Marheineke, Nadine; Scherer, Uta; Rücker, Martin; von See, Constantin; Rahlf, Björn; Gellrich, Nils-Claudius; Stoetzer, Marcus
2018-06-01
Dental implant failure and insufficient osseointegration are proven results of mechanical and thermal damage during the surgery process. We herein performed a comparative study of a less invasive single-step drilling preparation protocol and a conventional multiple drilling sequence. Accuracy of drilling holes was precisely analyzed and the influence of different levels of expertise of the handlers and additional use of drill template guidance was evaluated. Six experimental groups, deployed in an osseous study model, were representing template-guided and freehanded drilling actions in a stepwise drilling procedure in comparison to a single-drill protocol. Each experimental condition was studied by the drilling actions of respectively three persons without surgical knowledge as well as three highly experienced oral surgeons. Drilling actions were performed and diameters were recorded with a precision measuring instrument. Less experienced operators were able to significantly increase the drilling accuracy using a guiding template, especially when multi-step preparations are performed. Improved accuracy without template guidance was observed when experienced operators were executing single-step versus multi-step technique. Single-step drilling protocols have shown to produce more accurate results than multi-step procedures. The outcome of any protocol can be further improved by use of guiding templates. Operator experience can be a contributing factor. Single-step preparations are less invasive and are promoting osseointegration. Even highly experienced surgeons are achieving higher levels of accuracy by combining this technique with template guidance. Hereby template guidance enables a reduction of hands-on time and side effects during surgery and lead to a more predictable clinical diameter.
NASA Astrophysics Data System (ADS)
Sham, Atiyah W. M.; Monsi, Mansor; Hassan, Nasruddin; Suleiman, Mohamed
2013-04-01
The aim of this paper is to present a new modified interval symmetric single-step procedure ISS-5D which is the extension from the previous procedure, ISS1. The ISS-5D method will produce successively smaller intervals that are guaranteed to still contain the zeros. The efficiency of this method is measured on the CPU times and the number of iteration. The procedure is run on five test polynomials and the results obtained are shown in this paper.
Azar, Nabih; Leblond, Veronique; Ouzegdouh, Maya; Button, Paul
2017-12-01
The Pitié Salpêtrière Hospital Hemobiotherapy Department, Paris, France, has been providing extracorporeal photopheresis (ECP) since November 2011, and started using the Therakos ® CELLEX ® fully integrated system in 2012. This report summarizes our single-center experience of transitioning from the use of multi-step ECP procedures to the fully integrated ECP system, considering the capacity and cost implications. The total number of ECP procedures performed 2011-2015 was derived from department records. The time taken to complete a single ECP treatment using a multi-step technique and the fully integrated system at our department was assessed. Resource costs (2014€) were obtained for materials and calculated for personnel time required. Time-driven activity-based costing methods were applied to provide a cost comparison. The number of ECP treatments per year increased from 225 (2012) to 727 (2015). The single multi-step procedure took 270 min compared to 120 min for the fully integrated system. The total calculated per-session cost of performing ECP using the multi-step procedure was greater than with the CELLEX ® system (€1,429.37 and €1,264.70 per treatment, respectively). For hospitals considering a transition from multi-step procedures to fully integrated methods for ECP where cost may be a barrier, time-driven activity-based costing should be utilized to gain a more comprehensive understanding the full benefit that such a transition offers. The example from our department confirmed that there were not just cost and time savings, but that the time efficiencies gained with CELLEX ® allow for more patient treatments per year. © 2017 The Authors Journal of Clinical Apheresis Published by Wiley Periodicals, Inc.
Wang, Shan-Jin; Han, Ying-Chao; Pan, Fu-Min; Ma, Bin; Tan, Jun
2015-01-01
Single transverse cage placed in the anterior vertebral column can better maintain lumbar lordosis and sagittal alignment and is frequently used via the lateral transpsoas approach. However, there is no clear description in the literature of the steps required to place the single transverse cage during the instrumented transforaminal lumbar interbody fusion (TLIF) procedure for the treatment of degenerative lumbar disease. The objective of this study is to describe the technique using single transverse-orientation cage when performing TLIF procedures. We present 18 illustrative cases in which single transverse-orientation cage was placed according to a step-by-step technique that can be used during the TLIF procedure. Information acquired included procedure time, intraoperative blood loss and postoperative complications. The preoperative and postoperative Oswestry Disability Index (ODI) and the visual analogue scale (VAS) scores were recorded. Changes in disc height and segmental lordosis were measured at radiographs. The single transverse-orientation cage was successfully placed in 18 patients in a stepwise technique to achieve lumbar fusion. Using this technique, the patients significantly improved clinically and radiographically at postoperative visits. This is the first report demonstrating the safety and efficacy of instrumented TLIF with single transverse-orientation cage for the treatment of degenerative lumbar disease. Single transverse-orientation cage via MIS-TLIF approach can maintain greater lumbar lordosis and avoid the unique complications of lateral transpsoas approach. Understanding the options for cage placement is important for surgeons considering the use of this technique.
Measurement of intrahepatic pressure during radiofrequency ablation in porcine liver.
Kawamoto, Chiaki; Yamauchi, Atsushi; Baba, Yoko; Kaneko, Keiko; Yakabi, Koji
2010-04-01
To identify the most effective procedures to avoid increased intrahepatic pressure during radiofrequency ablation, we evaluated different ablation methods. Laparotomy was performed in 19 pigs. Intrahepatic pressure was monitored using an invasive blood pressure monitor. Radiofrequency ablation was performed as follows: single-step standard ablation; single-step at 30 W; single-step at 70 W; 4-step at 30 W; 8-step at 30 W; 8-step at 70 W; and cooled-tip. The array was fully deployed in single-step methods. In the multi-step methods, the array was gradually deployed in four or eight steps. With the cooled-tip, ablation was performed by increasing output by 10 W/min, starting at 40 W. Intrahepatic pressure was as follows: single-step standard ablation, 154.5 +/- 30.9 mmHg; single-step at 30 W, 34.2 +/- 20.0 mmHg; single-step at 70 W, 46.7 +/- 24.3 mmHg; 4-step at 30 W, 42.3 +/- 17.9 mmHg; 8-step at 30 W, 24.1 +/- 18.2 mmHg; 8-step at 70 W, 47.5 +/- 31.5 mmHg; and cooled-tip, 114.5 +/- 16.6 mmHg. The radiofrequency ablation-induced area was spherical with single-step standard ablation, 4-step at 30 W, and 8-step at 30 W. Conversely, the ablated area was irregular with single-step at 30 W, single-step at 70 W, and 8-step at 70 W. The ablation time was significantly shorter for the multi-step method than for the single-step method. Increased intrahepatic pressure could be controlled using multi-step methods. From the shapes of the ablation area, 30-W 8-step expansions appear to be most suitable for radiofrequency ablation.
Using a Five-Step Procedure for Inferential Statistical Analyses
ERIC Educational Resources Information Center
Kamin, Lawrence F.
2010-01-01
Many statistics texts pose inferential statistical problems in a disjointed way. By using a simple five-step procedure as a template for statistical inference problems, the student can solve problems in an organized fashion. The problem and its solution will thus be a stand-by-itself organic whole and a single unit of thought and effort. The…
Redo Laparoscopic Gastric Bypass: One-Step or Two-Step Procedure?
Theunissen, Caroline M J; Guelinckx, Nele; Maring, John K; Langenhoff, Barbara S
2016-11-01
The adjustable gastric band (AGB) is a bariatric procedure that used to be widely performed. However, AGB failure-signifying band-related complications or unsatisfactory weight loss, resulting in revision surgery (redo operations)-frequently occurs. Often this entails a conversion to a laparoscopic Roux-en-Y gastric bypass (LRYGB). This can be performed as a one-step or two-step (separate band removal) procedure. Data were collected from patients operated from 2012 to 2014 in a single bariatric centre. We compared 107 redo LRYGB after AGB failure with 1020 primary LRYGB. An analysis was performed of the one-step vs. two-step redo procedures. All redo procedures were performed by experienced bariatric surgeons. No difference in major complication rate was seen (2.8 vs. 2.3 %, p = 0.73) between redo and primary LRYGB, and overall complication severity for redos was low (mainly Clavien-Dindo 1 or 2). Weight loss results were comparable for primary and redo procedures. The one-step and two-step redos were comparable regarding complication rates and readmissions. The operating time for the one-step redo LRYGB was 136 vs. 107.5 min for the two-step (median, p < 0.001), excluding the operating time of separate AGB removal (mean 61 min, range 36-110). Removal of a failed AGB and LRYGB in a one-step procedure is safe when performed by experienced bariatric surgeons. However, when erosion or perforation of the AGB occurs, we advise caution and would perform the redo LRYGB as a two-step procedure. Equal weights can be achieved at 1 year post redo LRYGB as after primary LRYGB procedures.
Single Sheet Agricultural Mechanics Plans.
ERIC Educational Resources Information Center
Schumacher, Leon, Ed.
This packet contains 25 single-page plans for agricultural mechanics projects. Each plan consists of a one-page set of drawings of the object to be made with a list of needed materials, a cut list, and step-by-step construction procedures on the back of the page. Plans for the following wood projects are included: bluebird house, lawn seat, dog…
Leblond, Veronique; Ouzegdouh, Maya; Button, Paul
2017-01-01
Abstract Introduction The Pitié Salpêtrière Hospital Hemobiotherapy Department, Paris, France, has been providing extracorporeal photopheresis (ECP) since November 2011, and started using the Therakos® CELLEX® fully integrated system in 2012. This report summarizes our single‐center experience of transitioning from the use of multi‐step ECP procedures to the fully integrated ECP system, considering the capacity and cost implications. Materials and Methods The total number of ECP procedures performed 2011–2015 was derived from department records. The time taken to complete a single ECP treatment using a multi‐step technique and the fully integrated system at our department was assessed. Resource costs (2014€) were obtained for materials and calculated for personnel time required. Time‐driven activity‐based costing methods were applied to provide a cost comparison. Results The number of ECP treatments per year increased from 225 (2012) to 727 (2015). The single multi‐step procedure took 270 min compared to 120 min for the fully integrated system. The total calculated per‐session cost of performing ECP using the multi‐step procedure was greater than with the CELLEX® system (€1,429.37 and €1,264.70 per treatment, respectively). Conclusions For hospitals considering a transition from multi‐step procedures to fully integrated methods for ECP where cost may be a barrier, time‐driven activity‐based costing should be utilized to gain a more comprehensive understanding the full benefit that such a transition offers. The example from our department confirmed that there were not just cost and time savings, but that the time efficiencies gained with CELLEX® allow for more patient treatments per year. PMID:28419561
Procedure for normalization of cDNA libraries
Bonaldo, Maria DeFatima; Soares, Marcelo Bento
1997-01-01
This invention provides a method to normalize a cDNA library constructed in a vector capable of being converted to single-stranded circles and capable of producing complementary nucleic acid molecules to the single-stranded circles comprising: (a) converting the cDNA library in single-stranded circles; (b) generating complementary nucleic acid molecules to the single-stranded circles; (c) hybridizing the single-stranded circles converted in step (a) with complementary nucleic acid molecules of step (b) to produce partial duplexes to an appropriate Cot; (e) separating the unhybridized single-stranded circles from the hybridized single-stranded circles, thereby generating a normalized cDNA library.
Direct Sensor Orientation of a Land-Based Mobile Mapping System
Rau, Jiann-Yeou; Habib, Ayman F.; Kersting, Ana P.; Chiang, Kai-Wei; Bang, Ki-In; Tseng, Yi-Hsing; Li, Yu-Hua
2011-01-01
A land-based mobile mapping system (MMS) is flexible and useful for the acquisition of road environment geospatial information. It integrates a set of imaging sensors and a position and orientation system (POS). The positioning quality of such systems is highly dependent on the accuracy of the utilized POS. This limitation is the major drawback due to the elevated cost associated with high-end GPS/INS units, particularly the inertial system. The potential accuracy of the direct sensor orientation depends on the architecture and quality of the GPS/INS integration process as well as the validity of the system calibration (i.e., calibration of the individual sensors as well as the system mounting parameters). In this paper, a novel single-step procedure using integrated sensor orientation with relative orientation constraint for the estimation of the mounting parameters is introduced. A comparative analysis between the proposed single-step and the traditional two-step procedure is carried out. Moreover, the estimated mounting parameters using the different methods are used in a direct geo-referencing procedure to evaluate their performance and the feasibility of the implemented system. Experimental results show that the proposed system using single-step system calibration method can achieve high 3D positioning accuracy. PMID:22164015
NASA Technical Reports Server (NTRS)
Chen, D. Y.; Owen, H. A., Jr.; Wilson, T. G.
1980-01-01
This paper presents an algorithm and equations for designing the energy-storage reactor for dc-to-dc converters which are constrained to operate in the discontinuous-reactor-current mode. This design procedure applied to the three widely used single-winding configurations: the voltage step-up, the current step-up, and the voltage-or-current step-up converters. A numerical design example is given to illustrate the use of the design algorithm and design equations.
Guan, Xiaoming; Ma, Yingchun; Gisseman, Jordan; Kleithermes, Christopher; Liu, Juan
2017-01-01
To demonstrate the tips and tricks of a simpler technique for single-site sacrocolpopexy using barbed suture anchoring and retroperitoneal tunneling to make the procedure more efficient and reproducible. Step-by-step description of surgical tutorial using a narrated video (Canadian Task Force classification III). Academic tertiary care hospital. Patient with Stage III uterine prolapse. Sacrocolpopexy is increasing utilized since the FDA warning about complications of vaginal mesh surgery. It is the gold standard for repair of apical prolapse. However, there is great variation in the sacrocolpopexy procedure techniques and they have not been standardized. Traditional single-site laparoscopic sacrocolpopexy is very challenging as the procedure time is long and suturing is difficult. The advantages of suturing with wristed needle drivers in robotic single-site surgery simplify this complex procedure. Furthermore, using barbed suture anchoring and peritoneal tunneling technique potentially decreases the surgeon's learning curve and makes the procedure reproducible. In this video, we demonstrate a supracervial hysterectomy with a stepwise explanation of the correct technique for performing a robotic single incision sacrocolpopexy. Sacrocolpopexy is increasing used since the US Food and Drug Administration warning about complications of vaginal mesh surgery. It is the gold standard for repair of apical prolapse. However, a great variation exists in the sacrocolpopexy procedure techniques that need to be standardized. Traditional single-site laparoscopic sacrocolpopexy is very challenging because the procedure time is long and suturing is difficult. The advantages of suturing with wristed needle drivers in robotic single-site surgery simplify this complex procedure. Furthermore, using the barbed suture anchoring and peritoneal tunneling technique potentially decreases the surgeon's learning curve and makes the procedure reproducible. In this video, we demonstrate a supracervical hysterectomy with a stepwise explaation of the correct technique for performing a robotic single-incision sacrocolpopexy. The possibility of using the barbed suture and peritoneal tunneling technique with wristed needle drivers in robotic single-site sacrocolpopexy offers the possibility of an effective, safe, reproducible, and cosmetic surgical option. Copyright © 2016 AAGL. Published by Elsevier Inc. All rights reserved.
Procedure for normalization of cDNA libraries
Bonaldo, M.D.; Soares, M.B.
1997-12-30
This invention provides a method to normalize a cDNA library constructed in a vector capable of being converted to single-stranded circles and capable of producing complementary nucleic acid molecules to the single-stranded circles comprising: (a) converting the cDNA library in single-stranded circles; (b) generating complementary nucleic acid molecules to the single-stranded circles; (c) hybridizing the single-stranded circles converted in step (a) with complementary nucleic acid molecules of step (b) to produce partial duplexes to an appropriate Cot; (e) separating the unhybridized single-stranded circles from the hybridized single-stranded circles, thereby generating a normalized cDNA library. 1 fig.
NASA Technical Reports Server (NTRS)
Huffman, S.
1977-01-01
Detailed instructions on the use of two computer-aided-design programs for designing the energy storage inductor for single winding and two winding dc to dc converters are provided. Step by step procedures are given to illustrate the formatting of user input data. The procedures are illustrated by eight sample design problems which include the user input and the computer program output.
Separation of Be and Al for AMS using single-step column chromatography
NASA Astrophysics Data System (ADS)
Binnie, Steven A.; Dunai, Tibor J.; Voronina, Elena; Goral, Tomasz; Heinze, Stefan; Dewald, Alfred
2015-10-01
With the aim of simplifying AMS target preparation procedures for TCN measurements we tested a new extraction chromatography approach which couples an anion exchange resin (WBEC) to a chelating resin (Beryllium resin) to separate Be and Al from dissolved quartz samples. Results show that WBEC-Beryllium resin stacks can be used to provide high purity Be and Al separations using a combination of hydrochloric/oxalic and nitric acid elutions. 10Be and 26Al concentrations from quartz samples prepared using more standard procedures are compared with results from replicate samples prepared using the coupled WBEC-Beryllium resin approach and show good agreement. The new column procedure is performed in a single step, reducing sample preparation times relative to more traditional methods of TCN target production.
Platelet-rich plasma differs according to preparation method and human variability.
Mazzocca, Augustus D; McCarthy, Mary Beth R; Chowaniec, David M; Cote, Mark P; Romeo, Anthony A; Bradley, James P; Arciero, Robert A; Beitzel, Knut
2012-02-15
Varying concentrations of blood components in platelet-rich plasma preparations may contribute to the variable results seen in recently published clinical studies. The purposes of this investigation were (1) to quantify the level of platelets, growth factors, red blood cells, and white blood cells in so-called one-step (clinically used commercial devices) and two-step separation systems and (2) to determine the influence of three separate blood draws on the resulting components of platelet-rich plasma. Three different platelet-rich plasma (PRP) separation methods (on blood samples from eight subjects with a mean age [and standard deviation] of 31.6 ± 10.9 years) were used: two single-spin processes (PRPLP and PRPHP) and a double-spin process (PRPDS) were evaluated for concentrations of platelets, red and white blood cells, and growth factors. Additionally, the effect of three repetitive blood draws on platelet-rich plasma components was evaluated. The content and concentrations of platelets, white blood cells, and growth factors for each method of separation differed significantly. All separation techniques resulted in a significant increase in platelet concentration compared with native blood. Platelet and white blood-cell concentrations of the PRPHP procedure were significantly higher than platelet and white blood-cell concentrations produced by the so-called single-step PRPLP and the so-called two-step PRPDS procedures, although significant differences between PRPLP and PRPDS were not observed. Comparing the results of the three blood draws with regard to the reliability of platelet number and cell counts, wide variations of intra-individual numbers were observed. Single-step procedures are capable of producing sufficient amounts of platelets for clinical usage. Within the evaluated procedures, platelet numbers and numbers of white blood cells differ significantly. The intra-individual results of platelet-rich plasma separations showed wide variations in platelet and cell numbers as well as levels of growth factors regardless of separation method.
Skill Sheets for Agricultural Mechanics.
ERIC Educational Resources Information Center
Iowa State Univ. of Science and Technology, Ames. Dept. of Agricultural Education.
This set of 33 skill sheets for agricultural mechanics was developed for use in high school and vocational school agricultural mechanics programs. Some sheets teach operational procedures while others are for simple projects. Each skill sheet covers a single topic and includes: (1) a diagram, (2) a step-by-step construction or operational…
Kawakubo, Kazumichi; Kawakami, Hiroshi; Kuwatani, Masaki; Kudo, Taiki; Abe, Yoko; Kawahata, Shuhei; Kubo, Kimitoshi; Kubota, Yoshimasa; Sakamoto, Naoya
2015-02-01
Bilateral self-expandable metallic stent (SEMS) placement for the management of unresectable malignant hilar biliary obstruction (UMHBO) is technically challenging to perform using the existing metallic stents with thick delivery systems. The recently developed 6-Fr delivery systems could facilitate a single-step simultaneous side-by-side placement through the accessory channel of the duodenoscope. The aim of this study was to evaluate the feasibility of this procedure. Between May and September 2013, 13 consecutive patients with UMHBO underwent a single-step simultaneous side-by-side placement of SEMS with the 6-Fr delivery system. The technical success rate, stent patency, and rate of complications were evaluated from the prospectively collected database. Technical success was achieved in 11 (84.6%, 95% confidence interval [CI]: 57.8-95.8) patients. The median procedure time was 25 min. Early and late complications were observed in 23% (one segmental cholangitis and two liver abscesses) and 15% (one segmental cholangitis and one cholecystitis) patients, respectively. Median dysfunction free patency was 263 days (95% CI: 37-263). Five patients (38%) experienced stent occlusion that was successfully managed by endoscopic stent placement. A single-step simultaneous side-by-side placement of SEMS with a 6-Fr delivery system was feasible for the management of UMHBO. © 2014 Japanese Society of Hepato-Biliary-Pancreatic Surgery.
One-step selection of Vaccinia virus-binding DNA aptamers by MonoLEX
Nitsche, Andreas; Kurth, Andreas; Dunkhorst, Anna; Pänke, Oliver; Sielaff, Hendrik; Junge, Wolfgang; Muth, Doreen; Scheller, Frieder; Stöcklein, Walter; Dahmen, Claudia; Pauli, Georg; Kage, Andreas
2007-01-01
Background As a new class of therapeutic and diagnostic reagents, more than fifteen years ago RNA and DNA aptamers were identified as binding molecules to numerous small compounds, proteins and rarely even to complete pathogen particles. Most aptamers were isolated from complex libraries of synthetic nucleic acids by a process termed SELEX based on several selection and amplification steps. Here we report the application of a new one-step selection method (MonoLEX) to acquire high-affinity DNA aptamers binding Vaccinia virus used as a model organism for complex target structures. Results The selection against complete Vaccinia virus particles resulted in a 64-base DNA aptamer specifically binding to orthopoxviruses as validated by dot blot analysis, Surface Plasmon Resonance, Fluorescence Correlation Spectroscopy and real-time PCR, following an aptamer blotting assay. The same oligonucleotide showed the ability to inhibit in vitro infection of Vaccinia virus and other orthopoxviruses in a concentration-dependent manner. Conclusion The MonoLEX method is a straightforward procedure as demonstrated here for the identification of a high-affinity DNA aptamer binding Vaccinia virus. MonoLEX comprises a single affinity chromatography step, followed by subsequent physical segmentation of the affinity resin and a single final PCR amplification step of bound aptamers. Therefore, this procedure improves the selection of high affinity aptamers by reducing the competition between aptamers of different affinities during the PCR step, indicating an advantage for the single-round MonoLEX method. PMID:17697378
Estimating Slope and Level Change in N = 1 Designs
ERIC Educational Resources Information Center
Solanas, Antonio; Manolov, Rumen; Onghena, Patrick
2010-01-01
The current study proposes a new procedure for separately estimating slope change and level change between two adjacent phases in single-case designs. The procedure eliminates baseline trend from the whole data series before assessing treatment effectiveness. The steps necessary to obtain the estimates are presented in detail, explained, and…
One-step purification of nisin A by immunoaffinity chromatography.
Suárez, A M; Azcona, J I; Rodríguez, J M; Sanz, B; Hernández, P E
1997-12-01
The lantibiotic nisin A was purified to homogeneity by a single-step immunoaffinity chromatography method. An immunoadsorption matrix was developed by direct binding of anti-nisin A monoclonal antibodies to N-hydroxysuccinimide-activated Sepharose. The purification procedure was rapid and reproducible and rendered much higher final yields of nisin than any other described method.
Sanjuán, Ana; Price, Cathy J.; Mancini, Laura; Josse, Goulven; Grogan, Alice; Yamamoto, Adam K.; Geva, Sharon; Leff, Alex P.; Yousry, Tarek A.; Seghier, Mohamed L.
2013-01-01
Brain tumors can have different shapes or locations, making their identification very challenging. In functional MRI, it is not unusual that patients have only one anatomical image due to time and financial constraints. Here, we provide a modified automatic lesion identification (ALI) procedure which enables brain tumor identification from single MR images. Our method rests on (A) a modified segmentation-normalization procedure with an explicit “extra prior” for the tumor and (B) an outlier detection procedure for abnormal voxel (i.e., tumor) classification. To minimize tissue misclassification, the segmentation-normalization procedure requires prior information of the tumor location and extent. We therefore propose that ALI is run iteratively so that the output of Step B is used as a patient-specific prior in Step A. We test this procedure on real T1-weighted images from 18 patients, and the results were validated in comparison to two independent observers' manual tracings. The automated procedure identified the tumors successfully with an excellent agreement with the manual segmentation (area under the ROC curve = 0.97 ± 0.03). The proposed procedure increases the flexibility and robustness of the ALI tool and will be particularly useful for lesion-behavior mapping studies, or when lesion identification and/or spatial normalization are problematic. PMID:24381535
Yamaguchi, Akemi; Matsuda, Kazuyuki; Sueki, Akane; Taira, Chiaki; Uehara, Masayuki; Saito, Yasunori; Honda, Takayuki
2015-08-25
Reverse transcription (RT)-nested polymerase chain reaction (PCR) is a time-consuming procedure because it has several handling steps and is associated with the risk of cross-contamination during each step. Therefore, a rapid and sensitive one-step RT-nested PCR was developed that could be performed in a single tube using a droplet-PCR machine. The K562 BCR-ABL mRNA-positive cell line as well as bone marrow aspirates from 5 patients with chronic myelogenous leukemia (CML) and 5 controls without CML were used. We evaluated one-step RT-nested PCR using the droplet-PCR machine. One-step RT-nested PCR performed in a single tube using the droplet-PCR machine enabled the detection of BCR-ABL mRNA within 40min, which was 10(3)-fold superior to conventional RT nested PCR using three steps in separate tubes. The sensitivity of the one-step RT-nested PCR was 0.001%, with sample reactivity comparable to that of the conventional assay. One-step RT-nested PCR was developed using the droplet-PCR machine, which enabled all reactions to be performed in a single tube accurately and rapidly and with high sensitivity. This one-step RT-nested PCR may be applicable to a wide spectrum of genetic tests in clinical laboratories. Copyright © 2015 Elsevier B.V. All rights reserved.
Morel, Sylvie; Landreau, Anne; Nguyen, Van Hung; Derbré, Séverine; Grellier, Philippe; Pape, Patrice Le; Pagniez, Fabrice; Litaudon, Marc; Richomme, Pascal
2012-01-01
The Derris genus is known to contain flavonoid derivatives, including prenylated flavanones and isoflavonoids such as rotenoids, which are generally associated with significant biological activity. To develop an efficient preparative isolation procedure for bioactive cajaflavanone. Fast centrifugal partition chromatography (FCPC) was optimised to purify cajaflavanone from Derris ferruginea stems in a single step as compared to fractionation from the cyclohexane extract by successive conventional solid-liquid chromatography procedures. The purification yield, purity, time and solvent consumption per procedure are described. The anti-fungal, anti-bacterial, anti-leishmanial, anti-plasmodial, anti-oxidant activities and the inhibition of advanced glycation end-products (AGEs) by cajaflavanone accumulation are described. FCPC enabled cajaflavanone purification in a single separation step, yielding sufficient quantities to perform in vitro biological screening. Interestingly, cajaflavanone had an inhibitory effect on the formation of AGEs, without displaying any in vitro anti-oxidant activity. A simple and efficient procedure, in comparison with other preparative methods, for bioactive cajaflavone purification has been developed using FCPC. Copyright © 2011 John Wiley & Sons, Ltd.
Nagano, Hanatsu; Levinger, Pazit; Downie, Calum; Hayes, Alan; Begg, Rezaul
2015-09-01
Falls during walking reflect susceptibility to balance loss and the individual's capacity to recover stability. Balance can be recovered using either one step or multiple steps but both responses are impaired with ageing. To investigate older adults' (n=15, 72.5±4.8 yrs) recovery step control a tether-release procedure was devised to induce unanticipated forward balance loss. Three-dimensional position-time data combined with foot-ground reaction forces were used to measure balance recovery. Dependent variables were; margin of stability (MoS) and available response time (ART) for spatial and temporal balance measures in the transverse and sagittal planes; lower limb joint angles and joint negative/positive work; and spatio-temporal gait parameters. Relative to multi-step responses, single-step recovery was more effective in maintaining balance, indicated by greater MoS and longer ART. MoS in the sagittal plane measure and ART in the transverse plane distinguished single step responses from multiple steps. When MoS and ART were negative (<0), balance was not secured and additional steps would be required to establish the new base of support for balance recovery. Single-step responses demonstrated greater step length and velocity and when the recovery foot landed, greater centre of mass downward velocity. Single-step strategies also showed greater ankle dorsiflexion, increased knee maximum flexion and more negative work at the ankle and knee. Collectively these findings suggest that single-step responses are more effective in forward balance recovery by directing falling momentum downward to be absorbed as lower limb eccentric work. Copyright © 2015 Elsevier B.V. All rights reserved.
One-step purification of nisin A by immunoaffinity chromatography.
Suárez, A M; Azcona, J I; Rodríguez, J M; Sanz, B; Hernández, P E
1997-01-01
The lantibiotic nisin A was purified to homogeneity by a single-step immunoaffinity chromatography method. An immunoadsorption matrix was developed by direct binding of anti-nisin A monoclonal antibodies to N-hydroxysuccinimide-activated Sepharose. The purification procedure was rapid and reproducible and rendered much higher final yields of nisin than any other described method. PMID:9406424
Adali, M Kemal; Uzun, Cem
2005-09-01
The aim of the present study is to evaluate the effect of swallowing type (dry versus wet) on the outcome of a nine-step inflation/deflation tympanometric Eustachian tube function (ETF) test in healthy adults. Fourteen normal healthy volunteers, between 19 and 28 years of age, were included in the study. The nine-step test was performed in two different test procedures: (1) test with dry swallows (dry test procedure) and (2) test with liquid swallows (wet test procedure). If the equilibration of middle-ear (ME) pressure was successful in all the steps of the nine-step test, ETF was considered 'Good'. Otherwise, the test was considered 'Poor', and the test was repeated at a second session. In the dry test procedure, ETF was 'Good' in 21 ears at the first session and in 24 ears after the second session (p > 0.05). However, in the wet test procedure, ETF was 'Good' in 13 ears at the first session and in 21 ears after the second session (p < 0.05). At the first session, ETF was 'Good' in 21 and 13 ears in the dry and wet test procedures, respectively. The difference was statistically significant (p < 0.05). However, after the second session, the overall number of ears with 'Good' tubal function was almost the same in both test procedures (24 ears at dry test procedures versus 21 ears at wet test procedures;p > 0.05). Dry swallowing seems to be more effective for the equilibration of ME pressure. Thus, a single-session dependent evaluation of ETF may be efficient for the dry test procedure of the nine-step test. Swallowing with water may be easier for subjects, but a repetition of the test at a second session may be necessary when the test result is 'Poor'.
Computerized procedures system
Lipner, Melvin H.; Mundy, Roger A.; Franusich, Michael D.
2010-10-12
An online data driven computerized procedures system that guides an operator through a complex process facility's operating procedures. The system monitors plant data, processes the data and then, based upon this processing, presents the status of the current procedure step and/or substep to the operator. The system supports multiple users and a single procedure definition supports several interface formats that can be tailored to the individual user. Layered security controls access privileges and revisions are version controlled. The procedures run on a server that is platform independent of the user workstations that the server interfaces with and the user interface supports diverse procedural views.
NASA Astrophysics Data System (ADS)
Gassara, H.; El Hajjaji, A.; Chaabane, M.
2017-07-01
This paper investigates the problem of observer-based control for two classes of polynomial fuzzy systems with time-varying delay. The first class concerns a special case where the polynomial matrices do not depend on the estimated state variables. The second one is the general case where the polynomial matrices could depend on unmeasurable system states that will be estimated. For the last case, two design procedures are proposed. The first one gives the polynomial fuzzy controller and observer gains in two steps. In the second procedure, the designed gains are obtained using a single-step approach to overcome the drawback of a two-step procedure. The obtained conditions are presented in terms of sum of squares (SOS) which can be solved via the SOSTOOLS and a semi-definite program solver. Illustrative examples show the validity and applicability of the proposed results.
Electronic Procedures for Medical Operations
NASA Technical Reports Server (NTRS)
2015-01-01
Electronic procedures are replacing text-based documents for recording the steps in performing medical operations aboard the International Space Station. S&K Aerospace, LLC, has developed a content-based electronic system-based on the Extensible Markup Language (XML) standard-that separates text from formatting standards and tags items contained in procedures so they can be recognized by other electronic systems. For example, to change a standard format, electronic procedures are changed in a single batch process, and the entire body of procedures will have the new format. Procedures can be quickly searched to determine which are affected by software and hardware changes. Similarly, procedures are easily shared with other electronic systems. The system also enables real-time data capture and automatic bookmarking of current procedure steps. In Phase II of the project, S&K Aerospace developed a Procedure Representation Language (PRL) and tools to support the creation and maintenance of electronic procedures for medical operations. The goal is to develop these tools in such a way that new advances can be inserted easily, leading to an eventual medical decision support system.
A New Gimmick for Assigning Absolute Configuration.
ERIC Educational Resources Information Center
Ayorinde, F. O.
1983-01-01
A five-step procedure is provided to help students in making the assignment absolute configuration less bothersome. Examples for both single (2-butanol) and multi-chiral carbon (3-chloro-2-butanol) molecules are included. (JN)
Effectively-truncated large-scale shell-model calculations and nuclei around 100Sn
NASA Astrophysics Data System (ADS)
Gargano, A.; Coraggio, L.; Itaco, N.
2017-09-01
This paper presents a short overview of a procedure we have recently introduced, dubbed the double-step truncation method, which is aimed to reduce the computational complexity of large-scale shell-model calculations. Within this procedure, one starts with a realistic shell-model Hamiltonian defined in a large model space, and then, by analyzing the effective single particle energies of this Hamiltonian as a function of the number of valence protons and/or neutrons, reduced model spaces are identified containing only the single-particle orbitals relevant to the description of the spectroscopic properties of a certain class of nuclei. As a final step, new effective shell-model Hamiltonians defined within the reduced model spaces are derived by way of a unitary transformation of the original large-scale Hamiltonian. A detailed account of this transformation is given and the merit of the double-step truncation method is illustrated by discussing few selected results for 96Mo, described as four protons and four neutrons outside 88Sr. Some new preliminary results for light odd-tin isotopes from A = 101 to 107 are also reported.
Ebigbo, Alanna; Probst, Andreas; Römmele, Christoph; Messmann, Helmut
2018-05-01
The endoscopic submucosal dissection (ESD) of cancerous and precancerous lesions in the gastrointestinal (GI) tract is an effective but difficult-to-learn procedure, especially for Western endoscopists. We developed a step-up training protocol and evaluated its outcome on a single endoscopist using specific performance measures. The training protocol included a 12-month period of 50 observational and supervised ESD cases as well as 24 animal procedures. After completion of the protocol, ESD competency was evaluated in the first 30 independent ESD cases. Majority of lesions were located in the stomach and rectum. Performance measures included R0-resection rate, complication rate and resection speed. R0 resection rate was 93 %, complication rate was 7 % and median resection speed was 6,77 cm 2 /h. 1 case of delayed perforation with subsequent hemicolectomy occurred in the descending colon. The ESD step-up training protocol used in this study on a single endoscopist showed excellent outcomes for lesions in the rectum and stomach. However, ESD training in the upper colon remains a challenge.
Vectorized Rebinning Algorithm for Fast Data Down-Sampling
NASA Technical Reports Server (NTRS)
Dean, Bruce; Aronstein, David; Smith, Jeffrey
2013-01-01
A vectorized rebinning (down-sampling) algorithm, applicable to N-dimensional data sets, has been developed that offers a significant reduction in computer run time when compared to conventional rebinning algorithms. For clarity, a two-dimensional version of the algorithm is discussed to illustrate some specific details of the algorithm content, and using the language of image processing, 2D data will be referred to as "images," and each value in an image as a "pixel." The new approach is fully vectorized, i.e., the down-sampling procedure is done as a single step over all image rows, and then as a single step over all image columns. Data rebinning (or down-sampling) is a procedure that uses a discretely sampled N-dimensional data set to create a representation of the same data, but with fewer discrete samples. Such data down-sampling is fundamental to digital signal processing, e.g., for data compression applications.
NASA Astrophysics Data System (ADS)
Shenoy, U. Sandhya; Shetty, A. Nityananda
2018-03-01
Enhancement of thermal properties of conventional heat transfer fluids has become one of the important technical challenges. Since nanofluids offer a promising help in this regard, development of simpler and hassle free routes for their synthesis is of utmost importance. Synthesis of nanofluids using a hassle free route with greener chemicals has been reported. The single-step chemical approach reported here overcomes the drawbacks of the two-step procedures in the synthesis of nanofluids. The resulting Newtonian nanofluids prepared contained cuboctahedral particles of cuprous oxide and exhibited a thermal conductivity of 2.852 W·m-1·K-1. Polyvinylpyrrolidone (PVP) used during the synthesis acted as a stabilizing agent rendering the nanofluid a stability of 9 weeks.
Prabhavathi Devi, B L A; Vijai Kumar Reddy, T; Vijaya Lakshmi, K; Prasad, R B N
2014-02-01
Simultaneous esterification and transesterification method is employed for the preparation of biodiesel from 7.5% free fatty acid (FFA) containing karanja (Pongamia glabra) oil using water resistant and reusable carbon-based solid acid catalyst derived from glycerol in a single step. The optimum reaction parameters for obtaining biodiesel in >99% yield by simultaneous esterification and transesterification are: methanol (1:45 mole ratio of oil), catalyst 20wt.% of oil, temperature 160°C and reaction time of 4h. After the reaction, the catalyst was easily recovered by filtration and reused for five times with out any deactivation under optimized conditions. This single-step process could be a potential route for biodiesel production from high FFA containing oils by simplifying the procedure and reducing costs and effluent generation. Copyright © 2013 Elsevier Ltd. All rights reserved.
Grey-box state-space identification of nonlinear mechanical vibrations
NASA Astrophysics Data System (ADS)
Noël, J. P.; Schoukens, J.
2018-05-01
The present paper deals with the identification of nonlinear mechanical vibrations. A grey-box, or semi-physical, nonlinear state-space representation is introduced, expressing the nonlinear basis functions using a limited number of measured output variables. This representation assumes that the observed nonlinearities are localised in physical space, which is a generic case in mechanics. A two-step identification procedure is derived for the grey-box model parameters, integrating nonlinear subspace initialisation and weighted least-squares optimisation. The complete procedure is applied to an electrical circuit mimicking the behaviour of a single-input, single-output (SISO) nonlinear mechanical system and to a single-input, multiple-output (SIMO) geometrically nonlinear beam structure.
Kubová, Jana; Matús, Peter; Bujdos, Marek; Hagarová, Ingrid; Medved', Ján
2008-05-30
The prediction of soil metal phytoavailability using the chemical extractions is a conventional approach routinely used in soil testing. The adequacy of such soil tests for this purpose is commonly assessed through a comparison of extraction results with metal contents in relevant plants. In this work, the fractions of selected risk metals (Al, As, Cd, Cu, Fe, Mn, Ni, Pb, Zn) that can be taken up by various plants were obtained by optimized BCR (Community Bureau of Reference) three-step sequential extraction procedure (SEP) and by single 0.5 mol L(-1) HCl extraction. These procedures were validated using five soil and sediment reference materials (SRM 2710, SRM 2711, CRM 483, CRM 701, SRM RTH 912) and applied to significantly different acidified soils for the fractionation of studied metals. The new indicative values of Al, Cd, Cu, Fe, Mn, P, Pb and Zn fractional concentrations for these reference materials were obtained by the dilute HCl single extraction. The influence of various soil genesis, content of essential elements (Ca, Mg, K, P) and different anthropogenic sources of acidification on extraction yields of individual risk metal fractions was investigated. The concentrations of studied elements were determined by atomic spectrometry methods (flame, graphite furnace and hydride generation atomic absorption spectrometry and inductively coupled plasma optical emission spectrometry). It can be concluded that the data of extraction yields from first BCR SEP acid extractable step and soil-plant transfer coefficients can be applied to the prediction of qualitative mobility of selected risk metals in different soil systems.
Precision-engineering the Pseudomonas aeruginosa genome with two-step allelic exchange
Hmelo, Laura R.; Borlee, Bradley R.; Almblad, Henrik; Love, Michelle E.; Randall, Trevor E.; Tseng, Boo Shan; Lin, Chuyang; Irie, Yasuhiko; Storek, Kelly M.; Yang, Jaeun Jane; Siehnel, Richard J.; Howell, P. Lynne; Singh, Pradeep K.; Tolker-Nielsen, Tim; Parsek, Matthew R.; Schweizer, Herbert P.; Harrison, Joe J.
2016-01-01
Allelic exchange is an efficient method of bacterial genome engineering. This protocol describes the use of this technique to make gene knockouts and knockins, as well as single nucleotide insertions, deletions and substitutions in Pseudomonas aeruginosa. Unlike other approaches to allelic exchange, this protocol does not require heterologous recombinases to insert or excise selective markers from the target chromosome. Rather, positive and negative selection are enabled solely by suicide vector-encoded functions and host cell proteins. Here, mutant alleles, which are flanked by regions of homology to the recipient chromosome, are synthesized in vitro and then cloned into allelic exchange vectors using standard procedures. These suicide vectors are then introduced into recipient cells by conjugation. Homologous recombination then results in antibiotic resistant single-crossover mutants in which the plasmid has integrated site-specifically into the chromosome. Subsequently, unmarked double-crossover mutants are isolated directly using sucrose-mediated counter-selection. This two-step process yields seamless mutations that are precise to a single base pair of DNA. The entire procedure requires ~2 weeks. PMID:26492139
Bekkers, Joris E J; Tsuchida, Anika I; van Rijen, Mattie H P; Vonk, Lucienne A; Dhert, Wouter J A; Creemers, Laura B; Saris, Daniel B F
2013-09-01
Autologous chondrocyte implantation (ACI) is traditionally a 2-step procedure used to repair focal articular cartilage lesions. With use of a combination of chondrons (chondrocytes in their own territorial matrix) and mesenchymal stromal cells (MSCs), ACI could be innovated and performed in a single step, as sufficient cells would be available to fill the defect within a 1-step surgical procedure. Chondrons have been shown to have higher regenerative capacities than chondrocytes without such a pericellular matrix. To evaluate cartilage formation by a combination of chondrons and MSCs in vitro and in both small and large animal models. Controlled laboratory study. Chondrons and MSCs were cultured at different ratios in vitro containing 0%, 5%, 10%, 20%, 50%, or 100% chondrons (n = 3); embedded in injectable fibrin glue (Beriplast); and implanted subcutaneously in nude mice (n = 10; ratios of 0%, 5%, 10%, and 20% chondrons). Also, in a 1-step procedure, a combination of chondrons and MSCs was implanted in a freshly created focal articular cartilage lesion (10% chondrons) in goats (n = 8) and compared with microfracture. The effect of both treatments, after 6-month follow-up, was evaluated using biochemical glycosaminoglycan (GAG) and GAG/DNA analysis and scored using validated scoring systems for macroscopic and microscopic defect repairs. The addition of MSCs to chondron cultures enhanced cartilage-specific matrix production as reflected by a higher GAG production (P < .03), both in absolute levels and normalized to DNA content, compared with chondrocyte and 100% chondron cultures. Similar results were observed after 4 weeks of subcutaneous implantation in nude mice. Treatment of freshly created cartilage defects in goats using a combination of chondrons and MSCs in Beriplast resulted in better microscopic, macroscopic, and biochemical cartilage regeneration (P ≤ .02) compared with microfracture treatment. The combination of chondrons and MSCs increased cartilage matrix formation, and this combination of cells was safely applied in a goat model for focal cartilage lesions, outperforming microfracture. This study describes the bench-to-preclinical development of a new cell-based regenerative treatment for focal articular cartilage defects that outperforms microfracture in goats. In addition, it is a single-step procedure, thereby making the expensive cell expansion and reimplantation of dedifferentiated cells, as in ACI, redundant.
Surface Passivation for Single-molecule Protein Studies
Chandradoss, Stanley D.; Haagsma, Anna C.; Lee, Young Kwang; Hwang, Jae-Ho; Nam, Jwa-Min; Joo, Chirlmin
2014-01-01
Single-molecule fluorescence spectroscopy has proven to be instrumental in understanding a wide range of biological phenomena at the nanoscale. Important examples of what this technique can yield to biological sciences are the mechanistic insights on protein-protein and protein-nucleic acid interactions. When interactions of proteins are probed at the single-molecule level, the proteins or their substrates are often immobilized on a glass surface, which allows for a long-term observation. This immobilization scheme may introduce unwanted surface artifacts. Therefore, it is essential to passivate the glass surface to make it inert. Surface coating using polyethylene glycol (PEG) stands out for its high performance in preventing proteins from non-specifically interacting with a glass surface. However, the polymer coating procedure is difficult, due to the complication arising from a series of surface treatments and the stringent requirement that a surface needs to be free of any fluorescent molecules at the end of the procedure. Here, we provide a robust protocol with step-by-step instructions. It covers surface cleaning including piranha etching, surface functionalization with amine groups, and finally PEG coating. To obtain a high density of a PEG layer, we introduce a new strategy of treating the surface with PEG molecules over two rounds, which remarkably improves the quality of passivation. We provide representative results as well as practical advice for each critical step so that anyone can achieve the high quality surface passivation. PMID:24797261
ERIC Educational Resources Information Center
Knight, G. William; And Others
1994-01-01
The first step in engineering the instruction of dental psychomotor skills, task analysis, is explained. A chart details the procedural, cognitive, desired-criteria, and desired-performance analysis of a single task, occlusal preparation for amalgam restoration with carious lesion. (MSE)
Continuous-Flow Synthesis of N-Succinimidyl 4-[18F]fluorobenzoate Using a Single Microfluidic Chip
Kimura, Hiroyuki; Tomatsu, Kenji; Saiki, Hidekazu; Arimitsu, Kenji; Ono, Masahiro; Kawashima, Hidekazu; Iwata, Ren; Nakanishi, Hiroaki; Ozeki, Eiichi; Kuge, Yuji; Saji, Hideo
2016-01-01
In the field of positron emission tomography (PET) radiochemistry, compact microreactors provide reliable and reproducible synthesis methods that reduce the use of expensive precursors for radiolabeling and make effective use of the limited space in a hot cell. To develop more compact microreactors for radiosynthesis of 18F-labeled compounds required for the multistep procedure, we attempted radiosynthesis of N-succinimidyl 4-[18F]fluorobenzoate ([18F]SFB) via a three-step procedure using a microreactor. We examined individual steps for [18F]SFB using a batch reactor and microreactor and developed a new continuous-flow synthetic method with a single microfluidic chip to achieve rapid and efficient radiosynthesis of [18F]SFB. In the synthesis of [18F]SFB using this continuous-flow method, the three-step reaction was successfully completed within 6.5 min and the radiochemical yield was 64 ± 2% (n = 5). In addition, it was shown that the quality of [18F]SFB synthesized on this method was equal to that synthesized by conventional methods using a batch reactor in the radiolabeling of bovine serum albumin with [18F]SFB. PMID:27410684
Multiple intensity distributions from a single optical element
NASA Astrophysics Data System (ADS)
Berens, Michael; Bruneton, Adrien; Bäuerle, Axel; Traub, Martin; Wester, Rolf; Stollenwerk, Jochen; Loosen, Peter
2013-09-01
We report on an extension of the previously published two-step freeform optics tailoring algorithm using a Monge-Kantorovich mass transportation framework. The algorithm's ability to design multiple freeform surfaces allows for the inclusion of multiple distinct light paths and hence the implementation of multiple lighting functions in a single optical element. We demonstrate the procedure in the context of automotive lighting, in which a fog lamp and a daytime running lamp are integrated in a single optical element illuminated by two distinct groups of LEDs.
Laser-induced thermal ablation of cancerous cell organelles.
Letfullin, Renat R; Szatkowski, Scott A
2017-07-01
By exploiting the physical changes experienced by cancerous organelles, we investigate the feasibility of destroying cancerous cells by single and multipulse modes of laser heating. Our procedure consists of two primary steps: determining the normal and cancerous organelles optical properties and simulating the heating of all of the major organelles in the cell to find the treatment modes for the laser ablation of cancerous organelles without harming healthy cells. Our simulations show that the cancerous nucleus can be selectively heated to damaging temperatures, making this nucleus a feasible therapeutic particle and removing the need for nanoparticle injection. Because of the removal of this extra step, the procedure we propose is simpler and safer for the patient.
Single-cell transcriptome conservation in cryopreserved cells and tissues.
Guillaumet-Adkins, Amy; Rodríguez-Esteban, Gustavo; Mereu, Elisabetta; Mendez-Lago, Maria; Jaitin, Diego A; Villanueva, Alberto; Vidal, August; Martinez-Marti, Alex; Felip, Enriqueta; Vivancos, Ana; Keren-Shaul, Hadas; Heath, Simon; Gut, Marta; Amit, Ido; Gut, Ivo; Heyn, Holger
2017-03-01
A variety of single-cell RNA preparation procedures have been described. So far, protocols require fresh material, which hinders complex study designs. We describe a sample preservation method that maintains transcripts in viable single cells, allowing one to disconnect time and place of sampling from subsequent processing steps. We sequence single-cell transcriptomes from >1000 fresh and cryopreserved cells using 3'-end and full-length RNA preparation methods. Our results confirm that the conservation process did not alter transcriptional profiles. This substantially broadens the scope of applications in single-cell transcriptomics and could lead to a paradigm shift in future study designs.
Shackelford, Stacy; Garofalo, Evan; Shalin, Valerie; Pugh, Kristy; Chen, Hegang; Pasley, Jason; Sarani, Babak; Henry, Sharon; Bowyer, Mark; Mackenzie, Colin F
2015-07-01
Maintaining trauma-specific surgical skills is an ongoing challenge for surgical training programs. An objective assessment of surgical skills is needed. We hypothesized that a validated surgical performance assessment tool could detect differences following a training intervention. We developed surgical performance assessment metrics based on discussion with expert trauma surgeons, video review of 10 experts and 10 novice surgeons performing three vascular exposure procedures and lower extremity fasciotomy on cadavers, and validated the metrics with interrater reliability testing by five reviewers blinded to level of expertise and a consensus conference. We tested these performance metrics in 12 surgical residents (Year 3-7) before and 2 weeks after vascular exposure skills training in the Advanced Surgical Skills for Exposure in Trauma (ASSET) course. Performance was assessed in three areas as follows: knowledge (anatomic, management), procedure steps, and technical skills. Time to completion of procedures was recorded, and these metrics were combined into a single performance score, the Trauma Readiness Index (TRI). Wilcoxon matched-pairs signed-ranks test compared pretraining/posttraining effects. Mean time to complete procedures decreased by 4.3 minutes (from 13.4 minutes to 9.1 minutes). The performance component most improved by the 1-day skills training was procedure steps, completion of which increased by 21%. Technical skill scores improved by 12%. Overall knowledge improved by 3%, with 18% improvement in anatomic knowledge. TRI increased significantly from 50% to 64% with ASSET training. Interrater reliability of the surgical performance assessment metrics was validated with single intraclass correlation coefficient of 0.7 to 0.98. A trauma-relevant surgical performance assessment detected improvements in specific procedure steps and anatomic knowledge taught during a 1-day course, quantified by the TRI. ASSET training reduced time to complete vascular control by one third. Future applications include assessing specific skills in a larger surgeon cohort, assessing military surgical readiness, and quantifying skill degradation with time since training.
Morisse Pradier, H; Sénéchal, A; Philit, F; Tronc, F; Maury, J-M; Grima, R; Flamens, C; Paulus, S; Neidecker, J; Mornex, J-F
2016-02-01
Lung transplantation (LT) is now considered as an excellent treatment option for selected patients with end-stage pulmonary diseases, such as COPD, cystic fibrosis, idiopathic pulmonary fibrosis, and pulmonary arterial hypertension. The 2 goals of LT are to provide a survival benefit and to improve quality of life. The 3-step decision process leading to LT is discussed in this review. The first step is the selection of candidates, which requires a careful examination in order to check absolute and relative contraindications. The second step is the timing of listing for LT; it requires the knowledge of disease-specific prognostic factors available in international guidelines, and discussed in this paper. The third step is the choice of procedure: indications of heart-lung, single-lung, and bilateral-lung transplantation are described. In conclusion, this document provides guidelines to help pulmonologists in the referral and selection processes of candidates for transplantation in order to optimize the outcome of LT. Copyright © 2014 Elsevier Masson SAS. All rights reserved.
Ali, Ghafar; Ahmad, Maqsood; Akhter, Javed Iqbal; Maqbool, Muhammad; Cho, Sung Oh
2010-08-01
A simple approach for the growth of long-range highly ordered nanoporous anodic alumina film in H(2)SO(4) electrolyte through a single step anodization without any additional pre-anodizing procedure is reported. Free-standing porous anodic alumina film of 180 microm thickness with through hole morphology was obtained. A simple and single step process was used for the detachment of alumina from aluminum substrate. The effect of anodizing conditions, such as anodizing voltage and time on the pore diameter and pore ordering is discussed. The metal/oxide and oxide/electrolyte interfaces were examined by high resolution scanning transmission electron microscope. The arrangement of pores on metal/oxide interface was well ordered with smaller diameters than that of the oxide/electrolyte interface. The inter-pore distance was larger in metal/oxide interface as compared to the oxide/electrolyte interface. The size of the ordered domain was found to depend strongly upon anodizing voltage and time. (c) 2010 Elsevier Ltd. All rights reserved.
Tran, Ngoc Han; Hu, Jiangyong; Ong, Say Leong
2013-09-15
A high-throughput method for the simultaneous determination of 24 pharmaceuticals and personal care products (PPCPs), endocrine disrupting chemicals (EDCs) and artificial sweeteners (ASs) was developed. The method was based on a single-step solid phase extraction (SPE) coupled with high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) and isotope dilution. In this study, a single-step SPE procedure was optimized for simultaneous extraction of all target analytes. Good recoveries (≥ 70%) were observed for all target analytes when extraction was performed using Chromabond(®) HR-X (500 mg, 6 mL) cartridges under acidic condition (pH 2). HPLC-MS/MS parameters were optimized for the simultaneous analysis of 24 PPCPs, EDCs and ASs in a single injection. Quantification was performed by using 13 isotopically labeled internal standards (ILIS), which allows correcting efficiently the loss of the analytes during SPE procedure, matrix effects during HPLC-MS/MS and fluctuation in MS/MS signal intensity due to instrument. Method quantification limit (MQL) for most of the target analytes was below 10 ng/L in all water samples. The method was successfully applied for the simultaneous determination of PPCPs, EDCs and ASs in raw wastewater, surface water and groundwater samples collected in a local catchment area in Singapore. In conclusion, the developed method provided a valuable tool for investigating the occurrence, behavior, transport, and the fate of PPCPs, EDCs and ASs in the aquatic environment. Copyright © 2013 Elsevier B.V. All rights reserved.
Direct optical detection of protein-ligand interactions.
Gesellchen, Frank; Zimmermann, Bastian; Herberg, Friedrich W
2005-01-01
Direct optical detection provides an excellent means to investigate interactions of molecules in biological systems. The dynamic equilibria inherent to these systems can be described in greater detail by recording the kinetics of a biomolecular interaction. Optical biosensors allow direct detection of interaction patterns without the need for labeling. An overview covering several commercially available biosensors is given, with a focus on instruments based on surface plasmon resonance (SPR) and reflectometric interference spectroscopy (RIFS). Potential assay formats and experimental design, appropriate controls, and calibration procedures, especially when handling low molecular weight substances, are discussed. The single steps of an interaction analysis combined with practical tips for evaluation, data processing, and interpretation of kinetic data are described in detail. In a practical example, a step-by-step procedure for the analysis of a low molecular weight compound interaction with serum protein, determined on a commercial SPR sensor, is presented.
Tetraethylene glycol promoted two-step, one-pot rapid synthesis of indole-3-[1- 11C]acetic acid
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, Sojeong; Qu, Wenchao; Alexoff, David L.
2014-12-12
An operationally friendly, two-step, one-pot process has been developed for the rapid synthesis of carbon-11 labeled indole-3-acetic acid ([ 11]IAA or [ 11]auxin). By replacing an aprotic polar solvent with tetraethylene glycol, nucleophilic [ 11]cyanation and alkaline hydrolysis reactions were performed consecutively in a single pot without a time-consuming intermediate purification step. The entire production time for this updated procedure is 55 min, which dramatically simplifies the entire synthesis and reduces the starting radioactivity required for a whole plant imaging study.
GWAS with longitudinal phenotypes: performance of approximate procedures
Sikorska, Karolina; Montazeri, Nahid Mostafavi; Uitterlinden, André; Rivadeneira, Fernando; Eilers, Paul HC; Lesaffre, Emmanuel
2015-01-01
Analysis of genome-wide association studies with longitudinal data using standard procedures, such as linear mixed model (LMM) fitting, leads to discouragingly long computation times. There is a need to speed up the computations significantly. In our previous work (Sikorska et al: Fast linear mixed model computations for genome-wide association studies with longitudinal data. Stat Med 2012; 32.1: 165–180), we proposed the conditional two-step (CTS) approach as a fast method providing an approximation to the P-value for the longitudinal single-nucleotide polymorphism (SNP) effect. In the first step a reduced conditional LMM is fit, omitting all the SNP terms. In the second step, the estimated random slopes are regressed on SNPs. The CTS has been applied to the bone mineral density data from the Rotterdam Study and proved to work very well even in unbalanced situations. In another article (Sikorska et al: GWAS on your notebook: fast semi-parallel linear and logistic regression for genome-wide association studies. BMC Bioinformatics 2013; 14: 166), we suggested semi-parallel computations, greatly speeding up fitting many linear regressions. Combining CTS with fast linear regression reduces the computation time from several weeks to a few minutes on a single computer. Here, we explore further the properties of the CTS both analytically and by simulations. We investigate the performance of our proposal in comparison with a related but different approach, the two-step procedure. It is analytically shown that for the balanced case, under mild assumptions, the P-value provided by the CTS is the same as from the LMM. For unbalanced data and in realistic situations, simulations show that the CTS method does not inflate the type I error rate and implies only a minimal loss of power. PMID:25712081
Effect of saliva decontamination procedures on shear bond strength of a one-step adhesive system.
Ülker, E; Bilgin, S; Kahvecioğlu, F; Erkan, A I
2017-09-01
To evaluate the effect of different saliva decontamination procedures on the shear bond strength of a one-step universal adhesive system (Single Bond™ Universal Adhesive, 3M ESPE, St. Paul, MN, USA). The occlusal surfaces of 75 human third molars were ground to expose dentin. The teeth were divided into the following groups: Group 1 (control group): Single Bond™ Universal Adhesive was applied to the prepared tooth according to the manufacturer's recommendations and light cured; no contamination procedure was performed. Group 2: Bonding, light curing, saliva contamination, and dry. Group 3: Bonding, light curing, saliva contamination, rinse, and dry. Group 4: After the procedure performed in Group 2, reapplication of bonding. Group 5: After the procedure performed in Group 3, reapplication of bonding. Then, composite resins were applied with cylindrical-shaped plastic matrixes and light cured. For shear bond testing, a notch-shaped force transducer apparatus was applied to each specimen at the interface between the tooth and composite until failure occurred. The data were statistically analyzed using one-way ANOVA. One-way ANOVA revealed significant differences in shear bond strength between the control group and experimental Groups 2 and 4 (P < 0.05). No significant difference was found for experimental Groups 3 and 5 when compared to the control group (P > 0.05). The present in vitro study showed that water rinsing is necessary if cured adhesive resin is contaminated with saliva to ensure adequate bond strength.
Gimmon, Yoav; Jacob, Grinshpon; Lenoble-Hoskovec, Constanze; Büla, Christophe; Melzer, Itshak
2013-01-01
Decline in gait stability has been associated with increased fall risk in older adults. Reliable and clinically feasible methods of gait instability assessment are needed. This study evaluated the relative and absolute reliability and concurrent validity of the testing procedure of the clinical version of the Narrow Path Walking Test (NPWT) under single task (ST) and dual task (DT) conditions. Thirty independent community-dwelling older adults (65-87 years) were tested twice. Participants were instructed to walk within the 6-m narrow path without stepping out. Trial time, number of steps, trial velocity, number of step errors, and number of cognitive task errors were determined. Intraclass correlation coefficients (ICCs) were calculated as indices of agreement, and a graphic approach called "mountain plot" was applied to help interpret the direction and magnitude of disagreements between testing procedures. Smallest detectable change and smallest real difference (SRD) were computed to determine clinically relevant improvement at group and individual levels, respectively. Concurrent validity was assessed using Performance Oriented Mobility Assessment Tool (POMA) and the Short Physical Performance Battery (SPPB). Test-retest agreement (ICC1,2) varied from 0.77 to 0.92 in ST and from 0.78 to 0.92 in DT conditions, with no apparent systematic differences between testing procedures demonstrated by the mountain plot graphs. Smallest detectable change and smallest real change were small for motor task performance and larger for cognitive errors. Significant correlations were observed for trial velocity and trial time with POMA and SPPB. The present results indicate that the NPWT testing procedure is highly reliable and reproducible. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Straubinger, Rainer; Beyer, Andreas; Volz, Kerstin
2016-06-01
A reproducible way to transfer a single crystalline sample into a gas environmental cell holder for in situ transmission electron microscopic (TEM) analysis is shown in this study. As in situ holders have only single-tilt capability, it is necessary to prepare the sample precisely along a specific zone axis. This can be achieved by a very accurate focused ion beam lift-out preparation. We show a step-by-step procedure to prepare the sample and transfer it into the gas environmental cell. The sample material is a GaP/Ga(NAsP)/GaP multi-quantum well structure on Si. Scanning TEM observations prove that it is possible to achieve atomic resolution at very high temperatures in a nitrogen environment of 100,000 Pa.
Puppulin, Leonardo; Zhu, Wenliang; Sugano, Nobuhiko
2014-01-01
Three types of commercially available ultra-high molecular weight polyethylene (UHMWPE) acetabular cups currently used in total hip arthroplasty have been studied by means of Raman micro-spectroscopy to unfold the microstructural modification induced by the oxidative degradation after accelerated aging with and without lipid absorption. The three investigated materials were produced by three different manufacturing procedures, as follows: irradiation followed by remelting, one-step irradiation followed by annealing, 3-step irradiation and annealing. Clear microstructural differences were observed in terms of phase contents (i.e. amorphous, crystalline and intermediate phase fraction). The three-step annealed material showed the highest crystallinity fraction in the bulk, while the remelted polyethylene is clearly characterized by the lowest content of crystalline phase and the highest content of amorphous phase. After accelerated aging either with or without lipids, the amount of amorphous phase decreased in all the samples as a consequence of the oxidation-induced recrystallization. The most remarkable variations of phase contents were detected in the remelted and in the single-step annealed materials. The presence of lipids triggered oxidative degradation especially in the remelted polyethylene. Such experimental evidence might be explained by the highest amount of amorphous phase in which lipids can be absorbed prior to accelerated aging. The results of these spectroscopic characterizations help to rationalize the complex effect of different irradiation and post-irradiation treatments on the UHMWPE microstructure and gives useful information on how significantly any single step of the manufacturing procedures might affect the oxidative degradation of the polymer. PMID:25179830
Rajapandian, Subbiah; Bhushan, Chittawadagi; Sabnis, Sandeep C.; Jain, Manish; Raj, Palanivelu Praveen; Parathasarthi, Ramakrishnan; Senthilnathan, Palanisamy; Palanivelu, Chinnusamy
2018-01-01
Background: The popularity of single-incision procedures is on the rise as wound cosmesis is increasingly being seen as an important body image-related outcome. In this study, we assess the potential benefits of single-incision multiport laparoscopic totally extra-peritoneal (S-TEP) without using specialised ports or instruments and compare the same with the conventional laparoscopic TEP (C-TEP) surgery in terms of operative time, post-operative pain, complications, cost and cosmesis. Materials and Methods: This is a prospective case-matched study of the patients undergoing S-TEP versus C-TEP from June 2014 to December 2015. Results: Each group had 36 patients. The two groups were comparable in the clinical characteristics. The mean duration of surgery for a unilateral hernia in C-TEP and S-TEP was 45.13 ± 10.58 min and 72.63 ± 15.23 min, respectively. The mean visual analogue scale (VAS) score for pain was significantly higher in S-TEP group at post-operative day (POD) 0 and 1. However, at POD 7, there was no significant difference between the groups. At 1st and 6-week post-surgery, the cosmetic results were significantly better in S-TEP group as compared to C-TEP, however, at 6 months, the scar was highly acceptable in both treatment groups. Conclusion: S-TEP, using conventional laparoscopic instruments, is safe and feasible even in resource challenged setting. However, there is a need to review the indications and advantages of single-incision laparoscopic surgery, as no difference in cosmetic outcome by VAS score in S-TEP versus conventional laparoscopic arm seen by the end of 1 month. PMID:28695883
NASA Astrophysics Data System (ADS)
Regonda, Satish Kumar; Seo, Dong-Jun; Lawrence, Bill; Brown, James D.; Demargne, Julie
2013-08-01
We present a statistical procedure for generating short-term ensemble streamflow forecasts from single-valued, or deterministic, streamflow forecasts produced operationally by the U.S. National Weather Service (NWS) River Forecast Centers (RFCs). The resulting ensemble streamflow forecast provides an estimate of the predictive uncertainty associated with the single-valued forecast to support risk-based decision making by the forecasters and by the users of the forecast products, such as emergency managers. Forced by single-valued quantitative precipitation and temperature forecasts (QPF, QTF), the single-valued streamflow forecasts are produced at a 6-h time step nominally out to 5 days into the future. The single-valued streamflow forecasts reflect various run-time modifications, or "manual data assimilation", applied by the human forecasters in an attempt to reduce error from various sources in the end-to-end forecast process. The proposed procedure generates ensemble traces of streamflow from a parsimonious approximation of the conditional multivariate probability distribution of future streamflow given the single-valued streamflow forecast, QPF, and the most recent streamflow observation. For parameter estimation and evaluation, we used a multiyear archive of the single-valued river stage forecast produced operationally by the NWS Arkansas-Red River Basin River Forecast Center (ABRFC) in Tulsa, Oklahoma. As a by-product of parameter estimation, the procedure provides a categorical assessment of the effective lead time of the operational hydrologic forecasts for different QPF and forecast flow conditions. To evaluate the procedure, we carried out hindcasting experiments in dependent and cross-validation modes. The results indicate that the short-term streamflow ensemble hindcasts generated from the procedure are generally reliable within the effective lead time of the single-valued forecasts and well capture the skill of the single-valued forecasts. For smaller basins, however, the effective lead time is significantly reduced by short basin memory and reduced skill in the single-valued QPF.
Shen, Aijin; Wei, Jie; Yan, Jingyu; Jin, Gaowa; Ding, Junjie; Yang, Bingcheng; Guo, Zhimou; Zhang, Feifang; Liang, Xinmiao
2017-03-01
An orthogonal two-dimensional solid-phase extraction strategy was established for the selective enrichment of three aminoglycosides including spectinomycin, streptomycin, and dihydrostreptomycin in milk. A reversed-phase liquid chromatography material (C 18 ) and a weak cation-exchange material (TGA) were integrated in a single solid-phase extraction cartridge. The feasibility of two-dimensional clean-up procedure that experienced two-step adsorption, two-step rinsing, and two-step elution was systematically investigated. Based on the orthogonality of reversed-phase and weak cation-exchange procedures, the two-dimensional solid-phase extraction strategy could minimize the interference from the hydrophobic matrix existing in traditional reversed-phase solid-phase extraction. In addition, high ionic strength in the extracts could be effectively removed before the second dimension of weak cation-exchange solid-phase extraction. Combined with liquid chromatography and tandem mass spectrometry, the optimized procedure was validated according to the European Union Commission directive 2002/657/EC. A good performance was achieved in terms of linearity, recovery, precision, decision limit, and detection capability in milk. Finally, the optimized two-dimensional clean-up procedure incorporated with liquid chromatography and tandem mass spectrometry was successfully applied to the rapid monitoring of aminoglycoside residues in milk. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Purification Procedures for Single-Wall Carbon Nanotubes
NASA Technical Reports Server (NTRS)
Gorelik, Olga P.; Nikolaev, Pavel; Arepalli, Sivaram
2001-01-01
This report summarizes the comparison of a variety of procedures used to purify carbon nanotubes. Carbon nanotube material is produced by the arc process and laser oven process. Most of the procedures are tested using laser-grown, single-wall nanotube (SWNT) material. The material is characterized at each step of the purification procedures by using different techniques including scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDS), transmission electron microscopy (TEM), Raman, X-ray diffractometry (XRD), thermogravimetric analysis (TGA), nuclear magnetic resonance (NMR), and high-performance liquid chromatography (HPLC). The identified impurities are amorphous and graphitic carbon, catalyst particle aggregates, fullerenes, and hydrocarbons. Solvent extraction and low-temperature annealing are used to reduce the amount of volatile hydrocarbons and dissolve fullerenes. Metal catalysts and amorphous as well as graphitic carbon are oxidized by reflux in acids including HCl, HNO3 and HF and other oxidizers such as H2O2. High-temperature annealing in vacuum and in inert atmosphere helps to improve the quality of SWNTs by increasing crystallinity and reducing intercalation.
Overduin, Christiaan G; Heidkamp, Jan; Rothgang, Eva; Barentsz, Jelle O; de Lange, Frank; Fütterer, Jurgen J
2018-05-22
To assess the feasibility of adding a tablet device inside the scanner room to assist needle-guide alignment during magnetic resonance (MR)-guided transrectal prostate biopsy. Twenty patients with one cancer-suspicious region (CSR) with PI-RADS score ≥ 4 on diagnostic multiparametric MRI were prospectively enrolled. Two orthogonal scan planes of an MR fluoroscopy sequence (~3 images/s) were aligned to the CSR and needle-guide pivoting point. Targeting was achieved by manipulating the needle-guide under MR fluoroscopy feedback on the in-room tablet device. Technical feasibility and targeting success were assessed. Complications and biopsy procedure times were also recorded. Needle-guide alignment with the in-room tablet device was technically successful in all patients and allowed sampling after a single alignment step in 19/20 (95%) CSRs (median size 14 mm, range: 4-45). Biopsy cores contained cancer in 18/20 patients. There were no per-procedural or post-biopsy complications. Using the tablet device, the mean time to first biopsy was 5.8 ± 1.0 min and the mean total procedure time was 23.7 ± 4.1 min. Use of an in-room tablet device to assist needle-guide alignment was feasible and safe during MR-guided transrectal prostate biopsy. Initial experience indicates potential for procedure time reduction. • Performing MR-guided prostate biopsy using an in-room tablet device is feasible. • CSRs could be sampled after a single alignment step in 19/20 patients. • The mean procedure time for biopsy with the tablet device was 23.7 min.
On fabrication procedures of Li-ion conducting garnets
NASA Astrophysics Data System (ADS)
Hanc, Emil; Zając, Wojciech; Lu, Li; Yan, Binggong; Kotobuki, Masashi; Ziąbka, Magdalena; Molenda, Janina
2017-04-01
Ceramic oxides exhibiting high lithium-ion mobility at room temperature receive broad attention as candidate electrolytes for lithium batteries. Lithium-stuffed garnets from the Li7La3Zr2O12 group seem to be especially promising because of their high ionic conductivity at room temperature and their electrochemical stability. In this work, we discuss factors that affect formation of the garnet in its bulk form or in the form of thick and thin films. We demonstrate that zinc oxide can be applied as a sintering aid that facilitate the formation of the highly conducting cubic Li7La3Zr2O12 garnet phase in a single-step sintering procedure. Based on our experience with the single-step sintering experiments, we successfully fabricated a thick-film membrane consisting of a garnet solid electrolyte using the tape casting technique. In order to reduce the thickness of the electrolyte even further we investigated the fabrication of a thin-film Li7La3Zr2O12 electrolyte by means of the pulsed laser deposition technique.
Tong, Zhihui; Ke, Lu; Li, Baiqiang; Li, Gang; Zhou, Jing; Shen, Xiao; Li, Weiqin; Li, Ning; Li, Jieshou
2016-11-10
In recent years, a step-up approach based on minimally invasive techniques was recommended by latest guidelines as initial invasive treatment for infected pancreatic necrosis (IPN). In this study, we aimed to describe a novel step-up approach for treating IPN consisting of four steps including negative pressure irrigation (NPI) and endoscopic necrosectomy (ED) as a bridge between percutaneous catheter drainage (PCD) and open necrosectomy METHODS: A retrospective review of a prospectively collected internal database of patients with a diagnosis of IPN between Jan, 2012 to Dec, 2012 at a single institution was performed. All patients underwent the same drainage strategy including four steps: PCD, NPI, ED and open necrosectomy. The demographic characteristics and clinical outcomes of study patients were analyzed. A total of 71 consecutive patients (48 males and 23 females) were included in the analysis. No significant procedure-related complication was observed and the overall mortality was +21.1 % (15 of 71 patients). Seven different strategies like PCD+ NPI, PCD+NPI+ED, PCD+open necrosectomy, etcetera, were applied in study patients and a half of them received PCD alone. In general, each patient underwent a median of 2 drainage procedures and the median total drainage duration was 11 days (interquartile range, 6-21days). This four-step approach is effective in treating IPN and adds no extra risk to patients when compared with other latest step-up strategies. The two novel techniques (NPI and ED) could offer distinct clinical benefits without posing unanticipated risks inherent to the procedures.
Vassileva, E; Baeten, H; Hoenig, M
2001-01-02
A slurry sampling-fast program procedure has been developed for the determination of arsenic in plants, soils and sediments by electrothermal atomic absorption spectrometry. Efficiencies of various single and mixed modifiers for thermal stabilization of arsenic and for a better removal of the matrix during pyrolysis step were compared. The influence of the slurry concentration, amounts of modifier and parameters of the pyrolysis step on the As integrated absorbance signals have been studied and a comparison between fast and conventional furnace programs was also made. The ultrasonic agitation of the slurry followed by a fast electrothermal program using an Ir/Mg modifier provides the most consistent performance in terms of precision and accuracy. The reliability of the whole procedure has been compared with results obtained after application of a wet digestion method with an HF step and validated by analyzing eleven certified reference materials. Arsenic detection and quantitation limits expressed on dry sample matter were about 30 and 100 micrograms kg-1, respectively.
Stepwise detection of recombination breakpoints in sequence alignments.
Graham, Jinko; McNeney, Brad; Seillier-Moiseiwitsch, Françoise
2005-03-01
We propose a stepwise approach to identify recombination breakpoints in a sequence alignment. The approach can be applied to any recombination detection method that uses a permutation test and provides estimates of breakpoints. We illustrate the approach by analyses of a simulated dataset and alignments of real data from HIV-1 and human chromosome 7. The presented simulation results compare the statistical properties of one-step and two-step procedures. More breakpoints are found with a two-step procedure than with a single application of a given method, particularly for higher recombination rates. At higher recombination rates, the additional breakpoints were located at the cost of only a slight increase in the number of falsely declared breakpoints. However, a large proportion of breakpoints still go undetected. A makefile and C source code for phylogenetic profiling and the maximum chi2 method, tested with the gcc compiler on Linux and WindowsXP, are available at http://stat-db.stat.sfu.ca/stepwise/ jgraham@stat.sfu.ca.
A numerical method for computing unsteady 2-D boundary layer flows
NASA Technical Reports Server (NTRS)
Krainer, Andreas
1988-01-01
A numerical method for computing unsteady two-dimensional boundary layers in incompressible laminar and turbulent flows is described and applied to a single airfoil changing its incidence angle in time. The solution procedure adopts a first order panel method with a simple wake model to solve for the inviscid part of the flow, and an implicit finite difference method for the viscous part of the flow. Both procedures integrate in time in a step-by-step fashion, in the course of which each step involves the solution of the elliptic Laplace equation and the solution of the parabolic boundary layer equations. The Reynolds shear stress term of the boundary layer equations is modeled by an algebraic eddy viscosity closure. The location of transition is predicted by an empirical data correlation originating from Michel. Since transition and turbulence modeling are key factors in the prediction of viscous flows, their accuracy will be of dominant influence to the overall results.
Valdivia, Maria Pia; Stutman, Dan; Stoeckl, Christian; Mileham, Chad; Begishev, Ildar A; Bromage, Jake; Regan, Sean P
2018-01-10
Talbot-Lau x-ray interferometry uses incoherent x-ray sources to measure refraction index changes in matter. These measurements can provide accurate electron density mapping through phase retrieval. An adaptation of the interferometer has been developed in order to meet the specific requirements of high-energy density experiments. This adaptation is known as a moiré deflectometer, which allows for single-shot capabilities in the form of interferometric fringe patterns. The moiré x-ray deflectometry technique requires a set of object and reference images in order to provide electron density maps, which can be costly in the high-energy density environment. In particular, synthetic reference phase images obtained ex situ through a phase-scan procedure, can provide a feasible solution. To test this procedure, an object phase map was retrieved from a single-shot moiré image obtained from a plasma-produced x-ray source. A reference phase map was then obtained from phase-stepping measurements using a continuous x-ray tube source in a small laboratory setting. The two phase maps were used to retrieve an electron density map. A comparison of the moiré and phase-stepping phase-retrieval methods was performed to evaluate single-exposure plasma electron density mapping for high-energy density and other transient plasma experiments. It was found that a combination of phase-retrieval methods can deliver accurate refraction angle mapping. Once x-ray backlighter quality is optimized, the ex situ method is expected to deliver electron density mapping with improved resolution. The steps necessary for improved diagnostic performance are discussed.
Thermochemical water decomposition processes
NASA Technical Reports Server (NTRS)
Chao, R. E.
1974-01-01
Thermochemical processes which lead to the production of hydrogen and oxygen from water without the consumption of any other material have a number of advantages when compared to other processes such as water electrolysis. It is possible to operate a sequence of chemical steps with net work requirements equal to zero at temperatures well below the temperature required for water dissociation in a single step. Various types of procedures are discussed, giving attention to halide processes, reverse Deacon processes, iron oxide and carbon oxide processes, and metal and alkali metal processes. Economical questions are also considered.
Enzmann, Harald; Schneider, C
2008-07-01
The centralised procedure for marketing authorisation at the European Medicines Agency (EMEA) started more than 10 years ago, offering marketing authorisation for all member states of the European Union in a single procedure. Originally it was a purely optional alternative to the established national procedures; however, its importance has been growing ever since. The introduction of the mandatory scope for several important indications was a crucial step. The increasing importance of the centralised procedure was paralleled by the increasing weight of the EMEA and of the Committee for Human Medicinal Products (CHMP) who is responsible for scientific evaluation in the centralised procedure. This paper describes the basic principles of the centralised procedure including the definitions of the mandatory and optional scope, and how the CHMP works including its responsibility in European referrals that provide a link to national procedures.
Transmission eigenchannels for coherent phonon transport
NASA Astrophysics Data System (ADS)
Klöckner, J. C.; Cuevas, J. C.; Pauly, F.
2018-04-01
We present a procedure to determine transmission eigenchannels for coherent phonon transport in nanoscale devices using the framework of nonequilibrium Green's functions. We illustrate our procedure by analyzing a one-dimensional chain, where all steps can be carried out analytically. More importantly, we show how the procedure can be combined with ab initio calculations to provide a better understanding of phonon heat transport in realistic atomic-scale junctions. In particular, we study the phonon eigenchannels in a gold metallic atomic-size contact and different single-molecule junctions based on molecules such as an alkane chain, a brominated benzene-diamine, where destructive phonon interference effects take place, and a C60 junction.
NASA Astrophysics Data System (ADS)
Kar, Soumen; Rao, V. V.
2018-07-01
In our first attempt to design a single phase R-SFCL in India, we have chosen the typical rating of a medium voltage level (3.3 kVrms, 200 Arms, 1Φ) R-SFCL. The step-by-step design procedure for the R-SFCL involves conductor selection, time dependent electro-thermal simulations and recovery time optimization after fault removal. In the numerical analysis, effective fault limitation for a fault current of 5 kA for the medium voltage level R-SFCL are simulated. Maximum normal state resistance and maximum temperature rise in the SFCL coil during current limitation are estimated using one-dimensional energy balance equation. Further, a cryogenic system is conceptually designed for aforesaid MV level R-SFCL by considering inner and outer vessel materials, wall-thickness and thermal insulation which can be used for R-SFCL system. Finally, the total thermal load is calculated for the designed R-SFCL cryostat to select a suitable cryo-refrigerator for LN2 re-condensation.
Cardinale, Jens; Martin, René; Remde, Yvonne; Schäfer, Martin; Hienzsch, Antje; Hübner, Sandra; Zerges, Anna-Maria; Marx, Heike; Hesse, Ronny; Weber, Klaus; Smits, Rene; Hoepping, Alexander; Müller, Marco; Neels, Oliver C.; Kopka, Klaus
2017-01-01
Radiolabeled tracers targeting the prostate-specific membrane antigen (PSMA) have become important radiopharmaceuticals for the PET-imaging of prostate cancer. In this connection, we recently developed the fluorine-18-labelled PSMA-ligand [18F]PSMA-1007 as the next generation radiofluorinated Glu-ureido PSMA inhibitor after [18F]DCFPyL and [18F]DCFBC. Since radiosynthesis so far has been suffering from rather poor yields, novel procedures for the automated radiosyntheses of [18F]PSMA-1007 have been developed. We herein report on both the two-step and the novel one-step procedures, which have been performed on different commonly-used radiosynthesisers. Using the novel one-step procedure, the [18F]PSMA-1007 was produced in good radiochemical yields ranging from 25 to 80% and synthesis times of less than 55 min. Furthermore, upscaling to product activities up to 50 GBq per batch was successfully conducted. All batches passed quality control according to European Pharmacopoeia standards. Therefore, we were able to disclose a new, simple and, at the same time, high yielding production pathway for the next generation PSMA radioligand [18F]PSMA-1007. Actually, it turned out that the radiosynthesis is as easily realised as the well-known [18F]FDG synthesis and, thus, transferable to all currently-available radiosynthesisers. Using the new procedures, the clinical daily routine can be sustainably supported in-house even in larger hospitals by a single production batch. PMID:28953234
A new procedure for fast soft staining of BN-PAGEs on photosynthetic complexes.
Farci, Domenica; Kirkpatrick, Joanna; Piano, Dario
2017-02-01
We report a fast and sensitive procedure for blue native PAGE staining, in which the conventional staining step with CBB is avoided. After running, a short exposure to a mix of polar protic solvents (ethanol and acetic acid) leads to a fast and selective removal of the dye from the migration front and a specific binding to the protein bands, while the rest undergo a selective and complete background removal, leading to an intense contrast. This single-step staining-destaining technique is useful in protein samples that bind colored cofactors such as photosystems, which can be selectively discerned by their characteristic green color. After the staining of such samples, the green color persists, while the other unpigmented protein complexes and the molecular standard remain CBB stained, creating a useful reference system for the assignment of the bands. The advantages and chemical basis of this staining procedure are discussed. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Evaluation of atomic pressure in the multiple time-step integration algorithm.
Andoh, Yoshimichi; Yoshii, Noriyuki; Yamada, Atsushi; Okazaki, Susumu
2017-04-15
In molecular dynamics (MD) calculations, reduction in calculation time per MD loop is essential. A multiple time-step (MTS) integration algorithm, the RESPA (Tuckerman and Berne, J. Chem. Phys. 1992, 97, 1990-2001), enables reductions in calculation time by decreasing the frequency of time-consuming long-range interaction calculations. However, the RESPA MTS algorithm involves uncertainties in evaluating the atomic interaction-based pressure (i.e., atomic pressure) of systems with and without holonomic constraints. It is not clear which intermediate forces and constraint forces in the MTS integration procedure should be used to calculate the atomic pressure. In this article, we propose a series of equations to evaluate the atomic pressure in the RESPA MTS integration procedure on the basis of its equivalence to the Velocity-Verlet integration procedure with a single time step (STS). The equations guarantee time-reversibility even for the system with holonomic constrants. Furthermore, we generalize the equations to both (i) arbitrary number of inner time steps and (ii) arbitrary number of force components (RESPA levels). The atomic pressure calculated by our equations with the MTS integration shows excellent agreement with the reference value with the STS, whereas pressures calculated using the conventional ad hoc equations deviated from it. Our equations can be extended straightforwardly to the MTS integration algorithm for the isothermal NVT and isothermal-isobaric NPT ensembles. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.
NASA Technical Reports Server (NTRS)
Bendura, R. J.; Renfroe, P. G.
1974-01-01
A detailed discussion of the application of a previously method to determine vehicle flight attitude using a single camera onboard the vehicle is presented with emphasis on the digital computer program format and data reduction techniques. Application requirements include film and earth-related coordinates of at least two landmarks (or features), location of the flight vehicle with respect to the earth, and camera characteristics. Included in this report are a detailed discussion of the program input and output format, a computer program listing, a discussion of modifications made to the initial method, a step-by-step basic data reduction procedure, and several example applications. The computer program is written in FORTRAN 4 language for the Control Data 6000 series digital computer.
The current role of on-line extraction approaches in clinical and forensic toxicology.
Mueller, Daniel M
2014-08-01
In today's clinical and forensic toxicological laboratories, automation is of interest because of its ability to optimize processes, to reduce manual workload and handling errors and to minimize exposition to potentially infectious samples. Extraction is usually the most time-consuming step; therefore, automation of this step is reasonable. Currently, from the field of clinical and forensic toxicology, methods using the following on-line extraction techniques have been published: on-line solid-phase extraction, turbulent flow chromatography, solid-phase microextraction, microextraction by packed sorbent, single-drop microextraction and on-line desorption of dried blood spots. Most of these published methods are either single-analyte or multicomponent procedures; methods intended for systematic toxicological analysis are relatively scarce. However, the use of on-line extraction will certainly increase in the near future.
Detailed analysis of complex single molecule FRET data with the software MASH
NASA Astrophysics Data System (ADS)
Hadzic, Mélodie C. A. S.; Kowerko, Danny; Börner, Richard; Zelger-Paulus, Susann; Sigel, Roland K. O.
2016-04-01
The processing and analysis of surface-immobilized single molecule FRET (Förster resonance energy transfer) data follows systematic steps (e.g. single molecule localization, clearance of different sources of noise, selection of the conformational and kinetic model, etc.) that require a solid knowledge in optics, photophysics, signal processing and statistics. The present proceeding aims at standardizing and facilitating procedures for single molecule detection by guiding the reader through an optimization protocol for a particular experimental data set. Relevant features were determined from single molecule movies (SMM) imaging Cy3- and Cy5-labeled Sc.ai5γ group II intron molecules synthetically recreated, to test the performances of four different detection algorithms. Up to 120 different parameterizations per method were routinely evaluated to finally establish an optimum detection procedure. The present protocol is adaptable to any movie displaying surface-immobilized molecules, and can be easily reproduced with our home-written software MASH (multifunctional analysis software for heterogeneous data) and script routines (both available in the download section of www.chem.uzh.ch/rna).
Learning curve for peroral endoscopic myotomy
El Zein, Mohamad; Kumbhari, Vivek; Ngamruengphong, Saowanee; Carson, Kathryn A.; Stein, Ellen; Tieu, Alan; Chaveze, Yamile; Ismail, Amr; Dhalla, Sameer; Clarke, John; Kalloo, Anthony; Canto, Marcia Irene; Khashab, Mouen A.
2016-01-01
Background and study aims: Although peroral endoscopic myotomy (POEM) is being performed more frequently, the learning curve for gastroenterologists performing the procedure has not been well studied. The aims of this study were to define the learning curve for POEM and determine which preoperative and intraoperative factors predict the time that will be taken to complete the procedure and its different steps. Patients and methods: Consecutive patients who underwent POEM performed by a single expert gastroenterologist for the treatment of achalasia or spastic esophageal disorders were included. The POEM procedure was divided into four steps: mucosal entry, submucosal tunneling, myotomy, and closure. Nonlinear regression was used to determine the POEM learning plateau and calculate the learning rate. Results: A total of 60 consecutive patients underwent POEM in an endoscopy suite. The median length of procedure (LOP) was 88 minutes (range 36 – 210), and the mean (± standard deviation [SD]) LOP per centimeter of myotomy was 9 ± 5 minutes. The total operative time decreased significantly as experience increased (P < 0.001), with a “learning plateau” at 102 minutes and a “learning rate” of 13 cases. The mucosal entry, tunneling, and closure times decreased significantly with experience (P < 0.001). The myotomy time showed no significant decrease with experience (P = 0.35). When the mean (± SD) total procedure times for the learning phase and the corresponding comparator groups were compared, a statistically significant difference was observed between procedures 11 – 15 and procedures 16 – 20 (15.5 ± 2.4 min/cm and 10.1 ± 2.7 min/cm, P = 0.01) but not thereafter. A higher case number was significantly associated with a decreased LOP (P < 0.001). Conclusion: In this single-center retrospective study, the minimum threshold number of cases required for an expert interventional endoscopist performing POEM to reach a plateau approached 13. PMID:27227118
Cai, Xi; Han, Guang; Song, Xin; Wang, Jinkuan
2017-11-01
single-camera-based gait monitoring is unobtrusive, inexpensive, and easy-to-use to monitor daily gait of seniors in their homes. However, most studies require subjects to walk perpendicularly to camera's optical axis or along some specified routes, which limits its application in elderly home monitoring. To build unconstrained monitoring environments, we propose a method to measure step length symmetry ratio (a useful gait parameter representing gait symmetry without significant relationship with age) from unconstrained straight walking using a single camera, without strict restrictions on walking directions or routes. according to projective geometry theory, we first develop a calculation formula of step length ratio for the case of unconstrained straight-line walking. Then, to adapt to general cases, we propose to modify noncollinear footprints, and accordingly provide general procedure for step length ratio extraction from unconstrained straight walking. Our method achieves a mean absolute percentage error (MAPE) of 1.9547% for 15 subjects' normal and abnormal side-view gaits, and also obtains satisfactory MAPEs for non-side-view gaits (2.4026% for 45°-view gaits and 3.9721% for 30°-view gaits). The performance is much better than a well-established monocular gait measurement system suitable only for side-view gaits with a MAPE of 3.5538%. Independently of walking directions, our method can accurately estimate step length ratios from unconstrained straight walking. This demonstrates our method is applicable for elders' daily gait monitoring to provide valuable information for elderly health care, such as abnormal gait recognition, fall risk assessment, etc. single-camera-based gait monitoring is unobtrusive, inexpensive, and easy-to-use to monitor daily gait of seniors in their homes. However, most studies require subjects to walk perpendicularly to camera's optical axis or along some specified routes, which limits its application in elderly home monitoring. To build unconstrained monitoring environments, we propose a method to measure step length symmetry ratio (a useful gait parameter representing gait symmetry without significant relationship with age) from unconstrained straight walking using a single camera, without strict restrictions on walking directions or routes. according to projective geometry theory, we first develop a calculation formula of step length ratio for the case of unconstrained straight-line walking. Then, to adapt to general cases, we propose to modify noncollinear footprints, and accordingly provide general procedure for step length ratio extraction from unconstrained straight walking. Our method achieves a mean absolute percentage error (MAPE) of 1.9547% for 15 subjects' normal and abnormal side-view gaits, and also obtains satisfactory MAPEs for non-side-view gaits (2.4026% for 45°-view gaits and 3.9721% for 30°-view gaits). The performance is much better than a well-established monocular gait measurement system suitable only for side-view gaits with a MAPE of 3.5538%. Independently of walking directions, our method can accurately estimate step length ratios from unconstrained straight walking. This demonstrates our method is applicable for elders' daily gait monitoring to provide valuable information for elderly health care, such as abnormal gait recognition, fall risk assessment, etc.
Xu, Dongsheng; Shao, Huikai; Luo, Rongying; Wang, Qiqin; Sánchez-López, Elena; Fanali, Salvatore; Marina, Maria Luisa; Jiang, Zhengjin
2018-07-06
A facile single-step preparation strategy for fabricating vancomycin functionalized organic polymer-based monolith within 100μm fused-silica capillary was developed. The synthetic chiral functional monomer, i.e 2-isocyanatoethyl methacrylate (ICNEML) derivative of vancomycin, was co-polymerized with the cross-linker ethylene dimethacrylate (EDMA) in the presence of methanol and dimethyl sulfoxide as the selected porogens. The co-polymerization conditions were systematically optimized in order to obtain satisfactory column performance. Adequate permeability, stability and column morphology were observed for the optimized poly(ICNEML-vancomycin-co-EDMA) monolith. A series of chiral drugs were evaluated on the monolith in either polar organic-phase or reversed-phase modes. After the optimization of separation conditions, baseline or partial enantioseparation were obtained for series of drugs including thalidomide, colchicine, carteolol, salbutamol, clenbuterol and several other β-blockers. The proposed single-step approach not only resulted in a vancomycin functionalized organic polymer-based monolith with acceptable performance, but also significantly simplified the preparation procedure by reducing time and labor. Copyright © 2018 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Hamilton, Jason S.; Aguilar, Roberto; Petros, Robby A.; Verbeck, Guido F.
2017-05-01
The cellular metabolome is considered to be a representation of cellular phenotype and cellular response to changes to internal or external events. Methods to expand the coverage of the expansive physiochemical properties that makeup the metabolome currently utilize multi-step extractions and chromatographic separations prior to chemical detection, leading to lengthy analysis times. In this study, a single-step procedure for the extraction and separation of a sample using a micro-capillary as a separatory funnel to achieve analyte partitioning within an organic/aqueous immiscible solvent system is described. The separated analytes are then spotted for MALDI-MS imaging and distribution ratios are calculated. Initially, the method is applied to standard mixtures for proof of partitioning. The extraction of an individual cell is non-reproducible; therefore, a broad chemical analysis of metabolites is necessary and will be illustrated with the one-cell analysis of a single Snu-5 gastric cancer cell taken from a cellular suspension. The method presented here shows a broad partitioning dynamic range as a single-step method for lipid analysis demonstrating a decrease in ion suppression often present in MALDI analysis of lipids.
Epiretinal membrane negative staining and double peeling in a single block with Brilliant Blue G.
Martins, David; Neves, Pedro
2018-01-01
To describe a surgical technique for combined peeling of epiretinal and internal limiting membranes. The authors present their procedure of choice for epiretinal membrane surgery: negative staining effect using Brilliant Blue G and single block removal of the epiretinal and internal limiting membranes in a single step. A total of 26 eyes were operated with the described technique. In all cases, the peeling was performed successfully and with no complications. Minimum postoperative follow-up was 12 months. There were no recurrences of epiretinal membranes. The ideal surgical approach for epiretinal membranes should attempt to reduce mechanical trauma, light exposure, and dye toxicity.
Method of casting patterned dielectric structures
Poco, John F.; Hrubesh, Lawrence W.
2001-01-01
A pattern of dielectric structures are formed directly on a substrate in a single step using sol-gel chemistry and molding procedures. The resulting dielectric structures are useful in vacuum applications for electronic devices. Porous, lightweight structures having a high aspect ratio that are suitable for use as spacers between the faceplate and baseplate of a field emission display can be manufactured using this method.
ERIC Educational Resources Information Center
Ong, Jun-Yang; Chan, Shang-Ce; Hoang, Truong-Giang
2018-01-01
A Sonogashira experiment was transformed into a problem-based learning platform for third-year undergraduate students. Given a target that could be synthesized in a single step, students worked in groups to investigate which method was the best for large-scale production. Through this practical scenario, students learn to conduct a literature…
Kaluzny, Bartlomiej J; Cieslinska, Iwona; Mosquera, Samuel A; Verma, Shwetabh
2016-02-01
Transepithelial photorefractive keratectomy (tPRK), where both the epithelium and stroma are removed in a single-step, is a relatively new procedure of laser refractive error correction. This study compares the 3-month results of myopia and compound myopic astigmatism correction by tPRK or conventional alcohol-assisted PRK (aaPRK).This prospective, nonrandomized, case-control study recruited 148 consecutive patients; 93 underwent tPRK (173 eyes) and 55 aaPRK (103 eyes). Refractive results, predictability, safety, and efficacy were evaluated during the 3-month follow-up. The main outcome measures were uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), and mean refractive spherical equivalent (MRSE).Mean preoperative MRSE was -4.30 ± 1.72 D and -4.33 ± 1.96 D, respectively (P = 0.87). The 3-month follow-up rate was 82.1% in the tPRK group (n = 145) and 86.4% in aaPRK group (n = 90), P = 0.81. Postoperative UDVA was 20/20 or better in 97% and 94% of eyes, respectively (P = 0.45). In the tPRK and aaPRK groups, respectively, 13% and 21% of eyes lost 1 line of CDVA, and 30% and 31% gained 1 or 2 lines (P = 0.48). Mean postoperative MRSE was -0.14 ± 0.26 D in the tPRK group and -0.12 ± 0.20 D in the aaPRK group (P = 0.9). The correlation between attempted versus achieved MRSE was equally high in both groups.Single-step transepithelial PRK and conventional PRK provide very similar results 3 months postoperatively. These procedures are predictable, effective, and safe for correction of myopia and compound myopic astigmatism.
Abusedera, Mohammad; Alkady, Ola
2016-04-01
Studies have shown that small-catheter pleural effusion drainage is safe and has a lower complication rate. Our objective was to evaluate the outcomes and the safety of the single-step trocar or the modified Seldinger technique. A total of 124 patients (83 men and 41 women), with mean age of 46±18 years and mean duration of drainage 5.3±2 days, were include in the study. The trocar technique was attempted in 201 (86.5%) cases, and the modified Seldinger technique was used in 38 (16.5%) cases. Technical success was obtained in 96% for the trocar technique and in 100% for the modified Seldinger technique. The procedure time for the trocar and the modified Seldinger techniques was approximately 7 and 12 minutes, respectively (P-value=0.02). The overall success rate was 72.9%. The success rate was highest for massive transudative effusions (98%) followed by malignant effusions (87%), and it was least for parapneumonic effusion/empyema (72 %). Pneumothorax occurred in 10.5% (n=4) for modified Seldinger versus 0.5% (n=1) (P=0.12) for trocar, whereas bleeding occurred in 0% for modified Seldinger and in 1% (n=2) for trocar (P=0.04). The single-step trocar technique was technically unsuccessful in 8 cases (7 had empyema with narrow intercostal spaces and one had kyphoscoliosis); technical success was achieved by using the modified Seldinger. Ultrasound-guided pleural effusion drainage by catheter insertion is a safe and effective procedure. The success rate is low when the effusion is loculated and septated. Both the trocar and the modified Seldinger techniques can be used. The trocar technique is faster and easier.
Single-crossover recombination in discrete time.
von Wangenheim, Ute; Baake, Ellen; Baake, Michael
2010-05-01
Modelling the process of recombination leads to a large coupled nonlinear dynamical system. Here, we consider a particular case of recombination in discrete time, allowing only for single crossovers. While the analogous dynamics in continuous time admits a closed solution (Baake and Baake in Can J Math 55:3-41, 2003), this no longer works for discrete time. A more general model (i.e. without the restriction to single crossovers) has been studied before (Bennett in Ann Hum Genet 18:311-317, 1954; Dawson in Theor Popul Biol 58:1-20, 2000; Linear Algebra Appl 348:115-137, 2002) and was solved algorithmically by means of Haldane linearisation. Using the special formalism introduced by Baake and Baake (Can J Math 55:3-41, 2003), we obtain further insight into the single-crossover dynamics and the particular difficulties that arise in discrete time. We then transform the equations to a solvable system in a two-step procedure: linearisation followed by diagonalisation. Still, the coefficients of the second step must be determined in a recursive manner, but once this is done for a given system, they allow for an explicit solution valid for all times.
Bremner, P D; Blacklock, C J; Paganga, G; Mullen, W; Rice-Evans, C A; Crozier, A
2000-06-01
After minimal sample preparation, two different HPLC methodologies, one based on a single gradient reversed-phase HPLC step, the other on multiple HPLC runs each optimised for specific components, were used to investigate the composition of flavonoids and phenolic acids in apple and tomato juices. The principal components in apple juice were identified as chlorogenic acid, phloridzin, caffeic acid and p-coumaric acid. Tomato juice was found to contain chlorogenic acid, caffeic acid, p-coumaric acid, naringenin and rutin. The quantitative estimates of the levels of these compounds, obtained with the two HPLC procedures, were very similar, demonstrating that either method can be used to analyse accurately the phenolic components of apple and tomato juices. Chlorogenic acid in tomato juice was the only component not fully resolved in the single run study and the multiple run analysis prior to enzyme treatment. The single run system of analysis is recommended for the initial investigation of plant phenolics and the multiple run approach for analyses where chromatographic resolution requires improvement.
Memory Effect Manifested by a Boson Peak in Metallic Glass.
Luo, P; Li, Y Z; Bai, H Y; Wen, P; Wang, W H
2016-04-29
We explore the correlation between a boson peak and structural relaxation in a typical metallic glass. Consistent with enthalpy recovery, a boson peak shows a memory effect in an aging-and-scan procedure. Single-step isothermal aging produces a monotonic decrease of enthalpy and boson peak intensity; for double-step isothermal aging, both enthalpy and boson peak intensity experience, coincidently, an incipient increase to a maximum and a subsequent decrease toward the equilibrium state. Our results indicate a direct link between slow structural relaxation and fast boson peak dynamics, which presents a profound understanding of the two dynamic behaviors in glass.
Olaya-Castro, Alexandra; Johnson, Neil F; Quiroga, Luis
2005-03-25
We propose a physically realizable machine which can either generate multiparticle W-like states, or implement high-fidelity 1-->M (M=1,2,...infinity) anticloning of an arbitrary qubit state, in a single step. This universal machine acts as a catalyst in that it is unchanged after either procedure, effectively resetting itself for its next operation. It possesses an inherent immunity to decoherence. Most importantly in terms of practical multiparty quantum communication, the machine's robustness in the presence of decoherence actually increases as the number of qubits M increases.
Di Muccio, A; Barbini, D A; Generali, T; Pelosi, P; Ausili, A; Vergori, F; Camoni, I
1997-03-21
Disposable, ready-to-use cartridges filled with macroporous diatomaceous material are used to carry out a partition clean-up that, in a single step, is capable of transferring pesticide residues from aqueous acetone extracts into light petroleum-dichloromethane (75:25, v/v). This procedure takes the place of some functions (such as separatory-funnel partition, drying over anhydrous sodium sulphate and partial adsorption clean-up) usually performed by separate steps in classical schemes. Fourteen pyrethroid pesticides, including tefluthrin, tetramethrin, cyphenothrin, cyfluthrin, flucythrinate, tau-fluvalinate, deltamethrin, bioallethrin, fenpropathrin, lambda-cyhalothrin, permethrin, alpha-cypermethrin, esfenvalerate and tralomethrin were determined using the described procedure with satisfactory recoveries for most of them, at spiking levels ranging from 0.08 to 0.82 mg/kg for the different compounds. Crops subjected to the described procedure included strawberry, apple, and orange gave extracts containing a mass of co-extractives that was between 5 and 30 mg. Compared with classical schemes, the described procedure is simple, less labour intensive, allows parallel handling of several extracts and does not require the preparation and maintenance of equipment. Troublesome emulsions such as those frequently observed in separation funnel partitioning do not occur.
Step-reduced synthesis of starch-silver nanoparticles.
Raghavendra, Gownolla Malegowd; Jung, Jeyoung; Kim, Dowan; Seo, Jongchul
2016-05-01
In the present process, silver nanoparticles were directly synthesized in a single step by microwave irradiation of a mixture of starch, silver nitrate, and deionized water. This is different from the commonly adopted procedure for starch-silver nanoparticle synthesis in which silver nanoparticles are synthesized by preparing a starch solution as a reaction medium first. Thus, the additional step associated with the preparation of the starch solution was eliminated. In addition, no additional reducing agent was utilized. The adopted method was facile and straight forward, affording spherical silver nanoparticles with diameter below 10nm that exhibited good antibacterial activity. Further, influence of starch on the size of the silver nanoparticles was noticed. Copyright © 2016 Elsevier B.V. All rights reserved.
Bhardwaj, Ashu; Sultan, Nishat; Sawai, Madhuri; Jafri, Zeba
2016-01-01
Moderate-to-severe chronic periodontitis results in clinical loss of attachment, reduced width of attached gingiva (AG), periodontal pockets beyond mucogingival junction (MGJ), gingival recession, loss of alveolar bone, and decreased vestibular depth (VD). The encroachment of frenal and muscle attachments on marginal gingiva increases the rate of progression of periodontal pockets, prevents healing, and causes their recurrence after therapy. Loss of VD and AG associated with continuous progression of pocket formation and bone loss requires two-stage surgical procedures. In this article, one-stage surgical procedure is being described for the first time, to treat the periodontal pockets extending beyond the MGJ by periodontal flap surgery along with vestibular deepening with diode laser to increase the AG. One-step surgical technique is illustrated whereby pocket therapy with reconstruction of lost periodontal tissues can be done along with gingival augmentation by vestibular deepening. PMID:29238149
Jiang, Yaping; Shibamoto, Takayuki; Li, Yanjie; Pan, Canping
2013-01-01
Rape crops with residues of acetamiprid, azoxystrobin and methidathion incurred from field trials were used to evaluate the effect of household and commercial crude rapeseed oil processing on the transfer of pesticide residues. The pesticides were applied at exaggerated dosage to quantify residue levels in processed samples. The processing procedure was conducted as closely as possible to the actual conditions in practice. The conditioning step removed at least 30% of pesticides, while azoxystrobin and methidathion were concentrated by at least 15% at the single pressing step. The residue level of methidathion was concentrated with a processing factor (PF) of 1.07, while azoxystrobin and acetamiprid decreased with PFs of 0.67 and 0.04, respectively, after all processing procedures. The overall magnitudes of acetamiprid, azoxystrobin and methidathion in rapeseed oil and meal were all decreased after processing compared with the magnitude of those in raw rapeseed.
Wiring up pre-characterized single-photon emitters by laser lithography
NASA Astrophysics Data System (ADS)
Shi, Q.; Sontheimer, B.; Nikolay, N.; Schell, A. W.; Fischer, J.; Naber, A.; Benson, O.; Wegener, M.
2016-08-01
Future quantum optical chips will likely be hybrid in nature and include many single-photon emitters, waveguides, filters, as well as single-photon detectors. Here, we introduce a scalable optical localization-selection-lithography procedure for wiring up a large number of single-photon emitters via polymeric photonic wire bonds in three dimensions. First, we localize and characterize nitrogen vacancies in nanodiamonds inside a solid photoresist exhibiting low background fluorescence. Next, without intermediate steps and using the same optical instrument, we perform aligned three-dimensional laser lithography. As a proof of concept, we design, fabricate, and characterize three-dimensional functional waveguide elements on an optical chip. Each element consists of one single-photon emitter centered in a crossed-arc waveguide configuration, allowing for integrated optical excitation and efficient background suppression at the same time.
GENESUS: a two-step sequence design program for DNA nanostructure self-assembly.
Tsutsumi, Takanobu; Asakawa, Takeshi; Kanegami, Akemi; Okada, Takao; Tahira, Tomoko; Hayashi, Kenshi
2014-01-01
DNA has been recognized as an ideal material for bottom-up construction of nanometer scale structures by self-assembly. The generation of sequences optimized for unique self-assembly (GENESUS) program reported here is a straightforward method for generating sets of strand sequences optimized for self-assembly of arbitrarily designed DNA nanostructures by a generate-candidates-and-choose-the-best strategy. A scalable procedure to prepare single-stranded DNA having arbitrary sequences is also presented. Strands for the assembly of various structures were designed and successfully constructed, validating both the program and the procedure.
NASA Astrophysics Data System (ADS)
Nguyen, L. T.; Modrak, R. T.; Saenger, E. H.; Tromp, J.
2017-12-01
Reverse-time migration (RTM) can reconstruct reflectors and scatterers by cross-correlating the source wavefield and the receiver wavefield given a known velocity model of the background. In nondestructive testing, however, the engineered structure under inspection is often composed of layers of various materials and the background material has been degraded non-uniformly because of environmental or operational effects. On the other hand, ultrasonic waveform tomography based on the principles of full-waveform inversion (FWI) has succeeded in detecting anomalous features in engineered structures. But the building of the wave velocity model of the comprehensive small-size and high-contrast defect(s) is difficult because it requires computationally expensive high-frequency numerical wave simulations and an accurate understanding of large-scale background variations of the engineered structure.To reduce computational cost and improve detection of small defects, a useful approach is to divide the waveform tomography procedure into two steps: first, a low-frequency model-building step aimed at recovering background structure using FWI, and second, a high-frequency imaging step targeting defects using RTM. Through synthetic test cases, we show that the two-step procedure appears more promising in most cases than a single-step inversion. In particular, we find that the new workflow succeeds in the challenging scenario where the defect lies along preexisting layer interface in a composite bridge deck and in related experiments involving noisy data or inaccurate source parameters. The results reveal the potential of the new wavefield imaging method and encourage further developments in data processing, enhancing computation power, and optimizing the imaging workflow itself so that the procedure can efficiently be applied to geometrically complex 3D solids and waveguides. Lastly, owing to the scale invariance of the elastic wave equation, this imaging procedure can be transferred to applications in regional scales as well.
Guo, Hongshan; Zhu, Ping; Guo, Fan; Li, Xianlong; Wu, Xinglong; Fan, Xiaoying; Wen, Lu; Tang, Fuchou
2015-05-01
The heterogeneity of DNA methylation within a population of cells necessitates DNA methylome profiling at single-cell resolution. Recently, we developed a single-cell reduced-representation bisulfite sequencing (scRRBS) technique in which we modified the original RRBS method by integrating all the experimental steps before PCR amplification into a single-tube reaction. These modifications enable scRRBS to provide digitized methylation information on ∼1 million CpG sites within an individual diploid mouse or human cell at single-base resolution. Compared with the single-cell bisulfite sequencing (scBS) technique, scRRBS covers fewer CpG sites, but it provides better coverage for CpG islands (CGIs), which are likely to be the most informative elements for DNA methylation. The entire procedure takes ∼3 weeks, and it requires strong molecular biology skills.
New organophilic kaolin clays based on single-point grafted 3-aminopropyl dimethylethoxysilane.
Zaharia, A; Perrin, F-X; Teodorescu, M; Radu, A-L; Iordache, T-V; Florea, A-M; Donescu, D; Sarbu, A
2015-10-14
In this study, the organophilization procedure of kaolin rocks with a monofunctional ethoxysilane- 3 aminopropyl dimethyl ethoxysilane (APMS) is depicted for the first time. The two-step organophilization procedure, including dimethyl sulfoxide intercalation and APMS grafting onto the inner hydroxyl surface of kaolinite (the mineral) layers was tested for three sources of kaolin rocks (KR, KC and KD) with various morphologies and kaolinite compositions. The load of APMS in the kaolinite interlayer space was higher than that of 3-aminopropyl triethoxysilane (APTS) due to the single-point grafting nature of the organophilization reaction. A higher long-distance order of kaolinite layers with low staking was obtained for the APMS, due to a more controllable organiphilization reaction. Last but not least, the solid state (29)Si-NMR tests confirmed the single-point grafting mechanism of APMS, corroborating monodentate fixation on the kaolinite hydroxyl facets, with no contribution to the bidentate or tridentate fixation as observed for APTS.
Fibulin-1 purification from human plasma using affinity chromatography on Factor H-Sepharose
DiScipio, Richard G.; Liddington, Robert C.; Schraufstatter, Ingrid U.
2016-01-01
A method is reported to purify Fibulin-1 from human plasma resulting in a 36% recovery. The steps involve removal of the cryoglobulin and the vitamin K dependent proteins followed by polyethylene glycol and ammonium sulfate precipitations, DEAE-Sephadex column chromatography and finally Factor H-Sepharose affinity purification. The procedure is designed to be integrated into an overall scheme for the isolation of over 30 plasma proteins from a single batch of human plasma. Results from mass spectroscopy, SDS-PAGE, and Western blotting indicate that human plasma Fibulin-1 is a single chain of the largest isotype. Functional binding assays demonstrated calcium ion dependent interaction of Fibulin-1 for fibrinogen, fibronectin, and Factor H. The procedure described is the first to our knowledge that enables a large scale purification of Fibulin-1 from human plasma. PMID:26826315
14 CFR 302.37 - Waiver of procedural steps after hearing.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 4 2010-01-01 2010-01-01 false Waiver of procedural steps after hearing... Applicability Oral Evidentiary Hearing Proceedings § 302.37 Waiver of procedural steps after hearing. The parties to any proceeding may agree to waive any one or more of the procedural steps provided in § 302.29...
USDA-ARS?s Scientific Manuscript database
In this study, an ultra sensitive and quantitative diagnostic system for “Candidatus Liberibacter asiaticus” was developed. This system adapts a nested PCR and Taq-Man PCR in a single closed tube. The procedure involves two steps of PCR using the species specific outer and inner primer pairs. Differ...
USDA-ARS?s Scientific Manuscript database
Clinical mastitis (CM) is one of the health disorders with largest impacts on dairy farming profitability and animal welfare. Previous studies have consistently shown that CM is under genetic control but knowledge about regions of the genome associated with resistance to CM in US Holstein is lacking...
Jeong, Jong Seok; Mkhoyan, K Andre
2016-06-01
Acquiring an atomic-resolution compositional map of crystalline specimens has become routine practice, thus opening possibilities for extracting subatomic information from such maps. A key challenge for achieving subatomic precision is the improvement of signal-to-noise ratio (SNR) of compositional maps. Here, we report a simple and reliable solution for achieving high-SNR energy-dispersive X-ray (EDX) spectroscopy spectrum images for individual atomic columns. The method is based on standard cross-correlation aided by averaging of single-column EDX maps with modifications in the reference image. It produces EDX maps with minimal specimen drift, beam drift, and scan distortions. Step-by-step procedures to determine a self-consistent reference map with a discussion on the reliability, stability, and limitations of the method are presented here.
Estimation of the transmissivity of thin leaky-confined aquifers from single-well pumping tests
NASA Astrophysics Data System (ADS)
Worthington, Paul F.
1981-01-01
Data from the quasi-equilibrium phases of a step-drawdown test are used to evaluate the coefficient of non-linear head losses subject to the assumption of a constant effective well radius. After applying a well-loss correction to the observed drawdowns of the first step, an approximation method is used to estimate a pseudo-transmissivity of the aquifer from a single value of time-variant drawdown. The pseudo-transmissivities computed for each of a sequence of values of time pass through a minimum when there is least manifestation of casing-storage and leakage effects, phenomena to which pumping-test data of this kind are particularly susceptible. This minimum pseudo-transmissivity, adjusted for partial penetration effects where appropriate, constitutes the best possible estimate of aquifer transmissivity. The ease of application of the overall procedure is illustrated by a practical example.
Pre-Steady-State Kinetic Analysis of Single-Nucleotide Incorporation by DNA Polymerases
Su, Yan; Guengerich, F. Peter
2016-01-01
Pre-steady-state kinetic analysis is a powerful and widely used method to obtain multiple kinetic parameters. This protocol provides a step-by-step procedure for pre-steady-state kinetic analysis of single-nucleotide incorporation by a DNA polymerase. It describes the experimental details of DNA substrate annealing, reaction mixture preparation, handling of the RQF-3 rapid quench-flow instrument, denaturing polyacrylamide DNA gel preparation, electrophoresis, quantitation, and data analysis. The core and unique part of this protocol is the rationale for preparation of the reaction mixture (the ratio of the polymerase to the DNA substrate) and methods for conducting pre-steady-state assays on an RQF-3 rapid quench-flow instrument, as well as data interpretation after analysis. In addition, the methods for the DNA substrate annealing and DNA polyacrylamide gel preparation, electrophoresis, quantitation and analysis are suitable for use in other studies. PMID:27248785
Dawidowicz, Andrzej L; Wianowska, Dorota
2005-04-29
Pressurised liquid extraction (PLE) is recognised as one of the most effective sample preparation methods. Despite the enhanced extraction power of PLE, the full recovery of an analyte from plant material may require multiple extractions of the same sample. The presented investigations show the possibility of estimating the true concentration value of an analyte in plant material employing one-cycle PLE in which plant samples of different weight are used. The performed experiments show a linear dependence between the reciprocal value of the analyte amount (E*), extracted in single-step PLE from a plant matrix, and the ratio of plant material mass to extrahent volume (m(p)/V(s)). Hence, time-consuming multi-step PLE can be replaced by a few single-step PLEs performed at different (m(p)/V(s)) ratios. The concentrations of rutin in Sambucus nigra L. and caffeine in tea and coffee estimated by means of the tested procedure are almost the same as their concentrations estimated by multiple PLE.
Topology optimization of a gas-turbine engine part
NASA Astrophysics Data System (ADS)
Faskhutdinov, R. N.; Dubrovskaya, A. S.; Dongauzer, K. A.; Maksimov, P. V.; Trufanov, N. A.
2017-02-01
One of the key goals of aerospace industry is a reduction of the gas turbine engine weight. The solution of this task consists in the design of gas turbine engine components with reduced weight retaining their functional capabilities. Topology optimization of the part geometry leads to an efficient weight reduction. A complex geometry can be achieved in a single operation with the Selective Laser Melting technology. It should be noted that the complexity of structural features design does not affect the product cost in this case. Let us consider a step-by-step procedure of topology optimization by an example of a gas turbine engine part.
NASA Technical Reports Server (NTRS)
Chang, S. C.
1986-01-01
A two-step semidirect procedure is developed to accelerate the one-step procedure described in NASA TP-2529. For a set of constant coefficient model problems, the acceleration factor increases from 1 to 2 as the one-step procedure convergence rate decreases from + infinity to 0. It is also shown numerically that the two-step procedure can substantially accelerate the convergence of the numerical solution of many partial differential equations (PDE's) with variable coefficients.
Sampling large landscapes with small-scale stratification-User's Manual
Bart, Jonathan
2011-01-01
This manual explains procedures for partitioning a large landscape into plots, assigning the plots to strata, and selecting plots in each stratum to be surveyed. These steps are referred to as the "sampling large landscapes (SLL) process." We assume that users of the manual have a moderate knowledge of ArcGIS and Microsoft ® Excel. The manual is written for a single user but in many cases, some steps will be carried out by a biologist designing the survey and some steps will be carried out by a quantitative assistant. Thus, the manual essentially may be passed back and forth between these users. The SLL process primarily has been used to survey birds, and we refer to birds as subjects of the counts. The process, however, could be used to count any objects. ®
FDI based on Artificial Neural Network for Low-Voltage-Ride-Through in DFIG-based Wind Turbine.
Adouni, Amel; Chariag, Dhia; Diallo, Demba; Ben Hamed, Mouna; Sbita, Lassaâd
2016-09-01
As per modern electrical grid rules, Wind Turbine needs to operate continually even in presence severe grid faults as Low Voltage Ride Through (LVRT). Hence, a new LVRT Fault Detection and Identification (FDI) procedure has been developed to take the appropriate decision in order to develop the convenient control strategy. To obtain much better decision and enhanced FDI during grid fault, the proposed procedure is based on voltage indicators analysis using a new Artificial Neural Network architecture (ANN). In fact, two features are extracted (the amplitude and the angle phase). It is divided into two steps. The first is fault indicators generation and the second is indicators analysis for fault diagnosis. The first step is composed of six ANNs which are dedicated to describe the three phases of the grid (three amplitudes and three angle phases). Regarding to the second step, it is composed of a single ANN which analysis the indicators and generates a decision signal that describes the function mode (healthy or faulty). On other hand, the decision signal identifies the fault type. It allows distinguishing between the four faulty types. The diagnosis procedure is tested in simulation and experimental prototype. The obtained results confirm and approve its efficiency, rapidity, robustness and immunity to the noise and unknown inputs. Copyright © 2016 ISA. Published by Elsevier Ltd. All rights reserved.
Combating omission errors through task analysis and good reminders.
Reason, J
2002-03-01
Leaving out necessary task steps is the single most common human error type. Certain task steps possess characteristics that are more likely to provoke omissions than others, and can be identified in advance. The paper reports two studies. The first, involving a simple photocopier, established that failing to remove the last page of the original is the commonest omission. This step possesses four distinct error-provoking features that combine their effects in an additive fashion. The second study examined the degree to which everyday memory aids satisfy five features of a good reminder: conspicuity, contiguity, content, context, and countability. A close correspondence was found between the percentage use of strategies and the degree to which they satisfied these five criteria. A three stage omission management programme was outlined: task analysis (identifying discrete task steps) of some safety critical activity; assessing the omission likelihood of each step; and the choice and application of a suitable reminder. Such a programme is applicable to a variety of healthcare procedures.
Nishimura, Akinobu; Nakazora, Shigeto; Ito, Naoya; Fukuda, Aki; Kato, Ko; Sudo, Akihiro
2016-06-01
Traumatic dislocation of peroneal tendons in the ankle is an uncommon lesion that mainly affects young adults. Unfortunately, most cases lead to recurrent dislocation of the peroneal tendons of the ankle (RPTD). Therefore, most cases need operative treatment. One of the most common operative procedures is superior peroneal retinaculum (SPR) repair. Recently, surgery for RPTD has been achieved with less invasive arthroscopic procedures. In this article, tendoscopic surgery for RPTD using a double-row suture bridge technique is introduced. This technique consists of debridement of the lateral aspect of the fibula under an intrasheath pseudo-cavity, suture anchor insertion into the fibular ridge, and reattachment of the SPR to the fibula using a knotless anchor screwed into the lateral aspect of the fibula. This technique mimics the double-row suture bridge technique for rotator cuff tear repair. The double-row suture bridge technique requires more surgical steps than the single-row technique, but it provides a wider bone-SPR contact surface and tighter fixation than the single-row technique. This procedure is an attractive option because it is less invasive and has achieved results similar to open procedures.
Liu, Zhiyi; Zhang, Luyao; Liu, Yanling; Gu, Yang; Sun, Tieliang
2017-11-01
We aimed to evaluate the efficiency and safety of one-step procedure combined endoscopic retrograde cholangiopancreatography (ERCP) and laparoscopic cholecystectomy (LC) for treatment of patients with cholecysto-choledocholithiasis. A prospective randomized study was performed on 63 consecutive cholecysto-choledocholithiasis patients during 2008 and 2011. The efficiency and safety of one-step procedure was assessed by comparing the two-step LC with ERCP + endoscopic sphincterotomy (EST). Outcomes including intraoperative features, postoperative features (length of stay and postoperative complications) were evaluated. One- or two-step procedure of LC with ERCP + EST was successfully performed in all patients, and common bile duct stones were completely removed. Statistical analyses showed that length of stay and pulmonary infection rate were significantly lower in the test group compared with that in the control group (P < 0.05), whereas no statistical difference in other outcomes was found between the two groups (all P > 0.05). The one-step procedure of LC with ERCP + EST is superior to the two-step procedure for treatment of patients with cholecysto-choledocholithiasis regarding to the reduced hospital stay and inhibited occurrence of pulmonary infections. Compared with two-step procedure, one-step procedure of LC with ERCP + EST may be a superior option for cholecysto-choledocholithiasis patients treatment regarding to hospital stay and pulmonary infections.
A One-Step Delamination Procedure to Form Single Sheet Iron(III)-(oxy)Hydroxides
The dispersion of a layered iron(III)-(oxy)hydroxide intercalated with dodecanoate (oxGRC12, Fe3IIIO2.18(OH)3.13(C12H23O2)0.56(SO4)0.47; derived from the corr...
Specific arithmetic calculation deficits in children with Turner syndrome.
Rovet, J; Szekely, C; Hockenberry, M N
1994-12-01
Study 1 compared arithmetic processing skills on the WRAT-R in 45 girls with Turner syndrome (TS) and 92 age-matched female controls. Results revealed significant underachievement by subjects with TS, which reflected their poorer performance on problems requiring the retrieval of addition and multiplication facts and procedural knowledge for addition and division operations. TS subjects did not differ qualitatively from controls in type of procedural error committed. Study 2, which compared the performance of 10 subjects with TS and 31 controls on the Keymath Diagnostic Arithmetic Test, showed that the TS group had less adequate knowledge of arithmetic, subtraction, and multiplication procedures but did not differ from controls on Fact items. Error analyses revealed that TS subjects were more likely to confuse component steps or fail to separate intermediate steps or to complete problems. TS subjects relied to a greater degree on verbal than visual-spatial abilities in arithmetic processing while their visual-spatial abilities were associated with retrieval of simple multidigit addition facts and knowledge of subtraction, multiplication, and division procedures. Differences between the TS and control groups increased with age for Keymath, but not WRAT-R, procedures. Discrepant findings are related to the different task constraints (timed vs. untimed, single vs. alternate versions, size of item pool) and the use of different strategies (counting vs. fact retrieval). It is concluded that arithmetic difficulties in females with TS are due to less adequate procedural skills, combined with poorer fact retrieval in timed testing situations, rather than to inadequate visual-spatial abilities.
Recent technological advancements in laparoscopic surgical instruments
NASA Astrophysics Data System (ADS)
Subido, Edwin D. C.; Pacis, Danica Mitch M.; Bugtai, Nilo T.
2018-02-01
Laparoscopy was a progressive step to advancing surgical procedures as it minimised the scars left on the body after surgery, compared to traditional open surgery. Many years later, single-incision laparoscopic surgery (SILS) was created where, instead of having multiple incisions, only one incision is made or multiple small incisions in one location. SILS, or laparoendoscopic single-site surgery (LESS), may produce lesser scars but drawbacks for the surgeons are still present. This paper aims to present related literature of the recent technological developments in laparoscopic tools and procedure particularly in the vision system, handheld instruments. Tech advances in LESS will also be shown. Furthermore, this review intends to give an update on what has been going on in the surgical robot market and state which companies are interested and are developing robotic systems for commercial use to challenge Intuitive Surgical's da Vinci Surgical System that currently dominates the market.
Code Blue on Orbit: Treating Cardiac Arrest on the ISS
NASA Technical Reports Server (NTRS)
Bacal, Kira; Redmond, Melissa
2004-01-01
As a result of the Columbia tragedy on February 1,2003, the International Space Station (ISS) crew size has been temporarily reduced from three to two. This change forces adaptations in many operational procedures used by the crew, including medical protocols which were designed for scenarios involving one casualty and two caregivers. The Office of Space Medicine directed that the procedure for the resuscitation of a crewmember in cardiac arrest be rewritten for use by a single care provider. Methods: Adaptation of this procedure made use of current American Heart Association Advanced Cardiac Life Support (ACLS) procedures and reflects necessary compromises between the realities of the operational environment and prompt provision of medical care. Results: Numerous changes were incorporated due to the diminution in available personnel, including substitution of endotracheal rather than intravenous delivery of drugs, more rapid defibrillation, addition of a precordial thump, removal of transcutaneous pacing, streamlining of procedural steps, and clarification of termination criteria. Discussion: The on-orbit care available to the ISS crewmembers is constrained by numerous factors, including crew medical training, minimal medical assets, limited air/ground communication , and a single caregiver for the foreseeable future. All of these combine to make a successful resuscitation unlikely, however, this procedure must ultimately deal with not only the patient's welfare, but also that of the caregiver, the mission, and the program.
Student Opinions about the Seven-Step Procedure in Problem-Based Hospitality Management Education
ERIC Educational Resources Information Center
Zwaal, Wichard; Otting, Hans
2014-01-01
This study investigates how hospitality management students appreciate the role and application of the seven-step procedure in problem-based learning. A survey was developed containing sections about personal characteristics, recall of the seven steps, overall report marks, and 30 statements about the seven-step procedure. The survey was…
NASA Astrophysics Data System (ADS)
Heitkamp, Thomas; Deckers-Hebestreit, Gabriele; Börsch, Michael
2016-02-01
Adenosine triphosphate (ATP) is the universal chemical energy currency for cellular activities provided mainly by the membrane enzyme FoF1-ATP synthase in bacteria, chloroplasts and mitochondria. Synthesis of ATP is accompanied by subunit rotation within the enzyme. Over the past 15 years we have developed a variety of single-molecule FRET (smFRET) experiments to monitor catalytic action of individual bacterial enzymes in vitro. By specifically labeling rotating and static subunits within a single enzyme we were able to observe three-stepped rotation in the F1 motor, ten-stepped rotation in the Fo motor and transient elastic deformation of the connected rotor subunits. However, the spatial and temporal resolution of motor activities measured by smFRET were limited by the photophysics of the FRET fluorophores. Here we evaluate the novel FRET donor mNeonGreen as a fusion to FoF1-ATP synthase and compare it to the previously used fluorophore EGFP. Topics of this manuscript are the biochemical purification procedures and the activity measurements of the fully functional mutant enzyme.
Single-step colony assay for screening antibody libraries.
Kato, Mieko; Hanyu, Yoshiro
2017-08-10
We describe a method, single-step colony assay, for simple and rapid screening of single-chain Fv fragment (scFv) libraries. Colonies of Escherichia coli expressing the scFv library are formed on a hydrophilic filter that is positioned in contact with a membrane coated with an antigen. scFv expression is triggered upon treatment of colonies with an induction reagent, following which scFvs are secreted from the cells and diffused to the antigen-coated membrane. scFvs that exhibit binding affinity for the antigen are captured by the membrane-immobilized antigen. Lastly, detection of scFv binding of the antigen on the membrane allows identification of the clones on the filter that express antigen-specific scFvs. We tested this methodology by using an anti-rabbit IgG scFv, scFv(A10B), and a rat immune scFv library. Experiments conducted using scFv(A10B) revealed that this method improves scFv expression during the colony assay. By using our method to screen an immune library of 3×10 3 scFv clones, we established several clones exhibiting affinity for the antigen. Moreover, we tested 7 other antigens, including peptides, and successfully identified positive clones. We believe that this simple procedure and controlled scFv expression of the single-step colony assay could make the antibody screening both rapid and reliable and lead to successful isolation of positive clones from antibody libraries. Copyright © 2017 Elsevier B.V. All rights reserved.
Boudjemline, Younes
2018-01-01
To describe a new modification, the one-step procedure, that allows interventionists to pre-stent and implant a Melody valve simultaneously. Percutaneous pulmonary valve implantation (PPVI) is the standard of care for managing patients with dysfunctional right ventricular outflow tract, and the approach is standardized. Patients undergoing PPVI using the one-step procedure were identified in our database. Procedural data and radiation exposure were compared to those in a matched group of patients who underwent PPVI using the conventional two-step procedure. Between January 2016 and January 2017, PPVI was performed in 27 patients (median age/range, 19.1/10-55 years) using the one-step procedure involving manual crimping of one to three bare metal stents over the Melody valve. The stent and Melody valve were delivered successfully using the Ensemble delivery system. No complications occurred. All patients had excellent hemodynamic results (median/range post-PPVI right ventricular to pulmonary artery gradient, 9/0-20 mmHg). Valve function was excellent. Median procedural and fluoroscopic times were 56 and 10.2 min, respectively, which significantly differed from those of the two-step procedure group. Similarly, the dose area product (DAP), and radiation time were statistically lower in the one-step group than in the two-step group (P < 0.001 for all variables). After a median follow-up of 8 months (range, 3-14.7), no patient underwent reintervention, and no device dysfunction was observed. The one-step procedure is a safe modification that allows interventionists to prestent and implants the Melody valve simultaneously. It significantly reduces procedural and fluoroscopic times, and radiation exposure. © 2017 Wiley Periodicals, Inc.
AKAPS Act in a Two-Step Mechanism of Memory Acquisition
Scheunemann, Lisa; Skroblin, Philipp; Hundsrucker, Christian; Klussmann, Enno; Efetova, Marina
2013-01-01
Defining the molecular and neuronal basis of associative memories is based upon behavioral preparations that yield high performance due to selection of salient stimuli, strong reinforcement, and repeated conditioning trials. One of those preparations is the Drosophila aversive olfactory conditioning procedure where animals initiate multiple memory components after experience of a single cycle training procedure. Here, we explored the analysis of acquisition dynamics as a means to define memory components and revealed strong correlations between particular chronologies of shock impact and number experienced during the associative training situation and subsequent performance of conditioned avoidance. Analyzing acquisition dynamics in Drosophila memory mutants revealed that rutabaga (rut)-dependent cAMP signals couple in a divergent fashion for support of different memory components. In case of anesthesia-sensitive memory (ASM) we identified a characteristic two-step mechanism that links rut-AC1 to A-kinase anchoring proteins (AKAP)-sequestered protein kinase A at the level of Kenyon cells, a recognized center of olfactory learning within the fly brain. We propose that integration of rut-derived cAMP signals at level of AKAPs might serve as counting register that accounts for the two-step mechanism of ASM acquisition. PMID:24174675
Shin, S Y; Albert, J S; Mortman, R E
2009-12-01
To describe a case in which a mandibular right second premolar with a necrotic pulp, sinus tract, periradicular radiolucency and an immature apex underwent revascularization via a single treatment approach. Revascularization procedures have the potential to heal a partially necrotic pulp, which can be beneficial for the continued root development of immature teeth. However, it is not clear which revascularization protocols are the most effective. This case report details the outcome of a successful revascularization procedure on tooth 45 (FDI) in a 12-year-old patient, eliminating the associated periapical pathosis within 19 months. The tooth was treated using coronal root irrigation with 6% NaOCl and 2% chlorhexidine without instrumentation in a single visit. The successful outcome of this case report suggests that this conservative revascularization treatment approach can preserve the vitality of the dental pulp stem cells and create a suitable environment for pulp regeneration, resulting in the completion of root maturation. The noninstrumentation procedure using 6% NaOCl and 2% chlorhexidine coronal irrigation may help preserve the remaining vital dental pulp stem cells believed to be critical for pulp revascularization. A single visit pulp revascularization protocol can be a favourable treatment option for an immature permanent tooth with a partially necrotic pulp.
Pylorus preserving loop duodeno-enterostomy with sleeve gastrectomy - preliminary results
2014-01-01
Background Bariatric operations mostly combine a restrictive gastric component with a rerouting of the intestinal passage. The pylorus can thereby be alternatively preserved or excluded. With the aim of performing a “pylorus-preserving gastric bypass”, we present early results of a proximal postpyloric loop duodeno-jejunostomy associated with a sleeve gastrectomy (LSG) compared to results of a parallel, but distal LSG with a loop duodeno-ileostomy as a two-step procedure. Methods 16 patients underwent either a two-step LSG with a distal loop duodeno-ileostomy (DIOS) as revisional bariatric surgery or a combined single step operation with a proximal duodeno-jejunostomy (DJOS). Total small intestinal length was determined to account for inter-individual differences. Results Mean operative time for the second-step of the DIOS operation was 121 min and 147 min for the combined DJOS operation. The overall intestinal length was 750.8 cm (range 600-900 cm) with a bypassed limb length of 235.7 cm in DJOS patients. The mean length of the common channel in DIOS patients measured 245.6 cm. Overall excess weight loss (%EWL) of the two-step DIOS procedure came to 38.31% and 49.60%, DJOS patients experienced an %EWL of 19.75% and 46.53% at 1 and 6 months, resp. No complication related to the duodeno-enterostomy occurred. Conclusions Loop duodeno-enterosomies with sleeve gastrectomy can be safely performed and may open new alternatives in bariatric surgery with the possibility for inter-individual adaptation. PMID:24725654
Three-step HPLC-ESI-MS/MS procedure for screening and identifying non-target flavonoid derivatives
NASA Astrophysics Data System (ADS)
Rak, Gábor; Fodor, Péter; Abrankó, László
2010-02-01
A three-step HPLC-ESI-MS/MS procedure is designed for screening and identification of non-target flavonoid derivatives of selected flavonoid aglycones. In this method the five commonly appearing aglycones (apigenin, luteolin, myricetin, naringenin and quercetin) were selected. The method consists of three individual mass spectrometric experiments of which the first two were implemented within a single chromatographic acquisition. The third step was carried out during a replicate chromatographic run using the same RP-HPLC conditions. The first step, a multiple reaction monitoring (MRM) scan of the aglycones was performed to define the number of derivatives relating to the selected aglycones. For this purpose the characteristic aglycone parts of the unknowns were used as specific tags of the molecules, which were generated as in-source fragments. Secondly, a full scan MS experiment is performed to identify the masses of the potential derivatives of the selected aglycones. Finally, the third step had the capability to confirm the supposed derivatives. The developed method was applied to a commercially available black currant juice to demonstrate its capability to detect and identify various flavonoid glycosides without any preliminary information about their presence in the sample. As a result 13 compounds were detected and identified in total. Namely, 3 different myricetin glycosides and the myricetin aglycone 2 luteolin glycosides plus the aglycone and 3 quercetin glycosides plus the aglycone could be identified from the tested black currant sample. In the case of apigenin and naringenin only the aglycones could be detected.
Budzyńska, Agnieszka; Nowakowska-Duława, Ewa; Marek, Tomasz; Hartleb, Marek
2016-10-01
Most patients with malignant biliary obstruction are suited only for palliation by endoscopic drainage with plastic stents (PS) or self-expandable metal stents (SEMS). To compare the clinical outcome and costs of biliary stenting with SEMS and PS in patients with malignant biliary strictures. A total of 114 patients with malignant jaundice who underwent 376 endoscopic retrograde biliary drainage (ERBD) were studied. ERBD with the placement of PS was performed in 80 patients, with one-step SEMS in 20 patients and two-step SEMS in 14 patients. Significantly fewer ERBD interventions were performed in patients with one-step SEMS than PS or the two-step SEMS technique (2.0±1.12 vs. 3.1±1.7 or 5.7±2.1, respectively, P<0.0001). The median hospitalization duration per procedure was similar for the three groups of patients. The patients' survival time was the longest in the two-step SEMS group in comparison with the one-step SEMS and PS groups (596±270 vs. 276±141 or 208±219 days, P<0.001). Overall median time to recurrent biliary obstruction was 89.3±159 days for PS and 120.6±101 days for SEMS (P=0.01). The total cost of hospitalization with ERBD was higher for two-step SEMS than for one-step SEMS or PS (1448±312, 1152±135 and 977±156&OV0556;, P<0.0001). However, the estimated annual cost of medical care for one-step SEMS was higher than that for the two-step SEMS or PS groups (4618, 4079, and 3995&OV0556;, respectively). Biliary decompression by SEMS is associated with longer patency and reduced number of auxiliary procedures; however, repeated PS insertions still remain the most cost-effective strategy.
Real-Time Gait Cycle Parameter Recognition Using a Wearable Accelerometry System
Yang, Che-Chang; Hsu, Yeh-Liang; Shih, Kao-Shang; Lu, Jun-Ming
2011-01-01
This paper presents the development of a wearable accelerometry system for real-time gait cycle parameter recognition. Using a tri-axial accelerometer, the wearable motion detector is a single waist-mounted device to measure trunk accelerations during walking. Several gait cycle parameters, including cadence, step regularity, stride regularity and step symmetry can be estimated in real-time by using autocorrelation procedure. For validation purposes, five Parkinson’s disease (PD) patients and five young healthy adults were recruited in an experiment. The gait cycle parameters among the two subject groups of different mobility can be quantified and distinguished by the system. Practical considerations and limitations for implementing the autocorrelation procedure in such a real-time system are also discussed. This study can be extended to the future attempts in real-time detection of disabling gaits, such as festinating or freezing of gait in PD patients. Ambulatory rehabilitation, gait assessment and personal telecare for people with gait disorders are also possible applications. PMID:22164019
Polyethylene Ear Reconstruction: A State-of-the-Art Surgical Journey.
Reinisch, John; Tahiri, Youssef
2018-02-01
The use of a porous high-density polyethylene implant for ear reconstruction is gradually gaining acceptance because it allows for a pleasing ear reconstruction in young children before they enter school. In response to this growing interest, the authors decided to write an article clarifying in detail all the steps of this challenging procedure. In this article, the authors also answer all the common questions that surgeons have when they come to observe the operation, or when they go back to their respective practices and start performing this procedure. The authors describe in detail the operative steps that allow for a successful ear reconstruction using porous high-density polyethylene. The key parts of this operation are to meticulously harvest a well-vascularized superficial temporoparietal fascia flap and to use appropriate color-matched skin grafts. This method allows for a pleasing ear reconstruction with excellent definition, projection, symmetry, and long-term viability. The use of porous high-density polyethylene with a thin superficial temporoparietal fascia flap coverage is the authors' preferred method of ear reconstruction because it can be performed at an earlier age, in a single stage, as an outpatient procedure, and with minimal discomfort and psychological trauma for the patients and parents.
Whole-genome multiple displacement amplification from single cells.
Spits, Claudia; Le Caignec, Cédric; De Rycke, Martine; Van Haute, Lindsey; Van Steirteghem, André; Liebaers, Inge; Sermon, Karen
2006-01-01
Multiple displacement amplification (MDA) is a recently described method of whole-genome amplification (WGA) that has proven efficient in the amplification of small amounts of DNA, including DNA from single cells. Compared with PCR-based WGA methods, MDA generates DNA with a higher molecular weight and shows better genome coverage. This protocol was developed for preimplantation genetic diagnosis, and details a method for performing single-cell MDA using the phi29 DNA polymerase. It can also be useful for the amplification of other minute quantities of DNA, such as from forensic material or microdissected tissue. The protocol includes the collection and lysis of single cells, and all materials and steps involved in the MDA reaction. The whole procedure takes 3 h and generates 1-2 microg of DNA from a single cell, which is suitable for multiple downstream applications, such as sequencing, short tandem repeat analysis or array comparative genomic hybridization.
Performance of the Seven-Step Procedure in Problem-Based Hospitality Management Education
ERIC Educational Resources Information Center
Zwaal, Wichard; Otting, Hans
2016-01-01
The study focuses on the seven-step procedure (SSP) in problem-based learning (PBL). The way students apply the seven-step procedure will help us understand how students work in a problem-based learning curriculum. So far, little is known about how students rate the performance and importance of the different steps, the amount of time they spend…
Purification of Proteins Fused to Maltose-Binding Protein.
Lebendiker, Mario; Danieli, Tsafi
2017-01-01
Maltose-Binding Protein (MBP) is one of the most popular fusion partners being used for producing recombinant proteins in bacterial cells. MBP allows the use of a simple capture affinity step on Amylose-Agarose or Dextrin-Sepharose columns, resulting in a protein that is often 70-90 % pure in a single step. In addition to protein isolation applications, MBP provides a high degree of translation, and facilitates the proper folding and solubility of the target protein. This paper describes efficient procedures for isolating highly purified MBP target proteins. Special attention is given to considerations for downstream applications such as structural determination studies, protein activity assays, and assessing the chemical characteristics of the target protein.
One-step formation and sterilization of gellan and hyaluronan nanohydrogels using autoclave.
Montanari, Elita; De Rugeriis, Maria Cristina; Di Meo, Chiara; Censi, Roberta; Coviello, Tommasina; Alhaique, Franco; Matricardi, Pietro
2015-01-01
The sterilization of nanoparticles for biomedical applications is one of the challenges that must be faced in the development of nanoparticulate systems. Usually, autoclave sterilization cannot be applied because of stability concerns when polymeric nanoparticles are involved. This paper describes an innovative method which allows to obtain, using a single step autoclave procedure, the preparation and, at the same time, the sterilization of self-assembling nanohydrogels (NHs) obtained with cholesterol-derivatized gellan and hyaluronic acid. Moreover, by using this approach, NHs, while formed in the autoclave, can be easily loaded with drugs. The obtained NHs dispersion can be lyophilized in the presence of a cryoprotectant, leading to the original NHs after re-dispersion in water.
Arnold, Markus P; Duthon, Victoria; Neyret, Philippe; Hirschmann, Michael T
2013-02-01
The present paper describes the rationale behind the surgical technique and the clinical results of the iso-anatomical, single bundle bone patellar-tendon bone anterior cruciate ligament (ACL) reconstruction. Using a second incision on the distal lateral femur an outside-in femoral tunnel is drilled. Guided by a special aiming device it is possible to place the femoral tunnel in the centre of the ACL footprint in every single case. Since every crucial step of the procedure is under visual control, the technique is safe and reliable, which is mirrored by good clinical results.
Coulomb explosion: a novel approach to separate single-walled carbon nanotubes from their bundle.
Liu, Guangtong; Zhao, Yuanchun; Zheng, Kaihong; Liu, Zheng; Ma, Wenjun; Ren, Yan; Xie, Sishen; Sun, Lianfeng
2009-01-01
A novel approach based on Coulomb explosion has been developed to separate single-walled carbon nanotubes (SWNTs) from their bundle. With this technique, we can readily separate a bundle of SWNTs into smaller bundles with uniform diameter as well as some individual SWNTs. The separated SWNTs have a typical length of several microns and form a nanotree at one end of the original bundle. More importantly, this separating procedure involves no surfactant and includes only one-step physical process. The separation method offers great conveniences for the subsequent individual SWNT or multiterminal SWNTs device fabrication and their physical properties studies.
Teaching single-incision laparoscopic appendectomy in pediatric patients.
Burjonrappa, Sathyaprasad C; Nerkar, Hrishikesh
2012-01-01
Laparoscopic appendectomy is accepted as the gold standard technique for the treatment of acute appendicitis. Recently single-incision laparoscopic surgery (SILS) was tried in the pediatric population and was shown to be both feasible and safe. We describe our early experience in teaching the SILS procedure for appendicitis in a large community hospital center surgical residency program. SILS appendectomy was performed in 40 consecutive patients with acute appendicitis who were admitted by a single surgeon from May 2011 to August 2011. All patients over the age of 4 y presenting with noncomplicated and complicated appendicitis (perforated) were offered SILS appendectomy. Execution of the technical aspects of 20 SILS operations done by 3 PGY III residents was evaluated. The average age of the patient was 11.1 y (range, 7 to 15). SILS was performed successfully in 19 out of 20 patients. Nineteen patients underwent emergent or urgent appendectomy, while 1 patient underwent an interval procedure. Nine patients were found to have perforated appendicitis, while the other 11 had noncomplicated acute appendicitis. One patient was converted to conventional 3-port laparoscopy due to difficulties during the procedure. The mean operative time was 73 min (range, 47 to 112). A significant learning curve to successfully execute the critical steps of the SILS procedure was noted in all residents evaluated. SILS technology appears promising for the treatment of acute appendicitis. However, its successful incorporation into surgical training programs will depend on the development of innovative simulation strategies.
Arkhipova, Viktoriya V; Apyari, Vladimir V; Dmitrienko, Stanislava G
2015-03-15
Desensitized ionene-stabilized gold nanoparticles have been prepared and applied as a colorimetric probe for the single-step test for sulfate ions at the relatively high concentration level. The approach is based on aggregation of the nanoparticles leading to the change in absorption spectra and color of the solution. These nanoparticles are characterized by the decreased sensitivity due to both electrostatic and steric stabilization, which allows for simple, and rapid direct single-step determination of sulfate at the relatively high concentration level in real water samples without sample pretreatment or dilution. Influence of different factors (the time of interaction, pH, the concentrations of sulfate ions and the nanoparticles) on the aggregation and analytical performance of the procedure was investigated. The method allows for the determination of sulfate ions in the mass range of 0.2-0.4 mg with RSD of 5% from the sample volume of less than 2 mL. It has a sharp dependence of the colorimetric response on the concentration of sulfate, which makes it prospective for indicating deviations of the sulfate concentration regarding some declared value chosen within the above range. The time of the analysis is 2 min. The method was applied to the analysis of mineral water samples. Copyright © 2014 Elsevier B.V. All rights reserved.
Single Port Laparoscopic Gastrostomy: description of a technique and initial experience.
Palermo, Mariano; Domínguez, Mario Luis; Acquafresca, Pablo; Duza, Guillermo; Giménez, Mariano
2015-12-01
Since the first classic descriptions of surgical gastrostomies for feeding by supra-umbilical medial incisions, patients were operated under general anesthesia, with prolonged time of surgery; these were patients in poor health status, undernourished due to inadequate intake or to neurological or tumor involvement, with prolonged hospitalization, both for the recovery of the intestinal motility as well as for the recovery of post-surgical wounds. Therefore, we describe a new minimally invasive technique as an alternative to the percutaneous or endoscopic gastrostomy, in patients where we are not allowed to place a nasogastric tube to insufflate the stomach. This is mostly seen in patients with tumors, which cause obstruction. Between July 2012 and June 2013, 8 patients underwent a single port laparoscopic gastrostomy. Five were females, mean age: 77 years (range: 67-87). In all the patients, it was impossible to place a nasogastric tube, due to obstructive tumor. The mean time of the procedure was 45 minutes. Seven patients underwent tolerance of dextrose 10% through the catheter after 12 hours and one 24 hours after the procedures. Enteral feeding was indicated after the dextrose 10% tolerance was performed. No complications related to the procedure were observed. Currently, the gold standard technique to perform a gastrostomy is the percutaneous or endoscopic approach. In patients with head and neck tumors, when it is not possible to insert a nasogastric tube to insufflate the stomach, a laparoscopic gastrostomy would be indicated. We describe a new technique, step by step, to perform less invasive laparoscopic surgery by a single port laparoscopic gastrostomy. The diameter created is the same as the one performed with an open technique, but in this case, with a minimally invasive approach, that allows us to start feeding the patient with a high quality of feeding, because of the wider lumen.
NASA Technical Reports Server (NTRS)
Barrett, J. E.; Wells, D. C.; Conrad, G. W.
1999-01-01
Pretreatment methods were used to improve neurofilament immunostaining in corneas from embryonic day 16 Japanese quail corneas that had been stored in fixative solution for several months. A sequential combination of the following three pretreatments: brief microwave heating in saline, followed by extraction with sodium dodecyl sulfate (SDS) at 37 degrees C, followed by digestion with hyaluronidase at 37 degrees C, produced significantly increased antibody staining of corneal neurofilament proteins, compared with embryonic corneas subjected to no prior pretreatments or to single or two-step protocols. After applying the sequence of all three pretreatments, darkest nerve staining and increased numbers of fine branches were observed, together with lower background staining. Thus, the result of applying the three-step pretreatment sequence is better than that of applying any of its component single pretreatments or even combinations of any two of them. These findings therefore suggest that each of these three pretreatments causes a unique effect, beneficial to immunostaining of neurofilament proteins, and that their individual effects are independent and additive. In addition to embryonic corneas, the three-step procedure also may be useful for immunostaining of nerves in other very delicate, highly-hydrated tissues containing an abundance of extracellular matrix.
Hansen, Dominique; Jacobs, Nele; Thijs, Herbert; Dendale, Paul; Claes, Neree
2016-09-01
Healthcare professionals with limited access to ergospirometry remain in need of valid and simple submaximal exercise tests to predict maximal oxygen uptake (VO2max ). Despite previous validation studies concerning fixed-rate step tests, accurate equations for the estimation of VO2max remain to be formulated from a large sample of healthy adults between age 18-75 years (n > 100). The aim of this study was to develop a valid equation to estimate VO2max from a fixed-rate step test in a larger sample of healthy adults. A maximal ergospirometry test, with assessment of cardiopulmonary parameters and VO2max , and a 5-min fixed-rate single-stage step test were executed in 112 healthy adults (age 18-75 years). During the step test and subsequent recovery, heart rate was monitored continuously. By linear regression analysis, an equation to predict VO2max from the step test was formulated. This equation was assessed for level of agreement by displaying Bland-Altman plots and calculation of intraclass correlations with measured VO2max . Validity further was assessed by employing a Jackknife procedure. The linear regression analysis generated the following equation to predict VO2max (l min(-1) ) from the step test: 0·054(BMI)+0·612(gender)+3·359(body height in m)+0·019(fitness index)-0·012(HRmax)-0·011(age)-3·475. This equation explained 78% of the variance in measured VO2max (F = 66·15, P<0·001). The level of agreement and intraclass correlation was high (ICC = 0·94, P<0·001) between measured and predicted VO2max . From this study, a valid fixed-rate single-stage step test equation has been developed to estimate VO2max in healthy adults. This tool could be employed by healthcare professionals with limited access to ergospirometry. © 2015 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.
Calibration Procedures on Oblique Camera Setups
NASA Astrophysics Data System (ADS)
Kemper, G.; Melykuti, B.; Yu, C.
2016-06-01
Beside the creation of virtual animated 3D City models, analysis for homeland security and city planning, the accurately determination of geometric features out of oblique imagery is an important task today. Due to the huge number of single images the reduction of control points force to make use of direct referencing devices. This causes a precise camera-calibration and additional adjustment procedures. This paper aims to show the workflow of the various calibration steps and will present examples of the calibration flight with the final 3D City model. In difference to most other software, the oblique cameras are used not as co-registered sensors in relation to the nadir one, all camera images enter the AT process as single pre-oriented data. This enables a better post calibration in order to detect variations in the single camera calibration and other mechanical effects. The shown sensor (Oblique Imager) is based o 5 Phase One cameras were the nadir one has 80 MPIX equipped with a 50 mm lens while the oblique ones capture images with 50 MPix using 80 mm lenses. The cameras are mounted robust inside a housing to protect this against physical and thermal deformations. The sensor head hosts also an IMU which is connected to a POS AV GNSS Receiver. The sensor is stabilized by a gyro-mount which creates floating Antenna -IMU lever arms. They had to be registered together with the Raw GNSS-IMU Data. The camera calibration procedure was performed based on a special calibration flight with 351 shoots of all 5 cameras and registered the GPS/IMU data. This specific mission was designed in two different altitudes with additional cross lines on each flying heights. The five images from each exposure positions have no overlaps but in the block there are many overlaps resulting in up to 200 measurements per points. On each photo there were in average 110 well distributed measured points which is a satisfying number for the camera calibration. In a first step with the help of the nadir camera and the GPS/IMU data, an initial orientation correction and radial correction were calculated. With this approach, the whole project was calculated and calibrated in one step. During the iteration process the radial and tangential parameters were switched on individually for the camera heads and after that the camera constants and principal point positions were checked and finally calibrated. Besides that, the bore side calibration can be performed either on basis of the nadir camera and their offsets, or independently for each camera without correlation to the others. This must be performed in a complete mission anyway to get stability between the single camera heads. Determining the lever arms of the nodal-points to the IMU centre needs more caution than for a single camera especially due to the strong tilt angle. Prepared all these previous steps, you get a highly accurate sensor that enables a fully automated data extraction with a rapid update of you existing data. Frequently monitoring urban dynamics is then possible in fully 3D environment.
Radial access for cerebrovascular procedures: Case report and technical note.
Satti, Sudhakar R; Vance, Ansar Z; Sivapatham, Thinesh
2016-04-01
Advantages of radial access over brachial/axillary or femoral access have been well described for several decades and include decreased cost, patient preference, and decreased major access site complications. Despite these advantages, radial access is rarely employed or even considered for neurointerventional procedures. This attitude should be reconsidered given several recent large, randomized, controlled trials from the cardiovascular literature proving that radial access is associated with statistically lower costs, decreased incidence of myocardial infarctions, strokes, and even decreased mortality. Radial access is now considered the standard of care for percutaneous coronary interventions in most US centers. Although radial access has been described for neurovascular procedures in the past, overall experience is limited. The two major challenges are the unique anatomy required to access the cerebral vasculature given very acute angles between the arm and craniocervical vessels and limitations in available technology. We present a simplified approach to radial access for cerebrovascular procedures and provide a concise step-by-step approach for patient selection, ultrasound-guided single-wall access, recommended catheters/wires, and review of patent hemostasis. Additionally, we present a complex cerebrovascular intervention in which standard femoral access was unsuccessful, while radial access was quickly achieved to highlight the importance of familiarity with the radial approach for all neurointerventionalists. We have found that the learning curve is not too steep and that the radial access approach can be adopted smoothly for a large percentage of diagnostic and interventional neuroradiologic procedures. Radial access should be considered in all patients undergoing a cerebrovascular procedure. © The Author(s) 2015.
Steepest descent method implementation on unconstrained optimization problem using C++ program
NASA Astrophysics Data System (ADS)
Napitupulu, H.; Sukono; Mohd, I. Bin; Hidayat, Y.; Supian, S.
2018-03-01
Steepest Descent is known as the simplest gradient method. Recently, many researches are done to obtain the appropriate step size in order to reduce the objective function value progressively. In this paper, the properties of steepest descent method from literatures are reviewed together with advantages and disadvantages of each step size procedure. The development of steepest descent method due to its step size procedure is discussed. In order to test the performance of each step size, we run a steepest descent procedure in C++ program. We implemented it to unconstrained optimization test problem with two variables, then we compare the numerical results of each step size procedure. Based on the numerical experiment, we conclude the general computational features and weaknesses of each procedure in each case of problem.
Complete supine percutaneous nephrolithotomy with GoPro®. Ten steps for success.
Vicentini, Fabio Carvalho; Dos Santos, Hugo Daniel Barone; Batagello, Carlos Alfredo; Amundson, Julia Rothe; Oliveira, Evaristo Peixoto; Marchini, Giovanni Scala; Srougi, Miguel; Nahas, Willian Carlos; Mazzucchi, Eduardo
2018-03-15
To show a video of a complete supine Percutaneous Nephrolithotomy (csPCNL) performed for the treatment of a staghorn calculus, from the surgeon's point of view. The procedure was recorded with a GoPro® camera, demonstrating the ten essential steps for a successful procedure. The patient was a 38 years-old woman with 2.4cm of left kidney lower pole stone burden who presented with 3 months of lumbar pain and recurrent urinary tract infections. She had a previous diagnosis of polycystic kidney disease and chronic renal failure stage 2. CT scan showed two 1.2cm stones in the lower pole (Guy's Stone Score 2). She had a previous ipsilateral double J insertion due to an obstructive pyelonephritis. The csPCNL was uneventful with a single access in the lower pole. The surgeon had a Full HD GoPro Hero 4 Session® camera mounted on his head, controlled by the surgical team with a remote control. All of the mains steps were recorded. Informed consent was obtained prior to the procedure. The surgical time was 90 minutes. Hemoglobin drop was 0.5g/dL. A post-operative CT scan was stone-free. The patient was discharged 36 hours after surgery. The camera worked properly and didn't cause pain or muscle discomfort to the surgeon. The quality of the recorded movie was excellent. GoPro® camera proved to be a very interesting tool to document surgeries without interfering with the procedure and with great educational potential. More studies should be conducted to evaluate the role of this equipment. Copyright® by the International Brazilian Journal of Urology.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ko, Young Ho; Han, Myoung Soo; Han, Jong Man
2007-05-17
Doubly curved thick plate forming in shipbuilding industries is currently performed by a thermal forming process, called as Line Heating by using gas flame torches. Due to the empirical manual work of it, the industries are eager for an alternative way to manufacture curved thick plates for ships. It was envisaged in this study to manufacture doubly curved thick plates by the multi-punch die forming. Experiments and finite element analyses were conducted to evaluate the feasibility of the reconfigurable discrete die forming to the thick plates. Single and segmented multiple step forming procedures were considered from both forming efficiency andmore » accuracy. Configuration of the multi-punch dies suitable for the segmented multiple step forming was also explored. As a result, Segmented multiple step forming with matched dies had a limited formability when the objective shapes become complicate, while a unmatched die configuration provided better possibility to manufacture large curved plates for ships.« less
NASA Astrophysics Data System (ADS)
Velmiskin, Vladimir V.; Egorova, Olga N.; Mishkin, Vladimir; Nishchev, Konstantin; Semjonov, Sergey L.
2012-04-01
A procedure for the preparation of optically homogeneous glass for fiber preforms through sintering of coarse oxide particles and further processing of the resultant glass, including several drawing and stacking steps, is described. Reducing the pressure to 10-2 Torr during sintering considerably reduced the amount of gas bubbles in Yb/Al-doped silica glass and decreased the background loss to 100 dB/km after the third drawing-stacking-consolidation cycle. For comparison, a fiber singly doped with alumina was fabricated by the same procedure as above. The level of wavelength- independent losses in that fiber was 65 dB/km.
Old and New Techniques as a Safe Hybrid Approach for Carotid Tandem Lesions.
Barillà, David; Massara, Mafalda; Alberti, Antonino; Volpe, Alberto; Cutrupi, Andrea; Versace, Paolo; Volpe, Pietro
2016-04-01
Carotid revascularization is performed to prevent stroke. Carotid tandem lesions represent a challenge for treatment, and a hybrid approach may result effective. A high-risk 65-year-old woman presented with a "tandem lesion" of left common and internal carotid artery. She was deemed unfit for "simple" standard carotid endarterectomy (CEA). A "single-step" safe hybrid procedure was scheduled for the patient. A "Cormier" carotid vein graft bypass with a retrograde stenting was performed under local anesthesia. The "safe hybrid procedure" for tandem lesions of the common and internal carotid artery is effective and suitable in high-risk patients in a high-volume centers. Copyright © 2016 Elsevier Inc. All rights reserved.
Protein complex purification from Thermoplasma acidophilum using a phage display library.
Hubert, Agnes; Mitani, Yasuo; Tamura, Tomohiro; Boicu, Marius; Nagy, István
2014-03-01
We developed a novel protein complex isolation method using a single-chain variable fragment (scFv) based phage display library in a two-step purification procedure. We adapted the antibody-based phage display technology which has been developed for single target proteins to a protein mixture containing about 300 proteins, mostly subunits of Thermoplasma acidophilum complexes. T. acidophilum protein specific phages were selected and corresponding scFvs were expressed in Escherichia coli. E. coli cell lysate containing the expressed His-tagged scFv specific against one antigen protein and T. acidophilum crude cell lysate containing intact target protein complexes were mixed, incubated and subjected to protein purification using affinity and size exclusion chromatography steps. This method was confirmed to isolate intact particles of thermosome and proteasome suitable for electron microscopy analysis and provides a novel protein complex isolation strategy applicable to organisms where no genetic tools are available. Copyright © 2013 Elsevier B.V. All rights reserved.
Considering dominance in reduced single-step genomic evaluations.
Ertl, J; Edel, C; Pimentel, E C G; Emmerling, R; Götz, K-U
2018-06-01
Single-step models including dominance can be an enormous computational task and can even be prohibitive for practical application. In this study, we try to answer the question whether a reduced single-step model is able to estimate breeding values of bulls and breeding values, dominance deviations and total genetic values of cows with acceptable quality. Genetic values and phenotypes were simulated (500 repetitions) for a small Fleckvieh pedigree consisting of 371 bulls (180 thereof genotyped) and 553 cows (40 thereof genotyped). This pedigree was virtually extended for 2,407 non-genotyped daughters. Genetic values were estimated with the single-step model and with different reduced single-step models. Including more relatives of genotyped cows in the reduced single-step model resulted in a better agreement of results with the single-step model. Accuracies of genetic values were largest with single-step and smallest with reduced single-step when only the cows genotyped were modelled. The results indicate that a reduced single-step model is suitable to estimate breeding values of bulls and breeding values, dominance deviations and total genetic values of cows with acceptable quality. © 2018 Blackwell Verlag GmbH.
Porous single-phase NiTi processed under Ca reducing vapor for use as a bone graft substitute.
Bertheville, Bernard
2006-03-01
Porous nickel-titanium alloys (NiTi, nitinol) have recently attracted attention in clinical surgery because they are a very interesting alternative to the more brittle and less machinable conventional porous Ca-based ceramics. The main remaining limitations come from the chemical homogeneity of the as-processed porous nickel-titanium alloys, which always contain undesired secondary Ti- and Ni-rich phases. These are known to weaken the NiTi products, to favor their cavitation corrosion and to decrease their biocompatibility. Elemental nickel must also be avoided because it could give rise to several adverse tissue reactions. Therefore, the synthesis of porous single-phase NiTi alloys by using a basic single-step sintering procedure is an important step towards the processing of safe implant materials. The sintering process used in this work is based on a vapor phase calciothermic reduction operating during the NiTi compound formation. The as-processed porous nickel-titanium microstructure is single-phase and shows a uniformly open pore distribution with porosity of about 53% and pore diameters in the range 20-100 microm. Furthermore, due to the process, fine CaO layers grow on the NiTi outer and inner surfaces, acting as possible promoting agents for the ingrowth of bone cells at the implantation site.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ma, S. G.; Zhang, S. F.; Gao, M. C.
2013-08-22
For the first time, a face-centered-cubic, single-crystal CoCrFeNiAl{sub 0.3} (designated as Al0.3), high-entropy alloy (HEA) was successfully synthesized by the Bridgman solidification (BS) method, at an extremely low withdrawal velocity through a constant temperature gradient, for which it underwent two BS steps. Specially, at the first BS step, the alloy sample underwent several morphological transitions accompanying the crystal growth from the melt. This microstructure evolves from as-cast dendrites, to equiaxed grains, and then to columnar crystals, and last to the single crystal. In particular, at the equiaxed-grain region, some visible annealing twins were observed, which indicates a low stacking faultmore » energy of the Al0.3 alloy. Although a body-centered- cubic CoCrFeNiAl (Al1) HEA was also prepared under the same conditions, only a single columnar-crystal structure with instinctively preferential crystallographic orientations was obtained by the same procedure. A similar morphological transition from dendrites to equiaxed grains occurred at the equiaxed-grain region in Al1 alloy, but the annealing twins were not observed probably because a higher Al addition leads to a higher stacking fault energy for this alloy.« less
Methods for Isolation, Purification, and Propagation of Bacteriophages of Campylobacter jejuni.
Gencay, Yilmaz Emre; Birk, Tina; Sørensen, Martine Camilla Holst; Brøndsted, Lone
2017-01-01
Here, we describe the methods for isolation, purification, and propagation of Campylobacter jejuni bacteriophages from samples expected to contain high number of phages such as chicken feces. The overall steps are (1) liberation of phages from the sample material; (2) observation of plaque-forming units on C. jejuni lawns using a spot assay; (3) isolation of single plaques; (4) consecutive purification procedures; and (5) propagation of purified phages from a plate lysate to prepare master stocks.
Pal, Jayanta K; Berwal, Sunil K; Soni, Rupali N
2012-01-01
A simple method for staining of proteins simultaneously on sodium dodecyl sulfate (SDS) polyacrylamide gels and nitrocellulose membranes by Alta during western blot analysis is described. A 5% solution of Alta, a commercially available cosmetic preparation, is added in the upper tank buffer during electrophoresis. On completion of electrophoresis, the gel is washed in distilled water and viewed on a white light plate and a transilluminator to photograph the protein profiles. The gel is processed for western blot transfer of proteins onto a nitrocellulose membrane, and upon completion, the protein profiles on the membrane are viewed and photographed as stated above. The membrane can then be processed for immunostaining as per the standard procedure. Thus, the staining procedure using Alta is simple, rapid (without any need of destaining), and cost-effective.
Kloß, Sandra; Lorenz, Björn; Dees, Stefan; Labugger, Ines; Rösch, Petra; Popp, Jürgen
2015-11-01
Lower respiratory tract infections are the fourth leading cause of death worldwide. Here, a timely identification of the causing pathogens is crucial to the success of the treatment. Raman spectroscopy allows for quick identification of bacterial cells without the need for time-consuming cultivation steps, which is the current gold standard to detect pathogens. However, before Raman spectroscopy can be used to identify pathogens, they have to be isolated from the sample matrix, i.e., sputum in case of lower respiratory tract infections. In this study, we report an isolation protocol for single bacterial cells from sputum samples for Raman spectroscopic identification. Prior to the isolation, a liquefaction step using the proteolytic enzyme mixture Pronase E is required in order to deal with the high viscosity of sputum. The extraction of the bacteria was subsequently performed via different filtration and centrifugation steps, whereby isolation ratios between 46 and 57 % were achieved for sputa spiked with 6·10(7) to 6·10(4) CFU/mL of Staphylococcus aureus. The compatibility of such a liquefaction and isolation procedure towards a Raman spectroscopic classification was shown for five different model species, namely S. aureus, Staphylococcus epidermidis, Streptococcus pneumoniae, Klebsiella pneumoniae, and Pseudomonas aeruginosa. A classification of single-cell Raman spectra of these five species with an accuracy of 98.5 % could be achieved on the basis of a principal component analysis (PCA) followed by a linear discriminant analysis (LDA). These classification results could be validated with an independent test dataset, where 97.4 % of all spectra were identified correctly. Graphical Abstract Development of an isolation protocol of bacterial cells out of sputum samples followed by Raman spectroscopic measurement and species identification using chemometrical models.
Procedural key steps in laparoscopic colorectal surgery, consensus through Delphi methodology.
Dijkstra, Frederieke A; Bosker, Robbert J I; Veeger, Nicolaas J G M; van Det, Marc J; Pierie, Jean Pierre E N
2015-09-01
While several procedural training curricula in laparoscopic colorectal surgery have been validated and published, none have focused on dividing surgical procedures into well-identified segments, which can be trained and assessed separately. This enables the surgeon and resident to focus on a specific segment, or combination of segments, of a procedure. Furthermore, it will provide a consistent and uniform method of training for residents rotating through different teaching hospitals. The goal of this study was to determine consensus on the key steps of laparoscopic right hemicolectomy and laparoscopic sigmoid colectomy among experts in our University Medical Center and affiliated hospitals. This will form the basis for the INVEST video-assisted side-by-side training curriculum. The Delphi method was used for determining consensus on key steps of both procedures. A list of 31 steps for laparoscopic right hemicolectomy and 37 steps for laparoscopic sigmoid colectomy was compiled from textbooks and national and international guidelines. In an online questionnaire, 22 experts in 12 hospitals within our teaching region were invited to rate all steps on a Likert scale on importance for the procedure. Consensus was reached in two rounds. Sixteen experts agreed to participate. Of these 16 experts, 14 (88%) completed the questionnaire for both procedures. Of the 14 who completed the first round, 13 (93%) completed the second round. Cronbach's alpha was 0.79 for the right hemicolectomy and 0.91 for the sigmoid colectomy, showing high internal consistency between the experts. For the right hemicolectomy, 25 key steps were established; for the sigmoid colectomy, 24 key steps were established. Expert consensus on the key steps for laparoscopic right hemicolectomy and laparoscopic sigmoid colectomy was reached. These key steps will form the basis for a video-assisted teaching curriculum.
Wang, Sheng; Xing, Haiying; Hua, Chenlei; Guo, Hui-Shan; Zhang, Jie
2016-06-01
The soilborne fungal pathogen Verticillium dahliae infects a broad range of plant species to cause severe diseases. The availability of Verticillium genome sequences has provided opportunities for large-scale investigations of individual gene function in Verticillium strains using Agrobacterium tumefaciens-mediated transformation (ATMT)-based gene-disruption strategies. Traditional ATMT vectors require multiple cloning steps and elaborate characterization procedures to achieve successful gene replacement; thus, these vectors are not suitable for high-throughput ATMT-based gene deletion. Several advancements have been made that either involve simplification of the steps required for gene-deletion vector construction or increase the efficiency of the technique for rapid recombinant characterization. However, an ATMT binary vector that is both simple and efficient is still lacking. Here, we generated a USER-ATMT dual-selection (DS) binary vector, which combines both the advantages of the USER single-step cloning technique and the efficiency of the herpes simplex virus thymidine kinase negative-selection marker. Highly efficient deletion of three different genes in V. dahliae using the USER-ATMT-DS vector enabled verification that this newly-generated vector not only facilitates the cloning process but also simplifies the subsequent identification of fungal homologous recombinants. The results suggest that the USER-ATMT-DS vector is applicable for efficient gene deletion and suitable for large-scale gene deletion in V. dahliae.
Efficient synthesis of pure monotosylated beta-cyclodextrin and its dimers.
Tripodo, Giuseppe; Wischke, Christian; Neffe, Axel T; Lendlein, Andreas
2013-11-15
6-O-Monotosyl-β-cyclodextrin (mono-Ts-βCD) is one of the most important intermediates in the production of substituted βCD. So far, performing the monotosylation reaction and, in particular, the purification steps was challenging, relied on toxic solvents, and resulted in long and expensive procedures at, importantly, low yields. Here, the reaction of cyclodextrin with p-toluenesulfonyl chloride in aqueous environment is described to obtain a highly pure mono-Ts-βCD, for which a single-step purification with a cation exchange resin was applied. With this synthetic route and purification, yields could be increased from typically <10-15% to 35%, and organic solvents could be avoided. As characterized by FTIR, mass spectrometry, elemental analysis, and NMR, mono-Ts-βCD was obtained with a molar purity of >98mol%. From mono-Ts-βCD, β-cyclodextrin dimers linked by ethylenediamine (bis-Et-βCD) were successfully prepared (yield 93%, purity 96mol%) in a one-step approach using an anion exchange resin to trap leaving groups that typically interfere in the reaction. This synthesis procedure with a direct collection of side-products may be a general strategy applicable for nucleophilic substitution of tosylated cyclodextrins. Copyright © 2013 Elsevier Ltd. All rights reserved.
Kennedy, Zachary C.; Barrett, Christopher A.; Warner, Marvin G.
2017-03-01
Azides on the periphery of nanodiamond materials (ND) are of great utility because they have been shown to undergo Cu-catalyzed and Cu-free cycloaddition reactions with structurally diverse alkynes, affording particles tailored for applications in biology and materials science. However, current methods employed to access ND featuring azide groups typically require either harsh pretreatment procedures or multiple synthesis steps and use surface linking groups that may be susceptible to undesirable cleavage. Here in this paper we demonstrate an alternative single-step approach to producing linker-free, azide-functionalized ND. Our method was applied to low-cost, detonation-derived ND powders where surface carbonyl groups undergo silver-mediatedmore » decarboxylation and radical substitution with azide. ND with directly grafted azide groups were then treated with a variety of aliphatic, aromatic, and fluorescent alkynes to afford 1-(ND)-4-substituted-1,2,3-triazole materials under standard copper-catalyzed cycloaddition conditions. Surface modification steps were verified by characteristic infrared absorptions and elemental analyses. High loadings of triazole surface groups (up to 0.85 mmol g –1) were obtained as determined from thermogravimetric analysis. The azidation procedure disclosed is envisioned to become a valuable initial transformation in numerous future applications of ND.« less
Many-body strategies for multiqubit gates: Quantum control through Krawtchouk-chain dynamics
NASA Astrophysics Data System (ADS)
Groenland, Koen; Schoutens, Kareljan
2018-04-01
We propose a strategy for engineering multiqubit quantum gates. As a first step, it employs an eigengate to map states in the computational basis to eigenstates of a suitable many-body Hamiltonian. The second step employs resonant driving to enforce a transition between a single pair of eigenstates, leaving all others unchanged. The procedure is completed by mapping back to the computational basis. We demonstrate the strategy for the case of a linear array with an even number N of qubits, with specific X X +Y Y couplings between nearest neighbors. For this so-called Krawtchouk chain, a two-body driving term leads to the iSWAPN gate, which we numerically test for N =4 and 6.
HangOut: generating clean PSI-BLAST profiles for domains with long insertions.
Kim, Bong-Hyun; Cong, Qian; Grishin, Nick V
2010-06-15
Profile-based similarity search is an essential step in structure-function studies of proteins. However, inclusion of non-homologous sequence segments into a profile causes its corruption and results in false positives. Profile corruption is common in multidomain proteins, and single domains with long insertions are a significant source of errors. We developed a procedure (HangOut) that, for a single domain with specified insertion position, cleans erroneously extended PSI-BLAST alignments to generate better profiles. HangOut is implemented in Python 2.3 and runs on all Unix-compatible platforms. The source code is available under the GNU GPL license at http://prodata.swmed.edu/HangOut/. Supplementary data are available at Bioinformatics online.
NASA Technical Reports Server (NTRS)
Stetson, Howard K.; Haddock, Angie T.; Frank, Jeremy; Cornelius, Randy; Wang, Lui; Garner, Larry
2015-01-01
NASA is investigating a range of future human spaceflight missions, including both Mars-distance and Near Earth Object (NEO) targets. Of significant importance for these missions is the balance between crew autonomy and vehicle automation. As distance from Earth results in increasing communication delays, future crews need both the capability and authority to independently make decisions. However, small crews cannot take on all functions performed by ground today, and so vehicles must be more automated to reduce the crew workload for such missions. NASA's Advanced Exploration Systems Program funded Autonomous Mission Operations (AMO) project conducted an autonomous command and control experiment on-board the International Space Station that demonstrated single action intelligent procedures for crew command and control. The target problem was to enable crew initialization of a facility class rack with power and thermal interfaces, and involving core and payload command and telemetry processing, without support from ground controllers. This autonomous operations capability is enabling in scenarios such as initialization of a medical facility to respond to a crew medical emergency, and representative of other spacecraft autonomy challenges. The experiment was conducted using the Expedite the Processing of Experiments for Space Station (EXPRESS) rack 7, which was located in the Port 2 location within the U.S Laboratory onboard the International Space Station (ISS). Activation and deactivation of this facility is time consuming and operationally intensive, requiring coordination of three flight control positions, 47 nominal steps, 57 commands, 276 telemetry checks, and coordination of multiple ISS systems (both core and payload). Utilization of Draper Laboratory's Timeliner software, deployed on-board the ISS within the Command and Control (C&C) computers and the Payload computers, allowed development of the automated procedures specific to ISS without having to certify and employ novel software for procedure development and execution. The procedures contained the ground procedure logic and actions as possible to include fault detection and recovery capabilities. The autonomous operations concept includes a reduction of the amount of data a crew operator is required to verify during activation or de-activation, as well as integration of procedure execution status and relevant data in a single integrated display. During execution, the auto-procedures (via Timerliner) provide a step-by-step messaging paradigm and a high-level status upon termination. This messaging and high-level status is the only data generated for operator display. To enhance situational awareness of the operator, the Web-based Procedure Display (WebPD) provides a novel approach to the issues of procedure display and execution tracking. WebPD is a web based application that serves as the user interface for electronic procedure execution. It incorporates several aspects of the HTML5 standard. Procedures are written in a dialect of XML called Procedure Representation Language (PRL). WebPD tracks execution status in the procedure or procedures being displayed. WebPD aggregates and simplifies the auto-sequence execution status information, and formatted to be easily followed and understood by an operator who is not dedicated to actively monitoring the task. WebPD also provides an integrated data and control interface to pause or halt the execution in order to provide a check point of operation and to examine progress before starting the next sequence of activities. For this demonstration, the procedure was initiated and monitored from the ground. As the Timeliner sequences executed, their high-level execution status was written to PLMDM memory. This memory is read and downlinked via Ku-Band at a 1 Hz rate. The data containing the high-level execution status is de-commutated on the ground, and rebroadcast for WebPD consumption. A future demonstration will be performed onboard, with ISS astronauts initiating the operations instead of ground controllers. The AMO EXPRESS experiment demonstrated activation and de-activation of EXPRESS rack 7, providing the capability of future single button activations and deactivations of facility class racks. The experiment achieved numerous technical and operations 'firsts' for the ISS
Li, Yi-Jin; Li, Xue; Zhang, Shao-Xiao; Zhao, Yu-Long; Liu, Qun
2015-07-25
A novel copper-catalyzed [3+2] cycloaddition reaction of secondary amines with α-diazo compounds has been developed via a cross-dehydrogenative coupling process. The reaction involves a sequential aerobic oxidation/[3+2] cycloaddition/oxidative aromatization procedure and provides an efficient method for the construction of 1,2,3-triazoles in a single step in an atom-economic manner from readily available starting materials under very mild conditions.
Sanz, J M; Lopez, R; Garcia, J L
1988-05-23
Tertiary amines appear to be the minimal structure needed to convert in vitro the inactive form (E-form) of pneumococcal amidase to the catalytic active form (C-form). Diethylethanolamine was one of the compounds that converted the E-form, a finding that has been used successfully to develop an affinity chromatography system in DEAE-cellulose for the rapid and efficient purification of lytic enzymes of pneumococcus and its bacteriophages.
Toledo-Núñez, Citlali; Vera-Robles, L Iraís; Arroyo-Maya, Izlia J; Hernández-Arana, Andrés
2016-09-15
A frequent outcome in differential scanning calorimetry (DSC) experiments carried out with large proteins is the irreversibility of the observed endothermic effects. In these cases, DSC profiles are analyzed according to methods developed for temperature-induced denaturation transitions occurring under kinetic control. In the one-step irreversible model (native → denatured) the characteristics of the observed single-peaked endotherm depend on the denaturation enthalpy and the temperature dependence of the reaction rate constant, k. Several procedures have been devised to obtain the parameters that determine the variation of k with temperature. Here, we have elaborated on one of these procedures in order to analyze more complex DSC profiles. Synthetic data for a heat capacity curve were generated according to a model with two sequential reactions; the temperature dependence of each of the two rate constants involved was determined, according to the Eyring's equation, by two fixed parameters. It was then shown that our deconvolution procedure, by making use of heat capacity data alone, permits to extract the parameter values that were initially used. Finally, experimental DSC traces showing two and three maxima were analyzed and reproduced with relative success according to two- and four-step sequential models. Copyright © 2016 Elsevier Inc. All rights reserved.
Kaijser, Mirjam A; van Ramshorst, Gabrielle H; Emous, Marloes; Veeger, Nic J G M; van Wagensveld, Bart A; Pierie, Jean-Pierre E N
2018-04-09
Bariatric procedures are technically complex and skill demanding. In order to standardize the procedures for research and training, a Delphi analysis was performed to reach consensus on the practice of the laparoscopic gastric bypass and sleeve gastrectomy in the Netherlands. After a pre-round identifying all possible steps from literature and expert opinion within our study group, questionnaires were send to 68 registered Dutch bariatric surgeons, with 73 steps for bypass surgery and 51 steps for sleeve gastrectomy. Statistical analysis was performed to identify steps with and without consensus. This process was repeated to reach consensus of all necessary steps. Thirty-eight participants (56%) responded in the first round and 32 participants (47%) in the second round. After the first Delphi round, 19 steps for gastric bypass (26%) and 14 for sleeve gastrectomy (27%) gained full consensus. After the second round, an additional amount of 10 and 12 sub-steps was confirmed as key steps, respectively. Thirteen steps in the gastric bypass and seven in the gastric sleeve were deemed advisable. Our expert panel showed a high level of consensus expressed in a Cronbach's alpha of 0.82 for the gastric bypass and 0.87 for the sleeve gastrectomy. The Delphi consensus defined 29 steps for gastric bypass and 26 for sleeve gastrectomy as being crucial for correct performance of these procedures to the standards of our expert panel. These results offer a clear framework for the technical execution of these procedures.
Ruphuy, G; Souto-Lopes, M; Paiva, D; Costa, P; Rodrigues, A E; Monteiro, F J; Salgado, C L; Fernandes, M H; Lopes, J C; Dias, M M; Barreiro, M F
2018-04-01
Hybrid scaffolds composed of hydroxyapatite (HAp), in particular in its nanometric form (n-HAp), and chitosan (CS) are promising materials for non-load-bearing bone graft applications. The main constraints of their production concern the successful implementation of the final purification/neutralization and sterilization steps. Often, the used purification strategies can compromise scaffold structural features, and conventional sterilization techniques can result in material's thermal degradation and/or contamination with toxic residues. In this context, this work presents a process to produce n-HAp/CS scaffolds mimicking bone composition and structure, where an innovative single step based on supercritical CO 2 extraction was used for both purification and sterilization. A removal of 80% of the residual acetic acid was obtained (T = 75°C, p = 8.0 MPa, 2 extraction cycles of 2 h) giving rise to scaffolds exhibiting adequate interconnected porous structure, fast swelling and storage modulus compatible with non-load-bearing applications. Moreover, the obtained scaffolds showed cytocompatibility and osteoconductivity without further need of disinfection/sterilization procedures. Among the main advantages, the proposed process comprises only three steps (n-HAp/CS dispersion preparation; freeze-drying; and supercritical CO 2 extraction), and the supercritical CO 2 extraction show clear advantages over currently used procedures based on neutralization steps. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 965-975, 2018. © 2017 Wiley Periodicals, Inc.
Xu, Youming; Wu, Zhonghua; Yu, Jianhua; Wang, Shulong; Li, Fang; Chen, Jiushun; Liu, Jin; Chen, Kan
2012-06-01
To report our experience and assess the safety and efficacy of Doppler ultrasound-guided percutaneous nephrolithotomy (PCNL) with 2-step tract dilation for complex renal stones. From March 2009 to February 2011, 262 patients underwent PCNL. Eighty-three patients had a complete and 105 had partial staghorn calculus, and 74 had a renal pelvic stone of >2 cm in diameter. Thirty-five patients had renal surgical history. Doppler ultrasound-guided PCNL with 2-step tract dilation were performed. Stones were fragmented and cleared using a combination of ultrasonic and pneumatic lithotripters. All PCNL procedures were successful. Successful access to the collecting system was 100%. Although most of the cases (231/262) were managed satisfactorily by a single tract, a second tract was used in 31 cases. Mean operation time was 56 minutes (range 25-145). The primary stone-free rate of PCNL was 80.9%. There were 39 auxiliary procedures (13 second PCNL and 26 extracorporeal shock wave lithotripsy). One month after treatment, the overall stone-free rate was 92.7%. Five patients (1.9%) received blood transfusion. Eight patients (3.1%) with a postoperative fever of ≥38.5°C were cured by intravenous antibiotics. No other severe complications occurred. The mean postoperative stay was 3.8 days (range 2-12). Doppler ultrasound-guided PCNL with 2-step tract dilation for complex renal stones is safe, effective, and worthy of wider use in clinical practice. Copyright © 2012 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Bergese, P.; Bontempi, E.; Depero, L. E.
2006-10-01
X-ray reflectivity (XRR) is a non-destructive, accurate and fast technique for evaluating film density. Indeed, sample-goniometer alignment is a critical experimental factor and the overriding error source in XRR density determination. With commercial single-wavelength X-ray reflectometers, alignment is difficult to control and strongly depends on the operator. In the present work, the contribution of misalignment on density evaluation error is discussed, and a novel procedure (named XRR-density evaluation or XRR-DE method) to minimize the problem will be presented. The method allows to overcome the alignment step through the extrapolation of the correct density value from appropriate non-specular XRR data sets. This procedure is operator independent and suitable for commercial single-wavelength X-ray reflectometers. To test the XRR-DE method, single crystals of TiO 2 and SrTiO 3 were used. In both cases the determined densities differed from the nominal ones less than 5.5%. Thus, the XRR-DE method can be successfully applied to evaluate the density of thin films for which only optical reflectivity is today used. The advantage is that this method can be considered thickness independent.
Aissaoui, Neyssene; Chobert, Jean-Marc; Haertlé, Thomas; Marzouki, M Nejib; Abidi, Ferid
2017-06-01
This study reports the purification and biochemical characterization of an extracellular neutral protease from the fungus Trichoderma harzianum. The protease (Th-Protease) was purified from the culture supernatant to homogeneity by a three-step procedure with 14.2% recovery and 9.06-fold increase in specific activity. The purified enzyme appeared as a single protein band after sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) with a molecular mass of about 20 kDa. The optimum pH and temperature for the proteolytic activity were pH 7.0 and 40 °C, respectively. The enzyme was then investigated for its potential application in the production of antibacterial peptides. Interestingly, Scorpaena notata viscera protein hydrolysate prepared using the purified serine protease (Th-Protease) showed remarkable in vitro antibacterial activities. A peptide with a high antibacterial activity was further purified by a three-step procedure, and its sequence was identified as FPIGMGHGSRPA. The result of this study offers a promising alternative to produce natural antibacterial peptides from fish protein hydrolysate.
Blumrich, Matthias A.; Salapura, Valentina
2010-11-02
An apparatus and method are disclosed for single-stepping coherence events in a multiprocessor system under software control in order to monitor the behavior of a memory coherence mechanism. Single-stepping coherence events in a multiprocessor system is made possible by adding one or more step registers. By accessing these step registers, one or more coherence requests are processed by the multiprocessor system. The step registers determine if the snoop unit will operate by proceeding in a normal execution mode, or operate in a single-step mode.
Solution of elliptic PDEs by fast Poisson solvers using a local relaxation factor
NASA Technical Reports Server (NTRS)
Chang, Sin-Chung
1986-01-01
A large class of two- and three-dimensional, nonseparable elliptic partial differential equations (PDEs) is presently solved by means of novel one-step (D'Yakanov-Gunn) and two-step (accelerated one-step) iterative procedures, using a local, discrete Fourier analysis. In addition to being easily implemented and applicable to a variety of boundary conditions, these procedures are found to be computationally efficient on the basis of the results of numerical comparison with other established methods, which lack the present one's: (1) insensitivity to grid cell size and aspect ratio, and (2) ease of convergence rate estimation by means of the coefficient of the PDE being solved. The two-step procedure is numerically demonstrated to outperform the one-step procedure in the case of PDEs with variable coefficients.
AMO EXPRESS: A Command and Control Experiment for Crew Autonomy
NASA Technical Reports Server (NTRS)
Stetson, Howard K.; Frank, Jeremy; Cornelius, Randy; Haddock, Angie; Wang, Lui; Garner, Larry
2015-01-01
NASA is investigating a range of future human spaceflight missions, including both Mars-distance and Near Earth Object (NEO) targets. Of significant importance for these missions is the balance between crew autonomy and vehicle automation. As distance from Earth results in increasing communication delays, future crews need both the capability and authority to independently make decisions. However, small crews cannot take on all functions performed by ground today, and so vehicles must be more automated to reduce the crew workload for such missions. NASA's Advanced Exploration Systems Program funded Autonomous Mission Operations (AMO) project conducted an autonomous command and control demonstration of intelligent procedures to automatically initialize a rack onboard the International Space Station (ISS) with power and thermal interfaces, and involving core and payload command and telemetry processing, without support from ground controllers. This autonomous operations capability is enabling in scenarios such as a crew medical emergency, and representative of other spacecraft autonomy challenges. The experiment was conducted using the Expedite the Processing of Experiments for Space Station (EXPRESS) rack 7, which was located in the Port 2 location within the U.S Laboratory onboard the International Space Station (ISS). Activation and deactivation of this facility is time consuming and operationally intensive, requiring coordination of three flight control positions, 47 nominal steps, 57 commands, 276 telemetry checks, and coordination of multiple ISS systems (both core and payload). The autonomous operations concept includes a reduction of the amount of data a crew operator is required to verify during activation or de-activation, as well as integration of procedure execution status and relevant data in a single integrated display. During execution, the auto-procedures provide a step-by-step messaging paradigm and a high level status upon termination. This messaging and high level status is the only data generated for operator display. To enhance situational awareness of the operator, the Web-based Procedure Display (WebPD) provides a novel approach to the issues of procedure display and execution tracking. For this demonstration, the procedure was initiated and monitored from the ground. As the Timeliner sequences executed, their high level execution status was transmitted to ground, for WebPD consumption.
Comparison study on mechanical properties single step and three step artificial aging on duralium
NASA Astrophysics Data System (ADS)
Tsamroh, Dewi Izzatus; Puspitasari, Poppy; Andoko, Sasongko, M. Ilman N.; Yazirin, Cepi
2017-09-01
Duralium is kind of non-ferro alloy that used widely in industrial. That caused its properties such as mild, high ductility, and resistance from corrosion. This study aimed to know mechanical properties of duralium on single step and three step articial aging process. Mechanical properties that discussed in this study focused on toughness value, tensile strength, and microstructure of duralium. Toughness value of single step artificial aging was 0.082 joule/mm2, and toughness value of three step artificial aging was 0,0721 joule/mm2. Duralium tensile strength of single step artificial aging was 32.36 kgf/mm^2, and duralium tensile strength of three step artificial aging was 32,70 kgf/mm^2. Based on microstructure photo of duralium of single step artificial aging showed that precipitate (θ) was not spreading evenly indicated by black spot which increasing the toughness of material. While microstructure photo of duralium that treated by three step artificial aging showed that it had more precipitate (θ) spread evenly compared with duralium that treated by single step artificial aging.
Short bowel mucosal morphology, proliferation and inflammation at first and repeat STEP procedures.
Mutanen, Annika; Barrett, Meredith; Feng, Yongjia; Lohi, Jouko; Rabah, Raja; Teitelbaum, Daniel H; Pakarinen, Mikko P
2018-04-17
Although serial transverse enteroplasty (STEP) improves function of dilated short bowel, a significant proportion of patients require repeat surgery. To address underlying reasons for unsuccessful STEP, we compared small intestinal mucosal characteristics between initial and repeat STEP procedures in children with short bowel syndrome (SBS). Fifteen SBS children, who underwent 13 first and 7 repeat STEP procedures with full thickness small bowel samples at median age 1.5 years (IQR 0.7-3.7) were included. The specimens were analyzed histologically for mucosal morphology, inflammation and muscular thickness. Mucosal proliferation and apoptosis was analyzed with MIB1 and Tunel immunohistochemistry. Median small bowel length increased 42% by initial STEP and 13% by repeat STEP (p=0.05), while enteral caloric intake increased from 6% to 36% (p=0.07) during 14 (12-42) months between the procedures. Abnormal mucosal inflammation was frequently observed both at initial (69%) and additional STEP (86%, p=0.52) surgery. Villus height, crypt depth, enterocyte proliferation and apoptosis as well as muscular thickness were comparable at first and repeat STEP (p>0.05 for all). Patients, who required repeat STEP tended to be younger (p=0.057) with less apoptotic crypt cells (p=0.031) at first STEP. Absence of ileocecal valve associated with increased intraepithelial leukocyte count and reduced crypt cell proliferation index (p<0.05 for both). No adaptive mucosal hyperplasia or muscular alterations occurred between first and repeat STEP. Persistent inflammation and lacking mucosal growth may contribute to continuing bowel dysfunction in SBS children, who require repeat STEP procedure, especially after removal of the ileocecal valve. Level IV, retrospective study. Copyright © 2018 Elsevier Inc. All rights reserved.
Elastic-net regularization approaches for genome-wide association studies of rheumatoid arthritis.
Cho, Seoae; Kim, Haseong; Oh, Sohee; Kim, Kyunga; Park, Taesung
2009-12-15
The current trend in genome-wide association studies is to identify regions where the true disease-causing genes may lie by evaluating thousands of single-nucleotide polymorphisms (SNPs) across the whole genome. However, many challenges exist in detecting disease-causing genes among the thousands of SNPs. Examples include multicollinearity and multiple testing issues, especially when a large number of correlated SNPs are simultaneously tested. Multicollinearity can often occur when predictor variables in a multiple regression model are highly correlated, and can cause imprecise estimation of association. In this study, we propose a simple stepwise procedure that identifies disease-causing SNPs simultaneously by employing elastic-net regularization, a variable selection method that allows one to address multicollinearity. At Step 1, the single-marker association analysis was conducted to screen SNPs. At Step 2, the multiple-marker association was scanned based on the elastic-net regularization. The proposed approach was applied to the rheumatoid arthritis (RA) case-control data set of Genetic Analysis Workshop 16. While the selected SNPs at the screening step are located mostly on chromosome 6, the elastic-net approach identified putative RA-related SNPs on other chromosomes in an increased proportion. For some of those putative RA-related SNPs, we identified the interactions with sex, a well known factor affecting RA susceptibility.
Dynamic Non-Rigid Objects Reconstruction with a Single RGB-D Sensor
Zuo, Xinxin; Du, Chao; Wang, Runxiao; Zheng, Jiangbin; Yang, Ruigang
2018-01-01
This paper deals with the 3D reconstruction problem for dynamic non-rigid objects with a single RGB-D sensor. It is a challenging task as we consider the almost inevitable accumulation error issue in some previous sequential fusion methods and also the possible failure of surface tracking in a long sequence. Therefore, we propose a global non-rigid registration framework and tackle the drifting problem via an explicit loop closure. Our novel scheme starts with a fusion step to get multiple partial scans from the input sequence, followed by a pairwise non-rigid registration and loop detection step to obtain correspondences between neighboring partial pieces and those pieces that form a loop. Then, we perform a global registration procedure to align all those pieces together into a consistent canonical space as guided by those matches that we have established. Finally, our proposed model-update step helps fixing potential misalignments that still exist after the global registration. Both geometric and appearance constraints are enforced during our alignment; therefore, we are able to get the recovered model with accurate geometry as well as high fidelity color maps for the mesh. Experiments on both synthetic and various real datasets have demonstrated the capability of our approach to reconstruct complete and watertight deformable objects. PMID:29547562
Baran, Richard; Northen, Trent R
2013-10-15
Untargeted metabolite profiling using liquid chromatography and mass spectrometry coupled via electrospray ionization is a powerful tool for the discovery of novel natural products, metabolic capabilities, and biomarkers. However, the elucidation of the identities of uncharacterized metabolites from spectral features remains challenging. A critical step in the metabolite identification workflow is the assignment of redundant spectral features (adducts, fragments, multimers) and calculation of the underlying chemical formula. Inspection of the data by experts using computational tools solving partial problems (e.g., chemical formula calculation for individual ions) can be performed to disambiguate alternative solutions and provide reliable results. However, manual curation is tedious and not readily scalable or standardized. Here we describe an automated procedure for the robust automated mass spectra interpretation and chemical formula calculation using mixed integer linear programming optimization (RAMSI). Chemical rules among related ions are expressed as linear constraints and both the spectra interpretation and chemical formula calculation are performed in a single optimization step. This approach is unbiased in that it does not require predefined sets of neutral losses and positive and negative polarity spectra can be combined in a single optimization. The procedure was evaluated with 30 experimental mass spectra and was found to effectively identify the protonated or deprotonated molecule ([M + H](+) or [M - H](-)) while being robust to the presence of background ions. RAMSI provides a much-needed standardized tool for interpreting ions for subsequent identification in untargeted metabolomics workflows.
A five-step procedure for the clinical use of the MPD in neuropsychological assessment of children.
Wallbrown, F H; Fuller, G B
1984-01-01
Described a five-step procedure that can be used to detect organicity on the basis of children's performance on the Minnesota Percepto Diagnostic Test (MPD). The first step consists of examining the T score for rotations to determine whether it is below the cut-off score, which has been established empirically as an indicator of organicity. The second step consists of matching the examinee's configuration of error scores, separation of circle-diamond (SpCD), distortion of circle-diamond (DCD), and distortion of dots (DD), with empirically derived tables. The third step consists of considering the T score for rotations and error configuration jointly. The fourth step consists of using empirically established discriminant equations, and the fifth step involves using data from limits testing and other data sources. The clinical and empirical bases for the five-step procedure also are discussed.
Technology of welding aluminum alloys-II
NASA Technical Reports Server (NTRS)
1978-01-01
Step-by-step procedures were developed for high integrity manual and machine welding of aluminum alloys. Detailed instructions are given for each step with tables and graphs to specify materials and dimensions. Throughout work sequence, processing procedure designates manufacturing verification points and inspection points.
ERIC Educational Resources Information Center
Perley, Gordon F.
This is a guide for standard operating job procedures for the pump station process of wastewater treatment plants. Step-by-step instructions are given for pre-start up inspection, start-up procedures, continuous routine operation procedures, and shut-down procedures. A general description of the equipment used in the process is given. Two…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bly, Aaron; Oxstrand, Johanna; Le Blanc, Katya L
2015-02-01
Most activities that involve human interaction with systems in a nuclear power plant are guided by procedures. Traditionally, the use of procedures has been a paper-based process that supports safe operation of the nuclear power industry. However, the nuclear industry is constantly trying to find ways to decrease the human error rate, especially the human errors associated with procedure use. Advances in digital technology make computer-based procedures (CBPs) a valid option that provides further enhancement of safety by improving human performance related to procedure use. The transition from paper-based procedures (PBPs) to CBPs creates a need for a computer-based proceduremore » system (CBPS). A CBPS needs to have the ability to perform logical operations in order to adjust to the inputs received from either users or real time data from plant status databases. Without the ability for logical operations the procedure is just an electronic copy of the paper-based procedure. In order to provide the CBPS with the information it needs to display the procedure steps to the user, special care is needed in the format used to deliver all data and instructions to create the steps. The procedure should be broken down into basic elements and formatted in a standard method for the CBPS. One way to build the underlying data architecture is to use an Extensible Markup Language (XML) schema, which utilizes basic elements to build each step in the smart procedure. The attributes of each step will determine the type of functionality that the system will generate for that step. The CBPS will provide the context for the step to deliver referential information, request a decision, or accept input from the user. The XML schema needs to provide all data necessary for the system to accurately perform each step without the need for the procedure writer to reprogram the CBPS. The research team at the Idaho National Laboratory has developed a prototype CBPS for field workers as well as the underlying data structure for such CBPS. The objective of the research effort is to develop guidance on how to design both the user interface and the underlying schema. This paper will describe the result and insights gained from the research activities conducted to date.« less
Sánchez-Martín, J; Ghebremichael, K; Beltrán-Heredia, J
2010-08-01
The coagulant proteins from Moringa oleifera purified with single-step and two-step ion-exchange processes were used for the coagulation of surface water from Meuse river in The Netherlands. The performances of the two purified coagulants and the crude extract were assessed in terms of turbidity and DOC removal. The results indicated that the optimum dosage of the single-step purified coagulant was more than two times higher compared to the two-step purified coagulant in terms of turbidity removal. And the residual DOC in the two-step purified coagulant was lower than in single-step purified coagulant or crude extract. (c) 2010 Elsevier Ltd. All rights reserved.
Balling, Horst
2018-05-01
Prospective single-center cohort study to record additional time requirements and radiation dose in navigation-assisted O-arm-controlled pedicle screw (PS) instrumentations. The aim of this study was to evaluate amount of extra-time and radiation dose for navigation-assisted PS instrumentations of the thoracolumbosacral spine using O-arm 3D-real-time-navigation (O3DN) compared to non-navigated spinal procedures (NNSPs) with a single C-arm and postoperative computed tomography (CT) scan for controlling PS positions. 3D-navigation is reported to enhance PS insertion accuracy. But time-consuming navigational steps and considerable additional radiation doses seem to limit this modern technique's attraction. A detailed analysis of additional time demand and extra-radiation dose in 3D-navigated spine surgery is not provided in literature, yet. From February 2011 through July 2015, 306 consecutive posterior instrumentations were performed in vertebral levels T10-S1 using O3DN for PS insertion. The duration of procedure-specific navigational steps of the overall collective (I) and the last cohort of 50 consecutive O3DN-surgeries (II) was compared to the average duration of analogous surgical steps in 100 consecutive NNSP using a single C-arm. 3D-radiation dose (dose-length-product, DLP) of navigational and postinstrumentation O-arm scans in group I and II was compared to the average DLP of 100 diagnostic lumbar CT scans. The average presurgical time from patient positioning on the operating table to skin incision was 46.2 ± 10.1 minutes (O3DN, I) and 40.6 ± 9.8 minutes (O3DN, II) versus 30.6 ± 8.3 minutes (NNSP) (P < 0.001, each). Intraoperative interruptions for scanning and data processing took 3.0 ± 0.6 minutes. DLPs averaged 865.1 ± 360.8 mGycm (O3DN, I) and 562.1 ± 352.6 mGycm (O3DN, II) compared to 575.5 ± 316.5 mGycm in diagnostic lumbar CT scans (P < 0.001 (I), P ≈ 0.81 [II]). After procedural experience, navigated surgeries can be performed with an additional time demand of 13.0 minutes compared to NNSP, and with a total DLP below that of a diagnostic lumbar CT scan (P ≈ 0.81). 4.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hanc, Emil; Zając, Wojciech, E-mail: wojciech.zajac@agh.edu.pl; Lu, Li
Ceramic oxides exhibiting high lithium-ion mobility at room temperature receive broad attention as candidate electrolytes for lithium batteries. Lithium-stuffed garnets from the Li{sub 7}La{sub 3}Zr{sub 2}O{sub 12} group seem to be especially promising because of their high ionic conductivity at room temperature and their electrochemical stability. In this work, we discuss factors that affect formation of the garnet in its bulk form or in the form of thick and thin films. We demonstrate that zinc oxide can be applied as a sintering aid that facilitate the formation of the highly conducting cubic Li{sub 7}La{sub 3}Zr{sub 2}O{sub 12} garnet phase inmore » a single-step sintering procedure. Based on our experience with the single-step sintering experiments, we successfully fabricated a thick-film membrane consisting of a garnet solid electrolyte using the tape casting technique. In order to reduce the thickness of the electrolyte even further we investigated the fabrication of a thin-film Li{sub 7}La{sub 3}Zr{sub 2}O{sub 12} electrolyte by means of the pulsed laser deposition technique.« less
Terenteva, E A; Apyari, V V; Dmitrienko, S G; Garshev, A V; Volkov, P A; Zolotov, Yu A
2018-04-01
Positively charged polyhexamethylene guanidine hydrochloride-stabilized silver nanoparticles (PHMG-AgNPs) were prepared and applied as a colorimetric probe for single-step determination of pyrophosphate and sulfate. The approach is based on the nanoparticles aggregation leading to change in their absorption spectra and color of the solution. Due to both electrostatic and steric stabilization these nanoparticles show decreased sensitivity relatively to many common anions, which allows for simple and rapid direct single-step determination of pyrophosphate and sulfate. Effects of different factors (time of interaction, pH, concentrations of anions and the nanoparticles) on aggregation of PHMG-AgNPs and analytical performance of the procedure were investigated. The method allows for the determination of pyrophosphate and sulfate in the range of 0.16-2μgmL -1 and 20-80μgmL -1 with RSD of 2-5%, respectively. The analysis can be performed using either spectrophotometry or naked-eye detection. Practical application of the method was shown by the example of pyrophosphate determination in baking powder sample. Copyright © 2017 Elsevier B.V. All rights reserved.
[Adaptation of humans to walking in semi-hard and flexible space suits under terrestrial gravity].
Panfilov, V E
2011-01-01
The spacesuit donning-on procedure can be viewed as the combining of two kinematic circuits into a single human-spacesuit functional system (HSS) for implementation of extravehicular operations. Optimal human-spacesuit interaction hinges on controllability and coordination of HSS mobile components, and also spacesuit slaving to the central nervous system (CNS) mediated through the human locomotion apparatus. Analysis of walking patterns in semi-hard and flexible spacesuits elucidated the direct and feedback relations between the external (spacesuit) and external (locomotion apparatus and CNS) circuits Lack of regularity in the style of spacesuit design creates difficulties for the direct CNS control of locomotion. Consequently, it is necessary to modify the locomotion command program in order to resolve these difficulties and to add flexibility to CNS control The analysis also helped trace algorithm of program modifications with the ultimate result of induced (forced) walk optimization. Learning how to walk in spacesuit Berkut requires no more than 2500 single steps, whereas about 300 steps must be made to master walk skills in spacesuit SKV.
Factors affecting GEBV accuracy with single-step Bayesian models.
Zhou, Lei; Mrode, Raphael; Zhang, Shengli; Zhang, Qin; Li, Bugao; Liu, Jian-Feng
2018-01-01
A single-step approach to obtain genomic prediction was first proposed in 2009. Many studies have investigated the components of GEBV accuracy in genomic selection. However, it is still unclear how the population structure and the relationships between training and validation populations influence GEBV accuracy in terms of single-step analysis. Here, we explored the components of GEBV accuracy in single-step Bayesian analysis with a simulation study. Three scenarios with various numbers of QTL (5, 50, and 500) were simulated. Three models were implemented to analyze the simulated data: single-step genomic best linear unbiased prediction (GBLUP; SSGBLUP), single-step BayesA (SS-BayesA), and single-step BayesB (SS-BayesB). According to our results, GEBV accuracy was influenced by the relationships between the training and validation populations more significantly for ungenotyped animals than for genotyped animals. SS-BayesA/BayesB showed an obvious advantage over SSGBLUP with the scenarios of 5 and 50 QTL. SS-BayesB model obtained the lowest accuracy with the 500 QTL in the simulation. SS-BayesA model was the most efficient and robust considering all QTL scenarios. Generally, both the relationships between training and validation populations and LD between markers and QTL contributed to GEBV accuracy in the single-step analysis, and the advantages of single-step Bayesian models were more apparent when the trait is controlled by fewer QTL.
Marckmann, G; In der Schmitten, J
2014-05-01
Under the current conditions in the health care system, physicians inevitably have to take responsibility for the cost dimension of their decisions on the level of single cases. This article, therefore, discusses the question how physicians can integrate cost considerations into their clinical decisions at the microlevel in a medically rational and ethically justified way. We propose a four-step model for "ethical cost-consciousness": (1) forego ineffective interventions as required by good evidence-based medicine, (2) respect individual patient preferences, (3) minimize the diagnostic and therapeutic effort to achieve a certain treatment goal, and (4) forego expensive interventions that have only a small or unlikely (net) benefit for the patient. Steps 1-3 are ethically justified by the principles of beneficence, nonmaleficence, and respect for autonomy, step 4 by the principles of justice. For decisions on step 4, explicit cost-conscious guidelines should be developed locally or regionally. Following the four-step model can contribute to ethically defensible, cost-conscious decision-making at the microlevel. In addition, physicians' rationing decisions should meet basic standards of procedural fairness. Regular cost-case discussions and clinical ethics consultation should be available as decision support. Implementing step 4, however, requires first of all a clear political legitimation with the corresponding legal framework.
Patient and tissue identification in the assisted reproductive technology laboratory.
Pomeroy, Kimball O; Racowsky, Catherine
2012-06-01
Several high-profile cases involving in vitro fertilization have recently received considerable media attention and highlight the importance of assuring patient and tissue identification. Within the assisted reproductive technology (ART) laboratory, there are many steps where wrong patient or tissue identity could have drastic results. Erroneous identity can result in tragic consequences for the patient, the laboratory, and for those working in the program as a whole. Such errors can result in enormous psychological and financial costs, as well as a loss in confidence. There are several critical steps that should be taken every single time and for each specific procedure performed in the ART laboratory to ensure the correct identification of patients and their tissue. These steps should be detailed in protocols that include the method of identification, the two unique identifiers that will be used, the sources of these identifiers, and often a system in which more than one person is involved in the identification. Each protocol should ideally include a checklist that is actively used for the implementation of each procedure. The protocol should also indicate what to do if the identification does not match up, including rapid handling and notification of the patient involved in the error. All ART laboratories should instill in their employees an atmosphere of full and open disclosure for cases where mistakes are made. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Canopy, Erin; Evans, Matt; Boehler, Margaret; Roberts, Nicole; Sanfey, Hilary; Mellinger, John
2015-10-01
Endoscopic retrograde cholangiopancreatography is a challenging procedure performed by surgeons and gastroenterologists. We employed cognitive task analysis to identify steps and decision points for this procedure. Standardized interviews were conducted with expert gastroenterologists (7) and surgeons (4) from 4 institutions. A procedural step and cognitive decision point protocol was created from audio-taped transcriptions and was refined by 5 additional surgeons. Conceptual elements, sequential actions, and decision points were iterated for 5 tasks: patient preparation, duodenal intubation, selective cannulation, imaging interpretation with related therapeutic intervention, and complication management. A total of 180 steps were identified. Gastroenterologists identified 34 steps not identified by surgeons, and surgeons identified 20 steps not identified by gastroenterologists. The findings suggest that for complex procedures performed by diverse practitioners, more experts may help delineate distinctive emphases differentiated by training background and type of practice. Copyright © 2015 Elsevier Inc. All rights reserved.
Siboni, Renaud; Joseph, Etienne; Blasco, Laurent; Barbe, Coralie; Bajolet, Odile; Diallo, Saïdou; Ohl, Xavier
2018-06-07
Management of septic non-union of the tibia requires debridement and excision of all infected bone and soft tissues. Various surgical techniques have been described to fill the bone defect. The "Induced Membrane" technique, described by A. C. Masquelet in 1986, is a two-step procedure using a PMMA cement spacer around which an induced membrane develops, to be used in the second step as a bone graft holder for the bone graft. The purpose of this study was to assess our clinical and radiological results with this technique in a series managed in our department. Nineteen traumatic septic non-unions of the tibia were included in a retrospective single-center study between November 2007 and November 2014. All patients were followed up clinically and radiologically to assess bone union time. Multivariate analysis was used to identify factors influencing union. The series comprised 4 women and 14 men (19 legs); mean age was 53.9 years. Vascularized flap transfer was required in 26% of cases before the first stage of treatment. All patients underwent a two-step procedure, with a mean interval of 7.9 weeks. Mean bone defect after the first step was 52.4mm. The bone graft was harvested from the iliac crest in the majority of cases (18/19). The bone was stabilized with an external fixator, locking plate or plaster cast after the second step. Mean follow-up was 34 months. Bony union rate was 89% (17/19), at a mean 16 months after step 2. Eleven patients underwent one or more (mean 2.1) complementary procedures. Severity of index fracture skin opening was significantly correlated with union time (Gustilo III vs. Gustilo I or II, p=0.028). A trend was found for negative impact of smoking on union (p=0.06). Bone defect size did not correlate with union rate or time. The union rate was acceptable, at 89%, but with longer union time than reported in the literature. Many factors could explain this: lack of rigid fixation after step 2 (in case of plaster cast or external fixator), or failure to cease smoking. The results showed that the induced membrane technique is effective in treating tibial septic non-union, but could be improved by stable fixation after the second step and by cessation of smoking. IV, Retrospective study. Copyright © 2018 Elsevier Masson SAS. All rights reserved.
Learning target masks in infrared linescan imagery
NASA Astrophysics Data System (ADS)
Fechner, Thomas; Rockinger, Oliver; Vogler, Axel; Knappe, Peter
1997-04-01
In this paper we propose a neural network based method for the automatic detection of ground targets in airborne infrared linescan imagery. Instead of using a dedicated feature extraction stage followed by a classification procedure, we propose the following three step scheme: In the first step of the recognition process, the input image is decomposed into its pyramid representation, thus obtaining a multiresolution signal representation. At the lowest three levels of the Laplacian pyramid a neural network filter of moderate size is trained to indicate the target location. The last step consists of a fusion process of the several neural network filters to obtain the final result. To perform this fusion we use a belief network to combine the various filter outputs in a statistical meaningful way. In addition, the belief network allows the integration of further knowledge about the image domain. By applying this multiresolution recognition scheme, we obtain a nearly scale- and rotational invariant target recognition with a significantly decreased false alarm rate compared with a single resolution target recognition scheme.
Deng, Xi; Schröder, Simone; Redweik, Sabine; Wätzig, Hermann
2011-06-01
Gel electrophoresis (GE) is a very common analytical technique for proteome research and protein analysis. Despite being developed decades ago, there is still a considerable need to improve its precision. Using the fluorescence of Colloidal Coomassie Blue -stained proteins in near-infrared (NIR), the major error source caused by the unpredictable background staining is strongly reduced. This result was generalized for various types of detectors. Since GE is a multi-step procedure, standardization of every single step is required. After detailed analysis of all steps, the staining and destaining were identified as the major source of the remaining variation. By employing standardized protocols, pooled percent relative standard deviations of 1.2-3.1% for band intensities were achieved for one-dimensional separations in repetitive experiments. The analysis of variance suggests that the same batch of staining solution should be used for gels of one experimental series to minimize day-to-day variation and to obtain high precision. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Putzer, David; Moctezuma, Jose Luis; Nogler, Michael
2017-11-01
An increasing number of orthopaedic surgeons are using computer aided planning tools for bone removal applications. The aim of the study was to consolidate a set of generic functions to be used for a 3D computer assisted planning or simulation. A limited subset of 30 surgical procedures was analyzed and verified in 243 surgical procedures of a surgical atlas. Fourteen generic functions to be used in 3D computer assisted planning and simulations were extracted. Our results showed that the average procedure comprises 14 ± 10 (SD) steps with ten different generic planning steps and four generic bone removal steps. In conclusion, the study shows that with a limited number of 14 planning functions it is possible to perform 243 surgical procedures out of Campbell's Operative Orthopedics atlas. The results may be used as a basis for versatile generic intraoperative planning software.
Hufnagel, Hansjörg; Huebner, Ansgar; Gülch, Carina; Güse, Katharina; Abell, Chris; Hollfelder, Florian
2009-06-07
We present a modular system of microfluidic PDMS devices designed to incorporate the steps necessary for cell biological assays based on mammalian tissue culture 'on-chip'. The methods described herein include the on-chip immobilization and culturing of cells as well as their manipulation by transfection. Assessment of cell viability by flow cytrometry suggests low attrition rates (<3%) and excellent growth properties in the device for up to 7 days for CHO-K1 cells. To demonstrate that key procedures from the repertoire of cell biology are possible in this format, transfection of a reporter gene (encoding green fluorescent protein) was carried out. The modular design enables efficient detachment and recollection of cells and allows assessment of the success of transfection achieved on-chip. The transfection levels (20%) are comparable to standard large scale procedures and more than 500 cells could be transfected. Finally, cells are transferred into microfluidic microdoplets, where in principle a wide range of subsequent assays can be carried out at the single cell level in droplet compartments. The procedures developed for this modular device layout further demonstrate that commonly used methods in cell biology involving mammalian cells can be reliably scaled down to allow single cell investigations in picolitre volumes.
Ulrich, G.A.; Krumholz, L.R.; Suflita, J.M.
1997-01-01
A simplified passive extraction procedure for quantifying reduced inorganic sulfur compounds from sediments and water is presented. This method may also be used for the estimation of sulfate reduction rates. Efficient extraction of FeS, FeS(inf2), and S(sup2-) was obtained with this procedure; however, the efficiency for S(sup0) depended on the form that was tested. Passive extraction can be used with samples containing up to 20 mg of reduced sulfur. We demonstrated the utility of this technique in a determination of both sulfate reduction rates and reduced inorganic sulfur pools in marine and freshwater sediments. A side-by-side comparison of the passive extraction method with the established single-step distillation technique yielded comparable results with a fraction of the effort.
Endoscopic ultrasound-guided biliary drainage
Chavalitdhamrong, Disaya; Draganov, Peter V
2012-01-01
Endoscopic ultrasound (EUS)-guided biliary drainage has emerged as a minimally invasive alternative to percutaneous and surgical interventions for patients with biliary obstruction who had failed endoscopic retrograde cholangiopancreatography (ERCP). EUS-guided biliary drainage has become feasible due to the development of large channel curvilinear therapeutic echo-endoscopes and the use of real-time ultrasound and fluoroscopy imaging in addition to standard ERCP devices and techniques. EUS-guided biliary drainage is an attractive option because of its minimally invasive, single step procedure which provides internal biliary decompression. Multiple investigators have reported high success and low complication rates. Unfortunately, high quality prospective data are still lacking. We provide detailed review of the use of EUS for biliary drainage from the perspective of practicing endoscopists with specific focus on the technical aspects of the procedure. PMID:22363114
Analysis of D-penicillamine by gas chromatography utilizing nitrogen--phosphorus detection.
Rushing, L G; Hansen, E B; Thompson, H C
1985-01-11
A method is presented for the analysis of the "orphan" drug D-penicillamine (D-Pa), which is used for the treatment of the inherited rare copper metabolism dysfunction known as Wilson's disease, by assaying a derivative of the compound by gas chromatography employing a rubidium sensitized nitrogen--phosphorus detector. Analytical procedures are described for the analyses of residues of D-Pa X HCl salt in animal feed and for the analyses of the salt or free base from aqueous solutions by utilizing a single-step double derivatization with diazomethane--acetone. Stability data for D-Pa X HCl in animal feed and for the free base in water are presented. An ancillary fluorescence derivatization procedure for the analysis of D-Pa in water is also reported.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xie, Xu; Islam, Ahmad E.; Seabron, Eric
2015-04-07
Aligned arrays of semiconducting single-walled carbon nanotubes (s-SWNTs) represent ideal configurations for use of this class of material in high performance electronics. Development of means for removing the metallic SWNTs (m-SWNTs) in as-grown arrays represents an essential challenge. Here, we introduce a simple scheme that achieves this type of purification using direct, selective current injection through interdigitated electrodes into the m-SWNTs, to allow their complete removal using processes of thermocapillarity and dry etching. Experiments and numerical simulations establish the fundamental aspects that lead to selectivity in this process, thereby setting design rules for optimization. Single-step purification of arrays that includemore » thousands of SWNTs demonstrates the effectiveness and simplicity of the procedures. The result is a practical route to large-area aligned arrays of purely s-SWNTs with low-cost experimental setups.« less
Fabrication of p(+)-n junction GaAs solar cells by a novel method
NASA Technical Reports Server (NTRS)
Ghandhi, S. K.; Mathur, G.; Rode, H.; Borrego, J. M.
1984-01-01
A novel method for making p(+)-n diffused junction GaAs solar cells, with the formation of a diffusion source, an anti-reflective coating, and a protective cover glass in a single chemical-vapor deposition operation is discussed. Consideration is given to device fabrication and to solar-cell characteristics. The advantages of the technique are that the number of process steps is kept to an absolute minimum, the fabrication procedure is low-cost, and the GaAs surface is protected during the entire operation.
"Ring pledget": a new concept for secure apex closure during transapical aortic valve implantation.
Astarci, Parla; Glineur, David; Kefer, Joelle; Renkin, Jean; Vanoverschelde, Jean-Louis; El Khoury, Gebrine
2010-03-01
Transapical aortic valve implantation requires puncture of the left ventricle apex and insertion of a 32-French delivery sheath. A critical step in the procedure consists of secure closure of the ventricular apex. We describe 2 cases of apical rupture of 42 transapical aortic valve implantations. Furthermore, we describe the use of a newly designed single circular Teflon pledget that can help to avoid this complication. This pledget provides a more secure and uniform shrinkage of the entire apex to close the defect left by the delivery sheath.
45 CFR 16.7 - The first steps in the appeal process: The notice of appeal and the Board's response.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 45 Public Welfare 1 2010-10-01 2010-10-01 false The first steps in the appeal process: The notice... SERVICES GENERAL ADMINISTRATION PROCEDURES OF THE DEPARTMENTAL GRANT APPEALS BOARD § 16.7 The first steps... of these procedures, and advise the appellant of the next steps. The Board will also send a copy of...
Gehrke, Sergio Alexandre; Bettach, Raphaél; Taschieri, Silvio; Boukhris, Gilles; Corbella, Stefano; Del Fabbro, Massimo
2015-08-01
The study aims to test the hypothesis of no differences in temperature variation by using a single bur for implant site preparation as compared with conventional drilling sequence using multiple burs with incremental diameter. Synthetic blocks of bone (type I density) were used for drilling procedures. Group 1 and Group 2 - drilling with three consecutive burs for a 4.1 mm cylindrical implant and for a 4.3 mm conical implant, respectively; Group 3 - drilling with a single bur for a 4.2 mm conical implant. For each group, 20 drilling procedures were performed without irrigation and 20 with external irrigation. The temperature in the cortical bone during osteotomy for implant site preparation was measured through a thermocouple. The mean temperatures and standard deviations for the drilling without irrigation were: 25.5 ± 1.24°C for Group 1; 28.1 ± 1.76°C for Group 2; 26.5 ± 1.79°C for Group 3. Considering the drilling with irrigation, the mean values and standard deviations were: 20.4 ± 1.17°C for Group 1; 22.2 ± 1.38°C for Group 2; 20.2 ± 0.83°C for Group 3. Groups 1 and 3 yielded similar results, while Group 2 displayed significantly higher temperature increase than the other two groups. The single bur drilling protocol did not produce greater bone heating than the conventional protocol and may be considered a safe procedure. © 2013 Wiley Periodicals, Inc.
Livingston, Michael H.; Pepe, Daniel; Jones, Sarah; Bütter, Andreana; Merritt, Neil H.
2015-01-01
Background This study describes our experience with the placement of a skin-level gastrostomy device (MIC-KEY) in a single procedure. Methods We identified infants, children and young adults who underwent laparoscopic-assisted percutaneous endoscopic gastrostomy (LAPEG) tube insertion between October 2009 and June 2013. The steps of this procedure include upper endoscopy, single-port laparoscopy, gastropexy via percutaneous T-fasteners and placement of a skin-level gastrostomy device (MIC-KEY) using a “push” technique with a tear-away sheath. Results We included 92 patients in our study. Mean age was 3.7 years (range 3 wk–5 yr), and mean weight was 11.2 (range 2.8–54) kg. Median procedural time was 20 (range 12–76) minutes. Total median duration for the most recent 25 procedures was lower than that of the first 25 (62 v. 79 min, p = 0.004). There were no intraoperative complications or conversions to open surgery. Postoperative complications were observed in 6 (6.5%) patients. Three retained T-fasteners were assessed endoscopically (n = 1) or removed via local excision (n = 2). Two patients experienced early dislodged feeding tubes that were replaced via interventional radiology (n = 1) or repeat LAPEG (n = 1). There was also 1 intra-abdominal fluid collection that was drained percutaneously but ultimately required a laparotomy and washout. There were no major complications in the most recent 50 procedures. Conclusion Our results suggest that LAPEG is a safe, minimally invasive procedure for infants, children and young adults. This approach allows for immediate use of a skin-level gastrostomy device without the need for postoperative tube exchanges. PMID:26204365
Sullivan, Maura E; Ortega, Adrian; Wasserberg, Nir; Kaufman, Howard; Nyquist, Julie; Clark, Richard
2008-01-01
The purpose of this study was to determine if a cognitive task analysis (CTA) could capture steps and decision points that were not articulated during traditional teaching of a colonoscopy. Three expert colorectal surgeons were videotaped performing a colonoscopy. After the videotapes were transcribed, the experts participated in a CTA. A 26-step procedural checklist and a 16-step cognitive demands table was created by using information obtained in the CTA. The videotape transcriptions were transposed onto the procedural checklist and cognitive demands table to identify steps and decision points that were omitted during traditional teaching. Surgeon A described 50% of "how-to" steps and 43% of decision points. Surgeon B described 30% of steps and 25% of decisions. Surgeon C described 26% of steps and 38% of cognitive decisions. By using CTA, we were able to identify relevant steps and decision points that were omitted during traditional teaching by all 3 experts.
Bentaleb, El Mehdi; Abid, Mohammed; El Messaoudi, My Driss; Lakssir, Brahim; Ressami, El Mostafa; Amzazi, Saaïd; Sefrioui, Hassan; Ait Benhassou, Hassan
2016-09-27
Tuberculosis (TB) is a major global health problem and remains the leading cause of morbidity and mortality in developing countries. Routinely used TB diagnostic methods, in most endemic areas, are time-consuming, often less-sensitive, expensive and inaccessible to most patients. Therefore, there is an urgent need for the development of early, easy to use and effective diagnosis tools of TB, which can be effectively integrated into resource limited settings, to anticipate the early treatment and limit further spread of the disease. Over the last decade, Loop-mediated isothermal amplification (LAMP) assays have become a powerful tool for rapid diagnosis of infectious diseases because of the simplicity of device requirements. Indeed, LAMP is a simple, quick and cost effective Isothermal Nucleic Acid Amplification diagnostic test (INAAT) that has the potential to be used in TB endemic settings of resource-poor countries. In the present study, we have developed a simple and rapid TB molecular diagnostic test using a Single-Step Loop-mediated isothermal DNA amplification (SS-LAMP) method for the detection of Mycobacterium tuberculosis complex (MTBC) strains, with a simplified sample preparation procedure, eliminating DNA extraction prior to LAMP amplification, DNA initial denaturation and enzymatic inactivation steps during the amplification process. To perform our in-house SS-LAMP assay, a set of six specific primers was specifically designed to recognize eight distinct regions on the MTBC species-specific repetitive insertion sequence 6110 (IS6110). The amplification of the targeted DNA was carried out under isothermal conditions at 65 °C within 1 h. Our protocol was firstly optimized using 60 of confirmed MTBC isolates and a recombinant pGEMeasy-IS6110 vector for sensitivity testing. Thereafter, the assay was evaluated on liquefied sputum specimens collected from 157 Moroccan patients suspected of having TB. Our SS-LAMP developed assay was able to detect MTBC DNA directly from liquefied sputum samples without any prior DNA extraction, denaturation nor the final enzymatic inactivation step. When compared to routinely used Löwenstein Jensen (LJ) Culture method, our SS-LAMP assay is rapid and showed specificity and sensitivity of 99.14 % and 82.93 % respectively which are within the international standards. In addition, the limit of detection of our assay was found to be as little as 10 copies of bacterial DNA. To our knowledge, this is the first study using a single step LAMP (SS-LAMP) procedure as a rapid, easy to perform and cost effective testing for TB early detection. This innovative assay could be suitable for low-income countries with restricted health equipment facilities.
Fisher, E R; Sass, R; Fisher, B
1985-09-01
Investigation of the biologic significance of delay between biopsy and mastectomy was performed upon women with invasive carcinoma of the breast in protocol four of the NSABP. Since the period of delay was two weeks or less in approximately 75 per cent, no comment concerning the possible effects of longer periods can be made. Life table analyses failed to reveal any difference in ten year survival rates between patients undergoing radical mastectomy management by the one and two step procedures. Similarly, no difference in adjusted ten year survival rate was observed between women managed by the two step procedure who did or did not have residual tumor identified in the mastectomy specimen after the first step or biopsy. Importantly, the clinical or pathologic stages, sizes of tumor or histologic grades were similar in women managed by the one and two step procedures minimizing selection bias. The material used also allowed for study of the possible causative role of biopsy of the breast on the development of sinus histiocytosis in regional axillary lymph nodes. No difference in degree or types of this nodal reaction could be discerned in the lymph nodes of the mastectomy specimens obtained from patients who had undergone the one and two step procedures. This finding indicates that nodal sinus histiocytosis is indeed related to the neoplastic process, albeit in an undefined manner, rather than the trauma of biopsy per se as has been suggested. These results do not invalidate the use of the one step procedure in the management of patients with carcinoma of the breast. Indeed, it is highly likely that it will be commonly used now that breast-conserving operations appear to represent a viable alternative modality for the primary surgical treatment of carcinoma of the breast. Yet, it is apparent that the one step procedure will be performed for technical and practical rather than biologic reasons.
Limits of acceptable change and natural resources planning: when is LAC useful, when is it not?
David N. Cole; Stephen F. McCool
1997-01-01
There are ways to improve the LAC process and its implementational procedures. One significant procedural modification is the addition of a new step. This step â which becomes the first step in the process â involves more explicitly defining goals and desired conditions. For other steps in the process, clarifications of concept and terminology are advanced, as are...
Pressure estimation from single-snapshot tomographic PIV in a turbulent boundary layer
NASA Astrophysics Data System (ADS)
Schneiders, Jan F. G.; Pröbsting, Stefan; Dwight, Richard P.; van Oudheusden, Bas W.; Scarano, Fulvio
2016-04-01
A method is proposed to determine the instantaneous pressure field from a single tomographic PIV velocity snapshot and is applied to a flat-plate turbulent boundary layer. The main concept behind the single-snapshot pressure evaluation method is to approximate the flow acceleration using the vorticity transport equation. The vorticity field calculated from the measured instantaneous velocity is advanced over a single integration time step using the vortex-in-cell (VIC) technique to update the vorticity field, after which the temporal derivative and material derivative of velocity are evaluated. The pressure in the measurement volume is subsequently evaluated by solving a Poisson equation. The procedure is validated considering data from a turbulent boundary layer experiment, obtained with time-resolved tomographic PIV at 10 kHz, where an independent surface pressure fluctuation measurement is made by a microphone. The cross-correlation coefficient of the surface pressure fluctuations calculated by the single-snapshot pressure method with respect to the microphone measurements is calculated and compared to that obtained using time-resolved pressure-from-PIV, which is regarded as benchmark. The single-snapshot procedure returns a cross-correlation comparable to the best result obtained by time-resolved PIV, which uses a nine-point time kernel. When the kernel of the time-resolved approach is reduced to three measurements, the single-snapshot method yields approximately 30 % higher correlation. Use of the method should be cautioned when the contributions to fluctuating pressure from outside the measurement volume are significant. The study illustrates the potential for simplifying the hardware configurations (e.g. high-speed PIV or dual PIV) required to determine instantaneous pressure from tomographic PIV.
ERIC Educational Resources Information Center
West, Alfred W.
This is the third in a series of documents developed by the National Training and Operational Technology Center describing operational control procedures for the activated sludge process used in wastewater treatment. This document deals with the calculation procedures associated with a step-feed process. Illustrations and examples are included to…
Standardizing bimanual vaginal examination using cognitive task analysis.
Plumptre, Isabella; Mulki, Omar; Granados, Alejandro; Gayle, Claudine; Ahmed, Shahla; Low-Beer, Naomi; Higham, Jenny; Bello, Fernando
2017-10-01
To create a standardized universal list of procedural steps for bimanual vaginal examination (BVE) for teaching, assessment, and simulator development. This observational study, conducted from June-July 2012 and July-December 2014, collected video data of 10 expert clinicians performing BVE in a nonclinical environment. Video data were analyzed to produce a cognitive task analysis (CTA) of the examination steps performed. The CTA was further refined through structured interviews to make it suitable for teaching or assessment. It was validated through its use as a procedural examination checklist to rate expert clinician performance. BVE was deconstructed into 88 detailed steps outlining the complete examination process. These initial 88 steps were reduced to 35 by focusing on the unseen internal examination, then further refined through interviews with five experts into 30 essential procedural steps, five of which are additional steps if pathology is suspected. Using the CTA as a procedural checklist, the mean number of steps performed and/or verbalized was 21.6 ± 3.12 (72% ± 10.4%; range, 15.9-27.9, 53%-93%). This approach identified 30 essential steps for performing BVE, producing a new technique and standardized tool for teaching, assessment, and simulator development. © 2017 International Federation of Gynecology and Obstetrics.
Save the last dance for me: unwanted serial position effects in jury evaluations.
Bruine de Bruin, Wändi
2005-03-01
Whenever competing options are considered in sequence, their evaluations may be affected by order of appearance. Such serial position effects would threaten the fairness of competitions using jury evaluations. Randomization cannot reduce potential order effects, but it does give candidates an equal chance of being assigned to preferred serial positions. Whether, or what, serial position effects emerge may depend on the cognitive demands of the judgment task. In end-of-sequence procedures, final scores are not given until all candidates have performed, possibly burdening judges' memory. If judges' evaluations are based on how well they remember performances, serial position effects may resemble those found with free recall. Candidates may also be evaluated step-by-step, immediately after each performance. This procedure should not burden memory, though it may produce different serial position effects. Yet, this paper reports similar serial position effects with end-of-sequence and step-by-step procedures used for the Eurovision Song Contest: Ratings increased with serial position. The linear order effect was replicated in the step-by-step judgments of World and European Figure Skating Contests. It is proposed that, independent of the evaluation procedure, judges' initial impressions of sequentially appearing candidates may be formed step-by-step, yielding serial position effects.
Teaching People and Machines to Enhance Images
NASA Astrophysics Data System (ADS)
Berthouzoz, Floraine Sara Martianne
Procedural tasks such as following a recipe or editing an image are very common. They require a person to execute a sequence of operations (e.g. chop onions, or sharpen the image) in order to achieve the goal of the task. People commonly use step-by-step tutorials to learn these tasks. We focus on software tutorials, more specifically photo manipulation tutorials, and present a set of tools and techniques to help people learn, compare and automate photo manipulation procedures. We describe three different systems that are each designed to help with a different stage in acquiring procedural knowledge. Today, people primarily rely on hand-crafted tutorials in books and on websites to learn photo manipulation procedures. However, putting together a high quality step-by-step tutorial is a time-consuming process. As a consequence, many online tutorials are poorly designed which can lead to confusion and slow down the learning process. We present a demonstration-based system for automatically generating succinct step-by-step visual tutorials of photo manipulations. An author first demonstrates the manipulation using an instrumented version of GIMP (GNU Image Manipulation Program) that records all changes in interface and application state. From the example recording, our system automatically generates tutorials that illustrate the manipulation using images, text, and annotations. It leverages automated image labeling (recognition of facial features and outdoor scene structures in our implementation) to generate more precise text descriptions of many of the steps in the tutorials. A user study finds that our tutorials are effective for learning the steps of a procedure; users are 20-44% faster and make 60-95% fewer errors when using our tutorials than when using screencapture video tutorials or hand-designed tutorials. We also demonstrate a new interface that allows learners to navigate, explore and compare large collections (i.e. thousands) of photo manipulation tutorials based on their command-level structure. Sites such as tutorialized.com or good-tutorials.com collect tens of thousands of photo manipulation tutorials. These collections typically contain many different tutorials for the same task. For example, there are many different tutorials that describe how to recolor the hair of a person in an image. Learners often want to compare these tutorials to understand the different ways a task can be done. They may also want to identify common strategies that are used across tutorials for a variety of tasks. However, the large number of tutorials in these collections and their inconsistent formats can make it difficult for users to systematically explore and compare them. Current tutorial collections do not exploit the underlying command-level structure of tutorials, and to explore the collection users have to either page through long lists of tutorial titles or perform keyword searches on the natural language tutorial text. We present a new browsing interface to help learners navigate, explore and compare collections of photo manipulation tutorials based on their command-level structure. Our browser indexes tutorials by their commands, identifies common strategies within the tutorial collection, and highlights the similarities and differences between sets of tutorials that execute the same task. User feedback suggests that our interface is easy to understand and use, and that users find command-level browsing to be useful for exploring large tutorial collections. They strongly preferred to explore tutorial collections with our browser over keyword search. Finally, we present a framework for generating content-adaptive macros (programs) that can transfer complex photo manipulation procedures to new target images. After learners master a photo manipulation procedure, they often repeatedly apply it to multiple images. For example, they might routinely apply the same vignetting effect to all their photographs. This process can be very tedious especially for procedures that involve many steps. While image manipulation programs provide basic macro authoring tools that allow users to record and then replay a sequence of operations, these macros are very brittle and cannot adapt to new images. We present a more comprehensive approach for generating content-adaptive macros that can automatically transfer operations to new target images. To create these macro, we make use of multiple training demonstrations. Specifically, we use automated image labeling and machine learning techniques to to adapt the parameters of each operation to the new image content. We show that our framework is able to learn a large class of the most commonly-used manipulations using as few as 20 training demonstrations. Our content-adaptive macros allow users to transfer photo manipulation procedures with a single button click and thereby significantly simplify repetitive procedures.
NASA Astrophysics Data System (ADS)
Suryono, T. J.; Gofuku, A.
2018-02-01
One of the important thing in the mitigation of accidents in nuclear power plant accidents is time management. The accidents should be resolved as soon as possible in order to prevent the core melting and the release of radioactive material to the environment. In this case, operators should follow the emergency operating procedure related with the accident, in step by step order and in allowable time. Nowadays, the advanced main control rooms are equipped with computer-based procedures (CBPs) which is make it easier for operators to do their tasks of monitoring and controlling the reactor. However, most of the CBPs do not include the time remaining display feature which informs operators of time available for them to execute procedure steps and warns them if the they reach the time limit. Furthermore, the feature will increase the awareness of operators about their current situation in the procedure. This paper investigates this issue. The simplified of emergency operating procedure (EOP) of steam generator tube rupture (SGTR) accident of PWR plant is applied. In addition, the sequence of actions on each step of the procedure is modelled using multilevel flow modelling (MFM) and influenced propagation rule. The prediction of action time on each step is acquired based on similar case accidents and the Support Vector Regression. The derived time will be processed and then displayed on a CBP user interface.
Improved enteral tolerance following step procedure: systematic literature review and meta-analysis.
Fernandes, Melissa A; Usatin, Danielle; Allen, Isabel E; Rhee, Sue; Vu, Lan
2016-10-01
Surgical management of children with short bowel syndrome (SBS) changed with the introduction of the serial transverse enteroplasty procedure (STEP). We conducted a systematic review and meta-analysis using MEDLINE and SCOPUS to determine if children with SBS had improved enteral tolerance following STEP. Studies were included if information about a child's pre- and post-STEP enteral tolerance was provided. A random effects meta-analysis provided a summary estimate of the proportion of children with enteral tolerance increase following STEP. From 766 abstracts, seven case series involving 86 children were included. Mean percent tolerance of enteral nutrition improved from 35.1 to 69.5. Sixteen children had no enteral improvement following STEP. A summary estimate showed that 87 % (95 % CI 77-95 %) of children who underwent STEP had an increase in enteral tolerance. Compilation of the literature supports the belief that SBS subjects' enteral tolerance improves following STEP. Enteral nutritional tolerance is a measure of efficacy of STEP and should be presented as a primary or secondary outcome. By standardizing data collection on children undergoing STEP procedure, better determination of nutritional benefit from STEP can be ascertained.
2012-01-01
Background A single-step blending approach allows genomic prediction using information of genotyped and non-genotyped animals simultaneously. However, the combined relationship matrix in a single-step method may need to be adjusted because marker-based and pedigree-based relationship matrices may not be on the same scale. The same may apply when a GBLUP model includes both genomic breeding values and residual polygenic effects. The objective of this study was to compare single-step blending methods and GBLUP methods with and without adjustment of the genomic relationship matrix for genomic prediction of 16 traits in the Nordic Holstein population. Methods The data consisted of de-regressed proofs (DRP) for 5 214 genotyped and 9 374 non-genotyped bulls. The bulls were divided into a training and a validation population by birth date, October 1, 2001. Five approaches for genomic prediction were used: 1) a simple GBLUP method, 2) a GBLUP method with a polygenic effect, 3) an adjusted GBLUP method with a polygenic effect, 4) a single-step blending method, and 5) an adjusted single-step blending method. In the adjusted GBLUP and single-step methods, the genomic relationship matrix was adjusted for the difference of scale between the genomic and the pedigree relationship matrices. A set of weights on the pedigree relationship matrix (ranging from 0.05 to 0.40) was used to build the combined relationship matrix in the single-step blending method and the GBLUP method with a polygenetic effect. Results Averaged over the 16 traits, reliabilities of genomic breeding values predicted using the GBLUP method with a polygenic effect (relative weight of 0.20) were 0.3% higher than reliabilities from the simple GBLUP method (without a polygenic effect). The adjusted single-step blending and original single-step blending methods (relative weight of 0.20) had average reliabilities that were 2.1% and 1.8% higher than the simple GBLUP method, respectively. In addition, the GBLUP method with a polygenic effect led to less bias of genomic predictions than the simple GBLUP method, and both single-step blending methods yielded less bias of predictions than all GBLUP methods. Conclusions The single-step blending method is an appealing approach for practical genomic prediction in dairy cattle. Genomic prediction from the single-step blending method can be improved by adjusting the scale of the genomic relationship matrix. PMID:22455934
Affinity Proteomics for Fast, Sensitive, Quantitative Analysis of Proteins in Plasma.
O'Grady, John P; Meyer, Kevin W; Poe, Derrick N
2017-01-01
The improving efficacy of many biological therapeutics and identification of low-level biomarkers are driving the analytical proteomics community to deal with extremely high levels of sample complexity relative to their analytes. Many protein quantitation and biomarker validation procedures utilize an immunoaffinity enrichment step to purify the sample and maximize the sensitivity of the corresponding liquid chromatography tandem mass spectrometry measurements. In order to generate surrogate peptides with better mass spectrometric properties, protein enrichment is followed by a proteolytic cleavage step. This is often a time-consuming multistep process. Presented here is a workflow which enables rapid protein enrichment and proteolytic cleavage to be performed in a single, easy-to-use reactor. Using this strategy Klotho, a low-abundance biomarker found in plasma, can be accurately quantitated using a protocol that takes under 5 h from start to finish.
NASA Astrophysics Data System (ADS)
Latrach, Chedia; Kchaou, Mourad; Guéguen, Hervé
2017-05-01
In this study, a decentralised output learning control strategy for a class of nonlinear interconnected systems is studied. Based on Takagi-Sugeno fuzzy (TS) model to approximate the considered interconnected nonlinear systems, a decentralised observer-based control scheme is designed to override the external disturbances such that the ? performance is achieved. The appealing attributes of this approach include: (1) the closed-loop system exhibits a robustness against nonlinear interconnections and external disturbance, (2) by one-step procedure, the gain matrices of observer and controller are obtained on a single step. In simulation results, the controller design is evaluated on the steering stability of a car where the nonlinear model describes the side slip, roll and yaw motions of the automotive vehicle equipped with four-wheel-steering and active suspension.
NASA Astrophysics Data System (ADS)
Franck, Bas A. M.; Dreschler, Wouter A.; Lyzenga, Johannes
2004-12-01
In this study we investigated the reliability and convergence characteristics of an adaptive multidirectional pattern search procedure, relative to a nonadaptive multidirectional pattern search procedure. The procedure was designed to optimize three speech-processing strategies. These comprise noise reduction, spectral enhancement, and spectral lift. The search is based on a paired-comparison paradigm, in which subjects evaluated the listening comfort of speech-in-noise fragments. The procedural and nonprocedural factors that influence the reliability and convergence of the procedure are studied using various test conditions. The test conditions combine different tests, initial settings, background noise types, and step size configurations. Seven normal hearing subjects participated in this study. The results indicate that the reliability of the optimization strategy may benefit from the use of an adaptive step size. Decreasing the step size increases accuracy, while increasing the step size can be beneficial to create clear perceptual differences in the comparisons. The reliability also depends on starting point, stop criterion, step size constraints, background noise, algorithms used, as well as the presence of drifting cues and suboptimal settings. There appears to be a trade-off between reliability and convergence, i.e., when the step size is enlarged the reliability improves, but the convergence deteriorates. .
Computational Phenotyping in Psychiatry: A Worked Example
2016-01-01
Abstract Computational psychiatry is a rapidly emerging field that uses model-based quantities to infer the behavioral and neuronal abnormalities that underlie psychopathology. If successful, this approach promises key insights into (pathological) brain function as well as a more mechanistic and quantitative approach to psychiatric nosology—structuring therapeutic interventions and predicting response and relapse. The basic procedure in computational psychiatry is to build a computational model that formalizes a behavioral or neuronal process. Measured behavioral (or neuronal) responses are then used to infer the model parameters of a single subject or a group of subjects. Here, we provide an illustrative overview over this process, starting from the modeling of choice behavior in a specific task, simulating data, and then inverting that model to estimate group effects. Finally, we illustrate cross-validation to assess whether between-subject variables (e.g., diagnosis) can be recovered successfully. Our worked example uses a simple two-step maze task and a model of choice behavior based on (active) inference and Markov decision processes. The procedural steps and routines we illustrate are not restricted to a specific field of research or particular computational model but can, in principle, be applied in many domains of computational psychiatry. PMID:27517087
Brambilla, Tatiana; Fiamengo, Barbara; Tinterri, Corrado; Testori, Alberto; Grassi, Massimo Maria; Sciarra, Amedeo; Abbate, Tommaso; Gatzemeier, Wolfgang; Roncalli, Massimo; Di Tommaso, Luca
2015-01-01
Sentinel lymph node (SLN) examination is a standard in breast cancer patients, with several methods employed along its 20 years history, the last one represented by one-step nucleic acid amplification (OSNA). The latter is a intra-operative molecular assay searching for CK19 mRNA as a surrogate of metastatic cells. Our 3 years experience with OSNA (1122 patients) showed results overlapping those recorded in the same institution with a morphological evaluation (930 patients) of SLN. In detail, the data of OSNA were almost identical to those observed with standard post-operative procedure in terms of patients with positive SLN (30%) and micrometastatic/macrometastatic involvement of SLN (respectively, 38–45 and 62–55%). By contrast, when OSNA was compared to the standard intraoperatory procedure, it was superior in terms of accuracy, prompting the use of this molecular assay as a very valid, and reproducible for intra-operative evaluation of SLN. Further possibilities prompting the use of OSNA range from adhesion to quality control programs, saving of medical time, ability to predict, during surgery, additional nodal metastasis, and molecular bio-banking. PMID:26131451
Brambilla, Tatiana; Fiamengo, Barbara; Tinterri, Corrado; Testori, Alberto; Grassi, Massimo Maria; Sciarra, Amedeo; Abbate, Tommaso; Gatzemeier, Wolfgang; Roncalli, Massimo; Di Tommaso, Luca
2015-01-01
Sentinel lymph node (SLN) examination is a standard in breast cancer patients, with several methods employed along its 20 years history, the last one represented by one-step nucleic acid amplification (OSNA). The latter is a intra-operative molecular assay searching for CK19 mRNA as a surrogate of metastatic cells. Our 3 years experience with OSNA (1122 patients) showed results overlapping those recorded in the same institution with a morphological evaluation (930 patients) of SLN. In detail, the data of OSNA were almost identical to those observed with standard post-operative procedure in terms of patients with positive SLN (30%) and micrometastatic/macrometastatic involvement of SLN (respectively, 38-45 and 62-55%). By contrast, when OSNA was compared to the standard intraoperatory procedure, it was superior in terms of accuracy, prompting the use of this molecular assay as a very valid, and reproducible for intra-operative evaluation of SLN. Further possibilities prompting the use of OSNA range from adhesion to quality control programs, saving of medical time, ability to predict, during surgery, additional nodal metastasis, and molecular bio-banking.
Computational Phenotyping in Psychiatry: A Worked Example.
Schwartenbeck, Philipp; Friston, Karl
2016-01-01
Computational psychiatry is a rapidly emerging field that uses model-based quantities to infer the behavioral and neuronal abnormalities that underlie psychopathology. If successful, this approach promises key insights into (pathological) brain function as well as a more mechanistic and quantitative approach to psychiatric nosology-structuring therapeutic interventions and predicting response and relapse. The basic procedure in computational psychiatry is to build a computational model that formalizes a behavioral or neuronal process. Measured behavioral (or neuronal) responses are then used to infer the model parameters of a single subject or a group of subjects. Here, we provide an illustrative overview over this process, starting from the modeling of choice behavior in a specific task, simulating data, and then inverting that model to estimate group effects. Finally, we illustrate cross-validation to assess whether between-subject variables (e.g., diagnosis) can be recovered successfully. Our worked example uses a simple two-step maze task and a model of choice behavior based on (active) inference and Markov decision processes. The procedural steps and routines we illustrate are not restricted to a specific field of research or particular computational model but can, in principle, be applied in many domains of computational psychiatry.
Gurram, Venkateshwarlu; Pottabathini, Narender; Garlapati, Ramesh; Chaudhary, Avinash B.; Patro, Balaram; Lakshman, Mahesh K.
2012-01-01
Reaction conditions for the C–C cross-coupling of O6-alkyl-2-bromo- and 2-chloroinosine derivatives with aryl-, hetaryl-, and alkylboronic acids were studied. Optimization experiments with silyl-protected 2-bromo-O6-methylinosine led to the identification of [PdCl2(dcpf)]/K3PO4 in 1,4-dioxane as the best condition for these reactions (dcpf = 1,1’-bis(dicyclohexylphosphino)ferrocene). Attempted O6-demethylation, as well as the replacement of the C-6 methoxy group by amines, was unsuccessful, which led to the consideration of Pd-cleavable groups such that C–C cross-coupling and O6-deprotection could be accomplished in a single step. Thus, inosine 2-chloro-O6-allylinosine was chosen as the substrate and, after re-evaluation of the cross-coupling conditions with 2-chloro-O6-methylinosine as a model substrate, one-step C–C cross-coupling/deprotection reactions were performed with the O6-allyl analogue. These reactions are the first such examples of a one-pot procedure for the modification and deprotection of purine nucleosides under C–C cross-coupling conditions. PMID:22570232
Burkovskiy, I; Lehmann, C; Jiang, C; Zhou, J
2016-11-01
Intravital microscopy of the intestine is a sophisticated technique that allows qualitative and quantitative in vivo observation of dynamic cellular interactions and blood flow at a high resolution. Physiological conditions of the animal and in particular of the observed organ, such as temperature and moisture are crucial for intravital imaging. Often, the microscopy stage with the animal or the organ of interest imposes limitations on how well the animal can be maintained. In addition, the access for additional oxygen supply or drug administration during the procedure is rather restricted. To address these limitations, we developed a novel intravital microscopy platform, allowing us to have improved access to the animal during the intravital microscopy procedure, as well as improved microenvironmental maintenance. The production process of this prototype platform is based on 3D printing of device parts in a single-step process. The simplicity of production and the advantages of this versatile and customizable design are shown and discussed in this paper. Our design potentially represents a major step forward in facilitating intestinal intravital imaging using fluorescent microscopy. © 2016 The Authors Journal of Microscopy © 2016 Royal Microscopical Society.
O'Connor, Thomas P
2015-12-01
The most widely used immunoassay configuration is the enzyme-linked immunosorbent assay (ELISA) because the procedure produces highly sensitive and specific results and generally is easy to use. By definition, ELISAs are immunoassays used to detect a substance (typically an antigen or antibody) in which an enzyme is attached (conjugated) to one of the reactants and an enzymatic reaction is used to amplify the signal if the substance is present. Optimized ELISAs include several steps that are performed in sequence using a defined protocol that typically includes application of sample and an enzyme-conjugated antibody or antigen to an immobilized reagent, followed by wash and enzyme reaction steps. The SNAP assay is an in-clinic device that performs each of the ELISA steps in a timed sequential fashion with little consumer interface. The components and mechanical mechanism of the assay device are described. Detailed descriptions of features of the assay, which minimize nonspecific binding and enhance the ability to read results from weak-positive samples, are given. Basic principles used in assays with fundamentally different reaction mechanisms, namely, antigen-detection, antibody-detection, and competitive assays are given. Applications of ELISA technology, which led to the development of several multianalyte SNAP tests capable of testing for up to 6 analytes using a single-sample and a single-SNAP device are described. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.
Multi-step Variable Height Photolithography for Valved Multilayer Microfluidic Devices.
Brower, Kara; White, Adam K; Fordyce, Polly M
2017-01-27
Microfluidic systems have enabled powerful new approaches to high-throughput biochemical and biological analysis. However, there remains a barrier to entry for non-specialists who would benefit greatly from the ability to develop their own microfluidic devices to address research questions. Particularly lacking has been the open dissemination of protocols related to photolithography, a key step in the development of a replica mold for the manufacture of polydimethylsiloxane (PDMS) devices. While the fabrication of single height silicon masters has been explored extensively in literature, fabrication steps for more complicated photolithography features necessary for many interesting device functionalities (such as feature rounding to make valve structures, multi-height single-mold patterning, or high aspect ratio definition) are often not explicitly outlined. Here, we provide a complete protocol for making multilayer microfluidic devices with valves and complex multi-height geometries, tunable for any application. These fabrication procedures are presented in the context of a microfluidic hydrogel bead synthesizer and demonstrate the production of droplets containing polyethylene glycol (PEG diacrylate) and a photoinitiator that can be polymerized into solid beads. This protocol and accompanying discussion provide a foundation of design principles and fabrication methods that enables development of a wide variety of microfluidic devices. The details included here should allow non-specialists to design and fabricate novel devices, thereby bringing a host of recently developed technologies to their most exciting applications in biological laboratories.
An Improved Qualitative Analysis Procedure for Aluminum Subgroup Cations.
ERIC Educational Resources Information Center
Kistner, C. R.; Robinson, Patricia J.
1983-01-01
Describes a procedure for the qualitative analysis of aluminum subgroup cations designed to avoid failure to obtain lead or barium chromate precipitates or failure to report aluminum hydroxide when present (due to staining). Provides a flow chart and step-by-step explanation for the new procedure, indicating significantly improved student results.…
30 CFR 250.1709 - What are my well-control fluid requirements?
Code of Federal Regulations, 2014 CFR
2014-07-01
... kill-weight fluid from the wellbore and/or riser to an underbalanced state, you must obtain approval... displacing the kill-weight fluid and provide detailed step-by-step written procedures describing how you will... barriers, (c) BOP procedures you will use while displacing kill weight fluids, and (d) Procedures you will...
30 CFR 250.514 - Well-control fluids, equipment, and operations.
Code of Federal Regulations, 2013 CFR
2013-07-01
... displace kill-weight fluid from the wellbore and/or riser to an underbalanced state, you must obtain... displacing the kill-weight fluid and provide detailed step-by-step written procedures describing how you will... barriers, (3) BOP procedures you will use while displacing kill-weight fluids, and (4) Procedures you will...
30 CFR 250.514 - Well-control fluids, equipment, and operations.
Code of Federal Regulations, 2014 CFR
2014-07-01
... displace kill-weight fluid from the wellbore and/or riser to an underbalanced state, you must obtain... displacing the kill-weight fluid and provide detailed step-by-step written procedures describing how you will... barriers, (3) BOP procedures you will use while displacing kill-weight fluids, and (4) Procedures you will...
30 CFR 250.1709 - What are my well-control fluid requirements?
Code of Federal Regulations, 2013 CFR
2013-07-01
... kill-weight fluid from the wellbore and/or riser to an underbalanced state, you must obtain approval... displacing the kill-weight fluid and provide detailed step-by-step written procedures describing how you will... barriers, (c) BOP procedures you will use while displacing kill weight fluids, and (d) Procedures you will...
Wang, Amy; Robertson, John L; Holladay, Steven D; Tennant, Alan H; Lengi, Andrea J; Ahmed, S Ansar; Huckle, William R; Kligerman, Andrew D
2007-12-01
Urinary bladder transitional epithelium is the main site of bladder cancer, and the use of transitional cells to study carcinogenesis/genotoxicity is recommended over the use of whole bladders. Because the transitional epithelium is only a small fraction of the whole bladder, the alkaline single cell gel electrophoresis assay (Comet assay), which requires only a small number of cells per sample, is especially suitable for measuring DNA damage in transitional cells. However, existed procedures of cell collection did not yield transitional cells with a high purity, and pooling of samples was needed for Comet assay. The goal of this study was to develop an optimized protocol to evaluate DNA damage in the urinary bladder transitional epithelium. This was achieved by an enzymatic stripping method (trypsin-EDTA incubation plus gentle scraping) to selectively harvest transitional cells from rat bladders, and the use of the alkaline Comet assay to detect DNA strand breaks, alkaline labile sites, and DNA-protein crosslinks. Step by step procedures are reported here. Cells collected from a single rat bladder were sufficient for multiple Comet assays. With this new protocol, increases in DNA damage were detected in transitional cells after in vitro exposure to the positive control agents, hydrogen peroxide or formaldehyde. Repair of the induced DNA damage occurred within 4h. This indicated the capacity for DNA repair was maintained in the harvested cells. The new protocol provides a simple and inexpensive method to detect various types of DNA damage and to measure DNA damage repair in urinary bladder transitional cells.
Apostolopoulos, Alexandros; Lallos, Stergios; Mastrokalos, Dimitrios; Michos, Ioannis; Darras, Nikolaos; Tzomaki, Magda; Efstathopoulos, Nikolaos
2011-01-01
The objective of this study was to capture and analyze the kinetics and kinematics and determine the functional performance of the osteoarthritic knee after a posterior cruciate ligament (PCL) retaining total knee arthroplasty. Kinematic and kinetic gait analysis of level walking was performed in 20 subjects (12 female and 8 male) with knee ostoarthritis. These patients were free of any neurological diseases that could affect their normal gait. Mean age was 69.6 ± 6.6 years; mean height was 157.6 cm ± 7.6 cm; and mean weight was 77.2 ± 12.1 kg. Full body gait analyses were performed using the BIOKIN 3D motion analysis system before and 9 months after total knee arthroplasty procedures. Single-step ascending kinetic analyses and plantar pressure distribution analyses were also performed for all subjects. International Knee Society Scores (IKSSs) were also assessed pre- and postoperatively. Significant increases were noted postoperatively in average cadence (preoperative mean = 99.26, postoperative mean = 110.5; p < 0.004), step length (preoperative mean = 0.49, postoperative mean = 0.54; p < 0.01) , and walking velocity (preoperative mean = 0.78, preoperatively, postoperative mean = 0.99; p < 0.001). Decreases in stance duration percentage and knee adduction moment were also reported postoperatively. All patients showed a significant improvement of knee kinetics and kinematics after a PCL retaining total knee arthroplasty. Significant differences were found in the cadence, step length, stride length, and walk velocity postoperatively. IKSSs also significantly improved. Further research is warranted to determine the clinical relevance of these findings.
Schwartze, Jonas; Jansen, Lars; Schrom, Harald; Wolf, Klaus-Hendrik; Haux, Reinhold; Marschollek, Michael
2015-01-01
Current AAL environments focus on assisting a single person with seperated technologies. There is no interoperability between sub-domains in home environments, like building energy management or housing industry services. BASIS (Building Automation by a Scalable and Intelligent System) aims to integrate all sensors and actuators into a single, efficient home bus. First step is to create a semtically enriched data warehouse object model. We choose FHIR and built an object model mainly based on the Observation, Device and Location resources with minor extensions needed by AAL-foreign sub domains. FHIR turned out to be very flexible and complete for other home related sub-domains. The object model is implemented in a separated software-partition storing all structural and procedural data of BASIS.
Multiple-3D-object secure information system based on phase shifting method and single interference.
Li, Wei-Na; Shi, Chen-Xiao; Piao, Mei-Lan; Kim, Nam
2016-05-20
We propose a multiple-3D-object secure information system for encrypting multiple three-dimensional (3D) objects based on the three-step phase shifting method. During the decryption procedure, five phase functions (PFs) are decreased to three PFs, in comparison with our previous method, which implies that one cross beam splitter is utilized to implement the single decryption interference. Moreover, the advantages of the proposed scheme also include: each 3D object can be decrypted discretionarily without decrypting a series of other objects earlier; the quality of the decrypted slice image of each object is high according to the correlation coefficient values, none of which is lower than 0.95; no iterative algorithm is involved. The feasibility of the proposed scheme is demonstrated by computer simulation results.
H(2)- and H(infinity)-design tools for linear time-invariant systems
NASA Technical Reports Server (NTRS)
Ly, Uy-Loi
1989-01-01
Recent advances in optimal control have brought design techniques based on optimization of H(2) and H(infinity) norm criteria, closer to be attractive alternatives to single-loop design methods for linear time-variant systems. Significant steps forward in this technology are the deeper understanding of performance and robustness issues of these design procedures and means to perform design trade-offs. However acceptance of the technology is hindered by the lack of convenient design tools to exercise these powerful multivariable techniques, while still allowing single-loop design formulation. Presented is a unique computer tool for designing arbitrary low-order linear time-invarient controllers than encompasses both performance and robustness issues via the familiar H(2) and H(infinity) norm optimization. Application to disturbance rejection design for a commercial transport is demonstrated.
Specific test and evaluation plan
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hays, W.H.
1998-03-20
The purpose of this Specific Test and Evaluation Plan (STEP) is to provide a detailed written plan for the systematic testing of modifications made to the 241-AX-B Valve Pit by the W-314 Project. The STEP develops the outline for test procedures that verify the system`s performance to the established Project design criteria. The STEP is a lower tier document based on the W-314 Test and Evaluation Plan (TEP). Testing includes Validations and Verifications (e.g., Commercial Grade Item Dedication activities), Factory Acceptance Tests (FATs), installation tests and inspections, Construction Acceptance Tests (CATs), Acceptance Test Procedures (ATPs), Pre-Operational Test Procedures (POTPs), andmore » Operational Test Procedures (OTPs). It should be noted that POTPs are not required for testing of the transfer line addition. The STEP will be utilized in conjunction with the TEP for verification and validation.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Le, A; Jiang, S; Timmerman, R
Purpose: To demonstrate the feasibility of using CBCT in a real-time image guided radiation therapy (IGRT) for single fraction heterotopic ossification (HO) in patients after hip replacement. In this real-time procedure, all steps, from simulation, imaging, planning to treatment delivery, are performed at the treatment unit in one appointment time slot. This work promotes real-time treatment to create a paradigm shift in the single fraction radiation therapy. Methods: An integrated real-time IGRT for HO was developed and tested for radiation treatment of heterotopic ossification for patient after hip replacement. After CBCT images are acquired at the linac, and sent tomore » the treatment planning system, the physician determines the field and/or draws a block. Subsequently, a simple 2D AP/PA plan with prescription of 700 cGy is created on-the-fly for physician to review. Once the physician approves the plan, the patient is treated on the same simulation position. This real-time treatment requires the team of attending physician, physicist, therapists, and dosimetrist to work in harmony to achieve all the steps in a timely manner. Results: Ten patients have been treated with this real-time treatment, having the same beams arrangement treatment plan and prescription as our clinically regular CT-based 2D plans. The average time for these procedures are 52.9 ±10.7 minutes from the time patient entered the treatment room until s/he exited, and 37.7 ±8.6 minutes from starting CBCT until last beam delivered. Conclusion: The real-time IGRT for HO treatment has been tested and implemented to be a clinically accepted procedure. This one-time appointment greatly enhances the waiting time, especially when patients in high level of pain, and provides a convenient approach for the whole clinical staff. Other disease sites will be also tested with this new technology.« less
NASA Technical Reports Server (NTRS)
Hoff, N J; Libby, Paul A; Klein, Bertran
1946-01-01
This report deals with the calculation of the bending moments in and the distortions of fuselage rings upon which known concentrated and distributed loads are acting. In the procedure suggested, the ring is divided into a number of beams each having a constant radius of curvature. The forces and moments caused in the end sections of the beams by individual unit displacements of the end sections are listed in a table designated as the operations table in conformity with Southwell's nomenclature. The operations table and the external loads are equivalent to a set of linear equations. For their solution the following three procedures are presented: 1) Southwell's method of systematic relaxations. This is a step-by-step approximation procedure guided by the physical interpretation of the changes in the values of the unknown. 2) The growing unit procedure in which the individual beams are combined successively into beams of increasing length until finally the entire ring becomes a single beam. In each step of the procedure a set of not more than three simultaneous linear equations is solved. 3) Solution of the entire set of simultaneous equations by the methods of the matrix calculus. In order to demonstrate the manner in which the calculations may be carried out, the following numerical examples are worked out: 1) Curved beam with both its end sections rigidly fixed. The load is a concentrated force. 2) Egg-shape ring with symmetric concentrated loads. 3) Circular ring with antisymmetric concentrated loads and shear flow (torsion of the fuselage). 4) Same with V-braces incorporated in the ring. 5) Egg-shape ring with antisymmetric concentrated loads and shear flow (torsion of the fuselage). 6) Same with V-braces incorporated in the ring. The results of these calculations are checked, whenever possible, by calculations carried out according to known methods of analysis. The agreement is found to be good. The amount of work necessary for the solution of ring problems by the methods described in the present report is practically independent of the degree of redundancy of the structure. For this reason the methods are recommended for use particularly in problems of rings having one or more internal bracing elements.
Cabaleiro, Joe
2007-01-01
A key component of qualifying for accreditation with the Pharmacy Compounding Accreditation Board is having a set of comprehensive standard operating procedures that are being used by the pharmacy staff. The three criteria in standard operating procedures for which the Pharmacy Compounding Accreditation Board looks are: (1)written standard operating procedures; (2)standard operating procedures that reflect what the organization actualy does; and (3) whether the written standard operating procedures are implemented. Following specified steps in the preparation of standard operating procedures will result in procedures that meet Pharmacy Compounding Accreditation Board Requirements, thereby placing pharmacies one step closer to qualifying for accreditation.
Evaluation of procedures for quality assurance specifications
DOT National Transportation Integrated Search
2004-10-01
The objective of this project was to develop a comprehensive quality assurance (QA) manual, supported by scientific evidence and statistical theory, which provides step-by-step procedures and instructions for developing effective and efficient QA spe...
This Standard Operating Procedure (SOP) describes a new, rapid, and relatively inexpensive one step procedure which grinds the paint samples removed from the substrate and simultaneously quantitatively extracts the Pb from the paint in only one step in preparation for quantitativ...
A procedure for NEPA assessment of selenium hazards associated with mining
Dennis A. Lemly
2007-01-01
This paper gives step-by-step instructions for assessing aquatic selenium hazards associated with mining. The procedure was developed to provide the U.S. Forest Service with a proactive capability for determining the risk of selenium pollution when it reviews mine permit applications in accordance with the National Environmental Policy Act (NEPA). The procedural...
Comparison of Methods for Demonstrating Passage of Time When Using Computer-Based Video Prompting
ERIC Educational Resources Information Center
Mechling, Linda C.; Bryant, Kathryn J.; Spencer, Galen P.; Ayres, Kevin M.
2015-01-01
Two different video-based procedures for presenting the passage of time (how long a step lasts) were examined. The two procedures were presented within the framework of video prompting to promote independent multi-step task completion across four young adults with moderate intellectual disability. The two procedures demonstrating passage of the…
Practical issues in quantum-key-distribution postprocessing
NASA Astrophysics Data System (ADS)
Fung, Chi-Hang Fred; Ma, Xiongfeng; Chau, H. F.
2010-01-01
Quantum key distribution (QKD) is a secure key generation method between two distant parties by wisely exploiting properties of quantum mechanics. In QKD, experimental measurement outcomes on quantum states are transformed by the two parties to a secret key. This transformation is composed of many logical steps (as guided by security proofs), which together will ultimately determine the length of the final secret key and its security. We detail the procedure for performing such classical postprocessing taking into account practical concerns (including the finite-size effect and authentication and encryption for classical communications). This procedure is directly applicable to realistic QKD experiments and thus serves as a recipe that specifies what postprocessing operations are needed and what the security level is for certain lengths of the keys. Our result is applicable to the BB84 protocol with a single or entangled photon source.
Comparing the development of the multiplication of fractions in Turkish and American textbooks
NASA Astrophysics Data System (ADS)
Kar, Tuğrul; Güler, Gürsel; Şen, Ceylan; Özdemir, Ercan
2018-02-01
This study analyzed the methods used to teach the multiplication of fractions in Turkish and American textbooks. Two Turkish textbooks and two American textbooks, Everyday Mathematics (EM) and Connected Mathematics 3 (CM), were analyzed. The analyses focused on the content and the nature of the mathematical problems presented in the textbooks. The findings of the study showed that the American textbooks aimed at developing conceptual understanding first and then procedural fluency, whereas the Turkish textbooks aimed at developing both concurrently. The American textbooks provided more opportunities for different computational strategies. The solutions to most problems in all textbooks required a single computational step, a numerical answer, and procedural knowledge. Furthermore, compared with the Turkish textbooks, the American textbooks contained a greater number of problems that required high-level cognitive skills such as mathematical reasoning.
Mueller, D; Kulkarni, Harshad; Baum, Richard P; Odparlik, Andreas
2017-04-01
99m Tc-labeled MAA is commonly used for single photon emission computed tomography SPECT. In contrast, positron emission tomography/CT (PET/CT) delivers images with significantly higher resolution. The generator produced radionuclide 68 Ga is widely used for PET/CT imaging agents and 68 Ga-labeled MAA represents an attractive alternative to 99m Tc-labeled MAA. We report a simple and rapid NaCl based labeling procedure for the labeling of MAA with 68 Ga using a commercially available MAA labeling kit for 99m Tc. The procedure delivers 68 Ga-labeled MAA with a high specific activity and a high labeling efficiency (>99%). The synthesis does not require a final step of separation or the use of organic solvents. Copyright © 2017 Elsevier Ltd. All rights reserved.
A new approach of the synthesis of SiO 2 nanowires by using bulk copper foils as catalyst
Gomez-Martinez, A.; Márquez, F.; Morant, C.
2016-06-22
In this paper, a novel procedure for the growth of SiO 2 nanowires (SiO 2NWs) directly from polycrystalline copper foils is reported. The single-step synthesis procedure consists of a thermal treatment at 900°C without the need for additional catalysts. As a result, nanowires with an average diameter of 100 nm are synthesized. A systematic study undertaken at different stages of the SiO 2NWs growth confirmed the generation of nucleation centers on the Cu surface, as well as revealed the existence of an intermediate gaseous SiO species at the synthesis temperature. Lastly, on the basis of these evidences, the vapor-liquid-solid (VLS)more » route has been proposed as the mechanism responsible for the growth.« less
Lorenz, Matthew A.; Burant, Charles F.; Kennedy, Robert T.
2011-01-01
A simple, fast, and reproducible sample preparation procedure was developed for relative quantification of metabolites in adherent mammalian cells using the clonal β-cell line INS-1 as a model sample. The method was developed by evaluating the effect of different sample preparation procedures on high performance liquid chromatography- mass spectrometry quantification of 27 metabolites involved in glycolysis and the tricarboxylic acid cycle on a directed basis as well as for all detectable chromatographic features on an undirected basis. We demonstrate that a rapid water rinse step prior to quenching of metabolism reduces components that suppress electrospray ionization thereby increasing signal for 26 of 27 targeted metabolites and increasing total number of detected features from 237 to 452 with no detectable change of metabolite content. A novel quenching technique is employed which involves addition of liquid nitrogen directly to the culture dish and allows for samples to be stored at −80 °C for at least 7 d before extraction. Separation of quenching and extraction steps provides the benefit of increased experimental convenience and sample stability while maintaining metabolite content similar to techniques that employ simultaneous quenching and extraction with cold organic solvent. The extraction solvent 9:1 methanol: chloroform was found to provide superior performance over acetonitrile, ethanol, and methanol with respect to metabolite recovery and extract stability. Maximal recovery was achieved using a single rapid (~1 min) extraction step. The utility of this rapid preparation method (~5 min) was demonstrated through precise metabolite measurements (11% average relative standard deviation without internal standards) associated with step changes in glucose concentration that evoke insulin secretion in the clonal β-cell line INS-1. PMID:21456517
Project W-314 specific test and evaluation plan for AZ tank farm upgrades
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hays, W.H.
1998-08-12
The purpose of this Specific Test and Evaluation Plan (STEP) is to provide a detailed written plan for the systematic testing of modifications made by the addition of the SN-631 transfer line from the AZ-O1A pit to the AZ-02A pit by the W-314 Project. The STEP develops the outline for test procedures that verify the system`s performance to the established Project design criteria. The STEP is a lower tier document based on the W-314 Test and Evaluation P1 an (TEP). Testing includes Validations and Verifications (e.g., Commercial Grade Item Dedication activities, etc), Factory Tests and Inspections (FTIs), installation tests andmore » inspections, Construction Tests and Inspections (CTIs), Acceptance Test Procedures (ATPs), Pre-Operational Test Procedures (POTPs), and Operational Test Procedures (OTPs). The STEP will be utilized in conjunction with the TEP for verification and validation.« less
How to Create Videos for Extension Education: An Innovative Five-Step Procedure
ERIC Educational Resources Information Center
Dev, Dipti A.; Blitch, Kimberly A.; Hatton-Bowers, Holly; Ramsay, Samantha; Garcia, Aileen S.
2018-01-01
Although the benefits of using video as a learning tool in Extension programs are well known, less is understood about effective methods for creating videos. We present a five-step procedure for developing educational videos that focus on evidence-based practices, and we provide practical examples from our use of the five steps in creating a video…
Repetitive readout of a single electronic spin via quantum logic with nuclear spin ancillae.
Jiang, L; Hodges, J S; Maze, J R; Maurer, P; Taylor, J M; Cory, D G; Hemmer, P R; Walsworth, R L; Yacoby, A; Zibrov, A S; Lukin, M D
2009-10-09
Robust measurement of single quantum bits plays a key role in the realization of quantum computation and communication as well as in quantum metrology and sensing. We have implemented a method for the improved readout of single electronic spin qubits in solid-state systems. The method makes use of quantum logic operations on a system consisting of a single electronic spin and several proximal nuclear spin ancillae in order to repetitively readout the state of the electronic spin. Using coherent manipulation of a single nitrogen vacancy center in room-temperature diamond, full quantum control of an electronic-nuclear system consisting of up to three spins was achieved. We took advantage of a single nuclear-spin memory in order to obtain a 10-fold enhancement in the signal amplitude of the electronic spin readout. We also present a two-level, concatenated procedure to improve the readout by use of a pair of nuclear spin ancillae, an important step toward the realization of robust quantum information processors using electronic- and nuclear-spin qubits. Our technique can be used to improve the sensitivity and speed of spin-based nanoscale diamond magnetometers.
Knob, Radim; Hanson, Robert L; Tateoka, Olivia B; Wood, Ryan L; Guerrero-Arguero, Israel; Robison, Richard A; Pitt, William G; Woolley, Adam T
2018-05-21
Fast determination of antibiotic resistance is crucial in selecting appropriate treatment for sepsis patients, but current methods based on culture are time consuming. We are developing a microfluidic platform with a monolithic column modified with oligonucleotides designed for sequence-specific capture of target DNA related to the Klebsiella pneumoniae carbapenemase (KPC) gene. We developed a novel single-step monolith fabrication method with an acrydite-modified capture oligonucleotide in the polymerization mixture, enabling fast monolith preparation in a microfluidic channel using UV photopolymerization. These prepared columns had a threefold higher capacity compared to monoliths prepared in a multistep process involving Schiff-base DNA attachment. Conditions for denaturing, capture and fluorescence labeling using hybridization probes were optimized with synthetic 90-mer oligonucleotides. These procedures were applied for extraction of a PCR amplicon from the KPC antibiotic resistance gene in bacterial lysate obtained from a blood sample spiked with E. coli. The results showed similar eluted peak areas for KPC amplicon extracted from either hybridization buffer or bacterial lysate. Selective extraction of the KPC DNA was verified by real time PCR on eluted fractions. These results show great promise for application in an integrated microfluidic diagnostic system that combines upstream blood sample preparation and downstream single-molecule counting detection. Copyright © 2018 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yokoyama, Yoko; Shimizu, Akira; Okada, Etsuko
Highlights: Black-Right-Pointing-Pointer We developed new method to rapidly identify COL1A1-PDGFB fusion in DFSP. Black-Right-Pointing-Pointer New PCR method using a single primer pair detected COL1A1-PDGFB fusion in DFSP. Black-Right-Pointing-Pointer This is the first report of DFSP with a novel COL1A1 breakpoint in exon 5. -- Abstract: The detection of fusion transcripts of the collagen type 1{alpha}1 (COL1A1) and platelet-derived growth factor-BB (PDGFB) genes by genetic analysis has recognized as a reliable and valuable molecular tool for the diagnosis of dermatofibrosarcoma protuberans (DFSP). To detect the COL1A1-PDGFB fusion, almost previous reports performed reverse transcription polymerase chain reaction (RT-PCR) using multiplex forward primersmore » from COL1A1. However, it has possible technical difficulties with respect to the handling of multiple primers and reagents in the procedure. The objective of this study is to establish a rapid, easy, and efficient one-step method of PCR using only a single primer pair to detect the fusion transcripts of the COL1A1 and PDGFB in DFSP. To validate new method, we compared the results of RT-PCR in five patients of DFSP between the previous method using multiplex primers and our established one-step RT-PCR using a single primer pair. In all cases of DFSP, the COL1A1-PDGFB fusion was detected by both previous method and newly established one-step PCR. Importantly, we detected a novel COL1A1 breakpoint in exon 5. The newly developed method is valuable to rapidly identify COL1A1-PDGFB fusion transcripts in DFSP.« less
Recording human cortical population spikes non-invasively--An EEG tutorial.
Waterstraat, Gunnar; Fedele, Tommaso; Burghoff, Martin; Scheer, Hans-Jürgen; Curio, Gabriel
2015-07-30
Non-invasively recorded somatosensory high-frequency oscillations (sHFOs) evoked by electric nerve stimulation are markers of human cortical population spikes. Previously, their analysis was based on massive averaging of EEG responses. Advanced neurotechnology and optimized off-line analysis can enhance the signal-to-noise ratio of sHFOs, eventually enabling single-trial analysis. The rationale for developing dedicated low-noise EEG technology for sHFOs is unfolded. Detailed recording procedures and tailored analysis principles are explained step-by-step. Source codes in Matlab and Python are provided as supplementary material online. Combining synergistic hardware and analysis improvements, evoked sHFOs at around 600 Hz ('σ-bursts') can be studied in single-trials. Additionally, optimized spatial filters increase the signal-to-noise ratio of components at about 1 kHz ('κ-bursts') enabling their detection in non-invasive surface EEG. sHFOs offer a unique possibility to record evoked human cortical population spikes non-invasively. The experimental approaches and algorithms presented here enable also non-specialized EEG laboratories to combine measurements of conventional low-frequency EEG with the analysis of concomitant cortical population spike responses. Copyright © 2014 Elsevier B.V. All rights reserved.
[The stamp technique for direct composite restoration].
Perrin, Philippe; Zimmerli, Brigitte; Jacky, Daniel; Lussi, Adrian; Helbling, Christoph; Ramseyer, Simon
2013-01-01
The indications for direct resin composite restorations are nowadays extended due to the development of modern resin materials with improved material properties. However, there are still some difficulties regarding handling of resin composite material, especially in large restorations. The reconstruction of a functional and individual occlusion is difficult to achieve with direct application techniques. The aim of the present publication was to introduce a new "stamp"-technique for placing large composite restorations. The procedure of this "stamp"-technique is presented by three typical indications: large single-tooth restoration, occlusal rehabilitation of a compromised occlusal surface due to erosions and direct fibre-reinforced fixed partial denture. A step-by-step description of the technique and clinical figures illustrates the method. Large single-tooth restorations can be built-up with individual, two- piece silicone stamps. Large occlusal abrasive and/or erosive defects can be restored by copying the wax-up from the dental technician using the "stamp"-technique. Even fiber-reinforced resin-bonded fixed partial dentures can be formed with this intraoral technique with more precision and within a shorter treatment time. The presented "stamp"-technique facilitates the placement of large restoration with composite and can be recommended for the clinical use.
Brezar, Vedran; Ruffin, Nicolas; Lévy, Yves; Seddiki, Nabila
2014-09-01
Regulatory T cells (Tregs) are pivotal in preventing autoimmunity. They play a major but still ambiguous role in cancer and viral infections. Functional studies of human Tregs are often hampered by numerous technical difficulties arising from imperfections in isolating and depleting protocols, together with the usual low cell number available from clinical samples. We standardized a simple procedure (Single Step Method, SSM), based on magnetic beads technology, in which both depletion and isolation of human Tregs with high purities are simultaneously achieved. SSM is suitable when using low cell numbers either fresh or frozen from both patients and healthy individuals. It allows simultaneous Tregs isolation and depletion that can be used for further functional work to monitor suppressive function of isolated Tregs (in vitro suppression assay) and also effector IFN-γ responses of Tregs-depleted cell fraction (OX40 assay). To our knowledge, there is no accurate standardized method for Tregs isolation and depletion in a clinical context. SSM could thus be used and easily standardized across different laboratories. Copyright © 2014 Elsevier B.V. All rights reserved.
A Case Study of a Combat Aircraft’s Single Hit Vulnerability
1986-09-01
Survivability Life Cycle 21 3.2 Interfaces of the FMECA Process 27 3.3 Example FMEA Format 29 3.4 Example DMEA Matrix 33 3.5 Example Disablement Diagram 34...Typical Hi-Hi/Hi-Hi Mission 58 5.5 A-20 Conceptual Tactics 60 7.1 A-20 Fuel System 73 7.2 A-20 Hydraulics System 75 7.3 A-20 Flight Controls System 77 7.4...effect severity. The FMECA procedure is performed in two steps, (1) a Fail- ure Mode and Effects Analysis ( FMEA ) and (2) a Damage Mode and Effects
DOE Office of Scientific and Technical Information (OSTI.GOV)
Amygdalos, Michael A.; Haskal, Ziv J.; Cope, Constantin
Two patients with pancreatic malignancies presented with biliary obstruction which could not be treated from an endoscopic approach. Standard transhepatic biliary drainage was relatively contraindicated because of moderate ascites and coagulopathy related to underlying liver disease. In one patient, a transjugular, transvenous approach was used to deliver a Wallstent endoprosthesis across the distal common bile duct obstruction in a single step procedure. In the second case, a previously placed biliary Wallstent was revised with an additional stent from a similar approach. Transjugular biliary catheterization offers a valuable alternative approach for primary stent placement or revision in patients with contraindication tomore » standard transhepatic drainage.« less
ERIC Educational Resources Information Center
Petrasek, Al, Jr.
This guide describes the standard operating job procedures for the tertiary chemical treatment - lime precipitation process of wastewater treatment plants. Step-by-step instructions are given for pre-start up, start-up, continuous operation, and shut-down procedures. In addition, some theoretical material is presented along with some relevant…
ERIC Educational Resources Information Center
Deal, Gerald A.; Montgomery, James A.
This guide describes standard operating job procedures for the grit removal process of wastewater treatment plants. Step-by-step instructions are given for pre-start up inspection, start-up, continuous operation, and shut-down procedures. A description of the equipment used in the process is given. Some theoretical material is presented. (BB)
NASA Technical Reports Server (NTRS)
Gumbert, C. R.
1985-01-01
A transonic Wall-Interference Assessment/Correction (WIAC) procedure has been developed and verified for the 8- by 24-inch airfoil test section of the Langley 0.3-m Transonic Cryogenic Tunnel. This report is a user's manual for the correction procedure. It includes a listing of the computer procedure file as well as input for and results from a step-by-step sample case.
Proton irradiation of [18O]O2: production of [18F]F2 and [18F]F2 + [18F] OF2.
Bishop, A; Satyamurthy, N; Bida, G; Hendry, G; Phelps, M; Barrio, J R
1996-04-01
The production of 18F electrophilic reagents via the 18O(p,n)18F reaction has been investigated in small-volume target bodies made of aluminum, copper, gold-plated copper and nickel, having straight or conical bore shapes. Three irradiation protocols-single-step, two-step and modified two-step-were used for the recovery of the 18F activity. The single-step irradiation protocol was tested in all the target bodies. Based on the single-step performance, aluminum targets were utilized extensively in the investigation of the two-step and modified two-step irradiation protocols. With an 11-MeV cyclotron and using the two-step irradiation protocol, > 1Ci [18F]F2 was recovered reproducibly from an aluminum target body. Probable radical mechanisms for the formation of OF2 and FONO2 (fluorine nitrate) in the single-step and modified two-step targets are proposed based on the amount of ozone generated and the nitrogen impurity present in the target gases, respectively.
[Targeted methods for measuring patient satisfaction in a radiological center].
Maurer, M H; Stein, E; Schreiter, N F; Renz, D M; Poellinger, A
2010-11-01
To investigate two event-oriented methods for evaluating patient satisfaction with radiological services like outpatient computed tomography (CT) examinations. 159 patients (55% men, 45% women) were asked to complete a questionnaire to provide information about their satisfaction with their examination. At first, patients were asked to spontaneously recall notably positive and negative aspects (so-called "critical incidents", critical incident technique = CIT) of the examination. Subsequently a flow chart containing all single steps of the examination procedure was shown to all patients. They were asked to point out the positive and negative aspects they perceived at each step (so-called sequential incident technique = SIT). The CIT-based part of the questionnaire yielded 356 comments (183 positive and 173 negative), which were assigned to one of four categories: interaction of staff with patient, procedure and organization, CT examination, and overall setting of the examination. Significantly more detailed comments regarding individual aspects of the CT examination were elicited in the second part of the survey, which was based on the SIT. There were 1413 statements with a significantly higher number of positive comments (n = 939, 66%) versus negative comments (n = 474, 34%; p < 0.001). The critical and sequential incident techniques are suitable to measure the subjective satisfaction with the delivery of radiological services such as CT examinations. Positive comments confirm the adequacy of the existing procedures, while negative comments provide direct information about how service quality can be improved. © Georg Thieme Verlag KG Stuttgart · New York.
Carty, Christopher P; Cronin, Neil J; Lichtwark, Glen A; Mills, Peter M; Barrett, Rod S
2012-12-01
Studying recovery responses to loss of balance may help to explain why older adults are susceptible to falls. The purpose of the present study was to assess whether male and female older adults, that use a single or multiple step recovery strategy, differ in the proportion of lower limb strength used and power produced during the stepping phase of balance recovery. Eighty-four community-dwelling older adults (47 men, 37 women) participated in the study. Isometric strength of the ankle, knee and hip joint flexors and extensors was assessed using a dynamometer. Loss of balance was induced by releasing participants from a static forward lean (4 trials at each of 3 forward lean angles). Participants were instructed to recover with a single step and were subsequently classified as using a single or multiple step recovery strategy for each trial. (1) Females were weaker than males and the proportion of females that were able to recover with a single step were lower than for males at each lean magnitude. (2) Multiple compared to single steppers used a significantly higher proportion of their hip extension strength and produced less knee and ankle joint peak power during stepping, at the intermediate lean angle. Strength deficits in female compared to male participants may explain why a lower proportion of female participants were able to recover with a single step. The inability to generate sufficient power in the stepping limb appears to be a limiting factor in single step recovery from forward loss of balance. Crown Copyright © 2012. Published by Elsevier Ltd. All rights reserved.
Absolute Paleointensity Techniques: Developments in the Last 10 Years (Invited)
NASA Astrophysics Data System (ADS)
Bowles, J. A.; Brown, M. C.
2009-12-01
The ability to determine variations in absolute intensity of the Earth’s paleomagnetic field has greatly enhanced our understanding of geodynamo processes, including secular variation and field reversals. Igneous rocks and baked clay artifacts that carry a thermal remanence (TRM) have allowed us to study field variations over timescales ranging from decades to billions of years. All absolute paleointensity techniques are fundamentally based on repeating the natural process by which the sample acquired its magnetization, i.e. a laboratory TRM is acquired in a controlled field, and the ratio of the natural TRM to that acquired in the laboratory is directly proportional to the ancient field. Techniques for recovering paleointensity have evolved since the 1930s from relatively unsophisticated (but revolutionary for their time) single step remagnetizations to the various complicated, multi-step procedures in use today. These procedures can be broadly grouped into two categories: 1) “Thellier-type” experiments that step-wise heat samples at a series of temperatures up to the maximum unblocking temperature of the sample, progressively removing the natural remanence (NRM) and acquiring a laboratory-induced TRM; and 2) “Shaw-type” experiments that combine alternating field demagnetization of the NRM and laboratory TRM with a single heating to a temperature above the sample’s Curie temperature, acquiring a total TRM in one step. Many modifications to these techniques have been developed over the years with the goal of identifying and/or accommodating non-ideal behavior, such as alteration and multi-domain (MD) remanence, which may lead to inaccurate paleofield estimates. From a technological standpoint, perhaps the most significant development in the last decade is the use of microwave (de)magnetization in both Thellier-type and Shaw-type experiments. By using microwaves to directly generate spin waves within the magnetic grains (rather than using phonons generated by heating, which then exchange energy with the magnetic system), a TRM can be acquired with minimal heating of the bulk sample, thus potentially minimizing sample alteration. The theory of TRM acquisition is best developed for single-domain (SD) grains, and most paleointensity techniques are predicated on the assumption that the remanence is carried predominantly by SD material. Because the vast majority of geological materials are characterized by a larger magnetic grain size, efforts to expand paleointensity studies over the past decade have focused on developing TRM theories and paleointensity methods for pseudo-single-domain (PSD) and MD samples. Other workers have been exploring the potential of SD materials that were not traditionally used in paleointensity studies, such as ash flow tuffs, submarine basaltic glass, and single silicate crystals with magnetite inclusions. The latter has the potential to shed light on early Earth processes, given that the fine-grained inclusions may be resistant to alteration over long time scales. We will review the major paleointensity techniques in use today, with special attention paid to the advantages and disadvantages of each. Techniques will be illustrated with examples highlighting new paleointensity applications to geologic processes at a variety of timescales.
Laboratory procedures to generate viral metagenomes.
Thurber, Rebecca V; Haynes, Matthew; Breitbart, Mya; Wegley, Linda; Rohwer, Forest
2009-01-01
This collection of laboratory protocols describes the steps to collect viruses from various samples with the specific aim of generating viral metagenome sequence libraries (viromes). Viral metagenomics, the study of uncultured viral nucleic acid sequences from different biomes, relies on several concentration, purification, extraction, sequencing and heuristic bioinformatic methods. No single technique can provide an all-inclusive approach, and therefore the protocols presented here will be discussed in terms of hypothetical projects. However, care must be taken to individualize each step depending on the source and type of viral-particles. This protocol is a description of the processes we have successfully used to: (i) concentrate viral particles from various types of samples, (ii) eliminate contaminating cells and free nucleic acids and (iii) extract, amplify and purify viral nucleic acids. Overall, a sample can be processed to isolate viral nucleic acids suitable for high-throughput sequencing in approximately 1 week.
Huang, Kai; Demadrille, Renaud; Silly, Mathieu G; Sirotti, Fausto; Reiss, Peter; Renault, Olivier
2010-08-24
High-energy resolution photoelectron spectroscopy (DeltaE < 200 meV) is used to investigate the internal structure of semiconductor quantum dots containing low Z-contrast elements. In InP/ZnS core/shell nanocrystals synthesized using a single-step procedure (core and shell precursors added at the same time), a homogeneously alloyed InPZnS core structure is evidenced by quantitative analysis of their In3d(5/2) spectra recorded at variable excitation energy. When using a two-step method (core InP nanocrystal synthesis followed by subsequent ZnS shell growth), XPS analysis reveals a graded core/shell interface. We demonstrate the existence of In-S and S(x)-In-P(1-x) bonding states in both types of InP/ZnS nanocrystals, which allows a refined view on the underlying reaction mechanisms.
A coupled weather generator - rainfall-runoff approach on hourly time steps for flood risk analysis
NASA Astrophysics Data System (ADS)
Winter, Benjamin; Schneeberger, Klaus; Dung Nguyen, Viet; Vorogushyn, Sergiy; Huttenlau, Matthias; Merz, Bruno; Stötter, Johann
2017-04-01
The evaluation of potential monetary damage of flooding is an essential part of flood risk management. One possibility to estimate the monetary risk is to analyze long time series of observed flood events and their corresponding damages. In reality, however, only few flood events are documented. This limitation can be overcome by the generation of a set of synthetic, physically and spatial plausible flood events and subsequently the estimation of the resulting monetary damages. In the present work, a set of synthetic flood events is generated by a continuous rainfall-runoff simulation in combination with a coupled weather generator and temporal disaggregation procedure for the study area of Vorarlberg (Austria). Most flood risk studies focus on daily time steps, however, the mesoscale alpine study area is characterized by short concentration times, leading to large differences between daily mean and daily maximum discharge. Accordingly, an hourly time step is needed for the simulations. The hourly metrological input for the rainfall-runoff model is generated in a two-step approach. A synthetic daily dataset is generated by a multivariate and multisite weather generator and subsequently disaggregated to hourly time steps with a k-Nearest-Neighbor model. Following the event generation procedure, the negative consequences of flooding are analyzed. The corresponding flood damage for each synthetic event is estimated by combining the synthetic discharge at representative points of the river network with a loss probability relation for each community in the study area. The loss probability relation is based on exposure and susceptibility analyses on a single object basis (residential buildings) for certain return periods. For these impact analyses official inundation maps of the study area are used. Finally, by analyzing the total event time series of damages, the expected annual damage or losses associated with a certain probability of occurrence can be estimated for the entire study area.
Two-step tunneling technique of deep brain stimulation extension wires-a description.
Fontaine, Denys; Vandersteen, Clair; Saleh, Christian; von Langsdorff, Daniel; Poissonnet, Gilles
2013-12-01
While a significant body of literature exists on the intracranial part of deep brain stimulation surgery, the equally important second part of the intervention related to the subcutaneous tunneling of deep brain stimulation extension wires is rarely described. The tunneling strategy can consist of a single passage of the extension wires from the frontal incision site to the subclavicular area, or of a two-step approach that adds a retro-auricular counter-incision. Each technique harbors the risk of intraoperative and postoperative complications. At our center, we perform a two-step tunneling procedure that we developed based on a cadaveric study. In 125 consecutive patients operated since 2002, we did not encounter any complication related to our tunneling method. Insufficient data exist to fully evaluate the advantages and disadvantages of each tunneling technique. It is of critical importance that authors detail their tunneling modus operandi and report the presence or absence of complications. This gathered data pool may help to formulate a definitive conclusions on the safest method for subcutaneous tunneling of extension wires in deep brain stimulation.
Systematic procedure for designing processes with multiple environmental objectives.
Kim, Ki-Joo; Smith, Raymond L
2005-04-01
Evaluation of multiple objectives is very important in designing environmentally benign processes. It requires a systematic procedure for solving multiobjective decision-making problems due to the complex nature of the problems, the need for complex assessments, and the complicated analysis of multidimensional results. In this paper, a novel systematic procedure is presented for designing processes with multiple environmental objectives. This procedure has four steps: initialization, screening, evaluation, and visualization. The first two steps are used for systematic problem formulation based on mass and energy estimation and order of magnitude analysis. In the third step, an efficient parallel multiobjective steady-state genetic algorithm is applied to design environmentally benign and economically viable processes and to provide more accurate and uniform Pareto optimal solutions. In the last step a new visualization technique for illustrating multiple objectives and their design parameters on the same diagram is developed. Through these integrated steps the decision-maker can easily determine design alternatives with respect to his or her preferences. Most importantly, this technique is independent of the number of objectives and design parameters. As a case study, acetic acid recovery from aqueous waste mixtures is investigated by minimizing eight potential environmental impacts and maximizing total profit. After applying the systematic procedure, the most preferred design alternatives and their design parameters are easily identified.
Sikka, Suresh C; Hellstrom, Wayne J G; Brock, Gerald; Morales, Antonio Martin
2013-01-01
In-office evaluation of erectile dysfunction by color duplex Doppler ultrasound (CDDU) may benefit the decision-making process in regard to choosing the most appropriate therapy. Unfortunately, there is no uniform standardization in performing CDDU resulting in high variability in data expression and interpretation when comparing results among various centers, especially when conducting multicenter trials. Establishing standard operating procedures (SOPs) is a major step that will help minimize such variability. This SOP describes CDDU procedure with focus on establishing uniformity and normative parameters. Measure intra-arterial diameter, peak systolic velocity, end-diastolic velocity, and resistive index for each cavernosal artery. After initial discussion with the patient about his history and International Index of Erectile Function evaluation describe procedural steps to the patient. Perform the CDDU in a relaxed state, scanning the entire penis (in B-mode image) using a 7.5- to 12-MHz linear array ultrasound probe. An intracorporal injection of a single or combination of vasoactive agents (e.g., prostaglandin E1, phentolamine, and papaverine) is then administered and CDDU performed at various time points, preferably with audiovisual sexual stimulation (AVSS). Monitor penile erection response (tumescence and rigidity) near peak blood flow. Self-stimulation or AVSS leaving the patient alone in room or redosing may be considered to decrease any anxiety and help achieve a maximum rigid erection. Considering the complexity and heterogeneity of CDDU evaluation, this communication will help in standardization and establish uniformity in such data interpretation. When indicated, invasive diagnostic testing involving (i) penile angiography and (ii) cavernosography/cavernosometry to establish veno-occlusive dysfunction may be recommended to facilitate further treatment options. © 2012 International Society for Sexual Medicine.
Single-step electrodeposition of CIS thin films with the complexing agent triethanolamine
NASA Astrophysics Data System (ADS)
Chiu, Yu-Shuen; Hsieh, Mu-Tao; Chang, Chih-Min; Chen, Chun-Shuo; Whang, Thou-Jen
2014-04-01
Some difficulties have long been encountered by single-step electrodeposition such as the optimization of electrolyte composition, deposition potentials, deposition time, and pH values. The approach of introducing ternary components into single-step electrodeposition is rather challenging especially due to the different values of the equilibrium potential for each constituent. Complexing agents play an important role in single-step electrodeposition of CuInSe2 (CIS), since the equilibrium potential of every constituent can be brought closer to each other when complexing agents are employed. In this work, single-step electrodeposition of CIS was enhanced by adding triethanolamine (TEA) into deposition bath, the CIS thin films were improved consequently in the form of polycrystalline cauliflower structures through the examination of SEM images and XRD patterns. The optimum composition of the solution for single-step electrodeposition of CIS is found to be 5 mM CuCl2, 22 mM InCl3, and 22 mM SeO2 at pH 1.5 with 0.1 M TEA. The structures, compositions, and morphologies of as-deposited and of annealed films were investigated.
Development of a standardized training course for laparoscopic procedures using Delphi methodology.
Bethlehem, Martijn S; Kramp, Kelvin H; van Det, Marc J; ten Cate Hoedemaker, Henk O; Veeger, Nicolaas J G M; Pierie, Jean Pierre E N
2014-01-01
Content, evaluation, and certification of laparoscopic skills and procedure training lack uniformity among different hospitals in The Netherlands. Within the process of developing a new regional laparoscopic training curriculum, a uniform and transferrable curriculum was constructed for a series of laparoscopic procedures. The aim of this study was to determine regional expert consensus regarding the key steps for laparoscopic appendectomy and cholecystectomy using Delphi methodology. Lists of suggested key steps for laparoscopic appendectomy and cholecystectomy were created using surgical textbooks, available guidelines, and local practice. A total of 22 experts, working for teaching hospitals throughout the region, were asked to rate the suggested key steps for both procedures on a Likert scale from 1-5. Consensus was reached with Crohnbach's α ≥ 0.90. Of the 22 experts, 21 completed and returned the survey (95%). Data analysis already showed consensus after the first round of Delphi on the key steps for laparoscopic appendectomy (Crohnbach's α = 0.92) and laparoscopic cholecystectomy (Crohnbach's α = 0.90). After the second round, 15 proposed key steps for laparoscopic appendectomy and 30 proposed key steps for laparoscopic cholecystectomy were rated as important (≥4 by at least 80% of the expert panel). These key steps were used for the further development of the training curriculum. By using the Delphi methodology, regional consensus was reached on the key steps for laparoscopic appendectomy and cholecystectomy. These key steps are going to be used for standardized training and evaluation purposes in a new regional laparoscopic curriculum. Copyright © 2014 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.
Coherent control with optical pulses for deterministic spin-photon entanglement
NASA Astrophysics Data System (ADS)
Truex, Katherine; Webster, L. A.; Duan, L.-M.; Sham, L. J.; Steel, D. G.
2013-11-01
We present a procedure for the optical coherent control of quantum bits within a quantum dot spin-exciton system, as a preliminary step to implementing a proposal by Yao, Liu, and Sham [Phys. Rev. Lett.PRLTAO0031-900710.1103/PhysRevLett.95.030504 95, 030504 (2005)] for deterministic spin-photon entanglement. The experiment proposed here utilizes a series of picosecond optical pulses from a single laser to coherently control a single self-assembled quantum dot in a magnetic field, creating the precursor state in 25 ps with a predicted fidelity of 0.991. If allowed to decay in an appropriate cavity, the ideal precursor superposition state would create maximum spin-photon entanglement. Numerical simulations using values typical of InAs quantum dots give a predicted entropy of entanglement of 0.929, largely limited by radiative decay and electron spin flips.
A hollow definitive obturator fabrication technique for management of partial maxillectomy.
Patil, Pravinkumar Gajanan; Patil, Smita Pravinkumar
2012-11-01
Maxillary obturator prosthesis is the most frequent treatment option for management of partial or total maxillectomy. Heavy weight of the obturators is often a dislocating factor. Hollowing the prosthesis to reduce its weight is the well established fact. The alternate technique to hollow-out the prosthesis has been described in this article which is a variation of previously described processing techniques. A pre-shaped wax-bolus was incorporated inside the flasks during packing of the heat-polymerized acrylic resin to automatically create the hollow space. The processing technique described is a single step flasking procedure to construct a closed-hollow-obturator prosthesis as a single unit. To best understand the technique, this article describes management of a patient who had undergone partial maxillectomy secondary to squamous cell carcinoma rehabilitated with a hollow-obturator prosthesis.
A hollow definitive obturator fabrication technique for management of partial maxillectomy
Patil, Smita Pravinkumar
2012-01-01
Maxillary obturator prosthesis is the most frequent treatment option for management of partial or total maxillectomy. Heavy weight of the obturators is often a dislocating factor. Hollowing the prosthesis to reduce its weight is the well established fact. The alternate technique to hollow-out the prosthesis has been described in this article which is a variation of previously described processing techniques. A pre-shaped wax-bolus was incorporated inside the flasks during packing of the heat-polymerized acrylic resin to automatically create the hollow space. The processing technique described is a single step flasking procedure to construct a closed-hollow-obturator prosthesis as a single unit. To best understand the technique, this article describes management of a patient who had undergone partial maxillectomy secondary to squamous cell carcinoma rehabilitated with a hollow-obturator prosthesis. PMID:23236579
A posteriori model validation for the temporal order of directed functional connectivity maps.
Beltz, Adriene M; Molenaar, Peter C M
2015-01-01
A posteriori model validation for the temporal order of neural directed functional connectivity maps is rare. This is striking because models that require sequential independence among residuals are regularly implemented. The aim of the current study was (a) to apply to directed functional connectivity maps of functional magnetic resonance imaging data an a posteriori model validation procedure (i.e., white noise tests of one-step-ahead prediction errors combined with decision criteria for revising the maps based upon Lagrange Multiplier tests), and (b) to demonstrate how the procedure applies to single-subject simulated, single-subject task-related, and multi-subject resting state data. Directed functional connectivity was determined by the unified structural equation model family of approaches in order to map contemporaneous and first order lagged connections among brain regions at the group- and individual-levels while incorporating external input, then white noise tests were run. Findings revealed that the validation procedure successfully detected unmodeled sequential dependencies among residuals and recovered higher order (greater than one) simulated connections, and that the procedure can accommodate task-related input. Findings also revealed that lags greater than one were present in resting state data: With a group-level network that contained only contemporaneous and first order connections, 44% of subjects required second order, individual-level connections in order to obtain maps with white noise residuals. Results have broad methodological relevance (e.g., temporal validation is necessary after directed functional connectivity analyses because the presence of unmodeled higher order sequential dependencies may bias parameter estimates) and substantive implications (e.g., higher order lags may be common in resting state data).
Operational procedures for ground station operation: ATS-3 Hawaii-Ames satellite link experiment
NASA Technical Reports Server (NTRS)
Nishioka, K.; Gross, E. H.
1979-01-01
Hardware description and operational procedures for the ATS-3 Hawaii-Ames satellite computer link are presented in basic step-by-step instructions. Transmit and receive channels and frequencies are given. Details such as switch settings for activating the station to the sequence of turning switches on are provided. Methods and procedures for troubleshooting common problems encountered with communication stations are also provided.
Feature-based US to CT registration of the aortic root
NASA Astrophysics Data System (ADS)
Lang, Pencilla; Chen, Elvis C. S.; Guiraudon, Gerard M.; Jones, Doug L.; Bainbridge, Daniel; Chu, Michael W.; Drangova, Maria; Hata, Noby; Jain, Ameet; Peters, Terry M.
2011-03-01
A feature-based registration was developed to align biplane and tracked ultrasound images of the aortic root with a preoperative CT volume. In transcatheter aortic valve replacement, a prosthetic valve is inserted into the aortic annulus via a catheter. Poor anatomical visualization of the aortic root region can result in incorrect positioning, leading to significant morbidity and mortality. Registration of pre-operative CT to transesophageal ultrasound and fluoroscopy images is a major step towards providing augmented image guidance for this procedure. The proposed registration approach uses an iterative closest point algorithm to register a surface mesh generated from CT to 3D US points reconstructed from a single biplane US acquisition, or multiple tracked US images. The use of a single simultaneous acquisition biplane image eliminates reconstruction error introduced by cardiac gating and TEE probe tracking, creating potential for real-time intra-operative registration. A simple initialization procedure is used to minimize changes to operating room workflow. The algorithm is tested on images acquired from excised porcine hearts. Results demonstrate a clinically acceptable accuracy of 2.6mm and 5mm for tracked US to CT and biplane US to CT registration respectively.
... No single step can protect you from every single type of STI. Can women who have sex with women get PID? Yes. ... No single step can protect you from every single type of STI. Can women who have sex with women get PID? Yes. ...
Single crystal growth from separated educts and its application to lithium transition-metal oxides
Freund, F.; Williams, S. C.; Johnson, R. D.; Coldea, R.; Gegenwart, P.; Jesche, A.
2016-01-01
Thorough mixing of the starting materials is the first step of a crystal growth procedure. This holds true for almost any standard technique, whereas the intentional separation of educts is considered to be restricted to a very limited number of cases. Here we show that single crystals of α-Li2IrO3 can be grown from separated educts in an open crucible in air. Elemental lithium and iridium are oxidized and transported over a distance of typically one centimeter. In contrast to classical vapor transport, the process is essentially isothermal and a temperature gradient of minor importance. Single crystals grow from an exposed condensation point placed in between the educts. The method has also been applied to the growth of Li2RuO3, Li2PtO3 and β-Li2IrO3. A successful use of this simple and low cost technique for various other materials is anticipated. PMID:27748402
Universal single level implicit algorithm for gasdynamics
NASA Technical Reports Server (NTRS)
Lombard, C. K.; Venkatapthy, E.
1984-01-01
A single level effectively explicit implicit algorithm for gasdynamics is presented. The method meets all the requirements for unconditionally stable global iteration over flows with mixed supersonic and supersonic zones including blunt body flow and boundary layer flows with strong interaction and streamwise separation. For hyperbolic (supersonic flow) regions the method is automatically equivalent to contemporary space marching methods. For elliptic (subsonic flow) regions, rapid convergence is facilitated by alternating direction solution sweeps which bring both sets of eigenvectors and the influence of both boundaries of a coordinate line equally into play. Point by point updating of the data with local iteration on the solution procedure at each spatial step as the sweeps progress not only renders the method single level in storage but, also, improves nonlinear accuracy to accelerate convergence by an order of magnitude over related two level linearized implicit methods. The method derives robust stability from the combination of an eigenvector split upwind difference method (CSCM) with diagonally dominant ADI(DDADI) approximate factorization and computed characteristic boundary approximations.
Robson, Scott A; Takeuchi, Koh; Boeszoermenyi, Andras; Coote, Paul W; Dubey, Abhinav; Hyberts, Sven; Wagner, Gerhard; Arthanari, Haribabu
2018-01-24
Backbone resonance assignment is a critical first step in the investigation of proteins by NMR. This is traditionally achieved with a standard set of experiments, most of which are not optimal for large proteins. Of these, HNCA is the most sensitive experiment that provides sequential correlations. However, this experiment suffers from chemical shift degeneracy problems during the assignment procedure. We present a strategy that increases the effective resolution of HNCA and enables near-complete resonance assignment using this single HNCA experiment. We utilize a combination of 2- 13 C and 3- 13 C pyruvate as the carbon source for isotope labeling, which suppresses the one bond ( 1 J αβ ) coupling providing enhanced resolution for the Cα resonance and amino acid-specific peak shapes that arise from the residual coupling. Using this approach, we can obtain near-complete (>85%) backbone resonance assignment of a 42 kDa protein using a single HNCA experiment.
Matsunaga, Taichi; Yamashita, Jun K
2014-02-07
Specific gene knockout and rescue experiments are powerful tools in developmental and stem cell biology. Nevertheless, the experiments require multiple steps of molecular manipulation for gene knockout and subsequent rescue procedures. Here we report an efficient and single step strategy to generate gene knockout-rescue system in pluripotent stem cells by promoter insertion with CRISPR/Cas9 genome editing technology. We inserted a tetracycline-regulated inducible gene promoter (tet-OFF/TRE-CMV) upstream of the endogenous promoter region of vascular endothelial growth factor receptor 2 (VEGFR2/Flk1) gene, an essential gene for endothelial cell (EC) differentiation, in mouse embryonic stem cells (ESCs) with homologous recombination. Both homo- and hetero-inserted clones were efficiently obtained through a simple selection with a drug-resistant gene. The insertion of TRE-CMV promoter disrupted endogenous Flk1 expression, resulting in null mutation in homo-inserted clones. When the inserted TRE-CMV promoter was activated with doxycycline (Dox) depletion, Flk1 expression was sufficiently recovered from the downstream genomic Flk1 gene. Whereas EC differentiation was almost completely perturbed in homo-inserted clones, Flk1 rescue with TRE-CMV promoter activation restored EC appearance, indicating that phenotypic changes in EC differentiation can be successfully reproduced with this knockout-rescue system. Thus, this promoter insertion strategy with CRISPR/Cas9 would be a novel attractive method for knockout-rescue experiments. Copyright © 2014 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Shen, Yannan; Istock, André; Zaman, Anik; Woidt, Carsten; Hillmer, Hartmut
2018-05-01
Miniaturization of optical spectrometers can be achieved by Fabry-Pérot (FP) filter arrays. Each FP filter consists of two parallel highly reflecting mirrors and a resonance cavity in between. Originating from different individual cavity heights, each filter transmits a narrow spectral band (transmission line) with different wavelengths. Considering the fabrication efficiency, plasma enhanced chemical vapor deposition (PECVD) technology is applied to implement the high-optical-quality distributed Bragg reflectors (DBRs), while substrate conformal imprint lithography (one type of nanoimprint technology) is utilized to achieve the multiple cavities in just a single step. The FP filter array fabricated by nanoimprint combined with corresponding detector array builds a so-called "nanospectrometer". However, the silicon nitride and silicon dioxide stacks deposited by PECVD result in a limited stopband width of DBR (i.e., < 100 nm), which then limits the sensing range of filter arrays. However, an extension of the spectral range of filter arrays is desired and the topic of this investigation. In this work, multiple DBRs with different central wavelengths (λ c) are structured, deposited, and combined on a single substrate to enlarge the entire stopband. Cavity arrays are successfully aligned and imprinted over such terrace like surface in a single step. With this method, small chip size of filter arrays can be preserved, and the fabrication procedure of multiple resonance cavities is kept efficient as well. The detecting range of filter arrays is increased from roughly 50 nm with single DBR to 163 nm with three different DBRs.
Hsieh, Hong-Po; Ko, Fan-Hua; Sung, Kung-Bin
2018-04-20
An iterative curve fitting method has been applied in both simulation [J. Biomed. Opt.17, 107003 (2012)JBOPFO1083-366810.1117/1.JBO.17.10.107003] and phantom [J. Biomed. Opt.19, 077002 (2014)JBOPFO1083-366810.1117/1.JBO.19.7.077002] studies to accurately extract optical properties and the top layer thickness of a two-layered superficial tissue model from diffuse reflectance spectroscopy (DRS) data. This paper describes a hybrid two-step parameter estimation procedure to address two main issues of the previous method, including (1) high computational intensity and (2) converging to local minima. The parameter estimation procedure contained a novel initial estimation step to obtain an initial guess, which was used by a subsequent iterative fitting step to optimize the parameter estimation. A lookup table was used in both steps to quickly obtain reflectance spectra and reduce computational intensity. On simulated DRS data, the proposed parameter estimation procedure achieved high estimation accuracy and a 95% reduction of computational time compared to previous studies. Furthermore, the proposed initial estimation step led to better convergence of the following fitting step. Strategies used in the proposed procedure could benefit both the modeling and experimental data processing of not only DRS but also related approaches such as near-infrared spectroscopy.
NASA Technical Reports Server (NTRS)
Peters, B. C., Jr.; Walker, H. F.
1978-01-01
This paper addresses the problem of obtaining numerically maximum-likelihood estimates of the parameters for a mixture of normal distributions. In recent literature, a certain successive-approximations procedure, based on the likelihood equations, was shown empirically to be effective in numerically approximating such maximum-likelihood estimates; however, the reliability of this procedure was not established theoretically. Here, we introduce a general iterative procedure, of the generalized steepest-ascent (deflected-gradient) type, which is just the procedure known in the literature when the step-size is taken to be 1. We show that, with probability 1 as the sample size grows large, this procedure converges locally to the strongly consistent maximum-likelihood estimate whenever the step-size lies between 0 and 2. We also show that the step-size which yields optimal local convergence rates for large samples is determined in a sense by the 'separation' of the component normal densities and is bounded below by a number between 1 and 2.
NASA Technical Reports Server (NTRS)
Peters, B. C., Jr.; Walker, H. F.
1976-01-01
The problem of obtaining numerically maximum likelihood estimates of the parameters for a mixture of normal distributions is addressed. In recent literature, a certain successive approximations procedure, based on the likelihood equations, is shown empirically to be effective in numerically approximating such maximum-likelihood estimates; however, the reliability of this procedure was not established theoretically. Here, a general iterative procedure is introduced, of the generalized steepest-ascent (deflected-gradient) type, which is just the procedure known in the literature when the step-size is taken to be 1. With probability 1 as the sample size grows large, it is shown that this procedure converges locally to the strongly consistent maximum-likelihood estimate whenever the step-size lies between 0 and 2. The step-size which yields optimal local convergence rates for large samples is determined in a sense by the separation of the component normal densities and is bounded below by a number between 1 and 2.
[Replacement of dogs as research animals for the approval testing of plant protection products].
Box, Rainer J
2006-01-01
The replacement of animal testing using dogs for the registration of plant protection products requires a long-term step-by-step procedure. The first goal should be to achieve international agreement on using only one single study in dogs. This would result in a significant short-term reduction of the use of dogs for this purpose. The competent working groups both in the EU and the United States EPA have declared this to be their intended aim. In this context, the 90-day study is to be the preferred study from the scientific as well as the animal welfare points of view. It is proposed to set up an international expert task force within the next 12 months, which should seek to initiate a process of international harmonization of the testing requirements following the example of the International Conference of Harmonization of Technical Requirements for Medical Products, ICH. The goal should be to achieve international agreement on only one single study with dogs within the next 2 to 3 years. In addition, other valid scientific procedures, with which the use of dogs for testing can be reduced, should be critically assessed. A complete replacement of the use of dogs for plant protection product testing is suggested to take place at a later stage. This may be achieved by either deriving safety threshold values by applying a safety factor to chronic NOAEL values obtained in studies using rats for those groups of substances, for which there is evidence that the dog is the more sensitive species, or by combining the chronic rat study with other animal tests stipulated for the registration of pesticides.
Laparoendoscopic Single-Site Sentinel Lymph Node Detection in Endometrial Cancer.
Demirayak, Gökhan; Comba, Cihan; Özdemir, İsa Aykut
2017-11-13
To demonstrate the feasibility of sentinel lymph node (SLN) biopsy using a laparoendoscopic single-site (LESS) approach in endometrial cancer (EC). A step-by-step video demonstration of the surgical procedure (Canadian Task Force Classification III). The satisfaction of patients who undergo LESS hysterectomy is greater than that reported by patients who undergo multiport laparoscopic hysterectomy, owing to better cosmesis and reduced postoperative analgesic requirements [1]. SLN biopsy is associated with significantly lower estimated blood loss, shorter operation time, and less morbidity compared with systematic lymphadenectomy [2]. LESS surgery can be more feasible and safer with the use of SLN biopsy compared with complete lymphadenectomy in patients with early-stage EC. This 69-year-old woman with grade 2 endometrioid EC underwent SLN mapping followed by LESS SLN biopsy, total hysterectomy, and bilateral salpingo-oophorectomy. Before the umbilical incision was made, 1.25 mg/mL of indocyanine green was injected into the cervical stroma at the 3 o'clock and 9 o'clock positions to both deep and superficial levels. A 10-mm 30° standard-length optical camera for near-infrared fluorescence imaging was used. The total operative time was 75 minutes, and the estimated blood loss was 20 mL. SLNs were detected bilaterally between proximal parts of the external iliac arteries and veins. After SLN resection, total hysterectomy and bilateral salpingo-oophorectomy were performed. No postoperative complications occurred. The patient was discharged at 30 hours after surgery. In the final pathology, stage 1A G2 EC was detected. LESS SLN biopsy and TLH-BSO is a feasible procedure and sentinel lymph node concept may increase the use of LESS in EC. Copyright © 2017 American Association of Gynecologic Laparoscopists. Published by Elsevier Inc. All rights reserved.
A successful backward step correlates with hip flexion moment of supporting limb in elderly people.
Takeuchi, Yahiko
2018-01-01
The objective of this study was to determine the positional relationship between the center of mass (COM) and the center of pressure (COP) at the time of step landing, and to examine their relationship with the joint moments exerted by the supporting limb, with regard to factors of the successful backward step response. The study population comprised 8 community-dwelling elderly people that were observed to take successive multi steps after the landing of a backward stepping. Using a motion capture system and force plate, we measured the COM, COP and COM-COP deviation distance on landing during backward stepping. In addition, we measured the moment of the supporting limb joint during backward stepping. The multi-step data were compared with data from instances when only one step was taken (single-step). Variables that differed significantly between the single- and multi-step data were used as objective variables and the joint moments of the supporting limb were used as explanatory variables in single regression analyses. The COM-COP deviation in the anteroposterior was significantly larger in the single-step. A regression analysis with COM-COP deviation as the objective variable obtained a significant regression equation in the hip flexion moment (R2 = 0.74). The hip flexion moment of supporting limb was shown to be a significant explanatory variable in both the PS and SS phases for the relationship with COM-COP distance. This study found that to create an appropriate backward step response after an external disturbance (i.e. the ability to stop after 1 step), posterior braking of the COM by a hip flexion moment are important during the single-limbed standing phase.
Mapping sea ice leads with a coupled numeric/symbolic system
NASA Technical Reports Server (NTRS)
Key, J.; Schweiger, A. J.; Maslanik, J. A.
1990-01-01
A method is presented which facilitates the detection and delineation of leads with single-channel Landsat data by coupling numeric and symbolic procedures. The procedure consists of three steps: (1) using the dynamic threshold method, an image is mapped to a lead/no lead binary image; (2) the likelihood of fragments to be real leads is examined with a set of numeric rules; and (3) pairs of objects are examined geometrically and merged where possible. The processing ends when all fragments are merged and statistical characteristics are determined, and a map of valid lead objects are left which summarizes useful physical in the lead complexes. Direct implementation of domain knowledge and rapid prototyping are two benefits of the rule-based system. The approach is found to be more successfully applied to mid- and high-level processing, and the system can retrieve statistics about sea-ice leads as well as detect the leads.
Sklerov, J H; Kalasinsky, K S; Ehorn, C A
1999-10-01
A confirmatory method for the detection and quantitation of lysergic acid diethylamide (LSD) is presented. The method employs gas chromatography-tandem mass spectrometry (GC-MS-MS) using an internal ionization ion trap detector for sensitive MS-MS-in-time measurements of LSD extracted from urine. Following a single-step solid-phase extraction of 5 mL of urine, underivatized LSD can be measured with limits of quantitation and detection of 80 and 20 pg/mL, respectively. Temperature-programmed on-column injections of urine extracts were linear over the concentration range 20-2000 pg/mL (r2 = 0.999). Intraday and interday coefficients of variation were < 6% and < 13%, respectively. This procedure has been applied to quality-control specimens and LSD-positive samples in this laboratory. Comparisons with alternate GC-MS methods and extraction procedures are discussed.
ebb® Complete Tamponade System: effective hemostasis for postpartum hemorrhage
McQuivey, Ross W; Block, Jon E; Massaro, Robert A
2018-01-01
As a leading cause of maternal death, postpartum hemorrhage (PPH) remains a worldwide obstetrical problem. However, in most cases, mortality and morbidity can be averted if efforts are immediately undertaken to achieve hemostasis. Uterine balloon tamponade has been shown to provide effective control of PPH and avoid more invasive surgical procedures and even the emergency peripartum hysterectomy. Recent clinical recommendation suggests that balloon tamponade should be considered earlier in the treatment cascade in conjunction with uterotonic agents to ensure hemostasis in the most timely fashion and maximize clinical outcomes. This paper profiles the ebb® Complete Tamponade System, a unique dual-balloon single-use device that was developed specifically for hemostatic management of PPH. The ebb system combines a uterine conforming balloon that can be rapidly deployed with a vaginal balloon that eliminates the need for vaginal packing. The description, indications for use, procedural steps, and clinical characterization of this device are presented. PMID:29535559
Novel posterior fixation keratoprosthesis
NASA Astrophysics Data System (ADS)
Lacombe, Emmanuel
1992-08-01
The keratoprosthesis is the last solution for corneally blind patients that cannot benefit from corneal transplants. Keratoprostheses that have been designed to be affixed anteriorly usually necessitate multi-step surgical procedures and are continuously subjected to the extrusion forces generated by the positive intraocular pressure; therefore, clinical results in patients prove inconsistent. We proposed a novel keratoprosthesis concept that utilizes posterior corneal fixation which `a priori' minimizes the risk of aqueous leakage and expulsion. This prosthesis is implanted in a single procedure thereby reducing the number of surgical complications normally associated with anterior fixation devices. In addition, its novel design makes this keratoprosthesis implantable in phakic eyes. With an average follow-up of 13 months (range 3 to 25 months), our results on 21 cases are encouraging. Half of the keratoprostheses were implanted in severe burn cases, with the remainder in cases of pseudo- pemphigus. Good visual results and cosmetic appearance were obtained in 14 of 21 eyes.
A variationally coupled FE-BE method for elasticity and fracture mechanics
NASA Technical Reports Server (NTRS)
Lu, Y. Y.; Belytschko, T.; Liu, W. K.
1991-01-01
A new method for coupling finite element and boundary element subdomains in elasticity and fracture mechanics problems is described. The essential feature of this new method is that a single variational statement is obtained for the entire domain, and in this process the terms associated with tractions on the interfaces between the subdomains are eliminated. This provides the additional advantage that the ambiguities associated with the matching of discontinuous tractions are circumvented. The method leads to a direct procedure for obtaining the discrete equations for the coupled problem without any intermediate steps. In order to evaluate this method and compare it with previous methods, a patch test for coupled procedures has been devised. Evaluation of this variationally coupled method and other methods, such as stiffness coupling and constraint traction matching coupling, shows that this method is substantially superior. Solutions for a series of fracture mechanics problems are also reported to illustrate the effectiveness of this method.
ebb® Complete Tamponade System: effective hemostasis for postpartum hemorrhage.
McQuivey, Ross W; Block, Jon E; Massaro, Robert A
2018-01-01
As a leading cause of maternal death, postpartum hemorrhage (PPH) remains a worldwide obstetrical problem. However, in most cases, mortality and morbidity can be averted if efforts are immediately undertaken to achieve hemostasis. Uterine balloon tamponade has been shown to provide effective control of PPH and avoid more invasive surgical procedures and even the emergency peripartum hysterectomy. Recent clinical recommendation suggests that balloon tamponade should be considered earlier in the treatment cascade in conjunction with uterotonic agents to ensure hemostasis in the most timely fashion and maximize clinical outcomes. This paper profiles the ebb ® Complete Tamponade System, a unique dual-balloon single-use device that was developed specifically for hemostatic management of PPH. The ebb system combines a uterine conforming balloon that can be rapidly deployed with a vaginal balloon that eliminates the need for vaginal packing. The description, indications for use, procedural steps, and clinical characterization of this device are presented.
de Mel, Achala; Ramesh, Bala; Scurr, David J; Alexander, Morgan R; Hamilton, George; Birchall, Martin; Seifalian, Alexander M
2014-03-01
Replacement of irreversibly damaged organs due to chronic disease, with suitable tissue engineered implants is now a familiar area of interest to clinicians and multidisciplinary scientists. Ideal tissue engineering approaches require scaffolds to be tailor made to mimic physiological environments of interest with specific surface topographical and biological properties for optimal cell-material interactions. This study demonstrates a single-step procedure for inducing biomimicry in a novel nanocomposite base material scaffold, to re-create the extracellular matrix, which is required for stem cell integration and differentiation to mature cells. Fumed silica nanoparticle mediated procedure of scaffold functionalization, can be potentially adapted with multiple bioactive molecules to induce cellular biomimicry, in the development human organs. The proposed nanocomposite materials already in patients for number of implants, including world first synthetic trachea, tear ducts and vascular bypass graft. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Kopp-Schneider, Annette; Prieto, Pilar; Kinsner-Ovaskainen, Agnieszka; Stanzel, Sven
2013-06-01
In the framework of toxicology, a testing strategy can be viewed as a series of steps which are taken to come to a final prediction about a characteristic of a compound under study. The testing strategy is performed as a single-step procedure, usually called a test battery, using simultaneously all information collected on different endpoints, or as tiered approach in which a decision tree is followed. Design of a testing strategy involves statistical considerations, such as the development of a statistical prediction model. During the EU FP6 ACuteTox project, several prediction models were proposed on the basis of statistical classification algorithms which we illustrate here. The final choice of testing strategies was not based on statistical considerations alone. However, without thorough statistical evaluations a testing strategy cannot be identified. We present here a number of observations made from the statistical viewpoint which relate to the development of testing strategies. The points we make were derived from problems we had to deal with during the evaluation of this large research project. A central issue during the development of a prediction model is the danger of overfitting. Procedures are presented to deal with this challenge. Copyright © 2012 Elsevier Ltd. All rights reserved.
Gurram, Venkateshwarlu; Pottabathini, Narender; Garlapati, Ramesh; Chaudhary, Avinash B; Patro, Balaram; Lakshman, Mahesh K
2012-08-01
Reaction conditions for the CC cross-coupling of O(6)-alkyl-2-bromo- and 2-chloroinosine derivatives with aryl-, hetaryl-, and alkylboronic acids were studied. Optimization experiments with silyl-protected 2-bromo-O(6)-methylinosine led to the identification of [PdCl(2)(dcpf)]/K(3)PO(4) in 1,4-dioxane as the best conditions for these reactions (dcpf=1,1'-bis(dicyclohexylphosphino)ferrocene). Attempted O(6)-demethylation, as well as the replacement of the C-6 methoxy group by amines, was unsuccessful, which led to the consideration of Pd-cleavable groups such that C-C cross-coupling and O(6)-deprotection could be accomplished in a single step. Thus, inosine 2-chloro-O(6)-allylinosine was chosen as the substrate and, after re-evaluation of the cross-coupling conditions with 2-chloro-O(6)-methylinosine as a model substrate, one-step C-C cross-coupling/deprotection reactions were performed with the O(6)-allyl analogue. These reactions are the first such examples of a one-pot procedure for the modification and deprotection of purine nucleosides under C-C cross-coupling conditions. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
NASA Astrophysics Data System (ADS)
Yao, Jianzhuang; Yuan, Yaxia; Zheng, Fang; Zhan, Chang-Guo
2016-02-01
Extensive computational modeling and simulations have been carried out, in the present study, to uncover the fundamental reaction pathway for butyrylcholinesterase (BChE)-catalyzed hydrolysis of ghrelin, demonstrating that the acylation process of BChE-catalyzed hydrolysis of ghrelin follows an unprecedented single-step reaction pathway and the single-step acylation process is rate-determining. The free energy barrier (18.8 kcal/mol) calculated for the rate-determining step is reasonably close to the experimentally-derived free energy barrier (~19.4 kcal/mol), suggesting that the obtained mechanistic insights are reasonable. The single-step reaction pathway for the acylation is remarkably different from the well-known two-step acylation reaction pathway for numerous ester hydrolysis reactions catalyzed by a serine esterase. This is the first time demonstrating that a single-step reaction pathway is possible for an ester hydrolysis reaction catalyzed by a serine esterase and, therefore, one no longer can simply assume that the acylation process must follow the well-known two-step reaction pathway.
Kosterhon, Michael; Gutenberg, Angelika; Kantelhardt, Sven R; Conrad, Jens; Nimer Amr, Amr; Gawehn, Joachim; Giese, Alf
2017-08-01
A feasibility study. To develop a method based on the DICOM standard which transfers complex 3-dimensional (3D) trajectories and objects from external planning software to any navigation system for planning and intraoperative guidance of complex spinal procedures. There have been many reports about navigation systems with embedded planning solutions but only few on how to transfer planning data generated in external software. Patients computerized tomography and/or magnetic resonance volume data sets of the affected spinal segments were imported to Amira software, reconstructed to 3D images and fused with magnetic resonance data for soft-tissue visualization, resulting in a virtual patient model. Objects needed for surgical plans or surgical procedures such as trajectories, implants or surgical instruments were either digitally constructed or computerized tomography scanned and virtually positioned within the 3D model as required. As crucial step of this method these objects were fused with the patient's original diagnostic image data, resulting in a single DICOM sequence, containing all preplanned information necessary for the operation. By this step it was possible to import complex surgical plans into any navigation system. We applied this method not only to intraoperatively adjustable implants and objects under experimental settings, but also planned and successfully performed surgical procedures, such as the percutaneous lateral approach to the lumbar spine following preplanned trajectories and a thoracic tumor resection including intervertebral body replacement using an optical navigation system. To demonstrate the versatility and compatibility of the method with an entirely different navigation system, virtually preplanned lumbar transpedicular screw placement was performed with a robotic guidance system. The presented method not only allows virtual planning of complex surgical procedures, but to export objects and surgical plans to any navigation or guidance system able to read DICOM data sets, expanding the possibilities of embedded planning software.
Palmirotta, Raffaele; Lovero, Domenica; Silvestris, Erica; Felici, Claudia; Quaresmini, Davide; Cafforio, Paola; Silvestris, Franco
2017-01-01
Isolation and genotyping of circulating tumor cells (CTCs) is gaining an increasing interest by clinical researchers in oncology not only for investigative purposes, but also for concrete application in clinical practice in terms of diagnosis, prognosis and decision treatment with targeted therapies. For the mutational analysis of single CTCs, the most advanced biotechnology methodology currently available includes the combination of whole genome amplification (WGA) followed by next-generation sequencing (NGS). However, the sequence of these molecular techniques is time-consuming and may also favor operator-dependent errors, related to the procedures themselves that, as in the case of the WGA technique, might affect downstream molecular analyses. A preliminary approach of molecular analysis by NGS on a model of CTCs without previous WGA procedural step was performed. We set-up an artificial sample obtained by spiking the SK-MEL-28 melanoma cell line in normal donor peripheral whole blood. Melanoma cells were first enriched using an AutoMACS® (Miltenyi) cell separator and then isolated as single and pooled CTCs by DEPArray™ System (Silicon Biosystems). NGS analysis, using the Ion AmpliSeq™ Cancer Hotspot Panel v2 (Life Technologies) with the Ion Torrent PGM™ system (Life Technologies), was performed on the SK-MEL-28 cell pellet, a single CTC previously processed with WGA and on 1, 2, 4 and 8 recovered CTCs without WGA pre-amplification. NGS directly carried out on CTCs without WGA showed the same mutations identified in SK-MEL-28 cell line pellet, with a considerable efficiency and avoiding the errors induced by the WGA procedure. We identified a cost-effective, time-saving and reliable methodological approach that could improve the analytical accuracy of the liquid biopsy and appears promising in studying CTCs from cancer patients for both research and clinical purposes. Copyright© 2017, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.
Design procedures for fiber composite structural components - Rods, beams, and beam columns
NASA Technical Reports Server (NTRS)
Chamis, C. C.
1984-01-01
Step by step procedures are described which are used to design structural components (rods, columns, and beam columns) subjected to steady state mechanical loads and hydrothermal environments. Illustrative examples are presented for structural components designed for static tensile and compressive loads, and fatigue as well as for moisture and temperature effects. Each example is set up as a sample design illustrating the detailed steps that are used to design similar components.
Design procedures for fiber composite structural components: Rods, columns and beam columns
NASA Technical Reports Server (NTRS)
Chamis, C. C.
1983-01-01
Step by step procedures are described which are used to design structural components (rods, columns, and beam columns) subjected to steady state mechanical loads and hydrothermal environments. Illustrative examples are presented for structural components designed for static tensile and compressive loads, and fatigue as well as for moisture and temperature effects. Each example is set up as a sample design illustrating the detailed steps that are used to design similar components.
Project W-314 specific test and evaluation plan for transfer line SN-633 (241-AX-B to 241-AY-02A)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hays, W.H.
1998-03-20
The purpose of this Specific Test and Evaluation Plan (STEP) is to provide a detailed written plan for the systematic testing of modifications made by the addition of the SN-633 transfer line by the W-314 Project. The STEP develops the outline for test procedures that verify the system`s performance to the established Project design criteria. The STEP is a lower tier document based on the W-314 Test and Evaluation Plan (TEP). This STEP encompasses all testing activities required to demonstrate compliance to the project design criteria as it relates to the addition of transfer line SN-633. The Project Design Specificationsmore » (PDS) identify the specific testing activities required for the Project. Testing includes Validations and Verifications (e.g., Commercial Grade Item Dedication activities), Factory Acceptance Tests (FATs), installation tests and inspections, Construction Acceptance Tests (CATs), Acceptance Test Procedures (ATPs), Pre-Operational Test Procedures (POTPs), and Operational Test Procedures (OTPs). It should be noted that POTPs are not required for testing of the transfer line addition. The STEP will be utilized in conjunction with the TEP for verification and validation.« less
Aseptic laboratory techniques: plating methods.
Sanders, Erin R
2012-05-11
Microorganisms are present on all inanimate surfaces creating ubiquitous sources of possible contamination in the laboratory. Experimental success relies on the ability of a scientist to sterilize work surfaces and equipment as well as prevent contact of sterile instruments and solutions with non-sterile surfaces. Here we present the steps for several plating methods routinely used in the laboratory to isolate, propagate, or enumerate microorganisms such as bacteria and phage. All five methods incorporate aseptic technique, or procedures that maintain the sterility of experimental materials. Procedures described include (1) streak-plating bacterial cultures to isolate single colonies, (2) pour-plating and (3) spread-plating to enumerate viable bacterial colonies, (4) soft agar overlays to isolate phage and enumerate plaques, and (5) replica-plating to transfer cells from one plate to another in an identical spatial pattern. These procedures can be performed at the laboratory bench, provided they involve non-pathogenic strains of microorganisms (Biosafety Level 1, BSL-1). If working with BSL-2 organisms, then these manipulations must take place in a biosafety cabinet. Consult the most current edition of the Biosafety in Microbiological and Biomedical Laboratories (BMBL) as well as Material Safety Data Sheets (MSDS) for Infectious Substances to determine the biohazard classification as well as the safety precautions and containment facilities required for the microorganism in question. Bacterial strains and phage stocks can be obtained from research investigators, companies, and collections maintained by particular organizations such as the American Type Culture Collection (ATCC). It is recommended that non-pathogenic strains be used when learning the various plating methods. By following the procedures described in this protocol, students should be able to: Perform plating procedures without contaminating media. Isolate single bacterial colonies by the streak-plating method. Use pour-plating and spread-plating methods to determine the concentration of bacteria. Perform soft agar overlays when working with phage. Transfer bacterial cells from one plate to another using the replica-plating procedure. Given an experimental task, select the appropriate plating method.
Cervera, R P; Garcia-Ximénez, F
2003-10-01
The purpose of this study was to test the effectiveness of one two-step (A) and two one-step (B1 and B2) vitrification procedures on denuded expanded or hatching rabbit blastocysts held in standard sealed plastic straws as a possible model for human blastocysts. The effect of blastocyst size was also studied on the basis of three size categories (I: diameter <200 micro m; II: diameter 200-299 micro m; III: diameter >/==" BORDER="0">300 micro m). Rabbit expanded or hatching blastocysts were vitrified at day 4 or 5. Before vitrification, the zona pellucida was removed using acidic phosphate buffered saline. For the two-step procedure, prior to vitrification, blastocysts were pre- equilibrated in a solution containing 10% dimethyl sulphoxide (DMSO) and 10% ethylene glycol (EG) for 1 min. Different final vitrification solutions were compared: 20% DMSO and 20% EG with (A and B1) or without (B2) 0.5 mol/l sucrose. Of 198 vitrified blastocysts, 181 (91%) survived, regardless of the vitrification procedure applied. Vitrification procedure A showed significantly higher re-expansion (88%), attachment (86%) and trophectoderm outgrowth (80%) rates than the two one-step vitrification procedures, B1 and B2 (46 and 21%, 20 and 33%, and 18 and 23%, respectively). After warming, blastocysts of greater size (II and III) showed significantly higher attachment (54 and 64%) and trophectoderm outgrowth (44 and 58%) rates than smaller blastocysts (I, attachment: 29%; trophectoderm outgrowth: 25%). These result demonstrate that denuded expanded or hatching rabbit blastocysts of greater size can be satisfactorily vitrified by use of a two-step procedure. The similarity of vitrification solutions used in humans could make it feasible to test such a procedure on human denuded blastocysts of different sizes.
Coskunseven, Efekan; Jankov, Mirko R; Grentzelos, Michael A; Plaka, Argyro D; Limnopoulou, Aliki N; Kymionis, George D
2013-01-01
To present the results of topography-guided transepithelial photorefractive keratectomy (PRK) after intracorneal ring segments implantation followed by corneal collagen cross-linking (CXL) for keratoconus. In this prospective case series, 10 patients (16 eyes) with progressive keratoconus were included. All patients underwent topography-guided transepithelial PRK after Keraring intracorneal ring segments (Mediphacos Ltda) implantation, followed by CXL treatment. The follow-up period was 6 months after the last procedure for all patients. Time interval between both intracorneal ring segments implantation and CXL and between CXL and topography-guided transepithelial PRK was 6 months. LogMAR mean uncorrected distance visual acuity and mean corrected distance visual acuity were significantly improved (P<.05) from 1.14±0.36 and 0.75±0.24 preoperatively to 0.25±0.13 and 0.13±0.06 after the completion of the three-step procedure, respectively. Mean spherical equivalent refraction was significantly reduced (P<.05) from -5.66±5.63 diopters (D) preoperatively to -0.98±2.21 D after the three-step procedure. Mean steep and flat keratometry values were significantly reduced (P<.05) from 54.65±5.80 D and 47.80±3.97 D preoperatively to 45.99±3.12 D and 44.69±3.19 D after the three-step procedure, respectively. Combined topography-guided transepithelial PRK with intracorneal ring segments implantation and CXL in a three-step procedure seems to be an effective, promising treatment sequence offering patients a functional visual acuity and ceasing progression of the ectatic disorder. A longer follow-up and larger case series are necessary to thoroughly evaluate safety, stability, and efficacy of this innovative procedure. Copyright 2013, SLACK Incorporated.
Checkout and Standard Use Procedures for the Mark III Space Suit Assembly
NASA Technical Reports Server (NTRS)
Valish, Dana J.
2012-01-01
The operational pressure range is the range to which the suit can be nominally operated for manned testing. The top end of the nominal operational pressure range is equivalent to 1/2 the proof pressure. Structural pressure is 1.5 times the specified test pressure for any given test. Proof pressure is the maximum unmanned pressure to which the suit was tested by the vendor prior to delivery. The maximum allowable working pressure (MAWP) is 90% of the proof pressure. The pressure systems RVs are set to keep components below their MAWPs. If the suit is pressurized over its MAWP, the suit will be taken out of service and an in-depth inspection/review of the suit will be performed before the suit is put back in service. The procedures outlined in this document should be followed as written. However, the suit test engineer (STE) may make redline changes real-time, provided those changes are recorded in the anomaly section of the test data sheet. If technicians supporting suit build-up, check-out, and/or test execution believe that a procedure can be improved, they should notify their lead. If procedures are incorrect to the point of potentially causing hardware damage or affecting safety, bring the problem to the technician lead and/or STE s attention and stop work until a solution (temporary or permanent) is authorized. Certain steps in the procedure are marked with a DV , for Designated Verifier. The Designated Verifier for this procedure is an Advanced Space Suit Technology Development Laboratory technician, not directly involved in performing the procedural steps, who will verify that the step was performed as stated. The steps to be verified by the DV were selected based on one or more of the following criteria: the step was deemed significant in ensuring the safe performance of the test, the data recorded in the step is of specific interest in monitoring the suit system operation, or the step has a strong influence on the successful completion of test objectives. Prior to all manned test activities, Advanced Suit Test Data Sheet (TDS) Parts A-E shall be completed to verify system and team are ready for test. Advanced Suit TDS Parts F-G shall be completed at the end of the suited activity. Appendix B identifies tha appropriate Mark III suit emergency event procedures.
Hazeleger, Wilma C; Jacobs-Reitsma, Wilma F; den Besten, Heidy M W
2016-01-01
Campylobacter is well recognized as the leading cause of bacterial foodborne diarrheal disease worldwide, and is routinely found in meat originating from poultry, sheep, pigs, and cattle. Effective monitoring of Campylobacter contamination is dependent on the availability of reliable detection methods. The method of the International Organization for Standardization for the detection of Campylobacter spp. in food (ISO 10272-1:2006) recommends the use of Bolton broth (BB) as selective enrichment medium, including a pre-enrichment step of 4-6 h at 37°C to revive sublethally damaged cells prior to incubation for 2 days at 41.5°C. Recently the presence of abundantly growing extended spectrum β-lactamase producing Enterobacteriaceae (ESBL bacteria) has become one of the most important factors that interfere with the isolation of Campylobacter, resulting in false-negative detection. However, detailed growth dynamics of Campylobacter and its competitors remain unclear, where these would provide a solid base for further improvement of the enrichment procedure for Campylobacter. Other enrichment broths, such as Preston broth (PB) and BB plus clavulanic acid (BBc) have been suggested to inhibit competitive flora. Therefore, these different broths were used as enrichments to measure the growth kinetics of several strains of Campylobacter jejuni and ESBL bacteria separately, in co-culture and of strains in chicken samples. The maximum cell numbers and often the growth rates of Campylobacter in mixed culture with ESBL bacteria were significantly lower than in single cultures, indicating severe suppression of Campylobacter by ESBL bacteria, also in naturally contaminated samples. PB and BBc successfully diminished ESBL bacteria and might therefore be a better choice as enrichment medium in possibly ESBL-bacteria contaminated samples. The efficacy of a pre-enrichment step in the BB ISO-procedure was not supported for cold-stressed and non-stressed cells. Therefore, omission of this step (4-6 h at 37°C) might be advised to obtain a less troublesome protocol.
Berkowitz, Lori R; James, Kaitlyn; Petrusa, Emil; York-Best, Carey; Kaimal, Anjali J
2018-02-05
To describe the development of a low-cost educational module for OB/GYN faculty skills maintenance for total abdominal hysterectomy (TAH), a low frequency core procedure in obstetrics and gynecology. After review of existing educational tools and utilization of a modified Delphi method to establish consensus regarding key procedural components for skills maintenance, a 2-hour workshop was developed to review knowledge and participate in a simulation focused on the critical steps in performing TAH. An expert in TAH delivered a lecture highlighting important surgical considerations. Participants then rotated through simulation stations for critical steps in TAH: dissecting the bladder, identifying the ureter, and closing the cuff. Knowledge gains were assessed with a written pre- and posttest. Consecutive focus groups were conducted with participants on effectiveness of the workshop, and suggestions for improvement. Ideas identified in the first focus group were incorporated into the second workshop. Massachusetts General Hospital, an academic tertiary care facility with a single Obstetrics and Gynecology faculty group, located in Boston, Massachusetts. Eligible participants were recruited via email from full time specialists in General Obstetrics and Gynecology at Massachusetts General Hospital. Of the 25 eligible gynecology faculty subjects, 22 participated (88%). On pre or post-test comparison, 70% of participants scored higher on the posttest, demonstrating an increase in knowledge of critical TAH surgical steps. Focus group analyses identified the need for increased review and training demonstrations of TAH, and recommended continued offering of the workshop. Based on focus group responses and pre or posttest comparisons, the workshop was deemed feasible and enhanced short-term learning. Future directions include utilizing more challenging anatomic models and simulation scenarios and optimizing integration of expert demonstration and individualized coaching, as well as identifying regionally tailored surgical workshop programming. Copyright © 2018 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.
On large time step TVD scheme for hyperbolic conservation laws and its efficiency evaluation
NASA Astrophysics Data System (ADS)
Qian, ZhanSen; Lee, Chun-Hian
2012-08-01
A large time step (LTS) TVD scheme originally proposed by Harten is modified and further developed in the present paper and applied to Euler equations in multidimensional problems. By firstly revealing the drawbacks of Harten's original LTS TVD scheme, and reasoning the occurrence of the spurious oscillations, a modified formulation of its characteristic transformation is proposed and a high resolution, strongly robust LTS TVD scheme is formulated. The modified scheme is proven to be capable of taking larger number of time steps than the original one. Following the modified strategy, the LTS TVD schemes for Yee's upwind TVD scheme and Yee-Roe-Davis's symmetric TVD scheme are constructed. The family of the LTS schemes is then extended to multidimensional by time splitting procedure, and the associated boundary condition treatment suitable for the LTS scheme is also imposed. The numerical experiments on Sod's shock tube problem, inviscid flows over NACA0012 airfoil and ONERA M6 wing are performed to validate the developed schemes. Computational efficiencies for the respective schemes under different CFL numbers are also evaluated and compared. The results reveal that the improvement is sizable as compared to the respective single time step schemes, especially for the CFL number ranging from 1.0 to 4.0.
Suggested Best Practice for seismic monitoring and characterization of non-conventional reservoirs
NASA Astrophysics Data System (ADS)
Malin, P. E.; Bohnhoff, M.; terHeege, J. H.; Deflandre, J. P.; Sicking, C.
2017-12-01
High rates of induced seismicity and gas leakage in non-conventional production have become a growing issue of public concern. It has resulted in calls for independent monitoring before, during and after reservoir production. To date no uniform practice for it exists and few reservoirs are locally monitored at all. Nonetheless, local seismic monitoring is a pre-requisite for detecting small earthquakes, increases of which can foreshadow damaging ones and indicate gas leaks. Appropriately designed networks, including seismic reflection studies, can be used to collect these and Seismic Emission Tomography (SET) data, the latter significantly helping reservoir characterization and exploitation. We suggest a Step-by-Step procedure for implementing such networks. We describe various field kits, installations, and workflows, all aimed at avoiding damaging seismicity, as indicators of well stability, and improving reservoir exploitation. In Step 1, a single downhole seismograph is recommended for establishing baseline seismicity before development. Subsequent Steps are used to decide cost-effective ways of monitoring treatments, production, and abandonment. We include suggestions for monitoring of disposal and underground storage. We also describe how repeated SET observations improve reservoir management as well as regulatory monitoring. Moreover, SET acquisition can be included at incremental cost in active surveys or temporary passive deployments.
Prediction of composite thermal behavior made simple
NASA Technical Reports Server (NTRS)
Chamis, C. C.
1981-01-01
A convenient procedure is described to determine the thermal behavior (thermal expansion coefficients and thermal stresses) of angleplied fiber composites using a pocket calculator. The procedure consists of equations and appropriate graphs for various ( + or - theta) ply combinations. These graphs present reduced stiffness and thermal expansion coefficients as functions of (+ or - theta) in order to simplify and expedite the use of the equations. The procedure is applicable to all types of balanced, symmetric fiber composites including interply and intraply hybrids. The versatility and generality of the procedure is illustrated using several step-by-step numerical examples.
Kim, Hong-Seok; Choi, Dasom; Kang, Il-Byeong; Kim, Dong-Hyeon; Yim, Jin-Hyeok; Kim, Young-Ji; Chon, Jung-Whan; Oh, Deog-Hwan; Seo, Kun-Ho
2017-02-01
Culture-based detection of nontyphoidal Salmonella spp. in foods requires at least four working days; therefore, new detection methods that shorten the test time are needed. In this study, we developed a novel single-step Salmonella enrichment broth, SSE-1, and compared its detection capability with that of commercial single-step ONE broth-Salmonella (OBS) medium and a conventional two-step enrichment method using buffered peptone water and Rappaport-Vassiliadis soy broth (BPW-RVS). Minimally processed lettuce samples were artificially inoculated with low levels of healthy and cold-injured Salmonella Enteritidis (10 0 or 10 1 colony-forming unit/25 g), incubated in OBS, BPW-RVS, and SSE-1 broths, and streaked on xylose lysine deoxycholate (XLD) agar. Salmonella recoverability was significantly higher in BPW-RVS (79.2%) and SSE-1 (83.3%) compared to OBS (39.3%) (p < 0.05). Our data suggest that the SSE-1 single-step enrichment broth could completely replace two-step enrichment with reduced enrichment time from 48 to 24 h, performing better than commercial single-step enrichment medium in the conventional nonchromogenic Salmonella detection, thus saving time, labor, and cost.
Jenkins, T C; Thies, E J; Mosley, E E
2001-05-01
Two direct methylation procedures often used for the analysis of total fatty acids in biological samples were evaluated for their application to samples containing fatty amides. Methylation of 5 mg of oleamide (cis-9-octadecenamide) in a one-step (methanolic HCl for 2 h at 70 degrees C) or a two-step (sodium methoxide for 10 min at 50 degrees C followed by methanolic HCl for 10 min at 80 degrees C) procedure gave 59 and 16% conversions of oleamide to oleic acid, respectively. Oleic acid recovery from oleamide was increased to 100% when the incubation in methanolic HCl was lengthened to 16 h and increased to 103% when the incubation in methoxide was modified to 24 h at 100 degrees C. However, conversion of oleamide to oleic acid in an animal feed sample was incomplete for the modified (24 h) two-step procedure but complete for the modified (16 h) one-step procedure. Unsaturated fatty amides in feed and digesta samples can be converted to fatty acid methyl esters by incubation in methanolic HCl if the time of exposure to the acid catalyst is extended from 2 to 16 h.
Qualitative computer aided evaluation of dental impressions in vivo.
Luthardt, Ralph G; Koch, Rainer; Rudolph, Heike; Walter, Michael H
2006-01-01
Clinical investigations dealing with the precision of different impression techniques are rare. Objective of the present study was to develop and evaluate a procedure for the qualitative analysis of the three-dimensional impression precision based on an established in-vitro procedure. The zero hypothesis to be tested was that the precision of impressions does not differ depending on the impression technique used (single-step, monophase and two-step-techniques) and on clinical variables. Digital surface data of patient's teeth prepared for crowns were gathered from standardized manufactured master casts after impressions with three different techniques were taken in a randomized order. Data-sets were analyzed for each patient in comparison with the one-step impression chosen as the reference. The qualitative analysis was limited to data-points within the 99.5%-range. Based on the color-coded representation areas with maximum deviations were determined (preparation margin and the mantle and occlusal surface). To qualitatively analyze the precision of the impression techniques, the hypothesis was tested in linear models for repeated measures factors (p < 0.05). For the positive 99.5% deviations no variables with significant influence were determined in the statistical analysis. In contrast, the impression technique and the position of the preparation margin significantly influenced the negative 99.5% deviations. The influence of clinical parameter on the deviations between impression techniques can be determined reliably using the 99.5 percentile of the deviations. An analysis regarding the areas with maximum deviations showed high clinical relevance. The preparation margin was pointed out as the weak spot of impression taking.
Faria, Eliney F; Caputo, Peter A; Wood, Christopher G; Karam, Jose A; Nogueras-González, Graciela M; Matin, Surena F
2014-02-01
Laparoscopic and robotic partial nephrectomy (LPN and RPN) are strongly related to influence of tumor complexity and learning curve. We analyzed a consecutive experience between RPN and LPN to discern if warm ischemia time (WIT) is in fact improved while accounting for these two confounding variables and if so by which particular aspect of WIT. This is a retrospective analysis of consecutive procedures performed by a single surgeon between 2002-2008 (LPN) and 2008-2012 (RPN). Specifically, individual steps, including tumor excision, suturing of intrarenal defect, and parenchyma, were recorded at the time of surgery. Multivariate and univariate analyzes were used to evaluate influence of learning curve, tumor complexity, and time kinetics of individual steps during WIT, to determine their influence in WIT. Additionally, we considered the effect of RPN on the learning curve. A total of 146 LPNs and 137 RPNs were included. Considering renal function, WIT, suturing time, renorrhaphy time were found statistically significant differences in favor of RPN (p < 0.05). In the univariate analysis, surgical procedure, learning curve, clinical tumor size, and RENAL nephrometry score were statistically significant predictors for WIT (p < 0.05). RPN decreased the WIT on average by approximately 7 min compared to LPN even when adjusting for learning curve, tumor complexity, and both together (p < 0.001). We found RPN was associated with a shorter WIT when controlling for influence of the learning curve and tumor complexity. The time required for tumor excision was not shortened but the time required for suturing steps was significantly shortened.
Fabbretti, G
2010-06-01
Because of its complex nature, surgical pathology practice is prone to error. In this report, we describe our methods for reducing error as much as possible during the pre-analytical and analytical phases. This was achieved by revising procedures, and by using computer technology and automation. Most mistakes are the result of human error in the identification and matching of patient and samples. To avoid faulty data interpretation, we employed a new comprehensive computer system that acquires all patient ID information directly from the hospital's database with a remote order entry; it also provides label and request forms via-Web where clinical information is required before sending the sample. Both patient and sample are identified directly and immediately at the site where the surgical procedures are performed. Barcode technology is used to input information at every step and automation is used for sample blocks and slides to avoid errors that occur when information is recorded or transferred by hand. Quality control checks occur at every step of the process to ensure that none of the steps are left to chance and that no phase is dependent on a single operator. The system also provides statistical analysis of errors so that new strategies can be implemented to avoid repetition. In addition, the staff receives frequent training on avoiding errors and new developments. The results have been shown promising results with a very low error rate (0.27%). None of these compromised patient health and all errors were detected before the release of the diagnosis report.
Sampaio, P N; Pais, M S; Fonseca, L P
2014-12-01
Nowadays, the dairy industry is continuously looking for new and more efficient clotting enzymes to create innovative products. Cyprosin B is a plant aspartic protease characterized by clotting activity that was previously cloned in Saccharomyces cerevisiae BJ1991 strain. The production of recombinant cyprosin B by a batch and fed-batch culture was compared using glucose and galactose as carbon sources. The strategy for fed-batch cultivation involved two steps: in the first batch phase, the culture medium presented glucose 1 % (w/v) and galactose 0.5 % (w/v), while in the feed step the culture medium was constituted by 5 % (w/v) galactose with the aim to minimize the GAL7 promoter repression. Based on fed-batch, in comparison to batch growth, an increase in biomass (6.6-fold), protein concentration (59 %) and cyprosin B activity (91 %) was achieved. The recombinant cyprosin B was purified by a single hydrophobic chromatography, presenting a specific activity of 6 × 10(4) U·mg(-1), corresponding to a purification degree of 12.5-fold and a recovery yield of 16.4 %. The SDS-PAGE analysis showed that recovery procedure is suitable for achieving the purified recombinant cyprosin B. The results show that the recombinant cyprosin B production can be improved based on two distinct steps during the fed-batch, presenting that this strategy, associated with a simplified purification procedure, could be applied to large-scale production, constituting a new and efficient alternative for animal and fungal enzymes widely used in cheese making.
Zhao, Wenle; Pauls, Keith
2016-04-01
Centralized outcome adjudication has been used widely in multicenter clinical trials in order to prevent potential biases and to reduce variations in important safety and efficacy outcome assessments. Adjudication procedures could vary significantly among different studies. In practice, the coordination of outcome adjudication procedures in many multicenter clinical trials remains as a manual process with low efficiency and high risk of delay. Motivated by the demands from two large clinical trial networks, a generic outcome adjudication module has been developed by the network's data management center within a homegrown clinical trial management system. In this article, the system design strategy and database structure are presented. A generic database model was created to transfer different adjudication procedures into a unified set of sequential adjudication steps. Each adjudication step was defined by one activate condition, one lock condition, one to five categorical data items to capture adjudication results, and one free text field for general comments. Based on this model, a generic outcome adjudication user interface and a generic data processing program were developed within a homegrown clinical trial management system to provide automated coordination of outcome adjudication. By the end of 2014, this generic outcome adjudication module had been implemented in 10 multicenter trials. A total of 29 adjudication procedures were defined with the number of adjudication steps varying from 1 to 7. The implementation of a new adjudication procedure in this generic module took an experienced programmer 1 or 2 days. A total of 7336 outcome events had been adjudicated and 16,235 adjudication step activities had been recorded. In a multicenter trial, 1144 safety outcome event submissions went through a three-step adjudication procedure and reported a median of 3.95 days from safety event case report form submission to adjudication completion. In another trial, 277 clinical outcome events were adjudicated by a six-step procedure and took a median of 23.84 days from outcome event case report form submission to adjudication procedure completion. A generic outcome adjudication module integrated in the clinical trial management system made the automated coordination of efficacy and safety outcome adjudication a reality. © The Author(s) 2015.
Formalizing the Austrian Procedure Catalogue: A 4-step methodological analysis approach.
Neururer, Sabrina Barbara; Lasierra, Nelia; Peiffer, Karl Peter; Fensel, Dieter
2016-04-01
Due to the lack of an internationally accepted and adopted standard for coding health interventions, Austria has established its own country-specific procedure classification system - the Austrian Procedure Catalogue (APC). Even though the APC is an elaborate coding standard for medical procedures, it has shortcomings that limit its usability. In order to enhance usability and usefulness, especially for research purposes and e-health applications, we developed an ontologized version of the APC. In this paper we present a novel four-step approach for the ontology engineering process, which enables accurate extraction of relevant concepts for medical ontologies from written text. The proposed approach for formalizing the APC consists of the following four steps: (1) comparative pre-analysis, (2) definition analysis, (3) typological analysis, and (4) ontology implementation. The first step contained a comparison of the APC to other well-established or elaborate health intervention coding systems in order to identify strengths and weaknesses of the APC. In the second step, a list of definitions of medical terminology used in the APC was obtained. This list of definitions was used as input for Step 3, in which we identified the most important concepts to describe medical procedures using the qualitative typological analysis approach. The definition analysis as well as the typological analysis are well-known and effective methods used in social sciences, but not commonly employed in the computer science or ontology engineering domain. Finally, this list of concepts was used in Step 4 to formalize the APC. The pre-analysis highlighted the major shortcomings of the APC, such as the lack of formal definition, leading to implicitly available, but not directly accessible information (hidden data), or the poor procedural type classification. After performing the definition and subsequent typological analyses, we were able to identify the following main characteristics of health interventions: (1) Procedural type, (2) Anatomical site, (3) Medical device, (4) Pathology, (5) Access, (6) Body system, (7) Population, (8) Aim, (9) Discipline, (10) Technique, and (11) Body Function. These main characteristics were taken as input of classes for the formalization of the APC. We were also able to identify relevant relations between classes. The proposed four-step approach for formalizing the APC provides a novel, systematically developed, strong framework to semantically enrich procedure classifications. Although this methodology was designed to address the particularities of the APC, the included methods are based on generic analysis tasks, and therefore can be re-used to provide a systematic representation of other procedure catalogs or classification systems and hence contribute towards a universal alignment of such representations, if desired. Copyright © 2015 Elsevier Inc. All rights reserved.
Zhong, Xiao; Wang, Pingxian; Feng, Jiayu; Hu, Wengang; Huang, Chibing
2015-01-01
This randomized controlled study compared a novel transparent urinary tract simulator with the traditional opaque urinary tract simulator as an aid for efficiently teaching urological surgical procedures. Senior medical students were tested on their understanding of urological theory before and after lectures concerning urinary system disease. The students received operative training using the transparent urinary tract simulator (experimental group, n = 80) or the J3311 opaque plastic urinary tract simulator (control, n = 80), specifically in catheterization and retrograde double-J stent implantation. The operative training was followed by a skills test and student satisfaction survey. The test scores for theory were similar between the two groups, before and after training. Students in the experimental group performed significantly better than those in the control group on the procedural skills test, and also had significantly better self-directed learning skills, analytical skills, and greater motivation to learn. During the initial step of training, the novel transparent urinary tract simulator significantly improved the efficiency of teaching urological procedural skills compared with the traditional opaque device. © 2015 S. Karger AG, Basel.
8s, a numerical simulator of the challenging optical calibration of the E-ELT adaptive mirror M4
NASA Astrophysics Data System (ADS)
Briguglio, Runa; Pariani, Giorgio; Xompero, Marco; Riccardi, Armando; Tintori, Matteo; Lazzarini, Paolo; Spanò, Paolo
2016-07-01
8s stands for Optical Test TOwer Simulator (with 8 read as in italian 'otto'): it is a simulation tool for the optical calibration of the E-ELT deformable mirror M4 on its test facility. It has been developed to identify possible criticalities in the procedure, evaluate the solutions and estimate the sensitivity to environmental noise. The simulation system is composed by the finite elements model of the tower, the analytic influence functions of the actuators, the ray tracing propagation of the laser beam through the optical surfaces. The tool delivers simulated phasemaps of M4, associated with the current system status: actuator commands, optics alignment and position, beam vignetting, bench temperature and vibrations. It is possible to simulate a single step of the optical test of M4 by changing the system parameters according to a calibration procedure and collect the associated phasemap for performance evaluation. In this paper we will describe the simulation package and outline the proposed calibration procedure of M4.
Design procedures for fiber composite box beams
NASA Technical Reports Server (NTRS)
Chamis, Cristos C.; Murthy, Pappu L. N.
1989-01-01
Step-by-step procedures are described which can be used for the preliminary design of fiber composite box beams subjected to combined loadings. These procedures include a collection of approximate closed-form equations so that all the required calculations can be performed using pocket calculators. Included is an illustrative example of a tapered cantilever box beam subjected to combined loads. The box beam is designed to satisfy strength, displacement, buckling, and frequency requirements.
Design Procedures for Fiber Composite Box Beams
NASA Technical Reports Server (NTRS)
Chamis, Christos C.; Murthy, Pappu L. N.
1988-01-01
Step-by-step procedures are described which can be used for the preliminary design of fiber composite box beams subjected to combined loadings. These procedures include a collection of approximate closed-form equations so that all the required calculations can be performed using pocket calculators. Included is an illustrated example of a tapered cantilever box beam subjected to combined loads. The box beam is designed to satisfy strength, displacement, buckling, and frequency requirements.
Effluent Monitoring Procedures: Nutrients. Student Reference Manual.
ERIC Educational Resources Information Center
Environmental Protection Agency, Washington, DC. Office of Water Programs.
This is one of several short-term courses developed to assist in the training of waste water treatment plant operational personnel in the tests, measurements, and report preparation required for compliance with their NPDES Permits. The Student Reference Manual provides step-by-step procedures for laboratory application of equipment operating…
Effluent Monitoring Procedures: Metals Analyses. Student Reference Manual.
ERIC Educational Resources Information Center
Environmental Protection Agency, Washington, DC. Office of Water Programs.
This is one of several short-term courses developed to assist in the training of waste water treatment plant operational personnel in the tests, measurements, and report preparation required for compliance with their NPDES Permits. The Student Reference Manual provides step-by-step procedures for laboratory application of equipment operating…
The American University Hotline: Manual for Trainers.
ERIC Educational Resources Information Center
Krieger, Howard; And Others
The philosophy, rationale, and specific training procedures of the American University Hotline are detailed in this trainer's manual. The manual provides a step-by-step discussion of training procedures implemented in a student-operated university hotline telephone service. The training package, widely disseminated over the past six years, has…
Design of a Compact Quad-Channel Diplexer
NASA Astrophysics Data System (ADS)
Xu, Jin
2016-01-01
This paper presents a compact quad-channel diplexer by using two asymmetrical coupling shorted stub loaded stepped-impedance (SSLSIR) dual-band bandpass filters (DB-BPFs) to replace two single-band BPFs in a traditional BPF-based diplexer. Part of its impedance matching circuit is implemented by using a three-element lowpass T-network to acquire the desired phase shift. Detailed design procedures are given to guide the diplexer design. The fabricated quad-channel diplexer occupies a compact circuit area of 0.168λg×0.136λg. High band-to-band isolation and wide stopband performance are achieved. Good agreement is shown between the simulated and measured results.
An improved method to unravel phosphoacceptors in Ser/Thr protein kinase-phosphorylated substrates.
Molle, Virginie; Leiba, Jade; Zanella-Cléon, Isabelle; Becchi, Michel; Kremer, Laurent
2010-11-01
Identification of the phosphorylated residues of bacterial Ser/Thr protein kinase (STPK) substrates still represents a challenging task. Herein, we present a new strategy allowing the rapid determination of phosphoacceptors in kinase substrates, essentially based on the dual expression of the kinase with its substrate in the surrogate E. coli, followed by MS analysis in a single-step procedure. The performance of this strategy is illustrated using two distinct proteins from Mycobacterium tuberculosis as model substrates, the GroEL2 and HspX chaperones. A comparative analysis with a standard method that includes mass spectrometry analysis of in vitro phosphorylated substrates is also addressed.
Modeling Woven Polymer Matrix Composites with MAC/GMC
NASA Technical Reports Server (NTRS)
Bednarcyk, Brett A.; Arnold, Steven M. (Technical Monitor)
2000-01-01
NASA's Micromechanics Analysis Code with Generalized Method of Cells (MAC/GMC) is used to predict the elastic properties of plain weave polymer matrix composites (PMCs). The traditional one step three-dimensional homogertization procedure that has been used in conjunction with MAC/GMC for modeling woven composites in the past is inaccurate due to the lack of shear coupling inherent to the model. However, by performing a two step homogenization procedure in which the woven composite repeating unit cell is homogenized independently in the through-thickness direction prior to homogenization in the plane of the weave, MAC/GMC can now accurately model woven PMCs. This two step procedure is outlined and implemented, and predictions are compared with results from the traditional one step approach and other models and experiments from the literature. Full coupling of this two step technique with MAC/ GMC will result in a widely applicable, efficient, and accurate tool for the design and analysis of woven composite materials and structures.
The stepping behavior analysis of pedestrians from different age groups via a single-file experiment
NASA Astrophysics Data System (ADS)
Cao, Shuchao; Zhang, Jun; Song, Weiguo; Shi, Chang'an; Zhang, Ruifang
2018-03-01
The stepping behavior of pedestrians with different age compositions in single-file experiment is investigated in this paper. The relation between step length, step width and stepping time are analyzed by using the step measurement method based on the calculation of curvature of the trajectory. The relations of velocity-step width, velocity-step length and velocity-stepping time for different age groups are discussed and compared with previous studies. Finally effects of pedestrian gender and height on stepping laws and fundamental diagrams are analyzed. The study is helpful for understanding pedestrian dynamics of movement. Meanwhile, it offers experimental data to develop a microscopic model of pedestrian movement by considering stepping behavior.
Rapid step-gradient purification of mitochondrial DNA.
Welter, C; Meese, E; Blin, N
1988-01-01
A convenient modification of the step gradient (CsCl/ethidium bomide) procedure is described. This rapid method allows isolation of covalently closed circular DNA separated from contaminating proteins, RNA and chromosomal DNA in ca. 5 h. Large scale preparations can be performed for circular DNA from eukaryotic organelles (mitochondria). The protocol uses organelle pelleting/NaCl-sarcosyl incubation steps for mitochondria followed by a CsCl step gradient and exhibits yields equal to the conventional procedures. It results in DNA sufficiently pure to be used for restriction endonuclease analysis, subcloning, 5'-end labeling, gel retention assays, and various types of hybridization.
Treatment of congenital anophthalmos with self-inflating polymer expanders: a new method.
Wiese, K G; Vogel, M; Guthoff, R; Gundlach, K K
1999-04-01
Congenital anophthalmos is a rare malformation in which the optic vesicle fails to develop. This leads to a small bony orbit, a constricted mucosal socket, short eyelids, reduced palpebral fissure and malar hypoplasia. The treatment includes both aesthetic and functional aspects. Therefore, a two-step procedure is described using a new self-inflating hydrogel expander. A lens-shaped expander with a diameter of 8 mm expands the lids and the mucosal socket to allow insertion of an eye prosthesis. As a second step, orbital expansion is performed with a spherical device. The expanders absorb lacrimal fluid from the mucosal socket or tissue fluid and start swelling when implanted in the orbital tissue. The insertion of an expander into the orbit as well as into the conjunctival pocket including its fixation by a single suture took only a few minutes and was an easy procedure. The expansion of the small conjunctival sockets was successfully completed in all cases within a period of 2-4 weeks. The weight (= volume in ml) of devices increased from 0.15-1.5 g (lens-shaped expander; weight in grams = volume in ml) respectively, 0.3-3.5 g (spherical device). The expanders inserted in orbital tissue increased from 0.4-4.4 g. This is equivalent to a 10 to 11 fold increase in their water-free volumes. Orbital expansion with spherical devices in combination with the inserted eye prosthesis enlarges the lid and palpebral fissures also. In contrast to conventional silicon balloon expanders, the procedure using self-inflating hydrogel expanders is simple and highly efficient.
Co-delivery of ibuprofen and gentamicin from nanoporous anodic titanium dioxide layers.
Pawlik, Anna; Jarosz, Magdalena; Syrek, Karolina; Sulka, Grzegorz D
2017-04-01
Although single-drug therapy may prove insufficient in treating bacterial infections or inflammation after orthopaedic surgeries, complex therapy (using both an antibiotic and an anti-inflammatory drug) is thought to address the problem. Among drug delivery systems (DDSs) with prolonged drug release profiles, nanoporous anodic titanium dioxide (ATO) layers on Ti foil are very promising. In the discussed research, ATO samples were synthesized via a three-step anodization process in an ethylene glycol-based electrolyte with fluoride ions. The third step lasted 2, 5 and 10min in order to obtain different thicknesses of nanoporous layers. Annealing the as-prepared amorphous layers at the temperature of 400°C led to obtaining the anatase phase. In this study, water-insoluble ibuprofen and water-soluble gentamicin were used as model drugs. Three different drug loading procedures were applied. The desorption-desorption-diffusion (DDD) model of the drug release was fitted to the experimental data. The effects of crystalline structure, depth of TiO 2 nanopores and loading procedure on the drug release profiles were examined. The duration of the drug release process can be easily altered by changing the drug loading sequence. Water-soluble gentamicin is released for a long period of time if gentamicin is loaded in ATO as the first drug. Additionally, deeper nanopores and anatase phase suppress the initial burst release of drugs. These results confirm that factors such as morphological and crystalline structure of ATO layers, and the procedure of drug loading inside nanopores, allow to alter the drug release performance of nanoporous ATO layers. Copyright © 2017 Elsevier B.V. All rights reserved.
Double-Sided Single-Pass Submerged Arc Welding for 2205 Duplex Stainless Steel
NASA Astrophysics Data System (ADS)
Luo, Jian; Yuan, Yi; Wang, Xiaoming; Yao, Zongxiang
2013-09-01
The duplex stainless steel (DSS), which combines the characteristics of ferritic steel and austenitic steel, is used widely. The submerged arc welding (SAW) method is usually applied to join thick plates of DSS. However, an effective welding procedure is needed in order to obtain ideal DSS welds with an appropriate proportion of ferrite (δ) and austenite (γ) in the weld zone, particularly in the melted zone and heat-affected zone. This study evaluated the effectiveness of a high efficiency double-sided single-pass (DSSP) SAW joining method for thick DSS plates. The effectiveness of the converse welding procedure, characterizations of weld zone, and mechanical properties of welded joint are analyzed. The results show an increasing appearance and continuous distribution feature of the σ phase in the fusion zone of the leading welded seam. The converse welding procedure promotes the σ phase to precipitate in the fusion zone of leading welded side. The microhardness appears to significantly increase in the center of leading welded side. Ductile fracture mode is observed in the weld zone. A mixture fracture feature appears with a shear lip and tears in the fusion zone near the fusion line. The ductility, plasticity, and microhardness of the joints have a significant relationship with σ phase and heat treatment effect influenced by the converse welding step. An available heat input controlling technology of the DSSP formation method is discussed for SAW of thick DSS plates.
Mechanochemical synthesis of high thermoelectric performance bulk Cu 2X (X = S, Se) materials
Yang, Dongwang; Su, Xianli; Yan, Yonggao; ...
2016-11-01
We devised a single-step mechanochemical synthesis/densification procedure for Cu 2X (X = S, Se) thermoelectric materials via applying a pressure of 3 GPa to a stoichiometric admixture of elemental Cu and X for 3 min at room temperature. The obtained bulk materials were single-phase, nearly stoichiometric structures with a relative packing density of 97% or higher. The structures contained high concentration of atomic scale defects and pores of 20-200 nm diameter. The above attributes gave rise to a high thermoelectric performance: at 873 K, the ZT value of Cu2S reached 1.07, about 2.1 times the value typical of samples grownmore » from the melt. The ZT value of Cu 2Se samples reached in excess of 1.2, close to the state-of-the-art value.« less
Yegin, Sirma
2017-04-15
An extracellular xylanase from Aureobasidium pullulans NRRL Y-2311-1 produced on wheat bran was purified by a single-step chromatographic procedure. The enzyme had a molecular weight of 21.6kDa. The optimum pH and temperature for xylanase activity were 4.0 and 30-50°C, respectively. The enzyme was stable in the pH range of 3.0-8.0. The inactivation energy of the enzyme was calculated as 218kJmol -1 . The xylanase was ethanol tolerant and kept complete activity in the presence of 10% ethanol. Likewise, it retained almost complete activity at a concentration range of 0-20% NaCl. In general, the enzyme was resistant to several metal ions and reagents. Mg 2+ , Zn 2+ , Cu 2+ , K 1+ , EDTA and β-mercaptoethanol resulted in enhanced xylanase activity. The K m and V max values on beechwood xylan were determined to be 19.43mgml -1 and 848.4Uml -1 , respectively. The enzyme exhibits excellent characteristics and could, therefore, be a promising candidate for application in food and bio-industries. Copyright © 2016 Elsevier Ltd. All rights reserved.
Fully integrated lab-on-a-disc for nucleic acid analysis of food-borne pathogens.
Kim, Tae-Hyeong; Park, Juhee; Kim, Chi-Ju; Cho, Yoon-Kyoung
2014-04-15
This paper describes a micro total analysis system for molecular analysis of Salmonella, a major food-borne pathogen. We developed a centrifugal microfluidic device, which integrated the three main steps of pathogen detection, DNA extraction, isothermal recombinase polymerase amplification (RPA), and detection, onto a single disc. A single laser diode was utilized for wireless control of valve actuation, cell lysis, and noncontact heating in the isothermal amplification step, thereby yielding a compact and miniaturized system. To achieve high detection sensitivity, rare cells in large volumes of phosphate-buffered saline (PBS) and milk samples were enriched before loading onto the disc by using antibody-coated magnetic beads. The entire procedure, from DNA extraction through to detection, was completed within 30 min in a fully automated fashion. The final detection was carried out using lateral flow strips by direct visual observation; detection limit was 10 cfu/mL and 10(2) cfu/mL in PBS and milk, respectively. Our device allows rapid molecular diagnostic analysis and does not require specially trained personnel or expensive equipment. Thus, we expect that it would have an array of potential applications, including in the detection of food-borne pathogens, environmental monitoring, and molecular diagnostics in resource-limited settings.
Tsuchiya, Kenji; Takamizawa, Toshiki; Barkmeier, Wayne W; Tsubota, Keishi; Tsujimoto, Akimasa; Berry, Thomas P; Erickson, Robert L; Latta, Mark A; Miyazaki, Masashi
2016-02-01
The present study aimed to determine the effect of the functional monomer, 10-methacryloxydecyl dihydrogen phosphate (MDP), on the enamel bond durability of single-step self-etch adhesives through integrating fatigue testing and long-term water storage. An MDP-containing self-etch adhesive, Clearfil Bond SE ONE (SE), and an experimental adhesive, MDP-free (MF), which comprised the same ingredients as SE apart from MDP, were used. Shear bond strength (SBS) and shear fatigue strength (SFS) were measured with or without phosphoric acid pre-etching. The specimens were stored in distilled water for 24 h, 6 months, or 1 yr. Although similar SBS and SFS values were obtained for SE with pre-etching and for MF after 24 h of storage in distilled water, SE with pre-etching showed higher SBS and SFS values than MF after storage in water for 6 months or 1 yr. Regardless of the pre-etching procedure, SE showed higher SBS and SFS values after 6 months of storage in distilled water than after 24 h or 1 yr. To conclude, MDP might play an important role in enhancing not only bond strength but also bond durability with respect to repeated subcritical loading after long-term water storage. © 2015 Eur J Oral Sci.
Azcarate, Silvana M; Savio, Marianela; Smichowski, Patricia; Martinez, Luis D; Camiña, José M; Gil, Raúl A
2015-10-01
A single-step procedure for trace elements analysis of milk samples is presented. Solubilization with small amounts of dymethylformamide (DMF) was assayed prior to inductively coupled plasma mass spectrometry (ICPMS) detection with a high efficiency sample introduction system. All main instrumental conditions were optimized in order to readily introduce the samples without matrix elimination. In order to assess and mitigate matrix effects in the determination of As, Cd, Co, Cu, Eu, Ga, Gd, Ge, Mn, Mo, Nb, Nd, Ni, Pb, Pr, Rb, Sm, S, Sr, Ta, Tb, V, Zn, and Zr, matrix matching calibration with (103)Rh as internal standard (IS) was performed. The obtained limits of detection were between 0.68 (Tb) and 30 (Zn) μg L(-1). For accuracy verification, certified Skim milk powder reference material (BCR 063R) was employed. The developed method was applied to trace elements analysis of commercially available milks. Principal components analysis was used to correlate the content of trace metals with the kind of milk, obtaining a classification according to adults, baby or baby fortified milks. The outcomes highlight a simple and fast approach that could be trustworthy for routine analysis, quality control and traceability of milks. Copyright © 2015 Elsevier B.V. All rights reserved.
Clinical assessment of spatiotemporal gait parameters in patients and older adults.
Item-Glatthorn, Julia F; Maffiuletti, Nicola A
2014-11-07
Spatial and temporal characteristics of human walking are frequently evaluated to identify possible gait impairments, mainly in orthopedic and neurological patients, but also in healthy older adults. The quantitative gait analysis described in this protocol is performed with a recently-introduced photoelectric system (see Materials table) which has the potential to be used in the clinic because it is portable, easy to set up (no subject preparation is required before a test), and does not require maintenance and sensor calibration. The photoelectric system consists of series of high-density floor-based photoelectric cells with light-emitting and light-receiving diodes that are placed parallel to each other to create a corridor, and are oriented perpendicular to the line of progression. The system simply detects interruptions in light signal, for instance due to the presence of feet within the recording area. Temporal gait parameters and 1D spatial coordinates of consecutive steps are subsequently calculated to provide common gait parameters such as step length, single limb support and walking velocity, whose validity against a criterion instrument has recently been demonstrated. The measurement procedures are very straightforward; a single patient can be tested in less than 5 min and a comprehensive report can be generated in less than 1 min.
Sher Shah, Md Selim Arif; Zhang, Kan; Park, A Reum; Kim, Kwang Su; Park, Nam-Gyu; Park, Jong Hyeok; Yoo, Pil J
2013-06-07
With growing interest in the photocatalytic performance of TiO2-graphene composite systems, the ternary phase of TiO2, graphene, and Ag is expected to exhibit improved photocatalytic characteristics because of the improved recombination rate of photogenerated charge carriers and potential contribution of the generation of localized surface plasmon resonance at Ag sites on a surface of the TiO2-graphene binary matrix. In this work, Ag-TiO2-reduced graphene oxide ternary nanocomposites were successfully synthesized by a simple solvothermal process. In a single-step synthetic procedure, the reduction of AgNO3 and graphene oxide and the hydrolysis of titanium tetraisopropoxide were spontaneously performed in a mixed solvent system of ethylene glycol, N,N-dimethylformamide and a stoichiometric amount of water without resorting to the use of typical reducing agents. The nanocomposites were characterized by X-ray diffraction, X-ray photoelectron spectroscopy, along with different microscopic and spectroscopic techniques, enabling us to confirm the successful reduction of AgNO3 and graphite oxide to metallic Ag and reduced graphene oxide, respectively. Due to the highly facilitated electron transport of well distributed Ag nanoparticles, the synthesized ternary nanocomposite showed enhanced photocatalytic activity for degradation of rhodamine B dye under visible light irradiation.
Nagahara, Ryu; Mizutani, Mirai; Matsuo, Akifumi; Kanehisa, Hiroaki; Fukunaga, Tetsuo
2018-06-01
We aimed to investigate the step-to-step spatiotemporal variables and ground reaction forces during the acceleration phase for characterising intra-individual fastest sprinting within a single session. Step-to-step spatiotemporal variables and ground reaction forces produced by 15 male athletes were measured over a 50-m distance during repeated (three to five) 60-m sprints using a long force platform system. Differences in measured variables between the fastest and slowest trials were examined at each step until the 22nd step using a magnitude-based inferences approach. There were possibly-most likely higher running speed and step frequency (2nd to 22nd steps) and shorter support time (all steps) in the fastest trial than in the slowest trial. Moreover, for the fastest trial there were likely-very likely greater mean propulsive force during the initial four steps and possibly-very likely larger mean net anterior-posterior force until the 17th step. The current results demonstrate that better sprinting performance within a single session is probably achieved by 1) a high step frequency (except the initial step) with short support time at all steps, 2) exerting a greater mean propulsive force during initial acceleration, and 3) producing a greater mean net anterior-posterior force during initial and middle acceleration.
Experimental calibration procedures for rotating Lorentz-force flowmeters
Hvasta, M. G.; Slighton, N. T.; Kolemen, E.; ...
2017-07-14
Rotating Lorentz-force flowmeters are a novel and useful technology with a range of applications in a variety of different industries. However, calibrating these flowmeters can be challenging, time-consuming, and expensive. In this paper, simple calibration procedures for rotating Lorentz-force flowmeters are presented. These procedures eliminate the need for expensive equipment, numerical modeling, redundant flowmeters, and system down-time. Finally, the calibration processes are explained in a step-by-step manner and compared to experimental results.
Experimental calibration procedures for rotating Lorentz-force flowmeters
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hvasta, M. G.; Slighton, N. T.; Kolemen, E.
Rotating Lorentz-force flowmeters are a novel and useful technology with a range of applications in a variety of different industries. However, calibrating these flowmeters can be challenging, time-consuming, and expensive. In this paper, simple calibration procedures for rotating Lorentz-force flowmeters are presented. These procedures eliminate the need for expensive equipment, numerical modeling, redundant flowmeters, and system down-time. Finally, the calibration processes are explained in a step-by-step manner and compared to experimental results.
Yuan, Fusong; Lv, Peijun; Wang, Dangxiao; Wang, Lei; Sun, Yuchun; Wang, Yong
2015-02-01
The purpose of this study was to establish a depth-control method in enamel-cavity ablation by optimizing the timing of the focal-plane-normal stepping and the single-step size of a three axis, numerically controlled picosecond laser. Although it has been proposed that picosecond lasers may be used to ablate dental hard tissue, the viability of such a depth-control method in enamel-cavity ablation remains uncertain. Forty-two enamel slices with approximately level surfaces were prepared and subjected to two-dimensional ablation by a picosecond laser. The additive-pulse layer, n, was set to 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 55, 60, 65, 70. A three-dimensional microscope was then used to measure the ablation depth, d, to obtain a quantitative function relating n and d. Six enamel slices were then subjected to three dimensional ablation to produce 10 cavities, respectively, with additive-pulse layer and single-step size set to corresponding values. The difference between the theoretical and measured values was calculated for both the cavity depth and the ablation depth of a single step. These were used to determine minimum-difference values for both the additive-pulse layer (n) and single-step size (d). When the additive-pulse layer and the single-step size were set 5 and 45, respectively, the depth error had a minimum of 2.25 μm, and 450 μm deep enamel cavities were produced. When performing three-dimensional ablating of enamel with a picosecond laser, adjusting the timing of the focal-plane-normal stepping and the single-step size allows for the control of ablation-depth error to the order of micrometers.
Self-Monitoring Procedures: Basic Parameters for Municipal Effluents. Student Reference Manual.
ERIC Educational Resources Information Center
Environmental Protection Agency, Washington, DC. Office of Water Programs.
This is one of several short-term courses developed to assist in the training of waste water treatment plant operational personnel in the tests, measurements, and report preparation required for compliance with their NPDES Permits. The Student Reference Manual provides step-by-step procedures for laboratory application of equipment operating…
ERIC Educational Resources Information Center
McCormick, Cynthia
2012-01-01
For this activity, high school chemistry students compete in a cooking contest. They must determine the chemical and physical changes that occur in the food they prepare, present their recipe as a step-by-step procedure similar to a lab procedure, identify chemicals in the food, and present all measurements in both metric and English units. The…
Numerical modeling and optimization of the Iguassu gas centrifuge
NASA Astrophysics Data System (ADS)
Bogovalov, S. V.; Borman, V. D.; Borisevich, V. D.; Tronin, V. N.; Tronin, I. V.
2017-07-01
The full procedure of the numerical calculation of the optimized parameters of the Iguassu gas centrifuge (GC) is under discussion. The procedure consists of a few steps. On the first step the problem of a hydrodynamical flow of the gas in the rotating rotor of the GC is solved numerically. On the second step the problem of diffusion of the binary mixture of isotopes is solved. The separation power of the gas centrifuge is calculated after that. On the last step the time consuming procedure of optimization of the GC is performed providing us the maximum of the separation power. The optimization is based on the BOBYQA method exploring the results of numerical simulations of the hydrodynamics and diffusion of the mixture of isotopes. Fast convergence of calculations is achieved due to exploring of a direct solver at the solution of the hydrodynamical and diffusion parts of the problem. Optimized separative power and optimal internal parameters of the Iguassu GC with 1 m rotor were calculated using the developed approach. Optimization procedure converges in 45 iterations taking 811 minutes.
ERIC Educational Resources Information Center
Mazerik, Matthew B.
2006-01-01
The mean scores of English Language Learners (ELL) and English Only (EO) students in 4th and 5th grade (N = 110), across the teacher-administered Grammar Skills Test, were examined for differences in participants' scores on assessments containing single-step directions and assessments containing multiple-step directions. The results indicated no…
Estimation of Cadmium uptake by tobacco plants from laboratory leaching tests.
Marković, Jelena P; Jović, Mihajlo D; Smičiklas, Ivana D; Šljivić-Ivanović, Marija Z; Smiljanić, Slavko N; Onjia, Antonije E; Popović, Aleksandar R
2018-03-21
The objective of the present study was to determine the impact of cadmium (Cd) concentration in the soil on its uptake by tobacco plants, and to compare the ability of diverse extraction procedures for determining Cd bioavailability and predicting soil-to-plant transfer and Cd plant concentrations. The pseudo-total digestion procedure, modified Tessier sequential extraction and six standard single-extraction tests for estimation of metal mobility and bioavailability were used for the leaching of Cd from a native soil, as well as samples artificially contaminated over a wide range of Cd concentrations. The results of various leaching tests were compared between each other, as well as with the amounts of Cd taken up by tobacco plants in pot experiments. In the native soil sample, most of the Cd was found in fractions not readily available under natural conditions, but with increasing pollution level, Cd amounts in readily available forms increased. With increasing concentrations of Cd in the soil, the quantity of pollutant taken up in tobacco also increased, while the transfer factor (TF) decreased. Linear and non-linear empirical models were developed for predicting the uptake of Cd by tobacco plants based on the results of selected leaching tests. The non-linear equations for ISO 14870 (diethylenetriaminepentaacetic acid extraction - DTPA), ISO/TS 21268-2 (CaCl 2 leaching procedure), US EPA 1311 (toxicity characteristic leaching procedure - TCLP) single step extractions, and the sum of the first two fractions of the sequential extraction, exhibited the best correlation with the experimentally determined concentrations of Cd in plants over the entire range of pollutant concentrations. This approach can improve and facilitate the assessment of human exposure to Cd by tobacco smoking, but may also have wider applicability in predicting soil-to-plant transfer.
A posteriori model validation for the temporal order of directed functional connectivity maps
Beltz, Adriene M.; Molenaar, Peter C. M.
2015-01-01
A posteriori model validation for the temporal order of neural directed functional connectivity maps is rare. This is striking because models that require sequential independence among residuals are regularly implemented. The aim of the current study was (a) to apply to directed functional connectivity maps of functional magnetic resonance imaging data an a posteriori model validation procedure (i.e., white noise tests of one-step-ahead prediction errors combined with decision criteria for revising the maps based upon Lagrange Multiplier tests), and (b) to demonstrate how the procedure applies to single-subject simulated, single-subject task-related, and multi-subject resting state data. Directed functional connectivity was determined by the unified structural equation model family of approaches in order to map contemporaneous and first order lagged connections among brain regions at the group- and individual-levels while incorporating external input, then white noise tests were run. Findings revealed that the validation procedure successfully detected unmodeled sequential dependencies among residuals and recovered higher order (greater than one) simulated connections, and that the procedure can accommodate task-related input. Findings also revealed that lags greater than one were present in resting state data: With a group-level network that contained only contemporaneous and first order connections, 44% of subjects required second order, individual-level connections in order to obtain maps with white noise residuals. Results have broad methodological relevance (e.g., temporal validation is necessary after directed functional connectivity analyses because the presence of unmodeled higher order sequential dependencies may bias parameter estimates) and substantive implications (e.g., higher order lags may be common in resting state data). PMID:26379489
Modjadidi, Karima; Kovera, Margaret Bull
2018-06-01
We investigated whether watching a videotaped photo array administration or expert testimony could sensitize jurors to the suggestiveness of single-blind eyewitness identification procedures. Mock jurors recruited from the community (N = 231) watched a videotaped simulation of a robbery trial in which the primary evidence against the defendant was an eyewitness identification. We varied whether the witness made an identification from a single- or double-blind photo array, the evidence included a videotape of the photo array procedure, and an expert testified about the effects of single-blind identification procedures on administrators' behaviors and witness accuracy. Watching the videotaped photo array administration sensitized mock jurors to the suggestiveness of the single-blind procedure, causing them to be less likely to convict a defendant identified through single-rather than double-blind procedures. Exposure to the videotaped procedure also decreased the favorability of mock jurors' ratings of the eyewitness, irrespective of whether the lineup was conducted by a single-blind administrator. Expert testimony did not sensitize jurors to administrator bias. Thus, videotaping identification procedures could serve as an important procedural reform that both preserves a record of whether the lineup administration was suggestive and might improve jurors' evaluations of eyewitness evidence. (PsycINFO Database Record (c) 2018 APA, all rights reserved).
Texas two-step: a framework for optimal multi-input single-output deconvolution.
Neelamani, Ramesh; Deffenbaugh, Max; Baraniuk, Richard G
2007-11-01
Multi-input single-output deconvolution (MISO-D) aims to extract a deblurred estimate of a target signal from several blurred and noisy observations. This paper develops a new two step framework--Texas Two-Step--to solve MISO-D problems with known blurs. Texas Two-Step first reduces the MISO-D problem to a related single-input single-output deconvolution (SISO-D) problem by invoking the concept of sufficient statistics (SSs) and then solves the simpler SISO-D problem using an appropriate technique. The two-step framework enables new MISO-D techniques (both optimal and suboptimal) based on the rich suite of existing SISO-D techniques. In fact, the properties of SSs imply that a MISO-D algorithm is mean-squared-error optimal if and only if it can be rearranged to conform to the Texas Two-Step framework. Using this insight, we construct new wavelet- and curvelet-based MISO-D algorithms with asymptotically optimal performance. Simulated and real data experiments verify that the framework is indeed effective.
2013-01-01
Carbon nanotube (CNT) membranes allow the mimicking of natural ion channels for applications in drug delivery and chemical separation. Double-walled carbon nanotube membranes were simply functionalized with dye in a single step instead of the previous two-step functionalization. Non-faradic electrochemical impedance spectra indicated that the functionalized gatekeeper by single-step modification can be actuated to mimic the protein channel under bias. This functional chemistry was proven by a highly efficient ion rectification, wherein the highest experimental rectification factor of ferricyanide was up to 14.4. One-step functionalization by electrooxidation of amine provides a simple and promising functionalization chemistry for the application of CNT membranes. PMID:23758999
21 CFR 1270.31 - Written procedures.
Code of Federal Regulations, 2011 CFR
2011-04-01
... procedures prepared and followed for all significant steps in the infectious disease testing process under... procedures prepared, validated, and followed for prevention of infectious disease contamination or cross...
21 CFR 1270.31 - Written procedures.
Code of Federal Regulations, 2012 CFR
2012-04-01
... procedures prepared and followed for all significant steps in the infectious disease testing process under... procedures prepared, validated, and followed for prevention of infectious disease contamination or cross...
21 CFR 1270.31 - Written procedures.
Code of Federal Regulations, 2014 CFR
2014-04-01
... procedures prepared and followed for all significant steps in the infectious disease testing process under... procedures prepared, validated, and followed for prevention of infectious disease contamination or cross...
21 CFR 1270.31 - Written procedures.
Code of Federal Regulations, 2013 CFR
2013-04-01
... procedures prepared and followed for all significant steps in the infectious disease testing process under... procedures prepared, validated, and followed for prevention of infectious disease contamination or cross...
Development of a high frequency single-element ultrasound needle transducer for anesthesia delivery
NASA Astrophysics Data System (ADS)
Ameri, Golafsoun; Son, Jungik; Liang, Jingwei; Foster, F. Stuart; Ganapathy, Sugantha; Peters, Terry M.
2017-03-01
Epidural anesthesia is one of the most commonly used and yet challenging techniques employed for pain management and anesthesia delivery. The major complications of this procedure are due to accidental dural puncture, with an incidence of 1-3%, which could lead to both temporary and irreversible permanent neurological complications. Needle placement under ultrasound (US) guidance has received increasing interest for improving needle placement accuracy. However, poor needle visibility in US, difficulties in displaying relevant anatomical structure such as dura mater due to attenuation and bone shadowing, and image interpretation variability among users pose significant hurdles for any US guidance system. As a result, US guidance for epidural injections has not been widely adopted for everyday use for the performance of neuraxial blocks. The difficulties in localizing the ligamentum flavum and dura with respect to the needle tip can be addressed by integrating A-mode US, provided by a single-element transducer at the needle tip, into the B-mode US guidance system. We have taken the first steps towards providing such a guidance system. Our goal is to improve the safety of this procedure with minimal changes to the clinical workflow. This work presents the design and development of a 20 MHz single-element US transducer housed at the tip of a 19 G needle hypodermic tube, which can fit inside an epidural introducer needle. In addition, the results from initial transducer characterization tests and performance evaluation of the transducer in a euthanized porcine model are provided.
SERE: single-parameter quality control and sample comparison for RNA-Seq.
Schulze, Stefan K; Kanwar, Rahul; Gölzenleuchter, Meike; Therneau, Terry M; Beutler, Andreas S
2012-10-03
Assessing the reliability of experimental replicates (or global alterations corresponding to different experimental conditions) is a critical step in analyzing RNA-Seq data. Pearson's correlation coefficient r has been widely used in the RNA-Seq field even though its statistical characteristics may be poorly suited to the task. Here we present a single-parameter test procedure for count data, the Simple Error Ratio Estimate (SERE), that can determine whether two RNA-Seq libraries are faithful replicates or globally different. Benchmarking shows that the interpretation of SERE is unambiguous regardless of the total read count or the range of expression differences among bins (exons or genes), a score of 1 indicating faithful replication (i.e., samples are affected only by Poisson variation of individual counts), a score of 0 indicating data duplication, and scores >1 corresponding to true global differences between RNA-Seq libraries. On the contrary the interpretation of Pearson's r is generally ambiguous and highly dependent on sequencing depth and the range of expression levels inherent to the sample (difference between lowest and highest bin count). Cohen's simple Kappa results are also ambiguous and are highly dependent on the choice of bins. For quantifying global sample differences SERE performs similarly to a measure based on the negative binomial distribution yet is simpler to compute. SERE can therefore serve as a straightforward and reliable statistical procedure for the global assessment of pairs or large groups of RNA-Seq datasets by a single statistical parameter.
SERE: Single-parameter quality control and sample comparison for RNA-Seq
2012-01-01
Background Assessing the reliability of experimental replicates (or global alterations corresponding to different experimental conditions) is a critical step in analyzing RNA-Seq data. Pearson’s correlation coefficient r has been widely used in the RNA-Seq field even though its statistical characteristics may be poorly suited to the task. Results Here we present a single-parameter test procedure for count data, the Simple Error Ratio Estimate (SERE), that can determine whether two RNA-Seq libraries are faithful replicates or globally different. Benchmarking shows that the interpretation of SERE is unambiguous regardless of the total read count or the range of expression differences among bins (exons or genes), a score of 1 indicating faithful replication (i.e., samples are affected only by Poisson variation of individual counts), a score of 0 indicating data duplication, and scores >1 corresponding to true global differences between RNA-Seq libraries. On the contrary the interpretation of Pearson’s r is generally ambiguous and highly dependent on sequencing depth and the range of expression levels inherent to the sample (difference between lowest and highest bin count). Cohen’s simple Kappa results are also ambiguous and are highly dependent on the choice of bins. For quantifying global sample differences SERE performs similarly to a measure based on the negative binomial distribution yet is simpler to compute. Conclusions SERE can therefore serve as a straightforward and reliable statistical procedure for the global assessment of pairs or large groups of RNA-Seq datasets by a single statistical parameter. PMID:23033915
Using an Automated 3D-tracking System to Record Individual and Shoals of Adult Zebrafish
Maaswinkel, Hans; Zhu, Liqun; Weng, Wei
2013-01-01
Like many aquatic animals, zebrafish (Danio rerio) moves in a 3D space. It is thus preferable to use a 3D recording system to study its behavior. The presented automatic video tracking system accomplishes this by using a mirror system and a calibration procedure that corrects for the considerable error introduced by the transition of light from water to air. With this system it is possible to record both single and groups of adult zebrafish. Before use, the system has to be calibrated. The system consists of three modules: Recording, Path Reconstruction, and Data Processing. The step-by-step protocols for calibration and using the three modules are presented. Depending on the experimental setup, the system can be used for testing neophobia, white aversion, social cohesion, motor impairments, novel object exploration etc. It is especially promising as a first-step tool to study the effects of drugs or mutations on basic behavioral patterns. The system provides information about vertical and horizontal distribution of the zebrafish, about the xyz-components of kinematic parameters (such as locomotion, velocity, acceleration, and turning angle) and it provides the data necessary to calculate parameters for social cohesions when testing shoals. PMID:24336189
NASA Astrophysics Data System (ADS)
Bagán, H.; Tarancón, A.; Rauret, G.; García, J. F.
2008-07-01
The quenching parameters used to model detection efficiency variations in scintillation measurements have not evolved since the decade of 1970s. Meanwhile, computer capabilities have increased enormously and ionization quenching has appeared in practical measurements using plastic scintillation. This study compares the results obtained in activity quantification by plastic scintillation of 14C samples that contain colour and ionization quenchers, using classical (SIS, SCR-limited, SCR-non-limited, SIS(ext), SQP(E)) and evolved (MWA-SCR and WDW) parameters and following three calibration approaches: single step, which does not take into account the quenching mechanism; two steps, which takes into account the quenching phenomena; and multivariate calibration. Two-step calibration (ionization followed by colour) yielded the lowest relative errors, which means that each quenching phenomenon must be specifically modelled. In addition, the sample activity was quantified more accurately when the evolved parameters were used. Multivariate calibration-PLS also yielded better results than those obtained using classical parameters, which confirms that the quenching phenomena must be taken into account. The detection limits for each calibration method and each parameter were close to those obtained theoretically using the Currie approach.
A Method for Developing Standard Patient Education Program.
Lura, Carolina Bryne; Hauch, Sophie Misser Pallesgaard; Gøeg, Kirstine Rosenbeck; Pape-Haugaard, Louise
2018-01-01
In Denmark, patients being treated on Haematology Outpatients Departments get instructed to self-manage their blood sample collection from Central Venous Catheter (CVC). However, this is a complex and risky procedure, which can jeopardize patient safety. The aim of the study was to suggest a method for developing standard digital patient education programs for patients in self-administration of blood samples drawn from CVC. The Design Science Research Paradigm was used to develop a digital patient education program, called PAVIOSY, to increase patient safety during execution of the blood sample collection procedure by using videos for teaching as well as procedural support. A step-by-step guide was developed and used as basis for making the videos. Quality assurance through evaluation with a nurse was conducted on both the step-by-step guide and the videos. The quality assurance evaluation of the videos showed; 1) Errors due to the order of the procedure can be determined by reviewing the videos despite that the guide was followed. 2) Videos can be used to identify errors - important for patient safety - in the procedure, which are not identifiable in a written script. To ensure correct clinical content of the educational patient system, health professionals must be engaged early in the development of content and design phase.
Lee, Dong Ha; Sun, Kyung Chul; Qadir, Muhammad Bilal; Jeong, Sung Hoon
2014-12-01
Dye-sensitized solar cell (DSSC) is an attractive renewable energy technology currently under intense investigation. Electrolyte plays an important role in the photovoltaic performance of the DSSCs and many efforts have been contributed to study different kinds of electrolytes with various characteristics such as liquid electrolytes, polymer electrolytes and so on. In this study, DSSC is developed by using quasi-solid electrolyte and a novel procedure is adopted for filling this electrolyte. The quasi-solid-state electrolyte was prepared by mixing Poly ethylene oxide (PEO) and bismaleimide together and constitution was taken as PEO (15 wt%) at various bismaleimide concentrations (1, 3, 5 wt%). The novel procedure of filling electrolyte consists of three major steps (first step: filling liquid electrolyte, second step: vaporization of liquid electrolyte, third step: refilling quasi-solid-state electrolyte). The electrochemical and photovoltaic performances of DSSCs with these electrolytes were also investigated. The electrochemical impedance spectroscopy (EIS) indicated that TiO2/Dye/electrolyte impedance is reduced and electron lifetime is increased, and consequently efficiency of cell has been improved after using this novel procedure. The photovoltaic power conversion efficiency of 6.39% has been achieved under AM 1.5 simulated sunlight (100 W/cm2) through this novel procedure and by using specified blend of polymers.
Characteristics of camel-gate structures with active doping channel profiles
NASA Astrophysics Data System (ADS)
Tsai, Jung-Hui; Lour, Wen-Shiung; Laih, Lih-Wen; Liu, Rong-Chau; Liu, Wen-Chau
1996-03-01
In this paper, we demonstrate the influence of channel doping profile on the performances of camel-gate field effect transistors (CAMFETs). For comparison, single and tri-step doping channel structures with identical doping thickness products are employed, while other parameters are kept unchanged. The results of a theoretical analysis show that the single doping channel FET with lightly doping active layer has higher barrier height and drain-source saturation current. However, the transconductance is decreased. For a tri-step doping channel structure, it is found that the output drain-source saturation current and the barrier height are enhanced. Furthermore, the relatively voltage independent performances are improved. Two CAMFETs with single and tri-step doping channel structures have been fabricated and discussed. The devices exhibit nearly voltage independent transconductances of 144 mS mm -1 and 222 mS mm -1 for single and tri-step doping channel CAMFETs, respectively. The operation gate voltage may extend to ± 1.5 V for a tri-step doping channel CAMFET. In addition, the drain current densities of > 750 and 405 mA mm -1 are obtained for the tri-step and single doping CAMFETs. These experimental results are inconsistent with theoretical analysis.
Matsunaga, Hiroko; Goto, Mari; Arikawa, Koji; Shirai, Masataka; Tsunoda, Hiroyuki; Huang, Huan; Kambara, Hideki
2015-02-15
Analyses of gene expressions in single cells are important for understanding detailed biological phenomena. Here, a highly sensitive and accurate method by sequencing (called "bead-seq") to obtain a whole gene expression profile for a single cell is proposed. A key feature of the method is to use a complementary DNA (cDNA) library on magnetic beads, which enables adding washing steps to remove residual reagents in a sample preparation process. By adding the washing steps, the next steps can be carried out under the optimal conditions without losing cDNAs. Error sources were carefully evaluated to conclude that the first several steps were the key steps. It is demonstrated that bead-seq is superior to the conventional methods for single-cell gene expression analyses in terms of reproducibility, quantitative accuracy, and biases caused during sample preparation and sequencing processes. Copyright © 2014 Elsevier Inc. All rights reserved.
Zemberyová, Mária; Barteková, Jana; Hagarová, Ingrid
2006-12-15
A modified three-step sequential extraction procedure for the fractionation of heavy metals, proposed by the Commission of the European Communities Bureau of Reference (BCR) has been applied to the Slovak reference materials of soils (soil orthic luvisols, soil rendzina and soil eutric cambisol), which represent pedologically different types of soils in Slovakia. Analyses were carried out by flame or electrothermal atomic absorption spectrometry (FAAS or ETAAS). The fractions extracted were: exchangeable (extraction step 1), reducible-iron/manganese oxides (extraction step 2), oxidizable-organic matter and sulfides (extraction step 3). The sum of the element contents in the three fractions plus aqua-regia extractable content of the residue was compared to the aqua-regia extractable content of the elements in the origin soils. The accuracy obtained by comparing the determined contents of the elements with certified values, using BCR CRM 701, certified for the extractable contents (mass fractions) of Cd, Cr, Cu, Ni, Pb and Zn in sediment following a modified BCR-three step sequential extraction procedure, was found to be satisfactory.
Accuracy of meteoroid speeds determined using a Fresnel transform procedure
NASA Astrophysics Data System (ADS)
Campbell, L.; Elford, W. G.
2006-03-01
New methods of determining meteor speeds using radar are giving results with an accuracy of better that 1%. It is anticipated that this degree of precision will allow determinations of pre-atmospheric speeds of shower meteors as well as estimates of the density of the meteoroids. The next step is to determine under what conditions these new measurements are reliable. Errors in meteoroid speeds determined using a Fresnel transform procedure applied to radar meteor data are investigated. The procedure determines the reflectivity of a meteor trail as a function of position, by application of the Fresnel transform to the time series of a radar reflection from the trail observed at a single detection station. It has previously been shown that this procedure can be used to determine the speed of the meteoroid, by finding the assumed speed that gives a reflectivity image that best meets physical expectations. It has also been shown that speeds determined by this method agree with those from the well established "pre-t o phase" method when applied to reflections with a high signal to noise ratio. However, there is a discrepancy between the two methods for weaker reflections. A method to investigate the discrepancy is described and applied, with the finding that the speed determined by using the Fresnel transform procedure is more accurate for weaker reflections than that given by the "pre-t o phase" method.
Becker, G
2001-01-01
The accreditation of the ISO 9001 certification (ISO = International Standard Organization) is an external evaluation procedure carried out by independent experts, whose object is the analysis of the operational methods and practices of a medical care facility (e.g. hospital, private clinic, general practitioner's or dentist's practice) which decided to assume the concept, implementation and control of its own quality policy. The whole accreditation procedure represents the basic structure of a continuous dynamic progressiveness within a cabinet eager to offer outstanding quality. Moreover, it guarantees active and voluntary participation of every single member of the medical administration or technical team involved in the realization of this primary objective. In other words, we are talking about a very strong dynamic innovation leading to a change of views and the improvement of communication means, while simultaneously enhancing the security and quality aspects of medical care. The continuous guarantee of high quality medical care calls for precise planning and systematization of actions. First of all, these actions are defined, analyzed and listed in precise work procedures. As they are defined with the agreement of the whole team, they implicate respect and self control. This requires of course transparency of the treatment methods, whose different steps and procedures are described in detail in a logogramm set up in common.
Gerstner, Arpad; DeFord, James H; Papaconstantinou, John
2003-07-25
Ames dwarfism is caused by a homozygous single nucleotide mutation in the pituitary specific prop-1 gene, resulting in combined pituitary hormone deficiency, reduced growth and extended lifespan. Thus, these mice serve as an important model system for endocrinological, aging and longevity studies. Because the phenotype of wild type and heterozygous mice is undistinguishable, it is imperative for successful breeding to accurately genotype these animals. Here we report a novel, yet simple, approach for prop-1 genotyping using PCR-based allele-specific amplification (PCR-ASA). We also compare this method to other potential genotyping techniques, i.e. PCR-based restriction fragment length polymorphism analysis (PCR-RFLP) and fluorescence automated DNA sequencing. We demonstrate that the single-step PCR-ASA has several advantages over the classical PCR-RFLP because the procedure is simple, less expensive and rapid. To further increase the specificity and sensitivity of the PCR-ASA, we introduced a single-base mismatch at the 3' penultimate position of the mutant primer. Our results also reveal that the fluorescence automated DNA sequencing has limitations for detecting a single nucleotide polymorphism in the prop-1 gene, particularly in heterozygotes.
Attachment of micro- and nano-particles on tipless cantilevers for colloidal probe microscopy.
D'Sa, Dexter J; Chan, Hak-Kim; Chrzanowski, Wojciech
2014-07-15
Current colloidal probe preparation techniques face several challenges in the production of functional probes using particles ⩽5 μm. Challenges include: glue encapsulated particles, glue altered particle properties, improper particle or agglomerate attachment, and lengthy procedures. We present a method to rapidly and reproducibly produce functional micro and nano-colloidal probes. Using a six-step procedure, cantilevers mounted on a custom designed 45° holder were used to approach and obtain a minimal amount of epoxy resin (viscosity of ∼14,000 cP) followed by a single micron/nano particle on the apex of a tipless cantilever. The epoxy and particles were prepared on individual glass slides and subsequently affixed to a 10× or 40× optical microscope lens using another custom designed holder. Scanning electron microscopy and comparative glue-colloidal probe measurements were used to confirm colloidal probe functionality. The method presented allowed rapid and reproducible production of functional colloidal probes (80% success). Single nano-particles were prominently affixed to the apex of the cantilever, unaffected by the epoxy. Nano-colloidal probes were used to conduct topographical, instantaneous force, and adhesive force mapping measurements in dry and liquid media conveying their versatility and functionality in studying nano-colloidal systems. Copyright © 2014 Elsevier Inc. All rights reserved.
Picardi, Ernesto; Gallo, Angela; Galeano, Federica; Tomaselli, Sara; Pesole, Graziano
2012-01-01
RNA editing is a post-transcriptional process occurring in a wide range of organisms. In human brain, the A-to-I RNA editing, in which individual adenosine (A) bases in pre-mRNA are modified to yield inosine (I), is the most frequent event. Modulating gene expression, RNA editing is essential for cellular homeostasis. Indeed, its deregulation has been linked to several neurological and neurodegenerative diseases. To date, many RNA editing sites have been identified by next generation sequencing technologies employing massive transcriptome sequencing together with whole genome or exome sequencing. While genome and transcriptome reads are not always available for single individuals, RNA-Seq data are widespread through public databases and represent a relevant source of yet unexplored RNA editing sites. In this context, we propose a simple computational strategy to identify genomic positions enriched in novel hypothetical RNA editing events by means of a new two-steps mapping procedure requiring only RNA-Seq data and no a priori knowledge of RNA editing characteristics and genomic reads. We assessed the suitability of our procedure by confirming A-to-I candidates using conventional Sanger sequencing and performing RNA-Seq as well as whole exome sequencing of human spinal cord tissue from a single individual. PMID:22957051
Krishnan, Anuradha; Viviano, Jeffrey; Morozov, Yaroslav; Venkataraman, Venkat
2016-07-01
Hippocalcin is a 193 aa protein that is a member of the neuronal calcium sensor protein family, whose functions are regulated by calcium. Mice that lack the function of this protein are compromised in the long term potentiation aspect of memory generation. Recently, mutations in the gene have been linked with dystonia in human. The protein has no intrinsic enzyme activity but is known to bind to variety of target proteins. Very little information is available on how the protein executes its critical role in signaling pathways, except that it is regulated by binding of calcium. Further delineation of its function requires large amounts of pure protein. In this report, we present a single-step purification procedure that yields high quantities of the bacterially expressed, recombinant protein. The procedure may be adapted to purify the protein from inclusion bodies or cytosol in its myristoylated or non-myristoylated forms. MALDI-MS (in source decay) analyses demonstrates that the myristoylation occurs at the glycine residue. The protein is also biologically active as measured through tryptophan fluorescence, mobility shift and guanylate cyclase activity assays. Thus, further analyses of hippocalcin, both structural and functional, need no longer be limited by protein availability. Copyright © 2016 Elsevier Inc. All rights reserved.
48 CFR 6.102 - Use of competitive procedures.
Code of Federal Regulations, 2011 CFR
2011-10-01
... ACQUISITION PLANNING COMPETITION REQUIREMENTS Full and Open Competition 6.102 Use of competitive procedures. The competitive procedures available for use in fulfilling the requirement for full and open... procedures (e.g., two-step sealed bidding). (d) Other competitive procedures. (1) Selection of sources for...
Adaptive [theta]-methods for pricing American options
NASA Astrophysics Data System (ADS)
Khaliq, Abdul Q. M.; Voss, David A.; Kazmi, Kamran
2008-12-01
We develop adaptive [theta]-methods for solving the Black-Scholes PDE for American options. By adding a small, continuous term, the Black-Scholes PDE becomes an advection-diffusion-reaction equation on a fixed spatial domain. Standard implementation of [theta]-methods would require a Newton-type iterative procedure at each time step thereby increasing the computational complexity of the methods. Our linearly implicit approach avoids such complications. We establish a general framework under which [theta]-methods satisfy a discrete version of the positivity constraint characteristic of American options, and numerically demonstrate the sensitivity of the constraint. The positivity results are established for the single-asset and independent two-asset models. In addition, we have incorporated and analyzed an adaptive time-step control strategy to increase the computational efficiency. Numerical experiments are presented for one- and two-asset American options, using adaptive exponential splitting for two-asset problems. The approach is compared with an iterative solution of the two-asset problem in terms of computational efficiency.
von der Heide, Anna Maria; Fallavollita, Pascal; Wang, Lejing; Sandner, Philipp; Navab, Nassir; Weidert, Simon; Euler, Ekkehard
2018-04-01
In orthopaedic trauma surgery, image-guided procedures are mostly based on fluoroscopy. The reduction of radiation exposure is an important goal. The purpose of this work was to investigate the impact of a camera-augmented mobile C-arm (CamC) on radiation exposure and the surgical workflow during a first clinical trial. Applying a workflow-oriented approach, 10 general workflow steps were defined to compare the CamC to traditional C-arms. The surgeries included were arbitrarily identified and assigned to the study. The evaluation criteria were radiation exposure and operation time for each workflow step and the entire surgery. The evaluation protocol was designed and conducted in a single-centre study. The radiation exposure was remarkably reduced by 18 X-ray shots 46% using the CamC while keeping similar surgery times. The intuitiveness of the system, its easy integration into the surgical workflow, and its great potential to reduce radiation have been demonstrated. Copyright © 2017 John Wiley & Sons, Ltd.
Fire Safety Trianing in Health Care Institutions.
ERIC Educational Resources Information Center
American Hospital Association, Chicago, IL.
The manual details the procedures to be followed in developing and implementing a fire safety plan. The three main steps are first, to organize; second, to set up a procedure and put it in writing; and third, to train and drill employees and staff. Step 1 involves organizing a safety committee, appointing a fire marshall, and seeking help from…
Film Editing Handbook; Technique of 16mm Film Cutting.
ERIC Educational Resources Information Center
Churchill, Hugh B.
Designed to help the film student with the complexities of 16mm film cutting, this handbook catalogs the mechanical procedures of both picture and sound cutting and supplies step-by-step explanations of these procedures. Because the handbook was organized so that it could be used while working at the cutting bench, common cutting problems and…
Project visual analysis for the Allegheny National Forest
Gary W. Kell
1979-01-01
The Project Visual Analysis is a landscape assessment procedure involving forest vegetative manipulation. A logical step by step analysis leads the user to a specific set of landscape management guidelines to be used as an aid in designing a project or in evaluating whether the proposed project impacts will meet visual objectives. Key elements within the procedure are...
Composting. Sludge Treatment and Disposal Course #166. Instructor's Guide [and] Student Workbook.
ERIC Educational Resources Information Center
Arasmith, E. E.
Composting is a lesson developed for a sludge treatment and disposal course. The lesson discusses the basic theory of composting and the basic operation, in a step-by-step sequence, of the two typical composting procedures: windrow and forced air static pile. The lesson then covers basic monitoring and operational procedures. The instructor's…
Step by Step: Biology Undergraduates' Problem-Solving Procedures during Multiple-Choice Assessment
ERIC Educational Resources Information Center
Prevost, Luanna B.; Lemons, Paula P.
2016-01-01
This study uses the theoretical framework of domain-specific problem solving to explore the procedures students use to solve multiple-choice problems about biology concepts. We designed several multiple-choice problems and administered them on four exams. We trained students to produce written descriptions of how they solved the problem, and this…
Castle, Maria; Rivero, Mónica; Marquez, Javier
2013-02-01
The current standard treatment of Ewing's sarcoma is chemotherapy followed by surgery, making an immediate cranial reconstruction in a one-step surgical procedure possible. We describe the technique used to repair a cranial defect after the resection of a primary Ewing's sarcoma of the skull in a one-step surgical procedure. Bone repair with a custom-made cranioplasty immediately after resection of a primary Ewing's sarcoma of the skull avoids deformities and late complications associated with reconstructive surgery after radiotherapy and not interfere with radiotherapy and neither with follow-up. A one-step surgical procedure after chemotherapy for primary Ewing's sarcoma of the skull could be safer, less aggressive and more radical; avoiding deformities and late complications.
Ting, Daniel Shu Wei; Tan, Sarah; Lee, Shu Yen; Rosman, Mohamad; Aw, Ai Tee; Yeo, Ian Yew San
2015-07-01
To investigate residents' self-reported satisfaction level with their proficiency in extracapsular cataract extraction (ECCE) surgery and the initial barriers to learning the procedure. This is a single-centre prospective descriptive case series involving eight first-year ophthalmology residents in Singapore National Eye Center. We recorded the demographics, frequency of review by the residents of their own surgical videos and their satisfaction level with their proficiency at each of the ECCE steps using a 5-point Likert scale. All ECCE surgical videos between October 2013 and May 2014 were collected and analysed for the overall time taken for the surgery and the time taken to perform the individual steps of the procedure. The mean age of the residents was 27.6 ± 1.5 years and 62.5% (5/8) were women. More than half (62.5%, 5/8) reviewed their own surgical videos while 37.5% (3/8) discussed the surgical videos with their peers or supervisors. Of the ECCE steps, the residents were most dissatisfied with their proficiency in performing irrigation and aspiration (87.5%, 7/8), followed by suturing (62.5%, 5/8), intraocular lens insertion (62.5%, 5/8) and tin can capsulotomy (62.5%, 5/8). The average time taken for each ECCE case was 55.0 ± 12.2 min and, of all the steps, most time was spent on suturing (20.5 ± 6.8 min), followed by irrigation and aspiration (5.5 ± 3.6 min) and tin can capsulotomy (3.3 ± 1.8 min). The first-year ophthalmology residents were most dissatisfied with their proficiency in irrigation/aspiration, suturing and tin can capsulotomy. More training needs to be directed to these areas during teaching sessions in the operating room, wet laboratory or cataract simulation training sessions. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Saraiva, Letícia O; Aguiar, Thaiane R; Costa, Leonardo; Cavalcanti, Andrea N; Giannini, Marcelo; Mathias, Paula
2015-01-01
The effect of the intraoral environment during adhesive restorative procedures remains a concern, especially in the absence of rubber dam isolation. To evaluate the temperature and relative humidity (RH) at anterior and posterior intraoral sites and their effects on the dentin bond strength of two-step etch-and-rinse adhesive systems. Sixty human molars were assigned to six groups according to the adhesive systems (Adper Single Bond Plus and One Step Plus) and intraoral sites (incisor and molar sites). The room condition was used as a control group. Dentin fragments were individually placed in custom-made acetate trays and direct composite restorations were performed. The intraoral temperature and RH were recorded during adhesive procedures. Then, specimens were removed from the acetate trays and sectioned to obtain multiple beams for the microtensile bond strength test. In addition, the adhesive interface morphology was evaluated through scanning electron microscopy. Intraoral conditions were statistically analyzed by paired Students' t-tests and the bond strength data by two-way analysis of variance and Tukey test (α = 0.05). The posterior intraoral site showed a significant increase in the temperature and RH when compared with the anterior site. However, both intraoral sites revealed higher temperatures and RH than the room condition. In regards to the adhesive systems, the intraoral environment did not affect the bond strength, and the One Step Plus system showed the highest bond strength means. Despite the fact that remarkable changes in the intraoral conditions were observed for both anterior and posterior sites, the intraoral environment was not able to compromise the immediate dentin bond strength. Some conditions of intraoral temperature and relative humidity may not impair the dentin bond strength of two-step etch-and-rinse adhesive systems. Thus, an adequate relative isolation seems to be a good alternative under the specific clinical conditions in which rubber dam isolation is either impossible or very difficult to perform. © 2014 Wiley Periodicals, Inc.
[Bilateral labio-maxillo-palatal clefts. Therapeutic evaluation].
Raphaël, B; Morand, B; Bettega, G; Lesne, V; Lesne, C; Lebeau, J
2001-06-01
The wide diversity of bilateral facial clefts makes it most difficult to assess surgical success, particularly in terms of long-term outcome. The aim of this work was to examine the rationale for the current protocol used for cleft surgery at the Grenoble University Hospital. In a first group of 28 children, a 3-step surgical protocol was applied. The first two steps were performed between 4 and 8 months with at least 3 months between each procedure. Skoog's unilateral cheilo-rhino-uranoplasty was used, associated with a periosteal tibial graft. The third step, performed between 10 and 12 months, was for staphylorraphy. Outcome was analyzed at 15 years and evidenced the deleterious effect of excessive and asymmetrical premaxillary scars, of the 2-step cheiloplasty and of columella lengthenings from the lip. The frequency of secondary revision of the superior labial vestibule and the medial labial tubercule (43%) was considered to be high; this procedure should be re-examined as should be osteotomy (32% revision). Palatine closure, acquired in 82% of the cases and premaxillary stability, achieved in 86%, would appear to favor use of the periosteal tibial graft. The osteogenic capacity of this graft tissue was less satisfactory after a second harvesting (from the same tibia three months later). These results have led us to modify our protocol, favoring early and total closure of the bony palate and continued use of the periosteal tibial graft. We now use the following operative protocol: premaxillary alignment using an active orthopedic plate at 2 months, lip adhesion associated with staphylorraphy and passive palatine contention plate at 3 months, definitive bilateral cheilo-uranoplasty associated with a single periosteal graft at 7 months. The preliminary results with this protocol in a group of 12 children have shown better quality scars, more harmonious maxillary arches, an excellent occlusion of the deciduous dentition, and preservation of the positive results obtained with the periosteal tibial graft.
Liao, Ching-Hsing; Fett, William F
2003-05-15
Three major foodborne outbreaks of salmonellosis in 1998 and 1999 were linked to the consumption of raw alfalfa sprouts. In this report, an improved method is described for isolation of Salmonella from alfalfa seed lots, which had been implicated in these outbreaks. From each seed lot, eight samples each containing 25 g of seed were tested for the presence of Salmonella by the US FDA Bacteriological Analytical Manual (BAM) procedure and by a modified method applying two successive pre-enrichment steps. Depending on the seed lot, one to four out of eight samples tested positive for Salmonella by the standard procedure and two to seven out of eight samples tested positive by the modified method. Thus, the use of two consecutive pre-enrichment steps led to a higher detection rate than a single pre-enrichment step. This result indirectly suggested that Salmonella cells on contaminated seeds might be injured and failed to fully resuscitate in pre-enrichment broth containing seed components during the first 24 h of incubation. Responses of heat-injured Salmonella cells grown in buffered peptone water (BPW) and in three alfalfa seed homogenates were investigated. For preparation of seed homogenates, 25 g of seeds were homogenized in 200 ml of BPW using a laboratory Stomacher and subsequently held at 37 degrees C for 24 h prior to centrifugation and filtration. While untreated cells grew at about the same rate in BPW and in seed homogenates, heat-injured cells (52 degrees C, 10 min) required approximately 0.5 to 4.0 h longer to resuscitate in seed homogenates than in BPW. This result suggests that the alfalfa seed components or fermented metabolites from native bacteria hinder the repair and growth of heat-injured cells. This study also shows that an additional pre-enrichment step increases the frequency of isolation of Salmonella from naturally contaminated seeds, possibly by alleviating the toxic effect of seed homogenates on repair or growth of injured cells.
ERIC Educational Resources Information Center
Herman, Susan
1995-01-01
Aerobics instructors can use step aerobics to motivate students. One creative method is to add the step to the circuit workout. By incorporating the step, aerobic instructors can accommodate various fitness levels. The article explains necessary equipment and procedures, describing sample stations for cardiorespiratory fitness, muscular strength,…
Soares, Marcelo Bento; Bonaldo, Maria de Fatima
1998-01-01
This invention provides a method to normalize a cDNA library comprising: (a) constructing a directionally cloned library containing cDNA inserts wherein the insert is capable of being amplified by polymerase chain reaction; (b) converting a double-stranded cDNA library into single-stranded DNA circles; (c) generating single-stranded nucleic acid molecules complementary to the single-stranded DNA circles converted in step (b) by polymerase chain reaction with appropriate primers; (d) hybridizing the single-stranded DNA circles converted in step (b) with the complementary single-stranded nucleic acid molecules generated in step (c) to produce partial duplexes to an appropriate Cot; and (e) separating the unhybridized single-stranded DNA circles from the hybridized DNA circles, thereby generating a normalized cDNA library. This invention also provides a method to normalize a cDNA library wherein the generating of single-stranded nucleic acid molecules complementary to the single-stranded DNA circles converted in step (b) is by excising cDNA inserts from the double-stranded cDNA library; purifying the cDNA inserts from cloning vectors; and digesting the cDNA inserts with an exonuclease. This invention further provides a method to construct a subtractive cDNA library following the steps described above. This invention further provides normalized and/or subtractive cDNA libraries generated by the above methods.
Soares, M.B.; Fatima Bonaldo, M. de
1998-12-08
This invention provides a method to normalize a cDNA library comprising: (a) constructing a directionally cloned library containing cDNA inserts wherein the insert is capable of being amplified by polymerase chain reaction; (b) converting a double-stranded cDNA library into single-stranded DNA circles; (c) generating single-stranded nucleic acid molecules complementary to the single-stranded DNA circles converted in step (b) by polymerase chain reaction with appropriate primers; (d) hybridizing the single-stranded DNA circles converted in step (b) with the complementary single-stranded nucleic acid molecules generated in step (c) to produce partial duplexes to an appropriate Cot; and (e) separating the unhybridized single-stranded DNA circles from the hybridized DNA circles, thereby generating a normalized cDNA library. This invention also provides a method to normalize a cDNA library wherein the generating of single-stranded nucleic acid molecules complementary to the single-stranded DNA circles converted in step (b) is by excising cDNA inserts from the double-stranded cDNA library; purifying the cDNA inserts from cloning vectors; and digesting the cDNA inserts with an exonuclease. This invention further provides a method to construct a subtractive cDNA library following the steps described above. This invention further provides normalized and/or subtractive cDNA libraries generated by the above methods. 25 figs.
Zhao, Wenle; Pauls, Keith
2015-01-01
Background Centralized outcome adjudication has been used widely in multi-center clinical trials in order to prevent potential biases and to reduce variations in important safety and efficacy outcome assessments. Adjudication procedures could vary significantly among different studies. In practice, the coordination of outcome adjudication procedures in many multicenter clinical trials remains as a manual process with low efficiency and high risk of delay. Motivated by the demands from two large clinical trial networks, a generic outcome adjudication module has been developed by the network’s data management center within a homegrown clinical trial management system. In this paper, the system design strategy and database structure are presented. Methods A generic database model was created to transfer different adjudication procedures into a unified set of sequential adjudication steps. Each adjudication step was defined by one activate condition, one lock condition, one to five categorical data items to capture adjudication results, and one free text field for general comments. Based on this model, a generic outcome adjudication user interface and a generic data processing program were developed within a homegrown clinical trial management system to provide automated coordination of outcome adjudication. Results By the end of 2014, this generic outcome adjudication module had been implemented in 10 multicenter trials. A total of 29 adjudication procedures were defined with the number of adjudication steps varying from 1 to 7. The implementation of a new adjudication procedure in this generic module took an experienced programmer one or two days. A total of 7,336 outcome events had been adjudicated and 16,235 adjudication step activities had been recorded. In a multicenter trial, 1144 safety outcome event submissions went through a three-step adjudication procedure and reported a median of 3.95 days from safety event case report form submission to adjudication completion. In another trial, 277 clinical outcome events were adjudicated by a six-step procedure and took a median of 23.84 days from outcome event case report form submission to adjudication procedure completion. Conclusions A generic outcome adjudication module integrated in the clinical trial management system made the automated coordination of efficacy and safety outcome adjudication a reality. PMID:26464429
Kimura, Yuka; Ishibashi, Yasuyuki; Tsuda, Eiichi; Yamamoto, Yuji; Hayashi, Yoshimitsu; Sato, Shuichi
2012-03-01
In badminton, knees opposite to the racket-hand side received anterior cruciate ligament (ACL) injuries during single-leg landing after overhead stroke. Most of them occurred in the backhand-side of the rear court. Comparing lower limb biomechanics during single-leg landing after overhead stroke between the forehand-side and backhand-side court may help explain the different injury rates depending on court position. The knee kinematics and kinetics during single-leg landing after overhead stroke following back-stepping were different between the forehand-side and backhand-side court. Controlled laboratory study. Hip, knee and ankle joint kinematic and knee kinetic data were collected for 17 right-handed female college badminton players using a 3-dimensional motion analysis system. Subjects performed single-left-legged landing after an overhead stroke following left and right back-stepping. The kinematic and kinetic data of the left lower extremities during landing were measured and compared between left and right back-steps. Hip flexion and abduction and knee valgus at the initial contact, hip and knee flexion and knee valgus at the maximum knee flexion and the maximum knee valgus moment were significantly larger for the left back-step than the right back-step (p<0.05). Significant differences in joint kinematics and kinetics of the lower extremity during single-leg landing after overhead stroke were observed between different back-step directions. Increased knee valgus angle and moment following back-stepping to the backhand-side might be related to the higher incidence of ACL injury during single-leg landing after overhead stroke.
NASA Astrophysics Data System (ADS)
Fu, Lin; Hu, Xiangyu Y.; Adams, Nikolaus A.
2017-12-01
We propose efficient single-step formulations for reinitialization and extending algorithms, which are critical components of level-set based interface-tracking methods. The level-set field is reinitialized with a single-step (non iterative) "forward tracing" algorithm. A minimum set of cells is defined that describes the interface, and reinitialization employs only data from these cells. Fluid states are extrapolated or extended across the interface by a single-step "backward tracing" algorithm. Both algorithms, which are motivated by analogy to ray-tracing, avoid multiple block-boundary data exchanges that are inevitable for iterative reinitialization and extending approaches within a parallel-computing environment. The single-step algorithms are combined with a multi-resolution conservative sharp-interface method and validated by a wide range of benchmark test cases. We demonstrate that the proposed reinitialization method achieves second-order accuracy in conserving the volume of each phase. The interface location is invariant to reapplication of the single-step reinitialization. Generally, we observe smaller absolute errors than for standard iterative reinitialization on the same grid. The computational efficiency is higher than for the standard and typical high-order iterative reinitialization methods. We observe a 2- to 6-times efficiency improvement over the standard method for serial execution. The proposed single-step extending algorithm, which is commonly employed for assigning data to ghost cells with ghost-fluid or conservative interface interaction methods, shows about 10-times efficiency improvement over the standard method while maintaining same accuracy. Despite their simplicity, the proposed algorithms offer an efficient and robust alternative to iterative reinitialization and extending methods for level-set based multi-phase simulations.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Velasco-Davalos, Ivan; Ambriz-Vargas, Fabian; Kolhatkar, Gitanjali
We report on a simple and fast procedure to create arrays of atomically flat terraces on single crystal SrTiO{sub 3} (111) substrates and the deposition of ferroelectric BiFeO{sub 3} thin films on such single-terminated surfaces. A microwave-assisted hydrothermal method in deionized water and ammonia solution selectively removes either (SrO{sub 3}){sup 4−} or Ti{sup 4+} layers to ensure the same chemical termination on all terraces. Measured step heights of 0.225 nm (d{sub 111}) and uniform contrast in the phase image of the terraces confirm the single termination in pure and Nb doped SrTiO{sub 3} single crystal substrates. Multiferroic BiFeO{sub 3} thinmore » films were then deposited by the same microwave assisted hydrothermal process on Nb : SrTiO{sub 3} (111) substrates. Bi(NO{sub 3}){sub 3} and Fe(NO{sub 3}){sub 3} along with KOH served as the precursors solution. Ferroelectric behavior of the BiFeO{sub 3} films on Nb : SrTiO{sub 3} (100) substrates was verified by piezoresponse force microscopy.« less
Bialek, Ralf; Kern, Jan; Herrmann, Tanja; Tijerina, Rolando; Ceceñas, Luis; Reischl, Udo; González, Gloria M.
2004-01-01
A conventional nested PCR and a real-time LightCycler PCR assay for detection of Coccidioides posadasii DNA were designed and tested in 120 clinical strains. These had been isolated from 114 patients within 10 years in Monterrey, Nuevo Leon, Mexico, known to be endemic for coccidioidomycosis. The gene encoding the specific antigen 2/proline-rich antigen (Ag2/PRA) was used as a target. All strains were correctly identified, whereas DNA from related members of the family Onygenaceae remained negative. Melting curve analysis by LightCycler and sequencing of the 526-bp product of the first PCR demonstrated either 100% identity to the GenBank sequence of the Silveira strain, now known to be C. posadasii (accession number AF013256), or a single silent mutation at position 1228. Length determination of two microsatellite-containing loci (GAC and 621) identified all 120 isolates as C. posadasii. Specific DNA was amplified by conventional nested PCR from three microscopically spherule-positive paraffin-embedded tissue samples, whereas 20 human tissue samples positive for other dimorphic fungi remained negative. Additionally, the safety of each step of a modified commercially available DNA extraction procedure was evaluated by using 10 strains. At least three steps of the protocol were demonstrated to sufficiently kill arthroconidia. This safe procedure is applicable to cultures and to clinical specimens. PMID:14766853
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huegli, R. W.; Messmer, P.; Jacob, A. L.
2003-09-15
Delayed or non-union of a sacral fracture is a serious clinical condition that may include chronic pain, sitting discomfort, gait disturbances, neurological problems, and inability to work. It is also a difficult reconstruction problem. Late correction of the deformity is technically more demanding than the primary treatment of acute pelvic injuries. Open reduction, internal fixation (ORIF), excision of scar tissue, and bone grafting often in a multi-step approach are considered to be the treatment of choice in delayed unions of the pelvic ring. This procedure implies the risk of neurological and vascular injuries, infection, repeated failure of union, incomplete correctionmore » of the deformity, and incomplete pain relief as the most important complications. We report a new approach for minimally invasive treatment of a delayed union of the sacrum without vertical displacement. A patient who suffered a Malgaigne fracture (Tile C1.3) was initially treated with closed reduction and percutaneous screw fixation (CRPF) of the posterior pelvic ring under CT navigation and plating of the anterior pelvic ring. Three months after surgery he presented with increasing hip pain caused by a delayed union of the sacral fracture. The lesion was successfully treated percutaneously in a single step procedure using CT navigation for drilling of the delayed union, autologous bone grafting, and screw fixation.« less
Past, Present, and Future of Minimally Invasive Abdominal Surgery
Antoniou, George A.; Antoniou, Athanasios I.; Granderath, Frank-Alexander
2015-01-01
Laparoscopic surgery has generated a revolution in operative medicine during the past few decades. Although strongly criticized during its early years, minimization of surgical trauma and the benefits of minimization to the patient have been brought to our attention through the efforts and vision of a few pioneers in the recent history of medicine. The German gynecologist Kurt Semm (1927–2003) transformed the use of laparoscopy for diagnostic purposes into a modern therapeutic surgical concept, having performed the first laparoscopic appendectomy, inspiring Erich Mühe and many other surgeons around the world to perform a wide spectrum of procedures by minimally invasive means. Laparoscopic cholecystectomy soon became the gold standard, and various laparoscopic procedures are now preferred over open approaches, in the light of emerging evidence that demonstrates less operative stress, reduced pain, and shorter convalescence. Natural orifice transluminal endoscopic surgery (NOTES) and single-incision laparoscopic surgery (SILS) may be considered further steps toward minimization of surgical trauma, although these methods have not yet been standardized. Laparoscopic surgery with the use of a robotic platform constitutes a promising field of investigation. New technologies are to be considered under the prism of the history of surgery; they seem to be a step toward further minimization of surgical trauma, but not definite therapeutic modalities. Patient safety and medical ethics must be the cornerstone of future investigation and implementation of new techniques. PMID:26508823
A parallel second-order adaptive mesh algorithm for incompressible flow in porous media.
Pau, George S H; Almgren, Ann S; Bell, John B; Lijewski, Michael J
2009-11-28
In this paper, we present a second-order accurate adaptive algorithm for solving multi-phase, incompressible flow in porous media. We assume a multi-phase form of Darcy's law with relative permeabilities given as a function of the phase saturation. The remaining equations express conservation of mass for the fluid constituents. In this setting, the total velocity, defined to be the sum of the phase velocities, is divergence free. The basic integration method is based on a total-velocity splitting approach in which we solve a second-order elliptic pressure equation to obtain a total velocity. This total velocity is then used to recast component conservation equations as nonlinear hyperbolic equations. Our approach to adaptive refinement uses a nested hierarchy of logically rectangular grids with simultaneous refinement of the grids in both space and time. The integration algorithm on the grid hierarchy is a recursive procedure in which coarse grids are advanced in time, fine grids are advanced multiple steps to reach the same time as the coarse grids and the data at different levels are then synchronized. The single-grid algorithm is described briefly, but the emphasis here is on the time-stepping procedure for the adaptive hierarchy. Numerical examples are presented to demonstrate the algorithm's accuracy and convergence properties and to illustrate the behaviour of the method.
Simulations of High Speed Fragment Trajectories
NASA Astrophysics Data System (ADS)
Yeh, Peter; Attaway, Stephen; Arunajatesan, Srinivasan; Fisher, Travis
2017-11-01
Flying shrapnel from an explosion are capable of traveling at supersonic speeds and distances much farther than expected due to aerodynamic interactions. Predicting the trajectories and stable tumbling modes of arbitrary shaped fragments is a fundamental problem applicable to range safety calculations, damage assessment, and military technology. Traditional approaches rely on characterizing fragment flight using a single drag coefficient, which may be inaccurate for fragments with large aspect ratios. In our work we develop a procedure to simulate trajectories of arbitrary shaped fragments with higher fidelity using high performance computing. We employ a two-step approach in which the force and moment coefficients are first computed as a function of orientation using compressible computational fluid dynamics. The force and moment data are then input into a six-degree-of-freedom rigid body dynamics solver to integrate trajectories in time. Results of these high fidelity simulations allow us to further understand the flight dynamics and tumbling modes of a single fragment. Furthermore, we use these results to determine the validity and uncertainty of inexpensive methods such as the single drag coefficient model.
78 FR 44189 - Petition for Modification of Single Car Air Brake Test Procedures
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-23
...] Petition for Modification of Single Car Air Brake Test Procedures In accordance with Part 232 of Title 49... Administration (FRA) per 49 CFR 232.307 to modify the single car air brake test procedures located in AAR Standard S-486, Code of Air Brake System Tests for Freight Equipment-- Single Car Test, and required...
Prevalence of gestational diabetes mellitus according to the different criterias
Akgöl, Evren; Abuşoğlu, Sedat; Gün, Faik Deniz; Ünlü, Ali
2017-01-01
Objective: The two-step approach recommended by the National Diabetes Data Group (NDDG), Carpenter and Coustan (C&C), and O’Sullivan, and the single-step approach recommended by the International Association of Diabetes and Pregnancy Study Group (IADPSG) are used to diagnose gestational diabetes mellitus (GDM). We aimed to determine GDM prevalence and to compare the two-step and single-step approaches used in the southeastern region of Turkey. Materials and Methods: In total, 3048 records of pregnant women screened for GDM between 2008 and 2014 were retrospectively extracted from our laboratory information system. GDM was defined according to the criteria of NDDG, C&C, and O’Sullivan between in 2008 and 2011, and according to those of the IADPSG between 2012 and 2014. Demographic variables were compared using student’s t-test. The linear trends in GDM prevalence with age were calculated using logistic regression. Results: GDM prevalence was found as 4.8%, 8%, and 13.4% using the NDDG, C&C, and O’Sullivan two-step approach, respectively, and 22.3% with the IADPSG single-step approach. GDM prevalence increased with increasing age in both approaches. Conclusion: GDM prevalence was higher using the single-step approach than with the two-step approach. There was a significant increase in GDM prevalence using the IADPSG criteria. PMID:28913130
Use of aluminum phosphate as the dehydration catalyst in single step dimethyl ether process
Peng, Xiang-Dong; Parris, Gene E.; Toseland, Bernard A.; Battavio, Paula J.
1998-01-01
The present invention pertains to a process for the coproduction of methanol and dimethyl ether (DME) directly from a synthesis gas in a single step (hereafter, the "single step DME process"). In this process, the synthesis gas comprising hydrogen and carbon oxides is contacted with a dual catalyst system comprising a physical mixture of a methanol synthesis catalyst and a methanol dehydration catalyst. The present invention is an improvement to this process for providing an active and stable catalyst system. The improvement comprises the use of an aluminum phosphate based catalyst as the methanol dehydration catalyst. Due to its moderate acidity, such a catalyst avoids the coke formation and catalyst interaction problems associated with the conventional dual catalyst systems taught for the single step DME process.
Melzer, Itshak; Goldring, Melissa; Melzer, Yehudit; Green, Elad; Tzedek, Irit
2010-12-01
If balance is lost, quick step execution can prevent falls. Research has shown that speed of voluntary stepping was able to predict future falls in old adults. The aim of the study was to investigate voluntary stepping behavior, as well as to compare timing and leg push-off force-time relation parameters of involved and uninvolved legs in stroke survivors during single- and dual-task conditions. We also aimed to compare timing and leg push-off force-time relation parameters between stroke survivors and healthy individuals in both task conditions. Ten stroke survivors performed a voluntary step execution test with their involved and uninvolved legs under two conditions: while focusing only on the stepping task and while a separate attention-demanding task was performed simultaneously. Temporal parameters related to the step time were measured including the duration of the step initiation phase, the preparatory phase, the swing phase, and the total step time. In addition, force-time parameters representing the push-off power during stepping were calculated from ground reaction data and compared with 10 healthy controls. The involved legs of stroke survivors had a significantly slower stepping time than uninvolved legs due to increased swing phase duration during both single- and dual-task conditions. For dual compared to single task, the stepping time increased significantly due to a significant increase in the duration of step initiation. In general, the force time parameters were significantly different in both legs of stroke survivors as compared to healthy controls, with no significant effect of dual compared with single-task conditions in both groups. The inability of stroke survivors to swing the involved leg quickly may be the most significant factor contributing to the large number of falls to the paretic side. The results suggest that stroke survivors were unable to rapidly produce muscle force in fast actions. This may be the mechanism of delayed execution of a fast step when balance is lost, thus increasing the likelihood of falls in stroke survivors. Copyright © 2010 Elsevier Ltd. All rights reserved.
2012-01-01
Residents in training, medical students and other staff in surgical sector, emergency room (ER) and intensive care unit (ICU) or Burn Unit face a multitude of questions regarding burn care. Treatment of burns is not always straightforward. Furthermore, National and International guidelines differ from one region to another. On one hand, it is important to understand pathophysiology, classification of burns, surgical treatment, and the latest updates in burn science. On the other hand, the clinical situation for treating these cases needs clear guidelines to cover every single aspect during the treatment procedure. Thus, 10 questions have been organised and discussed in a step-by-step form in order to achieve the excellence of education and the optimal treatment of burn injuries in the first 24 hours. These 10 questions will clearly discuss referral criteria to the burn unit, primary and secondary survey, estimation of the total burned surface area (%TBSA) and the degree of burns as well as resuscitation process, routine interventions, laboratory tests, indications of Bronchoscopy and special considerations for Inhalation trauma, immediate consultations and referrals, emergency surgery and admission orders. Understanding and answering the 10 questions will not only cover the management process of Burns during the first 24 hours but also seems to be an interactive clear guide for education purpose. PMID:22583548
Moreschi, Carlo; Broi, Ugo Da
2014-01-01
Clinical Practice Guidelines are clinical tools addressed to medical and health professionals and are normally employed to improve quality and safety of diagnostic and therapeutical procedures but may sometimes limit the autonomy of medical and other health care professionals. The adherence to Clinical Practice Guidelines should not be an exclusive step to evaluate the liability and respect of standards of care in case of medico-legal investigations being each clinical case very specific. Medical liability and respect of standards of care should be evaluated with the support of Clinical Practice Guidelines and the extensive examination of all specific features, professional background and experience requested to treat each single patient.
Pointwise influence matrices for functional-response regression.
Reiss, Philip T; Huang, Lei; Wu, Pei-Shien; Chen, Huaihou; Colcombe, Stan
2017-12-01
We extend the notion of an influence or hat matrix to regression with functional responses and scalar predictors. For responses depending linearly on a set of predictors, our definition is shown to reduce to the conventional influence matrix for linear models. The pointwise degrees of freedom, the trace of the pointwise influence matrix, are shown to have an adaptivity property that motivates a two-step bivariate smoother for modeling nonlinear dependence on a single predictor. This procedure adapts to varying complexity of the nonlinear model at different locations along the function, and thereby achieves better performance than competing tensor product smoothers in an analysis of the development of white matter microstructure in the brain. © 2017, The International Biometric Society.
Viguet-Carrin, S; Gineyts, E; Bertholon, C; Delmas, P D
2009-01-01
A rapid high performance liquid chromatographic method was developed including an internal standard for the measurement of mature and senescent crosslinks concentration in non-demineralized bone hydrolysates. To avoid the demineralization which is a tedious step, we developed a method based on the use of a solid-phase extraction procedure to clean-up the samples. It resulted in sensitive and accurate measurements: the detection limits as low as 0.2 pmol for the pyridimium crosslinks and 0.02 pmol for the pentosidine. The inter- and intra-assay coefficients of variation were as low as 5% and 2%, respectively, for all crosslinks.
NASA Astrophysics Data System (ADS)
Stefanakis, Dimitrios; Philippidis, Aggelos; Sygellou, Labrini; Filippidis, George; Ghanotakis, Demetrios; Anglos, Demetrios
2014-10-01
Two types of highly fluorescent carbon dots (C-dots) were prepared by a single-step procedure based on microwave heating citric acid and 6-aminocaproic acid or citric acid and urea in an aqueous solution. The small size of the isolated carbon dots along with their strong absorption in the UV and their excitation wavelength-dependent fluorescence render them ideal nanomaterials for biomedical applications (imaging and sensing). The structure and properties of the two types of C-dot materials were studied using a series of spectroscopic techniques. The ability of the C-dots to be internalized by HeLa cells was demonstrated via 3-photon fluorescence microscopy imaging.
Baur, M; Fedorov, A; Steffen, L; Filipp, S; da Silva, M P; Wallraff, A
2012-01-27
Teleportation of a quantum state may be used for distributing entanglement between distant qubits in quantum communication and for quantum computation. Here we demonstrate the implementation of a teleportation protocol, up to the single-shot measurement step, with superconducting qubits coupled to a microwave resonator. Using full quantum state tomography and evaluating an entanglement witness, we show that the protocol generates a genuine tripartite entangled state of all three qubits. Calculating the projection of the measured density matrix onto the basis states of two qubits allows us to reconstruct the teleported state. Repeating this procedure for a complete set of input states we find an average output state fidelity of 86%.
Use of EPANET solver to manage water distribution in Smart City
NASA Astrophysics Data System (ADS)
Antonowicz, A.; Brodziak, R.; Bylka, J.; Mazurkiewicz, J.; Wojtecki, S.; Zakrzewski, P.
2018-02-01
Paper presents a method of using EPANET solver to support manage water distribution system in Smart City. The main task is to develop the application that allows remote access to the simulation model of the water distribution network developed in the EPANET environment. Application allows to perform both single and cyclic simulations with the specified step of changing the values of the selected process variables. In the paper the architecture of application was shown. The application supports the selection of the best device control algorithm using optimization methods. Optimization procedures are possible with following methods: brute force, SLSQP (Sequential Least SQuares Programming), Modified Powell Method. Article was supplemented by example of using developed computer tool.
Prchal, Jan; Junkova, Petra; Strmiskova, Miroslava; Lipov, Jan; Hynek, Radovan; Ruml, Tomas; Hrabal, Richard
2011-09-01
Matrix proteins play multiple roles both in early and late stages of the viral replication cycle. Their N-terminal myristoylation is important for interaction with the host cell membrane during virus budding. We used Escherichia coli, carrying N-myristoyltransferase gene, for the expression of the myristoylated His-tagged matrix protein of Mason-Pfizer monkey virus. An efficient, single-step purification procedure eliminating all contaminating proteins including, importantly, the non-myristoylated matrix protein was designed. The comparison of NMR spectra of matrix protein with its myristoylated form revealed substantial structural changes induced by this fatty acid modification. Copyright © 2011 Elsevier Inc. All rights reserved.
Gas diffusion as a new fluidic unit operation for centrifugal microfluidic platforms.
Ymbern, Oriol; Sández, Natàlia; Calvo-López, Antonio; Puyol, Mar; Alonso-Chamarro, Julian
2014-03-07
A centrifugal microfluidic platform prototype with an integrated membrane for gas diffusion is presented for the first time. The centrifugal platform allows multiple and parallel analysis on a single disk and integrates at least ten independent microfluidic subunits, which allow both calibration and sample determination. It is constructed with a polymeric substrate material and it is designed to perform colorimetric determinations by the use of a simple miniaturized optical detection system. The determination of three different analytes, sulfur dioxide, nitrite and carbon dioxide, is carried out as a proof of concept of a versatile microfluidic system for the determination of analytes which involve a gas diffusion separation step during the analytical procedure.
ERIC Educational Resources Information Center
Deal, Gerald A.; Montgomery, James A.
This guide describes standard operating job procedures for the screening and grinding process of wastewater treatment facilities. The objective of this process is the removal of coarse materials from the raw waste stream for the protection of subsequent equipment and processes. The guide gives step-by-step instructions for safety inspection,…
ERIC Educational Resources Information Center
Schwing, Carl M.
This guide describes standard operating job procedures for the screening and grinding process of wastewater treatment facilities. The objective of this process is the removal of coarse materials from the raw waste stream for the protection of subsequent equipment and processes. The guide gives step-by-step instructions for safety inspection,…
ERIC Educational Resources Information Center
Schwing, Carl M.
This guide describes standard operating job procedures for the digestion process of wastewater treatment facilities. This process is for reducing the volume of sludge to be treated in subsequent units and to reduce the volatile content of sludge. The guide gives step-by-step instructions for pre-startup, startup, continuous operating, shutdown,…
ERIC Educational Resources Information Center
Petrasek, Al, Jr.
This guide describes the standard operating job procedures for the tertiary multimedia filtration process of wastewater treatment plants. The major objective of the filtration process is the removal of suspended solids from the reclaimed wastewater. The guide gives step-by-step instructions for pre-start up, start-up, continuous operation, and…
ERIC Educational Resources Information Center
Murph, Debra; McCormick, Sandra
1985-01-01
A 12-step procedure was used in teaching five minimally literate, male juvenile offenders to read and interpret prototypes of road signs displaying words, and a 5-step procedure for interpreting a sign without words. All students' correct responses in reading and interpreting signs increased and were maintained during subsequent post-checks.…
Practices & Procedures of Mason Tending I & II. Instructor Manual. Trainee Manual.
ERIC Educational Resources Information Center
Laborers-AGC Education and Training Fund, Pomfret Center, CT.
This packet consists of the instructor and trainee manuals for two courses: practices and procedures of mason tending I and II. The instructor manual for mason tending I contains a schedule for a 40-hour, 5-day course and instructor outline. The outline provides a step-by-step description of the instructor's activities and includes answer sheets…
ERIC Educational Resources Information Center
Garrett, Teresa A.; Osmundson, Joseph; Isaacson, Marisa; Herrera, Jennifer
2015-01-01
In traditional introductory biochemistry laboratory classes students learn techniques for protein purification and analysis by following provided, established, step-by-step procedures. Students are exposed to a variety of biochemical techniques but are often not developing procedures or collecting new, original data. In this laboratory module,…
ERIC Educational Resources Information Center
Wilder, David A.; Myers, Kristin; Fischetti, Anthony; Leon, Yanerys; Nicholson, Katie; Allison, Janelle
2012-01-01
After a 3-step guided compliance procedure (vocal prompt, vocal plus model prompt, vocal prompt plus physical guidance) did not increase compliance, we evaluated 2 modifications with 4 preschool children who exhibited noncompliance. The first modification consisted of omission of the model prompt, and the second modification consisted of omitting…
Effects of dual task on turning ability in stroke survivors and older adults.
Hollands, K L; Agnihotri, D; Tyson, S F
2014-09-01
Turning is an integral component of independent mobility in which stroke survivors frequently fall. This study sought to measure the effects of competing cognitive demands on the stepping patterns of stroke survivors, compared to healthy age-match adults, during turning as a putative mechanism for falls. Walking and turning (90°) was assessed under single (walking and turning alone) and dual task (subtracting serial 3s while walking and turning) conditions using an electronic, pressure-sensitive walkway. Dependent measures were time to turn, variability in time to turn, step length, step width and single support time during three steps of the turn. Turning ability in single and dual task conditions was compared between stroke survivors (n=17, mean ± SD: 59 ± 113 months post-stroke, 64 ± 10 years of age) and age-matched healthy counterparts (n=15). Both groups took longer, were more variable, tended to widen the second step and, crucially, increased single support time on the inside leg of the turn while turning and distracted. Increased single support time during turning may represent biomechanical mechanism, within stepping patterns of turning under distraction, for increased risk of falls for both stroke survivors and older adults. Crown Copyright © 2014. Published by Elsevier B.V. All rights reserved.
Al-Abdulla, Ibrahim; Casewell, Nicholas R; Landon, John
2014-01-15
Antivenoms are typically produced in horses or sheep and often purified using salt precipitation of immunoglobulins or F(ab')2 fragments. Caprylic (octanoic) acid fractionation of antiserum has the advantage of not precipitating the desired antibodies, thereby avoiding potential degradation that can lead to the formation of aggregates, which may be the cause of some adverse reactions to antivenoms. Here we report that when optimising the purification of immunoglobulins from ovine antiserum raised against snake venom, caprylic acid was found to have no effect on the activity of the enzymes pepsin and papain, which are employed in antivenom manufacturing to digest immunoglobulins to obtain F(ab')2 and Fab fragments, respectively. A "single-reagent" method was developed for the production of F(ab')2 antivenom whereby whole ovine antiserum was mixed with both caprylic acid and pepsin and incubated for 4h at 37°C. For ovine Fab antivenom production from whole antiserum, the "single reagent" comprised of caprylic acid, papain and l-cysteine; after incubation at 37°C for 18-20h, iodoacetamide was added to stop the reaction. Caprylic acid facilitated the precipitation of albumin, resulting in a reduced protein load presented to the digestion enzymes, culminating in substantial reductions in processing time. The ovine IgG, F(ab')2 and Fab products obtained using these novel caprylic acid methods were comparable in terms of yield, purity and specific activity to those obtained by multi-step conventional salt fractionation with sodium sulphate. Copyright © 2013 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
Crosby, Robert H.
1992-01-01
The Integrated Receiver/Decoder (IRD) currently used on the Space Shuttle was designed in the 1980 and prior time frame. Over the past 12 years, several parts have become obsolete or difficult to obtain. As directed by the Marshall Space Flight Center, a primary objective is to investigate updating the IRD design using the latest technology subsystems. To take advantage of experience with the current designs, an analysis of failures and a review of discrepancy reports, material review board actions, scrap, etc. are given. A recommended new design designated as the Advanced Receiver/Decoder (ARD) is presented. This design uses the latest technology components to simplify circuits, improve performance, reduce size and cost, and improve reliability. A self-test command is recommended that can improve and simplify operational procedures. Here, the new design is contrasted with the old. Possible simplification of the total Range Safety System is discussed, as is a single-step crypto technique that can improve and simplify operational procedures.
NASA Technical Reports Server (NTRS)
Braun, W. R.
1981-01-01
Pseudo noise (PN) spread spectrum systems require a very accurate alignment between the PN code epochs at the transmitter and receiver. This synchronism is typically established through a two-step algorithm, including a coarse synchronization procedure and a fine synchronization procedure. A standard approach for the coarse synchronization is a sequential search over all code phases. The measurement of the power in the filtered signal is used to either accept or reject the code phase under test as the phase of the received PN code. This acquisition strategy, called a single dwell-time system, has been analyzed by Holmes and Chen (1977). A synopsis of the field of sequential analysis as it applies to the PN acquisition problem is provided. From this, the implementation of the variable dwell time algorithm as a sequential probability ratio test is developed. The performance of this algorithm is compared to the optimum detection algorithm and to the fixed dwell-time system.
NASA Astrophysics Data System (ADS)
Palfreyman, Justin J.; Beldon, Patrick; Hong, Bingyan; Vyas, Kunal N.; Cooper, Joshaniel F. K.; Mitrelias, Thanos; Barnes, Crispin H. W.
2010-12-01
Rows of rectangular magnetic elements with different aspect ratio are encapsulated in polymer microcarriers to form a novel magnetic label, or tag, for multiplexed biological and chemical assays. We demonstrate that each tag can be encoded using an external magnetic field applied to the whole tag, which will allow for in-flow writing, thanks to shape-anisotropy controlled coercivity of the individual bits. This paper focuses on the fabrication of our 2nd generation tags, which facilitate optical trapping, do not require a sacrificial release layer, and the alignment procedure has been simplified to a single step. A new procedure is described for recovering a functional surface from fully cross-linked SU-8 via a cerium (IV) ammonium nitrate based chemical etch, and a novel method for releasing patterned photoresist from a bare Si wafer is discussed. In addition, a series of homobifunctional amine spacer compounds are compared as a method of increasing the binding efficiency of surface probe molecules.
NASA Technical Reports Server (NTRS)
1974-01-01
The purpose of the BRAVO User's Manual is to describe the BRAVO methodology in terms of step-by-step procedures. The BRAVO methodology then becomes a tool which a team of analysts can utilize to perform cost effectiveness analyses on potential future space applications with a relatively general set of input information and a relatively small expenditure of resources. An overview of the BRAVO procedure is given by describing the complete procedure in a general form.
Wester, T; Borg, H; Naji, H; Stenström, P; Westbacke, G; Lilja, H E
2014-09-01
Serial transverse enteroplasty (STEP) was first described in 2003 as a method for lengthening and tapering of the bowel in short bowel syndrome. The aim of this multicentre study was to review the outcome of a Swedish cohort of children who underwent STEP. All children who had a STEP procedure at one of the four centres of paediatric surgery in Sweden between September 2005 and January 2013 were included in this observational cohort study. Demographic details, and data from the time of STEP and at follow-up were collected from the case records and analysed. Twelve patients had a total of 16 STEP procedures; four children underwent a second STEP. The first STEP was performed at a median age of 5·8 (range 0·9-19·0) months. There was no death at a median follow-up of 37·2 (range 3·0-87·5) months and no child had small bowel transplantation. Seven of the 12 children were weaned from parenteral nutrition at a median of 19·5 (range 2·3-42·9) months after STEP. STEP is a useful procedure for selected patients with short bowel syndrome and seems to facilitate weaning from parenteral nutrition. At mid-term follow-up a majority of the children had achieved enteral autonomy. The study is limited by the small sample size and lack of a control group. © 2014 The Authors. BJS published by John Wiley & Sons Ltd on behalf of BJS Society Ltd.
Handling of Diskus dry powder inhaler in Chinese chronic obstructive pulmonary disease patients.
Li, Huaidong; Chen, Yuanyuan; Zhang, Zhaorui; Dong, Xiaoxuan; Zhang, Guogang; Zhang, Hui
2014-06-01
The incorrect handling of Diskus inhalers in Chinese patients with chronic obstructive pulmonary disease (COPD) is not well documented. The present study was conducted to evaluate in detail the handling errors related to the Diskus device, and to elucidate the importance of educating COPD patients on the proper use of the device. A total of 384 COPD patients from a pulmonary clinic in China over a period of 5 years were included in the study. The compliance of COPD patients to the 13 discrete steps of Diskus usage were scored and analyzed by three measures: (1) On day 0, patients were given only a package insert on Diskus, and the handling error rate was assessed. Then the patients were given instruction on the 13-step Diskus procedure until they could demonstrate the proper technique. (2) On days 1, 2, and 3, the observation group was continuously educated on a 13-step procedure, and the percentage of patients who scored 100% for each step was recorded. The control group had no such training. (3) On days 10, 20, and 30, the percentage of all subjects correctly performing the Diskus 13-step inhalation procedure was assessed. Incorrect handling techniques on Diskus usage were widely distributed among Chinese COPD patients. Step 8 ("Inhale forcefully from the beginning, slowly, deeply, and uniformly during the inspiratory phase until the lungs are full") was the most commonly mishandled step (93.8%). The total score and individual step scores of the patients from the observation group were significantly improved during 3-day continuous education. There was also a significantly higher percentage of correctly performed steps in the observation group than in the control group upon assessment on day 10 (96.24% vs. 85.63%, respectively; p<0.01), day 20 (97.31% vs. 86.09%, respectively; p<0.01), and day 30 (98.19% vs. 87.39%, respectively; p<0.01). Handling errors of the Diskus 13-step inhalation procedure were commonly observed in Chinese COPD patients. Continuous educational interventions and regular supervision by health-care providers are therefore crucial for the optimum use of the Diskus inhaler.
Endobronchial valves for bronchopleural fistula: pitfalls and principles.
Gaspard, Dany; Bartter, Thaddeus; Boujaoude, Ziad; Raja, Haroon; Arya, Rohan; Meena, Nikhil; Abouzgheib, Wissam
2017-01-01
Placement of endobronchial valves for bronchopleural fistula (BPF) is not always straightforward. A simple guide to the steps for an uncomplicated procedure does not encompass pitfalls that need to be understood and overcome to maximize the efficacy of this modality. The objective of this study was to discuss examples of difficult cases for which the placement of endobronchial valves was not straightforward and required alterations in the usual basic steps. Subsequently, we aimed to provide guiding principles for a successful procedure. Six illustrative cases were selected to demonstrate issues that can arise during endobronchial valve placement. In each case, a real or apparent lack of decrease in airflow through a BPF was diagnosed and addressed. We have used the selected problem cases to illustrate principles, with the goal of helping to increase the success rate for endobronchial valve placement in the treatment of BPF. This series demonstrates issues that complicate effective placement of endobronchial valves for BPF. These issues form the basis for troubleshooting steps that complement the basic procedural steps.
Toward Contactless Biology: Acoustophoretic DNA Transfection
NASA Astrophysics Data System (ADS)
Vasileiou, Thomas; Foresti, Daniele; Bayram, Adem; Poulikakos, Dimos; Ferrari, Aldo
2016-02-01
Acoustophoresis revolutionized the field of container-less manipulation of liquids and solids by enabling mixing procedures which avoid contamination and loss of reagents due to the contact with the support. While its applications to chemistry and engineering are straightforward, additional developments are needed to obtain reliable biological protocols in a contactless environment. Here, we provide a first, fundamental step towards biological reactions in air by demonstrating the acoustophoretic DNA transfection of mammalian cells. We developed an original acoustophoretic design capable of levitating, moving and mixing biological suspensions of living mammalians cells and of DNA plasmids. The precise and sequential delivery of the mixed solutions into tissue culture plates is actuated by a novel mechanism based on the controlled actuation of the acoustophoretic force. The viability of the contactless procedure is tested using a cellular model sensitive to small perturbation of neuronal differentiation pathways. Additionally, the efficiency of the transfection procedure is compared to standard, container-based methods for both single and double DNA transfection and for different cell types including adherent growing HeLa cancer cells, and low adhesion neuron-like PC12 cells. In all, this work provides a proof of principle which paves the way to the development of high-throughput acoustophoretic biological reactors.
Toward Contactless Biology: Acoustophoretic DNA Transfection.
Vasileiou, Thomas; Foresti, Daniele; Bayram, Adem; Poulikakos, Dimos; Ferrari, Aldo
2016-02-01
Acoustophoresis revolutionized the field of container-less manipulation of liquids and solids by enabling mixing procedures which avoid contamination and loss of reagents due to the contact with the support. While its applications to chemistry and engineering are straightforward, additional developments are needed to obtain reliable biological protocols in a contactless environment. Here, we provide a first, fundamental step towards biological reactions in air by demonstrating the acoustophoretic DNA transfection of mammalian cells. We developed an original acoustophoretic design capable of levitating, moving and mixing biological suspensions of living mammalians cells and of DNA plasmids. The precise and sequential delivery of the mixed solutions into tissue culture plates is actuated by a novel mechanism based on the controlled actuation of the acoustophoretic force. The viability of the contactless procedure is tested using a cellular model sensitive to small perturbation of neuronal differentiation pathways. Additionally, the efficiency of the transfection procedure is compared to standard, container-based methods for both single and double DNA transfection and for different cell types including adherent growing HeLa cancer cells, and low adhesion neuron-like PC12 cells. In all, this work provides a proof of principle which paves the way to the development of high-throughput acoustophoretic biological reactors.
NASA Astrophysics Data System (ADS)
Hilpert, Reinhold; Bauer, Christian; Binder, Florian; Grol, Michael; Hallermayer, Klaus; Josel, Hans-Peter; Klein, Christian; Maier, Josef; Makower, Alexander; Oberpriller, Helmut; Ritter, Josef
1994-10-01
In a joint project of Deutsche Aerospace, Boehringer Mannheim and the University of Potsdam portable devices for the detection of illegal drugs, based on biosensor technology, are being developed. The concept enrichment of the drug from the gas phase and detection by immunological means. This publication covers the development of specific antibodies and various detection procedures. Antibodies with a high affinity for cocaine have been developed with the aid of specially synthesized immunogens. A competitive detection procedure with biosensors based on optical grating couplers and applying particulate labels has been established, showing a lower detection limit of 10-10 mol/l for cocaine. Additionally, a combination of a displacement-immunoreactor and an enzymatically amplified electrode was investigated, which at present still suffers from insufficient sensitivity of the immunoreactor. An alternative, fleece-matrix based test procedure, where enrichment and detection steps are integrated in a single unit, is promising in terms of simplicity and sensitivity. A simple swab-test for the detection of cocaine at surfaces has been developed, which has a lower detection limit of about 10 ng and which can be performed within one minute.
Toward Contactless Biology: Acoustophoretic DNA Transfection
Vasileiou, Thomas; Foresti, Daniele; Bayram, Adem; Poulikakos, Dimos; Ferrari, Aldo
2016-01-01
Acoustophoresis revolutionized the field of container-less manipulation of liquids and solids by enabling mixing procedures which avoid contamination and loss of reagents due to the contact with the support. While its applications to chemistry and engineering are straightforward, additional developments are needed to obtain reliable biological protocols in a contactless environment. Here, we provide a first, fundamental step towards biological reactions in air by demonstrating the acoustophoretic DNA transfection of mammalian cells. We developed an original acoustophoretic design capable of levitating, moving and mixing biological suspensions of living mammalians cells and of DNA plasmids. The precise and sequential delivery of the mixed solutions into tissue culture plates is actuated by a novel mechanism based on the controlled actuation of the acoustophoretic force. The viability of the contactless procedure is tested using a cellular model sensitive to small perturbation of neuronal differentiation pathways. Additionally, the efficiency of the transfection procedure is compared to standard, container-based methods for both single and double DNA transfection and for different cell types including adherent growing HeLa cancer cells, and low adhesion neuron-like PC12 cells. In all, this work provides a proof of principle which paves the way to the development of high-throughput acoustophoretic biological reactors. PMID:26828312
Sullivan, Maura E; Yates, Kenneth A; Inaba, Kenji; Lam, Lydia; Clark, Richard E
2014-05-01
Because of the automated nature of knowledge, experts tend to omit information when describing a task. A potential solution is cognitive task analysis (CTA). The authors investigated the percentage of knowledge experts omitted when teaching a cricothyrotomy to determine the percentage of additional knowledge gained during a CTA interview. Three experts were videotaped teaching a cricothyrotomy in 2010 at the University of Southern California. After transcription, they participated in CTA interviews for the same procedure. Three additional surgeons were recruited to perform a CTA for the procedure, and a "gold standard" task list was created. Transcriptions from the teaching sessions were compared with the task list to identify omitted steps (both "what" and "how" to do). Transcripts from the CTA interviews were compared against the task list to determine the percentage of knowledge articulated by each expert during the initial "free recall" (unprompted) phase of the CTA interview versus the amount of knowledge gained by using CTA elicitation techniques (prompted). Experts omitted an average of 71% (10/14) of clinical knowledge steps, 51% (14/27) of action steps, and 73% (3.6/5) of decision steps. For action steps, experts described "how to do it" only 13% (3.6/27) of the time. The average number of steps that were described increased from 44% (20/46) when unprompted to 66% (31/46) when prompted. This study supports previous research that experts unintentionally omit knowledge when describing a procedure. CTA is a useful method to extract automated knowledge and augment expert knowledge recall during teaching.
Sun, Xiaojing; Wang, Yihua; Ajtai, Katalin
2017-01-01
Myosin motors in cardiac ventriculum convert ATP free energy to the work of moving blood volume under pressure. The actin bound motor cyclically rotates its lever-arm/light-chain complex linking motor generated torque to the myosin filament backbone and translating actin against resisting force. Previous research showed that the unloaded in vitro motor is described with high precision by single molecule mechanical characteristics including unitary step-sizes of approximately 3, 5, and 8 nm and their relative step-frequencies of approximately 13, 50, and 37%. The 3 and 8 nm unitary step-sizes are dependent on myosin essential light chain (ELC) N-terminus actin binding. Step-size and step-frequency quantitation specifies in vitro motor function including duty-ratio, power, and strain sensitivity metrics. In vivo, motors integrated into the muscle sarcomere form the more complex and hierarchically functioning muscle machine. The goal of the research reported here is to measure single myosin step-size and step-frequency in vivo to assess how tissue integration impacts motor function. A photoactivatable GFP tags the ventriculum myosin lever-arm/light-chain complex in the beating heart of a live zebrafish embryo. Detected single GFP emission reports time-resolved myosin lever-arm orientation interpreted as step-size and step-frequency providing single myosin mechanical characteristics over the active cycle. Following step-frequency of cardiac ventriculum myosin transitioning from low to high force in relaxed to auxotonic to isometric contraction phases indicates that the imposition of resisting force during contraction causes the motor to down-shift to the 3 nm step-size accounting for >80% of all the steps in the near-isometric phase. At peak force, the ATP initiated actomyosin dissociation is the predominant strain inhibited transition in the native myosin contraction cycle. The proposed model for motor down-shifting and strain sensing involves ELC N-terminus actin binding. Overall, the approach is a unique bottom-up single molecule mechanical characterization of a hierarchically functional native muscle myosin. PMID:28423017
Rapee, Ronald M; Lyneham, Heidi J; Wuthrich, Viviana; Chatterton, Mary Lou; Hudson, Jennifer L; Kangas, Maria; Mihalopoulos, Cathrine
2017-10-01
Stepped care is embraced as an ideal model of service delivery but is minimally evaluated. The aim of this study was to evaluate the efficacy of cognitive-behavioral therapy (CBT) for child anxiety delivered via a stepped-care framework compared against a single, empirically validated program. A total of 281 youth with anxiety disorders (6-17 years of age) were randomly allocated to receive either empirically validated treatment or stepped care involving the following: (1) low intensity; (2) standard CBT; and (3) individually tailored treatment. Therapist qualifications increased at each step. Interventions did not differ significantly on any outcome measures. Total therapist time per child was significantly shorter to deliver stepped care (774 minutes) compared with best practice (897 minutes). Within stepped care, the first 2 steps returned the strongest treatment gains. Stepped care and a single empirically validated program for youth with anxiety produced similar efficacy, but stepped care required slightly less therapist time. Restricting stepped care to only steps 1 and 2 would have led to considerable time saving with modest loss in efficacy. Clinical trial registration information-A Randomised Controlled Trial of Standard Care Versus Stepped Care for Children and Adolescents With Anxiety Disorders; http://anzctr.org.au/; ACTRN12612000351819. Copyright © 2017 American Academy of Child and Adolescent Psychiatry. Published by Elsevier Inc. All rights reserved.
Step Forward. Single Parent/Homemaker Annual Report for the Fiscal Year 1990-1991.
ERIC Educational Resources Information Center
Kentucky Tech Region 5, Elizabethtown.
The Step Forward Single Parent/Homemaker Program in Elizabethtown, Kentucky, was developed to provide information on career opportunities and assist the target individuals in career assessment, career counseling, and goal setting in order to develop self-esteem and time management skills. During the second year of the Step Forward program in…
Moricoli, Diego; Muller, William A.; Carbonella, Damiano Cosimo; Balducci, Maria Cristina; Dominici, Sabrina; Fiori, Valentina; Watson, Richard; Weber, Evan; Cianfriglia, Maurizio; Scotlandi, Katia; Magnani, Mauro
2015-01-01
Migration of leukocytes into a site of inflammation involves several steps mediated by various families of adhesion molecules. CD99 play a significant role in transendothelial migration (TEM) of leukocytes. Inhibition of TEM by specific monoclonal antibody (mAb) can provide a potent therapeutic approach to treating inflammatory conditions. However, the therapeutic utilization of whole IgG can lead to an inappropriate activation of Fc receptor-expressing cells inducing serious adverse side effects due to cytokine release. In this regard, specific recombinant antibody in single chain variable fragments (scFvs) originated by phage library may offer a solution by affecting TEM function in a safe clinical context. However, this consideration requires large scale production of functional scFv antibodies under GMP conditions and hence, the absence of toxic reagents utilized for the solubilization and refolding steps of inclusion bodies that may discourage industrial application of these antibody fragments. In order to apply the scFv anti-CD99 named C7A in a clinical setting we herein describe an efficient and large scale production of the antibody fragments expressed in E.coli as insoluble protein avoiding gel filtration chromatography approach, and laborious refolding step pre- and post-purification. Using differential salt elution which is a simple, reproducible and effective procedure we are able to separate scFv in monomer format from aggregates. The purified scFv antibody C7A exhibits inhibitory activity comparable to an antagonistic conventional mAb, thus providing an excellent agent for blocking CD99 signalling. Thanks to the original purification protocol that can be extended to other scFvs that are expressed as inclusion bodies in bacterial systems, the scFv anti-CD99 C7A herein described represents the first step towards the construction of new antibody therapeutic. PMID:24798881
Acute Oral Toxicity Up-And-Down-Procedure
The Up-and-Down Procedure is an alternative acute toxicity test that provides a way to determine the toxicity of chemicals with fewer test animals by using sequential dosing steps. Find out about this test procedure.
NASA Astrophysics Data System (ADS)
Smid, Marek; Costa, Ana; Pebesma, Edzer; Granell, Carlos; Bhattacharya, Devanjan
2016-04-01
Human kind is currently predominantly urban based, and the majority of ever continuing population growth will take place in urban agglomerations. Urban systems are not only major drivers of climate change, but also the impact hot spots. Furthermore, climate change impacts are commonly managed at city scale. Therefore, assessing climate change impacts on urban systems is a very relevant subject of research. Climate and its impacts on all levels (local, meso and global scale) and also the inter-scale dependencies of those processes should be a subject to detail analysis. While global and regional projections of future climate are currently available, local-scale information is lacking. Hence, statistical downscaling methodologies represent a potentially efficient way to help to close this gap. In general, the methodological reviews of downscaling procedures cover the various methods according to their application (e.g. downscaling for the hydrological modelling). Some of the most recent and comprehensive studies, such as the ESSEM COST Action ES1102 (VALUE), use the concept of Perfect Prog and MOS. Other examples of classification schemes of downscaling techniques consider three main categories: linear methods, weather classifications and weather generators. Downscaling and climate modelling represent a multidisciplinary field, where researchers from various backgrounds intersect their efforts, resulting in specific terminology, which may be somewhat confusing. For instance, the Polynomial Regression (also called the Surface Trend Analysis) is a statistical technique. In the context of the spatial interpolation procedures, it is commonly classified as a deterministic technique, and kriging approaches are classified as stochastic. Furthermore, the terms "statistical" and "stochastic" (frequently used as names of sub-classes in downscaling methodological reviews) are not always considered as synonymous, even though both terms could be seen as identical since they are referring to methods handling input modelling factors as variables with certain probability distributions. In addition, the recent development is going towards multi-step methodologies containing deterministic and stochastic components. This evolution leads to the introduction of new terms like hybrid or semi-stochastic approaches, which makes the efforts to systematically classifying downscaling methods to the previously defined categories even more challenging. This work presents a review of statistical downscaling procedures, which classifies the methods in two steps. In the first step, we describe several techniques that produce a single climatic surface based on observations. The methods are classified into two categories using an approximation to the broadest consensual statistical terms: linear and non-linear methods. The second step covers techniques that use simulations to generate alternative surfaces, which correspond to different realizations of the same processes. Those simulations are essential because there is a limited number of real observational data, and such procedures are crucial for modelling extremes. This work emphasises the link between statistical downscaling methods and the research of climate change impacts at city scale.
Glais, Laurent; Jacquot, Emmanuel
2015-01-01
Numerous molecular-based detection protocols include an amplification step of the targeted nucleic acids. This step is important to reach the expected sensitive detection of pathogens in diagnostic procedures. Amplifications of nucleic acid sequences are generally performed, in the presence of appropriate primers, using thermocyclers. However, the time requested to amplify molecular targets and the cost of the thermocycler machines could impair the use of these methods in routine diagnostics. Recombinase polymerase amplification (RPA) technique allows rapid (short-term incubation of sample and primers in an enzymatic mixture) and simple (isothermal) amplification of molecular targets. RPA protocol requires only basic molecular steps such as extraction procedures and agarose gel electrophoresis. Thus, RPA can be considered as an interesting alternative to standard molecular-based diagnostic tools. In this paper, the complete procedures to set up an RPA assay, applied to detection of RNA (Potato virus Y, Potyvirus) and DNA (Wheat dwarf virus, Mastrevirus) viruses, are described. The proposed procedure allows developing species- or subspecies-specific detection assay.
Changes in step-width during dual-task walking predicts falls.
Nordin, E; Moe-Nilssen, R; Ramnemark, A; Lundin-Olsson, L
2010-05-01
The aim was to evaluate whether gait pattern changes between single- and dual-task conditions were associated with risk of falling in older people. Dual-task cost (DTC) of 230 community living, physically independent people, 75 years or older, was determined with an electronic walkway. Participants were followed up each month for 1 year to record falls. Mean and variability measures of gait characteristics for 5 dual-task conditions were compared to single-task walking for each participant. Almost half (48%) of the participants fell at least once during follow-up. Risk of falling increased in individuals where DTC for performing a subtraction task demonstrated change in mean step-width compared to single-task walking. Risk of falling decreased in individuals where DTC for carrying a cup and saucer demonstrated change compared to single-task walking in mean step-width, mean step-time, and step-length variability. Degree of change in gait characteristics related to a change in risk of falling differed between measures. Prognostic guidance for fall risk was found for the above DTCs in mean step-width with a negative likelihood ratio of 0.5 and a positive likelihood ratio of 2.3, respectively. Findings suggest that changes in step-width, step-time, and step-length with dual tasking may be related to future risk of falling. Depending on the nature of the second task, DTC may indicate either an increased risk of falling, or a protective strategy to avoid falling. Copyright 2010. Published by Elsevier B.V.
ERIC Educational Resources Information Center
Wilder, David A.; Atwell, Julie; Wine, Byron
2006-01-01
The effects of three levels of treatment integrity (100%, 50%, and 0%) on child compliance were evaluated in the context of the implementation of a three-step prompting procedure. Two typically developing preschool children participated in the study. After baseline data on compliance to one of three common demands were collected, a therapist…
Aseptic Laboratory Techniques: Plating Methods
Sanders, Erin R.
2012-01-01
Microorganisms are present on all inanimate surfaces creating ubiquitous sources of possible contamination in the laboratory. Experimental success relies on the ability of a scientist to sterilize work surfaces and equipment as well as prevent contact of sterile instruments and solutions with non-sterile surfaces. Here we present the steps for several plating methods routinely used in the laboratory to isolate, propagate, or enumerate microorganisms such as bacteria and phage. All five methods incorporate aseptic technique, or procedures that maintain the sterility of experimental materials. Procedures described include (1) streak-plating bacterial cultures to isolate single colonies, (2) pour-plating and (3) spread-plating to enumerate viable bacterial colonies, (4) soft agar overlays to isolate phage and enumerate plaques, and (5) replica-plating to transfer cells from one plate to another in an identical spatial pattern. These procedures can be performed at the laboratory bench, provided they involve non-pathogenic strains of microorganisms (Biosafety Level 1, BSL-1). If working with BSL-2 organisms, then these manipulations must take place in a biosafety cabinet. Consult the most current edition of the Biosafety in Microbiological and Biomedical Laboratories (BMBL) as well as Material Safety Data Sheets (MSDS) for Infectious Substances to determine the biohazard classification as well as the safety precautions and containment facilities required for the microorganism in question. Bacterial strains and phage stocks can be obtained from research investigators, companies, and collections maintained by particular organizations such as the American Type Culture Collection (ATCC). It is recommended that non-pathogenic strains be used when learning the various plating methods. By following the procedures described in this protocol, students should be able to: ● Perform plating procedures without contaminating media. ● Isolate single bacterial colonies by the streak-plating method. ● Use pour-plating and spread-plating methods to determine the concentration of bacteria. ● Perform soft agar overlays when working with phage. ● Transfer bacterial cells from one plate to another using the replica-plating procedure. ● Given an experimental task, select the appropriate plating method. PMID:22617405
Spacecraft crew procedures from paper to computers
NASA Technical Reports Server (NTRS)
Oneal, Michael; Manahan, Meera
1993-01-01
Large volumes of paper are launched with each Space Shuttle Mission that contain step-by-step instructions for various activities that are to be performed by the crew during the mission. These instructions include normal operational procedures and malfunction or contingency procedures and are collectively known as the Flight Data File (FDF). An example of nominal procedures would be those used in the deployment of a satellite from the Space Shuttle; a malfunction procedure would describe actions to be taken if a specific problem developed during the deployment. A new FDF and associated system is being created for Space Station Freedom. The system will be called the Space Station Flight Data File (SFDF). NASA has determined that the SFDF will be computer-based rather than paper-based. Various aspects of the SFDF are discussed.
Functional-to-form mapping for assembly design automation
NASA Astrophysics Data System (ADS)
Xu, Z. G.; Liu, W. M.; Shen, W. D.; Yang, D. Y.; Liu, T. T.
2017-11-01
Assembly-level function-to-form mapping is the most effective procedure towards design automation. The research work mainly includes: the assembly-level function definitions, product network model and the two-step mapping mechanisms. The function-to-form mapping is divided into two steps, i.e. mapping of function-to-behavior, called the first-step mapping, and the second-step mapping, i.e. mapping of behavior-to-structure. After the first step mapping, the three dimensional transmission chain (or 3D sketch) is studied, and the feasible design computing tools are developed. The mapping procedure is relatively easy to be implemented interactively, but, it is quite difficult to finish it automatically. So manual, semi-automatic, automatic and interactive modification of the mapping model are studied. A mechanical hand F-F mapping process is illustrated to verify the design methodologies.
Integrating Water Quality and River Rehabilitation Management - A Decision-Analytical Perspective
NASA Astrophysics Data System (ADS)
Reichert, P.; Langhans, S.; Lienert, J.; Schuwirth, N.
2009-04-01
Integrative river management involves difficult decisions about alternative measures to improve their ecological state. For this reason, it seems useful to apply knowledge from the decision sciences to support river management. We discuss how decision-analytical elements can be employed for designing an integrated river management procedure. An important aspect of this procedure is to clearly separate scientific predictions of the consequences of alternatives from objectives to be achieved by river management. The key elements of the suggested procedure are (i) the quantitative elicitation of the objectives from different stakeholder groups, (ii) the compilation of the current scientific knowledge about the consequences of the effects resulting from suggested measures in the form of a probabilistic mathematical model, and (iii) the use of these predictions and valuations to prioritize alternatives, to uncover conflicting objectives, to support the design of better alternatives, and to improve the transparency of communication about the chosen management strategy. The development of this procedure led to insights regarding necessary steps to be taken for rational decision-making in river management, to guidelines about the use of decision-analytical techniques for performing these steps, but also to new insights about the application of decision-analytical techniques in general. In particular, the consideration of the spatial distribution of the effects of measures and the potential added value of connected rehabilitated river reaches leads to favoring measures that have a positive effect beyond a single river reach. As these effects only propagate within the river network, this results in a river basin oriented management concept as a consequence of a rational decision support procedure, rather than as an a priori management paradigm. There are also limitations to the support that can be expected from the decision-analytical perspective. It will not provide the societal values that are driving prioritization in river management, it will only support their elicitation and rational use. This is particularly important for the assessment of micro-pollutants because of severe limitations in scientific knowledge of their effects on river ecosystems. This makes the influence of pollution by micro-pollutants on prioritization of measures strongly dependent on the weight of the precautionary principle relative to other societal objectives of river management.
Baker, Eddie G.; Elliott, Douglas C.
1993-01-01
The present invention is a multi-stepped method of converting an oil which is produced by various biomass and coal conversion processes and contains primarily single and multiple ring hydroxyaromatic hydrocarbon compounds to highly aromatic gasoline. The single and multiple ring hydroxyaromatic hydrocarbon compounds in a raw oil material are first deoxygenated to produce a deoxygenated oil material containing single and multiple ring aromatic compounds. Then, water is removed from the deoxygenated oil material. The next step is distillation to remove the single ring aromatic compouns as gasoline. In the third step, the multiple ring aromatics remaining in the deoxygenated oil material are cracked in the presence of hydrogen to produce a cracked oil material containing single ring aromatic compounds. Finally, the cracked oil material is then distilled to remove the single ring aromatics as gasoline.
Baker, E.G.; Elliott, D.C.
1993-01-19
The present invention is a multi-stepped method of converting an oil which is produced by various biomass and coal conversion processes and contains primarily single and multiple ring hydroxyaromatic hydrocarbon compounds to highly aromatic gasoline. The single and multiple ring hydroxyaromatic hydrocarbon compounds in a raw oil material are first deoxygenated to produce a deoxygenated oil material containing single and multiple ring aromatic compounds. Then, water is removed from the deoxygenated oil material. The next step is distillation to remove the single ring aromatic compounds as gasoline. In the third step, the multiple ring aromatics remaining in the deoxygenated oil material are cracked in the presence of hydrogen to produce a cracked oil material containing single ring aromatic compounds. Finally, the cracked oil material is then distilled to remove the single ring aromatics as gasoline.
Single molecule thermodynamics in biological motors.
Taniguchi, Yuichi; Karagiannis, Peter; Nishiyama, Masayoshi; Ishii, Yoshiharu; Yanagida, Toshio
2007-04-01
Biological molecular machines use thermal activation energy to carry out various functions. The process of thermal activation has the stochastic nature of output events that can be described according to the laws of thermodynamics. Recently developed single molecule detection techniques have allowed each distinct enzymatic event of single biological machines to be characterized providing clues to the underlying thermodynamics. In this study, the thermodynamic properties in the stepping movement of a biological molecular motor have been examined. A single molecule detection technique was used to measure the stepping movements at various loads and temperatures and a range of thermodynamic parameters associated with the production of each forward and backward step including free energy, enthalpy, entropy and characteristic distance were obtained. The results show that an asymmetry in entropy is a primary factor that controls the direction in which the motor will step. The investigation on single molecule thermodynamics has the potential to reveal dynamic properties underlying the mechanisms of how biological molecular machines work.
PVT: An Efficient Computational Procedure to Speed up Next-generation Sequence Analysis
2014-01-01
Background High-throughput Next-Generation Sequencing (NGS) techniques are advancing genomics and molecular biology research. This technology generates substantially large data which puts up a major challenge to the scientists for an efficient, cost and time effective solution to analyse such data. Further, for the different types of NGS data, there are certain common challenging steps involved in analysing those data. Spliced alignment is one such fundamental step in NGS data analysis which is extremely computational intensive as well as time consuming. There exists serious problem even with the most widely used spliced alignment tools. TopHat is one such widely used spliced alignment tools which although supports multithreading, does not efficiently utilize computational resources in terms of CPU utilization and memory. Here we have introduced PVT (Pipelined Version of TopHat) where we take up a modular approach by breaking TopHat’s serial execution into a pipeline of multiple stages, thereby increasing the degree of parallelization and computational resource utilization. Thus we address the discrepancies in TopHat so as to analyze large NGS data efficiently. Results We analysed the SRA dataset (SRX026839 and SRX026838) consisting of single end reads and SRA data SRR1027730 consisting of paired-end reads. We used TopHat v2.0.8 to analyse these datasets and noted the CPU usage, memory footprint and execution time during spliced alignment. With this basic information, we designed PVT, a pipelined version of TopHat that removes the redundant computational steps during ‘spliced alignment’ and breaks the job into a pipeline of multiple stages (each comprising of different step(s)) to improve its resource utilization, thus reducing the execution time. Conclusions PVT provides an improvement over TopHat for spliced alignment of NGS data analysis. PVT thus resulted in the reduction of the execution time to ~23% for the single end read dataset. Further, PVT designed for paired end reads showed an improved performance of ~41% over TopHat (for the chosen data) with respect to execution time. Moreover we propose PVT-Cloud which implements PVT pipeline in cloud computing system. PMID:24894600
PVT: an efficient computational procedure to speed up next-generation sequence analysis.
Maji, Ranjan Kumar; Sarkar, Arijita; Khatua, Sunirmal; Dasgupta, Subhasis; Ghosh, Zhumur
2014-06-04
High-throughput Next-Generation Sequencing (NGS) techniques are advancing genomics and molecular biology research. This technology generates substantially large data which puts up a major challenge to the scientists for an efficient, cost and time effective solution to analyse such data. Further, for the different types of NGS data, there are certain common challenging steps involved in analysing those data. Spliced alignment is one such fundamental step in NGS data analysis which is extremely computational intensive as well as time consuming. There exists serious problem even with the most widely used spliced alignment tools. TopHat is one such widely used spliced alignment tools which although supports multithreading, does not efficiently utilize computational resources in terms of CPU utilization and memory. Here we have introduced PVT (Pipelined Version of TopHat) where we take up a modular approach by breaking TopHat's serial execution into a pipeline of multiple stages, thereby increasing the degree of parallelization and computational resource utilization. Thus we address the discrepancies in TopHat so as to analyze large NGS data efficiently. We analysed the SRA dataset (SRX026839 and SRX026838) consisting of single end reads and SRA data SRR1027730 consisting of paired-end reads. We used TopHat v2.0.8 to analyse these datasets and noted the CPU usage, memory footprint and execution time during spliced alignment. With this basic information, we designed PVT, a pipelined version of TopHat that removes the redundant computational steps during 'spliced alignment' and breaks the job into a pipeline of multiple stages (each comprising of different step(s)) to improve its resource utilization, thus reducing the execution time. PVT provides an improvement over TopHat for spliced alignment of NGS data analysis. PVT thus resulted in the reduction of the execution time to ~23% for the single end read dataset. Further, PVT designed for paired end reads showed an improved performance of ~41% over TopHat (for the chosen data) with respect to execution time. Moreover we propose PVT-Cloud which implements PVT pipeline in cloud computing system.
Genomic prediction in a nuclear population of layers using single-step models.
Yan, Yiyuan; Wu, Guiqin; Liu, Aiqiao; Sun, Congjiao; Han, Wenpeng; Li, Guangqi; Yang, Ning
2018-02-01
Single-step genomic prediction method has been proposed to improve the accuracy of genomic prediction by incorporating information of both genotyped and ungenotyped animals. The objective of this study is to compare the prediction performance of single-step model with a 2-step models and the pedigree-based models in a nuclear population of layers. A total of 1,344 chickens across 4 generations were genotyped by a 600 K SNP chip. Four traits were analyzed, i.e., body weight at 28 wk (BW28), egg weight at 28 wk (EW28), laying rate at 38 wk (LR38), and Haugh unit at 36 wk (HU36). In predicting offsprings, individuals from generation 1 to 3 were used as training data and females from generation 4 were used as validation set. The accuracies of predicted breeding values by pedigree BLUP (PBLUP), genomic BLUP (GBLUP), SSGBLUP and single-step blending (SSBlending) were compared for both genotyped and ungenotyped individuals. For genotyped females, GBLUP performed no better than PBLUP because of the small size of training data, while the 2 single-step models predicted more accurately than the PBLUP model. The average predictive ability of SSGBLUP and SSBlending were 16.0% and 10.8% higher than the PBLUP model across traits, respectively. Furthermore, the predictive abilities for ungenotyped individuals were also enhanced. The average improvements of prediction abilities were 5.9% and 1.5% for SSGBLUP and SSBlending model, respectively. It was concluded that single-step models, especially the SSGBLUP model, can yield more accurate prediction of genetic merits and are preferable for practical implementation of genomic selection in layers. © 2017 Poultry Science Association Inc.
NASA Astrophysics Data System (ADS)
Yang, Yao-Joe; Kuo, Wen-Cheng; Fan, Kuang-Chao
2006-01-01
In this work, we present a single-run single-mask (SRM) process for fabricating suspended high-aspect-ratio structures on standard silicon wafers using an inductively coupled plasma-reactive ion etching (ICP-RIE) etcher. This process eliminates extra fabrication steps which are required for structure release after trench etching. Released microstructures with 120 μm thickness are obtained by this process. The corresponding maximum aspect ratio of the trench is 28. The SRM process is an extended version of the standard process proposed by BOSCH GmbH (BOSCH process). The first step of the SRM process is a standard BOSCH process for trench etching, then a polymer layer is deposited on trench sidewalls as a protective layer for the subsequent structure-releasing step. The structure is released by dry isotropic etching after the polymer layer on the trench floor is removed. All the steps can be integrated into a single-run ICP process. Also, only one mask is required. Therefore, the process complexity and fabrication cost can be effectively reduced. Discussions on each SRM step and considerations for avoiding undesired etching of the silicon structures during the release process are also presented.
Modular Training for Robot-Assisted Radical Prostatectomy: Where to Begin?
Lovegrove, Catherine; Ahmed, Kamran; Novara, Giacomo; Guru, Khurshid; Mottrie, Alex; Challacombe, Ben; der Poel, Henk Van; Peabody, James; Dasgupta, Prokar
Effective training is paramount for patient safety. Modular training entails advancing through surgical steps of increasing difficulty. This study aimed to construct a modular training pathway for use in robot-assisted radical prostatectomy (RARP). It aims to identify the sequence of procedural steps that are learnt before surgeons are able to perform a full procedure without an intervention from mentor. This is a multi-institutional, prospective, observational, longitudinal study. We used a validated training tool (RARP Score). Data regarding surgeons' stage of training and progress were collected for analysis. A modular training pathway was constructed with consensus on the level of difficulty and evaluation of individual steps. We identified and recorded the sequence of steps performed by fellows during their learning curves. We included 15 urology fellows from UK, Europe, and Australia. A total of 15 surgeons were assessed by mentors in 425 RARP cases over 8 months (range: 7-79) across 15 international centers. There were substantial differences in the sequence of RARP steps according to the chronology of the procedure, difficulty level, and the order in which surgeons actually learned steps. Steps were not attempted in chronological order. The greater the difficulty, the later the cohort first undertook the step (p = 0.021). The cohort undertook steps of difficulty level I at median case number 1. Steps of difficulty levels II, III, and IV showed more variation in median case number of the first attempt. We recommend that, in the operating theater, steps be learned in order of increasing difficulty. A new modular training route has been designed. This incorporates the steps of RARP with the following order of priority: difficulty level > median case number of first attempt > most frequently undertaken in surgical training. An evidence-based modular training pathway has been developed that facilitates a safe introduction to RARP for novice surgeons. Copyright © 2017 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.
Fox, Bridget C; Devonshire, Alison S; Baradez, Marc-Olivier; Marshall, Damian; Foy, Carole A
2012-08-15
Single cell gene expression analysis can provide insights into development and disease progression by profiling individual cellular responses as opposed to reporting the global average of a population. Reverse transcription-quantitative polymerase chain reaction (RT-qPCR) is the "gold standard" for the quantification of gene expression levels; however, the technical performance of kits and platforms aimed at single cell analysis has not been fully defined in terms of sensitivity and assay comparability. We compared three kits using purification columns (PicoPure) or direct lysis (CellsDirect and Cells-to-CT) combined with a one- or two-step RT-qPCR approach using dilutions of cells and RNA standards to the single cell level. Single cell-level messenger RNA (mRNA) analysis was possible using all three methods, although the precision, linearity, and effect of lysis buffer and cell background differed depending on the approach used. The impact of using a microfluidic qPCR platform versus a standard instrument was investigated for potential variability introduced by preamplification of template or scaling down of the qPCR to nanoliter volumes using laser-dissected single cell samples. The two approaches were found to be comparable. These studies show that accurate gene expression analysis is achievable at the single cell level and highlight the importance of well-validated experimental procedures for low-level mRNA analysis. Copyright © 2012 Elsevier Inc. All rights reserved.
Processing single-use medical devices for use in surgery - importance, status quo and potential.
Krüger, Colin M
2008-09-03
In summary, it is possible with the technology and scientific knowledge currently available to allow products intended for single use to be reprocessed using validated and certified processing procedures, while maintaining the full function and without any loss in quality. How many times a product can be re-processed must be determined separately for each individual medical technology device; it is not possible to make any kind of blanket statement as to the permissible number of cycles. This is due to the differing construction, the various combinations of materials and the diverse demands made of each device during clinical use. The exigency of the reprocessing issue is evident both to the user and the primary manufacturer. For the user, where there is a correspondingly high-quality primary product with suitably costed, technically-sound and certified reprocessing procedures, repeat usage can mean real savings while maintaining full functionality in each use. For the primary manufacturers of highly specialised instruments, only part of which can be represented by the medical facility in terms of a corresponding DRG (Diagnosis-Related Group), it is reprocessing that opens the door to widespread routine clinical use. The patient, in turn, benefits greatly from this, since his demand for medical treatment using the most up-to-date technology is taken into account. If processing complies in full with medical technology and hygiene directives, from the medical point of view (without being able to definitively evaluate each individual case using this criterion) the specific advantages of the reprocessing procedure are obvious. In order to establish broad acceptance for the purposes of good marketing, corresponding controlling and quality instruments have to be developed to allow the decision-making process regarding the permissibility of the reprocessing of a certain device and the number of times it can be reprocessed using this procedure to be made transparent.Taking this a step further, possibilities arise for the establishment of corresponding quality-assurance instruments on the part of the clinical establishments involved, within which reprocessed products, in the interest of quality assurance, can be referred back to the processor in the event of defective function and can also be removed from clinical use prior to completing the intended number of processing cycles. Furthermore, it can be assumed that the widespread use of reprocessing procedures in today's high-cost single-use medical device sector will have a long-term cost/price-regulating effect for the primary products, to the benefit of the users. Thus, the heated debate regarding the safety of processing procedures that have already been certified and validated in accordance with current industry standards should be evaluated in particular from the point of view of the justified fears of the leading manufacturers with regard to their currently established market share. From a purely surgical point of view, the reprocessing of disposable products should be welcomed as a revolution. The main criteria for surgeons and medics should always be the benefit for the patient. If the quality is ensured through corresponding processing and validation procedures based on recognised certificates, then economic arguments take precedence. Cases in which a DRG (and thus a payment calculation) does not fully cover the use of medical devices are conceivable. Withholding medically necessary services on grounds of the costs, or making these services available to a limited extent only, is not acceptable from the medical point of view and furthermore goes beyond what is ethically acceptable. Each procedure, even the systematic use of reprocessing of suitable medical technology disposable items, should, where the quality is guaranteed, be supported unequivocally. Taken a step further, this branch of the economy will have a long-lasting price-regulating effect on the primary producers market.
Optimal configuration of microstructure in ferroelectric materials by stochastic optimization
NASA Astrophysics Data System (ADS)
Jayachandran, K. P.; Guedes, J. M.; Rodrigues, H. C.
2010-07-01
An optimization procedure determining the ideal configuration at the microstructural level of ferroelectric (FE) materials is applied to maximize piezoelectricity. Piezoelectricity in ceramic FEs differs significantly from that of single crystals because of the presence of crystallites (grains) possessing crystallographic axes aligned imperfectly. The piezoelectric properties of a polycrystalline (ceramic) FE is inextricably related to the grain orientation distribution (texture). The set of combination of variables, known as solution space, which dictates the texture of a ceramic is unlimited and hence the choice of the optimal solution which maximizes the piezoelectricity is complicated. Thus, a stochastic global optimization combined with homogenization is employed for the identification of the optimal granular configuration of the FE ceramic microstructure with optimum piezoelectric properties. The macroscopic equilibrium piezoelectric properties of polycrystalline FE is calculated using mathematical homogenization at each iteration step. The configuration of grains characterized by its orientations at each iteration is generated using a randomly selected set of orientation distribution parameters. The optimization procedure applied to the single crystalline phase compares well with the experimental data. Apparent enhancement of piezoelectric coefficient d33 is observed in an optimally oriented BaTiO3 single crystal. Based on the good agreement of results with the published data in single crystals, we proceed to apply the methodology in polycrystals. A configuration of crystallites, simultaneously constraining the orientation distribution of the c-axis (polar axis) while incorporating ab-plane randomness, which would multiply the overall piezoelectricity in ceramic BaTiO3 is also identified. The orientation distribution of the c-axes is found to be a narrow Gaussian distribution centered around 45°. The piezoelectric coefficient in such a ceramic is found to be nearly three times as that of the single crystal. Our optimization model provide designs for materials with enhanced piezoelectric performance, which would stimulate further studies involving materials possessing higher spontaneous polarization.
Evaluation of a procedure for reducing vehicle-tree accidents.
DOT National Transportation Integrated Search
1987-01-01
A procedure for reducing vehicle-tree accidents was evaluated. The procedure, developed by the Michigan Department of Transportation, consists of five steps: (1) preparing a base map and plotting roadway information, (2) assigning priorities for fiel...
Přibyl, J; Bauer, J; Čermák, V; Pešek, P; Přibylová, J; Šplíchal, J; Vostrá-Vydrová, H; Vostrý, L; Zavadilová, L
2015-10-01
Estimated breeding values (EBVs) and genomic enhanced breeding values (GEBVs) for milk production of young genotyped Holstein bulls were predicted using a conventional BLUP - Animal Model, a method fitting regression coefficients for loci (RRBLUP), a method utilizing the realized genomic relationship matrix (GBLUP), by a single-step procedure (ssGBLUP) and by a one-step blending procedure. Information sources for prediction were the nation-wide database of domestic Czech production records in the first lactation combined with deregressed proofs (DRP) from Interbull files (August 2013) and domestic test-day (TD) records for the first three lactations. Data from 2627 genotyped bulls were used, of which 2189 were already proven under domestic conditions. Analyses were run that used Interbull values for genotyped bulls only or that used Interbull values for all available sires. Resultant predictions were compared with GEBV of 96 young foreign bulls evaluated abroad and whose proofs were from Interbull method GMACE (August 2013) on the Czech scale. Correlations of predictions with GMACE values of foreign bulls ranged from 0.33 to 0.75. Combining domestic data with Interbull EBVs improved prediction of both EBV and GEBV. Predictions by Animal Model (traditional EBV) using only domestic first lactation records and GMACE values were correlated by only 0.33. Combining the nation-wide domestic database with all available DRP for genotyped and un-genotyped sires from Interbull resulted in an EBV correlation of 0.60, compared with 0.47 when only Interbull data were used. In all cases, GEBVs had higher correlations than traditional EBVs, and the highest correlations were for predictions from the ssGBLUP procedure using combined data (0.75), or with all available DRP from Interbull records only (one-step blending approach, 0.69). The ssGBLUP predictions using the first three domestic lactation records in the TD model were correlated with GMACE predictions by 0.69, 0.64 and 0.61 for milk yield, protein yield and fat yield, respectively.
Topobathymetric LiDAR point cloud processing and landform classification in a tidal environment
NASA Astrophysics Data System (ADS)
Skovgaard Andersen, Mikkel; Al-Hamdani, Zyad; Steinbacher, Frank; Rolighed Larsen, Laurids; Brandbyge Ernstsen, Verner
2017-04-01
Historically it has been difficult to create high resolution Digital Elevation Models (DEMs) in land-water transition zones due to shallow water depth and often challenging environmental conditions. This gap of information has been reflected as a "white ribbon" with no data in the land-water transition zone. In recent years, the technology of airborne topobathymetric Light Detection and Ranging (LiDAR) has proven capable of filling out the gap by simultaneously capturing topographic and bathymetric elevation information, using only a single green laser. We collected green LiDAR point cloud data in the Knudedyb tidal inlet system in the Danish Wadden Sea in spring 2014. Creating a DEM from a point cloud requires the general processing steps of data filtering, water surface detection and refraction correction. However, there is no transparent and reproducible method for processing green LiDAR data into a DEM, specifically regarding the procedure of water surface detection and modelling. We developed a step-by-step procedure for creating a DEM from raw green LiDAR point cloud data, including a procedure for making a Digital Water Surface Model (DWSM) (see Andersen et al., 2017). Two different classification analyses were applied to the high resolution DEM: A geomorphometric and a morphological classification, respectively. The classification methods were originally developed for a small test area; but in this work, we have used the classification methods to classify the complete Knudedyb tidal inlet system. References Andersen MS, Gergely Á, Al-Hamdani Z, Steinbacher F, Larsen LR, Ernstsen VB (2017). Processing and performance of topobathymetric lidar data for geomorphometric and morphological classification in a high-energy tidal environment. Hydrol. Earth Syst. Sci., 21: 43-63, doi:10.5194/hess-21-43-2017. Acknowledgements This work was funded by the Danish Council for Independent Research | Natural Sciences through the project "Process-based understanding and prediction of morphodynamics in a natural coastal system in response to climate change" (Steno Grant no. 10-081102) and by the Geocenter Denmark through the project "Closing the gap! - Coherent land-water environmental mapping (LAWA)" (Grant no. 4-2015).
76 FR 34801 - Petition for Modification of Single Car Air Brake Test Procedures
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-14
...] Petition for Modification of Single Car Air Brake Test Procedures In accordance with Part 232 of Title 49... Railroad Administration (FRA) grant a modification of the single car air brake test procedures as... of 25 flat cars in consist with revenue cars utilized as locomotives in ``work'' trains, where the...
NASA Astrophysics Data System (ADS)
Trejos, Sorayda; Fredy Barrera, John; Torroba, Roberto
2015-08-01
We present for the first time an optical encrypting-decrypting protocol for recovering messages without speckle noise. This is a digital holographic technique using a 2f scheme to process QR codes entries. In the procedure, letters used to compose eventual messages are individually converted into a QR code, and then each QR code is divided into portions. Through a holographic technique, we store each processed portion. After filtering and repositioning, we add all processed data to create a single pack, thus simplifying the handling and recovery of multiple QR code images, representing the first multiplexing procedure applied to processed QR codes. All QR codes are recovered in a single step and in the same plane, showing neither cross-talk nor noise problems as in other methods. Experiments have been conducted using an interferometric configuration and comparisons between unprocessed and recovered QR codes have been performed, showing differences between them due to the involved processing. Recovered QR codes can be successfully scanned, thanks to their noise tolerance. Finally, the appropriate sequence in the scanning of the recovered QR codes brings a noiseless retrieved message. Additionally, to procure maximum security, the multiplexed pack could be multiplied by a digital diffuser as to encrypt it. The encrypted pack is easily decoded by multiplying the multiplexing with the complex conjugate of the diffuser. As it is a digital operation, no noise is added. Therefore, this technique is threefold robust, involving multiplexing, encryption, and the need of a sequence to retrieve the outcome.
Shrivas, Kamlesh; Wu, Hui-Fen
2008-02-01
A novel, rapid and simple sample pretreatment technique termed ultrasonication followed by single-drop micro-extraction (U-SDME) has been developed and combined with GC/MS for the determination of organochlorine pesticides (OCPs) in fish. In the present work, the lengthy procedures generally used in the conventional methods like, Soxhlet extraction, supercritical fluid extraction, pressurized liquid extraction and microwave assisted solvent extraction for extraction of OCPs from fish tissues are minimized by the use of two simple extraction procedures. Firstly, OCPs from fish were extracted in organic solvent with ultrasonication and then subsequently preconcentrated by single-drop micro-extraction (SDME). Extraction parameters of ultrasonication and SDME were optimized in spiked sample solution in order to obtain efficient extraction of OCPs from fish tissues. The calibration curves for OCPs were found to be linear between 10-1000 ng/g with correlation of estimations in the range 0.990-0.994. The recoveries obtained in blank fish tissues were ranged from 82.1 to 95.3%. The LOD and RSD for determination of OCPs in fish were 0.5 ng/g and 9.4-10.0%, respectively. The proposed method was applied for the determination of bioconcentration factor in fish after exposure to different concentrations of OCPs in cultured water. The present method avoids the co-extraction of lipids, long extraction steps (>12 h) and large amount of organic solvent for the separation of OCPs. The main advantages of the present method are rapid, selective, sensitive and low cost for the determination of OCPs in fish.
Dhir, Vinay; Itoi, Takao; Fockens, Paul; Perez-Miranda, Manuel; Khashab, Mouen A; Seo, Dong Wan; Yang, Ai Ming; Lawrence, Khek Yu; Maydeo, Amit
2015-02-01
EUS-guided biliary drainage (EUS-BD) has emerged as an alternative rescue method in patients with failed ERCP. Opportunities for teaching and training are limited because of a low case volume at most centers. To evaluate a stereolithography/3-dimensional (3D) printing bile duct prototype for teaching and training in EUS-BD. Prospective observational feasibility study. Tertiary referral center. Twenty endosonographers attending an interventional EUS workshop. A prototype of a dilated biliary system was prepared by computer-aided design and 3D printing. The study participants performed guidewire manipulation and EUS-BD procedures (antegrade procedure and/or choledochoduodenostomy) on the prototype. Participants were scored with the device on a scale of 1 to 5 via a questionnaire. Participants' success rate for various steps of the EUS-BD procedure was noted. Subjective and objective evaluation of the prototype regarding its overall applicability, quality of radiographic and EUS images, and 4 steps of EUS-BD procedure (needle puncture, guidewire manipulation, tract dilation, stent placement). Fifteen participants returned the questionnaire, and 10 completed all 4 steps of EUS-BD. The median score for overall utility was 4, whereas that for EUS and US views was 5. Participants with experience in performing more than 20 EUS-BD procedures scored the prototype significantly lower for stent placement (P = .013) and equivalent for needle puncture, tract dilation, and wire manipulation. The success rate of various steps was 100% for needle puncture and tract dilation, 82.35% for wire manipulation, and 80% for stent placement. The mean overall procedure time was 18 minutes. Small number of participants. The 3D printing bile duct prototype appears suitable for teaching of and training in the various steps of EUS-BD. Further studies are required to elucidate its role. Copyright © 2015 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.
A microfluidic approach to parallelized transcriptional profiling of single cells.
Sun, Hao; Olsen, Timothy; Zhu, Jing; Tao, Jianguo; Ponnaiya, Brian; Amundson, Sally A; Brenner, David J; Lin, Qiao
2015-12-01
The ability to correlate single-cell genetic information with cellular phenotypes is of great importance to biology and medicine, as it holds the potential to gain insight into disease pathways that is unavailable from ensemble measurements. We present a microfluidic approach to parallelized, rapid, quantitative analysis of messenger RNA from single cells via RT-qPCR. The approach leverages an array of single-cell RT-qPCR analysis units formed by a set of parallel microchannels concurrently controlled by elastomeric pneumatic valves, thereby enabling parallelized handling and processing of single cells in a drastically simplified operation procedure using a relatively small number of microvalves. All steps for single-cell RT-qPCR, including cell isolation and immobilization, cell lysis, mRNA purification, reverse transcription and qPCR, are integrated on a single chip, eliminating the need for off-chip manual cell and reagent transfer and qPCR amplification as commonly used in existing approaches. Additionally, the approach incorporates optically transparent microfluidic components to allow monitoring of single-cell trapping without the need for molecular labeling that can potentially alter the targeted gene expression and utilizes a polycarbonate film as a barrier against evaporation to minimize the loss of reagents at elevated temperatures during the analysis. We demonstrate the utility of the approach by the transcriptional profiling for the induction of the cyclin-dependent kinase inhibitor 1a and the glyceraldehyde 3-phosphate dehydrogenase in single cells from the MCF-7 breast cancer cell line. Furthermore, the methyl methanesulfonate is employed to allow measurement of the expression of the genes in individual cells responding to a genotoxic stress.
ERIC Educational Resources Information Center
Bancroft, Stacie L.; Weiss, Julie S.; Libby, Myrna E.; Ahearn, William H.
2011-01-01
We compared variations for teaching a sequence of responses through forward chaining. Seven children who had been diagnosed with autism participated in a comparison of teacher completion (TC) of steps beyond the training step and manually guiding the student (SC) to complete steps beyond the training step. A no-completion (NC) condition, in which…
Single Molecule Stepping and Structural Dynamics of Myosin X
Sun, Yujie; Sato, Osamu; Ruhnow, Felix; Arsenault, Mark E.; Ikebe, Mitsuo; Goldman, Yale E.
2010-01-01
Myosin X is an unconventional myosin with puzzling motility properties. We studied the motility of dimerized myosin X using single molecule fluorescence techniques – polTIRF, FIONA, and Parallax to measure rotation angles and 3-dimensional position of the molecule during its walk. It was found that Myosin X steps processively in a hand-over-hand manner following a left-handed helical path along both single actin filaments and bundles. Its step size and velocity are smaller on actin bundles than individual filaments, suggesting myosin X often steps onto neighboring filaments in a bundle. The data suggest that a previously postulated single α-helical domain mechanically extends the 3-IQ motif lever arm and either the neck-tail hinge or the tail is flexible. These structural features, in conjunction with the membrane and microtubule binding domains, enable myosin X to perform multiple functions on varied actin structures in cells. PMID:20364131
Resampling procedures to identify important SNPs using a consensus approach.
Pardy, Christopher; Motyer, Allan; Wilson, Susan
2011-11-29
Our goal is to identify common single-nucleotide polymorphisms (SNPs) (minor allele frequency > 1%) that add predictive accuracy above that gained by knowledge of easily measured clinical variables. We take an algorithmic approach to predict each phenotypic variable using a combination of phenotypic and genotypic predictors. We perform our procedure on the first simulated replicate and then validate against the others. Our procedure performs well when predicting Q1 but is less successful for the other outcomes. We use resampling procedures where possible to guard against false positives and to improve generalizability. The approach is based on finding a consensus regarding important SNPs by applying random forests and the least absolute shrinkage and selection operator (LASSO) on multiple subsamples. Random forests are used first to discard unimportant predictors, narrowing our focus to roughly 100 important SNPs. A cross-validation LASSO is then used to further select variables. We combine these procedures to guarantee that cross-validation can be used to choose a shrinkage parameter for the LASSO. If the clinical variables were unavailable, this prefiltering step would be essential. We perform the SNP-based analyses simultaneously rather than one at a time to estimate SNP effects in the presence of other causal variants. We analyzed the first simulated replicate of Genetic Analysis Workshop 17 without knowledge of the true model. Post-conference knowledge of the simulation parameters allowed us to investigate the limitations of our approach. We found that many of the false positives we identified were substantially correlated with genuine causal SNPs.
Is the learning curve endless? One surgeon's experience with robotic prostatectomy
NASA Astrophysics Data System (ADS)
Patel, Vipul; Thaly, Rahul; Shah, Ketul
2007-02-01
Introduction: After performing 1,000 robotic prostatectomies we reflected back on our experience to determine what defined the learning curve and the essential elements that were the keys to surmounting it. Method: We retrospectively assessed our experience to attempt to define the learning curve(s), key elements of the procedure, technical refinements and changes in technology that facilitated our progress. Result: The initial learning curve to achieve basic competence and the ability to smoothly perform the procedure in less than 4 hours with acceptable outcomes was approximately 25 cases. A second learning curve was present between 75-100 cases as we approached more complicated patients. At 200 cases we were comfortably able to complete the procedure routinely in less than 2.5 hours with no specific step of the procedure hindering our progression. At 500 cases we had the introduction of new instrumentation (4th arm, biopolar Maryland, monopolar scissors) that changed our approach to the bladder neck and neurovascular bundle dissection. The most challenging part of the procedure was the bladder neck dissection. Conclusion: There is no single parameter that can be used to assess or define the learning curve. We used a combination of factors to make our subjective definition this included: operative time, smoothness of technical progression during the case along with clinical outcomes. The further our case experience progressed the more we expected of our outcomes, thus we continually modified our technique and hence embarked upon yet a new learning curve.
Reflectance of vegetation, soil, and water
NASA Technical Reports Server (NTRS)
Wiegand, C. L. (Principal Investigator)
1973-01-01
There are no author-identified significant results in this report. This report deals with the selection of the best channels from the 24-channel aircraft data to represent crop and soil conditions. A three-step procedure has been developed that involves using univariate statistics and an F-ratio test to indicate the best 14 channels. From the 14, the 10 best channels are selected by a multivariate stochastic process. The third step involves the pattern recognition procedures developed in the data analysis plan. Indications are that the procedures in use are satsifactory and will extract the desired information from the data.
The robotic Whipple: operative strategy and technical considerations.
MacKenzie, Shawn; Kosari, Kambiz; Sielaff, Timothy; Johnson, Eric
2011-03-01
Advances in robotic surgery have allowed the frontiers of minimally invasive pancreatic surgery to expand. We present a step-by-step approach to the robotic Whipple procedure. The discussion includes port setting and robotic docking, kocherization and superior mesenteric vein identification, portal dissection, releasing the ligament of Treitz, uncinate dissection, and reconstruction. A brief report of our initial 2-year experience with the robotic Whipple procedure is also presented.
NASA Technical Reports Server (NTRS)
1975-01-01
A general description of the leading edge/flat surface heating array is presented along with its components, assembly instructions, installation instructions, operation procedures, maintenance instructions, repair procedures, schematics, spare parts lists, engineering drawings of the array, and functional acceptance test log sheets. The proper replacement of components, correct torque values, step-by-step maintenance instructions, and pretest checkouts are described.
Single-Shot X-Ray Phase-Contrast Computed Tomography with Nonmicrofocal Laboratory Sources
NASA Astrophysics Data System (ADS)
Diemoz, P. C.; Hagen, C. K.; Endrizzi, M.; Minuti, M.; Bellazzini, R.; Urbani, L.; De Coppi, P.; Olivo, A.
2017-04-01
We present a method that enables performing x-ray phase-contrast imaging (XPCI) computed tomography with a laboratory setup using a single image per projection angle, eliminating the need to move optical elements during acquisition. Theoretical derivation of the method is presented, and its validity conditions are provided. The object is assumed to be quasihomogeneous, i.e., to feature a ratio between the refractive index and the linear attenuation coefficient that is approximately constant across the field of view. The method is experimentally demonstrated on a plastics phantom and on biological samples using a continuous rotation acquisition scheme achieving scan times of a few minutes. Moreover, we show that such acquisition times can be further reduced with the use of a high-efficiency photon-counting detector. Thanks to its ability to substantially simplify the image-acquisition procedure and greatly reduce collection times, we believe this method represents a very important step towards the application of XPCI to real-world problems.
Space Maintenance with an Innovative "Tube and Loop" Space Maintainer (Nikhil Appliance).
Srivastava, Nikhil; Grover, Jyotika; Panthri, Prerna
2016-01-01
Despite the best efforts in prevention, premature loss of primary teeth continues to be a common problem in pediatric dentistry, resulting in disruption of arch integrity and adversely affecting the proper alignment of permanent successors. Space maintainers (SMs) are special appliances used for maintaining space created due to premature loss of primary teeth. Band and loop SM is mostly indicated for the premature loss of single primary molar, but this appliance has a number of limitations both for operators and for patients. Presented in this article is an innovative "Tube and Loop" SM (Nikhil appliance) which offers several advantages over the conventional band and loop SM. It is not only easy and quick to fabricate but can also be completed in a single sitting and cumbersome steps like impression making and laboratory procedures namely soldering are eliminated. How to cite this article: Srivastava N, Grover J, Panthri P. Space Maintenance with an Innovative "Tube and Loop" Space Maintainer (Nikhil Appliance). Int J Clin Pediatr Dent 2016;9(1):86-89.
Salas, Daniela; Borrull, Francesc; Fontanals, Núria; Marcé, Rosa Maria
2018-01-01
The aim of the present study is to broaden the applications of mixed-mode ion-exchange solid-phase extraction sorbents to extract both basic and acidic compounds simultaneously by combining the sorbents in a single cartridge and developing a simplified extraction procedure. Four different cartridges containing negative and positive charges in the same configuration were evaluated and compared to extract a group of basic, neutral, and acidic pharmaceuticals selected as model compounds. After a thorough optimization of the extraction conditions, the four different cartridges showed to be capable of retaining basic and acidic pharmaceuticals simultaneously through ionic interactions, allowing the introduction of a washing step with 15 mL methanol to eliminate interferences retained by hydrophobic interactions. Using the best combined cartridge, a method was developed, validated, and further applied to environmental waters to demonstrate that the method is promising for the extraction of basic and acidic compounds from very complex samples.
Suyama, Yoshihisa; Matsuki, Yu
2015-01-01
Restriction-enzyme (RE)-based next-generation sequencing methods have revolutionized marker-assisted genetic studies; however, the use of REs has limited their widespread adoption, especially in field samples with low-quality DNA and/or small quantities of DNA. Here, we developed a PCR-based procedure to construct reduced representation libraries without RE digestion steps, representing de novo single-nucleotide polymorphism discovery, and its genotyping using next-generation sequencing. Using multiplexed inter-simple sequence repeat (ISSR) primers, thousands of genome-wide regions were amplified effectively from a wide variety of genomes, without prior genetic information. We demonstrated: 1) Mendelian gametic segregation of the discovered variants; 2) reproducibility of genotyping by checking its applicability for individual identification; and 3) applicability in a wide variety of species by checking standard population genetic analysis. This approach, called multiplexed ISSR genotyping by sequencing, should be applicable to many marker-assisted genetic studies with a wide range of DNA qualities and quantities. PMID:26593239
Using single nuclei for RNA-seq to capture the transcriptome of postmortem neurons
Krishnaswami, Suguna Rani; Grindberg, Rashel V; Novotny, Mark; Venepally, Pratap; Lacar, Benjamin; Bhutani, Kunal; Linker, Sara B; Pham, Son; Erwin, Jennifer A; Miller, Jeremy A; Hodge, Rebecca; McCarthy, James K; Kelder, Martin; McCorrison, Jamison; Aevermann, Brian D; Fuertes, Francisco Diez; Scheuermann, Richard H; Lee, Jun; Lein, Ed S; Schork, Nicholas; McConnell, Michael J; Gage, Fred H; Lasken, Roger S
2016-01-01
A protocol is described for sequencing the transcriptome of a cell nucleus. Nuclei are isolated from specimens and sorted by FACS, cDNA libraries are constructed and RNA-seq is performed, followed by data analysis. Some steps follow published methods (Smart-seq2 for cDNA synthesis and Nextera XT barcoded library preparation) and are not described in detail here. Previous single-cell approaches for RNA-seq from tissues include cell dissociation using protease treatment at 30 °C, which is known to alter the transcriptome. We isolate nuclei at 4 °C from tissue homogenates, which cause minimal damage. Nuclear transcriptomes can be obtained from postmortem human brain tissue stored at −80 °C, making brain archives accessible for RNA-seq from individual neurons. The method also allows investigation of biological features unique to nuclei, such as enrichment of certain transcripts and precursors of some noncoding RNAs. By following this procedure, it takes about 4 d to construct cDNA libraries that are ready for sequencing. PMID:26890679
Regis, R R; Alves, C C S; Rocha, S S M; Negreiros, W A; Freitas-Pontes, K M
2016-10-01
The literature has questioned the real need for some clinical and laboratory procedures considered essential for achieving better results for complete denture fabrication. The aim of this study was to review the current literature concerning the relevance of a two-step impression procedure to achieve better clinical results in fabricating conventional complete dentures. Through an electronic search strategy of the PubMed/MEDLINE database, randomised controlled clinical trials which compared complete denture fabrication in adults in which one or two steps of impressions occurred were identified. The selections were made by three independent reviewers. Among the 540 titles initially identified, four studies (seven published papers) reporting on 257 patients evaluating aspects such as oral health-related quality of life, patient satisfaction with dentures in use, masticatory performance and chewing ability, denture quality, direct and indirect costs were considered eligible. The quality of included studies was assessed according to the Cochrane guidelines. The clinical studies considered for this review suggest that a two-step impression procedure may not be mandatory for the success of conventional complete denture fabrication regarding a variety of clinical aspects of denture quality and patients' perceptions of the treatment. © 2016 John Wiley & Sons Ltd.
The Evolution of Utilizing Manual Throttles to Avoid Excessively Low LH2 NPSP at the SSME Inlet
NASA Technical Reports Server (NTRS)
Henfling, Rick
2011-01-01
In the late 1970s, years before the Space Shuttle flew its maiden voyage, it was understood low liquid hydrogen (LH2) Net Positive Suction Pressure (NPSP) at the inlet to the Space Shuttle Main Engine (SSME) could have adverse effects on engine operation. A number of failures within both the External Tank (ET) and the Orbiter Main Propulsion System (MPS) could result in a low LH2 NPSP condition, which at extremely low levels can result in cavitation of SSME turbomachinery. Operational workarounds were developed to take advantage of the onboard crew s ability to manually throttle down the SSMEs (via the Pilot s Speedbrake/Throttle Controller), which alleviated the low LH2 NPSP condition. Manually throttling the SSME to a lower power level resulted in an increase in NPSP, mainly due to the reduction in frictional flow losses while at the lower throttle setting. Early in the Space Shuttle Program s history, the relevant Flight Rule for the Booster flight controllers in Mission Control did not distinguish between ET and Orbiter MPS failures and the same crew action was taken for both. However, after a review of all Booster operational techniques following the Challenger disaster in the late 1980s, it was determined manually throttling the SSME to a lower power was only effective for Orbiter MPS failures and the Flight Rule was updated to reflect this change. The Flight Rule and associated crew actions initially called for a single throttle step to minimum power level when a low threshold for NPSP was met. As engineers refined their understanding of the NPSP requirements for the SSME (through a robust testing program), the operational techniques evolved to take advantage of the additional capabilities. This paper will examine the evolution of the Flight rule and associated procedure and how increases in knowledge about the SSME and the Space Shuttle vehicle as a whole have helped shape their development. What once was a single throttle step when NPSP decreased to a certain threshold has now become three throttle steps, each occurring at a lower NPSP threshold. Additionally the procedure, which for early Space Shuttle missions required a Return-to-Launch-Site abort, now results in a nominal Main Engine Cut Off and no loss of mission objectives.
The Evolution of Utilizing Manual Throttling to Avoid Excessively Low LH2 NPSP at the SSME Inlet
NASA Technical Reports Server (NTRS)
Henfling, Rick
2010-01-01
In the late 1970s, years before the Space Shuttle flew its maiden voyage, it was understood low liquid hydrogen (LH2) Net Positive Suction Pressure (NPSP) at the inlet to the Space Shuttle Main Engine (SSME) could have adverse effects on engine operation. A number of failures within both the External Tank (ET) and the Orbiter Main Propulsion System (MPS) could result in a low LH2 NPSP condition, which at extremely low levels can result in cavitation of SSME turbomachinery. Operational workarounds were developed to take advantage of the onboard crew s ability to manually throttle down the SSMEs (via the Pilot s Speedbrake/Throttle Controller), which alleviated the low LH2 NPSP condition. Manually throttling the SSME to a lower power level resulted in an increase in NPSP, mainly due to the reduction in frictional flow losses while at the lower throttle setting. Early in the Space Shuttle Program s history, the relevant Flight Rule for the Booster flight controller in Mission Control did not distinguish between ET and Orbiter MPS failures and the same crew action was taken for both. However, after a review of all Booster operational techniques following the Challenger disaster in the late 1980s, it was determined manually throttling the SSME to a lower power was only effective for Orbiter MPS failures and the Flight Rule was updated to reflect this change. The Flight Rule and associated crew actions initially called for a single throttle step to minimum power level when a low threshold for NPSP was met. As engineers refined their understanding of the NPSP requirements for the SSME (through a robust testing program), the operational techniques evolved to take advantage of the additional capabilities. This paper will examine the evolution of the Flight rule and associated procedure and how increases in knowledge about the SSME and the Space Shuttle vehicle as a whole have helped shape their development. What once was a single throttle step when NPSP decreased to a certain low threshold has now become three throttle steps, each occurring at a lower NPSP threshold. Additionally the procedure, which for early Space Shuttle missions required a Return-to-Launch-Site abort, now results in a nominal Main Engine Cut Off and no loss of mission objectives.
Step-by-Step Visual Manuals: Design and Development
ERIC Educational Resources Information Center
Urata, Toshiyuki
2004-01-01
The types of handouts and manuals that are used in technology training vary. Some describe procedures in a narrative way without graphics; some employ step-by-step instructions with screen captures. According to Thirlway (1994), a training manual should be like a tutor that permits a student to learn at his own pace and gives him confidence for…
Effects of potassium oxalate on knoop hardness of etch-and-rinse adhesives.
Silva, S M A; Malacarne-Zanon, J; Carvalho, R M; Alves, M C; De Goes, M F; Anido-Anido, A; Carrilho, M R
2012-01-01
The objective of this study was to determine whether the hardness of etch-and-rinse adhesives may be affected by the pretreatment of acid-etched dentin with potassium oxalate desensitizer. Unerupted human third molars were cut into crown segments by removing the occlusal enamel and roots. The pulp chamber of these crown segments was connected to a syringe barrel filled with phosphate-buffered saline so that the moisture of dentin was maintained during the bonding procedures. Three etch-and-rinse adhesives-two two-step systems (Adper Single Bond 2 [SB], One-Step [OS]) and one three-step system (Adper Scotchbond Multi-Purpose [MP])-were applied to acid-etched dentin that had been treated (experimental groups) or not (control groups) with potassium oxalate (BisBlock). The Knoop hardness (KHN) of adhesives was taken at different sites of the outer surface of the adhesive-bonded dentin. The KHN of the three tested adhesives applied to acid-etched dentin treated with potassium oxalate was significantly lower than that exhibited by the respective controls (not treated with oxalate; p<0.05). Regardless of the adhesive, the treatment with potassium oxalate reduced the adhesives' KHN (p<0.05), with the OS system exhibiting the lowest KHN compared with the MP and SB systems.
Highly Sensitive Bacteriophage-Based Detection of Brucella abortus in Mixed Culture and Spiked Blood
Sergueev, Kirill V.; Filippov, Andrey A.; Nikolich, Mikeljon P.
2017-01-01
For decades, bacteriophages (phages) have been used for Brucella species identification in the diagnosis and epidemiology of brucellosis. Traditional Brucella phage typing is a multi-day procedure including the isolation of a pure culture, a step that can take up to three weeks. In this study, we focused on the use of brucellaphages for sensitive detection of the pathogen in clinical and other complex samples, and developed an indirect method of Brucella detection using real-time quantitative PCR monitoring of brucellaphage DNA amplification via replication on live Brucella cells. This assay allowed the detection of single bacteria (down to 1 colony-forming unit per milliliter) within 72 h without DNA extraction and purification steps. The technique was equally efficient with Brucella abortus pure culture and with mixed cultures of B. abortus and α-proteobacterial near neighbors that can be misidentified as Brucella spp., Ochrobactrum anthropi and Afipia felis. The addition of a simple short sample preparation step enabled the indirect phage-based detection of B. abortus in spiked blood, with the same high sensitivity. This indirect phage-based detection assay enables the rapid and sensitive detection of live B. abortus in mixed cultures and in blood samples, and can potentially be applied for detection in other clinical samples and other complex sample types. PMID:28604602
Janiszewski, J; Schneider, P; Hoffmaster, K; Swyden, M; Wells, D; Fouda, H
1997-01-01
The development and application of membrane solid phase extraction (SPE) in 96-well microtiter plate format is described for the automated analysis of drugs in biological fluids. The small bed volume of the membrane allows elution of the analyte in a very small solvent volume, permitting direct HPLC injection and negating the need for the time consuming solvent evaporation step. A programmable liquid handling station (Quadra 96) was modified to automate all SPE steps. To avoid drying of the SPE bed and to enhance the analytical precision a novel protocol for performing the condition, load and wash steps in rapid succession was utilized. A block of 96 samples can now be extracted in 10 min., about 30 times faster than manual solvent extraction or single cartridge SPE methods. This processing speed complements the high-throughput speed of contemporary high performance liquid chromatography mass spectrometry (HPLC/MS) analysis. The quantitative analysis of a test analyte (Ziprasidone) in plasma demonstrates the utility and throughput of membrane SPE in combination with HPLC/MS. The results obtained with the current automated procedure compare favorably with those obtained using solvent and traditional solid phase extraction methods. The method has been used for the analysis of numerous drug prototypes in biological fluids to support drug discovery efforts.
Bouschen, Werner; Schulz, Oliver; Eikel, Daniel; Spengler, Bernhard
2010-02-01
Matrix preparation techniques such as air spraying or vapor deposition were investigated with respect to lateral migration, integration of analyte into matrix crystals and achievable lateral resolution for the purpose of high-resolution biological imaging. The accessible mass range was found to be beyond 5000 u with sufficient analytical sensitivity. Gas-assisted spraying methods (using oxygen-free gases) provide a good compromise between crystal integration of analyte and analyte migration within the sample. Controlling preparational parameters with this method, however, is difficult. Separation of the preparation procedure into two steps, instead, leads to an improved control of migration and incorporation. The first step is a dry vapor deposition of matrix onto the investigated sample. In a second step, incorporation of analyte into the matrix crystal is enhanced by a controlled recrystallization of matrix in a saturated water atmosphere. With this latter method an effective analytical resolution of 2 microm in the x and y direction was achieved for scanning microprobe matrix-assisted laser desorption/ionization imaging mass spectrometry (SMALDI-MS). Cultured A-498 cells of human renal carcinoma were successfully investigated by high-resolution MALDI imaging using the new preparation techniques. Copyright 2010 John Wiley & Sons, Ltd.
Stochastic analysis of particle movement over a dune bed
Lee, Baum K.; Jobson, Harvey E.
1977-01-01
Stochastic models are available that can be used to predict the transport and dispersion of bed-material sediment particles in an alluvial channel. These models are based on the proposition that the movement of a single bed-material sediment particle consists of a series of steps of random length separated by rest periods of random duration and, therefore, application of the models requires a knowledge of the probability distributions of the step lengths, the rest periods, the elevation of particle deposition, and the elevation of particle erosion. The procedure was tested by determining distributions from bed profiles formed in a large laboratory flume with a coarse sand as the bed material. The elevation of particle deposition and the elevation of particle erosion can be considered to be identically distributed, and their distribution can be described by either a ' truncated Gaussian ' or a ' triangular ' density function. The conditional probability distribution of the rest period given the elevation of particle deposition closely followed the two-parameter gamma distribution. The conditional probability distribution of the step length given the elevation of particle erosion and the elevation of particle deposition also closely followed the two-parameter gamma density function. For a given flow, the scale and shape parameters describing the gamma probability distributions can be expressed as functions of bed-elevation. (Woodard-USGS)
Towards Verification of Operational Procedures Using Auto-Generated Diagnostic Trees
NASA Technical Reports Server (NTRS)
Kurtoglu, Tolga; Lutz, Robyn; Patterson-Hine, Ann
2009-01-01
The design, development, and operation of complex space, lunar and planetary exploration systems require the development of general procedures that describe a detailed set of instructions capturing how mission tasks are performed. For both crewed and uncrewed NASA systems, mission safety and the accomplishment of the scientific mission objectives are highly dependent on the correctness of procedures. In this paper, we describe how to use the auto-generated diagnostic trees from existing diagnostic models to improve the verification of standard operating procedures. Specifically, we introduce a systematic method, namely the Diagnostic Tree for Verification (DTV), developed with the goal of leveraging the information contained within auto-generated diagnostic trees in order to check the correctness of procedures, to streamline the procedures in terms of reducing the number of steps or use of resources in them, and to propose alternative procedural steps adaptive to changing operational conditions. The application of the DTV method to a spacecraft electrical power system shows the feasibility of the approach and its range of capabilities
Step by step: Design procedures for stepped chutes
USDA-ARS?s Scientific Manuscript database
The 2013 Farm Bill reaffirms the importance of the investment in America's infrastructure and for the economic growth of our rural communities by authorizing $85 million per year and $250 million in Commodity Credit Corporation funding for watershed rehabilitation through 2018. This investment is e...
Strategies Toward Automation of Overset Structured Surface Grid Generation
NASA Technical Reports Server (NTRS)
Chan, William M.
2017-01-01
An outline of a strategy for automation of overset structured surface grid generation on complex geometries is described. The starting point of the process consists of an unstructured surface triangulation representation of the geometry derived from a native CAD, STEP, or IGES definition, and a set of discretized surface curves that captures all geometric features of interest. The procedure for surface grid generation is decomposed into an algebraic meshing step, a hyperbolic meshing step, and a gap-filling step. This paper will focus primarily on the high-level plan with details on the algebraic step. The algorithmic procedure for the algebraic step involves analyzing the topology of the network of surface curves, distributing grid points appropriately on these curves, identifying domains bounded by four curves that can be meshed algebraically, concatenating the resulting grids into fewer patches, and extending appropriate boundaries of the concatenated grids to provide proper overlap. Results are presented for grids created on various aerospace vehicle components.
Uteng, Marianne; Hauge, Håvard Hildeng; Brondz, Ilia; Nissen-Meyer, Jon; Fimland, Gunnar
2002-01-01
A rapid and simple two-step procedure suitable for both small- and large-scale purification of pediocin-like bacteriocins and other cationic peptides has been developed. In the first step, the bacterial culture was applied directly on a cation-exchange column (1-ml cation exchanger per 100-ml cell culture). Bacteria and anionic compounds passed through the column, and cationic bacteriocins were subsequently eluted with 1 M NaCl. In the second step, the bacteriocin fraction was applied on a low-pressure, reverse-phase column and the bacteriocins were detected as major optical density peaks upon elution with propanol. More than 80% of the activity that was initially in the culture supernatant was recovered in both purification steps, and the final bacteriocin preparation was more than 90% pure as judged by analytical reverse-phase chromatography and capillary electrophoresis. PMID:11823243
Differences in Lower Extremity and Trunk Kinematics between Single Leg Squat and Step Down Tasks
Lewis, Cara L.; Foch, Eric; Luko, Marc M.; Loverro, Kari L.; Khuu, Anne
2015-01-01
The single leg squat and single leg step down are two commonly used functional tasks to assess movement patterns. It is unknown how kinematics compare between these tasks. The purpose of this study was to identify kinematic differences in the lower extremity, pelvis and trunk between the single leg squat and the step down. Fourteen healthy individuals participated in this research and performed the functional tasks while kinematic data were collected for the trunk, pelvis, and lower extremities using a motion capture system. For the single leg squat task, the participant was instructed to squat as low as possible. For the step down task, the participant was instructed to stand on top of a box, slowly lower him/herself until the non-stance heel touched the ground, and return to standing. This was done from two different heights (16cm and 24cm). The kinematics were evaluated at peak knee flexion as well as at 60° of knee flexion. Pearson correlation coefficients (r) between the angles at those two time points were also calculated to better understand the relationship between each task. The tasks resulted in kinematics differences at the knee, hip, pelvis, and trunk at both time points. The single leg squat was performed with less hip adduction (p ≤ 0.003), but more hip external rotation and knee abduction (p ≤ 0.030), than the step down tasks at 60° of knee flexion. These differences were maintained at peak knee flexion except hip external rotation was only significant in the 24cm step down task (p ≤ 0.029). While there were multiple differences between the two step heights at peak knee flexion, the only difference at 60° of knee flexion was in trunk flexion (p < 0.001). Angles at the knee and hip had a moderate to excellent correlation (r = 0.51–0.98), but less consistently so at the pelvis and trunk (r = 0.21–0.96). The differences in movement patterns between the single leg squat and the step down should be considered when selecting a single leg task for evaluation or treatment. The high correlation of knee and hip angles between the three tasks indicates that similar information about knee and hip kinematics was gained from each of these tasks, while pelvis and trunk angles were less well predicted. PMID:25955321