of the samples by the squeezing actions of Braille pins during actuation. The sample loading scheme was characterized by both computational fluidic dynamics (CFD) simulation and experimental observation. A fluorescein solution was first used for flow field investigation, followed by use of fluorescence beads with known relative intensities for optical detection performance calibration. Murine myoblast cells (C2C12) were exploited to investigate cell viability for the sample loading scheme of the device. Furthermore, human promyelocytic leukemia (HL60) cells stained by hypotonic DNA staining buffer were also tested in the system for cell cycle analysis. The ability to efficiently analyze cellular samples where the number of cells is small was demonstrated by analyzing cells from a single embryoid body derived from mouse embryonic stem cells. Consequently, the designed microfluidic device reported in this paper is promising for easy-to-use, small sample size flow cytometric analysis, and has potential to be further integrated with other Braille display-based microfluidic devices to facilitate a multi-functional lab-on-a-chip for mammalian cell manipulations.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rae, Philip J; Bauer, Clare L; Stennett, C
A small scale cook-off experiment has been designed to provide a violence metric for both booster and IHE materials, singly and in combination. The experiment has a simple, axisymmetric geometry provided by a 10 mm internal diameter cylindrical steel confinement up to 80 mm in length. Heating is applied from one end of the sample length creating pseudo 1-D heating profile and a thermal gradient across the sample(s). At the opposite end of the confinement to the heating block, a machined groove provides a point of rupture that generates a cylindrical fragment. The displacement of the external face of themore » fragment is detected by Heterodyne Velocimetry. Proof of concept experiments are reported focusing on HMX and TATB formulations, and are described in relation to confinement, ullage and heating profile. The development of a violence metric, based upon fragment velocity records is discussed.« less
NASA Astrophysics Data System (ADS)
Penttilä, Antti; Maconi, Göran; Kassamakov, Ivan; Gritsevich, Maria; Helander, Petteri; Puranen, Tuomas; Hæggström, Edward; Muinonen, Karri
2017-06-01
We describe a setup for measuring the full angular Mueller matrix profile of a single mm- to μm-sized sample, and verify the experimental results against a theoretical model. The scatterometer has a fixed or levitating sample, illuminated with a laser beam whose full polarization state is controlled. The scattered light is detected with a combination of wave retarder, linear polarizer, and photomultiplier tube that is attached to a rotational stage. The first results are reported.
Optofluidic Cell Selection from Complex Microbial Communities for Single-Genome Analysis
Landry, Zachary C.; Giovanonni, Stephen J.; Quake, Stephen R.; Blainey, Paul C.
2013-01-01
Genetic analysis of single cells is emerging as a powerful approach for studies of heterogeneous cell populations. Indeed, the notion of homogeneous cell populations is receding as approaches to resolve genetic and phenotypic variation between single cells are applied throughout the life sciences. A key step in single-cell genomic analysis today is the physical isolation of individual cells from heterogeneous populations, particularly microbial populations, which often exhibit high diversity. Here, we detail the construction and use of instrumentation for optical trapping inside microfluidic devices to select individual cells for analysis by methods including nucleic acid sequencing. This approach has unique advantages for analyses of rare community members, cells with irregular morphologies, small quantity samples, and studies that employ advanced optical microscopy. PMID:24060116
NASA Astrophysics Data System (ADS)
McEvoy, C. M.; Dufton, P. L.; Evans, C. J.; Kalari, V. M.; Markova, N.; Simón-Díaz, S.; Vink, J. S.; Walborn, N. R.; Crowther, P. A.; de Koter, A.; de Mink, S. E.; Dunstall, P. R.; Hénault-Brunet, V.; Herrero, A.; Langer, N.; Lennon, D. J.; Maíz Apellániz, J.; Najarro, F.; Puls, J.; Sana, H.; Schneider, F. R. N.; Taylor, W. D.
2015-03-01
Context. Model atmosphere analyses have been previously undertaken for both Galactic and extragalactic B-type supergiants. By contrast, little attention has been given to a comparison of the properties of single supergiants and those that are members of multiple systems. Aims: Atmospheric parameters and nitrogen abundances have been estimated for all the B-type supergiants identified in the VLT-FLAMES Tarantula survey. These include both single targets and binary candidates. The results have been analysed to investigate the role of binarity in the evolutionary history of supergiants. Methods: tlusty non-local thermodynamic equilibrium (LTE) model atmosphere calculations have been used to determine atmospheric parameters and nitrogen abundances for 34 single and 18 binary supergiants. Effective temperatures were deduced using the silicon balance technique, complemented by the helium ionisation in the hotter spectra. Surface gravities were estimated using Balmer line profiles and microturbulent velocities deduced using the silicon spectrum. Nitrogen abundances or upper limits were estimated from the N ii spectrum. The effects of a flux contribution from an unseen secondary were considered for the binary sample. Results: We present the first systematic study of the incidence of binarity for a sample of B-type supergiants across the theoretical terminal age main sequence (TAMS). To account for the distribution of effective temperatures of the B-type supergiants it may be necessary to extend the TAMS to lower temperatures. This is also consistent with the derived distribution of mass discrepancies, projected rotational velocities and nitrogen abundances, provided that stars cooler than this temperature are post-red supergiant objects. For all the supergiants in the Tarantula and in a previous FLAMES survey, the majority have small projected rotational velocities. The distribution peaks at about 50 km s-1 with 65% in the range 30 km s-1 ≤ vesini ≤ 60 km s-1. About ten per cent have larger vesini (≥100 km s-1), but surprisingly these show little or no nitrogen enhancement. All the cooler supergiants have low projected rotational velocities of ≤70 km s-1and high nitrogen abundance estimates, implying that either bi-stability braking or evolution on a blue loop may be important. Additionally, there is a lack of cooler binaries, possibly reflecting the small sample sizes. Single-star evolutionary models, which include rotation, can account for all of the nitrogen enhancement in both the single and binary samples. The detailed distribution of nitrogen abundances in the single and binary samples may be different, possibly reflecting differences in their evolutionary history. Conclusions: The first comparative study of single and binary B-type supergiants has revealed that the main sequence may be significantly wider than previously assumed, extending to Teff = 20 000 K. Some marginal differences in single and binary atmospheric parameters and abundances have been identified, possibly implying non-standard evolution for some of the sample. This sample as a whole has implications for several aspects of our understanding of the evolutionary status of blue supergiants. Tables 1, 4, 7 are available in electronic form at http://www.aanda.org
Zhang, Zhen; Wang, Bao-Jie; Guan, Hong-Yu; Pang, Hao; Xuan, Jin-Feng
2009-11-01
Reducing amplicon sizes has become a major strategy for analyzing degraded DNA typical of forensic samples. However, amplicon sizes in current mini-short tandem repeat-polymerase chain reaction (PCR) and mini-sequencing assays are still not suitable for analysis of severely degraded DNA. In this study, we present a multiplex typing method that couples ligase detection reaction with PCR that can be used to identify single nucleotide polymorphisms and small-scale insertion/deletions in a sample of severely fragmented DNA. This method adopts thermostable ligation for allele discrimination and subsequent PCR for signal enhancement. In this study, four polymorphic loci were used to assess the ability of this technique to discriminate alleles in an artificially degraded sample of DNA with fragment sizes <100 bp. Our results showed clear allelic discrimination of single or multiple loci, suggesting that this method might aid in the analysis of extremely degraded samples in which allelic drop out of larger fragments is observed.
Register, Janna; Scaffidi, Jonathan; Angel, S Michael
2012-08-01
Direct measurements of temperature changes were made using small thermocouples (TC), placed near a laser-induced air plasma. Temperature changes up to ~500 °C were observed. From the measured temperature changes, estimates were made of the amount of heat absorbed per unit area. This allowed calculations to be made of the surface temperature, as a function of time, of a sample heated by the air plasma that is generated during orthogonal pre-ablation spark dual-pulse (DP) LIBS measurements. In separate experiments, single-pulse (SP) LIBS emission and sample ablation rate measurements were performed on nickel at sample temperatures ranging from room temperature to the maximum surface temperature that was calculated using the TC measurement results (500 °C). A small, but real sample temperature-dependent increase in both SP LIBS emission and the rate of sample ablation was found for nickel samples heated up to 500 °C. Comparison of DP LIBS emission enhancement values for bulk nickel samples at room temperature versus the enhanced SP LIBS emission and sample ablation rates observed as a function of increasing sample temperature suggests that sample heating by the laser-induced air plasma plays only a minor role in DP LIBS emission enhancement.
Impact of sampling techniques on measured stormwater quality data for small streams
Harmel, R.D.; Slade, R.M.; Haney, R.L.
2010-01-01
Science-based sampling methodologies are needed to enhance water quality characterization for setting appropriate water quality standards, developing Total Maximum Daily Loads, and managing nonpoint source pollution. Storm event sampling, which is vital for adequate assessment of water quality in small (wadeable) streams, is typically conducted by manual grab or integrated sampling or with an automated sampler. Although it is typically assumed that samples from a single point adequately represent mean cross-sectional concentrations, especially for dissolved constituents, this assumption of well-mixed conditions has received limited evaluation. Similarly, the impact of temporal (within-storm) concentration variability is rarely considered. Therefore, this study evaluated differences in stormwater quality measured in small streams with several common sampling techniques, which in essence evaluated within-channel and within-storm concentration variability. Constituent concentrations from manual grab samples and from integrated samples were compared for 31 events, then concentrations were also compared for seven events with automated sample collection. Comparison of sampling techniques indicated varying degrees of concentration variability within channel cross sections for both dissolved and particulate constituents, which is contrary to common assumptions of substantial variability in particulate concentrations and of minimal variability in dissolved concentrations. Results also indicated the potential for substantial within-storm (temporal) concentration variability for both dissolved and particulate constituents. Thus, failing to account for potential cross-sectional and temporal concentration variability in stormwater monitoring projects can introduce additional uncertainty in measured water quality data. Copyright ?? 2010 by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America. All rights reserved.
Repeated sampling of genes from a single cell - implications for gravitropism research
NASA Astrophysics Data System (ADS)
Scherp, P.; Hasenstein, K. H.
The need for repeated but independent extractions of mRNA from single cells and plant tissues prompted the development of Solid Phase Gene Extraction (SPGE, patent pending). Oligo dT18 coated glass needles hybridize during a 2 to 3 min sampling time with the poly A+ mRNA. The needle is withdrawn and can be used directly for RT-PCR. Because of the small probe size, no cytoplasm is lost and repeated sampling of the same cell is possible. SPGE of Chara rhizoids and internodal cells showed fluctuations of type and quantity of mRNA in specific areas of the cytoplasm of rhizoids and time-dependent gene expression in internodal cells as a function of light/dark intervals. Despite extensive cytoplasmic streaming, mRNA-samples taken in the vicinity of the nucleus revealed a higher variability than the distal ends of the cell. In rhizoids, the mRNA/cDNA varied between the different zones of cytoplasm. In Arabidopsis, we isolated cDNA species from root tips, shoots and leaves and determined their sequences. Growth studies on SPGE-sampled individuals showed that after a short recovery period, all sampled plants resumed growth with normal growth rates and graviresponse. The data indicate that SPGE is a powerful method to study gene expression in single cells and in tissues of higher plants with high spatial and temporal resolution. Supported by NASA: NAG 2-1423
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hardcastle, Nicholas; Bayliss, Adam; Wong, Jeannie Hsiu Ding
2012-08-15
Purpose: A recent field safety notice from TomoTherapy detailed the underdosing of small, off-axis targets when receiving high doses per fraction. This is due to angular undersampling in the dose calculation gantry angles. This study evaluates a correction method to reduce the underdosing, to be implemented in the current version (v4.1) of the TomoTherapy treatment planning software. Methods: The correction method, termed 'Super Sampling' involved the tripling of the number of gantry angles from which the dose is calculated during optimization and dose calculation. Radiochromic film was used to measure the dose to small targets at various off-axis distances receivingmore » a minimum of 21 Gy in one fraction. Measurements were also performed for single small targets at the center of the Lucy phantom, using radiochromic film and the dose magnifying glass (DMG). Results: Without super sampling, the peak dose deficit increased from 0% to 18% for a 10 mm target and 0% to 30% for a 5 mm target as off-axis target distances increased from 0 to 16.5 cm. When super sampling was turned on, the dose deficit trend was removed and all peak doses were within 5% of the planned dose. For measurements in the Lucy phantom at 9.7 cm off-axis, the positional and dose magnitude accuracy using super sampling was verified using radiochromic film and the DMG. Conclusions: A correction method implemented in the TomoTherapy treatment planning system which triples the angular sampling of the gantry angles used during optimization and dose calculation removes the underdosing for targets as small as 5 mm diameter, up to 16.5 cm off-axis receiving up to 21 Gy.« less
Llop, Pablo; Bonaterra, Anna; Peñalver, Javier; López, María M.
2000-01-01
A novel method, which involves a nested PCR in a single closed tube, was developed for the sensitive detection of Erwinia amylovora in plant material. The external and internal primer pairs used had different annealing temperatures and directed the amplification of a specific DNA fragment from plasmid pEA29. The procedure involved two consecutive PCRs, the first of which was performed at a higher annealing temperature that allowed amplification only by the external primer pair. Using pure cultures of E. amylovora, the sensitivity of the nested PCR in one tube was similar to that of a standard nested PCR in two tubes. The specificity and sensitivity were greater than those of standard PCR procedures that used a single primer pair. The presence of inhibitors in plant material, very common in E. amylovora hosts, is overcome with this system in combination with a simple DNA extraction protocol because it eliminates many of the inhibitory compounds. In addition, it needs a very small sample volume (1 μl of DNA extracted). With 83 samples of naturally infected material, this method achieved better results than any other PCR technique: standard PCR detected 55% of positive samples, two-tube nested PCR detected 71% of positive samples, and nested PCR in a single closed tube detected 78% of positive samples. When analyzing asymptomatic plant material, the number of positive samples detected by the developed nested PCR was also the highest, compared with the PCR protocols indicated previously (17, 20, and 25% of 251 samples analyzed, respectively). This method is proposed for the detection of endophytic and epiphytic populations of E. amylovora in epidemiological studies and for routine use in quarantine surveys, due to its high sensitivity, specificity, speed, and simplicity. PMID:10788384
Effects of Coatings on the High-Cycle Fatigue Life of Threaded Steel Samples
NASA Astrophysics Data System (ADS)
Eder, M. A.; Haselbach, P. U.; Mishin, O. V.
2018-05-01
In this work, high-cycle fatigue is studied for threaded cylindrical high-strength steel samples coated using three different industrial processes: black oxidation, normal-temperature galvanization and high-temperature galvanization. The fatigue performance in air is compared with that of uncoated samples. Microstructural characterization revealed the abundant presence of small cracks in the zinc coating partially penetrating into the steel. This is consistent with the observation of multiple crack initiation sites along the thread in the galvanized samples, which led to crescent type fracture surfaces governed by circumferential growth. In contrast, the black oxidized and uncoated samples exhibited a semicircular segment type fracture surface governed by single-sided growth with a significantly longer fatigue life. Numerical fatigue life prediction based on an extended Paris-law formulation has been conducted on two different fracture cases: 2D axisymmetric multisided crack growth and 3D single-sided crack growth. The results of this upper-bound and lower-bound approach are in good agreement with experimental data and can potentially be used to predict the lifetime of bolted components.
Lentic small water bodies: Variability of pesticide transport and transformation patterns.
Ulrich, Uta; Hörmann, Georg; Unger, Malte; Pfannerstill, Matthias; Steinmann, Frank; Fohrer, Nicola
2018-03-15
Lentic small water bodies have a high ecological potential as they fulfill several ecosystem services such as the retention of water and pollutants. They serve as a hot spot of biodiversity. Due to their location in or adjacent to agricultural fields, they can be influenced by inputs of pesticides and their transformation products. Since small water bodies have rarely been part of monitorings/campaigns up to now, their current exposure and processes guiding the pesticide input are not understood, yet. This study presents results of a sampling campaign of 10 lentic small water bodies from 2015 to 2016. They were sampled once after the spring application for a pesticide target screening, before autumn application and three times after rainfall events following the application. The autumn sampling focused on the herbicides metazachlor, flufenacet and their transformation products - oxalic acid and - sulfonic acid as representatives for common pesticides in the study region. The concentrations were associated with rainfall before and after application, characteristics of the site and the water bodies, physicochemical parameters and the applied amount of pesticides. The key results of the pesticide screening in spring indicate positive detections of pesticides which have not been applied for years to the single fields. The autumn sampling showed frequent occurrences of the transformation products, which are formed in soil, from 39% to 94% of all samples (n=71). Discharge patterns were observed for metazachlor with highest concentrations in the first sample after application and then decreasing, but not for flufenacet. The concentrations of the transformation products increased over time and revealed highest values mainly in the last sample. Besides rainfall patterns right after application, the spatial and temporal dissemination of the pesticides to the water bodies seems to play a major role to understand the exposure of lentic small water bodies. Copyright © 2017 Elsevier B.V. All rights reserved.
Good performance of an immunoassay based method for nevirapine measurements in human breast milk.
Salado-Rasmussen, Kirsten; Theilgaard, Zahra Persson; Chiduo, Mercy; Pedersen, Court; Gerstoft, Jan; Katzenstein, Terese Lea
2011-07-01
Understanding the distribution of antiretro-virals in breastfeeding HIV-positive mothers is essential, both for prevention of mother-to-child HIV transmission and for research on the development of drug resistance. The ARK nevirapine (NVP)-test is an immunoassay method for nevirapine measurements, developed and validated for plasma use. In this study, the ARK NVP-test was evaluated for measurement of nevirapine concentrations in breast milk. High performance liquid chromatography (HPLC) is the method currently used to determine nevirapine in breast milk. This method, however, requires complicated extraction techniques. The ARK method employs an immunoassay technology and requires a small sample volume (40 μL) and no pre-treatment of the samples. Commercial enzyme and antibody were used and calibration standards and quality controls were prepared from pooled breast milk from HIV-uninfected women. Clinical samples from HIV-infected women receiving a single-dose of nevirapine were analyzed. Precision and accuracy were evaluated with two concentrations of quality control materials analyzed in three replicates on four different days and was <4%, and between 96.5% and 104.6%, respectively. Clinical samples were analyzed and CVs ranged from 0.0% to 11.1%. The median nevirapine concentration in breast milk 1 week post-partum was 0.29 μg/mL (range 0.11-0.90 μg/mL) in women treated with a single-dose of nevirapine. The ease of use and small sample volume makes the ARK assay an attractive alternative to HPLC analyses for determinations of nevirapine concentrations in breast milk.
Concentration methods for high-resolution THz spectroscopy of nucleic-acid biomolecules and crystals
NASA Astrophysics Data System (ADS)
Brown, E. R.; Zhang, W.; Mendoza, E. A.; Kuznetsova, Y.; Brueck, S. R. J.; Rahman, M.; Norton, M. L.
2012-03-01
Biomolecules can exhibit low-lying vibrational modes in the THz region which are detectable in transmission given a strong molecular dipole moment and optical depth, and a spectrometer of adequate sensitivity. The nucleic acids are particularly interesting because of applications such as label-free gene assay, bio-agent detection, etc. However for nucleic acids, sample preparation and THz coupling are of paramount importance because of the strong absorption by liquid water and the small concentration of molecules present in physiological solutions. Concentration methods become necessary to make the THz vibrational modes detectable, either by concentrating the nucleic-acid sample itself in a small volume but large area, or by concentrating the THz radiation down to the volume of the sample. This paper summarizes one type of the first method: nanofluidic channel arrays for biological nucleic acids; and two types of the second method: (1) a circular-waveguide pinhole, and (2) a circular-waveguide, conical-horn coupling structure, both for DNA crystals. The first method has been demonstrated on a very short artificial nucleic acid [small-interfering (si) RNA (17-to-25 bp)] and a much longer, biological molecule [Lambda-phage DNA (48.5 kbp)]. The second method has been demonstrated on small (~100 micron) single crystals of DNA grown by the sitting-drop method.
Near bed suspended sediment flux by single turbulent events
NASA Astrophysics Data System (ADS)
Amirshahi, Seyed Mohammad; Kwoll, Eva; Winter, Christian
2018-01-01
The role of small scale single turbulent events in the vertical mixing of near bed suspended sediments was explored in a shallow shelf sea environment. High frequency velocity and suspended sediment concentration (SSC; calibrated from the backscatter intensity) were collected using an Acoustic Doppler Velocimeter (ADV). Using quadrant analysis, the despiked velocity time series was divided into turbulent events and small background fluctuations. Reynolds stress and Turbulent Kinetic Energy (TKE) calculated from all velocity samples, were compared to the same turbulent statistics calculated only from velocity samples classified as turbulent events (Reevents and TKEevents). The comparison showed that Reevents and TKEevents was increased 3 and 1.6 times, respectively, when small background fluctuations were removed and that the correlation with SSC for TKE could be improved through removal of the latter. The correlation between instantaneous vertical turbulent flux (w ‧) and SSC fluctuations (SSC ‧) exhibits a tidal pattern with the maximum correlation at peak ebb and flood currents, when strong turbulent events appear. Individual turbulent events were characterized by type, strength, duration and length. Cumulative vertical turbulent sediment fluxes and average SSC associated with individual turbulent events were calculated. Over the tidal cycle, ejections and sweeps were the most dominant events, transporting 50% and 36% of the cumulative vertical turbulent event sediment flux, respectively. Although the contribution of outward interactions to the vertical turbulent event sediment flux was low (11%), single outward interaction events were capable of inducing similar SSC ‧ as sweep events. The results suggest that on time scales of tens of minutes to hours, TKE may be appropriate to quantify turbulence in sediment transport studies, but that event characteristics, particular the upward turbulent flux need to be accounted for when considering sediment transport on process time scales.
Dual echelon femtosecond single-shot spectroscopy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shin, Taeho; Wolfson, Johanna W.; Teitelbaum, Samuel W.
We have developed a femtosecond single-shot spectroscopic technique to measure irreversible changes in condensed phase materials in real time. Crossed echelons generate a two-dimensional array of time-delayed pulses with one femtosecond probe pulse. This yields 9 ps of time-resolved data from a single laser shot, filling a gap in currently employed measurement methods. We can now monitor ultrafast irreversible dynamics in solid-state materials or other samples that cannot be flowed or replenished between laser shots, circumventing limitations of conventional pump-probe methods due to sample damage or product buildup. Despite the absence of signal-averaging in the single-shot measurement, an acceptable signal-to-noisemore » level has been achieved via background and reference calibration procedures. Pump-induced changes in relative reflectivity as small as 0.2%−0.5% are demonstrated in semimetals, with both electronic and coherent phonon dynamics revealed by the data. The optical arrangement and the space-to-time conversion and calibration procedures necessary to achieve this level of operation are described. Sources of noise and approaches for dealing with them are discussed.« less
Leung, Kaston; Klaus, Anders; Lin, Bill K; Laks, Emma; Biele, Justina; Lai, Daniel; Bashashati, Ali; Huang, Yi-Fei; Aniba, Radhouane; Moksa, Michelle; Steif, Adi; Mes-Masson, Anne-Marie; Hirst, Martin; Shah, Sohrab P; Aparicio, Samuel; Hansen, Carl L
2016-07-26
The genomes of large numbers of single cells must be sequenced to further understanding of the biological significance of genomic heterogeneity in complex systems. Whole genome amplification (WGA) of single cells is generally the first step in such studies, but is prone to nonuniformity that can compromise genomic measurement accuracy. Despite recent advances, robust performance in high-throughput single-cell WGA remains elusive. Here, we introduce droplet multiple displacement amplification (MDA), a method that uses commercially available liquid dispensing to perform high-throughput single-cell MDA in nanoliter volumes. The performance of droplet MDA is characterized using a large dataset of 129 normal diploid cells, and is shown to exceed previously reported single-cell WGA methods in amplification uniformity, genome coverage, and/or robustness. We achieve up to 80% coverage of a single-cell genome at 5× sequencing depth, and demonstrate excellent single-nucleotide variant (SNV) detection using targeted sequencing of droplet MDA product to achieve a median allelic dropout of 15%, and using whole genome sequencing to achieve false and true positive rates of 9.66 × 10(-6) and 68.8%, respectively, in a G1-phase cell. We further show that droplet MDA allows for the detection of copy number variants (CNVs) as small as 30 kb in single cells of an ovarian cancer cell line and as small as 9 Mb in two high-grade serous ovarian cancer samples using only 0.02× depth. Droplet MDA provides an accessible and scalable method for performing robust and accurate CNV and SNV measurements on large numbers of single cells.
NASA Astrophysics Data System (ADS)
Cesar, D.; Maxson, J.; Musumeci, P.; Sun, Y.; Harrison, J.; Frigola, P.; O'Shea, F. H.; To, H.; Alesini, D.; Li, R. K.
2016-07-01
We present the results of an experiment where a short focal length (˜1.3 cm ), permanent magnet electron lens is used to image micron-size features (of a metal sample) with a single shot from an ultrahigh brightness picosecond-long 4 MeV electron beam emitted by a radio-frequency photoinjector. Magnification ratios in excess of 30 × were obtained using a triplet of compact, small gap (3.5 mm), Halbach-style permanent magnet quadrupoles with nearly 600 T /m field gradients. These results pave the way towards single-shot time-resolved electron microscopy and open new opportunities in the applications of high brightness electron beams.
Marciani, L; Garsed, K C; Hoad, C L; Fields, A; Fordham, I; Pritchard, S E; Placidi, E; Murray, K; Chaddock, G; Costigan, C; Lam, C; Jalanka-Tuovinen, J; De Vos, W M; Gowland, P A; Spiller, R C
2014-01-01
Background Most methods of assessing colonic motility are poorly acceptable to patients. Magnetic resonance imaging (MRI) can monitor gastrointestinal motility and fluid distributions. We predicted that a dose of oral polyethylene glycol (PEG) and electrolyte solution would increase ileo-colonic inflow and stimulate colonic motility. We aimed to investigate the colonic response to distension by oral PEG electrolyte in healthy volunteers (HVs) and to evaluate the effect of single 2 L vs split (2 × 1 L) dosing. Methods Twelve HVs received a split dose (1 L the evening before and 1 L on the study day) and another 12 HVs a single dose (2 L on the main study day) of PEG electrolyte. They underwent MRI scans, completed symptom questionnaires, and provided stool samples. Outcomes included small bowel water content, ascending colon motility index, and regional colonic volumes. Key Results Small bowel water content increased fourfold from baseline after ingesting both split (p = 0.0010) and single dose (p = 0.0005). The total colonic volume increase from baseline was smaller for the split dose at 35 ± 8% than for the single dose at 102 ± 27%, p = 0.0332. The ascending colon motility index after treatment was twofold higher for the single dose group (p = 0.0103). Conclusions & Inferences Ingestion of 1 and 2 L PEG electrolyte solution caused a rapid increase in the small bowel and colonic volumes and a robust rise in colonic motility. The increase in both volumes and motility was dose dependent. Such a challenge, being well-tolerated, could be a useful way of assessing colonic motility in future studies. PMID:25060551
DOE-2 sample run book: Version 2.1E
DOE Office of Scientific and Technical Information (OSTI.GOV)
Winkelmann, F.C.; Birdsall, B.E.; Buhl, W.F.
1993-11-01
The DOE-2 Sample Run Book shows inputs and outputs for a variety of building and system types. The samples start with a simple structure and continue to a high-rise office building, a medical building, three small office buildings, a bar/lounge, a single-family residence, a small office building with daylighting, a single family residence with an attached sunspace, a ``parameterized`` building using input macros, and a metric input/output example. All of the samples use Chicago TRY weather. The main purpose of the Sample Run Book is instructional. It shows the relationship of LOADS-SYSTEMS-PLANT-ECONOMICS inputs, displays various input styles, and illustrates manymore » of the basic and advanced features of the program. Many of the sample runs are preceded by a sketch of the building showing its general appearance and the zoning used in the input. In some cases we also show a 3-D rendering of the building as produced by the program DrawBDL. Descriptive material has been added as comments in the input itself. We find that a number of users have loaded these samples onto their editing systems and use them as ``templates`` for creating new inputs. Another way of using them would be to store various portions as files that can be read into the input using the {number_sign}{number_sign} include command, which is part of the Input Macro feature introduced in version DOE-2.lD. Note that the energy rate structures here are the same as in the DOE-2.lD samples, but have been rewritten using the new DOE-2.lE commands and keywords for ECONOMICS. The samples contained in this report are the same as those found on the DOE-2 release files. However, the output numbers that appear here may differ slightly from those obtained from the release files. The output on the release files can be used as a check set to compare results on your computer.« less
Small-Chamber Measurements of Chemical-Specific Emission Factors for Drywall
DOE Office of Scientific and Technical Information (OSTI.GOV)
Maddalena, Randy; Russell, Marion; Apte, Michael G.
2010-06-01
Imported drywall installed in U.S. homes is suspected of being a source of odorous and potentially corrosive indoor pollutants. To support an investigation of those building materials by the Consumer Products Safety Commission (CPSC), Lawrence Berkeley National Laboratory (LBNL) measured chemical-specific emission factors for 30 samples of drywall materials. Emission factors are reported for 75 chemicals and 30 different drywall samples encompassing both domestic and imported stock and incorporating natural, synthetic, or mixed gypsum core material. CPSC supplied all drywall materials. First the drywall samples were isolated and conditioned in dedicated chambers, then they were transferred to small chambers wheremore » emission testing was performed. Four sampling and analysis methods were utilized to assess (1) volatile organic compounds, (2) low molecular weight carbonyls, (3) volatile sulfur compounds, and (4) reactive sulfur gases. LBNL developed a new method that combines the use of solid phase microextraction (SPME) with small emission chambers to measure the reactive sulfur gases, then extended that technique to measure the full suite of volatile sulfur compounds. The testing procedure and analysis methods are described in detail herein. Emission factors were measured under a single set of controlled environmental conditions. The results are compared graphically for each method and in detailed tables for use in estimating indoor exposure concentrations.« less
Green, Michael V; Seidel, Jurgen; Choyke, Peter L; Jagoda, Elaine M
2017-10-01
We describe a simple fixture that can be added to the imaging bed of a small-animal PET scanner that allows for automated counting of multiple organ or tissue samples from mouse-sized animals and counting of injection syringes prior to administration of the radiotracer. The combination of imaging and counting capabilities in the same machine offers advantages in certain experimental settings. A polyethylene block of plastic, sculpted to mate with the animal imaging bed of a small-animal PET scanner, is machined to receive twelve 5-ml containers, each capable of holding an entire organ from a mouse-sized animal. In addition, a triangular cross-section slot is machined down the centerline of the block to secure injection syringes from 1-ml to 3-ml in size. The sample holder is scanned in PET whole-body mode to image all samples or in one bed position to image a filled injection syringe. Total radioactivity in each sample or syringe is determined from the reconstructed images of these objects using volume re-projection of the coronal images and a single region-of-interest for each. We tested the accuracy of this method by comparing PET estimates of sample and syringe activity with well counter and dose calibrator estimates of these same activities. PET and well counting of the same samples gave near identical results (in MBq, R 2 =0.99, slope=0.99, intercept=0.00-MBq). PET syringe and dose calibrator measurements of syringe activity in MBq were also similar (R 2 =0.99, slope=0.99, intercept=- 0.22-MBq). A small-animal PET scanner can be easily converted into a multi-sample and syringe counting device by the addition of a sample block constructed for that purpose. This capability, combined with live animal imaging, can improve efficiency and flexibility in certain experimental settings. Copyright © 2017 Elsevier Inc. All rights reserved.
miRge - A Multiplexed Method of Processing Small RNA-Seq Data to Determine MicroRNA Entropy
Myers, Jason R.; Gupta, Simone; Weng, Lien-Chun; Ashton, John M.; Cornish, Toby C.; Pandey, Akhilesh; Halushka, Marc K.
2015-01-01
Small RNA RNA-seq for microRNAs (miRNAs) is a rapidly developing field where opportunities still exist to create better bioinformatics tools to process these large datasets and generate new, useful analyses. We built miRge to be a fast, smart small RNA-seq solution to process samples in a highly multiplexed fashion. miRge employs a Bayesian alignment approach, whereby reads are sequentially aligned against customized mature miRNA, hairpin miRNA, noncoding RNA and mRNA sequence libraries. miRNAs are summarized at the level of raw reads in addition to reads per million (RPM). Reads for all other RNA species (tRNA, rRNA, snoRNA, mRNA) are provided, which is useful for identifying potential contaminants and optimizing small RNA purification strategies. miRge was designed to optimally identify miRNA isomiRs and employs an entropy based statistical measurement to identify differential production of isomiRs. This allowed us to identify decreasing entropy in isomiRs as stem cells mature into retinal pigment epithelial cells. Conversely, we show that pancreatic tumor miRNAs have similar entropy to matched normal pancreatic tissues. In a head-to-head comparison with other miRNA analysis tools (miRExpress 2.0, sRNAbench, omiRAs, miRDeep2, Chimira, UEA small RNA Workbench), miRge was faster (4 to 32-fold) and was among the top-two methods in maximally aligning miRNAs reads per sample. Moreover, miRge has no inherent limits to its multiplexing. miRge was capable of simultaneously analyzing 100 small RNA-Seq samples in 52 minutes, providing an integrated analysis of miRNA expression across all samples. As miRge was designed for analysis of single as well as multiple samples, miRge is an ideal tool for high and low-throughput users. miRge is freely available at http://atlas.pathology.jhu.edu/baras/miRge.html. PMID:26571139
Growth and characterization of CaFe1-xCoxAsF single crystals by CaAs flux method
NASA Astrophysics Data System (ADS)
Ma, Yonghui; Hu, Kangkang; Ji, Qiucheng; Gao, Bo; Zhang, Hui; Mu, Gang; Huang, Fuqiang; Xie, Xiaoming
2016-10-01
Millimeter sized single crystals of CaFe1-x Cox AsF were grown using a self-flux method. It is found that high-quality single crystals can be grown from three approaches with different initial raw materials. The chemical compositions and crystal structure were characterized carefully. Compared with the undoped parent phase CaFeAsF, the crystal lattice along the c-axis is suppressed by the Co substitution while that along the a-axis expands slightly. Superconductivity with the critical transition Tc as high as 21 K was confirmed by both the resistivity and magnetic susceptibility measurements in the sample with x=0.118. Moreover, it is found that Tc can be enhanced for about 1 K under the very small hydrostatic pressure of 0.22 GPa, which is more quick than that reported in the polycrystalline samples. Our results are a promotion for the physical investigations of 1111 phase iron-pnictide superconductors.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Boedicker, J.; Li, L; Kline, T
2008-01-01
This article describes plug-based microfluidic technology that enables rapid detection and drug susceptibility screening of bacteria in samples, including complex biological matrices, without pre-incubation. Unlike conventional bacterial culture and detection methods, which rely on incubation of a sample to increase the concentration of bacteria to detectable levels, this method confines individual bacteria into droplets nanoliters in volume. When single cells are confined into plugs of small volume such that the loading is less than one bacterium per plug, the detection time is proportional to plug volume. Confinement increases cell density and allows released molecules to accumulate around the cell, eliminatingmore » the pre-incubation step and reducing the time required to detect the bacteria. We refer to this approach as stochastic confinement. Using the microfluidic hybrid method, this technology was used to determine the antibiogram - or chart of antibiotic sensitivity - of methicillin-resistant Staphylococcus aureus (MRSA) to many antibiotics in a single experiment and to measure the minimal inhibitory concentration (MIC) of the drug cefoxitin (CFX) against this strain. In addition, this technology was used to distinguish between sensitive and resistant strains of S. aureus in samples of human blood plasma. High-throughput microfluidic techniques combined with single-cell measurements also enable multiple tests to be performed simultaneously on a single sample containing bacteria. This technology may provide a method of rapid and effective patient-specific treatment of bacterial infections and could be extended to a variety of applications that require multiple functional tests of bacterial samples on reduced timescales.« less
A multi-staining chip using hydrophobic valves for exfoliative cytology in cancer
NASA Astrophysics Data System (ADS)
Lee, Tae Hee; Bu, Jiyoon; Moon, Jung Eun; Kim, Young Jun; Kang, Yoon-Tae; Cho, Young-Ho; Kim, In Sik
2017-07-01
Exfoliative cytology is a highly established technique for the diagnosis of tumors. Various microfluidic devices have been developed to minimize the sample numbers by conjugating multiple antibodies in a single sample. However, the previous multi-staining devices require complex control lines and valves operated by external power sources, to deliver multiple antibodies separately for a single sample. In addition, most of these devices are composed of hydrophobic materials, causing unreliable results due to the non-specific binding of antibodies. Here, we present a multi-staining chip using hydrophobic valves, which is formed by the partial treatment of 2-hydroxyethyl methacrylate (HEMA). Our chip consists of a circular chamber, divided into six equal fan-shaped regions. Switchable injection ports are located at the center of the chamber and at the middle of the arc of each fan-shaped zone. Thus, our device is beneficial for minimizing the control lines, since pre-treatment solutions flow from the center to outer ports, while six different antibodies are introduced oppositely from the outer ports. Furthermore, hydrophobic narrow channels, connecting the central region and each of the six fan-shaped zones, are closed by capillary effect, thus preventing the fluidic mixing without external power sources. Meanwhile, HEMA treatment on the exterior region results in hydrophobic-to-hydrophilic transition and prevents the non-specific binding of antibodies. For the application, we measured the expression of six different antibodies in a single sample using our device. The expression levels of each antibody highly matched the conventional immunocytochemistry results. Our device enables cancer screening with a small number of antibodies for a single sample.
Impact of stand diameter and product markets on revenue gains from multiproduct harvesting
John E. Baumgras; Chris B. LeDoux
1988-01-01
Data from 113 sample thinning plots and a microcomputer program called APTHIN were used to demonstrate the impact of mean stand diameter and product markets on revenue gains from multiproduct versus single-product pulpwood harvests in poletimber and small sawtimber stands of Appalachian hardwoods. The analysis of revenue gains included product mix as a function of the...
McCrae, Robert R; Scally, Matthew; Terracciano, Antonio; Abecasis, Gonçalo R; Costa, Paul T
2010-12-01
There is growing evidence that personality traits are affected by many genes, all of which have very small effects. As an alternative to the largely unsuccessful search for individual polymorphisms associated with personality traits, the authors identified large sets of potentially related single nucleotide polymorphisms (SNPs) and summed them to form molecular personality scales (MPSs) with from 4 to 2,497 SNPs. Scales were derived from two thirds of a large (N = 3,972) sample of individuals from Sardinia who completed the Revised NEO Personality Inventory (P. T. Costa, Jr., & R. R. McCrae, 1992) and were assessed in a genomewide association scan. When MPSs were correlated with the phenotype in the remaining one third of the sample, very small but significant associations were found for 4 of the 5e personality factors when the longest scales were examined. These data suggest that MPSs for Neuroticism, Openness to Experience, Agreeableness, and Conscientiousness (but not Extraversion) contain genetic information that can be refined in future studies, and the procedures described here should be applicable to other quantitative traits. PsycINFO Database Record (c) 2010 APA, all rights reserved.
Tang, Hao; Hiemstra, Scott; Thompson, Jonathan E
2011-09-19
An approach to sample and analyze single aerosolized droplets (<10 nL) of solutions containing fluorescein isothiocyanate (FITC) labeled glycine (GLY) and glutamic acid (GLU) is demonstrated. The sampling approach is based on inertial impaction in which the sample particle is accelerated through a nozzle and directly into a small drop of buffered solution (20 mM borate, pH=10) suspended at the end of a coaxial tube of stainless steel and a fused silica capillary. A spherical light scattering cell and laser (λ=532 nm) is used to detect the arrival of particles at the buffered droplet. Upon dissolution and/or mixing, a portion of the sample is injected onto the fused silica capillary for subsequent chemical analysis by capillary electrophoresis (CE) and detection by laser-induced fluorescence (LIF). It was found that the inertial impaction approach sampled particles >1 μm diameter with an efficiency of 80% or greater. At 15 kV applied potential, the FITC conjugates of GLY and GLU could be resolved in less than 120 s allowing qualitative analysis of the contents of single dispersed particles. However, the extent to which the sample is diluted into the buffer droplet varied significantly on a per-particle basis that caused >80% R.S.D. in fluorescence peak heights. This aspect of the method would necessitate the use of internal standards for quantitative analysis of materials present within the particles. It is envisaged that further improvements to the device described may ultimately lead to analysis of the contents of single particles dispersed in earth's atmosphere. Copyright © 2011 Elsevier B.V. All rights reserved.
Indirect estimation of signal-dependent noise with nonadaptive heterogeneous samples.
Azzari, Lucio; Foi, Alessandro
2014-08-01
We consider the estimation of signal-dependent noise from a single image. Unlike conventional algorithms that build a scatterplot of local mean-variance pairs from either small or adaptively selected homogeneous data samples, our proposed approach relies on arbitrarily large patches of heterogeneous data extracted at random from the image. We demonstrate the feasibility of our approach through an extensive theoretical analysis based on mixture of Gaussian distributions. A prototype algorithm is also developed in order to validate the approach on simulated data as well as on real camera raw images.
High-resolution, high-throughput imaging with a multibeam scanning electron microscope
EBERLE, AL; MIKULA, S; SCHALEK, R; LICHTMAN, J; TATE, ML KNOTHE; ZEIDLER, D
2015-01-01
Electron–electron interactions and detector bandwidth limit the maximal imaging speed of single-beam scanning electron microscopes. We use multiple electron beams in a single column and detect secondary electrons in parallel to increase the imaging speed by close to two orders of magnitude and demonstrate imaging for a variety of samples ranging from biological brain tissue to semiconductor wafers. Lay Description The composition of our world and our bodies on the very small scale has always fascinated people, making them search for ways to make this visible to the human eye. Where light microscopes reach their resolution limit at a certain magnification, electron microscopes can go beyond. But their capability of visualizing extremely small features comes at the cost of a very small field of view. Some of the questions researchers seek to answer today deal with the ultrafine structure of brains, bones or computer chips. Capturing these objects with electron microscopes takes a lot of time – maybe even exceeding the time span of a human being – or new tools that do the job much faster. A new type of scanning electron microscope scans with 61 electron beams in parallel, acquiring 61 adjacent images of the sample at the same time a conventional scanning electron microscope captures one of these images. In principle, the multibeam scanning electron microscope’s field of view is 61 times larger and therefore coverage of the sample surface can be accomplished in less time. This enables researchers to think about large-scale projects, for example in the rather new field of connectomics. A very good introduction to imaging a brain at nanometre resolution can be found within course material from Harvard University on http://www.mcb80x.org/# as featured media entitled ‘connectomics’. PMID:25627873
Zheng, Zhi; Luo, Yuling; McMaster, Gary K
2006-07-01
Accurate and precise quantification of mRNA in whole blood is made difficult by gene expression changes during blood processing, and by variations and biases introduced by sample preparations. We sought to develop a quantitative whole-blood mRNA assay that eliminates blood purification, RNA isolation, reverse transcription, and target amplification while providing high-quality data in an easy assay format. We performed single- and multiplex gene expression analysis with multiple hybridization probes to capture mRNA directly from blood lysate and used branched DNA to amplify the signal. The 96-well plate singleplex assay uses chemiluminescence detection, and the multiplex assay combines Luminex-encoded beads with fluorescent detection. The single- and multiplex assays could quantitatively measure as few as 6000 and 24,000 mRNA target molecules (0.01 and 0.04 amoles), respectively, in up to 25 microL of whole blood. Both formats had CVs < 10% and dynamic ranges of 3-4 logs. Assay sensitivities allowed quantitative measurement of gene expression in the minority of cells in whole blood. The signals from whole-blood lysate correlated well with signals from purified RNA of the same sample, and absolute mRNA quantification results from the assay were similar to those obtained by quantitative reverse transcription-PCR. Both single- and multiplex assay formats were compatible with common anticoagulants and PAXgene-treated samples; however, PAXgene preparations induced expression of known antiapoptotic genes in whole blood. Both the singleplex and the multiplex branched DNA assays can quantitatively measure mRNA expression directly from small volumes of whole blood. The assay offers an alternative to current technologies that depend on RNA isolation and is amenable to high-throughput gene expression analysis of whole blood.
Real-Time, Single-Step Bioassay Using Nanoplasmonic Resonator With Ultra-High Sensitivity
NASA Technical Reports Server (NTRS)
Zhang, Xiang (Inventor); Chen, Fanqing Frank (Inventor); Su, Kai-Hang (Inventor); Wei, Qi-Huo (Inventor); Ellman, Jonathan A. (Inventor); Sun, Cheng (Inventor)
2014-01-01
A nanoplasmonic resonator (NPR) comprising a metallic nanodisk with alternating shielding layer(s), having a tagged biomolecule conjugated or tethered to the surface of the nanoplasmonic resonator for highly sensitive measurement of enzymatic activity. NPRs enhance Raman signals in a highly reproducible manner, enabling fast detection of protease and enzyme activity, such as Prostate Specific Antigen (paPSA), in real-time, at picomolar sensitivity levels. Experiments on extracellular fluid (ECF) from paPSA-positive cells demonstrate specific detection in a complex bio-fluid background in real-time single-step detection in very small sample volumes.
Real-time, single-step bioassay using nanoplasmonic resonator with ultra-high sensitivity
Zhang, Xiang; Ellman, Jonathan A; Chen, Fanqing Frank; Su, Kai-Hang; Wei, Qi-Huo; Sun, Cheng
2014-04-01
A nanoplasmonic resonator (NPR) comprising a metallic nanodisk with alternating shielding layer(s), having a tagged biomolecule conjugated or tethered to the surface of the nanoplasmonic resonator for highly sensitive measurement of enzymatic activity. NPRs enhance Raman signals in a highly reproducible manner, enabling fast detection of protease and enzyme activity, such as Prostate Specific Antigen (paPSA), in real-time, at picomolar sensitivity levels. Experiments on extracellular fluid (ECF) from paPSA-positive cells demonstrate specific detection in a complex bio-fluid background in real-time single-step detection in very small sample volumes.
Microfluidic cell isolation technology for drug testing of single tumor cells and their clusters.
Bithi, Swastika S; Vanapalli, Siva A
2017-02-02
Drug assays with patient-derived cells such as circulating tumor cells requires manipulating small sample volumes without loss of rare disease-causing cells. Here, we report an effective technology for isolating and analyzing individual tumor cells and their clusters from minute sample volumes using an optimized microfluidic device integrated with pipettes. The method involves using hand pipetting to create an array of cell-laden nanoliter-sized droplets immobilized in a microfluidic device without loss of tumor cells during the pipetting process. Using this technology, we demonstrate single-cell analysis of tumor cell response to the chemotherapy drug doxorubicin. We find that even though individual tumor cells display diverse uptake profiles of the drug, the onset of apoptosis is determined by accumulation of a critical intracellular concentration of doxorubicin. Experiments with clusters of tumor cells compartmentalized in microfluidic drops reveal that cells within a cluster have higher viability than their single-cell counterparts when exposed to doxorubicin. This result suggests that circulating tumor cell clusters might be able to better survive chemotherapy drug treatment. Our technology is a promising tool for understanding tumor cell-drug interactions in patient-derived samples including rare cells.
Efficient use of single molecule time traces to resolve kinetic rates, models and uncertainties
NASA Astrophysics Data System (ADS)
Schmid, Sonja; Hugel, Thorsten
2018-03-01
Single molecule time traces reveal the time evolution of unsynchronized kinetic systems. Especially single molecule Förster resonance energy transfer (smFRET) provides access to enzymatically important time scales, combined with molecular distance resolution and minimal interference with the sample. Yet the kinetic analysis of smFRET time traces is complicated by experimental shortcomings—such as photo-bleaching and noise. Here we recapitulate the fundamental limits of single molecule fluorescence that render the classic, dwell-time based kinetic analysis unsuitable. In contrast, our Single Molecule Analysis of Complex Kinetic Sequences (SMACKS) considers every data point and combines the information of many short traces in one global kinetic rate model. We demonstrate the potential of SMACKS by resolving the small kinetic effects caused by different ionic strengths in the chaperone protein Hsp90. These results show an unexpected interrelation between conformational dynamics and ATPase activity in Hsp90.
Nanopipettes: probes for local sample analysis.
Saha-Shah, Anumita; Weber, Anna E; Karty, Jonathan A; Ray, Steven J; Hieftje, Gary M; Baker, Lane A
2015-06-01
Nanopipettes (pipettes with diameters <1 μm) were explored as pressure-driven fluid manipulation tools for sampling nanoliter volumes of fluids. The fundamental behavior of fluids confined in the narrow channels of the nanopipette shank was studied to optimize sampling volume and probe geometry. This method was utilized to collect nanoliter volumes (<10 nL) of sample from single Allium cepa cells and live Drosophila melanogaster first instar larvae. Matrix assisted laser desorption/ionization-mass spectrometry (MALDI-MS) was utilized to characterize the collected sample. The use of nanopipettes for surface sampling of mouse brain tissue sections was also explored. Lipid analyses were performed on mouse brain tissues with spatial resolution of sampling as small as 50 μm. Nanopipettes were shown to be a versatile tool that will find further application in studies of sample heterogeneity and population analysis for a wide range of samples.
Delwart, Eric; Li, Linlin
2011-01-01
The genomes of numerous circoviruses and distantly related circular DNA viruses encoding a rolling circle replication initiator protein (Rep) have been characterized from the tissues of mammals, fish, insects, and plants (geminivirus and nanovirus), human and animal feces, in an algae cell, and in diverse environmental samples. We review the genome organization, phylogenetic relationships and initial prevalence studies of cycloviruses, a proposed new genus in the Circoviridae family. Viral fossil rep sequences were also identified integrated on the chromosomes of mammals, frogs, lancelets, crustaceans, mites, gastropods, roundworms, placozoans, hydrozoans, protozoans, land plants, fungi, algae, and phytoplasma bacterias and their plasmids, reflecting their past host range. An ancient origin for viruses with rep-encoding single stranded small circular genomes, predating the diversification of eukaryotes, is discussed. The cellular hosts and pathogenicity of many recently described rep-containing circular genomes remain to be determined. Future studies of the virome of single cell and multi-cellular eukaryotes are likely to further extend the known diversity and host-range of small rep-containing circular viral genomes. PMID:22155583
NASA Astrophysics Data System (ADS)
Benedict, Christopher J.; Rao, Ashok; Sanjeev, Ganesh; Okram, G. S.; Babu, P. D.
2016-01-01
In this communication, the effect of electron beam irradiation on the structural, electrical, thermo-electric power and magnetic properties of LaCoO3 cobaltites have been investigated. Rietveld refinement of XRD data reveals that all samples are single phased with rhombohedral structure. Increase in electrical resistivity data is observed with increase in dosage of electron beam irradiation. Analysis of the measured electrical resistivity data indicates that the small polaron hopping model is operative in the high temperature regime for all samples. The Seebeck coefficient (S) of the pristine and the irradiated samples exhibits a crossover from positive to negative values, and a colossal value of Seebeck coefficient (32.65 mV/K) is obtained for pristine sample, however, the value of S decreases with increase in dosage of irradiation. The analysis of Seebeck coefficient data confirms that the small polaron hopping model is operative in the high temperature region. The magnetization results give clear evidence of increase in effective magnetic moment due to increase in dosage of electron beam irradiation.
NASA Astrophysics Data System (ADS)
Benktander, John D.; Gizaw, Solomon T.; Gaunitz, Stefan; Novotny, Milos V.
2018-05-01
Glycoconjugates are directly or indirectly involved in many biological processes. Due to their complex structures, the structural elucidation of glycans and the exploration of their role in biological systems have been challenging. Glycan pools generated through release from glycoprotein or glycolipid mixtures can often be very complex. For the sake of procedural simplicity, many glycan profiling studies choose to concentrate on a single class of glycoconjugates. In this paper, we demonstrate it feasible to cover glycosphingolipids, N-glycans, and O-glycans isolated from the same sample. Small volumes of human blood serum and ascites fluid as well as small mouse brain tissue samples are sufficient to profile sequentially glycans from all three classes of glycoconjugates and even positively identify some mixture components through MALDI-MS and LC-ESI-MS. The results show that comprehensive glycan profiles can be obtained from the equivalent of 500-μg protein starting material or possibly less. These methodological improvements can help accelerating future glycomic comprehensive studies, especially for precious clinical samples.
NASA Astrophysics Data System (ADS)
Pollington, A. D.; Kinman, W.; Hanson, S. K.
2014-12-01
Recent advances in mass spectrometry have led to an improved ability to measure high precision isotope ratios at increasingly low analyte concentrations. Combining techniques for enhanced ionization with better counting of small ion beams, we routinely measure isotope ratios on 100's of pg uranium samples and ≤10 pg plutonium samples with relative standard deviations of 1‰ on major isotope ratios and 10‰ on minor ratios achievable. With slightly larger samples (≤1 ng total U), these precisions can be as low as 0.01‰ (10 ppm) and 1‰ respectively. These techniques can be applied to both nuclear forensics questions where only a small amount of sample is available, as well as geologic questions such as U-Pb or U-Th disequilibrium geochronology from either single small crystals, or microsampled domains from within a heterogeneous sample. The analytical setup is a Cetac Aridus II desolvating nebulizer interfaced with a ThermoScientific Neptune Plus equipped with a jet-type sample cone and x-type skimmer cone. The combination of the desolvating nebulizer with the enhanced cone setup leads to an increase in sensitivity on the order of 10x that of a standard glass spray chamber (~1000V/ppm U). The Neptune Plus is equipped with 9 Faraday cups and 5 electron multipliers (two behind RPQ energy filters for improved abundance sensitivtiy). This allows for the simultaneous collection of all isotopes of either U or Pu with a combination of Faraday cups (e.g., 235U and 238U) and electron multipliers (e.g., 234U and 236U) with other configurations also available (e.g., 235U and 238U can instead be measured on electron multipliers in small samples). As sample sizes get small, the contributions from environmental blanks, as well as interfering species, become increasing concerns. In this study, we will present data on efforts to minimize the contribution of environmental U using scaled down chemical procedures as well as the effect of polyatomic species on the precision and accuracy of actinide isotope measurements and what procedures can be applied to minimize interferences.
Ras activation by SOS: Allosteric regulation by altered fluctuation dynamics
Iversen, Lars; Tu, Hsiung-Lin; Lin, Wan-Chen; Christensen, Sune M.; Abel, Steven M.; Iwig, Jeff; Wu, Hung-Jen; Gureasko, Jodi; Rhodes, Christopher; Petit, Rebecca S.; Hansen, Scott D.; Thill, Peter; Yu, Cheng-Han; Stamou, Dimitrios; Chakraborty, Arup K.; Kuriyan, John; Groves, Jay T.
2014-01-01
Activation of the small guanosine triphosphatase H-Ras by the exchange factor Son of Sevenless (SOS) is an important hub for signal transduction. Multiple layers of regulation, through protein and membrane interactions, govern activity of SOS. We characterized the specific activity of individual SOS molecules catalyzing nucleotide exchange in H-Ras. Single-molecule kinetic traces revealed that SOS samples a broad distribution of turnover rates through stochastic fluctuations between distinct, long-lived (more than 100 seconds), functional states. The expected allosteric activation of SOS by Ras–guanosine triphosphate (GTP) was conspicuously absent in the mean rate. However, fluctuations into highly active states were modulated by Ras-GTP. This reveals a mechanism in which functional output may be determined by the dynamical spectrum of rates sampled by a small number of enzymes, rather than the ensemble average. PMID:24994643
Biomedical imaging with THz waves
NASA Astrophysics Data System (ADS)
Nguyen, Andrew
2010-03-01
We discuss biomedical imaging using radio waves operating in the terahertz (THz) range between 300 GHz to 3 THz. Particularly, we present the concept for two THz imaging systems. One system employs single antenna, transmitter and receiver operating over multi-THz-frequency simultaneously for sensing and imaging small areas of the human body or biological samples. Another system consists of multiple antennas, a transmitter, and multiple receivers operating over multi-THz-frequency capable of sensing and imaging simultaneously the whole body or large biological samples. Using THz waves for biomedical imaging promises unique and substantial medical benefits including extremely small medical devices, extraordinarily fine spatial resolution, and excellent contrast between images of diseased and healthy tissues. THz imaging is extremely attractive for detection of cancer in the early stages, sensing and imaging of tissues near the skin, and study of disease and its growth versus time.
Replicability and Robustness of GWAS for Behavioral Traits
Rietveld, Cornelius A.; Conley, Dalton; Eriksson, Nicholas; Esko, Tõnu; Medland, Sarah E.; Vinkhuyzen, Anna A.E.; Yang, Jian; Boardman, Jason D.; Chabris, Christopher F.; Dawes, Christopher T.; Domingue, Benjamin W.; Hinds, David A.; Johannesson, Magnus; Kiefer, Amy K.; Laibson, David; Magnusson, Patrik K. E.; Mountain, Joanna L.; Oskarsson, Sven; Rostapshova, Olga; Teumer, Alexander; Tung, Joyce Y.; Visscher, Peter M.; Benjamin, Daniel J.; Cesarini, David; Koellinger, Philipp D.
2015-01-01
A recent genome-wide association study (GWAS) of educational attainment identified three single-nucleotide polymorphisms (SNPs) that, despite their small effect sizes (each R2 ≈ 0.02%), reached genome-wide significance (p < 5×10−8) in a large discovery sample and replicated in an independent sample (p < 0.05). The study also reported associations between educational attainment and indices of SNPs called “polygenic scores.” We evaluate the robustness of these findings. Study 1 finds that all three SNPs replicate in another large (N = 34,428) independent sample. We also find that the scores remain predictive (R2 ≈ 2%) with stringent controls for stratification (Study 2) and in new within-family analyses (Study 3). Our results show that large and therefore well-powered GWASs can identify replicable genetic associations with behavioral traits. The small effect sizes of individual SNPs are likely to be a major contributing explanation for the striking contrast between our results and the disappointing replication record of most candidate gene studies. PMID:25287667
Detecting Noisy Events Using Waveform Cross-Correlation at Superarrays of Seismic Stations
NASA Astrophysics Data System (ADS)
von Seggern, D. H.; Tibuleac, I. M.
2007-12-01
Cross-correlation using master events, followed by stacking of the correlation series, has been shown to dramatically improve detection thresholds of small-to-medium seismic arrays. With the goal of lowering the detection threshold, determining relative magnitudes or moments, and characterizing sources by empirical Green's functions, we extend the cross-correlation methodology to include "superarrays" of seismic stations. The superarray concept naturally brings further benefits over conventional arrays and single-stations due to the fact that many distances and azimuths can be sampled. This extension is straightforward given the ease with which regional or global data from various stations or arrays can be currently accessed and combined into a single database. We demonstrate the capability of superarrays to detect and analyze events which lie below the detection threshold. This is aided by applying an F-statistic detector to the superarray cross-correlation stack and its components. Our first example illustrates the use of a superarray consisting of the Southern Great Basin Digital Seismic Network, a small-aperture array (NVAR) in Mina, Nevada and the Earthscope Transportable Array to detect events in California-Nevada areas. In our second example, we use a combination of small-to-medium arrays and single stations to study the rupture of the great Sumatra earthquake of 26 December 2004 and to detect its early aftershocks. The location and times of "detected" events are confirmed using a frequency- wavenumber method at the small-to-medium arrays. We propose that ad hoc superarrays can be used in many studies where conventional approaches previously used only single arrays or groups of single stations. The availability of near-real-time data from many networks and of archived data from, for instance, IRIS makes possible the easy assembly of superarrays. Furthermore, the continued improvement of seismic data availability and the continued growth in the number of world-wide seismic sensors will increasingly make superarrays an attractive choice for many studies.
Microwave heating and joining of ceramic cylinders: A mathematical model
NASA Technical Reports Server (NTRS)
Booty, Michael R.; Kriegsmann, Gregory A.
1994-01-01
A thin cylindrical ceramic sample is placed in a single mode microwave applicator in such a way that the electric field strength is allowed to vary along its axis. The sample can either be a single rod or two rods butted together. We present a simple mathematical model which describes the microwave heating process. It is built on the assumption that the Biot number of the material is small, and that the electric field is known and uniform throughout the cylinder's cross-section. The model takes the form of a nonlinear parabolic equation of reaction-diffusion type, with a spatially varying reaction term that corresponds to the spatial variation of the electromagnetic field strength in the waveguide. The equation is analyzed and a solution is found which develops a hot spot near the center of the cylindrical sample and which then propagates outwards until it stabilizes. The propagation and stabilization phenomenon concentrates the microwave energy in a localized region about the center where elevated temperatures may be desirable.
Zhu, Ying; Piehowski, Paul D; Zhao, Rui; Chen, Jing; Shen, Yufeng; Moore, Ronald J; Shukla, Anil K; Petyuk, Vladislav A; Campbell-Thompson, Martha; Mathews, Clayton E; Smith, Richard D; Qian, Wei-Jun; Kelly, Ryan T
2018-02-28
Nanoscale or single-cell technologies are critical for biomedical applications. However, current mass spectrometry (MS)-based proteomic approaches require samples comprising a minimum of thousands of cells to provide in-depth profiling. Here, we report the development of a nanoPOTS (nanodroplet processing in one pot for trace samples) platform for small cell population proteomics analysis. NanoPOTS enhances the efficiency and recovery of sample processing by downscaling processing volumes to <200 nL to minimize surface losses. When combined with ultrasensitive liquid chromatography-MS, nanoPOTS allows identification of ~1500 to ~3000 proteins from ~10 to ~140 cells, respectively. By incorporating the Match Between Runs algorithm of MaxQuant, >3000 proteins are consistently identified from as few as 10 cells. Furthermore, we demonstrate quantification of ~2400 proteins from single human pancreatic islet thin sections from type 1 diabetic and control donors, illustrating the application of nanoPOTS for spatially resolved proteome measurements from clinical tissues.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhu, Ying; Piehowski, Paul D.; Zhao, Rui
Nanoscale or single-cell technologies are critical for biomedical applications. However, current mass spectrometry (MS)-based proteomic approaches require samples comprising a minimum of thousands of cells to provide in-depth profiling. Here in this paper, we report the development of a nanoPOTS (nanodroplet processing in one pot for trace samples) platform for small cell population proteomics analysis. NanoPOTS enhances the efficiency and recovery of sample processing by downscaling processing volumes to <200 nL to minimize surface losses. When combined with ultrasensitive liquid chromatography-MS, nanoPOTS allows identification of ~1500 to ~3000 proteins from ~10 to ~140 cells, respectively. By incorporating the Match Betweenmore » Runs algorithm of MaxQuant, >3000 proteins are consistently identified from as few as 10 cells. Furthermore, we demonstrate quantification of ~2400 proteins from single human pancreatic islet thin sections from type 1 diabetic and control donors, illustrating the application of nanoPOTS for spatially resolved proteome measurements from clinical tissues.« less
Zhu, Ying; Piehowski, Paul D.; Zhao, Rui; ...
2018-02-28
Nanoscale or single-cell technologies are critical for biomedical applications. However, current mass spectrometry (MS)-based proteomic approaches require samples comprising a minimum of thousands of cells to provide in-depth profiling. Here in this paper, we report the development of a nanoPOTS (nanodroplet processing in one pot for trace samples) platform for small cell population proteomics analysis. NanoPOTS enhances the efficiency and recovery of sample processing by downscaling processing volumes to <200 nL to minimize surface losses. When combined with ultrasensitive liquid chromatography-MS, nanoPOTS allows identification of ~1500 to ~3000 proteins from ~10 to ~140 cells, respectively. By incorporating the Match Betweenmore » Runs algorithm of MaxQuant, >3000 proteins are consistently identified from as few as 10 cells. Furthermore, we demonstrate quantification of ~2400 proteins from single human pancreatic islet thin sections from type 1 diabetic and control donors, illustrating the application of nanoPOTS for spatially resolved proteome measurements from clinical tissues.« less
Multiplexed mass cytometry profiling of cellular states perturbed by small-molecule regulators
Bodenmiller, Bernd; Zunder, Eli R.; Finck, Rachel; Chen, Tiffany J.; Savig, Erica S.; Bruggner, Robert V.; Simonds, Erin F.; Bendall, Sean C.; Sachs, Karen; Krutzik, Peter O.; Nolan, Garry P.
2013-01-01
The ability to comprehensively explore the impact of bio-active molecules on human samples at the single-cell level can provide great insight for biomedical research. Mass cytometry enables quantitative single-cell analysis with deep dimensionality, but currently lacks high-throughput capability. Here we report a method termed mass-tag cellular barcoding (MCB) that increases mass cytometry throughput by sample multiplexing. 96-well format MCB was used to characterize human peripheral blood mononuclear cell (PBMC) signaling dynamics, cell-to-cell communication, the signaling variability between 8 donors, and to define the impact of 27 inhibitors on this system. For each compound, 14 phosphorylation sites were measured in 14 PBMC types, resulting in 18,816 quantified phosphorylation levels from each multiplexed sample. This high-dimensional systems-level inquiry allowed analysis across cell-type and signaling space, reclassified inhibitors, and revealed off-target effects. MCB enables high-content, high-throughput screening, with potential applications for drug discovery, pre-clinical testing, and mechanistic investigation of human disease. PMID:22902532
Hollow fiber-optic Raman probes for small experimental animals
NASA Astrophysics Data System (ADS)
Katagiri, Takashi; Hattori, Yusuke; Suzuki, Toshiaki; Matsuura, Yuji; Sato, Hidetoshi
2007-02-01
Two types of hollow fiber-optic probes are developed to measure the in vivo Raman spectra of small animals. One is the minimized probe which is end-sealed with the micro-ball lens. The measured spectra reflect the information of the sample's sub-surface. This probe is used for the measurement of the esophagus and the stomach via an endoscope. The other probe is a confocal Raman probe which consists of a single fiber and a lens system. It is integrated into the handheld microscope. A simple and small multimodal probe is realized because the hollow optical fiber requires no optical filters. The performance of each probe is examined and the effectiveness of these probes for in vivo Raman spectroscopy is shown by animal tests.
Experimental Acquisitions with ^125I on a Small Animal SPECT Device*
NASA Astrophysics Data System (ADS)
Knott, Kevin; Welsh, Robert E.; Bradley, Eric L.; Saha, Margaret S.; Kross, Brian; Majewski, Stan; Popov, Vladimir; Smith, Mark F.; Weisenberger, Andrew G.; Wojcik, Randolph
2001-04-01
We have performed single photon emission computed tomography (SPECT) studies on a small animal scanning system for which the detector employed position sensitive phototubes (125 mm dia. Hamamatsu R3292 and 18 x 18 mm Hamamatsu M-64) coupled to pixelated scintillators CsI(Tl) and CsI(Na) Phantom acquisitions were used to investigate the effects of angular sampling and scan time on reconstructed image quality and noise. Results from these studies will be described and extended to in vivo studies with small animals. *Supported in part by the Thomas F. and Kate Miller Jeffress Trust, the Department of Energy, The American Diabetes Association, The National Science Foundation, the Howard Hughes Foundation and the Virginia Commonwealth Health Research Board.
Cuozzo, Frank P; Rasoazanabary, Emilienne; Godfrey, Laurie R; Sauther, Michelle L; Youssouf, Ibrahim Antho; LaFleur, Marni M
2013-01-01
A thorough knowledge of biological variation in extant primates is imperative for interpreting variation, and for delineating species in primate biology and paleobiology. This is especially the case given the recent, rapid taxonomic expansion in many primate groups, notably among small-bodied nocturnal forms. Here we present data on dental, cranial, and pelage variation in a single-locality museum sample of mouse lemurs from Amboasary, Madagascar. To interpret these data, we include comparative information from other museum samples, and from a newly collected mouse lemur skeletal sample from the Beza Mahafaly Special Reserve (BMSR), Madagascar. We scored forty dental traits (n = 126) and three pelage variants (n = 19), and collected 21 cranial/dental measures. Most dental traits exhibit variable frequencies, with some only rarely present. Individual dental variants include misshapen and supernumerary teeth. All Amboasary pelage specimens display a "reversed V" on the cap, and a distinct dorsal median stripe on the back. All but two displayed the dominant gray-brown pelage coloration typical of Microcebus griseorufus. Cranial and dental metric variability are each quite low, and craniometric variation does not illustrate heteroscedasticity. To assess whether this sample represents a single species, we compared dental and pelage variation to a documented, single-species M. griseorufus sample from BMSR. As at Amboasary, BMSR mouse lemurs display limited odontometric variation and wide variation in non-metric dental traits. In contrast, BMSR mouse lemurs display diverse pelage, despite reported genetic homogeneity. Ranges of dental and pelage variation at BMSR and Amboasary overlap. Thus, we conclude that the Amboasary mouse lemurs represent a single species - most likely (in the absence of genetic data to the contrary) M. griseorufus, and we reject their previous allocation to Microcebus murinus. Patterns of variation in the Amboasary sample provide a comparative template for recognizing the degree of variation manifested in a single primate population, and by implication, they provide minimum values for this species' intraspecific variation. Finally, discordance between different biological systems in our mouse lemur samples illustrates the need to examine multiple systems when conducting taxonomic analyses among living or fossil primates. Copyright © 2012 Elsevier Ltd. All rights reserved.
Ferrara, Toni L; Boughton, Philip; Slavich, Eve; Wroe, Stephen
2013-01-01
Nanomechanical testing methods that are suitable for a range of hydrated tissues are crucial for understanding biological systems. Nanoindentation of tissues can provide valuable insights into biology, tissue engineering and biomimetic design. However, testing hydrated biological samples still remains a significant challenge. Shark jaw cartilage is an ideal substrate for developing a method to test hydrated tissues because it is a unique heterogeneous composite of both mineralized (hard) and non-mineralized (soft) layers and possesses a jaw geometry that is challenging to test mechanically. The aim of this study is to develop a novel method for obtaining multidirectional nanomechanical properties for both layers of jaw cartilage from a single sample, taken from the great white shark (Carcharodon carcharias). A method for obtaining multidirectional data from a single sample is necessary for examining tissue mechanics in this shark because it is a protected species and hence samples may be difficult to obtain. Results show that this method maintains hydration of samples that would otherwise rapidly dehydrate. Our study is the first analysis of nanomechanical properties of great white shark jaw cartilage. Variation in nanomechanical properties were detected in different orthogonal directions for both layers of jaw cartilage in this species. The data further suggest that the mineralized layer of shark jaw cartilage is less stiff than previously posited. Our method allows multidirectional nanomechanical properties to be obtained from a single, small, hydrated heterogeneous sample. Our technique is therefore suitable for use when specimens are rare, valuable or limited in quantity, such as samples obtained from endangered species or pathological tissues. We also outline a method for tip-to-optic calibration that facilitates nanoindentation of soft biological tissues. Our technique may help address the critical need for a nanomechanical testing method that is applicable to a variety of hydrated biological materials whether soft or hard.
Ling, Shaoping; Hu, Zheng; Yang, Zuyu; Yang, Fang; Li, Yawei; Lin, Pei; Chen, Ke; Dong, Lili; Cao, Lihua; Tao, Yong; Hao, Lingtong; Chen, Qingjian; Gong, Qiang; Wu, Dafei; Li, Wenjie; Zhao, Wenming; Tian, Xiuyun; Hao, Chunyi; Hungate, Eric A; Catenacci, Daniel V T; Hudson, Richard R; Li, Wen-Hsiung; Lu, Xuemei; Wu, Chung-I
2015-11-24
The prevailing view that the evolution of cells in a tumor is driven by Darwinian selection has never been rigorously tested. Because selection greatly affects the level of intratumor genetic diversity, it is important to assess whether intratumor evolution follows the Darwinian or the non-Darwinian mode of evolution. To provide the statistical power, many regions in a single tumor need to be sampled and analyzed much more extensively than has been attempted in previous intratumor studies. Here, from a hepatocellular carcinoma (HCC) tumor, we evaluated multiregional samples from the tumor, using either whole-exome sequencing (WES) (n = 23 samples) or genotyping (n = 286) under both the infinite-site and infinite-allele models of population genetics. In addition to the many single-nucleotide variations (SNVs) present in all samples, there were 35 "polymorphic" SNVs among samples. High genetic diversity was evident as the 23 WES samples defined 20 unique cell clones. With all 286 samples genotyped, clonal diversity agreed well with the non-Darwinian model with no evidence of positive Darwinian selection. Under the non-Darwinian model, MALL (the number of coding region mutations in the entire tumor) was estimated to be greater than 100 million in this tumor. DNA sequences reveal local diversities in small patches of cells and validate the estimation. In contrast, the genetic diversity under a Darwinian model would generally be orders of magnitude smaller. Because the level of genetic diversity will have implications on therapeutic resistance, non-Darwinian evolution should be heeded in cancer treatments even for microscopic tumors.
NASA Astrophysics Data System (ADS)
Shcherbakov, V. P.; Shcherbakova, V. V.
2001-07-01
We report an experimental and theoretical study of non-linear Arai-Nagata diagrams for samples containing pseudo-single-domain (PSD) and multidomain (MD) magnetite. Our aim is to reveal the physical reasons for the deviation of these plots from ideal straight lines. Contrary to expectations, the concavity of the Arai-Nagata diagrams is not related to the two most noticeable violations of the Thellier laws documented for non-single-domain particles: the tail of partial thermoremanence and the dependence of the magnitude of pTRM on the thermal history of the sample. Indeed, the contributions from these two factors mutually cancel each other. Phenomenologically, the non-linear Arai-Nagata plots occur because samples during low-temperature stages of the Thellier procedure lose too much remanence and recover too little of it. The excessive loss of the previously imparted total TRM is due at least partly to some partial demagnetization of high-temperature TRM components and to progressive stabilization of domain structure during the repetitive heatings to moderate temperatures that form the basis of the Thellier procedure. For natural MD samples a linear fit to the low-temperature data points on the Arai-Nagata plots leads to a palaeointensity overestimated by as much as 60 per cent. The samples containing hydrothermally grown or crushed and sieved MD magnetite provide low-temperature apparent palaeointensities two to three times larger than the correct value. For small PSD samples the overestimate is less than 10-20 per cent and, in general, PSD samples can be used for the palaeointensity determinations.
Ling, Shaoping; Hu, Zheng; Yang, Zuyu; Yang, Fang; Li, Yawei; Lin, Pei; Chen, Ke; Dong, Lili; Cao, Lihua; Tao, Yong; Hao, Lingtong; Chen, Qingjian; Gong, Qiang; Wu, Dafei; Li, Wenjie; Zhao, Wenming; Tian, Xiuyun; Hao, Chunyi; Hungate, Eric A.; Catenacci, Daniel V. T.; Hudson, Richard R.; Li, Wen-Hsiung; Lu, Xuemei; Wu, Chung-I
2015-01-01
The prevailing view that the evolution of cells in a tumor is driven by Darwinian selection has never been rigorously tested. Because selection greatly affects the level of intratumor genetic diversity, it is important to assess whether intratumor evolution follows the Darwinian or the non-Darwinian mode of evolution. To provide the statistical power, many regions in a single tumor need to be sampled and analyzed much more extensively than has been attempted in previous intratumor studies. Here, from a hepatocellular carcinoma (HCC) tumor, we evaluated multiregional samples from the tumor, using either whole-exome sequencing (WES) (n = 23 samples) or genotyping (n = 286) under both the infinite-site and infinite-allele models of population genetics. In addition to the many single-nucleotide variations (SNVs) present in all samples, there were 35 “polymorphic” SNVs among samples. High genetic diversity was evident as the 23 WES samples defined 20 unique cell clones. With all 286 samples genotyped, clonal diversity agreed well with the non-Darwinian model with no evidence of positive Darwinian selection. Under the non-Darwinian model, MALL (the number of coding region mutations in the entire tumor) was estimated to be greater than 100 million in this tumor. DNA sequences reveal local diversities in small patches of cells and validate the estimation. In contrast, the genetic diversity under a Darwinian model would generally be orders of magnitude smaller. Because the level of genetic diversity will have implications on therapeutic resistance, non-Darwinian evolution should be heeded in cancer treatments even for microscopic tumors. PMID:26561581
Cesar, D; Maxson, J; Musumeci, P; Sun, Y; Harrison, J; Frigola, P; O'Shea, F H; To, H; Alesini, D; Li, R K
2016-07-08
We present the results of an experiment where a short focal length (∼1.3 cm), permanent magnet electron lens is used to image micron-size features (of a metal sample) with a single shot from an ultrahigh brightness picosecond-long 4 MeV electron beam emitted by a radio-frequency photoinjector. Magnification ratios in excess of 30× were obtained using a triplet of compact, small gap (3.5 mm), Halbach-style permanent magnet quadrupoles with nearly 600 T/m field gradients. These results pave the way towards single-shot time-resolved electron microscopy and open new opportunities in the applications of high brightness electron beams.
Dependence of Ag/Ga composition ratio in AgGaSe2 thin film
NASA Astrophysics Data System (ADS)
Matsuo, H.; Yoshino, K.; Ikari, T.
2006-09-01
AgGaSe2 thin film was deposited on glass substrates by vacuum evaporation method. The starting material was mixed Ag2Se and Ga2Se3 powders. Ag/Ga ratios of the samples were 1.5, 1.2, 1.0, 0.8, 0.7 and 0.4. The samples were annealed from 100 to 600 °C for 10 min. After these processes, single phase AgGaSe2 thin films could be obtained except Ag/Ga ratio of 0.4 at annealing temperature of 600 °C. Ag-rich samples had large grain. On the other hand, Ga-rich samples had small grain. Furthermore, Ga-rich and Ag-rich samples indicated p- and n-types because of Ag- and/or Ga-vacancy and Se-vacancy, respectively.
Correlation between structural and transport properties of electron beam irradiated PrMnO3 compounds
NASA Astrophysics Data System (ADS)
Christopher, Benedict; Rao, Ashok; Nagaraja, B. S.; Shyam Prasad, K.; Okram, G. S.; Sanjeev, Ganesh; Petwal, Vikash Chandra; Verma, Vijay Pal; Dwivedi, Jishnu; Poornesh, P.
2018-02-01
The structural, electrical, magnetic, and thermal properties of electron beam (EB) irradiated PrMnO3 manganites were investigated in the present communication. X-ray diffraction data reveals that all samples are single phased with orthorhombic distorted structure (Pbnm). Furthermore, the diffracted data are analyzed in detail using Rietveld refinement technique. It is observed that the EB dosage feebly disturbs the MnO6 octahedra. The electrical resistivity of all the samples exhibits semiconducting behavior. Small polaron hopping model is conveniently employed to investigate the semiconducting nature of the pristine as well as EB irradiated samples. The Seebeck coefficient (S) of the pristine as well as the irradiated samples exhibit large positive values at lower temperatures, signifying holes as the dominant charge carriers. The analysis of Seebeck coefficient data confirms that the small polaron hopping mechanism assists the thermoelectric transport property in the high temperature region. The magnetic measurements confirm the existence of paramagnetic (PM) to ferromagnetic (FM) behavior for the pristine and irradiated samples. In the lower temperature regime, coexistence of FM clusters and AFM matrix is dominating. Thus, the complex magnetic behavior of the compound has been explained in terms of rearrangement of antiferromagnetically coupled ionic moments.
Pillay, Pavitra; Taylor, Myra; Zulu, Siphosenkosi G.; Gundersen, Svein G.; Verweij, Jaco J.; Hoekstra, Pytsje; Brienen, Eric A. T.; Kleppa, Elisabeth; Kjetland, Eyrun F.; van Lieshout, Lisette
2014-01-01
Schistosoma haematobium eggs and Schistosoma DNA levels were measured in urine samples from 708 girls recruited from 18 randomly sampled primary schools in South Africa. Microscopic analysis of two 10-mL urine subsamples collected on three consecutive days confirmed high day-to-day variation; 103 (14.5%) girls had positive results at all six examinations, and at least one positive sample was seen in 225 (31.8%) girls. Schistosoma-specific DNA, which was measured in a 200-μL urine subsample by using real-time polymerase chain reaction, was detected in 180 (25.4%) cases, and levels of DNA corresponded significantly with average urine egg excretion. In concordance with microscopic results, polymerase chain reaction results were significantly associated with history of gynecologic symptoms and confirmed highly focal distribution of urogenital schistosomiasis. Parasite-specific DNA detection has a sensitivity comparable to single urine microscopy and could be used as a standardized high-throughput procedure to assess distribution of urogenital schistosomiasis in relatively large study populations by using small sample volumes. PMID:24470560
Virtual substitution scan via single-step free energy perturbation.
Chiang, Ying-Chih; Wang, Yi
2016-02-05
With the rapid expansion of our computing power, molecular dynamics (MD) simulations ranging from hundreds of nanoseconds to microseconds or even milliseconds have become increasingly common. The majority of these long trajectories are obtained from plain (vanilla) MD simulations, where no enhanced sampling or free energy calculation method is employed. To promote the 'recycling' of these trajectories, we developed the Virtual Substitution Scan (VSS) toolkit as a plugin of the open-source visualization and analysis software VMD. Based on the single-step free energy perturbation (sFEP) method, VSS enables the user to post-process a vanilla MD trajectory for a fast free energy scan of substituting aryl hydrogens by small functional groups. Dihedrals of the functional groups are sampled explicitly in VSS, which improves the performance of the calculation and is found particularly important for certain groups. As a proof-of-concept demonstration, we employ VSS to compute the solvation free energy change upon substituting the hydrogen of a benzene molecule by 12 small functional groups frequently considered in lead optimization. Additionally, VSS is used to compute the relative binding free energy of four selected ligands of the T4 lysozyme. Overall, the computational cost of VSS is only a fraction of the corresponding multi-step FEP (mFEP) calculation, while its results agree reasonably well with those of mFEP, indicating that VSS offers a promising tool for rapid free energy scan of small functional group substitutions. This article is protected by copyright. All rights reserved. © 2016 Wiley Periodicals, Inc.
A genetic investigation of Korean mummies from the Joseon Dynasty.
Kim, Na Young; Lee, Hwan Young; Park, Myung Jin; Yang, Woo Ick; Shin, Kyoung-Jin
2011-01-01
Two Korean mummies (Danwoong-mirra and Yoon-mirra) found in medieval tombs in the central region of the Korean peninsula were genetically investigated by analysis of mitochondrial DNA (mtDNA), Y-chromosomal short tandem repeat (Y-STR) and the ABO gene. Danwoong-mirra is a male child mummy and Yoon-mirra is a pregnant female mummy, dating back about 550 and 450 years, respectively. DNA was extracted from soft tissues or bones. mtDNA, Y-STR and the ABO gene were amplified using a small size amplicon strategy and were analyzed according to the criteria of ancient DNA analysis to ensure that authentic DNA typing results were obtained from these ancient samples. Analysis of mtDNA hypervariable region sequence and coding region single nucleotide polymorphism (SNP) information revealed that Danwoong-mirra and Yoon-mirra belong to the East Asian mtDNA haplogroups D4 and M7c, respectively. The Y-STRs were analyzed in the male child mummy (Danwoong-mirra) using the AmpFlSTR® Yfiler PCR Amplification Kit and an in-house Y-miniplex plus system, and could be characterized in 4 loci with small amplicon size. The analysis of ABO gene SNPs using multiplex single base extension methods revealed that the ABO blood types of Danwoong-mirra and Yoon-mirra are AO01 and AB, respectively. The small size amplicon strategy and the authentication process in the present study will be effectively applicable to future genetic analyses of various forensic and ancient samples.
Fast Raman single bacteria identification: toward a routine in-vitro diagnostic
NASA Astrophysics Data System (ADS)
Douet, Alice; Josso, Quentin; Marchant, Adrien; Dutertre, Bertrand; Filiputti, Delphine; Novelli-Rousseau, Armelle; Espagnon, Isabelle; Kloster-Landsberg, Meike; Mallard, Frédéric; Perraut, Francois
2016-04-01
Timely microbiological results are essential to allow clinicians to optimize the prescribed treatment, ideally at the initial stage of the therapeutic process. Several approaches have been proposed to solve this issue and to provide the microbiological result in a few hours directly from the sample such as molecular biology. However fast and sensitive those methods are not based on single phenotypic information which presents several drawbacks and limitations. Optical methods have the advantage to allow single-cell sensitivity and to probe the phenotype of measured cells. Here we present a process and a prototype that allow automated single-bacteria phenotypic analysis. This prototype is based on the use of Digital In-line Holography techniques combined with a specially designed Raman spectrometer using a dedicated device to capture bacteria. The localization of single-cell is finely determined by using holograms and a proper propagation kernel. Holographic images are also used to analyze bacteria in the sample to sort potential pathogens from flora dwelling species or other biological particles. This accurate localization enables the use of a small confocal volume adapted to the measurement of single-cell. Along with the confocal volume adaptation, we also have modified every components of the spectrometer to optimize single-bacteria Raman measurements. This optimization allowed us to acquire informative single-cell spectra using an integration time of 0.5s only. Identification results obtained with this prototype are presented based on a 65144 Raman spectra database acquired automatically on 48 bacteria strains belonging to 8 species.
A microplate assay for DNA damage determination (fast micromethod).
Batel, R; Jaksić, Z; Bihari, N; Hamer, B; Fafandel, M; Chauvin, C; Schröder, H C; Müller, W E; Zahn, R K
1999-06-01
A rapid and convenient procedure for DNA damage determination in cell suspensions and solid tissues on single microplates was developed. The procedure is based on the ability of commercially available fluorochromes to interact preferentially with dsDNA in the presence of ssDNA, RNA, and proteins at high pH (>12.0), thus allowing direct measurements of DNA denaturation without sample handling or stepwise DNA separations. The method includes a simple and rapid 40-min sample lysis in the presence of EDTA, SDS, and high urea concentration at pH 10, followed by time-dependent DNA denaturation at pH 12.4 after NaOH addition. The time course and the extent of DNA denaturation is followed in a microplate fluorescence reader at room temperature for less than 1 h. The method requires only 30 ng DNA per single well and could conveniently be used whenever fast analysis of DNA integrity in small samples has to be done, e.g., in patients' lymphocytes after irradiation or chemotherapy (about 3000 cells per sample), in solid tissues or biopsies after homogenization (about 25 microg tissue per well), or in environmental samples for genotoxicity assessment. Copyright 1999 Academic Press.
Song, Rui; Kosorok, Michael R.; Cai, Jianwen
2009-01-01
Summary Recurrent events data are frequently encountered in clinical trials. This article develops robust covariate-adjusted log-rank statistics applied to recurrent events data with arbitrary numbers of events under independent censoring and the corresponding sample size formula. The proposed log-rank tests are robust with respect to different data-generating processes and are adjusted for predictive covariates. It reduces to the Kong and Slud (1997, Biometrika 84, 847–862) setting in the case of a single event. The sample size formula is derived based on the asymptotic normality of the covariate-adjusted log-rank statistics under certain local alternatives and a working model for baseline covariates in the recurrent event data context. When the effect size is small and the baseline covariates do not contain significant information about event times, it reduces to the same form as that of Schoenfeld (1983, Biometrics 39, 499–503) for cases of a single event or independent event times within a subject. We carry out simulations to study the control of type I error and the comparison of powers between several methods in finite samples. The proposed sample size formula is illustrated using data from an rhDNase study. PMID:18162107
Bedside arterial blood gas monitoring system using fluorescent optical sensors
NASA Astrophysics Data System (ADS)
Bartnik, Daniel J.; Rymut, Russell A.
1995-05-01
We describe a bedside arterial blood gas (ABG) monitoring system which uses fluorescent optical sensors in the measurement of blood pH, PCO2 and PO2. The Point-of-Care Arterial Blood Gas Monitoring System consists of the SensiCathTM optical sensor unit manufactured by Optical Sensors Incorporated and the TramTM Critical Care Monitoring System with ABG Module manufactured by Marquette Electronics Incorporated. Current blood gas measurement techniques require a blood sample to be removed from the patient and transported to an electrochemical analyzer for analysis. The ABG system does not require removal of blood from the patient or transport of the sample. The sensor is added to the patient's existing arterial line. ABG measurements are made by drawing a small blood sample from the arterial line in sufficient quantity to ensure an undiluted sample at the sensor. Measurements of pH, PCO2 and PO2 are made within 60 seconds. The blood is then returned to the patient, the line flushed and results appear on the bedside monitor. The ABG system offers several advantages over traditional electrochemical analyzers. Since the arterial line remains closed during the blood sampling procedure the patient's risk of infection is reduced and the caregiver's exposure to blood is eliminated. The single-use, disposable sensor can be measure 100 blood samples over 72 hours after a single two-point calibration. Quality Assurance checks are also available and provide the caregiver the ability to assess system performance even after the sensor is patient attached. The ABG module integrates with an existing bedside monitoring system. This allows ABG results to appear on the same display as ECG, respiration, blood pressure, cardiac output, SpO2, and other clinical information. The small module takes up little space in the crowded intensive care unit. Performance studies compare the ABG system with an electrochemical blood gas analyzer. Study results demonstrated accurate and precise blood gas measurement of 100 samples and 72 hour performance without need for re-calibration.
High-throughput biological small-angle X-ray scattering with a robotically loaded capillary cell
Nielsen, S. S.; Møller, M.; Gillilan, R. E.
2012-01-01
With the rise in popularity of biological small-angle X-ray scattering (BioSAXS) measurements, synchrotron beamlines are confronted with an ever-increasing number of samples from a wide range of solution conditions. To meet these demands, an increasing number of beamlines worldwide have begun to provide automated liquid-handling systems for sample loading. This article presents an automated sample-loading system for BioSAXS beamlines, which combines single-channel disposable-tip pipetting with a vacuum-enclosed temperature-controlled capillary flow cell. The design incorporates an easily changeable capillary to reduce the incidence of X-ray window fouling and cross contamination. Both the robot-control and the data-processing systems are written in Python. The data-processing code, RAW, has been enhanced with several new features to form a user-friendly BioSAXS pipeline for the robot. The flow cell also supports efficient manual loading and sample recovery. An effective rinse protocol for the sample cell is developed and tested. Fluid dynamics within the sample capillary reveals a vortex ring pattern of circulation that redistributes radiation-damaged material. Radiation damage is most severe in the boundary layer near the capillary surface. At typical flow speeds, capillaries below 2 mm in diameter are beginning to enter the Stokes (creeping flow) regime in which mixing due to oscillation is limited. Analysis within this regime shows that single-pass exposure and multiple-pass exposure of a sample plug are functionally the same with regard to exposed volume when plug motion reversal is slow. The robot was tested on three different beamlines at the Cornell High-Energy Synchrotron Source, with a variety of detectors and beam characteristics, and it has been used successfully in several published studies as well as in two introductory short courses on basic BioSAXS methods. PMID:22509071
Beyond the Quantum Hall Effect: New Phases of 2D Electrons at High Magnetic Field
NASA Astrophysics Data System (ADS)
Eisenstein, James
2007-03-01
In this talk I will discuss recent experiments on high mobility single and double layer 2D electron systems in which collective phases lying outside the usual quantum Hall effect paradigm have been detected and studied. For example, in single layer 2D systems near half-filling of highly excited Landau levels new states characterized by a massive anisotropy in the electrical resistivity of the sample are observed at very low temperature. The anisotropy has been widely interpreted as the signature of a new class of correlated electron phases which incorporate a stripe-like charge density modulation. Orientational ordering of small striped domains at low temperatures accounts for the resistive anisotropy and is reminiscent of the isotropic-to-nematic phase transition in classical liquid crystals. Double layer 2D electron systems possess collective phases not present in single layer systems. In particular, when the total number of electrons in the bilayer equals the degeneracy of a single Landau level, an unusual phase appears at small layer separation. This phase possesses a novel broken symmetry, spontaneous interlayer phase coherence, which has a number of dramatic experimental signatures. The interlayer tunneling conductance develops a strong and very sharp resonance around zero bias resembling the dc Josephson effect. At the same time, both the longitudinal and Hall resistances of the sample vanish at low temperatures when currents are driven in opposite directions through the two layers. These, and other observations are broadly consistent with theories in which the broken symmetry phase can equivalently be described as a pseudospin ferromagnet or an (imperfect) excitonic superfluid. This work reflects a collaboration with M.P. Lilly, K.B. Cooper, I.B. Spielman, M. Kellogg, L.A. Tracy, L.N. Pfeiffer, and K.W. West.
Lu, Chungui; Koroleva, Olga A; Farrar, John F; Gallagher, Joe; Pollock, Chris J; Tomos, A Deri
2002-11-01
We describe a highly efficient two-step single-cell reverse transcriptase-polymerase chain reaction technique for analyzing gene expression at the single-cell level. Good reproducibility and a linear dose response indicated that the technique has high specificity and sensitivity for detection and quantification of rare RNA. Actin could be used as an internal standard. The expression of message for Rubisco small subunit (RbcS), chlorophyll a/b-binding protein (Cab), sucrose (Suc):fructan-6-fructosyl transferase (6-SFT), and Actin were measured in individual photosynthetic cells of the barley (Hordeum vulgare) leaf. Only Actin was found in the non-photosynthetic epidermal cells. Cab, RbcS, and 6-SFT genes were expressed at a low level in mesophyll and parenchymatous bundle sheath (BS) cells when sampled from plants held in dark for 40 h. Expression increased considerably after illumination. The amount of 6-SFT, Cab, and RbcS transcript increased more in mesophyll cells than in the parenchymatous BS cells. The difference may be caused by different chloroplast structure and posttranscriptional control in mesophyll and BS cells. When similar single-cell samples were assayed for Suc, glucose, and fructan, there was high correlation between 6-SFT gene expression and Suc and glucose concentrations. This is consistent with Suc concentration being the trigger for transcription. Together with earlier demonstrations that the mesophyll cells have a higher sugar threshold for fructan polymerization, our data may indicate separate control of transcription and enzyme activity. Values for the sugar concentrations of the individual cell types are reported.
In vitro platelet quality in storage containers used for pediatric transfusions.
Weiss, Sandra; Scammell, Kenneth; Levin, Elena; Culibrk, Brankica; Zolfaghari, Sima; Gyöngyössy-Issa, Maria I C; Acker, Jason P
2012-08-01
The in vitro quality of small-volume platelet (PLT) aliquots for pediatric transfusions was assessed to determine the best practice approach. Small volumes (50 mL) of single apheresis PLT components (APCs), collected on either CaridianBCT Trima or Haemonetics MCS+ instruments, were aliquoted on Days 2, 3, 4, and 5 postcollection into Fenwal PL1240 or 4R2014 bags or 60-mL polypropylene syringes. Samples were tested for in vitro quality at their recommended expiry times (4 hr for 4R2014 bags and syringes or Day 5 for PL1240 bags). Assays included pH, CD62P expression, and metabolic measures. CD62P expression increased throughout storage in all containers. Among the small-volume containers, pH, pCO(2) , lactate, and bicarbonate varied considerably. Regardless of the day of aliquoting, pCO(2) was significantly higher and pO(2) was significantly lower in gas-impermeable syringes than other containers. No bacterial growth was detected in any sample. The quality of APCs aliquoted into small-volume containers meets regulatory requirements and is generally equivalent to that of full-volume APCs at expiry. © 2012 American Association of Blood Banks.
NASA Astrophysics Data System (ADS)
Best, James P.; Zechner, Johannes; Wheeler, Jeffrey M.; Schoeppner, Rachel; Morstein, Marcus; Michler, Johann
2016-12-01
For the implementation of thin ceramic hard coatings into intensive application environments, the fracture toughness is a particularly important material design parameter. Characterisation of the fracture toughness of small-scale specimens has been a topic of great debate, due to size effects, plasticity, residual stress effects and the influence of ion penetration from the sample fabrication process. In this work, several different small-scale fracture toughness geometries (single-beam cantilever, double-beam cantilever and micro-pillar splitting) were compared, fabricated from a thin physical vapour-deposited ceramic film using a focused ion beam source, and then the effect of the gallium-milled notch on mode I toughness quantification investigated. It was found that notching using a focused gallium source influences small-scale toughness measurements and can lead to an overestimation of the fracture toughness values for chromium nitride (CrN) thin films. The effects of gallium ion irradiation were further studied by performing the first small-scale high-temperature toughness measurements within the scanning electron microscope, with the consequence that annealing at high temperatures allows for diffusion of the gallium to grain boundaries promoting embrittlement in small-scale CrN samples. This work highlights the sensitivity of some materials to gallium ion penetration effects, and the profound effect that it can have on fracture toughness evaluation.
Radio-frequency response of single pores and artificial ion channels
NASA Astrophysics Data System (ADS)
Kim, H. S.; Ramachandran, S.; Stava, E.; van der Weide, D. W.; Blick, R. H.
2011-09-01
Intercellular communication relies on ion channels and pores in cell membranes. These protein-formed channels enable the exchange of ions and small molecules to electrically and/or chemically interact with the cells. Traditionally, recordings on single-ion channels and pores are performed in the dc regime, due to the extremely high impedance of these molecular junctions. This paper is intended as an introduction to radio-frequency (RF) recordings of single-molecule junctions in bilipid membranes. First, we demonstrate how early approaches to using microwave circuitry as readout devices for ion channel formation were realized. The second step will then focus on how to engineer microwave coupling into the high-impedance channel by making use of bio-compatible micro-coaxial lines. We then demonstrate integration of an ultra-broadband microwave circuit for the direct sampling of single α-hemolysin pores in a suspended bilipid membrane. Simultaneous direct current recordings reveal that we can monitor and correlate the RF transmission signal. This enables us to relate the open-close states of the direct current to the RF signal. Altogether, our experiments lay the ground for an RF-readout technique to perform real-time in vitro recordings of pores. The technique thus holds great promise for research and drug screening applications. The possible enhancement of sampling rates of single channels and pores by the large recording bandwidth will allow us to track the passage of single ions.
Liu, Chengtang; Mu, Yujing; Zhang, Chenglong; Zhang, Zhibo; Zhang, Yuanyuan; Liu, Junfeng; Sheng, Jiujiang; Quan, Jiannong
2016-01-04
A liquid nitrogen-free GC-FID system equipped with a single column has been developed for measuring atmospheric C2-C12 hydrocarbons. The system is consisted of a cooling unit, a sampling unit and a separation unit. The cooling unit is used to meet the temperature needs of the sampling unit and the separation unit. The sampling unit includes a dehydration tube and an enrichment tube. No breakthrough of the hydrocarbons was detected when the temperature of the enrichment tube was kept at -90 °C and sampling volume was 400 mL. The separation unit is a small round oven attached on the cooling column. A single capillary column (OV-1, 30 m × 0.32 mm I.D.) was used to separate the hydrocarbons. An optimal program temperature (-60 ∼ 170 °C) of the oven was achieved to efficiently separate C2-C12 hydrocarbons. There were good linear correlations (R(2)=0.993-0.999) between the signals of the hydrocarbons and the enrichment amount of hydrocarbons, and the relative standard deviation (RSD) was less than 5%, and the method detection limits (MDLs) for the hydrocarbons were in the range of 0.02-0.10 ppbv for sampling volume of 400 mL. Field measurements were also conducted and more than 50 hydrocarbons from C2 to C12 were detected in Beijing city. Copyright © 2015 Elsevier B.V. All rights reserved.
Helgerud, M.B.; Waite, W.F.; Kirby, S.H.; Nur, A.
2003-01-01
We report on laboratory measurements of compressional- and shear-wave speeds in a compacted, polycrystalline ice-Ih sample. The sample was made from triply distilled water that had been frozen into single crystal ice, ground into small grains, and sieved to extract the 180250 µm diameter fraction. Porosity was eliminated from the sample by compacting the granular ice between a hydraulically driven piston and a fixed end plug, both containing shear-wave transducers. Based on simultaneous compressional- and shear-wave-speed measurements, we calculated Poisson's ratio and compressional-wave, bulk, and shear moduli from 20 to 5°C and 22 to 33 MPa.
Coplen, T.B.; Wildman, J.D.; Chen, J.
1991-01-01
Improved precision in the H2-H2O equilibration method for ??D analysis has been achieved in an automated system. Reduction in 1-?? standard deviation of a single mass-spectrometer analysis to 1.3??? is achieved by (1) bonding catalyst to glass rods and assigning use to specific equilibration chambers to monitor performance of catalyst, (2) improving the apparatus design, and (3) reducing the H3+ contribution of the mass-spectrometer ion source. For replicate analysis of a water sample, the standard deviation improved to 0.8???. H2S-bearing samples and samples as small as 0.1 mL can be analyzed routinely with this method.
1985-09-01
concepts for large scale radiological defense operations. 2. 212 CP 2 PR0c J 2.1 PLAJWU This project participated in the single shotp A Boy, fired on a...inch diameter by 3 inch high NaI scintilla- tion counter taking sample tubes up to 1-1/4 inches in diameter. -The crystal was mounted on an W type...inch high Nal scin- tillation counter. The crystal -source distance was 8-3/4 inches. Shielding consisted of a lead cylinder 2 inches thick, 7 inches
Molecular kinetics. Ras activation by SOS: allosteric regulation by altered fluctuation dynamics.
Iversen, Lars; Tu, Hsiung-Lin; Lin, Wan-Chen; Christensen, Sune M; Abel, Steven M; Iwig, Jeff; Wu, Hung-Jen; Gureasko, Jodi; Rhodes, Christopher; Petit, Rebecca S; Hansen, Scott D; Thill, Peter; Yu, Cheng-Han; Stamou, Dimitrios; Chakraborty, Arup K; Kuriyan, John; Groves, Jay T
2014-07-04
Activation of the small guanosine triphosphatase H-Ras by the exchange factor Son of Sevenless (SOS) is an important hub for signal transduction. Multiple layers of regulation, through protein and membrane interactions, govern activity of SOS. We characterized the specific activity of individual SOS molecules catalyzing nucleotide exchange in H-Ras. Single-molecule kinetic traces revealed that SOS samples a broad distribution of turnover rates through stochastic fluctuations between distinct, long-lived (more than 100 seconds), functional states. The expected allosteric activation of SOS by Ras-guanosine triphosphate (GTP) was conspicuously absent in the mean rate. However, fluctuations into highly active states were modulated by Ras-GTP. This reveals a mechanism in which functional output may be determined by the dynamical spectrum of rates sampled by a small number of enzymes, rather than the ensemble average. Copyright © 2014, American Association for the Advancement of Science.
A large-scale study of the random variability of a coding sequence: a study on the CFTR gene.
Modiano, Guido; Bombieri, Cristina; Ciminelli, Bianca Maria; Belpinati, Francesca; Giorgi, Silvia; Georges, Marie des; Scotet, Virginie; Pompei, Fiorenza; Ciccacci, Cinzia; Guittard, Caroline; Audrézet, Marie Pierre; Begnini, Angela; Toepfer, Michael; Macek, Milan; Ferec, Claude; Claustres, Mireille; Pignatti, Pier Franco
2005-02-01
Coding single nucleotide substitutions (cSNSs) have been studied on hundreds of genes using small samples (n(g) approximately 100-150 genes). In the present investigation, a large random European population sample (average n(g) approximately 1500) was studied for a single gene, the CFTR (Cystic Fibrosis Transmembrane conductance Regulator). The nonsynonymous (NS) substitutions exhibited, in accordance with previous reports, a mean probability of being polymorphic (q > 0.005), much lower than that of the synonymous (S) substitutions, but they showed a similar rate of subpolymorphic (q < 0.005) variability. This indicates that, in autosomal genes that may have harmful recessive alleles (nonduplicated genes with important functions), genetic drift overwhelms selection in the subpolymorphic range of variability, making disadvantageous alleles behave as neutral. These results imply that the majority of the subpolymorphic nonsynonymous alleles of these genes are selectively negative or even pathogenic.
Hot seeding for the growth of c-axis-oriented Nd-Ba-Cu-O
NASA Astrophysics Data System (ADS)
Chauhan, H. S.; Murakami, M.
2000-06-01
The fabrication of large single-grain RE-Ba-Cu-O (RE denotes rare earth elements) is essential for bulk applications. In the present study, we report on a hot-seeding method for growing Nd-Ba-Cu-O with Nd123 seed crystals. We made an arrangement, in which the Nd123 seed crystal can be transported to the centre of the furnace with a rod through a hole in a rubber cork and insulating stopper. The seed was placed in a small dip made in the rod, which can be turned to drop the seed on the sample. The advantage of this method is that perturbation in the growth conditions such as temperature and oxygen partial pressure can be minimized. Using this method we could grow large single-domain c-axis-oriented samples with the surface area larger than 3 cm×3 cm.
Magnetic Torque in Single Crystal Ni-Mn-Ga
NASA Astrophysics Data System (ADS)
Hobza, Anthony; Müllner, Peter
2017-06-01
Magnetic shape memory alloys deform in an external magnetic field in two distinct ways: by axial straining—known as magnetic-field-induced strain—and by bending when exposed to torque. Here, we examine the magnetic torque that a magnetic field exerts on a long Ni-Mn-Ga rod. A single crystal specimen of Ni-Mn-Ga was constrained with respect to bending and subjected to an external magnetic field. The torque required to rotate the specimen in the field was measured as a function of the orientation of the sample with the external magnetic field, strain, and the magnitude of the external magnetic field. The torque was analyzed based on the changes in the free energy with the angle between the field and the sample. The contributions of magnetocrystalline anisotropy and shape anisotropy to the Zeeman energy determine the net torque. The torque is large when magneotcrystalline and shape anisotropies act synergistically and small when these anisotropies act antagonistically.
Propagation of single-cycle terahertz pulses in random media.
Pearce, J; Mittleman, D M
2001-12-15
We describe what are to our knowledge the first measurements of the propagation of coherent, single-cycle pulses of terahertz radiation in a scattering medium. By measuring the transmission as a function of the length L of the medium, we extract the scattering mean free path l(s)(omega) over a broad bandwidth. We observe variations in l(s) ranging over nearly 2 orders of magnitude and covering the entire thin sample regime from L/l(s)<1 to L/l(s)~10 . We also observe scattering-induced dispersive effects, which can be attributed to the additional path traveled by photons scattered at small angles.
Nikcevic, Irena; Piruska, Aigars; Wehmeyer, Kenneth R; Seliskar, Carl J; Limbach, Patrick A; Heineman, William R
2010-08-01
Parallel separations using CE on a multilane microchip with multiplexed LIF detection is demonstrated. The detection system was developed to simultaneously record data on all channels using an expanded laser beam for excitation, a camera lens to capture emission, and a CCD camera for detection. The detection system enables monitoring of each channel continuously and distinguishing individual lanes without significant crosstalk between adjacent lanes. Multiple analytes can be determined in parallel lanes within a single microchip in a single run, leading to increased sample throughput. The pK(a) determination of small molecule analytes is demonstrated with the multilane microchip.
Nikcevic, Irena; Piruska, Aigars; Wehmeyer, Kenneth R.; Seliskar, Carl J.; Limbach, Patrick A.; Heineman, William R.
2010-01-01
Parallel separations using capillary electrophoresis on a multilane microchip with multiplexed laser induced fluorescence detection is demonstrated. The detection system was developed to simultaneously record data on all channels using an expanded laser beam for excitation, a camera lens to capture emission, and a CCD camera for detection. The detection system enables monitoring of each channel continuously and distinguishing individual lanes without significant crosstalk between adjacent lanes. Multiple analytes can be analyzed on parallel lanes within a single microchip in a single run, leading to increased sample throughput. The pKa determination of small molecule analytes is demonstrated with the multilane microchip. PMID:20737446
Design and performance of a large area neutron sensitive anger camera
Visscher, Theodore; Montcalm, Christopher A.; Donahue, Jr., Cornelius; ...
2015-05-21
We describe the design and performance of a 157mm x 157mm two dimensional neutron detector. The detector uses the Anger principle to determine the position of neutrons. We have verified FWHM resolution of < 1.2mm with distortion < 0.5mm on over 50 installed Anger Cameras. The performance of the detector is limited by the light yield of the scintillator, and it is estimated that the resolution of the current detector could be doubled with a brighter scintillator. Data collected from small (<1mm 3) single crystal reference samples at the single crystal instrument TOPAZ provide results with low R w(F) values
Active doublet method for measuring small changes in physical properties
Roberts, Peter M.; Fehler, Michael C.; Johnson, Paul A.; Phillips, W. Scott
1994-01-01
Small changes in material properties of a work piece are detected by measuring small changes in elastic wave velocity and attenuation within a work piece. Active, repeatable source generate coda wave responses from a work piece, where the coda wave responses are temporally displaced. By analyzing progressive relative phase and amplitude changes between the coda wave responses as a function of elapsed time, accurate determinations of velocity and attenuation changes are made. Thus, a small change in velocity occurring within a sample region during the time periods between excitation origin times (herein called "doublets") will produce a relative delay that changes with elapsed time over some portion of the scattered waves. This trend of changing delay is easier to detect than an isolated delay based on a single arrival and provides a direct measure of elastic wave velocity changes arising from changed material properties of the work piece.
Xu, Fang; Wallace, Robyn C.; Garvin, William; Greenlund, Kurt J.; Bartoli, William; Ford, Derek; Eke, Paul; Town, G. Machell
2016-01-01
Public health researchers have used a class of statistical methods to calculate prevalence estimates for small geographic areas with few direct observations. Many researchers have used Behavioral Risk Factor Surveillance System (BRFSS) data as a basis for their models. The aims of this study were to 1) describe a new BRFSS small area estimation (SAE) method and 2) investigate the internal and external validity of the BRFSS SAEs it produced. The BRFSS SAE method uses 4 data sets (the BRFSS, the American Community Survey Public Use Microdata Sample, Nielsen Claritas population totals, and the Missouri Census Geographic Equivalency File) to build a single weighted data set. Our findings indicate that internal and external validity tests were successful across many estimates. The BRFSS SAE method is one of several methods that can be used to produce reliable prevalence estimates in small geographic areas. PMID:27418213
Kersten, Ellen; Laraia, Barbara; Kelly, Maggi; Adler, Nancy; Yen, Irene H
2012-01-01
Small food stores are prevalent in urban neighborhoods, but the availability of nutritious food at such stores is not well known. The objective of this study was to determine whether data from 3 sources would yield a single, homogenous, healthful food store category that can be used to accurately characterize community nutrition environments for public health research. We conducted in-store surveys in 2009 on store type and the availability of nutritious food in a sample of nonchain food stores (n = 102) in 6 predominantly urban counties in Northern California (Alameda, Contra Costa, Marin, Sacramento, San Francisco, and Santa Clara). We compared survey results with commercial database information and neighborhood sociodemographic data by using independent sample t tests and classification and regression trees. Sampled small food stores yielded a heterogeneous group of stores in terms of store type and nutritious food options. Most stores were identified as convenience (54%) or specialty stores (22%); others were small grocery stores (19%) and large grocery stores (5%). Convenience and specialty stores were smaller and carried fewer nutritious and fresh food items. The availability of nutritious food and produce was better in stores in neighborhoods that had a higher percentage of white residents and a lower population density but did not differ significantly by neighborhood income. Commercial databases alone may not adequately categorize small food stores and the availability of nutritious foods. Alternative measures are needed to more accurately inform research and policies that seek to address disparities in diet-related health conditions.
Laraia, Barbara; Kelly, Maggi; Adler, Nancy; Yen, Irene H.
2012-01-01
Introduction Small food stores are prevalent in urban neighborhoods, but the availability of nutritious food at such stores is not well known. The objective of this study was to determine whether data from 3 sources would yield a single, homogenous, healthful food store category that can be used to accurately characterize community nutrition environments for public health research. Methods We conducted in-store surveys in 2009 on store type and the availability of nutritious food in a sample of nonchain food stores (n = 102) in 6 predominantly urban counties in Northern California (Alameda, Contra Costa, Marin, Sacramento, San Francisco, and Santa Clara). We compared survey results with commercial database information and neighborhood sociodemographic data by using independent sample t tests and classification and regression trees. Results Sampled small food stores yielded a heterogeneous group of stores in terms of store type and nutritious food options. Most stores were identified as convenience (54%) or specialty stores (22%); others were small grocery stores (19%) and large grocery stores (5%). Convenience and specialty stores were smaller and carried fewer nutritious and fresh food items. The availability of nutritious food and produce was better in stores in neighborhoods that had a higher percentage of white residents and a lower population density but did not differ significantly by neighborhood income. Conclusion Commercial databases alone may not adequately categorize small food stores and the availability of nutritious foods. Alternative measures are needed to more accurately inform research and policies that seek to address disparities in diet-related health conditions. PMID:22789445
Creating compact and microscale features in paper-based devices by laser cutting.
Mahmud, Md Almostasim; Blondeel, Eric J M; Kaddoura, Moufeed; MacDonald, Brendan D
2016-11-14
In this work we describe a fabrication method to create compact and microscale features in paper-based microfluidic devices using a CO 2 laser cutting/engraving machine. Using this method we are able to produce the smallest features with the narrowest barriers yet reported for paper-based microfluidic devices. The method uses foil backed paper as the base material and yields inexpensive paper-based devices capable of using small fluid sample volumes and thus small reagent volumes, which is also suitable for mass production. The laser parameters (power and laser head speed) were adjusted to minimize the width of hydrophobic barriers and we were able to create barriers with a width of 39 ± 15 μm that were capable of preventing cross-barrier bleeding. We generated channels with a width of 128 ± 30 μm, which we found to be the physical limit for small features in the chromatography paper we used. We demonstrate how miniaturizing of paper-based microfluidic devices enables eight tests on a single bioassay device using only 2 μL of sample fluid volume.
Marquesan Children's Group Organization Skills as Exhibited in Large-Group Play.
ERIC Educational Resources Information Center
Martini, Mary
This research summary reports on a 4-month long study of 30 children, ages 10-13, who live at the elementary boarding school on the island of 'Ua Pou, Marquesas Island, French Polynesia. Of the sample of 15 boys and 15 girls, 20 of the children are from a single small valley. Follow-up studies also were done of the families of these children. The…
Stochastic detection of enantiomers.
Kang, Xiao-Feng; Cheley, Stephen; Guan, Xiyun; Bayley, Hagan
2006-08-23
The rapid quantification of the enantiomers of small chiral molecules is very important, notably in pharmacology. Here, we show that the enantiomers of drug molecules can be distinguished by stochastic sensing, a single-molecule detection technique. The sensing element is an engineered alpha-hemolysin protein pore, fitted with a beta-cyclodextrin adapter. By using the approach, the enantiomeric composition of samples of ibuprofen and thalidomide can be determined in less than 1 s.
NASA Astrophysics Data System (ADS)
Janzen, Christoph; Fleige, Rüdiger; Noll, Reinhard; Schwenke, Heinrich; Lahmann, Wilhelm; Knoth, Joachim; Beaven, Peter; Jantzen, Eckard; Oest, Andreas; Koke, Peter
2005-08-01
The miniaturization of analytical techniques is a general trend in speciation analytics. We have developed a new analytical technique combining high pressure liquid chromatography (HPLC) with laser-induced breakdown spectroscopy (LIBS). This enables a molecule-specific separation followed by an element-specific analysis of smallest amounts of complex samples. The liquid flow coming from a HPLC pump is transformed into a continuous stream of small droplets (diameter 50-100 μm, volume 65-500 pl) using a piezoelectric pulsed nozzle. After the detection of single droplets with a droplet detector, a Q-switched Nd:YAG Laser is triggered to emit a synchronized laser pulse that irradiates a single droplet. The droplets are evaporated and transformed to the plasma state. The spectrum emitted from the plasma is collected by a spherical mirror and directed through the entrance slit of a Paschen-Runge spectrometer equipped with channel photomultipliers. The spectrometer detects 31 elements simultaneously covering a spectral range from 120 to 589 nm. Purging the measurement chamber with argon enables the detection of vacuum-UV lines. Since the sample is transferred to the plasma state without dilution, very low flow rates in the sub-μl/min range can be realised.
Determination of phosphorus in small amounts of protein samples by ICP-MS.
Becker, J Sabine; Boulyga, Sergei F; Pickhardt, Carola; Becker, J; Buddrus, Stefan; Przybylski, Michael
2003-02-01
Inductively coupled plasma mass spectrometry (ICP-MS) is used for phosphorus determination in protein samples. A small amount of solid protein sample (down to 1 micro g) or digest (1-10 micro L) protein solution was denatured in nitric acid and hydrogen peroxide by closed-microvessel microwave digestion. Phosphorus determination was performed with an optimized analytical method using a double-focusing sector field inductively coupled plasma mass spectrometer (ICP-SFMS) and quadrupole-based ICP-MS (ICP-QMS). For quality control of phosphorus determination a certified reference material (CRM), single cell proteins (BCR 273) with a high phosphorus content of 26.8+/-0.4 mg g(-1), was analyzed. For studies on phosphorus determination in proteins while reducing the sample amount as low as possible the homogeneity of CRM BCR 273 was investigated. Relative standard deviation and measurement accuracy in ICP-QMS was within 2%, 3.5%, 11% and 12% when using CRM BCR 273 sample weights of 40 mg, 5 mg, 1 mg and 0.3 mg, respectively. The lowest possible sample weight for an accurate phosphorus analysis in protein samples by ICP-MS is discussed. The analytical method developed was applied for the analysis of homogeneous protein samples in very low amounts [1-100 micro g of solid protein sample, e.g. beta-casein or down to 1 micro L of protein or digest in solution (e.g., tau protein)]. A further reduction of the diluted protein solution volume was achieved by the application of flow injection in ICP-SFMS, which is discussed with reference to real protein digests after protein separation using 2D gel electrophoresis.The detection limits for phosphorus in biological samples were determined by ICP-SFMS down to the ng g(-1) level. The present work discusses the figure of merit for the determination of phosphorus in a small amount of protein sample with ICP-SFMS in comparison to ICP-QMS.
Liu, Yushan; Ge, Baoming; Abu-Rub, Haitham; ...
2016-06-14
In this study, the active power filter (APF) that consists of a half-bridge leg and an ac capacitor is integrated in the single-phase quasi-Z-source inverter (qZSI) in this paper to avoid the second harmonic power flowing into the dc side. The capacitor of APF buffers the second harmonic power of the load, and the ac capacitor allows highly pulsating ac voltage, so that the capacitances of both dc and ac sides can be small. A model predictive direct power control (DPC) is further proposed to achieve the purpose of this newtopology through predicting the capacitor voltage of APF at eachmore » sampling period and ensuring the APF power to track the second harmonic power of single-phase qZSI. Simulation and experimental results verify the model predictive DPC for the APF-integrated single-phase qZSI.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Yushan; Ge, Baoming; Abu-Rub, Haitham
In this study, the active power filter (APF) that consists of a half-bridge leg and an ac capacitor is integrated in the single-phase quasi-Z-source inverter (qZSI) in this paper to avoid the second harmonic power flowing into the dc side. The capacitor of APF buffers the second harmonic power of the load, and the ac capacitor allows highly pulsating ac voltage, so that the capacitances of both dc and ac sides can be small. A model predictive direct power control (DPC) is further proposed to achieve the purpose of this newtopology through predicting the capacitor voltage of APF at eachmore » sampling period and ensuring the APF power to track the second harmonic power of single-phase qZSI. Simulation and experimental results verify the model predictive DPC for the APF-integrated single-phase qZSI.« less
Magnetic glass-film based on single-nanosize 𝜺 -Fe2O3 nanoparticles
NASA Astrophysics Data System (ADS)
Yoshikiyo, Marie; Namai, Asuka; Nakagawa, Kosuke; Ohkoshi, Shin-ichi
2017-05-01
We report a magnetic thin film of single-nanosize ɛ-Fe2O3 in SiO2 matrix. The glass-film was prepared by sintering a silica coated iron oxide hydroxide on a quartz substrate in air. The glass-film consists of ɛ-Fe2O3 of 8.8 nm size, and its thickness was 570 nm (0.57 μm) with a roughness of 10 nm (0.01 μm). UV-vis spectrum showed that the glass-film has small absorbance of 0.043 at 500 nm. The magneto-optical effect was investigated, and Faraday ellipticity showed a magnetic hysteresis loop with a coercive field of 3.0 ± 0.2 kOe. Furthermore, single-nanosize ɛ-Fe2O3 without silica was prepared as a reference sample, and ferroelectricity was observed. Therefore, the present thin glass-film consists of single-nanosize ferroelectric-ferromagnetic nanoparticles.
Single shot ultrafast dynamic ellipsometry (UDE) of laser-driven shocks in single crystal explosives
DOE Office of Scientific and Technical Information (OSTI.GOV)
Whitley, Von H; Mcgrane, Shawn D; Moore, David S
2009-01-01
We report on the first experiments to measure states in shocked energetic single crystals with dynamic ellipsometry. We demonstrate that these ellipsometric techniques can produce reasonable Hugoniot values using small amounts of crystalline RDX and PETN. Pressures, particle velocities and shock velocities obtained using shocked ellipsometry are comparable to those found using gas-gun flyer plates and molecular dynamics calculations. The adaptation of the technique from uniform thin films of polymers to thick non-perfect crystalline materials was a significant achievement. Correct sample preparation proved to be a crucial component. Through trial and error, we were able to resolve polishing issues, samplemore » quality problems, birefringence effects and mounting difficulties that were not encountered using thin polymer films.« less
Structural and magnetic properties of barium-gadolinium hexaferrites
NASA Astrophysics Data System (ADS)
Litsardakis, G.; Manolakis, I.; Serletis, C.; Efthimiadis, K. G.
A series of Gd-substituted M-type barium hexaferrites has been prepared by the ceramic route, according to the formula (Ba 1-xGd x)O·5.25Fe 2O 3 ( x=0-0.30). XRD analysis revealed that all the samples present primarily an M-type structure. Samples x=0 and x=0.05 are single-phase. Hematite (Fe 2O 3) and GdFeO 3 were detected in the remaining samples. Coercivity ( Hc) shows remarkably high values, ˜293 kA/m for x=0.20 and 0.30 with a maximum of 322 kA/m for x=0.25. Specific saturation magnetization ( σsat) of the samples presents a small increase up to x=0.10. The microstructure examination indicates that Gd may act as a grain growth inhibitor.
Microcrystallography using single-bounce monocapillary optics
Gillilan, R. E.; Cook, M. J.; Cornaby, S. W.; Bilderback, D. H.
2010-01-01
X-ray microbeams have become increasingly valuable in protein crystallography. A number of synchrotron beamlines worldwide have adapted to handling smaller and more challenging samples by providing a combination of high-precision sample-positioning hardware, special visible-light optics for sample visualization, and small-diameter X-ray beams with low background scatter. Most commonly, X-ray microbeams with diameters ranging from 50 µm to 1 µm are produced by Kirkpatrick and Baez mirrors in combination with defining apertures and scatter guards. A simple alternative based on single-bounce glass monocapillary X-ray optics is presented. The basic capillary design considerations are discussed and a practical and robust implementation that capitalizes on existing beamline hardware is presented. A design for mounting the capillary is presented which eliminates parasitic scattering and reduces deformations of the optic to a degree suitable for use on next-generation X-ray sources. Comparison of diffraction data statistics for microcrystals using microbeam and conventional aperture-collimated beam shows that capillary-focused beam can deliver significant improvement. Statistics also confirm that the annular beam profile produced by the capillary optic does not impact data quality in an observable way. Examples are given of new structures recently solved using this technology. Single-bounce monocapillary optics can offer an attractive alternative for retrofitting existing beamlines for microcrystallography. PMID:20157276
Identification of missing variants by combining multiple analytic pipelines.
Ren, Yingxue; Reddy, Joseph S; Pottier, Cyril; Sarangi, Vivekananda; Tian, Shulan; Sinnwell, Jason P; McDonnell, Shannon K; Biernacka, Joanna M; Carrasquillo, Minerva M; Ross, Owen A; Ertekin-Taner, Nilüfer; Rademakers, Rosa; Hudson, Matthew; Mainzer, Liudmila Sergeevna; Asmann, Yan W
2018-04-16
After decades of identifying risk factors using array-based genome-wide association studies (GWAS), genetic research of complex diseases has shifted to sequencing-based rare variants discovery. This requires large sample sizes for statistical power and has brought up questions about whether the current variant calling practices are adequate for large cohorts. It is well-known that there are discrepancies between variants called by different pipelines, and that using a single pipeline always misses true variants exclusively identifiable by other pipelines. Nonetheless, it is common practice today to call variants by one pipeline due to computational cost and assume that false negative calls are a small percent of total. We analyzed 10,000 exomes from the Alzheimer's Disease Sequencing Project (ADSP) using multiple analytic pipelines consisting of different read aligners and variant calling strategies. We compared variants identified by using two aligners in 50,100, 200, 500, 1000, and 1952 samples; and compared variants identified by adding single-sample genotyping to the default multi-sample joint genotyping in 50,100, 500, 2000, 5000 and 10,000 samples. We found that using a single pipeline missed increasing numbers of high-quality variants correlated with sample sizes. By combining two read aligners and two variant calling strategies, we rescued 30% of pass-QC variants at sample size of 2000, and 56% at 10,000 samples. The rescued variants had higher proportions of low frequency (minor allele frequency [MAF] 1-5%) and rare (MAF < 1%) variants, which are the very type of variants of interest. In 660 Alzheimer's disease cases with earlier onset ages of ≤65, 4 out of 13 (31%) previously-published rare pathogenic and protective mutations in APP, PSEN1, and PSEN2 genes were undetected by the default one-pipeline approach but recovered by the multi-pipeline approach. Identification of the complete variant set from sequencing data is the prerequisite of genetic association analyses. The current analytic practice of calling genetic variants from sequencing data using a single bioinformatics pipeline is no longer adequate with the increasingly large projects. The number and percentage of quality variants that passed quality filters but are missed by the one-pipeline approach rapidly increased with sample size.
Impact of spatial variability and sampling design on model performance
NASA Astrophysics Data System (ADS)
Schrape, Charlotte; Schneider, Anne-Kathrin; Schröder, Boris; van Schaik, Loes
2017-04-01
Many environmental physical and chemical parameters as well as species distributions display a spatial variability at different scales. In case measurements are very costly in labour time or money a choice has to be made between a high sampling resolution at small scales and a low spatial cover of the study area or a lower sampling resolution at the small scales resulting in local data uncertainties with a better spatial cover of the whole area. This dilemma is often faced in the design of field sampling campaigns for large scale studies. When the gathered field data are subsequently used for modelling purposes the choice of sampling design and resulting data quality influence the model performance criteria. We studied this influence with a virtual model study based on a large dataset of field information on spatial variation of earthworms at different scales. Therefore we built a virtual map of anecic earthworm distributions over the Weiherbach catchment (Baden-Württemberg in Germany). First of all the field scale abundance of earthworms was estimated using a catchment scale model based on 65 field measurements. Subsequently the high small scale variability was added using semi-variograms, based on five fields with a total of 430 measurements divided in a spatially nested sampling design over these fields, to estimate the nugget, range and standard deviation of measurements within the fields. With the produced maps, we performed virtual samplings of one up to 50 random points per field. We then used these data to rebuild the catchment scale models of anecic earthworm abundance with the same model parameters as in the work by Palm et al. (2013). The results of the models show clearly that a large part of the non-explained deviance of the models is due to the very high small scale variability in earthworm abundance: the models based on single virtual sampling points on average obtain an explained deviance of 0.20 and a correlation coefficient of 0.64. With increasing sampling points per field, we averaged the measured abundance of the sampling within each field to obtain a more representative value of the field average. Doubling the samplings per field strongly improved the model performance criteria (explained deviance 0.38 and correlation coefficient 0.73). With 50 sampling points per field the performance criteria were 0.91 and 0.97 respectively for explained deviance and correlation coefficient. The relationship between number of samplings and performance criteria can be described with a saturation curve. Beyond five samples per field the model improvement becomes rather small. With this contribution we wish to discuss the impact of data variability at sampling scale on model performance and the implications for sampling design and assessment of model results as well as ecological inferences.
Sved, J A; Yu, H; Dominiak, B; Gilchrist, A S
2003-02-01
Long-range dispersal of a species may involve either a single long-distance movement from a core population or spreading via unobserved intermediate populations. Where the new populations originate as small propagules, genetic drift may be extreme and gene frequency or assignment methods may not prove useful in determining the relation between the core population and outbreak samples. We describe computationally simple resampling methods for use in this situation to distinguish between the different modes of dispersal. First, estimates of heterozygosity can be used to test for direct sampling from the core population and to estimate the effective size of intermediate populations. Second, a test of sharing of alleles, particularly rare alleles, can show whether outbreaks are related to each other rather than arriving as independent samples from the core population. The shared-allele statistic also serves as a genetic distance measure that is appropriate for small samples. These methods were applied to data on a fruit fly pest species, Bactrocera tryoni, which is quarantined from some horticultural areas in Australia. We concluded that the outbreaks in the quarantine zone came from a heterogeneous set of genetically differentiated populations, possibly ones that overwinter in the vicinity of the quarantine zone.
Legras, Antoine; Barritault, Marc; Tallet, Anne; Fabre, Elizabeth; Guyard, Alice; Rance, Bastien; Digan, William; Pecuchet, Nicolas; Giroux-Leprieur, Etienne; Julie, Catherine; Jouveshomme, Stéphane; Duchatelle, Véronique; Giraudet, Véronique; Gibault, Laure; Cazier, Alain; Pastre, Jean; Le Pimpec-Barthes, Françoise; Laurent-Puig, Pierre; Blons, Hélène
2018-05-19
Theranostic assays are based on single-gene testing, but the ability of next-generation sequencing (NGS) to interrogate numerous genetic alterations will progressively replace single-gene assays. Although NGS was evaluated to screen for theranostic mutations, its usefulness in clinical practice on large series of samples remains to be demonstrated. NGS performance was assessed following guidelines. TaqMan probes and NGS were compared for their ability to detect EGFR and KRAS mutations, and NGS mutation profiles were analyzed on a large series of non-small-cell lung cancers (n = 1343). The R 2 correlation between expected and measured allelic ratio, using commercial samples, was >0.96. Mutation detection threshold was 2% for 10 ng of DNA input. κ Scores for TaqMan versus NGS were 0.99 (95% CI, 0.97-1.00) for EGFR and 0.98 (95% CI, 0.97-1.00) for KRAS after exclusion of rare EGFR (n = 40) and KRAS (n = 60) mutations. NGS identified 693 and 292 mutations in validated and potential oncogenic drivers, respectively. Significant associations were found between EGFR and PI3KCA or CTNNB1 and between KRAS and STK11. Potential oncogenic driver mutations or gene amplifications were more frequent in validated oncogenic driver nonmutated samples. This work is a proof of concept that targeted NGS is accessible in routine screening, including large screening, at reasonable cost. Clinical data should be collected and implemented in specific databases to make molecular data meaningful for direct patients' benefit. Copyright © 2018. Published by Elsevier Inc.
Geist, Kamile; Hitchcock, John H
2014-01-01
The profession would benefit from greater and routine generation of causal evidence pertaining to the impact of music therapy interventions on client outcomes. One way to meet this goal is to revisit the use of Single Case Designs (SCDs) in clinical practice and research endeavors in music therapy. Given the appropriate setting and goals, this design can be accomplished with small sample sizes and it is often appropriate for studying music therapy interventions. In this article, we promote and discuss implementation of SCD studies in music therapy settings, review the meaning of internal study validity and by extension the notion of causality, and describe two of the most commonly used SCDs to demonstrate how they can help generate causal evidence to inform the field. In closing, we describe the need for replication and future meta-analysis of SCD studies completed in music therapy settings. SCD studies are both feasible and appropriate for use in music therapy clinical practice settings, particularly for testing effectiveness of interventions for individuals or small groups. © the American Music Therapy Association 2014. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Saha-Shah, Anumita; Weber, Anna E.; Karty, Jonathan A.; Ray, Steven J.; Hieftje, Gary M.
2015-01-01
Nanopipettes (pipettes with diameters <1 μm) were explored as pressure-driven fluid manipulation tools for sampling nanoliter volumes of fluids. The fundamental behavior of fluids confined in the narrow channels of the nanopipette shank was studied to optimize sampling volume and probe geometry. This method was utilized to collect nanoliter volumes (<10 nL) of sample from single Allium cepa cells and live Drosophila melanogaster first instar larvae. Matrix assisted laser desorption/ionization-mass spectrometry (MALDI-MS) was utilized to characterize the collected sample. The use of nanopipettes for surface sampling of mouse brain tissue sections was also explored. Lipid analyses were performed on mouse brain tissues with spatial resolution of sampling as small as 50 μm. Nanopipettes were shown to be a versatile tool that will find further application in studies of sample heterogeneity and population analysis for a wide range of samples. PMID:28706697
Dual-modality imaging of function and physiology
NASA Astrophysics Data System (ADS)
Hasegawa, Bruce H.; Iwata, Koji; Wong, Kenneth H.; Wu, Max C.; Da Silva, Angela; Tang, Hamilton R.; Barber, William C.; Hwang, Andrew B.; Sakdinawat, Anne E.
2002-04-01
Dual-modality imaging is a technique where computed tomography or magnetic resonance imaging is combined with positron emission tomography or single-photon computed tomography to acquire structural and functional images with an integrated system. The data are acquired during a single procedure with the patient on a table viewed by both detectors to facilitate correlation between the structural and function images. The resulting data can be useful for localization for more specific diagnosis of disease. In addition, the anatomical information can be used to compensate the correlated radionuclide data for physical perturbations such as photon attenuation, scatter radiation, and partial volume errors. Thus, dual-modality imaging provides a priori information that can be used to improve both the visual quality and the quantitative accuracy of the radionuclide images. Dual-modality imaging systems also are being developed for biological research that involves small animals. The small-animal dual-modality systems offer advantages for measurements that currently are performed invasively using autoradiography and tissue sampling. By acquiring the required data noninvasively, dual-modality imaging has the potential to allow serial studies in a single animal, to perform measurements with fewer animals, and to improve the statistical quality of the data.
Bilgic, Huseyin Bilgin; Bakırcı, Serkan; Kose, Onur; Unlu, Ahmet Hakan; Hacılarlıoglu, Selin; Eren, Hasan; Weir, William; Karagenc, Tulin
2017-04-27
Tick-borne haemoparasitic diseases (TBHDs), caused by Theileria, Babesia, Anaplasma and Ehrlichia, are common in regions of the world where the distributions of host, pathogen and vector overlap. Many of these diseases threaten livestock production and some also represent a concern to human public health. The primary aim of this study was to determine the prevalence of the above-mentioned pathogens in a large number of blood samples (n = 1979) collected from sheep (n = 1727) and goats (n = 252) in Turkey. A secondary aim was to assess the diagnostic sensitivity of a number of species-specific polymerase chain reaction (PCR) tests and the reverse line blotting (RLB) assay. DNA samples were screened using species-specific PCR for the presence of Theileria ovis, Theileria sp. MK, T. lestoquardi, T. uilenbergi, T. luwenshuni, Babesia ovis, Anaplasma ovis and A. phagocytophilum while RLB was undertaken to test for the presence of all known Theileria, Babesia, Anaplasma and Ehrlichia species. The diagnostic sensitivity of these two approaches was then compared in terms of their ability to detect single species and mixed infections. Overall, 84 and 74.43% of the small ruminants sampled were identified as hosting one or more pathogen(s) by species-specific PCR and RLB respectively. The presence of Theileria sp. OT1, T. luwenshuni and T. uilenbergi in Turkey was revealed for the first time while the presence of Babesia motasi, B. crassa and T. separata in Turkish small ruminants was confirmed using molecular methods. A high prevalence of mixed infection was evident, with PCR and RLB approaches indicating that 52.24 and 35.42% of animals were co-infected with multiple species, respectively. More than 80% of the mixed infections contained T. ovis and/or A. ovis. The RLB approach was found to be capable of detecting mixed infections with species such as Theileria sp. OT1, Theileria sp. OT3, T. separata, B. crassa and Babesia spp. The results indicated that pathogens causing TBHDs are highly prevalent in sheep and goats in Turkey. The diagnostic sensitivity of species-specific single PCR was generally higher than that of RLB. However, the latter approach was still capable of identifying a high proportion of individuals containing mixed-species infections. The use of species-specific single PCR is recommended to accurately estimate pathogen prevalence and to identify co-infected hosts.
Reducing the number of reconstructions needed for estimating channelized observer performance
NASA Astrophysics Data System (ADS)
Pineda, Angel R.; Miedema, Hope; Brenner, Melissa; Altaf, Sana
2018-03-01
A challenge for task-based optimization is the time required for each reconstructed image in applications where reconstructions are time consuming. Our goal is to reduce the number of reconstructions needed to estimate the area under the receiver operating characteristic curve (AUC) of the infinitely-trained optimal channelized linear observer. We explore the use of classifiers which either do not invert the channel covariance matrix or do feature selection. We also study the assumption that multiple low contrast signals in the same image of a non-linear reconstruction do not significantly change the estimate of the AUC. We compared the AUC of several classifiers (Hotelling, logistic regression, logistic regression using Firth bias reduction and the least absolute shrinkage and selection operator (LASSO)) with a small number of observations both for normal simulated data and images from a total variation reconstruction in magnetic resonance imaging (MRI). We used 10 Laguerre-Gauss channels and the Mann-Whitney estimator for AUC. For this data, our results show that at small sample sizes feature selection using the LASSO technique can decrease bias of the AUC estimation with increased variance and that for large sample sizes the difference between these classifiers is small. We also compared the use of multiple signals in a single reconstructed image to reduce the number of reconstructions in a total variation reconstruction for accelerated imaging in MRI. We found that AUC estimation using multiple low contrast signals in the same image resulted in similar AUC estimates as doing a single reconstruction per signal leading to a 13x reduction in the number of reconstructions needed.
Laboratory Measurements of Single-Particle Polarimetric Spectrum
NASA Astrophysics Data System (ADS)
Gritsevich, M.; Penttila, A.; Maconi, G.; Kassamakov, I.; Helander, P.; Puranen, T.; Salmi, A.; Hæggström, E.; Muinonen, K.
2017-12-01
Measuring scattering properties of different targets is important for material characterization, remote sensing applications, and for verifying theoretical results. Furthermore, there are usually simplifications made when we model targets and compute the scattering properties, e.g., ideal shape or constant optical parameters throughout the target material. Experimental studies help in understanding the link between the observed properties and computed results. Experimentally derived Mueller matrices of studied particles can be used as input for larger-scale scattering simulations, e.g., radiative transfer computations. This method allows to bypass the problem of using an idealized model for single-particle optical properties. While existing approaches offer ensemble- and orientation-averaged particle properties, our aim is to measure individual particles with controlled or known orientation. With the newly developed scatterometer, we aim to offer novel possibility to measure single, small (down to μm-scale) targets and their polarimetric spectra. This work presents an experimental setup that measures light scattered by a fixed small particle with dimensions ranging between micrometer and millimeter sizes. The goal of our setup is nondestructive characterization of such particles by measuring light of multiple wavelengths scattered in 360° in a horizontal plane by an ultrasonically levitating sample, whilst simultaneously controlling its 3D position and orientation. We describe the principles and design of our instrument and its calibration. We also present example measurements of real samples. This study was conducted under the support from the European Research Council, in the frame of the Advanced Grant project No. 320773 `Scattering and Absorption of Electromagnetic Waves in Particulate Media' (SAEMPL).
Sahajpal, Vivek; Goyal, S P
2010-06-01
The exhibits obtained in wildlife offence cases quite often present a challenging situation for the forensic expert. The selection of proper approach for analysis is vital for a successful analysis. A generalised forensic analysis approach should proceed from the use of non-destructive techniques (morphological and microscopic examination) to partially destructive and finally destructive techniques (DNA analysis). The findings of non-destructive techniques may sometime be inconclusive but they definitely help in steering further forensic analysis in a proper direction. We describe a recent case where a very small dried skin piece (<0.05 mg) with just one small trimmed guard hair (0.4 cm) on it was received for species identification. The single guard hair was examined microscopically to get an indication of the type of species. We also describe the extraction procedure with a lower amount of sample, using an automated extraction method (Qiagen Biorobot EZ1) and PCR amplification of three mitochondrial genes (16s rRNA, 12s rRNA and cytochrome b) for species identification. Microscopic examination of the single hair indicated a viverrid species but the initial DNA analysis with 16s rRNA (through NCBI BLAST) showed the highest homology (93%) with a hyaenid species (Hyaena hyaena). However, further DNA analysis based on 12s rRNA and cytochrome b gene proved that the species was indeed a viverrid i.e. Viverricula indica (small Indian civet). The highest homology shown with a Hyaenid species by the 16s rRNA sequence from the case sample was due to lack of a 16s rRNA sequence for Viverricula indica in the NCBI data base. The case highlights the importance of morphological and microscopic examinations in wildlife offence cases. With respect to DNA extraction technology we found that automatic extraction method of Biorobot EZ1 (Qiagen) is quite useful with less amount of sample (much below recommended amount). Copyright 2009 Forensic Science Society. Published by Elsevier Ireland Ltd. All rights reserved.
Trefz, Phillip; Rösner, Lisa; Hein, Dietmar; Schubert, Jochen K; Miekisch, Wolfram
2013-04-01
Needle trap devices (NTDs) have shown many advantages such as improved detection limits, reduced sampling time and volume, improved stability, and reproducibility if compared with other techniques used in breath analysis such as solid-phase extraction and solid-phase micro-extraction. Effects of sampling flow (2-30 ml/min) and volume (10-100 ml) were investigated in dry gas standards containing hydrocarbons, aldehydes, and aromatic compounds and in humid breath samples. NTDs contained (single-bed) polymer packing and (triple-bed) combinations of divinylbenzene/Carbopack X/Carboxen 1000. Substances were desorbed from the NTDs by means of thermal expansion and analyzed by gas chromatography-mass spectrometry. An automated CO2-controlled sampling device for direct alveolar sampling at the point-of-care was developed and tested in pilot experiments. Adsorption efficiency for small volatile organic compounds decreased and breakthrough increased when sampling was done with polymer needles from a water-saturated matrix (breath) instead from dry gas. Humidity did not affect analysis with triple-bed NTDs. These NTDs showed only small dependencies on sampling flow and low breakthrough from 1-5 %. The new sampling device was able to control crucial parameters such as sampling flow and volume. With triple-bed NTDs, substance amounts increased linearly with increasing sample volume when alveolar breath was pre-concentrated automatically. When compared with manual sampling, automatic sampling showed comparable or better results. Thorough control of sampling and adequate choice of adsorption material is mandatory for application of needle trap micro-extraction in vivo. The new CO2-controlled sampling device allows direct alveolar sampling at the point-of-care without the need of any additional sampling, storage, or pre-concentration steps.
Sitt, Amit; Hess, Henry
2015-05-13
Nanoscale detectors hold great promise for single molecule detection and the analysis of small volumes of dilute samples. However, the probability of an analyte reaching the nanosensor in a dilute solution is extremely low due to the sensor's small size. Here, we examine the use of a chemical potential gradient along a surface to accelerate analyte capture by nanoscale sensors. Utilizing a simple model for transport induced by surface binding energy gradients, we study the effect of the gradient on the efficiency of collecting nanoparticles and single and double stranded DNA. The results indicate that chemical potential gradients along a surface can lead to an acceleration of analyte capture by several orders of magnitude compared to direct collection from the solution. The improvement in collection is limited to a relatively narrow window of gradient slopes, and its extent strongly depends on the size of the gradient patch. Our model allows the optimization of gradient layouts and sheds light on the fundamental characteristics of chemical potential gradient induced transport.
Monitoring the vernal advancement and retrogradation (green wave effect) of natural vegetation
NASA Technical Reports Server (NTRS)
Rouse, J. W., Jr. (Principal Investigator)
1973-01-01
The author has identified the following significant results. Preliminary evaluation of autumnal phase ground truth data suggests that the sampling procedures at the Great Plains Corridor network test sites are adequate to show relatively small temporal changes in above-ground vegetation biomass and vegetation condition. Vegetation changes measured August through December, reflect grazing intensity and environmental conditions at the test sites. Preliminary analysis of black and white imagery suggests that detail in vegetation patterns is much greater than originally anticipated. A first look analysis of single band imagery and digital data at two locations shows that woodland, grassland, and cropland areas are easily delineated. Computer derived grey-scale maps from MSS digital data were shown to be useful in identifying the location of small fields and features of the natural and cultivated lands. Single band imagery and digital data are believed to have important application for synoptic land use mapping and inventory. Initial ratio analysis, using band 5 and 7 data, suggests the applicability in the greenness of a vegetative scene.
NASA Astrophysics Data System (ADS)
Jedamzik, Ralf; Westerhoff, Thomas
2017-09-01
The coefficient of thermal expansion (CTE) and its spatial homogeneity from small to large formats is the most important property of ZERODUR. Since more than a decade SCHOTT has documented the excellent CTE homogeneity. It started with reviews of past astronomical telescope projects like the VLT, Keck and GTC mirror blanks and continued with dedicated evaluations of the production. In recent years, extensive CTE measurements on samples cut from randomly selected single ZERODUR parts in meter size and formats of arbitrary shape, large production boules and even 4 m sized blanks have demonstrated the excellent CTE homogeneity in production. The published homogeneity data shows single ppb/K peak to valley CTE variations on medium spatial scale of several cm down to small spatial scale of only a few mm mostly at the limit of the measurement reproducibility. This review paper summarizes the results also in respect to the increased CTE measurement accuracy over the last decade of ZERODUR production.
Iles, Ray K; Cole, Laurence A; Butler, Stephen A
2014-06-05
The analysis of human chorionic gonadotropin (hCG) in clinical chemistry laboratories by specific immunoassay is well established. However, changes in glycosylation are not as easily assayed and yet alterations in hCG glycosylation is associated with abnormal pregnancy. hCGβ-core fragment (hCGβcf) was isolated from the urine of women, pregnant with normal, molar and hyperemesis gravidarum pregnancies. Each sample was subjected to matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI TOF MS) analysis following dithiothreitol (DTT) reduction and fingerprint spectra of peptide hCGβ 6-40 were analyzed. Samples were variably glycosylated, where most structures were small, core and largely mono-antennary. Larger single bi-antennary and mixtures of larger mono-antennary and bi-antennary moieties were also observed in some samples. Larger glycoforms were more abundant in the abnormal pregnancies and tri-antennary carbohydrate moieties were only observed in the samples from molar and hyperemesis gravidarum pregnancies. Given that such spectral profiling differences may be characteristic, development of small sample preparation for mass spectral analysis of hCG may lead to a simpler and faster approach to glycostructural analysis and potentially a novel clinical diagnostic test.
Bentzen, Amalie Kai; Marquard, Andrea Marion; Lyngaa, Rikke; Saini, Sunil Kumar; Ramskov, Sofie; Donia, Marco; Such, Lina; Furness, Andrew J S; McGranahan, Nicholas; Rosenthal, Rachel; Straten, Per Thor; Szallasi, Zoltan; Svane, Inge Marie; Swanton, Charles; Quezada, Sergio A; Jakobsen, Søren Nyboe; Eklund, Aron Charles; Hadrup, Sine Reker
2016-10-01
Identification of the peptides recognized by individual T cells is important for understanding and treating immune-related diseases. Current cytometry-based approaches are limited to the simultaneous screening of 10-100 distinct T-cell specificities in one sample. Here we use peptide-major histocompatibility complex (MHC) multimers labeled with individual DNA barcodes to screen >1,000 peptide specificities in a single sample, and detect low-frequency CD8 T cells specific for virus- or cancer-restricted antigens. When analyzing T-cell recognition of shared melanoma antigens before and after adoptive cell therapy in melanoma patients, we observe a greater number of melanoma-specific T-cell populations compared with cytometry-based approaches. Furthermore, we detect neoepitope-specific T cells in tumor-infiltrating lymphocytes and peripheral blood from patients with non-small cell lung cancer. Barcode-labeled pMHC multimers enable the combination of functional T-cell analysis with large-scale epitope recognition profiling for the characterization of T-cell recognition in various diseases, including in small clinical samples.
Multicategory nets of single-layer perceptrons: complexity and sample-size issues.
Raudys, Sarunas; Kybartas, Rimantas; Zavadskas, Edmundas Kazimieras
2010-05-01
The standard cost function of multicategory single-layer perceptrons (SLPs) does not minimize the classification error rate. In order to reduce classification error, it is necessary to: 1) refuse the traditional cost function, 2) obtain near to optimal pairwise linear classifiers by specially organized SLP training and optimal stopping, and 3) fuse their decisions properly. To obtain better classification in unbalanced training set situations, we introduce the unbalance correcting term. It was found that fusion based on the Kulback-Leibler (K-L) distance and the Wu-Lin-Weng (WLW) method result in approximately the same performance in situations where sample sizes are relatively small. The explanation for this observation is by theoretically known verity that an excessive minimization of inexact criteria becomes harmful at times. Comprehensive comparative investigations of six real-world pattern recognition (PR) problems demonstrated that employment of SLP-based pairwise classifiers is comparable and as often as not outperforming the linear support vector (SV) classifiers in moderate dimensional situations. The colored noise injection used to design pseudovalidation sets proves to be a powerful tool for facilitating finite sample problems in moderate-dimensional PR tasks.
A modified Wald interval for the area under the ROC curve (AUC) in diagnostic case-control studies
2014-01-01
Background The area under the receiver operating characteristic (ROC) curve, referred to as the AUC, is an appropriate measure for describing the overall accuracy of a diagnostic test or a biomarker in early phase trials without having to choose a threshold. There are many approaches for estimating the confidence interval for the AUC. However, all are relatively complicated to implement. Furthermore, many approaches perform poorly for large AUC values or small sample sizes. Methods The AUC is actually a probability. So we propose a modified Wald interval for a single proportion, which can be calculated on a pocket calculator. We performed a simulation study to compare this modified Wald interval (without and with continuity correction) with other intervals regarding coverage probability and statistical power. Results The main result is that the proposed modified Wald intervals maintain and exploit the type I error much better than the intervals of Agresti-Coull, Wilson, and Clopper-Pearson. The interval suggested by Bamber, the Mann-Whitney interval without transformation and also the interval of the binormal AUC are very liberal. For small sample sizes the Wald interval with continuity has a comparable coverage probability as the LT interval and higher power. For large sample sizes the results of the LT interval and of the Wald interval without continuity correction are comparable. Conclusions If individual patient data is not available, but only the estimated AUC and the total sample size, the modified Wald intervals can be recommended as confidence intervals for the AUC. For small sample sizes the continuity correction should be used. PMID:24552686
A modified Wald interval for the area under the ROC curve (AUC) in diagnostic case-control studies.
Kottas, Martina; Kuss, Oliver; Zapf, Antonia
2014-02-19
The area under the receiver operating characteristic (ROC) curve, referred to as the AUC, is an appropriate measure for describing the overall accuracy of a diagnostic test or a biomarker in early phase trials without having to choose a threshold. There are many approaches for estimating the confidence interval for the AUC. However, all are relatively complicated to implement. Furthermore, many approaches perform poorly for large AUC values or small sample sizes. The AUC is actually a probability. So we propose a modified Wald interval for a single proportion, which can be calculated on a pocket calculator. We performed a simulation study to compare this modified Wald interval (without and with continuity correction) with other intervals regarding coverage probability and statistical power. The main result is that the proposed modified Wald intervals maintain and exploit the type I error much better than the intervals of Agresti-Coull, Wilson, and Clopper-Pearson. The interval suggested by Bamber, the Mann-Whitney interval without transformation and also the interval of the binormal AUC are very liberal. For small sample sizes the Wald interval with continuity has a comparable coverage probability as the LT interval and higher power. For large sample sizes the results of the LT interval and of the Wald interval without continuity correction are comparable. If individual patient data is not available, but only the estimated AUC and the total sample size, the modified Wald intervals can be recommended as confidence intervals for the AUC. For small sample sizes the continuity correction should be used.
Genetic diversity of small eukaryotes in lakes differing by their trophic status.
Lefranc, Marie; Thénot, Aurélie; Lepère, Cécile; Debroas, Didier
2005-10-01
Small eukaryotes, cells with a diameter of less than 5 mum, are fundamental components of lacustrine planktonic systems. In this study, small-eukaryote diversity was determined by sequencing cloned 18S rRNA genes in three libraries from lakes of differing trophic status in the Massif Central, France: the oligotrophic Lake Godivelle, the oligomesotrophic Lake Pavin, and the eutrophic Lake Aydat. This analysis shows that the least diversified library was in the eutrophic lake (12 operational taxonomic units [OTUs]) and the most diversified was in the oligomesotrophic lake (26 OTUs). Certain groups were present in at least two ecosystems, while the others were specific to one lake on the sampling date. Cryptophyta, Chrysophyceae, and the strictly heterotrophic eukaryotes, Ciliophora and fungi, were identified in the three libraries. Among the small eukaryotes found only in two lakes, Choanoflagellida and environmental sequences (LKM11) were not detected in the eutrophic system whereas Cercozoa were confined to the oligomesotrophic and eutrophic lakes. Three OTUs, linked to the Perkinsozoa, were detected only in the Aydat library, where they represented 60% of the clones of the library. Chlorophyta and Haptophyta lineages were represented by a single clone and were present only in Godivelle and Pavin, respectively. Of the 127 clones studied, classical pigmented organisms (autotrophs and mixotrophs) represented only a low proportion regardless of the library's origin. This study shows that the small-eukaryote community composition may differ as a function of trophic status; certain lineages could be detected only in a single ecosystem.
Reduced Iron Sulfide Systems for Removal of Heavy Metal Ions from Groundwater
2009-07-01
be gleaned from higher magnification of these samples. Each set of lattice fringes represents a single crystal of mackinawite (Ohfuji and Ricard...diffractograms, the diffraction peaks are broad and weak, indicating a poor degree of crystallization or a small crystallite size. For the non-magnetic...the lattice spacings of synthetic mackinawite in this study are shorter. The 3-day aging in this study resulted in a higher degree of crystallization
Diel Variation in Beaked Whale Diving Behavior
2008-01-01
While our results are only from a single study area and our sample size is small, diving patterns of these two species appear very stereotypic ...sharks of the genus Isistius (McSweeney et al. 2007). Cookie-cutter sharks are thought to exhibit diel vertical migrations, spending time near the...Mar. Mamm. Sci. 23: 666-687. 17 Mead, J.G. 1989. Beaked whales of the genus Mesoplodon. Pages 349-430 In S.H. Ridgway and R. Harrison
Estimation of Tumor Angiogenesis With Contrast Enhanced Subharmonic Ultrasound Imaging
2005-07-01
measure the FBV as a function of time (Fig. 1). The setup consists of a pair of confocally positioned broadband focused transducers (diameter: 2.54 cm...signals only come from the microbubbles in the small confocal region of the two transducers (1-4 mm3 for 2 MHz transmission). The sampling frequency...amplified and then supplied to a single-element broadband focused transducer. Another broadband focused transducer ( confocally positioned to the first
Eichorst, Stephanie A.; Strasser, Florian; Woyke, Tanja; ...
2015-08-31
The combined approach of incubating environmental samples with stable isotope-labeled substrates followed by single-cell analyses through high-resolution secondary ion mass spectrometry (NanoSIMS) or Raman microspectroscopy provides insights into the in situ function of microorganisms. This approach has found limited application in soils presumably due to the dispersal of microbial cells in a large background of particles. We developed a pipeline for the efficient preparation of cell extracts from soils for subsequent single-cell methods by combining cell detachment with separation of cells and soil particles followed by cell concentration. The procedure was evaluated by examining its influence on cell recoveries andmore » microbial community composition across two soils. This approach generated a cell fraction with considerably reduced soil particle load and of sufficient small size to allow single-cell analysis by NanoSIMS, as shown when detecting active N2-fixing and cellulose-responsive microorganisms via 15N2 and 13C-UL-cellulose incubations, respectively. The same procedure was also applicable for Raman microspectroscopic analyses of soil microorganisms, assessed via microcosm incubations with a 13C-labeled carbon source and deuterium oxide (D2O, a general activity marker). Lastly, the described sample preparation procedure enables single-cell analysis of soil microorganisms using NanoSIMS and Raman microspectroscopy, but should also facilitate single-cell sorting and sequencing.« less
Huang, Yong; Yang, Qiyun; Yoon, Kwangchae; Lei, Yovnne; Shi, Robert; Gee, Winnie; Lin, Emil T.; Greenblatt, Ruth M.; Gandhi, Monica
2012-01-01
Sufficient drug exposure is crucial for maintaining durable responses to HIV treatments. However, monitoring drug exposure using single blood samples only provides short-term information and is highly subject to intra-individual pharmacokinetic variation. Drugs can accumulate in hair over a long period of time, so hair drug levels can provide drug exposure information over prolonged periods. We now report on a specific, sensitive and reproducible LC-MS/MS method for measuring nevirapine (NVP), a widely used antiretroviral drug, levels in human hair using even a single short strand of hair. Hair samples are cut into small segments and drug is extracted in methanol/trifluoroacetic acid (v/v, 9:1) shaken at 37°C in a water bath overnight, followed by liquid-liquid extraction under alkaline conditions. The extracted samples are then separated on a BDS-C18 column with mobile phase composed as 50% acetonitrile containing 0.15% acetic acid and 4 mM ammonium acetate with an isocratic elution for a total run time of 3 min. and detected by triple quadrupole electrospray multiple reaction mode at precursor/product ion at 267.0>225.9 m/z. Deuterated nevirapine-d5 was used as internal standard. This method was validated from 0.25 to 100 ng/mg using 2 mg hair samples. The accuracies for spiked NVP hair control samples were 98–106% with coefficients of variation (CV) less than 10%. The CV for incurred hair control samples was less than 7%. The extraction efficiency for incurred control hair samples was estimated at more than 95% by repeated extractions. This method has been successfully applied to analyze more than 1000 hair samples from participants in a large ongoing cohort study of HIV-infected participants. We also showed that nevirapine in human hair can easily be detected in a single short strand of hair. This method will allow us to identify drug non-adherence using even a single strand of hair. PMID:21847531
The kilometer-sized Main Belt asteroid population revealed by Spitzer
NASA Astrophysics Data System (ADS)
Ryan, E. L.; Mizuno, D. R.; Shenoy, S. S.; Woodward, C. E.; Carey, S. J.; Noriega-Crespo, A.; Kraemer, K. E.; Price, S. D.
2015-06-01
Aims: Multi-epoch Spitzer Space Telescope 24 μm data is utilized from the MIPSGAL and Taurus Legacy surveys to detect asteroids based on their relative motion. Methods: Infrared detections are matched to known asteroids and average diameters and albedos are derived using the near Earth asteroid thermal model (NEATM) for 1865 asteroids ranging in size from 0.2 to 169 km. A small subsample of these objects was also detected by IRAS or MSX and the single wavelength albedo and diameter fits derived from these data are within the uncertainties of the IRAS and/or MSX derived albedos and diameters and available occultation diameters, which demonstrates the robustness of our technique. Results: The mean geometric albedo of the small Main Belt asteroids in this sample is pV = 0.134 with a sample standard deviation of 0.106. The albedo distribution of this sample is far more diverse than the IRAS or MSX samples. The cumulative size-frequency distribution of asteroids in the Main Belt at small diameters is directly derived and a 3σ deviation from the fitted size-frequency distribution slope is found near 8 km. Completeness limits of the optical and infrared surveys are discussed. Tables 1-3 are only available at the CDS via anonymous ftp to http://cdsarc.u-strasbg.fr (ftp://130.79.128.5) or via http://cdsarc.u-strasbg.fr/viz-bin/qcat?J/A+A/578/A42
Wright, Mark H.; Tung, Chih-Wei; Zhao, Keyan; Reynolds, Andy; McCouch, Susan R.; Bustamante, Carlos D.
2010-01-01
Motivation: The development of new high-throughput genotyping products requires a significant investment in testing and training samples to evaluate and optimize the product before it can be used reliably on new samples. One reason for this is current methods for automated calling of genotypes are based on clustering approaches which require a large number of samples to be analyzed simultaneously, or an extensive training dataset to seed clusters. In systems where inbred samples are of primary interest, current clustering approaches perform poorly due to the inability to clearly identify a heterozygote cluster. Results: As part of the development of two custom single nucleotide polymorphism genotyping products for Oryza sativa (domestic rice), we have developed a new genotype calling algorithm called ‘ALCHEMY’ based on statistical modeling of the raw intensity data rather than modelless clustering. A novel feature of the model is the ability to estimate and incorporate inbreeding information on a per sample basis allowing accurate genotyping of both inbred and heterozygous samples even when analyzed simultaneously. Since clustering is not used explicitly, ALCHEMY performs well on small sample sizes with accuracy exceeding 99% with as few as 18 samples. Availability: ALCHEMY is available for both commercial and academic use free of charge and distributed under the GNU General Public License at http://alchemy.sourceforge.net/ Contact: mhw6@cornell.edu Supplementary information: Supplementary data are available at Bioinformatics online. PMID:20926420
Accelerated 2D magnetic resonance spectroscopy of single spins using matrix completion
NASA Astrophysics Data System (ADS)
Scheuer, Jochen; Stark, Alexander; Kost, Matthias; Plenio, Martin B.; Naydenov, Boris; Jelezko, Fedor
2015-12-01
Two dimensional nuclear magnetic resonance (NMR) spectroscopy is one of the major tools for analysing the chemical structure of organic molecules and proteins. Despite its power, this technique requires long measurement times, which, particularly in the recently emerging diamond based single molecule NMR, limits its application to stable samples. Here we demonstrate a method which allows to obtain the spectrum by collecting only a small fraction of the experimental data. Our method is based on matrix completion which can recover the full spectral information from randomly sampled data points. We confirm experimentally the applicability of this technique by performing two dimensional electron spin echo envelope modulation (ESEEM) experiments on a two spin system consisting of a single nitrogen vacancy (NV) centre in diamond coupled to a single 13C nuclear spin. The signal to noise ratio of the recovered 2D spectrum is compared to the Fourier transform of randomly subsampled data, where we observe a strong suppression of the noise when the matrix completion algorithm is applied. We show that the peaks in the spectrum can be obtained with only 10% of the total number of the data points. We believe that our results reported here can find an application in all types of two dimensional spectroscopy, as long as the measured matrices have a low rank.
Identification of Differentially Methylated Sites with Weak Methylation Effects
Tran, Hong; Zhu, Hongxiao; Wu, Xiaowei; Kim, Gunjune; Clarke, Christopher R.; Larose, Hailey; Haak, David C.; Westwood, James H.; Zhang, Liqing
2018-01-01
Deoxyribonucleic acid (DNA) methylation is an epigenetic alteration crucial for regulating stress responses. Identifying large-scale DNA methylation at single nucleotide resolution is made possible by whole genome bisulfite sequencing. An essential task following the generation of bisulfite sequencing data is to detect differentially methylated cytosines (DMCs) among treatments. Most statistical methods for DMC detection do not consider the dependency of methylation patterns across the genome, thus possibly inflating type I error. Furthermore, small sample sizes and weak methylation effects among different phenotype categories make it difficult for these statistical methods to accurately detect DMCs. To address these issues, the wavelet-based functional mixed model (WFMM) was introduced to detect DMCs. To further examine the performance of WFMM in detecting weak differential methylation events, we used both simulated and empirical data and compare WFMM performance to a popular DMC detection tool methylKit. Analyses of simulated data that replicated the effects of the herbicide glyphosate on DNA methylation in Arabidopsis thaliana show that WFMM results in higher sensitivity and specificity in detecting DMCs compared to methylKit, especially when the methylation differences among phenotype groups are small. Moreover, the performance of WFMM is robust with respect to small sample sizes, making it particularly attractive considering the current high costs of bisulfite sequencing. Analysis of empirical Arabidopsis thaliana data under varying glyphosate dosages, and the analysis of monozygotic (MZ) twins who have different pain sensitivities—both datasets have weak methylation effects of <1%—show that WFMM can identify more relevant DMCs related to the phenotype of interest than methylKit. Differentially methylated regions (DMRs) are genomic regions with different DNA methylation status across biological samples. DMRs and DMCs are essentially the same concepts, with the only difference being how methylation information across the genome is summarized. If methylation levels are determined by grouping neighboring cytosine sites, then they are DMRs; if methylation levels are calculated based on single cytosines, they are DMCs. PMID:29419727
Fernández, Elena; Vidal, Lorena; Canals, Antonio
2017-11-23
A new, fast, easy to handle, and environmentally friendly magnetic headspace single-drop microextraction (Mag-HS-SDME) based on a magnetic ionic liquid (MIL) as an extractant solvent is presented. A small drop of the MIL 1-ethyl-3-methylimidazolium tetraisothiocyanatocobaltate(II) ([Emim] 2 [Co(NCS) 4 ]) is located on one end of a small neodymium magnet to extract nine chlorobenzenes (1,2-dichlorobenzene, 1,3-dichlorobenzene, 1,4-dichlorobenzene, 1,2,3-trichlorobenzene, 1,2,4-trichlorobenzene, 1,3,5-trichlorobenzene, 1,2,3,4-tetrachlorobenzene, 1,2,4,5-tetrachlorobenzene, and pentachlorobenzene) as model analytes from water samples prior to thermal desorption-gas chromatography-mass spectrometry determination. A multivariate optimization strategy was employed to optimize experimental parameters affecting Mag-HS-SDME. The method was evaluated under optimized extraction conditions (i.e., sample volume, 20 mL; MIL volume, 1 μL; extraction time, 10 min; stirring speed, 1500 rpm; and ionic strength, 15% NaCl (w/v)), obtaining a linear response from 0.05 to 5 μg L -1 for all analytes. The repeatability of the proposed method was evaluated at 0.7 and 3 μg L -1 spiking levels and coefficients of variation ranged between 3 and 18% (n = 3). Limits of detection were in the order of nanograms per liter ranging from 4 ng L -1 for 1,4-dichlorobenzene and 1,2,3,4-tetrachlorobenzene to 8 ng L -1 for 1,2,4,5-tetrachlorobenzene. Finally, tap water, pond water, and wastewater were selected as real water samples to assess the applicability of the method. Relative recoveries varied between 82 and 114% showing negligible matrix effects. Graphical abstract Magnetic headspace single-drop microextraction followed by thermal desorption-gas chromatography-mass spectrometry.
NASA Astrophysics Data System (ADS)
Deng, Chengbin; Wu, Changshan
2013-12-01
Urban impervious surface information is essential for urban and environmental applications at the regional/national scales. As a popular image processing technique, spectral mixture analysis (SMA) has rarely been applied to coarse-resolution imagery due to the difficulty of deriving endmember spectra using traditional endmember selection methods, particularly within heterogeneous urban environments. To address this problem, we derived endmember signatures through a least squares solution (LSS) technique with known abundances of sample pixels, and integrated these endmember signatures into SMA for mapping large-scale impervious surface fraction. In addition, with the same sample set, we carried out objective comparative analyses among SMA (i.e. fully constrained and unconstrained SMA) and machine learning (i.e. Cubist regression tree and Random Forests) techniques. Analysis of results suggests three major conclusions. First, with the extrapolated endmember spectra from stratified random training samples, the SMA approaches performed relatively well, as indicated by small MAE values. Second, Random Forests yields more reliable results than Cubist regression tree, and its accuracy is improved with increased sample sizes. Finally, comparative analyses suggest a tentative guide for selecting an optimal approach for large-scale fractional imperviousness estimation: unconstrained SMA might be a favorable option with a small number of samples, while Random Forests might be preferred if a large number of samples are available.
Evidence for extreme Ti-50 enrichments in primitive meteorites
NASA Technical Reports Server (NTRS)
Fahey, A.; Mckeegan, K. D.; Zinner, E.; Goswami, J. N.
1985-01-01
The results of the first high mass resolution ion microprobe study of Ti isotopic compositions in individual refractory grains from primitive carbonaceous meteorites are reported. One hibonite from the Murray carbonaceous chondrite has a 10 percent excess of Ti-50, 25 times higher than the maximum value previously reported for bulk samples of refractory inclusions from carbonaceous chondrites. The variation of the Ti compositions between different hibonite grains, and among pyroxenes from a single Allende refractory inclusion, indicates isotopic inhomogeneities over small scale lengths in the solar nebula and emphasizes the importance of the analysis of small individual phases. This heterogeneity makes it unlikely that the isotopic anomalies were carried into the solar system in the gas phase.
Bubble colloidal AFM probes formed from ultrasonically generated bubbles.
Vakarelski, Ivan U; Lee, Judy; Dagastine, Raymond R; Chan, Derek Y C; Stevens, Geoffrey W; Grieser, Franz
2008-02-05
Here we introduce a simple and effective experimental approach to measuring the interaction forces between two small bubbles (approximately 80-140 microm) in aqueous solution during controlled collisions on the scale of micrometers to nanometers. The colloidal probe technique using atomic force microscopy (AFM) was extended to measure interaction forces between a cantilever-attached bubble and surface-attached bubbles of various sizes. By using an ultrasonic source, we generated numerous small bubbles on a mildly hydrophobic surface of a glass slide. A single bubble picked up with a strongly hydrophobized V-shaped cantilever was used as the colloidal probe. Sample force measurements were used to evaluate the pure water bubble cleanliness and the general consistency of the measurements.
Small angle light scattering characterization of single micrometric particles in microfluidic flows
NASA Astrophysics Data System (ADS)
Dannhauser, David; Romeo, Giovanni; Causa, Filippo; Netti, Paolo A.
2013-04-01
A CCD-camera based small angle light scattering (SALS) apparatus has been used to characterize single micrometric particles flowing in a micro-channel. The measured scattering vector spans the range 2x10-2 - 6:8x101μm-1. The incident laser light is collimated to a spot of about 50 μm in diameter at the sample position with a divergence lower than 0.045 rad. Such small collimated laser beam opens the possibility to perform on-line SALS of micron-sized particles flowing in micro-channels. By properly designing the micro-channel and using a viscoelastic liquid as suspending medium we are able to realize a precise 3D focusing of the target particles. The forward scattering emitted from the particle is collected by a lens with high numerical aperture. At the focal point of that lens a homemade beam stop is blocking the incident light. Finally, a second lens maps the scattered light on the CCD sensor, allowing to obtain far field images on short distances. Measurements with mono-disperse polystyrene particles, both in quiescent and in-flow conditions have been realized. Experiments in-flow allow to measure the single particle scattering. Results are validated by comparison with calculations based on the Lorenz-Mie theory. The quality of the measured intensity profiles confirms the possibility to use our apparatus in real multiplex applications, with particles down to 1 μm in radius.
Damage evolution analysis of coal samples under cyclic loading based on single-link cluster method
NASA Astrophysics Data System (ADS)
Zhang, Zhibo; Wang, Enyuan; Li, Nan; Li, Xuelong; Wang, Xiaoran; Li, Zhonghui
2018-05-01
In this paper, the acoustic emission (AE) response of coal samples under cyclic loading is measured. The results show that there is good positive relation between AE parameters and stress. The AE signal of coal samples under cyclic loading exhibits an obvious Kaiser Effect. The single-link cluster (SLC) method is applied to analyze the spatial evolution characteristics of AE events and the damage evolution process of coal samples. It is found that a subset scale of the SLC structure becomes smaller and smaller when the number of cyclic loading increases, and there is a negative linear relationship between the subset scale and the degree of damage. The spatial correlation length ξ of an SLC structure is calculated. The results show that ξ fluctuates around a certain value from the second cyclic loading process to the fifth cyclic loading process, but spatial correlation length ξ clearly increases in the sixth loading process. Based on the criterion of microcrack density, the coal sample failure process is the transformation from small-scale damage to large-scale damage, which is the reason for changes in the spatial correlation length. Through a systematic analysis, the SLC method is an effective method to research the damage evolution process of coal samples under cyclic loading, and will provide important reference values for studying coal bursts.
NASA Astrophysics Data System (ADS)
Dirilgen, Tara; Juceviča, Edite; Melecis, Viesturs; Querner, Pascal; Bolger, Thomas
2018-01-01
The relative importance of niche separation, non-equilibrial and neutral models of community assembly has been a theme in community ecology for many decades with none appearing to be applicable under all circumstances. In this study, Collembola species abundances were recorded over eleven consecutive years in a spatially explicit grid and used to examine (i) whether observed beta diversity differed from that expected under conditions of neutrality, (ii) whether sampling points differed in their relative contributions to overall beta diversity, and (iii) the number of samples required to provide comparable estimates of species richness across three forest sites. Neutrality could not be rejected for 26 of the forest by year combinations. However, there is a trend toward greater structure in the oldest forest, where beta diversity was greater than predicted by neutrality on five of the eleven sampling dates. The lack of difference in individual- and sample-based rarefaction curves also suggests randomness in the system at this particular scale of investigation. It seems that Collembola communities are not spatially aggregated and assembly is driven primarily by neutral processes particularly in the younger two sites. Whether this finding is due to small sample size or unaccounted for environmental variables cannot be determined. Variability between dates and sites illustrates the potential of drawing incorrect conclusions if data are collected at a single site and a single point in time.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rivkin, R.B.; Seliger, H.H.
1981-07-01
Short term rates of /sup 14/C uptake for single cells and small numbers of isolated algal cells of five phytoplankton species from natural populations were measured by liquid scintillation counting. Regression analysis of uptake rates per cell for cells isolated from unialgal cultures of seven species of dinoflagellates, ranging in volume from ca. 10/sup 3/ to 10/sup 7/ ..mu..m/sup 3/, gave results identical to uptake rates per cell measured by conventional /sup 14/C techniques. Relative standard errors or regression coefficients ranged between 3 and 10%, indicating that for any species there was little variation in photosynthesis per cell.
A Sub-Sampling Approach for Data Acquisition in Gamma Ray Emission Tomography
NASA Astrophysics Data System (ADS)
Fysikopoulos, Eleftherios; Kopsinis, Yannis; Georgiou, Maria; Loudos, George
2016-06-01
State of the art data acquisition systems for small animal imaging gamma ray detectors often rely on free running Analog to Digital Converters (ADCs) and high density Field Programmable Gate Arrays (FPGA) devices for digital signal processing. In this work, a sub-sampling acquisition approach, which exploits a priori information regarding the shape of the obtained detector pulses is proposed. Output pulses shape depends on the response of the scintillation crystal, photodetector's properties and amplifier/shaper operation. Using these known characteristics of the detector pulses prior to digitization, one can model the voltage pulse derived from the shaper (a low-pass filter, last in the front-end electronics chain), in order to reduce the desirable sampling rate of ADCs. Fitting with a small number of measurements, pulse shape estimation is then feasible. In particular, the proposed sub-sampling acquisition approach relies on a bi-exponential modeling of the pulse shape. We show that the properties of the pulse that are relevant for Single Photon Emission Computed Tomography (SPECT) event detection (i.e., position and energy) can be calculated by collecting just a small fraction of the number of samples usually collected in data acquisition systems used so far. Compared to the standard digitization process, the proposed sub-sampling approach allows the use of free running ADCs with sampling rate reduced by a factor of 5. Two small detectors consisting of Cerium doped Gadolinium Aluminum Gallium Garnet (Gd3Al2Ga3O12 : Ce or GAGG:Ce) pixelated arrays (array elements: 2 × 2 × 5 mm3 and 1 × 1 × 10 mm3 respectively) coupled to a Position Sensitive Photomultiplier Tube (PSPMT) were used for experimental evaluation. The two detectors were used to obtain raw images and energy histograms under 140 keV and 661.7 keV irradiation respectively. The sub-sampling acquisition technique (10 MHz sampling rate) was compared with a standard acquisition method (52 MHz sampling rate), in terms of energy resolution and image signal to noise ratio for both gamma ray energies. The Levenberg-Marquardt (LM) non-linear least-squares algorithm was used, in post processing, in order to fit the acquired data with the proposed model. The results showed that analog pulses prior to digitization are being estimated with high accuracy after fitting with the bi-exponential model.
Drone Transport of Chemistry and Hematology Samples Over Long Distances.
Amukele, Timothy K; Hernandez, James; Snozek, Christine L H; Wyatt, Ryan G; Douglas, Matthew; Amini, Richard; Street, Jeff
2017-11-02
We addressed the stability of biological samples in prolonged drone flights by obtaining paired chemistry and hematology samples from 21 adult volunteers in a single phlebotomy event-84 samples total. Half of the samples were held stationary, while the other samples were flown for 3 hours (258 km) in a custom active cooling box mounted on the drone. After the flight, 19 chemistry and hematology tests were performed. Seventeen analytes had small or no bias, but glucose and potassium in flown samples showed an 8% and 6.2% bias, respectively. The flown samples (mean, 24.8°C) were a mean of 2.5°C cooler than the stationary samples (mean, 27.3°C) during transportation to the flight field as well as during the flight. The changes in glucose and potassium are consistent with the magnitude and duration of the temperature difference between the flown and stationary samples. Long drone flights of biological samples are feasible but require stringent environmental controls to ensure consistent results. © American Society for Clinical Pathology, 2017. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com
Handling limited datasets with neural networks in medical applications: A small-data approach.
Shaikhina, Torgyn; Khovanova, Natalia A
2017-01-01
Single-centre studies in medical domain are often characterised by limited samples due to the complexity and high costs of patient data collection. Machine learning methods for regression modelling of small datasets (less than 10 observations per predictor variable) remain scarce. Our work bridges this gap by developing a novel framework for application of artificial neural networks (NNs) for regression tasks involving small medical datasets. In order to address the sporadic fluctuations and validation issues that appear in regression NNs trained on small datasets, the method of multiple runs and surrogate data analysis were proposed in this work. The approach was compared to the state-of-the-art ensemble NNs; the effect of dataset size on NN performance was also investigated. The proposed framework was applied for the prediction of compressive strength (CS) of femoral trabecular bone in patients suffering from severe osteoarthritis. The NN model was able to estimate the CS of osteoarthritic trabecular bone from its structural and biological properties with a standard error of 0.85MPa. When evaluated on independent test samples, the NN achieved accuracy of 98.3%, outperforming an ensemble NN model by 11%. We reproduce this result on CS data of another porous solid (concrete) and demonstrate that the proposed framework allows for an NN modelled with as few as 56 samples to generalise on 300 independent test samples with 86.5% accuracy, which is comparable to the performance of an NN developed with 18 times larger dataset (1030 samples). The significance of this work is two-fold: the practical application allows for non-destructive prediction of bone fracture risk, while the novel methodology extends beyond the task considered in this study and provides a general framework for application of regression NNs to medical problems characterised by limited dataset sizes. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Amigó, M. L.; Haberkorn, N.; Pérez, P.; Suárez, S.; Nieva, G.
2017-12-01
We report on the critical current density J c and the vortex dynamics of pristine and 3 MeV proton irradiated (cumulative dose equal to 2× {10}16 cm-2) β-FeSe single crystals. We also analyze a remarkable dependence of the superconducting critical temperature T c, J c and the flux creep rate S on the sample mounting method. Free-standing crystals present T c = 8.4(1) K, which increases to 10.5(1) K when they are fixed to the sample holder by embedding them with GE-7031 varnish. On the other hand, the irradiation has a marginal effect on T c. The pinning scenario can be ascribed to twin boundaries and random point defects. We find that the main effect of irradiation is to increase the density of random point defects, while the embedding mainly reduces the density of twin boundaries. Pristine and irradiated crystals present two outstanding features in the temperature dependence of the flux creep rate: S(T) presents large values at low temperatures, which can be attributed to small pinning energies, and a plateau at intermediate temperatures, which can be associated with glassy relaxation. From Maley analysis, we observe that the characteristic glassy exponent μ changes from ˜1.7 to 1.35-1.4 after proton irradiation.
Neeser, Rudolph; Ackermann, Rebecca Rogers; Gain, James
2009-09-01
Various methodological approaches have been used for reconstructing fossil hominin remains in order to increase sample sizes and to better understand morphological variation. Among these, morphometric quantitative techniques for reconstruction are increasingly common. Here we compare the accuracy of three approaches--mean substitution, thin plate splines, and multiple linear regression--for estimating missing landmarks of damaged fossil specimens. Comparisons are made varying the number of missing landmarks, sample sizes, and the reference species of the population used to perform the estimation. The testing is performed on landmark data from individuals of Homo sapiens, Pan troglodytes and Gorilla gorilla, and nine hominin fossil specimens. Results suggest that when a small, same-species fossil reference sample is available to guide reconstructions, thin plate spline approaches perform best. However, if no such sample is available (or if the species of the damaged individual is uncertain), estimates of missing morphology based on a single individual (or even a small sample) of close taxonomic affinity are less accurate than those based on a large sample of individuals drawn from more distantly related extant populations using a technique (such as a regression method) able to leverage the information (e.g., variation/covariation patterning) contained in this large sample. Thin plate splines also show an unexpectedly large amount of error in estimating landmarks, especially over large areas. Recommendations are made for estimating missing landmarks under various scenarios. Copyright 2009 Wiley-Liss, Inc.
Rissmann, M; Eiden, M; El Mamy, B O; Isselmou, K; Doumbia, B; Ziegler, U; Homeier-Bachmann, T; Yahya, B; Groschup, M H
2017-04-01
Rift Valley fever virus (RVFV) is an emerging pathogen of major concern throughout Africa and the Arabian Peninsula, affecting both livestock and humans. In the past recurrent epidemics were reported in Mauritania and studies focused on the analysis of samples from affected populations during acute outbreaks. To verify characteristics and presence of RVFV during non-epidemic periods we implemented a multi-stage serological and molecular analysis. Serum samples of small ruminants, cattle and camels were obtained from Mauritania during an inter-epidemic period in 2012-2013. This paper presents a comparative analysis of potential variations and shifts of antibody presence and the capability of inter-epidemic infections in Mauritanian livestock. We observed distinct serological differences between tested species (seroprevalence: small ruminants 3·8%, cattle 15·4%, camels 32·0%). In one single bovine from Nouakchott, a recent RVF infection could be identified by the simultaneous detection of IgM antibodies and viral RNA. This study indicates the occurrence of a low-level enzootic RVFV circulation in livestock in Mauritania. Moreover, results indicate that small ruminants can preferably act as sentinels for RVF surveillance.
Single cell transcriptomic analysis of prostate cancer cells.
Welty, Christopher J; Coleman, Ilsa; Coleman, Roger; Lakely, Bryce; Xia, Jing; Chen, Shu; Gulati, Roman; Larson, Sandy R; Lange, Paul H; Montgomery, Bruce; Nelson, Peter S; Vessella, Robert L; Morrissey, Colm
2013-02-16
The ability to interrogate circulating tumor cells (CTC) and disseminated tumor cells (DTC) is restricted by the small number detected and isolated (typically <10). To determine if a commercially available technology could provide a transcriptomic profile of a single prostate cancer (PCa) cell, we clonally selected and cultured a single passage of cell cycle synchronized C4-2B PCa cells. Ten sets of single, 5-, or 10-cells were isolated using a micromanipulator under direct visualization with an inverted microscope. Additionally, two groups of 10 individual DTC, each isolated from bone marrow of 2 patients with metastatic PCa were obtained. RNA was amplified using the WT-Ovation™ One-Direct Amplification System. The amplified material was hybridized on a 44K Whole Human Gene Expression Microarray. A high stringency threshold, a mean Alexa Fluor® 3 signal intensity above 300, was used for gene detection. Relative expression levels were validated for select genes using real-time PCR (RT-qPCR). Using this approach, 22,410, 20,423, and 17,009 probes were positive on the arrays from 10-cell pools, 5-cell pools, and single-cells, respectively. The sensitivity and specificity of gene detection on the single-cell analyses were 0.739 and 0.972 respectively when compared to 10-cell pools, and 0.814 and 0.979 respectively when compared to 5-cell pools, demonstrating a low false positive rate. Among 10,000 randomly selected pairs of genes, the Pearson correlation coefficient was 0.875 between the single-cell and 5-cell pools and 0.783 between the single-cell and 10-cell pools. As expected, abundant transcripts in the 5- and 10-cell samples were detected by RT-qPCR in the single-cell isolates, while lower abundance messages were not. Using the same stringency, 16,039 probes were positive on the patient single-cell arrays. Cluster analysis showed that all 10 DTC grouped together within each patient. A transcriptomic profile can be reliably obtained from a single cell using commercially available technology. As expected, fewer amplified genes are detected from a single-cell sample than from pooled-cell samples, however this method can be used to reliably obtain a transcriptomic profile from DTC isolated from the bone marrow of patients with PCa.
Nonuniformity of diffusing capacity from small alveolar gas samples is increased in smokers.
Cotton, D J; Mink, J T; Graham, B L
1998-01-01
Although centrilobular emphysema, and small airway, interstitial and alveoli inflammation can be detected pathologically in the lungs of smokers with relatively well preserved lung function, these changes are difficult to assess using available physiological tests. Because submaximal single breath washout (SBWSM) manoeuvres improve the detection of abnormalities in ventilation inhomogeneity in the lung periphery in smokers compared with traditional vital capacity manoeuvres, SBWSM manoeuvres were used in this study to measure temporal differences in diffusing capacity using a rapid response carbon monoxide analyzer. To determine whether abnormalities in the lung periphery can be detected in smokers with normal forced expired volumes in 1 s using the three-equation diffusing capacity (DLcoSB-3EQ) among small alveolar gas samples and whether the abnormalities correlate with increases in peripheral ventilation inhomogeneity. Cross-sectional study in 21 smokers and 21 nonsmokers all with normal forced exhaled flow rates. Both smokers and nonsmokers performed SBWSM manoeuvres consisting of slow inhalation of test gas from functional residual capacity to one-half inspiratory capacity with either 0 or 10 s of breath holding and slow exhalation to residual volume (RV). They also performed conventional vital capacity single breath (SBWVC) manoeuvres consisting of slow inhalation of test gas from RV to total lung capacity and, without breath holding, slow exhalation to RV. DLcoSB-3EQ was calculated from the total alveolar gas sample. DLcoSB-3EQ was also calculated from four equal sequential, simulated aliquots of the total alveolar gas sample. DLcoSB-3EQ values from the four alveolar samples were normalized by expressing each as a percentge of DLcoSB-3EQ from the entire alveolar gas sample. An index of variation (DI) among the small-sample DLcoSB-3EQ values was correlated with the normalized phase III helium slope (Sn) and the mixing efficiency (Emix). For SBWSM, DI was increased in smokers at 0 s of breath holding compared with nonsmokers, and correlated with age, smoking pack-years and Sn. The decrease in DI with breath holding was greater in smokers and correlated with the change in Sn with breath holding. For SBWVC manoeuvres, there were no differences due to smoking in Sn or Emix, but DI was increased in smokers and correlated with age and smoking pack-years, but not with Sn. For SBWSM manoeuvres the increase in DI in smokers correlated with breath hold time-dependent increases in Sn, suggesting that the changes in DI reflected the same structural alterations that caused increases in peripheral ventilation inhomogeneity. For SBWVC manoeuvres, the increase in DI in smokers was not associated with changes in ventilation inhomogeneity, suggesting that the effect of smoking on DI during this manoeuvre was due to smoke-related changes in alveolar capillary diffusion, rather than due solely to alterations in the distribution of ventilation.
The IGF1 small dog haplotype is derived from Middle Eastern grey wolves.
Gray, Melissa M; Sutter, Nathan B; Ostrander, Elaine A; Wayne, Robert K
2010-02-24
A selective sweep containing the insulin-like growth factor 1 (IGF1) gene is associated with size variation in domestic dogs. Intron 2 of IGF1 contains a SINE element and single nucleotide polymorphism (SNP) found in all small dog breeds that is almost entirely absent from large breeds. In this study, we surveyed a large sample of grey wolf populations to better understand the ancestral pattern of variation at IGF1 with a particular focus on the distribution of the small dog haplotype and its relationship to the origin of the dog. We present DNA sequence data that confirms the absence of the derived small SNP allele in the intron 2 region of IGF1 in a large sample of grey wolves and further establishes the absence of a small dog associated SINE element in all wild canids and most large dog breeds. Grey wolf haplotypes from the Middle East have higher nucleotide diversity suggesting an origin there. Additionally, PCA and phylogenetic analyses suggests a closer kinship of the small domestic dog IGF1 haplotype with those from Middle Eastern grey wolves. The absence of both the SINE element and SNP allele in grey wolves suggests that the mutation for small body size post-dates the domestication of dogs. However, because all small dogs possess these diagnostic mutations, the mutations likely arose early in the history of domestic dogs. Our results show that the small dog haplotype is closely related to those in Middle Eastern wolves and is consistent with an ancient origin of the small dog haplotype there. Thus, in concordance with past archeological studies, our molecular analysis is consistent with the early evolution of small size in dogs from the Middle East.See associated opinion by Driscoll and Macdonald: http://jbiol.com/content/9/2/10.
Characterization of circulating tumor cell aggregates identified in patients with epithelial tumors
NASA Astrophysics Data System (ADS)
Cho, Edward H.; Wendel, Marco; Luttgen, Madelyn; Yoshioka, Craig; Marrinucci, Dena; Lazar, Daniel; Schram, Ethan; Nieva, Jorge; Bazhenova, Lyudmila; Morgan, Alison; Ko, Andrew H.; Korn, W. Michael; Kolatkar, Anand; Bethel, Kelly; Kuhn, Peter
2012-02-01
Circulating tumor cells (CTCs) have been implicated as a population of cells that may seed metastasis and venous thromboembolism (VTE), two major causes of mortality in cancer patients. Thus far, existing CTC detection technologies have been unable to reproducibly detect CTC aggregates in order to address what contribution CTC aggregates may make to metastasis or VTE. We report here an enrichment-free immunofluorescence detection method that can reproducibly detect and enumerate homotypic CTC aggregates in patient samples. We identified CTC aggregates in 43% of 86 patient samples. The fraction of CTC aggregation was investigated in blood draws from 24 breast, 14 non-small cell lung, 18 pancreatic, 15 prostate stage IV cancer patients and 15 normal blood donors. Both single CTCs and CTC aggregates were measured to determine whether differences exist in the physical characteristics of these two populations. Cells contained in CTC aggregates had less area and length, on average, than single CTCs. Nuclear to cytoplasmic ratios between single CTCs and CTC aggregates were similar. This detection method may assist future studies in determining which population of cells is more physically likely to contribute to metastasis and VTE.
Assessment of In Situ Time Resolved Shock Experiments at Synchrotron Light Sources*
NASA Astrophysics Data System (ADS)
Belak, J.; Ilavsky, J.; Hessler, J. P.
2005-07-01
Prior to fielding in situ time resolved experiments of shock wave loading at the Advanced Photon Source, we have performed feasibility experiments assessing a single photon bunch. Using single and poly-crystal Al, Ti, V and Cu shock to incipient spallation on the gas gun, samples were prepared from slices normal to the spall plane of thickness 100-500 microns. In addition, single crystal Al of thickness 500 microns was shocked to incipient spallation and soft recovered using the LLNL e-gun mini-flyer system. The e-gun mini-flyer impacts the sample target producing a 10's ns flat-top shock transient. Here, we present results for imaging, small-angle scattering (SAS), and diffraction. In particular, there is little SAS away from the spall plane and significant SAS at the spall plane, demonstrating the presence of sub-micron voids. * Use of the Advanced Photon Source was supported by the U. S. Department of Energy, Office of Science, Office of Basic Energy Sciences, under Contract No. W-31-109-Eng-38 and work performed under the auspices of the U.S. Department of Energy by University of California, Lawrence Livermore National Laboratory under Contract W-7405-Eng-48.
Marcus, Hani J.; Seneci, Carlo A.; Hughes-Hallett, Archie; Cundy, Thomas P.; Nandi, Dipankar; Yang, Guang-Zhong; Darzi, Ara
2015-01-01
Background. Surgical approaches such as transanal endoscopic microsurgery, which utilize small operative working spaces, and are necessarily single-port, are particularly demanding with standard instruments and have not been widely adopted. The aim of this study was to compare simultaneously surgical performance in single-port versus multiport approaches, and small versus large working spaces. Methods. Ten novice, 4 intermediate, and 1 expert surgeons were recruited from a university hospital. A preclinical randomized crossover study design was implemented, comparing performance under the following conditions: (1) multiport approach and large working space, (2) multiport approach and intermediate working space, (3) single-port approach and large working space, (4) single-port approach and intermediate working space, and (5) single-port approach and small working space. In each case, participants performed a peg transfer and pattern cutting tasks, and each task repetition was scored. Results. Intermediate and expert surgeons performed significantly better than novices in all conditions (P < .05). Performance in single-port surgery was significantly worse than multiport surgery (P < .01). In multiport surgery, there was a nonsignificant trend toward worsened performance in the intermediate versus large working space. In single-port surgery, there was a converse trend; performances in the intermediate and small working spaces were significantly better than in the large working space. Conclusions. Single-port approaches were significantly more technically challenging than multiport approaches, possibly reflecting loss of instrument triangulation. Surprisingly, in single-port approaches, in which triangulation was no longer a factor, performance in large working spaces was worse than in intermediate and small working spaces. PMID:26464468
Small Gas Turbine Combustor Primary Zone Study
NASA Technical Reports Server (NTRS)
Sullivan, R. E.; Young, E. R.; Miles, G. A.; Williams, J. R.
1983-01-01
A development process is described which consists of design, fabrication, and preliminary test evaluations of three approaches to internal aerodynamic primary zone flow patterns: (1) conventional double vortex swirl stabilization; (2) reverse flow swirl stabilization; and (3) large single vortex flow system. Each concept incorporates special design features aimed at extending the performance capability of the small engine combustor. Since inherent geometry of these combustors result in small combustion zone height and high surface area to volume ratio, design features focus on internal aerodynamics, fuel placement, and advanced cooling. The combustors are evaluated on a full scale annular combustor rig. A correlation of the primary zone performance with the overall performance is accomplished using three intrusion type gas sampling probes located at the exit of the primary zone section. Empirical and numerical methods are used for designing and predicting the performance of the three combustor concepts and their subsequent modifications. The calibration of analytical procedures with actual test results permits an updating of the analytical design techniques applicable to small reverse flow annular combustors.
Integrative Analysis of Cancer Diagnosis Studies with Composite Penalization
Liu, Jin; Huang, Jian; Ma, Shuangge
2013-01-01
Summary In cancer diagnosis studies, high-throughput gene profiling has been extensively conducted, searching for genes whose expressions may serve as markers. Data generated from such studies have the “large d, small n” feature, with the number of genes profiled much larger than the sample size. Penalization has been extensively adopted for simultaneous estimation and marker selection. Because of small sample sizes, markers identified from the analysis of single datasets can be unsatisfactory. A cost-effective remedy is to conduct integrative analysis of multiple heterogeneous datasets. In this article, we investigate composite penalization methods for estimation and marker selection in integrative analysis. The proposed methods use the minimax concave penalty (MCP) as the outer penalty. Under the homogeneity model, the ridge penalty is adopted as the inner penalty. Under the heterogeneity model, the Lasso penalty and MCP are adopted as the inner penalty. Effective computational algorithms based on coordinate descent are developed. Numerical studies, including simulation and analysis of practical cancer datasets, show satisfactory performance of the proposed methods. PMID:24578589
Late-Onset Alzheimer's Disease Polygenic Risk Profile Score Predicts Hippocampal Function.
Xiao, Ena; Chen, Qiang; Goldman, Aaron L; Tan, Hao Yang; Healy, Kaitlin; Zoltick, Brad; Das, Saumitra; Kolachana, Bhaskar; Callicott, Joseph H; Dickinson, Dwight; Berman, Karen F; Weinberger, Daniel R; Mattay, Venkata S
2017-11-01
We explored the cumulative effect of several late-onset Alzheimer's disease (LOAD) risk loci using a polygenic risk profile score (RPS) approach on measures of hippocampal function, cognition, and brain morphometry. In a sample of 231 healthy control subjects (19-55 years of age), we used an RPS to study the effect of several LOAD risk loci reported in a recent meta-analysis on hippocampal function (determined by its engagement with blood oxygen level-dependent functional magnetic resonance imaging during episodic memory) and several cognitive metrics. We also studied effects on brain morphometry in an overlapping sample of 280 subjects. There was almost no significant association of LOAD-RPS with cognitive or morphometric measures. However, there was a significant negative relationship between LOAD-RPS and hippocampal function (familywise error [small volume correction-hippocampal region of interest] p < .05). There were also similar associations for risk score based on APOE haplotype, and for a combined LOAD-RPS + APOE haplotype risk profile score (p < .05 familywise error [small volume correction-hippocampal region of interest]). Of the 29 individual single nucleotide polymorphisms used in calculating LOAD-RPS, variants in CLU, PICALM, BCL3, PVRL2, and RELB showed strong effects (p < .05 familywise error [small volume correction-hippocampal region of interest]) on hippocampal function, though none survived further correction for the number of single nucleotide polymorphisms tested. There is a cumulative deleterious effect of LOAD risk genes on hippocampal function even in healthy volunteers. The effect of LOAD-RPS on hippocampal function in the relative absence of any effect on cognitive and morphometric measures is consistent with the reported temporal characteristics of LOAD biomarkers with the earlier manifestation of synaptic dysfunction before morphometric and cognitive changes. Copyright © 2017 Society of Biological Psychiatry. All rights reserved.
Response Variability in Commercial MOSFET SEE Qualification
George, J. S.; Clymer, D. A.; Turflinger, T. L.; ...
2016-12-01
Single-event effects (SEE) evaluation of five different part types of next generation, commercial trench MOSFETs indicates large part-to-part variation in determining a safe operating area (SOA) for drain-source voltage (V DS) following a test campaign that exposed >50 samples per part type to heavy ions. These results suggest a determination of a SOA using small sample sizes may fail to capture the full extent of the part-to-part variability. An example method is discussed for establishing a Safe Operating Area using a one-sided statistical tolerance limit based on the number of test samples. Finally, burn-in is shown to be a criticalmore » factor in reducing part-to-part variation in part response. Implications for radiation qualification requirements are also explored.« less
Petrology and geochemistry of lithic fragments separated from the Apollo 15 deep-drill core
NASA Technical Reports Server (NTRS)
Lindstrom, M. M.; Nielsen, R. L.; Drake, M. J.
1977-01-01
Petrological and geochemical analysis of lithic fragments separated from the Apollo 15 deep-drill core showed these fragments to fall into the essentially the same range of rock types as observed in surface soil samples and large rock samples. Three particles are singled out as being of special interest. One sample is a mare basalt containing extremely evolved phases. The particle may represent small-scale imperfect crystal/liquid separation in a lava flow. A green glass particle is not the ultramafic emerald green glass described from the Apollo 15 site, but rather an ANT-like light green color, and has a quite different chemical composition from the ultramafic variety. One mare basalt displays a positive Eu anomaly and is enriched in plagioclase relative to olivine plus pyroxene.
Response Variability in Commercial MOSFET SEE Qualification
DOE Office of Scientific and Technical Information (OSTI.GOV)
George, J. S.; Clymer, D. A.; Turflinger, T. L.
Single-event effects (SEE) evaluation of five different part types of next generation, commercial trench MOSFETs indicates large part-to-part variation in determining a safe operating area (SOA) for drain-source voltage (V DS) following a test campaign that exposed >50 samples per part type to heavy ions. These results suggest a determination of a SOA using small sample sizes may fail to capture the full extent of the part-to-part variability. An example method is discussed for establishing a Safe Operating Area using a one-sided statistical tolerance limit based on the number of test samples. Finally, burn-in is shown to be a criticalmore » factor in reducing part-to-part variation in part response. Implications for radiation qualification requirements are also explored.« less
Apparatus to collect, classify, concentrate, and characterize gas-borne particles
Rader, Daniel J.; Torczynski, John R.; Wally, Karl; Brockmann, John E.
2002-01-01
An aerosol lab-on-a-chip (ALOC) integrates one or more of a variety of aerosol collection, classification, concentration (enrichment), and characterization processes onto a single substrate or layered stack of such substrates. By taking advantage of modern micro-machining capabilities, an entire suite of discrete laboratory aerosol handling and characterization techniques can be combined in a single portable device that can provide a wealth of data on the aerosol being sampled. The ALOC offers parallel characterization techniques and close proximity of the various characterization modules helps ensure that the same aerosol is available to all devices (dramatically reducing sampling and transport errors). Micro-machine fabrication of the ALOC significantly reduces unit costs relative to existing technology, and enables the fabrication of small, portable ALOC devices, as well as the potential for rugged design to allow operation in harsh environments. Miniaturization also offers the potential of working with smaller particle sizes and lower pressure drops (leading to reduction of power consumption).
Developing noninvasive diagnosis for single-gene disorders: the role of digital PCR.
Barrett, Angela N; Chitty, Lyn S
2014-01-01
Cell-free fetal DNA constitutes approximately 10 % of the cell-free DNA found in maternal plasma and can be used as a reliable source of fetal genetic material for noninvasive prenatal diagnosis (NIPD) from early pregnancy. The relatively high levels of maternal background can make detection of paternally inherited point mutations challenging. Diagnosis of inheritance of autosomal recessive disorders using qPCR is even more challenging due to the high background of mutant maternal allele. Digital PCR is a very sensitive modified method of quantitative real-time PCR (qPCR), allowing absolute quantitation and rare allele detection without the need for standards or normalization. Samples are diluted and then partitioned into a large number of small qPCR reactions, some of which contain the target molecule and some which do not; the proportion of positive reactions can be used to calculate the concentration of targets in the initial sample. Here we discuss the use of digital PCR as an accurate approach to NIPD for single-gene disorders.
Samur, Dalya; Tops, Mattie; Koole, Sander L
2018-02-01
Prior experiments indicated that reading literary fiction improves mentalising performance relative to reading popular fiction, non-fiction, or not reading. However, the experiments had relatively small sample sizes and hence low statistical power. To address this limitation, the present authors conducted four high-powered replication experiments (combined N = 1006) testing the causal impact of reading literary fiction on mentalising. Relative to the original research, the present experiments used the same literary texts in the reading manipulation; the same mentalising task; and the same kind of participant samples. Moreover, one experiment was pre-registered as a direct replication. In none of the experiments did reading literary fiction have any effect on mentalising relative to control conditions. The results replicate earlier findings that familiarity with fiction is positively correlated with mentalising. Taken together, the present findings call into question whether a single session of reading fiction leads to immediate improvements in mentalising.
Deformation-Induced Recrystallization of Magnesium Single Crystals at Ambient Temperature
NASA Astrophysics Data System (ADS)
Molodov, K. D.; Al-Samman, T.; Molodov, D. A.
2015-04-01
Specially oriented magnesium single crystals were subjected to plane strain compression along the <112¯0> direction in c-axis extension at ambient temperature. The samples exhibited outstanding formability deforming up to a logarithmic final strain of -1. Investigations by optical and orientation imaging microscopy revealed that massive {101¯2} extension twinning at low strains consumed the whole sample and resulted in new soft orientations for slip. Observations also indicated that additional twinning took place in the completely twinned matrix by secondary and tertiary twinning events. At advanced stages of deformation newly formed, equiaxed small grains were observed within numerous bands related to former deformation twins. These “recrystallized” grains characterized by a low grain orientation spread of less than 1° generated new orientations, which led to a substantial weakening and randomization of the texture during deformation up to very large strains. The reported results in this paper are discussed with regard to the microstructure evolution arising from multiple twinning and continuous dynamic recrystallization at room temperature.
Quantitative analysis of H2O and CO2 in cordierite using polarized FTIR spectroscopy
NASA Astrophysics Data System (ADS)
Della Ventura, Giancarlo; Radica, Francesco; Bellatreccia, Fabio; Cavallo, Andrea; Capitelli, Francesco; Harley, Simon
2012-11-01
We report a FTIR (Fourier transform infrared) study of a set of cordierite samples from different occurrence and with different H2O/CO2 content. The specimens were fully characterized by a combination of techniques including optical microscopy, single-crystal X-ray diffraction, EMPA (electron microprobe analysis), SIMS (secondary ion mass spectrometry), and FTIR spectroscopy. All cordierites are orthorhombic Ccmm. According to the EMPA data, the Si/Al ratio is always close to 5:4; X Mg ranges from 76.31 to 96.63, and additional octahedral constituents occur in very small amounts. Extraframework K and Ca are negligible, while Na reaches the values up to 0.84 apfu. SIMS shows H2O up to 1.52 and CO2 up to 1.11 wt%. Optically transparent single crystals were oriented using the spindle stage and examined by FTIR micro-spectroscopy under polarized light. On the basis of the polarizing behaviour, the observed bands were assigned to water molecules in two different orientations and to CO2 molecules in the structural channels. The IR spectra also show the presence of small amounts of CO in the samples. Refined integrated molar absorption coefficients were calibrated for the quantitative microanalysis of both H2O and CO2 in cordierite based on single-crystal polarized-light FTIR spectroscopy. For H2O the integrated molar coefficients for type I and type II water molecules (ν3 modes) were calculated separately and are [I]ɛ = 5,200 ± 700 l mol-1 cm-2 and [II]ɛ = 13,000 ± 3,000 l mol-1 cm-2, respectively. For CO2 the integrated coefficient is \\varepsilon_{{{{CO}}_{ 2} }} = 19,000 ± 2,000 l mol-1 cm-2.
NASA Astrophysics Data System (ADS)
Lagus, Todd P.; Edd, Jon F.
2013-03-01
Most cell biology experiments are performed in bulk cell suspensions where cell secretions become diluted and mixed in a contiguous sample. Confinement of single cells to small, picoliter-sized droplets within a continuous phase of oil provides chemical isolation of each cell, creating individual microreactors where rare cell qualities are highlighted and otherwise undetectable signals can be concentrated to measurable levels. Recent work in microfluidics has yielded methods for the encapsulation of cells in aqueous droplets and hydrogels at kilohertz rates, creating the potential for millions of parallel single-cell experiments. However, commercial applications of high-throughput microdroplet generation and downstream sensing and actuation methods are still emerging for cells. Using fluorescence-activated cell sorting (FACS) as a benchmark for commercially available high-throughput screening, this focused review discusses the fluid physics of droplet formation, methods for cell encapsulation in liquids and hydrogels, sensors and actuators and notable biological applications of high-throughput single-cell droplet microfluidics.
Maggin, Daniel M; Swaminathan, Hariharan; Rogers, Helen J; O'Keeffe, Breda V; Sugai, George; Horner, Robert H
2011-06-01
A new method for deriving effect sizes from single-case designs is proposed. The strategy is applicable to small-sample time-series data with autoregressive errors. The method uses Generalized Least Squares (GLS) to model the autocorrelation of the data and estimate regression parameters to produce an effect size that represents the magnitude of treatment effect from baseline to treatment phases in standard deviation units. In this paper, the method is applied to two published examples using common single case designs (i.e., withdrawal and multiple-baseline). The results from these studies are described, and the method is compared to ten desirable criteria for single-case effect sizes. Based on the results of this application, we conclude with observations about the use of GLS as a support to visual analysis, provide recommendations for future research, and describe implications for practice. Copyright © 2011 Society for the Study of School Psychology. Published by Elsevier Ltd. All rights reserved.
Saber, Ali; Hiltermann, T Jeroen N; Kok, Klaas; Terpstra, M Martijn; de Lange, Kim; Timens, Wim; Groen, Harry J M; van den Berg, Anke
2017-02-01
Several studies have shown heterogeneity in lung cancer, with parallel existence of multiple subclones characterized by their own specific mutational landscape. The extent to which minor clones become dominant in distinct metastasis is not clear. The aim of our study was to gain insight in the evolution pattern of lung cancer by investigating genomic heterogeneity between primary tumor and its distant metastases. Whole exome sequencing (WES) was performed on 24 tumor and five normal samples of two small cell lung carcinoma (SCLC) and three non-SCLC (NSCLC) patients. Validation of somatic variants in these 24 and screening of 33 additional samples was done by single primer enrichment technology. For each of the three NSCLC patients, about half of the mutations were shared between all tumor samples, whereas for SCLC patients, this percentage was around 95. Independent validation of the non-ubiquitous mutations confirmed the WES data for the vast majority of the variants. Phylogenetic trees indicated more distance between the tumor samples of the NSCLC patients as compared to the SCLC patients. Analysis of 30 independent DNA samples of 16 biopsies used for WES revealed a low degree of intra-tumor heterogeneity of the selected sets of mutations. In the primary tumors of all five patients, variable percentages (19-67%) of the seemingly metastases-specific mutations were present albeit at low read frequencies. Patients with advanced NSCLC have a high percentage of non-ubiquitous mutations indicative of branched evolution. In contrast, the low degree of heterogeneity in SCLC suggests a parallel and linear model of evolution. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
A Small Diameter Rosette for Sampling Ice Covered Waters
NASA Astrophysics Data System (ADS)
Chayes, D. N.; Smethie, W. M.; Perry, R. S.; Schlosser, P.; Friedrich, R.
2011-12-01
A gas tight, small diameter, lightweight rosette, supporting equipment and an effective operational protocol has been developed for aircraft supported sampling of sea water across the Lincoln Sea. The system incorporates a commercial off the shelf CTD electronics (SBE19+ sensor package and SBE33 deck unit) to provide real-time measurement data at the surface. We designed and developed modular water sample units and custom electronics to decode the bottle firing commands and close the sample bottles. For a typical station, we land a ski-equipped deHaviland Twin Otter (DHC-6) aircraft on a suitable piece of sea-ice, drill a 12" diameter hole through the ice next to the cargo door and set up a tent to provide a reasonable working environment over the hole. A small winch with 0.1" diameter single conductor cable is mounted in the aircraft by the cargo door and a tripod supports a sheave above the hole. The CTD module is connected to the end of the wire and the water sampling modules are stacked on top as the system is lowered. For most stations, three sample modules are used to provide 12 four (4) liter sample bottles. Data collected during the down-cast is used to formulate the sampling plan which is executed on the up-cast. The system is powered by a 3,700 Watt, 120VAC gasoline generator. After collection, the sample modules are stored in passively temperature stabilized ice chests during the flight back to the logistics facility at Alert where a broad range of samples are drawn and stored for future analysis. The transport mechanism has a good track record of maintaining water samples within about two degrees of the original collection temperature which minimizes out-gassing. The system has been successfully deployed during a field program each spring starting in 2004 along a transect between the north end of Ellesmere Island (Alert, Nunavut) and the North Pole. During the eight field programs we have taken 48 stations with twelve bottles at most stations (eight at some shallow stations) and with a miss-fire rate within two percent of those achieved with traditional over-the-side CTD/rosette systems.
Sved, J A; Yu, H; Dominiak, B; Gilchrist, A S
2003-01-01
Long-range dispersal of a species may involve either a single long-distance movement from a core population or spreading via unobserved intermediate populations. Where the new populations originate as small propagules, genetic drift may be extreme and gene frequency or assignment methods may not prove useful in determining the relation between the core population and outbreak samples. We describe computationally simple resampling methods for use in this situation to distinguish between the different modes of dispersal. First, estimates of heterozygosity can be used to test for direct sampling from the core population and to estimate the effective size of intermediate populations. Second, a test of sharing of alleles, particularly rare alleles, can show whether outbreaks are related to each other rather than arriving as independent samples from the core population. The shared-allele statistic also serves as a genetic distance measure that is appropriate for small samples. These methods were applied to data on a fruit fly pest species, Bactrocera tryoni, which is quarantined from some horticultural areas in Australia. We concluded that the outbreaks in the quarantine zone came from a heterogeneous set of genetically differentiated populations, possibly ones that overwinter in the vicinity of the quarantine zone. PMID:12618417
Vaeth, Michael; Skovlund, Eva
2004-06-15
For a given regression problem it is possible to identify a suitably defined equivalent two-sample problem such that the power or sample size obtained for the two-sample problem also applies to the regression problem. For a standard linear regression model the equivalent two-sample problem is easily identified, but for generalized linear models and for Cox regression models the situation is more complicated. An approximately equivalent two-sample problem may, however, also be identified here. In particular, we show that for logistic regression and Cox regression models the equivalent two-sample problem is obtained by selecting two equally sized samples for which the parameters differ by a value equal to the slope times twice the standard deviation of the independent variable and further requiring that the overall expected number of events is unchanged. In a simulation study we examine the validity of this approach to power calculations in logistic regression and Cox regression models. Several different covariate distributions are considered for selected values of the overall response probability and a range of alternatives. For the Cox regression model we consider both constant and non-constant hazard rates. The results show that in general the approach is remarkably accurate even in relatively small samples. Some discrepancies are, however, found in small samples with few events and a highly skewed covariate distribution. Comparison with results based on alternative methods for logistic regression models with a single continuous covariate indicates that the proposed method is at least as good as its competitors. The method is easy to implement and therefore provides a simple way to extend the range of problems that can be covered by the usual formulas for power and sample size determination. Copyright 2004 John Wiley & Sons, Ltd.
Salmonella testing of pooled pre-enrichment broth cultures for screening multiple food samples.
Price, W R; Olsen, R A; Hunter, J E
1972-04-01
A method has been described for testing multiple food samples for Salmonella without loss in sensitivity. The method pools multiple pre-enrichment broth cultures into single enrichment broths. The subsequent stages of the Salmonella analysis are not altered. The method was found applicable to several dry food materials including nonfat dry milk, dried egg albumin, cocoa, cottonseed flour, wheat flour, and shredded coconut. As many as 25 pre-enrichment broth cultures were pooled without apparent loss in the sensitivity of Salmonella detection as compared to individual sample analysis. The procedure offers a simple, yet effective, way to increase sample capacity in the Salmonella testing of foods, particularly where a large proportion of samples ordinarily is negative. It also permits small portions of pre-enrichment broth cultures to be retained for subsequent individual analysis if positive tests are found. Salmonella testing of pooled pre-enrichment broths provides increased consumer protection for a given amount of analytical effort as compared to individual sample analysis.
NASA Astrophysics Data System (ADS)
Uras-Aytemiz, Nevin; Abrrey Monreal, I.; Devlin, J. Paul
2011-10-01
A simple method has been developed for the measurement of high quality FTIR spectra of aerosols of gas-hydrate nanoparticles. The application of this method enables quantitative observation of gas hydrates that form on subsecond timescales using our all-vapor approach that includes an ether catalyst rather than high pressures to promote hydrate formation. The sampling method is versatile allowing routine studies at temperatures ranging from 120 to 210 K of either a single gas or the competitive uptake of different gas molecules in small cages of the hydrates. The present study emphasizes hydrate aerosols formed by pulsing vapor mixtures into a cold chamber held at 160 or 180 K. We emphasize aerosol spectra from 6 scans recorded an average of 8 s after "instantaneous" hydrate formation as well as of the gas hydrates as they evolve with time. Quantitative aerosol data are reported and analyzed for single small-cage guests and for mixed hydrates of CO2, CH4, C2H2, N2O, N2, and air. The approach, combined with the instant formation of gas hydrates from vapors only, offers promise with respect to optimization of methods for the formation and control of gas hydrates.
Lewandowska, Aleksandra E; Macur, Katarzyna; Czaplewska, Paulina; Liss, Joanna; Łukaszuk, Krzysztof; Ołdziej, Stanisław
2017-08-04
Human follicular fluid (hFF) is a natural environment of oocyte maturation, and some components of hFF could be used to judge oocyte capability for fertilization and further development. In our pilot small-scale study three samples from four donors (12 samples in total) were analyzed to determine which hFF proteins/peptides could be used to differentiate individual oocytes and which are patient-specific. Ultrafiltration was used to fractionate hFF to high-molecular-weight (HMW) proteome (>10 kDa) and low-molecular-weight (LMW) peptidome (<10 kDa) fractions. HMW and LMW compositions were analyzed using LC-MS in SWATH data acquisition and processing methodology. In total we were able to identify 158 proteins, from which 59 were never reported before as hFF components. 55 (45 not reported before) proteins were found by analyzing LMW fraction, 67 (14 not reported before) were found by analyzing HMW fraction, and 36 were identified in both fractions of hFF. We were able to perform quantitative analysis for 72 proteins from HMW fraction of hFF. We found that concentrations of 11 proteins varied substantially among hFF samples from single donors, and those proteins are promising targets to identify biomarkers useful in oocyte quality assessment.
Azcarate, Silvana M; Savio, Marianela; Smichowski, Patricia; Martinez, Luis D; Camiña, José M; Gil, Raúl A
2015-10-01
A single-step procedure for trace elements analysis of milk samples is presented. Solubilization with small amounts of dymethylformamide (DMF) was assayed prior to inductively coupled plasma mass spectrometry (ICPMS) detection with a high efficiency sample introduction system. All main instrumental conditions were optimized in order to readily introduce the samples without matrix elimination. In order to assess and mitigate matrix effects in the determination of As, Cd, Co, Cu, Eu, Ga, Gd, Ge, Mn, Mo, Nb, Nd, Ni, Pb, Pr, Rb, Sm, S, Sr, Ta, Tb, V, Zn, and Zr, matrix matching calibration with (103)Rh as internal standard (IS) was performed. The obtained limits of detection were between 0.68 (Tb) and 30 (Zn) μg L(-1). For accuracy verification, certified Skim milk powder reference material (BCR 063R) was employed. The developed method was applied to trace elements analysis of commercially available milks. Principal components analysis was used to correlate the content of trace metals with the kind of milk, obtaining a classification according to adults, baby or baby fortified milks. The outcomes highlight a simple and fast approach that could be trustworthy for routine analysis, quality control and traceability of milks. Copyright © 2015 Elsevier B.V. All rights reserved.
Genetic Diversity of Small Eukaryotes in Lakes Differing by Their Trophic Status
Lefranc, Marie; Thénot, Aurélie; Lepère, Cécile; Debroas, Didier
2005-01-01
Small eukaryotes, cells with a diameter of less than 5 μm, are fundamental components of lacustrine planktonic systems. In this study, small-eukaryote diversity was determined by sequencing cloned 18S rRNA genes in three libraries from lakes of differing trophic status in the Massif Central, France: the oligotrophic Lake Godivelle, the oligomesotrophic Lake Pavin, and the eutrophic Lake Aydat. This analysis shows that the least diversified library was in the eutrophic lake (12 operational taxonomic units [OTUs]) and the most diversified was in the oligomesotrophic lake (26 OTUs). Certain groups were present in at least two ecosystems, while the others were specific to one lake on the sampling date. Cryptophyta, Chrysophyceae, and the strictly heterotrophic eukaryotes, Ciliophora and fungi, were identified in the three libraries. Among the small eukaryotes found only in two lakes, Choanoflagellida and environmental sequences (LKM11) were not detected in the eutrophic system whereas Cercozoa were confined to the oligomesotrophic and eutrophic lakes. Three OTUs, linked to the Perkinsozoa, were detected only in the Aydat library, where they represented 60% of the clones of the library. Chlorophyta and Haptophyta lineages were represented by a single clone and were present only in Godivelle and Pavin, respectively. Of the 127 clones studied, classical pigmented organisms (autotrophs and mixotrophs) represented only a low proportion regardless of the library's origin. This study shows that the small-eukaryote community composition may differ as a function of trophic status; certain lineages could be detected only in a single ecosystem. PMID:16204507
How large is large enough for insects? Forest fragmentation effects at three spatial scales
NASA Astrophysics Data System (ADS)
Ribas, C. R.; Sobrinho, T. G.; Schoereder, J. H.; Sperber, C. F.; Lopes-Andrade, C.; Soares, S. M.
2005-02-01
Several mechanisms may lead to species loss in fragmented habitats, such as edge and shape effects, loss of habitat and heterogeneity. Ants and crickets were sampled in 18 forest remnants in south-eastern Brazil, to test whether a group of small remnants maintains the same insect species richness as similar sized large remnants, at three spatial scales. We tested hypotheses about alpha and gamma diversity to explain the results. Groups of remnants conserve as many species of ants as a single one. Crickets, however, showed a scale-dependent pattern: at small scales there was no significant or important difference between groups of remnants and a single one, while at the larger scale the group of remnants maintained more species. Alpha diversity (local species richness) was similar in a group of remnants and in a single one, at the three spatial scales, both for ants and crickets. Gamma diversity, however, varied both with taxa (ants and crickets) and spatial scale, which may be linked to insect mobility, remnant isolation, and habitat heterogeneity. Biological characteristics of the organisms involved have to be considered when studying fragmentation effects, as well as spatial scale at which it operates. Mobility of the organisms influences fragmentation effects, and consequently conservation strategies.
NASA Technical Reports Server (NTRS)
Wolf, Michael
2012-01-01
A document describes an algorithm created to estimate the mass placed on a sample verification sensor (SVS) designed for lunar or planetary robotic sample return missions. A novel SVS measures the capacitance between a rigid bottom plate and an elastic top membrane in seven locations. As additional sample material (soil and/or small rocks) is placed on the top membrane, the deformation of the membrane increases the capacitance. The mass estimation algorithm addresses both the calibration of each SVS channel, and also addresses how to combine the capacitances read from each of the seven channels into a single mass estimate. The probabilistic approach combines the channels according to the variance observed during the training phase, and provides not only the mass estimate, but also a value for the certainty of the estimate. SVS capacitance data is collected for known masses under a wide variety of possible loading scenarios, though in all cases, the distribution of sample within the canister is expected to be approximately uniform. A capacitance-vs-mass curve is fitted to this data, and is subsequently used to determine the mass estimate for the single channel s capacitance reading during the measurement phase. This results in seven different mass estimates, one for each SVS channel. Moreover, the variance of the calibration data is used to place a Gaussian probability distribution function (pdf) around this mass estimate. To blend these seven estimates, the seven pdfs are combined into a single Gaussian distribution function, providing the final mean and variance of the estimate. This blending technique essentially takes the final estimate as an average of the estimates of the seven channels, weighted by the inverse of the channel s variance.
Minimizing inhibition of PCR-STR typing using digital agarose droplet microfluidics.
Geng, Tao; Mathies, Richard A
2015-01-01
The presence of PCR inhibitors in forensic and other biological samples reduces the amplification efficiency, sometimes resulting in complete PCR failure. Here we demonstrate a high-performance digital agarose droplet microfluidics technique for single-cell and single-molecule forensic short tandem repeat (STR) typing of samples contaminated with high concentrations of PCR inhibitors. In our multifaceted strategy, the mitigation of inhibitory effects is achieved by the efficient removal of inhibitors from the porous agarose microgel droplets carrying the DNA template through washing and by the significant dilution of targets and remaining inhibitors to the stochastic limit within the ultralow nL volume droplet reactors. Compared to conventional tube-based bulk PCR, our technique shows enhanced (20 ×, 10 ×, and 16 ×) tolerance of urea, tannic acid, and humic acid, respectively, in STR typing of GM09948 human lymphoid cells. STR profiling of single cells is not affected by small soluble molecules like urea and tannic acid because of their effective elimination from the agarose droplets; however, higher molecular weight humic acid still partially inhibits single-cell PCR when the concentration is higher than 200 ng/μL. Nevertheless, the full STR profile of 9948 male genomic DNA contaminated with 500 ng/μL humic acid was generated by pooling and amplifying beads carrying single-molecule 9948 DNA PCR products in a single secondary reaction. This superior performance suggests that our digital agarose droplet microfluidics technology is a promising approach for analyzing low-abundance DNA targets in the presence of inhibitors. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Stability of topological defects in chiral superconductors: London theory.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vakaryuk, V.
2011-12-22
This paper examines the thermodynamic stability of chiral domain walls and vortices-topological defects which can exist in chiral superconductors. Using London theory it is demonstrated that at sufficiently small applied and chiral fields the existence of domain walls and vortices in the sample is not favored and the sample's configuration is a single domain. The particular chirality of the single-domain configuration is neither favored nor disfavored by the applied field. Increasing the field leads to an entry of a domain-wall loop or a vortex into the sample. The formation of a straight domain wall is never preferred in equilibrium. Valuesmore » of the entry (critical) fields for both types of defects, as well as the equilibrium size of the domain-wall loop, are calculated. We also consider a mesoscopic chiral sample and calculate its zero-field magnetization, susceptibility, and a change in the magnetic moment due to a vortex or a domain-wall entry. We show that in the case of a soft domain wall whose energetics is dominated by the chiral current (and not by the surface tension) its behavior in mesoscopic samples is substantially different from that in the bulk case and can be used for a controllable transfer of edge excitations. The applicability of these results to Sr{sub 2}RuO{sub 4} - a tentative chiral superconductor - is discussed.« less
Stability of topological defects in chiral superconductors: London theory
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vakaryuk, Victor
2011-12-01
This paper examines the thermodynamic stability of chiral domain walls and vortices—topological defects which can exist in chiral superconductors. Using London theory it is demonstrated that at sufficiently small applied and chiral fields the existence of domain walls and vortices in the sample is not favored and the sample's configuration is a single domain. The particular chirality of the single-domain configuration is neither favored nor disfavored by the applied field. Increasing the field leads to an entry of a domain-wall loop or a vortex into the sample. The formation of a straight domain wall is never preferred in equilibrium. Valuesmore » of the entry (critical) fields for both types of defects, as well as the equilibrium size of the domain-wall loop, are calculated. We also consider a mesoscopic chiral sample and calculate its zero-field magnetization, susceptibility, and a change in the magnetic moment due to a vortex or a domain-wall entry. We show that in the case of a soft domain wall whose energetics is dominated by the chiral current (and not by the surface tension) its behavior in mesoscopic samples is substantially different from that in the bulk case and can be used for a controllable transfer of edge excitations. The applicability of these results to Sr 2 RuO 4 —a tentative chiral superconductor—is discussed.« less
Hopkins, Max; Kailasan, Shweta; Cohen, Allison; Roux, Simon; Tucker, Kimberly Pause; Shevenell, Amelia; Agbandje-McKenna, Mavis; Breitbart, Mya
2014-01-01
The small single-stranded DNA (ssDNA) bacteriophages of the subfamily Gokushovirinae were traditionally perceived as narrowly targeted, niche-specific viruses infecting obligate parasitic bacteria, such as Chlamydia. The advent of metagenomics revealed gokushoviruses to be widespread in global environmental samples. This study expands knowledge of gokushovirus diversity in the environment by developing a degenerate PCR assay to amplify a portion of the major capsid protein (MCP) gene of gokushoviruses. Over 500 amplicons were sequenced from 10 environmental samples (sediments, sewage, seawater and freshwater), revealing the ubiquity and high diversity of this understudied phage group. Residue-level conservation data generated from multiple alignments was combined with a predicted 3D structure, revealing a tendency for structurally internal residues to be more highly conserved than surface-presenting protein–protein or viral–host interaction domains. Aggregating this data set into a phylogenetic framework, many gokushovirus MCP clades contained samples from multiple environments, although distinct clades dominated the different samples. Antarctic sediment samples contained the most diverse gokushovirus communities, whereas freshwater springs from Florida were the least diverse. Whether the observed diversity is being driven by environmental factors or host-binding interactions remains an open question. The high environmental diversity of this previously overlooked ssDNA viral group necessitates further research elucidating their natural hosts and exploring their ecological roles. PMID:24694711
NASA Astrophysics Data System (ADS)
Nhalil, Hariharan; Elizabeth, Suja
2016-12-01
Highly non-linear I-V characteristics and apparent colossal electro-resistance were observed in non-charge ordered manganite Tb0.5Sr0.5MnO3 single crystal in low temperature transport measurements. Significant changes were noticed in top surface temperature of the sample as compared to its base while passing current at low temperature. By analyzing these variations, we realize that the change in surface temperature (ΔTsur) is too small to have caused by the strong negative differential resistance. A more accurate estimation of change in the sample temperature was made by back-calculating the sample temperature from the temperature variation of resistance (R-T) data (ΔTcal), which was found to be higher than ΔTsur. This result indicates that there are large thermal gradients across the sample. The experimentally derived ΔTcal is validated with the help of a simple theoretical model and estimation of Joule heating. Pulse measurements realize substantial reduction in Joule heating. With decrease in sample thickness, Joule heating effect is found to be reduced. Our studies reveal that Joule heating plays a major role in the nonlinear electrical response of Tb0.5Sr0.5MnO3. By careful management of the duty cycle and pulse current I-V measurements, Joule heating can be mitigated to a large extent.
Single-molecule analysis of steroid receptor and cofactor action in living cells
Paakinaho, Ville; Presman, Diego M.; Ball, David A.; Johnson, Thomas A.; Schiltz, R. Louis; Levitt, Peter; Mazza, Davide; Morisaki, Tatsuya; Karpova, Tatiana S.; Hager, Gordon L.
2017-01-01
Population-based assays have been employed extensively to investigate the interactions of transcription factors (TFs) with chromatin and are often interpreted in terms of static and sequential binding. However, fluorescence microscopy techniques reveal a more dynamic binding behaviour of TFs in live cells. Here we analyse the strengths and limitations of in vivo single-molecule tracking and performed a comprehensive analysis on the intranuclear dwell times of four steroid receptors and a number of known cofactors. While the absolute residence times estimates can depend on imaging acquisition parameters due to sampling bias, our results indicate that only a small proportion of factors are specifically bound to chromatin at any given time. Interestingly, the glucocorticoid receptor and its cofactors affect each other’s dwell times in an asymmetric manner. Overall, our data indicate transient rather than stable TF-cofactors chromatin interactions at response elements at the single-molecule level. PMID:28635963
Single-protein detection in crowded molecular environments in cryo-EM images
Rickgauer, J Peter; Grigorieff, Nikolaus; Denk, Winfried
2017-01-01
We present an approach to study macromolecular assemblies by detecting component proteins’ characteristic high-resolution projection patterns, calculated from their known 3D structures, in single electron cryo-micrographs. Our method detects single apoferritin molecules in vitreous ice with high specificity and determines their orientation and location precisely. Simulations show that high spatial-frequency information and—in the presence of protein background—a whitening filter are essential for optimal detection, in particular for images taken far from focus. Experimentally, we could detect small viral RNA polymerase molecules, distributed randomly among binding locations, inside rotavirus particles. Based on the currently attainable image quality, we estimate a threshold for detection that is 150 kDa in ice and 300 kDa in 100 nm thick samples of dense biological material. DOI: http://dx.doi.org/10.7554/eLife.25648.001 PMID:28467302
NASA Astrophysics Data System (ADS)
Ahmad, Habib; Sutherland, Alex; Shin, Young Shik; Hwang, Kiwook; Qin, Lidong; Krom, Russell-John; Heath, James R.
2011-09-01
Microfluidics flow-patterning has been utilized for the construction of chip-scale miniaturized DNA and protein barcode arrays. Such arrays have been used for specific clinical and fundamental investigations in which many proteins are assayed from single cells or other small sample sizes. However, flow-patterned arrays are hand-prepared, and so are impractical for broad applications. We describe an integrated robotics/microfluidics platform for the automated preparation of such arrays, and we apply it to the batch fabrication of up to eighteen chips of flow-patterned DNA barcodes. The resulting substrates are comparable in quality with hand-made arrays and exhibit excellent substrate-to-substrate consistency. We demonstrate the utility and reproducibility of robotics-patterned barcodes by utilizing two flow-patterned chips for highly parallel assays of a panel of secreted proteins from single macrophage cells.
Ahmad, Habib; Sutherland, Alex; Shin, Young Shik; Hwang, Kiwook; Qin, Lidong; Krom, Russell-John; Heath, James R.
2011-01-01
Microfluidics flow-patterning has been utilized for the construction of chip-scale miniaturized DNA and protein barcode arrays. Such arrays have been used for specific clinical and fundamental investigations in which many proteins are assayed from single cells or other small sample sizes. However, flow-patterned arrays are hand-prepared, and so are impractical for broad applications. We describe an integrated robotics/microfluidics platform for the automated preparation of such arrays, and we apply it to the batch fabrication of up to eighteen chips of flow-patterned DNA barcodes. The resulting substrates are comparable in quality with hand-made arrays and exhibit excellent substrate-to-substrate consistency. We demonstrate the utility and reproducibility of robotics-patterned barcodes by utilizing two flow-patterned chips for highly parallel assays of a panel of secreted proteins from single macrophage cells. PMID:21974603
Ahmad, Habib; Sutherland, Alex; Shin, Young Shik; Hwang, Kiwook; Qin, Lidong; Krom, Russell-John; Heath, James R
2011-09-01
Microfluidics flow-patterning has been utilized for the construction of chip-scale miniaturized DNA and protein barcode arrays. Such arrays have been used for specific clinical and fundamental investigations in which many proteins are assayed from single cells or other small sample sizes. However, flow-patterned arrays are hand-prepared, and so are impractical for broad applications. We describe an integrated robotics/microfluidics platform for the automated preparation of such arrays, and we apply it to the batch fabrication of up to eighteen chips of flow-patterned DNA barcodes. The resulting substrates are comparable in quality with hand-made arrays and exhibit excellent substrate-to-substrate consistency. We demonstrate the utility and reproducibility of robotics-patterned barcodes by utilizing two flow-patterned chips for highly parallel assays of a panel of secreted proteins from single macrophage cells. © 2011 American Institute of Physics
Ishibashi, Ryo; Mawatari, Kazuma; Kitamori, Takehiko
2012-04-23
The rapidly developing interest in nanofluidic analysis, which is used to examine liquids ranging in amounts from the attoliter to the femtoliter scale, correlates with the recent interest in decreased sample amounts, such as in the field of single-cell analysis. For general nanofluidic analysis, the fact that a pressure-driven flow does not limit the choice of solvents (aqueous or organic) is important. This study shows the first pressure-driven liquid chromatography technique that enables separation of atto- to femtoliter sample volumes, with a high separation efficiency within a few seconds. The apparent diffusion coefficient measurement of the unretentive sample suggests that there is no increase in the viscosity of toluene in the extended nanospace, unlike in aqueous solvents. Evaluation of the normal phase separation, therefore, should involve only the examination of the effect of the small size of the extended nanospace. Compared to a conventionally packed high-performance liquid chromatography column, the separation here results in a faster separation (4 s) by 2 orders of magnitude, a smaller injection volume (10(0) fL) by 9 orders, and a higher separation efficiency (440,000 plates/m) by 1 order. Moreover, the separation behavior agrees with the theory showing that this high efficiency was due to the small and controlled size of the separation channel, where the diffusion through the channel depth direction is fast enough to be neglected. Our chip-based platform should allow direct and real-time analysis or screening of ultralow volume of sample. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Fisher, Kevin E.; Zhang, Linsheng; Wang, Jason; Smith, Geoffrey H.; Newman, Scott; Schneider, Thomas M.; Pillai, Rathi N.; Kudchadkar, Ragini R.; Owonikoko, Taofeek K.; Ramalingam, Suresh S.; Lawson, David H.; Delman, Keith A.; El-Rayes, Bassel F.; Wilson, Malania M.; Sullivan, H. Clifford; Morrison, Annie S.; Balci, Serdar; Adsay, N. Volkan; Gal, Anthony A.; Sica, Gabriel L.; Saxe, Debra F.; Mann, Karen P.; Hill, Charles E.; Khuri, Fadlo R.; Rossi, Michael R.
2017-01-01
We tested and clinically validated a targeted next-generation sequencing (NGS) mutation panel using 80 formalin-fixed, paraffin-embedded (FFPE) tumor samples. Forty non-small cell lung carcinoma (NSCLC), 30 melanoma, and 30 gastrointestinal (12 colonic, 10 gastric, and 8 pancreatic adenocarcinoma) FFPE samples were selected from laboratory archives. After appropriate specimen and nucleic acid quality control, 80 NGS libraries were prepared using the Illumina TruSight tumor (TST) kit and sequenced on the Illumina MiSeq. Sequence alignment, variant calling, and sequencing quality control were performed using vendor software and laboratory-developed analysis workflows. TST generated ≥500× coverage for 98.4% of the 13,952 targeted bases. Reproducible and accurate variant calling was achieved at ≥5% variant allele frequency with 8 to 12 multiplexed samples per MiSeq flow cell. TST detected 112 variants overall, and confirmed all known single-nucleotide variants (n = 27), deletions (n = 5), insertions (n = 3), and multinucleotide variants (n = 3). TST detected at least one variant in 85.0% (68/80), and two or more variants in 36.2% (29/80), of samples. TP53 was the most frequently mutated gene in NSCLC (13 variants; 13/32 samples), gastrointestinal malignancies (15 variants; 13/25 samples), and overall (30 variants; 28/80 samples). BRAF mutations were most common in melanoma (nine variants; 9/23 samples). Clinically relevant NGS data can be obtained from routine clinical FFPE solid tumor specimens using TST, benchtop instruments, and vendor-supplied bioinformatics pipelines. PMID:26801070
Determination of the optimal sample size for a clinical trial accounting for the population size.
Stallard, Nigel; Miller, Frank; Day, Simon; Hee, Siew Wan; Madan, Jason; Zohar, Sarah; Posch, Martin
2017-07-01
The problem of choosing a sample size for a clinical trial is a very common one. In some settings, such as rare diseases or other small populations, the large sample sizes usually associated with the standard frequentist approach may be infeasible, suggesting that the sample size chosen should reflect the size of the population under consideration. Incorporation of the population size is possible in a decision-theoretic approach either explicitly by assuming that the population size is fixed and known, or implicitly through geometric discounting of the gain from future patients reflecting the expected population size. This paper develops such approaches. Building on previous work, an asymptotic expression is derived for the sample size for single and two-arm clinical trials in the general case of a clinical trial with a primary endpoint with a distribution of one parameter exponential family form that optimizes a utility function that quantifies the cost and gain per patient as a continuous function of this parameter. It is shown that as the size of the population, N, or expected size, N∗ in the case of geometric discounting, becomes large, the optimal trial size is O(N1/2) or O(N∗1/2). The sample size obtained from the asymptotic expression is also compared with the exact optimal sample size in examples with responses with Bernoulli and Poisson distributions, showing that the asymptotic approximations can also be reasonable in relatively small sample sizes. © 2016 The Author. Biometrical Journal published by WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Study of the atmospheric aerosol composition in equatorial Africa using PIXE as analytical technique
NASA Astrophysics Data System (ADS)
Maenhaut, W.; Akilimali, K.
1987-03-01
Small Nuclepore total filter holders and a single orifice 8-stage cascade impactor were used to collect atmospheric aerosol samples in Kinshasa, Zaire, and Butare, Rwanda. The samples were analyzed for about 20 elements by means of the PIXE technique. The results obtained for parallel samples, taken with two total filter holders and one cascade impactor, were generally in excellent agreement, suggesting that the different samplers collected very similar aerosol particle populations. Most elements were associated with a crustal dust dispersion source, which may include road dust dispersal. The Butare samples, particularly those collected during the night, were significantly influenced by biomass burning, as was deduced from enhanced filter blackness and noncrustal K levels. The pyrogenic component also contained P, S, Mn and Rb. Br and Pb were highly enriched at both locations, indicating that automotive sources had a strong influence on the aerosol composition.
Sampling and analysis for radon-222 dissolved in ground water and surface water
DeWayne, Cecil L.; Gesell, T.F.
1992-01-01
Radon-222 is a naturally occurring radioactive gas in the uranium-238 decay series that has traditionally been called, simply, radon. The lung cancer risks associated with the inhalation of radon decay products have been well documented by epidemiological studies on populations of uranium miners. The realization that radon is a public health hazard has raised the need for sampling and analytical guidelines for field personnel. Several sampling and analytical methods are being used to document radon concentrations in ground water and surface water worldwide but no convenient, single set of guidelines is available. Three different sampling and analytical methods - bubbler, liquid scintillation, and field screening - are discussed in this paper. The bubbler and liquid scintillation methods have high accuracy and precision, and small analytical method detection limits of 0.2 and 10 pCi/l (picocuries per liter), respectively. The field screening method generally is used as a qualitative reconnaissance tool.
Identifying Etiological Agents Causing Diarrhea in Low Income Ecuadorian Communities
Vasco, Gabriela; Trueba, Gabriel; Atherton, Richard; Calvopiña, Manuel; Cevallos, William; Andrade, Thamara; Eguiguren, Martha; Eisenberg, Joseph N. S.
2014-01-01
Continued success in decreasing diarrheal disease burden requires targeted interventions. To develop such interventions, it is crucial to understand which pathogens cause diarrhea. Using a case-control design we tested stool samples, collected in both rural and urban Ecuador, for 15 pathogenic microorganisms. Pathogens were present in 51% of case and 27% of control samples from the urban community, and 62% of case and 18% of control samples collected from the rural community. Rotavirus and Shigellae were associated with diarrhea in the urban community; co-infections were more pathogenic than single infection; Campylobacter and Entamoeba histolytica were found in large numbers in cases and controls; and non-typhi Salmonella and enteropathogenic Escherichia coli were not found in any samples. Consistent with the Global Enteric Multicenter Study, focused in south Asia and sub-Saharan Africa, we found that in Ecuador a small group of pathogens accounted for a significant amount of the diarrheal disease burden. PMID:25048373
Experimental light scattering by small particles: system design and calibration
NASA Astrophysics Data System (ADS)
Maconi, Göran; Kassamakov, Ivan; Penttilä, Antti; Gritsevich, Maria; Hæggström, Edward; Muinonen, Karri
2017-06-01
We describe a setup for precise multi-angular measurements of light scattered by mm- to μm-sized samples. We present a calibration procedure that ensures accurate measurements. Calibration is done using a spherical sample (d = 5 mm, n = 1.517) fixed on a static holder. The ultimate goal of the project is to allow accurate multi-wavelength measurements (the full Mueller matrix) of single-particle samples which are levitated ultrasonically. The system comprises a tunable multimode Argon-krypton laser, with 12 wavelengths ranging from 465 to 676 nm, a linear polarizer, a reference photomultiplier tube (PMT) monitoring beam intensity, and several PMT:s mounted radially towards the sample at an adjustable radius. The current 150 mm radius allows measuring all azimuthal angles except for ±4° around the backward scattering direction. The measurement angle is controlled by a motor-driven rotational stage with an accuracy of 15'.
A technique for extracting blood samples from mice in fire toxicity tests
NASA Technical Reports Server (NTRS)
Bucci, T. J.; Hilado, C. J.; Lopez, M. T.
1976-01-01
The extraction of adequate blood samples from moribund and dead mice has been a problem because of the small quantity of blood in each animal and the short time available between the animals' death and coagulation of the blood. These difficulties are particularly critical in fire toxicity tests because removal of the test animals while observing proper safety precautions for personnel is time-consuming. Techniques for extracting blood samples from mice were evaluated, and a technique was developed to obtain up to 0.8 ml of blood from a single mouse after death. The technique involves rapid exposure and cutting of the posterior vena cava and accumulation of blood in the peritoneal space. Blood samples of 0.5 ml or more from individual mice have been consistently obtained as much as 16 minutes after apparent death. Results of carboxyhemoglobin analyses of blood appeared reproducible and consistent with carbon monoxide concentrations in the exposure chamber.
Bell, Richard W.; Davis, Jerri V.; Femmer, Suzanne R.; Joseph, Robert L.
1997-01-01
Organic-compound samples, including pesticides and semi-volatiles, were collected from 1992-95 at 43 surface-water and 27 bed-sediment and biological-tissue sampling sites within the Ozark Plateaus National Water-Quality Assessment Program study unit. Most surface-water, bed-sediment, and biological-tissue sites have drainage basins predominantly in the Springfield and Salem Plateaus. At most surface-water sampling sites, one to three pesticide samples were collected in the spring and early summer of 1994 and 1995; two sites had additional samples collected either weekly, biweekly, or monthly from February 1994 through December 1994. At most bed-sediment and biological-tissue sampling sites, a single organic-compounds sample was collected. Agricultural pesticide use was approximately 4.9 million pounds of active ingredients per year from 1987-91 in the study unit and was generally greatest in the Springfield and Salem Plateaus pasturelands and in the Osage Plains and Mississippi Alluvial Plain cropland areas. The most frequently applied pesticide in the study unit was 2,4-D. Atrazine was the second most frequently applied pesticide. Corn, pasture, rice, sorghum, and soybeans received approximately 85 percent of the pesticides applied within the study unit. The highest pesticide application rate occurred on these crops in the Mississippi Alluvial and Osage Plains. Pastureland was the crop type that received the greatest amount of pesticides in 53 of the 96 counties in the study unit. The most commonly detected herbicide (63 samples) in surface water was atrazine. Five other pesticides--desethylatrazine, tebuthiuron, prometon, metolachlor, and simazine--were detected in 15 or more samples. The most commonly detected insecticide (13 samples) was p,p'-DDE. Two other insecticides, diazinon and cis-permethrin, were detected in seven or more samples. Pesticides were detected at 39 surface-water sites; samples collected at Yocum Creek near Oak Grove, Ark. had the most pesticide detections (13). Seventeen other sites had samples with six or more pesticide detections. Analysis of pesticide data collected at surface-water sites indicates that the largest variety of different pesticides detected (18) was in small, agricultural drainage basins; the largest percentage of detections of a single pesticide (about 80) was in medium, agricultural basins. Pesticide concentrations were small, and in most cases, at or near the detection limit. Maximum concentrations ranged from 0.001 to 0.007 micrograms per liter (mg/L) at small, forest sites; 0.001 to 0.029 mg/L at medium, forest sites; 0.001 to 0.079 mg/L at small, agricultural sites; and 0.003 to 0.29 mg/L at medium, agricultural sites. Pesticides were detected significantly more often in medium, agricultural basins in the Springfield Plateau. The most commonly detected (13 samples) organic compound in bed sediment, in concentrations noticeably above background levels, was 2,6-dimethylnaphthalene; the maximum concentration of 2,6-dimethylnaphthalene was 130 micrograms per kilogram. Seventeen or more compounds were detected in bed-sediment samples collected at three sites. Four compounds were detected in biological-tissue samples: p,p'-DDT in Corbicula fluminea (Asiatic clam) tissue collected at the Osage River near St. Thomas, Mo. and cis-chlordane, trans-chlordane, and trans-nonachlor in C. fluminea tissue collected at the James River near Boaz, Mo. Organic compounds collected at surface-water, bed-sediment, or biological-tissue sampling sites were not detected in concentrations that exceeded any health criteria or standards. Based on this information, organic compounds do not pose any widespread or persistent problems in the study unit.
Liu, Xiaojing; Locasale, Jason W
2017-04-01
Metabolomics generates a profile of small molecules that are derived from cellular metabolism and can directly reflect the outcome of complex networks of biochemical reactions, thus providing insights into multiple aspects of cellular physiology. Technological advances have enabled rapid and increasingly expansive data acquisition with samples as small as single cells; however, substantial challenges in the field remain. In this primer we provide an overview of metabolomics, especially mass spectrometry (MS)-based metabolomics, which uses liquid chromatography (LC) for separation, and discuss its utilities and limitations. We identify and discuss several areas at the frontier of metabolomics. Our goal is to give the reader a sense of what might be accomplished when conducting a metabolomics experiment, now and in the near future. Copyright © 2017 Elsevier Ltd. All rights reserved.
High pressure synthesis, crystal growth and magnetic properties of TiOF
NASA Astrophysics Data System (ADS)
Cumby, J.; Burchell, M. B.; Attfield, J. P.
2018-06-01
Polycrystalline samples of TiOF have been prepared at 1300 °C and 8 GPa, with small single crystals grown at the same conditions. The crystal structure remains tetragonal rutile-type down to at least 90 K (space group P42/mnm, a = 4.6533 (2) Å and c = 3.0143 (2) Å at 90 K) and the Ti(O,F)6 octahedra are slightly compressed, consistent with Jahn-Teller distortion of 3d1 Ti3+. Diffuse scattering reveals disordered structural correlations that may arise from local cis-order of oxide anions driven by covalency. TiOF is paramagnetic down to 5 K and observation of a small paramagnetic moment and a substantial Pauli term indicates that the d-electrons are partially delocalised.
Temperature Dependent Magnetoresistance of CeCu2Si2 up to 60 T [Proposal: P14728
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stritzinger, Laurel Elaine Winter; Lai, Y.; Mcdonald, Ross David
2017-03-23
We recently investigated the chemical substitution series CeCu2Si2-xPx, for x = 0, 0.01, and 0.14, using a contactless tunnel diode oscillator technique. These measurements revealed previously unreported Shubnikov-de Haas oscillations above 45 T with an unusual temperature dependence that could potentially be explained by a high magnetic field transition. To investigate this possible transition, magnetoresistance measurements were desired. However, initial magnetoresistance measurements on CeCu2Si2 showed poor signal-to-noise due to the small value of the sample's resistivity. To overcome this obstacle, we performed micro-structuring of a single crystal specimen to increase the sample's resistance.
A multicolor imaging pyrometer
NASA Technical Reports Server (NTRS)
Frish, Michael B.; Frank, Jonathan H.
1989-01-01
A multicolor imaging pyrometer was designed for accurately and precisely measuring the temperature distribution histories of small moving samples. The device projects six different color images of the sample onto a single charge coupled device array that provides an RS-170 video signal to a computerized frame grabber. The computer automatically selects which one of the six images provides useful data, and converts that information to a temperature map. By measuring the temperature of molten aluminum heated in a kiln, a breadboard version of the device was shown to provide high accuracy in difficult measurement situations. It is expected that this pyrometer will ultimately find application in measuring the temperature of materials undergoing radiant heating in a microgravity acoustic levitation furnace.
A multicolor imaging pyrometer
NASA Astrophysics Data System (ADS)
Frish, Michael B.; Frank, Jonathan H.
1989-06-01
A multicolor imaging pyrometer was designed for accurately and precisely measuring the temperature distribution histories of small moving samples. The device projects six different color images of the sample onto a single charge coupled device array that provides an RS-170 video signal to a computerized frame grabber. The computer automatically selects which one of the six images provides useful data, and converts that information to a temperature map. By measuring the temperature of molten aluminum heated in a kiln, a breadboard version of the device was shown to provide high accuracy in difficult measurement situations. It is expected that this pyrometer will ultimately find application in measuring the temperature of materials undergoing radiant heating in a microgravity acoustic levitation furnace.
Multiplex Immunoassay Profiling of Hormones Involved in Metabolic Regulation.
Stephen, Laurie; Guest, Paul C
2018-01-01
Multiplex immunoassays are used for rapid profiling of biomarker proteins and small molecules in biological fluids. The advantages over single immunoassays include lower sample consumption, cost, and labor. This chapter details a protocol to develop a 5-plex assay for glucagon-like peptide 1, growth hormone, insulin, leptin, and thyroid-stimulating hormone on the Luminex ® platform. The results of the analysis of insulin in normal control subjects are given due to the important role of this hormone in nutritional programming diseases.
Epidermal growth factor receptor mutation in gastric cancer.
Liu, Zhimin; Liu, Lina; Li, Mei; Wang, Zhaohui; Feng, Lu; Zhang, Qiuping; Cheng, Shihua; Lu, Shen
2011-04-01
Epidermal growth factor receptor (EGFR) and Kirsten-RAS (KRAS) mutations have been identified as predictors of response to EGFR tyrosine kinase inhibitors (TKIs) in non-small cell lung cancer. We aimed to screen the mutations of both genes in gastric carcinoma to detect the suitability of EGFR TKIs for patients with gastric carcinoma. We screened EGFR mutation in exons 19-21 and KRAS mutation in exon 2 in 58 gastric adenocarcinomas from China using high resolution melting analysis (HRMA). Positive samples were confirmed by DNA sequencing. Three EGFR missense mutations (5.2%) and 22 single nucleotide polymorphisms (SNP, Q787Q, 37.9%) were identified. To our knowledge, we report for the first time three mutation patterns of EGFR, Y801C, L858R and G863D, in gastric carcinoma. Two samples with EGFR mutation were mucinous adenocarcinoma. These three samples were collected from male patients aged over 75 years old. The frequency of KRAS mutation was 10.3% (6/58). The exclusiveness of EGFR and KRAS mutations was proven for the first time in gastric cancer. Gastric carcinoma of the mucinous adenocarcinoma type collected from older male patients may harbour EGFR mutations. The small subset of gastric adenocarcinoma patients may respond to EGFR TKIs.
Seven common mistakes in population genetics and how to avoid them.
Meirmans, Patrick G
2015-07-01
As the data resulting from modern genotyping tools are astoundingly complex, genotyping studies require great care in the sampling design, genotyping, data analysis and interpretation. Such care is necessary because, with data sets containing thousands of loci, small biases can easily become strongly significant patterns. Such biases may already be present in routine tasks that are present in almost every genotyping study. Here, I discuss seven common mistakes that can be frequently encountered in the genotyping literature: (i) giving more attention to genotyping than to sampling, (ii) failing to perform or report experimental randomization in the laboratory, (iii) equating geopolitical borders with biological borders, (iv) testing significance of clustering output, (v) misinterpreting Mantel's r statistic, (vi) only interpreting a single value of k and (vii) forgetting that only a small portion of the genome will be associated with climate. For every of those issues, I give some suggestions how to avoid the mistake. Overall, I argue that genotyping studies would benefit from establishing a more rigorous experimental design, involving proper sampling design, randomization and better distinction of a priori hypotheses and exploratory analyses. © 2015 John Wiley & Sons Ltd.
Principles and Applications of the qPlus Sensor
NASA Astrophysics Data System (ADS)
Giessibl, Franz J.
The concept of the atomic force microscope (AFM) is a very simple one: map the surface of a sample by a sharp probe that scans over the surface similar to the finger of a blind person that reads Braille characters. In AFM, the role of that finger is taken by the probe tip that senses the presence of the sample surface by detecting the force between the tip of the probe and a sample. The qPlus sensor is a self sensing cantilever based on a quartz tuning fork that supplements the traditional microfabricated cantilevers made of silicon. Quartz tuning forks are used in the watch industry in quantities of billions annually, with the positive effects on quality and perfection. Three properties of these quartz-based sensors simplify the AFM significantly: (1) the piezoelectricity of quartz allows simple self sensing, (2) the mechanical properties of quartz show very small variations with temperature, and (3) the given stiffness of many quartz tuning forks is close to the ideal stiffness of cantilevers. The key properties of the qPlus sensor are a large stiffness that allows small amplitude operation, the large size that allows to mount single-crystal probe tips, and the self-sensing piezoelectric detection mechanism.
Tangchaikeeree, Tienrat; Polpanich, Duangporn; Elaissari, Abdelhamid; Jangpatarapongsa, Kulachart
2017-10-01
Colloidal magnetic particles (MPs) have been developed in association with molecular diagnosis for several decades. MPs have the great advantage of easy manipulation using a magnet. In nucleic acid detection, these particles can act as a capture support for rapid and simple biomolecule separation. The surfaces of MPs can be modified by coating with various polymer materials to provide functionalization for different applications. The use of MPs enhances the sensitivity and specificity of detection due to the specific activity on the surface of the particles. Practical applications of MPs demonstrate greater efficiency than conventional methods. Beyond traditional detection, MPs have been successfully adopted as a smart carrier in microfluidic and lab-on-a-chip biosensors. The versatility of MPs has enabled their integration into small single detection units. MPs-based biosensors can facilitate rapid and highly sensitive detection of very small amounts of a sample. In this review, the application of MPs to the detection of nucleic acids, from sample preparation to analytical readout systems, is described. State-of-the-art integrated microsystems containing microfluidic and lab-on-a-chip biosensors for the nucleic acid detection are also addressed. Copyright © 2017 Elsevier B.V. All rights reserved.
Marcus, Hani J; Seneci, Carlo A; Hughes-Hallett, Archie; Cundy, Thomas P; Nandi, Dipankar; Yang, Guang-Zhong; Darzi, Ara
2016-04-01
Surgical approaches such as transanal endoscopic microsurgery, which utilize small operative working spaces, and are necessarily single-port, are particularly demanding with standard instruments and have not been widely adopted. The aim of this study was to compare simultaneously surgical performance in single-port versus multiport approaches, and small versus large working spaces. Ten novice, 4 intermediate, and 1 expert surgeons were recruited from a university hospital. A preclinical randomized crossover study design was implemented, comparing performance under the following conditions: (1) multiport approach and large working space, (2) multiport approach and intermediate working space, (3) single-port approach and large working space, (4) single-port approach and intermediate working space, and (5) single-port approach and small working space. In each case, participants performed a peg transfer and pattern cutting tasks, and each task repetition was scored. Intermediate and expert surgeons performed significantly better than novices in all conditions (P < .05). Performance in single-port surgery was significantly worse than multiport surgery (P < .01). In multiport surgery, there was a nonsignificant trend toward worsened performance in the intermediate versus large working space. In single-port surgery, there was a converse trend; performances in the intermediate and small working spaces were significantly better than in the large working space. Single-port approaches were significantly more technically challenging than multiport approaches, possibly reflecting loss of instrument triangulation. Surprisingly, in single-port approaches, in which triangulation was no longer a factor, performance in large working spaces was worse than in intermediate and small working spaces. © The Author(s) 2015.
Characterization of single grain by observing magnetic ejection and rotation in microgravity
NASA Astrophysics Data System (ADS)
Uyeda, Chiaki
A simple and nondestructive method to perform material identification on a single particle is desired in various fields of material science that is concerned with nano-sized particles. We propose a method of identification based on magnetization data, which is obtained from field-induced translation and rotation in microgravity [1]. Material identification is possible from magnetization data because an intrinsic value of susceptibility and anisotropy is assigned to every material according to a data book that compiles the published values [2]. Preliminary ob-servation on free translational motion due to repulsive field-gradient force was reported for mm-sized crystal of corundum [1] and other oxides. Rotational oscillation was observed for various diamagnetic single-crystals in homogeneous field [2]. In order to examine the capability of the above-mentioned material characterization, translation and rotation motion was observed for sub-millimeter-sized quartz, calcite and forsterite in microgravity condition (MGLAB, Japan, duration: 4.5s). It is expected from motional equations that the 2 motions are independent to mass of particles, In a given field distribution, acceleration of translation is expected to be uniquely determined from intrinsic susceptibility of sample. The above properties are exam-ined in the present work by varying experimental parameters. It is noted that observation of the above two motions in microgravity serve as a useful method to detect magnetization of single small particles, be cause the system is free of both sample holder and mass measure-ment. It is expected that magnetization can be measured on a isolated small sample down to nano-level, in condition that motion of the sample is observable. For both susceptibility and anisotropy, range of observed values using microgravity cover the range of compiled published values [2]. Hence material identification is possible for solid material in general. Diamagnetic magnetization and its anisotropy derive from three-dimensional distribution of localized elec-trons. In case of organic materials, origin of magnetization was consistently explained in terms of molecular-orbital method. The investigation was not performed on oxide crystals partly because the experimental values were not reported for most of the material[4]. Improvement of sensitivity using microgravity condition was necessary in order to understand the overall relationship between electron distribution and anisotropy of susceptibility. [1] K. Hisayoshi et al: J.Phys.: Conf. Ser., (2009) 156 012021. [2] R. Guputa: "Landort Bornstein" New Series II (1983) 445. [3]C.Uyeda et al.(206)Jpn.J.appl.Phys.43 L124 [4]C.Uyeda et al.: Appl. Phys. Lett. (1983) 094103.
Maurice, Matthew J; Ramirez, Daniel; Kaouk, Jihad H
2017-04-01
Robotic single-site retroperitoneal renal surgery has the potential to minimize the morbidity of standard transperitoneal and multiport approaches. Traditionally, technological limitations of non-purpose-built robotic platforms have hindered the application of this approach. To assess the feasibility of retroperitoneal renal surgery using a new purpose-built robotic single-port surgical system. This was a preclinical study using three male cadavers to assess the feasibility of the da Vinci SP1098 surgical system for robotic laparoendoscopic single-site (R-LESS) retroperitoneal renal surgery. We used the SP1098 to perform retroperitoneal R-LESS radical nephrectomy (n=1) and bilateral partial nephrectomy (n=4) on the anterior and posterior surfaces of the kidney. Improvements unique to this system include enhanced optics and intelligent instrument arm control. Access was obtained 2cm anterior and inferior to the tip of the 12th rib using a novel 2.5-cm robotic single-port system that accommodates three double-jointed articulating robotic instruments, an articulating camera, and an assistant port. The primary outcome was the technical feasibility of the procedures, as measured by the need for conversion to standard techniques, intraoperative complications, and operative times. All cases were completed without the need for conversion. There were no intraoperative complications. The operative time was 100min for radical nephrectomy, and the mean operative time was 91.8±18.5min for partial nephrectomy. Limitations include the preclinical model, the small sample size, and the lack of a control group. Single-site retroperitoneal renal surgery is feasible using the latest-generation SP1098 robotic platform. While the potential of the SP1098 appears promising, further study is needed for clinical evaluation of this investigational technology. In an experimental model, we used a new robotic system to successfully perform major surgery on the kidney through a single small incision without entering the abdomen. Copyright © 2016. Published by Elsevier B.V.
Examination of Duct Physiology in the Human Mammary Gland
Mills, Dixie; Gomberawalla, Ameer; Gordon, Eva J.; Tondre, Julie; Nejad, Mitra; Nguyen, Tinh; Pogoda, Janice M.; Rao, Jianyu; Chatterton, Robert; Henning, Susanne; Love, Susan M.
2016-01-01
Background The human breast comprise several ductal systems, or lobes, which contain a small amount of fluid containing cells, hormones, proteins and metabolites. The complex physiology of these ducts is likely a contributing factor to the development of breast cancer, especially given that the vast majority of breast cancers begin in a single lobular unit. Methods We examined the levels of total protein, progesterone, estradiol, estrone sulfate, dehydroepiandrosterone sulfate, and macrophages in ductal fluid samples obtained from 3 ducts each in 78 women, sampled twice over a 6 month period. Samples were processed for both cytological and molecular analysis. Intraclass correlation coefficients and mixed models were utilized to identify significant data. Results We found that the levels of these ductal fluid components were generally uncorrelated among ducts within a single breast and over time, suggesting that each lobe within the breast has a distinct physiology. However, we also found that estradiol was more correlated in women who were nulliparous or produced nipple aspirate fluid. Conclusions Our results provide evidence that the microenvironment of any given lobular unit is unique to that individual unit, findings that may provide clues about the initiation and development of ductal carcinomas. PMID:27073976
Hopfer, Helene; Jodari, Farman; Negre-Zakharov, Florence; Wylie, Phillip L; Ebeler, Susan E
2016-05-25
Demand for aromatic rice varieties (e.g., Basmati) is increasing in the US. Aromatic varieties typically have elevated levels of the aroma compound 2-acetyl-1-pyrroline (2AP). Due to its very low aroma threshold, analysis of 2AP provides a useful screening tool for rice breeders. Methods for 2AP analysis in rice should quantitate 2AP at or below sensory threshold level, avoid artifactual 2AP generation, and be able to analyze single rice kernels in cases where only small sample quantities are available (e.g., breeding trials). We combined headspace solid phase microextraction with gas chromatography tandem mass spectrometry (HS-SPME-GC-MS/MS) for analysis of 2AP, using an extraction temperature of 40 °C and a stable isotopologue as internal standard. 2AP calibrations were linear between the concentrations of 53 and 5380 pg/g, with detection limits below the sensory threshold of 2AP. Forty-eight aromatic and nonaromatic, milled rice samples from three harvest years were screened with the method for their 2AP content, and overall reproducibility, observed for all samples, ranged from 5% for experimental aromatic lines to 33% for nonaromatic lines.
Identification of pathogen genomic variants through an integrated pipeline
2014-01-01
Background Whole-genome sequencing represents a powerful experimental tool for pathogen research. We present methods for the analysis of small eukaryotic genomes, including a streamlined system (called Platypus) for finding single nucleotide and copy number variants as well as recombination events. Results We have validated our pipeline using four sets of Plasmodium falciparum drug resistant data containing 26 clones from 3D7 and Dd2 background strains, identifying an average of 11 single nucleotide variants per clone. We also identify 8 copy number variants with contributions to resistance, and report for the first time that all analyzed amplification events are in tandem. Conclusions The Platypus pipeline provides malaria researchers with a powerful tool to analyze short read sequencing data. It provides an accurate way to detect SNVs using known software packages, and a novel methodology for detection of CNVs, though it does not currently support detection of small indels. We have validated that the pipeline detects known SNVs in a variety of samples while filtering out spurious data. We bundle the methods into a freely available package. PMID:24589256
Small Vocabulary Recognition Using Surface Electromyography in an Acoustically Harsh Environment
NASA Technical Reports Server (NTRS)
Betts, Bradley J.; Jorgensen, Charles
2005-01-01
This paper presents results of electromyographic-based (EMG-based) speech recognition on a small vocabulary of 15 English words. The work was motivated in part by a desire to mitigate the effects of high acoustic noise on speech intelligibility in communication systems used by first responders. Both an off-line and a real-time system were constructed. Data were collected from a single male subject wearing a fireghter's self-contained breathing apparatus. A single channel of EMG data was used, collected via surface sensors at a rate of 104 samples/s. The signal processing core consisted of an activity detector, a feature extractor, and a neural network classifier. In the off-line phase, 150 examples of each word were collected from the subject. Generalization testing, conducted using bootstrapping, produced an overall average correct classification rate on the 15 words of 74%, with a 95% confidence interval of [71%, 77%]. Once the classifier was trained, the subject used the real-time system to communicate and to control a robotic device. The real-time system was tested with the subject exposed to an ambient noise level of approximately 95 decibels.
Strength statistics of single crystals and metallic glasses under small stressed volumes
Gao, Yanfei; Bei, Hongbin
2016-05-13
It has been well documented that plastic deformation of crystalline and amorphous metals/alloys shows a general trend of “smaller is stronger”. The majority of the experimental and modeling studies along this line have been focused on finding and reasoning the scaling slope or exponent in the logarithmic plot of strength versus size. In contrast to this view, here we show that the universal picture should be the thermally activated nucleation mechanisms in small stressed volume, the stochastic behavior as to find the weakest links in intermediate sizes of the stressed volume, and the convolution of these two mechanisms with respectmore » to variables such as indenter radius in nanoindentation pop-in, crystallographic orientation, pre-strain level, sample length as in uniaxial tests, and others. Furthermore, experiments that cover the entire spectrum of length scales and a unified model that treats both thermal activation and spatial stochasticity have discovered new perspectives in understanding and correlating the strength statistics in a vast of observations in nanoindentation, micro-pillar compression, and fiber/whisker tension tests of single crystals and metallic glasses.« less
Yung, Tony K F; Chan, K C Allen; Mok, Tony S K; Tong, Joanna; To, Ka-Fai; Lo, Y M Dennis
2009-03-15
We aim to develop a digital PCR-based method for the quantitative detection of the two common epidermal growth factor receptor (EGFR) mutations (in-frame deletion at exon 19 and L858R at exon 21) in the plasma and tumor tissues of patients suffering from non-small cell lung cancers. These two mutations account for >85% of clinically important EGFR mutations associated with responsiveness to tyrosine kinase inhibitors. DNA samples were analyzed using a microfluidics system that simultaneously performed 9,180 PCRs at nanoliter scale. A single-mutant DNA molecule in a clinical specimen could be detected and the quantities of mutant and wild-type sequences were precisely determined. Exon 19 deletion and L858R mutation were detectable in 6 (17%) and 9 (26%) of 35 pretreatment plasma samples, respectively. When compared with the sequencing results of the tumor samples, the sensitivity and specificity of plasma EGFR mutation analysis were 92% and 100%, respectively. The plasma concentration of the mutant sequences correlated well with the clinical response. Decreased concentration was observed in all patients with partial or complete clinical remission, whereas persistence of mutation was observed in a patient with cancer progression. In one patient, tyrosine kinase inhibitor was stopped after an initial response and the tumor-associated EGFR mutation reemerged 4 weeks after stopping treatment. The sensitive detection and accurate quantification of low abundance EGFR mutations in tumor tissues and plasma by microfluidics digital PCR would be useful for predicting treatment response, monitoring disease progression and early detection of treatment failure associated with acquired drug resistance.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lyagaeva, Yu. G.; Vdovin, G. K.; Nikolaenko, I. V.
2016-06-15
The effect of the content of CuO additive on the sinterability, phase composition, microstructure, and electrical properties of BaCe{sub 0.5}Zr{sub 0.3}Y{sub 0.2}O{sub 3–δ} proton-conducting material is studied. Ceramic samples were produced by the citrate–nitrate synthesis method with the addition of 0, 0.25, 0.5, and 1% CuO. It is shown that the relative density of the samples containing 0.5 and 1% CuO is higher than 94% at a sintering temperature of 1450°C, whereas the relative density of the material is no higher than 85% at a lower content of the sintering additive. From the data of X-ray diffraction analysis and scanningmore » electron microscopy, it is established that the introduction of a small CuO content (0.25%) is inadequate for single-phase and high-dense ceramics to be formed. The conductivity and scanning electron microscopy data show that the sample with BaCe{sub 0.5}Zr{sub 0.3}Y{sub 0.2}O{sub 3–δ} + 0.5% CuO composition possesses high total and ionic conductivities as well as a high degree of microstructural stability after hydrogen reduction of the ceramics. The citrate–nitrate method modified by the introduction of a small CuO content can be recommended for the production of single-phase, gas-tight, and high-conductivity electrolytes based on both BaCeO{sub 3} and BaZrO{sub 3}.« less
Tumor Heterogeneity, Single-Cell Sequencing, and Drug Resistance.
Schmidt, Felix; Efferth, Thomas
2016-06-16
Tumor heterogeneity has been compared with Darwinian evolution and survival of the fittest. The evolutionary ecosystem of tumors consisting of heterogeneous tumor cell populations represents a considerable challenge to tumor therapy, since all genetically and phenotypically different subpopulations have to be efficiently killed by therapy. Otherwise, even small surviving subpopulations may cause repopulation and refractory tumors. Single-cell sequencing allows for a better understanding of the genomic principles of tumor heterogeneity and represents the basis for more successful tumor treatments. The isolation and sequencing of single tumor cells still represents a considerable technical challenge and consists of three major steps: (1) single cell isolation (e.g., by laser-capture microdissection), fluorescence-activated cell sorting, micromanipulation, whole genome amplification (e.g., with the help of Phi29 DNA polymerase), and transcriptome-wide next generation sequencing technologies (e.g., 454 pyrosequencing, Illumina sequencing, and other systems). Data demonstrating the feasibility of single-cell sequencing for monitoring the emergence of drug-resistant cell clones in patient samples are discussed herein. It is envisioned that single-cell sequencing will be a valuable asset to assist the design of regimens for personalized tumor therapies based on tumor subpopulation-specific genetic alterations in individual patients.
Sampling through time and phylodynamic inference with coalescent and birth–death models
Volz, Erik M.; Frost, Simon D. W.
2014-01-01
Many population genetic models have been developed for the purpose of inferring population size and growth rates from random samples of genetic data. We examine two popular approaches to this problem, the coalescent and the birth–death-sampling model (BDM), in the context of estimating population size and birth rates in a population growing exponentially according to the birth–death branching process. For sequences sampled at a single time, we found the coalescent and the BDM gave virtually indistinguishable results in terms of the growth rates and fraction of the population sampled, even when sampling from a small population. For sequences sampled at multiple time points, we find that the birth–death model estimators are subject to large bias if the sampling process is misspecified. Since BDMs incorporate a model of the sampling process, we show how much of the statistical power of BDMs arises from the sequence of sample times and not from the genealogical tree. This motivates the development of a new coalescent estimator, which is augmented with a model of the known sampling process and is potentially more precise than the coalescent that does not use sample time information. PMID:25401173
Sensitive Spin Detection Using An On-Chip Squid-Waveguide Resonator
NASA Astrophysics Data System (ADS)
Yue, Guang
Quantum computing gives novel way of computing using quantum mechanics, which furthers human knowledge and has exciting applications. Quantum systems with diluted spins such as rare earth ions hosted in single crystal, molecule-based magnets etc. are promising qubits candidates to form the basis of a quantum computer. High sensitivity measurement and coherent control of these spin systems are crucial for their practical usage as qubits. The micro-SQUID (direct-current micrometer-sized Superconducting QUantum Interference Device) is capable to measure magnetization of spin system with high sensitivity. For example, the micro-SQUID technique can measure magnetic moments as small as several thousand muB as shown by the study of [W. Wernsdorfer, Supercond. Sci. Technol. 22, 064013 (2009)]. Here we develop a novel on-chip setup that combines the micro-SQUID sensitivity with microwave excitation. Such setup can be used for electron spin resonance measurements or coherent control of spins utilizing the high sensitivity of micro-SQUID for signal detection. To build the setup, we studied the fabrication process of the micro-SQUID, which is made of weak-linked Josephson junctions. The SQUID as a detector is integrated on the same chip with a shorted coplanar waveguide, so that the microwave pulses can be applied through the waveguide to excite the sample for resonance measurements. The whole device is plasma etched from a thin (˜ 20nm) niobium film, so that the SQUID can work at in large in-plane magnetic fields of several tesla. In addition, computer simulations are done to find the best design of the waveguide such that the microwave excitation field is sufficiently strong and uniformly applied to the sample. The magnetization curve of Mn12 molecule-based magnet sample is measured to prove the proper working of the micro-SQUID. Electron spin resonance measurement is done on the setup for gadolinium ions diluted in a CaWO4 single crystal. The measurement shows clear evidence of the resonance signal from the 1st transition of the gadolinium ions' energy levels, which shows the setup is successfully built. Due to the high sensitivity of micro-SQUID and the ability to concentrate microwave energy in small areas of the chip, this setup can detect signals from a small number of spins (107) in a small volume (several mum 3).
Actualizing Flexible National Security Space Systems
2011-01-01
single launch vehicle is a decision unique to small satellites that adds an extra dimension to the launch risk calculation. While bundling...following a launch failure. The ability to bundle multiple payloads on a single launch vehicle is a decision unique to small satellites that adds an extra ... dimension to the launch risk calculation. While bundling multiple small satellites on a single launch vehicle spreads the initial launch cost across
A Single IGF1 Allele Is a Major Determinant of Small Size in Dogs
Sutter, Nathan B.; Bustamante, Carlos D.; Chase, Kevin; Gray, Melissa M.; Zhao, Keyan; Zhu, Lan; Padhukasahasram, Badri; Karlins, Eric; Davis, Sean; Jones, Paul G.; Quignon, Pascale; Johnson, Gary S.; Parker, Heidi G.; Fretwell, Neale; Mosher, Dana S.; Lawler, Dennis F.; Satyaraj, Ebenezer; Nordborg, Magnus; Lark, K. Gordon; Wayne, Robert K.; Ostrander, Elaine A.
2009-01-01
The domestic dog exhibits greater diversity in body size than any other terrestrial vertebrate. We used a strategy that exploits the breed structure of dogs to investigate the genetic basis of size. First, through a genome-wide scan, we identified a major quantitative trait locus (QTL) on chromosome 15 influencing size variation within a single breed. Second, we examined genetic variation in the 15-megabase interval surrounding the QTL in small and giant breeds and found marked evidence for a selective sweep spanning a single gene (IGF1), encoding insulin-like growth factor 1. A single IGF1 single-nucleotide polymorphism haplotype is common to all small breeds and nearly absent from giant breeds, suggesting that the same causal sequence variant is a major contributor to body size in all small dogs. PMID:17412960
A single IGF1 allele is a major determinant of small size in dogs.
Sutter, Nathan B; Bustamante, Carlos D; Chase, Kevin; Gray, Melissa M; Zhao, Keyan; Zhu, Lan; Padhukasahasram, Badri; Karlins, Eric; Davis, Sean; Jones, Paul G; Quignon, Pascale; Johnson, Gary S; Parker, Heidi G; Fretwell, Neale; Mosher, Dana S; Lawler, Dennis F; Satyaraj, Ebenezer; Nordborg, Magnus; Lark, K Gordon; Wayne, Robert K; Ostrander, Elaine A
2007-04-06
The domestic dog exhibits greater diversity in body size than any other terrestrial vertebrate. We used a strategy that exploits the breed structure of dogs to investigate the genetic basis of size. First, through a genome-wide scan, we identified a major quantitative trait locus (QTL) on chromosome 15 influencing size variation within a single breed. Second, we examined genetic variation in the 15-megabase interval surrounding the QTL in small and giant breeds and found marked evidence for a selective sweep spanning a single gene (IGF1), encoding insulin-like growth factor 1. A single IGF1 single-nucleotide polymorphism haplotype is common to all small breeds and nearly absent from giant breeds, suggesting that the same causal sequence variant is a major contributor to body size in all small dogs.
Zhu, Ying; Zhao, Rui; Piehowski, Paul D.; ...
2017-09-01
One of the greatest challenges for mass spectrometry (MS)-based proteomics is the limited ability to analyze small samples. Here in this study, we investigate the relative contributions of liquid chromatography (LC), MS instrumentation and data analysis methods with the aim of improving proteome coverage for sample sizes ranging from 0.5 ng to 50 ng. We show that the LC separations utilizing 30-μm-i.d. columns increase signal intensity by >3-fold relative to those using 75-μm-i.d. columns, leading to 32% increase in peptide identifications. The Orbitrap Fusion Lumos MS significantly boosted both sensitivity and sequencing speed relative to earlier generation Orbitraps (e.g., LTQ-Orbitrap),more » leading to a ~3-fold increase in peptide identifications and 1.7-fold increase in identified protein groups for 2 ng tryptic digests of the bacterium S. oneidensis. The Match Between Runs algorithm of open-source MaxQuant software further increased proteome coverage by ~95% for 0.5 ng samples and by ~42% for 2 ng samples. Using the best combination of the above variables, we were able to identify >3,000 proteins from 10 ng tryptic digests from both HeLa and THP-1 mammalian cell lines. We also identified >950 proteins from subnanogram archaeal/bacterial cocultures. Finally, the present ultrasensitive LC-MS platform achieves a level of proteome coverage not previously realized for ultra-small sample loadings, and is expected to facilitate the analysis of subnanogram samples, including single mammalian cells.« less
De Jong, G D; Hoback, W W
2006-06-01
Carrion insect succession studies have historically used repeated sampling of single or a few carcasses to produce data, either weighing the carcasses, removing a qualitative subsample of the fauna present, or both, on every visit over the course of decomposition and succession. This study, conducted in a set of related experimental hypotheses with two trials in a single season, investigated the effect that repeated sampling has on insect succession, determined by the number of taxa collected on each visit and by community composition. Each trial lasted at least 21 days, with daily visits on the first 14 days. Rat carcasses used in this study were all placed in the field on the same day, but then either sampled qualitatively on every visit (similar to most succession studies) or ignored until a given day of succession, when they were sampled qualitatively (a subsample) and then destructively sampled in their entirety. Carcasses sampled on every visit were in two groups: those from which only a sample of the fauna was taken and those from which a sample of fauna was taken and the carcass was weighed for biomass determination. Of the carcasses visited only once, the number of taxa in subsamples was compared to the actual number of taxa present when the carcass was destructively sampled to determine if the subsamples adequately represented the total carcass fauna. Data from the qualitative subsamples of those carcasses visited only once were also compared to data collected from carcasses that were sampled on every visit to investigate the effect of the repeated sampling. A total of 39 taxa were collected from carcasses during the study and the component taxa are discussed individually in relation to their role in succession. Number of taxa differed on only one visit between the qualitative subsamples and the actual number of taxa present, primarily because the organisms missed by the qualitative sampling were cryptic (hidden deep within body cavities) or rare (only represented by very few specimens). There were no differences discovered between number of taxa in qualitative subsamples from carcasses sampled repeatedly (with or without biomass determinations) and those sampled only a single time. Community composition differed considerably in later stages of decomposition, with disparate communities due primarily to small numbers of rare taxa. These results indicate that the methods used historically for community composition determination in experimental forensic entomology are generally adequate.
Shankar, Vijay; Reo, Nicholas V; Paliy, Oleg
2015-12-09
We previously showed that stool samples of pre-adolescent and adolescent US children diagnosed with diarrhea-predominant IBS (IBS-D) had different compositions of microbiota and metabolites compared to healthy age-matched controls. Here we explored whether observed fecal microbiota and metabolite differences between these two adolescent populations can be used to discriminate between IBS and health. We constructed individual microbiota- and metabolite-based sample classification models based on the partial least squares multivariate analysis and then applied a Bayesian approach to integrate individual models into a single classifier. The resulting combined classification achieved 84 % accuracy of correct sample group assignment and 86 % prediction for IBS-D in cross-validation tests. The performance of the cumulative classification model was further validated by the de novo analysis of stool samples from a small independent IBS-D cohort. High-throughput microbial and metabolite profiling of subject stool samples can be used to facilitate IBS diagnosis.
Calculating p-values and their significances with the Energy Test for large datasets
NASA Astrophysics Data System (ADS)
Barter, W.; Burr, C.; Parkes, C.
2018-04-01
The energy test method is a multi-dimensional test of whether two samples are consistent with arising from the same underlying population, through the calculation of a single test statistic (called the T-value). The method has recently been used in particle physics to search for samples that differ due to CP violation. The generalised extreme value function has previously been used to describe the distribution of T-values under the null hypothesis that the two samples are drawn from the same underlying population. We show that, in a simple test case, the distribution is not sufficiently well described by the generalised extreme value function. We present a new method, where the distribution of T-values under the null hypothesis when comparing two large samples can be found by scaling the distribution found when comparing small samples drawn from the same population. This method can then be used to quickly calculate the p-values associated with the results of the test.
Northwest Africa 8535 and Northwest Africa 10463: New Insights into the Angrite Parent Body
NASA Technical Reports Server (NTRS)
Santos, A. R.; Agee, C. B.; Shearer, C. K.; McCubbin, F. M.
2016-01-01
The angrite meteorites are valuable samples of igneous rocks formed early in Solar System history (approx.4.56 Ga, summarized in [1]). This small meteorite group (approx.24 individually named specimens) consists of rocks with somewhat exotic mineral compositions (e.g., high Ca olivine, Al-Ti-bearing diopside-hedenbergite, calcium silico-phosphates), resulting in exotic bulk rock compositions. These mineral assemblages remain fairly consistent among angrite samples, which suggests they formed due to similar processes from a single mantle source. There is still debate over the formation process for these rocks (see summary in [1]), and analysis of additional angrite samples may help to address this debate. Toward this end, we have begun to study two new angrites, Northwest Africa 8535, a dunite, and Northwest Africa 10463, a basaltic angrite.
SRD5A1 genotype frequency differences in women with mild versus severe premenstrual symptoms.
Adams, Marlene; McCrone, Susan
2012-02-01
The aims of this small pilot study were to explore the association between premenstrual symptom severity and two genes from the gamma-aminobutyric acid (GABA) pathway: steroid-5-alpha-reductase, alpha polypeptide 1 (SRD5A1) and gamma-aminobutyric acid receptor subunit alpha-4 (GABRA4). Saliva samples were obtained from a convenience sample of 19 Caucasian females ages 18-25 years, ten cases and nine controls. Deoxyribonucleic acid (DNA) was isolated, and genotyping performed on ten single nucleotide polymorphisms (SNPs). Ten percent of cases and 44% of controls had the cytosine/cytosine (C/C) genotype for the SRD5A1 SNP, rs501999 indicating that this genotype may protect women against severe premenstrual symptoms. Replication of this study using an adequately powered sample size is warranted.
Cappione, Amedeo; Mabuchi, Masaharu; Briggs, David; Nadler, Timothy
2015-04-01
Protein immuno-detection encompasses a broad range of analytical methodologies, including western blotting, flow cytometry, and microscope-based applications. These assays which detect, quantify, and/or localize expression for one or more proteins in complex biological samples, are reliant upon fluorescent or enzyme-tagged target-specific antibodies. While small molecule labeling kits are available with a range of detection moieties, the workflow is hampered by a requirement for multiple dialysis-based buffer exchange steps that are both time-consuming and subject to sample loss. In a previous study, we briefly described an alternative method for small-scale protein labeling with small molecule dyes whereby all phases of the conjugation workflow could be performed in a single centrifugal diafiltration device. Here, we expand on this foundational work addressing functionality of the device at each step in the workflow (sample cleanup, labeling, unbound dye removal, and buffer exchange/concentration) and the implications for optimizing labeling efficiency. When compared to other common buffer exchange methodologies, centrifugal diafiltration offered superior performance as measured by four key parameters (process time, desalting capacity, protein recovery, retain functional integrity). Originally designed for resin-based affinity purification, the device also provides a platform for up-front antibody purification or albumin carrier removal. Most significantly, by exploiting the rapid kinetics of NHS-based labeling reactions, the process of continuous diafiltration minimizes reaction time and long exposure to excess dye, guaranteeing maximal target labeling while limiting the risks associated with over-labeling. Overall, the device offers a simplified workflow with reduced processing time and hands-on requirements, without sacrificing labeling efficiency, final yield, or conjugate performance. Copyright © 2015 Elsevier B.V. All rights reserved.
Grass height and transmission ecology of Echinococcus multilocularis in Tibetan communities, China.
Wang, Qian; Raoul, Francis; Budke, Christine; Craig, Philip S; Xiao, Yong-fu; Vuitton, Dominique A; Campos-Ponce, Maiza; Qiu, Dong-chuan; Pleydell, David; Giraudoux, Patrick
2010-01-05
Alveolar echinococcosis is a major zoonosis of public health significance in western China. Overgrazing was recently assumed as a potential risk factor for transmission of alveolar echinococcosis. The research was designed to further test the overgrazing hypothesis by investigating how overgrazing influenced the burrow density of intermediate host small mammals and how the burrow density of small mammals was associated with dog Echinococcus multilocularis infection. The study sites were chosen by previous studies which found areas where the alveolar echinococcosis was prevalent. The data, including grass height, burrow density of intermediate host small mammals, dog and fox fecal samples as well as Global Positioning System (GPS) position, were collected from field investigations in Shiqu County, Sichuan Province, China. The fecal samples were analyzed using copro-PCR. The worms, teeth, bones and hairs in the fecal samples were visually examined. Single factor and multifactor analyses tools including chi square and generalized linear models were applied to these data. By using grass height as a proxy of grazing pressure in the homogenous pasture, this study found that taller grass in the pasture led to lower small mammals' burrow density (chi(2) = 4.670, P = 0.031, coefficient = -1.570). The Echinococcus multilocularis worm burden in dogs was statistically significantly related to the maximum density of the intermediate host Ochotona spp. (chi(2) = 5.250, P = 0.022, coefficient = 0.028). The prevalence in owned dogs was positively correlated to the number of stray dogs seen within a 200 meter radius (Wald chi(2) = 8.375, P = 0.004, odds ratio = 1.198). Our findings support the hypothesis that overgrazing promotes transmission of alveolar echinococcosis and confirm the role of stray dogs in the transmission of alveolar echinococcosis.
Sidler, Dominik; Schwaninger, Arthur; Riniker, Sereina
2016-10-21
In molecular dynamics (MD) simulations, free-energy differences are often calculated using free energy perturbation or thermodynamic integration (TI) methods. However, both techniques are only suited to calculate free-energy differences between two end states. Enveloping distribution sampling (EDS) presents an attractive alternative that allows to calculate multiple free-energy differences in a single simulation. In EDS, a reference state is simulated which "envelopes" the end states. The challenge of this methodology is the determination of optimal reference-state parameters to ensure equal sampling of all end states. Currently, the automatic determination of the reference-state parameters for multiple end states is an unsolved issue that limits the application of the methodology. To resolve this, we have generalised the replica-exchange EDS (RE-EDS) approach, introduced by Lee et al. [J. Chem. Theory Comput. 10, 2738 (2014)] for constant-pH MD simulations. By exchanging configurations between replicas with different reference-state parameters, the complexity of the parameter-choice problem can be substantially reduced. A new robust scheme to estimate the reference-state parameters from a short initial RE-EDS simulation with default parameters was developed, which allowed the calculation of 36 free-energy differences between nine small-molecule inhibitors of phenylethanolamine N-methyltransferase from a single simulation. The resulting free-energy differences were in excellent agreement with values obtained previously by TI and two-state EDS simulations.
Simple sampling strategy for measuring inulin renal clearance.
Horio, Masaru; Imai, Enyu; Yasuda, Yoshinari; Hishida, Akira; Matsuo, Seiichi
2009-02-01
In the standard method of inulin clearance (Cin), three sets of serum and urine samples are collected during a 2-hour clearance period. For a practical use of this method, sampling should be the minimal number allowable while still providing enough accuracy. The aim of this study was to evaluate the validity of inulin renal clearance with assumed single urine collection with a period such as 30, 60 or 90 minutes. Inulin clearance data collected by the standard method from 737 individuals were used. Changes of serum inulin concentrations between 45 and 105 minutes after the start of the infusion were analyzed. We used first urine collection to calculate the inulin clearance with single urine collection (Cin-30 min). We assumed single urine collection for 60 or 90 minutes by combining the urine data of the consecutive 30-minute periods. Inulin clearances (Cin-60 min, Cin-90 min) were calculated from the assumed single urine collections, respectively. Serum inulin concentration did not reach equilibrium during the clearance period. It increased in subjects with low glomerular filtration rate (GFR) and decreased in subjects with normal GFR. The amount of the change was small and -0.5 +/- 12.6% in subjects with GFR over 30 ml/min per 1.73 m(2). Cin-30 min, Cin-60 min and Cin-90 min showed high correlation coefficients against Cin-ST (0.962, 0.988 and 0.998, respectively). Systemic biases in these clearances were negligible (under 1 ml/min per 1.73 m(2)). Root mean square error (RMSE) were 10.4, 5.3 and 2.3 ml/min per 1.73 m(2) for Cin-30 min, Cin-60 min and Cin-90 min, respectively. These data indicated that accuracy of inulin clearance depends on the duration of the urine collection period. Inulin clearance with a single urine collection is a convenient method. We showed that single urine collection for 30 minutes or a longer period has reasonable accuracy in calculation of inulin clearance. We propose a method of inulin clearance with single urine collection for 60 minutes.
Characterization of Human Salivary Extracellular RNA by Next-generation Sequencing.
Li, Feng; Kaczor-Urbanowicz, Karolina Elżbieta; Sun, Jie; Majem, Blanca; Lo, Hsien-Chun; Kim, Yong; Koyano, Kikuye; Liu Rao, Shannon; Young Kang, So; Mi Kim, Su; Kim, Kyoung-Mee; Kim, Sung; Chia, David; Elashoff, David; Grogan, Tristan R; Xiao, Xinshu; Wong, David T W
2018-04-23
It was recently discovered that abundant and stable extracellular RNA (exRNA) species exist in bodily fluids. Saliva is an emerging biofluid for biomarker development for noninvasive detection and screening of local and systemic diseases. Use of RNA-Sequencing (RNA-Seq) to profile exRNA is rapidly growing; however, no single preparation and analysis protocol can be used for all biofluids. Specifically, RNA-Seq of saliva is particularly challenging owing to high abundance of bacterial contents and low abundance of salivary exRNA. Given the laborious procedures needed for RNA-Seq library construction, sequencing, data storage, and data analysis, saliva-specific and optimized protocols are essential. We compared different RNA isolation methods and library construction kits for long and small RNA sequencing. The role of ribosomal RNA (rRNA) depletion also was evaluated. The miRNeasy Micro Kit (Qiagen) showed the highest total RNA yield (70.8 ng/mL cell-free saliva) and best small RNA recovery, and the NEBNext library preparation kits resulted in the highest number of detected human genes [5649-6813 at 1 reads per kilobase RNA per million mapped (RPKM)] and small RNAs [482-696 microRNAs (miRNAs) and 190-214 other small RNAs]. The proportion of human RNA-Seq reads was much higher in rRNA-depleted saliva samples (41%) than in samples without rRNA depletion (14%). In addition, the transfer RNA (tRNA)-derived RNA fragments (tRFs), a novel class of small RNAs, were highly abundant in human saliva, specifically tRF-4 (4%) and tRF-5 (15.25%). Our results may help in selection of the best adapted methods of RNA isolation and small and long RNA library constructions for salivary exRNA studies. © 2018 American Association for Clinical Chemistry.
The economic impact of peste des petits ruminants in India.
Bardhan, D; Kumar, S; Anandsekaran, G; Chaudhury, J K; Meraj, M; Singh, R K; Verma, M R; Kumar, D; Kumar P T, N; Ahmed Lone, S; Mishra, V; Mohanty, B S; Korade, N; De, U K
2017-04-01
Peste des petits ruminants (PPR) is an economically important livestock disease which affects a vast section of the small ruminant population in India. However, data on the incidence of PPR are limited and scant literature is available on the economic losses caused by the disease. In the present study, a structured sampling design was adopted, which covered the major agro-climatic regions of the country, to ascertain the morbidity and mortality rates of PPR. Available estimates of the economic losses in India due to various livestock diseases are based on single values of various epidemiological and economic parameters. Stochastic modelling was used to estimate the economic impact of PPR. Overall annual morbidity and mortality rates of PPR for small ruminants in India have been estimated from the sample as being 8%and 3.45%, respectively. The authors have analysed variations in these rates across species, age group, sex, season and region. The expected annual economic loss due to PPR in India ranges from as little as US $2 million to $18 million and may go up to US $1.5 billion; the most likely range of expected economic losses is between US $653 million and $669 million. This study thus reveals significant losses due to the incidence of PPR in small ruminants in India.
A machine for haemodialysing very small infants.
Everdell, Nicholas L; Coulthard, Malcolm G; Crosier, Jean; Keir, Michael J
2005-05-01
Babies weighing under 6 kg are difficult to dialyse, especially those as small as 1 kg. Peritoneal dialysis is easier than haemodialysis, but is not always possible, and clears molecules less efficiently. Two factors complicate haemodialysis. First, extracorporeal circuits are large relative to a baby's blood volume, necessitating priming with fresh or modified blood. Second, blood flow from infants' access vessels is disproportionately low (Poiseuille's law), causing inadequate dialysis, or clotting within the circuit. These problems are minimised by using single lumen access, a very small circuit, and a reservoir syringe to separate the sampling and dialyser blood flow rates. Its manual operation is tedious, so we developed a computer-controlled, pressure-monitored machine to run it, including adjusting the blood withdrawal rate from poorly sampling lines. We have dialysed four babies weighing 0.8-3.4 kg, with renal failure or metabolic disorders. The circuits did not require priming. Clearances of creatinine, urea, potassium, phosphate and ammonia were mean (SD) 0.54 (0.22) ml/min using one dialyser, and 0.98 (0.22) ml/min using two in parallel. Ammonia clearance in a 2.4 kg baby had a 9 h half-life. Ultrafiltration up to 45 ml/h was achieved easily. This device provided infants with immediate, effective and convenient haemodialysis, typically delivered for prolonged periods.
NASA Astrophysics Data System (ADS)
Kovalenko, I. D.; Doressoundiram, A.; Lellouch, E.; Vilenius, E.; Müller, T.; Stansberry, J.
2017-11-01
Context. Gravitationally bound multiple systems provide an opportunity to estimate the mean bulk density of the objects, whereas this characteristic is not available for single objects. Being a primitive population of the outer solar system, binary and multiple trans-Neptunian objects (TNOs) provide unique information about bulk density and internal structure, improving our understanding of their formation and evolution. Aims: The goal of this work is to analyse parameters of multiple trans-Neptunian systems, observed with Herschel and Spitzer space telescopes. Particularly, statistical analysis is done for radiometric size and geometric albedo, obtained from photometric observations, and for estimated bulk density. Methods: We use Monte Carlo simulation to estimate the real size distribution of TNOs. For this purpose, we expand the dataset of diameters by adopting the Minor Planet Center database list with available values of the absolute magnitude therein, and the albedo distribution derived from Herschel radiometric measurements. We use the 2-sample Anderson-Darling non-parametric statistical method for testing whether two samples of diameters, for binary and single TNOs, come from the same distribution. Additionally, we use the Spearman's coefficient as a measure of rank correlations between parameters. Uncertainties of estimated parameters together with lack of data are taken into account. Conclusions about correlations between parameters are based on statistical hypothesis testing. Results: We have found that the difference in size distributions of multiple and single TNOs is biased by small objects. The test on correlations between parameters shows that the effective diameter of binary TNOs strongly correlates with heliocentric orbital inclination and with magnitude difference between components of binary system. The correlation between diameter and magnitude difference implies that small and large binaries are formed by different mechanisms. Furthermore, the statistical test indicates, although not significant with the sample size, that a moderately strong correlation exists between diameter and bulk density. Herschel is an ESA space observatory with science instruments provided by European-led Principal Investigator consortia and with important participation from NASA.
Shock and Microstructural Characterization of the α-ω Phase Transition in Titanium Crystals
NASA Astrophysics Data System (ADS)
Morrow, Benjamin M.; Rigg, Paulo A.; Jones, David R.; Addessio, Francis L.; Trujillo, Carl P.; Saavedra, Ramon A.; Martinez, Daniel T.; Cerreta, Ellen K.
2017-12-01
A multicrystal comprised of a small number of large crystals of high-purity titanium and a [0001] oriented high-purity single crystal titanium sample were shock loaded using gas gun plate impact experiments. Tests were performed at stresses above the α {-}ω phase transition stress (for high-purity polycrystalline specimens) to observe the behavior of oriented crystals under similar conditions. Post-mortem characterization of the shocked microstructure was conducted on the single crystal sample to measure textures, and quantify phases and twinning. The apparent activation of plastic and transformation mechanisms was dependent upon crystal orientation. Specifically, the [0001] crystal showed a higher Hugoniot elastic limit than the [10\\bar{1}0] or [3\\bar{1}\\bar{4}4] orientations. The slope of velocity as a function of time was lower in the [0001] orientation than the other orientations during plastic deformation, indicating sluggish transformation kinetics for the α to ω phase transition for the [0001] oriented crystal. Microtexture measurements of a recovered [0001] oriented single crystal revealed the presence of retained ω phase after unloading, with orientations of the constituent phase fractions indicative of the forward α → ω transition, rather than the reverse ω → α transition, suggesting that the material never achieved a state of 100% ω phase.
Grey matter networks in people at increased familial risk for schizophrenia.
Tijms, Betty M; Sprooten, Emma; Job, Dominic; Johnstone, Eve C; Owens, David G C; Willshaw, David; Seriès, Peggy; Lawrie, Stephen M
2015-10-01
Grey matter brain networks are disrupted in schizophrenia, but it is still unclear at which point during the development of the illness these disruptions arise and whether these can be associated with behavioural predictors of schizophrenia. We investigated if single-subject grey matter networks were disrupted in a sample of people at familial risk of schizophrenia. Single-subject grey matter networks were extracted from structural MRI scans of 144 high risk subjects, 32 recent-onset patients and 36 healthy controls. The following network properties were calculated: size, connectivity density, degree, path length, clustering coefficient, betweenness centrality and small world properties. People at risk of schizophrenia showed decreased path length and clustering in mostly prefrontal and temporal areas. Within the high risk sample, the path length of the posterior cingulate cortex and the betweenness centrality of the left inferior frontal operculum explained 81% of the variance in schizotypal cognitions, which was previously shown to be the strongest behavioural predictor of schizophrenia in the study. In contrast, local grey matter volume measurements explained 48% of variance in schizotypy. The present results suggest that single-subject grey matter networks can quantify behaviourally relevant biological alterations in people at increased risk for schizophrenia before disease onset. Copyright © 2015 Elsevier B.V. All rights reserved.
Sirugudu, Roopas Kiran; Vemuri, Rama Krishna Murthy; Venkatachalam, Subramanian; Gopalakrishnan, Anisha; Budaraju, Srinivasa Murty
2011-01-01
Microwave sintering of materials significantly depends on dielectric, magnetic and conductive Losses. Samples with high dielectric and magnetic loss such as ferrites could be sintered easily. But low dielectric loss material such as dielectric resonators (paraelectrics) finds difficulty in generation of heat during microwave interaction. Microwave sintering of materials of these two classes helps in understanding the variation in dielectric and magnetic characteristics with respect to the change in grain size. High-energy ball milled Ni0.6Cu0.2Zn0.2Fe1.98O4-delta and ZnTiO3 are sintered in conventional and microwave methods and characterized for respective dielectric and magnetic characteristics. The grain size variation with higher copper content is also observed with conventional and microwave sintering. The grain size in microwave sintered Ni0.6Cu0.2Zn0.2Fe1.98O4-delta is found to be much small and uniform in comparison with conventional sintered sample. However, the grain size of microwave sintered sample is almost equal to that of conventional sintered sample of Ni0.3Cu0.5Zn0.2Fe1.98O4-delta. In contrast to these high dielectric and magnetic loss ferrites, the paraelectric materials are observed to sinter in presence of microwaves. Although microwave sintered zinc titanate sample showed finer and uniform grains with respect to conventional samples, the dielectric characteristics of microwave sintered sample are found to be less than that of conventional sample. Low dielectric constant is attributed to the low density. Smaller grain size is found to be responsible for low quality factor and the presence of small percentage of TiO2 is observed to achieve the temperature stable resonant frequency.
Telecom wavelength single quantum dots with very small excitonic fine-structure splitting
NASA Astrophysics Data System (ADS)
Kors, Andrei; Reithmaier, Johann Peter; Benyoucef, Mohamed
2018-04-01
We report on molecular beam epitaxy growth of symmetric InAs/InP quantum dots (QDs) emitting at a telecom C-band (1.55 μm) with an ultra-small excitonic fine-structure splitting of ˜2 μeV. The QDs are grown on a distributed Bragg reflector (DBR) and systematically characterized by micro-photoluminescence (μ-PL) measurements. One order of magnitude of QD PL intensity enhancement is observed in comparison to the samples without DBR. A combination of power-dependent and polarization-resolved measurements reveals background-free exciton, biexciton, and dark exciton emission with a resolution-limited linewidth below 35 μeV and a biexciton binding energy of ˜1 meV. The results are confirmed by statistical measurements of about 20 QDs.
Rames, Matthew; Yu, Yadong; Ren, Gang
2014-08-15
Structural determination of proteins is rather challenging for proteins with molecular masses between 40 - 200 kDa. Considering that more than half of natural proteins have a molecular mass between 40 - 200 kDa, a robust and high-throughput method with a nanometer resolution capability is needed. Negative staining (NS) electron microscopy (EM) is an easy, rapid, and qualitative approach which has frequently been used in research laboratories to examine protein structure and protein-protein interactions. Unfortunately, conventional NS protocols often generate structural artifacts on proteins, especially with lipoproteins that usually form presenting rouleaux artifacts. By using images of lipoproteins from cryo-electronmore » microscopy (cryo-EM) as a standard, the key parameters in NS specimen preparation conditions were recently screened and reported as the optimized NS protocol (OpNS), a modified conventional NS protocol. Artifacts like rouleaux can be greatly limited by OpNS, additionally providing high contrast along with reasonably high-resolution (near 1 nm) images of small and asymmetric proteins. These high-resolution and high contrast images are even favorable for an individual protein (a single object, no average) 3D reconstruction, such as a 160 kDa antibody, through the method of electron tomography. Moreover, OpNS can be a high-throughput tool to examine hundreds of samples of small proteins. For example, the previously published mechanism of 53 kDa cholesteryl ester transfer protein (CETP) involved the screening and imaging of hundreds of samples. Considering cryo-EM rarely successfully images proteins less than 200 kDa has yet to publish any study involving screening over one hundred sample conditions, it is fair to call OpNS a high-throughput method for studying small proteins. Hopefully the OpNS protocol presented here can be a useful tool to push the boundaries of EM and accelerate EM studies into small protein structure, dynamics and mechanisms.« less
Circumnuclear Regions In Barred Spiral Galaxies. 1; Near-Infrared Imaging
NASA Technical Reports Server (NTRS)
Perez-Ramirez, D.; Knapen, J. H.; Peletier, R. F.; Laine, S.; Doyon, R.; Nadeau, D.
2000-01-01
We present sub-arcsecond resolution ground-based near-infrared images of the central regions of a sample of twelve barred galaxies with circumnuclear star formation activity, which is organized in ring-like regions typically one kiloparsec in diameter. We also present Hubble Space Telescope near-infrared images of ten of our sample galaxies, and compare them with our ground-based data. Although our sample galaxies were selected for the presence of circumnuclear star formation activity, our broad-band near-infrared images are heterogeneous, showing a substantial amount of small-scale structure in some galaxies, and practically none in others. We argue that, where it exists, this structure is caused by young stars, which also cause the characteristic bumps or changes in slope in the radial profiles of ellipticity, major axis position angle, surface brightness and colour at the radius of the circumnuclear ring in most of our sample galaxies. In 7 out of 10 HST images, star formation in the nuclear ring is clearly visible as a large number of small emitting regions, organised into spiral arm fragments, which are accompanied by dust lanes. NIR colour index maps show much more clearly the location of dust lanes and, in certain cases, regions of star formation than single broad-band images. Circumnuclear spiral structure thus outlined appears to be common in barred spiral galaxies with circumnuclear star formation.
NASA Astrophysics Data System (ADS)
Rotem, Asaf; Garraway, Levi; Su, Mei-Ju; Basu, Anindita; Regev, Aviv; Struhl, Kevin
2017-02-01
Three-dimensional growth conditions reflect the natural environment of cancer cells and are crucial to be performed at drug screens. We developed a 3D assay for cellular transformation that involves growth in low attachment (GILA) conditions and is strongly correlated with the 50-year old benchmark assay-soft agar. Using GILA, we performed high-throughput screens for drugs and genes that selectively inhibit or increase transformation, but not proliferation. This phenotypic approach is complementary to our genetic approach that utilizes single-cell RNA-sequencing of a patient sample to identify putative oncogenes that confer sensitivity to drugs designed to specifically inhibit the identified oncoprotein. Currently, we are dealing with a big challenge in our field- the limited number of cells that might be extracted from a biopsy. Small patient-derived samples are hard to test in the traditional multiwell plate and it will be helpful to minimize the culture area and the experimental system. We managed to design a suitable microfluidic device for limited number of cells and perform the assay using image analysis. We aim to test drugs on tumor cells, outside of the patient body- and recommend on the ideal treatment that is tailored to the individual. This device will help to minimize biopsy-sampling volumes and minimize interventions in the patient's tumor.
Kim, Eun Hye; Lee, Hwan Young; Yang, In Seok; Jung, Sang-Eun; Yang, Woo Ick; Shin, Kyoung-Jin
2016-05-01
The next-generation sequencing (NGS) method has been utilized to analyze short tandem repeat (STR) markers, which are routinely used for human identification purposes in the forensic field. Some researchers have demonstrated the successful application of the NGS system to STR typing, suggesting that NGS technology may be an alternative or additional method to overcome limitations of capillary electrophoresis (CE)-based STR profiling. However, there has been no available multiplex PCR system that is optimized for NGS analysis of forensic STR markers. Thus, we constructed a multiplex PCR system for the NGS analysis of 18 markers (13CODIS STRs, D2S1338, D19S433, Penta D, Penta E and amelogenin) by designing amplicons in the size range of 77-210 base pairs. Then, PCR products were generated from two single-sources, mixed samples and artificially degraded DNA samples using a multiplex PCR system, and were prepared for sequencing on the MiSeq system through construction of a subsequent barcoded library. By performing NGS and analyzing the data, we confirmed that the resultant STR genotypes were consistent with those of CE-based typing. Moreover, sequence variations were detected in targeted STR regions. Through the use of small-sized amplicons, the developed multiplex PCR system enables researchers to obtain successful STR profiles even from artificially degraded DNA as well as STR loci which are analyzed with large-sized amplicons in the CE-based commercial kits. In addition, successful profiles can be obtained from mixtures up to a 1:19 ratio. Consequently, the developed multiplex PCR system, which produces small size amplicons, can be successfully applied to STR NGS analysis of forensic casework samples such as mixtures and degraded DNA samples. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Intrepid: Exploring the NEA population with a Fleet of Highly Autonomous SmallSat explorers
NASA Astrophysics Data System (ADS)
Blacksberg, Jordana; Chesley, Steven R.; Ehlmann, Bethany; Raymond, Carol Anne
2017-10-01
The Intrepid mission concept calls for phased deployment of a fleet of small highly autonomous rendezvous spacecraft designed to characterize the evolution, structure and composition of dozens of Near-Earth Asteroids (NEAs). Intrepid represents a marked departure from conventional solar system exploration projects, where a single unique and complex spacecraft is typically directed to explore a single target body. In contrast, Intrepid relies on the deployment of a large number of autonomous spacecraft to provide redundancy and ensure that the project goals are achieved at a small fraction of the cost of typical missions.The Intrepid science goals are threefold: (1) to understand the evolutionary processes that govern asteroid physical, chemical and dynamical histories and relate these results to solar system origins and evolution; (2) to facilitate impactor deflection scenarios for planetary defense by statistically characterizing relevant asteroid physical properties; (3) to quantify the presence and extractability of potentially useful resources on a large sample of asteroids. To achieve these goals, the baseline architecture includes multiple modular instruments including cameras, spectrometers, radar sounders, and projectiles that could interact with the target asteroid. Key questions to be addressed are: what is the total quantity of water in each object? How is the water incorporated? Are organics present? What is the asteroid physical structure? How would the object respond to impact/deflection?We have begun development of a miniature infrared point spectrometer, a cornerstone of the Intrepid payload, covering both shortwave infrared (SWIR) and mid-infrared (MIR) spectral bands. The spectrometer is designed with a compact 2U form-factor, making it both relevant to Intrepid and implementable on a CubeSat. The combination of SWIR and MIR in a single integrated instrument would enable robust compositional interpretations from a single dataset combining both solar reflectance and thermal emission spectroscopy. These measurements would be crucial to determining the quantity and nature of water present.
Prasad, Thazhe Kootteri; Poneti, Giordano; Sorace, Lorenzo; Rodriguez-Douton, Maria Jesus; Barra, Anne-Laure; Neugebauer, Petr; Costantino, Luca; Sessoli, Roberta; Cornia, Andrea
2012-07-21
Tetrairon(III) complexes known as "ferric stars" have been functionalized with azobenzene groups to investigate the effect of light-induced trans-cis isomerization on single-molecule magnet (SMM) behaviour. According to DC magnetic data and EPR spectroscopy, clusters dispersed in polystyrene (4% w/w) exhibit the same spin (S = 5) and magnetic anisotropy as bulk samples. Ligand photoisomerization, achieved by irradiation at 365 nm, has no detectable influence on static magnetic properties. However, it induces a small but significant acceleration of magnetic relaxation as probed by AC susceptometry. The pristine behaviour can be almost quantitatively recovered by irradiation with white light. Our studies demonstrate that magnetic and optical bistability can be made to coexist in SMM materials, which are of current interest in molecular spintronics.
Single-shot detection of bacterial endospores via coherent Raman spectroscopy.
Pestov, Dmitry; Wang, Xi; Ariunbold, Gombojav O; Murawski, Robert K; Sautenkov, Vladimir A; Dogariu, Arthur; Sokolov, Alexei V; Scully, Marlan O
2008-01-15
Recent advances in coherent Raman spectroscopy hold exciting promise for many potential applications. For example, a technique, mitigating the nonresonant four-wave-mixing noise while maximizing the Raman-resonant signal, has been developed and applied to the problem of real-time detection of bacterial endospores. After a brief review of the technique essentials, we show how extensions of our earlier experimental work [Pestov D, et al. (2007) Science 316:265-268] yield single-shot identification of a small sample of Bacillus subtilis endospores (approximately 10(4) spores). The results convey the utility of the technique and its potential for "on-the-fly" detection of biohazards, such as Bacillus anthracis. The application of optimized coherent anti-Stokes Raman scattering scheme to problems requiring chemical specificity and short signal acquisition times is demonstrated.
NASA Astrophysics Data System (ADS)
Zhang, Sheng; Li, Jie; Bartell, Jason; Lammert, Paul; Crespi, Vincent; Schiffer, Peter
2011-03-01
We have studied magnetic moment configurations of clusters of single-domain ferromagnetic islands in different geometries. The magnetic moments of these clusters are imaged by MFM after rotational demagnetization, following our previous protocols. We observed that two types of the clusters showed a significant imbalance of their two-fold degenerate ground states after demagnetization, and this inequality is correlated to the rotational direction of the demagnetization. A similar imbalance was also found in nano-scale rings with a small gap: the chirality of their magnetic state can be precisely controlled by the rotational direction during demagnetization. We acknowledge the financial support from DOE and Army Research Office. We are grateful to Prof. Chris Leighton and Mike Erickson for assistance with sample preparation.
Shock and Release Behaviour of Silica Based Granular Materials
NASA Astrophysics Data System (ADS)
Braithwaite, Chris; Perry, James; Taylor, Nicholas
2017-06-01
A large number of experiments have been conducted using the Cavendish single stage gas gun to investigate the dynamic properties of sand. The results included successful measurements of release in dry materials, demonstrating that this is markedly different to the loading path. The effect of moisture was examined and shown to be strongest where the material was close to saturation, at which point the microstructure of the exact sample configuration plays a significant role in the response. Finally, the effect of sample morphology was probed, and whilst it was found to be significant at low rates, in the shock regime impedance appears to be more strongly influenced by the presence of moisture or a fraction of small particle size debris.
Decision tree modeling using R.
Zhang, Zhongheng
2016-08-01
In machine learning field, decision tree learner is powerful and easy to interpret. It employs recursive binary partitioning algorithm that splits the sample in partitioning variable with the strongest association with the response variable. The process continues until some stopping criteria are met. In the example I focus on conditional inference tree, which incorporates tree-structured regression models into conditional inference procedures. While growing a single tree is subject to small changes in the training data, random forests procedure is introduced to address this problem. The sources of diversity for random forests come from the random sampling and restricted set of input variables to be selected. Finally, I introduce R functions to perform model based recursive partitioning. This method incorporates recursive partitioning into conventional parametric model building.
Universal mechanism of thermo-mechanical deformation in metallic glasses
Dmowski, W.; Tong, Y.; Iwashita, T.; ...
2015-02-11
Here we investigated the atomistic structure of metallic glasses subjected to thermo-mechanical creep deformation using high energy x-ray diffraction and molecular dynamics simulation. The experiments were performed in-situ, at high temperatures as a time dependent deformation in the elastic regime, and ex-situ on samples quenched under stress. We show that all the anisotropic structure functions of the samples undergone thermo-mechanical creep can be scaled into a single curve, regardless of the magnitude of anelastic strain, stress level and the sign of the stress, demonstrating universal behavior and pointing to unique atomistic unit of anelastic deformation. The structural changes due tomore » creep are strongly localized within the second nearest neighbors, involving only a small group of atoms.« less
NASA Astrophysics Data System (ADS)
Liu, Yong; Zhou, Lin; Sun, Kewei; Straszheim, Warren E.; Tanatar, Makariy A.; Prozorov, Ruslan; Lograsso, Thomas A.
2018-02-01
We present a thorough study of doping dependent magnetic hysteresis and relaxation characteristics in single crystals of (B a1 -xKx ) F e2A s2 (0.18 ≤x ≤1 ). The critical current density Jc reaches maximum in the underdoped sample x =0.26 and then decreases in the optimally doped and overdoped samples. Meanwhile, the magnetic relaxation rate S rapidly increases and the flux creep activation barrier U0 sharply decreases in the overdoped sample x =0.70 . These results suggest that vortex pinning is very strong in the underdoped regime, but it is greatly reduced in the optimally doped and overdoped regime. Transmission electron microscope (TEM) measurements reveal the existence of dislocations and inclusions in all three studied samples x =0.38 , 0.46, and 0.65. An investigation of the paramagnetic Meissner effect (PME) suggests that spatial variations in Tc become small in the samples x =0.43 and 0.46, slightly above the optimal doping levels. Our results support that two types of pinning sources dominate the (B a1 -xKx ) F e2A s2 crystals: (i) strong δl pinning, which results from the fluctuations in the mean free path l and δ Tc pinning from the spatial variations in Tc in the underdoped regime, and (ii) weak δ Tc pinning in the optimally doped and overdoped regime.
Liu, Yong; Zhou, Lin; Sun, Kewei; ...
2018-02-16
Here, we present a thorough study of doping dependent magnetic hysteresis and relaxation characteristics in single crystals of (Ba 1-xK x) Fe 2As 2 (0.18 ≤ x ≤ 1). The critical current density J c reaches maximum in the underdoped sample x = 0.26 and then decreases in the optimally doped and overdoped samples. Meanwhile, the magnetic relaxation rate S rapidly increases and the flux creep activation barrier U 0 sharply decreases in the overdoped sample x = 0.70. These results suggest that vortex pinning is very strong in the underdoped regime, but it is greatly reduced in the optimallymore » doped and overdoped regime. Transmission electron microscope (TEM) measurements reveal the existence of dislocations and inclusions in all three studied samples x = 0.38, 0.46, and 0.65. An investigation of the paramagnetic Meissner effect (PME) suggests that spatial variations in T c become small in the samples x = 0.43 and 0.46, slightly above the optimal doping levels. Our results support that two types of pinning sources dominate the (Ba 1-xK x) Fe 2As 2 crystals: (i) strong δl pinning, which results from the fluctuations in the mean free path l and δT c pinning from the spatial variations in T c in the underdoped regime, and (ii) weak δT c pinning in the optimally doped and overdoped regime.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Yong; Zhou, Lin; Sun, Kewei
Here, we present a thorough study of doping dependent magnetic hysteresis and relaxation characteristics in single crystals of (Ba 1-xK x) Fe 2As 2 (0.18 ≤ x ≤ 1). The critical current density J c reaches maximum in the underdoped sample x = 0.26 and then decreases in the optimally doped and overdoped samples. Meanwhile, the magnetic relaxation rate S rapidly increases and the flux creep activation barrier U 0 sharply decreases in the overdoped sample x = 0.70. These results suggest that vortex pinning is very strong in the underdoped regime, but it is greatly reduced in the optimallymore » doped and overdoped regime. Transmission electron microscope (TEM) measurements reveal the existence of dislocations and inclusions in all three studied samples x = 0.38, 0.46, and 0.65. An investigation of the paramagnetic Meissner effect (PME) suggests that spatial variations in T c become small in the samples x = 0.43 and 0.46, slightly above the optimal doping levels. Our results support that two types of pinning sources dominate the (Ba 1-xK x) Fe 2As 2 crystals: (i) strong δl pinning, which results from the fluctuations in the mean free path l and δT c pinning from the spatial variations in T c in the underdoped regime, and (ii) weak δT c pinning in the optimally doped and overdoped regime.« less
Yang, Yang; DeGruttola, Victor
2016-01-01
Traditional resampling-based tests for homogeneity in covariance matrices across multiple groups resample residuals, that is, data centered by group means. These residuals do not share the same second moments when the null hypothesis is false, which makes them difficult to use in the setting of multiple testing. An alternative approach is to resample standardized residuals, data centered by group sample means and standardized by group sample covariance matrices. This approach, however, has been observed to inflate type I error when sample size is small or data are generated from heavy-tailed distributions. We propose to improve this approach by using robust estimation for the first and second moments. We discuss two statistics: the Bartlett statistic and a statistic based on eigen-decomposition of sample covariance matrices. Both statistics can be expressed in terms of standardized errors under the null hypothesis. These methods are extended to test homogeneity in correlation matrices. Using simulation studies, we demonstrate that the robust resampling approach provides comparable or superior performance, relative to traditional approaches, for single testing and reasonable performance for multiple testing. The proposed methods are applied to data collected in an HIV vaccine trial to investigate possible determinants, including vaccine status, vaccine-induced immune response level and viral genotype, of unusual correlation pattern between HIV viral load and CD4 count in newly infected patients. PMID:22740584
Yang, Yang; DeGruttola, Victor
2012-06-22
Traditional resampling-based tests for homogeneity in covariance matrices across multiple groups resample residuals, that is, data centered by group means. These residuals do not share the same second moments when the null hypothesis is false, which makes them difficult to use in the setting of multiple testing. An alternative approach is to resample standardized residuals, data centered by group sample means and standardized by group sample covariance matrices. This approach, however, has been observed to inflate type I error when sample size is small or data are generated from heavy-tailed distributions. We propose to improve this approach by using robust estimation for the first and second moments. We discuss two statistics: the Bartlett statistic and a statistic based on eigen-decomposition of sample covariance matrices. Both statistics can be expressed in terms of standardized errors under the null hypothesis. These methods are extended to test homogeneity in correlation matrices. Using simulation studies, we demonstrate that the robust resampling approach provides comparable or superior performance, relative to traditional approaches, for single testing and reasonable performance for multiple testing. The proposed methods are applied to data collected in an HIV vaccine trial to investigate possible determinants, including vaccine status, vaccine-induced immune response level and viral genotype, of unusual correlation pattern between HIV viral load and CD4 count in newly infected patients.
Ice crystal precipitation at Dome C site (East Antarctica)
NASA Astrophysics Data System (ADS)
Santachiara, G.; Belosi, F.; Prodi, F.
2016-01-01
For the first time, falling ice crystals were collected on glass slides covered with a thin layer of 2% formvar in chloroform at the Dome Concordia site (Dome C), Antarctica. Samplings were performed in the framework of the 27th Italian Antarctica expedition of the Italian National Program for Research in Antarctica in the period 21 February-6 August 2012. Events of clear-sky precipitations and precipitations from clouds were considered and the replicas obtained were examined under Scanning Electron Microscope (SEM). Several shapes of ice crystals were identified, including ;diamond dust; (plates, pyramids, hollow and solid columns), and crystal aggregates varying in complexity. Single events often contained both small (10 μm to 50 μm) and large (hundreds of microns) crystals, suggesting that crystals can form simultaneously near the ground (height of a few hundred metres) and at higher layers (height of thousands of metres). Images of sampled crystal replicas showed that single bullets are not produced separately, but by the disintegration of combinations of bullets. Rimed ice crystals were absent in the Dome C samples, i.e. the only mode of crystal growth was water vapour diffusion. On considering the aerosol in the sampled crystals, we reached the conclusion that inertial impaction, interception and Brownian motion were insufficient to explain the scavenged aerosol. We therefore presume that phoretic forces play a role in scavenging during the crystal growth process.
Mars rover sample return mission utilizing in situ production of the return propellants
NASA Technical Reports Server (NTRS)
Bruckner, A. P.; Nill, L.; Schubert, H.; Thill, B.; Warwick, R.
1993-01-01
This paper presents an unmanned Mars sample return mission that utilizes propellants manufactured in situ from the Martian atmosphere for the return trip. A key goal of the mission is to demonstrate the considerable benefits that can be realized through the use of indigenous resources and to test the viability of this approach as a precursor to manned missions to Mars. Two in situ propellant combinations, methane/oxygen and carbon monoxide/oxygen, are compared to imported terrestrial hydrogen/oxygen within a single mission architecture, using a single Earth launch vehicle. The mission is assumed to be launched from Earth in 2003. Upon reaching Mars, the landing vehicle aerobrakes, deploys a small satellite, and lands on the Martian surface. Once on the ground, the propellant production unit is activated, and the product gases are liquefied and stored in the empty tanks of the Earth Return Vehicle (ERV). Power for these activities is provided by a dynamic isotope power system. A semiautonomous rover, powered by the indigenous propellants, gathers between 25 and 30 kg of soil and rock samples which are loaded aboard the ERV for return to Earth. After a surface stay time of approximately 1.5 years, the ERV leaves Mars for the return voyage to Earth. When the vehicle reaches the vicinity of Earth, the sample return capsule detaches, and is captured and circularized in LEO via aerobraking maneuvers.
Thermoelectric properties of cobalt antimonide>-based skutterudites
NASA Astrophysics Data System (ADS)
Yang, Jian
Solid state cooling and power generation based on thermoelectric principles are regarded as one of the technologies with the potential of solving the current energy crisis. Thermoelectric devices could be widely used in waste heat recovery, small scale power generation and refrigeration. It has no moving parts and is environmental friendly. The limitation to its application is due to its low efficiency. Most of the current commercialized thermoelectric materials have figure of merit (ZT) around 1. To be comparable with kitchen refrigerator, ZT≃ 3 is required at room temperature. Skutterudites have emerged as member of the novel materials, which potentially have a higher ZT. In the dissertation, my investigation will be focused on the optimization of CoSb3-based skutterudites. Starting with Co and Sb elements, CoSb3 will form through a high energy ball mill. Unfortunately, even after 20 hours, only a small percentage of the powders have transformed in into CoSb3. Then the powders will be compacted into bulk samples by DC-controlled hot press. CoSb3 single phase will form after press. Characterization of the structure and thermoelectric properties will be presented with details. The effects of synthesis conditions on thermoelectric properties of skutterudites were studied and discussed. Several possible methods of improving the ZT of N type skutterudites were applied. The highest obtained ZT thus far is ˜1.2 from Yb doped CoSb3. For a group of samples with nominal composition YbxCo4Sb12, the increased Yb concentration in our samples not only enhanced the power factor due to electron doping effect but also decreased the thermal conductivity due to a stronger rattling effect. In addition, the increased grain boundary density per unit volume due to the small grains in our bulk skutterudite materials may have also helped to enhance the phonon scattering and thus to reduce the thermal conductivity. Single and double doping methods with different combinations were also tried. So far, none of them have surpassed ZT=1.2. Mixing different materials with Yb 0.35Co4Sb12 so far to increase the phonon scattering was also performed. No dramatic thermal conductivity reduction was observed. Small amounts of Fe/Mn substitution on Co sites will decrease the power factor to undesired degrees. Some results with Nd filled P type sample will be briefly introduced. P type samples are also obtained through substitution on Sb site. Preliminary work on preparing the electrode for CoSb3 will be presented in the dissertation. CoSi2 has low resistivity, and a similar coefficient of thermal expansion (CTE) as of doped CoSb3. It is good electrode candidate. DC-controlled hot press is used to make the contact. Thermal stability of the contact was tested. Small cracks will form in the contact area, further improvement is necessary. Finally, my previous work on ZnO nanowire growth is briefly introduced. Large throughput of ZnO nanowire could be obtained with NaCl as the support to promote the conversion of Zn powder to ZnO.
High-throughput screening based on label-free detection of small molecule microarrays
NASA Astrophysics Data System (ADS)
Zhu, Chenggang; Fei, Yiyan; Zhu, Xiangdong
2017-02-01
Based on small-molecule microarrays (SMMs) and oblique-incidence reflectivity difference (OI-RD) scanner, we have developed a novel high-throughput drug preliminary screening platform based on label-free monitoring of direct interactions between target proteins and immobilized small molecules. The screening platform is especially attractive for screening compounds against targets of unknown function and/or structure that are not compatible with functional assay development. In this screening platform, OI-RD scanner serves as a label-free detection instrument which is able to monitor about 15,000 biomolecular interactions in a single experiment without the need to label any biomolecule. Besides, SMMs serves as a novel format for high-throughput screening by immobilization of tens of thousands of different compounds on a single phenyl-isocyanate functionalized glass slide. Based on the high-throughput screening platform, we sequentially screened five target proteins (purified target proteins or cell lysate containing target protein) in high-throughput and label-free mode. We found hits for respective target protein and the inhibition effects for some hits were confirmed by following functional assays. Compared to traditional high-throughput screening assay, the novel high-throughput screening platform has many advantages, including minimal sample consumption, minimal distortion of interactions through label-free detection, multi-target screening analysis, which has a great potential to be a complementary screening platform in the field of drug discovery.
Alvarado, David M; Yang, Ping; Druley, Todd E; Lovett, Michael; Gurnett, Christina A
2014-06-01
Despite declining sequencing costs, few methods are available for cost-effective single-nucleotide polymorphism (SNP), insertion/deletion (INDEL) and copy number variation (CNV) discovery in a single assay. Commercially available methods require a high investment to a specific region and are only cost-effective for large samples. Here, we introduce a novel, flexible approach for multiplexed targeted sequencing and CNV analysis of large genomic regions called multiplexed direct genomic selection (MDiGS). MDiGS combines biotinylated bacterial artificial chromosome (BAC) capture and multiplexed pooled capture for SNP/INDEL and CNV detection of 96 multiplexed samples on a single MiSeq run. MDiGS is advantageous over other methods for CNV detection because pooled sample capture and hybridization to large contiguous BAC baits reduces sample and probe hybridization variability inherent in other methods. We performed MDiGS capture for three chromosomal regions consisting of ∼ 550 kb of coding and non-coding sequence with DNA from 253 patients with congenital lower limb disorders. PITX1 nonsense and HOXC11 S191F missense mutations were identified that segregate in clubfoot families. Using a novel pooled-capture reference strategy, we identified recurrent chromosome chr17q23.1q23.2 duplications and small HOXC 5' cluster deletions (51 kb and 12 kb). Given the current interest in coding and non-coding variants in human disease, MDiGS fulfills a niche for comprehensive and low-cost evaluation of CNVs, coding, and non-coding variants across candidate regions of interest. © The Author(s) 2014. Published by Oxford University Press on behalf of Nucleic Acids Research.
Diakaridia, Sanogo; Pan, Yue; Xu, Pengbai; Zhou, Dengwang; Wang, Benzhang; Teng, Lei; Lu, Zhiwei; Ba, Dexin; Dong, Yongkang
2017-07-24
In distributed Brillouin optical fiber sensor when the length of the perturbation to be detected is much smaller than the spatial resolution that is defined by the pulse width, the measured Brillouin gain spectrum (BGS) experiences two or multiple peaks. In this work, we propose and demonstrate a technique using differential pulse pair Brillouin optical time-domain analysis (DPP-BOTDA) based on double-peak BGS to enhance small-scale events detection capability, where two types of single mode fiber (main fiber and secondary fiber) with 116 MHz Brillouin frequency shift (BFS) difference have been used. We have realized detection of a 5-cm hot spot at the far end of 24-km single mode fiber by employing a 50-cm spatial resolution DPP-BOTDA with only 1GS/s sampling rate (corresponding to 10 cm/point). The BFS at the far end of 24-km sensing fiber has been measured with 0.54 MHz standard deviation which corresponds to a 0.5°C temperature accuracy. This technique is simple and cost effective because it is implemented using the similar experimental setup of the standard BOTDA, however, it should be noted that the consecutive small-scale events have to be separated by a minimum length corresponding to the spatial resolution defined by the pulse width difference.
Super-global distortion correction for a rotational C-arm x-ray image intensifier.
Liu, R R; Rudin, S; Bednarek, D R
1999-09-01
Image intensifier (II) distortion changes as a function of C-arm rotation angle because of changes in the orientation of the II with the earth's or other stray magnetic fields. For cone-beam computed tomography (CT), distortion correction for all angles is essential. The new super-global distortion correction consists of a model to continuously correct II distortion not only at each location in the image but for every rotational angle of the C arm. Calibration bead images were acquired with a standard C arm in 9 in. II mode. The super-global (SG) model is obtained from the single-plane global correction of the selected calibration images with given sampling angle interval. The fifth-order single-plane global corrections yielded a residual rms error of 0.20 pixels, while the SG model yielded a rms error of 0.21 pixels, a negligibly small difference. We evaluated the accuracy dependence of the SG model on various factors, such as the single-plane global fitting order, SG order, and angular sampling interval. We found that a good SG model can be obtained using a sixth-order SG polynomial fit based on the fifth-order single-plane global correction, and that a 10 degrees sampling interval was sufficient. Thus, the SG model saves processing resources and storage space. The residual errors from the mechanical errors of the x-ray system were also investigated, and found comparable with the SG residual error. Additionally, a single-plane global correction was done in the cylindrical coordinate system, and physical information about pincushion distortion and S distortion were observed and analyzed; however, this method is not recommended due to a lack of calculational efficiency. In conclusion, the SG model provides an accurate, fast, and simple correction for rotational C-arm images, which may be used for cone-beam CT.
NASA Astrophysics Data System (ADS)
Na, Suok-Min; Smith, Malcolm; Flatau, Alison B.
2018-06-01
In this work, deformation mechanism related to recrystallization behavior in single-crystal disks of Galfenol (Fe-Ga alloy) was investigated to gain insights into the influence of crystal orientations on structural changes and selective grain growth that take place during secondary recrystallization. We started with the three kinds of single-crystal samples with (011)[100], (001)[100], and (001)[110] orientations, which were rolled and annealed to promote the formation of different grain structures and texture evolutions. The initial Goss-oriented (011)[100] crystal mostly rotated into {111}<112> orientations with twofold symmetry and shear band structures by twinning resulted in the exposure of rolled surface along {001}<110> orientation during rolling. In contrast, the Cube-oriented (001)[100] single crystal had no change in texture during rolling with the thickness reduction up to 50 pct. The {123}<111> slip systems were preferentially activated in these single crystals during deformation as well as {112}<111> slip systems that are known to play a role in primary slip of body-centered cubic (BCC) materials such as α-iron and Fe-Si alloys. After annealing, the deformed Cube-oriented single crystal had a small fraction (<10 pct) of recrystallized Goss-oriented grains. The weak Goss component remained in the shear bands of the 50 pct rolled Goss-oriented single crystal, and it appeared to be associated with coalescence of subgrains inside shear band structures during primary recrystallization. Rolling of the (001)[110] single crystal led to the formation of a tilted (001)[100] component close to the <120> orientation, associated with {123}<111> slip systems as well. This was expected to provide potential sites of nucleation for secondary recrystallization; however, no Goss- and Cube-oriented components actually developed in this sample during secondary recrystallization. Those results illustrated how the recrystallization behavior can be influenced by deformed structure and the slip systems.
Williams, Jessica A R; Schult, Tamara M; Nelson, Candace C; Cabán-Martinez, Alberto J; Katz, Jeffrey N; Wagner, Gregory R; Pronk, Nicolaas P; Sorensen, Glorian; McLellan, Deborah L
2016-05-01
To conduct validation and dimensionality analyses for an existing measure of the integration of worksite health protection and health promotion approaches. A survey of small to medium size employers located in the United States was conducted between October 2013 and March 2014 (N = 115). A survey of Department of Veterans Affairs (VA) administrative parents was also conducted from June to July 2014 (N = 140). Exploratory factor analysis (EFA) was used to determine the dimensionality of the Integration Score in each sample. Using EFA, both samples indicated the presence of one unified factor. The VA survey indicated that customization improves the relevance of the Integration Score for different types of organizations. The Integration Score is a valid index for assessing the integration of worksite health protection and health promotion approaches and is customizable based on industry. The Integration Score may be used as a single metric for assessing the integration of worksite health protection and health promotion approaches in differing work contexts.
Tang, Vera A; Renner, Tyler M; Fritzsche, Anna K; Burger, Dylan; Langlois, Marc-André
2017-12-19
Retroviruses and small EVs overlap in size, buoyant densities, refractive indices and share many cell-derived surface markers making them virtually indistinguishable by standard biochemical methods. This poses a significant challenge when purifying retroviruses for downstream analyses or for phenotypic characterization studies of markers on individual virions given that EVs are a major contaminant of retroviral preparations. Nanoscale flow cytometry (NFC), also called flow virometry, is an adaptation of flow cytometry technology for the analysis of individual nanoparticles such as extracellular vesicles (EVs) and retroviruses. In this study we systematically optimized NFC parameters for the detection of retroviral particles in the range of 115-130 nm, including viral production, sample labeling, laser power and voltage settings. By using the retroviral envelope glycoprotein as a selection marker, and evaluating a number of fluorescent dyes and labeling methods, we demonstrate that it is possible to confidently distinguish retroviruses from small EVs by NFC. Our findings make it now possible to individually phenotype genetically modified retroviral particles that express a fluorescent envelope glycoprotein without removing EV contaminants from the sample.
Structural characterization of the human cerebral myelin sheath by small angle x-ray scattering
NASA Astrophysics Data System (ADS)
DeFelici, M.; Felici, R.; Ferrero, C.; Tartari, A.; Gambaccini, M.; Finet, S.
2008-10-01
Myelin is a multi-lamellar membrane surrounding neuronal axons and increasing their conduction velocity. When investigated by small-angle x-ray scattering (SAXS), the lamellar quasi-periodical arrangement of the myelin sheath gives rise to distinct peaks, which allow the determination of its molecular organization and the dimensions of its substructures. In this study we report on the myelin sheath structural determination carried out on a set of human brain tissue samples coming from surgical biopsies of two patients: a man around 60 and a woman nearly 90 years old. The samples were extracted either from white or grey cerebral matter and did not undergo any manipulation or chemical-physical treatment, which could possibly have altered their structure, except dipping them into a formalin solution for their conservation. Analysis of the scattered intensity from white matter of intact human cerebral tissue allowed the evaluation not only of the myelin sheath periodicity but also of its electronic charge density profile. In particular, the thicknesses of the cytoplasm and extracellular regions were established, as well as those of the hydrophilic polar heads and hydrophobic tails of the lipid bilayer. SAXS patterns were measured at several locations on each sample in order to establish the statistical variations of the structural parameters within a single sample and among different samples. This work demonstrates that a detailed structural analysis of the myelin sheath can also be carried out in randomly oriented samples of intact human white matter, which is of importance for studying the aetiology and evolution of the central nervous system pathologies inducing myelin degeneration.
Droplet microfluidic technology for single-cell high-throughput screening.
Brouzes, Eric; Medkova, Martina; Savenelli, Neal; Marran, Dave; Twardowski, Mariusz; Hutchison, J Brian; Rothberg, Jonathan M; Link, Darren R; Perrimon, Norbert; Samuels, Michael L
2009-08-25
We present a droplet-based microfluidic technology that enables high-throughput screening of single mammalian cells. This integrated platform allows for the encapsulation of single cells and reagents in independent aqueous microdroplets (1 pL to 10 nL volumes) dispersed in an immiscible carrier oil and enables the digital manipulation of these reactors at a very high-throughput. Here, we validate a full droplet screening workflow by conducting a droplet-based cytotoxicity screen. To perform this screen, we first developed a droplet viability assay that permits the quantitative scoring of cell viability and growth within intact droplets. Next, we demonstrated the high viability of encapsulated human monocytic U937 cells over a period of 4 days. Finally, we developed an optically-coded droplet library enabling the identification of the droplets composition during the assay read-out. Using the integrated droplet technology, we screened a drug library for its cytotoxic effect against U937 cells. Taken together our droplet microfluidic platform is modular, robust, uses no moving parts, and has a wide range of potential applications including high-throughput single-cell analyses, combinatorial screening, and facilitating small sample analyses.
Each cell counts: Hematopoiesis and immunity research in the era of single cell genomics.
Jaitin, Diego Adhemar; Keren-Shaul, Hadas; Elefant, Naama; Amit, Ido
2015-02-01
Hematopoiesis and immunity are mediated through complex interactions between multiple cell types and states. This complexity is currently addressed following a reductionist approach of characterizing cell types by a small number of cell surface molecular features and gross functions. While the introduction of global transcriptional profiling technologies enabled a more comprehensive view, heterogeneity within sampled populations remained unaddressed, obscuring the true picture of hematopoiesis and immune system function. A critical mass of technological advances in molecular biology and genomics has enabled genome-wide measurements of single cells - the fundamental unit of immunity. These new advances are expected to boost detection of less frequent cell types and fuzzy intermediate cell states, greatly expanding the resolution of current available classifications. This new era of single-cell genomics in immunology research holds great promise for further understanding of the mechanisms and circuits regulating hematopoiesis and immunity in both health and disease. In the near future, the accuracy of single-cell genomics will ultimately enable precise diagnostics and treatment of multiple hematopoietic and immune related diseases. Copyright © 2015 Elsevier Ltd. All rights reserved.
Black, Dolores Archuleta; Robinson, William H.; Wilcox, Ian Zachary; ...
2015-08-07
Single event effects (SEE) are a reliability concern for modern microelectronics. Bit corruptions can be caused by single event upsets (SEUs) in the storage cells or by sampling single event transients (SETs) from a logic path. Likewise, an accurate prediction of soft error susceptibility from SETs requires good models to convert collected charge into compact descriptions of the current injection process. This paper describes a simple, yet effective, method to model the current waveform resulting from a charge collection event for SET circuit simulations. The model uses two double-exponential current sources in parallel, and the results illustrate why a conventionalmore » model based on one double-exponential source can be incomplete. Furthermore, a small set of logic cells with varying input conditions, drive strength, and output loading are simulated to extract the parameters for the dual double-exponential current sources. As a result, the parameters are based upon both the node capacitance and the restoring current (i.e., drive strength) of the logic cell.« less
Fu, Riqiang; Hernández-Maldonado, Arturo J
2018-05-24
A small flip-angle pulse direct polarization is the simplest method commonly used to quantify various compositions in many materials applications. This method sacrifices the sensitivity per scan in exchange for rapid repeating of data acquisition for signal accumulation. In addition, the resulting spectrum often encounters artifacts from background signals from probe components and/or from acoustic rings leading to a distorted baseline, especially in low-γ nuclei and wideline NMR. In this work, a multi-acquisition scheme is proposed to boost the sensitivity per scan and at the same time effectively suppress these artifacts. Here, an adiabatic inversion pulse is first applied in order to bring the magnetization from the +z to -z axis and then a small flip-angle pulse excitation is used before the data acquisition. Right after the first acquisition, the adiabatic inversion pulse is applied again to flip the magnetization back to the +z axis. The second data acquisition takes place after another small flip-angle pulse excitation. The difference between the two consecutive acquisitions cancels out any artifacts, while the wanted signals are accumulated. This acquisition process can be repeated many times before going into next scan. Therefore, by acquiring the signals multiple times in a single scan the sensitivity is improved. A mixture sample of flufenamic acid and 3,5-difluorobenzoic acid and a titanium silicate sample have been used to demonstrate the advantages of this newly proposed method. Copyright © 2018 Elsevier Inc. All rights reserved.
The Beta Pictoris Phenomenon in Young Stars With Accreting Gas
NASA Technical Reports Server (NTRS)
Grady, Carol A.
1999-01-01
Program Hae2BPIC resulted in usable ISO spectra of three young, Herbig Ae stars: HR 5999 (A7e, t=0.6 Myr), SV Cep (al-2e, t=1-3 Myr), and MW Vul (Al-2e, t=1-3 Myr). While too small a sample to pursue our original goal of surveying the silicate emission in these young, protoplanetary disk systems, comparison of these data with ground-based IR spectra, and published ISO observations of other HAe stars (especially the posters at PPIV) reveals the following: The known binary stars in the sample show signatures of partially crystal line silicate features by t=0.6 Myr, at an epoch when ostensibly single Herbig Ae stars have substantially stronger silicate emission dominated by amorphous grains. The known binary stars also show deficits in the optically thick continuum flux relative to coeval single stars. Comparison of ISO spectra indicates that the flux deficit seen in WD 163296 over 10-100 microns relative to AB Aur reflects a real deficit of material interior to 300.
The reliability and stability of visual working memory capacity.
Xu, Z; Adam, K C S; Fang, X; Vogel, E K
2018-04-01
Because of the central role of working memory capacity in cognition, many studies have used short measures of working memory capacity to examine its relationship to other domains. Here, we measured the reliability and stability of visual working memory capacity, measured using a single-probe change detection task. In Experiment 1, the participants (N = 135) completed a large number of trials of a change detection task (540 in total, 180 each of set sizes 4, 6, and 8). With large numbers of both trials and participants, reliability estimates were high (α > .9). We then used an iterative down-sampling procedure to create a look-up table for expected reliability in experiments with small sample sizes. In Experiment 2, the participants (N = 79) completed 31 sessions of single-probe change detection. The first 30 sessions took place over 30 consecutive days, and the last session took place 30 days later. This unprecedented number of sessions allowed us to examine the effects of practice on stability and internal reliability. Even after much practice, individual differences were stable over time (average between-session r = .76).
Paul, Topon Kumar; Iba, Hitoshi
2009-01-01
In order to get a better understanding of different types of cancers and to find the possible biomarkers for diseases, recently, many researchers are analyzing the gene expression data using various machine learning techniques. However, due to a very small number of training samples compared to the huge number of genes and class imbalance, most of these methods suffer from overfitting. In this paper, we present a majority voting genetic programming classifier (MVGPC) for the classification of microarray data. Instead of a single rule or a single set of rules, we evolve multiple rules with genetic programming (GP) and then apply those rules to test samples to determine their labels with majority voting technique. By performing experiments on four different public cancer data sets, including multiclass data sets, we have found that the test accuracies of MVGPC are better than those of other methods, including AdaBoost with GP. Moreover, some of the more frequently occurring genes in the classification rules are known to be associated with the types of cancers being studied in this paper.
MASS SPECTROMETRY IMAGING FOR DRUGS AND METABOLITES
Greer, Tyler; Sturm, Robert; Li, Lingjun
2011-01-01
Mass spectrometric imaging (MSI) is a powerful analytical technique that provides two- and three-dimensional spatial maps of multiple compounds in a single experiment. This technique has been routinely applied to protein, peptide, and lipid molecules with much less research reporting small molecule distributions, especially pharmaceutical drugs. This review’s main focus is to provide readers with an up-to-date description of the substrates and compounds that have been analyzed for drug and metabolite composition using MSI technology. Additionally, ionization techniques, sample preparation, and instrumentation developments are discussed. PMID:21515430
Generation of sub-femtoliter droplet by T-junction splitting on microfluidic chips
NASA Astrophysics Data System (ADS)
Yang, Yu-Jun; Feng, Xuan; Xu, Na; Pang, Dai-Wen; Zhang, Zhi-Ling
2013-03-01
In the paper, sub-femtoliter droplets were easily produced by droplet splitting at a simple T-junction with orifice, which did not need expensive equipments, complex photolithography skill, or high energy input. The volume of the daughter droplet was not limited by channel size but controlled by channel geometry and fluidic characteristic. Moreover, single bead sampling and bead quantification in different orders of magnitude of droplet volumes were investigated. The droplets split at our T-junction chip had small volume and monodispersed size and could be produced efficiently, orderly, and controllably.
NASA Astrophysics Data System (ADS)
Ackerstaff, K.; Bisplinghoff, J.; Bollmann, R.; Cloth, P.; Dohrmann, F.; Diehl, O.; Dorner, G.; Drüke, V.; Engelhardt, H. J.; Eisenhardt, S.; Ernst, J.; Eversheim, P. D.; Filges, D.; Fritz, S.; Gasthuber, M.; Gebel, R.; Gross, A.; Gross-Hardt, R.; Hinterberger, F.; Jahn, R.; Lahr, U.; Langkau, R.; Lippert, G.; Mayer-Kuckuk, T.; Maschuw, R.; Mertler, G.; Metsch, B.; Mosel, F.; Paetz gen. Schieck, H.; Petry, H. R.; Prasuhn, D.; v. Przewoski, B.; Radtke, M.; Rohdjess, H.; Rosendaal, D.; von Rossen, P.; Scheid, H.; Schirm, N.; Schwandt, F.; Scobel, W.; Theis, D.; Weber, J.; Wiedmann, W.; Woller, K.; Ziegler, R.; EDDA Collaboration
1993-10-01
For the EDDA experiment at COSY, the response of the small, linear focused photomultipliers Hamamatsu R 1450 and R 1355 has been studied with fast light pulses generating yields up to 2 × 10 3 photoelectrons/cm 2 or peak currents of 24 mA. Linearity was obtained with a tapered bleeder chain at a tolerable loss of gain. The serial test of altogether 140 photomultipliers revealed the close correlation between single electron and amplitude resolution. The influence of the photoelectron statistics on this correlation is discussed.
Bray, Mark-Anthony; Gustafsdottir, Sigrun M; Rohban, Mohammad H; Singh, Shantanu; Ljosa, Vebjorn; Sokolnicki, Katherine L; Bittker, Joshua A; Bodycombe, Nicole E; Dančík, Vlado; Hasaka, Thomas P; Hon, Cindy S; Kemp, Melissa M; Li, Kejie; Walpita, Deepika; Wawer, Mathias J; Golub, Todd R; Schreiber, Stuart L; Clemons, Paul A; Shamji, Alykhan F
2017-01-01
Abstract Background Large-scale image sets acquired by automated microscopy of perturbed samples enable a detailed comparison of cell states induced by each perturbation, such as a small molecule from a diverse library. Highly multiplexed measurements of cellular morphology can be extracted from each image and subsequently mined for a number of applications. Findings This microscopy dataset includes 919 265 five-channel fields of view, representing 30 616 tested compounds, available at “The Cell Image Library” (CIL) repository. It also includes data files containing morphological features derived from each cell in each image, both at the single-cell level and population-averaged (i.e., per-well) level; the image analysis workflows that generated the morphological features are also provided. Quality-control metrics are provided as metadata, indicating fields of view that are out-of-focus or containing highly fluorescent material or debris. Lastly, chemical annotations are supplied for the compound treatments applied. Conclusions Because computational algorithms and methods for handling single-cell morphological measurements are not yet routine, the dataset serves as a useful resource for the wider scientific community applying morphological (image-based) profiling. The dataset can be mined for many purposes, including small-molecule library enrichment and chemical mechanism-of-action studies, such as target identification. Integration with genetically perturbed datasets could enable identification of small-molecule mimetics of particular disease- or gene-related phenotypes that could be useful as probes or potential starting points for development of future therapeutics. PMID:28327978
[Microbiological quality of the air in "small gastronomy point"].
Wójcik-Stopczyńska, Barbara
2006-01-01
The aim of this work was the estimation of microbial contamination of the air in "small gastronomy point". The study included three places, which have been separated on the ground of their function: 1. area of subsidiaries, 2. area of distribution (sale and serving meal), 3. area of consumption. The total numbers of aerobic mesophilic bacteria, yeasts and moulds were determined by sedimentation method. Taxonomy units of fungal aerosol were also estimated. The samples of air were collected in 16 investigation points in the morning (8-8.30) and in the afternoon (14-14.30). Four series of measurements were carried out and in general 128 of air samples were tested. The results showed that numbers of bacteria, yeasts and moulds were variable and received respectively 30-3397, 0-254 and 0-138 cfu x m(-3). Microbial contamination of air changed depending on area character (the highest average count of bacteria occurred in the air of consumption area and fungi in subsidiaries area), time of a day (contamination of the air increased in the afternoon) and determination date. Only in single samples the numbers of bacteria and fungi were higher than recommended level. Pigmentary bacteria had high participation in total count of bacteria and filamentous fungi were represented mostly by Penicillium sp. and Cladosporium sp.
Zheng, Yen; Weinman, B.; Cronin, T.; Fleisher, M.Q.; Anderson, Robert F.
2003-01-01
This paper describes a rapid procedure that allows precise analysis of Mo, Cd, U and Th in sediment samples as small as 10 mg by using a novel approach that utilizes a "pseudo" isotope dilution for Th and conventional isotope dilution for Mo, Cd and U by ICP-MS. Long-term reproducibility of the method is between 2.5 and 5% with an advantage of rapid analysis on a single digestion of sediment sample and the potential of adding other elements of interest if so desired. Application of this method to two piston cores collected near the mouth of the Patuxent River in Chesapeake Bay showed that the accumulation of authigenic Mo and Cd varied in response to the changing bottom water redox conditions, with anoxia showing consistent oscillations throughout both pre-industrial and industrial times. Accumulation of authigenic U shows consistent oscillations as well, without any apparent increase in productivity related to anoxic trends. Degrees of Mo and Cd enrichment also inversely correlate to halophilic microfaunal assemblages already established as paleoclimate proxies within the bay indicating that bottom water anoxia is driven in part by the amount of freshwater discharge that the area receives. ?? 2002 Elsevier Science Ltd. All rights reserved.
Thermal, spectroscopic, and ab initio structural characterization of carprofen polymorphs.
Bruni, Giovanna; Gozzo, Fabia; Capsoni, Doretta; Bini, Marcella; Macchi, Piero; Simoncic, Petra; Berbenni, Vittorio; Milanese, Chiara; Girella, Alessandro; Ferrari, Stefania; Marini, Amedeo
2011-06-01
Commercial and recrystallized polycrystalline samples of carprofen, a nonsteroidal anti-inflammatory drug, were studied by thermal, spectroscopic, and structural techniques. Our investigations demonstrated that recrystallized sample, stable at room temperature (RT), is a single polymorphic form of carprofen (polymorph I) that undergoes an isostructural polymorphic transformation by heating (polymorph II). Polymorph II remains then metastable at ambient conditions. Commercial sample is instead a mixture of polymorphs I and II. The thermodynamic relationships between the two polymorphs were determined through the construction of an energy/temperature diagram. The ab initio structural determination performed on synchrotron X-Ray powder diffraction patterns recorded at RT on both polymorphs allowed us to elucidate, for the first time, their crystal structure. Both crystallize in the monoclinic space group type P2(1) /c, and the unit cell similarity index and the volumetric isostructurality index indicate that the temperature-induced polymorphic transformation I → II is isostructural. Polymorphs I and II are conformational polymorphs, sharing a very similar hydrogen bond network, but with different conformation of the propanoic skeleton, which produces two different packing. The small conformational change agrees with the low value of transition enthalpy obtained by differential scanning calorimetry measurements and the small internal energy computed with density functional methods. Copyright © 2011 Wiley-Liss, Inc.
Fast multi-dimensional NMR by minimal sampling
NASA Astrophysics Data System (ADS)
Kupče, Ēriks; Freeman, Ray
2008-03-01
A new scheme is proposed for very fast acquisition of three-dimensional NMR spectra based on minimal sampling, instead of the customary step-wise exploration of all of evolution space. The method relies on prior experiments to determine accurate values for the evolving frequencies and intensities from the two-dimensional 'first planes' recorded by setting t1 = 0 or t2 = 0. With this prior knowledge, the entire three-dimensional spectrum can be reconstructed by an additional measurement of the response at a single location (t1∗,t2∗) where t1∗ and t2∗ are fixed values of the evolution times. A key feature is the ability to resolve problems of overlap in the acquisition dimension. Applied to a small protein, agitoxin, the three-dimensional HNCO spectrum is obtained 35 times faster than systematic Cartesian sampling of the evolution domain. The extension to multi-dimensional spectroscopy is outlined.
Estimating Animal Abundance in Ground Beef Batches Assayed with Molecular Markers
Hu, Xin-Sheng; Simila, Janika; Platz, Sindey Schueler; Moore, Stephen S.; Plastow, Graham; Meghen, Ciaran N.
2012-01-01
Estimating animal abundance in industrial scale batches of ground meat is important for mapping meat products through the manufacturing process and for effectively tracing the finished product during a food safety recall. The processing of ground beef involves a potentially large number of animals from diverse sources in a single product batch, which produces a high heterogeneity in capture probability. In order to estimate animal abundance through DNA profiling of ground beef constituents, two parameter-based statistical models were developed for incidence data. Simulations were applied to evaluate the maximum likelihood estimate (MLE) of a joint likelihood function from multiple surveys, showing superiority in the presence of high capture heterogeneity with small sample sizes, or comparable estimation in the presence of low capture heterogeneity with a large sample size when compared to other existing models. Our model employs the full information on the pattern of the capture-recapture frequencies from multiple samples. We applied the proposed models to estimate animal abundance in six manufacturing beef batches, genotyped using 30 single nucleotide polymorphism (SNP) markers, from a large scale beef grinding facility. Results show that between 411∼1367 animals were present in six manufacturing beef batches. These estimates are informative as a reference for improving recall processes and tracing finished meat products back to source. PMID:22479559
Influence of item distribution pattern and abundance on efficiency of benthic core sampling
Behney, Adam C.; O'Shaughnessy, Ryan; Eichholz, Michael W.; Stafford, Joshua D.
2014-01-01
ore sampling is a commonly used method to estimate benthic item density, but little information exists about factors influencing the accuracy and time-efficiency of this method. We simulated core sampling in a Geographic Information System framework by generating points (benthic items) and polygons (core samplers) to assess how sample size (number of core samples), core sampler size (cm2), distribution of benthic items, and item density affected the bias and precision of estimates of density, the detection probability of items, and the time-costs. When items were distributed randomly versus clumped, bias decreased and precision increased with increasing sample size and increased slightly with increasing core sampler size. Bias and precision were only affected by benthic item density at very low values (500–1,000 items/m2). Detection probability (the probability of capturing ≥ 1 item in a core sample if it is available for sampling) was substantially greater when items were distributed randomly as opposed to clumped. Taking more small diameter core samples was always more time-efficient than taking fewer large diameter samples. We are unable to present a single, optimal sample size, but provide information for researchers and managers to derive optimal sample sizes dependent on their research goals and environmental conditions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Larana, Bruno Casal
2010-01-01
The establishment of the electroweak single top quark production at CDF is experimentally challenging. The small single top signal hidden under large uncertain background processes makes it necessary an excellent understanding of the detector and a detailed study of the processes involved. Moreover, simple counting experiments are not sufficient to extract enough information from the candidate event sample and multivariate analysis techniques are crucial to distinguish signal from background. This thesis presents the world’s most sensitive individual search, together with CDF’s Neural Network analysis, for the combined s- and t-channel single top production. This analysis uses a dataset that correspondsmore » to an integrated luminosity of 3.2fb -1, and is based on a Boosted Decision Tree method that combines information from several input variables to construct a final powerful discriminant, reaching a sensitivity to the combined single top quark production equivalent to 5.2σ. The measured combined single top quark production cross section is 2.1 +0.7 -0.6 pb assuming a top quark mass of 175 GeV/c 2. The probability that this result comes from a background-only fluctuation (p-value) is 0.0002, which corresponds to 3.5σ.« less
Investigation of He-W interactions using DiMES on DIII-D
NASA Astrophysics Data System (ADS)
Doerner, R. P.; Rudakov, D. L.; Chrobak, C. P.; Briesemeister, A. R.; Corr, C.; De Temmerman, G.; Kluth, P.; Lasnier, C. J.; McLean, A. G.; Pace, D. C.; Pitts, R. A.; Schmitz, O.; Thompson, M.; Winters, V.
2016-02-01
Tungsten button samples were exposed to He ELMing H-mode plasma in DIII-D using 2.3 MW of electron cyclotron heating power. Prior to the exposures, the W buttons were exposed to either He, or D, plasma in PISCES-A for 2000 s at surface temperatures of 225-850 °C to create a variety of surfaces (surface blisters, subsurface nano-bubbles, fuzz). Erosion was spectroscopically measured from each DiMES sample, with the exception of the fuzzy W samples which showed almost undetectable WI emission. Post-exposure grazing incidence small angle x-ray scattering surface analysis showed the formation of 1.5 nm diameter He bubbles in the surface of W buttons after only a single DIII-D (3 s, ˜150 ELMs) discharge, similar to the bubble layer resulting from the 2000 s. exposure in PISCES-A. No surface roughening, or damage, was detected on the samples after approximately 600 ELMs with energy density between 0.04-0.1 MJ m-2.
Oh, Chang Seok; Lee, Soong Deok; Kim, Yi-Suk; Shin, Dong Hoon
2015-01-01
Previous study showed that East Asian mtDNA haplogroups, especially those of Koreans, could be successfully assigned by the coupled use of analyses on coding region SNP markers and control region mutation motifs. In this study, we tried to see if the same triple multiplex analysis for coding regions SNPs could be also applicable to ancient samples from East Asia as the complementation for sequence analysis of mtDNA control region. By the study on Joseon skeleton samples, we know that mtDNA haplogroup determined by coding region SNP markers successfully falls within the same haplogroup that sequence analysis on control region can assign. Considering that ancient samples in previous studies make no small number of errors in control region mtDNA sequencing, coding region SNP analysis can be used as good complimentary to the conventional haplogroup determination, especially of archaeological human bone samples buried underground over long periods. PMID:26345190
Schoone, G J; Oskam, L; Kroon, N C; Schallig, H D; Omar, S A
2000-11-01
A quantitative nucleic acid sequence-based amplification (QT-NASBA) assay for the detection of Plasmodium parasites has been developed. Primers and probes were selected on the basis of the sequence of the small-subunit rRNA gene. Quantification was achieved by coamplification of the RNA in the sample with one modified in vitro RNA as a competitor in a single-tube NASBA reaction. Parasite densities ranging from 10 to 10(8) Plasmodium falciparum parasites per ml could be demonstrated and quantified in whole blood. This is approximately 1,000 times more sensitive than conventional microscopy analysis of thick blood smears. Comparison of the parasite densities obtained by microscopy and QT-NASBA with 120 blood samples from Kenyan patients with clinical malaria revealed that for 112 of 120 (93%) of the samples results were within a 1-log difference. QT-NASBA may be especially useful for the detection of low parasite levels in patients with early-stage malaria and for the monitoring of the efficacy of drug treatment.
Miniature sheathed thermocouples for turbine blade temperature measurement
NASA Technical Reports Server (NTRS)
Holanda, R.; Glawe, G. E.; Krause, L. N.
1974-01-01
An investigation was made of sheathed thermocouples for turbine blade temperature measurements. Tests were performed on the Chromel-Alumel sheathed thermocouples with both two-wire and single-wire configurations. Sheath diameters ranged from 0.25 to 0.76 mm, and temperatures ranged from 1080 to 1250 K. Both steady-state and thermal cycling tests were performed for times up to 450 hr. Special-order and commercial-grade thermocouples were tested. The tests showed that special-order single-wire sheathed thermocouples can be obtained that are reliable and accurate with diameters as small as 0.25 mm. However, all samples of 0.25-mm-diameter sheathed commercial-grade two-wire and single-wire thermocouples that were tested showed unacceptable drift rates for long-duration engine testing programs. The drift rates were about 1 percent in 10 hr. A thermocouple drift test is recommended in addition to the normal acceptance tests in order to select reliable miniature sheathed thermocouples for turbine blade applications.
Mojarad, Nassiredin; Krishnan, Madhavi
2012-06-24
Measuring the size and charge of objects suspended in solution, such as dispersions of colloids or macromolecules, is a significant challenge. Measurements based on light scattering are inherently biased to larger entities, such as aggregates in the sample, because the intensity of light scattered by a small object scales as the sixth power of its size. Techniques that rely on the collective migration of species in response to external fields (electric or hydrodynamic, for example) are beset with difficulties including low accuracy and dispersion-limited resolution. Here, we show that the size and charge of single nanoscale objects can be directly measured with high throughput by analysing their thermal motion in an array of electrostatic traps. The approach, which is analogous to Millikan's oil drop experiment, could in future be used to detect molecular binding events with high sensitivity or carry out dynamic single-charge resolved measurements at the solid/liquid interface.
Trifunovic, Luka; Pedrocchi, Fabio L; Hoffman, Silas; Maletinsky, Patrick; Yacoby, Amir; Loss, Daniel
2015-06-01
Magnetic resonance techniques not only provide powerful imaging tools that have revolutionized medicine, but they have a wide spectrum of applications in other fields of science such as biology, chemistry, neuroscience and physics. However, current state-of-the-art magnetometers are unable to detect a single nuclear spin unless the tip-to-sample separation is made sufficiently small. Here, we demonstrate theoretically that by placing a ferromagnetic particle between a nitrogen-vacancy magnetometer and a target spin, the magnetometer sensitivity is improved dramatically. Using materials and techniques that are already experimentally available, our proposed set-up is sensitive enough to detect a single nuclear spin within ten milliseconds of data acquisition at room temperature. The sensitivity is practically unchanged when the ferromagnet surface to the target spin separation is smaller than the ferromagnet lateral dimensions; typically about a tenth of a micrometre. This scheme further benefits when used for nitrogen-vacancy ensemble measurements, enhancing sensitivity by an additional three orders of magnitude.
Microcrystalline silicon growth for heterojunction solar cells
NASA Technical Reports Server (NTRS)
Leung, D. C.; Iles, P. A.; Fang, P. H.
1984-01-01
Microcrystalline Si (m-Si) films with a 1.7eV energy bandgap and crystal size of several hundred A were e-beam evaporated on single crystalline Si (c-Si) to form a heterojunction with the substrate, or a window layer to a single crystalline p-n junction (heteroface structure). The goal was to enhance Voc by such uses of the larger bandgap m-Si, with the intriguing prospect of forming heterostructures with exact lattice match on each layer. The heterojunction structure was affected by interface and shunting problems and the best Voc achieved was only 482mV, well below that of single crystal Si homojunctions. The heteroface structure showed promise for some of the samples with p m-Si/p-n structure (the complementary structure did not show any improvement). Although several runs with different deposition conditions were run, the results were inconsistent. Any Voc enhancement obtained was too small to compensate for the current loss due to the extra absorption and poor carrier transport properties of the m-Si film.
miRNA detection at single-cell resolution using microfluidic LNA flow-FISH
Wu, Meiye; Piccini, Matthew Ernest; Koh, Chung -Yan; ...
2014-08-20
Flow cytometry in combination with fluorescent in situ hybridization (flow-FISH) is a powerful technique that can be utilized to rapidly detect nucleic acids at single-cell resolution without the need for homogenization or nucleic acid extraction. Here, we describe a microfluidic-based method which enables the detection of microRNAs or miRNAs in single intact cells by flow-FISH using locked nucleic acid (LNA)-containing probes. Our method can be applied to all RNA species including mRNA and small noncoding RNA and is suitable for multiplexing with protein immunostaining in the same cell. For demonstration of our method, this chapter details the detection of miR155more » and CD69 protein in PMA and ionomycin-stimulated Jurkat cells. Here, we also include instructions on how to set up a microfluidic chip sample preparation station to prepare cells for imaging and analysis on a commercial flow cytometer or a custom-built micro-flow cytometer.« less
In situ TEM near-field optical probing of nanoscale silicon crystallization.
Xiang, Bin; Hwang, David J; In, Jung Bin; Ryu, Sang-Gil; Yoo, Jae-Hyuck; Dubon, Oscar; Minor, Andrew M; Grigoropoulos, Costas P
2012-05-09
Laser-based processing enables a wide variety of device configurations comprising thin films and nanostructures on sensitive, flexible substrates that are not possible with more traditional thermal annealing schemes. In near-field optical probing, only small regions of a sample are illuminated by the laser beam at any given time. Here we report a new technique that couples the optical near-field of the laser illumination into a transmission electron microscope (TEM) for real-time observations of the laser-materials interactions. We apply this technique to observe the transformation of an amorphous confined Si volume to a single crystal of Si using laser melting. By confinement of the material volume to nanometric dimensions, the entire amorphous precursor is within the laser spot size and transformed into a single crystal. This observation provides a path for laser processing of single-crystal seeds from amorphous precursors, a potentially transformative technique for the fabrication of solar cells and other nanoelectronic devices.
Fransz, Duncan P; Huurnink, Arnold; de Boode, Vosse A; Kingma, Idsart; van Dieën, Jaap H
2015-01-01
Time to stabilization (TTS) is the time it takes for an individual to return to a baseline or stable state following a jump or hop landing. A large variety exists in methods to calculate the TTS. These methods can be described based on four aspects: (1) the input signal used (vertical, anteroposterior, or mediolateral ground reaction force) (2) signal processing (smoothed by sequential averaging, a moving root-mean-square window, or fitting an unbounded third order polynomial), (3) the stable state (threshold), and (4) the definition of when the (processed) signal is considered stable. Furthermore, differences exist with regard to the sample rate, filter settings and trial length. Twenty-five healthy volunteers performed ten 'single leg drop jump landing' trials. For each trial, TTS was calculated according to 18 previously reported methods. Additionally, the effects of sample rate (1000, 500, 200 and 100 samples/s), filter settings (no filter, 40, 15 and 10 Hz), and trial length (20, 14, 10, 7, 5 and 3s) were assessed. The TTS values varied considerably across the calculation methods. The maximum effect of alterations in the processing settings, averaged over calculation methods, were 2.8% (SD 3.3%) for sample rate, 8.8% (SD 7.7%) for filter settings, and 100.5% (SD 100.9%) for trial length. Differences in TTS calculation methods are affected differently by sample rate, filter settings and trial length. The effects of differences in sample rate and filter settings are generally small, while trial length has a large effect on TTS values. Copyright © 2014 Elsevier B.V. All rights reserved.
Moran, Abigail; Buckton, Graham
2009-01-01
The purpose of this research was to investigate the influence of changes in the amorphous state on the crystallization of trehalose. Amorphous trehalose is known to stabilize biomaterials; hence, an understanding of crystallization is vital. Amorphous trehalose, prepared by spray-drying, was exposed to either a single step (0-75%) in relative humidity (RH) or to modulated 0-75-0% RH to cause crystallization. For the single-step experiment, two samples crystallized in a predictable manner to form the dihydrate. One sample, while notionally identical, did not crystallize in the same way and showed a mass loss throughout the time at 75% RH, with a final mass less than that expected for the dihydrate. The idiosyncratic sample was seen to have a starting near infrared (NIR) spectra similar to that exhibited by anhydrous crystalline trehalose, implying that short-range order in the amorphous material (or a small amount of crystalline seed, not detectable using powder X-ray diffraction) caused the sample to fail to form the dihydrate fully when exposed to high RH. The modulated RH study showed that the amorphous material interacted strongly with water; the intensity of the NIR traces was not proportional to mass of water but rather the extent of hydrogen bonding. Subsequent crystallization of this sample clearly was a partial formation of the dihydrate, but with the bulk of the sample then shielded such that it was unable to show significant sorption when exposed to elevated RH. It has been shown that the nature of the amorphous form will alter the way in which samples crystallize. With oscillation in RH, it was possible to further understand the interactions between water and amorphous trehalose.
Kitchen, Robert R; Sabine, Vicky S; Sims, Andrew H; Macaskill, E Jane; Renshaw, Lorna; Thomas, Jeremy S; van Hemert, Jano I; Dixon, J Michael; Bartlett, John M S
2010-02-24
Microarray technology is a popular means of producing whole genome transcriptional profiles, however high cost and scarcity of mRNA has led many studies to be conducted based on the analysis of single samples. We exploit the design of the Illumina platform, specifically multiple arrays on each chip, to evaluate intra-experiment technical variation using repeated hybridisations of universal human reference RNA (UHRR) and duplicate hybridisations of primary breast tumour samples from a clinical study. A clear batch-specific bias was detected in the measured expressions of both the UHRR and clinical samples. This bias was found to persist following standard microarray normalisation techniques. However, when mean-centering or empirical Bayes batch-correction methods (ComBat) were applied to the data, inter-batch variation in the UHRR and clinical samples were greatly reduced. Correlation between replicate UHRR samples improved by two orders of magnitude following batch-correction using ComBat (ranging from 0.9833-0.9991 to 0.9997-0.9999) and increased the consistency of the gene-lists from the duplicate clinical samples, from 11.6% in quantile normalised data to 66.4% in batch-corrected data. The use of UHRR as an inter-batch calibrator provided a small additional benefit when used in conjunction with ComBat, further increasing the agreement between the two gene-lists, up to 74.1%. In the interests of practicalities and cost, these results suggest that single samples can generate reliable data, but only after careful compensation for technical bias in the experiment. We recommend that investigators appreciate the propensity for such variation in the design stages of a microarray experiment and that the use of suitable correction methods become routine during the statistical analysis of the data.
2010-01-01
Background Microarray technology is a popular means of producing whole genome transcriptional profiles, however high cost and scarcity of mRNA has led many studies to be conducted based on the analysis of single samples. We exploit the design of the Illumina platform, specifically multiple arrays on each chip, to evaluate intra-experiment technical variation using repeated hybridisations of universal human reference RNA (UHRR) and duplicate hybridisations of primary breast tumour samples from a clinical study. Results A clear batch-specific bias was detected in the measured expressions of both the UHRR and clinical samples. This bias was found to persist following standard microarray normalisation techniques. However, when mean-centering or empirical Bayes batch-correction methods (ComBat) were applied to the data, inter-batch variation in the UHRR and clinical samples were greatly reduced. Correlation between replicate UHRR samples improved by two orders of magnitude following batch-correction using ComBat (ranging from 0.9833-0.9991 to 0.9997-0.9999) and increased the consistency of the gene-lists from the duplicate clinical samples, from 11.6% in quantile normalised data to 66.4% in batch-corrected data. The use of UHRR as an inter-batch calibrator provided a small additional benefit when used in conjunction with ComBat, further increasing the agreement between the two gene-lists, up to 74.1%. Conclusion In the interests of practicalities and cost, these results suggest that single samples can generate reliable data, but only after careful compensation for technical bias in the experiment. We recommend that investigators appreciate the propensity for such variation in the design stages of a microarray experiment and that the use of suitable correction methods become routine during the statistical analysis of the data. PMID:20181233
Smith, Zachary J.; Wang, Jyh-Chiang E.; Quataert, Sally A.; Berger, Andrew J.
2010-01-01
Integrated Raman and angular-scattering microscopy (IRAM) is a multimodal platform capable of noninvasively probing both the chemistry and morphology of a single cell without prior labeling. Using this system, we are able to detect activation-dependent changes in the Raman and elastic-scattering signals from CD8+ T cells stimulated with either Staphylococcal enterotoxin B (SEB) or phorbol myristate acetate (PMA). In both cases, results obtained from the IRAM instrument correlate well with results obtained from traditional fluorescence-based flow cytometry for paired samples. SEB-mediated activation was distinguished from resting state in CD8+ T cells by an increase in the number and mean size of small (∼500-nm) elastic scatterers as well as a decrease in Raman bands, indicating changes in nuclear content. PMA-mediated activation induced a different profile in CD8+ T cells from SEB, showing a similar increase in small elastic scatterers but a different Raman change, with elevation of cellular protein and lipid bands. These results suggest the potential of this multimodal, label-free optical technique for studying processes in single cells. PMID:20615023
Davis, Bruce M.; Todd, Thomas N.
1998-01-01
Diet and growth of larval lake herring (Coregonus artedi) and lake whitefish (Coregonus clupeaformis) were compared in mesocosm experiments in a small mesotrophic lake in southeastern Michigan. Fish were sampled from single-species and mixed assemblages in 2-m3 cages for 8 weeks during April and May. Both species initially ate mostly cyclopoid copepodites and small cladocerans (Bosmia spp.). Schoener's index of diet overlap showed considerable overlap (70-90%). Lake whitefish ate Daphnia spp. and adult copepods about 2 weeks earlier than did lake herring, perhaps related to their larger mean mouth gape. Lake whitefish were consistently larger than lake herring until the eighth week, especially in the sympatric treatments. Lake whitefish appeared to have a negative effect on the growth of lake herring, as lake herring in mixed-species treatments were smaller and weighed less than lake herring reared in single-species treatments. The diet similarities of lake whitefish and lake herring larvae could make them competitors for food in the Great Lakes. The greater initial size of lake whitefish could allow them to eat larger prey earlier and thereby limit availability of these prey to lake herring at a crucial period of development.
Radics, T; Kiss, C; Tar, I; Márton, I J
2003-02-01
Apical periodontitis is characterized by the presence of immunocompetent cells producing a wide variety of inflammatory mediators. Releasing cytokines with long-range action, such as interleukin-6 (IL-6) and granulocyte-macrophage colony-stimulating factor (GM-CSF), apical periodontitis may induce changes in remote organs of the host. This study quantified the levels of IL-6 and GM-CSF in symptomatic and asymptomatic human periradicular lesions. Lesions were also characterized by size and histologic findings. Tissue samples were homogenized and supernatants were assayed using an enzyme-linked immunosorbent assay (ELISA). Correlations between cytokine levels and characteristic features (as single variables) of the lesions were analysed. There was a trend for higher levels of IL-6 and GM-CSF in symptomatic than in asymptomatic lesions, but the difference was not significant. Levels also tended to be higher in large than in small lesions, in polymorphonuclear (PMN) cell-rich than in PMN cell-poor samples, and in epithelialized than in non-epithelialized lesions. Significantly higher levels of IL-6 (778.1 +/- 220.5 pg/microg) and GM-CSF (363.3 +/- 98.4 pg/microg) were found in samples coincidentally possessing symptomatic and epithelialized features than in asymptomatic, small, PMN cell-poor, non-epithelialized lesions (IL-6: 45.2 +/- 13.1 pg/microg and GM-CSF: 135.1 +/- 26.4 pg/microg). These results suggest that symptomatic lesions containing epithelial cells represent an immunologically active stage of apical periodontitis, whereas asymptomatic, small, PMN cell-poor, non-epithelialized lesions represent healing apical lesions.
Schillaci, Michael A; Schillaci, Mario E
2009-02-01
The use of small sample sizes in human and primate evolutionary research is commonplace. Estimating how well small samples represent the underlying population, however, is not commonplace. Because the accuracy of determinations of taxonomy, phylogeny, and evolutionary process are dependant upon how well the study sample represents the population of interest, characterizing the uncertainty, or potential error, associated with analyses of small sample sizes is essential. We present a method for estimating the probability that the sample mean is within a desired fraction of the standard deviation of the true mean using small (n<10) or very small (n < or = 5) sample sizes. This method can be used by researchers to determine post hoc the probability that their sample is a meaningful approximation of the population parameter. We tested the method using a large craniometric data set commonly used by researchers in the field. Given our results, we suggest that sample estimates of the population mean can be reasonable and meaningful even when based on small, and perhaps even very small, sample sizes.
NASA Astrophysics Data System (ADS)
Osán, J.; Kurunczi, S.; Török, S.; Van Grieken, R.
2002-03-01
A serious heavy metal pollution of the Tisza River occurred on March 10, 2000, arising from a mine-dumping site in Romania. Sediment samples were taken from the main riverbed at six sites in Hungary, on March 16, 2000. The objective of this work was to distinguish the anthropogenic and crustal erosion particles in the river sediment. The samples were investigated using both bulk X-ray fluorescence (XRF) and thin-window electron probe microanalysis (EPMA). For EPMA, a reverse Monte Carlo method calculated the quantitative elemental composition of each single sediment particle. A high abundance of pyrite type particles was observed in some of the samples, indicating the influence of the mine dumps. Backscattered electron images proved that the size of particles with a high atomic number matrix was in the range of 2 μm. In other words the pyrites and the heavy elements form either small particles or are fragments of larger agglomerates. The latter are formed during the flotation process of the mines or get trapped to the natural crustal erosion particles. The XRF analysis of pyrite-rich samples always showed much higher Cu, Zn and Pb concentrations than the rest of the samples, supporting the conclusions of the single-particle EPMA results. In the polluted samples, the concentration of Cu, Zn and Pb reached 0.1, 0.3 and 0.2 wt.%, respectively. As a new approach, the abundance of particle classes obtained from single-particle EPMA and the elemental concentration obtained by XRF were merged into one data set. The dimension of the common data set was reduced by principal component analysis. The first component was determined by the abundance of pyrite and zinc sulfide particles and the concentration of Cu, Zn and Pb. The polluted samples formed a distinct group in the principal component space. The same result was supported by powder diffraction data. These analytical data combined with Earth Observation Techniques can be further used to estimate the quantity of particles originating from mine tailings on a defined river section.
NASA Technical Reports Server (NTRS)
Gentry, Diana; Cynthia Ouandji; Arismendi, Dillon; Guarro, Marcello; Demachkie, Isabella; Crosbie, Ewan; Dadashazar, Hossein; MacDonald, Alex B.; Wang, Zhen; Sorooshian, Armin;
2017-01-01
Just as on the land or in the ocean, atmospheric regions may be more or less hospitable to life. The aerobiosphere, or collection of living things in Earth's atmosphere, is poorly understood due to the small number and ad hoc nature of samples studied. However, we know viable airborne microbes play important roles, such as providing cloud condensation nuclei. Knowing the distribution of such microorganisms and how their activity can alter water, carbon, and other geochemical cycles is key to developing criteria for planetary habitability, particularly for potential habitats with wet atmospheres but little stable surface water. Coastal California has regular, dense fog known to play a major transport role in the local ecosystem. In addition to the significant local (1 km) geographical variation in typical fog, previous studies have found that changes in height above surface of as little as a few meters can yield significant differences in typical concentrations, populations and residence times. No single current sampling platform (ground-based impactors, towers, balloons, aircraft) is capable of accessing all of these regions of interest.A novel passive fog and cloud water sampler, consisting of a lightweight passive impactor suspended from autonomous aerial vehicles (UAVs), is being developed to allow 4D point sampling within a single fog bank, allowing closer study of small-scale (100 m) system dynamics. Fog and cloud droplet water samples from low-altitude aircraft flights in nearby coastal waters were collected and assayed to estimate the required sample volumes, flight times, and sensitivity thresholds of the system under design.125 cloud water samples were collected from 16 flights of the Center for Interdisciplinary Remotely Piloted Aircraft Studies (CIRPAS) instrumented Twin Otter, equipped with a sampling tube collector, occurring between 18 July and 12 August 2016 below 1 km altitude off the central coast. The collector was flushed first with 70 ethanol, then with sterile DI water, between sampling regions. Collected volumes ranged from 100 L to 12 mL. All samples were diluted serially and plated on two different types of agar, nutrient-dense (PCA) and sparse (R-2A). Plates were incubated at room temperature and counted when colonies first appeared and again at 2 weeks.Preliminary results from seven flights are consistent with generally reported colony-forming unit (CFU) values for terrestrial fog water (e.g., [4]). The PCA assay ranged from 400 to 125,000 CFU/mL, R-2A from 700 to 130,000 CFU/mL. PCA and R-2A counts were not significantly different from each other at I^ plus or minus +/- 0.05, although observationally, the R2A plates had more pigmented colonies. CFU counts from the majority of flights were not different from each other in mean at the same level of significance, but about half differed in median, indicating differences in underlying distribution. These results validate the presence of viable microorganisms in coastal California fog at levels that should be easily detectable by our sampling system. The indicated distribution differences underscore the need for small-scale, long-term sampling surveys. Future planned work includes ion chromatography for limiting nutrients, ATP quantification, and qPCR for several microbial classes of interest.
Ultman, J S; Ben-Jebria, A
1991-03-01
We developed a chemiluminescent ozone analyzer and constructed an ozone bolus generator with the eventual goal of using a bolus-response method to measure noninvasively the longitudinal distribution of ozone absorption in human lungs. Because the analyzer will be used to sample gases within a single breath, it must have a sufficiently rapid response to monitor changes in ozone concentration during a four-second breathing period, yet its sampling flow must be small enough that it does not interfere with quiet respiratory flows of 300 mL/sec. Our analyzer, which is based on the chemiluminescent reaction between 2-methyl-2-butene and ozone, has favorable performance characteristics: a 90 percent step-response time of 110 msec; a linear calibration from 0.03 to 10 parts per million (ppm)2 with a sensitivity of 2.3 nA/ppm; a signal-to-noise ratio of 30 evaluated at 0.5 ppm; and a minimum detection limit of 0.017 ppm. At an airflow corresponding to quiet breathing, the ozone generator is capable of producing single boluses with a peak ozone fraction as high as 4 ppm, but containing only 0.35 micrograms of ozone dispersed over a small volume of 19 mL. To test the combination of ozone analyzer and bolus generator, we performed bolus-response experiments at steady airflows of 50 to 200 mL/sec in excised pig and sheep tracheas. In spite of the small surface area available for radial diffusion, we found that 25 to 50 percent of the ozone introduced into the trachea was absorbed. By comparing the mathematical moments of the bolus input and the response curves to the predictions of a diffusion theory, we computed an absorption coefficient (K). The values of K increased with increasing airflow, implying that ozone absorption is limited by diffusion processes in the airway lumen as well as in the surrounding tissue.
Invited Review Small is beautiful: The analysis of nanogram-sized astromaterials
NASA Astrophysics Data System (ADS)
Zolensky, M. E.; Pieters, C.; Clark, B.; Papike, J. J.
2000-01-01
The capability of modern methods to characterize ultra-small samples is well established from analysis of interplanetary dust particles (IDPs), interstellar grains recovered from meteorites, and other materials requiring ultra-sensitive analytical capabilities. Powerful analytical techniques are available that require, under favorable circumstances, single particles of only a few nanograms for entire suites of fairly comprehensive characterizations. A returned sample of >1,000 particles with total mass of just one microgram permits comprehensive quantitative geochemical measurements that are impractical to carry out in situ by flight instruments. The main goal of this paper is to describe the state-of-the-art in microanalysis of astromaterials. Given that we can analyze fantastically small quantities of asteroids and comets, etc., we have to ask ourselves how representative are microscopic samples of bodies that measure a few to many km across? With the Galileo flybys of Gaspra and Ida, it is now recognized that even very small airless bodies have indeed developed a particulate regolith. Acquiring a sample of the bulk regolith, a simple sampling strategy, provides two critical pieces of information about the body. Regolith samples are excellent bulk samples since they normally contain all the key components of the local environment, albeit in particulate form. Furthermore, since this fine fraction dominates remote measurements, regolith samples also provide information about surface alteration processes and are a key link to remote sensing of other bodies. Studies indicate that a statistically significant number of nanogram-sized particles should be able to characterize the regolith of a primitive asteroid, although the presence of larger components within even primitive meteorites (e.g.. Murchison), e.g. chondrules, CAI, large crystal fragments, etc., points out the limitations of using data obtained from nanogram-sized samples to characterize entire primitive asteroids. However, most important asteroidal geological processes have left their mark on the matrix, since this is the finest-grained portion and therefore most sensitive to chemical and physical changes. Thus, the following information can be learned from this fine grain size fraction alone: (1) mineral paragenesis; (2) regolith processes, (3) bulk composition; (4) conditions of thermal and aqueous alteration (if any); (5) relationships to planets, comets, meteorites (via isotopic analyses, including oxygen; (6) abundance of water and hydrated material; (7) abundance of organics; (8) history of volatile mobility, (9) presence and origin of presolar and/or interstellar material. Most of this information can even be obtained from dust samples from bodies for which nanogram-sized samples are not truly representative. Future advances in sensitivity and accuracy of laboratory analytical techniques can be expected to enhance the science value of nano- to microgram sized samples even further. This highlights a key advantage of sample returns - that the most advanced analysis techniques can always be applied in the laboratory, and that well-preserved samples are available for future investigations.
Defects Enable Dark Exciton Photoluminescence in Single-Walled Carbon Nanotubes
Amori, Amanda R.; Rossi, Jamie E.; Landi, Brian J.; ...
2018-01-24
Variable temperature photoluminescence excitation spectroscopy of three (n,m) species of single-walled carbon nanotubes revealed that at resonant S 22 excitation, in addition to allowed excitonic optical transitions, several sidebands that should be forbidden based on selection rules were observed and appeared to have a strong temperature dependence. In particular, we found that a sideband located approximately 130 meV away from the bright S 11 exciton peak relating to the K-momentum dark exciton state, called X 1, decreased in intensity five-fold as the samples were cooled. Direct optical excitation of this dark state is nominally forbidden, thus calling into question howmore » the state is populated, and why it is so prominent in the photoluminescence spectrum. Interestingly, the ratio of the integrated photoluminescence intensities of X 1 to S 11 scales with a Boltzmann factor unrelated to the phonon that is thought to be responsible for depopulating the K-momentum dark exciton state: an in-plane transverse optical phonon, A 1’. Furthermore, photoluminescence spectra from individual (7,5) nanotubes show that only a small fraction exhibit the X 1 feature, with varying oscillator strength, thus suggesting that intrinsic processes such as phonon scattering are not responsible for populating the dark state. Alternatively, we suggest that populating the K-momentum dark exciton state requires scattering from defects, which is consistent with the increased magnitude of the X 1 feature for samples with increased sample purification and processing. Thus, the presence of an X 1 peak in photoluminescence is an extremely sensitive spectroscopic indicator of defects on single-walled carbon nanotubes.« less
Defects Enable Dark Exciton Photoluminescence in Single-Walled Carbon Nanotubes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Amori, Amanda R.; Rossi, Jamie E.; Landi, Brian J.
Variable temperature photoluminescence excitation spectroscopy of three (n,m) species of single-walled carbon nanotubes revealed that at resonant S 22 excitation, in addition to allowed excitonic optical transitions, several sidebands that should be forbidden based on selection rules were observed and appeared to have a strong temperature dependence. In particular, we found that a sideband located approximately 130 meV away from the bright S 11 exciton peak relating to the K-momentum dark exciton state, called X 1, decreased in intensity five-fold as the samples were cooled. Direct optical excitation of this dark state is nominally forbidden, thus calling into question howmore » the state is populated, and why it is so prominent in the photoluminescence spectrum. Interestingly, the ratio of the integrated photoluminescence intensities of X 1 to S 11 scales with a Boltzmann factor unrelated to the phonon that is thought to be responsible for depopulating the K-momentum dark exciton state: an in-plane transverse optical phonon, A 1’. Furthermore, photoluminescence spectra from individual (7,5) nanotubes show that only a small fraction exhibit the X 1 feature, with varying oscillator strength, thus suggesting that intrinsic processes such as phonon scattering are not responsible for populating the dark state. Alternatively, we suggest that populating the K-momentum dark exciton state requires scattering from defects, which is consistent with the increased magnitude of the X 1 feature for samples with increased sample purification and processing. Thus, the presence of an X 1 peak in photoluminescence is an extremely sensitive spectroscopic indicator of defects on single-walled carbon nanotubes.« less
Radiation-driven rotational motion of nanoparticles
Liang, Mengning; Harder, Ross; Robinson, Ian
2018-04-25
Focused synchrotron beams can influence a studied sample via heating, or radiation pressure effects due to intensity gradients. The high angular sensitivity of rotational X-ray tracking (RXT) of crystalline particles via their Bragg reflections can detect extremely small forces such as those caused by field gradients. By tracking the rotational motion of single crystal nanoparticles embedded in a viscous or viscoelastic medium, we observed the effects of heating in a uniform gradient beam and radiation pressure in a Gaussian profile beam. Heating of a few degrees Celsius was measured for 42μm crystals in glycerol and angular velocities of 10 -6rad/smore » due to torques of 10 - 24N∙m were measured for 340nm crystals in a colloidal gel matrix. These results show the ability to quantify small forces using rotation motion of tracer particles.« less
Radiation-driven rotational motion of nanoparticles
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liang, Mengning; Harder, Ross; Robinson, Ian
Focused synchrotron beams can influence a studied sample via heating, or radiation pressure effects due to intensity gradients. The high angular sensitivity of rotational X-ray tracking (RXT) of crystalline particles via their Bragg reflections can detect extremely small forces such as those caused by field gradients. By tracking the rotational motion of single crystal nanoparticles embedded in a viscous or viscoelastic medium, we observed the effects of heating in a uniform gradient beam and radiation pressure in a Gaussian profile beam. Heating of a few degrees Celsius was measured for 42μm crystals in glycerol and angular velocities of 10 -6rad/smore » due to torques of 10 - 24N∙m were measured for 340nm crystals in a colloidal gel matrix. These results show the ability to quantify small forces using rotation motion of tracer particles.« less
Wang, Amy; Robertson, John L; Holladay, Steven D; Tennant, Alan H; Lengi, Andrea J; Ahmed, S Ansar; Huckle, William R; Kligerman, Andrew D
2007-12-01
Urinary bladder transitional epithelium is the main site of bladder cancer, and the use of transitional cells to study carcinogenesis/genotoxicity is recommended over the use of whole bladders. Because the transitional epithelium is only a small fraction of the whole bladder, the alkaline single cell gel electrophoresis assay (Comet assay), which requires only a small number of cells per sample, is especially suitable for measuring DNA damage in transitional cells. However, existed procedures of cell collection did not yield transitional cells with a high purity, and pooling of samples was needed for Comet assay. The goal of this study was to develop an optimized protocol to evaluate DNA damage in the urinary bladder transitional epithelium. This was achieved by an enzymatic stripping method (trypsin-EDTA incubation plus gentle scraping) to selectively harvest transitional cells from rat bladders, and the use of the alkaline Comet assay to detect DNA strand breaks, alkaline labile sites, and DNA-protein crosslinks. Step by step procedures are reported here. Cells collected from a single rat bladder were sufficient for multiple Comet assays. With this new protocol, increases in DNA damage were detected in transitional cells after in vitro exposure to the positive control agents, hydrogen peroxide or formaldehyde. Repair of the induced DNA damage occurred within 4h. This indicated the capacity for DNA repair was maintained in the harvested cells. The new protocol provides a simple and inexpensive method to detect various types of DNA damage and to measure DNA damage repair in urinary bladder transitional cells.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Settens, Charles M.
2015-01-01
Simultaneous migration of planar transistors to FinFET architectures, the introduction of a plurality of materials to ensure suitable electrical characteristics, and the establishment of reliable multiple patterning lithography schemes to pattern sub-10 nm feature sizes imposes formidable challenges to current in-line dimensional metrologies. Because the shape of a FinFET channel cross-section immediately influences the electrical characteristics, the evaluation of 3D device structures requires measurement of parameters beyond traditional critical dimension (CD), including their sidewall angles, top corner rounding and footing, roughness, recesses and undercuts at single nanometer dimensions; thus, metrologies require sub-nm and approaching atomic level measurement uncertainty. Synchrotron criticalmore » dimension small angle X-ray scattering (CD-SAXS) has unique capabilities to non-destructively monitor the cross-section shape of surface structures with single nanometer uncertainty and can perform overlay metrology to sub-nm uncertainty. In this dissertation, we perform a systematic experimental investigation using CD-SAXS metrology on a hierarchy of semiconductor 3D device architectures including, high-aspect-ratio contact holes, H2 annealed Si fins, and a series of grating type samples at multiple points along a FinFET fabrication process increasing in structural intricacy and ending with fully fabricated FinFET. Comparative studies between CD-SAXS metrology and other relevant semiconductor dimensional metrologies, particularly CDSEM, CD-AFM and TEM are used to determine physical limits of CD-SAXS approach for advanced semiconductor samples. CD-SAXS experimental tradeoffs, advice for model-dependent analysis and thoughts on the compatibility with a semiconductor manufacturing environment are discussed.« less
Koblmüller, S; Sefc, K M; Duftner, N; Katongo, C; Tomljanovic, T; Sturmbauer, C
2008-01-01
Some of the diversity of lacustrine cichlid fishes has been ascribed to sympatric divergence, whereas diversification in rivers is generally driven by vicariance and geographic isolation. In the riverine Pseudocrenilabrus philander species complex, several morphologically highly distinct populations are restricted to particular river systems, sinkholes and springs in southern Africa. One of these populations consists of a prevalent yellow morph in sympatry with a less frequent blue morph, and no individuals bear intermediate phenotypes. Genetic variation in microsatellites and AFLP markers was very low in both morphs and one single mtDNA haplotype was fixed in all samples, indicating a very young evolutionary age and small effective population size. Nevertheless, the nuclear markers detected low but significant differentiation between the two morphs. The data suggest recent and perhaps sympatric divergence in the riverine habitat.
Comparison of VRX CT scanners geometries
NASA Astrophysics Data System (ADS)
DiBianca, Frank A.; Melnyk, Roman; Duckworth, Christopher N.; Russ, Stephan; Jordan, Lawrence M.; Laughter, Joseph S.
2001-06-01
A technique called Variable-Resolution X-ray (VRX) detection greatly increases the spatial resolution in computed tomography (CT) and digital radiography (DR) as the field size decreases. The technique is based on a principle called `projective compression' that allows both the resolution element and the sampling distance of a CT detector to scale with the subject or field size. For very large (40 - 50 cm) field sizes, resolution exceeding 2 cy/mm is possible and for very small fields, microscopy is attainable with resolution exceeding 100 cy/mm. This paper compares the benefits obtainable with two different VRX detector geometries: the single-arm geometry and the dual-arm geometry. The analysis is based on Monte Carlo simulations and direct calculations. The results of this study indicate that the dual-arm system appears to have more advantages than the single-arm technique.
A high sensitivity ultralow temperature RF conductance and noise measurement setup.
Parmentier, F D; Mahé, A; Denis, A; Berroir, J-M; Glattli, D C; Plaçais, B; Fève, G
2011-01-01
We report on the realization of a high sensitivity RF noise measurement scheme to study small current fluctuations of mesoscopic systems at milli-Kelvin temperatures. The setup relies on the combination of an interferometric amplification scheme and a quarter-wave impedance transformer, allowing the measurement of noise power spectral densities with gigahertz bandwidth up to five orders of magnitude below the amplifier noise floor. We simultaneously measure the high frequency conductance of the sample by derivating a portion of the signal to a microwave homodyne detection. We describe the principle of the setup, as well as its implementation and calibration. Finally, we show that our setup allows to fully characterize a subnanosecond on-demand single electron source. More generally, its sensitivity and bandwidth make it suitable for applications manipulating single charges at GHz frequencies.
Zhang, Haifeng; Kosinski, J A; Karim, Md Afzalul
2013-05-01
We describe an apparatus for the measurement of acoustic wave propagation under uniaxial loading featuring a special mechanism designed to assure a uniform mechanical load on a cube-shaped sample of piezoelectric material. We demonstrate the utility of the apparatus by determining the effects of stresses on acoustic wave speed, which forms a foundation for the final determination of the third-order elastic constants of langasite and langatate single crystals. The transit time method is used to determine changes in acoustic wave velocity as the loading is varied. In order to minimize error and improve the accuracy of the wave speed measurements, the cross correlation method is used to determine the small changes in the time of flight. Typical experimental results are presented and discussed.
Nardi, Valentina; Pulluqi, Olja; Abramson, Jeremy S; Dal Cin, Paola; Hasserjian, Robert P
2015-06-01
Bone marrow (BM) evaluation is an important part of lymphoma staging, which guides patient management. Although positive staging marrow is defined as morphologically identifiable disease, such samples often also include flow cytometric analysis and conventional karyotyping. Cytogenetic analysis is a labor-intensive and costly procedure and its utility in this setting is uncertain. We retrospectively reviewed pathological reports of 526 staging marrow specimens in which conventional karyotyping had been performed. All samples originated from a single institution from patients with previously untreated Hodgkin and non-Hodgkin lymphomas presenting in an extramedullary site. Cytogenetic analysis revealed clonal abnormalities in only eight marrow samples (1.5%), all of which were positive for lymphoma by morphologic evaluation. Flow cytometry showed a small clonal lymphoid population in three of the 443 morphologically negative marrow samples (0.7%). Conventional karyotyping is rarely positive in lymphoma staging marrow samples and, in our cohort, the BM karyotype did not contribute clinically relevant information in the vast majority of cases. Our findings suggest that karyotyping should not be performed routinely on BM samples taken to stage previously diagnosed extramedullary lymphomas unless there is pathological evidence of BM involvement by lymphoma. © 2015 Wiley Periodicals, Inc.
van Spronsen, F J; van Rijn, M; van Dijk, T; Smit, G P; Reijngoud, D J; Berger, R; Heymans, H S
1993-10-01
To evaluate the adequacy of dietary treatment in patients with phenylketonuria, the monitoring of plasma phenylalanine and tyrosine concentrations is of great importance. The preferable time of blood sampling in relation to the nutritional condition during the day, however, is not known. It was the aim of this study to define guidelines for the timing of blood sampling with a minimal burden for the patient. Plasma concentrations of phenylalanine and tyrosine were measured in nine patients with phenylketonuria who had no clinical evidence of tyrosine deficiency. These values were measured during the day both after a prolonged overnight fast, and before and after breakfast. Phenylalanine showed a small rise during prolonged fasting, while tyrosine decreased slightly. After an individually tailored breakfast, phenylalanine remained stable, while tyrosine showed large fluctuations. It is concluded that the patient's nutritional condition (fasting/postprandial) is not important in the evaluation of the phenylalanine intake. To detect a possible tyrosine deficiency, however, a single blood sample is not sufficient and a combination of a preprandial and postprandial blood sample on the same day is advocated.
Identification and imaging of modern paints using Secondary Ion Mass Spectrometry with MeV ions
NASA Astrophysics Data System (ADS)
Bogdanović Radović, Iva; Siketić, Zdravko; Jembrih-Simbürger, Dubravka; Marković, Nikola; Anghelone, Marta; Stoytschew, Valentin; Jakšić, Milko
2017-09-01
Secondary Ion Mass Spectrometry using MeV ion excitation was applied to analyse modern paint materials containing synthetic organic pigments and binders. It was demonstrated that synthetic organic pigments and binder components with molecular masses in the m/z range from 1 to 1200 could be identified in different paint samples with a high efficiency and in a single measurement. Different ways of mounting of mostly insulating paint samples were tested prior to the analysis in order to achieve the highest possible yield of pigment main molecular ions. As Time-of-Flight mass spectrometer for MeV Secondary Ion Mass Spectrometry is attached to the heavy ion microprobe, molecular imaging on cross-sections of small paint fragments was performed using focused ions. Due to the fact that molecules are extracted from the uppermost layer of the sample and to avoid surface contamination, the paint samples were not embedded in the resin as is usually done when imaging of paint samples using different techniques in the field of cultural heritage.
Study of electrical conductivity and memory switching in the zinc-vanadium-phosphate glasses
NASA Astrophysics Data System (ADS)
Mirzayi, M.; Hekmatshoar, M. H.
2013-07-01
Vanadium zinc phosphate glasses were prepared by the conventional melt quenching technique and effect of V2O5 concentration on d.c. conductivity of prepared samples were investigated. X-ray diffraction patterns confirmed the glassy character of the samples. The d.c. conductivity increased with increase in V2O5 content. Results showed that activation energy has a single value in the investigated range of temperature, which can be explained in accordance with Mott small pollaron hopping model. I-V characteristics at high electric field showed that switching in these glasses was memory type. The threshold field of switching was found to decrease with increase in V2O5 content. Non-linear behavior and switching phenomenon was explained by Pool-Frenkel effect and thermal model.
Sampling large landscapes with small-scale stratification-User's Manual
Bart, Jonathan
2011-01-01
This manual explains procedures for partitioning a large landscape into plots, assigning the plots to strata, and selecting plots in each stratum to be surveyed. These steps are referred to as the "sampling large landscapes (SLL) process." We assume that users of the manual have a moderate knowledge of ArcGIS and Microsoft ® Excel. The manual is written for a single user but in many cases, some steps will be carried out by a biologist designing the survey and some steps will be carried out by a quantitative assistant. Thus, the manual essentially may be passed back and forth between these users. The SLL process primarily has been used to survey birds, and we refer to birds as subjects of the counts. The process, however, could be used to count any objects. ®
NASA Technical Reports Server (NTRS)
Esat, T. M.; Lee, T.; Papanastassiou, D. A.; Wasserburg, G. J.
1978-01-01
The Mg isotopic composition of major and minor mineral phases in the Allende inclusion C1 is reported. The results are analyzed in order to establish whether the Mg isotopic composition is the same in different phases and whether Al-26 is present in a sample which exhibited fractionation and unknown nuclear (FUN) effects on other elements. It is found that a small Mg-26 excess exists in C1 and is correlated with the Al-27/Mg-24 ratio, indicating that Al-26 was present in C1 together with the more general nuclear anomalies. The results also reveal that isotopic homogeneity of Mg in Mg-rich phases in C1 is evident in both bulk samples and single microscopic crystals.
A new spectrometer concept for Mars exploration
NASA Astrophysics Data System (ADS)
Rull, F.; Sansano, A.; Díaz, E.; Colombo, M.; Belenguer, T.; Fernández, M.; Guembe, V.; Canchal, R.; Dávila, B.; Sánchez, A.; Laguna, H.; Ramos, G.; González, C.; Fraga, D.; Gallego, P.; Hutchinson, I.; Ingley, R.; Sánchez, J.; Canora, C. P.; Moral, A. G.; Ibarmia, S.; Prieto, J. A. R.; Manfredi, J. A. R.; Cabo, P.; Díaz, C.; Jiménez, A.; Pla, J.; Margoillés, R.
2011-10-01
The Raman Laser Spectrometer instrument is included in ExoMars program Pasteur payload and it is focused on the Mars samples analytical analysis of the geochemistry content and elemental composition of the observed crushed samples obtained by the Rover. One of the most critical Units of the RLS is the Spectrometer unit (SPU) that performs Raman spectroscopy technique and operates in a very demanding environment (operative temperature: from -40 ºC to 6 ºC) with very restrictive design constraints. It is a very small optical instrument capable to cope with 0.09 nm/pixel of resolution. The selected solution is based on a single transmisive holographic grating. At this stage of the project SPU Team is preparing the Conceptual Design Review that will take place at the end of October 2011.
SEMIPARAMETRIC ADDITIVE RISKS REGRESSION FOR TWO-STAGE DESIGN SURVIVAL STUDIES
Li, Gang; Wu, Tong Tong
2011-01-01
In this article we study a semiparametric additive risks model (McKeague and Sasieni (1994)) for two-stage design survival data where accurate information is available only on second stage subjects, a subset of the first stage study. We derive two-stage estimators by combining data from both stages. Large sample inferences are developed. As a by-product, we also obtain asymptotic properties of the single stage estimators of McKeague and Sasieni (1994) when the semiparametric additive risks model is misspecified. The proposed two-stage estimators are shown to be asymptotically more efficient than the second stage estimators. They also demonstrate smaller bias and variance for finite samples. The developed methods are illustrated using small intestine cancer data from the SEER (Surveillance, Epidemiology, and End Results) Program. PMID:21931467
Pinched-flow hydrodynamic stretching of single-cells.
Dudani, Jaideep S; Gossett, Daniel R; Tse, Henry T K; Di Carlo, Dino
2013-09-21
Reorganization of cytoskeletal networks, condensation and decondensation of chromatin, and other whole cell structural changes often accompany changes in cell state and can reflect underlying disease processes. As such, the observable mechanical properties, or mechanophenotype, which is closely linked to intracellular architecture, can be a useful label-free biomarker of disease. In order to make use of this biomarker, a tool to measure cell mechanical properties should accurately characterize clinical specimens that consist of heterogeneous cell populations or contain small diseased subpopulations. Because of the heterogeneity and potential for rare populations in clinical samples, single-cell, high-throughput assays are ideally suited. Hydrodynamic stretching has recently emerged as a powerful method for carrying out mechanical phenotyping. Importantly, this method operates independently of molecular probes, reducing cost and sample preparation time, and yields information-rich signatures of cell populations through significant image analysis automation, promoting more widespread adoption. In this work, we present an alternative mode of hydrodynamic stretching where inertially-focused cells are squeezed in flow by perpendicular high-speed pinch flows that are extracted from the single inputted cell suspension. The pinched-flow stretching method reveals expected differences in cell deformability in two model systems. Furthermore, hydraulic circuit design is used to tune stretching forces and carry out multiple stretching modes (pinched-flow and extensional) in the same microfluidic channel with a single fluid input. The ability to create a self-sheathing flow from a single input solution should have general utility for other cytometry systems and the pinched-flow design enables an order of magnitude higher throughput (65,000 cells s(-1)) compared to our previously reported deformability cytometry method, which will be especially useful for identification of rare cell populations in clinical body fluids in the future.
Pohl, Lydia; Kölbl, Angelika; Werner, Florian; Mueller, Carsten W; Höschen, Carmen; Häusler, Werner; Kögel-Knabner, Ingrid
2018-04-30
Aluminium (Al)-substituted goethite is ubiquitous in soils and sediments. The extent of Al-substitution affects the physicochemical properties of the mineral and influences its macroscale properties. Bulk analysis only provides total Al/Fe ratios without providing information with respect to the Al-substitution of single minerals. Here, we demonstrate that nanoscale secondary ion mass spectrometry (NanoSIMS) enables the precise determination of Al-content in single minerals, while simultaneously visualising the variation of the Al/Fe ratio. Al-substituted goethite samples were synthesized with increasing Al concentrations of 0.1, 3, and 7 % and analysed by NanoSIMS in combination with established bulk spectroscopic methods (XRD, FTIR, Mössbauer spectroscopy). The high spatial resolution (50-150 nm) of NanoSIMS is accompanied by a high number of single-point measurements. We statistically evaluated the Al/Fe ratios derived from NanoSIMS, while maintaining the spatial information and reassigning it to its original localization. XRD analyses confirmed increasing concentration of incorporated Al within the goethite structure. Mössbauer spectroscopy revealed 11 % of the goethite samples generated at high Al concentrations consisted of hematite. The NanoSIMS data show that the Al/Fe ratios are in agreement with bulk data derived from total digestion and demonstrated small spatial variability between single-point measurements. More advantageously, statistical analysis and reassignment of single-point measurements allowed us to identify distinct spots with significantly higher or lower Al/Fe ratios. NanoSIMS measurements confirmed the capacity to produce images, which indicated the uniform increase in Al-concentrations in goethite. Using a combination of statistical analysis with information from complementary spectroscopic techniques (XRD, FTIR and Mössbauer spectroscopy) we were further able to reveal spots with lower Al/Fe ratios as hematite. Copyright © 2018 John Wiley & Sons, Ltd.
Porter, Charlotte A; Bradley, Kevin M; McGowan, Daniel R
2018-05-01
The aim of this study was to verify, with a large dataset of 1394 Cr-EDTA glomerular filtration rate (GFR) studies, the equivalence of slope-intercept and single-sample GFR. Raw data from 1394 patient studies were used to calculate four-sample slope-intercept GFR in addition to four individual single-sample GFR values (blood samples taken at 90, 150, 210 and 270 min after injection). The percentage differences between the four-sample slope-intercept and each of the single-sample GFR values were calculated, to identify the optimum single-sample time point. Having identified the optimum time point, the percentage difference between the slope-intercept and optimal single-sample GFR was calculated across a range of GFR values to investigate whether there was a GFR value below which the two methodologies cannot be considered equivalent. It was found that the lowest percentage difference between slope-intercept and single-sample GFR was for the third blood sample, taken at 210 min after injection. The median percentage difference was 2.5% and only 6.9% of patient studies had a percentage difference greater than 10%. Above a GFR value of 30 ml/min/1.73 m, the median percentage difference between the slope-intercept and optimal single-sample GFR values was below 10%, and so it was concluded that, above this value, the two techniques are sufficiently equivalent. This study supports the recommendation of performing single-sample GFR measurements for GFRs greater than 30 ml/min/1.73 m.
Small fibre neuropathy in mitochondrial diseases explored with sudoscan.
Luigetti, Marco; Primiano, Guido; Cuccagna, Cristina; Bernardo, Daniela; Sauchelli, Donato; Vollono, Catello; Servidei, Serenella
2018-06-01
Polyneuropathy in mitochondrial diseases (MDs) is relatively common and widely investigated, but few data are instead reported about small fibres involvement. In order to investigate the involvement of small fibres in MDs we performed extensive neurophysiological test (nerve conduction studies; sympathetic skin response; sudoscan) in 27 patients with genetic diagnosis of MD (7 m.3243A > G; 4 m.8344A > G; 9 single mtDNA deletion; 7 multiple mtDNA deletions). NCS showed a polyneuropathy in 11/27 cases (41%). The incidence was very high in POLG1 (100%), m.8344A > G (75%) and m.3243A > G (43%), while only 11% of patients with single deletion had evidence of large fibres involvement. Sympathetic skin response was abnormal only in three patients (one progressive external ophthalmoplegia with single mtDNA deletion; one patient with m.3243A > G mutation; one patient with POLG1 mutation). Sudoscan revealed the presence of an autonomic small fibres dysfunction in 9/27 cases (33%), most of them (7/9) carrying a single mtDNA deletion. Sudoscan data were also confirmed in a sub-group of patients by laser evoked potentials study. Considering only patients with single mtDNA deletion 7/9 (78%) showed abnormal results at sudoscan. Small fibre neuropathy is another feature to investigate in mitochondrial diseases and seems specifically associated with the presence of single mtDNA deletion. The correct identification through specific neurophysiological tests of small fibres involvement in MDs represents another tile in this challenging diagnosis. Copyright © 2018 International Federation of Clinical Neurophysiology. Published by Elsevier B.V. All rights reserved.
Using large volume samplers for the monitoring of particle bound micro pollutants in rivers
NASA Astrophysics Data System (ADS)
Kittlaus, Steffen; Fuchs, Stephan
2015-04-01
The requirements of the WFD as well as substance emission modelling at the river basin scale require stable monitoring data for micro pollutants. The monitoring concepts applied by the local authorities as well as by many scientists use single sampling techniques. Samples from water bodies are usually taken in volumes of about one litre and depending on predetermined time steps or through discharge thresholds. For predominantly particle bound micro pollutants the small sample size of about one litre results in a very small amount of suspended particles. To measure micro pollutant concentrations in these samples is demanding and results in a high uncertainty of the measured concentrations, if the concentration is above the detection limit in the first place. In many monitoring programs most of the measured values were below the detection limit. This results in a high uncertainty if river loads were calculated from these data sets. The authors propose a different approach to gain stable concentration values for particle bound micro pollutants from river monitoring: A mixed sample of about 1000 L was pumped in a tank with a dirty-water pump. The sampling usually is done discharge dependant by using a gauge signal as input for the control unit. After the discharge event is over or the tank is fully filled, the suspended solids settle in the tank for 2 days. After this time a clear separation of water and solids can be shown. A sample (1 L) from the water phase and the total mass of the settled solids (about 10 L) are taken to the laboratory for analysis. While the micro pollutants can't hardly be detected in the water phase, the signal from the sediment is high above the detection limit, thus certain and very stable. From the pollutant concentration in the solid phase and the total tank volume the initial pollutant concentration in the sample can be calculated. If the concentration in the water phase is detectable, it can be used to correct the total load. This relatively low cost approach (less costs for analysis because of small sample number) allows to quantify the pollutant load, to derive dissolved-solid partition coefficients and to quantify the pollutant load in different particle size classes.
Anti-Brownian ELectrokinetic (ABEL) Trapping of Single High Density Lipoprotein (HDL) Particles
NASA Astrophysics Data System (ADS)
Bockenhauer, Samuel; Furstenberg, Alexandre; Wang, Quan; Devree, Brian; Jie Yao, Xiao; Bokoch, Michael; Kobilka, Brian; Sunahara, Roger; Moerner, W. E.
2010-03-01
The ABEL trap is a novel device for trapping single biomolecules in solution for extended observation. The trap estimates the position of a fluorescently-labeled object as small as ˜10 nm in solution and then applies a feedback electrokinetic drift every 20 us to trap the object by canceling its Brownian motion. We use the ABEL trap to study HDL particles at the single-copy level. HDL particles, essential in regulation of ``good'' cholesterol in humans, comprise a small (˜10 nm) lipid bilayer disc bounded by a belt of apolipoproteins. By engineering HDL particles with single fluorescent donor/acceptor probes and varying lipid compositions, we are working to study lipid diffusion on small length scales. We also use HDL particles as hosts for single transmembrane receptors, which should enable study of receptor conformational dynamics on long timescales.
Detection of small number of Giardia in biological materials prepared from stray dogs.
Esmailikia, Leila; Ebrahimzade, Elahe; Shayan, Parviz; Amininia, Narges
2017-12-20
Giardia lamblia is an intestinal protozoa with intermittent and low shedding especially in dogs, and the detection of Giardia is accompanied with problems such as sampling and diagnostic method. The objective of this study was to detection of Giardia in biological materials with low number of parasite using parasitological and molecular methods, and also to determine whether the examined stray dogs harbor known zoonotic genotype of Giardia. For this aim 85 fecal and duodenal samples were studied from which 1 was positive by Trichrome staining of stool, 4 were positive by staining of duodenal samples. The nested PCR analysis with primers derived from 18 SrRNA showed that the specific PCR product could be amplified in 4 stool and 4 duodenal samples. All positive samples in staining analysis were also positive in nested PCR. No amplification could be observed by nested PCR with primers derived from β giardin gene due to the single copy of gene. Interestingly, the extracted DNA from old fixed stained Giardia positive smears could be also amplified with primers derived from 18SrRNA gene. The sequence analysis of nested PCR products showed that they belong to the genotype D. In conclusion, it is to denote that the Trichrome or Giemsa methods were not suitable for the detection of small number of this parasite in stool and the nested PCR with primers derived from 18S rRNA gene can replace the traditional methods successfully. For detection of Giardia in stool, primers derived from β giardin will not be recommended.
Rakotonanahary, Rado J L; Harrison, Alan; Maina, Alice N; Jiang, Ju; Richards, Allen L; Rajerison, Minoarisoa; Telfer, Sandra
2017-03-04
Rickettsiae are obligate intracellular bacteria responsible for many febrile syndromes around the world, including in sub-Saharan Africa. Vectors of these pathogens include ticks, lice, mites and fleas. In order to assess exposure to flea-associated Rickettsia species in Madagascar, human and small mammal samples from an urban and a rural area, and their associated fleas were tested. Anti-typhus group (TGR)- and anti-spotted fever group rickettsiae (SFGR)-specific IgG were detected in 24 (39%) and 21 (34%) of 62 human serum samples, respectively, using indirect ELISAs, with six individuals seropositive for both. Only two (2%) Rattus rattus out of 86 small mammals presented antibodies against TGR. Out of 117 fleas collected from small mammals, Rickettsia typhi, a TGR, was detected in 26 Xenopsylla cheopis (24%) collected from rodents of an urban area (n = 107), while two of these urban X. cheopis (2%) were positive for Rickettsia felis, a SFGR. R. felis DNA was also detected in eight (31%) out of 26 Pulex irritans fleas. The general population in Madagascar are exposed to rickettsiae, and two flea-associated Rickettsia pathogens, R. typhi and R. felis, are present near or in homes. Although our results are from a single district, they demonstrate that rickettsiae should be considered as potential agents of undifferentiated fever in Madagascar.
Holmes, Tyson H; He, Xiao-Song
2016-10-01
Small, wide data sets are commonplace in human immunophenotyping research. As defined here, a small, wide data set is constructed by sampling a small to modest quantity n,1
Holmes, Tyson H.; He, Xiao-Song
2016-01-01
Small, wide data sets are commonplace in human immunophenotyping research. As defined here, a small, wide data set is constructed by sampling a small to modest quantity n, 1 < n < 50, of human participants for the purpose of estimating many parameters p, such that n < p < 1,000. We offer a set of prescriptions that are designed to facilitate low-variance (i.e. stable), low-bias, interpretive regression modeling of small, wide data sets. These prescriptions are distinctive in their especially heavy emphasis on minimizing use of out-of-sample information for conducting statistical inference. That allows the working immunologist to proceed without being encumbered by imposed and often untestable statistical assumptions. Problems of unmeasured confounders, confidence-interval coverage, feature selection, and shrinkage/denoising are defined clearly and treated in detail. We propose an extension of an existing nonparametric technique for improved small-sample confidence-interval tail coverage from the univariate case (single immune feature) to the multivariate (many, possibly correlated immune features). An important role for derived features in the immunological interpretation of regression analyses is stressed. Areas of further research are discussed. Presented principles and methods are illustrated through application to a small, wide data set of adults spanning a wide range in ages and multiple immunophenotypes that were assayed before and after immunization with inactivated influenza vaccine (IIV). Our regression modeling prescriptions identify some potentially important topics for future immunological research. 1) Immunologists may wish to distinguish age-related differences in immune features from changes in immune features caused by aging. 2) A form of the bootstrap that employs linear extrapolation may prove to be an invaluable analytic tool because it allows the working immunologist to obtain accurate estimates of the stability of immune parameter estimates with a bare minimum of imposed assumptions. 3) Liberal inclusion of immune features in phenotyping panels can facilitate accurate separation of biological signal of interest from noise. In addition, through a combination of denoising and potentially improved confidence interval coverage, we identify some candidate immune correlates (frequency of cell subset and concentration of cytokine) with B cell response as measured by quantity of IIV-specific IgA antibody-secreting cells and quantity of IIV-specific IgG antibody-secreting cells. PMID:27196789
NASA Astrophysics Data System (ADS)
Gao, Yuan; Ma, Jiayi; Yuille, Alan L.
2017-05-01
This paper addresses the problem of face recognition when there is only few, or even only a single, labeled examples of the face that we wish to recognize. Moreover, these examples are typically corrupted by nuisance variables, both linear (i.e., additive nuisance variables such as bad lighting, wearing of glasses) and non-linear (i.e., non-additive pixel-wise nuisance variables such as expression changes). The small number of labeled examples means that it is hard to remove these nuisance variables between the training and testing faces to obtain good recognition performance. To address the problem we propose a method called Semi-Supervised Sparse Representation based Classification (S$^3$RC). This is based on recent work on sparsity where faces are represented in terms of two dictionaries: a gallery dictionary consisting of one or more examples of each person, and a variation dictionary representing linear nuisance variables (e.g., different lighting conditions, different glasses). The main idea is that (i) we use the variation dictionary to characterize the linear nuisance variables via the sparsity framework, then (ii) prototype face images are estimated as a gallery dictionary via a Gaussian Mixture Model (GMM), with mixed labeled and unlabeled samples in a semi-supervised manner, to deal with the non-linear nuisance variations between labeled and unlabeled samples. We have done experiments with insufficient labeled samples, even when there is only a single labeled sample per person. Our results on the AR, Multi-PIE, CAS-PEAL, and LFW databases demonstrate that the proposed method is able to deliver significantly improved performance over existing methods.
Theory of using magnetic deflections to combine charged particle beams
DOE Office of Scientific and Technical Information (OSTI.GOV)
Steckbeck, Mackenzie K.; Doyle, Barney Lee
2014-09-01
Several radiation effects projects in the Ion Beam Lab (IBL) have recently required two disparate charged particle beams to simultaneously strike a single sample through a single port of the target chamber. Because these beams have vastly different mass–energy products (MEP), the low-MEP beam requires a large angle of deflection toward the sample by a bending electromagnet. A second electromagnet located further upstream provides a means to compensate for the small angle deflection experienced by the high-MEP beam during its path through the bending magnet. This paper derives the equations used to select the magnetic fields required by these twomore » magnets to achieve uniting both beams at the target sample. A simple result was obtained when the separation of the two magnets was equivalent to the distance from the bending magnet to the sample, and the equation is given by: B s= 1/2(r c/r s) B c, where B s and B c are the magnetic fields in the steering and bending magnet and r c/r s is the ratio of the radii of the bending magnet to that of the steering magnet. This result is not dependent upon the parameters of the high MEP beam, i.e. energy, mass, charge state. Therefore, once the field of the bending magnet is set for the low-MEP beam, and the field in the steering magnet is set as indicted in the equation, the trajectory path of any high-MEP beam will be directed into the sample.« less
Specific heat of Nb{sub 3}Sn: The case for a single gap
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jo, Y. J., E-mail: jophy@knu.ac.kr; Zhou, Jian; Sung, Zu Hawn
2014-10-01
The important influence of multiple gaps in the superconductivity of MgB{sub 2} and Fe-based compounds, especially because of the possibility that manipulation of a second gap can significantly raise the upper critical field H{sub c2}, has refocused attention on Nb{sub 3}Sn because anomalies in both specific heat and point-contact tunneling studies have led to the proposal that Nb{sub 3}Sn is also a two-gap superconductor. Here, we search for evidence of the second gap in a careful study of the influence of the homogenization temperature on the sample uniformity. We show that it is very difficult to fabricate samples that aremore » both homogeneous and stoichiometric. We find so-called “second-gap” anomalies disappear only after high temperature and long-term annealing. Such a well-annealed sample shows only a strong, electron-phonon-coupled, single-gap behavior. In contrast, samples reacted and annealed at lower temperatures, as in the earlier two-gap studies, show small chemical composition variations of the A15 phase. We propose that the second gap sightings are actually due to variation of T{sub c} within very difficult-to-fully homogenize samples. A curiosity of the A15 Nb{sub 3}Sn phase is that almost any mixture of Nb and Sn tries to form a stoichiometric A15 composition, but the residue of course contains off-stoichiometric A15, Nb, and other phases when the Nb:Sn ratio departs from the true 3:1 stoichiometry.« less
Monte Carlo simulation of induction time and metastable zone width; stochastic or deterministic?
NASA Astrophysics Data System (ADS)
Kubota, Noriaki
2018-03-01
The induction time and metastable zone width (MSZW) measured for small samples (say 1 mL or less) both scatter widely. Thus, these two are observed as stochastic quantities. Whereas, for large samples (say 1000 mL or more), the induction time and MSZW are observed as deterministic quantities. The reason for such experimental differences is investigated with Monte Carlo simulation. In the simulation, the time (under isothermal condition) and supercooling (under polythermal condition) at which a first single crystal is detected are defined as the induction time t and the MSZW ΔT for small samples, respectively. The number of crystals just at the moment of t and ΔT is unity. A first crystal emerges at random due to the intrinsic nature of nucleation, accordingly t and ΔT become stochastic. For large samples, the time and supercooling at which the number density of crystals N/V reaches a detector sensitivity (N/V)det are defined as t and ΔT for isothermal and polythermal conditions, respectively. The points of t and ΔT are those of which a large number of crystals have accumulated. Consequently, t and ΔT become deterministic according to the law of large numbers. Whether t and ΔT may stochastic or deterministic in actual experiments should not be attributed to change in nucleation mechanisms in molecular level. It could be just a problem caused by differences in the experimental definition of t and ΔT.
Zanoni, R G; Bugnon, Ph; Deranleau, E; Nguyen, T M V; Brügger, D
2010-12-01
Data of 13'469 blood samples from 10'999 dogs and 2'470 cats tested for rabies neutralizing antibodies within the framework of pet travel schemes were analysed for single and combined factors influencing antibody titres and failures. The time span between vaccination and drawing the blood sample was confirmed as a major source of failure in dogs with a proportion of 23 % at 4 months after primary vaccination (single dose). Failures in dogs and cats (titre < 0.5 IU) were significantly reduced after double primary vaccination (2 doses within 7 - 10 days), although failures reached comparable levels in dogs as early as 6 months after vaccination. In contrast, failure after vaccination was generally below 5 % in dogs and absent in cats after a booster applied at earliest 12 months after single primary vaccination. Statistically significant differences between the failures of the vaccine brands «Rabisin» (1.5 %), «Defensor» (6.7 %), «Nobivac Rabies» (11.0 %) and «Rabdomun» (18.2 %) were found in dogs but also between the titres induced in cats. Significant differences were found between different dog breeds with some small breeds showing a significantly higher responsiveness. Taken together, a new regimen for rabies vaccination consisting of double primary vaccination with a short interval of 7 - 10 days and a one-year booster appears to be highly recommended for dogs and cats.
NASA Astrophysics Data System (ADS)
Pereverzev, Sergey
2017-02-01
Many life-relevant interaction energies are in IR range, and it is reasonable to believe that some biochemical reactions inside cells can results in emission of IR photons. Cells can use this emission for non-chemical and non-electrical signaling. Detecting weak infrared radiation from live cells is complicated because of strong thermal radiation background and absorption of radiation by tissues. A microfluidic device with live cells inside a vacuum cryogenic environment should suppress this background, and thereby permit observation of live cell auto-luminescence or signaling in the IR regime. One can make IR-transparent windows not emitting in this range, so only the cell and a small amount of liquid around it will emit infrared radiation. Currently mid-IR spectroscopy of single cells requires the use of a synchrotron source to measure absorption or reflection spectra. Decreasing of thermal radiation background will allow absorption and reflection spectroscopy of cells without using synchrotron light. Moreover, cell auto-luminescence can be directly measured. The complete absence of thermal background radiation for cryogenically cooled samples allows the use IR photon-sensitive detectors and obtaining single molecule sensitivity in IR photo-luminescence measurements. Due to low photon energies, photo-luminescence measurements will be non-distractive for pressures samples. The technique described here is based upon US patent 9366574.
NASA Astrophysics Data System (ADS)
Mokrý, Pavel; Psota, Pavel; Steiger, Kateřina; Václavík, Jan; Vápenka, David; Doleček, Roman; Vojtíšek, Petr; Sládek, Juraj; Lédl, Vít.
2016-11-01
We report on the development and implementation of the digital holographic tomography for the three-dimensio- nal (3D) observations of the domain patterns in the ferroelectric single crystals. Ferroelectric materials represent a group of materials, whose macroscopic dielectric, electromechanical, and elastic properties are greatly in uenced by the presence of domain patterns. Understanding the role of domain patterns on the aforementioned properties require the experimental techniques, which allow the precise 3D measurements of the spatial distribution of ferroelectric domains in the single crystal. Unfortunately, such techniques are rather limited at this time. The most frequently used piezoelectric atomic force microscopy allows 2D observations on the ferroelectric sample surface. Optical methods based on the birefringence measurements provide parameters of the domain patterns averaged over the sample volume. In this paper, we analyze the possibility that the spatial distribution of the ferroelectric domains can be obtained by means of the measurement of the wavefront deformation of the transmitted optical wave. We demonstrate that the spatial distribution of the ferroelectric domains can be determined by means of the measurement of the spatial distribution of the refractive index. Finally, it is demonstrated that the measurements of wavefront deformations generated in ferroelectric polydomain systems with small variations of the refractive index provide data, which can be further processed by means of the conventional tomographic methods.
Wang, Yijia; Zeinhom, Mohamed M A; Yang, Mingming; Sun, Rongrong; Wang, Shengfu; Smith, Jordan N; Timchalk, Charles; Li, Lei; Lin, Yuehe; Du, Dan
2017-09-05
Onsite rapid detection of herbicides and herbicide residuals in environmental and biological specimens are important for agriculture, environmental concerns, food safety, and health care. The traditional method for herbicide detection requires expensive laboratory equipment and a long turnaround time. In this work, we developed a single-stripe microliter plate smartphone-based colorimetric device for rapid and low-cost in-field tests. This portable smartphone platform is capable of screening eight samples in a single-stripe microplate. The device combined the advantages of small size (50 × 100 × 160 mm 3 ) and low cost ($10). The platform was calibrated by using two different dye solutions, i.e. methyl blue (MB) and rhodamine B, for the red and green channels. The results showed good correlation with results attained from a traditional laboratory reader. We demonstrated the application of this platform for detection of the herbicide 2,4-dichlorophenoxyacetic acid in the range of 1 to 80 ppb. Spiked samples of tap water, rat serum, plasma, and human serum were tested by our device. Recoveries obtained varied from 95.6% to 105.2% for all of the spiked samples using the microplate reader and from 93.7% to 106.9% for all of the samples using the smartphone device. This work validated that the smartphone optical-sensing platform is comparable to the commercial microplate reader; it is eligible for onsite, rapid, and low-cost detection of herbicides for environmental evaluation and biological monitoring.
Microfluidic point-of-care blood panel based on a novel technique: Reversible electroosmotic flow
Mohammadi, Mahdi; Madadi, Hojjat; Casals-Terré, Jasmina
2015-01-01
A wide range of diseases and conditions are monitored or diagnosed from blood plasma, but the ability to analyze a whole blood sample with the requirements for a point-of-care device, such as robustness, user-friendliness, and simple handling, remains unmet. Microfluidics technology offers the possibility not only to work fresh thumb-pricked whole blood but also to maximize the amount of the obtained plasma from the initial sample and therefore the possibility to implement multiple tests in a single cartridge. The microfluidic design presented in this paper is a combination of cross-flow filtration with a reversible electroosmotic flow that prevents clogging at the filter entrance and maximizes the amount of separated plasma. The main advantage of this design is its efficiency, since from a small amount of sample (a single droplet ∼10 μl) almost 10% of this (approx 1 μl) is extracted and collected with high purity (more than 99%) in a reasonable time (5–8 min). To validate the quality and quantity of the separated plasma and to show its potential as a clinical tool, the microfluidic chip has been combined with lateral flow immunochromatography technology to perform a qualitative detection of the thyroid-stimulating hormone and a blood panel for measuring cardiac Troponin and Creatine Kinase MB. The results from the microfluidic system are comparable to previous commercial lateral flow assays that required more sample for implementing fewer tests. PMID:26396660
Miniature Cryogenic Valves for a Titan Lake Sampling System
NASA Technical Reports Server (NTRS)
Sherrit, Stewart; Zimmerman, Wayne; Takano, Nobuyuki; Avellar, Louisa
2014-01-01
The Cassini mission has revealed Titan to be one of the most Earthlike worlds in the Solar System complete with many of the same surface features including lakes, river channels, basins, and dunes. But unlike Earth, the materials and fluids on Titan are composed of cryogenic organic compounds with lakes of liquid methane and ethane. One of the potential mission concepts to explore Titan is to land a floating platform on one of the Titan Lakes and determine the local lake chemistry. In order to accomplish this within the expected mass volume and power budgets there is a need to pursue the development for a low power lightweight cryogenic valves which can be used along with vacuum lines to sample lake liquid and to distribute to various instruments aboard the Lander. To meet this need we have initiated the development of low power cryogenic valves and actuators based on a single crystal piezoelectric flextensional stacks produced by TRS Ceramics Inc. Since the origin of such high electromechanical properties of Relaxor-PT single crystals is due to the polarization rotation effect, (i.e., intrinsic contributions), the strain per volt decrease at cryogenic temperatures is much lower than in standard Lead Zirconate Titanate (PZT) ceramics. This makes them promising candidates for cryogenic actuators with regards to the stroke for a given voltage. This paper will present our Titan Lake Sampling and Sample Handling system design and the development of small cryogenic piezoelectric valves developed to meet the system specifications.
Tang, Sheng; Lee, Hian Kee
2016-05-15
A novel syringe needle-based sampling approach coupled with liquid-phase extraction (NBS-LPE) was developed and applied to the extraction of l-ascorbic acid (AsA) in apple. In NBS-LPE, only a small amount of apple flesh (ca. 10mg) was sampled directly using a syringe needle and placed in a glass insert for liquid extraction of AsA by 80 μL oxalic acid-acetic acid. The extract was then directly analyzed by liquid chromatography. This new procedure is simple, convenient, almost organic solvent free, and causes far less damage to the fruit. To demonstrate the applicability of NBS-LPE, AsA levels at different sampling points in a single apple were determined to reveal the spatial distribution of the analyte in a three-dimensional model. The results also showed that this method had good sensitivity (limit of detection of 0.0097 mg/100g; limit of quantification of 0.0323 mg/100g), acceptable reproducibility (relative standard deviation of 5.01% (n=6)), a wide linear range of between 0.05 and 50mg/100g, and good linearity (r(2)=0.9921). This interesting extraction technique and modeling approach can be used to measure and monitor a wide range of compounds in various parts of different soft-matrix fruits and vegetables, including single specimens. Copyright © 2015 Elsevier Ltd. All rights reserved.
Kipper, Karin; Barker, Charlotte I S; Standing, Joseph F; Sharland, Mike; Johnston, Atholl
2018-01-01
Penicillins are widely used to treat infections in children; however, the evidence is continuing to evolve in defining the optimal dosing. Modern pediatric pharmacokinetic study protocols frequently favor opportunistic, "scavenged" sampling. This study aimed to develop a small-volume single assay for five major penicillins and to assess the influence of sample degradation on inferences made using pharmacokinetic modeling, to investigate the suitability of scavenged sampling strategies. Using a rapid ultrahigh-performance liquid chromatographic-tandem mass spectrometric method, an assay for five penicillins (amoxicillin, ampicillin, benzylpenicillin, piperacillin, and flucloxacillin) in blood plasma was developed and validated. Penicillin stabilities were evaluated under different conditions. Using these data, the impact of drug degradation on inferences made during pharmacokinetic modeling was evaluated. All evaluated penicillins indicated good stability at room temperature (23 ± 2°C) over 1 h, remaining in the range of 98 to 103% of the original concentration. More-rapid analyte degradation had already occurred after 4 h, with stability ranging from 68% to 99%. Stability over longer periods declined: degradation of up to 60% was observed with delayed sample processing of up to 24 h. Modeling showed that analyte degradation can lead to a 30% and 28% bias in clearance and volume of distribution, respectively, and falsely show nonlinearity in clearance. Five common penicillins can now be measured in a single low-volume blood sample. Beta-lactam chemical instability in plasma can cause misleading pharmacokinetic modeling results, which could impact upon model-based dosing recommendations and the forthcoming era of beta-lactam therapeutic drug monitoring. Copyright © 2017 American Society for Microbiology.
Sidler, Dominik; Cristòfol-Clough, Michael; Riniker, Sereina
2017-06-13
Replica-exchange enveloping distribution sampling (RE-EDS) allows the efficient estimation of free-energy differences between multiple end-states from a single molecular dynamics (MD) simulation. In EDS, a reference state is sampled, which can be tuned by two types of parameters, i.e., smoothness parameters(s) and energy offsets, such that all end-states are sufficiently sampled. However, the choice of these parameters is not trivial. Replica exchange (RE) or parallel tempering is a widely applied technique to enhance sampling. By combining EDS with the RE technique, the parameter choice problem could be simplified and the challenge shifted toward an optimal distribution of the replicas in the smoothness-parameter space. The choice of a certain replica distribution can alter the sampling efficiency significantly. In this work, global round-trip time optimization (GRTO) algorithms are tested for the use in RE-EDS simulations. In addition, a local round-trip time optimization (LRTO) algorithm is proposed for systems with slowly adapting environments, where a reliable estimate for the round-trip time is challenging to obtain. The optimization algorithms were applied to RE-EDS simulations of a system of nine small-molecule inhibitors of phenylethanolamine N-methyltransferase (PNMT). The energy offsets were determined using our recently proposed parallel energy-offset (PEOE) estimation scheme. While the multistate GRTO algorithm yielded the best replica distribution for the ligands in water, the multistate LRTO algorithm was found to be the method of choice for the ligands in complex with PNMT. With this, the 36 alchemical free-energy differences between the nine ligands were calculated successfully from a single RE-EDS simulation 10 ns in length. Thus, RE-EDS presents an efficient method for the estimation of relative binding free energies.
Diagnosis of Lung Cancer in Small Biopsies and Cytology
Travis, William D.; Brambilla, Elisabeth; Noguchi, Masayuki; Nicholson, Andrew G.; Geisinger, Kim; Yatabe, Yasushi; Ishikawa, Yuichi; Wistuba, Ignacio; Flieder, Douglas B.; Franklin, Wilbur; Gazdar, Adi; Hasleton, Philip S.; Henderson, Douglas W.; Kerr, Keith M.; Petersen, Iver; Roggli, Victor; Thunnissen, Erik; Tsao, Ming
2015-01-01
The new International Association for the Study of Lung Cancer/American Thoracic Society/European Respiratory Society lung adenocarcinoma classification provides, for the first time, standardized terminology for lung cancer diagnosis in small biopsies and cytology; this was not primarily addressed by previous World Health Organization classifications. Until recently there have been no therapeutic implications to further classification of NSCLC, so little attention has been given to the distinction of adenocarcinoma and squamous cell carcinoma in small tissue samples. This situation has changed dramatically in recent years with the discovery of several therapeutic options that are available only to patients with adenocarcinoma or NSCLC, not otherwise specified, rather than squamous cell carcinoma. This includes recommendation for use of special stains as an aid to diagnosis, particularly in the setting of poorly differentiated tumors that do not show clear differentiation by routine light microscopy. A limited diagnostic workup is recommended to preserve as much tissue for molecular testing as possible. Most tumors can be classified using a single adenocarcinoma marker (eg, thyroid transcription factor 1 or mucin) and a single squamous marker (eg, p40 or p63). Carcinomas lacking clear differentiation by morphology and special stains are classified as NSCLC, not otherwise specified. Not otherwise specified carcinomas that stain with adenocarcinoma markers are classified as NSCLC, favor adenocarcinoma, and tumors that stain only with squamous markers are classified as NSCLC, favor squamous cell carcinoma. The need for every institution to develop a multidisciplinary tissue management strategy to obtain these small specimens and process them, not only for diagnosis but also for molecular testing and evaluation of markers of resistance to therapy, is emphasized. PMID:22970842
Scheuhammer, A M; Lord, S I; Wayland, M; Burgess, N M; Champoux, L; Elliott, J E
2016-03-01
We investigated mercury (Hg) concentrations in small fish (mainly yellow perch, Perca flavescens; ∼60% of fish collected) and in blood of common loons (Gavia immer) that prey upon them during the breeding season on lakes in 4 large, widely separated study areas in Canada (>13 lakes per study area; total number of lakes = 93). Although surface sediments from lakes near a base metal smelter in Flin Flon, Manitoba had the highest Hg concentrations, perch and other small fish and blood of common loon chicks sampled from these same lakes had low Hg concentrations similar to those from uncontaminated reference lakes. Multiple regression modeling with AIC analysis indicated that lake pH was by far the most important single factor influencing perch Hg concentrations in lakes across the four study areas (R(2) = 0.29). The best model was a three-variable model (pH + alkalinity + sediment Se; Wi = 0.61, R(2) = 0.85). A single-variable model (fish Hg) best explained among-lake variability in loon chick blood Hg (Wi = 0.17; R(2) = 0.53). From a toxicological risk perspective, all lakes posing a potential Hg health risk for perch and possibly other small pelagic fish species (where mean fish muscle Hg concentrations exceeded 2.4 μg/g dry wt.), and for breeding common loons (where mean fish muscle Hg concentrations exceeded 0.8 μg/g dry wt., and loon chick blood Hg exceeded 1.4 μg/g dry wt.) had pH < 6.7 and were located in eastern Canada. Crown Copyright © 2016. Published by Elsevier Ltd. All rights reserved.
Siah, Ali; Bomble, Myriam; Tisserant, Benoit; Cadalen, Thierry; Holvoet, Maxime; Hilbert, Jean-Louis; Halama, Patrice; Reignault, Philippe Lucien
2018-04-16
Population genetic structure of the worldwide-distributed wheat pathogen Zymoseptoria tritici has been extensively studied at large geographical scales, but to a much less extent at small or local spatial scales. A total of 627 single-conidial fungal isolates were sampled from several locations in northern France (Hauts-de-France Region) to assess fungal genetic structure at region, field, plant and leaf layer scales, using highly polymorphic microsatellite markers and mating type idiomorphs. Important and overall similar levels of both gene and genotype diversities (gene diversity values ≥ 0.44 and haplotype frequencies ≥ 94 %) were found at all the examined scales. Such rates of diversity are likely due to an active sexual recombination in the investigated areas, as revealed by equal proportions of the two mating types scored in all sampled populations. Interestingly, a rare occurrence of clones among lesions from a same leaf, as well as among leaves from different plant leaf layers (e.g. upper vs lower leaves), was highlighted, indicating that ascospores contribute much more than expected to Z. tritci epidemics, compared to pycnidiospores. Population structure and AMOVA analyses revealed significant genetic differentiation at the regional scale (GST = 0.23) and, as expected, not at the other more local scales (GST ≤ 0.01). Further analyses using Bayesian and unweighted neighbor-joining statistical methods detected six genetic clusters within the regional population, overall distributed according to the locations from which the isolates were sampled. Neither clear directional relative migration linked to the geographical distribution of the locations, nor isolation by distance, were observed. Separate evolutionary trajectories caused by selection and adaptations to habitat heterogeneity could be the main forces shaping such structuration. This study provides new insights into the epidemiology and the genetic structure of Z. tritici at small local and, for the first time, at single plant and leaf layer scales. Such findings would be helpful in implementing effective control strategies.
Xiao, Limin; Jin, Wei; Demokan, M S
2007-01-15
We demonstrate a novel method for low-loss splicing small-core photonic crystal fibers (PCFs) and single-mode fibers (SMFs) by repeated arc discharges using a conventional fusion splicer. An optimum mode field match at the interface of PCF-SMF and an adiabatic mode field variation in the longitudinal direction of the small-core PCF can be achieved by repeated arc discharges applied over the splicing joint to gradually collapse the air holes of the small-core PCF. This method is simple and offers a practical solution for light coupling between small-core PCFs and SMFs.
Fusion splicing small-core photonic crystal fibers and single-mode fibers by repeated arc discharges
NASA Astrophysics Data System (ADS)
Xiao, Limin; Jin, Wei; Demokan, M. S.
2007-01-01
We demonstrate a novel method for low-loss splicing small-core photonic crystal fibers (PCFs) and single-mode fibers (SMFs) by repeated arc discharges using a conventional fusion splicer. An optimum mode field match at the interface of PCF-SMF and an adiabatic mode field variation in the longitudinal direction of the small-core PCF can be achieved by repeated arc discharges applied over the splicing joint to gradually collapse the air holes of the small-core PCF. This method is simple and offers a practical solution for light coupling between small-core PCFs and SMFs.
Schlottmann, Jamie L.; Funkhouser, Ron A.
1991-01-01
Chemical analyses of water from eight test holes and geophysical logs for nine test holes drilled in the Central Oklahoma aquifer are presented. The test holes were drilled to investigate local occurrences of potentially toxic, naturally occurring trace substances in ground water. These trace substances include arsenic, chromium, selenium, residual alpha-particle activities, and uranium. Eight of the nine test holes were drilled near wells known to contain large concentrations of one or more of the naturally occurring trace substances. One test hole was drilled in an area known to have only small concentrations of any of the naturally occurring trace substances.Water samples were collected from one to eight individual sandstone layers within each test hole. A total of 28 water samples, including four duplicate samples, were collected. The temperature, pH, specific conductance, alkalinity, and dissolved-oxygen concentrations were measured at the sample site. Laboratory determinations included major ions, nutrients, dissolved organic carbon, and trace elements (aluminum, arsenic, barium, beryllium, boron, cadmium, chromium, hexavalent chromium, cobalt, copper, iron, lead, lithium, manganese, mercury, molybdenum, nickel, selenium, silver, strontium, vanadium and zinc). Radionuclide activities and stable isotope (5 values also were determined, including: gross-alpha-particle activity, gross-beta-particle activity, radium-226, radium-228, radon-222, uranium-234, uranium-235, uranium-238, total uranium, carbon-13/carbon-12, deuterium/hydrogen-1, oxygen-18/oxygen-16, and sulfur-34/sulfur-32. Additional analyses of arsenic and selenium species are presented for selected samples as well as analyses of density and iodine for two samples, tritium for three samples, and carbon-14 for one sample.Geophysical logs for most test holes include caliper, neutron, gamma-gamma, natural-gamma logs, spontaneous potential, long- and short-normal resistivity, and single-point resistance. Logs for test-hole NOTS 7 do not include long- and short-normal resistivity, spontaneous-potential, or single-point resistivity. Logs for test-hole NOTS 7A include only caliper and natural-gamma logs.
Fino, Peter C; Parrington, Lucy; Pitt, Will; Martini, Douglas N; Chesnutt, James C; Chou, Li-Shan; King, Laurie A
2018-05-01
While a growing number of studies have investigated the effects of concussion or mild traumatic brain injury (mTBI) on gait, many studies use different experimental paradigms and outcome measures. The path for translating experimental studies for objective clinical assessments of gait is unclear. This review asked 2 questions: 1) is gait abnormal after concussion/mTBI, and 2) what gait paradigms (single-task, dual-task, complex gait) detect abnormalities after concussion. Data sources included MEDLINE/PubMed, Scopus, Web of Science, and Cumulative Index to Nursing and Allied Health Literature (CINAHL) accessed on March 14, 2017. Original research articles reporting gait outcomes in people with concussion or mTBI were included. Studies of moderate, severe, or unspecified TBI, and studies without a comparator were excluded. After screening 233 articles, 38 studies were included and assigned to one or more sections based on the protocol and reported outcomes. Twenty-six articles reported single-task simple gait outcomes, 24 reported dual-task simple gait outcomes, 21 reported single-task complex gait outcomes, and 10 reported dual-task complex gait outcomes. Overall, this review provides evidence for two conclusions: 1) gait is abnormal acutely after concussion/mTBI but generally resolves over time; and 2) the inconsistency of findings, small sample sizes, and small number of studies examining homogenous measures at the same time-period post-concussion highlight the need for replication across independent populations and investigators. Future research should concentrate on dual-task and complex gait tasks, as they showed promise for detecting abnormal locomotor function outside of the acute timeframe. Additionally, studies should provide detailed demographic and clinical characteristics to enable more refined comparisons across studies. Copyright © 2018 Elsevier B.V. All rights reserved.
Diversity of coding profiles of mechanoreceptors in glabrous skin of kittens.
Gibson, J M; Beitel, R E; Welker, W
1975-03-21
We examined stimulul-response (S-R) profiles of 35 single mechanoreceptive afferent units having small receptive fields in glabrous forepaw skin of 24 anesthetized domestic kittens. Single unit activity was recorded with tungsten microelectrodes from cervical dorsal root ganglia. The study was designed to be as quantitatively descriptive as possible. We indented each unit's receptive field with a broad battery of simple, carefully controlled stimuli whose major parameters, including amplitude, velocity, acceleration, duration, and interstimulus interval were systematically varied. Stimuli were delivered by a small probe driven by a feedback-controlled axial displacement generator. Single unit discharge data were analyzed by a variety of direct and derived measures including dot patterns, peristimulus histograms, instantaneous and mean instantaneous firing rates, tuning curves, thresholds for amplitude and velocity, adaptation rates, dynamic and static sensitivities, and others. We found that with respect to any of the S-R transactions examined, the properties of our sample of units were continuously and broadly distributed. Any one unit might exhibit either a slow or rapid rate of adaptation, or might superficially appear to preferentially code a single stimulus parameter such as amplitude or velocity. But when the entire range of responsiveness of units to the entire stimulus battery was surveyed by a variety of analytic techniques, we were unable to find any justifiable basis for designation of discrete categories of S-R profiles. Intermediate response types were always found, and in general, all units were both broadly tuned and capable of responding to integrals of several stimulus parameters, our data argue against the usefulness of evaluating a unit's S-R coding capabilities by means of a limited ste of stimulation of response analysis procedures.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gonçalves, Daniela
Opicapone is a novel potent, reversible and purely peripheral catechol-O-methyltransferase inhibitor that has been developed to be used as an adjunct to levodopa/aromatic L-amino acid decarboxylase inhibitor therapy for Parkinson's disease. Thus, this study aimed to compare the plasma pharmacokinetics of opicapone and its active metabolite (BIA 9-1079) after the administration of single and multiple oral doses to rats. Wistar rats (n = 8 per group) were orally treated with single (30, 60 or 90 mg/kg) or multiple (30 mg/kg once-daily for seven consecutive days) oral doses of opicapone. Blood samples were collected up to 24 h post-dosing through amore » cannula introduced in the tail vein of rats. After quantifying opicapone and BIA 9-1079 in plasma, a non-compartmental pharmacokinetic analysis was performed. Opicapone was quickly absorbed (time to reach the maximum plasma concentration ≤ 2 h) in both dosage regimens and the extent of systemic exposure to opicapone increased approximately in a dose-proportional manner after single-dosing within the studied dose range (30–90 mg/kg). Opicapone and BIA 9-1079 showed a relatively short plasma elimination half-life (1.58–4.50 h) and a small systemic accumulation after multiple-dosing. Hence, no pharmacokinetic concerns are expected when opicapone is administered with a once-daily dosing regimen. - Highlights: • Opicapone is relatively rapid absorbed after oral administration to rats. • Systemic exposure to opicapone increases approximately in a dose-proportional manner. • Opicapone and BIA 9-1079 show a small systemic accumulation after multiple-dosing.« less
Lim, Byung Chan; Lee, Seungbok; Shin, Jong-Yeon; Kim, Jong-Il; Hwang, Hee; Kim, Ki Joong; Hwang, Yong Seung; Seo, Jeong-Sun; Chae, Jong Hee
2011-11-01
Duchenne muscular dystrophy or Becker muscular dystrophy might be a suitable candidate disease for application of next-generation sequencing in the genetic diagnosis because the complex mutational spectrum and the large size of the dystrophin gene require two or more analytical methods and have a high cost. The authors tested whether large deletions/duplications or small mutations, such as point mutations or short insertions/deletions of the dystrophin gene, could be predicted accurately in a single platform using next-generation sequencing technology. A custom solution-based target enrichment kit was designed to capture whole genomic regions of the dystrophin gene and other muscular-dystrophy-related genes. A multiplexing strategy, wherein four differently bar-coded samples were captured and sequenced together in a single lane of the Illumina Genome Analyser, was applied. The study subjects were 25 16 with deficient dystrophin expression without a large deletion/duplication and 9 with a known large deletion/duplication. Nearly 100% of the exonic region of the dystrophin gene was covered by at least eight reads with a mean read depth of 107. Pathogenic small mutations were identified in 15 of the 16 patients without a large deletion/duplication. Using these 16 patients as the standard, the authors' method accurately predicted the deleted or duplicated exons in the 9 patients with known mutations. Inclusion of non-coding regions and paired-end sequence analysis enabled accurate identification by increasing the read depth and providing information about the breakpoint junction. The current method has an advantage for the genetic diagnosis of Duchenne muscular dystrophy and Becker muscular dystrophy wherein a comprehensive mutational search may be feasible using a single platform.
Gallium ion-assisted room temperature synthesis of small-diameter ZnO nanorods.
Cho, Seungho; Kim, Semi; Lee, Kun-Hong
2011-09-15
We report a method for synthesizing small-diameter ZnO nanorods at room temperature (20 °C), under normal atmospheric pressure (1 atm), and using a relatively short reaction time (1 h) by adding gallium salts to the reaction solution. The ZnO nanorods were, on average, 92 nm in length and 9 nm in diameter and were single crystalline in nature. Quantitative analyses revealed that gallium atoms were not incorporated into the synthesized nanocrystals. On the basis of the experimental results, we propose a mechanism for the formation of small-diameter ZnO nanorods in the presence of gallium ions. The optical properties were probed by UV-Vis diffuse reflectance spectroscopy. The absorption band of the small-diameter ZnO nanorods was blue-shifted relative to the absorption band of the ~230 nm diameter ZnO nanorods (control samples). Control experiments demonstrated that the absence of metal ion-containing precipitants (except ZnO) at room temperature is essential, and that the ZnO nanorod diameter distributions were narrow for the stirred reaction solution and broad when prepared without stirring. Copyright © 2011 Elsevier Inc. All rights reserved.
Luminescence properties after X-ray irradiation for dosimetry
NASA Astrophysics Data System (ADS)
Hong, Duk-Geun; Kim, Myung-Jin
2016-05-01
To investigate the luminescence characteristics after exposure to X-ray radiation, we developed an independent, small X-ray irradiation system comprising a Varian VF-50J mini X-ray generator, a Pb collimator, a delay shutter, and an Al absorber. With this system, the apparent dose rate increased linearly to 0.8 Gy/s against the emission current for a 50 kV anode potential when the shutter was delayed for an initial 4 s and the Al absorber was 300 µm thick. In addition, an approximately 20 mm diameter sample area was irradiated homogeneously with X rays. Based on three-dimensional (3D) thermoluminescence (TL) spectra, the small X-ray irradiator was considered comparable to the conventional 90Sr/90Y beta source even though the TL intensity from beta irradiation was higher than that from X-ray irradiation. The single aliquot regenerative (SAR) growth curve for the small X-ray irradiator was identical to that for the beta source. Therefore, we concluded that the characteristics of the small X-ray irradiator and the conventional 90Sr/90Y beta source were similar and that X ray irradiation had the potential for being suitable for use in luminescence dosimetry.
Production of multi-, oligo- and single-pore membranes using a continuous ion beam
NASA Astrophysics Data System (ADS)
Apel, P. Yu.; Ivanov, O. M.; Lizunov, N. E.; Mamonova, T. I.; Nechaev, A. N.; Olejniczak, K.; Vacik, J.; Dmitriev, S. N.
2015-12-01
Ion track membranes (ITM) have attracted significant interest over the past two decades due to their numerous applications in physical, biological, chemical, biochemical and medical experimental works. A particular feature of ITM technology is the possibility to fabricate samples with a predetermined number of pores, including single-pore membranes. The present report describes a procedure that allowed for the production of multi-, oligo- and single-pore membranes using a continuous ion beam from an IC-100 cyclotron. The beam was scanned over a set of small diaphragms, from 17 to ∼1000 μm in diameter. Ions passed through the apertures and impinged two sandwiched polymer foils, with the total thickness close to the ion range in the polymer. The foils were pulled across the ion beam at a constant speed. The ratio between the transport speed and the scanning frequency determined the distance between irradiation spots. The beam intensity and the aperture diameters were adjusted such that either several, one or no ions passed through the diaphragms during one half-period of scanning. After irradiation, the lower foil was separated from the upper foil and was etched to obtain pores 6-8 μm in diameter. The pores were found using a color chemical reaction between two reagents placed on opposite sides of the foil. The located pores were further confirmed using SEM and optical microscopy. The numbers of tracks in the irradiation spots were consistent with the Poisson statistics. Samples with single or few tracks obtained in this way were employed to study fine phenomena in ion track nanopores.
Circular single domains in hemispherical Permalloy nanoclusters
DOE Office of Scientific and Technical Information (OSTI.GOV)
Araujo, Clodoaldo I. L de, E-mail: dearaujo@ufv.br; Fonseca, Jakson M.; Sinnecker, João P.
2014-11-14
We have studied ferromagnetic Permalloy clusters obtained by electrodeposition on n-type silicon. Magnetization measurements reveal hysteresis loops almost independent on temperature and very similar in shape to those obtained in nanodisks with diameter bigger than 150 nm. The spin configuration for the ground state, obtained by micromagnetic simulation, shows topological vortices with random chirality and polarization. This behavior in the small diameter clusters (∼80 nm) is attributed to the Dzyaloshinskii-Moriya interaction that arises in its hemispherical geometries. This magnetization behavior can be utilized to explain the magnetoresistance measured with magnetic field in plane and out of sample plane.
Aerosol emissions from forest and grassland burnings in the southern amazon basin and central Brazil
NASA Astrophysics Data System (ADS)
Leslie, Alistair C. D.
1981-03-01
Forest and grassland clearing by means of prescribed fires in tropical areas of the world may be responsible for large inputs of fine particulates to the global atmosphere besides being a major source of trace gases. The major continents on which extensive biomass burning takes place are Africa and South America. Such agricultural practices of burning have been employed throughout man's existence, but the importance and significance of such burning relative to anthropogenic industrial emissions to the atmosphere has not until extremely recently been seriously studied. In August-September 1979 project "Brushfire 1979" took place based in Brasília, Brazil. The Air Quality Division of the National Center for Atmospheric Research made ground level and aircraft measurements of trace gases (e.g. CO 2, CO, CH 4, N 2O, H 2, CH 3Cl, COS, NO, NO 2, O 3) and Florida State University sampled ground level aerosol emissions from grass and forest burnings. Aerosols were sampled using plastic 7-stage single orifice cascade impactors and FSU type linear and circular "streakers". Long term sampling was made of regional background for total particulates (<15 μmad) with 2 h resolution using streakers and with impactors for 24 h resolution of 7 particle size fractions (<0.25 to >8 μmad). Short term sampling within grass or forest fires was made using impactors incorporated into portable kits containing 4 miniature 12-18 V dc Brailsford pumps and a disposable dry cell power pack. Sampling times of 5-15 min were found optimal under these conditions. Grass fires were sampled in the savannah area northeast of Brasília and forest fires in the state of Mato Grosso on the southern edge of the dryland forest of the Amazon basin. Residual ash samples were collected. All of the samples were analyzed at Florida State University using PIXE for 15-20 elements including Mg, Al, Si, P, S, Cl, K, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Br, Pb and Sr. Computer reduction of the X-ray spectra was made using the "HEXB" program. One of the prominent features found was the large flux of small particles (<2.0 μm) from both fire types. P, S and Cl were mostly small particle, Mg, Al, Si and K showed a bimodal distribution biased towards the small particle range, while Ca, Ti and Fe (crustal elements) predominated in the large particle mode. As Cl was found to be exclusively small particle, a formation mechanism in which HCl gas neutralizes small organic particles containing P and S may be hypothesized. A much more extensive field program for the summer of 1980 is planned to take place in the central Amazon basin using ground and airborne aerosol samplers, to capitalize on the work pioneered in this study.
NASA Astrophysics Data System (ADS)
Hatakeyama, Rokuro; Yoshizawa, Masazumi; Moriya, Tadashi
2000-11-01
Precise correction for γ-ray attenuation in skull bone has been a significant problem in obtaining quantitative single photon emission computed tomography (SPECT) images. The correction for γ-ray attenuation is approximately proportional to the density and thickness of the bone under investigation. If the acoustic impedance and the speed of sound in bone are measurable using ultrasonic techniques, then the density and thickness of the bone sample can be calculated. Whole bone usually consists of three layers, and each layer has a different ultrasonic character. Thus, the speed of sound must be measured in a small section of each layer in order to determine the overall density of whole bone. It is important to measure the attenuation constant in order to determine the appropriate level for the ultrasonic input signal. We have developed a method for measuring the acoustic impedance, speed of sound, and attenuation constant in a small region of a bone sample using a fused quartz rod as a transmission line. In the present study, we obtained the following results: impedance of compact bone; 5.30(±0.40)× 106 kg/(m2s), speed of sound; 3780± 250 m/s, and attenuation constant; 2.70± 0.50 Np/m. These results were used to obtain the densities of compact bone, spongy bone and bone marrow in a bovine bone sample and as well as the density of pig skull bone, which were found to be 1.40± 0.30 g/cm3, 1.19± 0.50 g/cm3, 0.90± 0.30 g/cm3 and 1.26± 0.30 g/cm3, respectively. Using a thin solid transmission line, the proposed method makes it possible to determine the density of a small region of a bone sample. It is expected that the proposed method, which is based on ultrasonic measurement, will be useful for application in brain SPECT.
7 CFR 43.104 - Master table of single and double sampling plans.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 7 Agriculture 2 2012-01-01 2012-01-01 false Master table of single and double sampling plans. 43... STANDARD CONTAINER REGULATIONS STANDARDS FOR SAMPLING PLANS Sampling Plans § 43.104 Master table of single and double sampling plans. (a) In the master table, a sampling plan is selected by first determining...
7 CFR 43.104 - Master table of single and double sampling plans.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 7 Agriculture 2 2013-01-01 2013-01-01 false Master table of single and double sampling plans. 43... STANDARD CONTAINER REGULATIONS STANDARDS FOR SAMPLING PLANS Sampling Plans § 43.104 Master table of single and double sampling plans. (a) In the master table, a sampling plan is selected by first determining...
7 CFR 43.104 - Master table of single and double sampling plans.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 7 Agriculture 2 2014-01-01 2014-01-01 false Master table of single and double sampling plans. 43... STANDARD CONTAINER REGULATIONS STANDARDS FOR SAMPLING PLANS Sampling Plans § 43.104 Master table of single and double sampling plans. (a) In the master table, a sampling plan is selected by first determining...
7 CFR 43.104 - Master table of single and double sampling plans.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 7 Agriculture 2 2011-01-01 2011-01-01 false Master table of single and double sampling plans. 43... STANDARD CONTAINER REGULATIONS STANDARDS FOR SAMPLING PLANS Sampling Plans § 43.104 Master table of single and double sampling plans. (a) In the master table, a sampling plan is selected by first determining...
NASA Technical Reports Server (NTRS)
Peters, Gregory
2010-01-01
A field-deployable, battery-powered Rapid Active Sampling Package (RASP), originally designed for sampling strong materials during lunar and planetary missions, shows strong utility for terrestrial geological use. The technology is proving to be simple and effective for sampling and processing materials of strength. Although this originally was intended for planetary and lunar applications, the RASP is very useful as a powered hand tool for geologists and the mining industry to quickly sample and process rocks in the field on Earth. The RASP allows geologists to surgically acquire samples of rock for later laboratory analysis. This tool, roughly the size of a wrench, allows the user to cut away swaths of weathering rinds, revealing pristine rock surfaces for observation and subsequent sampling with the same tool. RASPing deeper (.3.5 cm) exposes single rock strata in-situ. Where a geologist fs hammer can only expose unweathered layers of rock, the RASP can do the same, and then has the added ability to capture and process samples into powder with particle sizes less than 150 microns, making it easier for XRD/XRF (x-ray diffraction/x-ray fluorescence). The tool uses a rotating rasp bit (or two counter-rotating bits) that resides inside or above the catch container. The container has an open slot to allow the bit to extend outside the container and to allow cuttings to enter and be caught. When the slot and rasp bit are in contact with a substrate, the bit is plunged into it in a matter of seconds to reach pristine rock. A user in the field may sample a rock multiple times at multiple depths in minutes, instead of having to cut out huge, heavy rock samples for transport back to a lab for analysis. Because of the speed and accuracy of the RASP, hundreds of samples can be taken in one day. RASP-acquired samples are small and easily carried. A user can characterize more area in less time than by using conventional methods. The field-deployable RASP used a Ni/Cad rechargeable battery. Power usage was less than 1 Wh/ cm3 even when sampling strong basalts, so many samples could be taken on a single battery charge.
Morimoto, Atsushi; Mogami, Toshifumi; Watanabe, Masaru; Iijima, Kazuki; Akiyama, Yasuyuki; Katayama, Koji; Futami, Toru; Yamamoto, Nobuyuki; Sawada, Takeshi; Koizumi, Fumiaki; Koh, Yasuhiro
2015-01-01
Development of a reliable platform and workflow to detect and capture a small number of mutation-bearing circulating tumor cells (CTCs) from a blood sample is necessary for the development of noninvasive cancer diagnosis. In this preclinical study, we aimed to develop a capture system for molecular characterization of single CTCs based on high-density dielectrophoretic microwell array technology. Spike-in experiments using lung cancer cell lines were conducted. The microwell array was used to capture spiked cancer cells, and captured single cells were subjected to whole genome amplification followed by sequencing. A high detection rate (70.2%-90.0%) and excellent linear performance (R2 = 0.8189-0.9999) were noted between the observed and expected numbers of tumor cells. The detection rate was markedly higher than that obtained using the CellSearch system in a blinded manner, suggesting the superior sensitivity of our system in detecting EpCAM- tumor cells. Isolation of single captured tumor cells, followed by detection of EGFR mutations, was achieved using Sanger sequencing. Using a microwell array, we established an efficient and convenient platform for the capture and characterization of single CTCs. The results of a proof-of-principle preclinical study indicated that this platform has potential for the molecular characterization of captured CTCs from patients.
Quantum model of a hysteresis in a single-domain magnetically soft ferromagnetic
NASA Astrophysics Data System (ADS)
Ignatiev, V. K.; Lebedev, N. G.; Orlov, A. A.
2018-01-01
A quantum model of a single-domain magnetically soft ferromagnetic is proposed. The α-Fe crystal in a state of the saturation magnetization and a variable magnetic field is considered as a sample. The method of an effective Hamiltonian, including the operators of the Zeeman energy, the spin-orbit interaction and the interaction with the crystal field, is used in the model. An expansion of trial single-electron wave function in a series in small parameter of the spin-orbit interaction is suggested to account for the magnetic anisotropy. Within the framework of the Heisenberg representation, the nonlinear equations of motion for the magnetization and the orbital moment of single domain are obtained. Parameters of the modelling Hamiltonian are found from a comparison with experimental data on the magnetic anisotropy of iron. A phenomenological term of the magnetic friction is introduced into equation of the magnetization motion. Nonlinear equations are solved numerically by the Runge-Kutta method. A dependence of the single domain magnetization on magnetic field intensity has a characteristic form of a hysteresis loop which parameters are quantitatively coordinated with experimental data of researches of magnetic properties of nanoparticles of iron and iron oxide. The method is extended for modelling the magnetization dynamics of multi-domain ferromagnetic in the approximation of a strong crystal field.
Koana, Takao; Takahashi, Takashi; Tsujimura, Hidenobu
2012-03-01
The third instar larvae of Drosophila were irradiated with X rays, and the somatic mutation frequency in their wings was measured after their eclosion. In the flies with normal DNA repair and apoptosis functions, 0.2 Gy irradiation at 0.05 Gy/min reduced the frequency of the so-called small spot (mutant cell clone with reduced reproductive activity) compared with that in the sham-irradiated flies. When apoptosis was suppressed using the baculovirus p35 gene, the small spot frequency increased four times in the sham-irradiated control group, but the reduction by the 0.2-Gy irradiation was still evident. In a non-homologous end joining-deficient mutant, the small spot frequency was also reduced by 0.2 Gy radiation. In a mutant deficient in single-strand break repair, no reduction in the small spot frequency by 0.2 Gy radiation was observed, and the small spot frequency increased with the radiation dose. Large spot (mutant cell clone with normal reproductive activity) frequency was not affected by suppression of apoptosis and increased monotonically with radiation dose in wild-type larvae and in mutants for single- or double-strand break repair. It is hypothesized that some of the small spots resulted from single-strand damage and, in wild-type larvae, 0.2 Gy radiation activated the normal single-strand break repair gene, which reduced the background somatic mutation frequency.
Low cost light-sheet microscopy for whole brain imaging
NASA Astrophysics Data System (ADS)
Kumar, Manish; Nasenbeny, Jordan; Kozorovitskiy, Yevgenia
2018-02-01
Light-sheet microscopy has evolved as an indispensable tool in imaging biological samples. It can image 3D samples at fast speed, with high-resolution optical sectioning, and with reduced photobleaching effects. These properties make light-sheet microscopy ideal for imaging fluorophores in a variety of biological samples and organisms, e.g. zebrafish, drosophila, cleared mouse brains, etc. While most commercial turnkey light-sheet systems are expensive, the existing lower cost implementations, e.g. OpenSPIM, are focused on achieving high-resolution imaging of small samples or organisms like zebrafish. In this work, we substantially reduce the cost of light-sheet microscope system while targeting to image much larger samples, i.e. cleared mouse brains, at single-cell resolution. The expensive components of a lightsheet system - excitation laser, water-immersion objectives, and translation stage - are replaced with an incoherent laser diode, dry objectives, and a custom-built Arduino-controlled translation stage. A low-cost CUBIC protocol is used to clear fixed mouse brain samples. The open-source platforms of μManager and Fiji support image acquisition, processing, and visualization. Our system can easily be extended to multi-color light-sheet microscopy.
Vogel, J.R.; Brown, G.O.
2003-01-01
Semivariograms of samples of Culebra Dolomite have been determined at two different resolutions for gamma ray computed tomography images. By fitting models to semivariograms, small-scale and large-scale correlation lengths are determined for four samples. Different semivariogram parameters were found for adjacent cores at both resolutions. Relative elementary volume (REV) concepts are related to the stationarity of the sample. A scale disparity factor is defined and is used to determine sample size required for ergodic stationarity with a specified correlation length. This allows for comparison of geostatistical measures and representative elementary volumes. The modifiable areal unit problem is also addressed and used to determine resolution effects on correlation lengths. By changing resolution, a range of correlation lengths can be determined for the same sample. Comparison of voxel volume to the best-fit model correlation length of a single sample at different resolutions reveals a linear scaling effect. Using this relationship, the range of the point value semivariogram is determined. This is the range approached as the voxel size goes to zero. Finally, these results are compared to the regularization theory of point variables for borehole cores and are found to be a better fit for predicting the volume-averaged range.
Accurate high-speed liquid handling of very small biological samples.
Schober, A; Günther, R; Schwienhorst, A; Döring, M; Lindemann, B F
1993-08-01
Molecular biology techniques require the accurate pipetting of buffers and solutions with volumes in the microliter range. Traditionally, hand-held pipetting devices are used to fulfill these requirements, but many laboratories have also introduced robotic workstations for the handling of liquids. Piston-operated pumps are commonly used in manually as well as automatically operated pipettors. These devices cannot meet the demands for extremely accurate pipetting of very small volumes at the high speed that would be necessary for certain applications (e.g., in sequencing projects with high throughput). In this paper we describe a technique for the accurate microdispensation of biochemically relevant solutions and suspensions with the aid of a piezoelectric transducer. It is suitable for liquids of a viscosity between 0.5 and 500 milliPascals. The obtainable drop sizes range from 5 picoliters to a few nanoliters with up to 10,000 drops per second. Liquids can be dispensed in single or accumulated drops to handle a wide volume range. The system proved to be excellently suitable for the handling of biological samples. It did not show any detectable negative impact on the biological function of dissolved or suspended molecules or particles.
Growns, Ivor; Astles, Karen; Gehrke, Peter
2006-03-01
We studied the multiscale (sites, river reaches and rivers) and short-term temporal (monthly) variability in a freshwater fish assemblage. We found that small-scale spatial variation and short-term temporal variability significantly influenced fish community structure in the Macquarie and Namoi Rivers. However, larger scale spatial differences between rivers were the largest source of variation in the data. The interaction between temporal change and spatial variation in fish community structure, whilst statistically significant, was smaller than the variation between rivers. This suggests that although the fish communities within each river changed between sampling occasions, the underlying differences between rivers were maintained. In contrast, the strongest interaction between temporal and spatial effects occurred at the smallest spatial scale, at the level of individual sites. This means whilst the composition of the fish assemblage at a given site may fluctuate, the magnitude of these changes is unlikely to affect larger scale differences between reaches within rivers or between rivers. These results suggest that sampling at any time within a single season will be sufficient to show spatial differences that occur over large spatial scales, such as comparisons between rivers or between biogeographical regions.
One-shot spectrometer for several elements using an integrated conical crystal analyzer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Morishita, Kohei; Nakajima, Kazuo; Hayashi, Kouichi
Time-resolved x-ray spectrometry using an ultrastrong x-ray source such as an x-ray free electron laser is one of the new trends in the field of x-ray physics. To achieve such time-resolved measurement, the development of an one-shot spectrometer with a wide wavelength range, high efficiency, and good energy resolution is an essential prerequisite. Here we developed an integrated conical Ge crystal analyzer consisting of several conical rings, which were connected using spline surfaces to form a single body using our previously developed hot deformation technique, which can form a Si or Ge wafer into an arbitrary and accurate shape. Wemore » simultaneously focused several characteristic lines from an alloy sample onto different positions on a small x-ray charge-coupled device with very high image brightness (gain relative to planar analyzer: 100) and a good spatial resolution of 9-13 eV. The small radius of curvature of the crystal (28-50 mm) enabled us to realize a very short sample-detector distance of 214.4 mm. The present result shows the possibility of realizing a new focusing x-ray crystal spectrograph that can control the focal position as desired.« less
Unbiased multi-fidelity estimate of failure probability of a free plane jet
NASA Astrophysics Data System (ADS)
Marques, Alexandre; Kramer, Boris; Willcox, Karen; Peherstorfer, Benjamin
2017-11-01
Estimating failure probability related to fluid flows is a challenge because it requires a large number of evaluations of expensive models. We address this challenge by leveraging multiple low fidelity models of the flow dynamics to create an optimal unbiased estimator. In particular, we investigate the effects of uncertain inlet conditions in the width of a free plane jet. We classify a condition as failure when the corresponding jet width is below a small threshold, such that failure is a rare event (failure probability is smaller than 0.001). We estimate failure probability by combining the frameworks of multi-fidelity importance sampling and optimal fusion of estimators. Multi-fidelity importance sampling uses a low fidelity model to explore the parameter space and create a biasing distribution. An unbiased estimate is then computed with a relatively small number of evaluations of the high fidelity model. In the presence of multiple low fidelity models, this framework offers multiple competing estimators. Optimal fusion combines all competing estimators into a single estimator with minimal variance. We show that this combined framework can significantly reduce the cost of estimating failure probabilities, and thus can have a large impact in fluid flow applications. This work was funded by DARPA.
NASA Astrophysics Data System (ADS)
Jenk, Theo Manuel; Rubino, Mauro; Etheridge, David; Ciobanu, Viorela Gabriela; Blunier, Thomas
2016-08-01
Palaeoatmospheric records of carbon dioxide and its stable carbon isotope composition (δ13C) obtained from polar ice cores provide important constraints on the natural variability of the carbon cycle. However, the measurements are both analytically challenging and time-consuming; thus only data exist from a limited number of sampling sites and time periods. Additional analytical resources with high analytical precision and throughput are thus desirable to extend the existing datasets. Moreover, consistent measurements derived by independent laboratories and a variety of analytical systems help to further increase confidence in the global CO2 palaeo-reconstructions. Here, we describe our new set-up for simultaneous measurements of atmospheric CO2 mixing ratios and atmospheric δ13C and δ18O-CO2 in air extracted from ice core samples. The centrepiece of the system is a newly designed needle cracker for the mechanical release of air entrapped in ice core samples of 8-13 g operated at -45 °C. The small sample size allows for high resolution and replicate sampling schemes. In our method, CO2 is cryogenically and chromatographically separated from the bulk air and its isotopic composition subsequently determined by continuous flow isotope ratio mass spectrometry (IRMS). In combination with thermal conductivity measurement of the bulk air, the CO2 mixing ratio is calculated. The analytical precision determined from standard air sample measurements over ice is ±1.9 ppm for CO2 and ±0.09 ‰ for δ13C. In a laboratory intercomparison study with CSIRO (Aspendale, Australia), good agreement between CO2 and δ13C results is found for Law Dome ice core samples. Replicate analysis of these samples resulted in a pooled standard deviation of 2.0 ppm for CO2 and 0.11 ‰ for δ13C. These numbers are good, though they are rather conservative estimates of the overall analytical precision achieved for single ice sample measurements. Facilitated by the small sample requirement, replicate measurements are feasible, allowing the method precision to be improved potentially. Further, new analytical approaches are introduced for the accurate correction of the procedural blank and for a consistent detection of measurement outliers, which is based on δ18O-CO2 and the exchange of oxygen between CO2 and the surrounding ice (H2O).
Mapping mountain pine beetle mortality through growth trend analysis of time-series landsat data
Liang, Lu; Chen, Yanlei; Hawbaker, Todd J.; Zhu, Zhi-Liang; Gong, Peng
2014-01-01
Disturbances are key processes in the carbon cycle of forests and other ecosystems. In recent decades, mountain pine beetle (MPB; Dendroctonus ponderosae) outbreaks have become more frequent and extensive in western North America. Remote sensing has the ability to fill the data gaps of long-term infestation monitoring, but the elimination of observational noise and attributing changes quantitatively are two main challenges in its effective application. Here, we present a forest growth trend analysis method that integrates Landsat temporal trajectories and decision tree techniques to derive annual forest disturbance maps over an 11-year period. The temporal trajectory component successfully captures the disturbance events as represented by spectral segments, whereas decision tree modeling efficiently recognizes and attributes events based upon the characteristics of the segments. Validated against a point set sampled across a gradient of MPB mortality, 86.74% to 94.00% overall accuracy was achieved with small variability in accuracy among years. In contrast, the overall accuracies of single-date classifications ranged from 37.20% to 75.20% and only become comparable with our approach when the training sample size was increased at least four-fold. This demonstrates that the advantages of this time series work flow exist in its small training sample size requirement. The easily understandable, interpretable and modifiable characteristics of our approach suggest that it could be applicable to other ecoregions.
Razzauti, Maria; Plyusnina, Angelina; Sironen, Tarja; Henttonen, Heikki; Plyusnin, Alexander
2009-08-01
In this study, for the first time, two distinct genetic lineages of Puumala virus (PUUV) were found within a small sampling area and within a single host genetic lineage (Ural mtDNA) at Pallasjärvi, northern Finland. Lung tissue samples of 171 bank voles (Myodes glareolus) trapped in September 1998 were screened for the presence of PUUV nucleocapsid antigen and 25 were found to be positive. Partial sequences of the PUUV small (S), medium (M) and large (L) genome segments were recovered from these samples using RT-PCR. Phylogenetic analysis revealed two genetic groups of PUUV sequences that belonged to the Finnish and north Scandinavian lineages. This presented a unique opportunity to study inter-lineage reassortment in PUUV; indeed, 32 % of the studied bank voles appeared to carry reassortant virus genomes. Thus, the frequency of inter-lineage reassortment in PUUV was comparable to that of intra-lineage reassortment observed previously (Razzauti, M., Plyusnina, A., Henttonen, H. & Plyusnin, A. (2008). J Gen Virol 89, 1649-1660). Of six possible reassortant S/M/L combinations, only two were found at Pallasjärvi and, notably, in all reassortants, both S and L segments originated from the same genetic lineage, suggesting a non-random pattern for the reassortment. These findings are discussed in connection to PUUV evolution in Fennoscandia.
Tagging of Test Tubes with Electronic p-Chips for Use in Biorepositories.
Mandecki, Wlodek; Kopacka, Wesley M; Qian, Ziye; Ertwine, Von; Gedzberg, Katie; Gruda, Maryann; Reinhardt, David; Rodriguez, Efrain
2017-08-01
A system has been developed to electronically tag and track test tubes used in biorepositories. The system is based on a light-activated microtransponder, also known as a "p-Chip." One of the pressing problems with storing and retrieving biological samples at low temperatures is the difficulty of reliably reading the identification (ID) number that links each storage tube with the database containing sample details. Commonly used barcodes are not always reliable at low temperatures because of poor adhesion of the label to the test tube and problems with reading under conditions of frost and ice accumulation. Traditional radio frequency identification (RFID) tags are not cost effective and are too large for this application. The system described herein consists of the p-Chip, p-Chip-tagged test tubes, two ID readers (for single tubes or for racks of tubes), and software. We also describe a robot that is configured for retrofitting legacy test tubes in biorepositories with p-Chips while maintaining the temperature of the sample below -50°C at all times. The main benefits of the p-Chip over other RFID devices are its small size (600 × 600 × 100 μm) that allows even very small tubes or vials to be tagged, low cost due to the chip's unitary construction, durability, and the ability to read the ID through frost and ice.
SPECT/CT of lung nodules using 111In-DOTA-c(RGDfK) in a mouse lung carcinogenesis model.
Hayakawa, Takuya; Mutoh, Michihiro; Imai, Toshio; Tsuta, Koji; Yanaka, Akinori; Fujii, Hirofumi; Yoshimoto, Mitsuyoshi
2013-08-01
Lung cancer is one of the leading causes of cancer-related deaths worldwide, including Japan. Although computed tomography (CT) can detect small lung lesions such as those appearing as ground glass opacity, it cannot differentiate between malignant and non-malignant lesions. Previously, we have shown that single photon emission computed tomography (SPECT) imaging using (111)In-1,4,7,10-tetraazacyclododecane-N,N',N'',N'''-tetraacetic acid-cyclo-(Arg-Gly-Asp-D-Phe-Lys) (DOTA-c(RGDfK)), an imaging probe of αvβ3 integrin, is useful for the early detection of pancreatic cancer in a hamster pancreatic carcinogenesis model. In this study, we aimed to assess the usefulness of SPECT/CT with (111)In-DOTA-c(RGDfK) for the evaluation of the malignancy of lung cancer. Lung tumors were induced by a single intraperitoneal injection (250 mg/kg) of urethane in male A/J mice. Twenty-six weeks after the urethane treatment, SPECT was performed an hour after injection of (111)In-DOTA-c(RGDfK). Following this, the radioactivity ratios of tumor to normal lung tissue were measured by autoradiography (ARG) in the excised lung samples. We also examined the expression of αvβ3 integrin in mouse and human lung samples. Urethane treatment induced 5 hyperplasias, 41 adenomas and 12 adenocarcinomas in the lungs of 8 A/J mice. SPECT with (111)In-DOTA-c(RGDfK) could clearly visualize lung nodules, though we failed to detect small lung nodules like adenoma and hyperplasias (adenocarcinoma: 66.7%, adenoma: 33.6%, hyperplasia: 0.0%). ARG analysis revealed significant uptake of (111)In-DOTA-c(RGDfK) in all the lesions. Moreover, tumor to normal lung tissue ratios increased along with the progression of carcinogenesis. Histopathological examination using human lung tissue samples revealed clear up-regulation of αvβ3 integrin in well-differentiated adenocarcinoma (Noguchi type B and C) rather than atypical adenomatous hyperplasia. Although there are some limitations in evaluating the malignancy of small lung tumors using (111)In-DOTA-c(RGDfK), SPECT with (111)In-DOTA-c(RGDfK) might be a useful non-invasive imaging approach for evaluating the characteristics of lung tumors in mice, thus showing potential for use in humans.