NASA Technical Reports Server (NTRS)
Lauenstein, Jean-Marie
2015-01-01
The JEDEC JESD57 test standard, Procedures for the Measurement of Single-Event Effects in Semiconductor Devices from Heavy-Ion Irradiation, is undergoing its first revision since 1996. In this talk, we place this test standard into context with other relevant radiation test standards to show its importance for single-event effect radiation testing for space applications. We show the range of industry, government, and end-user party involvement in the revision. Finally, we highlight some of the key changes being made and discuss the trade-space in which setting standards must be made to be both useful and broadly adopted.
78 FR 44189 - Petition for Modification of Single Car Air Brake Test Procedures
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-23
...] Petition for Modification of Single Car Air Brake Test Procedures In accordance with Part 232 of Title 49... Administration (FRA) per 49 CFR 232.307 to modify the single car air brake test procedures located in AAR Standard S-486, Code of Air Brake System Tests for Freight Equipment-- Single Car Test, and required...
Flight Instructor Practical Test Standards for Airplane - Single-engine, Multiengine
DOT National Transportation Integrated Search
1991-05-01
The Flight Instructor - Airplane Practical Test Standards book has been : published by the Federal Aviation Administration (FAA) to establish the : standards for the flight instructor certification practical tests for the : airplane category and the ...
Private Pilot Practical Test Standards for Airplane (SEL, MEL, SES, MES)
DOT National Transportation Integrated Search
1995-05-01
The Private Pilot - Airplane Practical Test Standards book has been : published by the Federal Aviation Administration (FAA) to establish the : standards for the private pilot certification practical tests for the airplane : category and the single-e...
Capacitance discharge system for ignition of Single Bridge Apollo Standard Initiators (SBASI)
NASA Technical Reports Server (NTRS)
Ward, R. D.
1974-01-01
The design support data developed during the single bridge Apollo standard initiator (SBASI) program are presented. A circuit was designed and bread-board tested to verify operational capabilities of the circuit. Test data, design criteria, weight, and reliability trade-off considerations, and final design recommendations are reported.
Status of Photovoltaic Calibration and Measurement Standards
NASA Technical Reports Server (NTRS)
Baraona, Cosmo; Bailey, Sheila; Curtis, Henry; Brinker, David; Jenkins, Phillip; Scheiman, David
2001-01-01
The 7th International Workshop on Space Solar Cell Calibration and Measurement was held on September 25-27, 2000 in Girdwood, Alaska. Representatives from eight countries discussed international standards for single and multijunction solar cell measurement and calibration methods, round robin intercomparisons, and irradiation test methods for space solar cells. Progress toward adoption of an ISO standard on single junction cells was made. Agreement was reached to begin work on new standards for multijunction cells and irradiation testing. Progress on present single junction round robin measurements was discussed and future multijunction round robins were planned. The next workshop will be held in Germany in October 2001.
Willmes, K
1985-08-01
Methods for the analysis of a single subject's test profile(s) proposed by Huber (1973) are applied to the Aachen Aphasia Test (AAT). The procedures are based on the classical test theory model (Lord & Novick, 1968) and are suited for any (achievement) test with standard norms from a large standardization sample and satisfactory reliability estimates. Two test profiles of a Wernicke's aphasic, obtained before and after a 3-month period of speech therapy, are analyzed using inferential comparisons between (groups of) subtest scores on one test application and between two test administrations for single (groups of) subtests. For each of these comparisons, the two aspects of (i) significant (reliable) differences in performance beyond measurement error and (ii) the diagnostic validity of that difference in the reference population of aphasic patients are assessed. Significant differences between standardized subtest scores and a remarkably better preserved reading and writing ability could be found for both test administrations using the multiple test procedure of Holm (1979). Comparison of both profiles revealed an overall increase in performance for each subtest as well as changes in level of performance relations between pairs of subtests.
NASA Technical Reports Server (NTRS)
Lauenstein, Jean-Marie
2016-01-01
The JEDEC JESD57 test standard, Procedures for the Measurement of Single-Event Effects in Semiconductor Devices from Heavy-Ion Irradiation, is undergoing its first revision since 1996. This presentation will provide an overview of some of the key proposed updates to the document.
NASA Technical Reports Server (NTRS)
Barclay, D. L.
1980-01-01
Results of an experimental program to develop several types of graphite/polyimide (GR/PI) bonded and bolted joints for lightly loaded flight components for advanced space transportation systems and high speed aircraft are presented. Tasks accomplished include: a literature survey; design of static discriminator specimens; design allowables testing; fabrication of test panels and specimens; small specimen testing; and standard joint testing. Detail designs of static discriminator specimens for each of the four major attachment types are presented. Test results are given for the following: (1) transverse tension of Celion 3000/PMR-15 laminate; (2) net tension of a laminate for both a loaded and unloaded bolt hole; (3) comparative testing of bonded and co-cured doublers along with pull-off tests of single and double bonded angles; (4) single lap shear tests, transverse tension and coefficient of thermal expansion tests of A7F (LARC-13 amide-imide modified) adhesive; and (5) tension tests of standard single lap, double lap, and symmetric step lap bonded joints. Also, included are results of a finite element analysis of a single lap bonded composite joint.
Electronic delay ignition module for single bridgewire Apollo standard initiator
NASA Technical Reports Server (NTRS)
Ward, R. D.
1975-01-01
An engineering model and a qualification model of the EDIM were constructed and tested to Scout flight qualification criteria. The qualification model incorporated design improvements resulting from the engineering model tests. Compatibility with single bridgewire Apollo standard initiator (SBASI) was proven by test firing forty-five (45) SBASI's with worst case voltage and temperature conditions. The EDIM was successfully qualified for Scout flight application with no failures during testing of the qualification unit. Included is a method of implementing the EDIM into Scout vehicle hardware and the ground support equipment necessary to check out the system.
Preparation of calibrated test packages for particle impact noise detection
NASA Technical Reports Server (NTRS)
1977-01-01
A standard calibration method for any particle impact noise detection (PIND) test system used to detect loose particles responsible for failures in hybrid circuits was developed along with a procedure for preparing PIND standard test devices. Hybrid packages were seeded with a single gold ball, hermetically sealed, leak tested, and PIND tested. Conclusions are presented.
Nitrous oxide as a tracer gas in the ASHRAE 110-1995 Standard.
Burke, Martin; Wong, Larry; Gonzales, Ben A; Knutson, Gerhard
2014-01-01
ANSI/ASHRAE Standard 110 provides a quantitative method for testing the performance of laboratory fume hoods. Through release of a known quantity (4.0 Lpm) of a tracer gas, and subsequent monitoring of the tracer gas concentration in the "breathing zone" of a mannequin positioned in front of the hood, this method allows for evaluation of laboratory hood performance. Standard 110 specifies sulfur hexafluoride (SF6) as the tracer gas; however, suitable alternatives are allowed. Through three series of performance tests, this analysis serves to investigate the use of nitrous oxide (N2O) as an alternate tracer gas for hood performance testing. Single gas tests were performed according to ASHRAE Standard 110-1995 with each tracer gas individually. These tests showed identical results using an acceptance criterion of AU 0.1 with the sash half open, nominal 18 inches (0.46m) high, and the face velocity at a nominal 60 fpm (0.3 m/s). Most data collected in these single gas tests, for both tracer gases, were below the minimum detection limit, thus two dual gas tests were developed for simultaneous sampling of both tracer gases. Dual gas dual ejector tests were performed with both tracer gases released simultaneously through two ejectors, and the concentration measured with two detectors using a common sampling probe. Dual gas single ejector tests were performed with both tracer gases released though a single ejector, and the concentration measured in the same manner as the dual gas dual ejector tests. The dual gas dual ejector tests showed excellent correlation, with R typically greater than 0.9. Variance was observed in the resulting regression line for each hood, likely due to non-symmetry between the two challenges caused by variables beyond the control of the investigators. Dual gas single ejector tests resulted in exceptional correlation, with R>0.99 typically for the consolidated data, with a slope of 1.0. These data indicate equivalent results for ASHRAE 110 performance testing using either SF6 or N2O, indicating N2O as an applicable alternate tracer gas.
NASA Technical Reports Server (NTRS)
Ratcliffe, James G.
2010-01-01
This paper details part of an effort focused on the development of a standardized facesheet/core peel debonding test procedure. The purpose of the test is to characterize facesheet/core peel in sandwich structure, accomplished through the measurement of the critical strain energy release rate associated with the debonding process. The specific test method selected for the standardized test procedure utilizes a single cantilever beam (SCB) specimen configuration. The objective of the current work is to develop a method for establishing SCB specimen dimensions. This is achieved by imposing specific limitations on specimen dimensions, with the objectives of promoting a linear elastic specimen response, and simplifying the data reduction method required for computing the critical strain energy release rate associated with debonding. The sizing method is also designed to be suitable for incorporation into a standardized test protocol. Preliminary application of the resulting sizing method yields practical specimen dimensions.
Air Force Officer Qualifying Test Form O: Development and Standardization.
ERIC Educational Resources Information Center
Rogers, Deborah L.; And Others
This report presents the rationale, development, and standardization of the Air Force Officer Qualifying Test (AFOQT) Form O. The test is used to select individuals for officer commissioning programs, and candidates for pilot and navigator training. Form O contains 380 items organized in 16 subtests. All items are administered in a single test…
NASA Technical Reports Server (NTRS)
Ratcliffe, James G.
2010-01-01
This technical publication details part of an effort focused on the development of a standardized facesheet/core peel debonding test procedure. The purpose of the test is to characterize facesheet/core peel in sandwich structure, accomplished through the measurement of the critical strain energy release rate associated with the debonding process. Following an examination of previously developed tests and a recent evaluation of a selection of these methods, a single cantilever beam (SCB) specimen was identified as being a promising candidate for establishing such a standardized test procedure. The objective of the work described here was to begin development of a protocol for conducting a SCB test that will render the procedure suitable for standardization. To this end, a sizing methodology was developed to ensure appropriate SCB specimen dimensions are selected for a given sandwich system. Application of this method to actual sandwich systems yielded SCB specimen dimensions that would be practical for use. This study resulted in the development of a practical SCB specimen sizing method, which should be well-suited for incorporation into a standardized testing protocol.
Toward Joint Hypothesis-Tests Seismic Event Screening Analysis: Ms|mb and Event Depth
DOE Office of Scientific and Technical Information (OSTI.GOV)
Anderson, Dale; Selby, Neil
2012-08-14
Well established theory can be used to combine single-phenomenology hypothesis tests into a multi-phenomenology event screening hypothesis test (Fisher's and Tippett's tests). Commonly used standard error in Ms:mb event screening hypothesis test is not fully consistent with physical basis. Improved standard error - Better agreement with physical basis, and correctly partitions error to include Model Error as a component of variance, correctly reduces station noise variance through network averaging. For 2009 DPRK test - Commonly used standard error 'rejects' H0 even with better scaling slope ({beta} = 1, Selby et al.), improved standard error 'fails to rejects' H0.
1984-01-01
structural system the orthodontic appliance consists intraorally of bands or bonded pads and the attached brackets , the arch wires, the ligatures, and any...RD-Ali5B 994 STRUCTURAL PROPERTIES OF SINGLE-STRAND ORTHODONTIC i/i WIRES FROM A PROPOSED__(U) AIR FORCE INST OF TECH WRIGHT-PATTERSON RFB OH M L... Orthodontic Wires From A Proposed Alternative - Standard Flexure Test 6. PERPOMING o1. REPORT NUMBER AUTNOR(e) I. CONTRACT O& GRANT NUMUER(a) Marion L
Aithal, Venkatesh; Kei, Joseph; Driscoll, Carlie; Murakoshi, Michio; Wada, Hiroshi
2018-02-01
Diagnosing conductive conditions in newborns is challenging for both audiologists and otolaryngologists. Although high-frequency tympanometry (HFT), acoustic stapedial reflex tests, and wideband absorbance measures are useful diagnostic tools, there is performance measure variability in their detection of middle ear conditions. Additional diagnostic sensitivity and specificity measures gained through new technology such as sweep frequency impedance (SFI) measures may assist in the diagnosis of middle ear dysfunction in newborns. The purpose of this study was to determine the test performance of SFI to predict the status of the outer and middle ear in newborns against commonly used reference standards. Automated auditory brainstem response (AABR), HFT (1000 Hz), transient evoked otoacoustic emission (TEOAE), distortion product otoacoustic emission (DPOAE), and SFI tests were administered to the study sample. A total of 188 neonates (98 males and 90 females) with a mean gestational age of 39.4 weeks were included in the sample. Mean age at the time of testing was 44.4 hr. Diagnostic accuracy of SFI was assessed in terms of its ability to identify conductive conditions in neonates when compared with nine different reference standards (including four single tests [AABR, HFT, TEOAE, and DPOAE] and five test batteries [HFT + DPOAE, HFT + TEOAE, DPOAE + TEOAE, DPOAE + AABR, and TEOAE + AABR]), using receiver operating characteristic (ROC) analysis and traditional test performance measures such as sensitivity and specificity. The test performance of SFI against the test battery reference standard of HFT + DPOAE and single reference standard of HFT was high with an area under the ROC curve (AROC) of 0.87 and 0.82, respectively. Although the HFT + DPOAE test battery reference standard performed better than the HFT reference standard in predicting middle ear conductive conditions in neonates, the difference in AROC was not significant. Further analysis revealed that the highest sensitivity and specificity for SFI (86% and 88%, respectively) was obtained when compared with the reference standard of HFT + DPOAE. Among the four single reference standards, SFI had the highest sensitivity and specificity (76% and 88%, respectively) when compared against the HFT reference standard. The high test performance of SFI against the HFT and HFT + DPOAE reference standards indicates that the SFI measure has appropriate diagnostic accuracy in detection of conductive conditions in newborns. Hence, the SFI test could be used as adjunct tool to identify conductive conditions in universal newborn hearing screening programs, and can also be used in diagnostic follow-up assessments. American Academy of Audiology
Bartoli, Francesco; Crocamo, Cristina; Biagi, Enrico; Di Carlo, Francesco; Parma, Francesca; Madeddu, Fabio; Capuzzi, Enrico; Colmegna, Fabrizia; Clerici, Massimo; Carrà, Giuseppe
2016-08-01
There is a lack of studies testing accuracy of fast screening methods for alcohol use disorder in mental health settings. We aimed at estimating clinical utility of a standard single-item test for case finding and screening of DSM-5 alcohol use disorder among individuals suffering from anxiety and mood disorders. We recruited adults consecutively referred, in a 12-month period, to an outpatient clinic for anxiety and depressive disorders. We assessed the National Institute on Alcohol Abuse and Alcoholism (NIAAA) single-item test, using the Mini- International Neuropsychiatric Interview (MINI), plus an additional item of Composite International Diagnostic Interview (CIDI) for craving, as reference standard to diagnose a current DSM-5 alcohol use disorder. We estimated sensitivity and specificity of the single-item test, as well as positive and negative Clinical Utility Indexes (CUIs). 242 subjects with anxiety and mood disorders were included. The NIAAA single-item test showed high sensitivity (91.9%) and specificity (91.2%) for DSM-5 alcohol use disorder. The positive CUI was 0.601, whereas the negative one was 0.898, with excellent values also accounting for main individual characteristics (age, gender, diagnosis, psychological distress levels, smoking status). Testing for relevant indexes, we found an excellent clinical utility of the NIAAA single-item test for screening true negative cases. Our findings support a routine use of reliable methods for rapid screening in similar mental health settings. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Diagnostic Profiles: A Standard Setting Method for Use with a Cognitive Diagnostic Model
ERIC Educational Resources Information Center
Skaggs, Gary; Hein, Serge F.; Wilkins, Jesse L. M.
2016-01-01
This article introduces the Diagnostic Profiles (DP) standard setting method for setting a performance standard on a test developed from a cognitive diagnostic model (CDM), the outcome of which is a profile of mastered and not-mastered skills or attributes rather than a single test score. In the DP method, the key judgment task for panelists is a…
NASA Technical Reports Server (NTRS)
Reddell, Brandon D.; Bailey, Charles R.; Nguyen, Kyson V.; O'Neill, Patrick M.; Wheeler, Scott; Gaza, Razvan; Cooper, Jaime; Kalb, Theodore; Patel, Chirag; Beach, Elden R.;
2017-01-01
We present the results of Single Event Effects (SEE) testing with high energy protons and with low and high energy heavy ions for electrical components considered for Low Earth Orbit (LEO) and for deep space applications.
Noble, R T; Moore, D F; Leecaster, M K; McGee, C D; Weisberg, S B
2003-04-01
In July 1999, California's ocean recreational bacterial water quality standards were changed from a total coliform (TC) test to a standard requiring testing for all three bacterial indicators: TC, fecal coliforms (FC), and enterococci (EC). To compare the relationship between the bacterial indicators, and the effect that changing the standards would have on recreational water regulatory actions, three regional studies were conducted along the southern California shoreline from Santa Barbara to San Diego, California. Two studies were conducted during dry weather and one following a large storm event. In each study, samples were collected at over 200 sites which were selected using a stratified random design, with strata consisting of open beach areas and rocky shoreline, and areas near freshwater outlets that drain land-based runoff. During the dry weather studies, samples were collected once per week for 5 weeks. For the storm event study, sampling occurred on a single day about 24 h following the storm. The three indicator bacteria were measured at each site and the results were compared to the single sample standards (TC > 10,000; FC > 400 and EC > 104 MPN or cfu/100 ml). EC was the indicator that failed the single sample standards most often. During the wet weather study, 99% of all standard failures were detected using EC, compared with only 56% for FC, and 40% for TC. During the Summer Study, EC was again the indicator that failed the single sample standards most often, with 60% of the failures for EC alone. The increased failure of the EC standard occurred consistently regardless of whether the sample was collected at a beach or rocky shoreline site, or at a site near a freshwater outlet. Agreement among indicators was better during wet weather than during dry weather. During dry weather, agreement among indicators was better near freshwater outlets than along open shoreline. Cumulatively, our results suggest that replacement of a TC standard with an EC standard will lead to a five-fold increase in failures during dry weather and a doubling of failures during wet weather. Replacing a TC standard with one based on all three indicators will lead to an eight-fold increase in failures. Changes in the requirements for water quality testing have strong implications for increases in beach closures and restrictions. Copyright 2002 Elsevier Science Ltd.
Hoyer, Annika; Kuss, Oliver
2018-05-01
Meta-analysis of diagnostic studies is still a rapidly developing area of biostatistical research. Especially, there is an increasing interest in methods to compare different diagnostic tests to a common gold standard. Restricting to the case of two diagnostic tests, in these meta-analyses the parameters of interest are the differences of sensitivities and specificities (with their corresponding confidence intervals) between the two diagnostic tests while accounting for the various associations across single studies and between the two tests. We propose statistical models with a quadrivariate response (where sensitivity of test 1, specificity of test 1, sensitivity of test 2, and specificity of test 2 are the four responses) as a sensible approach to this task. Using a quadrivariate generalized linear mixed model naturally generalizes the common standard bivariate model of meta-analysis for a single diagnostic test. If information on several thresholds of the tests is available, the quadrivariate model can be further generalized to yield a comparison of full receiver operating characteristic (ROC) curves. We illustrate our model by an example where two screening methods for the diagnosis of type 2 diabetes are compared.
NASA Astrophysics Data System (ADS)
Sperling, A.; Meyer, M.; Pendsa, S.; Jordan, W.; Revtova, E.; Poikonen, T.; Renoux, D.; Blattner, P.
2018-04-01
Proper characterization of test setups used in industry for testing and traceable measurement of lighting devices by the substitution method is an important task. According to new standards for testing LED lamps, luminaires and modules, uncertainty budgets are requested because in many cases the properties of the device under test differ from the transfer standard used, which may cause significant errors, for example if a LED-based lamp is tested or calibrated in an integrating sphere which was calibrated with a tungsten lamp. This paper introduces a multiple transfer standard, which was designed not only to transfer a single calibration value (e.g. luminous flux) but also to characterize test setups used for LED measurements with additional provided and calibrated output features to enable the application of the new standards.
Standard Methods for Bolt-Bearing Testing of Textile Composites
NASA Technical Reports Server (NTRS)
Portanova, M. A.; Masters, J. E.
1995-01-01
The response of three 2-D braided materials to bolt bearing loading was evaluated using data generated by Boeing Defense and Space Group in Philadelphia, PA. Three test methods, stabilized single shear, unstabilized single shear, and double shear, were compared. In general, these textile composites were found to be sensitive to bolt bearing test methods. The stabilized single shear method yielded higher strengths than the unstabilized single shear method in all cases. The double shear test method always produced the highest strengths but these results may be somewhat misleading. It is therefore recommended that standard material comparisons be made using the stabilized single shear test method. The effects of two geometric parameters, W/D and e/D, were also studied. An evaluation of the effect of the specimen width (W) to hole diameter (D) ratio concluded that bolt bearing responses were consistent with open hole tension results. A W/D ratio of 6 or greater should be maintained. The proximity of the hole to the specimen edge significantly affected strength. In all cases, strength was improved by increasing the ratio of the distance from the hole center to the specimen edge (e) to the hole diameter (D) above 2. An e/D ratio of 3 or greater is recommended.
The Development and Validation of the Test Of Astronomy STandards (TOAST)
ERIC Educational Resources Information Center
Slater, Stephanie J.
2014-01-01
The Test Of Astronomy STandards (TOAST) is a comprehensive assessment instrument designed to measure students' general astronomy content knowledge. Built upon the research embedded within a generation of astronomy assessments designed to measure single concepts, the TOAST is appropriate to measure across an entire astronomy course. The TOAST's…
Alcorn, S.W.; Pascho, R.J.
2000-01-01
An enzyme-linked immunosorbent assay (ELISA) was developed on the basis of testing a single dilution of serum to quantify the level of antibody to the p57 protein of Renibaclerium salmoninarum in sockeye salmon (Oncorhynchus nerka). The levels of antibody were interpolated from a standard curve constructed by relating the optical densities (OD) produced by several dilutions of a high-titer rainbow trout (O. mykiss) antiserum to the p57 protein. The ELISA OD values produced by as many as 36 test sera on each microplate were compared with the standard curve to calculate the antigen-specific antibody activity. Repeated measurements of 36 samples on 3 microplates on each of 6 assay dates indicated that the mean intraassay coefficient of variation (CV) was 6.68% (range, 0-23%) and the mean interassay CV was 8.29% (range, 4-16%). The antibody levels determined for the serum sample from 24 sockeye salmon vaccinated with a recombinant p57 protein generally were correlated with the levels determined by endpoint titration (r2 = 0.936) and with results from another ELISA that was based on extrapolation of antibody levels from a standard curve (r2 = 0.956). The single-dilution antibody ELISA described here increases the number of samples that can be tested on each microplate compared with immunoassays based on analysis of several dilutions of each test serum. It includes controls for interassay standardization and can be used to test fish weighing <3 g.
Computing tools for implementing standards for single-case designs.
Chen, Li-Ting; Peng, Chao-Ying Joanne; Chen, Ming-E
2015-11-01
In the single-case design (SCD) literature, five sets of standards have been formulated and distinguished: design standards, assessment standards, analysis standards, reporting standards, and research synthesis standards. This article reviews computing tools that can assist researchers and practitioners in meeting the analysis standards recommended by the What Works Clearinghouse: Procedures and Standards Handbook-the WWC standards. These tools consist of specialized web-based calculators or downloadable software for SCD data, and algorithms or programs written in Excel, SAS procedures, SPSS commands/Macros, or the R programming language. We aligned these tools with the WWC standards and evaluated them for accuracy and treatment of missing data, using two published data sets. All tools were tested to be accurate. When missing data were present, most tools either gave an error message or conducted analysis based on the available data. Only one program used a single imputation method. This article concludes with suggestions for an inclusive computing tool or environment, additional research on the treatment of missing data, and reasonable and flexible interpretations of the WWC standards. © The Author(s) 2015.
Inter-rater reliability of three standardized functional tests in patients with low back pain
Tidstrand, Johan; Horneij, Eva
2009-01-01
Background Of all patients with low back pain, 85% are diagnosed as "non-specific lumbar pain". Lumbar instability has been described as one specific diagnosis which several authors have described as delayed muscular responses, impaired postural control as well as impaired muscular coordination among these patients. This has mostly been measured and evaluated in a laboratory setting. There are few standardized and evaluated functional tests, examining functional muscular coordination which are also applicable in the non-laboratory setting. In ordinary clinical work, tests of functional muscular coordination should be easy to apply. The aim of this present study was to therefore standardize and examine the inter-rater reliability of three functional tests of muscular functional coordination of the lumbar spine in patients with low back pain. Methods Nineteen consecutive individuals, ten men and nine women were included. (Mean age 42 years, SD ± 12 yrs). Two independent examiners assessed three tests: "single limb stance", "sitting on a Bobath ball with one leg lifted" and "unilateral pelvic lift" on the same occasion. The standardization procedure took altered positions of the spine or pelvis and compensatory movements of the free extremities into account. The inter-rater reliability was analyzed by Cohen's kappa coefficient (κ) and by percentage agreement. Results The inter-rater reliability for the right and the left leg respectively was: for the single limb stance very good (κ: 0.88–1.0), for sitting on a Bobath ball good (κ: 0.79) and very good (κ: 0.88) and for the unilateral pelvic lift: good (κ: 0.61) and moderate (κ: 0.47). Conclusion The present study showed good to very good inter-rater reliability for two standardized tests, that is, the single-limb stance and sitting on a Bobath-ball with one leg lifted. Inter-rater reliability for the unilateral pelvic lift test was moderate to good. Validation of the tests in their ability to evaluate lumbar stability is required. PMID:19490644
46 CFR 164.023-7 - Performance; non-standard thread.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 6 2010-10-01 2010-10-01 false Performance; non-standard thread. 164.023-7 Section 164... Performance; non-standard thread. (a) Use Codes 1, 2, 3, 4BC, 4RB, 5 (any). Each non-standard thread which...) testing machine. (2) Single strand breaking strength (after weathering). After exposure in a sunshine...
46 CFR 164.023-7 - Performance; non-standard thread.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 6 2011-10-01 2011-10-01 false Performance; non-standard thread. 164.023-7 Section 164... Performance; non-standard thread. (a) Use Codes 1, 2, 3, 4BC, 4RB, 5 (any). Each non-standard thread which...) testing machine. (2) Single strand breaking strength (after weathering). After exposure in a sunshine...
NASA Technical Reports Server (NTRS)
Scheick, Leif
2011-01-01
Single-event-effect test results for hi-rel total-dose-hardened power MOSFETs are presented in this report. TheSCF9550 from Semicoa and the IRHM57260SE from International Rectifier were tested to NASA test condition/standards and requirements.The IRHM57260SE performed much better when compared to previous testing. These initial results confirm that parts from the Temecula line are marginally comparable to the El Segundo line. The SCF9550 from Semicoa was also tested and represents the initial parts offering from this vendor. Both parts experienced single-event gate rupture (SEGR) and single-event burnout (SEB). All of the SEGR was from gate to drain.
Analysis of household refrigerators for different testing standards
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bansal, P.K.; McGill, I.
This study highlights the salient differences among various testing standards for household refrigerator-freezers and proposes a methodology for predicting the performance of a single evaporator-based vapor-compression refrigeration system (either refrigerator or freezer) from one test standard (where the test data are available-the reference case) to another (the alternative case). The standards studied during this investigation include the Australian-New Zealand Standard (ANZS), the International Standard (ISO), the American National Standard (ANSI), the Japanese Industrial Standard (JIS), and the Chinese National Standard (CNS). A simple analysis in conjunction with the BICYCLE model (Bansal and Rice 1993) is used to calculate the energymore » consumption of two refrigerator cabinets from the reference case to the alternative cases. The proposed analysis includes the effect of door openings (as required by the JIS) as well as defrost heaters. The analytical results are found to agree reasonably well with the experimental observations for translating energy consumption information from one standard to another.« less
Automotive Lubricant Specification and Testing
NASA Astrophysics Data System (ADS)
Fox, M. F.
This chapter concerns commercial lubricant specification and testing, drawing together the many themes of previous chapters. Military lubricant standards were a very strong initial influence during World War II and led to the separate historical development of the North American and European specification systems. The wide range of functions that a successful lubricant must satisfy is discussed, together with issues of balancing special or universal applications, single or multiple engine tests, the philosophy of accelerated testing and the question of 'who sets the standards?' The role of engine tests and testing organisations is examined.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yuan, Lulin, E-mail: lulin.yuan@duke.edu; Wu, Q. Jackie; Yin, Fang-Fang
2014-02-15
Purpose: Sparing of single-side parotid gland is a common practice in head-and-neck (HN) intensity modulated radiation therapy (IMRT) planning. It is a special case of dose sparing tradeoff between different organs-at-risk. The authors describe an improved mathematical model for predicting achievable dose sparing in parotid glands in HN IMRT planning that incorporates single-side sparing considerations based on patient anatomy and learning from prior plan data. Methods: Among 68 HN cases analyzed retrospectively, 35 cases had physician prescribed single-side parotid sparing preferences. The single-side sparing model was trained with cases which had single-side sparing preferences, while the standard model was trainedmore » with the remainder of cases. A receiver operating characteristics (ROC) analysis was performed to determine the best criterion that separates the two case groups using the physician's single-side sparing prescription as ground truth. The final predictive model (combined model) takes into account the single-side sparing by switching between the standard and single-side sparing models according to the single-side sparing criterion. The models were tested with 20 additional cases. The significance of the improvement of prediction accuracy by the combined model over the standard model was evaluated using the Wilcoxon rank-sum test. Results: Using the ROC analysis, the best single-side sparing criterion is (1) the predicted median dose of one parotid is higher than 24 Gy; and (2) that of the other is higher than 7 Gy. This criterion gives a true positive rate of 0.82 and a false positive rate of 0.19, respectively. For the bilateral sparing cases, the combined and the standard models performed equally well, with the median of the prediction errors for parotid median dose being 0.34 Gy by both models (p = 0.81). For the single-side sparing cases, the standard model overestimates the median dose by 7.8 Gy on average, while the predictions by the combined model differ from actual values by only 2.2 Gy (p = 0.005). Similarly, the sum of residues between the modeled and the actual plan DVHs is the same for the bilateral sparing cases by both models (p = 0.67), while the standard model predicts significantly higher DVHs than the combined model for the single-side sparing cases (p = 0.01). Conclusions: The combined model for predicting parotid sparing that takes into account single-side sparing improves the prediction accuracy over the previous model.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yuan, Lulin, E-mail: lulin.yuan@duke.edu; Wu, Q. Jackie; Yin, Fang-Fang
Purpose: Sparing of single-side parotid gland is a common practice in head-and-neck (HN) intensity modulated radiation therapy (IMRT) planning. It is a special case of dose sparing tradeoff between different organs-at-risk. The authors describe an improved mathematical model for predicting achievable dose sparing in parotid glands in HN IMRT planning that incorporates single-side sparing considerations based on patient anatomy and learning from prior plan data. Methods: Among 68 HN cases analyzed retrospectively, 35 cases had physician prescribed single-side parotid sparing preferences. The single-side sparing model was trained with cases which had single-side sparing preferences, while the standard model was trainedmore » with the remainder of cases. A receiver operating characteristics (ROC) analysis was performed to determine the best criterion that separates the two case groups using the physician's single-side sparing prescription as ground truth. The final predictive model (combined model) takes into account the single-side sparing by switching between the standard and single-side sparing models according to the single-side sparing criterion. The models were tested with 20 additional cases. The significance of the improvement of prediction accuracy by the combined model over the standard model was evaluated using the Wilcoxon rank-sum test. Results: Using the ROC analysis, the best single-side sparing criterion is (1) the predicted median dose of one parotid is higher than 24 Gy; and (2) that of the other is higher than 7 Gy. This criterion gives a true positive rate of 0.82 and a false positive rate of 0.19, respectively. For the bilateral sparing cases, the combined and the standard models performed equally well, with the median of the prediction errors for parotid median dose being 0.34 Gy by both models (p = 0.81). For the single-side sparing cases, the standard model overestimates the median dose by 7.8 Gy on average, while the predictions by the combined model differ from actual values by only 2.2 Gy (p = 0.005). Similarly, the sum of residues between the modeled and the actual plan DVHs is the same for the bilateral sparing cases by both models (p = 0.67), while the standard model predicts significantly higher DVHs than the combined model for the single-side sparing cases (p = 0.01). Conclusions: The combined model for predicting parotid sparing that takes into account single-side sparing improves the prediction accuracy over the previous model.« less
ERIC Educational Resources Information Center
Gu, Lin; Lockwood, John; Powers, Donald E.
2015-01-01
Standardized tests are often designed to provide only a snapshot of test takers' knowledge, skills, or abilities at a single point in time. Sometimes, however, they are expected to serve more demanding functions, one of them is assessing change in knowledge, skills, or ability over time because of learning effects.The latter is the case for the…
ERIC Educational Resources Information Center
Strauss, Gregory P.; Allen, Daniel N.; Jorgensen, Melinda L.; Cramer, Stacey L.
2005-01-01
Previous studies have examined the reliability of scores derived from various Stroop tasks. However, few studies have compared reliability of more recently developed Stroop variants such as emotional Stroop tasks to standard versions of the Stroop. The current study developed four different single-stimulus Stroop tasks and compared test-retest…
42 CFR 493.643 - Fee for determination of program compliance.
Code of Federal Regulations, 2010 CFR
2010-10-01
... laboratory's scope and volume of testing (excluding tests performed for quality control, quality assurance... procedure or examination for a single analyte. (Tests performed for quality control, quality assurance, and... HUMAN SERVICES (CONTINUED) STANDARDS AND CERTIFICATION LABORATORY REQUIREMENTS General Administration...
Harikesavan, Karvannan; Chakravarty, Raj D; Maiya, Arun G; Hegde, Sanjay P; Y Shivanna, Shivakumar
2017-01-01
Total knee replacement (TKR) is the commonest surgical procedure for patients with severe pain and impaired physical function following end stage knee osteoarthritis. The hip abductors are well renowned in stabilization of the trunk and hip during walking, maintaining the lower limb position, and transferring the forces from the lower limbs to the pelvis. To assess the efficacy of hip abductor strengthening exercise on functional outcome using performance based outcome measures following total knee replacement. An observer blinded randomized pilot trial design was conducted at Manipal hospital, Bangalore, India. Participants designated for elective TKR were randomized to experimental group hip abductor strengthening along with standard rehabilitation (n=10) or control group standard rehabilitation alone (n=10). Participants followed for one year to assess physical function using performance based outcomes, such as timed up and go test, single leg stance test, six minute walk test, knee extensor strength and hip abductor strength. Eighteen participants with a mean age of 63.1 ± 5.5 years (8 Males and 10 Females) completed the study. Improvement in hip abduction strength, single leg stand test was superior in hip abductor strengthening group at 3 months and 1 year when compared to standard rehabilitation alone. Hip abductor strengthening showed superior improvements in single leg stance test and six minute walk test. Hip abductor strengthening exercises has the potential to improve physical function following total knee replacement.
Harikesavan, Karvannan; Chakravarty, Raj D.; Maiya, Arun G; Hegde, Sanjay P.; Y. Shivanna, Shivakumar
2017-01-01
Background: Total knee replacement (TKR) is the commonest surgical procedure for patients with severe pain and impaired physical function following end stage knee osteoarthritis. The hip abductors are well renowned in stabilization of the trunk and hip during walking, maintaining the lower limb position, and transferring the forces from the lower limbs to the pelvis. Objective: To assess the efficacy of hip abductor strengthening exercise on functional outcome using performance based outcome measures following total knee replacement. Methods: An observer blinded randomized pilot trial design was conducted at Manipal hospital, Bangalore, India. Participants designated for elective TKR were randomized to experimental group hip abductor strengthening along with standard rehabilitation (n=10) or control group standard rehabilitation alone (n=10). Participants followed for one year to assess physical function using performance based outcomes, such as timed up and go test, single leg stance test, six minute walk test, knee extensor strength and hip abductor strength. Result: Eighteen participants with a mean age of 63.1 ± 5.5 years (8 Males and 10 Females) completed the study. Improvement in hip abduction strength, single leg stand test was superior in hip abductor strengthening group at 3 months and 1 year when compared to standard rehabilitation alone. Conclusion: Hip abductor strengthening showed superior improvements in single leg stance test and six minute walk test. Hip abductor strengthening exercises has the potential to improve physical function following total knee replacement. PMID:28567148
Storey, Helen L.; Huang, Ying; Crudder, Chris; Golden, Allison; de los Santos, Tala; Hawkins, Kenneth
2015-01-01
Novel typhoid diagnostics currently under development have the potential to improve clinical care, surveillance, and the disease burden estimates that support vaccine introduction. Blood culture is most often used as the reference method to evaluate the accuracy of new typhoid tests; however, it is recognized to be an imperfect gold standard. If no single gold standard test exists, use of a composite reference standard (CRS) can improve estimation of diagnostic accuracy. Numerous studies have used a CRS to evaluate new typhoid diagnostics; however, there is no consensus on an appropriate CRS. In order to evaluate existing tests for use as a reference test or inclusion in a CRS, we performed a systematic review of the typhoid literature to include all index/reference test combinations observed. We described the landscape of comparisons performed, showed results of a meta-analysis on the accuracy of the more common combinations, and evaluated sources of variability based on study quality. This wide-ranging meta-analysis suggests that no single test has sufficiently good performance but some existing diagnostics may be useful as part of a CRS. Additionally, based on findings from the meta-analysis and a constructed numerical example demonstrating the use of CRS, we proposed necessary criteria and potential components of a typhoid CRS to guide future recommendations. Agreement and adoption by all investigators of a standardized CRS is requisite, and would improve comparison of new diagnostics across independent studies, leading to the identification of a better reference test and improved confidence in prevalence estimates. PMID:26566275
21 CFR 660.33 - Testing of source material.
Code of Federal Regulations, 2011 CFR
2011-04-01
...) BIOLOGICS ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Reagent Red Blood Cells § 660... incorporated into the Reagent Red Blood Cell product shall be individually tested, with no fewer than two donor... tests for each factor. The Reagent Red Blood Cell product may be tested with a single donor source of...
21 CFR 660.33 - Testing of source material.
Code of Federal Regulations, 2012 CFR
2012-04-01
...) BIOLOGICS ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Reagent Red Blood Cells § 660... incorporated into the Reagent Red Blood Cell product shall be individually tested, with no fewer than two donor... tests for each factor. The Reagent Red Blood Cell product may be tested with a single donor source of...
21 CFR 660.33 - Testing of source material.
Code of Federal Regulations, 2014 CFR
2014-04-01
...) BIOLOGICS ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Reagent Red Blood Cells § 660... incorporated into the Reagent Red Blood Cell product shall be individually tested, with no fewer than two donor... tests for each factor. The Reagent Red Blood Cell product may be tested with a single donor source of...
21 CFR 660.33 - Testing of source material.
Code of Federal Regulations, 2013 CFR
2013-04-01
...) BIOLOGICS ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Reagent Red Blood Cells § 660... incorporated into the Reagent Red Blood Cell product shall be individually tested, with no fewer than two donor... tests for each factor. The Reagent Red Blood Cell product may be tested with a single donor source of...
21 CFR 660.33 - Testing of source material.
Code of Federal Regulations, 2010 CFR
2010-04-01
...) BIOLOGICS ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Reagent Red Blood Cells § 660... incorporated into the Reagent Red Blood Cell product shall be individually tested, with no fewer than two donor... tests for each factor. The Reagent Red Blood Cell product may be tested with a single donor source of...
The Effect of Font Selection on Student Test Anxiety
ERIC Educational Resources Information Center
Murphy, Peter V.
2014-01-01
The emergence of standards-based curriculums has resulted in an increased frequency of student testing, including high-stakes testing. Of students who take tests, up to 65% may experience test anxiety, which can have negative effects on student outcomes. For this reason, the purpose of this single-group, repeated measures design, quantitative…
A single-question screening test for drug use in primary care.
Smith, Peter C; Schmidt, Susan M; Allensworth-Davies, Donald; Saitz, Richard
2010-07-12
Drug use (illicit drug use and nonmedical use of prescription drugs) is common but underrecognized in primary care settings. We validated a single-question screening test for drug use and drug use disorders in primary care. Adult patients recruited from primary care waiting rooms were asked the single screening question, "How many times in the past year have you used an illegal drug or used a prescription medication for nonmedical reasons?" A response of at least 1 time was considered positive for drug use. They were also asked the 10-item Drug Abuse Screening Test (DAST-10). The reference standard was the presence or absence of current (past year) drug use or a drug use disorder (abuse or dependence) as determined by a standardized diagnostic interview. Drug use was also determined by oral fluid testing for common drugs of abuse. Of 394 eligible primary care patients, 286 (73%) completed the interview. The single screening question was 100% sensitive (95% confidence interval [CI], 90.6%-100%) and 73.5% specific (95% CI, 67.7%-78.6%) for the detection of a drug use disorder. It was less sensitive for the detection of self-reported current drug use (92.9%; 95% CI, 86.1%-96.5%) and drug use detected by oral fluid testing or self-report (81.8%; 95% CI, 72.5%-88.5%). Test characteristics were similar to those of the DAST-10 and were affected very little by participant demographic characteristics. The single screening question accurately identified drug use in this sample of primary care patients, supporting the usefulness of this brief screen in primary care.
Static tensile and tensile creep testing of five ceramic fibers at elevated temperatures
NASA Technical Reports Server (NTRS)
Zimmerman, Richard S.; Adams, Donald F.
1989-01-01
Static tensile and tensile creep testing of five ceramic fibers at elevated temperature was performed. J.P. Stevens, Co., Astroquartz 9288 glass fiber; Nippon Carbon, Ltd., (Dow Corning) nicalon NLM-102 silicon carbide fiber; and 3M Company Nextel 312, 380, and 480 alumina/silica/boria fibers were supplied in unsized tows. Single fibers were separated from the tows and tested in static tension and tensile creep. Elevated test temperatures ranged from 400 C to 1300 C and varied for each fiber. Room temperature static tension was also performed. Computer software was written to reduce all single fiber test data into engineering constants using ASTM Standard Test Method D3379-75 as a reference. A high temperature furnace was designed and built to perform the single fiber elevated temperature testing up to 1300 C. A computerized single fiber creep apparatus was designed and constructed to perform four fiber creep tests simultaneously at temperatures up to 1300 C. Computer software was written to acquire and reduce all creep data.
Static tensile and tensile creep testing of five ceramic fibers at elevated temperatures
NASA Technical Reports Server (NTRS)
Zimmerman, Richard S.; Adams, Donald F.
1988-01-01
Static tensile and tensile creep testing of five ceramic fibers at elevated temperature was performed. J.P. Stevens, Co., Astroquartz 9288 glass fiber, Nippon Carbon, Ltd., (Dow Corning) Nicalon NLM-102 silicon carbide fiber, and 3M Company Nextel 312, 380, and 480 alumina/silica/boria fibers were supplied in unsized tows. Single fibers were separated from the tows and tested in static tension and tensile creep. Elevated test temperatures ranged from 400 to 1300 C and varied for each fiber. Room temperature static tension was also performed. Computer software was written to reduce all single fiber test data into engineering constants using ASTM Standard Test Method D3379-75 as a reference. A high temperature furnace was designed and built to perform the single fiber elevated temperature testing up to 1300 C. A computerized single fiber creep apparatus was designed and constructed to perform four fiber creep tests simultaneously at temperatures up to 1300 C. Computer software was written to acquire and reduce all creep data.
ERIC Educational Resources Information Center
Mulkey, Lynn M.; Morton, Peter J.
This investigation revives direct impact explanations of single-parent effects on student performance by further disagreggation by sex of the student. The effect of living in a single-parent household on the standardized test scores of students was estimated separately for males and females through analyses of data from the High School and Beyond…
Single-Item Measurement of Suicidal Behaviors: Validity and Consequences of Misclassification
Millner, Alexander J.; Lee, Michael D.; Nock, Matthew K.
2015-01-01
Suicide is a leading cause of death worldwide. Although research has made strides in better defining suicidal behaviors, there has been less focus on accurate measurement. Currently, the widespread use of self-report, single-item questions to assess suicide ideation, plans and attempts may contribute to measurement problems and misclassification. We examined the validity of single-item measurement and the potential for statistical errors. Over 1,500 participants completed an online survey containing single-item questions regarding a history of suicidal behaviors, followed by questions with more precise language, multiple response options and narrative responses to examine the validity of single-item questions. We also conducted simulations to test whether common statistical tests are robust against the degree of misclassification produced by the use of single-items. We found that 11.3% of participants that endorsed a single-item suicide attempt measure engaged in behavior that would not meet the standard definition of a suicide attempt. Similarly, 8.8% of those who endorsed a single-item measure of suicide ideation endorsed thoughts that would not meet standard definitions of suicide ideation. Statistical simulations revealed that this level of misclassification substantially decreases statistical power and increases the likelihood of false conclusions from statistical tests. Providing a wider range of response options for each item reduced the misclassification rate by approximately half. Overall, the use of single-item, self-report questions to assess the presence of suicidal behaviors leads to misclassification, increasing the likelihood of statistical decision errors. Improving the measurement of suicidal behaviors is critical to increase understanding and prevention of suicide. PMID:26496707
Qualitative Examination of Children's Naming Skills through Test Adaptations.
ERIC Educational Resources Information Center
Fried-Oken, Melanie
1987-01-01
The Double Administration Naming Technique assists clinicians in obtaining qualitative information about a client's visual confrontation naming skills through administration of a standard naming test; readministration of the same test; identification of single and double errors; cuing for double naming errors; and qualitative analysis of naming…
Sawle, Leanne; Freeman, Jennifer; Marsden, Jonathan
2017-04-01
Balance is a complex construct, affected by multiple components such as strength and co-ordination. However, whilst assessing an athlete's dynamic balance is an important part of clinical examination, there is no gold standard measure. The multiple single-leg hop-stabilization test is a functional test which may offer a method of evaluating the dynamic attributes of balance, but it needs to show adequate intra-tester reliability. The purpose of this study was to assess the intra-rater reliability of a dynamic balance test, the multiple single-leg hop-stabilization test on the dominant and non-dominant legs. Intra-rater reliability study. Fifteen active participants were tested twice with a 10-minute break between tests. The outcome measure was the multiple single-leg hop-stabilization test score, based on a clinically assessed numerical scoring system. Results were analysed using an Intraclass Correlations Coefficient (ICC 2,1 ) and Bland-Altman plots. Regression analyses explored relationships between test scores, leg dominance, age and training (an alpha level of p = 0.05 was selected). ICCs for intra-rater reliability were 0.85 for the dominant and non-dominant legs (confidence intervals = 0.62-0.95 and 0.61-0.95 respectively). Bland-Altman plots showed scores within two standard deviations. A significant correlation was observed between the dominant and non-dominant leg on balance scores (R 2 =0.49, p<0.05), and better balance was associated with younger participants in their non-dominant leg (R 2 =0.28, p<0.05) and their dominant leg (R 2 =0.39, p<0.05), and a higher number of hours spent training for the non-dominant leg R 2 =0.37, p<0.05). The multiple single-leg hop-stabilisation test demonstrated strong intra-tester reliability with active participants. Younger participants who trained more, have better balance scores. This test may be a useful measure for evaluating the dynamic attributes of balance. 3.
Aero-thermal Calibration of the NASA Glenn Icing Research Tunnel (2000 Tests)
NASA Technical Reports Server (NTRS)
Gonsalez, Jose C.; Arrington, E. Allen; Curry, Monroe R., III
2001-01-01
Aerothermal calibration measurements and flow quality surveys were made in the test section of the Icing Research Tunnel at the NASA Glenn Research Center. These surveys were made following major facility modifications including widening of the heat exchanger tunnel section, replacement of the heat exchanger, installation of new turning vanes, and installation of new fan exit guide vanes. Standard practice at NASA Glenn requires that test section calibration and flow quality surveys be performed following such major facility modifications. A single horizontally oriented rake was used to survey the flow field at several vertical positions within a single cross-sectional plane of the test section. These surveys provided a detailed mapping of the total and static pressure, total temperature, Mach number, velocity, flow angle and turbulence intensity. Data were acquired over the entire velocity and total temperature range of the facility. No icing conditions were tested; however, the effects of air sprayed through the water injecting spray bars were assessed. All data indicate good flow quality. Mach number standard deviations were less than 0.0017, flow angle standard deviations were between 0.3 deg and 0.8 deg, total temperature standard deviations were between 0.5 and 1.8 F for subfreezing conditions, axial turbulence intensities varied between 0.3 and 1.0 percent, and transverse turbulence intensities varied between 0.3 and 1.5 percent. Measurement uncertainties were also quantified.
Out-of-School Time Program Test Score Impact for Black Children of Single-Parents
ERIC Educational Resources Information Center
Nagle, Barry T.
2013-01-01
Out-of-School Time programs and their impact on standardized college entrance exam scores for black or African-American children of single parents who have applied for a competitive college scholarship program is the study focus. Study importance is supported by the large percentage of black children raised by single parents, the large percentage…
Mobini, Sirous; Mackintosh, Bundy; Illingworth, Jo; Gega, Lina; Langdon, Peter; Hoppitt, Laura
2014-06-01
This study examines the effects of a single session of Cognitive Bias Modification to induce positive Interpretative bias (CBM-I) using standard or explicit instructions and an analogue of computer-administered CBT (c-CBT) program on modifying cognitive biases and social anxiety. A sample of 76 volunteers with social anxiety attended a research site. At both pre- and post-test, participants completed two computer-administered tests of interpretative and attentional biases and a self-report measure of social anxiety. Participants in the training conditions completed a single session of either standard or explicit CBM-I positive training and a c-CBT program. Participants in the Control (no training) condition completed a CBM-I neutral task matched the active CBM-I intervention in format and duration but did not encourage positive disambiguation of socially ambiguous or threatening scenarios. Participants in both CBM-I programs (either standard or explicit instructions) and the c-CBT condition exhibited more positive interpretations of ambiguous social scenarios at post-test and one-week follow-up as compared to the Control condition. Moreover, the results showed that CBM-I and c-CBT, to some extent, changed negative attention biases in a positive direction. Furthermore, the results showed that both CBM-I training conditions and c-CBT reduced social anxiety symptoms at one-week follow-up. This study used a single session of CBM-I training, however multi-sessions intervention might result in more endurable positive CBM-I changes. A computerised single session of CBM-I and an analogue of c-CBT program reduced negative interpretative biases and social anxiety. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.
Mobini, Sirous; Mackintosh, Bundy; Illingworth, Jo; Gega, Lina; Langdon, Peter; Hoppitt, Laura
2014-01-01
Background and objectives This study examines the effects of a single session of Cognitive Bias Modification to induce positive Interpretative bias (CBM-I) using standard or explicit instructions and an analogue of computer-administered CBT (c-CBT) program on modifying cognitive biases and social anxiety. Methods A sample of 76 volunteers with social anxiety attended a research site. At both pre- and post-test, participants completed two computer-administered tests of interpretative and attentional biases and a self-report measure of social anxiety. Participants in the training conditions completed a single session of either standard or explicit CBM-I positive training and a c-CBT program. Participants in the Control (no training) condition completed a CBM-I neutral task matched the active CBM-I intervention in format and duration but did not encourage positive disambiguation of socially ambiguous or threatening scenarios. Results Participants in both CBM-I programs (either standard or explicit instructions) and the c-CBT condition exhibited more positive interpretations of ambiguous social scenarios at post-test and one-week follow-up as compared to the Control condition. Moreover, the results showed that CBM-I and c-CBT, to some extent, changed negative attention biases in a positive direction. Furthermore, the results showed that both CBM-I training conditions and c-CBT reduced social anxiety symptoms at one-week follow-up. Limitations This study used a single session of CBM-I training, however multi-sessions intervention might result in more endurable positive CBM-I changes. Conclusions A computerised single session of CBM-I and an analogue of c-CBT program reduced negative interpretative biases and social anxiety. PMID:24412966
Prechamber equipped laser ignition for improved performance in natural gas engines
Almansour, Bader; Vasu, Subith; Gupta, Sreenath B.; ...
2017-04-25
Lean-burn operation of stationary natural gas engines offers lower NO x emissions and improved efficiency. A proven pathway to extend lean-burn operation has been to use laser ignition instead of standard spark ignition. However, under lean conditions, flame speed reduces thereby offsetting any efficiency gains resulting from the higher ratio of specific heats, γ. The reduced flame speeds, in turn, can be compensated with the use of a prechamber to result in volumetric ignition, and thereby lead to faster combustion. In this study, the optimal geometry of PCLI was identified through several tests in a single-cylinder engine as a compromisemore » between autoignition, NO x and soot formation within the prechamber. Subsequently, tests were conducted in a single-cylinder natural gas engine comparing the performance of three ignition systems: standard electrical spark ignition (SI), single-point laser ignition (LI), and prechamber equipped laser ignition (PCLI). Out of the three, the performance of PCLI was far superior compared to the other two. Efficiency gain of 2.1% points could be achieved while complying with EPA regulation (BSNO x < 1.34 kW-hr) and the industry standard for ignition stability (COV_IMEP < 5%). Finally, test results and data analysis are presented identifying the combustion mechanisms leading to the improved performance.« less
NASA Technical Reports Server (NTRS)
Reddell, Brandon; Bailey, Chuck; Nguyen, Kyson; O'Neill, Patrick; Gaza, Razvan; Patel, Chirag; Cooper, Jaime; Kalb, Theodore
2017-01-01
We present the results of SEE testing with high energy protons and with low and high energy heavy ions. This paper summarizes test results for components considered for Low Earth Orbit and Deep Space applications.
Tactile Aid Usage with Young Hearing-Impaired Children.
ERIC Educational Resources Information Center
Proctor, Adele
Five hearing impaired children (2 to 4 years old) were followed longitudinally while using a single channel, vibrotactile aid as a supplement to hearing aids. Standardized language tests (including the Scales of Early Communication Skills for Hearing Impaired Children, the Test for Auditory Comprehension of Language, and the Test for Auditory…
NASA Astrophysics Data System (ADS)
Huether, Jonas; Rupp, Peter; Kohlschreiber, Ina; André Weidenmann, Kay
2018-04-01
To obtain mechanical tensile properties of materials it is customary to equip the specimen directly with a device to measure strain and Young’s modulus correctly and only within the measuring length defined by the standards. Whereas a variety of tools such as extensometers, strain gauges and optical systems are available for specimens on coupon level, no market-ready tools to measure strains of single fibres during single fibre tensile tests are available. Although there is a standard for single fibre testing, the procedures described there are only capable of measuring strains of the whole testing setup rather than the strain of the fibre. Without a direct strain measurement on the specimen, the compliance of the test rig itself influences the determination of the Young’s modulus. This work aims to fill this gap by establishing an enhanced method to measure strains directly on the tested fibre and thus provide accurate values for Young’s modulus. It is demonstrated that by applying and then optically tracking fluorescing polymeric beads on single glass fibres, Young’s modulus is determined directly and with high repeatability, without a need to measure at different measuring lengths or compensating for the system compliance. Employing this method to glass fibres, a Young’s modulus of approximately 82.5 GPa was determined, which is in the range of values obtained by applying a conventional procedure. This enhanced measuring technology achieves high accuracy and repeatability while reducing scatter of the data. It was demonstrated that the fluorescing beads do not affect the fibre properties.
A Test Fixture for Simulating Human Limb Physiology and Soft Tissue Biomechanics
1989-04-14
Food and Drug Administration (FDA) has not promu!gated performance standards for vital signs monitors that determine blood pressure and heart rate...static char answer[] = "" double f~ttnun~pts, single, doubleit, triple; int single_ -leftover, doubleit I eftover , triple-Leftover; double sin
49 CFR 234.231 - Fouling wires.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 4 2011-10-01 2011-10-01 false Fouling wires. 234.231 Section 234.231..., Inspection, and Testing Maintenance Standards § 234.231 Fouling wires. Each set of fouling wires in a highway... single duplex wire with single plug acting as fouling wires is prohibited. Existing installations having...
49 CFR 234.231 - Fouling wires.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 4 2010-10-01 2010-10-01 false Fouling wires. 234.231 Section 234.231..., Inspection, and Testing Maintenance Standards § 234.231 Fouling wires. Each set of fouling wires in a highway... single duplex wire with single plug acting as fouling wires is prohibited. Existing installations having...
49 CFR 571.111 - Standard No. 111; Rear visibility.
Code of Federal Regulations, 2014 CFR
2014-10-01
... mirror that reflect images, excluding the mirror rim or mounting brackets. Environmental test fixture... defined in S15. Rearview image means a visual image, detected by means of a single source, of the area... function of producing the rearview image as required under this standard. Small manufacturer means an...
Conditional Standard Errors of Measurement for Composite Scores Using IRT
ERIC Educational Resources Information Center
Kolen, Michael J.; Wang, Tianyou; Lee, Won-Chan
2012-01-01
Composite scores are often formed from test scores on educational achievement test batteries to provide a single index of achievement over two or more content areas or two or more item types on that test. Composite scores are subject to measurement error, and as with scores on individual tests, the amount of error variability typically depends on…
Spatial and Temporal Analysis of Bias HAST System Temperature
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pfeifer, Kent B.; Furrer, III, Clint T; Sandoval, Paul Anthony
2017-03-01
High-reliability components for high-consequence systems require detailed testing of operation after having undergone highly accelerated stress testing (HAST) under unusual conditions of high-temperature and humidity. This paper describes the design and operation of a system called "Wormwood" that is a highly multiplexed temperature measurement system that is designed to operate under HAST conditions to allow measurement of the temperature as a function of time and position in a HAST chamber. HAST chambers have single-point temperature measurements that can be traceable to NIST standards. The objective of these "Wormwood" measurements is to verify the uniformity and stability of the remaining volumemore » of the HAST chamber with respect to the single traceable standard.« less
COMPUTER INTERFACED TOXICITY TESTING SYSTEM FOR SIMULATING VARIABLE EFFLUENT LOADING
Water quality criteria and standards are based primarily on toxicity tests carried out with single chemicals whose concentration is as nearly constant as possible. In the 'real world', however, organisms are exposed to mixtures of chemicals which usually have markedly fluctuating...
Stark, Zornitza; Tan, Tiong Y; Chong, Belinda; Brett, Gemma R; Yap, Patrick; Walsh, Maie; Yeung, Alison; Peters, Heidi; Mordaunt, Dylan; Cowie, Shannon; Amor, David J; Savarirayan, Ravi; McGillivray, George; Downie, Lilian; Ekert, Paul G; Theda, Christiane; James, Paul A; Yaplito-Lee, Joy; Ryan, Monique M; Leventer, Richard J; Creed, Emma; Macciocca, Ivan; Bell, Katrina M; Oshlack, Alicia; Sadedin, Simon; Georgeson, Peter; Anderson, Charlotte; Thorne, Natalie; Melbourne Genomics Health Alliance; Gaff, Clara; White, Susan M
2016-11-01
To prospectively evaluate the diagnostic and clinical utility of singleton whole-exome sequencing (WES) as a first-tier test in infants with suspected monogenic disease. Singleton WES was performed as a first-tier sequencing test in infants recruited from a single pediatric tertiary center. This occurred in parallel with standard investigations, including single- or multigene panel sequencing when clinically indicated. The diagnosis rate, clinical utility, and impact on management of singleton WES were evaluated. Of 80 enrolled infants, 46 received a molecular genetic diagnosis through singleton WES (57.5%) compared with 11 (13.75%) who underwent standard investigations in the same patient group. Clinical management changed following exome diagnosis in 15 of 46 diagnosed participants (32.6%). Twelve relatives received a genetic diagnosis following cascade testing, and 28 couples were identified as being at high risk of recurrence in future pregnancies. This prospective study provides strong evidence for increased diagnostic and clinical utility of singleton WES as a first-tier sequencing test for infants with a suspected monogenic disorder. Singleton WES outperformed standard care in terms of diagnosis rate and the benefits of a diagnosis, namely, impact on management of the child and clarification of reproductive risks for the extended family in a timely manner.Genet Med 18 11, 1090-1096.
Heavy Ion Irradiation Fluence Dependence for Single-Event Upsets in a NAND Flash Memory
NASA Technical Reports Server (NTRS)
Chen, Dakai; Wilcox, Edward; Ladbury, Raymond L.; Kim, Hak; Phan, Anthony; Seidleck, Christina; Label, Kenneth
2016-01-01
We investigated the single-event effect (SEE) susceptibility of the Micron 16 nm NAND flash, and found that the single-event upset (SEU) cross section varied inversely with cumulative fluence. We attribute the effect to the variable upset sensitivities of the memory cells. Furthermore, the effect impacts only single cell upsets in general. The rate of multiple-bit upsets remained relatively constant with fluence. The current test standards and procedures assume that SEU follow a Poisson process and do not take into account the variability in the error rate with fluence. Therefore, traditional SEE testing techniques may underestimate the on-orbit event rate for a device with variable upset sensitivity.
49 CFR 571.135 - Standard No. 135; Light vehicle brake systems.
Code of Federal Regulations, 2012 CFR
2012-10-01
... portable sources of electrical current, and which may include a non-electrical source of power designed to... or more subsystems actuated by a single control, designed so that a single failure in any subsystem....2.1. Pavement friction. Unless otherwise specified, the road test surface produces a peak friction...
49 CFR 571.135 - Standard No. 135; Light vehicle brake systems.
Code of Federal Regulations, 2014 CFR
2014-10-01
... portable sources of electrical current, and which may include a non-electrical source of power designed to... or more subsystems actuated by a single control, designed so that a single failure in any subsystem....2.1. Pavement friction. Unless otherwise specified, the road test surface produces a peak friction...
49 CFR 571.135 - Standard No. 135; Light vehicle brake systems.
Code of Federal Regulations, 2013 CFR
2013-10-01
... portable sources of electrical current, and which may include a non-electrical source of power designed to... or more subsystems actuated by a single control, designed so that a single failure in any subsystem....2.1. Pavement friction. Unless otherwise specified, the road test surface produces a peak friction...
49 CFR 571.135 - Standard No. 135; Light vehicle brake systems.
Code of Federal Regulations, 2010 CFR
2010-10-01
... portable sources of electrical current, and which may include a non-electrical source of power designed to... or more subsystems actuated by a single control, designed so that a single failure in any subsystem....2.1. Pavement friction. Unless otherwise specified, the road test surface produces a peak friction...
49 CFR 571.135 - Standard No. 135; Light vehicle brake systems.
Code of Federal Regulations, 2011 CFR
2011-10-01
... portable sources of electrical current, and which may include a non-electrical source of power designed to... or more subsystems actuated by a single control, designed so that a single failure in any subsystem....2.1. Pavement friction. Unless otherwise specified, the road test surface produces a peak friction...
Castelein, Birgit; Cagnie, Barbara; Parlevliet, Thierry; Danneels, Lieven; Cools, Ann
2015-10-01
To identify maximum voluntary isometric contraction (MVIC) test positions for the deeper-lying scapulothoracic muscles (ie, levator scapulae, pectoralis minor, rhomboid major), and to provide a standard set of a limited number of test positions that generate an MVIC in all scapulothoracic muscles. Cross-sectional study. Physical and rehabilitation medicine department. Healthy subjects (N=21). Not applicable. Mean peak electromyographic activity from levator scapulae, pectoralis minor, and rhomboid major (investigated with fine-wire electromyography) and from upper trapezius, middle trapezius, lower trapezius, and serratus anterior (investigated with surface electromyography) during the performance of 12 different MVICs. The results indicated that various test positions generated similar high mean electromyographic activity and that no single test generated maximum activity for a specific muscle in all subjects. The results of this study support using a series of test positions for normalization procedures rather than a single exercise to increase the likelihood of recruiting the highest activity in the scapulothoracic muscles. A standard set of 5 test positions was identified as being sufficient for generating an MVIC of all scapulothoracic muscles: seated T, seated U 135°, prone T-thumbs up, prone V-thumbs up, and supine V-thumbs up. A standard set of test positions for normalization of scapulothoracic electromyographic data that also incorporates the levator scapulae, pectoralis minor, and rhomboid major muscles is 1 step toward a more comprehensive understanding of normal and abnormal muscle function of these muscles and will help to standardize the presentation of scapulothoracic electromyographic muscle activity. Copyright © 2015 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Naked-eye fingerprinting of single nucleotide polymorphisms on psoriasis patients
NASA Astrophysics Data System (ADS)
Valentini, Paola; Marsella, Alessandra; Tarantino, Paolo; Mauro, Salvatore; Baglietto, Silvia; Congedo, Maurizio; Paolo Pompa, Pier
2016-05-01
We report a low-cost test, based on gold nanoparticles, for the colorimetric (naked-eye) fingerprinting of a panel of single nucleotide polymorphisms (SNPs), relevant for the personalized therapy of psoriasis. Such pharmacogenomic tests are not routinely performed on psoriasis patients, due to the high cost of standard technologies. We demonstrated high sensitivity and specificity of our colorimetric test by validating it on a cohort of 30 patients, through a double-blind comparison with two state-of-the-art instrumental techniques, namely reverse dot blotting and sequencing, finding 100% agreement. This test offers high parallelization capabilities and can be easily generalized to other SNPs of clinical relevance, finding broad utility in diagnostics and pharmacogenomics.We report a low-cost test, based on gold nanoparticles, for the colorimetric (naked-eye) fingerprinting of a panel of single nucleotide polymorphisms (SNPs), relevant for the personalized therapy of psoriasis. Such pharmacogenomic tests are not routinely performed on psoriasis patients, due to the high cost of standard technologies. We demonstrated high sensitivity and specificity of our colorimetric test by validating it on a cohort of 30 patients, through a double-blind comparison with two state-of-the-art instrumental techniques, namely reverse dot blotting and sequencing, finding 100% agreement. This test offers high parallelization capabilities and can be easily generalized to other SNPs of clinical relevance, finding broad utility in diagnostics and pharmacogenomics. Electronic supplementary information (ESI) available. See DOI: 10.1039/c6nr02200f
Norman, J Farley; Cheeseman, Jacob R; Baxter, Michael W; Thomason, Kelsey E; Adkins, Olivia C; Rogers, Connor E
2014-05-01
Younger (20-25 years of age) and older (61-79 years) adults were evaluated for their ability to visually discriminate length. Almost all experiments that have utilized the method of single stimuli to date have required participants to judge test stimuli relative to a single implicit standard (for a rare exception, see Morgan, On the scaling of size judgements by orientational cues, Vision Research, 1992, 32, 1433-1445). In the current experiments, we not only asked participants to judge lengths relative to a single implicit standard, but they also compared test stimuli to two different implicit standards within the same blocks of trials. We analyzed our participants' judgments to evaluate whether significant sequential dependencies occurred. We found that while individual younger and older adults possessed similar length difference thresholds and exhibited similar overall biases, the judgments of older adults within individual blocks of trials were more strongly biased (than younger adults) by preceding responses (i.e., their judgments on any given trial were more strongly affected by responses to previously viewed stimuli). In addition, the judgments of both younger and older adults were more strongly biased by preceding responses in the blocks of trials with multiple implicit standards. Overall, our results are consistent with the operation of the tracking mechanism described by Criterion-setting theory (Lages and Treisman, Spatial frequency discrimination: Visual long-term memory or criterion setting? Vision Research, 1998, 38, 557-572). Copyright © 2014 Elsevier Ltd. All rights reserved.
Yang, Yang; DeGruttola, Victor
2016-01-01
Traditional resampling-based tests for homogeneity in covariance matrices across multiple groups resample residuals, that is, data centered by group means. These residuals do not share the same second moments when the null hypothesis is false, which makes them difficult to use in the setting of multiple testing. An alternative approach is to resample standardized residuals, data centered by group sample means and standardized by group sample covariance matrices. This approach, however, has been observed to inflate type I error when sample size is small or data are generated from heavy-tailed distributions. We propose to improve this approach by using robust estimation for the first and second moments. We discuss two statistics: the Bartlett statistic and a statistic based on eigen-decomposition of sample covariance matrices. Both statistics can be expressed in terms of standardized errors under the null hypothesis. These methods are extended to test homogeneity in correlation matrices. Using simulation studies, we demonstrate that the robust resampling approach provides comparable or superior performance, relative to traditional approaches, for single testing and reasonable performance for multiple testing. The proposed methods are applied to data collected in an HIV vaccine trial to investigate possible determinants, including vaccine status, vaccine-induced immune response level and viral genotype, of unusual correlation pattern between HIV viral load and CD4 count in newly infected patients. PMID:22740584
Yang, Yang; DeGruttola, Victor
2012-06-22
Traditional resampling-based tests for homogeneity in covariance matrices across multiple groups resample residuals, that is, data centered by group means. These residuals do not share the same second moments when the null hypothesis is false, which makes them difficult to use in the setting of multiple testing. An alternative approach is to resample standardized residuals, data centered by group sample means and standardized by group sample covariance matrices. This approach, however, has been observed to inflate type I error when sample size is small or data are generated from heavy-tailed distributions. We propose to improve this approach by using robust estimation for the first and second moments. We discuss two statistics: the Bartlett statistic and a statistic based on eigen-decomposition of sample covariance matrices. Both statistics can be expressed in terms of standardized errors under the null hypothesis. These methods are extended to test homogeneity in correlation matrices. Using simulation studies, we demonstrate that the robust resampling approach provides comparable or superior performance, relative to traditional approaches, for single testing and reasonable performance for multiple testing. The proposed methods are applied to data collected in an HIV vaccine trial to investigate possible determinants, including vaccine status, vaccine-induced immune response level and viral genotype, of unusual correlation pattern between HIV viral load and CD4 count in newly infected patients.
Deans, Zandra C; Costa, Jose Luis; Cree, Ian; Dequeker, Els; Edsjö, Anders; Henderson, Shirley; Hummel, Michael; Ligtenberg, Marjolijn Jl; Loddo, Marco; Machado, Jose Carlos; Marchetti, Antonio; Marquis, Katherine; Mason, Joanne; Normanno, Nicola; Rouleau, Etienne; Schuuring, Ed; Snelson, Keeda-Marie; Thunnissen, Erik; Tops, Bastiaan; Williams, Gareth; van Krieken, Han; Hall, Jacqueline A
2017-01-01
The clinical demand for mutation detection within multiple genes from a single tumour sample requires molecular diagnostic laboratories to develop rapid, high-throughput, highly sensitive, accurate and parallel testing within tight budget constraints. To meet this demand, many laboratories employ next-generation sequencing (NGS) based on small amplicons. Building on existing publications and general guidance for the clinical use of NGS and learnings from germline testing, the following guidelines establish consensus standards for somatic diagnostic testing, specifically for identifying and reporting mutations in solid tumours. These guidelines cover the testing strategy, implementation of testing within clinical service, sample requirements, data analysis and reporting of results. In conjunction with appropriate staff training and international standards for laboratory testing, these consensus standards for the use of NGS in molecular pathology of solid tumours will assist laboratories in implementing NGS in clinical services.
Gray, Dean; LeVanseler, Kerri; Pan, Meide
2008-01-01
A single laboratory validation (SLV) was completed for a method to determine the flavonol aglycones quercetin, kaempferol, and isorhamnetin in Ginkgo biloba products. The method calculates total glycosides based on these aglycones formed following acid hydrolysis. Nine matrixes were chosen for the study, including crude leaf material, standardized dry powder extract, single and multiple entity finished products, and ethanol and glycerol tinctures. For the 9 matrixes evaluated as part of this SLV, the method appeared to be selective and specific, with no observed interferences. The simplified 60 min oven heating hydrolysis procedure was effective for each of the matrixes studied, with no apparent or consistent differences between 60, 75, and 90 min at 90°C. A Youden ruggedness trial testing 7 factors with the potential to affect quantitative results showed that 2 factors (volume hydrolyzed and test sample extraction/hydrolysis weight) were the most important parameters for control during sample preparation. The method performed well in terms of precision, with 4 matrixes tested in triplicate over a 3-day period showing an overall repeatability (relative standard deviation, RSD) of 2.3%. Analysis of variance testing at α = 0.05 showed no significant differences among the within- or between-group sources of variation, although comparisons of within-day (Sw), between-day (Sb), and total (St) precision showed that a majority of the standard deviation came from within-day determinations for all matrixes. Accuracy testing at 2 levels (approximately 30 and 90% of the determined concentrations in standardized dry powder extract) from 2 complex negative control matrixes showed an overall 96% recovery and RSD of 1.0% for the high spike, and 94% recovery and RSD of 2.5% for the low spike. HorRat scores were within the limits for performance acceptability, ranging from 0.4 to 1.3. Based on the performance results presented herein, it is recommended that this method progress to the collaborative laboratory trial. PMID:16001841
Ren, Li; Tao, Weiwei; Zhang, Hailou; Xue, Wenda; Tang, Juanjuan; Wu, Ruyan; Xia, Baomei; Wu, Haoxing; Chen, Gang
2016-07-01
Gardenia jasminoides Ellis (GJ) is one of the five constituents of Yueju pill, a Traditional Chinese Medicine for treatment of syndromes associated with mood disorders. Recently, preclinical and clinical studies suggest that Yueju pill confers rapid antidepressant effects. GJ is identified as the constituent primary for Yueju pill's rapid antidepressant effects. GJ's antidepressant action is temporally associated with up-regulated expression of brain-derived neurotrophic factor (BDNF) in the hippocampus. The present study aimed to identify chemical fractions responsible for the rapid antidepressant efficacy of GJ and its association with BDNF signaling. Four fractions of GJ were extracted using standardized procedure. The four fractions were screened for rapid antidepressant potential, using the behavioral paradigm of forced swimming test (FST) and tail suspension test (TST) assessed at 24h post a single administration. A single dose of the putatively effective fractions was further tested in mice exposed to chronic mild stress (CMS), followed with a comprehensive behavioral testing including TST, FST, sucrose preference test (SPT), and novelty suppressed-feeding (NSF). To test the association of BDNF signaling with rapid antidepressant effects of effective factions, the expressions of BDNF and its receptor tropomyosin receptor kinase B (TrkB) in the hippocampus were assessed at different times post a single administration of effective fractions. Both petroleum ether (GJ-PE) and n-butyl alcohol fraction (GJ-BO) fractions of GJ displayed rapid antidepressant potential in the FST. In the TST, the antidepressant effects of GJ-PE lasted for a longer time than GJ-BO. Acute administration of either GJ-PE or GJ-BO significantly reversed the behavioral deficits in the tests of TST, FST, SPT and NSF in chronically stressed mice, confirming both fractions conferred rapid antidepressant efficacy. Interestingly, GJ-PE, but not GJ-BO, increased the expression of BDNF and TrkB in the hippocampus post a single administration. Two standardized fractions GJ-PE and GJ-BO exhibited comparable rapid antidepressant-like effects on the CMS mice. However, only the effects of GJ-PE was associated with BDNF signaling. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
The standard of medical care under the Australian Civil Liability Acts: ten years on.
Lee, Joseph
2014-12-01
It has been more than a decade since the modified Bolam test was legislatively enacted.by the Australian States following the medical indemnity crisis. Since its implementation, the modified Bolam test has been configured by judges as a defence to the common law standard of care in medical diagnosis and treatment. The article argues against this interpretation and suggests an alternative way of implementing this statutory test. It is proposed that the modified Bolam test ought to have been applied as a single yardstick to determine the required standard of care in diagnosis and treatment. Changes are also recommended to reform the test with a view to striking a balance between the interests of patients and doctors in medical disputes, and strengthening judicial supervision of the medical profession. These proposed reforms could resolve the shortcomings of the common law more effectively. They may also enhance the standard of medical care in Australia in the long run.
USDA-ARS?s Scientific Manuscript database
The five day sodium carbonate-ammonium nitrate extraction assay has been proposed by the AAFPCO as a standard test to identify fertilizers that provide plant-available Si. A single-lab validation test was previously performed; however, the analysis lacked any correlation to a grow-out study. To do...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-20
... Efficiency at all Possible Voltages b. Posting the Highest and Lowest Efficiencies c. Test at Single Manufacturer-Declared Voltage d. Test at Highest-Rated Voltage e. Test on Input Voltage Based on Wattage and... at the highest voltage for which the ballast is designed to operate. [Dagger] P is defined as the...
Evaluation of digital real-time PCR assay as a molecular diagnostic tool for single-cell analysis.
Chang, Chia-Hao; Mau-Hsu, Daxen; Chen, Ke-Cheng; Wei, Cheng-Wey; Chiu, Chiung-Ying; Young, Tai-Horng
2018-02-21
In a single-cell study, isolating and identifying single cells are essential, but these processes often require a large investment of time or money. The aim of this study was to isolate and analyse single cells using a novel platform, the PanelChip™ Analysis System, which includes 2500 microwells chip and a digital real-time polymerase chain reaction (dqPCR) assay, in comparison with a standard PCR (qPCR) assay. Through the serial dilution of a known concentration standard, namely pUC19, the accuracy and sensitivity levels of two methodologies were compared. The two systems were tested on the basis of expression levels of the genetic markers vimentin, E-cadherin, N-cadherin and GAPDH in A549 lung carcinoma cells at two known concentrations. Furthermore, the influence of a known PCR inhibitor commonly found in blood samples, heparin, was evaluated in both methodologies. Finally, mathematical models were proposed and separation method of single cells was verified; moreover, gene expression levels during epithelial-mesenchymal transition in single cells under TGFβ1 treatment were measured. The drawn conclusion is that dqPCR performed using PanelChip™ is superior to the standard qPCR in terms of sensitivity, precision, and heparin tolerance. The dqPCR assay is a potential tool for clinical diagnosis and single-cell applications.
Cortesi, Marilisa; Bandiera, Lucia; Pasini, Alice; Bevilacqua, Alessandro; Gherardi, Alessandro; Furini, Simone; Giordano, Emanuele
2017-01-01
Quantifying gene expression at single cell level is fundamental for the complete characterization of synthetic gene circuits, due to the significant impact of noise and inter-cellular variability on the system's functionality. Commercial set-ups that allow the acquisition of fluorescent signal at single cell level (flow cytometers or quantitative microscopes) are expensive apparatuses that are hardly affordable by small laboratories. A protocol that makes a standard optical microscope able to acquire quantitative, single cell, fluorescent data from a bacterial population transformed with synthetic gene circuitry is presented. Single cell fluorescence values, acquired with a microscope set-up and processed with custom-made software, are compared with results that were obtained with a flow cytometer in a bacterial population transformed with the same gene circuitry. The high correlation between data from the two experimental set-ups, with a correlation coefficient computed over the tested dynamic range > 0.99, proves that a standard optical microscope- when coupled with appropriate software for image processing- might be used for quantitative single-cell fluorescence measurements. The calibration of the set-up, together with its validation, is described. The experimental protocol described in this paper makes quantitative measurement of single cell fluorescence accessible to laboratories equipped with standard optical microscope set-ups. Our method allows for an affordable measurement/quantification of intercellular variability, whose better understanding of this phenomenon will improve our comprehension of cellular behaviors and the design of synthetic gene circuits. All the required software is freely available to the synthetic biology community (MUSIQ Microscope flUorescence SIngle cell Quantification).
Kanthaswamy, S
2015-10-01
This review highlights the importance of domestic animal genetic evidence sources, genetic testing, markers and analytical approaches as well as the challenges this field is facing in view of the de facto 'gold standard' human DNA identification. Because of the genetic similarity between humans and domestic animals, genetic analysis of domestic animal hair, saliva, urine, blood and other biological material has generated vital investigative leads that have been admitted into a variety of court proceedings, including criminal and civil litigation. Information on validated short tandem repeat, single nucleotide polymorphism and mitochondrial DNA markers and public access to genetic databases for forensic DNA analysis is becoming readily available. Although the fundamental aspects of animal forensic genetic testing may be reliable and acceptable, animal forensic testing still lacks the standardized testing protocols that human genetic profiling requires, probably because of the absence of monetary support from government agencies and the difficulty in promoting cooperation among competing laboratories. Moreover, there is a lack in consensus about how to best present the results and expert opinion to comply with court standards and bear judicial scrutiny. This has been the single most persistent challenge ever since the earliest use of domestic animal forensic genetic testing in a criminal case in the mid-1990s. Crime laboratory accreditation ensures that genetic test results have the courts' confidence. Because accreditation requires significant commitments of effort, time and resources, the vast majority of animal forensic genetic laboratories are not accredited nor are their analysts certified forensic examiners. The relevance of domestic animal forensic genetics in the criminal justice system is undeniable. However, further improvements are needed in a wide range of supporting resources, including standardized quality assurance and control protocols for sample handling, evidence testing, statistical analysis and reporting that meet the rules of scientific acceptance, reliability and human forensic identification standards. © 2015 Stichting International Foundation for Animal Genetics.
The development of STS payload environmental engineering standards
NASA Technical Reports Server (NTRS)
Bangs, W. F.
1982-01-01
The presently reported effort to provide a single set of standards for the design, analysis and testing of Space Transportation System (STS) payloads throughout the NASA organization must be viewed as essentially experimental, since the concept of incorporating the diverse opinions and experiences of several separate field research centers may in retrospect be judged too ambitious or perhaps even naive. While each STS payload may have unique characteristics, and the project should formulate its own criteria for environmental design, testing and evaluation, a reference source document providing coordinated standards is expected to minimize the duplication of effort and limit random divergence of practices among the various NASA payload programs. These standards would provide useful information to all potential STS users, and offer a degree of standardization to STS users outside the NASA organization.
29 CFR 1926.703 - Requirements for cast-in-place concrete.
Code of Federal Regulations, 2013 CFR
2013-07-01
... members have been designed for such loading. (8) Whenever single post shores are used one on top of... been properly tested with an appropriate ASTM standard test method designed to indicate the concrete...) Formwork shall be designed, fabricated, erected, supported, braced and maintained so that it will be...
29 CFR 1926.703 - Requirements for cast-in-place concrete.
Code of Federal Regulations, 2011 CFR
2011-07-01
... members have been designed for such loading. (8) Whenever single post shores are used one on top of... been properly tested with an appropriate ASTM standard test method designed to indicate the concrete...) Formwork shall be designed, fabricated, erected, supported, braced and maintained so that it will be...
29 CFR 1926.703 - Requirements for cast-in-place concrete.
Code of Federal Regulations, 2014 CFR
2014-07-01
... members have been designed for such loading. (8) Whenever single post shores are used one on top of... been properly tested with an appropriate ASTM standard test method designed to indicate the concrete...) Formwork shall be designed, fabricated, erected, supported, braced and maintained so that it will be...
29 CFR 1926.703 - Requirements for cast-in-place concrete.
Code of Federal Regulations, 2012 CFR
2012-07-01
... members have been designed for such loading. (8) Whenever single post shores are used one on top of... been properly tested with an appropriate ASTM standard test method designed to indicate the concrete...) Formwork shall be designed, fabricated, erected, supported, braced and maintained so that it will be...
29 CFR 1926.703 - Requirements for cast-in-place concrete.
Code of Federal Regulations, 2010 CFR
2010-07-01
... members have been designed for such loading. (8) Whenever single post shores are used one on top of... been properly tested with an appropriate ASTM standard test method designed to indicate the concrete...) Formwork shall be designed, fabricated, erected, supported, braced and maintained so that it will be...
A single sample GnRHa stimulation test in the diagnosis of precocious puberty
USDA-ARS?s Scientific Manuscript database
Gonadotropin-releasing hormone (GnRH) has been the standard test for diagnosing central precocious puberty. Because GnRH is no longer available, GnRH analogues (GnRHa) are now used. Random LH concentration, measured by the third-generation immunochemiluminometric assay, is a useful screening tool ...
2016-08-01
platforms. 15. SUBJECT TERMS Antibody Antibody Technology Program (ATP) Quality Enzyme-linked immunosorbent assay ( ELISA ) Biosurveillance Single-chain...2.6 Thermal Stress Test............................................................................................4 2.7 ELISA ...3.5 ELISA Results .................................................................................................11 3.6 SPR Results
Southern pine veneer laminates at various moduli of elasticity
George E. Woodson
1972-01-01
Modulus of rigidity (GLT) of veneer laminates was shown to be unrelated to dynamic modulus of elasticity (Ed) of single veneers and also, within the range of samples tested, unrelated to specific gravity. Values determined by flexure test (GLR) were consistent with those from standard plate shear...
14 CFR 35.15 - Safety analysis.
Code of Federal Regulations, 2014 CFR
2014-01-01
... combined with sound design and test philosophies. (b) If significant doubt exists as to the effects of... STANDARDS: PROPELLERS Design and Construction § 35.15 Safety analysis. (a)(1) The applicant must analyze the... to be verified by test. (c) The primary failures of certain single propeller elements (for example...
14 CFR 35.15 - Safety analysis.
Code of Federal Regulations, 2013 CFR
2013-01-01
... combined with sound design and test philosophies. (b) If significant doubt exists as to the effects of... STANDARDS: PROPELLERS Design and Construction § 35.15 Safety analysis. (a)(1) The applicant must analyze the... to be verified by test. (c) The primary failures of certain single elements (for example, blades...
14 CFR 35.15 - Safety analysis.
Code of Federal Regulations, 2012 CFR
2012-01-01
... combined with sound design and test philosophies. (b) If significant doubt exists as to the effects of... STANDARDS: PROPELLERS Design and Construction § 35.15 Safety analysis. (a)(1) The applicant must analyze the... to be verified by test. (c) The primary failures of certain single elements (for example, blades...
14 CFR 35.15 - Safety analysis.
Code of Federal Regulations, 2010 CFR
2010-01-01
... combined with sound design and test philosophies. (b) If significant doubt exists as to the effects of... STANDARDS: PROPELLERS Design and Construction § 35.15 Safety analysis. (a)(1) The applicant must analyze the... to be verified by test. (c) The primary failures of certain single elements (for example, blades...
Preliminary development of an ultrabrief two-item bedside test for delirium.
Fick, Donna M; Inouye, Sharon K; Guess, Jamey; Ngo, Long H; Jones, Richard N; Saczynski, Jane S; Marcantonio, Edward R
2015-10-01
Delirium is common, morbid, and costly, yet is greatly under-recognized among hospitalized older adults. To identify the best single and pair of mental status test items that predict the presence of delirium. Diagnostic test evaluation study that enrolled medicine inpatients aged 75 years or older at an academic medical center. Patients underwent a clinical reference standard assessment involving a patient interview, medical record review, and interviews with family members and nurses to determine the presence or absence of Diagnostic and Statistical Manual of Mental Disorders, 4th Edition defined delirium. Participants also underwent the three-dimensional Confusion Assessment Method (3D-CAM), a brief, validated assessment for delirium. Individual items and pairs of items from the 3D-CAM were evaluated to determine sensitivity and specificity relative to the reference standard delirium diagnosis. Of the 201 participants (mean age 84 years, 62% female), 42 (21%) had delirium based on the clinical reference standard. The single item with the best test characteristics was "months of the year backwards" with a sensitivity of 83% (95% confidence interval [CI]: 69%-93%) and specificity of 69% (95% CI: 61%-76%). The best 2-item screen was the combination of "months of the year backwards" and "what is the day of the week?" with a sensitivity of 93% (95% CI: 81%-99%) and specificity of 64% (95% CI: 56%-70%). We identified a single item with >80% and pair of items with >90% sensitivity for delirium. If validated prospectively, these items will serve as an initial innovative screening step for delirium identification in hospitalized older adults. © 2015 Society of Hospital Medicine.
NASA Technical Reports Server (NTRS)
Culpepper, William X.; ONeill, Pat; Nicholson, Leonard L.
2000-01-01
An internuclear cascade and evaporation model has been adapted to estimate the LET spectrum generated during testing with 200 MeV protons. The model-generated heavy ion LET spectrum is compared to the heavy ion LET spectrum seen on orbit. This comparison is the basis for predicting single event failure rates from heavy ions using results from a single proton test. Of equal importance, this spectra comparison also establishes an estimate of the risk of encountering a failure mode on orbit that was not detected during proton testing. Verification of the general results of the model is presented based on experiments, individual part test results, and flight data. Acceptance of this model and its estimate of remaining risk opens the hardware verification philosophy to the consideration of radiation testing with high energy protons at the board and box level instead of the more standard method of individual part testing with low energy heavy ions.
Pasquarelli, Noemi; Voehringer, Patrizia; Henke, Julia; Ferger, Boris
2017-08-30
The development of modern housing regimes such as individually ventilated cage (IVC) systems has become very popular and attractive in order to reduce spreading of pathogenic organisms and to lower the risk to develop a laboratory animal allergy for staff members. Additionally, optimal housing of laboratory animals contributes to improve animal health status and ensures high and comparable experimental and animal welfare standards. However, it has not been clearly elucidated whether 1) a change to IVC systems have an impact on various physiological phenotypic parameters of mice when compared to conventional, standard cages and 2) if this is further affected by changing from social to single housing. Therefore, we investigated the influence of a change in housing conditions (standard cages with social housing changed to standard or IVC cages combined with social or single housing) on body weight, behavior and a neurochemical fingerprint of male C57BL/6J mice. Body weight progression was significantly reduced when changing mice to single or social IVC cages as well as in single standard cages when compared to social standard housing. Automated motor activity measurement in the open field showed that mice maintained in social husbandry with standard cages displayed the lowest exploratory behavior but the highest activity difference upon amphetamine treatment. Elevated plus maze test revealed that a change to IVC single and social housing as well as single standard housing produced anxiety-related behavior when compared to maintenance in social standard housing. Additionally, postmortem neurochemical analysis of the striatum using high-performance liquid chromatography coupled to electrochemical detection showed significant differences in striatal dopamine and serotonin turnover levels. In summary, our data indicate a crucial influence of a change in housing conditions on several mouse phenotype parameters. We propose that the maintenance of well-defined housing conditions is mandatory to ensure reproducible and comparable results and contributes to the application of the 3R refinement principle in animal studies by contributing to welfare and hygienical standards. Copyright © 2017 Elsevier B.V. All rights reserved.
Yamamoto, Takeshi; Shimodaira, Kazuo; Yoshida, Seiji; Kurosawa, Yoji
2013-03-01
The Japan Aerospace Exploration Agency (JAXA) is conducting research and development on aircraft engine technologies to reduce environmental impact for the Technology Development Project for Clean Engines (TechCLEAN). As a part of the project, combustion technologies have been developed with an aggressive target that is an 80% reduction over the NO x threshold of the International Civil Aviation Organization (ICAO) Committee on Aviation Environmental Protection (CAEP)/4 standard. A staged fuel nozzle with a pilot mixer and a main mixer was developed and tested using a single-sector combustor under the target engine's landing and takeoff (LTO) cycle conditions with a rated output of 40 kN and an overall pressure ratio of 25.8. The test results showed a 77% reduction over the CAEP/4 NO x standard. However, the reduction in smoke at thrust conditions higher than the 30% MTO condition and of CO emission at thrust conditions lower than the 85% MTO condition are necessary. In the present study, an additional fuel burner was designed and tested with the staged fuel nozzle in a single-sector combustor to control emissions. The test results show that the combustor enables an 82% reduction in NO x emissions relative to the ICAO CAEP/4 standard and a drastic reduction in smoke and CO emissions.
Single-port access laparoscopic reversal of Hartmann operation.
Borowski, D W; Kanakala, V; Agarwal, A K; Tabaqchali, M A; Garg, D K; Gill, T S
2011-08-01
Single-port access offers cosmetic advantages in addition to the well-recognized benefits of standard multiport laparoscopic surgery, and can be performed with the use of standard straight instruments. We describe a technique of single-port access reversal of Hartmann colostomy by use of the colostomy site for access. After routine skin preparation and laparoscopic setup, the colostomy is mobilized from its mucocutaneous border, and the anvil of a circular stapler is secured to the distal lumen. By the use of a GelPoint system with 3 or 4 trocars, the intra-abdominal adhesions are divided and the splenic flexure is mobilized to achieve sufficient access to the abdominal and pelvic cavities and proximal colonic mobility. The rectal stump is mobilized to the mid rectum, starting from the posterior mesorectal fascia around to the anterior rectal wall. A tension-free colorectal anastomosis is secured with a standard circular stapling device inserted transanally, and leak tested. The colostomy wound is closed in standard fashion. Five patients underwent single-port access reversal of Hartmann resection (4 diverticular perforations and 1 pT3N0 colon cancer), with a mean operating time of 155 (range, 137-187) minutes and a median length of stay of 3 (range, 2-11) days. There were no conversions, major surgical morbidity, or deaths. Single-port access reversal of Hartmann colostomy through the stoma site is safe, and it offers additional cosmetic advantages with no apparent additional morbidity in comparison with standard multiport surgery.
Confidence intervals for single-case effect size measures based on randomization test inversion.
Michiels, Bart; Heyvaert, Mieke; Meulders, Ann; Onghena, Patrick
2017-02-01
In the current paper, we present a method to construct nonparametric confidence intervals (CIs) for single-case effect size measures in the context of various single-case designs. We use the relationship between a two-sided statistical hypothesis test at significance level α and a 100 (1 - α) % two-sided CI to construct CIs for any effect size measure θ that contain all point null hypothesis θ values that cannot be rejected by the hypothesis test at significance level α. This method of hypothesis test inversion (HTI) can be employed using a randomization test as the statistical hypothesis test in order to construct a nonparametric CI for θ. We will refer to this procedure as randomization test inversion (RTI). We illustrate RTI in a situation in which θ is the unstandardized and the standardized difference in means between two treatments in a completely randomized single-case design. Additionally, we demonstrate how RTI can be extended to other types of single-case designs. Finally, we discuss a few challenges for RTI as well as possibilities when using the method with other effect size measures, such as rank-based nonoverlap indices. Supplementary to this paper, we provide easy-to-use R code, which allows the user to construct nonparametric CIs according to the proposed method.
Secular changes in standards of bodily attractiveness in women: tests of a reproductive model.
Barber, N
1998-05-01
Since success at work is favored by a more slender body build while reproduction is favored by curvaceousness, standards of women's bodily attractiveness should be predictable from economic and reproductive variables. This hypothesis was tested in a replication and extension of a study by Silverstein, Perdue, Peterson, Vogel, and Fantini (1986) which looked at correlates of curvaceousness of Vogue models over time. As economic prosperity increased, and as women's participation in the economy, and higher education, increased, curvaceousness of the standards declined. As the proportion of single women to men, both aged 20-24 years, increased, and as the birth rate declined, curvaceousness was reduced. Results suggest that cultural standards of attractiveness are influenced by an evolved psychology of mate selection.
NASA Technical Reports Server (NTRS)
Johnson, S.
1976-01-01
This preliminary data report gives basic test results of a flat-plate solar collector whose performance was determined in the NASA-Lewis solar simulator. The collector was tested over ranges of inlet temperatures, fluxes and coolant flow rates. Collector efficienty is correlated in terms of inlet temperature and flux level.
Learning effect and test-retest variability of pulsar perimetry.
Salvetat, Maria Letizia; Zeppieri, Marco; Parisi, Lucia; Johnson, Chris A; Sampaolesi, Roberto; Brusini, Paolo
2013-03-01
To assess Pulsar Perimetry learning effect and test-retest variability (TRV) in normal (NORM), ocular hypertension (OHT), glaucomatous optic neuropathy (GON), and primary open-angle glaucoma (POAG) eyes. This multicenter prospective study included 43 NORM, 38 OHT, 33 GON, and 36 POAG patients. All patients underwent standard automated perimetry and Pulsar Contrast Perimetry using white stimuli modulated in phase and counterphase at 30 Hz (CP-T30W test). The learning effect and TRV for Pulsar Perimetry were assessed for 3 consecutive visual fields (VFs). The learning effect were evaluated by comparing results from the first session with the other 2. TRV was assessed by calculating the mean of the differences (in absolute value) between retests for each combination of single tests. TRV was calculated for Mean Sensitivity, Mean Defect, and single Mean Sensitivity for each 66 test locations. Influence of age, VF eccentricity, and loss severity on TRV were assessed using linear regression analysis and analysis of variance. The learning effect was not significant in any group (analysis of variance, P>0.05). TRV for Mean Sensitivity and Mean Defect was significantly lower in NORM and OHT (0.6 ± 0.5 spatial resolution contrast units) than in GON and POAG (0.9 ± 0.5 and 1.0 ± 0.8 spatial resolution contrast units, respectively) (Kruskal-Wallis test, P=0.04); however, the differences in NORM among age groups was not significant (Kruskal-Wallis test, P>0.05). Slight significant differences were found for the single Mean Sensitivity TRV among single locations (Duncan test, P<0.05). For POAG, TRV significantly increased with decreasing Mean Sensitivity and increasing Mean Defect (linear regression analysis, P<0.01). The Pulsar Perimetry CP-T30W test did not show significant learning effect in patients with standard automated perimetry experience. TRV for global indices was generally low, and was not related to patient age; it was only slightly affected by VF defect eccentricity, and significantly influenced by VF loss severity.
Assessing neglect dyslexia with compound words.
Reinhart, Stefan; Schunck, Alexander; Schaadt, Anna Katharina; Adams, Michaela; Simon, Alexandra; Kerkhoff, Georg
2016-10-01
The neglect syndrome is frequently associated with neglect dyslexia (ND), which is characterized by omissions or misread initial letters of single words. ND is usually assessed with standardized reading texts in clinical settings. However, particularly in the chronic phase of ND, patients often report reading deficits in everyday situations but show (nearly) normal performances in test situations that are commonly well-structured. To date, sensitive and standardized tests to assess the severity and characteristics of ND are lacking, although reading is of high relevance for daily life and vocational settings. Several studies found modulating effects of different word features on ND. We combined those features in a novel test to enhance test sensitivity in the assessment of ND. Low-frequency words of different length that contain residual pronounceable words when the initial letter strings are neglected were selected. We compared these words in a group of 12 ND-patients suffering from right-hemispheric first-ever stroke with word stimuli containing no existing residual words. Finally, we tested whether the serially presented words are more sensitive for the diagnosis of ND than text reading. The severity of ND was modulated strongly by the ND-test words and error frequencies in single word reading of ND words were on average more than 10 times higher than in a standardized text reading test (19.8% vs. 1.8%). The novel ND-test maximizes the frequency of specific ND-errors and is therefore more sensitive for the assessment of ND than conventional text reading tasks. (PsycINFO Database Record (c) 2016 APA, all rights reserved).
A standardized test battery for the study of synesthesia
Eagleman, David M.; Kagan, Arielle D.; Nelson, Stephanie S.; Sagaram, Deepak; Sarma, Anand K.
2014-01-01
Synesthesia is an unusual condition in which stimulation of one modality evokes sensation or experience in another modality. Although discussed in the literature well over a century ago, synesthesia slipped out of the scientific spotlight for decades because of the difficulty in verifying and quantifying private perceptual experiences. In recent years, the study of synesthesia has enjoyed a renaissance due to the introduction of tests that demonstrate the reality of the condition, its automatic and involuntary nature, and its measurable perceptual consequences. However, while several research groups now study synesthesia, there is no single protocol for comparing, contrasting and pooling synesthetic subjects across these groups. There is no standard battery of tests, no quantifiable scoring system, and no standard phrasing of questions. Additionally, the tests that exist offer no means for data comparison. To remedy this deficit we have devised the Synesthesia Battery. This unified collection of tests is freely accessible online (http://www.synesthete.org). It consists of a questionnaire and several online software programs, and test results are immediately available for use by synesthetes and invited researchers. Performance on the tests is quantified with a standard scoring system. We introduce several novel tests here, and offer the software for running the tests. By presenting standardized procedures for testing and comparing subjects, this endeavor hopes to speed scientific progress in synesthesia research. PMID:16919755
Double-Lap Shear Test For Honeycomb Core
NASA Technical Reports Server (NTRS)
Nettles, Alan T.; Hodge, Andrew J.
1992-01-01
Double-lap test measures shear strength of panel made of honeycomb core with 8-ply carbon-fiber/epoxy face sheets. Developed to overcome three principal disadvantages of prior standard single-lap shear test: specimen had to be more than 17 in. long; metal face sheets had to be used; and test introduced torque, with consequent bending and peeling of face sheets and spurious tensile or compressive loading of honeycomb.
An online ID identification system for liquefied-gas cylinder plant
NASA Astrophysics Data System (ADS)
He, Jin; Ding, Zhenwen; Han, Lei; Zhang, Hao
2017-11-01
An automatic ID identification system for gas cylinders' online production was developed based on the production conditions and requirements of the Technical Committee for Standardization of Gas Cylinders. A cylinder ID image acquisition system was designed to improve the image contrast of ID regions on gas cylinders against the background. Then the ID digits region was located by the CNN template matching algorithm. Following that, an adaptive threshold method based on the analysis of local average grey value and standard deviation was proposed to overcome defects of non-uniform background in the segmentation results. To improve the single digit identification accuracy, two BP neural networks were trained respectively for the identification of all digits and the easily confusable digits. If the single digit was classified as one of confusable digits by the former BP neural network, it was further tested by the later one, and the later result was taken as the final identification result of this single digit. At last, the majority voting was adopted to decide the final identification result for the 6-digit cylinder ID. The developed system was installed on a production line of a liquefied-petroleum-gas cylinder plant and worked in parallel with the existing weighing step on the line. Through the field test, the correct identification rate for single ID digit was 94.73%, and none of the tested 2000 cylinder ID was misclassified through the majority voting.
An Enclosed Laser Calibration Standard
NASA Astrophysics Data System (ADS)
Adams, Thomas E.; Fecteau, M. L.
1985-02-01
We have designed, evaluated and calibrated an enclosed, safety-interlocked laser calibration standard for use in US Army Secondary Reference Calibration Laboratories. This Laser Test Set Calibrator (LTSC) represents the Army's first-generation field laser calibration standard. Twelve LTSC's are now being fielded world-wide. The main requirement on the LTSC is to provide calibration support for the Test Set (TS3620) which, in turn, is a GO/NO GO tester of the Hand-Held Laser Rangefinder (AN/GVS-5). However, we believe it's design is flexible enough to accommodate the calibration of other laser test, measurement and diagnostic equipment (TMDE) provided that single-shot capability is adequate to perform the task. In this paper we describe the salient aspects and calibration requirements of the AN/GVS-5 Rangefinder and the Test Set which drove the basic LTSC design. Also, we detail our evaluation and calibration of the LTSC, in particular, the LTSC system standards. We conclude with a review of our error analysis from which uncertainties were assigned to the LTSC calibration functions.
NASA Astrophysics Data System (ADS)
Jara Casas, L. M.; Ceresa, D.; Kulis, S.; Miryala, S.; Christiansen, J.; Francisco, R.; Gnani, D.
2017-02-01
A Digital RADiation (DRAD) test chip has been specifically designed to study the impact of Total Ionizing Dose (TID) (<1 Grad) and Single Event Upset (SEU) on digital logic gates in a 65 nm CMOS technology. Nine different versions of standard cell libraries are studied in this chip, basically differing in the device dimensions, Vt flavor and layout of the device. Each library has eighteen test structures specifically designed to characterize delay degradation and power consumption of the standard cells. For SEU study, a dedicated test structure based on a shift register is designed for each library. TID results up to 500 Mrad are reported.
Arc fusion splicing of photonic crystal fibers to standard single mode fibers
NASA Astrophysics Data System (ADS)
Borzycki, Krzysztof; Kobelke, Jens; Schuster, Kay; Wójcik, Jan
2010-04-01
Coupling a photonic crystal fiber (PCF) to measuring instruments or optical subsystems is often done by splicing it to short lengths of single mode fiber (SMF) used for interconnections, as SMF is standardized, widely available and compatible with most fiber optic components and measuring instruments. This paper presents procedures and results of loss measurements during fusion splicing of five PCFs tested at NIT laboratory within activities of COST Action 299 "FIDES". Investigated silica-based fibers had 80-200 μm cladding diameter and were designed as single mode. A standard splicing machine designed for telecom fibers was used, but splicing procedure and arc power were tailored to each PCF. Splice loss varied between 0.7 and 2.8 dB at 1550 nm. Splices protected with heat-shrinkable sleeves served well for gripping fibers during mechanical tests and survived temperature cycling from -30°C to +70°C with stable loss. Collapse of holes in the PCF was limited by reducing fusion time to 0.2-0.5 s; additional measures included reduction of discharge power and shifting SMF-PCF contact point away from the axis of electrodes. Unfortunately, short fusion time sometimes precluded proper smoothing of glass surface, leading to a trade-off between splice loss and strength.
Evidence of Shifting Standards in Judgments of Male and Female Parents' Job-Related Ability
ERIC Educational Resources Information Center
Fuegen, Kathleen; Endicott, Nicole F.
2010-01-01
We tested the hypothesis, derived from the shifting standards model of stereotyping, that parenthood would polarize judgments of men's and women's job-related ability. One hundred thirty-five attorneys evaluated the resume of a recent law school graduate. The resume depicted the graduate as male or female and as either single or married with two…
Effects of Vigorous Intensity Physical Activity on Mathematics Test Performance
ERIC Educational Resources Information Center
Phillips, David S.; Hannon, James C.; Castelli, Darla M.
2015-01-01
The effect of an acute bout of physical activity on academic performance in school-based settings is under researched. The purpose of this study was to examine associations between a single, vigorous (70-85%) bout of physical activity completed during physical education on standardized mathematics test performance among 72, eighth grade students…
76 FR 31453 - Special Conditions: Gulfstream Model GVI Airplane; Single-Occupant Side-Facing Seats
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-01
.... SID TTI data must be processed as defined in Federal Motor Vehicle Safety Standard (FMVSS) part 571...). Pass/fail injury assessments: TTI and pelvic acceleration. 2. One longitudinal test with the Hybrid II... pelvic acceleration. 3. Vertical (14g) test with modified Hybrid II ATDs using existing pass/fail...
Phinney, Karen W; Sempos, Christopher T; Tai, Susan S-C; Camara, Johanna E; Wise, Stephen A; Eckfeldt, John H; Hoofnagle, Andrew N; Carter, Graham D; Jones, Julia; Myers, Gary L; Durazo-Arvizu, Ramon; Miller, W Greg; Bachmann, Lorin M; Young, Ian S; Pettit, Juanita; Caldwell, Grahame; Liu, Andrew; Brooks, Stephen P J; Sarafin, Kurtis; Thamm, Michael; Mensink, Gert B M; Busch, Markus; Rabenberg, Martina; Cashman, Kevin D; Kiely, Mairead; Galvin, Karen; Zhang, Joy Y; Kinsella, Michael; Oh, Kyungwon; Lee, Sun-Wha; Jung, Chae L; Cox, Lorna; Goldberg, Gail; Guberg, Kate; Meadows, Sarah; Prentice, Ann; Tian, Lu; Brannon, Patsy M; Lucas, Robyn M; Crump, Peter M; Cavalier, Etienne; Merkel, Joyce; Betz, Joseph M
2017-09-01
The Vitamin D Standardization Program (VDSP) coordinated a study in 2012 to assess the commutability of reference materials and proficiency testing/external quality assurance materials for total 25-hydroxyvitamin D [25(OH)D] in human serum, the primary indicator of vitamin D status. A set of 50 single-donor serum samples as well as 17 reference and proficiency testing/external quality assessment materials were analyzed by participating laboratories that used either immunoassay or LC-MS methods for total 25(OH)D. The commutability test materials included National Institute of Standards and Technology Standard Reference Material 972a Vitamin D Metabolites in Human Serum as well as materials from the College of American Pathologists and the Vitamin D External Quality Assessment Scheme. Study protocols and data analysis procedures were in accordance with Clinical and Laboratory Standards Institute guidelines. The majority of the test materials were found to be commutable with the methods used in this commutability study. These results provide guidance for laboratories needing to choose appropriate reference materials and select proficiency or external quality assessment programs and will serve as a foundation for additional VDSP studies.
Capacity, consent, and mental health legislation: time for a new standard?
O'Brien, Anthony J
2010-01-01
Recent international reforms in mental health legislation have introduced a capacity test as a criterion for civil commitment. There are proposals that a common test of incapacity should apply in both mental and physical health under a single legislative framework for all cases in which the normally accepted standard of informed consent for treatment is not met. Capacity is a complex concept, but can be reliably assessed in clinical practice. Nurses need to be involved in the policy debate about capacity and consent in mental health care.
Fullagar, Hugh H K; Sampson, John A; Mott, Brendan J; Burdon, Catriona A; Taylor, Nigel A S; Groeller, Herbert
2015-10-01
Firefighter physical aptitude tests were administered to unskilled subjects and operational firefighters to evaluate the impact that testing bias associated with gender, age, activity-specific skills, or task familiarity may have upon establishing performance thresholds. These tests were administered in sequence, simulating hazmat incidents, ventilation fan carriage (stairs), motor-vehicle rescues, bushfire incidents, fire attacks, and a firefighter rescue. Participants included two unskilled samples (N = 14 and 22) and 143 firefighters. Firefighter performance was not significantly different from the unskilled subjects. Participants from both genders passed the test, with scores unrelated to performance skill or age; however, familiarization significantly improved performance when the test was repeated. These outcomes confirmed this test to be gender-, age-, and skill-neutral. Familiarization effects could be removed through performing a single, pre-selection trial of the test battery.
Single Event Effect (SEE) Test Planning 101
NASA Technical Reports Server (NTRS)
LaBel, Kenneth A.; Pellish, Jonathan; Berg, Melanie D.
2011-01-01
This is a course on SEE Test Plan development. It is an introductory discussion of the items that go into planning an SEE test that should complement the SEE test methodology used. Material will only cover heavy ion SEE testing and not proton, LASER, or other though many of the discussed items may be applicable. While standards and guidelines for how-to perform single event effects (SEE) testing have existed almost since the first cyclotron testing, guidance on the development of SEE test plans has not been as easy to find. In this section of the short course, we attempt to rectify this lack. We consider the approach outlined here as a "living" document: mission specific constraints and new technology related issues always need to be taken into account. We note that we will use the term "test planning" in the context of those items being included in a test plan.
Visual memories for perceived length are well preserved in older adults.
Norman, J Farley; Holmin, Jessica S; Bartholomew, Ashley N
2011-09-15
Three experiments compared younger (mean age was 23.7years) and older (mean age was 72.1years) observers' ability to visually discriminate line length using both explicit and implicit standard stimuli. In Experiment 1, the method of constant stimuli (with an explicit standard) was used to determine difference thresholds, whereas the method of single stimuli (where the knowledge of the standard length was only implicit and learned from previous test stimuli) was used in Experiments 2 and 3. The study evaluated whether increases in age affect older observers' ability to learn, retain, and utilize effective implicit visual standards. Overall, the observers' length difference thresholds were 5.85% of the standard when the method of constant stimuli was used and improved to 4.39% of the standard for the method of single stimuli (a decrease of 25%). Both age groups performed similarly in all conditions. The results demonstrate that older observers retain the ability to create, remember, and utilize effective implicit standards from a series of visual stimuli. Copyright © 2011 Elsevier Ltd. All rights reserved.
BARTTest: Community-Standard Atmospheric Radiative-Transfer and Retrieval Tests
NASA Astrophysics Data System (ADS)
Harrington, Joseph; Himes, Michael D.; Cubillos, Patricio E.; Blecic, Jasmina; Challener, Ryan C.
2018-01-01
Atmospheric radiative transfer (RT) codes are used both to predict planetary and brown-dwarf spectra and in retrieval algorithms to infer atmospheric chemistry, clouds, and thermal structure from observations. Observational plans, theoretical models, and scientific results depend on the correctness of these calculations. Yet, the calculations are complex and the codes implementing them are often written without modern software-verification techniques. The community needs a suite of test calculations with analytically, numerically, or at least community-verified results. We therefore present the Bayesian Atmospheric Radiative Transfer Test Suite, or BARTTest. BARTTest has four categories of tests: analytically verified RT tests of simple atmospheres (single line in single layer, line blends, saturation, isothermal, multiple line-list combination, etc.), community-verified RT tests of complex atmospheres, synthetic retrieval tests on simulated data with known answers, and community-verified real-data retrieval tests.BARTTest is open-source software intended for community use and further development. It is available at https://github.com/ExOSPORTS/BARTTest. We propose this test suite as a standard for verifying atmospheric RT and retrieval codes, analogous to the Held-Suarez test for general circulation models. This work was supported by NASA Planetary Atmospheres grant NX12AI69G, NASA Astrophysics Data Analysis Program grant NNX13AF38G, and NASA Exoplanets Research Program grant NNX17AB62G.
Single Circuit Board Implementation of a Digitally Compensated SAW Oscillator (DCSO).
1983-12-01
Through this project a design for a Digitally Compensated SAW Oscillator (DCSO) was developed and implemented on a single circuit board. The AFIT IC, which...is the heart of the design , did not function properly. Therefore, my work was halted after testing several of the subcircuits and assembling the...o.... -7 Standards ........ o..o....... -8 Approach-9 Sequence of Presentation .................. -10 II, Design
Polyarylenethioethersulfone Membranes for Fuel Cells (Postprint)
2010-01-01
The Electrochemical SocietyProton exchange membrane fuel cells PEMFCs are an attrac- tive power source due to their energy efficiency and...standard in PEMFC technology.3,4 Nafion membranes have a polytetrafluoro- ethylene PTFE backbone, which provides thermal and chemical stability, and...diffusion layers to fabricate MEAs. Single-cell test (H- PEMFC ).— MEAs were positioned in a single-cell fixture with graphite blocks as current
Elsner, Peter; Seyfarth, Florian; Sonsmann, Flora; Strunk, Meike; John, Swen-Malte; Diepgen, Thomas; Schliemann, Sibylle
2013-10-01
In order to assess the cleaning efficacy of occupational skin cleansers, standardized test dirts mimicking the spectrum of skin soiling at dirty workplaces are necessary. To validate newly developed standardized test dirts (compliant with the EU Cosmetics Directive) for their occupational relevance. In this single-blinded, monocentric questionnaire-based clinical trial, 87 apprentices of three trades (household management; house painting and varnishing; and metal processing) evaluated the cleanability of six standardized test dirts in relation to their workplace dirts. In addition, they judged the similarity of the test dirts to actual dirts encountered in their working environments. Most of the household management participants assessed the hydrophilic model dirt ('mascara'), the lipophilic model dirt ('W/O cream') and a film-forming model dirt ('disperse paint') as best resembling the dirts found at their workplaces. Most of the painters and varnishers judged the filmogenic model dirts ('disperse paint' and 'acrylic paint') as best resembling the dirts found at their workplaces. For the metal workers, the lipophilic and paste-like model dirts were most similar to their workplace dirts. The spectrum of standardized test dirts developed represents well the dirts encountered at various workplaces. The test dirts may be useful in the development and in vivo efficacy testing of occupational skin cleansers. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Influence of different adhesive systems on the pull-out bond strength of glass fiber posts.
da Silva, Luciana Mendonça; Andrade, Andréa Mello de; Machuca, Melissa Fernanda Garcia; da Silva, Paulo Maurício Batista; da Silva, Ricardo Virgolino C; Veronezi, Maria Cecília
2008-01-01
This in vitro study evaluated the tensile bond strength of glass fiber posts (Reforpost - Angelus-Brazil) cemented to root dentin with a resin cement (RelyX ARC - 3M/ESPE) associated with two different adhesive systems (Adper Single Bond - 3M/ESPE and Adper Scotchbond Multi Purpose (MP) Plus - 3M/ESPE), using the pull-out test. Twenty single-rooted human teeth with standardized root canals were randomly assigned to 2 groups (n=10): G1- etching with 37% phosphoric acid gel (3M/ESPE) + Adper Single Bond + #1 post (Reforpost - Angelus) + four #1 accessory posts (Reforpin - Angelus) + resin cement; G2- etching with 37% phosphoric acid gel + Adper Scotchbond MP Plus + #1 post + four #1 accessory posts + resin cement. The specimens were stored in distilled water at 37 degrees C for 7 days and submitted to the pull-out test in a universal testing machine (EMIC) at a crosshead speed of 0.5 mm/min. The mean values of bond strength (kgf) and standard deviation were: G1- 29.163 +/- 7.123; G2- 37.752 +/-13.054. Statistical analysis (Student's t-test; a=0.05 showed no statistically significant difference (p<0.05) between the groups. Adhesive bonding failures between resin cement and root canal dentin surface were observed in both groups, with non-polymerized resin cement in the apical portion of the post space when Single Bond was used (G1). The type of adhesive system employed on the fiber post cementation did not influence the pull-out bond strength.
ERIC Educational Resources Information Center
Fenton, Ray; Stofflet, Fred; Straugh, Tom
This paper reports the creation, implementation, and discontinuation of a standards based spelling assessment program in Anchorage, Alaska. The program was initiated by the Anchorage school board as part of establishing district-wide performance goals for students in 1998-1999. Spelling was singled out for attention because of national discussions…
ERIC Educational Resources Information Center
Bracco, Kathy Reeves; Dadgar, Mina; Austin, Kim; Klarin, Becca; Broek, Marie; Finkelstein, Neal; Mundry, Susan; Bugler, Dan
2014-01-01
"Core to College: Preparing Students for College Readiness and Success" is a three-year initiative. The initiative's mission is to "facilitate greater coordination between K-12 and postsecondary education systems around implementation of the Common Core State Standards (CCSS) and aligned assessments." Its aim is to foster…
Study of materials for space processing
NASA Technical Reports Server (NTRS)
Lal, R. B.
1975-01-01
Materials were selected for device applications and their commercial use. Experimental arrangements were also made for electrical characterization of single crystals using electrical resistivity and Hall effect measurements. The experimental set-up was tested with some standard samples.
40 CFR 86.312-79 - Dynamometer and engine equipment specifications.
Code of Federal Regulations, 2011 CFR
2011-07-01
... test stand and other instruments for measurement of power output shall be accurate to within 2 percent... system must have a single tail pipe. For engines designed for a dual exhaust system, a standard or...
Automatic sleep stage classification using two facial electrodes.
Virkkala, Jussi; Velin, Riitta; Himanen, Sari-Leena; Värri, Alpo; Müller, Kiti; Hasan, Joel
2008-01-01
Standard sleep stage classification is based on visual analysis of central EEG, EOG and EMG signals. Automatic analysis with a reduced number of sensors has been studied as an easy alternative to the standard. In this study, a single-channel electro-oculography (EOG) algorithm was developed for separation of wakefulness, SREM, light sleep (S1, S2) and slow wave sleep (S3, S4). The algorithm was developed and tested with 296 subjects. Additional validation was performed on 16 subjects using a low weight single-channel Alive Monitor. In the validation study, subjects attached the disposable EOG electrodes themselves at home. In separating the four stages total agreement (and Cohen's Kappa) in the training data set was 74% (0.59), in the testing data set 73% (0.59) and in the validation data set 74% (0.59). Self-applicable electro-oculography with only two facial electrodes was found to provide reasonable sleep stage information.
Proton Particle Test Fluence: What's the Right Number?
NASA Technical Reports Server (NTRS)
LaBel, Kenneth A.; Ladbury, Raymond
2015-01-01
While we have been utilizing standard fluence levels such as those listed in the JESD57 document, we have begun revisiting what an appropriate test fluence is when it comes to qualifying a device for single events. Instead of a fixed fluence level or until a specific number of events occurs, a different thought process is required.
Particle Test Fluence: What's the Right Number?
NASA Technical Reports Server (NTRS)
LaBel, Kenneth A.
2014-01-01
While we have been utilizing standard fluence levels such as those listed in the JESD57 document, we have begun revisiting what an appropriate test fluence is when it comes to qualifying a device for single events. Instead of a fixed fluence level or until a specific number of events occurs, a different thought process is required.
Brogårdh, Christina; Lexell, Jan
2016-05-01
A new 13-item rating scale, the Self-Reported Impairments in Persons with Late Effects of Polio (SIPP), has been developed. The SIPP has been analyzed using the Rasch method and has shown good construct validity and internal consistency. To establish its clinical utility, further evaluation of its psychometric properties is needed. To evaluate the test-retest reliability of the SIPP and to define limits for the smallest change that indicates a real change, both for a group of persons and a single individual. A postal survey. University Hospital. Fifty-one persons (31 men and 20 women; mean age, 72 years) with clinically verified late effects of polio. Not applicable. The participants completed the SIPP twice, 2 weeks apart. The response frequencies at test occasion 1 (T1) and test occasion 2 (T2) were calculated. Test-retest reliability was analyzed using the percentage agreement of each item, the intraclass correlation coefficient, and the mean difference between the test occasions (đ), together with the 95% confidence intervals for đ, the standard error of measurement, the smallest real difference, and a Bland-Altman plot. The percentage agreement (ie, the same scoring at both test occasions) was >70% for 10 of 13 items. The mean score (standard deviation) was 27.9 (5.7) points at T1 and 28.2 (6.0) points at T2, with no systematic difference between the test occasions. The intraclass correlation coefficient was 0.88, the standard error of measurement (the smallest change for a group of persons) was 2.0 points, and the smallest real difference (the smallest change for a single individual) was 5.6 points, respectively. The SIPP is a reliable rating scale in persons with late effects of polio and can be used to evaluate effects of rehabilitation interventions and changes of perceived impairments over time both for a group of persons and for a single individual. Copyright © 2016 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Fu, Lin; Hu, Xiangyu Y.; Adams, Nikolaus A.
2017-12-01
We propose efficient single-step formulations for reinitialization and extending algorithms, which are critical components of level-set based interface-tracking methods. The level-set field is reinitialized with a single-step (non iterative) "forward tracing" algorithm. A minimum set of cells is defined that describes the interface, and reinitialization employs only data from these cells. Fluid states are extrapolated or extended across the interface by a single-step "backward tracing" algorithm. Both algorithms, which are motivated by analogy to ray-tracing, avoid multiple block-boundary data exchanges that are inevitable for iterative reinitialization and extending approaches within a parallel-computing environment. The single-step algorithms are combined with a multi-resolution conservative sharp-interface method and validated by a wide range of benchmark test cases. We demonstrate that the proposed reinitialization method achieves second-order accuracy in conserving the volume of each phase. The interface location is invariant to reapplication of the single-step reinitialization. Generally, we observe smaller absolute errors than for standard iterative reinitialization on the same grid. The computational efficiency is higher than for the standard and typical high-order iterative reinitialization methods. We observe a 2- to 6-times efficiency improvement over the standard method for serial execution. The proposed single-step extending algorithm, which is commonly employed for assigning data to ghost cells with ghost-fluid or conservative interface interaction methods, shows about 10-times efficiency improvement over the standard method while maintaining same accuracy. Despite their simplicity, the proposed algorithms offer an efficient and robust alternative to iterative reinitialization and extending methods for level-set based multi-phase simulations.
Combat Helmet-Headform Coupling Characterized from Blunt Impact Events
2011-11-01
Testing was completed on a monorail drop tower to analyze the effect of helmet/headform coupling on the blunt impact behavior of ACH helmets using FMVSS...designates its own methods and test equipment: a drop tower ( monorail or twin- wire), headform (DOT, ISO, NOCSAE), headform CG accelerometer (single or...the more anthropomorphic International Standard Organization (ISO) half headform. Testing was completed on a monorail drop tower to analyze the effect
The History of a Decision: A Standard Vibration Test Method for Qualification
Rizzo, Davinia; Blackburn, Mark
2017-01-01
As Mil-Std-810G and subsequent versions have included multiple degree of freedom vibration test methodologies, it is important to understand the history and factors that drove the original decision in Mil-Std-810 to focus on single degree of freedom (SDOF) vibration testing. By assessing the factors and thought process of early Mil-Std-810 vibration test methods, it enables one to better consider the use of multiple degree of freedom testing now that it is feasible with today’s technology and documented in Mil-Std-810. This paper delves into the details of the decision made in the 1960s for the SDOF vibration testing standards in Mil-Std-810more » beyond the limitations of technology at the time. We also consider the implications for effective test planning today considering the advances in test capabilities and improvements in understanding of the operational environment.« less
The History of a Decision: A Standard Vibration Test Method for Qualification
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rizzo, Davinia; Blackburn, Mark
As Mil-Std-810G and subsequent versions have included multiple degree of freedom vibration test methodologies, it is important to understand the history and factors that drove the original decision in Mil-Std-810 to focus on single degree of freedom (SDOF) vibration testing. By assessing the factors and thought process of early Mil-Std-810 vibration test methods, it enables one to better consider the use of multiple degree of freedom testing now that it is feasible with today’s technology and documented in Mil-Std-810. This paper delves into the details of the decision made in the 1960s for the SDOF vibration testing standards in Mil-Std-810more » beyond the limitations of technology at the time. We also consider the implications for effective test planning today considering the advances in test capabilities and improvements in understanding of the operational environment.« less
Critical Joints in Large Composite Primary Aircraft Structures. Volume 3: Ancillary Test Results
NASA Technical Reports Server (NTRS)
Bunin, Bruce L.; Sagui, R. L.
1985-01-01
A program was conducted to develop the technology for critical structural joints for composite wing structure that meets all the design requirements of a 1990 commercial transport aircraft. The results of a comprehensive ancillary test program are summarized, consisting of single-bolt composite joint specimens tested in a variety of configurations. These tests were conducted to characterize the strength and load deflection properties that are required for multirow joint analysis. The composite material was Toray 300 fiber and Ciba-Geigy 914 resin, in the form of 0.005 and 0.01 inch thick unidirectional tape. Tests were conducted in single and double shear for loaded and unloaded hole configurations under both tensile and compressive loading. Two different layup patterns were examined. All tests were conducted at room temperature. In addition, the results of NASA Standard Toughness Test (NASA RP 1092) are reported, which were conducted for several material systems.
Classifier for gravitational-wave inspiral signals in nonideal single-detector data
NASA Astrophysics Data System (ADS)
Kapadia, S. J.; Dent, T.; Dal Canton, T.
2017-11-01
We describe a multivariate classifier for candidate events in a templated search for gravitational-wave (GW) inspiral signals from neutron-star-black-hole (NS-BH) binaries, in data from ground-based detectors where sensitivity is limited by non-Gaussian noise transients. The standard signal-to-noise ratio (SNR) and chi-squared test for inspiral searches use only properties of a single matched filter at the time of an event; instead, we propose a classifier using features derived from a bank of inspiral templates around the time of each event, and also from a search using approximate sine-Gaussian templates. The classifier thus extracts additional information from strain data to discriminate inspiral signals from noise transients. We evaluate a random forest classifier on a set of single-detector events obtained from realistic simulated advanced LIGO data, using simulated NS-BH signals added to the data. The new classifier detects a factor of 1.5-2 more signals at low false positive rates as compared to the standard "reweighted SNR" statistic, and does not require the chi-squared test to be computed. Conversely, if only the SNR and chi-squared values of single-detector events are available, random forest classification performs nearly identically to the reweighted SNR.
Development of a reference material of a single DNA molecule for the quality control of PCR testing.
Mano, Junichi; Hatano, Shuko; Futo, Satoshi; Yoshii, Junji; Nakae, Hiroki; Naito, Shigehiro; Takabatake, Reona; Kitta, Kazumi
2014-09-02
We developed a reference material of a single DNA molecule with a specific nucleotide sequence. The double-strand linear DNA which has PCR target sequences at the both ends was prepared as a reference DNA molecule, and we named the PCR targets on each side as confirmation sequence and standard sequence. The highly diluted solution of the reference molecule was dispensed into 96 wells of a plastic PCR plate to make the average number of molecules in a well below one. Subsequently, the presence or absence of the reference molecule in each well was checked by real-time PCR targeting for the confirmation sequence. After an enzymatic treatment of the reaction mixture in the positive wells for the digestion of PCR products, the resultant solution was used as the reference material of a single DNA molecule with the standard sequence. PCR analyses revealed that the prepared samples included only one reference molecule with high probability. The single-molecule reference material developed in this study will be useful for the absolute evaluation of a detection limit of PCR-based testing methods, the quality control of PCR analyses, performance evaluations of PCR reagents and instruments, and the preparation of an accurate calibration curve for real-time PCR quantitation.
Field Testing of Compartmentalization Methods for Multifamily Construction
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ueno, K.; Lstiburek, J. W.
2015-03-01
The 2012 International Energy Conservation Code (IECC) has an airtightness requirement of 3 air changes per hour at 50 Pascals test pressure (3 ACH50) for single-family and multifamily construction (in climate zones 3–8). The Leadership in Energy & Environmental Design certification program and ASHRAE Standard 189 have comparable compartmentalization requirements. ASHRAE Standard 62.2 will soon be responsible for all multifamily ventilation requirements (low rise and high rise); it has an exceptionally stringent compartmentalization requirement. These code and program requirements are driving the need for easier and more effective methods of compartmentalization in multifamily buildings.
Insights from analysis for harmful and potentially harmful constituents (HPHCs) in tobacco products.
Oldham, Michael J; DeSoi, Darren J; Rimmer, Lonnie T; Wagner, Karl A; Morton, Michael J
2014-10-01
A total of 20 commercial cigarette and 16 commercial smokeless tobacco products were assayed for 96 compounds listed as harmful and potentially harmful constituents (HPHCs) by the US Food and Drug Administration. For each product, a single lot was used for all testing. Both International Organization for Standardization and Health Canada smoking regimens were used for cigarette testing. For those HPHCs detected, measured levels were consistent with levels reported in the literature, however substantial assay variability (measured as average relative standard deviation) was found for most results. Using an abbreviated list of HPHCs, statistically significant differences for most of these HPHCs occurred when results were obtained 4-6months apart (i.e., temporal variability). The assay variability and temporal variability demonstrate the need for standardized analytical methods with defined repeatability and reproducibility for each HPHC using certified reference standards. Temporal variability also means that simple conventional comparisons, such as two-sample t-tests, are inappropriate for comparing products tested at different points in time from the same laboratory or from different laboratories. Until capable laboratories use standardized assays with established repeatability, reproducibility, and certified reference standards, the resulting HPHC data will be unreliable for product comparisons or other decision making in regulatory science. Copyright © 2014 Elsevier Inc. All rights reserved.
Assessment of bifacial photovoltaic module power rating methodologies–inside and out
Deline, Chris; MacAlpine, Sara; Marion, Bill; ...
2017-01-26
One-sun power ratings for bifacial modules are currently undefined. This is partly because there is no standard definition of rear irradiance given 1000 W·m -2 on the front. Using field measurements and simulations, we evaluate multiple deployment scenarios for bifacial modules and provide details on the amount of irradiance that could be expected. A simplified case that represents a single module deployed under conditions consistent with existing one-sun irradiance standards lead to a bifacial reference condition of 1000 W·m -2 G front and 130-140 W·m -2 G rear. For fielded systems of bifacial modules, Grear magnitude and spatial uniformity willmore » be affected by self-shade from adjacent modules, varied ground cover, and ground-clearance height. A standard measurement procedure for bifacial modules is also currently undefined. A proposed international standard is under development, which provides the motivation for this paper. Here, we compare field measurements of bifacial modules under natural illumination with proposed indoor test methods, where irradiance is only applied to one side at a time. The indoor method has multiple advantages, including controlled and repeatable irradiance and thermal environment, along with allowing the use of conventional single-sided flash test equipment. The comparison results are promising, showing that indoor and outdoor methods agree within 1%-2% for multiple rear-irradiance conditions and bifacial module construction. Furthermore, a comparison with single-diode theory also shows good agreement to indoor measurements, within 1%-2% for power and other current-voltage curve parameters.« less
Improved auscultation skills in paramedic students using a modified stethoscope.
Simon, Erin L; Lecat, Paul J; Haller, Nairmeen A; Williams, Carolyn J; Martin, Scott W; Carney, John A; Pakiela, John A
2012-12-01
The Ventriloscope® (Lecat's SimplySim, Tallmadge, OH) is a modified stethoscope used as a simulation training device for auscultation. To test the effectiveness of the Ventriloscope as a training device in teaching heart and lung auscultatory findings to paramedic students. A prospective, single-hospital study conducted in a paramedic-teaching program. The standard teaching group learned heart and lung sounds via audiocassette recordings and lecture, whereas the intervention group utilized the modified stethoscope in conjunction with patient volunteers. Study subjects took a pre-test, post-test, and a follow-up test to measure recognition of heart and lung sounds. The intervention group included 22 paramedic students and the standard group included 18 paramedic students. Pre-test scores did not differ using two-sample t-tests (standard group: t [16]=-1.63, p=0.12) and (intervention group: t [20]=-1.17, p=0.26). Improvement in pre-test to post-test scores was noted within each group (standard: t [17]=2.43, p=0.03; intervention: t [21]=4.81, p<0.0001). Follow-up scores for the standard group were not different from pre-test scores of 16.06 (t [17]=0.94, p=0.36). However, follow-up scores for the intervention group significantly improved from their respective pre-test score of 16.05 (t [21]=2.63, p=0.02). Simulation training using a modified stethoscope in conjunction with standardized patients allows for realistic learning of heart and lung sounds. This technique of simulation training achieved proficiency and better retention of heart and lung sounds in a safe teaching environment. Copyright © 2012 Elsevier Inc. All rights reserved.
Ortalli, Margherita; Attard, Luciano; Vanino, Elisa; Gaibani, Paolo; Vocale, Caterina; Rossini, Giada; Cagarelli, Roberto; Pierro, Anna; Billi, Patrizia; Mastroianni, Antonio; Di Cesare, Simona; Codeluppi, Mauro; Franceschini, Erica; Melchionda, Fraia; Gramiccia, Marina; Scalone, Aldo; Gentilomi, Giovanna A.; Landini, Maria P.
2017-01-01
The diagnosis of visceral leishmaniasis (VL) remains challenging, due to the limited sensitivity of microscopy, the poor performance of serological methods in immunocompromised patients and the lack of standardization of molecular tests. The aim of this study was to implement a combined diagnostic workflow by integrating serological and molecular tests with standardized clinical criteria. Between July 2013 and June 2015, the proposed workflow was applied to specimens obtained from 94 in-patients with clinical suspicion of VL in the Emilia-Romagna region, Northern Italy. Serological tests and molecular techniques were employed. Twenty-one adult patients (22%) had a confirmed diagnosis of VL by clinical criteria, serology and/or real-time polymerase chain reaction; 4 of these patients were HIV-positive. Molecular tests exhibited higher sensitivity than serological tests for the diagnosis of VL. In our experience, the rK39 immunochromatographic test was insufficiently sensitive for use as a screening test for the diagnosis of VL caused by L. infantum in Italy. However, as molecular tests are yet not standardized, further studies are required to identify an optimal screening test for Mediterranean VL. PMID:28832646
Evaluation of the Commercial, Off-the-Shelf (COTS) King-Devick Eye Tracking System
duty decisions. The current literature suggests that the King Devick (KD) number reading test is a sensitive screener for concussion sustained during...sports activities. The KD test involves timing an individual reading aloud 120 single digit numbers, without error, printed on three standard cards...timing is performed with a stopwatch. The extensive literature commonly describes the KD test as revealing the disruption of eye movements that could be
Riedl, Verena; Agatz, Annika; Benstead, Rachel; Ashauer, Roman
2018-04-01
Chemical impacts on the environment are routinely assessed in single-species tests. They are employed to measure direct effects on nontarget organisms, but indirect effects on ecological interactions can only be detected in multispecies tests. Micro- and mesocosms are more complex and environmentally realistic, yet they are less frequently used for environmental risk assessment because resource demand is high, whereas repeatability and statistical power are often low. Test systems fulfilling regulatory needs (i.e., standardization, repeatability, and replication) and the assessment of impacts on species interactions and indirect effects are lacking. In the present study we describe the development of the TriCosm, a repeatable aquatic multispecies test with 3 trophic levels and increased statistical power. High repeatability of community dynamics of 3 interacting aquatic populations (algae, Ceriodaphnia, and Hydra) was found with an average coefficient of variation of 19.5% and the ability to determine small effect sizes. The TriCosm combines benefits of both single-species tests (fulfillment of regulatory requirements) and complex multispecies tests (ecological relevance) and can be used, for instance, at an intermediate tier in environmental risk assessment. Furthermore, comparatively quickly generated population and community toxicity data can be useful for the development and testing of mechanistic effect models. Environ Toxicol Chem 2018;37:1051-1060. © 2017 SETAC. © 2017 SETAC.
2009-01-01
Background The aim of this study was to compare the pharmacokinetic properties of sodium ibuprofen and ibuprofen acid incorporating poloxamer with standard ibuprofen acid tablets. Methods Twenty-two healthy volunteers were enrolled into this randomised, single-dose, 3-way crossover, open-label, single-centre, pharmacokinetic study. After 14 hours' fasting, participants received a single dose of 2 × 200 mg ibuprofen acid tablets (standard ibuprofen), 2 × 256 mg ibuprofen sodium dihydrate tablets (sodium ibuprofen; each equivalent to 200 mg ibuprofen acid) and 2 × 200 mg ibuprofen acid incorporating 60 mg poloxamer 407 (ibuprofen/poloxamer). A washout period of 2-7 days separated consecutive dosing days. On each of the 3 treatment days, blood samples were collected post dose for pharmacokinetic analyses and any adverse events recorded. Plasma concentration of ibuprofen was assessed using a liquid chromatographic-mass spectrometry procedure in negative ion mode. A standard statistical ANOVA model, appropriate for bioequivalence studies, was used and ratios of 90% confidence intervals (CIs) were calculated. Results Tmax for sodium ibuprofen was less than half that of standard ibuprofen (median 35 min vs 90 min, respectively; P = 0.0002) and Cmax was significantly higher (41.47 μg/mL vs 31.88 μg/mL; ratio test/reference = 130.06%, 90% CI 118.86-142.32%). Ibuprofen/poloxamer was bioequivalent to the standard ibuprofen formulation, despite its Tmax being on average 20 minutes shorter than standard ibuprofen (median 75 mins vs 90 mins, respectively; P = 0.1913), as the ratio of test/reference = 110.48% (CI 100.96-120.89%), which fell within the 80-125% limit of the CPMP and FDA guidelines for bioequivalence. The overall extent of absorption was similar for the three formulations, which were all well tolerated. Conclusion In terms of Tmax, ibuprofen formulated as a sodium salt was absorbed twice as quickly as from standard ibuprofen acid. The addition of poloxamer to ibuprofen acid did not significantly affect absorption. PMID:19961574
Single Event Effects (SEE) Testing: Practical Approach to Test Plans
NASA Technical Reports Server (NTRS)
LaBel, Kenneth A.; Pellish, Jonathan Allen; Berg, Melanie D.
2014-01-01
While standards and guidelines for performing SEE testing have existed for several decades, guidance for developing SEE test plans has not been as easy to find. In this presentation, the variety of areas that need to be considered ranging from resource issues (funds, personnel, schedule) to extremely technical challenges (particle interaction and circuit application), shall be discussed. Note: we consider the approach outlined here as a "living" document: Mission-specific constraints and new technology related issues always need to be taken into account.
A proton irradiation test facility for space research in Ankara, Turkey
NASA Astrophysics Data System (ADS)
Gencer, Ayşenur; Yiǧitoǧlu, Merve; Bilge Demirköz, Melahat; Efthymiopoulos, Ilias
2016-07-01
Space radiation often affects the electronic components' performance during the mission duration. In order to ensure reliable performance, the components must be tested to at least the expected dose that will be received in space, before the mission. Accelerator facilities are widely used for such irradiation tests around the world. Turkish Atomic Energy Authority (TAEA) has a 15MeV to 30MeV variable proton cyclotron in Ankara and the facility's main purpose is to produce radioisotopes in three different rooms for different target systems. There is also an R&D room which can be used for research purposes. This paper will detail the design and current state of the construction of a beamline to perform Single Event Effect (SEE) tests in Ankara for the first time. ESA ESCC No.25100 Standard Single Event Effect Test Method and Guidelines is being considered for these SEE tests. The proton beam kinetic energy must be between 20MeV and 200MeV according to the standard. While the proton energy is suitable for SEE tests, the beam size must be 15.40cm x 21.55cm and the flux must be between 10 ^{5} p/cm ^{2}/s to at least 10 ^{8} p/cm ^{2}/s according to the standard. The beam size at the entrance of the R&D room is mm-sized and the current is variable between 10μA and 1.2mA. Therefore, a defocusing beam line has been designed to enlarge the beam size and reduce the flux value. The beam line has quadrupole magnets to enlarge the beam size and the collimators and scattering foils are used for flux reduction. This facility will provide proton fluxes between 10 ^{7} p/cm ^{2}/s and 10 ^{10} p/cm ^{2}/s for the area defined in the standard when completed. Also for testing solar cells developed for space, the proton beam energy will be lowered below 10MeV. This project has been funded by Ministry of Development in Turkey and the beam line construction will finish in two years and SEE tests will be performed for the first time in Turkey.
Gradient microfluidics enables rapid bacterial growth inhibition testing.
Li, Bing; Qiu, Yong; Glidle, Andrew; McIlvenna, David; Luo, Qian; Cooper, Jon; Shi, Han-Chang; Yin, Huabing
2014-03-18
Bacterial growth inhibition tests have become a standard measure of the adverse effects of inhibitors for a wide range of applications, such as toxicity testing in the medical and environmental sciences. However, conventional well-plate formats for these tests are laborious and provide limited information (often being restricted to an end-point assay). In this study, we have developed a microfluidic system that enables fast quantification of the effect of an inhibitor on bacteria growth and survival, within a single experiment. This format offers a unique combination of advantages, including long-term continuous flow culture, generation of concentration gradients, and single cell morphology tracking. Using Escherichia coli and the inhibitor amoxicillin as one model system, we show excellent agreement between an on-chip single cell-based assay and conventional methods to obtain quantitative measures of antibiotic inhibition (for example, minimum inhibition concentration). Furthermore, we show that our methods can provide additional information, over and above that of the standard well-plate assay, including kinetic information on growth inhibition and measurements of bacterial morphological dynamics over a wide range of inhibitor concentrations. Finally, using a second model system, we show that this chip-based systems does not require the bacteria to be labeled and is well suited for the study of naturally occurring species. We illustrate this using Nitrosomonas europaea, an environmentally important bacteria, and show that the chip system can lead to a significant reduction in the period required for growth and inhibition measurements (<4 days, compared to weeks in a culture flask).
Polyarylenethioethersulfone Membranes for Fuel Cells (Postprint)
2007-09-01
2007. 0013-4651/2007/1549/B960/9/$20.00 © The Electrochemical SocietyProton exchange membrane fuel cells PEMFCs are an attrac- tive power source...DuPont have become the commercially available standard in PEMFC technology.3,4 Nafion membranes have a polytetrafluoro- ethylene PTFE backbone, which...Inc. were used as anode and cathode gas diffusion layers to fabricate MEAs. Single-cell test (H- PEMFC ).— MEAs were positioned in a single-cell fixture
Programs for Testing Processor-in-Memory Computing Systems
NASA Technical Reports Server (NTRS)
Katz, Daniel S.
2006-01-01
The Multithreaded Microbenchmarks for Processor-In-Memory (PIM) Compilers, Simulators, and Hardware are computer programs arranged in a series for use in testing the performances of PIM computing systems, including compilers, simulators, and hardware. The programs at the beginning of the series test basic functionality; the programs at subsequent positions in the series test increasingly complex functionality. The programs are intended to be used while designing a PIM system, and can be used to verify that compilers, simulators, and hardware work correctly. The programs can also be used to enable designers of these system components to examine tradeoffs in implementation. Finally, these programs can be run on non-PIM hardware (either single-threaded or multithreaded) using the POSIX pthreads standard to verify that the benchmarks themselves operate correctly. [POSIX (Portable Operating System Interface for UNIX) is a set of standards that define how programs and operating systems interact with each other. pthreads is a library of pre-emptive thread routines that comply with one of the POSIX standards.
Static tests of the propulsion system. [Propfan Test Assessment program
NASA Technical Reports Server (NTRS)
Withers, C. C.; Bartel, H. W.; Turnberg, J. E.; Graber, E. J.
1987-01-01
Advanced, highly-loaded, high-speed propellers, called propfans, are promising to revolutionize the transport aircraft industry by offering a 15- to 30-percent fuel savings over the most advanced turbofans without sacrificing passenger comfort or violating community noise standards. NASA Lewis Research Center and industry have been working jointly to develop the needed propfan technology. The NASA-funded Propfan Test Assessment (PTA) Program represents a key element of this joint program. In PTA, Lockheed-Georgia, working in concert with Hamilton Standard, Rohr Industries, Gulfstream Aerospace, and Allison, is developing a propfan propulsion system which will be mounted on the left wing of a modified Gulfstream GII aircraft and flight tested to verify the in-flight characteristics of a 9-foot diameter, single-rotation propfan. The propfan, called SR-7L, was designed and fabricated by Hamilton Standard under a separate NASA contract. Prior to flight testing, the PTA propulsion system was static tested at the Rohr Brown Field facility. In this test, propulsion system operational capability was verified and data was obtained on propfan structural response, system acoustic characteristics, and system performance. This paper reports on the results of the static tests.
Robles-Molina, José; Gilbert-López, Bienvenida; García-Reyes, Juan F; Molina-Díaz, Antonio
2017-09-29
Pesticide testing of foodstuffs is usually accomplished with generic wide-scope multi-residue methods based on liquid chromatography tandem mass spectrometry (LC-MS/MS). However, this approach does not cover some special pesticides, the so called "single-residue method" compounds, that are hardly compatible with standard reversed-phase (RP) separations due to their specific properties. In this article, we propose a comprehensive strategy for the integration of single residue method compounds and standard multiresidue pesticides within a single run. It is based on the use of a parallel LC column assembly with two different LC gradients performing orthogonal hydrophilic interaction chromatography (HILIC) and reversed-phase (RPLC) chromatography within one analytical run. Two sample aliquots were simultaneously injected on each column, using different gradients, being the eluents merged post-column prior to mass spectrometry detection. The approach was tested with 41 multiclass pesticides covering a wide range of physicochemical properties across several orders of log K ow (from -4 to +5.5). With this assembly, distinct separation from the void was attained for all the pesticides studied, keeping similar performance in terms of sensitivity, peak area reproducibility (<6 RSD% in most cases) and retention time stability of standard single column approaches (better than±0.1min). The application of the proposed approach using parallel HILIC/RPLC and RPLC/aqueous normal phase (Obelisc) were assessed in leek using LC-MS/MS. For this purpose, a hybrid QuEChERS (Quick, easy, cheap, effective, rugged and safe)/QuPPe (quick method for polar pesticides) method was evaluated based on solvent extraction with MeOH and acetonitrile followed by dispersive solid-phase extraction, delivering appropriate recoveries for most of the pesticides included in the study within the log K ow in the range from -4 to +5.5. The proposed strategy may be extended to other fields such as sport drug testing or environmental analysis, where the same type of variety of analytes featuring poor retention within a single chromatographic separation occurs. Copyright © 2017 Elsevier B.V. All rights reserved.
Multi-mesh gear dynamics program evaluation and enhancements
NASA Technical Reports Server (NTRS)
Boyd, L. S.; Pike, J.
1985-01-01
A multiple mesh gear dynamics computer program was continually developed and modified during the last four years. The program can handle epicyclic gear systems as well as single mesh systems with internal, buttress, or helical tooth forms. The following modifications were added under the current funding: variable contact friction, planet cage and ring gear rim flexibility options, user friendly options, dynamic side bands, a speed survey option and the combining of the single and multiple mesh options into one general program. The modified program was evaluated by comparing calculated values to published test data and to test data taken on a Hamilton Standard turboprop reduction gear-box. In general, the correlation between the test data and the analytical data is good.
Importance of ion energy on SEU in CMOS SRAMs
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dodd, P.E.; Shaneyfelt, M.R.; Sexton, F.W.
1998-03-01
The single-event upset (SEU) responses of 16 Kbit to 1 Mbit SRAMs irradiated with low and high-energy heavy ions are reported. Standard low-energy heavy ion tests appear to be sufficiently conservative for technologies down to 0.5 {micro}m.
A Minimal Optical Trapping and Imaging Microscopy System
Hernández Candia, Carmen Noemí; Tafoya Martínez, Sara; Gutiérrez-Medina, Braulio
2013-01-01
We report the construction and testing of a simple and versatile optical trapping apparatus, suitable for visualizing individual microtubules (∼25 nm in diameter) and performing single-molecule studies, using a minimal set of components. This design is based on a conventional, inverted microscope, operating under plain bright field illumination. A single laser beam enables standard optical trapping and the measurement of molecular displacements and forces, whereas digital image processing affords real-time sample visualization with reduced noise and enhanced contrast. We have tested our trapping and imaging instrument by measuring the persistence length of individual double-stranded DNA molecules, and by following the stepping of single kinesin motor proteins along clearly imaged microtubules. The approach presented here provides a straightforward alternative for studies of biomaterials and individual biomolecules. PMID:23451216
Hansen, Marten; Varga, Eszter; Aarts, Cathelijn; Wust, Tatjana; Kuijpers, Taco; von Lindern, Marieke; van den Akker, Emile
2018-04-28
Hematopoietic differentiation of human induced pluripotent stem cells (iPSCs) provide opportunities not only for fundamental research and disease modelling/drug testing but also for large-scale production of blood effector cells for future clinical application. Although there are multiple ways to differentiate human iPSCs towards hematopoietic lineages, there is a need to develop reproducible and robust protocols. Here we introduce an efficient way to produce three major blood cell types using a standardized differentiation protocol that starts with a single hematopoietic initiation step. This system is feeder-free, avoids EB-formation, starts with a hematopoietic initiation step based on a novel single cell-derived iPSC colony differentiation and produces multi-potential progenitors within 8-10 days. Followed by lineage-specific growth factor supplementation these cells can be matured into well characterized erythroid, megakaryocytic and myeloid cells with high-purity, without transcription factor overexpression or any kind of pre-purification step. This standardized differentiation system provides a simple platform to produce specific blood cells in a reproducible manner for hematopoietic development studies, disease modelling, drug testing and the potential for future therapeutic applications. Copyright © 2018. Published by Elsevier B.V.
Giovacchini, Coral X; Mathews, Anne M; Lawlor, Brian R; MacIntyre, Neil R
2018-04-01
Oxygen supplementation for exercise-induced hypoxemia is a common clinical practice that improves exercise tolerance. However, we know of no standardized exercise oxygen titration protocol using a single walk test. We report our experience with a protocol developed in our laboratory. Our protocol is based on the 6-min walk test (6MWT). Pulse oximetry readings (oxygen saturation [Spo 2 ]) are monitored, and supplemental oxygen is added in 2 L/min increments to keep Spo 2 > 88%. This continues for at least 6 min of walking with the Spo 2 remaining > 88% for at least 3 min. The records of consecutive patients over 4 months undergoing this procedure were reviewed for test performance, oxygen titration results, and adverse events. Two hundred twenty-two patients were tested; only two prematurely terminated the protocol because of intractable dyspnea. One hundred fifty-six patients (38%) required oxygen supplementation, with the first titration most commonly occurring between 1 and 2 min of walking. Nine of the patients had the first titration after 5 min of walking. The average test duration was 7 min (maximum, 15 min). The average number of titrations was 2.2 (maximum six). Sixteen patients could not maintain Spo 2 > 88% for 3 min despite administration of 15 L/min of supplemental oxygen (maximal dose). Our protocol was easily performed as a modification of a standard 6MWT with no serious adverse events. Because it is based on a widely accepted measurement of functional capabilities, and because it determined a stable final oxygen dose for ≥ 3 min of walking in most patients, we believe this protocol can be easily adapted for clinical use. Copyright © 2017 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.
Tentolouris, Nikolaos; Kanellos, Panagiotis T; Siami, Evangelia; Athanasopoulou, Elpida; Chaviaras, Nikolaos; Kolovou, Genovefa; Sfikakis, Petros P; Katsilambros, Nikolaos
2017-08-01
Lipotest ® is a standardized fat-rich meal designed for use as a test meal during a fat tolerance test (FTT) for the study of postprandial triacylglycerol (TAG) concentrations. Herein we examined the precision and reproducibility of examination using Lipotest ® on postprandial TAG levels. A total of 26 healthy consenting subjects were examined twice after 8-10 h fasting with an interval of approximately 1 week apart. Blood samples were collected at baseline and 1, 2, 3, and 4 h after consumption of the test meal for measurement of plasma total TAG levels. We examined agreement, precision, and accuracy between the two visits using the Altman plots and correlation coefficient. Reproducibility was tested using the coefficient of variation (CV) and intraclass correlation coefficient (ICC). Moreover, the area under the curve (AUC) as a summary measure of the overall postprandial TAG levels was calculated. The agreement, precision (r ≥ 0.74, p < 0.001), and accuracy (≥0.99) between the measurements in plasma TAG during Lipotest ® testing in the two visits were high. In terms of reproducibility, the values of CV were 15.59-23.83% while those of ICC were ≥0.75. The values of the AUCs in the visits were not different (p = 0.87). A single measurement of plasma TAG levels at 4 h after Lipotest ® consumption depicted peak postprandial TAG concentration. A FTT using Lipotest ® as a standardized meal has good precision and reproducibility for the study of postprandial TAG levels in healthy individuals. A single determination of plasma TAG concentration at 4 h after Lipotest ® consumption captures peak postprandial TAG response.
NASA Astrophysics Data System (ADS)
Tiunov, V. V.
2018-02-01
The report provides results of the research related to the tubular linear induction motors’ application. The motors’ design features, a calculation model, a description of test specimens for mining and electric power industry are introduced. The most attention is given to the single-phase motors for high voltage switches drives with the usage of inexpensive standard single-phase transformers for motors’ power supply. The method of the motor’s parameters determination, when the motor is being fed from the transformer, working in the overload mode, was described, and the results of it practical usage were good enough for the engineering practice.
SMC Standard: Evaluation and Test Requirements for Liquid Rocket Engines
2017-07-26
Run -Time Trends .................................................................................................... 53 7.2.4 Steady State Analytical...Administration, 2008. 22. M. Singh, J. Vargo, D. Schiffer and J. Dello, “Safe Diagram – A Design and Reliability Tool for Turbine Blading ,” Dresser-Rand...allowed starts and run ‐time including ground acceptance testing, on‐pad firings/aborts, and flight exposure. Part: A single piece (or two or more
Shear bond strength of a new one-bottle dentin adhesive.
Swift, E J; Bayne, S C
1997-08-01
To test the shear bond strength of a new adhesive, 3M Single Bond, to dentin surfaces containing different degrees of moisture. Two commercially available one-bottle adhesives (Prime & Bond, One-Step) and a conventional three-step system (Scotchbond Multi-Purpose Plus) were included for comparison. 120 bovine teeth were embedded in acrylic and the labial surfaces were polished to 600 grit to create standardized dentin surfaces for testing. Resin composite was bonded to dentin using a gelatin capsule technique. Four adhesive systems were evaluated with three different degrees of surface moisture (moist, wet, and overwet). Shear bond strengths of adhesives to dentin were determined using a universal testing machine and analyzed by ANOVA and Tukey's post hoc tests. Single Bond had mean shear bond strengths of 19.2, 23.2 and 20.3 MPa to moist, wet, and overwet dentin, respectively. Bond strengths of the three-component system Scotchbond Multi-Purpose Plus ranged from 23.1 to 25.3 MPa, but were not significantly higher than the values for Single Bond. Prime & Bond had bond strengths similar to those of Single Bond, but One-Step had significantly lower bond strengths (P < 0.05) in the wet and overwet conditions.
Dotan, Raffy
2012-06-01
The multisession maximal lactate steady-state (MLSS) test is the gold standard for anaerobic threshold (AnT) estimation. However, it is highly impractical, requires high fitness level, and suffers additional shortcomings. Existing single-session AnT-estimating tests are of compromised validity, reliability, and resolution. The presented reverse lactate threshold test (RLT) is a single-session, AnT-estimating test, aimed at avoiding the pitfalls of existing tests. It is based on the novel concept of identifying blood lactate's maximal appearance-disappearance equilibrium by approaching the AnT from higher, rather than from lower exercise intensities. Rowing, cycling, and running case data (4 recreational and competitive athletes, male and female, aged 17-39 y) are presented. Subjects performed the RLT test and, on a separate session, a single 30-min MLSS-type verification test at the RLT-determined intensity. The RLT and its MLSS verification exhibited exceptional agreement at 0.5% discrepancy or better. The RLT's training sensitivity was demonstrated by a case of 2.5-mo training regimen following which the RLT's 15-W improvement was fully MLSS-verified. The RLT's test-retest reliability was examined in 10 trained and untrained subjects. Test 2 differed from test 1 by only 0.3% with an intraclass correlation of 0.997. The data suggest RLT to accurately and reliably estimate AnT (as represented by MLSS verification) with high resolution and in distinctly different sports and to be sensitive to training adaptations. Compared with MLSS, the single-session RLT is highly practical and its lower fitness requirements make it applicable to athletes and untrained individuals alike. Further research is needed to establish RLT's validity and accuracy in larger samples.
Airborne UV photon-counting radiometer
NASA Astrophysics Data System (ADS)
Bauer, Marc C.; Wilcher, George; Banks, Calvin R.; Wood, Ronald L.
2000-11-01
The radiometric measurements group at the Arnold Engineering Development Center (AEDC) has developed new solar-blind radiometers for the SENSOR TALON flight test. These radiometers will be flown in an instrument pod by the 46th Test Wing at Eglin AFB. The radiometers are required to fit into a single quadrant of a 22-in.-diam sphere turret of the instrument pod. Because of minimal space requirements and photon-counting sensitivity needs, the radiometric measurements group used image intensifiers instead of the standard photomultiplier tubes (PMTs). The new design concept improved the photon-counting sensitivity, dynamic range, and uniformity of the field of view as compared to standard PMTs. A custom data acquisition system was required to miniaturize the electronics and generate a pulse code-modulated (PCM) data stream to the standard tape recording system.
Sum and mean. Standard programs for activation analysis.
Lindstrom, R M
1994-01-01
Two computer programs in use for over a decade in the Nuclear Methods Group at NIST illustrate the utility of standard software: programs widely available and widely used, in which (ideally) well-tested public algorithms produce results that are well understood, and thereby capable of comparison, within the community of users. Sum interactively computes the position, net area, and uncertainty of the area of spectral peaks, and can give better results than automatic peak search programs when peaks are very small, very large, or unusually shaped. Mean combines unequal measurements of a single quantity, tests for consistency, and obtains the weighted mean and six measures of its uncertainty.
De Angelis C; Fattibene; Onori; Petetti; Bartolotta; Sansone Santamaria A
2000-05-01
Alanine-polyethylene solid state dosimeters were prepared at Istituto Superiore di Sanita (ISS) following the recipe proposed by National Institute of Standards and Technology (NIST) with the goal of testing its transferability. Dosimeters were prepared using 95% alanine and 5% polyethylene, by weight. They are rugged and of increased sensitivity, repeatability and reproducibility as respect to the ISS alanine-paraffin pellets. Reproducibility of about 1% was obtained at 10 Gy and at 3 Gy if one single pellet or a stack of five dosimeters were used, respectively.
Deployment of Directory Service for IEEE N Bus Test System Information
NASA Astrophysics Data System (ADS)
Barman, Amal; Sil, Jaya
2008-10-01
Exchanging information over Internet and Intranet becomes a defacto standard in computer applications, among various users and organizations. Distributed system study, e-governance etc require transparent information exchange between applications, constituencies, manufacturers, and vendors. To serve these purposes database system is needed for storing system data and other relevant information. Directory service, which is a specialized database along with access protocol, could be the single solution since it runs over TCP/IP, supported by all POSIX compliance platforms and is based on open standard. This paper describes a way to deploy directory service, to store IEEE n bus test system data and integrating load flow program with it.
Plom, W; Strike, S C; Taylor, M J D
2014-06-01
The aim of this study was to test the effect different unstable footwear constructions have on centre of pressure motion when standing. Sixteen young female volunteers were tested in five conditions, three unstable footwear (Reebok Easy-Tone, FitFlop and Skechers Shape-Ups), a standard shoe and barefoot in a randomised order. Double and single leg balance on a force plate was assessed via centre of pressure excursions and displacements in each condition. For double leg and single leg standing centre of pressure excursions in the anterior-posterior direction were significantly increased wearing Skechers Shape-Ups compared to barefoot and the standard shoe. For the Reebok Easy Tone during single leg standing excursions in the anterior-posterior direction were significantly greater compared to the barefoot condition. Cumulative displacement of the centre of pressure in medial-lateral direction increased significantly during single leg standing when wearing Skechers Shape-Ups compared to barefoot and standard shoe as well as for Reebok Easy Tone vs. barefoot. It would appear from these quiet standing results that the manner of the construction of instability shoes effects the CoP movement which is associated with induced instability. Greater CoP excursion occurred in the A-P direction while the cumulative displacements were greater in the M-L direction for those shoes with the rounded sole and soft foam and those with airpods. The shoe construction with altered density foam did not induce any change in the CoP movement, during quite standing, which tends to suggest that it is not effective at inducing balance. Not all instability shoes are effective in altering the overall instability of the wearer. Copyright © 2014 Elsevier B.V. All rights reserved.
The clinical significance of 10-m walk test standardizations in Parkinson's disease.
Lindholm, Beata; Nilsson, Maria H; Hansson, Oskar; Hagell, Peter
2018-06-06
The 10-m walk test (10MWT) is a widely used measure of gait speed in Parkinson's disease (PD). However, it is unclear if different standardizations of its conduct impact test results. We examined the clinical significance of two aspects of the standardization of the 10MWT in mild PD: static vs. dynamic start, and a single vs. repeated trials. Implications for fall prediction were also explored. 151 people with PD (mean age and PD duration, 68 and 4 years, respectively) completed the 10MWT in comfortable gait speed with static and dynamic start (two trials each), and gait speed (m/s) was recorded. Participants then registered all prospective falls for 6 months. Absolute mean differences between outcomes from the various test conditions ranged between 0.016 and 0.040 m/s (effect sizes, 0.06-0.14) with high levels of agreement (intra-class correlation coefficients, 0.932-0.987) and small standard errors of measurement (0.032-0.076 m/s). Receiver operating characteristic curves showed similar discriminate abilities for prediction of future falls across conditions (areas under curves, 0.70-0.73). Cut-off points were estimated at 1.1-1.2 m/s. Different 10MWT standardizations yield very similar results, suggesting that there is no practical need for an acceleration distance or repeated trials when conducting this test in mild PD.
Common Risk Criteria Standards for National Test Ranges
2017-09-01
critical assets. Equipment and facilities that comprise part of an on- or off-base renewable energy system, such as wind turbine generation facilities...to be protected. As an example, for a wind turbine farm, the unit component would be a single wind turbine . A unit component can be considered...functionality of the larger system to which the unit component belongs. For example, a single wind turbine is a unit component of a wind turbine farm. A
Johnson, Jeffrey P.; Villard, Sarah; Kiran, Swathi
2017-01-01
Purpose This study was conducted to investigate the static and dynamic relationships between impairment-level cognitive-linguistic abilities and activity-level functional communication skills in persons with aphasia (PWA). Method In Experiment 1, a battery of standardized assessments was administered to a group of PWA (N = 72) to examine associations between cognitive-linguistic ability and functional communication at a single time point. In Experiment 2, impairment-based treatment was administered to a subset of PWA from Experiment 1 (n = 39) in order to examine associations between change in cognitive-linguistic ability and change in function and associations at a single time point. Results In both experiments, numerous significant associations were found between scores on tests of cognitive-linguistic ability and a test of functional communication at a single time point. In Experiment 2, significant treatment-induced gains were seen on both types of measures in participants with more severe aphasia, yet cognitive-linguistic change scores were not significantly correlated with functional communication change scores. Conclusions At a single time point, cognitive-linguistic and functional communication abilities are associated in PWA. However, although changes on standardized assessments reflecting improvements in both types of skills can occur following an impairment-based therapy, these changes may not be significantly associated with each other. PMID:28196373
NASA Astrophysics Data System (ADS)
Krebs, K.
Testing programs carried out by the European Communities to establish testing techniques and standards for verifying the reliability and integrity of solar cells intended for the marketplace are described. The efforts are being expended to assure quality control and certification for photovoltaic (PV) products manufactured in any of the member nations. The failure rate for PV modules was lowered to 0.5 pct/year by 1981, and single cell failures are projected to be lowered to 0.00001/yr, connectors to 0.001/yr, and batteries to 0.01/yr. Day/night thermal cycling causes the most dominant type of failures, i.e., cracked cells and interconnect defects. Tests have been standardized for inspection, verification, performance, mechanical loading, hail impact, damp heat, high temperature long exposure, hot-spot heating, thermal cycling, and humidity-freezing tolerance.
James W. Evans; David E. Kretschmann; Victoria L. Herian; David W. Green
2001-01-01
ASTM D1990, âEstablishing Allowable Properties for Visually Graded Dimension Lumber from In-Grade Tests of Full-Size Specimens,â is the consensus standard used to make submissions of allowable properties for many U.S., Canadian, and foreign species to the Board of Review of the American Lumber Standards Committee. Recently, it has become apparent how difficult it is to...
Evaluation and Field Assessment of Bifacial Photovoltaic Module Power Rating Methodologies
DOE Office of Scientific and Technical Information (OSTI.GOV)
Deline, Chris; MacAlpine, Sara; Marion, Bill
2016-11-21
1-sun power ratings for bifacial modules are currently undefined. This is partly because there is no standard definition of rear irradiance given 1000 Wm-2 on the front. Using field measurements and simulations, we evaluate multiple deployment scenarios for bifacial modules and provide details on the amount of irradiance that could be expected. A simplified case that represents a single module deployed under conditions consistent with existing 1-sun irradiance standards leads to a bifacial reference condition of 1000 Wm-2 Gfront and 130-140 Wm-2 Grear. For fielded systems of bifacial modules, Grear magnitude and spatial uniformity will be affected by self-shade frommore » adjacent modules, varied ground cover, and ground-clearance height. A standard measurement procedure for bifacial modules is also currently undefined. A proposed international standard is under development, which provides the motivation for this work. Here, we compare outdoor field measurements of bifacial modules with irradiance on both sides with proposed indoor test methods where irradiance is only applied to one side at a time. The indoor method has multiple advantages, including controlled and repeatable irradiance and thermal environment, along with allowing the use of conventional single-sided flash test equipment. The comparison results are promising, showing that the indoor and outdoor methods agree within 1%-2% for multiple rear-irradiance conditions and bifacial module types.« less
Evaluation and Field Assessment of Bifacial Photovoltaic Module Power Rating Methodologies: Preprint
DOE Office of Scientific and Technical Information (OSTI.GOV)
Deline, Chris; MacAlpine, Sara; Marion, Bill
2016-06-16
1-sun power ratings for bifacial modules are currently undefined. This is partly because there is no standard definition of rear irradiance given 1000 Wm-2 on the front. Using field measurements and simulations, we evaluate multiple deployment scenarios for bifacial modules and provide details on the amount of irradiance that could be expected. A simplified case that represents a single module deployed under conditions consistent with existing 1-sun irradiance standards leads to a bifacial reference condition of 1000 Wm-2 Gfront and 130-140 Wm-2 Grear. For fielded systems of bifacial modules, Grear magnitude and spatial uniformity will be affected by self-shade frommore » adjacent modules, varied ground cover, and ground-clearance height. A standard measurement procedure for bifacial modules is also currently undefined. A proposed international standard is under development, which provides the motivation for this work. Here, we compare outdoor field measurements of bifacial modules with irradiance on both sides with proposed indoor test methods where irradiance is only applied to one side at a time. The indoor method has multiple advantages, including controlled and repeatable irradiance and thermal environment, along with allowing the use of conventional single-sided flash test equipment. The comparison results are promising, showing that the indoor and outdoor methods agree within 1%-2% for multiple rear-irradiance conditions and bifacial module types.« less
Unified high-temperature behavior of thin-gauge superalloys
NASA Astrophysics Data System (ADS)
England, Raymond Oliver
This research proposes a methodology for accelerated testing in the area of high-temperature creep and oxidation resistance for thin-gauge superalloy materials. Traditional long-term creep (stress-relaxation) and oxidation tests are completed to establish a baseline. The temperature range used in this study is between 1200 and 1700°F. The alloys investigated are Incoloy MA 956, Waspaloy, Haynes 214, Haynes 242, Haynes 230, and Incoloy 718. The traditional creep test involves loading the specimens to a constant test mandrel radius of curvature, and measuring the retained radius of curvature as a function of time. The accelerated creep test uses a servohydraulic test machine to conduct single specimen, variable strain-rate load relaxation experiments. Standard metallographic evaluations are used to determine extent and morphology of attack in the traditional oxidation tests, while the accelerated oxidation test utilizes thermogravimetric analysis to obtain oxidation rate data. The traditional long-term creep testing indicates that the mechanically-alloyed material Incoloy MA 956 and Haynes alloy 214 may be suitable for long-term, high-temperature (above 1400°F) structural applications. The accelerated creep test produced a continuous linear function of log stress versus strain rate which can be used to calculate creep rate. The long-term and traditional oxidation tests indicate that Al2O3 scale formers such as Incoloy MA 956 and Haynes 214 are much more resistant to high-temperature oxidation than Cr2O3 scale formers such as Waspaloy. Both accelerated tests can be completed within roughly one day, and can evaluate multiple test temperatures using standardized single specimens. These simple experiments can be correlated with traditional long-term tests which require years to complete.
A comparison of the effects of two methods of acclimation of aerobic biodegradability
DOE Office of Scientific and Technical Information (OSTI.GOV)
Watson, H.M.
1993-11-01
The acclimation or adaptation of microorganisms to organic chemicals is an important factor influencing both the rate and the extent of biodegradation. In this study two acclimation procedures were evaluated in terms of their effectiveness in enhancing biodegradation, their relative ease of use in the laboratory, and the implications for biodegradability testing. In the single-flask procedure, microorganisms were acclimated for 2 to 7 d in a single acclimation flask at constant or increasing concentrations of the test chemical without transfer of microorganisms. In the second procedure, the enrichment procedure, microorganisms were acclimated in a series of flasks over a 21-dmore » period by making adaptive transfers to increasing concentrations of the test chemical. Acclimated microorganisms from each procedure were used as the source of inoculum for subsequent biodegradation tests in which carbon dioxide evolution was measured. Six chemicals were tested: quinoline, p-nitrophenol, N-methylaniline, N,N-dimethylaniline, acrylonitrile, and 2,2,4-trimethyl-1,3-pentanediol monoisobutyrate. Microorganisms acclimated in the single-flask procedure were much more effective than those acclimated in the enrichment procedure in degrading the test chemicals. The single-flask procedure is more convenient to use, and it permits monitoring of the time needed for acclimation. The results from these studies have implications for the methodology used in biodegradation test systems and suggest caution before adopting a multiple-flask, enrichment acclimation procedure before the performance of standardized tests for aerobic biodegradability.« less
Evaluation of hyperketonemia risk period and screening protocols for early-lactation dairy cows.
Mahrt, A; Burfeind, O; Heuwieser, W
2015-05-01
The objectives of this study were to describe the onset of hyperketonemia, the number of positive hyperketonemia test results, and the duration of the longest hyperketonemic period during the first 42 d in milk (DIM) in dairy cows. Furthermore, we set out to evaluate test characteristics of single and repeated measurements of β-hydroxybutyric acid (BHBA) during this period to diagnose hyperketonemia. Using an electronic handheld meter, 252 cows from 3 farms were tested twice weekly for hyperketonemia (blood BHBA ≥1.2 mmol/L) during the first 42 DIM, resulting in 12 test results per cow (i.e., in lactation wk 0.5 to 6). Prevalence and incidence of hyperketonemia were calculated for the 12 examination days and the 42-d period, respectively. Test characteristics for the diagnosis of hyperketonemia were calculated for 4 different testing scenarios (testing all cows 1, 2, 3, or 6 times during the first 42 DIM) and 2 different gold-standard definitions (BHBA ≥1.2 mmol/L at least once during the observation period or BHBA ≥1.2 mmol/L at least twice during the observation period). Mean prevalence of hyperketonemia was 11.8%, ranging from 9.6% in lactation wk 0.5 and 2.0 to 14.6% in lactation wk 5.5. In total, 134 cows (53.2%) had at least 1 positive hyperketonemia test result during the whole 42-d period. Of these cows, 46.3% had only 1 positive result. The median first positive hyperketonemia test result was in lactation wk 2.0 [interquartile range (IQR) 1.0-3.5]. Median frequency of positive test results in cows affected by hyperketonemia was 2 positive test results (IQR 1-3). Median duration of the longest hyperketonemic period per cow affected was 1 examination interval (3-4 d; IQR 1-2). Considering a minimum of 1 positive hyperketonemia test result during the first 42 DIM as the gold standard, sensitivity of a single BHBA measurement during this period to diagnose hyperketonemia was 21%. A weekly testing protocol had a sensitivity of 72%. Specificity was 100% in both cases. Considering a minimum of 2 positive hyperketonemia test results as the gold standard, sensitivity and specificity of a single BHBA measurement during the first 42 DIM were 33 and 97%, respectively. A weekly testing protocol provided sensitivity and specificity of 91 and 83%, respectively. We conclude that the risk period for hyperketonemia lasts at least until lactation wk 6, which should be considered when planning hyperketonemia screening programs. Test characteristics of screening protocols depend on testing frequency. Copyright © 2015 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Farnell, D J J; Popat, H; Richmond, S
2016-06-01
Methods used in image processing should reflect any multilevel structures inherent in the image dataset or they run the risk of functioning inadequately. We wish to test the feasibility of multilevel principal components analysis (PCA) to build active shape models (ASMs) for cases relevant to medical and dental imaging. Multilevel PCA was used to carry out model fitting to sets of landmark points and it was compared to the results of "standard" (single-level) PCA. Proof of principle was tested by applying mPCA to model basic peri-oral expressions (happy, neutral, sad) approximated to the junction between the mouth/lips. Monte Carlo simulations were used to create this data which allowed exploration of practical implementation issues such as the number of landmark points, number of images, and number of groups (i.e., "expressions" for this example). To further test the robustness of the method, mPCA was subsequently applied to a dental imaging dataset utilising landmark points (placed by different clinicians) along the boundary of mandibular cortical bone in panoramic radiographs of the face. Changes of expression that varied between groups were modelled correctly at one level of the model and changes in lip width that varied within groups at another for the Monte Carlo dataset. Extreme cases in the test dataset were modelled adequately by mPCA but not by standard PCA. Similarly, variations in the shape of the cortical bone were modelled by one level of mPCA and variations between the experts at another for the panoramic radiographs dataset. Results for mPCA were found to be comparable to those of standard PCA for point-to-point errors via miss-one-out testing for this dataset. These errors reduce with increasing number of eigenvectors/values retained, as expected. We have shown that mPCA can be used in shape models for dental and medical image processing. mPCA was found to provide more control and flexibility when compared to standard "single-level" PCA. Specifically, mPCA is preferable to "standard" PCA when multiple levels occur naturally in the dataset. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Xue, Xiaonan; Kim, Mimi Y; Castle, Philip E; Strickler, Howard D
2014-03-01
Studies to evaluate clinical screening tests often face the problem that the "gold standard" diagnostic approach is costly and/or invasive. It is therefore common to verify only a subset of negative screening tests using the gold standard method. However, undersampling the screen negatives can lead to substantial overestimation of the sensitivity and underestimation of the specificity of the diagnostic test. Our objective was to develop a simple and accurate statistical method to address this "verification bias." We developed a weighted generalized estimating equation approach to estimate, in a single model, the accuracy (eg, sensitivity/specificity) of multiple assays and simultaneously compare results between assays while addressing verification bias. This approach can be implemented using standard statistical software. Simulations were conducted to assess the proposed method. An example is provided using a cervical cancer screening trial that compared the accuracy of human papillomavirus and Pap tests, with histologic data as the gold standard. The proposed approach performed well in estimating and comparing the accuracy of multiple assays in the presence of verification bias. The proposed approach is an easy to apply and accurate method for addressing verification bias in studies of multiple screening methods. Copyright © 2014 Elsevier Inc. All rights reserved.
7 CFR 58.1 - Meaning of words.
Code of Federal Regulations, 2013 CFR
2013-01-01
..., GENERAL SPECIFICATIONS FOR APPROVED PLANTS AND STANDARDS FOR GRADES OF DAIRY PRODUCTS 1 Regulations... official tests in accordance with this part. Approved plant means one or more adjacent buildings, or parts thereof, comprising a single plant at one location in which the facilities and methods of operation...
7 CFR 58.1 - Meaning of words.
Code of Federal Regulations, 2012 CFR
2012-01-01
..., GENERAL SPECIFICATIONS FOR APPROVED PLANTS AND STANDARDS FOR GRADES OF DAIRY PRODUCTS 1 Regulations... official tests in accordance with this part. Approved plant means one or more adjacent buildings, or parts thereof, comprising a single plant at one location in which the facilities and methods of operation...
7 CFR 58.1 - Meaning of words.
Code of Federal Regulations, 2014 CFR
2014-01-01
..., GENERAL SPECIFICATIONS FOR APPROVED PLANTS AND STANDARDS FOR GRADES OF DAIRY PRODUCTS 1 Regulations... official tests in accordance with this part. Approved plant means one or more adjacent buildings, or parts thereof, comprising a single plant at one location in which the facilities and methods of operation...
34 CFR 668.156 - Approved State process.
Code of Federal Regulations, 2010 CFR
2010-07-01
... student's eligibility for Title IV, HEA program funds must apply to the Secretary for approval of that... than a single standardized test; (3) Tutoring in basic verbal and quantitative skills, if appropriate... program completion. (d) A State process must— (1) Monitor on an annual basis each participating...
Statistics Using Just One Formula
ERIC Educational Resources Information Center
Rosenthal, Jeffrey S.
2018-01-01
This article advocates that introductory statistics be taught by basing all calculations on a single simple margin-of-error formula and deriving all of the standard introductory statistical concepts (confidence intervals, significance tests, comparisons of means and proportions, etc) from that one formula. It is argued that this approach will…
Angheben, Andrea; Staffolani, Silvia; Anselmi, Mariella; Tais, Stefano; Degani, Monica; Gobbi, Federico; Buonfrate, Dora; Gobbo, Maria; Bisoffi, Zeno
2017-11-01
We analyzed the accuracy of Chagas Quick Test ® , a rapid diagnostic test, for the diagnosis of chronic Chagas disease through a retrospective study on a cohort of 669 patients consecutively examined at a single reference center in Italy, during a 7-year period. We observed high concordance with serological reference standard but low accuracy for screening purposes (sensitivity/specificity: 82.8%/98.7%) at least in our nonendemic context.
Kekuda, T.R Prashith; Kavya, R; Shrungashree, R.M; Suchitra, S.V
2010-01-01
The present study deals with antimicrobial activity of ayurvedic drugs containing single herb (Amalaki Choorna and Yastimadhu Choorna) and combination of herbs (DN-90 and Asanadi Kwatha Choorna). Disc diffusion method was used to assess antibacterial activity and antifungal activity was tested using Poison food technique. Absence of bacterial growth around the discs impregnated with the aqueous extracts of drugs and reduction of fungal growth in poisoned plates indicated antimicrobial activity. Further, the results of antibacterial activity of Amalaki choorna were comparable with standard drug Streptomycin. Asanadi Kwatha Choorna inhibited bacteria to more extent than Yastimadhu choorna and DN-90. Among fungi tested, more antifungal activity was observed against Mucor sp. The antimicrobial activity of drugs tested could be due to active principles present in them. PMID:22557355
An omnibus test for family-based association studies with multiple SNPs and multiple phenotypes.
Lasky-Su, Jessica; Murphy, Amy; McQueen, Matthew B; Weiss, Scott; Lange, Christoph
2010-06-01
We propose an omnibus family-based association test (MFBAT) that can be applied to multiple markers and multiple phenotypes and that has only one degree of freedom. The proposed test statistic extends current FBAT methodology to incorporate multiple markers as well as multiple phenotypes. Using simulation studies, power estimates for the proposed methodology are compared with the standard methodologies. On the basis of these simulations, we find that MFBAT substantially outperforms other methods, including haplotypic approaches and doing multiple tests with single single-nucleotide polymorphisms (SNPs) and single phenotypes. The practical relevance of the approach is illustrated by an application to asthma in which SNP/phenotype combinations are identified and reach overall significance that would not have been identified using other approaches. This methodology is directly applicable to cases in which there are multiple SNPs, such as candidate gene studies, cases in which there are multiple phenotypes, such as expression data, and cases in which there are multiple phenotypes and genotypes, such as genome-wide association studies that incorporate expression profiles as phenotypes. This program is available in the PBAT analysis package.
Scotter, M J; Castle, L; Roberts, D P T; Macarthur, R; Brereton, P A; Hasnip, S K; Katz, N
2009-05-01
A method for the determination of cyclamate has been developed and single-laboratory validated for a range of foodstuffs including carbonated and fruit-juice drinks, fruit preserves, spreads, and dairy desserts. The method uses the peroxide oxidation of cyclamate to cyclohexylamine followed by derivatization with trinitrobenzenesulfonic acid and analysis by a modified reversed-phase high-performance liquid chromatography-ultraviolet light (HPLC-UV). Cycloheptylamine is used as an internal standard. The limits of detection were in the range 1-20 mg kg(-1) and the analysis was linear up to 1300 mg kg(-1) cyclamic acid in foods and up to 67 mg l(-1) in beverages. Analytical recovery was between 82% and 123%, and results were recovery corrected. Precision was within experimentally predicted levels for all of the matrices tested and Horrat values for the combined standard uncertainty associated with the measurement of cyclamate between 0.4 (water-based drinks) and 1.7 (spreads). The method was used successfully to test three soft drink samples for homogeneity before analytical performance assessment. The method is recommended for use in monitoring compliance and for formal testing by collaborative trial.
Data encryption standard ASIC design and development report.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Robertson, Perry J.; Pierson, Lyndon George; Witzke, Edward L.
2003-10-01
This document describes the design, fabrication, and testing of the SNL Data Encryption Standard (DES) ASIC. This device was fabricated in Sandia's Microelectronics Development Laboratory using 0.6 {micro}m CMOS technology. The SNL DES ASIC was modeled using VHDL, then simulated, and synthesized using Synopsys, Inc. software and finally IC layout was performed using Compass Design Automation's CAE tools. IC testing was performed by Sandia's Microelectronic Validation Department using a HP 82000 computer aided test system. The device is a single integrated circuit, pipelined realization of DES encryption and decryption capable of throughputs greater than 6.5 Gb/s. Several enhancements accommodate ATMmore » or IP network operation and performance scaling. This design is the latest step in the evolution of DES modules.« less
NASA Technical Reports Server (NTRS)
Scheick, Leif
2014-01-01
Single-event-effect test results for hi-rel total-dose-hardened power MOSFETs are presented in this report. The 2N7616 and the 2N7425 from Semicoa and the 2N7480 from International Rectifier were tested to NASA test condition standards and requirements. The 2N7480 performed well and the data agree with the manufacture's data. The 2N7616 and 2N7425 were entry parts from Semicoa using a new device architecture. Unfortunately, the device performed poorly and Semicoa is withdrawing power MOSFETs from it line due to these data. Vertical metal-oxide-semiconductor field-effect transistors (MOSFETs) are the most commonly used power transistor. MOSFETs are typically employed in power supplies and high current switching applications. Due to the inherent high electric fields in the device, power MOSFETs are sensitive to heavy ion irradiation and can fail catastrophically as a result of single-event gate rupture (SEGR) or single-event burnout (SEB). Manufacturers have designed radiation-hardened power MOSFETs for space applications. See [1] through [5] for more information. The objective of this effort was to investigate the SEGR and SEB responses of two power MOSFETs recently produced. These tests will serve as a limited verification of these parts. It is acknowledged that further testing on the respective parts may be needed for some mission profiles.
Laslett, Mark; McDonald, Barry; Tropp, Hans; Aprill, Charles N; Öberg, Birgitta
2005-01-01
Background The tissue origin of low back pain (LBP) or referred lower extremity symptoms (LES) may be identified in about 70% of cases using advanced imaging, discography and facet or sacroiliac joint blocks. These techniques are invasive and availability varies. A clinical examination is non-invasive and widely available but its validity is questioned. Diagnostic studies usually examine single tests in relation to single reference standards, yet in clinical practice, clinicians use multiple tests and select from a range of possible diagnoses. There is a need for studies that evaluate the diagnostic performance of clinical diagnoses against available reference standards. Methods We compared blinded clinical diagnoses with diagnoses based on available reference standards for known causes of LBP or LES such as discography, facet, sacroiliac or hip joint blocks, epidurals injections, advanced imaging studies or any combination of these tests. A prospective, blinded validity design was employed. Physiotherapists examined consecutive patients with chronic lumbopelvic pain and/or referred LES scheduled to receive the reference standard examinations. When diagnoses were in complete agreement regardless of complexity, "exact" agreement was recorded. When the clinical diagnosis was included within the reference standard diagnoses, "clinical agreement" was recorded. The proportional chance criterion (PCC) statistic was used to estimate agreement on multiple diagnostic possibilities because it accounts for the prevalence of individual categories in the sample. The kappa statistic was used to estimate agreement on six pathoanatomic diagnoses. Results In a sample of chronic LBP patients (n = 216) with high levels of disability and distress, 67% received a patho-anatomic diagnosis based on available reference standards, and 10% had more than one tissue origin of pain identified. For 27 diagnostic categories and combinations, chance clinical agreement (PCC) was estimated at 13%. "Exact" agreement between clinical and reference standard diagnoses was 32% and "clinical agreement" 51%. For six pathoanatomic categories (disc, facet joint, sacroiliac joint, hip joint, nerve root and spinal stenosis), PCC was 33% with actual agreement 56%. There was no overlap of 95% confidence intervals on any comparison. Diagnostic agreement on the six most common patho-anatomic categories produced a kappa of 0.31. Conclusion Clinical diagnoses agree with reference standards diagnoses more often than chance. Using available reference standards, most patients can have a tissue source of pain identified. PMID:15943873
Wang, Chun; Zheng, Yi; Chang, Hua-Hua
2014-01-01
With the advent of web-based technology, online testing is becoming a mainstream mode in large-scale educational assessments. Most online tests are administered continuously in a testing window, which may post test security problems because examinees who take the test earlier may share information with those who take the test later. Researchers have proposed various statistical indices to assess the test security, and one most often used index is the average test-overlap rate, which was further generalized to the item pooling index (Chang & Zhang, 2002, 2003). These indices, however, are all defined as the means (that is, the expected proportion of common items among examinees) and they were originally proposed for computerized adaptive testing (CAT). Recently, multistage testing (MST) has become a popular alternative to CAT. The unique features of MST make it important to report not only the mean, but also the standard deviation (SD) of test overlap rate, as we advocate in this paper. The standard deviation of test overlap rate adds important information to the test security profile, because for the same mean, a large SD reflects that certain groups of examinees share more common items than other groups. In this study, we analytically derived the lower bounds of the SD under MST, with the results under CAT as a benchmark. It is shown that when the mean overlap rate is the same between MST and CAT, the SD of test overlap tends to be larger in MST. A simulation study was conducted to provide empirical evidence. We also compared the security of MST under the single-pool versus the multiple-pool designs; both analytical and simulation studies show that the non-overlapping multiple-pool design will slightly increase the security risk.
Foundations of Quantum Mechanics: recent developments at INRIM
DOE Office of Scientific and Technical Information (OSTI.GOV)
Genovese, Marco; Piacentini, Fabrizio
2011-09-23
This paper's purpose is to show some experiments performed in the 'Carlo Novero' labs of the Optics Division of the National Institute of Metrological Research (INRIM, Torino, Italy) in the last years, aiming to discriminate between Standard Quantum Mechanics and some specific, restricted class of Hidden Variable Theories (HVTs).The first experiment, realized in two different configurations, will perform the Alicki - Van Ryn non-classicality test on single particles, in our specific case heralded single photons. The second experiment instead will be on the testing of two restricted Local Realistic Theories (LRTs), properly built to describe polarization entangled photons experiments, whosemore » inequalities are not affected by the detection loophole.« less
Fabrication and evaluation of cold/formed/weldbrazed beta-titanium skin-stiffened compression panels
NASA Technical Reports Server (NTRS)
Royster, D. M.; Bales, T. T.; Davis, R. C.; Wiant, H. R.
1983-01-01
The room temperature and elevated temperature buckling behavior of cold formed beta titanium hat shaped stiffeners joined by weld brazing to alpha-beta titanium skins was determined. A preliminary set of single stiffener compression panels were used to develop a data base for material and panel properties. These panels were tested at room temperature and 316 C (600 F). A final set of multistiffener compression panels were fabricated for room temperature tests by the process developed in making the single stiffener panels. The overall geometrical dimensions for the multistiffener panels were determined by the structural sizing computer code PASCO. The data presented from the panel tests include load shortening curves, local buckling strengths, and failure loads. Experimental buckling loads are compared with the buckling loads predicted by the PASCO code. Material property data obtained from tests of ASTM standard dogbone specimens are also presented.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shibata, K.; Ogata, T.; Nyilas, A.
2006-03-31
Ogata et al. reported in 1996 results of international Round Robin tests on mechanical property measurement of several metals at cryogenic temperatures. Following the report, the standard deviation of Young's modulus of 316L steel is much larger than those of yield and tensile strengths, that is, 4.6 % of the mean value for Young's modulus, while 1.4 % and 1.6 % of the mean values for yield and for tensile strengths, respectively. Therefore, an international Round Robin test on Young's modulus of two austenitic stainless steels at cryogenic temperatures under the participation often institutes from four nations has been initiatedmore » within these two years. As a result, the ratios of standard deviation to the mean values are 4.2 % for 304L and 3.6 % for 316L. Such a drop in the standard deviation is attributable to the decrease in the number of institute owing to the application of single extensometer or direct strain gage technique.« less
NASA Astrophysics Data System (ADS)
Bakale, Raghavendra P.; Naik, Ganesh N.; Machakanur, Shrinath S.; Mangannavar, Chandrashekhar V.; Muchchandi, Iranna S.; Gudasi, Kalagouda B.
2018-02-01
A hydrazone ligand has been synthesized by the condensation of 2-nitrobenzaldehyde and hydralazine, and its Co(II), Ni(II), Cu(II) and Zn(II) complexes have been reported. Structural characterization of the ligand and its metal complexes has been performed by various spectroscopic [IR, NMR, UV-Vis, Mass], thermal and other physicochemical methods. The structure of the ligand and its Ni(II) complex has been characterized by single crystal X-ray diffraction studies. All the synthesized compounds have been screened for in vitro antimicrobial activity. The antibacterial activity is tested against Gram-positive strains Enterococcus faecalis, Streptococcus mutans and Staphylococcus aureus and Gram-negative strains Escherichia coli, Pseudomonas aeruginosa and Klebsiella pneumoniae using ciprofloxacin as the reference standard. Antifungal activity is tested against Candida albicans, Aspergillus fumigatus and Aspergillus niger using ketoconazole as the reference standard. The minimum inhibitory concentration (MIC) was determined for test compounds as well as for reference standard. Ligand, Cu(II) and Zn(II) complexes have shown excellent activity against Candida albicans.
NASA Astrophysics Data System (ADS)
Wang, Qiushi; He, Yuping
2016-01-01
The Society of Automotive Engineers issued a test procedure, SAE-J2179, to determine the rearward amplification (RA) of multi-trailer articulated heavy vehicles (MTAHVs). Built upon the procedure, the International Organization for Standardization released the test manoeuvres, ISO-14791, for evaluating directional performance of MTAHVs. For the RA measures, ISO-14791 recommends two single lane-change manoeuvres: (1) an open-loop procedure with a single sine-wave steering input; and (2) a closed-loop manoeuvre with a single sine-wave lateral acceleration input. For an articulated vehicle with active trailer steering (ATS), the RA measure in lateral acceleration under the open-loop manoeuvre was not in good agreement with that under the closed-loop manoeuvre. This observation motivates the research on the applicability of the two manoeuvres for the RA measures of MTAHVs with ATS. It is reported that transient response under the open-loop manoeuvre often leads to asymmetric curve of tractor lateral acceleration [Winkler CB, Fancher PS, Bareket Z, Bogard S, Johnson G, Karamihas S, Mink C. Heavy vehicle size and weight - test procedures for minimum safety performance standards. Final technical report, NHTSA, US DOT, contract DTNH22-87-D-17174, University of Michigan Transportation Research Institute, Report No. UMTRI-92-13; 1992]. To explore the effect of the transient response, a multiple cycle sine-wave steering input (MCSSI) manoeuvre is proposed. Simulation demonstrates that the steady-state RA measures of an MTAHV with and without ATS under the MCSSI manoeuvre are in excellent agreement with those under the closed-loop manoeuvre. It is indicated that between the two manoeuvres by ISO-14791, the closed-loop manoeuvre is more applicable for determining the RA measures of MTAHVs with ATS.
NASA Astrophysics Data System (ADS)
Li, Xiaodan; Huang, Shuangjun; Xu, Liang; Hui, Li; Zhou, Song
2017-12-01
The bolt structural properties of selective laser melted (SLM) samples produced from TC4 powder metal has been investigated. Two different connection molds relative to single lap joint and bilateral lap joint as well as two different state of surface quality were considered. Samples and test procedures were designed in accordance with HB 5143 and HB 5287 standard. The results show that there is a strong influence of connection molds on the dynamic behavior of SLM produced TC4. The mechanical properties of bilateral lap joint are better than those of the single lap joint. Meanwhile the fatigue performance of the bilateral lap joint is much stronger than that of the single lap joint which it is a symmetrical structure of the two-shear test on both sides of the force evenly, while the single lap joint is a single shear sample of the uneven force. There are two kinds of fracture form most of which are broken in the first row of screw and a small part in the middle of the connecting plate.
Epilogue: Reading Comprehension Is Not a Single Ability-Implications for Assessment and Instruction.
Kamhi, Alan G; Catts, Hugh W
2017-04-20
In this epilogue, we review the 4 response articles and highlight the implications of a multidimensional view of reading for the assessment and instruction of reading comprehension. We reiterate the problems with standardized tests of reading comprehension and discuss the advantages and disadvantages of recently developed authentic tests of reading comprehension. In the "Instruction" section, we review the benefits and limitations of strategy instruction and highlight suggestions from the response articles to improve content and language knowledge. We argue that the only compelling reason to administer a standardized test of reading comprehension is when these tests are necessary to qualify students for special education services. Instruction should be focused on content knowledge, language knowledge, and specific task and learning requirements. This instruction may entail the use of comprehension strategies, particularly those that are specific to the task and focus on integrating new knowledge with prior knowledge.
Geue, Lutz; Stieber, Bettina; Monecke, Stefan; Engelmann, Ines; Gunzer, Florian; Slickers, Peter; Braun, Sascha D; Ehricht, Ralf
2014-08-01
In this study, we developed a new rapid, economic, and automated microarray-based genotyping test for the standardized subtyping of Shiga toxins 1 and 2 of Escherichia coli. The microarrays from Alere Technologies can be used in two different formats, the ArrayTube and the ArrayStrip (which enables high-throughput testing in a 96-well format). One microarray chip harbors all the gene sequences necessary to distinguish between all Stx subtypes, facilitating the identification of single and multiple subtypes within a single isolate in one experiment. Specific software was developed to automatically analyze all data obtained from the microarray. The assay was validated with 21 Shiga toxin-producing E. coli (STEC) reference strains that were previously tested by the complete set of conventional subtyping PCRs. The microarray results showed 100% concordance with the PCR results. Essentially identical results were detected when the standard DNA extraction method was replaced by a time-saving heat lysis protocol. For further validation of the microarray, we identified the Stx subtypes or combinations of the subtypes in 446 STEC field isolates of human and animal origin. In summary, this oligonucleotide array represents an excellent diagnostic tool that provides some advantages over standard PCR-based subtyping. The number of the spotted probes on the microarrays can be increased by additional probes, such as for novel alleles, species markers, or resistance genes, should the need arise. Copyright © 2014, American Society for Microbiology. All Rights Reserved.
Hybrid photodetector for single-molecule spectroscopy and microscopy
Michalet, X.; Cheng, Adrian; Antelman, Joshua; Suyama, Motohiro; Arisaka, Katsushi; Weiss, Shimon
2011-01-01
We report benchmark tests of a new single-photon counting detector based on a GaAsP photocathode and an electron-bombarded avalanche photodiode developed by Hamamatsu Photonics. We compare its performance with those of standard Geiger-mode avalanche photodiodes. We show its advantages for FCS due to the absence of after-pulsing and for fluorescence lifetime measurements due to its excellent time resolution. Its large sensitive area also greatly simplifies setup alignment. Its spectral sensitivity being similar to that of recently introduced CMOS SPADs, this new detector could become a valuable tool for single-molecule fluorescence measurements, as well as for many other applications. PMID:21822361
Janssen, T J; Guelen, P J; Vree, T B; Botterblom, M H; Valducci, R
1988-01-01
The bioavailability of a new ambroxol sustained release preparation (75 mg) based on a dialyzing membrane for controlled release was studied in healthy volunteers after single and multiple oral dose in comparison with a standard sustained release formulation in a cross-over study under carefully controlled conditions. Plasma concentrations of ambroxol were measured by means of a HPLC method. Based on AUC data both preparations are found to be bioequivalent, but show different plasma concentration profiles. The test preparation showed a more pronounced sustained release profile than the reference preparation (single dose) resulting in significantly higher steady state plasma levels.
Heavy Ion Irradiation Fluence Dependence for Single-Event Upsets of NAND Flash Memory
NASA Technical Reports Server (NTRS)
Chen, Dakai; Wilcox, Edward; Ladbury, Raymond; Kim, Hak; Phan, Anthony; Seidleck, Christina; LaBel, Kenneth
2016-01-01
We investigated the single-event effect (SEE) susceptibility of the Micron 16 nm NAND flash, and found the single-event upset (SEU) cross section varied inversely with fluence. The SEU cross section decreased with increasing fluence. We attribute the effect to the variable upset sensitivities of the memory cells. The current test standards and procedures assume that SEU follow a Poisson process and do not take into account the variability in the error rate with fluence. Therefore, heavy ion irradiation of devices with variable upset sensitivity distribution using typical fluence levels may underestimate the cross section and on-orbit event rate.
Remittance spectroscopy of human skin in vivo.
Geyer, A; Vilser, W; Karte, K; Wollina, U
1996-08-01
The skin is an easily accessible organ on which non-invasive examination methods can be applied. Recently spectroscopic methods have been introduced in characterization of skin under physiological and pathological conditions. To examine remittance spectroscopic qualities of human skin in vivo and to clarify the influence of selected test conditions, a single-beam spectrometer MCS 410 (Carl Zeiss, Jena, Germany) has been used. Remittance spectra readings were performed in 35 volunteers. Wavelength ranged from 362 nm to 780 nm. Individual remittance values and their standard deviations were obtained from 20 readings under standardized test conditions. The effect of pressure, rubbing, cooling, washing, greasing and degreasing on average remittance values was investigated. Statistical analysis was done with paired Student's f-test and Fisher's test. Pressure increased remittance values over a wide range of wavelength, peaking at 518 nm. Greasing and degreasing modified spectral remittance of shorter wavelength peaking around 362 nm. Rubbing and cooling did not induce significant variations of spectral remittance of skin. Spectral remittance provides an individual profile in human skin, which may be influenced by pressure and greasing/ degreasing. To establish standardized test conditions with a narrow range of intra-individual variation these items have to be kept constant.
Monitoring of anticoagulant therapy in heart disease: considerations for the current assays.
Boroumand, Mohammadali; Goodarzynejad, Hamidreza
2010-01-01
Clinicians should be aware of new developments to familiarize themselves with pharmacokinetic and pharmacodynamic characteristics of new anticoagulant agents to appropriately and safely use them. For the moment, cardiologists and other clinicians also require to master currently available drugs, realizing the mechanism of action, side effects, and laboratory monitoring to measure their anticoagulant effects. Warfarin and heparin have narrow therapeutic window with high inter- and intra-patient variability, thereby the use of either drug needs careful laboratory monitoring and dose adjustment to ensure proper antithrombotic protection while minimizing the bleeding risk. The prothrombin time (PT) and the activated partial thromboplastin time (aPTT) are laboratory tests commonly used to monitor warfarin and heparin, respectively. These two tests depend highly on the combination of reagent and instrument utilized. Results for a single specimen tested in different laboratories are variable; this is mostly attributable to the specific reagents and to a much lesser degree to the instrument used. The PT stands alone as the single coagulation test that has undergone the most extensive attempt at assay standardization. The international normalized ratio (INR) was introduced to "normalize" all PT reagents to a World Health Organization (WHO) reference thromboplastin preparation standard, such that a PT measured anywhere in the world would result in an INR value similar to that which would have been achieved had the WHO reference thromboplastin been utilized. However, INRs are reproducible between laboratories for only those patients who are stably anticoagulated with vitamin K antagonists (VKAs) (i.e., at least 6 weeks of VKA therapy), and are not reliable or reproducible between laboratories for patients for whom VKA therapy has recently been started or any other clinical conditions associated with a prolonged PT such as liver disease, disseminated intravascular coagulation, and congenital factor deficiencies. In contrast to marked progress in the standardization of PT reagents for INR reporting, no standardization system has been globally adopted for standardization of PTT reagents. Recently College of American Pathologists recommend that individual laboratories establish their own therapeutic range by using aPTT values calibrated against accepted therapeutic unfractionated heparin (UFH) levels calibrated against accepted therapeutic UFH levels performing anti-Xa test (which is the most accurate assay for monitoring UFH therapy).Herein, we review recent data on the monitoring of conventional anticoagulant agents. Marked interlaboratory variability still exists for PT, INR, and PTT tests. Further research should be focused on improving the standardization and calibration of these assays.
Single-gender mathematics and science classes and the effects on urban middle school boys and girls
NASA Astrophysics Data System (ADS)
Sudler, Dawn M.
This study compared the differences in the Criterion-Referenced Competency Test (CRCT) mathematics and science achievement scores of boys and girls in Grade 7 at two urban middle schools. The data allowed the researcher to determine to what degree boys and girls in Grade 7 differ in their mathematics and science achievements within a single-gender environment versus a coeducational learning environment. The study compared any differences between boys and girls in Grade 7 within a single-gender environment in the subjects of mathematics and science, as measured by the CRCT assessments. The study also compared differences between boys and girls in Grade 7 within a coeducational environment in the subjects of mathematics and science, as measured by the CRCT assessments. Two middle schools were used within the study. One middle school was identified as a single-gender school (Middle School A); the other was identified as a coeducational school (Middle School B). This quantitative study applied the use of a descriptive research design. In addition, CRCT scores for the subjects of mathematics and science were taken during the spring of 2008 from both middle schools. Data were measured using descriptive statistics and independent t test calculations. The frequency statistics proceeded to compare each sample performance levels. The data were described in means, standard deviations, standard error means, frequency, and percentages. This method provided an excellent description of a sample scored on the spring 2008 CRCT mathematics and science assessments.
Sangster, William; Messaris, Evangelos; Berg, Arthur S.; Stewart, David B.
2015-01-01
BACKGROUND Compared to standard laparoscopy, single-site laparoscopic colorectal surgerymay potentially offer advantages by creating fewer surgical incisions and providing a multi-functional trocar. Previous comparisons, however, have been limited by small sample sizes and selection bias. OBJECTIVE To compare 60-day outcomes between standard laparoscopic and single-site laparoscopic colorectal surgery patients undergoing elective and urgent surgeries. DESIGN This was an unselected retrospective cohort study comparing patients who underwent elective and unplanned standard laparoscopic or single-site laparoscopic colorectal resections for benign and malignant disease between 2008 and 2014. Outcomes were compared using univariate analyses. SETTING This study was conducted at a single institution. PATIENTS A total of 626 consecutive patients undergoing laparoscopic colorectal surgery were included. MAIN OUTCOME MEASURES Morbidity and mortality within 60 postoperative days. RESULTS 318 (51%) and 308 (49%) patients underwent standard laparoscopic and single-site laparoscopic procedures, respectively. No significant difference was noted in mean operative time (Standard laparoscopy 182.1 ± 81.3 vs. Single-site laparoscopy 177±86.5, p=0.30) and postoperative length of stay (Standard laparoscopy 4.8±3.4 vs. Single-site laparoscopy 5.5 ± 6.9, p=0.14). Conversions to laparotomy and 60-day readmissions were also similar for both cohorts across all procedures performed. A significant difference was identified in the number of patients who developed postoperative complications (Standard laparoscopy 19.2% vs. Single-site laparoscopy 10.7%, p=0.004), especially with respect to surgical-site infections (Standard laparoscopy 11.3% vs. Single-site laparoscopy 5.8%, p=0.02). LIMITATIONS This was a retrospective, single institution study. CONCLUSIONS Single-site laparoscopic colorectal surgery demonstrates similar results to standard laparoscopic colorectal surgery in regards to operative time, length of stay and readmissions. Single-site laparoscopic colorectal surgery may provide advantages in limiting the development of certain complications such as superficial surgical-site infections. PMID:26252848
Diffusion models of the flanker task: Discrete versus gradual attentional selection
White, Corey N.; Ratcliff, Roger; Starns, Jeffrey S.
2011-01-01
The present study tested diffusion models of processing in the flanker task, in which participants identify a target that is flanked by items that indicate the same (congruent) or opposite response (incongruent). Single- and dual-process flanker models were implemented in a diffusion-model framework and tested against data from experiments that manipulated response bias, speed/accuracy tradeoffs, attentional focus, and stimulus configuration. There was strong mimcry among the models, and each captured the main trends in the data for the standard conditions. However, when more complex conditions were used, a single-process spotlight model captured qualitative and quantitative patterns that the dual-process models could not. Since the single-process model provided the best balance of fit quality and parsimony, the results indicate that processing in the simple versions of the flanker task is better described by gradual rather than discrete narrowing of attention. PMID:21964663
Sudarski, Sonja; Henzler, Thomas; Haubenreisser, Holger; Dösch, Christina; Zenge, Michael O; Schmidt, Michaela; Nadar, Mariappan S; Borggrefe, Martin; Schoenberg, Stefan O; Papavassiliu, Theano
2017-01-01
Purpose To prospectively evaluate the accuracy of left ventricle (LV) analysis with a two-dimensional real-time cine true fast imaging with steady-state precession (trueFISP) magnetic resonance (MR) imaging sequence featuring sparse data sampling with iterative reconstruction (SSIR) performed with and without breath-hold (BH) commands at 3.0 T. Materials and Methods Ten control subjects (mean age, 35 years; range, 25-56 years) and 60 patients scheduled to undergo a routine cardiac examination that included LV analysis (mean age, 58 years; range, 20-86 years) underwent a fully sampled segmented multiple BH cine sequence (standard of reference) and a prototype undersampled SSIR sequence performed during a single BH and during free breathing (non-BH imaging). Quantitative analysis of LV function and mass was performed. Linear regression, Bland-Altman analysis, and paired t testing were performed. Results Similar to the results in control subjects, analysis of the 60 patients showed excellent correlation with the standard of reference for single-BH SSIR (r = 0.93-0.99) and non-BH SSIR (r = 0.92-0.98) for LV ejection fraction (EF), volume, and mass (P < .0001 for all). Irrespective of breath holding, LV end-diastolic mass was overestimated with SSIR (standard of reference: 163.9 g ± 58.9, single-BH SSIR: 178.5 g ± 62.0 [P < .0001], non-BH SSIR: 175.3 g ± 63.7 [P < .0001]); the other parameters were not significantly different (EF: 49.3% ± 11.9 with standard of reference, 48.8% ± 11.8 with single-BH SSIR, 48.8% ± 11 with non-BH SSIR; P = .03 and P = .12, respectively). Bland-Altman analysis showed similar measurement errors for single-BH SSIR and non-BH SSIR when compared with standard of reference measurements for EF, volume, and mass. Conclusion Assessment of LV function with SSIR at 3.0 T is noninferior to the standard of reference irrespective of BH commands. LV mass, however, is overestimated with SSIR. © RSNA, 2016 Online supplemental material is available for this article.
Persistence of Immunity Acquired after a Single Dose of Rubella Vaccine in Japan.
Okafuji, Takao; Okafuji, Teruo; Nakayama, Tetsuo
2016-05-20
To date, Takahashi, Matsuura, and TO-336 strains of live-attenuated rubella vaccine have been used in Japan. Japan implemented a single-dose rubella vaccination program until 2006. However, few reports are available on the persistence of immunity after this vaccination program. We collected 276 serum samples from January 2009 to December 2011 at Okafuji Pediatric Clinic and assessed the immune status of these samples against rubella virus during 1-10 years after vaccination with a single dose of Takahashi rubella vaccine. Regional outbreak of rubella did not occur during 1999-2011. The collected serum samples were tested for antibodies against the rubella virus by performing a standard hemagglutination inhibition (HAI) test. Our results showed that all the tested serum samples contained antibodies against the rubella virus 10 years after the vaccination. Geometric mean titer of HAI antibodies was 1:180 and decreased to 1:68 at 10 years after the vaccination. The levels of HAI antibodies decreased logarithmically with time after the vaccination. In conclusion, vaccine-acquired immunity after vaccination with a single dose of live-attenuated Takahashi rubella vaccine was retained for at least 10 years when rubella was under regional control.
Sinha, Pallavi; Gupta, Anamika; Prakash, Pradyot; Anupurba, Shampa; Tripathi, Rajneesh; Srivastava, G N
2016-03-12
Control of the global burden of tuberculosis is obstructed due to lack of simple, rapid and cost effective diagnostic techniques that can be used in resource poor-settings. To facilitate the early diagnosis of TB directly from clinical specimens, we have standardized and validated the use of nested multiplex PCR, targeting gene fragments IS6110, MTP40 and 32kD α-antigen encoding genes specific for Mycobacterium tuberculosis complex and non-tubercular mycobacteria (NTM), in comparison to smear microscopy, solid culture and single step multiplex PCR. The results were evaluated in comparison to a composite reference standard (CRS) comprising of microbiological results (smear and culture), clinical, radiological and cytopathological findings, clinical treatment and response to anti-tubercular therapy. The nested multiplex PCR (nMPCR) assay was evaluated to test its utility in 600 (535 pulmonary and 65 extra-pulmonary specimens) clinically suspected TB cases. All specimens were processed for smear, culture, single step multiplex PCR and nested multiplex PCR testing. Out of 535 screened pulmonary and 65 extra-pulmonary specimens, 329 (61.5%) and 19 (29.2%) cases were culture positive for M. tuberculosis. Based on CRS, 450 patients had "clinical TB" (definitive-TB, probable-TB and possible-TB). Remaining 150 were confirmed "non-TB" cases. For culture, the sensitivity was low, 79.3% for pulmonary and 54.3% for extra-pulmonary cases. The sensitivity and specificity results for nMPCR test were evaluated taken composite reference standard as a gold standard. The sensitivity of the nMPCR assay was 97.1% for pulmonary and 91.4% for extra-pulmonary TB cases with specificity of 100% and 93.3% respectively. Nested multiplex PCR using three gene primers is a rapid, reliable and highly sensitive and specific diagnostic technique for the detection and differentiation of M. tuberculosis complex from NTM genome and will be useful in diagnosing paucibacillary samples. Nested multiplex PCR assay was found to be better than single step multiplex PCR for assessing the diagnosis of TB.
Ardui, Simon; Ameur, Adam; Vermeesch, Joris R; Hestand, Matthew S
2018-01-01
Abstract Short read massive parallel sequencing has emerged as a standard diagnostic tool in the medical setting. However, short read technologies have inherent limitations such as GC bias, difficulties mapping to repetitive elements, trouble discriminating paralogous sequences, and difficulties in phasing alleles. Long read single molecule sequencers resolve these obstacles. Moreover, they offer higher consensus accuracies and can detect epigenetic modifications from native DNA. The first commercially available long read single molecule platform was the RS system based on PacBio's single molecule real-time (SMRT) sequencing technology, which has since evolved into their RSII and Sequel systems. Here we capsulize how SMRT sequencing is revolutionizing constitutional, reproductive, cancer, microbial and viral genetic testing. PMID:29401301
The Weibull probabilities analysis on the single kenaf fiber
NASA Astrophysics Data System (ADS)
Ibrahim, I.; Sarip, S.; Bani, N. A.; Ibrahim, M. H.; Hassan, M. Z.
2018-05-01
Kenaf fiber has a great potential to be replaced with the synthetic composite due to their advantages such as environmentally friendly and outstanding performance. However, the main issue of this natural fiber that to be used in structural composite is inconsistency of their mechanical properties. Here, the influence of the gage length on the mechanical properties of single kenaf fiber was evaluated. This fiber was tested using the Universal testing machine at a loading rate of 1mm per min following ASTM D3822 standard. In this study, the different length of treated fiber including 20, 30 and 40mm were being tested. Following, Weibull probabilities analysis was used to characterize the tensile strength and Young modulus of kenaf fiber. The predicted average tensile strength from this approach is in good agreement with experimental results for the obtained parameter.
Wang, Rong; Xu, Xin
2015-12-01
To compare the effect of 2 methods of occlusion adjustment on occlusal balance and muscles of mastication in patients with dental implant restoration. Twenty patients, each with a single edentulous posterior dentition with no distal dentition were selected, and divided into 2 groups. Patients in group A underwent original occlusion adjustment method and patients in group B underwent occlusal plane reduction technique. Ankylos implants were implanted in the edentulous space in each patient and restored with fixed prosthodontics single unit crown. Occlusion was adjusted in each restoration accordingly. Electromyograms were conducted to determine the effect of adjustment methods on occlusion and muscles of mastication 3 months and 6 months after initial restoration and adjustment. Data was collected and measurements for balanced occlusal measuring standards were obtained, including central occlusion force (COF), asymmetry index of molar occlusal force(AMOF). Balanced muscles of mastication measuring standards were also obtained including measurements from electromyogram for the muscles of mastication and the anterior bundle of the temporalis muscle at the mandibular rest position, average electromyogram measurements of the anterior bundle of the temporalis muscle at the intercuspal position(ICP), Astot, masseter muscle asymmetry index, and anterior temporalis asymmetry index (ASTA). Statistical analysis was performed using Student 's t test with SPSS 18.0 software package. Three months after occlusion adjustment, parameters of the original occlusion adjustment method were significantly different between group A and group B in balanced occlusal measuring standards and balanced muscles of mastication measuring standards. Six months after occlusion adjustment, parameters of the original occlusion adjustment methods were significantly different between group A and group B in balanced muscles of mastication measuring standards, but was no significant difference in balanced occlusal measuring standards. Using occlusion plane reduction adjustment technique, it is possible to obtain occlusion index and muscles of mastication's electromyogram index similar to the opposite side's natural dentition in patients with single unit fix prosthodontics crown and single posterior edentulous dentition without distal dentitions.
NASA Astrophysics Data System (ADS)
Salyer, Terry
2017-06-01
For the bulk of detonation performance experiments, a fairly basic set of diagnostic techniques has evolved as the standard for acquiring the necessary measurements. Gold standard techniques such as pin switches and streak cameras still produce the high-quality data required, yet much room remains for improvement with regard to ease of use, cost of fielding, breadth of data, and diagnostic versatility. Over the past several years, an alternate set of diagnostics has been under development to replace many of these traditional techniques. Pulse Correlation Reflectometry (PCR) is a capable substitute for pin switches with the advantage of obtaining orders of magnitude more data at a small fraction of the cost and fielding time. Spectrally Encoded Imaging (SEI) can replace most applications of streak camera with the advantage of imaging surfaces through a single optical fiber that are otherwise optically inaccessible. Such diagnostics advance the measurement state of the art, but even further improvements may come through revamping the standardized tests themselves such as the copper cylinder expansion test. At the core of this modernization, the aforementioned diagnostics play a significant role in revamping and improving the standard test suite for the present era. This research was performed under the auspices of the United States Department of Energy.
Wojciulik, E; Rorden, C; Clarke, K; Husain, M; Driver, J
2004-09-01
Visual neglect is a relatively common deficit after brain damage, particularly strokes. Cancellation tests provide standard clinical measures of neglect severity and deficits in daily life. A recent single-case study introduced a new variation on standard cancellation. Instead of making a visible mark on each target found, the patient made invisible marks (recorded with carbon paper underneath, for later scoring). Such invisible cancellation was found to reveal more neglect than cancellation with visible marks. Here we test the generality of this. Twenty three successive cases with suspected neglect each performed cancellation with visible or invisible marks. Neglect of contralesional targets was more pronounced with invisible marks. Indeed, about half of the patients only showed neglect in this version. For cases showing more neglect with invisible marks, stronger neglect of contralesional targets correlated with more revisits to ipsilesional targets for making additional invisible marks upon them. These results indicate that cancellation with invisible marks can reveal more neglect than standard cancellation with visible marks, while still providing a practical bedside test. Our observations may be consistent with recent proposals that demands on spatial working memory (required to keep track of previously found items only when marked invisibly) can exacerbate spatial neglect.
Research of Medical Expenditure among Inpatients with Unstable Angina Pectoris in a Single Center
Wu, Suo-Wei; Pan, Qi; Chen, Tong; Wei, Liang-Yu; Xuan, Yong; Wang, Qin; Li, Chao; Song, Jing-Chen
2017-01-01
Background: With the rising incidence as well as the medical expenditure among patients with unstable angina pectoris, the research aimed to investigate the inpatient medical expenditure through the combination of diagnosis-related groups (DRGs) among patients with unstable angina pectoris in a Grade A tertiary hospital to conduct the referential standards of medical costs for the diagnosis. Methods: Single-factor analysis and multiple linear stepwise regression method were used to investigate 3933 cases between 2014 and 2016 in Beijing Hospital (China) whose main diagnosis was defined as unstable angina pectoris to determine the main factors influencing the inpatient medical expenditure, and decision tree method was adopted to establish the model of DRGs grouping combinations. Results: The major influential factors of inpatient medical expenditure included age, operative method, therapeutic effects as well as comorbidity and complications (CCs) of the disease, and the 3933 cases were divided into ten DRGs by four factors: age, CCs, therapeutic effects, and the type of surgery with corresponding inpatient medical expenditure standards setup. Data of nonparametric test on medical costs among different groups were all significant (P < 0.001, by Kruskal-Wallis test), with R2 = 0.53 and coefficient of variation (CV) = 0.524. Conclusions: The classification of DRGs by adopting the type of surgery as the main branch node to develop cost control standards in inpatient treatment of unstable angina pectoris is conducive in standardizing the diagnosis and treatment behaviors of the hospital and reducing economic burdens among patients. PMID:28639566
Research of Medical Expenditure among Inpatients with Unstable Angina Pectoris in a Single Center.
Wu, Suo-Wei; Pan, Qi; Chen, Tong; Wei, Liang-Yu; Xuan, Yong; Wang, Qin; Li, Chao; Song, Jing-Chen
2017-07-05
With the rising incidence as well as the medical expenditure among patients with unstable angina pectoris, the research aimed to investigate the inpatient medical expenditure through the combination of diagnosis-related groups (DRGs) among patients with unstable angina pectoris in a Grade A tertiary hospital to conduct the referential standards of medical costs for the diagnosis. Single-factor analysis and multiple linear stepwise regression method were used to investigate 3933 cases between 2014 and 2016 in Beijing Hospital (China) whose main diagnosis was defined as unstable angina pectoris to determine the main factors influencing the inpatient medical expenditure, and decision tree method was adopted to establish the model of DRGs grouping combinations. The major influential factors of inpatient medical expenditure included age, operative method, therapeutic effects as well as comorbidity and complications (CCs) of the disease, and the 3933 cases were divided into ten DRGs by four factors: age, CCs, therapeutic effects, and the type of surgery with corresponding inpatient medical expenditure standards setup. Data of nonparametric test on medical costs among different groups were all significant (P < 0.001, by Kruskal-Wallis test), with R2 = 0.53 and coefficient of variation (CV) = 0.524. The classification of DRGs by adopting the type of surgery as the main branch node to develop cost control standards in inpatient treatment of unstable angina pectoris is conducive in standardizing the diagnosis and treatment behaviors of the hospital and reducing economic burdens among patients.
Determination of Single-Kidney Glomerular Filtration Rate in Human Subjects by Using CT
Kwon, Soon Hyo; Saad, Ahmed; Herrmann, Sandra M.; Textor, Stephen C.
2015-01-01
Purpose To test the hypothesis that computed tomography (CT)–derived measurements of single-kidney glomerular filtration rate (GFR) obtained in human subjects with 64-section CT agree with those obtained with iothalamate clearance, a rigorous reference standard. Materials and Methods The institutional review board approved this HIPAA-compliant study, and written informed consent was obtained. Ninety-six patients (age range, 51–73 years; 46 men, 50 women) with essential (n = 56) or renovascular (n = 40) hypertension were prospectively studied in controlled conditions (involving sodium intake and renin-angiotensin blockade). Single-kidney perfusion, volume, and GFR were measured by using multidetector CT time-attenuation curves and were compared with GFR measured by using iothalamate clearance, as assigned to the right and left kidney according to relative volumes. The reproducibility of CT GFR over a 3-month period (n = 21) was assessed in patients with renal artery stenosis who were undergoing stable medical treatment. Statistical analysis included the t test, Wilcoxon signed rank test, linear regression, and Bland-Altman analysis. Results CT GFR values were similar to those of iothalamate clearance (mean ± standard deviation, 38.2 mL/min ± 18 vs 41.6 mL/min ± 17; P = .062). Stenotic kidney CT GFR in patients with renal artery stenosis was lower than contralateral kidney GFR or essential hypertension single-kidney GFR (mean, 23.1 mL/min ± 13 vs 36.9 mL/min ± 17 [P = .0008] and 45.2 mL/min ± 16 [P = .019], respectively), as was iothalamate clearance (mean, 26.9 mL/min ± 14 vs 38.5 mL/min ± 15 [P = .0004] and 49.0 mL/min ± 14 [P = .001], respectively). CT GFR correlated well with iothalamate GFR (linear regression, CT GFR = 0.88*iothalamate GFR, r2 = 0.89, P < .0001), and Bland-Altman analysis was used to confirm the agreement. CT GFR was also moderately reproducible in medically treated patients with renal artery stenosis (concordance coefficient correlation, 0.835) but was unaffected by revascularization (mean, 25.3 mL/min ± 15.2 vs 30.3 mL/min ± 18.5; P = .097). Conclusion CT assessments of single-kidney GFR are reproducible and agree well with a reference standard. CT can be useful to obtain minimally invasive estimates of bilateral single-kidney function in human subjects. © RSNA, 2015 PMID:25848903
Huang, Xiaoyan; Zhou, Yujie; Liu, Cui; Zhang, Ruilong; Zhang, Liying; Du, Shuhu; Liu, Bianhua; Han, Ming-Yong; Zhang, Zhongping
2016-12-15
Fluorescent test papers are promising for the wide applications in the assays of diagnosis, environments and foods, but unlike classical dye-absorption-based pH test paper, they are usually limited in the qualitative yes/no type of detection by fluorescent brightness, and the colorimetry-based quantification remains a challenging task. Here, we report a single dual-emissive nanofluorophore probe to achieve the consecutive color variations from blue to red for the quantification of blood glucose on its as-prepared test papers. Red quantum dots were embedded into silica nanoparticles as a stable internal standard emission, and blue carbon dots (CDs) were further covalently linked onto the surface of silica, in which the ratiometric fluorescence intensity of blue to red is controlled at 5:1. While the oxidation of glucose induced the formation of Fe(3+) ions, the blue emission of CDs was thus quenched by the electron transfer from CDs to Fe(3+), displaying a serial of consecutive color variations from blue to red with the dosage of glucose. The high-quality test papers printed by the probe ink exhibited a dosage-sensitive allochromatic capability with the clear differentiations of ~5, 7, 9, 11mM glucose in human serum (normal: 3-8mM). The blood glucose determined by the test paper was almost in accordance with that measured by a standard glucometer. The method reported here opens a window to the wide applications of fluorescent test paper in biological assays. Copyright © 2016 Elsevier B.V. All rights reserved.
Oláh, Viktor; Hepp, Anna; Mészáros, Ilona
2016-05-01
In this study germination of Spirodela polyrhiza (L.) Schleiden (giant duckweed) turions was assessed under cadmium exposure to test applicability of a novel turion-based ecotoxicology method. Floating success of germinating turions, protrusion of the first and subsequent fronds as test endpoints were investigated and compared to results of standard duckweed growth inhibition tests with fronds of the same species. Our results indicate that turions can be used to characterize effects of toxic substances. Initial phase of turion germination (floating up and appearance of the first frond) was less sensitive to Cd treatments than the subsequent frond production. The calculated effective concentrations for growth rates in turion and normal frond tests were similar. Single frond area produced by germinating turions proved to be the most sensitive test endpoint. Single frond area and colony disintegration as additionally measured parameters in normal frond cultures also changed due to Cd treatments but the sensitivity of these parameters was lower than that of growth rates.
Fabrication and testing of silver-hydrogen cells
NASA Technical Reports Server (NTRS)
Debicarri, D. J.; Charkey, A.
1978-01-01
Silver electrodes containing various additives were fabricated and tested in single electrode cells in order to improve the electrochemical utilization of sintered silver cathodes in Ag-H2 aerospace batteries. A standard stack arrangement was used which featured a NASA-developed organic-inorganic separator. All cells were cycled in a regime designed to remove 75% of the cells nominal capacity based on 3.3 gms/AHr Ag utilization. In cases where performance degradation was observed, the main feature mode appeared to be corrosion of either the expanded silver current collector or the connection between the silver electrode and the electrode tab. Promising silver electrodes from single electrode studies were used in the construction of 35 AHr Ag-H2 cells. Two such cells were constructed and installed in heavy walled pressure vessels for testing. Based on the data obtained from all cells tested during the program, four lightweight 35 AHr cells were fabricated. During acceptance testing these cells yielded an average gravimetric energy density of 30 WHr/1b.
Aldrich, Gregory C.; Koppel, Kadri
2015-01-01
Simple Summary Palatability of pet foods is typically measured using a single-bowl or a two-bowl test. While these tests give a general understanding of the liking or preference of one food over another, opportunities exist for further method development. Abstract The pet food industry continues to grow steadily as a result of new innovative products. Quality control and product development tests for pet foods are typically conducted through palatability testing with dogs and cats. Palatability is the measure of intake of a food that indicates acceptance or the measure of preference of one food over another. Pet food palatability is most commonly measured using a single-bowl or a two-bowl assay. While these tests answer some questions about the animals’ perception of the food, there are many limitations as well. This review addresses some of these limitations and indicates opportunities for future research. PMID:26479136
Eigbefoh, J O; Isabu, P; Okpere, E; Abebe, J
2008-07-01
Untreated urinary tract infection can have devastating maternal and neonatal effects. Thus, routine screening for bacteriuria is advocated. This study was designed to evaluate the diagnostic accuracy of the rapid dipstick test to predict urinary tract infection in pregnancy with the gold standard of urine microscopy, culture and sensitivity acting as the control. The urine dipstick test uses the leucocyte esterase, nitrite and test for protein singly and in combination. The result of the dipstick was compared with the gold standard, urine microscopy, culture and sensitivity using confidence interval for proportions. The reliability and validity of the urine dipstick was also evaluated. Overall, the urine dipstick test has a poor correlation with urine culture (p = 0.125, CI 95%). The same holds true for individual components of the dipstick test. The overall sensitivity of the urine dipstick test was poor at 2.3%. Individual sensitivity of the various components varied between 9.1% for leucocyte esterase and the nitrite test to 56.8% for leucocyte esterase alone. The other components of the dipstick test, the test of nitrite, test for protein and combination of the test (leucocyte esterase, nitrite and proteinuria) appear to decrease the sensitivity of the leucocyte esterase test alone. The ability of the urine dipstick test to correctly rule out urinary tract infection (specificity) was high. The positive predictive value for the dipstick test was high, with the leucocyte esterase test having the highest positive predictive value compared with the other components of the dipstick test. The negative predictive value (NPV) was expectedly highest for the leucocyte esterase test alone with values higher than the other components of the urine dipstick test singly and in various combinations. Compared with the other parameters of the urine dipstick test, singly and in combination, leucocyte esterase appears to be the most accurate (90.25%). The dipstick test has a limited use in screening for asymptomatic bacteriuria. The leucocyte esterase test component of the dipstick test appears to have the highest reliability and validity. The other parameters of the dipstick test decreases the reliability and validity of the leucocyte esterase test. A positive test merits empirical antibiotics, while a negative test is an indication for urine culture. The urine dipstick test if positive will also be useful in follow-up of patient after treatment of urinary tract infection. This is useful in poor resource setting especially in the third world where there is a dearth of trained personnel and equipment for urine culture.
Making A D-Latch Sensitive To Alpha Particles
NASA Technical Reports Server (NTRS)
Buehler, Martin G.; Blaes, Brent R.; Nixon, Robert H.
1994-01-01
Standard complementary metal oxide/semiconductor (CMOS) D-latch integrated circuit modified to increase susceptibility to single-event upsets (SEU's) (changes in logic state) caused by impacts of energetic alpha particles. Suitable for use in relatively inexpensive bench-scale SEU tests of itself and of related integrated circuits like static random-access memories.
49 CFR 571.209 - Standard No. 209; Seat belt assemblies.
Code of Federal Regulations, 2010 CFR
2010-10-01
.... (1) Eye bolts, shoulder bolts, or other bolt used to secure the pelvic restraint of seat belt... connecting webbing to an eye bolt shall be provided with a retaining latch or keeper which shall not move...) Single attachment hook for connecting webbing to any eye bolt shall be tested in the following manner...
46 CFR 164.018-5 - Specifications and standards incorporated by reference.
Code of Federal Regulations, 2013 CFR
2013-10-01
... (August 12, 1970), entitled “Cloth, Drill, Cotton.” (4) Federal Specification CCC-C-443 E (December 2, 1974), entitled “Cloth, Duck, Cotton (Single and Plied Filling Yarns, Flat).” (5) Federal Test Method... MIL-C-17415 E (April 16, 1964), entitled “Cloth, Coated, and Webbing, Inflatable Boat and...
46 CFR 164.018-5 - Specifications and standards incorporated by reference.
Code of Federal Regulations, 2011 CFR
2011-10-01
... (August 12, 1970), entitled “Cloth, Drill, Cotton.” (4) Federal Specification CCC-C-443 E (December 2, 1974), entitled “Cloth, Duck, Cotton (Single and Plied Filling Yarns, Flat).” (5) Federal Test Method... MIL-C-17415 E (April 16, 1964), entitled “Cloth, Coated, and Webbing, Inflatable Boat and...
46 CFR 164.018-5 - Specifications and standards incorporated by reference.
Code of Federal Regulations, 2014 CFR
2014-10-01
... (August 12, 1970), entitled “Cloth, Drill, Cotton.” (4) Federal Specification CCC-C-443 E (December 2, 1974), entitled “Cloth, Duck, Cotton (Single and Plied Filling Yarns, Flat).” (5) Federal Test Method... MIL-C-17415 E (April 16, 1964), entitled “Cloth, Coated, and Webbing, Inflatable Boat and...
46 CFR 164.018-5 - Specifications and standards incorporated by reference.
Code of Federal Regulations, 2012 CFR
2012-10-01
... (August 12, 1970), entitled “Cloth, Drill, Cotton.” (4) Federal Specification CCC-C-443 E (December 2, 1974), entitled “Cloth, Duck, Cotton (Single and Plied Filling Yarns, Flat).” (5) Federal Test Method... MIL-C-17415 E (April 16, 1964), entitled “Cloth, Coated, and Webbing, Inflatable Boat and...
Early Numeracy Indicators: Examining Predictive Utility Across Years and States
ERIC Educational Resources Information Center
Conoyer, Sarah J.; Foegen, Anne; Lembke, Erica S.
2016-01-01
Two studies using similar methods in two states investigated the long-term predictive utility of two single-skill early numeracy Curriculum Based Measures (CBMs) and the degree to which they can adequately predict high-stakes test scores. Data were drawn from kindergarten and first-grade students. State standardized assessment data from the…
Epilogue: Reading Comprehension Is Not a Single Ability--Implications for Assessment and Instruction
ERIC Educational Resources Information Center
Kamhi, Alan G.; Catts, Hugh W.
2017-01-01
Purpose: In this epilogue, we review the 4 response articles and highlight the implications of a multidimensional view of reading for the assessment and instruction of reading comprehension. Method: We reiterate the problems with standardized tests of reading comprehension and discuss the advantages and disadvantages of recently developed…
46 CFR 28.40 - Incorporation by reference.
Code of Federal Regulations, 2014 CFR
2014-10-01
... Commandant (CG-ENG), Attn: Office of Design and Engineering Systems, U.S. Coast Guard Stop 7509, 2703 Martin..., PA 19428-2959. ASTM F 1321-92, Standard Guide for Conducting a Stability Test (Lightweight Survey and... Laboratories, Inc. (UL), 12 Laboratory Drive, Research Triangle Park, NC 27709-3995 UL 217-1985—Single and...
46 CFR 28.40 - Incorporation by reference.
Code of Federal Regulations, 2013 CFR
2013-10-01
... Commandant (CG-ENG), Attn: Office of Design and Engineering Systems, U.S. Coast Guard Stop 7509, 2703 Martin..., PA 19428-2959. ASTM F 1321-92, Standard Guide for Conducting a Stability Test (Lightweight Survey and... Laboratories, Inc. (UL), 12 Laboratory Drive, Research Triangle Park, NC 27709-3995 UL 217-1985—Single and...
Fracture Toughness of Advanced Ceramics at Room Temperature
Quinn, George D.; Salem, Jonathan; Bar-on, Isa; Cho, Kyu; Foley, Michael; Fang, Ho
1992-01-01
This report presents the results obtained by the five U.S. participating laboratories in the Versailles Advanced Materials and Standards (VAMAS) round-robin for fracture toughness of advanced ceramics. Three test methods were used: indentation fracture, indentation strength, and single-edge pre-cracked beam. Two materials were tested: a gas-pressure sintered silicon nitride and a zirconia toughened alumina. Consistent results were obtained with the latter two test methods. Interpretation of fracture toughness in the zirconia alumina composite was complicated by R-curve and environmentally-assisted crack growth phenomena. PMID:28053447
Mitigating Upsets in SRAM-Based FPGAs from the Xilinx Virtex 2 Family
NASA Technical Reports Server (NTRS)
Swift, G. M.; Yui, C. C.; Carmichael, C.; Koga, R.; George, J. S.
2003-01-01
Static random access memory (SRAM) upset rates in field programmable gate arrays (FPGAs) from the Xilinx Virtex 2 family have been tested for radiation effects on configuration memory, block RAM and the power-on-reset (POR) and SelectMAP single event functional interrupts (SEFIs). Dynamic testing has shown the effectiveness and value of Triple Module Redundancy (TMR) and partial reconfiguration when used in conjunction. Continuing dynamic testing for more complex designs and other Virtex 2 capabilities (i.e., I/O standards, digital clock managers (DCM), etc.) is scheduled.
Koschate, Jessica; Drescher, Uwe; Baum, Klaus; Brinkmann, Christian; Schiffer, Thorsten; Latsch, Joachim; Brixius, Klara; Hoffmann, Uwe
2017-05-01
The aim of this pilot study was to investigate whether there are differences in heart rate and oxygen uptake kinetics in type 2 diabetes patients, considering their cardiovascular medication. It was hypothesized that cardiovascular medication would affect heart rate and oxygen uptake kinetics and that this could be detected using a standardized exercise test. 18 subjects were tested for maximal oxygen uptake. Kinetics were measured in a single test session with standardized, randomized moderate-intensity work rate changes. Time series analysis was used to estimate kinetics. Greater maxima in cross-correlation functions indicate faster kinetics. 6 patients did not take any cardiovascular medication, 6 subjects took peripherally acting medication and 6 patients were treated with centrally acting medication. Maximum oxygen uptake was not significantly different between groups. Significant main effects were identified regarding differences in muscular oxygen uptake kinetics and heart rate kinetics. Muscular oxygen uptake kinetics were significantly faster than heart rate kinetics in the group with no cardiovascular medication (maximum in cross-correlation function of muscular oxygen uptake vs. heart rate; 0.32±0.08 vs. 0.25±0.06; p=0.001) and in the group taking peripherally acting medication (0.34±0.05 vs. 0.28±0.05; p=0.009) but not in the patients taking centrally acting medication (0.28±0.05 vs. 0.30±0.07; n.s.). It can be concluded that regulatory processes for the achievement of a similar maximal oxygen uptake are different between the groups. The used standardized test provided plausible results for heart rate and oxygen uptake kinetics in a single measurement session in this patient group. © Georg Thieme Verlag KG Stuttgart · New York.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-29
... Professionals: Standard Work Specifications for Single Family Energy Upgrades AGENCY: Office of Energy...: Standard Work Specifications for Single Family Energy Upgrades. This document is a set of work specifications applicable to energy efficiency retrofits of single family homes. These specifications are...
Multiple-taper spectral analysis: A stand-alone C-subroutine
NASA Astrophysics Data System (ADS)
Lees, Jonathan M.; Park, Jeffrey
1995-03-01
A simple set of subroutines in ANSI-C are presented for multiple taper spectrum estimation. The multitaper approach provides an optimal spectrum estimate by minimizing spectral leakage while reducing the variance of the estimate by averaging orthogonal eigenspectrum estimates. The orthogonal tapers are Slepian nπ prolate functions used as tapers on the windowed time series. Because the taper functions are orthogonal, combining them to achieve an average spectrum does not introduce spurious correlations as standard smoothed single-taper estimates do. Furthermore, estimates of the degrees of freedom and F-test values at each frequency provide diagnostics for determining levels of confidence in narrow band (single frequency) periodicities. The program provided is portable and has been tested on both Unix and Macintosh systems.
2016-08-10
IM/CLO) FROM ASTM STANDARD SINGLE WIND VELOCITY MEASURES DISCLAIMER The opinions or assertions contained herein are the private views of the...USARIEM TECHNICAL REPORT T16-14 METHOD FOR ESTIMATING EVAPORATIVE POTENTIAL (IM/CLO) FROM ASTM STANDARD SINGLE WIND VELOCITY...ASTM STANDARD SINGLE WIND VELOCITY MEASURES Adam W. Potter Biophysics and Biomedical Modeling Division U.S. Army Research Institute of Environmental
Demonstration of Standard HVAC Single-Loop Digital Control Systems
1993-01-01
AD-A265 372 T N FEAP-TR-FE-93/05 REPORT January 1993 FACILITIES ENGINEERING APPLICATIONS PROGRAM Demonstration of Standard HVAC Single-Loop Digital...AND DATES COVERED January 1993 Final 4. TITLE AND SUBTITLE [5. FUNDING NUMBERS Demonstration of Standard HVAC Single-Loop Digital Control Systems FEAP...conditioning ( HVAC ) control systems provide guidance on designing and specifying standard HVAC control systems that use single-loop digital controllers
The rationale, development, and standardization of a basic word vocabulary test.
Dupuy, H J
1974-04-01
The results of the studies to date indicate that the Basic Word Vocabulary Test provides a range of items in terms of item difficulty levels useful in printed form from about the third grade to the highest educational levels. Since pictorial and orally given vocabulary tests are used from about ages 2 to 8 years, further work should be done to extend the scale downward so that a single comprehensive vocabulary scale ranging from age 2 years to the highest level of verbal development is available for general use. Validation studies should also be conducted with other well-known intelligence tests so that scores can be compared. Alternate forms need to be developed to allow for longitudinal studies of growth and development. The use of a single standard of measurement of vocabulary development, suitable over a wide range of age and ability levels, by different investigators should materially aid in comparing results across studies and samples and lead to more consistent findings, advances in knowledge, and wider application of findings in practical circumstances, The findings presented in this report indicate that the Basic Word Vocabulary Test adequately measures basic word knowledge acquisition and development. The BWVT is suitable for evaluation of individuals and for use in making group comparisons in levels of basic word knowledge attainment, growth, and development. All material appearing in this report is in the public domain and may be reproduced or copied without permission; citation as to source, however, is appreciated.
NASA Astrophysics Data System (ADS)
Kaiser, Mary Elizabeth; Morris, Matthew; Aldoroty, Lauren; Kurucz, Robert; McCandliss, Stephan; Rauscher, Bernard; Kimble, Randy; Kruk, Jeffrey; Wright, Edward L.; Feldman, Paul; Riess, Adam; Gardner, Jonathon; Bohlin, Ralph; Deustua, Susana; Dixon, Van; Sahnow, David J.; Perlmutter, Saul
2018-01-01
Establishing improved spectrophotometric standards is important for a broad range of missions and is relevant to many astrophysical problems. Systematic errors associated with astrophysical data used to probe fundamental astrophysical questions, such as SNeIa observations used to constrain dark energy theories, now exceed the statistical errors associated with merged databases of these measurements. ACCESS, “Absolute Color Calibration Experiment for Standard Stars”, is a series of rocket-borne sub-orbital missions and ground-based experiments designed to enable improvements in the precision of the astrophysical flux scale through the transfer of absolute laboratory detector standards from the National Institute of Standards and Technology (NIST) to a network of stellar standards with a calibration accuracy of 1% and a spectral resolving power of 500 across the 0.35‑1.7μm bandpass. To achieve this goal ACCESS (1) observes HST/ Calspec stars (2) above the atmosphere to eliminate telluric spectral contaminants (e.g. OH) (3) using a single optical path and (HgCdTe) detector (4) that is calibrated to NIST laboratory standards and (5) monitored on the ground and in-flight using a on-board calibration monitor. The observations are (6) cross-checked and extended through the generation of stellar atmosphere models for the targets. The ACCESS telescope and spectrograph have been designed, fabricated, and integrated. Subsystems have been tested. Performance results for subsystems, operations testing, and the integrated spectrograph will be presented. NASA sounding rocket grant NNX17AC83G supports this work.
Gatenby, J. Christopher; Gore, John C.; Tong, Frank
2012-01-01
High-resolution functional MRI is a leading application for very high field (7 Tesla) human MR imaging. Though higher field strengths promise improvements in signal-to-noise ratios (SNR) and BOLD contrast relative to fMRI at 3 Tesla, these benefits may be partially offset by accompanying increases in geometric distortion and other off-resonance effects. Such effects may be especially pronounced with the single-shot EPI pulse sequences typically used for fMRI at standard field strengths. As an alternative, one might consider multishot pulse sequences, which may lead to somewhat lower temporal SNR than standard EPI, but which are also often substantially less susceptible to off-resonance effects. Here we consider retinotopic mapping of human visual cortex as a practical test case by which to compare examples of these sequence types for high-resolution fMRI at 7 Tesla. We performed polar angle retinotopic mapping at each of 3 isotropic resolutions (2.0, 1.7, and 1.1 mm) using both accelerated single-shot 2D EPI and accelerated multishot 3D gradient-echo pulse sequences. We found that single-shot EPI indeed led to greater temporal SNR and contrast-to-noise ratios (CNR) than the multishot sequences. However, additional distortion correction in postprocessing was required in order to fully realize these advantages, particularly at higher resolutions. The retinotopic maps produced by both sequence types were qualitatively comparable, and showed equivalent test/retest reliability. Thus, when surface-based analyses are planned, or in other circumstances where geometric distortion is of particular concern, multishot pulse sequences could provide a viable alternative to single-shot EPI. PMID:22514646
Swisher, Jascha D; Sexton, John A; Gatenby, J Christopher; Gore, John C; Tong, Frank
2012-01-01
High-resolution functional MRI is a leading application for very high field (7 Tesla) human MR imaging. Though higher field strengths promise improvements in signal-to-noise ratios (SNR) and BOLD contrast relative to fMRI at 3 Tesla, these benefits may be partially offset by accompanying increases in geometric distortion and other off-resonance effects. Such effects may be especially pronounced with the single-shot EPI pulse sequences typically used for fMRI at standard field strengths. As an alternative, one might consider multishot pulse sequences, which may lead to somewhat lower temporal SNR than standard EPI, but which are also often substantially less susceptible to off-resonance effects. Here we consider retinotopic mapping of human visual cortex as a practical test case by which to compare examples of these sequence types for high-resolution fMRI at 7 Tesla. We performed polar angle retinotopic mapping at each of 3 isotropic resolutions (2.0, 1.7, and 1.1 mm) using both accelerated single-shot 2D EPI and accelerated multishot 3D gradient-echo pulse sequences. We found that single-shot EPI indeed led to greater temporal SNR and contrast-to-noise ratios (CNR) than the multishot sequences. However, additional distortion correction in postprocessing was required in order to fully realize these advantages, particularly at higher resolutions. The retinotopic maps produced by both sequence types were qualitatively comparable, and showed equivalent test/retest reliability. Thus, when surface-based analyses are planned, or in other circumstances where geometric distortion is of particular concern, multishot pulse sequences could provide a viable alternative to single-shot EPI.
Nandi, Shyam Sundar; Sharma, Deepa Kailash; Deshpande, Jagadish M
2016-07-01
It is important to understand the role of cell surface receptors in susceptibility to infectious diseases. CD155 a member of the immunoglobulin super family, serves as the poliovirus receptor (PVR). Heterozygous (Ala67Thr) polymorphism in CD155 has been suggested as a risk factor for paralytic outcome of poliovirus infection. The present study pertains to the development of a screening test to detect the single nucleotide (SNP) polymorphism in the CD155 gene. New primers were designed for PCR, sequencing and SNP analysis of Exon2 of CD155 gene. DNAs extracted from either whole blood (n=75) or cells from oral cavity (n=75) were used for standardization and validation of the SNP assay. DNA sequencing was used as the gold standard method. A new SNP assay for detection of heterozygous Ala67Thr genotype was developed and validated by testing 150 DNA samples. Heterozygous CD155 was detected in 27.33 per cent (41/150) of DNA samples tested by both SNP detection assay and sequencing. The SNP detection assay was successfully developed for identification of Ala67Thr polymorphism in human PVR/CD155 gene. The SNP assay will be useful for large scale screening of DNA samples.
Psychomotor and cognitive effects of piribedil, a dopamine agonist, in young healthy volunteers.
Schück, Stéphane; Bentué-Ferrer, Danièle; Kleinermans, Diane; Reymann, Jean-Michel; Polard, Elisabeth; Gandon, Jean-Marc; Allain, Hervé
2002-02-01
Piribedil is a dopamine agonist acting on D2 and D3 central nervous system dopamine receptors. This drug has been administered to 12 young healthy male volunteers (age 22 +/- 2 years) according to a single center randomized, double-blind, two ways cross-over, placebo controlled trial, including a washout period of one week. Placebo and piribedil were administered by a single intravenous infusion over 2 h (3 mg). Psychomotor performance and cognitive functions were assessed through a standardized and computerized psychometric tests battery and a continuous electroencephalogram (EEG) mapping. Piribedil improved simple reaction time (P=0.02), immediate (P=0.045 and 0.004), and delayed free recall (P=0.05), dual coding test (P=0.02) and increased theta and fast beta waves on the EEG (P < 0.05 and 0.001, respectively). No deleterious effect was observed on the tests exploring attention and concentration via the other procedures. It is concluded that a single intravenous perfusion of piribedil 3 mg improves alertness and the information processing speed within the central nervous system, in healthy volunteers.
Anthropometric, physiological and performance characteristics of elite team-handball players.
Chaouachi, Anis; Brughelli, Matt; Levin, Gregory; Boudhina, Nahla Ben Brahim; Cronin, John; Chamari, Karim
2009-01-15
The objective of this study was to provide anthropometric, physiological, and performance characteristics of an elite international handball team. Twenty-one elite handball players were tested and categorized according to their playing positions (goalkeepers, backs, pivots, and wings). Testing consisted of anthropometric and physiological measures of height, body mass, percentage body fat and endurance (VO(2max)), performance measures of speed (5, 10, and 30 m), strength (bench press and squat), unilateral and bilateral horizontal jumping ability, and a 5-jump horizontal test. Significant differences were found between player positions for some anthropometric characteristics (height and percentage body fat) but not for the physiological or performance characteristics. Strong correlations were noted between single leg horizontal jumping distances with 5-, 10-, and 30-m sprint times (r = 0.51-0.80; P < 0.01). The best predictors of sprint times were single leg horizontal jumping with the dominant leg and the distance measured for the 5-jump test, which when combined accounted for 72% of the common variance associated with sprint ability. In conclusion, performance abilities between positions in elite team-handball players appear to be very similar. Single leg horizontal jumping distance could be a specific standardized test for predicting sprinting ability in elite handball players.
Giri, Sidhartha; Rajan, Anand K; Kumar, Nirmal; Dhanapal, Pavithra; Venkatesan, Jayalakshmi; Iturriza-Gomara, Miren; Taniuchi, Mami; John, Jacob; Abraham, Asha Mary; Kang, Gagandeep
2017-08-01
Although, culture is considered the gold standard for poliovirus detection from stool samples, real-time PCR has emerged as a faster and more sensitive alternative. Detection of poliovirus from the stool of recently vaccinated children by culture, single and multiplex real-time PCR was compared. Of the 80 samples tested, 55 (68.75%) were positive by culture compared to 61 (76.25%) and 60 (75%) samples by the single and one step multiplex real-time PCR assays respectively. Real-time PCR (singleplex and multiplex) is more sensitive than culture for poliovirus detection in stool, although the difference was not statistically significant. © 2017 Wiley Periodicals, Inc.
Zhu, Yuying; Wang, Jianmin; Wang, Cunfang
2018-05-01
Taking fresh goat milk as raw material after filtering, centrifuging, hollow fiber ultrafiltration, allocating formula, value detection and preparation processing, a set of 10 goat milk mixed standard substances was prepared on the basis of one-factor-at-a-time using a uniform design method, and its accuracy, uniformity and stability were evaluated by paired t-test and F-test of one-way analysis of variance. The results showed that three milk composition contents of these standard products were independent of each other, and the preparation using the quasi-level design method, and without emulsifier was the best program. Compared with detection value by cow milk standards for calibration fast analyzer, the calibration by goat milk mixed standard was more applicable to rapid detection of goat milk composition, detection value was more accurate and the deviation showed less error. Single factor analysis of variance showed that the uniformity and stability of the mixed standard substance were better; it could be stored for 15 days at 4°C. The uniformity and stability of the in-units and inter-units could meet the requirements of the preparation of national standard products. © 2018 Japanese Society of Animal Science.
Cryogenic rf test of the first SRF cavity etched in an rf Ar/Cl2 plasma
NASA Astrophysics Data System (ADS)
Upadhyay, J.; Palczewski, A.; Popović, S.; Valente-Feliciano, A.-M.; Im, Do; Phillips, H. L.; Vušković, L.
2017-12-01
An apparatus and a method for etching of the inner surfaces of superconducting radio frequency (SRF) accelerator cavities are described. The apparatus is based on the reactive ion etching performed in an Ar/Cl2 cylindrical capacitive discharge with reversed asymmetry. To test the effect of the plasma etching on the cavity rf performance, a 1497 MHz single cell SRF cavity was used. The single cell cavity was mechanically polished and buffer chemically etched and then rf tested at cryogenic temperatures to provide a baseline characterization. The cavity's inner wall was then exposed to the capacitive discharge in a mixture of Argon and Chlorine. The inner wall acted as the grounded electrode, while kept at elevated temperature. The processing was accomplished by axially moving the dc-biased, corrugated inner electrode and the gas flow inlet in a step-wise manner to establish a sequence of longitudinally segmented discharges. The cavity was then tested in a standard vertical test stand at cryogenic temperatures. The rf tests and surface condition results, including the electron field emission elimination, are presented.
Nucleic acid tests for the detection of alpha human papillomaviruses.
Poljak, Mario; Cuzick, Jack; Kocjan, Boštjan J; Iftner, Thomas; Dillner, Joakim; Arbyn, Marc
2012-11-20
Testing for high-risk types of alpha human papillomaviruses (HPV) is an invaluable part of clinical guidelines for cervical carcinoma screening, management and treatment. In this comprehensive inventory of commercial tests for detection of alpha-HPV, we identified at least 125 distinct HPV tests and at least 84 variants of the original tests. However, only a small subset of HPV tests has documented clinical performance for any of the standard HPV testing indications. For more than 75% of HPV tests currently on the market, no single publication in peer-reviewed literature can be identified. HPV tests that have not been validated and lack proof of reliability, reproducibility and accuracy should not be used in clinical management. Once incorporated in the lab, it is essential that the whole procedure of HPV testing is subject to continuous and rigorous quality assurance to avoid sub-optimal, potentially harmful practices. Manufacturers of HPV tests are urged to put more effort into evaluating their current and future products analytically, using international standards, and for clinical applications, using clinically validated endpoints. To assist with analytical validation, the World Health Organization is developing international standards for HPV types other than HPV16 and HPV18 and is planning development of external quality control panels specifically designed to be used for performance evaluation of current and future HPV tests. There is a need for more competitively priced HPV tests, especially for resource-poor countries, and uniform test validation criteria based on international standards should enable issuing more competitive and fair tender notices for purchasing. Automation systems allowing large-scale testing, as well as further increases in clinical performance, are the main needs in the further improvement of HPV tests. This article forms part of a special supplement entitled "Comprehensive Control of HPV Infections and Related Diseases" Vaccine Volume 30, Supplement 5, 2012. Copyright © 2012 Elsevier Ltd. All rights reserved.
Bonnyaud, Céline; Pradon, Didier; Vuillerme, Nicolas; Bensmail, Djamel; Roche, Nicolas
2015-01-01
Background The timed up and go test (TUG) is a functional test which is increasingly used to evaluate patients with stroke. The outcome measured is usually global TUG performance-time. Assessment of spatiotemporal and kinematic parameters during the Oriented gait and Turn sub-tasks of the TUG would provide a better understanding of the mechanisms underlying patients’ performance and therefore may help to guide rehabilitation. The aim of this study was thus to determine the spatiotemporal and kinematic parameters which were most related to the walking and turning sub-tasks of TUG performance in stroke patients. Methods 29 stroke patients carried out the TUG test which was recorded using an optoelectronic system in two conditions: spontaneous and standardized condition (standardized foot position and instructed to turn towards the paretic side). They also underwent a clinical assessment. Stepwise regression was used to determine the parameters most related to Oriented gait and Turn sub-tasks. Relationships between explanatory parameters of Oriented gait and Turn performance and clinical scales were evaluated using Spearman correlations. Results Step length and cadence explained 82% to 95% of the variance for the walking sub-tasks in both conditions. Percentage single support phase and contralateral swing phase (depending on the condition) respectively explained 27% and 56% of the variance during the turning sub-task in the spontaneous and standardized conditions. Discussion and Conclusion Step length, cadence, percentage of paretic single support phase and non-paretic swing phase, as well as dynamic stability were the main parameters related to TUG performance and they should be targeted in rehabilitation. PMID:26091555
Standard specification for light ladders
NASA Astrophysics Data System (ADS)
1980-11-01
Requirements are given for the construction, inspection, and testing of single ladders, extension ladders, step-ladders, extending step-ladders, trestle ladders, extending trestle ladders, and special purpose ladders. The composition of the aluminum alloys, and of the steels and glass fiber reinforced polyester components coming into contact with the aluminum are included. Coatings used to provide corrosion resistance are also specified.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-06
... be active during all dynamic tests conducted to show compliance with Sec. 25.562. (2) The design and... novel or unusual design feature(s) associated with multiple place and single place side- facing seats... not contain adequate or appropriate safety standards for this design feature. These proposed special...
USDA-ARS?s Scientific Manuscript database
Effective laboratory methods for identifying avian influenza virus (AIV) in wild bird populations are crucial to understanding the ecology of this pathogen. The gold standard method has been AIV isolation in chorioallantoic sac (CAS) of specific-pathogen-free (SPF) embryonating chicken eggs (ECE), ...
Using HFire for spatial modeling of fire in shrublands
Seth H. Peterson; Marco E. Morais; Jean M. Carlson; Philip E. Dennison; Dar A. Roberts; Max A. Moritz; David R. Weise
2009-01-01
An efficient raster fire-spread model named HFire is introduced. HFire can simulate single-fire events or long-term fire regimes, using the same fire-spread algorithm. This paper describes the HFire algorithm, benchmarks the model using a standard set of tests developed for FARSITE, and compares historical and predicted fire spread perimeters for three southern...
Prototyping and Characterization of an Adjustable Skew Angle Single Gimbal Control Moment Gyroscope
2015-03-01
performance, and an analysis of the test results is provided. In addition to the standard battery of CMG performance tests that were planned, a...objectives for this new CMG is to provide comparable performance to the Andrews CMGs, the values in Table 1 will be used for output torque comparison...essentially fixed at 53.4°. This specific skew angle value is not the problem, as this is one commonly used CMG skew angle for satellite systems. The real
Single vs. combination immunotherapeutic strategies for glioma
Chandran, Mayuri; Candolfi, Marianela; Shah, Diana; Mineharu, Yohei; Yadav, Vivek; Koschmann, Carl; Asad, Antonela S.; Lowenstein, Pedro R.; Castro, Maria G.
2017-01-01
Introduction Malignant gliomas are highly invasive tumors, associated with a dismal survival rate despite standard of care, which includes surgical resection, radiotherapy and chemotherapy with temozolomide (TMZ). Precision immunotherapies or combinations of immunotherapies that target unique tumor-specific featuresmay substantially improve upon existing treatments. Areas covered Clinical trials of single immunotherapies have shown therapeutic potential in high-grade glioma patients, and emerging preclinical studies indicate that combinations of immunotherapies may be more effective than monotherapies. In this review we discuss emerging combinations of immunotherapies and compare efficacy of single vs. combined therapies tested in preclinical brain tumor models. Expert opinion Malignant gliomas are characterized by a number of factors which may limit the success of single immunotherapies including inter-tumor and intra-tumor heterogeneity, intrinsic resistance to traditional therapies, immunosuppression, and immune selection for tumor cells with low antigenicity. Combination of therapies which target multiple aspects of tumor physiology are likely to be more effective than single therapies. While we describe a limited number of combination immunotherapies which are currently being tested in preclinical and clinical studies, the field is expanding at an astounding rate, and endless combinations remain open for exploration. PMID:28286975
Inflation of Unreefed and Reefed Extraction Parachutes
NASA Technical Reports Server (NTRS)
Ray, Eric S.; Varela, Jose G.
2015-01-01
Data from the Orion and several other test programs have been used to reconstruct inflation parameters for 28 ft Do extraction parachutes as well as the parent aircraft pitch response during extraction. The inflation force generated by extraction parachutes is recorded directly during tow tests but is usually inferred from the payload accelerometer during Low Velocity Airdrop Delivery (LVAD) flight test extractions. Inflation parameters are dependent on the type of parent aircraft, number of canopies, and standard vs. high altitude extraction conditions. For standard altitudes, single canopy inflations are modeled as infinite mass, but the non-symmetric inflations in a cluster are modeled as finite mass. High altitude extractions have necessitated reefing the extraction parachutes, which are best modeled as infinite mass for those conditions. Distributions of aircraft pitch profiles and inflation parameters have been generated for use in Monte Carlo simulations of payload extractions.
NASA Technical Reports Server (NTRS)
Tacina, Robert; Wey, Changlie; Laing, Peter; Mansour, Adel
2002-01-01
A low NO(x) emissions combustor has been demonstrated in flame-tube tests. A multipoint, lean-direct injection concept was used. Configurations were tested that had 25- and 36- fuel injectors in the size of a conventional single fuel injector. An integrated-module approach was used for the construction where chemically etched laminates, diffusion bonded together, combine the fuel injectors, air swirlers and fuel manifold into a single element. Test conditions were inlet temperatures up to 810 K, inlet pressures up to 2760 kPa, and flame temperatures up to 2100 K. A correlation was developed relating the NO(x) emissions with the inlet temperature, inlet pressure, fuel-air ratio and pressure drop. Assuming that 10 percent of the combustion air would be used for liner cooling and using a hypothetical engine cycle, the NO(x) emissions using the correlation from flame-tube tests were estimated to be less than 20 percent of the 1996 ICAO standard.
NASA Technical Reports Server (NTRS)
Schuessler, Philipp WH
2010-01-01
In August 2008, Schuessler Consulting was contracted by NASA GSFC in support of the NASA Electronic Parts and Packaging (NEPP) program to perform two separate studies on moisture laden air in a stainless steel cylinder that had been designed to become a consensus standard for Test Method 1018. This Test Method was originally released for hybrids under Mil. Std. 883 but was quickly utilized on other microelectronic devices under the auspice of Mil. Std. 750. The cylinder had subsequently been fabricated for the 750 community. It was back-filled with moist air and subsequently analyzed over a period of time under a previous NASA contract. It had been shown that moisture in the 4000 - 5000 ppm range could be analyzed rather precisely with a mass spectrometer, commonly referred to as a Residual Gas Analyzer (RGA). The scope of this study was to ascertain if the composition and precision varied as a function of thermal shock at sub-zero temperatures and whether there was consensus when the standard was submitted to other RGA units. It was demonstrated and published that the consensus standard would yield precise RGA data for moisture within +/- 1% when optimized for a given RGA unit. It has been subsequently shown in this study at Oneida Research Services, that sub-zero storage did not affect that precision when a well-defined protocol for the analysis was followed. The consensus standard was taken to a second facility for analysis where it was found that moisture adsorption on the transfer lines caused precision to drop to +/- 12%. The Single Sample Cylinder (SSC) is a one liter stainless steel cylinder with associated sampling valves and has considerable weight and volume. But this considerable size allows for approximately 300 gas samples of the same composition to be delivered to any RGA unit. Lastly, a smaller cylinder, approximately 75 cc, of a second consensus standard was fabricated and tested with a different mix of fixed gases where moisture was kept in the 100 ppm range. This second standard has the potential of providing 30 gaseous samples and can be readily shipped to any analytical facility that desires to generate comparison RGA data. A series of comparison residual gas analyses was performed at the Honeywell Federal Manufacturing & Technologies facility in the National Nuclear Facility Administration s plant in Kansas City to complete this project. It was shown that improvements in the precision of a given RGA unit can be done by controlling the cycle time for each analysis and increasing analysis temperatures to minimize moisture adsorption. It was also found that a "one time event" in the subzero storage of the large SSC did not effect the units ability to continuously supply precise samples of the same chemistry, however the "event" caused a permanent +8% shift in the reported value of the moisture content. Lastly, a set of SSC RGA results was plotted on a common graph with DSCC "correlation study" RGA data. The result demonstrates the ability of the SSC to remove many of the individual variances that single, individual samples introduce. The consensus standards are now in storage at Oneida Research Services, one of the DSCC certified houses that does RGA to Military Standards, where they await future studies. The analytical data and the operational parameters of the instruments used are provided in the following discussion. Limitations and suggested means for improvement of both precision and accuracy are provided.
Gandolfini, I.; Buzio, C.; Zanelli, P.; Palmisano, A.; Cremaschi, E.; Vaglio, A.; Piotti, G.; Melfa, L.; La Manna, G.; Feliciangeli, G.; Cappuccilli, M.; Scolari, M.P.; Capelli, I.; Panicali, L.; Baraldi, O.; Stefoni, S.; Buscaroli, A.; Ridolfi, L.; D'Errico, A.; Cappelli, G.; Bonucchi, D.; Rubbiani, E.; Albertazzi, A.; Mehrotra, A.; Cravedi, P.; Maggiore, U.
2015-01-01
Pre-transplant donor biopsy (PTDB)-based marginal-donor allocation systems to single or dual renal transplantation could increase the use of organs with Kidney Donor Profile Index (KDPI) in the highest range (e.g. >80 or >90), whose discard rate approximates 50% in the US. To test this hypothesis, we retrospectively calculated the KDPI and analyzed the outcomes of 442 marginal kidney transplants (340 single transplants: 278 with a PTDB Remuzzi score <4 [median KDPI:87; interquartile range(IQR):78-94] and 62 with a score =4 [median KDPI:87; IQR:76-93]; 102 dual transplants [median KDPI: 93; IQR:86-96]) and 248 single standard transplant controls [median KDPI:36; IQR:18-51]. PTDB-based allocation of marginal grafts led to a limited discard rate of 15% for kidneys with KDPI of 80-90 and of 37% for kidneys with a KDPI of 91-100. Although 1-year eGFRs were significantly lower in recipients of marginal kidneys (-9.3, -17.9, and -18.8ml/min, for dual transplants, single kidneys with PTDB score <4, and =4, respectively; P<0.001), graft survival (median follow-up 3.3 years) was similar between marginal and standard kidney transplants (hazard ratio: 1.20 [95% confidence interval: 0.80 to 1.79; P=0.38]). In conclusion, PTDB-based allocation allows the safe transplantation of kidneys with KDPI in the highest range that may otherwise be discarded. PMID:25155294
Novel approaches to analysis by flow injection gradient titration.
Wójtowicz, Marzena; Kozak, Joanna; Kościelniak, Paweł
2007-09-26
Two novel procedures for flow injection gradient titration with the use of a single stock standard solution are proposed. In the multi-point single-line (MP-SL) method the calibration graph is constructed on the basis of a set of standard solutions, which are generated in a standard reservoir and subsequently injected into the titrant. According to the single-point multi-line (SP-ML) procedure the standard solution and a sample are injected into the titrant stream from four loops of different capacities, hence four calibration graphs are able to be constructed and the analytical result is calculated on the basis of a generalized slope of these graphs. Both approaches have been tested on the example of spectrophotometric acid-base titration of hydrochloric and acetic acids with using bromothymol blue and phenolphthalein as indicators, respectively, and sodium hydroxide as a titrant. Under optimized experimental conditions the analytical results of precision less than 1.8 and 2.5% (RSD) and of accuracy less than 3.0 and 5.4% (relative error (RE)) were obtained for MP-SL and SP-ML procedures, respectively, in ranges of 0.0031-0.0631 mol L(-1) for samples of hydrochloric acid and of 0.1680-1.7600 mol L(-1) for samples of acetic acid. The feasibility of both methods was illustrated by applying them to the total acidity determination in vinegar samples with precision lower than 0.5 and 2.9% (RSD) for MP-SL and SP-ML procedures, respectively.
The Development of a Pediatric Inpatient Experience of Care Measure: Child HCAHPS®
Toomey, Sara L.; Zaslavsky, Alan M.; Elliott, Marc N.; Gallagher, Patricia M.; Fowler, Floyd J.; Klein, David J.; Shulman, Shanna; Ratner, Jessica; McGovern, Caitriona; LeBlanc, Jessica L.; Schuster, Mark A.
2016-01-01
CMS uses Adult HCAHPS® scores for public reporting and pay-for-performance for most U.S. hospitals, but no publicly available standardized survey of inpatient experience of care exists for pediatrics. To fill the gap, CMS/AHRQ commissioned the development of the Consumer Assessment of Healthcare Providers and Systems Hospital Survey – Child Version (Child HCAHPS), a survey of parents/guardians of pediatric patients (<18 years old) who were recently hospitalized. This Special Article describes the development of Child HCAHPS, which included an extensive review of the literature and quality measures, expert interviews, focus groups, cognitive testing, pilot testing of the draft survey, a national field test with 69 hospitals in 34 states, psychometric analysis, and end-user testing of the final survey. We conducted extensive validity and reliability testing to determine which items would be included in the final survey instrument and to develop composite measures. We analyzed national field test data from 17,727 surveys collected from 11/12-1/14 from parents of recently hospitalized children. The final Child HCAHPS instrument has 62 items, including 39 patient experience items, 10 screeners, 12 demographic/descriptive items, and 1 open-ended item. The 39 experience items are categorized based on testing into 18 composite and single-item measures. Our composite and single-item measures demonstrated good to excellent hospital-level reliability at 300 responses per hospital. Child HCAHPS was developed to be a publicly available standardized survey of pediatric inpatient experience of care. It can be used to benchmark pediatric inpatient experience across hospitals and assist in efforts to improve the quality of inpatient care. PMID:26195542
Matching Automatic Gain Control Across Devices in Bimodal Cochlear Implant Users.
Veugen, Lidwien C E; Chalupper, Josef; Snik, Ad F M; Opstal, A John van; Mens, Lucas H M
2016-01-01
The purpose of this study was to improve bimodal benefit in listeners using a cochlear implant (CI) and a hearing aid (HA) in contralateral ears, by matching the time constants and the number of compression channels of the automatic gain control (AGC) of the HA to the CI. Equivalent AGC was hypothesized to support a balanced loudness for dynamically changing signals like speech and improve bimodal benefit for speech understanding in quiet and with noise presented from the side(s) at 90 degree. Fifteen subjects participated in the study, all using the same Advanced Bionics Harmony CI processor and HA (Phonak Naida S IX UP). In a 3-visit crossover design with 4 weeks between sessions, performance was measured using a HA with a standard AGC (syllabic multichannel compression with 1 ms attack time and 50 ms release time) or an AGC that was adjusted to match that of the CI processor (dual AGC broadband compression, 3 and 240 msec attack time, 80 and 1500 msec release time). In all devices, the AGC was activated above the threshold of 63 dB SPL. The authors balanced loudness across the devices for soft and loud input sounds in 3 frequency bands (0 to 548, 548 to 1000, and >1000 Hz). Speech understanding was tested in free field in quiet and in noise for three spatial speaker configurations, with target speech always presented from the front. Single-talker noise was either presented from the CI side or the HA side, or uncorrelated stationary speech-weighted noise or single-talker noise was presented from both sides. Questionnaires were administered to assess differences in perception between the two bimodal fittings. Significant bimodal benefit over the CI alone was only found for the AGC-matched HA for the speech tests with single-talker noise. Compared with the standard HA, matched AGC characteristics significantly improved speech understanding in single-talker noise by 1.9 dB when noise was presented from the HA side. AGC matching increased bimodal benefit insignificantly by 0.6 dB when noise was presented from the CI implanted side, or by 0.8 (single-talker noise) and 1.1 dB (stationary noise) in the more complex configurations with two simultaneous maskers from both sides. In questionnaires, subjects rated the AGC-matched HA higher than the standard HA for understanding of one person in quiet and in noise, and for the quality of sounds. Listening to a slightly raised voice, subjects indicated increased listening comfort with matched AGCs. At the end of the study, 9 of 15 subjects preferred to take home the AGC-matched HA, 1 preferred the standard HA and 5 subjects had no preference. For bimodal listening, the AGC-matched HA outperformed the standard HA in speech understanding in noise tasks using a single competing talker and it was favored in questionnaires and in a subjective preference test. When noise was presented from the HA side, AGC matching resulted in a 1.9 dB SNR additional benefit, even though the HA was at the least favorable SNR side in this speaker configuration. Our results possibly suggest better binaural processing for matched AGCs.
DeSantis, Michael C; DeCenzo, Shawn H; Li, Je-Luen; Wang, Y M
2010-03-29
Standard deviation measurements of intensity profiles of stationary single fluorescent molecules are useful for studying axial localization, molecular orientation, and a fluorescence imaging system's spatial resolution. Here we report on the analysis of the precision of standard deviation measurements of intensity profiles of single fluorescent molecules imaged using an EMCCD camera.We have developed an analytical expression for the standard deviation measurement error of a single image which is a function of the total number of detected photons, the background photon noise, and the camera pixel size. The theoretical results agree well with the experimental, simulation, and numerical integration results. Using this expression, we show that single-molecule standard deviation measurements offer nanometer precision for a large range of experimental parameters.
Color Vision and the Railways: Part 1. The Railway LED Lantern Test.
Dain, Stephen J; Casolin, Armand; Long, Jennifer; Hilmi, Mohd Radzi
2015-02-01
Lantern tests and practical tests are often used in the assessment of prospective railway employees. The lantern tests rarely embody the actual colors used in signaling on the railways. Practical tests have a number of problems, most notably consistency of application and practicability. This work was carried out to provide the Railway LED Lantern Test (RLLT) as a validated method of assessing the color vision of railway workers. The RLLT, a simulated practical test using the same LEDs (light-emitting diodes) as are used in modern railway signals, was developed. It was tested on 46 color vision-normal (CVN) and 37 color vision-deficient (CVD) subjects. A modified prototype was then tested on 106 CVN subjects. All 106 CVN subjects and most mildly affected CVD subjects passed the modified lantern at 3 m. At 6 m, 1 of the 106 normal color vision subjects failed by missing a single red light. All the CVD subjects failed. The RLLT carried out at 3 m allowed mildly affected CVD subjects to pass and demonstrate adequate color vision for the less demanding railway tasks. Carried out at 6 m, it essentially reinforced normal color vision as the standard. The RLLT is a simply administered test that has a direct link to the actual visual task of the rail worker. The RLLT lantern has been adopted as an approved test in the Australian National Standard for Health Assessment of Rail Safety Workers in place of a practical test. It has the potential to be a valid part of any railway color vision standard.
Comparative tests of bench equipment for fuel control system testing of gas-turbine engine
NASA Astrophysics Data System (ADS)
Shendaleva, E. V.
2018-04-01
The relevance of interlaboratory comparative researches is confirmed by attention of world metrological community to this field of activity. Use of the interlaboratory comparative research methodology not only for single gages collation, but also for bench equipment complexes, such as modeling stands for fuel control system testing of gas-turbine engine, is offered. In this case a comparative measure of different bench equipment will be the control fuel pump. Ensuring traceability of measuring result received at test benches of various air enterprises, development and introduction of national standards to practice of bench tests and, eventually, improvement of quality and safety of a aircraft equipment is result of this approach.
Guidelines for Standardized Testing of Broadband Seismometers and Accelerometers
Hutt, Charles R.; Evans, John R.; Followill, Fred; Nigbor, Robert L.; Wielandt, Erhard
2010-01-01
Testing and specification of seismic and earthquake-engineering sensors and recorders has been marked by significant variations in procedures and selected parameters. These variations cause difficulty in comparing such specifications and test results. In July 1989, and again in May 2005, the U.S. Geological Survey hosted international pub-lic/private workshops with the goal of defining widely accepted guidelines for the testing of seismological inertial sensors, seismometers, and accelerometers. The Proceedings of the 2005 workshop have been published and include as appendix 6 the report of the 1989 workshop. This document represents a collation and rationalization of a single set of formal guidelines for testing and specifying broadband seismometers and accelerometers.
Gismervik, Sigmund Ø; Drogset, Jon O; Granviken, Fredrik; Rø, Magne; Leivseth, Gunnar
2017-01-25
Physical examination tests of the shoulder (PETS) are clinical examination maneuvers designed to aid the assessment of shoulder complaints. Despite more than 180 PETS described in the literature, evidence of their validity and usefulness in diagnosing the shoulder is questioned. This meta-analysis aims to use diagnostic odds ratio (DOR) to evaluate how much PETS shift overall probability and to rank the test performance of single PETS in order to aid the clinician's choice of which tests to use. This study adheres to the principles outlined in the Cochrane guidelines and the PRISMA statement. A fixed effect model was used to assess the overall diagnostic validity of PETS by pooling DOR for different PETS with similar biomechanical rationale when possible. Single PETS were assessed and ranked by DOR. Clinical performance was assessed by sensitivity, specificity, accuracy and likelihood ratio. Six thousand nine-hundred abstracts and 202 full-text articles were assessed for eligibility; 20 articles were eligible and data from 11 articles could be included in the meta-analysis. All PETS for SLAP (superior labral anterior posterior) lesions pooled gave a DOR of 1.38 [1.13, 1.69]. The Supraspinatus test for any full thickness rotator cuff tear obtained the highest DOR of 9.24 (sensitivity was 0.74, specificity 0.77). Compression-Rotation test obtained the highest DOR (6.36) among single PETS for SLAP lesions (sensitivity 0.43, specificity 0.89) and Hawkins test obtained the highest DOR (2.86) for impingement syndrome (sensitivity 0.58, specificity 0.67). No single PETS showed superior clinical test performance. The clinical performance of single PETS is limited. However, when the different PETS for SLAP lesions were pooled, we found a statistical significant change in post-test probability indicating an overall statistical validity. We suggest that clinicians choose their PETS among those with the highest pooled DOR and to assess validity to their own specific clinical settings, review the inclusion criteria of the included primary studies. We further propose that future studies on the validity of PETS use randomized research designs rather than the accuracy design relying less on well-established gold standard reference tests and efficient treatment options.
Do Chinese Readers Follow the National Standard Rules for Word Segmentation during Reading?
Liu, Ping-Ping; Li, Wei-Jun; Lin, Nan; Li, Xing-Shan
2013-01-01
We conducted a preliminary study to examine whether Chinese readers’ spontaneous word segmentation processing is consistent with the national standard rules of word segmentation based on the Contemporary Chinese language word segmentation specification for information processing (CCLWSSIP). Participants were asked to segment Chinese sentences into individual words according to their prior knowledge of words. The results showed that Chinese readers did not follow the segmentation rules of the CCLWSSIP, and their word segmentation processing was influenced by the syntactic categories of consecutive words. In many cases, the participants did not consider the auxiliary words, adverbs, adjectives, nouns, verbs, numerals and quantifiers as single word units. Generally, Chinese readers tended to combine function words with content words to form single word units, indicating they were inclined to chunk single words into large information units during word segmentation. Additionally, the “overextension of monosyllable words” hypothesis was tested and it might need to be corrected to some degree, implying that word length have an implicit influence on Chinese readers’ segmentation processing. Implications of these results for models of word recognition and eye movement control are discussed. PMID:23408981
Single-Tier Testing with the C6 Peptide ELISA Kit Compared with Two-Tier Testing for Lyme Disease
Wormser, Gary P.; Schriefer, Martin; Aguero-Rosenfeld, Maria E.; Levin, Andrew; Steere, Allen C.; Nadelman, Robert B.; Nowakowski, John; Marques, Adriana; Johnson, Barbara J. B.; Dumler, J. Stephen
2014-01-01
Background The two-tier serologic testing protocol for Lyme disease has a number of shortcomings including low sensitivity in early disease; increased cost, time and labor; and subjectivity in the interpretation of immunoblots. Methods The diagnostic accuracy of a single-tier commercial C6 ELISA kit was compared with two-tier testing. Results The C6 ELISA was significantly more sensitive than two-tier testing with sensitivities of 66.5% (95% C.I.:61.7-71.1) and 35.2% (95%C.I.:30.6-40.1), respectively (p<0.001) in 403 sera from patients with erythema migrans. The C6 ELISA had sensitivity statistically comparable to two-tier testing in sera from Lyme disease patients with early neurological manifestations (88.6% vs. 77.3%, p=0.13) or arthritis (98.3% vs. 95.6%, p= 0.38). Te specificities of C6 ELISA and two-tier testing in over 2200 blood donors, patients with other conditions, and Lyme disease vaccine recipients were found to be 98.9% and 99.5%, respectively (p<0.05, 95% C.I. surrounding the 0.6 percentage point difference of 0.04 to 1.15). Conclusions Using a reference standard of two-tier testing, the C6 ELISA as a single step serodiagnostic test provided increased sensitivity in early Lyme disease with comparable sensitivity in later manifestations of Lyme disease. The C6 ELISA had slightly decreased specificity. Future studies should evaluate the performance of the C6 ELISA compared with two-tier testing in routine clinical practice. PMID:23062467
A method for predicting the noise levels of coannular jets with inverted velocity profiles
NASA Technical Reports Server (NTRS)
Russell, J. W.
1979-01-01
A coannular jet was equated with a single stream equivalent jet with the same mass flow, energy, and thrust. The acoustic characteristics of the coannular jet were then related to the acoustic characteristics of the single jet. Forward flight effects were included by incorporating a forward exponent, a Doppler amplification factor, and a Strouhal frequency shift. Model test data, including 48 static cases and 22 wind tunnel cases, were used to evaluate the prediction method. For the static cases and the low forward velocity wind tunnel cases, the spectral mean square pressure correlation coefficients were generally greater than 90 percent, and the spectral sound pressure level standard deviation were generally less than 3 decibels. The correlation coefficient and the standard deviation were not affected by changes in equivalent jet velocity. Limitations of the prediction method are also presented.
Klump, S P; Allred, M C; MacDonald, J L; Ballam, J M
2001-01-01
Isoflavones are biologically active compounds occurring naturally in a variety of plants, with relatively high levels found in soybeans. Twelve laboratories participated in a collaborative study to determine the aglycon isoflavone content of 8 test samples of soy and foods containing soy. The analytical method for the determination of isoflavones incorporates a mild saponification step that reduces the number of analytes measured and permits quantitation versus commercially available, stable reference standards. Test samples were extracted at 65 degrees C with methanol-water (80 + 20), saponified with dilute sodium hydroxide solution, and analyzed by reversed-phase liquid chromatography with UV detection at 260 nm. Isoflavone results were reported as microg/aglycon/g or microg aglycon equivalents/g. The 8 test samples included 2 blind duplicates and 4 single test samples with total isoflavone concentrations ranging from approximately 50 to 3000 microg/g. Test samples of soy ingredients and products made with soy were distributed to collaborators with appropriate reference standards. Collaborators were asked to analyze test samples in duplicate on 2 separate days. The data were analyzed for individual isoflavone components, subtotals of daidzin-daidzein, glycitin-glycitein, and genistin-genistein, and total isoflavones. The relative standard deviation (RSD) for repeatability was 1.8-7.1%, and the RSD for reproducibility was 3.2-16.1% for total isoflavone values of 47-3099 microg/g.
Analysis of a Single Year of Performance Data for Thin Film Modules Deployed at NREL and NISE
DOE Office of Scientific and Technical Information (OSTI.GOV)
MacAlpine, Sara; Deceglie, Michael; Kurtz, Sarah
2016-08-01
The National Renewable Energy Laboratory (NREL) and National Institute of Solar Energy (NISE), located in the United States and India, respectively, have partnered to deploy and monitor modules of three different thin film technologies, to compare the performance and/or degradation between the two sites. This report analyzes a single year of performance data (May 2014 -- May 2015) for the three thin film technologies, exploring the modules' performance under standard test conditions and monthly performance ratios, as well as fill factors varying season, light level, and temperature.
Castelli, Letizia; Stocchi, Luca; Patrignani, Maurizio; Sellitto, Giovanni; Giuliani, Manuela; Prosperini, Luca
2015-12-15
This study was aimed at investigating whether postural sway measures derived from a standard force platform were similar to those generated by a custom-written software ("We-Measure") acquiring and processing data from a commercial Nintendo balance board (BB). For this purpose, 90 patients with multiple sclerosis (MS) and 50 healthy controls (HC) were tested in a single-day session with a reference standard force platform and a BB-based system. Despite its acceptable between-device agreement (tested by visual evaluation of Bland-Altman plot), the low-cost BB-based system tended to overestimate postural sway when compared to the reference standard force platform in both MS and HC groups (on average +30% and +54%, respectively). Between-device reliability was just adequate (MS: 66%, HC: 47%), while test-retest reliability was excellent (MS: 84%, HC: 88%). Concurrent validity evaluation showed similar performance between the reference standard force platform and the BB-based system in discriminating fallers and non-fallers among patients with MS. All these findings may encourage the use of this balance board-based new device in longitudinal study, rather than in cross-sectional design, thus providing a potential useful tool for multicenter settings. Copyright © 2015 Elsevier B.V. All rights reserved.
An entropy-based statistic for genomewide association studies.
Zhao, Jinying; Boerwinkle, Eric; Xiong, Momiao
2005-07-01
Efficient genotyping methods and the availability of a large collection of single-nucleotide polymorphisms provide valuable tools for genetic studies of human disease. The standard chi2 statistic for case-control studies, which uses a linear function of allele frequencies, has limited power when the number of marker loci is large. We introduce a novel test statistic for genetic association studies that uses Shannon entropy and a nonlinear function of allele frequencies to amplify the differences in allele and haplotype frequencies to maintain statistical power with large numbers of marker loci. We investigate the relationship between the entropy-based test statistic and the standard chi2 statistic and show that, in most cases, the power of the entropy-based statistic is greater than that of the standard chi2 statistic. The distribution of the entropy-based statistic and the type I error rates are validated using simulation studies. Finally, we apply the new entropy-based test statistic to two real data sets, one for the COMT gene and schizophrenia and one for the MMP-2 gene and esophageal carcinoma, to evaluate the performance of the new method for genetic association studies. The results show that the entropy-based statistic obtained smaller P values than did the standard chi2 statistic.
X-ray Fluorescence Spectroscopy Study of Coating Thickness and Base Metal Composition
NASA Technical Reports Server (NTRS)
Rolin, T. D.; Leszczuk, Y.
2008-01-01
For electrical, electronic, and electromechanical (EEE) parts to be approved for space use, they must be able to meet safety standards approved by NASA. A fast, reliable, and precise method is needed to make sure these standards are met. Many EEE parts are coated in gold (Au) and nickel (Ni), and the thickness coating is crucial to a part s performance. A nondestructive method that is efficient in measuring coating thickness is x-ray fluorescence (XRF) spectroscopy. The XRF spectrometer is a machine designed to measure layer thickness and composition of single or multilayered samples. By understanding the limitations in the collection of the data by this method, accurate composition and thickness measurements can be obtained for samples with Au and Ni coatings. To understand the limitations of data found, measurements were taken with the XRF spectrometer and compared to true values of standard reference materials (SRM) that were National Institute of Standards and Technology (NIST) traceable. For every sample, six different parameters were varied to understand measurement error: coating/substrate combination, number of layers, counting interval, collimator size, coating thickness, and test area location. Each measurement was taken in accordance with standards set by the American Society for Testing and Materials (ASTM) International Standard B 568.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-18
... DEPARTMENT OF ENERGY Office of Energy Efficiency and Renewable Energy Guidelines for Home Energy... for Home Energy Professionals: Standard Work Specifications for Single Family Energy Upgrades was...: Comments on the Guidelines for Home Energy Professionals: Standard Work Specifications for Single Family...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-20
... edition 2011- Withdrawn and replaced 09-01 Infusion equipment for with newer version. medical use--Part 1: Infusion glass bottles. 6-175 ASTM D5151-06 (Reapproved Reaffirmation. 2011) Standard Test Method for... single use. 6-242 ISO 8536-2 Third edition 2010- Contact person. 03-15, Infusion equipment for medical...
Orifice Mass Flow Calculation in NASA's W-8 Single Stage Axial Compressor Facility
NASA Technical Reports Server (NTRS)
Bozak, Richard F.
2018-01-01
Updates to the orifice mass flow calculation for the W-8 Single Stage Axial Compressor Facility at NASA Glenn Research Center are provided to include the effect of humidity and incorporate ISO 5167. A methodology for including the effect of humidity into the inlet orifice mass flow calculation is provided. Orifice mass flow calculations provided by ASME PTC-19.5-2004, ASME MFC-3M-2004, ASME Fluid Meters, and ISO 5167 are compared for W-8's atmospheric inlet orifice plate. Differences in expansion factor and discharge coefficient given by these standards give a variation of about +/- 75% mass flow except for a few cases. A comparison of the calculations with an inlet static pressure mass flow correlation and a fan exit mass flow integration using test data from a 2017 turbofan rotor test in W-8 show good agreement between the inlet static pressure mass flow correlation, ISO 5167, and ASME Fluid Meters. While W-8's atmospheric inlet orifice plate violates the pipe diameter limit defined by each of the standards, the ISO 5167 is chosen to be the primary orifice mass flow calculation to use in the W-8 facility.
A Single-Block TRL Test Fixture for the Cryogenic Characterization of Planar Microwave Components
NASA Technical Reports Server (NTRS)
Mejia, M.; Creason, A. S.; Toncich, S. S.; Ebihara, B. T.; Miranda, F. A.
1996-01-01
The High-Temperature-Superconductivity (HTS) group of the RF Technology Branch, Space Electronics Division, is actively involved in the fabrication and cryogenic characterization of planar microwave components for space applications. This process requires fast, reliable, and accurate measurement techniques not readily available. A new calibration standard/test fixture that enhances the integrity and reliability of the component characterization process has been developed. The fixture consists of 50 omega thru, reflect, delay, and device under test gold lines etched onto a 254 microns (0.010 in) thick alumina substrate. The Thru-Reflect-Line (TRL) fixture was tested at room temperature using a 30 omega, 7.62 mm (300 mil) long, gold line as a known standard. Good agreement between the experimental data and the data modelled using Sonnet's em(C) software was obtained for both the return (S(sub 11)) and insertion (S( 21)) losses. A gold two-pole bandpass filter with a 7.3 GHz center frequency was used as our Device Under Test (DUT), and the results compared with those obtained using a Short-Open-Load-Thru (SOLT) calibration technique.
Eitzen, Ingrid; Moksnes, Håvard; Snyder-Mackler, Lynn; Risberg, May Arna
2010-11-01
Prospective cohort study without a control group. Firstly, to present our 5-week progressive exercise therapy program in the early stage after anterior cruciate ligament (ACL) injury. Secondly, to evaluate changes in knee function after completion of the program for patients with ACL injury in general and also when classified as potential copers or noncopers, and, finally, to examine potential adverse events. Few studies concerning early-stage ACL rehabilitation protocols exist. Consequently, little is known about the tolerance for, and outcomes from, short-term exercise therapy programs in the early stage after injury. One-hundred patients were included in a 5-week progressive exercise therapy program, within 3 months after injury. Knee function before and after completion of the program was evaluated from isokinetic quadriceps and hamstrings muscle strength tests, 4 single-leg hop tests, 2 different self-assessment questionnaires, and a global rating of knee function. A 2-way mixed-model analysis of variance was conducted to evaluate changes from pretest to posttest for the limb symmetry index for muscle strength and single-leg hop tests, and the change in scores for the patient-reported questionnaires. In addition, absolute values and the standardized response mean for muscle strength and single-leg hop tests were calculated at pretest and posttest for the injured and uninjured limb. Adverse events during the 5-week period were recorded. The progressive 5-week exercise therapy program led to significant improvements (P<.05) in knee function from pretest to posttest both for patients classified as potential copers and noncopers. Standardized response mean values for changes in muscle strength and single-leg hop performance from pretest to posttest for the injured limb were moderate to strong (0.49-0.84), indicating the observed improvements to be clinically relevant. Adverse events occurred in 3.9% of the patients. Short-term progressive exercise therapy programs are well tolerated and should be incorporated in early-stage ACL rehabilitation, either to improve knee function before ACL reconstruction or as a first step in further nonoperative management. Therapy, level 2b.
Safety of externally stimulated intracranial electrodes during functional MRI at 1.5T.
Bhattacharyya, Pallab K; Mullin, Jeffery; Lee, Bryan S; Gonzalez-Martinez, Jorge A; Jones, Stephen E
2017-05-01
Surgical resection of the epileptogenic zone (EZ) is a potential cure for medically refractory focal epilepsy. Proper identification of the EZ is essential for such resection. Synergistic application of functional magnetic resonance imaging (fMRI) simultaneously with stimulation of a single externalized intracranial stereotactic EEG (SEEG) electrode has the potential to improve identification of the EZ. While most EEG-fMRI studies use the electrodes passively to record electrical activity, it is possible to stimulate the brain using the electrodes by connecting them with conducting cables to the stimulation hardware. In this study, we investigated the effect of MRI-induced heating on a single SEEG electrode and its sensitivity to geometry, configuration, and associated connections required for the stimulation. The temperature increase of a single electrode embedded within a gel phantom and connected to an external stimulation system was measured during 1.5T MRI scans using adjacent fluoroptic temperature sensors. A receive-only split-array head coil and a transmit-receive head coil were used for testing. Sequences included a standard localizer, T1-weighted axial fast low-angle shot (FLASH), gradient echo-planar imaging (GE-EPI) axial fMRI, and a high specific absorption rate T2-weighted turbo spin-echo (TSE) axial scan. Variations of the electrode location and connecting cable configuration were tested. No unacceptable heating was observed with the standard sequences used for evaluation of the EZ. Considerable heating (up to 14°C) was observed with the TSE sequence, which is not used clinically. The temperature increase was insignificant (<0.05°C) for electrode contacts closest to the isocenter and connecting cables lying along the isocenter, and varied with configurations of the connecting cable assembly. Simultaneous intracranial electrode stimulation during fMRI using an externalized stimulation system may be safe with strict adherence to settings tested prior to the fMRI. Localizer, FLASH, and GE-EPI fMRI may be safely performed in patients with a single SEEG electrode following the configurations tested in this study, but high SAR TSE scans should not be performed in these patients. Copyright © 2017 Elsevier Inc. All rights reserved.
Warheit, David B; Donner, E Maria
2015-06-01
A recent review article critically assessed the effectiveness of published research articles in nanotoxicology to meaningfully address health and safety issues for workers and consumers. The main conclusions were that, based on a number of flaws in study designs, the potential risk from exposures to nanomaterials is highly exaggerated, and that no 'nano-specific' adverse effects, different from exposures to bulk particles, have been convincingly demonstrated. In this brief editorial we focus on a related tangential issue which potentially compromises the integrity of basic risk science. We note that some single investigation studies report specious toxicity findings, which make the conclusions more alarming and attractive and publication worthy. In contrast, the standardized, carefully conducted, 'guideline study results' are often ignored because they can frequently report no adverse effects; and as a consequence are not considered as novel findings for publication purposes, and therefore they are never considered as newsworthy in the popular press. Yet it is the Organization for Economic Cooperation and Development (OECD) type test guideline studies that are the most reliable for conducting risk assessments. To contrast these styles and approaches, we present the results of a single study which reports high toxicological effects in rats following low-dose, short-term oral exposures to nanoscale titanium dioxide particles concomitant with selective investigative analyses. Alternatively, the findings of OECD test guideline 408, standardized guideline oral toxicity studies conducted for 90 days at much higher doses (1000 mg kg -1 ) in male and female rats demonstrated no adverse effects following a very thorough and complete clinical chemical, as well as histopathological evaluation of all of the relevant organs in the body. This discrepancy in study findings is not reconciled by the fact that several biokinetic studies in rats and humans demonstrate little or no uptake of nanoscale or pigment-grade TiO 2 particles following oral exposures. We conclude that to develop a competent risk assessment profile, results derived from standardized, guideline-type studies, and even 'no effect' study findings provide critically useful input for assessing safe levels of exposure; and should, in principle, be readily acceptable for publication in peer-reviewed toxicology journals. This is a necessary prerequisite for developing a complete dataset for risk assessment determinations.
1985-11-01
132 M1 .2 * 125 ŕ.4 1.6 MICROCOPY RESOLUTION TEST CHART NATKIOAt BUREAU OF STANDARDS 1963-A - -W -o - 4w " " " lE FILE CUBe -. a II j AFVAL-TR-66... TYPE DEFINITIONS LANGUAGE: C DESCRIPTION: DESCRIPTION TIS FILE ENSURES THAT THE FOLLOWING STANDARD TYPES ARE AVAILABLE: FLOAT - SINGLE PRECISION FLOAT...a 12- ----- le ------- 37+ - -----21+ - -----90+ 3-1176 I*LL A -A S * - S PS 620141100 1 November 1985 61 ICPYDES I I I I I I
Preparation and Evaluation of Herbal Shampoo Powder
Dubey, Sachin; Nema, Neelesh; Nayak, S.
2004-01-01
Two preparations of herbal shampoo powder were formulated using some common traditional drugs used by folk and traditional people of Bundelkhand region (M.P) India, for hair care. The preparations were formulated using bahera, amla, neem tulsi, shikakai henna & brahmi evaluated for organoleptic, powder charecterestics, foam test and physical evaluation. As the selected drugs being used since long time as single drug or in combination, present investigations will further help to establish a standard formulation and evaluation parameters, which will certainly help in the standardization for quality and purity of such type of herbal powder shampoos. PMID:22557149
Bosker, Wendy M; Kuypers, Kim P C; Theunissen, Eef L; Surinx, Anke; Blankespoor, Roos J; Skopp, Gisela; Jeffery, Wayne K; Walls, H Chip; van Leeuwen, Cees J; Ramaekers, Johannes G
2012-10-01
The acute and chronic effects of dronabinol [medicinal Δ(9) -tetrahydrocannabinol (THC)] on actual driving performance and the Standard Field Sobriety Test (SFST) were assessed. It was hypothesized that occasional users would be impaired on these tests and that heavy users would show less impairment due to tolerance. Double-blind, placebo-controlled, randomized, three-way cross-over study. Twelve occasional and 12 heavy cannabis users (14 males/10 females) received single doses of placebo, 10 and 20 mg dronabinol. Standard deviation of lateral position (SDLP; i.e. weaving) is the primary measure of road-tracking control. Time to speed adaptation (TSA) is the primary reaction-time measure in the car-following test. Percentage of impaired individuals on the SFST and subjective high on a visual analogue scale were secondary measures. Superiority tests showed that SDLP (P = 0.008) and TSA (P = 0.011) increased after dronabinol in occasional users. Equivalence tests demonstrated that dronabinol-induced increments in SDLP were bigger than impairment associated with BAC of 0.5 mg/ml in occasional and heavy users, although the magnitude of driving impairment was generally less in heavy users. The SFST did not discriminate between conditions. Levels of subjective high were comparable in occasional and heavy users. Dronabinol (medicinal tetrahydrocannabinol) impairs driving performance in occasional and heavy users in a dose-dependent way, but to a lesser degree in heavy users due possibly to tolerance. The Standard Field Sobriety Test is not sensitive to clinically relevant driving impairment caused by oral tetrahydrocannabinol. © 2012 The Authors. Addiction © 2012 Society for the Study of Addiction.
Yu, Liping; Boulware, David C; Beam, Craig A; Hutton, John C; Wenzlau, Janet M; Greenbaum, Carla J; Bingley, Polly J; Krischer, Jeffrey P; Sosenko, Jay M; Skyler, Jay S; Eisenbarth, George S; Mahon, Jeffrey L
2012-06-01
We assessed diabetes risk associated with zinc transporter-8 antibodies (ZnT8A), islet cell antibodies (ICA), and HLA type and age in relatives of people with type 1 diabetes with the standard biochemical autoantibodies (BAA) to insulin (IAA), GAD65 (GAD65A), and/or insulinoma-associated protein 2 antigen (IA-2A). For this analysis, 2,256 relatives positive for at least one BAA, of whom 142 developed diabetes, were tested for ZnT8A, ICA, and HLA genotype followed by biannual oral glucose tolerance tests. ZnT8A were also tested in 911 randomly chosen antibody-negative relatives. ZnT8A were associated with the other BAA (548 of 2,256 [24.3%] BAA(+) vs. 8 of 911 [0.8%] BAA(-), P < 0.001) and BAA number (177 of 1,683 [10.5%] single-, 221 of 384 [57.6%] double-, and 150 of 189 [79.4%] triple-BAA positivity, P < 0.001). The 4-year diabetes risk was higher in single BAA(+) relatives with ZnT8A than ZnT8A(-) relatives (31 vs. 7%, P < 0.001). In multivariable analysis, age ≤ 20 years (hazard ratio 2.13, P = 0.03), IA-2A (2.15, P = 0.005), IAA (1.73, P = 0.01), ICA (2.37, P = 0.002), and ZnT8A (1.87, P = 0.03) independently predicted diabetes, whereas HLA type (high and moderate vs. low risk) and GAD65A did not (P = 0.81 and 0.86, respectively). In relatives with one standard BAA, ZnT8A identified a subset at higher diabetes risk. ZnT8A predicted diabetes independently of ICA, the standard BAA, age, and HLA type. ZnT8A should be included in type 1 diabetes prediction and prevention studies.
Paap, Kenneth R; Sawi, Oliver
2016-12-01
Studies testing for individual or group differences in executive functioning can be compromised by unknown test-retest reliability. Test-retest reliabilities across an interval of about one week were obtained from performance in the antisaccade, flanker, Simon, and color-shape switching tasks. There is a general trade-off between the greater reliability of single mean RT measures, and the greater process purity of measures based on contrasts between mean RTs in two conditions. The individual differences in RT model recently developed by Miller and Ulrich was used to evaluate the trade-off. Test-retest reliability was statistically significant for 11 of the 12 measures, but was of moderate size, at best, for the difference scores. The test-retest reliabilities for the Simon and flanker interference scores were lower than those for switching costs. Standard practice evaluates the reliability of executive-functioning measures using split-half methods based on data obtained in a single day. Our test-retest measures of reliability are lower, especially for difference scores. These reliability measures must also take into account possible day effects that classical test theory assumes do not occur. Measures based on single mean RTs tend to have acceptable levels of reliability and convergent validity, but are "impure" measures of specific executive functions. The individual differences in RT model shows that the impurity problem is worse than typically assumed. However, the "purer" measures based on difference scores have low convergent validity that is partly caused by deficiencies in test-retest reliability. Copyright © 2016 Elsevier B.V. All rights reserved.
Validation of Dissolution Testing with Biorelevant Media: An OrBiTo Study.
Mann, James; Dressman, Jennifer; Rosenblatt, Karin; Ashworth, Lee; Muenster, Uwe; Frank, Kerstin; Hutchins, Paul; Williams, James; Klumpp, Lukas; Wielockx, Kristina; Berben, Philippe; Augustijns, Patrick; Holm, Rene; Hofmann, Michael; Patel, Sanjaykumar; Beato, Stefania; Ojala, Krista; Tomaszewska, Irena; Bruel, Jean-Luc; Butler, James
2017-12-04
Dissolution testing with biorelevant media has become widespread in the pharmaceutical industry as a means of better understanding how drugs and formulations behave in the gastrointestinal tract. Until now, however, there have been few attempts to gauge the reproducibility of results obtained with these methods. The aim of this study was to determine the interlaboratory reproducibility of biorelevant dissolution testing, using the paddle apparatus (USP 2). Thirteen industrial and three academic laboratories participated in this study. All laboratories were provided with standard protocols for running the tests: dissolution in FaSSGF to simulate release in the stomach, dissolution in a single intestinal medium, FaSSIF, to simulate release in the small intestine, and a "transfer" (two-stage) protocol to simulate the concentration profile when conditions are changed from the gastric to the intestinal environment. The test products chosen were commercially available ibuprofen tablets and zafirlukast tablets. The biorelevant dissolution tests showed a high degree of reproducibility among the participating laboratories, even though several different batches of the commercially available medium preparation powder were used. Likewise, results were almost identicalbetween the commercial biorelevant media and those produced in-house. Comparing results to previous ring studies, including those performed with USP calibrator tablets or commercially available pharmaceutical products in a single medium, the results for the biorelevant studies were highly reproducible on an interlaboratory basis. Interlaboratory reproducibility with the two-stage test was also acceptable, although the variability was somewhat greater than with the single medium tests. Biorelevant dissolution testing is highly reproducible among laboratories and can be relied upon for cross-laboratory comparisons.
Adaptive Set-Based Methods for Association Testing.
Su, Yu-Chen; Gauderman, William James; Berhane, Kiros; Lewinger, Juan Pablo
2016-02-01
With a typical sample size of a few thousand subjects, a single genome-wide association study (GWAS) using traditional one single nucleotide polymorphism (SNP)-at-a-time methods can only detect genetic variants conferring a sizable effect on disease risk. Set-based methods, which analyze sets of SNPs jointly, can detect variants with smaller effects acting within a gene, a pathway, or other biologically relevant sets. Although self-contained set-based methods (those that test sets of variants without regard to variants not in the set) are generally more powerful than competitive set-based approaches (those that rely on comparison of variants in the set of interest with variants not in the set), there is no consensus as to which self-contained methods are best. In particular, several self-contained set tests have been proposed to directly or indirectly "adapt" to the a priori unknown proportion and distribution of effects of the truly associated SNPs in the set, which is a major determinant of their power. A popular adaptive set-based test is the adaptive rank truncated product (ARTP), which seeks the set of SNPs that yields the best-combined evidence of association. We compared the standard ARTP, several ARTP variations we introduced, and other adaptive methods in a comprehensive simulation study to evaluate their performance. We used permutations to assess significance for all the methods and thus provide a level playing field for comparison. We found the standard ARTP test to have the highest power across our simulations followed closely by the global model of random effects (GMRE) and a least absolute shrinkage and selection operator (LASSO)-based test. © 2015 WILEY PERIODICALS, INC.
Geometric accuracy of Landsat-4 and Landsat-5 Thematic Mapper images.
Borgeson, W.T.; Batson, R.M.; Kieffer, H.H.
1985-01-01
The geometric accuracy of the Landsat Thematic Mappers was assessed by a linear least-square comparison of the positions of conspicuous ground features in digital images with their geographic locations as determined from 1:24 000-scale maps. For a Landsat-5 image, the single-dimension standard deviations of the standard digital product, and of this image with additional linear corrections, are 11.2 and 10.3 m, respectively (0.4 pixel). An F-test showed that skew and affine distortion corrections are not significant. At this level of accuracy, the granularity of the digital image and the probable inaccuracy of the 1:24 000 maps began to affect the precision of the comparison. The tested image, even with a moderate accuracy loss in the digital-to-graphic conversion, meets National Horizontal Map Accuracy standards for scales of 1:100 000 and smaller. Two Landsat-4 images, obtained with the Multispectral Scanner on and off, and processed by an interim software system, contain significant skew and affine distortions. -Authors
Single-Case Experimental Designs to Evaluate Novel Technology-Based Health Interventions
Cassidy, Rachel N; Raiff, Bethany R
2013-01-01
Technology-based interventions to promote health are expanding rapidly. Assessing the preliminary efficacy of these interventions can be achieved by employing single-case experiments (sometimes referred to as n-of-1 studies). Although single-case experiments are often misunderstood, they offer excellent solutions to address the challenges associated with testing new technology-based interventions. This paper provides an introduction to single-case techniques and highlights advances in developing and evaluating single-case experiments, which help ensure that treatment outcomes are reliable, replicable, and generalizable. These advances include quality control standards, heuristics to guide visual analysis of time-series data, effect size calculations, and statistical analyses. They also include experimental designs to isolate the active elements in a treatment package and to assess the mechanisms of behavior change. The paper concludes with a discussion of issues related to the generality of findings derived from single-case research and how generality can be established through replication and through analysis of behavioral mechanisms. PMID:23399668
Modular VO oriented Java EE service deployer
NASA Astrophysics Data System (ADS)
Molinaro, Marco; Cepparo, Francesco; De Marco, Marco; Knapic, Cristina; Apollo, Pietro; Smareglia, Riccardo
2014-07-01
The International Virtual Observatory Alliance (IVOA) has produced many standards and recommendations whose aim is to generate an architecture that starts from astrophysical resources, in a general sense, and ends up in deployed consumable services (that are themselves astrophysical resources). Focusing on the Data Access Layer (DAL) system architecture, that these standards define, in the last years a web based application has been developed and maintained at INAF-OATs IA2 (Italian National institute for Astrophysics - Astronomical Observatory of Trieste, Italian center of Astronomical Archives) to try to deploy and manage multiple VO (Virtual Observatory) services in a uniform way: VO-Dance. However a set of criticalities have arisen since when the VO-Dance idea has been produced, plus some major changes underwent and are undergoing at the IVOA DAL layer (and related standards): this urged IA2 to identify a new solution for its own service layer. Keeping on the basic ideas from VO-Dance (simple service configuration, service instantiation at call time and modularity) while switching to different software technologies (e.g. dismissing Java Reflection in favour of Enterprise Java Bean, EJB, based solution), the new solution has been sketched out and tested for feasibility. Here we present the results originating from this test study. The main constraints for this new project come from various fields. A better homogenized solution rising from IVOA DAL standards: for example the new DALI (Data Access Layer Interface) specification that acts as a common interface system for previous and oncoming access protocols. The need for a modular system where each component is based upon a single VO specification allowing services to rely on common capabilities instead of homogenizing them inside service components directly. The search for a scalable system that takes advantage from distributed systems. The constraints find answer in the adopted solutions hereafter sketched. The development of the new system using Java Enterprise technologies can better benefit from existing libraries to build up the single tokens implementing the IVOA standards. Each component can be built from single standards and each deployed service (i.e. service components instantiations) can consume the other components' exposed methods and services without the need of homogenizing them in dedicated libraries. Scalability can be achieved in an easier way by deploying components or sets of services on a distributed environment and using JNDI (Java Naming and Directory Interface) and RMI (Remote Method Invocation) technologies. Single service configuration will not be significantly different from the VO-Dance solution given that Java class instantiation that benefited from Java Reflection will only be moved to Java EJB pooling (and not, e.g. embedded in bundles for subsequent deployment).
Review of ingot niobium as a material for superconducting radiofrequency accelerating cavities
NASA Astrophysics Data System (ADS)
Kneisel, P.; Ciovati, G.; Dhakal, P.; Saito, K.; Singer, W.; Singer, X.; Myneni, G. R.
2015-02-01
As a result of collaboration between Jefferson Lab and niobium manufacturer Companhia Brasileira de Metalurgia e Mineração (CBMM), ingot niobium was explored as a possible material for superconducting radiofrequency (SRF) cavity fabrication. The first single cell cavity from large-grain high purity niobium was fabricated and successfully tested at Jefferson Lab in 2004. This work triggered research activities in other SRF laboratories around the world. Large-grain (LG) niobium became not only an interesting alternative material for cavity builders, but also material scientists and surface scientists were eager to participate in the development of this technology. Many single cell cavities made from material of different suppliers have been tested successfully and several multi-cell cavities have shown performances comparable to the best cavities made from standard fine-grain niobium. Several 9-cell cavities fabricated by Research Instruments and tested at DESY exceeded the best performing fine grain cavities with a record accelerating gradient of Eacc=45.6 MV/m. The quality factor of those cavities was also higher than that of fine-grain (FG) cavities processed with the same methods. Such performance levels push the state-of-the art of SRF technology and are of great interest for future accelerators. This contribution reviews the development of ingot niobium technology and highlights some of the differences compared to standard FG material and opportunities for further developments.
Review of ingot niobium as a material for superconducting radiofrequency accelerating cavities
Kneisel, P.; Ciovati, G.; Dhakal, P.; ...
2014-12-01
As a result of collaboration between Jefferson Lab and niobium manufacturer Companhia Brasileira de Metalurgia e Mineração (CBMM), ingot niobium was explored as a possible material for superconducting radiofrequency (SRF) cavity fabrication. The first single cell cavity from large-grain high purity niobium was fabricated and successfully tested at Jefferson Lab in 2004. This work triggered research activities in other SRF laboratories around the world. The large-grain (LG) niobium became not only an interesting alternative material for cavity builders, but also material scientists and surface scientists were eager to participate in the development of this technology. Many single cell cavities mademore » from material of different suppliers have been tested successfully and several multi-cell cavities have shown performances comparable to the best cavities made from standard fine-grain niobium. Several 9-cell cavities fabricated by Research Instruments and tested at DESY exceeded the best performing fine grain cavities with a record accelerating gradient of E acc=45.6 MV/m. The quality factor of those cavities was also higher than that of fine-grain (FG) cavities processed with the same methods. Such performance levels push the state-of-the art of SRF technology and are of great interest for future accelerators. This contribution reviews the development of ingot niobium technology and highlights some of the differences compared to standard FG material and opportunities for further developments.« less
Yoshida, Yosuke; Ikuno, Koki; Shomoto, Koji
2017-12-01
To compare sensory-level neuromuscular electrical stimulation (NMES) and conventional motor-level NMES in patients after total knee arthroplasty. Prospective randomized single-blind trial. Hospital total arthroplasty center: inpatients. Patients with osteoarthritis (N=66; mean age, 73.5±6.3y; 85% women) were randomized to receive either sensory-level NMES applied to the quadriceps (the sensory-level NMES group), motor-level NMES (the motor-level NMES group), or no stimulation (the control group) in addition to a standard rehabilitation program. Each type of NMES was applied in 45-minute sessions, 5d/wk, for 2 weeks. Data for the quadriceps maximum voluntary isometric contraction, the leg skeletal muscle mass determined using multiple-frequency bioelectrical impedance analysis, the timed Up and Go test, the 2-minute walk test, the visual analog scale, and the range of motion of the knee were measured preoperatively and at 2 and 4 weeks after total knee arthroplasty. The motor-level NMES (P=.001) and sensory-level NMES (P=.028) groups achieved better maximum voluntary isometric contraction results than did the control group. The motor-level NMES (P=.003) and sensory-level NMES (P=.046) groups achieved better 2-minute walk test results than did the control group. Some patients in the motor-level NMES group dropped out of the experiment because of discomfort. Motor-level NMES significantly improved muscle strength and functional performance more than did the standard program alone. Motor-level NMES was uncomfortable for some patients. Sensory-level NMES was comfortable and improved muscle strength and functional performance more than did the standard program alone. Copyright © 2017 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Orientation dependence of the stress rupture properties of Nickel-base superalloy single crystals
NASA Technical Reports Server (NTRS)
Mackay, R. A.
1981-01-01
The influence of orientation of the stress rupture behavior of Mar-M247 single crystals was studied. Stress rupture tests were performed at 724 MPa and 774 C where the effect of anisotropy is prominent. The mechanical behavior of the single crystals was rationalized on the basis of the Schmid factors for the operative slip systems and the lattice rotations which the crystals underwent during deformation. The stress rupture lives were found to be greatly influenced by the lattice rotations required to produce intersecting slip, because steady-state creep does not begin until after the onset of intersecting slip. Crystals which required large rotations to become oriented for intersecting slip exhibited a large primary creep strain, a large effective stress level at the onset of steady-state creep, and consequently a short stress rupture life. A unified analysis was attained for the stress rupture behavior of the Mar-M247 single crystals tested in this study at 774 C and that of the Mar-M200 single crystals tested in a prior study at 760 C. In this analysis, the standard 001-011-111 stereographic triangle was divided into several regions of crystallographic orientation which were rank ordered according to stress rupture life for this temperature regime. This plot indicates that those crystals having orientations within about 25 deg of the 001 exhibited significantly longer lives when their orientations were closer to the 001-011 boundary of the stereographic triangle than to the 001-111 boundary.
Equations of state for detonation products of high energy PBX explosives
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, E. L.; Helm, F. H.; Finger, M.
1977-08-01
It has become apparent that the accumulated changes in the analysis of cylinder test data, in the material specifications, and in the hydrodynamic code simulation of the cylinder test necessitated an update of the detonation product EOS description for explosives in common use at LLL. The explosives reviewed are PBX-9404-3, LX-04-1, LX-10-1, LX-14-0 and LX-09-1. In order to maintain the proper relation of predicted performance of these standard explosives, they have been revised as a single set.
The Cold Dark Matter Search test stand warm electronics card
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hines, Bruce; /Colorado U., Denver; Hansen, Sten
A card which does the signal processing for four SQUID amplifiers and two charge sensitive channels is described. The card performs the same functions as is presently done with two custom 9U x 280mm Eurocard modules, a commercial multi-channel VME digitizer, a PCI to GPIB interface, a PCI to VME interface and a custom built linear power supply. By integrating these functions onto a single card and using the power over Ethernet standard, the infrastructure requirements for instrumenting a Cold Dark Matter Search (CDMS) detector test stand are significantly reduced.
X-43A Rudder Spindle Fatigue Life Estimate and Testing
NASA Technical Reports Server (NTRS)
Glaessgen, Edward H.; Dawicke, David S.; Johnston, William M.; James, Mark A.; Simonsen, Micah; Mason, Brian H.
2005-01-01
Fatigue life analyses were performed using a standard strain-life approach and a linear cumulative damage parameter to assess the effect of a single accidental overload on the fatigue life of the Haynes 230 nickel-base superalloy X-43A rudder spindle. Because of a limited amount of information available about the Haynes 230 material, a series of tests were conducted to replicate the overload and in-service conditions for the spindle and corroborate the analysis. Both the analytical and experimental results suggest that the spindle will survive the anticipated flight loads.
Moya-Angeler, Joaquín; Vaquero, Javier; Forriol, Francisco
2017-06-01
The purpose of this study was to evaluate the functional status prior to and at different times after anterior cruciate ligament reconstruction (ACLR), and to analyze the changes in the kinetic patterns of the involved and uninvolved lower limb during gait, sprint and three hop tests. Seventy-four male patients with an ACL injury were included in the study. All patients performed a standardized kinetic protocol including gait, sprint and three hop tests (single-leg hop, drop vertical jump and vertical jump tests), preoperatively and at 3, 6, and 12 months after ACLR with a semitendinosus gracilis tendon autograft. Measurements were performed with two force plates. The lower limb symmetry index (LSI) was calculated to determine whether a side-to-side leg difference was classified as normal (LSI >90%) or abnormal (LSI <90%). The LSI presented high values (>90%) at almost all times before and after ACLR in gait, sprint and single-leg hop tests (p < 0.005), with a tendency to increase postoperatively. A lower LSI was observed (<90%) in tests where both extremities were tested simultaneously, such as the drop vertical jump and vertical hop tests (p < 0.05). We observed a tendency to increase symmetry restoration in the kinetics of the involved and uninvolved limb up to twelve months after ACLR, especially in those tests, in which, both limbs were tested individually (gait analysis, sprint and single-leg hop tests). Therefore, the isolation of the involved and uninvolved limb seems to be a critical component in the functional rehabilitation and evaluation of patients before and after ACLR. level III.
Alternative Confidence Interval Methods Used in the Diagnostic Accuracy Studies
Gülhan, Orekıcı Temel
2016-01-01
Background/Aim. It is necessary to decide whether the newly improved methods are better than the standard or reference test or not. To decide whether the new diagnostics test is better than the gold standard test/imperfect standard test, the differences of estimated sensitivity/specificity are calculated with the help of information obtained from samples. However, to generalize this value to the population, it should be given with the confidence intervals. The aim of this study is to evaluate the confidence interval methods developed for the differences between the two dependent sensitivity/specificity values on a clinical application. Materials and Methods. In this study, confidence interval methods like Asymptotic Intervals, Conditional Intervals, Unconditional Interval, Score Intervals, and Nonparametric Methods Based on Relative Effects Intervals are used. Besides, as clinical application, data used in diagnostics study by Dickel et al. (2010) has been taken as a sample. Results. The results belonging to the alternative confidence interval methods for Nickel Sulfate, Potassium Dichromate, and Lanolin Alcohol are given as a table. Conclusion. While preferring the confidence interval methods, the researchers have to consider whether the case to be compared is single ratio or dependent binary ratio differences, the correlation coefficient between the rates in two dependent ratios and the sample sizes. PMID:27478491
Alternative Confidence Interval Methods Used in the Diagnostic Accuracy Studies.
Erdoğan, Semra; Gülhan, Orekıcı Temel
2016-01-01
Background/Aim. It is necessary to decide whether the newly improved methods are better than the standard or reference test or not. To decide whether the new diagnostics test is better than the gold standard test/imperfect standard test, the differences of estimated sensitivity/specificity are calculated with the help of information obtained from samples. However, to generalize this value to the population, it should be given with the confidence intervals. The aim of this study is to evaluate the confidence interval methods developed for the differences between the two dependent sensitivity/specificity values on a clinical application. Materials and Methods. In this study, confidence interval methods like Asymptotic Intervals, Conditional Intervals, Unconditional Interval, Score Intervals, and Nonparametric Methods Based on Relative Effects Intervals are used. Besides, as clinical application, data used in diagnostics study by Dickel et al. (2010) has been taken as a sample. Results. The results belonging to the alternative confidence interval methods for Nickel Sulfate, Potassium Dichromate, and Lanolin Alcohol are given as a table. Conclusion. While preferring the confidence interval methods, the researchers have to consider whether the case to be compared is single ratio or dependent binary ratio differences, the correlation coefficient between the rates in two dependent ratios and the sample sizes.
Gandolfini, I; Buzio, C; Zanelli, P; Palmisano, A; Cremaschi, E; Vaglio, A; Piotti, G; Melfa, L; La Manna, G; Feliciangeli, G; Cappuccilli, M; Scolari, M P; Capelli, I; Panicali, L; Baraldi, O; Stefoni, S; Buscaroli, A; Ridolfi, L; D'Errico, A; Cappelli, G; Bonucchi, D; Rubbiani, E; Albertazzi, A; Mehrotra, A; Cravedi, P; Maggiore, U
2014-11-01
Pretransplant donor biopsy (PTDB)-based marginal donor allocation systems to single or dual renal transplantation could increase the use of organs with Kidney Donor Profile Index (KDPI) in the highest range (e.g. >80 or >90), whose discard rate approximates 50% in the United States. To test this hypothesis, we retrospectively calculated the KDPI and analyzed the outcomes of 442 marginal kidney transplants (340 single transplants: 278 with a PTDB Remuzzi score<4 [median KDPI: 87; interquartile range (IQR): 78-94] and 62 with a score=4 [median KDPI: 87; IQR: 76-93]; 102 dual transplants [median KDPI: 93; IQR: 86-96]) and 248 single standard transplant controls (median KDPI: 36; IQR: 18-51). PTDB-based allocation of marginal grafts led to a limited discard rate of 15% for kidneys with KDPI of 80-90 and of 37% for kidneys with a KDPI of 91-100. Although 1-year estimated GFRs were significantly lower in recipients of marginal kidneys (-9.3, -17.9 and -18.8 mL/min, for dual transplants, single kidneys with PTDB score<4 and =4, respectively; p<0.001), graft survival (median follow-up 3.3 years) was similar between marginal and standard kidney transplants (hazard ratio: 1.20 [95% confidence interval: 0.80-1.79; p=0.38]). In conclusion, PTDB-based allocation allows the safe transplantation of kidneys with KDPI in the highest range that may otherwise be discarded. © Copyright 2014 The American Society of Transplantation and the American Society of Transplant Surgeons.
Managing Risk to Ensure a Successful Cassini/Huygens Saturn Orbit Insertion (SOI)
NASA Technical Reports Server (NTRS)
Witkowski, Mona M.; Huh, Shin M.; Burt, John B.; Webster, Julie L.
2004-01-01
I. Design: a) S/C designed to be largely single fault tolerant; b) Operate in flight demonstrated envelope, with margin; and c) Strict compliance with requirements & flight rules. II. Test: a) Baseline, fault & stress testing using flight system testbeds (H/W & S/W); b) In-flight checkout & demos to remove first time events. III. Failure Analysis: a) Critical event driven fault tree analysis; b) Risk mitigation & development of contingencies. IV) Residual Risks: a) Accepted pre-launch waivers to Single Point Failures; b) Unavoidable risks (e.g. natural disaster). V) Mission Assurance: a) Strict process for characterization of variances (ISAs, PFRs & Waivers; b) Full time Mission Assurance Manager reports to Program Manager: 1) Independent assessment of compliance with institutional standards; 2) Oversight & risk assessment of ISAs, PFRs & Waivers etc.; and 3) Risk Management Process facilitator.
Shuttle launched flight tests - Supporting technology for planetary entry missions
NASA Technical Reports Server (NTRS)
Vetter, H. C.; Mcneilly, W. R.; Siemers, P. M., III; Nachtsheim, P. R.
1975-01-01
The feasibility of conducting Space Shuttle-launched earth entry flight tests to enhance the technology base for second generation planetary entry missions is examined. Outer planet entry environments are reviewed, translated into earth entry requirements and used to establish entry test system design and cost characteristics. Entry speeds up to those needed to simulate radiative heating levels of more than 30 kW/sq cm are shown to be possible. A standardized recoverable test bed concept is described that is capable of accommodating a wide range of entry technology experiments. The economic advantage of shared Shuttle launches are shown to be achievable through a test system configured to the volume constraints of a single Spacelab pallet using existing propulsion components.
Comparison of different measurement methods for transmittance haze
NASA Astrophysics Data System (ADS)
Yu, Hsueh-Ling; Hsaio, Chin-Chai
2009-08-01
Transmittance haze is increasingly important to the LCD and solar cell industry. Most commercial haze measurement instruments are designed according to the method recommended in the documentary standards like ASTM D 1003 (ASTM 2003 Standard Test Method for Haze and Luminous Transmittance of Transparent Plastics), JIS K 7361 (JIS 1997 Plastics—Determination of the Total Luminous Transmittance of Transparent Materials—Part 1: Single Beam Instrument) and ISO 14782 (ISO 1997 Plastics—Determination of Haze of Transparent Materials). To improve the measurement accuracy of the current standards, a new apparatus was designed by the Center for Measurement Standards (Yu et al 2006 Meas. Sci. Technol. 17 N29-36). Besides the methods mentioned above, a double-beam method is used in the design of some instruments. There are discrepancies between the various methods. But no matter which method is used, a white standard is always needed. This paper compares the measurement results from different methods, presents the effect of the white standard, and analyses the measurement uncertainty.
Contribution to Estimating Bearing Capacity of Pile in Clayey Soils
NASA Astrophysics Data System (ADS)
Drusa, Marián; Gago, Filip; Vlček, Jozef
2016-12-01
The estimation of real geotechnical parameters is key factor for safe and economic design of geotechnical structures. One of these are pile foundations, which require proper design and evaluation due to accessing more deep foundation soil and because remediation work of not bearable piles or broken piles is a crucial operation. For this reason, geotechnical field testing like cone penetration test (CPT), standard penetration (SPT) or dynamic penetration test (DP) are realized in order to receive continuous information about soil strata. Comparing with rotary core drilling type of survey with sampling, these methods are more progressive. From engineering geologist point of view, it is more important to know geological characterization of locality but geotechnical engineers have more interest above the real geotechnical parameters of foundation soils. The role of engineering geologist cannot be underestimated because important geological processes in origin or during history can explain behaviour of a geological environment. In effort to streamline the survey, investigation by penetration tests is done as it is able to provide enough information for designers. This paper deals with actual trends in pile foundation design; because there are no new standards and usable standards are very old. Estimation of the bearing capacity of a single pile can be demonstrated on the example of determination of the cone factor Nk from CPT testing. Then results were compared with other common methods.
The development of a site-specific water-quality standard for copper
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sinclair, R.M.
This dissertation proposes to determine, for one toxic chemical, copper, if the Federal water quality standard and the state interpretation of that standard are appropriate for the Duck River, some 50 miles south of Nashville, Tennessee. This involved conducting toxicity tests in Duck River water, and the use of the computer metal speciation program MINTEQA1 to predict instream impact. The speciation model chosen for the determination of chemical equilibria in this study was MINTEQA1. To test the validity of the MINTEQA1 speciation model, water chemistry from the Duck River was entered into the model. At the typical site pH ofmore » 7.8, 55.7% of the copper is bound as Cu(OH){sub 2}, 29.8% is bound as copper humate, and 12.7% is found as CuCO{sub 3}. Of extreme importance to the toxicity of copper in the site water is the complete absence of the most toxic species, ionic copper. The test species were the brook silversides minnow (Labidesthes sicculus), mosquitofish (Gambusia affinis), caddisfly larvae (Cheumatopsyche sp.), fathead minnow (Pimephales promelas), geniculate river snail (Lithasia geniculata), sunfish (Lepomis sp.), and the amphipod (Hyalella azeca). The test concentrations were confirmed by atomic absorption spectroscopy on selected concentrations. The caddisfly larvae was the single most tolerant species observed during this study, while the amphipod and snail were the two most sensitive species tested.« less
Synthesizing Single-Case Research to Identify Evidence-Based Practices: Some Brief Reflections
ERIC Educational Resources Information Center
Horner, Robert H.; Kratochwill, Thomas R.
2012-01-01
The purposes of this paper are to (a) propose an operational standard for defining a "practice," (b) encourage development of professional standards for visual and statistical analysis of single-case research, and (c) propose a standard for using single-case research results to identify practices that are "evidence-based." These topics are not new…
Alternative magnetic flux leakage modalities for pipeline inspection
DOE Office of Scientific and Technical Information (OSTI.GOV)
Katragadda, G.; Lord, W.; Sun, Y.S.
1996-05-01
Increasing quality consciousness is placing higher demands on the accuracy and reliability of inspection systems used in defect detection and characterization. Nondestructive testing techniques often rely on using multi-transducer approaches to obtain greater defect sensitivity. This paper investigates the possibility of taking advantage of alternative modalities associated with the standard magnetic flux leakage tool to obtain additional defect information, while still using a single excitation source.
ERIC Educational Resources Information Center
O'Neal, Angeline N.
2013-01-01
In response to numerous mandates in the field of education, schools have found it imperative to ensure that teachers are incorporating effective instructional methods which meet the diverse needs of student populations within a single classroom. The co-teaching model of instruction is just one way educators have chosen to lead classroom…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Assoufid, Lahsen; Shi, Xianbo; Marathe, Shashidhara
We developed a portable X-ray grating interferometer setup as a standard tool for testing optics at the Advanced Photon Source (APS) beamline 1-BM. The interferometer can be operated in phase-stepping, Moiré, or single-grating harmonic imaging mode with 1-D or 2-D gratings. All of the interferometer motions are motorized; hence, it is much easier and quicker to switch between the different modes of operation. A novel aspect of this new instrument is its designed portability. While the setup is designed to be primarily used as a standard tool for testing optics at 1-BM, it could be potentially deployed at other APSmore » beamlines for beam coherence and wavefront characterization or imaging. The design of the interferometer system is described in detail and coherence measurements obtained at the APS 34-ID-E beamline are presented. The coherence was probed in two directions using a 2-D checkerboard, a linear, and a circular grating at X-ray energies of 8 keV, 11 keV, and 18 keV.« less
Thomas, Pious; Sekhar, Aparna C; Upreti, Reshmi; Mujawar, Mohammad M; Pasha, Sadiq S
2015-12-01
We propose a simple technique for bacterial and yeast cfu estimations from diverse samples with no prior idea of viable counts, designated as single plate-serial dilution spotting (SP-SDS) with the prime recommendation of sample anchoring (10 0 stocks). For pure cultures, serial dilutions were prepared from 0.1 OD (10 0 ) stock and 20 μl aliquots of six dilutions (10 1 -10 6 ) were applied as 10-15 micro-drops in six sectors over agar-gelled medium in 9-cm plates. For liquid samples 10 0 -10 5 dilutions, and for colloidal suspensions and solid samples (10% w/v), 10 1 -10 6 dilutions were used. Following incubation, at least one dilution level yielded 6-60 cfu per sector comparable to the standard method involving 100 μl samples. Tested on diverse bacteria, composite samples and Saccharomyces cerevisiae , SP-SDS offered wider applicability over alternative methods like drop-plating and track-dilution for cfu estimation, single colony isolation and culture purity testing, particularly suiting low resource settings.
Gan, W; Zhou, X; Yang, H; Chen, H; Qiao, J; Khan, S H; Yang, L; Yin, X; Zhao, D
2013-08-03
The infection status of cattle for bovine tuberculosis (bTB) was determined by real-time PCR, comparing the levels of IFN-γ mRNA in blood cultures stimulated with either bovine or avian tuberculin with non-stimulated control (phosphate buffer saline, PBS) blood culture. Totally, 137 cattle were tested to validate the assay, in which 54 were IFN-γ real-time quantitative PCR (RT-qPCR) positive, while the remaining 83 were found negative. Meanwhile, the IFN-γ ELISA test was carried out using the Bovigam IFN-γ detection ELISA kit and these results were used as a standard. The results of the single intradermal tuberculin tests (SIDT) and IFN-γ RT-qPCR tests were compared and revealed that the RT-qPCR correlated better with the ELISA and its accuracy was higher than SIDT. This indicates the RT-qPCR is a useful diagnostic method for bTB in cattle. However, several limitations remain for our approach, such as lack of a TB lesions or postmortem test results as a gold standard. Further improvements should be made in the future to increase accuracy of diagnosis of bTB in cattle.
The effect of 'standard drink' labelling on the ability of drinkers to pour a 'standard drink'.
Stockwell, T; Blaze-Temple, D; Walker, C
1991-03-01
Australia's National Health Policy on Alcohol has recommended that beverage containers be labelled so that alcohol content is 'readily understandable by the public'. Health promotion to increase the responsible use of alcohol now relies extensively on the concept of a standard drink--usually defined as 10 g of ethyl alcohol. Numerous difficulties confront a drinker who wishes to apply the standard drink system to monitor alcohol intake. This report describes a series of experimental tests of the proposal that these difficulties are minimised if alcohol containers have their alcohol content indicated in terms of standard drinks in addition to the usual percentage alcohol by volume method. Subjects were drinkers recruited from a Perth shopping mall and were tested only on beverage types they had consumed within the previous week. They were required to pour what they judged to be a single standard drink from a 750 ml bottle of either wine or beer. Beer drinkers achieved greater accuracy in this task when the bottles had standard drink labels, even when the glass size and beverage strength were varied. Wine drinkers had equal difficulty with this task whether standard drink or percentage labels were used. The addition of a 'ladder' up the side of a wine bottle with graduations in standard drinks would be necessary for wine drinkers to achieve a high level of accuracy. We conclude that labelling drink containers with their alcohol content in terms of standard drinks would better equip all drinkers to follow the advice of health educators.
NASA Astrophysics Data System (ADS)
Rock, N. M. S.
ROBUST calculates 53 statistics, plus significance levels for 6 hypothesis tests, on each of up to 52 variables. These together allow the following properties of the data distribution for each variable to be examined in detail: (1) Location. Three means (arithmetic, geometric, harmonic) are calculated, together with the midrange and 19 high-performance robust L-, M-, and W-estimates of location (combined, adaptive, trimmed estimates, etc.) (2) Scale. The standard deviation is calculated along with the H-spread/2 (≈ semi-interquartile range), the mean and median absolute deviations from both mean and median, and a biweight scale estimator. The 23 location and 6 scale estimators programmed cover all possible degrees of robustness. (3) Normality: Distributions are tested against the null hypothesis that they are normal, using the 3rd (√ h1) and 4th ( b 2) moments, Geary's ratio (mean deviation/standard deviation), Filliben's probability plot correlation coefficient, and a more robust test based on the biweight scale estimator. These statistics collectively are sensitive to most usual departures from normality. (4) Presence of outliers. The maximum and minimum values are assessed individually or jointly using Grubbs' maximum Studentized residuals, Harvey's and Dixon's criteria, and the Studentized range. For a single input variable, outliers can be either winsorized or eliminated and all estimates recalculated iteratively as desired. The following data-transformations also can be applied: linear, log 10, generalized Box Cox power (including log, reciprocal, and square root), exponentiation, and standardization. For more than one variable, all results are tabulated in a single run of ROBUST. Further options are incorporated to assess ratios (of two variables) as well as discrete variables, and be concerned with missing data. Cumulative S-plots (for assessing normality graphically) also can be generated. The mutual consistency or inconsistency of all these measures helps to detect errors in data as well as to assess data-distributions themselves.
Odor measurements according to EN 13725: A statistical analysis of variance components
NASA Astrophysics Data System (ADS)
Klarenbeek, Johannes V.; Ogink, Nico W. M.; van der Voet, Hilko
2014-04-01
In Europe, dynamic olfactometry, as described by the European standard EN 13725, has become the preferred method for evaluating odor emissions emanating from industrial and agricultural sources. Key elements of this standard are the quality criteria for trueness and precision (repeatability). Both are linked to standard values of n-butanol in nitrogen. It is assumed in this standard that whenever a laboratory complies with the overall sensory quality criteria for n-butanol, the quality level is transferable to other, environmental, odors. Although olfactometry is well established, little has been done to investigate inter laboratory variance (reproducibility). Therefore, the objective of this study was to estimate the reproducibility of odor laboratories complying with EN 13725 as well as to investigate the transferability of n-butanol quality criteria to other odorants. Based upon the statistical analysis of 412 odor measurements on 33 sources, distributed in 10 proficiency tests, it was established that laboratory, panel and panel session are components of variance that significantly differ between n-butanol and other odorants (α = 0.05). This finding does not support the transferability of the quality criteria, as determined on n-butanol, to other odorants and as such is a cause for reconsideration of the present single reference odorant as laid down in EN 13725. In case of non-butanol odorants, repeatability standard deviation (sr) and reproducibility standard deviation (sR) were calculated to be 0.108 and 0.282 respectively (log base-10). The latter implies that the difference between two consecutive single measurements, performed on the same testing material by two or more laboratories under reproducibility conditions, will not be larger than a factor 6.3 in 95% of cases. As far as n-butanol odorants are concerned, it was found that the present repeatability standard deviation (sr = 0.108) compares favorably to that of EN 13725 (sr = 0.172). It is therefore suggested that the repeatability limit (r), as laid down in EN 13725, can be reduced from r ≤ 0.477 to r ≤ 0.31.
Can we improve clinical prediction of at-risk older drivers?
Bowers, Alex R.; Anastasio, R. Julius; Sheldon, Sarah S.; O’Connor, Margaret G.; Hollis, Ann M.; Howe, Piers D.; Horowitz, Todd S.
2013-01-01
Objectives To conduct a pilot study to evaluate the predictive value of the Montreal Cognitive Assessment test (MoCA) and a brief test of multiple object tracking (MOT) relative to other tests of cognition and attention in identifying at-risk older drivers, and to determine which combination of tests provided the best overall prediction. Methods Forty-seven currently-licensed drivers (58 to 95 years), primarily from a clinical driving evaluation program, participated. Their performance was measured on: (1) a screening test battery, comprising MoCA, MOT, MiniMental State Examination (MMSE), Trail-Making Test, visual acuity, contrast sensitivity, and Useful Field of View (UFOV); and (2) a standardized road test. Results Eighteen participants were rated at-risk on the road test. UFOV subtest 2 was the best single predictor with an area under the curve (AUC) of .84. Neither MoCA nor MOT was a better predictor of the at-risk outcome than either MMSE or UFOV, respectively. The best four-test combination (MMSE, UFOV subtest 2, visual acuity and contrast sensitivity) was able to identify at-risk drivers with 95% specificity and 80% sensitivity (.91 AUC). Conclusions Although the best four-test combination was much better than a single test in identifying at-risk drivers, there is still much work to do in this field to establish test batteries that have both high sensitivity and specificity. PMID:23954688
Matta, Ragai E; Schmitt, Johannes; Wichmann, Manfred; Holst, Stefan
2012-10-01
Techniques currently applied to determine the marginal accuracy of dental crown restorations yield inadequate information. This investigation aimed to test a new virtual approach for determining the precision of fit of single-crown copings. Zirconia single crown copings were manufactured on 10 gypsum, single-tooth master casts with two different established computer-aided design/computer-assisted manufacture (CAD/CAM) systems (groups A and B). After cementation, the circumferential fit was assessed with an industrial noncontact scanner and virtual 3D analysis, following a triple-scan protocol. Marginal fit was determined by virtual sectioning; each abutment-coping complex was digitally sliced in 360 vertical sections (1 degree per section). Standardized measurement distances for analyzing the marginal fit (z, xy, xyz) were selected, and a crosshair alignment was utilized to determine whether crowns were horizontally and/or vertically too large or small. The Mann-Whitney test was applied to test for differences between groups. Significant differences in the xy direction (P = .008) were measured between groups. Group A showed a greater number of horizontally overextended margins and a higher frequency of xy distances greater than 150 Μm, in addition to a tendency for excessive z distances (P = .095). The mean marginal gap values were clinically acceptable in the present investigation; however, a full circumferential analysis revealed significant differences in marginal coping quality.
Single-tier testing with the C6 peptide ELISA kit compared with two-tier testing for Lyme disease.
Wormser, Gary P; Schriefer, Martin; Aguero-Rosenfeld, Maria E; Levin, Andrew; Steere, Allen C; Nadelman, Robert B; Nowakowski, John; Marques, Adriana; Johnson, Barbara J B; Dumler, J Stephen
2013-01-01
For the diagnosis of Lyme disease, the 2-tier serologic testing protocol for Lyme disease has a number of shortcomings including low sensitivity in early disease; increased cost, time, and labor; and subjectivity in the interpretation of immunoblots. In this study, the diagnostic accuracy of a single-tier commercial C6 ELISA kit was compared with 2-tier testing. The results showed that the C6 ELISA was significantly more sensitive than 2-tier testing with sensitivities of 66.5% (95% confidence interval [CI] 61.7-71.1) and 35.2% (95% CI 30.6-40.1), respectively (P < 0.001) in 403 sera from patients with erythema migrans. The C6 ELISA had sensitivity statistically comparable to 2-tier testing in sera from Lyme disease patients with early neurologic manifestations (88.6% versus 77.3%, P = 0.13) or arthritis (98.3% versus 95.6%, P = 0.38). The specificities of C6 ELISA and 2-tier testing in over 2200 blood donors, patients with other conditions, and Lyme disease vaccine recipients were found to be 98.9% and 99.5%, respectively (P < 0.05, 95% CI surrounding the 0.6 percentage point difference of 0.04 to 1.15). In conclusion, using a reference standard of 2-tier testing, the C6 ELISA as a single-step serodiagnostic test provided increased sensitivity in early Lyme disease with comparable sensitivity in later manifestations of Lyme disease. The C6 ELISA had slightly decreased specificity. Future studies should evaluate the performance of the C6 ELISA compared with 2-tier testing in routine clinical practice. Copyright © 2013 Elsevier Inc. All rights reserved.
Effects of listening to pleasant music on chronic unilateral neglect: a single-subject study.
Tsai, Pei-Luen; Chen, Mei-Ching; Huang, Yu-Ting; Lin, Keh-Chung
2013-01-01
Recent studies suggest that the positive emotion induced by pleasant music may improve cognitive functions. We used the single-subject design to study whether listening to preferred music may reduce unilateral neglect in two participants with post-stroke neglect. These participants were instructed to listen to their preferred music every day for 5 weeks, followed by 2 weeks of follow-up assessment. Outcome measures involved the Star Cancellation Test, the Line Bisection Test, and the visual exploration task. A combination of visual analysis and the two-standard-deviation band method was used for data analysis. Both participants showed significant intervention-related improvements on all outcome measures except the Line Bisection Test, on which one participant showed no improvement. The therapeutic effects were maintained during the follow-up phase. The findings suggest that positive emotion, evoked by preferred music, may be used to ameliorate unilateral neglect. Further research using controlled trials is warranted to validate the findings.
User manual for SPLASH (Single Panel Lamp and Shroud Helper).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Larsen, Marvin Elwood
2006-02-01
The radiant heat test facility develops test sets providing well-characterized thermal environments, often representing fires. Many of the components and procedures have become standardized to such an extent that the development of a specialized design tool to determine optimal configurations for radiant heat experiments was appropriate. SPLASH (Single Panel Lamp and Shroud Helper) is that tool. SPLASH is implemented as a user-friendly, Windows-based program that allows a designer to describe a test setup in terms of parameters such as number of lamps, power, position, and separation distance. This document is a user manual for that software. Any incidental descriptions ofmore » theory are only for the purpose of defining the model inputs. The theory for the underlying model is described in SAND2005-2947 (Ref. [1]). SPLASH provides a graphical user interface to define lamp panel and shroud designs parametrically, solves the resulting radiation enclosure problem for up to 2500 surfaces, and provides post-processing to facilitate understanding and documentation of analyzed designs.« less
Passively aligned multichannel fiber-pigtailing of planar integrated optical waveguides
NASA Astrophysics Data System (ADS)
Kremmel, Johannes; Lamprecht, Tobias; Crameri, Nino; Michler, Markus
2017-02-01
A silicon device to simplify the coupling of multiple single-mode fibers to embedded single-mode waveguides has been developed. The silicon device features alignment structures that enable a passive alignment of fibers to integrated waveguides. For passive alignment, precisely machined V-grooves on a silicon device are used and the planar lightwave circuit board features high-precision structures acting as a mechanical stop. The approach has been tested for up to eight fiber-to-waveguide connections. The alignment approach, the design, and the fabrication of the silicon device as well as the assembly process are presented. The characterization of the fiber-to-waveguide link reveals total coupling losses of (0.45±0.20 dB) per coupling interface, which is significantly lower than the values reported in earlier works. Subsequent climate tests reveal that the coupling losses remain stable during thermal cycling but increases significantly during an 85°C/85 Rh-test. All applied fabrication and bonding steps have been performed using standard MOEMS fabrication and packaging processes.
Physical employment standards for U.K. fire and rescue service personnel.
Blacker, S D; Rayson, M P; Wilkinson, D M; Carter, J M; Nevill, A M; Richmond, V L
2016-01-01
Evidence-based physical employment standards are vital for recruiting, training and maintaining the operational effectiveness of personnel in physically demanding occupations. (i) Develop criterion tests for in-service physical assessment, which simulate the role-related physical demands of UK fire and rescue service (UK FRS) personnel. (ii) Develop practical physical selection tests for FRS applicants. (iii) Evaluate the validity of the selection tests to predict criterion test performance. Stage 1: we conducted a physical demands analysis involving seven workshops and an expert panel to document the key physical tasks required of UK FRS personnel and to develop 'criterion' and 'selection' tests. Stage 2: we measured the performance of 137 trainee and 50 trained UK FRS personnel on selection, criterion and 'field' measures of aerobic power, strength and body size. Statistical models were developed to predict criterion test performance. Stage 3: matter experts derived minimum performance standards. We developed single person simulations of the key physical tasks required of UK FRS personnel as criterion and selection tests (rural fire, domestic fire, ladder lift, ladder extension, ladder climb, pump assembly, enclosed space search). Selection tests were marginally stronger predictors of criterion test performance (r = 0.88-0.94, 95% Limits of Agreement [LoA] 7.6-14.0%) than field test scores (r = 0.84-0.94, 95% LoA 8.0-19.8%) and offered greater face and content validity and more practical implementation. This study outlines the development of role-related, gender-free physical employment tests for the UK FRS, which conform to equal opportunities law. © The Author 2015. Published by Oxford University Press on behalf of the Society of Occupational Medicine. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Attrition of fluid cracking catalyst in fluidized beds
DOE Office of Scientific and Technical Information (OSTI.GOV)
Boerefijn, R.; Ghadiri, M.
1996-12-31
Particle attrition in fluid catalytic cracking units causes loss of catalyst, which could amount to a few tonnes per day! The dependence of attrition on the process conditions and catalyst properties is therefore of great industrial interest, but it is however not well established at present. The process of attrition in the jetting area of fluidised beds is addressed and the attrition test method of Forsythe & Hertwig is analysed in this paper. This method is used commonly to assess the attrition propensity of FCC powder, whereby the attrition rate in a single jet at very high orifice velocity (300more » m s{sup -1}) is measured. There has been some concern on the relevance of this method to attrition in FCC units. Therefore, a previously-developed model of attrition in the jetting region is employed in an attempt to establish a solid basis of interpretation of the Forsythe & Hertwig test and its application as an industrial standard test. The model consists of two parts. The first part predicts the solids flow patterns in the jet region, simulating numerically the Forsythe & Hertwig test. The second part models the breakage of single particles upon impact. Combining these two models, thus linking single particle mechanical properties to macroscopic flow phenomena, results in the modelling of the attrition rate of particles entrained into a single high speed jet. High speed video recordings are made of a single jet in a two-dimensional fluidised bed, at up to 40500 frames per second, in order to quantify some of the model parameters. Digital analysis of the video images yields values for particle velocities and entrainment rates in the jet, which can be compared to model predictions. 15 refs., 8 figs.« less
Lysevych, M; Tan, H H; Karouta, F; Fu, L; Jagadish, C
2013-04-08
In this paper we report a method to overcome the limitations of gain-saturation and two-photon absorption faced by developers of high power single mode InP-based lasers and semiconductor optical amplifiers (SOA) including those based on wide-waveguide or slab-coupled optical waveguide laser (SCOWL) technology. The method is based on Y-coupling design of the laser cavity. The reduction in gain-saturation and two-photon absorption in the merged beam laser structures (MBL) are obtained by reducing the intensity of electromagnetic field in the laser cavity. Standard ridge-waveguide lasers and MBLs were fabricated, tested and compared. Despite a slightly higher threshold current, the reduced gain-saturation in MBLs results in higher output power. The MBLs also produced a single spatial mode, as well as a strongly dominating single spectral mode which is the inherent feature of MBL-type cavity.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-27
... Professionals: Standard Work Specifications for Single Family Energy Upgrades AGENCY: Office of Energy... Single Family Energy Upgrades (SWS). This content is a set of recommended work specifications applicable to energy efficiency retrofits of single family homes. These specifications are intended as a...
Detection of new HIV infections in a multicentre HIV antiretroviral pre-exposure prophylaxis trial.
Fransen, Katrien; de Baetselier, Irith; Rammutla, Elizabeth; Ahmed, Khatija; Owino, Frederick; Agingu, Walter; Venter, Gustav; Deese, Jen; Van Damme, Lut; Crucitti, Tania
2017-08-01
Monthly specimens collected from FEM-PrEP-a Phase III trial [1] were investigated for the detection of acute HIV (AHI) infection. To evaluate the efficiency of the study-specific HIV algorithm in detecting AHI, and the performance of each of the serological and molecular tests used in diagnosing new infections, and their contribution to narrowing the window period. A total of 83 pre-seroconversion specimens from 61 seroconverters from the FEM-PrEP trial were further analyzed in a sub-study. During the trial, HIV seroconversion was diagnosed on site using a testing algorithm with simple/rapid tests (SRTs) and confirmed with a gold standard testing algorithm (see short communication: Fig. 1). The infection date was determined more accurately by the use of standard ELISAs and Nucleic Acid Amplification Tests (NAAT) in a look-back procedure. For this sub-study, the international central laboratory repeated the study algorithm using SRTs. A total of 83 pre-seroconversions specimens from 61 seroconverters were analyzed in a look-back procedure. RNA was detected in 35/61 seroconverters at the visit before the seroconversion visit as determined at the study sites. Four seroconversion dates were inaccurate at one study site as the international central laboratory detected the HIV infection one visit earlier using the same test algorithm. Using the gold standard, an additional seroconversion was detected at an earlier visit. The combined antigen/antibody and the single antigen test had a higher sensitivity compared to the SRTs in detecting acute infections. In the FEM-PrEP trial, the international central laboratory detected a small number of seroconversions one month earlier than the study sites using the same study algorithm. Standard tests are still the most sensitive tests in detecting pre-seroconversion or acute HIV infection, but they are costly, time consuming and not recommended for use on-site in a clinical trial. Copyright © 2017 Elsevier B.V. All rights reserved.
Messerli, Michael; Ottilinger, Thorsten; Warschkow, René; Leschka, Sebastian; Alkadhi, Hatem; Wildermuth, Simon; Bauer, Ralf W
2017-06-01
To determine whether ultralow dose chest CT with tin filtration can be used for emphysema quantification and lung volumetry and to assess differences in emphysema measurements and lung volume between standard dose and ultralow dose CT scans using advanced modeled iterative reconstruction (ADMIRE). 84 consecutive patients from a prospective, IRB-approved single-center study were included and underwent clinically indicated standard dose chest CT (1.7±0.6mSv) and additional single-energy ultralow dose CT (0.14±0.01mSv) at 100kV and fixed tube current at 70mAs with tin filtration in the same session. Forty of the 84 patients (48%) had no emphysema, 44 (52%) had emphysema. One radiologist performed fully automated software-based pulmonary emphysema quantification and lung volumetry of standard and ultralow dose CT with different levels of ADMIRE. Friedman test and Wilcoxon rank sum test were used for multiple comparison of emphysema and lung volume. Lung volumes were compared using the concordance correlation coefficient. The median low-attenuation areas (LAA) using filtered back projection (FBP) in standard dose was 4.4% and decreased to 2.6%, 2.1% and 1.8% using ADMIRE 3, 4, and 5, respectively. The median values of LAA in ultralow dose CT were 5.7%, 4.1% and 2.4% for ADMIRE 3, 4, and 5, respectively. There was no statistically significant difference between LAA in standard dose CT using FBP and ultralow dose using ADMIRE 4 (p=0.358) as well as in standard dose CT using ADMIRE 3 and ultralow dose using ADMIRE 5 (p=0.966). In comparison with standard dose FBP the concordance correlation coefficients of lung volumetry were 1.000, 0.999, and 0.999 for ADMIRE 3, 4, and 5 in standard dose, and 0.972 for ADMIRE 3, 4 and 5 in ultralow dose CT. Ultralow dose CT at chest X-ray equivalent dose levels allows for lung volumetry as well as detection and quantification of emphysema. However, longitudinal emphysema analyses should be performed with the same scan protocol and reconstruction algorithms for reproducibility. Copyright © 2017 Elsevier B.V. All rights reserved.
Khanal, J; Poudyal, R R; Devkota, S; Thapa, S; Dhungana, R R
2015-01-01
Permanent pacemaker implantation is a minimally invasive surgical procedure in the management of patients with cardiac problems. However, complications during and after implantation are not uncommon. There is lack of evidences in rate of complications with the selection of pacemakers in Nepal. Therefore, this study was performed to compare the frequency of implantation and complication rate between single chamber and dual chamber pacemaker. The present study is based on all consecutive pacemaker implantations in a single centre between April 2014 and May 2015. A total of 116 patients were categorized into two cohorts according to the type of pacemaker implanted- single chamber or dual chamber. All patients had regular 2-weeks follow-up intervals with standardized documentation of all relevant patient data till 6-week after implantation. Data were presented as means ± standard deviation (SD) for continuous variables and as proportions for categorical variables. Comparison of continuous variables between the groups was made with independent Student's t-test. For discrete variables distribution between groups were compared with Chi-square test. The mean age (±SD) of total population at implant was 64.08 (± 15.09) years. Dual chamber units were implanted in 44 (37.93%) of patients, single chamber in 72 (62.06%). Only 14 women (31.81%) received dual chamber compared with 42 women (58.33%) who received single chamber (Chi-square=18, DF=1, P = 0.0084). Complete atrioventricular block was the commonest (56.03%) indication for permanent pacemaker insertion followed by sick sinus syndrome (33.62%), symptomatic high-grade AV block (11.20%). Hypertension (dual chamber 21.55%, single chamber 40.51%) was the most common comorbidity in both cohorts. Complications occurred in 11 (9.48%) patients. More proportion of complication occurred in single chamber group (9 patients, 12.50%) than in dual chamber (2 patients, 4.54%). Complications occurring in dual chamber group include pocket hematoma 1 patient (2.27%) and arrhythmia in 1 patient (2.27%). Similarly, complications occurring in single chamber include RV perforation in two patients (2.77%) and one each (1.38%) had pocket hematoma, pneumothorax, infection, swelling at pocket site, arrhythmia in the form of NSVT, leads displacement, DVT and mortality. Women were more likely to receive single chamber systems than men. More proportion of complication occurred in single chamber group than in dual chamber. Future prospective studies on larger number of patients are needed to confirm and support our findings.
Synthesis, characterization and biological studies of Schiff bases derived from heterocyclic moiety.
Shanty, Angamaly Antony; Philip, Jessica Elizabeth; Sneha, Eeettinilkunnathil Jose; Prathapachandra Kurup, Maliyeckal R; Balachandran, Sreedharannair; Mohanan, Puzhavoorparambil Velayudhan
2017-02-01
Some new Schiff bases (H 1 -H 7 ) have been synthesized by the condensation of 2-aminophenol, 2-amino-4-nitrophenol, 2-amino-4-methylphenol, 2-amino benzimidazole with thiophene-2-carboxaldehyde and pyrrole-2-carboxaldehyde. The structures of newly synthesized compounds were characterized by elemental analysis, FT-IR, 1 H NMR, UV-VIS, and single crystal X-ray crystallography. The in vitro antibacterial activity of the synthesized compounds has been tested against Salmonella typhi, Bacillus coagulans, Bacillus pumills, Escherichia coli, Bacillus circulans, Pseudomonas, Clostridium and Klebsilla pneumonia by disk diffusion method. The quantitative antimicrobial activity of the test compounds was evaluated using Resazurin based Microtiter Dilution Assay. Ampicillin was used as standard antibiotics. Schiff bases individually exhibited varying degrees of inhibitory effects on the growth of the tested bacterial species. The antioxidant activity of the synthesized compounds was determined by the 1,1-diphenyl-2-picrylhydrazyl(DPPH) method. IC 50 value of synthesized Schiff bases were calculated and compared with standard BHA. Copyright © 2016 Elsevier Inc. All rights reserved.
Novel microbial fuel cell design to operate with different wastewaters simultaneously.
Mathuriya, Abhilasha Singh
2016-04-01
A novel single cathode chamber and multiple anode chamber microbial fuel cell design (MAC-MFC) was developed by incorporating multiple anode chambers into a single unit and its performance was checked. During 60 days of operation, performance of MAC-MFC was assessed and compared with standard single anode/cathode chamber microbial fuel cell (SC-MFC). The tests showed that MAC-MFC generated stable and higher power outputs compared with SC-MFC and each anode chamber contributed efficiently. Further, MAC-MFCs were incorporated with different wastewaters in different anode chambers and their behavior in MFC performance was observed. MAC-MFC efficiently treated multiple wastewaters simultaneously at low cost and small space, which claims its candidature for future possible scale-up applications. Copyright © 2015. Published by Elsevier B.V.
Electromigration kinetics and critical current of Pb-free interconnects
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lu, Minhua; Rosenberg, Robert
2014-04-07
Electromigration kinetics of Pb-free solder bump interconnects have been studied using a single bump parameter sweep technique. By removing bump to bump variations in structure, texture, and composition, the single bump sweep technique has provided both activation energy and power exponents that reflect atomic migration and interface reactions with fewer samples, shorter stress time, and better statistics than standard failure testing procedures. Contact metallurgies based on Cu and Ni have been studied. Critical current, which corresponds to the Blech limit, was found to exist in the Ni metallurgy, but not in the Cu metallurgy. A temperature dependence of critical currentmore » was also observed.« less
Prüller, Florian; Wagner, Jasmin; Raggam, Reinhard B; Hoenigl, Martin; Kessler, Harald H; Truschnig-Wilders, Martie; Krause, Robert
2014-07-01
Testing for (1→3)-beta-D-glucan (BDG) is used for detection of invasive fungal infection. However, current assays lack automation and the ability to conduct rapid single-sample testing. The Fungitell assay was adopted for automation and evaluated using clinical samples from patients with culture-proven candidemia and from culture-negative controls in duplicate. A comparison with the standard assay protocol was made in order to establish analytical specifications. With the automated protocol, the analytical measuring range was 8-2500 pg/ml of BDG, and precision testing resulted in coefficients of variation that ranged from 3.0% to 5.5%. Samples from 15 patients with culture-proven candidemia and 94 culture-negative samples were evaluated. All culture-proven samples showed BDG values >80 pg/ml (mean 1247 pg/ml; range, 116-2990 pg/ml), which were considered positive. Of the 94 culture-negative samples, 92 had BDG values <60 pg/ml (mean, 28 pg/ml), which were considered to be negative, and 2 samples were false-positive (≥80 pg/ml; up to 124 pg/ml). Results could be obtained within 45 min and showed excellent agreement with results obtained with the standard assay protocol. The automated Fungitell assay proved to be reliable and rapid for diagnosis of candidemia. It was demonstrated to be feasible and cost efficient for both single-sample and large-scale testing of serum BDG. Its 1-h time-to-result will allow better support for clinicians in the management of antifungal therapy. © The Author 2014. Published by Oxford University Press on behalf of The International Society for Human and Animal Mycology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
A practical way to estimate retail tobacco sales violation rates more accurately.
Levinson, Arnold H; Patnaik, Jennifer L
2013-11-01
U.S. states annually estimate retailer propensity to sell adolescents cigarettes, which is a violation of law, by staging a single purchase attempt among a random sample of tobacco businesses. The accuracy of single-visit estimates is unknown. We examined this question using a novel test-retest protocol. Supervised minors attempted to purchase cigarettes at all retail tobacco businesses located in 3 Colorado counties. The attempts observed federal standards: Minors were aged 15-16 years, were nonsmokers, and were free of visible tattoos and piercings, and were allowed to enter stores alone or in pairs to purchase a small item while asking for cigarettes and to show or not show genuine identification (ID, e.g., driver's license). Unlike federal standards, stores received a second purchase attempt within a few days unless minors were firmly told not to return. Separate violation rates were calculated for first visits, second visits, and either visit. Eleven minors attempted to purchase cigarettes 1,079 times from 671 retail businesses. One sixth of first visits (16.8%) resulted in a violation; the rate was similar for second visits (15.7%). Considering either visit, 25.3% of businesses failed the test. Factors predictive of violation were whether clerks asked for ID, whether the clerks closely examined IDs, and whether minors included snacks or soft drinks in cigarette purchase attempts. A test-retest protocol for estimating underage cigarette sales detected half again as many businesses in violation as the federally approved one-test protocol. Federal policy makers should consider using the test-retest protocol to increase accuracy and awareness of widespread adolescent access to cigarettes through retail businesses.
NASA Astrophysics Data System (ADS)
Kasanzu, C.; Beucher, R.; Brown, R. W.; Persano, C.; Stuart, F.
2011-12-01
Apatite (U-Th)/he thermochronometry is one of the most widely used methods of quantifying thermal histories of rocks within the vicinity of the surface. Theoretical and practical development carried out during the last decade, among which was the release of affordable LASERs, have led to standard practice of analyzing single grain rather than multigrain aliquots. The standard theoretical basis for interpreting these ages assumes that the technique is used on full grains. However, the natural weak cleavage of apatite leads to fragmentation of these individual prismatic crystals during the rock crushing and mineral separation process. Apatites are most often broken along a weak cleavage perpendicular to the c-axis. It is therefore common practice to analyze fragments of whole grains, not complete crystals. It is also well known that dating often leads to single ages being more dispersed than expected whatever the efforts to avoid perturbations on the He system. Using a theoretical numerical model and considering both axial and radial diffusion, we demonstrate thata largepart (most?) of the dispersion is due to analyses of single apatite fragments. This effect is larger for older grains which have exprienced a slow cooling history and have well rounded diffusive profiles. Ages are a strongfunction of the fragment size (length specifically), we show that ages from apatite fragments with 1 prismatic termination (1T) can be used to retrieve the helium diffusion profile, provided a sufficient number of single fragment analyses are carried out. The shape of the helium diffusion profile provides a strong constraint on the style of the thermal history and so we propose to use single crystal fragment analyses to extract a mean diffusion profile, and deduce the thermal history of the sample. In order to test these ideas, we performed a set of experiments with natural samples and semi-synthetic grains of apatite. Synthetic grains are obtained by drilling cores of various length/width ratios within standard Durango crystals while natural grains are separated from a deep borehole in south-Africa (BK1) and from the Australian craton. Several experiences are presented: 1) (U-Th)/He dating of about 100 1T single-fragment aliquots of different shape ratio from the BK1 borehole; 2) (U-Th)/He dating of 20 2T single-fragment aliquot from an Australian sample previously dated following standard procedure. 3) (U-Th)/He dating of synthetic fragmentsfrom synthetic grains previously degassed by a known percentageusing a thermo-regulated furnace. The results of the experiments lead to important new insight into the natural dispersion of (U-Th)/He single-grain ages. They show that far from being problematic, highly dispersed data may indeed contain first-order information on the thermal history of rocks. We discuss all the details of the standard (U-Th)/He approach such as the effects of temporally variable diffusivity (e.g. radiation damage models), zonation of U and Th and arbitrary grain size variations.
Sudakov, S K; Nazarova, G A; Alekseeva, E V; Bashkatova, V G
2013-07-01
We compared individual anxiety assessed by three standard tests, open-field test, elevated plus-maze test, and Vogel conflict drinking test, in the same animals. No significant correlations between the main anxiety parameters were found in these three experimental models. Groups of animals with high and low anxiety rats were formed by a single parameter and subsequent selection of two extreme groups (10%). It was found that none of the tests could be used for reliable estimation of individual anxiety in rats. The individual anxiety level with high degree of confidence was determined in high-anxiety and low-anxiety rats demonstrating behavioral parameters above and below the mean values in all tests used. Therefore, several tests should be used for evaluation of the individual anxiety or sensitivity to emotional stress.
Koopmans, Bastijn; Smit, August B; Verhage, Matthijs; Loos, Maarten
2017-04-04
Systematic, standardized and in-depth phenotyping and data analyses of rodent behaviour empowers gene-function studies, drug testing and therapy design. However, no data repositories are currently available for standardized quality control, data analysis and mining at the resolution of individual mice. Here, we present AHCODA-DB, a public data repository with standardized quality control and exclusion criteria aimed to enhance robustness of data, enabled with web-based mining tools for the analysis of individually and group-wise collected mouse phenotypic data. AHCODA-DB allows monitoring in vivo effects of compounds collected from conventional behavioural tests and from automated home-cage experiments assessing spontaneous behaviour, anxiety and cognition without human interference. AHCODA-DB includes such data from mutant mice (transgenics, knock-out, knock-in), (recombinant) inbred strains, and compound effects in wildtype mice and disease models. AHCODA-DB provides real time statistical analyses with single mouse resolution and versatile suite of data presentation tools. On March 9th, 2017 AHCODA-DB contained 650 k data points on 2419 parameters from 1563 mice. AHCODA-DB provides users with tools to systematically explore mouse behavioural data, both with positive and negative outcome, published and unpublished, across time and experiments with single mouse resolution. The standardized (automated) experimental settings and the large current dataset (1563 mice) in AHCODA-DB provide a unique framework for the interpretation of behavioural data and drug effects. The use of common ontologies allows data export to other databases such as the Mouse Phenome Database. Unbiased presentation of positive and negative data obtained under the highly standardized screening conditions increase cost efficiency of publicly funded mouse screening projects and help to reach consensus conclusions on drug responses and mouse behavioural phenotypes. The website is publicly accessible through https://public.sylics.com and can be viewed in every recent version of all commonly used browsers.
Morrison, Sarah A; Forrest, Gail F; VanHiel, Leslie R; Davé, Michele; D'Urso, Denise
2012-09-01
To illustrate the continuity of care afforded by a standardized locomotor training program across a multisite network setting within the Christopher and Dana Reeve Foundation NeuroRecovery Network (NRN). Single patient case study. Two geographically different hospital-based outpatient facilities. This case highlights a 25-year-old man diagnosed with C4 motor incomplete spinal cord injury with American Spinal Injury Association Impairment Scale grade D. Standardized locomotor training program 5 sessions per week for 1.5 hours per session, for a total of 100 treatment sessions, with 40 sessions at 1 center and 60 at another. Ten-meter walk test and 6-minute walk test were assessed at admission and discharge across both facilities. For each of the 100 treatment sessions percent body weight support, average, and maximum treadmill speed were evaluated. Locomotor endurance, as measured by the 6-minute walk test, and overground gait speed showed consistent improvement from admission to discharge. Throughout training, the patient decreased the need for body weight support and was able to tolerate faster treadmill speeds. Data indicate that the patient continued to improve on both treatment parameters and walking function. Standardization across the NRN centers provided a mechanism for delivering consistent and reproducible locomotor training programs across 2 facilities without disrupting training or recovery progression. Copyright © 2012 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Visual field defects may not affect safe driving.
Dow, Jamie
2011-10-01
In Quebec a driver whose acquired visual field defect renders them ineligible for a driver's permit renewal may request an exemption from the visual field standard by demonstrating safe driving despite the defect. For safety reasons it was decided to attempt to identify predictors of failure on the road test in order to avoid placing driving evaluators in potentially dangerous situations when evaluating drivers with visual field defects. During a 4-month period in 2009 all requests for exemptions from the visual field standard were collected and analyzed. All available medical and visual field data were collated for 103 individuals, of whom 91 successfully completed the evaluation process and obtained a waiver. The collated data included age, sex, type of visual field defect, visual field characteristics, and concomitant medical problems. No single factor, or combination of factors, could predict failure of the road test. All 5 failures of the road test had cognitive problems but 6 of the successful drivers also had known cognitive problems. Thus, cognitive problems influence the risk of failure but do not predict certain failure. Most of the applicants for an exemption were able to complete the evaluation process successfully, thereby demonstrating safe driving despite their handicap. Consequently, jurisdictions that have visual field standards for their driving permit should implement procedures to evaluate drivers with visual field defects that render them unable to meet the standard but who wish to continue driving.
Hohnadel, Marisa; Maumy, Myriam; Chollet, Renaud
2018-01-01
For nearly a century, conventional microbiological methods have been standard practice for detecting and identifying pathogens in food. Nevertheless, the microbiological safety of food has improved and various rapid methods have been developed to overcome the limitations of conventional methods. Alternative methods are expected to detect low cell numbers, since the presence in food of even a single cell of a pathogenic organism may be infectious. With respect to low population levels, the performance of a detection method is assessed by producing serial dilutions of a pure bacterial suspension to inoculate representative food matrices with highly diluted bacterial cells (fewer than 10 CFU/ml). The accuracy of data obtained by multiple dilution techniques is not certain and does not exclude some colonies arising from clumps of cells. Micromanipulation techniques to capture and isolate single cells from environmental samples were introduced more than 40 years ago. The main limitation of the current micromanipulation technique is still the low recovery rate for the growth of a single cell in culture medium. In this study, we describe a new single cell isolation method and demonstrate that it can be used successfully to grow various types of microorganism from picked individual cells. Tests with Gram-positive and Gram-negative organisms, including cocci, rods, aerobes, anaerobes, yeasts and molds showed growth recovery rates from 60% to 100% after micromanipulation. We also highlight the use of our method to evaluate and challenge the detection limits of standard detection methods in food samples contaminated by a single cell of Salmonella enterica.
Design and fabrication of 55-gallon drum shuffler standards
DOE Office of Scientific and Technical Information (OSTI.GOV)
Long, S.M.; Hsue, F.; Hoth, C.
1994-08-01
To analyze waste with varying levels of nuclear material, suitable standards are needed to calibrate analytical instrumentation. At the Los Alamos Plutonium Facility, the authors have designed and fabricated a single drum standard for a passive-active neutron counter (shuffler). The standard is modified simply by adding or subtracting plutonium of uranium cylinders to adapt to a range of nuclear material. The plutonium or uranium oxide was placed into small cylindrical containers (1-in. diameter by 5-in. long) and diluted with diatomaceous earth. The cylinders were welded closed and removed from the glove box environment without any external contamination. The containers weremore » leak tested and then placed on a segmented gamma scanner to assure homogeneous distribution of the nuclear material. The cylinders are now placed into the drum to achieve the needed ranges for calibration of the instruments.« less
Reusable single-port access device shortens operative time and reduces operative costs.
Shussman, Noam; Kedar, Asaf; Elazary, Ram; Abu Gazala, Mahmoud; Rivkind, Avraham I; Mintz, Yoav
2014-06-01
In recent years, single-port laparoscopy (SPL) has become an attractive approach for performing surgical procedures. The pitfalls of this approach are technical and financial. Financial concerns are due to the increased cost of dedicated devices and prolonged operating room time. Our aim was to calculate the cost of SPL using a reusable port and instruments in order to evaluate the cost difference between this approach to SPL using the available disposable ports and standard laparoscopy. We performed 22 laparoscopic procedures via the SPL approach using a reusable single-port access system and reusable laparoscopic instruments. These included 17 cholecystectomies and five other procedures. Operative time, postoperative length of stay (LOS) and complications were prospectively recorded and were compared with similar data from our SPL database. Student's t test was used for statistical analysis. SPL was successfully performed in all cases. Mean operative time for cholecystectomy was 72 min (range 40-116). Postoperative LOS was not changed from our standard protocols and was 1.1 days for cholecystectomy. The postoperative course was within normal limits for all patients and perioperative morbidity was recorded. Both operative time and length of hospital stay were shorter for the 17 patients who underwent cholecystectomy using a reusable port than for the matched previous 17 SPL cholecystectomies we performed (p < 0.001). Prices of disposable SPL instruments and multiport access devices as well as extraction bags from different manufacturers were used to calculate the cost difference. Operating with a reusable port ended up with an average cost savings of US$388 compared with using disposable ports, and US$240 compared with standard laparoscopy. Single-port laparoscopic surgery is a technically challenging and expensive surgical approach. Financial concerns among others have been advocated against this approach; however, we demonstrate herein that using a reusable port and instruments reduces operative time and overall operative costs, even beyond the cost of standard laparoscopy.
Kretschmer, Alexander; Hüsch, Tanja; Thomsen, Frauke; Kronlachner, Dominik; Obaje, Alice; Anding, Ralf; Pottek, Tobias; Rose, Achim; Olianas, Roberto; Friedl, Alexander; Hübner, Wilhelm; Homberg, Roland; Pfitzenmaier, Jesco; Grein, Ulrich; Queissert, Fabian; Naumann, Carsten Maik; Schweiger, Josef; Wotzka, Carola; Nyarangi-Dix, Joanne N; Hofmann, Torben; Seiler, Roland; Haferkamp, Axel; Bauer, Ricarda M
2016-01-01
Background/Aims/Objectives: To analyze perioperative complication and short-term explantation rates after perineal or penoscrotal single-cuff and double-cuff artificial urinary sphincter (AUS) implantation in a large middle European multi-institutional patient cohort. 467 male patients with stress urinary incontinence underwent implantation of a perineal single-cuff (n = 152), penoscrotal single-cuff (n = 99), or perineal double-cuff (n = 216) AUS between 2010 and 2012. Postoperative complications and 6-month explantation rates were assessed. For statistical analysis, Fisher's exact test and Kruskal-Wallis rank sum test, and a multiple logistic regression model were used (p < 0.05). Compared to perineal single-cuff AUS, penoscrotal single-cuff implantation led to significantly increased short-term explantation rates (8.6% (perineal) vs. 19.2% (penoscrotal), p = 0.019). The postoperative infection rate was significantly higher after double-cuff compared to single-cuff implantation (6.0% (single-cuff) vs. 13.9% (double-cuff), p = 0.019). The short-term explantation rate after primary double-cuff placement was 6.5% (p = 0.543 vs. perineal single-cuff). In multivariate analysis, the penoscrotal approach (p = 0.004), intraoperative complications (p = 0.005), postoperative bleeding (p = 0.011), and perioperative infection (p < 0.001) were independent risk factors for short-term explantation. Providing data from a large contemporary multi-institutional patient cohort from high-volume and low-volume institutions, our results reflect the current standard of care in middle Europe. We indicate that the penoscrotal approach is an independent risk factor for increased short-term explantation rates. © 2016 S. Karger AG, Basel.
Vallila-Rohter, Sofia; Kiran, Swathi
2015-08-01
Our purpose was to study strategy use during nonlinguistic category learning in aphasia. Twelve control participants without aphasia and 53 participants with aphasia (PWA) completed a computerized feedback-based category learning task consisting of training and testing phases. Accuracy rates of categorization in testing phases were calculated. To evaluate strategy use, strategy analyses were conducted over training and testing phases. Participant data were compared with model data that simulated complex multi-cue, single feature, and random pattern strategies. Learning success and strategy use were evaluated within the context of standardized cognitive-linguistic assessments. Categorization accuracy was higher among control participants than among PWA. The majority of control participants implemented suboptimal or optimal multi-cue and single-feature strategies by testing phases of the experiment. In contrast, a large subgroup of PWA implemented random patterns, or no strategy, during both training and testing phases of the experiment. Person-to-person variability arises not only in category learning ability but also in the strategies implemented to complete category learning tasks. PWA less frequently developed effective strategies during category learning tasks than control participants. Certain PWA may have impairments of strategy development or feedback processing not captured by language and currently probed cognitive abilities.
Mockett, Robin J; Nobles, Amber C
2013-10-01
The hypothesis tested in this study was that single-gene mutations found previously to extend the life span of Drosophila melanogaster could do so consistently in both long-lived y w and standard w (1118) genetic backgrounds. GAL4 drivers were used to express upstream activation sequence (UAS)-responder transgenes globally or in the nervous system. Transgenes associated with oxidative damage prevention (UAS-hSOD1 and UAS-GCLc) or removal (EP-UAS-Atg8a and UAS-dTOR (FRB) ) failed to increase mean life spans in any expression pattern in either genetic background. Flies containing a UAS-EGFP-bMSRA (C) transgene associated with protein repair were found not to exhibit life extension or detectable enhanced green fluorescent protein (EGFP) activity. The presence of UAS-responder transgenes was confirmed by PCR amplification and sequencing at the 5' and 3' end of each insertion. These results cast doubt on the robustness of life extension in flies carrying single-gene mutations and suggest that the effects of all such mutations should be tested independently in multiple genetic backgrounds and laboratory environments.
Kalim, Shahid; Nazir, Shaista; Khan, Zia Ullah
2013-01-01
Protocols based on newer high sensitivity Troponin T (hsTropT) assays can rule in a suspected Acute Myocardial Infarction (AMI) as early as 3 hours. We conducted this study to audit adherence to our Trust's newly introduced AMI diagnostic protocol based on paired hsTropT testing at 0 and 3 hours. We retrospectively reviewed data of all patients who had hsTropT test done between 1st and 7th May 2012. Patient's demographics, utility of single or paired samples, time interval between paired samples, patient's presenting symptoms and ECG findings were noted and their means, medians, Standard deviations and proportions were calculated. A total of 66 patients had hsTropT test done during this period. Mean age was 63.30 +/- 17.46 years and 38 (57.57%) were males. Twenty-four (36.36%) patients had only single, rather than protocol recommended paired hsTropT samples, taken. Among the 42 (63.63%) patients with paired samples, the mean time interval was found to be 4.41 +/- 5.7 hours. Contrary to the recommendations, 15 (22.73%) had a very long whereas 2 (3.03%) had a very short time interval between two samples. A subgroup analysis of patients with single samples, found only 2 (3.03%) patient with ST-segment elevation, appropriate for single testing. Our study confirmed that in a large number of patients the protocol for paired sampling or a recommended time interval of 3 hours between 2 samples was not being followed.
Leshem, Eran; Suleiman, Mahmoud; Laish-Farkash, Avishag; Konstantino, Yuval; Glikson, Michael; Barsheshet, Alon; Goldenberg, Ilan; Michowitz, Yoav
2017-09-01
Dual-coil leads were traditionally considered standard of care due to lower defibrillation thresholds (DFT). Higher complication rates during extraction with parallel progression in implantable cardioverter defibrillator (ICD) technology raised questions on dual coil necessity. Prior substudies found no significant outcome difference between dual and single coils, although using higher rates of DFT testing then currently practiced. We evaluated the temporal trends in implantation rates of single- vs. dual-coil leads and determined the associated adverse clinical outcomes, using a contemporary nation-wide ICD registry. Between July 2010 and March 2015, 6343 consecutive ICD (n = 3998) or CRT-D (n = 2345) implantation patients were prospectively enrolled in the Israeli ICD Registry. A follow-up of at least 1 year of 2285 patients was available for outcome analysis. The primary endpoint was all-cause mortality. Single-coil leads were implanted in 32% of our cohort, 36% among ICD recipients, and 26% among CRT-D recipients. Secondary prevention indication was associated with an increased rate of dual-coil implantation. A significant decline in dual-coil leads with reciprocal incline of single coils was observed, despite low rates of DFT testing (11.6%) during implantation, which also declined from 31 to 2%. In the multivariate Cox model analysis, dual- vs. single-coil lead implantation was not associated with an increased risk of mortality [hazard ratio (HR) = 1.23; P= 0.33], heart failure hospitalization (HR = 1.34; P=0.13), appropriate (HR = 1.25; P= 0.33), or inappropriate ICD therapy (HR = 2.07; P= 0.12). Real-life rates of single-coil lead implantation are rising while adding no additional risk. These results of single-coil safety are reassuring and obtained, despite low and contemporary rates of DFT testing. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.
Interchangeability of gas detection tubes and hand pumps.
Haag, W R
2001-01-01
Users of gas detection tubes occasionally seek the convenience of using a single hand pump with different brands of tubes, to avoid the need to carry more than one pump. Several professional organizations recommend against such interchange. However, these recommendations appear to be based on a single study of pump designs that mostly are no longer in use. The present study was undertaken to determine if current hand pumps are interchangeable. Both piston-type and bellows-type hand pumps were evaluated by comparing pump flow profiles and test gas measurements with a variety of tubes. The results demonstrate that three piston hand pumps in common use (Sensidyne/Gastec GV/100, RAE Systems LP-1200, and Matheson-Kitagawa 8104-400A) are fully interchangeable. Two bellows pumps (Draeger Accuro and MSA Kwik-Draw) also are interchangeable with each other. Mixing of bellows and piston systems is often possible, but there are enough exceptions to conclude that such practice should be discouraged because it can give inaccurate readings. It is recommended that technical standards be adopted, such as total volume and an initial pump vacuum or a pump flow curve, to assess hand pump interchangeability. When two manufacturers' pumps meet the same standard and routine leak tests are conducted, interchangeability is scientifically valid and poses no risk to the end user while offering greater convenience.
Testing single point incremental forming moulds for rotomoulding operations
NASA Astrophysics Data System (ADS)
Afonso, Daniel; de Sousa, Ricardo Alves; Torcato, Ricardo
2017-10-01
Low pressure polymer processes as thermoforming or rotational moulding use much simpler moulds than high pressure processes like injection. However, despite the low forces involved in the process, moulds manufacturing for these applications is still a very material, energy and time consuming operation. Particularly in rotational moulding there is no standard for the mould manufacture and very different techniques are applicable. The goal of this research is to develop and validate a method for manufacturing plastically formed sheet metal moulds by single point incremental forming (SPIF) for rotomoulding and rotocasting operations. A Stewart platform based SPIF machine allow the forming of thick metal sheets, granting the required structural stiffness for the mould surface, and keeping a short manufacture lead time and low thermal inertia. The experimental work involves the proposal of a hollow part, design and fabrication of a sheet metal mould using dieless incremental forming techniques and testing its operation in the production of prototype parts.
Coil geometry effects on scanning single-coil magnetic induction tomography
NASA Astrophysics Data System (ADS)
Feldkamp, Joe R.; Quirk, Stephen
2017-09-01
Alternative coil designs for single coil magnetic induction tomography are considered in this work, with the intention of improving upon the standard design used previously. In particular, we note that the blind spot associated with this coil type, a portion of space along its axis where eddy current generation can be very weak, has an important effect on performance. The seven designs tested here vary considerably in the size of their blind spot. To provide the most discerning test possible, we use laboratory phantoms containing feature dimensions similar to blind spot size. Furthermore, conductivity contrasts are set higher than what would occur naturally in biological systems, which has the effect of weakening eddy current generation at coil locations that straddle the border between high and low conductivity features. Image reconstruction results for the various coils show that coils with smaller blind spots give markedly better performance, though improvements in signal-to-noise ratio could alter that conclusion.
A study of interior noise levels, noise sources and transmission paths in light aircraft
NASA Technical Reports Server (NTRS)
Hayden, R. E.; Murray, B. S.; Theobald, M. A.
1983-01-01
The interior noise levels and spectral characteristics of 18 single-and twin-engine propeller-driven light aircraft, and source-path diagnosis of a single-engine aircraft which was considered representative of a large part of the fleet were studied. The purpose of the flight surveys was to measure internal noise levels and identify principal noise sources and paths under a carefully controlled and standardized set of flight procedures. The diagnostic tests consisted of flights and ground tests in which various parts of the aircraft, such as engine mounts, the engine compartment, exhaust pipe, individual panels, and the wing strut were instrumented to determine source levels and transmission path strengths using the transfer function technique. Predominant source and path combinations are identified. Experimental techniques are described. Data, transfer function calculations to derive source-path contributions to the cabin acoustic environment, and implications of the findings for noise control design are analyzed.
Apicella, Coren L.; Cesarini, David; Johannesson, Magnus; Dawes, Christopher T.; Lichtenstein, Paul; Wallace, Björn; Beauchamp, Jonathan; Westberg, Lars
2010-01-01
Background Oxytocin (OXT) has been implicated in a suite of complex social behaviors including observed choices in economic laboratory experiments. However, actual studies of associations between oxytocin receptor (OXTR) gene variants and experimentally elicited social preferences are rare. Methodology/Principal Findings We test hypotheses of associations between social preferences, as measured by behavior in two economic games, and 9 single nucleotide polymorphisms (SNPs) of the OXTR gene in a sample of Swedish twins (n = 684). Two standard economic games, the dictator game and the trust game, both involving real monetary consequences, were used to elicit such preferences. After correction for multiple hypothesis testing, we found no significant associations between any of the 9 single nucleotide polymorphisms (SNPs) and behavior in either of the games. Conclusion We were unable to replicate the most significant association reported in previous research between the amount donated in a dictator game and an OXTR genetic variant. PMID:20585395
Syal, Karan; Shen, Simon; Yang, Yunze; Wang, Shaopeng; Haydel, Shelley E; Tao, Nongjian
2017-08-25
To combat antibiotic resistance, a rapid antibiotic susceptibility testing (AST) technology that can identify resistant infections at disease onset is required. Current clinical AST technologies take 1-3 days, which is often too slow for accurate treatment. Here we demonstrate a rapid AST method by tracking sub-μm scale bacterial motion with an optical imaging and tracking technique. We apply the method to clinically relevant bacterial pathogens, Escherichia coli O157: H7 and uropathogenic E. coli (UPEC) loosely tethered to a glass surface. By analyzing dose-dependent sub-μm motion changes in a population of bacterial cells, we obtain the minimum bactericidal concentration within 2 h using human urine samples spiked with UPEC. We validate the AST method using the standard culture-based AST methods. In addition to population studies, the method allows single cell analysis, which can identify subpopulations of resistance strains within a sample.
Apicella, Coren L; Cesarini, David; Johannesson, Magnus; Dawes, Christopher T; Lichtenstein, Paul; Wallace, Björn; Beauchamp, Jonathan; Westberg, Lars
2010-06-16
Oxytocin (OXT) has been implicated in a suite of complex social behaviors including observed choices in economic laboratory experiments. However, actual studies of associations between oxytocin receptor (OXTR) gene variants and experimentally elicited social preferences are rare. We test hypotheses of associations between social preferences, as measured by behavior in two economic games, and 9 single nucleotide polymorphisms (SNPs) of the OXTR gene in a sample of Swedish twins (n = 684). Two standard economic games, the dictator game and the trust game, both involving real monetary consequences, were used to elicit such preferences. After correction for multiple hypothesis testing, we found no significant associations between any of the 9 single nucleotide polymorphisms (SNPs) and behavior in either of the games. We were unable to replicate the most significant association reported in previous research between the amount donated in a dictator game and an OXTR genetic variant.
Primary care validation of a single-question alcohol screening test.
Smith, Peter C; Schmidt, Susan M; Allensworth-Davies, Donald; Saitz, Richard
2009-07-01
Unhealthy alcohol use is prevalent but under-diagnosed in primary care settings. To validate, in primary care, a single-item screening test for unhealthy alcohol use recommended by the National Institute on Alcohol Abuse and Alcoholism (NIAAA). Cross-sectional study. Adult English-speaking patients recruited from primary care waiting rooms. Participants were asked the single screening question, “How many times in the past year have you had X or more drinks in a day?”, where X is 5 for men and 4 for women, and a response of 1 or greater [corrected] is considered positive. Unhealthy alcohol use was defined as the presence of an alcohol use disorder, as determined by a standardized diagnostic interview, or risky consumption, as determined using a validated 30-day calendar method. Of 394 eligible primary care patients, 286 (73%) completed the interview. The single-question screen was 81.8% sensitive (95% confidence interval (CI) 72.5% to 88.5%) and 79.3% specific (95% CI 73.1% to 84.4%) for the detection of unhealthy alcohol use. It was slightly more sensitive (87.9%, 95% CI 72.7% to 95.2%) but was less specific (66.8%, 95% CI 60.8% to 72.3%) for the detection of a current alcohol use disorder. Test characteristics were similar to that of a commonly used three-item screen, and were affected very little by subject demographic characteristics. The single screening question recommended by the NIAAA accurately identified unhealthy alcohol use in this sample of primary care patients. These findings support the use of this brief screen in primary care.
Test for Non-Synergistic Interactions in Phytomedicine, Just as You Do for Isolated Compounds
Patel, Areeba; Mondal, Amit
2018-01-01
Phytomedicine has often been used as “alternative therapy,” which in our opinion is unfortunate as it prevents its main actions being systematically studied, side effects explored, and toxicity tested, like all single-compound-based medicine. Our group is interested in finding which traditional or modern phytomedicines actually work and which are simply “working” through placebo, standardizing phytomedicine preparations, studying their toxicity, and finding active molecules in plants for modification and chemical synthesis as single compounds. Although fluctuation in efficacy due to seasonal and geographical variations in phytomedicine remains a concern, if well regulated, even plant extracts without isolated compounds can serve medicinal needs where single-compound options are currently not great. A potential concern with such phytomedicine is frequent mixing of ingredients in commercial formulations without test of synergism. Our study on the use of 2 traditional plants for Parkinson disease shows a clear lack of synergism, and to study nonsynergism better, we developed a new visualization approach. In this commentary, using our study on Parkinson disease as an example, we make a case for better evaluation of phytomedicines, especially testing for synergistic interactions. We also critique our own exploration of oxidative stress and few behavioral parameters alone to lay grounds for what we and hopefully others can do in future to extract more information from their phytomedicine studies. We hope this commentary acts as a good warning for anyone mixing 2 phytomedicines without testing. PMID:29706766
Test for Non-Synergistic Interactions in Phytomedicine, Just as You Do for Isolated Compounds.
Patel, Areeba; Khan, Farooq Ali; Sikdar, Arindam; Mondal, Amit; Shukla, Sunil Dutt; Khurana, Sukant
2018-01-01
Phytomedicine has often been used as "alternative therapy," which in our opinion is unfortunate as it prevents its main actions being systematically studied, side effects explored, and toxicity tested, like all single-compound-based medicine. Our group is interested in finding which traditional or modern phytomedicines actually work and which are simply "working" through placebo, standardizing phytomedicine preparations, studying their toxicity, and finding active molecules in plants for modification and chemical synthesis as single compounds. Although fluctuation in efficacy due to seasonal and geographical variations in phytomedicine remains a concern, if well regulated, even plant extracts without isolated compounds can serve medicinal needs where single-compound options are currently not great. A potential concern with such phytomedicine is frequent mixing of ingredients in commercial formulations without test of synergism. Our study on the use of 2 traditional plants for Parkinson disease shows a clear lack of synergism, and to study nonsynergism better, we developed a new visualization approach. In this commentary, using our study on Parkinson disease as an example, we make a case for better evaluation of phytomedicines, especially testing for synergistic interactions. We also critique our own exploration of oxidative stress and few behavioral parameters alone to lay grounds for what we and hopefully others can do in future to extract more information from their phytomedicine studies. We hope this commentary acts as a good warning for anyone mixing 2 phytomedicines without testing.
Migo, Ellen M; Quamme, Joel R; Holmes, Selina; Bendell, Andrew; Norman, Kenneth A; Mayes, Andrew R; Montaldi, Daniela
2014-01-01
In forced-choice recognition memory, two different testing formats are possible under conditions of high target-foil similarity: Each target can be presented alongside foils similar to itself (forced-choice corresponding; FCC), or alongside foils similar to other targets (forced-choice noncorresponding; FCNC). Recent behavioural and neuropsychological studies suggest that FCC performance can be supported by familiarity whereas FCNC performance is supported primarily by recollection. In this paper, we corroborate this finding from an individual differences perspective. A group of older adults were given a test of FCC and FCNC recognition for object pictures, as well as standardized tests of recall, recognition, and IQ. Recall measures were found to predict FCNC, but not FCC performance, consistent with a critical role for recollection in FCNC only. After the common influence of recall was removed, standardized tests of recognition predicted FCC, but not FCNC performance. This is consistent with a contribution of only familiarity in FCC. Simulations show that a two-process model, where familiarity and recollection make separate contributions to recognition, is 10 times more likely to give these results than a single-process model. This evidence highlights the importance of recognition memory test design when examining the involvement of recollection and familiarity.
NASA Astrophysics Data System (ADS)
Wang, Jing; Tronville, Paolo
2014-06-01
The filtration of airborne nanoparticles is an important control technique as the environmental, health, and safety impacts of nanomaterials grow. A review of the literature shows that significant progress has been made on airborne nanoparticle filtration in the academic field in the recent years. We summarize the filtration mechanisms of fibrous and membrane filters; the air flow resistance and filter media figure of merit are discussed. Our review focuses on the air filtration test methods and instrumentation necessary to implement them; recent experimental studies are summarized accordingly. Two methods using monodisperse and polydisperse challenging aerosols, respectively, are discussed in detail. Our survey shows that the commercial instruments are already available for generating a large amount of nanoparticles, sizing, and quantifying them accurately. The commercial self-contained filter test systems provide the possibility of measurement for particles down to 15 nm. Current international standards dealing with efficiency test for filters and filter media focus on measurement of the minimum efficiency at the most penetrating particle size. The available knowledge and instruments provide a solid base for development of test methods to determine the effectiveness of filtration media against airborne nanoparticles down to single-digit nanometer range.
Graphical method for comparative statistical study of vaccine potency tests.
Pay, T W; Hingley, P J
1984-03-01
Producers and consumers are interested in some of the intrinsic characteristics of vaccine potency assays for the comparative evaluation of suitable experimental design. A graphical method is developed which represents the precision of test results, the sensitivity of such results to changes in dosage, and the relevance of the results in the way they reflect the protection afforded in the host species. The graphs can be constructed from Producer's scores and Consumer's scores on each of the scales of test score, antigen dose and probability of protection against disease. A method for calculating these scores is suggested and illustrated for single and multiple component vaccines, for tests which do or do not employ a standard reference preparation, and for tests which employ quantitative or quantal systems of scoring.
CPM Test-Retest Reliability: "Standard" vs "Single Test-Stimulus" Protocols.
Granovsky, Yelena; Miller-Barmak, Adi; Goldstein, Oren; Sprecher, Elliot; Yarnitsky, David
2016-03-01
Assessment of pain inhibitory mechanisms using conditioned pain modulation (CPM) is relevant clinically in prediction of pain and analgesic efficacy. Our objective is to provide necessary estimates of intersession CPM reliability, to enable transformation of the CPM paradigm into a clinical tool. Two cohorts of young healthy subjects (N = 65) participated in two dual-session studies. In Study I, a Bath-Thermode CPM protocol was used, with hot water immersion and contact heat as conditioning- and test-stimuli, respectively, in a classical parallel CPM design introducing test-stimulus first, and then the conditioning- and repeated test-stimuli in parallel. Study II consisted of two CPM protocols: 1) Two-Thermodes, one for each of the stimuli, in the same parallel design as above, and 2) single test-stimulus (STS) protocol with a single administration of a contact heat test-stimulus, partially overlapped in time by a remote shorter contact heat as conditioning stimulus. Test-retest reliability was assessed within 3-7 days. The STS-CPM had superior reliability intraclass correlation (ICC 2 ,: 1 = 0.59) over Bath-Thermode (ICC 2 ,: 1 = 0.34) or Two-Thermodes (ICC 2 ,: 1 = 0.21) protocols. The hand immersion conditioning pain had higher reliability than thermode pain (ICC 2 ,: 1 = 0.76 vs ICC 2 ,: 1 = 0.16). Conditioned test-stimulus pain scores were of good (ICC 2 ,: 1 = 0.62) or fair (ICC 2 ,: 1 = 0.43) reliability for the Bath-Thermode and the STS, respectively, but not for the Two-Thermodes protocol (ICC 2 ,: 1 = 0.20). The newly developed STS-CPM paradigm was more reliable than other CPM protocols tested here, and should be further investigated for its clinical relevance. It appears that large contact size of the conditioning-stimulus and use of single rather than dual test-stimulus pain contribute to augmentation of CPM reliability. © 2015 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Transformational Play as a Curricular Scaffold: Using Videogames to Support Science Education
NASA Astrophysics Data System (ADS)
Barab, Sasha A.; Scott, Brianna; Siyahhan, Sinem; Goldstone, Robert; Ingram-Goble, Adam; Zuiker, Steven J.; Warren, Scott
2009-08-01
Drawing on game-design principles and an underlying situated theoretical perspective, we developed and researched a 3D game-based curriculum designed to teach water quality concepts. We compared undergraduate student dyads assigned randomly to four different instructional design conditions where the content had increasingly level of contextualization: (a) expository textbook condition, (b) simplistic framing condition, (c) immersive world condition, and (d) a single-user immersive world condition. Results indicated that the immersive-world dyad and immersive-world single user conditions performed significantly better than the electronic textbook group on standardized items. The immersive-world dyad condition also performed significantly better than either the expository textbook or the descriptive framing condition on a performance-based transfer task, and performed significantly better than the expository textbook condition on standardized test items. Implications for science education, and consistent with the goals of this special issue, are that immersive game-based learning environments provide a powerful new form of curriculum for teaching and learning science.
Drawbar Pull (DP) Procedures for Off-Road Vehicle Testing
NASA Technical Reports Server (NTRS)
Creager, Colin; Asnani, Vivake; Oravec, Heather; Woodward, Adam
2017-01-01
As NASA strives to explore the surface of the Moon and Mars, there is a continued need for improved tire and vehicle development. When tires or vehicles are being designed for off-road conditions where significant thrust generation is required, such as climbing out of craters on the Moon, it is important to use a standard test method for evaluating their tractive performance. The drawbar pull (DP) test is a way of measuring the net thrust generated by tires or a vehicle with respect to performance metrics such as travel reduction, sinkage, or power efficiency. DP testing may be done using a single tire on a traction rig, or with a set of tires on a vehicle; this report focuses on vehicle DP tests. Though vehicle DP tests have been used for decades, there are no standard procedures that apply to exploration vehicles. This report summarizes previous methods employed, shows the sensitivity of certain test parameters, and provides a body of knowledge for developing standard testing procedures. The focus of this work is on lunar applications, but these test methods can be applied to terrestrial and planetary conditions as well. Section 1.0 of this report discusses the utility of DP testing for off-road vehicle evaluation and the metrics used. Section 2.0 focuses on test-terrain preparation, using the example case of lunar terrain. There is a review of lunar terrain analogs implemented in the past and a discussion on the lunar terrain conditions created at the NASA Glenn Research Center, including methods of evaluating the terrain strength variation and consistency from test to test. Section 3.0 provides details of the vehicle test procedures. These consist of a review of past methods, a comprehensive study on the sensitivity of test parameters, and a summary of the procedures used for DP testing at Glenn.
Two-locus diseas models with two marker loci: The power of affected-sib-pair tests
DOE Office of Scientific and Technical Information (OSTI.GOV)
Knapp, M.; Seuchter, S.A.; Bauer, M.P.
1994-11-01
Recently, Schork et al. found that two-trait-locus, two-marker-locus (parametric) linkage analysis can provide substantially more linkage information than can standard one-trait-locus, one-marker-locus methods. However, because of the increased burden of computation, Schork et al. do not expect that their approach will be applied in an initial genome scan. Further, the specification of a suitable two-locus segregation model can be crucial. Affected-sib-pair tests are computationally simple and do not require an explicit specification of the disease model. In the past, however, these tests mainly have been applied to data with a single marker locus. Here, we consider sib-pair tests that makemore » it possible to analyze simultaneously two marker loci. The power of these tests is investigated for different (epistatic and heterogeneous) two-trait-locus models, each trait locus being linked to one of the marker loci. We compare these tests both with the test that is optimal for a certain model and with the strategy that analyzes each marker locus separately. The results indicate that a straightforward extension of the well-known mean test for two marker loci can be much more powerful than single-marker-locus analysis and that its power is only slightly inferior to the power of the optimal test. 21 refs., 5 figs., 2 tabs.« less
Zietek, P; Zietek, J; Szczypior, K; Safranow, K
2015-06-01
Earlier and more intensive physiotherapy exercise after total knee arthroplasty (TKA) enhance recovery, but the best combination of intensity and duration has not been determined. To determine whether adding a single, 15-minute walk on the day of surgery to a fast-track rehabilitation protocol would reduce knee pain and improve knee function after TKA. A randomized single-blind study. Inpatient. Patients with primary osteoarthrosis after TKA. Patients undergoing TKA were randomly assigned to a standard, fast-track rehabilitation protocol consisting of a single, 15-minute walk with a high-rolling walker 4 to 6 hours after recovery from spinal anesthesia or to an intensive protocol, in which patients took a second 15-minute walk at least 3 hours after the first, only on the day of surgery. Outcomes were pain measured on a visual analog scale, Knee Society's (KSS) clinical and functional scores, Oxford knee scores, and Spielberger State-Trait Anxiety Inventory scores. Patients were blinded to group assignment. Since most data were non-normally distributed non-parametric tests were used. Groups were compared with Mann-Whitney U test (for continuous variables). Association between continuous variables was evaluated with Spearman`s rank correlation coefficient. Chi-square or Fisher's exact test was used to assess differences in categorical variables. Of 86 patients assessed for eligibility, 66 were randomly assigned. The 31 evaluable patients on the intensive protocol (mean age, 68 years; 18 women) did not differ significantly from the 31 (mean age, 70 years; 20 women) on the standard protocol on any baseline characteristic or on any outcome measure on any day. On the second postoperative day, pain while walking dropped from a mean of 6.1 to a mean of 4.9 in the intensive group and from 6.4 to 5.4 in the standard group. Results for pain at rest were 3.3 to 2.2, respectively, for the intensive group and 4.0 to 3.0 for the standard group. At 2 weeks, pain at rest was 2.8 in both groups, and pain while walking was 3.0, respectively, for the intensive group and 3.4 for the standard group. At 2 weeks, mean (SD) KSS clinical and KSS function scores were, respectively, 74.9 (12.5) and 51.6 (16.2) in the intensive group and 71.2 (14.3) and 46.3 (16.1) in the standard group. Older age correlated with decreasing knee function (rS=-0.43, P<0.001), and less knee flexion correlated with preoperatively higher state anxiety (rS=-0.37, P=0.005) and trait anxiety (rS=-0.29, P=0.027). The study is limited by its small sample. The fast-track program was not in line with the best available evidence following knee arthroplasty, because patients did not undergo such treatment as NMES. Finally, the intervention itself was modest. Adding an additional 15-minute walk to a fast-track rehabilitation protocol did not increase pain, but neither did it improve functional recovery. A 15-minute walk immediately after recovery from spinal anesthesia did not increase pain in patients with TKA. More intense exercise during this period might improve functional recovery without increasing pain.
Traceable calibration of ultraviolet meters used with broadband, extended sources.
Coleman, A J; Collins, M; Saunders, J E
2000-01-01
A calibration system has been developed to provide increased accuracy in the measurement of the irradiance responsivity appropriate for UV meters used with broadband, extended sources of the type employed in phototherapy. The single wavelength responsivity of the test meter is obtained in the wavelength range 250-400 nm by intercomparison with a transfer standard meter in a narrow, monochromatic beam. Traceability to primary standard irradiance scales is provided via the National Measurement System with a best uncertainty of 7% (at 95% confidence). The effective responsivity of the test meter, when used with broadband extended sources, is calculated using the measured spectral and angular response of the meter and tabulated data on the spectral and spatial characteristics of the source radiance. The uncertainty in the effective responsivity, independent of the source variability, is estimated to be 10% (at 95% confidence). The advantages of this calibration system over existing approaches are discussed.
Performance characterization of structured light-based fingerprint scanner
NASA Astrophysics Data System (ADS)
Hassebrook, Laurence G.; Wang, Minghao; Daley, Raymond C.
2013-05-01
Our group believes that the evolution of fingerprint capture technology is in transition to include 3-D non-contact fingerprint capture. More specifically we believe that systems based on structured light illumination provide the highest level of depth measurement accuracy. However, for these new technologies to be fully accepted by the biometric community, they must be compliant with federal standards of performance. At present these standards do not exist for this new biometric technology. We propose and define a set of test procedures to be used to verify compliance with the Federal Bureau of Investigation's image quality specification for Personal Identity Verification single fingerprint capture devices. The proposed test procedures include: geometric accuracy, lateral resolution based on intensity or depth, gray level uniformity and flattened fingerprint image quality. Several 2-D contact analogies, performance tradeoffs and optimization dilemmas are evaluated and proposed solutions are presented.
Cost-effectiveness of nivolumab for recurrent or metastatic head and neck cancer☆.
Ward, Matthew C; Shah, Chirag; Adelstein, David J; Geiger, Jessica L; Miller, Jacob A; Koyfman, Shlomo A; Singer, Mendel E
2017-11-01
Nivolumab is the first drug to demonstrate a survival benefit for platinum-refractory recurrent or metastatic head and neck cancer. We performed a cost-utility analysis to assess the economic value of nivolumab as compared to alternative standard agents in this context. Using data from the CheckMate 141 trial, we constructed a Markov simulation model from the US payer's perspective to evaluate the cost-effectiveness of nivolumab compared to physician choice of either cetuximab, methotrexate or docetaxel. Alternative strategies considered included: single-agent cetuximab, methotrexate or docetaxel, or first testing for PD-L1 to select for nivolumab. Costs were extracted from Medicare and utilities from the literature and CheckMate. Probabilistic sensitivity analysis (PSA) was used to evaluate parameter uncertainty. $100,000/QALY was the primary threshold for cost-effectiveness. When comparing nivolumab to the standard arm of CheckMate, nivolumab demonstrated an incremental cost-effectiveness ratio (ICER) of $140,672/QALY. When comparing standard therapies, methotrexate was the most cost-effective with similar results for docetaxel. Nivolumab was cost-effective compared to single-agent cetuximab (ICER $89,786/QALY). Treatment selection by PD-L1 immunohistochemistry did not markedly improve the cost-effectiveness of nivolumab. Factors likely to positively impact the cost-effectiveness of nivolumab include better baseline quality-of-life, poor tolerability of standard treatments and/or a lower cost of nivolumab. Nivolumab is preferred to single-agent cetuximab but requires a willingness-to-pay of at least $150,000/QALY to be considered cost-effective when compared to docetaxel or methotrexate. Selection by PD-L1 does not markedly improve the cost-effectiveness of nivolumab. This informs patient selection and clinical care-path development. Copyright © 2017 Elsevier Ltd. All rights reserved.
Mason, H J; Poole, K; Saxton, J
2003-08-01
Accurate diagnosis and staging of hand-arm vibration syndrome (HAVS) is important in health surveillance of vibration-exposed workers and the substantial number of related medico-legal cases. The measurement of the rewarming rate of fingers after cold provocation to the hands (CPT) has been suggested as a useful test in diagnosing HAVS. To investigate the diagnostic value of a standardized version of the CPT test using a 15 degrees C cold challenge for 5 min applied in the recent compensation assessment of UK miners. Analysis of a subset of UK miners assessed at our unit, together with data from a small repeatability study of the standardized CPT in normal subjects. Rewarming time in the CPT was significantly lower in those subjects classified as vascular Stockholm stage 0 compared with Stockholm stages 1-3 combined, but did not discriminate between the stages of abnormality. Using the suggested cut-off in the CPT test, the sensitivity and specificity were calculated as 43 and 78%, respectively. Receiver operator characteristic analysis suggested that the rewarming time of highest accuracy gave a sensitivity of 66% and specificity of 59%. In 10 miners who reported unilateral hand blanching, there was no significant difference in CPT measurements between blanching and non-blanching hands. Repeat CPT measurements in normal subjects suggested mean differences of 52 and 107 s for each hand, and the Bland-Altman coefficient of repeatability was approximately 600 s for all fingers. Single application of this standardized CPT test may have limited value in diagnosing the vascular component of HAVS in an individual.
Improving clinical cognitive testing
Gale, Seth A.; Barrett, A.M.; Boeve, Bradley F.; Chatterjee, Anjan; Coslett, H. Branch; D'Esposito, Mark; Finney, Glen R.; Gitelman, Darren R.; Hart, John J.; Lerner, Alan J.; Meador, Kimford J.; Pietras, Alison C.; Voeller, Kytja S.; Kaufer, Daniel I.
2015-01-01
Objective: To evaluate the evidence basis of single-domain cognitive tests frequently used by behavioral neurologists in an effort to improve the quality of clinical cognitive assessment. Methods: Behavioral Neurology Section members of the American Academy of Neurology were surveyed about how they conduct clinical cognitive testing, with a particular focus on the Neurobehavioral Status Exam (NBSE). In contrast to general screening cognitive tests, an NBSE consists of tests of individual cognitive domains (e.g., memory or language) that provide a more comprehensive diagnostic assessment. Workgroups for each of 5 cognitive domains (attention, executive function, memory, language, and spatial cognition) conducted evidence-based reviews of frequently used tests. Reviews focused on suitability for office-based clinical practice, including test administration time, accessibility of normative data, disease populations studied, and availability in the public domain. Results: Demographic and clinical practice data were obtained from 200 respondents who reported using a wide range of cognitive tests. Based on survey data and ancillary information, between 5 and 15 tests in each cognitive domain were reviewed. Within each domain, several tests are highlighted as being well-suited for an NBSE. Conclusions: We identified frequently used single-domain cognitive tests that are suitable for an NBSE to help make informed choices about clinical cognitive assessment. Some frequently used tests have limited normative data or have not been well-studied in common neurologic disorders. Utilizing standardized cognitive tests, particularly those with normative data based on the individual's age and educational level, can enhance the rigor and utility of clinical cognitive assessment. PMID:26163433
Investigation of a L1-optimized choke ring ground plane for a low-cost GPS receiver-system
NASA Astrophysics Data System (ADS)
Zhang, Li; Schwieger, Volker
2018-01-01
Besides the geodetic dual-frequency GNSS receivers-systems (receiver and antenna), there are also low-cost single-frequency GPS receiver-systems. The multipath effect is a limiting factor of accuracy for both geodetic dual-frequency and low-cost single-frequency GPS receivers. And the multipath effect is for the short baselines dominating error (typical for the monitoring in Engineering Geodesy). So accuracy and reliability of GPS measurement for monitoring can be improved by reducing the multipath signal. In this paper, the self-constructed L1-optimized choke ring ground plane (CR-GP) is applied to reduce the multipath signal. Its design will be described and its performance will be investigated. The results show that the introduced low-cost single-frequency GPS receiver-system, which contains the Ublox LEA-6T single-frequency GPS receiver and Trimble Bullet III antenna with a self-constructed L1-optimized CR-GP, can reach standard deviations of 3 mm in east, 5 mm in north and 9 mm in height in the test field which has many reflectors. This accuracy is comparable with the geodetic dual-frequency GNSS receiver-system. The improvement of the standard deviation of the measurement using the CR-GP is about 50 % and 35 % compared to the used antenna without shielding and with flat ground plane respectively.
Variation in caffeine concentration in single coffee beans.
Fox, Glen P; Wu, Alex; Yiran, Liang; Force, Lesleigh
2013-11-13
Twenty-eight coffee samples from around the world were tested for caffeine levels to develop near-infrared reflectance spectroscopy (NIRS) calibrations for whole and ground coffee. Twenty-five individual beans from five of those coffees were used to develop a NIRS calibration for caffeine concentration in single beans. An international standard high-performance liquid chromatography method was used to analyze for caffeine content. Coffee is a legal stimulant and possesses a number of heath properties. However, there is variation in the level of caffeine in brewed coffee and other caffeinated beverages. Being able to sort beans on the basis of caffeine concentration will improve quality control in the level of caffeine in those beverages. The range in caffeine concentration was from 0.01 mg/g (decaffeinated coffee) to 19.9 mg/g (Italian coffee). The majority of coffees were around 10.0-12.0 mg/g. The NIRS results showed r(2) values for bulk unground and ground coffees were >0.90 with standard errors <2 mg/g. For the single-bean calibration the r(2) values were between 0.85 and 0.93 with standard errors of cross validation of 0.8-1.6 mg/g depending upon calibration. The results showed it was possible to develop NIRS calibrations to estimate the caffeine concentration of individual coffee beans. One application of this calibration could be sorting beans on caffeine concentration to provide greater quality control for high-end markets. Furthermore, bean sorting may open new markets for novel coffee products.
Demystifying the Clinical Diagnosis of Greater Trochanteric Pain Syndrome in Women.
Ganderton, Charlotte; Semciw, Adam; Cook, Jill; Pizzari, Tania
2017-06-01
To evaluate the diagnostic accuracy of 10 clinical tests that can be used in the diagnosis of greater trochanteric pain syndrome (GTPS) in women, and to compare these clinical tests to magnetic resonance imaging (MRI) findings. Twenty-eight participants with GTPS (49.5 ± 22.0 years) and 18 asymptomatic participants (mean age ± standard deviation [SD], 52.5 ± 22.8 years) were included. A blinded physiotherapist performed 10 pain provocation tests potentially diagnostic for GTPS-palpation of the greater trochanter, resisted external derotation test, modified resisted external derotation test, standard and modified Ober's tests, Patrick's or FABER test, resisted hip abduction, single-leg stance test, and the resisted hip internal rotation test. A sample of 16 symptomatic and 17 asymptomatic women undertook a hip MRI scan. Gluteal tendons were evaluated and categorized as no pathology, mild tendinosis, moderate tendinosis/partial tear, or full-thickness tear. Clinical test analyses show high specificity, high positive predictive value, low to moderate sensitivity, and negative predictive value for most clinical tests. All symptomatic and 88% of asymptomatic participants had pathological gluteal tendon changes on MRI, from mild tendinosis to full-thickness tear. The study found the Patrick's or FABER test, palpation of the greater trochanter, resisted hip abduction, and the resisted external derotation test to have the highest diagnostic test accuracy for GTPS. Tendon pathology on MRI is seen in both symptomatic and asymptomatic women.
Effect of Tribulus terrestris on Haloperidol-induced Catalepsy in Mice.
Nishchal, B S; Rai, S; Prabhu, M N; Ullal, Sheetal D; Rajeswari, S; Gopalakrishna, H N
2014-01-01
Haloperidol, an antipsychotic drug, leads to the development of a behavioural state called catalepsy, in which the animal is not able to correct an externally imposed posture. In the present study we have attempted to evaluate the anticataleptic effect of Tribulus terrestris on haloperidol-induced catalepsy in albino mice. Mice were allocated to four groups, each group containing six animals. Both, the test drug, Tribulus terrestris and the standard drug trihexyphenidyl were uniformly suspended in 1% gum acacia solution. Catalepsy was induced in mice with haloperidol (1.0 mg/kg, intraperitoneally). The first group received the vehicle (10 ml/kg, orally), the second group received trihexyphenidyl (10 mg/kg, orally) and the remaining two groups received Tribulus terrestris (100, 200 mg/kg, orally). The animals were assessed after single and repeated dose administration for ten days, 30 min prior to haloperidol, using standard bar test. The result of the present study demonstrates Tribulus terrestris has a protective effect against haloperidol-induced catalepsy, which is comparable to the standard drug used for the same purpose. Our study indicates Tribulus terrestris can be used to prevent haloperidol-induced extrapyramidal side effects.
Implementation and verification of global optimization benchmark problems
NASA Astrophysics Data System (ADS)
Posypkin, Mikhail; Usov, Alexander
2017-12-01
The paper considers the implementation and verification of a test suite containing 150 benchmarks for global deterministic box-constrained optimization. A C++ library for describing standard mathematical expressions was developed for this purpose. The library automate the process of generating the value of a function and its' gradient at a given point and the interval estimates of a function and its' gradient on a given box using a single description. Based on this functionality, we have developed a collection of tests for an automatic verification of the proposed benchmarks. The verification has shown that literary sources contain mistakes in the benchmarks description. The library and the test suite are available for download and can be used freely.
Correcting a Fundamental Flaw in the Paradigm for Antimicrobial Susceptibility Testing.
Ersoy, Selvi C; Heithoff, Douglas M; Barnes, Lucien; Tripp, Geneva K; House, John K; Marth, Jamey D; Smith, Jeffrey W; Mahan, Michael J
2017-06-01
The emergence and prevalence of antibiotic-resistant bacteria are an increasing cause of death worldwide, resulting in a global 'call to action' to avoid receding into an era lacking effective antibiotics. Despite the urgency, the healthcare industry still relies on a single in vitro bioassay to determine antibiotic efficacy. This assay fails to incorporate environmental factors normally present during host-pathogen interactions in vivo that significantly impact antibiotic efficacy. Here we report that standard antimicrobial susceptibility testing (AST) failed to detect antibiotics that are in fact effective in vivo; and frequently identified antibiotics that were instead ineffective as further confirmed in mouse models of infection and sepsis. Notably, AST performed in media mimicking host environments succeeded in identifying specific antibiotics that were effective in bacterial clearance and host survival, even though these same antibiotics failed in results using standard test media. Similarly, our revised media further identified antibiotics that were ineffective in vivo despite passing the AST standard for clinical use. Supplementation of AST medium with sodium bicarbonate, an abundant in vivo molecule that stimulates global changes in bacterial structure and gene expression, was found to be an important factor improving the predictive value of AST in the assignment of appropriate therapy. These findings have the potential to improve the means by which antibiotics are developed, tested, and prescribed. Copyright © 2017 The Author(s). Published by Elsevier B.V. All rights reserved.
Conen, Silke; Theunissen, Eef L; Van Oers, Anita C M; Valiente, Román; Ramaekers, Johannes G
2011-11-01
Bilastine is a new second-generation H1 antagonist. Although bilastine has been demonstrated to produce little or no performance impairment in laboratory tests, it cannot be excluded that it produces impairments in real-life performance such as driving. This study aims to assess the effects of two doses of bilastine (20 and 40 mg) on actual driving after single and repeated administration. Hydroxyzine 50 mg was included as an active control. Twenty-two participants (11 females, 11 males) were tested in a placebo-controlled, randomized, double-blind, four-way cross-over design. Participants were treated with once-daily doses for eight consecutive days. On day 1 and 8 of each treatment period participants performed an actual highway driving test. The primary variable was standard deviation of lateral position (SDLP), a measure of weaving. Results demonstrated that hydroxyzine significantly increased SDLP on days 1 and 8 of treatment. Bilastine did not affect SDLP. It is concluded that hydroxyzine produces severe driving impairment after single doses and that this impairment only partly mitigates over time due to a lack of complete tolerance. Bilastine did not produce any driving impairment after single and repeated doses and can be safely used in traffic in doses up to 40 mg.
Comprehensive genetic testing for female and male infertility using next-generation sequencing.
Patel, Bonny; Parets, Sasha; Akana, Matthew; Kellogg, Gregory; Jansen, Michael; Chang, Chihyu; Cai, Ying; Fox, Rebecca; Niknazar, Mohammad; Shraga, Roman; Hunter, Colby; Pollock, Andrew; Wisotzkey, Robert; Jaremko, Malgorzata; Bisignano, Alex; Puig, Oscar
2018-05-19
To develop a comprehensive genetic test for female and male infertility in support of medical decisions during assisted reproductive technology (ART) protocols. We developed a next-generation sequencing (NGS) gene panel consisting of 87 genes including promoters, 5' and 3' untranslated regions, exons, and selected introns. In addition, sex chromosome aneuploidies and Y chromosome microdeletions were analyzed concomitantly using the same panel. The NGS panel was analytically validated by retrospective analysis of 118 genomic DNA samples with known variants in loci representative of female and male infertility. Our results showed analytical accuracy of > 99%, with > 98% sensitivity for single-nucleotide variants (SNVs) and > 91% sensitivity for insertions/deletions (indels). Clinical sensitivity was assessed with samples containing variants representative of male and female infertility, and it was 100% for SNVs/indels, CFTR IVS8-5T variants, sex chromosome aneuploidies, and copy number variants (CNVs) and > 93% for Y chromosome microdeletions. Cost analysis shows potential savings when comparing this single NGS assay with the standard approach, which includes multiple assays. A single, comprehensive, NGS panel can simplify the ordering process for healthcare providers, reduce turnaround time, and lower the overall cost of testing for genetic assessment of infertility in females and males, while maintaining accuracy.
Validation of Proposed Metrics for Two-Body Abrasion Scratch Test Analysis Standards
NASA Technical Reports Server (NTRS)
Kobrick, Ryan L.; Klaus, David M.; Street, Kenneth W., Jr.
2011-01-01
The objective of this work was to evaluate a set of standardized metrics proposed for characterizing a surface that has been scratched from a two-body abrasion test. This is achieved by defining a new abrasion region termed Zone of Interaction (ZOI). The ZOI describes the full surface profile of all peaks and valleys, rather than just measuring a scratch width as currently defined by the ASTM G 171 Standard. The ZOI has been found to be at least twice the size of a standard width measurement, in some cases considerably greater, indicating that at least half of the disturbed surface area would be neglected without this insight. The ZOI is used to calculate a more robust data set of volume measurements that can be used to computationally reconstruct a resultant profile for detailed analysis. Documenting additional changes to various surface roughness parameters also allows key material attributes of importance to ultimate design applications to be quantified, such as depth of penetration and final abraded surface roughness. Data are presented to show that different combinations of scratch tips and abraded materials can actually yield the same scratch width, but result in different volume displacement or removal measurements and therefore, the ZOI method is more discriminating than the ASTM method scratch width. Furthermore, by investigating the use of custom scratch tips for our specific needs, the usefulness of having an abrasion metric that can measure the displaced volume in this standardized manner, and not just by scratch width alone, is reinforced. This benefit is made apparent when a tip creates an intricate contour having multiple peaks and valleys within a single scratch. This work lays the foundation for updating scratch measurement standards to improve modeling and characterization of three-body abrasion test results.
NASA Astrophysics Data System (ADS)
Warheit, David B.; Donner, E. Maria
2015-06-01
A recent review article critically assessed the effectiveness of published research articles in nanotoxicology to meaningfully address health and safety issues for workers and consumers. The main conclusions were that, based on a number of flaws in study designs, the potential risk from exposures to nanomaterials is highly exaggerated, and that no ‘nano-specific’ adverse effects, different from exposures to bulk particles, have been convincingly demonstrated. In this brief editorial we focus on a related tangential issue which potentially compromises the integrity of basic risk science. We note that some single investigation studies report specious toxicity findings, which make the conclusions more alarming and attractive and publication worthy. In contrast, the standardized, carefully conducted, ‘guideline study results’ are often ignored because they can frequently report no adverse effects; and as a consequence are not considered as novel findings for publication purposes, and therefore they are never considered as newsworthy in the popular press. Yet it is the Organization for Economic Cooperation and Development (OECD) type test guideline studies that are the most reliable for conducting risk assessments. To contrast these styles and approaches, we present the results of a single study which reports high toxicological effects in rats following low-dose, short-term oral exposures to nanoscale titanium dioxide particles concomitant with selective investigative analyses. Alternatively, the findings of OECD test guideline 408, standardized guideline oral toxicity studies conducted for 90 days at much higher doses (1000 mg kg-1) in male and female rats demonstrated no adverse effects following a very thorough and complete clinical chemical, as well as histopathological evaluation of all of the relevant organs in the body. This discrepancy in study findings is not reconciled by the fact that several biokinetic studies in rats and humans demonstrate little or no uptake of nanoscale or pigment-grade TiO2 particles following oral exposures. We conclude that to develop a competent risk assessment profile, results derived from standardized, guideline-type studies, and even ‘no effect’ study findings provide critically useful input for assessing safe levels of exposure; and should, in principle, be readily acceptable for publication in peer-reviewed toxicology journals. This is a necessary prerequisite for developing a complete dataset for risk assessment determinations.
Influence of direct or indirect contact for the cytotoxicity and blood compatibility of spider silk.
Kuhbier, J W; Coger, V; Mueller, J; Liebsch, C; Schlottmann, F; Bucan, V; Vogt, P M; Strauss, S
2017-08-01
Spider silk became one of the most-researched biomaterials in the last years due to its unique mechanical strength and most favourable chemical composition for tissue engineering purposes. However, standardized analysis of cytocompatibility is missing. Therefore, the aim of this study was to investigate hemolysis, cytotoxicity of native spider silk as well as influences on the cell culture medium. Changes of cell culture medium composition, osmolarity as well as glucose and lactate content were determined via ELISA measurement. Possible hemolysis and cytotoxicity in vitro of spider silk were performed via measurement of hemoglobin release of human red blood cells or relative metabolic activity of L929 fibroblasts, respectively, according to international standard procedures. In ELISA measurement, no significant changes in medium composition could be found in this study. Spider silk was not hemolytic in direct and indirect testing. However, a borderline cytotoxicity according to definitions was found in indirect cytotoxicity testing. Nevertheless, in direct cytotoxicity testing, relative metabolic activity measurement revealed that spider silk is not cytotoxic under these conditions. This is the first study to conduct standardized tests regarding cytotoxicity and hemolysis of native spider silk, which might be considered inert in cell culture. As neither hemolysis nor cytotoxicity was found in direct contact in standardized procedures, safety in biomedical applications may be assumed. The indirect cytotoxicity seems to play a minor role in vivo. However, a borderline toxicity was revealed, suggesting potential leachables not yet identified. Displays one of the weaving frames used in this study after seeding with the single drop technique described herein.
Khan, Wasif Ali; Saha, Debasish; Ahmed, Sabeena; Salam, Mohammed Abdus; Bennish, Michael Louis
2015-01-01
We identified a poor clinical response to treatment of cholera with a single 1 g dose of ciprofloxacin, a standard treatment for cholera. To determine reasons for the poor response and better therapeutic approaches we examined the minimal inhibitor concentration (MIC, n = 275) and disc-diffusion zone sizes (n = 205) for ciprofloxacin and nalidixic acid of V. cholerae O1 strains isolated in Bangladesh from 1994 to 2012, and reexamined data from 161 patients infected with Vibrio cholerae O1 recruited in four clinical trials who received single- or multiple-dose ciprofloxacin for treatment of cholera and compared their clinical response to the V. cholerae O1 susceptibility. Although all 275 isolates of V. cholerae O1 remained susceptible to ciprofloxacin using standard MIC and disc-diffusion thresholds, the MIC90 to ciprofloxacin increased from 0.010 in 1994 to 0.475 μgm/ml in 2012. Isolates became frankly resistant to nalidixic with the MIC90 increasing from 21 μgm/ml in 1994 to >256 μgm/ml and 166 of 205 isolates from 1994 to 2005 being frankly resistant using disc-diffusion testing. Isolates resistant to nalidixic acid by disc-diffusion testing had a median ciprofloxacin MIC of 0.190 μgm/ml (10th-90th centiles 0.022 to 0.380); nalidixic acid-susceptible isolates had a median ciprofloxacin MIC of 0.002 (0.002 to 0.012).The rate of clinical success with single-dose ciprofloxacin treatment for nalidixic acid-susceptible strains was 94% (61 of 65 patients) and bacteriologic success 97% (63/65) compared to 18% (12/67) and 8% (5/67) respectively with nalidixic acid-resistant strains (P<0.001 for both comparisons). Multiple-dose treatment with ciprofloxacin had 86% and 100% clinical and bacteriologic success rates respectively in patients infected with nalidixic acid-susceptible strains of V. cholerae O1 compared to clinical success 67% and bacteriologic success 60% with nalidixic acid-resistant strains. Single-dose ciprofloxacin is not effective for treating cholera caused by V. cholerae O1 with diminished susceptibility to ciprofloxacin, and nalidixic acid disc-diffusion testing effectively screens for such isolates.
Lipsett, Susan C; Branda, John A; McAdam, Alexander J; Vernacchio, Louis; Gordon, Caroline D; Gordon, Catherine R; Nigrovic, Lise E
2016-10-01
The commercially-available C6 Lyme enzyme immunoassay (EIA) has been approved to replace the standard whole-cell sonicate EIA as a first-tier test for the diagnosis of Lyme disease and has been suggested as a stand-alone diagnostic. However, the C6 EIA has not been extensively studied in pediatric patients undergoing evaluation for Lyme disease. We collected discarded serum samples from children and adolescents (aged ≤21 years) undergoing conventional 2-tiered testing for Lyme disease at a single hospital-based clinical laboratory located in an area endemic for Lyme disease. We performed a C6 EIA on all collected specimens, followed by a supplemental immunoblot if the C6 EIA result was positive but the whole-cell sonicate EIA result was negative. We defined a case of Lyme disease as either a clinician-diagnosed erythema migrans lesion or a positive standard 2-tiered serologic result in a patient with symptoms compatible with Lyme disease. We then compared the performance of the C6 EIA alone and as a first-tier test followed by immunoblot, with that of standard 2-tiered serology for the diagnosis of Lyme disease. Of the 944 specimens collected, 114 (12%) were from patients with Lyme disease. The C6 EIA alone had sensitivity similar to that of standard 2-tiered testing (79.8% vs 81.6% for standard 2-tiered testing; P = .71) with slightly lower specificity (94.2% vs 98.8% 2; P < .002). Addition of a supplemental immunoblot improved the specificity of the C6 EIA to 98.6%. For children and adolescents undergoing evaluation for Lyme disease, the C6 EIA could guide initial clinical decision making, although a supplemental immunoblot should still be performed. © The Author 2016. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail journals.permissions@oup.com.
Michiels, Bart; Heyvaert, Mieke; Onghena, Patrick
2018-04-01
The conditional power (CP) of the randomization test (RT) was investigated in a simulation study in which three different single-case effect size (ES) measures were used as the test statistics: the mean difference (MD), the percentage of nonoverlapping data (PND), and the nonoverlap of all pairs (NAP). Furthermore, we studied the effect of the experimental design on the RT's CP for three different single-case designs with rapid treatment alternation: the completely randomized design (CRD), the randomized block design (RBD), and the restricted randomized alternation design (RRAD). As a third goal, we evaluated the CP of the RT for three types of simulated data: data generated from a standard normal distribution, data generated from a uniform distribution, and data generated from a first-order autoregressive Gaussian process. The results showed that the MD and NAP perform very similarly in terms of CP, whereas the PND performs substantially worse. Furthermore, the RRAD yielded marginally higher power in the RT, followed by the CRD and then the RBD. Finally, the power of the RT was almost unaffected by the type of the simulated data. On the basis of the results of the simulation study, we recommend at least 20 measurement occasions for single-case designs with a randomized treatment order that are to be evaluated with an RT using a 5% significance level. Furthermore, we do not recommend use of the PND, because of its low power in the RT.
[How good are clinical investigative procedures for diagnosing meniscus lesions?].
Jerosch, J; Riemer, S
2004-06-01
The purpose of this study was to evaluate different clinical meniscus tests. During 13 months we evaluated 64 patients with a suspected meniscus lesion in a prospective study. The age ranged from 16 to 76 years (average: 38.5 years). 66 % were male patients. Between the clinical examination and the arthroscopy there was no additional trauma to the knee. All patients were clinically examined in a standard manner by two independent orthopaedic surgeons. Clinical findings of the menisci were documented according to 12 well-described and commonly used meniscus tests. The arthroscopy was performed by a single surgeon who was not aware of the results of the clinical examination. This surgeon documented the intraarticular findings in a standardized operating report. A meniscus lesion/degeneration was documented when this was evident either by inspection or by palpation. The results showed either clinical meniscus tests with a high specificity and a low sensitivity or tests with a high sensitivity, but only a low specificity. We were not able to identify meniscus tests which showed both a high sensitivity and a high specificity. Even with access to MRI the clinical findings in knee joint with injured menisci still have a high diagnostic value. However, it seems to be necessary to combine different tests.
Precision Spectroscopy on Single Cold Trapped Molecular Nitrogen Ions
NASA Astrophysics Data System (ADS)
Hegi, Gregor; Najafian, Kaveh; Germann, Matthias; Sergachev, Ilia; Willitsch, Stefan
2016-06-01
The ability to precisely control and manipulate single cold trapped particles has enabled spectroscopic studies on narrow transitions of ions at unprecedented levels of precision. This has opened up a wide range of applications, from tests of fundamental physical concepts, e.g., possible time-variations of fundamental constants, to new and improved frequency standards. So far most of these experiments have concentrated on atomic ions. Recently, however, attention has also been focused on molecular species, and molecular nitrogen ions have been identified as promising candidates for testing a possible time-variation of the proton/electron mass ratio. Here, we report progress towards precision-spectroscopic studies on dipole-forbidden vibrational transitions in single trapped N2+ ions. Our approach relies on the state-selective generation of single N2+ ions, subsequent infrared excitation using high intensity, narrow-band quantum-cascade lasers and a quantum-logic scheme for non-destructive state readout. We also characterize processes limiting the state lifetimes in our experiment, which impair the measurement fidelity. P. O. Schmidt et. al., Science 309 (2005), 749. M. Kajita et. al., Phys. Rev. A 89 (2014), 032509 M. Germann , X. Tong, S. Willitsch, Nature Physics 10 (2014), 820. X. Tong, A. Winney, S. Willitsch, Phys. Rev. Lett. 105 (2010), 143001
Lenehan, Megan E; Summers, Mathew J; Saunders, Nichole L; Summers, Jeffery J; Vickers, James C
2016-04-01
The Cambridge Neuropsychological Test Automated Battery (CANTAB) is a semiautomated computer interface for assessing cognitive function. We examined whether CANTAB tests measured specific cognitive functions, using established neuropsychological tests as a reference point. A sample of 500 healthy older (M = 60.28 years, SD = 6.75) participants in the Tasmanian Healthy Brain Project completed battery of CANTAB subtests and standard paper-based neuropsychological tests. Confirmatory factor analysis identified four factors: processing speed, verbal ability, episodic memory, and working memory. However, CANTAB tests did not consistently load onto the cognitive domain factors derived from traditional measures of the same function. These results indicate that five of the six CANTAB subtests examined did not load onto single cognitive functions. These CANTAB tests may lack the sensitivity to measure discrete cognitive functions in healthy populations or may measure other cognitive domains not included in the traditional neuropsychological battery. © The Author(s) 2015.
2017-07-01
8-3 8.4.1 Characteristics of a Singular Composite Output Signal ...................................... 8-3 8.5 Single Bus Track Spread Recording ...Format .............................................................. 8-5 8.5.1 Single Bus Recording Technique Characteristics...check FCS frame check sequence HDDR high-density digital recording MIL-STD Military Standard msb most significant bit PCM pulse code modulation
Are Caribbean reef sharks, Carcharhinus perezi, able to perceive human body orientation?
Ritter, Erich K; Amin, Raid
2014-05-01
The present study examines the potential capability of Caribbean reef sharks to perceive human body orientation, as well as discussing the sharks' swimming patterns in a person's vicinity. A standardized video method was used to record the scenario of single SCUBA divers kneeling in the sand and the approach patterns of sharks, combined with a control group of two divers kneeling back-to-back. When approaching a single test-subject, significantly more sharks preferred to swim outside the person's field of vision. The results suggest that these sharks are able to identify human body orientation, but the mechanisms used and factors affecting nearest distance of approach remain unclear.
Metal surface corrosion grade estimation from single image
NASA Astrophysics Data System (ADS)
Chen, Yijun; Qi, Lin; Sun, Huyuan; Fan, Hao; Dong, Junyu
2018-04-01
Metal corrosion can cause many problems, how to quickly and effectively assess the grade of metal corrosion and timely remediation is a very important issue. Typically, this is done by trained surveyors at great cost. Assisting them in the inspection process by computer vision and artificial intelligence would decrease the inspection cost. In this paper, we propose a dataset of metal surface correction used for computer vision detection and present a comparison between standard computer vision techniques by using OpenCV and deep learning method for automatic metal surface corrosion grade estimation from single image on this dataset. The test has been performed by classifying images and calculating the accuracy for the two different approaches.
Evaluation of Fuel Character Effects on the F101 Engine Combustion System
1979-06-01
inner liner. The dome, outer liner, and outer cowl are a single welded assembly. Provisions for differential expansion between the fuel injectors and...Electric smoke measurement console shown in Figure 20 contains standard test equipment which fully conforms to SAE ARP 1179 (Reference 5). Smoke spot...spot samples are later delivered to the data processing area, where the reflectances are measured and the SAE Smoke Number is calculated. The gaseous
Metapopulation Structure and Dynamics of an Endangered Butterfly
2010-01-01
the yearly variation of between-generation population change. We utilized weather data from the closest accessible NOAA weather station (43◦56′N/90◦49...patterns in the population dynamic, and tested for density-dependent growth and weather factors as potential explanatory factors of the yearly variation...followed a standard protocol including avoiding inclement weather con- ditions (Wilder 1999) and about 95% of the survey data were collected by a single
Quantitative Improvements in Hop Test Scores After a 6-Week Neuromuscular Training Program.
Meierbachtol, Adam; Rohman, Eric; Paur, Eric; Bottoms, John; Tompkins, Marc
2016-09-12
In patients who have undergone anterior cruciate ligament reconstruction (ACLR), the effect of neuromuscular re-education (NMR) programs on standard hop tests outcomes, including limb symmetry indices (LSIs), is unknown. Both legs will show improvement in hop test-measured units after neuromuscular training, but the involved leg will show relatively greater improvement leading to improved limb symmetry. Patients younger than 18 years will show more improvement than patients who are older. Retrospective cohort study. Level 3. Patients self-selected their participation in this NMR program, which was completed after traditional outpatient physical therapy. Pre- and post-hop test scores were recorded as the primary outcome measure. Seventy-one patients met the inclusion criteria and completed hop testing. Overall, the involved leg showed significant improvements (pretest/posttest) for single-leg hop (138.30 cm/156.89 cm), triple crossover hop (370.05 cm/423.11 cm), and timed hop (2.21 s/1.99 s). Similarly, on the uninvolved leg, improvements were seen for the single-leg hop (159.30 cm/171.87 cm) and triple crossover hop (427.50 cm/471.27 cm). Overall mean limb symmetry improved across all 4 hop tests, but there was significant improvement only on the single-leg hop (87% pretest to 92% posttest). Patients younger than 18 years showed mean significant LSI improvement on the triple crossover hop. Utilizing an intensive 6-week NMR program after ACLR prior to return to sport can improve quantitative hop test measurements. Patients younger than 18 years had greater improvement than those 18 years and older. Advanced NMR programs can be successfully utilized in the postoperative ACLR setting to improve quantitative limb symmetry. © 2016 The Author(s).
Detecting Gear Tooth Fatigue Cracks in Advance of Complete Fracture
NASA Technical Reports Server (NTRS)
Zakrajsek, James J.; Lewicki, David G.
1996-01-01
Results of using vibration-based methods to detect gear tooth fatigue cracks are presented. An experimental test rig was used to fail a number of spur gear specimens through bending fatigue. The gear tooth fatigue crack in each test was initiated through a small notch in the fillet area of a tooth on the gear. The primary purpose of these tests was to verify analytical predictions of fatigue crack propagation direction and rate as a function of gear rim thickness. The vibration signal from a total of three tests was monitored and recorded for gear fault detection research. The damage consisted of complete rim fracture on the two thin rim gears and single tooth fracture on the standard full rim test gear. Vibration-based fault detection methods were applied to the vibration signal both on-line and after the tests were completed. The objectives of this effort were to identify methods capable of detecting the fatigue crack and to determine how far in advance of total failure positive detection was given. Results show that the fault detection methods failed to respond to the fatigue crack prior to complete rim fracture in the thin rim gear tests. In the standard full rim gear test all of the methods responded to the fatigue crack in advance of tooth fracture; however, only three of the methods responded to the fatigue crack in the early stages of crack propagation.
Toriihara, Akira; Daisaki, Hiromitsu; Yamaguchi, Akihiro; Yoshida, Katsuya; Isogai, Jun; Tateishi, Ukihide
2018-05-21
Recently, semiquantitative analysis using standardized uptake value (SUV) has been introduced in bone single-photon emission computed tomography/computed tomography (SPECT/CT). Our purposes were to apply SUV-based semiquantitative analytic method for gallium-67 (Ga)-citrate SPECT/CT and to evaluate correlation between SUV of physiological uptake and blood test results in representative organs. The accuracy of semiquantitative method was validated using an National Electrical Manufacturers Association body phantom study (radioactivity ratio of sphere : background=4 : 1). Thereafter, 59 patients (34 male and 25 female; mean age, 66.9 years) who had undergone Ga-citrate SPECT/CT were retrospectively enrolled in the study. A mean SUV of physiological uptake was calculated for the following organs: the lungs, right atrium, liver, kidneys, spleen, gluteal muscles, and bone marrow. The correlation between physiological uptakes and blood test results was evaluated using Pearson's correlation coefficient. The phantom study revealed only 1% error between theoretical and actual SUVs in the background, suggesting the sufficient accuracy of scatter and attenuation corrections. However, a partial volume effect could not be overlooked, particularly in small spheres with a diameter of less than 28 mm. The highest mean SUV was observed in the liver (range: 0.44-4.64), followed by bone marrow (range: 0.33-3.60), spleen (range: 0.52-2.12), and kidneys (range: 0.42-1.45). There was no significant correlation between hepatic uptake and liver function, renal uptake and renal function, or bone marrow uptake and blood cell count (P>0.05). The physiological uptake in Ga-citrate SPECT/CT can be represented as SUVs, which are not significantly correlated with corresponding blood test results.
Qualification and Selection of Flight Diode Lasers for Space Applications
NASA Technical Reports Server (NTRS)
Liebe, Carl C.; Dillon, Robert P.; Gontijo, Ivair; Forouhar, Siamak; Shapiro, Andrew A.; Cooper, Mark S.; Meras, Patrick L.
2010-01-01
The reliability and lifetime of laser diodes is critical to space missions. The Nuclear Spectroscopic Telescope Array (NuSTAR) mission includes a metrology system that is based upon laser diodes. An operational test facility has been developed to qualify and select, by mission standards, laser diodes that will survive the intended space environment and mission lifetime. The facility is situated in an electrostatic discharge (ESD) certified clean-room and consist of an enclosed temperature-controlled stage that can accommodate up to 20 laser diodes. The facility is designed to characterize a single laser diode, in addition to conducting laser lifetime testing on up to 20 laser diodes simultaneously. A standard laser current driver is used to drive a single laser diode. Laser diode current, voltage, power, and wavelength are measured for each laser diode, and a method of selecting the most adequate laser diodes for space deployment is implemented. The method consists of creating histograms of laser threshold currents, powers at a designated current, and wavelengths at designated power. From these histograms, the laser diodes that illustrate a performance that is outside the normal are rejected and the remaining lasers are considered spaceborne candidates. To perform laser lifetime testing, the facility is equipped with 20 custom laser drivers that were designed and built by California Institute of Technology specifically to drive NuSTAR metrology lasers. The laser drivers can be operated in constant-current mode or alternating-current mode. Situated inside the enclosure, in front of the laser diodes, are 20 power-meter heads to record laser power throughout the duration of lifetime testing. Prior to connecting a laser diode to the current source for characterization and lifetime testing, a background program is initiated to collect current, voltage, and resistance. This backstage data collection enables the operational test facility to have full laser diode traceablity.
Standardized protocols for quality control of MRM-based plasma proteomic workflows.
Percy, Andrew J; Chambers, Andrew G; Smith, Derek S; Borchers, Christoph H
2013-01-04
Mass spectrometry (MS)-based proteomics is rapidly emerging as a viable technology for the identification and quantitation of biological samples, such as human plasma--the most complex yet commonly employed biofluid in clinical analyses. The transition from a qualitative to quantitative science is required if proteomics is going to successfully make the transition to a clinically useful technique. MS, however, has been criticized for a lack of reproducibility and interlaboratory transferability. Currently, the MS and plasma proteomics communities lack standardized protocols and reagents to ensure that high-quality quantitative data can be accurately and precisely reproduced by laboratories across the world using different MS technologies. Toward addressing this issue, we have developed standard protocols for multiple reaction monitoring (MRM)-based assays with customized isotopically labeled internal standards for quality control of the sample preparation workflow and the MS platform in quantitative plasma proteomic analyses. The development of reference standards and their application to a single MS platform is discussed herein, along with the results from intralaboratory tests. The tests highlighted the importance of the reference standards in assessing the efficiency and reproducibility of the entire bottom-up proteomic workflow and revealed errors related to the sample preparation and performance quality and deficits of the MS and LC systems. Such evaluations are necessary if MRM-based quantitative plasma proteomics is to be used in verifying and validating putative disease biomarkers across different research laboratories and eventually in clinical laboratories.
Design and test of data acquisition systems for the Medipix2 chip based on PC standard interfaces
NASA Astrophysics Data System (ADS)
Fanti, Viviana; Marzeddu, Roberto; Piredda, Giuseppina; Randaccio, Paolo
2005-07-01
We describe two readout systems for hybrid detectors using the Medipix2 single photon counting chip, developed within the Medipix Collaboration. The Medipix2 chip (256×256 pixels, 55 μm pitch) has an active area of about 2 cm 2 and is bump-bonded to a pixel semiconductor array of silicon or other semiconductor material. The readout systems we are developing are based on two widespread standard PC interfaces: parallel port and USB (Universal Serial Bus) version 1.1. The parallel port is the simplest PC interface even if slow and the USB is a serial bus interface present nowadays on all PCs and offering good performances.
New methods to quantify the cracking performance of cementitious systems made with internal curing
NASA Astrophysics Data System (ADS)
Schlitter, John L.
The use of high performance concretes that utilize low water-cement ratios have been promoted for use in infrastructure based on their potential to increase durability and service life because they are stronger and less porous. Unfortunately, these benefits are not always realized due to the susceptibility of high performance concrete to undergo early age cracking caused by shrinkage. This problem is widespread and effects federal, state, and local budgets that must maintain or replace deterioration caused by cracking. As a result, methods to reduce or eliminate early age shrinkage cracking have been investigated. Internal curing is one such method in which a prewetted lightweight sand is incorporated into the concrete mixture to provide internal water as the concrete cures. This action can significantly reduce or eliminate shrinkage and in some cases causes a beneficial early age expansion. Standard laboratory tests have been developed to quantify the shrinkage cracking potential of concrete. Unfortunately, many of these tests may not be appropriate for use with internally cured mixtures and only provide limited amounts of information. Most standard tests are not designed to capture the expansive behavior of internally cured mixtures. This thesis describes the design and implementation of two new testing devices that overcome the limitations of current standards. The first device discussed in this thesis is called the dual ring. The dual ring is a testing device that quantifies the early age restrained shrinkage performance of cementitious mixtures. The design of the dual ring is based on the current ASTM C 1581-04 standard test which utilizes one steel ring to restrain a cementitious specimen. The dual ring overcomes two important limitations of the standard test. First, the standard single ring test cannot restrain the expansion that takes place at early ages which is not representative of field conditions. The dual ring incorporates a second restraining ring which is located outside of the sample to provide restraint against expansion. Second, the standard ring test is a passive test that only relies on the autogenous and drying shrinkage of the mixture to induce cracking. The dual ring test can be an active test because it has the ability to vary the temperature of the specimen in order to induce thermal stress and produce cracking. This ability enables the study of the restrained cracking capacity as the mixture ages in order to quantify crack sensitive periods of time. Measurements made with the dual ring quantify the benefits from using larger amounts of internal curing. Mixtures that resupplied internal curing water to match that of chemical shrinkage could sustain three times the magnitude of thermal change before cracking. The second device discussed in this thesis is a large scale slab testing device. This device tests the cracking potential of 15' long by 4" thick by 24" wide slab specimens in an environmentally controlled chamber. The current standard testing devices can be considered small scale and encounter problems when linking their results to the field due to size effects. Therefore, the large scale slab testing device was developed in order to calibrate the results of smaller scale tests to real world field conditions such as a pavement or bridge deck. Measurements made with the large scale testing device showed that the cracking propensity of the internally cured mixtures was reduced and that a significant benefit could be realized.
Clements, William H; Cadmus, Pete; Brinkman, Stephen F
2013-07-02
Field surveys of metal-contaminated streams suggest that some aquatic insects, particularly mayflies (Ephemeroptera) and stoneflies (Plecoptera), are highly sensitive to metals. However, results of single species toxicity tests indicate these organisms are quite tolerant, with LC50 values often several orders of magnitude greater than those obtained using standard test organisms (e.g., cladocerans and fathead minnows). Reconciling these differences is a critical research need, particularly since water quality criteria for metals are based primarily on results of single species toxicity tests. In this research we provide evidence based on community-level microcosm experiments to support the hypothesis that some aquatic insects are highly sensitive to metals. We present results of three experiments that quantified effects of Cu and Zn, alone and in combination, on stream insect communities. EC50 values, defined as the metal concentration that reduced abundance of aquatic insects by 50%, were several orders of magnitude lower than previously published values obtained from single species tests. We hypothesize that the short duration of laboratory toxicity tests and the failure to evaluate effects of metals on sensitive early life stages are the primary factors responsible for unrealistically high LC50 values in the literature. We also observed that Cu alone was significantly more toxic to aquatic insects than the combination of Cu and Zn, despite the fact that exposure concentrations represented theoretically similar toxicity levels. Our results suggest that water quality criteria for Zn were protective of most aquatic insects, whereas Cu was highly toxic to some species at concentrations near water quality criteria. Because of the functional significance of aquatic insects in stream ecosystems and their well-established importance as indicators of water quality, reconciling differences between field and laboratory responses and understanding the mechanisms responsible for variation in sensitivity among metals and metal mixtures is of critical importance.
Martin, Richard M; Donovan, Jenny L; Turner, Emma L; Metcalfe, Chris; Young, Grace J; Walsh, Eleanor I; Lane, J Athene; Noble, Sian; Oliver, Steven E; Evans, Simon; Sterne, Jonathan A C; Holding, Peter; Ben-Shlomo, Yoav; Brindle, Peter; Williams, Naomi J; Hill, Elizabeth M; Ng, Siaw Yein; Toole, Jessica; Tazewell, Marta K; Hughes, Laura J; Davies, Charlotte F; Thorn, Joanna C; Down, Elizabeth; Davey Smith, George; Neal, David E; Hamdy, Freddie C
2018-03-06
Prostate cancer screening remains controversial because potential mortality or quality-of-life benefits may be outweighed by harms from overdetection and overtreatment. To evaluate the effect of a single prostate-specific antigen (PSA) screening intervention and standardized diagnostic pathway on prostate cancer-specific mortality. The Cluster Randomized Trial of PSA Testing for Prostate Cancer (CAP) included 419 582 men aged 50 to 69 years and was conducted at 573 primary care practices across the United Kingdom. Randomization and recruitment of the practices occurred between 2001 and 2009; patient follow-up ended on March 31, 2016. An invitation to attend a PSA testing clinic and receive a single PSA test vs standard (unscreened) practice. Primary outcome: prostate cancer-specific mortality at a median follow-up of 10 years. Prespecified secondary outcomes: diagnostic cancer stage and Gleason grade (range, 2-10; higher scores indicate a poorer prognosis) of prostate cancers identified, all-cause mortality, and an instrumental variable analysis estimating the causal effect of attending the PSA screening clinic. Among 415 357 randomized men (mean [SD] age, 59.0 [5.6] years), 189 386 in the intervention group and 219 439 in the control group were included in the analysis (n = 408 825; 98%). In the intervention group, 75 707 (40%) attended the PSA testing clinic and 67 313 (36%) underwent PSA testing. Of 64 436 with a valid PSA test result, 6857 (11%) had a PSA level between 3 ng/mL and 19.9 ng/mL, of whom 5850 (85%) had a prostate biopsy. After a median follow-up of 10 years, 549 (0.30 per 1000 person-years) died of prostate cancer in the intervention group vs 647 (0.31 per 1000 person-years) in the control group (rate difference, -0.013 per 1000 person-years [95% CI, -0.047 to 0.022]; rate ratio [RR], 0.96 [95% CI, 0.85 to 1.08]; P = .50). The number diagnosed with prostate cancer was higher in the intervention group (n = 8054; 4.3%) than in the control group (n = 7853; 3.6%) (RR, 1.19 [95% CI, 1.14 to 1.25]; P < .001). More prostate cancer tumors with a Gleason grade of 6 or lower were identified in the intervention group (n = 3263/189 386 [1.7%]) than in the control group (n = 2440/219 439 [1.1%]) (difference per 1000 men, 6.11 [95% CI, 5.38 to 6.84]; P < .001). In the analysis of all-cause mortality, there were 25 459 deaths in the intervention group vs 28 306 deaths in the control group (RR, 0.99 [95% CI, 0.94 to 1.03]; P = .49). In the instrumental variable analysis for prostate cancer mortality, the adherence-adjusted causal RR was 0.93 (95% CI, 0.67 to 1.29; P = .66). Among practices randomized to a single PSA screening intervention vs standard practice without screening, there was no significant difference in prostate cancer mortality after a median follow-up of 10 years but the detection of low-risk prostate cancer cases increased. Although longer-term follow-up is under way, the findings do not support single PSA testing for population-based screening. ISRCTN Identifier: ISRCTN92187251.
Su, Chun-Lung; Gardner, Ian A; Johnson, Wesley O
2004-07-30
The two-test two-population model, originally formulated by Hui and Walter, for estimation of test accuracy and prevalence estimation assumes conditionally independent tests, constant accuracy across populations and binomial sampling. The binomial assumption is incorrect if all individuals in a population e.g. child-care centre, village in Africa, or a cattle herd are sampled or if the sample size is large relative to population size. In this paper, we develop statistical methods for evaluating diagnostic test accuracy and prevalence estimation based on finite sample data in the absence of a gold standard. Moreover, two tests are often applied simultaneously for the purpose of obtaining a 'joint' testing strategy that has either higher overall sensitivity or specificity than either of the two tests considered singly. Sequential versions of such strategies are often applied in order to reduce the cost of testing. We thus discuss joint (simultaneous and sequential) testing strategies and inference for them. Using the developed methods, we analyse two real and one simulated data sets, and we compare 'hypergeometric' and 'binomial-based' inferences. Our findings indicate that the posterior standard deviations for prevalence (but not sensitivity and specificity) based on finite population sampling tend to be smaller than their counterparts for infinite population sampling. Finally, we make recommendations about how small the sample size should be relative to the population size to warrant use of the binomial model for prevalence estimation. Copyright 2004 John Wiley & Sons, Ltd.
Theory and experimental validation of SPLASH (Single Panel Lamp and Shroud Helper).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Larsen, Marvin Elwood; Porter, Jason M.
2005-06-01
The radiant heat test facility develops test sets providing well-characterized thermal environments, often representing fires. Many of the components and procedures have become standardized to such an extent that the development of a specialized design tool was appropriate. SPLASH (Single Panel Lamp and Shroud Helper) is that tool. SPLASH is implemented as a user-friendly program that allows a designer to describe a test setup in terms of parameters such as lamp number, power, position, and separation distance. Thermal radiation is the dominant mechanism of heat transfer and the SPLASH model solves a radiation enclosure problem to estimate temperature distributions inmore » a shroud providing the boundary condition of interest. Irradiance distribution on a specified viewing plane is also estimated. This document provides the theoretical development for the underlying model. A series of tests were conducted to characterize SPLASH's ability to analyze lamp and shroud systems. The comparison suggests that SPLASH succeeds as a design tool. Simplifications made to keep the model tractable are demonstrated to result in estimates that are only approximately as uncertain as many of the properties and characteristics of the operating environment.« less
Compressive and Flexural Tests on Adobe Samples Reinforced with Wire Mesh
NASA Astrophysics Data System (ADS)
Jokhio, G. A.; Al-Tawil, Y. M. Y.; Syed Mohsin, S. M.; Gul, Y.; Ramli, N. I.
2018-03-01
Adobe is an economical, naturally available, and environment friendly construction material that offers excellent thermal and sound insulations as well as indoor air quality. It is important to understand and enhance the mechanical properties of this material, where a high degree of variation is reported in the literature owing to lack of research and standardization in this field. The present paper focuses first on the understanding of mechanical behaviour of adobe subjected to compressive stresses as well as flexure and then on enhancing the same with the help of steel wire mesh as reinforcement. A total of 22 samples were tested out of which, 12 cube samples were tested for compressive strength, whereas 10 beams samples were tested for modulus of rupture. Half of the samples in each category were control samples i.e. without wire mesh reinforcement, whereas the remaining half were reinforced with a single layer of wire mesh per sample. It has been found that the compressive strength of adobe increases by about 43% after adding a single layer of wire mesh reinforcement. The flexural response of adobe has also shown improvement with the addition of wire mesh reinforcement.
75 FR 66734 - Proposed Voluntary Product Standard PS 2-10, Structural Plywood
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-29
... to Voluntary Product Standard (PS) 2-04, Performance Standard for Wood-Based Structural-Use Panels... acceptability of wood-based structural-use panels for construction sheathing and single-floor applications. It... acceptability of wood-based structural-use panels for construction sheathing and single- floor application, and...
Fernández, Maria E.; Diamond, Pamela M.; Rakowski, William; Gonzales, Alicia; Tortolero-Luna, Guillermo; Williams, Janet; Morales-Campos, Daisy Y.
2011-01-01
While self-efficacy (SE), a construct from Social Cognitive Theory, has been shown to influence other screening behaviors, few measures currently exist for measuring Pap test SE. This paper describes the development and psychometric testing of such a measure for Mexican-American women. Data from two separate samples of Mexican-American women 50 years or older, obtained as part of a study to develop and evaluate a breast and cervical cancer screening educational program, were used in the current study. Exploratory factor analysis indicated a single factor solution and all item loadings were > .73. Confirmatory analysis confirmed a single factor structure with all standardized loadings greater than .40 as hypothesized. The eight item SE scale demonstrated high internal consistency (Cronbach's alpha = .95). As hypothesized, SE was correlated with knowledge, prior experience, and screening intention. Logistic regression supported the theoretical relationship that women with higher SE were more likely to have had a recent Pap test. Findings showed a significant increase in SE following the intervention, indicating the measure has good sensitivity to change over time. PMID:19258484
Computer-Mediated Assessment of Intelligibility in Aphasia and Apraxia of Speech
Haley, Katarina L.; Roth, Heidi; Grindstaff, Enetta; Jacks, Adam
2011-01-01
Background Previous work indicates that single word intelligibility tests developed for dysarthria are sensitive to segmental production errors in aphasic individuals with and without apraxia of speech. However, potential listener learning effects and difficulties adapting elicitation procedures to coexisting language impairments limit their applicability to left hemisphere stroke survivors. Aims The main purpose of this study was to examine basic psychometric properties for a new monosyllabic intelligibility test developed for individuals with aphasia and/or AOS. A related purpose was to examine clinical feasibility and potential to standardize a computer-mediated administration approach. Methods & Procedures A 600-item monosyllabic single word intelligibility test was constructed by assembling sets of phonetically similar words. Custom software was used to select 50 target words from this test in a pseudo-random fashion and to elicit and record production of these words by 23 speakers with aphasia and 20 neurologically healthy participants. To evaluate test-retest reliability, two identical sets of 50-word lists were elicited by requesting repetition after a live speaker model. To examine the effect of a different word set and auditory model, an additional set of 50 different words was elicited with a pre-recorded model. The recorded words were presented to normal-hearing listeners for identification via orthographic and multiple-choice response formats. To examine construct validity, production accuracy for each speaker was estimated via phonetic transcription and rating of overall articulation. Outcomes & Results Recording and listening tasks were completed in less than six minutes for all speakers and listeners. Aphasic speakers were significantly less intelligible than neurologically healthy speakers and displayed a wide range of intelligibility scores. Test-retest and inter-listener reliability estimates were strong. No significant difference was found in scores based on recordings from a live model versus a pre-recorded model, but some individual speakers favored the live model. Intelligibility test scores correlated highly with segmental accuracy derived from broad phonetic transcription of the same speech sample and a motor speech evaluation. Scores correlated moderately with rated articulation difficulty. Conclusions We describe a computerized, single-word intelligibility test that yields clinically feasible, reliable, and valid measures of segmental speech production in adults with aphasia. This tool can be used in clinical research to facilitate appropriate participant selection and to establish matching across comparison groups. For a majority of speakers, elicitation procedures can be standardized by using a pre-recorded auditory model for repetition. This assessment tool has potential utility for both clinical assessment and outcomes research. PMID:22215933
Khazov, M V; Romanov, S V; Abaeva, O P; Murigina, M M
2015-01-01
The article considers results of study concerning prevalence of physicians working over standards of single job position in multifield hospital, including factors motivating to extra job. The research purpose was to analyze impact of gender age structure of medical personnel of multfield public medical organization on motivation of physicians to work over standards of single job position. The objectives consisted of analyzing prevalence of over standard work of medical personnel of multifield public medical organization with consideration of social structure and studying factors motivating physicians to work over standards of single job position. The study was carried out on the basis of questionnaire survey of physicians. The results of study testify higher degree of prevalence of working over standards of single job position in modern health care. So, 64.8 ± 3.6% of respondents work subject to conditions of internal and/or external moonlighting. Moreover; one third of physicians enlisted to extra job. Among physicians males more often than females work subject to conditions of moonlighting, perform extra job, enlist to working during days off. The specialists of age group from 35 to 54 years work subject to conditions of external and internal moonlighting more often than younger physicians. Among physicians, the most significant cause of working subject to conditions of moonlighting is additional earnings. At that, every fifth physician works over standards of job position with purpose to increase one's professional competence. The study results permit concluding that aspects of social structure of modern medical staff significantly impact motivation and hence possibility of enlisting workers to work over standards of single job position.
True versus Apparent Malaria Infection Prevalence: The Contribution of a Bayesian Approach
Claes, Filip; Van Hong, Nguyen; Torres, Kathy; Mao, Sokny; Van den Eede, Peter; Thi Thinh, Ta; Gamboa, Dioni; Sochantha, Tho; Thang, Ngo Duc; Coosemans, Marc; Büscher, Philippe; D'Alessandro, Umberto; Berkvens, Dirk; Erhart, Annette
2011-01-01
Aims To present a new approach for estimating the “true prevalence” of malaria and apply it to datasets from Peru, Vietnam, and Cambodia. Methods Bayesian models were developed for estimating both the malaria prevalence using different diagnostic tests (microscopy, PCR & ELISA), without the need of a gold standard, and the tests' characteristics. Several sources of information, i.e. data, expert opinions and other sources of knowledge can be integrated into the model. This approach resulting in an optimal and harmonized estimate of malaria infection prevalence, with no conflict between the different sources of information, was tested on data from Peru, Vietnam and Cambodia. Results Malaria sero-prevalence was relatively low in all sites, with ELISA showing the highest estimates. The sensitivity of microscopy and ELISA were statistically lower in Vietnam than in the other sites. Similarly, the specificities of microscopy, ELISA and PCR were significantly lower in Vietnam than in the other sites. In Vietnam and Peru, microscopy was closer to the “true” estimate than the other 2 tests while as expected ELISA, with its lower specificity, usually overestimated the prevalence. Conclusions Bayesian methods are useful for analyzing prevalence results when no gold standard diagnostic test is available. Though some results are expected, e.g. PCR more sensitive than microscopy, a standardized and context-independent quantification of the diagnostic tests' characteristics (sensitivity and specificity) and the underlying malaria prevalence may be useful for comparing different sites. Indeed, the use of a single diagnostic technique could strongly bias the prevalence estimation. This limitation can be circumvented by using a Bayesian framework taking into account the imperfect characteristics of the currently available diagnostic tests. As discussed in the paper, this approach may further support global malaria burden estimation initiatives. PMID:21364745
Southern, Danielle A; Roberts, Barbara; Edwards, Alun; Dean, Stafford; Norton, Peter; Svenson, Lawrence W; Larsen, Erik; Sargious, Peter; Lau, David C W; Ghali, William A
2010-01-01
This study assessed the validity of a widely-accepted administrative data surveillance methodology for identifying individuals with diabetes relative to three laboratory data reference standard definitions for diabetes. We used a combination of linked regional data (hospital discharge abstracts and physician data) and laboratory data to test the validity of administrative data surveillance definitions for diabetes relative to a laboratory data reference standard. The administrative discharge data methodology includes two definitions for diabetes: a strict administrative data definition of one hospitalization code or two physician claims indicating diabetes; and a more liberal definition of one hospitalization code or a single physician claim. The laboratory data, meanwhile, produced three reference standard definitions based on glucose levels +/- HbA1c levels. Sensitivities ranged from 68.4% to 86.9% for the administrative data definitions tested relative to the three laboratory data reference standards. Sensitivities were higher for the more liberal administrative data definition. Positive predictive values (PPV), meanwhile, ranged from 53.0% to 88.3%, with the liberal administrative data definition producing lower PPVs. These findings demonstrate the trade-offs of sensitivity and PPV for selecting diabetes surveillance definitions. Centralized laboratory data may be of value to future surveillance initiatives that use combined data sources to optimize case detection.
Acceleration of Linear Finite-Difference Poisson-Boltzmann Methods on Graphics Processing Units.
Qi, Ruxi; Botello-Smith, Wesley M; Luo, Ray
2017-07-11
Electrostatic interactions play crucial roles in biophysical processes such as protein folding and molecular recognition. Poisson-Boltzmann equation (PBE)-based models have emerged as widely used in modeling these important processes. Though great efforts have been put into developing efficient PBE numerical models, challenges still remain due to the high dimensionality of typical biomolecular systems. In this study, we implemented and analyzed commonly used linear PBE solvers for the ever-improving graphics processing units (GPU) for biomolecular simulations, including both standard and preconditioned conjugate gradient (CG) solvers with several alternative preconditioners. Our implementation utilizes the standard Nvidia CUDA libraries cuSPARSE, cuBLAS, and CUSP. Extensive tests show that good numerical accuracy can be achieved given that the single precision is often used for numerical applications on GPU platforms. The optimal GPU performance was observed with the Jacobi-preconditioned CG solver, with a significant speedup over standard CG solver on CPU in our diversified test cases. Our analysis further shows that different matrix storage formats also considerably affect the efficiency of different linear PBE solvers on GPU, with the diagonal format best suited for our standard finite-difference linear systems. Further efficiency may be possible with matrix-free operations and integrated grid stencil setup specifically tailored for the banded matrices in PBE-specific linear systems.
Hatton, Anna L; Hug, François; Chen, Sarah H; Reid, Christine; Sorensen, Nicole A; Tucker, Kylie
2016-10-01
Middle-aged adults with painful hip conditions show balance impairments that are consistent with an increased risk of falls. Pathological changes at the hip, accompanied by pain, may accelerate pre-existing age-related balance deficits present in midlife. To consider the influence of pain alone, we investigated the effects of acute experimental hip muscle pain on dynamic single-limb balance in middle-aged adults. Thirty-four healthy adults aged 40-60 years formed two groups (Group-1: n=16; Group-2: n=18). Participants performed four tasks: Reactive Sideways Stepping (ReactSide); Star Excursion Balance Test (SEBT); Step Test; Single-Limb Squat; before and after an injection of hypertonic saline into the right gluteus medius muscle (Group-1) or ∼5min rest (Group-2). Balance measures included the range and standard deviation of centre of pressure (CoP) movement in mediolateral and anterior-posterior directions, and CoP total path velocity (ReactSide, Squat); reach distance (SEBT); and number of completed steps (Step Test). Data were assessed using three-way analysis of variance. Motor outcomes were altered during the second repetition of tasks irrespective of exposure to experimental hip muscle pain or rest, with reduced SEBT anterior reach (-1.2±4.1cm, P=0.027); greater step number during Step Test (1.5±1.7 steps, P<0.001); and slower CoP velocity during Single-Limb Squat (-4.9±9.4mms -1 , P=0.024). Factors other than the presence of pain may play a greater role in balance impairments in middle-aged adults with hip pathologies. Copyright © 2016 Elsevier B.V. All rights reserved.
Rumpler, M; Mader, J K; Fischer, J P; Thar, R; Granger, J M; Deliane, F; Klimant, I; Aberer, F; Sinner, F; Pieber, T R; Hajnsek, M
2017-02-15
The combination of continuous glucose monitoring (CGM) and continuous subcutaneous insulin infusion can be used to improve the treatment of patients with diabetes. The aim of this study was to advance an existing preclinical single-port system for clinical application by integrating the sensors of a phosphorescence based CGM system into a standard insulin infusion set. The extracorporeal optical phase fluorimeter was miniaturised and is now comparable with commercial CGM systems regarding size, weight and wear comfort. Sensor chemistry was adapted to improve the adhesion of the sensor elements on the insulin infusion set. In-vitro tests showed a linear correlation of R 2 =0.998 between sensor values and reference glucose values in the range of 0-300mg/dl. Electrical and cytotoxicity tests showed no negative impact on human health. Two single-port devices were tested in each of 12 patients with type 1 diabetes mellitus in a clinical set-up for 12h. Without additional data processing, the overall median absolute relative difference (median ARD) was 22.5%. For some of the used devices the median ARD was even well below 10%. The present results show that individual glucose sensors performance of the single-port system is comparable with commercial CGM systems but further improvements are needed. The new system offers a high extent of safety and usability by combining insulin infusion and continuous glucose measurement in a single-port system which could become a central element in an artificial pancreas for an improved treatment of patients with type 1 diabetes mellitus. Copyright © 2016 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nelson, Austin; Martin, Gregory; Hurtt, James
As revised interconnection standards for grid-tied photovoltaic (PV) inverters address new advanced grid support functions (GSFs), there is increasing interest in inverter performance in the case of abnormal grid conditions. The growth of GSF-enabled inverters has outpaced the industry standards that define their operation, although recently published updates to UL1741 with Supplement SA define test conditions for GSFs such as volt-var control, frequency-watt control, and volt-age/frequency ride-through, among others. A comparative experimental evaluation has been completed on four commercially available, three-phase PV inverters in the 24.0-39.8 kVA power range on their GSF capability and the effect on abnormal grid conditionmore » response. This study examines the impact particular GSF implementations have on run-on times during islanding conditions, peak voltages in load rejection overvoltage scenarios, and peak currents during single-phase and three-phase fault events for individual inverters. This report reviews comparative test data, which shows that GSFs have little impact on the metrics of interest in most tests cases.« less
Experimental Evaluation of Grid Support Enabled PV Inverter Response to Abnormal Grid Conditions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nelson, Austin A; Martin, Gregory D; Hurtt, James
As revised interconnection standards for grid-tied photovoltaic (PV) inverters address new advanced grid support functions (GSFs), there is increasing interest in inverter performance in the case of abnormal grid conditions. The growth of GSF-enabled inverters has outpaced the industry standards that define their operation, although recently published updates to UL1741 Supplement SA define test conditions for GSFs such as volt-var control, frequency-watt control, and voltage/frequency ride-through, among others. This paper describes the results of a comparative experimental evaluation on four commercially available, three-phase PV inverters in the 24.0-39.8 kVA power range on their GSF capability and its effect on abnormalmore » grid condition response. The evaluation examined the impact particular GSF implementations have on run-on times during islanding conditions, peak voltages in load rejection overvoltage scenarios, and peak currents during single-phase and three-phase fault events for individual inverters. Testing results indicated a wide variance in the performance of GSF enabled inverters to various test cases.« less
Analysis of Data in Accordance with Space Flight Mission Environmental Requirements
NASA Technical Reports Server (NTRS)
Shei, Monica
2011-01-01
The Environmental Assurance Program sets forth standards to ensure that all flight hardware is compatible with the environments that will be encountered during a spacecraft mission. It outlines the design, test and analysis, and risk control standards for the mission and certifies that it will survive in any external or self-induced environments that the spacecraft may experience. The Environmental Requirements Document (ERD) is the most important document in the Environmental Assurance Program, providing the design and test requirements for the project's flight system, subsystems, assemblies, and instruments. This summer's project was to assist Environmental Requirements Engineers (ERE's) in completing the Environmental Assurance Program Summary Report for both the Juno Project and Mars Science Laboratory (MSL) Project. The Summary Report is a document summarizing the environmental tests and analyses of each spacecraft at both the assembly and system level. It compiles a source of all relevant information such as waivers and Problem/Failure Reports (PFRs) into a single report for easy reference of how well the spacecraft met the requirements of the project.
Test and analysis of Celion 3000/PMR-15, graphite/polyimide bonded composite joints: Data report
NASA Technical Reports Server (NTRS)
Cushman, J. B.; Mccleskey, S. F.; Ward, S. H.
1982-01-01
Standard single lap, double lap and symmetric step lap bonded joints of Celion 3000/PMR-15 graphite/polyimide composite were evaluated. Composite to composite and composite to titanium joints were tested at 116 K (-250 F), 294 K (70 F) and 561 K (550 F). Joint parameters evaluated are lap length, adherend thickness, adherend axial stiffness, lamina stacking sequence and adherend tapering. Advanced joint concepts were examined to establish the change in performance of preformed adherends, scalloped adherends and hybrid systems. The material properties of the high temperature adhesive, designated A7F, used for bonding were established. The bonded joint tests resulted in interlaminar shear or peel failures of the composite and there were very few adhesive failures. Average test results agree with expected performance trends for the various test parameters. Results of finite element analyses and of test/analysis correlations are also presented.
Hutt, Charles R.; Nigbor, Robert L.; Evans, John R.
2009-01-01
Testing and specification of seismic and earthquake-engineering sensors and recorders has been marked by significant variations in procedures and selected parameters. These variations cause difficulty in comparing such specifications and test results. In July 1989, and again in May 2005, the U.S. Geological Survey hosted international public/private workshops with the goal of defining widely accepted guidelines for the testing of seismological inertial sensors, seismometers, and accelerometers. This document reports the Proceedings of the 2005 workshop and includes as Appendix 6 the report of the 1989 workshop. In a future document, we will attempt to collate and rationalize a single set of formal guidelines for testing and specifying seismic sensors, supplementing Advanced National Seismic System (ANSS) guidelines on instrumentation likely used by ANSS as its standard for verification, acceptance, and intermittent testing, as well as for responses to ANSS instrument requisitions.
Varona, Omar de; Steinke, Michael; Neumann, Jörg; Kracht, Dietmar
2018-06-01
Emerging applications, such as gravitational wave astronomy, demand single-frequency lasers with diffraction-limited emission at 1.5 μm. Fiber amplifiers have greatly evolved to fulfill these requirements. Hundreds of watts are feasible using large-mode-area and specialty fibers. However, their application in a few watts to tens of watts in monolithic systems is unnecessarily complex due to the poor commercial availability of fiber components and standard integration procedures. In this Letter we propose and experimentally demonstrate a novel and simple method to amplify single-frequency signals at 1.5 μm up to tens of watts by core-pumping single-mode Er 3+ :Yb 3+ fiber amplifiers at 1018 nm. The proof-of-principle system is tested with different active fibers, lengths, and seed power levels. Over 11 W with an efficiency of more than 48% versus launched power is achieved. Additionally, performance degradation during operation was observed for which photodarkening due to P1 defects might be an explanation.
Detailed analysis of complex single molecule FRET data with the software MASH
NASA Astrophysics Data System (ADS)
Hadzic, Mélodie C. A. S.; Kowerko, Danny; Börner, Richard; Zelger-Paulus, Susann; Sigel, Roland K. O.
2016-04-01
The processing and analysis of surface-immobilized single molecule FRET (Förster resonance energy transfer) data follows systematic steps (e.g. single molecule localization, clearance of different sources of noise, selection of the conformational and kinetic model, etc.) that require a solid knowledge in optics, photophysics, signal processing and statistics. The present proceeding aims at standardizing and facilitating procedures for single molecule detection by guiding the reader through an optimization protocol for a particular experimental data set. Relevant features were determined from single molecule movies (SMM) imaging Cy3- and Cy5-labeled Sc.ai5γ group II intron molecules synthetically recreated, to test the performances of four different detection algorithms. Up to 120 different parameterizations per method were routinely evaluated to finally establish an optimum detection procedure. The present protocol is adaptable to any movie displaying surface-immobilized molecules, and can be easily reproduced with our home-written software MASH (multifunctional analysis software for heterogeneous data) and script routines (both available in the download section of www.chem.uzh.ch/rna).
Attari, Seyed Ghavameddin; Bahrami, Abdolrahman; Shahna, Farshid Ghorbani; Heidari, Mahmoud
2014-01-01
A green, environmental friendly and sensitive method for determination of volatile organohalogen compounds was described in this paper. The method is based on a homemade sol-gel single-walled carbon nanotube/silica composite coated solid-phase microextraction to develop for sampling and analysis of Carbon tetrachloride, Benzotrichloride, Chloromethyl methyl ether and Trichloroethylene in air. Application of this method was investigated under different laboratory conditions. Predetermined concentrations of each analytes were prepared in a home-made standard chamber and the influences of experimental parameters such as temperature, humidity, extraction time, storage time, desorption temperature, desorption time and the sorbent performance were investigated. Under optimal conditions, the use of single-walled carbon nanotube/silica composite fiber showed good performance, high sensitive and fast sampling of volatile organohalogen compounds from air. For linearity test the regression correlation coefficient was more than 98% for analyte of interest and linear dynamic range for the proposed fiber and the applied Gas Chromatography-Flame Ionization Detector technique was from 1 to 100 ngmL(-1). Method detection limits ranged between 0.09 to 0.2 ngmL(-1) and method quantification limits were between 0.25 and 0.7 ngmL(-1). Single-walled carbon nanotube/silica composite fiber was highly reproducible, relative standard deviations were between 4.3 to 11.7 percent.
Sims, Tamara; Holmes, Tyson H.; Bravata, Dena M.; Garber, Alan M.; Nelson, Lorene M.; Goldstein, Mary K.
2008-01-01
Objective To use unweighted counts of dependencies in Activities of Daily Living (ADLs) to assess the impact of functional impairment requires an assumption of equal preferences for each ADL dependency. To test this assumption, we analyzed standard gamble utilities of single and combination ADL dependencies among older adults. Study Design and Setting: Four hundred older adults used multimedia software (FLAIR1) to report standard gamble utilities for their current health and hypothetical health states of dependency in each of 7 ADLs and 8 of 30 combinations of ADL dependencies. Results Utilities for health states of multiple ADL dependencies were often greater than for states of single ADL dependencies. Dependence in eating, the ADL dependency with the lowest utility rating of the single ADL dependencies, ranked lower than 7 combination states. Similarly, some combination states with fewer ADL dependencies had lower utilities than those with more ADL dependencies. These findings were consistent across groups by gender, age, and education. Conclusion Our results suggest that the count of ADL dependencies does not adequately represent the utility for a health state. Cost-effectiveness analyses and other evaluations of programs that prevent or treat functional dependency should apply utility-weights rather than relying on simple ADL counts. PMID:18722749
Haegerbaeumer, Arne; Höss, Sebastian; Ristau, Kai; Claus, Evelyn; Möhlenkamp, Christel; Heininger, Peter; Traunspurger, Walter
2016-12-01
Soft sediments are often hotspots of chemical contamination, and a thorough ecotoxicological assessment of this habitat can help to identify the causes of stress and to improve the health of the respective ecosystems. As an important component of the ecologically relevant meiobenthic fauna, nematodes can be used for sediment assessments, with various assay tools ranging from single-species toxicity tests to field studies. In the present study, microcosms containing sediment were used to investigate direct and indirect effects of zinc on natural nematode assemblages, and acute community toxicity tests considering only direct toxicity were conducted. The responses of the various freshwater nematode species in both approaches were compared with those of Caenorhabditis elegans, determined in standardized tests (ISO 10872). At a median lethal concentration (LC50) of 20 mg Zn/L, C. elegans represented the median susceptibility of 15 examined nematode species examined in the acute community toxicity tests. In the microcosms, Zn affected the nematodes dose-dependently, with changes in species composition first detected at 13 mg Zn/kg to 19 mg Zn/kg sediment dry weight. The observed species sensitivities in the microcosms corresponded better to field observations than to the results of the acute community toxicity tests. Environ Toxicol Chem 2016;35:2987-2997. © 2016 SETAC. © 2016 SETAC.
An Examination of Strategy Implementation During Abstract Nonlinguistic Category Learning in Aphasia
Kiran, Swathi
2015-01-01
Purpose Our purpose was to study strategy use during nonlinguistic category learning in aphasia. Method Twelve control participants without aphasia and 53 participants with aphasia (PWA) completed a computerized feedback-based category learning task consisting of training and testing phases. Accuracy rates of categorization in testing phases were calculated. To evaluate strategy use, strategy analyses were conducted over training and testing phases. Participant data were compared with model data that simulated complex multi-cue, single feature, and random pattern strategies. Learning success and strategy use were evaluated within the context of standardized cognitive–linguistic assessments. Results Categorization accuracy was higher among control participants than among PWA. The majority of control participants implemented suboptimal or optimal multi-cue and single-feature strategies by testing phases of the experiment. In contrast, a large subgroup of PWA implemented random patterns, or no strategy, during both training and testing phases of the experiment. Conclusions Person-to-person variability arises not only in category learning ability but also in the strategies implemented to complete category learning tasks. PWA less frequently developed effective strategies during category learning tasks than control participants. Certain PWA may have impairments of strategy development or feedback processing not captured by language and currently probed cognitive abilities. PMID:25908438
Naucke, T J; Kröpke, R; Benner, G; Schulz, J; Wittern, K P; Rose, A; Kröckel, U; Grünewald, H W
2007-06-01
Seven proprietary repellent formulations (3 hydro-alcoholic spray solutions and 4 skin lotions) with active ingredient IR3,535 (ethyl butylacetylaminopropionate, EBAAP) or Picaridin (hydroxyethyl isobutyl piperidine carboxylate, KBR 3,023, Bayrepel) were tested in a field study on 10 test persons over a period of 10 h for their efficacy at preventing bites. The tests were conducted in Belo Horizonte, Brazil on field populations of the yellow fever mosquito Aedes aegypti. The concentration of the active substances ranged from 10% to 20%. All the tested samples provided lasting protection (time to first bite) over several hours: ranging from 5 h 20 min to 6 h 50 min with a mean of approximately 6 h. The longest protection until the second bite (=first confirmation bite) was approximately 7 h 40 min, whereas the shortest protection was 6 h 50 min. The longest protection until the third bite (=second confirmation bite) was 8 h 35 min, whereas the shortest protection was 7 h 40 min. In the control tests in which none of the samples were applied, the mean times until the first, second and third bites were 26, 46 and 59 min, respectively. The basis for this field study was provided by two American guidelines, which have the greatest international acceptance. The first is a draft guideline from the Environmental Protection Agency (EPA (United States Environmental Protection Agency), Product performance test guidelines. OPPTS 810.3700. Insect repellents for human skin and outdoor premises. Public Draft, 1999) and the second is a standard from the American Society for Testing and Materials (ASTM (American Society for Testing and Materials International), E 939-94 (reapproved 2,000): standard test method of field testing topical applications of compounds as repellents for medically important and pest arthropods (including insects, ticks, and mites): I. Mosquitoes, 2,000). Both guidelines recommend measuring the duration of protection until the first and second bites and also determining the relative protection efficacy in terms of a 95% protection level. The ASTM standard permits different repellents to be applied, whereas the EPA guidelines only permit the use of a single repellent (in different concentrations) on the extremities (forearms or lower leg). In the study presented here, to exclude any possibility of different repellents or concentrations of a single repellent having a reciprocal effect on each other, each test person had repellent samples applied to only one of their forearms. The other forearm was used as a control for making comparative checks every hour and for determining the biting pressure. There was no significant difference in protection times between the two active substances.
Glove perforation rate in vascular surgery--a comparison between single and double gloving.
Aarnio, P; Laine, T
2001-05-01
In surgery intact gloves act as a sterile barrier between surgeon and patient. The impermeable gloves protect the surgeon from bloodborne pathogens such as HIV, hepatitis B, and hepatitis C. On the other hand, the surgical wound is protected from micro-organisms from the skin of the surgeon. One objective of this study was to compare puncture rates between the double gloving color indication system and single-use gloves and the other to determine the extent to which glove perforations remain undetected during the course of vascular surgical operations. The study material comprised all gloves used in vascular surgical operations at Satakunta Central Hospital for a period of two months. The analysis was made by the glove type in a prospective and randomised manner. Gloves were tested immediately after the surgical procedure using the approved standardized water-leak method. With this method the glove is filled with water using a special filling tube, and the water-filled glove is then checked for two minutes to detect any holes. The gloves used in this study were either double gloves with indicator, or the standard glove used at our hospital. In 73 operations altogether 200 gloves were tested, half of them were double gloves and half were single gloves. The perforation occurred in the double gloves 3 times and with single gloves 12 times. The overall perforation rate was 15 out of 200 gloves (7.5%). The detection of perforation during surgery was 60%. Most frequently the perforation was located in the second finger of the left hand, 9 out of 15 perforations. In view of the critical importance of safety at work both transmitting the pathogens from the skin of the surgeon to the wound and transmitting the bloodborne pathogens from the patient to the surgeon, it is very important to use double gloving at least in operations where there is a high risk of glove perforation.
Carp, Sarah B.; Rothwell, Emily S.; Bourdon, Alexis; Freeman, Sara M.; Ferrer, Emilio; Bales, Karen L.
2017-01-01
Partner preference, or the selective social preference for a pair mate, is a key behavioral indicator of social monogamy. Standardized partner preference testing has been used extensively in rodents but a single test has not been standardized for primates. The goal of this study was to develop a partner preference test with socially monogamous titi monkeys (Callicebus cupreus) adapted from the widely used rodent test. In Experiment 1, we evaluated the test with pairs of titi monkeys (N=12) in a three-chambered apparatus for three hours. The subject was placed in the middle chamber, with grated windows separating it from its partner on one side and an opposite sex stranger on the other side. Subjects spent a greater proportion of time in proximity to their partners’ windows than the strangers’, indicating a consistent preference for the partner over the stranger. Touching either window did not differ between partners and strangers, suggesting it is not a reliable measure of preference. Subjects chose their partner more than the stranger during catch and release sessions at the end of the test. In Experiment 2, we compared responses of females with current partners (N=12) in the preference test with other relationship types representing former attachment bonds (N=13) and no attachment bond (N=8). Only females from established pair bonds spent significantly more time near their partner’s window compared to the stranger indicating that this measure of preference is unique to current partners. Other measures of preference did not differentiate behavior toward a current partner and other relationship types. This test reproduces behavioral patterns found in previous studies in titi monkeys highlighting the accuracy of this new partner preference test. This test can be used as a standardized measure of partner preference in titi monkeys to quantitatively study pair bonding and evaluate factors influencing partner preference. PMID:26235811
A Standardized Mean Difference Effect Size for Single Case Designs
ERIC Educational Resources Information Center
Hedges, Larry V.; Pustejovsky, James E.; Shadish, William R.
2012-01-01
Single case designs are a set of research methods for evaluating treatment effects by assigning different treatments to the same individual and measuring outcomes over time and are used across fields such as behavior analysis, clinical psychology, special education, and medicine. Emerging standards for single case designs have focused attention on…
Chen, Xiang-Wu; Zhao, Ying-Xi
2017-01-01
AIM To compare the diagnostic performance of isolated-check visual evoked potential (icVEP) and standard automated perimetry (SAP), for evaluating the application values of icVEP in the detection of early glaucoma. METHODS Totally 144 subjects (288 eyes) were enrolled in this study. icVEP testing was performed with the Neucodia visual electrophysiological diagnostic system. A 15% positive-contrast (bright) condition pattern was used in this device to differentiate between glaucoma patients and healthy control subjects. Signal-to-noise ratios (SNR) were derived based on a multivariate statistic. The eyes were judged as abnormal if the test yielded an SNR≤1. SAP testing was performed with the Humphrey Field Analyzer II. The visual fields were deemed as abnormality if the glaucoma hemifield test results outside normal limits; or the pattern standard deviation with P<0.05; or the cluster of three or more non-edge points on the pattern deviation plot in a single hemifield with P<0.05, one of which must have a P<0.01. Disc photographs were graded as either glaucomatous optic neuropathy or normal by two experts who were masked to all other patient information. Moorfields regression analysis (MRA) used as a separate diagnostic classification was performed by Heidelberg retina tomograph (HRT). RESULTS When the disc photograph grader was used as diagnostic standard, the sensitivity for SAP and icVEP was 32.3% and 38.5% respectively and specificity was 82.3% and 77.8% respectively. When the MRA Classifier was used as the diagnostic standard, the sensitivity for SAP and icVEP was 48.6% and 51.4% respectively and specificity was 84.1% and 78.0% respectively. When the combined structural assessment was used as the diagnostic standard, the sensitivity for SAP and icVEP was 59.2% and 53.1% respectively and specificity was 84.2% and 84.6% respectivlely. There was no statistical significance between the sensitivity or specificity of SAP and icVEP, regardless of which diagnostic standard was based on. CONCLUSION The diagnostic performance of icVEP is not better than that of SAP in the detection of early glaucoma. PMID:28503434
NASA Astrophysics Data System (ADS)
Yarnykh, V.; Korostyshevskaya, A.
2017-08-01
Macromolecular proton fraction (MPF) is a biophysical parameter describing the amount of macromolecular protons involved into magnetization exchange with water protons in tissues. MPF represents a significant interest as a magnetic resonance imaging (MRI) biomarker of myelin for clinical applications. A recent fast MPF mapping method enabled clinical translation of MPF measurements due to time-efficient acquisition based on the single-point constrained fit algorithm. However, previous MPF mapping applications utilized only 3 Tesla MRI scanners and modified pulse sequences, which are not commonly available. This study aimed to test the feasibility of MPF mapping implementation on a 1.5 Tesla clinical scanner using standard manufacturer’s sequences and compare the performance of this method between 1.5 and 3 Tesla scanners. MPF mapping was implemented on 1.5 and 3 Tesla MRI units of one manufacturer with either optimized custom-written or standard product pulse sequences. Whole-brain three-dimensional MPF maps obtained from a single volunteer were compared between field strengths and implementation options. MPF maps demonstrated similar quality at both field strengths. MPF values in segmented brain tissues and specific anatomic regions appeared in close agreement. This experiment demonstrates the feasibility of fast MPF mapping using standard sequences on 1.5 T and 3 T clinical scanners.
Vidovic, Luka; Majaron, Boris
2014-02-01
Diffuse reflectance spectra (DRS) of biological samples are commonly measured using an integrating sphere (IS). To account for the incident light spectrum, measurement begins by placing a highly reflective white standard against the IS sample opening and collecting the reflected light. After replacing the white standard with the test sample of interest, DRS of the latter is determined as the ratio of the two values at each involved wavelength. However, such a substitution may alter the fluence rate inside the IS. This leads to distortion of measured DRS, which is known as single-beam substitution error (SBSE). Barring the use of more complex experimental setups, the literature states that only approximate corrections of the SBSE are possible, e.g., by using look-up tables generated with calibrated low-reflectivity standards. We present a practical method for elimination of SBSE when using IS equipped with an additional reference port. Two additional measurements performed at this port enable a rigorous elimination of SBSE. Our experimental characterization of SBSE is replicated by theoretical derivation. This offers an alternative possibility of computational removal of SBSE based on advance characterization of a specific DRS setup. The influence of SBSE on quantitative analysis of DRS is illustrated in one application example.
Food for Thought … Integrated Testing Strategies for Safety Assessments
Hartung, Thomas; Luechtefeld, Tom; Maertens, Alexandra; Kleensang, Andre
2013-01-01
Summary Despite the fact that toxicology uses many stand-alone tests, a systematic combination of several information sources very often is required: Examples include: when not all possible outcomes of interest (e.g., modes of action), classes of test substances (applicability domains), or severity classes of effect are covered in a single test; when the positive test result is rare (low prevalence leading to excessive false-positive results); when the gold standard test is too costly or uses too many animals, creating a need for prioritization by screening. Similarly, tests are combined when the human predictivity of a single test is not satisfactory or when existing data and evidence from various tests will be integrated. Increasingly, kinetic information also will be integrated to make an in vivo extrapolation from in vitro data. Integrated Testing Strategies (ITS) offer the solution to these problems. ITS have been discussed for more than a decade, and some attempts have been made in test guidance for regulations. Despite their obvious potential for revamping regulatory toxicology, however, we still have little guidance on the composition, validation, and adaptation of ITS for different purposes. Similarly, Weight of Evidence and Evidence-based Toxicology approaches require different pieces of evidence and test data to be weighed and combined. ITS also represent the logical way of combining pathway-based tests, as suggested in Toxicology for the 21st Century. This paper describes the state of the art of ITS and makes suggestions as to the definition, systematic combination, and quality assurance of ITS. PMID:23338803
Improving clinical cognitive testing: report of the AAN Behavioral Neurology Section Workgroup.
Daffner, Kirk R; Gale, Seth A; Barrett, A M; Boeve, Bradley F; Chatterjee, Anjan; Coslett, H Branch; D'Esposito, Mark; Finney, Glen R; Gitelman, Darren R; Hart, John J; Lerner, Alan J; Meador, Kimford J; Pietras, Alison C; Voeller, Kytja S; Kaufer, Daniel I
2015-09-08
To evaluate the evidence basis of single-domain cognitive tests frequently used by behavioral neurologists in an effort to improve the quality of clinical cognitive assessment. Behavioral Neurology Section members of the American Academy of Neurology were surveyed about how they conduct clinical cognitive testing, with a particular focus on the Neurobehavioral Status Exam (NBSE). In contrast to general screening cognitive tests, an NBSE consists of tests of individual cognitive domains (e.g., memory or language) that provide a more comprehensive diagnostic assessment. Workgroups for each of 5 cognitive domains (attention, executive function, memory, language, and spatial cognition) conducted evidence-based reviews of frequently used tests. Reviews focused on suitability for office-based clinical practice, including test administration time, accessibility of normative data, disease populations studied, and availability in the public domain. Demographic and clinical practice data were obtained from 200 respondents who reported using a wide range of cognitive tests. Based on survey data and ancillary information, between 5 and 15 tests in each cognitive domain were reviewed. Within each domain, several tests are highlighted as being well-suited for an NBSE. We identified frequently used single-domain cognitive tests that are suitable for an NBSE to help make informed choices about clinical cognitive assessment. Some frequently used tests have limited normative data or have not been well-studied in common neurologic disorders. Utilizing standardized cognitive tests, particularly those with normative data based on the individual's age and educational level, can enhance the rigor and utility of clinical cognitive assessment. © 2015 American Academy of Neurology.
USDA-ARS?s Scientific Manuscript database
We present two standards developed by the Genomic Standards Consortium (GSC) for reporting bacterial and archaeal genome sequences. Both are extensions of the minimum information about any (x) sequence (MIxS). The standards are the minimum information about a single amplified genome (MISAG) and the ...
Upgraded FAA Airfield Capacity Model. Volume 2. Technical Description of Revisions
1981-02-01
the threshold t k a the time at which departure k is released FIGURE 3-1 TIME AXIS DIAGRAM OF SINGLE RUNWAY OPERATIONS 3-2 J"- SIGMAR the standard...standard deviation of the interarrival time. SIGMAR - the standard deviation of the arrival runway occupancy time. A-5 SINGLE - program subroutine for
Buehler, Tania; Bally, Lia; Dokumaci, Ayse Sila; Stettler, Christoph; Boesch, Chris
2016-06-01
Glycogen is a major substrate in energy metabolism and particularly important to prevent hypoglycemia in pathologies of glucose homeostasis such as type 1 diabetes mellitus (T1DM). (13) C-MRS is increasingly used to determine glycogen in skeletal muscle and liver non-invasively; however, the low signal-to-noise ratio leads to long acquisition times, particularly when glycogen levels are determined before and after interventions. In order to ease the requirements for the subjects and to avoid systematic effects of the lengthy examination, we evaluated if a standardized preparation period would allow us to shift the baseline (pre-intervention) experiments to a preceding day. Based on natural abundance (13) C-MRS on a clinical 3 T MR system the present study investigated the test-retest reliability of glycogen measurements in patients with T1DM and matched controls (n = 10 each group) in quadriceps muscle and liver. Prior to the MR examination, participants followed a standardized diet and avoided strenuous exercise for two days. The average coefficient of variation (CV) of myocellular glycogen levels was 9.7% in patients with T1DM compared with 6.6% in controls after a 2 week period, while hepatic glycogen variability was 13.3% in patients with T1DM and 14.6% in controls. For comparison, a single-session test-retest variability in four healthy volunteers resulted in 9.5% for skeletal muscle and 14.3% for liver. Glycogen levels in muscle and liver were not statistically different between test and retest, except for hepatic glycogen, which decreased in T1DM patients in the retest examination, but without an increase of the group distribution. Since the CVs of glycogen levels determined in a "single session" versus "within weeks" are comparable, we conclude that the major source of uncertainty is the methodological error and that physiological variations can be minimized by a pre-study standardization. For hepatic glycogen examinations, familiarization sessions (MR and potentially strenuous interventions) are recommended. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Full-Scale Crash Tests and Analyses of Three High-Wing Single
NASA Technical Reports Server (NTRS)
Annett, Martin S.; Littell, Justin D.; Stimson, Chad M.; Jackson, Karen E.; Mason, Brian H.
2015-01-01
The NASA Emergency Locator Transmitter Survivability and Reliability (ELTSAR) project was initiated in 2014 to assess the crash performance standards for the next generation of ELT systems. Three Cessna 172 aircraft have been acquired to conduct crash testing at NASA Langley Research Center's Landing and Impact Research Facility. Testing is scheduled for the summer of 2015 and will simulate three crash conditions; a flare to stall while emergency landing, and two controlled flight into terrain scenarios. Instrumentation and video coverage, both onboard and external, will also provide valuable data of airframe response. Full-scale finite element analyses will be performed using two separate commercial explicit solvers. Calibration and validation of the models will be based on the airframe response under these varying crash conditions.
Trujillo, William A.; Sorenson, Wendy R.; La Luzerne, Paul; Austad, John W.; Sullivan, Darryl
2008-01-01
The presence of aristolochic acid in some dietary supplements is a concern to regulators and consumers. A method has been developed, by initially using a reference method as a guide, during single laboratory validation (SLV) for the determination of aristolochic acid I, also known as aristolochic acid A, in botanical species and dietary supplements at concentrations of approximately 2 to 32 μg/g. Higher levels were determined by dilution to fit the standard curve. Through the SLV, the method was optimized for quantification by liquid Chromatography with ultraviolet detection (LC-UV) and LC/mass Spectrometry (MS) confirmation. The test samples were extracted with organic solvent and water, then injected on a reverse phase LC column. Quantification was achieved with linear regression using a laboratory automation system. The SLV study included systematically optimizing the LC-UV method with regard to test sample size, fine grinding of solids, and solvent extraction efficiency. These parameters were varied in increments (and in separate optimization studies), in order to ensure that each parameter was individually studied; the test results include corresponding tables of parameter variations. In addition, the chromatographic conditions were optimized with respect to injection volume and detection wavelength. Precision studies produced overall relative standard deviation values from 2.44 up to 8.26% for aristolochic acid I. Mean recoveries were between 100 and 103% at the 2 μg/g level, between 102 and 103% at the 10 μg/g level, and 104% at the 30 μg/g level. PMID:16915829
Trujillo, William A; Sorenson, Wendy R; La Luzerne, Paul; Austad, John W; Sullivan, Darryl
2006-01-01
The presence of aristolochic acid in some dietary supplements is a concern to regulators and consumers. A method has been developed, by initially using a reference method as a guide, during single laboratory validation (SLV) for the determination of aristolochic acid I, also known as aristolochic acid A, in botanical species and dietary supplements at concentrations of approximately 2 to 32 microg/g. Higher levels were determined by dilution to fit the standard curve. Through the SLV, the method was optimized for quantification by liquid chromatography with ultraviolet detection (LC-UV) and LC/mass spectrometry (MS) confirmation. The test samples were extracted with organic solvent and water, then injected on a reverse phase LC column. Quantification was achieved with linear regression using a laboratory automation system. The SLV study included systematically optimizing the LC-UV method with regard to test sample size, fine grinding of solids, and solvent extraction efficiency. These parameters were varied in increments (and in separate optimization studies), in order to ensure that each parameter was individually studied; the test results include corresponding tables of parameter variations. In addition, the chromatographic conditions were optimized with respect to injection volume and detection wavelength. Precision studies produced overall relative standard deviation values from 2.44 up to 8.26% for aristolochic acid I. Mean recoveries were between 100 and 103% at the 2 microg/g level, between 102 and 103% at the 10 microg/g level, and 104% at the 30 microg/g level.
Healy, Andrew T; Sundar, Swetha J; Cardenas, Raul J; Mageswaran, Prasath; Benzel, Edward C; Mroz, Thomas E; Francis, Todd B
2014-11-01
Single-level anterior cervical discectomy and fusion (ACDF) is an established surgical treatment for cervical myelopathy. Within 10 years of undergoing ACDF, 19.2% of patients develop symptomatic adjacent-level degeneration. Performing ACDF adjacent to prior fusion requires exposure and removal of previously placed hardware, which may increase the risk of adverse outcomes. Zero-profile cervical implants combine an interbody spacer with an anterior plate into a single device that does not extend beyond the intervertebral disc space, potentially obviating the need to remove prior hardware. This study compared the biomechanical stability and adjacent-level range of motion (ROM) following placement of a zero-profile device (ZPD) adjacent to a single-level ACDF against a standard 2-level ACDF. In this in vitro biomechanical cadaveric study, multidirectional flexibility testing was performed by a robotic spine system that simulates flexion-extension, lateral bending, and axial rotation by applying a continuous pure moment load. Testing conditions were as follows: 1) intact, 2) C5-6 ACDF, 3) C4-5 ZPD supraadjacent to simulated fusion at C5-6, and 4) 2-level ACDF (C4-6). The sequence of the latter 2 test conditions was randomized. An unconstrained pure moment of 1.5 Nm with a 40-N simulated head weight load was applied to the intact condition first in all 3 planes of motion and then using the hybrid test protocol, overall intact kinematics were replicated subsequently for each surgical test condition. Intersegmental rotations were measured optoelectronically. Mean segmental ROM for operated levels and adjacent levels was recorded and normalized to the intact condition and expressed as a percent change from intact. A repeated-measures ANOVA was used to analyze the ROM between test conditions with a 95% level of significance. No statistically significant differences in immediate construct stability were found between construct Patterns 3 and 4, in all planes of motion (p > 0.05). At the operated level, C4-5, the zero-profile construct showed greater decreases in axial rotation (-45% vs -36%) and lateral bending (-55% vs -38%), whereas the 2-level ACDF showed greater decreases in flexion-extension (-40% vs -34%). These differences were marginal and not statistically significant. Adjacent-level motion was nearly equivalent, with minor differences in flexion-extension. When treating degeneration adjacent to a single-level ACDF, a zero-profile implant showed stabilizing potential at the operated level statistically similar to that of the standard revision with a 2-level plate. Revision for adjacent-level disease is common, and using a ZPD in this setting should be investigated clinically because it may be a faster, safer alternative.
Mobile Centers For Secondary Power Distribution
NASA Technical Reports Server (NTRS)
Mears, Robert L.
1990-01-01
Concept for distribution of 60-Hz ac power in large building devoted to assembly and testing of equipment improves safety, reduces number of outlets and lengthy cables, and readily accommodates frequent changes in operations and configuration. Power from floor recess fed via unobtrusive cable to portable power management center. A cart containing variety of outlets and circuit breakers, wheeled to convenient location near equipment to be assembled or tested. Power distribution system presents larger range of operational configurations than fixed location. Meets tighter standards to feed computers and delicate instruments. Industrial-grade power suitable for power tools and other hardware. Three-phase and single-phase outlets available from each.
Smith, Erin; Walsh, Lorcan; Doyle, Julie; Greene, Barry; Blake, Catherine
2016-01-01
The timed up and go (TUG) test is a commonly used assessment in older people with variations including the addition of a motor or cognitive dual-task, however in high functioning older adults it is more difficult to assess change. The quantified TUG (QTUG) uses inertial sensors to detect test and gait parameters during the test. If it is to be used in the longitudinal assessment of older adults, it is important that we know which parameters are reliable and under which conditions. This study aims to examine the relative reliability of the QTUG over five consecutive days under single, motor and cognitive dual-task conditions. Twelve community dwelling older adults (10 females, mean age 74.17 (3.88)) performed the QTUG under three conditions for five consecutive days. The relative reliability of each of the gait parameters was assessed using intra-class correlation coefficient (ICC 3,1) and standard error of measurement (SEM). Five of the measures demonstrated excellent reliability (ICC>0.70) under all three conditions (time to complete test, walk time, number of gait cycles, number of steps and return from turn time). Measures of variability and turn derived parameters demonstrated weak reliability under all three conditions (ICC=0.05-0.49). For the most reliable parameters under single-task conditions, the addition of a cognitive task resulted in a reduction in reliability suggesting caution when interpreting results under these conditions. Certain sensor derived parameters during the QTUG test may provide an additional resource in the longitudinal assessment of older people and earlier identification of falls risk. Copyright © 2015 Elsevier B.V. All rights reserved.
Quantitative Improvements in Hop Test Scores After a 6-Week Neuromuscular Training Program
Meierbachtol, Adam; Rohman, Eric; Paur, Eric; Bottoms, John; Tompkins, Marc
2016-01-01
Background: In patients who have undergone anterior cruciate ligament reconstruction (ACLR), the effect of neuromuscular re-education (NMR) programs on standard hop tests outcomes, including limb symmetry indices (LSIs), is unknown. Hypothesis: Both legs will show improvement in hop test–measured units after neuromuscular training, but the involved leg will show relatively greater improvement leading to improved limb symmetry. Patients younger than 18 years will show more improvement than patients who are older. Study Design: Retrospective cohort study. Level of Evidence: Level 3. Methods: Patients self-selected their participation in this NMR program, which was completed after traditional outpatient physical therapy. Pre– and post–hop test scores were recorded as the primary outcome measure. Results: Seventy-one patients met the inclusion criteria and completed hop testing. Overall, the involved leg showed significant improvements (pretest/posttest) for single-leg hop (138.30 cm/156.89 cm), triple crossover hop (370.05 cm/423.11 cm), and timed hop (2.21 s/1.99 s). Similarly, on the uninvolved leg, improvements were seen for the single-leg hop (159.30 cm/171.87 cm) and triple crossover hop (427.50 cm/471.27 cm). Overall mean limb symmetry improved across all 4 hop tests, but there was significant improvement only on the single-leg hop (87% pretest to 92% posttest). Patients younger than 18 years showed mean significant LSI improvement on the triple crossover hop. Conclusion: Utilizing an intensive 6-week NMR program after ACLR prior to return to sport can improve quantitative hop test measurements. Patients younger than 18 years had greater improvement than those 18 years and older. Clinical Relevance: Advanced NMR programs can be successfully utilized in the postoperative ACLR setting to improve quantitative limb symmetry. PMID:27620968
NASA Astrophysics Data System (ADS)
Khanal, Suraj; Leventouri, Theodora; Mahfuz, Hassan; Rondinone, Adam
2014-03-01
Synthetic hydroxyapatite (HAp) bears poor mechanical properties that limit its applicability in orthopedics. We study the possibility of overcoming such limitations by incorporating functionalized single walled carbon nanotubes (fSWCNT) in a biocompatible/bioactive nano-composite. We present results from synthesis and characterization of samples prepared under different processing parameters. Ultra sonication method was to disperse functionalized single walled carbon nanotubes (fSWCNT) in HAp followed by a simple hot assorting method to incorporate with polymerized ɛ-caprolactam. The fracture toughness of the composite materials was tested in compliance with the ASTM D-5045 standard. We have found that while the fracture toughness strongly depends on the processing parameters, a value comparable to the one for cortical bone is achieved. Mechanical properties, electron microscopy and crystal structure properties of the composite materials will be discussed.
Design and analysis of compact MMIC switches utilising GaAs pHEMTs in 3D multilayer technology
NASA Astrophysics Data System (ADS)
Haris, Norshakila; Kyabaggu, Peter B. K.; Alim, Mohammad A.; Rezazadeh, Ali A.
2017-05-01
In this paper, we demonstrate for the first time the implementation of three-dimensional multilayer technology on GaAs-based pseudomorphic high electron mobility transistor (pHEMT) switches. Two types of pHEMT switches are considered, namely single-pole single-throw (SPST) and single-pole double-throw (SPDT). The design and analysis of the devices are demonstrated first through a simulation of the industry-recognised standard model, TriQuint’s Own Model—Level 3, developed by TriQuint Semiconductor, Inc. From the simulation analysis, three optimised SPST and SPDT pHEMT switches which can address applications ranging from L to X bands, are fabricated and tested. The performance of the pHEMT switches using multilayer technology are comparable to those of the current state-of-the-art pHEMT switches, while simultaneously offering compact circuits with the advantages of integration with other MMIC components.
Haerle, Stephan; Sidler, D; Linder, Th; Mueller, W
2008-12-01
The aims were to assess the technical feasibility of using a single electrode in the posterior arytenoid muscles (PAM) for intraoperative monitoring of the recurrent laryngeal nerve (RLN) in thyroid surgery, to validate the new method against the insertion of electrodes placed in the vocal cord muscle, and to report the results of the clinical application of the new concept. A total of 52 patients were enrolled. The handling and safety of RLN monitoring was tested by simultaneous registration of the EMG response from vocal fold electrodes and PAM electrodes. Acoustically and electromyographically we found nearly the same values for the arytenoid muscles as for the vocal folds, although the signals taken from the vocal folds were slightly stronger. PAM recording using a single bipolar electrode is technically feasible and as reliable compared to the standard vocal cord monitoring.
Haltiwanger, Emily Piven; Galindo, David
2013-03-01
The purpose of this study was to determine if occupation-based activities improve diabetes self-management and reduce depressive symptoms in an elderly Mexican-American woman with type 2 diabetes mellitus (T2DM). There have been no known studies showing occupational therapy's role in self-care management of T2DM in people with depressive symptoms. The individual in this single-subject research was evaluated using glycosylated haemoglobin blood tests, four self-reported standardized questionnaires, participant reflective logs and clinical observations following an 8-week intervention. The participant improved on all measures, which were sustained 1 month after treatment ended. Clinical implications highlight a new role for occupational therapists providing early intervention in people with diabetes and depression for secondary prevention of complications of uncontrolled diabetes. Research suggestions include multiple single-subject studies showing occupational therapy contributions. Copyright © 2012 John Wiley & Sons, Ltd.
Triple coupling and parameter resonance in quantum optomechanics with a single atom
NASA Astrophysics Data System (ADS)
Chang, Yue; Ian, H.; Sun, C. P.
2009-11-01
We study the energy level structure and quantum dynamics for a cavity optomechanical system assisted by a single atom. It is found that a triple coupling involving a photon, a phonon and an atom cannot be described only by the quasi-orbital angular momentum at frequency resonance, there also exists the phenomenon of parameter resonance, namely, when the system parameters are matched in some way, the evolution of the end mirror of the cavity is conditioned by the dressed states of the photon-atom subsystem. The quantum decoherence due to this conditional dynamics is studied in detail. In the quasi-classical limit of very large angular momentum, this system will behave like a standard cavity-QED system described by the Jaynes-Cummings (J-C) model when the angular momentum operators are transformed to bosonic operators of a single mode. We test this observation with an experimentally accessible parameter.
A crystallographic model for nickel base single crystal alloys
NASA Technical Reports Server (NTRS)
Dame, L. T.; Stouffer, D. C.
1988-01-01
The purpose of this research is to develop a tool for the mechanical analysis of nickel-base single-crystal superalloys, specifically Rene N4, used in gas turbine engine components. This objective is achieved by developing a rate-dependent anisotropic constitutive model and implementing it in a nonlinear three-dimensional finite-element code. The constitutive model is developed from metallurgical concepts utilizing a crystallographic approach. An extension of Schmid's law is combined with the Bodner-Partom equations to model the inelastic tension/compression asymmetry and orientation-dependence in octahedral slip. Schmid's law is used to approximate the inelastic response of the material in cube slip. The constitutive equations model the tensile behavior, creep response and strain-rate sensitivity of the single-crystal superalloys. Methods for deriving the material constants from standard tests are also discussed. The model is implemented in a finite-element code, and the computed and experimental results are compared for several orientations and loading conditions.
Modeling the effects of low-LET cosmic rays on electronic components.
Keating, A; Goncalves, P; Pimenta, M; Brogueira, P; Zadeh, A; Daly, E
2012-08-01
The effects of cosmic radiation in single cells, organic tissues and electronics are a major concern for space exploration and manned missions. Standard heavy ions radiation tests employ ion cocktails with energy of the order of 10 MeV per nucleon and with a linear energy transfer ranging from a few MeV cm(2) mg(-1) to hundreds of MeV cm(2) mg(-1). In space, cosmic rays show significant fluxes at energies up to the order of GeV per nucleon. The present work aims at investigating single event damage due to low-, high- and very-high-energy ions. The European Space Agency reference single event upset monitor data are used to support the discussion. Finally, the effect of ionization induced directly by primary particles and ionization induced by recoils produced in an electronic device is investigated for different types of devices.
Identification of differentially expressed genes and false discovery rate in microarray studies.
Gusnanto, Arief; Calza, Stefano; Pawitan, Yudi
2007-04-01
To highlight the development in microarray data analysis for the identification of differentially expressed genes, particularly via control of false discovery rate. The emergence of high-throughput technology such as microarrays raises two fundamental statistical issues: multiplicity and sensitivity. We focus on the biological problem of identifying differentially expressed genes. First, multiplicity arises due to testing tens of thousands of hypotheses, rendering the standard P value meaningless. Second, known optimal single-test procedures such as the t-test perform poorly in the context of highly multiple tests. The standard approach of dealing with multiplicity is too conservative in the microarray context. The false discovery rate concept is fast becoming the key statistical assessment tool replacing the P value. We review the false discovery rate approach and argue that it is more sensible for microarray data. We also discuss some methods to take into account additional information from the microarrays to improve the false discovery rate. There is growing consensus on how to analyse microarray data using the false discovery rate framework in place of the classical P value. Further research is needed on the preprocessing of the raw data, such as the normalization step and filtering, and on finding the most sensitive test procedure.
An optical lattice clock with accuracy and stability at the 10(-18) level.
Bloom, B J; Nicholson, T L; Williams, J R; Campbell, S L; Bishof, M; Zhang, X; Zhang, W; Bromley, S L; Ye, J
2014-02-06
Progress in atomic, optical and quantum science has led to rapid improvements in atomic clocks. At the same time, atomic clock research has helped to advance the frontiers of science, affecting both fundamental and applied research. The ability to control quantum states of individual atoms and photons is central to quantum information science and precision measurement, and optical clocks based on single ions have achieved the lowest systematic uncertainty of any frequency standard. Although many-atom lattice clocks have shown advantages in measurement precision over trapped-ion clocks, their accuracy has remained 16 times worse. Here we demonstrate a many-atom system that achieves an accuracy of 6.4 × 10(-18), which is not only better than a single-ion-based clock, but also reduces the required measurement time by two orders of magnitude. By systematically evaluating all known sources of uncertainty, including in situ monitoring of the blackbody radiation environment, we improve the accuracy of optical lattice clocks by a factor of 22. This single clock has simultaneously achieved the best known performance in the key characteristics necessary for consideration as a primary standard-stability and accuracy. More stable and accurate atomic clocks will benefit a wide range of fields, such as the realization and distribution of SI units, the search for time variation of fundamental constants, clock-based geodesy and other precision tests of the fundamental laws of nature. This work also connects to the development of quantum sensors and many-body quantum state engineering (such as spin squeezing) to advance measurement precision beyond the standard quantum limit.
Bingemann, Dieter; Allen, Rachel M.
2012-01-01
We describe a statistical method to analyze dual-channel photon arrival trajectories from single molecule spectroscopy model-free to identify break points in the intensity ratio. Photons are binned with a short bin size to calculate the logarithm of the intensity ratio for each bin. Stochastic photon counting noise leads to a near-normal distribution of this logarithm and the standard student t-test is used to find statistically significant changes in this quantity. In stochastic simulations we determine the significance threshold for the t-test’s p-value at a given level of confidence. We test the method’s sensitivity and accuracy indicating that the analysis reliably locates break points with significant changes in the intensity ratio with little or no error in realistic trajectories with large numbers of small change points, while still identifying a large fraction of the frequent break points with small intensity changes. Based on these results we present an approach to estimate confidence intervals for the identified break point locations and recommend a bin size to choose for the analysis. The method proves powerful and reliable in the analysis of simulated and actual data of single molecule reorientation in a glassy matrix. PMID:22837704
Getter, Nir; Kaplan, Zeev; Todder, Doron
2015-10-01
Electroencephalography source localization neurofeedback, i.e Standardized low-resolution tomography (sLORETA) neurofeedback are non-invasive method for altering region specific brain activity. This is an improvement over traditional neurofeedback which were based on recordings from a single scalp-electrode. We proposed three criteria clusters as a methodological framework to evaluate electroencephalography source localization neurofeedback and present relevant data. Our objective was to evaluate standardized low resolution EEG tomography neurofeedback by examining how training one neuroanatomical area effects the mental rotation task (which is related to the activity of bilateral Parietal regions) and the stop-signal test (which is related to frontal structures). Twelve healthy participants were enrolled in a single session sLORETA neurofeedback protocol. The participants completed both the mental rotation task and the stop-signal test before and after one sLORETA neurofeedback session. During sLORETA neurofeedback sessions participants watched one sitcom episode while the picture quality co-varied with activity in the superior parietal lobule. Participants were rewarded for increasing activity in this region only. Results showed a significant reaction time decrease and an increase in accuracy after sLORETA neurofeedback on the mental rotation task but not after stop signal task. Together with behavioral changes a significant activity increase was found at the left parietal brain after sLORETA neurofeedback compared with baseline. We concluded that activity increase in the parietal region had a specific effect on the mental rotation task. Tasks unrelated to parietal brain activity were unaffected. Therefore, sLORETA neurofeedback could be used as a research, or clinical tool for cognitive disorders. Copyright © 2015 Elsevier B.V. All rights reserved.
Testing Pollen of Single and Stacked Insect-Resistant Bt-Maize on In vitro Reared Honey Bee Larvae
Hendriksma, Harmen P.; Härtel, Stephan; Steffan-Dewenter, Ingolf
2011-01-01
The ecologically and economic important honey bee (Apis mellifera) is a key non-target arthropod species in environmental risk assessment (ERA) of genetically modified (GM) crops. Honey bee larvae are directly exposed to transgenic products by the consumption of GM pollen. But most ERA studies only consider responses of adult bees, although Bt-proteins primarily affect the larval phases of target organisms. We adopted an in vitro larvae rearing system, to assess lethal and sublethal effects of Bt-pollen consumption in a standardized eco-toxicological bioassay. The effects of pollen from two Bt-maize cultivars, one expressing a single and the other a total of three Bt-proteins, on the survival and prepupae weight of honey bee larvae were analyzed. The control treatments included pollen from three non-transgenic maize varieties and of Heliconia rostrata. Three days old larvae were fed the realistic exposure dose of 2 mg pollen within the semi-artificial diet. The larvae were monitored over 120 h, until the prepupal stage, where larvae terminate feeding and growing. Neither single nor stacked Bt-maize pollen showed an adverse effect on larval survival and the prepupal weight. In contrast, feeding of H. rostrata pollen caused significant toxic effects. The results of this study indicate that pollen of the tested Bt-varieties does not harm the development of in vitro reared A. mellifera larvae. To sustain the ecosystem service of pollination, Bt-impact on A. mellifera should always be a crucial part of regulatory biosafety assessments. We suggest that our approach of feeding GM pollen on in vitro reared honey bee larvae is well suited of becoming a standard bioassay in regulatory risk assessments schemes of GM crops. PMID:22194811
Testing pollen of single and stacked insect-resistant Bt-maize on in vitro reared honey bee larvae.
Hendriksma, Harmen P; Härtel, Stephan; Steffan-Dewenter, Ingolf
2011-01-01
The ecologically and economic important honey bee (Apis mellifera) is a key non-target arthropod species in environmental risk assessment (ERA) of genetically modified (GM) crops. Honey bee larvae are directly exposed to transgenic products by the consumption of GM pollen. But most ERA studies only consider responses of adult bees, although Bt-proteins primarily affect the larval phases of target organisms. We adopted an in vitro larvae rearing system, to assess lethal and sublethal effects of Bt-pollen consumption in a standardized eco-toxicological bioassay. The effects of pollen from two Bt-maize cultivars, one expressing a single and the other a total of three Bt-proteins, on the survival and prepupae weight of honey bee larvae were analyzed. The control treatments included pollen from three non-transgenic maize varieties and of Heliconia rostrata. Three days old larvae were fed the realistic exposure dose of 2 mg pollen within the semi-artificial diet. The larvae were monitored over 120 h, until the prepupal stage, where larvae terminate feeding and growing. Neither single nor stacked Bt-maize pollen showed an adverse effect on larval survival and the prepupal weight. In contrast, feeding of H. rostrata pollen caused significant toxic effects. The results of this study indicate that pollen of the tested Bt-varieties does not harm the development of in vitro reared A. mellifera larvae. To sustain the ecosystem service of pollination, Bt-impact on A. mellifera should always be a crucial part of regulatory biosafety assessments. We suggest that our approach of feeding GM pollen on in vitro reared honey bee larvae is well suited of becoming a standard bioassay in regulatory risk assessments schemes of GM crops.
SUV rollover in single vehicle crashes and the influence of ESC and SSF.
Kallan, Michael J; Jermakian, Jessica Steps
2008-10-01
The modern Sport Utility Vehicle (SUV) fleet continues to go through a transformation in response to the concern that they are at an increased risk of rollover. Our research objective was to look at changes in rollover rates for single vehicle crashes in the modern SUV fleet (corresponding to NCAP rollover testing model years) and the impact of electronic stability control (ESC) and lowered center of gravity. We looked at 2001-2006 NASS-GES data on a probability sample of 3,331 SUVs involved in single vehicle crashes, weighted to represent 324,149 crashes in the study population. Static Stability Factor (SSF) information from NCAP testing and ESC presence (from IIHS) were also incorporated. 20.2% of these SUVs were involved a rollover, which decreased by more than half from model year 2001 (25.3%) through 2006 (11.5%). Nearly 9% had ESC as a standard feature, including 47% in model year 2006. The majority of the late model year decline in rollover rates can be attributed to ESC presence and higher SSF. Rollover was two-thirds less likely (adjusted OR=0.33, 95% CI=0.20-0.55) in SUVs with ESC as a standard feature versus those known not to have ESC. Those SUVs with SSF > or = 1.20 were significantly less likely to rollover (adjusted OR=0.31, 95% CI=0.20-0.48). Additional significant predictors of rollover included SUV size, driver age and alcohol use. Our study builds on the previous work of NHTSA, IIHS, and others with regard to rollover risk by looking at an even wider array of late model year SUVs.
SUV Rollover in Single Vehicle Crashes and the Influence of ESC and SSF
Kallan, Michael J.; Jermakian, Jessica Steps
2008-01-01
The modern Sport Utility Vehicle (SUV) fleet continues to go through a transformation in response to the concern that they are at an increased risk of rollover. Our research objective was to look at changes in rollover rates for single vehicle crashes in the modern SUV fleet (corresponding to NCAP rollover testing model years) and the impact of electronic stability control (ESC) and lowered center of gravity. We looked at 2001–2006 NASS-GES data on a probability sample of 3,331 SUVs involved in single vehicle crashes, weighted to represent 324,149 crashes in the study population. Static Stability Factor (SSF) information from NCAP testing and ESC presence (from IIHS) were also incorporated. 20.2% of these SUVs were involved a rollover, which decreased by more than half from model year 2001 (25.3%) through 2006 (11.5%). Nearly 9% had ESC as a standard feature, including 47% in model year 2006. The majority of the late model year decline in rollover rates can be attributed to ESC presence and higher SSF. Rollover was two-thirds less likely (adjusted OR=0.33, 95% CI=0.20–0.55) in SUVs with ESC as a standard feature versus those known not to have ESC. Those SUVs with SSF ≥ 1.20 were significantly less likely to rollover (adjusted OR=0.31, 95% CI=0.20–0.48). Additional significant predictors of rollover included SUV size, driver age and alcohol use. Our study builds on the previous work of NHTSA, IIHS, and others with regard to rollover risk by looking at an even wider array of late model year SUVs. PMID:19026218
Development of a mobbing short scale in the Gutenberg Health Study.
Garthus-Niegel, Susan; Nübling, Matthias; Letzel, Stephan; Hegewald, Janice; Wagner, Mandy; Wild, Philipp S; Blettner, Maria; Zwiener, Isabella; Latza, Ute; Jankowiak, Sylvia; Liebers, Falk; Seidler, Andreas
2016-01-01
Despite its highly detrimental potential, most standard questionnaires assessing psychosocial stress at work do not include mobbing as a risk factor. In the German standard version of COPSOQ, mobbing is assessed with a single item. In the Gutenberg Health Study, this version was used together with a newly developed short scale based on the Leymann Inventory of Psychological Terror. The purpose of the present study was to evaluate the psychometric properties of these two measures, to compare them and to test their differential impact on relevant outcome parameters. This analysis is based on a population-based sample of 1441 employees participating in the Gutenberg Health Study. Exploratory and confirmatory factor analyses and reliability analyses were used to assess the mobbing scale. To determine their predictive validities, multiple linear regression analyses with six outcome parameters and log-binomial regression models for two of the outcome aspects were run. Factor analyses of the five-item scale confirmed a one-factor solution, reliability was α = 0.65. Both the single-item and the five-item scales were associated with all six outcome scales. Effect sizes were similar for both mobbing measures. Mobbing is an important risk factor for health-related outcomes. For the purpose of psychosocial risk assessment in the workplace, both the single-item and the five-item constructs were psychometrically appropriate. Associations with outcomes were about equivalent. However, the single item has the advantage of parsimony, whereas the five-item construct depicts several distinct forms of mobbing.
Borzekowski, Dina L G; Robinson, Thomas N
2005-07-01
Media can influence aspects of a child's physical, social, and cognitive development; however, the associations between a child's household media environment, media use, and academic achievement have yet to be determined. To examine relationships among a child's household media environment, media use, and academic achievement. During a single academic year, data were collected through classroom surveys and telephone interviews from an ethnically diverse sample of third grade students and their parents from 6 northern California public elementary schools. The majority of our analyses derive from spring 2000 data, including academic achievement assessed through the mathematics, reading, and language arts sections of the Stanford Achievement Test. We fit linear regression models to determine the associations between variations in household media and performance on the standardized tests, adjusting for demographic and media use variables. The household media environment is significantly associated with students' performance on the standardized tests. It was found that having a bedroom television set was significantly and negatively associated with students' test scores, while home computer access and use were positively associated with the scores. Regression models significantly predicted up to 24% of the variation in the scores. Absence of a bedroom television combined with access to a home computer was consistently associated with the highest standardized test scores. This study adds to the growing literature reporting that having a bedroom television set may be detrimental to young elementary school children. It also suggests that having and using a home computer may be associated with better academic achievement.
Neureiter, Elisabeth; Hajfani, Loreen; Ahnis, Anne; Mierke, Annett; Rose, Matthias; Danzer, Gerhard; Klapp, Burghard F
2017-01-01
Using a standardized instrument to evaluate patients' stress reactions has become more important in daily clinical routines. Different signs or symptoms of stress are often unilaterally explored: the physiological, psychological or social aspects of stress disorders are each viewed on a single dimension. However, all dimensions afflict patients who have persistent health problems due to chronic stress. Therefore, it is important to use a multidimensional approach to acquire data. The 'Psycho-Physiological-Stress-Test' (PPST) was established to achieve a comprehensive understanding of stress and was further developed at the Charité-Universitätsmedizin Berlin in collaboration with the Psychological Department of Freie Universität Berlin. The PPST includes a series of varying stress phases, embedded in two periods of rest. Physiological and psychological parameters are simultaneously measured throughout the test session. Specifically, the PPST activates the sympathetic stress axis, which is measured by heart rate, blood pressure, respiration depth and rate, electro dermal activation and muscle tension (frontalis, masseter, trapezius). Psychological data are simultaneously collected, and include performance, motivation, emotion and behavior. After conducting this diagnostic test, it is possible to identify individual stress patterns that can be discussed with the individual patient to develop and recommend (outpatient) treatment strategies. This paper introduces the PPST as a standardized way to evaluate stress reactions by presenting the results from a sample of psychosomatic inpatients (n = 139) who were treated in Charité-Universitätsmedizin Berlin, Germany. We observed that the varying testing conditions provoked adjusted changes in the different physiological parameters and psychological levels.
Bolong, Wu; Fengxia, Zhang; Xiaoning, Ma; Fengjuan, Zhou; Brunelle, Sharon L
2016-01-01
A potentiometric method for determination of chloride was validated against AOAC Standard Method Performance Requirement (SMPR(®)) 2014.015. Ten AOAC Stakeholder Panel on Infant Formula and Adult Nutritionals (SPIFAN) matrixes, including National Institute of Standards and Technology (NIST) Standard Reference Material (SRM) 1849a, were tested in duplicate on 6 independent days. The repeatability (RSDr) ranged from 0.43 to 1.34%, and the intermediate reproducibility (RSDiR) ranged from 0.80 to 3.04%. All results for NIST SRM 1849a were within the range of the certified concentration (701 ± 17 mg/100 g). Recovery was demonstrated with two overspike levels, 50 and 100%, in the 10 SPIFAN matrixes. Samples were tested in duplicate on 3 different days, and all results were within the SMPR requirement of 95 to 105%. The LOQs of the method for powdered products and ready-to-feed or reconstituted products were 20 mg/100 g and 2.2 mg/100 mL, respectively. A wide analytical range from the LOQ to 99.5% chlorine content can be reached with an appropriate dilution factor, but in practice, the upper analytical value observed in routine matrix testing was approximately 1080 mg/100 g in skim milk powder. This is a rapid, simple, and reliable chlorine-testing method applicable to infant formula, adult nutritionals, and ingredients used in these dairy-based products, such as skim milk powder, desalted whey powder, whey protein powder, and whole milk powder.
Further Testing of an Amine-based Pressure-Swing System for Carbon Dioxide and Humidity Control
NASA Technical Reports Server (NTRS)
Lin, Amy; Smith, Frederick; Sweterlitsch, Jeffrey; Nalette, Tim A.; Papale, William
2008-01-01
In a crewed spacecraft environment, atmospheric carbon dioxide (CO2) and moisture control are crucial. Hamilton Sundstrand has developed a stable and efficient amine-based CO2 and water vapor sorbent, SA9T, that is well suited for use in a spacecraft environment. The sorbent is efficiently packaged in pressure-swing regenerable beds that are thermally linked to improve removal efficiency and minimize vehicle thermal loads. Flows are all controlled with a single spool valve. This technology has been baselined for the new Orion spacecraft. However, more data was needed on the operational characteristics of the package in a simulated spacecraft environment. A unit was therefore tested with simulated metabolic loads in a closed chamber at Johnson Space Center during the last third of 2006. Those test results were reported in a 2007 ICES paper. A second test article was incorporated for a third phase of testing, and that test article was modified to allow pressurized gas purge regeneration on the launch pad in addition to the standard vacuum regeneration in space. Metabolic rates and chamber volumes were also adjusted to reflect current programmatic standards. The third phase of tests was performed during the spring and summer of 2007. Tests were run with a range of operating conditions, varying: cycle time, vacuum pressure (or purge gas flow rate), air flow rate, and crew activity levels. Results of this testing are presented and potential flight operational strategies discussed.
Emerson, Jane F; Emerson, Scott S
2005-01-01
A standardized urinalysis and manual microscopic cell counting system was evaluated for its potential to reduce intra- and interoperator variability in urine and cerebrospinal fluid (CSF) cell counts. Replicate aliquots of pooled specimens were submitted blindly to technologists who were instructed to use either the Kova system with the disposable Glasstic slide (Hycor Biomedical, Inc., Garden Grove, CA) or the standard operating procedure of the University of California-Irvine (UCI), which uses plain glass slides for urine sediments and hemacytometers for CSF. The Hycor system provides a mechanical means of obtaining a fixed volume of fluid in which to resuspend the sediment, and fixes the volume of specimen to be microscopically examined by using capillary filling of a chamber containing in-plane counting grids. Ninety aliquots of pooled specimens of each type of body fluid were used to assess the inter- and intraoperator reproducibility of the measurements. The variability of replicate Hycor measurements made on a single specimen by the same or different observers was compared with that predicted by a Poisson distribution. The Hycor methods generally resulted in test statistics that were slightly lower than those obtained with the laboratory standard methods, indicating a trend toward decreasing the effects of various sources of variability. For 15 paired aliquots of each body fluid, tests for systematically higher or lower measurements with the Hycor methods were performed using the Wilcoxon signed-rank test. Also examined was the average difference between the Hycor and current laboratory standard measurements, along with a 95% confidence interval (CI) for the true average difference. Without increasing labor or the requirement for attention to detail, the Hycor method provides slightly better interrater comparisons than the current method used at UCI. Copyright 2005 Wiley-Liss, Inc.
Microbial ingrowth around single- and multi-component adhesives studied in vitro.
Preussker, S; Klimm, W; Pöschmann, M; Koch, R
2003-01-01
The aim of this study was to compare the in vitro microbial leakage in 4 micro-hybrid composites in combination with 4 single-component dental adhesives (Scotchbond 1/Z100 MP = group 1; Syntac Single-Component/Tetric Flow = group 3; OptiBond Solo/XRV Herculite = group 5; Solobond M/Arabesk Top = group 7) and 4 multi-component dental adhesives (Scotchbond Multi-Purpose/Z100 MP = group 2; Syntac/Tetric Flow = group 4; OptiBond FL/XRV Herculite = group 6; Solobond Plus/Arabesk Top = group 8). Ninety-four mixed standardized Class V cavities of human caries-free extracted premolars were filled with eight different composite adhesive systems using a one-layer (groups 1-4) or a two-layer technique (groups 5-8). After thermocycling and incubation in a broth culture of Streptococcus mutans and Lactobacillus acidophilus, followed by decalcification and staining, the extent and the type of microbial leakage were measured histologically. The extent of microbial leakage in the composite restorations was very low in all groups and there were no significant differences between adhesives. Z100 MP in combination with single- and multi-component adhesives showed a significantly higher microbial leakage than Tetric Flow systems (U test: p=0.037). XRV Herculite adhesive systems showed significantly less extensive microbial leakage than Arabesk Top adhesive systems (U test: p<0.001). The single-component dental adhesives achieved a marginal adaptation of composites comparable to that of multi-component adhesives in vitro. Copyright 2003 S. Karger AG, Basel
Noninvasive Prenatal Diagnosis of Single-Gene Disorders by Use of Droplet Digital PCR.
Camunas-Soler, Joan; Lee, Hojae; Hudgins, Louanne; Hintz, Susan R; Blumenfeld, Yair J; El-Sayed, Yasser Y; Quake, Stephen R
2018-02-01
Prenatal diagnosis in pregnancies at risk of single-gene disorders is currently performed using invasive methods such as chorionic villus sampling and amniocentesis. This is in contrast with screening for common aneuploidies, for which noninvasive methods with a single maternal blood sample have become standard clinical practice. We developed a protocol for noninvasive prenatal diagnosis of inherited single-gene disorders using droplet digital PCR from circulating cell-free DNA (cfDNA) in maternal plasma. First, the amount of cfDNA and fetal fraction is determined using a panel of TaqMan assays targeting high-variability single-nucleotide polymorphisms. Second, the ratio of healthy and diseased alleles in maternal plasma is quantified using TaqMan assays targeting the mutations carried by the parents. Two validation approaches of the mutation assay are presented. We collected blood samples from 9 pregnancies at risk for different single-gene disorders, including common conditions and rare metabolic disorders. We measured cases at risk of hemophilia, ornithine transcarbamylase deficiency, cystic fibrosis, β-thalassemia, mevalonate kinase deficiency, acetylcholine receptor deficiency, and DFNB1 nonsyndromic hearing loss. We correctly differentiated affected and unaffected pregnancies (2 affected, 7 unaffected), confirmed by neonatal testing. We successfully measured an affected pregnancy as early as week 11 and with a fetal fraction as low as 3.7% (0.3). Our method detects single-nucleotide mutations of autosomal recessive diseases as early as the first trimester of pregnancy. This is of importance for metabolic disorders in which early diagnosis can affect management of the disease and reduce complications and anxiety related to invasive testing. © 2017 American Association for Clinical Chemistry.
Frickmann, H; Schwarz, N G; Hahn, A; Ludyga, A; Warnke, P; Podbielski, A
2018-05-01
Success of methicillin-resistant Staphylococcus aureus (MRSA) decolonization procedures is usually verified by control swabs of the colonized body region. This prospective controlled study compared a single-day regimen with a well-established 3-day scheme for noninferiority and adherence to the testing scheme. Two sampling schemes for screening MRSA patients of a single study cohort at a German tertiary-care hospital 2 days after decolonization were compared regarding their ability to identify MRSA colonization in throat or nose. In each patient, three nose and three throat swabs were taken at 3- to 4-hour intervals during screening day 1, and in the same patients once daily on days 1, 2 and 3. Swabs were analysed using chromogenic agar and broth enrichment. The study aimed to investigate whether the single-day swabbing scheme is not inferior to the 3-day scheme with a 15% noninferiority margin. One hundred sixty patients were included, comprising 105 and 101 patients with results on all three swabs for decolonization screening of the nose and throat, respectively. Noninferiority of the single-day swabbing scheme was confirmed for both pharyngeal and nasal swabs, with 91.8% and 89% agreement, respectively. The absolute difference of positivity rates between the swabbing regimens was 0.025 (-0.082, 0.131) for the nose and 0.006 (-0.102, 0.114) (95% confidence interval) for the pharynx as calculated with McNemar's test for matched or paired data. Compliance with the single-day scheme was better, with 12% lacking second-day swabs and 27% lacking third-day swabs from the nostrils. The better adherence to the single-day screening scheme with noninferiority suggests its implementation as the new gold standard. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.
7 CFR 43.104 - Master table of single and double sampling plans.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 7 Agriculture 2 2012-01-01 2012-01-01 false Master table of single and double sampling plans. 43... STANDARD CONTAINER REGULATIONS STANDARDS FOR SAMPLING PLANS Sampling Plans § 43.104 Master table of single and double sampling plans. (a) In the master table, a sampling plan is selected by first determining...
7 CFR 43.104 - Master table of single and double sampling plans.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 7 Agriculture 2 2013-01-01 2013-01-01 false Master table of single and double sampling plans. 43... STANDARD CONTAINER REGULATIONS STANDARDS FOR SAMPLING PLANS Sampling Plans § 43.104 Master table of single and double sampling plans. (a) In the master table, a sampling plan is selected by first determining...
7 CFR 43.104 - Master table of single and double sampling plans.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 7 Agriculture 2 2014-01-01 2014-01-01 false Master table of single and double sampling plans. 43... STANDARD CONTAINER REGULATIONS STANDARDS FOR SAMPLING PLANS Sampling Plans § 43.104 Master table of single and double sampling plans. (a) In the master table, a sampling plan is selected by first determining...
7 CFR 43.104 - Master table of single and double sampling plans.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 7 Agriculture 2 2011-01-01 2011-01-01 false Master table of single and double sampling plans. 43... STANDARD CONTAINER REGULATIONS STANDARDS FOR SAMPLING PLANS Sampling Plans § 43.104 Master table of single and double sampling plans. (a) In the master table, a sampling plan is selected by first determining...
Microscopic assessment of the sealing ability of three endodontic filling techniques
Cueva-Goig, Roger; Llena-Puy, Mª Carmen
2016-01-01
Background Several techniques have been proposed for root canal filling. New rotary files, with non-standardized taper, are appearing, so, points adapted to the taper of the last instrument used to prepare the canal can help in the obturation process. The aim of this study is to assess the sealing ability of different root canal filling techniques. Material and Methods Root canals from 30 teeth were shaped with Mtwo and divided in three groups; A, standard lateral condensation with size 35 and 20 gutta-percha points; B, standard lateral condensation and injected gutta-percha; C, single gutta-percha point (standardized 35 Mtwo), continuous wave technique and injected gutta-percha. Root surfaces were covered with nail varnish, except for the apical 2 mm, and submerged in a NO3Ag2 solution; apical stain penetration was measured in mm. Data were compared using the Kruskal-Wallis test with a 90% confidence interval. Results A and B groups showed stain leakage in the 90% of the cases, whereas it was of 80% for group C. Stain leakage intervals were 1-5 mm for groups A and B and 1-3 mm for group C. There were no statistically significant differences between the three studied groups (p>.05). Conclusions All the analyzed root canal filling techniques showed some apical stain leakage, without significant differences among them. Key words:Gutta-percha filling, microleakage, single cone, injected gutta-percha, warm gutta-percha. PMID:26855702
DOE Office of Scientific and Technical Information (OSTI.GOV)
?Ventilation system effectiveness testing was conducted at two unoccupied, single-family, detached lab homes at the University of Texas - Tyler. Five ventilation system tests were conducted with various whole-building ventilation systems. Multizone fan pressurization testing characterized building and zone enclosure leakage. PFT testing showed multizone air change rates and interzonal airflow filtration. Indoor air recirculation by a central air distribution system can help improve the exhaust ventilation system by way of air mixing and filtration. In contrast, the supply and balanced ventilation systems showed that there is a significant benefit to drawing outside air from a known outside location, andmore » filtering and distributing that air. Compared to the Exhaust systems, the CFIS and ERV systems showed better ventilation air distribution and lower concentrations of particulates, formaldehyde and other VOCs. System improvement percentages were estimated based on four System Factor Categories: Balance, Distribution, Outside Air Source, and Recirculation Filtration. Recommended System Factors could be applied to reduce ventilation fan airflow rates relative to ASHRAE Standard 62.2 to save energy and reduce moisture control risk in humid climates. HVAC energy savings were predicted to be 8-10%, or $50-$75/year. Cumulative particle counts for six particle sizes, and formaldehyde and other Top 20 VOC concentrations were measured in multiple zones. The testing showed that single-point exhaust ventilation was inferior as a whole-house ventilation strategy.« less
ERIC Educational Resources Information Center
Ugille, Maaike; Moeyaert, Mariola; Beretvas, S. Natasha; Ferron, John M.; Van den Noortgate, Wim
2014-01-01
A multilevel meta-analysis can combine the results of several single-subject experimental design studies. However, the estimated effects are biased if the effect sizes are standardized and the number of measurement occasions is small. In this study, the authors investigated 4 approaches to correct for this bias. First, the standardized effect…
An extension of the standard model with a single coupling parameter
NASA Astrophysics Data System (ADS)
Atance, Mario; Cortés, José Luis; Irastorza, Igor G.
1997-02-01
We show that it is possible to find an extension of the matter content of the standard model with a unification of gauge and Yukawa couplings reproducing their known values. The perturbative renormalizability of the model with a single coupling and the requirement to accommodate the known properties of the standard model fix the masses and couplings of the additional particles. The implications on the parameters of the standard model are discussed.
The correlation between relatives on the supposition of genomic imprinting.
Spencer, Hamish G
2002-01-01
Standard genetic analyses assume that reciprocal heterozygotes are, on average, phenotypically identical. If a locus is subject to genomic imprinting, however, this assumption does not hold. We incorporate imprinting into the standard quantitative-genetic model for two alleles at a single locus, deriving expressions for the additive and dominance components of genetic variance, as well as measures of resemblance among relatives. We show that, in contrast to the case with Mendelian expression, the additive and dominance deviations are correlated. In principle, this correlation allows imprinting to be detected solely on the basis of different measures of familial resemblances, but in practice, the standard error of the estimate is likely to be too large for a test to have much statistical power. The effects of genomic imprinting will need to be incorporated into quantitative-genetic models of many traits, for example, those concerned with mammalian birthweight. PMID:12019254
The correlation between relatives on the supposition of genomic imprinting.
Spencer, Hamish G
2002-05-01
Standard genetic analyses assume that reciprocal heterozygotes are, on average, phenotypically identical. If a locus is subject to genomic imprinting, however, this assumption does not hold. We incorporate imprinting into the standard quantitative-genetic model for two alleles at a single locus, deriving expressions for the additive and dominance components of genetic variance, as well as measures of resemblance among relatives. We show that, in contrast to the case with Mendelian expression, the additive and dominance deviations are correlated. In principle, this correlation allows imprinting to be detected solely on the basis of different measures of familial resemblances, but in practice, the standard error of the estimate is likely to be too large for a test to have much statistical power. The effects of genomic imprinting will need to be incorporated into quantitative-genetic models of many traits, for example, those concerned with mammalian birthweight.
Quantification of HIV-1 DNA using real-time recombinase polymerase amplification.
Crannell, Zachary Austin; Rohrman, Brittany; Richards-Kortum, Rebecca
2014-06-17
Although recombinase polymerase amplification (RPA) has many advantages for the detection of pathogenic nucleic acids in point-of-care applications, RPA has not yet been implemented to quantify sample concentration using a standard curve. Here, we describe a real-time RPA assay with an internal positive control and an algorithm that analyzes real-time fluorescence data to quantify HIV-1 DNA. We show that DNA concentration and the onset of detectable amplification are correlated by an exponential standard curve. In a set of experiments in which the standard curve and algorithm were used to analyze and quantify additional DNA samples, the algorithm predicted an average concentration within 1 order of magnitude of the correct concentration for all HIV-1 DNA concentrations tested. These results suggest that quantitative RPA (qRPA) may serve as a powerful tool for quantifying nucleic acids and may be adapted for use in single-sample point-of-care diagnostic systems.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gao, J; Liu, X
2016-06-15
Purpose: To perform a quantitative study to verify that the mechanical field center coincides with the radiation field center when both are off from the isocenter during the single-isocenter technique in linear accelerator-based SRS/SBRT procedure to treat multiple lesions. Methods: We developed an innovative method to measure this accuracy, called the off-isocenter Winston-Lutz test, and here we provide a practical clinical guideline to implement this technique. We used ImagePro V.6 to analyze images of a Winston-Lutz phantom obtained using a Varian 21EX linear accelerator with an electronic portal imaging device, set up as for single-isocenter SRS/SBRT for multiple lesions. Wemore » investigated asymmetry field centers that were 3 cm and 5 cm away from the isocenter, as well as performing the standard Winston-Lutz test. We used a special beam configuration to acquire images while avoiding collision, and we investigated both jaw and multileaf collimation. Results: For the jaw collimator setting, at 3 cm off-isocenter, the mechanical field deviated from the radiation field by about 2.5 mm; at 5 cm, the deviation was above 3 mm, up to 4.27 mm. For the multileaf collimator setting, at 3 cm off-isocenter, the deviation was below 1 mm; at 5 cm, the deviation was above 1 mm, up to 1.72 mm, which is 72% higher than the tolerance threshold. Conclusion: These results indicated that the further the asymmetry field center is from the machine isocenter, the larger the deviation of the mechanical field from the radiation field, and the distance between the center of the asymmetry field and the isocenter should not exceed 3 cm in of our clinic. We recommend that every clinic that uses linear accelerator, multileaf collimator-based SRS/SBRT perform the off-isocenter Winston-Lutz test in addition to the standard Winston-Lutz test and use their own deviation data to design the treatment plan.« less
Arain, Nabeel A; Cadeddu, Jeffrey A; Best, Sara L; Roshek, Thomas; Chang, Victoria; Hogg, Deborah C; Bergs, Richard; Fernandez, Raul; Webb, Erin M; Scott, Daniel J
2012-04-01
This study aimed to evaluate the surgeon performance and workload of a next-generation magnetically anchored camera compared with laparoscopic and flexible endoscopic imaging systems for laparoscopic and single-site laparoscopy (SSL) settings. The cameras included a 5-mm 30° laparoscope (LAP), a magnetically anchored (MAGS) camera, and a flexible endoscope (ENDO). The three camera systems were evaluated using standardized optical characteristic tests. Each system was used in random order for visualization during performance of a standardized suturing task by four surgeons. Each participant performed three to five consecutive repetitions as a surgeon and also served as a camera driver for other surgeons. Ex vivo testing was conducted in a laparoscopic multiport and SSL layout using a box trainer. In vivo testing was performed only in the multiport configuration and used a previously validated live porcine Nissen model. Optical testing showed superior resolution for MAGS at 5 and 10 cm compared with LAP or ENDO. The field of view ranged from 39 to 99°. The depth of focus was almost three times greater for MAGS (6-270 mm) than for LAP (2-88 mm) or ENDO (1-93 mm). Both ex vivo and in vivo multiport combined surgeon performance was significantly better for LAP than for ENDO, but no significant differences were detected for MAGS. For multiport testing, workload ratings were significantly less ex vivo for LAP and MAGS than for ENDO and less in vivo for LAP than for MAGS or ENDO. For ex vivo SSL, no significant performance differences were detected, but camera drivers rated the workload significantly less for MAGS than for LAP or ENDO. The data suggest that the improved imaging element of the next-generation MAGS camera has optical and performance characteristics that meet or exceed those of the LAP or ENDO systems and that the MAGS camera may be especially useful for SSL. Further refinements of the MAGS camera are encouraged.
MEDIPIX: a VLSI chip for a GaAs pixel detector for digital radiology
NASA Astrophysics Data System (ADS)
Amendolia, S. R.; Bertolucci, E.; Bisogni, M. G.; Bottigli, U.; Ceccopieri, A.; Ciocci, M. A.; Conti, M.; Delogu, P.; Fantacci, M. E.; Maestro, P.; Marzulli, V.; Pernigotti, E.; Romeo, N.; Rosso, V.; Rosso, P.; Stefanini, A.; Stumbo, S.
1999-02-01
A GaAs pixel detector designed for digital mammography, equipped with a 36-channel single photon counting discrete read-out electronics, was tested using a test object developed for quality control purposes in mammography. Each pixel was 200×200 μm 2 large, and 200 μm deep. The choice of GaAs with respect to silicon (largely used in other applications and with a more established technique) has been made because of the much better detection efficiency at mammographic energies, combined with a very good charge collection efficiency achieved thanks to new ohmic contacts. This GaAs detector is able to perform a measurement of low-contrast details, with minimum contrast lower (nearly a factor two) than that typically achievable with standard mammographic film+screen systems in the same conditions of clinical routine. This should allow for an earlier diagnosis of breast tumour masses. Due to these encouraging results, the next step in the evolution of our imaging system based on GaAs detectors has been the development of a VLSI front-end prototype chip (MEDIPIX ) in order to cover a much larger diagnostic area. The chip reads 64×64 channels in single photon counting mode, each one 170 μm wide. Each channel contains also a test input where a signal can be simulated, injecting a known charge through a 16 f F capacitor. Fake signals have been injected via the test input measuring and equalizing minimum thresholds for all the channels. On an average, in most of the performing chips available up to now, we have found that it is possible to set a threshold as low as 1800 electrons with an RMS of 150 electrons (10 standard deviations lower than the 20 keV photon signal roughly equivalent to 4500 electrons). The detector, bump-bonded to the chip, will be tested and a ladder of detectors will be prepared to be able to scan large surface objects.
Classifying multispectral data by neural networks
NASA Technical Reports Server (NTRS)
Telfer, Brian A.; Szu, Harold H.; Kiang, Richard K.
1993-01-01
Several energy functions for synthesizing neural networks are tested on 2-D synthetic data and on Landsat-4 Thematic Mapper data. These new energy functions, designed specifically for minimizing misclassification error, in some cases yield significant improvements in classification accuracy over the standard least mean squares energy function. In addition to operating on networks with one output unit per class, a new energy function is tested for binary encoded outputs, which result in smaller network sizes. The Thematic Mapper data (four bands were used) is classified on a single pixel basis, to provide a starting benchmark against which further improvements will be measured. Improvements are underway to make use of both subpixel and superpixel (i.e. contextual or neighborhood) information in tile processing. For single pixel classification, the best neural network result is 78.7 percent, compared with 71.7 percent for a classical nearest neighbor classifier. The 78.7 percent result also improves on several earlier neural network results on this data.
Changes of propagation light in optical fiber submicron wires
NASA Astrophysics Data System (ADS)
Stasiewicz, K. A.; Łukowski, A.; Jaroszewicz, L. R.
2013-05-01
At the moment technology allows to miniaturize measurement system to several micrometers. Application of an optical fiber taper in such system needs to manufacture a new one with diameters below single micrometers which is very difficult and expensive. Another way to obtain this level of diameters is the process of tapering from the existing fibers. In the paper, experimental results of propagation light from a supercontinnum sources of the wavelength generates the wavelength of 350-2000 nm, in different optical fiber submicron wires made from tapers manufactured from single mode fibers are presented. Biconical optical fibers' tapers were manufactured in low pressure gas burner technique. There are presented spectral characteristics of a propagated beam. For the test, there was manufactured an optical fiber submicron wires with a different length of waist region with a diameter near one micrometer. We put to the test a taper made from a standard telecommunication fiber SMF-28 with a cutoff wavelength equal to 1260.
Performance of a green propellant thruster with discharge plasma
NASA Astrophysics Data System (ADS)
Shindo, Takahiro; Wada, Asato; Maeda, Hiroshi; Watanabe, Hiroki; Takegahara, Haruki
2017-02-01
A discharge plasma was applied to initiate the combustion of a hydroxylammonium nitrate-based propellant as a substitute for the catalysts that are typically employed. The resulting thrust and thrust-to-power ratio during short interval firing tests as well as the chamber pressure with a single pulse discharge were evaluated. A 1.5-s firing test generated a maximum thrust of 322 mN along with a thrust-to-power ratio of 0.95 mN/W. During the single-pulse discharge trials, pulsed discharge capacitor energies of 5.4, 10.8, and 16.4 J were assessed, and the maximum chamber pressure was found to increase as the energy was raised. The maximum chamber pressures varied widely between experimental trials, and a 16.4-J energy value resulted in the highest chamber pressure of over 1 MPaG. The time spans between the pulsed discharge and the peak chamber pressure were in the range of 1-2 ms, representing a chamber pressure increase rate much higher than those obtained with standard catalysts.